WorldWideScience

Sample records for inhalable aerosol samplers

  1. Evaluation of personal inhalable aerosol samplers with different filters for use during anthrax responses.

    Science.gov (United States)

    Grinshpun, Sergey A; Weber, Angela M; Yermakov, Michael; Indugula, Reshmi; Elmashae, Yousef; Reponen, Tiina; Rose, Laura

    2017-08-01

    Risk of inhalation exposure to viable Bacillus anthracis (B. anthracis) spores has primarily been assessed using short-term, stationary sampling methods which may not accurately characterize the concentration of inhalable-sized spores reaching a person's breathing zone. While a variety of aerosol sampling methods have been utilized during previous anthrax responses, no consensus has yet been established for personal air sampling. The goal of this study was to determine the best sampler-filter combination(s) for the collection and extraction of B. anthracis spores. The study was designed to (1) evaluate the performance of four filter types (one mixed cellulose ester, MCE (pore size = 3 µm), two polytetrafluoroethylene, PTFE (1 and 3 µm), and one polycarbonate, PC (3 µm)); and (2) evaluate the best performing filters in two commercially available inhalable aerosol samplers (IOM and Button). Bacillus thuringiensis kurstaki [Bt(k)], a simulant for B. anthracis, served as the aerosol challenge. The filters were assessed based on criteria such as ability to maintain low pressure drop over an extended sampling period, filter integrity under various environmental conditions, spore collection and extraction efficiencies, ease of loading and unloading the filters into the samplers, cost, and availability. Three of the four tested collection filters-except MCE-were found suitable for efficient collection and recovery of Bt(k) spores sampled from dry and humid as well as dusty and clean air environments for up to 8 hr. The PC (3 µm) filter was identified as the best performing filter in this study. The PTFE (3 µm) demonstrated a comparable performance, but it is more expensive. Slightly higher concentrations were measured with the IOM inhalable sampler which is the preferred sampler's performance criterion when detecting a highly pathogenic agent with no established "safe" inhalation exposure level. Additional studies are needed to address the effects of

  2. A mini-sampler for welding aerosol mounted in close vicinity of the mouth/nose

    International Nuclear Information System (INIS)

    Liden, Goeran; Surakka, Jouni

    2009-01-01

    A small personal aerosol mini-sampler to be used inside modern welding visors has been developed. The main object of the mini-sampler has been to sample manganese. The sampler is based on commercially available 13 mm filter holders but modified to incorporate an inlet nozzle made of aluminium. The nominal flow rate of the mini-sampler is 0,75 l/min. The sampler is to be worn mounted on a headset, modified from professional microphone headsets. The headset mounting arrangement was accepted by the welders. The sampling bias of the mini sampler versus the IOM sampler depends on the coarseness of the sampled aerosol. At the lowest concentration ratio of the open-face 25 mm filter holder to the IOM sampler equal to 0,65, the bias of the mini sampler is approximately -26% versus the IOM. The RMS sampling bias of the mini sampler versus the IOM sampler for manganese is -4,6%. The inhalable fraction of welding aerosol mass consists only of 25-55% of welding fume. The rest of the mass is made up of spatter particles and grinding particles. For manganese generally more than 65% is found in the fume.

  3. Field comparison of three inhalable samplers (IOM, PGP-GSP 3.5 and Button) for welding fumes.

    Science.gov (United States)

    Zugasti, Agurtzane; Montes, Natividad; Rojo, José M; Quintana, M José

    2012-02-01

    Inhalable sampler efficiency depends on the aerodynamic size of the airborne particles to be sampled and the wind speed. The aim of this study was to compare the behaviour of three personal inhalable samplers for welding fumes generated by Manual Metal Arc (MMA) and Metal Active Gas (MAG) processes. The selected samplers were the ones available in Spain when the study began: IOM, PGP-GSP 3.5 (GSP) and Button. Sampling was carried out in a welding training center that provided a homogeneous workplace environment. The static sampling assembly used allowed the placement of 12 samplers and 2 cascade impactors simultaneously. 183 samples were collected throughout 2009 and 2010. The range of welding fumes' mass concentrations was from 2 mg m(-3) to 5 mg m(-3). The pooled variation coefficients for the three inhalable samplers were less than or equal to 3.0%. Welding particle size distribution was characterized by a bimodal log-normal distribution, with MMADs of 0.7 μm and 8.2 μm. For these welding aerosols, the Button and the GSP samplers showed a similar performance (P = 0.598). The mean mass concentration ratio was 1.00 ± 0.01. The IOM sampler showed a different performance (P IOM and 0.92 ± 0.02 for GSP/IOM. This information is useful to consider the measurements accomplished by the IOM, GSP or Button samplers together, in order to assess the exposure at workplaces over time or to study exposure levels in a specific industrial activity, as welding operations.

  4. Sampling Efficiency and Performance of Selected Thoracic Aerosol Samplers.

    Science.gov (United States)

    Görner, Peter; Simon, Xavier; Boivin, Alexis; Bau, Sébastien

    2017-08-01

    Measurement of worker exposure to a thoracic health-related aerosol fraction is necessary in a number of occupational situations. This is the case of workplaces with atmospheres polluted by fibrous particles, such as cotton dust or asbestos, and by particles inducing irritation or bronchoconstriction such as acid mists or flour dust. Three personal and two static thoracic aerosol samplers were tested under laboratory conditions. Sampling efficiency with respect to particle aerodynamic diameter was measured in a horizontal low wind tunnel and in a vertical calm air chamber. Sampling performance was evaluated against conventional thoracic penetration. Three of the tested samplers performed well, when sampling the thoracic aerosol at nominal flow rate and two others performed well at optimized flow rate. The limit of flow rate optimization was found when using cyclone samplers. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  5. Estimation of the Human Extrathoracic Deposition Fraction of Inhaled Particles Using a Polyurethane Foam Collection Substrate in an IOM Sampler

    Directory of Open Access Journals (Sweden)

    Darrah K. Sleeth

    2016-03-01

    Full Text Available Extrathoracic deposition of inhaled particles (i.e., in the head and throat is an important exposure route for many hazardous materials. Current best practices for exposure assessment of aerosols in the workplace involve particle size selective sampling methods based on particle penetration into the human respiratory tract (i.e., inhalable or respirable sampling. However, the International Organization for Standardization (ISO has recently adopted particle deposition sampling conventions (ISO 13138, including conventions for extrathoracic (ET deposition into the anterior nasal passage (ET1 and the posterior nasal and oral passages (ET2. For this study, polyurethane foam was used as a collection substrate inside an inhalable aerosol sampler to provide an estimate of extrathoracic particle deposition. Aerosols of fused aluminum oxide (five sizes, 4.9 µm–44.3 µm were used as a test dust in a low speed (0.2 m/s wind tunnel. Samplers were placed on a rotating mannequin inside the wind tunnel to simulate orientation-averaged personal sampling. Collection efficiency data for the foam insert matched well to the extrathoracic deposition convention for the particle sizes tested. The concept of using a foam insert to match a particle deposition sampling convention was explored in this study and shows promise for future use as a sampling device.

  6. Estimation of the Human Extrathoracic Deposition Fraction of Inhaled Particles Using a Polyurethane Foam Collection Substrate in an IOM Sampler.

    Science.gov (United States)

    Sleeth, Darrah K; Balthaser, Susan A; Collingwood, Scott; Larson, Rodney R

    2016-03-07

    Extrathoracic deposition of inhaled particles (i.e., in the head and throat) is an important exposure route for many hazardous materials. Current best practices for exposure assessment of aerosols in the workplace involve particle size selective sampling methods based on particle penetration into the human respiratory tract (i.e., inhalable or respirable sampling). However, the International Organization for Standardization (ISO) has recently adopted particle deposition sampling conventions (ISO 13138), including conventions for extrathoracic (ET) deposition into the anterior nasal passage (ET₁) and the posterior nasal and oral passages (ET₂). For this study, polyurethane foam was used as a collection substrate inside an inhalable aerosol sampler to provide an estimate of extrathoracic particle deposition. Aerosols of fused aluminum oxide (five sizes, 4.9 µm-44.3 µm) were used as a test dust in a low speed (0.2 m/s) wind tunnel. Samplers were placed on a rotating mannequin inside the wind tunnel to simulate orientation-averaged personal sampling. Collection efficiency data for the foam insert matched well to the extrathoracic deposition convention for the particle sizes tested. The concept of using a foam insert to match a particle deposition sampling convention was explored in this study and shows promise for future use as a sampling device.

  7. Aerosol lung inhalation scintigraphy in normal subjects

    Energy Technology Data Exchange (ETDEWEB)

    Sui, Osamu; Shimazu, Hideki

    1985-03-01

    We previously reported basic and clinical evaluation of aerosol lung inhalation scintigraphy with /sup 99m/Tc-millimicrosphere albumin (milli MISA) and concluded aerosol inhalation scintigraphy with /sup 99m/Tc-milli MISA was useful for routine examination. But central airway deposit of aerosol particles was found in not only the patients with chronic obstructive pulmonary disease (COPD) but also normal subjects. So we performed aerosol inhalation scintigraphy in normal subjects and evaluated their scintigrams. The subjects had normal values of FEVsub(1.0)% (more than 70%) in lung function tests, no abnormal findings in chest X-ray films and no symptoms and signs. The findings of aerosol inhalation scintigrams in them were classified into 3 patterns; type I: homogeneous distribution without central airway deposit, type II: homogeneous distribution with central airway deposit, type III: inhomogeneous distribution. These patterns were compared with lung function tests. There was no significant correlation between type I and type II in lung function tests. Type III was different from type I and type II in inhomogeneous distribution. This finding showed no correlation with %VC, FEVsub(1.0)%, MMF, V radical50 and V radical50/V radical25, but good correlation with V radical25 in a maximum forced expiratory flow-volume curve. Flow-volume curve is one of the sensitive methods in early detection of COPD, so inhomogeneous distribution of type III is considered to be due to small airway dysfunction.

  8. Whole-body nanoparticle aerosol inhalation exposures.

    Science.gov (United States)

    Yi, Jinghai; Chen, Bean T; Schwegler-Berry, Diane; Frazer, Dave; Castranova, Vince; McBride, Carroll; Knuckles, Travis L; Stapleton, Phoebe A; Minarchick, Valerie C; Nurkiewicz, Timothy R

    2013-05-07

    Inhalation is the most likely exposure route for individuals working with aerosolizable engineered nano-materials (ENM). To properly perform nanoparticle inhalation toxicology studies, the aerosols in a chamber housing the experimental animals must have: 1) a steady concentration maintained at a desired level for the entire exposure period; 2) a homogenous composition free of contaminants; and 3) a stable size distribution with a geometric mean diameter generation of aerosols containing nanoparticles is quite challenging because nanoparticles easily agglomerate. This is largely due to very strong inter-particle forces and the formation of large fractal structures in tens or hundreds of microns in size (6), which are difficult to be broken up. Several common aerosol generators, including nebulizers, fluidized beds, Venturi aspirators and the Wright dust feed, were tested; however, none were able to produce nanoparticle aerosols which satisfy all criteria (5). A whole-body nanoparticle aerosol inhalation exposure system was fabricated, validated and utilized for nano-TiO2 inhalation toxicology studies. Critical components: 1) novel nano-TiO2 aerosol generator; 2) 0.5 m(3) whole-body inhalation exposure chamber; and 3) monitor and control system. Nano-TiO2 aerosols generated from bulk dry nano-TiO2 powders (primary diameter of 21 nm, bulk density of 3.8 g/cm(3)) were delivered into the exposure chamber at a flow rate of 90 LPM (10.8 air changes/hr). Particle size distribution and mass concentration profiles were measured continuously with a scanning mobility particle sizer (SMPS), and an electric low pressure impactor (ELPI). The aerosol mass concentration (C) was verified gravimetrically (mg/m(3)). The mass (M) of the collected particles was determined as M = (Mpost-Mpre), where Mpre and Mpost are masses of the filter before and after sampling (mg). The mass concentration was calculated as C = M/(Q*t), where Q is sampling flowrate (m(3)/min), and t is the sampling

  9. Development and evaluation of an ultrasonic personal aerosol sampler.

    Science.gov (United States)

    Volckens, J; Quinn, C; Leith, D; Mehaffy, J; Henry, C S; Miller-Lionberg, D

    2017-03-01

    Assessing personal exposure to air pollution has long proven challenging due to technological limitations posed by the samplers themselves. Historically, wearable aerosol monitors have proven to be expensive, noisy, and burdensome. The objective of this work was to develop a new type of wearable monitor, an ultrasonic personal aerosol sampler (UPAS), to overcome many of the technological limitations in personal exposure assessment. The UPAS is a time-integrated monitor that features a novel micropump that is virtually silent during operation. A suite of onboard environmental sensors integrated with this pump measure and record mass airflow (0.5-3.0 L/min, accurate within 5%), temperature, pressure, relative humidity, light intensity, and acceleration. Rapid development of the UPAS was made possible through recent advances in low-cost electronics, open-source programming platforms, and additive manufacturing for rapid prototyping. Interchangeable cyclone inlets provided a close match to the EPA PM 2.5 mass criterion (within 5%) for device flows at either 1.0 or 2.0 L/min. Battery life varied from 23 to 45 hours depending on sample flow rate and selected filter media. Laboratory tests of the UPAS prototype demonstrate excellent agreement with equivalent federal reference method samplers for gravimetric analysis of PM 2.5 across a broad range of concentrations. © 2016 The Authors. Indoor Air published by John Wiley & Sons Ltd.

  10. Aerosol sampler for analysis of fine and ultrafine aerosols

    Czech Academy of Sciences Publication Activity Database

    Mikuška, Pavel; Čapka, Lukáš; Večeřa, Zbyněk

    2018-01-01

    Roč. 1020 (2018), s. 123-133 ISSN 0003-2670 R&D Projects: GA ČR(CZ) GA14-25558S Institutional support: RVO:68081715 Keywords : atmospheric aerosols * aerosol collection * chemical composition Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 4.950, year: 2016

  11. Performance of prototype high-flow inhalable dust sampler in a livestock production facility.

    Science.gov (United States)

    Anthony, T Renée; Cai, Changjie; Mehaffy, John; Sleeth, Darrah; Volckens, John

    2017-05-01

    A high-flow inhalable sampler, designed for operational flow rates up to 10 L/min using computer simulations and examined in wind tunnel experiments, was evaluated in the field. This prototype sampler was deployed in collocation with an IOM (the benchmark standard sampler) in a swine farrowing building to examine the sampling performance for assessing concentrations of inhalable particulate mass and endotoxin. Paired samplers were deployed for 24 hr on 19 days over a 3-month period. On each sampling day, the paired samplers were deployed at three fixed locations and data were analyzed to identify agreement and to examine systematic biases between concentrations measured by these samplers. Thirty-six paired gravimetric samples were analyzed; insignificant, unsubstantial differences between concentrations were identified between the two samplers (p = 0.16; mean difference 0.03 mg/m 3 ). Forty-four paired samples were available for endotoxin analysis, and a significant (p = 0.001) difference in endotoxin concentration was identified: the prototype sampler, on average, had 120 EU/m 3 more endotoxin than did the IOM samples. Since the same gravimetric samples were analyzed for endotoxin content, the endotoxin difference is likely attributable to differences in endotoxin extraction. The prototype's disposable thin-film polycarbonate capsule was included with the filter in the 1-hr extraction procedure while the internal plastic cassette of the IOM required a rinse procedure that is susceptible to dust losses. Endotoxin concentrations measured with standard plastic IOM inserts that follow this rinsing procedure may underestimate the true endotoxin exposure concentrations. The maximum concentrations in the study (1.55 mg/m 3 gravimetric, 2328 EU/m 3 endotoxin) were lower than other agricultural or industrial environments. Future work should explore the performance of the prototype sampler in dustier environments, where concentrations approach particulates not otherwise

  12. Improving the UNC Passive Aerosol Sampler Model Based on Comparison with Commonly Used Aerosol Sampling Methods.

    Science.gov (United States)

    Shirdel, Mariam; Andersson, Britt M; Bergdahl, Ingvar A; Sommar, Johan N; Wingfors, Håkan; Liljelind, Ingrid E

    2018-03-12

    In an occupational environment, passive sampling could be an alternative to active sampling with pumps for sampling of dust. One passive sampler is the University of North Carolina passive aerosol sampler (UNC sampler). It is often analysed by microscopic imaging. Promising results have been shown for particles above 2.5 µm, but indicate large underestimations for PM2.5. The aim of this study was to evaluate, and possibly improve, the UNC sampler for stationary sampling in a working environment. Sampling was carried out at 8-h intervals during 24 h in four locations in an open pit mine with UNC samplers, respirable cyclones, PM10 and PM2.5 impactors, and an aerodynamic particle sizer (APS). The wind was minimal. For quantification, two modifications of the UNC sampler analysis model, UNC sampler with hybrid model and UNC sampler with area factor, were compared with the original one, UNC sampler with mesh factor derived from wind tunnel experiments. The effect of increased resolution for the microscopic imaging was examined. Use of the area factor and a higher resolution eliminated the underestimation for PM10 and PM2.5. The model with area factor had the overall lowest deviation versus the impactor and the cyclone. The intraclass correlation (ICC) showed that the UNC sampler had a higher precision and better ability to distinguish between different exposure levels compared to the cyclone (ICC: 0.51 versus 0.24), but lower precision compared to the impactor (PM10: 0.79 versus 0.99; PM2.5: 0.30 versus 0.45). The particle size distributions as calculated from the different UNC sampler analysis models were visually compared with the distributions determined by APS. The distributions were obviously different when the UNC sampler with mesh factor was used but came to a reasonable agreement when the area factor was used. High resolution combined with a factor based on area only, results in no underestimation of small particles compared to impactors and cyclones and a

  13. Electrostatics in pharmaceutical aerosols for inhalation.

    Science.gov (United States)

    Wong, Jennifer; Chan, Hak-Kim; Kwok, Philip Chi Lip

    2013-08-01

    Electrostatics continues to play an important role in pharmaceutical aerosols for inhalation. Despite its ubiquitous nature, the charging process is complex and not well understood. Nonetheless, significant advances in the past few years continue to improve understanding and lead to better control of electrostatics. The purpose of this critical review is to present an overview of the literature, with an emphasis on how electrostatic charge can be useful in improving pulmonary drug delivery.

  14. The orientation-averaged aspiration efficiency of IOM-like personal aerosol samplers mounted on bluff bodies.

    Science.gov (United States)

    Paik, Samuel Y; Vincent, James H

    2004-01-01

    This paper describes two sets of experiments that were intended to characterize the orientation-averaged aspiration efficiencies of IOM samplers mounted on rotating bluff bodies. IOM samplers were mounted on simplified, three-dimensional rectangular bluff bodies that were rotated horizontally at a constant rate. Orientation-averaged aspiration efficiencies (A360) were measured as a function of Stokes' number (St), velocity ratio (R) and dimension ratio (r). Aspiration efficiency (A) is the efficiency with which particles are transported from the ambient air into the body of a sampler, and A360 is A averaged over all orientations to the wind. St is a dimensionless variable that represents particle inertia, R is the ratio of the air velocity in the freestream and that at the plane of the sampler's entry orifice, and r is the ratio of the sampler's orifice diameter and the bluff body's width. The first set of experiments were instrumental in establishing a hierarchy of effects on orientation-averaged A. It was clear that compared to r, St had a much larger influence on A. It was also clear, however, that the effects of St were overpowered by the effects of R in many cases. As concluded in previous studies, R and St were considered the most important factors in determining A, even for A360. The second set of experiments investigated A360 of IOM samplers for a much wider range of r than examined in previous research. Two important observations were made from the experimental results. One was that the A360 of IOM samplers, as a function of St, did not change for an r-range of 0.066-0.4. This meant that an IOM sampler mounted on a near life-size mannequin would measure the same aerosol concentration as one not mounted on anything. The second observation was that the aspiration efficiency curve of the IOM sampler was close to the inhalability curve. This gave further evidence that the bluff body did not play a major role in influencing A360, as the IOM samplers, in these

  15. Monitoring of bioaerosol inhalation risks in different environments using a six-stage Andersen sampler and the PCR-DGGE method.

    Science.gov (United States)

    Xu, Zhenqiang; Yao, Maosheng

    2013-05-01

    Increasing evidences show that inhalation of indoor bioaerosols has caused numerous adverse health effects and diseases. However, the bioaerosol size distribution, composition, and concentration level, representing different inhalation risks, could vary with different living environments. The six-stage Andersen sampler is designed to simulate the sampling of different human lung regions. Here, the sampler was used in investigating the bioaerosol exposure in six different environments (student dorm, hospital, laboratory, hotel room, dining hall, and outdoor environment) in Beijing. During the sampling, the Andersen sampler was operated for 30 min for each sample, and three independent experiments were performed for each of the environments. The air samples collected onto each of the six stages of the sampler were incubated on agar plates directly at 26 °C, and the colony forming units (CFU) were manually counted and statistically corrected. In addition, the developed CFUs were washed off the agar plates and subjected to polymerase chain reaction (PCR)-denaturing gradient gel electrophoresis (DGGE) for diversity analysis. Results revealed that for most environments investigated, the culturable bacterial aerosol concentrations were higher than those of culturable fungal aerosols. The culturable bacterial and fungal aerosol fractions, concentration, size distribution, and diversity were shown to vary significantly with the sampling environments. PCR-DGGE analysis indicated that different environments had different culturable bacterial aerosol compositions as revealed by distinct gel band patterns. For most environments tested, larger (>3 μm) culturable bacterial aerosols with a skewed size distribution were shown to prevail, accounting for more than 60 %, while for culturable fungal aerosols with a normal size distribution, those 2.1-4.7 μm dominated, accounting for 20-40 %. Alternaria, Cladosporium, Chaetomium, and Aspergillus were found abundant in most

  16. Relationships between Personal Measurements of 'Total' Dust, Respirable, Thoracic, and Inhalable Aerosol Fractions in the Cement Production Industry.

    Science.gov (United States)

    Notø, Hilde P; Nordby, Karl-Christian; Eduard, Wijnand

    2016-05-01

    The aims of this study were to examine the relationships and establish conversion factors between 'total' dust, respirable, thoracic, and inhalable aerosol fractions measured by parallel personal sampling on workers from the production departments of cement plants. 'Total' dust in this study refers to aerosol sampled by the closed face 37-mm Millipore filter cassette. Side-by-side personal measurements of 'total' dust and respirable, thoracic, and inhalable aerosol fractions were performed on workers in 17 European and Turkish cement plants. Simple linear and mixed model regressions were used to model the associations between the samplers. The total number of personal samples collected on 141 workers was 512. Of these 8.4% were excluded leaving 469 for statistical analysis. The different aerosol fractions contained from 90 to 130 measurements and-side-by side measurements of all four aerosol fractions were collected on 72 workers.The median ratios between observed results of the respirable, 'total' dust, and inhalable fractions relative to the thoracic aerosol fractions were 0.51, 2.4, and 5.9 respectively. The ratios between the samplers were not constant over the measured concentration range and were best described by regression models. Job type, position of samplers on left or right shoulder and plant had no substantial effect on the ratios. The ratios between aerosol fractions changed with different air concentrations. Conversion models for estimation of the fractions were established. These models explained a high proportion of the variance (74-91%) indicating that they are useful for the estimation of concentrations based on measurements of a different aerosol fraction. The calculated uncertainties at most observed concentrations were below 30% which is acceptable for comparison with limit values (EN 482, 2012). The cement industry will therefore be able to predict the health related aerosol fractions from their former or future measurements of one of the

  17. Fatal accidental inhalation of brake cleaner aerosols.

    Science.gov (United States)

    Veit, F; Martz, W; Birngruber, C G; Dettmeyer, R B

    2018-04-23

    Brake cleaner liquid is commonly used for cleaning of engines and motor parts. The commercially available products usually contain mainly volatile organic compounds. As a consequence brake cleaner evaporates fast and almost completely from the cleaned surface. This case report presents a fatal accidental inhalation of brake cleaner liquid aerosols due to the attempted cleaning of a boat engine. A 16year old boy was found lifeless in the engine compartment of a boat engine. In close proximity to the body, the police found cleanings wipes soaked with brake cleaner as well as a pump spray bottle filled with brake cleaner. Essentially the autopsy revealed a cerebral oedema with encephalomalacia, no coagulated blood as well as increased blood and tissue fluid content of the lung. Toxicological analysis revealed brake cleaner fluid in the lung, gastric content and heart blood. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Intersampler field comparison of Respicon(R), IOM, and closed-face 25-mm personal aerosol samplers during primary production of aluminium.

    Science.gov (United States)

    Skaugset, Nils Petter; Ellingsen, Dag G; Notø, Hilde; Jordbekken, Lars; Thomassen, Yngvar

    2013-10-01

    Intersampler field comparison of Respicon(®), 25-mm closed-face 'total dust' cassette (CFC), and IOM inhalable aerosol sampler was conducted in pot rooms at seven aluminium smelters. The aerosol mass and water-soluble fluoride were selected as airborne contaminants for the comparisons. The aerosol masses of 889 sample pairs of IOM and Respicon(®) inhalable aerosol sub-fraction, 165 of IOM and 25-mm CFC, and 194 of CFC and Respicon(®) thoracic aerosol sub-fraction were compared. The number of sample pairs for the comparison of water-soluble fluoride was 906, 170, and 195, respectively. The geometric mean aerosol mass collected with the inhalable Respicon(®) was 2.91 mg m(-3) compared with 3.38 mg m(-3) with the IOM. The overall ratio between IOM and Respicon(®) inhalable sub-fraction was 1.16 [95% confidence interval (CI) = 1.11-1.21] for aerosol mass and 1.13 (95% CI = 1.08-1.18) for water-soluble fluoride. The results indicate that Respicon(®) undersampled the aerosol mass and water-soluble fluoride in the inhalable sub-fraction compared with the IOM. The results indicated undersampling of the Respicon(®) at mass concentrations higher than 1.35 mg m(-3) and oversampling at lower mass concentrations. The overall ratio between aerosol mass collected with IOM and CFC was 4.19 (95% CI = 3.79-4.64) and 1.61 (95% CI = 1.51-1.72) for water-soluble fluoride. Thus, for this industry, a correction factor of 4.2 is suggested for the conversion of CFC to inhalable aerosol masses and a conversion factor of 1.6 for water-soluble fluoride if wall deposits in the CFC are included. CFC and thoracic Respicon(®) collected similar aerosol masses (ratio = 1.04; 95% CI = 0.97-1.12), whereas the ratio was 1.19 (95% CI = 1.11-1.28) for water-soluble fluoride. The variability of the exposure is substantial; thus, large data sets are required in sampler performance field comparisons.

  19. Difference in inhaled aerosol deposition patterns in the lungs due to three different sized aerosols

    International Nuclear Information System (INIS)

    Miki, M.; Isawa, T.; Teshima, T.; Anazawa, Y.; Motomiya, M.

    1992-01-01

    Deposition patterns of inhaled aerosol in the lungs were studied in five normal subjects and 20 patients with lung disease by inhaling radioaerosols with three different particle size distributions. Particle size distributions were 0.84, 1.04 and 1.93 μm in activity median aerodynamic diameter (AMAD) with its geometric standard deviation (σg) of 1.73, 1.71 and 1.52, respectively. Deposition patterns of inhaled aerosols were compared qualitatively and quantitatively by studying six different parameters: alveolar deposition ratio (ALDR), X max , X mean , standard deviation (S.D.), skewness and kurtosis of the radioactive distribution in the lungs following inhalation. It has been found that aerosol deposition patterns varied with particle size. The unevenness of aerosol deposition, X max , X mean and the number of 'hot spots' became more prominent with increase in particle size, whereas values of ALDR and S.D. decreased as particle size increased. (author)

  20. A new sampler for simulating aerosol deposition in the respiratory tract

    International Nuclear Information System (INIS)

    Li Dehong; Zhuo Weihai; Yi Yanling; Chen Bo; Liu Haikuan

    2008-01-01

    For estimation of the deposition fractions of radon progeny in different regions of the respiratory tract, a new sampler consisting of three different configurations of sampling heads was developed. The deposition fractions of aerosols on the wire screens inside the sampling heads were calculated with the fan model of filtration theory. The deposition fractions of aerosols in different regions of the respiratory tract were calculated with the lung dose evaluation program (LUDEP) developed by National Radiological Protection Board (NRPB) as references. In general indoor and mine environments, the deviation between the deposition fractions of attached aerosol on the wire screens designed in this study and its reference values in the respiratory tract is less than 5%. It is possible to accurately estimate the deposition fractions of radon progeny in different regions of the respiratory tract through mimic measurements of radon progeny collected with the new sampler. (authors)

  1. Microfluidic Air Sampler for Highly Efficient Bacterial Aerosol Collection and Identification.

    Science.gov (United States)

    Bian, Xiaojun; Lan, Ying; Wang, Bing; Zhang, Yu Shrike; Liu, Baohong; Yang, Pengyuan; Zhang, Weijia; Qiao, Liang

    2016-12-06

    The early warning capability of the presence of biological aerosol threats is an urgent demand in ensuing civilian and military safety. Efficient and rapid air sample collection in relevant indoor or outdoor environment is a key step for subsequent analysis of airborne microorganisms. Herein, we report a portable battery-powered sampler that is capable of highly efficient bioaerosol collection. The essential module of the sampler is a polydimethylsiloxane (PDMS) microfluidic chip, which consisted of a 3-loop double-spiral microchannel featuring embedded herringbone and sawtooth wave-shaped structures. Vibrio parahemolyticus (V. parahemolyticus) as a model microorganism, was initially employed to validate the bioaerosol collection performance of the device. Results showed that the sampling efficacy reached as high as >99.9%. The microfluidic sampler showed greatly improved capturing efficiency compared with traditional plate sedimentation methods. The high performance of our device was attributed to the horizontal inertial centrifugal force and the vertical turbulence applied to airflow during sampling. The centrifugation field and turbulence were generated by the specially designed herringbone structures when air circulated in the double-spiral microchannel. The sawtooth wave-shaped microstructure created larger specific surface area for accommodating more aerosols. Furthermore, a mixture of bacterial aerosols formed by V. parahemolyticus, Listeria monocytogenes, and Escherichia coli was extracted by the microfluidic sampler. Subsequent integration with mass spectrometry conveniently identified the multiple bacterial species captured by the sampler. Our developed stand-alone and cable-free sampler shows clear advantages comparing with conventional strategies, including portability, easy-to-use, and low cost, indicating great potential in future field applications.

  2. A Pilot Study: The UNC Passive Aerosol Sampler in a Working Environment.

    Science.gov (United States)

    Shirdel, Mariam; Wingfors, Håkan; Andersson, Britt M; Sommar, Johan N; Bergdahl, Ingvar A; Liljelind, Ingrid E

    2017-10-01

    Dust is generally sampled on a filter using air pumps, but passive sampling could be a cost-effective alternative. One promising passive sampler is the University of North Carolina passive aerosol sampler (UNC sampler). The aim of this study is to characterize and compare the UNC sampler's performance with PM10 and PM2.5 impactors in a working environment. Area sampling was carried out at different mining locations using UNC samplers in parallel with PM2.5 and PM10 impactors. Two different collection surfaces, polycarbonate (PC) and carbon tabs (CT), were employed for the UNC sampling. Sampling was carried out for 4-25 hours. The UNC samplers underestimated the concentrations compared to PM10 and PM2.5 impactor data. At the location with the highest aerosol concentration, the time-averaged mean of PC showed 24% and CT 35% of the impactor result for PM2.5. For PM10, it was 39% with PC and 58% with CT. Sample blank values differed between PC and CT. For PM2.5, PC blank values were ~7 times higher than those of CT, but only 1.8 times higher for PM10. The blank variations were larger for PC than for CT. Particle mass concentrations appear to be underestimated by the UNC sampler compared to impactors, more so for PM2.5 than for PM10. CT may be preferred as a collection surface because the blank values were lower and less variable than for PC. Future validations in the working environment should include respirable dust sampling. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  3. Aerosol lung inhalation scintigraphy in children with bronchial asthma

    International Nuclear Information System (INIS)

    Torii, Yoshikuni; Nakayama, Chikashi; Nakata, Hajime; Takahashi, Satomi; Tanaka, Masaaki; Koori, Tateo

    1988-01-01

    Aerosol lung inhalation scintigraphies performed on 37 children with bronchial asthma during asymptomatic periods were evaluated. The findings of their aerosol lung inhalation scintigrams were classified into 4 patterns, as type I: homogeneous distribution without hot spot formation, type II: peripheral homogeneity with central hot spot formation, type IIID (-): inhomogeneous distribution with hot spot formation, but without defect, and type IIID (+): with defect. These aerosol patterns were compared with those of previously reported adult cases and with the severity of bronchial asthma. Normal pattern of type I was found in 5 cases (12%) of our infantile asthmatics in contrast to previously reported adult cases, in which none of normal pattern was found. There were differences between type II and type III in both distribution and disappearance time of hot spot, which indicated that the two types differed from each other in radioaerosol deposition mechanism. There was no significant correlation between type I and type II in the severity of asthma and the frequency of asthmatic attack. Type II may be clinically considered to be the same type as type I. There is the statistically significant difference between type I, II and type III in the frequency of asthmatic attack, but not in the severity of asthma, although most of serious cases showed type III. Aerosol lung inhalation scintigraphy is a useful examination for children with bronchial asthma in which lung function tests may be difficult to perform. (author)

  4. Characteristics and Sampling Efficiencies of Two Personal Aerosol Samplers

    Science.gov (United States)

    2007-07-01

    stainless steel and plastic; therefore, it can be decontaminated easily by immersing in decontamination solution. 9 PAS-2 PAS-1 Figure 3. Picture of PAS...portable, and easy to use for decontamination . The sampling efficiency tests were conducted with monodisperse 0.5-, 1-, and 2.1-gtm fluorescent...Scientific, Corp., Palo Alto, CA). The PSL aerosols were generated using a 24 jet Collison nebulizer and then passed through a radioactive isotope (Kr-85

  5. In vitro tests for aerosol deposition. III: effect of inhaler insertion angle on aerosol deposition.

    Science.gov (United States)

    Delvadia, Renish R; Longest, P Worth; Hindle, Michael; Byron, Peter R

    2013-06-01

    Inhaler orientation with respect to a patient's mouth may be an important variable determining the efficiency of aerosol lung delivery. The effect of insertion angle on regional deposition was evaluated for a series of inhalers using concurrent in vitro and computational fluid dynamics (CFD) analysis. Geometrically realistic physical mouth-throat (MT) and upper tracheobronchial (TB) models were constructed to connect different inhalers at a series of insertion angles relative to the horizontal plane of the model. These models were used to assess albuterol sulfate deposition from the Novolizer(®) dry powder inhaler (DPI), Proventil(®) HFA pressurized metered dose inhaler (MDI), and Respimat(®) Soft Mist™ Inhaler (SMI) following the actuation of a single dose. Drug deposition from Novolizer DPI was studied for Salbulin(®) and an experimental "drug only" formulation. Albuterol sulfate was recovered and quantified from the device and the MT and TB regions. Significant differences in MT and total lung dose (TLD) of albuterol sulfate deposition were not observed for Salbulin Novolizer DPI and Respimat SMI inserted at different angles. In contrast, drug-only Novolizer DPI and Proventil HFA MDI showed a significant difference in MT and TLD deposition using different insertion angles. For drug-only Novolizer DPI and Proventil HFA MDI, the lowest and the highest MT depositions were observed at +10° and -20°, respectively; for Respimat SMI and Salbulin Novolizer DPI, these angles were -10° and +10°, and +20° and -20°, respectively. CFD simulations were in agreement with the experimental results and illustrated shifts in local particle deposition associated with changes in insertion angle. The effect of inhaler orientation at the inhaler-mouth interface on MT aerosol deposition appeared to be dependent on velocity, aerosol size, and formulation. These findings not only demonstrate the need for patient education on correct inhaler orientation, but provide important

  6. Design and application of a new modular adapter for laser diffraction characterization of inhalation aerosols

    NARCIS (Netherlands)

    de Boer, Anne; Gjaltema, D; Hagedoorn, P; Schaller, M; Witt, W; Frijlink, H W

    2002-01-01

    An inhaler adapter has been designed for the characterization of the aerosol clouds from medical aerosol generators such as nebulizers, dry powder inhalers (dpis) and metered dose inhalers (mdis) with laser diffraction technology. The adapter has a pre-separator, for separation of large particles

  7. ''Inhalation lung imaging with radioactive aerosols and gases''

    International Nuclear Information System (INIS)

    Taplin, G.V.; Chopra, S.K.

    1977-01-01

    Lung imaging procedures, performed after the inhalation of /sup 99m/Tc labeled aerosols, 133 Xe and /sup 81m/Kr gases, were used to visualize the sites of airway obstruction and regional abnormalities of ventilatory function in normal volunteers, patients with obstructive airway disease, and pulmonary embolism suspects. Comparisons were made of three methods regarding their functional significance, diagnostic merits, and limitations. A new nebulizer-radioaerosol delivery system is described

  8. Bronchospasm and anaphylactic shock following lidocaine aerosol inhalation in a patient with butane inhalation lung injury.

    Science.gov (United States)

    Lee, Min-Young; Park, Kyong Ah; Yeo, So-Jeong; Kim, Shin-Hee; Goong, Hyeun-Jeong; Jang, An-Soo; Park, Choon-Sik

    2011-10-01

    Allergic reactions to local anesthetics are very rare and represent inhalation lung injury due to butane gas fuel. On the fifth day, he developed an asthmatic attack and anaphylactic shock immediately after lidocaine aerosol administration to prepare for bronchoscopy to confirm an acute inhalational lung injury diagnosis. Cardiopulmonary resuscitation was performed immediately after respiratory arrest, and the patient was admitted to the intensive care unit intubated and on a ventilator. He was extubated safely on the third post-cardiopulmonary resuscitation day. These observations suggest that aerosol lidocaine anesthesia may cause airway narrowing and anaphylactic shock. Practitioners should be aware of this potential complication. We report on this case with a brief review of the literature.

  9. Generation and characterization of cyclosporine aerosols for administration by inhalation

    International Nuclear Information System (INIS)

    Hoover, M.D.; Muggenburg, B.A.; Snipes, M.B.; Wolff, R.K.; Yeh, H.C.; Griffith, B.P.; Burckart, G.J.; Mauderly, J.L.

    1988-01-01

    A method was developed for generating aerosols of the immunosuppressive agent cyclosporine and a gamma-emitting radiolabel ( 99m Tc) for administration by inhalation. Cyclosporine was dissolved in ethyl alcohol (EtOH) and nebulized with a Love- lace nebulizer operated with 50 psi compressed air. For a cyclosporine concentration of 25 mg/mL, the particle size of the aerosol was 0.7 μm activity median aerodynamic diameter (AMAD), with 1.8 geometric standard deviation (GSD). The clear solution of EtOH and cyclosporine became a cloudy suspension when a limited amount of saline solution containing a 99m Tc radiolabel was added. This occurred because cyclosporine is hydrophobic. If saline concentrations as high as 6% in EtOH by volume were used, a gummy residue formed in the nebulizer and the particle aerodynamic diameter became unacceptably large (4.7 μm). When the saline concentration was only 3 % (the minimum radiolabel volume needed for gamma camera studies of lung deposition), the suspensions of cyclosporine could be nebulized to give a particle size of 2.2 μm AMAD with 2.1 GSD. The radiolabel was uniformly distributed with the spherical cyclosporine particles. Concentrations and particle size distributions remained constant over 1-h generation periods. These aerosols have been used in inhalation studies with Beagle dogs. (author)

  10. Physicochemical characteristics of chlorofluorohydrocarbon-based inhalation aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Ashurst, I C

    1985-01-01

    The aim of this work was to gain a better understanding of the physicochemical factors which affect the formulation of suspension inhalation aerosols. The adsorption of six nonionic and cationic surfactants onto Spherisorb has been investigated. The results were analyzed by calculating the area occupied by one adsorbed molecule at the surface and by comparing these values for each surfactant. The amount of each surfactant adsorbed was correlated with the number of sites on that surfactant molecule which could interact with the surface. The stability of suspensions, produced by both the model colloid Spherisorb, and by the drug isoprenaline sulfate, after adsorption of the surfactants, has been assessed by measuring settling times and rising times. The most stable suspension were found to be those which had the greatest amounts of long chain fatty acid surfactant adsorbed on their surface. A comparison was made between the effective stabilizing properties of Span 85 and oleic acid on various drug suspension. It was found that Span 85 gave the most stable suspension. Inhalation aerosol suspensions of isoprenaline sulfate were manufactured using the same surfactants used in the adsorption and suspension stability studies and were analyzed by measuring the particle size distributions of the suspension and the emitted doses. The results were found to correlate with the adsorption and suspension stability studies and it was concluded that a deflocculated suspension was preferable to a flocculated suspension in inhalation aerosols provided that the drug density was less than the propellant density. The application of this work to preformulation studies was also discussed.

  11. Study on the deposition patterns of aerosol inhalation scintigraphy, 2

    International Nuclear Information System (INIS)

    Watanabe, Hiroyuki

    1989-01-01

    The superimposed images obtained by the SPECT of aeresol inhalation scintigraphy and chest CT were applied in 7 cases of diffuse panbronchiolitis. Aerosol deposition patterns were examined, and hot spots were compared with bronchial morphological abnormalities. The results were as follows: 1. Nevertheless, aerosol deposition patterns were characterized by defects of the depositions in the outer zone and hot spots in the inner zone, hot spots distributed from the inner zone to the outer zone. 2. Hot spots and bronchial morphological abnormalities were markedly matched in the inner zone; however, they were mismatched in the outer zone. I concluded that the mechanisms of hot spot formation in the inner zone were different from those in the outer zone. (author)

  12. Deposition of inhaled LMFBR-fuel-sodium aerosols in beagle dogs

    International Nuclear Information System (INIS)

    Hackett, P.L.; Mahlum, D.D.; Briant, J.K.; Catt, D.L.; Peters, L.R.; Clary, A.J.

    1980-01-01

    Initial alveolar deposition of LMFBR-fuel aerosols in beagle dogs amounted to 30% of the inhaled activity, but only 5% of the total inhaled activity was deposited in dogs exposed to sodium-fuel aerosols. Aerosol deposition in the gastrointestinal tract amounted to 4% of the initial body burden of fuel-aerosol exposed dogs and 24% of the burden of animals receiving sodium-fuel aerosols. Preliminary analytical data for the dog exposures appear to agree with rodent data for deposition and distribution patterns of aerosols of similar sodium: fuel ratios

  13. A recirculation aerosol wind tunnel for evaluating aerosol samplers and measuring particle penetration through protective clothing materials.

    Science.gov (United States)

    Jaques, Peter A; Hsiao, Ta-Chih; Gao, Pengfei

    2011-08-01

    A recirculation aerosol wind tunnel was designed to maintain a uniform airflow and stable aerosol size distribution for evaluating aerosol sampler performance and determining particle penetration through protective clothing materials. The oval-shaped wind tunnel was designed to be small enough to fit onto a lab bench, have optimized dimensions for uniformity in wind speed and particle size distributions, sufficient mixing for even distribution of particles, and minimum particle losses. Performance evaluation demonstrates a relatively high level of spatial uniformity, with a coefficient of variation of 1.5-6.2% for wind velocities between 0.4 and 2.8 m s(-1) and, in this range, 0.8-8.5% for particles between 50 and 450 nm. Aerosol concentration stabilized within the first 5-20 min with, approximately, a count median diameter of 135 nm and geometric standard deviation of 2.20. Negligible agglomerate growth and particle loss are suggested. The recirculation design appears to result in unique features as needed for our research.

  14. Experimental study of contamination by inhalation of radioactive iodine aerosols. Biological balance; Etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif bilan biologique

    Energy Technology Data Exchange (ETDEWEB)

    Marble, G [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    Several articles have been published concerning research into contamination produced by inhalation of radioactive iodine aerosols in monkeys. Results dealing with the biological balance of this contamination are presented and discussed in this report. (author) [French] L'etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif effectuee chez le singe a fait l'objet de plusieurs publications. Les resultats concernant le bilan biologique de cette contamination sont presentes et discutes dans ce rapport. (auteur)

  15. Experiment of aerosol-release time for a novel automatic metered dose inhaler

    OpenAIRE

    Mingrong Zhang; Songhao Wang; Yu-Ching Yang

    2016-01-01

    The objective of this study was to evaluate the aerosol-release time in the development of a new automatic adapter for metered dose inhaler. With this device, regular manually operated metered dose inhalers become automatic. During the study, an inhalation simulator was designed and tested with the newly developed mechatronic system. By adjusting the volume and the pressure of the vacuum tank, most human inhalation waveforms were able to simulate. As an example, regular quick-deep and slow-de...

  16. Development and evaluation of an impactor sampler for radioactive aerosol particles

    International Nuclear Information System (INIS)

    Sorimachi, Atsuyuki; Kranrod, Chutima; Chantrarayotha, Supitcha; Tokonami, Shinji

    2008-01-01

    This sampler consists of one impaction stage, which allows separation of airborne particles by 1 μm particle size cut-off point with a 50% probability of impaction, followed by a back-up filter at a flow rate of 1 L min -1 . The particles size more than and less than 1 μm-diameter are collected on the impactor plate at the nozzle side and on the filter, respectively. A Cr-39 detector is mounted on the filter sides of the impaction plate; α particles emitted from the particles less than 1 μm-diameter are counted with the Cr-39 detectors. In order to separate α particles emitted from radon, thoron and their progeny, the Cr-39 detectors are covered with aluminum-vaporized Mylar films. The total thickness of films is adjusted to let their α particles impinge on the Cr-39 detectors. Laboratory tests are going on in terms of the spectral characteristics of α particles before and after passing through the films, the count rate performance of Cr-39 detectors by α particles, the actual collection efficiency of aerosol particles on the impaction plate, and so on. This sampler may be able to supply us with an interesting technique for measuring radon and thoron progeny come from the sources of natural radiation such as the naturally occurred radioactive materials. (author)

  17. Evaluation of expectoration using aerosol inhalation cine-scintigraphy, 2

    International Nuclear Information System (INIS)

    Ohnuki, Masahiro

    1986-01-01

    Postural drainage and mechanical vibration have been evaluated in 16 patients of stable chronic obstructive pulmonary diseases with copious sputum (daily sputum volume > 50 ml) using aerosol cine-scintigraphy. After inhalation of a 99m Tc-Milli MISA aerosol, the removal of radioactivity from total lung field and selected peripheral lung region was measured during 40 min of (1) resting in the upright position (control), (2) postural drainage (PD), (3) postural drainage with mechanical vibration (PDWV). Compared with the control run, PD significantly improved of mucus clearance on the total lung field (p < 0.001 ∼ 0.01) and peripheral lung region (p < 0.001). However, there was no significant difference between PD and PDWV. Abnormal mucus movement was often recognized, such as stasis at the first carina, main bronchus and trachea, wandering to the lower lung (22.7 %) and regurgitation in the lower lung (50.0 %). The study indicated that postural drainage is an effective form, but mechanical vibration is of no value as an adjunct to postural drainage in the treatment of patients with stable chronic obstructive pulmonary diseases, and it was suggested that there is an adverse effect of postural drainage in the lower lung portion. (author)

  18. Experiment of aerosol-release time for a novel automatic metered dose inhaler

    Directory of Open Access Journals (Sweden)

    Mingrong Zhang

    2016-05-01

    Full Text Available The objective of this study was to evaluate the aerosol-release time in the development of a new automatic adapter for metered dose inhaler. With this device, regular manually operated metered dose inhalers become automatic. During the study, an inhalation simulator was designed and tested with the newly developed mechatronic system. By adjusting the volume and the pressure of the vacuum tank, most human inhalation waveforms were able to simulate. As an example, regular quick-deep and slow-deep waveforms were matched within reasonable accuracy. Finally, with the help of dynamic image processing, the aerosol-release time (Tr was carefully measured and fully discussed, including the switch-on time (Ts, the mechatronics-hysteresis (Tm and the intentional-delay (Ti. Under slow-deep inhalation condition which is suitable for metered dose inhaler medicine delivery, the switch-on flow-rate could reach as low as 10 L/min, and the corresponding switch-on time was approximately 0.20 s. While the mechatronics-hysteresis depended on the brand of metered dose inhaler, assuming there was no intentional-delay, the aerosol-release time could be as low as 0.40 and 0.60 s, respectively, for two commercially available metered dose inhalers studied in this article. Therefore, this newly developed mechatronic adapter system could ensure aerosol-release time (Tr within satisfactory range for metered dose inhalers.

  19. Experimental study of contamination by inhalation of radioactive iodine aerosols. Biological balance

    International Nuclear Information System (INIS)

    Marble, G.

    1968-01-01

    Several articles have been published concerning research into contamination produced by inhalation of radioactive iodine aerosols in monkeys. Results dealing with the biological balance of this contamination are presented and discussed in this report. (author) [fr

  20. ANALYSIS OF RESPIRATORY DEPOSITION OF INHALED AMBIENT AEROSOLS FOR DIFFERENT DOSE METRICS

    Science.gov (United States)

    ANALYSIS OF RESPIRATORY DEPOSITION OF INHALED AMBIENT AEROSOLS FOR DIFFERENT DOSE METRICS.Chong S. Kim, SC. Hu**, PA Jaques*, US EPA, National Health and Environmental Effects Research Laboratory, Research Triangle Park, NC 27711; **IIT Research Institute, Chicago, IL; *South...

  1. ANALYSIS OF RESPIRATORY DESPOSITION DOSE OF INHALED AMBIENT AEROSOLS FOR DIFFERENT SIZE FRACTIONS

    Science.gov (United States)

    ANALYSIS OF RESPIRATORY DEPOSITION DOSE OF INHALED AMBIENT AEROSOLS FOR DIFFERENT SIZE FRACTIONS. Chong S. Kim, SC. Hu**, PA Jaques*, US EPA, National Health and Environmental Effects Research Laboratory, Research Triangle Park, NC 27711; **IIT Research Institute, Chicago, IL; *S...

  2. Unevenness on aerosol inhalation lung images and lung function

    International Nuclear Information System (INIS)

    Teshima, Takeo; Isawa, Toyoharu; Hirano, Tomio; Ebina, Akio; Shiraishi, Koichiro; Konno, Kiyoshi

    1985-01-01

    The unevenness or inhomogeneity of aerosol deposition patterns on radioaerosol inhalation lung images has been interpreted rather qualitatively in the clinical practice. We have reported our approach to quantitatively analyze the radioactive count distribution on radioaerosol inhalation lung images in relation to the actual lung function data. We have defined multiple indexes to express the shape and the unevenness of the count distribution of the lung images. To reduce as much as possible the number of indexes to be used in the regression functions, the method of selection of variables was introduced to the multiple regression analysis. Because some variables showed greater coefficients of simple correlation, while others did not, multicollinearity of variables had to be taken into consideration. For this reason, we chose a principal components regression analysis. The multiple regression function for each item of pulmonary function data thus established from analysis of 67 subjects appeared usable as a predictor of the actual lung function: for example, % VC (vital capacity) could be estimated by using four indexes out of the multiple ones with a coefficient of multiple correlation (R) of 0.753, and FEVsub(1.0) % (forced expiratory volume in one second divided by forced expiratory volume), by 7 indexes with R = 0.921. Pulmonary function data regarding lung volumes and lung mechanics were estimated more accurately with greater R's than those for lung diffusion, but even in the latter the prediction was still statistically significant at p less than 0.01. We believe the multiple regression functions thus obtained are useful for estimating not only the overall but also the regional function of the lungs. (author)

  3. Comparison of aerosol inhalation lung images using BARC and other nebulizers

    International Nuclear Information System (INIS)

    Isawa, Toyoharu; Teshima, Takeo; Anazawa, Yoshiki; Miki, Makoto

    1994-01-01

    Various factors determine the site of inhaled aerosol deposition in the lungs. They are the size of aerosol the composition of carrier gas of the aerosol, the airflow rate, physico-chemical properties of the carrier gas or the aerosol, the shape and structure of the airways, and the body position during inhalation. Aerosol inhalation lung images were obtained in the same subjects using 99m Tc-human serum albumin aerosol generated by 3 different aerosol generators each producing different-sized aerosol and 2 or 3 days apart from each study. The size of aerosol produced by an ultrasonic nebulizer (Mistogen) was 1.93 Micron in activity median aerodynamic diameter (AMAD) with its geometric standard deviation (σg) of 1.73, that by a jet nebulizer (Ultra Vent) was 1.04 micron in AMAD with its σg of 1.71, and that by our BARC nebulizer, a type of a jet nebulizer, was 0.84 micron in AMAD with its σg of 1.73. In addition Technegas was also applied to selected patients. The latter produced aerosol of less than 0.2 micron in size at the largest and the majority, say, 95% or more of the generated aerosol was less than 0.1 micron in size by electron Microscopy. Each subject inhaled aerosol in resting tidal breathing through a mouth-piece with a one way double J valve with the nose clipped in the sitting position. After inhaling approximately 2-3 mCi (74 to 111 MBq) in the thorax, four view lung images were taken: anterior, posterior, and right and left laterals. 300 K counts per view were collected. They were not only pictured on polaroid films as analogue data but also recorded and stored in a computer as digital data. In case of Technegas breathing it for the RV (residual volume) to the TLC (total lung capacity) level followed by breath-holding for 5 to 10 sec in duration was repeated 2 to 3 times as a breathing maneuver instead of tidal breathing. Otherwise deposition efficiency of Technegas is very little because of the small size of the Technegas. Representative 10

  4. Characteristic pathological changes of main organs of rates after inhalation of depleted uranium aerosol

    International Nuclear Information System (INIS)

    Cao Zhenshan; Zhu Maoxiang; Yang Zhihua; Pan Xiujie; Li Yuanmin

    2005-01-01

    Objective: To explore the pathological and morphometric alteration of main organs of rat after inhalation of depleted uranium (DU) aerosole in order to provide information for medical protection against DU weapons. Methods: Routine pathological technique and morphometric measurements were used to observe histopathological and morphological changes in lung, kidney, spleen, liver, brain of rats 1-14 months after inhalation of DU aerosol. Results: After inhalation of DU aerosol, lymphocytic infiltration in the pulmonary parenchyma, serious bronchitis, pulmonary hemorrhage and abscess formation were seen in some of the rats; distinct dilatation of tubules in renal cortex and papillae, casts in some tubules of the cortex, medulla and papillae, and interstitial hemorrhage were found in some other rats; diminution of the area of splenic white pulp, reduction of megakaryocytic mitosis were also observed, the incidence and severity of above changes in the lung and kidney, but not in the liver and brain, showed dependance on the length of time after inhalation or the dose of DU inhaled. Conclusion There are evident injurious effects on rat lung, kidney and spleen by inhalation of DU aerosol. (authors)

  5. Experimental study of the effect of wearing dust-proof mask on inhaled aerosol particle size

    International Nuclear Information System (INIS)

    Lu Shunguang; Mei Chongsheng; Wu Yuangqing; Ren Liuan.

    1985-01-01

    This paper describes a method for measuring particle size of inhaled aerosol with a phantom of human head wearing dust-proof mask and a cascade impactor. The results showed that AMAD of inhaled aerosol was degraded and the size distribution of particles changed when the dust-proof mask was wearing. The leak rate of mask increased as the size of dust particles decreased. The results are applicable to estimate internal exposure dose and to evaluate the dust-proof capacity of mask

  6. A new mask to prevent environmental contamination during radio aerosol mouth-piece inhalation procedures

    International Nuclear Information System (INIS)

    Braga, Francisco Jose Hossri Nogueira.

    1994-01-01

    Environmental contamination is frequent during labelled aerosol mouth-piece inhalation procedures. Previous personnel data showed that in 18/18 situations air background activity has increased after inhalation and this may create serious routine and economical problems. We have tested a new adherent mask made of 3 M's TEGADERM in sixty 99 m Tc-DTPA inhalation studies and the results indicates that the use of such a mask may eliminate the problem of environmental contamination. The device is useful but not entirely efficient in cases when good skin adherence cannot be obtained. 48 refs, 10 figs, 2 tabs

  7. Quantification of inhaled aerosol particles composed of toxic household disinfectant using radioanalytical method.

    Science.gov (United States)

    Shim, Ha Eun; Lee, Jae Young; Lee, Chang Heon; Mushtaq, Sajid; Song, Ha Yeon; Song, Lee; Choi, Seong-Jin; Lee, Kyuhong; Jeon, Jongho

    2018-05-25

    To assess the risk posed by a toxic chemical to human health, it is essential to quantify its uptake in a living subject. This study aims to investigate the biological distribution of inhaled polyhexamethylene guanidine (PHMG) aerosol particle, which is known to cause severe pulmonary damage. By labeling with indium-111 ( 111 In), we quantified the uptake of PHMG for up to 7 days after inhalation exposure in rats. The data demonstrate that PHMG is only slowly cleared, with approximately 74% of inhaled particles persisting in the lungs after 168 h. Approximately 5.3% of inhaled particles were also translocated to the liver after 168 h, although the level of redistribution to other tissues, including the kidneys and spleen, was minimal. These observations suggest that large uptake and slow clearance may underlie the fatal inhalation toxicity of PHMG in humans. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Investigation of a Particle into Liquid Sampler to Study the Formation & Ageing of Secondary Organic Aerosol

    Science.gov (United States)

    Pereira, K. L.; Hamilton, J. F.; Rickard, A. R.; Bloss, W. J.; Alam, M. S.; Camredon, M.; Munoz, A.; Vazquez, M.; Rodenas, M.; Vera, T.; Borrás, E.

    2012-12-01

    The atmospheric oxidation of Volatile Organic Compounds (VOCs) in the presence of NOx results in the formation of tropospheric ozone and Secondary Organic Aerosol (SOA) [Hallquist et al., 2009]. Whilst SOA is known to affect both climate and human health, the VOC oxidation pathways leading to SOA formation are poorly understood [Solomon et al., 2007]. This is in part due to the vast number and the low concentration of SOA species present in the ambient atmosphere. It has been estimated as many as 10,000 to 100,000 VOCs have been detected in the atmosphere, all of which can undergo photo-chemical oxidation and contribute to SOA formation [Goldstein and Galbally, 2007]. Atmospheric simulation chambers such as the EUropean PHOtoREactor (EUPHORE) in Valencia, Spain, are often used to study SOA formation from a single VOC precursor under controlled conditions. SOA composition and formation can be studied using online techniques such as Aerosol Mass Spectrometry (AMS), which provide high time resolution but limited structural information [Zhang et al., 2007]. Offline techniques, such as collection onto filters, extraction and subsequent analysis, provide detailed SOA composition but only usually one or two samples per experiment. In this work we report time resolved SOA composition analysis using a Particle into Liquid Sampler (PILS) followed by Liquid Chromatography Ion-Trap Mass Spectrometry (LC-IT-MS/MS) and Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FTICR-MS/MS). Experiments were performed at EUPHORE investigating the formation and composition of Methyl Chavicol SOA. Methyl Chavicol (also known as Estragole) was identified as the highest floral emission from an oil palm plantation in Malaysian Borneo and has also been observed in US pine forests [Bouvier-Brown et al., 2009; Misztal et al., 2010]. Previous studies indicate a high SOA yield from Methyl Chavicol at around 40 % [Lee et al., 2006], however currently there have been very few literature

  9. Creation of device for monitoring of inhalation exposure doses in 'Ukryttia' object conditions considering submicron aerosols

    International Nuclear Information System (INIS)

    Melenevskij, A.Eh.; Kravchuk, T.A.; Ushakov, I.A.

    2003-01-01

    In the conditions of air enriched with Short-Lived Aerosols (SLA), the examinations of created device ASMA sampler were conducted in order to define its ability of educing rougher fractions from aspirated aerosol compositions. It is shown that in airflow velocity intervals from 100 to 140 m/s aerodynamic diameter of an effluent fraction varies from 0.9 to 0.7 microns. The algorithm of measurement result processing of aspirated filter strata activity is described.Using the numerical modeling, the efficiency of offered procedure of relative measurements is demonstrated

  10. An In Vitro Aerosolization Efficiency Comparison of Generic and Branded Salbutamol Metered Dose Inhalers

    Directory of Open Access Journals (Sweden)

    Sara Rahimkhani, Saeed Ghanbarzadeh, Ali Nokhodchi, Hamed Hamishehkar

    2017-03-01

    Full Text Available Background: Due to the high rate of pulmonary diseases, respiratory drug delivery systems have been attracted excessive attention for the past decades. Because of limitations and growing drug bill, physicians are encouraged to prescribe generically whenever possible. The purpose of this study was to evaluate whether there was any significant difference in aerosolization performance between a reference brand Salbutamol (A Metered Dose Inhalers (MDIs and two generic products (B and C. Methods: The aerosolization performance of MDIs was evaluated by calculating aerosolization indexes including fine particle fraction (FPF, fine particle dose (FPD, geometric standard deviation (GSD and mass median aerodynamic diameters (MMAD by using the next generation impactor. Results: Although aerosolization indexes of MDI A were superior than the Iranian brands, but the differences were not statistically significant. Conclusion: These results verified that generic MDIs deliver similar quantities of Salbutamol to the reference brand and aerosolization performance parameters of generic Salbutamol MDIs did not differ significantly from the reference brand.

  11. The effect of varying physical and chemical characteristics of inhaled plutonium aerosols on metabolism and excretion

    International Nuclear Information System (INIS)

    Mewhinney, J.A.; Muggenburg, B.A.; McClellan, R.O.; Miglio, J.J.

    1976-01-01

    The effects of different chemical and physical parameters of plutonium aerosols on lung retention, tissue distribution and excretion patterns were evaluated in beagle dogs. Polydisperse aerosols of 239 Pu of different chemical form were produced by heating droplets nebulized from a solution of 239 PuIV in 1M HC1 to temperatures ranging from 325 0 C to 1150 0 C. Droplets containing 238 Pu(OH) 4 were treated at 1150 0 C and the resultant polydisperse aerosol used or separated into monodisperse size groups. Beagle dogs were exposed by inhalation to provide initial lung burdens in the range of 0.75 to 1.0μCi. The aerosols were characterized as to particle size and size distribution, and an in-vitro solubility measurement was made on samples of the aerosol from each animal exposure. Different production temperatures for the 239 Pu aerosols resulted in lung retention half-times that increased as the production temperature increased. The 239 Pu tissue distribution and urinary excretion patterns were correlated with lung retention. Faecal excretion was greater for aerosols produced at lower temperatures. Lung retention half-times for 238 Pu monodisperse aerosols were not greatly different from particle sizes of 0.8 and 1.9μm activity median aerodynamic diameter (AMAD). The third monodisperse aerosol intended to be 3.0μm AMAD had a bimodal particle size distribution and contained a significant fraction of readily soluble material. The 238 Pu polydisperse aerosol had a slightly lower lung retention, increased urinary excretion and translocation to tissues than the comparable 239 Pu polydisperse material. This study serves to emphasize the importance of complete analysis of the aerosol material as well as early excretion data following accidental human exposure to aerosols containing plutonium. The role of chemical form and aerosol particle size in evaluation of such cases is discussed. (author)

  12. Inhalation deposition and retention patterns of a U-Pu chain aggregate aerosol

    International Nuclear Information System (INIS)

    Briant, J.K.; Sanders, C.L.

    1987-01-01

    Chain aggregate aerosol particles are normally formed during many high-temperature combustion and vaporization processes. The shape of chain aggregate aerosol particles could have an effect on the pattern of inhalation deposition and retention of the particles in the respiratory tract. A chain aggregate aerosol of nuclear reactor fuel could be present as an inhalation hazard if it were released to the atmosphere after a meltdown, core-disruptive accident. Rats were exposed to a chain aggregate U-Pu aerosol made by laser vaporization of mixed-oxide, breeder reactor fuel (20% plutonium dioxide and 80% uranium dioxide), then sacrificed to measure the clearance and retention of the fuel aerosol particles. Deposition of the 0.7-micron (activity median aerodynamic equivalent diameter) aerosol particles resulted in an average initial lung burden of 4140 Bq alpha activity. The chain aggregate particle shape was not a major factor in the total deposition; however, it may have influenced the regional distribution of the activity deposited. Retention of the particles in the upper airways of the tracheobronchial tree was on the order of 1% of the concurrent lung burden, which is consistent with recent data of other investigations. This study indicates that insoluble chain aggregate particles are retained in the tracheobronchial airways to a degree similar to simple spherically shaped particles of equivalent volume diameter

  13. Flavourings significantly affect inhalation toxicity of aerosol generated from electronic nicotine delivery systems (ENDS).

    Science.gov (United States)

    Leigh, Noel J; Lawton, Ralph I; Hershberger, Pamela A; Goniewicz, Maciej L

    2016-11-01

    E-cigarettes or electronic nicotine delivery systems (ENDS) are designed to deliver nicotine-containing aerosol via inhalation. Little is known about the health effects of flavoured ENDS aerosol when inhaled. Aerosol from ENDS was generated using a smoking machine. Various types of ENDS devices or a tank system prefilled with liquids of different flavours, nicotine carrier, variable nicotine concentrations and with modified battery output voltage were tested. A convenience sample of commercial fluids with flavour names of tobacco, piña colada, menthol, coffee and strawberry were used. Flavouring chemicals were identified using gas chromatography/mass spectrometry. H292 human bronchial epithelial cells were directly exposed to 55 puffs of freshly generated ENDS aerosol, tobacco smoke or air (controls) using an air-liquid interface system and the Health Canada intense smoking protocol. The following in vitro toxicological effects were assessed: (1) cell viability, (2) metabolic activity and (3) release of inflammatory mediators (cytokines). Exposure to ENDS aerosol resulted in decreased metabolic activity and cell viability and increased release of interleukin (IL)-1β, IL-6, IL-10, CXCL1, CXCL2 and CXCL10 compared to air controls. Cell viability and metabolic activity were more adversely affected by conventional cigarettes than most tested ENDS products. Product type, battery output voltage and flavours significantly affected toxicity of ENDS aerosol, with a strawberry-flavoured product being the most cytotoxic. Our data suggest that characteristics of ENDS products, including flavours, may induce inhalation toxicity. Therefore, ENDS users should use the products with caution until more comprehensive studies are performed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  14. Influence of elastase-induced emphysema and the inhalation of an irritant aerosol on deposition and retention of an inhaled insoluble aerosol in Fischer-344 rats

    International Nuclear Information System (INIS)

    Damon, E.G.; Mokler, B.V.; Jones, R.K.

    1983-01-01

    The purpose of this study was to assess the effects of elastase-induced pulmonary emphysema and the inhalation of an irritant aerosol (Triton X-100, a nonionic surfactant similar to those used in a number of pressurized consumer products) on pulmonary deposition and retention of an insoluble test aerosol, 59 FE-labeled Fe 2 O 3 . Untreated rats or rats pretreated by intratracheal in stillation with elastase were exposed to an aerosol of 59 Fe-labeled Fe 2 O 3 either 18 hr or 7 days after exposure to aerosslized Triton X-100 which was administered in doses of 20, 100, or 200 μg/g of lung. Rats pretreated with elastase had significantly lower pulmonary deposition of 59 Fe than the untreated controls (p 2 O 3 was unaffected by pretreatment with Triton X-100. Elastase treatment alone had no effect on retention of Fe 2 O 3 . Triton X-100 administered 18 hr prior to exposure of rats to Fe 2 O 3 aerosol resulted in dose-related increases in whole-body retention of 59 Fe. When rats were exposed to Triton X-100 7 days before exposure to Fe 2 O 3 , increased retention of 59 Fe was noted only in those treated at the highest Triton X-100 dose level (200 μg/g). 20 references, 5 tables

  15. Device for contaminating laboratory animals by inhalation of radioactive aerosols

    International Nuclear Information System (INIS)

    Lutz, M.; Rouvroy, H.

    1966-01-01

    The contamination enclosure is made up of a sphere to which are attached an aerosol generator, containers adapted to the animals to be used, and the atmospheric sampling system. The sphere is placed in a protective glove-box, the latter being itself protected by an introduction chamber fitted with locking access lids. A detailed description is given of the working principle. As an example, some results are given concerning the contamination of rats by a plutonium oxide aerosol: characteristics of the powder (mean diameter 0.50 μ - standard deviation: 1.4), examination and evolution of the atmospheric activity as a function of time, evaluation of the retention by the lungs by means of histological and autoradiographic examinations. (authors) [fr

  16. Long-term clearance of accidentally inhaled 60Co aerosols in humans

    International Nuclear Information System (INIS)

    Beleznay, E.; Osvay, M.

    1993-03-01

    Long-term body retention was measured on six workers inhaling 60 Co aerosols incidentally during manipulation with a high activity 60 Co source. An improved whole body counter technique and calibration provided good conditions to follow the body clearance over 4 years. A two-detector profile scanning arrangement was used to measure the activity distribution 'in vivo' over the lung region. The observed whole body retention followed a two-exponential time function between 10-1500 days. The consistency of the measured retention pattern with ICRP inhalation model was investigated assuming different aerosol size distributions. A possible extension of ICRP lung model is proposed to take into account the actual pulmonary lung clearance determined individually. (R.P.) 29 refs.; 15 figs.; 6 tabs

  17. Comparison of modeled estimates of inhalation exposure to aerosols during use of consumer spray products.

    Science.gov (United States)

    Park, Jihoon; Yoon, Chungsik; Lee, Kiyoung

    2018-05-30

    In the field of exposure science, various exposure assessment models have been developed to complement experimental measurements; however, few studies have been published on their validity. This study compares the estimated inhaled aerosol doses of several inhalation exposure models to experimental measurements of aerosols released from consumer spray products, and then compares deposited doses within different parts of the human respiratory tract according to deposition models. Exposure models, including the European Center for Ecotoxicology of Chemicals Targeted Risk Assessment (ECETOC TRA), the Consumer Exposure Model (CEM), SprayExpo, ConsExpo Web and ConsExpo Nano, were used to estimate the inhaled dose under various exposure scenarios, and modeled and experimental estimates were compared. The deposited dose in different respiratory regions was estimated using the International Commission on Radiological Protection model and multiple-path particle dosimetry models under the assumption of polydispersed particles. The modeled estimates of the inhaled doses were accurate in the short term, i.e., within 10 min of the initial spraying, with a differences from experimental estimates ranging from 0 to 73% among the models. However, the estimates for long-term exposure, i.e., exposure times of several hours, deviated significantly from the experimental estimates in the absence of ventilation. The differences between the experimental and modeled estimates of particle number and surface area were constant over time under ventilated conditions. ConsExpo Nano, as a nano-scale model, showed stable estimates of short-term exposure, with a difference from the experimental estimates of less than 60% for all metrics. The deposited particle estimates were similar among the deposition models, particularly in the nanoparticle range for the head airway and alveolar regions. In conclusion, the results showed that the inhalation exposure models tested in this study are suitable

  18. Microprocessor-controlled inhalation system for repeated exposure of animals to aerosols

    International Nuclear Information System (INIS)

    Carpenter, R.L.; Barr, F.P.; Leydig, R.L.; Rajala, R.E.

    1979-01-01

    A microprocessor-controlled inhalation exposure system (MCIES) has been built to automate aerosol generation and sampling while controlling exposure time for animal toxicity studies. The system has a time resolution of 0.1 s and automatically sequences the exposure events from initiation to temination of the exposure. The operator is required to preset all airflows, read in a paper tape containing the time sequence of events, and initiate the automatic sequence by closing a switch

  19. Inhalation toxicology of industrial plutonium and uranium oxide aerosols II. Deposition, retention and dosimetry

    International Nuclear Information System (INIS)

    Stanley, J.A.; Eidson, A.F.; Mewhinney, J.A.; Mo, T.

