WorldWideScience

Sample records for infected hip prosthesis

  1. Evaluation of possible hip prosthesis infection with In-111 leukocyte scintigraphy

    International Nuclear Information System (INIS)

    Noto, R.B.; Alavi, A.; Star, A.M.; Cuckler, J.M.; Eisenberg, B.

    1987-01-01

    To evaluate the utility of In-111 leukocyte scintigraphy in patients with possible hip prosthesis infection, the authors retrospectively reviewed 44 such scans without clinical history. The results of In-111 leukocyte scans were compared with intraoperative cultures obtained at the time of prosthesis revision in 34 patients, with hip aspirates and/or clinical follow-up obtained in the remaining ten patients. This comparison yielded a 71% sensitivity, 78% specificity, and 77% overall accuracy. They conclude that In-111 leukocyte scans can be helpful in the evaluation of suspected hip prosthesis infection, but they are not as accurate as has been previously reported elsewhere

  2. Debridement, antibiotics, irrigation, and retention (DAIR) of the prosthesis after hip hemiarthroplasty infections. Does it work?

    Science.gov (United States)

    Kazimoglu, Cemal; Yalcin, Nadir; Onvural, Burak; Akcay, Serkan; Agus, Haluk

    2015-08-01

    Debridement, antibiotic, and implant retention (DAIR) is an attractive treatment modality after hip hemiarthroplasty (HA) infections. Data about the success of the procedure after acute onset infections is lacking. The aim of this study was to analyze the clinical outcome and associated risk factors. A multicenter, retrospective cohort study was designed, including 39 patients with acute onset prosthetic infection who had undergone debridement and irrigation with prosthesis retention. The primary outcome measure was infection eradication without prosthesis removal. We also analyzed how the success rate was influenced by the length of the interval between implantation of the prosthesis and the beginning of the treatment. The overall success rate was 41%. Sedimentation rate over 60 mm/h and the longer duration (2 weeks) after prosthesis implantation were found as factors negatively influencing the success rate. Our results indicated limited success to DAIR- treated patients with infected HA. The high failure rate of DAIR treatment after 2 weeks from the implantation should be taken into consideration.

  3. Life Estimation of Hip Joint Prosthesis

    Science.gov (United States)

    Desai, C.; Hirani, H.; Chawla, A.

    2015-07-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  4. [Tripolar arthroplasty for recurrent total hip prosthesis dislocation].

    Science.gov (United States)

    Beaulé, P-E; Roussignol, X; Schmalzried, T-P; Udomkiat, P; Amstutz, H-C; Dujardin, F-H

    2003-05-01

    The purpose of this study was to assess the results of revision surgery for recurrent total hip prosthesis dislocation using a tripolar prosthesis composed of a conventional stem with a mobile head of an intermediary prosthesis measuring more than 40 mm and a modified cup. This technique was used in two centers in Rouen France and Los Angeles USA. Twenty-one hips in 21 patients were operated on. The mobile heads measured 40 to 47 mm. Mean patient age was 70 years (range 29-92). The indication for the tripolar prosthesis was reserved for extremely unstable hips in patients with major risk factors for recurrent dislocation. These 21 patients had experienced 95 dislocations. The acetabular cup was custom-made for the large-diameter heads. A cemented polyethylene cup was used in 14 cases and a press-fit metal-backed around a polyethylene insert in 7. The polyethylene thickness varied from 6.5 to 16 mm for the cemented cups and 4 to 5 mm for the press-fit cups. Fourteen femoral stems were left in place as were two press-fit cups where only the inserts were changed. Mean follow-up was 5.4 years (range 3-11.8). There has been no recurrent dislocation for 20 hips. One patient experienced a dislocation one week after surgery which required a second revision procedure to reposition the acetabular implant. Final outcome was good at 7.6 years for this hip. One patient who had not had any recurrent dislocation died 4 years after the revision surgery due to a cause unrelated to the prosthesis. Two patients were lost to follow-up at 3.7 and 6 years, both were pain free and had no radiological anomalies. Infection occurred in one patient undergoing chemotherapy for a myeloma; the head and neck had to be resected. For the 20 other patients, functional outcome, assessed with the UCLA score, showed improvement in pain (5.8 preoperatively, 9.2 at last follow-up), walking (4.8 and 8 respectively), function (4 and 6 respectively), and daily activities (3.3 and 5.2 respectively). A

  5. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic cemented or... Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted...

  6. Patients with hip prosthesis: radiotherapy treatment planning considerations

    International Nuclear Information System (INIS)

    Ganesh, K.M.; Supe, Sanjay S.

    2000-01-01

    The number of patients with hip prosthesis undergoing radiotherapy for pelvic cancer worldwide is increasing. This might be of importance depending on the materials in the prosthesis and whether any of the treatment fields are involved in the prosthesis. Radiotherapy planning involving the pelvic region of patients having total hip prosthesis has been found to be difficult due to the effect of the prosthesis on the dose distribution. This review is intended to project dosimetric considerations and possible solutions to this uncommon problem

  7. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metal/polymer... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part...

  8. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) trunnion-bearing... Devices § 888.3380 Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis is a two...

  9. 21 CFR 888.3400 - Hip joint femoral (hemi-hip) metallic resurfacing prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic resurfacing... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3400 Hip joint femoral (hemi-hip) metallic resurfacing prosthesis. (a) Identification. A hip joint femoral (hemi-hip...

  10. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular...

  11. Impact of hip prosthesis on dose distribution of pelvic radiotherapy

    International Nuclear Information System (INIS)

    Ren Jiangping; Zhang Songfang; Zhu Qibao; Guo Jianxin; Zha Yuanzi

    2011-01-01

    Objective: To study the scattering effect of Co-Cr-Mo hip prosthesis which was high Z material for patients undergoing pelvic irradiation. Methods: The hip prosthesis was set in water phantom (30 cm x 30 cm x 30 cm), determining points were chosen on the entrance side of both 6 MV and 10 MV beams at the distance of 0.5 cm, 1.0 cm, 2.0 cm to the hip prosthesis, and also on the exit side of both 6 MV and 10 MV beams at the distance of 3.0 cm, 5.0 cm, 7.0 cm to the hip prostheses. Dose behind the hip prosthesis at depths of 5.0 cm and 10.0 cm for 6 MV and 10 MV beams are also measured. Results: The dose deviation on the beams' entrance side is between 0 to 5.0%, the backscatter effect was more obviously with the higher energy beam. The dose deviation on the beams' exit side was between 21.6%-30.8%. With the same field size and depth, dose deviation becomes smaller when the beam energy was higher; while with the same energy and depth, dose deviation becomes smaller when the field size was bigger. Dose profiles behind the head of the hip prosthesis indicate obvious attenuation of the beam. Conclusions: Beam arrangements that avoid the prosthesis should be considered first or we should at least reduce the weight of the beam that pass through the prosthesis. (authors)

  12. [Mid-term effectiveness of total hip arthroplasty with collum femoris preserving prosthesis].

    Science.gov (United States)

    Li, Mingqing; Hu, Yihe; Li, Kanghua; Liao, Qiande; Wen, Ting; Zhong, Da

    2012-08-01

    To discuss the clinical application of total hip arthroplasty (THA) with collum femoris preserving (CFP) prosthesis and to analyze the mid-term effectiveness. Between January 2004 and February 2007, 45 patients (48 hips) underwent THA with CFP prosthesis. There were 29 males (31 hips) and 16 females (17 hips) with an average age of 48.8 years (range, 38-60 years), including 20 left hips, 22 right hips, and 3 bilateral hips. The causes of hip replacement were osteoarthritis (20 cases), avascular necrosis of femoral head (13 cases), dysplasia (4 cases), rheumatoid arthritis (3 cases), posttraumatic osteoarthritis (2 cases), ankylosing spondylitis (2 cases), and Perths disease (1 case). The average disease duration was 6.1 years (range, 2-13 years). Harris scores, visual analogue scale (VAS) score, and the hip range of motion (ROM) were recorded at pre- and post-operation. The X-ray films were taken at pre- and post-operation to observe the position, loosening of the prosthesis, and ectopic ossification. The gait of patients were also evaluated during follow-up. Short-form 36 health survey scale (SF-36) was used to evaluate the life quality of patients. All 45 patients were followed up 5-8 years with an average of 6.4 years. All the incisions healed by first intention. No infection, hip dislocation, nerve injury, or deep vein thrombosis occurred. Six cleavage fractures (13.3%) of the lateral femoral diaphysis at the distal prosthesis occurred during operation, which healed at 8 months postoperatively without any treatment. Mild ectopic ossification occurred in 4 patients (8.9%) who had no discomfort. Five patients (11.1%) had bone mineral density loss in the region of the proximal femur. The survival rates of the cups and stems were all 100% at last follow-up. The results of Harris score, VAS score, and ROM of the hip joint at 1 year postoperatively and last follow-up were significantly better than preoperative ones (P 0.05) except the Harris score (P fair in 6 hips

  13. Femoral hip prosthesis design for Thais using multi-objective shape optimization

    International Nuclear Information System (INIS)

    Virulsri, Chanyaphan; Tangpornprasert, Pairat; Romtrairat, Parineak

    2015-01-01

    Highlights: • A multi-objective shape optimization was proposed to design hip prosthesis for Thais. • The prosthesis design was optimized in terms of safety of both cement and prosthesis. • The objective functions used the Soderberg fatigue strength formulations. • Safety factors of the cement and prosthesis are 1.200 and 1.109 respectively. • The newly designed prosthesis also fits well with chosen small-sized Thai femurs. - Abstract: The long-term success of Total Hip Arthroplasty (THA) depends largely on how well the prosthetic components fit the bones. The majority of cemented femoral hip prosthesis failures are due to aseptic loosening, which is possibly caused by cracking of the cement mantle. The strength of cement components is a function of cement mantles having adequate thickness. Since the size and shape of cemented femoral hip prostheses used in Thailand are based on designs for a Caucasian population, they do not properly conform to most Thai patients’ physical requirements. For these reasons, prostheses designed specifically for Thai patients must consider the longevity and functionality of both cement and prosthesis. The objective of this study was to discover a new design for femoral hip prostheses which is not only optimal and safe in terms of both cement and prosthesis, but also fits the selected Thai femur. This study used a small-sized Thai femoral model as a reference model for a new design. Biocompatible stainless steel 316L (SS316L) and polymethylmethacrylate (PMMA) were selected as raw materials for the prosthesis and bone cement respectively. A multi-objective shape optimization program, which is an interface between optimization C program named NSGA-II and a finite element program named ANSYS, was used to optimize longevity of femoral hip prostheses by varying shape parameters at assigned cross-sections of the selected geometry. Maximum walking loads of sixty-kilograms were applied to a finite element model for stress and

  14. Hip arthroplasty. Part 1: prosthesis terminology and classification

    International Nuclear Information System (INIS)

    Pluot, E.; Davis, E.T.; Revell, M.; Davies, A.M.; James, S.L.J.

    2009-01-01

    Hip arthroplasty is an extremely common orthopaedic procedure and there is a wide array of implants that are in current use in the UK. The follow-up of patients who have undergone insertion of a hip prosthesis is shifting from a consultant-lead hospital service towards primary care. As this change in patient care continues it becomes increasingly important that an accurate description of the radiographic features is communicated to the primary-care practitioner so appropriate specialist input can be triggered. This review focuses on the terminology and classification of hip prostheses. This acts as a precursor for Part 2 of this series, which describes the normal and abnormal radiographic findings following hip prosthesis insertion.

  15. Do hip prosthesis related infection codes in administrative discharge registers correctly classify periprosthetic hip joint infection?

    DEFF Research Database (Denmark)

    Lange, Jeppe; Pedersen, Alma B; Troelsen, Anders

    2015-01-01

    PURPOSE: Administrative discharge registers could be a valuable and easily accessible single-sources for research data on periprosthetic hip joint infection. The aim of this study was to estimate the positive predictive value of the International Classification of Disease 10th revision (ICD-10...... in future single-source register based studies, but preferably should be used in combination with alternate data sources to ensure higher validity....... decreased to 82% (95% CI: 72-89). CONCLUSIONS: Misclassification must be expected and taken into consideration when using administrative discharge registers for epidemiological research on periprosthetic hip joint infection. We believe that the periprosthetic hip joint infection diagnosis code can be of use...

  16. Good results in postoperative and hematogenous deep infections of 89 stable total hip and knee replacements with retention of prosthesis and local antibiotics.

    Science.gov (United States)

    Geurts, Jan A P; Janssen, Daniël M C; Kessels, Alfons G H; Walenkamp, Geert H I M

    2013-12-01

    Deep postoperative and hematogenous prosthesis infections may be treated with retention of the prosthesis, if the prosthesis is stable. How long the infection may be present to preclude a good result is unclear. We retrospectively studied 89 deep-infected stable prostheses from 69 total hip replacements and 20 total knee replacements. There were 83 early or delayed postoperative infections and 6 hematogenous. In the postoperative infections, treatment had started 12 days to 2 years after implantation. In the hematogenous infections, symptoms had been present for 6 to 9 days. The patients had been treated with debridement, prosthesis retention, systemic antibiotics, and local antibiotics: gentamicin-PMMA beads or gentamicin collagen fleeces. The minimum follow-up time was 1.5 years. We investigated how the result of the treatment had been influenced by the length of the period the infection was present, and by other variables such as host characteristics, infection stage, and type of bacteria. In postoperative infections, the risk of failure increased with a longer postoperative interval: from 0.2 (95% CI: 0.1-0.3) if the treatment had started ≥ 4 weeks postoperatively to 0.5 (CI: 0.2-0.8) if it had started at ≥ 8 weeks. The relative risk for success was 0.6 (CI: 0.3-0.95) if the treatment had started ≥ 8 weeks. In the hematogenous group, 5 of 6 infections had been treated successfully. A longer delay before the start of the treatment caused an increased failure rate, but this must be weighed against the advantage of keeping the prosthesis. We consider a failure rate of < 50% to be acceptable, and we therefore advocate keeping the prosthesis for up to 8 weeks postoperatively, and in hematogenous infections with a short duration of symptoms.

  17. [Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis].

    Science.gov (United States)

    Medenica, Ivica; Luković, Milan; Radoicić, Dragan

    2010-02-01

    The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score--7.1). We performed total rearthroplasty by a custom-made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score--87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specificaly for a patient) and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  18. Total hip arthroplasty using a short-stem prosthesis: restoration of hip anatomy.

    Science.gov (United States)

    Amenabar, Tomas; Marimuthu, Kanniraj; Hawdon, Gabrielle; Gildone, Alessandro; McMahon, Stephen

    2015-04-01

    To evaluate hip parameters such as vertical centre of rotation (VCR), horizontal centre of rotation (HCR), femoral offset, and leg length after total hip arthroplasty (THA) using the Nanos short-stem prosthesis. Medical records of 73 men and 74 women aged 25 to 92 (mean, 63) years who underwent THA using the Nanos short-stem prosthesis by a single surgeon were reviewed. Prior to the surgery, the optimal cup and stem size, head length, and level of the neck osteotomy were determined using radiographs. Intra-operatively, the leg length and femoral offset were checked, and the level of neck resection and head length were adjusted. VCR, HCR, femoral offset, and leg length of the operated and contralateral sides were compared. Functional outcomes were assessed using the Harris Hip Score (HHS). Compared with the normal contralateral hips, the operated hips had a mean increase of 0.4 mm in VCR (p=0.032), a mean decrease of 1.4 mm in HCR (p=0.027), a mean increase of 0.6 mm in femoral offset (p=0.043), and a mean increase of 0.36 mm in leg length (p=0.035). For these respective parameters, the difference between the normal contralateral side and the operated side was within 5 mm in 89%, 80%, 71%, and 96% of patients. The HHS improved from a mean of 53 to 91 at one year (pNanos short-stem prosthesis enabled restoration of hip anatomy (VCR, HCR, femoral offset, and leg length).

  19. Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis

    Directory of Open Access Journals (Sweden)

    Medenica Ivica

    2010-01-01

    Full Text Available Background. The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. Case report. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score - 7.1. We performed total rearthroplasty by a custom- made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score - 87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Conclusion. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specifically for a patient and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  20. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    International Nuclear Information System (INIS)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul

    1987-01-01

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component

  1. Metabolic Pattern of Asymptomatic Hip-Prosthesis by 18F-FDG-Positron-Emission-Tomography

    International Nuclear Information System (INIS)

    Beslic, Nermina; Heber, Daniel; Walter Lipp, Rainer; Sonneck-Koenne, Charlotte; Knoll, Peter; Mirzaei, Siroos

    2015-01-01

    Joint replacement is a procedure with a major impact on the quality of life of patients with joint degenerative disease or traumatic injuries. However, some patients develop symptoms after the intervention caused by mechanical loosening or infection. Metabolic imaging by 18F-FDG-PET investigated in these patients isoften hampered by low specificity for diagnosis of possible septic vs. mechanical loosening. The reason for this shortcoming is to our opinion the unawareness of physiological remodeling processes that could be seen in asymptomatic patients. In order to overcome this drawback, we aimed to find out the physiological metabolic functional pattern in asymptomatic patients with implanted hip prosthesis Twelve patients (6 males, 6 females); mean age 73 ± 7 (range 58 - 91) years were prospectively enrolled in the study. The patients were admitted to our department for oncological referral with implanted hip prostheses. All patients explained no symptoms with regard to their implanted prosthesis. The attenuation corrected images were used for analysis. Fourteen hip prostheses in 12 patients were visually analyzed. Seven out of 14 prostheses among 12 patients showed focal periprosthetic enhanced metabolism, two of which showed two sites of enhanced uptake; whereas, the remaining five prostheses showed singular hypermetabolic areas within the periprosthetic site. The remaining seven prostheses in the other five patients showed no periprosthetic-enhanced uptake. Of the asymptomatic patients investigated, 58% showed focal enhanced periprosthetic glucose metabolism. This finding should be taken into consideration as a more probable unspecific metabolic pattern for correct interpretation of 18F-FDG-PET studies in patients with suspected septic loosening of the hip prosthesis

  2. Bicentric bipolar hip prosthesis: A radiological study of movement at the interprosthetic joint

    Directory of Open Access Journals (Sweden)

    Anil Kumar Rai

    2011-01-01

    Full Text Available Background: The bipolar hip prostheses after some time functions as a unipolar device. There is a need to change the design of bipolar hip prostheses to make it function as a bipolar device over a prolonged period of time. A bicentric bipolar hip prosthesis was used as an implant for various conditions of the hip. We evaluated the movement of this newly developed prosthesis at the interprosthetic joint radiologically at periodic intervals. Materials and Methods: Fifty two cases were operarted with the Bicentric bipolar prosthesis for indications like fracture neck of femur and various other diseases of the hip and were followed up with serial radiographs at periodic intervals to evaluate, what fraction of the total abduction at the hip was occurring at the interprosthetic joint. Results: In cases of intracapsular fracture neck of femur, the percentage of total abduction occurring at the interprosthetic joint at 3 months follow-up was 33.74% (mean value of all the patients, which fell to 25.66% at 1.5 years. In indications for bipolar hemireplacement other than fracture neck of femur, the percentage of total abduction occurring at the interprosthetic joint at 3 months follow-up was 71.71% (mean value and at 1.5 years it was 67.52%. Conclusion: This study shows the relative preservation of inner bearing movement in the bipolar hip prosthesis with time probably due its refined design. Further refinements are needed to make the prosthesis work better in patients of intracapsular fracture neck femur.

  3. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul [College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    1987-10-15

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component.

  4. 21 CFR 888.3358 - Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer/metal semi-constrained... Devices § 888.3358 Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis. (a) Identification. A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device...

  5. Combined bone scintigraphy with 99mTc-MDP and 99mTc-ciprofloxacin in differentiation of hip and knee prosthesis aseptic loosening and infection: A preliminary study

    Directory of Open Access Journals (Sweden)

    Pucar Dragan

    2017-01-01

    Full Text Available Background/Aim. Although the number of new primary implantation of hip and knee prostheses every year increases, the rate of failed arthroplasty is nearly the same. The main question is whether it is an aseptic instability or instability caused by infection. The aim of this preliminary study was an attempt with combined 99mTc-ciprofloxacin and 99mTc-methylene diphosphonate (MDP bone scintigraphy to improve diagnostic accuracy in the differentiation of hip and knee prosthesis aseptic loosening and periprosthetic joint infection. Methods. Inclusion criteria of patients for this study were based on suspected periprosthetic joint infection: painful prosthetic joint, restricted joint movements and increased value of erythrocyte sedimentation rate or levels of C-reactive protein. We examined 20 patients with implanted 14 hip and 6 knee prosthesis. All patients also underwent plain radiography of suspected joint. In all patients, three-phase 99mTc-MDP bone scintigraphy was performed. Three to five days after the bone scan, we performed scintigraphy using 99mTc-ciprofloxacin with the calculation of accumulation index. Periprosthetic joint infection was confirmed on the basis of microbiological findings. Results. Periprosthetic joint infection was confirmed in fourteen of twenty observed joints, in five of them the aseptic loosening was present and in one patient’s symptoms were not related to the prosthesis (poor biomechanics of prosthetic joints caused by weaknesses of muscle. Estimated sensitivity/specificity for 99mTc-MDP bone scintigraphy alone were 100/17%; for 99mTc-ciprofloxacin scintigraphy were 85,7/100%. Sensitivity and specificity were 92,3% and 83,3%, respectively for results obtained with combined assessment by both methods. Our study confirmed the high negative predictive value of 99mTc-MDP bone scan. The negative result of bone scan virtually excludes the possibility of periprosthetic infection. On the other hand, positive findings of

  6. Accuracy of CT-guided joint aspiration in patients with suspected infection status post-total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Tomas, Xavier; Garcia-Diez, Ana Isabel; Pomes, Jaime [Universidad de Barcelona, Department of Radiology, Hospital Clinic, Barcelona (Spain); Bori, Guillem; Garcia, Sebastian; Gallart, Xavier; Martinez, Juan Carlos; Riba, Josep [Universidad de Barcelona, Department of Orthopaedics, Hospital Clinic, Barcelona (Spain); Soriano, Alex; Mensa, Josep [Universidad de Barcelona, Department of Infectious Diseases, Hospital Clinic, Barcelona (Spain); Rios, Jose [Statistical Unit de Suport a la Estadistica I Metodologia IDIBAPS, Barcelona (Spain); Almela, Manel [Universidad de Barcelona, Department of Microbiology, Hospital Clinic, Barcelona (Spain)

    2011-01-15

    To determine the accuracy of guided computed tomography aspiration in the detection of septic hip prosthesis before surgery. Sixty-three patients (35 women and 28 men; age range, 29-86 years; mean age, 71 years) with clinically suspected septic hip prosthesis were prospectively studied with independent review board (IRB) approval. Volume and microbiological cultures of aspirated fluid and several computed tomography imaging findings such as periprosthetic fluid collections, prosthetic acetabular malposition, and heterotopic ossification were analyzed. All patients underwent revision surgery and infection was finally diagnosed in 33 patients. Statistical comparative analysis was performed comparing computed tomography aspiration and surgical findings (95% CI; level of significance at P = 0.05 two-sided) with 70% sensitivity, 100% specificity, 84% accuracy, 100% positive predictive value, and 75% negative predictive value. Using Fisher's exact test, the presence of periprosthetic fluid collections (P = 0.001), prosthetic acetabular malposition (P = 0.025) and aspirated fluid volume (P = 0.009) were significantly higher in infected than in non-infected prostheses, whereas heterotopic ossification was not (P = 0.429). Computed tomography aspiration is accurate to preoperatively diagnose septic hip prosthesis on the basis of volume and bacterial cultures of aspirated joint fluid. Furthermore, imaging findings such as periprosthetic fluid collections and prosthetic acetabular malposition strongly suggest infected prosthesis. (orig.)

  7. Accuracy of CT-guided joint aspiration in patients with suspected infection status post-total hip arthroplasty

    International Nuclear Information System (INIS)

    Tomas, Xavier; Garcia-Diez, Ana Isabel; Pomes, Jaime; Bori, Guillem; Garcia, Sebastian; Gallart, Xavier; Martinez, Juan Carlos; Riba, Josep; Soriano, Alex; Mensa, Josep; Rios, Jose; Almela, Manel

    2011-01-01

    To determine the accuracy of guided computed tomography aspiration in the detection of septic hip prosthesis before surgery. Sixty-three patients (35 women and 28 men; age range, 29-86 years; mean age, 71 years) with clinically suspected septic hip prosthesis were prospectively studied with independent review board (IRB) approval. Volume and microbiological cultures of aspirated fluid and several computed tomography imaging findings such as periprosthetic fluid collections, prosthetic acetabular malposition, and heterotopic ossification were analyzed. All patients underwent revision surgery and infection was finally diagnosed in 33 patients. Statistical comparative analysis was performed comparing computed tomography aspiration and surgical findings (95% CI; level of significance at P = 0.05 two-sided) with 70% sensitivity, 100% specificity, 84% accuracy, 100% positive predictive value, and 75% negative predictive value. Using Fisher's exact test, the presence of periprosthetic fluid collections (P = 0.001), prosthetic acetabular malposition (P = 0.025) and aspirated fluid volume (P = 0.009) were significantly higher in infected than in non-infected prostheses, whereas heterotopic ossification was not (P = 0.429). Computed tomography aspiration is accurate to preoperatively diagnose septic hip prosthesis on the basis of volume and bacterial cultures of aspirated joint fluid. Furthermore, imaging findings such as periprosthetic fluid collections and prosthetic acetabular malposition strongly suggest infected prosthesis. (orig.)

  8. Dosimetric influence of hip prosthesis during radiotherapeutic treatment

    International Nuclear Information System (INIS)

    Gschwind, R.; Buffard, E.; Masset, H.; Makovicka, L.; David, C.; David, C.; Buffard, E.

    2008-01-01

    As the population become aged, many patients with hip prosthesis are treated for a pelvic cancer. The recommended ballistic must avoid to pass in the prosthesis, but sometimes it is inevitable. So it is essential to quantify with accuracy the dose modifications linked to the presence of metallic implant. The aim of this study is to analyze by Monte Carlo method these modifications in simple and complex models (anthropomorphic phantom) which take into account the geometry and the composition of the prosthesis and its coatings. Then, this methodology was used to study the behaviour of a treatment planning system in theses extreme conditions. (authors)

  9. 21 CFR 888.3340 - Hip joint metal/composite semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/composite semi-constrained... Hip joint metal/composite semi-constrained cemented prosthesis. (a) Identification. A hip joint metal... hip joint. The device limits translation and rotation in one or more planes via the geometry of its...

  10. 21 CFR 888.3350 - Hip joint metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer semi-constrained cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3350 Hip joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. A hip joint metal/polymer semi...

  11. 21 CFR 888.3300 - Hip joint metal constrained cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal constrained cemented or uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3300 Hip joint metal constrained cemented or uncemented prosthesis. (a) Identification. A hip joint metal constrained...

  12. Supracondylar correction osteotomy to prevent repetitive posterior dislocation of a hip prosthesis

    NARCIS (Netherlands)

    Haverkamp, D.; Marti, R. K.

    2008-01-01

    Recurrent dislocation of a total hip prosthesis can be a challenging and often disappointing problem. This case report describes a 78-year-old woman who had recurrent posterior dislocations of a revision total hip replacement (THR) that occurred on flexion and internal rotation of the hip. The

  13. SU-E-J-230: Effect of Metal Hip Prosthesis On the Accuracy of Electromagnetic Localization and Tracking

    International Nuclear Information System (INIS)

    Butler, W; Merrick, G; Kurko, B; Bittner, N

    2014-01-01

    Purpose: To quantify the effect of metal hip prosthesis on the ability to track and localize electromagnetic transponders. Methods: Three Calypso transponders were implanted into two prostate phantoms. The geometric center of the transponders were identified on computed tomography and set as the isocenter. With the phantom stationary on the treatment table and the tracking array 14-cm above the isocenter, data was acquired by the Calypso system at 10 Hz to establish the uncertainty in measurements. Transponder positional data was acquired with unilateral hip prostheses of different metallic compositions and then with bilateral hips placed at variable separation from the phantom. Results: Regardless of hip prosthesis composition, the average vector displacement in the presence of a unilateral prosthesis was < 0.5 mm. The greatest contribution to overall vector displacement occurred in the lateral dimension. With bilateral hip prosthesis, the average vector displacement was 0.3 mm. The displacement in the lateral dimension was markedly reduced compared with a unilateral hip, suggesting that there was a countervailing effect with bilateral hip prosthesis. The greatest average vector displacement was 0.6 mm and occurred when bilateral hip prostheses were placed within 4 cm of the detector array. Conclusion: Unilateral and bilateral hip prostheses did not have any meaningful effect on the ability to accurately track electromagnetic transponders implanted in a prostate phantom. At clinically realistic distances between the hip and detection array, the average tracking error is negligible

  14. 99m technetium-MDP bone scintigraphy in evaluation of painful joint prosthesis

    International Nuclear Information System (INIS)

    Milosevic, D.; Jaukovic, M.; Jaukovic, Lj.; Ajdinovic, B.

    2004-01-01

    In addition of clinical evaluation and x-ray radiography, the diagnosis of a loose joint prosthesis is often made by nuclear medicine imaging techniques. Differentiation between loosening and infected prosthesis is important for better treatment of those patients. Aim: The aim of this study was to reevaluate the scintigraphic patterns in patients with painful hip of knee arthroplasty. Material and Method: From 1996. to 2003. forty patients aged 49-78 years were referred for evaluation of possible loosening/infection joint prosthesis: 36 pts with 39 total/ partial hip prosthesis, 1 pt with knee prosthesis and 3 pts with history of previously extracted hip prosthesis due to infection. Whole body acquisition had been performed with a single head gamma camera three hours after the injection of 740 MBq 99m Tc-MDP. Scans were classified as: positive for loosening if abnormal uptake was shown at the tip of the prosthesis; positive for infection if diffuse abnormal uptake was shown around the implant; negative and indeterminate scans. Scintigraphic findings were compared to clinical follow up, histology or cultures. Results: Positive findings were found in 17 bone scans strongly suggesting loosening in 10 cases, infection of prosthesis in 4 cases and both loosening/infection in 3 cases. Bone scintigraphy was normal in 11pts. Scans of three pts with previously extracted hip prosthesis and scheduled for reimplatation, showed inhomogeneously and mildly increased uptake in femur. Most of scans classified as indeterminate (n=12) showed slightly increased tracer uptake in region of acetabular roof, greater or lesser tho chanter, suggesting bone remodeling due to the presence of implant, rather than loosening. Conclusion: 99m Tc-MDP bone scintigraphy had a significant role in assessing the painful joint prosthesis. Complementary diagnostic procedures should be considered in indeterminate scintiscans. (authors)

  15. 21 CFR 888.3310 - Hip joint metal/polymer constrained cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer constrained cemented or... Hip joint metal/polymer constrained cemented or uncemented prosthesis. (a) Identification. A hip joint... replace a hip joint. The device prevents dislocation in more than one anatomic plane and has components...

  16. False-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis

    International Nuclear Information System (INIS)

    Feldman, N.; Makler, P.T. Jr.; Alavi, A.

    1986-01-01

    A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process

  17. Phantom studies of triple photon absorptiometry and bone mineral measurement at a hip prosthesis

    International Nuclear Information System (INIS)

    Farrell, T.J.; Webber, C.E.

    1992-01-01

    The feasibility of using triple photon absorptiometry (TPA) for the measurement of bone mineral mass about a hip prosthesis was examined. A theoretical expression describing the variance of TPA measurements was verified using a triple photon source and phantom materials which simulate the soft tissue-bone mineral-metal prosthesis system. The expression for the variance was used to determine an optimized set of photon energies. It was shown that a precision of 3% could be obtained for reasonable measurement times using this optimized set of energies and that TPA should be a feasible approach for measurement of bone mineral about a hip prosthesis. (orig.)

  18. Prosthesis infections after orthopedic joint replacement

    DEFF Research Database (Denmark)

    Song, Zhijun; Borgwardt, Lotte; Høiby, Niels

    2013-01-01

    Prosthesis-related infection is a serious complication for patients after orthopedic joint replacement, which is currently difficult to treat with antibiotic therapy. Consequently, in most cases, removal of the infected prosthesis is the only solution to cure the infection. It is, therefore...

  19. 21 CFR 888.3410 - Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer or ceramic/polymer... Devices § 888.3410 Hip joint metal/polymer or ceramic/polymer semiconstrained resurfacing cemented prosthesis. (a) Identification. A hip joint metal/polymer or ceramic/polymer semi-constrained resurfacing...

  20. Strain-stress analysis of surface prosthesis of hip joint

    Czech Academy of Sciences Publication Activity Database

    Návrat, Tomáš; Fuis, Vladimír; Florian, Z.; Hlavoň, Pavel

    2007-01-01

    Roč. 40, č. 2 (2007), S559-S559 ISSN 0021-9290. [ISB 2007. Taipei, 01.07.2007-05.07.2007] R&D Projects: GA ČR GA101/05/0136 Institutional research plan: CEZ:AV0Z20760514 Keywords : surface prosthesis * hip joint * FEM Subject RIV: BO - Biophysics Impact factor: 2.897, year: 2007

  1. EVALUATION AND RANKING OF ARTIFICIAL HIP PROSTHESIS SUPPLIERS BY USING A FUZZY TOPSIS METHODOLOGY

    Directory of Open Access Journals (Sweden)

    Marija Zahar Djordjevic

    2014-06-01

    Full Text Available The aim of this study is to propose a fuzzy multi-criteria decision-making approach (MCDM to evaluate the artificial hip prosthesis suppliers with respect to numerous criteria, simultaneously, taking into account the type of each criteria and its relative importance. The fuzzy of the Technique for Order Preference by Similarity to Ideal Solution (FTOSISis applied in order to rank the artificial hip prosthesis suppliers. The rank is obtained using the process of fuzzy number comparison. Software solution based on suggested method is also presented. A real-life example with real data is presented to clarify the proposed method.

  2. Shielding of the Hip Prosthesis During Radiation Therapy for Heterotopic Ossification is Associated with Increased Failure of Prophylaxis

    International Nuclear Information System (INIS)

    Balboni, Tracy A.; Gaccione, Peter; Gobezie, Reuben; Mamon, Harvey J.

    2007-01-01

    Purpose: Radiation therapy (RT) is frequently administered to prevent heterotopic ossification (HO) after total hip arthroplasty (THA). The purpose of this study was to determine if there is an increased risk of HO after RT prophylaxis with shielding of the THA components. Methods and Materials: This is a retrospective analysis of THA patients undergoing RT prophylaxis of HO at Brigham and Women's Hospital between June 1994 and February 2004. Univariate and multivariate logistic regressions were used to assess the relationships of all variables to failure of RT prophylaxis. Results: A total of 137 patients were identified and 84 were eligible for analysis (61%). The median RT dose was 750 cGy in one fraction, and the median follow-up was 24 months. Eight of 40 unshielded patients (20%) developed any progression of HO compared with 21 of 44 shielded patients (48%) (p = 0.009). Brooker Grade III-IV HO developed in 5% of unshielded and 18% of shielded patients (p 0.08). Multivariate analysis revealed shielding (p = 0.02) and THA for prosthesis infection (p = 0.03) to be significant predictors of RT failure, with a trend toward an increasing risk of HO progression with age (p = 0.07). There was no significant difference in the prosthesis failure rates between shielded and unshielded patients. Conclusions: A significantly increased risk of failure of RT prophylaxis for HO was noted in those receiving shielding of the hip prosthesis. Shielding did not appear to reduce the risk of prosthesis failure

  3. Femoral Prosthesis Infection by Rhodotorula mucilaginosa▿

    Science.gov (United States)

    Savini, Vincenzo; Sozio, Federica; Catavitello, Chiara; Talia, Marzia; Manna, Assunta; Febbo, Fabio; Balbinot, Andrea; Di Bonaventura, Giovanni; Piccolomini, Raffaele; Parruti, Giustino; D'Antonio, Domenico

    2008-01-01

    This case report is a case history of a femoral prosthesis infection caused by Rhodotorula mucilaginosa in a human immunodeficiency virus patient. Though the pathogenicity of this organism for bone tissue has been previously reported, this is the first reported case of an orthopedic prosthesis infection by this species of the genus Rhodotorula. PMID:18753353

  4. Gene therapy and cement injection for the treatment of hip prosthesis loosening in elderly patients

    NARCIS (Netherlands)

    Poorter, Jolanda de

    2010-01-01

    Approximately one million total hip replacement operations are performed worldwide annually, mostly for osteoarthritis and rheumatoid arthritis. A major complication in total hip arthroplasties is loosening of the prosthesis leading to pain and walking difficulties and a higher risk for dislocations

  5. Automated estimation of hip prosthesis migration: a feasibility study

    Science.gov (United States)

    Vandemeulebroucke, Jef; Deklerck, Rudi; Temmermans, Frederik; Van Gompel, Gert; Buls, Nico; Scheerlinck, Thierry; de Mey, Johan

    2013-09-01

    A common complication associated with hip arthoplasty is prosthesis migration, and for most cemented components a migration greater than 0.85 mm within the first six months after surgery, are an indicator for prosthesis failure. Currently, prosthesis migration is evaluated using X-ray images, which can only reliably estimate migrations larger than 5 mm. We propose an automated method for estimating prosthesis migration more accurately, using CT images and image registration techniques. We report on the results obtained using an experimental set-up, in which a metal prosthesis can be translated and rotated with respect to a cadaver femur, over distances and angles applied using a combination of positioning stages. Images are first preprocessed to reduce artefacts. Bone and prosthesis are extracted using consecutive thresholding and morphological operations. Two registrations are performed, one aligning the bones and the other aligning the prostheses. The migration is estimated as the difference between the found transformations. We use a robust, multi-resolution, stochastic optimization approach, and compare the mean squared intensity differences (MS) to mutual information (MI). 30 high-resolution helical CT scans were acquired for prosthesis translations ranging from 0.05 mm to 4 mm, and rotations ranging from 0.3° to 3° . For the translations, the mean 3D registration error was found to be 0.22 mm for MS, and 0.15 mm for MI. For the rotations, the standard deviation of the estimation error was 0.18° for MS, and 0.08° for MI. The results show that the proposed approach is feasible and that clinically acceptable accuracies can be obtained. Clinical validation studies on patient images will now be undertaken.

  6. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented acetabular...

  7. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented acetabular...

  8. Breast milk metal ion levels in a young and active patient with a metal-on-metal hip prosthesis.

    Science.gov (United States)

    Nelis, Raymond; de Waal Malefijt, Jan; Gosens, Taco

    2013-01-01

    Metal-on-metal resurfacing arthroplasty of the hip has been used increasingly over the last 10 years in younger active patients. The dissolution of the metal wear particles results in measurable increases in cobalt and chromium ions in the serum and urine of patients with a metal-on-metal bearing. We measured the cobalt, chromium, and molybdenum ion levels in urine; serum; and breast milk in a young and active patient with a metal-on-metal hip prosthesis after a pathologic fracture of the femoral neck. Metal-on-metal hip prosthesis leads to increasing levels of molybdenum in breast milk in the short-term follow-up. There are no increasing levels of chromium and cobalt ions in breast milk. Besides the already known elevated concentrations in serum of chromium and cobalt after implantation of a metal-on-metal hip prosthesis, we found no increasing levels of chromium and cobalt in urine. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. EFFECTS OF DEXAMETHASONE AND PHENIRAMINE MALEATE ON HEMODYNAMIC AND RESPIRATORY PARAMETERS AFTER CEMENTATION IN CEMENTED PARTIAL HIP PROSTHESIS.

    Science.gov (United States)

    Yektaş, Abdulkadir; Gümüş, Funda; Totoz, Tolga; Gül, Nurten; Erkalp, Kerem; Alagöl, Ayşin

    2015-02-01

    To prevent hemodynamic and respiratory changes that are likely to occur during cementation in partial hip prosthesis by prophylactic use of pheniramine maleate and dexamethasone. The study included 40 patients aged between 60 and 85 years with an American Society ofAnesthesiologists (ASA) grade of II-III who underwent partial hip prosthesis. Just after spinal anesthesia, 4 mL normal saline was pushed in patients in Group S, whereas 45.5 mg pheniramine maleate and 8 mg dexamethasone mixture was pushed intravenously in a total volume of 4 mL in patients in Group PD. Amounts of atropine and adrenaline administered after cementation were significantly higher in Group S than in Group PD (P pheniramine maleate and dexamethasone in partial hip prosthesis led to an increase in SpO2 value and a decrease in the utilization of adrenaline and atropine after cementation.

  10. Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

    International Nuclear Information System (INIS)

    Abdullah, Abdul Halim; Nor, Mohd Asri Mohd; Saman, Alias Mohd; Tamin, Mohd Nasir; Kadir, Mohammed Rafiq Abdul

    2010-01-01

    Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3 deg. at anterior/posterior, 3 deg. at medial/lateral and 10 deg. from wide lateral to narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.

  11. Usefulness of positron emission tomography (TEP) in the assessment of osteo-articular prosthesis

    International Nuclear Information System (INIS)

    Maldonado, A.; Suarez, J.P.; Dominguez, M.L.

    2004-01-01

    Joint arthroplasty is performed with increasing frequency as the population ages. Loosening or infection of the prosthesis is a relatively common event that can limit the lifetime of a prosthesis. Accuracy differentiation between aseptic and septic loosening of the prosthesis remains a challenge because of the consequences for patient management. Moreover, an early diagnosis of infected hip prosthesis is very important for optimal and cost-effective management. Various approaches have developed to visualize infection and inflammation by nuclear medicine techniques. Recently positron emission tomography (PET) with fluorine-l8 labelled 2 fluoro-2-deoxyglucose ( 18 F-FDG) has been shown to delineate infectious and inflammatory foci with high sensitivity owing to the increased glucose metabolism in inflammatory cells. In this paper we review the role of FDG-PET in this common differential diagnosis in patients with total knee and hip prostheses. Different patterns of FDG-PET interpretation have been described as wed as methodological aspects. (author)

  12. Prosthetic Hip Loosening Due to Brucellar Infection: Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Anis Tebourbi

    2016-12-01

    Full Text Available Context: Brucellosis is actually considered to be the commonest zoonotic infection worldwide; conversely prosthetic infection due to brucella is extremely rare. Although diagnostic is easily achieved, management of such situations is extremely challenging. Aims: To report the case of prosthetic hip loosening due to brucellar infection, discuss management manners and to summarize data about 19 cases reported in the literature. Methods: We report the case of a 73-year-old woman with brucellar prosthetic hip loosening treated with 2-stage exchange of the prosthesis and prolonged double antibiotherapy Results: At two years follow up the patient is pain free with total functional recovery and no clinical and radiographic signs of prosthetic loosening Conclusions: Brucella should be evocated as a cause of total joint arthroplasty infection especially in patients from endemic regions and with occupational exposure. Antibiotic treatment alone can be followed if there are no signs of implant loosening. Tow stage revision should be considered in other cases.

  13. Imaging of hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T., E-mail: millertt@hss.edu [Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021 (United States)

    2012-12-15

    The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.

  14. Carbon/PEEK composite materials as an alternative for stainless steel/titanium hip prosthesis: a finite element study.

    Science.gov (United States)

    Rezaei, Farshid; Hassani, Kamran; Solhjoei, Nosratollah; Karimi, Alireza

    2015-12-01

    Total hip replacement (THR) has been ranked within the most typical surgical processes in the world. The durability of the prosthesis and loosening of prosthesis are the main concerns that mostly reported after THR surgeries. In THR, the femoral prosthesis can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone has a key asset in its long-term durability and performance. This study aimed to execute a comparative finite element simulation to assess the load transfer between the prosthesis, which is made of carbon/PEEK composite and stainless steel/titanium, and the femur bone. The mechanical behavior of the cortical bone was assumed as a linear transverse isotropic while the spongy bone was modeled like a linear isotropic material. The implants were made of stainless steel (316L) and titanium alloy as they are common materials for implants. The results showed that the carbon/PEEK composites provide a flatter load transfer from the upper body to the leg compared to the stainless steel/titanium prosthesis. Furthermore, the results showed that the von Mises stress, principal stress, and the strain in the carbon/PEEK composites prosthesis were significantly lower than that made of the stainless steel/titanium. The results also imply that the carbon/PEEK composites can be applied to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease the stress shielding and interface stress. These findings will help clinicians and biomedical experts to increase their knowledge about the hip replacement.

  15. Fabrication and characterization of DLC coated microdimples on hip prosthesis heads.

    Science.gov (United States)

    Choudhury, Dipankar; Ay Ching, Hee; Mamat, Azuddin Bin; Cizek, Jan; Abu Osman, Noor Azuan; Vrbka, Martin; Hartl, Martin; Krupka, Ivan

    2015-07-01

    Diamond like carbon (DLC) is applied as a thin film onto substrates to obtain desired surface properties such as increased hardness and corrosion resistance, and decreased friction and wear rate. Microdimple is an advanced surface modification technique enhancing the tribological performance. In this study, DLC coated microdimples were fabricated on hip prosthesis heads and their mechanical, material and surface properties were characterized. An Electro discharge machining (EDM) oriented microdrilling was utilized to fabricate a defined microdimple array (diameter of 300 µm, depth of 70 µm, and pitch of 900 µm) on stainless steel (SS) hip prosthesis heads. The dimpled surfaces were then coated by hydrogenated amorphous carbon (a-C:H) and tetrahedral amorphous carbon (Ta-C) layers by using a magnetron sputtering technology. A preliminary tribology test was conducted on these fabricated surfaces against a ceramic ball in simulated hip joint conditions. It was found that the fabricated dimples were perpendicular to the spherical surfaces and no cutting-tools wear debris was detected inside the individual dimples. The a-C:H and Ta-C coatings increased the hardness at both the dimple edges and the nondimpled region. The tribology test showed a significant reduction in friction coefficient for coated surfaces regardless of microdimple arrays: the lowest friction coefficient was found for the a-C:H samples (µ = 0.084), followed by Ta-C (µ = 0.119), as compared to the SS surface (µ = 0.248). © 2014 Wiley Periodicals, Inc.

  16. Prosthesis infections after orthopedic joint replacement: the possible role of bacterial biofilms

    Directory of Open Access Journals (Sweden)

    Zhijun Song

    2013-06-01

    Full Text Available Prosthesis-related infection is a serious complication for patients after orthopedic joint replacement, which is currently difficult to treat with antibiotic therapy. Consequently, in most cases, removal of the infected prosthesis is the only solution to cure the infection. It is, therefore, important to understand the comprehensive interaction between the microbiological situation and the host immune responses that lead to prosthesis infections. Evidence indicates that prosthesis infections are actually biofilm-correlated infections that are highly resistant to antibiotic treatment and the host immune responses. The authors reviewed the related literature in the context of their clinical experience, and discussed the possible etiology and mechanism leading to the infections, especially problems related to bacterial biofilm, and prophylaxis and treatment of infection, including both microbiological and surgical measures. Recent progress in research into bacterial biofilm and possible future treatment options of prosthesis-related infections are discussed.

