WorldWideScience

Sample records for infrarenal aortic grafting

  1. Accidental Coverage of Both Renal Arteries during Infrarenal Aortic Stent-Graft Implantation: Cause and Treatment

    Directory of Open Access Journals (Sweden)

    Umberto Marcello Bracale

    2014-01-01

    Full Text Available The purpose of this paper is to report a salvage maneuver for accidental coverage of both renal arteries during endovascular aneurysm repair (EVAR of an infrarenal abdominal aortic aneurysm (AAA. A 72-year-old female with a 6 cm infrarenal abdominal aortic aneurysm was treated by endovascular means with a standard bifurcated graft. Upon completing an angiogram, both renal arteries were found to be accidentally occluded. Through a left percutaneous brachial approach, the right renal artery was catheterized and a chimney stent was deployed; however this was not possible for the left renal artery. A retroperitoneal surgical approach was therefore carried out with a retrograde chimney stent implanted to restore blood flow. After three months, both renal arteries were patent and renal function was not different from the baseline. Both endovascular with percutaneous access via the brachial artery and open retroperitoneal approaches with retrograde catheterization are feasible rescue techniques to recanalize the accidentally occluded renal arteries during EVAR.

  2. Tube Stent-Grafts for Infrarenal Aortic Aneurysm: A Matched-Paired Analysis Based on EUROSTAR Data

    International Nuclear Information System (INIS)

    Ruppert, Volker; Leurs, Lina J.; Hobo, Roel; Buth, Jacob; Rieger, Johannes; Umscheid, Thomas

    2007-01-01

    Objective. Tube stent-grafts for treatment of infrarenal aortic aneurysms (AAAs) are a nearly forgotten concept. For focal aortic pathologies tube stent-grafts may be a treatment option. We have performed a retrospective matched-paired analysis of the EUROSTAR registry regarding the outcome of tube vs. bifurcated stent-grafts for AAA. Tapered aortomonoiliac stent-grafts were not the objective of this study. Materials and methods. From July 1997 to June 2006, 7581 patients who underwent an endovascular AAA repair were entered in the EUROSTAR registry by 164 centers. One hundred fifty-three patients were treated with tube stent-grafts. For each of these 153 patients we selected one patient from a bifurcated stent-graft group (BGG-original, 7428 patients) matched according to gender, ASA, age, AAA diameter, and type of anesthesia. Differences in preoperative details between the two study groups were analyzed using chi-square test for discrete variables and Wilcoxon rank-sum test for continuous variables. Multivariate logistic regression analysis was performed on early complications. Midterm outcomes (>30 days) were analyzed by Kaplan-Meier and multivariate Cox proportional hazard model. Results. The duration of the procedure was shorter in the tube stent-graft group (TGG; 102.3 ± 52.2) than in BGG (128.3 ± 55.0; p 0.0002). Type II endoleak was less frequent in TGG (4.0%; mean follow-up, 23.12 ± 23.9 months) than in BGG (14.3%; mean follow-up, 20.77 ± 20.0 months; p = 0.0394). Type I endoleaks and migration were distributed equally, without significant differences between the groups. Combined 30-day and late mortality was higher for TGG (p = 0.0346) and was obviously not aneurysm related. Conclusions. We conclude that after selection of patients, tube stent-grafts for infrarenal aortic repair can be performed with great safety regarding endoleaks and migration. The combined higher 30-day mortality and non-aneurysm-related mortality during follow-up were mainly

  3. Contemporary management of isolated chronic infrarenal abdominal aortic dissections.

    Science.gov (United States)

    Faries, Christopher M; Tadros, Rami O; Lajos, Paul S; Vouyouka, Ageliki G; Faries, Peter L; Marin, Michael L

    2016-11-01

    mortality rate for endovascular intervention was 0%. The only open surgical repair performed was on a patient with a ruptured AAA, which the patient did not survive. Angioplasty with stent or stent graft placement was performed in four patients for the treatment of symptomatic arterial insufficiency resulting from aortic dissection. No patients experienced restenosis, and no reinterventions were performed. Isolated infrarenal aortic dissection is an uncommon vascular disease that is related to hypertension, hyperlipidemia, and atherosclerosis and may be associated with infrarenal AAA formation. The presence of dissection does not appear to increase the risk of complication or mortality for repair of concomitant aneurysm or for treatment of stenosis. Copyright © 2016. Published by Elsevier Inc.

  4. Infrarenal Abdominal Aortic Pseudoaneurysm: Is It a Real Emergency?

    Science.gov (United States)

    Massara, Mafalda; Prunella, Roberto; Gerardi, Pasquale; Lillo, Antonio; De Caridi, Giovanni; Serra, Raffaele; Notarstefano, Stefano; Impedovo, Giovanni

    2017-01-01

    Abdominal aortic pseudoaneurysm is a rare but life-threatening condition that occurs due to penetrating or blunt trauma. Clinical manifestations are variable, and the time interval from the initial trauma to diagnosis is variable. A prompt diagnosis and an aggressive management approach are required to avoid catastrophic complications. Possible treatment options are open surgical repair, endovascular repair, pseudoanerysmal sac thrombosis induction through direct thrombin injection, and coil embolization. Here, we present the case of a 75-year-old man affected by an infrarenal abdominal aortic pseudoaneurysm presenting with abdominal and lumbar pain for 3 days, who was successfully treated with an endograft. PMID:29515707

  5. Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It

    Directory of Open Access Journals (Sweden)

    Rui Machado

    Full Text Available Abstract Objective: The endovascular repair of aortic abdominal aneurysms exposes the patients and surgical team to ionizing radiation with risk of direct tissue damage and induction of gene mutation. This study aims to describe our standard of radiation exposure in endovascular aortic aneurysm repair and the factors that influence it. Methods: Retrospective analysis of a prospective database of patients with abdominal infra-renal aortic aneurysms submitted to endovascular repair. This study evaluated the radiation doses (dose area product (DAP, fluoroscopy durations and their relationships to the patients, aneurysms, and stent-graft characteristics. Results: This study included 127 patients with a mean age of 73 years. The mean DAP was 4.8 mGy.m2, and the fluoroscopy time was 21.8 minutes. Aortic bilateral iliac aneurysms, higher body mass index, aneurysms with diameters larger than 60 mm, necks with diameters larger than 28 mm, common iliac arteries with diameters larger than 20 mm, and neck angulations superior to 50 degrees were associated with an increased radiation dose. The number of anatomic risk factors present was associated with increased radiation exposure and fluoroscopy time, regardless of the anatomical risk factors. Conclusion: The radiation exposure during endovascular aortic aneurysm repair is significant (mean DAP 4.8 mGy.m2 with potential hazards to the surgical team and the patients. The anatomical characteristics of the aneurysm, patient characteristics, and the procedure's technical difficulty were all related to increased radiation exposure during endovascular aortic aneurysm repair procedures. Approximately 40% of radiation exposure can be explained by body mass index, neck angulation, aneurysm diameter, neck diameter, and aneurysm type.

  6. Induction of continuous expanding infrarenal aortic aneurysms in a large porcine animal model

    DEFF Research Database (Denmark)

    Kloster, Brian Ozeraitis; Lund, Lars; Lindholt, Jes S.

    2015-01-01

    BackgroundA large animal model with a continuous expanding infrarenal aortic aneurysm gives access to a more realistic AAA model with anatomy and physiology similar to humans, and thus allows for new experimental research in the natural history and treatment options of the disease. Methods10 pigs...

  7. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    International Nuclear Information System (INIS)

    Steingruber, I.E.; Neuhauser, B.; Seiler, R.; Greiner, A.; Chemelli, A.; Kopf, H.; Walch, C.; Waldenberger, P.; Jaschke, W.; Czermak, B.

    2006-01-01

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions

  8. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Steingruber, I.E. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)]. E-mail: iris.steingruber@uibk.ac.at; Neuhauser, B. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Seiler, R. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Greiner, A. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Chemelli, A. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Kopf, H. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Walch, C. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Waldenberger, P. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Jaschke, W. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Czermak, B. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)

    2006-09-15

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions.

  9. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  10. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  11. Update: Complications and management of infrarenal EVAR

    International Nuclear Information System (INIS)

    Liaw, J.V.P.; Clark, M.; Gibbs, R.; Jenkins, M.; Cheshire, N.; Hamady, M.

    2009-01-01

    Endovascular aortic aneurysm repair (EVAR) is now an established technique for treating many patients with infrarenal abdominal aortic aneurysm. Familiarity with the complications associated with this technique and understanding treatment options are crucial for the lifelong performance of stent graft. This pictorial review article describes the currant role of different imaging modalities in surveillance and discusses the complications and its management strategies.

  12. Influence of atmospheric pressure on infrarenal abdominal aortic aneurysm rupture.

    Science.gov (United States)

    Robert, Nicolas; Frank, Michael; Avenin, Laure; Hemery, Francois; Becquemin, Jean Pierre

    2014-04-01

    Meteorologic conditions have a significant impact on the occurrence of cardiovascular events. Previous studies have shown that abdominal aortic aneurysm rupture (AAAR) may be associated with atmospheric pressure, with conflicting results. Therefore, we aimed to further investigate the nature of the correlation between atmospheric pressure variations and AAAR. Hospital admissions related to AAAR between 2005-2009 were assessed in 19 districts of metropolitan France and correlated with geographically and date-matched mean atmospheric pressures. In parallel and from 2005-2009, all fatal AAARs as reported by death certificates were assessed nationwide and correlated to local atmospheric pressures at the time of aortic rupture. Four hundred ninety-four hospital admissions related to AAAR and 6,358 deaths nationwide by AAAR were identified between 2005-2009. Both in-hospital ruptures and aneurysm-related mortality had seasonal variations, with peak/trough incidences in January and June, respectively. Atmospheric pressure peaks occurred during winter. Univariate analysis revealed a significant association (P atmospheric pressure values and AAAR. After multivariate analysis, mean maximum 1-month prerupture atmospheric pressure had a persistent correlation with both in-hospital relative risk (1.05 [95% confidence interval: 1.03-1.06]; P atmospheric pressure. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Spontaneous Retroperitoneal Hematoma Simulating Ruptured Infrarenal Aortic Aneurysm in a Patient with End-Stage Renal Disease

    Science.gov (United States)

    Li, JYY; Chan, YC; Qing, KX; Cheng, SW

    2014-01-01

    We reported a case of spontaneous retroperitoneal hematoma (SRH) simulating a ruptured infrarenal aortic aneurysm. A 72-year-old man with a history of infrarenal aortic aneurysm and end-stage renal disease on hemodialysis presented with malaise and nonspecific central abdominal pain and left loin discomfort. An emergency computed tomography scan showed a large retroperitoneal hematoma and clinical suspicion of ruptured infrarenal aortic aneurysm. However, the hematoma was discontinuous with the aneurysm sac and raised the clinical suspicion on dual pathology. The SRH was treated conservatively with transfusion of blood products, and the aneurysm was treated with nonemergency endovascular repair electively. This case demonstrates the importance of recognizing different clinical and radiological characteristics and be aware of dual pathology. PMID:28031651

  14. Aortic Stent-Graft Infection Following Septic Complications of a Kidney Stone

    International Nuclear Information System (INIS)

    Berg, H. Rogier van den; Leijdekkers, Vanessa J.; Vahl, Anco

    2006-01-01

    A 73-year-old man was treated because of a renal pelvis blowout of the left kidney for which he received a nephrostomy catheter without antibiotic prophylaxis. Almost a year previously this patient had undergone endovascular repair of a symptomatic infrarenal abdominal aorta aneurysm. Four weeks after the diagnosis and treatment of the ruptured renal pelvis, a new computed tomography scan and ultrasound-guided fine needle aspiration confirmed the diagnosis of infected aortic stent-graft. An extra-anatomic axillo-uniiliac bypass and graft excision was performed. Two weeks after discharge the patient returned to the hospital with an occlusion of his left renal artery and died of renal failure. This is the first time an infected aortic stent-graft after a renal pelvis blowout has been reported. Although infections of aortic stent-grafts occur rarely, one should be aware of the possibility in aortic stent-graft patients undergoing abdominal procedures without antibiotic prophylaxis

  15. Induction of continuous expanding infrarenal aortic aneurysms in a large porcine animal model

    DEFF Research Database (Denmark)

    Kloster, Brian Ozeraitis; Lund, Lars; Lindholt, Jes S.

    2015-01-01

    frequent complication was a neurological deficit in the lower limbs. ConclusionIn pigs it’s possible to induce continuous expanding AAA’s based upon proteolytic degradation and pathological flow, resembling the real life dynamics of human aneurysms. Because the lumbars are preserved, it’s also a potential......BackgroundA large animal model with a continuous expanding infrarenal aortic aneurysm gives access to a more realistic AAA model with anatomy and physiology similar to humans, and thus allows for new experimental research in the natural history and treatment options of the disease. Methods10 pigs......, hereafter the pigs were euthanized for inspection and AAA wall sampling for histological analysis. ResultsIn group A, all pigs developed continuous expanding AAA’s with a mean increase in AP-diameter to 16.26 ± 0.93 mm equivalent to a 57% increase. In group B the AP-diameters increased to 11.33 ± 0.13 mm...

  16. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open

  17. Physiologic Responses to Infrarenal Aortic Cross-Clamping during Laparoscopic or Conventional Vascular Surgery in Experimental Animal Model: Comparative Study

    Directory of Open Access Journals (Sweden)

    María F. Martín-Cancho

    2008-01-01

    Full Text Available The aim of this study was to compare the hemodynamic and ventilatory effects of prolonged infrarenal aortic cross-clamping in pigs undergoing either laparotomy or laparoscopy. 18 pigs were used for this study. Infrarenal aortic crossclamping was performed for 60 minutes in groups I (laparotomy, n=6 and II (laparoscopy, n=6. Group III (laparoscopy, n=6 underwent a 120-minute long pneumoperitoneum in absence of aortic clamping (sham group. Ventilatory and hemodynamic parameters and renal function were serially determined in all groups. A significant decrease in pH and significant increase in PaCO2 were observed in group II, whereas no changes in these parameters were seen in group I and III. All variables returned to values similar to baseline in groups I and II 60 minutes after declamping. A significant increase in renal resistive index was evidenced during laparoscopy, with significantly higher values seen in Group II. Thus a synergic effect of pneumoperitoneum and aortic cross-clamping was seen in this study. These two factors together cause decreased renal perfusion and acidosis, thus negatively affecting the patient's general state during this type of surgery.

  18. Graft infections after surgical aortic reconstructions

    OpenAIRE

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open surgical reconstructions as first line of treatment for aorto-iliac diseases. Nowadays, open reconstructions are primarily reserved for patients unsuitable for endovascular reconstructions or for redo ...

  19. The Relationship Between Serum Interleukin-1α and Asymptomatic Infrarenal Abdominal Aortic Aneurysm Size, Morphology, and Growth Rates.

    Science.gov (United States)

    Ahmad, Mehtab; Kuravi, Sahithi; Hodson, James; Rainger, G Ed; Nash, Gerard B; Vohra, Rajiv K; Bradbury, Andrew W

    2018-02-16

    In a pilot study, a relationship between abdominal aortic aneurysm (AAA) diameter and serum interleukin (IL)-1α levels was reported, and that endothelial cell (EC) activation in vitro in response to serum from patients with AAA was blocked by anti-IL-1α antibodies. The aim of the present study was to further investigate the relationship between serum IL-1α and asymptomatic infrarenal AAA size, morphology, and growth rates. Serum IL-1α was measured using enzyme linked immunosorbent assay in 101 patients with asymptomatic, infrarenal AAA and related to aneurysm size, morphology, and growth rates. IL-1α was measured in 101 patients. There was no statistically significant difference in mean age between men and women. IL-1α was detectable in 62.4% of patients; median IL-1α titre was 3.26 pg/mL. There was no statistically significant relationship between IL-1α and maximum AAA antero-posterior diameter as measured by ultrasound (p = .649), AAA morphology (aortic length [p = .394], sac [p = .369], and thrombus volume [p = .629]) as measured on computed tomography, absolute increase in AAA diameter (p = .214), or AAA growth rate (p = .230). IL-1α is detectable in the majority of patients with infrarenal AAA, but the cause and clinical significance of this novel observation remains unknown. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Aortic reconstruction with bovine pericardial grafts

    Directory of Open Access Journals (Sweden)

    Silveira Lindemberg Mota

    2003-01-01

    Full Text Available INTRODUCTION: Glutaraldehyde-treated crimped bovine pericardial grafts are currently used in aortic graft surgery. These conduits have become good options for these operations, available in different sizes and shapes and at a low cost. OBJECTIVE:To evaluate the results obtained with bovine pericardial grafts for aortic reconstruction, specially concerning late complications. METHOD: Between January 1995 and January 2002, 57 patients underwent different types of aortic reconstruction operations using bovine pericardial grafts. A total of 29 (50.8% were operated on an urgent basis (mostly acute Stanford A dissection and 28 electively. Thoracotomy was performed in three patients for descending aortic replacement (two patients and aortoplasty with a patch in one. All remaining 54 underwent sternotomy, cardiopulmonary bypass and aortic resection. Deep hypothermia and total circulatory arrest was used in acute dissections and arch operations. RESULTS: Hospital mortality was 17.5%. Follow-up was 24.09 months (18.5 to 29.8 months confidence interval and complication-free actuarial survival curve was 92.3% (standard deviation ± 10.6. Two patients lately developed thoracoabdominal aneurysms following previous DeBakey II dissection and one died from endocarditis. One "patch" aortoplasty patient developed local descending aortic pseudoaneurysm 42 months after surgery. All other patients are asymptomatic and currently clinically evaluated with echocardiography and CT scans, showing no complications. CONCLUSION: Use of bovine pericardial grafts in aortic reconstruction surgery is adequate and safe, with few complications related to the conduits.

  1. Aortic Graft Infection Secondary to Iatrogenic Transcolonic Graft Malposition.

    Science.gov (United States)

    Blank, Jacqueline J; Rothstein, Abby E; Lee, Cheong Jun; Malinowski, Michael J; Lewis, Brian D; Ridolfi, Timothy J; Otterson, Mary F

    2018-01-01

    Aortic graft infections are a rare but devastating complication of aortic revascularization. Often infections occur due to contamination at the time of surgery. Iatrogenic misplacement of the limbs of an aortobifemoral graft is exceedingly rare, and principles of evaluation and treatment are not well defined. We report 2 cases of aortobifemoral bypass graft malposition through the colon. Case 1 is a 54-year-old male who underwent aortobifemoral bypass grafting for acute limb ischemia. He had previously undergone a partial sigmoid colectomy for diverticulitis. Approximately 6 months after vascular surgery, he presented with an occult graft infection. Preoperative imaging and intraoperative findings were consistent with graft placement through the sigmoid colon. Case 2 is a 60-year-old male who underwent aortobifemoral bypass grafting due to a nonhealing wound after toe amputation. His postoperative course was complicated by pneumonia, bacteremia thought to be secondary to the pneumonia, general malaise, and persistent fevers. Approximately 10 weeks after the vascular surgery, he presented with imaging and intraoperative findings of graft malposition through the cecum. Aortic graft infection is usually caused by surgical contamination and presents as an indolent infection. Case 1 presented as such; Case 2 presented more acutely. Both grafts were iatrogenically misplaced through the colon at the index operation. The patients underwent extra-anatomic bypass and graft explantation and subsequently recovered.

  2. Primary Infrarenal Aortic Stenting With or Without Iliac Stenting for Isolated and Aortoiliac Stenoses: Single-Centre Experience With Long-Term Follow-Up

    Energy Technology Data Exchange (ETDEWEB)

    Tapping, C. R.; Ahmed, M.; Scott, P. M.; Lakshminarayan, R.; Robinson, G. J.; Ettles, D. F.; Shrivastava, V., E-mail: vivek.shrivastava@hey.nhs.uk [Hull Royal Infirmary, Hull and East Yorkshire Hospitals NHS Trust, Department of Radiology (United Kingdom)

    2013-02-15

    The purpose of this study was to evaluate the technical success, complications, long-term clinical outcome, and patency after primary infrarenal aortic stenting for aortic and aortoiliac stenosis. Between January 1999 and January 2006, 22 consecutive patients underwent endovascular treatment because of infrarenal aortic stenosis with and without common iliac stenosis (10 men; mean age 64 {+-} 14 years). Eleven (11 of 22) patients had an isolated aortic stenosis, whereas 11 of 22 had aortic stenosis that extended into the common iliac arteries (CIAs). Thirteen patients were Rutherford classification type 3, and 9 patients were type 4. Statistical analysis included paired Student t test and Kaplan-Meier life table analysis; p < 0.05 was considered significant. Technical and initial clinical success was achieved in all patients. There were three (14 %) procedure-related complications, which included two access-point pseudoaneurysms and one non-flow-limiting left external iliac dissection. Patients were followed-up for a mean period of 88 months (range 60-132). Mean preprocedure ankle brachial pressure indexes (ABPI) were 0.60 {+-} -0.15 (right) and 0.61 {+-} -0.16 (left). After the procedure they were 0.86 {+-} -0.07 (right) and 0.90 {+-} -0.09 (left). The increase in ABPI was significant (p < 0.05), and this continued throughout follow-up. Four (18 %) patients had recurrence of symptoms during follow-up. These occurred at 36, 48, 48, and 50 months after the original procedure. All four patients were successfully treated with repeat angioplasty procedures. There was a significant difference in primary patency between isolated aortic stenosis (100 %) and aortoiliac stenosis (60 %) (p = 0.031). Cumulative follow-up was 1920 months yielding a reintervention rate of 0.025/events/year. Primary stenting of infrarenal stenosis is safe and successful with a low reintervention rate. It should be considered as first-line treatment for patients with infrarenal aortic stenotic

  3. Endo-luminal grafting for treatment of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Fu Weiguo; Wang Yuqi; Chen Fuzhen; Ye Jianrong; Wang Jianhua; Yan Zhiping; Cheng Jiemin

    2000-01-01

    Objective: To evaluate the preliminary clinical results of endovascular procedures for abdominal aortic aneurysms (AAA) in a prospective study. Methods: Six patients (average age 70 years, range 56 to 78) with infrarenal AAA were enrolled in Shanghai Zhongshan hospital from February 1998 to February 1999. Computed tomography and angiography were done in every patient for measurement of the length, diameter, and angulation of the proximal and distal AAA necks, aneurysm sac, and common and external iliac arteries. The average diameter of the aneurysm was 6.3 cm (range 4.6 cm to 8.0 cm). The mean proximal neck diameter was 2.0 cm (range 1.8 cm to 2.2 cm) and proximal neck length was 3.0 cm (range 2.5 cm to 3.5 cm). All patients were treated with the endo-luminal grafting for exclusion of AAA. Results: Two tubular and 4 bifurcated endo-grafts were used. All endo-graft procedures were completed successfully. One patient died of renal failure 72 hours after the procedure because of the prolonged operative time and excessive contrast medium. Aortography after the procedure showed the AAA were excluded by endo-graft and no endo-leak in the proximal or distal connections was detected. The patients could take meal and were ambulatory on the first and second postoperative day, respectively. Clinical success (aneurysm exclusion with no death or endo-leak) at 30 days was 83.3%. In the 24 months follow-up in 5 cases, no migration, endo-leak, and increasing aneurysm size were detected with spiral CT or color Duplex ultrasound. Conclusion: Based on initial results and a short term mean follow-up period of 24 months, the endovascular treatment of AAA with stent-graft system is feasible and safe. Further study will be required to observe the long term result in the exclusion of AAA

  4. Non- invasive in vivo analysis of a murine aortic graft using high resolution ultrasound microimaging

    International Nuclear Information System (INIS)

    Rowinska, Zuzanna; Zander, Simone; Zernecke, Alma; Jacobs, Michael; Langer, Stephan; Weber, Christian; Merx, Marc W.; Koeppel, Thomas A.

    2012-01-01

    Introduction: As yet, murine aortic grafts have merely been monitored histopathologically. The aim of our study was to examine how these grafts can be monitored in vivo and non-invasively by using high-resolution ultrasound microimaging to evaluate function and morphology. A further aim was to prove if this in vivo monitoring can be correlated to immunohistological data that indicates graft integrity. Methods: Murine infrarenal aortic isografts were orthotopically transplanted into 14 female mice (C57BL/6-Background) whereas a group of sham-operated animals (n = 10) served as controls. To assess the graft morphology and hemodynamics, we examined the mice over a post-operative period of 8 weeks with a sophisticated ultrasound system (Vevo 770, Visual Sonics). Results: The non-invasive graft monitoring was feasible in all transplanted mice. We could demonstrate a regular post-transplant graft function and morphology, such as anterior/posterior wall displacement and wall thickness. Mild alterations of anterior wall motion dynamics could only be observed at the site of distal graft anastomosis (8 weeks after grafting (transplant vs. sham mice: 0.02 mm ± 0.01 vs. 0.03 mm ± 0.01, p < 0.05). However, the integrity of the entire graft wall could be confirmed by histopathological evaluation of the grafts. Conclusions: With regard to graft patency, function and morphology, high resolution ultrasound microimaging has proven to be a valuable tool for longitudinal, non-invasive, in vivo graft monitoring in this murine aortic transplantation model. Consequently, this experimental animal model provides an excellent basis for molecular and pharmacological studies using genetically engineered mice.

  5. Renal cortical calcification in syngeneic intact rats and those receiving an infrarenal thoracic aortic graft: possible etiological roles of endothelin, nitrate and minerals, and different preventive effects of long-term oral treatment with magnesium, citrate and alkali-containing preparations.

    Science.gov (United States)

    Schmiedl, A; Schmiedl, P O; Bonucci, E; Seitz, T; Schwille, R M; Manoharan, M

    2001-08-01

    Renal cortical nephrocalcinosis (C-NC) is a rare disorder of uncertain etiology. Using highly inbred (syngeneic) male Lewis rats, we describe the spontaneous occurrence of histologically detectable C-NC in sham operated control rats (Sham; n=12), its aggravation following grafting of the ascending thoracic aorta from a donor rat to the infrarenal aorta of a recipient (ATx; n=12), and differences in C-NC inhibition after 12 weeks of oral administration of magnesium (Mg), citrate and alkali. C-NC is characterized by Kossa-positive areas located in cells of the proximal tubule close to blood vessels and also, to a lesser extent, within glomeruli. After ATx there was vascular overproduction of endothelin (ET-1) but decreased production of nitrate; in renal cortical tissue there was an excess of calcium over Mg and phosphorus and oxalate over citrate. In plasma there was an increase in calcium and creatinine within the normal range. Calcification of tubular cells was eliminated by a preparation containing potassium, sodium and bases (from citrate degradation and bicarbonate) in addition to Mg. Less effective than the latter was Mg-potassium citrate and least effective, Mg citrate. The former treatment also normalized calcemia and urinary nitrate, but only incompletely suppressed ET-1 and had no significant effect on glomerular calcification or tissue and urinary oxalate. Urinary ET-1 excess appeared directly related to the cortical tissue calcium/Mg ratio, and urinary excretion of Mg, citrate and total protein appeared to be inversely related to the severity of C-NC. It was concluded that (1) the highly inbred rat is prone to precipitation of calcium phosphate in the renal cortex; (2) this type of C-NC occurs in close proximity to and within renal vascular tissue and is associated with an imbalance of vasoconstrictors and vasodilators of endothelial origin; (3) effective inhibition of C-NC can be achieved by an alkalinizing combination of Mg, potassium, sodium and

  6. Directional tip control technique for optimal stent graft alignment in angulated proximal aortic landing zones

    Directory of Open Access Journals (Sweden)

    Toshio Takayama, MD, PhD

    2017-06-01

    Full Text Available Angulated anatomy in the aorta, such as tortuous infrarenal aortic necks or steep aortic arches, is a significant challenge for endovascular aortic repair because it often causes inadequate sealing and fixation, which may lead to treatment failure. We have developed a technique using off-the-shelf equipment to precisely control the deployment of stent grafts in challenging landing zones. The key of this technique is to create a through-and-through wire between two access sites and to use a guiding device over the wire. This technique is best used with stent grafts without nose cones. We present an endovascular aneurysm repair case and a thoracic endovascular aortic repair case with challenging proximal landing zones treated by this technique. In both cases, technical success was attained, and follow-up imaging demonstrated well-aligned stent grafts. Our directional tip control technique is easy and effective. It can be a good technical solution for endovascular aortic treatment in angulated anatomy.

  7. Cadaveric aorta implantation for aortic graft infection.

    Science.gov (United States)

    Ali, Asad; Bahia, Sandeep S S; Ali, Tahir

    2016-01-01

    This case report describes a 73-year-old gentleman who underwent explantation of an infected prosthetic aorto-iliac graft and replacement with a cryopreserved thoracic and aorto-iliac allograft. The patient has been followed up a for more than a year after surgery and remains well. After elective tube graft repair of his abdominal aortic aneurysm (AAA) in 2003, he presented to our unit in 2012 in cardiac arrest as a result of a rupture of the distal graft suture line due to infection. After resuscitation he underwent aorto-bifemoral grafting using a cuff of the original aortic graft proximally. Distally the new graft was anastomosed to his common femoral arteries, with gentamicin beads left in situ. Post discharge the patient was kept under close surveillance with serial investigations including nuclear scanning, however it became apparent that his new graft was infected and that he would require aortic graft replacement, an operation with a mortality of at least 50%. The patient underwent the operation and findings confirmed a synthetic graft infection. This tube graft was explanted and a cryopreserved aorta was used to the refashion the abdominal aorta and its bifurcation. The operation required a return to theatre day one post operatively for a bleeding side branch, which was repaired. The patient went on to make a full recovery stepping down from the intensive therapy unit day 6 post operatively and went on to be discharged 32 days after his cryopreserved aorta implantation. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  8. Fatal Saccharomyces Cerevisiae Aortic Graft Infection

    Science.gov (United States)

    Meyer, Michael (Technical Monitor); Smith, Davey; Metzgar, David; Wills, Christopher; Fierer, Joshua

    2002-01-01

    Saccharomyces cerevisiae is a yeast commonly used in baking and a frequent colonizer of human mucosal surfaces. It is considered relatively nonpathogenic in immunocompetent adults. We present a case of S. cerevisiae fungemia and aortic graft infection in an immunocompetent adult. This is the first reported case of S. cerevisiue fungemia where the identity of the pathogen was confirmed by rRNA sequencing.

  9. Primary Infrarenal Aortic Stenting With or Without Iliac Stenting for Isolated and Aortoiliac Stenoses: Single-Centre Experience With Long-Term Follow-Up

    International Nuclear Information System (INIS)

    Tapping, C. R.; Ahmed, M.; Scott, P. M.; Lakshminarayan, R.; Robinson, G. J.; Ettles, D. F.; Shrivastava, V.

    2013-01-01

    The purpose of this study was to evaluate the technical success, complications, long-term clinical outcome, and patency after primary infrarenal aortic stenting for aortic and aortoiliac stenosis. Between January 1999 and January 2006, 22 consecutive patients underwent endovascular treatment because of infrarenal aortic stenosis with and without common iliac stenosis (10 men; mean age 64 ± 14 years). Eleven (11 of 22) patients had an isolated aortic stenosis, whereas 11 of 22 had aortic stenosis that extended into the common iliac arteries (CIAs). Thirteen patients were Rutherford classification type 3, and 9 patients were type 4. Statistical analysis included paired Student t test and Kaplan–Meier life table analysis; p < 0.05 was considered significant. Technical and initial clinical success was achieved in all patients. There were three (14 %) procedure-related complications, which included two access-point pseudoaneurysms and one non–flow-limiting left external iliac dissection. Patients were followed-up for a mean period of 88 months (range 60–132). Mean preprocedure ankle brachial pressure indexes (ABPI) were 0.60 ± −0.15 (right) and 0.61 ± −0.16 (left). After the procedure they were 0.86 ± −0.07 (right) and 0.90 ± −0.09 (left). The increase in ABPI was significant (p < 0.05), and this continued throughout follow-up. Four (18 %) patients had recurrence of symptoms during follow-up. These occurred at 36, 48, 48, and 50 months after the original procedure. All four patients were successfully treated with repeat angioplasty procedures. There was a significant difference in primary patency between isolated aortic stenosis (100 %) and aortoiliac stenosis (60 %) (p = 0.031). Cumulative follow-up was 1920 months yielding a reintervention rate of 0.025/events/year. Primary stenting of infrarenal stenosis is safe and successful with a low reintervention rate. It should be considered as first-line treatment for patients with infrarenal aortic

  10. Dutch experience with the fenestrated Anaconda endograft for short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair.

    Science.gov (United States)

    Dijkstra, Martijn L; Tielliu, Ignace F J; Meerwaldt, Robbert; Pierie, Maurice; van Brussel, Jerome; Schurink, Geert Willem H; Lardenoye, Jan-Willem; Zeebregts, Clark J

    2014-08-01

    In the past decennium, the management of short-neck infrarenal and juxtarenal aortic aneurysms with fenestrated endovascular aneurysm repair (FEVAR) has been shown to be successful, with good early and midterm results. Recently, a new fenestrated device, the fenestrated Anaconda (Vascutek, Renfrewshire, Scotland), was introduced. The aim of this study was to present the current Dutch experience with this device. A prospectively held database of patients treated with the fenestrated Anaconda endograft was analyzed. Decision to treat was based on current international guidelines. Indications for FEVAR included an abdominal aortic aneurysm (AAA) with unsuitable neck anatomy for EVAR. Planning was performed on computed tomography angiography images using a three-dimensional workstation. Between May 2011 and September 2013, 25 patients were treated in eight institutions for juxtarenal (n = 23) and short-neck AAA (n = 2). Median AAA size was 61 mm (59-68.5 mm). All procedures except one were performed with bifurcated devices. A total of 56 fenestrations were incorporated, and 53 (94.6%) were successfully cannulated and stented. One patient died of bowel ischemia caused by occlusion of the superior mesenteric artery. On completion angiography, three type I endoleaks and seven type II endoleaks were observed. At 1 month of follow-up, all endoleaks had spontaneously resolved. Median follow-up was 11 months (range, 1-29 months). There were no aneurysm ruptures or aneurysm-related deaths and no reinterventions to date. Primary patency at 1 month of cannulated and stented target vessels was 96%. Initial and short-term results of FEVAR using the fenestrated Anaconda endograft are promising, with acceptable technical success and short-term complication rates. Growing experience and long-term results are needed to support these findings. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  11. Systematic review of recent evidence for the safety and efficacy of elective endovascular repair in the management of infrarenal abdominal aortic aneurysm.

    Science.gov (United States)

    Drury, D; Michaels, J A; Jones, L; Ayiku, L

    2005-08-01

    Conventional management of abdominal aortic aneurysm (AAA) is by open repair and is associated with a mortality rate of 2-6 per cent. Endovascular aneurysm repair (EVAR) is an alternative technique first introduced in 1991. A systematic review was undertaken of the evidence for the safety and efficacy of elective EVAR in the management of asymptomatic infrarenal AAA. Thirteen electronic bibliographical databases were searched, covering biomedical, health-related, science and social science literature. Outcomes were assessed with respect to efficacy (successful deployment, technical success, conversion rates and secondary intervention rates) and safety (30-day mortality rate, procedure morbidity rates and technical issues-endoleaks, graft thrombosis, stenosis and migration). Of 606 reports identified, 61 met the inclusion criteria (three randomized and 15 non-randomized controlled trials, and 43 uncontrolled studies). There were 29 059 participants in total; 19,804 underwent EVAR. Deployment was successful in 97.6 per cent of cases. Technical success (complete aneurysm exclusion) was 81.9 per cent at discharge and 88.8 per cent at 30 days. Secondary intervention to treat endoleak or maintain graft patency was required in 16.2 per cent of patients. Mean stay in the intensive care unit and mean hospital stay were significantly shorter following EVAR. The 30-day mortality rate for EVAR was 1.6 per cent (randomized controlled trials) and 2.0 per cent in nonrandomized trials and case series. Technical complications comprised stent migration (4.0 per cent), graft limb thrombosis (3.9 per cent), endoleak (type I, 6.8 per cent; type II, 10.3 per cent; type III, 4.2 per cent) and access artery injury (4.8 per cent). EVAR is technically effective and safe, with lower short-term morbidity and mortality rates than open surgery. However, there is a need for extended follow-up as the long-term success of EVAR in preventing aneurysm-related deaths is not yet known.

  12. Reduction in allogeneic blood products with routine use of autotransfusion in open elective infrarenal abdominal aortic aneurysm repair.

    Science.gov (United States)

    Courtemanche, Karim; Elkouri, Stephane; Dugas, Jean-Philippe; Beaudoin, Nathalie; Bruneau, Luc; Blair, Jean-François

    2013-11-01

    Concern about allogeneic blood product cost and complications has prompted interest in blood conservation techniques. Intraoperative autotransfusion (IAT) is currently not used routinely by vascular surgeons in open elective infrareanl abdominal aortic aneurysm (AAA) repair. The objective of this study is to review our experience with IAT and its impact on blood transfusion. We retrospectively reviewed the medical records of consecutive patients treated electively over a 4-year period and compared 2 strategy related to IAT, routine use IAT (rIAT) versus on-demand IAT (oIAT). Outcomes measured were number of units of allogeneic red blood cells and autologous red blood cells transfused intraoperatively and postoperatively, preoperative, postoperative, and discharge hemoglobin levels; postoperative infections; length of postoperative intensive care stay; and length of hospital stay. T-independent and Fisher exact test were used. A total of 212 patients were included, 38 (18%) in the rIAT and 174 (82%) in the oIAT. Groups were similar except for an inferior creatinine and a superior mean aneurysm diameter for the rIAT group. Patients in the rIAT group had a lower rate of transfusion (26% vs 54%, P = .002) and a lower mean number of blood unit transfused (0.8 vs 1.8, P = .048). These findings were still more significant for AAA larger than 60 mm (18% rIAT vs 62% oIAT, P = .0001). Postoperative hemoglobin was superior in the rIAT group (107 vs 101 g/L, P = .01). Mean postoperative intensive care length of stay was shorter for the rIAT group (1.1 vs 1.8 days, P = .01). No difference was noted for infection, mortality, or hospital length of stay. The rIAT reduced the exposure to allogeneic blood products by more than 50%, in particular for patients with AAA larger than 60 mm. These results support the use of rIAT for open elective infrarenal AAA repair.

  13. Percutaneous endovascular stent-graft treatment of aortic aneurysms and dissections: new techniques and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Choi, Dong Hoon; Kang, Sung Gwon; Lee, Kwang Hoon; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kang, Sung Gwon [Chosun University College of Medicine, Gwangju (Korea, Republic of); Won, Je Whan [Aju University College of Medicine, Suwon (Korea, Republic of); Song, Ho Young [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-01-01

    To evaluate the feasibility, safety and effectiveness of a newly designed percutaneously implanted separate stent-graft (SSG) for the treatment of aortic aneurysms and dissections. Using a percutaneous technique, SSG placement (in the descending thoracic aorta in 26 cases and infrarenal abdominal aorta in 24) was attempted in 50 patients with aortic aneurysms (n=27) or dissection (n=23). All SSGs were individually constructed using self-expandable nitinol stents and a Dacron graft, and were introduced through a 12 F sheath and expanded to a diameter of 20-34 mm. In all cases, vascular access was through the femoral artery. The clinical status of each patient was monitored, and postoperative CT was performed within one week of the procedure and at 3-6 month intervals afterwards. Endovascular stent-graft deployment was technically successful in 49 of 50 patients (98%). The one failure was due to torsion of the unsupported graft during deployment. Successful exclusion of aneurysms and the primary entry tears of dissections was achieved in all but three patients with aortic dissection. All patients in whom technical success was achieved showed complete thrombosis of the thoracic false lumen or aneurysmal sac, and the overall technique success rate was 92%. In addition, sixteen patients demonstrated complete resolution of the dissected thoracic false lumen (n=9) or aneurysmal sac (n=7). Immediate post-operative complications occurred at the femoral puncture site in one patient with an arteriovenous fistula, and in two, a new saccular aneurysm developed at the distal margin of the stent. No patients died, and there was no instance of paraplegia, stroke, side-branch occlusion or infection during the subsequent mean follow-up period of 9.4 (range, 2 to 26) months. In patients with aortic aneurysm and dissection, treatment with a separate percutaneously inserted stent-graft is technically feasible, safe, and effective.

  14. Why routine intensive care unit admission after elective open infrarenal Abdominal Aortic Aneurysm repair is no longer an evidence based practice.

    LENUS (Irish Health Repository)

    Ryan, David

    2012-01-31

    BACKGROUND: Elective open infrarenal Abdominal Aortic Aneurysm (AAA) repair is major surgery performed on high-risk patients. Routine ICU admission postoperatively is the current accepted standard of care. Few of these patients actually require a level of care that cannot be provided just as effectively in a surgical high dependency unit (HDU). Our aim was to determine, \\'can high risk patients that will require ICU admission postoperatively be reliably identified preoperatively?\\'. METHODS: A retrospective analysis of all elective open infrarenal AAA repairs in our institution over a 3-year period was performed. The Estimation of Physiological Ability and Surgical Stress (E-PASS) model was used as our risk stratification tool for predicting post-operative morbidity. Renal function was also considered as a predictor of outcome, independent of the E-PASS. RESULTS: 80% (n = 16) were admitted to ICU. Only 30% (n = 6) of the total study population necessitated intensive care. There were 9 complications in 7 patients in our study. The E-PASS comprehensive risk score (CRS)\\/Surgical stress score (SSS) were found to be significantly associated with the presence of a complication (p = 0.009)\\/(p = 0.032) respectively. Serum creatinine (p = 0.013) was similarly significantly associated with the presence of a complication. CONCLUSIONS: The E-PASS model possessing increasing external validity is an effective risk stratification tool in safely deciding the appropriate level of post-operative care for elective infrarenal AAA repairs.

  15. Fatores de morbimortalidade na cirurgia eletiva do aneurisma da aorta abdominal infra-renal: experiência de 134 casos Morbidity and mortality factors in the elective surgery of infrarenal abdominal aortic aneurysm: a case study with 134 patients

    Directory of Open Access Journals (Sweden)

    Aquiles Tadashi Ywata de Carvalho

    2008-09-01

    aortic aneurysm (AAA can result in serious complications. To optimize treatment outcome it is important to identify patients at risk of having complications and implement prophylaxis. OBJECTIVES: To analyze early surgical mortality rate and postsurgical complications, and to identify risk factors related to morbidity and mortality. METHOD: A total of 134 patients with infrarenal AAA submitted to elective surgical correction from February 2001 to December 2005 were analyzed. RESULTS: The mortality rate (5.2% was secondary mainly to acute myocardial infarction and intestinal ischemia. Heart-related complications were the most frequent, followed by lung and kidney complications. Presence of diabetes mellitus, congestive heart failure, coronary artery disease, and scintigraphy suggestive of ischemia were related to cardiac complications. Advanced age, chronic obstructive lung disease and reduced forced vital capacity were related to higher risks of atelectasis and pulmonary infection. Presence of renal failure, prolonged aortic clamping and high urea rates were related to acute renal failure. Smoking and advanced age were associated with lower limb ischemia. Presence of obstructive coronary insufficiency and prolonged aortic clamping and surgery time were associated with higher mortality rate. CONCLUSION: The morbidity and mortality rate was compatible with data found in the national and international literature, secondary to cardiac, pulmonary and kidney complications. Identified risk factors before and during the surgery were related to these complications.

  16. Current Role of Imaging in Diagnosing Aortic Graft Infections

    NARCIS (Netherlands)

    Bruggink, Janneke L. M.; Slart, Riemer H. J. A.; Pol, Jillis A.; Reijnen, Michel M. P. J.; Zeebregts, Clark J.

    2011-01-01

    Vascular prosthetic graft infection is a rare but serious complication after aortic graft replacement, with high morbidity and mortality rates. Therefore, adequate diagnostics are needed to detect and treat these infections as early as possible. Several imaging modalities provide different

  17. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    International Nuclear Information System (INIS)

    Saha, Prakash; Hughes, John; Patel, Ashish S.; Donati, Tommaso; Sallam, Morad; Patel, Sanjay D.; Bell, Rachel E.; Katsanos, Konstantinos; Modarai, Bijan; Zayed, Hany A.

    2015-01-01

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities

  18. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Prakash, E-mail: prakash.2.saha@kcl.ac.uk; Hughes, John, E-mail: johnhughes387@rocketmail.com; Patel, Ashish S., E-mail: ashish.s.patel@kcl.ac.uk; Donati, Tommaso, E-mail: tommaso.donati@gstt.nhs.uk; Sallam, Morad, E-mail: morad.sallam@gstt.nhs.uk; Patel, Sanjay D., E-mail: sanjay.patel@gstt.nhs.uk; Bell, Rachel E. [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Modarai, Bijan, E-mail: bijan.modarai@kcl.ac.uk; Zayed, Hany A., E-mail: hany.zayed@gstt.nhs.uk [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities.

  19. Long-term decline in renal function is more significant after endovascular repair of infrarenal abdominal aortic aneurysms.

    Science.gov (United States)

    Al Adas, Ziad; Shepard, Alexander D; Nypaver, Timothy J; Weaver, Mitchell R; Maatman, Thomas; Yessayan, Lenar T; Balraj, Praveen; Kabbani, Loay S

    2018-03-20

    It is not clear whether endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) results in an increase in renal insufficiency during the long term compared with open repair (OR). We reviewed our experience with AAA repair to determine whether there was a significant difference in postoperative and long-term renal outcomes between OR and EVAR. A retrospective cohort study was conducted of all patients who underwent AAA repair between January 1993 and July 2013 at a tertiary referral hospital. Demographics, comorbidities, preoperative and postoperative laboratory values, morbidity, and mortality were collected. Patients with ruptured AAAs, preoperative hemodialysis, juxtarenal or suprarenal aneurysm origin, and no follow-up laboratory values were excluded. Preoperative, postoperative, 6-month, and yearly serum creatinine values were collected. Glomerular filtration rate (GFR) was calculated on the basis of the Chronic Kidney Disease Epidemiology Collaboration equation. Acute kidney injury (AKI) was classified using the Kidney Disease: Improving Global Outcomes guidelines. Change in GFR was defined as preoperative GFR minus the GFR at each follow-up interval. Comparison was made between EVAR and OR groups using multivariate logistics for categorical data and linear regression for continuous variables. During the study period, 763 infrarenal AAA repairs were performed at our institution; 675 repairs fit the inclusion criteria (317 ORs and 358 EVARs). Mean age was 73.9 years. Seventy-nine percent were male, 78% were hypertensive, 18% were diabetic, and 31% had preoperative renal dysfunction defined as GFR below 60 mL/min. Using a multivariate logistic model to control for all variables, OR was found to have a 1.6 times greater chance for development of immediate postoperative AKI compared with EVAR (P = .038). Hypertension and aneurysm size were independent risk factors for development of AKI (P = .012 and .022, respectively). Using a linear

  20. Retroperitoneal aortic hemorrhage caused by penetration of an endovascular stent-graft anchoring barb.

    Science.gov (United States)

    Twine, Christopher P; Winterbottom, Andrew; Shaida, Nadeem; Boyle, Jonathan R

    2013-08-01

    To report a rare case of acute intraoperative retroperitoneal hemorrhage secondary to aortic penetration by the suprarenal anchoring barb on a stent-graft. A 75-year-old patient on dual antiplatelet therapy for coronary stents and low-molecular-weight heparin for atrial thrombus underwent elective endovascular repair of a 6.7-cm infrarenal abdominal aortic aneurysm. A device with suprarenal fixation and metal anchoring barbs was implanted, and a molding balloon was used that at no time covered the proximal bare metal stents or barbs. In recovery, the patient became tachycardic and hypotensive. After resuscitation, imaging identified an anterior barb penetrating the aortic wall, causing the acute retroperitoneal hemorrhage. A decision to treat conservatively rather than resort to open surgery was difficult but ultimately influenced by the patients' high risk for open surgery. The patient was treated by aggressive reversal of heparin and platelet transfusion, and the bleed settled spontaneously. Major surgery and subsequent morbidity may be avoided by medical management of what would appear to be a surgical problem.

  1. Aortic root surgery in Marfan syndrome: Comparison of aortic valve-sparing reimplantation versus composite grafting.

    Science.gov (United States)

    Karck, Matthias; Kallenbach, Klaus; Hagl, Christian; Rhein, Christine; Leyh, Rainer; Haverich, Axel

    2004-02-01

    The objective of this study was to compare the results of aortic valve-sparing reimplantation and aortic root replacement with mechanical valve conduits in patients with Marfan syndrome undergoing operation for aortic root aneurysms. Patients and methods Between March 1979 and April 2002, 119 patients with clinical evidence of Marfan syndrome underwent composite graft replacement with mechanical valve conduits (n = 74) or aortic valve-sparing reimplantation according to David (n = 45). The underlying causes were aortic dissection type A (43 patients) and aneurysms (76 patients). Patients undergoing aortic valve reimplantation were younger compared with patients undergoing composite grafting (28 vs 35 years, P =.002) and had longer intraoperative aortic crossclamp times (125 vs 78 minutes, P valve reimplantation (P =.15). Mean follow-up was 30 months for patients undergoing aortic valve reimplantation and 114 months for patients undergoing composite grafting. Freedom from reoperation and death after 5 years postoperatively was 92% and 89% in patients undergoing composite grafting and 84% and 96% in patients undergoing aortic valve reimplantation (P =.31; P =.54), respectively. Thromboembolic complications or late postoperative bleeding occurred in 17 patients undergoing composite grafting, and an early postoperative event occurred in 1 patient undergoing aortic valve reimplantation. The results of aortic valve reimplantation and composite grafting of the aortic valve and ascending aorta with mechanical valve conduits are similar with regard to early and mid-term postoperative mortality and to the incidence of late reoperations in patients with Marfan syndrome. The low risk of thromboembolic or bleeding complications favors aortic valve reimplantation in these patients.

  2. Computerized tomographic evaluation of aortic prosthetic graft complications

    International Nuclear Information System (INIS)

    Kay, D.; Kalmar, J.A.

    1985-01-01

    Computerized tomography has been found to be an accurate and sensitive method of diagnosing complications of synthetic aortic grafts. Complications in this series of four cases included aortoesophageal fistula, aortoduodenal fistula, pseudoaneurysm, and retroperitoneal hematoma. 6 references, 5 figures

  3. Endovascular stent-graft management of thoracic aortic diseases

    International Nuclear Information System (INIS)

    Dake, Michael D.

    2001-01-01

    The traditional standard therapy for descending thoracic aortic aneurysm (TAA) is open operative repair with graft replacement of the diseased aortic segment. Despite important advances in surgical techniques, anesthetic management, and post-operative care over the last 30 years, the mortality and morbidity of surgery remains considerable, especially in patients at high risk for thoracotomy because of coexisting severe cardiopulmonary abnormalities or other medical diseases. The advent of endovascular stent-graft technology provides an alternative to open surgery for selected patients with TAA. The initial experience suggests that stent-graft therapy potentially may reduce the operative risk, hospital stay and procedural expenses of TAA repair. These potential benefits are especially attractive for patients at high risk for open TAA repair. Current results of endovascular TAA therapy document operative mortalities of between 0 and 4%, aneurysm thrombosis in 90 and 100% of cases, and paraplegia as a complication in 0 and 1.6% of patients. The early success of stent-graft repair of TAA has fostered the application of these devices for the management of a wide variety of thoracic aortic pathologies, including acute and chronic dissection, intramural hematoma, penetrating ulcer, traumatic injuries, and other diseases. The results of prospective controlled trials that compare the outcomes of stent-graft therapy with those of surgical treatment in patients with specific types of aortic disease are anxiously awaited before recommendations regarding the general use of these new devices can be made with confidence

  4. Infrarenal aorta as the donor site for bypasses to the superior mesenteric artery for chronic mesenteric ischemia: A prospective clinical series of 24 patients.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Calio', Francesco G; Pasqua, Rocco; Masci, Federica; Vietri, Francesco

    2017-11-01

    Treatment of symptomatic, chronic mesenteric ischemia is indicated to relieve symptoms and prevent acute ischemia and death. Current therapeutic options include endovascular and open surgery. The purpose of this prospective study was to evaluate the results of bypasses to the superior mesenteric artery arising from the infrarenal aorta or infrarenal aortic grafts. From January 1999 to December 2016, 24 consecutive patients with a mean age of 61 years underwent a prosthetic bypass to the superior mesenteric artery. Nine patients (37%) presented with an associated clinically important stenosis of the celiac artery and 10 (42%) of the inferior mesenteric artery. Five patients (21%) received preoperative parenteral nutrition. Four patients (17%) underwent dual antiplatelet treatment. The donor site was the infrarenal aorta in 19 patients (79%) and an infrarenal, Dacron graft was used in 5 (21%). The origin of the bypass was from the distal infrarenal aorta or Dacron graft in 19 patients (79%) and from the proximal infrarenal aorta in 5 patients (21%). The graft material consisted of 7 mm polytetrafluoroethylene in 19 cases (79%) and 7 mm Dacron in 5 cases (21%). A concomitant bypass to the inferior mesenteric artery was performed in 4 patients (17%). The primary end points were postoperative mortality, morbidity, graft infection, late survival, primary patency, and symptom-free rate. The secondary end point was postoperative hemorrhagic complications. No postoperative mortality occurred. Postoperative morbidity included a prolonged postoperative ileus in 4 patients (17%), transitory postoperative increases in serum creatinine concentrations in 3 patients (12%), and myocardial ischemia in 2 patients (8%). No postoperative hemorrhagic complications or graft infection were observed. Overall, the cumulative survival rate was 77% at 60 months. The overall late-patency rate and freedom from recurrence of symptoms were both 87% at 60 months. Infrarenal aorta and

  5. Open Repair of Mycotic Abdominal Aortic Aneurysms With Biological Grafts

    DEFF Research Database (Denmark)

    Heinola, Ivika; Sörelius, Karl; Wyss, Thomas R

    2018-01-01

    BACKGROUND: The treatment of mycotic abdominal aortic aneurysm requires surgery and antimicrobial therapy. Since prosthetic reconstructions carry a considerable risk of reinfection, biological grafts are noteworthy alternatives. The current study evaluated the durability, infection resistance......, and midterm outcome of biological grafts in treatment of mycotic abdominal aortic aneurysm. METHODS AND RESULTS: All patients treated with biological graft in 6 countries between 2006 and 2016 were included. Primary outcome measures were 30- and 90-day survival, treatment-related mortality, and reinfection...... rate. Secondary outcome measures were overall mortality and graft patency. Fifty-six patients (46 males) with median age of 69 years (range 35-85) were included. Sixteen patients were immunocompromised (29%), 24 (43%) had concomitant infection, and 12 (21%) presented with rupture. Bacterial culture...

  6. Endovascular Treatment of Infrarenal Abdominal Aortic Aneurysm with Short and Angulated Neck in High-Risk Patient

    Directory of Open Access Journals (Sweden)

    Stylianos Koutsias

    2013-01-01

    Full Text Available Endovascular treatment of abdominal aortic aneurysms (AAA is an established alternative to open repair. However lifelong surveillance is still required to monitor endograft function and signal the need for secondary interventions (Hobo and Buth 2006. Aortic morphology, especially related to the proximal neck, often complicates the procedure or increases the risk for late device-related complications (Hobo et al. 2007 and Chisci et al. 2009. The definition of a short and angulated neck is based on length (60° (Hobo et al. 2007 and Chisci et al. 2009. A challenging neck also offers difficulties during open repairs (OR, necessitating extensive dissection with juxta- or suprarenal aortic cross-clamping. Patients with extensive aneurysmal disease typically have more comorbidities and may not tolerate extensive surgical trauma (Sarac et al. 2002. It is, therefore, unclear whether aneurysms with a challenging proximal neck should be offered EVAR or OR (Cox et al. 2006, Choke et al. 2006, Robbins et al. 2005, Sternbergh III et al. 2002, Dillavou et al. 2003, and Greenberg et al. 2003. In our case the insertion of a thoracic endograft followed by the placement of a bifurcated aortic endograft for the treatment of a very short and severely angulated neck proved to be feasible offering acceptable duration of aneurysm exclusion. This adds up to our armamentarium in the treatment of high-risk patients, and it should be considered in emergency cases when the fenestrated and branched endografts are not available.

  7. Endovascular abdominal aortic repair for AAA. Anatomical suitability and limitation in Japanese population according to the inclusion criteria of Zenith AAA stent graft

    International Nuclear Information System (INIS)

    Kitagawa, Atsushi; Okita, Yutaka; Okada, Kenji

    2009-01-01

    Since 2007, the EVAR (endovascular abdominal aortic repair) grafts, Zenith, Excluder and Powerlink had been commercially available in Japan. However, a small iliac artery, typical of Japanese population especially in women, was a limiting factor to indicate EVAR. We analyzed the suitability of EVAR in Japanese population according to the inclusion criteria of Zenith AAA stent graft in the current study. From January 2006 to December 2007, 106 AAA (abdominal aortic aneurysm) patients (88 men, 18 women) with a mean age of 73 years were investigated in our institution by multi-slice CT scan in terms of suitability of EVAR, then we measured their abdominal aorta and iliac artery parameters as follows; proximal neck diameter (PND) and length (PNL), common iliac artery diameter (CIAD) and length (CIAL), suprarenal (SNA) and infrarenal neck angulation (INA), external iliac artery diameter (EIAD) and aortic length from the lowest renal artery to the aortic bifurcation (AOL). The inclusion criteria for Zenith AAA stent graft treatment were; PND: 18-28 mm, PNL more than 15 mm, unilateral CIAD less than 20 mm, CIAL at least 10 mm, SNA less than 45 degree and INA less than 60 degree, unilateral EIAD more than 7.5 mm. The indication of EVAR was 25.5% (27/106 patients), and was especially very low in women (5.6%) strictly according to the inclusion criteria of the Zenith AAA stent graft. The main reason of exclusion of EVAR was proximal short neck (40.5%), small iliac artery (30.4%) and infrarenal aortic neck angulation (29.1%). In our analysis, female AAA patients had small PNL and EIAD with angulated neck compared with male AAA ones. Anatomical suitability of EVAR in Japanese population strictly following by the inclusion criteria of Zenith AAA stent graft was low due to their characteristic differences from the European Union (EU) and the United States (US) patients, such as short proximal neck, steep neck angulation and small iliac artery, especially in women. More flexible

  8. The Effect of Infrarenal Aortic Balloon Occlusion on Weaning from Supraceliac Aortic Balloon Occlusion in a Porcine Model (Sus scrofa) of Hemorrhagic Shock

    Science.gov (United States)

    2017-06-15

    all animals , and continued for six hours. Half of the animals were randomly assigned to Zone-3 REBOA for an additional 45 minutes following Zone-1...concentration or resuscitation requirements.Conclusion: In an animal model of hemorrhagic shock and Zone-1 REBOA, subsequent Zone-3 aortic occlusion did not add

  9. New graft sizing rings for aortic valve reimplantation procedures.

    Science.gov (United States)

    Jelenc, Matija; Jelenc, Blaž; Kneževic, Ivan; Klokocovnik, Tomislav

    2018-01-01

    The objective was to design sizing rings that would enable proper sizing of the graft in reimplantation procedures and to perform leaflet repair before graft implantation. The rings were designed in Autodesk Fusion 360 (San Rafael, CA, USA) and 3D printed using a commercial online 3D printing service. We designed incomplete rings with a low profile and complete rings with a high profile. The complete rings are best suited for reimplantation procedures, whereas low profile C rings are intended for isolated aortic valve repair, where the ascending aorta is not transected. The rings come in sizes corresponding to Vascutek Gelweave graft sizes (Vascutek Terumo, Renfrewshire, Scotland). The ring internal diameters are 5% larger than the designated ring sizes and account for the 5% stretch of the grafts when pressurized. Blades of the rings are placed at 20° intervals. The slits between the blades are designed in such a way that the commissural U-sutures, when put in place and under tension, will lock the ring in position. The rings were successfully used in 10 of our latest reimplantation procedures. After dissection of the aortic root, the commissures were suspended with U-stitches and then the ring was seated onto them. Complete leaflet repair with plication to achieve adequate effective height was then performed, followed by graft implantation. No additional leaflet repair was needed. The newly designed sizing rings enable proper sizing of the graft in reimplantation procedures and enable complete leaflet repair before graft implantation. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rakesh P., E-mail: rpatel9@nhs.net [Northwick Park Hospital, Department of Vascular Radiology (United Kingdom); Katsargyris, Athanasios, E-mail: kthanassos@yahoo.com; Verhoeven, Eric L. G., E-mail: Eric.Verhoeven@klinikum-nuernberg.de [Klinikum Nuernberg, Department of Vascular and Endovascular Surgery (Germany); Adam, Donald J., E-mail: donald.adam@tiscali.co.uk [Heartlands Hospital, Department of Vascular Surgery (United Kingdom); Hardman, John A., E-mail: johnhardman@doctors.org.uk [Royal United Hospital Bath, Department of Vascular Radiology (United Kingdom)

    2013-12-15

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  11. Abdominal aortic aneurysm neck remodeling after Anaconda stent graft implantation.

    Science.gov (United States)

    Vukovic, Elisabeth; Czerny, Martin; Beyersdorf, Friedhelm; Wolkewitz, Martin; Berezowski, Mikolaj; Siepe, Matthias; Blanke, Philipp; Rylski, Bartosz

    2018-05-24

    The aim of this study was to define how the proximal landing zone changes geometrically after endovascular abdominal aortic aneurysm repair (EVAR) with the Anaconda (Vascutek, Inchinnan, United Kingdom) stent graft. Among 230 patients who underwent Anaconda stent graft implantation between 2005 and 2014, we included 126 with adequate computed tomography (CT) image quality and follow-up. CT analysis entailed the geometric changes in the main body, proximal rings, and proximal landing zone. The median CT follow-up was 2.0 years (345.8 patients-years). The proximal portion of the main body ring system flattened within the first year after EVAR, resulting in an up to 30° increase in the upper ring's angle in 40% patients and up to 40° increase in 24% patients. One year after EVAR, the upper ring angle increase slowed down. Aortic diameter measured at the level of the upper and lower ring expanded by 2 to 4 mm within 1 year, but remained unchanged afterward. The main body migrated continuously down toward the aortic bifurcation, attaining an average 6-mm increase in the distance between the superior mesenteric artery and main body within 4 years. Freedom from endoleak type IA was 95 ± 2% and 93 ± 3% after 1 and 4 years, respectively. The Anaconda main body ring system in its proximal portion flattens within the first year after EVAR, leading to an increase of 2 to 4 mm in the proximal landing zone's aortic diameter. The main body migrates slowly but continuously down toward the aortic bifurcation. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  12. Aortic Arch Aneurysms: Treatment with Extra anatomical Bypass and Endovascular Stent-Grafting

    International Nuclear Information System (INIS)

    Kato, Noriyuki; Shimono, Takatsugu; Hirano, Tadanori; Mizumoto, Toru; Ishida, Masaki; Fujii, Hideki; Yada, Isao; Takeda, Kan

    2002-01-01

    Endovascular repair of thoracic aortic aneurysms is emerging as an attractive alternative to surgical graft replacement. However,patients with aortic arch aneurysms are often excluded from the target of endovascular repair because of lack of suitable landing zones, especially at the proximal ones. In this paper we describe our method for treating patients with aortic arch aneurysms using a combination of extra anatomical bypass surgery and endovascular stent-grafting

  13. Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft.

    LENUS (Irish Health Repository)

    Molony, David S

    2009-01-01

    BACKGROUND: Abdominal aortic aneurysms (AAA) are local dilatations of the infrarenal aorta. If left untreated they may rupture and lead to death. One form of treatment is the minimally invasive insertion of a stent-graft into the aneurysm. Despite this effective treatment aneurysms may occasionally continue to expand and this may eventually result in post-operative rupture of the aneurysm. Fluid-structure interaction (FSI) is a particularly useful tool for investigating aneurysm biomechanics as both the wall stresses and fluid forces can be examined. METHODS: Pre-op, Post-op and Follow-up models were reconstructed from CT scans of a single patient and FSI simulations were performed on each model. The FSI approach involved coupling Abaqus and Fluent via a third-party software - MpCCI. Aneurysm wall stress and compliance were investigated as well as the drag force acting on the stent-graft. RESULTS: Aneurysm wall stress was reduced from 0.38 MPa before surgery to a value of 0.03 MPa after insertion of the stent-graft. Higher stresses were seen in the aneurysm neck and iliac legs post-operatively. The compliance of the aneurysm was also reduced post-operatively. The peak Post-op axial drag force was found to be 4.85 N. This increased to 6.37 N in the Follow-up model. CONCLUSION: In a patient-specific case peak aneurysm wall stress was reduced by 92%. Such a reduction in aneurysm wall stress may lead to shrinkage of the aneurysm over time. Hence, post-operative stress patterns may help in determining the likelihood of aneurysm shrinkage post EVAR. Post-operative remodelling of the aneurysm may lead to increased drag forces.

  14. Juxtarenal Modular Aortic Stent Graft Infection Caused by Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    Róbert Novotný

    2016-01-01

    Full Text Available Introduction. We are presenting a case report of an infected modular abdominal stent graft. Case Presentation. A 67-year-old male patient three years after Cook’s modular abdominal aortic aneurysm (AAA graft implantation for juxtarenal AAA with an implantation of a stent extension into the right common iliac artery for type Ib endoleak. The patient was admitted into our center in severe condition with suspected retroperitoneal bleeding. Computed tomography angiography (CTAG confirmed retroperitoneal bleeding in the right common iliac artery. An urgent surgical revision was indicated; destructed arterial wall around the stent extension in the right common iliac artery was discovered. Due to the severe state of health of the patient, a resection of the infected stent and affected arterial wall was performed, followed by an iliac-femoral crossover bypass. The patient was transported to the intensive care unit with hepatic and renal failure, with maximal catecholamine support. Combined antibiotic treatment was started. The patient died five hours after the procedure. The cause of death was multiorgan failure caused by sepsis. Hemocultures and perioperative microbiological cultures showed the infection agent to be Staphylococcus aureus methicillin sensitive. Conclusion. Stent graft infection is a rare complication. Treatment is associated with high mortality and morbidity.

  15. Hypertrophic osteoarthropathy of one leg - a sign of aortic graft infection

    Energy Technology Data Exchange (ETDEWEB)

    Spruijt, S.; Krijgsman, A.A. [Department of Orthopaedic and Trauma Surgery, Elkerliek Hospital, Helmond (Netherlands); Broek, J.A.C. van den [Department of Radiology, Elkerliek Hospital, Helmond (Netherlands); Tutein Nolthenius-Puylaert, M.C.B.J.E. [Department of Pathology, Elkerliek Hospital, Helmond (Netherlands)

    1999-04-01

    We report a rare case of hypertrophic osteoarthropathy (HOA) confined to the right leg secondary to aortic graft infection. The development of HOA exclusively localized to areas distal to a vascular prosthesis may be the presenting manifestation of graft infection and a crucial diagnostic clue in the early detection of vascular graft infection. HOA is diagnosed by its characteristic radiographic and scintigraphic pattern. Most prosthetic, especially aortic, graft infections are uniformly fatal if not treated by aggressive surgical and antibiotic therapy. Recognition of this uncommon association may facilitate an early diagnosis, which usually requires immediate surgical therapy. (orig.) With 6 figs., 28 refs.

  16. Hypertrophic osteoarthropathy of one leg - a sign of aortic graft infection

    International Nuclear Information System (INIS)

    Spruijt, S.; Krijgsman, A.A.; Broek, J.A.C. van den; Tutein Nolthenius-Puylaert, M.C.B.J.E.

    1999-01-01

    We report a rare case of hypertrophic osteoarthropathy (HOA) confined to the right leg secondary to aortic graft infection. The development of HOA exclusively localized to areas distal to a vascular prosthesis may be the presenting manifestation of graft infection and a crucial diagnostic clue in the early detection of vascular graft infection. HOA is diagnosed by its characteristic radiographic and scintigraphic pattern. Most prosthetic, especially aortic, graft infections are uniformly fatal if not treated by aggressive surgical and antibiotic therapy. Recognition of this uncommon association may facilitate an early diagnosis, which usually requires immediate surgical therapy. (orig.)

  17. Effect of Graft Material on Red Blood Cell Loss Following Aortic Surgery

    National Research Council Canada - National Science Library

    Fisher, Jay

    1990-01-01

    ... (Meadox Woven Double Velour) and PTFE (Gore-Tex) grafts. A total of 25 patients (13 Dacron, 12 PTFE) were studied including 21 with abdominal aortic aneurysms, and 4 with aorto-iliac occlusive disease...