    1978-01-01

    A series of studies has been initiated in which powdered fuel materials obtained at industrial sites have been aerosolized in the dry state for the inhalation exposure of Fischer-344 rats, Beagle dogs and Cynomolgus monkeys to evaluate the potential biological hazard of such accidents. The materials chosen for study were 750 deg. C heat-treated mixed PuO 2 and UO 2 obtained from a ball milling process and 1750 deg. C heat-treated (U,Pu)O 1.97 powder obtained from the centerless grinding of fuel pellets. Care was taken to insure that the regenerated aerosols used in animal inhalation exposures had similar particle size and size distribution characteristics to those measured during glove box sampling at the industrial plant. The deposition, retention, distribution and excretion of these materials are being studied, using serial sacrifice of animals at times from 4 hours to several years after inhalation exposure. Periodic excreta samples are collected on all animals. Biological samples are analyzed to yield data on Pu, Am and U content. Data from animals sacrificed up to one year will be presented. The retention of 239 Pu and 241 Am in the lung and their subsequent clearance and translocation to other tissues such as liver, skeleton and tracheobronchial lymph nodes will be discussed in relation to the influence of species and of the physical chemical properties of the exposure aerosol. (author)

  20. Efficient Nose-to-Lung (N2L) Aerosol Delivery with a Dry Powder Inhaler.

    Science.gov (United States)

    Longest, P Worth; Golshahi, Laleh; Behara, Srinivas R B; Tian, Geng; Farkas, Dale R; Hindle, Michael

    2015-06-01

    Delivering aerosols to the lungs through the nasal route has a number of advantages, but its use has been limited by high depositional loss in the extrathoracic airways. The objective of this study was to evaluate the nose-to-lung (N2L) delivery of excipient enhanced growth (EEG) formulation aerosols generated with a new inline dry powder inhaler (DPI). The device was also adapted to enable aerosol delivery to a patient simultaneously receiving respiratory support from high flow nasal cannula (HFNC) therapy. The inhaler delivered the antibiotic ciprofloxacin, which was formulated as submicrometer combination particles containing a hygroscopic excipient prepared by spray-drying. Nose-to-lung delivery was assessed using in vitro and computational fluid dynamics (CFD) methods in an airway model that continued through the upper tracheobronchial region. The best performing device contained a 2.3 mm flow control orifice and a 3D rod array with a 3-4-3 rod pattern. Based on in vitro experiments, the emitted dose from the streamlined nasal cannula had a fine particle fraction <5 μm of 95.9% and mass median aerodynamic diameter of 1.4 μm, which was considered ideal for nose-to-lung EEG delivery. With the 2.3-343 device, condensational growth in the airways increased the aerosol size to 2.5-2.7 μm and extrathoracic deposition was <10%. CFD results closely matched the in vitro experiments and predicted that nasal deposition was <2%. The developed DPI produced high efficiency aerosolization with significant size increase of the aerosol within the airways that can be used to enable nose-to-lung delivery and aerosol administration during HFNC therapy.

  1. Evaluation of sampling inhalable PM10 particulate matter (≤ 10 μm) using co-located high volume samplers

    International Nuclear Information System (INIS)

    Rajoy, R R S; Dias, J W C; Rego, E C P; Netto, A D Pereira

    2015-01-01

    This paper presents the results of the determination of the concentrations of atmospheric particulate matter ≤ 10 μm (PM10), collected simultaneously by six PM10 high volume samplers from two different manufacturers installed in the same location. Fifteen samples of 24 h were obtained with each equipment at a selected urban area of Rio de Janeiro city. The concentration of PM10 ranged between 10.73 and 54.04 μg m −3 . The samplers were considered comparable to each other, as the adopted methodology presented good repeatability

  2. Lung Deposition Analyses of Inhaled Toxic Aerosols in Conventional and Less Harmful Cigarette Smoke: A Review

    Directory of Open Access Journals (Sweden)

    Yu Feng

    2013-09-01

    Full Text Available Inhaled toxic aerosols of conventional cigarette smoke may impact not only the health of smokers, but also those exposed to second-stream smoke, especially children. Thus, less harmful cigarettes (LHCs, also called potential reduced exposure products (PREPs, or modified risk tobacco products (MRTP have been designed by tobacco manufacturers to focus on the reduction of the concentration of carcinogenic components and toxicants in tobacco. However, some studies have pointed out that the new cigarette products may be actually more harmful than the conventional ones due to variations in puffing or post-puffing behavior, different physical and chemical characteristics of inhaled toxic aerosols, and longer exposure conditions. In order to understand the toxicological impact of tobacco smoke, it is essential for scientists, engineers and manufacturers to develop experiments, clinical investigations, and predictive numerical models for tracking the intake and deposition of toxicants of both LHCs and conventional cigarettes. Furthermore, to link inhaled toxicants to lung and other diseases, it is necessary to determine the physical mechanisms and parameters that have significant impacts on droplet/vapor transport and deposition. Complex mechanisms include droplet coagulation, hygroscopic growth, condensation and evaporation, vapor formation and changes in composition. Of interest are also different puffing behavior, smoke inlet conditions, subject geometries, and mass transfer of deposited material into systemic regions. This review article is intended to serve as an overview of contributions mainly published between 2009 and 2013, focusing on the potential health risks of toxicants in cigarette smoke, progress made in different approaches of impact analyses for inhaled toxic aerosols, as well as challenges and future directions.

  3. Monitoring the Inhalation Flow Rate of Nebulized Aerosols Using an Ultrasonic Flow Meter: In Vitro Assessment.

    Science.gov (United States)

    Yang, Michael Y; Chan, Hak-Kim

    2017-06-01

    The measurement of aerosol flow rates without obscuration of the flow is of particular concern with in vivo lung deposition studies, where precise knowledge of aerosol particle size distributions is a necessary requirement for the development of predictive correlations. This study examines the utility of an ultrasonic flow meter for such measurements and determines if a valved system can be attached to the flow meter for sampling exhaled aerosols. The flow rate across a D-30 flow meter was compared with and without nebulization of 0.9% saline aerosols from a PARI LC Sprint nebulizer. Particle size distributions of the nebulized aerosol before and after adding the D-30 flow meter and duckbill valve were measured using a Spraytec laser diffraction system. Finally, the ability of the Thor D-30 to capture a realistic breathing profile was assessed. The mean ± standard error flow rates measured by the D-30 flow meter with and without nebulization were 10.4 ± 0.1 versus 10.4 ± 0.1 L/min, 66.4 ± 0.1 versus 67.2 ± 0.1 L/min, and 89.9 ± 0.1 versus 91.4 ± 0.1 L/min. The D-30 flow meter did not considerably affect the volumetric median diameter (VMD) of the aerosols, while the VMD reduced slightly by 0.65 μm at 10 L/min and 0.69 μm at 72 L/min upon the inclusion of a duckbill valve. Time-weighted average inhalation flow rates measured by D-30 flow meters placed upstream and downstream of the one-way valve agreed well, 31.9 versus 32.6 L/min, respectively. The D-30 flow meter can be used to accurately measure inhalation flow rates of nebulized aerosols without significantly impacting particle size distributions, and one-way duckbill valves can be used to isolate the inhalation portion of a breathing pattern to facilitate collection of exhaled doses.

  4. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Science.gov (United States)

    2010-07-01

    ... through which sample air is flowing during performance of this test. (3) A no-flow filter is a sample filter through which no sample air is intended to flow during performance of this test. (4) A channel is... a device or means to allow or cause the aerosol to be routed to one of several channels. (c...

  5. Granulometric determinations and inhalation dose assessment for atmospheric aerosol contaminated by 137Cs

    International Nuclear Information System (INIS)

    Castellani, C.M.; Luciani, A.; Oliviero, L.; Donato, R.

    1996-07-01

    During the redevelopment of Brescia freight-yard a measurement campaign of atmospheric aerosol was carried out: in fact a 137 Cs ground contamination, caused by the permanence of wagons carrying iron materials contaminated by this radionuclide, had been found out. During the redevelopment phases of excavation and can filling the workers were exposed to the danger of radioactive aerosol inhalation. The aim of the measurement campaign was to test the aerosol sampling and granulometric analysis methodologies with their sensitivity related to the inhalation dose assessments. The results of both aerosuspended mass and activity, evaluated by means of a portable cascade impactor, are presented. The granulometries have been interpolated with a log normal distribution using an iterative routine minimizing the square deviation between the calculated and experimental data. The results related to the dose assessments are also presented. These evaluations have been carried out using both the granulometric information obtained and the more recent models (ICRP 66) both the total concentration data and the dose coefficients referring to the standard conditions of ICRP 68 and of the Italian law (D.Lgs. 230/95). Furthermore the significance and the reliability of the dose assessments referring to the different methodologies are discussed, also in relation to the possibility of using this sampling methodologies for other radionuclides and different exposure conditions

  6. The deposition - a modern phenomenon in the evaluation of inhalation risk of mining aerosols

    Directory of Open Access Journals (Sweden)

    Ľubomír Legáth

    2007-04-01

    Full Text Available The deposition is defined as an array of processes causing a part of the inhaled aerosol to remain (after its expiration in the respiratory tract. The particles retained in the respiratory tract are called deposits. The deposition encompasses of three different mechanisms: impaction, sedimentation and Brown molecular movement combined with the diffusion. The impaction remains the most potential contribution to the deposition in the conductive zone of the respiratory tract. While the sedimentation and diffusion in conjunction with the Brown molecular movement have a major impact in the respiratory area with the zero flow movement. The above listed mechanisms participate with the different ratio to the deposition at respective parts of the respiratory tract.The deposition depends on physical and chemical properties of inhaled aerosols as well as on the susceptibility of each individual. The size, shape, mass, and electric charges are among the basic characteristics of aerosols. The individual susceptibility is mainly influenced by an anatomical arrangement of respiratory tract, tidal volume, frequency of breathing, and breath holding.

  7. Quantitative analysis and design of a spray aerosol inhaler. Part 2: improvements in mouthpiece performance.

    Science.gov (United States)

    Hindle, Michael; Longest, P Worth

    2013-10-01

    The objective of this study was to utilize previously identified critical design attributes for the capillary aerosol generator as a model spray inhaler in order to develop a second-generation device that minimized aerosol drug deposition in the mouthpiece. Computational fluid dynamics (CFD) predictive analysis of the critical design attributes indicated that turbulence intensity should be reduced and the effective mouthpiece diameter should be increased. Two second-generation inhaler mouthpieces meeting these specifications were manufactured and tested. The first device (Design 1) implemented a larger cross-sectional area in the mouthpiece and streamlined flow, whereas the second device (Design 2) used a perforated mouthpiece wall. An in vitro deposition study was performed to quantify the deposition of drug mass in the mouthpieces and connected induction ports, and the results were compared with the CFD predictions. The two second-generation mouthpieces reduced in vitro aerosol deposition from the original value of 7.8% to values of 2.1% (Device 1) and 4.3% (Device 2), without largely altering the induction port deposition. This was achieved by design alterations aimed at reducing turbulence intensity and increasing the effective mouthpiece diameter. CFD model predictions were in good agreement with the in vitro experimental data. A second-generation spray inhaler mouthpiece with low drug deposition was developed using a predictive CFD model and in vitro experiments. Applying this quantitative analysis and design methodology to medical devices, which is similar to the Quality by Design paradigm, could provide significant advantages compared with traditional approaches.

  8. Repeated inhalation exposure of Beagle dogs to aerosols of 239PuO2. XII

    International Nuclear Information System (INIS)

    Diel, J.H.; Hahn, F.F.; Muggenburg, B.A.

    1988-01-01

    Beagle dogs were exposed once or semi-annually for 10 yr by inhalation to aerosols of 239 PuO 2 to study the relative doses and effects of these two types of exposures. All exposures have been completed. Dogs exposed at high levels died predominantly of radiation pneumonitis and pulmonary fibrosis. Dogs exposed at lower levels, either once or repeatedly, are dying of a variety of causes including lung cancer. Dogs have survived up to 11 yr after their first exposure. Preliminary results suggest that single and repeated exposures cause similar health effects for equal accumulated radiation doses. (author)

  9. Experimental study of contamination by inhalation of radioactive iodine aerosols. Biological balance; Etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif bilan biologique

    Energy Technology Data Exchange (ETDEWEB)

    Marble, G. [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    Several articles have been published concerning research into contamination produced by inhalation of radioactive iodine aerosols in monkeys. Results dealing with the biological balance of this contamination are presented and discussed in this report. (author) [French] L'etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif effectuee chez le singe a fait l'objet de plusieurs publications. Les resultats concernant le bilan biologique de cette contamination sont presentes et discutes dans ce rapport. (auteur)

  10. The suitability of the IOM foam sampler for bioaerosol sampling in Occupational Environments.

    Science.gov (United States)

    Haatainen, Susanna; Laitinen, Juha; Linnainmaa, Markku; Reponen, Tiina; Kalliokoski, Pentti

    2010-01-01

    Concurrent samples were collected with Andersen and IOM foam samplers to determine whether if the IOM foam sampler can be applied to collect culturable microorganisms. Two different kinds of aerosols were studied: peat dust in a power plant and mist from coolant fluid aerosolized during grinding of blades and rollers in a paper mill. In the power plant, the concentrations of fungi were 2-3 times higher in the IOM samples than in the Andersen samples. However, more fungal genera were identified in the latter case. The methods yielded similar concentrations of bacteria and actinobacteria in the power plant. On the other hand, the performance of the IOM foam sampler was very poor in the paper mill, where stress-sensitive gram-negative bacteria dominated; low concentration of bacteria was detected in only one IOM sample even though the concentration of bacteria often exceeded even the upper detection limit in the Andersen impactor samples. It could be concluded that the IOM foam sampler performs quite well for collecting inhalable fungi and actinobacteria. However, the Andersen sampler provides better information on fungal genera and concentrations of gram-negative bacteria. Personal sampling with the IOM foam sampler provided an important benefit in the power plant, where the concentration ratio of personal to stationary samples was much higher for bacteria than for inhalable or respirable dust.

  11. Design, characterization, and aerosolization of organic solution advanced spray-dried moxifloxacin and ofloxacin dipalmitoylphosphatidylcholine (DPPC) microparticulate/nanoparticulate powders for pulmonary inhalation aerosol delivery

    Science.gov (United States)

    Duan, Jinghua; Vogt, Frederick G; Li, Xiaojian; Hayes, Don; Mansour, Heidi M

    2013-01-01

    The aim of this study was to design and develop respirable antibiotics moxifloxacin (MOXI) hydrochloride and ofloxacin (OFLX) microparticles and nanoparticles, and multifunctional antibiotics particles with or without lung surfactant 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) for targeted dry powder inhalation delivery as a pulmonary nanomedicine. Particles were rationally designed and produced by advanced spray-drying particle engineering from an organic solution in closed mode (no water) from dilute solution. Scanning electron microscopy indicated that these particles had both optimal particle morphology and surface morphology, and the particle size distributions were suitable for pulmonary delivery. Comprehensive and systematic physicochemical characterization and in vitro aerosol dispersion performance revealed significant differences between these two fluoroquinolone antibiotics following spray drying as drug aerosols and as cospray-dried antibiotic drug: DPPC aerosols. Fourier transform infrared spectroscopy and confocal Raman microspectroscopy were employed to probe composition and interactions in the solid state. Spray-dried MOXI was rendered noncrystalline (amorphous) following organic solution advanced spray drying. This was in contrast to spray-dried OFLX, which retained partial crystallinity, as did OFLX:DPPC powders at certain compositions. Aerosol dispersion performance was conducted using inertial impaction with a dry powder inhaler device approved for human use. The present study demonstrates that the use of DPPC offers improved aerosol delivery of MOXI as cospray-dried microparticulate/nanoparticulate powders, whereas residual partial crystallinity influenced aerosol dispersion of OFLX and most of the compositions of OFLX:DPPC inhalation powders. PMID:24092972

  12. Dosimetry of 239Pu in dogs that inhaled monodisperse aerosols of 239PuO2

    International Nuclear Information System (INIS)

    Guilmette, R.A.; Muggenburg, B.A.; Hahn, F.F.; Mewhinney, J.A.; Seiler, F.A.; Boecker, B.B.; McClellan, R.O.

    1987-01-01

    Existing data from human exposure cases and experimental animal studies on the fate and dosimetry of inhaled insoluble Pu particles are inadequate to provide a comprehensive description and evaluation of the tissues at risk from the alpha radiations of Pu. To improve our knowledge of the dosimetry of inhaled insoluble 239 PuO 2 , this paper describes the uptake and retention of 239 Pu in the tissues of dogs that received single inhalation exposures to monodisperse aerosols of 239 PuO 2 . These data include times through 3 years after exposure. Using analytical functions fitted to each tissue data set, 1100-day radiation doses were calculated for lung, liver, skeleton, kidney, spleen, and tracheobronchial, mediastinal, sternal, hepatic, mandibular, and retropharyngeal lymph nodes. The dosimetry results suggest that the lung and lymph nodes associated with lymphatic drainage of the respiratory tract are the principal sites of alpha irradiation. However, the doses for the different respiratory tract lymph nodes vary by a factor of 2000, suggesting that assuming equivalent doses to respiratory tract lymph nodes is not appropriate. Other tissues receive radiation doses also but at levels one to three orders of magnitude less than the lung. Particle size dependence on uptake and retention was noted for the skeleton, mediastinal lymph nodes, hepatic lymph nodes, retropharyngeal lymph nodes, and mandibular lymph nodes

  13. Inhalants

    Science.gov (United States)

    ... Alcohol Club Drugs Cocaine Fentanyl Hallucinogens Inhalants Heroin Marijuana MDMA (Ecstasy/Molly) Methamphetamine Opioids Over-the-Counter Medicines Prescription Medicines Steroids (Anabolic) Synthetic Cannabinoids (K2/Spice) Synthetic Cathinones (Bath Salts) Tobacco/ ...

  14. Novel devices for individualized controlled inhalation can optimize aerosol therapy in efficacy, patient care and power of clinical trials

    Directory of Open Access Journals (Sweden)

    Fischer A

    2009-12-01

    Full Text Available Abstract In the treatment of pulmonary diseases the inhalation of aerosols plays a key role - it is the preferred route of drug delivery in asthma, chronic obstructive pulmonary disease (COPD and cystic fibrosis. But, in contrast to oral and intravenous administration drug delivery to the lungs is controlled by additional parameters. Beside its pharmacology the active agent is furthermore determined by its aerosol characteristics as particle diameter, particle density, hygroscopicity and electrical charge. The patient related factors like age and stage of pulmonary disease will be additionally affected by the individual breathing pattern and morphometry of the lower airways. A number of these parameters with essential impact on the pulmonary drug deposition can be influenced by the performance of the inhalation system. Therefore, the optimization of nebulisation technology was a major part of aerosol science in the last decade. At this time the control of inspiration volume and air flow as well as the administration of a defined aerosol bolus was in the main focus. Up to date a more efficient and a more targeted pulmonary drug deposition - e.g., in the alveoli - will be provided by novel devices which also allow shorter treatment times and a better reproducibility of the administered lung doses. By such means of precise dosing and drug targeting the efficacy of inhalation therapy can be upgraded, e.g., the continuous inhalation of budesonide in asthma. From a patients' perspective an optimized inhalation manoeuvre means less side effects, e.g., in cystic fibrosis therapy the reduced oropharyngeal tobramycin exposure causes fewer bronchial irritations. Respecting to shorter treatment times also, this result in an improved quality of life and compliance. For clinical trials the scaling down of dose variability in combination with enhanced pulmonary deposition reduces the number of patients to be included and the requirement of pharmaceutical

  15. Applications of aerosol inhalation cine-scintigraphy for, clinical investigations of mucociliary transport

    International Nuclear Information System (INIS)

    Ito, Shinsaku; Mikami, Riichiro; Ryujin, Yoshitada; Imai, Teruhiko; Ohnuki, Masahiro; Narita, Nobuhiro

    1984-01-01

    Mucociliary transport and cough effect were studied in 10 healthy controls and 116 patients with respiratory diseases using aerosol inhalation cine-scintigraphy which permits visualization of the movement of inhaled aerosols. Additionally, the effectiveness of β-adrenergic stimulant on mucociliary transport was evaluated in 8 normal cases by this method. 1. In healthy controls, the aerosol-bolus moved to the cephalad side rapidly and smoothly in the main bronchus and the trachea, but in many cases of respiratory diseases, we recognized various abnormal patterns such as slow movement, spiral movement, regurgitation etc. We consider that the bolus movements can be used as an index of the mucociliary transport. 2. We found low grade abnormality of bolus movement in cases of atopic bronchial asthma, pulmonary emphysema, silicosis, interstitial pneumonia and asbestosis, but high grade abnormality in cases of bronchiectasis, pulmonary emphysema with chronic bronchitis, mixed or infectious bronchial asthma, chronic bronchitis and especially acute pulmonary infection and diffuse panbronchiolitis. Normal patterns were observed in atopic asthma patients in remission, but abnormal patterns in cases of attack. With larger daily volumes of sputum, the bolus movements showed higher greater abnormality. 3. Bolus movements by coughing were seen most frequently in patients who had produced moderate volumes of sputum and in whom the bolus had stopped at the first carina. Bolus movements by coughing were classified into three groups: expectoration, cephalad movement that stopped halfway, and regurgitation. When the bolus was in the trachea, especially located on the oral side, we observed that expectoration by coughing was more effective. Patients with obstructive pulmonary diseases had lower effciency of expectoration by coughing. 4. We confirmed that terbutaline (β-adrenergic stimulant) accelerated the mucociliary transport. (author)

  16. Two-week aerosol inhalation study on polyethylene glycol (PEG) 3350 in F-344 rats.

    Science.gov (United States)

    Klonne, D R; Dodd, D E; Losco, P E; Troup, C M; Tyler, T R

    1989-03-01

    PEGs in the 3000 to 4000 MW range are used in many pharmaceutical and cosmetic applications; they produce little ocular or dermal irritation and have extremely low acute and subchronic toxicity by oral and dermal routes of administration. However, little information exists on the potential of aerosols of these materials to produce adverse health effects. F-344 rats were exposed to aerosols of PEG 3350 (20% w:w in water) at 0, 109, 567, or 1008 (highest attainable) mg/m3 for 6 hr/d, 5 d/wk for 2 wk. No exposure-related toxicity was found with regard to clinical signs, ophthalmology, serum chemistry, urinalysis, or gross pathology. Exposure-related effects included: a 50% increase in the neutrophil count (males only) at 1008 mg/m3; decreased body weight gain (16%) for both the 567 and 1008 mg/m3 groups (males only); absolute lung weights of both sexes were increased 10 and 18% for the 567 and 1008 mg/m3 groups, respectively. A slight increase in the number of macrophages in the alveoli was the only change observed histologically in all PEG 3350-exposed groups. Therefore, inhalation of aerosols of PEG 3350 at concentrations up to 1008 mg/m3 produced relatively little toxicity in rats, the lung was the target organ, and the no-observable-effect-level was between 109 to 567 mg/m3.

  17. Study on the deposition patterns of aerosol inhalation scintigraphy, 1; Comparison of the deposition patterns of aerosol inhalation scintigraphy with lung function tests in pulmonary diseases

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Hiroyuki [Nara Medical Univ., Kashihara (Japan)

    1989-06-01

    The deposition patterns of aerosol inhalation scintigraphies and lung function tests were studied in 102 cases; 64 cases of obstructive pulmonary diseases (19 pulmonary emphysema, 27 diffuse panbronchiolitis, 18 chronic bronchitis) and 38 restrictive pulmonary disease (15 idiopathic interstitial pneumonia, 16 pulmonary asbestosis, 7 interstitial pneumonia due to collagen vascular disease). The deposition patterns were classified into 5 patterns (Type A:normal homogenous distribution; Type B: mildly unhomogenous distribution; Type C: severely unhomogenous distribution mingled with hot spots; Type D: non-hilar hot spots; and Type E: hilar hot spots). The deposition patterns of restrictive pulmonary diseases were markedly abnormal as well as obstructive pulmonary diseases. The deposition patterns showed mainly Types C, D and E in obstructive pulmonary diseases, Type B in restrictive pulmonary diseases. The deposition patterns showed mainly Type E in pulmonary emphysema, Types C and D in diffuse panbronchiolitis, Types A, B and C in chronic bronchitis, Type B in idiopathic interstitial pneumonia interstitial pneumonia due to collagen vascular disease, Types B and C in pulmonary asbestosis. The deposition patterns correlated well with %FEV{sub 1.0} which was a good indicator of the severity of obstructive pulmonary diseases and restrictive pulmonary diseases. Furthermore, the mean %FEV{sub 1.0} in obstructive pulmonary diseases was nearly equal to the mean %FEV{sub 1.0} in restrictive pulmonary diseases in each type of the deposition patterns. (J.P.N.).

  18. Cancer mortality and occupational exposure to aromatic amines and inhalable aerosols in rubber tire manufacturing in Poland.

    NARCIS (Netherlands)

    de Vocht, F.; Sobala, W.; Wilczynska, U.; Kromhout, H.; Szeszenia-Dabrowska, N.; Peplonska, B.

    2009-01-01

    AIM: Most data on carcinogenic risk in the rubber industry are based on data from Western countries. This study assessed cancer risks in a retrospective cohort in a Polish tire manufacturing plant, relying on quantified exposure to inhalable aerosols and aromatic amines instead of job titles or

  19. Inhalants

    Science.gov (United States)

    ... uses inhalants may be unable to learn new things or may have a hard time carrying on simple conversations. If the cerebral ... get drugs on the street, it is really hard to know what you get, Sometimes, ... put in, all sorts of things could happen. And other times, one might get ...

  20. Antagonist effect of interferon-γ aerosol inhalation on pulmonary remodeling after γ-ray irradiation

    International Nuclear Information System (INIS)

    Li Ming; Song Liangwen; Wang Shaoxia; Diao Ruiying; Xu Xinping; Luo Qingliang

    2008-01-01

    Objective: To observe the antagonistic effect of interferon-y aerosol inhalation on pulmonary remodeling after γ-ray irradiation, and explore its mechanisms. Methods: The Wistar rats were randomly divided into irradiation control group and irradiation + Interferon-γ antagonist group, which proceeded IFN-γ aerosol inhalation 3 days before 20 Gy 60 Co γ-ray irradiation, then were sacrificed at 10, 20, 30 days after irradiation. Conventional histopathological sections of lung tissue were prepared, which were stained immunohistochemically for α-SMA and Sirius red. The contents of collagen IV were determined by Western blot. The expression of MMP-2, MMP-9 and TIMP-1 in lung homogenate was detected by ELISA. Results: The widen degrees of interalveolar septum, the deposition of collagen I, III, and the expression of α-SMA decreased significantly in IFN-γ treatment group as compared with those in the irradiation control group. The expression of collagen IV appeared an elevation trend, but this phenomenon attenuated after IFN-γ was used. The levels of MMP-2 and TIMP-1 decreased 10 days after administration with IFN-γ but the opposite trend appeared for MMP- 9. The expression of MMP-2, MMP-9 and TIMP-1 decreased 30 days after administration with IFN-γ. Conclusion: IFN-γ is effective in alleviating pulmonary injuries induced by irradiation in rats, possibly by decreasing the expression of TIMP-1 to relieve the inhibition to MMP-9, then degrading collagen IV to antagonize remodeling after lung injury. (authors)

  1. Quantitative evaluation of inhaled radioactive aerosol deposition patterns in the lungs in obstructive airways disease

    Energy Technology Data Exchange (ETDEWEB)

    Teshima, Takeo; Isawa, Toyoharu; Hirano, Tomio; Ebina, Akio; Shiraishi, Koichiro; Konno, Kiyoshi

    1985-12-01

    Uneven distribution of inhaled aerosol in the lungs is the characteristics of obstructive airways disease such as chronic bronchitis and pulmonary emphysema, and has been classified typically into peripheral and central deposition patterns, respectively by visual inspection, whereas in the normal the distribution is homogeneous throughout the lungs. The purpose of the present study was to analyse the distribution of inhaled radioactivity in the lungs by way of matrixes by a computer. The seemingly homogeneous distribution pattern in normal subjects has been found to indicate a gradual change in count profile between the neighboring matrixes. The peripheral pattern indicates the patchy presence of small number of matrixes with excessive radioactivity throughout the lungs, and the central pattern, the presence of matrixes of excessive radioactivity along the major central airways forming a comma-like configuration superimposed on the peripheral pattern. Our computer analysis has a potentiality to characterize obstructive airways disease for a better understanding of their pathophysiology, which is not feasible by a simple visual inspection of images on a polaroid picture.

  2. Quantitative analysis and design of a spray aerosol inhaler. Part 1: effects of dilution air inlets and flow paths.

    Science.gov (United States)

    Longest, P Worth; Hindle, Michael

    2009-09-01

    The objective of this study was to evaluate the effects of modifying inhaler design variables on aerosol drug deposition within the mouthpiece for a representative spray system using a quantitative analysis and design approach. Capillary aerosol generation (CAG) was selected as a model spray aerosol system in conjunction with four prototype inhaler body and mouthpiece combinations. In vitro experiments were used to determine drug deposition in the mouthpiece and induction port. Validated computational fluid dynamics (CFD) simulations were implemented to establish relationships between design variables, transport characteristics, and aerosol drug deposition. Results of this study indicated that both the size of the upstream dilution air inlets and the flow pathway configuration near the spray nozzle significantly influenced aerosol transport and deposition. CFD results showed that the primary transport characteristics associated with drug deposition were turbulence intensity and the effective diameter of the mouthpiece. Strong quantitative correlations were developed between the identified transport characteristics and mouthpiece drug deposition. Based on quantitative analysis and design, turbulence intensity and effective mouthpiece diameter were identified as key transport characteristics within the design space that directly influenced aerosol deposition and may be used to predict and optimize drug delivery to the patient.

  3. A study of the comparison between human and animal excretion data following inhalation exposure to plutonium 238 oxide aerosols

    International Nuclear Information System (INIS)

    Moss, W.D.; Martinez, G.; Gautier, M.A.

    1985-01-01

    Bioassay urine samples obtained since 1971 from eight Los Alamos employees, accidentally exposed by inhalation to high-fired plutonium-238 oxide aerosols, were studied and compared with excretion data obtained from Beagle dogs exposed to /sup 238/PuO/sub 2/ aerosols. The early period Pu human excretion data from the inhalation exposure were unexpected and were unlike previously studied occupational exposure urinary data obtained at Los Alamos. The initial urine samples collected on day one were below the detection limits of the analytical method (0.01 pCi). Within thirty days, however, detectible concentrations of Pu were measured in the urine for several of the exposed personnel. The amounts of Pu excreted continued to increase in each of the cases throughout the first year and the individual patterns of Pu excretion were similar. The human urinary excretion data was compared with similar excretion data obtained from an animal study conducted by the Inhalation Toxicology Research Institute (Me81). In the animal study, Beagle dogs received inhalation exposure to one of three sizes of monodisperse of polydisperse aerosol of /sup 238/PuO/sub 2/. Periodic sacrifice of pairs of dogs during the 4 years after the inhalation exposure provided data on the retention, translocation and mode of excretion of /sup 238/Pu. The comparison of human and animal /sup 238/Pu excretion data supported the observation that the excretion data were similar between the two species and that the animal excretion models can be applied to predict the human /sup 238/Pu excretion following inhalation exposure to high-fired oxides of /sup 238/Pu

  4. Changes of indoor aerosol characteristics and their associated variation on the dose conversion factor due to radon progeny inhalation

    International Nuclear Information System (INIS)

    Tokonami, Shinji; Ishikawa, Tetsuo; Yonehara, Hidenori; Yamada, Yuji; Matsuzawa, Takao; Iimoto, Takeshi

    2003-01-01

    Since the dose conversion factor (hereafter called DCF) due to radon progeny inhalation is strongly dominated by aerosol characteristics in the environment, it is important to understand the air quality for accurate dose assessment. Thus temporal variations on aerosol concentration, its particle size and its related airborne radioactivities were continuously measured in an actual indoor environment with a relatively high radon concentration. The following human activities were added during the observation period: air-conditioning, removal of aerosol with an air cleaner and ventilation. DCFs based on these activities were evaluated with the latest International Commission of Radiological Protection (ICRP) respiratory tract model and were compared among them. Consequently, the present study has shown that operation of air cleaner enhanced the DCF critically because the unattached fraction increased significantly due to removal of aerosols. (author)

  5. The inhalation of insoluble iron oxide particles in the sub-micron ranges. Part II - Plutonium-237 labelled aerosols

    International Nuclear Information System (INIS)

    Waite, D.A.; Ramsden, D.

    1971-10-01

    The results of a series of inhalation studies using iron oxide particles in the size range 0.1 to 0.3 um (count median diameter) are described. In this series the aerosols were labelled with plutonium 237. In vivo detection, excretion analysis and crude location studies were obtainable and the results compared to the earlier studies using chromium 51 labelled aerosols. Plutonium 237 can be considered as a simulator for plutonium 239 and attempts are made to extrapolate the results to the problem of the estimation of plutonium 239 in the human lung. (author)

  6. Evaluation of IOM personal sampler at different flow rates.

    Science.gov (United States)

    Zhou, Yue; Cheng, Yung-Sung

    2010-02-01

    The Institute of Occupational Medicine (IOM) personal sampler is usually operated at a flow rate of 2.0 L/min, the rate at which it was designed and calibrated, for sampling the inhalable mass fraction of airborne particles in occupational environments. In an environment of low aerosol concentrations only small amounts of material are collected, and that may not be sufficient for analysis. Recently, a new sampling pump with a flow rate up to 15 L/min became available for personal samplers, with the potential of operating at higher flow rates. The flow rate of a Leland Legacy sampling pump, which operates at high flow rates, was evaluated and calibrated, and its maximum flow was found to be 10.6 L/min. IOM samplers were placed on a mannequin, and sampling was conducted in a large aerosol wind tunnel at wind speeds of 0.56 and 2.22 m/s. Monodisperse aerosols of oleic acid tagged with sodium fluorescein in the size range of 2 to 100 microm were used in the test. The IOM samplers were operated at flow rates of 2.0 and 10.6 L/min. Results showed that the IOM samplers mounted in the front of the mannequin had a higher sampling efficiency than those mounted at the side and back, regardless of the wind speed and flow rate. For the wind speed of 0.56 m/s, the direction-averaged (the average value of all orientations facing the wind direction) sampling efficiency of the samplers operated at 2.0 L/min was slightly higher than that of 10.6 L/min. For the wind speed of 2.22 m/s, the sampling efficiencies at both flow rates were similar for particles < 60 microm. The results also show that the IOM's sampling efficiency at these two different flow rates follows the inhalable mass curve for particles in the size range of 2 to 20 microm. The test results indicate that the IOM sampler can be used at higher flow rates.

  7. Ferrets develop fatal influenza after inhaling small particle aerosols of highly pathogenic avian influenza virus A/Vietnam/1203/2004 (H5N1

    Directory of Open Access Journals (Sweden)

    Sosna William A

    2010-09-01

    Full Text Available Abstract Background There is limited knowledge about the potential routes for H5N1 influenza virus transmission to and between humans, and it is not clear whether humans can be infected through inhalation of aerosolized H5N1 virus particles. Ferrets are often used as a animal model for humans in influenza pathogenicity and transmissibility studies. In this manuscript, a nose-only bioaerosol inhalation exposure system that was recently developed and validated was used in an inhalation exposure study of aerosolized A/Vietnam/1203/2004 (H5N1 virus in ferrets. The clinical spectrum of influenza resulting from exposure to A/Vietnam/1203/2004 (H5N1 through intranasal verses inhalation routes was analyzed. Results Ferrets were successfully infected through intranasal instillation or through inhalation of small particle aerosols with four different doses of Influenza virus A/Vietnam/1203/2004 (H5N1. The animals developed severe influenza encephalomyelitis following intranasal or inhalation exposure to 101, 102, 103, or 104 infectious virus particles per ferret. Conclusions Aerosolized Influenza virus A/Vietnam/1203/2004 (H5N1 is highly infectious and lethal in ferrets. Clinical signs appeared earlier in animals infected through inhalation of aerosolized virus compared to those infected through intranasal instillation.

  8. Removal of inhaled industrial mixed oxide aerosols from Beagle dogs by lung lavage and chelation therapy

    International Nuclear Information System (INIS)

    Muggenburg, B.A.; Mewhinney, J.A.; Eidson, A.F.; Guilmette, R.A.

    1978-01-01

    An experiment was conducted in 15 adult Beagle dogs to evaluate lung lavage and chelation therapy for the removal of inhaled particles of mixed actinide oxides. The dogs were divided into three groups of five dogs each. Each group was exposed to an aerosol from a different industrial process. Group 1 was exposed to mixed oxide material which had been calcined at 750 0 C collected from a ball milling process. Group 2 was exposed to mixed oxide material from a centerless grinding operation which had been previously heat treated to 1750 0 C. The third group was exposed to 239 PuO 2 not containing uranium from a V-blending procedure which had been heat treated at 850 0 C. After exposure, three dogs in each group were given ten lung lavages and 18 intravenous injections of calcium trisodium diethylenetriaminepentaacetate (DTPA). All dogs were sacrificed 64 days after inhalation exposure. The tissues were radioanalyzed for plutonium and americium. Fluorimetric analyses for uranium in the tissues are in progress. The urine, feces and lavage fluid are also being analyzed for plutonium, americium and uranium. The distribution of plutonium and americium expressed as percentages of the sacrifice body burden was similar in the tissues of the treated and unteated dogs. The lungs contained most of the radionuclides with a small amount in the liver, skeleton and tracheobronchial lymph nodes. The percentage of the sacrifice body burden of americium and plutonium that was present in the lung was less in the treated dogs and was higher in the TBLN's and skeleton than in the untreated dogs. The ratio of Pu/Am was higher in the lungs than in the original material obtained from the industrial sites suggesting a shorter retention time for americium than plutonium to 64 days in the dog

  9. The effect of actuator nozzle designs on the electrostatic charge generated in pressurised metered dose inhaler aerosols.

    Science.gov (United States)

    Chen, Yang; Young, Paul M; Fletcher, David F; Chan, Hak Kim; Long, Edward; Lewis, David; Church, Tanya; Traini, Daniela

    2015-04-01

    To investigate the influence of different actuator nozzle designs on aerosol electrostatic charges and aerosol performances for pressurised metered dose inhalers (pMDIs). Four actuator nozzle designs (flat, curved flat, cone and curved cone) were manufactured using insulating thermoplastics (PET and PTFE) and conducting metal (aluminium) materials. Aerosol electrostatic profiles of solution pMDI formulations containing propellant HFA 134a with different ethanol concentration and/or model drug beclomethasone dipropionate (BDP) were studied using a modified electrical low-pressure impactor (ELPI) for all actuator designs and materials. The mass of the deposited drug was analysed using high performance liquid chromatography (HPLC). Both curved nozzle designs for insulating PET and PTFE actuators significantly influenced aerosol electrostatics and aerosol performance compared with conducting aluminium actuator, where reversed charge polarity and higher throat deposition were observed with pMDI formulation containing BDP. Results are likely due to the changes in plume geometry caused by the curved edge nozzle designs and the bipolar charging nature of insulating materials. This study demonstrated that actuator nozzle designs could significantly influence the electrostatic charges profiles and aerosol drug deposition pattern of pMDI aerosols, especially when using insulating thermoplastic materials where bipolar charging is more dominant.

  10. Late-occurring pulmonary pathologies following inhalation of mixed oxide (uranium + plutonium oxide) aerosol in the rat.

    Science.gov (United States)

    Griffiths, N M; Van der Meeren, A; Fritsch, P; Abram, M-C; Bernaudin, J-F; Poncy, J L

    2010-09-01

    Accidental exposure by inhalation to alpha-emitting particles from mixed oxide (MOX: uranium and plutonium oxide) fuels is a potential long-term health risk to workers in nuclear fuel fabrication plants. For MOX fuels, the risk of lung cancer development may be different from that assigned to individual components (plutonium, uranium) given different physico-chemical characteristics. The objective of this study was to investigate late effects in rat lungs following inhalation of MOX aerosols of similar particle size containing 2.5 or 7.1% plutonium. Conscious rats were exposed to MOX aerosols and kept for their entire lifespan. Different initial lung burdens (ILBs) were obtained using different amounts of MOX. Lung total alpha activity was determined by external counting and at autopsy for total lung dose calculation. Fixed lung tissue was used for anatomopathological, autoradiographical, and immunohistochemical analyses. Inhalation of MOX at ILBs ranging from 1-20 kBq resulted in lung pathologies (90% of rats) including fibrosis (70%) and malignant lung tumors (45%). High ILBs (4-20 kBq) resulted in reduced survival time (N = 102; p inhalation result in similar risk for development of lung tumors as compared with industrial plutonium oxide.

  11. Evaluation of Electronic Cigarette Liquids and Aerosol for the Presence of Selected Inhalation Toxins

    Science.gov (United States)

    Kistler, Kurt A.; Gillman, Gene; Voudris, Vassilis

    2015-01-01

    Introduction: The purpose of this study was to evaluate sweet-flavored electronic cigarette (EC) liquids for the presence of diacetyl (DA) and acetyl propionyl (AP), which are chemicals approved for food use but are associated with respiratory disease when inhaled. Methods: In total, 159 samples were purchased from 36 manufacturers and retailers in 7 countries. Additionally, 3 liquids were prepared by dissolving a concentrated flavor sample of known DA and AP levels at 5%, 10%, and 20% concentration in a mixture of propylene glycol and glycerol. Aerosol produced by an EC was analyzed to determine the concentration of DA and AP. Results: DA and AP were found in 74.2% of the samples, with more samples containing DA. Similar concentrations were found in liquid and aerosol for both chemicals. The median daily exposure levels were 56 μg/day (IQR: 26–278 μg/day) for DA and 91 μg/day (IQR: 20–432 μg/day) for AP. They were slightly lower than the strict NIOSH-defined safety limits for occupational exposure and 100 and 10 times lower compared with smoking respectively; however, 47.3% of DA and 41.5% of AP-containing samples exposed consumers to levels higher than the safety limits. Conclusions: DA and AP were found in a large proportion of sweet-flavored EC liquids, with many of them exposing users to higher than safety levels. Their presence in EC liquids represents an avoidable risk. Proper measures should be taken by EC liquid manufacturers and flavoring suppliers to eliminate these hazards from the products without necessarily limiting the availability of sweet flavors. PMID:25180080

  12. Inhalation toxicology of industrial plutonium and uranium oxide aerosols I. Physical chemical characterization

    International Nuclear Information System (INIS)

    Eidson, A.F.; Mewhinney, J.A.

    1978-01-01

    In the fabrication of mixed plutonium and uranium oxide fuel, large quantities of dry powders are processed, causing dusty conditions in glove box enclosures. Inadvertent loss of glove box integrity or failure of air filter systems can lead to human inhalation exposure. Powdered samples and aerosol samples of these materials obtained during two fuel fabrication process steps have been obtained. A regimen of physical chemical tests of properties of these materials has been employed to identify physical chemical properties which may influence their biological behavior and dosimetry. Materials to be discussed are 750 deg. C heat-treated, mixed uranium and plutonium oxides obtained from the ball milling operation and 1750 deg. C heat-treated, mixed uranium and plutonium oxides obtained from the centerless grinding of fuel pellets. Results of x-ray diffraction studies have shown that the powder generated by the centerless grinding of fuel pellets is best described as a solid solution of UO x and PuO x consistent with its temperature history. In vitro dissolution studies of both mixed oxide materials indicate a generally similar dissolution rate for both materials. In one solvent, the material with the higher temperature history dissolves more rapidly. The x-ray diffraction and in vitro dissolution results as well as preliminary results of x-ray photoelectron spectroscopic analyses will be compared and the implications for the associated biological studies will be discussed. (author)

  13. Age-related differences in pulmonary inflammatory responses to JP-8 jet fuel aerosol inhalation.

    Science.gov (United States)

    Wang, S; Young, R S; Witten, M L

    2001-02-01

    Our previous studies have demonstrated that JP-8 jet fuel aerosol inhalation induced lung injury and dysfunction. To further examine JP-8 jet fuel-induced inflammatory mechanisms, a total of 40 male C57BL/6 mice (young, 3.5 months; adult, 12 months; half in each age group) were randomly assigned to the exposure or control groups. Mice were nose-only exposed to room air or atmospheres of 1000 mg/m3 JP-8 jet fuel for 1 h/day for 7 days. Lung injury was assessed by pulmonary mechanics, respiratory permeability, lavaged cell profile, and chemical mediators in bronchoalveolar lavage fluid (BALF). The young and adult mice exposed to JP-8 jet fuel had similar values with regards to increased lung dynamic compliance, lung permeability, BALF cell count, and decreased PGE2. However, there were several different responses between the young-versus-adult mice with respect to BALF cell differential, TNF-alpha, and 8-iso-PGF2,, levels after exposure to JP-8 jet fuel. These data suggest that JP-8 jet fuel may have different inflammatory mechanisms leading to lung injury and dysfunction in the younger-versus-adult mice.

  14. Factors affecting the efficiency of aerosolized salbutamol delivery via a metered dose inhaler and equine spacer device.

    Science.gov (United States)

    Pirie, R S; McGorum, B C; Owen, C; Carr, O; Oakley, H; McLachlan, G

    2017-06-01

    Despite frequent use of metered dose inhalers (MDIs) and spacers in equine practice, limited information exists on the efficiency of aerosol delivery using such devices. We determined the particle size distribution within an MDI-generated salbutamol aerosol delivered via an equine spacer using 'best practice' delivery technique and assessed the effect of variations in MDI use technique (shaking prior to each actuation, rapid repetitive actuations, and MDI angulation) on aerosol delivery efficiency. Under optimal conditions, only 53(±18) μg salbutamol per 100 μg actuation was delivered beyond the spacer. Although this aerosol had a high [89.6% (±2.4)] fine particle (aerodynamic diameter [2.52 (±0.29) μm], and particle size variability [geometric SD - 1.66 (±0.16) μm], within all particle size fractions, there was a high coefficient of variance (31-79%) of the percentage salbutamol delivered between experimental runs, thus impeding any effort to predict drug delivery to the patient during equine inhalation therapy. Despite observable trends and with the exception of minor statistically significant changes in the least abundant particle sizes, none of the deviations from a 'best practice' delivery technique significantly altered the relative salbutamol delivery beyond the spacer, a finding which has potential relevance with regard to maintaining user compliance. © 2016 John Wiley & Sons Ltd.

  15. Tumor production in Syrian hamsters following inhalation of PuO2--ZrO2 aerosol

    International Nuclear Information System (INIS)

    Thomas, R.G.; Smith, D.M.

    1978-01-01

    Syrian golden hamsters of both sexes were exposed to aerosols of ZrO 2 containing PuO 2 . The starting material in the aerosol generator also had a small amount of 57 Co added as a tracer. The mixture of all three constituents was nebulized and the droplets passed through a heating column at 1000 0 C. Aerosol sampling was accomplished with a cascade impactor and electrostatic precipitator. The median aerodynamic diameters in all inhalation runs were approximately 2 μm with a geometric standard deviation of 2. One exposed group of 60 hamsters had 6-day lung burdens averaging 100 nCi. This group had a lung tumor incidence of 44% with an even distribution of adenomas and carcinomas. Two other groups had average 6-day lung burdens of 80 to 90 nCi plus 55 nCi of intravenously injected spheres localized in the lung. These animals had tumor incidences of approximately 30%

  16. Proceedings of the 1998 Scientific Conference on Obscuration and Aerosol Research

    National Research Council Canada - National Science Library

    Coverstone, Amy

    1999-01-01

    ...: Aerosol Particle Generation and Dynamics, Aerosol Characterization Methods-Aerosol Samplers and Collectors, Preparing, Aerosolizing and Characterizing Erwinia Herbicola, and Optical Properties of Aerosols...

  17. Capstone Depleted Uranium Aerosols: Generation and Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Parkhurst, MaryAnn; Szrom, Fran; Guilmette, Ray; Holmes, Tom; Cheng, Yung-Sung; Kenoyer, Judson L.; Collins, John W.; Sanderson, T. Ellory; Fliszar, Richard W.; Gold, Kenneth; Beckman, John C.; Long, Julie

    2004-10-19

    In a study designed to provide an improved scientific basis for assessing possible health effects from inhaling depleted uranium (DU) aerosols, a series of DU penetrators was fired at an Abrams tank and a Bradley fighting vehicle. A robust sampling system was designed to collect aerosols in this difficult environment and continuously monitor the sampler flow rates. Aerosols collected were analyzed for uranium concentration and particle size distribution as a function of time. They were also analyzed for uranium oxide phases, particle morphology, and dissolution in vitro. The resulting data provide input useful in human health risk assessments.

  18. Regional and global atmospheric aerosol studies using the ''Gent'' stacked filter unit sampler and other aerosol collectors, with multi-elemental analysis of the samples by nuclear-related analytical techniques

    International Nuclear Information System (INIS)

    Maenhaut, W.; Francois, F.; Salma, I.; Cafmeyer, J.; Gilot, C.

    1994-01-01

    The ''Gent'' staked filter unit sampler and other collection devices are used in regional and global scale studies on the tropospheric atmospheric aerosols, its composition, sources and fate. The aerosol samples are analyzed by particle-induced X-ray emission analysis, instrumental neutron activation analysis, ion chromatography, a light reflectance technique (for determining black carbon), and gravimetry (for measuring the particular mass). In evaluating the data, use is made of receptor modelling techniques, transport models and wind sector analysis, and also of air mass trajectories and other meteorological information. Preliminary results from a long-term study in southern Norway are presented. It is suggested that the anthropogenic and soil dust aerosol components are mainly adverted to southern Norway by long-range transport and that the major fraction of the submicrometer particle mass is from anthropogenic origin. Preliminary results are also presented for an intensive study in southern Africa. On the basis of the data for two sites (about 40 km apart) in the Kruger National Park it was concluded that regionally representative aerosol samples were collected and that the biomass burning products account for more than 50% of the fine particle mass. Finally, our plans for future work are given. (author). 70 refs, 4 figs, 1 tab

  19. Functional state of the bronchopulmonary system in Mayak nuclear workers inhaled plutonium-239 aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Belyaeva, Z.; Grigoryeva, E.; Khokhryakov, V. [Southern Urals Biophysics Institute, Ozyorsk (Russian Federation)

    2006-07-01

    Full text of publication follows: The current system of the individual and collective protection facilities for nuclear personnel permits decreasing the radiation dose from internal emitters at the most. At the same time, specific production conditions do not exclude possible inhalation of plutonium-239 aerosols. As the lung is the critical organ for this isotope, the study of respiratory function is aimed at detecting of pre-clinical lung pathology. Early detection of internal exposure effects on functional state of respiratory apparatus is difficult due to a number of confounding actors of non-radiation nature, one of which is smoking. Functional state of bronchopulmonary system was studied in 386 males, workers of the first Russian nuclear facility. 1198 examinations were carried out during medical inspection as well as hospitalization for routine preventive inspection. Most of males (39.4%) started working at the age of 21-26 years and 27.2% at the age of 20 years. The main factors of occupational exposure were exposure to plutonium-239 aerosols and the external gamma -rays. The absorbed dose to lungs from incorporated plutonium-239 was 0-435.8 c Gy. Whole-body external gamma dose varied from 0 to 382 c Gy at the examination. Individual dosimetry data were provided by the Mayak Radiation Safety Department and Internal Dosimetry Laboratory of the Southern Urals Biophysics Institute. While studying respiratory function, the most informative indices characterizing the state of lung tissue and tracheobronchial system such as vital capacity inspiration, forced expiratory volume, forced inspiratory volume, test Tiffno, diffusion capacity, characteristics of the flow vs. volume of the forced vital capacity inspiration curve, and resistance were used. Analysis was done separately for smokers and nonsmokers. Smoking index, i.e. product of number of smoked cigarettes per day and number of years of smoking was considered an integral value. The study did not reveal the

  20. Functional state of the bronchopulmonary system in Mayak nuclear workers inhaled plutonium-239 aerosols

    International Nuclear Information System (INIS)

    Belyaeva, Z.; Grigoryeva, E.; Khokhryakov, V.

    2006-01-01

    Full text of publication follows: The current system of the individual and collective protection facilities for nuclear personnel permits decreasing the radiation dose from internal emitters at the most. At the same time, specific production conditions do not exclude possible inhalation of plutonium-239 aerosols. As the lung is the critical organ for this isotope, the study of respiratory function is aimed at detecting of pre-clinical lung pathology. Early detection of internal exposure effects on functional state of respiratory apparatus is difficult due to a number of confounding actors of non-radiation nature, one of which is smoking. Functional state of bronchopulmonary system was studied in 386 males, workers of the first Russian nuclear facility. 1198 examinations were carried out during medical inspection as well as hospitalization for routine preventive inspection. Most of males (39.4%) started working at the age of 21-26 years and 27.2% at the age of 20 years. The main factors of occupational exposure were exposure to plutonium-239 aerosols and the external gamma -rays. The absorbed dose to lungs from incorporated plutonium-239 was 0-435.8 c Gy. Whole-body external gamma dose varied from 0 to 382 c Gy at the examination. Individual dosimetry data were provided by the Mayak Radiation Safety Department and Internal Dosimetry Laboratory of the Southern Urals Biophysics Institute. While studying respiratory function, the most informative indices characterizing the state of lung tissue and tracheobronchial system such as vital capacity inspiration, forced expiratory volume, forced inspiratory volume, test Tiffno, diffusion capacity, characteristics of the flow vs. volume of the forced vital capacity inspiration curve, and resistance were used. Analysis was done separately for smokers and nonsmokers. Smoking index, i.e. product of number of smoked cigarettes per day and number of years of smoking was considered an integral value. The study did not reveal the

  1. Sampler bias -- Phase 1

    International Nuclear Information System (INIS)

    Blanchard, R.J.

    1995-01-01

    This documents Phase 1 determinations on sampler induced bias for four sampler types used in tank characterization. Each sampler, grab sampler or bottle-on-a-string, auger sampler, sludge sampler and universal sampler, is briefly discussed and their physical limits noted. Phase 2 of this document will define additional testing and analysis to further define Sampler Bias

  2. Evaluation and Modification of Commercial Dry Powder Inhalers for the Aerosolization of a Submicrometer Excipient Enhanced Growth (EEG) Formulation

    Science.gov (United States)

    Son, Yoen-Ju; Longest, P. Worth; Tian, Geng; Hindle, Michael

    2013-01-01

    The aim of this study was to evaluate and modify commercial dry powder inhalers (DPIs) for the aerosolization of a submicrometer excipient enhanced growth (EEG) formulation. The optimized device and formulation combination was then tested in a realistic in vitro mouth-throat - tracheobronchial (MT-TB) model. An optimized EEG submicrometer powder formulation, consisting of albuterol sulfate (drug), mannitol (hygroscopic excipient), L-leucine (dispersion enhancer) and poloxamer 188 (surfactant) in a ratio of 30:48:20:2 was prepared using a Büchi Nano spray dryer. The aerosolization performance of the EEG formulation was evaluated with 5 conventional DPIs: Aerolizer, Novolizer, HandiHaler, Exubera and Spiros. To improve powder dispersion, the HandiHaler was modified with novel mouth piece (MP) designs. The aerosol performance of each device was assessed using a next generation impactor (NGI) at airflow rates generating a pressure drop of 4 kPa across the DPI. In silico and in vitro deposition and hygroscopic growth of formulations was studied using a MT-TB airway geometry model. Both Handihaler and Aerolizer produced high emitted doses (ED) together with a significant submicrometer aerosol fraction. A modified HandiHaler with a MP including a three-dimensional (3D) array of rods (HH-3D) produced a submicrometer particle fraction of 38.8% with a conventional fine particle fraction (% <5µm) of 97.3%. The mass median diameter (MMD) of the aerosol was reduced below 1 µm using this HH-3D DPI. The aerosol generated from the modified HandiHaler increased to micrometer size (2.8 µm) suitable for pulmonary deposition, when exposed to simulated respiratory conditions, with negligible mouth-throat (MT) deposition (2.6 %). PMID:23608613

  3. Inhalation toxicology of diesel fuel obscurant aerosol in Sprague-Dawley rats. Final report, Phase 3, subchronic exposures

    Energy Technology Data Exchange (ETDEWEB)

    Lock, S.; Dalbey, W.; Schmoyer, R.; Griesemer, R.

    1984-12-01

    Inhalation exposures were performed twice per week, for 13 weeks, to determine whether there was any potential toxicity to rats of comparatively low concentrations of a condensation aerosol from diesel fuel. Changes in breathing frequency and the response of animals to a loud sharp sound (startle response) were measured in selected animals prior to the start of the exposures, at various time points during the thirteen week exposure period, and at monthly intervals during the recovery period. Assays were performed on selected animals at the end of the exposure period, and again after the two month recovery period. Endpoints included pulmonary function tests, numbers of alveolar free cells, clinical chemistry, hematology, organ weights and histopathology. No mortalities were recorded during the exposure or recovery periods. Slight toxicity occurred at these low aerosol concentrations with the loss in body weight of all treated animals during the exposure period. During the exposure period there were also some slight changes in startle reflex, however, these were apparently acute effects, and there appeared to be no permanent CNS involvement as measured by this endpoint. Immediately post-exposure, the numbers of lavaged alveolar macrophages were slightly elevated in all aerosol exposed animals. Pulmonary function tests, pulmonary gas exchange and dynamic lung tests were all apparently unaffected by these low diesel fuel aerosol exposures. Changes in tissue weights in aerosol exposed animals were minor and the few histopathological lesions were randomly scattered amongst all groups included in this study and were more attributable to the age of the animals than any specific treatment group. No significant cumulative toxicity may be attributed to these diesel fuel aerosol exposures. 14 references, 1 figure, 42 tables.

  4. Total and regional deposition of inhaled aerosols in supine healthy subjects and subjects with mild-to-moderate COPD

    Energy Technology Data Exchange (ETDEWEB)

    Darquenne, Chantal; Lamm, Wayne J.; Fine, Janelle M.; Corley, Richard A.; Glenny, Robb W.

    2016-09-01

    Despite substantial development of sophisticated subject-specific computational models of aerosol transport and deposition in human lungs, experimental validation of predic- tions from these new models is sparse. We collected aerosol retention and exhalation profiles in seven healthy volunteers and six subjects with mild-to-moderate COPD (FEV1 ¼ 50–80%predicted) in the supine posture. Total deposition was measured during continuous breathing of 1 and 2.9 mm-diameter particles (tidal volume of 1 L, flow rate of 0.3 L/s and 0.75 L/s). Bolus inhalations of 1 mm particles were performed to penetration volumes of 200, 500 and 800 mL (flow rate of 0.5 L/s). Aerosol bolus dispersion (H), deposition, and mode shift (MS) were calculated from these data. There was no significant difference in total deposition between healthy subjects and those with COPD. Total deposition increased with increasing particle size and also with increasing flow rate. Similarly, there was no significant difference in aerosol bolus deposition between subject groups. Yet, the rate of increase in dispersion and of decrease in MS with increasing penetration volume was higher in subjects with COPD than in healthy volunteers (H: 0.79870.205 vs. 0.52770.122 mL/mL, p¼ 0.01; MS: - 0.27170.129 vs. - 0.145 70.076 mL/mL, p¼ 0.05) indicating larger ventilation inhomogeneities (based on H) and increased flow sequencing (based on MS) in the COPD than in the healthy group. In conclusion, in the supine posture, deposition appears to lack sensitivity for assessing the effect of lung morphology and/or ventilation distribution alteration induced by mild-to- moderate lung disease on the fate of inhaled aerosols. However, other parameters such as aerosol bolus dispersion and mode shift may be more sensitive parameters for evaluating models of lungs with moderate disease.

  5. Cancer mortality and occupational exposure to aromatic amines and inhalable aerosols in rubber tire manufacturing in Poland.

    Science.gov (United States)

    de Vocht, Frank; Sobala, Wojciech; Wilczynska, Urszula; Kromhout, Hans; Szeszenia-Dabrowska, Neonila; Peplonska, Beata

    2009-08-01

    Most data on carcinogenic risk in the rubber industry are based on data from Western countries. This study assessed cancer risks in a retrospective cohort in a Polish tire manufacturing plant, relying on quantified exposure to inhalable aerosols and aromatic amines instead of job titles or external comparisons. Cumulative exposure for all exposures was assigned to cohort members based on estimates from a company-specific JEM. Cancer risks associated with cumulative exposure adjusted for co-exposures, gender and year of birth were calculated. Exposure levels were higher for women than for men. Aromatic amine exposure was significantly associated with increased urinary bladder cancer risk (RR=7.32-8.27), depending on exposure level, and prostate cancer at low levels only (RR=5.86). In women, increased risks were found for all cancers (RR=2.50) and of the digestive organs and peritoneum (RR=4.54) at low level only, while an exposure-response association with breast cancer risk was found. Inhalable aerosol exposure was associated with cancers of the liver and intrahepatic bile ducts in a dose-dependent manner, while dose-dependent reduced risks were found for respiratory cancers (most notably the larynx) and cancer of the colon. Increased risks for specific cancer sites in this rubber plant were similar to Western Europe and the US. However, several cancer risks were gender-specific which could relate to higher exposure levels in women or to differences in exposures to chemicals not assessed in this study.

  6. Investigations of the tracheobronchial epithelium of rat after X-ray irradiation and inhalation of 212Pb aerosol

    International Nuclear Information System (INIS)

    Petri, P.

    1981-01-01

    Early reactions of the tracheobronchial epithelium of rats. Be up to 96 h after irradiation have been investigated. Detection of autoradiographically labelled DNA in the basal cells is a measure of the regenerative function of the epithelium. The labelling index is determined on the basis of histological preparations of trachea and bronchi. Each group of animals was exposed to partial irradiation of the thorax of 500 R, 1000 R and 1500 R. A dose-dependent reduction of the labelling index is found with a minimum after 24 h. A further group of animals inhaled 212 Pb aerosol while the control group was given inactive aerosol. The calculations of Hofmann (1969) yield a value of about 170 rad for the trachea and 480 rad for the upper part of the lungs. The labelling index after 12 h is lower than in the animals exposed to 500 R. It is significantly higher in the lobar bronchi. At the time of sacrificing, the labelling index is higher in all regions than the labelling index of 500 R animals. This labelling method enables quantitative determination of DNA synthesis and labelling index after radiation exposure. The study did not indicate the stage of development in which the so-called ''replacement cells'' of the bronchial epithelium are influenced by radiation exposure. Radionuclide inhalation does not affect the bronchial DNA synthesis index as strongly as assumed on the basis of dose estimates. Ater 12 h, the trachea shows a stronger reaction than the bronchi. Explanations are offered. (orig./MG) [de

  7. Study of particulate matter from Primary/Secondary Marine Aerosol and anthropogenic sources collected by a self-made passive sampler for the evaluation of the dry deposition impact on built heritage.

    Science.gov (United States)

    Morillas, Héctor; Maguregui, Maite; García-Florentino, Cristina; Marcaida, Iker; Madariaga, Juan Manuel

    2016-04-15

    Dry deposition is one of the most dangerous processes that can take place in the environment where the compounds that are suspended in the atmosphere can react directly on different surrounding materials, promoting decay processes. Usually this process is related with industrial/urban fog and/or marine aerosol in the coastal areas. Particularly, marine aerosol transports different types of salts which can be deposited on building materials and by dry deposition promotes different decay pathways. A new analytical methodology based on the combined use of Raman Spectroscopy and SEM-EDS (point-by-point and imaging) was applied. For that purpose, firstly evaporated seawater (presence of Primary Marine Aerosol (PMA)) was analyzed. After that, using a self-made passive sampler (SMPS), different suspended particles coming from marine aerosol (transformed particles in the atmosphere (Secondary Marine Aerosol (SMA)) and metallic airborne particulate matter coming from anthropogenic sources, were analyzed. Finally in order to observe if SMA and metallic particles identified in the SMPS can be deposited on a building, sandstone samples from La Galea Fortress (Getxo, north of Spain) located in front of the sea and in the place where the passive sampler was mounted were analyzed. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Analysis of Expedient Field Decontamination Methods for the XMX/2L-MIL High-Volume Aerosol Sampler

    Science.gov (United States)

    2009-12-01

    arsenal. Within the compound, fermented spores were dried and ground into a fine power for use as an aerosol weapon (Alibek, 1999). As a...may account for some of the shortcomings in bleach disinfection noted earlier. Addition of vinegar , a substance which would likely be present in...Furthermore, lowering the pH using vinegar is strongly recommended; it represents a simple, non-toxic method for increasing bleach’s ability to

  9. Effect of aerosol inhalation of ipratropium bromide combined with budesonide and terbutaline on cytokines in children with bronchopneumonia

    Directory of Open Access Journals (Sweden)

    Xiang-Yu Che

    2016-09-01

    Full Text Available Objective: To explore the clinical efficacy of aerosol inhalation of ipratropium bromide combined with budesonide and terbutaline in the treatment of bronchopneumonia in children and the effect on cytokines. Methods: A total of 70 children with bronchopneumonia who were admitted in our hospital from March, 2015 to March, 2016 were included in the study and randomized into the study group and the control group. The patients in the control group were given anti-infection, oxygen inhalation, cough and asthma relieving, acidosis correcting, mask+oxygen driven aerosol inhalation of budesonide (0.5 mg/time and terbutaline (1.0 mg/time, with an oxygen flow rate of 5-7 L/min, 5-10 min every time, twice a day. On the above basis, the patients in the study group were given additional ipratropium bromide (1.0 mg/time. After 7-day treatment, the efficacy was evaluated. The levels of IL-6, TNF-毩, CRP, and WBC before and after treatment were detected. PEF, FVC, and FEV1 before and after treatment were detected. The improvement of clinical symptoms and signs, and the occurrence of adverse reactions were observed. Results: The levels of IL-6, TNF-毩, CRP, and WBC counting after treatment in the two groups were significantly reduced when compared with before treatment (P0.05. Conclusions: Ipratropium bromide combined with budesonide and terbutaline in the treatment of bronchopneumonia in children can rapidly relieve the symptoms, and improve the cytokine level, without obvious adverse reactions; therefore, it deserves to be widely recommended in the clinic.

  10. Aerosol characterization in a gas mantel factory

    International Nuclear Information System (INIS)

    Cunha, K.D. da; Moura, J.J.; Simoes, F.; d'Oliveira, D.; Leite, V.C.B.; Alves, Rex N.; Silva, I.C.M. da.

    1997-01-01

    The workers in a gas mantel manufacturing are exposed to aerosol containing Th and it decay products, which are hazardous to health. For health damage evaluation it is necessary to determine the inhaled particle size, the Th and thoron concentration in the aerosol breathing fraction. A cascade impactor, a stack filter unit and individual air sampler were used to characterize the airborne particles containing Th. The thoron and radon air concentration were determined using Tsivoglu, Kusnetz, Rolle and Two filters methods. (author). 5 refs., 1 fig., 1 tab

  11. ANALYSIS OF RESPIRATORY DEPOSITION OF INHALED PARTICLES FOR DIFFERENT DOSE METRICS: COMPARISON OF NUMBER, SURFACE AREA AND MASS DOSE OF TYPICAL AMBIENT BI-MODAL AEROSOLS

    Science.gov (United States)

    ANALYSIS OF RESPIRATORY DEPOSITION OF INHALED PARTICLES FOR DIFFERENT DOSE METRICS: COMPARISON OF NUMBER, SURFACE AREA AND MASS DOSE OF TYPICAL AMBIENT BI-MODAL AEROSOLS.Chong S. Kim, SC. Hu*, PA Jaques*, US EPA, National Health and Environmental Effects Research Laboratory, ...

  12. Direct gravimetric measurements of the mass of the antarctic aerosol collected by high volume sampler: PM10 summer seasonal variation at Terra Nova Bay.

    Science.gov (United States)

    Truzzi, Cristina; Lambertucci, Luca; Illuminati, Silvia; Annibaldi, Anna; Scarponi, Giuseppe

    2005-01-01

    An on-site procedure was set up for direct gravimetric measurement of the mass of aerosol collected using high volume impactors (aerodynamic size cut point of 10 microm, PM10); this knowledge has hitherto been unavailable. Using a computerized microbalance in a clean chemistry laboratory, under controlled temperature (+/-0.5 degrees C) and relative humidity (+/-1%), continuous, long time filter mass measurements (hours) were carried out before and after exposure, after a 48 h minimun equilibration at the laboratory conditions. The effect of the electrostatic charge was exhausted in 30-60 min, after which stable measurements were obtained. Measurements of filters exposed for 7-11 days (1.13 m3 min(-1)) in a coastal site near Terra Nova Bay (December 2000 - February 2001), gave results for aerosol mass in the order of 10-20 mg (SD approximately 2 mg), corresponding to atmospheric concentrations of 0.52-1.27 microg m(-3). Data show a seasonal behaviour in the PM10 content with an increase during December - early January, followed by a net decrease. The above results compare well with estimates obtained from proxy data for the Antarctic Peninsula (0.30 microg m(-3)), the Ronne Ice Shelf (1.49 microg m(-3)), and the South Pole (0.18 microg m(-3), summer 1974-1975, and 0.37 microg m(-3), average summer seasons 1975-1976 and 1977-1978), and from direct gravimetric measurements recently obtained from medium volume samplers at McMurdo station (downwind 3.39 microg m(-3), upwind 4.15 microg m(-3)) and at King George Island (2.5 microg m(-3), summer, particle diameter <20 microm). This finding opens the way to the direct measurement of the chemical composition of the Antarctic aerosol and, in turn, to a better knowledge of the snow/air relationships as required for the reconstruction of the chemical composition of past atmospheres from deep ice core data.

  13. The variation of organ doses with the particle size and chemical form of an inhaled radioactive aerosol

    International Nuclear Information System (INIS)

    Hunt, B.W.; Adams, N.; Reissland, J.A.

    1979-04-01

    In this report, radiation doses to organs are calculated as a function of the particle size of the inhaled radioactive material. Aerosols with an Activity Median Aerodynamic Diameter (AMAD) from 0.1 μm to 20 μm are considered and doses accumulated by various organs in periods ranging from 1 day to 70 years are given for 65 radionuclides. A computer program is used which calculates the transformations taking place in each organ per curie of inhaled nuclide from the basic radioactivity and metabolic data. The program also calculates the resulting doses both for the organ in which the transformations occur and from penetrating radiation emitted as a result of transformations in other organs. The effects of particle size and chemical form of the nuclides on the doses received by organs are discussed. Tables of doses accumulated by 10 specific organs and other organs together with effective whole body doses are given for particle sizes 0.1 μm, 1 μm and 10 μm (AMAD). (author)

  14. Formation of charged particles in condensation aerosol generators used for inhalation studies

    International Nuclear Information System (INIS)

    Ramu, M.C.R.; Vohra, K.G.