  17. Selection of contact bearing couple materials for hip prosthesis using finite element analysis under static conditions

    Science.gov (United States)

    Arirajan, K. A.; Chockalingam, K.; Vignesh, C.

    2018-04-01

    Implants are the artificial parts to replace the missing bones or joints in human anatomy to give mechanical support. Hip joint replacement is an important issue in orthopaedic surgery. The main concern limiting the long-run success of the total hip replacement is the limited service life. Hip replacement technique is widely used in replacing the femur head and acetabular cup by materials that are highly biocompatible. The success of the artificial hip replacement depends upon proper material selection, structure, and shape of the hip prosthesis. Many orthopaedic analyses have been tried with different materials, but ended with partial success on the application side. It is a critical task for selecting the best material pair in the hip prosthesis design. This work develops the finite element analysis of an artificial hip implant to study highest von Mises stress, contact pressure and elastic strain occurs for the dissimilar material combination. The different bearing couple considered for the analysis are Metal on Metal, Metal on Plastic, Metal on Ceramic, Ceramic on Plastic, Ceramic on Ceramic combinations. The analysis is carried out at different static positions of a human (i.e) standing, sitting. The results reveals that the combination with metal in contact with plastic (i.e) Titanium femoral head paired with Ultra High Molecular Weight Poly Ethylene acetabular cup reduces maximum von Mises stress and also it gives lowest contact pressure than other combination of bearing couples.

  18. Assessment of suspected infection of hip or knee endoprosthesis by nuclear medicine techniques

    International Nuclear Information System (INIS)

    Schmidt, M.; Dietlein, M.; Schicha, H.; Delank, K.S.

    2007-01-01

    Complications after hip endoprosthesis operation occur with a frequency of 1-2 % after primary operation and with 3-5 % after revision arthroplasty and are even more frequent after knee arthroplasty. The differentiation between aseptic loosening and bacterial infection is very important. In aseptic loosening a one-step revision is usually possible. In case of bacterial infection, all foreign material has to be removed first to allow cure from the infection. After healing and absence of bacteria a follow-up operation is possible with insertion of a new prosthesis. Diagnosis and therapy of a painful hip or knee endoprosthesis are difficult, because patient history, clinical examination, laboratory results including microbiological investigation of puncture material and results of radiological examinations may all be inconclusive. Quite a number of nuclear medicine procedures have been published in the past to help in the differentiation between aseptic loosening and bacterial infection of a painful hip or knee endoprosthesis. No single method can be regarded as excellent and without disadvantages. In the international literature the combined leucocyte-marrow imaging has been propageted as superior technique. In Germany, combined leucocyte-marrow imaging is not available in the published form. Moreover, this technique is time consuming, cost intensive and requires direct work with blood. Therefore, infection imaging with labelled antibodies or labelled fragments of antibodies may be regarded as the method of choice for most nuclear medicine physicians. With semiquantitative evaluation a comparative diagnostic accuracy may be achieved. 18 F-FDG-PET is not able to differentiate reliably between abacterial polyethylene abrasion and septic inflammation. However, with pattern recognition of the distribution of 18 F-FDG around a hip prosthesis an approach with clinically acceptable results has been published. A normal 18 F-FDG-PET can reliably exclude an infection

  19. [Total hip endoprosthesis following resection arthroplasty].

    Science.gov (United States)

    Engelbrecht, E; Siegel, A; Kappus, M

    1995-08-01

    From 1976 to December 1994, a total of 347 patients underwent implantation of a hip prosthesis at the ENDO-Klinik for treatment of an unsatisfactory condition following resection arthroplasty. From 1976 to 1987, 143 patients were treated and in 1989 the results obtained in these patients were analysed: 99 of them were available for a follow-up examination in 1989, and 64 for a further examination in 1995. In 130 cases infection had been the reason for joint resection. At the time of the prosthesis operation (1-20 years later) intraoperative biopsy revealed that infection was still present in 41 cases (31.5%). Only 15 of these infections had been detected preoperatively by joint aspiration. This shows that the value of resection arthroplasty as a method of treating periprosthetic infection is limited and lends support to the one-stage exchange operation, which is the method we prefer in cases of infected hip prostheses. The operative technique and preparation for implantation of the prosthesis are described, as are septic and aseptic complications and the measures that can be taken to treat them. In spite of the patients' generally poor initial condition and with due consideration for the further revision operations, the medium-term results finally obtained are poor in only 9%.

  20. A Medical Wireless Measurement System for Hip Prosthesis Loosening Detection Based on Vibration Analysis

    Directory of Open Access Journals (Sweden)

    Sebastian Sauer

    2013-01-01

    Full Text Available Vibration analysis is a promising approach in order to detect early hip prosthesis loosening, with the potential to extend the range of diagnostic tools currently available in clinical routine. Ongoing research efforts and developments in the area of multi-functional implants, which integrate sensors, wireless power supply, communication and signal processing, provide means to obtain valuable in vivo information otherwise not available. In the current work a medical wireless measurement system is presented, which is integrated in the femoral head of a hip prosthesis. The passive miniaturized system includes a 3-axis acceleration sensor and signal pre-processing based on a lock-in amplifier circuit. Bidirectional data communication and power supply is reached through inductive coupling with an operating frequency of 125 kHz in accordance with the ISO 18000-2 protocol standard. The system allows the acquisition of the acceleration frequency response of the femur-prosthesis system between 500 to 2500 Hz. Applied laboratory measurements with system prototypes on artificial bones and integrated prostheses demonstrate the feasibility of the measurement system approach, clearly showing differences in the vibration behavior due to an implant loosening. In addition a possibility to evaluate the non-linear mechanic system behavior is presented.

  1. Treatment Challenges of Prosthetic Hip Infection with Associated Iliacus Muscle Abscess: Report of 5 Cases and Literature Review.

    Science.gov (United States)

    Lawrenz, Joshua M; Mesko, Nathan W; Higuera, Carlos A; Molloy, Robert M; Simpfendorfer, Claus; Babic, Maja

    2017-01-01

    Prosthetic joint infection is an unfortunate though well-recognized complication of total joint arthroplasty. An iliacus and/or iliopsoas muscle abscess is a rarely documented presentation of hip prosthetic joint infection. It is thought an unrecognized retroperitoneal nidus of infection can be a source of continual seeding of the prosthetic hip joint, prolonging attempts to eradicate infection despite aggressive debridement and explant attempts. The current study presents five cases demonstrating this clinical scenario, and discusses various treatment challenges. In each case we report the patient's clinical history, pertinent imaging, management and outcome. Diagnosis of the iliacus muscle abscess was made using computed tomography imaging. In brief, the mean number of total drainage procedures (open and percutaneous) per patient was 4.2, and outcomes consisted of one patient with a hip girdlestone, two patients with delayed revisions, and two patients with retained prosthesis. All patients ended with functional pain and on oral antibiotic suppression with an average follow up of 18 months. This article highlights an iliacus muscle abscess as an unrecognized source of infection to a prosthetic hip. It demonstrates resilience to standard treatment protocols for prosthetic hip infection, and is associated with poor patient outcomes. Aggressive surgical debridement appears to remain critical to treatment success, and early retroperitoneal debridement of the abscess should be considered.

  2. Quantifying risk of penile prosthesis infection with elevated glycosylated hemoglobin.

    Science.gov (United States)

    Wilson, S K; Carson, C C; Cleves, M A; Delk, J R

    1998-05-01

    Elevation of glycosylated hemoglobin above levels of 11.5 mg.% has been considered a contraindication to penile prosthesis implantation in diabetic patients. We determine the predictive value of glycosylated hemoglobin A1C in penile prosthesis infections in diabetic and nondiabetic patients to confirm or deny this prevalent opinion. We conducted a 2-year prospective study of 389 patients, including 114 diabetics, who underwent 3-piece penile prosthesis implantation. All patients had similar preoperative preparation without regard to diabetic status, control or glycosylated hemoglobin A1C level. Risk of infection was statistically analyzed for diabetics versus nondiabetics, glycosylated hemoglobin A1C values above and below 11.5 mg.%, insulin dependent versus oral medication diabetics, and fasting blood sugars above and below 180 mg.%. Prosthesis infections developed in 10 diabetics (8.7%) and 11 nondiabetics (4.0%). No increased infection rate was observed in diabetics with high fasting sugars or diabetics on insulin. There was no statistically significant increased infection risk with increased levels of glycosylated hemoglobin A1C among all patients or among only the diabetics. In fact, there was no meaningful difference in the median or mean level of glycosylated hemoglobin A1C in the infected and noninfected patients regardless of diabetes. Use of glycosylated hemoglobin A1C values to identify and exclude surgical candidates with increased risk of infections is not proved by this study. Elevation of fasting sugar or insulin dependence also does not increase risk of infection in diabetics undergoing prosthesis implantation.

  3. Intensity-Modulated Radiation Therapy with Noncoplanar Beams for Treatment of Prostate Cancer in Patients with Bilateral Hip Prosthesis-A Case Study

    International Nuclear Information System (INIS)

    Brooks, Chris; Cheung, Rex Min; Kudchadker, Rajat J.

    2010-01-01

    Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral hip prostheses. The treatment was planned for 75.6 Gy using a 7-field coplanar approach and a noncoplanar arrangement, with all fields avoiding entrance though the prostheses. Our results indicate that, compared with the coplanar plan, the noncoplanar plan delivers the prescribed dose to the target with a slightly better conformality and sparing of rectal tissue versus the coplanar plan.

  4. A phantom study of dose compensation behind hip prosthesis using portal dosimetry and dynamic MLC

    International Nuclear Information System (INIS)

    Nielsen, Martin Skovmos; Carl, Jesper; Nielsen, Jane

    2008-01-01

    Background and purpose: A dose compensation method is presented for patients with hip prosthesis based on Dynamic Multi Leaves Collimator (DMLC) planning. Calculations are done from an exit Portal Dose Image (PDI) from 6 MV Photon beam using an Electronic Portal Imaging Device (EPID) from Varian. Four different hip prostheses are used for this work. Methods: From an exit PDI the fluence needed to yield a uniform dose distribution behind the prosthesis is calculated. To back-project the dose distribution through the phantom, the lateral scatter is removed by deconvolution with a point spread function (PSF) determined for depths from 10 to 40 cm. The dose maximum, D max , is determined from the primary plan which delivers the PDI. A further deconvolution to remove the dose glare effect in the EPID is performed as well. Additionally, this calculated fluence distribution is imported into the Treatment Planning System (TPS) for the final calculation of a DMLC plan. The fluence file contains information such as the relative central axis (CAX) position, grid size and fluence size needed for correct delivery of the DMLC plan. GafChromic EBT films positioned at 10 cm depth are used as verification of uniform dose distributions behind the prostheses. As the prosthesis is positioned at the phantom surface the dose verifications are done 10 cm from the prosthesis. Conclusion: The film measurement with 6 MV photon beam shows uniform doses within 5% for most points, but with hot/cold spots of 10% near the femoral head prostheses

  5. SU-F-T-374: Dosimetric Effects of Irradiation Through a Bilateral Hip Prosthesis in a MRI Linac

    International Nuclear Information System (INIS)

    Wronski, M; Sarfehnia, A; Sahgal, A; Keller, B; Ahmad, S

    2016-01-01

    Purpose: To evaluate the interface effects when irradiating through a hip prosthesis in the presence of an orthogonal 1.5 T magnetic field using Monte Carlo simulations. Methods: A 20×20×38 cm virtual phantom with two 5×5×5 cm sections of bilateral titanium hip prosthesis was created in GPU-based Monte Carlo (MC) algorithm (GPUMCD, Elekta AB, Stockholm Sweden). The lateral prosthesis spacing was based on a representative patient CT scan. A treatment SAD of 143.5 cm was chosen, corresponding to the Elekta AB MRI Linac and the beam energy distribution was sampled from a histogram representing the true MRI Linac spectrum. A magnetic field of 1.5 T was applied perpendicular to the plane of irradiation. Dose was calculated, in voxels of side 1 mm, for 2×2, 5×5, and 10×10 cm treatment field sizes with normal beam incidence (gantry at 90° or 270°) and at 5° and 10° from normal, representing the range of incidence through the bilateral prosthesis. Results: With magnetic field ON (B-On) and normal beam incidence the backscatter dose at the interfaces of proximal and distal implants is reduced for all the field sizes compared to the magnetic field OFF (B-Off) case. The absolute reduction in doses at the interface was in the range of 12.93% to 13.16% for the proximal implant and 13.57% to 16.12% for the distal implant. Similarly for the oblique incidences of 5o and 10o the dose in the plane adjacent to the prosthetic implants is lower when the magnetic field is ON. Conclusion: The dosimetric effects of irradiating through a hip prosthesis in the presence of a transverse magnetic field have been determined using MC simulation. The backscatter dose reduction translates into significantly lower hot spots at the prosthetic interfaces, which are otherwise substantially high in the absence of the magnetic field. This project was supported through funding provided by ElektaTM.

  6. SU-F-T-374: Dosimetric Effects of Irradiation Through a Bilateral Hip Prosthesis in a MRI Linac

    Energy Technology Data Exchange (ETDEWEB)

    Wronski, M; Sarfehnia, A; Sahgal, A; Keller, B [Sunnybrook Odette Cancer Center, Toronto (Canada); University of Toronto, Department of Radiation Oncology, Toronto (Canada); Ahmad, S [Sunnybrook Odette Cancer Center, Toronto (Canada)

    2016-06-15

    Purpose: To evaluate the interface effects when irradiating through a hip prosthesis in the presence of an orthogonal 1.5 T magnetic field using Monte Carlo simulations. Methods: A 20×20×38 cm virtual phantom with two 5×5×5 cm sections of bilateral titanium hip prosthesis was created in GPU-based Monte Carlo (MC) algorithm (GPUMCD, Elekta AB, Stockholm Sweden). The lateral prosthesis spacing was based on a representative patient CT scan. A treatment SAD of 143.5 cm was chosen, corresponding to the Elekta AB MRI Linac and the beam energy distribution was sampled from a histogram representing the true MRI Linac spectrum. A magnetic field of 1.5 T was applied perpendicular to the plane of irradiation. Dose was calculated, in voxels of side 1 mm, for 2×2, 5×5, and 10×10 cm treatment field sizes with normal beam incidence (gantry at 90° or 270°) and at 5° and 10° from normal, representing the range of incidence through the bilateral prosthesis. Results: With magnetic field ON (B-On) and normal beam incidence the backscatter dose at the interfaces of proximal and distal implants is reduced for all the field sizes compared to the magnetic field OFF (B-Off) case. The absolute reduction in doses at the interface was in the range of 12.93% to 13.16% for the proximal implant and 13.57% to 16.12% for the distal implant. Similarly for the oblique incidences of 5o and 10o the dose in the plane adjacent to the prosthetic implants is lower when the magnetic field is ON. Conclusion: The dosimetric effects of irradiating through a hip prosthesis in the presence of a transverse magnetic field have been determined using MC simulation. The backscatter dose reduction translates into significantly lower hot spots at the prosthetic interfaces, which are otherwise substantially high in the absence of the magnetic field. This project was supported through funding provided by ElektaTM.

  7. Ultrasound-Guided Femoral Nerve Block to Facilitate the Closed Reduction of a Dislocated Hip Prosthesis

    Directory of Open Access Journals (Sweden)

    Edward Carlin

    2017-10-01

    Full Text Available Prosthetic hip dislocation is a common but unfortunate complication in patients who have undergone total hip arthroplasty. Successful closed reduction in the emergency department leads to a reduced length of stay and rate of hospitalization. 1, 2 The use of regional anesthesia by femoral nerve block represents a novel approach for controlling pain in patients with hip pathologies. 3 Ultrasound-guided approaches have been used with great success for controlling pain in patients with hip fractures. 4, 5 Here we report the case of a 90-year-old male who presented with a dislocated hip prosthesis, which was subsequently corrected with closed reduction following delivery of regional anesthesia to the femoral nerve under ultrasound guidance. To our knowledge, this represents the first reported use of an ultrasound-guided femoral nerve block to facilitate closed reduction of a dislocated prosthetic hip, and highlights a novel approach that avoids the use of procedural sedation in an elderly patient.

  8. Adventure sports and sexual freedom hip replacement: the tripolar hip.

    Science.gov (United States)

    Pritchett, James W

    2018-01-01

    Certain athletic activities and lifestyles require a completely stable and very mobile hip. Total hip replacement with a natural femoral head size and two mobile-bearing surfaces (i.e., a "tripolar" prosthesis) is the most stable prosthesis. Elegant design and wear-resistant bearing surfaces are the keys to long-term implant survivorship. The hypothesis is that a ceramic-coated tripolar prosthesis using highly cross-linked polyethylene can provide full function and complete stability with low wear. This study sought to determine: (1) patient-reported outcomes, (2) functional outcomes, (3) implant survivorship and complications, and (4) postoperative sexual limitations. Between 1998 and 2011, the author performed 160 primary total hip replacements using tripolar prostheses in patients participating in adventure sports and other physically demanding activities. The institutional review board approved this study. The inclusion criteria were patients who needed unrestricted activity and who were not candidates for or did not choose hip resurfacing. Patients were followed every second year and assessed with radiographs, Harris Hip Score, WOMAC, SF-12, and UCLA functional outcome scores. Patients were asked about symptoms of instability and satisfaction with their hip replacement. Patients were asked both preoperatively and 2 years postoperatively four questions about their sexual activity. Mean follow-up was 11 years. At 2 years' postoperatively, 98% of patients reported their satisfaction as excellent or good and 99% were not limited for sexual activity following surgery. Seventy-four percent of patients reported they were recovered within 6 weeks of surgery. There were no dislocations. There were three revision procedures for implant loosening, infection, and periprosthetic fracture, but there were no failures of the tripolar articulation. The mean postoperative UCLA score was the highly athletic score of 8. There were no signs of osteolysis, wear, or metal

  9. Calculation of wear (f.i. wear modulus) in the plastic cup of a hip joint prosthesis

    NARCIS (Netherlands)

    Ligterink, D.J.

    1975-01-01

    The wear equation is applied to the wear process in a hip joint prosthesis and a wear modulus is defined. The sliding distance, wear modulus, wear volume, wear area, contact angle and the maximum normal stress were calculated and the theoretical calculations applied to test results. During the wear

  10. Persistent non-specific FDG uptake on PET imaging following hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, Hongming; Chacko, Thomas K.; Hickeson, Marc; Stevenson, Karen; Feng, Qi; Ponzo, Fabio; Alavi, Abass [Division of Nuclear Medicine, Department of Radiology, The Hospital of University of Pennsylvania, 110 Donner Building, 3400 Spruce Street, Philadelphia, PA 19104 (United States); Garino, Jonathan P. [Department of Orthopedic Surgery, The Hospital of University of Pennsylvania, Philadelphia, PA 19802 (United States)

    2002-10-01

    Hip arthroplasty is a common surgical procedure, but the diagnosis of infection associated with hip arthroplasty remains challenging. Fluorine-18 fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) has been shown to be a promising imaging modality in settings where infection is suspected. However, inflammatory reaction to surgery can result in increased FDG uptake at various anatomic locations, which may erroneously be interpreted as sites of infection. The purpose of this study was to assess the patterns and time course of FDG accumulation following total hip replacement over an extended period of time. Firstly, in a prospective study nine patients with total hip replacement were investigated to determine the patterns of FDG uptake over time. Three FDG-PET scans were performed in each patient at about 3, 6 and 12 months post arthroplasty. Secondly, in a retrospective analysis, the medical and surgical history and FDG-PET imaging results of 710 patients who had undergone whole-body scans for the evaluation of possible malignant disorders were reviewed. The history of arthroplasty and FDG-PET findings in the hip region were reviewed for this study. Patients with symptomatic arthroplasties or related complaints during FDG-PET scanning were excluded from the analysis. During the entire study period, all nine patients enrolled in the prospective study were demonstrated to have increased FDG uptake around the femoral head or neck portion of the prosthesis that extended to the soft tissues surrounding the femur. Among the patients reviewed in the retrospective study, 18 patients with a history of 21 hip arthroplasties who were asymptomatic at the time of FDG-PET scan met the criteria for inclusion. The time interval between the hip arthroplasty and the FDG-PET study ranged from 3 months to 288 months (mean{+-}SD: 80.4{+-}86.2 months). In 81% (17 of 21) of these prostheses, increased FDG uptake could be noted around the femoral head or neck portion of the

  11. Application of individually performed acrylic cement spacers containing 5% of antibiotic in two-stage revision of hip and knee prosthesis due to infection.

    Science.gov (United States)

    Babiak, Ireneusz

    2012-07-03

    Deep infection of a joint endoprosthesis constitutes a threat to the stability of the implant and joint function. It requires a comprehensive and interdisciplinary approach, involving the joint revision and removal of the bacterial biofilm from all tissues, the endoprosthesis must be often removed and bone stock infection treated. The paper presents the author's experience with the use of acrylic cement spacers, custom-made during the surgery and containing low dose of an antibiotic supplemented with 5% of a selected, targeted antibiotic for the infection of hip and knee endoprostheses. 33 two-stage revisions of knee and hip joints with the use of a spacer were performed. They involved 24 knee joints and 9 hip joints. The infections were mostly caused by staphylococci MRSA (18) and MSSA (8), and in some cases Enterococci (4), Salmonella (1), Pseudomonas (1) and Acinetobacter (1). The infection was successfully treated in 31 out of 33 cases (93.93%), including 8 patients with the hip infection and 23 patients with the knee infection. The endoprosthesis was reimplanted in 30 cases: for 7 hips and 23 knees, in 3 remaining cases the endoprosthesis was not reimplanted. Mechanical complications due to the spacer occurred in 4 cases: 3 dislocations and 1 fracture (hip spacer). The patients with hip spacers were ambulatory with a partial weight bearing of the operated extremity and those with knee spacers were also ambulatory with a partial weight bearing, but the extremity was initially protected by an orthosis. The spacer enables to maintain a limb function, and making it by hand allows the addition of the specific bacteria targeted antibiotic thus increasing the likelihood of the effective antibacterial treatment.

  12. Numerical evaluation of bone remodelling and adaptation considering different hip prosthesis designs.

    Science.gov (United States)

    Levadnyi, Ievgen; Awrejcewicz, Jan; Gubaua, José Eduardo; Pereira, Jucélio Tomás

    2017-12-01

    The change in mechanical properties of femoral cortical bone tissue surrounding the stem of the hip endoprosthesis is one of the causes of implant instability. We present an analysis used to determine the best conditions for long-term functioning of the bone-implant system, which will lead to improvement of treatment results. In the present paper, a finite element method coupled with a bone remodelling model is used to evaluate how different three-dimensional prosthesis models influence distribution of the density of bone tissue. The remodelling process begins after the density field is obtained from a computed tomography scan. Then, an isotropic Stanford model is employed to solve the bone remodelling process and verify bone tissue adaptation in relation to different prosthesis models. The study results show that the long-stem models tend not to transmit loads to proximal regions of bone, which causes the stress-shielding effect. Short stems or application in the calcar region provide a favourable environment for transfer of loads to the proximal region, which allows for maintenance of bone density and, in some cases, for a positive variation, which causes absence of the aseptic loosening of an implant. In the case of hip resurfacing, bone mineral density changes slightly and is closest to an intact femur. Installation of an implant modifies density distribution and stress field in the bone. Thus, bone tissue is stimulated in a different way than before total hip replacement, which evidences Wolff's law, according to which bone tissue adapts itself to the loads imposed on it. The results suggest that potential stress shielding in the proximal femur and cortical hypertrophy in the distal femur may, in part, be reduced through the use of shorter stems, instead of long ones, provided stem fixation is adequate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Diagnostic value of bone scintigraphy with sup(99m)Tc-pyrophosphate for evaluation of complications after hip joint replacement

    International Nuclear Information System (INIS)

    Baumer, J.F.

    1979-01-01

    For 102 patients with complaints after total hip replacement, bone scintigraphies with sup(99m)Tc have been made in addition to the usual examinations. 95 of these patients had to be operated once more, whereas the infected endoprosteses detected in the remaining 7 patients have been treated for the time being by non-surgical measures. In 68 patients, the examination revealed an aseptic loosening of the total endoprosthesis, including fracture of the diaphysis in 19 cases. In one case, a replacement of the prosthesis had been necessary in spite of the alloarthroplasty being firmly fixed in the right place. The bacterioscopic and bacteriologic investigations clearly revealed an infection of the environment of the prosthesis, in 27 patients, whereas the findings obtained on 6 other patients have not been as unambiguons. 85% of the patients with septic complications showed an increased E.S.R., however only 26% of the patients with aseptic complications. In only 47% of the patients with infection of the hip joint, bacteria have been found in the hip joint puncture fluid, whereas the bacteriological examination of tissue taken from the environment of the artificial hip joint during the operation revealed no increase in bacteria in only one case (5%). In 4 patients (20%), the bacterioscopic findings showed no signs of an acute infection, although saprophytic germs had been isolated from the environment of the prosthesis. 78% of the cases with loosening of the prosthesis and 11% of the infections have been detected by X-ray examination. The nuclear medical examination showed normal radionuclide accumulation in 30% of the cases with loosened prosthesis and in 4% of the infections, for 6% each of the two complications the scintigrams yielded no unambiguous results. In 4 patients (40%) with total hip joint replacement on both sides, enhanced radionuclide accumulation has been abserved even on the symptom-free side. (orig./AJ) [de

  14. Current and future biocompatibility aspects of biomaterials for hip prosthesis

    Directory of Open Access Journals (Sweden)

    Amit Aherwar

    2015-12-01

    Full Text Available The field of biomaterials has turn into an electrifying area because these materials improve the quality and longevity of human life. The first and foremost necessity for the selection of the biomaterial is the acceptability by human body. However, the materials used in hip implants are designed to sustain the load bearing function of human bones for the start of the patient’s life. The most common classes of biomaterials used are metals, polymers, ceramics, composites and apatite. These five classes are used individually or in combination with other materials to form most of the implantation devices in recent years. Numerous current and promising new biomaterials i.e. metallic, ceramic, polymeric and composite are discussed to highlight their merits and their frailties in terms of mechanical and metallurgical properties in this review. It is concluded that current materials have their confines and there is a need for more refined multi-functional materials to be developed in order to match the biocompatibility, metallurgical and mechanical complexity of the hip prosthesis.

  15. Indications of 99mTc-MDP scintigraphy bone scan in the evaluation of painful hip arthroplasties

    International Nuclear Information System (INIS)

    Eder, V.; Baulieu, F.; Secchi, V.; Gautier, B.; Pottier, J.M.; Rosset, P.

    2000-01-01

    The purpose of this study was to determine the indication of bone scintigraphy in hip prosthesis complications. Thirty-six patients and 38 hip prosthesis have had a 99 Tc-MDP scintigraphy in our laboratory between 1995 and 1997. It concerns 32 cemented total prosthesis, 3 intermediate prosthesis and 3 non-cemented total prosthesis. For 14 prosthesis, complication (loosening or infection) was confirmed by surgical operation in 12 cases (4 isolated acetabular complications, 2 isolated femoral loosening, 3 global loosening and 3 infections) or by concordant data from different examinations in 2 cases (global loosening) where intervention was unrealizable. About other patients, absence of complication was confirmed by a favourable evolution lasting at least 12 months. A cetabular and femoral complications were detected by scintigraphy respectively with a sensitivity of 100 % and 90 %, a specificity of 85 % and 78 %, a PPV of 75 % and 60 % and NPV of 100 % and 96 %. High negative predictive value allows to eliminate a prosthesis complication in the case of a normal scintigraphy and to override decision when the clinic and the radiography are doubtful. Scintigraphy may recognize other bone fixation abnormalities which may be responsible of clinical symptomatology. (authors)

  16. An evaluation of the role of nuclear medicine imaging in the diagnosis of periprosthetic infections of the hip

    International Nuclear Information System (INIS)

    Trevail, C.; Ravindranath-Reddy, P.; Sulkin, T.; Bartlett, G.

    2016-01-01

    Aim: To validate the role of nuclear medicine (NM) imaging in hip periprosthetic joint infection (PJI) of hip arthroplasties. Materials and methods: This was a retrospective study of 235 consecutive patients referred to NM for investigation of a symptomatic hip prosthesis. Imaging comprised Tc-99m bone scintigraphy, In-111 white cell scintigraphy, and bone marrow scintigraphy if required. Imaging findings were compared with intraoperative microbiology and histology, clinical findings and follow up for ≥24 months. Results: There were 14 exclusions. Of the 221 remaining patients, there were 16 true positives, one false positive, 200 true negatives, and four false negatives. The algorithm used at this centre demonstrated an accuracy of 97.7% with high specificity of 99.5% and sensitivity of 80%. Conclusion: When modern NM techniques and accurate reporting criteria are used, scintigraphy is an effective tool for diagnosing PJI of the hip. NM is only given a marginal role in the recent American Association of Orthopedic Surgeons guidelines, and the orthopaedic community should reconsider their evaluation of this technique. - Highlights: • Nuclear Medicine can accurately diagnose periprosthetic infection. • NM has an integral role in the rational management of periprosthetic infection. • SPECT CT has a potential role in improving accuracy.

  17. Chronic infections in hip arthroplasties

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Thomsen, Reimar W

    2012-01-01

    Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two-stage revisi......Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two......-stage revisions for chronic infection in hip arthroplasties....

  18. Articulating spacers used in two-stage revision of infected hip and knee prostheses abrade with time.

    Science.gov (United States)

    Fink, Bernd; Rechtenbach, Annett; Büchner, Hubert; Vogt, Sebastian; Hahn, Michael

    2011-04-01

    Articulating spacers used in two-stage revision surgery of infected prostheses have the potential to abrade and subsequently induce third-body wear of the new prosthesis. We asked whether particulate material abraded from spacers could be detected in the synovial membrane 6 weeks after implantation when the spacers were removed for the second stage of the revision. Sixteen hip spacers (cemented prosthesis stem articulating with a cement cup) and four knee spacers (customized mobile cement spacers) were explanted 6 weeks after implantation and the synovial membranes were removed at the same time. The membranes were examined by xray fluorescence spectroscopy, xray diffraction for the presence of abraded particles originating from the spacer material, and analyzed in a semiquantitative manner by inductively coupled plasma mass spectrometry. Histologic analyses also were performed. We found zirconium dioxide in substantial amounts in all samples, and in the specimens of the hip synovial lining, we detected particles that originated from the metal heads of the spacers. Histologically, zirconium oxide particles were seen in the synovial membrane of every spacer and bone cement particles in one knee and two hip spacers. The observations suggest cement spacers do abrade within 6 weeks. Given the presence of abrasion debris, we recommend total synovectomy and extensive lavage during the second-stage reimplantation surgery to minimize the number of abraded particles and any retained bacteria.

  19. Comportamiento a fatiga del vástago de una prótesis para cadera al caminar//Fatigue behavior stem hip prosthesis for walking

    Directory of Open Access Journals (Sweden)

    Ángel Martínez-Delfín

    2014-01-01

    Full Text Available La prótesis de cadera consiste en sustituir la parte superior fracturada del fémur por una pieza de material biocompatible. Debido a las cargas aleatorias que sobre esta prótesis actúan al caminar la persona injertada, surge la fatiga sobre la prótesis. En este trabajo se realiza el cálculo a fatiga del vástago de una prótesis de caderas fabricada con acero inoxidable austenítico AISI 316L GrQ y de uso actual. Para ellose emplea el método de los elementos finitos, considerando la compleja geometría del vástago, el material y las cargas variables resultantes del caminar de la persona con la prótesis artificial colocada. Se calcula el daño a fatiga que estas cargas provocan en la misma así como el número de pasos que pueden darse, garantizándose una larga vida útil de la prótesis por este concepto de resistencia.Palabras claves: fatiga, prótesis de cadera, ciclo, daño, elementos finitos.______________________________________________________________________________AbstractThe hip prosthesis consists in substituting the fractured femur part by a piece of biocompatible material. Because the random character of loads acting over this prosthesis while person walk, crop up the fatigue on the prosthesis. The fatigue behavior of austenitic stainless steel hips prosthesis is studied in this article. The method of finite elements is used, considering the complex geometry of the part, the material and the variable acting loads, as results of steps of walking person. The fatigue damages are calculated as well as the number of steps that can be given, guarantying a long life of the prosthesis for fatigue resistance concept.Key words: fatigue, hip prosthesis, cycle, damage, finite elements.

  20. Infection imaging with 99mTc-biotin in patients with prosthetic hip replacement

    International Nuclear Information System (INIS)

    Villa, G.; Mariani, G.; Augeri, C.; Pipino, F.; Paganelli, G.; Chinol, M.

    2002-01-01

    Full text: Although the incidence of infection in prosthetic hip joint replacements has decreased from about 10-15 % to about 0.5-2 % over the last 20 years, the total number of infections has actually increased because of the large number of patients undergoing the procedure. The most frequent clinical presentation of this complication is functional impairment and pain, with or without fever and other signs and/or symptoms of infection. The main is differentiating true infection from simple loosening with inflammation of the implanted stem. Scintigraphy with radiolabeled autologous leukocytes (WBC) represents the 'gold standard' nuclear medicine procedure for imaging infection. However, this procedure is time-consuming, expensive, and involves some biological hazard. Preliminary data, obtained during validation of the avidin/111In-biotin approach, have suggested some potential of 111ln-biotin per se to accumulate at sites of infection. In this pilot study we explored the potential of 99mTc-biotin as an infection imaging agent in pts with orthopedic infections. N4-lys-biotin was labeled with 1110 MBq. Sixteen pts bearing a total of 20 prosthetic hip replacements were enrolled in the study (9 women and 7 men, mean age 73.2 yrs). Eight pts had previously undergone removal of their hip prosthesis because of infection, while infection was suspected in the remaining 8 pts. Scintigraphy was recorded 20 min, then 1, 4 and 24 hr after the i.v. injection of 99mTc-biotin. Within 48 hrs of the 99mTc-biotin study, all pts also underwent scintigraphy with 99mTc-HMPAO-WBC. Out of the 20 hips evaluated, 15 turned out to be infected while in the remaining 5 cases pain was only caused by bone-prosthetic loosening and/or conditions other than infection. In 12/15 infected sites scintigraphy was concordantly positive with both procedures, 99mTc-biotin yielding higher target-to-nontarget ratios than 99mTc-HMPAO-WBC in 4 cases and similar values in the other cases. Discordant patterns

  1. Bone mineral density after implantation of a femoral neck hip prosthesis--a prospective 5 year follow-up.

    Science.gov (United States)

    Steens, Wolfram; Boettner, Friedrich; Bader, Rainer; Skripitz, Ralf; Schneeberger, Alberto

    2015-08-12

    Bone resorption in the proximal femur due to stress shielding has been observed in a number of conventional cementless implants used in total hip arthroplasty. Short femoral-neck implants are claiming less interference with the biomechanics of the proximal femur. The goal of this study was to prospectively investigate the in vivo changes of bone-mineral density as a parameter of bone remodeling around a short, femoral neck prosthesis over the first 5 years following implantation. The secondary goal was to report on its clinical outcome. We are reporting on the changes of bone mineral density of the proximal femur and the clinical outcome up to five years after implantation of a short femoral neck prosthesis. Bone mineral density was determined using dual energy x-ray absorptiometry, performed 10 days, three, 12 and 60 months after surgery. 20 patients with a mean age of 47 years (range 17 to 65) were clinically assessed using the Harris Hip Score. The WOMAC was used as a patient-relevant outcome-measure. In contrast to conventional implants DEXA-scans overall revealed a slight increase of bone mineral density in the proximal femur in the 12 months following the implantation. The Harris Hip Score improved from an average preoperative score of 46 to a postoperative score at 12 months of 91 points and 95 points at 60 months, the global WOMAC index from 5.3 preoperatively to 0.8 at 12 months and 0.6 at 60 months postoperatively. At 60 months after implantation of a short femoral neck prosthesis, all regions except one (region of interest #5) showed no significant changes in BMD compared to baseline measurements at 10 days which is less to the changes in bone mineral density seen in conventional implants.

  2. The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations

    International Nuclear Information System (INIS)

    Lin, S.-Y.; Chu, T.-C.; Lin, J.-P.; Liu, M.-T.

    2002-01-01

    Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm 2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD Bone , PDD Ti and PDD Co , respectively. The dose re-buildup, which occurs behind the hip region, becomes more and more obvious for denser medium existed in water. Increasing inhomogeneity also enhances the underdosage of ADAC for greater depth (>10 cm), as the figures of nearly 2% in PDD Bone , PDD Ti and 4-5% in PDD Co reveal. Overestimating the attenuated power of high-density non-water material in ADAC TPS causes this underdosage. For dose profiles, no significant differences were found in Profile Bone at any depth. Profile Ti reveals that MC slightly exceeds ADAC at off-axis position 1.0-2.0 cm. Profile Co reveals this more obviously. This finding means that scatter radiation from these denser materials is significant and cannot be predicted precisely in ADAC

  3. Usefulness of positron emission tomography (TEP) in the assessment of osteo-articular prosthesis; Utilite de la tomographie par emission de positons (TEP) dans l'etude des protheses osteo-articulaires

    Energy Technology Data Exchange (ETDEWEB)

    Maldonado, A.; Suarez, J.P.; Dominguez, M.L. [Centro PET Complutense, Madrid (Spain)

    2004-12-15

    Joint arthroplasty is performed with increasing frequency as the population ages. Loosening or infection of the prosthesis is a relatively common event that can limit the lifetime of a prosthesis. Accuracy differentiation between aseptic and septic loosening of the prosthesis remains a challenge because of the consequences for patient management. Moreover, an early diagnosis of infected hip prosthesis is very important for optimal and cost-effective management. Various approaches have developed to visualize infection and inflammation by nuclear medicine techniques. Recently positron emission tomography (PET) with fluorine-l8 labelled 2 fluoro-2-deoxyglucose ({sup 18}F-FDG) has been shown to delineate infectious and inflammatory foci with high sensitivity owing to the increased glucose metabolism in inflammatory cells. In this paper we review the role of FDG-PET in this common differential diagnosis in patients with total knee and hip prostheses. Different patterns of FDG-PET interpretation have been described as wed as methodological aspects. (author)

  4. [Total knee and hip prosthesis: variables associated with costs].

    Science.gov (United States)

    Herrera-Espiñeira, Carmen; Escobar, Antonio; Navarro-Espigares, José Luis; Castillo, Juan de Dios Lunadel; García-Pérez, Lidia; Godoy-Montijano, Amparo

    2013-01-01

    The elevated prevalence of osteoarthritis in Western countries, the high costs of hip and knee arthroplasty, and the wide variations in the clinical practice have generated considerable interest in comparing the associated costs before and after surgery. To determine the influence of a number of variables on the costs of total knee and hip arthroplasty surgery during the hospital stay and during the one-year post-discharge. A prospective multi-center study was performed in 15 hospitals from three Spanish regions. Relationships between the independent variables and the costs of hospital stay and postdischarge follow-up were analyzed by using multilevel models in which the "hospital" variable was used to group cases. Independent variables were: age, sex, body mass index, preoperative quality of life (SF-12, EQ-5 and Womac questionnaires), surgery (hip/knee), Charlson Index, general and local complications, number of beds and economic-institutional dependency of the hospital, the autonomous region to which it belongs, and the presence of a caregiver. The cost of hospital stay, excluding the cost of the prosthesis, was 4,734 Euros, and the post-discharge cost was 554 Euros. With regard to hospital stay costs, the variance among hospitals explained 44-46% of the total variance among the patients. With regard to the post-discharge costs, the variability among hospitals explained 7-9% of the variance among the patients. There is considerable potential for reducing the hospital stay costs of these patients, given that more than 44% of the observed variability was not determined by the clinical conditions of the patients but rather by the behavior of the hospitals.

  5. Insufficient sensitivity of joint aspiration during the two-stage exchange of the hip with spacers.

    Science.gov (United States)

    Boelch, Sebastian Philipp; Weissenberger, Manuel; Spohn, Frederik; Rudert, Maximilian; Luedemann, Martin

    2018-01-10

    Evaluation of infection persistence during the two-stage exchange of the hip is challenging. Joint aspiration before reconstruction is supposed to rule out infection persistence. Sensitivity and specificity of synovial fluid culture and synovial leucocyte count for detecting infection persistence during the two-stage exchange of the hip were evaluated. Ninety-two aspirations before planned joint reconstruction during the two-stage exchange with spacers of the hip were retrospectively analyzed. The sensitivity and specificity of synovial fluid culture was 4.6 and 94.3%. The sensitivity and specificity of synovial leucocyte count at a cut-off value of 2000 cells/μl was 25.0 and 96.9%. C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) values were significantly higher before prosthesis removal and reconstruction or spacer exchange (p = 0.00; p = 0.013 and p = 0.039; p = 0.002) in the infection persistence group. Receiver operating characteristic area under the curve values before prosthesis removal and reconstruction or spacer exchange for ESR were lower (0.516 and 0.635) than for CRP (0.720 and 0.671). Synovial fluid culture and leucocyte count cannot rule out infection persistence during the two-stage exchange of the hip.

  6. Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis.

    Science.gov (United States)

    Chen, Qingshan; Lazennec, Jean Yves; Guyen, Olivier; Kinbrum, Amy; Berry, Daniel J; An, Kai-Nan

    2005-07-01

    Tripolar total hip arthroplasty (THA) prosthesis had been suggested as a method to reduce the occurrence of hip dislocation and microseparation. Precisely measuring the motion of the intermediate component in vitro would provide fundamental knowledge for understanding its mechanism. The present study validates the accuracy and repeatability of a three-dimensional motion analysis system to quantitatively measure the relative motion of the intermediate component of tripolar total hip arthroplasty prostheses. Static and dynamic validations of the system were made by comparing the measurement to that of a potentiometer. Differences between the mean system-calculated angle and the angle measured by the potentiometer were within +/-1 degrees . The mean within-trial variability was less than 1 degrees . The mean slope was 0.9-1.02 for different angular velocities. The dynamic noise was within 1 degrees . The system was then applied to measure the relative motion of an eccentric THA prosthesis. The study shows that this motion analysis system provides an accurate and practical method for measuring the relative motion of the tripolar THA prosthesis in vitro, a necessary first step towards the understanding of its in vivo kinematics.

  7. Complications in total and partial hip and knee replacement in the San Jose Universitary Hospital Popayan

    Directory of Open Access Journals (Sweden)

    Alejandro Sandoval-Daza

    2010-03-01

    Full Text Available Introduction: Total hip and knee replacements are surgical procedures commonly used in cases of degenerative articular problems, intrarticular fractures and less common in tumor conditions. Despite its great success complications can arise. Objective: Describe complications in total knee and hip replacements. Methods: A descriptive study, cases serie was done in Hospital Universitario San José in Popayán Colombia, analyzing the period between January 2004 and January 2009, Seventy six patients were included: 53 total hips replacements, 12 cases of partial hip replacements and 11 total knee replacements. Patient's age was in the range between 27 and 97. Results: The main complications founded were: respiratory insufficiency, inability to place the prosthesis, prosthesis dislocation, anemic syndrome, acetabular protrusion, infection, iatrogenic Gushing's syndrome, discrepancy of length limb, residual pain, inability to walk, nosocomial pneumonia, renal failure and periprosthetic fracture. An average of 4, 6% mortality index, 10, 8% hip prosthesis dislocation, 9, 2% infections, all these indices over the different literature reports.

  8. Sequential use of technetium 99m MDP and gallium 67 citrate imaging in the evaluation of painful total hip replacement

    International Nuclear Information System (INIS)

    Horoszowski, H.; Ganel, A.; Kamhin, M.; Zaltman, S.; Farine, I.

    1980-01-01

    Fourteen patients with 20 total hip joint replacements were studied for 14 painful prosthetic hips. Clinical examination, plain film radiographs and 99 Tcsup(m)-methylene diphosphonate bone scans failed to differentiate between infection and mechanical loosening of a prosthesis. Sequential use of 99 Tcsup(m)-methylene diphosphonate and 67 Ga-citrate bone scans were performed in an attempt to discover underlying infectious process. Increased focal uptake of both radiopharmaceuticals over the same hip indicated an infectious process responsible for prosthetic loosening. There were no false positive gallium examinations. Sequential use of 99 Tcsup(m)-phosphate compounds and 67 Ga-citrate is recommended for differentiation between mechanical loosening of a prosthesis and loosening of a prosthesis secondary to an infectious process. (U.K.)

  9. The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Lin, S.-Y.; Chu, T.-C. E-mail: tcchu@mx.nthu.edu.tw; Lin, J.-P.; Liu, M.-T

    2002-07-01

    Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm{sup 2} X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD{sub Bone}, PDD{sub Ti} and PDD{sub Co}, respectively. The dose re-buildup, which occurs behind the hip region, becomes more and more obvious for denser medium existed in water. Increasing inhomogeneity also enhances the underdosage of ADAC for greater depth (>10 cm), as the figures of nearly 2% in PDD{sub Bone}, PDD{sub Ti} and 4-5% in PDD{sub Co} reveal. Overestimating the attenuated power of high-density non-water material in ADAC TPS causes this underdosage. For dose profiles, no significant differences were found in Profile{sub Bone} at any depth. Profile{sub Ti} reveals that MC slightly exceeds ADAC at off-axis position 1.0-2.0 cm. Profile{sub Co} reveals this more obviously. This finding means that scatter radiation from these denser materials is significant and cannot be predicted precisely in ADAC.

  10. [Screening with angiographic images prior to (99m)Tc-HMPAO labelled leukocyte scintigraphy in the diagnosis of periprosthetic infection].