  18. Exophiala (Wangiella dermatitidis Prosthetic Aortic Valve Endocarditis and Prosthetic Graft Infection in an Immune Competent Patient

    Directory of Open Access Journals (Sweden)

    Jay S. Berger

    2017-01-01

    Full Text Available Exophiala (Wangiella dermatitidis is an emerging dematiaceous fungus associated with high mortality rates and is a rare cause of endocarditis. We describe the first case of E. dermatitidis endocarditis of a prosthetic aortic valve and aortic graft in an immune competent patient with no clear risk factors of hematological acquisition.

  19. Dilatation of aortic grafts over time: what to expect and when to be concerned

    DEFF Research Database (Denmark)

    Schroeder, Torben V; Eldrup, Nikolaj; Just, Sven

    2009-01-01

    Dilatation of aortic prosthetic grafts is commonly reported, but most reports are anecdotal, with little objective data in the literature. We performed a prospective trial of 303 patients who underwent prosthetic graft repair for aortic aneurysm or occlusive disease, randomizing patients between...... insertion of a woven polyester or expanded polytetrafluoroethylene (ePTFE) graft. Patients were followed with computed tomography and ultrasonography for up to 5 years in order to assess the frequency and magnitude of postoperative dilatation. Graft dilatation was documented in patients with polyester...... grafts at 12 months. Thereafter and up to 60 months, polyester grafts did not dilate further. After 5 years, polyester prostheses had dilated by 25% and ePTFE by 12.5%, as determined by computed tomography imaging. These observations suggest that dilatation of prosthetic grafts is more frequent...

  20. Endovascular stent-graft exclusion of aortic dissection combined with renal failure

    International Nuclear Information System (INIS)

    Feng Xiang; Jing Zaiping; Yuan Weijie; Bao Junmin; Zhao Zhiqing; Zhao Jun; Lu Qingsheng

    2003-01-01

    Objective: To investigate the indications and peri-operative management of endovascular graft exclusion of aortic dissection combined with renal failure. Methods: Endovascular graft exclusion for Stanford B type thoracic aortic dissection had been preformed on 136 patients including two complicated with renal failure. Hemodialysis was preformed before operation with the fluid infusion controlled during the operation and bed-side hemodialysis after the operation for the latter. Results: All the 2 cases with renal failure complication were successfully carried out, and the peri-operative metabolism and circulation were kept on smoothly. Conclusions: Under good peri-operative management, patients having aortic dissection combined with renal failure could receive the endovascular graft exclusion of aortic dissection safely

  1. Endovascular Retrieval of Entrapped Elephant Trunk Graft During Complex Hybrid Aortic Arch Repair

    Energy Technology Data Exchange (ETDEWEB)

    Damodharan, Karthikeyan, E-mail: drdkarthik@hotmail.com [Singapore General Hospital, Department of Diagnostic Radiology (Singapore); Chao, Victor T. T., E-mail: victor.chao.t.t@singhealth.com.sg [National Heart Centre, Department of Cardiothoracic Surgery (Singapore); Tay, Kiang Hiong, E-mail: tay.kiang.hiong@singhealth.com.sg [Singapore General Hospital, Department of Diagnostic Radiology (Singapore)

    2016-12-15

    Entrapment of the elephant trunk graft within the false lumen is a rare complication of surgical repair of an aortic dissection. This is normally retrieved by emergent open surgery. We describe a technique of endovascular retrieval of the dislodged graft, during hybrid aortic arch repair. The elephant trunk was cannulated through and through from a femoral access and the free end of the wire was snared and retrieved from a brachial access. The wire was externalised from both accesses and was used to reposition the graft into the true lumen using a body flossing technique.

  2. Tissue Responses to Stent Grafts with Endo-Exo-Skeleton for Saccular Abdominal Aortic Aneurysms in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il Young; Chung, Jin Wook; Kim, Hyo Cheol [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul (Korea, Republic of); Choi, Young Ho; So Young Ho [Dept. of Radiology, Seoul National University Boramae Hospital, Seoul (Korea, Republic of); Kim, Hyun Beom [Dept. of Radiology, National Cancer Center, Goyang (Korea, Republic of); Min, Seung Kee [Dept. of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2014-10-15

    We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing the animals, the aortas with an embedded stent graft were excised. The aortas were inspected grossly and evaluated microscopically. The animals were sacrificed at two (n = 3), six (n = 3), and eight months (n = 2) after endovascular repair. In two dogs, the aortic lumen was occluded at two months after the placement. On gross inspection of specimens from the other six dogs with a patent aortic lumen, stent grafts placed over the normal aortic wall were covered by glossy white neointima, whereas, stent grafts placed over the aneurysmal aortic wall were covered by brownish neointima. On microscopic inspection, stent grafts placed over the normal aortic wall were covered by thin neointima (0.27 ± 0.05 mm, mean ± standard deviation) with an endothelial layer, and stent grafts placed over the aneurysmal aortic wall were covered by thick neointima (0.62 ± 0.17 mm) without any endothelial lining. Transgraft cell migration at the normal aortic wall was more active than that at the aneurysmal aortic wall. Close contact between the stent and the graft, which was achieved with stent grafts with endo-exo-skeleton, could not enhance endothelial covering on the stent graft placed over the aneurysms.

  3. Late type III endoleak after thoracic endovascular aneurysm repair and previous infrarenal stent graft implantation - a case report and review of the literature.

    Science.gov (United States)

    Leszczyński, Jerzy; Macioch, Waldemar; Chudziński, Witold; Gałązka, Zbigniew

    2017-09-01

    Thoracic endovascular aortic repair (TEVAR) effectively improved the results of thoracic aortic aneurysm treatment. TEVAR is a less invasive procedure that can be performed under local anesthesia with shorter hospital stay. The perioperative morbidity and mortality rates are lower for endovascular than open repair, but the rate of secondary interventions is higher for TEVAR. We report a case of an elderly man with synchronous abdominal and thoracic aortic aneurysms. A type III dangerous endoleak was recognized 3 years after TEVAR. It was successfully repaired during an endovascular procedure. There were no new endoleaks after 12 months of follow-up. TEVAR may be the only option of treatment for risky and elderly patients. However, postoperative monitoring is necessary to exclude different types of endoleaks. Most of them undergo effective endovascular repair.

  4. Management of aortic graft infections - the present strategy and future perspectives.

    Science.gov (United States)

    Treska, V; Certik, B; Molacek, J

    2016-01-01

    Aortic graft infections (AGI) are serious complications of open and endovascular types of surgery with an incidence rate of 0.6-3 %. AGI are associated with 30-60 % perioperative mortality and 40-60 % morbidity rate with limb amputation rates between 10 % and 40 %. The economic cost of AGI is substantial. At the time of aortic reconstruction, almost 90 % of patients have one or more predisposing factors for AGI. The diagnosis is based on clinical symptomatology, laboratory markers, microbial cultures, and imaging modalities. The general principle of surgical treatment lies in the removal of infected graft, debridement of infected periprosthetic tissues, and vascular reconstruction by in situ or extra-anatomic bypass with long-term antibiotic therapy. The conservative treatment is used only for selected patients with endograft infection. This review summarizes the current knowledge about the incidence, predisposing factors, etiology, diagnosis, treatment options, and prevention of aortic vascular graft and endograft infections. With the growing number of endovascular procedures we can expect more cases of infected aortic endografts in patients with severe comorbidities in the near future, where the recent radical surgical approach (graft excision, debridement, and new revascularization) cannot be used. Therefore the less invasive, sophisticated and individualized treatment strategies will have to be used in search of the best therapeutic approach to each specific patient (Fig. 4, Ref. 82).

  5. Predictors of aortic growth in uncomplicated type B aortic dissection from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) database

    DEFF Research Database (Denmark)

    Kamman, Arnoud V; Brunkwall, Jan; Verhoeven, Eric L

    2017-01-01

    BACKGROUND: The high-risk patient cohort of uncomplicated type B aortic dissections (uTBADs) needs to be clarified. We compared uTBAD patients treated with best medical treatment (BMT), with and without aortic growth, from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) tri...

  6. Endovascular stent graft treatment of acute thoracic aortic transections due to blunt force trauma.

    LENUS (Irish Health Repository)

    Bjurlin, Marc A

    2012-02-01

    Endovascular stent graft treatment of acute thoracic aortic transections is an encouraging minimally invasive alternative to open surgical repair. Between 2006 and 2008, 16 patients with acute thoracic aortic transections underwent evaluation at our institution. Seven patients who were treated with an endovascular stent graft were reviewed. The mean Glasgow Coma Score was 13.0, probability of survival was .89, and median injury severity score was 32. The mean number of intensive care unit days was 7.7, mean number of ventilator support days was 5.4, and hospital length of stay was 10 days. Mean blood loss was 285 mL, and operative time was 143 minutes. Overall mortality was 14%. Procedure complications were a bleeding arteriotomy site and an endoleak. Endovascular treatment of traumatic thoracic aortic transections appears to demonstrate superior results with respect to mortality, blood loss, operative time, paraplegia, and procedure-related complications when compared with open surgical repair literature.

  7. Importance of stent-graft design for aortic arch aneurysm repair

    Directory of Open Access Journals (Sweden)

    C Singh

    2017-02-01

    Full Text Available Aneurysm of the aorta is currently treated by open surgical repair or endovascular repair. However, when the aneurysm occurs in regions between the aortic arch and proximal descending aorta, it can be a complex pathology to treat due to its intricate geometry. When complex aortic aneurysms are treated with the conventional procedures, some of the patients present with significant post-operative complications and high mortality rate. Consequently, a clinically driven hybrid innovation known as the frozen elephant trunk procedure was introduced to treat complex aortic aneurysms. Although this procedure significantly reduces mortality rate and operating time, it is still associated with complications such as endoleaks, spinal cord ischemia, renal failure and stroke. Some of these complications are consequences of a mismatch in the biomechanical behaviour of the stent-graft device and the aorta. Research on complex aneurysm repair tended to focus more on the surgical procedure than the stent-graft design. Current stent-graft devices are suitable for straight vessels. However, when used to treat aortic aneurysm with complex geometry, these devices are ineffective in restoring the normal biological and biomechanical function of the aorta. A stent-graft device with mechanical properties that are comparable with the aorta and aortic arch could possibly lead to fewer post-operative complications, thus, better outcome for patients with complex aneurysm conditions. This review highlights the influence stent-graft design has on the biomechanical properties of the aorta which in turn can contribute to complications of complex aneurysm repair. Design attributes critical for minimising postoperative biomechanical mismatch are also discussed.

  8. Potential Long-Term Complications of Endovascular Stent Grafting for Blunt Thoracic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Larry E. Miller

    2012-01-01

    Full Text Available Blunt thoracic aortic injury (BTAI is a rare, but lethal, consequence of rapid deceleration events. Most victims of BTAI die at the scene of the accident. Of those who arrive to the hospital alive, expedient aortic intervention significantly improves survival. Thoracic endovascular aortic repair (TEVAR has been accepted as the standard of care for BTAI at many centers, primarily due to the convincing evidence of lower mortality and morbidity in comparison to open surgery. However, less attention has been given to potential long-term complications of TEVAR for BTAI. This paper focuses on these complications, which include progressive aortic expansion with aging, inadequate stent graft characteristics, device durability concerns, long-term radiation exposure concerns from follow-up computed tomography scans, and the potential for (Victims of Modern Imaging Technology VOMIT.

  9. Editor's Choice - Renal complications after EVAR with suprarenal versus infrarenal fixation among all users and routine users.

    Science.gov (United States)

    Zettervall, S L; Deery, S E; Soden, P A; Shean, K; Siracuse, J J; Alef, M; Patel, V I; Schermerhorn, M L

    2017-09-01

    Previous studies comparing endografts with suprarenal and infrarenal fixation for endovascular abdominal aortic aneurysm repair (EVAR) have found conflicting results and did not account for differences in patient selection. This study aims to evaluate the differences in outcomes among surgeons who routinely use either suprarenal or infrarenal fixation, as well as all surgeons in the Vascular Study Group of New England (VSGNE). All patients undergoing EVAR in the VSGNE from 2003 to 2014 were identified. All ruptured aneurysms, repairs with concomitant procedures, and infrequently used stent grafts (80% of cases, as well as all surgeons. Multivariate regression and Cox hazard models were utilised to account for patient demographics, comorbidities, operative differences, and procedure year. This study identified 2574 patients (suprarenal, 1264; infrarenal, 1310) with 888 endografts placed by routine users (suprarenal, 409; infrarenal, 479). There were no differences in baseline comorbidities, including the estimated glomerular filtration rate, between suprarenal and infrarenal fixation, or between patients with endografts placed by routine and non-routine users. Patients treated with suprarenal endografts received more contrast than all users (102 mL vs. 100 mL, p = .01) and routine users (110 mL vs. 88 mL, p users, patients treated with suprarenal grafts had higher rates of creatinine increase >.5 mg/dL (3.7% vs. 2.0%, p = .01), length of stay >2 days (27% vs. 19%, p users, suprarenal fixation was also associated with higher rates of renal dysfunction (3.7% vs. 1.3%, p = .02; OR 2.9; 95% CI 1.1-7.8). Despite potential differences in patient selection, endografts with suprarenal fixation among all users and routine users were associated with higher rates of renal deterioration and longer length of hospital stay. Longer-term data are needed to determine the duration and severity of renal function decline and to identify potential benefits of decreased

  10. Open Versus Endovascular Stent Graft Repair of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Firwana, Belal; Ferwana, Mazen; Hasan, Rim

    2014-01-01

    We performed an analysis to assess the need for conducting additional randomized controlled trials (RCTs) comparing open and endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Trial sequential analysis (TSA) is a statistical methodology that can calculate the required inform...

  11. Endovascular repair of early rupture of Dacron aortic graft--two case reports.

    LENUS (Irish Health Repository)

    Sultan, Sherif

    2005-01-01

    Complications after open aortic surgery pose a challenge both to the vascular surgeon and the patient because of aging population, widespread use of cardiac revascularization, and improved survival after aortic surgery. The perioperative mortality rate for redo elective aortic surgery ranges from 5% to 29% and increases to 70-100% in emergency situation. Endovascular treatment of the postaortic open surgery (PAOS) patient has fewer complications and a lower mortality rate in comparison with redo open surgical repair. Two cases of ruptured abdominal aortic aneurysm (AAA) were managed with the conventional open surgical repair. Subsequently, spiral contrast computer tomography scans showed reperfusion of the AAA sac remnant mimicking a type III endoleak. These graft-related complications presented as vascular emergencies, and in both cases endovascular aneurysm repair (EVAR) procedure was performed successfully by aortouniiliac (AUI) stent graft and femorofemoral crossover bypass. These 2 patients add further merit to the cases reported in the English literature. This highlights the crucial importance of endovascular grafts in the management of such complex vascular problems.

  12. Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft

    International Nuclear Information System (INIS)

    Saratzis, N.; Saratzis, Athanasios; Melas, N.; Ginis, G.; Lioupis, A.; Lykopoulos, D.; Lazaridis, J.; Kiskinis, Dimitrios

    2007-01-01

    Objective. To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). Methods. Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 refused open repair) from January 2003 to July 2005. Results. Complete aneurysm exclusion was feasible in all subjects (100% technical success). The median follow-up was 18 months (range 8-40 months). A single stent-graft was used in 6 cases. The deployment of a second stent-graft was required in the remaining 17 patients. All endografts were attached proximally, beyond the left subclavian artery, leaving the aortic arch branches intact. No procedure-related deaths have occurred. A distal type I endoleak was detected in 2 cases on the 1 month follow-up CT scan, and was repaired with reintervention and deployment of an extension graft. A nonfatal acute myocardial infarction occurred in 1 patient in the sixth postoperative month. Graft migration, graft infection, paraplegia, cerebral or distal embolization, renal impairment or any other major complications were not observed. Conclusion. The treatment of DTAAs using the EndoFit stent-graft is technically feasible. Mid-term results in this series are promising

  13. The management of impending myocardial infarction using coronary artery by-pass grafting and an intra-aortic balloon pump.

    Science.gov (United States)

    Harris, P L; Woollard, K; Bartoli, A; Makey, A R

    1980-01-01

    Of 33 patients with impending myocardial infarction 25 were treated using a combination of coronary artery by-pass grafting and intra-aortic balloon pumping. Eight patients were treated with coronary artery by-pass grafting alone. Twenty-two of the 25 patients who were treated with the combined technique made a full recovery. Three patients sustained definite myocardial infarctions and one of these died. Five of the 8 patients treated by grafting alone suffered infarction and of these 3 died. The value of intra-aortic balloon pumping in combination with coronary artery by-pass grafting in the management of impending myocardial infarction is discussed.

  14. The implantation of separating aortic stent-graft into the canine thoracic aorta: an experimental study

    International Nuclear Information System (INIS)

    Xia Jinguo; Shi Haibin; Yang Zhengqiang; Li Chao; Liu Sheng; Zu Qingquan; Li Linsun

    2011-01-01

    Objective: to assess the technical feasibility of implanting separating stent-graft into the canine thoracic aorta and to study its biocompatibility. Methods: Twelve adult dogs were randomly and equally divided into three groups. The right femoral artery was cut open, through which the separating stent-graft was inserted and deployed in the canine thoracic aorta, with the proximal end of the graft being quite close to the origin of the left subclavian artery. the technical feasibility of the deployment process was assessed. Angiography was performed at 4, 8 and 12 weeks after stent-graft placement to evaluate the position and patency of the stent-graft. Then the dogs were sacrificed and the specimens were collected for pathologic study. Both gross and microscopic examinations were made to evaluate the fixation of the stent-graft with the vessel wall, the endothelialization of stent-graft surface and the pathologic changes of the vascular wall. Results: A total of ten separating stent-grafts were successfully deployed in the canine thoracic aorta, no migration or deformation occurred. One dog died of massive bleeding due to the rupture of the right femoral artery which occurred when the delivery system containing the inner bare stent was inserted through the right femoral artery. Death occurred in another dog as a result of the ascending aorta rupture caused by the migration of outer-layer stent-graft. Angiography was conducted at 4, 8 and 12 weeks after stent-graft placement. No migration, deformation, rupture or stenosis of the implanted stent-grafts were observed. The formation of intima on the inner surface of the bare stent appeared at 4 weeks, which became more and more obvious with the time passing, and at 12 weeks complete endothelialization of stent-graft surface was observed. Conclusion: Technically, it is feasible to deploy the separating aortic stent-graft into the canine thoracic aorta. Moreover, the separating aortic stent-graft carries excellent

  15. Systemic thioridazine in combination with dicloxacillin against early aortic graft infections caused by Staphylococcus aureus in a porcine model

    DEFF Research Database (Denmark)

    Stenger, Michael; Behr-Rasmussen, Carsten; Klein, Kasper

    2017-01-01

    INTRODUCTION: Conservative treatment solutions against aortic prosthetic vascular graft infection (APVGI) for inoperable patients are limited. The combination of antibiotics with antibacterial helper compounds, such as the neuroleptic drug thioridazine (TDZ), should be explored. AIM: To investigate...

  16. A 10-year institutional experience with open branched graft reconstruction of aortic aneurysms in connective tissue disorders versus degenerative disease.

    Science.gov (United States)

    Hicks, Caitlin W; Lue, Jennifer; Glebova, Natalia O; Ehlert, Bryan A; Black, James H

    2017-11-01

    Aortic reconstruction for complex thoracoabdominal aortic aneurysms (TAAAs) can be challenging, especially in patients with connective tissue disorders (CTDs) in whom tissue fragility is a major concern. Branched graft reconstruction is a more complex operation compared with inclusion patch repair of the aorta but is frequently necessary in patients with CTDs or other pathologies because of anatomic reasons. We describe our institutional experience with open branched graft reconstruction of aortic aneurysms and compare outcomes for patients with CTDs vs degenerative pathologies. We retrospectively analyzed all patients undergoing open aortic reconstruction using branched grafts at our institution between July 2006 and December 2015. Postoperative outcomes, including perioperative morbidity and mortality, midterm graft patency, and the development of new aneurysms, were compared for patients with CTD vs degenerative disease. During the 10-year study period, 137 patients (CTD, 29; degenerative, 108) underwent aortic repair with branched graft reconstruction. CTD patients were significantly younger (39 ± 1.9 vs 68 ± 1.0 years; P disease, coronary artery disease; P degenerative disease. Perioperative mortality (CTD: 10% [n = 3] vs degenerative: 6% [n = 6]; P = .40) and any complication (62% vs 55%; P = .47) were similar between groups. At a median follow-up time of 14.5 months (interquartile range: 6.5, 43.9 months), CTD patients were more likely to develop both new aortic (21%) and nonaortic (14%) aneurysms compared with the degenerative group (7% and 4% for aortic and nonaortic aneurysms, respectively; P = .02). Loss of branch graft patency occurred in 0 of 99 grafts (0%) in CTD patients and in 13 of 167 grafts (7.8%) in degenerative disease patients (P = .005). Loss of branch graft patency occurred most commonly in left renal artery bypass grafts (77%) and was clinically asymptomatic (creatinine: 1.77 ± 0.13 mg/dL currently vs 1.41 ± 0

  17. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2012-02-01

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  18. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2010-11-11

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  19. Multidisciplinary Treatment Approach for Prosthetic Vascular Graft Infection in the Thoracic Aortic Area

    Science.gov (United States)

    Watanabe, Yoshinori

    2015-01-01

    Prosthetic vascular graft infection in the thoracic aortic area is a rare but serious complication. Adequate management of the complication is essential to increase the chance of success of open surgery. While surgical site infection is suggested as the root cause of the complication, it is also related to decreased host tolerance, especially as found in elderly patients. The handling of prosthetic vascular graft infection has been widely discussed to date. This paper mainly provides a summary of literature reports published within the past 5 years to discuss issues related to multidisciplinary treatment approaches, including surgical site infection, timing of onset, diagnostic methods, causative pathogens, auxiliary diagnostic methods, antibiotic treatment, anti-infective structures of vascular prostheses, surgical treatment, treatment strategy against infectious aortic aneurysms, future surgical treatment, postoperative systemic therapy, and antimicrobial stewardship. A thorough understanding of these issues will enable us to prevent prosthetic vascular graft infection in the thoracic aortic area as far as possible. In the event of its occurrence, the early introduction of appropriate treatment is expected to cure the disease without worsening of the underlying pathological condition. PMID:26356686

  20. Early and midterm outcomes of open stent-graft treatment for distal aortic arch aneurysm

    International Nuclear Information System (INIS)

    Yamada, Kazunori; Mochizuki, Takaaki; Tsubota, Hideki; Funamoto, Masaki

    2008-01-01

    The aim of this study was to investigate early and late outcomes for open stent-graft treatment, which was introduced as a less-invasive technique for thoracic aortic aneurysm of the distal arch, and to clarify the validity of and indications for this treatment. We retrospectively investigated 38 patients with thoracic aortic aneurysm of the distal arch who underwent open stent-graft placement at our hospital between June 2000 and September 2006. Five patients died in hospital (hospital mortality 13.2%). Age at the time of surgery and onset of postoperative paraplegia were identified as risk factors. Four patients (10.5%) had postoperative paraplegia, but no significant risk factors were seen. The size of the aneurysm was clearly reduced in 18 of the 25 patients (75.8%), in whom computed tomography was performed after discharge, and late outcomes were good. Mural thrombus thickness on the stent landing zone of <4 mm was a predictor for aneurysm shrinkage. Seven patients died during the late period, and the 5-year survival rate among hospital survivors was 80.1%. Early outcomes for open stent-graft are not necessarily good, and late survival is also not excellent. Open stent-graft thus cannot be regarded as an ideal technique for all patients with distal aortic arch aneurysm. However, after aneurysm shrinkage was confirmed during the early period, late outcomes were good. Absence of thick mural thrombus on the stent landing zone may represent a good indication for open stent-graft surgery. (author)

  1. Endovascular graft exclusion in treating thoracic aortic dissection: a report of 25 cases

    International Nuclear Information System (INIS)

    Chen Wei; Yang Jianyong; Zhuang Wenquan; Guo Wenbo; Li Heping; Zhong Lizhen; Huang Qiuping

    2003-01-01

    Objective: To evaluate the usefulness and efficacy of endovascular graft exclusion (EVGE) in treating thoracic aortic dissection (TAD). Methods: Twenty-five cases of TAD, including 24 cases of Standford B and 1 case of A, were treated by EVGE. The clinical outcome and morphological changes of the lesions were analyzed during a 2-20 months' follow-up. Results: Procedures were technically successful in all 25 cases, while a total of 28 stent-grafts were deployed (3 cases with 2 stent-grafts in each). Complete disappearance of the false lumen or remarkable decrease of the endoleak was noted on the angiograms after stent placement. No severe procedure-related complication was observed, and thrombosis of the false lumen was noted during the follow-up. Conclusion: EVGE is effective and reliable in treating TAD, especially for patients with sub-acute or chronic courses

  2. Endovascular aortic graft infection resulting in retroperitoneal abscess: report of a case

    Directory of Open Access Journals (Sweden)

    Salvatore Di Somma

    2010-06-01

    Full Text Available Infection is a rare complication of aortoiliac endovascular procedures, with an incidence inferior to 0.5%, and it may result in a retroperitoneal abscess potentially evolving to sepsis and gastrointestinal bleeding. In more than 50% of cases endovascular aortoiliac prosthetic grafts infection occur months or years after the procedure. The growing number of endovascular procedures, and as the actually midterm follow up in most cases, septic sequelae will no doubt continue to occur with increased frequency and may represent an emerging problem in the ED for the emergency physician. Endovascular graft infection begins with unspecific clinical manifestations. An high index of suspicion in any patient with an aortic stent graft presenting prolonged or recurrent fever and or abdominal or back pain and a low threshold for obtaining CT scan should increase the clinician’s ability to make a timely diagnosis in the ED setting.

  3. Concepts to optimize stent-grafting of abdominal aortic aneurysms based on results of experimental studies

    International Nuclear Information System (INIS)

    Chavan, A.; Kirchhoff, T.; Baus, S.; Galanski, M.; Pichlmaier, M.

    2001-01-01

    Purpose. In the endoluminal therapy of abdominal aortic aneurysms, a short proximal aneurysm neck, endoleaks and the large size and stiffness of the introducer systems are responsible for many of the complications and sub-optimal outcomes. The purpose of the present review article is to to suggest strategies to minimize these complications based on the results of experimental studies in animals. Material and methods. After implanting various types of stents across the renal artery origins, the functional and morphological changes in the kidneys and renal vessels were studied by various authors. In order to prevent progressive widening of the proximal aneurysmal neck and graft dislocation, Sonesson et al. performed a laparoscopic banding around the proximal neck in pigs. To study the effects of endoleaks, Marty, Schurink and Pitton carried out pressure measurements in experimental aneurysms with and without endoleaks. Sakaguchi and Pavcnik developed the 'Twin-tube endografts' (TTEG) and the 'Bifurcated drum occluder endografts' (BDOEG) and tested them in dogs. Results. Up to 3 months after suprarenal stent placement, Chavan et al. detected no significant fall in the mean inulin clearance in sheep (140±46 ml/min before, 137±58 ml/min after). Nasim et al. and Malina et al. reported similar observations with respect to renal function. Suprarenal fixation may result in isolated thrombotic occlusions of the renal arteries and microinfarcts in the kidneys. Mean aortic diameters at the level of banding were significantly smaller in the animals with aortic banding as opposed to those in the control group without banding (8 mm vs 11 mm, p=0.004). The banding caused a secure proximal fixation of the stent-graft. Persistent endoleaks resulted in significantly higher intraaneurysmal pressures. Although the TTEG and the BDOEG stent-grafts required smaller sheaths, occlusions were observed in 8% (TTEG) and 60% (BDOEG) of the graft limbs. (orig.) [de

  4. Computational Fluid Dynamics: Hemodynamic Changes in Abdominal Aortic Aneurysm After Stent-Graft Implantation

    International Nuclear Information System (INIS)

    Frauenfelder, Thomas; Lotfey, Mourad; Boehm, Thomas; Wildermuth, Simon

    2006-01-01

    The aim of this study was to demonstrate quantitatively and qualitatively the hemodynamic changes in abdominal aortic aneurysms (AAA) after stent-graft placement based on multidetector CT angiography (MDCT-A) datasets using the possibilities of computational fluid dynamics (CFD). Eleven patients with AAA and one patient with left-side common iliac aneurysm undergoing MDCT-A before and after stent-graft implantation were included. Based on the CT datasets, three-dimensional grid-based models of AAA were built. The minimal size of tetrahedrons was determined for grid-independence simulation. The CFD program was validated by comparing the calculated flow with an experimentally generated flow in an identical, anatomically correct silicon model of an AAA. Based on the results, pulsatile flow was simulated. A laminar, incompressible flow-based inlet condition, zero traction-force outlet boundary, and a no-slip wall boundary condition was applied. The measured flow volume and visualized flow pattern, wall pressure, and wall shear stress before and after stent-graft implantation were compared. The experimentally and numerically generated streamlines are highly congruent. After stenting, the simulation shows a reduction of wall pressure and wall shear stress and a more equal flow through both external iliac arteries after stenting. The postimplantation flow pattern is characterized by a reduction of turbulences. New areas of high pressure and shear stress appear at the stent bifurcation and docking area. CFD is a versatile and noninvasive tool to demonstrate changes of flow rate and flow pattern caused by stent-graft implantation. The desired effect and possible complications of a stent-graft implantation can be visualized. CFD is a highly promising technique and improves our understanding of the local structural and fluid dynamic conditions for abdominal aortic stent placement

  5. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  6. Detection of thoracic aortic prosthetic graft infection with 18F-fluorodeoxyglucose positron emission tomography/computed tomography.

    Science.gov (United States)

    Tokuda, Yoshiyuki; Oshima, Hideki; Araki, Yoshimori; Narita, Yuji; Mutsuga, Masato; Kato, Katsuhiko; Usui, Akihiko

    2013-06-01

    To investigate the diagnostic value of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in detecting thoracic aortic prosthetic graft infection. Nine patients with clinically suspected thoracic aortic graft infection underwent FDG-PET/CT scanning. In these patients, the diagnoses could not be confirmed using conventional modalities. The patients' clinical courses were retrospectively reviewed. On the basis of surgical, microbiological and clinical follow-up findings, the aortic grafts were considered infected in 4 patients and not infected in 5. All 4 patients with graft infection (root: 2 cases, arch: 1 case and descending: 1 case) eventually underwent in situ re-replacement. Two of the 4 patients also had abdominal grafts; however, only the thoracic grafts were replaced because uptake was low around the abdominal grafts. The maximal standardized uptake value (SUVmax) in the perigraft area was higher in the infected group than in the non-infected group (11.4 ± 4.5 vs 6.9 ± 6.4), although the difference was not statistically significant. According to the receiver operating characteristic analysis, SUVmax >8 appeared to be the cut-off value in distinguishing the two groups (sensitivity: 1.0 and specificity: 0.8). FDG-PET/CT is useful for confirming the presence of graft infection by detecting high uptake around grafts and excluding other causes of inflammation. An SUVmax value greater than 8 around a graft suggests the presence of graft infection. In addition, FDG-PET/CT can be used to clarify the precise extent of infection. This is especially useful if multiple separated prosthetic grafts have been implanted.

  7. Aortic root surgery in Marfan syndrome: Bentall procedure with the composite mechanical valved conduit versus aortic valve reimplantation with Valsalva graft.

    Science.gov (United States)

    Nardi, Paolo; Pellegrino, Antonio; Versaci, Francesco; Mantione, Ludmilla; Polisca, Patrizio; Iorio, Fiore S; Chiariello, Luigi

    2010-09-01

    The aim of the study is to compare mid-term results of Bentall aortic root replacement with composite mechanical valved conduit and aortic valve reimplantation procedure using the Valsalva graft for the treatment of aortic root aneurysm in patients with Marfan syndrome. We retrospectively compared data of 23 patients (mean age 38 + or - 14 years) who had undergone the Bentall procedure (group B) to those of 24 patients (mean age 36 + or - 12 years) who had undergone aortic valve reimplantation (group R) during a 14-year period. Follow-up (mean duration 65 + or - 44 months) was 100% complete. There were no operative deaths in either group. In group B, as compared with group R, preoperative aortic insufficiency (3.2 + or - 1.1/4 vs. 1.7 + or - 1.4/4, P Marfan patients, the Bentall procedure is associated with excellent mid-term outcome. The reimplantation technique, adopted for less dilated aortas, provides similarly satisfactory results. The Valsalva graft seems, with time, to allow a stable aortic valve function.

  8. Brief report: biomarkers of aortic vascular prosthetic graft infection in a porcine model with Staphylococcus aureus

    DEFF Research Database (Denmark)

    Langerhuus, S. N.; Tønnesen, E. K.; Jensen, K. H.

    2010-01-01

    Aortic vascular prosthetic graft infection (AVPGI) with Staphylococcus aureus is a feared post-operative complication. This study was conducted to evaluate the clinical signs and potential biomarkers of infection in a porcine AVPGI model. The biomarkers evaluated were: C-reactive protein (CRP......), fibrinogen, white blood cells (WBC), major histocompatibility complex II (MHC II) density, lymphocyte CD4:CD8 ratio and tumour necrosis factor-alpha (TNF-α) in vitro responsiveness. Sixteen pigs were included in the study, and randomly assigned into four groups (n = 4): “SHAM” pigs had their infra...

  9. Systemic thioridazine in combination with dicloxacillin against early aortic graft infections caused by Staphylococcus aureus in a porcine model: In vivo results do not reproduce the in vitro synergistic activity.

    Directory of Open Access Journals (Sweden)

    Michael Stenger

    Full Text Available Conservative treatment solutions against aortic prosthetic vascular graft infection (APVGI for inoperable patients are limited. The combination of antibiotics with antibacterial helper compounds, such as the neuroleptic drug thioridazine (TDZ, should be explored.To investigate the efficacy of conservative systemic treatment with dicloxacillin (DCX in combination with TDZ (DCX+TDZ, compared to DCX alone, against early APVGI caused by methicillin-sensitive Staphylococcus aureus (MSSA in a porcine model.The synergism of DCX+TDZ against MSSA was initially assessed in vitro by viability assay. Thereafter, thirty-two pigs had polyester grafts implanted in the infrarenal aorta, followed by inoculation with 106 CFU of MSSA, and were randomly administered oral systemic treatment with either 1 DCX or 2 DCX+TDZ. Treatment was initiated one week postoperatively and continued for a further 21 days. Weight, temperature, and blood samples were collected at predefined intervals. By termination, bacterial quantities from the graft surface, graft material, and perigraft tissue were obtained.Despite in vitro synergism, the porcine experiment revealed no statistical differences for bacteriological endpoints between the two treatment groups, and none of the treatments eradicated the APVGI. Accordingly, the mixed model analyses of weight, temperature, and blood samples revealed no statistical differences.Conservative systemic treatment with DCX+TDZ did not reproduce in vitro results against APVGI caused by MSSA in this porcine model. However, unexpected severe adverse effects related to the planned dose of TDZ required a considerable reduction to the administered dose of TDZ, which may have compromised the results.

  10. Acute Symptomatic Abdominal Aortic Aneurysm Secondary to Endovascular Stent Graft Associated Type II Endoleak

    Directory of Open Access Journals (Sweden)

    Karen Ka Leung Chan

    2006-07-01

    Full Text Available Endovascular abdominal aneurysm repair (EVAR is popular because of its low invasiveness and feasibility for high-risk patients. Endoleak is common after EVAR and is characterized by blood flow within the aneurysm sac but outside the stent graft. Type II or collateral endoleak commonly results from retrograde filling of the aneurysm from collateral visceral vessels, lumbar, inferior mesenteric, accessory renal or sacral arteries. Collateral leaks are generally thought to be benign and over half of the early leaks will seal spontaneously. Sporadically, collateral endoleak could lead to aneurysm sac pressurization and place the patient at ongoing risk of rupture. Herein, we report an uncommon case of early post-stent graft placement symptomatic abdominal aortic aneurysm associated with type II endoleak.

  11. Thoracic Stent Graft Implantation for Aortic Coarctation with Patent Ductus Arteriosus via Retroperitoneal Iliac Approach in the Presence of Small Sized Femoral Artery

    Directory of Open Access Journals (Sweden)

    Ozge Korkmaz

    2016-01-01

    Full Text Available Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach.

  12. Short-term curative effect of endovascular stent-graft treatment for aortic diseases in China: a systematic review.

    Directory of Open Access Journals (Sweden)

    Siwen Wang

    Full Text Available INTRODUCTION: We analyzed the short-term efficacy of endovascular treatment for aortic diseases by summarizing all available published data on endovascular stent-graft treatment for abdominal aortic aneurysm (AAA, thoracic aortic aneurysm (TAA, type A aortic dissection (type A AD and type B aortic dissection (type B AD in China. METHODS: We performed a systematic analysis of 935 published series on retrograde endovascular treatment for aortic diseases in China from January 1996 to November 2010. Based on the inclusion criteria, 159 studies, involving a total of 5531 patients, were included. RESULTS: There were no significant differences in procedural success among the studies (P>0.05. The rates of overall neurologic complications and stroke were significantly different in all two-group comparisons (P0.05. A significant difference was noted between the 30-day mortality rate of the type A AD patients and the AAA or type B AD patients (P<0.05. CONCLUSION: Endovascular stent-graft is a feasible and safe treatment for aortic diseases, with high procedural success and low incidences of post-procedural complications and short-term mortality. Endovascular treatment for AAA and type B AD is more efficient than for type A AD and TAA.

  13. Endovascular Repair of Acute Symptomatic Pararenal Aortic Aneurysm With Three Chimney and One Periscope Graft for Complete Visceral Artery Revascularization

    International Nuclear Information System (INIS)

    Brechtel, Klaus; Ketelsen, Dominik; Endisch, Andrea; Heller, Stephan; Heuschmid, Martin; Stock, Ulrich A.; Kalender, Guenay

    2012-01-01

    PurposeTo describe a modified endovascular technique for complete revascularization of visceral and renal arteries in symptomatic pararenal aortic aneurysm (PRAA).TechniqueArterial access was surgically established in both common femoral arteries (CFAs) and the left subclavian artery (LSA). Revascularization of the left renal artery, the celiac trunk, and the superior mesenteric artery was performed through one single sheath via the LSA. Suitable covered stents were put in the aortic branches but not deployed. The right renal artery was accessed over the left CFA. Due to the longitudinal extension of the presented aneurysm two stent-grafts were introduced via the right CFA. After deploying the aortic stent-grafts, all covered stents in the side branches were deployed consecutively with a minimum overlap of 5 mm over the cranial and caudal stent-graft edges. Simultaneous ballooning was performed to fully expand all stent-grafts and warranty patency. Conclusion: This is the first report in the literature of chimney grafting in PRAA for complete revascularization of visceral and renal branches by using more than two covered stents introduced from one side through one single sheath. However this technique is modified, it should be used only in bailout situations when branched stent-grafts are not available and/or surgery is not suitable.

  14. Aortic rupture during aortoplasty in Takayasu arteritis – A rare complication: Case report and review of literature

    Directory of Open Access Journals (Sweden)

    Vimal Mehta

    2014-05-01

    Full Text Available Balloon angioplasty of the stenosed aorta is usually a relatively simple, yet potentially a catastrophic procedure. Aortic rupture during aortoplasty, though uncommon, carries a high mortality. We report case of a 39-year-old female with aortoarteritis with multiple arterial stenoses whose infra-renal abdominal aorta ruptured during balloon dilatation of the stent deployed in that segment. The site of aortic rupture was temporarily occluded by low-pressure inflation of the same balloon and then was sealed using a stent-graft introduced by contra-lateral femoral arterial access.

  15. Hybrid Repair of Complex Thoracic Aortic Arch Pathology: Long-Term Outcomes of Extra-anatomic Bypass Grafting of the Supra-aortic Trunk

    International Nuclear Information System (INIS)

    Lotfi, S.; Clough, R. E.; Ali, T.; Salter, R.; Young, C. P.; Bell, R.; Modarai, B.; Taylor, P.

    2013-01-01

    Hybrid repair constitutes supra-aortic debranching before thoracic endovascular aortic repair (TEVAR). It offers improved short-term outcome compared with open surgery; however, longer-term studies are required to assess patient outcomes and patency of the extra-anatomic bypass grafts. A prospectively maintained database of 380 elective and urgent patients who had undergone TEVAR (1997–2011) was analyzed retrospectively. Fifty-one patients (34 males; 17 females) underwent hybrid repair. Median age was 71 (range, 18–90) years with mean follow-up of 15 (range, 0–61) months. Perioperative complications included death: 10 % (5/51), stroke: 12 % (6/51), paraplegia: 6 % (3/51), endoleak: 16 % (8/51), rupture: 4 % (2/51), upper-limb ischemia: 2 % (1/51), bypass graft occlusion: 4 % (2/51), and cardiopulmonary complications in 14 % (7/51). Three patients (6 %) required emergency intervention for retrograde dissection: (2 aortic root repairs; 2 innominate stents). Early reintervention was performed for type 1 endoleak in two patients (2 proximal cuff extensions). One patient underwent innominate stenting and revision of their bypass for symptomatic restenosis. At 48 months, survival was 73 %. Endoleak was detected in three (6 %) patients (type 1 = 2; type 2 = 1) requiring debranching with proximal stent graft (n = 2) and proximal extension cuff (n = 1). One patient had a fatal rupture of a mycotic aneurysm and two arch aneurysms expanded. No bypass graft occluded after the perioperative period. Hybrid operations to treat aortic arch disease can be performed with results comparable to open surgery. The longer-term outcomes demonstrate low rates of reintervention and high rates of graft patency.

  16. Hybrid Repair of Complex Thoracic Aortic Arch Pathology: Long-Term Outcomes of Extra-anatomic Bypass Grafting of the Supra-aortic Trunk

    Energy Technology Data Exchange (ETDEWEB)

    Lotfi, S., E-mail: shamim.lotfi@kcl.ac.uk; Clough, R. E.; Ali, T. [Guy' s and St. Thomas' NHS Trust, Vascular Surgery (United Kingdom); Salter, R. [Guy' s and St. Thomas' NHS Trust, Interventional Radiology (United Kingdom); Young, C. P. [Guy' s and St. Thomas' NHS Trust, Cardiac Surgery (United Kingdom); Bell, R.; Modarai, B.; Taylor, P., E-mail: peter.taylor@gstt.nhs.uk [Guy' s and St. Thomas' NHS Trust, Vascular Surgery (United Kingdom)

    2013-02-15

    Hybrid repair constitutes supra-aortic debranching before thoracic endovascular aortic repair (TEVAR). It offers improved short-term outcome compared with open surgery; however, longer-term studies are required to assess patient outcomes and patency of the extra-anatomic bypass grafts. A prospectively maintained database of 380 elective and urgent patients who had undergone TEVAR (1997-2011) was analyzed retrospectively. Fifty-one patients (34 males; 17 females) underwent hybrid repair. Median age was 71 (range, 18-90) years with mean follow-up of 15 (range, 0-61) months. Perioperative complications included death: 10 % (5/51), stroke: 12 % (6/51), paraplegia: 6 % (3/51), endoleak: 16 % (8/51), rupture: 4 % (2/51), upper-limb ischemia: 2 % (1/51), bypass graft occlusion: 4 % (2/51), and cardiopulmonary complications in 14 % (7/51). Three patients (6 %) required emergency intervention for retrograde dissection: (2 aortic root repairs; 2 innominate stents). Early reintervention was performed for type 1 endoleak in two patients (2 proximal cuff extensions). One patient underwent innominate stenting and revision of their bypass for symptomatic restenosis. At 48 months, survival was 73 %. Endoleak was detected in three (6 %) patients (type 1 = 2; type 2 = 1) requiring debranching with proximal stent graft (n = 2) and proximal extension cuff (n = 1). One patient had a fatal rupture of a mycotic aneurysm and two arch aneurysms expanded. No bypass graft occluded after the perioperative period. Hybrid operations to treat aortic arch disease can be performed with results comparable to open surgery. The longer-term outcomes demonstrate low rates of reintervention and high rates of graft patency.

  17. Reimplantation valve-sparing aortic root replacement with the Valsalva graft: what have we learnt after 100 cases?

    Science.gov (United States)

    Settepani, Fabrizio; Bergonzini, Marcello; Barbone, Alessandro; Citterio, Enrico; Basciu, Alessio; Ornaghi, Diego; Gallotti, Roberto; Tarelli, Giuseppe

    2009-07-01

    Reimplantation valve-sparing aortic root replacement has been increasingly performed with improving perioperative and mid-term results. The success of this operation primarily depends on preserving the highly sophisticated dynamic function of the aortic valve by recreating an anatomical three-dimensional configuration similar to the normal aortic root, thus minimizing the mechanical stress and strain on the cusps. Over the years several techniques have been proposed to reproduce the sinuses of Valsalva. We reviewed our experience with aortic valve reimplantation by means of a modified Dacron graft that incorporates sinuses of Valsalva, in a series of 100 consecutive patients. During a 60-month period, 100 patients with aortic root aneurysm underwent aortic valve reimplantation using the Gelweave Valsalva prosthesis. There were 74 males and the mean age was 60+/-12 years (range 28-83 years). Five patients had the Marfan's syndrome, 15 had a bicuspid aortic valve. Cusp repair was performed in five patients. The mean follow-up time was 28.6 months (range 1-60). Transesophageal echocardiogram was performed at the end of each procedure to assess the aortic valve in terms of competence, dynamic motion and level of coaptation within the graft. There was one hospital death and two late deaths. Overall survival at 60 months was 91.7+/-5.1%. Five patients developed severe aortic incompetence (AI) during follow-up requiring aortic valve replacement (AVR). The 60 months freedom from re-operation due to AI was 90.9+/-4.4%. One patient had moderate AI at latest echocardiographic study. The 60 months freedom from AI>2+ was 91.6+/-7.9%. Cox regression identified cusp's repair as independent risk factor (P=0.001) for late reimplantation failure (AVR or AI>2+). There were no episodes of endocarditis and the majority of the patients (88%) were in New York Heart Association functional class I. The aortic valve reimplantation with the Gelweave Valsalva prosthesis provided satisfactory

  18. A current systematic evaluation and meta-analysis of chimney graft technology in aortic arch diseases.

    Science.gov (United States)

    Ahmad, Wael; Mylonas, Spyridon; Majd, Payman; Brunkwall, Jan Sigge

    2017-11-01

    The aim of this study was to provide a review of the literature on the use of chimney graft (CG) technique in treating arterial diseases of the aortic arch and to extrapolate conclusions by summarizing the reported outcomes in a meta-analysis. An extensive electronic search was made using PubMed/MEDLINE, Science Direct Databases, and the Cochrane Library. Included in this meta-analysis were all papers published up to February 2016 on endovascular chimney technique in the arch vessels with or without adjunct extra-anatomic debranching, in any language, providing data about at least one of the essential outcomes: early and late type I endoleak, 30-day mortality rate, development of perioperative stroke, patency, and retrograde aortic dissection. Of the 478 reports yielded by the electronic search, a total of 11 publications (on 373 patients and 387 CGs) fulfilled the inclusion criteria and were included in this study. The overall estimated proportion of technical success was 91.3% (95% confidence interval [CI], 87.4%-94.0%). Of the 373 patients, 26 (7%) experienced a type Ia endoleak in the perioperative period. The overall estimated proportion of early type Ia endoleak was 9.4% (95% CI, 6.5%-13.4%). Among the 10 studies that provided data, a retrograde type A dissection was observed in 2 of 351 patients, resulting in an overall estimated proportion of 1.8% (95% CI, 0.8%-4.0%). The pooled 30-day mortality rate was 7.9% (95% CI, 4.6%-13.2%). The pooled estimation for reintervention was 10.6% (95% CI, 5%-21%); for major stroke, 2.6% (95% CI, 1.3%-5.0%); for early patency, 97.9% (95% CI, 95.8%-99%); and for late patency, 92.9% (95% CI, 87.3%-96%). Treatment of aortic diseases involving the aortic arch poses a great challenge. The CG technique has been applied as an alternative treatment option. This meta-analysis shows that endovascular repair of aortic arch disease using a CG technique in the aortic arch vessels is technically feasible and effective but not without

  19. Resolved Abdominal Aortic Aneurysms Following Stent Graft Treatment: A Report of Five Cases

    International Nuclear Information System (INIS)

    Rimon, Uri; Garniek, Alexander; Golan, Gil; Bensaid, Paul; Galili, Yair; Schneiderman, Jacob; Morag, Benyamina

    2004-01-01

    Complete aneurysm resolution is the hallmark of successful endoluminal stent-graft treatment. We describe 5 patients in whom an abdominal aortic aneurysm (AAA) disappeared completely at mid-term follow-up after endovascular stent-graft placement. We reviewed 45 patients (43 men and 2 women) who underwent AAA repair using an endovascular technique, from April 1997 to December 2001. Mean AAA diameter was 58.3 mm. On 48-month follow-up, 12 aneurysms had not changed in size, 4 had grown, 16 had shrunk, and 5 had resolved completely. We describe these 5 patients in detail. The 5 patients were all men, mean age 68 years; their mean aneurysmal sac diameter was 54 mm. The only common finding in all of them was patency of lumbar and inferior mesenteric arteries at pre-procedure evaluation as well as at follow-up. Mean time to complete resolution was 18 months. No major complications were encountered. AAA may resolve completely after endovascular stent-graft implantation. Patent side branches may perhaps contribute to AAA disappearance by antegrade flow. A larger patient population should be reviewed, however, before any statistical conclusion can be drawn

  20. Cryopreserved Human Allografts for the Reconstruction of Aortic and Peripheral Prosthetic Graft Infection.

    Science.gov (United States)

    Bossi, Matteo; Tozzi, Matteo; Franchin, Marco; Ferraro, Stefania; Rivolta, Nicola; Ferrario, Massimo; Guttadauro, Chiara; Castelli, Patrizio; Piffaretti, Gabriele

    2017-12-25

    Background : This study aimed to present cases with cryopreserved human allografts (CHAs) for vascular reconstruction in both aortic and peripheral infected prosthetic grafts. Materials and Methods : This is a single center, observational descriptive study with retrospective analysis. In all cases, the infected prosthetic graft material was completely removed. At discharge, patients were administered anticoagulants. Follow-up examinations included clinical visits, echo-color-Doppler ultrasounds, or computed tomography angiography within 30 days and at 3, 6, and 12 months after the treatment, and then twice per year. Results : We treated 21 patients (90% men, n=19) with the mean age of 71±12 years and mean interval between the initial operation and replacement with CHA of 30 months [range, 1-216; interquartile range (IQR), 2-36]. In-hospital mortality was 14% (n=3); no CHA-related complication led to death. Limb salvage was 100%. No patient was lost at the median follow-up of 14 months (range, 2-61; IQR, 6-39). No rupture, aneurysmal degeneration, or re-infection occurred. Estimated freedom from CHA-related adverse events (95% confidence interval, 43-63) was 95% at 3 years. Conclusion : In our experience, CHAs are a viable option for prosthetic graft infections and provide satisfactory clinical results and favorable stability because of a very low rate of CHA-related adverse events during follow-up.

  1. Development of an abdominal aortic aneurysm model for stent-graft insertion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyung; Lee, Jong Heon; Shin, Dong Ik; Sung, Kyu Bo; Ko, Gi Young; Lim, Jin Oh [College of Medicine, Univ. of Ulsan, Seoul (Korea, Republic of); Kim, Si Hoon [S and G Biotech Research Institute, Seoul (Korea, Republic of)

    2002-03-01

    To determine the efficacy of an abdominal aortic aneurysm model for stent-graft placement. The model consists of two parts, the heart and the vascular system. A peristaltic pump and a solenoid valve were used to simulate a pulsatile flow from the heart. A ball-shaped piece of clay was placed inside a square box and liquid silicone was poured. After the silicone was formed, the clay was removed and a silicone tube was used to connect the heart model and the aneurysm model. The silicone tube was also used to simulate the iliac arteries and one end of the artery was clampled and the other one was extended to water bath. Water at 37 .deg. C was circulated through the model, and the pressure at the thoracic aorta, aneurysm and iliac artery was measured with the outlet valve opening at 25, 50, and 100% before and after stent-graft placement. The liquid pressure measurements were 253/252, 271/162 and 264/166 mmHg at the thoracic aorta, aneurysm and iliac artery, respectively, when the outlet was 100% open. They were 173/121, 145/99, 145/106 mmHg when the outlet was 50% open, and 35/28, 61/44, 24/22 mmHg when it was 25% open. After placement of the stent-graft, the pressure measurements were 170/128, and 167/128 mmHg, respectively. Since it was easy to produce, the model was useful for in-vitro stent-graft testing, and a wide range of pressure could be applied.

  2. A Novel Attempt to Standardize Results of CFD Simulations Basing on Spatial Configuration of Aortic Stent-Grafts.

    Directory of Open Access Journals (Sweden)

    Andrzej Polanczyk

    Full Text Available Currently, studies connected with Computational Fluid Dynamic (CFD techniques focus on assessing hemodynamic of blood flow in vessels in different conditions e.g. after stent-graft's placement. The paper propose a novel method of standardization of results obtained from calculations of stent-grafts' "pushing forces" (cumulative WSS--Wall Shear Stress, and describes its usefulness in diagnostic process. AngioCT data from 27 patients were used to reconstruct 3D geometries of stent-grafts which next were used to create respective reference cylinders. We made an assumption that both the side surface and the height of a stent-graft and a reference cylinder were equal. The proposed algorithm in conjunction with a stent-graft "pushing forces" on an implant wall, allowed us to determine which spatial configuration of a stent-graft predispose to the higher risk of its migration. For stent-grafts close to cylindrical shape (shape factor φ close to 1 WSS value was about 267 Pa, while for stent-grafts different from cylindrical shape (φ close to 2 WSS value was about 635 Pa. It was also noticed that deformation in the stent-graft's bifurcation part impaired blood flow hemodynamic. Concluding the proposed algorithm of standardization proved its usefulness in estimating the WSS values that may be useful in diagnostic process. Angular bends or tortuosity in bifurcations of an aortic implant should be considered in further studies of estimation of the risk of implantation failure.

  3. Development of tissue-engineered self-expandable aortic stent grafts (Bio stent grafts) using in-body tissue architecture technology in beagles.

    Science.gov (United States)

    Kawajiri, Hidetake; Mizuno, Takeshi; Moriwaki, Takeshi; Ishibashi-Ueda, Hatsue; Yamanami, Masashi; Kanda, Keiichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2015-02-01

    In this study, we aimed to describe the development of tissue-engineered self-expandable aortic stent grafts (Bio stent graft) using in-body tissue architecture technology in beagles and to determine its mechanical and histological properties. The preparation mold was assembled by insertion of an acryl rod (outer diameter, 8.6 mm; length, 40 mm) into a self-expanding nitinol stent (internal diameter, 9.0 mm; length, 35 mm). The molds (n = 6) were embedded into the subcutaneous pouches of three beagles for 4 weeks. After harvesting and removing each rod, the excessive fragile tissue connected around the molds was trimmed, and thus tubular autologous connective tissues with the stent were obtained for use as Bio stent grafts (outer diameter, approximately 9.3 mm in all molds). The stent strut was completely surrounded by the dense collagenous membrane (thickness, ∼150 µm). The Bio stent graft luminal surface was extremely flat and smooth. The graft wall of the Bio stent graft possessed an elastic modulus that was almost two times higher than that of the native beagle abdominal aorta. This Bio stent graft is expected to exhibit excellent biocompatibility after being implanted in the aorta, which may reduce the risk of type 1 endoleaks or migration. © 2014 Wiley Periodicals, Inc.

  4. A Meta-Analysis of Outcomes After In Situ Reconstructions for Aortic Graft Infection.

    Science.gov (United States)

    Batt, Michel; Feugier, Patrick; Camou, Fabrice; Coffy, Amandine; Senneville, Eric; Caillon, Jocelyne; Calvet, Brigitte; Chidiac, Christian; Laurent, Frederic; Revest, Matthieu; Daures, Jean Pierre

    2018-05-01

    To confirm the advantage of in situ reconstruction (ISR) over extra-anatomic reconstruction (EAR) for aortic graft infection and determine the most appropriate conduit including autogenous veins, cryopreserved allografts, and synthetic prosthesis (standard, rifampicin of silver polyesters). A meta-analysis was conducted with rate of mortality, graft occlusion, amputation, and reinfection. A meta-regression was performed with 4 factors: patients' age, presence of prosthetic-duodenal fistula (PDF), virulent organisms, or nonvirulent organisms. In situ reconstruction over EAR seems to favor all events. For the 5 conduits used for ISR, according to operative mortality, age of the patients looks to have a positive correlation only for silver polyester and no conduit present any advantage in the presence of PDF. Reinfection seems to be not significantly different for the 5 conduits, and only autogenous veins appear to have a positive correlation with infecting organisms. In situ reconstruction may be considered as first-line treatment. Our results suggest that silver polyesters appear to be most appropriate for older patients, and in order to limit reinfection, autogenous veins are probably the most suitable conduit.

  5. A composed graft for subclavian artery reconstruction in case of redo surgery for aortic coarctation

    Directory of Open Access Journals (Sweden)

    Fabrizio Sansone

    2013-01-01

    Full Text Available We report the case of a 66-year-old woman admitted to the intensive care unit (ICU for ongoing dyspnea and hemoptoe. She was operated upon in 1979 for aortic coarctation by the interposition of a 14 mm Dacron prosthesis from the left subclavian artery to descending aorta. Clinical evaluation performed over the years was normal with no signs of cardiac failure or prosthesis malfunctioning. The computed tomography scans (CT showed a progressive increase of the descending aorta diameters and the onset of a pseudo-aneurysm of 50 mm in diameter. Patient was re-operated through a median sternotomy enlarged by a left thoracotomy and intra-operative findings revealed the pseudo-aneurysm originating from a dehiscence of the proximal suture. In order to allow a safe reconstruction of the dilated subclavian artery, a T-shaped composed graft was confectioned and then sutured to the descending aorta and the subclavian artery, respectively. Post-operative course was uneventful and three months CT scan showed a normal position of the composed graft.

  6. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

    DEFF Research Database (Denmark)

    Eggebrecht, Holger; Thompson, Matt; Rousseau, Hervé

    2009-01-01

    BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic...

  7. [A re-operative case of bentall operation and aortic arch replacement using a stent graft for a Marfan syndrome, post sternum turnover and post mitral valve replacement].

    Science.gov (United States)

    Sasaki, H; Aomi, S; Noji, S; Uwabe, K; Kihara, S; Kurihara, H; Koyanagi, H

    2001-09-01

    A 36-year-old male with Marfan syndrome succesfully underwent Bentall operation and aortic arch replacement using a stent graft as an elephant trunk. He had received MVR with sternum turn over 14 years previously. Median sternotomy was performed. Under circulatory arrest with rertograde cerebral perfusion we performed Bentall operation and aortic arch replacement using a stent graft. The sternum was cured well. Retractive breathing was not detected. This surgical procedure was effective for cardiovascular disease with Marfan syndrome.

  8. Valve-Sparing Root Replacement Compared With Composite Valve Graft Procedures in Patients With Aortic Root Dilation.

    Science.gov (United States)

    Ouzounian, Maral; Rao, Vivek; Manlhiot, Cedric; Abraham, Nachum; David, Carolyn; Feindel, Christopher M; David, Tirone E

    2016-10-25

    Although aortic valve-sparing (AVS) operations are established alternatives to composite valve graft (CVG) procedures for patients with aortic root aneurysms, comparative long-term outcomes are lacking. This study sought to compare the results of patients undergoing AVS procedures with those undergoing CVG operations. From 1990 to 2010, a total of 616 patients age Marfan syndrome and lower rates of bicuspid aortic valve than those undergoing bio-CVG or m-CVG procedures. In-hospital mortality (0.3%) and stroke rate (1.3%) were similar among groups. After adjusting for clinical covariates, both bio-CVG and m-CVG procedures were associated with increased long-term major adverse valve-related events compared with patients undergoing AVS (hazard ratio [HR]: 3.4, p = 0.005; and HR: 5.2, p valve-related complications when compared with bio-CVG and m-CVG. AVS is the treatment of choice for young patients with aortic root aneurysm and normal or near-normal aortic cusps. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Midterm results of endovascular stent graft treatment for descending aortic aneurysms including high-risk patients

    Directory of Open Access Journals (Sweden)

    Gussmann, Andreas

    2006-04-01

    Full Text Available Methods: 21 patients (17 men, 4 women; mean age 66.1 years, range 29-90 years with 15 true aneurysms, and 6 type B-dissections were treated by implantation of a TalentTM Endoluminal Stentgraft System from February 2000 to July 2003. In 3 cases it was necessary to overstent the left subclavian artery, in 1 case to overstent the left common carotid. Results: 2 patients (9.5% died during the first 30 days (1 myocardial infarction, 1 pneumonia. Two patients (9.5% suffered from cerebral ischemia and needed revascularisation. No paraplegia, no stroke occurred. One endoleak required additional stenting. No patient needed conversion. Follow-up, average 25.4 months (range 0-39, was 100% complete. During this another two patients died of myocardial infarction i.e. 9.5% (the above mentioned endoleak, but no late migration were detected in the remaining patients. In all cases the graft lumen stayed patent. Conclusions: Treatment of descending thoracic aortic aneurysm with an endovascular approach has acceptable mortality and morbidity-rates even in high risk patients. Procedural overstenting of the subclavian artery requires subclavian revascularisation in a minority of cases.

  10. Establishment of a rat and guinea pig aortic interposition graft model reveals model-specific patterns of intimal hyperplasia.

    Science.gov (United States)

    Gregory, Elaine K; Vercammen, Janet M; Flynn, Megan E; Kibbe, Melina R

    2016-12-01

    Although the aortic interposition bypass model has been widely used to evaluate biomaterials for bypass grafting, there is no comprehensive description of the procedure or of the distribution of intimal hyperplasia that results. The objectives of this study were to (1) review and summarize approaches of aortic interposition grafting in animal models, (2) determine the pertinent anatomy for this procedure, (3) validate this model in the rat and guinea pig, and (4) compare the distribution of intimal hyperplasia that develops in each species. A literature search was performed in PubMed from 1980 to the present to analyze the use of anesthesia, anticoagulation, antiplatelet agents, graft material, suture, and anastomotic techniques. Using 10-week-old male Sprague-Dawley rats and Hartley guinea pigs, we established pertinent aortic anatomy, developed comparable models, and assessed complications for each model. At 30 days, the graft and associated aorta were explanted, intimal formation was assessed morphometrically, and cellularity was assessed via nuclear counting. We reviewed 30 articles and summarized the pertinent procedural findings. Upon establishing both animal models, key anatomic differences between the species that affect this model were noted. Guinea pigs have a much larger cecum, increased retroperitoneal fat, and lack the iliolumbar vessels compared with the rat. Surgical outcomes for the rat model included a 53% technical success rate and a 32% technical error rate. Surgical outcomes for the guinea pig model included a 69% technical success rate and a 31% technical error rate. These two species demonstrated unique distribution of intimal hyperplasia at 30 days. Intimal hyperplasia in the rat model was greatest at two areas, the proximal graft (5400 μm 2 ; P guinea pig model developed similar intimal hyperplasia throughout the graft (4500-5100 μm 2 ; P guinea pig, and describe a unique distribution of intimal formation that results in both species

  11. The Bolton Treovance abdominal stent-graft: European clinical trial design.

    Science.gov (United States)

    Chiesa, R; Riambau, V; Coppi, G; Zipfel, B; Llagostera, S; Marone, E M; Kahlberg, A

    2012-10-01

    Endovascular aortic repair (EVAR) has emerged as a promising, less invasive alternative to conventional open surgery for the treatment of infrarenal abdominal aortic aneurysms (AAAs). In the last 20 years, the application rate of EVAR and its clinical results have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary re-interventions. The Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain) is a new-generation endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. In particular, it is provided with some innovative features as a double layer of proximal barbs (suprarenal and infrarenal) for supplemental fixation, dull barbs between modules to avoid potential leg disconnections, detachable outer sheath provided with a new-design hemostatic valve, and a double improved mechanism (slow motion and "pin and pull") for precise stent-graft deployment. A European prospective, non-randomized, multi-institutional, "first-in-human" trial (the ADVANCE trial) was conducted from March to December 2011 to assess the safety and performance of the Treovance stent-graft system before commercialization. Thirty patients with anatomically suitable non-ruptured AAAs were enrolled at five clinical sites in Italy, Spain, and Germany. EVAR was completed successfully in all patients. The stent-graft was delivered and deployed safely even in heavily angulated or calcified anatomies. No 30-day device-related complications nor deaths were observed. Preliminary experience with the Treovance abdominal stent-graft within the ADVANCE trial was satisfactory with regard to technical success and perioperative clinical results. Follow-up data are needed to assess mid- and long-term clinical outcomes, along with durability of this new-generation endovascular device.

  12. Persistent Intraluminal Pressure After Endovascular Stent Grafting for Type B Aortic Dissection.

    Science.gov (United States)

    Qing, K-X; Chan, Y-C; Ting, A C W; Cheng, S W K

    2016-05-01

    Despite technically successful thoracic endovascular stent graft repair (TEVAR) in patients with Stanford Type B aortic dissection (TBAD), long-term follow up studies have shown that the false lumen may continue to dilate. The aim of this study was to analyze the possible mechanisms leading to such changes from a hemodynamic perspective. Twenty-eight ex vivo fresh porcine TBAD models (Mo A: 10; Model B: 12; Model C: 6) were established to simulate three clinical situations: Model A with patent false lumen (pre-TEVAR); Model B with distal re-entry only (post-TEVAR), and Model C with thrombus filling in the false lumen and a distal re-entry (chronic stage of post-TEVAR). Synchronous pressure waveforms were taken from both the true and the false lumen. True lumen and false lumen pressure differences were calculated for each model as four indices: systolic index (SI), diastolic index (DI), mean pressure index (MPI) and area under curve index (AUCI). These indices were compared between the three models. False lumen pressure and corresponding pressure-accumulating effects were significantly higher in Model A than in Model C: SI (99.9% vs. 189.4%; p area under curve (AUC) in Model C was merely lowered by 20% compared with its true lumen (67.5 mmHg vs. 85.2 mmHg). The false lumen pressure remained unchanged in the non-thrombosed segment with patent blood flow after the primary entry tear sealed. Intraluminal pressure reduction in the thrombosed false lumen was significant. However, nearly 80% of the pressure remained in the thrombosed false lumen. If this high intra-thrombus pressure persists, it may contribute to delayed aneurysmal formation after endovascular treatment. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Retrograde type A dissection: a serious complication due to thoracic aortic endovascular stent-graft repair for Stanford type B aortic dissection

    International Nuclear Information System (INIS)

    Wang Guoquan; Zhai Shuiting; Li Tianxiao; Shi Shuaitao; Zhang Kewei; Li Kun

    2011-01-01

    Objective: to discuss the possible causes and prevention of retrograde type A dissection occurred after thoracic aortic endovascular stent-graft repair (TEVAR) for symptomatic type B dissection. Methods: During the period from January 2005 to January 2011, TEVAR was carried out in 189 patients (157 males and 32 females) with symptomatic type B dissection. The average age of the patients was (51.2±13.5) years, ranged from 26 to 78 years. A follow-up lasting for 3-63 months (mean 32 months) was conducted in 135 patients (71.43%). Fifty-four patients lost in touch with the authors (28.57%). The occurrence of retrograde type A dissection after TEVAR was calculated and the possible causes were analyzed. Results: After TEVAR retrograde type A dissection occurred in two patients (1.48%), and both were males. One patient developed retrograde type A dissection in perioperative period, and the patient refused to have surgery. Conservative treatment was employed for over three years and be was still alive so far. The other patient developed retrograde type A dissection one month after TEVAR, and emergency surgery was performed. The patient was followed up for three months and he was still alive. Conclusion: The retrograde type A dissection occurred after TEVAR may be closely related to the stent-graft device, to the interventional manipulations and to the vascular disorders. Close attention should be paid to the direct damage produced by the stent-graft device to the vascular wall. (authors)

  14. Assessment of value of spiral CT in preoperative evaluation of endovascular graft exclusion for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Jing Zaiping; Zhao Jun; Zhu Wenjiang; Xiao Yi

    1998-01-01

    Purpose: The assess the value of spiral CT (SCT) in preoperative evaluation of endovascular graft exclusion (EVGE) for abdominal aortic aneurysm (AAA). Methods: 41 case with AAA received SCT scanning. Two and three dimensional images were reconstructed, utilizing the shaded surface display (SSD), maximum-intensity Projection (MIP) and multiplanar reformation (MPR). Information were obtained regarding the size and features of AAA, length and diameters of aneurysm's neck, status of the branches of aorta, etc. Results: Nine patients had spinal CT study prior EVGE procedure and the grafts selected according to the parameters obtained by SCT matched perfectly to the needs of deployment. Conclusion: CTA provides high quality images. It is a high-speed and non-invasive method which can provide three-dimensional images of AAA and its main branches and all the parameters needed in EVGE

  15. Endovascular stent-graft placement for the treatment of acute onset and chronic aortic dissections of the descending aorta (Short-term follow-up)

    International Nuclear Information System (INIS)

    Petrov, I; Jorgova, J.; Trendafilova, D.