    1976-01-01

    Formation of charged particles in a condensation aerosol generator has been studied using a charge collector and a mobility analyzer. Measurements carried out using the charge collector show that the number of charged particles increases with an increase in the particle diameter. The number of charged particles measured also depends on the thickness of the sodium chloride coating on the platinum wire used in the aerosol generator for the production of condensation nuclei. It was found that the charged particle concentration increases with decreasing coating thickness. Mobility measurements have shown that the particles are singly and doubly charged. It has been estimated that about 10% of the particles produced in the generator are charged. The mechanism of formation of charged particles in the aerosol generator has been briefly discussed. (author)

  15. Sinonasal inhalation of tobramycin vibrating aerosol in cystic fibrosis patients with upper airway Pseudomonas aeruginosa colonization: results of a randomized, double-blind, placebo-controlled pilot study

    Science.gov (United States)

    Mainz, Jochen G; Schädlich, Katja; Schien, Claudia; Michl, Ruth; Schelhorn-Neise, Petra; Koitschev, Assen; Koitschev, Christiane; Keller, Peter M; Riethmüller, Joachim; Wiedemann, Baerbel; Beck, James F

    2014-01-01

    Rationale In cystic fibrosis (CF), the paranasal sinuses are sites of first and persistent colonization by pathogens such as Pseudomonas aeruginosa. Pathogens subsequently descend to the lower airways, with P. aeruginosa remaining the primary cause of premature death in patients with the inherited disease. Unlike conventional aerosols, vibrating aerosols applied with the PARI Sinus™ nebulizer deposit drugs into the paranasal sinuses. This trial assessed the effects of vibrating sinonasal inhalation of the antibiotic tobramycin in CF patients positive for P. aeruginosa in nasal lavage. Objectives To evaluate the effects of sinonasal inhalation of tobramycin on P. aeruginosa quantification in nasal lavage; and on patient quality of life, measured with the Sino-Nasal Outcome Test (SNOT-20), and otologic and renal safety and tolerability. Methods Patients were randomized to inhalation of tobramycin (80 mg/2 mL) or placebo (2 mL isotonic saline) once daily (4 minutes/nostril) with the PARI Sinus™ nebulizer over 28 days, with all patients eligible for a subsequent course of open-label inhalation of tobramycin for 28 days. Nasal lavage was obtained before starting and 2 days after the end of each treatment period by rinsing each nostril with 10 mL of isotonic saline. Results Nine patients participated, six initially receiving tobramycin and three placebo. Sinonasal inhalation was well tolerated, with serum tobramycin <0.5 mg/L and stable creatinine. P. aeruginosa quantity decreased in four of six (67%) patients given tobramycin, compared with zero of three given placebo (non-significant). SNOT-20 scores were significantly lower in the tobramycin than in the placebo group (P=0.033). Conclusion Sinonasal inhalation of vibrating antibiotic aerosols appears promising for reducing pathogen colonization of paranasal sinuses and for control of symptoms in patients with CF. PMID:24596456

  16. Early effects of inhaled 239Pu(NO3)4 aerosols in beagle dogs

    International Nuclear Information System (INIS)

    Dagle, G.E.; Ragan, H.A.; Watson, C.R.; Stevens, D.L.; Rowe, S.E.; Madison, R.M.; Wierman, E.L.; Schirmer, R.E.

    1979-01-01

    Beagle dogs given a single inhalation exposure to 239 Pu(NO 3 ) 4 , and observed for life-span dose-effect relationship, died from radiation pneumonitis (4 of 5) at the highest dosage level, 14 to 25 mo postexposure. There were also indications in these dogs of radiation osteosis, characterized by peritrabecular fibrosis. Leukopenia, lymphopenia, neutropenia and decreased numbers of circulating monocytes and eosinophils occurred at the two highest dosage levels, as previously reported

  17. Tumorigenic responses from single or repeated inhalation exposures to relatively insoluble aerosols of Ce-144

    International Nuclear Information System (INIS)

    Boecker, B.B.; Hahn, F.F.; Mauderly, J.L.; McClellan, R.O.

    1980-01-01

    Human occupational or environmental inhalation exposures may involve repeated or chronic exposures, but most laboratory studies of inhaled radionuclides have involved single exposures. This study was designed to compare the biological effects of repeated inhalation exposures of dogs to a relatively insoluble form of 144 Ce with existing data for singly-exposed dogs that had the same cumulative dose to the lungs two years after exposure. To date, the biological effects observed in these repeatedly-exposed dogs have been substantially different from those seen in singly-exposed dogs, particularly during the first 5 years after the initial exposure. Although pulmonary hemangiosarcoma was the prominent biological effect seen in singly-exposed dogs between 2 and 4 years after exposure, no lung tumors were seen during the 5 years after the first of the repeated exposures. This response plus other clinical observations are discussed in relation to the patterns of dose rate and cumulative dose for the different exposure conditions. (H.K.)

  18. Real-world healthcare utilization in asthma patients using albuterol sulfate inhalation aerosol (ProAir® HFA with and without integrated dose counters

    Directory of Open Access Journals (Sweden)

    Kerwin EM

    2017-05-01

    Full Text Available Edward M Kerwin,1 Thomas J Ferro,2 Rinat Ariely,3 Debra E Irwin,4 Ruchir Parikh3 1Clinical Trials Division, Clinical Research Institute of Southern Oregon, PC, Medford, OR, 2Global Medical Affairs, 3Global Health Economics and Outcome Research, Teva Pharmaceuticals, Frazer, PA, 4Outcomes Research, Truven Health Analytics, Durham, NC, USA Background: Accurate tracking of the administered dose of asthma rescue inhalers is critical for optimal disease management and is related to reductions in rates of unscheduled health care utilization in asthma patients. There are few published data on the real-world impact of rescue inhalers with integrated dose counters (IDCs on health care resource utilization (HRU for asthma patients. This study evaluates HRU among users of ProAir® hydrofluoroalkane (HFA (albuterol sulfate inhalation aerosol, with IDC versus without IDC, in asthma patients.Methods: This was a retrospective administrative claims study of asthma patients receiving a new prescription for albuterol inhalation aerosol without IDC during 2 years (January 2011–December 2012 or with IDC during the first full year after IDC implementation in the USA (July 2013–July 2014. Six months of continuous enrollment with medical and prescription drug benefits were required before and after the first prescription during the study period. Data on respiratory-related hospitalizations and emergency department (ED visits were collected during the follow-up period.Results: A total of 135,305 (32% patients used albuterol inhalation aerosol with IDC, and 287,243 (68% patients received albuterol inhalation aerosol without IDC. After adjusting for baseline confounding factors, the odds ratio (OR for experiencing a respiratory-related hospitalization (OR=0.92; 95% confidence interval [CI] 0.88–0.96 or ED visit (OR=0.92; 95% CI 0.90–0.94 was significantly lower among patients using albuterol inhalation aerosol with IDC versus without IDC.Conclusion: In a real

  19. The Inhalation Toxicity of VX Aerosols Assessed in the McNamara Glove Box Facility

    National Research Council Canada - National Science Library

    Carpin, John C; McCaskey, David A; Cameron, Kenneth P

    2005-01-01

    ... in this facility and to serve as a benchmark for ranking the toxicity of other agents. Neat VX challenge aerosols were generated by feeding micro-liter quantities of agent from a loaded syringe to a custom-made air assist atomizer...

  20. In vitro tests for aerosol deposition II: IVIVCs for different dry powder inhalers in normal adults.

    Science.gov (United States)

    Delvadia, Renishkumar; Hindle, Michael; Longest, P Worth; Byron, Peter R

    2013-06-01

    A new in vitro test method for dry powder inhalers (DPIs) was recently found to be predictive of the published in vivo results for Budelin Novolizer. The present study was intended to assess the method's robustness by evaluating correlations between average drug deposition in vitro and in vivo from five different DPIs. In vitro drug deposition from five marketed DPIs was assessed in a realistic physical airway model of a "medium" sized adult in an experimental setup that allowed deposition to be characterized regionally for carefully selected simulated air flow rate versus time profiles. The DPIs studied were Spiriva(®) HandiHaler(®), Relenza(®) Diskhaler(®), Salbutamol Easyhaler(®), Pulmicort(®) Turbuhaler(®), and Foradil(®) Aerolizer(®). In vitro regional deposition results were compared with those reported in the literature in order to create in vitro-in vivo correlations (IVIVCs) for each inhaler. Mean percent total lung deposition (TLD ± SD) in vitro for Spiriva HandiHaler, Relenza Diskhaler, Salbutamol Easyhaler, Pulmicort Turbuhaler, and Foradil Aerolizer were 17.3 ± 1.2, 22.6 ± 1.1, 29.0 ± 1.1, 28.0 ± 3.0, and 21.7 ± 1.2, respectively. These results showed excellent agreement with reported in vivo values, with absolute prediction errors in TLD of ≤ 2% for all DPIs except Relenza Diskhaler. Similarly, in vitro mouth-throat and device deposition results were stoichiometrically comparable to those reported in vivo for all DPIs except Relenza Diskhaler and Turbuhaler. Inspection of the scintigraphy studies for Relenza Diskhaler and Turbohaler revealed possible problems with powder labeling and result interpretation in their in vivo clinical assessments. A characteristic physical airway model representing a medium-sized adult, when coupled to carefully chosen characteristic inhalation maneuvers used in the clinic, produced results that correlated with regional drug deposition estimates from scintigraphy across a group of different DPIs.

  1. Production of lung cancer in mice by inhalation exposure to influenza virus and aerosols of hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Kotin, P; Wiseley, D V

    1963-01-01

    1800 C57 (tumor-resistant) mice were exposed in chambers to washed air, repeated influenza virus, artificial smog with 1 to 2 ppM oxidant (ozonized gasoline), or a combination of smog and influenza. Squamous lesions were produced in flu (11) and flu plus smog (33) groups but not in control or smog only groups. The flu only lesions did not show keratinization, pleomorphism and atypical mitoses, or vascular or lymphatic invasion as did lesions in flu + smog. Use of proliferative stimulus plus carcinogenic hydrocarbon resulted in keratinizing metaplasia and squamous cell carcinoma not previously produced by other inhalation techniques.

  2. Hypoadrenocorticism in beagles exposed to aerosols of plutonium-238 dioxide by inhalation

    International Nuclear Information System (INIS)

    Weller, R.E.; Buschbom, R.L.; Dagle, G.E.

    1996-01-01

    Hypoadrenocorticism, known as Addison's disease in humans, was diagnosed in six beagles after inhalation of at least 1.7 kBq/g lung of 238 PuO 2 . Histological examination of adrenal gland specimens obtained at necropsy revealed marked adrenal cortical atrophy in all cases. Autoadiographs showed only slight α-particle activity. Although the pathogenesis of adrenal cortical atrophy in these dogs is unclear, there is evidence to suggest an automimmune disorder linked to damage resulting from α-particle irradiation to the lymphatic system

  3. Operating manual for Ford's Farm Range air samplers

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.; Halverson, M.A.

    1980-10-01

    An air-sampling program was designed for a target enclosure at the Ford's Farm Range, Aberdeen Proving Ground, Maryland, where the Army test-fires tungsten and depleted-uranium armor penetrators. The primary potential particle inhalation hazard is depleted uranium. The sampling program includes workplace and filtered exhaust air sampling. Conventional isokinetic stack sampling was employed for the filtered exhaust air. Because of the need for rapid monitor response to concentration increases and decreases, conventional radioactive particle monitors were not used. Instead, real-time aerosol monitors employing a light-scattering technique were used for monitors requiring a fast response. For other monitoring functions, piezoelectric and beta-attenuation respirable-particle sampling techniques were used. The application of these technologies to the monitoring of airborne radioactive contaminants is addressed. Sampler installation and operation are detailed

  4. Utilization and development of the portable prototype equipment of lang inhalation with radioactive aerosols

    International Nuclear Information System (INIS)

    Marroni, B.J.; Siegmann, W.

    1986-01-01

    The 99 Tc-Aerosol was obtaneid from coloidal substances using a new apparatus, the 'Aerogama'. This equipment uses a conventional nebulyzer, an O 2 source, a respiratory system with inspiratory/expiratory compartments that are connected by valves and tubes with a one way flow. The environment contaminations is minimal and the 140 KeV energy rays are attenuated in about 93%. It has high utility in nuclear medicine as diagnostic tool applied to some lung diseases. (Author) [pt

  5. Measuring aerosols generated inside armoured vehicles perforated by depleted uranium ammunition

    International Nuclear Information System (INIS)

    Parkhurst, M.A.

    2003-01-01

    In response to questions raised after the Gulf War about the health significance of exposure to depleted uranium (DU), the US Department of Defense initiated a study designed to provide an improved scientific basis for assessment of possible health effects on soldiers in vehicles struck by these munitions. As part of this study, a series of DU penetrators were fired at an Abrams tank and a Bradley fighting vehicle, and the aerosols generated by vehicle perforation were collected and characterised. A robust sampling system was designed to collect aerosols in this difficult environment and monitor continuously the sampler flow rates. The aerosol samplers selected for these tests included filter cassettes, cascade impactors, a five-stage cyclone and a moving filter. Sampler redundancy was an integral part of the sampling system to offset losses from fragment damage. Wipe surveys and deposition trays collected removable deposited particulate matter. Interior aerosols were analysed for uranium concentration and particle size distribution as a function of time. They were also analysed for uranium oxide phases, particle morphology and dissolution in vitro. These data, currently under independent peer review, will provide input for future prospective and retrospective dose and health risk assessments of inhaled or ingested DU aerosols. This paper briefly discusses the target vehicles, firing trajectories, aerosol samplers and instrumentation control systems, and the types of analyses conducted on the samples. (author)

  6. Late effects following inhalation of mixed oxide (U,PuO2) mox aerosol in the rat

    International Nuclear Information System (INIS)

    Griffiths, N.; Van Der Meeren, A.; Fritsch, P.; Maximilien, R.

    2008-01-01

    Exposure to alpha-emitting particles is a potential long-term health risk to workers in nuclear fuel fabrication plants. Mixed Oxide (MOX: U,PuO 2 ) fuels containing low percentages of plutonium obtained from spent nuclear fuels are increasingly employed and in the case of accidental contamination by inhalation or wounds may result in the development of late-occurring pathologies such as lung cancer. However the long term risks particularly with regard to lung cancer are to date unclear. In the case of MOX the risk may indeed be different from that assigned to the individual components, plutonium and uranium. Several factors are influential (i) the dissolution of Pu depends on the physico-chemical properties, for example risk of lung cancer is increased 10 fold after Pu(NO 3 ) 2 as compared with PuO 2 . (ii) The solubility of Pu is variable whether delivered as PuO 2 or contained within MOX. (iii) The risk of cancer appears to increase with spatial homogeneity of the lung alpha dose. The objective of this study was to investigate the long term effects in rat lungs following MOX aerosol inhalation of similar particle size containing 2.5 or 7.1% Pu. Conscious rats were exposed to MOX aerosols using a 'nose-only' system and kept for their entire life (2-3 years). Different Initial Lung Deposits (ILDs) were obtained using different concentrations of the MOX suspension. Lung total alpha activity was determined in vivo at intervals over the study period by external counting as well as at autopsy in order to estimate the total lung dose. Anatomo-pathological and immunohistochemical analyses were performed on fixed lung tissue after euthanasia. The frequencies of lung pathologies and tumours were determined on lung sections at several different levels. In addition, autoradiography of lung sections was performed in order to assess the spatial localisation of a activity. Inhalation of MOX at ILD ranging from 1-20 kBq resulted in lung pathologies (90% of exposed rats

  7. The ''Gent'' stacked filter unit (SFU) sampler for the collection of atmospheric aerosols in two size fractions: Description and instructions for installation and use

    International Nuclear Information System (INIS)

    Maenhaut, W.; Francois, F.; Cafmeyer, J.

    1994-01-01

    This report contains a description and general instructions for the installation and use of the ''Gent'' Stacked Filter Unit (SFU) PM10 sampler. The sampler operates at a flow rate of 16 litres per min. It collects particulates which have an equivalent aerodynamic diameter (EAD) of less than 10 μm in separate ''coarse'' (2-10 μm EAD) and ''fine'' ( 10 μm EAD particles is accomplished by a PM10 pre-impaction stage upstream of the stacked filter cassette. The air is drawn through the sampler by means of a diaphragm vacuum pump, which is enclosed in a special housing together with a needle valve, vacuum gauge, flow meter, volume meter, time switch (for interrupted sampling) and hour meter. A list of manufacturers of the various components of the sampler is also given. (author). 4 figs, 1 tab

  8. NASA's Aerosol Sampling Experiment Summary

    Science.gov (United States)

    Meyer, Marit E.

    2016-01-01

    In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

  9. /sup 239/PuO/sub 2/ aerosol inhalation with emphasis on pulmonary connective tissue modifications

    Energy Technology Data Exchange (ETDEWEB)

    Metivier, H; Masse, R; Nobil' e, D; Lafuma, J

    1975-09-01

    Inhalation studies were undertaken in which plutonium dioxide (/sup 239/PuO/sub 2/) was administered to either unanesthetized Wistar rats or anaesthetized baboons. In both groups of animals some deaths occurred from acute lung damage resulting from cell necrosis particularly to vascular tissue followed by alveolar oedema. At later stages, marked interstitial pneumonitis and interstitial fibrosis occurred and deaths resulted from respiratory insufficiency preceded by high arterial blood pCO/sub 2/ and low pO/sub 2/. In rats as many as 50% of the animals finally developed lung neoplasms but only two such tumors were found in baboons. Attempts were made to correlate biochemical parameters with observed tissue damage and animal mortality.

  10. Relation between aerosol sources and meteorological parameters for inhalable atmospheric particles in Sao Paulo City, Brazil

    Science.gov (United States)

    Andrade, Fatima; Orsini, Celso; Maenhaut, Willy

    Stacked filter units were used to collect atmospheric particles in separate coarse and fine fractions at the Sao Paulo University Campus during the winter of 1989. The samples were analysed by particle-induced X-ray emission (PIXE) and the data were subjected to an absolute principal component analysis (APCA). Five sources were identified for the fine particles: industrial emissions, which accounted for 13% of the fine mass; emissions from residual oil and diesel, explaining 41%; resuspended soil dust, with 28%; and emissions of Cu and of Mg, together with 18%. For the coarse particles, four sources were identified: soil dust, accounting for 59% of the coarse mass; industrial emissions, with 19%; oil burning, with 8%; and sea salt aerosol, with 14% of the coarse mass. A data set with various meteorological parameters was also subjected to APCA, and a correlation analysis was performed between the meteorological "absolute principal component scores" (APCS) and the APCS from the fine and coarse particle data sets. The soil dust sources for the fine and coarse aerosol were highly correlated with each other and were anticorrelated with the sea breeze component. The industrial components in the fine and coarse size fractions were also highly positively correlated. Furthermore, the industrial component was related with the northeasterly wind direction and, to a lesser extent, with the sea breeze component.

  11. Evaluation of physical sampling efficiency for cyclone-based personal bioaerosol samplers in moving air environments.

    Science.gov (United States)

    Su, Wei-Chung; Tolchinsky, Alexander D; Chen, Bean T; Sigaev, Vladimir I; Cheng, Yung Sung

    2012-09-01

    The need to determine occupational exposure to bioaerosols has notably increased in the past decade, especially for microbiology-related workplaces and laboratories. Recently, two new cyclone-based personal bioaerosol samplers were developed by the National Institute for Occupational Safety and Health (NIOSH) in the USA and the Research Center for Toxicology and Hygienic Regulation of Biopreparations (RCT & HRB) in Russia to monitor bioaerosol exposure in the workplace. Here, a series of wind tunnel experiments were carried out to evaluate the physical sampling performance of these two samplers in moving air conditions, which could provide information for personal biological monitoring in a moving air environment. The experiments were conducted in a small wind tunnel facility using three wind speeds (0.5, 1.0 and 2.0 m s(-1)) and three sampling orientations (0°, 90°, and 180°) with respect to the wind direction. Monodispersed particles ranging from 0.5 to 10 μm were employed as the test aerosols. The evaluation of the physical sampling performance was focused on the aspiration efficiency and capture efficiency of the two samplers. The test results showed that the orientation-averaged aspiration efficiencies of the two samplers closely agreed with the American Conference of Governmental Industrial Hygienists (ACGIH) inhalable convention within the particle sizes used in the evaluation tests, and the effect of the wind speed on the aspiration efficiency was found negligible. The capture efficiencies of these two samplers ranged from 70% to 80%. These data offer important information on the insight into the physical sampling characteristics of the two test samplers.

  12. Btk Inhibitor RN983 Delivered by Dry Powder Nose-only Aerosol Inhalation Inhibits Bronchoconstriction and Pulmonary Inflammation in the Ovalbumin Allergic Mouse Model of Asthma.

    Science.gov (United States)

    Phillips, Jonathan E; Renteria, Lorena; Burns, Lisa; Harris, Paul; Peng, Ruoqi; Bauer, Carla M T; Laine, Dramane; Stevenson, Christopher S

    2016-06-01

    In allergen-induced asthma, activated mast cells start the lung inflammatory process with degranulation, cytokine synthesis, and mediator release. Bruton's tyrosine kinase (Btk) activity is required for the mast cell activation during IgE-mediated secretion. This study characterized a novel inhaled Btk inhibitor RN983 in vitro and in ovalbumin allergic mouse models of the early (EAR) and late (LAR) asthmatic response. RN983 potently, selectively, and reversibly inhibited the Btk enzyme. RN983 displayed functional activities in human cell-based assays in multiple cell types, inhibiting IgG production in B-cells with an IC50 of 2.5 ± 0.7 nM and PGD2 production from mast cells with an IC50 of 8.3 ± 1.1 nM. RN983 displayed similar functional activities in the allergic mouse model of asthma when delivered as a dry powder aerosol by nose-only inhalation. RN983 was less potent at inhibiting bronchoconstriction (IC50(RN983) = 59 μg/kg) than the β-agonist salbutamol (IC50(salbutamol) = 15 μg/kg) in the mouse model of the EAR. RN983 was more potent at inhibiting the antigen induced increase in pulmonary inflammation (IC50(RN983) = <3 μg/kg) than the inhaled corticosteroid budesonide (IC50(budesonide) = 27 μg/kg) in the mouse model of the LAR. Inhalation of aerosolized RN983 may be effective as a stand-alone asthma therapy or used in combination with inhaled steroids and β-agonists in severe asthmatics due to its potent inhibition of mast cell activation.

  13. Temporal characteristics of inhalable mercury and arsenic aerosols in the urban atmosphere in southern Taiwan

    Science.gov (United States)

    Tsai, Ying I.; Kuo, Su-Ching; Lin, Yi-Hsuan

    Urban aerosol samples for PM 10 and PM 2.5 were collected during summer (August) and winter (December) 2000 in southern Taiwan (Tainan City) to demonstrate the temporal variations of Hg and As in particulate matter (PM). The mean mass concentrations with standard deviations were 80.0±26.8 μg m -3 for PM 10 and 50.6±16.6 μg m -3 for PM 2.5. The average PM 2.5/PM 10 mass ratio for the two periods combined was 63%, indicating that fine particles were a large portion of PM 10. Particulate samples of Hg and As were analyzed within 2 days following sampling and weighing, because of the highly volatile nature of PM Hg and As. The average Hg and As values in PM 10, PM 2.5 and PM 2.5-10 in summer were significantly lower than those in winter. PM 2.5 Hg constituted 0.34 to 5.8 ng m -3 and PM 2.5-10 Hg 0.05 to 3.1 ng m -3. PM 2.5 As constituted 1.09 to 9.51 ng m -3 and PM 2.5-10 As 0.18 to 4.14 ng m -3. In summer and winter PM 10, the Hg contents showed regular daily variation, with the higher values at daytime and lower values at nighttime, indicating conversion of gaseous Hg to the particulate phase by reaction with atmospheric oxidants under strong solar radiation during the daytime in both summer and winter. PM As behaved similar to Hg in the summer, but in the winter higher concentrations were observed during the nighttime than during the daytime, implying that the stable temperature inversion during winter nighttime caused the accumulation of PM As near the ground. In summer, SE-WSW winds carried As from an As-emitting fossil power plant to the sample area. In a similar vein, NE-WNW winter winds contributed to aerosol Hg, especially in PM 2.5, originating from a waste incinerator located NW of Tainan City.

  14. Lessons learned from case studies of inhalation exposures of workers to radioactive aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, M.D.; Fencl, A.F.; Newton, G.J. [and others

    1995-12-01

    Various Department of Energy requirements, rules, and orders mandate that lessons learned be identified, evaluated, shared, and incorporated into current practices. The recently issued, nonmandatory DOE standard for Development of DOE Lessons Learned Program states that a DOE-wide lessons learned program will {open_quotes}help to prevent recurrences of negative experiences, highlight best practices, and spotlight innovative ways to solve problems or perform work more safely, efficiently, and cost effectively.{close_quotes} Additional information about the lessons learned program is contained in the recently issued DOE handbook on Implementing U.S. Department of Energy Lessons Learned Programs and in October 1995 DOE SAfety Notice on Lessons Learned Programs. This report summarizes work in progress at ITRI to identify lessons learned for worker exposures to radioactive aerosols, and describes how this work will be incorporated into the DOE lessons learned program, including a new technical guide for measuring, modeling, and mitigating airborne radioactive particles. Follow-on work is focusing on preparation of {open_quotes}lessons learned{close_quotes} training materials for facility designers, managers, health protection professionals, line supervisors, and workers.

  15. Lessons learned from case studies of inhalation exposures of workers to radioactive aerosols

    International Nuclear Information System (INIS)

    Hoover, M.D.; Fencl, A.F.; Newton, G.J.

    1995-01-01

    Various Department of Energy requirements, rules, and orders mandate that lessons learned be identified, evaluated, shared, and incorporated into current practices. The recently issued, nonmandatory DOE standard for Development of DOE Lessons Learned Program states that a DOE-wide lessons learned program will open-quotes help to prevent recurrences of negative experiences, highlight best practices, and spotlight innovative ways to solve problems or perform work more safely, efficiently, and cost effectively.close quotes Additional information about the lessons learned program is contained in the recently issued DOE handbook on Implementing U.S. Department of Energy Lessons Learned Programs and in October 1995 DOE SAfety Notice on Lessons Learned Programs. This report summarizes work in progress at ITRI to identify lessons learned for worker exposures to radioactive aerosols, and describes how this work will be incorporated into the DOE lessons learned program, including a new technical guide for measuring, modeling, and mitigating airborne radioactive particles. Follow-on work is focusing on preparation of open-quotes lessons learnedclose quotes training materials for facility designers, managers, health protection professionals, line supervisors, and workers

  16. Biological effects of repeated inhalation exposure of beagle dogs to relatively insoluble aerosols of 144Ce

    International Nuclear Information System (INIS)

    Boecker, B.B.; Hahn, F.F.; Muggenburg, B.A.; McClellan, R.O.; Mauderly, J.L.; Pickrell, J.A.

    1980-01-01

    Beagle dogs were exposed repeatedly to a relatively insoluble form of 144 Ce (in fused aluminosilicate particles) to study the deposition, retention, and long-term biological effects for comparison with data from dogs that were exposed only once to a similar aerosol. Four groups of nine dogs each were exposed once every 8 weeks for 2 years (13 exposures) to achieve specified exposure goals. These goals were: to increase the lung burden by 2.5 μCi 144 Ce/kg body weight with each exposure; to reestablish lung burdens of 9 or 4.5 μCi 144 Ce/kg body weight and to expose controls to fused aluminosilicate particles containing nonradioactive cerium. To date, 19 exposed dogs and 2 control dogs have died or were euthanized. The most prevalent findings to date have been pulmonary carcinomas (7 dogs) and hemangiosarcomas in the tracheobronchial lymph nodes (3 dogs). Observations are continuing on the surviving 8 144 Ce-exposed and 7 control dogs who are now at approximately 2500 days (6.8 years) after the first exposure

  17. Metabolites from inhalation of aerosolized S-8 synthetic jet fuel in rats.

    Science.gov (United States)

    Tremblay, Raphael T; Martin, Sheppard A; Fisher, Jeffrey W

    2011-01-01

    Alternative fuels are being considered for civilian and military uses. One of these is S-8, a replacement jet fuel synthesized using the Fischer-Tropsch process, which contains no aromatic compounds and is mainly composed of straight and branched alkanes. Metabolites of S-8 fuel in laboratory animals have not been identified. The goal of this study was to identify metabolic products from exposure to aerosolized S-8 and a designed straight-chain alkane/polyaromatic mixture (decane, undecane, dodecane, tridecane, tetradecane, pentadecane, naphthalene, and 2-methylnaphthalene) in male Fischer 344 rats. Collected blood and tissue samples were analyzed for 70 straight and branched alcohols and ketones ranging from 7 to 15 carbons. No fuel metabolites were observed in the blood, lungs, brain, and fat following S-8 exposure. Metabolites were detected in the liver, urine, and feces. Most of the metabolites were 2- and 3-position alcohols and ketones of prominent hydrocarbons with very few 1- or 4-position metabolites. Following exposure to the alkane mixture, metabolites were observed in the blood, liver, and lungs. Interestingly, heavy metabolites (3-tridecanone, 2-tridecanol, and 2-tetradecanol) were observed only in the lung tissues possibly indicating that metabolism occurred in the lungs. With the exception of these heavy metabolites, the metabolic profiles observed in this study are consistent with previous studies reporting on the metabolism of individual alkanes. Further work is needed to determine the potential metabolic interactions of parent, primary, and secondary metabolites and identify more polar metabolites. Some metabolites may have potential use as biomarkers of exposure to fuels.

  18. Effect of surface coating with magnesium stearate via mechanical dry powder coating approach on the aerosol performance of micronized drug powders from dry powder inhalers.

    Science.gov (United States)

    Zhou, Qi Tony; Qu, Li; Gengenbach, Thomas; Larson, Ian; Stewart, Peter J; Morton, David A V

    2013-03-01

    The objective of this study was to investigate the effect of particle surface coating with magnesium stearate on the aerosolization of dry powder inhaler formulations. Micronized salbutamol sulphate as a model drug was dry coated with magnesium stearate using a mechanofusion technique. The coating quality was characterized by X-ray photoelectron spectroscopy. Powder bulk and flow properties were assessed by bulk densities and shear cell measurements. The aerosol performance was studied by laser diffraction and supported by a twin-stage impinger. High degrees of coating coverage were achieved after mechanofusion, as measured by X-ray photoelectron spectroscopy. Concomitant significant increases occurred in powder bulk densities and in aerosol performance after coating. The apparent optimum performance corresponded with using 2% w/w magnesium stearate. In contrast, traditional blending resulted in no significant changes in either bulk or aerosolization behaviour compared to the untreated sample. It is believed that conventional low-shear blending provides insufficient energy levels to expose host micronized particle surfaces from agglomerates and to distribute guest coating material effectively for coating. A simple ultra-high-shear mechanical dry powder coating step was shown as highly effective in producing ultra-thin coatings on micronized powders and to substantially improve the powder aerosolization efficiency.

  19. The Natural History of Pneumonic Tularemia in Female Fischer 344 Rats after Inhalational Exposure to Aerosolized Francisella tularensis Subspecies tularensis Strain SCHU S4.

    Science.gov (United States)

    Hutt, Julie A; Lovchik, Julie A; Dekonenko, Alexander; Hahn, Andrew C; Wu, Terry H

    2017-02-01

    The inbred Fischer 344 rat is being evaluated for testing novel vaccines and therapeutics against pneumonic tularemia. Although primary pneumonic tularemia in humans typically occurs by inhalation of aerosolized bacteria, the rat model has relied on intratracheal inoculation of organisms because of safety and equipment issues. We now report the natural history of pneumonic tularemia in female Fischer 344 rats after nose-only inhalational exposure to lethal doses of aerosolized Francisella tularensis subspecies tularensis, strain SCHU S4. Our results are consistent with initial uptake of aerosolized SCHU S4 from the nasal cavity, lungs, and possibly the gastrointestinal tract. Bacteremia with hematogenous dissemination was first detected 2 days after exposure. Shortly thereafter, the infected rats exhibited fever, tachypnea, and hypertension that persisted for 24 to 36 hours and then rapidly decreased as animals succumbed to infection between days 5 and 8 after exposure. Tachycardia was observed briefly, but only after the core body temperature and blood pressure began to decrease as the animals were near death. Initial neutrophilic and histiocytic inflammation in affected tissues became progressively more fibrinous and necrotizing over time. At death, as many as 10 10 colony-forming units were found in the lungs, spleen, and liver. Death was attributed to sepsis and disseminated intravascular coagulation. Overall, the pathogenesis of pneumonic tularemia in the female F344 rat model appears to replicate the disease in humans. Copyright © 2017 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  20. Granulometric determinations and inhalation dose assessment for atmospheric aerosol contaminated by {sup 137}Cs; Determinazioni granulometriche e valutazioni di dose da inalazione per aerosol atmosferico contaminato da {sup 137}CS

    Energy Technology Data Exchange (ETDEWEB)

    Castellani, C.M.; Luciani, A. [ENEA, Centro Ricerche `E. Clementel`, Bologna (Italy). Dip. Ambiente; Oliviero, L.; Donato, R. [ENEA, Centro Ricerche Saluggia, Vercelli (Italy). Dip. Ambiente

    1996-07-01

    During the redevelopment of Brescia freight-yard a measurement campaign of atmospheric aerosol was carried out: in fact a {sup 137}Cs ground contamination, caused by the permanence of wagons carrying iron materials contaminated by this radionuclide, had been found out. During the redevelopment phases of excavation and can filling the workers were exposed to the danger of radioactive aerosol inhalation. The aim of the measurement campaign was to test the aerosol sampling and granulometric analysis methodologies with their sensitivity related to the inhalation dose assessments. The results of both aerosuspended mass and activity, evaluated by means of a portable cascade impactor, are presented. The granulometries have been interpolated with a log normal distribution using an iterative routine minimizing the square deviation between the calculated and experimental data. The results related to the dose assessments are also presented. These evaluations have been carried out using both the granulometric information obtained and the more recent models (ICRP 66) both the total concentration data and the dose coefficients referring to the standard conditions of ICRP 68 and of the Italian law (D.Lgs. 230/95). Furthermore the significance and the reliability of the dose assessments referring to the different methodologies are discussed, also in relation to the possibility of using this sampling methodologies for other radionuclides and different exposure conditions.

  1. A Comparison of the OSHA Modified NIOSH Physical and Chemical Analytical Method (P and CAM) 304 and the Dust Trak Photometric Aerosol Sampler for 0-Chlorobenzylidine Malonitrile

    Science.gov (United States)

    2013-04-02

    Paper is ripped up and placed inside the coffee can, followed by the opening of CS capsules where granules of the CS are dispersed into the paper... coffee can was placed on top of the hot plate. Paper is ripped up and placed inside the coffee can to assist in the burning of the capsules , capsules ...be re-aerosolized as dried aerosol- particulates. Additionally, the outer casings of the CS capsules and paper were often added to the coffee can to

  2. Direct-reading inhalable dust monitoring--an assessment of current measurement methods.

    Science.gov (United States)

    Thorpe, Andrew; Walsh, Peter T

    2013-08-01

    Direct-reading dust monitors designed specifically to measure the inhalable fraction of airborne dust are not widely available. Current practice therefore often involves comparing the response of photometer-type dust monitors with the concentration measured with a reference gravimetric inhalable sampler, which is used to adjust the dust monitor measurement. However, changes in airborne particle size can result in significant errors in the estimation of inhalable concentration by this method. The main aim of this study was to assess how these dust monitors behave when challenged with airborne dust containing particles in the inhalable size range and also to investigate alternative dust monitors whose response might not be as prone to variations in particle size or that could be adapted to measure inhalable dust concentration. Several photometer-type dust monitors and a Respicon TM, tapered element oscillating microbalance (TEOM) personal dust monitor (PDM) 3600, TEOM 1400, and Dustrak DRX were assessed for the measurement of airborne inhalable dust during laboratory and field trials. The PDM was modified to allow it to sample and measure larger particles in the inhalable size range. During the laboratory tests, the dust monitors and reference gravimetric samplers were challenged inside a large dust tunnel with aerosols of industrial dusts known to present an inhalable hazard and aluminium oxide powders with a range of discrete particle sizes. A constant concentration of each dust type was generated and peak concentrations of larger particles were periodically introduced to investigate the effects of sudden changes in particle size on monitor calibration. The PDM, Respicon, and DataRam photometer were also assessed during field trials at a bakery, joinery, and a grain mill. Laboratory results showed that the Respicon, modified PDM, and TEOM 1400 observed good linearity for all types of dust when compared with measurements made with a reference IOM sampler; the

  3. Biological alterations resulting from chronic lung irradiation. II. Connective tissue alterations following inhalation of 144Ce fused clay aerosol in beagle dogs

    International Nuclear Information System (INIS)

    Pickrell, J.A.; Harris, D.V.; Pfleger, R.C.; Benjamin, S.A.; Belasich, J.J.; Jones, R.K.; McClellan, R.O.

    1975-01-01

    Beagle dogs were exposed by inhalation to an aerosol of 144 Ce clay to quantitate the relationship between pulmonary radiation dose and induced fibrosis. Collagen, elastin, glucosamine, and the ratios of elastin/collagen, hydroxyproline/hydroxylysine, and hydroxyproline/proline were determined to indicate changes in connective tissue constituents. Total lung collagen was partitioned into native collagen, soluble collagen, and ultrafilterable hydroxyproline peptides. Increased total lung collagen correlated best with increasing cumulative radiation dose and increasing time after inhalation exposure. The increase in total lung collagen was not seen until more than 4 mo after exposure and a cumulative dose of about 40,000 rad. Soluble collagen and low molecular weight hydroxyproline peptide quantities both increased at 2 mo after exposure and cumulative doses of 20,000 to 27,000 rad. A variable elastin response apparently was not related to either increasing time or increasing radiation dose after exposure. These results indicate that collagen accumulation is an important factor in pulmonary fibrosis. Although collagen synthesis and breakdown were both activated at a relatively early time after inhalation, a significant increase in native collagen (scarring) occurred only when the metabolic balance was altered by protracted time or irradiation after exposure. The interrelationships observed in this study provide insight into the mechanism of fibrosis induced by chronic pulmonary injury. (U.S.)

  4. In vivo evaluation of the potential neurotoxicity of aerosols released from mechanical stress of nano-TiO2 additived paints in mice chronically exposed by inhalation

    Science.gov (United States)

    Manixay, S.; Delaby, S.; Gaie-Levrel, F.; Wiart, M.; Motzkus, C.; Bencsik, A.

    2017-06-01

    Engineered Nanomaterials (ENM) provide technical and specific benefits due to their physical-chemical properties at the nanometer scale. For instance, many ENM are used to improve products in the building industry. Nanoscaled titanium dioxide (TiO2) is one of the most used ENM in this industry. Incorporated in different matrix, cement, glass, paints… TiO2 nanoparticles (NPs) provide the final product with anti-UV, air purification and self-cleaning properties, thanks to their photocatalytic activity. However, ageing processes of such products, as photocatalytic paints, during a mechanical stress have been shown to release TiO2 NPs from this matrix associated with sanding dust. Thus, workers who sand painted walls could be exposed to TiO2 NPs through inhalation. As inhalation may lead to a translocation of particulate matter to the brain via olfactory or trigeminal nerves, there is an urgent need for evaluating a potential neurotoxicity. In order to provide new knowledge on this topic, we developed a dedicated experimental set-up using a rodent model exposed via inhalation. The aerosol released from a mechanical stress of photocatalytic paints containing TiO2 NPs was characterized and coupled to an exposition chamber containing group of mice free to move and chronically exposed (2 hours per day for 5 days a week during 8 weeks).

  5. In vivo evaluation of the potential neurotoxicity of aerosols released from mechanical stress of nano-TiO2 additived paints in mice chronically exposed by inhalation

    International Nuclear Information System (INIS)

    Manixay, S; Bencsik, A; Delaby, S; Gaie-Levrel, F; Wiart, M; Motzkus, C

    2017-01-01

    Engineered Nanomaterials (ENM) provide technical and specific benefits due to their physical-chemical properties at the nanometer scale. For instance, many ENM are used to improve products in the building industry. Nanoscaled titanium dioxide (TiO 2 ) is one of the most used ENM in this industry. Incorporated in different matrix, cement, glass, paints… TiO 2 nanoparticles (NPs) provide the final product with anti-UV, air purification and self-cleaning properties, thanks to their photocatalytic activity. However, ageing processes of such products, as photocatalytic paints, during a mechanical stress have been shown to release TiO 2 NPs from this matrix associated with sanding dust. Thus, workers who sand painted walls could be exposed to TiO 2 NPs through inhalation. As inhalation may lead to a translocation of particulate matter to the brain via olfactory or trigeminal nerves, there is an urgent need for evaluating a potential neurotoxicity. In order to provide new knowledge on this topic, we developed a dedicated experimental set-up using a rodent model exposed via inhalation. The aerosol released from a mechanical stress of photocatalytic paints containing TiO 2 NPs was characterized and coupled to an exposition chamber containing group of mice free to move and chronically exposed (2 hours per day for 5 days a week during 8 weeks). (paper)

  6. Co-milled API-lactose systems for inhalation therapy: impact of magnesium stearate on physico-chemical stability and aerosolization performance.

    Science.gov (United States)

    Lau, Michael; Young, Paul M; Traini, Daniela

    2017-06-01

    Particle micronization for inhalation can impart surface disorder (amorphism) of crystalline structures. This can lead to stability issues upon storage at elevated humidity from recrystallization of the amorphous state, which can subsequently affect the aerosol performance of the dry powder formulation. The aim of this study was to investigate the impact of an additive, magnesium stearate (MGST), on the stability and aerosol performance of co-milled active pharmaceutical ingredient (API) with lactose. Blends of API-lactose with/without MGST were prepared and co-milled by the jet-mill apparatus. Samples were stored at 50% relative humidity (RH) and 75% RH for 1, 5, and 15 d. Analysis of changes in particle size, agglomerate structure/strength, moisture sorption, and aerosol performance were analyzed by laser diffraction, scanning electron microscopy (SEM), dynamic vapor sorption (DVS), and in-vitro aerodynamic size assessment by impaction. Co-milled formulation with MGST (5% w/w) led to a reduction in agglomerate size and strength after storage at elevated humidity compared with co-milled formulation without MGST, as observed from SEM and laser diffraction. Hysteresis in the sorption/desorption isotherm was observed in the co-milled sample without MGST, which was likely due to the recrystallization of the amorphous regions of micronized lactose. Deterioration in aerosol performance after storage at elevated humidity was greater for the co-milled samples without MGST, compared with co-milled with MGST. MGST has been shown to have a significant impact on co-milled dry powder stability after storage at elevated humidity in terms of physico-chemical properties and aerosol performance.

  7. Design, physicochemical characterization, and optimization of organic solution advanced spray-dried inhalable dipalmitoylphosphatidylcholine (DPPC and dipalmitoylphosphatidylethanolamine poly(ethylene glycol (DPPE-PEG microparticles and nanoparticles for targeted respiratory nanomedicine delivery as dry powder inhalation aerosols

    Directory of Open Access Journals (Sweden)

    Meenach SA

    2013-01-01

    total-reflectance Fourier-transform infrared (ATR-FTIR spectroscopy and confocal Raman microscopy (CRM, and chemical imaging confirmed the chemical homogeneity of the particles. The dry powder aerosol dispersion properties were evaluated using the Next Generation Impactor™ (NGI™ coupled with the HandiHaler® dry powder inhaler device, where the mass median aerodynamic diameter from 2.6 to 4.3 μm with excellent aerosol dispersion performance, as exemplified by high values of emitted dose, fine particle fraction, and respirable fraction. Overall, it was determined that the pump rates defined in the spray-drying process had a significant effect on the solid-state particle properties and that a higher pump rate produced the most optimal system. Advanced dry powder inhalers of inhalable lipopolymers for targeted dry powder inhalation delivery were successfully achieved.Keywords: biocompatible biodegradable lipopolymers, lung surfactant, pulmonary delivery, self-assemblies, solid-state, lipospheres

  8. Use of air sampling data from uranium mills to estimate respiratory tract deposition rates for inhaled yellowcake

    International Nuclear Information System (INIS)

    Eidson, A.F.

    1982-01-01

    Uranium aerosols generated during normal yellowcake packaging operations were sampled at four uranium mills. Samplers located in the packaging area were operated before, during and after drums of dried yellowcake were filled and sealed. Mediar aerosol concentrations ranged from 0.04 μg U/l to 0.34 μg U/1 during the routine packaging operations at the four mills. The aerosols were heterogeneous and included a broad range of particle sizes. Both the concentrations and particle size distributions varied with time. Aerosol characteristics could often be related to individual packaging steps. Sampling of yellowcake by hand from a filled open drum to measure the yellowcake moisture content need not pose a unique hazard to the operator. The combined results show that appreciable amounts of airborne uranium would be expected to deposit in the nasopharyngeal compartment of the respiratory tract if inhaled by a worker not wearing respiratory protection

  9. Workplace aerosol mass concentration measurement using optical particle counters.

    Science.gov (United States)

    Görner, Peter; Simon, Xavier; Bémer, Denis; Lidén, Göran

    2012-02-01

    Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM® 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO®) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions

  10. Inhalation exposures during operations in spent fuel bays

    International Nuclear Information System (INIS)

    Dua, S.K.; Maniyan, C.G.; Kotrappa, P.

    1987-01-01

    Radioactive aerosols are generated during operations (transfer, cutting, storage and shipment of fuel) in spent fuel bays. A study has been carried out on the airborne concentration, size distribution and solubility of the aerosol, to evaluate the inhalation exposure of the workers. Personal air samplers were used for the measurement of concentration of airborne radioactivity and Andersen impactor for particle size distribution. Some of the collected sampels were followed for their solubility in lung serum simulant for a period of about 200 days. The observed concentrations of the aerosols and their activity median aerodynamic diameters (AMAD) were 418 ± 443 Bq m -3 (βγ), 1.28 ± 1.478 Bq m -3 (∞) and 6.79 ± 0.4μm respectively. Analysis of the samples revealed the presence of 239 Pu, U, 90 Sr and 137 Cs. The clearance half-life of the aerosols was the same (155 days) for all the isotopes (U, 239 Pu, 90 Sr; 137 Cs). Calculation of effective dose equivalent for the clearance half-life and for 6.79 μm AMAD aerosols was carried out using the method recommended in ICRP-30. Annual effective dose equivalent of the workers, if no respirators were worn, worked out to be 3.2 mSv (320 mrem), the contribution from alpha emitters being about 63 per cent of the total. (author). 5 refs., 2 tables

  11. Exposure of F344 rats to aerosols of 239PuO2 and chronically inhaled cigarette smoke

    International Nuclear Information System (INIS)

    Finch, G.L.; Nikula, K.J.; Barr, E.B.; Bechtold, W.E.; Chen, B.T.; Griffith, W.C.; Hobbs, C.H.; Hoover, M.D.; Mauderly, J.L.

    1994-01-01

    Nuclear workers may be accidently exposed to radioactive materials such as 239 PuO 2 by inhalation, and thus have increased risk for lung cancer compared to the general population. Of additional concern is the possibility that interactions between radionuclides and other carcinogens may increase the risk of cancer induction. An important and common lung carcinogen is cigarette smoke. This study is being conducted to better determine the combined effects of inhaled 239 PuO 2 and cigarette smoke on the induction of lung cancer in rats

  12. The use of combined single photon emission computed tomography and X-ray computed tomography to assess the fate of inhaled aerosol.

    Science.gov (United States)

    Fleming, John; Conway, Joy; Majoral, Caroline; Tossici-Bolt, Livia; Katz, Ira; Caillibotte, Georges; Perchet, Diane; Pichelin, Marine; Muellinger, Bernhard; Martonen, Ted; Kroneberg, Philipp; Apiou-Sbirlea, Gabriela

    2011-02-01

    Gamma camera imaging is widely used to assess pulmonary aerosol deposition. Conventional planar imaging provides limited information on its regional distribution. In this study, single photon emission computed tomography (SPECT) was used to describe deposition in three dimensions (3D) and combined with X-ray computed tomography (CT) to relate this to lung anatomy. Its performance was compared to planar imaging. Ten SPECT/CT studies were performed on five healthy subjects following carefully controlled inhalation of radioaerosol from a nebulizer, using a variety of inhalation regimes. The 3D spatial distribution was assessed using a central-to-peripheral ratio (C/P) normalized to lung volume and for the right lung was compared to planar C/P analysis. The deposition by airway generation was calculated for each lung and the conducting airways deposition fraction compared to 24-h clearance. The 3D normalized C/P ratio correlated more closely with 24-h clearance than the 2D ratio for the right lung [coefficient of variation (COV), 9% compared to 15% p computer analysis is a useful approach for applications requiring regional information on deposition.

  13. A radon progeny sampler for the determination of effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Solomon, S.B. [Australian Radiation Laboratory, Victoria (Australia)

    1997-12-01

    The design and simulated performance is described of a two-stage sampler (HE-Sampler) for {sup 222}Rn progeny. This HE-Sampler has a collection efficiency optimised to match the particle size dependency of the radon progeny dose conversion factor (DCF), derived from the latest Respiratory Tract Model of the International Commission on Radiological Protection, as implemented in the computer code RADEP. The He-Sampler comprises a wire screen pre-separator, matched to the nasal deposition, and a wire screen collector, matched to the respiratory tract collection. This HE-Sampler allows for the estimation of the radiation dose from the inhalation of {sup 222}Rn progeny, derived from two concurrent alpha particle activity measurements, one on the HE-Sampler screen collector and one on a reference filter sample. As a first approximation, the DCF is proportional to the collected fraction. The HE-Sampler response was simulated for a range of radon progeny size distributions to determine the error in the estimated DCF values. The simulation results show that the HE-Sampler is relatively insensitive to variations in sampling rate and in the screen parameters, particularly for environmental exposure. (Author).

  14. Sampling Indoor Aerosols on the International Space Station

    Science.gov (United States)

    Meyer, Marit E.

    2016-01-01

    In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

  15. Quantification and risks associated with bacterial aerosols near domestic greywater-treatment systems

    Energy Technology Data Exchange (ETDEWEB)

    Benami, Maya; Busgang, Allison; Gillor, Osnat; Gross, Amit, E-mail: amgross@exchange.bgu.ac.il

    2016-08-15

    Greywater (GW) reuse can alleviate water stress by lowering freshwater consumption. However, GW contains pathogens that may compromise public health. During the GW-treatment process, bioaerosols can be produced and may be hazardous to human health if inhaled, ingested, or come in contact with skin. Using air-particle monitoring, BioSampler®, and settle plates we sampled bioaerosols emitted from recirculating vertical flow constructed wetlands (RVFCW) – a domestic GW-treatment system. An array of pathogens and indicators were monitored using settle plates and by culturing the BioSampler® liquid. Further enumeration of viable pathogens in the BioSampler® liquid utilized a newer method combining the benefits of enrichment with molecular detection (MPN-qPCR). Additionally, quantitative microbial risk assessment (QMRA) was applied to assess risks of infection from a representative skin pathogen, Staphylococcus aureus. According to the settle-plate technique, low amounts (0–9.7 × 10{sup 4} CFU m{sup −2} h{sup −1}) of heterotrophic bacteria, Staphylococcus spp., Pseudomonas spp., Klebsiella pneumoniae, Enterococcus spp., and Escherichia coli were found to aerosolize up to 1 m away from the GW systems. At the 5 m distance amounts of these bacteria were not statistically different (p > 0.05) from background concentrations tested over 50 m away from the systems. Using the BioSampler®, no bacteria were detected before enrichment of the GW-aerosols. However, after enrichment, using an MPN-qPCR technique, viable indicators and pathogens were occasionally detected. Consequently, the QMRA results were below the critical disability-adjusted life year (DALY) safety limits, a measure of overall disease burden, for S. aureus under the tested exposure scenarios. Our study suggests that health risks from aerosolizing pathogens near RVFCW GW-treatment systems are likely low. This study also emphasizes the growing need for standardization of bioaerosol-evaluation techniques

  16. Quantification and risks associated with bacterial aerosols near domestic greywater-treatment systems

    International Nuclear Information System (INIS)

    Benami, Maya; Busgang, Allison; Gillor, Osnat; Gross, Amit

    2016-01-01

    Greywater (GW) reuse can alleviate water stress by lowering freshwater consumption. However, GW contains pathogens that may compromise public health. During the GW-treatment process, bioaerosols can be produced and may be hazardous to human health if inhaled, ingested, or come in contact with skin. Using air-particle monitoring, BioSampler®, and settle plates we sampled bioaerosols emitted from recirculating vertical flow constructed wetlands (RVFCW) – a domestic GW-treatment system. An array of pathogens and indicators were monitored using settle plates and by culturing the BioSampler® liquid. Further enumeration of viable pathogens in the BioSampler® liquid utilized a newer method combining the benefits of enrichment with molecular detection (MPN-qPCR). Additionally, quantitative microbial risk assessment (QMRA) was applied to assess risks of infection from a representative skin pathogen, Staphylococcus aureus. According to the settle-plate technique, low amounts (0–9.7 × 10"4 CFU m"−"2 h"−"1) of heterotrophic bacteria, Staphylococcus spp., Pseudomonas spp., Klebsiella pneumoniae, Enterococcus spp., and Escherichia coli were found to aerosolize up to 1 m away from the GW systems. At the 5 m distance amounts of these bacteria were not statistically different (p > 0.05) from background concentrations tested over 50 m away from the systems. Using the BioSampler®, no bacteria were detected before enrichment of the GW-aerosols. However, after enrichment, using an MPN-qPCR technique, viable indicators and pathogens were occasionally detected. Consequently, the QMRA results were below the critical disability-adjusted life year (DALY) safety limits, a measure of overall disease burden, for S. aureus under the tested exposure scenarios. Our study suggests that health risks from aerosolizing pathogens near RVFCW GW-treatment systems are likely low. This study also emphasizes the growing need for standardization of bioaerosol-evaluation techniques to provide

  17. The clearance of Pu and Am from the respiratory system of rodents after the inhalation of oxide aerosols of these actinides either alone or in combination with other metals

    International Nuclear Information System (INIS)

    Stather, J.W.; James, A.C.; Brightwell, J.; Rodwell, P.

    1979-01-01

    In this series of studies in rodents the lung clearance and tissue distribution of both plutonium and americium have been measured following their inhalation as mixed actinide oxides either alone or in combination with other metals. The aerosols used were materials to which workers in the nuclear industry may be occupationally exposed or which could be generated in the event of an accident in a reactor core or fuel fabrication plant. The studies showed that, at least for some PuO 2 aerosols, the lung model currently being used by ICRP for estimating tissue doses from inhaled actinides may overestimate, by about a factor of ten, the amount of plutonium translocated to the blood. The presence of oxides of other metals can, however, appreciably influence the clearance of plutonium from the lung. While in some mixtures plutonium dioxide behaves as an insoluble (Class Y) compound and in others as a soluble (Class W) compound, it may also have transportability characteristics between these two extremes. Americium-241 behaves as a soluble (Class W) compound when inhaled as the oxide. However, if it is present in trace quantities in mixed-oxide aerosols its behaviour depends upon that of the materials present in greatest mass. (author)

  18. Broncodilatadores en la crisis asmática: ¿Aerosol o nebulización? Bronchodilators in acute asthma: metered dose inhalers or wet nebulizations?

    Directory of Open Access Journals (Sweden)

    Dora M. Lombardi

    2006-12-01

    Full Text Available El número de consultas por asma aguda en el Hospital María Ferrer ha aumentado de 3300 consultas anuales en 1980 a 15364 en 2002. Los broncodilatadores de acción corta (salbutamol-ipratropio en nebulizaciones, procedimiento que consume tiempo y recursos humanos, eran el tratamiento inicial en 2002. Para tratar de mejorar el cumplimiento del tratamiento frente al aumento de la demanda, se reemplazaron las nebulizaciones por aerosoles dosificadores. El objetivo de este estudio es evaluar el impacto de este cambio. Comparamos 90 pacientes con crisis asmática tratados con aerosoles en diciembre del 2003 con igual número tratados con nebulizaciones en diciembre del 2002 pareados por sexo, edad, altura, VEF1 teórico y de ingreso. Con aerosoles se observó una reducción significativa del tiempo de permanencia en el Departamento de Emergencia (mediana 3 h (2-4.75 versus 4 h (1-6 p=0.01 y un número mayor de altas en las primeras 2 horas (48% vs. 31% p=0.03. Los pacientes tratados con aerosol recibieron el 87% de las dosis prescriptas, mientras que el otro grupo recibió sólo el 38%. El VEF1 mostró una tendencia a ser mayor al egreso en el grupo que recibió aerosoles, pero la diferencia no fue estadísticamente significativa (78% ± 17% vs. 73% ± 17% p=0.09. El porcentaje de alta final fue similar en los dos grupos (96% vs. 93%. El tratamiento con aerosoles produjo una mejoría más rápida y mejor cumplimiento de las normas de tratamiento indicadas.The number of patients attending our Emergency Department (ED with acute asthma has increased from 3300 patient/year in 1980 to 15364 in 2003. Short acting bronchodilators (albuterol/ipratropium administered in wet nebulizations, a resource consuming procedure, were our main initial treatment in 2002. To improve treatment goals, we switched the method of bronchodilator delivery to metered dose inhalers (MDI in 2003. The purpose of this study is to evaluate the impact of this change in the

  19. Inhaler devices - from theory to practice

    DEFF Research Database (Denmark)

    Sanchis, Joaquin; Corrigan, Chris; Levy, Mark L

    2013-01-01

    This brief overview of the factors determining lung deposition of aerosols provides background information required by health care providers when instructing patients to use their prescribed inhalers. We discuss differences in the optimal inhalation manoeuvres for each type of aerosol generator a...

  20. [Therapeutic effect of the association between pulmonary ventilation and aerosol--inhalation with sulphureous mineral water in the chronic bronchopneumopathies].

    Science.gov (United States)

    Lopalco, M; Proia, A R; Fraioli, A; Serio, A; Cammarella, I; Petraccia, L; Grassi, M

    2004-04-01

    Our research evaluates the efficacy of the inalation therapy by mineral sulphureous water in patients suffering from cronic bronchopneumopathy. From August to October 2002, two groups of patients, randomly selected, suffering from cronic bronchopneumonopathy, were studied at spa center "Pompeo" in Ferentino (FR). Every patient was treated daily during a cycle of twelve days. The first group was treated by pneumonic mechanical ventilation associated to sulphureous water aerosolinalation, the second by mechanical pulmonary ventilation associated to sulphureous water aerosol-inalation medicated with flunisolide. Every patient carried out spirometry, before and after treatment, and the measurement of FEV1 was considered a good parameter to evaluate the respiratory function. All patients reported an improvement in symptoms as dyspnea and cough. Results obtained show a significant functional improvement of respiratory function in both groups, evaluated by FEV1. Equal efficacy treating the patients by medicated and not medicated treatments stress the therapeutic role of mineral sulphureous waters in chronic bronchopneumopathies. Our research points out the usefullness of pneumonic ventilation associated with sulphureous water aerosol-inalation in patients suffering from chronic bronchopneumopathies.

  1. Short term inhalation toxicity of a liquid aerosol of glutaraldehyde-coated CdS/Cd(OH)2 core shell quantum dots in rats.

    Science.gov (United States)

    Ma-Hock, L; Farias, P M A; Hofmann, T; Andrade, A C D S; Silva, J N; Arnaud, T M S; Wohlleben, W; Strauss, V; Treumann, S; Chaves, C R; Gröters, S; Landsiedel, R; van Ravenzwaay, B

    2014-02-10

    Quantum dots exhibit extraordinary optical and mechanical properties, and the number of their applications is increasing. In order to investigate a possible effect of coating on the inhalation toxicity of previously tested non-coated CdS/Cd(OH)2 quantum dots and translocation of these very small particles from the lungs, rats were exposed to coated quantum dots or CdCl2 aerosol (since Cd(2+) was present as impurity), 6h/d for 5 consecutive days. Cd content was determined in organs and excreta after the end of exposure and three weeks thereafter. Toxicity was determined by examination of broncho-alveolar lavage fluid and microscopic evaluation of the entire respiratory tract. There was no evidence for translocation of particles from the respiratory tract. Evidence of a minimal inflammatory process was observed by examination of broncho-alveolar lavage fluid. Microscopically, minimal to mild epithelial alteration was seen in the larynx. The effects observed with coated quantum dots, non-coated quantum dots and CdCl2 were comparable, indicating that quantum dots elicited no significant effects beyond the toxicity of the Cd(2+) ion itself. Compared to other compounds with larger particle size tested at similarly low concentrations, quantum dots caused much less pronounced toxicological effects. Therefore, the present data show that small particle sizes with corresponding high surfaces are not the only factor triggering the toxic response or translocation. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. Measuring Aerosols Generated Inside Armoured Vehicles Perforated by Depleted Uranium Ammunition

    International Nuclear Information System (INIS)

    Parkhurst, MaryAnn

    2003-01-01

    In response to questions raised after the Gulf War about the health significance of exposure to depleted uranium (DU), the U.S. Department of Defense initiated a study designed to provide an improved scientific basis for assessment of possible health effects of soldiers in vehicles struck by these munitions. As part of this study, a series of DU penetrators were fired at an Abrams tank and a Bradley fighting vehicle, and the aerosols generated by vehicle perforation were collected and characterized. A robust sampling system was designed to collect aerosols in this difficult environment and to monitor continuously the sampler flow rates. Interior aerosols collected were analyzed for uranium concentration and particle size distribution as a function of time. They were also analyzed for uranium oxide phases, particle morphology, and dissolution in vitro. These data will provide input for future prospective and retrospective dose and health risk assessments of inhaled or ingested DU aerosols. This paper briefly discusses the target vehicles, firing trajectories, aerosol samplers and instrumentation control systems, and the types of analyses conducted on the samples

  3. Indoor Sampler Siting

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Michael D.; Lorenzetti, David M.

    2009-03-01

    Contaminant releases in or near a building can lead to significant human exposures unless prompt response is taken. U.S. Federal and local agencies are implementing programs to place air-monitoring samplers in buildings to quickly detect biological agents. We describe a probabilistic algorithm for siting samplers in order to detect accidental or intentional releases of biological material. The algorithm maximizes the probability of detecting a release from among a suite of realistic scenarios. The scenarios may differ in any unknown, for example the release size or location, weather, mode of building operation, etc. The algorithm also can optimize sampler placement in the face of modeling uncertainties, for example the airflow leakage characteristics of the building, and the detection capabilities of the samplers. In an illustrative example, we apply the algorithm to a hypothetical 24-room commercial building, finding optimal networks for a variety of assumed sampler types and performance characteristics. We also discuss extensions of this work for detecting ambient pollutants in buildings, and for understanding building-wide airflow, pollutant dispersion, and exposures.

  4. Inhaled Steroids

    Science.gov (United States)

    ... considerations when your dosage changes. What about side effects and inhaled steroids? The most common side effects with inhaled steroids ... inhaled steroid has much less potential for side effects than steroid pills or syrups. There have been concerns regarding ...

  5. Inhalant Abuse

    Science.gov (United States)

    ... is when you pour the product into a bag, hold it over your mouth and nose, and inhale. How is inhalant abuse diagnosed? If you think your child is abusing inhalants, talk to them. Be honest and open. Tell them ...

  6. Inhalation exposures during operations in spent fuel bays

    International Nuclear Information System (INIS)

    Dua, S.K.; Maniyan, C.G.; Kotrappa, P.

    1987-01-01

    Radioactive aerosols are generated during operations (transfer, cutting, storage and shipment of fuel) in spent fuel bays. A study has been carried out on the airborne concentration, size distribution and dissolution rate of aerosols to evaluate the inhalation exposure of the workers. Personal air samplers were used for the measurement of concentration of airborne radioactivity and an Andersen impactor for the particle size distribution. The dissolution rates of some of the collected samples in lung serum simulant were followed for a period of about 200 days. Analysis of the samples revealed the presence of 239 Pu, U, 90 Sr and 137 Cs. For all the radionuclides measured ( 239 Pu, U, 90 Sr, 137 Cs) 40% of the activity dissolved rapidly (half-time 1.2d), the remainder with a half-time of 155 d. Calculation of effective dose equivalent for this dissolution half-time and for 6.8μm AMAD aerosols was carried out using the method recommended in ICRP 30 and reported in literature. The annual effective dose equivalent of the workers, if no respirators are worn, worked out to be 8.9 mSv (890 mrem), the contribution from alpha emitters being about 91% of the total. (author)

  7. Repiratory carcinogenesis in rats after inhalation of radioactive aerosols of actinides and lanthanides in various physicochemical forms

    International Nuclear Information System (INIS)

    LaFuma, J.; Nenot, J.C.; Morin, M.; Masse, R.; Metivier, H.; Nobile, D.; Skupinski, W.

    1974-01-01

    To study the role of the distribution of local tissue irradiation on the toxicity of alpha emitters, groups of 50 to 165 rats were exposed to aerosols of 244 Cm(NO 3 ) 3 , 241 Am(NO 3 ) 3 , 238 Pu(NO 3 ) 4 , 235 Pu(NO 3 ) 4 , 239 PuO 2 , and 241 AmO 2 and observed for effects. Curium-244 was most evenly distributed in the lung and most effective in reduction of survival time followed in descending order by 238 Pu(NO 3 ) 4 , 241 Am(NO 3 ) 3 , 241 AmO 2 , 239 Pu(NO 3 ) 4 , and 239 PuO 2 , which was more heterogeneously distributed in the lung as particulate. The toxicity had 2 results: shortening of life span and cancer induction (about 50 percent bronchogenic carcinoma and 40 percent bronchiolo-alveolar carcinomas). There appeared to be no correlation between survival time and cancer induction or localization of the element in the lung and the starting point of the tumors. This histologic type of cancer was independent of the nature of the element. Toxicity and cancer induction appeared to depend on the homogenicity of radiation dose with the more evenly distributed dose being most effective

  8. Size selective isocyanate aerosols personal air sampling using porous plastic foams

    International Nuclear Information System (INIS)

    Cong Khanh Huynh; Trinh Vu Duc

    2009-01-01

    As part of a European project (SMT4-CT96-2137), various European institutions specialized in occupational hygiene (BGIA, HSL, IOM, INRS, IST, Ambiente e Lavoro) have established a program of scientific collaboration to develop one or more prototypes of European personal samplers for the collection of simultaneous three dust fractions: inhalable, thoracic and respirable. These samplers based on existing sampling heads (IOM, GSP and cassettes) use Polyurethane Plastic Foam (PUF) according to their porosity to support sampling and separator size of the particles. In this study, the authors present an original application of size selective personal air sampling using chemical impregnated PUF to perform isocyanate aerosols capturing and derivatizing in industrial spray-painting shops.

  9. Indigenous high volume air sampler

    International Nuclear Information System (INIS)

    Kotrappa, P.; Setty, N.P.N.; Raghunath, B.; Sivasubrahmanyam, P.S.

    1978-01-01

    A high volume air sampler for use in assessing concentrations of low levels of air borne particulates has been fabricated. The sampler will be of use in radioactive installations, conventional industries and environmental pollution analysis. It is comparable in performance with the imported Staplex air samplers. A turbine and motor system similar to the one found in conventional vacuum cleaners is used in its design. The sampler units can be produced in large numbers. (M.G.B.)

  10. Late effects following inhalation of mixed oxide (U,PuO{sub 2}) mox aerosol in the rat; Effets tardifs de l'inhalation d'aerosols de Mox 2,5% ou 7,1% Pu chez le rat

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, N.; Van Der Meeren, A.; Fritsch, P.; Maximilien, R

    2008-07-01

    Exposure to alpha-emitting particles is a potential long-term health risk to workers in nuclear fuel fabrication plants. Mixed Oxide (MOX: U,PuO{sub 2}) fuels containing low percentages of plutonium obtained from spent nuclear fuels are increasingly employed and in the case of accidental contamination by inhalation or wounds may result in the development of late-occurring pathologies such as lung cancer. However the long term risks particularly with regard to lung cancer are to date unclear. In the case of MOX the risk may indeed be different from that assigned to the individual components, plutonium and uranium. Several factors are influential (i) the dissolution of Pu depends on the physico-chemical properties, for example risk of lung cancer is increased 10 fold after Pu(NO{sub 3}){sub 2} as compared with PuO{sub 2}. (ii) The solubility of Pu is variable whether delivered as PuO{sub 2} or contained within MOX. (iii) The risk of cancer appears to increase with spatial homogeneity of the lung alpha dose. The objective of this study was to investigate the long term effects in rat lungs following MOX aerosol inhalation of similar particle size containing 2.5 or 7.1% Pu. Conscious rats were exposed to MOX aerosols using a 'nose-only' system and kept for their entire life (2-3 years). Different Initial Lung Deposits (ILDs) were obtained using different concentrations of the MOX suspension. Lung total alpha activity was determined in vivo at intervals over the study period by external counting as well as at autopsy in order to estimate the total lung dose. Anatomo-pathological and immunohistochemical analyses were performed on fixed lung tissue after euthanasia. The frequencies of lung pathologies and tumours were determined on lung sections at several different levels. In addition, autoradiography of lung sections was performed in order to assess the spatial localisation of a activity. Inhalation of MOX at ILD ranging from 1-20 kBq resulted in lung

  11. Microbial aerosol generation during laboratory accidents and subsequent risk assessment.

    Science.gov (United States)

    Bennett, A; Parks, S

    2006-04-01

    To quantify microbial aerosols generated by a series of laboratory accidents and to use these data in risk assessment. A series of laboratory accident scenarios have been devised and the microbial aerosol generated by them has been measured using a range of microbial air samplers. The accident scenarios generating the highest aerosol concentrations were, dropping a fungal plate, dropping a large bottle, centrifuge rotor leaks and a blocked syringe filter. Many of these accidents generated low particle size aerosols, which would be inhaled into the lungs of any exposed laboratory staff. Spray factors (SFs) have been calculated using the results of these experiments as an indicator of the potential for accidents to generate microbial aerosols. Model risk assessments have been described using the SF data. Quantitative risk assessment of laboratory accidents can provide data that can aid the design of containment laboratories and the response to laboratory accidents. A methodology has been described and supporting data provided to allow microbiological safety officers to carry out quantitative risk assessment of laboratory accidents.

  12. A constant flow filter air sampler for workplace environments

    International Nuclear Information System (INIS)

    Parulian, A.; Rodgers, J.C.; McFarland, A.R.

    1996-01-01

    A filter air sampler has been developed for sampling radionuclide aerosol particles form the workplace environment. It provides easy filter changing, constant flow sampling, and a visual display to indicate proper operation. An experimental study was conducted to characterize the collection efficiency of the sampler as affected by variations in room air velocity, particle size, sampling flow rate, inlet geometry, and inlet orientation to the free stream. Tests were carried out in a wing tunnel at velocities between 0.3 m s -1 and 2.0 m s -1 , which is a range that covers anticipated velocities in the typical highly ventilated workplace environment of a nuclear facility. Nearly monodisperse aerosols with sizes between 5 and 20 μm aerodynamic diameter were sampled at flow rates between 28.3 and 84.9 L min -1 . Inlet orientations of 0 degree, 90 degree, and 180 degree from the horizontal were selected for evaluation. When the sampler was oriented at 0 degree over various ranges of free stream velocities, sampling flow rates and particle sizes, the transmission efficiency of aerosol was typically greater than 95%. The transmission efficiencies varied form 80% to 106% for 10-μm aerodynamic diameter particles over the previously noted range of free stream velocities and inlet orientations. Uniformity of deposits of 10 μm aerodynamic diameter particles on collection filters was examined for a sampling rate of 57 L min -1 , a sampler orientation of 90 degree into the wind and wind speeds of 0.3-2 m s -1 . The coefficients of variation for the areal density of the deposits ranged from 6.1% to 37.2%. A miniature critical flow venturi with a constant sampling flow rate of 57 L min -1 was developed for application to the new filter air sampler. It was demonstrated that the performance of the new filter air sampler is quite acceptable over a wide range of conditions. 31 refs., 8 figs., 1 tab

  13. Elemental Concentration of Inhalable and Respirable Particulate ...

    African Journals Online (AJOL)

    20537 and respirable foam for I.O.M sampler. The elemental composition (Co, Ni, Zn, Cu, Fe, Pb, Cr, Mn and Cd) were analyzed by using Atomic Absorption Spectrophotometric (AAS). The data generated were subjected to descriptive analysis. In inhalable fraction,the enrichment factor ranged from 1-73.3 while in respirable ...