    Science.gov (United States)

    Granados, U; Fuster, D; Soriano, A; García, S; Bori, G; Martínez, J C; Mayoral, M; Perlaza, P; Tomás, X; Pons, F

    2015-01-01

    To evaluate the impact of the angioscintigrapy of the three phase bone scan as screening method to rule out infection of the hip and knee prosthesis prior to performing the (99m)Tc-HMPAO leukocyte scintigraphy. A total of 120 (70 women, 50 men; mean age 71±11years) with clinical suspicion of hip (n=63) or knee (n=57) infection of the prosthesis and clinical suspicion of infection were evaluated prospectively. All patients underwent three-phase bone scan (angioscintigraphy, vascular and bone phase) and (99m)Tc-HMPAO-labelled white blood cell scintigraphy. Final diagnosis of infection was made by microbiological documentation or clinical follow-up for at least 12months. Eighteen out of 120 patients were diagnosed of infection of hip prosthesis (n=10) or knee prosthesis (n=8). The angioscintigraphy was positive in 15/18 infected cases and in 21/102 of the non-infected cases with a sensitivity of 83%, specificity of 79% and negative predictive value of 97%. Sensitivity and specificity of (99m)Tc-HMPAO leukocyte scintigraphy were 72% and 95%, respectively. If the leukocyte labeled scintigraphies had been used exclusively for patients with positive angioscintigraphy, this would have saved up to 70% of the (99m)Tc-HMPAO leukocyte scintigraphies performed. There were no cases of infection with positive labeled leukocyte scintigraphy and negative angioscintigraphy. Angioscintigraphy (blood flow phase of bone scan) is a useful technique for screening for hip and knee joint prosthesis infection, significantly reducing the need for (99m)Tc-HMPAO leukocyte scintigraphy without affecting the sensitivity of the technique. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  11. The Timing of Hip Arthroscopy After Intra-articular Hip Injection Affects Postoperative Infection Risk.

    Science.gov (United States)

    Wang, Dean; Camp, Christopher L; Ranawat, Anil S; Coleman, Struan H; Kelly, Bryan T; Werner, Brian C

    2017-11-01

    To evaluate the association of preoperative intra-articular hip injection with surgical site infection after hip arthroscopy. A large administrative database was used to identify all patients undergoing hip arthroscopy from 2007 to 2015 within a single private insurer and from 2005 to 2012 within Medicare in the United States. Those that received an ipsilateral preoperative intra-articular hip injection were identified. The patients were then divided into the following groups based on the interval between preoperative injection and ipsilateral hip arthroscopy: (1) 12 months) of preoperative hip injection. Patients developing a surgical site infection within 6 months following hip arthroscopy were identified using International Classification of Diseases, Ninth Revision, and Current Procedural Terminology codes associated with infection. Groups were compared using a multivariate logistic regression analysis to control for age, gender, body mass index, smoking status, alcohol usage, and multiple medical comorbidities including diabetes mellitus, hemodialysis use, inflammatory arthritis, and peripheral vascular disease. In total, 19% of privately insured and 6% of Medicare patients received a hip injection within 12 months of hip arthroscopy. The overall infection rate in privately insured and Medicare patients was 1.19% and 1.10%, respectively. Preoperative hip injection within 3 months of surgery was associated with a significantly higher risk of postoperative infection versus controls (2.16%, odds ratio [OR] 6.1, P arthroscopy increased when preoperative intra-articular hip injections were given within 3 months of surgery. Level III, retrospective comparative study. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. [Multicentre study of infection incidence in knee prosthesis].

    Science.gov (United States)

    Jaén, F; Sanz-Gallardo, M I; Arrazola, M P; García de Codes, A; de Juanes, A; Resines, C

    2012-01-01

    To determine the incidence of surgical site infection in knee prosthesis surgical procedure for a follow-up period of one year in twelve hospitals in Madrid region. A prospective study was carried out from January to December 2009 using a national surveillance system called Indicadores Clínicos de Mejora Continua de Calidad. Primary and revision knee joint replacements in patients operated on in the previous year were included. Criteria used to define surgical site infection and patient risk index categories were those established by the Centers for Disease Control and Prevention and National Nosocomial Infections Surveillance. The incidence rates were worked out crude and adjusted by hazard ratio. 2,088 knee prosthesis procedures were analyzed. The overall incidence of surgical site infection was 2.1%. Sixty-five percent of the infections were organ/space. Sixty percent of the infections were identified in the early postoperative period. Of all surgical site infections, 41.9% were microbiologically confirmed. Antibiotic prophylaxis was implemented correctly in 63.3% of the cases. The most important cause of inappropriate prophylaxis was an unsuitable duration in 85.7% of the cases. The presurgical preparation was carried out correctly in 50.3% of surgical operations. The incidence of knee arthroplasty infection was twice as high as in the National Healthcare Safety Network and similar to national rates. In this study, the incidence of infection was within the range of infection rates in other published European studies. Surveillance and control strategies of health care for associated infections allow us to assess trends and the impact of preventive measures. Copyright © 2011 SECOT. Published by Elsevier Espana. All rights reserved.

  13. Functional outcome, revision rates and mortality after primary total hip replacement--a national comparison of nine prosthesis brands in England.

    Directory of Open Access Journals (Sweden)

    Mark Pennington

    Full Text Available The number of prosthesis brands used for hip replacement has increased rapidly, but there is little evidence on their effectiveness. We compared patient-reported outcomes, revision rates, and mortality for the three most frequently used brands within each prosthesis type: cemented (Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite Plus Ogee, cementless (Corail Pinnacle, Accolade Trident, and Taperloc Exceed, and hybrid (Exeter V40 Trilogy, Exeter V40 Trilogy, and CPT Trilogy.We used three national databases of patients who had hip replacements between 2008 and 2011 in the English NHS to compare functional outcome (Oxford Hip Score (OHS ranging from 0 (worst to 48 (best in 43,524 patients at six months. We analysed revisions and mortality in 187,201 patients. We used multiple regression to adjust for pre-operative differences. Prosthesis type had an impact on post-operative OHS and revision rates (both p<0.001. Patients with hybrid prostheses had the best functional outcome (mean OHS 39.4, 95%CI 39.1 to 39.7 and those with cemented prostheses the worst (37.7, 37.3 to 38.1. Patients with cemented prostheses had the lowest reported 5-year revision rates (1.3%, 1.2% to 1.4% and those with cementless prostheses the highest (2.2%, 2.1% to 2.4%. Differences in mortality according to prosthesis type were small and not significant (p = 0.06. Functional outcome varied according to brand among cemented (p = 0.05, with Exeter V40 Duration having the best and cementless prostheses (p = 0.01, with Corail Pinnacle having the best. Revision rates varied according to brand among hybrids (p = 0.05, with Exeter V40 Trident having the lowest.Functional outcomes were better with cementless cups and revision rates were lower with cemented stems, which underlies the good overall performance of hybrids. The hybrid Exeter V40 Trident seemed to produce the best overall results. This brand should be considered as a benchmark in randomised trials.

  14. Two-stage revision surgery with preformed spacers and cementless implants for septic hip arthritis: a prospective, non-randomized cohort study

    Directory of Open Access Journals (Sweden)

    Logoluso Nicola

    2011-05-01

    Full Text Available Abstract Background Outcome data on two-stage revision surgery for deep infection after septic hip arthritis are limited and inconsistent. This study presents the medium-term results of a new, standardized two-stage arthroplasty with preformed hip spacers and cementless implants in a consecutive series of adult patients with septic arthritis of the hip treated according to a same protocol. Methods Nineteen patients (20 hips were enrolled in this prospective, non-randomized cohort study between 2000 and 2008. The first stage comprised femoral head resection, debridement, and insertion of a preformed, commercially available, antibiotic-loaded cement hip spacer. After eradication of infection, a cementless total hip arthroplasty was implanted in the second stage. Patients were assessed for infection recurrence, pain (visual analog scale [VAS] and hip joint function (Harris Hip score. Results The mean time between first diagnosis of infection and revision surgery was 5.8 ± 9.0 months; the average duration of follow up was 56.6 (range, 24 - 104 months; all 20 hips were successfully converted to prosthesis an average 22 ± 5.1 weeks after spacer implantation. Reinfection after total hip joint replacement occurred in 1 patient. The mean VAS pain score improved from 48 (range, 35 - 84 pre-operatively to 18 (range, 0 - 38 prior to spacer removal and to 8 (range, 0 - 15 at the last follow-up assessment after prosthesis implantation. The average Harris Hip score improved from 27.5 before surgery to 61.8 between the two stages to 92.3 at the final follow-up assessment. Conclusions Satisfactory outcomes can be obtained with two-stage revision hip arthroplasty using preformed spacers and cementless implants for prosthetic hip joint infections of various etiologies.

  15. MRSA-Infected External Iliac Artery Pseudoaneurysm Treated with Endovascular Stenting

    International Nuclear Information System (INIS)

    Clarke, M.G.; Thomas, H.G.; Chester, J.F.

    2005-01-01

    A 48-year-old woman with severe juvenile-onset rheumatoid arthritis presented with a bleeding cutaneous sinus distal to her right total hip replacement scar. Methicillin resistant Staphylococcus aureus (MRSA) was isolated on culture. She had previously undergone bilateral total hip and knee replacements at aged 23 and six years later had the right knee prosthesis removed for infection, with subsequent osteomyelitis of the femoral shaft and right total hip prosthesis disruption. Peripheral arteriography was performed in view of persistent bleeding from the sinus, which revealed a 6 cm false aneurysm filling from and compressing the right external iliac artery (EIA). A PTFE-covered, balloon expandable JOSTENT was deployed in the right EIA, successfully excluding the false aneurysm and preventing further bleeding from the sinus. No graft infection was reported at 12 months. This case illustrates the potential use of endovascular stent-grafting in the treatment of an infected pseudoaneurysm

  16. Assessment of suspected infection of hip or knee endoprosthesis by nuclear medicine techniques; Nuklearmedizinische Abklaerung bei vermuteter Infektion einer Hueft- oder Knie-TEP

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, M.; Dietlein, M.; Schicha, H. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin; Delank, K.S. [Koeln Univ. (Germany). Klinik und Poliklinik fuer Orthopaedie

    2007-06-15

    Complications after hip endoprosthesis operation occur with a frequency of 1-2 % after primary operation and with 3-5 % after revision arthroplasty and are even more frequent after knee arthroplasty. The differentiation between aseptic loosening and bacterial infection is very important. In aseptic loosening a one-step revision is usually possible. In case of bacterial infection, all foreign material has to be removed first to allow cure from the infection. After healing and absence of bacteria a follow-up operation is possible with insertion of a new prosthesis. Diagnosis and therapy of a painful hip or knee endoprosthesis are difficult, because patient history, clinical examination, laboratory results including microbiological investigation of puncture material and results of radiological examinations may all be inconclusive. Quite a number of nuclear medicine procedures have been published in the past to help in the differentiation between aseptic loosening and bacterial infection of a painful hip or knee endoprosthesis. No single method can be regarded as excellent and without disadvantages. In the international literature the combined leucocyte-marrow imaging has been propageted as superior technique. In Germany, combined leucocyte-marrow imaging is not available in the published form. Moreover, this technique is time consuming, cost intensive and requires direct work with blood. Therefore, infection imaging with labelled antibodies or labelled fragments of antibodies may be regarded as the method of choice for most nuclear medicine physicians. With semiquantitative evaluation a comparative diagnostic accuracy may be achieved. {sup 18}F-FDG-PET is not able to differentiate reliably between abacterial polyethylene abrasion and septic inflammation. However, with pattern recognition of the distribution of {sup 18}F-FDG around a hip prosthesis an approach with clinically acceptable results has been published. A normal {sup 18}F-FDG-PET can reliably exclude an

  17. Silver-coated dacron prosthesis in the treatment of infection in arterial surgery: Case reports

    Directory of Open Access Journals (Sweden)

    Nenezić Dragoslav

    2008-01-01

    Full Text Available INTRODUCTION Although the incidence is low, infection of prosthetic vascular graft bears a high incidence of serious complications including 25-75% mortality rate and 40-75% limb loss. The standard treatment of vascular graft infection consists of excision of the prosthesis, wound debridement and extraanatomic revascularization. Conservative treatment might be an option in a limited number of patients. We present three cases of surgical and conservative treatment of vascular graft infection. CASE OUTLINE Case 1: A patient developed silver-coated graft infection after femorodistal arterial reconstruction performed because of critical limb ischemia. In the early postoperative period, massive skin and subcutaneous tissue necrosis developed, with the graft being exposed. After two months of persistent debridement and wound toilette, the defect was covered with a Thiersch skin graft. Case 2: PTFE graft infection in the right groin followed reconstruction of the isolated common femoral artery aneurysm. This graft was replaced with a silver-coated graft in situ. Reinfection of the proximal end of the implanted silver-coated graft occurred and the graft was exposed. After repeated debridement and wound toilette, the exposed prosthesis was covered with granulomatous tissue, and the wound healed. Case 3: A year after anastomotic pseudoaneurysm resection in the left groin, prosthesis was exposed following wound infection. This graft was substituted with a silver-coated graft in situ. The wound healed primarily. CONCLUSION These three cases demonstrate that under some circumstances vascular prosthesis infection can be successfully treated conservatively without graft removal, and also by in situ replacement using silver-coated graft.

  18. Successful staged hip replacement in septic hip osteoarthritis in osteopetrosis: a case report

    Directory of Open Access Journals (Sweden)

    Manzi Giovanni

    2012-04-01

    Full Text Available Abstract Background Osteopetrosis is a rare, inherited, bone disorder, characterized by osteosclerosis, obliteration of the medullary cavity and calcified cartilage. The autosomal dominant form is compatible with a normal life span, although fractures often result from minimal trauma, due to the pathologic nature of bone. Osteomyelitis is common in patients with osteopetrosis because of a reduced resistance to infection, attributed to the lack of marrow vascularity and impairment of white cell function. Only one case of osteomyelitis of the proximal third of the femur has been previously reported, treated with several repeated debridements and finally with femoral head resection. Here we present for the first time a case of a staged implant of a cementless total hip prosthesis for the treatment of a septic hip in femoral neck nonunion in osteopetrosis. Case presentation A 36-years-old woman, affected by autosomal dominant osteopetrosis was referred to our department because of a septic hip arthritis associated with femoral neck septic non-union, with draining fistulas. The infection occurred early after a plate osteosynthesis for a closed perthrocanteric fracture of the femur and persisted in spite of osteosynthesis removal, surgical debridement and external fixation. In our hospital the patient underwent accurate debridement, femoral head and greater trochanter resection, preparation of the diaphyseal intramedullary canal and implant of an antibiotic-loaded cement spacer. The spacer was exchanged after one month, due to infection recurrence and four months later, a cementless total hip arthroplasty was implanted, with no clinical and laboratory signs of infection recurrence at two years follow-up. Conclusions In case of hip septic arthritis and proximal femur septic non-union, femoral head resection may not be the only option available and staged total hip arthroplasty can be considered.

  19. Hospital ownership: a risk factor for nosocomial infection rates?

    Science.gov (United States)

    Schröder, C; Behnke, M; Geffers, C; Gastmeier, P

    2018-03-26

    In some countries, a relationship between hospital ownership and the occurrence of healthcare-associated infection (HCAI) rates has been described. To investigate the association between hospital ownership and occurrence of HCAI in Germany. Five different components of the German national nosocomial infection surveillance system were analysed with regard to the influence of hospital ownership in the period 2014-2016. Endpoints included ventilator-associated pneumonia, central-venous-catheter-associated bloodstream infections, urinary-catheter-associated urinary tract infections, surgical site infections (SSI) following hip prosthesis and colon surgery, meticillin-resistant Staphylococcus aureus (MRSA), Clostridium difficile infections (CDI) and hand rub consumption per 1000 patient-days. Three hospital ownership types (public, non-profit and private) were analysed using univariate and multi-variate methods. The distribution of hospitals according to the three ownership types was similar in all components. In total, 661 intensive care units (ICUs), 149 departments performing colon procedures, and 349 departments performing hip prosthesis were included. In addition, 568 hospitals provided their MRSA rates and 236 provided their CDI rates, and 1833 ICUs and 12,934 non-ICUs provided their hand rub consumption data. In general, the differences between the hospital types were rather small and not significant for the ICUs. In the multi-variate analysis, public hospitals had a lower SSI rate following hip prosthesis (odds ratio 0.80, 95% confidence interval 0.65-0.99). Hospital ownership was not found to have a major influence on the incidence of HCAI in Germany. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  20. An Insight into Methods and Practices in Hip Arthroplasty in Patients with Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Mohammad Saeed Mosleh-shirazi

    2015-01-01

    Full Text Available Total hip arthroplasty (THA has improved the quality of life of patients with hip arthritis. Orthopedic community is striving for excellence to improve surgical techniques and postoperative care. Despite these efforts, patients continue facing postoperative complications. In particular, patients with rheumatoid arthritis display a higher risk of certain complications such as dislocation, periprosthetic infection, and shorter prosthesis durability. In this review we present the current knowledge of hip arthroplasty in patients with rheumatoid arthritis with more insight into common practices and interventions directed at enhancing recovery of these patients and current shortfalls.

  1. [Total hip arthroplasty in post-dysplastic hip arthritis. Can type and position of the acetabular component influence longevity of the prosthesis?].

    Science.gov (United States)

    Fousek, J; Indráková, P

    2007-02-01

    The aim of the study was a retrospective evaluation of our patients with post-dysplastic hips treated by cemented or non-cemented total hip arthroplasty (THA) in order to ascertain which type and position of the acetabular component was most effective. In the years 1999-2002, 111 THA procedures were performed in 93 patients, 76 women and 17 men, with post-dysplastic hip arthritis. The average age of the patients at the time of implantation was 52.6 years. On the basis of pre-operative radiographic findings, the patients' conditions were evaluated using the Hartofilakidis classification into three disease categories: dysplasia, low dislocation and high dislocation, and the patients were placed in two groups. Group 1 included 78 patients, and group 2 comprised 26 patients. None of our patients was classified as having high dislocation. Thirty-nine of these patients had previously undergone surgery for dysplastic hips. A total of 104 THAs were evaluated, because radiographic data was incomplete in seven cases. In addition to X-ray findings, the prosthesis type (cemented, hybrid, non-cemented), post-operative complications and signs of loosening were included in the evaluation. Clinical outcomes were assessed by the Harris score. The follow-up terminating on 31st December 2005 was 67 months on the average. In group 1 patients, the average Harris score increased from 38.6 to 80.3 points and in group 2 patients from 35.5 to 84.9 points, mostly with excellent and good results. In 72.1 % of the hips, a press-fit acetabular component was implanted. In 55.8 % of the cases, the acetabular component was implanted off the anatomical center of rotation, into the high hip center, with the range from 9 to 20 mm and an average of 15 mm. The average limb lengthening was 2.5 cm, ranging from 1.0 to 3.5 cm. Our results show that it is more effective to use non-cemented THA for post-dysplastic hips. The implantation of a noncemented acetabular component into the high center provides

  2. Indications of {sup 99m}Tc-MDP scintigraphy bone scan in the evaluation of painful hip arthroplasties; Place actuelle de la scintigraphie osseuse dans l'evaluation des protheses de hanches douloureuses

    Energy Technology Data Exchange (ETDEWEB)

    Eder, V.; Baulieu, F.; Secchi, V.; Gautier, B.; Pottier, J.M. [Centre Hospitalier Universitaire, Sce de Medecine Nucleaire et Echographie, 37 - Tours (France); Rosset, P. [Centre Hospitalier Universitaire, Sce de Chirurgie Orthopedique et Traumatologique, 37 - Tours (France)

    2000-01-01

    The purpose of this study was to determine the indication of bone scintigraphy in hip prosthesis complications. Thirty-six patients and 38 hip prosthesis have had a {sup 99}Tc-MDP scintigraphy in our laboratory between 1995 and 1997. It concerns 32 cemented total prosthesis, 3 intermediate prosthesis and 3 non-cemented total prosthesis. For 14 prosthesis, complication (loosening or infection) was confirmed by surgical operation in 12 cases (4 isolated acetabular complications, 2 isolated femoral loosening, 3 global loosening and 3 infections) or by concordant data from different examinations in 2 cases (global loosening) where intervention was unrealizable. About other patients, absence of complication was confirmed by a favourable evolution lasting at least 12 months. A cetabular and femoral complications were detected by scintigraphy respectively with a sensitivity of 100 % and 90 %, a specificity of 85 % and 78 %, a PPV of 75 % and 60 % and NPV of 100 % and 96 %. High negative predictive value allows to eliminate a prosthesis complication in the case of a normal scintigraphy and to override decision when the clinic and the radiography are doubtful. Scintigraphy may recognize other bone fixation abnormalities which may be responsible of clinical symptomatology. (authors)

  3. Hip disarticulation - case series analysis and literature review

    Directory of Open Access Journals (Sweden)

    Diogo Lino Moura

    Full Text Available ABSTRACT OBJECTIVE: To present a retrospective study of 16 patients submitted to hip disarticulation. METHODS: During the period of 16 years, 16 patients who underwent hip disarticulation were identified. All of them were studied based on clinical records regarding the gender, age at surgery, disarticulation cause, postoperative complications, mortality rates and functional status after hip disarticulation. RESULTS: Hip disarticulation was performed electively in most cases and urgently in only three cases. The indications had the following origins: infection (n = 6, tumor (n = 6, trauma (n = 3, and ischemia (n = 2. The mean post-surgery survival was 200.5 days. The survival rates were 6875% after six months, 5625% after one year, and 50% after three years. The mortality rates were higher in disarticulations with traumatic (66.7% and tumoral (60% causes. Regarding the eight patients who survived, half of them ambulate with crutches and without prosthesis, 25% walk with limb prosthesis, and 25% are bedridden. Complications and mortality were higher in the cases of urgent surgery, and in those with traumatic and tumoral causes. CONCLUSION: Hip disarticulation is a major ablative surgery with obvious implications for limb functionality, as well as high rates of complications and mortality. However, when performed at the correct time and with proper indication, this procedure can be life-saving and can ensure the return to the home environment with a certain degree of quality of life.

  4. Bone-preserving total hip arthroplasty in avascular necrosis of the hip-a matched-pairs analysis.

    Science.gov (United States)

    Merschin, David; Häne, Richard; Tohidnezhad, Mersedeh; Pufe, Thomas; Drescher, Wolf

    2018-07-01

    Short-stem hip arthroplasty has the potential advantage of femoral bone stock preservation, especially in view of the expected revisions in the often relatively young patients. Despite short-stem hip prosthesis are increasingly used for total hip arthroplasty, there are no sufficient mid- and long-term results especially for patients with avascular femoral head osteonecrosis. The present study investigates mid-term functional results as well as the revision rate following implantation of a short-stem prosthesis. In the period 06/2005 until 12/2013, a total of 351 short-stem hip prostheses were implanted. The study included 331 complete data sets. A retrospective analysis was performed using the Oxford Hip Score. All revisions were registered. In a total of 331 prostheses, the Oxford Hip Score was "excellent" in 66.2%, "good" in 12.7%, "fair" in 13.0%, and "poor" in 8.2% with a mean follow-up of 57.4 months (SD ± 29.8; range 24-115). In 26 cases, aseptic osteonecrosis of the hip was the indication (7.9%). The Oxford Hip Score was "excellent" in 66.7%, "good" in 0.0%, "fair" in 20.8%, and "poor" in 12.5%. The cumulated five year survival rate was 96.7%. In mid-term observation, the Metha® short-stem prosthesis shows no disadvantage in functional outcome and in survival time compared to a standard hip stem. Providing a correct indication, the Metha® short stem is a valuable option in total hip arthroplasty for younger patients with avascular osteonecrosis of the femoral head. Evaluation has shown no significant differences between aseptic osteonecrosis and other indications.

  5. Pseudotumor of the Hip due to Fungal Prosthetic Joint Infection

    Directory of Open Access Journals (Sweden)

    Stefano Artiaco

    2013-01-01

    Full Text Available Pseudotumors associated with total hip arthroplasty have been associated with metal-on-metal and metal-on-polyethylene total hip arthroplasties due to a granulomatous foreign-body reaction to methyl methacrylate, polyethylene, or metal ion release, but they have not been related to prosthetic joint infections. In this paper, we report an unusual case of Candida albicans total hip arthroplasty infection, causing a large inflammatory pseudotumor of the hip joint. Fungal periprosthetic joint infections are a rare clinical entity and difficult to diagnose, and a pseudotumor may be part of their clinical presentation. They should be suspected in immunodeficient host patients when clinical symptoms of prosthetic joint infections are observed.

  6. Good quality of life outcomes after treatment of prosthetic joint infection with debridement and prosthesis retention.

    Science.gov (United States)

    Aboltins, Craig; Dowsey, Michelle; Peel, Trish; Lim, Wen K; Choong, Peter

    2016-05-01

    Patients treated for early prosthetic joint infection (PJI) with surgical debridement and prosthesis retention have a rate of successful infection eradication that is similar to patients treated with the traditional approach of prosthesis exchange. It is therefore important to consider other outcomes after prosthetic joint infection treatment that may influence management decisions, such as quality of life (QOL). Our aim was to describe infection cure rates and quality of life for patients with prosthetic joint infection treated with debridement and prosthesis retention and to determine if treatment with this approach was a risk factor for poor quality of life outcomes. Prospectively collected pre and post-arthroplasty data were available for 2,134 patients, of which PJI occurred in 41. For patients treated for prosthetic joint infection, the 2-year survival free of treatment failure was 87% (95%CI 84-89). Prosthetic joint infection cases treated with debridement and retention had a similar improvement from pre-arthroplasty to 12-months post-arthroplasty as patients without PJI in QOL according to the SF-12 survey. Prosthetic joint infection treated with debridement and retention was not a risk factor for poor quality of life on univariate or multivariate analysis. Prosthetic joint infection treated with debridement and prosthesis retention results in good cure rates and quality of life. Further studies are required that directly compare quality of life for different surgical approaches for prosthetic joint infection to better inform management decisions. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:898-902, 2016. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. Modified cementless total coxofemoral prosthesis: development, implantation and clinical evaluation

    Directory of Open Access Journals (Sweden)

    S.A. Arias

    2013-12-01

    Full Text Available The aim of this study was to modify canine coxofemoral prostheses and the clinical evaluation of the implantation. Fifteen canine hips and femora of cadavers were used in order to study the surface points of modification in prostheses and develop a perforation guide. Femoral stems and acetabular components were perforated and coated with biphasic calcium phosphate layer. Twelve young adult male mongrel dogs were implanted with coxofemoral prostheses. Six were operated upon and implanted with cemented canine modular hip prostheses, establishing the control group. The remaining six were implanted with a novel design of cementless porous tricalcic phosphate-hydroxyapatite coated hip prostheses. Clinical and orthopedic performance, complications, and thigh muscular hypotrophy were assessed up to the 120th post-operatory day. After 120 days, animals with cementless prostheses had similar clinical and orthopedic performance compared to the cemented group despite the increased pain thigh hypotrophy. Animals that underwent cementless hip prosthesis evidenced more pain, compared to animals with cemented hip prosthesis that required longer recuperation time. No luxations, two fractures and two isquiatic neurapraxies were identified in the course of the study. Using both the cemented and the bioactive coated cementless model were suitable to dogs, showing clinical satisfactory results. Osseointegration and biological fixation were observed in the animals with the modified cementless hip prosthesis.

  8. Clinical usage of indium-111 labeled leukocyte scintigraphy and technetium-99m methylene diphosphonate scintigraphy in patients with total hip replacement

    International Nuclear Information System (INIS)

    Terauchi, Takashi; Uno, Kimiichi; Yuyama, Takuo; Seto, Kazuhiko; Arimizu, Noboru; Suguro, Tohru; Moriya, Hideshige; Uematsu, Sadao.

    1988-01-01

    Tc-99m methylene diphosphonate (MDP) scintigraphy and In-111 labeled leukocyte scintigraphy were done in 13 patients with total hip replacement in order to determine the presence of prosthetic infection. Tc-99m MDP scintigraphy was done in 11 patients (12 studies). In-111 labeled leukocyte scintigraphy was done in 13 patients (14 studies). Tc-99m MDP imaging showed diffuse accumulation of the radionuclide in all of the 3 infected lesions, but focal one in 5 of the 7 noninfected lesions with a specificity of 33.3 %, sensitivity of 100 %, overall accuracy of 50 %. In-111 labeled leukocyte normally accumulates in the spleen, the liver, and the bone marrow. Before insertion of a stemmed prosthesis, the local bone marrows were reamed out in all of our cases. Thus, no radioactive accumulation would be expected in the lesions with prosthesis unless infected. However, if the prosthesis is infected, increased uptake of In-111 would be seen as a result of the accumulation of leukocyte. In-111 labeled leukocyte imaging showed abnormal accumulation of In-111 in all of the 4 infected lesions and no accumulation in all of the 10 noninfected lesions with a specificity of 100 %, sensitivity of 100 %, overall accuracy of 100 %. We conclude that In-111 labeled leukocyte scintigraphy might be useful in evaluating prosthetic infection in a patient with total hip replacement. (author)

  9. Total hip prosthesis complication, periprosthetic infection with external fistulizing due to Enterobacter cloacae complex multiple drugs resistance: A clinical case report

    Directory of Open Access Journals (Sweden)

    V. Amorese

    2017-01-01

    Conclusion: The patient was hospitalized in our facility and 2 months later she underwent another operation to remove the antibiotic spacer and to place a new total hip arthroprosthesis. Multiple swabs showed the complete healing from the infection, which was confirmed a couple of months later.

  10. Treatment of femoral neck fracture by Moore Prosthesis in Cotonou ...

    African Journals Online (AJOL)

    Treatment of femoral neck fracture by Moore Prosthesis in Cotonou. AHM Akue, M Lawson, S Madougou, R Zannou, J Padonou. Abstract. Keywords: Benin; hip; Moore prosthesis; results. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT.

  11. Revision of failed hip resurfacing to total hip arthroplasty rapidly relieves pain and improves function in the early post operative period

    Directory of Open Access Journals (Sweden)

    Muirhead-Allwood Sarah K

    2010-11-01

    Full Text Available Abstract We reviewed the results of 25 consecutive patients who underwent revision of a hip resurfacing prosthesis to a total hip replacement. Revisions were performed for recurrent pain and effusion, infection and proximal femoral fractures. Both components were revised in 20 cases. There were 12 male and 13 female patients with average time to revision of 34.4 and 26.4 months respectively. The mean follow up period was 12.7 months (3 to 31. All patients reported relief of pain and excellent satisfaction scores. Two patients experienced stiffness up to three months post operatively. Pre operative Oxford, Harris and WOMAC hip scores were 39.1, 36.4 and 52.2 respectively. Mean post operative scores at last follow up were 17.4, 89.8 and 6.1 respectively (p

  12. Monte Carlo dose calculations for phantoms with hip prostheses

    International Nuclear Information System (INIS)

    Bazalova, M; Verhaegen, F; Coolens, C; Childs, P; Cury, F; Beaulieu, L

    2008-01-01

    Computed tomography (CT) images of patients with hip prostheses are severely degraded by metal streaking artefacts. The low image quality makes organ contouring more difficult and can result in large dose calculation errors when Monte Carlo (MC) techniques are used. In this work, the extent of streaking artefacts produced by three common hip prosthesis materials (Ti-alloy, stainless steel, and Co-Cr-Mo alloy) was studied. The prostheses were tested in a hypothetical prostate treatment with five 18 MV photon beams. The dose distributions for unilateral and bilateral prosthesis phantoms were calculated with the EGSnrc/DOSXYZnrc MC code. This was done in three phantom geometries: in the exact geometry, in the original CT geometry, and in an artefact-corrected geometry. The artefact-corrected geometry was created using a modified filtered back-projection correction technique. It was found that unilateral prosthesis phantoms do not show large dose calculation errors, as long as the beams miss the artefact-affected volume. This is possible to achieve in the case of unilateral prosthesis phantoms (except for the Co-Cr-Mo prosthesis which gives a 3% error) but not in the case of bilateral prosthesis phantoms. The largest dose discrepancies were obtained for the bilateral Co-Cr-Mo hip prosthesis phantom, up to 11% in some voxels within the prostate. The artefact correction algorithm worked well for all phantoms and resulted in dose calculation errors below 2%. In conclusion, a MC treatment plan should include an artefact correction algorithm when treating patients with hip prostheses

  13. Morphological experimental study of bone stress at the interface acetabular bone/prosthetic cup in the bipolar hip prosthesis.

    Science.gov (United States)

    Anuşca, D; Pleşea, I E; Iliescu, N; Tomescu, P; Poenaru, F; Dascălu, V; Pop, O T

    2006-01-01

    By calculating the tension and distortion of the elements composing the bipolar prosthesis under extreme conditions encountered in real life using a special post-processing program, we established the variation curves of the contact pressure at the hip bone-cup, armor-cup and cup-femoral head interface. By comparing the data obtained from all the examined cases, important conclusions were drawn regarding the influence of tension and pressure distribution on the structural integrity and biomechanics of the prosthesis, as well as the acetabular wear and tear, in order to assess its reliability. The experimentally determined tension and distortion status at the acetabular bone-metal armour interface, lead to the wear and tear phenomenon, which can be explained by three mechanisms and theories incompletely reflecting the overall process. The histopathologic study of the acetabular bone tissue using FEM (finite elements method) on surgically removed specimens will probably lead to the identification of a series of factors that could reduce the rate of the wear and tear process.

  14. Total hip replacement infected with Mycobacterium tuberculosis complicated by Addison disease and psoas muscle abscess: a case report

    Directory of Open Access Journals (Sweden)

    De Nardo Pasquale

    2012-01-01

    Full Text Available Abstract Introduction Prosthetic joint infection due to Mycobacterium tuberculosis is occasionally encountered in clinical practice. To the best of our knowledge, this is the first report of a prosthetic joint infection due to Mycobacterium tuberculosis complicated by psoas abscesses and secondary Addison disease. Case presentation A 67-year-old immunocompetent Caucasian woman underwent total left hip arthroplasty because of osteoarthritis. After 18 months, she underwent arthroplasty revision for a possible prosthetic infection. Periprosthetic tissue specimens for bacteria were negative, and empirical antibiotic therapy was unsuccessful. She was then admitted to our department because of complications arising 22 months after arthroplasty. A physical examination revealed a sinus tract overlying her left hip and skin and mucosal pigmentation. Her levels of C-reactive protein, basal cortisol, adrenocorticotropic hormone, and sodium were out of normal range. Results of the tuberculin skin test and QuantiFERON-TB Gold test were positive. Computed tomography revealed a periprosthetic abscess and the inclusion of the left psoas muscle. Results of microbiological tests were negative, but polymerase chain reaction of a specimen taken from the hip fistula was positive for Mycobacterium tuberculosis. Our patient's condition was diagnosed as prosthetic joint infection and muscle psoas abscess due to Mycobacterium tuberculosis and secondary Addison disease. She underwent standard treatment with rifampicin, ethambutol, isoniazid, and pyrazinamide associated with hydrocortisone and fludrocortisone. At 15 months from the beginning of therapy, she was in good clinical condition and free of symptoms. Conclusions Prosthetic joint infection with Mycobacterium tuberculosis is uncommon. A differential diagnosis of tuberculosis should be considered when dealing with prosthetic joint infection, especially when repeated smears and histology examination from infected

  15. Should gram stains have a role in diagnosing hip arthroplasty infections?

    Science.gov (United States)

    Johnson, Aaron J; Zywiel, Michael G; Stroh, D Alex; Marker, David R; Mont, Michael A

    2010-09-01

    The utility of Gram stains in diagnosing periprosthetic infections following total hip arthroplasty has recently been questioned. Several studies report low sensitivity of the test, and its poor ability to either confirm or rule out infection in patients undergoing revision total hip arthroplasty. Despite this, many institutions including that of the senior author continue to perform Gram stains during revision total hip arthroplasty. We assessed the sensitivity, specificity, accuracy, and positive and negative predictive values of Gram stains from surgical-site samplings taken from procedures on patients with both infected and aseptic revision total hip arthroplasties. A review was performed on patients who underwent revision total hip arthroplasty between 2000 and 2007. Eighty-two Gram stains were performed on patients who had infected total hip arthroplasties and underwent revision procedures. Additionally, of the 410 revision total hip arthroplasties performed on patients who were confirmed infection-free, 120 Gram stains were performed. Patients were diagnosed as infected using multiple criteria at the time of surgery. Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated from these Gram stain results. The Gram stain demonstrated a sensitivity and specificity of 9.8% and 100%, respectively. In this series, the Gram stain had a negative predictive value of 62%, a positive predictive value of 100%, and an accuracy of 63%. Gram stains obtained from surgical-site samples had poor sensitivity and poor negative predictive value. Based on these findings, as well as those of other authors, we believe that Gram stains should no longer be considered for diagnosing infections in revision total hip arthroplasty. Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.

  16. Sonographic findings after total hip arthroplasty: normal and complications

    International Nuclear Information System (INIS)

    Lee, Kyoung Rok; Seon, Young Seok; Choi, Ji He; Kim, Sun Su; Kim, Se Jong; Park, Byong Lan; Kim, Byoung Geun

    2002-01-01

    The purpose of this study was to determine the efficacy of sonography in the evaluation of normal pseudocapsular morphology and the detection of complications after total hip arthroplasty. Between Janvary 1997 and June 2000, 47 patients (35 men and 12 women aged 24 to 84 (mean, 61) years) using real-time linear-array, convex US units with 3.5-MHz and 10-MHz transducers. Normal capsular morphology in 30 with total hip replacements, who had been asymptomatic for at least one year, was studied, and the prosthetic joint infection demonstrated in six of 17 who had experienced was confirmed at surgery or by US-guided aspiration. Sonograms indicated that a normal pseudocapsule lay straight over the neck of the prosthesis or was slightly convex toward the neck , and that the mean bone-to-pseudocapsule distance was 2.9 mm. However, in the 11 symptomatic patients in whom no evidence of infection was revealed by cultures, th mean distance was 4.7 mm; in the remaining six patients, whose joints were infected (a condition strongly suggested by the presence of extracapsular fluid), the mean distance was 5.5 mm, with no significant difference between the two groups. Sonography can be used to evaluate normal caspular morphology after total hip replacement and to diagnose infection around hip prostheses. In all patients in whom sonography revealed the presence of extra-articular fluid, infection had occurred

  17. Sonographic findings after total hip arthroplasty: normal and complications

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyoung Rok; Seon, Young Seok; Choi, Ji He; Kim, Sun Su; Kim, Se Jong; Park, Byong Lan; Kim, Byoung Geun [Kwangju Christian Hospital, Kwangju (Korea, Republic of)

    2002-04-01

    The purpose of this study was to determine the efficacy of sonography in the evaluation of normal pseudocapsular morphology and the detection of complications after total hip arthroplasty. Between Janvary 1997 and June 2000, 47 patients (35 men and 12 women aged 24 to 84 (mean, 61) years) using real-time linear-array, convex US units with 3.5-MHz and 10-MHz transducers. Normal capsular morphology in 30 with total hip replacements, who had been asymptomatic for at least one year, was studied, and the prosthetic joint infection demonstrated in six of 17 who had experienced was confirmed at surgery or by US-guided aspiration. Sonograms indicated that a normal pseudocapsule lay straight over the neck of the prosthesis or was slightly convex toward the neck , and that the mean bone-to-pseudocapsule distance was 2.9 mm. However, in the 11 symptomatic patients in whom no evidence of infection was revealed by cultures, th mean distance was 4.7 mm; in the remaining six patients, whose joints were infected (a condition strongly suggested by the presence of extracapsular fluid), the mean distance was 5.5 mm, with no significant difference between the two groups. Sonography can be used to evaluate normal caspular morphology after total hip replacement and to diagnose infection around hip prostheses. In all patients in whom sonography revealed the presence of extra-articular fluid, infection had occurred.

  18. Primary cemented total hip arthroplasty: 10 years follow-up

    Directory of Open Access Journals (Sweden)

    Nath Rajendra

    2010-01-01

    Full Text Available Background: Primary cemented total hip arthroplasty is a procedure for non-traumatic and traumatic affections of the hip. Long term follow-up is required to assess the longevity of the implant and establish the procedure. Indo-Asian literature on long term result of total hip arthroplasty is sparse. We present a 10-year follow-up of our patients of primary cemented total hip arthroplasty. Materials and Methods: We operated 31 hips in 30 patients with primary cemented total hip arthroplasty. We followed the cases for a minimum period of 10 years with a mean follow-up period of 12.7 years. The mean age of the patients was 60.7 years (range 37-82 yrs male to female ratio was 2:1. The clinical diagnoses included - avascular necrosis of femoral head (n=15, sero positive rheumatoid arthritis (n=5, seronegative spondylo-arthropathy (n=4, neglected femoral neck fractures (n=3, healed tubercular arthritis (n=2 and post traumatic osteoarthritis of hip (n=2. The prostheses used were cemented Charnley′s total hip (n=12 and cemented modular prosthesis (n=19. The results were assessed according to Harris hip score and radiographs taken at yearly intervals. Results: The mean follow-up is 12.7 yrs (range 11-16 yrs Results in all operated patients showed marked improvement in Harris hip score from preoperative mean 29.2 to 79.9 at 10 years or more followup. However, the non-inflammatory group showed more sustained long term improvement as compared to the inflammatory group, as revealed by the Harris hip score. Mean blood loss was 450ml (±3.7 ml, mean transfusion rate was 1.2 units (±.3. The complications were hypotension (n=7, shortening> 1.5 cm (n=9, superficial infection (n=2 and malposition of prosthesis (n=1. Conclusion: The needs of Indian Asian patients, vary from what is discussed in literature. The pain tolerance is greater than western population and financial constraints are high. Thus revision surgery among Indian-Asian patients is less compared

  19. Partial-limb salvage after persistent infection in the distal femoral prosthesis: straight-plasty - a novel technique

    International Nuclear Information System (INIS)

    Kundu, Z. S.; Gupta, V.; Gogna, P.

    2014-01-01

    A 35 years old female had giant cell tumour (GCT) of the distal femur for which wide resection and distal femoral endoprosthetic replacement was performed. Massive infection of prosthesis required removal and replacement of the prosthesis with nail antibiotic cement spacer, which also proved to be futile. Ultimately the whole of the infected thigh had to be excised. The limb could be preserved partially using straight-plasty instead of amputation. Patient is well rehabilitated and doing well at a follow-up of 3 years. (author)

  20. Routine one-stage exchange for chronic infection after total hip replacement.

    Science.gov (United States)

    Jenny, Jean-Yves; Lengert, Régis; Diesinger, Yann; Gaudias, Jeannot; Boeri, Cyril; Kempf, Jean-François

    2014-12-01

    We hypothesized that a routine one-stage exchange for treatment of chronically infected total hip replacement (THR) will lead to (1) a higher rate of infection recurrence and (2) a poorer hip outcome than the published rates after two-stage exchange. Sixty-five cases have been treated consecutively with one-stage exchange. All patients have been followed for a period of three to six years or until death or infection recurrence. The five-year rate for infection recurrence was 16%. The five-year survival rate for recurrence of the index infection was 8%. Forty-two percent of the hips had a good or excellent PMA score, and 46% a good or excellent OH score. Routine one-stage exchange was not associated with a higher recurrence rate and a poorer hip function than previously published series of two-stage exchange. Therefore, there is little support to choose two-stage exchange as the routine treatment for management of chronically infected THR.

  1. Assessment of the accumulation of technetium-99m labelled leukocytes in the treatment of the infections of vascular prosthesis

    International Nuclear Information System (INIS)

    Pupka, A.; Kaluza, G.; Skora, J.; Szyber, P.; Rynowiecka, M.

    2003-01-01

    The purpose of this is to evaluate the accumulation of technetium-99m-labelled leukocytes after change of vascular, dacron and infected prosthetic graft in arterial homo grafts harvested from multiorgan-procurement - with own computer program. In this paper 11 cases of aorto-ilio-femoral graft infection treated by the replacement of infected prosthesis with fresh, bifurcated, arterial homografts is presented. In all patients clinical investigations revealed vascular prosthesis infection with the rupture of vascular anastomoses between the prosthesis' branch and wall of artery that resulted with hemorrhage. The Duplex- Doppler ultrasound and the scintigraphy with use of technetium-labeled leucocytes were used in the diagnostic trial of infection and of the healing process of the arterial homografts.The area of the accumulation of 99m Tc labelled leukocytes was evaluated with own computer programs. Positive clinical effect was obtained in all patients.The regression of infection after in situ replacement of the synthetic prosthesis with homograft was presented with the scintigraphic examination: in these patients the area of leukocytes accumulation decreased from 34±3 cm 2 to 9±2cm 2 . The use of scintigraphy with 99m Tc labelled leukocytes to evaluate the healing process of the arterial homografts in therapy of the prosthetic graft is a the accumulation of leucocytes is facilitation in the monitoring of regression of infection. (author)

  2. One-stage revision of infected hip arthroplasty: outcome of 39 consecutive hips.

    Science.gov (United States)

    Ilchmann, Thomas; Zimmerli, Werner; Ochsner, Peter Emil; Kessler, Bernhard; Zwicky, Lukas; Graber, Peter; Clauss, Martin

    2016-05-01

    There are various options for treating periprosthetic joint infection (PJI). Two-stage exchange has traditionally been the gold standard. However, if the appropriate surgical intervention is chosen according to a rational algorithm, the outcome is similar when using all types of interventions. In an observational cohort study, the outcome of patients with PJI after hip replacement treated with one-stage revision was analysed. All patients fulfilling all criteria for one-stage exchange according to the Infectious Diseases Society of America (IDSA) guidelines and six without preoperative identification of a microorganism were included. Implant removal, debridement and cemented or uncemented reimplantations were performed in a single intervention. If a cemented device was implanted, commercially available gentamicin cement was used in all cases. Antibiotic treatment was administered intravenously for at least 2 weeks, followed by oral therapy for a total duration of 3 months. Patients had standardised clinical and radiological follow-up visits. Between 1996 and 2011, 38 patients (39 hips) were treated with a one-stage procedure and followed for at least 2 years. Coagulase-negative staphylococci were the most frequent pathogens, and polymicrobial infection was observed in five cases. In 25 hips, an uncemented revision stem was implanted, and 37 hips received an acetabular reinforcement ring. The mean follow-up was 6.6 (2.0-15.1) years. No patient had persistent, recurrent or new infection. There were four stem revisions for aseptic loosening. The mean Harris Hip Score was 81 points (26-99) at the final follow-up. Excellent cure rate and function seen in our study suggest that one-stage exchange is a safe procedure, even without local antibiotic treatment, provided that the patient has no sinus tract or severe soft tissue damage, no major bone grafting is required and the microorganism is susceptible to orally administered agents with high bioavailability.

  3. THE APPROACH OF THE KINETIC PROGRAM FOR HIPS WITH APPLIED ENDO-PROSTHESIS IN THE “LACU-SARAT BRAILA” RECOVERY CENTER (2006 – 2009.