    2004-01-01

    The leading cause of death for patients with surgically untreated thoracic aortic aneurysms is the rupture of the aneurysm. Almost one half of these patients are left to medical treatment assuming the risk of late rupture and aneurysm sac enlargement - the late surgical treatment of these patients is too risky and with poor results. On the other hand the emergent surgical treatment of these cases is related with relatively high mortality rate. Recently, thoracic aortic stent-grafting has emerged as a less traumatic alternative therapeutic modality for patients with thoracic aortic aneurysms and aortic dissections. The first case of stent implantation in a dissected descending aorta was performed in Bulgaria at 09.04.2003. Since then we implanted in 8 patients thoracic stent grafts, The mean age of the patients was 67.5 years. The primary success was 100%. One died on the second postoperative day by abdominal aorta rupture. No other complications were registered. The mean follow-up of 5 months proved to be uneventful and the control CT revealed efficacious sealing of the entry and false lumen thrombosis in all except one cases. We report our initial clinical experience of endovascular stent-graft repair for dissection of the descending aorta that is encouraging. These preliminary data suggest that endovascular stent-grafting is a viable treatment for acute onset and chronic aortic dissection type B

  16. Retrosternal friction-induced late disruption of the anastomotic site between Bentall's valved conduit and an aortic arch graft: report of a case.

    Science.gov (United States)

    Fukada, Johji; Morishita, Kiyofumi; Kawaharada, Nobuyoshi; Kurimoto, Yoshihiko; Muraki, Satoshi; Satsu, Takuma; Abe, Tomio

    2003-01-01

    We report a case of late mediastinal false aneurysm originating from disruption of the suture line between synthetic vascular grafts for aortic root and total aortic arch replacements. This aneurysm developed without any infection in a patient with Marfan's syndrome. To our knowledge, this event has never been reported before. The only possible cause of this disruption was that the monofilament suture was broken by continuous friction between the pointed anastomotic line and the sternum since the operation. The treatment options for this unusual event after extended synthetic graft replacement are discussed.

  17. Use of modified Sandwich-graft technique to preserve hypogastric artery in EVAR treatment of complex aortic aneurysm anatomy.

    Science.gov (United States)

    Mosquera Arochena, N; Rodríguez Feijoo, G; Carballo Fernandez, C; Molina Herrero, F; Fernandez Lebrato, R; Barrios Castro, A; Garcia Fernandez, I

    2011-10-01

    Since the introduction of the first endoprosthetic devices, continuous development in techniques and implants has occurred, such as the introduction of a stent graft with branches designed to preserve antegrade flow in the hypogastric artery, a stent-graft designed to treat extreme neck angulation and iliac tortuosity, as well as "Sandwich" and "Chimney" techniques used to maintain perfusion in branch vessels originating in the region to be treated. This paper describes how the Sandwich-Graft technique was adapted, as described by Lobato et al., employing the Aorfix™ system (Lombard Medical) and the Viabahn™ (W.L.Gore) to preserve hypogastric flow in cases with extreme neck angulation and iliac tortuosity. The study included four patients treated from April 2010 until November 2010 with the modified Sandwich technique. All patients eligible for this approach were considered unfit for open repair and were not suitable for an iliac branch graft (Z-BIS Zenith™ Cook Medical). A bifurcated endograft was implanted with specific, in-situ, branching to the target hypogastric artery and achieved clinical and technical success, in all the patients. After a 11-month follow-up in two cases and a six-month follow-up in the other two, clinical results were successful. All patients were endoleak-free, had patent hypogastric branches and had shrinking or stable aneurysms. The initial experience shows that the Sandwich technique with the Aorfix™ stent-graft demonstrated to be effective in endovascular repair of abdominal aortic aneurysms in patients with aortoiliac anatomy hostile to preserving hypogastric artery patency. This graft allows a broader group of patients to be treated with endovascular repair without potential complications of hypogastric artery occlusion; however, further studies are needed to evaluate long-term results in larger numbers of patients.

  18. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    Energy Technology Data Exchange (ETDEWEB)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua [University Hospital, University of Cologne, Department of Radiology, Cologne (Germany); Pfister, Roman [University Hospital, University of Cologne, Department of Internal Medicine III, Cologne (Germany); Deppe, Antje-Christin [University Hospital, University of Cologne, Department of Cardiothoracic Surgery, Cologne (Germany); Matoussevitch, Vladimir [University Hospital, University of Cologne, Department of Vascular Surgery, Cologne (Germany)

    2014-06-15

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  19. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    International Nuclear Information System (INIS)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua; Pfister, Roman; Deppe, Antje-Christin; Matoussevitch, Vladimir

    2014-01-01

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  20. Thoracic aortic stent-graft placement combined with left subclavian artery 'chimney operation': therapeutic analysis of 15 cases with insufficient proximal anchor area

    International Nuclear Information System (INIS)

    Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi

    2012-01-01

    Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with

  1. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  2. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    International Nuclear Information System (INIS)

    Sun, Zhonghua; Chaichana, Thanapong

    2010-01-01

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair

  3. Anesthesia Approach in Endovascular Aortic Reconstruction

    Directory of Open Access Journals (Sweden)

    Ayşin Alagöl

    2013-03-01

    Full Text Available Introduction: We have analyzed our initial results of our anesthesia techniques in our new-onset endovascular aortic reconstruction cases.Patients and Methods: The perioperative data of 15 elective and emergent endovascular aortic reconstruction cases that were operated in 2010-2011 were collected in a database. The choice of anesthesia was made by the risk factors, surgical team’s preferences, type and location of the aortic pathology and by the predicted operation duration. The data of local and general anesthesia cases were compared.Results: Thirteen (86.7% cases were male and 2 (13.3% female. Eleven patients were in ASA Class III. The demographic parameters, ASA classifications, concurrent diseases were similar in both groups. Thirteen (86.7% cases had infrarenal abdominal aortic aneurysm and 2 (13.3% had Type III aortic dissection. The diastolic arterial pressures were lower in general anesthesia group in 20th and 40th minutes’ measurements just like the mean arterial pressure measurements at the 40th, 100th minutes and during the deployment of the graft. Postoperative mortality occurred in 3 (20.0% patients and they all had general anesthesia and they were operated on emergency basis. Postoperative morbidity occurred in four patients that had general anesthesia (acute renal failure, multi-organ failure and pneumonia. The other patient had atrial fibrillation on the 1st postoperative day and was converted to sinus rhythm with amiodarone infusion.Conclusion: Edovascular aortic reconstruction procedures can safely be performed with both general and local anesthesia less invasively compared to open surgery. General anesthesia may be preferred for the better hemodynamic control.

  4. Laser Fenestration of Aortic Stent-Grafts Followed by Noncompliant vs Cutting Balloon Dilation: A Scanning Electron Microscopy Study.

    Science.gov (United States)

    Lin, Jing; Parikh, Niraj; Udgiri, Naval; Wang, Shaoxia; Miller, Daniel F; Li, Chaojing; Panneton, Jean; Nutley, Mark; Zhang, Ze; Huang, Yunfan; Lu, Jun; Zhang, Jingyi; Wang, Lu; Guidoin, Robert

    2018-06-01

    To examine the effects of in situ laser fenestration and subsequent balloon dilation (noncompliant vs cutting) on the graft fabric of 4 aortic stent-graft models. In an in vitro setup, the Zenith TX2, Talent, Endurant, and Anaconda aortic stent-grafts (all made of polyester graft material) were subjected to laser fenestration with a 2.3-mm-diameter probe at low and high energy in a physiologic saline solution followed by balloon dilation of the hole. For the first series of tests, 6-mm-diameter noncompliant balloons were used and replaced for the second series by 6-mm-diameter cutting balloons. Each procedure was performed 5 times (5 fenestrations per balloon type). The fenestrations were examined visually and with light and scanning electron microscopy. Each fenestration demonstrated various degrees of fraying and/or tearing regardless of the device. The monofilament twill weave of the Talent endograft tore in the warp direction up to 7.09±0.46 mm at high energy compared with 2.41±0.26 mm for the Endurant multifilament device. The fenestrations of the 3 endografts with multifilament weave (Zenith, Anaconda, and Endurant) showed more fraying; fenestration areas in the multifilament Endurant were >10 mm 2 at low and high energy. The fenestrations were free of melted fibers, but minor blackening of the filaments was observed in all devices. Overall, the cutting balloons resulted in worse tearing and damage. Of note, the edges of the dilated laser-formed fenestrations of the Talent and the Endurant grafts demonstrated evidence of additional shredded yarns. In situ fenestration does not cause any melting of the polyester; however, the observed structural damage to the fabric construction must be carefully considered. Cutting balloons caused various levels of tearing compared to the noncompliant balloons and cannot be recommended for use in this application. Rather, noncompliant balloons should be employed, but only with endografts constructed from multifilament yarns

  5. Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outcomes in Patients with Large Iliac Arteries

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; McCollum, Charles N.; Ashleigh, Raymond J.

    2008-01-01

    The purpose of this study is to report outcomes following endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with ectatic common iliac arteries (CIAs). Of 117 AAA patients treated by EVAR between 1998 and 2005, 87 (74%) had CIAs diameters 18 but <25 mm. All patients were treated with Talent stent-grafts, 114 bifurcated and 3 AUI devices. Departmental databases and patient records were reviewed to assess outcomes. Technical success, iliac-related outcome, and iliac-related reintervention (IRSI) were analyzed. Patients with EVAR extending into the external iliac artery were excluded. Median (range) follow-up for the study group was 24 (1-84) months. Initial technical success was 98% for CIAs <18 mm and 100% for CIAs ≥18 mm (p = 0.551). There were three distal type I endoleaks (two in the ectatic group) and six iliac limb occlusions (one in an ectatic patient); there were no statistically significant differences between groups (p = 0.4). There were nine IRSIs (three stent-graft extensions, six femorofemoral crossover grafts); three of these patients had one or both CIAs ≥18 mm (p = 0.232). One-year freedom from IRSI was 92% ± 3% and 84% ± 9% for the <18-mm and ≥18-mm CIA groups, respectively (p = 0.232). We conclude that the treatment of AAA by EVAR in patients with CIAs 18-24 mm appears to be safe and effective, however, it may be associated with more frequent reinterventions.

  6. Surgical treatment of pararenal aortic aneurysms in the elderly.

    Science.gov (United States)

    Illuminati, G; D'Urso, A; Ceccanei, G; Caliò, F; Vietri, F

    2007-12-01

    Until fenestrated endografts will become the standard treatment of pararenal aortic aneurysms, open surgical repair will currently be employed for the repair of this condition. Suprarenal aortic control and larger surgical dissection represent additional technical requirements for the treatment of pararenal aneurysms compared to those of open infrarenal aortic aneurysms, which may be followed by an increased operative mortality and morbidity rate. As this may be especially true when dealing with pararenal aneurysms in an elderly patients' population, we decided to retrospectively review our results of open pararenal aortic aneurysm repair in elderly patients, in order to compare them with those reported in the literature. Twenty-one patients over 75 years of age were operated on for pararenal aortic aneurysms in a ten-year period. Exposure of the aorta was obtained by means of a retroperitoneal access, through a left flank incision on the eleventh rib. When dealing with interrenal aortic aneurysm the left renal artery was revascularized with a retrograde bypass arising from the aortic graft, proximally bevelled on the ostium of the right renal artery. Two patients died of acute intestinal ischemia, yielding a postoperative mortality of 9.5%. Nonfatal complications included 2 pleural effusions, a transitory rise in postoperative serum creatinine levels in 3 cases, and one retroperitoneal hematoma. Mean renal ischemia time was 23 min, whereas mean visceral ischemia time was 19 min. Mean inhospital stay was 11 days. Pararenal aortic aneurysms in the elderly can be surgically repaired with results that are similar to those obtained in younger patients.

  7. The effect of endoleak on intra-aneurysmal pressure after EVE for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Huang Sheng; Jing Zaiping; Mei Zhijun; Lu Qingsheng; Zhao Jun; Zhang Suzhen; Zhao Xin; Cai Lili; Tang Jingdong; Xiong Jiang; Liao Mingfang

    2003-01-01

    Objective: To investigate the intra-aneurysmal pressure curve in the presence of endoleak after endovascular exclusion (EVE) for abdominal aortic aneurysm (AAA). Methods: Infrarenal aortic aneurysms were created with bovine jugular vein segments or patches. Then they were underwent incomplete endovascular exclusion of the aneurysm and formation of endoleaks. The pressures of blood flow outside the graft into the sac were measured. Results: The intrasac pressure was higher than systemic pressure in the presence of endoleak. After sealing the endoleak, pressure decreased significantly, and the pressure cure showed approximately linear. Conclusion: The change of intra-aneurysmal pressure curve reflected the load on aneurysmal wall after EVE, and can also help to determine the endoleak existence

  8. Aortic arch/elephant trunk procedure with Sienna(TM) graft and endovascular stenting of thoraco-abdominal aorta for treatment of complex chronic dissection.

    Science.gov (United States)

    Wong, Randolph H L; Baghai, Max; Yu, Simon C H; Underwood, Malcolm J

    2013-05-01

    Aneurismal dilatation of the remaining thoracic aorta after ascending aortic interposition grafting for type 'A' aortic dissection is not uncommon. For such complex cases, one treatment option is total arch replacement and elephant trunk procedure with the Sienna(TM) collared graft (Vascutek, Inchinnan, UK) technique followed by a staged thoracic endovascular aortic repair (TEVAR). The video illustrates our technique in a 56-year-old man with an extensive aortic arch and descending thoracic aortic dissecting aneurysm. For the 'open' procedure femoral arterial and venous cannulation was used along with systemic cooling and circulatory arrest at 22 °C. Upon circulatory arrest, the aortic arch was incised and antegrade cerebral perfusion achieved via selective cannulation to the right brachiocephalic and left common carotid artery, keeping flow rates at 10-15 mL/kg/min and perfusion pressure at 50-60 mmHg. Arch replacement with an elephant trunk component was then performed and after completion of the distal aortic anastomosis antegrade perfusion via a side-arm in the graft was started and the operation completed using a variation of the 'sequential' clamping technique to maximize cerebral perfusion. The second endovascular stage was performed two weeks after discharge. Two covered stents were landing from the elephant trunk to the distal descending thoracic aorta, to secure the distal landing a bare stent of was placed to cover the aorta just distal to the origin of the celiac axis. The left subclavian artery was embolised with fibre coils. Post TEVAR angiogram showed no endoleak Although re-operative total arch replacement and elephant trunk procedure and subsequent TEVAR remained a challenging procedure, we believe excellent surgical outcome can be achieved with carefully planned operative strategy.

  9. Chimney-Graft as a Bail-Out Procedure for Endovascular Treatment of an Inflammatory Juxtarenal Abdominal Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    Francesca Fratesi

    2015-01-01

    Full Text Available Inflammatory and juxtarenal Abdominal Aortic Aneurysm (j-iAAA represents a technical challenge for open repair (OR due to the peculiar anatomy, extensive perianeurysmal fibrosis, and dense adhesion to the surrounding tissues. A 68-year-old man with an 11 cm asymptomatic j-iAAA was successfully treated with elective EVAR and chimney-graft (ch-EVAR without postprocedural complications. Target vessel patency and normal renal function are present at 24-month follow-up. The treatment of j-iAAA can be technically challenging. ch-EVAR is a feasible and safe bail-out method for elective j-iAAA with challenging anatomy.

  10. Ischaemia of the medullary cone after stent-graft implantation in a patient with abdominal aortic aneurysm - a case study.

    Science.gov (United States)

    Wachowski, Mariusz; Polguj, Michał; Ścibór, Janusz; Majos, Agata

    2018-03-01

    Preoperative visualization of the Adamkiewicz artery - the vessel which is to a great extent responsible for supplying blood to the medullary cone - is an important step which must be taken before initiating restorative procedures in the aorta. We present a case of a 67-year-old patient who underwent an intravascular stent-graft implantation procedure, due to clinical signs of abdominal aortic aneurysm. Routine pre-operative computed tomography examination failed to demonstrate the Adamkiewicz artery. On the second day after the surgery, as a result of unexpected clinical deterioration, an magnetic resonance imaging examination of the lumbar spine was carried out. Based on the magnetic resonance imaging images and clinical manifestations the diagnosis of ischaemia of the medullary cone was made. In our work we also present a deep analysis of the anatomy of small-sized vessels supplying blood to the spinal cord and discuss effective techniques which enable visualization of the Adamkiewicz artery.

  11. Contemporary management of symptomatic primary aortic mural thrombus.

    Science.gov (United States)

    Verma, Himanshu; Meda, Narendranadh; Vora, Simit; George, Robbie K; Tripathi, Ramesh K

    2014-12-01

    Primary aortic mural thrombus (PAMT) is an uncommon condition but an important source of noncardiogenic emboli with a difficult diagnosis and a high rate of complications, including high mortality. We report our experience of thromboembolic disease from PAMT and review its contemporary management. Retrospective analysis of prospectively collected data of all patients who presented with acute occlusion of a limb or visceral vessels between January 2011 and September 2013 was performed. A total of 88 patients presented with acute occlusion of the extremities or visceral arteries. All underwent extensive evaluation for the possible source of the embolism. Of these 88 patients, 19 patients (mean age, 41.2 years; male:female ratio, 1:2.1) were found to have aortic mural thrombus as the source of distal embolism. Thrombus was located in the thoracic aorta in 10 patients, in the perivisceral aorta in three patients, and in the infrarenal aorta in six patients. Thrombus in the thoracic aorta was treated with stent grafts in four patients, bare metal stents in three patients, and anticoagulation alone in two patients. In the suprarenal abdominal aorta, all three patients underwent trapdoor aortic thrombectomy. Infrarenal aortic thrombus was managed by aortobifemoral embolectomy in two patients, aortic stenting in two patients, surgical thrombectomy in one patient, and anticoagulation alone in one patient. Successful treatment, defined as freedom from further embolic events or recurrence of thrombus, was achieved in 14 of 19 patients (76.4%) with a mean follow-up period of 16.2 months (range, 2-28 months). There were four (21%) thrombus-related deaths, all due to primary thromboembolic insults. One patient needed a below-knee amputation because of a recurrent thrombotic episode. Symptomatic PAMT is an uncommon but important source of noncardiogenic embolus. It appears to occur more frequently in young women. Endovascular coverage of the aortic thrombus, when feasible

  12. 3D printed abdominal aortic aneurysm phantom for image guided surgical planning with a patient specific fenestrated endovascular graft system

    Science.gov (United States)

    Meess, Karen M.; Izzo, Richard L.; Dryjski, Maciej L.; Curl, Richard E.; Harris, Linda M.; Springer, Michael; Siddiqui, Adnan H.; Rudin, Stephen; Ionita, Ciprian N.

    2017-03-01

    Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. Results: With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. Conclusions: With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging.

  13. Brucellosis With Multi-Organ Involvement in a Patient With History of Composite Aortic Graft and Hepatitis B.

    Science.gov (United States)

    Dehghan Manshadi, Seyed Ali; Rezahosseini, Omid; Abdi Liaei, Zahra

    2016-11-01

    The brucellosis with multi-organ involvement in a patient with a history of the composite aortic graft (Bentall procedure) and Hepatitis B infection is rare. A 35-year-old man presented to us with fever and loss of consciousness. Four years ago, he was IDU and underwent cardiac surgery because of endocarditis. Recently lumbar spondylodiscitis was diagnosed. The Wright (1/320) and Coombs Wright tests (1/640) were positive. After CNS imaging, lumbar puncture was done. The CSF pleocytosis was lymphocyte dominant. In cardiac echocardiography, large vegetation on prosthetic aortic valve leaflets was seen. The brain MRI was reported abnormal. Treatment of brucellosis started with Ceftriaxone, Doxycycline, Rifampin and Gentamycin. After 4 days, he became oriented, and fever was disappeared then we continued the treatment for 16 days. The patient discharged and followed by daily phone calls. As symptoms of abdominal pain and jaundice were presented on the fifth day, he re-admitted. The patient expired because of hepatorenal and cardiac insufficiency. Drug side effects, activation of Hepatitis B and embolism of cardiac vegetation to other organs were suspected causes of death. We do not suggest medical therapy without cardiac surgery in such cases. When combination therapy is necessary for brucellosis in an HBsAg-positive patient, hepatitis virus activity should be assess by HBV-DNA PCR and the dose of drugs with known hepatotoxic effects such as rifampin and co-trimoxazole should be adjust. Combination therapy with quinolones instead of hepatoxic drugs is one of our suggustions.

  14. Meta-analysis of Renal Function Following Infrarenal EVAR using Suprarenal or Infrarenal Fixation Devices.

    Science.gov (United States)

    Stather, Philip W; Ferguson, James; Awopetu, Ayoola; Boyle, Jonathan R

    2018-03-03

    The effect of suprarenal (SR) as opposed to infrarenal (IR) fixation on renal outcomes post-endovascular aneurysm repair (EVAR) remains controversial. This meta-analysis aims to update current understanding of this issue. A prior meta-analysis was updated through a Preferred Reporting Items for Systematic reviews and Meta-Analyses search for additional studies published in the last 3 years reporting on renal dysfunction or related outcomes post-EVAR. Random effects meta-analysis was undertaken using SPSS. A total of 25 non-randomised studies comparing SR with IR fixation were included, totalling 54,832 patients. In total, 16,634 underwent SR and 38,198 IR. Baseline characteristics, including age, baseline estimated glomerular filtration rate, diabetes, cardiac disease, and smoking, were similar between the groups. There was a small but significant difference in outcomes for renal dysfunction at the study end point (SR 5.98% vs. IR 4.83%; odds ratio [OR] 1.29, 95% confidence interval [CI] 1.18-1.40 [p analysis. Incidence of renal infarcts (SR 6.6% vs. IR 2.3%; OR 2.78, 95% CI 1.46-5.29 [p = .002]), renal stenosis (SR 2.4% vs. IR 0.8%; OR 2.89, 95% CI 1.00-8.38 [p = .05]), and renal artery occlusion (SR 2.4% vs. IR 1.2%; OR 2.21, 95% CI 1.15-4.25 [p = 0.02]) favoured IR fixation; however, there was no difference in haemodialysis rates. This meta-analysis has identified small but significantly worse renal outcomes in patients having SR fixation devices compared with IR; however, there was no difference in dialysis rates and a small effect on renal dysfunction, which did not stand up to rigorous sensitivity analysis. This should be taken into consideration during graft selection, and further studies must assess renal outcomes in the longer term, and in those with pre-existing renal dysfunction. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  15. Influence of surgical implantation angle of left ventricular assist device outflow graft and management of aortic valve opening on the risk of stroke in heart failure patients

    Science.gov (United States)

    Chivukula, V. Keshav; McGah, Patrick; Prisco, Anthony; Beckman, Jennifer; Mokadam, Nanush; Mahr, Claudius; Aliseda, Alberto

    2016-11-01

    Flow in the aortic vasculature may impact stroke risk in patients with left ventricular assist devices (LVAD) due to severely altered hemodynamics. Patient-specific 3D models of the aortic arch and great vessels were created with an LVAD outflow graft at 45, 60 and 90° from centerline of the ascending aorta, in order to understand the effect of surgical placement on hemodynamics and thrombotic risk. Intermittent aortic valve opening (once every five cardiac cycles) was simulated and the impact of this residual native output investigated for the potential to wash out stagnant flow in the aortic root region. Unsteady CFD simulations with patient-specific boundary conditions were performed. Particle tracking for 10 cardiac cycles was used to determine platelet residence times and shear stress histories. Thrombosis risk was assessed by a combination of Eulerian and Lagrangian metrics and a newly developed thrombogenic potential metric. Results show a strong influence of LVAD outflow graft angle on hemodynamics in the ascending aorta and consequently on stroke risk, with a highly positive impact of aortic valve opening, even at low frequencies. Optimization of LVAD implantation and management strategies based on patient-specific simulations to minimize stroke risk will be presented

  16. Management of Endovascular Aortic Aneurysm Complications via Retrograde Catheterization Through the Distal Stent-Graft Landing Zone.

    Science.gov (United States)

    Zhang, Xicheng; Sun, Yuan; Chen, Zhaolei; Jing, Yuanhu; Xu, Miao

    2017-08-01

    A retrograde technique through the gap between the distal stent landing zone and the iliac artery wall has been applied to treat type II endoleak after endovascular aortic aneurysm repair (EVAR). In this study, we tried to investigate its efficacy in the management of type III endoleak and intraoperative accidental events. We reported 2 complications of EVAR that were difficult to treat with conventional methods. One patient had a sustained type III endoleak after EVAR, and the right renal artery was accidentally sealed by a graft stent in the other patient during the operation. Both complications were managed by the retrograde technique from the distal stent landing zone. In the first case, the endoleak was easily embolized by the retrograde catheterization technique, and in the second case, a stent was implanted in the right renal artery using the retrograde technique to restore blood flow. In some EVAR cases, the technique of retrograde catheterization through the distal stent-graft landing zone is feasible, safe, and easy to perform.

  17. Endovascular repair of abdominal aortic aneurysms: vascular anatomy, device selection, procedure, and procedure-specific complications.

    Science.gov (United States)

    Bryce, Yolanda; Rogoff, Philip; Romanelli, Donald; Reichle, Ralph

    2015-01-01

    Abdominal aortic aneurysm (AAA) is abnormal dilatation of the aorta, carrying a substantial risk of rupture and thereby marked risk of death. Open repair of AAA involves lengthy surgery time, anesthesia, and substantial recovery time. Endovascular aneurysm repair (EVAR) provides a safer option for patients with advanced age and pulmonary, cardiac, and renal dysfunction. Successful endovascular repair of AAA depends on correct selection of patients (on the basis of their vascular anatomy), choice of the correct endoprosthesis, and familiarity with the technique and procedure-specific complications. The type of aneurysm is defined by its location with respect to the renal arteries, whether it is a true or false aneurysm, and whether the common iliac arteries are involved. Vascular anatomy can be divided more technically into aortic neck, aortic aneurysm, pelvic perfusion, and iliac morphology, with grades of difficulty with respect to EVAR, aortic neck morphology being the most common factor to affect EVAR appropriateness. When choosing among the devices available on the market, one must consider the patient's vascular anatomy and choose between devices that provide suprarenal fixation versus those that provide infrarenal fixation. A successful technique can be divided into preprocedural imaging, ancillary procedures before AAA stent-graft placement, the procedure itself, postprocedural medical therapy, and postprocedural imaging surveillance. Imaging surveillance is important in assessing complications such as limb thrombosis, endoleaks, graft migration, enlargement of the aneurysm sac, and rupture. Last, one must consider the issue of radiation safety with regard to EVAR. (©)RSNA, 2015.

  18. AP-1 Oligodeoxynucleotides Reduce Aortic Elastolysis in a Murine Model of Marfan Syndrome.

    Science.gov (United States)

    Arif, Rawa; Zaradzki, Marcin; Remes, Anca; Seppelt, Philipp; Kunze, Reiner; Schröder, Hannes; Schwill, Simon; Ensminger, Stephan M; Robinson, Peter N; Karck, Matthias; Müller, Oliver J; Hecker, Markus; Wagner, Andreas H; Kallenbach, Klaus

    2017-12-15

    Marfan syndrome is characterized by high expression of matrix metalloproteinases (MMPs) in aortic smooth muscle cells (AoSMCs) associated with medial elastolysis and aortic root aneurysm. We aimed to reduce aortic elastolysis through decrease of MMP expression with decoy oligodeoxynucleotides (dODNs) neutralizing the transcription factor activating factor-1 (AP-1). AP-1 abundance in nuclear extracts as well as MMP-2 and MMP-9 expression were significantly increased in isolated mAoSMC of mgR/mgR Marfan mice compared to wild-type cells. Exposure to AP-1 neutralizing dODNs resulted in a significant reduction of basal and interleukin-1β-stimulated MMP expression and activity in mAoSMCs. Moreover, increased migration and formation of superoxide radical anions was substantially decreased in mAoSMCs by AP-1 dODN treatment. Aortic grafts from donor Marfan mice were treated with AP-1- dODN ex vivo and implanted as infrarenal aortic interposition grafts in mgR/mgR mice. Pretreatment of aortic grafts with AP-1 dODN led to reduced elastolysis, macrophage infiltration, and MMP activity. Permeability of the endothelial monolayer was increased for dODN in mgR/mgR aortae with observed loss of tight junction proteins ZO-1 and occludin, enabling dODN to reach the tunica media. Targeting AP-1 activity offers a new potential strategy to treat the vascular phenotype associated with Marfan syndrome. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  19. Single-center mid-term experience with chimney-graft technique for the preservation of flow to the supra-aortic branches.

    Science.gov (United States)

    Shahverdyan, Robert; Mylonas, Spyridon; Gawenda, Michael; Brunkwall, Jan

    2018-04-01

    Objectives To investigate the feasibility and the mid-term outcomes of the chimney-graft technique for the revascularization of supra-aortic branches in patients with thoracic aortic pathologies involving the aortic arch. Methods A retrospective analysis of a prospectively maintained database between January 2010 and July 2016 was performed. Primary endpoints were 30-day and overall mortality. Secondary endpoints were technical success, target vessel patency, stroke/transitory ischemic attack and type I/III endoleak rate. Results A total of 30 patients (80% male, median age 70.0 years) were treated using the chimney-graft technique for the supra-aortic branches. The indication was a degenerative aneurysm in nine patients (32%) and a type B Stanford aortic dissection and a penetrating aortic ulcer in the descending aorta in seven patients (23%), respectively. In six patients (20.0%), the indication was an type Ia endoleak after previous endovascular thoracic repair, whereas a pseudoaneurysm after previous open repair of the descending aorta was the indication in one patient (3%). Twenty-three patients (77%) were treated electively, five (17%) emergently and two (7%) urgently because of free rupture. Technical success was achieved in 90% of patients. The 30-day/in-hospital mortality was 17% (5/30). A retrograde dissection was presented in five patients. Four patients experienced a cerebrovascular event. Eight patients had type Ia endoleak and 10 had type II. During the median follow-up of 16 months (range: 0-56), four further patients died: one in respiratory insufficiency, one due to a ruptured abdominal aortic aneurysm, one in meningitis and the last one for unknown reason. The chimney-graft patency was 100%. According to the Kaplan-Meier curve, the estimated survival at one year was 66 ± 9%. Conclusions The chimney-graft technique, despite a technically demanding strategy, is a useful tool as bailout procedure in our armamentarium for high-risk patients

  20. Surgery of the aortic root: should we go for the valve-sparing root reconstruction or the composite graft-valve replacement is still the first choice of treatment for these patients?

    Science.gov (United States)

    Lamana, Fernando de Azevedo; Dias, Ricardo Ribeiro; Duncan, Jose Augusto; Faria, Leandro Batisti de; Malbouisson, Luiz Marcelo Sa; Borges, Luciano de Figueiredo; Mady, Charles; Jatene, Fábio Biscegli

    2015-01-01

    To compare the results of the root reconstruction with the aortic valve-sparing operation versus composite graft-valve replacement. From January 2002 to October 2013, 324 patients underwent aortic root reconstruction. They were 263 composite graft-valve replacement and 61 aortic valve-sparing operation (43 reimplantation and 18 remodeling). Twenty-six percent of the patients were NYHA functional class III and IV; 9.6% had Marfan syndrome, and 12% had bicuspid aortic valve. There was a predominance of aneurysms over dissections (81% vs. 19%), with 7% being acute dissections. The complete follow-up of 100% of the patients was performed with median follow-up time of 902 days for patients undergoing composite graft-valve replacement and 1492 for those undergoing aortic valve-sparing operation. In-hospital mortality was 6.7% and 4.9%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns). During the late follow-up period, there was 0% moderate and 15.4% severe aortic regurgitation, and NYHA functional class I and II were 89.4% and 94%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns). Root reconstruction with aortic valve-sparing operation showed lower late mortality (P=0.001) and lower bleeding complications (P=0.006). There was no difference for thromboembolism, endocarditis, and need of reoperation. The aortic root reconstruction with preservation of the valve should be the operation being performed for presenting lower late mortality and survival free of bleeding events.

  1. Elective reconstruction of thoracoabdominal aortic aneurysm type IV by transabdominal approach

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2012-01-01

    Full Text Available Introduction. Thoracoabdominal aortic aneurysm (TAAA type IV represents an aortic dilatation from the level of the diaphragmatic hiatus to the iliac arteries branches, including visceral branches of the aorta. In the traditional procedure of TAAA type IV repair, the body is opened using thoractomy and laparotomy in order to provide adequate exposure of the descending thoracic and abdominal aorta for safe aortic reconstruction. Case report. We reported a 71-yearold man with elective reconstruction of the TAAA type IV performed by transabdominal approach. Computed tomography scans angiography revealed a TAAA type IV with diameter of 62 mm in the region of celiac trunk and superior mesenteric artery branching, and the largest diameter of 75 mm in the infrarenal aortic level. The patient comorbidity included a chronic obstructive pulmonary disease and hypertension, therefore he was treated for a prolonged period. In preparation for the planned aortic reconstruction asymptomatic carotid disease (occlusion of the left internal carotid artery and subtotal stenosis of the right internal carotid artery was diagnosed. Within the same intervention percutaneous transluminal angioplasty with stent placement in right internal carotid artery was made. In general, under endotracheal anesthesia and epidural analgesia, with transabdominal approach performed aortic reconstruction with tubular dakron graft 24 mm were, and reimplantation of visceral aortic branches into the graft performed. Postoperative course was uneventful, and the patient was discharged on the postoperative day 17. Control computed tomography scan angiography performed three months after the operation showed vascular state of the patient to be in order. Conclusion. Complete transabdominal approach to TAAA type IV represents an appropriate substitute for thoracoabdominal approach, without compromising safety of the patient. This approach is less traumatic, especially in patients with impaired

  2. Grafting

    Energy Technology Data Exchange (ETDEWEB)

    Garnett, J L [New South Wales Univ., Kensington (Australia). School of Chemistry

    1979-01-01

    The unique value of ionizing radiation for the initiation of grafting to backbone polymers is discussed. The principles of the technique are briefly reviewed. The conditions under which free radicals and ions participate in these reactions are examined. Examples of representative grafting processes are considered to illustrate where the technique can be of potential commercial value to a wide range of industries. The general principles of these grafting reactions are shown to be applicable to radiation induced rapid cure technology such as is provided by electron beam processing facilities. Grafting reactions initiated by UV are also treated and shown to be of importance because of the many similarities in properties of the ionizing radiation and UV systems, also the rapid industrial exploitation of EB and sensitized UV processing technology. Possible future trends in radiation grafting are outlined.

  3. Comparison of midterm results for the Talent and Endurant stent graft.

    Science.gov (United States)

    't Mannetje, Yannick W; Cuypers, Philippe W M; Saleem, Ben R; Bode, Aron S; Teijink, Joep A W; van Sambeek, Marc R H M

    2017-09-01

    Stent graft evolution is often addressed as a cause for improved outcomes of endovascular aneurysm repair for patients with an abdominal aortic aneurysm. In this study, we directly compared the midterm result of Endurant stent graft with its predecessor, the Talent stent graft (both Medtronic, Santa Rosa, Calif). Patient treated from January 2005 to December 2010 in a single tertiary center in The Netherlands with a Talent or Endurant stent graft were eligible for inclusion. Ruptured abdominal aortic aneurysms or patients with previous aortic surgery were excluded. The primary end point was the Kaplan-Meier estimated freedom from secondary interventions. Secondary end points were perioperative outcomes and indications for secondary interventions. In total, 221 patients were included (131 Endurant and 90 Talent). At baseline, the median aortic bifurcation was narrower for the Endurant (30 mm vs 39 mm; P Talent and Endurant, respectively. The estimated freedom from secondary interventions at 30 days, 1 year, 5 years, and 7 years was 94.3%, 89.4%, 72.2%, and 64.1% for Talent and 96.8%, 89.3%, 75.2%, and 69.2% for Endurant (P = .528). The indication for secondary interventions does differ; more patients required an intervention for a proximal neck-related complication (type Ia endoleak or migration) in the Talent group (18.2% vs 4.8%; P = .001), whereas more interventions for iliac limb stenosis were seen in the Endurant group (0.0% vs 4.8%; P = .044). In a binomial regression analysis, suprarenal angulation, infrarenal neck length, and type of stent graft were independent predictors of neck-related complications. Evolution from the Talent stent graft into the Endurant has resulted in significant reduction of infrarenal neck-related complications; on the other hand, iliac interventions increased. The overall midterm secondary intervention rate was comparable. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  4. Arch translocation and the intra-arch elephant-trunk technique with collared graft for extended chronic dissecting aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ikenaga Shigeru

    2013-01-01

    Full Text Available Abstract Management of extensive, chronic, dissecting aortic aneurysms after prior repair of the ascending aorta presents a technical challenge for surgeons. A symptomatic 64-year-old patient was admitted for elective surgical repair of an aortic annular dilatation, causing severe aortic regurgitation, and a Crawford type II extended thoracoabdominal aneurysm, 4 years after he underwent primary repair of an acute aortic dissection. The aorta was diffusely dilated, and there were no sites beyond the distal aortic arch where anastomosis could be performed. We successfully performed total aortic replacement with a 2-stage strategy, using an arch translocation technique and an intra-arch elephant-trunk technique.

  5. Effect of acetyl salicylic acid on increased production of thromboxane after aortic graft surgery.

    Science.gov (United States)

    Lewin, J; Swedenborg, J; Egberg, N; Vesterqvist, O; Green, K

    1989-06-01

    Contact between blood and foreign surfaces, e.g. vascular grafts, causes activation and release of platelets. One consequence of platelet activation is production of thromboxane A2 (TxA2). The physiological effects of TxA2, i.e. platelet aggregation and vaso-constriction are counteracted by another prostanoid, prostacyclin (PGI2). Acetylsalicylic acid (ASA) causes a longlasting inhibition of platelet TxA2 production and a more shortlasting inhibition of PGI2 production. The present study examines TxA2 and PGI2 synthesis in patients receiving synthetic arterial grafts, some of which were treated with ASA. The prostanoid synthesis was evaluated by measurement of their main urinary metabolites with gas chromatography-mass spectrometry. Platelet release was evaluated by measurements of beta-thromboglobulin (beta-TG) and the plasma coagulation by measurements of fibrinopeptide A (FPA). These compounds were also measured in urine in order to avoid artifacts caused by activation of platelets and plasma coagulation during blood sampling. Following replacement of the abdominal aorta with a synthetic vascular graft there was a marked increase in the synthesis of TxA2 and PGI2. Increased levels of beta-TG and FPA were also demonstrated. Administration of ASA on the first and second postoperative days significantly reduced the synthesis of TxA2 but caused no significant effects on the other parameters measured. It is concluded that ASA may be beneficial in the postoperative period since it counteracts TxA2 with vasoconstricting and platelet aggregating properties but leaves PGI2 with vasodilating and antiaggregating properties relatively uneffected.

  6. Surgery of the aortic root: should we go for the valve-sparing root reconstruction or the composite graft-valve replacement is still the first choice of treatment for these patients?

    Directory of Open Access Journals (Sweden)

    Fernando de Azevedo Lamana

    2015-09-01

    Full Text Available AbstractObjective:To compare the results of the root reconstruction with the aortic valve-sparing operation versus composite graftvalve replacement.Methods:From January 2002 to October 2013, 324 patients underwent aortic root reconstruction. They were 263 composite graft-valve replacement and 61 aortic valve-sparing operation (43 reimplantation and 18 remodeling. Twenty-six percent of the patients were NYHA functional class III and IV; 9.6% had Marfan syndrome, and 12% had bicuspid aortic valve. There was a predominance of aneurysms over dissections (81% vs. 19%, with 7% being acute dissections. The complete follow-up of 100% of the patients was performed with median follow-up time of 902 days for patients undergoing composite graft-valve replacement and 1492 for those undergoing aortic valve-sparing operation.Results:In-hospital mortality was 6.7% and 4.9%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns. During the late follow-up period, there was 0% moderate and 15.4% severe aortic regurgitation, and NYHA functional class I and II were 89.4% and 94%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns. Root reconstruction with aortic valve-sparing operation showed lower late mortality (P=0.001 and lower bleeding complications (P=0.006. There was no difference for thromboembolism, endocarditis, and need of reoperation.Conclusion:The aortic root reconstruction with preservation of the valve should be the operation being performed for presenting lower late mortality and survival free of bleeding events.

  7. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology (Korea, Republic of); Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C. [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States); Kern, John A.; Cherry, Kenneth J. [University of Virginia Health System, Department of Surgery (United States); Matsumoto, Alan H., E-mail: ahm4d@virginia.edu [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States)

    2012-12-15

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  8. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C.; Kern, John A.; Cherry, Kenneth J.; Matsumoto, Alan H.

    2012-01-01

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 ± 5.6 mm; range 1.5–25.0 mm) and diameter (mean, 13.5 ± 9.7 mm; range 2.2–41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  9. Fenestrated endovascular aortic aneurysm repair using physician-modified endovascular grafts versus company-manufactured devices.

    Science.gov (United States)

    Dossabhoy, Shernaz S; Simons, Jessica P; Flahive, Julie M; Aiello, Francesco A; Sheth, Parth; Arous, Edward J; Messina, Louis M; Schanzer, Andres

    2017-12-07

    Fenestrated endografts are customized, patient-specific endovascular devices with potential to reduce morbidity and mortality of complex aortic aneurysm repair. With approval from the U.S. Food and Drug Administration, our center began performing fenestrated endovascular aneurysm repair through a physician-sponsored investigational device exemption (IDE #G130210), using both physician-modified endografts (PMEGs) and company-manufactured devices (CMDs). Because these techniques are associated with specific advantages and disadvantages, we sought to investigate differences in outcomes between PMEG and CMD cases. A single-institution retrospective review of all fenestrated endovascular aneurysm repairs was performed. The cohort was analyzed by device type (PMEG or CMD) after matching of cases on the basis of (1) number of target vessels intended for treatment, (2) extent of aneurysm, (3) aneurysm diameter, (4) device configuration, and (5) date of operation. Outcomes of ruptures, common iliac artery aneurysms, and aortic arch aneurysms were excluded. Demographics, operative details, perioperative complications, length of stay, and reinterventions were compared. For patients with >1 year of follow-up time, survival, type I or type III endoleak rate, target artery patency, and reintervention rate were estimated using the Kaplan-Meier method. Between November 30, 2010, and July 30, 2016, 82 patients were identified and matched. The cohort included 41 PMEG and 41 CMD patients who underwent repair of 38 juxtarenal (PMEG, 17; CMD, 21; P = .38), 14 pararenal (PMEG, 6; CMD, 8; P = .56), and 30 thoracoabdominal type I to type IV (PMEG, 18; CMD, 12; P = .17) aneurysms. There were significant differences in presentation requiring urgent aneurysm repair (PMEG, 9; CMD, 0; P = .002), total fluoroscopy time (PMEG, 76 minutes; CMD, 61 minutes; P = .02), volume of contrast material used (PMEG, 88 mL; CMD, 70 mL; P = .02), in-operating room to out-of-operating room time

  10. Comparison of neurocognitive results after coronary artery bypass grafting and thoracic aortic surgery using retrograde cerebral perfusion.

    Science.gov (United States)

    Miyairi, Takeshi; Takamoto, Shinichi; Kotsuka, Yutaka; Takeuchi, Atsuko; Yamanaka, Katsuo; Sato, Hajime

    2005-07-01

    Retrograde cerebral perfusion (RCP) is used as an adjunctive method to hypothermic circulatory arrest to enhance cerebral protection in patients undergoing thoracic aortic surgery. It remains unclear whether RCP provides improved neurological and neuropsychological outcome. Forty-six patients undergoing thoracic aortic surgery using RCP, and 28 undergoing coronary artery bypass grafting (CABG; n = 28) with CPB, were enrolled in the study. Patients receiving RCP were subdivided into two groups, those with less than 60 min of RCP (S-RCP; n = 27) and with 60 min or more (L-RCP; n = 19). The patients' neurocognitive state was assessed by the revised Wechsler Adult Intelligence Scale a few days before operation, at 2-3 weeks and 4-6 months after operation. There were no stroke, seizure, and hospital mortality in either group. Significant decline between baseline and early scores were seen in three subtests (digit span, arithmetic, and picture completion) for S-RCP and four (digit span, arithmetic, picture completion, and picture arrangement) for L-RCP. Significant decline between baseline and late scores were seen in one subtest (arithmetic) for S-RCP, four (digit span, arithmetic, picture completion, and picture arrangement) for L-RCP, and one (object assembly) for CABG. The mean change of scores for one late test (digit symbol) was significantly lower in S-RCP than in CABG. The mean change of scores for three early tests (digit span, vocabulary, and picture arrangement) and four late tests (information, digit span, picture completion, and picture arrangement) were significantly lower in L-RCP than in CABG. Stepwise logistic regression analysis disclosed that, after considering the other variables, significant difference in test score changes were observed between CABG and L-RCP for two early tests (picture completion and digit symbol) as well as for three late tests (digit span, similarities, and picture completion). None of test score changes showed significant

  11. Impact of contrast injection and stent-graft implantation on reproducibility of volume measurements in semiautomated segmentation of abdominal aortic aneurysm on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Morin-Roy, Florence; Hadjadj, Sofiane; Thomas, Olivier; Yang, Dan Yang [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada); Kauffmann, Claude [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Tang, An [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Saint-Luc, Department of Radiology, Montreal, Quebec (Canada); Piche, Nicolas [Object Research System, Montreal, Quebec (Canada); Elkouri, Stephane [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Hotel-Dieu, Department of Vascular surgery, Montreal, Quebec (Canada); Therasse, Eric [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Hotel-Dieu, Department of Radiology, Montreal, Quebec (Canada); Soulez, Gilles [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada); University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada)

    2014-07-15

    To assess the impact of contrast injection and stent-graft implantation on feasibility, accuracy, and reproducibility of abdominal aortic aneurysm (AAA) volume and maximal diameter (D-max) measurements using segmentation software. CT images of 80 subjects presenting AAA were divided into four equal groups: with or without contrast enhancement, and with or without stent-graft implantation. Semiautomated software was used to segment the aortic wall, once by an expert and twice by three readers. Volume and D-max reproducibility was estimated by intraclass correlation coefficients (ICC), and accuracy was estimated between the expert and the readers by mean relative errors. All segmentations were technically successful. The mean AAA volume was 167.0 ± 82.8 mL and the mean D-max 55.0 ± 10.6 mm. Inter- and intraobserver ICCs for volume and D-max measurements were greater than 0.99. Mean relative errors between readers varied between -1.8 ± 4.6 and 0.0 ± 3.6 mL. Mean relative errors in volume and D-max measurements between readers showed no significant difference between the four groups (P ≥ 0.2). The feasibility, accuracy, and reproducibility of AAA volume and D-max measurements using segmentation software were not affected by the absence of contrast injection or the presence of stent-graft. (orig.)

  12. Textural features of {sup 18}F-fluorodeoxyglucose positron emission tomography scanning in diagnosing aortic prosthetic graft infection

    Energy Technology Data Exchange (ETDEWEB)

    Saleem, Ben R.; Zeebregts, Clark J. [University of Groningen, University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, P.O. Box 30 001, Groningen (Netherlands); Beukinga, Roelof J.; Slart, Riemer H.J.A. [University of Groningen, University Medical Center Groningen, Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University of Twente, Department of Biomedical Photonic Imaging (BMPI), Enschede (Netherlands); Boellaard, Ronald; Glaudemans, Andor W.J.M. [University of Groningen, University Medical Center Groningen, Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Reijnen, Michel M.P.J. [Rijnstate Hospital, Department of Surgery, Arnhem (Netherlands)

    2017-05-15

    The clinical problem in suspected aortoiliac graft infection (AGI) is to obtain proof of infection. Although {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography scanning (PET) has been suggested to play a pivotal role, an evidence-based interpretation is lacking. The objective of this retrospective study was to examine the feasibility and utility of {sup 18}F-FDG uptake heterogeneity characterized by textural features to diagnose AGI. Thirty patients with a history of aortic graft reconstruction who underwent {sup 18}F-FDG PET/CT scanning were included. Sixteen patients were suspected to have an AGI (group I). AGI was considered proven only in the case of a positive bacterial culture. Positive cultures were found in 10 of the 16 patients (group Ia), and in the other six patients, cultures remained negative (group Ib). A control group was formed of 14 patients undergoing {sup 18}F-FDG PET for other reasons (group II). PET images were assessed using conventional maximal standardized uptake value (SUVmax), tissue-to-background ratio (TBR), and visual grading scale (VGS). Additionally, 64 different {sup 18}F-FDG PET based textural features were applied to characterize {sup 18}F-FDG uptake heterogeneity. To select candidate predictors, univariable logistic regression analysis was performed (α = 0.16). The accuracy was satisfactory in case of an AUC > 0.8. The feature selection process yielded the textural features named variance (AUC = 0.88), high grey level zone emphasis (AUC = 0.87), small zone low grey level emphasis (AUC = 0.80), and small zone high grey level emphasis (AUC = 0.81) most optimal for distinguishing between groups I and II. SUVmax, TBR, and VGS were also able to distinguish between these groups with AUCs of 0.87, 0.78, and 0.90, respectively. The textural feature named short run high grey level emphasis was able to distinguish group Ia from Ib (AUC = 0.83), while for the same task the TBR and VGS were not found to be predictive

  13. Textural features of 18F-fluorodeoxyglucose positron emission tomography scanning in diagnosing aortic prosthetic graft infection.

    Science.gov (United States)

    Saleem, Ben R; Beukinga, Roelof J; Boellaard, Ronald; Glaudemans, Andor W J M; Reijnen, Michel M P J; Zeebregts, Clark J; Slart, Riemer H J A

    2017-05-01

    The clinical problem in suspected aortoiliac graft infection (AGI) is to obtain proof of infection. Although 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography scanning (PET) has been suggested to play a pivotal role, an evidence-based interpretation is lacking. The objective of this retrospective study was to examine the feasibility and utility of 18 F-FDG uptake heterogeneity characterized by textural features to diagnose AGI. Thirty patients with a history of aortic graft reconstruction who underwent 18 F-FDG PET/CT scanning were included. Sixteen patients were suspected to have an AGI (group I). AGI was considered proven only in the case of a positive bacterial culture. Positive cultures were found in 10 of the 16 patients (group Ia), and in the other six patients, cultures remained negative (group Ib). A control group was formed of 14 patients undergoing 18 F-FDG PET for other reasons (group II). PET images were assessed using conventional maximal standardized uptake value (SUVmax), tissue-to-background ratio (TBR), and visual grading scale (VGS). Additionally, 64 different 18 F-FDG PET based textural features were applied to characterize 18 F-FDG uptake heterogeneity. To select candidate predictors, univariable logistic regression analysis was performed (α = 0.16). The accuracy was satisfactory in case of an AUC > 0.8. The feature selection process yielded the textural features named variance (AUC = 0.88), high grey level zone emphasis (AUC = 0.87), small zone low grey level emphasis (AUC = 0.80), and small zone high grey level emphasis (AUC = 0.81) most optimal for distinguishing between groups I and II. SUVmax, TBR, and VGS were also able to distinguish between these groups with AUCs of 0.87, 0.78, and 0.90, respectively. The textural feature named short run high grey level emphasis was able to distinguish group Ia from Ib (AUC = 0.83), while for the same task the TBR and VGS were not found to be predictive. SUVmax

  14. Textural features of "1"8F-fluorodeoxyglucose positron emission tomography scanning in diagnosing aortic prosthetic graft infection

    International Nuclear Information System (INIS)

    Saleem, Ben R.; Zeebregts, Clark J.; Beukinga, Roelof J.; Slart, Riemer H.J.A.; Boellaard, Ronald; Glaudemans, Andor W.J.M.; Reijnen, Michel M.P.J.

    2017-01-01

    The clinical problem in suspected aortoiliac graft infection (AGI) is to obtain proof of infection. Although "1"8F-fluorodeoxyglucose ("1"8F-FDG) positron emission tomography scanning (PET) has been suggested to play a pivotal role, an evidence-based interpretation is lacking. The objective of this retrospective study was to examine the feasibility and utility of "1"8F-FDG uptake heterogeneity characterized by textural features to diagnose AGI. Thirty patients with a history of aortic graft reconstruction who underwent "1"8F-FDG PET/CT scanning were included. Sixteen patients were suspected to have an AGI (group I). AGI was considered proven only in the case of a positive bacterial culture. Positive cultures were found in 10 of the 16 patients (group Ia), and in the other six patients, cultures remained negative (group Ib). A control group was formed of 14 patients undergoing "1"8F-FDG PET for other reasons (group II). PET images were assessed using conventional maximal standardized uptake value (SUVmax), tissue-to-background ratio (TBR), and visual grading scale (VGS). Additionally, 64 different "1"8F-FDG PET based textural features were applied to characterize "1"8F-FDG uptake heterogeneity. To select candidate predictors, univariable logistic regression analysis was performed (α = 0.16). The accuracy was satisfactory in case of an AUC > 0.8. The feature selection process yielded the textural features named variance (AUC = 0.88), high grey level zone emphasis (AUC = 0.87), small zone low grey level emphasis (AUC = 0.80), and small zone high grey level emphasis (AUC = 0.81) most optimal for distinguishing between groups I and II. SUVmax, TBR, and VGS were also able to distinguish between these groups with AUCs of 0.87, 0.78, and 0.90, respectively. The textural feature named short run high grey level emphasis was able to distinguish group Ia from Ib (AUC = 0.83), while for the same task the TBR and VGS were not found to be predictive. SUVmax was found predictive

  15. Healthcare-associated prosthetic heart valve, aortic vascular graft, and disseminated Mycobacterium chimaera infections subsequent to open heart surgery.

    Science.gov (United States)

    Kohler, Philipp; Kuster, Stefan P; Bloemberg, Guido; Schulthess, Bettina; Frank, Michelle; Tanner, Felix C; Rössle, Matthias; Böni, Christian; Falk, Volkmar; Wilhelm, Markus J; Sommerstein, Rami; Achermann, Yvonne; Ten Oever, Jaap; Debast, Sylvia B; Wolfhagen, Maurice J H M; Brandon Bravo Bruinsma, George J; Vos, Margreet C; Bogers, Ad; Serr, Annerose; Beyersdorf, Friedhelm; Sax, Hugo; Böttger, Erik C; Weber, Rainer; van Ingen, Jakko; Wagner, Dirk; Hasse, Barbara

    2015-10-21

    We identified 10 patients with disseminated Mycobacterium chimaera infections subsequent to open-heart surgery at three European Hospitals. Infections originated from the heater-cooler unit of the heart-lung machine. Here we describe clinical aspects and treatment course of this novel clinical entity. Interdisciplinary care and follow-up of all patients was documented by the study team. Patients' characteristics, clinical manifestations, microbiological findings, and therapeutic measures including surgical reinterventions were reviewed and treatment outcomes are described. The 10 patients comprise a 1-year-old child and nine adults with a median age of 61 years (range 36-76 years). The median duration from cardiac surgery to diagnosis was 21 (range 5-40) months. All patients had prosthetic material-associated infections with either prosthetic valve endocarditis, aortic graft infection, myocarditis, or infection of the prosthetic material following banding of the pulmonary artery. Extracardiac manifestations preceded cardiovascular disease in some cases. Despite targeted antimicrobial therapy, M. chimaera infection required cardiosurgical reinterventions in eight patients. Six out of 10 patients experienced breakthrough infections, of which four were fatal. Three patients are in a post-treatment monitoring period. Healthcare-associated infections due to M. chimaera occurred in patients subsequent to cardiac surgery with extracorporeal circulation and implantation of prosthetic material. Infections became clinically apparent after a time lag of months to years. Mycobacterium chimaera infections are easily missed by routine bacterial diagnostics and outcome is poor despite long-term antimycobacterial therapy, probably because biofilm formation hinders eradication of pathogens. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  16. The influence of prototype testing in three-dimensional aortic models on fenestrated endograft design.

    Science.gov (United States)

    Taher, Fadi; Falkensammer, Juergen; McCarte, Jamie; Strassegger, Johann; Uhlmann, Miriam; Schuch, Philipp; Assadian, Afshin

    2017-06-01

    The fenestrated Anaconda endograft (Vascutek/Terumo, Inchinnan, UK) is intended for the treatment of abdominal aortic aneurysms with an insufficient infrarenal landing zone. The endografts are custom-made with use of high-resolution, 1-mm-slice computed tomography angiography images. For every case, a nonsterile prototype and a three-dimensional (3D) model of the patient's aorta are constructed to allow the engineers as well as the physician to test-implant the device and to review the fit of the graft. The aim of this investigation was to assess the impact of 3D model construction and prototype testing on the design of the final sterile endograft. A prospectively held database on fenestrated endovascular aortic repair patients treated at a single institution was completed with data from the Vascutek engineers' prototype test results as well as the product request forms. Changes to endograft design based on prototype testing were assessed and are reported for all procedures. Between April 1, 2013, and August 18, 2015, 60 fenestrated Anaconda devices were implanted. Through prototype testing, engineers were able to identify and report potential risks to technical success related to use of the custom device for the respective patient. Theoretical concerns about endograft fit in the rigid model were expressed in 51 cases (85.0%), and the engineers suggested potential changes to the design of 21 grafts (35.0%). Thirteen cases (21.7%) were eventually modified after the surgeon's testing of the prototype. A second prototype was ordered in three cases (5.0%) because of extensive changes to endograft design, such as inclusion of an additional fenestration. Technical success rates were comparable for grafts that showed a perfect fit from the beginning and cases in which prototype testing resulted in a modification of graft design. Planning and construction of fenestrated endografts for complex aortic anatomies where exact fit and positioning of the graft are paramount to

  17. Systematic review and meta-analysis of surgical outcomes in Marfan patients undergoing aortic root surgery by composite-valve graft or valve sparing root replacement.

    Science.gov (United States)

    Flynn, Campbell D; Tian, David H; Wilson-Smith, Ashley; David, Tirone; Matalanis, George; Misfeld, Martin; Mastrobuoni, Stefano; El Khoury, Gebrine; Yan, Tristan D

    2017-11-01

    A major, life-limiting feature of Marfan syndrome (MFS) is the presence of aneurysmal disease. Cardiovascular intervention has dramatically improved the life expectancy of Marfan patients. Traditionally, the management of aortic root disease has been undertaken with composite-valve graft replacing the aortic valve and proximal aorta; more recently, valve sparing procedures have been developed to avoid the need for anticoagulation. This meta-analysis assesses the important surgical outcomes of the two surgical techniques. A systematic review and meta-analysis of 23 studies reporting the outcomes of aortic root surgery in Marfan patients with data extracted for outcomes of early and late mortality, thromboembolic events, late bleeding complications and surgical reintervention rates. The outcomes of 2,976 Marfan patients undergoing aortic root surgery were analysed, 1,624 patients were treated with composite valve graft (CVG) and 1,352 patients were treated with valve sparing root replacement (VSRR). When compared against CVG, VSRR was associated with reduced risk of thromboembolism (OR =0.32; 95% CI, 0.16-0.62, P=0.0008), late hemorrhagic complications (OR =0.18; 95% CI, 0.07-0.45; P=0.0003) and endocarditis (OR =0.27; 95% CI, 0.10-0.68; P=0.006). Importantly there was no significant difference in reintervention rates between VSRR and CVG (OR =0.89; 95% CI, 0.35-2.24; P=0.80). There is an increasing body of evidence that VSRR can be reliably performed in Marfan patients, resulting in a durable repair with no increased risk of re-operation compared to CVG, thus avoiding the need for systemic anticoagulation in selected patients.

  18. Development of a New Intravascular Low-Profile Device for Exclusion of Aortic Aneurysm: An Experimental Pilot Study

    International Nuclear Information System (INIS)

    Strecker, Ernst-Peter; Haberstroh, Joerg; Boos, Irene; Metz, Stephan; Langer, Mathias; Moliner, Manuel Maynar

    2004-01-01

    Purpose: To present a new intravascular device for the treatment of aorto-iliac aneurysms. Methods: This new device was tested in five dogs with abdominal aortic aneurysm created experimentally by overdilation of a balloon-expandable stent with a 16 or 18 mm wide PTA balloon catheter. The design of the device is based on a self-expanding aortic stent which consists of two stretchable circular frames filled with a textile Dacron mesh membrane that is suspended horizontally into the infrarenal abdominal aorta proximally to the aneurysm. The frames are part of a preshaped double helical structure that is introduced longitudinally through a catheter in a parallel fashion and forming the desired shape at the vessel site to be occluded. Two iliac stent-grafts are introduced in a low-profile status through the membrane sealing the aneurysm sac and holding the stent-grafts in place. After stent-graft expansion, a new bifurcation located more proximally than the natural one is created. The follow-up of the dogs was performed clinically and angiographically, and specimens were evaluated histomorphologically. Results: The membrane device can be introduced through a 9 Fr vascular sheath. Technical success was achieved in four of five dogs. Nine of ten stent-grafts could be fixed securely within the membrane, thus preventing dislocation. Aneurysms were excluded immediately, and blood flow to the external iliac arteries was restored by the stent-grafts. At 6-9 months follow-up of technically successful implanted devices, there were no endoleaks, no migration, no stenoses at contact sites between the implant material and vascular wall, and no stenosis or occlusion of the stent-grafts. At microscopic evaluation, the interspace between the membranes was filled with thrombotic material, thus ensuring exclusion of the aneurysm. Conclusion: This new device was found to be flexible, low profile and useful in excluding abdominal aortic aneurysm in the experimental setting

  19. Histologic Assessment of Drug-Eluting Grafts Related to Implantation Site

    Directory of Open Access Journals (Sweden)

    Jean-Christophe Tille

    2016-02-01

    Full Text Available Drug-eluting vascular prostheses represent a new direction in vascular surgery to reduce early thrombosis and late intimal hyperplasia for small calibre grafts. Subcutaneous implantation in rats is a rapid and cost-effective screening model to assess the drug-elution effect and could, to some extent, be useful to forecast results for vascular prostheses. We compared biological and histological responses to scaffolds in different implantation sites. Polycaprolactone (PCL, paclitaxel-loaded PCL (PCL-PTX and dexamethasone-loaded PCL (PCL-DXM electrospun scaffolds were implanted subcutaneously and in an infrarenal abdominal aortic model in rats for up to 12 weeks. At the conclusion of the study, a histological analysis was performed. Cellular graft invasion revealed differences in the progression of cellular infiltration between PCL-PTX and PCL/PCL-DXM groups in both models. Cell infiltration increased over time in the aortic model compared to the subcutaneous model for all groups. Cell counting revealed major differences in fibroblast, macrophage and giant cell graft colonisation in all groups and models over time. Macrophages and giant cells increased in the PCL aortic model; whereas in the subcutaneous model these cell types increased only after three weeks or even decreased in the drug-eluting PCL groups. Other major findings were observed only in the aortic replacement such as extracellular matrix deposition and neo-angiogenesis. The subcutaneous implant model can be used for screening, especially when drug-eluting effects are studied. However, major histological differences were observed in cell type reaction and depth of cell penetration compared to the aortic model. Our results demonstrate that the implantation site is a critical determinant of the biological response.

  20. Comparison of long-term clinical outcome between patients with chronic versus acute type B aortic dissection treated by implantation of a stent graft: a single-center report

    Directory of Open Access Journals (Sweden)

    Chen SL

    2013-04-01

    Full Text Available Shao-Liang Chen, Jian-Cheng Zhu, Xiao-Bo Li, Fei Ye, Jun-Jie Zhang, Zhi-Zhong Liu, Nai-Liang Tian, Song Lin, Cheng-Yu Lv Nanjing First Hospital, Nanjing Medical University, Nanjing, People's Republic of China Background: Stent grafting for treatment of type B aortic dissection has been extensively used. However, the difference in the long-term clinical outcome between patients with chronic versus acute type B aortic dissection remains unknown. This study aimed to analyze the difference in long-term clinical outcome after endovascular repair for patients with chronic (93% complete false-lumen thrombosis. Untreated tear and type I endoleak were predictors of clinical events during follow-up. Conclusion: Comparable long-term clinical results were achieved in patients with chronic or acute type B aortic dissection after implantation of a stent graft. Keywords: aortic dissection, endovascular repair, procedure-related events, propensity score matching

  1. Perfect and least invasive sealing technique on the lesser curvature of the aortic arch: application of a novel stent graft to an aneurysm developing on a postoperative ductus arteriosus.

    Science.gov (United States)

    Soeda, Takeshi; Yokoi, Yoshihiko; Yuri, Koichi; Saito, Yuuhei; Setozaki, Shuji; Harada, Hisao

    2013-01-01

    A 78-year-old woman who underwent an operation for a patent ductus arteriosus (PDA) about thirty years ago developed an aneurysm on the aortic side of the remnant ductal tissue. To avoid risky, open surgery, we performed endovascular aortic therapy using a novel stent graft (SG), which was pre-curved, fenestrated and custom-made type. This graft was designed to configure to the patient's whole aortic arch anatomy, and was capable of accurately adjusting its fenestrations to the arch branch orifices during the procedure. The operation was successful, and the patient was discharged uneventfully on 16th postoperative day. The advantage of this fenestrated SG is close sealing, especially over the lesser curvature of the arch. This device could be a simple and effective option to deal with an otherwise normal aortic arch with such a ductus-related localized lesion.

  2. Predictors of inotrope use in patients undergoing concomitant coronary artery bypass graft (CABG and aortic valve replacement (AVR surgeries at separation from cardiopulmonary bypass (CPB

    Directory of Open Access Journals (Sweden)

    Nelson William B

    2009-06-01

    Full Text Available Abstract Background Left ventricular dysfunction is common after coronary artery bypass graft and valve replacement surgeries and is often treated with inotropic drugs to maintain adequate hemodynamic status. In this study, we aimed to identify the demographic, clinical, laboratory, echocardiographic and hemodynamic factors that are associated with use of inotropic drugs in patients undergoing concomitant coronary artery bypass graft and aortic valve replacement surgery. Methods The study included 97 patients who had undergone concomitant coronary artery bypass graft and aortic valve replacement at Regions Hospital, University of Minnesota Medical School from January 2006 to December 2008. All data were collected retrospectively after reviewing electronic medical records. Inotropic support was defined as the use of dopamine [greater than or equal to] 5 ug/kg/min; any dose of epinephrine, norepinephrine, dobutamine, and milrinone at the separation from cardiopulmonary bypass. Results Inotropic support was used in a total of 50 patients (52% at the separation from cardiopulmonary bypass. Average age of the patients requiring inotropic support was 72.2 +/- 8.8 years. The study identified four significant, independent predictors of inotrope use: (1 Cardiac index [less than or equal to]2.5 L/min/m2, (2 LVEDP [greater than or equal to] 20 mm Hg, (3 LVEF [less than or equal to]40%, and (4 CKD stage 3 to 5. Conclusion We identified four independent risk factors for postoperative use of inotropic support in patients undergoing concomitant coronary artery bypass graft and arotic valve replacement surgery at the separation from cardiopulmonary bypass. The study results will be helpful to prospectively identify patients who will likely to require inotropic support at the separation from cardiopulmonary bypass.

  3. Early and mid-term outcomes of combined aortic valve replacement and coronary artery bypass grafting in elderly patients.