  14. Evaluation of air samplers and filter materials for collection and recovery of airborne norovirus.

    Science.gov (United States)

    Uhrbrand, K; Koponen, I K; Schultz, A C; Madsen, A M

    2018-04-01

    The aim of this study was to identify the most efficient sampling method for quantitative PCR-based detection of airborne human norovirus (NoV). A comparative experiment was conducted in an aerosol chamber using aerosolized murine norovirus (MNV) as a surrogate for NoV. Sampling was performed using a nylon (NY) filter in conjunction with four kinds of personal samplers: Gesamtstaubprobenahme sampler (GSP), Triplex-cyclone sampler (TC), 3-piece closed-faced Millipore cassette (3P) and a 2-stage NIOSH cyclone sampler (NIO). In addition, sampling was performed using the GSP sampler with four different filter types: NY, polycarbonate (PC), polytetrafluoroethylene (PTFE) and gelatine (GEL). The sampling efficiency of MNV was significantly influenced by both sampler and filter type. The GSP sampler was found to give significantly (P airborne NoV. The identification of a suitable NoV air sampler is an important step towards studying the association between exposure to airborne NoV and infection. © 2017 The Society for Applied Microbiology.

  15. Isokinetic sampler; Amostrador isocinetico

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Luis Cesar C. de; Santos, Antonio Carlos dos [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil); Barrio, Lara B.A. del [AZ Armaturen do Brasil Ltda., Itatiba, SP (Brazil); Silva, Claudio B. da C. e; Silva, Ricardo R. da [PETROBRAS, Rio de Janeiro, RJ (Brazil). Centro de Pesquisas

    2005-07-01

    The Center of Research Leopoldo A. Miguez de Melo - CENPES - in association with AZ Armaturen Company do Brasil and TRANSPETRO developed and tested an Isokinetic sampler. This work presents the sampling principles and the results and performance of the tests realized in the 'Sitio de Testes de Atalaia' and in one of the terminals of bunker transfer of TRANSPETRO - 'Terminal Aquaviario da Baia de Guanabara'. In the 'Sitio de Testes' the products used were oil and water with BSW from 5% to 97% and in the terminal were tested samplings of bunker with ranges viscosities between (MF 180 to 380). (author)

  16. Responses of low pressure Andersen sampler for collecting substrates

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, K. [Research Reactor Institute, Kyoto University, Osaka (Japan); Yamada, Y.; Miyamoto, K.; Shimo, M. [Division of Radiotoxicology and Protection, National Institute of Radiological Sciences, Chiba (Japan)

    2000-05-01

    Some types of low pressure cascade impactors (Andersen, Berner, Davies, and MOUDI etc) have been used to measure the activity size distribution of radon progeny in the environment. In spite of their careful uses, their nonideal responses are not adequately known. Some important factors such as the wall loss, electrostatic attraction, and the surface nature of collecting substrates may affect the reliability of the impactor data. Size selective characteristics of a low pressure Andersen sampler for various collecting substrates were examined in a radon exposure chamber using several kinds of liquid (DOS) or solid (carnauba wax) carrier aerosols labelled with radon progeny. These carrier aerosols were produced by commercial condensation aerosol generator. Tested collecting substrates were, (1) uncoated clean stainless steel plate, (2) silicone oil or grease coated stainless steel plate, (3) polyethylene sheet covered stainless steel plate, (4) membrane filter, (5) glass fiber filter, and (6) quartz fiber filter. In the case of collecting liquid or sticky carrier aerosols, the effect of particle bounce was small and nearly any substrates might used on the impaction plate. On the other hand, in the case of solid carrier aerosols, an adhesive layer such as grease or oil might have to be applied to the substrate. It was concluded that a low pressure cascade impactor such as Andersen sampler might need an appropriate calibration procedure including the interstage characteristics for determining the accurate activity size distribution. (author)

  17. Waveform Sampler CAMAC Module

    International Nuclear Information System (INIS)

    Freytag, D.R.; Haller, G.M.; Kang, H.; Wang, J.

    1985-09-01

    A Waveform Sampler Module (WSM) for the measurement of signal shapes coming from the multi-hit drift chambers of the SLAC SLC detector is described. The module uses a high speed, high resolution analog storage device (AMU) developed in collaboration between SLAC and Stanford University. The AMU devices together with high speed TTL clocking circuitry are packaged in a hybrid which is also suitable for mounting on the detector. The module is in CAMAC format and provides eight signal channels, each recording signal amplitude versus time in 512 cells at a sampling rate of up to 360 MHz. Data are digitized by a 12-bit ADC with a 1 μs conversion time and stored in an on-board memory accessible through CAMAC

  18. Aerosol generation and delivery in medical applications

    International Nuclear Information System (INIS)

    Soni, P.S.; Raghunath, B.

    1998-01-01

    It is well established that radioaerosol lung technique by inhalation is a very versatile technique in the evaluation of health effects and medical diagnostic applications, especially to detect chronic obstructive pulmonary diseases, their defence mechanism permeability and many others. Most important part of aerosol technology is to generate reproducibly stable diagnostic radioaerosols of known characteristics. Many compressed air atomisers are commercially available for generating aerosols but they have limited utility in aerosol inhalation, either because of large droplet size, low aerosol output or high airflow rates. There is clearly a need for a versatile and economical aerosol generation/inhalation system that can produce dry labelled aerosol particles with high deep lung delivery efficiency suitable for clinical studies. BARC (Bhabha Atomic Research Centre) has developed a dry aerosol generation/delivery system which operates on compressed air and generates dry polydisperse aerosols. This system is described along with an assessment of the aerosol characteristics and efficiency for diagnosis of various respiratory disorders

  19. Deposition and lung clearence of insoluble particles following acute inhalation of trichloroethylene; Andamento della deposizione e della clearance respiratoria nel ratto di aerosol insolubile in seguito ad inalazione acuta di tricloroetilene

    Energy Technology Data Exchange (ETDEWEB)

    Calamosca, M.; Pettinato, G.

    1993-12-31

    The effects of acute inhalation of trichloroethylene (TCE), emitted by automobiles as a combustion by-product, on the rat respiratory tract were investigated. In a previous work on mice, the observed damage proved to be limited to Clara cells (CC) and dose-dependent. Injury was correlated with the metabolic properties of CC, where TCE is converted to toxic intermediate metabolites. Since rat CC are located in the distal bronchial tree, a damage at this level is supposed to affect also the mechanical clearance of insoluble particles. Sprague-Dawley, female rats were exposed for 30 min, to a concentration of 3500 ppm TCE, to investigate the occurrence of an impairment of the mucousciliary/alveolar macrophagic (AM) removal system eventually correlated with epithelial damage. Nasopharyngeal and bronchopulmonary clearance patterns were obtained from the retention of a radio-labeled carnauba wax control aerosol, the rats inhaled 24 h after exposure to TCE. Sequential sacrifices, close together in time, were performed up to 24 h to detect the rapid clearance phase in all the different regions of the respiratory tract; from then on the retention was assessed in vivo by measuring the rats up to 600 h. A new mechanistic model was designed and applied to the retention data to achieve the parameters of relative deposition and the rates of clearance. Even if a major deposition in the bronchial region of the TCE test occurred, no significant differences were detected between all the parameters describing the clearance both of the bronchoalveolar and nasopharyngeal regions.

  20. Introduction to SamplerCompare

    Directory of Open Access Journals (Sweden)

    Madeleine B. Thompson

    2011-08-01

    Full Text Available SamplerCompare is an R package for comparing the performance of Markov chain Monte Carlo (MCMC samplers. It samples from a collection of distributions with a collection of MCMC methods over a range of tuning parameters. Then, using log density evaluations per uncorrelated observation as a figure of merit, it generates a grid of plots showing the results of the simulation. It comes with a collection of predefined distributions and samplers and provides R and C interfaces for defining additional ones. It also provides the means to import simulation data generated by external systems. This document provides background on the package and demonstrates the basics of running simulations, visualizing results, and defining distributions and samplers in R.

  1. Triadic split-merge sampler

    Science.gov (United States)

    van Rossum, Anne C.; Lin, Hai Xiang; Dubbeldam, Johan; van der Herik, H. Jaap

    2018-04-01

    In machine vision typical heuristic methods to extract parameterized objects out of raw data points are the Hough transform and RANSAC. Bayesian models carry the promise to optimally extract such parameterized objects given a correct definition of the model and the type of noise at hand. A category of solvers for Bayesian models are Markov chain Monte Carlo methods. Naive implementations of MCMC methods suffer from slow convergence in machine vision due to the complexity of the parameter space. Towards this blocked Gibbs and split-merge samplers have been developed that assign multiple data points to clusters at once. In this paper we introduce a new split-merge sampler, the triadic split-merge sampler, that perform steps between two and three randomly chosen clusters. This has two advantages. First, it reduces the asymmetry between the split and merge steps. Second, it is able to propose a new cluster that is composed out of data points from two different clusters. Both advantages speed up convergence which we demonstrate on a line extraction problem. We show that the triadic split-merge sampler outperforms the conventional split-merge sampler. Although this new MCMC sampler is demonstrated in this machine vision context, its application extend to the very general domain of statistical inference.

  2. Aerosol formulation and clinical efficacy of bronchodilators

    NARCIS (Netherlands)

    Zanen, Pieter

    1998-01-01

    This thesis subject is the improvement of the formulation of inhaled aerosols. It is well known that the formulation of inhaled drugs is not optimal: the major part of the mass delivered does not reach the lower airways. This phenomenon is due to the particle size of the inhaled particles, which

  3. Wind tunnel evaluation of the RAAMP sampler. Final report

    International Nuclear Information System (INIS)

    Vanderpool, R.W.; Peters, T.M.

    1994-11-01

    Wind tunnel tests of the Department of Energy RAAMP (Radioactive Atmospheric Aerosol Monitoring Program) monitor have been conducted at wind speeds of 2 km/hr and 24 km/hr. The RAAMP sampler was developed based on three specific performance objectives: (1) meet EPA PM10 performance criteria, (2) representatively sample and retain particles larger than 10 microm for later isotopic analysis, (3) be capable of continuous, unattended operation for time periods up to 2 months. In this first phase of the evaluation, wind tunnel tests were performed to evaluate the sampler as a potential candidate for EPA PM10 reference or equivalency status. As an integral part of the project, the EPA wind tunnel facility was fully characterized at wind speeds of 2 km/hr and 24 km/hr in conjunction with liquid test aerosols of 10 microm aerodynamic diameter. Results showed that the facility and its operating protocols met or exceeded all 40 CFR Part 53 acceptance criteria regarding PM10 size-selective performance evaluation. Analytical procedures for quantitation of collected mass deposits also met 40 CFR Part 53 criteria. Modifications were made to the tunnel's test section to accommodate the large dimensions of the RAAMP sampler's instrument case

  4. Morphology of the Ovaries in Condition of Inhalation Intoxication with Dust-Saline Aerosols of the Aral Sea in Female White Rats

    Directory of Open Access Journals (Sweden)

    Yasminur G. Turdybekova

    2018-06-01

    CONCLUSIONS: Taking into account the proven effect of dust-saline aerosols on the production of estrogen, the violation of the postovulatory phase of the ovarian cycle, we trace the mechanism of folliculogenesis disturbance. This confirms the data of our previous studies on primary and secondary infertility in women living in the Aral Sea region and the necessity of creation and development of preventive measures for the inhabitants of the region.

  5. Measurement of activity concentrations of {sup 40}K, 2{sup 32T}h and {sup 238}U in TSP aerosols and the associated inhalation annual effective radiation dose to the public in Gosan site, Jeju

    Energy Technology Data Exchange (ETDEWEB)

    Han, Chung Hun; Park, Youn Hyun; Park, Jae Woo [Jeju National University, Jeju (Korea, Republic of)

    2016-10-15

    Gamma radiation emitted from naturally occurring radioisotopes, such as 40K and the radionuclides from the {sup 232}Th and {sup 238}U series and their decay products, which exist at trace levels in all ground formations, represents the main external source of irradiation to the human body. The objective of the current study is to determine the activity concentrations of 40K, {sup 232}Th and {sup 238}U in airborne TSP and the associated internal radiation dose to the public due to inhalation in Gosan site, Jeju Island, Korea. The atmospheric total suspended particulates (TSP) aerosols were collected at Gosan site of Jeju Island, which is one of the background sites of Korea, during January to April 2013. This study analyzed using ICP-DRC-MS the concentrations of potassium, uranium and thorium, and evaluated the annual effective dose by breathing from the results. The correlations between the studied natural isotopes is a good positive correlation between {sup 232}Th and {sup 238}U, supporting the conclusion that they originated from the same source, mostly the crust. The backward trajectory analysis has confirmed that the 40K, {sup 238}U and {sup 232}Th are delivered as the air masses have moved from the China continent. The inhalation annual effective radiation dose (default mode F) to the public due to natural isotopes of the airborne TSP was in the range 16.195 - 77.051 nSv/y, depending on the age group. Jeju Island with less pollution source and low population density is also one of the best places as a background area in Asia.

  6. Effects of active inhalation of trichloroethylene on rat respiratory tract; Andamento della deposizione e della clearance respiratoria nel ratto di un aerosol insolubile in seguito ad inalazione acuta di tricloroetilene

    Energy Technology Data Exchange (ETDEWEB)

    Calamosca, M.; Pettinato, G. [ENEA, Bologna (Italy). Area Energia Ambiente e Salute

    1994-05-01

    The effects of an acute inhalation of tricloroethylene (TCE) on the rat respiratory tract have been investigated. In a previous work on mice, the observed damage proved to be limited to Clara cells (CC) and dose-dependent. Injury was correlated with the metabolic properties of CC, where TCE is converted to toxic intermediate metabolites. Since rat CC are located in the distal bronchial tree, a damage at this level is supposed to affect also the mechanical clearance of insoluble particles. Sprague-Dawley, female rats have been exposed for 30min, to a co 30min, to a concentration of 3500 ppm TCE, to investigate the occurrence of an impairment of the mucous-ciliary/alveolar macrophagic (AM) removal system eventually correlated with epithelial damage, whose results are presented in a different pubblication. Nasopharyngeal and bronchopulmonary clearance patterns were obtained from the retention of a radio-labeled carnauba wax control aerosol (0.70 mim CMAD, Sg < 1.08), the rats inhaled 24 h after esposure to TCE. Sequential sacrifices, close together in time, were performed up to 24 h to detect the rapid clearance phase in all the different regions of the respiratory tract; from then on the retention was assessed by in vivo measuring the rats up to 600 h. A new mechanistic model has been designed and applied to the retention data, to achieve the parameters of relative deposition and the rates of clearance. The statistical comparison of the parameter was carried over by means of the bootstrapping method. Even if a major deposition in the bronchial region of the TCE test occurs, no significant differences have been detected between all the parameters describing the clearance both of the bronchoalveolar and nasopharyngeal regions; neither the fraction of sequestered particles in the upper respiratory tract nor the laden AM particles transferred by the mucociliary escalator were significantly different compared with the control test.

  7. Pollution level and inhalation exposure of ambient aerosol fluoride as affected by polymetallic rare earth mining and smelting in Baotou, north China

    Science.gov (United States)

    Zhong, Buqing; Wang, Lingqing; Liang, Tao; Xing, Baoshan

    2017-10-01

    Airborne fluoride associated with total suspended particles (TSP) and respirable particulate (PM10) in the rare earth mining and smelting areas were analyzed during August 2012 and March 2013. In March, average concentrations of fluoride bound to TSP in the mining and smelting areas were 0.598 ± 0.626 μg/m3 and 3.615 ± 4.267 μg/m3, respectively, whereas that in August were 0.699 ± 0.801 μg/m3 and 1.917 ± 2.233 μg/m3, respectively. TSP samples were classified into four categories by different sampling periods and locations using Kohonen's self-organizing map, which demonstrates that high airborne fluoride concentrations in March in the smelting area were probably attributed to industrial emissions from smelting activities and wind-blown dust from tailings pond, influenced by meteorologic parameters such as temperature, relative humidity, precipitation and wind speed. The mean daily amount of fluoride inhaled in the mining and smelting areas were estimated to be in the range of 2.77-57.61 μg/day and 3.39-64.32 μg/day, respectively. These results indicate the high potential exposure level of fluoride inhaled for local residents in the polymetallic mining and smelting areas.

  8. Mexico City aerosol study

    International Nuclear Information System (INIS)

    Falcon, Y.I.; Ramirez, C.R.

    1987-01-01

    A major task in the field of air pollution monitoring is the development of devices for determining the mass and composition of airborne particulate matter as a function of size - and time. The sample collection device must be designed giving consideration to the nature of the aerosol and to the effects of the aerosol on human health. It has been established that particles smaller than 3.5 μm in diameter can penetrate deeply into the human respiratory system, and that larger particles are trapped in the upper respiratory passages. For these reasons, it is desirable to use a dichotomous sampler to collect particles in two size ranges, rather than to collect total particulates on a single filter. The authors discuss a study in Mexico City using a dichotomous sampler

  9. Influence of Aerosol Properties and the Respiratory Pattern upon Hazards Evaluation following Inhalation Exposure; Influence des Caracteristiques des Aerosols et du Regime de la Respiration sur l'Evaluation des Risques, a la Suite d'une Exposition par Inhalation; Vliyanie svojstv aehrozolej i obraztsa respiratora na otsenku opasnosti oblucheniya pri vdykhanii radioaktivnykh veshchestv; Influencia de las Propriedades de los Aerosoles y de su Esquema Repiratorio en la Evaluacion de los Riesgos Consecutivos a una Exposicion por Inhalacion

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, R. G. [Lovelace Foundation for Medical Education and Research, Albuquerque, NM (United States)

    1964-10-15

    There are three important biological parameters which are necessary in evaluating the hazards from compounds entering the body by any route. These are (1) the amount deposited in-the body; (2) the distribution and translocation kinetics within the body; and (3) the rate of excretion of the material. Sufficient quantitative data on these points are generally lacking in the case of an accidental exposure. This paper deals with experimental animal studies correlating different physical and chemical characteristics of inhaled particles with the three biological variables mentioned above. Values for the amount and location of deposited material as a function of the particle size inhaled is presented for a tissue soluble compound (caesium chloride) and for a tissue ''insoluble'' compound (thorium chloride). Evidence is also given to substantiate the variations which occur in tissue distribution and excretion of an element, depending upon its physical and chemical state when breathed. Data from experiments with aerosols of many compounds, including those already mentioned, is used to show a unique correlation between body burden and faecal excretion during the first few post-exposure days. The advantages in performing analyses on both urine and faeces for bioassay purposes is demonstrated. The fallacies in current methods of practical hazard assessment from air sampling and bioassay techniques are stressed throughout, using the above data as examples. (author) [French] Pour evaluer les risques dus aux composes qui penetrent dans l'organisme par une voie quelconque, il faut tenir compte de trois parametres biologiques importants: 1. Quantite deposee dans l'organisme; 2. Cinetique de la repartition et de la translocation a l'interieur de l'organisme; 3. Vitesse de l'excretion de la matiere consideree. Dans le cas d'une exposition accidentelle, on manque generalement de donnees quantitatives suffisantes sur ces parametres. Le memoire a trait a des etudes experimentales qui

  10. Quantification and risks associated with bacterial aerosols near domestic greywater-treatment systems.

    Science.gov (United States)

    Benami, Maya; Busgang, Allison; Gillor, Osnat; Gross, Amit

    2016-08-15

    Greywater (GW) reuse can alleviate water stress by lowering freshwater consumption. However, GW contains pathogens that may compromise public health. During the GW-treatment process, bioaerosols can be produced and may be hazardous to human health if inhaled, ingested, or come in contact with skin. Using air-particle monitoring, BioSampler®, and settle plates we sampled bioaerosols emitted from recirculating vertical flow constructed wetlands (RVFCW) - a domestic GW-treatment system. An array of pathogens and indicators were monitored using settle plates and by culturing the BioSampler® liquid. Further enumeration of viable pathogens in the BioSampler® liquid utilized a newer method combining the benefits of enrichment with molecular detection (MPN-qPCR). Additionally, quantitative microbial risk assessment (QMRA) was applied to assess risks of infection from a representative skin pathogen, Staphylococcus aureus. According to the settle-plate technique, low amounts (0-9.7×10(4)CFUm(-2)h(-1)) of heterotrophic bacteria, Staphylococcus spp., Pseudomonas spp., Klebsiella pneumoniae, Enterococcus spp., and Escherichia coli were found to aerosolize up to 1m away from the GW systems. At the 5m distance amounts of these bacteria were not statistically different (p>0.05) from background concentrations tested over 50m away from the systems. Using the BioSampler®, no bacteria were detected before enrichment of the GW-aerosols. However, after enrichment, using an MPN-qPCR technique, viable indicators and pathogens were occasionally detected. Consequently, the QMRA results were below the critical disability-adjusted life year (DALY) safety limits, a measure of overall disease burden, for S. aureus under the tested exposure scenarios. Our study suggests that health risks from aerosolizing pathogens near RVFCW GW-treatment systems are likely low. This study also emphasizes the growing need for standardization of bioaerosol-evaluation techniques to provide more accurate

  11. Design of dry sand soil stratified sampler

    Science.gov (United States)

    Li, Erkang; Chen, Wei; Feng, Xiao; Liao, Hongbo; Liang, Xiaodong

    2018-04-01

    This paper presents a design of a stratified sampler for dry sand soil, which can be used for stratified sampling of loose sand under certain conditions. Our group designed the mechanical structure of a portable, single - person, dry sandy soil stratified sampler. We have set up a mathematical model for the sampler. It lays the foundation for further development of design research.

  12. Differences in particle size distributions collected by two wood dust samplers: preliminary findings

    International Nuclear Information System (INIS)

    Campopiano, A.; Olori, A.; Basili, F.; Ramires, D.; Zakrzewska, A.M.

    2008-01-01

    The International Agency for Research on Cancer (IARC) classification of wood dust as carcinogenic to humans, and the threshold limit value (TLV) of 5 mg/m 3 weighted over an 8-hour work day as defined by Italian legislation, have raised the issue of dust risk assessments in all woodworking environments. The aim is to characterize the particle size distribution for wood particles collected by two samplers used for collecting the inhalable fraction: the IOM sampler (Institute of Occupational Medicine, Edinburgh, Scotland) and the conical sampler also known in Italy as conetto. These two sampling heads were chosen mainly because the Italian conical sampler, used in the past for total dust sampling, is the most widely used by the Italian Prevention Services and analysis laboratories in general, whereas the IOM sampler was specifically designed to collect the inhalable fraction of airborne particles. The devices were placed side by side within the worker's breathing zone. In addition, another IOM sampler not connected to the personal sampling pump was placed on the same worker, thus functioning as a passive sampler capable of collecting projectile particles normally produced during processing. A Scanning Electron Microscope (SEM) coupled with energy dispersive X-ray spectrometry (EDAX) was used to count the number of particles collected on the sampling filters. The size of each particle identified by the SEM was determined by measuring its mean diameter. The SEM analysis revealed that the average size of the largest particles collected by the conetto sampler did not exceed 150 μm, whereas the size of particles collected by the IOM sampler was up to 350 μm. Indeed, the analysis of the filters of the passive IOM samplers showed that particles with mean diameters larger than 100 μm were collected, although the calculated percentage was very low (on average, approximately 1%). This does not mean that their gravimetric contribution is negligible; indeed, the weight of

  13. Dosage of DTPA administration by inhalation

    International Nuclear Information System (INIS)

    Koizumi, Akira; Fukuda, Satoshi; Yamada, Yuji; Iida, Haruzo; Shimo, Michikuni

    2000-01-01

    The administration of DTPA by inhalation was examined as an emergency medical treatment. In order to estimate the practical dosage to the human, an accurate model of the human air way was connected to a anesthetizer and respiration was simulated. Ca-DTPA, aerosolized by an ultra-sonic nebulizer, was administered by inhalation to the model. For the experiments, the respiratory volume (tidal volume) and the respiration rate was 12 per minute. Irrigation water from the model of larynx and mouth, and the air filter were collected and measured by chelate titration in order to determine the quantity of aerosolized DTPA and the amount deposited on the trachea and lang. The results indicated that the quantity of aerosolized DTPA varied with dilution of the DTPA solution in a ample. It was found that a 3 time dilution was the most practical and that 73 mg of DTPA per minute could be aerosolized. Furthermore, the results indicated that 46% of the aerosolized DTPA was taken in through inhalation and that 26% of DTPA was deposited in the trachea and lung. These results suggest that in practical application in the emergency medical treatment, 15 minutes of inhalation could delivered to approximately 500 mg of DTPA, and 130 mg could be delivered to the trachea and lung. It is considered that these quantity are enough amount to increase the effects of radioactive nuclides from the body, comparing with the recommended dosage for injection administration. (author)

  14. An aerosole generator for production of radioactive aerosoles by evaporating uranium dioxide

    International Nuclear Information System (INIS)

    Pusch, W.M.

    1975-01-01

    In the Institut for Biology of the Austrian Research Center at Seibersdorf an experiment is running to study the behaviour of radioactive aerosoles in the organism of miniature swines after inhalation. In the work under discussion the aerosole generator of the equipment used for this inhalation experiments is described by means of which the aerosole-air mixtures are produced. The main part of this generator is a gas burner for evaporating irradiated UO 2 -pellets. (orig.) [de

  15. Inhaled Drug Delivery: A Practical Guide to Prescribing Inhaler Devices

    Directory of Open Access Journals (Sweden)

    Pierre Ernst

    1998-01-01

    Full Text Available Direct delivery of medication to the target organ results in a high ratio of local to systemic bioavailability and has made aerosol delivery of respiratory medication the route of choice for the treatment of obstructive lung diseases. The most commonly prescribed device is the pressurized metered dose inhaler (pMDI; its major drawback is the requirement that inspiration and actuation of the device be well coordinated. Other requirements for effective drug delivery include an optimal inspiratory flow, a full inspiration from functional residual capacity and a breath hold of at least 6 s. Available pMDIs are to be gradually phased out due to their use of atmospheric ozone-depleting chlorofluorocarbons (CFCs as propellants. Newer pMDI devices using non-CFC propellants are available; preliminary experience suggests these devices greatly increase systemic bioavailability of inhaled corticosteroids. The newer multidose dry powder inhalation devices (DPIs are breath actuated, thus facilitating coordination with inspiration, and contain fewer ingredients. Furthermore, drug delivery is adequate even at low inspired flows, making their use appropriate in almost all situations. Equivalence of dosing among different devices for inhaled corticosteroids will remain imprecise, requiring the physician to adjust the dose of medication to the lowest dose that provides adequate control of asthma. Asthma education will be needed to instruct patients on the effective use of the numerous inhalation devices available.

  16. Influence of hilar deposition in the evaluation of the alveolar epithelial permeability on 99mTc-DTPA aerosol inhaled scintigraphy

    International Nuclear Information System (INIS)

    Ogi, Shigeyuki; Uchiyama, Mayuki; Fukuda, Kunihiko; Urashima, Mitsuyoshi; Gotoh, Eisuke; Fukumitsu, Nobuyoshi

    2009-01-01

    We investigated whether hilar radioaerosol deposition affects the clearance rate of technetium-99m-labeled diethylenetriaminepentaacetic acid ( 99m Tc-DTPA) from peripheral alveolar regions. A total of 38 patients underwent 99m Tc-DTPA inhalation lung scintigraphy. Six region of interest (ROI) patterns were adopted: ROI 1 was outlined around the entire hemithorax, and ROIs 2-6 were outlined around the hemithorax but excluded square ROIs of different size in the hilar region. Half-times (T 1/2 ) were calculated with time-activity curves using one-compartment and two-compartment analyses. The T 1/2 of ROIs 1-5 were plotted against the T 1/2 of ROI 6, and regression lines were obtained with the least-squares method. The absolute values of the differences between surveyed values and regression line were calculated. The Wilcoxon test for trend and a single linear regression model were used to determine statistical significance. There were significant reductions in the absolute values of the differences between surveyed values and regression line from ROIs 1-5 by one-component analysis and the fast component of two-compartment analysis (P 99m Tc-DTPA from the alveoli in damaged lungs. The hilar region should be excluded from ROIs when alveolar epithelial permeability is evaluated. (author)

  17. Inhalation Toxicology Research Institute annual report, October 1, 1983-September 30, 1984

    International Nuclear Information System (INIS)

    Guilmette, R.A.; Medinsky, M.A.

    1984-12-01

    The report describes research in the following areas: (1) aerosol generation and characterization; (2) deposition and fate of inhaled materials; (3) dose-response relationships for inhaled radionuclides; (4) dose-response relationships for inhaled chemical toxicants; and (5) biological factors that influence dose-response relationships. Project descriptions have been individually entered into the date base

  18. Detection of Infectious Influenza Virus in Cough Aerosols Generated in a Simulated Patient Examination Room

    Science.gov (United States)

    Noti, John D.; Lindsley, William G.; Blachere, Francoise M.; Cao, Gang; Kashon, Michael L.; Thewlis, Robert E.; McMillen, Cynthia M.; King, William P.; Szalajda, Jonathan V.; Beezhold, Donald H.

    2015-01-01

    Background The potential for aerosol transmission of infectious influenza virus (ie, in healthcare facilities) is controversial. We constructed a simulated patient examination room that contained coughing and breathing manikins to determine whether coughed influenza was infectious and assessed the effectiveness of an N95 respirator and surgical mask in blocking transmission. Methods National Institute for Occupational Safety and Health aerosol samplers collected size-fractionated aerosols for 60 minutes at the mouth of the breathing manikin, beside the mouth, and at 3 other locations in the room. Total recovered virus was quantitated by quantitative polymerase chain reaction and infectivity was determined by the viral plaque assay and an enhanced infectivity assay. Results Infectious influenza was recovered in all aerosol fractions (5.0% in >4 µm aerodynamic diameter, 75.5% in 1–4 µm, and 19.5% in <1 µm; n = 5). Tightly sealing a mask to the face blocked entry of 94.5% of total virus and 94.8% of infectious virus (n = 3). A tightly sealed respirator blocked 99.8% of total virus and 99.6% of infectious virus (n = 3). A poorly fitted respirator blocked 64.5% of total virus and 66.5% of infectious virus (n = 3). A mask documented to be loosely fitting by a PortaCount fit tester, to simulate how masks are worn by healthcare workers, blocked entry of 68.5% of total virus and 56.6% of infectious virus (n = 2). Conclusions These results support a role for aerosol transmission and represent the first reported laboratory study of the efficacy of masks and respirators in blocking inhalation of influenza in aerosols. The results indicate that a poorly fitted respirator performs no better than a loosely fitting mask. PMID:22460981

  19. Particle integrity, sampling, and application of a DNA-tagged tracer for aerosol transport studies

    Energy Technology Data Exchange (ETDEWEB)

    Kaeser, Cynthia Jeanne [Michigan State Univ., East Lansing, MI (United States)

    2017-07-21

    Aerosols are an ever-present part of our daily environment and have extensive effects on both human and environmental health. Particles in the inhalable range (1-10 μm diameter) are of particular concern because their deposition in the lung can lead to a variety of illnesses including allergic reactions, viral or bacterial infections, and cancer. Understanding the transport of inhalable aerosols across both short and long distances is necessary to predict human exposures to aerosols. To assess the transport of hazardous aerosols, surrogate tracer particles are required to measure their transport through occupied spaces. These tracer particles must not only possess similar transport characteristics to those of interest but also be easily distinguished from the background at low levels and survive the environmental conditions of the testing environment. A previously-developed DNA-tagged particle (DNATrax), composed of food-grade sugar and a DNA oligonucleotide as a “barcode” label, shows promise as a new aerosol tracer. Herein, the use of DNATrax material is validated for use in both indoor and outdoor environments. Utilizing passive samplers made of materials commonly found in indoor environments followed by quantitative polymerase chain reaction (qPCR) assay for endpoint particle detection, particles detection was achieved up to 90 m from the aerosolization location and across shorter distances with high spatial resolution. The unique DNA label and PCR assay specificity were leveraged to perform multiple simultaneous experiments. This allowed the assessment of experimental reproducibility, a rare occurrence among aerosol field tests. To transition to outdoor testing, the solid material provides some protection of the DNA label when exposed to ultraviolet (UV) radiation, with 60% of the DNA remaining intact after 60 minutes under a germicidal lamp and the rate of degradation declining with irradiation time. Additionally, exposure of the DNATrax material using

  20. Inhalation of antibiotics in cystic fibrosis

    NARCIS (Netherlands)

    Touw, D J; Brimicombe, R W; Hodson, M E; Heijerman, H G; Bakker, W

    Aerosol administration of antipseudomonal antibiotics is commonly used in cystic fibrosis. However, its contribution to the improvement of lung function, infection and quality of life is not well-established. All articles published from 1965 until the present time concerning the inhalation of

  1. Toxicological perspectives of inhaled therapeutics and nanoparticles.

    Science.gov (United States)

    Hayes, Amanda J; Bakand, Shahnaz

    2014-07-01

    The human respiratory system is an important route for the entry of inhaled therapeutics into the body to treat diseases. Inhaled materials may consist of gases, vapours, aerosols and particulates. In all cases, assessing the toxicological effect of inhaled therapeutics has many challenges. This article provides an overview of in vivo and in vitro models for testing the toxicity of inhaled therapeutics and nanoparticles implemented in drug delivery. Traditionally, inhalation toxicity has been performed on test animals to identify the median lethal concentration of airborne materials. Later maximum tolerable concentration denoted by LC0 has been introduced as a more ethically acceptable end point. More recently, in vitro methods have been developed, allowing the direct exposure of airborne material to cultured human target cells on permeable porous membranes at the air-liquid interface. Modifications of current inhalation therapies, new pulmonary medications for respiratory diseases and implementation of the respiratory tract for systemic drug delivery are providing new challenges when conducting well-designed inhalation toxicology studies. In particular, the area of nanoparticles and nanocarriers is of critical toxicological concern. There is a need to develop toxicological test models, which characterise the toxic response and cellular interaction between inhaled particles and the respiratory system.

  2. A rotating bluff-body disc for reduced variability in wind tunnel aerosol studies.

    Science.gov (United States)

    Koehler, Kirsten A; Anthony, T Renee; van Dyke, Michael; Volckens, John

    2011-01-01

    A rotating bluff-body disc (RBD) was developed to reduce spatiotemporal variability associated with sampling supermicron aerosol in low-velocity wind tunnels. The RBD is designed to rotate eight personal aerosol samplers around a circular path in a forward-facing plane aligned with the wind tunnel cross section. Rotation of the RBD allows each sampler to traverse an identical path about the wind tunnel cross section, which reduces the effects of spatial heterogeneity associated with dispersing supermicron aerosol in low-velocity wind tunnels. Samplers are positioned on the face of the RBD via sampling ports, which connect to an air manifold on the back of the disc. Flow through each sampler was controlled with a critical orifice or needle valve, allowing air to be drawn through the manifold with a single pump. A metal tube, attached to this manifold, serves as both the axis of rotation and the flow conduction path (between the samplers and the vacuum source). Validation of the RBD was performed with isokinetic samplers and 37-mm cassettes. For facing-the-wind tests, the rotation of the RBD significantly decreased intra-sampler variability when challenged with particle diameters from 1 to 100 μm. The RBD was then employed to determine the aspiration efficiency of Institute of Occupational Medicine (IOM) personal samplers under a facing-the-wind condition. Operation of IOM samplers on the RBD reduced the between-sampler variability for all particle sizes tested.

  3. Characterization of an aerosol sample from the auxiliary building of the Three Mile Island reactor.

    Science.gov (United States)

    Kanapilly, G M; Stanley, J A; Newton, G J; Wong, B A; DeNee, P B

    1983-11-01

    Analyses for radioisotopic composition and dissolution characteristics were performed on an aerosol filter sample collected for a week by an air sampler located in the auxiliary building of the Three Mile Island nuclear reactor. The major radioisotopes found on the filter were 89Sr, 90Sr, 134Cs and 137Cs. Greater than 90% of both 89-90Sr and 134-137Cs dissolved within 48 hr in an in vitro test system. Scanning electron microscopic analyses showed the presence of respirable size particles as well as larger particles ranging up to 10 micron in diameter. The major matrix components were Fe, Ca, S, Mg, Al and Si. Although the radionuclides were present in a heterogeneous matrix, they were in a soluble form. This information enables a better evaluation of bioassay data and predictions of dose distribution resulting from an inhalation exposure to this aerosol. Further, the combination of techniques used in this study may be applicable to the characterization of other aerosols of unknown composition.

  4. Assessment of personal exposure to airborne nanomaterials: Evaluation of a novel sampler

    International Nuclear Information System (INIS)

    Faure, Bertrand; Dozol, Hélène; Brouard, Christophe; Guiot, Arnaud; Clavaguera, Simon

    2017-01-01

    A novel sampler, the NANOBADGE, has been developed to assess personal exposure to nano-objects, agglomerates and aggregates (NOAA) at the workplace. The NANOBADGE collects particles on filters subsequently analyzed by X-Ray Fluorescence spectroscopy (XRF), which provides a mass-based quantification with chemical selectivity. The NANOBADGE was benchmarked against a scanning mobility particle sizer (SMPS) and a DiSCmini by carrying out simultaneous measurements on test aerosols of ZnO or TiO 2 for particle sizes between 20 and 400 nm for which the DiSCmini has its highest accuracy. The effective density and shape of the NOAA present in the test aerosols were determined experimentally to compare number-based data obtained with the SMPS and the DiSCmini with mass-based data obtained with the NANOBADGE. The agreement between the SMPS and the NANOBADGE sampler was within ± 25 % on all test aerosols. The converted DiSCmini data matched the SMPS and sampler data for polydisperse aerosols in the specified size range as long as the DiSCmini assumptions meet the aerosol characteristics (i.e. lognormal size distribution with a given geometric standard deviation σg = 1.9). The detection limits of the NANOBADGE sampler were in the order of tens of nanograms per filter, which is low enough to reliably detect exposure levels below the recommended exposure limit (REL) of the National Institute for Occupational Safety and Health (NIOSH) and the Institut National de Recherche et de Sécurité (INRS) for ultrafine ZnO and TiO 2 even for short-term exposure situations. (paper)

  5. Remote Sampler Demonstration Isolok Configuration Test

    International Nuclear Information System (INIS)

    Kelly, Steve E.

    2016-01-01

    The accuracy and precision of a new Isolok sampler configuration was evaluated using a recirculation flow loop. The evaluation was performed using two slurry simulants of Hanford high-level tank waste. Through testing, the capability of the Isolok sampler was evaluated. Sample concentrations were compared to reference samples that were simultaneously collected by a two-stage Vezin sampler. The capability of the Isolok sampler to collect samples that accurately reflect the contents in the test loop improved – biases between the Isolok and Vezin samples were greatly reduce for fast settling particles.

  6. Remote Sampler Demonstration Isolok Configuration Test

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Steve E. [Washington River Protection Solutions, LLC, Richland, WA (United States)

    2016-06-08

    The accuracy and precision of a new Isolok sampler configuration was evaluated using a recirculation flow loop. The evaluation was performed using two slurry simulants of Hanford high-level tank waste. Through testing, the capability of the Isolok sampler was evaluated. Sample concentrations were compared to reference samples that were simultaneously collected by a two-stage Vezin sampler. The capability of the Isolok sampler to collect samples that accurately reflect the contents in the test loop improved – biases between the Isolok and Vezin samples were greatly reduce for fast settling particles.

  7. Inhaled budesonide for treatment of recurrent wheezing in early childhood

    DEFF Research Database (Denmark)

    Bisgaard, H; Munck, Susanne; Nielsen, J P

    1990-01-01

    77 children, aged 11 to 36 months (mean 24) with moderately severe recurrent wheezing, were treated with budesonide pressurised aerosol 400 micrograms twice daily or placebo for 12 weeks in a double-blind, parallel-group trial. Aerosols were inhaled from a spacer with a facemask. Budesonide...... be ascribed to the active treatment. The findings indicate that young children below 3 years of age can inhale a pressurised aerosol from a spacer with a facemask. Use of topically active glucocorticosteroids with this simple device may reduce symptoms and distress in young children with moderately severe...

  8. Tropospheric Aerosols

    Science.gov (United States)

    Buseck, P. R.; Schwartz, S. E.

    2003-12-01

    m, PM10=1.1 μg m-3; estimated coefficient of light scattering by particulate matter, σep, at 570 nm=12 Mm-1). (b) High aerosol concentration (PM2.5=43.9 μg m-3; PM10=83.4 μg m-3; estimated σep at 570 nm=245 Mm-1) (reproduced by permission of National Park Service, 2002). Although comprising only a small fraction of the mass of Earth's atmosphere, aerosol particles are highly important constituents of the atmosphere. Special interest has focused on aerosols in the troposphere, the lowest part of the atmosphere, extending from the land or ocean surface typically to ˜8 km at high latitudes, ˜12 km in mid-latitudes, and ˜16 km at low latitudes. That interest arises in large part because of the importance of aerosol particles in geophysical processes, human health impairment through inhalation, environmental effects through deposition, visibility degradation, and influences on atmospheric radiation and climate.Anthropogenic aerosols are thought to exert a substantial influence on Earth's climate, and the need to quantify this influence has sparked much of the current interest in and research on tropospheric aerosols. The principal mechanisms by which aerosols influence the Earth radiation budget are scattering and absorbing solar radiation (the so-called "direct effects") and modifying clouds and precipitation, thereby affecting both radiation and hydrology (the so-called "indirect effects"). Light scattering by aerosols increases the brightness of the planet, producing a cooling influence. Light-absorbing aerosols such as black carbon exert a warming influence. Aerosols increase the reflectivity of clouds, another cooling influence. These radiative influences are quantified as forcings, where a forcing is a perturbation to the energy balance of the atmosphere-Earth system, expressed in units of watts per square meter, W m-2. A warming influence is denoted a positive forcing, and a cooling influence, negative. The radiative direct and indirect forcings by

  9. Comparison of particulate matter exposure estimates in young children from personal sampling equipment and a robotic sampler.

    Science.gov (United States)

    Sagona, Jessica A; Shalat, Stuart L; Wang, Zuocheng; Ramagopal, Maya; Black, Kathleen; Hernandez, Marta; Mainelis, Gediminas

    2017-05-01

    Accurate characterization of particulate matter (PM) exposure in young children is difficult, because personal samplers are often too heavy, bulky or impractical to be used. The Pretoddler Inhalable Particulate Environmental Robotic (PIPER) sampler was developed to help address this problem. In this study, we measured inhalable PM exposures in 2-year-olds via a lightweight personal sampler worn in a small backpack and evaluated the use of a robotic sampler with an identical sampling train for estimating PM exposure in this age group. PM mass concentrations measured by the personal sampler ranged from 100 to almost 1,200 μg/m 3 , with a median value of 331 μg/m 3 . PM concentrations measured by PIPER were considerably lower, ranging from 14 to 513 μg/m 3 with a median value of 56 μg/m 3 . Floor cleaning habits and activity patterns of the 2-year-olds varied widely by home; vigorous play and recent floor cleaning were most associated with higher personal exposure. Our findings highlight the need for additional characterization of children's activity patterns and their effect on personal exposures.

  10. Determination of respirable-sized crystalline silica in different ambient environments in the United Kingdom with a mobile high flow rate sampler utilising porous foams to achieve the required particle size selection

    Science.gov (United States)

    Stacey, Peter; Thorpe, Andrew; Roberts, Paul; Butler, Owen

    2018-06-01

    Inhalation of respirable crystalline silica (RCS) can cause diseases including silicosis and cancer. Levels of RCS close to an emission source are measured but little is known about the wider ambient exposure from industry emissions or natural sources. The aim of this work is to report the RCS concentrations obtained from a variety of ambient environments using a new mobile respirable (PM4) sampler. A mobile battery powered high flow rate (52 L min-1) sampler was developed and evaluated for particulate aerosol sampling employing foams to select the respirable particle size fraction. Sampling was conducted in the United Kingdom at site boundaries surrounding seven urban construction and demolition and five sand quarry sites. These are compared with data from twelve urban aerosol samples and from repeat measurements from a base line study at a single rural site. The 50% particle size penetration (d50) through the foam was 4.3 μm. Over 85% of predict bias values were with ±10% of the respirable convention, which is based on a log normal curve. Results for RCS from all construction and quarry activities are generally low with a 95 th percentile of 11 μg m-3. Eighty percent of results were less than the health benchmark value of 3 μg m-3 used in some states in America for ambient concentrations. The power cutting of brick and the largest demolition activities gave the highest construction levels. Measured urban background RCS levels were typically below 0.3 μg m-3 and the median RCS level, at a rural background location, was 0.02 μg m-3. These reported ambient RCS concentrations may provide useful baseline values to assess the wider impact of fugitive, RCS containing, dust emissions into the wider environment.

  11. Inhaled plutonium oxide in dogs

    International Nuclear Information System (INIS)

    Park, J.F.

    1982-01-01

    This project is concerned with long-term experiments to determine the lifespan dose-effect relationships of inhaled 239 PuO 2 and 238 PuO 2 in beagles. Beagle dogs given a single exposure to 239 PuO 2 or 238 PuO 2 aerosols are being observed for lifespan dose-effect relationships. The 239 Pu body burden of the nine dogs that died of pulmonary-fibrosis-induced respiratory insufficiency during the first 3 yr after exposure was 1 to 12μCi. Nineteen of the dogs exposed to 238 Pu haved died during the first 7-1/2 yr after exposure due to bone and/or lung tumors; their body burdens at death ranged from 0.7 to 10μCi. Chronic lymphopenia was the earliest observed effect after inhalation of 239 PuO 2 or 238 PuO 2

  12. Is Distant Pollution Contaminating Local Air? Analyzing the Origins of Atmospheric Aerosols

    Directory of Open Access Journals (Sweden)

    David Geng

    2012-01-01

    Full Text Available Understanding the origin of aerosols in the atmosphere is important because of visual pollution, climate impacts, and deleterious health effects due to the inhalation of fine particles. This research analyzed aerosols characterized by their chloride, sulfate, and nitrate content as a function of size over a 3-month period. Due to wind patterns over coal-burning power plants, a higher concentration of local sulfate pollution was expected. Aerosols were harvested on the Purdue University campus using a high-volume air sampler with glass fiber filters and a five-stage impactor that separates the aerosols into five sizes. The filters were extracted in water to dissolve anions and the solution was analyzed using high-pressure liquid ion chromatography. Only trace amounts of chloride with no distinct patterns in size were detected. In total, nitrate content ranged from 0.12 to 2.10 μg/m3 and sulfate content ranged from 0.44 to 6.45 μg/m3 over a 3-month period. As for fine particles, a higher concentration of sulfate was observed. The Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT model determines air mass origin, and in this study, higher total sulfate content was observed when the air mass moved out of the southwest, and higher total nitrate content was observed when the air mass originated from the southeast. The author concluded that small particles resulted in sulfate from sulfur dioxide, typically from gas to particle conversion. High sulfur dioxide levels are directly correlated with coal-burning power plant density. Small particulate sulfate found in West Lafayette, Indiana, was determined to originate primarily from power plants in southwest Indiana. Though the results do show a significant amount of potentially harmful aerosols in West Lafayette, there is still further research to be done concerning isotopic composition of those particles in attempts to better explain the chemical pathways.

  13. Inhalation drug delivery devices: technology update

    Directory of Open Access Journals (Sweden)

    Ibrahim M

    2015-02-01

    Full Text Available Mariam Ibrahim, Rahul Verma, Lucila Garcia-ContrerasDepartment of Pharmaceutical Sciences, College of Pharmacy, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, USAAbstract: The pulmonary route of administration has proven to be effective in local and systemic delivery of miscellaneous drugs and biopharmaceuticals to treat pulmonary and non-pulmonary diseases. A successful pulmonary administration requires a harmonic interaction between the drug formulation, the inhaler device, and the patient. However, the biggest single problem that accounts for the lack of desired effect or adverse outcomes is the incorrect use of the device due to lack of training in how to use the device or how to coordinate actuation and aerosol inhalation. This review summarizes the structural and mechanical features of aerosol delivery devices with respect to mechanisms of aerosol generation, their use with different formulations, and their advantages and limitations. A technological update of the current state-of-the-art designs proposed to overcome current challenges of existing devices is also provided.Keywords: pulmonary delivery, asthma, nebulizers, metered dose inhaler, dry powder inhaler

  14. Radioactive content in aerosols and rainwater

    International Nuclear Information System (INIS)

    Rodriguez Perestelo, N.; Lopez Perez, M.; Rodriguez, S.; Duarte, X.; Catalan, A.; Fernandez de Aldecoa, J. C.; Hernandez, J.

    2013-01-01

    The environmental radiological characterization of a place requires knowledge of the radioactive contents of its components, such as air (aerosol), rain, soil, etc ... Inhalation of radioactive aerosols in the air remains the main component of the total dose to the world population. This work focuses on its determination. (Author)

  15. Inhalation Toxicology Research Institute. Annual report, October 1, 1981-September 30, 1982

    International Nuclear Information System (INIS)

    Snipes, M.B.; Marshall, T.C.; Martinez, B.S.

    1982-12-01

    Studies are presented of the effect on man of airborne particulates and gaseous emissions associated with the production of energy. Included in the report from the Inhalation Toxicology Research Institute are papers on: (1) the physical and chemical characterization of energy technology aerosols; (2) laboratory studies of aerosol generation and characterization; (3) in vitro predictors of toxicity; (4) disposition and fate of inhaled materials; (5) dose-response relationships for inhaled radionuclides; (6) dose-response relationships for inhaled chemical toxicants; (7) biological factors which influence dose-response relationships; and (8) risk assessment

  16. A Comparison of Gravimetric and Photometric Aerosol Samplers

    Science.gov (United States)

    2009-03-24

    the potential to cause disease (Vincent, 2007; Meldrum , 1996; and ATSDR, 2001). f) Fog – discernible mist that floats in air and usually settles to...atomization, such as spraying or arising from acid baths in chrome plating. The droplets are homogenous with the parent material and range from xvi...Contaminant Control. Boston, Butterworth Publishers. Meldrum , M. (1996). Review of fibre toxicology. H.S.E. Report, London, UK, Health and Safety

  17. 7 CFR 61.30 - Examination of sampler.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Examination of sampler. 61.30 Section 61.30... Cottonseed Samplers § 61.30 Examination of sampler. Each applicant for a license as a sampler and each... examination or test to show his ability properly to perform the duties for which he is applying for a license...

  18. Inhaled plutonium oxide in dogs

    International Nuclear Information System (INIS)

    Park, J.F.

    1985-01-01

    This project is concerned with long-term experiments to determine the lifespan dose-effect relationships of inhaled 239 PuO 2 and 238 PuO 2 in beagles. The data will be used to estimate the health effects of inhaled transuranics. Beagle dogs given a single exposure to 239 PuO 2 or 238 PuO 2 aerosols to obtain graded levels of initial lung burdens are being observed for lifespan dose-effect relationships. Mortality due to radiation pneumonitis and lung tumor increased in the four highest dose-level groups exposed to 239 PuO 2 , during the 13-yr postexposure period. During the 10 1/2 years after exposure to 238 PuO 2 , mortality due to lung and/or bone tumors increased in the three highest dose-level groups. Chronic lymphopenia, occurring 0.5 to 2 year after exposure, was the earliest observed effect after inhalation of either 239 PuO 2 or 238 PuO 2 in the four highest dose-level groups that had initial lung burdens greater than or equal to 80 nCi. 3 figures, 6 tables

  19. Cardiomyopathy from 1,1-Difluoroethane Inhalation.

    Science.gov (United States)

    Kumar, Suwen; Joginpally, Tejaswini; Kim, David; Yadava, Mrinal; Norgais, Konchok; Laird-Fick, Heather S

    2016-10-01

    Consumer aerosol products can be inhaled for their psychoactive effects, but with attendant adverse health effects including "sudden sniffing death." Cardiomyopathy has rarely been described in association with 1,1-difluoroethane (DFE), a common aerosol propellant. We report a 33-year-old male who developed acute myocardial injury and global hypokinesis along with rhabdomyolysis, acute kidney injury, and fulminant hepatitis after 2 days' nearly continuous huffing. Workup for other causes, including underlying coronary artery disease, was negative. His cardiac function improved over time. The exact mechanism of DFE's effects is uncertain but may include catecholamine-induced cardiomyopathy, coronary vasospasm, or direct cellular toxicity.

  20. Experimental typing of the entry efficiency in calm air of an annular slot sampler; Determination experimentale de l'efficacite de captage en air calme d'un echantillonneur a fente annulaire

    Energy Technology Data Exchange (ETDEWEB)

    Roger, F.; Fabries, J.F.; Gorner, P.; Wrobel, R. [Institut National de Recherche et de Securite, INRS, Lab. de Metrologie de la Pollution par les Aerosols, 54 - Vandoeuvre-Les-Nancy (France); Renoux, A. [Paris-12 Univ., Lab. de Physique des Aerosols et de Transfert des Contaminations, 94 - Creteil (France)

    2000-07-01

    Aerosol sampling is a complex physical process that depends on many parameters like particle size, wind speed, aspiration velocity and sampler geometry. Inertia has a predominant influence on particle motion in moving air for particle size above 1 {mu}m. In calm air where air movement is mainly induced by the aspiration orifice of the sampler, gravitational settling affects more deeply particle motion and hence sampler performance. The entry efficiency of a sampler with an annular aspiration slot was recently measured for several conditions of aspiration flow rate, wind speed (1 and 3 m s{sup -1}) and geometric parameters of the sampler as a function of particle aerodynamic diameter. Some complementary work was carried out to add new experimental data corresponding to the same sampler in calm air. The results were obtained for 9 configurations, combining several values of disc diameter, aspiration slot width, and aspiration velocity. A semi-empirical model was developed from the data that enables the calculation of particle entry efficiency of the annular sampler in calm air. In addition, a numerical study was carried out to calculate the particle trajectories approaching the annular aspiration slot of the sampler. The results show that particle rebounds on the sampler walls have a significant effect on the entry efficiency of the sampler in calm air. (authors)

  1. Inhalation Therapy in Horses.

    Science.gov (United States)

    Cha, Mandy L; Costa, Lais R R

    2017-04-01

    This article discusses the benefits and limitations of inhalation therapy in horses. Inhalation drug therapy delivers the drug directly to the airways, thereby achieving maximal drug concentrations at the target site. Inhalation therapy has the additional advantage of decreasing systemic side effects. Inhalation therapy in horses is delivered by the use of nebulizers or pressured metered dose inhalers. It also requires the use of a muzzle or nasal mask in horses. Drugs most commonly delivered through inhalation drug therapy in horses include bronchodilators, antiinflammatories, and antimicrobials. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. A study on characteristics and sources of winter time atmospheric aerosols in Kyoto and Seoul using PIXE and supplementary analysis

    International Nuclear Information System (INIS)

    Ma, C.-J.; Kasahara, M.; Tohno, S.; Yeo, H.-G.

    1999-01-01

    Atmospheric aerosols were collected using a two stages filter sampler to classify into the fine and coarse fraction in Kyoto and Seoul in winter season. Elemental concentrations of aerosols were analyzed by PIXE and EAS as well as ion concentrations by IC. Analyzed data were used to source of aerosol particles. (author)

  3. UWB Sampler for Wireless Communications and Radar

    National Research Council Canada - National Science Library

    Han, Jeongwoo; Nguyen, Cam

    2005-01-01

    An ultra wideband (UWB) sampler, realized using step recovery and Schottky diodes on coplanar waveguide, coplanar strips and slotlines, has been developed for UWB wireless communications and radar systems...

  4. A passive sampler for atmospheric ozone

    International Nuclear Information System (INIS)

    Grosjean, D.; Hisham, M.W.M.

    1992-01-01

    A simple, cost-effective passive sampler has been developed for the determination of atmospheric ozone. This passive sampler is based on a colorant which fades upon reaction with ozone, whose concentration can be determined by reflectance measurement of the color change. Direct, on-site measurements are possible, and no chemical analyses are needed. Sampler design and validation studies have been carried out and included quantitative determination of color change vs exposure time (1-8 days), color change vs. ozone concentration (30-350 ppb), and response to changes in sampler configuration that modify the passive sampling rate. With indigo carmine as the colorant, the detection limits are 30 ppb. day and 120 ppb. day using a plastic grid and Teflon filter, respectively, as diffusion barriers. Interferences from nitrogen dioxide, formaldehyde and peroxyacetyl nitrate are 15, 4 and 16%, respectively, thus resulting in a negligible bias when measuring ozone in ambient air

  5. Sampler collection gadget for epilithic diatoms.

    Science.gov (United States)

    Salomoni, S E; Torgan, L C; Rocha, O

    2007-11-01

    This work present a new gadget for sampling epilithic diatoms from both lentic and lotic enviroments. The sampler consists of a polystyrene cylinder, left to float on the surface of the water, to which stone substrates are attached. This epilithic diatom sampler (EDS) can be used to detect spatial and temporal richness and density variation in the study of the diatom community, as well as in water quality monitoring.

  6. Sampler collection gadget for epilithic diatoms

    Directory of Open Access Journals (Sweden)

    SE. Salomoni

    Full Text Available This work present a new gadget for sampling epilithic diatoms from both lentic and lotic enviroments. The sampler consists of a polystyrene cylinder, left to float on the surface of the water, to which stone substrates are attached. This epilithic diatom sampler (EDS can be used to detect spatial and temporal richness and density variation in the study of the diatom community, as well as in water quality monitoring.

  7. A new experimental facility for studying aerosol sampling in workplace environments

    International Nuclear Information System (INIS)

    Fauvel, S.; Witstchger, O.

    2000-01-01

    The european council directive 96/29/EURATOM requires its implementation into national regulations. This directive lays down basic safety standards for the protection of the health of workers and the general public against the dangers arising from ionizing radiations. This directive allows to use aerosol characteristics (particle size distribution, airborne concentration, morphology and chemical composition) measured in workplace to assess the effective radiation dose of workers resulting from the intake by inhalation of airborne radionuclides. Tests of performances of instruments used for the health-related sampling of particles in workplace are usually carried out in a wind tunnel or a calm air chamber. In these test conditions, instruments are exposed to uniform wind and steady homogeneous aerosol. In a real workplace situation, these instruments are usually exposed to highly non-uniform airflows and local emissions of particles. Moreover, it is not clear how differences in airflow pattern, proximity of the localised contamination source, worker location or activity would affect the personal/static measurement ratio. The objective of our experimental work is to investigate the relevant parameters that affect the aerosol characteristics in the microenvironment of a worker (including breathing zone) and in the workplace. The first part of that study was to design and built an experimental room CEPIA (french acronym for room for studying personal and area samplers). The ventilated chamber (volume 36 m 3 ) is equipped with an air delivery system to insure different ventilation patterns and flowrates. The CEPIA chamber should offer possibilities for performing experiments in situations representing a workplace environment, with airflows and aerosol parameters well controlled and characterised. (authors)

  8. Radioactive content in aerosols and rainwater; Contenido radiactivo en aerosoles y agua de lluvia

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Perestelo, N.; Lopez Perez, M.; Rodriguez, S.; Duarte, X.; Catalan, A.; Fernandez de Aldecoa, J. C.; Hernandez, J.

    2013-07-01

    The environmental radiological characterization of a place requires knowledge of the radioactive contents of its components, such as air (aerosol), rain, soil, etc ... Inhalation of radioactive aerosols in the air remains the main component of the total dose to the world population. This work focuses on its determination. (Author)

  9. Pulmonary aerosol delivery and the importance of growth dynamics.

    Science.gov (United States)

    Haddrell, Allen E; Lewis, David; Church, Tanya; Vehring, Reinhard; Murnane, Darragh; Reid, Jonathan P

    2017-12-01

    Aerosols are dynamic systems, responding to variations in the surrounding environmental conditions by changing in size, composition and phase. Although, widely used in inhalation therapies, details of the processes occurring on aerosol generation and during inhalation have received little attention. Instead, research has focused on improvements to the formulation of the drug prior to aerosolization and the resulting clinical efficacy of the treatment. Here, we highlight the processes that occur during aerosol generation and inhalation, affecting aerosol disposition when deposited and, potentially, impacting total and regional doses. In particular, we examine the response of aerosol particles to the humid environment of the respiratory tract, considering both the capacity of particles to grow by absorbing moisture and the timescale for condensation to occur. [Formula: see text].

  10. Ciclesonide Oral Inhalation

    Science.gov (United States)

    ... use ciclesonide inhalation.Ciclesonide inhalation helps to prevent asthma attacks (sudden episodes of shortness of breath, wheezing, and coughing) but will not stop an asthma attack that has already started. Do not use ciclesonide ...

  11. Flunisolide Oral Inhalation

    Science.gov (United States)

    ... use flunisolide inhalation.Flunisolide inhalation helps to prevent asthma attacks (sudden episodes of shortness of breath, wheezing, and coughing) but will not stop an asthma attack that has already started. Do not use flunisolide ...

  12. Inhalation Toxicology Research Institute annual report, October 1, 1993--September 30, 1994

    International Nuclear Information System (INIS)

    Belinsky, S.A.; Hoover, M.D.; Bradley, P.L.

    1994-11-01

    This document from the Inhalation Toxicology Research Institute includes annual reports in the following general areas: (I) Aerosol Technology and Characterization of Airborne Materials; (II) Deposition, transport, and clearance of inhaled Toxicants; (III) Metabolism and Markers of Inhaled Toxicants; (IV) Carcinogenic Responses to Toxicants; (V) Mechanisms of carcinogenic response to Toxicants; (VI) Non carcinogenic responses to inhaled toxicants; (VII) Mechanisms of noncarcinogenic Responses to Inhaled Toxicants; (VIII) The application of Mathematical Modeling to Risk Estimates. 9 appendices are also included. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  13. Inhalation Toxicology Research Institute annual report, October 1, 1993--September 30, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Belinsky, S. A.; Hoover, M. D.; Bradley, P. L. [eds.

    1994-11-01

    This document from the Inhalation Toxicology Research Institute includes annual reports in the following general areas: (I) Aerosol Technology and Characterization of Airborne Materials; (II) Deposition, transport, and clearance of inhaled Toxicants; (III) Metabolism and Markers of Inhaled Toxicants; (IV) Carcinogenic Responses to Toxicants; (V) Mechanisms of carcinogenic response to Toxicants; (VI) Non carcinogenic responses to inhaled toxicants; (VII) Mechanisms of noncarcinogenic Responses to Inhaled Toxicants; (VIII) The application of Mathematical Modeling to Risk Estimates. 9 appendices are also included. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  14. Sampling of high amounts of bioaerosols using a high-volume electrostatic field sampler

    DEFF Research Database (Denmark)

    Madsen, A. M.; Sharma, Anoop Kumar

    2008-01-01

    For studies of the biological effects of bioaerosols, large samples are necessary. To be able to sample enough material and to cover the variations in aerosol content during and between working days, a long sampling time is necessary. Recently, a high-volume transportable electrostatic field...... and 315 mg dust (net recovery of the lyophilized dust) was sampled during a period of 7 days, respectively. The sampling rates of the electrostatic field samplers were between 1.34 and 1.96 mg dust per hour, the value for the Gravikon was between 0.083 and 0.108 mg dust per hour and the values for the GSP...... samplers were between 0.0031 and 0.032 mg dust per hour. The standard deviations of replica samplings and the following microbial analysis using the electrostatic field sampler and GSP samplers were at the same levels. The exposure to dust in the straw storage was 7.7 mg m(-3) when measured...

  15. Hydrazine inhalation hepatotoxicity.

    Science.gov (United States)

    Kao, Yung Hsiang; Chong, C H; Ng, W T; Lim, D

    2007-10-01

    Abstract Hydrazine is a hazardous chemical commonly used as a reactant in rocket and jet fuel cells. Animal studies have demonstrated hepatic changes after hydrazine inhalation. Human case reports of hydrazine inhalation hepatotoxicity are rare. We report a case of mild hepatotoxicity following brief hydrazine vapour inhalation in a healthy young man, which resolved completely on expectant management.

  16. Statistical analysis of the DWPF prototypic sampler

    International Nuclear Information System (INIS)

    Postles, R.L.; Reeve, C.P.; Jenkins, W.J.; Bickford, D.F.

    1991-01-01

    The DWPF process will be controlled using assay measurements on samples of feed slurry. These slurries are radioactive, and thus will be sampled remotely. A Hydraguard trademark pump-driven sampler system will be used as the remote sampling device. A prototype Hydraguard trademark sampler has been studied in a full-scale mock-up of a DWPF process vessel. Two issues were of dominant interest: (1) what accuracy and precision can be provided by such a pump-driven sampler in the face of the slurry rheology; and, if the Hydraguard trademark sample accurately represents the slurry in its local area, (2) is the slurry homogeneous enough throughout for it to represent the entire vessel? To determine Hydraguard trademark Accuracy, a Grab Sampler of simpler mechanism was used as reference. This (Low) Grab Sampler was located as near to the intake port of the Hydraguard trademark as could be arranged. To determine Homogeneity, a second (High) Grab Sampler was located above the first. The data necessary to these determinations comes from the measurement system, so its important variables also affect the results. Thus, the design of the test involved not just Sampling variables, but also some of the Measurement variables as well. However, the main concern was the Sampler and not the Measurement System, so the test design included only such measurement variables as could not be circumvented (Vials, Dissolution Method, and Aliquoting). The test was executed by, or under the direct oversight of, expert technologists. It thus did not explore the many important particulars of ''routine'' plant operations (such as Remote Sample Preparation or Laboratory Shift Operation)

  17. Sampling polyhexamethylene guanidine aerosols using eosin Y-coated glass beads

    International Nuclear Information System (INIS)

    Choi, Sang Hyun; Park, Seon Kyung; Kang, Hyun Joong; Kwon, Jung Hwan; Lee, Kyu Hong

    2015-01-01

    Fatalities caused by the use of polyhexamethylene guanidine (PHMG), a general-purpose chemical germicide used as a humidifier disinfectant in Korea, have raised concerns about exposure to biocide aerosols in indoor environments. A sampler capable of accumulating PHMG from aqueous aerosols was developed as an alternative to low-volume air samplers. This sampler was prepared by placing glass beads coated with 2-(2,4,5,7-tetrabromo-6-oxido-3-oxo-3H-xanthen-9-yl)benzoate (Eosin Y) in a custom-made plastic holder. Passive sampling rates, measured in a bench-top exposure chamber at two different aqueous PHMG aerosol generation rates, were found to be independent of the experimental conditions. This suggests that the capacity of the sampler to accumulate the PHMG aerosol was sufficient for the sampling duration tested. However, the passive sampling rate was 7.6 × 10"−"6 m"3/h for the sampler area of 22 cm"2. This rate is lower than the typical human breathing rate and inadequate for quantitative instrumental analyses at low concentrations in indoor air. A 30-fold enhancement of the sampling rate was achieved by forced convection using a commercial battery-operated fan at ≥2000 rpm. With this accelerated sampling rate, the sampler could be used to monitor time-integrated concentrations of PHMG aerosols in the air

  18. Sampling polyhexamethylene guanidine aerosols using eosin Y-coated glass beads

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sang Hyun; Park, Seon Kyung; Kang, Hyun Joong; Kwon, Jung Hwan [Korea University, Seoul (Korea, Republic of); Lee, Kyu Hong [Korea Institute of Toxicology, Jeongeup (Korea, Republic of)

    2015-07-15

    Fatalities caused by the use of polyhexamethylene guanidine (PHMG), a general-purpose chemical germicide used as a humidifier disinfectant in Korea, have raised concerns about exposure to biocide aerosols in indoor environments. A sampler capable of accumulating PHMG from aqueous aerosols was developed as an alternative to low-volume air samplers. This sampler was prepared by placing glass beads coated with 2-(2,4,5,7-tetrabromo-6-oxido-3-oxo-3H-xanthen-9-yl)benzoate (Eosin Y) in a custom-made plastic holder. Passive sampling rates, measured in a bench-top exposure chamber at two different aqueous PHMG aerosol generation rates, were found to be independent of the experimental conditions. This suggests that the capacity of the sampler to accumulate the PHMG aerosol was sufficient for the sampling duration tested. However, the passive sampling rate was 7.6 × 10{sup −6} m{sup 3}/h for the sampler area of 22 cm{sup 2}. This rate is lower than the typical human breathing rate and inadequate for quantitative instrumental analyses at low concentrations in indoor air. A 30-fold enhancement of the sampling rate was achieved by forced convection using a commercial battery-operated fan at ≥2000 rpm. With this accelerated sampling rate, the sampler could be used to monitor time-integrated concentrations of PHMG aerosols in the air.

  19. Aerosolization of fungi, (1→3)-β-D glucan, and endotoxin from flood-affected materials collected in New Orleans homes

    Science.gov (United States)

    Adhikari, Atin; Jung, Jaehee; Reponen, Tiina; Lewis, Jocelyn Suzanne; DeGrasse, Enjoli C.; Grimsley, L. Faye; Chew, Ginger L.; Grinshpun, Sergey A.

    2015-01-01

    Standing water and sediments remaining on flood-affected materials were the breeding ground for many microorganisms in flooded homes following Hurricane Katrina. The purpose of this laboratory study was to examine the aerosolization of culturable and total fungi, (1→3)-β-D glucan, and endotoxin from eight flood-affected floor and bedding materials collected in New Orleans homes, following Hurricane Katrina. Aerosolization was examined using the Fungal Spore Source Strength Tester (FSSST) connected to a BioSampler. Dust samples were collected by vacuuming. A two-stage cyclone sampler was used for size-selective analysis of aerosolized glucan and endotoxin. On average, levels of culturable fungi ranged from undetectable (lower limit = 8.3×104) to 2.6×105 CFU/m2; total fungi ranged from 2.07×105 to 1.6×106 spores/m2; (1→3)-β-D glucan and endotoxin were 2.0×103 – 2.9×104 ng/m2 and 7.0×102 – 9.3×104 EU/m2, respectively. The results showed that 5–15 min sampling is sufficient for detecting aerosolizable biocontaminants with the FSSST. Smaller particle size fractions (1.8 μm) fractions, which raises additional exposure concerns. Vacuuming was found to overestimate inhalation exposure risks by a factor of approximately 102 for (1→3)-β-D glucan and by 103 to 104 for endotoxin as detected by the FSSST. The information generated from this study is important with respect to restoration and rejuvenation of the flood-affected areas in New Orleans. We believe the findings will be significant during similar disasters in other regions of the world including major coastal floods from tsunamis. PMID:19201399

  20. Quantity and Quality of Inhaled Dose Predicts Immunopathology in Tuberculosis

    Directory of Open Access Journals (Sweden)

    Kevin Patrick Fennelly

    2015-06-01

    Full Text Available Experimental animal models of tuberculosis (TB have convincingly demonstrated that inhaled dose predicts immunopathology and survival. In contrast, the importance of inhaled dose has generally not been appreciated in TB epidemiology, clinical science, or the practice of TB control. Infectiousness of TB patients has traditionally been assessed using microscopy for acid-fast bacilli in the sputum, which should be considered only a risk factor. We have recently demonstrated that cough aerosol cultures from index cases with pulmonary TB are the best predictors of new infection among household contacts. We suggest that cough aerosols of M. tuberculosis are the best surrogates of inhaled dose, and we hypothesize that the quantity of cough aerosols is associated with TB infection versus disease. Although several factors affect the quality of infectious aerosols, we propose that the particle size distribution of cough aerosols is an important predictor of primary upper airway disease and cervical lymphadenitis and of immune responses in exposed hosts. We hypothesize that large droplet aerosols (> 5 microns containing M. tuberculosis deposit in the upper airway and can induce immune responses without establishing infection. We suggest that this may partially explain the large proportion of humans who never develop TB disease in spite of having immunological evidence of M. tuberculosis infection (e.g. positive TST or IGRA. If these hypotheses are proven true, they would alter the current paradigm of latent TB infection and reactivation, further demonstrating the need for better biomarkers or methods of assessing TB infection and the risk of developing disease.