    Directory of Open Access Journals (Sweden)

    Viorica Lefter

    2010-08-01

    Full Text Available Objectives. The objective of the present study is to relieve the necessity and the efficiency of the kinetic recovery of theoperated hip, and to increase the orthopedist’s trust in the kinetic act as a medical act executed in a responsible and understanding fashion by the qualified staff. Arthroplasty refers to the replacement of a joint deteriorated by a certain pathological process (degenerative arthritis, infection, or tumor with an artificial one, named endoprosthesis, a joint which must remain perfectly functional. The material and the method. The participants were 76 (63% mail patients and 45 (37% female patients, 44 (37% of which with ages between 40 and 60 years, 54 (45% between 60 and 70, and 21 (18% exceeded 70 years of ageInclusion criteria for the study werethe display of the following symptoms: chronic pain, acute pain andmobility reduction. Thus, 52 (42% patients featured acute pain, 42 (33% chronic pain and 35 (27% mobility disorders accompanied by walk disorders, that is, tilting pelvis 67 (55% and limping 54 (45% (Fig. 3, (Fig. 4 with hip prostheses of different types and at various intervals from the intervention. Subjects were clinically, functionally, radiologically and MRI investigated, preoperatively, postoperatively, after 3 months and after 1 year. A recovery program featuring educational, hygienic, diet, medication and physical-kinetic aspects was applied daily for a 14 to 15-day period, followed by kinesiotherapy and massage 2 to 3 times a week, by reevaluation and by a complete treatment at 3 months and at 1 year, respectively. Monitoring was made by the VAS scale for pain, Womac Lequesne for the functional status and Tinetii for the walk. Results. All patients have been evaluated initially, after 10 days and at the completion of the treatment, after 3 months and after 1 year. The recovery of hip arthroplasty must be carried out in time and maintained for the entire life.Conclusions.. Hips with applied endo-prosthesis

  4. Ipsilateral Fracture Shaft Femur with Neglected Dislocation of Prosthesis: A Case Report

    Directory of Open Access Journals (Sweden)

    Mantu Jain

    2013-10-01

    Full Text Available Introduction: Neglected hip dislocation is rare in today’s world and after prosthesis replacement even rarer finding. However such patients may not report to surgeons until they develop secondary complications. Management of such patient’s is a challenge to the treating surgeon and need to be tailored suiting to patient’s demands, expectations and constraints of financial resources. We did not find a similar case in the electronic and print media and therefore report this case which was innovatively managed. Case Report: A 60 year farmer presented with fracture shaft femur and ipsilateral dislocation prosthesis of right hip. He had a hemiarthroplasty done for fracture neck of femur in the past but used to walk with a lurch since he started to ambulate after discharge. However he was satisfied despite “some problems” which had caused shortening of his limb. The patient was informed of the various treatment options and their possible complications. He expressed his inability to afford a Total Hip Arthroplasty (THA at any stage and consented for other options discussed with him. The patient was positioned supine and adductor tenotomy done. Next he was positioned laterally and the fracture was fixed with heavy duty broad dynamic compression plate and screws. The wound was temporarily closed. Now through the previous scar via posterior approach the hip was exposed. The prosthesis was found to be firmly fixed to the proximal femur. The acetabulum was cleared with fibrous tissue. All attempts the prosthesis to relocate the prosthesis failed after several attempts and it was best decided to leave alone. Post operatively period was uneventful. At follow up he refused for any further manoeuvre in future inform of heavy traction and attempts to reduce the same. At one year when he was walking unaided and his X-rays showed that fracture had well united his SF-36 score was PCS – 49.6 and MCS – 51.9. Conclusion: Ipsilateral shaft femur fracture

  5. Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection

    Science.gov (United States)

    Cazanave, Charles; Greenwood-Quaintance, Kerryl E.; Hanssen, Arlen D.; Karau, Melissa J.; Schmidt, Suzannah M.; Gomez Urena, Eric O.; Mandrekar, Jayawant N.; Osmon, Douglas R.; Lough, Lindsay E.; Pritt, Bobbi S.; Steckelberg, James M.

    2013-01-01

    We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee (n = 272) or hip (n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture (P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure. PMID:23658273

  6. Mechanical analysis of a ceramic head being part of a modular hip prosthesis

    International Nuclear Information System (INIS)

    Ravagli, Ermenegildo

    1998-04-01

    This report still pursues the aim of carrying out a systematic mechanical analysis of a ceramic head being part of a modular hip prosthesis, in order to characterize it exhaustively, i.e. to assess its performances and some of its main specifications. Here in particular the aim is to locate the stress of the head when it undergoes the load transferred by the stem, presuming that the stem-head mating is not perfect, but there is a conical error called of the 2. type, to which corresponds a stem summit angle smaller than the one in the head hole. This conical error changes considerably the head stress and therefore this study is considered decisive for a later correct assessment of its resistance to breaking. This study is performed in the frame of the STRIDE-CETMA Project, which is aimed at founding and developing a Centre for technologically advanced materials in Brindisi (Italy) Technology Park [it

  7. Psoas abscess masquerading as a prosthetic hip infection: A case report.

    Science.gov (United States)

    Atif, Muhammad; Malik, Azeem Tariq; Noordin, Shahryar

    2018-01-01

    Psoas abscess is an unusual condition and is defined as a collection of pus in the iliopsoas compartment. Due to the unique anatomy of psoas muscle it forms a conduit for spread of infection from upper part of body to hip joint in neglected cases. A 67year old lady presented with left groin pain for three weeks. She underwent an uncemented unipolar hemiarthoplasty eight years back. Currently, she developed fever and was unable to do any active left hip range of motion. Passive motion of the left hip was restricted to 30° flexion, no internal rotation, 5° external rotation, and 10° abduction. Lab workup showed raised serum infective markers and radiographs of pelvis were normal with no evidence of any radiolucency. Ultrasound guided aspiration of left hip joint showed E coli. Arthrotomy revealed clear fluid in hip joint but pus was drained at psoas insertion. Later on, culture reported presence of E. coli and biopsy confirmed psoas abscess. Postoperatively CT scan abdomen showed pyelonephritis. Antibiotics were given for three months. Twenty months later, she remains asymptomatic without evidence of infection with normal gait. Psoas abscess is a rare clinical entity that may mimic symptoms of a primary prosthetic hip infection. Treatment outcomes are directly related to early detection with adequate dissection of the psoas muscle up to sites of attachment and complete eradication of infection. This case highlights importance of thorough initial clinical examination, lab workup and radiological assessment to rule out rare causes of hip joint pain. Copyright © 2017. Published by Elsevier Ltd.

  8. One-year incidence of prosthetic joint infection in total hip arthroplasty

    DEFF Research Database (Denmark)

    Gundtoft, P H; Pedersen, A B; Schønheyder, H C

    2017-01-01

    OBJECTIVE: To examine the trend of Prosthetic Joint Infections (PJI) following primary total hip arthroplasty (THA) and the antimicrobial resistance of the bacteria causing these infections. MATERIALS AND METHODS: We identified a population-based cohort of patients in the Danish Hip Arthroplasty...

  9. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement

    International Nuclear Information System (INIS)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-01-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis

  10. Radiological evaluation of failed total hip replacement

    International Nuclear Information System (INIS)

    Raspa, V.; Aldrovandi, S.; Pompei, G.

    1988-01-01

    The retrospective study of 50 operated cases of cemented total hip replacement and a review of the literature enabled the authors to define the radiological features of the above-mentioned condition. These features include one or more of the following signs: calcar reabsorption, lacunar erosions, modified relatioships between the prosthesis components, sepsis and loosening, periarticular calcifications dislocation and fracture of prosthesis components. Careful evaluation of these radiological features is extremely important for both an early diagnosis of failed total hip replacement and the choice of an adequate surgical treatment

  11. A biodegradable gentamicin-hydroxyapatite-coating for infection prophylaxis in cementless hip prostheses

    Directory of Open Access Journals (Sweden)

    D Neut

    2015-01-01

    Full Text Available A degradable, poly (lactic-co-glycolic acid (PLGA, gentamicin-loaded prophylactic coating for hydroxyapatite (HA-coated cementless hip prostheses is developed with similar antibacterial efficacy as offered by gentamicin-loaded cements for fixing traditional, cemented prostheses in bone. We describe the development pathway, from in vitro investigation of antibiotic release and antibacterial properties of this PLGA-gentamicin-HA-coating in different in vitro models to an evaluation of its efficacy in preventing implant-related infection in rabbits. Bone in-growth in the absence and presence of the coating was investigated in a canine model. The PLGA-gentamicin-HA-coating showed high-burst release, with antibacterial efficacy in agar-assays completely disappearing after 4 days, minimising risk of inducing antibiotic resistance. Gentamicin-sensitive and gentamicin-resistant staphylococci were killed by the antibiotic-loaded coating, in a simulated prosthesis-related interfacial gap. PLGA-gentamicin-HA-coatings prevented growth of bioluminescent staphylococci around a miniature-stem mounted in bacterially contaminated agar, as observed using bio-optical imaging. PLGA-gentamicin-HA-coated pins inserted in bacterially contaminated medullary canals in rabbits caused a statistically significant reduction in infection rates compared to HA-coated pins without gentamicin. Bone ingrowth to PLGA-gentamicin-HA-coated pins, in condylar defects of Beagle dogs was not impaired by the presence of the degradable, gentamicin-loaded coating. In conclusion, the PLGA-gentamicin-HA-coating constitutes an effective strategy for infection prophylaxis in cementless prostheses.

  12. Hip arthroplasty for ochronosis

    International Nuclear Information System (INIS)

    Kerimoglu, S.; Onder, C.; Aynaci, O.; Malkoc, C. H.

    2005-01-01

    Alkaptonuria is a metabolic disorder in which homogentisic acid oxidase is absent. Therefore, homogentisic acid accumulates in cartilage and connective tissues. We can diagnose ochronotic arthropathy, a manifestation of long standing alkaptonuria, through careful radiological, physical, and laboratory examination. In this report, we describe 4 cases of ochronotic arthropathy to which we applied cementless total hip prosthesis due to severe hip involvement. (author)

  13. Determination of digitised radiograph magnification factors for pre-operative templating in hip prosthesis surgery

    Energy Technology Data Exchange (ETDEWEB)

    Descamps, Stephane [Hopital Gabriel Montpied, CHU de Clermont Ferrand, BP 69, Service de Chirurgie Orthopedique et Traumatologique, Clermont Ferrand Cedex 01 (France); Livesey, Christine; Learmonth, Ian Douglas [Southmead Hospital, Westbury-on-Trym, Bristol Implant Research Centre, Avon Orthopaedic Centre, Bristol (United Kingdom)

    2010-03-15

    With digital radiography development, information technology (IT) companies have developed specific software for templating procedures, requiring individual magnification assessments for each patient. The aim of this study was to determine the mean magnification factor of digital radiographs and to evaluate the possibility of using the mean magnification factor or clinical information in templating. We retrospectively evaluated 100 primary total hip arthroplasty digital radiographs using the femoral head prosthesis as a calliper to determinate the mean magnification factor. Working on the assumption that altitude of the hip during radiograph is decisive in modification of magnification factors, we also looked for a correlation between weight, body mass index (BMI), altitude and magnification factor. The magnification factor was 126% (121-130%). A relationship was found between magnification factor (Mf) and weight (Mf = 7.10{sup -4} x weight (kg) + 1.21), but not BMI. In 98% of cases, if the weight-correlated formula is used, the sizing is correct or the error is {+-} 1 mm. With the mean method the sizing is correct or within 1 mm in only 78.2% of cases. Levels of accuracy for the mean magnification factor and the weight-correlated formula are not as high as individual assessments using a calliper; however, they could be used in everyday practice where individual magnification factors have not been calculated. (orig.)

  14. Quantitating the effect of prosthesis design on femoral remodeling using high-resolution region-free densitometric analysis (DXA-RFA)

    DEFF Research Database (Denmark)

    Farzi, Mohsen; Morris, Richard M; Penny, Jeannette

    2017-01-01

    Dual energy X-ray absorptiometry (DXA) is the reference standard method used to study bone mineral density (BMD) after total hip arthroplasty (THA). However, the subtle, spatially complex changes in bone mass due to strain-adaptive bone remodeling relevant to different prosthesis designs are not ......Dual energy X-ray absorptiometry (DXA) is the reference standard method used to study bone mineral density (BMD) after total hip arthroplasty (THA). However, the subtle, spatially complex changes in bone mass due to strain-adaptive bone remodeling relevant to different prosthesis designs...... using scans acquired during two previous randomized clinical trials (2004 to 2009); one comparing three cemented prosthesis design geometries, and the other comparing a hip resurfacing versus a conventional cementless prosthesis. DXA RFA resolved subtle differences in magnitude and area of bone...... remodeling between prosthesis designs not previously identified in conventional DXA analyses. A mean bone loss of 10.3%, 12.1%, and 11.1% occurred for the three cemented prostheses within a bone area fraction of 14.8%, 14.4%, and 6.2%, mostly within the lesser trochanter (p 

  15. Managing infection in the revision total hip replacement patient.

    Science.gov (United States)

    Halley, D K

    1993-01-01

    Deep infection is one of the most devastating complications in total hip replacement. This dreaded complication is presented in considerable detail with special emphasis on prevention, diagnosis, and various methods of surgical and antibiotic treatment. Basic fundamentals of antibiotic therapy are reviewed. In addition, guidelines are given for the indications of surgical intervention, the type and staging of operative procedures, with detailed techniques of the various operative procedures used to treat the infected total hip implant patient.

  16. The Use of a Supra-Acetabular Antibiotic-Loaded Cement Shelf to Improve Hip Stability in First-Stage Infected Total Hip Arthroplasty.

    Science.gov (United States)

    Drexler, Michael; Kuzyk, Paul R T; Koo, Kevin; Gross, Allan E; Kosashvili, Yona; Reischl, Nickola; Rutenberg, Tal Frenkel; Safir, Oleg

    2016-11-01

    Antibiotic-loaded cement spacers in first-stage revision total hip arthroplasty (THA) for managing infection are associated with high dislocation and fracture rates. The aim of this study was to report the use of an antibiotic-loaded cemented supra-acetabular roof augmentation to reinforce hip stability after cement spacer insertion for first-stage total hip revision in the treatment of infected THA. We retrospectively reviewed a consecutive series of 50 THAs involving 47 patients with an infected hip requiring staged revisions of THA. We documented dislocation, reinfection, and time for revision and outcome. There were no cases of hip dislocation, cement fractures, or any other technical complications associated with the use of the roof augmentation lip. Thirteen cases (26%) had a cemented spacer for longer than 120 days. Seven (14%) cases had recurrent infection after staged revision THA. The antibiotic-loaded cemented supra-acetabular roof augment improved femoral head spacer coverage for patients requiring a staged revision THA for infection. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Radiological and scintigraphic evaluation of hip prostheses

    International Nuclear Information System (INIS)

    Bessler, W.; Schaub, W.

    1979-01-01

    The radiological findings following the introduction of hip prostheses are often equivocal. Additional bone scintigrams often provide important information for the evaluation of the prostheses. 1. An unstable hip prosthesis is characterised by abnormal uptake in bone, due to static and mechanical stress. 2. A positive scintigram does not necessarily indicate instability of the prosthesis. Increased uptake may also be due to inflammatory bone changes, healing, bone replacement, abnormal local stresses or soft tissue calcification. 3. In evaluating the scintigram one must take account not only of the intensity of isotope uptake, but also its distribution and exact localisation. 4. It is essential to compare the scintigram with the radiograph. Radiological features of possible instability become diagnostic if they correspond with appropriate increased radioactivity. If the latter is absent, the of instability remains doubtful. 5. In some cases early loosening of the stem of the prosthesis can be diagnosed while the radiograph is still negative. Increased radioactivity in the acetabulum is frequently seen in the presence of a stable acetabular prosthesis and must be interpreted with caution as a sign of loosening of the prosthesis. (orig.) [de

  18. Evaluation of Gait Performance of a Hemipelvectomy Amputation Walking with a Canadian Prosthesis

    Directory of Open Access Journals (Sweden)

    M. T. Karimi

    2014-01-01

    Full Text Available Background. Hemipelvectomy amputation is a surgical procedure in which lower limb and a portion of pelvic are removed. There are a few studies in the literature regarding the performance of subjects with hip disarticulation during walking. However, there is no study on gait analysis of hemipelvectomy subject. Therefore, the aim of this paper was to evaluate the gait and stability of subject with hemipelvectomy amputation. Case Description and Methods. A subject with hemipelvectomy amputation at right side was involved in this study. He used a Canadian prosthesis with single axis ankle joint, 3R21 knee joint, and 7E7 hip joint for more than 10 years. The kinetic and kinematic parameters were collected by a motion analysis system and a Kistler force platform. Findings and Outcomes. There was a significant difference between knee, hip, and ankle range of motions and their moments in the sound and prosthesis sides. In the other side, the stability of the subject in the anteroposterior direction seems to be better than that in the mediolateral direction. Conclusions. There was a significant asymmetry between the kinetic and kinematic performance of the sound and prosthesis sides, which may be due to lack of muscular power and alignment of prosthesis components.

  19. STUDY OF FUNCTIONAL RESULTS OF CEMENTED TOTAL HIP REPLACEMENT BY MOORE’S APPROACH

    Directory of Open Access Journals (Sweden)

    Arunim

    2016-02-01

    Full Text Available INTRODUCTION The total hip replacement (THR has probably become the surgical procedure of choice for vide variety of hip joint disabling diseases. The prosthesis used for THR is often grouped into cemented, cement-less and hybrid ones. There has been increasing trends in use of cement-less components citing more number of complications namely loosening, increased infection rate etc. however with additional cost factors as well. We conducted this study to ascertain whether in a developing country like ours should we really switch over to un-cemented hip replacements dreading such complications or can we still use cemented prosthesis with equally good if not better results. METHODS A study of functional results of cemented total hip replacement was done in patients with varied age groups ranging from 40 years to 75 years with the average age being 54.8 years. 20 patients with 21 diseased hips were treated with cemented total hip replacement by Moore’s posterior approach at NSCB Subharti medical college, Meerut, UP from December 2010 to December 2013 and reviewed thereafter with an average follow-up period of 4.2 years. Average surgical time required was one and half hour. Patients were asked to come for follow up on 1st month, 3rd month and 6th month and then every 6 months and were assessed as per modified Harris Hip Score. RESULTS All the patients were evaluated according to the Modified Harris Hip Scoring system. The results showed 14(67% hips with excellent results, 4(19% with good results, and 3(14% hips with fair results. No poor outcome was noted in this study. 2 cases of dislocation (10% were noted one on the 5th post-operative day and the other occurred after the patient was discharged from the institution. CONCLUSIONS The management of diseased and destroyed hips with chronic pain with cemented total hip replacement is effective and gives stable, mobile and painless hip joint to the patient. Functional results are excellent and

  20. In situ replacement of infected vascular prosthesis with fresh arterial homograft: Early and long-term results in 18 patients

    Directory of Open Access Journals (Sweden)

    Pejkić Siniša

    2013-01-01

    Full Text Available Introduction. Graft infection is rightly considered one of the severest complications of vascular reconstruction. Treatment is non­standardized and associated with high mortality and morbidity rates. The choice of therapeutic modality depends upon variety of factors. One increasingly used option is in situ replacement of the infected prosthesis with the arterial allograft. Objective. The aim of this prospective nonrandomized study was to evaluate the effectiveness and durability of fresh arterial allograft as in situ substitute for the infected vascular prosthesis. Methods. During period of 2002-2005, 18 patients with the synthetic vascular graft infection underwent partial or complete prosthesis removal and secondary in situ reconstruction using the fresh arterial allograft, preserved under hypothermic conditions in buffered saline solution with an addition of antibiotics. Results. In 14 male and 4 female patients, meanaged 62 years, 8 aortic and 10 peripheral arterial infected prostheses were partially or completely replaced with the allograft. Operative mortality was 27.8% and amputation rate was 22.2%. Systemic sepsis at initial presentation and highly virulent nature of causative microorganisms were identified as significant negative prognostic factors (χ² test, p<0.05. During the long­term follow­up (mean 47 months, allograft aneurysm developed in three patients, requiring allograft explantation, followed in two cases by tertiary prosthetic reconstruction. Conclusion. Substitution of the infected prosthesis with the arterial allograft could be successful if used selectively - for less virulent and localized infections of extracavitary grafts. Close follow­up is mandatory for timely diagnosis of late homograft lesions and its eventual replacement with more durable prosthetic material.

  1. Radiological evaluation of painful total hip replacement

    International Nuclear Information System (INIS)

    Tehranzadeh, J.; Schneider, R.; Freiberger, R.H.

    1981-01-01

    Ninety-four cases of clinically failed, cemented, total hip prostheses requiring surgery were reviewed to determine the accuracy of preoperative plain radiography, culture of aspirated fluid, arthrography, and bone scanning. When radiopaque cement had been used to embed the prosthesis, plain radiography was highly accurate in detecting a loose femoral component, less so in detecting a loose acetabular component. Culture of aspirated fluid was accurate in diagnosing infection. A positive arthrogram identified loosening with good accuracy; however, a negative arthrogram did not reliably exclude loosening. 99 mTc bone scans frequently differentiated loosening from loosening with infection. The suggested sequence of diagnostic tests is plain radiography followed by bone scanning. If the bone scan shows diffuse augmented uptake, culture of aspirated fluid followed by arthrography is indicated

  2. Use of Common Inflammatory Markers in the Long-Term Screening of Total Hip Arthroprosthesis Infections: Our Experience

    Directory of Open Access Journals (Sweden)

    Gabriele Falzarano

    2017-01-01

    Full Text Available Orthopedic implants have become essential components of modern medicine. The risk of infection of total hip arthroplasty (THA is 1.5%−2%. Are the C-reactive protein (CRP, the erythrocyte sedimentation rate (ESR, and procalcitonin (PCT good markers for THA infection screenings? From February 2009 to December 2012 at our Department of Orthopedics and Traumatology, 1248 patients were treated with THA. No prosthesis was cemented. All patients received antibiotic prophylaxis. All patients were discharged approximately 7.4 days after surgery with this clinical and radiographic follow-up program at 15 days and 1, 3, 6, 12, 24, and 36 months after surgery. Blood samples to determine ESR, CRP, and PCT values were taken at 1 hour before surgery and 15 days and 1, 3, 6, 12, 24, and 36 months after surgery. During follow-ups there were 22 cases of THA infections; according the Widmer classification, infections are hematogenous ones in 16 cases, late chronic ones in 5 cases, and early postoperative ones in 1 case. In all cases the three markers were considered positive; in 6 cases there were no radiological signs of septic loosening. ESR, CRP, and PCT proved to have a greater diagnostic accuracy than X-rays in predicting late chronic and early postoperative infections. These markers are valuable support for the surgeon in monitoring the prosthetic implant lifespan.

  3. Total Hip Arthroplasty Loosening Due to Mycobacterium Tuberculosis: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Anis Tebourbi

    2017-04-01

    Full Text Available Context: Prosthetic joint infection due to Mycobacterium tuberculosis with no previous history of pulmonary or extra pulmonary tuberculosis is an extremely rare complication. Aims To report the case of a patient with tuberculous mycobacterial prosthetic hip infection, 14 years after surgery for post traumatic osteoarthritis, with no previous history of tuberculosis. Methods A 46-year-old male presented an acetabular loosening of a cemented total hip arthroplasty with subnormal biologic parameters. A one stage revision surgery was planned. Intraoperative findings suggested mycobacterial tuberculous infection with presence of periacetabular yellowish rice-shaped granules. Results A one-stage prosthesis exchange was performed; Culture on Löwenstein-Jensen medium grew MTB days after inoculation and histological examination confirmed tuberculous infection. Patient was treated by antituberculous agents for 12 months with optimal clinical and biological response and no prosthetic loosening signs at eighteen months follow up. Conclusions Total hip arthroplasty loosening due to mycobacterium tuberculosis is a rare entity, which should be evoked even when no inflammatory signs are shown. Discovery of yellowish rice-shaped granules is an indicator to investigate for tuberculosis. Management of prosthetic joint infection due to M.tuberculosis must involve both medical and surgical approach.

  4. Specific Infectious Organisms Associated With Poor Outcomes in Treatment for Hip Periprosthetic Infection.

    Science.gov (United States)

    Cunningham, Daniel J; Kavolus, Joseph J; Bolognesi, Michael P; Wellman, Samuel S; Seyler, Thorsten M

    2017-06-01

    Periprosthetic hip infection treatment remains a significant challenge for orthopedics. Some studies have suggested that methicillin resistance and gram-negative organism type are associated with increased treatment failure. The aim of this research is to determine if specific organisms were associated with poor outcomes in treatment for hip periprosthetic infection. Records were reviewed of all patients between 2005 and 2015 who underwent treatment for infected partial or total hip arthroplasty. Characteristics of each patient's treatment course were determined including baseline characteristics, infecting organism(s), infection status at final follow-up, surgeries for infection, and time in hospital. Baseline characteristics and organisms that were associated with clinical outcomes in univariate analysis were incorporated into multivariable outcomes models. When compared with patients infected with other organism(s), patients infected with the following organisms had significantly decreased infection-free rates: Pseudomonas, methicillin-resistant Staphylococcus aureus (MRSA), and Proteus. Infection with certain organisms was associated with 1.13-2.58 additional surgeries: methicillin-sensitive S aureus, coagulase-negative Staphylococcus, MRSA, Pseudomonas, Peptostreptococcus, Klebsiella, Candida, diphtheroids, Propionibacterium acnes, and Proteus species. Specific organisms were associated with 8.56-24.54 additional days in hospital for infection: methicillin-sensitive S aureus, coagulase-negative Staphylococcus, Proteus, MRSA, Enterococcus, Pseudomonas, Klebsiella, beta-hemolytic Streptococcus, and diphtheroids. Higher comorbidity score was also associated with greater length of hospitalization. MRSA, Pseudomonas, and Proteus were associated with all 3 outcomes of lower infection-free rate, more surgery, and more time in hospital in treatment for hip periprosthetic infection. Organism-specific outcome information may help individualize patient

  5. The effect of endoskeleton on antibiotic impregnated cement spacer for treating deep hip infection

    Directory of Open Access Journals (Sweden)

    Hsu Wei-Hsiu

    2011-01-01

    Full Text Available Abstract Backgrounds A two-stage revision arthroplasty was suggested optimal treatment for deep infections in hip joint. The effect of endoskeleton of cement spacers on the interim function and infection control remains unclear. Methods From Jan. 2004 to Dec. 2007, we collected a prospective cohort of consecutive 34 patients who treated with two-stage revision total hip arthroplasty for deep infection of hip joint. In group 1, fifteen patients were treated by a novel design augmented with hip compression screw while nineteen patients were treated by traditional design in group 2. Results No fracture of cement spacer occurred in group 1 while 6 cases developed spacer failure in group 2. (p Conclusions Patients being treated for deep infection of hip joint using cement spacer augmented with stronger endoskeleton have lower pain levels and better joint function between stages.

  6. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    Science.gov (United States)

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Prosthetic hip joint infection due to Campylobacter fetus.

    OpenAIRE

    Bates, C J; Clarke, T C; Spencer, R C

    1994-01-01

    A case of postoperative prosthetic hip joint infection due to Campylobacter fetus subsp. fetus is described. Difficulties in isolation and antimicrobial susceptibility testing of this organism are discussed.

  8. THR Simulator – the software for generating radiographs of THR prosthesis

    Directory of Open Access Journals (Sweden)

    Hou Sheng-Mou

    2009-01-01

    Full Text Available Abstract Background Measuring the orientation of acetabular cup after total hip arthroplasty is important for prognosis. The verification of these measurement methods will be easier and more feasible if we can synthesize prosthesis radiographs in each simulated condition. One reported method used an expensive mechanical device with an indeterminable precision. We thus develop a program, THR Simulator, to directly synthesize digital radiographs of prostheses for further analysis. Under Windows platform and using Borland C++ Builder programming tool, we developed the THR Simulator. We first built a mathematical model of acetabulum and femoral head. The data of the real dimension of prosthesis was adopted to generate the radiograph of hip prosthesis. Then with the ray tracing algorithm, we calculated the thickness each X-ray beam passed, and then transformed to grey scale by mapping function which was derived by fitting the exponential function from the phantom image. Finally we could generate a simulated radiograph for further analysis. Results Using THR Simulator, the users can incorporate many parameters together for radiograph synthesis. These parameters include thickness, film size, tube distance, film distance, anteversion, abduction, upper wear, medial wear, and posterior wear. These parameters are adequate for any radiographic measurement research. This THR Simulator has been used in two studies, and the errors are within 2° for anteversion and 0.2 mm for wearing measurement. Conclusion We design a program, THR Simulator that can synthesize prosthesis radiographs. Such a program can be applied in future studies for further analysis and validation of measurement of various parameters of pelvis after total hip arthroplasty.

  9. COMPARISON OF CULTURE OF SYNOVIAL FLUID, PERIPROSTHETIC TISSUE AND PROSTHESIS SONICATE FOR THE DIAGNOSIS OF KNEE PROSTHESIS INFECTION

    Directory of Open Access Journals (Sweden)

    Andrej Trampuž

    2003-03-01

    Full Text Available Background. Synovial fluid and periprosthetic tissue specimens are the standard specimens cultured for the diagnosis of prosthetic joint infection (PJI. We hypothesize that ultrasonication of the explanted prosthesis may improve diagnosis of PJI by dislodging biofilm bacteria from the prosthesis surface and improve the sensitivity and specificity of diagnosis of PJI.Methods. Included were patients undergoing knee prosthesis exchange for septic or biomechanical failure and have not received antimicrobial therapy in the last 2 weeks prior specimen collection. Cultures of synovial fluid and periprosthetic tissue specimens were performed per the usual clinical practice. Additionally, explanted joint components were sonicated for 5 minutes at frequency 40 kHz in sterile Ringer’s solution; aliquots of 0.5 ml sonicate were plated onto five aerobic and five anaerobic blood agar plates, and incubated at 37 °C and examined for the next seven days. The number and identity of each colony morphology was recorded.Results. 35 patients undergoing knee replacement have been studied (24 for aseptic biomechanical failure and 11 for suspected PJI. In patients with PJI, coagulase-negative staphylococci (7 cases, Corynebacterium spp. (2 cases, Staphylococcus aureus (1 case, and viridans group streptococcus (1 case were recovered. Culture sensitivity and specificity were for synovial fluid 88% and 100%, for periprosthetic tissue 83% and 81%, and for explant sonicate 91% and 100%, respectively. In sonicate cultures higher numbers of microorganisms than in periprosthetic tissue cultures were consistently detected.Conclusions. Using synovial fluid, periprosthetic tissue, and explant sonicate cultures, 12%, 17% and 9% of PJI were missed, respectively. Explant sonicate cultures were the most sensitive with respect to the diagnosis of PJI, indicating that explant ultrasonication may improve bacterial recovery. In sonicate cultures, infecting organisms were detected in

  10. Periprosthetic fungal infection of a hip caused by Trichosporon inkin

    Directory of Open Access Journals (Sweden)

    Federico José Burgo, MD

    2018-03-01

    Full Text Available An immunocompromised patient with a history of multiple hip implant revisions extended courses of empiric antibiotic treatment, and a retained metallic rod in the femoral medullary canal was transferred for diagnostic studies and treatment. A high suspicion of fungal infection and utilization of extended and specific fungal cultures were the diagnostic keys for infection with Trichosporon inkin. The treatment consisted in a debridement surgery with the use of a functional spacer with cement supplemented with voriconazole and vancomycin plus a 6-month systemic treatment with voriconazole. After 2 years of follow-up, the patient is free of symptoms. Keywords: Hip arthroplasty, Periprosthetic fungal infection, Trichosporon inkin

  11. Radiography, radionuclide imaging, and asthrography in the evaluation of total hip and knee replacement. [/sup 99m/Tc-phosphate

    Energy Technology Data Exchange (ETDEWEB)

    Gelman, M.I.; Coleman, R.E.; Stevens, P.M.; Davey, B.W.

    1978-09-01

    Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis.

  12. Total hip arthroplasty in Jesenice General hospital 1985–2006 – what has been done and look forward

    Directory of Open Access Journals (Sweden)

    Tomaž Silvester

    2007-11-01

    Full Text Available Background: Total arthroplasty is one of the most interesting and fast developing fields in orthopaedic surgery. Practically every joint in the human body is involved, total hip arthroplasties (THA being most frequent and with the longest history. Information on long-term results and survival of different types of prosthesis is invaluable for both patients and surgeons.Patients and methods: Between 1985 and 2006 there were 1563 THAs performed in Jesenice General Hospital. Average age at the time of operation was 67 years, almost two thirds of patients were women. The reason for operation was in 72 % idiopathic arthrosis and in 14 % sequaele of dysplasia.Results: There were 1370 primary procedures and 193 revisions (12.6 %. Aseptic loosening of the implant was the most frequent reason for revision (74 % and infection was observed in 1.5 %. In the first ten years of this research hybrid type of prosthesis was most frequently used, but nowadays, non-cemented prosthesis is used in majority of cases.Conclusions: Total hip arthroplasty is well established procedure at the Jesenice General Hospital. It considerably improves quality of life of the patient, for both, short- and long term, results are very good. New minimal invasive surgical techniques make postoperative rehabilitation faster and easier. The Register of prosthesis enables us to regularly analyze the results and provides treatment outcome information concerning the choice of prosthesis and the optimal surgical technique. Jesenice General Hospital is well recognized as one of the centers for arthroplasties in our country.

  13. Numerical analysis of the biomechanical complications accompanying the total hip replacement with NANOS-Prosthetic: bone remodelling and prosthesis migration

    Directory of Open Access Journals (Sweden)

    Almohallami A.

    2015-09-01

    Full Text Available Aseptic loosening of the prosthesis is still a problem in artificial joint implants. The ýloosening can be caused by the resorption of the bone surrounding ýthe prosthesis according to stress shielding. A numerical model was developed and validated by means of DEXA-studies in order to ýanalyse the bone remodelling process in the periprosthetic bone. A total loss of about 3.7% of the bone density in the periprosthetic Femur with NANOS is computed. The bone remodelling calculation was validated by means of a DEXA-study with a 3-years-follow-up. The model was further developed in order to be able to calculate and consider the migration of the implants. This method was applied on the ýNANOS-implant with a computed total migration of about 0.43 mm. These calculations showed good results in comparison with a 2-year-follow-up clinical study, whereby a RSA-method was used to determine the stem migration in the bone. In order to ýstudy the mutual influence between the implant migration and the hip contact forces ý, a software is developed by our scientific group to couple a multi body simulation (MBS of human lower limps with the FEA of the periprosthetic Femur.

  14. A case study of radiotherapy planning for a bilateral metal hip prosthesis prostate cancer patient

    International Nuclear Information System (INIS)

    Su, Andy; Reft, Chester; Rash, Carla; Price, Jennifer; Jani, Ashesh B.

    2005-01-01

    The purpose of this report is to communicate the observed advantage of intensity-modulated radiotherapy (IMRT) in a patient with bilateral metallic hip prostheses. In this patient with early-stage low-risk disease, a dose of 74 Gy was planned in two phases-an initial 50 Gy to the prostate and seminal vesicles and an additional 24 Gy to the prostate alone. Each coplanar beam avoided the prosthesis in the beam's eye view. Using the same target expansions for each phase, IMRT and 3D-conformal radiotherapy (CRT) plans were compared for target coverage and inhomogeneity as well as dose to the bladder and rectum. The results of the analysis demonstrated that IMRT provided superior target coverage with reduced dose to normal tissues for both individual phases of the treatment plan as well as for the composite treatment plan. The dose to the rectum was significantly reduced with the IMRT technique, with a composite V80 of 35% for the IMRT plan versus 70% for 3D-CRT plan. Similarly, the dose to the bladder was significantly reduced with a V80 of 9% versus 20%. Overall, various dosimetric parameters revealed the corresponding 3D-CRT plan would not have been acceptable. The results indicate significant success with IMRT in a clinical scenario where there were no curative alternatives for local treatment other than external beam radiotherapy. Therefore, definitive external beam radiation of prostate cancer patients with bilateral prosthesis is made feasible with IMRT. The work described herein may also have applicability to other groups of patients, such as those with gynecological or other pelvic malignancies

  15. Non-infected penile prosthesis cultures during revision surgery; comparison between antibiotic coated and non - coated devices

    Directory of Open Access Journals (Sweden)

    Seyfettin Ciftci

    Full Text Available ABSTRACT Introduction: Aim of this study is to investigate bacterial growth on non-infected devices and compare antibiotic-coated and non-coated implants. Materials and methods: The charts of 71 patients who underwent revision surgeries for penile prosthesis between 1995 and 2013 were reviewed. Of those, 31 devices were antibiotic-coated prostheses, while 40 of the implants were non-coated. Swab cultures were routinely obtained from corporal, pump or reservoir site during the operation. If a bacterial biofilm was determined on the prosthesis, it was also cultured. Results: A total of 5 different organisms were cultured from 18 patients. Of them, 4 devices were antibiotic-coated and the other 14 were non-coated devices. Staphylococcus epidermidis was the most common organism, while Staphylococcus hominis, beta hemolitic streptococcus, Escherichia coli and Proteus mirabilis were also cultured. All patients who had positive cultures were treated with appropriate antibiotics for four weeks postoperatively. Median follow-up time was 41 months, ranging between 8 and 82 months. One prosthesis (non-coated became clinically infected in the follow-up period with a totally different organism. Culture positivity rates of antibiotic-coated and non-coated devices were 13% and 35% respectively and the result was significant (p=0.00254. Conclusions: Positive bacterial cultures are present on non-infected penile prostheses at revision surgeries in some of the patients. Antibiotic coated prostheses have much less positive cultures than non-coated devices.

  16. Analysis of 18 F-FDG uptake patterns in PET for diagnosis of septic and aseptic loosening after total hip arthroplasty

    International Nuclear Information System (INIS)

    Cremerius, U.; Niethard, F.U.; Mumme, T.; Reinartz, P.; Wirtz, D.; Buell, U.

    2003-01-01

    Aim: Identification of typical patterns for fluorodeoxyglucose (FDG) uptake in positron emission tomography (PET) to detect aseptic loosening of hip prosthesis (acetabular and/or femoral component) and prosthetic infection. Methods: 18 patients with painful hip prosthesis underwent PET using a dedicated full ring scanner after application of 200-300 MBq FDG. The interface between bone and surrounding soft tissue or bone as displayed on coronal slices was divided into 12 segments in accordance with the classifications of Delee and Gruen. FDG uptake in each of the segments was scored (0-3) by two independent observers. Intraoperative findings were regarded as the gold standard. Results: After surgical revision 14 acetabular components and 9 femoral components were found to be loose and prosthetic infection was present in 7 prostheses. Loosening of the acetabular component was correlated to enhanced uptake in the middle of the acetabular interface, while loosening of the femoral component was correlated to enhanced uptake in the proximal and middle segment of the lateral femoral interface and the proximal segment of the medial femoral interface. A similar pattern was found in prosthetic infection with high uptake along the middle portion of the lateral femoral interface. In 6 of 7 infected prostheses loosening of the acetabular and of the femoral component was present. Taking the typical uptake patterns as criteria for loosening and grade 3 uptake as an additional criterion for septic loosening the accuracy of PET imaging in the detection of loosening of the acetabular or the femoral component and of prosthetic infection was 72, 78 and 89%, respectively. Conclusion: This pilot study presents FDG-PET as a promising diagnostic tool for patients with painful hip prostheses. Its clinical value should be evaluated in a larger patient population. (orig.) [de

  17. Pinning down loosened prostheses : imaging and planning of percutaneous hip refixation

    NARCIS (Netherlands)

    Malan, Daniel Francois

    2015-01-01

    This thesis examines how computer software can be used to analyse medical images of an aseptically loosening hip prosthesis, and subsequently to plan and guide a minimally invasive cement injection procedure to stabilize the prosthesis. We addressed the detection and measurement of periprosthetic

  18. Comparison of radiographic and radionuclide hip arthrography in determination of femoral component loosening of hip arthroplasties

    International Nuclear Information System (INIS)

    Capello, W.N.; Uri, B.G.; Wellman, H.N.; Robb, J.A.; Stiver, P.L.

    1985-01-01

    Radiographic examination of a patient experiencing pain following total hip arthroplasty is an important step in the systematic approach to evaluating component loosening, even though the information yielded is often equivocal and nondiagnostic in assessing component loosening. The radiographic criteria for loosening are especially difficult to assess following revision surgery, for radiolucent lines frequently exist at the bone-cement interface immediately following implantation. The advent of noncemented hip prostheses poses another problem: the routinely noted disruption of bone-cement of prosthesis-cement interfaces is not present with uncemented prostheses. As the criteria for loosening of the noncemented prostheses are still evolving, plain radiographic examination is frequently nondiagnostic. Femoral component loosening is difficult to detect with standard contrast arthrography because the bone, metal, surrounding radiopaque cement and contrast agents have similar or identical radiographic appearances. In contrast arthrography, if the prosthesis is loose the injected agent opacifies the radiolucent zone encircling the prosthesis or cement mangle. Because of the similarity in the appearances of these agents and the surrounding structures on x-ray films, interpretation is difficult. The inclusion of subtraction techniques in routine contrast arthrography has improved its accuracy; however, these techniques require special equipment and demand precise patient positioning. The purpose of this study is to introduce a new form of hip arthrography using a radionuclide agent in place of the contrast agent. A comparison of the results using these two techniques is presented

  19. Determinación del desgaste del componente acetabular en prótesis totales de cadera. // Wear determination of acetabular component in total hip prosthesis.

    Directory of Open Access Journals (Sweden)

    G. García del Pino

    2002-01-01

    Full Text Available En este trabajo se realiza un estudio a través del Método de los Elementos Finitos “MEF” sobre el desgaste del componenteacetabular durante el ciclo de marcha y considerando algunos casos extremos de cargas como subir y bajar escaleras,levantarse de una silla, etc. Utilizando el MEF fueron modelados independientemente los componentes acetabular yfemoral de la prótesis total de cadera y puestos en contacto posteriormente. Fueron estudiadas varias posiciones delacetábulo así como diferentes casos de carga simulando pacientes con diferente peso corporal y actividades físicas. Paraevaluar los resultados se crearon rutinas en lenguaje C que organizaron los mismos para un tratamiento estadísticoposterior.Palabras claves: biomecánica, ortopedia, elementos finitos, modelación, desgaste, prótesis de cadera.___________________________________________________________________________Abstract.A wear study of acetabular component during the marching cycle, considering some extreme loads cases as: ascend anddescend stairways, get up from a seat, etc , by means of Finite Elements Method ( FEM , is carried out. The acetabular andfemoral component of the total hip prosthesis were independently modeled and placed in contact lastly. Several acetabulpositions were studied as well as different load cases, simulating patients with different body weight and different physicalactivities. To evaluate the results routines in C language were created in order to organized the same ones for a laterstatistical treatment.Key words. biomechanics, ortophedy, finite elements, modelation, wear, hip bone prosthesis.

  20. Irrigation and Debridement with Component Retention for Acute Infection After Hip Arthroplasty: Improved Results with Contemporary Management.

    Science.gov (United States)

    Bryan, Andrew J; Abdel, Matthew P; Sanders, Thomas L; Fitzgerald, Steven F; Hanssen, Arlen D; Berry, Daniel J

    2017-12-06

    There are conflicting data on the results of irrigation and debridement with component retention in patients with acute periprosthetic hip infections. The goals of this study were to examine contemporary results of irrigation and debridement with component retention for acute infection after primary hip arthroplasty and to identify host, organism, antibiotic, or implant factors that predict success or failure. Ninety hips (57 total hip arthroplasties and 33 hemiarthroplasties) were diagnosed with acute periprosthetic hip infection (using strict criteria) and were treated with irrigation and debridement and component retention between 2000 and 2012. The mean follow-up was 6 years. Patients were stratified on the basis of McPherson criteria. Hips were managed with irrigation and debridement and retention of well-fixed implants with modular head and liner exchange (70%) or irrigation and debridement alone (30%). Seventy-seven percent of patients were treated with chronic antibiotic suppression. Failure was defined as failure to eradicate infection, characterized by a wound fistula, drainage, intolerable pain, or infection recurrence caused by the same organism strain; subsequent removal of any component for infection; unplanned second wound debridement for ongoing deep infection; and/or occurrence of periprosthetic joint infection-related mortality. Treatment failure occurred in 17% (15 of 90 hips), with component removal secondary to recurrent infection in 10% (9 of 90 hips). Treatment failure occurred in 15% (10 of 66 hips) after early postoperative infection and 21% (5 of 24 hips) after acute hematogenous infection (p = 0.7). Patients with McPherson host grade A had a treatment failure rate of 8%, compared with 16% (p = 0.04) in host grade B and 44% in host grade C (p = 0.006). Most treatment failures (12 of 15 failures) occurred within the initial 6 weeks of treatment; failures subsequent to 6 weeks occurred in 3% of those treated with chronic antibiotic

  1. Immunoscintigraphy with antigranulocyte monoclonal antibodies for the diagnosis of septic loosening of hip prostheses

    International Nuclear Information System (INIS)

    Boubaker, A.; Bischof Delaloye, A.; Blanc, C.H.; Dutoit, M.; Leyvraz, P.F.; Delaloye, B.

    1995-01-01

    To determine the value of immunoscintigraphy (IS) with antigranulocyte monoclonal antibodies (Mab) in the diagnosis of subacute or chronic infection of hip prostheses, we prospectively studied 57 patients (23 women and 34 men; age 29-92 years, mean 72.7 years) sent to our institution in the past 6 years for clinical suspicion of septic loosening of a hip prosthesis. Nineteen patients had bilateral prostheses and one of them was studied twice. A total of 78 prostheses were examined. All patients had three-phase bone scans followed by IS with technetium-99m antigranulocyte Mab BW 250/183. Intervals between bone scans and IS varied from 2 days to 4 weeks. Final diagnosis was assessed by culture in 48 cases (articular puncture or intraoperative sampling) and by clinical follow-up of at least 8 months in 30 cases. Twelve prostheses were considered septic and 66 non-septic. The overall sensitivity and specificity were 92% and 64% respectively for bone scans, 67% and 75% for IS and 67% and 84% for both modalities together. In three cases, IS was doubtful and the final clinical diagnosis was negative for infection. False-positive results were observed in the presence of massive loosening of the prosthesis or in association with metaplastic peri-articular bone formation. In three of the four false-negative results, infection was proven only after enrichment of the culture, and the bacterium was Staphylococcus epidermidis. In 12/33 (36%) positive bone scans IS allowed the diagnosis of infection to be excluded. Overall accuracy of both modalities together was 81% and the negative predictive value was 93%, which compares favourably with the results reported for other non-invasive methods. (orig.)

  2. Comparison of different hip prosthesis shapes considering micro-level bone remodeling and stress-shielding criteria using three-dimensional design space topology optimization.