    Science.gov (United States)

    Fukui, Toshihiro; Bando, Ko; Tanaka, Sachiko; Uchimuro, Tomoya; Tabata, Minoru; Takanashi, Shuichiro

    2014-02-01

    Although the number of elderly patients undergoing combined aortic valve replacement (AVR) and coronary artery bypass grafting (CABG) is increasing, the early and mid-term outcomes of this combined procedure remain to be determined. We sought to elucidate the early and mid-term outcomes of elderly (≥75 years) vs non-elderly (non-elderly patients (40.2%; Non-elderly group) with a mean age of 67.3±5.8 years. Early and mid-term outcomes were compared, and multivariate analyses were performed to determine the risk factors for morbidity and mortality. The mean follow-up times were 33.1±21.7 and 37.4±22.2 months in the Elderly and Non-elderly groups, respectively. The mean number of anastomoses and the frequency of use of the internal thoracic artery were similar between the two groups. The use of a mechanical valve was less frequent in the Elderly group than in the Non-elderly group (11.6 vs 60.6%, PNon-elderly groups had similar rates of operative death (1.9 vs 1.0%, P=0.651), early stroke (2.6 vs 1.0%, P=0.651), 5-year overall survival (83.1±4.8 vs 87.2±5.2%, P=0.358), 5-year freedom from cardiac death (92.3±2.7 vs 94.8±3.4%, P=0.570) and 5-year freedom from stroke (94.0±2.6 vs 99.0±1.0%, P=0.097). Cox proportional hazards analyses identified diabetes, creatinine level and EuroSCORE II, but not age, as independent predictors of overall mortality rate. Early and mid-term outcomes of combined AVR and CABG were similar between elderly and non-elderly patients. Older age was not a risk factor for mortality in patients undergoing combined AVR plus CABG, and this procedure should be recommended in properly selected elderly patients.

  4. Rupture of an abdominal aortic aneurysm in a young man with Marfan Syndrome

    DEFF Research Database (Denmark)

    Pedersen, Maria Weinkouff; Huynh, Khiem Dinh; Baandrup, Ulrik Thorngren

    2018-01-01

    Abdominal aortic aneurysms are very rare in Marfan syndrome. We present a case with a young non-smoking and normotensive male with Marfan syndrome, who developed an infrarenal abdominal aortic aneurysm that presented with rupture to the retroperitoneal cavity causing life-threatening bleeding shock...

  5. Intra-operative cone beam computed tomography can help avoid reinterventions and reduce CT follow up after infrarenal EVAR.

    Science.gov (United States)

    Törnqvist, P; Dias, N; Sonesson, B; Kristmundsson, T; Resch, T

    2015-04-01

    Re-interventions after endovascular abdominal aortic aneurysm repair (EVAR) are common and therefore a strict imaging follow up protocol is required. The purpose of this study was to evaluate whether cone beam computed tomography (CBCT) can detect intra-operative complications and to compare this with angiography and the 1 month CT follow up (computed tomography angiography [CTA]). Fifty-one patients (44 men) were enrolled in a prospective trial. Patients underwent completion angiography and CBCT during infrarenal EVAR. Contrast was used except when pre-operative renal insufficiency was present or if the maximum contrast dose threshold was reached. CBCT reconstruction included the top of the stent graft to the iliac bifurcation. Endoleaks, kinks, or compressions were recorded. CBCT was technically successful in all patients. Twelve endoleaks were detected on completion digital subtraction angiography (CA). CBCT detected 4/5 type 1 endoleaks, but only one type 2 endoleak. CTA identified eight type 2 endoleaks and one residual type I endoleak. Two cases of stent compression were seen on CA. CBCT revealed five stent compressions and one kink, which resulted in four intra-operative adjunctive manoeuvres. CTA identified all cases of kinks or compressions that were left untreated. Two of them were corrected later. No additional kinks/compressions were found on CTA. Groin closure consisted of 78 fascia sutures, nine cut downs, and 11 percutaneous sutures. Seven femoral artery pseudoaneurysms (<1 cm) were detected on CTA, but no intervention was needed. CA is better than CBCT in detecting and categorizing endoleaks but CBCT (with or without contrast) is better than CA for detection of kinks or stentgraft compression. CTA plus CBCT identified all significant complications noted on the 1 month follow up CTA. The use of intra-operative CA and CBCT could replace early CTA after standard EVAR thus reducing overall radiation and contrast use. Technical development might further

  6. Aortography following subdiaphragmal aortic biopsy

    International Nuclear Information System (INIS)

    Schimmler, J.

    1982-01-01

    A juxtaposition of the subdiaphragmal and infrarenal translumbar aortic biopsy sites showed decisive advantages in favour of the higher site: a more stable position because of better anatomic fixation and rarer incidence of vascular alterations, a wider vascular lumen. Disadvantages lie in the fact that the large visceral arteries (especially Tr. coeliacus) branch off nearly and in the close anatomic relationship to large abdominal organs and the thoracal region. Evaluation of the radiographical image of the vascular tree after subdiaphragmal aortic biopsy showed an average 82% of the vessels to the area of the Knees to be assessable (renal arteries approximately 93%, popliteal arteries approximately 70%). Beyong, the method proved unsatisfactory: 52% of the vessels could not, or not safety, be evaluated. A relatively broad spectrum of indications by comparison with transfemoral catheter aortography had no influence on the rate of complications with reference to either method. A comparison of the topographic conditions shows the need for even more scrupulons observation of the technique in subdiaphragmal biopsy than in the infrarenal one. To sum up the results obtained, subdiaphregmal translumbar aortography is to be preferred to the infrarenal one where transfemoral catheter aortography is contra-indicated, within the limits mentioned. (orig.) [de

  7. Induction of autoimmune abdominal aortic aneurysm in pigs

    DEFF Research Database (Denmark)

    Riber, Sara Schødt; Ali, Mulham; Bergseth, Sara Hveding

    2017-01-01

    of this study was to develop a large animal model for abdominal aortic aneurysm induction through autoimmunity by performing sheep-to-pig xenotransplantation. Methods Six pigs underwent a xenotransplantation procedure where the infrarenal porcine aorta was replaced by a decellularized sheep aorta...

  8. Coronary artery bypass grafting associated to aortic valve replacement in the elderly: survival and quality of life

    Directory of Open Access Journals (Sweden)

    Vicchio Mariano

    2012-02-01

    Full Text Available Abstract Myocardial ischemia is often associated to aortic valve stenosis in the elderly. Aim of this study was to evaluate the impact on survival and quality of life of CABG associated to aortic valve replacement in the septuagenarians and octogenarians. Between January 1991 and January 2010, 520 patients ageing > 70 years underwent aortic valve replacement with a mechanical prosthesis in two Institutions. They were divided into 2 groups: Group A included 406 patients undergoing isolated aortic valve replacement; Group B 114 patients receiving aortic valve replacement and CABG. A comparative analysis of long-term survival and quality of life (SF-36 test was performed. Mean age was 74.2 ± 3.6 years (74.3 ± 3.6 in Group A, 74 ± 3.3 in Group B; p = 0.33. Hospital mortality was 9.5% (46 patients. Twenty-nine (7.8% in Group A and 17 in Group B (15.2%(p = 0.019. Actuarial survival was 88.5% ± 0.015 at 1 year, 81.9% ± 0.02 at 5 years, 76.6% ± 0.032 at 10 and 57.3 ± 0.1 at 15 years. Ten-year survival was 77% ± 0.034 in Group A and 77.8% ± 0.045 in Group B (p = 0.2. Multivariate analysis did not reveal associated CABG as a predictor of long term mortality. The scores obtained in the SF-36 test were similar in the two groups and significantly higher than those of the general population matched for country, age and sex (p Associated CABG determines a significant increase of hospital mortality in the elderly undergoing aortic valve replacement. Survivors did not show differences in long-term outcome and quality of life according to the presence of associated CABG.

  9. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms.

    Science.gov (United States)

    Tricarico, Rosamaria; He, Yong; Laquian, Liza; Scali, Salvatore T; Tran-Son-Tay, Roger; Beck, Adam W; Berceli, Scott A

    2017-12-01

    To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area 25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.

  10. Aortic valve replacement with or without coronary artery bypass graft surgery: the risk of surgery in patients > or =80 years old.

    Science.gov (United States)

    Maslow, Andrew; Casey, Paula; Poppas, Athena; Schwartz, Carl; Singh, Arun

    2010-02-01

    The purpose of this study was to evaluate the outcomes for elderly (> or =80 years) patients undergoing aortic valve replacement (AVR) with or without coronary artery bypass graft surgery (AVR/CABG). The authors hypothesized that the mortalities of AVR and AVR/CABG are lower than that predicted by published risk scores. A retrospective analysis of data from a single-hospital database. Single tertiary care, private practice. Consecutive patients undergoing AVR or AVR/CABG. Two hundred sixty-one elderly (> or =80 years) patients undergoing isolated AVR (145) or AVR/CABG (116) were evaluated. The majority (94.6%) underwent AVR for aortic valve stenosis. Outcomes were recorded and compared between the 2 surgical procedures with predicted mortalities based on published risk assessment scoring systems. The overall short-term mortality for the elderly group was 6.1% (AVR 5.5% and AVR/CABG 6.9%). The median long-term survival was 6.8 years. There were no significant differences in either morbidity or mortality between the AVR and AVR/CABG groups. Although predicted mortalities were similar for each surgical procedure, they overestimated observed outcome by up to 4-fold. Short- and long-term mortality was low for this group of elderly patients undergoing AVR or AVR/CABG and not significantly different between the 2 surgical groups. Predicted outcomes were worse than that observed, consistent with the hypothesis, and supportive of a more aggressive surgical treatment for aortic valve disease in the elderly patient. Copyright 2010 Elsevier Inc. All rights reserved.

  11. Spinal arterial anatomy and risk factors for lower extremity weakness following endovascular thoracoabdominal aortic aneurysm repair with branched stent-grafts.

    Science.gov (United States)

    Chang, Catherine K; Chuter, Timothy A M; Reilly, Linda M; Ota, Maile K; Furtado, Andre; Bucci, Monica; Wintermark, Max; Hiramoto, Jade S

    2008-06-01

    To evaluate spinal arterial anatomy and identify risk factors for lower extremity weakness (LEW) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. A retrospective review was conducted of 37 patients (27 men; mean age 74.8+/-7.1 years, range 58-86) undergoing endovascular TAAA repair with branched stent-grafts at a single academic institution from July 2005 to December 2007. Data were collected on preoperative comorbidities, duration of operation, blood loss, type of anesthesia, extent of aortic coverage, blood pressure, cerebrospinal fluid (CSF) pressure and drainage, and postoperative development of LEW. Pre- and postoperative contrast-enhanced computed tomographic angiograms (CTA) in a 26-patient subset were analyzed to evaluate the number of patent intercostal and lumbar arteries before and after repair. All patients were neurologically intact at the end of the operation. Seven (19%) patients developed LEW postoperatively: 6 perioperatively and 1 after discharge. LEW was associated with postoperative hypotension, internal iliac artery (IIA) occlusion, and fewer patent segmental arteries on preoperative CTA. Lowest mean systolic blood pressure was segmental arteries in patients with or without LEW. Endovascular TAAA repair inevitably occludes direct inflow to lumbar and intercostal arteries. The distal segments of these arteries to the spine, however, are seen to remain patent through collaterals. Measures to preserve collateral pathways and increase perfusion pressure may help prevent or treat LEW.

  12. Traumatic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Brianna Miner

    2016-09-01

    Full Text Available History of present illness: A 48-year-old male with unknown past medical history presents as a trauma after being hit by a car traveling approximately 25 miles per hour. On initial presentation, the patient is confused, combative, and not answering questions appropriately. The patient is hypotensive with a blood pressure of 68/40 and a heart rate of 50 beats per minute, with oxygen saturation at 96% on room air. FAST scan is positive for fluid in Morrison’s pouch, splenorenal space, and pericardial space. Significant findings: The initial chest x-ray showed an abnormal superior mediastinal contour (blue line, suggestive of a possible aortic injury. The CT angiogram showed extensive circumferential irregularity and outpouching of the distal aortic arch (red arrows compatible with aortic transection. In addition, there was a circumferential intramural hematoma, which extended through the descending aorta to the proximal infrarenal abdominal aorta (green arrow. There was also an extensive surrounding mediastinal hematoma extending around the descending aorta and supraaortic branches (purple arrows. Discussion: Traumatic aortic injury is a life-threatening event. The incidence of blunt thoracic aortic injury is low, between 1 to 2 percent of those patients with blunt thoracic trauma.1 However, approximately 80% of patients with traumatic aortic injury die at the scene.2 Therefore it is imperative to diagnose traumatic aortic injury in a timely fashion. The diagnosis can be difficult due to the non-specific signs and symptoms and other distracting injuries. Clinical suspicion should be based on the mechanism of the injury and the hemodynamic status of the patient. In any patient with blunt or penetrating trauma to the chest that is hemodynamically unstable, traumatic aortic injury should be on the differential. Chest x-ray can be used as a screening tool. A normal chest x-ray has a negative predictive value of approximately 97%. CTA chest is the

  13. Concepts to optimize stent-grafting of abdominal aortic aneurysms based on results of experimental studies; Konzepte zur Optimierung der Stentgraftversorgung von Bauchaortenaneurysmen auf der Basis tierexperimenteller Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Chavan, A.; Kirchhoff, T.; Baus, S.; Galanski, M. [Medizinische Hochschule Hannover (Germany). Abt. Diagnostische Radiologie 1; Pichlmaier, M. [Medizinische Hochschule Hannover (Germany). Leibniz Forschungslab. fuer Biotechnologie und Kuenstliche Organe an der Klinik fuer Thorax-, Herz- und Gefaesschirurgie

    2001-08-01

    Purpose. In the endoluminal therapy of abdominal aortic aneurysms, a short proximal aneurysm neck, endoleaks and the large size and stiffness of the introducer systems are responsible for many of the complications and sub-optimal outcomes. The purpose of the present review article is to to suggest strategies to minimize these complications based on the results of experimental studies in animals. Material and methods. After implanting various types of stents across the renal artery origins, the functional and morphological changes in the kidneys and renal vessels were studied by various authors. In order to prevent progressive widening of the proximal aneurysmal neck and graft dislocation, Sonesson et al. performed a laparoscopic banding around the proximal neck in pigs. To study the effects of endoleaks, Marty, Schurink and Pitton carried out pressure measurements in experimental aneurysms with and without endoleaks. Sakaguchi and Pavcnik developed the 'Twin-tube endografts' (TTEG) and the 'Bifurcated drum occluder endografts' (BDOEG) and tested them in dogs. Results. Up to 3 months after suprarenal stent placement, Chavan et al. detected no significant fall in the mean inulin clearance in sheep (140{+-}46 ml/min before, 137{+-}58 ml/min after). Nasim et al. and Malina et al. reported similar observations with respect to renal function. Suprarenal fixation may result in isolated thrombotic occlusions of the renal arteries and microinfarcts in the kidneys. Mean aortic diameters at the level of banding were significantly smaller in the animals with aortic banding as opposed to those in the control group without banding (8 mm vs 11 mm, p=0.004). The banding caused a secure proximal fixation of the stent-graft. Persistent endoleaks resulted in significantly higher intraaneurysmal pressures. Although the TTEG and the BDOEG stent-grafts required smaller sheaths, occlusions were observed in 8% (TTEG) and 60% (BDOEG) of the graft limbs. (orig.) [German

  14. Textural features of 18F-fluorodeoxyglucose positron emission tomography scanning in diagnosing aortic prosthetic graft infection

    NARCIS (Netherlands)

    Saleem, Ben R.; Beukinga, Roelof J.; Boellaard, Ronald; Glaudemans, Andor W.J.M.; Reijnen, Michel M.P.J.; Zeebregts, Clark J.; Slart, Riemer H.J.A.

    2017-01-01

    Background: The clinical problem in suspected aortoiliac graft infection (AGI) is to obtain proof of infection. Although 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography scanning (PET) has been suggested to play a pivotal role, an evidence-based interpretation is lacking. The objective

  15. Textural features of (18)F-fluorodeoxyglucose positron emission tomography scanning in diagnosing aortic prosthetic graft infection

    NARCIS (Netherlands)

    Saleem, Ben R; Beukinga, Roelof J.; Boellaard, Ronald; Glaudemans, Andor W J M; Reijnen, Michel M P J; Zeebregts, Clark J; Slart, Riemer H J A

    BACKGROUND: The clinical problem in suspected aortoiliac graft infection (AGI) is to obtain proof of infection. Although (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography scanning (PET) has been suggested to play a pivotal role, an evidence-based interpretation is lacking. The

  16. [Revascularization surgery of an anuric solitary kidney using the left colic artery as a free graft].

    Science.gov (United States)

    da Gama, A Dinis; Nunes, J Silva; Cunha e Sá, Diogo; Pedro, Luís Mendes

    2003-01-01

    The thrombotic occlusion of one renal artery may become completely asymptomatic, due to the functionality of the contralateral kidney. However, in rare circumstances, such is the case of individuals with a solitary kidney, a situation of anuria and acute renal failure may constitute the main presentation of the condition. The authors report the clinical case of a 43 year old male patient, with the previous diagnosis of an infrarenal aortic occlusion and a single left kidney, who developed a thrombotic occlusion of the renal artery, with anuria and acute renal failure. The patient underwent an emergency revascularization procedure, consisting in the implantation of a prosthetic bypass graft from the superceliac aorta to the renal artery, with immediate recovery of the diuresis and renal function. Seventeen months later as a consequence of an anastomotic hyperplasia, an occlusion of the bypass graft occurred, again with anuria and acute renal failure. The patient was reoperated on and due to the inadequacy of both saphenous veins to be used as the material of choice for the revascularization procedure, a redundant segment of the left colic artery (Riolan's arcade) was removed and used as an interposition graft, from the middle colic artery to the renal artery, followed by an immediate restoration of diuresis and renal function. The singular and recurrent character of this clinical condition and the utilization of an original, eventually unique and well succeeded revascularization procedure, prompted its presentation and divulgation.

  17. Primary Self-Expandable Nitinol Stent Placement in Focal Lesions of Infrarenal Abdominal Aorta: Long Term Results

    International Nuclear Information System (INIS)

    Lastovickova, Jarmila; Peregrin, Jan H.

    2008-01-01

    Purpose. To evaluate the technical and clinical success, safety and long term results of percutaneous transluminal angioplasty/self-expandable nitinol stent placement of infrarenal abdominal aorta focal lesions. Materials and Methods. Eighteen patients underwent PTA of focal atherosclerotic occlusive disease of distal abdominal aorta. Two symptomatic occlusions and 16 stenoses in 10 male and 8 female patients (mean age 68.2 years) were treated with primary self-expandable nitinol stent placement. Results. Primary self-expandable nitinol stent placement was technically successful in all 18 procedures; clinical success was achieved in 100% of patients. No complications associated with the procedure occurred. During the 49.4 months of mean follow up (range 3-96, 4 months) all treated aortic segments remained patent. Conclusions. Endovascular treatment (primary self-expandable nitinol stent placement) of focal atherosclerotic lesions of distal abdominal aorta is a safe method with excellent primary technical and clinical success rates and favourable Long term results

  18. Takayasu arteritis with middle aortic syndrome and mesenteric ischemia treated by aortic stenting

    Directory of Open Access Journals (Sweden)

    Sarah Morrissey, MD, MA, FRCSC

    2017-09-01

    Full Text Available A 48-year-old woman suffering from Takayasu arteritis presented with middle aortic syndrome consisting of abdominal pain, refractory hypertension with pulmonary edema and pleural effusions, and lower limb ischemia. She failed to improve with high-dose steroid therapy and underwent endovascular stenting of two severe stenoses in the supraceliac and infrarenal aorta. Her symptoms resolved and hypertension improved after the procedure.

  19. The effect of transluminal stent-graft placement on blood flow of abdominal branch vessels in type B aortic dissection

    International Nuclear Information System (INIS)

    Huang Lianjun; Yang Jian; Yu Feicheng; Sun Lizhong; Zhu Junming; Zhang Yan; Jiang Shiliang

    2005-01-01

    Objective: To evaluate the effect of TSGP on blood flow of abdominal branch vessels of Type B dissection. Methods: Thirty-five patients with type B aortic dissection underwent TSGP. The blood flow of abdominal branch vessels was analyzed via EBCT, MRI, and DSA before and after procedure. Results: A total of 140 important vessels from abdominal aorta in 35 patients, including celiac artery, SMA, right and left renal arteries were analyzed via EBCT, MRI, and DSA. 58 branches were affected by dissection, of which 14 (10% ) were dynamic impairment; and 44 (31.4%) were static impairment. After TSGP, the blood flow of impaired branches all showed improvement at different degrees, no post-operative ischemic complications occurred. Conclusion: TSGP could improve the blood flow immediately not only the dynamic but also the static ischemia of abdominal aorta branch vessels caused by type B aortic dissection. Further study is still need to observe the mid-term and long-term effect of TSGP. (authors)

  20. Extra-anatomic bypass for recurrent abdominal aortic and renal in-stent stenoses following radiotherapy for neuroblastoma.

    Science.gov (United States)

    Luehr, Maximilian; Siepe, Matthias; Beyersdorf, Friedhelm; Schlensak, Christian

    2009-04-01

    We describe the case of an 11-year-old girl with an abdominal neuroblastoma which was operated and intraoperatively irradiated nine years ago. After six years, she developed stenoses of the infrarenal abdominal aorta and both renal arteries. Initial treatment of the stenosed vessels comprised endovascular balloon dilatations and repeated stent-graft implantations, including drug eluting stents. However, severe in-stent stenoses occurred during follow-up and the girl developed acute renal failure. Open surgery was performed with two extra-anatomic bypasses, a thoracic-to-abdominal aortic bypass and a left iliac-to-renal bypass, on an urgent basis. The postoperative course was uneventful and the patient was discharged home two weeks after the operation with full recovery of renal function. We conclude that endovascular stent-graft placement in children can only be a palliative treatment due to outgrowing of the stent-graft and the potential risk of re-stenosis, especially after a history of irradiation. Vascular surgery with placement of extra-anatomic bypasses will provide a definite treatment.

  1. Unusual Congenital Aortic Anomaly with Rare Common Celiamesenteric Trunk Variation: MR Angiography and Digital Substraction Angiography Findings

    International Nuclear Information System (INIS)

    Tosun, Ozgur; Sanlidilek, Umman; Cetin, Huseyin; Ozdemir, Ozcan; Kurt, Aydin; Sakarya, Mehmet Emin; Tas, Ismet

    2007-01-01

    Magnetic resonance angiography and digital substraction angiography (DSA) findings in a case with a rare congenital thoracoabdominal aortic hypoplasia and common celiamesenteric trunk variation with occlusion of infrarenal abdominal aorta are described here. To our knowledge, this aortic anomaly has not been previously described in the English literature. DSA is the optimum imaging modality for determination of aortic hypoplasia, associated vascular malformations, collateral vessels, and direction of flow within vessels

  2. Blunt injury of the infrarenal inferior vena cava — imaging and ...

    African Journals Online (AJOL)

    Blunt injury of the infrarenal inferior vena cava — imaging and conservative management. Ian C Duncan, Basil J Sher, Leslie M Fingleson. Abstract. Isolated rupture of the infrarenal segment of the inferior vena cava due to blunt trauma is relatively rare. It may be missed clinically and even diagnostic peritoneal lavage may ...

  3. Factors associated with pulmonary dysfunction in patients undergoing coronary artery bypass graft surgery with use of intra-aortic balloon pump.

    Science.gov (United States)

    Amaral Gonçalves Fusatto, Helena; Castilho de Figueiredo, Luciana; Ragonete Dos Anjos Agostini, Ana Paula; Sibinelli, Melissa; Dragosavac, Desanka

    2018-01-01

    The aim of this study was to identify pulmonary dysfunction and factors associated with prolonged mechanical ventilation, hospital stay, weaning failure and mortality in patients undergoing coronary artery bypass grafting with use of intra-aortic balloon pump (IABP). This observational study analyzed respiratory, surgical, clinical and demographic variables and related them to outcomes. We analyzed 39 patients with a mean age of 61.2 years. Pulmonary dysfunction, characterized by mildly impaired gas exchange, was present from the immediate postoperative period to the third postoperative day. Mechanical ventilation time was influenced by the use of IABP and PaO2/FiO2, female gender and smoking. Intensive care unit (ICU) stay was influenced by APACHE II score and use of IABP. Mortality was strongly influenced by APACHE II score, followed by weaning failure. Pulmonary dysfunction was present from the first to the third postoperative day. Mechanical ventilation time was influenced by female gender, smoking, duration of IABP use and PaO2/FiO2 on the first postoperative day. ICU stay was influenced by APACHE II score and duration of IABP. Mortality was influenced by APACHE II score, followed by weaning failure. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Effects of cilostazol and k-134 on reconstructive surgery using prosthetic grafts in the abdominal aorta of beagle dogs.

    Science.gov (United States)

    Inoue, Yoshinori; Sugano, Norihide; Jibiki, Masatoshi; Kudo, Toshifumi; Iwai, Takehisa

    2008-01-01

    Problems associated with prosthetic graft replacement are stenosis at the anastomosis site and thrombus formation on the inner surface. Cilostazol is known to have antiplatelet activity and inhibit vascular smooth muscle cell proliferation and neointima thickening. A cilostazol derivative, (-)-6-[3-[3-cyclopropyl-3-[(1R,2R)-2-hydroxycyclohexyl]ureido]-propoxy]-2-(1H)-quinolinone (K-134), has more potent anti-platelet activity and anti-neointimal thickening activity than cilostazol in the in-vitro platelet aggregation and in-vivo anti-hyperplastic activity assay. The aim of this study was to investigate effects of cilostazol and K-134 on thrombus formation and neointimal thickening at the site of prosthetic graft replacement. Beagle dogs underwent infrarenal abdominal aortic resection with straight Dacron graft replacement, which were allocated to the control, cilostazol, and K-134 groups. Two dogs were dead without confirming the cause of death. After 6 months, all dogs were necropsied. All prosthetic grafts were patent in each group. Ratios of red thrombus to prosthetic graft area were 0.3+/-6.4%, and 3.3+/-4.5% in the cilostazol and K-134 groups, respectively, which were significant different from that in the control group (24.4+/-16.8%). However, no clear difference was seen among the 3 groups with respect to neointimal thickness (control group, 0.70+/-0.13 mm; cilostazol group, 0.59+/-0.14 mm; K-134 group, 0.67+/-0.14 mm). Cilostazol and K-134 significantly inhibited thrombus formation on the inner surface of the prosthetic graft at 6 months after graft replacement. Neointimal thickening on the inner surface was slight even in control-group animals, and the effects of cilostazol and K-134 on such thickening were unclear.

  5. 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy.

    Science.gov (United States)

    Tam, Matthew D B S; Laycock, Stephen D; Brown, James R I; Jakeways, Matthew

    2013-12-01

    To describe rapid prototyping or 3-dimensional (3D) printing of aneurysms with complex neck anatomy to facilitate endovascular aneurysm repair (EVAR). A 75-year-old man had a 6.6-cm infrarenal aortic aneurysm that appeared on computed tomographic angiography to have a sharp neck angulation of ~90°. However, although the computed tomography (CT) data were analyzed using centerline of flow, the true neck length and relations of the ostial origins were difficult to determine. No multidisciplinary consensus could be reached as to which stent-graft to use owing to these borderline features of the neck anatomy. Based on past experience with rapid prototyping technology, a decision was taken to print a model of the aneurysm to aid in visualization of the neck anatomy. The CT data were segmented, processed, and converted into a stereolithographic format representing the lumen as a 3D volume, from which a full-sized replica was printed within 24 hours. The model demonstrated that the neck was adequate for stent-graft repair using the Aorfix device. Rapid prototyping of aortic aneurysms is feasible and can aid decision making and device delivery. Further work is required to test the value of 3D replicas in planning procedures and their impact on procedure time, radiation dose, and procedure cost.

  6. An Animal Model of Abdominal Aortic Aneurysm Created with Peritoneal Patch: Technique and Initial Results

    International Nuclear Information System (INIS)

    Maynar, Manuel; Qian Zhong; Hernandez, Javier; Sun Fei; Miguel, Carmen de; Crisostomo, Veronica; Uson, Jesus; Pineda, Luis-Fernando; Espinoza, Carmen G.; Castaneda, Wilfrido R.

    2003-01-01

    The purpose of this study was to develop an abdominal aortic aneurysm model that more closely resembles themorphology of human aneurysms with potential for further growth of the sac. An infrarenal abdominal aortic aneurysm (AAA) model was created with a double-layered peritoneal patch in 27 domestic swine. The patch,measuring in average from 6 to 12 cm in length and from 2 to 3 cm in width, was sutured to the edge of an aortotomy. Pre- and postsurgical digital subtraction aortograms (DSA) were obtained to document the appearance and dimensions of the aneurysm. All animals were followed with DSA for up to 5 months. Laparoscopic examination enhanced by the use of laparoscopic ultrasound was also carried out in 2 animals to assess the aneurysm at 30 and 60 days following surgery. Histological examination was performed on 4 animals. All the animals that underwent the surgical creation of the AAA survived the surgical procedure.Postsurgical DSA demonstrated the presence of the AAA in all animals,defined as more than 50% increase in diameter. The aneurysmal mean diameter increased from the baseline of 10.27 ± 1.24 to 16.69± 2.29 mm immediately after surgery, to 27.6 ± 6.59 mm at 14 days, 32.45 ± 8.76 mm at 30 days (p <0.01), and subsequently decreased to 25.98 ± 3.75 mm at 60 days. A total of 15 animals died of aneurysmal rupture that occurred more frequently in the long aneurysms (≥6 cm in length) than the short aneurysms (<6 cm in length) during the first 2 weeks after surgery(p < 0.05). No rupture occurred beyond 16 days after surgery. Four animals survived and underwent 60-day angiographic follow-up. Laparoscopic follow-up showed strong pulses, a reddish external appearance and undetectable suture lines on the aneurysmal wall. On pathology, the patches were well incorporated into the aortic wall, the luminal wall appeared almost completely endothelialized, and cellular and matrix proliferation were noted in the aneurysmal wall. A reproducible technique for the

  7. Six-Month Outcomes After High-Risk Coronary Artery Bypass Graft Surgery and Preoperative Intra-aortic Balloon Counterpulsation Use: An Inception Cohort Study.

    Science.gov (United States)

    Litton, Edward; Bass, Frances; Delaney, Anthony; Hillis, Graham; Marasco, Silvana; McGuinness, Shay; Myles, Paul S; Reid, Christopher M; Smith, Julian A

    2018-01-05

    To inform the design of a pivotal randomized controlled trial of prophylactic intra-aortic balloon counterpulsation (IABC) in patients undergoing coronary artery bypass graft (CABG) at high risk of postoperative low cardiac output syndrome (LCOS). Inception cohort study. A total of 13 established cardiac centers in Australia, Canada, New Zealand, and the United Kingdom. Adult patients were eligible for inclusion if they were listed for CABG surgery and had 2 or more LCOS risk factors (low ejection fraction, severe left main coronary artery disease, redo sternotomy, unstable angina). Outcomes of interest were a composite outcome of in-hospital mortality, postoperative acute myocardial infarction (AMI), acute kidney injury (AKI), or stroke as well as 6-month vital status and quality of life using the EuroQol 5-dimensional questionnaire (EQ5D). The study included 136 participants over a 29-month period. Overall, in-hospital and 6-month mortality occurred in 7 (5%) and 11 (8%) participants, respectively. The composite outcome occurred in 60 (44%). The mean increase in EQ5D summary index at 6 months was 0.10 (standard deviation 0.24, p = 0.01). Perioperative AMI, AKI, or stroke significantly decreased the odds of a clinically meaningful improvement in quality of life (odds ratio 0.32; 95% confidence interval 0.13-0.79; p = 0.014). Preoperative IABC was used in 39 participants and did not predict postoperative outcomes. The study identified a group of patients at risk of LCOS in whom CABG surgery was associated with a substantial burden of perioperative morbidity. Preoperative IABC use was variable, supporting the need for further research. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Italian Percutaneous EVAR (IPER) Registry: outcomes of 2381 percutaneous femoral access sites' closure for aortic stent-graft.

    Science.gov (United States)

    Pratesi, G; Barbante, M; Pulli, R; Fargion, A; Dorigo, W; Bisceglie, R; Ippoliti, A; Pratesi, C

    2015-12-01

    The aim of this paper was to report outcomes of endovascular aneurysm repair with percutaneous femoral access (pEVAR) using Prostar XL and Proglide closure systems (Abbot Vascular, Santa Clara, CA, USA), from the multicenter Italian Percutaneous EVAR (IPER) registry. Consecutive patients affected by aortic pathology treated by EVAR with percutaneous access (pEVAR) between January 2010 and December 2014 at seven Italian centers were enrolled in this multicenter registry. All the operators had an experience of at least 50 percutaneous femoral access procedures. Data were prospectively collected into a dedicated online database including patient's demographics, anatomical features, intra- and postoperative outcomes. A retrospective analysis was carried out to report intraoperative and 30-day technical success and access-related complication rate. Uni- and multivariate analyses were performed to identify factors potentially associated with an increased risk of percutaneous pEVAR failure. A total of 2381 accesses were collected in 1322 patients, 1249 (94.4%) male with a mean age of 73.5±8.3 years (range 45-97). The overall technical success rate was 96.8% (2305/2381). Major intraoperative access-related complications requiring conversion to surgical cut-down were observed in 3.2% of the cases (76/2381). One-month pEVAR failure-rate was 0.25% (6/2381). Presence of femoral artery calcifications resulted to be a significant predictor of technical failure (OR: 1.69; 95% CI: 1.03-2.77; P=0.036) at multivariate analysis. No significant association was observed with sex (P=0.28), obesity (P=0.64), CFA diameter (P=0.32), level of CFA bifurcation (P=0.94) and sheath size >18 F (P=0.24). The use of Proglide was associated with a lower failure rate compared to Prostar XL (2.5% vs. 3.3%) despite not statistically significant (P=0.33). The results of the IPER registry confirm the high technical success rate of percutaneous EVAR when performed by experienced operators, even in

  9. Outcomes of Endovascular Aneurysm Repair using the Ovation Stent Graft System in Adverse Anatomy.

    Science.gov (United States)

    Greaves, Nicholas S; Moore, Aiden; Seriki, Dare; Ghosh, Jonathan

    2018-04-01

    The aim was the evaluation of mid-term efficacy and safety outcome measures for the Ovation (Endologix, Santa Rosa, CA, USA) stent graft system in the management of infrarenal abdominal aortic aneurysms (iAAA) with adverse anatomy. A retrospective observational study of all patients undergoing elective iAAA repair was carried out from 2012 to 2017 using Ovation Prime or iX stent grafts with a minimum of 3 months follow-up at a single UK vascular centre. Post-operative surveillance involved computed tomography scans at 3 months and 1 year, with duplex ultrasound yearly thereafter. Outcome measures were established with retrospective analysis of pre- and post-operative imaging, and included peri-operative mortality, major adverse events, limb complications, aneurysm diameter change, and endoleak rates. All patients were within Ovation instructions for use (IFU), and assessment was made to determine whether aneurysms had anatomical features considered adverse for other commonly used stent graft platforms. Ovation stent grafts were implanted in 52 patients (79% male, mean age 75.7 years) with a mean aneurysm diameter of 62.5 mm (range 55-107 mm). There was 100% technical deployment success. The 30 day mortality was 0% and there was no aneurysm related mortality during follow-up (median 24 months, range 3-48 months). There were no type I or III endoleaks, but 19% developed type II endoleaks with one patient requiring re-intervention. No iliac limb occlusions were identified but one case required relining for limb kinking. All 52 cases were within the IFU for Ovation but only 12% met the IFU criteria for the Cook and Medtronic devices. The mid-term experience with Ovation demonstrates safe, durable treatment of iAAAs, including those with unfavourable anatomy, frequently off IFU for other commonly used devices. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  10. Aortic root replacement after previous surgical intervention on the aortic valve, aortic root, or ascending aorta.

    Science.gov (United States)

    Kirsch, E W Matthias; Radu, N Costin; Mekontso-Dessap, Armand; Hillion, Marie-Line; Loisance, Daniel

    2006-03-01

    Aortic root replacement after a previous operation on the aortic valve, aortic root, or ascending aorta remains a major challenge. Records of 56 consecutive patients (44 men; mean age, 56.4 +/- 13.6 years) undergoing reoperative aortic root replacement between June 1994 and June 2005 were reviewed retrospectively. Reoperation was performed 9.4 +/- 6.7 years after the last cardiac operation. Indications for reoperation were true aneurysm (n = 14 [25%]), false aneurysm (n = 10 [18%]), dissection or redissection (n = 9 [16%]), structural or nonstructural valve dysfunction (n = 10 [18%]), prosthetic valve-graft infection (n = 12 [21%]), and miscellaneous (n = 1 [2%]). Procedures performed were aortic root replacement (n = 47 [84%]), aortic root replacement plus mitral valve procedure (n = 5 [9%]), and aortic root replacement plus arch replacement (n = 4 [7%]). In 14 (25%) patients coronary artery bypass grafting had to be performed unexpectedly during the same procedure or immediately after the procedure to re-establish coronary perfusion. Hospital mortality reached 17.9% (n = 10). Multivariate logistic regression analysis revealed the need for unplanned perioperative coronary artery bypass grafting as the sole independent risk factor for hospital death (P = .005). Actuarial survival was 83.8% +/- 4.9% at 1 month, 73.0% +/- 6.3% at 1 year, and 65.7% +/- 9.0% at 5 years after the operation. One patient had recurrence of endocarditis 6.7 months after the operation and required repeated homograft aortic root replacement. Reoperative aortic root replacement remains associated with a high postoperative mortality. The need to perform unplanned coronary artery bypass grafting during reoperative aortic root replacement is a major risk factor for hospital death. The optimal technique for coronary reconstruction in this setting remains to be debated.

  11. Endovascular Aneurysm Repair of Acute Occlusion of Abdominal Aortic Aneurysm with Intra-Aneurysmal Dissection.

    Science.gov (United States)

    Terai, Yasuhiko; Mitsuoka, Hiroshi; Nakai, Masanao; Goto, Shinnosuke; Miyano, Yuta; Tsuchiya, Hirokazu; Yamazaki, Fumio

    2015-11-01

    To report a rare case of acute abdominal aortic aneurysm (AAA) occlusion successfully treated by endovascular aneurysm repair (EVAR). An 89-year-old man complained of severe back pain and weakness in the bilateral lower extremities. Although there were neither acute ischemic signs on the brain computed tomography (CT) nor critical leg ischemia, the patient presented progressing weakness in the bilateral lower extremities and decreased sensation in the perianal and saddle area. Contrast-enhanced CT demonstrated an infrarenal AAA, the formation of an ulcer-like lesion in the aneurysmal wall, and the complete occlusion of distal AAA because of the caudal extension of intramural hematoma. Both common iliac arteries were patent because of the development of collateral vessels. The neurologic symptoms were considered to be caused by the occlusion of lumbar radicular arteries. EVAR seemed anatomically feasible, if the occlusion could be crossed by guidewires from both side of the common femoral artery. Wires easily traversed the occlusion, and the stent graft could be smoothly unwrapped and opened. The patient could recover decent iliac arterial flow. The neurovascular deficits recovered within 4 days after the procedure. Although our experience may not be reproduced in all case of AAA occlusion, EVAR warrants consideration to reduce the high mortality rate associated with the classical treatments. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. [Occlusive aortic disease as coral reef aorta--experience in 80 cases].

    Science.gov (United States)

    Sagban, A T; Grotemeyer, D; Rehbein, H; Sandmann, W; Duran, M; Balzer, K M; Grabitz, K

    2010-10-01

    Coral reef aorta (CRA) is described as rock-hard calcifications in the visceral part of the aorta. These heavily calcified plaques grow into the lumen and can cause significant stenoses, leading to malperfusion of the lower limbs, visceral ischaemia or hypertension due to renal ischaemia. From 1/1984 to 11/2008, 80 patients (26 m, 54 f, mean age 61.6, range 14 to 86 years) underwent treatment in the Department of Vascular Surgery and Kidney Transplantation, Heinrich-Heine-University Hospital for CRA. The present study is based on a review of patient records and prospective follow-up in our outpatient clinic. The most frequent finding was renovascular hypertension (n=33, 41.3%) causing headache, vertigo and visual symptoms. Intermittent claudication due to peripheral arterial occlusive disease was found in 35 cases (43.8%). 15 patients (18.8%) presented with chronic visceral ischaemia causing diarrhoea, weight loss and abdominal pain. 79 patients (98.7%) underwent surgery; in 73 (93.7%) aortic reconstruction was achieved with thromboendarterectomy, on an isolated suprarenal segment in 7 (9.3%), an infrarenal segment in 21 (26.6%), and the supra- and infrarenal aorta in 45 cases (60%). Desobliteration of renal arteries was performed in 47 (one-sided n=8, 10.1%; both arteries n=39, 49.4%); the aortic bifurcation was desobliterated in 37 (46.8%), extension into iliac arteries was necessary in 29 cases (one-sided n=4, 5.1%; both arteries n=25, 31.6%). The coeliac trunk was desobliterated in 43% (n=34), the superior mesenteric artery in 44.3% (n=35) and the inferior mesenteric artery in 20.3% (n=16). In 15 cases additional revascularisation (bypass, transposition, graft interposition) was necessary. Surgical access was via a left-sided thoracoabdominal incision in 56.4% (n=45) and via laparotomy in 41.8% (n=33). The 30-day lethality was 8.7% (n=7). Postoperative complications requiring corrective surgery occurred in 11 patients (13.9%). Almost ⅓ of the patients (n=19

  13. Percutaneous Transabdominal Approach for the Treatment of Endoleaks after Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young; Lee, Do Yun; Lee, Kwang Hun [Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Won, Jong Yun [Gangnam Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Choi, Dong Hoon; Shim, Won Heum [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-02-15

    The purpose of this study was to evaluate the technical feasibility and clinical efficacy of percutaneous transabdominal treatment of endoleaks after endovascular aneurysm repair. Between 2000 and 2007, six patients with type I (n = 4) or II (n = 2) endoleaks were treated by the percutaneous transabdominal approach using embolization with N-butyl cyanoacrylate with or without coils. Five patients underwent a single session and one patient had two sessions of embolization. The median time between aneurysm repair and endoleak treatment was 25.5 months (range: 0-84 months). Follow-up CT images were evaluated for changes in the size and shape of the aneurysm sac and presence or resolution of endoleaks. The median follow-up after endoleak treatment was 16.4 months (range: 0-37 months). Technical success was achieved in all six patients. Clinical success was achieved in four patients with complete resolution of the endoleak confirmed by follow-up CT. Clinical failure was observed in two patients. One eventually underwent surgical conversion, and the other was lost to follow-up. There were no procedure-related complications. The percutaneous transabdominal approach for the treatment of type I or II endoleaks, after endovascular aneurysm repair, is an alternative method when conventional endovascular methods have failed.

  14. Arterial homograft and medical therapy in pseudoaneurysm of infrarenal aorta concomitant with recurrent right ventricular thrombus in Behcet's disease

    International Nuclear Information System (INIS)

    Vahedian, Jalal; Sadeghapour, Ali

    2006-01-01

    Pseudoaneurysm of the infrarenal aorta due to Behcet s disease is very rare. We report a case of pseudoaneurysm associated with Behcet s disease in a 17-year-old boy with a recurrent right ventricular thrombus successfully treated with revascularization using arterial homograft patch. Echocardiography examination revealed a right ventricular mass, thought to be a thrombus in an unusual location. Postoperatively, the findings of the pathologic examination confirmed the mass as a thrombus. When the patient was subsequently re-admitted to the emergency unit with complaints of severe abdominal pain, fever, fatigue, sinus tachycardia, and a pulsating and tender abdominal mass, a right ventricular thrombus and a large pseudoaneurysm of the abdominal aorta were found on echocardiography and angiography. The patient underwent resection of the aortic aneurysm and aortoplasty, using arterial homograft patch, and received immunosuppressive and anticoagulation therapy. The thrombus of the right ventricle disappeared 4 months later. This case indicates that a right ventricular thrombosis in Behcet s disease may be managed by medical therapy. (author)

  15. Aortic insufficiency

    Science.gov (United States)

    ... page, please enable JavaScript. Aortic insufficiency is a heart valve disease in which the aortic valve does not close ... aortic insufficiency Images Aortic insufficiency References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ...

  16. Vascular graft infections with Mycoplasma

    DEFF Research Database (Denmark)

    Levi-Mazloum, Niels Donald; Skov Jensen, J; Prag, J

    1995-01-01

    laboratory techniques, the percentage of culture-negative yet grossly infected vascular grafts seems to be increasing and is not adequately explained by the prior use of antibiotics. We have recently reported the first case of aortic graft infection with Mycoplasma. We therefore suggest the hypothesis...... that the large number of culture-negative yet grossly infected vascular grafts may be due to Mycoplasma infection not detected with conventional laboratory technique....

  17. Congenital absence of infrarenal IVC and iliac venous system : Unusual collateral Pathways

    International Nuclear Information System (INIS)

    Lee, Jin Joo; Lee, Byung Hee; Kim, Kie Hwan; Do, Young Soo; Chin, Soo Yil

    1994-01-01

    We present a case with congenital absence of the infrarenal portion of inferior vena cava and iliac venous system, showing unusual venous collaterals including the left ovarian venous collateral via parametrial venous complex, and a mesenteric-periureteric venous connection. The venous collateral pathways were demonstrated by computed tomography and venography

  18. An unusual case of aortic rupture after deployment of a bare stent in the treatment of aortic dissection in a patient with giant-cell arteritis.

    Science.gov (United States)

    Rynio, Pawel; Kazimierczak, Arkadiusz; Gutowski, Piotr; Cnotliwy, Miloslaw

    2017-06-01

    Giant-cell arteritis is associated with a higher risk of aortic aneurysm and aortic dissection formation. We present a women with aortic dissection type B treated with a stent graft and bare-metal stent implantation. After the stent deployment we noticed aortic rupture, which was successfully treated with implantation of an additional stent graft. This report highlights the difficulty of endovascular therapy in patients with giant-cell arteritis. We have to bear in mind that chronic inflammation of the aorta leads to a more fragile aortic wall than normal. We recommend the use of a stent graft over a bare-metal stent and gentle use of a balloon catheter.

  19. The relevance of aortic endograft prosthetic infection

    NARCIS (Netherlands)

    Cernohorsky, Paul; Reijnen, Michel M. P. J.; Tielliu, Ignace F. J.; van Sterkenburg, Steven M. M.; van den Dungen, Jan J. A. M.; Zeebregts, Clark J.

    Background: Vascular prosthetic graft infection is a severe complication after open aortic aneurysm repair. Reports of infected endografts are scarce. General treatment consensus with infected graft material is that it should be removed completely. The objective of this study was to describe the

  20. Automatic segmentation of the wire frame of stent grafts from CT data.

    NARCIS (Netherlands)

    Klein, A.; Vliet, J.A. van der; Oostveen, L.J.; Hoogeveen, Y.L.; Schultze Kool, L.J.; Renema, W.K.J.; Slump, C.H.

    2012-01-01

    Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion

  1. Stent Graft in Managing Juxta-Renal Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Prabhudesai, V.; Mitra, K.; West, D. J.; Dean, M. R. E.

    2003-01-01

    Endovascular procedures are frequently used as an alternative to surgical bypass in aortic and iliac occlusion. Stents have revolutionized the scope of such endovascular procedures, but there are few reports of stents or stent grafts in occlusive juxta-renal aortic occlusion. We present a case where such occlusion was managed by use of a stent graft with successful outcome

  2. Preventative valve-sparing aortic root replacement and pregnancy outcome in Marfan syndrome.

    Science.gov (United States)

    Sokol, Vesna; Zlopasa, Gordan; Herman, Mislav; Planinić, Pavao; Micevska, Ana

    2012-06-01

    In Marfan syndrome, with dilatation of the aortic root secondary to an underlying connective tissue defect, pregnancy can cause hemodynamic stress leading to the development of an aortic aneurysm and even a fatal aortic dissection. In the presence of existing aortic root enlargement and a family history of aortic dissection, preventative elective surgery is suggested. Aortic root replacement with or without a valve-sparing procedure is superior to total aortic root replacement with prosthetic valve/tube graft. It provides excellent survival with low rates of aortic - valve related complications.

  3. Delayed Presentation of a Giant Ascending Aortic Aneurysm following Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Tugrul Göncü

    2009-01-01

    Full Text Available Giant ascending aortic aneurysm formation following aortic valve replacement is rare. A 28-year-old man who underwent aortic valve replacement with a prosthetic valve for aortic regurgitation secondary to congenital bicuspid aortic valve about 10 years ago was diagnosed with a giant ascending aortic aneurysm about 16 cm in diameter in follow-up. The aneurysm was resected leaving the functional old mechanical prosthesis in place and implanted a 34-mm Hemashield woven graft, associated with the left and right coronary artery button implantation. Histological findings of the aortic aneurysm wall showed cystic medial necrosis. The postoperative course was uneventful and postoperative examination demonstrated good surgical results.

  4. Midterm outcome of EndoAnchors for the prevention of endoleak and stent-graft migration in patients with challenging proximal aortic neck anatomy.

    Science.gov (United States)

    Jordan, William D; de Vries, Jean-Paul P M; Ouriel, Kenneth; Mehta, Manish; Varnagy, David; Moore, William M; Arko, Frank R; Joye, James; Henretta, John

    2015-04-01

    To explore the use of EndoAnchors as an adjunct to endovascular abdominal aortic aneurysm repair for prevention of proximal neck complications in patients with challenging neck anatomy. Over a 28-month period, 208 patients (159 men; mean age 72±8 years) were enrolled in the ANCHOR prospective, multicenter registry (ClinicalTrials.gov; identifier NCT01534819) for prophylaxis against proximal neck complications. Patients were eligible when, in the opinion of the investigators, they were at increased risk for type Ia endoleak or migration owing to a hostile neck (length 28 mm, angulation >60°, mural thrombus or calcium >2 mm in thickness or >180° in circumference, or conical shape). Overall, 123/157 (78.3%) patients met the criteria for a hostile neck according to core laboratory assessment of 157 adequate preoperative computed tomographic (CT) images. Implantation of EndoAnchors was technically successful in 204/208 (98.1%) patients. The frequency of fracture was 0.3% (3/1118); there were no clinical sequelae associated with the fractures. Over the mean 14-month follow-up, 95.2% of patients were alive, and no deaths were attributable to EndoAnchors. There were no ruptures, migrations, or open surgical conversions. Aneurysm-related reinterventions were performed in 8 (3.8%) patients. Among 130 patients with postprocedure contrast CT studies, core laboratory analysis identified 2 (1.5%) patients with type Ia endoleaks. Aneurysm sac diameter decreased >5 mm in 42.9% of patients with CT scans at or beyond 1 year; 1.6% of patients developed sac enlargement >5 mm. Prophylactic EndoAnchor use for challenging aortic neck anatomy was associated with satisfactory midterm results. © The Author(s) 2015.

  5. Quantification of abdominal aortic deformation after EVAR

    Science.gov (United States)

    Demirci, Stefanie; Manstad-Hulaas, Frode; Navab, Nassir

    2009-02-01

    Quantification of abdominal aortic deformation is an important requirement for the evaluation of endovascular stenting procedures and the further refinement of stent graft design. During endovascular aortic repair (EVAR) treatment, the aortic shape is subject to severe deformation that is imposed by medical instruments such as guide wires, catheters, and, the stent graft. This deformation can affect the flow characteristics and morphology of the aorta which have been shown to be elicitors for stent graft failures and be reason for reappearance of aneurysms. We present a method for quantifying the deformation of an aneurysmatic aorta imposed by an inserted stent graft device. The outline of the procedure includes initial rigid alignment of the two abdominal scans, segmentation of abdominal vessel trees, and automatic reduction of their centerline structures to one specified region of interest around the aorta. This is accomplished by preprocessing and remodeling of the pre- and postoperative aortic shapes before performing a non-rigid registration. We further narrow the resulting displacement fields to only include local non-rigid deformation and therefore, eliminate all remaining global rigid transformations. Finally, deformations for specified locations can be calculated from the resulting displacement fields. In order to evaluate our method, experiments for the extraction of aortic deformation fields are conducted on 15 patient datasets from endovascular aortic repair (EVAR) treatment. A visual assessment of the registration results and evaluation of the usage of deformation quantification were performed by two vascular surgeons and one interventional radiologist who are all experts in EVAR procedures.

  6. Skin graft

    Science.gov (United States)

    Skin transplant; Skin autografting; FTSG; STSG; Split thickness skin graft; Full thickness skin graft ... donor site. Most people who are having a skin graft have a split-thickness skin graft. This takes ...

  7. Rupture of an Abdominal Aortic Aneurysm in a Young Man with Marfan Syndrome.

    Science.gov (United States)

    Pedersen, Maria Weinkouff; Huynh, Khiem Dinh; Baandrup, Ulrik Thorngren; Nielsen, Dorte Guldbrand; Andersen, Niels Holmark

    2018-04-01

    Abdominal aortic aneurysms (AAAs) are very rare in Marfan syndrome. We present a case with a young nonsmoking and normotensive male with Marfan syndrome, who developed an infrarenal AAA that presented with rupture to the retroperitoneal cavity causing life-threatening bleeding shock. The patient had acute aortic surgery and survived. Five months before this incident, the patient had uneventful elective aortic root replacement (ad modum David) due to an enlarged aortic root. At that time, his abdominal aorta was assessed with a routine ultrasound scan that showed a normal-sized abdominal aorta. This documents that the aneurysm had evolved very rapidly despite young age and absence of risk factors. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Reverse extra-anatomic aortic arch debranching procedure allowing thoracic endovascular aortic repair of a chronic ascending aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ludovic Canaud, MD, PhD

    2018-06-01

    Full Text Available A 79-year-old woman was admitted with a large chronic dissecting ascending aortic aneurysm starting 5 mm distal to the ostia of the left coronary artery and ending immediately proximal to the innominate artery. A reverse extra-anatomic aortic arch debranching procedure was performed. During the same operative time, through a transapical approach, a thoracic stent graft was deployed with the proximal landing zone just distal to the coronary ostia and the distal landing zone excluding the origin of the left common carotid artery. The postoperative course was uneventful. Computed tomography at 12 months documented patent extra-anatomic aortic arch debranching and no evidence of endoleak. Keywords: Ascending aorta, Thoracic aorta, Aortic dissection, Stent graft

  9. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  10. Management strategies for thoracic stent-graft repair of distal aortic arch lesions: is intentional subclavian artery occlusion a safe procedure?

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio; Salvatori, Filippo Maria; Pucci, Armando; Lucatelli, Pierleone; Rossi, Plinio; Passariello, Roberto [University of Rome La Sapienza, Department of Radiological Sciences, Rome (Italy); Dake, Michael D. [Stanford University School of Medicine, Department of Cardiothoracic Surgery Radiology, Stanford, CA (United States); Mazzesi, Giuseppe [University of Rome La Sapienza, Institute of Heart and Great Vessels, Rome (Italy)

    2009-10-15

    The aim of this retrospective analysis was to assess the clinical consequences after intentional left subclavian artery (LSA) occlusion. Thirty-seven patients, 27 type B dissection and 10 thoracic aneurysm, with short proximal neck (less than 2 cm) underwent endovascular treatment with intentional exclusion of LSA origin. No immediate complications occurred. Mean arterial pressure gradient, between right and left arms, ranged from 15 to 45 mmHg. After a mean follow-up of 43.70{+-}24.01 months, mild left arm symptoms secondary to flow reduction occurred in eight cases (21.6%) but only one required LSA transposition, after 8 months, for visual impairment. Type II endoleaks from excluded LSA occurred in 10 cases (27.0%): in seven patients, leaks were treated with coils and/or glue embolization; in one case, leak sealed spontaneously; one patient died before leak embolization could occur; one patient refused any further treatment. Intentional exclusion of the LSA may be justified when a longer proximal landing zone in the aortic arch is required. (orig.)

  11. Endoluminal treatment of aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Chavan, Ajay; Lotz, Joachim; Galanski, Michael [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Strasse 1, 30625, Hannover (Germany); Oelert, Frank; Haverich, Axel; Karck, Matthias [Department of Thoracic and Cardiovascular Surgery, Hannover Medical School, Carl Neuberg Strasse 1, 30625, Hannover (Germany)

    2003-11-01

    Aortic dissection is most often a catastrophic medical emergency which, if untreated, can be potentially fatal. The intention of therapy in patients with aortic dissection is to prevent aortic rupture or aneurysm formation as well as to relieve branch vessel ischaemia. Patients with aortic dissection are often poor candidates for anaesthesia and surgery and the surgical procedure itself is challenging requiring thoracotomy, aortic cross clamping, blood transfusion as well as prolonged hospital stay in some cases. Operative mortality is especially high in patients with critical mesenteric or renal ischaemia. The past decade has experienced the emergence of a number of interventional radiological or minimally invasive techniques which have significantly improved the management of patients with aortic dissection. These include stent grafting for entry site closure to prevent aneurysmatic widening of the false lumen as well as percutaneous techniques such as balloon fenestration of the intimal flap and aortic true lumen stenting to alleviate branch vessel ischaemia. False lumen thrombosis following entry closure with stent grafts has been observed in 86-100% of patients, whereas percutaneous interventions are able to effectively relieve organ ischaemia in approximately 90% of the cases. In the years to come, it is to be expected that these endoluminal techniques will become the method of choice for treating most type-B dissections and will assist in significantly reducing the number of open surgical procedures required for type-A dissections. The intention of this article is to provide an overview of the current status of these endoluminal techniques based on our own experience as well as on a review of the relevant literature. (orig.)

  12. Endoluminal treatment of aortic dissection

    International Nuclear Information System (INIS)

    Chavan, Ajay; Lotz, Joachim; Galanski, Michael; Oelert, Frank; Haverich, Axel; Karck, Matthias

    2003-01-01

    Aortic dissection is most often a catastrophic medical emergency which, if untreated, can be potentially fatal. The intention of therapy in patients with aortic dissection is to prevent aortic rupture or aneurysm formation as well as to relieve branch vessel ischaemia. Patients with aortic dissection are often poor candidates for anaesthesia and surgery and the surgical procedure itself is challenging requiring thoracotomy, aortic cross clamping, blood transfusion as well as prolonged hospital stay in some cases. Operative mortality is especially high in patients with critical mesenteric or renal ischaemia. The past decade has experienced the emergence of a number of interventional radiological or minimally invasive techniques which have significantly improved the management of patients with aortic dissection. These include stent grafting for entry site closure to prevent aneurysmatic widening of the false lumen as well as percutaneous techniques such as balloon fenestration of the intimal flap and aortic true lumen stenting to alleviate branch vessel ischaemia. False lumen thrombosis following entry closure with stent grafts has been observed in 86-100% of patients, whereas percutaneous interventions are able to effectively relieve organ ischaemia in approximately 90% of the cases. In the years to come, it is to be expected that these endoluminal techniques will become the method of choice for treating most type-B dissections and will assist in significantly reducing the number of open surgical procedures required for type-A dissections. The intention of this article is to provide an overview of the current status of these endoluminal techniques based on our own experience as well as on a review of the relevant literature. (orig.)

  13. Reoperative Aortic Root Replacement in Patients with Previous Aortic Root or Aortic Valve Procedures

    Directory of Open Access Journals (Sweden)

    Byung Kwon Chong

    2016-08-01

    Full Text Available Background: Generalization of standardized surgical techniques to treat aortic valve (AV and aortic root diseases has benefited large numbers of patients. As a consequence of the proliferation of patients receiving aortic root surgeries, surgeons are more frequently challenged by reoperative aortic root procedures. The aim of this study was to evaluate the outcomes of redo-aortic root replacement (ARR. Methods: We retrospectively reviewed 66 patients (36 male; mean age, 44.5±9.5 years who underwent redo-ARR following AV or aortic root procedures between April 1995 and June 2015. Results: Emergency surgeries comprised 43.9% (n=29. Indications for the redo-ARR were aneurysm (n=12, pseudoaneurysm (n=1, or dissection (n=6 of the residual native aortic sinus in 19 patients (28.8%, native AV dysfunction in 8 patients (12.1%, structural dysfunction of an implanted bioprosthetic AV in 19 patients (28.8%, and infection of previously replaced AV or proximal aortic grafts in 30 patients (45.5%. There were 3 early deaths (4.5%. During follow- up (median, 54.65 months; quartile 1–3, 17.93 to 95.71 months, there were 14 late deaths (21.2%, and 9 valve-related complications including reoperation of the aortic root in 1 patient, infective endocarditis in 3 patients, and hemorrhagic events in 5 patients. Overall survival and event-free survival rates at 5 years were 81.5%±5.1% and 76.4%±5.4%, respectively. Conclusion: Despite technical challenges and a high rate of emergency conditions in patients requiring redo-ARR, early and late outcomes were acceptable in these patients.

  14. Pre- and Postoperative Imaging of the Aortic Root

    Science.gov (United States)

    Chan, Frandics P.; Mitchell, R. Scott; Miller, D. Craig; Fleischmann, Dominik

    2016-01-01

    Three-dimensional datasets acquired using computed tomography and magnetic resonance imaging are ideally suited for characterization of the aortic root. These modalities offer different advantages and limitations, which must be weighed according to the clinical context. This article provides an overview of current aortic root imaging, highlighting normal anatomy, pathologic conditions, imaging techniques, measurement thresholds, relevant surgical procedures, postoperative complications and potential imaging pitfalls. Patients with a range of clinical conditions are predisposed to aortic root disease, including Marfan syndrome, bicuspid aortic valve, vascular Ehlers-Danlos syndrome, and Loeys-Dietz syndrome. Various surgical techniques may be used to repair the aortic root, including placement of a composite valve graft, such as the Bentall and Cabrol procedures; placement of an aortic root graft with preservation of the native valve, such as the Yacoub and David techniques; and implantation of a biologic graft, such as a homograft, autograft, or xenograft. Potential imaging pitfalls in the postoperative period include mimickers of pathologic processes such as felt pledgets, graft folds, and nonabsorbable hemostatic agents. Postoperative complications that may be encountered include pseudoaneurysms, infection, and dehiscence. Radiologists should be familiar with normal aortic root anatomy, surgical procedures, and postoperative complications, to accurately interpret pre- and postoperative imaging performed for evaluation of the aortic root. Online supplemental material is available for this article. ©RSNA, 2015 PMID:26761529

  15. Tratamento das afecções da aorta com a primeira geração de stents auto-expansíveis Aortic diseases treatment with a first generation of self expanding stent-grafts

    Directory of Open Access Journals (Sweden)

    Wagner Michael PEREIRA

    2001-09-01

    ,57%, com 70,15% dos pacientes livre de eventos em 33 meses de seguimento, tornando o método factível e diminuindo a mortalidade no tratamento cirúrgico das dissecções agudas e crônicas do tipo B.INTRODUCTION: The authors describe the implantation of an endovascular self-expanding stents grafts at 33 months of follow-up. The use can be a new alternative for the treatment of descending aortic dissections and aneurysms disease. MATERIAL AND METHODS: From April 1998 to November 2000 (32 months, 37 endovascular stent grafts were implanted, 21 in acute dissections type B, 7 in acute dissections type A and 9 in chronic dissections type B and aneurysms ones. The age varied between 39 and 79 years (mean=57.94 ± 1.91 years, considering that 64.86% were male patients. The patients were submitted to median esternotomy, extracorporeal circulation (ECC, with deep hipothermia (18-20ºC, total circulatory arrest (TCA, and retrograde cerebral perfusion (RCP. The transverse aorta was incised and the stent was implanted in the descending proximal aorta with the aid sometimes of aortoscopy. The times of ECC, aortic clamping, TCA, RCP, rewarming, mechanic ventilation, hospitalization, trans and post-operative bleeding, blood replacement, events curve and survival curve were analyzed. RESULTS: The hospital mortality (30 days was 13.51%; 32 have been followed up from 1 to 33 months, 70.7% are free of events and survival curve with 63.19% (33 months. CONCLUSIONS: The implant of self-expanding intraluminal stent grafts presented has lower hospital mortality in the acute phase and follow-up in acute aortic dissections type B (10% than clinical treatment (IRAD. In spite of the small sample the procedure is promising and needs longer follow-up.

  16. Risk stratification by pre-operative cardiopulmonary exercise testing improves outcomes following elective abdominal aortic aneurysm surgery: a cohort study.

    Science.gov (United States)

    Goodyear, Stephen J; Yow, Heng; Saedon, Mahmud; Shakespeare, Joanna; Hill, Christopher E; Watson, Duncan; Marshall, Colette; Mahmood, Asif; Higman, Daniel; Imray, Christopher He

    2013-05-19

    In 2009, the NHS evidence adoption center and National Institute for Health and Care Excellence (NICE) published a review of the use of endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs). They recommended the development of a risk-assessment tool to help identify AAA patients with greater or lesser risk of operative mortality and to contribute to mortality prediction.A low anaerobic threshold (AT), which is a reliable, objective measure of pre-operative cardiorespiratory fitness, as determined by pre-operative cardiopulmonary exercise testing (CPET) is associated with poor surgical outcomes for major abdominal surgery. We aimed to assess the impact of a CPET-based risk-stratification strategy upon perioperative mortality, length of stay and non-operative costs for elective (open and endovascular) infra-renal AAA patients. A retrospective cohort study was undertaken. Pre-operative CPET-based selection for elective surgical intervention was introduced in 2007. An anonymized cohort of 230 consecutive infra-renal AAA patients (2007 to 2011) was studied. A historical control group of 128 consecutive infra-renal AAA patients (2003 to 2007) was identified for comparison.Comparative analysis of demographic and outcome data for CPET-pass (AT ≥ 11 ml/kg/min), CPET-fail (AT 11 ml/kg/min was associated with reduced perioperative mortality (open cases only), LOS, survival and inpatient costs (open and endovascular repair) for elective infra-renal AAA surgery.

  17. THE IMPACT OF DIAGNOSTIC DISCREPANCIES IN AORTIC DISSECTION MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Abdalla Hassan

    2016-01-01

    Full Text Available Aortic dissection is uncommon with high mortality rate if untreated. We report a challenging case of long segment aortic dissection in which the dissection type was very difficult to identify due to limitations of the available imaging studies. 66-year-old male presented to us with 3 days history of chest pain and difficulty breathing. He is known to be hypertensive. In the emergency room, patient has systolic blood pressure >190. Chest X-ray showed widening of mediastinum. CT angiography of chest and abdomen showed an acute dissection of the thoracic aorta extending from the mid ascending aorta to the infra-renal aorta suggestive of Stanford type A aortic dissection. Transthoracic and Trans-esophageal echocardiography revealed a partially calcified intimal flap in the distal portion of the arch and in the descending thoracic aorta suggestive of Stanford type B aortic dissection. Medical treatment started, and repeated CT angiography was obtained and it confirmed type B aortic dissection. One week after discharge, patient was readmitted with severe neck pain and difficulty breathing. CT chest without contrast showed grossly stable appearance of type A dissection consistent with the first CT angiography. Cardiothoracic surgery immediately reevaluated the situation and recommended surgical intervention.

  18. Aortic stenosis

    Science.gov (United States)

    ... Images Aortic stenosis Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ... ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/ ...

  19. Unusual rapid evolution of type B aortic dissection in a marfan patient following heart transplantation: successful endovascular treatment.

    Science.gov (United States)

    Botta, L; Russo, V; Grigioni, F; Arpesella, G; Rocchi, G; Di Bartolomeo, R; Fattori, R

    2006-10-01

    A patient with Marfan syndrome with previous Bentall operation for mitral and tricuspid valve repair, required orthotopic cardiac transplantation for end stage cardiomyopathy. Postoperatively he suffered type-B aortic dissection, despite normal aortic diameters. Following sudden increase of aortic diameters, two years later, he underwent successful stent graft implantation. In patients with Marfan syndrome, post transplantation morbidity is high, with a 40% incidence of thoracic aortic dissection. This case highlights the potential of endovascular approach for treating post-transplantation aortic dissection.

  20. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  1. Outcome of Pregnancies After Balloon Occlusion of the Infrarenal Abdominal Aorta During Caesarean in 230 Patients With Placenta Praevia Accreta

    International Nuclear Information System (INIS)

    Wu, Qinghua; Liu, Zhuan; Zhao, Xianlan; Liu, Cai; Wang, Yanli; Chu, Qinjun; Wang, Xiaojuan; Chen, Zhimin

    2016-01-01

    PurposeTo explore the efficacy and safety of prophylactic temporary balloon occlusion of the infrarenal abdominal aorta during caesarean for the management of patients with placenta praevia accreta.MethodsTwo hundred and sixty-eight cases of placenta praevia accreta from January 2012 to June 2015 were retrospectively reviewed. Group A included two hundred and thirty patients who underwent prophylactic temporary balloon occlusion of infrarenal abdominal aorta followed by caesarean section. Group B included thirty-eight patients who underwent caesarean without endovascular intervention. The parameters including operating room time, estimated blood loss, blood transfusion volume, PT (prothrombin time) during operation, days in the intensive care unit, and total hospital days were compared between the two groups.ResultsThe operating room time, estimated blood loss, PT, the incidence of hysterectomy, blood transfusion volume, postpartum haemorrhage, and days in intensive care unit were lower in group A than in group B, with statistical significance (P   0.05). No patient in the group with prophylactic temporary balloon occlusion of the infrarenal abdominal aorta was performed hysterectomy, while three patients in group B were performed hysterectomy because of uncontrollable haemorrhage.ConclusionsThe results indicate that prophylactic temporary balloon occlusion of infrarenal abdominal aorta followed by caesarean section is safe and effective to control intraoperative blood loss and greatly decreases the risk of hysterectomy in patients with placenta praevia accreta.