  1. Environmental HTO/HT sampler development

    International Nuclear Information System (INIS)

    Workman, W.J.G.; Brown, R.M.; Wood, M.J.

    1992-12-01

    Tests of retention by several drying agents of HTO from an air stream containing HT have been performed. Two batches of Molecular Sieve (MS) 4A retained up to 1.3% of HT passed through them in contrast to material tested in 1986, when retention was -4 . Retention of 10 -5 to 10 -6 was observed for DRIERITE (anhydrous calcium sulphate) and Silica Gel. DRIERITE is preferred over Silica Gel as a desiccant in an air sampler for environmental HTO/HT, because it is much easier to decontaminate for reuse. An improved air sampler has been designed, 2 units constructed and components procured for 3 more. The air sampler may be line or battery operated, accommodates up to four 120 g drier or oxidizer traps, and will pump up to 4 L/min for up to 24 hours on battery power. It is build into a rugged aluminum case and weighs approximately 11 kg overall, facilitating deployment in the field

  2. Coalescent genealogy samplers: windows into population history.

    Science.gov (United States)

    Kuhner, Mary K

    2009-02-01

    Coalescent genealogy samplers attempt to estimate past qualities of a population, such as its size, growth rate, patterns of gene flow or time of divergence from another population, based on samples of molecular data. Genealogy samplers are increasingly popular because of their potential to disentangle complex population histories. In the last decade they have been widely applied to systems ranging from humans to viruses. Findings include detection of unexpected reproductive inequality in fish, new estimates of historical whale abundance, exoneration of humans for the prehistoric decline of bison and inference of a selective sweep on the human Y chromosome. This review summarizes available genealogy-sampler software, including data requirements and limitations on the use of each program.

  3. Relative efficiencies of the Burkard 7-Day, Rotorod and Burkard Personal samplers for Poaceae and Urticaceae pollen under field conditions

    DEFF Research Database (Denmark)

    Peel, Robert George; Kennedy, Roy; Smith, Matt

    2014-01-01

    Introduction: In aerobiological studies it is often necessary to compare concentration data recorded with different models of sampling instrument. Sampler efficiency typically varies from device to device, and depends on the target aerosol and local atmospheric conditions. To account for these di...

  4. Case study of water-soluble metal containing organic constituents of biomass burning aerosol

    Science.gov (United States)

    Alexandra L. Chang-Graham; Luisa T. M. Profeta; Timothy J. Johnson; Robert J. Yokelson; Alexander Laskin; Julia Laskin

    2011-01-01

    Natural and prescribed biomass fires are a major source of aerosols that may persist in the atmosphere for several weeks. Biomass burning aerosols (BBA) can be associated with long-range transport of water-soluble N-, S-, P-, and metal-containing species. In this study, BBA samples were collected using a particle-into-liquid sampler (PILS) from laboratory burns of...

  5. Overflow type sodium sampler for FBTR circuits

    International Nuclear Information System (INIS)

    Muralidaran, P.; Ganesan, V.; Chandran, K.; Periaswami, G.

    1996-01-01

    Obtaining a representative sample is crucial for getting reliable results in sodium analysis. Sampling liquid sodium reliability is complicated since impurities segregate while cooling. Selective sorption of certain elements calls for use of different crucible materials for various sodium impurities. Sampling methods currently in use such as flow through sampling and dip sampling are not the proper methods as they can not take care of the above problems. An overflow type sampler where the entire sample contained in a crucible can be used for analysis thus obviating problems due to segregation has been developed for use in Fast Breeder Test Reactor (FBTR). This report describes the construction and operation of this sampler. (author)

  6. Fast monitoring of indoor bioaerosol concentrations with ATP bioluminescence assay using an electrostatic rod-type sampler.

    Directory of Open Access Journals (Sweden)

    Ji-Woon Park

    Full Text Available A culture-based colony counting method is the most widely used analytical technique for monitoring bioaerosols in both indoor and outdoor environments. However, this method requires several days for colony formation. In this study, our goal was fast monitoring (Sampling: 3 min, Detection: < 1 min of indoor bioaerosol concentrations with ATP bioluminescence assay using a bioaerosol sampler. For this purpose, a novel hand-held electrostatic rod-type sampler (110 mm wide, 115 mm long, and 200 mm tall was developed and used with a commercial luminometer, which employs the Adenosine triphosphate (ATP bioluminescence method. The sampler consisted of a wire-rod type charger and a cylindrical collector, and was operated with an applied voltage of 4.5 kV and a sampling flow rate of 150.7 lpm. Its performance was tested using Staphylococcus epidermidis which was aerosolized with an atomizer. Bioaerosol concentrations were measured using ATP bioluminescence method with our sampler and compared with the culture-based method using Andersen cascade impactor under controlled laboratory conditions. Indoor bioaerosol concentrations were also measured using both methods in various indoor environments. A linear correlation was obtained between both methods in lab-tests and field-tests. Our proposed sampler with ATP bioluminescence method may be effective for fast monitoring of indoor bioaerosol concentrations.

  7. Operability test report for 211BA flow proportional sampler

    International Nuclear Information System (INIS)

    Weissenfels, R.D.

    1995-01-01

    This operability report will verify that the 211-BA flow proportional sampler functions as intended by design. The sampler was installed by Project W-007H and is part of BAT/AKART for the BCE liquid effluent stream

  8. Potential consequences of yellowcake inhalation

    International Nuclear Information System (INIS)

    Eidson, A.F.; Damon, E.G.; Hahn, F.F.; Pickrell, J.A.; Muggenburg, B.A.

    1988-01-01

    The uranium ore milling process includes dusty operations and workers can be exposed to aerosols of highly concentrated uranium. Measurements made during uranium milling operations were used to predict that, if a worker was not wearing respiratory protection, 0.14-50 μg U/min might be deposited in the respiratory tract, predominantly in the nesopharyngeal compartment. Yellowcake was shown by infrared and solubility measurements to be a highly variable mixture of ammonium diuranate and U 3 O 8 . Biokinetic studies of inhaled yellowcake in beagle dogs showed that the more soluble fraction caused kidney damage. After inhalation of 0.5 mg U/kg body wt of soluble uranium, kidney concentration was 0.3 to 3.5 μg U/g kidney within 4-8 days; and was accompanied by kidney damage. Kidney damage was neither severe nor widespread, and was repaired within 64 days after exposure. The damage seen is due to heavy metal nephrotoxicity of uranium, and not to radiation damage

  9. Electrostatics of Pharmaceutical Aerosols for Pulmonary Delivery.

    Science.gov (United States)

    Lip Kwok, Philip Chi

    2015-01-01

    This paper provides a review on key research findings in the rapidly developing area of pharmaceutical aerosol electrostatics. Solids and liquids can become charged without electric fields, the former by contact or friction and the latter by flowing or spraying. Therefore, charged particles and droplets carrying net charges are produced from pharmaceutical inhalers (e.g. dry powder inhalers, metered dose inhalers, and nebulisers) due to the mechanical processes involved in aerosolisation. The charging depends on many physicochemical factors, such as formulation composition, solid state properties, inhaler material and design, and relative humidity. In silico, in vitro, and limited in vivo studies have shown that electrostatic charges may potentially influence particle deposition in the airways. However, the evidence is not yet conclusive. Furthermore, there are currently no regulatory requirements on the characterisation and control of the electrostatic properties of inhaled formulations. Besides the need for further investigations on the relationship between physicochemical factors and charging characteristics of the aerosols, controlled and detailed in vivo studies are also required to confirm whether charges can affect particle deposition in the airways. Since pharmaceutical aerosol electrostatics is a relatively new research area, much remains to be explored. Thus there is certainly potential for development. New findings in the future may contribute to the advancement of pharmaceutical aerosol formulations and respiratory drug delivery.

  10. Criteria for inhalation exposure systems utilizing concurrent flow spirometry

    International Nuclear Information System (INIS)

    Raabe, O.G.; Yeh, H.C.

    1974-01-01

    Principles are given for the design and operation of a new class of inhalation exposure systems utilizing concurrent flow spirometry (CFS), a simple method for providing realtime measurement of respiratory volumes and rates during inhalation exposure by mouth or nose of individual experimental animals or man to aerosols or gases. This technique is especially useful for inhalation exposure of larger experimental animals, such as horses, where whole-body plethysmography is usually impractical. Difficulties encountered with conventional exposure systems in maintenance of uniform aerosol or gas concentrations and prevention of large pressure excursions in the exposure chamber during breathing are obviated by systems utilizing the principles of concurrent flow spirometry. For illustration, two exposure units with CFS are described, one for exposure of Beagle dogs and one for ponies. (U.S.)

  11. A Comparison of "Total Dust" and Inhalable Personal Sampling for Beryllium Exposure

    Energy Technology Data Exchange (ETDEWEB)

    Carter, Colleen M. [Tulane Univ., New Orleans, LA (United States). School of Public Health and Tropical Medicine

    2012-05-09

    In 2009, the American Conference of Governmental Industrial Hygienists (ACGIH) reduced the Beryllium (Be) 8-hr Time Weighted Average Threshold Limit Value (TLV-TWA) from 2.0 μg/m3 to 0.05 μg/m3 with an inhalable 'I' designation in accordance with ACGIH's particle size-selective criterion for inhalable mass. Currently, per the Department of Energy (DOE) requirements, the Lawrence Livermore National Laboratory (LLNL) is following the Occupational Health and Safety Administration (OSHA) Permissible Exposure Limit (PEL) of 2.0 μg/m3 as an 8-hr TWA, which is also the 2005 ACGIH TLV-TWA, and an Action Level (AL) of 0.2 μg/m3 and sampling is performed using the 37mm (total dust) sampling method. Since DOE is considering adopting the newer 2009 TLV guidelines, the goal of this study was to determine if the current method of sampling using the 37mm (total dust) sampler would produce results that are comparable to what would be measured using the IOM (inhalable) sampler specific to the application of high energy explosive work at LLNL's remote experimental test facility at Site 300. Side-by-side personal sampling using the two samplers was performed over an approximately two-week period during chamber re-entry and cleanup procedures following detonation of an explosive assembly containing Beryllium (Be). The average ratio of personal sampling results for the IOM (inhalable) vs. 37-mm (total dust) sampler was 1.1:1 with a P-value of 0.62, indicating that there was no statistically significant difference in the performance of the two samplers. Therefore, for the type of activity monitored during this study, the 37-mm sampling cassette would be considered a suitable alternative to the IOM sampler for collecting inhalable particulate matter, which is important given the many practical and economic advantages that it presents. However, similar comparison studies would be necessary for this conclusion to be

  12. Particle capturing performance of South African non corrosive samplers

    CSIR Research Space (South Africa)

    Pretorius, C

    2010-05-01

    Full Text Available eq ue nc y D50 D90 © CSIR 2007 www.csir.co.za Particle size distribution of sampled filters taken in three platinum mines PSA results according to mine 0 2 4 6 8 10 12 14 16 X-Samplers Y-Samplers X-Samplers Y...

  13. Development of a High Efficiency Dry Powder Inhaler: Effects of Capsule Chamber Design and Inhaler Surface Modifications

    Science.gov (United States)

    Behara, Srinivas R.B.; Farkas, Dale R.; Hindle, Michael; Longest, P. Worth

    2013-01-01

    Purpose The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. Methods DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. Results The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. Conclusions High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD 90%, and ED > 80%. PMID:23949304

  14. Development of a high efficiency dry powder inhaler: effects of capsule chamber design and inhaler surface modifications.

    Science.gov (United States)

    Behara, Srinivas R B; Farkas, Dale R; Hindle, Michael; Longest, P Worth

    2014-02-01

    The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD  90%, and ED > 80%.

  15. Inhalant allergies in children.

    Science.gov (United States)

    Mims, James W; Veling, Maria C

    2011-06-01

    Children with chronic or recurrent upper respiratory inflammatory disease (rhinitis) should be considered for inhalant allergies. Risk factors for inhalant allergies in children include a first-degree relative with allergies, food allergy in infancy, and atopic dermatitis. Although inhalant allergies are rare in infancy, inhalant allergies are common in older children and impair quality of life and productivity. Differentiating between viral and allergic rhinitis can be challenging in children, but the child's age, history, and risk factors can provide helpful information. Allergic rhinitis is a risk factor for asthma, and if one is present, medical consideration of the other is warranted. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Inhalant Abuse and Dextromethorphan.

    Science.gov (United States)

    Storck, Michael; Black, Laura; Liddell, Morgan

    2016-07-01

    Inhalant abuse is the intentional inhalation of a volatile substance for the purpose of achieving an altered mental state. As an important, yet underrecognized form of substance abuse, inhalant abuse crosses all demographic, ethnic, and socioeconomic boundaries, causing significant morbidity and mortality in school-aged and older children. This review presents current perspectives on epidemiology, detection, and clinical challenges of inhalant abuse and offers advice regarding the medical and mental health providers' roles in the prevention and management of this substance abuse problem. Also discussed is the misuse of a specific "over-the-counter" dissociative, dextromethorphan. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Development of high efficiency ventilation bag actuated dry powder inhalers.

    Science.gov (United States)

    Behara, Srinivas R B; Longest, P Worth; Farkas, Dale R; Hindle, Michael

    2014-04-25

    New active dry powder inhaler systems were developed and tested to efficiently aerosolize a carrier-free formulation. To assess inhaler performance, a challenging case study of aerosol lung delivery during high-flow nasal cannula (HFNC) therapy was selected. The active delivery system consisted of a ventilation bag for actuating the device, the DPI containing a flow control orifice and 3D rod array, and streamlined nasal cannula with separate inlets for the aerosol and HFNC therapy gas. In vitro experiments were conducted to assess deposition in the device, emitted dose (ED) from the nasal cannula, and powder deaggregation. The best performing systems achieved EDs of 70-80% with fine particle fractions <5 μm of 65-85% and mass median aerodynamic diameters of 1.5 μm, which were target conditions for controlled condensational growth aerosol delivery. Decreasing the size of the flow control orifice from 3.6 to 2.3mm reduced the flow rate through the system with manual bag actuations from an average of 35 to 15LPM, while improving ED and aerosolization performance. The new devices can be applied to improve aerosol delivery during mechanical ventilation, nose-to-lung aerosol administration, and to assist patients that cannot reproducibly use passive DPIs. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. A whiff of death: fatal volatile solvent inhalation abuse.

    Science.gov (United States)

    Steffee, C H; Davis, G J; Nicol, K K

    1996-09-01

    Inhalation abuse of volatile solvents, previously known generically as "glue sniffing," is typically pursued by adolescents. A wide range of legal, easily obtained products containing volatile substances are available for abuse. We report two illustrative cases of fatal volatile substance abuse: gasoline sniffing in a 20-year-old man and aerosol propellant gas inhalation (aerosol air freshener) in a 16-year-old girl with underlying reactive airway disease. Although the ratio of deaths to nonfatal inhalation escapades is extremely low, volatile solvent abuse carries the risk of sudden death due to cardiac arrest after a dysrhythmia or vasovagal event, central nervous system respiratory depression, hypoxia and hypercapnia due to the techniques of inhalation, and other mechanisms. Investigation of the patient's substance abuse history, examination of the scene of death, and special toxicologic analyses are critical to identifying volatile substance inhalation abuse as the cause of death because anatomic autopsy findings will typically be nonspecific. Above all, physicians must suspect the diagnosis of volatile substance inhalation abuse, especially in any case of sudden death involving an otherwise healthy young person.

  19. Inhaled Antibiotic Therapy in Chronic Respiratory Diseases

    Directory of Open Access Journals (Sweden)

    Diego J. Maselli

    2017-05-01

    Full Text Available The management of patients with chronic respiratory diseases affected by difficult to treat infections has become a challenge in clinical practice. Conditions such as cystic fibrosis (CF and non-CF bronchiectasis require extensive treatment strategies to deal with multidrug resistant pathogens that include Pseudomonas aeruginosa, Methicillin-resistant Staphylococcus aureus, Burkholderia species and non-tuberculous Mycobacteria (NTM. These challenges prompted scientists to deliver antimicrobial agents through the pulmonary system by using inhaled, aerosolized or nebulized antibiotics. Subsequent research advances focused on the development of antibiotic agents able to achieve high tissue concentrations capable of reducing the bacterial load of difficult-to-treat organisms in hosts with chronic respiratory conditions. In this review, we focus on the evidence regarding the use of antibiotic therapies administered through the respiratory system via inhalation, nebulization or aerosolization, specifically in patients with chronic respiratory diseases that include CF, non-CF bronchiectasis and NTM. However, further research is required to address the potential benefits, mechanisms of action and applications of inhaled antibiotics for the management of difficult-to-treat infections in patients with chronic respiratory diseases.

  20. Retained Gas Sampler Calibration and Simulant Tests

    Energy Technology Data Exchange (ETDEWEB)

    CRAWFORD, B.A.

    2000-01-05

    This test plan provides a method for calibration of the retained gas sampler (RGS) for ammonia gas analysis. Simulant solutions of ammonium hydroxide at known concentrations will be diluted with isotopically labeled 0.04 M ammonium hydroxide solution. Sea sand solids will also be mixed with ammonium hydroxide solution and diluent to determine the accuracy of the system for ammonia gas analysis.

  1. A programmable air sampler with adsorption tubes

    International Nuclear Information System (INIS)

    Riesing, J.; Roetzer, H.; Hick, H.

    1997-01-01

    The Air Sampler AS3 was utilized for the European Tracer Experiment (ETEX) to measure the concentrations of the perfluorocarbon tracers. At thirty-two sampling points these devices were placed to collect the tracer substances in adsorption tubes for subsequent laboratory analysis in the Environment Institute of the JRC Ispra. The Air Sampler is also suitable for monitoring the environment, particularly of industrial emitters or landfills, by sampling of volatile substances. The Air Sampler AS3 is a portable, user-friendly instrument due to light weight, ruggedness and reliable operation. It is capable of fully automatic sampling of air and gas with 24 adsorption tubes and program-controlled gas flow. Collection times can be programmed freely between 1 sec and 8 days and waiting times between 1 sec and 30 days. Programming is possible via keyboard, memory card or serial interface. A protocol of sampling control data is stored on a memory card giving documentation of sampling conditions. On the memory card there is space for the storage of 10 sampling programs and 10 sets of sampling control data. Before the start of ETEX the AS3 was used in a measurement campaign to measure the background concentrations of the perfluorocarbon tracers in Austria. In the provinces of Upper Austria and Salzburg the Air Sampler is used by the departments for environmental protection for the monitoring of BTX-concentrations in air. (author)

  2. Quantum Gibbs Samplers: The Commuting Case

    Science.gov (United States)

    Kastoryano, Michael J.; Brandão, Fernando G. S. L.

    2016-06-01

    We analyze the problem of preparing quantum Gibbs states of lattice spin Hamiltonians with local and commuting terms on a quantum computer and in nature. Our central result is an equivalence between the behavior of correlations in the Gibbs state and the mixing time of the semigroup which drives the system to thermal equilibrium (the Gibbs sampler). We introduce a framework for analyzing the correlation and mixing properties of quantum Gibbs states and quantum Gibbs samplers, which is rooted in the theory of non-commutative {mathbb{L}_p} spaces. We consider two distinct classes of Gibbs samplers, one of them being the well-studied Davies generator modelling the dynamics of a system due to weak-coupling with a large Markovian environment. We show that their spectral gap is independent of system size if, and only if, a certain strong form of clustering of correlations holds in the Gibbs state. Therefore every Gibbs state of a commuting Hamiltonian that satisfies clustering of correlations in this strong sense can be prepared efficiently on a quantum computer. As concrete applications of our formalism, we show that for every one-dimensional lattice system, or for systems in lattices of any dimension at temperatures above a certain threshold, the Gibbs samplers of commuting Hamiltonians are always gapped, giving an efficient way of preparing the associated Gibbs states on a quantum computer.

  3. Retained Gas Sampler Calibration and Simulant Tests

    International Nuclear Information System (INIS)

    CRAWFORD, B.A.

    2000-01-01

    This test plan provides a method for calibration of the retained gas sampler (RGS) for ammonia gas analysis. Simulant solutions of ammonium hydroxide at known concentrations will be diluted with isotopically labeled 0.04 M ammonium hydroxide solution. Sea sand solids will also be mixed with ammonium hydroxide solution and diluent to determine the accuracy of the system for ammonia gas analysis

  4. Papers of the 15. french congress on the aerosols CFA 99; Actes du 15. congres francais sur les aerosols CFA 99

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This french congress on the aerosols took place in Paris the 8 and 9 december 1999. It was presented in four main themes: bio-aerosols and filtering; the aerosols metrology; the aerosols in the environment; aerosols physic and applications. Seven papers have been analyzed in INIS data base for their specific interest in nuclear industry. The four papers selected for ETDE cover a larger domain: annular slot samplers in turbulent flow, the air quality monitoring in France, suspension particles characterization in an urban area, application of the remote sensing to the atmospheric pollution. (A.L.B.)

  5. Objective measurement of inhaler inhalation flow profile using acoustic methods

    Energy Technology Data Exchange (ETDEWEB)

    Lacalle, H.; Taylor, T.E.; Marco, S.; Reilly, R.B.

    2016-07-01

    Patients with asthma and chronic obstructive pulmonary diseases (COPD) are mostly treated with inhalers that deliver medication directly to their airways. Drug delivery from dry powder inhalers (DPIs) is very much reliant on the inhalation manoeuvre, specifically the peak inspiratory flow rate (PIFR), inspiratory capacity (IC) and inhalation rise time (IRT) of the inhalation. It has been widely reported that patients may not follow correct inhalation technique while using their inhaler. In this study, a novel acoustic method is proposed to accurately estimate inhalation flow profile using only one inhalation recording for calibration. An Ellipta DPI was placed inside an airtight container with a spirometer connected in order to measure inhalation flow parameters. An acoustic recording device (Inhaler Compliance Assessment (INCA)) was also attached to the DPI. Inhalation audio and flow signals were recorded simultaneously. The data were collected from 20 healthy subjects while performing inhaler inhalations at a range of inspiratory flow rates. A power law regression model was computed to obtain the relationship between the acoustic envelope of the inhalation and flow profile of each recording. Each model was tested on the remaining audio signals to estimate flow profile. The average estimation error was found to be 10.5±0.3% for estimating flow profile from audio signals. Inhalation flow profile parameters (PIFR, IC and IRT) could then be measured from the estimated flow profile with high accuracy giving information on user inhalation technique. This method may assist in improving patient inhaler adherence and overall disease control. (Author)

  6. Inhaled antibiotics for lower airway infections.

    Science.gov (United States)

    Quon, Bradley S; Goss, Christopher H; Ramsey, Bonnie W

    2014-03-01

    Inhaled antibiotics have been used to treat chronic airway infections since the 1940s. The earliest experience with inhaled antibiotics involved aerosolizing antibiotics designed for parenteral administration. These formulations caused significant bronchial irritation due to added preservatives and nonphysiologic chemical composition. A major therapeutic advance took place in 1997, when tobramycin designed for inhalation was approved by the U.S. Food and Drug Administration (FDA) for use in patients with cystic fibrosis (CF) with chronic Pseudomonas aeruginosa infection. Attracted by the clinical benefits observed in CF and the availability of dry powder antibiotic formulations, there has been a growing interest in the use of inhaled antibiotics in other lower respiratory tract infections, such as non-CF bronchiectasis, ventilator-associated pneumonia, chronic obstructive pulmonary disease, mycobacterial disease, and in the post-lung transplant setting over the past decade. Antibiotics currently marketed for inhalation include nebulized and dry powder forms of tobramycin and colistin and nebulized aztreonam. Although both the U.S. Food and Drug Administration and European Medicines Agency have approved their use in CF, they have not been approved in other disease areas due to lack of supportive clinical trial evidence. Injectable formulations of gentamicin, tobramycin, amikacin, ceftazidime, and amphotericin are currently nebulized "off-label" to manage non-CF bronchiectasis, drug-resistant nontuberculous mycobacterial infections, ventilator-associated pneumonia, and post-transplant airway infections. Future inhaled antibiotic trials must focus on disease areas outside of CF with sample sizes large enough to evaluate clinically important endpoints such as exacerbations. Extrapolating from CF, the impact of eradicating organisms such as P. aeruginosa in non-CF bronchiectasis should also be evaluated.

  7. Note: Design and development of wireless controlled aerosol sampling network for large scale aerosol dispersion experiments

    International Nuclear Information System (INIS)

    Gopalakrishnan, V.; Subramanian, V.; Baskaran, R.; Venkatraman, B.

    2015-01-01

    Wireless based custom built aerosol sampling network is designed, developed, and implemented for environmental aerosol sampling. These aerosol sampling systems are used in field measurement campaign, in which sodium aerosol dispersion experiments have been conducted as a part of environmental impact studies related to sodium cooled fast reactor. The sampling network contains 40 aerosol sampling units and each contains custom built sampling head and the wireless control networking designed with Programmable System on Chip (PSoC™) and Xbee Pro RF modules. The base station control is designed using graphical programming language LabView. The sampling network is programmed to operate in a preset time and the running status of the samplers in the network is visualized from the base station. The system is developed in such a way that it can be used for any other environment sampling system deployed in wide area and uneven terrain where manual operation is difficult due to the requirement of simultaneous operation and status logging

  8. Note: Design and development of wireless controlled aerosol sampling network for large scale aerosol dispersion experiments

    Energy Technology Data Exchange (ETDEWEB)

    Gopalakrishnan, V.; Subramanian, V.; Baskaran, R.; Venkatraman, B. [Radiation Impact Assessment Section, Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam 603 102 (India)

    2015-07-15

    Wireless based custom built aerosol sampling network is designed, developed, and implemented for environmental aerosol sampling. These aerosol sampling systems are used in field measurement campaign, in which sodium aerosol dispersion experiments have been conducted as a part of environmental impact studies related to sodium cooled fast reactor. The sampling network contains 40 aerosol sampling units and each contains custom built sampling head and the wireless control networking designed with Programmable System on Chip (PSoC™) and Xbee Pro RF modules. The base station control is designed using graphical programming language LabView. The sampling network is programmed to operate in a preset time and the running status of the samplers in the network is visualized from the base station. The system is developed in such a way that it can be used for any other environment sampling system deployed in wide area and uneven terrain where manual operation is difficult due to the requirement of simultaneous operation and status logging.

  9. Administration of cyclosporine by inhalation: A feasibility study in Beagle dogs

    International Nuclear Information System (INIS)

    Muggenburg, B.A.; Hoover, M.D.; Haley, P.J.; Snipes, M.B.; Wolff, R.K.; Yeh, H.C.; Griffith, B.P.; Burckart, J.; Mauderly, J.L.

    1988-01-01

    Oral cyclosporine inhibits the primary,but-not the secondary immune responses in the lung. These findings suggest that the local administration of cyclosporine by inhalation could be a useful tool for increasing our understanding of lung immunity. Five dogs were each treated with inhaled, oral and intravenous cyclosporine, aerosol vehicle (ethyl alcohol), and no treatment, over a 5-wk period. One treatment per week was given to each dog. A radiolabel, 99m Tc was included in the cyclosporine aerosol to allow visualization of lung distribution of the aerosol. Blood plasma concentrations of cyclosporine were approximately the same at 4 h and were essentially cleared by 24 h for all routes of administration. Aerosol distribution in the lung appeared uniform, based on 99m Tc scintigrams. In a second study, two dogs inhaled cyclosporine once a day for five days, two dogs inhaled the aerosol vehicle, and one dog was not treated. No evidence of acute lung injury, based on cell counts, total protein, alkaline phosphatase, or lactic dehydrogenase levels in the bronchoalveolar lavage fluid, was found at 24 h after one or five administrations of cyclosporine. These data indicate that cyclosporine administered by aerosol either once or five times was distributed throughout the lung and was absorbed into the blood without producing an acute inflammatory reaction in the lung. Our results suggest that cyclosporine may be safely given by inhalation for studies of local immune responses in the lung. (author)

  10. The History of Therapeutic Aerosols: A Chronological Review.

    Science.gov (United States)

    Stein, Stephen W; Thiel, Charles G

    2017-02-01

    In 1956, Riker Laboratories, Inc., (now 3 M Drug Delivery Systems) introduced the first pressurized metered dose inhaler (MDI). In many respects, the introduction of the MDI marked the beginning of the modern pharmaceutical aerosol industry. The MDI was the first truly portable and convenient inhaler that effectively delivered drug to the lung and quickly gained widespread acceptance. Since 1956, the pharmaceutical aerosol industry has experienced dramatic growth. The signing of the Montreal Protocol in 1987 led to a surge in innovation that resulted in the diversification of inhaler technologies with significantly enhanced delivery efficiency, including modern MDIs, dry powder inhalers, and nebulizer systems. The innovative inhalers and drugs discovered by the pharmaceutical aerosol industry, particularly since 1956, have improved the quality of life of literally hundreds of millions of people. Yet, the delivery of therapeutic aerosols has a surprisingly rich history dating back more than 3500 years to ancient Egypt. The delivery of atropine and related compounds has been a crucial inhalation therapy throughout this period and the delivery of associated structural analogs remains an important therapy today. Over the centuries, discoveries from many cultures have advanced the delivery of therapeutic aerosols. For thousands of years, therapeutic aerosols were prepared by the patient or a physician with direct oversight of the patient using custom-made delivery systems. However, starting with the Industrial Revolution, advancements in manufacturing resulted in the bulk production of therapeutic aerosol delivery systems produced by people completely disconnected from contact with the patient. This trend continued and accelerated in the 20th century with the mass commercialization of modern pharmaceutical inhaler products. In this article, we will provide a summary of therapeutic aerosol delivery from ancient times to the present along with a look to the future. We

  11. Two years of aerosol pollution monitoring in Singapore: a review

    International Nuclear Information System (INIS)

    Orlic, I.; Wen, X.; Ng, T.H.; Tang, S.M.

    1999-01-01

    An aerosol sampling campaign was initiated more than two years ago in Singapore. The aim was to determine the average elemental concentrations in fine and coarse aerosol fractions as well as to identify major pollution sources and their impact. For that purpose, two air samplers were employed at two different sampling locations; one sampler was a fine particulate aerosol sampler (PM2.5) located at the vicinity of a major industrial area. The other was a stacked filter unit (SFU) sampler designed for collection of fine and coarse fractions (PM2.5 and PM10) and installed in the residential area. Samples were taken typically twice a week and in several occasions daily. During the period of two years more than 700 aerosol samples were collected and analyzed using PIXE and RBS techniques. All samples were analyzed for 18 elements ranging between Na, Mg, Al, etc. up to As and Pb. Large daily and seasonal variations were found for most of the elements. These variations are attributed mainly to meteorological changes, in particular changes in wind speed and direction. On several occasions, short term sampling was performed to identify fingerprints of major pollution sources such as road traffic, refineries, as well as the rain-forest fires in neighboring countries. A summary of our findings is presented and discussed

  12. Onshore Wind Speed Modulates Microbial Aerosols along an Urban Waterfront

    Directory of Open Access Journals (Sweden)

    M. Elias Dueker

    2017-11-01

    Full Text Available Wind blowing over aquatic and terrestrial surfaces produces aerosols, which include microbial aerosols. We studied the effect of onshore wind speeds on aerosol concentrations as well as total and culturable microbial aerosols (bacterial and viral at an urban waterfront (New York, NY, United States of America. We used two distinct methods to characterize microbial aerosol responses to wind speed: A culture-based exposure-plate method measuring viable bacterial deposition near-shore (CFU accumulation rate; and a culture-independent aerosol sampler-based method measuring total bacterial and viral aerosols (cells m−3 air. While ambient coarse (>2 µm and fine (0.3–2 µm aerosol particle number concentrations (regulated indicators of air quality decreased with increasing onshore wind speeds, total and depositing culturable bacterial aerosols and total viral aerosols increased. Taxonomic identification of the 16S rDNA of bacterial aerosol isolates suggested both terrestrial and aquatic sources. Wind appears to increase microbial aerosol number concentrations in the near-shore environment by onshore transport at low wind speeds (<4 m s−1, and increased local production and transport of new microbial aerosols from adjacent water surfaces at higher wind speeds (>4 m s−1. This study demonstrates a wind-modulated microbial connection between water and air in the coastal urban environment, with implications for public health management and urban microbial ecology.

  13. Inhalation Toxicology Research Institute annual report, October 1, 1982-September 30, 1983

    International Nuclear Information System (INIS)

    1983-12-01

    The mission of the Inhalation Toxicology Research Institute (ITRI) is to investigate the nature and magnitude of human health effects that might result from inhalation of airborne materials encountered in the work place, special attention is directed toward airborne particulate and gaseous emissions released by various energy technologies or from national defense activities. Included are five papers on the physical and chemical characterization of energy technology aerosols, 10 papers on laboratory studies of aerosol generation and characterization, 11 papers on in vitro predictors of toxicity, 12 papers on disposition and fate of inhaled materials, 24 papers on dose-response relationships for inhaled radionuclides, 3 papers on dose-response relationships for inhaled chemical toxicants, 8 papers on biological factors that influence dose-response relationships, and 4 papers are concerned with risk assessment

  14. Inhalant abuse of computer cleaner manifested as angioedema.

    Science.gov (United States)

    Kurniali, Peter C; Henry, Letitia; Kurl, Rita; Meharg, Joseph V

    2012-01-01

    Inhalant abuse is the intentional inhalation of chemical vapors or volatile substance to achieve a euphoric effect. Although no statistical data are reported yet, inhalant abuse is potentially life-threatening and has resulted in a wide range of toxic effects such as central nervous system depression, seizures, aspiration, cardiac arrhythmia, asphyxiation, hypoxia, metabolic acidosis, and sudden death among others. We are reporting a 25-year-old white man who was brought to the emergency department after inhaling aerosolized computer-cleaning spray composed of difluoroethane. He was found to have marked upper and lower lip facial swelling consistent with angioedema. The patient also had a prolonged QT interval, mild inspiratory stridor, but no urticaria. In this case, we believe the difluoroethane-related angioedema represents either idiopathic or bradykinin-induced angioedema.

  15. Influence of inhaled Ca-DTPA on the long-term effects of inhaled Pu nitrate

    International Nuclear Information System (INIS)

    Ballou, J.E.; Dagle, G.E.; McDonald, K.E.; Buschbom, R.L.

    1975-01-01

    Inhaled Ca-DTPA administered to rats in 6 weekly, one-hour treatments of 3 mg/rat did not affect weight gain or life-span compared to Pu burdened animals (78 nCi ILB) or nontreated controls. In addition, the drug did not appear to promote the development of malignant lung tumors and bone tumors in Pu burdened rats although one rat exposed only to Ca-DTPA aerosols did develop a malignant lung tumor. This single lung tumor can not be considered significant although the normal incidence of this lesion is quite low. Inhaled Ca-DTPA therapy administered 20 days after Pu inhalation showed little effect in reducing the lung burden of plutonium. Skeletal deposition was decreased possibly because Ca-DTPA was administered during a time of active translocation of the inhaled Pu when Pu may have been available for chelation in the blood. Inhaled Ca-DTPA therapy did not appear to be beneficial in reducing the number of malignant lung tumors or bone tumors in plutonium burdened rats but on the other hand the chelate did not appear to promote these lesions. (U.S.)

  16. Performance improvements on passive activated charcoal 222Rn samplers

    International Nuclear Information System (INIS)

    Wei Suxia

    1996-01-01

    Improvements have been made on passive activated charcoal 222 Rn samplers with sintered metal filters. Based on the samplers of good adaptability to temperature and humidity developed before, better charcoal was selected to further improve their performance in radon absorption ability and moisture-resistance. And charcoal quantity in samplers was strictly controlled. The integration time constant of the improved samplers was about 4.3 days. As the sampler was combined with gamma spectrometer to measure radon concentration, the calibration factor was 0.518 min -1 ·Bq -1 ·m 3 for samplers of 7 days exposure time, and the minimum detectable concentration 0.28 Bq·m -3 if counting time for both background and sample is 1000 minutes. The improved samplers are suited to accurately determine the indoor and outdoor average radon concentration under conditions of great variation in temperature and humidity

  17. Inhaled Antibiotics for Ventilator-Associated Infections.

    Science.gov (United States)

    Palmer, Lucy B

    2017-09-01

    Multidrug-resistant organisms are creating a challenge for physicians treating the critically ill. As new antibiotics lag behind the emergence of worsening resistance, intensivists in countries with high rates of extensively drug-resistant bacteria are turning to inhaled antibiotics as adjunctive therapy. These drugs can provide high concentrations of drug in the lung that could not be achieved with intravenous antibiotics without significant systemic toxicity. This article summarizes current evidence describing the use of inhaled antibiotics for the treatment of bacterial ventilator-associated pneumonia and ventilator-associated tracheobronchitis. Preliminary data suggest aerosolized antimicrobials may effectively treat resistant pathogens with high minimum inhibitory concentrations. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Inhalants in Peru.

    Science.gov (United States)

    Lerner, R; Ferrando, D

    1995-01-01

    In Peru, the prevalence and consequences of inhalant abuse appear to be low in the general population and high among marginalized children. Inhalant use ranks third in lifetime prevalence after alcohol and tobacco. Most of the use appears to be infrequent. Among marginalized children, that is, children working in the streets but living at home or children living in the street, the problem of inhalant abuse is a serious problem. Among children working in the streets but living at home, the lifetime prevalence rate for inhalant abuse is high, ranging from 15 to 45 percent depending on the study being cited. For children living in the streets, the use of inhalant is even more severe. As mentioned earlier in this chapter, most of these street children use inhalants on a daily basis. The lack of research on the problem of inhalant abuse is a serious impediment to development of intervention programs and strategies to address this problem in Peru. Epidemiologic and ethnographic research on the nature and extent of inhalant abuse are obvious prerequisites to targeted treatment and preventive intervention programs. The urgent need for current and valid data is underscored by the unique vulnerability of the youthful population at risk and the undisputed harm that results from chronic abuse of inhalants. Nonetheless, it is important to mention several programs that work with street children. Some, such as the Information and Education Center for the Prevention of Drug Abuse, Generation, and Centro Integracion de Menores en Abandono have shelters where street children are offered transition to a less marginal lifestyle. Teams of street educators provide the children with practical solutions and gain their confidence, as well as offer them alternative socialization experiences to help them survive the streets and avoid the often repressive and counterproductive environments typical of many institutions. Most of the children who go through these programs tend to abandon

  19. Radiation dose estimates and hazard evaluations for inhaled airborne radionuclides: Final report

    International Nuclear Information System (INIS)

    Mewhinney, J.A.

    1987-09-01

    The project objective was to conduct confirmatory research on physical chemical characteristics of aerosols produced during manufacture of mixed plutonium and uranium oxide nuclear fuel, to determine the radiation dose distribution in tissues of animals after inhalation exposure to representative aerosols of these materials, and to provide estimates of the relationship of radiation dose and biological response in animals after such inhalation exposure. The first chapter summarizes the physical chemical characterization of samples of aerosols collected from gloveboxes at industrial facilities during normal operations. This chapter provides insights into key aerosol characteristics which are of potential importance in determining the biological fate of specific radionuclides contained in the particulates that would be inhaled by humans following accidental release. The second chapter describes the spatial and temporal distribution of radiation dose in tissues of three species of animals exposed to representative aerosols collected from the industrial facilities. These inhalation studies provide a basis for comparison of the influence of physical chemical form of the inhaled particulates and the variability among species of animal in the radiation dose to tissue. The third chapter details to relationship between radiation dose and biological response in rats exposed to two aerosol forms each at three levels of initial pulmonary burden. This study, conducted over the lifespan of the rats and assuming results to be applicable to humans, indicates that the hazard to health due to inhalation of these industrial aerosols is not different than previously determined for laboratory produced aerosol of PuO 2 . Each chapter is processed separately for the data base

  20. Lung dosimetry for inhaled radon progeny

    International Nuclear Information System (INIS)

    Hofmann, W.

    1986-01-01

    Lung cancer risk assessment for inhaled radon progeny requires a detailed knowledge of the dose distribution pattern throughout the human respiratory tract. Current lung dosimetry models take into acocunt aerosol deposition in a formalized airway structrue, modification of the initial deposition pattern by clearance mechanisms, and the energy deposited by alpha particles in sensitive cells of the bronchial epithelium. The resulting dose distribution pattern depends on the characteristics of the inhaled aerosol and the breathing pattern. Special emphasis has been laid on the age dependency of the anatomical structure of the human lung and the resulting doses, as well as on the rediological significance of enhanced aerosol deposition at bronchial bifuraction. The biological variability inherent in all morphometric, physiological and histological parameters involved in lung dosimetry suggests the application of stochastic modelling techniques. Examples for the use of Monte Carlo methods presented here are the random walk of inhaled particles through a random airway geometry, and the influence of the intra-subject variability of radiation doses on radiation protection standards. At the cellular level the concept of absorbed dose loses its significance and has to be replaced by microdosimetric concepts, such as internal microdosimtry or track structure theory. An image-analysis model allows us to construct specific energy distributions in sensitive lung cells. Application of a track structure model of alpha particle interaction with bronchial epithelial cells permits the calculation of probabilities for inactivation, transformation, and tumor induction. The latter has been used to analyse lung cancer risk at low doses in Chinese high background areas

  1. Advance in research on aerosol deposition simulation methods

    International Nuclear Information System (INIS)

    Liu Keyang; Li Jingsong

    2011-01-01

    A comprehensive analysis of the health effects of inhaled toxic aerosols requires exact data on airway deposition. A knowledge of the effect of inhaled drugs is essential to the optimization of aerosol drug delivery. Sophisticated analytical deposition models can be used for the computation of total, regional and generation specific deposition efficiencies. The continuously enhancing computer seem to allow us to study the particle transport and deposition in more and more realistic airway geometries with the help of computational fluid dynamics (CFD) simulation method. In this article, the trends in aerosol deposition models and lung models, and the methods for achievement of deposition simulations are also reviewed. (authors)

  2. Model for deposition and long-term disposition of 134Cs-labeled fused aluminosilicate particles inhaled by guinea pigs

    International Nuclear Information System (INIS)

    Snipes, M.B.; McClellan, R.O.

    1986-01-01

    When considering which laboratory animal species to use in inhalation studies, it is important to evaluate the similarities and differences in deposition and fate of the inhaled materials in various laboratory animals compared with humans. Beagle dogs have deposition and clearance patterns of inhaled particles similar to humans. However, some studies require smaller laboratory animals to be cost effective or to allow an adequate number of animals to address the scientific questions. This study evaluated the deposition and clearance of a relatively insoluble aerosol inhaled by guinea pigs. The test aerosol was monodisperse 134 Cs-labeled fused aluminosilicate particles inhaled during 75 minute inhalation exposure. The guinea pigs had deposition similar to rats but respiratory tract retention and clearance patterns were similar to dogs and humans. 5 references, 2 figures, 1 table

  3. Heavy water leak detection using diffusion sampler

    International Nuclear Information System (INIS)

    Joshi, M.L.; Hussain, S.A.

    1990-01-01

    In the Pressurrised Heavy Water Reactors (PHWRs) detection of the sources of heavy water leaks is importent both for the purpose of radiation hazard control as well as for the reduction of escape/loss of heavy water which, is an expensive nuclear material. This paper describes an application of tritium diffusion sampler for heavy water leak detection. The diffusion sampler comprises an usual tritium counting glass vial with a special orifice. The counting vial has water vapour, deficient in HTO concentration. The HTO present outside diffuses in the vial through the orifice, gets exchanged with water of the wet filter paper kept at the bottom and the moisture in the vial atmosphere which has HTO concentration lower than that outside. This results in continuation of net movement of HTO in the vial. The exchanged tritium is counted in liquid scintillation spectrometer. The method has a sensitivity of 10000 dpm/DAC-h. (author). 2 figs., 2 ta bs

  4. CAM and stack air sampler design guide

    International Nuclear Information System (INIS)

    Phillips, T.D.

    1994-01-01

    About 128 air samplers and CAMs presently in service to detect and document potential radioactive release from 'H' and 'F' area tank farm ventilation stacks are scheduled for replacement and/or upgrade by Projects S-5764, S-2081, S-3603, and S-4516. The seven CAMs scheduled to be upgraded by Project S-4516 during 1995 are expected to provide valuable experience for the three remaining projects. The attached document provides design guidance for the standardized High Level Waste air sampling system

  5. Inhalative cadmium effects in pregnant and fetal rats

    Energy Technology Data Exchange (ETDEWEB)

    Prigge, E.

    1978-01-01

    Pregnant and non-pregnant rats were continuously exposed for 21 days to an aerosol containing 0.2, 0.4, and 0.6 mg cadmium/m/sup 3/ air. Pregnant and non-pregnant rats exposed to clean air served as controls. The aerosol was generated by an ultrasonic nebulizer and was carried into inhalation chambers. The median aerodynamic diameters were on the order of 0.6 ..mu..m. After inhalation of cadmium aerosols, serum iron levels were not lowered significantly in adult rats. A polycythaemic response of non-pregnant rats was observed due to a direct stimulatory effect of cadmium on erythropoiesis. Polycythaemia was less marked in pregnancy, presumably due to iron loss to placenta and fetus. Disturbances of pulmonary gas exchange or decreased plasma volumes were excluded as causative mechanisms of polycythaemia. In pregnant rats there was a marked dose dependent decrease of the activity of the alkaline phosphatase after cadmium inhalation, while there was no effect in exposed non-pregnant rats. This decreased enzyme activity, together with slowed growth rates and hemolytic effect indicate a higher sensitivity to cadmium in pregnancy. Proteinuria was not found in neither pregnant nor non-pregnant rats. Therefore, it is concluded that in this respect cadmium intoxication by inhalation does not resemble human toxemia of pregnancy, as discussed in the literature.

  6. Evaluation of the Respimat Soft Mist Inhaler using a concurrent CFD and in vitro approach.

    Science.gov (United States)

    Worth Longest, P; Hindle, Michael

    2009-06-01

    The Respimat Soft Mist Inhaler is reported to generate an aerosol with low spray momentum and a small droplet size. However, the transport characteristics of the Respimat aerosol are not well understood. The objective of this study was to characterize the transport and deposition of an aerosol emitted from the Respimat inhaler using a combination of computational fluid dynamics (CFD) modeling and in vitro experiments. Deposition of the Respimat aerosol was assessed in the inhaler mouthpiece (MP), a standard induction port (IP), and a more realistic mouth-throat (MT) geometry at an inhalation flow rate of 30 L/min. Aerosols were generated using an albuterol sulfate (0.6%) solution, and the drug deposition was quantified using both in vitro experiments and a CFD model of the Respimat inhaler. Laser diffraction experiments were used to determine the initial polydisperse aerosol size distribution. It was found that the aerosol generated from the highly complex process of jet collision and breakup could be approximated in the model using effective spray conditions. Computational predictions of deposition fractions agreed well with in vitro results for both the IP (within 20% error) and MT (within 10% error) geometries. The experimental results indicated that the deposition fraction of drug in the MP ranged from 27 to 29% and accounted for a majority of total drug loss. Based on the CFD solution, high MP deposition was due to a recirculating flow pattern that surrounded the aerosol spray and entrained a significant number of small droplets. In contrast, deposition of the Respimat aerosol in both the IP (4.2%) and MT (7.4%) geometries was relatively low. Results of this study indicate that modifications to the current Respimat MP and control of specific patient variables may significantly reduce deposition in the device and may decrease high oropharyngeal drug loss observed in vivo.

  7. Environmental HTO/HT sampler development

    International Nuclear Information System (INIS)

    Workman, W.J.G.; Brown, R.M.; Wood, M.J.

    1994-01-01

    Tests of retention by several drying agents of HTO from an air stream containing HT have been performed. Two batches of Molecular Sieve (MS) 4A retained up to 1.3% of HT passed through them, in contrast to material tested in 1986, when retention was -4 . Retention of 10 -5 to 10 -6 was observed for DRIERITE (anhydrous calcium sulphate) and Silica Gel. DRIERITE is preferred over Silica Gel as a desiccant in an air sampler for environmental HTO/HT, because it is much easier to decontaminate for reuse. An improved air sampler has been designed, 2 units constructed and components procured for 3 more. The air sampler may be line or battery operated, accommodates up to four 120 g drier or oxidizer traps, and will pump up to 4 L/min for up to 24 hours on battery power. It is built into a rugged aluminum case and weighs approximately 11 kg overall, facilitating deployment in the field. (author). 5 refs., 2 tabs., 4 figs

  8. Half-liter supernatant sampler system engineering work plan

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1995-01-01

    The Tank Waste Remediation System (TWRS) pretreatment facility project W-236B, known as the Initial Pretreatment Module (IPM), requires samples of supernatants and sludges from 200 Area tank farms for planned hot testing work in support of IPM design. The IPM project has proposed the development of several new sampler systems. These systems include a 0.5-l supernatant sampler, 3-l and 25-l supernatant and sludge samplers, and a 4,000-l sampler system. The 0.5-l sampler will support IPM sampling needs in the 1 to 3 l range starting in late fiscal year 1995. This sampler is intended to be used in conjunction with the existing 100 ml bottle-on-a-string. The 3-l and 25-l systems will be based on the Savannah River Site's sampler system and will support IPM sampling needs in the 3 to 100 liter range. Most of the hot testing required for design of the IPM must be accomplished in the next 3 years. This work plan defines the tasks associated with the development of a 0.5-l sampler system. This system will be referred to as the Half-Liter Supernatant Sampler System (HLSSS). Specifically, this work plan will define the scope of work, identify organizational responsibilities, identify major technical requirements, describe configuration control and verification requirements, and provide estimated costs and schedule. The sampler system will be fully operational, including trained staff and operating procedures, upon completion of this task

  9. Aerosol particle size does not predict pharmacokinetic determined lung dose in children

    DEFF Research Database (Denmark)

    Bønnelykke, Klaus; Chawes, Bo L K; Vindfeld, Signe

    2013-01-01

    In vitro measures of aerosol particles size, such as the fine particle mass, play a pivotal role for approval of inhaled anti-asthmatic drugs. However, the validity as a measure of dose to the lungs in children lacks evidence. In this study we investigated for the first time the association between...... an in vivo estimate of lung dose of inhaled drug in children and the corresponding particle size segments assessed ex vivo. Lung dose of fluticasone propionate after inhalation from a dry powder inhaler (Diskus®) was studied in 23 children aged 4-7 and 12-15 years with mild asthma. Six-hour pharmacokinetics...... was assessed after single inhalation. The corresponding emitted mass of drug in segments of aerosol particle size was assessed ex vivo by replicating the inhalation flows recorded by transducers built into the Diskus® inhaler and re-playing them in a breathing simulator. There was no correlation between any...

  10. Accidental Cutaneous Burns Secondary to Salbutamol Metered Dose Inhaler

    Directory of Open Access Journals (Sweden)

    Ashutosh Kale

    2010-01-01

    Full Text Available We report a case of accidental cutaneous burns caused by salbutamol metered dose inhaler. A 9-year-old boy underwent dental extraction at a children's hospital and was incidentally noted to have burn injuries on dorsum of both hands. On questioning, the boy revealed that a few days ago his 14-year-old brother, who is an asthmatic, playfully sprayed his salbutamol metered dose inhaler on the back of both his hands with the inhaler's mouth piece being in direct contact with the patient's skin. On examination, there was a rectangular area of erythema with superficial peeling on the dorsum of both hands, the dimensions of which exactly matched those of the inhaler's mouthpiece. It is possible that the injury could have been a chemical burn from the pharmaceutical/preservative/propellant aerosol or due to the physical effect of severe cooling of the skin or mechanical abrasive effect of the aerosol blasts or a combination of some or all the above mechanisms. This case highlights the importance of informing children and parents of the potentially hazardous consequences of misusing a metered dose inhaler.

  11. Organic aerosols

    International Nuclear Information System (INIS)

    Penner, J.E.

    1994-01-01

    Organic aerosols scatter solar radiation. They may also either enhance or decrease concentrations of cloud condensation nuclei. This paper summarizes observed concentrations of aerosols in remote continental and marine locations and provides estimates for the sources of organic aerosol matter. The anthropogenic sources of organic aerosols may be as large as the anthropogenic sources of sulfate aerosols, implying a similar magnitude of direct forcing of climate. The source estimates are highly uncertain and subject to revision in the future. A slow secondary source of organic aerosols of unknown origin may contribute to the observed oceanic concentrations. The role of organic aerosols acting as cloud condensation nuclei (CCN) is described and it is concluded that they may either enhance or decrease the ability of anthropogenic sulfate aerosols to act as CCN

  12. FACTORS AFFECTING THE DEPOSITION OF AEROSOLIZED INSULIN

    Science.gov (United States)

    AbstractBackground The inhalation of insulin for absorption into the bloodstream via the lung seems to be a promising technique for the treatment of diabetes mellitus. A fundamental issue to be resolved in the development of such insulin aerosol delivery systems is their...

  13. Internal dosimetric evaluation due to uranium aerosols

    International Nuclear Information System (INIS)

    Garcia Aguilar Juan; Delgado Avila Gustavo

    1991-01-01

    The present work has like object to carry out the internal dosimetric evaluation to the occupationally exposed personnel, due to the inhalation of aerosols of natural uranium and enriched in the pilot plant of nuclear fuel production of the National Institute of Nuclear Research

  14. Fate of inhaled azodicarbonamide in rats

    International Nuclear Information System (INIS)

    Mewhinney, J.A.; Ayres, P.H.; Bechtold, W.E.; Dutcher, J.S.; Cheng, Y.S.; Bond, J.A.; Medinsky, M.A.; Henderson, R.F.; Birnbaum, L.S.

    1987-01-01

    Azodicarbonamide (ADA) is widely used as a blowing agent in the manufacture of expanded foam plastics, as an aging and bleaching agent in flour, and as a bread dough conditioner. Human exposures have been reported during manufacture as well as during use. Groups of male F344/N rats were administered ADA by gavage, by intratracheal instillation, and by inhalation exposure to determine the disposition and modes of excretion of ADA and its metabolites. At 72 hr following gavage, 30% of the administered ADA was absorbed whereas following intratracheal instillation, absorption was 90%. Comparison between groups of rats exposed by inhalation to ADA to achieve body burdens of 24 or 1230 micrograms showed no significant differences in modes or rates of excretion of [ 14 C]ADA equivalents. ADA was readily converted to biurea under physiological conditions and biurea was the only 14 C-labeled compound present in excreta. [ 14 C]ADA equivalents were present in all examined tissues immediately after inhalation exposure, and clearance half-times on the order of 1 day were evident for all tissues investigated. Storage depots for [ 14 C]ADA equivalents were not observed. The rate of buildup of [ 14 C]ADA equivalents in blood was linearly related to the lung content as measured from rats withdrawn at selected times during a 6-hr inhalation exposure at an aerosol concentration of 25 micrograms ADA/liter. In a study extending 102 days after exposure, retention of [ 14 C]ADA equivalents in tissues was described by a two-component negative exponential function. The results from this study indicate that upon inhalation, ADA is rapidly converted to biurea and that biurea is then eliminated rapidly from all tissues with the majority of the elimination via the urine

  15. Puffing and inhalation behaviour in cigarette smoking: Implications for particle diameter and dose

    Energy Technology Data Exchange (ETDEWEB)

    Dickens, Colin; McGrath, Conor; Warren, Nigel; Biggs, Philip; McAughey, John, E-mail: colin_dickens@bat.co [British American Tobacco, Group R and D Centre, Southampton, SO15 8TL (United Kingdom)

    2009-02-01

    Inhalation of tobacco smoke aerosol is a two-step process involving puffing followed by inhalation. Measured smoke deposition efficiencies in the lung (20-70%) are greater than expected for smoke particles of diameter 150 - 250 nm CMD. Various mechanisms have been put forward to explain this enhanced deposition pattern, including coagulation, hygroscopic growth, condensation and evaporation, changes in composition, or changes in inhalation behaviour. This paper represents one of a series of studies seeking to better quantify smoke chemistry, inhalation behaviour and cumulative particle growth. The studies have been conducted to better understand smoke dosimetry and links to disease as part of a wider programme defining risk and potential harm reduction. In this study, it was noted that particle deposition increased with increasing inhalation depth, and that smoke inhalation volumes were generally greater than normal tidal breathing volumes. A weak association was observed between particle diameter and puff flow, but no strong association between particle diameter and retention efficiency.

  16. Puffing and inhalation behaviour in cigarette smoking: Implications for particle diameter and dose

    International Nuclear Information System (INIS)

    Dickens, Colin; McGrath, Conor; Warren, Nigel; Biggs, Philip; McAughey, John

    2009-01-01

    Inhalation of tobacco smoke aerosol is a two-step process involving puffing followed by inhalation. Measured smoke deposition efficiencies in the lung (20-70%) are greater than expected for smoke particles of diameter 150 - 250 nm CMD. Various mechanisms have been put forward to explain this enhanced deposition pattern, including coagulation, hygroscopic growth, condensation and evaporation, changes in composition, or changes in inhalation behaviour. This paper represents one of a series of studies seeking to better quantify smoke chemistry, inhalation behaviour and cumulative particle growth. The studies have been conducted to better understand smoke dosimetry and links to disease as part of a wider programme defining risk and potential harm reduction. In this study, it was noted that particle deposition increased with increasing inhalation depth, and that smoke inhalation volumes were generally greater than normal tidal breathing volumes. A weak association was observed between particle diameter and puff flow, but no strong association between particle diameter and retention efficiency.

  17. Radioactive aerosols

    International Nuclear Information System (INIS)

    Chamberlain, A.C.

    1991-01-01

    Radon. Fission product aerosols. Radioiodine. Tritium. Plutonium. Mass transfer of radioactive vapours and aerosols. Studies with radioactive particles and human subjects. Index. This paper explores the environmental and health aspects of radioactive aerosols. Covers radioactive nuclides of potential concern to public health and applications to the study of boundary layer transport. Contains bibliographic references. Suitable for environmental chemistry collections in academic and research libraries

  18. Olodaterol Oral Inhalation

    Science.gov (United States)

    ... in a class of medications called long-acting beta-agonists (LABAs). It works by relaxing and opening ... the inhaler upright with the yellow cap closed. Turn the clear base in the direction of the ...

  19. Pirbuterol Acetate Oral Inhalation

    Science.gov (United States)

    ... Pirbuterol is in a class of medications called beta-agonist bronchodilators. It works by relaxing and opening ... cleaning. Once a week, remove the mouthpiece cover, turn the inhaler upside down and wipe the mouthpiece ...

  20. Cromolyn Oral Inhalation

    Science.gov (United States)

    ... your doctor.Cromolyn oral inhalation helps to prevent asthma attacks (sudden episodes of shortness of breath, wheezing, and coughing) but will not stop an asthma attack that has already started. Your doctor will prescribe ...

  1. Ipratropium Oral Inhalation

    Science.gov (United States)

    ... with the clear end pointing upward. Place the metal canister inside the clear end of the inhaler. ... do not discard it in an incinerator or fire.Unneeded medications should be disposed of in special ...

  2. Nicotine Oral Inhalation

    Science.gov (United States)

    ... with a smoking cessation program, which may include support groups, counseling, or specific behavioral change techniques. Nicotine inhalation ... and pharmacist what prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking or ...

  3. Toxicity of inhaled alpha-emitting radionuclides - Status report

    International Nuclear Information System (INIS)

    Muggenburg, B.A.; Mewhinney, J.A.; Guilmette, R.A.; Gillett, N.A.; Diel, J.H.; Lundgren, D.L.; Hahn, F.F.; Boecker, B.B.; McClellan, R.O.

    1988-01-01

    The toxicity of inhaled alpha-emitting radionuclides is being investigated in a series of interrelated dose-response studies. Dogs, rodents, and nonhuman primates have been exposed to monodisperse or polydisperse aerosols of the oxides of 239 Pu, 238 Pu, 241 Am, or 244 Cm to measure the relative importance of average organ dose, local dose around particles, specific activity, chemical form, particle size, and number of particles inhaled to the development of biological effects. The influence of animal species, age at exposure, and pre-existing lung disease, as well as the effects of repeated exposure, are also being studied, because they may influence the toxicity of these radionuclides. (author)

  4. Particle-size dependent effects in the Balb/c murine model of inhalational melioidosis

    Directory of Open Access Journals (Sweden)

    Richard eThomas

    2012-07-01

    Full Text Available Deposition of Burkholderia pseudomallei within either the lungs or nasal passages of the Balb/c murine model resulted in different infection kinetics. The infection resulting from the inhalation of B. pseudomallei within a 12 um particle aerosol was prolonged compared to a 1 um particle aerosol with a mean time-to-death (MTD of 73.8 ± 11.3 h and 174.7 ± 14.9 h respectively. Inhalation of B. pseudomallei within 1 um or 12 um particle aerosols resulted in a median lethal dose (MLD of 4 and 12 cfu respectively. The 12 mm particle inhalational infection was characterised by involvement of the respiratory epithelium and inflammation of the neurological path leading from the olfactory epithelium to the olfactory bulb (100%, culminating in abscessation of the brain (33%. Initial involvement of the upper respiratory tract lymphoid tissues (nasal-associated lymphoid tissue and cervical lymph nodes was observed in both the 1 and 12 um particle inhalational infections (80-85%. Necrotising alveolitis and bronchiolitis were evident in both inhalational infections however lung pathology was greater after inhalation of the 1 mm particle aerosol with pronounced involvement of the mediastinal lymph node (50%. Terminal disease was characterised by bacteraemia in both inhalational infections with dissemination to the spleen, liver, kidneys and thymus. Treatment with co-trimoxazole was more effective than treatment with doxycycline irrespective of the size of the particles inhaled. Doxycycline was more effective against the 12 um particle inhalational infection as evidenced by increased time to death. However, both treatment regimes exhibited significant relapse when therapy was discontinued with massive enlargement and abscessation of the lungs, spleen and cervical lymph nodes observed.

  5. Aerosol Chemical Composition and its Effects on Cloud-Aerosol Interactions during the 2007 CHAPS Experiment

    Science.gov (United States)

    Lee, Y.; Alexander, L.; Newburn, M.; Jayne, J.; Hubbe, J.; Springston, S.; Senum, G.; Andrews, B.; Ogren, J.; Kleinman, L.; Daum, P.; Berg, L.; Berkowitz, C.

    2007-12-01

    Chemical composition of submicron aerosol particles was determined using an Aerodyne Time-of-Flight Aerosol Mass Spectrometer (AMS) outfitted on the DOE G-1 aircraft during the Cumulus Humilis Aerosol Processing Study (CHAPS) conducted in Oklahoma City area in June 2007. The primary objective of CHAPS was to investigate the effects of urban emissions on cloud aerosol interactions as a function of processing of the emissions. Aerosol composition was typically determined at three different altitudes: below, in, and above cloud, in both upwind and downwind regions of the urban area. Aerosols were sampled from an isokinetic inlet with an upper size cut-off of ~1.5 micrometer. During cloud passages, the AMS also sampled particles that were dried from cloud droplets collected using a counter-flow virtual impactor (CVI) sampler. The aerosol mass concentrations were typically below 10 microgram per cubic meter, and were dominated by organics and sulfate. Ammonium was often less than required for complete neutralization of sulfate. Aerosol nitrate levels were very low. We noted that nitrate levels were significantly enhanced in cloud droplets compared to aerosols, most likely resulting from dissolution of gaseous nitric acid. Organic to sulfate ratios appeared to be lower in cloud droplets than in aerosols, suggesting cloud condensation nuclei properties of aerosol particles might be affected by loading and nature of the organic components in aerosols. In-cloud formation of sulfate was considered unimportant because of the very low SO2 concentration in the region. A detailed examination of the sources of the aerosol organic components (based on hydrocarbons determined using a proton transfer reaction mass spectrometer) and their effects on cloud formation as a function of atmospheric processing (based on the degree of oxidation of the organic components) will be presented.

  6. Radioactive gas inhalator

    International Nuclear Information System (INIS)

    LeMon, D.E.

    1975-01-01

    An ''inhalator'', or more particularly an apparatus for permitting a patient to inhale a radioactive gas in order to provide a diagnostic test of the patient's lung area, is described. The disclosed apparatus provides a simple, trouble-free mechanism for achieving this result; and, furthermore, provides an improved testing method. Moreover, the disclosed apparatus has the capability of gradually introducing the test condition in a manner that makes it easy for the patient to become acclimated to it. (U.S.)

  7. Functional design criteria for the retained gas sampler system

    International Nuclear Information System (INIS)

    Wootan, D.W.

    1995-01-01

    A Retained Gas Sampler System (RGSS) is being developed to capture and analyze waste samples from Hanford Flammable Gas Watch List Tanks to determine both the quantity and composition of gases retained in the waste. The RGSS consists of three main components: the Sampler, Extractor, and Extruder. This report describes the functional criteria for the design of the RGSS components. The RGSS Sampler is based on the WHC Universal Sampler design with modifications to eliminate gas leakage. The primary function of the Sampler is to capture a representative waste sample from a tank and transport the sample with minimal loss of gas content from the tank to the laboratory. The function of the Extruder is to transfer the waste sample from the Sampler to the Extractor. The function of the Extractor is to separate the gases from the liquids and solids, measure the relative volume of gas to determine the void fraction, and remove and analyze the gas constituents

  8. Characterization of the GENT PM10 sampler. Appendix 18

    International Nuclear Information System (INIS)

    Hopke, Philip K.; Xie Ying; Raunemaa, Taisto; Biegalski, Steven; Landsberger, Sheldon

    1995-01-01

    An integral part of the Co-ordinated Research Programme: Applied Research on Air Pollution using Nuclear-Related Analytical Techniques is the PM 10 sampler that was designed by Dr. W. Maenhaut of the University of Gent. Each participant was provided with such a sampler so that comparable samples will be obtained by each of the participating groups. Thus, in order to understand the characteristics of this sampler, we have undertaken several characterization studies in which we have examine the aerodynamic collection characteristics of the impactor inlet and the reproducibility of the sample mass collection. The sampler does provide a collection efficiency that follows the guidelines for a PM 10 sampler. Comparing one of the original samplers built at the University of Gent with a unit built from the same plans at Clarkson University showed good reproducibility in mass collection. (author)

  9. DOSEmanPRO - active electronic online personal air sampler for detection of radon progeny long lived alpha nuclides

    International Nuclear Information System (INIS)

    Streil, T.; Oeser, V.

    2002-01-01

    Full text: Using the micro system - technology we developed a online personal air sampler not bigger than a mobile phone, to open a new dimension in personal dosimetry of inhaled radioactive aerosols. The DOSEman PRO containing an internal pump with a continuous air flow of 0.15 I/min sample the radon progeny or other nuclides on a millipore filter with excellent spectroscopic resolution. A 1.5 cm 2 light protected ion-implanted silicon detector analyses the alpha radiation at the filter. This small detector head contains also the pre amplification and pulse processing. The alpha radiation of the radon progeny and the long lived alpha nuclides is analyzed by a 60 channel spectrometer. The energy resolution of the online analyzed filter spectra is in the order of 150 keV. Mechanical and electronic design enables one to distinguish the long lived alpha nuclides from the radon and thoron progeny very easily. Using a special algorithm we correct the influence of the tailing of the radon progeny to the long lived alpha nuclides and take into consideration possible interference in determining the long lived alpha nuclides. Because of the air sampling volume of nearly 10 I/h, the system has a high efficiency. The detection limit by 2 hours sampling time is 0.05 Bq/m 3 alpha nuclide concentration. In a modified device for air sampling especially of long-lived alpha nuclides like uranium, radium or plutonium, the flow rate is increased to 0,3 1/min e.g. during a 10 h sampling period we can detect 0.005 Bq/m 3 in a low radon atmosphere. Assuming increased radon progeny concentration, the statistical error for the long lived alpha nuclides will be higher, but in most of the cases for use in nuclear facilities low radon concentrations are ambient conditions. This concept of an electronic personal air sampler with an alpha spectroscopy offers some outstanding advantages compared to passive dosimeters or off-line alpha air filters: The dose value and the nuclide concentration is

  10. Environmental monitoring of tritium in air with passive diffusion samplers

    International Nuclear Information System (INIS)

    Wood, M.J.; Workman, W.J.G.

    1992-01-01

    This paper reports on a field trail in which outdoor air was sampled with an active reference sampler and several passive HTO-in-air samplers simultaneously carried out at Chalk River Laboratories. Both passive and active samplers were changed on an approximately monthly schedule from 1990 September 2 to 1991 April 18. Average temperatures for the sampling intervals ranged from -8.06 degrees C to +15.5 degrees C and HTO-in-air concentrations measured by the active sampler were typically 10 Bq/m 3 . A total of 1290 passive HTO-in-air sampler measurements were made during the seven sampling intervals. The passive samplers used for the field trial were prepared with either tritium-free water or a solution of 50% tritium-free water and 50% ethylene glycol. As expected, the samplers prepared with the water-glycol solution performed more consistently than the samplers prepared with water only. Good agreement between passive and active sampler measurements was observed throughout the field trial

  11. Continuous air monitor for alpha-emitting aerosol particles

    International Nuclear Information System (INIS)

    McFarland, A.R.; Ortiz, C.A.; Rodgers, J.C.; Nelson, D.C.

    1991-01-01

    A new alpha continuous air monitor (CAM) sampler is being developed for use in detecting the presence of alpha-emitting aerosol particles. The effort involves design, fabrication and evaluation of systems for the collection of aerosol and for the processing of data to speciate and quantify the alpha emitters of the interest. At the present time the authors have a prototype of the aerosol sampling system and they have performed wind tunnel tests to characterize the performance of the device for different particle sizes, wind speeds, flow rates and internal design parameters. The results presented herein deal with the aerosol sampling aspects of the new CAM sampler. Wind tunnel tests show that ≥ 50% of 10 μm aerodynamic equivalent diameter (AED) particles penetrate the flow system from the ambient air to the collection filter when the flow rate is 57 L/min (2 cfm) and the wind speed is 1 m/s. The coefficient of variation of deposits of 10 μm AED aerosol particles on the collection filter is 7%. An inlet fractionator for removing high mobility background aerosol particles has been designed and successfully tested. The results show that it is possible to strip 95% of freshly formed radon daughters and 33% of partially aged radon daughters from the aerosol sample. This approach offers the opportunity to improve the signal-to-noise ratio in the alpha energy spectrum region of interest thereby enhancing the performance of background compensation algorithms

  12. Determination of radionuclide concentrations in ground level air using the ASS-500 high volume sampler

    International Nuclear Information System (INIS)

    Frenzel, E.; Arnold, D.; Wershofen, H.

    1996-01-01

    A method for determination of radionuclide concentrations in air aerosol samples collected by the high volume aerosol sampler ASS-500 was elaborated. The aerosol sampling station ASS-500 is a Stand alone, all-weather proofed instrument. It is designed for representative sampling of airborne radionuclides from ground level air at a height of about 1.5 m above ground level. The ASS-500 station enables continuous air monitoring both normal and emergency Situations. The collection of aerosols on the Petrianov FPP-15-1.5 type filter out of an air volume of about 100,000 m 3 (sampling period 1 wk) or of about 250,000 m 3 (sampling period 3 wk) admits accurate spectrometric low level measurements of natural and artificial radionuclides. The achieved detection limit is 0.5 μBq m -3 and 0.2 μBq m -3 for 137 Cs, respectively. A new developed air flow Meter system allows to enhance the collected air volume to about 150,000 m 3 per week and lowers the detection limit to -3 for 137 Cs for weekly collected aerosol samples. In Poland the CLOR uses 9 Stations ASS-500 at different sites as atmospheric radioactivity control system. On the basis of spectrometric measurements of natural and artificial radionuclides in the collected aerosol samples at the different sites, CLOR establishes a weekly report about the radiological situation at Poland for responsible authorities. The very low achievable detection limit of the Station ASS-500 due 10 the high air flow fate and the long possible sampling period were the key argument for other government radiation protection authorities in Europe to introduce the Station ASS-500 into their low level radionuclide atmospheric monitoring programs (Austria, Belarus, France, Germany, Iceland, Spain, Switzerland, Ukraine)

  13. Radioactive Aerosol Size Distribution Measured in Nuclear Workplaces

    International Nuclear Information System (INIS)

    Kravchik, T.; Oved, S.; German, U.