    Science.gov (United States)

    Boyle, Christopher; Kim, Il Yong

    2011-06-03

    Since the late 1980s, computational analysis of total hip arthroplasty (THA) prosthesis components has been completed using macro-level bone remodeling algorithms. The utilization of macro-sized elements requires apparent bone densities to predict cancellous bone strength, thereby, preventing visualization and analysis of realistic trabecular architecture. In this study, we utilized a recently developed structural optimization algorithm, design space optimization (DSO), to perform a micro-level three-dimensional finite element bone remodeling simulation on the human proximal femur pre- and post-THA. The computational simulation facilitated direct performance comparison between two commercially available prosthetic implant stems from Zimmer Inc.: the Alloclassic and the Mayo conservative. The novel micro-level approach allowed the unique ability to visualize the trabecular bone adaption post-operation and to quantify the changes in bone mineral content by region. Stress-shielding and strain energy distribution were also quantified for the immediate post-operation and the stably fixated, post-remodeling conditions. Stress-shielding was highest in the proximal region and remained unchanged post-remodeling; conversely, the mid and distal portions show large increases in stress, suggesting a distal shift in the loadpath. The Mayo design conserves bone mass, while simultaneously reducing the incidence of stress-shielding compared to the Alloclassic, revealing a key benefit of the distinctive geometry. Several important factors for stable fixation, determined in clinical evaluations from the literature, were evident in both designs: high levels of proximal bone loss and distal bone densification. The results suggest this novel computational framework can be utilized for comparative hip prosthesis shape, uniquely considering the post-operation bone remodeling as a design criterion. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Increasing risk of prosthetic joint infection after total hip arthroplasty

    DEFF Research Database (Denmark)

    Dale, Håvard; Fenstad, Anne M; Hallan, Geir

    2012-01-01

    Background and purpose The risk of revision due to infection after primary total hip arthroplasty (THA) has been reported to be increasing in Norway. We investigated whether this increase is a common feature in the Nordic countries (Denmark, Finland, Norway, and Sweden). Materials and methods The...... explain this increase. We believe that there has been an actual increase in the incidence of prosthetic joint infections after THA.......Background and purpose The risk of revision due to infection after primary total hip arthroplasty (THA) has been reported to be increasing in Norway. We investigated whether this increase is a common feature in the Nordic countries (Denmark, Finland, Norway, and Sweden). Materials and methods...... The study was based on the Nordic Arthroplasty Register Association (NARA) dataset. 432,168 primary THAs from 1995 to 2009 were included (Denmark: 83,853, Finland 78,106, Norway 88,455, and Sweden 181,754). Adjusted survival analyses were performed using Cox regression models with revision due to infection...

  4. Artroplastia total coxofemoral em cães: Estudo experimental com prótese nacional Total hip arthroplasty in dogs: Experimental study using a prosthesis made in Brazil

    Directory of Open Access Journals (Sweden)

    Bruno Watanabe Minto

    2008-02-01

    Full Text Available A prótese total da articulação coxofemoral representa uma das técnicas mais aceitas, nos Estados Unidos e na Europa, para o tratamento cirúrgico da displasia coxofemoral severa em cães. Entretanto, ainda é pouco difundida e estudada no Brasil. No presente trabalho, foi utilizada prótese confeccionada no Brasil, com o objetivo de avaliar a sua aplicação, evolução pós-operatória e complicações associadas. Foram utilizados dez cães, sadios e adultos. Todos foram submetidos ao procedimento de prótese total cimentada da articulação esquerda utilizando-se um componente femoral de cromo-cobalto, cabeça fixa, e uma cúpula acetabular de polietileno de alta densidade. As avaliações clínicas e radiográficas foram realizadas no pré-operatório e aos 30, 60, 90, 120 e 150 dias após a intervenção cirúrgica. A prótese total utilizada proporcionou um bom resultado funcional ao membro operado, em 80% dos animais. As principais complicações relacionadas foram a luxação protética e a soltura do componente acetabular.Total hip prosthesis is one of the most accepted methods used in the United States and Europe for the treatment of severe hip dysplasia in dogs. However, there are few studies with the technique and the procedure is still not well established in Brazil. A prosthesis made in Brazil was used. The purpose of this study was to evaluate its application and determine the postoperative finds and complications. Ten mature healthy dogs were used. A fixed-head cemented total hip prosthesis was applied on the left leg of the dogs. A chrome-cobalt femoral stem and high density polyetylene acetabular cup was used. Clinical and radiographic evaluations were performed before surgery and again at 30, 60, 90, 120 e 150 days post operation. Proper weight bearing was noticed on the operated limb in the majority of the dogs. The main complications were the dislocation and loosening of the acetabular cup.

  5. A predictive model for early mortality after surgical treatment of heart valve or prosthesis infective endocarditis. The EndoSCORE.

    Science.gov (United States)

    Di Mauro, Michele; Dato, Guglielmo Mario Actis; Barili, Fabio; Gelsomino, Sandro; Santè, Pasquale; Corte, Alessandro Della; Carrozza, Antonio; Ratta, Ester Della; Cugola, Diego; Galletti, Lorenzo; Devotini, Roger; Casabona, Riccardo; Santini, Francesco; Salsano, Antonio; Scrofani, Roberto; Antona, Carlo; Botta, Luca; Russo, Claudio; Mancuso, Samuel; Rinaldi, Mauro; De Vincentiis, Carlo; Biondi, Andrea; Beghi, Cesare; Cappabianca, Giangiuseppe; Tarzia, Vincenzo; Gerosa, Gino; De Bonis, Michele; Pozzoli, Alberto; Nicolini, Francesco; Benassi, Filippo; Rosato, Francesco; Grasso, Elena; Livi, Ugolino; Sponga, Sandro; Pacini, Davide; Di Bartolomeo, Roberto; De Martino, Andrea; Bortolotti, Uberto; Onorati, Francesco; Faggian, Giuseppe; Lorusso, Roberto; Vizzardi, Enrico; Di Giammarco, Gabriele; Marinelli, Daniele; Villa, Emmanuel; Troise, Giovanni; Picichè, Marco; Musumeci, Francesco; Paparella, Domenico; Margari, Vito; Tritto, Francesco; Damiani, Girolamo; Scrascia, Giuseppe; Zaccaria, Salvatore; Renzulli, Attilio; Serraino, Giuseppe; Mariscalco, Giovanni; Maselli, Daniele; Foschi, Massimiliano; Parolari, Alessandro; Nappi, Giannantonio

    2017-08-15

    The aim of this large retrospective study was to provide a logistic risk model along an additive score to predict early mortality after surgical treatment of patients with heart valve or prosthesis infective endocarditis (IE). From 2000 to 2015, 2715 patients with native valve endocarditis (NVE) or prosthesis valve endocarditis (PVE) were operated on in 26 Italian Cardiac Surgery Centers. The relationship between early mortality and covariates was evaluated with logistic mixed effect models. Fixed effects are parameters associated with the entire population or with certain repeatable levels of experimental factors, while random effects are associated with individual experimental units (centers). Early mortality was 11.0% (298/2715); At mixed effect logistic regression the following variables were found associated with early mortality: age class, female gender, LVEF, preoperative shock, COPD, creatinine value above 2mg/dl, presence of abscess, number of treated valve/prosthesis (with respect to one treated valve/prosthesis) and the isolation of Staphylococcus aureus, Fungus spp., Pseudomonas Aeruginosa and other micro-organisms, while Streptococcus spp., Enterococcus spp. and other Staphylococci did not affect early mortality, as well as no micro-organisms isolation. LVEF was found linearly associated with outcomes while non-linear association between mortality and age was tested and the best model was found with a categorization into four classes (AUC=0.851). The following study provides a logistic risk model to predict early mortality in patients with heart valve or prosthesis infective endocarditis undergoing surgical treatment, called "The EndoSCORE". Copyright © 2017. Published by Elsevier B.V.

  6. TWO-STAGE REVISION HIP REPLACEMENT PATIENS WITH SEVERE ACETABULUM DEFECT (CASE REPORT

    Directory of Open Access Journals (Sweden)

    V. V. Pavlov

    2017-01-01

    Full Text Available Favorable short-term results of arthroplasty are observed in 80–90% of cases, however, over the longer follow up period the percentage of positive outcomes is gradually reduced. Need for revision of the prosthesis or it’s components increases in proportion to time elapsed from the surgery. In addition, such revision is accompanied with a need to substitute the bone defect of the acetabulum. As a solution the authors propose to replace pelvic defects in two stages. During the first stage the defect was filled with bone allograft with platelet-rich fibrin (allografting with the use of PRF technology. After the allograft remodeling during the second stage the revision surgery is performed by implanting standard prostheses. The authors present a clinical case of a female patient with aseptic loosening of acetabular component of prosthesis in the right hip joint, with failed hip function of stage 2, right limb shortening of 2 cm. Treatment results confirm the efficiency and rationality of the proposed bone grafting option. The authors conclude bone allograft in combination with the PRF technology proves to be an alternative to the implantation of massive metal implants in the acetabulum while it reduces the risk of implant-associated infection, of metallosis in surrounding tissues and expands further revision options.

  7. Primary extra-cranial meningioma following total hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, T.J.; Beggs, I. [Royal Infirmary, Department of Radiology, Edinburgh (United Kingdom); Patton, J.T.; Porter, D. [Royal Infirmary, Department of Orthopaedics, Edinburgh (United Kingdom); Salter, D.M.; Al-Nafussi, A. [Royal Infirmary, Department of Pathology, Edinburgh (United Kingdom)

    2009-01-15

    A 61-year-old man presented with pain at the left hip and decreased mobility 10 years after total hip replacement. Imaging demonstrated a large destructive expansile mass adjacent to the prosthesis. Histological analysis confirmed the presence of an extra-cranial meningioma. Primary tumours after total hip replacement are rare and include soft tissue sarcomas, bone sarcomas and lymphomas. To our knowledge, no previous cases of primary extracranial meningioma have been identified. The imaging features, histology, pathogenesis and differential diagnosis are discussed. (orig.)

  8. Mid term results of Furlong LOL uncemented hip hemiarthroplasty for fractures of the femoral neck.

    Science.gov (United States)

    Chandran, Prakash; Azzabi, Mohammed; Burton, Dave J C; Andrews, Mark; Bradley, John G

    2006-08-01

    We report the mid-term results of hemiarthroplasty with the Furlong hydroxyapatite coated bipolar prosthesis for displaced (Garden type III and IV) intracapsular hip fracture in 480 patients operated between 1989 and 2000. Three hundred sixty eight (77%) patients were lost to follow-up due to death, dementia or movement away from the area. In the patients followed up there was an 8% reoperation rate for infection, aseptic loosening, periprosthetic fracture and acetabular erosion. One hundred and twelve patients with a mean follow-up of 4 years (3-14) were studied. Eighty eight percent had no or slight pain, 77% could mobilise outdoors and 89% needed either no aid or a single walking stick to mobilise. Radiographic assessment revealed a stable implant with visible osseointegration in 91%. We conclude that hemiarthroplasty with the hydroxyapatite coated bipolar Furlong LOL prosthesis for displaced intracapsular fracture of the neck of the femur gives good mid term results in elderly patients for return to mobility, use of mobility aids and freedom from pain. It avoids the need for cement and provides satisfactory incorporation into the host bone. The use of a modular head makes revision to total hip replacement easier.

  9. Revision for prosthetic joint infection following hip arthroplasty: Evidence from the National Joint Registry.

    Science.gov (United States)

    Lenguerrand, E; Whitehouse, M R; Beswick, A D; Jones, S A; Porter, M L; Blom, A W

    2017-06-01

    We used the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) to investigate the risk of revision due to prosthetic joint infection (PJI) for patients undergoing primary and revision hip arthroplasty, the changes in risk over time, and the overall burden created by PJI. We analysed revision total hip arthroplasties (THAs) performed due to a diagnosis of PJI and the linked index procedures recorded in the NJR between 2003 and 2014. The cohort analysed consisted of 623 253 index primary hip arthroplasties, 63 222 index revision hip arthroplasties and 7585 revision THAs performed due to a diagnosis of PJI. The prevalence, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression. We demonstrated a prevalence of revision THA due to prosthetic joint infection of 0.4/100 procedures following primary and 1.6/100 procedures following revision hip arthroplasty. The prevalence of revision due to PJI in the three months following primary hip arthroplasty has risen 2.3-fold (95% confidence interval (CI) 1.3 to 4.1) between 2005 and 2013, and 3.0-fold (95% CI 1.1 to 8.5) following revision hip arthroplasty. Over 1000 procedures are performed annually as a consequence of hip PJI, an increase of 2.6-fold between 2005 and 2013. Although the risk of revision due to PJI following hip arthroplasty is low, it is rising and, coupled with the established and further predicted increased incidence of both primary and revision hip arthroplasty, this represents a growing and substantial treatment burden. Cite this article : E. Lenguerrand, M. R. Whitehouse, A. D. Beswick, S. A. Jones, M. L. Porter, A. W. Blom. Revision for prosthetic joint infection following hip arthroplasty: Evidence from the National Joint Registry. Bone Joint Res 2017;6:391-398. DOI: 10.1302/2046-3758.66.BJR-2017-0003.R1. © 2017 Lenguerrand et al.

  10. Cirurgia conservadora de próteses aórtica e mitral na endocardite infecciosa Conservative surgery for aortic and mitral prosthesis in infective endocarditis

    Directory of Open Access Journals (Sweden)

    Kanim Kalil KASSAB

    2001-03-01

    Full Text Available A endocardite infecciosa (EI acometendo próteses valvares é uma complicação freqüente, sendo tratada geralmente com cirurgia, devido ao seu difícil controle clínico e má resposta à antibioticoterapia. Este relato descreve o caso de uma paciente com EI, acometendo simultaneamente as biopróteses aórtica (Ao e mitral (Mi após vinte e quatro meses de cirurgia de implantes valvares, submetida a tratamento cirúrgico conservador, e com resultado favorável. Discutem-se as vantagens deste procedimento em situações específicas.Infective endocarditis is a frequent complication for valvar prosthesis currently treated with surgery, orving to its difficult control and poor response to therapy with antibiotics. Although conservative surgery for infective endocarditis of prosthesis is not a procedure of choice, this report shows a case of infective endocarditis of aortic and mitral prosthesis, after 24 months of implantation, treated by conservative surgery with favorable outcome.

  11. Total hip reconstruction in acetabular dysplasia.

    NARCIS (Netherlands)

    Schller, H.M.; Dalstra, M.; Huiskes, R.; Marti, R.K.

    1993-01-01

    In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found

  12. Stability Loss of the Cemented Stem of Hip Prosthesis due to Fretting Corrosion Fatigue

    Directory of Open Access Journals (Sweden)

    L. Capitanu

    2017-12-01

    Full Text Available Aim of this project was to study the fretting behaviour of the cemented femoral stem fixation of a total hip prosthesis, trying to capture the loss of contact between the femoral stem and polymetylmethacrilate cement fixation. To have a landmark, studies were performed compared with cementless fixation, where no fretting phenomenon occurs, on real prostheses, under biological 3D loading conditions. A fatigue test device, installed on a servo-hydraulic triaxial dynamic testing machine was used. It allowed monitoring the flexion-extension, abduction-adduction, inner-outer rotation movements, and the variation of the torsional torque, depending on normal loading. The test ends when the sample does not fail after 2000000 cycles, or when it has reached a predetermined number of cycles. Test fluid medium used was NaCl mixed with distilled water, a favourable environment for appearance of fretting corrosion. After the failure of stem fixation at 2450000 cycles, the mantle of bone cement remaining adherent on femoral stem was removed. Microscopic inspection of the femoral stem and of the inner part of the polymetylmethacrilate mantle demonstrated the existence of corrosion of the femoral stem surface beneath the cement mantle, and Fe2O3 deposits on the femoral stem surface and on the inner part of the mantle.

  13. SU-E-T-612: Photonuclear Activation of Prosthetic Hips in Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Keehan, S; Taylor, M; Franich, R [RMIT University, Melbourne, VIC (Australia); Smith, R; Millar, J; Esser, M [William Buckland Radiotherapy Centre, Melbourne, VIC (Australia); Kron, T [Peter MacCallum Cancer Instit., Melbourne (Australia)

    2015-06-15

    Purpose: To measure the neutron induced activation of a prosthetic hip when exposed to an 18 MV radiotherapy linac beam to assess the potential dose to patients. Methods: A prosthetic hip (Thackray, UK) was placed in a water phantom and irradiated (both in-field and out-of-field) with an 18 MV linac beam. Gamma spectroscopy was used to identify the radioisotopes produced. Following the in-field irradiation where the induced activity is higher, high sensitivity lithium fluoride Thermoluminescence Dosimeters (TLD-100H) (Harshaw, USA) were placed on the surface to measure the dose which would be deposited to nearby tissue resulting from the induced radioactivity. Results: The radioisotopes produced in the hip prosthesis have been identified as {sup 5{sup 2}}V, {sup 5{sup 3}}Fe, and {sup 56}Mn which have half-lives of 3.74, 8.51 and minutes respectively. The 378 and 511 keV characteristic peaks of {sup 5{sup 3}}Fe do not appear in the spectra collected from hips irradiated in the out-of-field region. This isotope is produced by photonuclear interactions within the hip itself. {sup 52}V and {sup 56}Mn appear in spectra collected from hips irradiated either within the photon beam or in the nearby out-of-field region, implying that they are produced by incident neutron radiation produced in components of the linear accelerator.The integrated dose which would be deposited in the tissue immediately surrounding the hip after four hours (1.5 half-lives of the longest lived product) was measured as approximately 100 µGy, following a 10,000 MU irradiation of the prosthesis. A highly accurate measurement of the dose is challenging because of the irregular shape of the prosthesis. Conclusion: The cumulative dose measured at the surface of the hip is 0.0001% of the in-field dose, and is therefore negligible compared with the doses the patient receives as a consequence of their treatment.

  14. Design of compensators for patients with hip prostheses undergoing pelvic irradiation

    International Nuclear Information System (INIS)

    Alecu, R.; Feldmeier, J.; He, T.; Alecu, M.; Court, W.; Orton, C.G.

    1995-01-01

    The perturbations in the dose distribution caused by a hip prosthesis when treating pelvic cancers have been evaluated and found to be significant by several investigators. Treatment techniques not including the prosthesis are often not the best choice. The goal of this study is to investigate the feasibility and usefulness of design of compensators in routine clinical practice for any kind of hip prosthesis. The calculation procedures and the algorithms developed by the authors for generating the compensators are described for two systems: one based on a locally developed 3-D computerized treatment planning system and an other one practicable in any institution which does not have access to a 3D treatment planning system or CT. The methodology to create the compensators for a patient is explained. To evaluate the constructed compensators in phantom and in vivo measurements were performed. The results are presented along with a comparison between the two methods

  15. Enhanced lubricant film formation through micro-dimpled hard-on-hard artificial hip joint: An in-situ observation of dimple shape effects.

    Science.gov (United States)

    Choudhury, Dipankar; Rebenda, David; Sasaki, Shinya; Hekrle, Pavel; Vrbka, Martin; Zou, Min

    2018-05-01

    This study evaluates the impact of dimple shapes on lubricant film formation in artificial hip joints. Micro-dimples with 20-50 µm lateral size and 1 ± 0.2 µm depths were fabricated on CrCoMo hip joint femoral heads using a picosecond laser. Tribological studies were performed using a pendulum hip joint simulator to apply continuous swing flexion-extension motions. The results revealed a significantly enhanced lubricant film thickness (≥ 500 nm) with micro-dimpled prosthesis heads at equilibrium position after the lubricant film has fully developed. The average lubricant film thickness of dimpled prostheses with square- and triangular-shaped dimple arrays over time is about 3.5 that of the non-dimpled prosthesis (204 nm). Remarkably, the prosthesis with square-shaped dimple arrays showed a very fast lubricant film formation reaching their peak values within 0.5 s of pendulum movement, followed by prosthesis with triangular-shaped dimple arrays with a transition period of 42.4 s. The fully developed lubricant film thicknesses (≥ 700 nm) are significantly higher than the surface roughness (≈ 25 nm) demonstrating a hydrodynamic lubrication. Hardly any scratches appeared on the post-experimental prosthesis with square-shaped dimple array and only a few scratches were found on the post-experimental prosthesis with triangular-shaped dimple arrays. Thus, prostheses with square-shaped dimple arrays could be a potential solution for durable artificial hip joints. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Reverse hybrid total hip arthroplasty

    DEFF Research Database (Denmark)

    Wangen, Helge; Havelin, Leif I.; Fenstad, Anne M

    2017-01-01

    Background and purpose - The use of a cemented cup together with an uncemented stem in total hip arthroplasty (THA) has become popular in Norway and Sweden during the last decade. The results of this prosthetic concept, reverse hybrid THA, have been sparsely described. The Nordic Arthroplasty....... Patients and methods - From the NARA, we extracted data on reverse hybrid THAs from January 1, 2000 until December 31, 2013. 38,415 such hips were studied and compared with cemented THAs. The Kaplan-Meier method and Cox regression analyses were used to estimate the prosthesis survival and the relative risk...

  17. Acinetobacter Prosthetic Joint Infection Treated with Debridement and High-Dose Tigecycline.

    Science.gov (United States)

    Vila, Andrea; Pagella, Hugo; Amadio, Claudio; Leiva, Alejandro

    2016-12-01

    Prosthesis retention is not recommended for multidrug-resistant Acinetobacter prosthetic joint infection due to its high failure rate. Nevertheless, replacing the prosthesis implies high morbidity and prolonged hospitalization. Although tigecycline is not approved for the treatment of prosthetic joint infection due to multidrug resistant Acinetobacter baumannii, its appropriate use may preclude prosthesis exchange. Since the area under the curve divided by the minimum inhibitory concentration is the best pharmacodynamic predictor of its efficacy, we used tigecycline at high dose, in order to optimize its efficacy and achieve implant retention in 3 patients who refused prosthesis exchange. All patients with prosthetic joint infections treated at our Institution are prospectively registered in a database. Three patients with early prosthetic joint infection of total hip arthroplasty due to multidrug resistant A. baumannii were treated with debridement, antibiotics and implant retention, using a high maintenance dose of tigecycline (100 mg every 12 hours). The cases were retrospectively reviewed. All patients signed informed consent for receiving off-label use of tigecycline. Tigecycline was well tolerated, allowing its administration at high maintenance dose for a median of 40 days (range 30-60). Two patients were then switched to minocycline at standard doses for a median of 3.3 months in order to complete treatment. Currently, none of the patients showed relapse. Increasing the dose of tigecycline could be considered as a means to better attain pharmacodynamic targets in patients with severe or difficult-to-treat infections. Tigecycline at high maintenance dose might be useful when retention of the implant is attempted for treatment for prosthetic joint infections due to multidrug resistant Acinetobacter. Although this approach might be promising, off-label use of tigecycline should be interpreted cautiously until prospective data are available. Tigecycline is

  18. Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

    Directory of Open Access Journals (Sweden)

    Gholam Hossein Shahcheraghi

    2015-09-01

    Full Text Available Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations. Methods: 52 primary cementless total hip arthroplasty in 42 patients with the mean age of 48.8 years were retrospectively studied. Two groups of prosthesis had been implanted: Harris-Galante II (HGII in 15 and Versys-Trilogy (V-T in 37 hips, both from Zimmer company. The patients were assessed clinically, radiographically and with Harris hip score, SF36, WOMAC, and MACTAR questionnaires, with 65 months (26-136 mean follow-up. Results: All the V-T prostheses had survived well. Eight of HG II were revised by the last follow-up in 19-102 months. All had undergone acetabular revision and 2 combined with femoral revision. Broken tines of HGII cups were seen in 4 radiographs. The 65 months overall survival was 96.2% for femoral and 84.6% for acetabular components. 90% had good or excellent Harris hip scores. The functional scores were poorer in the HG II group. Pain relief and improved walking were the two main patients’ expectations fulfilled in 97.6% and 92.8%, respectively. Conclusions: The outcome of cementless total hip arthroplasty (THA is satisfactory and comparable with the literature based on the results of function and survival of this small comparative group. The use of HGII acetabular component should be abandoned.

  19. The use of interlocking prostheses for both temporary and definitive management of infected periprosthetic femoral fractures.

    Science.gov (United States)

    Konan, Sujith; Rayan, Faizal; Manketelow, Andrew R J; Haddad, Fares S

    2011-12-01

    Infected periprosthetic fractures around total hip arthroplasties are an extremely challenging problem. We describe our experience of managing infected periprosthetic femoral fractures using interlocking long-stem femoral prostheses either as temporary functional spacers or as definitive implants. The Cannulock (Orthodesign, Christchurch, United Kingdom) uncoated stem was used in 12 cases, and the Kent hip prosthesis (Biomet Merck, Bridgend, United Kingdom), in 5 cases. Satisfactory outcome was noted in all cases, and in 11 cases, revision to a definitive stem has been undertaken after successful control of infection and fracture union. The use of interlocking stems offers a relatively appealing solution for a complex problem and avoids the complications that would be associated with resection of the entire femur or the use of large quantities of bone cement. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Heavy reading in heavy metal : Unraveling the mystery of hip tissue in metal on metal total hip arthroplasty

    NARCIS (Netherlands)

    Boomsma, M.F.

    2017-01-01

    In this thesis, we investigated the use of computer tomography (CT) for the screening of patients with a metal-on-metal (MoM) hip prosthesis in two patient cohorts. With a self-established CT grading scale, we have shown that CT is a reliable method for the diagnosis of postoperative pathological

  1. An experimental-numerical method for comparative analysis of joint prosthesis

    International Nuclear Information System (INIS)

    Claramunt, R.; Rincon, E.; Zubizarreta, V.; Ros, A.

    2001-01-01

    The difficulty that exists in the analysis of mechanical stresses in bones is high due to its complex mechanical and morphological characteristics. This complexity makes generalists modelling and conclusions derived from prototype tests very questionable. In this article a relatively simple comparative analysis systematic method that allow us to establish some behaviour differences in different kind of prosthesis is presented. The method, applicable in principle to any joint problem, is based on analysing perturbations produced in natural stress states of a bone after insertion of a joint prosthesis and combines numerical analysis using a 3-D finite element model and experimental studies based on photoelastic coating and electric extensometry. The experimental method is applied to compare two total hip prosthesis cement-free femoral stems of different philosophy. One anatomic of new generation, being of oblique setting over cancellous bone and the other madreporique of trochantero-diaphyseal support over cortical bone. (Author) 4 refs

  2. Wear mechanisms in ceramic hip implants.

    Science.gov (United States)

    Slonaker, Matthew; Goswami, Tarun

    2004-01-01

    The wear in hip implants is one of the main causes for premature hip replacements. The wear affects the potential life of the prosthesis and subsequent removals of in vivo implants. Therefore, the objective of this article is to review various joints that show lower wear rates and consequently higher life. Ceramics are used in hip implants and have been found to produce lower wear rates. This article discusses the advantages and disadvantages of ceramics compared to other implant materials. Different types of ceramics that are being used are reviewed in terms of the wear characteristics, debris released, and their size together with other biological factors. In general, the wear rates in ceramics were lower than that of metal-on-metal and metal-on-polyethylene combinations.

  3. Short-Term Effect of Prosthesis Transforming Sensory Modalities on Walking in Stroke Patients with Hemiparesis

    Science.gov (United States)

    Sekiguchi, Yusuke; Honda, Keita; Ishiguro, Akio

    2016-01-01

    Sensory impairments caused by neurological or physical disorders hamper kinesthesia, making rehabilitation difficult. In order to overcome this problem, we proposed and developed a novel biofeedback prosthesis called Auditory Foot for transforming sensory modalities, in which the sensor prosthesis transforms plantar sensations to auditory feedback signals. This study investigated the short-term effect of the auditory feedback prosthesis on walking in stroke patients with hemiparesis. To evaluate the effect, we compared four conditions of auditory feedback from plantar sensors at the heel and fifth metatarsal. We found significant differences in the maximum hip extension angle and ankle plantar flexor moment on the affected side during the stance phase, between conditions with and without auditory feedback signals. These results indicate that our sensory prosthesis could enhance walking performance in stroke patients with hemiparesis, resulting in effective short-term rehabilitation. PMID:27547456

  4. Dislocation of total hip replacement in patients with fractures of the femoral neck

    OpenAIRE

    Enocson, Anders; Hedbeck, Carl-Johan; Tidermark, Jan; Pettersson, Hans; Ponzer, Sari; Lapidus, Lasse J

    2009-01-01

    Background Total hip replacement is increasingly used in active, relatively healthy elderly patients with fractures of the femoral neck. Dislocation of the prosthesis is a severe complication, and there is still controversy regarding the optimal surgical approach and its influence on stability. We analyzed factors influencing the stability of the total hip replacement, paying special attention to the surgical approach. Patients and methods We included 713 consecutive hips in a series of 698 p...

  5. Staged Custom, Intramedullary Antibiotic Spacers for Severe Segmental Bone Loss in Infected Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Atul F. Kamath

    2011-01-01

    Full Text Available Introduction. Total hip arthroplasty (THA infections with severe bone loss pose significant reconstructive challenges. We present our experience with two-stage hip reimplantation using an intramedullary, antibiotic-impregnated nail. Methods. Three patients with infected THA with severe proximal femoral bone loss (Mallory type IIIB or greater were treated using a custom antibiotic spacer. Clinical outcomes and any complications were recorded. Average followup was 49 months from final reimplantation. Results. Mean age at spacer placement (stage 1 was 53 years. The mean Harris Hip Score at final followup was 80. Two patients had asymptomatic heterotopic ossification, and one patient had a 2 cm leg-length discrepancy. Conclusions. A custom intramedullary nail antibiotic spacer is a reliable option in the staged management of the infected THA with severe proximal femoral bone loss. Benefits of this technique include limb salvage with maintenance of leg length, soft tissue tension, and functional status.

  6. [Distal fixation prosthesis for unstable intertrochanteric fractures in elderly patients: a mid-term follow-up study].

    Science.gov (United States)

    Zhang, Zhan-feng; Min, Ji-kang; Zhong, Jian-ming; Wang, Dan

    2016-06-01

    To explore mid-term follow up results of distal fixation prosthesis in treating unstable intertrochanteric fractures in elderly patients. From May 2008 to March 2014,58 elderly patients with unstable intertrochanteric were treated with distal fixation prosthesis, among them, there were 15 males and 43 females aged from 75 to 87 years old with an average of 83.2 years old. Fracture were classified according to Evans classification, 39 cases were type I c and 19 cases were type I d. Surgical risk was evaluated before operation, 9 patients were performed total hip arthroplasty and 49 patients were performed prosthetic replacement hip joint function of patients with different age period, Evans classificaton, prothesis type, fixation method were evaluated respectively by using Harris score. Fifty-six patients were followed up from 13 to 36 months with an average of 21.6 months. Harris score was 83.51 ± 6.40, 5 cases got excellent results, 38 cases good and 13 cases moderate. Harris score of patients aged from 75 to 80 years old was 88.64 ± 2.35, 81.64 ± 6.40 in patients aged more than 80 years old, and had significant differences between two groups; Harris score in patients with type Evans I c was 83.64 ± 6.53, and 83.11 ± 6.08 in type Evans I d, while there was no significant differences between two groups. There was no obvious meaning in Harris score between patients with tension band (83.63 ± 6.15) and without tension band (82.41 ± 6.57). There was no significant meaning in Harris score between patients with normal distal fixation prosthesis (83.34 ± 6.43) and femoral moment reconstruction distal fixation prosthesis (83.92 ± 6.51). There was 1 patient occurred hip joint dislocation on the operative side and re-dislocation after manual reduction, then received open reduction. Two patients occurred femoral osteolysis without clinical symptoms, and treated conservative treatment. Artificial joint replacement for unstable intertrochanteric fractures in elderly

  7. Preoperative irradiation for prevention of heterotopic ossification following prosthetic total hip replacement. Results of a prospective study in 462 hips

    Energy Technology Data Exchange (ETDEWEB)

    Koelbl, O.; Seufert, J.; Pohl, F.; Flentje, M. [Univ. Wuerzburg (Germany). Klinik and Poliklinik for Radiotherapy; Tauscher, A.; Springorum, H.W. [Caritas Hospital, Bad Mergentheim (Germany). Orthopedic Clinic; Lehmann, H. [Caritas Hospital, Bad Mergentheim (Germany). Inst. of Radiology

    2003-11-01

    Background: The effectiveness of pre- or postoperative radiotherapy for prevention of heterotopic ossification (HO) following total hip replacement (THR) has already been demonstrated in the past. Thereby, in most studies using preoperative radiotherapy patients were irradiated < 6 h before surgery. The purpose of this prospective study was to analyze the effectiveness of preoperative irradiation on the evening before surgery and to identify risk factors for HO in a homogeneous collective of patients. Patients and Methods: From July 1997 to July 2001, 416 patients (462 hips; 235 males, 227 females) received preoperative radiotherapy of the hip on the evening before surgery with a 7-Gy single fraction. The patients' median age was 67.1 years. The most frequent indication for radiotherapy was hypertrophic osteoarthritis (383 hips, 82.9%). Treatment results were assessed by comparison of pre- and postoperative hip X-rays (immediately and 6 months after surgery). The analysis of radiographs was performed according to the Brooker score. Results: The overall incidence of HO was 18.1% (n = 84), Brooker score 1 12.3% (n = 57), score 2 3.9% (n = 18), score 3 1.5% (n = 7), and score 4 0.4% (n = 2). Sex, body height, hypertrophic osteoarthritis of higher degree, size of the femoral component of the prosthesis, previous ipsi- or contralateral HO, and short course of nonsteroidal anti-inflammatory drug (diclofenac) therapy significantly influenced the HO rate in univariate analysis. In multivariate analysis, an interdependence of prosthesis size, sex and patient's height was found. From these three variables, only prosthesis size was statistically significant in multivariate analysis. The cumulative dose of diclofenac ({<=} 300 mg or > 300 mg) within the first 7 postoperative days and previous ipsi- or contralateral HO influenced the incidence of HO in multivariate analysis. Conclusion: Preoperative radiotherapy on the evening before surgery is an effective treatment

  8. A Stereophotogrammetric System For The Detection Of Prosthesis Loosening In Total Hip Arthroplasty

    Science.gov (United States)

    Baumrind, Sheldon; Genant, Harry K.; Hunter, John; Miller, David; Moffitt, Francis; Murray, William R.; Ross, Steven E.

    1980-07-01

    Loosening of the prosthetic device occurs in about 5% of cases following placement of total hip prostheses (THP). Early detection of loosening is much desired but is difficult to achieve using conventional methods. Due to errors of projection, it is quite possible to fail to detect mobility of even as much as 5 mm on single x-ray films. We are attempting to develop a simplified photogrammetric system suitable for general hospital use which could detect loosening of 0.8 mm at the 95 % level of confidence without use of complex stereoplotting equipment. Metal reference markers are placed in the shaft of the femur and in the acetabular region of the pelvis at the time of surgery. The distances between these reference markers and certain unambiguous points on the prostheses are computed analytically using an X-Y acoustical digitizer (accuracy ± 0.1 mm) and software developed previously for craniofacial measurement. Separate stereopairs of the joint region are taken under weight-bearing and nonweight-bearing conditions. Differences in the measured distances between the bo-ne markers and the prosthetic components on the two stereopairs are taken as indicators of prosthesis loosening. Measurements on a phantom using ten different x-ray stereopairs taken from as many different perspectives have established that true linear distances between reference points and prostheses can be measured at the desired reliability with the present low precision system. Preliminary in vivo measurements indicate that the main unresolved problem is the movement of the subject between the two exposures of each single stereopair. Two possible solutions to this problem are discussed.

  9. Granulicatella adiacens prosthetic hip joint infection after dental treatment.

    Science.gov (United States)

    Aweid, Osama; Sundararajan, Sabapathy; Teferi, Abraham

    2016-06-01

    Granulicatella adiacens is a Gram-positive bacteria and a normal component of oral flora. It is also found in dental plaques, endodontic abscesses and can rarely cause more serious infections. We describe a prosthetic hip joint infection in an 81-year-old fit and healthy man due to Granulicatella adiacens who underwent a prolonged dental intervention two days earlier without antibiotic prophylaxis. The infection was successfully treated with surgical intervention and a combination of antibiotics. The patient eventually succumbed to severe community-acquired pneumonia two months later. Current guidelines recommend avoidance of antibiotic prophylaxis prior to dental treatment in patients who have no co-morbidities and no prior operation on the index prosthetic joint. This case report indicates that infections of prosthetic joints may be associated with dental procedures even in fit and healthy patients without the recognized risk factors.

  10. A Review of Periprosthetic Femoral Fractures Associated With Total Hip Arthroplasty

    Science.gov (United States)

    Marsland, Daniel; Mears, Simon C.

    2012-01-01

    Periprosthetic fractures of the femur in association with total hip arthroplasty are increasingly common and often difficult to treat. Patients with periprosthetic fractures are typically elderly and frail and have osteoporosis. No clear consensus exists regarding the optimal management strategy because there is limited high-quality research. The Vancouver classification facilitates treatment decisions. In the presence of a stable prosthesis (type-B1 and -C fractures), most authors recommend surgical stabilization of the fracture with plates, strut grafts, or a combination thereof. In up to 20% of apparent Vancouver type-B1 fractures, the femoral stem is loose, which may explain the high failure rates associated with open reduction and internal fixation. Some authors recommend routine opening and dislocation of the hip to perform an intraoperative stem stability test to rule out a loose component. Advances in plating techniques and technology are improving the outcomes for these fractures. For fractures around a loose femoral prosthesis (types B2 and 3), revision using an extensively porous-coated uncemented long stem, with or without additional fracture fixation, appears to offer the most reliable outcome. Cement-in-cement revision using a long-stem prosthesis is feasible in elderly patients with a well-fixed cement mantle. It is essential to treat the osteoporosis to help fracture healing and to prevent further fractures. We provide an overview of the causes, classification, and management of periprosthetic femoral fractures around a total hip arthroplasty based on the current best available evidence. PMID:23569704

  11. Reliability analysis for cementless hip prosthesis using a new optimized formulation of yield stress against elasticity modulus relationship

    International Nuclear Information System (INIS)

    Kharmanda, G.

    2015-01-01

    Highlights: • We develop a new formulation between the yield stress and Young’s modulus of bone. • We validate the optimized formulation for cortical and trabecular bone. • We integrate the reliability analysis into artificially hip replacement design. - Abstract: Using classical design optimization methods for implant-bone studies does not completely guarantee a safety and satisfactory performance, due in part to the randomness of bone properties and loading. Here, the material properties of the different bone layers are considered as uncertain parameters. So their corresponding yield stress values will not be deterministic, that leads to integrate variable limitations into the optimization process. Here there is a strong need to find a reliable mathematical relationship between yield stress and material properties of the different bone layers. In this work, a new optimized formulation for yield stress against elasticity modulus relationship is first developed. This model is based on some experimental results. A validation of the proposed formulation is next carried out to show its accuracy for both bone layers (cortical and cancellous). A probabilistic sensitivity analysis is then carried out to show the role of each input parameter with respect to the limit state function. The new optimized formulation is next integrated into a reliability analysis problem in order to assess the reliability level of the stem–bone study where we deal with variable boundary limitations. An illustrative application is considered as a bi-dimensional example (contains only two variables) in order to present the results in an illustrative 2D space. Finally, a multi-variable problem considering several daily loading cases on a hip prosthesis shows the applicability of the proposed strategy

  12. Social profile and cost analysis of deep infection following total hip replacement surgery

    Directory of Open Access Journals (Sweden)

    Vera Lucia Frazão

    Full Text Available ABSTRACT OBJECTIVE: To characterize the socio-economic and demographic profile of patients undergoing surgery for revision total hip arthroplasty regarding the diagnosis of deep prosthetic infection. METHODS: Twenty patients were retrospectively studied, admitted in the period between 2009 and 2010 by the Hip Surgery Group with the diagnosis of deep prosthetic infection, whose proposed treatment was surgical. This study was carried out in the presence of the patient by completing two forms applied by the social worker of the Group. RESULTS: In a 20-patient sample, 40% were male, 45% were working age, 50% of patients originated from the capital, 85% depended on benefits, 70% were retired, 60% of patients were from this hospital, and 40% were from other services. The average cost of patients to the public system was R$ 55,821.62 per patient and the total spent on treatment of patients in the study exceeded one million Brazilian reals, totalling R$ 1,116,432.40. CONCLUSION: Infection from total hip arthroplasty generates a major expense to the social security system and to the public healthcare system. Physicians must always be alert to the possible risk factors and perioperative care, striving to minimize this complication.

  13. Bioball universal modular neck adapter as a salvage for failed revision total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Raju Vaishya

    2013-01-01

    Full Text Available Management of recurrent dislocation of total hip arthroplasty is often a challenging and daunting task. Re-revision of such a total hip prosthesis may not be easy as the removal of a well-fixed, fully coated stem is extremely difficult. We managed to salvage instability in three revision hip cases in which the fully coated stem had subsided by using a bioball universal neck adapter without changing the femoral stem or acetabular cup.

  14. The Current State of Screening and Decolonization for the Prevention of Staphylococcus aureus Surgical Site Infection After Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Weiser, Mitchell C; Moucha, Calin S

    2015-09-02

    The most common pathogens in surgical site infections after total hip and knee arthroplasty are methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant S. aureus (MRSA), and coagulase-negative staphylococci. Patients colonized with MSSA or MRSA have an increased risk for a staphylococcal infection at the site of a total hip or knee arthroplasty. Most colonized individuals who develop a staphylococcal infection at the site of a total hip or total knee arthroplasty have molecularly identical S. aureus isolates in their nares and wounds. Screening and nasal decolonization of S. aureus can potentially reduce the rates of staphylococcal surgical site infection after total hip and total knee arthroplasty. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  15. MRI as a problem-solving tool in unexplained failed total hip replacement following conventional assessment

    International Nuclear Information System (INIS)

    Johnston, Ciaran; Kerr, Jennifer; Ford, Stephanie; Eustace, Stephen; O'Byrne, John

    2007-01-01

    To evaluate MRI as a problem-solving tool for patients with an unexplained failed total hip replacement following conventional radiological assessment. Patients' informed consent was obtained in all cases. Institutional review board approval was obtained. Twenty-eight patients with unexplained failed total hip replacements following conventional radiological assessment underwent additional MR imaging with an optimised turbo-spin echo sequence. Images were reviewed by two musculoskeletal radiologists by consensus and compared with findings at surgery, or following response to image-guided intervention or clinical follow-up. Of the 28 patients, MRI revealed an unsuspected diagnosis explaining the cause of prosthesis failure in 15 patients. In eight of 15 patients in this group, subsequent minimally invasive image-guided intervention obviated the need for revision total hip replacement. No cause for prosthesis failure was identified in 13 patients. MRI may be successfully undertaken in patients following total hip replacement, and, when performed, it frequently leads to an unsuspected diagnosis, allowing informed patient treatment. In this study it allowed the identification of an unsuspected diagnosis in over 50% of cases. (orig.)

  16. Duration and frequency of every day activities in total hip patients.

    Science.gov (United States)

    Morlock, M; Schneider, E; Bluhm, A; Vollmer, M; Bergmann, G; Müller, V; Honl, M

    2001-07-01

    Little knowledge about frequency and duration of daily activities in patients after total hip arthroplasty is available. Such information is required for the definition of realistic load collectives for pre-clinical testing of prostheses. It could also be helpful for the quantitative evaluation of surgery outcome with different prosthesis types. The purpose of this study was to develop and apply a system for the determination of frequency and duration of patient activities in their habitual environment and to compare the results to a clinical outcome score (Harris hip score).A portable activity monitoring system (weight 1.6 kg including batteries) was designed using a Palm top computer, 2 inclination sensors for the thigh and calf and one goniometer positioned at the knee joint. An algorithm was developed to identify frequency and duration of the activities lying, sitting, standing, walking and stair climbing from the signals of the 3 sensors. 42 patients participated in the study and were equipped with the system in the morning at their home. Datasets of 31 patients (age 62.5+/-11.5 y) covered more than 6h (9.8 +/- 1.6 h) and were included in the analysis. Prosthesis specific data as well as the Harris hip score were collected. The most frequent patient activity was sitting (44.3% of the time), followed by standing (24.5%), walking (10.2%), lying (5.8%) and stair climbing (0.4%). The median number of steps/stairs was 6048/164. The number of step cycles representing one year in vivo use should, consequently, be increased to 1.1 million. The Harris hip score (91.4 +/- 9.8) correlated significantly with the number of stairs (r(2) = 0.26, p = 0.003) and showed a positive tendency with the number of steps per day. No differences in activity levels between prosthesis specific factors were found.

  17. Remote transient Lactobacillus animalis bacteremia causing prosthetic hip joint infection: a case report.

    Science.gov (United States)

    Somayaji, R; Lynch, T; Powell, J N; Gregson, D

    2016-11-04

    Lactobacillus spp. are uncommon pathogens in immunocompetent hosts, and even rarer causes of prosthetic device infections. A case of chronic hip prosthetic joint infection (PJI) caused by L. animalis is described. This occurred 5 years after a transient bacteremia with the same organism. Whole genome sequencing of both isolates proved this PJI infection resulted from this remote bacteremia. We document that prosthetic joint infections may be a consequence of bacteremia as much as 3 years before the onset of symptoms.

  18. Bone remodelling of the proximal femur after total hip arthroplasty with 2 different hip implant designs

    DEFF Research Database (Denmark)

    Christiansen, Janus D.; Laursen, Mogens B; Ejaz, Ashir

    2018-01-01

    INTRODUCTION: The thrust plate prosthesis (TPP) was introduced to preserve bone in patients undergoing total hip arthroplasty. We assessed the long-term results of hip arthroplasty in patients who received the TPP compared to a traditional intramedullary stem (Bi-Metric). METHODS......: In this prospective observational cohort study, we evaluated bone mineral density (BMD) using dual-energy X-ray absorptiometry (DXA), radiological imaging and clinical outcome using Harris Hip Score (HHS). Twenty patients received the TPP (group A) and 18 patients received the Bi-Metric stem (group B). Baseline......% (95% confidence interval [CI], 4-16; p = 0.003) and 8% (95% CI, 1-15; p = 0.03) at 8 years. Regarding ROI4, group A had a lesser decrease in general compared to group B. The radiological findings did not reveal any subsidence or detectable implant migration. HHS improved from 53 (23-69) to 93 (55...

  19. Total hip reconstruction in acetabular dysplasia : a finite element study

    NARCIS (Netherlands)

    Schüller, H.M.; Dalstra, M.; Huiskes, H.W.J.; Marti, R.K.