  2. Expanding arch aneurysm causing a "kink" in a Bentall graft and heart failure.

    Science.gov (United States)

    Al-Mohaissen, Maha A; Skarsgard, Peter; Khoo, Clarence; Virani, Sean A; Munt, Brad; Leipsic, Jonathon; Ignaszewski, Andrew

    2012-07-01

    Marfan syndrome is associated with a high incidence of aortic root aneurysm and life-threatening aortic dissection. With the successful use of surgical aortic root replacement, dissection-related mortality has been significantly reduced. We present the case of a patient with Marfan syndrome who presented with heart failure secondary to an unusual graft-related complication 14 years after a Bentall procedure. Investigations revealed a supra-aortic stenosis resulting from a kink in the Bentall graft caused by pressure from an expanding aortic arch aneurysm. The patient underwent surgery with improvement in his ejection fraction and heart failure symptoms.

  3. Features of Debakey Ⅲ Aortic Dissection After Endovascular Graft Exclusion:Evaluation with DSCT Angiography%DebakeyⅢ型主动脉夹层腔内隔绝术后移植物及血管特征的双源CT血管成像研究

    Institute of Scientific and Technical Information of China (English)

    邵恒; 杨志刚; 唐思诗; 陈静; 邓雯; 彭礼清

    2011-01-01

    采用双源CT评价DebakeyⅢ型主动脉夹层腔内隔绝术后移植物及血管变化的特点.对39例DebakeyⅢ型主动脉夹层腔内隔绝术后患者的双源CT血管成像图像进行分析.发现39例患者术后均无支架断裂及移位,术后内漏15例(Ⅰ型12例、Ⅱ型2例、不明原因1例),17例假腔大量血栓形成,1例支架段假腔完全吸收.术前15例肾灌注异常病例,术后肾灌注改善9例,并且越靠近原发破口封堵部位,其血管重塑情况越明显.因此,双源CT血管成像可准确评价DebakeyⅢ型主动脉夹层腔内隔绝术后移植物情况及血管的解剖病理特点.%The purpose of this study was to evaluate the prothesis and vascular features of Debakey Ⅲ aortic dissection by DSCT angiography after endovascular graft exclusion. We performed a retrospective analysis of 39 Debakey Ⅲ aortic dissection patients who underwent DSCT angiography after endovascular graft exclusion. After the operations in this study, all the 39 patients had no stent fracture and migration, 15 among all the 39 had endoleaks (type Ⅰ 12 patients, typeⅡ 2 patients, 1 patient had no reason), 17 had large amount of thrombosis in false lumen, and 1 had false lumen outside the stent absorbed completely. While before the operations, 15 patients had abnormal renal perfusion pre-operation, and 9 of them had recovered after the operations. And the nearer located to the initial exclusive place, the more obviously the aortic remodeling occurred. In conclusion, DSCT angiography can accurately evaluate the prosthesis and anatomic-pathologic features of Debakey Ⅲ aortic dissection after endovascular graft exclusion.

  4. Experience with early postoperative feeding after abdominal aortic surgery.

    Science.gov (United States)

    Ko, Po-Jen; Hsieh, Hung-Chang; Liu, Yun-Hen; Liu, Hui-Ping

    2004-03-01

    Abdominal aortic surgery is a form of major vascular surgery, which traditionally involves long hospital stays and significant postoperative morbidity. Experiences with transit ileus are often encountered after the aortic surgery. Thus traditional postoperative care involves delayed oral feeding until the patients regain their normal bowel activities. This report examines the feasibility of early postoperative feeding after abdominal aortic aneurysm (AAA) open-repair. From May 2002 through May 2003, 10 consecutive patients with infrarenal AAA who underwent elective surgical open-repair by the same surgeon in our department were reviewed. All of them had been operated upon and cared for according to the early feeding postoperative care protocol, which comprised of adjuvant epidural anesthesia, postoperative patient controlled analgesia, early postoperative feeding and early rehabilitation. The postoperative recovery and length of hospital stay were reviewed and analyzed. All patients were able to sip water within 1 day postoperatively without trouble (Average; 12.4 hours postoperatively). All but one patient was put on regular diet within 3 days postoperatively (Average; 2.2 days postoperatively). The average postoperative length of stay in hospital was 5.8 days. No patient died or had major morbidity. Early postoperative feeding after open repair of abdominal aorta is safe and feasible. The postoperative recovery could be improved and the length of stay reduced by simply using adjuvant epidural anesthesia during surgery, postoperative epidural patient-controlled analgesia, early feeding, early ambulation, and early rehabilitation. The initial success of our postoperative recovery program of aortic repair was demonstrated.

  5. Postoperative CT findings of aortic aneurysm and dissection

    International Nuclear Information System (INIS)

    Seong, Su Ok; Lee, Ghi Jai; Kim, Mi Young; Moon, Hi Eun; Shim, Jae Chan; Lee, Hong Sup; Kim, Ho Kyun; Han, Chang Yul

    1995-01-01

    To assess the postoperative CT findings of aortic aneurysms or dissections treared by resection-and graft replacement or continuous-suture graft-inclusion technique. We reviewed postoperative follow-up CT findings of 14 patients, 19 cases. There were 8 patients (10 cases) of aortic aneurysm and 6 patients (9 cases) of aortic dissection which involved the thoracic aorta in 9 patients (13 cases) and abdominal aorta in 5 patients (6 cases). The interval of follow-up after operation was from 9 days to 2 year 9 months. On CT scans, we analyzed the appearance of graft materials, differences of CT findings between two surgical techniques, and normal or abnormal postoperative CT findings. Most of grafts appeared as hyperdense ring on precontrast scan, and all of them were not separated from aortic lumen on postcontrast scan. On CT findings of patients who were operated by continuous-suture graft-inclusion technique, perigraft thrombus was concentrically located with sharp demarcation by native aortic wall and its density was homogeneous, but in cases of those operated by resection-and graft replacement, perigraft hematoma was eccentrically located with indistinct margin and its density was heterogeneous and native aortic wall could not be delineated. In patients without complication, perigraft thrombus or hematoma (15 cases), perigraft calcification (11 cases), residual intimal flap (6 cases), graft deformity (4 cases), perigraft air (2 cases) and reconstructed vessels (1 cases) were noted. And in one patient with complication, perigraft flow was noted with more increased perigraft hematoma. Precise knowledge of the differences of CT findings between two surgical techniques and normal postoperative CT findings is crucial to evaluated the postoperative CT findings in aortic aneurysm and dissection

  6. Aorto-aortic intrathoracic bypass in surgical treatment of aortic

    International Nuclear Information System (INIS)

    Gutierrez Perez, F.; Duran Reyes, A.; Bigalli, D.; Filgueira Berobide, J.

    1998-01-01

    The prevalence of coarctation of the aorta is 6.5 percent of all congenital heart defects, according to national and international data. There is a restenosis rate of patients after surgery. Factors that influence this evolution depends on the age at which patients underwent surgery for the first time the anatomy of the aortic arch and type of surgical technique. Several procedures can be used to correct the coarctation, which include surgery and balloon catheter dilation. We present here a case of a patient of 22 years old, with a recurrent coarctation of the aorta studied by echocardiography and magnetic resonance imaging. The patient underwent surgery a third time. We used an anterior approach (median sternotomy) and performed an aortic bypass graft, intrathoracic, under cardiopulmonary bypass. Evolved favorably and was discharged on the sixth day of post operative day (Author) [es

  7. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  8. Enxerto venoso intercoronariano na revascularização de artéria coronária comprometida por dissecção de aorta tipo I Intercoronary venous graft in revascularization of the coronary artery involved by aortic dissection type I

    Directory of Open Access Journals (Sweden)

    Carlos Alberto C Abreu Filho

    1995-03-01

    Full Text Available Paciente de 39 anos, portador de hipertensão arterial não controlada, submetido a cirurgia para tratamento de dissecção aguda de aorta tipo I. Devido ao grande envolvimento do óstio coronário direito pela dissecção aórtica, optou-se pela ressecção da porção comprometida do vaso, com interposição de tubo não valvulado de Dacron na aorta ascendente, suspensão da valva aórtica e ligadura do óstio da artéria coronária direita. Como não havia presença de aterosclerose no ramo interventricular anterior e na artéria coronária direita, decidimos realizar um enxerto venoso entre as artérias. O enxerto intercoronário apresentou bom funcionamento e todo o território dependente da coronária direita manteve boa contratilidade. O paciente recebeu alta hospitalar em boas condições clínicas, com função rniocárdica preservada.A thirty nine-year-old patient presenting arterial hypertension was operated upon for type I acute aortic dissection. Due to important alterations in the ascendent aorta with involvement of the right coronary ostium, the surgical procedure included resection of the segment of aorta containing the intimal tear and replacement with a Dacron prosthesis, suspension of the aortic valve and ligadure of the right coronary ostium. Technical difficulties brought the necessity of a different approach for the myocardium revascularization. Instead of the traditional described procedures, an intercoronary venous graft was put between the anterior interventricular artery (branch of the left coronary artery and the right coronary artery. The intercoronary graft presented a good flow since the begining, keeping a good myocardial contratility. Patient left the hospital in a good clinical condition, with preserved myocardial function. Intercoronary graft should be an efficient alternative for revascularization of a corohary artery involved by aortic dissections.

  9. Hemolytic anemia caused by kinking of dacron grafts implanted in ...

    African Journals Online (AJOL)

    Background: Hemolytic anemia caused by a kinked Dacron graft is a rare complication after repair of acute aortic dissection. We present a case of hemolytic anemia due to kinking of previously implanted Dacron graft for ascending aorta dissection treated by surgery and replaced with new Dacron. Case Details: We report a ...

  10. Anteroposterior diameter of the infrarenal abdominal aorta is higher in women with polycystic ovary syndrome

    Directory of Open Access Journals (Sweden)

    Marco Matteo Ciccone

    2009-06-01

    Full Text Available Marco Matteo Ciccone1, Stefano Favale1, Anish Bhuva4, Pietro Scicchitano1, Vito Caragnano1, Cristina Lavopa2, Giovanni De Pergola3, Giuseppe Loverro21Department of Cardiology; 2Department of Gynecology and Obstetrics; 3Section of Internal Medicine, Endocrinology, Andrology, and Metabolic Diseases, University of Bari, DETO, Italy; 4University College of London, London, UKBackground: Women affected by polycystic ovary syndrome (PCOS are known to be at higher risk of cardiovascular disease. The aim of this study was to identify the artery that first is affected by early pre-atherosclerotic changes in PCOS. Methods: Twenty-nine women with PCOS aged 17 to 27 years and 26 healthy nonhyperandrogenic volunteers with regular menses (control women aged 16 to 28 years were enrolled. All PCOS patients were overweight or obese (body mass index [BMI] ≥ 25. Diagnosis of PCOS was performed in line with the 2003 Rotterdam ESHRE/ASRM-Sponsored PCOS Consensus Workshop Group. Accordingly, PCOS was defined when at least two of the following three features were present after exclusion of other etiologies: 1 oligomenorrhea and or anovulation; 2 hyperandrogenism and/or hyperandrogenemia; and 3 polycystic ovaries visible at ultrasound. Androgen excess or related disorders were excluded. The intima-media thickness (IMT of common carotid arteries and common femoral arteries and the anteroposterior diameter of the infrarenal abdominal aorta were measured by ultrasound. Lutenizing hormone (LH, follicle-stimulating hormone (FSH, estradiol, total testosterone, androstenedione, and sex hormone-binding globulin (SHBG serum levels were measured between the 3rd and the 6th day of spontaneous or progestin-induced menstrual cycle. Our study was performed in the absence of any medical treatment. Results: Women with PCOS showed a higher LH to FSH ratio (p < 0.01, increased fasting insulin (p < 0.001, total testosterone (p < 0.001, and androstenedione (p < 0.001 levels, and lower

  11. Outcome of Pregnancies After Balloon Occlusion of the Infrarenal Abdominal Aorta During Caesarean in 230 Patients With Placenta Praevia Accreta

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Qinghua, E-mail: qh-wu77@163.com [The First Affiliated Hospital of Zhengzhou University, Departments of Prenatal Diagnosis, and Obstetrics, Obstetric Critical Treatment Center of Henan Province (China); Liu, Zhuan, E-mail: liuchuan2015ck@163.com; Zhao, Xianlan, E-mail: zxl121292014@163.com; Liu, Cai, E-mail: liucai2015ck@163.com [The First Affiliated Hospital of Zhengzhou University, Obstetric Critical Treatment Center of Henan Province, Department of Obstetrics (China); Wang, Yanli, E-mail: wangyanli2015yfy@163.com; Chu, Qinjun, E-mail: chuqinjun2015@163.com [The First Affiliated Hospital of Zhengzhou University, Department of Anesthesiology (China); Wang, Xiaojuan, E-mail: wangxiaojun2015ck@163.com; Chen, Zhimin, E-mail: chenzhimin2015ck@163.com [The First Affiliated Hospital of Zhengzhou University, Obstetric Critical Treatment Center of Henan Province, Department of Obstetrics (China)

    2016-11-15

    PurposeTo explore the efficacy and safety of prophylactic temporary balloon occlusion of the infrarenal abdominal aorta during caesarean for the management of patients with placenta praevia accreta.MethodsTwo hundred and sixty-eight cases of placenta praevia accreta from January 2012 to June 2015 were retrospectively reviewed. Group A included two hundred and thirty patients who underwent prophylactic temporary balloon occlusion of infrarenal abdominal aorta followed by caesarean section. Group B included thirty-eight patients who underwent caesarean without endovascular intervention. The parameters including operating room time, estimated blood loss, blood transfusion volume, PT (prothrombin time) during operation, days in the intensive care unit, and total hospital days were compared between the two groups.ResultsThe operating room time, estimated blood loss, PT, the incidence of hysterectomy, blood transfusion volume, postpartum haemorrhage, and days in intensive care unit were lower in group A than in group B, with statistical significance (P < 0.05). There was no significant difference in the Apgar scores of the neonates and the incidences of thrombosis in lower limbs between the two groups (P > 0.05). No patient in the group with prophylactic temporary balloon occlusion of the infrarenal abdominal aorta was performed hysterectomy, while three patients in group B were performed hysterectomy because of uncontrollable haemorrhage.ConclusionsThe results indicate that prophylactic temporary balloon occlusion of infrarenal abdominal aorta followed by caesarean section is safe and effective to control intraoperative blood loss and greatly decreases the risk of hysterectomy in patients with placenta praevia accreta.

  12. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subcla...

  13. Prosthetic valve sparing aortic root replacement: an improved technique.

    Science.gov (United States)

    Leacche, Marzia; Balaguer, Jorge M; Umakanthan, Ramanan; Byrne, John G

    2008-10-01

    We describe a modified surgical technique to treat patients with a previous history of isolated aortic valve replacement who now require aortic root replacement for an aneurysmal or dissected aorta. This technique consists of replacing the aortic root with a Dacron conduit, leaving intact the previously implanted prosthesis, and re-implanting the coronary arteries in the Dacron graft. Our technique differs from other techniques in that we do not leave behind any aortic tissue remnant and also in that we use a felt strip to obliterate any gap between the old sewing ring and the newly implanted graft. In our opinion, this promotes better hemostasis. We demonstrate that this technique is safe, feasible, and results in acceptable outcomes.

  14. Early experience with transfemoral endovascular aneurysm management (TEAM) in the treatment of aortic aneurysms

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; May, J.; Bell, P. R.; Swedenborg, J.; Collin, J.

    1996-01-01

    OBJECTIVES: To evaluate the early experience with transfemoral endovascular aortic aneurysm management using the Endovascular Grafting System. DESIGN: Multi-centre prospective evaluation of the implantation procedure and early results (median follow-up 153 days). SETTING: Department of Surgery,

  15. Endovascular management of lap belt-related abdominal aortic injury in a 9-year-old child.

    Science.gov (United States)

    Papazoglou, Konstantinos O; Karkos, Christos D; Kalogirou, Thomas E; Giagtzidis, Ioakeim T

    2015-02-01

    Blunt abdominal aortic trauma is a rare occurrence in children with only a few patients having been reported in the literature. Most such cases have been described in the context of lap belt injuries. We report a 9-year-old boy who suffered lap belt trauma to the abdomen during a high-speed road traffic accident resulting to the well-recognized pattern of blunt abdominal injury, that is, the triad of intestinal perforation, fractures of the lumbar spine, and abdominal aortic injury. The latter presented with lower limb ischemia due to dissection of the infrarenal aorta and right common iliac artery. Revascularization was achieved by endovascular means using 2 self-expanding stents in the infrarenal aorta and the right common iliac artery. This case is one of the few reports of lap belt-related acute traumatic abdominal aortic dissection in a young child and highlights the feasibility of endovascular management in the pediatric population. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  17. Follow-up on Small Abdominal Aortic Aneurysms Using Three Dimensional Ultrasound

    DEFF Research Database (Denmark)

    Ghulam, Q. M.; Bredahl, K. K.; Lönn, L.

    2017-01-01

    Objectives Rupture risk in abdominal aortic aneurysms (AAAs) is assessed using AAA diameter; yet 10% of ruptures occur in a small aneurysm. This underlines the inadequacy of diameter as a standalone parameter. In this prospective follow-up study, ultrasound determined aneurysm diameter was compared...... with aneurysm volume determined by three dimensional ultrasound (3D-US) in a group of 179 AAAs. Design This was a prospective cohort study with repeated diameter and volume measurements by 3D-US. Material and methods In total, 179 patients with small infrarenal AAAs (diameter 30–55 mm) were enrolled......L) were recorded. In post-hoc analysis, it was found that more AAAs with a stable diameter and a growing volume than AAAs with a stable diameter and volume were undergoing aortic repair during follow-up, based on the maximum diameter. Conclusion In this cohort of small AAAs, 40% of patients with a stable...

  18. [Long-term outcome of aortic valve sparing procedures in connective tissue disorders].

    Science.gov (United States)

    Tanaka, Hiroshi; Ogino, H; Matsuda, H; Minatoya, K; Sasaki, N

    2009-10-01

    The aim of this study is to determine the long-term outcome of aortic valve sparing procedures for patients having connective tissue disorder. Between 1993 and 2008, the aortic valve sparing surgery was performed in 94 patients having aortic root dilatation. Eighty patients of them (37.2 +/- 13.4 years, 50 male) had cystic medial necrosis in the aortic wall, which was confirmed the pathological examination. We reviewed these patients. Sixty percent (48/80) had Marfan syndrome, 5% (4/80) had Loeyz-Dietz syndrome, 2% (2/80) had bicuspid aortic valve, and 11% (9/80) had aortic dissection. Our reimplantation procedure has been refined as followed: with a tube graft in 41, a tube graft with creation of neo-sinuses in 11, and a Valsalva graft in 14. Fourteen patients underwent the remodeling procedure. The follow-up rate was 100% with the duration of 3.7+/- 3.4 years. There were no operative death but six late deaths. Seventeen (21.3%) patients required aortic valve replacement, for recurrent aortic insufficiency in 13 and infection in 4. Freedom from reoperation was 80%, 43%, and freedom from moderate or severe aortic insufficiency was 80%, 54%, at 5 and 10 years, respectively. Pathological findings of the aortic valve obtained in the reoperations showed elongation and prolapse of the aortic valve due to myxomatous degeneration and fibrous thickening caused by aortic insufficiency. Even in connective tissue disorders, aortic valve sparing operation is associated with acceptable long-term durability, although cusp degeneration resulting in recurrent aortic insufficiency might be progressive.

  19. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  20. Skin Graft

    OpenAIRE

    Shimizu, Ruka; Kishi, Kazuo

    2012-01-01

    Skin graft is one of the most indispensable techniques in plastic surgery and dermatology. Skin grafts are used in a variety of clinical situations, such as traumatic wounds, defects after oncologic resection, burn reconstruction, scar contracture release, congenital skin deficiencies, hair restoration, vitiligo, and nipple-areola reconstruction. Skin grafts are generally avoided in the management of more complex wounds. Conditions with deep spaces and exposed bones normally require the use o...

  1. Coronary artery narrowing after aortic root reconstruction with resorcin-formalin glue.

    Science.gov (United States)

    Martinelli, L; Graffigna, A; Guarnerio, M; Bonmassari, R; Disertori, M

    2000-11-01

    Severe stenosis of right and left main coronary artery ostia developed after aortic root reconstruction with gelatin-resorcin-formol glue for correction of acute type A aortic dissection. Surgical treatment of this condition required grafting of the right and left anterior descending arteries with bilateral mammary arteries on the beating heart.

  2. 18F-FDG PET-CT uptake is a feature of both normal diameter and aneurysmal aortic wall and is not related to aneurysm size

    International Nuclear Information System (INIS)

    Barwick, Tara D.; Lyons, O.T.A.; Waltham, M.; Mikhaeel, N.G.; O'Doherty, M.J.

    2014-01-01

    Aortic metabolic activity is suggested to correlate with presence and progression of aneurysmal disease, but has been inadequately studied. This study investigates the 2-[ 18 F] fluoro-2-deoxy-D-glucose ( 18 F-FDG) uptake in a population of infra-renal abdominal aortic aneurysms (AAA), compared to a matched non-aneurysmal control group. The Positron Emission Tomography - Computed Tomography (PET/CT) database was searched for infra-renal AAA. Exclusion criteria were prior repair, vasculitis, and saccular/mycotic thoracic or thoraco-abdominal aneurysms. Matching of 159 non-aneurysmal ( max ) and target to background mediastinal blood pool ratio (TBR) were documented. Predictors of FDG uptake (age, sex, aortic diameter, hypertension, statin use, and diabetes) were assessed using univariate analysis. Follow-up questionnaires were sent to referring clinicians. Aneurysms (n = 151) and controls (n = 159) were matched (p > 0.05) for age, sex, diabetes, hypertension, smoking status, statin use, and indication for PET/CT. Median aneurysm diameter was 5.0 cm (range 3.2-10.4). On visual analysis there was no significant difference in the overall numbers with increased visual uptake 24 % (36/151) in the aneurysm group vs. 19 % (30/159) in the controls, p = ns. SUV max was slightly lower in the aneurysm group vs. controls (mean (2 SD) 1.75(0.79) vs. 1.84(0.58), p = 0.02). However there was no difference in TBR between the AAA group and controls (mean (2 SD) 1.03 (0.46) vs. 1.05(0.31), p = 0.36). During a median 18 (interquartile range 8-35) months' follow-up 20 were repaired and four were confirmed ruptured. The level of metabolic activity as assessed by 18 F-FDG PET/CT in infra-renal AAA does not correlate with aortic size and does not differ between aneurysms and matched controls. (orig.)

  3. Aortic dissection. Basic aspects and endovascular management

    International Nuclear Information System (INIS)

    Jaramillo, Nicolas I; Alviar, Carlos I

    2005-01-01

    Treatment of thoracic aortic pathology is complicated by the morbidity associated to the surgical procedure and to the frailty of an elderly and difficult population. Surgical operation in this kind of population frequently bears a significant incidence of death and long-term disability. In an effort to reduce the incidence of negative outcomes, minimally invasive techniques in the form of endovascular stenting have been introduced during the past decade. The technology, originally described by Parodi, and initially designed for its use in abdominal aortic aneurysms, has been adapted for the treatment of thoracic aortic aneurysms. Furthermore, an improved understanding of the pathophysiology and the natural history of thoracic aortic disease as well as the analysis of the outcomes have facilitated our treatment decisions in terms of the timing for an appropriate intervention. Treatment of thoracic aortic dissection using endovascular Stent is one of the more recent advances in this condition and is receiving increasing attention, as it is a less invasive alternative to an open surgical repair. Although this technology is still innovative, significant improvements have been made lately in the design and deployment of the endovascular Stent-grafts. These prostheses have been increasingly used to treat aneurysms, dissections and traumatic ruptures, as well as giant penetrating ulcers and intramural hematomas of the descending thoracic aorta with good early and mid-term outcomes. The rareness, complexity and severity of the pathology and the theoretically high risk of complications should render the surgeon extremely cautious especially with young patients. Conceptually, the endo luminal treatment in the acute phase seems to be the solution and will probably become a preferred therapy while technical refinement is under way. Worldwide experience is growing and with this a better understanding of the indications and limitations of this innovative therapy will be

  4. Total Percutaneous Aortic Repair: Midterm Outcomes

    International Nuclear Information System (INIS)

    Bent, Clare L.; Fotiadis, Nikolas; Renfrew, Ian; Walsh, Michael; Brohi, Karim; Kyriakides, Constantinos; Matson, Matthew

    2009-01-01

    The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 ± 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 ± 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.

  5. Acute Type A Aortic Dissection Successfully Managed with One-stage Surgery of Total Aortic Arch Replacement with Supra-aortic Transposition Plus Frozen Elephant Trunk Technique

    Directory of Open Access Journals (Sweden)

    Meng-Lin Lee

    2014-09-01

    Full Text Available Acute type A aortic dissection has long been a challenging issue. The surgical techniques traditionally vary with the anatomic extent of the aortic dissection. Simple ascending aortic grafting can be lifesaving, but the lesions beyond the aorta, which include the arch vessels and descending aorta, remain potential hazards. In this paper, we present a patient in which acute type A aortic dissection with lesions extending into descending thoracic aorta was successfully managed by total arch replacement with supra-aortic transposition plus the frozen elephant trunk technique to the descending aorta. A 67-year-old gentleman presented with severe tearing pain from the anterior to posterior chest. Computed tomography confirmed the diagnosis of acute type A dissection extending to the level of the right common iliac artery. An emergent operation was performed as in the aforementioned technique. The surgery went well and the patient was discharged without comorbidities on postoperative day 25. The patient had regular outpatient clinical follow-up. The follow-up computed tomography images showed adequate results with the obliteration of the false lumen. In conclusion, total aortic arch replacement with supra-aortic transposition plus frozen elephant trunk technique is a safe and feasible operative method for patients with detrimental acute type A aortic dissection.

  6. Atheroembolization and potential air embolization during aortic declamping in open repair of a pararenal aortic aneurysm: A case report.

    Science.gov (United States)

    Dregelid, Einar Børre; Lilleng, Peer Kåre

    2016-01-01

    When ischemic events ascribable to microembolization occur during open repair of proximal abdominal aortic aneurysms, a likely origin of atheroembolism is not always found. A 78-year old man with enlargement of the entire aorta underwent open repair for a pararenal abdominal aortic aneurysm using supraceliac aortic clamping for 20min. Then the graft was clamped, the supraceliac clamp was removed, and the distal and right renal anastomoses were also completed. The patient was stable throughout the operation with only transient drop in blood pressure on reperfusion. Postoperatively the patient developed ischemia, attributable to microembolization, in legs, small intestine, gall bladder and kidneys. He underwent fasciotomy, small bowel and gall bladder resections. Intestinal absorptive function did not recover adequately and he died after 4 months. Microscopic examination of hundreds of intestinal, juxtaintestinal mesenteric, and gall bladder arteries showed a few ones containing cholesterol emboli. It is unsure whether a few occluded small arteries out of several hundred could have caused the ischemic injury alone. There had been only moderate backbleeding from aortic branches above the proximal anastomosis while it was sutured. Inadvertently, remaining air in the graft, aorta, and aortic branches may have been whipped into the pulsating blood, resulting in air microbubbles, when the aortic clamp was removed. Although both atheromatous particles and air microbubbles are well-known causes of iatrogenic microembolization, the importance of air microembolization in open repair of pararenal aortic aneurysms is not known and need to be studied. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Surgical and Antimicrobial Treatment of Prosthetic Vascular Graft Infections at Different Surgical Sites: A Retrospective Study of Treatment Outcomes

    Science.gov (United States)

    Elzi, Luigia; Gurke, Lorenz; Battegay, Manuel; Widmer, Andreas F.; Weisser, Maja

    2014-01-01

    Objective Little is known about optimal management of prosthetic vascular graft infections, which are a rare but serious complication associated with graft implants. The goal of this study was to compare and characterize these infections with respect to the location of the graft and to identify factors associated with outcome. Methods This was a retrospective study over more than a decade at a tertiary care university hospital that has an established multidisciplinary approach to treating graft infections. Cases of possible prosthetic vascular graft infection were identified from the hospital's infectious diseases database and evaluated against strict diagnostic criteria. Patients were divided into groups according to the locations of their grafts: thoracic-aortic, abdominal-aortic, or peripheral-arterial. Statistical analyses included evaluation of patient and infection characteristics, time to treatment failure, and factors associated specifically with cure rates in aortic graft infections. The primary endpoint was cure at one year after diagnosis of the infection. Results Characterization of graft infections according to the graft location did show that these infections differ in terms of their characteristics and that the prognosis for treatment seems to be influenced by the location of the infection. Cure rate and all-cause mortality at one year were 87.5% and 12.5% in 24 patients with thoracic-aortic graft infections, 37.0% and 55.6% in 27 patients with abdominal-aortic graft infections, and 70.0% and 30.0% in 10 patients with peripheral-arterial graft infections. In uni- and multivariate analysis, the type of surgical intervention used in managing infections (graft retention versus graft replacement) did not affect primary outcome, whereas a rifampicin-based antimicrobial regimen was associated with a higher cure rate. Conclusions We recommend that future prospective studies differentiate prosthetic vascular graft infections according to the location of the

  8. 18F-FDG PET-CT uptake is a feature of both normal diameter and aneurysmal aortic wall and is not related to aneurysm size

    Energy Technology Data Exchange (ETDEWEB)

    Barwick, Tara D. [Imperial College Healthcare NHS Trust, Charing Cross Hospital, Department of Radiology/Nuclear Medicine, London (United Kingdom); Hammersmith Hospital, Department of Surgery and Cancer, Imperial College London, London (United Kingdom); Lyons, O.T.A.; Waltham, M. [King' s College London, BHF Centre of Research Excellence and NIHR Biomedical Research Centre at King' s Health Partners, Academic Department of Surgery, London (United Kingdom); Mikhaeel, N.G. [Guy' s and St Thomas' Foundation NHS Trust, Department of Oncology, London (United Kingdom); O' Doherty, M.J. [King' s Health Partners, Clinical PET Centre, St Thomas' Hospital, London (United Kingdom)

    2014-12-15

    Aortic metabolic activity is suggested to correlate with presence and progression of aneurysmal disease, but has been inadequately studied. This study investigates the 2-[{sup 18}F] fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) uptake in a population of infra-renal abdominal aortic aneurysms (AAA), compared to a matched non-aneurysmal control group. The Positron Emission Tomography - Computed Tomography (PET/CT) database was searched for infra-renal AAA. Exclusion criteria were prior repair, vasculitis, and saccular/mycotic thoracic or thoraco-abdominal aneurysms. Matching of 159 non-aneurysmal (<3 cm diameter) controls from the same population was assessed. Infra-renal aortic wall FDG uptake was assessed using visual analysis; maximum standardized uptake value (SUV{sub max}) and target to background mediastinal blood pool ratio (TBR) were documented. Predictors of FDG uptake (age, sex, aortic diameter, hypertension, statin use, and diabetes) were assessed using univariate analysis. Follow-up questionnaires were sent to referring clinicians. Aneurysms (n = 151) and controls (n = 159) were matched (p > 0.05) for age, sex, diabetes, hypertension, smoking status, statin use, and indication for PET/CT. Median aneurysm diameter was 5.0 cm (range 3.2-10.4). On visual analysis there was no significant difference in the overall numbers with increased visual uptake 24 % (36/151) in the aneurysm group vs. 19 % (30/159) in the controls, p = ns. SUV{sub max} was slightly lower in the aneurysm group vs. controls (mean (2 SD) 1.75(0.79) vs. 1.84(0.58), p = 0.02). However there was no difference in TBR between the AAA group and controls (mean (2 SD) 1.03 (0.46) vs. 1.05(0.31), p = 0.36). During a median 18 (interquartile range 8-35) months' follow-up 20 were repaired and four were confirmed ruptured. The level of metabolic activity as assessed by {sup 18}F-FDG PET/CT in infra-renal AAA does not correlate with aortic size and does not differ between aneurysms and matched controls

  9. Aortic Annular Enlargement during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Selman Dumani

    2016-09-01

    Full Text Available In the surgery of aortic valve replacement is always attempted, as much as possible, to implant the larger prosthesis with the mains goals to enhance the potential benefits, to minimise transvalvular gradient, decrease left ventricular size and avoid the phenomenon of patient-prosthesis mismatch. Implantation of an ideal prosthesis often it is not possible, due to a small aortic annulus. A variety of aortic annulus enlargement techniques is reported to avoid patient-prosthesis mismatch. We present the case that has submitted four three times open heart surgery. We used Manouguian technique to enlarge aortic anulus with excellent results during the fourth time of surgery.

  10. Extended aortic repair using frozen elephant trunk technique for Marfan syndrome with acute aortic dissection.

    Science.gov (United States)

    Uchida, Naomichi; Katayama, Akira; Kuraoka, Masatsugu; Katayama, Keijiro; Takahashi, Shinya; Takasaki, Taiichi; Sueda, Taijiro

    2013-01-01

    The aim of this study was to analyze midterm results of frozen elephant trunk technique for Marfan syndrome with acute aortic dissection. Between February 1999 and August 2011 we performed arch replacement uisng frozen elephant trunk technique for acute aortic dissection in 8 patients with Marfan syndrome containing two complicated type B dissections and six type A dissections.Five patients compromised annulo-aortic ectasia who performed Bentall operation. No patients died in the initial operation. Fate of false lumen on the stent graft border was expressed by CT scan follow-up that were patent in 0, thrombosis in 5 and absorption in 3 patients. One patient who had new aortic dissection 8 years after initial surgery required the Crawford V operation. Ten-years-survival rate was 100% and ten years-event free rate was 67%. Frozen elephant trunk technique was feasible for Marfan syndrome with acute aortic dissection and might become alternative prophylactic treatment to the downstream aorta for acute aortic dissection.

  11. Pancreas grafts

    International Nuclear Information System (INIS)

    Hahn, D.; Buell, U.; Land, W.; Unertl, K.

    1981-01-01

    Perfusion studies with sup(99m)Tc-DTPA, which has hitherto been used routinely to investigate renal grafts, have also proved useful for monitoring the perfusion of pancreas grafts. A total perfusion failure is equally reliably demonstrable as in renal grafts. Quantitatively smaller perfusion alterations can be demonstrated by monitoring the course. It seems possible to differentiate the salivary edema of a rejection reaction, well known from animal experiments, with the help of other paramters (e.g. creatinine). Further clinical studies are however necessary to confirm these results. (orig.) [de

  12. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  13. Abdominal Aortic Aneurysm (AAA)

    Science.gov (United States)

    ... Professions Site Index A-Z Abdominal Aortic Aneurysm (AAA) Abdominal aortic aneurysm (AAA) occurs when atherosclerosis or plaque buildup causes the ... weak and bulge outward like a balloon. An AAA develops slowly over time and has few noticeable ...

  14. Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

    International Nuclear Information System (INIS)

    Riga, Celia V.; Bicknell, Colin D.; Wallace, Daniel; Hamady, Mohamad; Cheshire, Nicholas

    2009-01-01

    To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

  15. [Surgical results for aortic involvement in Marfan syndrome].

    Science.gov (United States)

    Shiiya, N; Matsuzaki, K; Maruyama, R; Kunihara, T; Murashita, T; Aoki, H; Yasuda, K

    2002-07-01

    From 1991 through 2001, 21 Marfan patients underwent aortic operations in our hospital. They received a total of 36 aortic operations, 31 by ourselves including 4 non-elective operations and 2 operations before 1991. Extent of replacement was Bentall + total arch (4), Bentall (8), valve sparing aortic root (reimplantation) (2), re-anastomosis + coronary aortic bypass grafting (CABG) after Bentall (1), ascending + total arch (3), ascending (1), total arch (1), total thoracoabdominal (10), thoracoabdominal (1), descending thoracic (2), distal arch (1), abdominal (2). Multiple operations were required in 11 patients (2 operations in 7, 3 operations in 4). Eight reoperations in 6 patients were for adjacent lesion, 5 reoperations were for remote lesion, and 2 others were for complication of Bentall (initial operation elsewhere). Among the 8 reoperations for adjacent lesion, 3 were scheduled operation (2 with elephant trunk), 4 were for residual dissection, and 1 was for annulo-aortic ectasia (AAE). Total aortic replacement was achieved in 4 and subtotal replacement excluding the root in 2. There was no hospital mortality. Paraparesis occurred in 1 who died 4.7 years after operation. The remaining patients are currently alive. No other aortic event occurred. Aortic reoperation-free survival was 83% at 5 year and 28% at 10 year.

  16. Infra-renal angles, entry into inferior vena cava and vertebral levels of renal veins.

    Science.gov (United States)

    Satyapal, K S

    1999-10-01

    Current norms for renal vasculature hold true in only half the population. Standard textbooks perpetuate old misconceptions regarding renal venous anatomy. This study is aimed to determine left and right infra-renal angles (L-IRA, R-IRA); entry level of renal veins into the inferior vena cava (IVC), and height of IVC under renal vein influence; and their vertebral level. One hundred morphologically normal en-bloc renal specimens randomly selected from post-mortem examinations were dissected and resin casted. IRA were also measured from venograms of 32 adult and 11 foetal cadavers, as were vertebral entry levels. IRA measurements (degrees) were as follows: left, 55 degrees +/- 16 degrees (20 degrees -102 degrees ); right, 60 degrees +/- 17 degrees (10 degrees -93 degrees ). Left vein entered IVC higher than right 54%, lower 36%, and opposite each other 10%. Vertical distance between lower borders of veins was 1.0 +/- 0.9 cm. Vertical distance of IVC under renal vein influence was 2.3 +/- 1.0 cm. Vertebral level of veins in adults lies between TI2-L2. In foetuses, IRA was as follows: left, 65 degrees +/- 12 degrees (45 degrees -90 degrees ); right, 58 degrees +/- 7 degrees (40 degrees -70 degrees ); vertebral level between T12 and L3. Similar IRA values from literature noted on right, 51 degrees (26 degrees -100 degrees ); differences on left, 77 degrees (43 degrees -94 degrees ), clearly differing from Williams et al. (Gray's Anatomy, 37(th) ed, 1989) statement that renal veins "open into the inferior vena cava almost at right angles." Large variations of IRA are not surprising since kidneys are considered normally "floating viscera," varying position with posture and respiratory movement as well as in live vs. cadaveric subjects. The entry level into the IVC also differs from Williams et al. This study uniquely quantitated actual height difference between lower borders of left and right veins. The data presented appears to be the first documentation of vertebral

  17. A rare cause of lomber pain: diopatic abdominal aortic pseudoaneurysm

    International Nuclear Information System (INIS)

    Colak, F.; Saglam, M.; Sahin, M.; Bozlar, U.

    2012-01-01

    Full text: Introduction: Abdominal aortic pseudoaneurysms are rare and life-threatening situations. Trauma and operative procedures are common causes of pseudoaneurysm. Abdominal pain is the most common symptom of them. They are usually detected incidentally. Objectives and tasks: We aim to present CTA findings of abdominal aortic pseudoaneurysm causes gradually increasing lomber pain in 70-year-old female patient. Physical examination also made diagnosis easy because of pulsatile mass detected. Materials and methods: Lomber MRG and endoscopic procedures were normal. Then we performed CTA to find the cause for pulsatile mass. Results: Pseudoaneurysm with approximately 6 x 7.5 cm size was compressing duodenum and not showing extravasation at the infrarenal segment of abdominal aorta detected in CTA. Pseudoaneurysm was filling from aorta through a 2 cm neck. Conclusion: Primary cause for pseudoaneurysms is traumating injuries. Initial presentation may be abdominal pain, gastrointestinal bleeding or pulsatile mass. To plan treatment and figure out pseudoaneurysm CTA is very fast and non-invasive technic

  18. Minocycline Effectively Protects the Rabbit's Spinal Cord From Aortic Occlusion-Related Ischemia.

    Science.gov (United States)

    Drenger, Benjamin; Fellig, Yakov; Ben-David, Dror; Mintz, Bella; Idrees, Suhel; Or, Omer; Kaplan, Leon; Ginosar, Yehuda; Barzilay, Yair

    2016-04-01

    To identify the minocycline anti-inflammatory and antiapoptotic mechanisms through which it is believed to exert spinal cord protection during aortic occlusion in the rabbit model. An animal model of aortic occlusion-related spinal cord ischemia. Randomized study with a control group and pre-ischemia and post-ischemia escalating doses of minocycline to high-dose minocycline in the presence of either hyperglycemia, a pro-apoptotic maneuver, or wortmannin, a specific phosphatidylinositol 3-kinase antagonist. Tertiary medical center and school of medicine laboratory. Laboratory animals-rabbits. Balloon obstruction of infrarenal aorta introduced via femoral artery incision. Severe hindlimb paralysis (mean Tarlov score 0.36±0.81 out of 3) was observed in all the control group animals (9 of 11 with paraplegia and 2 of 11 with paraparesis) compared with 11 of 12 neurologically intact animals (mean Tarlov score 2.58±0.90 [p = 0.001 compared with control]) in the high-dose minocycline group. This protective effect was observed partially during a state of hyperglycemia and was completely abrogated by wortmannin. Minocycline administration resulted in higher neurologic scores (p = 0.003) and a shift to viable neurons and more apoptotic-stained nuclei resulting from reduced necrosis (p = 0.001). In a rabbit model of infrarenal aortic occlusion, minocycline effectively reduced paraplegia by increasing the number of viable neurons in a dose-dependent manner. Its action was completely abrogated by inhibiting the phosphatidylinositol 3-kinase pathway and was inhibited partially by the pro-apoptotic hyperglycemia maneuver, indicating that the activation of cell salvage pathways and mitochondrial sites are possible targets of minocycline action in an ischemic spinal cord. Copyright © 2016. Published by Elsevier Inc.

  19. Long-term results of aortic root repair using the reimplantation technique.

    Science.gov (United States)

    David, Tirone E; Armstrong, Susan; Manlhiot, Cedric; McCrindle, Brian W; Feindel, Christopher M

    2013-03-01

    Aortic valve sparing is frequently performed to treat patients with aortic root aneurysm, but there is an inadequate amount of information regarding its long-term durability. This study examines the long-term results of reimplantation of the aortic valve in patients with aortic root aneurysms. From August 1989 to December 2010, 296 consecutive patients had reimplantation of the aortic valve into a tubular Dacron graft. Their mean age was 45 years (range, 11-79 years), and 78% were men. Of the patients, 36% had Marfan syndrome and 11% had bicuspid aortic valve. Patients were followed prospectively with periodic images of the aortic root and remaining aorta. The mean follow-up was 6.9 ± 4.5 years. There were 21 patients at risk at 15 years. There were 4 operative and 18 late deaths. The survival at 5, 10, and 15 years was 95.1% ± 3.5%, 93.1% ± 4.4%, and 76.5% ± 18%, respectively. Only 3 patients required reoperation on the aortic valve; all 3 patients had the Bentall procedure. Freedom from reoperation at 5, 10, and 15 years was 99.7% ± 2.0%, 97.8% ± 5.3%, and 97.8% ± 5.3%, respectively. During follow-up, moderate aortic insufficiency developed in 9 patients, and severe aortic insufficiency developed in 2 patients. Freedom from moderate or severe aortic insufficiency at 5, 10, and 15 years was 98.3% ± 3.5%, 92.9% ± 6.5%, and 89.4% ± 12%, respectively. The function of the aortic valve implanted inside a tubular Dacron graft remains normal at 15 years in most patients after this type of aortic valve-sparing operation. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  20. Infolding of fenestrated endovascular stent graft.

    Science.gov (United States)

    Zelt, Jason G E; Jetty, Prasad; Hadziomerovic, Adnan; Nagpal, Sudhir

    2017-09-01

    We report a case of infolding of a fenestrated stent graft involving the visceral vessel segment after a juxtarenal abdominal aorta aneurysm repair. The patient remains free of any significant endoleak, and the aortic sac has shown regression. The patient remains asymptomatic, with no abdominal pain, with normal renal function, and without ischemic limb complications. We hypothesize that significant graft oversizing (20%-30%) with asymmetric engineering of the diameter-reducing ties may have contributed to the infolding. Because of the patient's asymptomatic nature and general medical comorbidities, further intervention was deemed inappropriate as the aneurysmal sac is regressing despite the infolding.

  1. A Case of an Aortic Abscess around the Elephant Trunk.

    Science.gov (United States)

    Fujii, Takeshiro; Kawasaki, Muneyasu; Katayanagi, Tomoyuki; Okuma, Shinnosuke; Masuhara, Hiroshi; Shiono, Noritsugu; Watanabe, Yoshinori

    2015-01-01

    A 52-year-old male patient with a history of total arch replacement using the elephant trunk technique for acute aortic dissection 4 years before visited our hospital with the chief complaint of persistent fever. Chest computed tomography (CT) suggested prosthetic vascular graft infection, which was treated surgically after chemotherapy. The first surgery consisted of debridement of an abscess around the vascular graft and in the aorta around the elephant trunk, and thoracic descending aorta replacement and vacuum-assisted closure (VAC) in view of the risk of bleeding from the peripheral region of the elephant trunk. One week later, omental filling was performed as the second step. This is a very rare case of aortic abscess around the elephant trunk that could successfully be managed by graft-conserving treatment.

  2. Controlled reperfusion decreased reperfusion induced oxidative stress and evoked inflammatory response in experimental aortic-clamping animal model.

    Science.gov (United States)

    Jancsó, G; Arató, E; Hardi, P; Nagy, T; Pintér, Ö; Fazekas, G; Gasz, B; Takacs, I; Menyhei, G; Kollar, L; Sínay, L

    2016-09-12

    Revascularization after long term aortic ischaemia in vascular surgery induces reperfusion injury accompanied with oxidative stress and inflammatory responses. The hypothesis of this study was that the aortic occlusion followed by controlled reperfusion (CR) can reduce the ischaemia-reperfusion injury, the systemic and local inflammatory response induced by oxidative stress.Animal model was used. animals underwent a 4-hour infrarenal aortic occlusion followed by continuous reperfusion. Treated group: animals were treated with CR: after a 4-hour infrarenal aortic occlusion we made CR for 30 minutes with the crystalloid reperfusion solution (blood: crystalloid solution ratio 1:1) on pressure 60 Hgmm. Blood samples were collected different times. The developing oxidative stress was detected by the plasma levels of malondialdehyde, reduced glutathion, thiol groups and superoxide dismutase. The inflammatory response was measured by phorbol myristate acetate-induced leukocyte reactive oxygen species production and detection of change in myeloperoxidase levels. The animals were anaesthetized one week after terminating ligation and biopsy was taken from quadriceps muscle and large parenchymal organs.CR significantly reduced the postischaemic oxydative stress and inflammatory responses in early reperfusion period. Pathophysiological results: The rate of affected muscle fibers by degeneration was significantly higher in the untreated animal group. The infiltration of leukocytes in muscle and parenchymal tissues was significantly lower in the treatedgroup.CR can improve outcome after acute lower-limb ischaemia. The results confirm that CR might be also a potential therapeutic approach in vascular surgery against reperfusion injury in acute limb ischaemia. Supported by OTKA K108596.

  3. One-stage surgery in combination with thoracic endovascular grafting and resection of T4 lung cancer invading the thoracic aorta and spine

    OpenAIRE

    Sato, Seijiro; Goto, Tatsuya; Koike, Terumoto; Okamoto, Takeshi; Shoji, Hirokazu; Ohashi, Masayuki; Watanabe, Kei; Tsuchida, Masanori

    2017-01-01

    A novel strategy of one-stage surgery in combination with thoracic endovascular grafting and resection for T4 lung cancer invading the thoracic aorta and spine is described. A 56-year-old man with locally advanced lung cancer infiltrating the aortic wall and spine underwent neoadjuvant chemotherapy and thoracic irradiation, followed by en bloc resection of the aortic wall and spine with thoracic endovascular grafting. He developed postoperative chylothorax, but there were no stent graft-relat...

  4. Aortic replacement in aorto-occlusive disease: an observational study

    Directory of Open Access Journals (Sweden)

    Winter Richard K

    2008-10-01

    Full Text Available Abstract Background For many patients with aorto-occlusive disease, where stent deployment is not possible, surgery remains the only treatment option available. The aim of this study was to assess the results of aortic reconstruction surgery performed in patients with critical ischaemia. Methods All patients with critical ischaemia undergoing surgery during 1991–2004 were identified from a prospectively maintained database. Mortality data was verified against death certificate data. Demographic and clinical data were obtained from the clinical notes and the radiology database. Disease was classified as: type I – limited to aorta and common iliac arteries; type II – external iliac disease and type III combined aortic, iliac and infra-inguinal disease. Results 86 patients underwent aortic replacement surgery all of whom had critical ischaemia consisting of: type I (n = 16; type II (n = 37 and type III (n = 33. The 30-day mortality rate was 10.4%, the one-year patient survival was 80%, and the 1-year graft survival was 80%. At 2 years the actual patient survival was 73% and no additional graft losses were identified. All patients surviving 30 days reported excellent symptomatic relief. Early, complications occurred in 6 (7% patients: thrombosis within diseased superficial femoral arteries (n = 4; haemorrhage and subsequent death (n = 2. Ten (14% late complications (> 12 months occurred in the 69 surviving patients and included: anastomotic stenosis (n = 3; graft thrombosis (n = 4, graft infection (n = 3. Four patients developed claudication as a result of more distal disease in the presence of a patent graft, and 1 patient who continued smoking required an amputation for progressive distal disease. Conclusion Aortic reconstruction for patients with extensive aorto-occlussive disease provides long-standing symptomatic relief for the majority of patients. After the first year, there is continued patient attrition due to co

  5. Endovascular Treatment of Late Thoracic Aortic Aneurysms after Surgical Repair of Congenital Aortic Coarctation in Childhood

    Science.gov (United States)

    Juszkat, Robert; Perek, Bartlomiej; Zabicki, Bartosz; Trojnarska, Olga; Jemielity, Marek; Staniszewski, Ryszard; Smoczyk, Wiesław; Pukacki, Fryderyk

    2013-01-01

    Background In some patients, local surgery-related complications are diagnosed many years after surgery for aortic coarctation. The purposes of this study were: (1) to systematically evaluate asymptomatic adults after Dacron patch repair in childhood, (2) to estimate the formation rate of secondary thoracic aortic aneurysms (TAAs) and (3) to assess outcomes after intravascular treatment for TAAs. Methods This study involved 37 asymptomatic patients (26 female and 11 male) who underwent surgical repair of aortic coarctation in the childhood. After they had reached adolescence, patients with secondary TAAs were referred to endovascular repair. Results Follow-up studies revealed TAA in seven cases (19%) (including six with the gothic type of the aortic arch) and mild recoarctation in other six (16%). Six of the TAA patients were treated with stentgrafts, but one refused to undergo an endovascular procedure. In three cases, stengrafts covered the left subclavian artery (LSA), in another the graft was implanted distally to the LSA. In two individuals, elective hybrid procedures were performed with surgical bypass to the supraaortic arteries followed by stengraft implantation. All subjects survived the secondary procedures. One patient developed type Ia endoleak after stentgraft implantation that was eventually treated with a debranching procedure. Conclusions The long-term course of clinically asymptomatic patients after coarctation patch repair is not uncommonly complicated by formation of TAAs (particularly in individuals with the gothic pattern of the aortic arch) that can be treated effectively with stentgrafts. However, in some patients hybrid procedures may be necessary. PMID:24386233

  6. Spinal cord ischemia after simultaneous and sequential treatment of multilevel aortic disease.

    Science.gov (United States)

    Piffaretti, Gabriele; Bonardelli, Stefano; Bellosta, Raffaello; Mariscalco, Giovanni; Lomazzi, Chiara; Tolenaar, Jip L; Zanotti, Camilla; Guadrini, Cristina; Sarcina, Antonio; Castelli, Patrizio; Trimarchi, Santi

    2014-10-01

    The aim of the present study is to report a risk analysis for spinal cord injury in a recent cohort of patients with simultaneous and sequential treatment of multilevel aortic disease. We performed a multicenter study with a retrospective data analysis. Simultaneous treatment refers to descending thoracic and infrarenal aortic lesions treated during the same operation, and sequential treatment refers to separate operations. All descending replacements were managed with endovascular repair. Of 4320 patients, multilevel aortic disease was detected in 77 (1.8%). Simultaneous repair was performed in 32 patients (41.5%), and a sequential repair was performed in 45 patients (58.4%). Postoperative spinal cord injury developed in 6 patients (7.8%). At multivariable analysis, the distance of the distal aortic neck from the celiac trunk was the only independent predictor of postoperative spinal cord injury (odds ratio, 0.75; 95% confidence interval, 0.56-0.99; P=.046); open surgical repair of the abdominal aortic disease was associated with a higher risk of spinal cord injury but did not reach statistical significance (odds ratio, 0.16; 95% confidence interval, 0.02-1.06; P=.057). Actuarial survival estimates at 1, 2, and 5 years after the procedure were 80%±5%, 68%±6%, and 63%±7%, respectively. Spinal cord injury did not impair survival (P=.885). In our experience, the risk of spinal cord injury is still substantial at 8% in patients with multilevel aortic disease. The distance of the distal landing zone from the celiac trunk is a significant predictor of spinal cord ischemia. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  7. Overexpression of Catalase in Vascular Smooth Muscle Cells Prevents the Formation of Abdominal Aortic Aneurysms

    Science.gov (United States)

    Parastatidis, Ioannis; Weiss, Daiana; Joseph, Giji; Taylor, W Robert

    2013-01-01

    Objective Elevated levels of oxidative stress have been reported in abdominal aortic aneurysms (AAA), but which reactive oxygen species (ROS) promotes the development of AAA remains unclear. Here we investigate the effect of the hydrogen peroxide (H2O2) degrading enzyme catalase on the formation of AAA. Approach and Results AAA were induced with the application of calcium chloride (CaCl2) on mouse infrarenal aortas. The administration of PEG-catalase, but not saline, attenuated the loss of tunica media and protected against AAA formation (0.91±0.1 mm vs. 0.76±0.09 mm). Similarly, in a transgenic mouse model, catalase over-expression in the vascular smooth muscle cells (VSMC) preserved the thickness of tunica media and inhibited aortic dilatation by 50% (0.85±0.14 mm vs. 0.57±0.08 mm). Further studies showed that injury with CaCl2 decreased catalase expression and activity in the aortic wall. Pharmacologic administration or genetic over-expression of catalase restored catalase activity and subsequently decreased matrix metalloproteinase activity. In addition, a profound reduction in inflammatory markers and VSMC apoptosis was evident in aortas of catalase over-expressing mice. Interestingly, as opposed to infusion of PEG-catalase, chronic over-expression of catalase in VSMC did not alter the total aortic H2O2 levels. Conclusions The data suggest that a reduction in aortic wall catalase activity can predispose to AAA formation. Restoration of catalase activity in the vascular wall enhances aortic VSMC survival and prevents AAA formation primarily through modulation of matrix metalloproteinase activity. PMID:23950141

  8. Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome: Midterm outcomes and aortic remodeling.

    Science.gov (United States)

    Faure, Elsa Madeleine; El Batti, Salma; Abou Rjeili, Marwan; Ben Abdallah, Iannis; Julia, Pierre; Alsac, Jean-Marc

    2018-05-17

    The study objective was to assess the midterm outcomes and aortic remodeling in patients with Marfan syndrome with complicated acute type B aortic dissection treated with stent-assisted, balloon-induced intimal disruption and relamination. We reviewed all patients treated with stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection associated with Marfan syndrome according to the revised Ghent criteria. Between 2015 and November 2017, 7 patients with Marfan syndrome underwent stent-assisted, balloon-induced intimal disruption and relamination for a complicated acute type B aortic dissection. The median age of patients was 47 years (range, 23-70). Four patients had a history of aortic root replacement. Technical success was achieved in 100%. Three patients required an adjunctive procedure for renal artery stenting (n = 2) and iliac artery stenting (n = 1). There was no in-hospital death, 30-day postoperative stroke, spinal cord ischemia, ischemic colitis, or renal failure requiring dialysis. At a median follow-up of 15 months (range, 7-28), 1 patient required aortic arch replacement for aneurysmal degeneration associated with a type Ia endoleak at 2 years, giving a late reintervention rate of 14%. There was no other secondary endoleak. The primary visceral patency rate was 100%. There were no all-cause deaths reported. At last computed tomography scan, all patients had complete aortic remodeling of the treated thoracoabdominal aorta. Distally, at the nonstented infrarenal aortoiliac level, 6 patients had persistent false lumen flow with stable aorto-iliac diameter in 5. One patient had iliac diameter growth (27 mm diameter at last computed tomography scan). Stent-assisted, balloon-induced intimal disruption and relamination of aortic dissection in patients with Marfan syndrome is feasible, safe, and associated with an immediate and midterm persisting thoracoabdominal aortic remodeling. Copyright

  9. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  10. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z. [Dept. of Imaging and Applied Physics, Curtin Univ. of Tech., Perth, WA (Australia); Allen, Y.; Fitzsimmons, B.; Hartely, D. [Cook R and D, WA (Australia); Lawrence-Brown, M. [Dept. of Public Health, Curtin Univ. of Tech., Perth, WA (Australia)

    2007-06-15

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  11. Efficacy of collagen silver-coated polyester and rifampin-soaked vascular grafts to resist infection from MRSA and Escherichia coli in a dog model.

    Science.gov (United States)

    Schneider, Fabrice; O'Connor, Stephen; Becquemin, Jean Pierre

    2008-11-01

    The primary objective of this study was to compare the efficacy of a collagen silver-coated polyester graft, InterGard, with a gelatin-sealed graft, Gelsoft, both soaked in rifampin, for resistance to direct bacterial contamination in an animal model. The second objective was to confirm the lack of inflammation from silver acetate. Vascular grafts, 6 mm in diameter, were implanted in the infrarenal aorta of 28 dogs. Intravenous cefamandole (20 mg/kg) was injected intraoperatively in all dogs. The dogs were divided into three groups. Group I included 12 dogs. Six dogs received silver grafts and six dogs received gelatin-sealed grafts, all soaked with rifampin. Grafts implanted in group I were directly infected with methicillin-resistant Staphylococcus aureus (MRSA). Group II included also six silver grafts and six gelatin-sealed grafts, all soaked with rifampin. Dogs of group II were directly infected with Escherichia coli. Group III comprised four dogs, which received gelatin unsealed grafts, directly infected with MRSA, the control group. All dogs were followed by regular clinical examination, including blood cultures. Grafts in groups I and III and in group II were harvested at 30 days and 10 days, respectively. Bacterial analyses were performed on the explanted grafts. Histology was performed on both the tissue samples and the anastomotic sites of the harvested grafts. In group I, no grafts were infected with MRSA, irrespective of graft type. In group II, no silver grafts were infected with E. coli, whereas one (16.6%) of six gelatin-sealed grafts was infected (p = 0.317). In group III, three (75%) of the four grafts were infected with MRSA. The infection rate in the silver grafts and the gelatin-sealed grafts soaked in rifampin in group I compared with the unsealed gelatin grafts in group III was statistically significantly different (p anastomoses in three (25%) gelsoft grafts of 12 in groups I and II. There were no clinical or biological signs of inflammation

  12. Current role of endovascular therapy in Marfan patients with previous aortic surgery

    Directory of Open Access Journals (Sweden)

    Ibrahim Akin

    2008-02-01

    Full Text Available Ibrahim Akin, Stephan Kische, Tim C Rehders, Tushar Chatterjee, Henrik Schneider, Thomas Körber, Christoph A Nienaber, Hüseyin InceDepartment of Medicine, Division of Cardiology at the University Hospital Rostock, Rostock School of Medicine, Ernst-Heydemann-Str. 6, 18057 Rostock, GermanyAbstract: The Marfan syndrome is a heritable disorder of the connective tissue which affects the cardiovascular, ocular, and skeletal system. The cardiovascular manifestation with aortic root dilatation, aortic valve regurgitation, and aortic dissection has a prevalence of 60% to 90% and determines the premature death of these patients. Thirty-four percent of the patients with Marfan syndrome will have serious cardiovascular complications requiring surgery in the first 10 years after diagnosis. Before aortic surgery became available, the majority of the patients died by the age of 32 years. Introduction in the aortic surgery techniques caused an increase of the 10 year survival rate up to 97%. The purpose of this article is to give an overview about the feasibility and outcome of stent-graft placement in the descending thoracic aorta in Marfan patients with previous aortic surgery.Keywords: Marfan syndrome, aortic dissection, root replacement, stent-graft, previous aortic surgery

  13. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  14. Epidemiology of aortic disease - aneurysm, dissection, occlusion

    International Nuclear Information System (INIS)

    Steckmeier, B.

    2001-01-01

    The physiological infrarenal aortic diameter varies between 12.4 mm in women an 27.6 mm in men. As defined, an aneurysmatic dilatation begins with 29 mm. According to that, 9% of all people above the age of 65 are affected by an abdominal aortic aneurysm (AAA). Compared with the female sex, the male sex predominates at a rate of about 5:1. The disease is predominant in men of the white race. In black men, black and white women the incidence of AAA is identical. 38 to 50 percent of the AAA patients (patients) suffer from hypertension, 33 to 60% from coronary, 28% from cerebrovascular and 25% from peripheral occlusive disease. The AAA expansion rate varies between 0.2 and 0.8 cm per year and is exponential from a diameter of 5 cm on. In autopsy studies, the rupture rates with AAA diameters of 7 cm were below 5%, 39% and 65%, respecitvely. 70% of the AAA patients do not die of a rupture, but of a cardiac disease. Serum markers, such as metalloproteinases and procollagen peptides are significantly increased in AAA patients. Thoraco-abdominal aneurysms (TAA) make up only 2 to 5% of all degenerative aneurysms. 20 to 30% of the TAA patients are also affected by an AAA. 80% of the TAA are degenerative, 15 to 20% are a consequence of the chronic dissection - including 5% of Marfan patients -, 2% occur in case of infections and 1 to 2% in case of aortitis. The TAA incidence in 100,000 person-years is 5.9% during a monitoring period of 30 years. In case of TAA, an operation is indicated with a maximum diameter of 5.5 to 6 cm and more and, in case of a Marfan's syndrome (incidence of 1:10,000), with a maximum diameter of 5.5 cm and more. With regard to aorto-iliac occlusive diseases, there are defined 3 types of distribution. Type I refers to the region of the bifurcation itself. Type II defines the diffuse aortoiliac spread of the disease. Type III designates multiple-level occlusions also beyond the inguinal ligament. Type I patients in most cases are female and more

  15. Reoperative aortic root replacement: Outcome in a contemporary series.

    Science.gov (United States)

    Esaki, Jiro; Leshnower, Bradley G; Binongo, Jose N; Lasanajak, Yi; McPherson, LaRonica; Thourani, Vinod H; Chen, Edward P

    2017-09-01

    Reoperative aortic root replacement is a challenging procedure associated with significant mortality and morbidity. The purpose of this study was to investigate the outcomes of reoperative aortic root replacement when performed in a number of complex clinical settings and to identify risk factors for operative mortality and long-term survival. From 2006 to 2015, 280 consecutive patients at an academic center underwent reoperative aortic root replacement after a variety of previous aortic or cardiac operations. Logistic regression and extended Cox proportional hazards regression analyses were used to determine risk factors for operative mortality and long-term survival, respectively. The mean age of patients was 52.5 ± 14.1 years. Prior operations included proximal aortic replacement in 113 patients, valve surgery in 162 patients, and coronary artery bypass grafting in 46 patients. Concomitant procedures included arch replacement in 135 patients, coronary artery bypass grafting in 68 patients, and mitral valve repair/replacement in 18 patients. Operative mortality was 14.3%. Five-year survival was 74.0%. Univariable analysis did not find previous root replacement, prior proximal aortic surgery, and concomitant arch replacement to be risk factors for operative mortality. In the multivariable analysis, chronic lung disease, prior myocardial infarction, and concomitant mitral valve surgery were risk factors for operative mortality. Age, peripheral artery disease, emergency, and concomitant mitral valve surgery were risk factors for mortality in the late phase. Reoperative aortic root replacement represents complex procedures carrying significant morbidity and mortality. Chronic lung disease, prior myocardial infarction, and concomitant mitral valve surgery were risk factors for operative mortality. Age, peripheral artery disease, emergency, and concomitant mitral valve surgery were risk factors for long-term mortality. Copyright © 2017 The American Association for

  16. Early Results of Chimney Technique for Type B Aortic Dissections Extending to the Aortic Arch

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chen [Affiliated Hospital of Nantong University, Department of General Surgery (China); Tang, Hanfei; Qiao, Tong; Liu, Changjian; Zhou, Min, E-mail: 813477618@qq.com [The Affiliated Hospital of Nanjing University Medical School, Department of Vascular Surgery, Nanjing Drum Tower Hospital (China)

    2016-01-15

    ObjectiveTo summarize our early experience gained from the chimney technique for type B aortic dissection (TBAD) extending to the aortic arch and to evaluate the aortic remodeling in the follow-up period.MethodsFrom September 2011 to July 2014, 27 consecutive TBAD patients without adequate proximal landing zones were retrograde analyzed. Chimney stent-grafts were deployed parallel to the main endografts to reserve flow to branch vessels while extending the landing zones. In the follow-up period, aortic remodeling was observed with computed tomography angiography.ResultsThe technical success rate was 100 %, and endografts were deployed in zone 0 (n = 3, 11.1 %), zone 1 (n = 18, 66.7 %), and zone 2 (n = 6, 22.2 %). Immediately, proximal endoleaks were detected in 5 patients (18.5 %). During a mean follow-up period of 17.6 months, computed tomography angiography showed all the aortic stent-grafts and chimney grafts to be patent. Favorable remodeling was observed at the level of maximum descending aorta and left subclavian artery with expansion of true lumen (from 18.4 ± 4.8 to 25 ± 0.86 mm, p < 0.001 and 27.1 ± 0.62 to 28.5 ± 0.37 mm, p < 0.001) and depressurization of false lumen (from 23.7 ± 2.7 to 8.7 ± 3.8 mm, p < 0.001, from 5.3 ± 1.2 to 2.1 ± 2.1 mm, p < 0.001). While at the level of maximum abdominal aorta, suboptimal remodeling of the total aorta (from 24.1 ± 0.4 to 23.6 ± 1.5 mm, p = 0.06) and true lumen (from 13.8 ± 0.6 to 14.5 ± 0.4 mm, p = 0.08) was observed.ConclusionBased on our limited experience, the chimney technique with thoracic endovascular repair is demonstrated to be promising for TBAD extending to the arch with favorable aortic remodeling.

  17. Aortic arch malformations

    Energy Technology Data Exchange (ETDEWEB)

    Kellenberger, Christian J. [University Children' s Hospital, Department of Diagnostic Imaging, Zuerich (Switzerland)

    2010-06-15

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  18. Imaging in aortic dissection

    International Nuclear Information System (INIS)

    Yu-Qing Liu, M.D.

    1995-01-01

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.)

  19. Aortic arch malformations

    International Nuclear Information System (INIS)

    Kellenberger, Christian J.

    2010-01-01

    Although anomalies of the aortic arch and its branches are relatively uncommon malformations, they are often associated with congenital heart disease. Isolated lesions may be clinically significant when the airways are compromised by a vascular ring. In this article, the development and imaging appearance of the aortic arch system and its various malformations are reviewed. (orig.)

  20. Imaging in aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Yu-Qing Liu, M D [Chinese Academy of Medical Sciences, Beijing, BJ (China). Dept. of Radiology, Fu Wai Hospital and Cardiovascular Inst.

    1996-12-31

    Aortic dissection (AD) is a catastrophic aortic disease. Imaging techniques play an invaluable role in the diagnostic evaluation and management of patients with AD. Major signs of AD with different imaging modalities are described in this article with a pertinent discussion on guidelines for the optimized approach of imaging study (13 refs.).