    2002-01-01

    Inhalation is the main route for internal exposure of workers to radioactive aerosols in the nuclear industry.Aerosol's size distribution and in particular its activity median aerodynamic diameter (AMAD)is important for determining the fractional deposition of inhaled particles in the respiratory tract and the resulting doses. Respiratory tract models have been published by the International Commission on radiological Protection (ICRP).The former model has recommended a default AMAD of 1 micron for the calculation of dose coefficients for workers in the nuclear industry [1].The recent model recommends a 5 microns default diameter for occupational exposure which is considered to be more representative of workplace aerosols [2]. Several researches on radioactive aerosol's size distribution in nuclear workplaces has supported this recommendation [3,4].This paper presents the results of radioactive aerosols size distribution measurements taken at several workplaces of the uranium production process

  14. Retained gas sampler interim safety assessment

    Energy Technology Data Exchange (ETDEWEB)

    Pasamehmetoglu, K.O.; Miller, W.O.; Unal, C.; Fujita, R.K.

    1995-01-13

    This safety assessment addresses the proposed action to install, operate, and remove a Retained Gas Sampler (RGS) in Tank 101-SY at Hanford. Purpose of the RGS is to help characterize the gas species retained in the tank waste; the information will be used to refine models that predict the gas-producing behavior of the waste tank. The RGS will take samples of the tank from top to bottom; these samples will be analyzed for gas constituents. The proposed action is required as part of an evaluation of mitigation concepts for eliminating episodic gas releases that result in high hydrogen concentrations in the tank dome space.

  15. Retained gas sampler interim safety assessment

    International Nuclear Information System (INIS)

    Pasamehmetoglu, K.O.; Miller, W.O.; Unal, C.; Fujita, R.K.

    1995-01-01

    This safety assessment addresses the proposed action to install, operate, and remove a Retained Gas Sampler (RGS) in Tank 101-SY at Hanford. Purpose of the RGS is to help characterize the gas species retained in the tank waste; the information will be used to refine models that predict the gas-producing behavior of the waste tank. The RGS will take samples of the tank from top to bottom; these samples will be analyzed for gas constituents. The proposed action is required as part of an evaluation of mitigation concepts for eliminating episodic gas releases that result in high hydrogen concentrations in the tank dome space

  16. Field characterization of plutonium aerosols in mixed-oxide fuel fabrication

    International Nuclear Information System (INIS)

    Newton, G.J.; Teague, S.V.; Yeh, H.C.

    1976-01-01

    Nuclear reactor fuel pellets of PuO 2 and UO 2 are fabricated within safety enclosures at Babcock and Wilcox's Parker Township Site near Apolla, Pa. Nineteen sample runs were taken from within glove boxes of aerosols formed during powder comminution and blending. Eight sampling runs were also taken of a centerless grinding operation during routine industrial operations. A small seven-stage cascade impactor and the Lovelace Aerosol Particle Separator (LAPS) were used to determine aerodynamic size distribution and gross alpha aerosol concentrations. The potential toxicity of inhaled plutonium originating in the nuclear fuel cycle following accidental releases of these aerosols and possible inhalation by industrial workers is considered

  17. Aerosol Transport Over Equatorial Africa

    Science.gov (United States)

    Gatebe, C. K.; Tyson, P. D.; Annegarn, H. J.; Kinyua, A. M.; Piketh, S.; King, M.; Helas, G.

    1999-01-01

    Long-range and inter-hemispheric transport of atmospheric aerosols over equatorial Africa has received little attention so far. Most aerosol studies in the region have focussed on emissions from rain forest and savanna (both natural and biomass burning) and were carried out in the framework of programs such as DECAFE (Dynamique et Chimie Atmospherique en Foret Equatoriale) and FOS (Fires of Savanna). Considering the importance of this topic, aerosols samples were measured in different seasons at 4420 meters on Mt Kenya and on the equator. The study is based on continuous aerosol sampling on a two stage (fine and coarse) streaker sampler and elemental analysis by Particle Induced X-ray Emission. Continuous samples were collected for two seasons coinciding with late austral winter and early austral spring of 1997 and austral summer of 1998. Source area identification is by trajectory analysis and sources types by statistical techniques. Major meridional transports of material are observed with fine-fraction silicon (31 to 68 %) in aeolian dust and anthropogenic sulfur (9 to 18 %) being the major constituents of the total aerosol loading for the two seasons. Marine aerosol chlorine (4 to 6 %), potassium (3 to 5 %) and iron (1 to 2 %) make up the important components of the total material transport over Kenya. Minimum sulfur fluxes are associated with recirculation of sulfur-free air over equatorial Africa, while maximum sulfur concentrations are observed following passage over the industrial heartland of South Africa or transport over the Zambian/Congo Copperbelt. Chlorine is advected from the ocean and is accompanied by aeolian dust recirculating back to land from mid-oceanic regions. Biomass burning products are transported from the horn of Africa. Mineral dust from the Sahara is transported towards the Far East and then transported back within equatorial easterlies to Mt Kenya. This was observed during austral summer and coincided with the dying phase of 1997/98 El

  18. Direct analysis of airborne mite allergen (Der f1) in the residential atmosphere by chemifluorescent immunoassay using bioaerosol sampler.

    Science.gov (United States)

    Miyajima, Kumiko; Suzuki, Yurika; Miki, Daisuke; Arai, Moeka; Arakawa, Takahiro; Shimomura, Hiroji; Shiba, Kiyoko; Mitsubayashi, Kohji

    2014-06-01

    Dermatophagoides farinae allergen (Der f1) is one of the most important indoor allergens associated with allergic diseases in humans. Mite allergen Der f1 is usually associated with particles of high molecular weight; thus, Der f1 is generally present in settled dust. However, a small quantity of Der f1 can be aerosolized and become an airborne component. Until now, a reliable method of detecting airborne Der f1 has not been developed. The aim of this study was to develop a fiber-optic chemifluorescent immunoassay for the detection of airborne Der f1. In this method, the Der f1 concentration measured on the basis of the intensity of fluorescence amplified by an enzymatic reaction between the labeled enzyme by a detection antibody and a fluorescent substrate. The measured Der f1 concentration was in the range from 0.49 to 250 ng/ml and a similar range was found by enzyme-linked immunosorbent assay (ELISA). This method was proved to be highly sensitive to Der f1 compared with other airborne allergens. For the implementation of airborne allergen measurement in a residential environment, a bioaerosol sampler was constructed. The airborne allergen generated by a nebulizer was conveyed to a newly sampler we developed for collecting airborne Der f1. The sampler was composed of polymethyl methacrylate (PMMA) cells for gas/liquid phases and some porous membranes which were sandwiched in between the two phases. Der f1 in air was collected by the sampler and measured using the fiber-optic immunoassay system. The concentration of Der f1 in aerosolized standards was in the range from 0.125 to 2.0 mg/m(3) and the collection rate of the device was approximately 0.2%. © 2013 Elsevier B.V. All rights reserved.

  19. The penetration of aerosols through fine capillaries

    International Nuclear Information System (INIS)

    Mitchell, J.P.; Edwards, R.T.; Ball, M.H.E.

    1989-10-01

    A novel experimental technique has been developed to study the penetration of aerosol particles ranging from about 1 to 15 μm aerodynamic diameter through capillaries varying from 20 to 80 μm bore and from 10 to 50 mm in length. When the driving pressure was 100 kPa, the penetration of the airborne particles was considerably smaller than expected from a simple comparison of particle diameter with the bore of the capillary. Particle size distributions determined after penetration through the capillaries were in almost all cases similar to the particle size distribution of the aerosol at the capillary entrance. This lack of size-selectivity can be explained in terms of the capillary behaving as a conventional suction-based sampler from a near still (calm) air environment. The resulting particle penetration data are important in assessing the potential for the leakage of aerosols through seals in containers used to transport radioactive materials. (author)

  20. An innovative discrete multilevel sampler design

    International Nuclear Information System (INIS)

    Marvin, B.K.; De Clercq, P.J.; Taylor, B.B.; Mauro, D.M.

    1995-01-01

    An innovative, small-diameter PVC discrete multilevel sampler (DMLS) was designed for the Electric Power Research Institute (EPRI) to provide low-cost, discrete groundwater samples from shallow aquifers. When combined with appropriately-sized direct push soil sampling technologies, high resolution aquifer characterization can be achieved during initial site assessment or remediation monitoring activities. The sampler is constructed from 1-inch diameter PVC well materials, containing polyethylene tubing threaded through PVC disks. Self-expanding annular and internal bentonite seals were developed which isolate discrete sampling zones. The DMLS design allows customization of sampling and isolation zone lengths to suit site-specific goals. Installation of the DMLS is achieved using a temporary, expendable-tipped casting driven by direct push methods. This technique minimizes mobilization costs, site and soil column disturbances, and allows rapid installation in areas of limited overhead clearance. Successful pilot installations of the DMLS prototype have been made at a former manufactured gas plant (MGP) site and a diesel fuel spill site. Analysis of groundwater samples from these sites, using relative compound distributions and contaminant concentration profiling, confirmed that representative discrete samples were collected. This design provides both economical and versatile groundwater monitoring during all phases of site assessment and remediation

  1. Air sampler performance at Ford's farm range

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.; Johnston, J.W.

    1984-07-01

    An air-sampling system for a large-caliber depleted uranium (DU) penetrator firing range was tested. The objectives of the test were: to determine the bias between the monitoring readings and DU concentrations; and to determine if the target bay real-time monitor (RTM) tracks the decaying dust concentration. The test procedure was to operate total and respirable airborne particle samplers adjacent to the target bay monitors. A series of air samples was also taken after the test firings adjacent to the target bay RTM. Exhaust particle samples were analyzed for gross alpha, gross beta and uranium content. The target bay RTM correlated well (0.977) with the sequential samples. Average concentration from the RTM did not correlate with either the long-term total or respirable sampler DU concentrations. The monitor used to confirm a low dust concentration when the door is open correlated well (0.810) with the RTM; the other bay monitor did not. In the ventilation discharge, the long-term average monitor readings did not correlate with DU concentrations, probably due to levels near lower detection limits. Smearable surface-contamination samples showed highest contamination on the equipment, gravel floor and exhaust intake. The location air-intake contamination increased over the first 3 rounds. Contamination was reduced by a low-pressure water spray washdown to about the same concentration as often the second round, then remained at about twice the level. 2 references, 18 figures, 16 tables. (MF)

  2. Inhalation Toxicology Research Institute annual report 1987-1988

    International Nuclear Information System (INIS)

    Mauderly, J.L.; Mewhinney, J.A.; Bechtold, W.E.; Sun, J.D.; Coons, T.A.

    1988-12-01

    The mission of the Inhalation Toxicology Research Institute is to investigate the magnitude of human health effects that result from the inhalation of airborne materials at home, in the work place, or in the general environment. Diseases of the respiratory tract are major causes of suffering and death, and many of these diseases are directly related to the materials that people breath. The Institute's research is directed toward obtaining a better understanding of the basic biology of the respiratory tract and the mechanisms by which inhaled materials produce respiratory disease. Special attention is focused on studying the airborne materials released by various energy technologies, as well as those associated with national defense activities. The research uses a wide-ranging, comprehensive array of investigative approaches that are directed toward characterizing the source of the airborne material, following the material through its potential transformation in the air, identifying the mechanisms that govern its inhalation and deposition in the respiratory tract, and determining the fate of these inhaled materials in the body and the health effects they produce. The ultimate objectives are to determine the roles played by inhaled materials in the development of disease processes adn to estimate the risk they pose by inhaled materials in the development of disease processes and to estimate the risk they pose to humans who may be exposed to them. This report contains brief research papers that reflect the scope and recent findings of the Institute's research funded by the U.S. Department of Energy, principally through the Office of Health and Environmental Research. The papers are divided into topical sections. The first section, Characterization of Airborne Materials and Generation of Experimental Exposure Atmospheres, reflects the Institute's capabilities for fundamental aerosol research and the application of that expertise to toxicological studies. The second

  3. Inhalation Toxicology Research Institute annual report 1987-1988

    Energy Technology Data Exchange (ETDEWEB)

    Mauderly, J L; Mewhinney, J A; Bechtold, W E; Sun, J D; Coons, T A [eds.

    1988-12-01

    The mission of the Inhalation Toxicology Research Institute is to investigate the magnitude of human health effects that result from the inhalation of airborne materials at home, in the work place, or in the general environment. Diseases of the respiratory tract are major causes of suffering and death, and many of these diseases are directly related to the materials that people breath. The Institute's research is directed toward obtaining a better understanding of the basic biology of the respiratory tract and the mechanisms by which inhaled materials produce respiratory disease. Special attention is focused on studying the airborne materials released by various energy technologies, as well as those associated with national defense activities. The research uses a wide-ranging, comprehensive array of investigative approaches that are directed toward characterizing the source of the airborne material, following the material through its potential transformation in the air, identifying the mechanisms that govern its inhalation and deposition in the respiratory tract, and determining the fate of these inhaled materials in the body and the health effects they produce. The ultimate objectives are to determine the roles played by inhaled materials in the development of disease processes adn to estimate the risk they pose by inhaled materials in the development of disease processes and to estimate the risk they pose to humans who may be exposed to them. This report contains brief research papers that reflect the scope and recent findings of the Institute's research funded by the U.S. Department of Energy, principally through the Office of Health and Environmental Research. The papers are divided into topical sections. The first section, Characterization of Airborne Materials and Generation of Experimental Exposure Atmospheres, reflects the Institute's capabilities for fundamental aerosol research and the application of that expertise to toxicological studies. The second

  4. Internal dosimetric evaluation due to uranium aerosols; Evaluacion dosimetrica interna debido a aerosoles de uranio

    Energy Technology Data Exchange (ETDEWEB)

    Juan, Garcia Aguilar; Gustavo, Delgado Avila [Instituto Nacional de Investigaciones Nucleares, Salazar (Mexico)

    1991-07-01

    The present work has like object to carry out the internal dosimetric evaluation to the occupationally exposed personnel, due to the inhalation of aerosols of natural uranium and enriched in the pilot plant of nuclear fuel production of the National Institute of Nuclear Research.

  5. Radioaerosol inhalation lung scintigraphy in bronchial asthma

    International Nuclear Information System (INIS)

    Chiba, Takashi

    1993-01-01

    A study on obstructive changes in airways and mucociliary clearance in children and youth with bronchial asthma was performed. Radioaerosol inhalation lung scintigraphies using 99T c-human serum albumin (HSA) were applied to 50 children and youth with bronchial asthma. The deposition patterns of the radioaerosol and aerosol clearance curves were evaluated. Abnormal deposition patterns, which consisted of non-homogeneous distribution and/or hot spot formation, were likely to be seen in patients with asthmatic attacks at the time of measurements. However, a few asymptomatic patients also revealed abnormal deposition patterns. The deposition patterns were related to FEV 1.0 %, MMF, V 50 and V 25 , but especially to FEV 1.0 %. As an index of mucociliary clearance, β, the rate constant of the 99m Tc-HSA aerosol clearance curve, was introduced. β was significantly lower in patients with abnormal aerosol deposition patterns than in normal persons. β was also significantly lower in patients undergoing asthmatic attack at the time of the measurements than in asymptomatic patients. β correlated negatively with FEV 1.0 %, MMF, V 50 and V 25 , but especially with FEV 1.0 %. Although patients with long term affection or moderate-to-severe asthma tended to reveal abnormal deposition patterns and had low β values, these differences were not statistically significant. Radioaerosol inhalation lung scintigraphy with 99m Tc-HSA is useful for evaluating not only obstructive changes in the airways but also for evaluating mucociliary clearance in children with bronchial asthma. (author)

  6. Inhaled americium dioxide

    International Nuclear Information System (INIS)

    Park, J.F.

    1982-01-01

    This project includes experiments to determine the effects of Zn-DTPA therapy on the retention, translocation and biological effects of inhaled 241 AmO 2 . Beagle dogs that received inhalation exposure to 241 AmO 2 developed leukopenia, clincial chemistry changes associated with hepatocellular damage, and were euthanized due to respiratory insufficiency caused by radiation pneumonitis 120 to 131 days after pulmonary deposition of 22 to 65 μCi 241 Am. Another group of dogs that received inhalation exposure to 241 AmO 2 and were treated daily with Zn-DTPA had initial pulmonary deposition of 19 to 26 μCi 241 Am. These dogs did not develop respiratory insufficiency, and hematologic and clinical chemistry changes were less severe than in the non-DTPA-treated dogs

  7. Applications of particle induced X-ray emission analysis to ambient aerosol studies

    International Nuclear Information System (INIS)

    Lannefors, H.

    1982-01-01

    The characteristics of Particle Induced X-ray Emission (PIXE) analysis in conjunction with different ambient aerosol samplers have been studied. Correction factors have been calculated for homogeneous and inhomogeneous rural and urban aerosol samples. The Nuclepore two stage filter sampler provided the most useful combination of the resolution and particle size fractionation in urban, rural and remote environments. The PIXE-analysis technique in combination with different samplers was employed in aerosol composition studies in rural and remote environments. Particular emphasis was laid on studies of aerosol long range transport. Based on air mass trajectory analysis and aerosol composition measurements the foreign contribution in southern Sweden was estimated to be 70 - 80% for S and Pb but only 30 - 50% for V and Ni. The spatial and temporal extension of a long range transport episode was studied using high time resolution continuous filter samplers in a network in southern Sweden. The variation in the concentration levels of sulphur agreed well with changes in the air mass history. Arctic summer elemental concentration levels as measured during the Swedish YMER-80 icebreaker expedition were typically one order of magnitude lower than Arctic winter levels. The combination of chemical information, optical properties and size distribution data supports the hypothesis of long range transport of air pollution into the Arctic especially during the winter. This takes place during the winter season because the Polar front is further south making conditions for long range transport up to the Arctic more favourable. (Auth.)

  8. Performance characteristics of a low-volume PM10 sampler

    Science.gov (United States)

    Four identical PM10 pre-separators, along with four identical low-volume (1m3 hr-1) total suspended particulate (TSP) samplers were tested side-by-side in a controlled laboratory particulate matter (PM) chamber. The four PM10 and four TSP samplers were also tested in an oil pipe-cleaning field to ev...

  9. Optimal relaxed causal sampler using sampled-date system theory

    NARCIS (Netherlands)

    Shekhawat, Hanumant; Meinsma, Gjerrit

    This paper studies the design of an optimal relaxed causal sampler using sampled data system theory. A lifted frequency domain approach is used to obtain the existence conditions and the optimal sampler. A state space formulation of the results is also provided. The resulting optimal relaxed causal

  10. Passive sampler for dissolved organic matter in freshwater environments.

    Science.gov (United States)

    Lam, Buuan; Simpson, André J

    2006-12-15

    A passive sampler for the isolation of dissolved organic matter (DOM) from freshwater environments is described. The sampler consists of a molecular weight selective membrane (1000 kDa) and an anion exchange resin (diethylaminoethylcellulose (DEAE-cellulose)). NMR indicates the samplers isolate DOM that is nearly indistinguishable from that isolated using the batch DEAE-cellulose procedure. In a comparative study DOM isolated from Lake Ontario cost approximately 0.30 dollars/mg to isolate using the passive samplers while DOM isolated using the traditional batch procedure cost approximately 8-10 dollars/mg. The samplers have been shown to be effective in a range of freshwater environments including a large inland lake (Lake Ontario), fast flowing tributary, and wetland. Large amounts (gram quantities of DOM) can be easily isolated by increasing the size or number of samplers deployed. Samplers are easy to construct, negate the need for pressure filtering, and also permit a range of temporal and spatial experiments that would be very difficult or impossible to perform using conventional approaches. For example, DOM can be monitored on a regular basis at numerous different locations, or samplers could be set at different depths in large lakes. Furthermore, they could potentially be deployed into hard to reach environments such as wells, groundwater aquifers, etc., and as they are easy to use, they can be mailed to colleagues or included with expeditions going to difficult to reach places such as the Arctic and Antarctic.

  11. Organ burdens and elimination rates of inhaled thorium and plutonium

    International Nuclear Information System (INIS)

    Unnikrishnan, K.; Murthy, K.B.S.; Sunta, C.M.

    1986-01-01

    For the purpose of interpreting observations from internal monitoring programmes, organ burdens and excretion rates resulting from inhalation of long-lived isotopes of plutonium and thorium have been calculated, on the basis of the ICRP model. Two types of inhalation, instantaneous (acute) and at a steady rate (chronic) are considered. The expected buildups of the burden in lungs, lymph nodes, bone, liver and other tissues, as well as the excretion rates, have been calculated for aerosol classes W and Y, and particle sizes of AMAD 1 μm and 6 μm. Further, in view of their use in selecting the periodicity of routine monitoring, theoretical results are also presented for the case of a total inhalation of 1 ALI in one year, instantaneously or at a constant rate. (author)

  12. Know How to Use Your Asthma Inhaler

    Medline Plus

    Full Text Available ... KB] Using a metered dose inhaler (inhaler in mouth) Your browser does not support iframes Using a metered dose inhaler (inhaler in mouth) [PDF – 370 KB] Your browser does not support ...

  13. Development of Respimat® Soft Mist™ Inhaler and its clinical utility in respiratory disorders

    Directory of Open Access Journals (Sweden)

    Dalby RN

    2011-09-01

    Full Text Available Richard N Dalby1, Joachim Eicher2, Bernd Zierenberg21Department of Pharmaceutical Sciences, University of Maryland, Baltimore, MD, USA; 2Boehringer Ingelheim, Ingelheim, GermanyAbstract: The Respimat® Soft Mist™ Inhaler (SMI (Boehringer Ingelheim International GmbH, Ingelheim, Germany was developed in response to the need for a pocket-sized device that can generate a single-breath, inhalable aerosol from a drug solution using a patient-independent, reproducible, and environmentally friendly energy supply. This paper describes the design and evolution of this innovative device from a laboratory concept model and the challenges that were overcome during its development and scaleup to mass production. A key technical breakthrough was the uniblock, a component combining filters and nozzles and made of silicon and glass, through which drug solution is forced using mechanical power. This allows two converging jets of solution to collide at a controlled angle, generating a fine aerosol of inhalable droplets. The mechanical energy comes from a spring which is tensioned by twisting the base of the device before use. Additional features of the Respimat® SMI include a dose indicator and a lockout mechanism to avoid the problems of tailing-off of dose size seen with pressurized metered dose inhalers. The Respimat® SMI aerosol cloud has a unique range of technical properties. The high fine particle fraction allied with the low velocity and long generation time of the aerosol translate into a higher fraction of the emitted dose being deposited in the lungs compared with aerosols from pressurized metered dose inhalers and dry powder inhalers. These advantages are realized in clinical trials in adults and children with obstructive lung diseases, which have shown that the efficacy and safety of a pressurized metered dose inhaler formulation of a combination bronchodilator can be matched by a Respimat® SMI formulation containing only one half or one quarter

  14. Siting Samplers to Minimize Expected Time to Detection

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Travis; Lorenzetti, David M.; Sohn, Michael D.

    2012-05-02

    We present a probabilistic approach to designing an indoor sampler network for detecting an accidental or intentional chemical or biological release, and demonstrate it for a real building. In an earlier paper, Sohn and Lorenzetti(1) developed a proof of concept algorithm that assumed samplers could return measurements only slowly (on the order of hours). This led to optimal detect to treat architectures, which maximize the probability of detecting a release. This paper develops a more general approach, and applies it to samplers that can return measurements relatively quickly (in minutes). This leads to optimal detect to warn architectures, which minimize the expected time to detection. Using a model of a real, large, commercial building, we demonstrate the approach by optimizing networks against uncertain release locations, source terms, and sampler characteristics. Finally, we speculate on rules of thumb for general sampler placement.

  15. Airway irritation, inflammation, and toxicity in mice following inhalation of metal oxide nanoparticles

    DEFF Research Database (Denmark)

    Larsen, Søren T; Jackson, Petra; Poulsen, Steen S

    2016-01-01

    Metal oxide nanoparticles are used in a broad range of industrial processes and workers may be exposed to aerosols of the particles both during production and handling. Despite the widespread use of these particles, relatively few studies have been performed to investigate the toxicological effects...... in the airways following inhalation. In the present study, the acute (24 h) and persistent (13 weeks) effects in the airways after a single exposure to metal oxide nanoparticles were studied using a murine inhalation model. Mice were exposed 60 min to aerosols of either ZnO, TiO2, Al2O3 or CeO2 and the deposited...

  16. Aerosol Deposition in Health and Disease

    Science.gov (United States)

    2012-01-01

    Abstract The success of inhalation therapy is not only dependent upon the pharmacology of the drugs being inhaled but also upon the site and extent of deposition in the respiratory tract. This article reviews the main mechanisms affecting the transport and deposition of inhaled aerosol in the human lung. Aerosol deposition in both the healthy and diseased lung is described mainly based on the results of human studies using nonimaging techniques. This is followed by a discussion of the effect of flow regime on aerosol deposition. Finally, the link between therapeutic effects of inhaled drugs and their deposition pattern is briefly addressed. Data show that total lung deposition is a poor predictor of clinical outcome, and that regional deposition needs to be assessed to predict therapeutic effectiveness. Indeed, spatial distribution of deposited particles and, as a consequence, drug efficiency is strongly affected by particle size. Large particles (>6 μm) tend to mainly deposit in the upper airway, limiting the amount of drugs that can be delivered to the lung. Small particles (<2 μm) deposit mainly in the alveolar region and are probably the most apt to act systemically, whereas the particle in the size range 2–6 μm are be best suited to treat the central and small airways. PMID:22686623

  17. Side-by-side determination of workers' exposure to wood dust with IOM and open-faced samplers.

    Science.gov (United States)

    Cavlović, Anka Ozana; Beljo Lučić, Ružica; Jug, Matija; Radmanović, Kristijan; Bešlić, Ivan

    2013-09-01

    Woodworkers' exposure to airborne particles is measured with different sampling techniques throughout the world. Due to a great number of exposure data obtained with different samplers, European countries have aimed over the last ten years to find a conversion factor for mass concentrations that would render these measurements comparable. Following the accepted EU standards and regulations, we replaced a 25 mm open-faced (OF) filter holder with an IOM head to determine woodworkers' exposure to inhalable dust and establish an IOM/OF sampler ratio that might serve as a reliable factor for converting the existing OF data to IOM dust mass concentration in the industrial environment. For this side-by-side sampling we used personal 25 mm OF (N=29) and IOM (N=29) sampling heads over eight working hours. The obtained IOM/OF ratios ranged between 0.7 and 2.3. However, mass concentrations obtained by IOM and OF samplers did not significantly differ. Our findings suggest that there is no need for conversion of the existing OF data for workers exposed to wood dust, provided that dust mass concentrations in the working environment range between 1 mg m-3 and 7 mg m-3. Future side-by-side measurements should also involve environments with low wood dust mass concentrations.

  18. Radiation exposure and risk estimates for inhaled airborne radioactive pollutants including hot particles. Annual report 1 July 1976--30 June 1977

    International Nuclear Information System (INIS)

    Mewhinney, J.A.

    1978-03-01

    Contents: Mixed-oxide fuel fabrication; Generation of aerosols of mixed uranium-plutonium oxides from dry powders for animal inhalation exposures; Analytical radiochemical determination of U, Pu and Am in biological samples; Physical chemical characterization of mixed uranium-plutonium oxide nuclear fuel as samples during animal inhalation exposure; Pilot studies of deposition and retention of industrial mixed-oxide aerosols in the laboratory rat; Extended radiation dose pattern studies of aerosols of mixed uranium-plutonium oxides treated at 750C inhaled by Fishcer-344 rats, beagle dogs and cynomolgus monkeys; Extended radiation dose pattern studies of aerosols of plutonium dioxide, treated at 850C and inhaled by Fischer-344 rats, beagle dogs and cynomolgus monkeys

  19. Investigation of electrostatic behavior of a lactose carrier for dry powder inhalers.

    Science.gov (United States)

    Chow, Keat Theng; Zhu, Kewu; Tan, Reginald B H; Heng, Paul W S

    2008-12-01

    This study aims to elucidate the electrostatic behavior of a model lactose carrier used in dry powder inhaler formulations by examining the effects of ambient relative humidity (RH), aerosolization air flow rate, repeated inhaler use, gelatin capsule and tapping on the specific charge (nC/g) of bulk and aerosolized lactose. Static and dynamic electrostatic charge measurements were performed using a Faraday cage connected to an electrometer. Experiments were conducted inside a walk-in environmental chamber at 25 degrees C and RHs of 20% to 80%. Aerosolization was achieved using air flow rates of 30, 45, 60 and 75 L/min. The initial charges of the bulk and capsulated lactose were a magnitude lower than the charges of tapped or aerosolized lactose. Dynamic charge increased linearly with aerosolization air flow rate and RH. Greater frictional forces at higher air flow rate induced higher electrostatic charges. Increased RH enhanced charge generation. Repeated inhaler use significantly influenced electrostatic charge due to repeated usage. This study demonstrated the significance of interacting influences by variables commonly encountered in the use DPI such as variation in patient's inspiratory flow rate, ambient RH and repeated inhaler use on the electrostatic behavior of a lactose DPI carrier.

  20. Real-time measurement of inhaled and exhaled cigarette smoke: Implications for dose

    Energy Technology Data Exchange (ETDEWEB)

    McGrath, Conor; Warren, Nigel; Biggs, Philip; McAughey, John, E-mail: conor_mcgrath@bat.co [British American Tobacco, Group R and D Centre, Southampton, SO15 8TL (United Kingdom)

    2009-02-01

    Inhalation of tobacco smoke aerosol is a two-step process involving puffing followed by inhalation. Measured smoke deposition efficiencies in the lung (20-70%) are greater than expected for smoke particles of 150 -- 250 nm count median diameter (CMD). Various mechanisms have been put forward to explain this enhanced deposition pattern, including coagulation, hygroscopic growth, condensation and evaporation, changes in composition, or changes in inhalation behaviour. This paper represents one of a series of studies seeking to better quantify smoke chemistry, inhalation behaviour and cumulative particle growth. The studies have been conducted to better understand smoke dosimetry and links to disease as part of a wider programme defining risk and potential harm reduction. In this study, the average CMD of inhaled smoke was 160 nm while the average CMD of exhaled smoke was 239 nm with an average growth factor of 1.5.

  1. Real-time measurement of inhaled and exhaled cigarette smoke: Implications for dose

    International Nuclear Information System (INIS)

    McGrath, Conor; Warren, Nigel; Biggs, Philip; McAughey, John

    2009-01-01

    Inhalation of tobacco smoke aerosol is a two-step process involving puffing followed by inhalation. Measured smoke deposition efficiencies in the lung (20-70%) are greater than expected for smoke particles of 150 -- 250 nm count median diameter (CMD). Various mechanisms have been put forward to explain this enhanced deposition pattern, including coagulation, hygroscopic growth, condensation and evaporation, changes in composition, or changes in inhalation behaviour. This paper represents one of a series of studies seeking to better quantify smoke chemistry, inhalation behaviour and cumulative particle growth. The studies have been conducted to better understand smoke dosimetry and links to disease as part of a wider programme defining risk and potential harm reduction. In this study, the average CMD of inhaled smoke was 160 nm while the average CMD of exhaled smoke was 239 nm with an average growth factor of 1.5.

  2. BCE selector valves and flow proportional sampler

    International Nuclear Information System (INIS)

    Rippy, G.L.

    1994-01-01

    This Acceptance Test Procedure (ATP) has been prepared to demonstrate that the Electrical/Instrumentation systems for the B-Plant Process Condensate Treatment Facility (BCE) function as required by project criteria. Tests will be run to: Verify the operation of the solenoid valve and associated limit switches installed for the BCE portion of W-007H; Operate the solenoid valve and verify the proper operation of the associated limit switches based on the position of the solenoid valve;and, Demonstrate the integrity of the Sample Failure Alarm Relay XFA-211BA-BCE-1, and Power Failure ALarm Relay JFA-211BA-BCE-1 located inside the Flow Proportional Sampler in Building 211 BA

  3. Multipurpose sampler device for liquid metal

    International Nuclear Information System (INIS)

    Nelson, P.A.; Kolba, V.M.; Holmes, J.T.

    1975-01-01

    A device for collecting samples or examining a flow of liquid metal is provided for use with such as a liquid-metal-cooled nuclear reactor. The sampler device includes a casing surrounded by an external heater for establishing an upper isothermal zone and a lower zone for heating the entering liquid metal. One of various inserts is suspended into the isothermal zone where it is surrounded by a shroud tube for directing liquid-metal flow from the heating zone into the top of the insert. Discharge flow from the insert gravitates through a helically wound tube in heat exchange contact with entering liquid-metal flow within the heating zone. The inserts comprise an overflow cup with upper and lower freeze seals, a filter for removing particulate matter, and a fixture for maintaining various sample materials in equilibrium with liquid-metal flow. (U.S.)

  4. Aerosol studies

    International Nuclear Information System (INIS)

    Cristy, G.A.; Fish, M.E.

    1978-01-01

    As part of the continuing studies of the effects of very severe reactor accidents, an effort was made to develop, test, and improve simple, effective, and inexpensive methods by which the average citizen, using only materials readily available, could protect his residence, himself, and his family from injury by toxic aerosols. The methods for protection against radioactive aerosols should be equally effective against a clandestine biological attack by terrorists. The results of the tests to date are limited to showing that spores of the harmless bacterium, bacillus globegii (BG), can be used as a simulant for the radioactive aerosols. An aerosol generator of Lauterbach type was developed which will produce an essentially monodisperse aerosol at the rate of 10 9 spores/min. Analytical techniques have been established which give reproducible results. Preliminary field tests have been conducted to check out the components of the system. Preliminary tests of protective devices, such as ordinary vacuum sweepers, have given protection factors of over 1000

  5. Stratospheric aerosols

    International Nuclear Information System (INIS)

    Rosen, J.; Ivanov, V.A.

    1993-01-01

    Stratospheric aerosol measurements can provide both spatial and temporal data of sufficient resolution to be of use in climate models. Relatively recent results from a wide range of instrument techniques for measuring stratospheric aerosol parameters are described. Such techniques include impactor sampling, lidar system sensing, filter sampling, photoelectric particle counting, satellite extinction-sensing using the sun as a source, and optical depth probing, at sites mainly removed from tropospheric aerosol sources. Some of these techniques have also had correlative and intercomparison studies. The main methods for determining the vertical profiles of stratospheric aerosols are outlined: lidar extinction measurements from satellites; impactor measurements from balloons and aircraft; and photoelectric particle counter measurements from balloons, aircraft, and rockets. The conversion of the lidar backscatter to stratospheric aerosol mass loading is referred to. Absolute measurements of total solar extinction from satellite orbits can be used to extract the aerosol extinction, and several examples of vertical profiles of extinction obtained with the SAGE satellite are given. Stratospheric mass loading can be inferred from extinction using approximate linear relationships but under restrictive conditions. Impactor sampling is essentially the only method in which the physical nature of the stratospheric aerosol is observed visually. Vertical profiles of stratospheric aerosol number concentration using impactor data are presented. Typical profiles using a dual-size-range photoelectric dustsonde particle counter are given for volcanically disturbed and inactive periods. Some measurements of the global distribution of stratospheric aerosols are also presented. Volatility measurements are described, indicating that stratospheric aerosols are composed primarily of about 75% sulfuric acid and 25% water

  6. PHARMACEUTICAL AEROSOLS FOR THE TREATMENT AND PREVENTION OF TUBERCULOSIS

    Directory of Open Access Journals (Sweden)

    Shumaila N Muhammad Hanif

    2012-09-01

    Full Text Available Historically, pharmaceutical aerosols have been employed for the treatment of obstructive airway diseases, such as asthma and chronic obstructive pulmonary disease, but in the past decades their use has been expanded to treat lung infections associated with cystic fibrosis and other respiratory diseases. Tuberculosis (TB is acquired after inhalation of aerosol droplets containing the bacilli from the cough of infected individuals. Even though TB affects other organs, the lungs are the primary site of infection, which makes the pulmonary route an ideal alternative route to administer vaccines or drug treatments. Optimization of formulations and delivery systems for anti-TB vaccines and drugs, as well as the proper selection of the animal model to evaluate those is of paramount importance if novel vaccines or drug treatments are to be successful. Pharmaceutical aerosols for patient use are generated from metered dose inhalers, nebulizers and dry powder inhalers. In addition to the advantages of providing more efficient delivery of the drug, low cost and portability, pharmaceutical dry powder aerosols are more stable than inhalable liquid dosage forms and do not require refrigeration. Methods to manufacture dry powders in respirable sizes include micronization, spray drying and other proprietary technologies. Inhalable dry powders are characterized in terms of their drug content, particle size and dispersibility to ensure deposition in the appropriate lung region and effective aerosolization from the device. These methods will be illustrated as they were applied for the manufacture and characterization of powders containing anti-tubercular agents and vaccines for pulmonary administration. The influence of formulation, selection of animal model, method of aerosol generation and administration on the efficacy demonstrated in a given study will be illustrated by the evaluation of pharmaceutical aerosols of anti-TB drugs and vaccines in guinea pigs by

  7. Internal dosimetry of nuclear medicine workers through the analysis of 131I in aerosols

    International Nuclear Information System (INIS)

    Gomes C, L.; Lucena, E. A.; Da Silva S, C.; Almeida D, A. L.; Oliveira S, W.; Souza S, M.; Maranhao D, B.

    2014-08-01

    131 I is widely used in nuclear medicine for diagnostic and therapy of thyroid diseases. Depending of workplace safety conditions, routine handling of this radionuclide may result in a significant risk of exposure of the workers subject to chronic intake by inhalation of aerosols. A previous study including in vivo and in vitro measurements performed recently among nuclear medicine personnel in Brazil showed the occurrence of 131 I incorporation by workers involved in the handling of solutions used for radioiodine therapy. The present work describes the development, optimization and application of a methodology to collect and analyze aerosol samples aiming to assess internal doses based on the activity of 131 I present in a radiopharmacy laboratory. Portable samplers were positioned at one meter distant from the place where non-sealed liquid sources of 131 I are handled. Samples were collected over one hour using high-efficiency filters containing activated carbon and analyzed by gamma spectrometry with a high purity germanium detection system. Results have shown that, although a fume hood is available in the laboratory, 131 I in the form of vapor was detected in the workplace. The average activity concentration was found to be of 7.4 Bq /m 3 . This value is about three orders of magnitude below the Derived Air Concentration (Dac) of 8.4 kBq/m 3 . Assuming that the worker is exposed by inhalation of iodine vapor during one hour, 131 I concentration detected corresponds to an intake of 3.6 Bq which results in a committed effective dose of 7.13 x 10 -5 mSv. These results show that the radiopharmacy laboratory evaluated is safe in terms of internal exposure of the workers. However it is recommended that the presence of 131 I should be periodically re-assessed since it may increase individual effective doses. It should also be pointed out that the results obtained so far reflect a survey carried out in a specific workplace. Thus, it is suggested to apply the

  8. Internal dosimetry of nuclear medicine workers through the analysis of {sup 131}I in aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Gomes C, L.; Lucena, E. A.; Da Silva S, C.; Almeida D, A. L.; Oliveira S, W.; Souza S, M.; Maranhao D, B., E-mail: carneiro@ird.gov.br [Instituto de Radioprotecao e Dosimetria - CNEN, Av. Salvador Allende s/n, 22783-127 Rio de Janeiro (Brazil)

    2014-08-15

    {sup 131}I is widely used in nuclear medicine for diagnostic and therapy of thyroid diseases. Depending of workplace safety conditions, routine handling of this radionuclide may result in a significant risk of exposure of the workers subject to chronic intake by inhalation of aerosols. A previous study including in vivo and in vitro measurements performed recently among nuclear medicine personnel in Brazil showed the occurrence of {sup 131}I incorporation by workers involved in the handling of solutions used for radioiodine therapy. The present work describes the development, optimization and application of a methodology to collect and analyze aerosol samples aiming to assess internal doses based on the activity of {sup 131}I present in a radiopharmacy laboratory. Portable samplers were positioned at one meter distant from the place where non-sealed liquid sources of {sup 131}I are handled. Samples were collected over one hour using high-efficiency filters containing activated carbon and analyzed by gamma spectrometry with a high purity germanium detection system. Results have shown that, although a fume hood is available in the laboratory, {sup 131}I in the form of vapor was detected in the workplace. The average activity concentration was found to be of 7.4 Bq /m{sup 3}. This value is about three orders of magnitude below the Derived Air Concentration (Dac) of 8.4 kBq/m{sup 3}. Assuming that the worker is exposed by inhalation of iodine vapor during one hour, {sup 131}I concentration detected corresponds to an intake of 3.6 Bq which results in a committed effective dose of 7.13 x 10{sup -5} mSv. These results show that the radiopharmacy laboratory evaluated is safe in terms of internal exposure of the workers. However it is recommended that the presence of {sup 131}I should be periodically re-assessed since it may increase individual effective doses. It should also be pointed out that the results obtained so far reflect a survey carried out in a specific

  9. History of aerosol therapy: liquid nebulization to MDIs to DPIs.

    Science.gov (United States)

    Anderson, Paula J

    2005-09-01

    Inhaled therapies have been used since ancient times and may have had their origins with the smoking of datura preparations in India 4,000 years ago. In the late 18th and in the 19th century, earthenware inhalers were popular for the inhalation of air drawn through infusions of plants and other ingredients. Atomizers and nebulizers were developed in the mid-1800s in France and were thought to be an outgrowth of the perfume industry as well as a response to the fashion of inhaling thermal waters at spas. Around the turn of the 20th century, combustible powders and cigarettes containing stramonium were popular for asthma and other lung complaints. Following the discovery of the utility of epinephrine for treating asthma, hand-bulb nebulizers were developed, as well as early compressor nebulizers. The marketing of the first pressurized metered-dose inhaler for epinephrine and isoproterenol, by Riker Laboratories in 1956, was a milestone in the development of inhaled drugs. There have been remarkable advances in the technology of devices and formulations for inhaled drugs in the past 50 years. These have been influenced greatly by scientific developments in several areas: theoretical modeling and indirect measures of lung deposition, particle sizing techniques and in vitro deposition studies, scintigraphic deposition studies, pharmacokinetics and pharmacodynamics, and the 1987 Montreal Protocol, which banned chlorofluorocarbon propellants. We are now in an era of rapid technologic progress in inhaled drug delivery and applications of aerosol science, with the use of the aerosolized route for drugs for systemic therapy and for gene replacement therapy, use of aerosolized antimicrobials and immunosuppressants, and interest in specific targeting of inhaled drugs.

  10. Prototype particulate stack sampler with single-cut nozzle and microcomputer calculating/display system

    International Nuclear Information System (INIS)

    Eler, J.C.; Littlefield, L.G.; Tillery, M.I.

    1979-01-01

    A prototype particulate stack sampler (PPSS) has been developed to improve on the existing EPA Method 5 sampling apparatus. Its primary features are (1) higher sampling rate (56 1/min); (2) display (on demand) of all required variables and calculated values by a microcomputer-based calculating and display system; (3) continuous stack gas moisture determination; (4) a virtual impactor nozzle with 3 μm mass median diameter cutpoint which collects fine and coarse particle fractions on separate glass fiber filters; (5) a variable-area inlet to maintain isokinetic sampling conditions; and (6) conversion to stainless steel components from the glass specified by EPA Method 5. The basic sampling techniques of EPA Method 5 have been retained; however, versatility in the form of optional in-stack filters and general modernization of the stack sampler have been provided in the prototype design. Laboratory testing with monodisperse dye aerosols has shown the present variable inlet, virtual impactor nozzle to have a collection efficiency which is less than 77% and significant wall losses. This is primarily due to lack of symmetry in this rectangular jet impactor and short transition lengths dictated by physical design constraints (required passage of the nozzle through a 7.6 cm (3 in) diameter stack port). Electronic components have shown acceptable service in laboratory testing although no field testing of the prototype under a broad range of temperature, humidity, and SO 2 concentration has been undertaken

  11. Efficiency of Airborne Sample Analysis Platform (ASAP Bioaerosol Sampler for Pathogen Detection

    Directory of Open Access Journals (Sweden)

    Anurag eSharma

    2015-05-01

    Full Text Available The threat of bioterrorism and pandemics has highlighted the urgency for rapid and reliable bioaerosol detection in different environments. Safeguarding against such threats requires continuous sampling of the ambient air for pathogen detection. In this study we investigated the efficacy of the Airborne Sample Analysis Platform (ASAP 2800 bioaerosol sampler to collect representative samples of air and identify specific viruses suspended as bioaerosols. To test this concept, we aerosolized an innocuous replication-defective bovine adenovirus serotype 3 (BAdV3 in a controlled laboratory environment. The ASAP efficiently trapped the surrogate virus at 5×10E3 plaque-forming units (p.f.u. [2×10E5 genome copy equivalent] concentrations or more resulting in the successful detection of the virus using quantitative PCR. These results support the further development of ASAP for bioaerosol pathogen detection.

  12. Distribution and retention of inhaled selenium compounds in the rat

    International Nuclear Information System (INIS)

    Burkstaller, M.A.; Cuddihy, R.G.

    1978-01-01

    Selenium containing compounds released into the atmosphere during coal combustion are principally of the elemental form or the dioxide. These compounds differ greatly in their chemical properties. Fischer-344 rats were exposed via inhalation to both the dioxide and the red elemental form of selenium. Subsequently, measurements were made of internal absorption, organ distribution and retention, and modes of excretion. A radiotracer, 75 Se, was incorporated into the aerosol to facilitate these measurements. Retention of both aerosols in the total body showed long term components with half lives of 43 and 15 days accounting for 25 to 35% of the initially deposited selenium. Excretion occurred principally by way of urine. For both aerosols, selenium absorbed into the systemic circulation was mainly found in the liver, kidney, blood, gastrointestinal tract and bone

  13. Aerosols concentration in the Candiota area applying different gravimetric methods of sampling and numeric modelling.

    Science.gov (United States)

    Braga, C F; Alves, R C M; Teixeira, E C; Pire, M

    2002-12-01

    The main purpose of the present work is to study the concentration of atmospheric particles in the Candiota region, in the state of Rio Grande do Sul, where the Presidente Médici coal power plant is located. Aerosol samples were collected at the studied locations between December 2000 and December 2001 during 24 h periods at 15 day intervals using HV PM10 and dichotomous samplers. Then, the values obtained with the ISCST (Industrial Source Complex Term) model, with the HV PM10 sampler at all studied stations, and with the dichotomous sampler at the 8 de Agosto station were compared with each other. The results show that the values for the model had been underestimated in relation to the HV PM10 data for the studied stations, but agreed with the values obtained with the dichotomous sampler.

  14. Characterization of aerosols produced by surgical procedures

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, H.C.; Muggenburg, B.A.; Lundgren, D.L.; Guilmette, R.A.; Snipes, M.B.; Jones, R.K. [Inhalation Toxicology Research Institute, Albuquerque, NM (United States); Turner, R.S. [Lovelace Health Systems, Albuquerque, NM (United States)

    1994-07-01

    In many surgeries, especially orthopedic procedures, power tools such as saws and drills are used. These tools may produce aerosolized blood and other biological material from bone and soft tissues. Surgical lasers and electrocautery tools can also produce aerosols when tissues are vaporized and condensed. Studies have been reported in the literature concerning production of aerosols during surgery, and some of these aerosols may contain infectious material. Garden et al. (1988) reported the presence of papilloma virus DNA in the fumes produced from laser surgery, but the infectivity of the aerosol was not assessed. Moon and Nininger (1989) measured the size distribution and production rate of emissions from laser surgery and found that particles were generally less than 0.5 {mu}m diameter. More recently there has been concern expressed over the production of aerosolized blood during surgical procedures that require power tools. In an in vitro study, the production of an aerosol containing the human immunodeficiency virus (HIV) was reported when power tools were used to cut tissues with blood infected with HIV. Another study measured the size distribution of blood aerosols produced by surgical power tools and found blood-containing particles in a number of size ranges. Health care workers are anxious and concerned about whether surgically produced aerosols are inspirable and can contain viable pathogens such as HIV. Other pathogens such as hepatitis B virus (HBV) are also of concern. The Occupational Safety and Health funded a project at the National Institute for Inhalation Toxicology Research Institute to assess the extent of aerosolization of blood and other tissues during surgical procedures. This document reports details of the experimental and sampling approach, methods, analyses, and results on potential production of blood-associated aerosols from surgical procedures in the laboratory and in the hospital surgical suite.

  15. Evaluation of air samplers and filter materials for collection and recovery of airborne norovirus

    DEFF Research Database (Denmark)

    Uhrbrand, Katrine; Kalevi Koponen, Ismo; Schultz, Anna Charlotte

    2017-01-01

    V. Sampling was performed using a nylon (NY) filter in conjunction with four kinds of personal samplers; Gesamtstaubprobenahme sampler (GSP), Triplex-cyclone sampler (TC), 3-piece closed-faced Millipore cassette (3P) and a 2-stage NIOSH cyclone sampler (NIO). In addition, sampling was performed using the GSP...

  16. Food hypersensitivity by inhalation

    Directory of Open Access Journals (Sweden)

    Bahna Sami L

    2009-02-01

    Full Text Available Abstract Though not widely recognized, food hypersensitivity by inhalation can cause major morbidity in affected individuals. The exposure is usually more obvious and often substantial in occupational environments but frequently occurs in non-occupational settings, such as homes, schools, restaurants, grocery stores, and commercial flights. The exposure can be trivial, as in mere smelling or being in the vicinity of the food. The clinical manifestations can vary from a benign respiratory or cutaneous reaction to a systemic one that can be life-threatening. In addition to strict avoidance, such highly-sensitive subjects should carry self-injectable epinephrine and wear MedicAlert® identification. Asthma is a strong predisposing factor and should be well-controlled. It is of great significance that food inhalation can cause de novo sensitization.

  17. Inhalation of uranium ores

    International Nuclear Information System (INIS)

    Stuart, B.O.; Jackson, P.O.

    1975-01-01

    In previous studies the biological dispositions of individual long-lived alpha members of the uranium chain ( 238 U, 234 U and 230 Th) were determined during and following repeated inhalation exposures of rats to pitchblende (26 percent U 3 O 8 ) ore. Although finely dispersed ore in secular equilibrium was inhaled, 230 Th/ 234 U radioactivity ratios in the lungs rose from 1.0 to 2.5 during 8 weeks of exposures and increased to 9.2 by four months after cessation of exposures. Marked non-equilibrium levels were also found in the tracheobronchial lymph nodes, kidneys, liver, and femur. Daily exposures of beagle dogs to high levels of this ore for 8 days resulted in lung 230 Th/ 234 U ratios of >2.0. Daily exposures of dogs to lower levels (0.1 mg/1) for 6 months, with sacrifice 15 months later, resulted in lung and thoracic lymph node 230 Th/ 234 U ratios ranging from 3.6 to 9 and nearly 7, respectively. The lungs of hamsters exposed to carnotite (4 percent U 3 O 8 ) ore in current lifespan studies show 230 Th/ 234 U ratios as high as 2.0 during daily inhalation of this ore in secular equilibrium. Beagle dogs sacrificed after several years of daily inhalations of the same carnotite ore plus radon daughters also showed marked non-equilibrium ratios of 230 Th/ 234 U, ranging from 5.6 to 7.4 in lungs and 6.2 to 9.1 in thoracic lymph nodes. This pattern of higher retention of 230 Th than 234 U in lungs, thoracic lymph nodes, and other tissues is thus consistent for two types of uranium ore among several species and suggests a reevaluation of maximum permissible air concentrations of ore, currently based only on uranium content

  18. Inhaled transuranics in rodents

    International Nuclear Information System (INIS)

    Sanders, C.L.

    1983-01-01

    This project examines the interactions of external and internal radiation from mixtures of radionuclides present within the nuclear fuel inventory. The objective of the project is to evaluate the effects of mixed radiation insults, using key radiation sources as indicative of overall processes that may occur following release of nuclear fuel into the air. Previously initiated studies of immunological effects of plutonium inhalation are also being completed as part of this project

  19. Pathology associated with inhaled plutonium in beagles

    International Nuclear Information System (INIS)

    Dagle, G.E.; Park, J.F.; Weller, R.E.; Ragan, H.A.; Stevens, D.L.

    1986-01-01

    The pathology associated with the inhalation of plutonium was studied in beagle dogs given a single exposure to aerosols of 239 PuO 2 , 238 PuO 2 , or 239 Pu(NO 3 ) 4 . The temporal-spatial relationships between plutonium deposition and the development of lesions in dogs were evaluated up to 11 years, 8 years, or 5 years, respectively, after exposures, resulting in initial lung burdens ranging from ∼2 to ∼5500 nCi. Exposure of the lung to high dose levels produced a spectrum of progressively more severe morphological changes, ranging from radiation pneumonitis to fibrosis. Lung tumors occurred at exposure levels that did not result in early death from radiation pneumonitis or fibrosis. Bronchiolar-alveolar carcinomas, papillary adenocarcinomas, epidermoid carcinomas, and combined epidermoid and adenocarcinomas were observed. Sclerosing tracheobronchial lymphadenitis, radiation osteodystrophy, osteosarcoma, and hepatic adenomatous hyperplasia were the principal extrapulmonary lesions resulting from translocation of plutonium. 15 refs., 2 tabs

  20. DTPA therapy of lung contaminations: testing a self contained aerosol generator

    International Nuclear Information System (INIS)

    Ducousso, R.; Pasquier, C.

    1975-01-01

    It has been shown how much the effectiveness of DTPA therapy of respiratory contamination decreased when the delay of administration of the product increased. Moreover, the effectiveness of local administration of the chelating agent as aerosol has been widely recognized. Owing to both the therapeutic urgency and the local administration, an individual pocket apparatus allowing emergency DTPA inhalation, on the spot of the accident was tried. A turbo-inhalator sold for the administration of an anti-asthmatic powder was tested, using DTPA powder inhaled by a volunteer previously contaminated by a 140 LaCl 3 aerosol [fr

  1. Secondary aerosols from power plant effluents: delivery and in vivo detection systems

    International Nuclear Information System (INIS)

    Parks, N.J.; Raabe, O.G.; Bradley, E.; Raub, J.

    1976-01-01

    An experimental system is described for the generation of radiolabeled monodisperse aerosols, which are physico-chemically analogous to aerosols produced as secondary products of gaseous fossil fuel power plant emissions of SO 2 and NO 2 . The experimental system for inhalation exposure of non-human primates to these particles and the in vivo determination of systemic distribution and target organs is discussed

  2. Protection of air in premises and environment against beryllium aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Bitkolov, N.Z.; Vishnevsky, E.P.; Krupkin, A.V. [Research Inst. of Industrial and Marine Medicine, St. Petersburg (Russian Federation)

    1998-01-01

    First and foremost, the danger of beryllium aerosols concerns a possibility of their inhalation. The situation is aggravated with high biological activity of the beryllium in a human lung. The small allowable beryllium aerosols` concentration in air poses a rather complex and expensive problem of the pollution prevention and clearing up of air. The delivery and transportation of beryllium aerosols from sites of their formation are defined by the circuit of ventilation, that forms aerodynamics of air flows in premises, and aerodynamic links between premises. The causes of aerosols release in air of premises from hoods, isolated and hermetically sealed vessels can be vibrations, as well as pulses of temperature and pressure. Furthermore, it is possible the redispersion of aerosols from dirty surfaces. The effective protection of air against beryllium aerosols at industrial plants is provided by a complex of hygienic measures: from individual means of breath protection up to collective means of the prevention of air pollution. (J.P.N.)

  3. Automated particulate sampler field test model operations guide

    Energy Technology Data Exchange (ETDEWEB)

    Bowyer, S.M.; Miley, H.S.

    1996-10-01

    The Automated Particulate Sampler Field Test Model Operations Guide is a collection of documents which provides a complete picture of the Automated Particulate Sampler (APS) and the Field Test in which it was evaluated. The Pacific Northwest National Laboratory (PNNL) Automated Particulate Sampler was developed for the purpose of radionuclide particulate monitoring for use under the Comprehensive Test Ban Treaty (CTBT). Its design was directed by anticipated requirements of small size, low power consumption, low noise level, fully automatic operation, and most predominantly the sensitivity requirements of the Conference on Disarmament Working Paper 224 (CDWP224). This guide is intended to serve as both a reference document for the APS and to provide detailed instructions on how to operate the sampler. This document provides a complete description of the APS Field Test Model and all the activity related to its evaluation and progression.

  4. Europa Drum Sampler (EDuS), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The main objective of the proposed work is to develop a robust and effective sample acquisition system for the Europa lander called the Europa Drum Sampler (EDuS)....

  5. Generation of aerosols: BARC nebulizer and others

    International Nuclear Information System (INIS)

    Soni, P.S.; Raghunath, B.

    1994-01-01

    The concern with atmospheric pollution in recent times has focused attention on aerosols, their distribution pattern after inhalation and the kinetics of their deposition and exclusion from bronchial passages. The technique of radioaerosols for lung imaging is of recent origin. The procedure was proposed as a means of estimating regional ventilation and localizing areas of airway narrowing. The technique is an alternative in the face of non-availability of radioactive gases, especially in developing countries where the cost is the major factor due to economic reasons. Now, it is beyond doubt that radioaerosol lung studies are a potentially valuable tool in the evaluation of respiratory function in health and disease, especially to detect chronic obstructive pulmonary diseases. Also, the administration of a drug by aerosol inhalation provides a convenient method for the treatment of conditions affecting the respiratory system. This write-up will brief us about radioaerosol, its generation and characterisation

  6. Generation of aerosols: BARC nebulizer and others

    Energy Technology Data Exchange (ETDEWEB)

    Soni, P S; Raghunath, B

    1994-07-01

    The concern with atmospheric pollution in recent times has focused attention on aerosols, their distribution pattern after inhalation and the kinetics of their deposition and exclusion from bronchial passages. The technique of radioaerosols for lung imaging is of recent origin. The procedure was proposed as a means of estimating regional ventilation and localizing areas of airway narrowing. The technique is an alternative in the face of non-availability of radioactive gases, especially in developing countries where the cost is the major factor due to economic reasons. Now, it is beyond doubt that radioaerosol lung studies are a potentially valuable tool in the evaluation of respiratory function in health and disease, especially to detect chronic obstructive pulmonary diseases. Also, the administration of a drug by aerosol inhalation provides a convenient method for the treatment of conditions affecting the respiratory system. This write-up will brief us about radioaerosol, its generation and characterisation.

  7. Development and comparison of new high-efficiency dry powder inhalers for carrier-free formulations.

    Science.gov (United States)

    Behara, Srinivas R B; Longest, P Worth; Farkas, Dale R; Hindle, Michael

    2014-02-01

    High-efficiency dry powder inhalers (DPIs) were developed and tested for use with carrier-free formulations across a range of different inhalation flow rates. Performance of a previously reported DPI was compared with two new designs in terms of emitted dose (ED) and aerosolization characteristics using in vitro experiments. The two new designs oriented the capsule chamber (CC) at different angles to the main flow passage, which contained a three-dimensional (3D) rod array for aerosol deaggregation. Computational fluid dynamics simulations of a previously developed deaggregation parameter, the nondimensional specific dissipation (NDSD), were used to explain device performance. Orienting the CC at 90° to the mouthpiece, the CC90 -3D inhaler provided the best performance with an ED = 73.4%, fine particle fractions (FPFs) less than 5 and 1 μm of 95.1% and 31.4%, respectively, and a mass median aerodynamic diameter (MMAD) = 1.5 μm. For the carrier-free formulation, deaggregation was primarily influenced by capsule aperture position and the NDSD parameter. The new CC-3D inhalers reduced the percent difference in FPF and MMAD between low and high flows by 1-2 orders of magnitude compared with current commercial devices. In conclusion, the new CC-3D inhalers produced extremely high-quality aerosols with little sensitivity to flow rate and are expected to deliver approximately 95% of the ED to the lungs. © 2013 Wiley Periodicals, Inc. and the American Pharmacists Association.

  8. Recent advances in delivery mechanisms for aerosol therapy during pediatric respiratory diseases.

    Science.gov (United States)

    Wu, Yue'E; Zhang, Chonglin; Zhen, Qing

    2018-04-01

    The treatment of pediatric surgery diseases via utilization of aerosol delivery mechanisms is in progress for the betterment of pediatric care. Over the years, aerosol therapy has come to play an integral role in the treatment of pediatric respiratory diseases. Inhaled aerosol agents such as bronchodilators, corticosteroids, antibiotics, and mucolytics are commonly delivered to spontaneously breathing pediatric patients with a tracheostomy. Administering therapeutic inhaled aerosols to pediatric patients is challenging. The pediatric population ranges in age, which means patients with different airway sizes, breathing patterns, and cooperation levels. These patient-related factors impact the deposition of aerosol drugs in the lungs. The present review article will discuss the recent advancements in the delivery mechanisms for aerosol therapy in pediatric patients with respiratory diseases.

  9. Hematologic effects of inhaled plutonium in beagles

    International Nuclear Information System (INIS)

    Ragan, H.A.; Buschbom, R.L.; Park, J.F.; Dagle, G.E.; Weller, R.E.

    1986-01-01

    Beagle dogs were exposed, by inhalation, 5 to 11 years ago, to aerosols of 239 PuO 2 , 238 PuO 2 , or 239 Pu(NO 3 ) 4 , at six dose levels resulting in initial lung burdens ranging from ∼2 to ∼5500 nCi. Translocation of the plutonium to extrapulmonary sites was related to the physical-chemical characteristics of the plutonium compound. The highly insoluble 239 PuO 2 was retained primarily in the lung and associated lymph nodes, whereas 239 Pu(NO 3 ) 4 was much more soluble and translocated relatively rapidly to the skeleton and other extrapulmonary tissues. The 238 PuO 2 was intermediate in solubility and translocation characteristics. The hematologic effects of plutonium inhalation were most pronounced on lymphocyte populations. Evidence suggests that these effects result from irradiation of lymphocytes via the pulmonary lymph nodes with insoluble 239 PuO 2 , and via these same lymph nodes, extrapulmonary lymph nodes, and bone marrow lymphocytes with the more soluble forms, i.e., 238 PuO 2 and 239 Pu(NO 3 ) 4 . There is no evidence suggesting that these exposures increase the risk of developing myeloid or lymphoid neoplasia. 8 refs., 4 figs., 3 tabs

  10. Radiation dose to the lungs due to inhalation of alpha emitters

    International Nuclear Information System (INIS)

    Haque, A.K.M.M.; Al-Affan, I.A.M.

    1987-01-01

    The radiation dose to the lungs due to inhalation of radon daughters has been computed with improved data on lung models, aerosol parameters, deposition and clearance mechanisms. The dose corresponds to mean radon concentration of 23 Bq/m 3 indoors (recent NRPB Survey) for different living conditions. The dose rate to basal cells in gen. 5 is 12 mGy/WLM. (author)

  11. Bio-mathematical models for radon daughters inhalation. The ModeLung software

    International Nuclear Information System (INIS)

    Tomulescu, Vlad C.; Rusu, Mircea

    2002-01-01

    Radon and its decay daughters are the most important sources for natural irradiation of population. ModeLung software is based on the human respiratory tract compartment model and is computing radiation doses on several internal organs and tissues for subjects inhaling radon daughters attached to aerosols. Radiation doses are presented for several subjects performing different types of activity under specific environmental conditions. (authors)

  12. Systemic activity of inhaled topical steroid in toddlers studied by knemometry

    DEFF Research Database (Denmark)

    Bisgaard, H

    1993-01-01

    of four weeks with placebo or budesonide in daily doses of 200 micrograms and 800 micrograms administered as a pressurized aerosol inhaled via a spacer with a face mask. Twenty-nine percent (median) of the nominal dose was delivered at the mouth of the children. Three children were withdrawn because...

  13. Aerosol chemistry over a high altitude station at northeastern Himalayas, India.

    Directory of Open Access Journals (Sweden)

    Abhijit Chatterjee

    Full Text Available BACKGROUND: There is an urgent need for an improved understanding of the sources, distributions and properties of atmospheric aerosol in order to control the atmospheric pollution over northeastern Himalayas where rising anthropogenic interferences from rapid urbanization and development is becoming an increasing concern. METHODOLOGY/PRINCIPAL FINDINGS: An extensive aerosol sampling program was conducted in Darjeeling (altitude approximately 2200 meter above sea level (masl, latitude 27 degrees 01'N and longitude 88 degrees 15'E, a high altitude station in northeastern Himalayas, during January-December 2005. Samples were collected using a respirable dust sampler and a fine dust sampler simultaneously. Ion chromatograph was used to analyze the water soluble ionic species of aerosol. The average concentrations of fine and coarse mode aerosol were found to be 29.5+/-20.8 microg m(-3 and 19.6+/-11.1 microg m(-3 respectively. Fine mode aerosol dominated during dry seasons and coarse mode aerosol dominated during monsoon. Nitrate existed as NH(4NO(3 in fine mode aerosol during winter and as NaNO(3 in coarse mode aerosol during monsoon. Gas phase photochemical oxidation of SO(2 during premonsoon and aqueous phase oxidation during winter and postmonsoon were the major pathways for the formation of SO(4(2- in the atmosphere. Long range transport of dust aerosol from arid regions of western India was observed during premonsoon. The acidity of fine mode aerosol was higher in dry seasons compared to monsoon whereas the coarse mode acidity was higher in monsoon compared to dry seasons. Biomass burning, vehicular emissions and dust particles were the major types of aerosol from local and continental regions whereas sea salt particles were the major types of aerosol from marine source regions. CONCLUSIONS/SIGNIFICANCE: The year-long data presented in this paper provide substantial improvements to the heretofore poor knowledge regarding aerosol chemistry over

  14. Aerosol chemistry over a high altitude station at northeastern Himalayas, India.

    Science.gov (United States)

    Chatterjee, Abhijit; Adak, Anandamay; Singh, Ajay K; Srivastava, Manoj K; Ghosh, Sanjay K; Tiwari, Suresh; Devara, Panuganti C S; Raha, Sibaji

    2010-06-16

    There is an urgent need for an improved understanding of the sources, distributions and properties of atmospheric aerosol in order to control the atmospheric pollution over northeastern Himalayas where rising anthropogenic interferences from rapid urbanization and development is becoming an increasing concern. An extensive aerosol sampling program was conducted in Darjeeling (altitude approximately 2200 meter above sea level (masl), latitude 27 degrees 01'N and longitude 88 degrees 15'E), a high altitude station in northeastern Himalayas, during January-December 2005. Samples were collected using a respirable dust sampler and a fine dust sampler simultaneously. Ion chromatograph was used to analyze the water soluble ionic species of aerosol. The average concentrations of fine and coarse mode aerosol were found to be 29.5+/-20.8 microg m(-3) and 19.6+/-11.1 microg m(-3) respectively. Fine mode aerosol dominated during dry seasons and coarse mode aerosol dominated during monsoon. Nitrate existed as NH(4)NO(3) in fine mode aerosol during winter and as NaNO(3) in coarse mode aerosol during monsoon. Gas phase photochemical oxidation of SO(2) during premonsoon and aqueous phase oxidation during winter and postmonsoon were the major pathways for the formation of SO(4)(2-) in the atmosphere. Long range transport of dust aerosol from arid regions of western India was observed during premonsoon. The acidity of fine mode aerosol was higher in dry seasons compared to monsoon whereas the coarse mode acidity was higher in monsoon compared to dry seasons. Biomass burning, vehicular emissions and dust particles were the major types of aerosol from local and continental regions whereas sea salt particles were the major types of aerosol from marine source regions. The year-long data presented in this paper provide substantial improvements to the heretofore poor knowledge regarding aerosol chemistry over northeastern Himalayas, and should be useful to policy makers in making control

  15. Pesticide monitoring in surface water and groundwater using passive samplers

    Science.gov (United States)

    Kodes, V.; Grabic, R.

    2009-04-01

    Passive samplers as screening devices have been used within a czech national water quality monitoring network since 2002 (SPMD and DGT samplers for non polar substances and metals). The passive sampler monitoring of surface water was extended to polar substances, in 2005. Pesticide and pharmaceutical POCIS samplers have been exposed in surface water at 21 locations and analysed for polar pesticides, perfluorinated compounds, personal care products and pharmaceuticals. Pesticide POCIS samplers in groundwater were exposed at 5 locations and analysed for polar pesticides. The following active substances of plant protection products were analyzed in surface water and groundwater using LC/MS/MS: 2,4,5-T, 2,4-D, Acetochlor, Alachlor, Atrazine, Atrazine_desethyl, Azoxystrobin, Bentazone, Bromacil, Bromoxynil, Carbofuran, Clopyralid, Cyanazin, Desmetryn, Diazinon, Dicamba, Dichlobenil, Dichlorprop, Dimethoat, Diuron, Ethofumesate, Fenarimol, Fenhexamid, Fipronil, Fluazifop-p-butyl, Hexazinone, Chlorbromuron, Chlorotoluron, Imazethapyr, Isoproturon, Kresoxim-methyl, Linuron, MCPA, MCPP, Metalaxyl, Metamitron, Methabenzthiazuron, Methamidophos, Methidathion, Metobromuron, Metolachlor, Metoxuron, Metribuzin, Monolinuron, Nicosulfuron, Phorate, Phosalone, Phosphamidon, Prometryn, Propiconazole, Propyzamide, Pyridate, Rimsulfuron, Simazine, Tebuconazole, Terbuthylazine, Terbutryn, Thifensulfuron-methyl, Thiophanate-methyl and Tri-allate. The POCIS samplers performed very well being able to provide better picture than grab samples. The results show that polar pesticides and also perfluorinated compounds, personal care products and pharmaceuticals as well occur in hydrosphere of the Czech republic. Acknowledgment: Authors acknowledge the financial support of grant No. 2B06095 by the Ministry of Education, Youth and Sports.

  16. Solubility of plutonium dioxide aerosols, in vitro

    International Nuclear Information System (INIS)

    Newton, G.J.; Kanapilly, G.M.

    1976-01-01

    Solubility of plutonium aerosols is an important parameter in establishing risk estimates for industrial workers who might accidentally inhale these materials and in evaluating environmental health impacts associated with Pu. In vitro solubility of industrial plutonium aerosols in a simulated lung fluid is compared to similar studies with ultrafine aerosols from laser ignition of delta phase plutonium metal and laboratory-produced spherical particles of 238 PuO 2 and 239 PuO 2 . Although relatively insoluble, industrial plutonium-mixed oxide aerosols were much more soluble than laboratory-produced plutonium dioxide particles. Chain agglomerate aerosols from laser ignition of metallic Pu indicated in vitro dissolution half-times of 10 and 50 days for activity median aerodynamic diameter (AMAD) of 0.7 and 2.3 μm, respectively. Plutonium-containing mixed oxide aerosols indicated dissolution half-times of 40 to 500 days for particles formed by industrial powder comminution and blending. Centerless grinding of fuel pellets yielded plutonium-containing aerosols with dissolution half-times of 1200 to 8000 days. All mixed oxide particles were in the size range 1.0 μm to 2.5 μm AMAD

  17. Transient digitizer with displacement current samplers

    Science.gov (United States)

    McEwan, Thomas E.