    1993-01-01

    In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found

  20. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Directory of Open Access Journals (Sweden)

    Gavaskar Ashok S

    2012-12-01

    Full Text Available 【Abstract】Total hip arthroplasty (THA for an un-treated acetabular fracture is technically challenging and the long-term result is not so favorable. A 45-year-old fe-male patient with untreated column and comminuted poste-rior wall fracture of the acetabulum was treated in our insti-tution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior col-umn with cancellous grafting and cementless THA in a single stage. At 3 years’ follow-up, the patient was independently mobile without limb length discrepancy. Radiological evalu-ation showed well integrated components and bone grafts. No evidence of aseptic loosening or osteolysis was found. This report aims to emphasize that bony acetabular recon-struction allows the use of primary hip components, which improves prosthesis longevity and preserves bone stock for a future revision. Key words: Acetabulum; Fractures, bone; Hip dislocation; Arthroplasty, replacement, hip

  1. Mechanical analysis of ceramic head for modular hip prosthesis

    International Nuclear Information System (INIS)

    Ravagli, E.

    1995-03-01

    A study, performed with the department of orthopaedics of the Rome Catholic University, has found out the two possible parameters mainly responsible for head breaking, i. e. errors in conical mating between head and stem, and cracks in the heads. This study has been continued in the frame of the STRIDE-CETMA project, aimed at founding and developing a centre for technologically advanced materials in Brindisi Technology Park (Italy). This report starts a systematic mechanical analysis of the above mentioned head, with the purpose of characterizing it exhaustively. The evaluations made lead to the conclusion that in nomimal conditions, the head is largely overdimensioned, taking into account the maximum load applied to the prosthesis

  2. The history of biomechanics in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Jan Van Houcke

    2017-01-01

    Full Text Available Biomechanics of the hip joint describes how the complex combination of osseous, ligamentous, and muscular structures transfers the weight of the body from the axial skeleton into the appendicular skeleton of the lower limbs. Throughout history, several biomechanical studies based on theoretical mathematics, in vitro, in vivo as well as in silico models have been successfully performed. The insights gained from these studies have improved our understanding of the development of mechanical hip pathologies such as osteoarthritis, hip fractures, and developmental dysplasia of the hip. The main treatment of end-stage degeneration of the hip is total hip arthroplasty (THA. The increasing number of patients undergoing this surgical procedure, as well as their demand for more than just pain relief and leading an active lifestyle, has challenged surgeons and implant manufacturers to deliver higher function as well as longevity with the prosthesis. The science of biomechanics has played and will continue to play a crucial and integral role in achieving these goals. The aim of this article, therefore, is to present to the readers the key concepts in biomechanics of the hip and their application to THA.

  3. Remote transient Lactobacillus animalis bacteremia causing prosthetic hip joint infection: a case report

    Directory of Open Access Journals (Sweden)

    R. Somayaji

    2016-11-01

    Full Text Available Abstract Background Lactobacillus spp. are uncommon pathogens in immunocompetent hosts, and even rarer causes of prosthetic device infections. Case presentation A case of chronic hip prosthetic joint infection (PJI caused by L. animalis is described. This occurred 5 years after a transient bacteremia with the same organism. Whole genome sequencing of both isolates proved this PJI infection resulted from this remote bacteremia. Conclusions We document that prosthetic joint infections may be a consequence of bacteremia as much as 3 years before the onset of symptoms.

  4. A Large Rice Body-Containing Cyst Mimicking Infection following Total Hip Arthroplasty: A Case Report

    Directory of Open Access Journals (Sweden)

    Wael Bayoud

    2017-01-01

    Full Text Available Introduction. Soft tissue mass following total hip arthroplasty raises several differential diagnoses not limited to infection, hematoma, wear debris, malignancy, and bursitis. Rice body formation in the hip region is an uncommon process denoting a chronic inflammation. We report here the second case of its kind in the medical literature of a wide symptomatic rice-like body cyst complicating a total hip arthroplasty. Case Presentation. This is the case of an 82-year-old white female, presenting with a warm, red, and inflated groin five years after revision of right total hip arthroplasty. Surgical intervention reveals a large well circumscribed cyst containing well-organized rice-like bodies. This eventuality was never reported in differential diagnosis of hip periprosthetic soft tissue masses before. Conclusion. This case report helps widening the array of the differential diagnosis in patients presenting with a slow growing soft tissue mass following total hip arthroplasty, making rice-like bodies cyst a valid one to consider.

  5. Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses

    NARCIS (Netherlands)

    Wellenberg, R. H. H.; Boomsma, M. F.; van Osch, J. A. C.; Vlassenbroek, A.; Milles, J.; Edens, M. A.; Streekstra, G. J.; Slump, C. H.; Maas, M.

    2017-01-01

    To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer

  6. Adverse reaction to metal debris with concomitant incidental crystalline arthropathy in hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Edward J. Testa, BS

    2017-03-01

    Full Text Available Adverse reaction to metal debris (ARMD is a known cause of failed metal in hip arthroplasty. Diagnosis of this type of prosthesis failure may be difficult, and the hallmark is an abnormally elevated serum cobalt level. Concomitant diagnoses may also be present, such as infection, instability, and loosening, and this may confuse interpretation of abnormal laboratories. We present here, for the first time, 2 patients with ARMD and crystalline arthropathy. In each case, the patient chose surgery for ARMD, with resolution of symptoms and no recurrence of the crystalline arthropathy. We present these cases to alert the orthopaedist that crystalline arthropathy may be present at the same time as ARMD, but is likely not the primary cause of symptoms.

  7. Histologic analysis of a retrieved hydroxyapatite-coated femoral prosthesis

    DEFF Research Database (Denmark)

    Søballe, K; Gotfredsen, K; Brockstedt-Rasmussen, H

    1991-01-01

    A hydroxyapatite-coated hip hemi-prosthesis was retrieved from a 98-year-old osteoporotic woman 12 weeks after implantation. Histologic analysis revealed bone and fibrous tissue almost evenly distributed around the surface of the implant circumference. Quantitative histologic analysis showed...... that 48% of the hydroxyapatite surface was covered by bone. Fibrous tissue covered 30% of the prosthetic surface, and 20% of the surface had no tissue coverage. Scanning electron microscopy showed direct contact without any clear boundary between the newly formed bone and the hydroxyapatite ceramic....

  8. Concomitant achondroplasia and developmental dysplasia of the hip

    Directory of Open Access Journals (Sweden)

    Tennison L. Malcolm, MD

    2015-12-01

    Full Text Available Achondroplasia (ACH is the most common form of hereditary dwarfism and presents with multiple musculoskeletal anomalies but is not normally associated with premature hip arthritis. Developmental dysplasia of the hip (DDH is a spectrum of disease resulting in shallow acetabular depth and a propensity for chronic femoral subluxation or dislocation; it is among the most common causes of premature arthritis. This case report describes the diagnosis of symptomatic DDH in a patient with ACH and highlights difficulties of primary total hip arthroplasty (THA as a treatment option. Intraoperative radiographic imaging is advised to ensure proper prosthesis placement. Femoral osteotomy may aid visualization, reduction, and avoidance of soft tissue injury. Concomitant ACH and DDH is a challenging problem that can be successfully treated with modified THA.

  9. Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip.

    Science.gov (United States)

    Zhang, Yuan Z; Chen, Bin; Lu, Sheng; Yang, Yong; Zhao, Jian M; Liu, Rui; Li, Yan B; Pei, Guo X

    2011-12-01

    The considerable variation in anatomical abnormalities of hip joints associated with different types of developmental dysplasia of hip (DDH) makes reconstruction in total hip arthroplasty (THA) difficult. It is desirable to create patient-specific designs for THA procedures. In the cases of adult single DDH, an accuracy-improved method has been developed for acetabular cup prosthesis implantation of hip arthroplasty. From October 2007 to November 2008, 22 patients with single DDH (according to the Crowe standard, all dysplasia hips were classified as type I) were scanned with spiral CT pre-operatively. These patients scheduled for THA were randomly assigned to undergo either conventional THA (control group, n = 11) or navigation template implantation (NT group, n = 11). In the NT group, three-dimensional (3D) CT pelvis image data were transferred to a computer workstation and 3D models of the hip were reconstructed using the Mimics software. The 3D models were then processed by the Imageware software. In brief, a template that best fitted the location and shape of the acetabular cup was 'reversely' built from the 3D model, the rotation centre of the pathological hip determined by mirroring that of the healthy site, and a guiding hole in the template was then designed. The navigational templates were manufactured using a rapid prototyping machine. These navigation templates guide acetabular component placement. Based on the predetermined abduction angle 45° and anteversion angle 18°, after 1 year follow-up, the NT group showed significantly smaller differences (1.6° ± 0.4°, 1.9° ± 1.1°) from the predetermined angles than those in the control group (5.8° ± 2.9°, 3.9° ± 2.5°) (P < 0.05). The template designs facilitated accurate placement of acetabular components in dysplasia of acetabulum. The hip's center of rotation in DDH could be established using computer-aided design, which provides a useful method for the accurate

  10. [Dislocated fracture of the lesser trochanter with malrotation of the stem after robot assisted implantation of a cementless hip prosthesis: a casuistic report].

    Science.gov (United States)

    Prymka, M; Hassenpflug, J

    2003-08-01

    This paper presents the case of a 63 year old female with a severe coxarthrosis. She got a robot assited implantation of a cementless hip prosthesis (Osteolock, Stryker-Howmedica, Mühlheim). As operation robot the CASPAR-System (Orto-Maquet, Rastatt) was used. Initially, the clinical progress of the patient was fine. She was nearly painfree within 14 days and showed an acceptable range of motion in the operated joint (flexion/ extension 90 degrees /05 degrees /00 degrees ). She was mobilized with crutches and 15 kg weight bearing at the operated leg. 3 weeks postoperative the patient complaint about increasing pain without trauma or intensification of the weight bearing. X-rays showed not only a dislocated fracture of the lesser trochanter, but also a sinking combined with a malrotation of the stem. A revision operation was necessary,where we implanted a cemented stem. Now clinical progress was completely satisfying.

  11. Design of a technique for the radiotherapy treatment of patients of prostate with bilateral prosthetic hip; Diseno de una tecnica para el tratamiento radioterapico de pacientes de prostata con protesis bilateral de cadera

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, C.; Perez-Alija, J.; Olivares, S.; Loscos, S.; Pedro, A.

    2013-07-01

    The design of the plan of treatment of patients who have to undergo radical radiotherapy of prostate and that incorporate some sort of hip prosthesis is usually complex. the case of a patient's prostatic bed with bilateral hip prosthesis to assess radical radiotherapy to the 70Gy in bed. The objective of this paper is to present the chosen technique designed for this treatment. (Author)

  12. The relationship of hospital charges and volume to surgical site infection after total hip replacement.

    Science.gov (United States)

    Boas, Rebecca; Ensor, Kelsey; Qian, Edward; Hutzler, Lorraine; Slover, James; Bosco, Joseph

    2015-05-01

    The purpose of this study was to analyze the effect of hospital volume and charges on the rate of surgical site infections for total hip replacements (THRs) in New York State (NYS). In NYS, higher volume hospitals have higher charges after THR. The study team analyzed 93,620 hip replacements performed in NYS between 2008 and 2011. Hospital charges increased significantly from $43,713 in 2008 to $50,652 in 2011 (P<.01). Compared with lower volume hospitals, patients who underwent THR at the highest volume hospitals had significantly lower surgical site infection rates (P=.003) and higher total hospital charges (P<.0001). The study team found that in the highest volume hospitals, preventing one surgical site infection was associated with $1.6 million dollars in increased charges. © 2014 by the American College of Medical Quality.

  13. Percutaneous Revision of a Testicular Prosthesis is Safe, Cost-effective, and Provides Good Patient Satisfaction

    Directory of Open Access Journals (Sweden)

    Eugene B. Cone

    2015-09-01

    Full Text Available Office-based percutaneous revision of a testicular prosthesis has never been reported. A patient received a testicular prosthesis but was dissatisfied with the firmness of the implant. In an office setting, the prosthesis was inflated with additional fluid via a percutaneous approach. Evaluated outcomes included patient satisfaction, prosthesis size, recovery time, and cost savings. The patient was satisfied, with no infection, leak, or complication after more than 1 year of follow-up, at significantly less cost than revision surgery. Percutaneous adjustment of testicular prosthesis fill-volume can be safe, inexpensive, and result in good patient satisfaction.

  14. A prosthesis-specific multi-link segment model of lower-limb amputee sprinting.

    Science.gov (United States)

    Rigney, Stacey M; Simmons, Anne; Kark, Lauren

    2016-10-03

    Lower-limb amputees commonly utilize non-articulating energy storage and return (ESAR) prostheses for high impact activities such as sprinting. Despite these prostheses lacking an articulating ankle joint, amputee gait analysis conventionally features a two-link segment model of the prosthetic foot. This paper investigated the effects of the selected link segment model׳s marker-set and geometry on a unilateral amputee sprinter׳s calculated lower-limb kinematics, kinetics and energetics. A total of five lower-limb models of the Ottobock ® 1E90 Sprinter were developed, including two conventional shank-foot models that each used a different version of the Plug-in-Gait (PiG) marker-set to test the effect of prosthesis ankle marker location. Two Hybrid prosthesis-specific models were then developed, also using the PiG marker-sets, with the anatomical shank and foot replaced by prosthesis-specific geometry separated into two segments. Finally, a Multi-link segment (MLS) model was developed, consisting of six segments for the prosthesis as defined by a custom marker-set. All full-body musculoskeletal models were tested using four trials of experimental marker trajectories within OpenSim 3.2 (Stanford, California, USA) to find the affected and unaffected hip, knee and ankle kinematics, kinetics and energetics. The geometry of the selected lower-limb prosthesis model was found to significantly affect all variables on the affected leg (p prosthesis-specific spatial, inertial and elastic properties from full-body models significantly affects the calculated amputee gait characteristics, and we therefore recommend the implementation of a MLS model. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. A Hip Implant Energy Harvester

    Science.gov (United States)

    Pancharoen, K.; Zhu, D.; Beeby, S. P.

    2014-11-01

    This paper presents a kinetic energy harvester designed to be embedded in a hip implant which aims to operate at a low frequency associated with body motion of patients. The prototype is designed based on the constrained volume available in a hip prosthesis and the challenge is to harvest energy from low frequency movements (< 1 Hz) which is an average frequency during free walking of a patient. The concept of magnetic-force-driven energy harvesting is applied to this prototype considering the hip movements during routine activities of patients. The magnetic field within the harvester was simulated using COMSOL. The simulated resonant frequency was around 30 Hz and the voltage induced in a coil was predicted to be 47.8 mV. A prototype of the energy harvester was fabricated and tested. A maximum open circuit voltage of 39.43 mV was obtained and the resonant frequency of 28 Hz was observed. Moreover, the power output of 0.96 μW was achieved with an optimum resistive load of 250Ω.

  16. A Hip Implant Energy Harvester

    International Nuclear Information System (INIS)

    Pancharoen, K; Zhu, D; Beeby, S P

    2014-01-01

    This paper presents a kinetic energy harvester designed to be embedded in a hip implant which aims to operate at a low frequency associated with body motion of patients. The prototype is designed based on the constrained volume available in a hip prosthesis and the challenge is to harvest energy from low frequency movements (< 1 Hz) which is an average frequency during free walking of a patient. The concept of magnetic-force-driven energy harvesting is applied to this prototype considering the hip movements during routine activities of patients. The magnetic field within the harvester was simulated using COMSOL. The simulated resonant frequency was around 30 Hz and the voltage induced in a coil was predicted to be 47.8 mV. A prototype of the energy harvester was fabricated and tested. A maximum open circuit voltage of 39.43 mV was obtained and the resonant frequency of 28 Hz was observed. Moreover, the power output of 0.96 μW was achieved with an optimum resistive load of 250Ω

  17. Prosthetic rehabilitation of large mid-facial defect with magnet-retained silicone prosthesis

    Directory of Open Access Journals (Sweden)

    Kirti Jajoo Shrivastava

    2015-01-01

    Full Text Available Rehabilitation of maxillofacial defect patients is a challenging task. The most common prosthetic treatment problem with such patients is, getting adequate retention, stability, and support. In cases of large maxillofacial defect, movement of the prosthesis is inevitable. The primary objectives in rehabilitating the maxillofacial defect patients are to restore the function of mastication, deglutition, speech, and to achieve normal orofacial appearance. This clinical report describes maxillofacial prosthetic rehabilitation of large midfacial defect including orbit along with its contents, zygoma and soft tissues including half of the nose, cheeks, upper lip of left side, accompanying postsurgical microstomia and orofacial communication, which resulted from severe fungal infection mucormycosis. The defect in this case was restored with magnet retained two piece maxillofacial prosthesis having hollow acrylic resin framework and an overlying silicone facial prosthesis. The retention of prosthesis was further enhanced with the use of spectacles. This type of combination prosthesis enhanced the cosmesis and functional acceptability of prosthesis.

  18. Periprosthetic hip joint infection with Aspergillus terreus: A clinical case and a review of the literature

    Directory of Open Access Journals (Sweden)

    Rachel Bartash

    2017-12-01

    Full Text Available Fungal periprosthetic joint infections due to Aspergillus species are rare but are associated with significant cost and morbidity. We present a case of Asperigillus terreus prosthetic joint infection of the hip. The patient was successfully treated with a prolonged course of systemic antifungals along with surgical management. Keywords: Fungal prosthetic joint infection, Aspergillus terreus

  19. Stability of the Giliberty bipolar hip: report of three cases.

    Science.gov (United States)

    Langan, P; Weiss, C A

    1978-01-01

    The Giliberty Bipolar Hip Prosthesis consists of an unbonded acetabular cup which snap-fits over the head of the femoral prosthesis. Because of the free movement permitted at the cup-pelvic junction as well as at the snap-fit interface, there has been a great deal of concern over the potential for dislocation. Three patients in whom this unit was implanted sustained significant skeletal trauma subsequent to surgery. None of them dislocated. In each case the prosthetic head was known to be in a relatively vertical orientation with respect to the transverse axis of the pelvis prior to the injury. In 2 of the 3 cases radiographically identifiable movement of the cup was present before and after the injury. These observations suggest that the persistently mobile, vertically positioned unbonded cup remain stable despite the stress of significant trauma. It is probable that the potential for cup movement, even where on the X-ray it appears to have stopped, acts as a safety valve in absorbing force that might otherwise dislocate the hip or cause fractures of the femur or the pelvis.

  20. MR imaging of 22 Charnley-Mueller total hip prostheses

    International Nuclear Information System (INIS)

    Lemmens, J.A.M.; Ruijs, J.H.J.

    1986-01-01

    To find out whether MR imaging is contraindicated in patients with metallic implants or can be a routine diagnostic procedure, MR investigations in 18 patients with 22 Charnley-Mueller total hip prostheses were performed on a 0.5 T Gyroscan S 5, Philips. No adverse reactions during or post MR investigation were encountered. The imaging of the soft tissue was superior to CT and showed less distortion. The diagnosis of loosening, by detection of demarcation lines at the interfaces was at its best in the distal part of the femoral stem prosthesis and was poor in the acetabular component and in the upper part of the stem prosthesis due to artifacts. (orig.) [de

  1. Poor survival of ABG I hip prosthesis in younger patients

    Czech Academy of Sciences Publication Activity Database

    Gallo, J.; Langová, K.; Havránek, Vítězslav; Čechová, I.

    2008-01-01

    Roč. 152, č. 1 (2008), s. 152-163 ISSN 1213-8118 Institutional research plan: CEZ:AV0Z10100522 Keywords : total hip arthroplasty * ABG I * survival analysis * hydroxyapatie coating * osteolysis Subject RIV: BH - Optics, Masers, Lasers

  2. 99Tcm-MDP imaging for the diagnosis of joint infection after total hip arthroplasty

    International Nuclear Information System (INIS)

    Li Yuan; Wang Qian; Yue Minggang

    2013-01-01

    Objective: To investigate the value of 99 Tc m -MDP imaging for the differential diagnosis between infection and aseptic loosening after total hip arthroplasty. Methods: During February 2008 to August 2011, 74 patients (32 males, 42 females, average age (64.3±11.2) years) with hip pain after arthroplasty underwent 3-phase (blood flow, blood pool and bone phases) 99 Tc m -MDP imaging. All patients had measurements of serum C reactive protein (CRP) and erythrocyte sedimentation rate (ESR). Joint infection was defined as either increased peri-prosthetic soft tissue activity during perfusion and blood pool phases or increased peri-prosthetic bone activity during uptake phase, or positive in all 3 phases. Aseptic loosening was defined as having negative 99 Tc m -MDP in all 3 phases. Clinical diagnosis was chosen as the gold standard. The blood flow-pool imaging was compared with the serum examinations. χ 2 test was used for statistical analysis. Results: There were 74 symptomatic joints in 74 patients, including 24 joint infections and 50 aseptic loosening. For the detection of peri-prosthetic infection, combined perfusion-blood-pool phase was more accurate than bone uptake phase (90.5% (67/74) vs 55.4% (41/74); χ 2 =23.159, P<0.001), with the sensitivity of 91.7% (22/24) vs 70.8% (17/24) and specificity of 90.0% (45/50) vs 48.0% (24/50), respectively. The blood flow-pool imaging was also more accurate than CRP (73.0% (54/74); χ 2 =7.656, P<0.05) and ESR (71.6% (53/74); χ 2 =8.633, P<0.05), respectively. Conclusion: 99 Tc m -MDP perfusion/blood flow-pool imaging is an accurate modality for differentiating peri-prosthetic infection from aseptic loosening in patients with hip pain after arthroplasty. (authors)

  3. Method and ranking of DSA of the hip in detecting loosening of endoprostheses

    International Nuclear Information System (INIS)

    Fink, B.K.; Fink, U.; Hansen, M.; Kirsch, C.M.; Pfahler, M.

    1991-01-01

    Digital subtraction arthrography (DSAr) of the operated hip is presented and compared to nuclide bone scan and plain radiograph. Surgical proof was obtained in 47 patients. In the evaluation DSAr proved to be superior to nuclide bone scan and plain radiograph. DSAr had the best predictive value in the diagnosis of loosening of a prosthesis. In contrast to conventional arthrography there is a better differentiation between the contrast medium, the prosthesis, the acryle cement and the bone by using DSAr. In addition DSAr presents the advantage of postprocessing, especially pixelshift. (orig.) [de

  4. Cementless One-Stage Revision in Chronic Periprosthetic Hip Joint Infection. Ninety-One Percent Infection Free Survival in 56 Patients at Minimum 2-Year Follow-Up

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Solgaard, Søren

    2018-01-01

    was re-revision performed due to infection and was evaluated by competing risk analysis, with death and aseptic revision as competing events. All-cause mortality was evaluated by Kaplan-Meier survival analysis. Oxford Hip Score (OHS) was used as disease-specific patient-reported outcome measure. RESULTS......BACKGROUND: Cementless 1-stage revision in chronic periprosthetic hip joint infections is limited evaluated. The purpose of this study was to evaluate a specific treatment protocol in this patient group. METHODS: The study was performed as a multicenter, proof-of-concept, observational study...

  5. Bursitis of the Hip

    Science.gov (United States)

    ... difficile (C. diff.) InfectionHerpes Home Diseases and Conditions Bursitis of the Hip Condition Bursitis of the Hip Share Print Table of Contents1. ... Prevention5. Treatment6. Everyday Life7. Questions8. Resources What is bursitis of the hip? Bursitis is the painful swelling ...

  6. A Case of Acute Prosthesis Migration after Femoral Head Replacement due to Osteomalacia by FGF23-Induced Tumor

    Directory of Open Access Journals (Sweden)

    Shinya Hayashi

    2012-01-01

    Full Text Available Fibroblast growth factor 23 (FGF23 was recently identified as an important factor involved in the development of hypophosphatemic rickets and osteomalacia. We experienced a rare case of acute prosthesis migration after hemihip arthroplasty due to FGF23-induced tumor. The patient underwent femoral head replacement because of femoral neck fracture, but prosthesis migration was occurred at 1 week after operation. The patient took various examinations, and FGF23-induced tumor was found in his right wrist. The tumor was resected, and he underwent total hip arthroplasty 8 month later. Finally, he was able to obtain free gait without pain.

  7. Carbon-carbon composites for orthopedic prosthesis and implants. CRADA final report

    Energy Technology Data Exchange (ETDEWEB)

    Burchell, T D; Klett, J W; Strizak, J P [Oak Ridge National Lab., TN (United States); Baker, C [FMI, Biddeford, ME (United States)

    1998-01-21

    The prosthetic implant market is extensive. For example, because of arthritic degeneration of hip and knee cartilage and osteoporotic fractures of the hip, over 200,000 total joint replacements (TJRs) are performed in the United States each year. Current TJR devices are typically metallic (stainless steel, cobalt, or titanium alloy) and are fixed in the bone with polymethylacrylate (PMMA) cement. Carbon-carbon composite materials offer several distinct advantages over metals for TJR prosthesis. Their mechanical properties can be tailored to match more closely the mechanical properties of human bone, and the composite may have up to 25% porosity, the size and distribution of which may be controlled through processing. The porous nature of carbon-carbon composites will allow for the ingrowth of bone, achieving biological fixation, and eliminating the need for PMMA cement fixation.

  8. Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

    Science.gov (United States)

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko

    2016-01-01

    A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668

  9. Failed vascularized proximal fibular epiphyseal transfer for hip reconstruction following infection in children.

    Science.gov (United States)

    Debarge, Romain; Chotel, Franck; Gazarian, Aram; Viola, Jérémy; Berard, Jérôme

    2009-08-01

    Treatment of the sequellae of hip infection with epiphyseal destruction in children has had limited success to date. The aim of this study was to report mid-term results after hip epiphyseal reconstruction using a proximal vascularized fibular graft in three children presenting with massive epiphyseal destruction of the proximal femur following infection. Three children suffered from hip articular destruction type IVB according to the Choi classification after neonatal septic arthritis. The mean age at reconstruction was 4.3 years (range 3-6 years). The Hunka et al. criteria were used to evaluate the functional results, and the clinical evaluation was based on the Musculo-Skeletal Tumor Society (MSTS) score. Growth and fusion of the graft and hip morphology were evaluated on simple X-rays and by magnetic resonance imaging (MRI). A ratio between cephalic diameter and inter-acetabular gap was defined on the MRI scan as the "acetabular filling index". No intraoperative complication was reported. With a mean follow-up of 4.8 years (3-6 years), the MSTS score was 22.7/30 (range 20-26), while the average lower limb length discrepancy was 3 cm. Patient 1 required a secondary derotation osteotomy of the femur because of abnormal external rotation and a bad result due to the unexplained occurrence of a painful and stiff hip joint. A secondary distal transfer of the greater trochanter was performed in patient 2, and good results based on Hunka et al.'s criteria were achieved. The X-rays of patients 1 and 2 showed signs of bone growth and a major remodeling process; the MRI filling indices were 83 and 67%, respectively. Patient 3 developed an early slipped capital (fibular) epiphysis 1 month postoperatively, which was treated by percutaneous pinning; this early complication led to a bad result with full resorption of the graft. In contrast to its success in upper limb reconstruction, in this series of three patients with hip articular destruction, articular reconstruction

  10. The role of synovial fluid analysis in the detection of periprosthetic hip and knee infections: a systematic review and meta-analysis.

    Science.gov (United States)

    De Fine, Marcello; Giavaresi, Gianluca; Fini, Milena; Illuminati, Andrea; Terrando, Silvio; Pignatti, Giovanni

    2018-05-01

    This study tried to ascertain (1) the accuracy of synovial fluid white blood cell count and polymorphonucleate percentage in the diagnosis of periprosthetic hip and knee infections, (2) which test yielded superior test performance, and (3) the influence on diagnostic accuracy of study characteristics such as patient number, study design, study level, anatomic site, and threshold value. A systematic search was conducted including papers assessing more effective cutoffs for synovial fluid tests, having comparative design, evaluating an exclusive cohort of hip or knee prostheses, including a clear definition of infected cases, and reporting sufficient data for the calculation of true-positive, false-positive, false-negative, and true-negative. A total of 375 articles were collected and, given the inclusion criteria, ten manuscripts were included. These studies assessed 1155 hip prostheses (276 infected cases) and 1235 knee prostheses (401 infected cases). The specificity of synovial fluid white blood cell count was significantly increased by using the threshold value ≥ 3000 cell/μL (p = 0.006); the sensitivity of polymorphonucleate percentage was significantly higher in detecting knee infections (p = 0.034). Both tests had a high specificity and sensitivity in detecting periprosthetic joint infections, and no clear superiority of one over the other existed. Furthermore, cutoff and anatomic site significantly influenced synovial fluid white blood cell count and polymorphonucleate percentage, respectively. Synovial fluid analysis is adequate in differentiating patients with periprosthetic hip and knee infections. Our data confirms international guidelines suggesting the use of 3000 cell/μL as cutoff threshold for synovial fluid white blood cell count. Since an anatomic site effect has been demonstrated, the goal of future studies will be to identify different cutoffs for hip and knee prostheses.

  11. Gait rehabilitation for a patient with an osseointegrated prosthesis following transfemoral amputation.

    Science.gov (United States)

    Leijendekkers, Ruud A; van Hinte, Gerben; Nijhuis-van der Sanden, Maria Wg; Staal, J Bart

    2017-02-01

    In patients with a transfemoral amputation socket-related problems are associated with reduced prosthetic use, activity, and quality of life. Furthermore, gait asymmetries are present that may explain secondary complaints. Bone-anchored prostheses (BAPs) may help these patients. Two types of BAP are available, screw and press-fit implants. Rehabilitation following surgery for a press-fit BAP is poorly described. To describe a rehabilitation program designed to minimize compensation strategies and increase activity using a case-report of an active, 70-year-old man with a traumatic transfemoral amputation who had used a socket prosthesis for 52 years and received a press-fit BAP [Endo-Exo Femoral Prosthesis - EEFP]. A 13-week physiotherapy program. Outcomes were assessed before surgery, at the end of rehabilitation, and six-month and one-year follow-ups. After rehabilitation gait had improved, the patient had more arm movement, more pelvic shift, less hip rotation during swing phase on the prosthetic side, and absence of vaulting on the sound side. Isometric hip abductor strength was 15% higher on the sound side and 16% higher on the prosthetic side, and walking distance increased from 200 m to 1500 m. At the six-month follow-up, the patient had lower back complications and reduced hip abductor strength and walking distance. At one-year follow-up, walking distance had recovered to 1000 m and gait pattern had improved again, with yielding and absence of terminal impact on the prosthetic side. The described rehabilitation program may be an effective method of improving gait in patients with an EEFP even after long-term socket usage.

  12. [Treatment of periprosthetic femoral fractures after total hip arthroplasty with specially constructed retrograde hollow nails].

    Science.gov (United States)

    Szalay, G; Meyer, C; Mika, J; Schnettler, R; Thormann, U

    2014-12-01

    Treatment of periprosthetic fractures by implantation of a specially constructed, retrograde hollow nail which fits over the tip of the prosthesis and becomes locked on it. Periprosthetic femoral fractures with firmly anchored prosthesis shaft after total hip arthroplasty of types B1 and C according to the Vancouver classification. Loosened prosthesis (type B2/B3) and trochanteric fractures (type A). Broken or damaged prosthesis, florid inflammation and soft tissue injuries in the operation field, contracted knee joint, advanced deformation in the knee joint and distal femur, enclosed prosthesis and general contraindications. In a supine position the periprosthetic fracture is exposed via a lateral access. For cemented prostheses the cement is removed around the tip of the prosthesis (at least 2-3 cm) and medullary cavity. Arthrotomy with flexion of the knee joint and marking of the nail entry point. Drill the medullary cavity, retrograde introduction of the nail, visually fit the nail over the tip of the prosthesis and lock the nail with the prosthesis. If necessary use additional spongiosaplasty or also placement of additional cerclages depending on fracture type and size of the defect zone. Lock the nail distally. Use intraoperative radiological imaging to control correct positioning and length of the nail. Close the wound layer by layer with placement of suction drainage devices and dressing. Partial loading for 6 weeks with a subsequent pain-adapted loading gradient until full loading is possible. If selective partial loading is not possible, a decision must be made in individual cases as to whether the intraoperative findings allow immediate full loading. From 2004 to 2011 a total of 25 periprosthetic femoral fractures in 25 patients were treated in 2 locations using specially constructed slotted hollow nails. Within the framework of a retrospective study 20 of these patients (16 female and 4 male; average age 77.2 [72-84] years) were clinically and

  13. Radiolabelled leucocyte scintigraphy versus conventional radiological imaging for the management of late, low-grade vascular prosthesis infections

    Energy Technology Data Exchange (ETDEWEB)

    Erba, P.A. [University of Pisa, and University Hospital of Pisa, Regional Center of Nuclear Medicine, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy); University of Pisa, Regional Center of Nuclear Medicine, Pisa (Italy); Leo, G. [ASL Lecce, U.O. Gestione Rapporti Convenzionali, U.O. Chirurgia Generale, Lecce, Pisa (Italy); University of Pisa, and University Hospital of Pisa, Division of Vascular Surgery, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy); Sollini, M. [Az. Osp. S.Maria Nuova - IRCCS Reggio Emilia, Nuclear Medicine Unit, Department of Oncology and Advanced Technology, Reggio Emilia (Italy); Tascini, C.; Menichetti, F. [University Hospital of Pisa, Division of Infectious Diseases, Pisa (Italy); Boni, R.; Lazzeri, E.; Mariani, G. [University of Pisa, and University Hospital of Pisa, Regional Center of Nuclear Medicine, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy); Berchiolli, R.N.; Ferrari, M. [University of Pisa, and University Hospital of Pisa, Division of Vascular Surgery, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy)

    2014-02-15

    In this study we evaluated the diagnostic performance of {sup 99m}Tc-HMPAO-leucocyte ({sup 99m}Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods. All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months. {sup 99m}Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37 % of patients (sensitivity and specificity 100 %, versus 85.1 % and 62.5 % for stand-alone SPECT). Sensitivity and specificity were 34 % and 75 % for US, 48.9 % and 83.3 % for CT, and 68.1 % and 62.5 % for the FitzGerald classification. Perioperative mortality was 5.5 %, mid-term mortality 12 %, and long-term mortality 27 %. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61 % versus 63 %, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3 % versus 45.5 %). {sup 99m}Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI

  14. Radiolabelled leucocyte scintigraphy versus conventional radiological imaging for the management of late, low-grade vascular prosthesis infections.

    Science.gov (United States)

    Erba, P A; Leo, G; Sollini, M; Tascini, C; Boni, R; Berchiolli, R N; Menichetti, F; Ferrari, M; Lazzeri, E; Mariani, G

    2014-02-01

    In this study we evaluated the diagnostic performance of (99m)Tc-HMPAO-leucocyte ((99m)Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods. All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months. (99m)Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37% of patients (sensitivity and specificity 100 %, versus 85.1% and 62.5% for stand-alone SPECT). Sensitivity and specificity were 34% and 75% for US, 48.9% and 83.3% for CT, and 68.1% and 62.5% for the FitzGerald classification. Perioperative mortality was 5.5%, mid-term mortality 12%, and long-term mortality 27%. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61% versus 63%, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3% versus 45.5%). (99m)Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI with inconclusive

  15. Radiolabelled leucocyte scintigraphy versus conventional radiological imaging for the management of late, low-grade vascular prosthesis infections

    International Nuclear Information System (INIS)

    Erba, P.A.; Leo, G.; Sollini, M.; Tascini, C.; Menichetti, F.; Boni, R.; Lazzeri, E.; Mariani, G.; Berchiolli, R.N.; Ferrari, M.

    2014-01-01

    In this study we evaluated the diagnostic performance of 99m Tc-HMPAO-leucocyte ( 99m Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods. All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months. 99m Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37 % of patients (sensitivity and specificity 100 %, versus 85.1 % and 62.5 % for stand-alone SPECT). Sensitivity and specificity were 34 % and 75 % for US, 48.9 % and 83.3 % for CT, and 68.1 % and 62.5 % for the FitzGerald classification. Perioperative mortality was 5.5 %, mid-term mortality 12 %, and long-term mortality 27 %. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61 % versus 63 %, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3 % versus 45.5 %). 99m Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI with inconclusive

  16. Results of endoprosthetic hip joint replacement with the aluminum ceramic-metal composite prosthesis "Lindenhof".

    Science.gov (United States)

    Stock, D; Diezemann, E D; Gottstein, J

    1980-01-01

    The first clinical results of the Lindenhof ceramic-metal composite prosthesis implanted in our hospital in Freiburg are presented. We observed that same favorable early results as the conventional prostheses in a correct position. The implants are incorporated into the bone within 8-12 weeks. The radiographic films show the adaptation of the supporting bone around the ceramic socket. We explain the failures due to our initial lack of technical experience and/or anatomical deformation of the pelvic bone. complications caused by the post-operative treatment during the 12 weeks following surgery did not occur. The combination of a cemented metal femoral component with a ceramic head seems to be a reasonable compromise to use the favorable physical and biochemical properties of the bioceramic material as long as there is no satisfactory solution for a stable cementless fixation of the femoral stem in to the bone. The advantages of the Lindenhof prosthesis predominate the disadvantages: expensive instruments and a post-operative treatment of several months.

  17. Two-stage revision of infected hip arthroplasty using a shortened post-operative course of antibiotics.

    LENUS (Irish Health Repository)

    McKenna, Paul B

    2009-04-01

    We present a series of 30 consecutive patients with 31 infected total hip arthroplasties treated by a single surgeon over a 4-year period in whom a shortened post-operative course of antimicrobial chemotherapy was used.

  18. What are the risk factors for post-operative infection after hip hemiarthroplasty? Systematic review of literature.

    Science.gov (United States)

    Noailles, Thibaut; Brulefert, Kévin; Chalopin, Antoine; Longis, Pierre Marie; Gouin, François

    2016-09-01

    Femoral neck fractures are frequent in the elderly population and lead to high morbidity and mortality. Hemiarthroplasty is an established surgical procedure for displaced intracapsular femoral neck fractures. Post-operative infection is frequent and is potentially devastating for the patient and the healthcare services. The goal of this study was to identify the risk factors of infection after hemiarthroplasty and help adapt our surgical practice. A systematic review of the literature was performed in July 2015 by two authors using the MedLine, PubMed and Cochrane databases. We used the MeSH keywords "hip hemiarthroplasty" AND "infection" to identify risk factors and methods of prevention for surgical site infection after hemiarthroplasty. Following the search, two authors independently performed the first stage based on titles and abstracts. Thirty-seven articles were selected. Review and analysis of the references was performed to find other articles of interest. Thirteen articles were selected to analyse. According to literature, the surgical site infection (SSI) rate after hip hemiarthroplasty (HHA) is between 1.7 and 7.3 %. Pre-operative comorbidities (obesity, liver disease, advanced age), operative conditions (junior surgeon, uncemented stems, time of surgery) and post-operative management (length of hospitalisation, haematoma, prolonged wound drainage and two urinary catheterisations) were identified as risk factors of surgical site infection. Authors describe conditions to decrease the incidence of these complications and underline the importance of "a specialised hip team" that provides fast care and helps decrease the duration of hospitalisation. Careful patient management for hemiarthroplasty is vital and may decrease the incidence of surgical site infection, which is associated with high morbidity and high procedure cost. Our review suggests that there are specific correctable risk factors for SSIs after HHA. Being able to identify these risk factors

  19. Intermittent negative pressure wound therapy with instillation for the treatment of persistent periprosthetic hip infections: a report of two cases

    Directory of Open Access Journals (Sweden)

    Söylemez MS

    2016-02-01

    Full Text Available Mehmet Salih Söylemez,1 Korhan Özkan,2 Bülent Kılıç,3 Samet Erinç41Department of Orthopaedics and Traumatology, Bingöl State Hospital, Bingöl, 2Department of Orthopaedics and Traumatology, Faculty of Medicine, Medeniyet University, Istanbul, 3Department of Orthopaedics and Traumatology, Orthopaedic Surgery Clinic, Istanbul Gelişim University, Tekirdağ, 4Department of Orthopaedics and Traumatology, Istanbul Medeniyet University, Göztepe Training and Research Hospital, Istanbul, TurkeyAbstract: Intermittent negative pressure wound therapy with instillation (NPWTi is starting to be used successfully to treat early periprosthetic infections of endoprostheses. However, few articles have reported the outcome of treatment with intermittent NPWTi for late persistent periprosthetic infections of the hip. In this study, we report two cases who underwent several rounds of radical wound debridement for the treatment of a late persistent periprosthetic infection of the hip. Intermittent NPWTi was used in both cases. Patients were treated successfully and there was no recurrence after 3 and 1 years of follow-up, respectively.Keywords: negative pressure, vacuum-assisted, periprosthetic infection, hip

  20. Rationale for one stage exchange of infected hip replacement using uncemented implants and antibiotic impregnated bone graft.

    Science.gov (United States)

    Winkler, Heinz

    2009-09-04

    Infection of a total hip replacement (THR) is considered a devastating complication, necessitating its complete removal and thorough debridement of the site. It is undoubted that one stage exchange, if successful, would provide the best benefit both for the patient and the society. Still the fear of re-infection dominates the surgeons decisions and in the majority of cases directs them to multiple stage protocols. However, there is no scientifically based argument for that practice. Successful eradication of infection with two stage procedures is reported to average 80% to 98%. On the other hand a literature review of Jackson and Schmalzried (CORR 2000) summarizing the results of 1,299 infected hip replacements treated with direct exchange (almost exclusively using antibiotic loaded cement), reports of 1,077 (83%) having been successful. The comparable results suggest, that the major factor for a successful outcome with traditional approaches may be found in the quality of surgical debridement and dead space management. Failures in all protocols seem to be caused by small fragments of bacterial colonies remaining after debridement, whereas neither systemic antibiotics nor antibiotic loaded bone cement (PMMA) have been able to improve the situation significantly. Reasons for failure may be found in the limited sensitivity of traditional bacterial culturing and reduced antibiotic susceptibility of involved pathogens, especially considering biofilm formation. Whenever a new prosthesis is implanted into a previously infected site the surgeon must be aware of increased risk of failure, both in single or two stage revisions. Eventual removal therefore should be easy with low risk of additional damage to the bony substance. On the other hand it should also have potential of a good long term result in case of success. Cemented revisions generally show inferior long term results compared to uncemented techniques; the addition of antibiotics to cement reduces its

  1. Self and partner satisfaction rates after 3 part inflatable penile prosthesis implantation.

    Science.gov (United States)

    Simsek, Abdulmuttalip; Kucuktopcu, Onur; Ozgor, Faruk; Ozkuvanci, Unsal; Baykal, Murat; Sarilar, Omer; Gurbuz, Zafer Gokhan

    2014-09-30

    To evaluate and present satisfaction rates of our patients and their partners after 3 part inflatable penile prosthesis implantation. We searched our hospital electronic data for patients who underwent inflatable penile prosthesis implantation between January 2008 and July 2013. Computer and archived file data were used to get information and reach the patients. We made telephone calls to patients and asked questionnaires about self and partner satisfaction rates. 36 patients underwent prosthesis implantation during the 5 year period. We were able to reach by telephone call 18 of them. The mean age of 18 patients was 55.7 ± 9.4 years and mean body mass index was 24.6 ± 2.1 kg/m2. The etiology was diabetes mellitus on 14 (77.8%) and radical pelvic surgery on 4 (22.2%) patients. 14 of 18 patients had penile Doppler ultrasound test. Doppler ultrasound demonstrated venous insufficiency in 8 and arterial insufficiency in 6 patients. Mean time from implantation to study was 20.8 ± 13.9 months. Out of 18 patients 2 had prosthesis removal operation because of infection in one patient and perforation in the other. Satisfaction rate was 88.9%, and recommendation rate was 94.4%. Causes of dissatisfaction were pain in one patient and insufficient rigidity plus shortening of the penis in the other one. Partner satisfaction rate was 94.4%. Penile Prosthesis Implantation (PPI) is the gold standard treatment of erectile dysfunction (ED) irresponsive to medical treatment. Infection and mechanical failure rates are going to be less according to the improvements in synthetic materials and coverings of the prosthesis, so patient and partner satisfaction rates will be higher.

  2. Clostridium perfringens infection complicating periprosthetic fracture fixation about the hip: successful treatment with early aggressive debridement.

    LENUS (Irish Health Repository)

    Baker, Joseph F

    2012-07-13

    Periprosthetic fracture and infection are both challenges following hip arthroplasty. We report the case of an 87 year old female who underwent open reduction and internal fixation of a periprosthetic femoral fracture. Her post-operative course was complicated by infection with Clostridium perfringens. Early aggressive antibiotic treatment and surgical debridement were successful, and allowed retention of the original components.

  3. Differential bacterial load on components of total knee prosthesis in patients with prosthetic joint infection.

    Science.gov (United States)

    Holinka, Johannes; Pilz, Magdalena; Hirschl, Alexander M; Graninger, Wolfgang; Windhager, Reinhard; Presterl, Elisabeth

    2012-10-01

    The purpose of our study was to evaluate and quantify the bacterial adherence on different components of total knee prosthesis with the sonication culture method. Explanted components of all patients with presumptive prosthetic or implant infection were treated by sonication separately in sterile containers to dislodge the adherent bacteria from the surfaces and cultured. The bacterial load of the different knee components (femur, tibia, PE-inlay and patella) was evaluated by counting of colony-forming units (CFU) dislodged from the components surfaces using the sonication culture method. Overall, 27 patients had positive sonication cultures of explanted total knee prostheses. Microorganisms were detected from 88 of 100 explanted components. Twenty femoral components were culture positive and 7 negative, 23 tibial components as well as 23 polyethylene (PE) platforms had positive microorganism detection from the surface. Staphylococcus epidermidis adhered to the highest number of components whereas Staphylococcus aureus yielded the highest load of CFU in the sonication cultures. Although not significant, PE-inlays and tibial components were most often affected. The highest CFU count was detected in polyethylene components. The sonication culture method is a reliable method to detect bacteria from the components. Additionally, the results demonstrate that bacterial adherence is not affecting a single component of knee prosthesis only. Thus, in septic revision surgery partial prosthetic exchange or exchange of single polyethylene components alone may be not sufficient.

  4. Pre-operative urinary tract infection: is it a risk factor for early surgical site infection with hip fracture surgery? A retrospective analysis.