  1. Calcification of a Synthetic Renovascular Graft in a Child

    Directory of Open Access Journals (Sweden)

    D.S.T. Chong

    Full Text Available : Introduction: Vascular grafts, especially in paediatric cases, need to be durable. Common failures such as thrombosis are well documented with research efforts directed towards them. However, there are lesser known causes of graft failure, such as graft calcification, and these also require further research focus. Report: A paediatric case is described in which a synthetic renovascular graft, implanted for mid-aortic syndrome, became calcified, necessitating surgical intervention to resolve graft malfunction. Significant calcification in the limb of a bifurcated polyethylene terephthalate graft was found to be the cause of resistant stenosis and refractory hypertension. Histology conducted on the explanted limb showed the presence of multinuclear giant cells, indicating a chronic foreign body response. Discussion: Calcification of vascular grafts is probably more common than previously recognised. Stenosis typically resistant to angioplasty may result in the long term and thus leading to surgical intervention. In young children, this is suboptimal as these grafts need to last throughout adulthood. Explanted prosthetic grafts should be sent to specialist registries such as that in Strasbourg to be optimally assessed so that contributory factors can be identified. Keywords: Renovascular graft, Paediatric, Calcification

  2. Outcomes of fenestrated and branched endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms.

    Science.gov (United States)

    Schanzer, Andres; Simons, Jessica P; Flahive, Julie; Durgin, Jonathan; Aiello, Francesco A; Doucet, Danielle; Steppacher, Robert; Messina, Louis M

    2017-09-01

    More than 80% of infrarenal aortic aneurysms are treated by endovascular repair. However, adoption of fenestrated and branched endovascular repair for complex aortic aneurysms has been limited, despite high morbidity and mortality associated with open repair. There are few published reports of consecutive outcomes, inclusive of all fenestrated and branched endovascular repairs, starting from the inception of a complex aortic aneurysm program. Therefore, we examined a single center's consecutive experience of fenestrated and branched endovascular repair of complex aortic aneurysms. This is a single-center, prospective, observational cohort study evaluating 30-day and 1-year outcomes in all consecutive patients who underwent fenestrated and branched endovascular repair of complex aortic aneurysms (definition: requiring one or more fenestrations or branches). Data were collected prospectively through an Institutional Review Board-approved registry and a physician-sponsored investigational device exemption clinical trial (G130210). We performed 100 consecutive complex endovascular aortic aneurysm repairs (November 2010 to March 2016) using 58 (58%) commercially manufactured custom-made devices and 42 (42%) physician-modified devices to treat 4 (4%) common iliac, 42 (42%) juxtarenal, 18 (18%) pararenal, and 36 (36%) thoracoabdominal aneurysms (type I, n = 1; type II, n = 4; type III, n = 12; type IV, n = 18; arch, n = 1). The repairs included 309 fenestrations, branches, and scallops (average of 3.1 branch arteries/case). All patients had 30-day follow-up for 30-day event rates: three (3%) deaths; six (6%) target artery occlusions; five (5%) progressions to dialysis; eight (8%) access complications; one (1%) paraparesis; one (1%) bowel ischemia; and no instances of myocardial infarction, paralysis, or stroke. Of 10 type I or type III endoleaks, 8 resolved (7 with secondary intervention, 1 without intervention). Mean follow-up time was 563 days (interquartile range

  3. Intravascular stent graft with polyurethane and metallic stent: experimental study

    International Nuclear Information System (INIS)

    Do, Young Soo; Lee, Won Jae; Kim, Boo Kyung Han; Park, Jae Hyung; Lee, Hak Jong; Lee, Sang Hyun; Kim, Sung Hyun; Kim, Jong Won; Ha, Jongwon

    1997-01-01

    To evaluate the usefulness of a new model of the stent graft, and of tissue response related to placement of the stent graft. The stent graft was constructed from polyurethane (Pellethane) graft and Hanaro stent(12mm in diameter, 45mm in length, 10 bends). A stent grafts was inserted into the lower thoracic aorta in each of six adult mongrel dogs(body weight, 12-16kg). At one, two, four, and six months, follow-up studies of angiography and spiral CT angiography were preformed to evaluate wascular patency, vascular stenosis, and thrombus formation. Two dogs were sacrificed at 1month, 2months, and 6months after insertion of the stent graft and macroscopic, light microscopic, and scanning electron microscopic examinations of the aortic segment including the stent graft were performed to evaluate intimal hyperplasia, endothelial growth to the graft, and thrombus formation. During follow-up at one, two, four, and six months, angiography or spiral CT angiography showed 20-100% luminal stenosis or occlusion of the lower thoracic aorta by the thrombus and perigraft leaks in three dogs(50%), and collateral vessels caused by occlusion of the aorta in two (33.3%). On gross examination, there were thrombi of 1-5mm thickness at the graft portions in all dogs, and this thickness gradually increased. The mean thickness of intimal hyperplasia at the stent portion gradually increased from 120μm to 227μm and the mean thickness of intimal hyperplasia at the graft portion from 93μm to 914μm. This thickness was greater at the graft portion than at the stent portion. Scanning electron microscopy showed elliptical endothelial lining on the neointimal surfaces at each end of the graft. Thrombi caused stenosis or occlusion of the stent graft. In order for such a graft to be ideal, further study is needed

  4. CArbon dioxide surgical field flooding and aortic NO-touch off-pump coronary artery bypass grafting to reduce Neurological injuries after surgical coronary revascularisation (CANON): protocol for a randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms

    Science.gov (United States)

    Szwed, Krzysztof; Pawliszak, Wojciech; Serafin, Zbigniew; Kowalewski, Mariusz; Tomczyk, Remigiusz; Perlinski, Damian; Szwed, Magdalena; Tomaszewska, Marta; Anisimowicz, Lech; Borkowska, Alina

    2017-01-01

    Introduction Neurological injuries remain a major concern following coronary artery bypass grafting (CABG) that offsets survival benefit of CABG over percutaneous coronary interventions. Among numerous efforts to combat this issue is the development of off-pump CABG (OPCABG) that obviates the need for extracorporeal circulation and is associated with improved neurological outcomes. The objective of this study is to examine whether the neuroprotective effect of OPCABG can be further pronounced by the use of two state-of-the-art operating techniques. Methods and analysis In this randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms, a total of 360 patients will be recruited. They will be allocated in a 1:1:1 ratio to two treatment arms and one control arm. Treatment arms undergoing either aortic no-touch OPCABG or OPCABG with partial clamp applying carbon dioxide surgical field flooding will be compared against control arm undergoing OPCABG with partial clamp. The primary endpoint will be the appearance of new lesions on control brain MRI 3 days after surgery. Secondary endpoints will include the prevalence of new focal neurological deficits in the first 7 days after surgery, the occurrence of postoperative cognitive dysfunction at either 1 week or 3 months after surgery and the incidence of delirium in the first 7 days after surgery. Data will be analysed on intention-to-treat principles and a per protocol basis. Ethics and dissemination Ethical approval has been granted for this study. Results will be disseminated through peer-reviewed media. Trial registration number NCT03074604; Pre-results. Date and version identifier 10-Mar-2017 Original PMID:28698347

  5. CArbon dioxide surgical field flooding and aortic NO-touch off-pump coronary artery bypass grafting to reduce Neurological injuries after surgical coronary revascularisation (CANON): protocol for a randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms.

    Science.gov (United States)

    Krzysztof, Szwed; Wojciech, Pawliszak; Zbigniew, Serafin; Mariusz, Kowalewski; Remigiusz, Tomczyk; Damian, Perlinski; Magdalena, Szwed; Marta, Tomaszewska; Lech, Anisimowicz; Alina, Borkowska

    2017-07-10

    Neurological injuries remain a major concern following coronary artery bypass grafting (CABG) that offsets survival benefit of CABG over percutaneous coronary interventions. Among numerous efforts to combat this issue is the development of off-pump CABG (OPCABG) that obviates the need for extracorporeal circulation and is associated with improved neurological outcomes. The objective of this study is to examine whether the neuroprotective effect of OPCABG can be further pronounced by the use of two state-of-the-art operating techniques. In this randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms, a total of 360 patients will be recruited. They will be allocated in a 1:1:1 ratio to two treatment arms and one control arm. Treatment arms undergoing either aortic no-touch OPCABG or OPCABG with partial clamp applying carbon dioxide surgical field flooding will be compared against control arm undergoing OPCABG with partial clamp. The primary endpoint will be the appearance of new lesions on control brain MRI 3 days after surgery. Secondary endpoints will include the prevalence of new focal neurological deficits in the first 7 days after surgery, the occurrence of postoperative cognitive dysfunction at either 1 week or 3 months after surgery and the incidence of delirium in the first 7 days after surgery. Data will be analysed on intention-to-treat principles and a per protocol basis. Ethical approval has been granted for this study. Results will be disseminated through peer-reviewed media. NCT03074604; Pre-results. 10-Mar-2017 Original. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Bovine aortic arch with supravalvular aortic stenosis.

    Science.gov (United States)

    Idhrees, Mohammed; Cherian, Vijay Thomas; Menon, Sabarinath; Mathew, Thomas; Dharan, Baiju S; Jayakumar, K

    2016-09-01

    A 5-year-old boy was diagnosed to have supravalvular aortic stenosis (SVAS). On evaluation of CT angiogram, there was associated bovine aortic arch (BAA). Association of BAA with SVAS has not been previously reported in literature, and to best of our knowledge, this is the first case report of SVAS with BAA. Recent studies show BAA as a marker for aortopathy. SVAS is also an arteriopathy. In light of this, SVAS can also possibly be a manifestation of aortopathy associated with BAA. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  7. Bovine aortic arch with supravalvular aortic stenosis

    Directory of Open Access Journals (Sweden)

    Mohammed Idhrees

    2016-09-01

    Full Text Available A 5-year-old boy was diagnosed to have supravalvular aortic stenosis (SVAS. On evaluation of CT angiogram, there was associated bovine aortic arch (BAA. Association of BAA with SVAS has not been previously reported in literature, and to best of our knowledge, this is the first case report of SVAS with BAA. Recent studies show BAA as a marker for aortopathy. SVAS is also an arteriopathy. In light of this, SVAS can also possibly be a manifestation of aortopathy associated with BAA.

  8. Bone Graft Alternatives

    Science.gov (United States)

    ... Spine Treatment Spondylolisthesis BLOG FIND A SPECIALIST Treatments Bone Graft Alternatives Patient Education Committee Patient Education Committee ... procedure such as spinal fusion. What Types of Bone Grafts are There? Bone grafts that are transplanted ...

  9. [Change of paradigms in the surgical treatment of complex thoracic aortic disease].

    Science.gov (United States)

    Herold, Ulf; Tsagakis, Konstantinos; Kamler, Markus; Massoudy, Parwis; Assenmacher, Eva; Eggebrecht, Holger; Buck, Thomas; Jakob, Heinz

    2006-08-01

    One of the main issues in complex thoracic aortic disease, requiring the replacement of the ascending aorta, the entire aortic arch and the descending aorta, is the vast amount of surgery necessary to cure the patient. Though one-stage repair is feasible by a clamshell thoracotomy, the associated surgical trauma and perioperative morbidity limit this approach to younger patients only. Classic surgical repair consist of a two-stage strategy, whereby, in the first step, the ascending aorta and the aortic arch are replaced via a midline sternotomy. In the second step, via a lateral thoracotomy, the descending aorta is replaced. The two stages may sum up to a mortality of 20%; furthermore, the waiting period between the stages is associated with a mortality rate of 10% of its own. Additionally, the two-stage strategy has an inherent limitation, due to the comorbidity and advanced age of the majority of patients. Therefore, the second stage cannot be offered to up to 30% of patients. New developments and improvements in aortic surgery were introduced to overcome these shortcomings and to simplify the surgical repair. The "elephant trunk" principle, introduced by Borst et al. in 1983, was an important step to facilitate surgical repair, but still required the second step. With the introduction of endovascular repair of thoracic aortic disease with stent grafts implanted retrograde via the femoral artery, new therapeutic concepts emerged. In the late 1990s, two Japanese groups reported first trials to stabilize the free-floating "elephant trunk" prosthesis by implantation of nitinol stent grafts into the vascular graft. The applied devices were purely custom-made and nonstandardized. The availability of industrially made and CE-marked stent-graft devices raised the possibility to apply them in open aortic arch surgery. The experience with stent-graft devices implanted antegrade into the descending aorta (Medtronic Talent) was reported first by the Essen and the Vienna

  10. [Valve-sparing Replacement in Patients with Aortic Root Dilatation].

    Science.gov (United States)

    Yamazaki, Kazuhiro; Minatoya, Kenji; Ueda, Ryoma; Takehara, Masato; Sakamoto, Kazuhisa; Ide, Yujiro; Kanemitsu, Hideo; Ueyama, Koji; Ikeda, Tadashi

    2018-01-01

    Valve-sparing root replacement is increasingly used to overcome drawbacks associated with valvular prostheses. In our institution, 7 patients underwent valve-sparing root replacement from August 2016 to July 2017. The mean age was 45 years (range, 14~69 years). Three patients had Marfan syndrome and 1 had Loeys-Dietz syndrome with acute aortic dissection. All patients underwent surgery with reimplantation technique using a Valsalva graft. Two patients required repair of aortic valve leaflet prolapse. All patients had an excellent clinical course, with mild or no aortic regurgitation and a decrease in end-diastolic volume on echocardiography. These results support the continued use of valve-sparing root replacement in selected patients.

  11. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    International Nuclear Information System (INIS)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha

    2016-01-01

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  12. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha, E-mail: alex_cantador@yahoo.com.br [Universidade Estadual de Campinas (FCM/UNICAMP), Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2016-07-15

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  13. Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: a case report.

    Science.gov (United States)

    Nakahira, Junko; Ishii, Hisanari; Sawai, Toshiyuki; Minami, Toshiaki

    2015-03-07

    Fibrin glue is used commonly during cardiac surgery but can behave as an intracardiac abnormal foreign body following surgery. There have been few such cases reported, and they were typically noticed only because of the resulting catastrophic cardiac conditions, such as valvular malfunction. We report a case where, for the first time, transesophageal echocardiography was used to detected fibrin glue that was adherent to the ventricular side of a patient's aortic valve immediately after aortic declamping. A 45-year-old Japanese man with Marfan syndrome underwent an aortic valve-sparing operation to treat moderate aortic valve regurgitation resulting from enlargement of his right coronary cusp. Fibrin glue was lightly applied to the suture line between the previous and new grafts. Transesophageal echocardiography performed prior to weaning from the cardiopulmonary bypass revealed mild aortic valve regurgitation in addition to a mobile membranous structure attached to the ventricular side of his aortic valve. It was identified as fibrin glue. We resolved the regurgitation by removing the fibrin glue and repeating the aortic cusp plication. The patient had no complications during recovery. Fibrin glue can act as an intracardiac foreign body and lead to a potentially fatal embolism. We demonstrated the use of transesophageal echocardiography to detect a fibrin glue-derived intracardiac abnormal foreign body and to confirm its removal. To the best of our knowledge, this is the first case where fibrin glue adherent to the aortic valve was detected by transesophageal echocardiography. These findings demonstrate the importance of using transesophageal echocardiography during cardiac surgery that involves using biological glues.

  14. Type A aortic dissection in Marfan syndrome: extent of initial surgery determines long-term outcome.

    Science.gov (United States)

    Rylski, Bartosz; Bavaria, Joseph E; Beyersdorf, Friedhelm; Branchetti, Emanuela; Desai, Nimesh D; Milewski, Rita K; Szeto, Wilson Y; Vallabhajosyula, Prashanth; Siepe, Matthias; Kari, Fabian A

    2014-04-01

    Data on outcomes after Stanford type A aortic dissection in patients with Marfan syndrome are limited. We investigated the primary surgery and long-term results in patients with Marfan syndrome who suffered aortic dissection. Among 1324 consecutive patients with aortic dissection type A, 74 with Marfan syndrome (58% men; median age, 37 years [first and third quartiles, 29 and 48 years]) underwent surgical repair (85% acute dissections; 68% DeBakey I; 55% composite valved graft, 30% supracoronary ascending replacement, 15% valve-sparing aortic root replacement; 12% total arch replacement; 3% in-hospital mortality) at 2 tertiary centers in the United States and Europe over the past 25 years. The rate of aortic reintervention with resternotomy was 24% (18 of 74) and of descending aorta (thoracic+abdominal) intervention was 30% (22 of 74) at a median follow-up of 8.4 years (first and third quartiles, 2.2 and 12.7 years). Freedom from need for aortic root reoperation in patients who underwent primarily a composite valved graft or valve-sparing aortic root replacement procedure was 95±3%, 88±5%, and 79±5% and in patients who underwent supracoronary ascending replacement was 83±9%, 60±13%, 20±16% at 5, 10, and 20 years. Secondary aortic arch surgery was necessary only in patients with initial hemi-arch replacement. Emergency surgery for type A dissection in patients with Marfan syndrome is associated with low in-hospital mortality. Failure to extend the primary surgery to aortic root or arch repair leads to a highly complex clinical course. Aortic root replacement or repair is highly recommended because supracoronary ascending replacement is associated with a high need (>40%) for root reintervention.

  15. Retrograde type A dissection following hybrid supra-aortic endovascular surgery in high-risk patients unfit for conventional open repair.

    Science.gov (United States)

    Yip, Hon C; Chan, Yiu C; Qing, Kai X; Cheng, Stephen W

    2018-04-01

    Hybrid procedures with combined open extra-anatomical supra-aortic bypasses and endovascular surgery are less invasive for patients with complex aortic arch pathology. The aim of this paper is to report patients who developed retrograde type A aortic dissection following initially successful hybrid endovascular treatment. Retrospective review of prospectively collected computerized departmental database. All patients with supra-aortic hybrid endovascular surgery and post-procedure retrograde type A dissection were identified. Patient demographics, comorbid conditions, perioperative parameters, procedural details and post-operative complications were collected. From May 2005 to July 2014, 163 patients underwent thoracic aortic endovascular procedures at our institution. From the 46 patients who had supra-aortic hybrid endovascular repair, six patients (6/46, 13% of all supra-aortic hybrid cases, 3 males) developed retrograde type A aortic dissection. All were elective cases, with 3 chronic dissecting aneurysms and 3 atherosclerotic aneurysms. All had one-stage hybrid procedures: 2 patients had carotid-carotid bypass grafts, one had carotid-carotid-left subclavian bypass graft, and 3 had bypass grafts from ascending aorta to innominate artery and left carotid artery. Five patients had Cook Zenith thoracic stent-grafts (Cook Medical, Bloomington, IN, USA), and one had Medtronic Valiant stent-grafts (Medtronic Vascular Inc, Santa Rosa, CA, USA). The retrograde type A dissection occurred with sudden symptoms at day 5, 6, 10, 20, 105 and 128, respectively. There were 3 immediate fatalities and 2 patients treated conservatively deemed unfit for reintervention (one died of pneumonia at 9 months, and one remained alive at 7 months post-complication). One patient underwent successful emergency open surgery and survived. Supra-aortic hybrid procedures in treating aortic arch pathology may be at risk of developing retrograde type A dissection. This post-operative complication

  16. Supra-aortic interventions for endovascular exclusion of the entire aortic arch.

    Science.gov (United States)

    Andrási, Terézia B; Grossmann, Marius; Zenker, Dieter; Danner, Bernhard C; Schöndube, Friedrich A

    2017-07-01

    Our aim was to analyze the outcomes of endovascular exclusion of the entire aortic arch (proximal landing in zone 0, distal landing in zone III or beyond, after Ishimaru) in which complete surgical debranching of the supra-aortic vessels (I), endovascular supra-aortic revascularization (chimney, fenestrated, or branched grafts) with partial surgical debranching (II), or total endovascular supra-aortic revascularization (III) was additionally performed. Publications describing endovascular repair of the aortic arch (2000-2016) were systematically searched and reviewed. From a total of 53 relevant studies including 1853 patients, only 1021 patients undergoing 35 different total aortic arch procedures were found eligible for further evaluation and included in group I, II, or III (429, 190, and 402 patients, respectively). Overall early mortality was higher in group I vs groups II and III (P = .001; 1 - β = 95.6%) but exceeded in group III (18.6%) and group II (14.0%) vs group I (8.0%; P = .044; 1 - β = 57.4%) for diseases involving zone 0. Mortality was higher in all subgroups treated for zone 0 disease compared with corresponding subgroups treated for zone I to zone III disease. The incidence of cerebral ischemic events was increased in groups I and II vs group III (7.5% and 11% vs 1.7%; P = .0001) and correlated with early mortality (R 2  = .20; P = .033). The incidence of type II endoleaks and endovascular reintervention was similar between groups and correlated with each other (R 2  = .37; P = .004). Type Ia endoleak occurred more often in groups II and III than in group I (7.1% and 12.1% vs 5.8%; P = .023) and correlated with midterm mortality (R 2  = .53; P = .005). Retrograde type A dissection was low in all groups, whereas aneurysm growth was higher in group III (2.6%, 4.2%, 10.7%; P = .002), correlating with midterm mortality (R 2  = .311; P = .009). Surgical revision slightly correlated with surgical complications (R 2  = .18; P = .044

  17. Uptake of radiolabeled leukocytes in prosthetic graft infection

    International Nuclear Information System (INIS)

    Serota, A.I.; Williams, R.A.; Rose, J.G.; Wilson, S.E.

    1981-01-01

    The utility of radionuclide labeled leukocytes in the demonstration of infection within vascular prostheses was examined. The infrarenal aorta was replaced with a 3 cm Dacron graft in 12 dogs. On the third postoperative day, six of the animals received an intravenous injection of 10(8) Staphylococcus aureus. Labeled leukocyte scans were performed at postoperative days one and three, and then weekly for 8 weeks with indium-111 and technetium-99 labeled autologous leukocytes. When scans showed focal uptake of isotope in the area of prosthetic material, the grafts were aseptically excised and cultured on mannitol-salt agar. Both control and infected animals had retroperitoneal isotope activity in the immediate postoperative period that disappeared by the end of the first week. By the eighth postoperative week, all of the animals that received the bacteremic challenge had both radionuclide concentration in the region of the vascular prosthesis and S. aureus cultured subsequently from the perigraft tissues. None of the control animals had either radionuclide or bacteriologic evidence of infection at the eighth postoperative week. The radiolabeled leukocyte scan is a highly sensitive and specific technique, clinically applicable for the diagnosis of vascular prosthetic infections

  18. Flow and wall shear stress characterization following endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model

    NARCIS (Netherlands)

    Boersen, Johannes T.; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H.; Ku, David N.; de Vries, Jean-Paul P.M.; Reijnen, Michel M.P.J.

    2017-01-01

    Background Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is

  19. Long-Term Follow-Up After Endovascular Treatment of Acute Aortic Emergencies

    International Nuclear Information System (INIS)

    Pitton, M. B.; Herber, S.; Schmiedt, W.; Neufang, A.; Dorweiler, B.; Dueber, C.

    2008-01-01

    Purpose. To investigate the long-term outcome and efficacy of emergency treatment of acute aortic diseases with endovascular stent-grafts. Methods. From September 1995 to April 2007, 37 patients (21 men, 16 women; age 53.9 ± 19.2 years, range 18-85 years) with acute complications of diseases of the descending thoracic aorta were treated by endovascular stent-grafts: traumatic aortic ruptures (n = 9), aortobronchial fistulas due to penetrating ulcer or hematothorax (n = 6), acute type B dissections with aortic wall hematoma, penetration, or ischemia (n = 13), and symptomatic aneurysm of the thoracic aorta (n = 9) with pain, penetration, or rupture. Diagnosis was confirmed by contrast-enhanced CT. Multiplanar reformations were used for measurement of the landing zones of the stent-grafts. Stent-grafts were inserted via femoral or iliac cut-down. Two procedures required aortofemoral bypass grafting prior to stent-grafting due to extensive arteriosclerotic stenosis of the iliac arteries. In this case the bypass graft was used for introduction of the stent-graft. Results. A total of 46 stent-grafts were implanted: Vanguard/Stentor (n = 4), Talent (n = 31), and Valiant (n = 11). Stent-graft extension was necessary in 7 cases. In 3 cases primary graft extension was done during the initial procedure (in 1 case due to distal migration of the graft during stent release, in 2 cases due to the total length of the aortic aneurysm). In 4 cases secondary graft extensions were performed-for new aortic ulcers at the proximal stent struts (after 5 days) and distal to the graft (after 8 months) and recurrent aortobronchial fistulas 5 months and 9 years after the initial procedure-resulting in a total of 41 endovascular procedures. The 30-day mortality rate was 8% (3 of 37) and the overall follow-up was 29.9 ± 36.6 months (range 0-139 months). All patients with traumatic ruptures demonstrated an immediate sealing of bleeding. Patients with aortobronchial fistulas also demonstrated a

  20. Inhibition of early AAA formation by aortic intraluminal pentagalloyl glucose (PGG) infusion in a novel porcine AAA model

    DEFF Research Database (Denmark)

    Kloster, Brian O; Lund, Lars; Lindholt, Jes S

    2016-01-01

    to prevent or delay their expansion. In this study, we investigated whether intraluminal delivered pentagalloyl glucose (PGG) can impair the early AAA development in a porcine model. METHODS: The infrarenal aorta was exposed in thirty pigs. Twenty underwent an elastase based AAA inducing procedure and ten...... of these received an additional intraluminal PGG infusion. The final 10 were sham operated and served as controls. RESULTS: All pigs who only had an elastase infusion developed macroscopically expanding AAAs. In pigs treated with an additional PGG infusion the growth rate of the AP-diameter rapidly returned...... and histology. CONCLUSION: In our model, intraluminal delivered PGG is able to penetrate the aortic wall from the inside and impair the early AAA development by stabilizing the elastic lamellae and preserving their integrity. The principle holds a high clinical potential if it can be translated to human...

  1. Aortic valve replacement for aortic stenosis caused by alkaptonuria.

    Science.gov (United States)

    Hiroyoshi, Junko; Saito, Aya; Panthee, Nirmal; Imai, Yasushi; Kawashima, Dai; Motomura, Noboru; Ono, Minoru

    2013-03-01

    We report a case of aortic stenosis associated with ochronosis in a 70-year-old man who underwent biologic aortic valve replacement. Intraoperative findings included ochronosis of a severely calcified pigmented aortic valve along with pigmentation of the intima of the aorta. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Rasche, Volker [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, University of Ulm, Department of Internal Medicine II, Ulm (Germany); Oberhuber, Alexander; Orend, Karl-Heinz [University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Trumpp, Stephan [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Bornstedt, Axel; Merkle, Nico; Rottbauer, Wolfgang [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); Hoffmann, Martin [University Hospital Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany)

    2011-07-15

    To evaluate the feasibility of MRI for static and dynamic assessment of the deployment of thoracic aortic stent grafts after emergency implantation in trauma patients. Twenty patients initially presenting with a rupture of the thoracic aorta were enrolled in this study. All patients underwent thoracic endovascular aortic repair (TEVAR). The deployment of the implanted stent graft was assessed by CTA and MRI, comprising the assessment of the aortic arch with and without contrast agent, and the assessment of the motion of the stent graft over the cardiac cycle. The stent graft geometry and motion over the cardiac cycle were assessable by MRI in all patients. Flow-mediated signal variations in areas of flow acceleration could be well visualised. No statistically significant differences in stent-graft diameters were observed between CT and MRI measurements. MRI appears to be a valuable tool for the assessment of thoracic stent grafts. It shows similar performance in the accurate assessment of stent-graft dimensions to the current gold standard CTA. Its capability of providing additional functional information and the lack of ionising radiation and nephrotoxic contrast agents may make MRI a valuable tool for monitoring patients after TEVAR. (orig.)

  3. Bone grafting: An overview

    Directory of Open Access Journals (Sweden)

    D. O. Joshi

    2010-08-01

    Full Text Available Bone grafting is the process by which bone is transferred from a source (donor to site (recipient. Due to trauma from accidents by speedy vehicles, falling down from height or gunshot injury particularly in human being, acquired or developmental diseases like rickets, congenital defects like abnormal bone development, wearing out because of age and overuse; lead to bone loss and to replace the loss we need the bone grafting. Osteogenesis, osteoinduction, osteoconduction, mechanical supports are the four basic mechanisms of bone graft. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. An ideal bone graft material is biologically inert, source of osteogenic, act as a mechanical support, readily available, easily adaptable in terms of size, shape, length and replaced by the host bone. Except blood, bone is grafted with greater frequency. Bone graft indicated for variety of orthopedic abnormalities, comminuted fractures, delayed unions, non-unions, arthrodesis and osteomyelitis. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. By adopting different procedure of graft preservation its antigenicity can be minimized. The concept of bone banking for obtaining bone grafts and implants is very useful for clinical application. Absolute stability require for successful incorporation. Ideal bone graft must possess osteogenic, osteoinductive and osteocon-ductive properties. Cancellous bone graft is superior to cortical bone graft. Usually autologous cancellous bone graft are used as fresh grafts where as allografts are employed as an alloimplant. None of the available type of bone grafts possesses all these properties therefore, a single type of graft cannot be recomm-ended for all types of orthopedic abnormalities. Bone grafts and implants can be selected as per clinical problems, the equipments available and preference of

  4. Pathogenetic Basis of Aortopathy and Aortic Valve Disease

    Science.gov (United States)

    2018-02-19

    Aortopathies; Thoracic Aortic Aneurysm; Aortic Valve Disease; Thoracic Aortic Disease; Thoracic Aortic Dissection; Thoracic Aortic Rupture; Ascending Aortic Disease; Descending Aortic Disease; Ascending Aortic Aneurysm; Descending Aortic Aneurysm; Marfan Syndrome; Loeys-Dietz Syndrome; Ehlers-Danlos Syndrome; Shprintzen-Goldberg Syndrome; Turner Syndrome; PHACE Syndrome; Autosomal Recessive Cutis Laxa; Congenital Contractural Arachnodactyly; Arterial Tortuosity Syndrome

  5. Can postoperative mean transprosthetic pressure gradient predict survival after aortic valve replacement?

    NARCIS (Netherlands)

    Koene, Bart M.; Hamad, Mohamed A. Soliman; Bouma, Wobbe; Mariani, Massimo A.; Peels, Kathinka C.; van Dantzig, Jan-Melle; van Straten, Albert H.

    In this study, we sought to determine the effect of the mean transprosthetic pressure gradient (TPG), measured at 6 weeks after aortic valve replacement (AVR) or AVR with coronary artery bypass grafting (CABG) on late all-cause mortality. Between January 1998 and March 2012, 2,276 patients (mean age

  6. Impact of prosthesis-patient mismatch on early and late mortality after aortic valve replacement

    NARCIS (Netherlands)

    Koene, Bart M.; Hamad, Mohamed A. Soliman; Bouma, Wobbe; Mariani, Massimo A.; Peels, Kathinka C.; van Dantzig, Jan-Melle; van Straten, Albert H.

    2013-01-01

    Background: The influence of prosthesis-patient mismatch (PPM) on survival after aortic valve replacement (AVR) remains controversial. In this study, we sought to determine the effect of PPM on early (30 days) after AVR or AVR combined with coronary artery bypass grafting (AVR with CABG). Methods:

  7. 78 FR 36702 - Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems (IABP) for...

    Science.gov (United States)

    2013-06-19

    .... FDA-2013-N-0581] Cardiovascular Devices; Reclassification of Intra-Aortic Balloon and Control Systems... Device In the preamble to the proposed rule (44 FR 13369; March 9, 1979), the Cardiovascular Device... Bypass Grafting: A Propensity Score Analysis,'' Interactive Cardiovascular and Thoracic Surgery, vol. 9...

  8. Aortic root repair for thoracic aorta false aneurysm following Bentall procedure.

    Science.gov (United States)

    Kumar, Sanjay; Jones, Steve; Sivananthan, U M; McGoldrick, J P

    2008-08-01

    The Bentall procedure for aortic root replacement in Marfan's syndrome is safe and durable. We describe successful repair of periprosthetic valvular leak, 12 years following Bentall repair with composite graft. The aim of this report is to analyse and evaluate technical factors leading to this unusual occurrence.

  9. Traumatic partial avulsion of a single right subclavian artery from the aortic arch and definitive repair.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Sears-Rogan, Pamela; Young, Richard S; Kanda, Louis T; Ellis, Jennifer L

    2006-01-01

    Blunt injury to the right subclavian artery is a rare complication of severe deceleration trauma often associated with significant morbidity and mortality. We describe an atypical presentation in a patient who sustained a traumatic avulsion of his right subclavian artery arising off the aortic arch. An interposition graft was used to restore the continuity of the artery to the ascending thoracic aorta.

  10. Endovascular abdominal aortic aneurysm repair complicated by spondylodiscitis and iliaco-enteral fistula.

    Science.gov (United States)

    de Koning, Heleen D; van Sterkenburg, Steven M M; Pierie, Maurice E N; Reijnen, Michel M P J

    2008-06-01

    Infections of abdominal aortic endografts are rare. There are no reports on the association with spondylodiscitis. We report a case of a 74-year-old man who underwent endovascular aneurysm repair (EVAR) and subsequently femorofemoral bypass placement due to occlusion of the right limb of the endograft. Six months later, he presented with rectal bleeding, weight loss, back pain, and low abdominal pain. Computed tomography revealed extensive abscess formation with air in and around the endograft and psoas muscles, in continuity with destructive spondylodiscitis L3-4. There was a small bowel loop in close proximity to the occluded right leg of the endograft, which was filled with air bubbles. An axillofemoral bypass was created followed by a laparotomy. Intra-operatively, an iliaco-enteral fistula was found. The small bowel defect was sutured, the endograft completely removed, and the infrarenal aorta and both common iliac arteries were closed. Necrotic fragments of the former L3-4 disk were removed. The postoperative course was uneventful. Seven months postoperatively, the patient had recovered well. Iliaco-enteric fistula and spondylodiscitis are rare complications of aortic aneurysm repair. This is the first report of spondylodiscitis after EVAR.

  11. Functional renal perfusion imaging with colour mapping: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)?

    International Nuclear Information System (INIS)

    Blomley, Martin J.K.; McBride, Alan; Mohammedtagi, Sima; Albrecht, Thomas; Harvey, Christopher J.; Jaeger, Rolf; Standfield, Nigel J.; Dawson, Peter

    1999-01-01

    Aim: To ensure optimal timing with pre-operative spiral CT for abdominal aortic aneurysms (AAA), an initial 'timing' single level CT is commonly performed with a small bolus of contrast. This can be exploited to obtain adjunct functional information on renal perfusion. We have investigated the potential of this to measure renal perfusion, to produce colour renal perfusion maps and to predict surgical outcome in infrarenal aortic aneurysm assessment. Methods: We studied 21 patients being assessed for repair of infrarenal AAA. Prior to the spiral CT, a single level through the renal hili and aorta was scanned after the intravenous injection of 25 ml of contrast given at 10 ml/s. Ten 1 s duration scans were performed from 8 to 30 s after injection. Optimal timing for CT angiography can then be determined. Time-density curves were then drawn for both kidneys and aorta using regions of interest (ROIs) or pixel-by-pixel analysis. Renal cortical perfusion was measured using both ROI analysis and pseudocolour perfusion images. Following previous work, perfusion was calculated as the peak upslope of the tissue time density curve divided by peak aortic enhancement. Results: Cortical mean perfusion averaged 2.48 ml/min per ml (range 0.8-3.7 ml/min per ml n=34) and the values obtained agreed with literature expectations. Follow up in the 10 patients proceeding to AAA repair suggest low mean perfusion values and predict a raised postoperative creatinine (P<0.05) Conclusions: Additional functional data and imaging can be obtained from the initial timing scan of a CT study, without requiring a dedicated study

  12. Robotic aortic surgery.

    Science.gov (United States)

    Duran, Cassidy; Kashef, Elika; El-Sayed, Hosam F; Bismuth, Jean

    2011-01-01

    Surgical robotics was first utilized to facilitate neurosurgical biopsies in 1985, and it has since found application in orthopedics, urology, gynecology, and cardiothoracic, general, and vascular surgery. Surgical assistance systems provide intelligent, versatile tools that augment the physician's ability to treat patients by eliminating hand tremor and enabling dexterous operation inside the patient's body. Surgical robotics systems have enabled surgeons to treat otherwise untreatable conditions while also reducing morbidity and error rates, shortening operative times, reducing radiation exposure, and improving overall workflow. These capabilities have begun to be realized in two important realms of aortic vascular surgery, namely, flexible robotics for exclusion of complex aortic aneurysms using branched endografts, and robot-assisted laparoscopic aortic surgery for occlusive and aneurysmal disease.

  13. Endograft Collapse After Endovascular Treatment for Thoracic Aortic Disease

    International Nuclear Information System (INIS)

    Bandorski, Dirk; Brueck, Martin; Guenther, Hans-Ulrich; Manke, Christoph

    2010-01-01

    Endovascular treatment is an established therapy for thoracic aortic disease. Collapse of the endograft is a potentially fatal complication. We reviewed 16 patients with a thoracic endograft between 2001 and 2006. Medical records of the treated patients were studied. Data collected include age, gender, diagnosis, indication for endoluminal treatment, type of endograft, and time of follow up. All patients (n = 16; mean age, 61 years; range, 21-82 years) underwent computed tomography (CT) for location of the lesion and planning of the intervention. Time of follow-up with CT scan ranged from 1 to 61 months. Indications for endovascular treatment were degenerative aneurysm (n = 7; 44%), aortic dissection (n = 2; 12%), perforated aortic ulcer (n = 4; 25%), and traumatic aortic injury (n = 3; 19%). Three patients suffered from a collapse of the endograft (one patient distal, two patients proximal) between 3 and 8 days after endovascular treatment. These patients were younger (mean age, 37 ± 25 years vs. 67 ± 16 years; P 0.05]; distal, 45 ± 23.5% vs. 38 ± 21.7% [P > 0.05]). Proximal collapse was corrected by placing a bare stent. In conclusion, risk factors for stent-graft collapse are a small lumen of the aorta and a small radius of the aortic arch curvature (young patients), as well as oversizing, which is an important risk factor and is described for different types of endografts and protheses (Gore TAG and Cook Zenith). Dilatation of the collapsed stent-graft is not sufficient. Following therapy implantation of a second stent or surgery is necessary in patients with a proximal endograft collapse. Distal endograft collapse can possibly be treated conservatively under close follow-up.

  14. Contemporary economic and clinical evaluations of endovascular repair for intact descending thoracic aortic aneurysms.

    Science.gov (United States)

    Silingardi, Roberto; Gennai, Stefano; Coppi, Giovanni; Chester, Johanna; Marcheselli, Luigi; Brunetti, Massimo

    2017-12-01

    The aim of this study was to assess clinical and contemporary costs associated with elective endovascular repair of intact descending thoracic aortic aneurysms (DTAA) into the mid-term follow-up. A retrospective review of a prospectively maintained clinical database including 29 consecutive patients from July 2005 to December 2009 treated with elective endovascular repair (TEVAR) or TEVAR and surgical infrarenal repair (hybrid) of intact DTAA was performed. Mean age was 74.5 years old (±7.1). Primary clinical endpoints include mortality and major morbidity. Additionally a comprehensive economic appraisal of individual in-hospital and follow-up costs was executed. Economic endpoints include in-hospital and follow-up costs and patient discharge status. Elective endovascular and open repairs' clinical and economical outcomes in contemporary literature were assessed for comparison according to PRISMA standards. Immediate mortality was 6.9% (1/24 TEVAR and 1/5 hybrid). Three respiratory complications were recorded (11%; 2 TEVAR, 1 hybrid). Renal and cardiac complication rates were 7.4% (1 TEVAR, 1 hybrid) and 3.7% (1 TEVAR) respectively. Routine discharge home was achieved for 85% of patients (95.7% TEVAR, 25% hybrid). Three endoleaks were treated throughout the follow-up (2 TEVAR, 1 hybrid; mean 30.4 mo, ±19.9) rendering an 11% (3/27) reintervention rate. Average immediate cost was €21,976.87 for elective endovascular repair and €33,783.21 for elective endovascular hybrid repair. Additional reintervention and routine follow-up costs augmented immediate costs by 12.4%. This study supports satisfying immediate clinical outcomes for TEVAR and TEVAR+surgical infrarenal procedures. Although limited by a small population size and difficulties in economic comparisons, this study presents the real world social and economic cost scenario for both elective TEVAR and TEVAR hybrid treatment of DTAA of both the in-hospital and at mid term follow-up periods.

  15. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    mortality were collected. Group analysis by patient geographic distribution and by annular diameter of the prosthesis utilized was conducted. Patients with a manufacturer's labeled prosthesis size > or = 21 mm were assigned to the 'large' aortic size subset, while those with a prosthesis size ... differences in the distribution of either gender or BSA. In the multivariable model, south European patients were seven times more likely to receive a smaller-sized aortic valve (OR = 6.5, 95% CI = 4.82-8.83, p

  16. Assessment of Competence in EVAR Stent Graft Sizing and Selection

    DEFF Research Database (Denmark)

    Strøm, M; Lönn, L.; Bech, B.

    2017-01-01

    Objectives and background: The aims of this study were to develop a test of competence in endovascular aortic repair (EVAR) stent graft sizing and selection; to examine the test for evidence of validity; and to explore the experience required for the task. Methods: The test was developed based...... measurements, Mann-Whitney U test could discriminate between experts and novices (p = .002), between experts and intermediates (p = .010), and between novices and intermediates (p = .036). In stent selection the experts performed significantly better than both the novices and the intermediates (p = .002 and p...... of competence in vessel analysis and stent graft selection for endovascular aortic repair. This was supported by strong validity evidence with good internal consistency and discriminatory ability. The tool may be used to facilitate training and certification of future endovascular specialists....

  17. Endoluminal Treatment of Ruptured Abdominal Aortic Aneurysm with Small Intestinal Submucosa Sandwich Endografts: A Pilot Study in Sheep

    International Nuclear Information System (INIS)

    Yamada, Katsuyuki; Pavcnik, Dusan; Uchida, Barry T.; Timmermans, Hans A.; Corless, Christopher L.; Yin, Qiang; Yamakado, Koichiro; Wha Park, Joong; Roesch, Josef; Keller, Frederick S.; Sato, Morio; Yamada, Ryusaku

    2001-01-01

    Purpose: To evaluate efficacy of small intestinal submucosa (SIS) Sandwich endografts for the treatment of acute rupture of abdominal aortic aneurysms (AAA) and to explore the short-term reaction of the aorta to this material.Methods: In eight adult sheep, an infrarenal AAA was created transluminally by dilation of a short Palmaz stent. In six sheep, the aneurysm was then ruptured by overdilation of the stent with a large angioplasty balloon. Two sheep with AAAs that were not ruptured served as controls. A SIS Sandwich endograft, consisting of a Z stent frame with 5 bodies and covered inside and out with SIS, was used to exclude the ruptured and non-ruptured AAAs. Follow-up aortography was done immediately after the procedure and before sacrifice at 4, 8, or 12 weeks. Autopsy and histologic studies followed.Results: Endograft placement was successful in all eight sheep. Both ruptured and non-ruptured AAAs were successfully excluded. Three animals with AAA rupture developed hind leg paralysis due to compromise of the arterial supply to the lower spinal cord and were sacrificed 1 day after the procedure. In five animals, three with rupture and two controls, follow-up aortograms revealed no aortic stenoses and no perigraft leaks. Gross and histologic studies revealed incorporation of the endografts into the aortic wall with replacement of SIS by dense neointima that was completely endothelialized in areas where the endograft was in direct contact with the aortic wall. In central portions of the endograft, in contact with the thrombosed aneurysm, endothelialization was incomplete even at 12 weeks.Conclusion: The SIS Sandwich endografts effectively excluded simple AAAs and ruptured AAAs. They were rapidly incorporated into the aortic wall. A detailed long-term study is warranted

  18. The impact of aortic manipulation on neurologic outcomes after coronary artery bypass surgery: a risk-adjusted study.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Stamou, Sotiris C; Dullum, Mercedes K C; Hill, Peter C; Haile, Elizabeth; Boyce, Steven W; Bafi, Ammar S; Petro, Kathleen R; Corso, Paul J

    2004-11-01

    Cerebral embolization of atherosclerotic plaque debris caused by aortic manipulation during conventional coronary artery bypass grafting (CABG) is a major mechanism of postoperative cerebrovascular accidents (CVA). Off-pump CABG (OPCABG) reduces stroke rates by minimizing aortic manipulation. Consequently, the effect of different levels of aortic manipulation on neurologic outcomes after CABG surgery was examined. From January 1998 to June 2002, 7,272 patients underwent isolated CABG surgery through three levels of aortic manipulation: full plus tangential (side-biting) aortic clamp application (on-pump surgery; n = 4,269), only tangential aortic clamp application (OPCABG surgery; n = 2,527) or an "aortic no-touch" technique (OPCABG surgery; n = 476). A risk-adjusted logistic regression analysis was performed to establish the likelihood of postoperative stroke with each technique. Preoperative risk factors for stroke from the literature, and those found significant in a univariable model were used. A significant association for postoperative stroke correspondingly increasing with the extent of aortic manipulation was demonstrated by the univariable analysis (CVA incidence respectively increasing from 0.8% to 1.6% to a maximum of 2.2%, p < 0.01). In the logistic regression model, patients who had a full and a tangential aortic clamp applied were 1.8 times more likely to have a stroke versus those without any aortic manipulation (95% confidence interval: 1.15 to 2.74, p < 0.01) and 1.7 times more likely to develop a postoperative stroke than those with only a tangential aortic clamp applied (95% confidence interval: 1.11 to 2.48, p < 0.01). Aortic manipulation during CABG is a contributing mechanism for postoperative stroke. The incidence of postoperative stroke increases with increased levels of aortic manipulation.

  19. Prosthetic vascular graft infection through a median sternotomy: a multicentre review †.

    Science.gov (United States)

    Oda, Tatsuya; Minatoya, Kenji; Kobayashi, Junjiro; Okita, Yutaka; Akashi, Hidetoshi; Tanaka, Hiroyuki; Kawaharada, Nobuyoshi; Saiki, Yoshikatsu; Kuniyoshi, Yukio; Nishimura, Kunihiro

    2015-06-01

    The aim of this study is to analyse the treatment outcomes of thoracic prosthetic graft infection. A retrospective chart review was conducted at six hospitals and included the records of 68 patients treated for postoperative prosthetic vascular graft infection (mean age: 62.3 ± 15.1, male 51) from January 2000 to December 2013. The number of patients and the locations of the treated infections were as follows: 13 for aortic root, 16 for ascending aorta, 35 for aortic arch and 4 for aortic root to arch. In-hospital infection occurred in 43 patients and after discharge in 25. The mean follow-up time was 2.0 ± 2.3 years. The follow-up rate was 94.1%. The most commonly isolated micro-organism was Staphylococcus aureus (72.1%). Rereplacement of infectious graft was performed in 18 patients (Dacron graft in 12, homograft in 4 and rifampicin-bonded Dacron graft in 2). The overall hospital mortality rate was 35.3% (24/68). The mortality rate among the patients with graft rereplacement was 33.3% (6/18), with pedicled muscle flaps or pedicled omental flaps to cover the graft 25.9% (7/27), with irrigation 55.0% (11/20) and on antibiotic therapy only 0% (0/3). Our multivariate analysis demonstrated that the risk factors of hospital death increased in the absence of pedicled flaps (muscle or omentum) to cover the graft (P = 0.001), age over 55 (P = 0.003), time from onset of initial operation prosthetic vascular graft infection have not been satisfactory. However, the use of pedicled muscle or omental flaps to cover the graft could improve the outcomes. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  20. Grafting and curing

    International Nuclear Information System (INIS)

    Garnett, J.L.; Loo-Teck Ng; Visay Viengkhou

    1998-01-01

    Progress in radiation grafting and curing is briefly reviewed. The two processes are shown to be mechanistically related. The parameters influencing yields are examined particularly for grafting. For ionising radiation grafting systems (EB and gamma ray) these include solvents, substrate and monomer structure, dose and dose-rate, temperature and more recently role of additives. In addition, for UV grafting, the significance of photoinitiators is discussed. Current applications of radiation grafting and curing are outlined. The recent development of photoinitiator free grafting and curing is examined as well as the potential for the new excimer laser sources. The future application of both grafting and curing is considered, especially the significance of the occurrence of concurrent grafting during cure and its relevance in environmental considerations

  1. Skin graft - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100100.htm Skin graft - series—Normal anatomy To use the sharing features ... entire body, and acts as a protective barrier. Skin grafts may be recommended for: Extensive wounds Burns Specific ...

  2. Double aortic arch

    Science.gov (United States)

    Surgery can be done to fix double aortic arch. The surgeon ties off the smaller branch and separates it from the larger branch. Then the surgeon closes the ends of the aorta with stitches. This relieves pressure on the esophagus and windpipe.

  3. Bicuspid aortic valve

    Science.gov (United States)

    ... aortic disease. In: Otto CM, Bonow RO, eds. Valvular Heart Disease: A Companion to Braunwald’s Heart Disease . 4th ed. ... PA: Elsevier Saunders; 2014:chap 13. Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman’s Cecil ...

  4. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  5. Valve-sparing aortic root replacement in Marfan syndrome.

    Science.gov (United States)

    Cameron, Duke E; Vricella, Luca A

    2005-01-01

    Marfan syndrome is the most common inherited connective tissue disorder, affecting approximately 1 in 10,000 live births. The cardinal features of Marfan syndrome are the abnormalities of the skeleton (tall stature, arachnodactyly, and joint hyperelasticity), eye (lens subluxation), and aorta (root aneurysm with proclivity toward rupture and dissection). Aortic catastrophe accounts for most of the premature mortality among Marfan patients, a risk that climbs steeply during adolescence and results in death of half of Marfan patients by the age of 40 years. Most of the improvement in life expectancy that has been achieved in Marfan syndrome is attributable to early recognition of aortic root aneurysms and prophylactic replacement with composite grafts (mechanical valve prostheses within Dacron conduits) before rupture or dissection occurs. Despite the excellent early and late results with composite grafts, there has been growing interest in operative procedures that replace the sinuses but preserve the aortic valve leaflets, to avoid anticoagulation and minimize the risk of prosthesis-related endocarditis. These procedures are still in evolution and late results are not yet known, but as with mitral repair in the setting of myxomatous disease, valve-sparing procedures in Marfan syndrome have weathered a storm of initial criticism and skepticism and are steadily gaining acceptance.

  6. Improving diagnostic accuracy in aortic prosthetic graft infection

    NARCIS (Netherlands)

    Saleem, Rani

    2017-01-01

    Vaatprothese infecties (VPI) komen relatief weinig voor, echter het klinisch beloop ervan kent hoge morbiditeit en mortaliteit. Derhalve worden bij de implantatie van vaatprotheses diverse preventieve maatregelen genomen om VPI te voorkomen. Ondanks preventieve maatregelen blijft prothesemateriaal

  7. An experimental and computational study of the inferior vena cava hemodynamics under respiratory-induced collapse of the infrarenal IVC.

    Science.gov (United States)

    Tedaldi, Elisabetta; Montanari, Chiara; Aycock, Kenneth I; Sturla, Francesco; Redaelli, Alberto; Manning, Keefe B

    2018-04-01

    the flow rate distribution between the right and left iliac veins induces significant variations in the flow characteristics. We speculate that asymmetries in the flow may generate unbalanced forces on the IVC wall and on placed IVC filters that could promote filter tilting and migration, although this requires further investigation. If unbalanced forces are present in vivo, the forces should be considered when determining the optimal placement positions and geometric features for IVC filters. Therefore, these findings motivate further investigation of the in vivo hemodynamics in the infrarenal IVC. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Bone grafts in dentistry

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar

    2013-01-01

    Full Text Available Bone grafts are used as a filler and scaffold to facilitate bone formation and promote wound healing. These grafts are bioresorbable and have no antigen-antibody reaction. These bone grafts act as a mineral reservoir which induces new bone formation.

  9. Valve-sparing aortic root reconstruction in children, teenagers, and young adults.

    Science.gov (United States)

    Tweddell, James S; Earing, Michael G; Bartz, Peter J; Dunham-Ingles, Jennifer L; Woods, Ronald K; Mitchell, Michael E

    2012-08-01

    We reviewed our experience with valve-sparing aortic root reconstruction (VSARR) using the sinus of Valsalva graft in children, teenagers, and young adults with connective tissue disorders. Results of a single-center experience with VSARR in children, teenagers, and young adults were retrospectively analyzed. End points were death, freedom from reintervention, and freedom from valve dysfunction. Between 2003 and 2010, 16 patients (Marfan, 9; Loeys Dietz syndrome, 6; conotruncal, 1) underwent VSARR. The mean age was 20±7.4 (range, 9 to 36 years). Indications for VSAAR were aortic root enlargement in 14 (sinus of Valsalva Z-score, 6.2±2) and aortic dissection in 2. Additional procedures included replacement of the ascending aorta in 7, with additional replacement of the aortic arch in 2. No early or late deaths occurred. One patient required a pacemaker. One patient with Loeys-Dietz syndrome required reoperation for aneurysmal dilatation of the coronary buttons. Two patients underwent replacement of the thoracoabdominal aorta for chronic dissection. Follow-up by echocardiography or magnetic resonance imaging at a mean of 33±29 months showed more than mild aortic regurgitation in 2 patients. Both patients with moderate aortic insufficiency also had a bicuspid aortic valve. VSARR using the sinus of Valsalva graft is a reproducible technique that achieves acceptable early and intermediate results. It is suitable for children, teenagers, and young adults. Anticoagulation is avoided. The procedure is appropriate for emergency operations but should be used with caution in patients with a bicuspid aortic valve. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

    Directory of Open Access Journals (Sweden)

    Samuel Jessula, MDCM

    2017-09-01

    Full Text Available We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, including endograft repositioning and endovascular stenting through the femoral and brachial approach. The patient eventually underwent open splenorenal bypass with a Y Gore-Tex graft (W. L. Gore & Associates, Flagstaff, Ariz. After 3 months, computed tomography showed no evidence of endoleak and patent renal arteries. Renal function was well maintained, and the patient did not require dialysis.

  11. Aortic valve-sparing operation in Marfan syndrome: what do we know after a decade?

    Science.gov (United States)

    Kallenbach, Klaus; Baraki, Hassina; Khaladj, Nawid; Kamiya, Hiroyuki; Hagl, Christian; Haverich, Axel; Karck, Matthias

    2007-02-01

    We assessed the outcome in patients with Marfan syndrome operated on exclusively with the aortic valve-sparing reimplantation technique for aortic root aneurysms during more than a decade. Between July 1993 and April 2005, the aortic valve-sparing reimplantation technique (David I) was used in 325 patients. In 59 patients with clinical evidence of Marfan syndrome, procedures were done for aortic root aneurysm (n = 55) or aortic dissection type A (n = 4). Their mean age was 30 +/- 12 years (range, 9 to 62 years), and 37 (63%) were male. Additional procedures were arch replacement in 4 patients, coronary artery bypass grafting in 1, mitral valve surgery in 9, and closure of atrial septal defect in 3. Mean follow-up was 54 +/- 37 months (range, 0 to 139 months). No patient died during the first 30 days postoperatively. Mean bypass time was 163 +/- 34 minutes (range, 99 to 248 minutes), and mean aortic cross clamp time was 126 +/- 28 minutes (range, 78 to 202 minutes). Four patients (6.8%) required rethoracotomy for postoperative bleeding. Five late deaths (8.5%) occurred during follow-up. Reoperation of the reconstructed valve was required in 7 patients. Freedom from reoperation was 88% +/- 5% at 5 years and 80% +/- 9% at 10 years. Mean grade of aortic insufficiency was 1.81 preoperatively compared with 0.20 early postoperatively (p valve should encourage use of this technique in patients with Marfan syndrome.

  12. Impact of Aortic Insufficiency on Ascending Aortic Dilatation and Adverse Aortic Events After Isolated Aortic Valve Replacement in Patients With a Bicuspid Aortic Valve.

    Science.gov (United States)

    Wang, Yongshi; Wu, Boting; Li, Jun; Dong, Lili; Wang, Chunsheng; Shu, Xianhong

    2016-05-01

    Aberrant flow pattern and congenital fragility bestows bicuspid aortic valve (BAV) with a propensity toward ascending aorta dilatation, aneurysm, and dissection. Whether isolated aortic valve replacement (AVR) can prevent further dilatation in BAV ascending aorta and what indicates concurrent aortic intervention in the case of valve operation remain controversial. From June 2006 to January 2009, patients with a BAV who underwent isolated AVR were consecutively included and categorized into aortic insufficiency (BAV-AI, n = 84) and aortic stenosis (n = 112) groups, and another population of patients with a tricuspid aortic valve with aortic insufficiency (n = 149) was also recruited during the same period for comparison of annual aortic dilatation rate and adverse aortic events after isolated AVR. With a median follow-up period of 72 months (interquartile range, 66 to 78 months), ascending aorta dilatation rates were faster in the BAV-AI group than the BAV plus aortic stenosis and tricuspid aortic valve with aortic insufficiency groups (both p regression analysis identified aortic insufficiency (hazard ratio, 3.7; 95% confidence interval, 1.2 to 11.1; p = 0.019) as an independent risk factor for adverse aortic events among patients with BAV in general, whereas preoperative ascending aortic diameter larger than 45 mm (hazard ratio, 13.8; 95% confidence interval, 3.0 to 63.3; p = 0.001) served as a prognostic indicator in the BAV-AI group. An aggressive policy of preventive aortic interventions seemed appropriate in patients with BAV-AI during AVR, and BAV phenotype presenting as either insufficiency or stenosis should be taken into consideration when contemplating optimal surgical strategies for BAV aortopathy. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Regression in left ventricular mass after aortic valve replacement for chronic aortic regurgitation is unrelated to prosthetic valve size.

    Science.gov (United States)

    Brown, Morgan L; Schaff, Hartzell V; Suri, Rakesh M; Li, Zhuo; Sundt, Thoralf M; Dearani, Joseph A; Enriquez-Sarano, Maurice

    2011-08-01

    We examined the role of prosthesis-patient mismatch on left ventricular mass regression after aortic valve replacement for chronic aortic valve regurgitation. We selected patients who had complete preoperative and follow-up echocardiograms with measurement of left ventricular mass. Patients were excluded who had moderate or greater aortic valve stenosis, concomitant coronary artery bypass grafting, or mitral valve procedures. Patients' mean age was 55 ± 17 years; 21% were female. The mean preoperative indexed left ventricular mass was 150 ± 45 g/m(2). Patients with mildly (n = 44; mean indexed mass, 126 ± 15 g/m(2)), moderately (n = 31; mean indexed mass, 168 ± 11 g/m(2)), or severely (n = 15; mean indexed mass, 241 ± 34 g/m(2)) increased preoperative indexed left ventricular mass, were similar, except for lower ejection fractions, larger end-diastolic dimensions, and larger ventricular wall thicknesses in the severely enlarged group (P regression was unrelated to labeled valve size, prosthesis-patient mismatch, or measured indexed effective aortic valve area. A greater preoperative indexed left ventricular mass (P regression. Despite having greater left ventricular mass regression, patients with severe preoperative indexed left ventricular mass did not return to normal values (mean, 142 ± 25 g/m(2)). Left ventricular mass regression after aortic valve replacement for chronic aortic regurgitation is unrelated to indexed prosthetic valve area. Although incomplete, regression is greatest in patients with the largest preoperative indexed left ventricular mass. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  14. Case report and review of the literature total endovascular repair of acute ascending aortic rupture: a case report and review of the literature.

    Science.gov (United States)

    McCallum, John C; Limmer, Karl K; Perricone, Anthony; Bandyk, Dennis; Kansal, Nikhil

    2013-07-01

    Thoracic aortic endografting has been successfully implemented to treat aneurysmal disease of the distal aortic arch and descending thoracic aorta. Although there are reports of ascending aortic endovascular interventions, the total endovascular repair of a ruptured ascending aorta secondary to a Type A dissection has not been described. We report the case of a 77-year-old patient who presented with a ruptured ascending aortic aneurysm secondary to degeneration of a Stanford type A aortic dissection. His surgical history was significant for orthotropic heart transplant 19 years prior. The dissection, aneurysm, and rupture occurred in the native aorta distal to the ascending aortic suture line. At presentation, he was hemodynamically unstable with a right hemothorax. We placed 3 Medtronic Talent Thoracic Stent Graft devices (Medtronic Inc, Minneapolis, MN) across the suture line in the ascending aorta, excluding the rupture. The patient survived and has been followed to 25 months.

  15. Epidemiology and contemporary management of abdominal aortic aneurysms.

    Science.gov (United States)

    Ullery, Brant W; Hallett, Richard L; Fleischmann, Dominik

    2018-05-01

    Abdominal aortic aneurysm (AAA) is most commonly defined as a maximal diameter of the abdominal aorta in excess of 3 cm in either anterior-posterior or transverse planes or, alternatively, as a focal dilation ≥ 1.5 times the diameter of the normal adjacent arterial segment. Risk factors for the development of AAA include age > 60, tobacco use, male gender, Caucasian race, and family history of AAA. Aneurysm growth and rupture risk appear to be associated with persistent tobacco use, female gender, and chronic pulmonary disease. The majority of AAAs are asymptomatic and detected incidentally on various imaging studies, including abdominal ultrasound, and computed tomographic angiography. Symptoms associated with AAA may include abdominal or back pain, thromboembolization, atheroembolization, aortic rupture, or development of an arteriovenous or aortoenteric fistula. The Screening Abdominal Aortic Aneurysms Efficiently (SAAAVE) Act provides coverage for a one-time screening abdominal ultrasound at age 65 for men who have smoked at least 100 cigarettes and women who have family history of AAA disease. Medical management is recommended for asymptomatic patients with AAAs  5 mm/6 months), or presence of a fusiform aneurysm with maximum diameter of 5.5 cm or greater. Intervention for AAA includes conventional open surgical repair and endovascular aortic stent graft repair.

  16. Magnesium and diltiazem relaxes phenylephrine-precontracted rat aortic rings

    Science.gov (United States)

    Dogan, Mustafa; Peker, Recep O.; Donmez, Soner; Gokalp, Osman

    2012-01-01

    Perioperative vasospasm during cardiovascular surgery is a challenging problem. Several vasodilator agents are frequently utilized for its prevention in surgical practice. Magnesium and diltiazem both have known potential vasorelaxant effects. We planned to compare the efficacy of diltiazem and magnesium in relieving phenylephrine-precontracted rat aortic rings. Ten young adult female Wistar albino rats weighing 230–260 g were used in this study. The aortic rings in the organ bath equilibrated and reached their baseline tension. Precontraction was induced by 0.001 mmol/l phenylephrine and cumulative concentration–relaxation curves were obtained by consecutively increasing the addition of either diltiazem (10−6-0.1 mmol/l) or magnesium (0.1–10 mmol/l). The mean maximal relaxation responses observed by diltiazem and magnesium on separate aortic rings were 90 ± 3 and 53 ± 2%, respectively. The calculated EC50 of diltiazem was 0.01035 mmol/l, whereas the EC50 of magnesium was 4.064 mmol/l (P < 0.05). Both magnesium and diltiazem produced vasorelaxation on phenylephrine-precontracted rat aortic rings in this study, but the potency of diltiazem regarding the EC50 value was significantly higher than that of magnesium. Magnesium could be a candidate together with diltiazem to inhibit vasospasm on arterial grafts during coronary bypass surgery. PMID:22523136

  17. Estudo da resposta tissular à endoprótese recoberta de jugular bovina em veia cava inferior de suínos Bovine jugular covered stent-graft implanted in swine inferior vena cava - a study of tissue response

    Directory of Open Access Journals (Sweden)

    Cristina Ribeiro Riguetti Pinto

    2006-06-01

    aortic stent-graft deployment (Florida, USA. Ten handmade stent-grafts were implanted in 10 swine inferior venae cavae. All animals were submitted to perioperative venography. At necropsy, 2 months later, the stent-grafts were removed en bloc and histopathologic analysis was undertaken, in order to analyze its patency, adherence to neighboring tissues and incorporation to the venous wall, as well as tissue response. RESULTS: All stent-grafts were patent and adherent to venous wall, but six presented with gross trabeculation and four had some degree of perivascular fibrosis at macroscopy. Three animals developed lymphocele, one in the retroperitoneal space and the others in the abdominal wall. At histopathology, we observed chronic inflammatory reaction with foreign body granulomatous response in all cases, with prevalence of the tunica media (80%. CONCLUSION: The model presented low thrombogenicity, which corroborates the efficacy of the chosen means of preservation and material. However, there was low compatibility, probably due to the immunological obstacle of xenografts and exaggerated tissue response of the venous territory.

  18. Volumetric Nephrogram Represents Renal Function and Complements Aortic Anatomic Severity Grade in Predicting EVAR Outcomes.

    Science.gov (United States)

    Balceniuk, Mark D; Trakimas, Lauren; Aghaie, Claudia; Mix, Doran; Rasheed, Khurram; Seaman, Matthew; Ellis, Jennifer; Glocker, Roan; Doyle, Adam; Stoner, Michael C

    2018-07-01

    Chronic kidney disease (CKD) is a predictor of poor outcomes for patients undergoing endovascular aortic aneurysm repair (EVAR). Anatomic severity grade (ASG) represents a quantitative mechanism for assessing anatomical suitability for endovascular aortic repair. Anatomic severity grade has been correlated with repair outcomes and resource utilization. The purpose of this study was to identify a novel renal perfusion metric as a way to assist ASG with predicting EVAR outcomes. Retrospective review of a prospectively maintained database identified elective infrarenal aortic aneurysm repair cases. Anatomic grading was undertaken by independent reviewers. Using volumetric software, kidney volume, and a novel measure of kidney functional volume, the volumetric nephrogram (VN) was recorded. Systematic evaluation of the relationship of kidney volume and VN to CKD and ASG was undertaken using linear regression and receiver-operator statistical tools. A total of 386 cases with patient and anatomic data were identified and graded. Mean age was 72.9 ± 0.4 years. Renal volume renal volume (AUC = .628; P ≤ .0001) and VN (AUC = .628; P ≤ .0001). Regression analysis demonstrated a strong, inverse relationship between ASG and VN ( R 2 = .95). These data demonstrate that VN is a strong predictor of CKD in a large database of patients undergoing elective aneurysm repair. We demonstrate an inverse relationship between renal function and ASG that has not been previously described in the literature. Additionally, we have shown that VN complements ASG as a model of overall cardiovascular health and atherosclerotic burden. Outcomes in patients with poor renal function may be related to anatomical issues in addition to well-described systemic ramifications.

  19. Magnetic Resonance angiography with bolus contrast agent in abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Di Cesare, E.; Cerone, G.; Giordano, A.V.; Marsili, L.; Barile, A.; Michelini, O.; Masciocchi, C.; Spartera, C.

    2000-01-01

    Purpose of this paper is to investigate the potentials of 3D breath-hold contrast-enhanced Magnetic Resonance Angiography (MRA) in the diagnosis, follow-up and treatment planning of abdominal aortic aneurysms. Twenty-four patients with infrarenal aortic aneurysm underwent MRA. It was used a 1.5 T unit (GE Horizon, Echospeed 8.2), a phased array surface coil and 3D Fast SPGR T1-weighted sequences acquired on the coronal plane during patient breath-hold and after contrast agent i.v. administration. A bolus-test was done before angiography to optimize imaging delay time. After 3D MRA a Fast-SPGR T1-weighted sequence was acquired on the axial plane. The 3D MRA source images were processed with the MIP algorithm. Qualitative and quantitative analyses were carried out. Helical CT was performed in 6 cases and DSA in 7 cases. Surgery was the reference standard in 15 patients. MRA depicted aneurysm thrombosis in 22 cases, carrefour involvement in 18 cases and iliac arteries involvement in 3 cases. Accessory renal arteries were shown in 4 cases; iliac artery stenosis was associated in 5 cases. There was agreement between MR and Helical CT and DSA findings: surgery confirmed MRA results in 15/15 cases. 3D contrast-enhanced MRA can be considered the method of choice in the follow-up and treatment planning of abdominal aortic aneurysms, because it provides both angiographic and tomographic images: this allows to obtain more information, noninvasively and without the use of ionizing radiations [it

  20. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?

    Science.gov (United States)

    Malina, M; Lindblad, B; Ivancev, K; Lindh, M; Malina, J; Brunkwall, J

    1998-11-01

    To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.