    1996-01-01

    A low component count, high speed sample gate, and digitizer architecture using the sample gates is based on use of a signal transmission line, a strobe transmission line and a plurality of sample gates connected to the sample transmission line at a plurality of positions. The sample gates include a strobe pickoff structure near the strobe transmission line which generates a charge displacement current in response to propagation of the strobe signal on the strobe transmission line sufficient to trigger the sample gate. The sample gate comprises a two-diode sampling bridge and is connected to a meandered signal transmission line at one end and to a charge-holding cap at the other. The common cathodes are reverse biased. A voltage step is propagated down the strobe transmission line. As the step propagates past a capacitive pickoff, displacement current i=c(dv/dT), flows into the cathodes, driving the bridge into conduction and thereby charging the charge-holding capacitor to a value related to the signal. A charge amplifier converts the charge on the charge-holding capacitor to an output voltage. The sampler is mounted on a printed circuit board, and the sample transmission line and strobe transmission line comprise coplanar microstrips formed on a surface of the substrate. Also, the strobe pickoff structure may comprise a planar pad adjacent the strobe transmission line on the printed circuit board.

  18. Aerosol Sampling System for Collection of Capstone Depleted Uranium Particles in a High-Energy Environment

    International Nuclear Information System (INIS)

    Holmes, Thomas D.; Guilmette, Raymond A.; Cheng, Yung-Sung; Parkhurst, MaryAnn; Hoover, Mark D.

    2009-01-01

    The Capstone Depleted Uranium Aerosol Study was undertaken to obtain aerosol samples resulting from a kinetic-energy cartridge with a large-caliber depleted uranium (DU) penetrator striking an Abrams or Bradley test vehicle. The sampling strategy was designed to (1) optimize the performance of the samplers and maintain their integrity in the extreme environment created during perforation of an armored vehicle by a DU penetrator, (2) collect aerosols as a function of time post-impact, and (3) obtain size-classified samples for analysis of chemical composition, particle morphology, and solubility in lung fluid. This paper describes the experimental setup and sampling methodologies used to achieve these objectives. Custom-designed arrays of sampling heads were secured to the inside of the target in locations approximating the breathing zones of the vehicle commander, loader, gunner, and driver. Each array was designed to support nine filter cassettes and nine cascade impactors mounted with quick-disconnect fittings. Shielding and sampler placement strategies were used to minimize sampler loss caused by the penetrator impact and the resulting fragments of eroded penetrator and perforated armor. A cyclone train was used to collect larger quantities of DU aerosol for chemical composition and solubility. A moving filter sample was used to obtain semicontinuous samples for depleted uranium concentration determination. Control for the air samplers was provided by five remotely located valve control and pressure monitoring units located inside and around the test vehicle. These units were connected to a computer interface chassis and controlled using a customized LabVIEW engineering computer control program. The aerosol sampling arrays and control systems for the Capstone study provided the needed aerosol samples for physicochemical analysis, and the resultant data were used for risk assessment of exposure to DU aerosol

  19. Characterization of a nose-only inhalation exposure system for hydrocarbon mixtures and jet fuels.

    Science.gov (United States)

    Martin, Sheppard A; Tremblay, Raphael T; Brunson, Kristyn F; Kendrick, Christine; Fisher, Jeffrey W

    2010-04-01

    A directed-flow nose-only inhalation exposure system was constructed to support development of physiologically based pharmacokinetic (PBPK) models for complex hydrocarbon mixtures, such as jet fuels. Due to the complex nature of the aerosol and vapor-phase hydrocarbon exposures, care was taken to investigate the chamber hydrocarbon stability, vapor and aerosol droplet compositions, and droplet size distribution. Two-generation systems for aerosolizing fuel and hydrocarbons were compared and characterized for use with either jet fuels or a simple mixture of eight hydrocarbons. Total hydrocarbon concentration was monitored via online gas chromatography (GC). Aerosol/vapor (A/V) ratios, and total and individual hydrocarbon concentrations, were determined using adsorbent tubes analyzed by thermal desorption-gas chromatography-mass spectrometry (TDS-GC-MS). Droplet size distribution was assessed via seven-stage cascade impactor. Droplet mass median aerodynamic diameter (MMAD) was between 1 and 3 mum, depending on the generator and mixture utilized. A/V hydrocarbon concentrations ranged from approximately 200 to 1300 mg/m(3), with between 20% and 80% aerosol content, depending on the mixture. The aerosolized hydrocarbon mixtures remained stable during the 4-h exposure periods, with coefficients of variation (CV) of less than 10% for the total hydrocarbon concentrations. There was greater variability in the measurement of individual hydrocarbons in the A-V phase. In conclusion, modern analytical chemistry instruments allow for improved descriptions of inhalation exposures of rodents to aerosolized fuel.

  20. Minimizing variability of cascade impaction measurements in inhalers and nebulizers.

    Science.gov (United States)

    Bonam, Matthew; Christopher, David; Cipolla, David; Donovan, Brent; Goodwin, David; Holmes, Susan; Lyapustina, Svetlana; Mitchell, Jolyon; Nichols, Steve; Pettersson, Gunilla; Quale, Chris; Rao, Nagaraja; Singh, Dilraj; Tougas, Terrence; Van Oort, Mike; Walther, Bernd; Wyka, Bruce

    2008-01-01

    The purpose of this article is to catalogue in a systematic way the available information about factors that may influence the outcome and variability of cascade impactor (CI) measurements of pharmaceutical aerosols for inhalation, such as those obtained from metered dose inhalers (MDIs), dry powder inhalers (DPIs) or products for nebulization; and to suggest ways to minimize the influence of such factors. To accomplish this task, the authors constructed a cause-and-effect Ishikawa diagram for a CI measurement and considered the influence of each root cause based on industry experience and thorough literature review. The results illustrate the intricate network of underlying causes of CI variability, with the potential for several multi-way statistical interactions. It was also found that significantly more quantitative information exists about impactor-related causes than about operator-derived influences, the contribution of drug assay methodology and product-related causes, suggesting a need for further research in those areas. The understanding and awareness of all these factors should aid in the development of optimized CI methods and appropriate quality control measures for aerodynamic particle size distribution (APSD) of pharmaceutical aerosols, in line with the current regulatory initiatives involving quality-by-design (QbD).

  1. Early diagnosis of morphologic-functional changes of the airways by a simple method of inhalation scintigraphy

    International Nuclear Information System (INIS)

    Flierdt, E. van de; Bauer, R.; Laubenbacher, C.; Didic, M.; Langhammer, H.R.; Pabst, H.W.

    1992-01-01

    In order to validate a method of inhalation scintigraphy with 99m Tc-labeled human serum albumin in the early diagnosis of morphologic-functional changes of the airways 35 volunteers and patients (12 healthy non-smokers and smokers each, 11 patients with bronchitis) were studied. Deposition of the aerosol immediately after inhalation was calculated quantitatively by a ROI technique and qualitatively (scoring of central deposition, homogeneity, and recognizability of lung outline). Additionally, the regional clearance of the inhaled aerosol was determined by continuous lung imaging up to 60 min (mainly regional mucociliary removal rates). Discrimination between healthy volunteers and patients with bronchitis was possible by means of deposition patterns immediately after inhalation. On the other hand, no differences could be recognized in this way between healthy non-smokers and smokers. Regional mucociliary removal was higher in non-smokers than in smokers, but there was no difference between smokers and patients with bronchitis. (orig.) [de

  2. Carbonaceous Aerosol Characterization during 2016 KOR-US 2016

    Science.gov (United States)

    Rodriguez, B.; Santos, G. M.; Sanchez, D.; Jeong, D.; Czimczik, C. I.; Kim, S.

    2017-12-01

    Atmospheric carbonaceous aerosols are a major component of fine particulate matter and assume important roles in Earth's climate and human health. Because atmospheric carbonaceous aerosols exist as a continuum ranging from small, light-scattering organic carbon (OC), to highly-condensed, light-absorbing elemental carbon (EC) they have contrasting effects on interaction with incoming and outgoing radiation, cloud formation, and snow/ice albedo. By strengthening our understanding of the relative contribution and sources of OC and EC we will be able to further describe aerosol formation and mixing at the regional level. To understand the relative anthropogenic and biogenic contributions to carbonaceous aerosol, 12 PM10 aerosols samples were collected on quartz fiber filters at the Mt. Taewha Research Forest in South Korea during the KORUS-AQ 2016 campaign over periods of 24-48 hours with a high-volume air sampler. Analysis of bulk C and N concentrations and absorption properties of filter extracts interspersed with HYSPLIT model results indicated that continental outflow across the Yellow Sea in enriched in bulk nitrogen loading and enhanced bulk absorptive properties of the aerosols. Bulk radiocarbon analysis also indicated enriched values in all samples indicating contamination from a nuclear power plant or the combustion of biomedical waste nearby. Here, we aim to investigate further the chemical characterization of VOCs adsorbed unto the aerosol through TD-GC-TOFMS. With this dataset we aim to determine the relative contribution of anthropogenic and biogenic aerosols by utilizing specific chemical tracers for source apportionment.

  3. Evaluation of a radioactive aerosol surveillance system

    International Nuclear Information System (INIS)

    Scripsick, R.C.; Stafford, R.G.; Beckman, R.J.; Tillery, M.I.; Romero, P.O.

    Measurements of the dilution of air contaminants between worker breathing zone and area air samplers were made by releasing a test aerosol in a workroom equipped with an aerosol surveillance system. The data were used to evaluate performance, and suggest improvements in design of the workroom's alarming air monitor system. It was found that a breathing zone concentration of 960 times the maximum permissible concentration in air (MPC/sub a/) for a half-hour was required to trigger alarms of the existing monitoring system under some release conditions. Alternative air monitor placement, suggested from dilution measurements, would reduce this average triggering concentration to 354 MPC/sub a/. Deployment of additional air monitors could further reduce the average triggering concentration to 241 MPC/sub a/. The relation between number of monitors and triggering concentration was studied. No significant decrease in average triggering concentration was noted for arrays containing greater than five monitors

  4. Airborne radioactive contamination following aerosol ventilation studies

    International Nuclear Information System (INIS)

    Mackie, A.; Hart, G.C.; Ibbett, D.A.; Whitehead, R.J.S.

    1994-01-01

    Lung aerosol ventilation studies may be accompanied by airborne contamination, with subsequent surface contamination. Airborne contamination has been measured prior to, during and following 59 consecutive 99 Tc m -diethylenetriamine pentaacetate (DTPA) aerosol studies using a personal air sampler. Airborne contamination ranging between 0 and 20 330 kBq m -3 has been measured. Airborne contamination increases with degree of patient breathing difficulty. The effective dose equivalent (EDE) to staff from ingested activity has been calculated to be 0.3 μSv per study. This figure is supported by data from gamma camera images of a contaminated staff member. However, surface contamination measurements reveal that 60% of studies exceed maximum permissible contamination limits for the hands; 16% of studies exceed limits for controlled area surfaces. (author)

  5. Know How to Use Your Asthma Inhaler

    Medline Plus

    Full Text Available ... Controlling Tools for Control Triggers Indoors In the Workplace Outdoors Management Asthma Action Plan Flu Shots Inhalers ... inhaler with a spacer Your browser does not support iframes Using a metered dose inhaler with a ...

  6. Lung retention and metabolic fate of inhaled benzo(a)pyrene associated with diesel exhaust particles

    International Nuclear Information System (INIS)

    Sun, J.D.; Wolff, R.K.; Kanapilly, G.M.; McClellan, R.O.

    1984-01-01

    The effect of ultrafine, insoluble, carrier particles on the lung retention and metabolic fate of inhaled PAHs was investigated with a radiolabeled model PAH, [ 3 H]benzo(a)pyrene ( 3 H-BaP). Fischer-344 rats were exposed (30 min) by nose-only inhalation to 3 H-BaP adsorbed (approximately 0.1% by mass) onto diesel engine exhaust particles. The total mass concentration of these aerosols was 4-6 micrograms/liter of air with a mass median diameter of 0.14 micron. Lung clearance of the inhaled particle-associated 3 H radioactivity occurred in two phases. The initially rapid clearance of this inhaled radiolabel had a half-time of less than 1 hr. The second, long-term component of lung clearance had a half-time of 18 +/- 2 days and represented 50 +/- 2% of the 3 H radioactivity that had initially deposited in lungs. In contrast, previous inhalation studies with a pure 3 H-BaP aerosol showed that greater than 99% of the 3 H radioactivity deposited in lungs was cleared within 2 hr after exposure. By HPLC analysis, the majority of diesel soot-associated 3 H radioactivity retained in lungs was BaP (65-76%) with smaller amounts of BaP-phenol (13-17%) and BaP-quinone (5-18%) metabolites also being detected. No other metabolites of BaP were detected in lungs of exposed rats. Tissue distribution and excretion patterns of 3 H radioactivity were qualitatively similar to previous inhalation studies with 3 H-BaP coated Ga2O3 aerosols. These findings suggest that inhaled PAHs may be retained in lungs for a greater period of time when these compounds are associated with diesel engine exhaust particles. These results may have significant implications for the health risks that may be involved with human exposure to particle-associated organic pollutants

  7. Anti-Tuberculosis Bacteriophage D29 Delivery with a Vibrating Mesh Nebulizer, Jet Nebulizer, and Soft Mist Inhaler.

    Science.gov (United States)

    Carrigy, Nicholas B; Chang, Rachel Y; Leung, Sharon S Y; Harrison, Melissa; Petrova, Zaritza; Pope, Welkin H; Hatfull, Graham F; Britton, Warwick J; Chan, Hak-Kim; Sauvageau, Dominic; Finlay, Warren H; Vehring, Reinhard

    2017-10-01

    To compare titer reduction and delivery rate of active anti-tuberculosis bacteriophage (phage) D29 with three inhalation devices. Phage D29 lysate was amplified to a titer of 11.8 ± 0.3 log 10 (pfu/mL) and diluted 1:100 in isotonic saline. Filters captured the aerosolized saline D29 preparation emitted from three types of inhalation devices: 1) vibrating mesh nebulizer; 2) jet nebulizer; 3) soft mist inhaler. Full-plate plaque assays, performed in triplicate at multiple dilution levels with the surrogate host Mycobacterium smegmatis, were used to quantify phage titer. Respective titer reductions for the vibrating mesh nebulizer, jet nebulizer, and soft mist inhaler were 0.4 ± 0.1, 3.7 ± 0.1, and 0.6 ± 0.3 log 10 (pfu/mL). Active phage delivery rate was significantly greater (p pfu/min) than for the jet nebulizer (5.4x10 4  ± 1.3x10 4 pfu/min). The soft mist inhaler delivered 4.6x10 6  ± 2.0x10 6 pfu per 11.6 ± 1.6 μL ex-actuator dose. Delivering active phage requires a prudent choice of inhalation device. The jet nebulizer was not a good choice for aerosolizing phage D29 under the tested conditions, due to substantial titer reduction likely occurring during droplet production. The vibrating mesh nebulizer is recommended for animal inhalation studies requiring large amounts of D29 aerosol, whereas the soft mist inhaler may be useful for self-administration of D29 aerosol.

  8. Task plan for test of PRBT prototypic liquid sampler

    International Nuclear Information System (INIS)

    Jenkins, W.J.

    1992-01-01

    The primary objective of this task is to determine just how representative Precipitate Reactor Bottom Tank (PRBT) samples taken from the Hydragard trademark prototypic liquid sampler are of the in-tank contents and also to determine the homogeneity of the in-tank contents. This shall be accomplished by a statistical design study sampling plan for paired contrasts of the analysis results of samples taken from: (1) the Hydragard trademark prototypic liquid sampler paired with the more fundamental grab sampler at the lower elevation for the Hydragard trademark prototypic liquid sampler accuracy and (2) the grab sampler at the lower elevation paired with the grab sampler at the upper elevation for the in-tank homogeneity. These measurements are paired together to sharpen the contrast so that, as nearly as possible, only the conditions of the effect under study will differ between the two. This ''split-plot'' arrangement provides increased precision for the contrast under study by canceling out common extraneous effects, thereby enabling the detection of smaller effects. The secondary objective of the task is to determine the level of influence of the major contributors to the overall uncertainty in the sample preparation and measurement process. These major steps include: preparation method (H 2 SO 4 -HF Titanium dissolution); aliquoting and dilution within a dissolution; measurement and long-term behavior of the ICP and AA instruments, as monitored by the measurement of standards and blanks embedded within each block of samples for the measurement sequence. This sampling task, therefore, is mostly devoted to determining the sampler characteristics and is not intended to provide a comprehensive estimate of the overall uncertainty affecting DWPF sample analysis in routine operation

  9. Aerosol challenge of calves with Haemophilus somnus and Mycoplasma dispar

    DEFF Research Database (Denmark)

    Tegtmeier, C.; Angen, Øystein; Grell, S.N.

    2000-01-01

    The aim of the study was to examine the ability of Haemophilus somnus and Mycoplasma dispar to induce pneumonia in healthy calves under conditions closely resembling the supposed natural way of infection, viz, by inhalation of aerosol droplets containing the microorganisms. The infections were...

  10. Aerosol deposition in the upper airways of a child

    NARCIS (Netherlands)

    de Jongh, Franciscus H.C.; Rinkel, M.J.G.; Hoeijmakers, Hendrik Willem Marie

    2005-01-01

    In a small child, normally only a small amount of inhaled aerosol particles reaches the lungs because the majority deposits in the upper airways. In this study, the upper airways of a 9- month-old child, based on computed tomography (CT) data, are modeled to serve as input for a computational fluid

  11. Nasal inhalation of budesonide from a spacer in children with perennial rhinitis and asthma

    DEFF Research Database (Denmark)

    Pedersen, W; Hjuler, Inga Merete; Bisgaard, H

    1998-01-01

    and asthma inhaled budesonide through the nose from a pressurized aerosol, attached to a spacer device, in a double-blind, placebo-controlled, crossover study. Compared with placebo, budesonide treatment resulted in a significant reduction of nasal symptoms (Pasthma symptoms (P...The standard treatment of allergic rhinitis and asthma consists of topical corticosteroids administered intranasally and inhaled through the mouth. Although this therapy is highly effective, and side-effects are few and mild, it may be possible further to improve the therapeutic index and patient...... compliance with the treatment. In the present study, we evaluated a nasal inhalation system used for the simultaneous treatment of rhinitis and asthma. In principle, it results in an airway deposition of the corticosteroid similar to that of inhaled allergens. Twenty-four children with perennial rhinitis...

  12. The relative effectiveness of inhaled alpha- and beta-emitting radionuclides in producing lung cancer

    International Nuclear Information System (INIS)

    Boecker, B.B.; Hahn, F.F.; Muggenburg, B.A.; Guilmetter, R.A.; Griffith, W.C.; McClellan, R.O.

    1988-01-01

    Proper assessment of a long-term human health risks associated with inhaled radionuclides requires knowledge of dose to critical cells and tissues and relationships between dose and effect for different biological end points. Results from epidemiological studies of exposed human populations provided important information for such assessments. However, because the types of exposures are limited, these results need to be supplemented with more detailed information on dosimetry and biological effects available through studies in laboratory animals and in vitro systems. To provide health risk information for inhaled fission product and actinide aerosols, life-span studies are being conducted using beagle dogs and other species at the Lovelace Inhalation Toxicology Research Institute (ITRI). Results of two life-span studies in dogs involving inhalation of the beta emitter 91 Y in fused aluminosilicate particles or the alpha emitter 239 PuO 2 are reported here

  13. Radiation dose estimates and hazard evaluations for inhaled airborne radionuclides. Annual progress report, July 1980-June 1981

    International Nuclear Information System (INIS)

    Mewhinney, J.A.

    1982-04-01

    The objective of this project is to conduct confirmatory research on aerosol characteristics and the resulting radiation dose distribution in animals following inhalation and to provide prediction of health consequences in humans due to airborne radioactivity which might be released in normal operations or under accident conditions during production of nuclear fuel composed of mixed oxides of U and Pu. Four research reports summarize the results of specific areas of research being conducted. The first presents final results for several types of physical chemical characterization accomplished on samples of aerosols collected at an industrial facility during normal fabrication of mixed oxide fuel. Many of these characterizations were also done on aerosol samples collected during animal inhalation exposure procedures for biological studies using these aerosol materials. The second paper reports on the methods development process used for establishing a capability for measurement of the specific surface area of aerosols, an important determinant in the rate of dissolution of particulates deposited in lung. The third paper provides updated information on the retention, distribution and excretion of Pu after inhalation by Beagles of aerosols of either 750 0 C treated UO 2 + PuO 2 , 1750 0 C treated (U,Pu)O 2 or 850 0 C treated pure PuO 2 . This paper also reports the results of the formulation of a biomathematical model useful in describing the results of these three inhalation studies. The fourth paper describes the early results from two studies in which Fischer-344 rats received inhalation exposure to aerosols of (U,Pu)O 2 or pure PuO 2 to determine the relationship of radiation dose to biological response

  14. Bio aerosol Generation at wastewater treatment plants: Identification of main bio aerosols sources

    International Nuclear Information System (INIS)

    Sanchez Monedero, M. A.; Aguilar, M. I.; Fenoll, R.; Roig, A.

    2009-01-01

    Typical operations taking place at wastewater treatment plants, especially those involving aeration and mechanical agitation of raw wastewater, represent one of the main sources of bio aerosols that, if inhaled, could pose a biologic hazard to site workers and local residents. Six different wastewater treatment plants from southeast Spain were monitories in order to identify the main bio aerosol sources and to evaluate the airborne microorganisms levels to which workers may be exposed to. Air samples were taken from selected locations by using a single stage impactor. (Author)

  15. Toxicity of inhaled alpha-emitting radionuclides - Status report

    Energy Technology Data Exchange (ETDEWEB)

    Muggenburg, B A; Mewhinney, J A; Guilmette, R A; Gillett, N A; Diel, J H; Lundgren, D L; Hahn, F F; Boecker, B B; McClellan, R O

    1988-12-01

    The toxicity of inhaled alpha-emitting radionuclides is being investigated in a series of interrelated dose-response studies. Dogs, rodents, and nonhuman primates have been exposed to monodisperse or polydisperse aerosols of the oxides of {sup 239}Pu, {sup 238}Pu, {sup 241}Am, or {sup 244}Cm to measure the relative importance of average organ dose, local dose around particles, specific activity, chemical form, particle size, and number of particles inhaled to the development of biological effects. The influence of animal species, age at exposure, and pre-existing lung disease, as well as the effects of repeated exposure, are also being studied, because they may influence the toxicity of these radionuclides. (author)

  16. Lung cancer and inhaled uranium ore dust in rats

    International Nuclear Information System (INIS)

    Mitchel, R.E.J.; Jackson, J.S.

    1997-01-01

    Using a nose only inhalation system, 187 nine week old male Sprague-Dawley rats were exposed to two different concentrations of natural uranium ore dust aerosol (44% U) without significant radon content. Inhalation exposures averaged about 4.2 h/day, 5 days/week for 65 weeks at which point lung uranium burdens in the two groups averaged 0.9 and 1.9 mg/g dry weight. Animals (63) exposed to the air stream without dust served as controls. After inhalation exposure ceased, the rats were allowed to live for their natural lifetime, a maximum of about 900 days after the start of dust inhalation. Lung uranium burdens were measured at the time of death of each animal. Lung burdens were found to decline exponentially after dust inhalation ceased, and the rate of decline was independent of the initial lung burden. All lungs were examined at necropsy and histologically for lung tumors. Lung tumors of lung origin were observed in both exposed groups and in the control group. The frequency of primary malignant lung tumors was 0.016, 0.175 and 0.328 and primary non-malignant lung tumors 0.016, 0.135 and 0.131 in the control low and high aerosol exposed groups respectively. Absorbed dose to the lung was calculated for each animal in the study. The average maximum doses for all the animals exposed to the low or high concentration of dust aerosol were 0.87 Gy and 1.64 Gy respectively. The average risk of malignant lung tumors from inhaled natural uranium ore dust was therefore about 0.20 tumors/animal/Gy. For animals with lung tumors, the average doses were 0.98 and 1.90 in the exposed groups. In both exposed groups, the frequency of primary malignant or non-malignant lung tumors was significantly greater than in the control group (p < 0.02) and the frequency of primary malignant lung tumors in the two exposed group were significantly different from each other (p = 0.05). The frequency of primary lung tumors (malignant and non-malignant) was calculated as a function of dose

  17. Exubera. Inhale therapeutic systems.

    Science.gov (United States)

    Bindra, Sanjit; Cefalu, William T

    2002-05-01

    Inhale, in colaboration with Pfizer and Aventis Pharma (formerly Hoechst Marion Roussel; HMR), is developing an insulin formulation utilizing its pulmonary delivery technology for macromolecules for the potential treatment of type I and II diabetes. By July 2001, the phase III program had been completed and the companies had begun to assemble data for MAA and NDA filings; however, it was already clear at this time that additional data might be required for filing. By December 2001, it had been decided that the NDA should include an increased level of controlled, long-term pulmonary safety data in diabetic patients and a major study was planned to be completed in 2002, with the NDA filed thereafter (during 2002). US-05997848 was issued to Inhale Therapeutic Systems in December 1999, and corresponds to WO-09524183, filed in February 1995. Equivalent applications have appeared to date in Australia, Brazil, Canada, China, Czech Republic, Europe, Finland, Hungary, Japan, Norway, New Zealand, Poland and South Africa. This family of applications is specific to pulmonary delivery of insulin. In February 1999, Lehman Brothers gave this inhaled insulin a 60% probability of reaching market, with a possible launch date of 2001. The analysts estimated peak sales at $3 billion in 2011. In May 2000, Aventis predicted that estimated peak sales would be in excess of $1 billion. In February 2000, Merrill Lynch expected product launch in 2002 and predicted that it would be a multibillion-dollar product. Analysts Merril Lynch predicted, in September and November 2000, that the product would be launched by 2002, with sales in that year of e75 million, rising to euro 500 million in 2004. In April 2001, Merrill Lynch predicted that filing for this drug would occur in 2001. Following the report of the potential delay in regulatory filing, issued in July 2001, Deutsche Banc Alex Brown predicted a filing would take place in the fourth quarter of 2002 and launch would take place in the first

  18. Reversibility of pulmonary function after inhaling salbutamol in different doses and body postures in asthmatic children.

    Science.gov (United States)

    Visser, R; Kelderman, S; de Jongh, F H C; van der Palen, J; Thio, B J

    2015-10-01

    Pulmonary medication is often delivered in the form of medical aerosols designed for inhalation. Recently, breath actuated inhalers (BAI's) gained popularity as they can be used without spacers. A major drawback of BAI's is the impaction in the upper airway. Stretching the upper airway by a forward leaning body posture with the neck extended ("sniffing position") during inhalation may reduce upper airway impaction and improve pulmonary deposition. Aim of this study was to investigate the reversibility of lung function with different doses salbutamol inhaled with a BAI in the forward leaning posture compared to the standard posture in asthmatic children. 22 clinically stable asthmatic children, 5-14 years old, performed four reversibility measurements. Children inhaled 200 μg or 400 μg salbutamol with a BAI in the standard or in the forward leaning posture with the neck extended in a randomized single-blinded cross-over design. Reversibility of lung function after inhaling salbutamol in the forward leaning posture was not significantly different compared to inhalation in the standard posture. Mean FEV1 reversibility was significantly greater after inhaling 400 μg salbutamol compared to 200 μg salbutamol in the standard posture (9.4% ± 9.5% versus 4.5% ± 7.5%, difference 4.9% (95CI 0.9; 9.0%); p = 0.021). In clinically stable asthmatic children, inhalation of salbutamol with a BAI in a forward leaning posture does not increase reversibility of lung function. Inhalation of 400 μg compared to 200 μg salbutamol with a BAI does improve reversibility. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Physicochemical characterization of Capstone depleted uranium aerosols I: uranium concentration in aerosols as a function of time and particle size.

    Science.gov (United States)

    Parkhurst, Mary Ann; Cheng, Yung Sung; Kenoyer, Judson L; Traub, Richard J

    2009-03-01

    During the Capstone Depleted Uranium (DU) Aerosol Study, aerosols containing DU were produced inside unventilated armored vehicles (i.e., Abrams tanks and Bradley Fighting Vehicles) by perforation with large-caliber DU penetrators. These aerosols were collected and characterized, and the data were subsequently used to assess human health risks to personnel exposed to DU aerosols. The DU content of each aerosol sample was first quantified by radioanalytical methods, and selected samples, primarily those from the cyclone separator grit chambers, were analyzed radiochemically. Deposition occurred inside the vehicles as particles settled on interior surfaces. Settling rates of uranium from the aerosols were evaluated using filter cassette samples that collected aerosol as total mass over eight sequential time intervals. A moving filter was used to collect aerosol samples over time, particularly within the first minute after a shot. The results demonstrate that the peak uranium concentration in the aerosol occurred in the first 10 s after perforation, and the concentration decreased in the Abrams tank shots to about 50% within 1 min and to less than 2% after 30 min. The initial and maximum uranium concentrations were lower in the Bradley vehicle than those observed in the Abrams tank, and the concentration levels decreased more slowly. Uranium mass concentrations in the aerosols as a function of particle size were evaluated using samples collected in a cyclone sampler, which collected aerosol continuously for 2 h after perforation. The percentages of uranium mass in the cyclone separator stages ranged from 38 to 72% for the Abrams tank with conventional armor. In most cases, it varied with particle size, typically with less uranium associated with the smaller particle sizes. Neither the Abrams tank with DU armor nor the Bradley vehicle results were specifically correlated with particle size and can best be represented by their average uranium mass concentrations of 65

  20. PIXE application to the study of atmospheric aerosol

    International Nuclear Information System (INIS)

    Zhu Guanghua

    1998-11-01

    In order to confirm the measurement accuracy of PIXE (Particle Induced X-ray Emission), cross-check test were carried out between three laboratories. Thirty single element samples and one plural elements sample were used in the test. The agreements between three laboratories were evaluated to be better than 10% for the most of tested samples. The reproducibility test showed very good agreement and the dispersion in three times repeated PIXE measurements was within 6% on average. Using an automatic time sequence step sampler in Beijing collected atmospheric aerosol samples. Element concentrations were analyzed by PIXE technique. Then the data were analyzed by the absolute principal factor analysis (APFA) to evaluate the principal components and the percent variance explained by them. As a result, it shows that the PIXE analysis combed with statistical method can effectively resolve the aerosol components in urban area and distinguish between local and remote area aerosol components. The atmospheric aerosol samples were collected at four representative sites with an 8-stage cascade impactor sampler and analyzed for their elemental mass concentrations by PIXE analytic method. Based on some indicator elements, the characteristics of size distributions of particles from different sources were obtained

  1. Aerosol Activation Properties within and above Mixing Layer in the North China Plain

    Science.gov (United States)

    Deng, Z.; Ran, L.

    2013-12-01

    Aerosol particles, serving as cloud condensation nuclei (CCN), may modify the properties of clouds and have an impact on climate. The vertical distribution of aerosols and their activation properties is critical to quantify the effect of aerosols on clouds. An intensive field campaign, Vertical Observations of trace Gases and Aerosols in the North China Plain (VOGA-NCP 2013), was conducted in the North China Plain during the late July and early August 2013 to measure the vertical profiles of atmospheric components in this polluted region and estimate their effects on atmospheric environment and climate. Aerosols were measured with in-situ instruments and Lidar. Particularly, the aerosols were collected at 1000 m height with a 1 m3 bag sampler attached to a tethered balloon, and subsequently measured with combined scanning mobility particle sizer (SMPS) and CCN counter. Comparisons of size-resolved activation ratios at ground level and 1000 m height showed that aerosols in upper atmosphere were not only less concentrated, but also less CCN-active than those at the surface. The difference in aerosol properties between upper atmosphere and the ground indicates that the analysis of impacts of aerosols on cloud might be misleading in heavily polluted region based on the relationship of cloud properties and surface aerosols or column without considering the vertical distribution of aerosol activation abilities.

  2. The removal of inhaled 239Pu and 238Pu from beagle dogs by lung lavage and chelation treatment

    International Nuclear Information System (INIS)

    Muggenburg, B.A.; Mewhinney, J.A.; Miglio, J.J.; Slauson, D.O.; McClellan, R.O.

    1976-01-01

    Studies were conducted in beagle dogs to determine the efficiency of treatment by lung lavage and injections of chelating agents in removing inhaled plutonium of varied chemical forms and particle sizes. Polydisperse aerosols of 239 Pu were produced at different temperatures from 325 0 C to 1150 0 C to evaluate the effect of the chemical form of the particles. Aerosols of 238 Pu were produced at 1150 0 C only but were of different particle size or size distributions. Three dogs that inhaled each different plutonium aerosol were treated by lung lavages starting two days after the exposure. Subsequent lavages were performed on days 7, 10, 14, 21, 28, 35, 42, and 49 after exposure. Intravenous injections of 100 mg of diethylenetriaminepentaacetic acid (DTPA) as the calcium salt were given on days 1, 2, 3 and 4 after exposure and twice weekly thereafter to the time of sacrifice, 56 days after exposure. The 10 lung lavages removed from 18 to 49% of the initial lung burden of plutonium. The recovery of plutonium by lavage was similar irrespective of the temperature at which the aerosol was produced, however, lavage recovery decreased somewhat with increasing particle size. The efficacy of DTPA treatment increased with decreasing production temperature of the 239 Pu. Treatment with DTPA was not affected by particle size of the 0.8- and 1.9-μm monodisperse 239 Pu aerosol. The effectiveness of lung lavage decreased as the solubility of the aerosol particles increased whereas the effectiveness of the DTPA treatment increased as the solubility of the inhaled aerosol increased as shown by the lowest temperature aerosol and the aerosol-containing soluble fraction. These findings correlated qualitatively with a 2-hour in-vitro solubility test on the exposure aerosols. (author)

  3. Characterisation of aerosols produced by laser cutting

    International Nuclear Information System (INIS)

    Fauvel, S.; Pilot, G.; Dinechin, G. de; Gosse, X.; Arnaud, P.

    2007-01-01

    Powerful lasers represent a promising alternative solution to traditional cutting processes used in dismantling nuclear equipments. The use of optical fibers has an unquestionable advantage when dealing with airtight workshops. A study funded by COGEMA Marcoule was undertaken by IRSN/SERAC in collaboration with GIP/GERAILP in order to characterise the aerosols emitted by the cutting of evaporators elements with a 4 kW continuous wave Nd:YAG laser. For this study, laser cutting has been carried out in a tight room of 35 m 3 connected to a particle sampling pipe. Iso-kinetic samplers allowed the measurement of the aerosol concentration. A diffusional and inertial spectrometer (SDI 2001) - an Andersen impinger coupled to a diffusion battery - provided the size distribution. An electrostatic filter used upstream a HEPA filter, itself placed before the extractor fan, collected the majority of the emitted aerosol. Its efficiency was measured and controlled throughout the experiments. The results show the influence of the cutting conditions on the characteristics of the aerosol, and allow a comparison with other cutting tools. (authors)

  4. Modeling of Viral Aerosol Transmission and Detection

    KAUST Repository

    Khalid, Maryam; Amin, Osama; Ahmed, Sajid; Alouini, Mohamed-Slim

    2018-01-01

    The objective of this work is to investigate the spread mechanism of diseases in the atmosphere as an engineering problem. Among the viral transmission mechanisms that do not include physical contact, aerosol transmission is the most significant mode of transmission where virus-laden droplets are carried over long distances by wind. In this work, we focus on aerosol transmission of virus and introduce the idea of viewing virus transmission through aerosols and their transport as a molecular communication problem, where one has no control over transmission source but a robust receiver can be designed using nano-biosensors. To investigate this idea, a complete system is presented and end-toend mathematical model for the aerosol transmission channel is derived under certain constraints and boundary conditions. In addition to transmitter and channel, a receiver architecture composed of air sampler and Silicon Nanowire field effect transistor is also discussed. Furthermore, a detection problem is formulated for which maximum likelihood decision rule and the corresponding missed detection probability is discussed. At the end, simulation results are presented to investigate the parameters that affect the performance and justify the feasibility of proposed setup in related applications.

  5. The neighborhood MCMC sampler for learning Bayesian networks

    Science.gov (United States)

    Alyami, Salem A.; Azad, A. K. M.; Keith, Jonathan M.

    2016-07-01

    Getting stuck in local maxima is a problem that arises while learning Bayesian networks (BNs) structures. In this paper, we studied a recently proposed Markov chain Monte Carlo (MCMC) sampler, called the Neighbourhood sampler (NS), and examined how efficiently it can sample BNs when local maxima are present. We assume that a posterior distribution f(N,E|D) has been defined, where D represents data relevant to the inference, N and E are the sets of nodes and directed edges, respectively. We illustrate the new approach by sampling from such a distribution, and inferring BNs. The simulations conducted in this paper show that the new learning approach substantially avoids getting stuck in local modes of the distribution, and achieves a more rapid rate of convergence, compared to other common algorithms e.g. the MCMC Metropolis-Hastings sampler.

  6. Pulmonary lesions induced by inhaled plutonium in beagles

    International Nuclear Information System (INIS)

    Dagle, G.E.; Lund, J.E.; Park, J.F.

    1976-01-01

    The histopathologic features of pulmonary fibrosis and bronchiolo-alveolar carcinoma in beagles exposed to aerosols of 238 Pu or 239 Pu oxide are reviewed. A hypothesis of the pathogenesis of radiation pneumonitis induced by inhalation of plutonium oxide is presented; this hypothesis included phagocytosis of Pu particles, fibrosis responding to the necrosis, and alveolar cell hyperplasia compensating for alveolar cells killed by alpha radiation. Histopathologic features of the epithelial changes suggest a progression from hyperplasia to metaplasia and, finally, to bronchiolo-alveolar carcinoma. The possibility of concurrent radiation-induced lymphopenia contributing to the development of bronchiolo-alveolar carcinoma through a loss of immunologic surveillance is discussed

  7. Pulmonary lesions induced by inhaled plutonium in beagles

    International Nuclear Information System (INIS)

    Dagle, G.E.; Lund, J.E.; Park, J.F.

    1975-01-01

    The histopathologic features of pulmonary fibrosis and bronchiolo-alveolar carcinoma in beagles exposed to aerosols of plutonium oxide were reviewed. A hypothesis of the pathogenesis of radiation pneumonitis induced by inhalation of plutonium oxide was presented; this hypothesis included phagocytosis of plutonium particles, fibrosis responding to the necrosis, and alveolar cell hyperplasia compensating for alveolar cells killed by alpha radiation. Histopathologic features of the epithelial changes suggest a progression from hyperplasia to metaplasia and, finally, to bronchiolo-alveolar carcinoma. The possibility of concurrent radiation-induced lymphopenia contributing to the development of bronchiolo-alveolar carcinoma through a loss of immunologic surveillance was discussed

  8. The removal of inhaled 239Pu from beagle dogs by bronchopulmonary lavage and chelation therapy

    International Nuclear Information System (INIS)

    Muggenburg, B.A.; Mewhinney, J.A.; Slauson, D.O.; Miglio, J.J.; Ruoff, L.; Mersch, S.; McClellan, R.O.

    1976-01-01

    The efficacy of bronchopulmonary lavage and chelatan therapy for removing 239 Pu from beagle dogs after inhalation of 239 Pu aerosols having different solubilities has been investigated. The four aerosols used were nebulized from a solution of 239 PuCl 4 and heat treated at temperatures of 325, 600, 900 and 1150 0 C. Groups of six beagle dogs were exposed to each of the aerosols. Subsequently, three dogs in each group were treated by lavage and intravenous injections of DTPA. The remaining three dogs in each group served as untreated controls. It was found that bronchopulmonary lavage treatment was effective in removing nearly half of the 239 Pu activity from the lung regardless of the aerosol production temperature. This early removal of 239 Pu activity resulted in a significant reduction in daily dose rate and therefore cumulative α dose to lung. The effectiveness of DTPA treatment depended on aerosol production temperature, and was effective in reducing accumulation of 239 Pu in liver and skeleton of the dogs that inhaled aerosols produced at 325 0 and 600 0 C by enhancing urinary excretion of 239 Pu. (U.K.)

  9. Lung inhalation scintigraphy with radioactive aerosols in several pulmonary diseases

    International Nuclear Information System (INIS)

    Martins, L.R.; Marioni Filho, H.; Romaldini, H.; Uehara, C.; Alonso, G.

    1983-01-01

    The pulmonary ventilation scintigraphy with 99m Tc diethylene-triamine-pentaacetate (99mTc-DTPA) delivered through a new nebulizer system when analyzed together with the classic lung perfusion scintigraphy with 99mTc-labeled albumin macroaggregates (99mTcMAA) is a very important diagnostic tool in several pulmonary diseases. Several aspects of the lung ventilation-perfusion scintigraphy are studied in 15 people with no lung disease, smokers and nonsmokers. The findings with the lung ventilation-perfusion scintigraphy are also discussed in 34 patients with several pulmonary diseases: lung cancer, chronic obstructive lung disease, policystic pulmonary disease, and pulmonary embolims. The authors concluded that the procedure is a valuable diagnostic tool in several pulmonary diseases, especially because good lung images are obtained, no side effects were detected, the technique is ease and low cost, and it brings new informations, not available with other diagnostic methods. (author)

  10. Internal Dosimetry for Inhalation of Hafnium Tritide Aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Inkret, W.C.T.; Schillaci, M.E.; Boyce, M.K.; Cheng, Y.S.; Efurd, D.W.; Little, T.T.; Miller, G.; Musgrave, J.A.; Wermer, J.R

    2001-07-01

    Metal tritides with low dissolution rates may have residence times in the lungs which are considerably longer than the biological half-time normally associated with tritium in body water, resulting in long-term irradiation of the lungs by low energy {beta} particles and bremsstrahlung X rays. Samples of hafnium tritide were placed in a lung simulant fluid to determine approximate lung dissolution rates. Hafnium hydride samples were analysed for particle size distribution with a scanning electron microscope. Lung simulant data indicated a biological dissolution half-time for hafnium tritide on the order of 10{sup 5}d. Hafnium hydride particle sizes ranged between 2 and 10 {mu}m, corresponding to activity median aerodynamic diameters of 5 to 25 {mu}m. Review of in vitro dissolution data, development of a biokinetic model, and determination of secondary limits for 1 {mu}m AMAD particles are presented and discussed. (author)

  11. Dispersing the Mists: An Experimental History of Medicine Study into the Quality of Volatile Inhalations.

    Science.gov (United States)

    Murnane, Barry; Gallagher, Cathal T; Snell, Noel; Sanders, Mark; Moshksar, Ramin; Murnane, Darragh

    2017-06-01

    Dr. Nelson's Improved Inhaler was first marketed with an advertisement in The Lancet in 1865. Revolutionary at the time for its ease of use and patient-friendliness, the inhaler is still in use for self-treatment by many all over the world. On the occasion of its 150th anniversary, this study reports an experimental historical medicine approach to identify evidence for the quality of vapor inhalers. Through accessing reviews of the device's use by the contemporary medical establishment, it was established that Dr. Nelson's Inhaler enjoyed a reputation of quality and efficacy among reputable physicians generating empirical evidence of clinical performance. There was a general absence of product performance tests during this period. Therefore, modern inhalation performance testing was applied to test the aerosol delivery performance for Friars' Balsam, and its key chemical constituent, benzoic acid (BA). A respirable dose of 59.9 ± 9.0 μg of BA was aerosolized in a 10 minutes period from a dose of 3.3 mL Friars' Balsam (equivalent to 35.1 ± 0.2 mg of BA) in 375 mL of steaming water using the glass twin stage impinger at a flow rate of 60 L·min -1 . The respirable dose from a standardized aqueous BA inhalation formulation increased from 115.9 ± 10.6 to 200.2 ± 19.9 μg by increasing the simulated inhalation period from 5 to 10 minutes. When tested with a simulated inhalation maneuver (500 mL tidal volume, 13 minutes -1 respiration rate, 1:2 inspiratory:expiratory ratio) a respirable dose of 112.8 ± 40.3 μg was produced. This work has highlighted the potential for aerosol drug delivery using steam inhalers that are popular with patients. Physicians should therefore be aware of the potential for lung dosing with irritants when patients self-medicate using the Nelson Inhaler with vaporizing formulations such as Friars' Balsam.

  12. Lung delivery of aerosolized dextran.

    Science.gov (United States)

    Finlay, W H; Lange, C F; King, M; Speert, D P

    2000-01-01

    The ability of nebulizers to deliver dextran (nominal molecular mass, 4,000 g/mol) to the lung as an inhaled aerosol is evaluated by in vitro experimental methods and mathematical models. Dextran in isotonic saline was aerosolized by four nebulizer types (Pari LC STAR, Hudson T-Updraft II, Acorn II, and Sonix 2000) at dextran concentrations phase Doppler anemometry, filter collection, osmometry, and gravimetry. Mathematical models were used to estimate amounts of the characterized aerosols depositing in the different regions of lung models, and mathematical models of mucous thickness were then developed to estimate initial concentrations of the depositing dextran in the mucus of each conducting airway generation. Models of three subjects (4 yr old, 8 yr old, and adult) were used. The high viscosity of the dextran solutions tested (up to seven times that of water) negatively impacts nebulization, and results in poor performance with most delivery systems tested. Our results suggest that airway mucosal dextran concentrations associated with efficacy in previous animal and in vitro models are achievable with reasonable delivery times (

  13. A mathematics sampler topics for the liberal arts

    CERN Document Server

    Berlinghoff, William P; Skrien, Dale

    2001-01-01

    Now in its fifth edition, A Mathematics Sampler presents mathematics as both science and art, focusing on the historical role of mathematics in our culture. It uses selected topics from modern mathematics-including computers, perfect numbers, and four-dimensional geometry-to exemplify the distinctive features of mathematics as an intellectual endeavor, a problem-solving tool, and a way of thinking about the rapidly changing world in which we live. A Mathematics Sampler also includes unique LINK sections throughout the book, each of which connects mathematical concepts with areas of interest th

  14. Atmospheric fine and coarse mode aerosols at different environments of India and the Bay of Bengal during winter-2014: Implications of a coordinated campaign

    Digital Repository Service at National Institute of Oceanography (India)

    Sen, A.; Ahammed, Y.N.; Arya, B.C.; Banerjee, T.; Begam, R.G.; Baruah, B.P.; Chatterjee, A.; Choudhuri, A.K.; Dhir, A.; Das, T.; Dhyani, P.P.; Deb, N.C.; Gadi, R.; Gauns, M.; Ghosh, S.K.; Gupta, A.; Sharma, K.C.; Khan, A.H.; Kumari, K.M.; Kumar, M.; Kumar, A.; Kuniyal, J.C.; Lakhani, A.; Meena, R.K.; Mahapatra, P.S.; Naqvi, S.W.A.; Singh, D.P.; Pal, S.; Panda, S.; Rohtash; Saikia, J.; Saikia, P.; Sharma, A.; Sharma, P.; Saxena, M.; Shenoy, D.M.; Vachaspati, C.V.; Sharma, S.K.; Mandal, T.K.

    and 83–89�E longitudes. 2.2. Sample Collection and Analysis The APM 550, APM 460 NL and APM 430 samplers used during the campaign are manufactured by M/s. Envirotech Instruments Pvt. Ltd., New Delhi. The APM 550 is utilized for sampling aerosols falling... in the PM2.5 and PM10 size fractions (http://www.envirotechindia.com). The impactors are designed as per United States Environmental Protection Agency (USEPA) standards. Ambient air enters the sampler through an omni-directional air inlet. PM10 aerosols...

  15. Inhaled plutonium nitrate in dogs

    International Nuclear Information System (INIS)

    Dagle, G.E.; Cannon, W.C.; Ragan, H.A.; Watson, C.R.; Stevens, D.L.; Cross, F.T.; Dionne, P.J.; Harrington, T.P.

    1978-01-01

    Beagle dogs given a single inhalation exposure to 239 Pu(NO 3 ) 4 are being observed for life-span dose-effect relationships. Lymphopenia occurred at the two highest dosage levels as early as 1 mo following exposure and was associated with neutropenia and reduction in numbers of circulatory monocytes by 4 mo postexposure. Radiation pneumonitis developed in one dog at the highest dosage level at 14 mo postexposure. More rapid translocation to skeleton and liver occurred following inhalation of 238 Pu(NO 3 ) 4 than after 239 Pu(NO 3 ) 4 inhalation

  16. Evaluating the Relationship between Equilibrium Passive Sampler Uptake and Aquatic Organism Bioaccumulation,

    Science.gov (United States)

    Objectives. This review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) in water column and interstitial water exposures as a surrogate for organism bioaccumulation. Approach/Activities. Fifty-five studies were found where both passive sampler uptake...

  17. The influence of geometry and draught shields on the performance of passive samplers.

    Science.gov (United States)

    Hofschreuder, P; van der Meulen, W; Heeres, P; Slanina, S

    1999-04-01

    Passive samplers provide an excellent opportunity to perform indicative measurements or establish a dense network of measuring sites. A drawback compared with conventional active measuring methods is the larger spread of results. This variation can, to a large extent, be attributed to the influence of temperature, sampler geometry and wind on sampling results. A proper design of sampler geometry and optimum choice of draught shield can reduce the influence of wind velocity on a badge type sampler to less than 10%. Wire mesh screens prove to be inadequate in damping turbulence. Filters give good results. Attention should be paid to the size and isolation value of the walls of the sampler to prevent thermal updrafts occurring within the sampler. Tube type samplers are less influenced by wind, provided that turbulence is prevented from influencing diffusion within the sampler.

  18. Reuter Centrifugal Air Sampler: Measurement of Effective Airflow Rate and Collection Efficiency

    OpenAIRE

    Macher, J. M.; First, M. W.

    1983-01-01

    Incorrect calculation of effective air sampling rate and disregard of differences in collection efficiency among samplers can lead to false conclusions about the usefulness of samplers for measuring concentrations of airborne microorganisms.

  19. Particle size of radioactive aerosols generated during machine operation in high-energy proton accelerators

    International Nuclear Information System (INIS)

    Oki, Yuichi; Kanda, Yukio; Kondo, Kenjiro; Endo, Akira

    2000-01-01

    In high-energy accelerators, non-radioactive aerosols are abundantly generated due to high radiation doses during machine operation. Under such a condition, radioactive atoms, which are produced through various nuclear reactions in the air of accelerator tunnels, form radioactive aerosols. These aerosols might be inhaled by workers who enter the tunnel just after the beam stop. Their particle size is very important information for estimation of internal exposure doses. In this work, focusing on typical radionuclides such as 7 Be and 24 Na, their particle size distributions are studied. An aluminum chamber was placed in the EP2 beam line of the 12-GeV proton synchrotron at High Energy Accelerator Research Organization (KEK). Aerosol-free air was introduced to the chamber, and aerosols formed in the chamber were sampled during machine operation. A screen-type diffusion battery was employed in the aerosol-size analysis. Assuming that the aerosols have log-normal size distributions, their size distributions were obtained from the radioactivity concentrations at the entrance and exit of the diffusion battery. Radioactivity of the aerosols was measured with Ge detector system, and concentrations of non-radioactive aerosols were obtained using condensation particle counter (CPC). The aerosol size (radius) for 7 Be and 24 Na was found to be 0.01-0.04 μm, and was always larger than that for non-radioactive aerosols. The concentration of non-radioactive aerosols was found to be 10 6 - 10 7 particles/cm 3 . The size for radioactive aerosols was much smaller than ordinary atmospheric aerosols. Internal doses due to inhalation of the radioactive aerosols were estimated, based on the respiratory tract model of ICRP Pub. 66. (author)

  20. Sidestream smoke inhalation decreases respiratory clearance of 99mTc-DTPA acutely

    International Nuclear Information System (INIS)

    Yates, D.H.; Havill, K.; Thompson, M.M.; Rittano, A.B.; Chu, J.; Glanville, A.R.

    1996-01-01

    The permeability of the alveolar-capillary barrier to an inhaled aerosol of technetium 99m labelled diethylenetriamine penta-acetate ( 99m Tc-DTPA is used as an index of alveolar epithelial injury. Permeability is greatly increased in active smokers. The aim of this study was to determine the effect of sidestream smoke inhalation on permeability as this has not been described previously. Lung clearance of inhaled 99m Tc-DTPA aerosol was measured in 20 normal non-smoking subjects before and after exposure to one hours sidestream smoke inhalation. Measured carbon monoxide (CO) levels rose to a maximum of 23.5 ±6.2 ppm from baseline values of 0.6±1.3 (p 99m Tc-DTPA clearance rose from baseline 69.1± 15.6 (mean ± to 77.4 ±17.8) after smoke exposure. No effect of 99m Tc-DTPA scanning of sidestream smoke was demonstrated on lung function. It was concluded that low level sidestream smoke inhalation decreases 99m Tc-DTPA clearance acutely in humans. The mechanism of this unexpected result is not established but may include differences in constituents between sidestream and mainstream smoke, alterations in pulmonary microvascular blood flow, or changes in surfactant due to an acute phase irritant response. 34 refs., 2 figs

  1. Inhalation of uranium nanoparticles: respiratory tract deposition and translocation to secondary target organs in rats.

    Science.gov (United States)

    Petitot, Fabrice; Lestaevel, Philippe; Tourlonias, Elie; Mazzucco, Charline; Jacquinot, Sébastien; Dhieux, Bernadette; Delissen, Olivia; Tournier, Benjamin B; Gensdarmes, François; Beaunier, Patricia; Dublineau, Isabelle

    2013-03-13

    Uranium nanoparticles (fuel cycle and during remediation and decommissioning of nuclear facilities. Explosions and fires in nuclear reactors and the use of ammunition containing depleted uranium can also produce such aerosols. The risk of accidental inhalation of uranium nanoparticles by nuclear workers, military personnel or civilian populations must therefore be taken into account. In order to address this issue, the absorption rate of inhaled uranium nanoparticles needs to be characterised experimentally. For this purpose, rats were exposed to an aerosol containing 10⁷ particles of uranium per cm³ (CMD=38 nm) for 1h in a nose-only inhalation exposure system. Uranium concentrations deposited in the respiratory tract, blood, brain, skeleton and kidneys were determined by ICP-MS. Twenty-seven percent of the inhaled mass of uranium nanoparticles was deposited in the respiratory tract. One-fifth of UO₂ nanoparticles were rapidly cleared from lung (T(½)=2.4 h) and translocated to extrathoracic organs. However, the majority of the particles were cleared slowly (T(½)=141.5 d). Future long-term experimental studies concerning uranium nanoparticles should focus on the potential lung toxicity of the large fraction of particles cleared slowly from the respiratory tract after inhalation exposure. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. Optimizing the Entrainment Geometry of a Dry Powder Inhaler: Methodology and Preliminary Results.

    Science.gov (United States)

    Kopsch, Thomas; Murnane, Darragh; Symons, Digby

    2016-11-01

    For passive dry powder inhalers (DPIs) entrainment and emission of the aerosolized drug dose depends strongly on device geometry and the patient's inhalation manoeuvre. We propose a computational method for optimizing the entrainment part of a DPI. The approach assumes that the pulmonary delivery location of aerosol can be determined by the timing of dose emission into the tidal airstream. An optimization algorithm was used to iteratively perform computational fluid dynamic (CFD) simulations of the drug emission of a DPI. The algorithm seeks to improve performance by changing the device geometry. Objectives were to achieve drug emission that was: A) independent of inhalation manoeuvre; B) similar to a target profile. The simulations used complete inhalation flow-rate profiles generated dependent on the device resistance. The CFD solver was OpenFOAM with drug/air flow simulated by the Eulerian-Eulerian method. To demonstrate the method, a 2D geometry was optimized for inhalation independence (comparing two breath profiles) and an early-bolus delivery. Entrainment was both shear-driven and gas-assisted. Optimization for a delay in the bolus delivery was not possible with the chosen geometry. Computational optimization of a DPI geometry for most similar drug delivery has been accomplished for an example entrainment geometry.

  3. The toxicity of inhaled particles of 238PuO2 in dogs

    International Nuclear Information System (INIS)

    Muggenburg, B.A.; Guilmette, R.A.; Griffith, W.C. Jr.; Hahn, F.F.; Boecker, B.B.

    1991-01-01

    This study was conducted to determine the toxicity of inhaled 238 PuO 2 in the dog. Inhalation was selected because it is the mostly likely route of human exposure in the event of an accidental airborne release. Of 166 dog in the study, 72 inhaled 1.5μm and 72 inhaled 3.0 μm activity median aerodynamic diameter particles of 238 PuO 2 . Another 24 dogs inhaled the aerosol vector without plutonium. The aerosol exposures resulted in initial pulmonary burdens ranging from 37 to 0.11 and 55.5 to 0.37 kBq of 238 Pu/kg body mass, of 1.5 μm and 3.0 μ, particles, respectively. The particles dissolved slowly resulting in translocation of the Pu to liver, bone and other sites. The dogs were observed for biological effects over their life span. Necropsies were performed at death, and tissues were examined microscopically. The principal late-occurring effects were tumors of the lung, skeleton, and liver. Risk factors estimated for these cancers were 2800 lung cancers/10 4 Gy, 800 liver cancers/10 4 Gy, and 6200 bone cancers/10 4 Gy for dogs. The potential hazard from 238 Pu to humans may include tumors of the lung, bone and liver because of the likelihood of similarity of the dose patterns for the two species. 10 refs., 1 fig., 3 tabs

  4. Nanomaterial inhalation exposure from nanotechnology-based cosmetic powders: a quantitative assessment

    International Nuclear Information System (INIS)

    Nazarenko, Yevgen; Zhen Huajun; Han Taewon; Lioy, Paul J.; Mainelis, Gediminas

    2012-01-01

    In this study we quantified exposures to airborne particles ranging from 14 nm to 20 μm due to the use of nanotechnology-based cosmetic powders. Three nanotechnology-based and three regular cosmetic powders were realistically applied to a mannequin’s face while measuring the concentration and size distribution of inhaled aerosol particles. Using these data we calculated that the highest inhaled particle mass was in the coarse aerosol fraction (2.5–10 μm), while particles <100 nm made minimal contribution to the inhaled particle mass. For all powders, 85–93 % of aerosol deposition occurred in the head airways, while <10 % deposited in the alveolar and <5 % in the tracheobronchial regions. Electron microscopy data suggest that nanomaterials were likely distributed as agglomerates across the entire investigated aerosol size range (14 nm–20 μm). Thus, investigation of nanoparticle health effects should consider not only the alveolar region, but also other respiratory system regions where substantial nanomaterial deposition during the actual nanotechnology-based product use would occur.

  5. Enhanced surface sampler and process for collection and release of analytes

    Energy Technology Data Exchange (ETDEWEB)

    Addleman, Raymond S; Atkinson, David A; Bays, John T; Chouyyok, Wilaiwan; Cinson, Anthony D; Ewing, Robert G; Gerasimenko, Aleksandr A

    2015-02-03

    An enhanced swipe sampler and method of making are described. The swipe sampler is made of a fabric containing selected glass, metal oxide, and/or oxide-coated glass or metal fibers. Fibers are modified with silane ligands that are directly attached to the surface of the fibers to functionalize the sampling surface of the fabric. The swipe sampler collects various target analytes including explosives and other threat agents on the surface of the sampler.

  6. Development of a personal multi-pollutant exposure sampler for particulate matter and criteria gases

    Energy Technology Data Exchange (ETDEWEB)

    Chang, I.T.; Sarnat, J.; Wolfson, J.M.; Rojas-Bracho, L.; Suh, H.H.; Koutrakis, P. [Harvard Univ., Boston, MA (United States). School of Public Health

    1999-12-01

    A novel personal sampler is reported which allows simultaneous measurement of PM{sub 2,5}, and PM{sub 10}, ozone, nitrogen dioxide, and sulfur dioxide. This method combines previously used samplers for personal mass measurement with passive samplers for criteria gases and uses a single pump. Preliminarily results are reported for laboratory chamber tests and field comparisons with reference methods for both mass and criteria gases. These results demonstrate the suitability of this sampler of exposure assessment studies. (authors)

  7. Validating CFD Predictions of Pharmaceutical Aerosol Deposition with In Vivo Data.

    Science.gov (United States)

    Tian, Geng; Hindle, Michael; Lee, Sau; Longest, P Worth

    2015-10-01

    CFD provides a powerful approach to evaluate the deposition of pharmaceutical aerosols; however, previous studies have not compared CFD results of deposition throughout the lungs with in vivo data. The in vivo datasets selected for comparison with CFD predictions included fast and slow clearance of monodisperse aerosols as well as 2D gamma scintigraphy measurements for a dry powder inhaler (DPI) and softmist inhaler (SMI). The CFD model included the inhaler, a characteristic model of the mouth-throat (MT) and upper tracheobronchial (TB) airways, stochastic individual pathways (SIPs) representing the remaining TB region, and recent CFD-based correlations to predict pharmaceutical aerosol deposition in the alveolar airways. For the monodisperse aerosol, CFD predictions of total lung deposition agreed with in vivo data providing a percent relative error of 6% averaged across aerosol sizes of 1-7 μm. With the DPI and SMI, deposition was evaluated in the MT, central airways (bifurcations B1-B7), and intermediate plus peripheral airways (B8 through alveoli). Across these regions, CFD predictions produced an average relative error <10% for each inhaler. CFD simulations with the SIP modeling approach were shown to accurately predict regional deposition throughout the lungs for multiple aerosol types and different in vivo assessment methods.

  8. Inhaled Corticosteroids (ICSs) and Pregnancy

    Science.gov (United States)

    ... of the airways in the lungs and reduce mucus production so that asthma attacks are less likely. ... of medicine that would be in the breast milk following inhalation is likely too small to cause ...

  9. Recreational atmospheric pollution episodes: Inhalable metalliferous particles from firework displays

    Science.gov (United States)

    Moreno, Teresa; Querol, Xavier; Alastuey, Andrés; Cruz Minguillón, Mari; Pey, Jorge; Rodriguez, Sergio; Vicente Miró, José; Felis, Carles; Gibbons, Wes

    The use of fireworks creates an unusual and distinctive anthropogenic atmospheric pollution event. We report on aerosol samples collected during Las Fallas in Valencia, a 6-day celebration famous for its firework displays, and add comparative data on firework- and bonfire-contaminated atmospheric aerosol samples collected from elsewhere in Spain (Barcelona, L'Alcora, and Borriana) and during the Guy Fawkes celebrations in London. Specific high-profile official firework events during Las Fallas included the afternoon Mascletà and the nightly aerial displays (especially in the climactic final 2 days of the fiesta) and were accompanied by pollution spikes in suspended particles, NO, SO 2, and the creation and dispersal of an aerosol cloud enriched in a range of metallic elements. Notable metal aerosol concentration increases recorded during Las Fallas were potassium (from 500 to 5900 ng m -3), aluminium (as Al 2O 3 from around 600 to 2200 ng m -3), titanium (from 200 to 700 ng m -3), magnesium (from 100 to 500 ng m -3), lead (from 17 to 379 ng m -3), barium (from 39 to 322 ng m -3), strontium (from 3 to 112 ng m -3), copper (from 12 to 71 ng m -3), and antimony (from 1 to 52 ng m -3). Firework-contaminated aerosols of similarly metalliferous composition were also identified at the other monitoring sites, although different sites show variations attributable to other sources such as bonfires and local industry. Unusual levels of the trace elements Ba, Sr and (to a lesser extent) Cu, always in proportions with Ba dominant, along with strongly enhanced K, Pb, and Sb, are identified as being particularly characteristic of firework aerosols. Although firework-related recreational pollution episodes are transient in nature, they are highly concentrated, contribute significantly to total annual metal emissions, and are on average fine enough to be easily inhaled and a health risk to susceptible individuals.

  10. 30 CFR 74.5 - Tests of coal mine dust personal sampler units.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of coal mine dust personal sampler units... Personal Sampler Unit § 74.5 Tests of coal mine dust personal sampler units. (a) The National Institute for... tests and evaluations to determine whether the pump unit of a CMDPSU that is submitted for approval...

  11. 50 CFR 697.12 - At-sea sea sampler/observer coverage.

    Science.gov (United States)

    2010-10-01

    ... sampler/observer access to and use of the vessel's communications equipment and personnel upon request for...) Allow the sea sampler/observer to inspect and copy the vessel's log, communications log, and records... must: (1) Notify the sea sampler/observer of any sea turtles, marine mammals, or other specimens taken...

  12. Radioaerosol Inhalation Lung Scan in Pulmonary Emphysema

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Jeong Soo; Park, Yong Ha; Kyo, Chung Soo; Bahk, Yong Whee [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1990-07-15

    Perfusion and ventilation imagings of the lung are well established procedure for diagnosing pulmonary embolism, differentiation it from chronic obstructive lung disease, and making an early detection of chronic obstructive lung disease. To evaluate the usefulness of radioaerosol inhalation imaging (RII) in chronic obstructive lung disease, especially pulmonary emphysema, we analyzed RIIs of five normal adult non-smokers, five asymptomatic smokers (age 25-42 years with the mean 36), and 21 patients with pulmonary emphysema (age 59-78 years with the mean 67). Scintigrams were obtained with radioaerosol produced by a BARC nebuliser with 15 mCi of {sup 99m}Tc-phytate. Scanning was performed in the anterior, posterior, and lateral projections after five to 10-minute inhalation of the radioaerosol on sitting position. The scans were analyzed and correlated with the results of pulmonary function studies and chest radiographs. Also lung perfusion scan with {sup 99m}Tc-MAA was performed in 12 patients. In five patients, we performed follow-up scans for the evaluation of the effects of a bronchodilator. Based on the X-ray findings and clinical symptoms, pulmonary emphysema was classified into four types: centrilobular (3 patients), panlobular (4 patients), intermediate (10 patients), and combined (4 patients). RII findings were patternized according to the type, extent, and intensity of the aerosol deposition in the central bronchial and bronchopulmonary system and lung parenchyma. 10 controls, normal five non-smokers and three asymptomatic smokers revealed homogeneous parenchymal deposition in the entire lung fields without central bronchial deposition. The remaining two of asymptomatic smokers revealed mild central airway deposition. The great majority of the patients showed either central (9/21) or combined type (10/21) of bronchopulmonary deposition and the remaining two patients peripheral bronchopulmonary deposition. Parenchymal aerosol deposition in pulmonary

  13. Radioaerosol Inhalation Lung Scan in Pulmonary Emphysema

    International Nuclear Information System (INIS)

    Jeon, Jeong Soo; Park, Yong Ha; Chung Soo Kyo; Bahk, Yong Whee

    1990-01-01

    Perfusion and ventilation imagings of the lung are well established procedure for diagnosing pulmonary embolism, differentiation it from chronic obstructive lung disease, and making an early detection of chronic obstructive lung disease. To evaluate the usefulness of radioaerosol inhalation imaging (RII) in chronic obstructive lung disease, especially pulmonary emphysema, we analyzed RIIs of five normal adult non-smokers, five asymptomatic smokers (age 25-42 years with the mean 36), and 21 patients with pulmonary emphysema (age 59-78 years with the mean 67). Scintigrams were obtained with radioaerosol produced by a BARC nebuliser with 15 mCi of 99m Tc-phytate. Scanning was performed in the anterior, posterior, and lateral projections after five to 10-minute inhalation of the radioaerosol on sitting position. The scans were analyzed and correlated with the results of pulmonary function studies and chest radiographs. Also lung perfusion scan with 99m Tc-MAA was performed in 12 patients. In five patients, we performed follow-up scans for the evaluation of the effects of a bronchodilator. Based on the X-ray findings and clinical symptoms, pulmonary emphysema was classified into four types: centrilobular (3 patients), panlobular (4 patients), intermediate (10 patients), and combined (4 patients). RII findings were patternized according to the type, extent, and intensity of the aerosol deposition in the central bronchial and bronchopulmonary system and lung parenchyma. 10 controls, normal five non-smokers and three asymptomatic smokers revealed homogeneous parenchymal deposition in the entire lung fields without central bronchial deposition. The remaining two of asymptomatic smokers revealed mild central airway deposition. The great majority of the patients showed either central (9/21) or combined type (10/21) of bronchopulmonary deposition and the remaining two patients peripheral bronchopulmonary deposition. Parenchymal aerosol deposition in pulmonary emphysema was

  14. Inhaled plutonium oxide in dogs

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This project is concerned with long-term experiments to determine the life-span dose-effect relationships of inhaled 239 PuO 2 and 238 PuO 2 in beagles. The data will be used to estimate the health effects of inhaled transuranics. The tissue distribution of plutonium, radiation effects in the lung and hematologic changes in plutonium-exposed beagles with lung tumors were evaluated

  15. Respirable versus inhalable dust sampling

    International Nuclear Information System (INIS)

    Hondros, J.

    1987-01-01

    The ICRP uses a total inhalable dust figure as the basis of calculations on employee lung dose. This paper was written to look at one aspect of the Olympic Dam dust situation, namely, the inhalable versus respirable fraction of the dust cloud. The results of this study will determine whether it is possible to use respirable dust figures, as obtained during routine monitoring to help in the calculations of employee exposure to internal radioactive contaminants

  16. Aerosol filtration

    International Nuclear Information System (INIS)

    Klein, M.; Goossens, W.R.A.; De Smet, M.; Trine, J.; Hertschap, M.

    1984-01-01

    This report summarizes the work on the development of fibre metallic prefilters to be placed upstream of HEPA filters for the exhaust gases of nuclear process plants. Investigations at ambient and high temperature were carried out. Measurements of the filtration performance of Bekipor porous webs and sintered mats were performed in the AFLT (aerosol filtration at low temperature) unit with a throughput of 15 m 3 /h. A parametric study on the influence of particle size, fibre diameter, number of layers and superficial velocity led to the optimum choice of the working parameters. Three selected filter types were then tested with polydisperse aerosols using a candle-type filter configuration or a flat-type filter configuration. The small-diameter candle type is not well suited for a spraying nozzles regeneration system so that only the flat-type filter was retained for high-temperature tests. A high-temperature test unit (AFHT) with a throughput of 8 to 10 m 3 /h at 400 0 C was used to test the three filter types with an aerosol generated by high-temperature calcination of a simulated nitric acid waste solution traced with 134 Cs. The regeneration of the filter by spray washing and the effect of the regeneration on the filter performance was studied for the three filter types. The porous mats have a higher dust loading capacity than the sintered web which means that their regeneration frequency can be kept lower

  17. Estimation of inhaled airborne particle number concentration by subway users in Seoul, Korea

    International Nuclear Information System (INIS)

    Kim, Minhae; Park, Sechan; Namgung, Hyeong-Gyu; Kwon, Soon-Bark

    2017-01-01

    Exposure to airborne particulate matter (PM) causes several diseases in the human body. The smaller particles, which have relatively large surface areas, are actually more harmful to the human body since they can penetrate deeper parts of the lungs or become secondary pollutants by bonding with other atmospheric pollutants, such as nitrogen oxides. The purpose of this study is to present the number of PM inhaled by subway users as a possible reference material for any analysis of the hazards to the human body arising from the inhalation of such PM. Two transfer stations in Seoul, Korea, which have the greatest number of users, were selected for this study. For 0.3–0.422 μm PM, particle number concentration (PNC) was highest outdoors but decreased as the tester moved deeper underground. On the other hand, the PNC between 1 and 10 μm increased as the tester moved deeper underground and showed a high number concentration inside the subway train as well. An analysis of the particles to which subway users are actually exposed to (inhaled particle number), using particle concentration at each measurement location, the average inhalation rate of an adult, and the average stay time at each location, all showed that particles sized 0.01–0.422 μm are mostly inhaled from the outdoor air whereas particles sized 1–10 μm are inhaled as the passengers move deeper underground. Based on these findings, we expect that the inhaled particle number of subway users can be used as reference data for an evaluation of the hazards to health caused by PM inhalation. - Highlights: • Size-dependent aerosol number was measured along the path of subway user. • Particles less than 0.4 μm were inhaled in outdoor but less so as deeper underground. • Coarse particles were inhaled significantly as users moved deeper underground. - We estimated the inhaled aerosol number concentration depending on particle size along the path of subway users.