    Science.gov (United States)

    Yassa, Rafik Rd; Khalfaoui, Mahdi Y; Veravalli, Karunakar; Evans, D Alun

    2017-03-01

    The aims of the current study were to determine whether pre-operative urinary tract infections in patients presenting acutely with neck of femur fractures resulted in a delay to surgery and whether such patients were at increased risk of developing post-operative surgical site infections. A retrospective review of all patients presenting with a neck of femur fracture, at a single centre over a one-year period. The hospital hip fracture database was used as the main source of data. UK University Teaching Hospital. All patients ( n  = 460) presenting across a single year study period with a confirmed hip fracture. The presence of pre-operative urinary tract infection, the timing of surgical intervention, the occurrence of post-operative surgical site infection and the pathogens identified. A total of 367 patients were operated upon within 24 hours of admission. Urinary infections were the least common cause of delay. A total of 99 patients (21.5%) had pre-operative urinary tract infection. Post-operatively, a total of 57 (12.4%) patients developed a surgical site infection. Among the latter, 31 (54.4%) did not have a pre-operative urinary infection, 23 (40.4%) patients had a pre-operative urinary tract infection, 2 had chronic leg ulcers and one patient had a pre-operative chest infection. Statistically, there was a strong relationship between pre-operative urinary tract infection and the development of post-operative surgical site infection ( p -value: 0.0005). The results of our study indicate that pre-operative urinary tract infection has a high prevalence amongst those presenting with neck of femur fractures, and this is a risk factor for the later development of post-operative surgical site infection.

  5. Validation of the diagnosis 'prosthetic joint infection' in the Danish Hip Arthroplasty Register

    DEFF Research Database (Denmark)

    Gundtoft, P H; Pedersen, Alma Becic; Schønheyder, H C

    2016-01-01

    and followed them until first-time revision, death, emigration or until 31 December 2012. Revision for PJI, as registered in the DHR, was validated against a benchmark which included information from microbiology databases, prescription registers, clinical biochemistry registers and clinical records. We......AIMS: The purpose of this study was to validate the diagnosis of periprosthetic joint infection (PJI) in the Danish Hip Arthroplasty Register (DHR). PATIENTS AND METHODS: We identified a cohort of patients from the DHR who had undergone primary total hip arthroplasty (THA) since 1 January 2005...... the validity of the diagnosis of PJI and should enable future register-based studies. Cite this article: Bone Joint J 2016;98-B:320-5....

  6. Clinical experience with an alloplastic stoma prosthesis (Biocarbon) for urinary conduits and cutaneous ureterostomy.

    Science.gov (United States)

    Månsson, W; Harzmann, R

    1988-01-01

    An alloplastic stoma prosthesis, Biocarbon, composed of 99.9% pure carbon in vitreous form, was used in six patients with conduit urinary diversion and in seven with cutaneous ureterostomy. The patients were thereafter observed for 2-86 months. Complications were subcutaneous infection, urinary fistula and ureteral stenosis, which necessitated removal of the prosthesis in most cases. The permanent stoma, without need for adhesive collecting device, was appreciated by the patients. Problems relating to biocompatibility remain to be solved before the place of the stoma prosthesis in urinary diversion can be determined.

  7. In-situ electrochemical study of interaction of tribology and corrosion in artificial hip prosthesis simulators.

    Science.gov (United States)

    Yan, Yu; Dowson, Duncan; Neville, Anne

    2013-02-01

    The second generation Metal-on-Metal (MoM) hip replacements have been considered as an alternative to commonly used Polyethylene-on-Metal (PoM) joint prostheses due to polyethylene wear debris induced osteolysis. However, the role of corrosion and the biofilm formed under tribological contact are still not fully understood. Enhanced metal ion concentrations have been reported widely from hair, blood and urine samples of patients who received metal hip replacements and in isolated cases when abnormally high levels have caused adverse local tissue reactions. An understanding of the origin of metal ions is really important in order to design alloys for reduced ion release. Reciprocating pin-on-plate wear tester is a standard instrument to assess the interaction of corrosion and wear. However, more realistic hip simulator can provide a better understanding of tribocorrosion process for hip implants. It is very important to instrument the conventional hip simulator to enable electrochemical measurements. In this study, simple reciprocating pin-on-plate wear tests and hip simulator tests were compared. It was found that metal ions originated from two sources: (a) a depassivation of the contacting surfaces due to tribology (rubbing) and (b) corrosion of nano-sized wear particles generated from the contacting surfaces. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Differential contributions of specimen types, culturing, and 16S rRNA sequencing in diagnosis of prosthetic joint infections

    DEFF Research Database (Denmark)

    Larsen, Lone Heimann; Khalid, Vesal; Xu, Yijuan

    2018-01-01

    Prosthetic joint failure is mainly caused by infection, aseptic failure (AF), and mechanical problems. Infection detection has been improved with modified culture methods and molecular diagnostics. However, comparisons between modified and conventional microbiology methods are difficult due...... to variations in specimen sampling. In this prospective, multidisciplinary study of hip or knee prosthetic failures, we assessed the contributions of different specimen types, extended culture incubations, and 16S rRNA sequencing for diagnosing prosthetic joint infections (PJI). Project specimens included joint...... fluid (JF), bone biopsy specimens (BB), soft-tissue biopsy specimens (STB), and swabs (SW) from the prosthesis, collected in situ, and sonication fluid collected from prosthetic components (PC). Specimens were cultured for 6 (conventional) or 14 days, and 16S rRNA sequencing was performed at study...

  9. Risk of pneumonia and urinary tract infection within the first week after total hip arthroplasty and the impact on survival

    Directory of Open Access Journals (Sweden)

    Glassou EN

    2017-01-01

    Full Text Available Eva N Glassou,1,2 Torben B Hansen,1,3 Alma B Pedersen2 1University Clinic of Hand, Hip and Knee Surgery, Department of Orthopedic Surgery, Regional Hospital West Jutland, Aarhus University, 2Department of Clinical Epidemiology, Aarhus University Hospital, 3The Lundbeck Foundation Centre for Fast-track Hip and Knee Replacement, Aarhus University, Aarhus, Denmark Background: Pneumonia and urinary tract infections (UTIs increase morbidity and mortality. There is little epidemiological evidence from large population-based studies on risk factors for these infections and subsequent mortality in total hip arthroplasty (THA patients.Aim: To examine the risk factors of postoperative pneumonia and UTI after THA and their impact on survival.Patients and methods: We used the Danish Hip Arthroplasty Register to identify THAs due to osteoarthritis registered from 2000 to 2013. We collected data about comorbidities, mortality and infections in relation to primary hospitalization and potential predictive variables from administrative databases. Regression models were used to estimate associations between potential risk factors and infection, and subsequently, between infection and mortality.Results: In total 84,812 THAs were included. The cumulative incidence of pneumonia and UTI within 7 days of the primary procedure were 0.21 (95% confidence interval [CI]: 0.18–0.25 and 0.29 (95% CI: 0.26–0.33, respectively. Patient-related risk factors for infection were being 80 years or older, gender and a comorbidity burden at time of surgery. The hazard ratio (HR of dying within 90 days of the primary THA was 10.67 (95% CI: 5.79–19.57 compared to patients without pneumonia. For patients with UTIs, the HR was 1.64 (95% CI: 0.41–6.59 compared to those without a UTI.Conclusion: Pneumonia was associated with an increased short-term risk of dying, despite adjustment for coexisting comorbidity and other potential confounders. Age, gender and comorbidity were the most

  10. Finite element analysis of 2-Station hip himulator

    Science.gov (United States)

    Fazli, M. I. M.; Yahya, A.; Shahrom, A.; Nawawi, S. W.; Zainudin, M. R.; Nazarudin, M. S.

    2017-10-01

    This paper presented the analysis of materials and design architecture of 2-station hip simulator. Hip simulator is a machine used to conduct the joint and wear test of hip prosthetic. In earlier work, the hip simulator was modified and some improvement were made by using SolidWorks software. The simulator consists of 3DOF which controlled by separate stepper motor and a static load that set up by manual method in each station. In this work, finite element analysis (FEA) of hip simulator was implemented to analyse the structure of the design and selected materials used for simulator component. The analysis is completed based on two categories which are safety factor and stress tests. Both design drawing and FEA was done using SolidWorks software. The study of the two categories is performed by applying the peak load up to 4000N on the main frame that is embedded with metal-on-metal hip prosthesis. From FEA, the value of safety factor and degree of stress formation are successfully obtained. All the components exceed the value of 2 for safety factor analysis while the degree of stress formation shows higher value compare to the yield strength of the material. With this results, it provides information regarding part of simulator which are susceptible to destruct. Besides, the results could be used for design improvement and certify the stability of the hip simulator in real application.

  11. Self and partner satisfaction rates after 3 part inflatable penile prosthesis implantation

    Directory of Open Access Journals (Sweden)

    Abdulmuttalip Simsek

    2014-09-01

    Full Text Available Objective: To evaluate and present satisfaction rates of our patients and their partners after 3 part inflatable penile prosthesis implantation. Materials and methods: We searched our hospital electronic data for patients who underwent inflatable penile prosthesis implantation between January 2008 and July 2013. Computer and archived file data were used to get information and reach the patients. We made telephone calls to patients and asked questionnaires about self and partner satisfaction rates. Results: 36 patients underwent prosthesis implantation during the 5 year period. We were able to reach by telephone call 18 of them. The mean age of 18 patients was 55.7 ± 9.4 years and mean body mass index was 24.6 ± 2.1 kg/m2. The etiology was diabetes mellitus on 14 (77.8% and radical pelvic surgery on 4 (22.2% patients. 14 of 18 patients had penile Doppler ultrasound test. Doppler ultrasound demonstrated venous insufficiency in 8 and arterial insufficiency in 6 patients. Mean time from implantation to study was 20.8 ± 13.9 months. Out of 18 patients 2 had prosthesis removal operation because of infection in one patient and perforation in the other. Satisfaction rate was 88.9%, and recommendation rate was 94.4%. Causes of dissatisfaction were pain in one patient and insufficient rigidity plus shortening of the penis in the other one. Partner satisfaction rate was 94.4%. Conclusion: Penile Prosthesis Implantation (PPI is the gold standard treatment of erectile dysfunction (ED irresponsive to medical treatment. Infection and mechanical failure rates are going to be less according to the improvements in synthetic materials and coverings of the prosthesis, so patient and partner satisfaction rates will be higher.

  12. Plannig strategy for radiotherapic treatment oa patients with prosthetic hip. Solution of intensity

    International Nuclear Information System (INIS)

    Puertolas Hernandez, J. R.; Iriondo Igerabide, U.; Lozano Flores, F. J.; Pino Leon, C.; Larretxea Etxarri, R.

    2013-01-01

    The intensity modulated radiation therapy (IMRT) can offer better plans, defining the prosthesis as critical structure that limit the dose. In our case, in the last year we have made five planning hip replacement cases, and one case with two prostheses (bilateral). We are introducing the strategy we use to carry out these planning. (Author)

  13. Wear of alumina on alumina total hip prosthesis - effect of lubricant on hip simulator test

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, M.; Amino, H. [Kyocera Corp., Fushimi, Kyoto (Japan). Bioceram Div.; Oonishi, H. [Dept. of Orthopaedic Surgery, Artificial Joint Sect. and Biomat. Res. Lab., Osaka Minami National Hospital, Osaka (Japan); Clarke, I.C.; Good, V. [Dept. of Orthopaedic Surgery, Loma Linda Univ. Medical Center, CA (United States)

    2001-07-01

    The complex wear-friction-lubrication behavior of alumina on alumina combination in total hip prostheses (THP) was investigated using a hip joint simulator. The objectives of this study were to evaluate the effect of the ball/cup clearance and of the lubricant conditions. Alumina bearings were categorized in three diametrical clearances, 20-30, 60-70 and 90-100 micrometer, three each and wear tests were carried out with 90% bovine serum. There was no significant difference between three groups. Volumetric wear in the run-in phase for all tested nine ceramic liners averaged 0.27mm{sup 3}/million cycles and in the steady-state phase averaged 0.0042mm{sup 3}/million cycles. In addition to the 90% serum, 27% serum and saline were used as the lubricant for evaluate the effect of serum concentration on alumina on alumina wear couples. The wear test results showed that in all tested conditions the wear trends of alumina BEARING were bi-phasic and wear volume could be affected by the serum concentration. Both ''Run-in'' and ''Steady-state'' wear rates in 90% bovine serum were three times higher than those in saline. (orig.)

  14. The Utility of Digital Linear Tomosynthesis Imaging of Total Hip Joint Arthroplasty with Suspicion of Loosening: A Prospective Study in 40 Patients

    Science.gov (United States)

    Göthlin, Jan H.

    2013-01-01

    Aim. The clinical utility of digital linear tomosynthesis in musculoskeletal applications has been validated in only a few reports. Technical performance and utility in hip prosthesis imaging have been discussed in technical reports, but no clinical evaluation has been reported. The purpose of the current study was to assess the added clinical utility of digital linear tomosynthesis compared to radiography in loosening of total hip joint arthroplasty. Materials and Methods. In a prospective study, radiography and digital tomosynthesis were performed in 40 consecutive patients with total hip arthroplasty referred for suspect prosthesis loosening. Tomosynthesis images were compared to anterior-posterior (AP) and cross-table lateral radiographs regarding demarcation and extent of demineralization and osteolysis. Further noted were skeletal fractures, cement fractures, fragmentation, and artifacts interfering with the diagnosis. Results. Tomosynthesis was superior to radiography with sharper delineation of demineralization and osteolysis in the AP projection. A limitation was the inability to generate lateral tomosynthesis images, with inferior assessment of the area anterior and posterior to the acetabular cup compared to cross-table radiographs. Artifacts interfering with diagnosis were found in one hip. Conclusion. Tomosynthesis improved evaluation of total hip arthroplasty in the AP projection but was limited by the lack of lateral projections. PMID:24078921

  15. The Utility of Digital Linear Tomosynthesis Imaging of Total Hip Joint Arthroplasty with Suspicion of Loosening: A Prospective Study in 40 Patients

    Directory of Open Access Journals (Sweden)

    Jan H. Göthlin

    2013-01-01

    Full Text Available Aim. The clinical utility of digital linear tomosynthesis in musculoskeletal applications has been validated in only a few reports. Technical performance and utility in hip prosthesis imaging have been discussed in technical reports, but no clinical evaluation has been reported. The purpose of the current study was to assess the added clinical utility of digital linear tomosynthesis compared to radiography in loosening of total hip joint arthroplasty. Materials and Methods. In a prospective study, radiography and digital tomosynthesis were performed in 40 consecutive patients with total hip arthroplasty referred for suspect prosthesis loosening. Tomosynthesis images were compared to anterior-posterior (AP and cross-table lateral radiographs regarding demarcation and extent of demineralization and osteolysis. Further noted were skeletal fractures, cement fractures, fragmentation, and artifacts interfering with the diagnosis. Results. Tomosynthesis was superior to radiography with sharper delineation of demineralization and osteolysis in the AP projection. A limitation was the inability to generate lateral tomosynthesis images, with inferior assessment of the area anterior and posterior to the acetabular cup compared to cross-table radiographs. Artifacts interfering with diagnosis were found in one hip. Conclusion. Tomosynthesis improved evaluation of total hip arthroplasty in the AP projection but was limited by the lack of lateral projections.

  16. A clinical, radiological and biomechanical study of the TARA hip prosthesis

    NARCIS (Netherlands)

    Waal Malefijt, de M.C.; Huiskes, H.W.J.

    1993-01-01

    We reviewed 60 patients with 72 TARA (total articular replacement arthroplasty) resurfacing hip prostheses. To analyse the behaviour of the femoral component a radiographic study was done and a two-dimensional finite element model was constructed. The stem of the femoral component plays a role in

  17. Efficacy of Antibiotic Suppressive Therapy in Patients with a Prosthetic Joint Infection.

    Science.gov (United States)

    Wouthuyzen-Bakker, Marjan; Nijman, Jasperina M; Kampinga, Greetje A; van Assen, Sander; Jutte, Paul C

    2017-01-01

    Introduction: For chronic prosthetic joint infections (PJI), complete removal of the infected prosthesis is necessary in order to cure the infection. Unfortunately, a subgroup of patients is not able to undergo a revision surgery due to high surgical risk. Alternatively, these patients can be treated with antibiotic suppressive therapy (AST) to suppress the infection. Aim: To evaluate the efficacy and tolerability of AST. Methods: We retrospectively collected data (period 2009-2015) from patients with a PJI (of hip, knee or shoulder) who were treated with AST at the University Medical Center Groningen, the Netherlands. AST was defined as antibiotic treatment for PJI that was started after the usual 3 months of antibiotic treatment. The time of follow-up was defined from the time point AST was started. Treatment was considered as failed, when the patient still experienced joint pain, when surgical intervention (debridement, removal, arthrodesis or amputation) was needed to control the infection and/or when death occurred due to the infection. Results: We included 21 patients with a median age of 67 years (range 21 - 88) and with a median follow-up of 21 months (range 3 - 81). Coagulase negative staphylococci (CNS) (n=6), S. aureus (n=6) and polymicrobial flora (n=4) were the most frequently found causative pathogens. Most patients with CNS and S. aureus were treated with minocycline (67%) and clindamycin (83%) as AST, respectively. Overall, treatment was successful in 67% of patients. Failure was due to persistent joint pain (n=1), surgical intervention because of an uncontrolled infection (n=3), and death due the infection (n=3). We observed a treatment success of 90% in patients with a 'standard' prosthesis (n=11), compared to only 50% in patients with a tumor-prosthesis (n=10). Also, treatment was successful in 83% of patients with a CNS as causative microorganism for the infection, compared to 50% in patients with a S. aureus . Patients who failed on AST had a

  18. The acetabulum: A prospective study of three-phase bone and indium white blood cell scintigraphy following porous-coated hip arthroplasty

    International Nuclear Information System (INIS)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Anderson, J.H.; Callaghan, J.J.

    1990-01-01

    Although few studies address the use of three-phase bone scanning (TPBS) and indium-111-labeled white blood cell scintigraphy ( 111 In-WBC) in hip arthroplasty utilizing a porous-coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen with the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous-coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and 111I n-WBC at approximately 7 days, and 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the acetabulum. All 25 prostheses (144 of 144 scans) demonstrated increased uptake on the bone-phase images. Although this activity decreased with time, 76% had persistent uptake at 24 mo. Twenty-three of 25 prostheses (126 of 140 scans) showed increased uptake on 111 In-WBC scintigraphy, invariably decreasing with time, but with 37% having significant uptake at 24 mo. Scintigraphic patterns in the uncomplicated porous-coated hip arthroplasty patient appear to differ from patterns described in cemented prostheses

  19. Sensitivity and specificity of simultaneously acquired (dual channel) radiogallium and Tc-99m-HDP in painful hip and knee prosthetic joints

    International Nuclear Information System (INIS)

    Skarzynski, J.J.; Sziklas, J.J.; Rosenberg, R.J.; Rich, D.A.; Spencer, R.P.

    1985-01-01

    Differentiation of prosthetic loosening from infection, by use of sequential bone and radiogallium imaging, has been discussed in the literature. The authors investigated simultaneous (2 channel) imaging of Ga-67 and Tc-99m-HDP in multiviews, in order to assess the parameter of Tc-99m-Ga-67 incongruity. Acquisition of data was carried out 2 days after 5 mCi of Ga-67 citrate IV and 2 hours after 8 mCi of Tc-99m-HDP. Dual data channels were used to insure perfect superimposition of the images and to reduce total imaging time. Normalized bone images were taken, then subtracted from those of Ga-67, by means of progressive weighting factors. A total of 68 studies were carried out on 43 patients. Exams involved both knee and hip prostheses, in population with 63% of the patients over age 60 years. Time from placement of the prosthesis to the dual radionuclide exam was within 2 years in 48% and within 5 years in 78%. Sensitivity was 0.88 and specificity 0.89. Using information on the follow-up dual channel studies, 40/43 cases were correctly identified (93%). Dual channel radionuclide imaging offers a readily available and accurate means of differentiating infection from loosening of hip or knee prostheses

  20. Dual X-ray absortiometry(DXA) in the detection of loosening in the total hip replacement arthroplasty: preliminary study

    International Nuclear Information System (INIS)

    Yoon, Hye Kyung; Kang, Heung Sik; Han, Man Chung; Kim, Hee Joong; Kim, Young Min

    1994-01-01

    Algorithms to get cross-sectional bone density pattern(transverse histogram) to predict the loosening of hip prosthesis using DXA(Dual X-ray Absorptiometry) have been developed. We performed this study to analyze the correlation between radiologic findings and densitometric pattern of the THRA(Total Hip Replacement Arthroplasty) patients. Thirty-six hips of 32 THRA patients were evaluated. The duration between THRA and DXA was from 1 year 7 months to 15 years. On transverse histogram, the periprosthetic bone density patterns were classified as 3 types; type I , rigid fixation in 17, type II definite loosening in 8, and type III, partial loosening in 11 cases. Surgical findings, plain X-ray findings and transverse histogram using DXA were correlated. Among 14 cases performing revision for acetabular prosthesis loosening, 5 cases revealed loosening of femoral stems while 9 cases revealed rigid fixation of femoral stems. Sensitivity was 100% for either plain X-ray or DXA. Specificity was 88%, 77% for plain X-ray and DXA respectively. This preliminary study reveals that periprosthetic bone density pattern on transverse histogram on DXA may be useful in the evaluation of the loosening. However, further study will be needed for clinical application

  1. [Study of friction and loosening in hip endoprostheses].

    Science.gov (United States)

    Dovzak Bajs, Ivana; Cvjetko, Ivan; Car, Dolores; Kokić, Visnja

    2002-01-01

    Like any other operative procedure, the implantation of hip prosthesis is associated with certain complications, which diminishes the value and purpose of such a procedure. One of the complications in artificial hip implantation is loosening of the alloplastic material. Therefore, the aim of this study was to examine the effect of lubrication on the torsional moment and its role in the loosening of the femoral component, using an experimental mechanical model. The following hypothesis was tested: the magnitude of torsional loading in the "bone-endoprosthesis-bone cement system" is similar to any other known loading. The testing device was constructed with the possibility of simulation of positions similar to original performances in the implanted hip prosthesis. It refers primarily to the possibilities of achieving definite forces and velocities. The intention was to point quantitatively to the role of friction moment between the acetabular and femoral endoprosthesis part. Trials were conducted by combining 7 types of loading and 4 kinds of lubrication: dry, water, plasma, and light oil. The testing joint (Ring's prosthesis) was connected through tensometric measuring shaft upon the working forepart oscillating mechanism. Graded by the changeable static loading by means of the pendulum and via lever mechanism the testing joint was loaded by force from 610 to 7137 N. As the cause of friction resistance in the moving joint, torque deformaties of the measuring shaft occurred. The testing joint enabled oscillating movement using a four-part mechanism. In this way, it was possible to define not only the maximum values of the frictional moment (or the coefficient of friction) during one movement cycle but also to examine its relation to the kind of lubrication. Change in the measuring torsional moment were computer recorded. Before each trial, the gauging of the complete outfit was performed. Thereafter, cleaning of the frictional surfaces of the whole outfit was done

  2. Short Operative Duration and Surgical Site Infection Risk in Hip and Knee Arthroplasty Procedures.

    Science.gov (United States)

    Dicks, Kristen V; Baker, Arthur W; Durkin, Michael J; Anderson, Deverick J; Moehring, Rebekah W; Chen, Luke F; Sexton, Daniel J; Weber, David J; Lewis, Sarah S

    2015-12-01

    To determine the association (1) between shorter operative duration and surgical site infection (SSI) and (2) between surgeon median operative duration and SSI risk among first-time hip and knee arthroplasties. Retrospective cohort study A total of 43 community hospitals located in the southeastern United States. Adults who developed SSIs according to National Healthcare Safety Network criteria within 365 days of first-time knee or hip arthroplasties performed between January 1, 2008 and December 31, 2012. Log-binomial regression models estimated the association (1) between operative duration and SSI outcome and (2) between surgeon median operative duration and SSI outcome. Hip and knee arthroplasties were evaluated in separate models. Each model was adjusted for American Society of Anesthesiology score and patient age. A total of 25,531 hip arthroplasties and 42,187 knee arthroplasties were included in the study. The risk of SSI in knee arthroplasties with an operative duration shorter than the 25th percentile was 0.40 times the risk of SSI in knee arthroplasties with an operative duration between the 25th and 75th percentile (risk ratio [RR], 0.40; 95% confidence interval [CI], 0.38-0.56; Poperative duration did not demonstrate significant association with SSI for hip arthroplasties (RR, 1.04; 95% CI, 0.79-1.37; P=.36). Knee arthroplasty surgeons with shorter median operative durations had a lower risk of SSI than surgeons with typical median operative durations (RR, 0.52; 95% CI, 0.43-0.64; Poperative durations were not associated with a higher SSI risk for knee or hip arthroplasty procedures in our analysis.

  3. One- and two-stage surgical revision of peri-prosthetic joint infection of the hip: a pooled individual participant data analysis of 44 cohort studies.

    Science.gov (United States)

    Kunutsor, Setor K; Whitehouse, Michael R; Blom, Ashley W; Board, Tim; Kay, Peter; Wroblewski, B Mike; Zeller, Valérie; Chen, Szu-Yuan; Hsieh, Pang-Hsin; Masri, Bassam A; Herman, Amir; Jenny, Jean-Yves; Schwarzkopf, Ran; Whittaker, John-Paul; Burston, Ben; Huang, Ronald; Restrepo, Camilo; Parvizi, Javad; Rudelli, Sergio; Honda, Emerson; Uip, David E; Bori, Guillem; Muñoz-Mahamud, Ernesto; Darley, Elizabeth; Ribera, Alba; Cañas, Elena; Cabo, Javier; Cordero-Ampuero, José; Redó, Maria Luisa Sorlí; Strange, Simon; Lenguerrand, Erik; Gooberman-Hill, Rachael; Webb, Jason; MacGowan, Alasdair; Dieppe, Paul; Wilson, Matthew; Beswick, Andrew D

    2018-04-05

    One-stage and two-stage revision strategies are the two main options for treating established chronic peri-prosthetic joint infection (PJI) of the hip; however, there is uncertainty regarding which is the best treatment option. We aimed to compare the risk of re-infection between the two revision strategies using pooled individual participant data (IPD). Observational cohort studies with PJI of the hip treated exclusively by one- or two-stage revision and reporting re-infection outcomes were retrieved by searching MEDLINE, EMBASE, Web of Science, The Cochrane Library, and the WHO International Clinical Trials Registry Platform; as well as email contact with investigators. We analysed IPD of 1856 participants with PJI of the hip from 44 cohorts across four continents. The primary outcome was re-infection (recurrence of infection by the same organism(s) and/or re-infection with a new organism(s)). Hazard ratios (HRs) for re-infection were calculated using Cox proportional frailty hazards models. After a median follow-up of 3.7 years, 222 re-infections were recorded. Re-infection rates per 1000 person-years of follow-up were 16.8 (95% CI 13.6-20.7) and 32.3 (95% CI 27.3-38.3) for one-stage and two-stage strategies respectively. The age- and sex-adjusted HR of re-infection for two-stage revision was 1.70 (0.58-5.00) when compared with one-stage revision. The association remained consistently absent after further adjustment for potential confounders. The HRs did not vary importantly in clinically relevant subgroups. Analysis of pooled individual patient data suggest that a one-stage revision strategy may be as effective as a two-stage revision strategy in treating PJI of the hip.

  4. Robotic lower limb prosthesis design through simultaneous computer optimizations of human and prosthesis costs

    Science.gov (United States)

    Handford, Matthew L.; Srinivasan, Manoj

    2016-02-01

    Robotic lower limb prostheses can improve the quality of life for amputees. Development of such devices, currently dominated by long prototyping periods, could be sped up by predictive simulations. In contrast to some amputee simulations which track experimentally determined non-amputee walking kinematics, here, we explicitly model the human-prosthesis interaction to produce a prediction of the user’s walking kinematics. We obtain simulations of an amputee using an ankle-foot prosthesis by simultaneously optimizing human movements and prosthesis actuation, minimizing a weighted sum of human metabolic and prosthesis costs. The resulting Pareto optimal solutions predict that increasing prosthesis energy cost, decreasing prosthesis mass, and allowing asymmetric gaits all decrease human metabolic rate for a given speed and alter human kinematics. The metabolic rates increase monotonically with speed. Remarkably, by performing an analogous optimization for a non-amputee human, we predict that an amputee walking with an appropriately optimized robotic prosthesis can have a lower metabolic cost - even lower than assuming that the non-amputee’s ankle torques are cost-free.

  5. Pre-operative urinary tract infection: is it a risk factor for early surgical site infection with hip fracture surgery? A retrospective analysis

    OpenAIRE

    Yassa, Rafik RD; Khalfaoui, Mahdi Y; Veravalli, Karunakar; Evans, D Alun

    2017-01-01

    Objective The aims of the current study were to determine whether pre-operative urinary tract infections in patients presenting acutely with neck of femur fractures resulted in a delay to surgery and whether such patients were at increased risk of developing post-operative surgical site infections. Design A retrospective review of all patients presenting with a neck of femur fracture, at a single centre over a one-year period. The hospital hip fracture database was used as the main source of ...

  6. Prosthetic joint infection-a devastating complication of hemiarthroplasty for hip fracture.

    Science.gov (United States)

    Guren, Ellen; Figved, Wender; Frihagen, Frede; Watne, Leiv Otto; Westberg, Marianne

    2017-08-01

    Background and purpose - Hemiarthroplasty is the most common treatment in elderly patients with displaced femoral neck fracture. Prosthetic joint infection (PJI) is a feared complication. The infection rate varies in the literature, and there are limited descriptive data available. We investigated the characteristics and outcome of PJI following hemiarthroplasty over a 15-year period. Patients and methods - Patients with PJI were identified among 519 patients treated with hemiarthroplasty for a femoral neck fracture at Oslo University Hospital between 1998 and 2012. We used prospectively registered data from previous studies, and recorded additional data from the patients' charts when needed. Results - Of the 519 patients, we identified 37 patients (6%) with early PJI. 20 of these 37 patients became free of infection. Soft tissue debridement and retention of implant was performed in 35 patients, 15 of whom became free of infection with an intact arthroplasty. The 1-year mortality rate was 15/37. We found an association between 1-year mortality and treatment failure (p = 0.001). Staphylococcus aureus and polymicrobial infection were the most common microbiological findings, each accounting for 14 of the 37 infections. Enterococcus spp. was found in 9 infections, 8 of which were polymicrobial. There was an association between polymicrobial infection and treatment failure, and between polymicrobial infection and 1-year mortality. Interpretation - PJI following hemiarthroplasty due to femoral neck fracture is a devastating complication in the elderly. We found a high rate of polymicrobial PJIs frequently including Enterococcus spp, which is different from what is common in PJI after elective total hip arthroplasty.

  7. Total hip arthroplasty survival in femoral head avascular necrosis versus primary hip osteoarthritis: Case-control study with a mean 10-year follow-up after anatomical cementless metal-on-metal 28-mm replacement.

    Science.gov (United States)

    Ancelin, D; Reina, N; Cavaignac, E; Delclaux, S; Chiron, P

    2016-12-01

    Total hip arthroplasty is the most widely used procedure to treat avascular necrosis (AVN) of the femoral head. Few studies have compared the outcomes of THA in femoral head AVN and primary hip osteoarthritis. Therefore we performed a case-control study to compare THA for femoral head AVN vs. primary hip osteoarthritis in terms of: (1) prosthesis survival, (2) complication rates, (3) functional outcomes and radiographic outcomes, (4) and to determine whether specific risk factors for THA failure exist in femoral head AVN. THA survival is similar in femoral head AVN and primary hip osteoarthritis. We compared two prospective cohorts of patients who underwent THA before 65 years of age, one composed of cases with femoral head AVN and the other of controls with primary hip osteoarthritis. In both cohorts, a cementless metal-on-metal prosthesis with a 28-mm cup and an anatomical stem was used. Exclusion criteria were THA with other types of prosthesis, posttraumatic AVN, and secondary osteoarthritis. With α set at 5%, to obtain 80% power, 246 patients were required in all. Prosthesis survival was assessed based on time to major revision (defined as replacement of at least one implant fixed to bone) and time to aseptic loosening. The other evaluation criteria were complications, Postel-Merle d'Aubigné (PMA) score, and the Engh and Agora Radiographic Assessment (ARA) scores for implant osseointegration. The study included 282 patients, 149 with AVN and 133 with osteoarthritis. Mean age was 47.8±10.2 years (range, 18.5-65) and mean follow-up was 11.4±2.8 years (range, 4.5-18.3 years). The 10-year survival rates were similar in the two groups: for major revision, AVN group, 92.5% (95% confidence interval [95% CI], 90.2-94.8) and osteoarthritis group, 95.3% (95% CI, 92.9-97.7); for aseptic loosening, AVN group, 98.6% (95% CI, 97.6-98.6) and osteoarthritis, 99.2% (95% CI, 98.4-100). The AVN group had higher numbers of revision for any reason (19 vs. 6, P=0.018) and

  8. The Efficacy of the Quorum Sensing Inhibitor FS8 and Tigecycline in Preventing Prosthesis Biofilm in an Animal Model of Staphylococcal Infection

    Directory of Open Access Journals (Sweden)

    Andrea Giacometti

    2013-08-01

    Full Text Available We investigated the efficacy of tigecycline and FS8, alone or combined, in preventing prosthesis biofilm in a rat model of staphylococcal vascular graft infection. Graft infections were established in the back subcutaneous tissue of adult male Wistar rats by implantation of Dacron prostheses followed by topical inoculation with 2 x 107 colony-forming units of Staphylococcus aureus, strain Smith diffuse. The study included a control group, a contaminated group that did not receive any antibiotic prophylaxis, and three contaminated groups that received: (i intraperitoneal tigecycline, (ii FS8-soaked graft, and (iii tigecycline plus FS8-soaked graft, respectively. Each group included 15 animals. The infection burden was evaluated by using sonication and quantitative agar culture. Moreover, an in vitro binding-study was performed to quantify the how much FS8 was coated to the surface of the prosthesis. Tigecycline, combined with FS8, against the adherent bacteria showed MICs (2.00 mg/L and MBCs (4.00 mg/L four-fold lower with respect to tigecycline alone in in vitro studies. The rat groups treated with tigecycline showed the lowest bacterial numbers (4.4 x 104 ± 1.2 x 104 CFU/mL. The FS8-treated group showed a good activity and significant differences compared to control group with bacterial numbers of 6.8 x 104 ± 2.0 x 104 CFU/mL. A stronger inhibition of bacterial growth was observed in rats treated with a combined FS8 and tigecycline therapy than in those that were singly treated with bacterial numbers of 101 CFU/mL graft. In conclusion, the ability to affect biofilm formation as well, its property to be an antibiotic enhancer suggests FS8 as alternative or additional agent to use in conjunction with conventional antimicrobial for prevention of staphylococcal biofilm related infection.

  9. COMPARISON OF UNIPOLAR (MOORE’S PROSTHESIS AND BIPOLAR HEMIARTHROPLASTY IN FRACTURE NECK OF FEMUR IN THE ELDERLY- A SHORT-TERM PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Mahendra Bendale

    2016-11-01

    Full Text Available BACKGROUND Femoral neck fractures are common in postmenopausal elderly females as a result of osteoporosis due to trivial trauma or in the young due to high energy trauma. The goal of the surgeon is to return the patient to his/her prefracture functional status. Femoral neck fracture could be impacted and undisplaced or displaced. Femoral neck fractures are also considered “fractures of necessity”, best treated surgically irrespective of displacement. Surgery permits early patient mobilisation and minimises the complications of prolonged recumbence. The bipolar prosthesis has advantage over the unipolar in having two bearings for the movements to occur. This study intends to compare the functional outcome of unipolar Moore’s hemi-replacement and fixed bipolar replacement in elderly patients with fracture neck of femur. In this scenario, the null hypothesis would be that there is no significant difference in the results between the patients treated with Moore’s prosthesis and those treated with bipolar prosthesis. The aim of the study is to compare the results of unipolar and bipolar hemi-arthroplasty for fracture neck of femur in the elderly patients. MATERIALS AND METHODS 30 elderly postmenopausal women with fracture neck femur were included in the study. They were divided into 2 groups and were operated upon by using unipolar and bipolar implants respectively after thorough investigation. The functional outcome was assessed using the Harris Hip Score (HHS. RESULTS Femoral neck fractures belonged to 53.3% with type III fracture and 46.7 had type IV fractures. Fifteen patients had replacement with Austin Moore prosthesis and fifteen patients with bipolar prosthesis. The average HHS at 6 weeks for unipolar and bipolar groups was 65.2 and 66.0, respectively. The average HHS at 12 months for unipolar and bipolar group was 81.0 and 83.6, respectively. 19 (65.5% patients had good HHS at the end of one year. Corrected chi-square value is 2

  10. Radionuclide arthrogram with SPECT/CT for the evaluation of mechanical loosening of hip and knee prostheses

    International Nuclear Information System (INIS)

    Chew, C.G.; Lewis, P.; Middleton, F.; Wijngaard, R. van den; Deshaies, A.

    2010-01-01

    The Objective of this study was to evaluate the value of single photon emission computed tomography (SPECT)/CT in radionuclide arthrogram (RNA) for the assessment of mechanical loosening of hip and knee prostheses. A retrospective audit of 117 RNA SPECT/CTs evaluated by a single reader- 40 hips, (1 hemiarthroplasty) and 77 knees (12 unicompartmental). The detection of any radiotracer within the bone/prosthetic interface was deemed positive for loosening. The operative assessment of 29 hip and 44 knee prosthetic joints was known and used as the gold standard. A subsequent blinded reassessment of the planar images was performed and compared with the SPECT/CT results for 26 of the 29 hip and 42 of the 44 knee prostheses. The respective SPECT/CT versus planar results were as follows: hips- acetabular cup: sensitivity: 73 versus 0%; specificity: 71 versus 100%; positive predictive value: 62% versus indeterminate; negative predictive value: 80% versus 72% (p=0.0044). Hips- femoral component: sensitivity: 78 versus 63%; specificity: 90 versus 94%; positive predictive value: 78 versus 83%; negative predictive value: 90 versus 85% (p=0.2482). Knees- femoral component: sensitivity: 75 versus 17%; specificity 63 versus 97%; positive predictive value: 43 versus 67%; negative predictive value: 87 versus 74% (p=0.0001). Knees- tibial component: sensitivity: 86 versus 63%; specificity: 86 versus 76%; positive predictive value: 55 versus 38%; negative predictive value: 97 versus 90% (p=0.6831). For evaluation of mechanical loosening of the hip prosthesis SPECT/CT was significantly better than planar scanning for the acetabular cup, but not for the femoral stem. For evaluation of the knee prosthesis, a significant improvement was noted using SPECT/CT for the femoral component, and although superior results were also noted for the tibial component, statistical significance was not reached. Taking into account the limitations of this retrospective audit, the value of using RNA SPECT

  11. [Technology of cementless hip endoprosthetics].

    Science.gov (United States)

    Ungethüm, M; Blömer, W

    1987-06-01

    The success achieved with non-cemented hip arthroplasty depends mainly on the stability of the fixation, the quality of the stabilizing bone being just as important as favourable biomechanical conditions. The results of the intensive research and development with respect to the particular features of a non-cemented hip endoprosthesis can be divided into the following basic categories: Biomechanical aspects with special reference to bone related to the design of the prosthesis; material characteristics, such as fatigue strength, tribology, corrosion resistance, and biocompatibility; and development of new materials and coatings to permit direct bonding of implant and bone. With regard to the stem of hip prostheses, the different design parameters of various types are examined to determine their typical design characteristics, such as bearing surface of the collar, geometry of cross section, anatomically adapted shaping, and surface of the implant forming the contact with the bone. The latter can be divided into macroprofiles and macro- and micro-porous coated surfaces. On the other hand, the methods of cementless fixation of acetabular cups can be primarily divided into conical and spherical screw fixation and pegged fixation with additional macroprofiles of porous surfaces. In a separate study of the biomechanical aspects of screwed sockets, the special importance of socket shape and thread geometry are presented with reference to primary stability and long-term fixation of prostheses.

  12. Total-hip arthroplasty: Periprosthetic indium-111-labeled leukocyte activity and complementary technetium-99m-sulfur colloid imaging in suspected infection

    International Nuclear Information System (INIS)

    Palestro, C.J.; Kim, C.K.; Swyer, A.J.; Capozzi, J.D.; Solomon, R.W.; Goldsmith, S.J.

    1990-01-01

    Indium-111-labeled leukocyte images of 92 cemented total-hip arthroplasties were correlated with final diagnoses. Prostheses were divided into four zones: head (including acetabulum), trochanter, shaft, and tip. The presence (or absence) and intensity of activity in each zone was noted, and compared to the corresponding contralateral zone. Though present in all 23 infected arthroplasties, periprosthetic activity was also present in 77% of uninfected arthroplasties, and was greater than the contralateral zone 51% of the time. When analyzed by zone, head zone activity was the best criterion for infection (87% sensitivity, 94% specificity, 92% accuracy). Fifty of the arthroplasties were studied with combined labeled leukocyte/sulfur colloid imaging. Using incongruence of images as the criterion for infection, the sensitivity, specificity, and accuracy of the study were 100%, 97%, and 98%, respectively. While variable periprosthetic activity makes labeled leukocyte imaging alone unreliable for diagnosing hip arthroplasty infection, the addition of sulfur colloid imaging results in a highly accurate diagnostic procedure

  13. The Development of Skull Prosthesis Through Active Contour Model.

    Science.gov (United States)

    Chen, Yi-Wen; Shih, Cheng-Ting; Cheng, Chen-Yang; Lin, Yu-Cheng

    2017-09-09

    Skull defects result in brain infection and inadequate brain protection and pose a general danger to patient health. To avoid these situations and prevent re-injury, a prosthesis must be constructed and grafted onto the deficient region. With the development of rapid customization through additive manufacturing and 3D printing technology, skull prostheses can be fabricated accurately and efficiently prior to cranioplasty. However, an unfitted skull prosthesis made with a metal implant can cause repeated infection, potentially necessitating secondary surgery. This paper presents a method of creating suitably geometric graphics of skull defects to be applied in skull repair through active contour models. These models can be adjusted in each computed tomography slice according to the graphic features, and the curves representing the skull defect can be modeled. The generated graphics can adequately mimic the natural curvature of the complete skull. This method will enable clinical surgeons to rapidly implant customized prostheses, which is of particular importance in emergency surgery. The findings of this research can help surgeons provide patients with skull defects with treatment of the highest quality.

  14. The Angelchik prosthesis

    International Nuclear Information System (INIS)

    Fargnoli, R.; Bozza, A.; Magnoli, A.; Villari, N.; Pernice, L.M.; Andreoli, F.; Lombardi, P.

    1989-01-01

    The Angelchik prosthesis is used in the surgical treatment of gastroesophageal reflux. Operated patients are preliminary examined with imaging techniques, but manometric and acidometric techniques are also used. Although the conventional esophagogram still maintains its diagnostic significance, Computed Tomography (CT) has become the first-choice imaging modality. CT allows the correct evaluation of both the state of the prosthesis and its relationship to the esophagus and gastric fundus. The possible postoperative complications following an incorrect placement of the prosthesis can be accurately diagnosed too. The authors report their experience in the study of 5 patients examined with both conventional radiology and CT

  15. 18F-F.D.G. PET imaging of infection and inflammation: intestinal, prosthesis replacements, fibrosis, sarcoidosis, tuberculosis.

    International Nuclear Information System (INIS)

    Fernandez, A.; Cortes, M.; Caresia, A.P.; Juan, R. de; Vidaller, A.; Mana, J.; Martinez-Yelamos, S.; Gamez, C.

    2008-01-01

    Nuclear medicine plays an important role in the evaluation of infection and inflammation. A variety of diagnostic methods are available for imaging this inflammation and infection, most notably computed tomography, 68 Ga scintigraphy or radionuclide labeled leucocytes. Fluorine 18 fluorodeoxyglucose ( 18 F-F.D.G.) is a readily available radiotracer that offers rapid, exquisitely sensitive high-resolution images by positron emission tomography (PET). Inflammation can be acute or chronic, the former showing predominantly neutrophilic granulocyte infiltrates, whereas in the latter, macrophages predominate. F.D.G. uptake in infection is based on the fact that mononuclear cells and granulocytes use large quantities of glucose by way of the hexose monophosphate shunts. 18 F-F.D.G. PET accurately helps diagnose spinal osteomyelitis, diabetic foot and in inflammatory conditions such as sarcoidosis and tuberculosis.(it appears to be useful for defining the extent of disease and monitoring response to treatment). 18 F-F.D.G. PET can also help localize the source of fever of undetermined origin, thereby guiding additional testing. 18 F-F.D.G. PET may be of limited usefulness in postoperative patients and in patients with a failed joint prosthesis or bowel inflammatory disease. In this review, we will focus on the role of 18 F-F.D.G. PET in the management of patients with inflammation or suspected or confirmed infection

  16. An experimental-numerical method for comparative analysis of joint prosthesis; Un metodo numerico-experimental para el analisis comparativo de protesis articulares

    Energy Technology Data Exchange (ETDEWEB)

    Claramunt, R.; Rincon, E.; Zubizarreta, V.; Ros, A.

    2001-07-01

    The difficulty that exists in the analysis of mechanical stresses in bones is high due to its complex mechanical and morphological characteristics. This complexity makes generalists modelling and conclusions derived from prototype tests very questionable. In this article a relatively simple comparative analysis systematic method that allow us to establish some behaviour differences in different kind of prosthesis is presented. The method, applicable in principle to any joint problem, is based on analysing perturbations produced in natural stress states of a bone after insertion of a joint prosthesis and combines numerical analysis using a 3-D finite element model and experimental studies based on photoelastic coating and electric extensometry. The experimental method is applied to compare two total hip prosthesis cement-free femoral stems of different philosophy. One anatomic of new generation, being of oblique setting over cancellous bone and the other madreporique of trochantero-diaphyseal support over cortical bone. (Author) 4 refs.

  17. bladder injury during infected total hip arthroplasty prosthesis

    African Journals Online (AJOL)

    of Radiology, Antalya Training and Research Hospital, Antalya, Turkey. Correspondence ... The bladder is the most frequently injured organ during pelvic surgery. However ... to the pelvic floor, and this could predispose the bladder to injury.