  1. Elephant trunk in a small-calibre true lumen for chronic aortic dissection: cause of haemolytic anaemia?

    Science.gov (United States)

    Araki, Haruna; Kitamura, Tadashi; Horai, Tetsuya; Shibata, Ko; Miyaji, Kagami

    2014-12-01

    The elephant trunk technique for aortic dissection is useful for reducing false lumen pressure; however, a folded vascular prosthesis inside the aorta can cause haemolysis. The purpose of this study was to investigate whether an elephant trunk in a small-calibre lumen can cause haemolysis. Inpatient and outpatient records were retrospectively reviewed. Two cases of haemolytic anaemia after aortic surgery using the elephant trunk technique were identified from 2011 to 2013. A 64-year-old man, who underwent graft replacement of the ascending aorta for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta and moderate aortic regurgitation. A two-stage surgery was scheduled. Total arch replacement with an elephant trunk in the true lumen and concomitant aortic valve replacement were performed. Postoperatively, he developed severe haemolytic anaemia because of the folded elephant trunk. The anaemia improved after the second surgery, including graft replacement of the descending aorta. Similarly, a 61-year-old man, who underwent total arch replacement for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta. Graft replacement of the descending aorta with an elephant trunk inserted into the true lumen was performed. The patient postoperatively developed haemolytic anaemia because of the folded elephant trunk, which improved after additional stent grafting into the elephant trunk. A folded elephant trunk in a small-calibre lumen can cause haemolysis. Therefore, inserting an elephant trunk in a small-calibre true lumen during surgery for chronic aortic dissection should be avoided. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch.

    Science.gov (United States)

    Millan-Iturbe, Oscar; Sawaya, Fadi J; Bieliauskas, Gintautas; Chow, Danny H F; De Backer, Ole; Søndergaard, Lars

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) has evolved from a novel technology to an established therapy for high/intermediate-risk patients with severe symptomatic aortic stenosis (AS). Although TAVR is used to treat bicuspid severe AS, the large randomized trials typically excluded bicuspid AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a "gothic aortic arch"; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled a sharply angulated aortic arch. This life-threatening complication was successfully treated by thoracic endovascular aortic repair. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  3. Delayed recurrent nerve paralysis following post-traumatic aortic pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Mesolella Massimo

    2016-01-01

    Full Text Available Blunt trauma to the neck or to the chest are increasingly observed in the emergency clinical practice. They usually follow motor vehicle accidents or may be work or sports related. A wide pattern of clinical presentation can be potentially encountered. We report the uncommon case of a patient who was referred to our observation presenting with hoarseness and disphagia. Twenty days before he had sustained a car accident with trauma to the chest, neck and the mandible. Laryngoscopy showed a left recurrent laryngeal nerve palsy. Further otolaryngo-logical examination showed no other abnormality. At CT and MR imaging a post-traumatic aortic pseudoaneurysm was revealed. The aortic pseudoaneurysm was consequently repaired by implantation of an endovascular stent graft under local anesthesia. The patient was discharged 10 days later. At 30-days follow-up laryngoscopy the left vocal cord palsy was completely resolved.

  4. Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair

    NARCIS (Netherlands)

    Koenrades, Maaike A.; Klein, Almar; Leferink, Anne M.; Slump, Cornelis H.; Geelkerken, Robert H.

    2018-01-01

    Purpose: To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Methods: Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort

  5. 3D Stereoscopic Visualization of Fenestrated Stent Grafts

    International Nuclear Information System (INIS)

    Sun Zhonghua; Squelch, Andrew; Bartlett, Andrew; Cunningham, Kylie; Lawrence-Brown, Michael

    2009-01-01

    The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

  6. Neonatal aortic stenosis.

    Science.gov (United States)

    Drury, Nigel E; Veldtman, Gruschen R; Benson, Lee N

    2005-09-01

    Neonatal aortic stenosis is a complex and heterogeneous condition, defined as left ventricular outflow tract obstruction at valvular level, presenting and often requiring treatment in the first month of life. Initial presentation may be catastrophic, necessitating hemodynamic, respiratory and metabolic resuscitation. Subsequent management is focused on maintaining systemic blood flow, either via a univentricular Norwood palliation or a biventricular route, in which the effective aortic valve area is increased by balloon dilation or surgical valvotomy. In infants with aortic annular hypoplasia but adequately sized left ventricle, the Ross-Konno procedure is also an attractive option. Outcomes after biventricular management have improved in recent years as a consequence of better patient selection, perioperative management and advances in catheter technology. Exciting new developments are likely to significantly modify the natural history of this disorder, including fetal intervention for the salvage of the hypoplastic left ventricle; 3D echocardiography providing better definition of valve morphology and aiding patient selection for a surgical or catheter-based intervention; and new transcutaneous approaches, such as duel beam echo, to perforate the valve.

  7. Surgical treatment and thoracic endovascular aortic repair in type A aortic dissection in a pregnant patient with Marfan syndrome.

    Science.gov (United States)

    Sterner, Doerthe; Probst, Chris; Mellert, Friedrich; Schiller, Wolfgang

    2014-07-01

    We report an acute aortic dissection type Stanford A extending down to both iliac arteries affecting a 32-year-old woman suspected to have Marfan syndrome during week 37 of pregnancy. In a multidisciplinary approach, and emergency Cesarean section was performed followed by an abdominal hysterectomy and a valve-sparing aortic root replacement using a reimplantation technique. The aorta was replaced up to the hemi arch. Because of the high suspicion of visceral ischemia as confirmed ex juvantibus, an endovascular stent graft was implanted. Molecular testing revealed a frameshift mutation and confirmed the diagnosis of Marfan syndrome. Both the patient and her healthy child underwent an uneventful recovery. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Aortic root replacement in 372 Marfan patients: evolution of operative repair over 30 years.

    Science.gov (United States)

    Cameron, Duke E; Alejo, Diane E; Patel, Nishant D; Nwakanma, Lois U; Weiss, Eric S; Vricella, Luca A; Dietz, Harry C; Spevak, Philip J; Williams, Jason A; Bethea, Brian T; Fitton, Torin P; Gott, Vincent L

    2009-05-01

    We reviewed the evolution of practice and late results of aortic root replacement (ARR) in Marfan syndrome patients at our institution. A retrospective clinical review of Marfan patients undergoing ARR at our institution was performed. Follow-up data were obtained from hospital and office records and from telephone contact with patients or their physicians. Between September 1976 and September 2006, 372 Marfan syndrome patients underwent ARR: 269 had a Bentall composite graft, 85 had valve-sparing ARR, 16 had ARR with homografts, and 2 had ARR with porcine xenografts. In the first 24 years of the study, 85% received a Bentall graft; during the last 8 years, 61% had a valve-sparing procedure. There was no operative or hospital mortality among the 327 patients who underwent elective repair; there were 2 deaths among the 45 patients (4.4%) who underwent emergent or urgent operative repair. There were 74 late deaths (70 Bentalls, 2 homograft, and 2 valve-sparing ARRs). The most frequent causes of late death were dissection or rupture of the residual aorta (10 of 74) and arrhythmia (9 of 74). Of the 85 patients who had a valve-sparing procedure, 40 had a David II remodeling operation; there was 1 late death in this group, and 5 patients required late aortic valve replacement for aortic insufficiency. A David I reimplantation procedure using the De Paulis Valsalva graft has been used exclusively since May 2002. All 44 patients in this last group have 0 to 1+ aortic insufficiency. Prophylactic surgical replacement of the ascending aorta in patients with Marfan syndrome has low operative risk and can prevent aortic catastrophe in most patients. Valve-sparing procedures, particularly using the reimplantation technique with the Valsalva graft, show promise but have not yet proven as durable as the Bentall.

  9. Configuration affects parallel stent grafting results.

    Science.gov (United States)

    Tanious, Adam; Wooster, Mathew; Armstrong, Paul A; Zwiebel, Bruce; Grundy, Shane; Back, Martin R; Shames, Murray L

    2018-05-01

    A number of adjunctive "off-the-shelf" procedures have been described to treat complex aortic diseases. Our goal was to evaluate parallel stent graft configurations and to determine an optimal formula for these procedures. This is a retrospective review of all patients at a single medical center treated with parallel stent grafts from January 2010 to September 2015. Outcomes were evaluated on the basis of parallel graft orientation, type, and main body device. Primary end points included parallel stent graft compromise and overall endovascular aneurysm repair (EVAR) compromise. There were 78 patients treated with a total of 144 parallel stents for a variety of pathologic processes. There was a significant correlation between main body oversizing and snorkel compromise (P = .0195) and overall procedural complication (P = .0019) but not with endoleak rates. Patients were organized into the following oversizing groups for further analysis: 0% to 10%, 10% to 20%, and >20%. Those oversized into the 0% to 10% group had the highest rate of overall EVAR complication (73%; P = .0003). There were no significant correlations between any one particular configuration and overall procedural complication. There was also no significant correlation between total number of parallel stents employed and overall complication. Composite EVAR configuration had no significant correlation with individual snorkel compromise, endoleak, or overall EVAR or procedural complication. The configuration most prone to individual snorkel compromise and overall EVAR complication was a four-stent configuration with two stents in an antegrade position and two stents in a retrograde position (60% complication rate). The configuration most prone to endoleak was one or two stents in retrograde position (33% endoleak rate), followed by three stents in an all-antegrade position (25%). There was a significant correlation between individual stent configuration and stent compromise (P = .0385), with 31

  10. Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Krishnam, Mayil S. [University of California, Cardiovascular and Thoracic Imaging, UCI Medical Center, Irvine, CA (United States); Tomasian, Anderanik; Malik, Sachin; Ruehm, Stefan G. [University of California at Los Angeles, Department of Radiological Sciences, Ronald Reagan Medical Center, Los Angeles, CA (United States); Desphande, Vibhas; Laub, Gerhard [Siemens Medical Solutions, Los Angeles, CA (United States)

    2010-06-15

    The purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases. Fifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined. Abnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P < 0.001) with no significant difference for other aortic segments (P > 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01). Our results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material. (orig.)

  11. Effect of flow on vascular endothelial cells grown in tissue culture on polytetrafluoroethylene grafts

    International Nuclear Information System (INIS)

    Sentissi, J.M.; Ramberg, K.; O'Donnell, T.F. Jr.; Connolly, R.J.; Callow, A.D.

    1986-01-01

    Vascular grafts lined with endothelial cells (EC) grown to confluence in culture before implantation may provide a thromboresistant flow surface. Growth of EC on and their adherence to currently available prosthetic materials under conditions of flow are two impediments remaining in the development of such a graft. To address these problems, 22 polytetrafluoroethylene grafts (PTFE) (5 cm by 4 mm inside diameter) were pretreated with collagen and fibronectin, seeded with 2 to 3 X 10(6) bovine aortic EC per graft, and placed in tissue culture (seeded grafts). Twenty-two grafts pretreated with collagen and fibronectin alone served as controls. After 2 weeks morphologic studies revealed that 20/22 seeded grafts were lined with a confluent endothelial layer. Indium 111-oxine was then used to label the EC-seeded grafts. After exposure to either low (25 ml/min) or high (200 ml/min) flow rates for 60 minutes in an in vitro circuit, examination of the luminal surface of the graft by light microscopy and scanning electron microscopy revealed minimal loss of EC. These findings were corroborated by radionuclide scans that showed an insignificant loss of the EC-associated indium label during exposure to flow (7% low flow, 11% high flow). Pretreatment of PTFE grafts with collagen and fibronectin thus promotes both attachment and adherence of EC even under flow conditions

  12. A Rare Entity: Traumatic Thoracic Aortic Injury in a Patient with Aberrant Right Subclavian Artery.

    Science.gov (United States)

    Patel, Hiten Mohanbhai; Banerjee, Shubhabrata; Bulsara, Shahzad; Sahu, Tapish; Sheorain, Virender K; Grover, Tarun; Parakh, Rajiv

    2017-05-01

    Aberrant right subclavian artery is an uncommon entity incidence ranging from 0.5 to 2.5%. Management of thoracic aortic injury in the presence of such anomalies can be a challenge. We present here a case of traumatic aortic injury, which was incidentally found to have an asymptomatic aberrant right subclavian artery. The patient was managed by an endovascular repair of thoracic aortic injury with an endograft and a right carotid to subclavian artery bypass as a hybrid procedure. A 40-year male patient was brought to the emergency in shock with an alleged history of road traffic accident an hour back. After initial resuscitation as per advance trauma life support protocol, imaging revealed thoracic aortic injury with aberrant right subclavian artery with multiple rib and bilateral humerus fracture. After primary stabilization of arm fractures, the patient was shifted to a hybrid operation room. As the aortic injury was within 10 mm of the origin of both subclavian arteries, it was decided to cover the origin of both subclavian arteries and land the endograft distal to the left carotid artery origin. Since there was a right dominant vertebral artery on imaging, right carotid to right subclavian artery bypass was done with expanded polytetrafluoroethylene graft to prevent posterior circulatory stroke along with thoracic endovascular aortic repair to seal the thoracic aortic injury. After endovascular repair of thoracic aortic injury, left subclavian artery perfusion was maintained through left vertebral artery; and hence, revascularization of left subclavian artery was deferred. After management of all fractures, the patient was discharged 3 weeks after the date of admission without any complications. At 6 months follow-up, patient was stable and images showed patent bypass graft and sealed aortic injury. In a trauma setting with multiple injuries, hybrid procedure with a thoracic endograft is associated with low mortality and morbidity; hence, it is the treatment

  13. Cardiogenic shock due to coronary artery disease associated with interrupted aortic arch

    Directory of Open Access Journals (Sweden)

    Luís Alberto Oliveira Dallan

    2013-06-01

    Full Text Available Acute pulmonary edema is a serious event. Its occurrence in association with interrupted aortic arch and coronary heart disease is rare. Recently, an old patient developed cardiogenic shock and acute pulmonary edema due to acute coronary insufficiency, associated with interrupted aortic arch. The coronary angiography revealed occlusion of the right coronary artery and 95% obstruction in the left main coronary artery, associated with interruption of the descending aorta. Coronary artery bypass graft was performed, without extracorporeal circulation, to the anterior descending coronary artery. We discuss the initial management, given the seriousness of the case.

  14. Expanding TAVI options: elective rotational atherectomy during trans-catheter aortic valve implantation

    International Nuclear Information System (INIS)

    Piccoli, Anna; Lunardi, Mattia; Ariotti, Sara; Ferrero, Valeria; Vassanelli, Corrado; Ribichini, Flavio

    2015-01-01

    Summary: Aortic valve stenosis (AVS) in the elderly is frequently associated to coronary artery disease (CAD). In patients with significant coronary stenosis surgical valve replacement is associated to coronary bypass grafting, but whether coronary angioplasty is needed in patients receiving trans-catheter aortic valve implantation (TAVI) is unknown. Given the frequent complexity of CAD in the elderly with calcific AVS, rotational atherectomy (RA) may be needed in some cases. No data are available about feasibility and safety of RA during TAVI. The need for myocardial revascularization in TAVI candidates is discussed, and a series of RA cases performed during TAVI is described

  15. Three-year-old child with middle aortic syndrome treated by endovascular stent implantation.

    Science.gov (United States)

    Moszura, Tomasz; Goreczny, Sebastian; Dryzek, Pawel; Niwald, Marek

    2013-04-01

    Middle aortic syndrome (MAS) is an extremely rare anomaly and represents both a diagnostic and therapeutic challenge, particularly in young children. A case of a 3.5 year-old child with MAS and arterial hypertension is reported, where owing to the patient's young age and the length of the hypoplastic aortic segment, surgical correction with end-to-end anastomosis was not feasible. Instead of palliative bypass grafting between the thoracic and abdominal aorta, successful percutaneous balloon angioplasty and stenting of the lesion was performed with the assistance of three-dimensional rotational angiography.

  16. Expanding TAVI options: elective rotational atherectomy during trans-catheter aortic valve implantation

    Energy Technology Data Exchange (ETDEWEB)

    Piccoli, Anna; Lunardi, Mattia; Ariotti, Sara; Ferrero, Valeria; Vassanelli, Corrado; Ribichini, Flavio, E-mail: flavio.ribichini@univr.it

    2015-01-15

    Summary: Aortic valve stenosis (AVS) in the elderly is frequently associated to coronary artery disease (CAD). In patients with significant coronary stenosis surgical valve replacement is associated to coronary bypass grafting, but whether coronary angioplasty is needed in patients receiving trans-catheter aortic valve implantation (TAVI) is unknown. Given the frequent complexity of CAD in the elderly with calcific AVS, rotational atherectomy (RA) may be needed in some cases. No data are available about feasibility and safety of RA during TAVI. The need for myocardial revascularization in TAVI candidates is discussed, and a series of RA cases performed during TAVI is described.

  17. Initial Surgical Experience with Aortic Valve Repair: Clinical and Echocardiographic Results

    Directory of Open Access Journals (Sweden)

    Francisco Diniz Affonso da Costa

    Full Text Available Abstract Introduction: Due to late complications associated with the use of conventional prosthetic heart valves, several centers have advocated aortic valve repair and/or valve sparing aortic root replacement for patients with aortic valve insufficiency, in order to enhance late survival and minimize adverse postoperative events. Methods: From March/2012 thru March 2015, 37 patients consecutively underwent conservative operations of the aortic valve and/or aortic root. Mean age was 48±16 years and 81% were males. The aortic valve was bicuspid in 54% and tricuspid in the remaining. All were operated with the aid of intraoperative transesophageal echocardiography. Surgical techniques consisted of replacing the aortic root with a Dacron graft whenever it was dilated or aneurysmatic, using either the remodeling or the reimplantation technique, besides correcting leaflet prolapse when present. Patients were sequentially evaluated with clinical and echocardiographic studies and mean follow-up time was 16±5 months. Results: Thirty-day mortality was 2.7%. In addition there were two late deaths, with late survival being 85% (CI 95% - 68%-95% at two years. Two patients were reoperated due to primary structural valve failure. Freedom from reoperation or from primary structural valve failure was 90% (CI 95% - 66%-97% and 91% (CI 95% - 69%-97% at 2 years, respectively. During clinical follow-up up to 3 years, there were no cases of thromboembolism, hemorrhage or endocarditis. Conclusions: Although this represents an initial series, these data demonstrates that aortic valve repair and/or valve sparing aortic root surgery can be performed with satisfactory immediate and short-term results.

  18. Valve-sparing aortic root replacement in Loeys-Dietz syndrome.

    Science.gov (United States)

    Patel, Nishant D; Arnaoutakis, George J; George, Timothy J; Allen, Jeremiah G; Alejo, Diane E; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A

    2011-08-01

    Loeys-Dietz syndrome (LDS) is a recently recognized aggressive aortic disorder characterized by root aneurysm, arterial tortuosity, hypertelorism, and bifid uvula or cleft palate. The results of prophylactic root replacement using valve-sparing procedures (valve-sparing root replacement [VSRR]) in patients with LDS is not known. We reviewed all patients with clinical and genetic (transforming growth factor-β receptor mutations) evidence of LDS who underwent VSRR at our institution. Echocardiographic and clinical data were obtained from hospital and follow-up clinic records. From 2002 to 2009, 31 patients with a firm diagnosis of LDS underwent VSRR for aortic root aneurysm. Mean age was 15 years, and 24 (77%) were children. One (3%) patient had a bicuspid aortic valve. Preoperative sinus diameter was 3.9±0.8 cm (z score 7.0±2.9) and 2 (6%) had greater than 2+ aortic insufficiency. Thirty patients (97%) underwent reimplantation procedures using a Valsalva graft. There were no operative deaths. Mean follow-up was 3.6 years (range, 0 to 7 years). One patient required late repair of a pseudoaneurysm at the distal aortic anastomosis, and 1 had a conversion to a David reimplantation procedure after a Florida sleeve operation. No patient suffered thromboembolism or endocarditis, and 1 (3%) patient experienced greater than 2+ late aortic insufficiency. No patient required late aortic valve repair or replacement. Loeys-Dietz syndrome is an aggressive aortic aneurysm syndrome that can be addressed by prophylactic aortic root replacement with low operative risk. Valve-sparing procedures have encouraging early and midterm results, similar to those in Marfan syndrome, and are an attractive option for young patients. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Initial clinical experience with a sac-anchoring endoprosthesis for aortic aneurysm repair.

    Science.gov (United States)

    Donayre, Carlos E; Zarins, Christopher K; Krievins, Dainis K; Holden, Andrew; Hill, Andrew; Calderas, Carlos; Velez, Jaime; White, Rodney A

    2011-03-01

    All current aortic endografts depend on proximal and distal fixation to prevent migration. However, migration and rupture can occur, particularly in patients with aortic necks that are short or angulated, or both. We present our initial clinical experience with a new sac-anchoring endoprosthesis designed to anchor and seal the device within the aneurysm sac. The initial worldwide experience using a new endoprosthesis for the treatment of aortic aneurysms (Nellix Endovascular, Palo Alto, Calif) was reviewed. The endoprosthesis consists of dual balloon-expandable endoframes surrounded by polymer-filled endobags designed to obliterate the aneurysm sac and maintain endograft position. Clinical results and follow-up contrast computed tomography (CT) scans at 30 days and 6 and 12 months were reviewed. The endograft was successfully deployed in 21 patients with infrarenal aortic aneurysms measuring 5.7 ± 0.7 cm (range, 4.3-7.4 cm). Two patients with common iliac aneurysms were treated with sac-anchoring extenders that maintained patency of the internal iliac artery. Infusion of 71 ± 37 mL of polymer (range, 19-158 mL) into the aortic endobags resulted in complete aneurysm exclusion in all patients. Mean implant time was 76 ± 35 minutes, with 33 ± 17 minutes of fluoroscopy time and 180 ± 81 mL of contrast; estimated blood loss was 174 ± 116 mL. One patient died during the postoperative period (30-day mortality, 4.8%), and one died at 10 months from non-device-related causes. During a mean follow-up of 8.7 ± 3.1 months and a median of 6.3 months, there were no late aneurysm- or device-related adverse events and no secondary procedures. CT imaging studies at 6 months and 1 year revealed no increase in aneurysm size, no device migration, and no new endoleaks. One patient had a limited proximal type I endoleak at 30 days that resolved at 60 days and remained sealed. One patient has an ongoing distal type I endoleak near the iliac bifurcation, with no change in aneurysm

  20. Endovascular implantation of stent-grafts in the thoracic aorta - mid-term results of a prospective controlled study

    International Nuclear Information System (INIS)

    Duda, S.H.; Pusich, B.; Tepe, G.; Pereira, P.; Feuls, R.; Claussen, C.D.; Raygrotzki, S.; Aebert, H.; Ziemer, G.; Uckmann, F.P.

    2002-01-01

    Purpose: To evaluate the effectiveness and safety of endovascular treatment of various descending thoracic aortic pathologies with covered stent-grafts as an alternative to open surgery. Methods: Among 16 patients (5 type B dissections, 5 contained ruptures, 3 aneurysms of the descending aorta, 1 thoraco-abdominal aneurysm, 1 mural thrombosis, 1 patch aneurysm) treated between November 1997 and November 2000, eight patients received Talent TM stent-grafts and another 8 patients underwent a Gore-TAG TM stent-graft implantation. A clinical follow-up and control CT scans were obtained after the procedure and then at six-month intervals. Results: Deployment of the stent-grafts was technically successful in all cases. Sufficient aortic reconstruction was achieved in all but one patient who needed surgical treatment. One patient died two days after the procedure from aortic rupture due to retrograde type A dissection. Another patient died 19 months after the procedure from an unknown cause. There was no occurrence of distal embolization, paralysis or infection. During follow-up, all patients remained free from recurrence or late complications of their disease. Conclusion: Endoluminal treatment of thoracic aortic pathologies with covered stent-grafts appears to be a safe and feasible method with at least mid-term efficacy. (orig.) [de

  1. Bentall operation, total aortic replacement and mitral valve replacement for a young adult with Marfan syndrome: a case of three-staged operation.

    Science.gov (United States)

    Inui, K; Shimazaki, Y; Watanabe, T; Kuraoka, S; Minowa, T; Miura, M; Oshikiri, S; Toyama, H

    1998-08-01

    In Marfan syndrome, the most common cardiovascular abnormalities are dilatation of the aorta and aortic valve regurgitation in adult patients. Mitral valve dysfunction is the most common cause of morbidity and mortality in infants and children with Marfan syndrome, and is not frequently operated on in adult Marfan patients who undergo surgery for diseases of the aortic root and total aorta. This report describes a successfully three-staged operation for a 24 year-old man with Marfan syndrome who underwent an emergent Bentall operation and aortic arch replacement, total aortic replacement and mitral valve replacement over 2 years. Mitral valve regurgitation was mild but increased after the second operation. The graft was tightly adhesive and invasive to the sternum. Endoscopic view was helpful to avoid graft damage at resternotomy. The postoperative course was uneventful in each operation. Microscopic examination of the mitral valve leaflets showed abnormal increase of mucopolysaccharides, and disruption and fragmentation of elastic fibers.

  2. Aortic obstruction: anatomy and echocardiography

    Directory of Open Access Journals (Sweden)

    Keirns Candace

    2006-09-01

    Full Text Available Abstract Echocardiography is a valuable non-invasive technique for identifying the site and type of aortic obstruction. Knowledge of the morphological details of each type of obstruction is the basis for correct interpretation of the diagnostic images and clinical decisions. This study was undertaken to correlate the echocardiographic images with anatomic specimens of equivalent valvular and supravalvular aortic obstruction. Specimens were part of the collection of the Department of Embryology. Fifty six patients were studied, and forty specimens with aortic obstruction were analyzed. Echocardiographic characteristics: Thirty one (55.3% patients were women and twenty five (44.7% men. Valvular aortic obstruction was found in Thirty six patients (64.3 % and supravalvular aortic obstruction in twenty (35.7%. Anatomic characteristics: Of the forty specimens examined, twenty one (52.5% had valvular aortic obstruction and nineteen (47.5% supravalvular aortic obstruction. The anatomoechocardiographic correlation clearly showed that the anatomic findings of the specimen hearts and aortas corresponded to echocardiographic images of valvular and supravalvular aortic obstruction and provided solid corroboration of echocardiographic diagnoses.

  3. Acute Aortic Arch Perforation During Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis and a Gothic Aortic Arch

    DEFF Research Database (Denmark)

    Millan-Iturbe, Oscar; Sawaya, Fadi J.; Bieliauskas, Gintautas

    2017-01-01

    AS because of its unique anatomic features. This case report describes an acute aortic perforation during delivery of a transcatheter heart valve to treat a severe bicuspid AS with a “gothic aortic arch”; more careful evaluation of the preprocedural multislice computed tomographic scan would have unveiled...

  4. Perioperative management of endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Wang Haofu; Wang Yuwei; Li Jun; Zhao Zonggang; Qi Sen

    2010-01-01

    Objective: To summarize the clinical experience of perioperative management in performing endovascular abdominal aortic aneurysm repair (EVAR). Methods: EVAR was performed in 22 patients with abdominal aortic aneurysm. The clinical data were retrospectively analyzed. Before treatment the functions of main organs were evaluated and certain measures were adopted in order to protect them. Useful parameters, including the length, diameter, angle and configuration of the proximal and distal aneurysmal neck, the relationship of the aneurysm to aortic branches, the distance from the lowest renal artery to the bifurcation of abdominal aorta, and the quality of access vessels (such as diameter, tortuosity and calcification degree) were determined and assessed with CTA. According to the parameters thus obtained, the suitable stent-graft with ideal diameter and length was selected, and the optimal surgery pattern was employed. Local anesthesia was employed in 20 patients, among them the local anesthesia had to be changed to general anesthesia in one. Epidural anesthesia was carried out in one patient through the surgically-reconstructed iliac artery access,and general anesthesia was employed in one patient who had Stanford type A aortic dissection. The lowest renal artery must be accurately localized before deployment of stent-graft was started. At least one patent internal iliac artery should be reserved when bilateral internal iliac arteries needed to be covered, to be covered by stages or to be reconstructed. After stent-graft placement, angiography must be performed to find out if there was any endoleak and, if any, to determine the type of endoleak and to deal with it properly. Two cases had proximal type I endoleak, so balloon dilation was employed in one and cuff implantation in another one. Distal type I endoleak occurred in one case, but, unfortunately, the iliac artery ruptured when balloon dilation was employed, therefore the patient had to receive vascular repair

  5. Contemporary results of surgical repair of recurrent aortic arch obstruction.

    Science.gov (United States)

    Mery, Carlos M; Khan, Muhammad S; Guzmán-Pruneda, Francisco A; Verm, Raymond; Umakanthan, Ramanan; Watrin, Carmen H; Adachi, Iki; Heinle, Jeffrey S; McKenzie, E Dean; Fraser, Charles D

    2014-07-01

    There is a paucity of data on the current outcomes of surgical intervention for recurrent aortic arch obstruction (RAAO) after initial aortic arch repair in children. The goal of this study is to report the long-term results in these patients. All patients undergoing surgical intervention for RAAO at Texas Children's Hospital from 1995 to 2012 were included. The cohort was divided into four groups based on initial procedure: (1) simple coarctation repair, (2) Norwood procedure, (3) complex congenital heart disease, and (4) interrupted aortic arch. A total of 48 patients age 9 months (range, 22 days to 36 years) underwent 49 procedures for RAAO. All patients had an anatomic repair consisting of either patch aortoplasty (n=27, 55%), aortic arch advancement (n=8, 16%), sliding arch aortoplasty (n=6, 12%), placement of an interposition graft (n=2, 17%), reconstruction with donor allograft (n=4, 8%), extended end-to-end anastomosis (n=1, 2%), or redo Norwood-type reconstruction (n=1, 2%). Most procedures (n=46, 94%) were performed through a median sternotomy using cardiopulmonary bypass. At a median follow-up of 6.1 years (range, 9 days to 17 years), only 2 patients required surgical or catheter-based intervention for RAAO. Hypertension was present in 10% of patients at last follow-up. There were no neurologic or renal complications. There was 1 perioperative death after an aortic arch advancement in group 1. Four other patients have died during follow-up, none of the deaths related to RAAO. Anatomic repair of RAAO is a safe procedure associated with low morbidity and mortality, and low long-term reintervention rates. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Inhibition of early AAA formation by aortic intraluminal pentagalloyl glucose (PGG) infusion in a novel porcine AAA model.

    Science.gov (United States)

    Kloster, Brian O; Lund, Lars; Lindholt, Jes S

    2016-05-01

    The vast majority of abdominal aortic aneurysms found in screening programs are small, and as no effective treatment exits, many will expand until surgery is indicated. Therefore, it remains intriguing to develop a safe and low cost treatment of these small aneurysms, that is able to prevent or delay their expansion. In this study, we investigated whether intraluminal delivered pentagalloyl glucose (PGG) can impair the early AAA development in a porcine model. The infrarenal aorta was exposed in thirty pigs. Twenty underwent an elastase based AAA inducing procedure and ten of these received an additional intraluminal PGG infusion. The final 10 were sham operated and served as controls. All pigs who only had an elastase infusion developed macroscopically expanding AAAs. In pigs treated with an additional PGG infusion the growth rate of the AP-diameter rapidly returned to physiological values as seen in the control group. In the elastase group, histology revealed more or less complete resolution of the elastic lamellae in the media while they were more abundant, coherent and structurally organized in the PGG group. The control group displayed normal physiological growth and histology. In our model, intraluminal delivered PGG is able to penetrate the aortic wall from the inside and impair the early AAA development by stabilizing the elastic lamellae and preserving their integrity. The principle holds a high clinical potential if it can be translated to human conditions, since it, if so, potentially could represent a new drug for stabilizing small abdominal aneurysms.

  7. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  8. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Chan, Gabriel; Quek, Lawrence Hwee Han; Tan, Glenn Leong Wei; Pua, Uei

    2016-01-01

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  9. Use of Suture-Mediated Closure Device in Percutaneous Direct Carotid Puncture During Chimney-Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Gabriel, E-mail: dr.changabriel@gmail.com; Quek, Lawrence Hwee Han, E-mail: lawrence-quek@ttsh.com.sg [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore); Tan, Glenn Leong Wei, E-mail: glenn-tan@ttsh.com.sg [Tan Tock Seng Hospital, Department of General Surgery (Singapore); Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2016-07-15

    BackgroundInsertion of a carotid chimney graft during thoracic endovascular aortic repair (Ch-TEVAR) is a recognized technique to extend the proximal landing zone into the aortic arch in the treatment of thoracic aortic disease. Conventional technique requires surgical exposure of the carotid artery for insertion of the carotid chimney graft.MethodologyWe describe our experience in the use of a suture-mediated closure device in percutaneous Ch-TEVAR in four patients.ResultsSuccessful hemostasis was achieved in all four patients. No complications related to the carotid puncture were recorded.ConclusionWe conclude that using suture-mediated closure device for carotid closure appears feasible and deserves further studies as a potential alternative to conventional surgical approach.

  10. Acute Type II Aortic Dissection with Severe Aortic Regurgitation and Chronic Descending Aortic Dissection in Pregnant Patient with Marfan Syndrome.

    Science.gov (United States)

    Lee, Seok-Soo; Jung, Tae-Eun; Lee, Dong Hyup

    2012-12-01

    Aortic dilatation and dissection are severe complications during pregnancy that can be fatal to both the mother and the fetus. The risks of these complications are especially high in pregnant patients with Marfan syndrome; however, incidents of descending aortic dissection are very rare. This case report involves a successful Bentall procedure for and recovery from a rare aortic dissection in a pregnant Marfan patient who developed acute type II aortic dissection with severe aortic regurgitation and chronic descending aortic dissection immediately after Cesarean section. Regular follow-up will be needed to monitor the descending aortic dissection.

  11. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  12. Use of regional mechanical properties of abdominal aortic aneurysms to advance finite element modeling of rupture risk.

    Science.gov (United States)

    Tierney, Áine P; Callanan, Anthony; McGloughlin, Timothy M

    2012-02-01

    To investigate the use of regional variations in the mechanical properties of abdominal aortic aneurysms (AAA) in finite element (FE) modeling of AAA rupture risk, which has heretofore assumed homogeneous mechanical tissue properties. Electrocardiogram-gated computed tomography scans from 3 male patients with known infrarenal AAA were used to characterize the behavior of the aneurysm in 4 different segments (posterior, anterior, and left and right lateral) at maximum diameter and above the infrarenal aorta. The elasticity of the aneurysm (circumferential cyclic strain, compliance, and the Hudetz incremental modulus) was calculated for each segment and the aneurysm as a whole. The FE analysis inclusive of prestress (pre-existing tensile stress) produced a detailed stress pattern on each of the aneurysm models under pressure loading. The 4 largest areas of stress in each region were considered in conjunction with the local regional properties of the segment to define a specific regional prestress rupture index (RPRI). In terms of elasticity, there were average reductions of 68% in circumferential cyclic strain and 63% in compliance, with a >5-fold increase in incremental modulus, between the healthy and the aneurysmal aorta for each patient. There were also regional variations in all elastic properties in each individual patient. The average difference in total stress inclusive of prestress was 59%, 67%, and 15%, respectively, for the 3 patients. Comparing the strain from FE models with the CT scans revealed an average difference in strain of 1.55% for the segmented models and 3.61% for the homogeneous models, which suggests that the segmented models more accurately reflect in vivo behavior. RPRI values were calculated for each segment for all patients. A greater understanding of the local material properties and their use in FE models is essential for greater accuracy in rupture prediction. Quantifying the regional behavior will yield insight into the changes in

  13. Endovascular Aortic Aneurysm Repair for Abdominal Aortic Aneurysm: Single Center Experience in 122 Patients

    International Nuclear Information System (INIS)

    Lee, Yun Young; Song, Jang Hyeon; Kim, Yong Tae; Yim, Nam Yeol; Kim, Jae Kyu; Lee, Ho Kyun; Choi, Soo Jin Na; Chung, Sang Young; Kim, Soo Hyun; Chang, Nam Kyu

    2013-01-01

    To analyze a single center experience of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms. Results of 122 patients who underwent EVAR were analyzed, retrospectively. Sex, age, aneurysmal morphology, hostile neck anatomy, preprocedural and postprocedural sac-diameter, technical and clinical success, postprocedural complication and need of additional procedure were analyzed. A total of 111 male and 11 female patients were included. Morphology of the aneurysms was as follows: fusiform (n = 108), saccular (n = 3) and ruptured type (n = 11). Sixty-four patients had hostile neck anatomy. The preprocedural mean sac-diameter was 52.4 mm. Postprocedural sac-diameter was decreased or stable in 110 patients (90.2%) and increased in 8 patients (6.6%). Technical success rate was 100% and clinical success rate was 86.1%. Fifty-one patients showed endoleak (41.8%) and 15 patients (12.3%) underwent secondary intervention due to type I endoleak (n = 4), type II endoleak (n = 4) and stent-graft thrombosis (n = 7). EVAR is a safe and effective therapy for abdominal aortic aneurysm, and it has high technical success and clinical success rate, and low complication rate.

  14. Osseous scintigraphy and auxiliary graft

    International Nuclear Information System (INIS)

    Khelifa, F.; Siles, S.; Puech, B.

    1992-01-01

    The scintigraphy could be a good way to survey the osseous graft: three cases are studied in which were recognized the presence of a graft, surinfection, graft lysis, pseudo-arthrosis, algodystrophy. 8 refs., 5 figs

  15. Meniscal allograft transplantation. Part 1: systematic review of graft biology, graft shrinkage, graft extrusion, graft sizing, and graft fixation.

    Science.gov (United States)

    Samitier, Gonzalo; Alentorn-Geli, Eduard; Taylor, Dean C; Rill, Brian; Lock, Terrence; Moutzouros, Vasilius; Kolowich, Patricia

    2015-01-01

    To provide a systematic review of the literature regarding five topics in meniscal allograft transplantation: graft biology, shrinkage, extrusion, sizing, and fixation. A systematic literature search was conducted using the PubMed (MEDLINE), ScienceDirect, and EBSCO-CINAHL databases. Articles were classified only in one topic, but information contained could be reported into other topics. Information was classified according to type of study (animal, in vitro human, and in vivo human) and level of evidence (for in vivo human studies). Sixty-two studies were finally included: 30 biology, 3 graft shrinkage, 11 graft extrusion, 17 graft size, and 6 graft fixation (some studies were categorized in more than one topic). These studies corresponded to 22 animal studies, 22 in vitro human studies, and 23 in vivo human studies (7 level II, 10 level III, and 6 level IV). The principal conclusions were as follows: (a) Donor cells decrease after MAT and grafts are repopulated with host cells form synovium; (b) graft preservation alters collagen network (deep freezing) and causes cell apoptosis with loss of viable cells (cryopreservation); (c) graft shrinkage occurs mainly in lyophilized and gamma-irradiated grafts (less with cryopreservation); (d) graft extrusion is common but has no clinical/functional implications; (e) overall, MRI is not superior to plain radiograph for graft sizing; (f) graft width size matching is more important than length size matching; (g) height appears to be the most important factor influencing meniscal size; (h) bone fixation better restores contact mechanics than suture fixation, but there are no differences for pullout strength or functional results; and (i) suture fixation has more risk of graft extrusion compared to bone fixation. Systematic review of level II-IV studies, Level IV.

  16. Abdominal Aortic Emergencies.

    Science.gov (United States)

    Lech, Christie; Swaminathan, Anand

    2017-11-01

    This article discusses abdominal aortic emergencies. There is a common thread of risk factors and causes of these diseases, including age, male gender, hypertension, dyslipidemia, and connective tissue disorders. The most common presenting symptom of these disorders is pain, usually in the chest, flank, abdomen, or back. Computed tomography scan is the gold standard for diagnosis of pathologic conditions of the aorta in the hemodynamically stable patient. Treatment consists of a combination of blood pressure and heart rate control and, in many cases, emergent surgical intervention. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Acute Type II Aortic Dissection with Severe Aortic Regurgitation and Chronic Descending Aortic Dissection in Pregnant Patient with Marfan Syndrome

    OpenAIRE

    Lee, Seok-Soo; Jung, Tae-Eun; Lee, Dong Hyup

    2012-01-01

    Aortic dilatation and dissection are severe complications during pregnancy that can be fatal to both the mother and the fetus. The risks of these complications are especially high in pregnant patients with Marfan syndrome; however, incidents of descending aortic dissection are very rare. This case report involves a successful Bentall procedure for and recovery from a rare aortic dissection in a pregnant Marfan patient who developed acute type II aortic dissection with severe aortic regurgitat...

  18. Valve-sparing aortic root replacement and aortic valve repair in a patient with acromegaly and aortic root dilatation

    Directory of Open Access Journals (Sweden)

    Karel Van Praet

    2015-07-01

    Full Text Available Aortic regurgitation and dilatation of the aortic root and ascending aorta are severe complications of acromegaly. The current trend for management of an aortic root aneurysm is valve-sparing root replacement as well as restoring the diameter of the aortic sinotubular junction (STJ and annulus. Our case report supports the recommendation that in patients with acromegaly, severe aortic root involvement may indicate the need for surgery.

  19. Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases

    International Nuclear Information System (INIS)

    Krishnam, Mayil S.; Tomasian, Anderanik; Malik, Sachin; Ruehm, Stefan G.; Desphande, Vibhas; Laub, Gerhard

    2010-01-01

    The purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases. Fifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined. Abnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01). Our results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material. (orig.)

  20. Advances in radiation grafting

    International Nuclear Information System (INIS)

    Hegazy, El-Sayed A.; AbdEl-Rehim, H.A.; Kamal, H.; Kandeel, K.A.

    2001-01-01

    Graft copolymerization is an attractive means for modifying base polymers because grafting frequently results in the superposition of properties relating to the backbone and pendent chains. Among the various methods for initiating the grafting reaction, ionizing radiation is the cleanest and most versatile method of grafting available. Ion-exchange membranes play an important role in modern technology, especially in separation and purification of materials. The search for improved membrane composition has considered almost every available polymeric material because of its great practical importance. Grafting of polymers with a mixture of monomers is important since different types of chains containing different functional groups are included. A great deal is focused on the waste treatment of heavy and toxic metals from wastewater because of the severe problems of environmental pollution. Functionalized polymers suitable for metal adsorption with their reactive functional groups such as carboxylic and pyridine groups suitable for waste treatment were prepared by radiation grafting method. More reactive chelating groups were further introduced to the grafted copolymer through its functional groups by chemical treatments with suitable reagents. The advances of radiation grafting and possible uses are briefly discussed

  1. Bone graft revascularization strategies

    NARCIS (Netherlands)

    Willems, W.F.

    2014-01-01

    Reconstruction of avascular necrotic bone by pedicled bone grafting is a well-known treatment with little basic research supporting its application. A new canine model was used to simulate carpal bone avascular necrosis. Pedicled bone grafting proved to increase bone remodeling and bone blood flow,

  2. Unusual Case of Overt Aortic Dissection Mimicking Aortic Intramural Hematoma

    Directory of Open Access Journals (Sweden)

    Kushtrim Disha

    2016-04-01

    Full Text Available We report an interesting case in which overt aortic dissection mimicked two episodes of aortic intramural hematoma (IMH (Stanford A, DeBakey I. This took place over the course of four days and had a major influence on the surgical treatment strategy. The first episode of IMH regressed completely within 15 hours after it was clinically diagnosed and verified using imaging techniques. The recurrence of IMH was detected three days thereafter, resulting in an urgent surgical intervention. Overt aortic dissection with evidence of an intimal tear was diagnosed intraoperatively.

  3. Reinforced aortic root reconstruction for acute type A aortic dissection involving the aortic root

    Directory of Open Access Journals (Sweden)

    Han Qing-qi

    2013-06-01

    Full Text Available OBJECTIVE: There are debates regarding the optimal approach for AAAD involving the aortic root. We described a modified reinforced aortic root reconstruction approach for treating AAAD involving the aortic root. METHODS: A total of 161 patients with AAAD involving the aortic root were treated by our modified reinforced aortic root reconstruction approach from January 1998 to December 2008. Key features of our modified approach were placement of an autologous pericardial patch in the false lumen, lining of the sinotubular junction lumen with a polyester vascular ring, and wrapping of the vessel with Teflon strips. Outcome measures included post-operative mortality, survival, complications, and level of aortic regurgitation. RESULTS: A total of 161 patients were included in the study (mean age: 43.3 1 15.5 years. The mean duration of follow-up was 5.1 1 2.96 years (2-12 years. A total of 10 (6.2% and 11 (6.8% patients died during hospitalization and during follow-up, respectively. Thirty-one (19.3% patients experienced postoperative complications. The 1-, 3-, 5-, and 10-year survival rates were 99.3%, 98%, 93.8%, and 75.5%, respectively. There were no instances of recurrent aortic dissection, aortic aneurysm, or pseudoaneurysm during the entire study period. The severity of aortic regurgitation dramatically decreased immediately after surgery (from 28.6% to 0% grade 3-4 and thereafter slightly increased (from 0% to 7.2% at 5 years and 9.1% at 10 years. CONCLUSION: This modified reinforced aortic root reconstruction was feasible, safe and durable/effective, as indicated by its low mortality, low postoperative complications and high survival rate.

  4. Comparison of aortic root replacement in patients with Marfan syndrome.

    Science.gov (United States)

    Bernhardt, Alexander M J; Treede, Hendrik; Rybczynski, Meike; Sheikzadeh, Sara; Kersten, Jan F; Meinertz, Thomas; von Kodolitsch, Yskert; Reichenspurner, Hermann

    2011-11-01

    Although the aortic-valve-sparing (AVS) reimplantation technique according to David has shown favorable durability results in mid-term and long-term studies, composite valve grafting (CVG) according to Bentall is still considered the standard procedure. Retrospectively, we evaluated the results of aortic root replacement of patients with Marfan syndrome (MFS) who underwent surgery between January 1995 and January 2010. MFS was diagnosed using the Ghent criteria. AVS was used in 58 patients and CVG in 30 patients with MFS. AVS was done for aortic-root aneurysm (n=48) or aortic dissection type A (n=10). CVG was used for aortic-root aneurysm in 14 patients or aortic dissection type A in 16 patients. The mean follow-up was 3.2 (95% CI: 2.4-4.2) years. In both groups, 30-day mortality was 0%. Three patients (10.0%) in the CVG group required resternotomy for postoperative bleeding versus two patients (3.4%) in the AVS group (p=0.3). At follow-up, mortality was 10% in the CVG group versus 3.4% in the AVS group (p=0.3). Re-operation was required in two patients (3.4%) after AVS and in three patients after CVG (10%) (p=0.3). Three patients (10.0%) who underwent CVG had endocarditis and two patients (6.7%) had a stroke during follow-up, whereas no endocarditis and stroke occurred after AVS. After 14 years, stratified event-free survival was better in the AVS group (event-free survival was 82.3% vs 58.6%, log-rank test p=0.086), especially after aneurysm (p=0.057). After 10 years, freedom from aortic regurgitation ≥II° in the AVS group was 80% for aneurysm and 50% after dissection (p=0.524). The reimplantation technique according to David was associated with excellent survival, good valve function and a low rate of re-operation, endocarditis, and stroke. There was a trend to better event-free survival for AVS patients making it the procedure of choice in MFS patients. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights

  5. Detection of acute synthetic vascular graft infection with IN-111 labeled leukocyte imaging

    International Nuclear Information System (INIS)

    Alazraki, N.; Dries, D.; Lawrence, P.; Murphy, K.; Kercher, J.; Datz, F.; Christian, P.; Taylor, A.

    1985-01-01

    Synthetic vascular graft infection is characterized by late diagnosis due to indolent and nonspecific symptoms. Reported data on accuracy of In-111 labeled leukocyte imaging to identify vascular graft infection is sparse and conflicting. The purpose of this animal study was to clarify the accuracy of detection of early graft infection using a mixed population of In-111 labeled leukocytes. Twelve mongrel dogs received dacron aortic interposition grafts. Seven grafts were contaminated at surgery by topical ATCC S. aureus, 10/sup 8/ organisms per ml. Six control animals received no graft contamination Mixed population In-111 homologous leukocyte labeling was performed followed by imaging at 24 and 48 hours following intravenous injection of 250 μCi In-111 leukocytes. Scans were done on Day 2 post-surgery. Infected dogs were sacrificed following Indium imaging; control dogs were rescanned at 3 weeks postop and sacrificed thereafter. Autopsy results were correlated with scans, yielding sensitivity 71%, specificity 100%, accuracy 85% for In-111 leukocyte imaging to detect early graft infection. False positive leukocyte imaging in the early postop period was not a problem. At autopsy all 5 dogs with infected grafts and positive scans had gross pus. The 2 dogs with false negative scans showed no gross pus at autopsy; cultures were positive for S. aureus in all 7 dogs. Scans at 2 days and 3 weeks post-surgery were true negatives in all 6 control dogs. These data suggest a high level of clinical reliability of leukocyte imaging for early graft infection detection

  6. Current indications for stentless aortic bioprostheses.

    Science.gov (United States)

    Hegazy, Yasser Y; Rayan, Amr; Bauer, Stefan; Keshk, Noha; Bauer, Kerstin; Ennker, Ina; Ennker, Jürgen

    2018-01-01

    The best aortic prostheses have been debated for decades. The introduction of stentless aortic bioprostheses was aimed at improving hemodynamics and potentially the durability of aortic bioprostheses. Despite the good short- and long-term outcomes after implantation of stentless aortic bioprostheses, their use remains limited owing to the technically demanding implantation techniques. Nevertheless, stentless aortic bioprostheses might be of special benefit in certain indications, where they could be a valuable addition to the surgical armamentarium.

  7. Flow and wall shear stress characterization after endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model.

    Science.gov (United States)

    Boersen, Johannes T; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H; Ku, David N; de Vries, Jean-Paul P M; Reijnen, Michel M P J

    2017-12-01

    Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is different from a bifurcation with a tapered trajectory of the flow lumen into the two limbs and may induce unfavorable flow conditions. These include low and oscillatory wall shear stress (WSS), linked to atherosclerosis, and high shear rates that may result in thrombosis. An in vitro study was performed to assess the impact of EVAR and EVAS on flow patterns and WSS. Four abdominal aortic aneurysm phantoms were constructed, including three stented models, to study the influence of the flow divider on flow (Endurant [Medtronic, Minneapolis, Minn], AFX [Endologix, Irvine, Calif], and Nellix [Endologix]). Experimental models were tested under physiologic resting conditions, and flow was visualized with laser particle imaging velocimetry, quantified by shear rate, WSS, and oscillatory shear index (OSI) in the suprarenal aorta, renal artery (RA), and common iliac artery. WSS and OSI were comparable for all models in the suprarenal aorta. The RA flow profile in the EVAR models was comparable to the control, but a region of lower WSS was observed on the caudal wall compared with the control. The EVAS model showed a stronger jet flow with a higher shear rate in some regions compared with the other models. Small regions of low WSS and high OSI were found near the distal end of all stents in the common iliac artery compared with the control. Maximum shear rates in each region of interest were well below the pathologic threshold for acute thrombosis. The different stent designs do not influence suprarenal flow. Lower WSS is observed in the caudal wall of the RA after EVAR and a higher shear rate after EVAS. All stented models have a small region of low WSS and high OSI near the distal outflow

  8. How to manage a case of aymptomatic thoraco-abdominal aortic aneurysm with occluded mesenteric arteries

    Directory of Open Access Journals (Sweden)

    Abhisekh Mohanty

    2015-12-01

    Full Text Available We report a unique case of a 57-year-old male having a suprarenal thoraco-abdominal aortic aneurysm which is extending till the origin of superior mesenteric artery (SMA. The origins of celiac artery and SMA were totally occluded and filled retrogradely through dense collateral vessels arising from the inferior mesenteric artery. Surprisingly, the patient was not having any symptoms related to mesenteric ischemia. We decided to use a conventional aortic aneurysm stent graft to repair it without revascularizing the occluded mesenteric arteries. After 1 month, CT aortogram was repeated which revealed a well-apposed stent graft with no endoleaks. He did not have any clinical signs and symptoms attributable to mesenteric ischemia.

  9. Prevention of paraplegia after endovascular exclusion for stanford B thoracic aortic dissection aneurism

    International Nuclear Information System (INIS)

    Feng Rui; Jing Zaiping; Bao Junmin; Zhao Zhiqing; Zhao Jun; Feng Xiang; Lu Qingsheng; Huang Cheng

    2003-01-01

    Objective: To assess the prophylactic measures of paraplegia and paralysis after endovascular graft exclusion (EVE) for Stanford B thoracic aortic dissections (TAD). Methods: The records of 116 consecutive patients undergoing endovascular TAD repair from 1998 to 2001 were retrospectively reviewed. Steroids were administrated postoperatively in high risk patients likely to be candidates for paraplegia or paralysis. Results: No paraplegia or paralysis occurred postoperatively in all cases, including the patient undergone selective spinal artery angiography (SSAA). Conclusions: Transluminal repair can avoid spinal cord ischemia due to aortic cross-clamping, there is still a risk of spinal cord injury caused by occlusion of intercostal arteries under the cover of endograft. A combination of the prophylactic measures, including SSAA and steroids, have been able to reduce the risk of paraplegia and paralysis. A graft-stent of appropriate length is the key point of this procedure

  10. Duodenal Obstruction after Elective Abdominal Aortic Aneurysm Repair: A Case Report

    Directory of Open Access Journals (Sweden)

    Chun-Yao Lin

    2004-10-01

    Full Text Available Gastrointestinal tract complications after abdominal aortic aneurysm (AAA repair are well known. The reported frequency ranges from 6.6% to 21%. However, the incidence of duodenal obstruction following AAA has probably been underestimated. This report concerns a 78-year-old male who was admitted for elective repair of an infrarenal AAA. On the ninth postoperative day, the patient presented with large quantities of bile-stained vomitus despite passing flatus per rectum. Metoclopramide and ranitidine were given under the initial impression of paralytic ileus. However, the upper gastrointestinal obstruction persisted, and on day 12, computerized tomography (CT revealed marked distension of the gastric tube and duodenum, down to the level of the third portion, with abrupt change of caliber at the point of the superior mesenteric artery (SMA. SMA syndrome was diagnosed. After nasogastric tube aspiration, parenteral nutrition, and 11 days of conservative treatment, abdominal CT and upper gastrointestinal series showed no apparent duodenal obstruction. The patient was discharged on the 29th postoperative day; follow-up abdominal CT 4 months later was unremarkable.

  11. Screening for abdominal aortic aneurysms Rastreamento de aneurismas da aorta abdominal

    Directory of Open Access Journals (Sweden)

    Telmo Pedro Bonamigo

    2003-01-01

    Full Text Available OBJECTIVE AND METHODS: Screening for abdominal aortic aneurysms may be useful to decrease mortality related to rupture. We conducted a study to assess the prevalence of abdominal aortic aneurysms in southern Brazil and to define risk factors associated with high prevalence of this disorder. The screening was conducted using abdominal ultrasound. Three groups were studied: Group 1 - cardiology clinic patients; Group 2 - individuals with severe ischemic disease and previous coronary surgery, or important lesions on cardiac catheterism; Group 3 - individuals without cardiac disease selected from the general population. All individuals were male and older than 54 years of age. The ultrasonographic diagnosis of aneurysm was based on an anteroposterior abdominal aorta diameter of 3 cm, or on an abdominal aorta diameter 0.5 cm greater than that of the supra-renal aorta. RESULTS: A total of 2.281 people were screened for abdominal aortic aneurysms in all groups: Group 1 - 768 individuals, Group 2 - 501 individuals, and Group 3 - 1012 individuals. The prevalence of aneurysms was 4.3%, 6.8% and 1.7%, respectively. Age and cigarette smoking were significantly associated with increased prevalence of aneurysms, as was the diagnosis of peripheral artery disease. DISCUSSION: We concluded that screening may be an important tool to prevent the mortality associated with abdominal aortic aneurysms surgery. Additionally, the cost of screening can be decreased if only individuals presenting significant risk factors, such as coronary and peripheral artery disease, smokers and relatives of aneurysm patients, are examined.OBJETIVO E MÉTODOS: O rastreamento de aneurisma da aorta abdominal infra-renal é importante pois pode diminuir a mortalidade relacionada à ruptura. Realizamos um estudo para definir a prevalência desses aneurismas em diversos segmentos da população em nossa região do Brasil. O rastreamento foi realizado utilizando-se a ecografia de abdômen. Tr

  12. Tobacco smoking and aortic aneurysm

    DEFF Research Database (Denmark)

    Sode, Birgitte F; Nordestgaard, Børge; Grønbæk, Morten

    2013-01-01

    BACKGROUND: We determined the predictive power of tobacco smoking on aortic aneurysm as opposed to other risk factors in the general population. METHODS: We recorded tobacco smoking and other risk factors at baseline, and assessed hospitalization and death from aortic aneurysm in 15,072 individuals...... aneurysm in males and females consuming above 20g tobacco daily was 3.5% and 1.3%, among those >60years with plasma cholesterol >5mmol/L and a systolic blood pressure >140mmHg. CONCLUSIONS: Tobacco smoking is the most important predictor of future aortic aneurysm outcomes in the general population...

  13. O tratamento operatório da dissecção aórtica crônica tipo A em pacientes submetidos à revascularização cirúrgica do miocárdio Surgical treatment of chronic type A aortic dissection in patients undergoing coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    João Carlos Leal

    2010-09-01

    Full Text Available O tratamento operatório da dissecção aórtica é um desafio para o cirurgião cardíaco, sobretudo nos pacientes submetidos a operação cardíaca prévia. Nosso objetivo neste relato de caso é demonstrar como tratamos a dissecção aórtica crônica tipo A em paciente revascularizado utilizando cânulas arterial e venosa percutâneas.Surgical treatment of aortic dissection is a challenge for the cardiac surgeon, especially in patients undergoing cardiac operations. Our objective in this case report is to demonstrate how we treat the chronic type A aortic dissection in patients revascularized using percutaneous arterial and venous cannulae.

  14. Sequential Hybrid Repair of Aorta and Bilateral Common Iliac Arteries Secondary to Chronic Aortic Dissection with Extensive Aneurysmal Degeneration in a Marfan Patient.

    Science.gov (United States)

    Hinojosa, Carlos A; Anaya-Ayala, Javier E; Laparra-Escareno, Hugo; Lizola, Rene; Torres-Machorro, Adriana

    2017-09-01

    Marfan syndrome is a connective tissue disorder associated with aortic dissection, aneurysmal degeneration and rupture. These cardiovascular complications represent the main cause of mortality, therefore repair is indicated. We present a 35-year-old woman who experienced acute onset of chest pain. Her imaging revealed a chronic DeBakey type I dissection with aortic root dilation and descending thoracic aneurysmal degeneration. She underwent a Bentall procedure and endovascular exclusion of the descending thoracic aortic aneurysm. She was closely followed and 2 years later a computed tomography angiography (CTA) revealed the aneurysmal degeneration of the thoracoabominal aorta and bilateral iliac arteries. The patient underwent a composite reconstruction using multi-visceral branched and bifurcated Dacron grafts. At 5 years from her last surgery, a CTA revealed no new dissection or further aneurysmal degenerations. Aortic disease in Marfan patients is a complex clinical problem that may lead to secondary or tertiary aortic reconstructions; close follow-up is mandatory.

  15. Recognition and treatment of outflow tract stenosis during and after endovascular exclusion for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Lu Qingsheng; Jing Zaiping; Zhao Zhiqing; Bao Junmin; Zhao Jun; Feng Xiang; Feng Rui; Huang Sheng

    2003-01-01

    Objective: To study the cognition and treatment of outflow tract stenosis in and after endovascular exclusion for abdominal aortic aneurysm. Methods: From Mar 1997 to Oct 2002, in 136 patients undergoing abdominal aortic aneurysm endovascular exclusion, 8 patients had outflow tract stenosis during the operation, and 3 patients had outflow tract stenosis after operation. The stenosis of 5 patients occurred at the crotch of the graft-stent. PTA was done in 7 patients and stents were placed in stenotic segment in 2 patients. 2 patients were treated with crossover operation. Results: Following up 1 month to 2 years, all patients have no lower limbs ischemia. Conclusions: The diagnosis of outflow tract stenosis during and after abdominal endovascular exclusion for aortic aneurysm must be in time. The treatment should be according to the different causes of stenosis

  16. Systemic aspergilloma post aortic root surgery following coronary artery stenting: diagnostic and management dilemma

    Science.gov (United States)

    Hussein, Nabil; Qamar, Sombul; Abid, Qamar

    2015-01-01

    Aspergillus infections such as Aspergillus endocarditis were once relatively rare occurrences, however, due to the increased use of intracardiac devices, the incidence has grown. With mortality rates close to 100%, in medically treated cases, it is paramount that early diagnosis and treatment are performed. An immunocompetent aviculturist presented 8 months post aortic root replacement for severe aortic regurgitation with a composite graft, with central crushing chest pain. Investigations confirmed ST elevation inferior myocardial infarction due to stenosis of the origin of the right coronary artery, which was stented. Echocardiogram demonstrated a mobile mass posterior to the left ventricular outflow tract. Following referral to our cardiothoracic surgeons, a polypoidal mass covering the right ostial button was noted along with systemic complications of the disease. Emergency redo aortic valve replacement with a homograft and coronary artery bypass was performed. Histological analysis confirmed A. fumigatus and the patient was started on intravenous voriconazole. PMID:26025972

  17. Endovascular treatment of thoracic aortic pseudoaneurysm due to brucellosis: a rare case report.

    Science.gov (United States)

    Wang, Shuai; Wang, Qi; Liu, Han; Sun, Siqiao; Sun, Xiwei; Zhang, Yang; Wang, Zhongying; Cheng, Zhihua

    2017-06-02

    Arterial damage is a known complication of brucellosis, but the occurrence of a thoracic aortic pseudoaneurysm secondary to brucellosis has not been previously reported. A 65-year-old Chinese man presented with a pseudoaneurysm in the descending segment of the thoracic aorta that caused symptoms of chest pain and intermittent fever. He was diagnosed with a thoracic aortic pseudoaneurysm secondary to brucellosis based on a positive brucella serology test (standard-tube agglutination test) and imaging examination (computed tomography angiography). Anti-brucellosis treatment and covered stent graft implantation were attempted to eliminate the brucellosis and pseudoaneurysm, respectively, and were ultimately successful, with no symptoms after 6 months of follow-up. Endovascular repair may be effective and safe for treating a thoracic aortic pseudoaneurysm resulting from brucellosis.

  18. Early Results of the PETTICOAT Technique for the Management of Acute Type A Aortic Dissection.

    Science.gov (United States)

    Kotha, Vamshi Krishna; Pozeg, Zlatko I; Herget, Eric J; Moon, Michael C; Appoo, Jehangir J

    2017-08-01

    Conventional surgical techniques for acute Type A aortic dissection (ATAAD) generally fail to address residual dissection in the descending aorta. The persistence of a false lumen is associated with visceral malperfusion in the acute setting and adverse aortic remodeling in the chronic setting. Hybrid aortic arch repair techniques may improve perioperative and long-term mortality by expanding the true lumen and obliterating the false lumen. However, there is a limit to the extent of aortic coverage due to the concomitant risk of spinal cord ischemia. In Type B dissection, the PETTICOAT (Provisional Extension To Induce Complete Attachment) technique, which entails stent graft coverage of the primary intimal tear followed by bare metal stent placement distally, may improve true lumen caliber and promote false lumen thrombosis without increasing the risk of spinal cord ischemia, as intercostal branches remain perfused through the bare metal stents. The technique of hybrid arch with surgical creation of a Dacron landing zone covering a stent graft in the proximal descending aorta and bare metal stents in the thoraco-abdominal aorta is a promising concept in the treatment of ATAAD.

  19. The bicuspid aortic valve and its relation to aortic dilation

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2010-01-01

    Full Text Available BACKGROUND: A bicuspid aortic valve (BAV is a common congenital heart disease, which affects 1-2% of the population. However, the relationship between BAVs and aortic dilation has not been sufficiently elucidated. METHODS: A total of 241 BAV patients who were referred to this hospital for cardiac surgey over a 4.75-year period were included in this study. In addition to the clinical characteristics of the included patients, the morphological features of the aortic valve and aorta, the length of the left main coronary artery, and the laboratory findings (the coagulation and hematological parameters as well as the total cholesterol concentration were determined and compared with those of the tricuspid aortic valve (TAV patients. RESULTS: The BAV patients were younger than the TAV patients for a valve surgery in the last 3 months of the study period. The BAV patients were predominantly male. Most of the BAVs that were surgically treated were stenotic, regurgitant, or combined, and only 19 (7.88% were normally functioning valves. According to echocardiography or operative records, 148 (78.31% were type A, 31 (16.40% were type B, and 10 (5.29% were type C. The left main coronary artery was much shorter in the BAV patients than it was in the TAV patients. There was no significant difference between BAV and TAV patients in the total cholesterol concentrations; whereas differences were noted between patients receiving lipid-lowering therapy and those not receiving lipid-lowering therapy. The dimensions of the aortic root, sinotubular junction, and ascending aorta were beyond normal limits, while they were significantly smaller in the BAV patients than in the TAV patients. They were also much smaller in patients receiving statin therapy than those not receiving statin therapy in both groups. Moreover, the aortic dilation in the BAV group was found to be significantly associated with patient age. CONCLUSIONS: The BAV patients developed aortic wall and

  20. Abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Lindholt, Jes S.

    2010-01-01

    Although the number of elective operations for abdominal aortic aneurysms (AAA) is increasing, the sex- and age-standardised mortality rate of AAAs continues to rise, especially among men aged 65 years or more. The lethality of ruptured AAA continues to be 80-95%, compared with 5-7% by elective...... surgery of symptomfree AAA. In order to fulfil all WHO, European, and Danish criteria for screening, a randomised hospitalbased screening trial of 12,639 65-73 year old men in Viborg County (Denmark) was initiated in 1994. It seemed that US screening is a valid, suitable and acceptable method of screening...... patients without previous hospital discharge diagnoses due to cardiovascular disease than among similar men without AAA. The absolute risk difference after 5 years was 16%. So, they will benefit from general cardiovascular preventive action as smoking cessation, statins and low-dose aspirin, which could...

  1. Abdominal aortic aneurysm surgery

    DEFF Research Database (Denmark)

    Gefke, K; Schroeder, T V; Thisted, B

    1994-01-01

    The goal of this study was to identify patients who need longer care in the ICU (more than 48 hours) following abdominal aortic aneurysm (AAA) surgery and to evaluate the influence of perioperative complications on short- and long-term survival and quality of life. AAA surgery was performed in 553...... patients, 51 (9%) of whom died within the first 48 hours. Of the 502 patients who survived for more than 48 hours, 109 required ICU therapy for more than 48 hours, whereas 393 patients were in the ICU for less than 48 hours. The incidence of preoperative risk factors was similar for the two groups...... combined failed to permit identification of patients in whom the perioperative survival rate was 0%. Even 20% of patients with multiorgan failure survived for 6 months. Of those patients who needed ICU therapy for more than 48 hours, 41 (38%) were alive at the end of 1988. In response to a questionnaire...

  2. Evaluation of the aortic anulus

    International Nuclear Information System (INIS)

    Link, K.M.; Margosian, P.