  18. Performance of multiple HEPA filters against plutonium aerosols

    International Nuclear Information System (INIS)

    Gonzales, M.; Elder, J.; Ettinger, H.

    1975-01-01

    Performance of multiple stages of High Efficiency Particulate Air (HEPA) filters against aerosols similar to those produced by plutonium processing facilities has been verified as part of an experimental program. A system of three HEPA filters in series was tested against 238 PuO 2 aerosol concentrations as high as 3.3 x 10 10 d/s-m 3 . An air nebulization aerosol generation system, using ball milled plutonium oxide suspended in water, provided test aerosols with size characteristics similar to those defined by a field sampling program at several different AEC plutonium processing facilities. Aerosols have been produced ranging from 0.22 μm activity median aerodynamic diameter (amad) to 1.6 μm amad. The smaller size distributions yield 10 to 30 percent of the total activity in the less than 0.22 μm size range allowing efficiency measurement as a function of size for the first two HEPA filters in series. The low level of activity on the sampler downstream of the third HEPA filter (approximately 0.01 c/s) precludes aerosol size characterization downstream of this filter. For the first two HEPA filters, overall efficiency, and efficiency as a function of size, exceeds 99.98 percent including the <0.12 μm and the 0.12 to 0.22 μm size intervals. Efficiency of the third HEPA filter is somewhat lower with an overall average efficiency of 99.8 percent and an apparent minimum efficiency of 99.5 percent. This apparently lower efficiency is an artifact due to the low level of activity on the sampler downstream of HEPA No. 3 and the variations due to counting statistics. Recent runs with higher concentrations, thereby improving statistical variations, show efficiencies well within minimum requirements. (U.S.)

  19. Radon and aerosol release from open-pit uranium mining

    International Nuclear Information System (INIS)

    Thomas, V.W.; Nielson, K.K.; Mauch, M.L.

    1982-08-01

    The quantity of 222 Rn (hereafter called radon) released per unit of uranium produced from open pit mining has been determined. A secondary objective was to determine the nature and quantity of airborne particles resulting from mine operations. To accomplish these objectives, a comprehensive study of the release rates of radon and aerosol material to the atmosphere was made over a one-year period from April 1979 to May 1980 at the Morton Ranch Mine which was operated by United Nuclear Corporation (UNC) in partnership with Tennessee Valley Authority (TVA). The mine is now operated for TVA by Silver King Mines. Morton Ranch Mine was one of five open pit uranium mines studied in central Wyoming. Corroborative measurements were made of radon flux and 226 Ra (hereafter called radium) concentrations of various surfaces at three of the other mines in October 1980 and again at these three mines plus a fourth in April of 1981. Three of these mines are located in the Powder River Basin, about 80 kilometers east by northeast of Casper. One is located in the Shirley Basin, about 60 km south of Casper, and the remaining one is located in the Gas Hills, approximately 100 km west of Casper. The one-year intensive study included simultaneous measurement of several parameters: continuous measurement of atmospheric radon concentration near the ground at three locations, monthly 24-hour radon flux measurements from various surfaces, radium analyses of soil samples collected under each of the flux monitoring devices, monthly integrations of aerosols on dichotomous aerosol samplers, analysis of aerosol samplers for total dust loading, aerosol elemental and radiochemical composition, aerosol elemental composition by particle size, wind speed, wind direction, temperature, barometric pressure, and rainfall

  20. TOMS Absorbing Aerosol Index

    Data.gov (United States)

    Washington University St Louis — TOMS_AI_G is an aerosol related dataset derived from the Total Ozone Monitoring Satellite (TOMS) Sensor. The TOMS aerosol index arises from absorbing aerosols such...

  1. Developments in Emission Measurements Using Lightweight Sensors and Samplers.

    Science.gov (United States)

    Lightweight emission measurement systems making use of miniaturized sensors and samplers have been developed for portable and aerial sampling for an array of pollutants. Shoebox-sized systems called “Kolibri”, weighing 3-5 kg, have been deployed on NASA-flown unmanned...

  2. Operability test procedure for 211BA flow proportional sampler

    International Nuclear Information System (INIS)

    Weissenfels, R.D.

    1994-01-01

    The purpose of this operability test procedure (OTP) is to verify the 211-BA flow proportional sampler system and components function correctly as intended by design. System test will include the sampling system, all associated instrumentation, and Facility Process Monitor and Control System (FPMCS). The combined chemical sewer stream from B Plant flows through sump 211BA-SMP-01 located in 211-BA and is continuously monitored for gamma and beta radiation and pH. 211-BA has been upgraded to include a flow proportional sampler. A specified sample volume will be withdrawn at programmed intervals from the 211BA sump and deposited in a 19 liter plastic carboy. The sampler will be programmed per the vendor installation and operations manual by B Plant instrument maintenance personnel. Samples will be taken during five consecutive sample cycles with the sample volumes and sample frequencies recorded for comparison purposes. Additional tests related to the sampler include the alarm circuitry for loss of power and failure to obtain sample

  3. Fluidic Sampler. Tanks Focus Area. OST Reference No. 2007

    International Nuclear Information System (INIS)

    1999-01-01

    Problem Definition; Millions of gallons of radioactive and hazardous wastes are stored in underground tanks across the U.S. Department of Energy (DOE) complex. To manage this waste, tank operators need safe, cost-effective methods for mixing tank material, transferring tank waste between tanks, and collecting samples. Samples must be collected at different depths within storage tanks containing various kinds of waste including salt, sludge, and supernatant. With current or baseline methods, a grab sampler or a core sampler is inserted into the tank, waste is maneuvered into the sample chamber, and the sample is withdrawn from the tank. The mixing pumps in the tank, which are required to keep the contents homogeneous, must be shut down before and during sampling to prevent airborne releases. These methods are expensive, require substantial hands-on labor, increase the risk of worker exposure to radiation, and often produce nonrepresentative and unreproducible samples. How It Works: The Fluidic Sampler manufactured by AEA Technology Engineering Services, Inc., enables tank sampling to be done remotely with the mixing pumps in operation. Remote operation minimizes the risk of exposure to personnel and the possibility of spills, reducing associated costs. Sampling while the tank contents are being agitated yields consistently homogeneous, representative samples and facilitates more efficient feed preparation and evaluation of the tank contents. The above-tank portion of the Fluidic Sampler and the replacement plug and pipework that insert through the tank top are shown.

  4. Observation of 45 GHz current waveforms using HTS sampler

    International Nuclear Information System (INIS)

    Maruyama, M.; Suzuki, H.; Hato, T.; Wakana, H.; Nakayama, K.; Ishimaru, Y.; Horibe, O.; Adachi, S.; Kamitani, A.; Suzuki, K.; Oshikubo, Y.; Tarutani, Y.; Tanabe, K.

    2005-01-01

    We succeeded in observing high-frequency current waveforms up to 45 GHz using a high-temperature superconducting (HTS) sampler. In this experiment, we used a sampler circuit with a superconducting pickup coil, which magnetically detects current signals flowing through a micro-strip line on a printed board placed outside the cryochamber. This type of measurement enables non-contact current-waveform observation that seems useful for analyses of EMI, defects in LSI, etc. Computer simulation reveals that one of our latest versions of HTS sampler circuits having Josephson transmission lines with optimized biases as buffers has a potential of sampling high-frequency signals with a bandwidth above 100 GHz. To realize the circuit parameters required in the simulations, we developed an HTS circuit fabrication process employing a lower ground plane structure with SrSnO 3 insulating layers. We consider that improvement of the circuit fabrication process and optimization of the pickup coil lead to much higher signal frequency observable by the sampler

  5. Modeling the Fate of Expiratory Aerosols and the Associated Infection Risk in an Aircraft Cabin Environment

    DEFF Research Database (Denmark)

    Wan, M.P.; To, G.N.S.; Chao, C.Y.H.

    2009-01-01

    to estimate the risk of infection by contact. The environmental control system (ECS) in a cabin creates air circulation mainly in the lateral direction, making lateral dispersions of aerosols much faster than longitudinal dispersions. Aerosols with initial sizes under 28 m in diameter can stay airborne......The transport and deposition of polydispersed expiratory aerosols in an aircraft cabin were simulated using a Lagrangian-based model validated by experiments conducted in an aircraft cabin mockup. Infection risk by inhalation was estimated using the aerosol dispersion data and a model was developed...

  6. Inhalational Gentamicin Treatment Is Effective Against Pneumonic Plague in a Mouse Model

    Directory of Open Access Journals (Sweden)

    David Gur

    2018-04-01

    Full Text Available Pneumonic plague is an infectious disease characterized by rapid and fulminant development of acute pneumonia and septicemia that results in death within days of exposure. The causative agent of pneumonic plague, Yersinia pestis (Y. pestis, is a Tier-1 bio-threat agent. Parenteral antibiotic treatment is effective when given within a narrow therapeutic window after symptom onset. However, the non-specific “flu-like” symptoms often lead to delayed diagnosis and therapy. In this study, we evaluated inhalational gentamicin therapy in an infected mouse model as a means to improve antibiotic treatment efficacy. Inhalation is an attractive route for treating lung infections. The advantages include directly dosing the main infection site, the relative accessibility for administration and the lack of extensive enzymatic drug degradation machinery. In this study, we show that inhalational gentamicin treatment administered 24 h post-infection, prior to the appearance of symptoms, protected against lethal intranasal challenge with the fully virulent Y. pestis Kimberley53 strain (Kim53. Similarly, a high survival rate was demonstrated in mice treated by inhalation with another aminoglycoside, tobramycin, for which an FDA-approved inhaled formulation is clinically available for cystic fibrosis patients. Inhalational treatment with gentamicin 48 h post-infection (to symptomatic mice was also successful against a Y. pestis challenge dose of 10 i.n.LD50. Whole-body imaging using IVIS technology demonstrated that adding inhalational gentamicin to parenteral therapy accelerated the clearance of Y. pestis from the lungs of infected animals. This may reduce disease severity and the risk of secondary infections. In conclusion, our data suggest that inhalational therapy with aerosolized gentamicin may be an effective prophylactic treatment against pneumonic plague. We also demonstrate the benefit of combining this treatment with a conventional parenteral

  7. Dose assessment for inhalation intakes in complex, energetic environments: experience from the US Capstone study

    International Nuclear Information System (INIS)

    Guilmette, Raymond A.; Parkhurst, Mary Ann

    2007-01-01

    Because of the lack of existing information needed to evaluate the risks from inhalation exposures to depleted uranium (DU) aerosols of US soldiers during the 1991 Persian Gulf War, the US Department of Defense funded an experimental study to measure the characteristics of DU aerosols created when Abrams tanks and Bradley fighting vehicles are struck with large-caliber DU penetrators, and a dose and risk assessment for individuals present in such vehicles. This paper describes some of the difficulties experienced in dose assessment modelling of the very complex DU aerosols created in the Capstone studies, e.g. high concentrations, heterogeneous aerosol properties, non-lognormal particle size distributions, triphasic in vitro dissolution and rapid time-varying functions of both DU air concentration and particle size. The approaches used to solve these problems along with example results are presented. (authors)

  8. Toxicity of inhaled 239PuO2 in immature beagle dogs

    International Nuclear Information System (INIS)

    Guilmette, R.A.; Muggenburg, B.A.; Hahn, F.F.; Mauderly, J.L.; Boecker, B.B.; McClellan, R.O.

    1980-01-01

    Immature beagle dogs have been exposed by inhalation to a 1.5 μm aerodynamic diameter monodisperse aerosol of 239 PuO 2 to compare the biological effects with those seen in young adult and aged dogs exposed to a similar aerosol. To date, 18 dogs have been exposed to the aerosol, resulting in graded initial lung burdens ranging from 0.003 to 0.38 μCi/kg body weight. Two dogs have been exposed to the aerosol diluent and serve as controls. Two of the 18 exposed animals were sacrificed 8 days after exposure to provide information on initial deposition and distribution. All other exposed animals are alive 400 days after exposure. No dogs were exposed during the past year because of an outbreak of canine parvovirus enteritis which caused death in 8 to 10 week-old dogs

  9. Receptor models for source apportionment of remote aerosols in Brazil

    International Nuclear Information System (INIS)

    Artaxo Netto, P.E.

    1985-11-01

    The PIXE (particle induced X-ray emission), and PESA (proton elastic scattering analysis) method were used in conjunction with receptor models for source apportionment of remote aerosols in Brazil. The PIXE used in the determination of concentration for elements with Z >- 11, has a detection limit of about 1 ng/m 3 . The concentrations of carbon, nitrogen and oxygen in the fine fraction of Amazon Basin aerosols was measured by PESA. We sampled in Jureia (SP), Fernando de Noronha, Arembepe (BA), Firminopolis (GO), Itaberai (GO) and Amazon Basin. For collecting the airbone particles we used cascade impactors, stacked filter units, and streaker samplers. Three receptor models were used: chemical mass balance, stepwise multiple regression analysis and principal factor analysis. The elemental and gravimetric concentrations were explained by the models within the experimental errors. Three sources of aerosol were quantitatively distinguished: marine aerosol, soil dust and aerosols related to forests. The emission of aerosols by vegetation is very clear for all the sampling sites. In Amazon Basin and Jureia it is the major source, responsible for 60 to 80% of airborne concentrations. (Author) [pt

  10. Precision and accuracy of β gauge for aerosol mass determinations

    International Nuclear Information System (INIS)

    Courtney, W.J.; Shaw, R.W.; Dzabay, T.G.

    1982-01-01

    Results of an experimental determination of the precision and the accuracy of a β-ray attenuation method for measurement of aerosol mass are presented. The instrumental precision for a short-term experiment was 25 μg for a 6.5-cm 2 deposit collected on approximately 1 mg/cm 2 Teflon filters; for a longer-term experiment the precision was 27 μg. The precision of the gravimetric determinations of aerosol deposits was 22 μg for Teflon filters weighed to 1 μg. Filter reorientation and air density changes that were able adversely to affect the β-ray attenuation results are discussed. β-ray attenuation results are in good agreement with gravimetric measurements on the same filter-collected aerosols. Using dichotomous samplers in Durham, NC, we collected 136 aerosol samples on Teflon filters in two size ranges. A regression line was calculated implicitly assuming errors in both measurements of mass. The 90% confidence intervals lay within 21 μg of the regression line for mean fine fraction aerosol mass loadings of 536 μg and within 19 μg of the regression line for mean coarse fraction aerosol mass loadings of 349 μg. Any bias between gravimetric and β-gauge mass measurements was found to be less than 5%

  11. Intermittent aerosol delivery to the lungs during high-flow nasal cannula therapy.

    Science.gov (United States)

    Golshahi, Laleh; Longest, P Worth; Azimi, Mandana; Syed, Aamer; Hindle, Michael

    2014-10-01

    Use of submicrometer particles combined with condensational growth techniques has been proposed to reduce drug losses within components of high-flow nasal cannula therapy systems and to enhance the dose reaching the lower respiratory tract. These methods have been evaluated using continuous inhalation flow rather than realistic inhalation/exhalation breathing cycles. The goal of this study was to evaluate in vitro aerosol drug delivery using condensational growth techniques during high-flow nasal cannula therapy using realistic breathing profiles and incorporating intermittent aerosol delivery techniques. A mixer-heater combined with a vibrating mesh nebulizer was used to generate a submicrometer aerosol using a formulation of 0.2% albuterol sulfate and 0.2% sodium chloride in water. Delivery efficiency of the aerosol for 1 min through a nasal cannula was considered using an intermittent delivery regime with aerosol being emitted for either the entire inhalation time (2 s) or half of the inhalation period (1 s) and compared with continuous delivery. The deposition of the aerosol was evaluated in the nasal delivery components (ventilator tubing and cannula) and an in vitro adult nose-mouth-throat (NMT) model using 3 realistic breathing profiles. Significant improvements in dose delivered to the exit of the NMT model (ex-NMT) were observed for both condensational growth methods using intermittent aerosol delivery compared with continuous delivery, and increasing the tidal volume was found useful. The combination of the largest tidal volume with the shortest intermittent delivery time resulted in the lowest respiration losses and the highest ex-NMT delivered dose. Intermittent aerosol delivery using realistic breathing profiles of submicrometer condensational growth aerosols was found to be efficient in delivering nasally administered drugs in an in vitro airway model. Copyright © 2014 by Daedalus Enterprises.

  12. Hemodynamic effects of aerosol propellants. I. Cardiac depression in the dog.

    Science.gov (United States)

    Simaan, J A; Aviado, D M

    1975-11-01

    The inhalation of fluorocarbons caused a depression of myocardial contractility, aortic hypotension, a decrease in cardiac output and an increase in pulmonary vascular resistance. The minimal concentrations that elicited these changes are as follows: 1% trichlorofluoromethane (FC11); 2.5% dichlorotetrafluoroethane (FC114); and 10% dichlorodifluoromethane (FC12). Inhalation of 20% octafluorocyclobutane (FC318) and difluoroethane (FC152a) did not influence these hemodynamic parameters. As in previous comparisons, the most widely used aerosol propellants are potentially cardiotoxic in the anesthetized dog.

  13. Theophylline Cocrystals Prepared by Spray Drying: Physicochemical Properties and Aerosolization Performance

    OpenAIRE

    Alhalaweh, Amjad; Kaialy, Waseem; Buckton, Graham; Gill, Hardyal; Nokhodchi, Ali; Velaga, Sitaram P.

    2013-01-01

    The purpose of this work was to characterize theophylline (THF) cocrystals prepared by spray drying in terms of the physicochemical properties and inhalation performance when aerosolized from a dry powder inhaler. Cocrystals of theophylline with urea (THF-URE), saccharin (THF-SAC) and nicotinamide (THF-NIC) were prepared by spray drying. Milled THF and THF-SAC cocrystals were also used for comparison. The physical purity, particle size, particle morphology and surface energy of the materials ...

  14. Assessment of anthropogen aerosols : influence on environment and human health

    International Nuclear Information System (INIS)

    Kwasny, F.

    2010-01-01

    The term aerosol describes a dispersion of liquid or solid particles in a gaseous medium, usually including particles at a size ranging from 0.001 to 100 μm. The size of an aerosol's particle is of special interest, as it influences its fate. Together with other physical properties like shape, density and mass of the particles, it defines the aerosol's possibilities of sedimentation, diffusion, dispersion, coagulation or impaction onto surfaces. As aerosols are by definition composed of a number of particles, this regime of constituent parts varies. Aerosols are well known with their common names such as dust, smoke, fume, fog, mist, spray or haze. The projects of this thesis deal with different aspects of anthropogenic aerosols. We investigated their influence on human health and environmental impact by looking at particle concentrations and size distributions of aerosols. Ultimately, we examined their fate in a human lung model to reveal a direct influence on humans. Our studies included brine inhalation at an open-air spa, exposure to ultrafine particles while driving a car through a heavy impacted environment, and the influence of aerosols on spectators while watching fireworks. In a project with the local environmental authorities we investigated the correlation of air quality, meteorological and traffic data with ultrafine particles. Resulting from our studies, we found beneficial effects of salt aerosols used for inhalation therapy, showing the positive influence in lung deposition, as well as, an effect on ultrafine particle inventory of the ambient air. Combustion aerosols and other man-made particulate matter proved to have adverse effects on human lung deposition, allowing ultrafine particles to reach deep into the human lung. This not only poses a threat to respiratory organs; particles can be translocated from the respiratory tract into the blood stream and from there to other organs, affecting the entire body. For the purpose of finding reasonable

  15. Toxicity studies of inhaled beta-emitting radionuclides - Status report

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, F F; Boeker, B B; Gillett, N A; Griffith, W C; Lundgren, D L; McClellan, R O; Muggenburg, B A; Snipes, M B

    1988-12-01

    The effects of beta-emitting radionuclides inhaled in either a relatively soluble form ({sup 90}SrCl{sub 2}, {sup 144}CeCl{sub 3}, {sup 91}yl{sub 3}, or {sup 137}CsCl) or in a relatively insoluble form ({sup 90}Y, {sup 91}Y, {sup 144}Ce or {sup 90}Sr in fused aluminosilicate particles [FAP]) have been studied in laboratory animals. The results showed that the total beta dose and the dose-rate pattern can modify both the neoplastic and non-neoplastic effects of inhaled beta-emitting radionuclides. In addition, the solubility and chemical characteristics of the radionuclides influence which organs are affected. Effects are seen primarily in organs where the radionuclide is ultimately accumulated, e.g., lung, bone, liver, or tracheobronchial lymph nodes. In addition, effects may be seen in organs where there is little accumulation, but where the radiation dose may still be high, e.g., nasal epithelium and heart. Studies of inhaled {sup 144}Ce-FAP in four different species showed that, compared to mice and dogs, lung tumor risk factors are very low for Syrian hamsters and high for rats. Studies of mice, Syrian hamsters, rats, and dogs repeatedly exposed to aerosols of {sup 144}Ce-FAP showed that lung tumor incidence correlates better with cumulative dose to the lung than with dose rate. Most of the studies in this program are nearing completion and full analyses are in progress. (author)

  16. Organ dose from inhaled radionuclides taking lull period into account

    International Nuclear Information System (INIS)

    Datta, S.

    1982-01-01

    The dosimetry of inhaled radionuclides is generally carried out in accordance with the lung model recommended by the ICRP Task Group on Lung Dynamics. The relevant expressions are integrated over a given period, assuming continuous inhalation in an atmosphere of constant aerosol concentration. Though for the same amount of intake the dose commitment is found to be independent of variations in the rate of intake, the dose determined over specific intervals of time, is influenced by it or by lull intervals therein. Formulae are developed to arrive at doses to different organs when the subject's intake is constant and continuous for 8 hours, followed by a lull period of 16 hours each day. Results are given for a number of radionuclides and are compared with values characteristic of continuous inhalation. It is observed that when exposure is assumed to be continuous the dose for the same intake of activity is underestimated as compared to the dose when lull period is taken into account. For working periods of 6 days and 30 days the underestimate ranges from 5%-20% and 0.6% to 4.5% respectively. (author)

  17. Toxicity of inhaled Ca-DTPA in the beagle dog

    International Nuclear Information System (INIS)

    Smith, V.H.; Ragan, H.A.; Lund, J.E.; Hackett, P.L.

    1975-01-01

    There are several advantages to the administration of Ca- DTPA by inhalation rather than intravenous drip for the decorporation of certain radionuclides. Among these are the possibility of treating very promptly following an accidental incorporation to achieve maximum treatment effectiveness and convenince for medical management, even to the extent that treatment can be self-administered. The present investigational New Drug permit allows treatment of humans only by the intravenous route and animal studies are required to justify the new route. Earlier work in rats and hamsters showed five successive daily inhalations of Ca-DTPA aerosols (dose 1 to 4 times human i.v. dose) produced a transitory emphysema in 17/40 rats serially sacrificed up to 3 weeks following the last exposure and in 10/20 hamsters up to 1 week after exposure. No emphysema was seen in rats sacrificed after 3 weeks and in hamsters after 1 week following the exposures. Results of tests in dogs administered DTPA by inhalation showed hyperplasia of the gastric submucosal lymphoid follicles observed 1 week following the last exposure may be treatment-related, but other observed changes were considered unrelated. (U.S.)

  18. The effects of ambient conditions on the passive dust sampler when used in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Hemingway, M.; Thorpe, A.

    1998-09-01

    A previous feasibility study of the Health and Safety Laboratory (HSL) electret-based passive dust sampler carried out during site sampling in coal mines showed that the measurements made with the passive sampler and those made with the MRE sampler correlated well in each of two mines, but the ratios of samples obtained with the passive sampler and the MRE sampler in the two mines were different. This means the passive sampler would need a separate calibration for each coal mine in which it was used. Laboratory tests and further underground trials were carried out to quantify the possible effects of temperature and humidity on ratios. The passive dust samplers used at Maltby Colliery in the UK were found to pass the acceptance criteria according to the CEN standard for the assessment of the performance of instruments for the measurement of airborne particles, provided that samplers exposed when coal was not being cut were not included in the analysis. Temperature and relative humidity slightly affected the behaviour of the passive sampler during laboratory trials and relative humidity was found to possibly affect the behaviour during field trials. Ventilation rates had no effect on the passive sampler behaviour but the orientation of the passive dust sampler with respect to air flow affected the behaviour during laboratory trials. Further work is needed to quantify effects. 7 refs., 14 figs., 3 tabs.

  19. Effects of current inhalation exposure methods on cardiopulmonary function of immature dogs

    International Nuclear Information System (INIS)

    Mauderly, J.A.; Muggenburg, B.A.; Lay, J.C.

    1976-01-01

    Approximately 9% of 84 3-mo-old dogs exposed to inhalation of radioactive aerosols have experienced respiratory failure during exposure. A study was conducted to evaluate effects of exposure on cardiopulmonary function of immature dogs. Results indicate that the combination of nose breathing and breathing into the aerosol delivery cone quadrupled breathing effort of 3-mo-old dogs. Excitement exacerbated a failure to maintain adequate alveolar ventilation and resulted in CO 2 retention and acidosis. General anesthesia and use of an endotracheal tube alleviated problems due to nasal airflow resistance and behaviorally-related increases in ventilatory requirement

  20. Aerosol scrubbers

    International Nuclear Information System (INIS)

    Sheely, W.F.

    1986-01-01

    The Submerged Gravel Scrubber is an air cleaning system developed by the Department of Energy's Liquid Metal Reactor Program. The Scrubber System has been patented by the Department of Energy. This technology is being transferred to industry by the DOE. Its basic principles can be adapted for individual applications and the commercialized version can be used to perform a variety of tasks. The gas to be cleaned is percolated through a continuously washed gravel bed. The passage of the gas through the gravel breaks the stream into many small bubbles rising in a turbulent body of water. These conditions allow very highly efficient removal of aerosols from the gas

  1. Calibration of aerosol radiometers. Special aerosol sources

    International Nuclear Information System (INIS)

    Belkina, S.K.; Zalmanzon, Yu.E.; Kuznetsov, Yu.V.; Fertman, D.E.

    1988-01-01

    Problems of calibration of artificial aerosol radiometry and information-measurement systems of radiometer radiation control, in particular, are considered. Special aerosol source is suggested, which permits to perform certification and testing of aerosol channels of the systems in situ without the dismantling

  2. Modeling Inhalational Tularemia: Deliberate Release and Public Health Response

    Science.gov (United States)

    Hall, Ian M.; Leach, Steve

    2011-01-01

    Two epidemic modeling studies of inhalational tularemia were identified in the published literature, both demonstrating the high number of potential casualties that could result from a deliberate aerosolized release of the causative agent in an urban setting. However, neither study analyzed the natural history of inhalational tularemia nor modeled the relative merits of different mitigation strategies. We first analyzed publicly available human/primate experimental data and reports of naturally acquired inhalational tularemia cases to better understand the epidemiology of the disease. We then simulated an aerosolized release of the causative agent, using airborne dispersion modeling to demonstrate the potential number of casualties and the extent of their spatial distribution. Finally, we developed a public health intervention model that compares 2 mitigation strategies: targeting antibiotics at symptomatic individuals with or without mass distribution of antibiotics to potentially infected individuals. An antibiotic stockpile that is sufficient to capture all areas where symptomatic individuals were infected is likely to save more lives than treating symptomatic individuals alone, providing antibiotics can be distributed rapidly and their uptake is high. However, with smaller stockpiles, a strategy of treating symptomatic individuals alone is likely to save many more lives than additional mass distribution of antibiotics to potentially infected individuals. The spatial distribution of symptomatic individuals is unlikely to coincide exactly with the path of the dispersion cloud if such individuals are infected near their work locations but then seek treatment close to their homes. The optimal mitigation strategy will depend critically on the size of the release relative to the stockpile level and the effectiveness of treatment relative to the speed at which antibiotics can be distributed. PMID:22044315

  3. Understanding pressurized metered dose inhaler performance.

    Science.gov (United States)

    Ivey, James W; Vehring, Reinhard; Finlay, Warren H

    2015-06-01

    Deepening the current understanding of the factors governing the performance of the pressurized metered dose inhaler (pMDI) has the potential to benefit patients by providing improved drugs for current indications as well as by enabling new areas of therapy. Although a great deal of work has been conducted to this end, our knowledge of the physical mechanisms that drive pMDI performance remains incomplete. This review focuses on research into the influence of device and formulation variables on pMDI performance metrics. Literature in the areas of dose metering, atomization and aerosol evolution and deposition is covered, with an emphasis on studies of a more fundamental nature. Simple models which may be of use to those developing pMDI products are summarized. Although researchers have had good success utilizing an empirically developed knowledge base to predict pMDI performance, such knowledge may not be applicable when pursuing innovations in device or formulation technology. Developing a better understanding of the underlying mechanisms is a worthwhile investment for those working to enable the next generation of pMDI products.

  4. In Vitro Tests for Aerosol Deposition. V: Using Realistic Testing to Estimate Variations in Aerosol Properties at the Trachea.

    Science.gov (United States)

    Wei, Xiangyin; Hindle, Michael; Delvadia, Renishkumar R; Byron, Peter R

    2017-10-01

    The dose and aerodynamic particle size distribution (APSD) of drug aerosols' exiting models of the mouth and throat (MT) during a realistic inhalation profile (IP) may be estimated in vitro and designated Total Lung Dose, TLD in vitro , and APSD TLDin vitro , respectively. These aerosol characteristics likely define the drug's regional distribution in the lung. A general method was evaluated to enable the simultaneous determination of TLD in vitro and APSD TLDin vitro for budesonide aerosols' exiting small, medium and large VCU-MT models. Following calibration of the modified next generation pharmaceutical impactor (NGI) at 140 L/min, variations in aerosol dose and size exiting MT were determined from Budelin ® Novolizer ® across the IPs reported by Newman et al., who assessed drug deposition from this inhaler by scintigraphy. Values for TLD in vitro from the test inhaler determined by the general method were found to be statistically comparable to those using a filter capture method. Using new stage cutoffs determined by calibration of the modified NGI at 140 L/min, APSD TLDin vitro profiles and mass median aerodynamic diameters at the MT exit (MMAD TLDin vitro ) were determined as functions of MT geometric size across Newman's IPs. The range of mean values (n ≥ 5) for TLD in vitro and MMAD TLDin vitro for this inhaler extended from 6.2 to 103.0 μg (3.1%-51.5% of label claim) and from 1.7 to 3.6 μm, respectively. The method enables reliable determination of TLD in vitro and APSD TLDin vitro for aerosols likely to enter the trachea of test subjects in the clinic. By simulating realistic IPs and testing in different MT models, the effects of major variables on TLD in vitro and APSD TLDin vitro may be studied using the general method described in this study.

  5. Bronchial and pulmonary scintigraphy with radioactively marked aerosols

    International Nuclear Information System (INIS)

    Wuerstle, T.

    1982-01-01

    In 97 patients with bronchitis, bronchial asthma, tuberculosis, sarcoidosis, pneumoconiosis, or tumors the mucociliary clearance and/or deposit pattern after inhalation of radioactively marked aerosols (1 mCi 99m Tc sulfur colloid) was studied. Normal values of the mucociliary 30 min. clearance for the central bronchial/lung periphery are 21%/15%. There was a decreased clearance with bronchitis (11/8%), bronchial asthma, emphysema, tuberculosis, sarcoidosis, trachiobronchial amyloidosis, pleural scarring or interstitial pneumona. Increased clearance (29/19%) was shown with pneumoconiosis. The correlation of deposit pattern and disease, for example, bronchitis, bronchial asthma, bullous emphysema, pleural scarring, partial lung resection, bronchopneumonia, or bronchial restriction, is described. In comparison of aerosol scintigraphy to perfusion scintigraphy and ventilation with gaseous xenon, the aerosol scintigraphy is superior to xenon for certain indications. The aerosol particles, which are larger in comparison to xenon, settle easier by obstructions or flow variations and thereby give better clinical indications of regional differences. (orig.) [de

  6. A Novel Fireball Analysis for an Explosive Aerosolization Study

    International Nuclear Information System (INIS)

    Sharon, A.; Halevy, I.; Sattinger, D.; Banaim, P.; Yaar, I.; Krantz, L.; Pinhas, M.

    2014-01-01

    The final consequent risk following an explosion of radiological dispersal device (RDD) is highly depends on final radioactive particles’ size distribution creates by detonation shock wave. Respirable, aerosols contribute to risk in a different way when compare it to non respirable aerosols or to ballistic, inertial, particles or even larger fragments. While aerosols (both, respirable and non respirable) are moving downwind with the cloud, heavier, inertial particles escape the initial fireball and deposited on the ground at a short distances from the ground zero (GZ) point. Respirable aerosols are risky when inhaled into the body (internal radiation) while non respirable have risk as an external exposure on the skin and from a distance. Hence, knowing the size distribution of the radioactive particles will, thus, enable more realistic risk assessment predictions. We show here that detonation fireball fast multispectral radiometrycan be a novel tool that can be indicative to the final particles size distribution

  7. Fast Multispectral Fireball Analyses and the Relation to Particles’ Aerosolization

    International Nuclear Information System (INIS)

    Sharon, A.; Halevy, I.; Sattinger, D.; Berenstein, Z.; Neuman, R.; Banaim, P.; Pinhas, M.; Yaar, I.

    2014-01-01

    One of the key questions in analyzing the consequent risk following an explosion of radiological dispersal device (RDD) is the final radioactive particles’ size distribution caused by the detonation. Fine, respirable, aerosols behave different when compare it to large, non respirable, aerosols or to inertial particles. While aerosols (both, respirable and non respirable) are trapped inside the detonation cloud moving downwind with the cloud, heavier, inertial particles escape the initial fireball and settled on the ground at a short distances due to hydrodynamic drug. Respirable aerosols are mostly risky when inhaled into the body (internal radiation) while non respirable are risky as an external exposure agents (both on the skin and from a distance). Knowing the size distribution of the radioactive particles will, thus, enable more realistic risk assessment predictions of such events. Fast multispectral radiometry of detonation fireballs can be used as novel tool for the estimation of the RA material final size distribution

  8. Which inhaled corticosteroid and long-acting β-agonist combination is better in patients with moderate-to-severe asthma, a dry powder inhaler or a pressurized metered-dose inhaler?

    Science.gov (United States)

    Muraki, Masato; Gose, Kyuya; Hanada, Soichiro; Sawaguchi, Hirochiyo; Tohda, Yuji

    2017-11-01

    Two main types of devices are used to facilitate the administration of inhaled corticosteroid (ICS) and long-acting β-agonist (LABA) in combination, dry powder inhalers (DPIs) and pressurized metered-dose inhalers (pMDIs). There are few reports comparing the effects of the two devices, and it is unknown which should be recommended for asthma patients with given sets of characteristics. In the current study, the beneficial effects and side effects associated with DPIs and pMDIs were compared, and the question of which device should be recommended for asthma patients was investigated. A prospective, randomized, crossover, comparative study in adult outpatients with asthma was conducted using salmeterol/fluticasone propionate combination (SFC) 50 μg/250 μg, one inhalation of Adoair ® 250 Diskus ® twice daily or two inhalations of Adoair ® 125 Aerosol twice daily, for 8 weeks. Questionnaires, exhaled nitric oxide (FeNO) tests and pulmonary function tests were administered after the use of each device for 8 weeks, and the results derived from each device were compared. Sixty-eight subjects were included in the final analysis. There were no significant differences between quality-of-life scores, FeNO, spirometry test results and forced oscillation results. With regard to patient preferences, 57.4% preferred the Adoair ® Aerosol and 35.3% preferred the Adoair ® Diskus ® , as determined via the comparative evaluation questionnaire. Although DPI prescription accounts for the predominant market share of combined ICS/LABA in Japan, patients preferred a pMDI device to a DPI device. Compared to DPIs, pMDIs may be the preferential choice for patients with asthma.

  9. Aerosols and the lungs

    International Nuclear Information System (INIS)

    1987-01-01

    The lectures of the colloquium are discussed in summary form. There were 5 lectures on aerosol deposition, 5 on aerosol elimination, 7 on toxicology, and 7 on the uses of aerosols in medical therapy. In some cases aerosols with radioactive labels were used. Several lectures reviewed the kinetics and toxicology of airborne environmental pollutants. (MG) [de

  10. Distribution, retention and early cytogenetic damage in Cynomolgus monkeys following inhalation of 239Pu(NO3)4

    International Nuclear Information System (INIS)

    Brooks, A.L.; Mewhinney, J.A.; Redman, H.C.; Guilmette, R.A.; McClellan, R.O.

    1980-01-01

    Sixteen Cynomolgus monkeys were exposed by inhalation to an aerosol of 239 Pu(NO 3 ) 4 which resulted in calculated initial lung burdens of 1.0, 0.3 and 0.1 μCi. Four animals were exposed to the carrier aerosol and served as controls. Animals were sacrificed at 4 days and 45 days after exposure to determine the distribution and retention of the aerosol. The amount of plutonium in the liver, skeleton and testes increased as a function of time after exposure. Two monkeys died 155 and 188 days after inhalation exposure from radiation pneumonitis and fibrosis. There was a doubling of the total chromosome aberration frequency in the blood lymphocytes and a significant increase in dicentric chromosomes in the animals exposed for 6 months to initial lung burdens of 1.0 μCi

  11. A nonhuman primate aerosol deposition model for toxicological and pharmaceutical studies

    Energy Technology Data Exchange (ETDEWEB)

    Martonen, T.B.; Katz, I.M.; Musante, C.J. [US EPA, Research Triangle Park, NC (USA)

    2001-07-01

    Nonhuman primates may be used as human surrogates in inhalation exposure studies to assess either the (1) adverse health effects of airborne particulate matter or (2) therapeutic effects of aerosolized drugs and proteins. Mathematical models describing the behavior and fate of inhaled aerosols may be used to complement such laboratory investigations. In this work a mathematical description of the rhesus monkey (Macaca mulatta) lung is presented for use with an aerosol deposition model. Deposition patterns of 0.01- to 5-{mu}m-diameter monodisperse aerosols within lungs were calculated for 3 monkey lung models (using different descriptions of alveolated regions) and compared to human lung results obtained using a previously validated mathematical model of deposition physics. The findings suggest that there are significant differences between deposition patterns in monkeys and humans. The nonhuman primates had greater exposures to inhaled substances, particularly on the basis of deposition per unit airway surface area. However, the different alveolar volumes in the rhesus monkey models had only minor effects on aerosol dosimetry within those lungs. By being aware of such quantitative differences, investigators can employ the respective primate models (human and nonhuman) to more effectively design and interpret the results of future inhalation exposure experiments.

  12. Toxicity of inhaled 238PuO2 II

    International Nuclear Information System (INIS)

    Muggenburg, B.A.; Mewhinney, J.A.; Merickel, B.S.; Boecker, B.B.; Hahn, F.F.; Guilmette, R.A.; Mauderly, J.L.; McClellan, R.O.

    1980-01-01

    Studies are in progress to determine dose-response relationships for inhaled 238 PuO 2 . Beagle dogs were given a single, brief, nose-only inhalation exposure to aerosols of monodisperse particles of 238 PuO 2 . Aerosols of two sizes were used, 1.5 μm aerodynamic diameter (AD) and 3.0 μm AD. Dogs were exposed to achieve initial lung burdens of 0.56, 0.28, 0.14, 0.07, 0.03 or 0.01 μCi 238 PuO 2 /kg body weight. Twelve dogs were exposed at each activity level to each aerosol particle size. The local dose around each 3.0 μm AD particle was 10 times higher than the local dose around 1.5 μm AD particles, but the dose averaged over the whole lung was the same at each activity level for both particle sizes. The lung retention of 238 Pu was divided into two phases of clearance. During the first 100 days after exposure, the average retention half-time for 238 Pu in the lung was 310 days. When the solubility changed due to particle breakup, the retention half-time decreased to 180 days during the period from 1OO to 1,500 days after exposure. The first biological effects observed were lymphopenia and neutropenia in peripheral blood. To date, 28 Beagle dogs have died at times from 536 to 1683 days after exposure. Initial lung burdens for the dead dogs ranged from 0.18 to 2.2 μCi 238 Pu/kg body weight. Nine died with radiation pneumonitis and pulmonary fibrosis, 10 died with lung tumors and 19 dogs died with bone tumors. There are 116 exposed and 22 control dogs surviving and under observation. Current patterns of dose versus response are discussed. (author)

  13. Biological clearance and committed dose equivalent in pulmonary region from inhaled radioaerosols for lung scanning

    Energy Technology Data Exchange (ETDEWEB)

    Soni, P.S.; Sharma, S.M.; Raghunath, B.; Somasundaram, S.

    1987-01-01

    Biological clearance half-lives (Tsub(b)) of different /sup 99/Tcsup(m)-labelled compounds from each lung have been determined, after administering the radioaerosol to normal subjects using the BARC dry aerosol generation and inhalation system. Based on these experimental clearance half-lives, the committed dose equivalent to the lungs has been computed using both the ICRP lung model and MIRD-11 values.

  14. Biological clearance and committed dose equivalent in pulmonary region from inhaled radioaerosols for lung scanning

    International Nuclear Information System (INIS)

    Soni, P.S.; Sharma, S.M.; Raghunath, B.; Somasundaram, S.

    1987-01-01

    Biological clearance half-lives (Tsub(b)) of different 99 Tcsup(m)-labelled compounds from each lung have been determined, after administering the radioaerosol to normal subjects using the BARC dry aerosol generation and inhalation system. Based on these experimental clearance half-lives, the committed dose equivalent to the lungs has been computed using both the ICRP lung model and MIRD-11 values. (author)

  15. Effect of inhaled formyl-methionyl-leucyl-phenylalanine on airway function.

    OpenAIRE

    Berend, N; Peters, M J; Armour, C L; Black, J L; Ward, H E

    1988-01-01

    Formyl-methionyl-leucyl-phenylalanine (FMLP), a synthetic, acylated tripeptide analogous to bacterial chemotactic factors, has been shown to cause bronchoconstriction in guinea pig, rabbit, and human airways in vitro. To determine whether FMLP causes bronchoconstriction in man in vivo, a preliminary study was undertaken in which five non-smokers (mean age 35 years, FEV1 94% (SEM 5%) predicted) and five smokers (mean age 34 years, FEV1 93% (6%) predicted) inhaled aerosols of FMLP. None of the ...

  16. Jet Fuel Kerosene is not Immunosuppressive in Mice or Rats Following Inhalation for 28 Days

    OpenAIRE

    White, Kimber L.; DeLorme, Michael P.; Beatty, Patrick W.; Smith, Matthew J.; Peachee, Vanessa L.

    2013-01-01

    Previous reports indicated that inhalation of JP-8 aviation turbine fuel is immunosuppressive. However, in some of those studies, the exposure concentrations were underestimated, and percent of test article as vapor or aerosol was not determined. Furthermore, it is unknown whether the observed effects are attributable to the base hydrocarbon fuel (jet fuel kerosene) or to the various fuel additives in jet fuels. The present studies were conducted, in compliance with Good Laboratory Practice (...

  17. Experiment for ambulatory inhalation rehabilitation of occupational dust-radiation injuries of the respiratory system

    International Nuclear Information System (INIS)

    Ivanov, Z.; Nikolova, M.E.; Todorov, A.; Kuteva, E.

    1984-01-01

    An experiment was carried out for ambulatory inhalation rehabilitation on a group of 172 subjects with pronounced injuries of the respiratory system. Parallely with them was a rehabilitated group of 8 pensioners. Because of the specific nature of the production etiopathogenetic complex including inhalation introduced radioactive and stable aerosols and their uninterrupted action during rehabilitation, the experiment conducted is of special importance for the perspective elaboration and implementation of health measures in a numerous contingent of workers in industrial important branches without discontinuing work. A positive effect was obtained in 54,2% of the treated non-smokers. No improvement was found of the objective ventilation indices of respiration in smokers and pensioners. As far as physical and anamnestic indices are concerned, such as rales, cough, dyspnea, pains in the chest etc., there was impovement in all treated subjects. Finally, some conclusions are drawn about the future trends of inhalation prophylaxis in the respective branches of production

  18. Characteristics of regional aerosols: Southern Arizona and eastern Pacific Ocean

    Science.gov (United States)

    Prabhakar, Gouri

    Atmospheric aerosols impact the quality of our life in many direct and indirect ways. Inhalation of aerosols can have harmful effects on human health. Aerosols also have climatic impacts by absorbing or scattering solar radiation, or more indirectly through their interactions with clouds. Despite a better understanding of several relevant aerosol properties and processes in the past years, they remain the largest uncertainty in the estimate of global radiative forcing. The uncertainties arise because although aerosols are ubiquitous in the Earth's atmosphere they are highly variable in space, time and their physicochemical properties. This makes in-situ measurements of aerosols vital in our effort towards reducing uncertainties in the estimate of global radiative forcing due to aerosols. This study is an effort to characterize atmospheric aerosols at a regional scale, in southern Arizona and eastern Pacific Ocean, based on ground and airborne observations of aerosols. Metals and metalloids in particles with aerodynamic diameter (Dp) smaller than 2.5 μm are found to be ubiquitous in southern Arizona. The major sources of the elements considered in the study are identified to be crustal dust, smelting/mining activities and fuel combustion. The spatial and temporal variability in the mass concentrations of these elements depend both on the source strength and meteorological conditions. Aircraft measurements of aerosol and cloud properties collected during various field campaigns over the eastern Pacific Ocean are used to study the sources of nitrate in stratocumulus cloud water and the relevant processes. The major sources of nitrate in cloud water in the region are emissions from ships and wildfires. Different pathways for nitrate to enter cloud water and the role of meteorology in these processes are examined. Observations of microphysical properties of ambient aerosols in ship plumes are examined. The study shows that there is an enhancement in the number

  19. Comparison. US P-61 and Delft sediment samplers

    Science.gov (United States)

    Beverage, Joseph P.; Williams, David T.

    1990-01-01

    The Delft Bottle (DB) is a flow-through device designed by the Delft Hydraulic Laboratory (DHL), The Netherlands, to sample sand-sized sediment suspended in streams. The US P-61 sampler was designed by the Federal Interagency Sedimentation Project (FISP) at the St. Anthony Falls Hydraulic Laboratory, Minneapolis, Minnesota, to collect suspended sediment from deep, swift rivers. The results of two point-sampling tests in the United States, the Mississippi River near Vicksburg, Mississippi, in 1983 and the Colorado River near Blythe, California, in 1984, are provided in this report. These studies compare sand-transport rates, rather than total sediment-transport rates, because fine material washes through the DB sampler. In the United States, the commonly used limits for sand-sized material are 0.062 mm to 2.00 mm (Vanoni 1975).

  20. Atmospheric aerosol in an urban area: Comparison of measurement instruments and methodologies and pulmonary deposition assessment; Aerosol atmosferico in area urbanae di misura e valutazione di deposizione polmonare

    Energy Technology Data Exchange (ETDEWEB)

    Berico, M; Luciani, A; Formignani, M [ENEA, Centro Ricerche Bologna (Italy). Dip. Ambiente

    1996-07-01

    In March 1995 a measurement campaign of atmospheric aerosol in the Bologna urban area (Italy) was carried out. A transportable laboratory, set up by ENEA (Italian national Agency for New Technologies, Energy and the Environment) Environmental Department (Bologna), was utilized with instruments for measurement of atmospheric aerosol and meteorological parameters. The aim of this campaign was of dual purpose: to characterize aerosol in urban area and to compare different instruments and methodologies of measurements. Mass concentrations measurements, evaluated on a 23-hour period with total filter, PM10 dichotomous sampler and low pressure impactor (LPI Berner), have provided information respectively about total suspended particles, respirable fraction and granulometric parameters of aerosol. Eight meteorologic parameters, number concentration of submicromic fraction of aerosol and mass concentration of micromic fraction have been continually measured. Then, in a daytime period, several number granulometries of atmospheric aerosol have also been estimated by means of diffusion battery system. Results related to different measurement methodologies and granulometric characteristics of aerosol are presented here. Pulmonary deposition of atmospheric aerosol is finally calculated, using granulometries provided by LPI Brener and ICRP 66 human respiratory tract model.

  1. Prediction of acute inhalation toxicity using in vitro lung surfactant inhibition.

    Science.gov (United States)

    Sørli, Jorid B; Huang, Yishi; Da Silva, Emilie; Hansen, Jitka S; Zuo, Yi Y; Frederiksen, Marie; Nørgaard, Asger W; Ebbehøj, Niels E; Larsen, Søren T; Hougaard, Karin S

    2018-01-01

    Private consumers and professionals may experience acute inhalation toxicity after inhaling aerosolized impregnation products. The distinction between toxic and non-toxic products is difficult to make for producers and product users alike, as there is no clearly described relationship between the chemical composition of the products and induction of toxicity. The currently accepted method for determination of acute inhalation toxicity is based on experiments on animals; it is time-consuming, expensive and causes stress for the animals. Impregnation products are present on the market in large numbers and amounts and exhibit great variety. Therefore, an alternative method to screen for acute inhalation toxicity is needed. The aim of our study was to determine if inhibition of lung surfactant by impregnation products in vitro could accurately predict toxicity in vivo in mice. We tested 21 impregnation products using the constant flow through set-up of the constrained drop surfactometer to determine if the products inhibited surfactant function or not. The same products were tested in a mouse inhalation bioassay to determine their toxicity in vivo. The sensitivity was 100%, i.e., the in vitro method predicted all the products that were toxic for mice to inhale. The specificity of the in vitro test was 63%, i.e., the in vitro method found three false positives in the 21 tested products. Six of the products had been involved in accidental human inhalation where they caused acute inhalation toxicity. All of these six products inhibited lung surfactant function in vitro and were toxic to mice.

  2. Deposition and clearance of inhaled 18FDG powder in patients with chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Yanai, M.; Sasaki, H.; Hatazawa, J.; Ojima, F.; Itoh, M.; Ido, T.

    1998-01-01

    As freon is limited in its use as a generator for aerosol inhalation, powder particles are used as an alternative for inhalation therapy. The pulmonary deposition and clearance of inhaled powder particles was studied by positron emission tomography (PET) in ten patients with chronic obstructive pulmonary disease (COPD) and in five normal controls. The powder, 5 μm in mean diameter, was water soluble and labelled with 2-deoxy-2[ 18 F]-fluoro-D-glucose ( 18 FDG). Powder inhalation was done with single deep inspiration from residual volume to total lung capacity. The initial deposition ratio in the right or left lung field to total inhaled dose, measured by an anteroposterior rectilinear scan, did not differ between normal and COPD patients. Ratios of radioactivity detected within the central and peripheral regions (the central to peripheral ratio) measured by the PET scan was not significantly different between COPD patients (4.8±2.6, mean±SD) and normals (2.6±0.8, mean±SD). However, the regional powder deposition in peripheral lung fields measured by the PET scan was significantly more uneven in COPD patients than in normal patients. The clearance rate of 18 FDG, defined as the retention ratio of 18 FDG activity to the initially deposited 18 FDG at 60 and 120 min after inhalation, in the trachea, large bronchi or peripheral lung fields measured by tomographic scan showed a wider variation in COPD patients than in normals. To conclude, inhaled powder tended to be deposited more centrally and was distributed more unevenly in the peripheral lung in chronic obstructive pulmonary disease patients than in normals. This could be a limitation of powder inhalation used for therapy in chronic obstructive pulmonary disease patients. (au)

  3. Inhaled plutonium nitrate in dogs

    International Nuclear Information System (INIS)

    Dagle, G.E.

    1987-01-01

    The major objective of this project is to determine dose-effect relationships of inhaled plutonium nitrate in dogs to aid in predicting health effects of accidental exposure in man. For lifespan dose-effect studies, beagle dogs were given a single inhalation exposure to 239 Pu(NO 3 ) 4 , in 1976 and 1977. The earliest biological effect was on the hematopoietic system; lymphopenia and neutropenia occurred at the two highest dose levels. They have also observed radiation pneumonitis, lung cancer, and bone cancer at the three highest dose levels. 1 figure, 3 tables

  4. Inhaled plutonium nitrate in dogs

    International Nuclear Information System (INIS)

    Dagle, G.E.

    1986-01-01

    The major objective of this project is to determine dose-effect relationships of inhaled plutonium nitrate in dogs to aid in predicting health effects of accidental exposure in man. For lifespan dose-effect studies, beagle dogs were given a single inhalation exposure to 239 Pu(NO 3 ) 4 , in 1976 and 1977. The earliest biological effect was on the hematopoietic system; lymphopenia and neutropenia occurred at the two highest dose levels. The authors have also observed radiation pneumonitis, lung cancer, and bone cancer at the three highest dose levels. 1 figure, 4 tables

  5. Inhaled plutonium nitrate in dogs

    International Nuclear Information System (INIS)

    Dagle, G.E.

    1982-01-01

    The major objective of this project is to determine dose-effect relationships of inhaled plutonium nitrate in dogs to aid in the prediction of health effects of accidental exposure in man. For lifespan dose-effect studies, beagle dogs were given a single inhalation exposure to 239 Pu(NO 3 ) 4 , in 1976 and 1977. The earliest biological effect was on the hematopoietic system; as described in previous Annual Reports, lymphopenia and neutropenia occurred at the two highest dose levels. Radiation pneumonitis, lung cancer, and bone cancer have been observed at the highest dose levels

  6. Lung epithelial permeability and inhaled furosemide. Added dimensions in asthmatics

    International Nuclear Information System (INIS)

    Bhure, U.N.; Bhure, S.U.; Bhatt, B.M.; Mistry, S.; Pednekar, S.J.; Chari, V.V.; Desai, S.A.; Joshi, J.M.; Paidhungat, A.J.

    2009-01-01

    Lung clearance rates of inhaled 99m Tc-diethylene-triamine-pentaacetic acid (DTPA) aerosols constitute a sensitive index to evaluate the permeability changes characteristic of airway epithelial damage. It was thought that edema of the airway wall which is reported in asthma could be relieved with a diuretic like furosemide, helping to relieve the symptoms. We intended to study the effect of inhaled furosemide on lung epithelial permeability in asthmatics and smokers with the help of 99m Tc-DTPA lung clearance test (LCT). The study included three groups (n=15), viz. normal healthy controls, asymptomatic chronic smokers, and chronic persistent asthmatics. Each subject underwent the LCT twice, baseline and post-furosemide (Lasix) study, within a week's interval. The post-furosemide study was carried out 15 min after inhalation of 10 mg of lasix. Lung epithelial permeability was determined in terms of clearance half-life (T 1/2 ). The baseline mean T 1/2 values for controls, smokers, and asthmatics were 50.95±16.58, 20.81±5.47, 24.06±6.19 min, respectively. Post-lasix T 1/2 values were 50.83±15.84, 20.70±5.65, 41.27±15.07 min, respectively. There was a significant difference (P<0.001) in baseline and post-lasix clearance values in asthmatics only. Baseline lung epithelial permeability was altered in smokers and asthmatics compared to the controls. Furosemide was effective only in asthmatics in reverting the permeability almost back to the normal range. Inhaled furosemide was effective even in moderate and severe asthmatics. Furosemide has multiple mechanisms of action. It possibly acts at bronchial level in view of the pathology in asthmatics lying in the airways. (author)

  7. Clinical effectiveness of the Respimat® inhaler device in managing chronic obstructive pulmonary disease: evidence when compared with other handheld inhaler devices

    Directory of Open Access Journals (Sweden)

    et al

    2011-02-01

    only outcome for which data were available for meta-analysis was exacerbations, which were not significantly different (RR 1.20: P = 0.12. In addition, five trials with 2136 patients showed that there was no difference in risk of exacerbations or nasopharyngitis when Respimat was compared with all other handheld inhaler devices (RR 1.18: P = 0.13 and RR 1.33: P = 0.19, respectively. None of the clinical outcome measures reported was significantly different when the same, higher, or lower doses of medication were used in the inhaler devices being compared. Unfortunately, none of the included trials reported mortality as an outcome measure.Conclusions: Evidence from high-quality trials published to date suggests that the Respimat inhaler does not provide any additional clinical benefit to that provided by other inhaler devices in the management of COPD. Although in vitro studies have reported differences between the Respimat inhaler device and other handheld devices, we found no difference in any clinical outcome measures, including lung function and adverse events. Although recent reports have highlighted concerns of increased mortality with the Respimat inhaler device, none of the included trials reported mortality as an outcome. Only a small number of trials reported data that could be used in this systematic review, and a limited number of studies have been published that compare Respimat with other inhaler devices using the same drug and strength. Therefore, further trials comparing Respimat with other handheld inhaler devices using the same drug and dose are required before firm conclusions can be drawn. The concern with increased mortality with Respimat use should be investigated urgently.Keywords: Respimat, aerosol cloud, handheld inhaler devices, COPD

  8. Know How to Use Your Asthma Inhaler

    Medline Plus

    Full Text Available ... for Control Triggers Indoors In the Workplace Outdoors Management Asthma Action Plan Flu Shots Inhalers Data, Statistics, ... How to Use Your Asthma Inhaler Recommend on Facebook Tweet Share Compartir You can control your asthma ...

  9. Vectors for Inhaled Gene Therapy in Lung Cancer. Application for Nano Oncology and Safety of Bio Nanotechnology

    Science.gov (United States)

    Zarogouldis, Paul; Karamanos, Nikos K.; Porpodis, Konstantinos; Domvri, Kalliopi; Huang, Haidong; Hohenforst-Schimdt, Wolfgang; Goldberg, Eugene P.; Zarogoulidis, Konstantinos

    2012-01-01

    Novel aerosol therapeutic modalities have been investigated for lung cancer. Inhaled gene therapy has presented safety and effectiveness previously in cystic fibrosis. However, safety concerns have been raised regarding the safety of non-viral vectors for inhaled gene therapy in lung cancer, and therefore small steps have been made towards this multifunctional treatment modality. During the last decade, numerous new nanocomplexes have been created and investigated as a safe gene delivery nano-vehicle. These formulations are multifunctional; they can be used as either local therapy or carrier for an effective inhaled gene therapy for lung cancer. Herein, we present current and future perspectives of nanocomplexes for inhaled gene therapy treatment in lung cancer. PMID:23109824

  10. Effects of inspiratory resistance, inhaled beta-agonists and histamine on canine tracheal blood flow

    International Nuclear Information System (INIS)

    Kelly, W.T.; Baile, E.M.; Brancatisano, A.; Pare, P.D.; Engel, L.A.

    1992-01-01

    Tracheobronchial blood flow is potentially important in asthma as it could either influence the clearance of mediators form the airways, thus affecting the duration and severity of bronchoispasm, or enhance oedema formation with a resultant increase in airflow obstruction. In anaesthetized dogs, spontaneously breathing via a tracheostomy, we investigated the effects of three interventions which are relevant to acute asthma attacks and could potentially influence blood flow and its distribution to the mucosa and remaining tissues of the trachea: 1) increased negative intrathoracic pressure swings (-25±1 cmH 2 O) induced by an inspiratory resistance; 2) variable inhaled doses of a beta-adrenoceptor-agonist (terbutaline); and 3) aerosolized histamine sufficient to produce a threefold increase in pulmonary resistance. Microspheres labelled with different radioisotopes were used to measure blood flow. Resistive breathing did not influence tracheobronchial blood flow. Following a large dose of terbutaline, mucosal blood flow (Qmb) increased by 50%. After inhaled histamine, Qmb reached 265% of the baseline value. We conclude that, whereas increased negative pressure swings do not influence tracheobronchial blood flow or its distribution, inhalation of aerosolized terbutaline, corresponding to a conventionally nebulized dose, increases mucosal blood flow. Our results also confirm that inhaled histamine, in a dose sufficient to produce moderate bronchoconstriction, increases tracheal mucosal blood flow in the area of deposition. (au)

  11. Effects of inspiratory resistance, inhaled beta-agonists and histamine on canine tracheal blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, W.T.; Baile, E.M.; Brancatisano, A.; Pare, P.D.; Engel, L.A. (Dept. of Respiratory Medicine, Westmead Hospital, Westmead, NSW (Australia))

    1992-01-01

    Tracheobronchial blood flow is potentially important in asthma as it could either influence the clearance of mediators form the airways, thus affecting the duration and severity of bronchoispasm, or enhance oedema formation with a resultant increase in airflow obstruction. In anaesthetized dogs, spontaneously breathing via a tracheostomy, we investigated the effects of three interventions which are relevant to acute asthma attacks and could potentially influence blood flow and its distribution to the mucosa and remaining tissues of the trachea: (1) increased negative intrathoracic pressure swings (-25[+-]1 cmH[sub 2]O) induced by an inspiratory resistance; (2) variable inhaled doses of a beta-adrenoceptor-agonist (terbutaline); and (3) aerosolized histamine sufficient to produce a threefold increase in pulmonary resistance. Microspheres labelled with different radioisotopes were used to measure blood flow. Resistive breathing did not influence tracheobronchial blood flow. Following a large dose of terbutaline, mucosal blood flow (Qmb) increased by 50%. After inhaled histamine, Qmb reached 265% of the baseline value. We conclude that, whereas increased negative pressure swings do not influence tracheobronchial blood flow or its distribution, inhalation of aerosolized terbutaline, corresponding to a conventionally nebulized dose, increases mucosal blood flow. Our results also confirm that inhaled histamine, in a dose sufficient to produce moderate bronchoconstriction, increases tracheal mucosal blood flow in the area of deposition. (au).

  12. Characterization of atmospheric aerosol in Buenos Aires, Argentina

    International Nuclear Information System (INIS)

    Jasan, R.C.; Pla, R.R.; Invernizzi, R.; Dos Santos, M.

    2009-01-01

    PM10 and PM2.5 samples were taken using a Gent sampler to characterize the atmospheric aerosol of Buenos Aires metropolitan area. A total of 114 samples were collected from October 2005 to October 2006 at one urban site, every third day, for 24 h. Samples were analyzed by neutron activation, and black carbon and mass concentration were determined. In both fractions, elemental and gravimetric mass concentrations were compared with historical data. Enrichment factors, backward trajectories and factor analysis were calculated. The attribution of pollution sources is discussed. (author)

  13. A Bayesian Sampler for Optimization of Protein Domain Hierarchies

    Science.gov (United States)

    2014-01-01

    Abstract The process of identifying and modeling functionally divergent subgroups for a specific protein domain class and arranging these subgroups hierarchically has, thus far, largely been done via manual curation. How to accomplish this automatically and optimally is an unsolved statistical and algorithmic problem that is addressed here via Markov chain Monte Carlo sampling. Taking as input a (typically very large) multiple-sequence alignment, the sampler creates and optimizes a hierarchy by adding and deleting leaf nodes, by moving nodes and subtrees up and down the hierarchy, by inserting or deleting internal nodes, and by redefining the sequences and conserved patterns associated with each node. All such operations are based on a probability distribution that models the conserved and divergent patterns defining each subgroup. When we view these patterns as sequence determinants of protein function, each node or subtree in such a hierarchy corresponds to a subgroup of sequences with similar biological properties. The sampler can be applied either de novo or to an existing hierarchy. When applied to 60 protein domains from multiple starting points in this way, it converged on similar solutions with nearly identical log-likelihood ratio scores, suggesting that it typically finds the optimal peak in the posterior probability distribution. Similarities and differences between independently generated, nearly optimal hierarchies for a given domain help distinguish robust from statistically uncertain features. Thus, a future application of the sampler is to provide confidence measures for various features of a domain hierarchy. PMID:24494927

  14. Partitioning of organochlorine pesticides from water to polyethylene passive samplers

    International Nuclear Information System (INIS)

    Hale, Sarah E.; Martin, Timothy J.; Goss, Kai-Uwe; Arp, Hans Peter H.; Werner, David

    2010-01-01

    The mass transfer rates and equilibrium partitioning behaviour of 14 diverse organochlorine pesticides (OCP) between water and polyethylene (PE) passive samplers, cut from custom made PE sheets and commercial polyethylene plastic bags, were quantified. Overall mass transfer coefficients, k O , estimated PE membrane diffusion coefficients, D PE , and PE-water partitioning coefficients, K PE-water, are reported. In addition, the partitioning of three polycyclic aromatic hydrocarbons (PAHs) from water to PE is quantified and compared with literature values. K PE-water values agreed mostly within a factor of two for both passive samplers and also with literature values for the reference PAHs. As PE is expected to exhibit similar sorption behaviour to long-chain alkanes, PE-water partitioning coefficients were compared to hexadecane-water partitioning coefficients estimated with the SPARC online calculator, COSMOtherm and a polyparameter linear free energy relationship based on the Abraham approach. The best correlation for all compounds tested was with COSMOtherm estimated hexadecane-water partitioning coefficients. - The partitioning of organochlorine pesticides between single phase polyethylene passive samplers and water is quantified.

  15. A carbon monoxide passive sampler: Research and development needs

    Energy Technology Data Exchange (ETDEWEB)

    Traynor, G.W.; Apte, M.G.; Diamond, R.C.; Woods, A.L.

    1991-11-01

    In rare instances, carbon monoxide (CO) levels in houses can reach dangerously high concentrations, causing adverse health effects ranging from mild headaches to, under extreme conditions, death. Hundreds of fatal accidental carbon monoxide poisonings occur each year primarily due to the indoor operation of motor vehicles, the indoor use of charcoal for cooking, the operation of malfunctioning vented and unvented combustion appliances, and the misuse combustion appliances. Because there is a lack of simple, inexpensive, and accurate field sampling instrumentation, it is difficult for gas utilities and researchers to conduct field research studies designed to quantify the concentrations of CO in residences. Determining the concentration of CO in residences is the first step towards identifying the high risk appliances and high-CO environments which pose health risks. Thus, there exists an urgent need to develop and field-validate a CO-quantifying technique suitable for affordable field research. A CO passive sampler, if developed, could fulfill these requirements. Existing CO monitoring techniques are discussed as well as three potential CO-detection methods for use in a CO passive sampler. Laboratory and field research needed for the development and validation of an effective and cost-efficient CO passive sampler are also discussed.

  16. Performances of an atmospheric tritium sampler and its application

    International Nuclear Information System (INIS)

    Inoue, Yoshikazu; Kahn, B.; Carter, M.W.

    1983-01-01

    A sampling system for atmospheric tritium in the form of water vapor, hydrogen and hydrocarbons was designed and built. The air was passed first through molecular sieve which adsorbed water vapor, then over palladium catalyst which oxidized hydrogen and adsorbed resulting water in situ, and finally over hot Hopcalite catalyst, which oxidized hydrocarbons and the resulting water was adsorbed on a following molecular sieve column. Three water samples were extracted from adsorbers and their tritium contents were measured by liquid scintillation counting. Performances of this sampler were examined for retrieval of tritiated water from molecular sieve, oxidation of hydrogen on palladium catalyst and oxidation of methane on Hopcalite. The portable sampler was applied to analyze tritium in a duct air of a heavy water moderated research reactor. More than 99% of total tritium was in vapor form. Trace amounts of tritiated hydrogen and hydrocarbon were also detected. This tritium sampler is applicable to detect all of atmospheric tritium as high as ten times of ambient levels. (author)

  17. Design of a device for simultaneous particle size and electrostatic charge measurement of inhalation drugs.

    Science.gov (United States)

    Zhu, Kewu; Ng, Wai Kiong; Shen, Shoucang; Tan, Reginald B H; Heng, Paul W S

    2008-11-01

    To develop a device for simultaneous measurement of particle aerodynamic diameter and electrostatic charge of inhalation aerosols. An integrated system consisting of an add-on charge measurement device and a liquid impinger was developed to simultaneously determine particle aerodynamic diameter and electrostatic charge. The accuracy in charge measurement and fine particle fraction characterization of the new system was evaluated. The integrated system was then applied to analyze the electrostatic charges of a DPI formulation composed of salbutamol sulphate-Inhalac 230 dispersed using a Rotahaler. The charge measurement accuracy was comparable with the Faraday cage method, and incorporation of the charge measurement module had no effect on the performance of the liquid impinger. Salbutamol sulphate carried negative charges while the net charge of Inhalac 230 and un-dispersed salbutamol sulphate was found to be positive after being aerosolized from the inhaler. The instantaneous current signal was strong with small noise to signal ratio, and good reproducibility of charge to mass ratio was obtained for the DPI system investigated. A system for simultaneously measuring particle aerodynamic diameter and aerosol electrostatic charges has been developed, and the system provides a non-intrusive and reliable electrostatic charge characterization method for inhalation dosage forms.

  18. Characterization of biomass burning aerosols from forest fire in Indonesia

    Science.gov (United States)

    Fujii, Y.; Iriana, W.; Okumura, M.; Lestari, P.; Tohno, S.; Akira, M.; Okuda, T.

    2012-12-01

    Biomass burning (forest fire, wild fire) is a major source of pollutants, generating an estimate of 104 Tg per year of aerosol particles worldwide. These particles have adverse human health effects and can affect the radiation budget and climate directly and indirectly. Eighty percent of biomass burning aerosols are generated in the tropics and about thirty percent of them originate in the tropical regions of Asia (Andreae, 1991). Several recent studies have reported on the organic compositions of biomass burning aerosols in the tropical regions of South America and Africa, however, there is little data about forest fire aerosols in the tropical regions of Asia. It is important to characterize biomass burning aerosols in the tropical regions of Asia because the aerosol properties vary between fires depending on type and moisture of wood, combustion phase, wind conditions, and several other variables (Reid et al., 2005). We have characterized PM2.5 fractions of biomass burning aerosols emitted from forest fire in Indonesia. During the dry season in 2012, PM2.5 aerosols from several forest fires occurring in Riau, Sumatra, Indonesia were collected on quartz and teflon filters with two mini-volume samplers. Background aerosols in forest were sampled during transition period of rainy season to dry season (baseline period). Samples were analyzed with several analytical instruments. The carbonaceous content (organic and elemental carbon, OC and EC) of the aerosols was analyzed by a thermal optical reflectance technique using IMPROVE protocol. The metal, inorganic ion and organic components of the aerosols were analyzed by X-ray Fluorescence (XRF), ion chromatography and gas chromatography-mass spectrometry, respectively. There was a great difference of chemical composition between forest fire and non-forest fire samples. Smoke aerosols for forest fires events were composed of ~ 45 % OC and ~ 2.5 % EC. On the other hand, background aerosols for baseline periods were

  19. Self-charging of 198Au-labeled monodisperse gold aerosols studied with a miniature electrical mobility spectrometer

    International Nuclear Information System (INIS)

    Yeh, H.C.; Newton, G.J.; Raabe, O.G.; Boor, D.R.

    1976-01-01

    Knowledge of the electrostatic character of an aerosol may be essential in assessing its potential inhalation hazard. In inhalation studies with radioactive aerosols, the aerosol charge state may change in the course of transport due to the emission of α, β or γ radiations. This paper describes an experimental study of the self-charging of 198 Au-labeled aerosols of monodisperse gold spheres by β emission. A miniature aerosol electrical mobility spectrometer, suitable for use in inhalation studies with radioactive aerosols, was developed and used in this study. This device is relatively inexpensive, easy to manufacture and its contamination by radioactive material has been minimized. Using polystyrene latex spheres, ranging in diameter from 0.176 to 1.18 μm, the spectrometer was calibrated with flow rates ranging from 400 to 4800 ml/min. Experiments with two sizes of 198 Au-labeled monodisperse gold aerosols were performed. Results indicate that the radioactivity of an aerosol can cause self-charging and affect the charge distribution. (author)

  20. Electrostatic