    1991-01-01

    This paper evaluates the efficacy of echocardiography and MR imaging for measuring the aortic anulus in patients who are candidates for aortic valve replacement. The MR imaging study was performed on a 1.5-T system, and the results were compared with echocardiography results obtained with use of a Toshiba system with a 2.5-mHz transducer. The aortic valve anulus was evaluated in the coronal, long-axis, and short-axis views with the MR imaging technique and in the right parasternal suprasternal, and apical projections with the echocardiographic technique. Twenty-four patients studied with MR imaging and echocardiography went on to have aortic valve replacement. When compared with surgical results, MR imaging had an r value of .95 while echocardiography had an r value of .70

  3. Open Treatment of Blunt Injuries of Supra-Aortic Branches: Case Series.

    Science.gov (United States)

    Sladojevic, Milos; Markovic, Miroslav; Ilic, Nikola; Pejkic, Sinisa; Banzic, Igor; Djoric, Predrag; Koncar, Igor; Tomic, Ivan; Davidovic, Lazar

    2016-02-01

    Blunt injuries of the supra-aortic branches are rare entity, and majority of patients die before arrival at the hospital. Those who arrive alive require complex and fast procedure that requires sternotomy. We report 3 successfully managed cases. We report 3 patients with injury of supra-aortic branches. One was treated urgently due to longitudinal rupture on the posterior wall of innominate artery after car accident, and another 2 had chronic false aneurysm located at the very orifice of the right subclavian and left common carotid artery. In first and second patient bypass grafting with a hand-made, Y-shaped, 8-mm Dacron graft from the ascending aorta to the right common carotid and proximal right subclavian artery were performed, whereas in last 1 bypass grafting from the ascending aorta to the cervical part of the left common carotid artery was performed. In our facility, there were no possibilities for any endovascular treatment. When endovascular technology is not available, open surgical repair of blunt injuries of supra-aortic vessels can be performed without complications. No matter to that, endovascular and hybrid procedures should be considered whenever possible. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Risk factors and early outcomes of acute renal injury after thoracic aortic endograft repair for type B aortic dissection

    Directory of Open Access Journals (Sweden)

    Luo S

    2017-08-01

    Full Text Available Songyuan Luo,* Huanyu Ding,* Jianfang Luo, Wei Li, Bing Ning, Yuan Liu, Wenhui Huang, Ling Xue, Ruixin Fan, Jiyan Chen Cardiology Department, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of Coronary Heart Disease Prevention, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, China *These authors contributed equally to this work Background: Thoracic endovascular aortic repair (TEVAR has become an emerging treatment modality for acute type B aortic dissection (TBAD patients in recent years. The risk factors and impacts of acute kidney injury (AKI after percutaneous TEVAR, however, have not been widely established.Methods: We retrospectively studied the clinical records of 305 consecutive patients who admitted to our institution and had TEVAR for TBAD between December 2009 and June 2013. The patients were routinely monitored for their renal functions preoperatively until 7 days after TEVAR. The Kidney Disease Improving Global Guidelines (KDIGO criteria were used for AKI.Results: Of the total 305 consecutive patients, 84 (27.5% developed AKI after TEVAR, comprising 66 (21.6% patients in KDIGO stage 1, 6 (2.0% patients in stage 2 and 12 (3.9% patients in stage 3. From the logistic regression analysis, systolic blood pressure (SBP on admission >140 mmHg (odds ratio [OR], 2.288; 95% CI, 1.319–3.969 and supra-aortic branches graft bypass hybrid surgery (OR, 3.228; 95% CI, 1.526–6.831 were independent risk factors for AKI after TEVAR. Local anesthesia tended to be a protective factor (OR, 0.563; 95% CI, 0.316–1.001. The preoperative renal function, angiotensin-converting enzyme inhibitor/angiotensin receptor blocker or statin administration, volume of contrast agent, range of TBAD and false lumen involving renal artery were not associated with post-operation AKI. The in-hospital mortality and major adverse events were markedly increased with the occurrence of AKI (7.1% vs 0.9%, P=0

  5. Imaging techniques in transcatheter aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Quaife RA

    2013-11-01

    Full Text Available Robert A Quaife, Jennifer Dorosz, John C Messenger, Ernesto E Salcedo Division of Cardiology, University of Colorado, Aurora, CO, USA Abstract: Calcific aortic stenosis is now understood as a complex valvular degenerative process sharing many risk factors with atherosclerosis. Once patients develop symptomatic calcific aortic stenosis, the only effective treatment is aortic valve replacement. In the past decade, transcatheter aortic valve replacement (TAVR has been developed as an alternative to surgery to treat severe calcific aortic stenosis. Cardiac imaging plays a pivotal role in the contemporary management of patients with calcific aortic stenosis, and particularly in patients being considered for TAVR, who demand detailed imaging of the aortic valve apparatus. In this review, we highlight the role of cardiac imaging for patient selection, procedural guidance, and evaluation of results of TAVR. Keywords: aortic stenosis, cardiovascular imaging, transcutaneous aortic valve replacement

  6. Alkaptonuria-associated aortic stenosis.

    Science.gov (United States)

    Lok, Zoe S Y; Goldstein, Jacob; Smith, Julian A

    2013-07-01

    Alkaptonuria is an autosomal recessive disorder of tyrosine metabolism, which results in accumulation of unmetabolized homogentisic acid and its oxidized product in various tissues, including the heart. Cardiovascular involvement is a rare but serious complication of the disease. We present two patients who have undergone successful aortic valve replacement for alkaptonuria-associated aortic stenosis along with a review of the literature. © 2013 Wiley Periodicals, Inc.

  7. Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?

    International Nuclear Information System (INIS)

    Baumueller, Stephan; Nguyen, Thi Dan Linh; Goetti, Robert Paul; Lachat, Mario; Seifert, Burkhardt; Pfammatter, Thomas; Frauenfelder, Thomas

    2011-01-01

    Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 ± 7.5 years, range 51–88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular to the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.

  8. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre...

  9. Impact of top end anastomosis design on patency and flow stability in coronary artery bypass grafting.

    Science.gov (United States)

    Koyama, Sachi; Kitamura, Tadashi; Itatani, Keiichi; Yamamoto, Tadashi; Miyazaki, Shohei; Oka, Norihiko; Nakashima, Kouki; Horai, Tetsuya; Ono, Minoru; Miyaji, Kagami

    2016-05-01

    For coronary artery bypass grafting (CABG), free grafts such as a saphenous vein or radial artery are often used for grafts to the lateral and posterior walls. However, the relationship between top-end anastomosis design and long-term patency remains unknown. Because coronary artery blood flow is dominant during diastole, top-end anastomosis may work better if the graft is directed towards the apex, whereas the shortest graft pathway appears to be most efficient. Using computational fluid dynamic models, we evaluated the hemodynamic variables that were affected by the angle of the top-end anastomosis. We created three-dimensional geometries of the aortic root with coronary arteries that involved 75 % stenosis in the obtuse marginal and postero-lateral branches. Two bypass models under vasodilator administration were created: in a"Model A", the top-end anastomosis is parallel to the long axis of the ascending aorta and the graft passed over the conus directed towards the apex; in a "Model B", the top-end anastomosis is directed toward the shortest pathway, and form near the right angles to the long axis of the ascending aorta. Wall shear stress (WSS) and its fluctuation, an oscillatory shear index (OSI) were evaluated to predict fibrosis progression at the anastomosis site and graft flow. Graft flow was 197.3 ml/min and 207.3 ml/min in the "Model A" and "Model B", respectively. The minimal WSS value inside the graft with the "Model A" and "Model B" was 0.53 Pa and 4.09 Pa, respectively, and the OSI value was 0.46 and 0.04, respectively. The top-end anastomosis of a free graft should be directed vertically towards the aorta to achieve the shortest graft pathway to maintain a high graft flow rate and to avoid the risks of endothelial fibrosis and plaque progression over the long-term after CABG.

  10. Combined open proximal and stent-graft distal repair for distal arch aneurysms: an alternative to total debranching.

    Science.gov (United States)

    Zierer, Andreas; Sanchez, Luis A; Moon, Marc R

    2009-07-01

    We present herein a novel, combined, simultaneous open proximal and stent-graft distal repair for complex distal aortic arch aneurysms involving the descending aorta. In the first surgical step, the transverse arch is opened during selective antegrade cerebral perfusion, and a Dacron graft (DuPont, Wilmington, DE) is positioned down the descending aorta in an elephant trunk-like fashion with its proximal free margin sutured circumferentially to the aorta just distal to the left subclavian or left common carotid artery. With the graft serving as the new proximal landing zone, subsequent endovascular repair is performed antegrade during rewarming through the ascending aorta.

  11. Hybrid treatment of a true thyreocervical trunk aneurysm in a patient with Type B aortic dissection

    Directory of Open Access Journals (Sweden)

    Nikolaos G Baikoussis

    2016-01-01

    Full Text Available We would like to describe a case with a complex aortic disease treated in hybrid fashion. We present an interesting case of a 65-year-old man with a medical history of hypertension, hyperlipidemia, and coronary artery disease percutaneously treated. An acute Type B aortic dissection occurred and treated with the implantation of a stent-graft which occluded the left subclavian artery due to its extension to the aortic arch. This event required a carotid-subclavian artery bypass due to ischemia of the left arm. An aneurysm in the innominate artery also detected, was treated with another stent-graft implantation 3 months later. At 5-year follow-up, an aneurysm of the thyreocervical trunk was found while the stent-graft of the aorta was well-tolerated without endoleak and the carotid-subclavian graft was patent. The aneurysm was asymptomatic but considering the risk of spontaneous rupture of an aneurysm of this size, elective surgery was indicated. Because the aneurysm was very close to the brachiocephalic bifurcation, open surgical repair would require a sternotomy. The right common carotid artery and right subclavian artery were exposed. The thyrocervical trunk, right internal mammary artery and right vertebral artery were occluded by ligations to isolate the aneurysm. An 8-mm Dacron graft was anastomosed end-to-end to the distal part of subclavian artery. We would like through this case, discuss the role of the hybrid cardiovascular surgery to minimize the postoperative complications in complex cardiovascular pathology. We also discuss the international bibliography about the thyreocervical trunk aneurysm and the treatment options.

  12. Results of aortic root reimplantation in patients with ascending aortic aneurysm and concomitant aortic insufficiency

    Directory of Open Access Journals (Sweden)

    А. М. Чернявский

    2016-01-01

    Full Text Available Objective. The research was designed to evaluate the results of valve-sparing operations: aortic root reimplantation versus aortic valve reimplantation when repairing an ascending aortic aneurysm with concomitant aortic insufficiency.Methods. Within a blind prospective randomized study conducted over a period from 2011 to 2015, 64 patients underwent aortic valve-sparing surgery. The inclusion criteria were the presence of an aortic aneurysm of the ascending aorta exceeding 4.5 cm and concomitant aortic insufficiency. All patients were divided into two groups: FS-group, aortic root reimplantation (modified Florida Sleeve technique (n = 32 and D-group, aortic valve reimplantation (David procedure (n = 32. The average age of patients was 57±13 (23–73 years in the FS-group and 55±11 (15–72 years in the D-group (p = 0.54. Both groups had 78% of males (p>0.99. A Marfan syndrome was identified in 6% and 9% in the FS-group and D-group respectively (p>0.99. Mean diameter of the sinuses of Valsalva was 51±7 mm and 56±10 mm (p = 0.09, aortic insufficiency 2.6±0.7 and 2.8±0.8 (p = 0.15 in the FS-group and D-group respectively. In the FS-group and D-group LVEDD amounted to 5.5±0.7 mm and 5.9±1.0 mm (p = 0.09 respectively. All patients took echocardiography in the preoperative, postoperative and follow-up periods.Results. In the long-term period, the degree of aortic regurgitation was 1.2±0.1 in the FS-group and 1.3±0.6 in the D-group (p = 0.72. LVEDD was 123±23 mm in the FS-group and 139.6±80 mm in the D-group at follow-up (p = 0.77. There were no statistically significant differences in the analysis of complications. Overall 30-day in-hospital mortality was 7.8%. There were 2 (6.3% deaths in the FS-group and 3 (9.4% in the D-group (p = 0.5.Late mortality was 6.3% in the FS-group and 3.1% in the D-group (p>0.99. Cumulative survival at 4 years was 84.3% and 84.8% in the FS-group and the D-group respectively (p = 0.94. Cumulative freedom from

  13. Evolving Practice Trends of Aortic Root Surgery in North America.

    Science.gov (United States)

    Caceres, Manuel; Ma, Yicheng; Rankin, J Scott; Saha-Chaudhuri, Paramita; Gammie, James S; Suri, Rakesh M; Thourani, Vinod H; Englum, Brian R; Esmailian, Fardad; Czer, Lawrence S; Puskas, John D; Svensson, Lars G

    2014-08-19

    Aortic-valve sparing (AVS) techniques have emerged as alternatives to composite graft-valve replacement (CVR) for treatment of aortic root aneurysm. This study analyzed recent practice trends of aortic root surgery using the Society of Thoracic Surgeons database. From January 2000 through June 2011, 31,747, Overall patients received AVS (n=3,585/31,747; 11.3%) or CVR (n=28,162/31,747; 88.7%). A High-Risk Subgroup was defined as: age >75 years, endocarditis, aortic stenosis, dialysis, multi-valve surgery, valve reoperation, or emergency/salvage status, and high-risk patients were less likely to receive AVS (n=20,356/31,747 [64.1%]; 6% AVS; unadjusted operative mortality 10.5% AVS and 11.7% CVR). The remaining patients comprised a Low-Risk Subgroup, in which AVS was more common (n=11,388/31,747 [35.9%]; 21% AVS; unadjusted operative mortality 1.4% AVS and 3.1% CVR). Procedural changes over 3 equal time periods (P1-P2-P3) were evaluated by Cochran-Armitage trends analysis. Compared to AVS, Overall CVR patients had worse baseline risk profiles and higher unadjusted operative mortality. In High-Risk patients, AVS mortality was comparable to CVR (10.5% vs 11.7%, p=0.19), but AVS mortality was lower in the Low-Risk group (1.4% vs 3%, pAVS percentages and trend p-values were: High-Risk (6%/6%/7%, p=0.26) and Low-Risk (12%/21%/25%, pAVS increased over time in Low-Risk patients while bioprostheses increased in CVR. Favorable outcomes support the trend toward further expansion of AVS. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Value and limitations of chimney grafts to treat arch lesions.

    Science.gov (United States)

    Mangialardi, N; Ronchey, S; Malaj, A; Fazzini, S; Alberti, V; Ardita, V; Orrico, M; Lachat, M

    2015-08-01

    The endovascular debranching with chimney stents provides a minimally invasive alternative to open surgery with readily available devices and has extended the option of endoluminal therapy into the realm of the aortic arch. But a critical observation at the use of this technique at the aortic arch is important and necessary because of the lack of long-term results and long term patency of the stents. Our study aims to review the results of chimney grafts to treat arch lesions. A systematic health database search was performed in December 2014 according to the Prisma Guidelines. Papers were sought through a meticulous search of the MEDLINE database (National Library of Medicine, Bethesda, MA) using the Pubmed search engine. Twenty-two articles were eligible for detailed analysis and data extraction. A total of 182 patients underwent chimney techniques during TEVAR (Thoracic Endovascular Aneurysm Repair). A total of 217 chimney grafts were implanted: 36 to the IA, 1 to the RCCA, 91 to the LCCA and 89 to the LSA. The type of stent-graft used for TEVAR was described in 132 patients. The type and name of chimney graft was described in 126 patients. In 53 patients information was limited to the type. Primary technical success, defined as a complete chimney procedure was achieved in 171 patients (98%). In 8 patients it was not clearly reported. The overall stroke rate was 5.3%. The overall endoleak rate, in those papers were it was clearly reported, was 18.4% (31 patients); 23(13,6%) patients developed a type IA endoleak, 1 patient (0.6%) developed type IB endoleak and 7 patients (4.1%) developed a type II endoleak The total endovascular aortic arch debranching technique represent a good option to treat high-risk patients, because it dramatically reduces the aggressiveness of the procedure in the arch. Many concerns are still present, mainly related to durability and material interaction during time. Long-term follow-up is exceptionally important in light of the

  15. Morphological risk factors of stroke during thoracic endovascular aortic repair.

    Science.gov (United States)

    Kotelis, Drosos; Bischoff, Moritz S; Jobst, Bertram; von Tengg-Kobligk, Hendrik; Hinz, Ulf; Geisbüsch, Philipp; Böckler, Dittmar

    2012-12-01

    This study aims to identify independent factors correlating to an increased risk of perioperative stroke during thoracic endovascular aortic repair (TEVAR). A prospective maintained TEVAR database, medical records, and imaging studies of 300 patients (205 men; median age of all, 66 years, range 21-89), who underwent TEVAR between March 1997 and February 2011, were reviewed. Preoperative CT data sets were reviewed by two experienced radiologists with focus on the atheroma burden in the aortic arch (grade I, normal, to grade V, ulcerated or pedunculated atheroma). Aortic arch geometry (arch types I-III) was documented. Further parameters included in the univariate analysis were age, gender, urgency of repair, duration of procedure, adenosine-induced cardiac arrest or rapid pacing, proximal landing zone, left subclavian artery (LSA) coverage, and number of stent grafts. Multivariate logistic regression analysis was performed to assess the independent correlations of potential risk factors. Atherosclerotic aneurysm was the most common pathology (44%). One hundred and fifty-four of our patients (51%) were treated under urgent or emergent conditions. Seventeen percent of all patients had significant arch atheroma (grade IV or V), and 43% had a steep type III aortic arch. The perioperative stroke was 4% (12 patients; median age, 73 years, range 31-78). Two strokes were lethal (0.7%). All strokes were classified as embolic based on imaging characteristics. In eight patients, strokes were located in the left cerebral hemisphere (seven of them in the anterior and one in the posterior circulation). Four stroke patients (one in the left posterior circulation) underwent LSA coverage without revascularization. Three stroke patients had severe arch atheroma grade V. Five patients suffering stroke were recognized to have a type III aortic arch. Strokes were equally distributed between zones 0-2 vs. 3-4 (n = 6 each, 5 vs. 3.3%). The highest incidence was found in zone 1 (11

  16. Wall stress on ascending thoracic aortic aneurysms with bicuspid compared with tricuspid aortic valve.

    Science.gov (United States)

    Xuan, Yue; Wang, Zhongjie; Liu, Raymond; Haraldsson, Henrik; Hope, Michael D; Saloner, David A; Guccione, Julius M; Ge, Liang; Tseng, Elaine

    2018-03-08

    Guidelines for repair of bicuspid aortic valve-associated ascending thoracic aortic aneurysms have been changing, most recently to the same criteria as tricuspid aortic valve-ascending thoracic aortic aneurysms. Rupture/dissection occurs when wall stress exceeds wall strength. Recent studies suggest similar strength of bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms; thus, comparative wall stress may better predict dissection in bicuspid aortic valve versus tricuspid aortic valve-ascending thoracic aortic aneurysms. Our aim was to determine whether bicuspid aortic valve-ascending thoracic aortic aneurysms had higher wall stresses than their tricuspid aortic valve counterparts. Patients with bicuspid aortic valve- and tricuspid aortic valve-ascending thoracic aortic aneurysms (bicuspid aortic valve = 17, tricuspid aortic valve = 19) greater than 4.5 cm underwent electrocardiogram-gated computed tomography angiography. Patient-specific 3-dimensional geometry was reconstructed and loaded to systemic pressure after accounting for prestress geometry. Finite element analyses were performed using the LS-DYNA solver (LSTC Inc, Livermore, Calif) with user-defined fiber-embedded material model to determine ascending thoracic aortic aneurysm wall stress. Bicuspid aortic valve-ascending thoracic aortic aneurysms 99th-percentile longitudinal stresses were 280 kPa versus 242 kPa (P = .028) for tricuspid aortic valve-ascending thoracic aortic aneurysms in systole. These stresses did not correlate to diameter for bicuspid aortic valve-ascending thoracic aortic aneurysms (r = -0.004) but had better correlation to tricuspid aortic valve-ascending thoracic aortic aneurysms diameter (r = 0.677). Longitudinal stresses on sinotubular junction were significantly higher in bicuspid aortic valve-ascending thoracic aortic aneurysms than in tricuspid aortic valve-ascending thoracic aortic aneurysms (405 vs 329 kPa, P = .023). Bicuspid

  17. Compression of the right coronary artery by an aortic pseudoaneurysm after infective endocarditis: an unusual case of myocardial ischemia.

    Science.gov (United States)

    Lacalzada-Almeida, Juan; De la Rosa-Hernández, Alejandro; Izquierdo-Gómez, María Manuela; García-Niebla, Javier; Hernández-Betancor, Iván; Bonilla-Arjona, Juan Alfonso; Barragán-Acea, Antonio; Laynez-Cerdeña, Ignacio

    2018-01-01

    A 61-year-old male with a prosthetic St Jude aortic valve size 24 presented with heart failure symptoms and minimal-effort angina. Eleven months earlier, the patient had undergone cardiac surgery because of an aortic root dilatation and bicuspid aortic valve with severe regurgitation secondary to infectious endocarditis by Coxiela burnetii and coronary artery disease in the left circumflex coronary artery. Then, a prosthesis valve and a saphenous bypass graft to the left circumflex coronary artery were placed. The patient was admitted to the Cardiology Department of Hospital Universitario de Canarias, Tenerife, Spain and a transthoracic echocardiography was performed that showed severe paraprosthetic aortic regurgitation and an aortic pseudoaneurysm. The 64-slice multidetector computed tomography confirmed the pseudoaneurysm, originating from the right sinus of Valsalva, with a compression of the native right coronary artery and a normal saphenous bypass graft. On the basis of these findings, we performed surgical treatment with a favorable postoperative evolution. In our case, results from complementary cardiac imaging techniques were crucial for patient management. The multidetector computed tomography allowed for a confident diagnosis of an unusual mechanism of coronary ischemia.

  18. Bovine aortic arch: A novel association with thoracic aortic dilation

    International Nuclear Information System (INIS)

    Malone, C.D.; Urbania, T.H.; Crook, S.E.S.; Hope, M.D.

    2012-01-01

    Aim: To investigate whether there is a link between bovine arch and thoracic aortic aneurysm. Materials and methods: Computed tomography (CT) and magnetic resonance imaging (MRI) images of the thorax of 191 patients with dilated thoracic aortas and 391 consecutive, unselected patients as controls were retrospectively reviewed. Bovine arch was considered present if either a shared origin of the left common carotid and innominate arteries or an origin of the left common carotid from the innominate artery was identified. A chi-square test was used to evaluate the significance of differences between subgroups. Results: A trend towards increased prevalence of bovine arch was seen in patients with dilated aortas (26.2%) compared to controls (20.5%, p = 0.12). The association was statistically significant in patients over 70 years old (31.9%, p = 0.019) and when dilation involved the aortic arch (47.6%, p = 0.003). Conclusions: An association between bovine arch and aortic dilation is seen in older patients, and when dilation involves the aortic arch. Bovine arch should be considered a potential risk factor for thoracic aortic aneurysm.

  19. Left Ventricular Assist Device Implantation with Concomitant Aortic Valve and Ascending Aortic Replacement.

    Science.gov (United States)

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-01-01

    Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed.

  20. Dynamics of the aortic annulus in 4D CT angiography for transcatheter aortic valve implantation patients

    NARCIS (Netherlands)

    Elattar, Mustafa A.; Vink, Leon W.; van Mourik, Martijn S.; Baan, Jan; Vanbavel, Ed T.; Planken, R. Nils; Marquering, Henk A.

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) is a well-established treatment for patients with severe aortic valve stenosis. This procedure requires pre-operative planning by assessment of aortic dimensions on CT Angiography (CTA). It is well-known that the aortic root dimensions vary over the

  1. Early and late results of graft replacement for dissecting aneurysm of thoracoabdominal aorta in patients with Marfan syndrome.

    Science.gov (United States)

    Omura, Atsushi; Tanaka, Akiko; Miyahara, Shunsuke; Sakamoto, Toshihito; Nomura, Yoshikatsu; Inoue, Takeshi; Oka, Takanori; Minami, Hitoshi; Okada, Kenji; Okita, Yutaka

    2012-09-01

    When treating dissecting aneurysm of the thoracoabdominal aorta surgically in patients with Marfan syndrome, we have usually performed graft replacement- including the entire thoracoabdominal aorta and reconstruction of all visceral branches, even if dilatation is mild in some segments-to avoid further aortic operations in the follow-up period. From October 1999 through July 2011, 20 consecutive patients with Marfan syndrome underwent repair of dissecting aneurysm of the thoracoabdominal aorta (median age, 45 years; range, 19-65 years). All patients underwent surgical intervention with cerebrospinal fluid (CSF) drainage and distal aortic and selective organ perfusion. Deep hypothermia was used in 13 patients for spinal cord protection. No in-hospital mortality was observed. One patient had temporary spinal cord ischemia but was fully recovered by discharge. Other complications included exploration for bleeding (n=1), prolonged ventilation (n=1), and graft infection (n=1). At a mean follow-up of 54 months (range, 9-129 months), 1 patient had died of interstitial pneumonia at 38 months postoperatively. Survival at 8% years was 91.2±9.0%. Two patients required additional aortic procedures (total arch replacement and aortic valve-sparing surgery). Actuarial rate of freedom from aortic operations at 8 years was 83.9%±10.5%, but no patient needed required repeated thoracotomy for an aortic procedure. Neither false nor patch aneurysms were observed using computed tomography (CT) during follow-up surveillance. Graft replacement for dissecting aneurysm of the thoracoabdominal aorta in Marfan syndrome offers good early and long-term results. We believe total aortic replacement including the entire thoracoabdominal aorta and reconstruction of all visceral arteries should be recommended for selected patients with Marfan syndrome. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Deep Venous Thrombosis of the Leg, Associated with Agenesis of the Infrarenal Inferior Vena Cava and Hypoplastic Left Kidney (KILT Syndrome in a 14-Year-Old Child

    Directory of Open Access Journals (Sweden)

    Sakshi Bami

    2015-01-01

    Full Text Available Agenesis of the inferior vena cava (IVC is a rare anomaly which can be identified as incidental finding or can be associated with iliofemoral vein thrombosis. IVC agenesis has a known association with renal anomalies which are mainly confined to the right kidney. We describe a case of a 14-year-old male who presented with left leg swelling and pain. Ultrasonography confirmed the presence of left leg deep vein thrombosis (DVT. No underlying hematologic risk factors were identified. A CT scan was obtained which demonstrated absent infrarenal IVC and extensive thrombosis in the left deep venous system and development of collateral venous flow into the azygous/hemiazygous system, with extension of thrombus into paraspinal collaterals. An additional finding in the patient was an atrophic left kidney and stenosis of an accessory left renal artery. Agenesis of the IVC should be considered in a young patient presenting with lower extremity DVT, especially in patients with no risk factors for thrombosis. As agenesis of the IVC cannot be corrected, one should be aware that there is a lifelong risk of lower extremity DVT.

  3. [Effect of native aortic valve sparing aortic root reconstruction surgery on short- and long-term prognosis in Marfan syndrome patients:a meta-analysis].

    Science.gov (United States)

    Hu, Rui; Wang, Zhiwei; Hu, Xiaoping; Wu, Hongbing; Zhou, Zhen

    2014-05-01

    This meta-analysis was performed to analyze the effect of preserving the native aortic valve on short- and long-term prognosis post aortic root reconstruction surgery for patients with Marfan syndrome. Database including Pubmed,Embase, Cochrane library, CNKI, Wanfang,VIP and CBM were searched to collect studies comparing clinical results of valve sparing surgery with composite valve graft surgery for patients with Marfan syndrome. Study quality was assessed by Newcastle-Ottawa Scale and publication bias was assessed by visual inspection of the funnel plot together with Egger test. Clinical outcomes data was extracted from the manuscripts and analyzed with Revman 5.0 supplied by Cochrane collaboration. Seven clinical trials with 690 patients were included. Meta- analysis demonstrated that valve sparing surgery was associated with a lower incidence of re-exploration (RR = 0.51, 95%CI:0.29- 0.90, P 0.05). Valve sparing aortic root reconstruction surgery is a superior procedure to composite valve graft surgery in term of improving the short- and long-term prognosis for patients with Marfan syndrome.

  4. Bicuspid Aortic Valve Disease: A Comprehensive Review

    OpenAIRE

    Mordi, Ify; Tzemos, Nikolaos

    2012-01-01

    Bicuspid aortic valve is the commonest congenital cardiac abnormality in the general population. This paper article will discuss our current knowledge of the anatomy, pathophysiology, genetics, and clinical aspects of bicuspid aortic valve disease.

  5. Aortic compliance in patients with aortic regurgitation. Evaluation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murai, Sachiko; Hamada, Seiki; Ueguchi, Takashi

    2005-01-01

    The purpose of this study was to assess by means of cine magnetic resonance imaging (MRI) aortic compliance before and after aortic valve replacement (AVR with SJM (St. Jude Medical, St paul, MN) valve) in patients with aortic regurgitation (AR). Two groups (healthy controls and patients with severe isolated AR) of 10 subjects each were included in this study. Cine MRI was performed at three locations of the aorta, and aortic compliance was calculated by dividing the maximum change in the aortic area by pulse pressure. Cine MRI is useful to assess abnormalities of aortic compliance in patients with AR. Compared with the control group, aortic compliance in the AR group was significantly less in the ascending aorta (p<0.05), decreasing in order of aortic location. After AVR, aortic compliance improved for all locations. Cine MRI enables assessment of aortic biophysical properties such as a compliance for evaluating the progression of AR and the efficacy of treatment. (author)

  6. Abdominal aortic feminism.

    Science.gov (United States)

    Mortimer, Alice Emily

    2014-11-14

    A 79-year-old woman presented to a private medical practice 2 years previously for an elective ultrasound screening scan. This imaging provided the evidence for a diagnosis of an abdominal aortic aneurysm (AAA) to be made. Despite having a number of recognised risk factors for an AAA, her general practitioner at the time did not follow the guidance set out by the private medical professional, that is, to refer the patient to a vascular specialist to be entered into a surveillance programme and surgically evaluated. The patient became symptomatic with her AAA, was admitted to hospital and found to have a tender, symptomatic, 6 cm leaking AAA. She consented for an emergency open AAA repair within a few hours of being admitted to hospital, despite the 50% perioperative mortality risk. The patient spent 4 days in intensive care where she recovered well. She was discharged after a 12 day hospital stay but unfortunately passed away shortly after her discharge from a previously undiagnosed gastric cancer. 2014 BMJ Publishing Group Ltd.

  7. Aortic atresia with normal sized left ventricle

    OpenAIRE

    Priya Jagia; Arun Sharma; Saurabh K Gupta; Munish Guleria

    2016-01-01

    Aortic atresia with an associated ventricular septal defect and adequate sized left ventricle is extremely rare. We present two cases in which an alternate diagnosis was suggested on echocardiography because the hypoplastic aortic trunk was missed due to its small caliber. The final diagnosis was, however, clinched on dual source computed tomography, which not only showed the thin aortic trunk but also clearly depicted the coronary artery origins from the hypoplastic aortic root. To the best ...

  8. A History of Thoracic Aortic Surgery.

    Science.gov (United States)

    McFadden, Paul Michael; Wiggins, Luke M; Boys, Joshua A

    2017-08-01

    Ancient historical texts describe the presence of aortic pathology conditions, although the surgical treatment of thoracic aortic disease remained insurmountable until the 19th century. Surgical treatment of thoracic aortic disease then progressed along with advances in surgical technique, conduit production, cardiopulmonary bypass, and endovascular technology. Despite radical advances in aortic surgery, principles established by surgical pioneers of the 19th century hold firm to this day. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. [Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms].

    Science.gov (United States)

    Pitton, M B; Schmiedt, W; Neufang, A; Düber, C; Thelen, M

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings.

  10. Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Pitton, M.B.; Thelen, M.; Schmiedt, W.; Neufang, A.; Dueber, C.

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings. (orig.)

  11. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2017-04-26

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  12. Thoracic Endovascular Aortic Repair (TEVAR) in Proximal (Type A) Aortic Dissection: Ready for a Broader Application?

    OpenAIRE

    Nienaber, Christoph A.; Sakalihasan, Natzi; Clough, Rachel E.; Aboukoura, Mohamed; Mancuso, Enrico; Yeh, James S.M.; Defraigne, Jean-Olivier; Cheshire, Nick; Rosendahl, Ulrich Peter; Quarto, Cesare; Pepper, John

    2016-01-01

    ObjectiveThoracic endovascular aortic repair (TEVAR) has demonstrated encouraging results and is gaining increasing acceptance as a treatment option for aortic aneurysms and dissections. Yet, its role in managing proximal aortic pathologies is unknown - this is important because in proximal (Stanford type A) aortic dissections, 10-30% are not accepted for surgery, and 30-50% are technically amenable for TEVAR. We describe our case series of type A aortic dissections treated using TEVAR.Method...

  13. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  14. Strategy for acute type IIIb aortic dissection associated with abdominal-organ malperfusion

    International Nuclear Information System (INIS)

    Ozawa, Masamichi; Uchida, Naomichi; Shibamura, Hidenori; Iwako, Hiroshi

    2006-01-01

    The aim of this study was to evaluate our results of treatment for acute type IIIb aortic dissection associated with malperfusion of abdominal organs, and to consider the therapeutic strategies. Between December 1997 and August 2005, 123 patients with acute type IIIb aortic dissection were treated at our hospital. Of those, 11 patients (8.9%) required emergency treatment for malperfusion of abdominal organ. In our hospital, the indication of emergency treatment for acute type IIIb aortic dissection was any symptom of acute abdomen plus insufficiency of visceral arterial circulation on computed tomography or angiography. All of the 11 patients (100%) had cul-de-sac of a false lumen, 8 (72.7%) had at least one symptom of acute abdomen, and 3 (27.3%) had metabolic acidosis before surgical treatment. In 7 patients of the ''true lumen stenosis type,'' 5 patients who were treated with open stent grafting are alive. The other two patients, who were treated with transluminally placed endovascular stent grafting (TPEG) or with superior mesenteric artery (SMA) bypass, died. Of the 2 ''visceral arterial dissection type'' patient, one was treated with transluminal stenting of the celiac artery and the other was treated with resection of the intestine and ileocolic artery bypass, and both are alive. Two ''mixed type'' patients who were treated with open stent grafting died. The mortality rate of this series was 36.4%. In conclusion, to improve the prognosis of acute type IIIb aortic dissection associated with malperfusion of abdominal organ, it is important that we obtain early diagnosis of organ ischemia caused by cul-de-sac of a false lumen and choose the correct treatment based on understanding of the mechanism of organ ischemia. (author)

  15. Arteriovenous shunt graft ulceration with sinus and graft epithelialization

    Directory of Open Access Journals (Sweden)

    Pooja Singhal

    2015-03-01

    Full Text Available Arteriovenous fistula and grafts are used as access sites for patients with chronic kidney disease and are prone for complications. Stent grafts are used to treat access site complications. We report a rare and unusual finding of epithelialization of the sinus tract and the lumen of a polytetrafluoroethylene graft, following ulceration of the overlying skin.

  16. Aortic atresia with normal sized left ventricle

    Directory of Open Access Journals (Sweden)

    Priya Jagia

    2016-01-01

    Full Text Available Aortic atresia with an associated ventricular septal defect and adequate sized left ventricle is extremely rare. We present two cases in which an alternate diagnosis was suggested on echocardiography because the hypoplastic aortic trunk was missed due to its small caliber. The final diagnosis was, however, clinched on dual source computed tomography, which not only showed the thin aortic trunk but also clearly depicted the coronary artery origins from the hypoplastic aortic root. To the best of our knowledge, use of multi-detector computed tomography in aortic atresia with well developed left ventricle has not been reported in literature till date.

  17. Anatomic changes of target vessels after fenestrated and branched aortic aneurysm repair.

    Science.gov (United States)

    Kalder, J; Keschenau, P; Tamm, M; Jalaie, H; Jacobs, M J; Greiner, A

    2014-04-01

    Objective of this study was to evaluate the anatomic changes of the stented target vessels after endovascular repair of complex aortic aneurysms. Between July 2011 and December 2013, 53 aortic aneurysms were treated in our department with fenestrated and branched stent-graft devices. Forty-two of these patients were pre- and postoperatively scanned with a high resolution computer tomography (CT) (Cook Zenith® fenestrated or branched, Australia Pty. Ltd., Brisbane, Australia: N.=19; AnacondaTM fenestrated, Vascutek, Glasgow, Scotland, UK: N.=23). The other 11 out of the 53 patients did not receive a CT scan, because of a pre-existing renal failure. In the CT scans we retrospectively evaluated the anatomic vessel deviation at the origin of the target vessel and the vessel shift distal to the stent. For the first measurement the CT scans were loaded into OsiriX MD®, and the pre- and postoperative angles of the target vessels were measured and subtracted. For matching, the CT-scans were normalized at vertebral body lumbar 2. The second measured angle was the maximal measured angle distal to the target vessel stent-graft. Altogether, 113 target vessels were stented (celiac trunk [CT] 15, superior mesenteric arteries [SMA] 26, renal arteries [RA] 72), with 97 balloon-expandable PTFE stents: 90 Atrium V12 (Maquet Getinge group, Hudson, NH, USA), 7 BeGrafts (Bentley InnoMed, Hechingen, Germany) and 16 self-expandable fluency PTFE stents (Bard, Karlsruhe, Germany). The mean anatomic deviation at the target vessel origin was 28±17.3 and the mean vessel shift distal to the stent was 36.3±18.8. There were no significant differences between the main device and the target vessel stent types. Fenestrated and branched stent-graft solutions for aortic aneurysm repair induce changes of the target vessel anatomy. We did not observe significant differences between the several devices.

  18. MMP-2 Isoforms in Aortic Tissue and Serum of Patients with Ascending Aortic Aneurysms and Aortic Root Aneurysms

    Science.gov (United States)

    Tscheuschler, Anke; Meffert, Philipp; Beyersdorf, Friedhelm; Heilmann, Claudia; Kocher, Nadja; Uffelmann, Xenia; Discher, Philipp; Siepe, Matthias; Kari, Fabian A.

    2016-01-01

    Objective The need for biological markers of aortic wall stress and risk of rupture or dissection of ascending aortic aneurysms is obvious. To date, wall stress cannot be related to a certain biological marker. We analyzed aortic tissue and serum for the presence of different MMP-2 isoforms to find a connection between serum and tissue MMP-2 and to evaluate the potential of different MMP-2 isoforms as markers of high wall stress. Methods Serum and aortic tissue from n = 24 patients and serum from n = 19 healthy controls was analyzed by ELISA and gelatin zymography. 24 patients had ascending aortic aneurysms, 10 of them also had aortic root aneurysms. Three patients had normally functioning valves, 12 had regurgitation alone, eight had regurgitation and stenosis and one had only stenosis. Patients had bicuspid and tricuspid aortic valves (9/15). Serum samples were taken preoperatively, and the aortic wall specimen collected during surgical aortic repair. Results Pro-MMP-2 was identified in all serum and tissue samples. Pro-MMP-2 was detected in all tissue and serum samples from patients with ascending aortic/aortic root aneurysms, irrespective of valve morphology or other clinical parameters and in serum from healthy controls. We also identified active MMP-2 in all tissue samples from patients with ascending aortic/aortic root aneurysms. None of the analyzed serum samples revealed signals relatable to active MMP-2. No correlation between aortic tissue total MMP-2 or tissue pro-MMP-2 or tissue active MMP-2 and serum MMP-2 was found and tissue MMP-2/pro-MMP-2/active MMP-2 did not correlate with aortic diameter. This evidence shows that pro-MMP-2 is the predominant MMP-2 species in serum of patients and healthy individuals and in aneurysmatic aortic tissue, irrespective of aortic valve configuration. Active MMP-2 species are either not released into systemic circulation or not detectable in serum. There is no reliable connection between aortic tissue—and serum MMP-2

  19. In vitro degradation and cell attachment studies of a new electrospun polymeric tubular graft.

    Science.gov (United States)

    Patel, Harsh N; Thai, Kevin N; Chowdhury, Sami; Singh, Raj; Vohra, Yogesh K; Thomas, Vinoy

    Electrospinning technique was utilized to engineer a small-diameter (id = 4 mm) tubular graft. The tubular graft was made from biocompatible and biodegradable polymers polycaprolactone (PCL) and poliglecaprone with 3:1 (PCL:PGC) ratio. Enzymatic degradation effect on the mechanical properties and fiber morphology in the presence of lipase enzyme were observed. Significant changes in tensile strength (1.86-1.49 MPa) and strain (245-205 %) were noticed after 1 month in vitro degradation. The fiber breakage was clearly evident through scanning electron microscopy (SEM) after 4 weeks in vitro degradation. Then, the graft was coated with a collagenous protein matrix to impart bioactivity. Human umbilical vein endothelial cells (HUVECs) and aortic artery smooth muscle cells (AoSMCs) attachment on the coated graft were observed in static condition. Further, HUVECs were seeded on the lumen surface of the grafts and exposed to laminar shear stress for 12 h to understand the cell attachment. The coated graft was aged in PBS solution (pH 7.3) at 37 °C for 1 month to understand the coating stability. Differential scanning calorimetry (DSC) and Fourier transform infrared spectroscopy (FTIR) suggested the erosion of the protein matrix from the coated graft under in vitro condition.

  20. Haemodynamics in axillobifemoral bypass grafts

    NARCIS (Netherlands)

    C.H. Wittens

    1992-01-01

    textabstractThis thesis is based on four publications on the subject of graft configuration and haemodynamics in axillobifemoral bypass grafts: 1. A clinical evaluation of 17 patients with axillobifemoral bypass graft operations, performed for various indications. Two important observations were

  1. Aortic Root Enlargement or Sutureless Valve Implantation?

    Directory of Open Access Journals (Sweden)

    Nikolaos G. Baikoussis

    2016-11-01

    Full Text Available Aortic valve replacement (AVR in patients with a small aortic annulus is a challenging issue. The importance of prosthesis–patient mismatch (PPM post aortic valve replacement (AVR is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively and keeping in mind that often some comorbidities are present in old patients with small aortic root, the Perceval S suturelles valve implantation could be a perfect solution. The Perceval sutureless bioprosthesis provides reasonable hemodynamic performance avoiding the PPM and providing the maximum of aortic orifice area. We would like to see in the near future the role of the aortic root enlargement techniques in the era of surgical implantation of the sutureless valve (SAVR and the transcatheter valve implantation (TAVI.

  2. Aortic valve function after bicuspidization of the unicuspid aortic valve.

    Science.gov (United States)

    Aicher, Diana; Bewarder, Moritz; Kindermann, Michael; Abdul-Khalique, Hashim; Schäfers, Hans-Joachim

    2013-05-01

    Unicuspid aortic valve (UAV) anatomy leads to dysfunction of the valve in young individuals. We introduced a reconstructive technique of bicuspidizing the UAV. Initially we copied the typical asymmetry of a normal bicuspid aortic valve (BAV) (I), later we created a symmetric BAV (II). This study compared the hemodynamic function of the two designs of a bicuspidized UAV. Aortic valve function was studied at rest and during exercise in 28 patients after repair of UAV (group I, n = 8; group II, n = 20). There were no differences among the groups I and II with respect to gender, age, body size, or weight. All patients were in New York Heart Association class I. Six healthy adults served as control individuals. All patients were studied with transthoracic echocardiography between 4 and 65 months postoperatively. Systolic gradients were assessed by continuous wave Doppler while patients were at rest and exercising on a bicycle ergometer. Aortic regurgitation was grade I or less in all patients. Resting gradients were significantly elevated in group I compared with group II and control individuals (group I, peak 33.8 ± 7.8 mm Hg; mean 19.1 ± 5.4 mm Hg; group II, peak 15.8 ± 5.4, mean 8.2 ± 2.8 mm Hg; control individuals, peak 6.0 ± 1.6, mean 3.2 ± 0.8 mm Hg; p competence. A symmetric repair design leads to improved systolic aortic valve function at rest and during exercise. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Reduction of indium-111 platelet deposition on Dacron vascular grafts in humans by aspirin plus dipyridamole

    International Nuclear Information System (INIS)

    Stratton, J.R.; Ritchie, J.L.

    1986-01-01

    Aspirin plus dipyridamole reduces platelet accumulation on short-term Dacron vascular grafts in man. To determine whether drug inhibition of platelet deposition is sustained on older grafts, we studied 18 men aged 41 to 87 years who had Dacron aortic bifurcation grafts in place a mean of 43.4 months (range 9.8 to 121.0) before and during short-term therapy with aspirin (325 mg tid) plus dipyridamole (75 mg tid). During both the baseline and drug studies, indium-111 ( 111 In) platelet deposition was quantitated by two techniques, standard planar imaging performed at 24, 48, and 72 hr after injection of platelets and single photon emission computed tomographic imaging performed at 24 and 72 hr after injection. All analyses were performed in a blinded fashion. On both the planar and tomographic images, platelet accumulation on the graft was quantitated by a graft/blood ratio that compared activity in the graft to simultaneously collected whole blood 111 In platelet activity. Aspirin plus dipyridamole reduced the tomographic graft/blood ratio at 24 hr (20.6 +/- 3.5 vs 17.3 +/- 2.5) (+/-SEM) and at 72 hr (29.0 +/- 4.8 vs 25.0 +/- 4.1) after injection of platelets (p = .02). Dacron vascular grafts. Similarly, the planar graft/blood ratio was reduced at 24 hr (2.7 +/- 0.5 vs 2.4 +/- 0.5), 48 hr (3.7 +/- 0.9 vs 3.1 +/- 0.7), and 72 hr (4.0 +/- 0.9 vs 3.6 +/- 0.8) (p = .04). We conclude that aspirin (325 mg tid) plus dipyridamole (75 mg tid) reduces platelet accumulation on long-term Dacron vascular grafts

  4. Primary renal graft thrombosis

    NARCIS (Netherlands)

    Bakir, N; Sluiter, WJ; Ploeg, RJ; van Son, WJ; Tegzess, Adam

    Background. Renal allograft thrombosis is a serious complication of kidney transplantation that ultimately leads to graft loss. Its association with acute and hyperacute rejection is well documented; however, in a large proportion of patients the precise cause remains obscure. The exact incidence

  5. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  6. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  7. Statins for aortic valve stenosis.

    Science.gov (United States)

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  8. Long-term results of aortic valve replacement with Edwards Prima Plus stentless bioprosthesis: eleven years' follow up.

    Science.gov (United States)

    Auriemma, Stefano; D'Onofrio, Augusto; Brunelli, Massimo; Magagna, Paolo; Paccanaro, Mariemma; Rulfo, Fanny; Fabbri, Alessandro

    2006-09-01

    The Edwards Lifesciences Prima Plus stentless valve (ELSV) is a bioprosthesis manufactured from a porcine aortic root. The study aim was to evaluate late clinical outcomes after aortic valve replacement (AVR) with ELSV implanted as a miniroot in patients with aortic valve disease. Between 1993 and 2004, 318 patients (232 males, 86 females; mean age 69 +/- 9 years; range: 37-83 years) underwent AVR with the ELSV. Preoperatively, 102 patients (32%), 162 (51%) and 54 (17%) were in NYHA classes I/II, III and IV, respectively. Aortic stenosis, aortic regurgitation and combined lesions were present in 124 patients (39%), 114 (36%) and 41 (13%), respectively. Twenty patients (6%) were referred for an acute aortic dissection, 20 (6%) for an aortic root aneurysm, and 139 (44%) had an associated aneurysmal dilatation of the ascending aorta. The ascending aorta was replaced in 159 patients (50%); aortic arch replacement was required in 10 (3%). Coronary artery bypass graft was performed in 86 patients (27%). The follow up was based on clinical data. Operative mortality was 5% (n = 17). There were 49 late deaths (5.2%/pt-yr). Valve-related mortality occurred in 10 patients (1%/pt-yr). Actuarial survival at five and 10 years was 78% and 33%, respectively. Actuarial freedom from valve reoperation and structural valve deterioration at 10 years were 100% and 64%. Actuarial freedom from embolic events and endocarditis at 10 years were 84% and 81%, respectively. The ELSV, when implanted as a miniroot, provided good early and long-term results in terms of survival and freedom from major complications.

  9. Application of rapid artificial cardiac pacing in thoracic endovascular aortic repair in aged patients

    Directory of Open Access Journals (Sweden)

    Chen J

    2013-12-01

    Full Text Available Jun Chen,1,* Wenhui Huang,2,* Songyuan Luo,2,* Dahao Yang,1 Zhengrong Xu,1 Jianfang Luo21Department of Angiocardiopathy, Affiliated Baoan Hospital of Southern Medical University, Shenzhen City, People's Republic of China; 2Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, People's Republic of China*These authors contributed equally to this workObjective: To compare the safety, efficacy, and impact on stent graft positioning between rapid artificial cardiac pacing (RACP, induced hypotension and sodium nitroprusside (SNP induced hypotension during thoracic endovascular aortic repair (TEVAR for Stanford B aortic dissection.Methods: One hundred and sixty-eight patients, who were diagnosed with Stanford B aortic dissection and who underwent selective TEVAR in Guangdong General Hospital and the People's Hospital of Baoan District, Shenzhen, People's Republic of China, were enrolled in this study. Patients were randomly divided into a RACP group (n=77 and a SNP group (n=91. During localization and deployment of the stent graft, hypotension was induced by RACP or intravenous SNP, according to randomization. Hemodynamics, landing precision (deviation from planned placement site, duration of procedure, renal function, neurocognitive function, and incidence of endoleaks and paraplegia/hemiplegia were compared. Except for methods of inducing hypotension, TEVAR was performed according to the same protocol in each group.Results: RACP was successfully performed in all patients assigned to the RACP group. Compared with the SNP group, blood pressure was significantly lower (43±5 versus 81±6 mmHg, P=0.003 and the restoration time of blood pressure and the operation duration were significantly shorter (7±2 versus 451±87 seconds, P<0.001; 87±15 versus 106±18 minutes, P<0.001, respectively in the RACP group. Stent graft localization/deployment was more precise in the RACP

  10. Aortic Root Surgery in Marfan Syndrome: Medium-Term Outcome in a Single-Center Experience.

    Science.gov (United States)

    Attenhofer Jost, Christine H; Connolly, Heidi M; Scott, Christopher G; Ammash, Naser M; Bowen, Juan M; Schaff, Hartzell V

    2017-01-01

    The study aim was to analyze the authors' experience with aortic root surgery in Marfan syndrome (MFS), and to expand the surgical outcome data of patients meeting the Ghent criteria (Marfan registry). Analyses were performed of data acquired from MFS patients (who met the Ghent criteria), including an aortic root surgery and Kaplan-Meier survival. Between April 2004 and February 2012, a total of 59 MFS patients (mean age at surgery 36 ± 13 years) underwent 67 operations for aortic root aneurysm (n = 52), aortic valve (AV) regurgitation (n = 15), acute aortic dissection (n = 2), and/or mitral valve (MV) regurgitation resulting from MV prolapse (n = 7). Of 59 initial operations, 21 (36%) involved AV-replacing root surgery, 38 (64%) AV-sparing root surgery, seven (12%) aortic arch or hemi-arch repair, and five (8%) simultaneous MV surgery. There were no early mortalities. The mean follow up was 6.8 ± 1.2 years, with five deaths (8%) and a relatively low reoperation rate (10 reoperations in nine patients; 14%). Seven reoperations involved AV or aortic root surgery (including four for AV regurgitation following failed AV-sparing surgery), two MV repair/replacements, and one coronary artery bypass graft. Eight patients (21%) with AV-sparing surgery had moderate/severe AV regurgitation at the last follow up before re-intervention. The mean five-year freedom from postoperative death was 91.2 ± 8.8%, from cardiac reoperation 86.3 ± 4.5%, and more-than-moderate AV regurgitation 90.3 ± 4.8%. Prophylactic aortic surgery in MFS patients with AV-replacing root or AV-sparing root surgery carries a low risk of operative morbidity and death when performed at an experienced center. AV-sparing root surgery increases the risk of AV regurgitation and, possibly, of re-intervention. Regular clinical follow up is important after any aortic root surgery in MFS patients, with a delineation of risk factors for AV regurgitation after AV rootsparing surgery.

  11. Neurological Complications Following Endoluminal Repair of Thoracic Aortic Disease

    International Nuclear Information System (INIS)

    Morales, J. P.; Taylor, P. R.; Bell, R. E.; Chan, Y. C.; Sabharwal, T.; Carrell, T. W. G.; Reidy, J. F.

    2007-01-01

    Open surgery for thoracic aortic disease is associated with significant morbidity and the reported rates for paraplegia and stroke are 3%-19% and 6%-11%, respectively. Spinal cord ischemia and stroke have also been reported following endoluminal repair. This study reviews the incidence of paraplegia and stroke in a series of 186 patients treated with thoracic stent grafts. From July 1997 to September 2006, 186 patients (125 men) underwent endoluminal repair of thoracic aortic pathology. Mean age was 71 years (range, 17-90 years). One hundred twenty-eight patients were treated electively and 58 patients had urgent procedures. Anesthesia was epidural in 131, general in 50, and local in 5 patients. Seven patients developed paraplegia (3.8%; two urgent and five elective). All occurred in-hospital apart from one associated with severe hypotension after a myocardial infarction at 3 weeks. Four of these recovered with cerebrospinal fluid (CSF) drainage. One patient with paraplegia died and two had permanent neurological deficit. The rate of permanent paraplegia and death was 1.6%. There were seven strokes (3.8%; four urgent and three elective). Three patients made a complete recovery, one had permanent expressive dysphasia, and three died. The rate of permanent stroke and death was 2.1%. Endoluminal treatment of thoracic aortic disease is an attractive alternative to open surgery; however, there is still a risk of paraplegia and stroke. Permanent neurological deficits and death occurred in 3.7% of the patients in this series. We conclude that prompt recognition of paraplegia and immediate insertion of a CSF drain can be an effective way of recovering spinal cord function and improving the prognosis

  12. Surgical repair for acute type A aortic dissection in octogenarians.

    Science.gov (United States)

    El-Sayed Ahmad, Ali; Papadopoulos, Nestoras; Detho, Faisal; Srndic, Edin; Risteski, Petar; Moritz, Anton; Zierer, Andreas

    2015-02-01

    Despite limited data, the necessity for immediate surgical intervention in octogenarians with acute type A aortic dissection (AAD) has recently been questioned because the surgical risk may outweigh its potential benefits. At the same time, evolving stent graft technologies are pushing in the market for pathology within the ascending aorta, even for treatment of AAD. Against this background, we analyzed our institutional experience in this patient cohort during the last 8 years. Between October 2005 and October 2013, 39 patients aged older than 80 years (82 ± 2 years) underwent surgical repair for AAD, of which 29 patients (74%) were men. Owing to patient age and comorbidities, we aimed to limit the operation to supracoronary hemiarch replacement whenever possible. Clinical data were prospectively entered into our institutional database. Late follow-up was 3.6 ± 2.8 years and was 100% complete. Hemiarch replacement was performed in 32 patients (82%), and full arch replacement was necessary in the remaining 7. In 31 patients (79%), the aortic root could be glued and reconstructed or remained untouched. The remaining 8 patients (21%) underwent the bio-Bentall procedure. Mean ventilation time was 46 ± 23 hours, and the intensive care unit stay was 5 ± 9 days. We observed new postoperative permanent neurologic deficits in 2 patients (5%) and transient neurologic deficits in 3 (8%). The 30-day mortality was 26% (n = 10). Kaplan-Meier estimates for late survival were 46% ± 16% at 5 years. Given the guidelines regarding the predicted risk of death in patients with untreated AAD, current data suggest a survival benefit with immediate open surgical intervention even in octogenarians. Similarly to the early days of transcatheter-based aortic valve implantation, open surgical reference data are warranted to set the bar for upcoming endovascular treatment of AAD in octogenarians. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights

  13. Blood flow dynamic improvement with aneurysm repair detected by a patient-specific model of multiple aortic aneurysms.

    Science.gov (United States)

    Sughimoto, Koichi; Takahara, Yoshiharu; Mogi, Kenji; Yamazaki, Kenji; Tsubota, Ken'ichi; Liang, Fuyou; Liu, Hao

    2014-05-01

    Aortic aneurysms may cause the turbulence of blood flow and result in the energy loss of the blood flow, while grafting of the dilated aorta may ameliorate these hemodynamic disturbances, contributing to the alleviation of the energy efficiency of blood flow delivery. However, evaluating of the energy efficiency of blood flow in an aortic aneurysm has been technically difficult to estimate and not comprehensively understood yet. We devised a multiscale computational biomechanical model, introducing novel flow indices, to investigate a single male patient with multiple aortic aneurysms. Preoperative levels of wall shear stress and oscillatory shear index (OSI) were elevated but declined after staged grafting procedures: OSI decreased from 0.280 to 0.257 (first operation) and 0.221 (second operation). Graftings may strategically counter the loss of efficient blood delivery to improve hemodynamics of the aorta. The energy efficiency of blood flow also improved postoperatively. Novel indices of pulsatile pressure index (PPI) and pulsatile energy loss index (PELI) were evaluated to characterize and quantify energy loss of pulsatile blood flow. Mean PPI decreased from 0.445 to 0.423 (first operation) and 0.359 (second operation), respectively; while the preoperative PELI of 0.986 dropped to 0.820 and 0.831. Graftings contributed not only to ameliorate wall shear stress or oscillatory shear index but also to improve efficient blood flow. This patient-specific modeling will help in analyzing the mechanism of aortic aneurysm formation and may play an important role in quantifying the energy efficiency or loss in blood delivery.

  14. Mitral valve disease in patients with Marfan syndrome undergoing aortic root replacement.

    Science.gov (United States)

    Kunkala, Meghana R; Schaff, Hartzell V; Li, Zhuo; Volguina, Irina; Dietz, Harry C; LeMaire, Scott A; Coselli, Joseph S; Connolly, Heidi

    2013-09-10

    Cardiac manifestations of Marfan syndrome include aortic root dilation and mitral valve prolapse (MVP). Only scant data exist describing MVP in patients with Marfan syndrome undergoing aortic root replacement. We retrospectively analyzed data from 166 MFS patients with MVP who were enrolled in a prospective multicenter registry of patients who underwent aortic root aneurysm repair. Of these 166 patients, 9% had mitral regurgitation (MR) grade >2, and 10% had MR grade 2. The severity of MVP and MR was evaluated by echocardiography preoperatively and ≤ 3 years postoperatively. Forty-one patients (25%) underwent composite graft aortic valve replacement, and 125 patients (75%) underwent aortic valve-sparing procedures; both groups had similar prevalences of MR grade >2 (P=0.7). Thirty-three patients (20%) underwent concomitant mitral valve (MV) intervention (repair, n=29; replacement, n=4), including all 15 patients with MR grade >2. Only 1 patient required MV reintervention during follow-up (mean clinical follow-up, 31 ± 10 months). Echocardiography performed 21 ± 13 months postoperatively revealed MR >2 in only 3 patients (2%). One early death and 2 late deaths occurred. Although the majority of patients with Marfan syndrome who undergo elective aortic root replacement have MVP, only 20% have concomitant MV procedures. These concomitant procedures do not seem to increase operative risk. In patients with MR grade ≤ 2 who do not undergo a concomitant MV procedure, the short-term incidence of progressive MR is low; however, more follow-up is needed to determine whether patients with MVP and MR grade ≤ 2 would benefit from prophylactic MV intervention.

  15. Aortic intramural hematoma : assessment of clinical and radiological features in comparison to acute aortic dissection

    International Nuclear Information System (INIS)

    Yoon, Kwon Ha; Hwang, Jae Cheol; Lee, Jin Seong; Kang, Duk Hyun; Song, Jae Kwan; Song, Koun Sik; Lim, Tae Hwan

    1996-01-01

    To compare the clinical and radiological features of aortic intramural hematoma(IMH) to those of acute aortic dissection(AD). We analyzed the clinical and radiological features of 12 patients with aortic IMH and 43 patients with acute AD. In aortic IMH, the diagnoses were made by means of both CT and transesophageal echocardiography(TEE) and included two surgically proven cases. In acute AD, the diagnoses were made by means of CT and TEE and included 21 surgically proven cases. We compared patients ages, etiologies, the extent of the disease, the presence or absence of aortic branch involvement, complications, and outcomes. Aortic IMH tended to develop in older patients (67.8±7.9 vs. 50.4±13.4, P .05). In aortic IMH, there was no involvement of aortic branches, whereas in acute AD, 14(33%) patients showed involvement of one or more aortic branches. Complications of aortic IMH included pericardial effusion (n=2) and pleural effusion (n=4);in acute AD, pericardial effusion (n=7), pleural effusion (n=4), aortic insufficiency (n=8), cerebral infarction (n=3), renal infarction (n=4) and spinal infarction (n=1) were seen. There was one (8%) death due to aortic IMH and ten (23%) deaths due to acute AD (p<.01). Aortic IMH is characterized by its occurrence in older patients with hypertension, a less frequent incidence of complications, and a more favorable outcome than acute AD

  16. Decreased expression of fibulin-4 in aortic wall of aortic dissection.

    Science.gov (United States)

    Huawei, P; Qian, C; Chuan, T; Lei, L; Laing, W; Wenlong, X; Wenzhi, L

    2014-02-01

    In this research, we will examine the expression of Fibulin-4 in aortic wall to find out its role in aortic dissection development. The samples of aortic wall were obtained from 10 patients operated for acute ascending aortic dissection and five patients for chronic ascending aortic dissection. Another 15 pieces of samples from patients who had coronary artery bypass were as controls. The aortic samples were stained with aldehyde magenta dyeing to evaluate the arrangement of elastic fibers. The Fibulin-4 protein and mRNA expression were both determined by Western blot and realtime quantitative polymerase chain reaction. Compared with the control group, both in acute and chronic ascending aortic dissection, elastic fiber fragments increased and the expression of fibulin-4 protein significantly decreased (P= 0.045 < 0.05). The level of fibulin-4 mRNA decreased in acute ascending aortic dissection (P= 0.034 < 0.05), while it increased in chronic ascending aortic dissection (P=0.004 < 0.05). The increased amounts of elastic fiber fragments were negatively correlated with the expression of fibulin-4 mRNA in acute ascending aortic dissection. In conclusion, in aortic wall of ascending aortic dissection, the expression of fibulin-4 protein decreased and the expression of fibulin-4 mRNA was abnormal. Fibulin-4 may play an important role in the pathogenesis of aortic dissection.

  17. Seventeen Years’ Experience of Late Open Surgical Conversion after Failed Endovascular Abdominal Aortic Aneurysm Repair with 13 Variant Devices

    International Nuclear Information System (INIS)

    Wu, Ziheng; Xu, Liang; Qu, Lefeng; Raithel, Dieter

    2015-01-01

    PurposeTo investigate the causes and results of late open surgical conversion (LOSC) after failed abdominal aortic aneurysm repair (EVAR) and to summarize our 17 years’ experience with 13 various endografts.MethodsRetrospective data from August 1994 to January 2011 were analyzed at our center. The various devices’ implant time, the types of devices, the rates and causes of LOSC, and the procedures and results of LOSC were analyzed and evaluated.ResultsA total of 1729 endovascular aneurysm repairs were performed in our single center (Nuremberg South Hospital) with 13 various devices within 17 years. The median follow-up period was 51 months (range 9–119 months). Among them, 77 patients with infrarenal abdominal aortic aneurysms received LOSC. The LOSC rate was 4.5 % (77 of 1729). The LOSC rates were significantly different before and after January 2002 (p < 0.001). The reasons of LOSC were mainly large type I endoleaks (n = 51) that were hard to repair by endovascular techniques. For the LOSC procedure, 71 cases were elective and 6 were emergent. The perioperative mortality was 5.2 % (4 of 77): 1 was elective (due to septic shock) and 3 were urgent (due to hemorrhagic shock).ConclusionLarge type I endoleaks were the main reasons for LOSC. The improvement of devices and operators’ experience may decrease the LOSC rate. Urgent LOSC resulted in a high mortality rate, while selective LOSC was relatively safe with significantly lower mortality rate. Early intervention, full preparation, and timely LOSC are important for patients who require LOSC

  18. Survival following ruptured abdominal aortic aneurysm before and during the IMPROVE Trial: a single-centre series.

    Science.gov (United States)

    Ambler, G K; Twine, C P; Shak, J; Rollins, K E; Varty, K; Coughlin, P A; Hayes, P D; Boyle, J R

    2014-04-01

    The first large-scale randomised trial (Immediate Management of the Patient with Rupture: Open Versus Endovascular repair [IMPROVE]) for endovascular repair of ruptured abdominal aortic aneurysm (rEVAR) has recently finished recruiting patients. The aim of this study was to examine the impact on survival after rEVAR when the IMPROVE protocol was initiated in a high volume abdominal aortic aneurysm (AAA) centre previously performing rEVAR. One hundred and sixty-nine patients requiring emergency infrarenal AAA repair from January 2006 to April 2013 were included. Eighty-four patients were treated before (38 rEVAR, 46 open) and 85 (31 rEVAR, 54 open) were treated during the trial period. A retrospective analysis was performed. Before the trial, there was a significant survival benefit for rEVAR over open repair (90-day mortality 13% vs. 30%, p = .04, difference remained significant up to 2 years postoperatively). This survival benefit was lost after starting randomisation (90-day mortality 35% vs. 33%, p = .93). There was an increase in overall 30-day mortality from 15% to 31% (p = .02), while there was no change for open repair (p = .438). There was a significant decrease in general anaesthetic use (p = .002) for patients treated during the trial. Randomised patients had shorter hospital and intensive treatment unit stays (p = .006 and p = .03 respectively). The change in survival seen during the IMROVE trial highlights the need for randomised rather than cohort data to eliminate selection bias. These results from a single centre reinforce those recently reported in IMPROVE. Copyright © 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Seventeen Years’ Experience of Late Open Surgical Conversion after Failed Endovascular Abdominal Aortic Aneurysm Repair with 13 Variant Devices

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Ziheng, E-mail: wuziheng303@hotmail.com [Zhejiang University, Department of Vascular Surgery, The First Affiliated Hospital, School of Medicine (China); Xu, Liang, E-mail: maxalive@163.com [Zhejiang University, Department of Neurosurgery, The Second Affiliated Hospital, School of Medicine (China); Qu, Lefeng, E-mail: qulefeng@gmail.com [The Second Military Medical University, Department of Vascular and Endovascular Surgery, Changzheng Hospital (China); Raithel, Dieter, E-mail: dieter.raithel@rzmail.uni-erlangen.de [Nuremberg Southern Hospital, Department of Vascular and Endovascular Surgery (Germany)

    2015-02-15

    PurposeTo investigate the causes and results of late open surgical conversion (LOSC) after failed abdominal aortic aneurysm repair (EVAR) and to summarize our 17 years’ experience with 13 various endografts.MethodsRetrospective data from August 1994 to January 2011 were analyzed at our center. The various devices’ implant time, the types of devices, the rates and causes of LOSC, and the procedures and results of LOSC were analyzed and evaluated.ResultsA total of 1729 endovascular aneurysm repairs were performed in our single center (Nuremberg South Hospital) with 13 various devices within 17 years. The median follow-up period was 51 months (range 9–119 months). Among them, 77 patients with infrarenal abdominal aortic aneurysms received LOSC. The LOSC rate was 4.5 % (77 of 1729). The LOSC rates were significantly different before and after January 2002 (p < 0.001). The reasons of LOSC were mainly large type I endoleaks (n = 51) that were hard to repair by endovascular techniques. For the LOSC procedure, 71 cases were elective and 6 were emergent. The perioperative mortality was 5.2 % (4 of 77): 1 was elective (due to septic shock) and 3 were urgent (due to hemorrhagic shock).ConclusionLarge type I endoleaks were the main reasons for LOSC. The improvement of devices and operators’ experience may decrease the LOSC rate. Urgent LOSC resulted in a high mortality rate, while selective LOSC was relatively safe with significantly lower mortality rate. Early intervention, full preparation, and timely LOSC are important for patients who require LOSC.

  20. Molecular and cellular mechanisms of aortic stenosis.

    Science.gov (United States)

    Yetkin, Ertan; Waltenberger, Johannes

    2009-06-12

    Calcific aortic stenosis is the most common cause of aortic valve replacement in developed countries, and this condition increases in prevalence with advancing age. The fibrotic thickening and calcification are common eventual endpoint in both non-rheumatic calcific and rheumatic aortic stenoses. New observations in human aortic valves support the hypothesis that degenerative valvular aortic stenosis is the result of active bone formation in the aortic valve, which may be mediated through a process of osteoblast-like differentiation in these tissues. Additionally histopathologic evidence suggests that early lesions in aortic valves are not just a disease process secondary to aging, but an active cellular process that follows the classical "response to injury hypothesis" similar to the situation in atherosclerosis. Although there are similarities with the risk factor and as well as with the process of atherogenesis, not all the patients with coronary artery disease or atherosclerosis have calcific aortic stenosis. This review mainly focuses on the potential vascular and molecular mechanisms involved in the pathogenesis of aortic valve stenosis. Namely extracellular matrix remodeling, angiogenesis, inflammation, and eventually osteoblast-like differentiation resulting in bone formation have been shown to play a role in the pathogenesis of calcific aortic stenosis. Several mediators related to underlying mechanisms, including growth factors especially transforming growth factor-beta1 and vascular endothelial growth factors, angiogenesis, cathepsin enzymes, adhesion molecules, bone regulatory proteins and matrix metalloproteinases have been demonstrated, however the target to be attacked is not defined yet.

  1. Compression of the right coronary artery by an aortic pseudoaneurysm after infective endocarditis: an unusual case of myocardial ischemia

    Directory of Open Access Journals (Sweden)

    Lacalzada-Almeida J

    2017-12-01

    Full Text Available Juan Lacalzada-Almeida,1 Alejandro De la Rosa-Hernández,1 María Manuela Izquierdo-Gómez,1 Javier García-Niebla,2 Iván Hernández-Betancor,1 Juan Alfonso Bonilla-Arjona,3 Antonio Barragán-Acea,1 Ignacio Laynez-Cerdeña1 1Cardiology Department, Hospital Universitario de Canarias, Tenerife, 2Health services from the Health Area of El Hierro, V