  18. SU-G-IeP2-03: Comparison of Dose Calculation On MAR (metal Artifact Reduction) and Non-MAR Datasets for Pelvic Patients with Hip Prosthesis and Head and Neck Patients with Dental Filling

    International Nuclear Information System (INIS)

    Huang, V; Kohli, K

    2016-01-01

    Purpose: Metal artifact reduction (MAR) software in computed tomography (CT) was previously evaluated with phantoms demonstrating the algorithm is capable of reducing metal artifacts without affecting the overall image quality. The goal of this study is to determine the dosimetric impact when calculating with CT datasets reconstructed with and without MAR software. Methods: Twelve head and neck cancer patients with dental fillings and four pelvic cancer patients with hip prosthesis were scanned with a GE Optima RT 580 CT scanner. Images were reconstructed with and without the MAR software. 6MV IMRT and VMAT plans were calculated with AAA on the MAR dataset until all constraints met our clinic’s guidelines. Contours from the MAR dataset were copied to the non-MAR dataset. Next, dose calculation on the non-MAR dataset was performed using the same field arrangements and fluence as the MAR plan. Conformality index, D99% and V100% to PTV were compared between MAR and non-MAR plans. Results: Differences between MAR and non-MAR plans were evaluated. For head and neck plans, the largest variations in conformality index, D99% and V100% were −3.8%, −0.9% and −2.1% respectively whereas for pelvic plans, the biggest discrepancies were −32.7%, −0.4% and -33.5% respectively. The dosimetric impact from hip prosthesis is greater because it produces more artifacts compared to dental fillings. Coverage to PTV can increase or decrease depending on the artifacts since dark streaks reduce the HU whereas bright streaks increase the HU. In the majority of the cases, PTV dose in the non-MAR plans is higher than MAR plans. Conclusion: With the presence of metals, MAR algorithm can allow more accurate delineation of targets and OARs. Dose difference between MAR and non-MAR plans depends on the proximity of the organ to the high density material, the streaking artifacts and the beam arrangements of the plan.

  19. SU-G-IeP2-03: Comparison of Dose Calculation On MAR (metal Artifact Reduction) and Non-MAR Datasets for Pelvic Patients with Hip Prosthesis and Head and Neck Patients with Dental Filling

    Energy Technology Data Exchange (ETDEWEB)

    Huang, V; Kohli, K [BC Cancer Agency, Surrey, BC (United Kingdom)

    2016-06-15

    Purpose: Metal artifact reduction (MAR) software in computed tomography (CT) was previously evaluated with phantoms demonstrating the algorithm is capable of reducing metal artifacts without affecting the overall image quality. The goal of this study is to determine the dosimetric impact when calculating with CT datasets reconstructed with and without MAR software. Methods: Twelve head and neck cancer patients with dental fillings and four pelvic cancer patients with hip prosthesis were scanned with a GE Optima RT 580 CT scanner. Images were reconstructed with and without the MAR software. 6MV IMRT and VMAT plans were calculated with AAA on the MAR dataset until all constraints met our clinic’s guidelines. Contours from the MAR dataset were copied to the non-MAR dataset. Next, dose calculation on the non-MAR dataset was performed using the same field arrangements and fluence as the MAR plan. Conformality index, D99% and V100% to PTV were compared between MAR and non-MAR plans. Results: Differences between MAR and non-MAR plans were evaluated. For head and neck plans, the largest variations in conformality index, D99% and V100% were −3.8%, −0.9% and −2.1% respectively whereas for pelvic plans, the biggest discrepancies were −32.7%, −0.4% and -33.5% respectively. The dosimetric impact from hip prosthesis is greater because it produces more artifacts compared to dental fillings. Coverage to PTV can increase or decrease depending on the artifacts since dark streaks reduce the HU whereas bright streaks increase the HU. In the majority of the cases, PTV dose in the non-MAR plans is higher than MAR plans. Conclusion: With the presence of metals, MAR algorithm can allow more accurate delineation of targets and OARs. Dose difference between MAR and non-MAR plans depends on the proximity of the organ to the high density material, the streaking artifacts and the beam arrangements of the plan.

  20. Dual energy X-ray absorptiometry analysis of peri-prosthetic stress shielding in the Birmingham resurfacing hip replacement.

    LENUS (Irish Health Repository)

    Harty, J A

    2012-02-03

    INTRODUCTION: Numerous reports in the literature refer to the femoral neck fracture rate in hip resurfacing. The aim of this study was to determine the bone mineral density and evidence of stress shielding around the femoral component of the Birmingham resurfacing prosthesis. MATERIAL AND METHODS: Twenty-eight patients with primary unilateral osteoarthritis had a Birmingham resurfacing prosthesis. DEXA analysis of the proximal femur and femoral neck was performed and compared with the opposite unaffected side. RESULTS: Total periprosthetic bone mineral density was 0.49% greater than the control, but this did not achieve statistical significance. Although the BMD of the femoral neck was slightly increased on the prosthetic side (1.002 g\\/cm2) as opposed to the control side, this difference did not reach statistical significance. CONCLUSION: The Birmingham resurfacing prosthesis does not appear to reduce femoral neck bone mineral density in comparison to the normal femoral neck bone density. We conclude that femoral neck fractures are unlikely to be due to stress shielding related to the prosthesis.

  1. Chronic infections in hip arthroplasties: comparing risk of reinfection following one-stage and two-stage revision: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Lange J

    2012-03-01

    Full Text Available Jeppe Lange1,2, Anders Troelsen3, Reimar W Thomsen4, Kjeld Søballe1,51Lundbeck Foundation Centre for Fast-Track Hip and Knee Surgery, Aarhus C, 2Center for Planned Surgery, Silkeborg Regional Hospital, Silkeborg, 3Department of Orthopaedics, Hvidovre Hospital, Hvidovre, 4Department of Clinical Epidemiology, Aarhus University Hospital, Aalborg, 5Department of Orthopaedics, Aarhus University Hospital, Aarhus C, DenmarkBackground: Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two-stage revisions for chronic infection in hip arthroplasties.Methods: The review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis. Relevant studies were identified using PubMed and Embase. We assessed studies that included patients with a chronic infection of a hip arthroplasty treated with either one-stage or two-stage revision and with available data on occurrence of reinfections. We performed a meta-analysis estimating absolute risk of reinfection using a random-effects model.Results: We identified 36 studies eligible for inclusion. None were randomized controlled trials or comparative studies. The patients in these studies had received either one-stage revision (n = 375 or two-stage revision (n = 929. Reinfection occurred with an estimated absolute risk of 13.1% (95% confidence interval: 10.0%–17.1% in the one-stage cohort and 10.4% (95% confidence interval: 8.5%–12.7% in the two-stage cohort. The methodological quality of most included studies was considered low, with insufficient data to evaluate confounding factors.Conclusions: Our results may indicate three additional reinfections per 100 reimplanted patients when performing a one-stage versus two-stage revision. However, the

  2. Diagnostics of 'non-acute' vascular prosthesis infection using {sup 18}F-FDG PET/CT: our experience with 96 prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Spacek, M. [First Faculty of Medicine and General Teaching Hospital, Second Clinical Department of Cardiovascular Surgery, Prague (Czech Republic); Na Homolce Hospital, Department of Vascular Surgery, Prague (Czech Republic); Belohlavek, O.; Votrubova, J. [PET Centre, Na Homolce Hospital, Department of Nuclear Medicine, Prague (Czech Republic); Sebesta, P.; Stadler, P. [Na Homolce Hospital, Department of Vascular Surgery, Prague (Czech Republic)

    2009-05-15

    Vascular prosthesis infection (VPI) is a life-threatening complication that occurs in 0.5-5% of prostheses. Low-grade infections in non-acute patients are a diagnostic challenge requiring a new method with good diagnostic accuracy. The aim of this work was to define the accuracy of {sup 18}F-FDG PET/CT in these settings and to identify essential parameters of the evaluation. PET/CT was performed prospectively in 76 consecutive patients with a total of 96 vascular prosthetic grafts in which infection was suspected. PET/CT scans were analysed in terms of the presence and intensity of focal and diffuse FDG uptake, the presence of an anastomotic pseudoaneurysm, the presence of an irregular boundary of infiltration, a combination of these, and the uptake ratio between the graft and blood background. The gold standard was based on operative/histopathological finding or a clinical follow up of >6 months. Among the various assessed parameters only focal FDG uptake and an irregular graft boundary were significant predictors of VPI. Focal intense FDG uptake together with an irregular boundary of the lesion on CT scan predicted VPI with 97% probability, while smooth lesion boundaries and no focal FDG uptake predicted a probability of VPI of less than 5%. Even in lesions with nondiagnostic inhomogeneous focal FDG uptake (18/96) an irregular boundary effectively helped in decision-making with a probability of 28% (smooth) or 77% (irregular) for VPI. PET/CT gave reliable results with an accuracy >95% in 75% of prostheses. PET/CT can identify those prostheses (25% of prosthesis) for which its diagnostic accuracy is diminished to 70-75%. In our series PET/CT was an excellent diagnostic modality for suspected VPI. (orig.)

  3. Dislocation of total hip replacement in patients with fractures of the femoral neck.

    Science.gov (United States)

    Enocson, Anders; Hedbeck, Carl-Johan; Tidermark, Jan; Pettersson, Hans; Ponzer, Sari; Lapidus, Lasse J

    2009-04-01

    Total hip replacement is increasingly used in active, relatively healthy elderly patients with fractures of the femoral neck. Dislocation of the prosthesis is a severe complication, and there is still controversy regarding the optimal surgical approach and its influence on stability. We analyzed factors influencing the stability of the total hip replacement, paying special attention to the surgical approach. We included 713 consecutive hips in a series of 698 patients (573 females) who had undergone a primary total hip replacement (n = 311) for a non-pathological, displaced femoral neck fracture (Garden III or IV) or a secondary total hip replacement (n = 402) due to a fracture-healing complication after a femoral neck fracture. We used Cox regression to evaluate factors associated with prosthetic dislocation after the operation. Age, sex, indication for surgery, the surgeon's experience, femoral head size, and surgical approach were tested as independent factors in the model. The overall dislocation rate was 6%. The anterolateral surgical approach was associated with a lower risk of dislocation than the posterolateral approach with or without posterior repair (2%, 12%, and 14%, respectively (p replacement in patients with femoral neck fractures.

  4. A prospective dual-energy X-ray absorptiometry study of bone remodeling after implantation of the Nanos short-stemmed prosthesis.

    Science.gov (United States)

    Zeh, Alexander; Pankow, Franziska; Röllinhoff, Marc; Delank, Stefan; Wohlrab, David

    2013-04-01

    The aim of this study was to analyze the bone remodeling around the Nanos stem (Smith & Nephew, Marl, Germany) after primary total hip arthroplasty for coxarthrosis. In 25 patients (15 male, 10 female, mean age 59.9 years) with the diagnosis of coxarthrosis, a DEXA scan was performed immediately after surgery, 97 days (SD 6.1 days) and 368 days (SD 6.2 days) after implantation of a Nanos prosthesis. Plain radiographs were analyzed digitally for radiolucent lines, varus-valgus femoral stem alignment, measurement of stem migration and changes in varus-valgus femoral stem alignment. The position of the center of rotation (COR) and the offset were assessed pre- and postoperatively. Harris Hip Score was used to evaluate the clinical outcome. The DEXA scan showed a significant and relevant increase in BMD (Bone Mineral Density) in Gruen-Zone 6 (12%) and a decrease in Zone 1 (15%), 2 (5%) and 7 (12%), which was interpreted as reflecting a distal load transfer in the metaphysis of the femur. There was no clinically relevant migration or tilting of the Nanos stem. Radiolucent lines were noted in 12 cases, mainly at the polished tip area of the prosthesis; this was not regarded as a sign of impaired osseointegration. There was no significant difference between the position of the COR and the pre- and postoperative offset. The absence of stem migration, angulation, or relevant radiolucent lines is seen as evidence for an unimpaired osseointegration of the Nanos stem approximately 12 months after implantation. It is concluded that the Nanos prosthesis can reduce loss of BMD of the proximal femur composed with conventional stems or other short-stemmed implants.

  5. The effect of education of nurses on preventing catheter-associated urinary tract infections in patients who undergo hip fracture surgery.

    Science.gov (United States)

    Seyhan Ak, Ezgi; Özbaş, Ayfer

    2018-03-01

    The aim of the study was to investigate the effect of educating nurses on preventing catheter-associated urinary tract infections in patients who undergo hip fracture surgery. Urinary tract infections after hip fracture surgery are observed at a rate of 12% to 61%, and the most important risk factor associated with urinary tract infection is considered to be the presence of urinary catheters. Nurse education about the use and management of urinary catheters is important to decrease the risk of urinary tract infections. The study was semi-experimental. The study was conducted in an orthopedics and traumatology clinic of a training hospital between January 2014-December 2015. After a power analysis was performed, a total of 60 patients fulfilled the criteria to be included in the study, with n = 30 in the pre-education group and n = 30 in the posteducation group. Nurses who worked in the orthopedics and traumatology clinic of the military hospital were the target population, and 18 nurses who consented to join the study constituted the sample. The "Patient Monitoring Form," "Nurse Information Form" and "Daily Urinary Catheter Assessment Tool" were used as data collection tools. The mean pre-education knowledge score of the nurses was found to be 68.05 ± 10.69, while the mean posteducation score was 95.13 ± 6.27. The mean catheter duration decreased from 11.06 ± 6.34 days-3.83 ± 0.95 days after the education. The catheter-associated urinary tract infection rate decreased by 9.37 per thousand. Educating nurses on preventing catheter-associated urinary tract infections in patients who underwent hip fracture surgery significantly decreased the rate of catheter-associated urinary tract infections and the duration of catheterisation. The systematic and comprehensive education of all healthcare professionals and the development and practice of catheter removal protocols could contribute to the prevention of catheter-associated urinary tract infections.

  6. A novel knee prosthesis model of implant-related osteo- myelitis in rats

    DEFF Research Database (Denmark)

    Søe, Niels H.; Jensen, Nina Vendel; Nürnberg, Birgit Meinecke

    2012-01-01

    There have been numerous reports of animal models of osteomyelitis. Very few of these have been prosthesis models that imitate human conditions. We have developed a new rat model of implant-related osteomyelitis that mimics human osteomyelitis, to investigate the pathology of infection after...

  7. Long-term outcome of acute prosthetic joint infections due to gram-negative bacilli treated with retention of prosthesis.

    Science.gov (United States)

    Jaén, N; Martínez-Pastor, J C; Muñoz-Mahamud, E; García-Ramiro, S; Bosch, J; Mensa, J; Soriano, A

    2012-09-01

    To update the clinical information of the 47 patients with a prosthetic joint infection due to Gram-negative bacilli included in a previous study and to reassess the predictors of failure after a longer follow-up. Using the electronic files of our hospital, all the information regarding readmissions to the hospital, new surgical procedures and the reason for the new surgery (infection, aseptic loosening), and the last visit in the hospital were registered. The medical chart of the 35 patients that were considered in remission in the previous publication was reviewed. In 30 patients no clinical evidence of failure was detected and no additional surgery on the previously infected prosthesis was necessary and they were considered in long-term remission. In 5 cases a late complication was identified. One case had a reinfection due to coagulase-negative staphylococci after 22 months from the open debridement and required a 2-stage revision surgery. The other 4 cases developed an aseptic loosening and it was necessary to perform a 1-stage exchange. Receiving a fluoroquinolone when all the Gram-negatives involved in the infection were susceptible to fluoroquinolones was the only factor associated with remission in the univariate analysis (p=0.002). After a long-term follow-up, our results support the importance of using fluoroquinolones in acute PJI due to Gram-negative bacilli.

  8. Periprosthetic fractures in the resurfaced hip--A case report and review of the literature.

    LENUS (Irish Health Repository)

    Brennan, Stephen A

    2013-02-01

    Traumatic periprosthetic fractures adjacent a hip resurfacing prosthesis are rare. When proximal fractures are encountered the obvious surgical solution is to revise to a large head stemmed femoral component. A previously well functioning implant may however be retained as various non-operative and operative treatment options exist. This paper reports the case history of a traumatic periprosthetic fracture successfully treated with cannulated screw fixation and reviews the current literature.

  9. Three-phase bone scan and indium white blood cell scintigraphy following porous coated hip arthroplasty: A prospective study of the prosthetic tip

    International Nuclear Information System (INIS)

    Oswald, S.G.; Van Nostrand, D.; Savory, C.G.; Callaghan, J.J.

    1989-01-01

    Although few reports address the use of three-phase bone scanning (TPBS) and 111 In-labeled white blood cell (In-WBC) scintigraphy in hip arthroplasty utilizing a porous coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen in the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and In-WBC at approximately 7 days, and at 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the prosthetic tip. Only one of 136 flow studies were abnormal and only two of 136 blood-pool images demonstrated focally increased activity. All 25 prostheses (120 of 143 scans) demonstrated increased uptake on the bone phase images. The area about the tip was divided into three segments; increased uptake at 24 mo was noted in the medial, distal, and lateral segments in 16%, 72%, and 56% of prostheses, respectively. Twenty of 25 prostheses (82 of 142 scans) showed uptake on In-WBC scintigraphy, being noted in 48% of prostheses at 24 mo. We conclude that scintigraphic patterns in the uncomplicated patient with a porous coated prosthesis appear to differ from patterns described in cemented prostheses

  10. Tribology and total hip joint replacement: current concepts in mechanical simulation.

    Science.gov (United States)

    Affatato, S; Spinelli, M; Zavalloni, M; Mazzega-Fabbro, C; Viceconti, M

    2008-12-01

    Interest in the rheology and effects of interacting surfaces is as ancient as man. This subject can be represented by a recently coined word: tribology. This term is derived from the Greek word "tribos" and means the "science of rubbing". Friction, lubrication, and wear mechanism in the common English language means the precise field of interest of tribology. Wear of total hip prosthesis is a significant clinical problem that involves, nowadays, a too high a number of patients. In order to acquire further knowledge on the tribological phenomena that involve hip prosthesis wear tests are conducted on employed materials to extend lifetime of orthopaedic implants. The most basic type of test device is the material wear machine, however, a more advanced one may more accurately reproduce some of the in vivo conditions. Typically, these apparatus are called simulators, and, while there is no absolute definition of a joint simulator, its description as a mechanical rig used to test a joint replacement, under conditions approximating those occurring in the human body, is acceptable. Simulator tests, moreover, can be used to conduct accelerated protocols that replicate/simulate particularly extreme conditions, thus establishing the limits of performance for the material. Simulators vary in their level of sophistication and the international literature reveals many interpretations of the design of machines used for joint replacement testing. This paper aims to review the current state of the art of the hip joint simulators worldwide. This is specified through a schematic overview by describing, in particular, constructive solutions adopted to reproduce in vivo conditions. An exhaustive commentary on the evolution and actually existing simulation standards is proposed by the authors. The need of a shared protocol among research laboratories all over the world could lead to a consensus conference.

  11. Expression and Significance of the HIP/PAP and RegIIIγ Antimicrobial Peptides during Mammalian Urinary Tract Infection.

    Directory of Open Access Journals (Sweden)

    John David Spencer

    Full Text Available Recent evidence indicates that antimicrobial peptides (AMPs serve key roles in defending the urinary tract against invading uropathogens. To date, the individual contribution of AMPs to urinary tract host defense is not well defined. In this study, we identified Regenerating islet-derived 3 gamma (RegIIIγ as the most transcriptionally up-regulated AMP in murine bladder transcriptomes following uropathogenic Escherichia coli (UPEC infection. We confirmed induction of RegIIIγ mRNA during cystitis and pyelonephritis by quantitative RT-PCR. Immunoblotting demonstrates increased bladder and urinary RegIIIγ protein levels following UPEC infection. Immunostaining localizes RegIIIγ protein to urothelial cells of infected bladders and kidneys. Human patients with UTI have increased urine concentrations of the orthologous Hepatocarcinoma-Intestine-Pancreas / Pancreatitis Associated Protein (HIP/PAP compared to healthy controls. Recombinant RegIIIγ protein does not demonstrate bactericidal activity toward UPEC in vitro, but does kill Staphylococcus saprophyticus in a dose-dependent manner. Kidney and bladder tissue from RegIIIγ knockout mice and wild-type mice contain comparable bacterial burden following UPEC and Gram-positive UTI. Our results demonstrate that RegIIIγ and HIP/PAP expression is induced during human and murine UTI. However, their specific function in the urinary tract remains uncertain.

  12. Expression and Significance of the HIP/PAP and RegIIIγ Antimicrobial Peptides during Mammalian Urinary Tract Infection

    Science.gov (United States)

    Spencer, John David; Jackson, Ashley R.; Li, Birong; Ching, Christina B.; Vonau, Martin; Easterling, Robert S.; Schwaderer, Andrew L.; McHugh, Kirk M.; Becknell, Brian

    2015-01-01

    Recent evidence indicates that antimicrobial peptides (AMPs) serve key roles in defending the urinary tract against invading uropathogens. To date, the individual contribution of AMPs to urinary tract host defense is not well defined. In this study, we identified Regenerating islet-derived 3 gamma (RegIIIγ) as the most transcriptionally up-regulated AMP in murine bladder transcriptomes following uropathogenic Escherichia coli (UPEC) infection. We confirmed induction of RegIIIγ mRNA during cystitis and pyelonephritis by quantitative RT-PCR. Immunoblotting demonstrates increased bladder and urinary RegIIIγ protein levels following UPEC infection. Immunostaining localizes RegIIIγ protein to urothelial cells of infected bladders and kidneys. Human patients with UTI have increased urine concentrations of the orthologous Hepatocarcinoma-Intestine-Pancreas / Pancreatitis Associated Protein (HIP/PAP) compared to healthy controls. Recombinant RegIIIγ protein does not demonstrate bactericidal activity toward UPEC in vitro, but does kill Staphylococcus saprophyticus in a dose-dependent manner. Kidney and bladder tissue from RegIIIγ knockout mice and wild-type mice contain comparable bacterial burden following UPEC and Gram-positive UTI. Our results demonstrate that RegIIIγ and HIP/PAP expression is induced during human and murine UTI. However, their specific function in the urinary tract remains uncertain. PMID:26658437

  13. Bursae and abscess cavities communicating with the hip: diagnosis using arthrography and CT

    International Nuclear Information System (INIS)

    Steinbach, L.S.; Schneider, R.; Goldman, A.B.; Kazam, E.; Ranawat, C.S.; Ghelman, B.

    1985-01-01

    Bursae or abscess cavities communicating with the hip joint were demonstrated by hip arthrography or by computed tomography (CT) in 40 cases. The bursae or abscess cavities were associated with underlying abnormalities in the hip, including painful hip prostheses, infection, and inflammatory or degenerative arthritis. Symptoms may be produced directly as a result of infection or indirectly as a result of inflammation or pressure on adjacent structures. Hip arthrography can confirm a diagnosis of bursae and abscess cavities communicating with the hip joint in patients with hip pain or soft-tissue masses around the groin. Differentiation of enlarged bursae from other abnormalities is important to avoid unnecessary or incorrect surgery

  14. Detection of total hip prostheses at airport security checkpoints: how has heightened security affected patients?

    Science.gov (United States)

    Johnson, Aaron J; Naziri, Qais; Hooper, Hasan A; Mont, Michael A

    2012-04-04

    The sensitivity of airport security screening measures has increased substantially during the past decade, but few reports have examined how this affects patients who have undergone hip arthroplasty. The purpose of this study was to determine the experiences of patients who had hip prostheses and who passed through airport security screenings. A consecutive series of 250 patients who presented to the office of a high-volume surgeon were asked whether they had had a hip prosthesis for at least one year and, if so, whether they had flown on a commercial airline within the past year. Patients who responded affirmatively to both questions were asked to complete a written survey that included questions about which joint(s) had been replaced, the number of encounters with airport security, the frequency and location of metal detector activation, any additional screening procedures that were utilized, whether security officials requested documentation regarding the prosthesis, the degree of inconvenience, and other relevant information. Of the 143 patients with hip replacements who traveled by air, 120 (84%) reported triggering the alarm and required wanding with a handheld detector. Twenty-five of these patients reported subsequently having to undergo further inspection, including additional wanding, being patted down, and in two cases having to undress in a private room to show the incision. Ninety-nine (69%) of the 143 patients reported that the prosthetic joint caused an inconvenience while traveling. This study provides interesting and critical information that allows physicians to understand the real-world implications of implanted orthopaedic devices for patients who are traveling where there has been heightened security since September 11, 2001. Patients should be counseled that they should expect delays and be prepared for such inconveniences, but that these are often only momentary. This information could relieve some anxiety and concerns that patients may have

  15. Increased risk of revision for infection in rheumatoid arthritis patients with total hip replacements

    DEFF Research Database (Denmark)

    Schrama, Johannes Cornelis; Fenstad, Anne M; Dale, Håvard

    2015-01-01

    Background and purpose-Medical treatment of rheumatoid arthritis (RA) has changed dramatically over the last 15 years, including immune modulation. We investigated the risk of revision for infection after primary total hip replacement (THR) in patients with rheumatoid arthritis over a 16-year...... period, and compared it with that in THR patients with osteoarthritis (OA).Patients and methods-We identified 13,384 THRs in RA patients and 377,287 THRs in OA patients from 1995 through 2010 in a dataset from the Nordic Arthroplasty Register Association (NARA). Kaplan-Meier survival curves......, with revision for infection as the endpoint, were constructed. Cox regression analyses were performed to calculate the relative risk (RR) of revision for infection adjusted for age, sex, fixation technique, and year of primary surgery.Results-RA patients had a 1.3 times (95% CI 1.0-1.6) higher risk of revision...

  16. Dual mobility total hip arthroplasty in hemiplegic patients

    Directory of Open Access Journals (Sweden)

    Henawy Ayman T.

    2017-01-01

    Full Text Available Introduction: The rate of cerebrovascular insults is increasing, currently leaving many patients with difficulties to maintain their balance due to muscular weakness and/or poor central control. Those patients are at risk of dislocation when total hip arthroplasty (THA is planned. Instability remains the most significant issue after primary THA especially in such groups of patients. The risk is more pronounced when other factors are added such as, older age, femoral neck fractures, avascular necrosis and/or hip osteoarthritis. Dual mobility cup (DMC is considered as a prosthesis with higher inherent stability that may help in such situation. In this patient series, we aimed to evaluate stability, clinical and radiological results of dual mobility THA done on the weak limb of hemiplegic patients. Methods: Twenty-four consecutive hemiplegic patients have undergone DMC with a mean age of 68 years. The indication for surgery was hip osteoarthritis in one third of the patients and femoral neck fractures in the remaining patients. Those patients were capable of walking prior to hospital admission despite weakness. Those patients were observed postoperatively for at least one year. Clinical results and complications were recorded. Results: After a minimum of one year, 91.6% of the patients have satisfactory results. No cases of hip or intraprosthetic dislocation were observed. Discussion: Dual mobility THA in the hemiplegic patients provides both efficacy and stability with good functional results.

  17. An Adult Patient with Pneumonia Due to Aspiration of Dental Prosthesis

    Directory of Open Access Journals (Sweden)

    Samil Gunay

    2014-03-01

    Full Text Available In patients with a new and suddenly beginning of bronchial asthma and repetitive respiratory infection, one should consider the possibility of obstruction by a foreign body. In this case we present a male patient with pneumonia due to aspiration of dental prosthesis. A 32-year-old man presented with a 4-month history of dyspnea, chest pain and new    compliants of diaphoresis and fever persistend despite of antibiotic treatment. Then the patient consultated to our chest surgery department. After the physical examination of patient we made the fiberoptic  flexible bronchoscopy according to the uncertain opasity seen in the chest radiography. Later in the operating room, with the patient under general anesthesia, we extracted the aspirated foreign body, dental prosthesis, by rigid bronchoscopy. We should think about the possibility of foreign body aspiration for the patients with suddenly beginning of the complaints such as, bronchial asthma, repetitive respiratory infection, diaphoresis, chest pain and fever. Sometimes people hides the true anamnesis because of be ashamed or amnesia.

  18. Nasal prosthesis rehabilitation: a case report

    DEFF Research Database (Denmark)

    Jain, Sumeet; Maru, Kavita; Shukla, Jyotsana

    2011-01-01

    Facial defects resulting from neoplasm, congenital malformation or trauma can be restored with facial prosthesis using different materials and retention methods to achieve life-like look and function. A nasal prosthesis can re-establish esthetic form and anatomic contours for mid-facial defects...... the non-surgical rehabilitation, with polymethyl meth-acrylate resin, nasal prosthesis for a patient who received partial rhinectomy as a result of squamous cell carcinoma of the nose. The prosthesis was made to restore the esthetic appearance of the patient with a mechanical retained design using...

  19. The effect of the metal-on-metal hip controversy on internet search activity.

    LENUS (Irish Health Repository)

    Phelan, Nigel

    2014-01-04

    The recall of the articular surface replacement (ASR) hip prosthesis in 2010 represents one of the most controversial areas in orthopaedic surgery in recent years. The aim of this study was to compare the impact of the metal-on-metal hip controversy on Internet search activity in four different regions and determine whether the number of related news reports affected Internet search activity. The Google Trends, Keywords and News applications were used to record the number of news articles and Internet search activity for the terms "hip recall", "metal-on-metal hip" and "ASR hip" from October 2009 to October 2012 in the USA, the UK, Australia and Ireland. There was a large increase in search activity following the official recall in August 2010 in all countries. There was significantly greater search activity after the recall in Ireland compared with the UK for the search term "hip recall" (P = 0.004). For the term "metal-on-metal hip", the UK had significantly more search activity (P = 0.0009). There was a positive correlation between the number of news stories in UK and Ireland with Internet search activity but not in the USA or Australia. Differences between countries affected by the same recall highlight the complex effects of the media on public awareness. The data demonstrates a window of opportunity prior to the official recall for the development of an awareness campaign to provide patients with accurate information.

  20. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement.

    Science.gov (United States)

    Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D

    2015-01-01

    In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.

  1. [CLINICAL APPLICATION OF OXFORD MOBILE-BEARING BIPOLAR PROSTHESIS UNICOMPARTMENTAL KNEE ARTHROPLASTY FOR SINGLE COMPARTMENTAL KNEE OSTEOARTHRITIS].

    Science.gov (United States)

    Wang, Shangzeng; Cheng, Shao; Wang, Yisheng

    2016-01-01

    To evaluate the effectiveness of Oxford mobile-bearing bipolar prosthesis unicompartmental knee arthroplasty (UKA) in the treatment of single compartmental knee osteoarthritis. Between June 2011 and July 2013, 22 cases of single compartmental knee osteoarthritis were treated by Oxford mobile-bearing bipolar prosthesis UKA. Of 22 cases, 8 were male and 14 were female with an average age of 65 years (range, 45-80 years); the left knee was involved in 12 cases, and the right knee in 10 cases, with a mean disease duration of 32.5 months (range, 8-90 months). The mean weight was 55.2 kg (range, 50-65 kg), and the mean body mass index was 20.8 kg/m2 (range, 17-25 kg/m2). Osteoarthritis involved in the single knee medial compartment in all patients. Knee society score (KSS) and range of motion (ROM) were measured to evaluate the knee joint function. Primary healing of incision was obtained in all patients, and there was no complication of infection, bedsore, or deep venous thrombosis. Postoperative follow-up was 2-4 years (mean, 3.2 years). The X-ray films showed good position of prosthesis, no prosthesis dislocation, or periprosthetic infection during follow-up. Knee ROM, KSS function score, and KSS clinical score were significantly improved at 1 week after operation and at last follow-up when compared with preoperative ones (P 0.05). Oxford mobile-bearing bipolar prosthesis UKA is an effective method to treat single compartmental knee osteoarthritis, with the advantages of less trauma, earlier rehabilitation exercise, near physiological state in joint function, and less risk of complications.

  2. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  3. Tribology of total hip arthroplasty prostheses

    Science.gov (United States)

    Rieker, Claude B.

    2016-01-01

    Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis. A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient. Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations. All combinations of bearing surface have their advantages and disadvantages. An appraisal of the individual patient’s objectives should be part of the assessment of the best bearing surface. Cite this article: Rieker CB. Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know. EFORT Open Rev 2016;1:52-57. DOI: 10.1302/2058-5241.1.000004. PMID:28461928

  4. Chronic Periprosthetic Hip Joint Infection. A Retrospective, Observational Study on the Treatment Strategy and Prognosis in 130 Non-Selected Patients

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Søballe, Kjeld

    2016-01-01

    INTRODUCTION: Limited information is available regarding the treatment strategy and prognosis of non-selected patients treated for chronic periprosthetic hip joint infection. Such information is important as no head-to-head studies on treatment strategies are available. The purpose of this study...... is to report on the treatment strategy and prognosis of a non-selected, consecutive patient population. METHODS: We identified 130 patients in the National Patient Registry, consecutively treated for a chronic periprosthetic hip joint infection between 2003-2008 at 11 departments of orthopaedic surgery. We...... extracted information regarding patient demographics, treatment and outcome. 82 patients were re-implanted in a two-stage revision (national standard), the remaining 48 were not re-implanted in a two-stage revision. We were able to collect up-to-date information on all patients to date of death or medical...

  5. Impact of UHMWPE texture on friction and wear resistance of hip prosthesis

    Directory of Open Access Journals (Sweden)

    Eddoumy Fatima

    2013-11-01

    Full Text Available Ultra High Molecular Weight PolyEthylene (UHMWPE is a polymer widely used in hip implants (prostheses as a bearing surface against metal, because of its good mechanical properties and biocompatibility [1]. Nevertheless, the durability of such implants is limited because of failure resulting from osteolysis and aseptic loosening. These two phenomenons are due to the immune response of human body consecutive to the apparition of wear particles of UHMWPE with time.

  6. Prosthetic joint infection caused by Pasteurella multocida: a case series and review of literature.

    Science.gov (United States)

    Honnorat, Estelle; Seng, Piseth; Savini, Hélène; Pinelli, Pierre-Olivier; Simon, Fabrice; Stein, Andreas

    2016-08-20

    Pasteurella multocida is a well-recognized zoonotic agent following dog or cat bites or scratches. Nevertheless, prosthetic joint infection caused by P. multocida are rarely reported. We report here a series of six cases of prosthetic joint infection caused by P. multocida managed at a referral centre for the treatment of bone and joint infection in southern France. We also reviewed the 26 cases reported in literature. The mean age of our cases was 74 years [±8.2, range 63-85]. In majority of our cases (5 cases) were associated with knee prostheses and one case with a hip prosthesis. Most of cases occurred after cat or dog scratches or licks or contact. Diagnoses of prosthetic joint infection caused by P. multocida were made by positive cultures of surgical biopsies or needle aspiration. Mean time delay between prosthetic joint implantation and infection onset was 7.6 years (±5.12 years, range 2-17). Local inflammation, which occurred in all six cases, was the most frequent clinical symptom, followed by pain in five cases, fever and swollen joints in four cases, and a fistula with purulent discharge inside the wound in two cases. The mean time of antibiotic therapy was 8 months. Surgical treatment with prosthesis removal was performed in three cases. Six of our cases were in remission without apparent relapse at 3 years after end of treatment. Prosthetic joint infections caused by P. multocida usually occur after animal scratches or bites, but can occasionally occur after a short animal lick. These infections are usually resulting from a contiguous infection and localized in the knee. An early antibiotic therapy after surgical debridement could avoid prosthetic withdrawal, notably in elderly patients. Patients with prosthetic joints should be warned that animals are potential sources of serious infection and urgent medical advice should be sought if they are bitten or scratched.

  7. Mechanical analysis of ceramic heat being part of hip prosthesis with presence of cracks

    International Nuclear Information System (INIS)

    Ravagli, E.

    1995-03-01

    This report still pursues the aim of carrying out a systematic mechanical analysis of a ceramic heat being part of a modular hig prosthesis, in order to characterize it exhaustively, i. e. to assess its performances and some of its main specifications. A mechanical analysis of a second case is carried out here, the presence of head cracks being taken into account. The evaluations made lead to the conclusion that the head should not show cracks bigger than 100 mm. This study is performed in the frame of the STRIDE-CETMA project, which is aimed at founding and developing a centre for technologically advanced materials in Brindisi technology park (Italy)

  8. Comparison of Range of Motion After Total Knee Prosthesis According to Different Type of Prosthesis

    Directory of Open Access Journals (Sweden)

    Firat Seyfettinoglu

    2016-07-01

    Full Text Available Aim: The aim of this study is to determine the effectiveness and range of motion of different type of knee prosthesis. Material and Method: This study includes 180 of 225 patients (139 F, 41 M, average age: 65, range of age: 51-82 between April 2005 and September 2007 with the diagnosis of gonarthrosis. All patients underwent to primary total knee arthroplasty. Primary osteoartrhritis is the reason of gonarthrosis. The patients with secondary osteoartrhritis were excluded from the study. All the patients were operated by the same surgical team and rehabilitated after surgery. Patella didnt change any patient. PCL was protected in some of the patients and cut some of patients. Totally seven type prosthesis in 16 subgroup were applied to the patients. All measurement were done by the same surgeon. Average follow up period was 31 months (24-49 months. Results: Patients without subgrouping were tested according to the range of motion before and after surgery to the type of the prosthesis trademark. Range of motion was decreased with the usage of Rotaglide and LCS® type of prosthesis. Range of motion didnt change with the usage of Maxim and Kinemax type. The range of motion increased in the other trademark of prosthesis. Flexion angle was increased statistically significant with nexgen® and scorpio® prosthesis (p

  9. The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants. A phantom study

    International Nuclear Information System (INIS)

    Harnish, R.; Lang, T.F.; Prevrhal, S.; Alavi, A.; Zaidi, H.

    2014-01-01

    To determine if metal artefact reduction (MAR) combined with a priori knowledge of prosthesis material composition can be applied to obtain CT-based attenuation maps with sufficient accuracy for quantitative assessment of 18 F-fluorodeoxyglucose uptake in lesions near metallic prostheses. A custom hip prosthesis phantom with a lesion-sized cavity filled with 0.2 ml 18 F-FDG solution having an activity of 3.367 MBq adjacent to a prosthesis bore was imaged twice with a chrome-cobalt steel hip prosthesis and a plastic replica, respectively. Scanning was performed on a clinical hybrid PET/CT system equipped with an additional external 137 Cs transmission source. PET emission images were reconstructed from both phantom configurations with CT-based attenuation correction (CTAC) and with CT-based attenuation correction using MAR (MARCTAC). To compare results with the attenuation-correction method extant prior to the advent of PET/CT, we also carried out attenuation correction with 137 Cs transmission-based attenuation correction (TXAC). CTAC and MARCTAC images were scaled to attenuation coefficients at 511 keV using a trilinear function that mapped the highest CT values to the prosthesis alloy attenuation coefficient. Accuracy and spatial distribution of the lesion activity was compared between the three reconstruction schemes. Compared to the reference activity of 3.37 MBq, the estimated activity quantified from the PET image corrected by TXAC was 3.41 MBq. The activity estimated from PET images corrected by MARCTAC was similar in accuracy at 3.32 MBq. CTAC corrected PET images resulted in nearly 40% overestimation of lesion activity at 4.70 MBq. Comparison of PET images obtained with the plastic and metal prostheses in place showed that CTAC resulted in a marked distortion of the 18 F-FDG distribution within the lesion, whereas application of MARCTAC and TXAC resulted in lesion distributions similar to those observed with the plastic replica. (author)

  10. Pre-operative Predictive Factors of Post-operative Pain in Patients With Hip or Knee Arthroplasty: A Systematic Review.

    Science.gov (United States)

    Hernández, Clara; Díaz-Heredia, Jorge; Berraquero, María Luisa; Crespo, Pablo; Loza, Estíbaliz; Ruiz Ibán, Miguel Ángel

    2015-01-01

    To analyze pre-surgical predictive factors of post-surgical pain in patients undergoing hip or knee arthoplasty. A systematic literature review was performed. We defined a sensitive strategy on Medline, Embase and Cochrane Library up to May 2013. The inclusion criteria were: patients undertaking knee and/or hip arthroplasty, adults with moderate or severe pain (≥4 on a Visual Analog Scale) in whom predictive factors of post-surgical pain were evaluated before surgery. Systematic reviews, meta-analyses, controlled trials and observational studies were selected. We excluded animals and basic science articles, reviews of prosthesis, prosthesis due to fractures, patients with rheumatic diseases or studies with mixed population in which disaggregated data was not possible to obtain. A total 37 articles of moderate quality were selected. The articles included representative patients undergoing a knee or hip arthroplasty in our country; most of them were aged 60 years or above, with osteoarthritis, and with a high rate of obesity and comorbidities. We found great variability regarding the type of studies and predictive factors. There was a strong association between post-surgical pain and the following pre-surgical factors: female gender, low socio-economic status, higher pain, comorbidities, low back pain, poor functional status, and psychological factors (depression, anxiety or catastrophic pain). There are pre-surgical factors that might influence post-surgical pain in patients undergoing a knee or hip arthroplasty. Therefore, they should be taken into account when considering an arthroplasty. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  11. THE INFLUENCE OF THE SURGICAL APPROACH CONCERNING DISLOCATION IN TOTAL HIP ARTHROPLASTY.

    Science.gov (United States)

    Vicente, José Ricardo Negreiros; Pires, André Fernandes; Lee, Bruno Takasaki; Leonhardt, Marcos Camargo; Ejnisman, Leandro; Croci, Alberto Tesconi

    2009-01-01

    Our primary aim was to evaluate the occurrence of dislocation of non-cemented total hip arthroplasty, when using the posterior and the direct lateral approaches. We performed a comparative retrospective study with 232 patients submitted to non-cemented total hip arthroplasty, due to the diagnosis of primary or secondary osteoarthritis. The posterior approach was used in 105 patients while direct lateral approach was used in 127 patients. There was only one prosthesis model and the same rehabilitation program and post-operative care was used for all patients. We checked the occurrence of dislocation, the acetabular positioning and also the size of the components. There was only one case of dislocation, treated with closed reduction successfully. This was a 47 year-old female, submitted to direct lateral approach. The mean follow-up time for both groups was 23.7 months, ranging from six to 42 months. The authors conclude that the prevalence of total hip arthroplasty dislocation is similar for both approaches, and educational measures besides the use of a higher femoral offset seem to reduce the risk of this complication.

  12. Reduction of metallosis in hip implant using thin film coating

    Science.gov (United States)

    Rajeshshyam, R.; Chockalingam, K.; Gayathri, V.; Prakash, T.

    2018-04-01

    Hip implant finds its emerging attraction due to it continuous demand over the years. The hip implants (femoral head) and acetabulum cup) mainly fabricated by metals such as stainless steel, cobalt chrome and titanium alloys, other than that ceramics and polyethylene have been used. The metal-on-metal hip implant was found to be best implant material for most of the surgeons due to its high surface finish, low wear rate and low chance of dislocation from its position after implanting. Where in metal based hip implant shows less wear rate of 0.01mm3/year. Metal-on-metal implant finds its advantage over other materials both in its mechanical and physical stability against human load. In M-O-M Cobalt- chromium alloys induce metal allergy. The metal allergy (particulate debris) that is generated by wear, fretting, fragmentation and which is unavoidable when a prosthesis is implanted, can induce an inflammatory reaction in some circumstances. The objectives of this research to evaluate thin film coating with Nano particle additives to reduce the wear leads to regarding metal ion release. Experimental results reveals that thin film Sol-Gel coating with 4wt. % of specimen reduced the cobalt and chromium ion release and reduces the wear rate. Wear rate reduced by 98% for 4wt. % graphene in 20N and 95% for 4wt. % graphene in 10N.

  13. Implant-Retained Auricular Prosthesis: A Case Report

    OpenAIRE

    Ozturk, A. Nilgun; Usumez, Aslihan; Tosun, Zekeriya

    2010-01-01

    Extraoral implant retained prosthesis have been proven to be a predictable treatment option for maxillofacial rehabilitation. This case report describes the clinical and laboratory procedures for fabricating an auricular prosthesis. In this case report, an auricular prosthesis was fabricated for a patient who lost the left and right external ear in an electrical burn. Extraoral implants and bar-and-clip retention for the proper connection of the auricular prosthesis to implant were used. This...

  14. Permanent Quadriplegia Following Replacement of Voice Prosthesis.

    Science.gov (United States)

    Ozturk, Kayhan; Erdur, Omer; Kibar, Ertugrul

    2016-11-01

    The authors presented a patient with quadriplegia caused by cervical spine abscess following voice prosthesis replacement. The authors present the first reported permanent quadriplegia patient caused by voice prosthesis replacement. The authors wanted to emphasize that life-threatening complications may be faced during the replacement of voice prosthesis. Care should be taken during the replacement of voice prosthesis and if some problems have been faced during the procedure patients must be followed closely.

  15. Laser-assisted fixation of a nitinol stapes prosthesis.

    Science.gov (United States)

    Schrötzlmair, Florian; Suchan, Fabian; Pongratz, Thomas; Krause, Eike; Müller, Joachim; Sroka, Ronald

    2018-02-01

    Otosclerosis is an inner ear bone disease characterized by fixation of the stapes and consequently progressive hearing loss. One treatment option is the surgical replacement of the stapes by a prosthesis. When so called "smart materials" like nitinol are used, prosthesis fixation can be performed using a laser without manual crimping on the incus. However, specific laser-prosthesis interactions have not been described yet. The aim of the present study was to elucidate the thermo-mechanical properties of the NiTiBOND® prosthesis as a basis for handling instructions for laser-assisted prosthesis fixation. Closure of the NiTiBOND® prosthesis was induced ex vivo by either a diode laser emitting at λ = 940 nm or a CO 2 laser (λ = 10,600 nm). Total energy for closure was determined. Suitable laser parameters (pulse duration, power per pulse, distance between tip of the laser fiber and prosthesis) were assessed. Specific laser-prosthesis interactions were recorded. Especially the diode laser was found to be an appropriate energy source. A total energy deposit of 60 mJ by pulses in near contact application was found to be sufficient for prosthesis closure ex vivo. Energy should be transmitted through a laser fiber equipollent to the prosthesis band diameter. Specific deformation characteristics due to the zonal prosthesis composition have to be taken into account. NiTiBOND® stapes prosthesis can be closed by very little energy when appropriate energy sources like diode lasers are used, suggesting a relatively safe application in vivo. Lasers Surg. Med. 50:153-157, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. CUSTOM TRIFLANGE ACETABULAR COMPONENTS IN REVISION HIP REPLACEMENT (EXPERIENCE REVIEW

    Directory of Open Access Journals (Sweden)

    A. A. Korytkin

    2017-01-01

    Full Text Available Extensive defects of acetabulum especially accompanied by pelvis discontinuity at the level of acetabulum pose a serious challenge in revision hip replacement and create additional complexity in fixing the acetabular component. One of the perspective options to solve the above issue is the use of custom triflange acetabular components (CTAC designed based on preoperative computer tomography given the specifics of bone defects of the patient. Purpose of the study — to evaluate the outcomes of CTAC use in revision hip replacement.Materials and methods. The authors analyzed treatment outcomes of 12 patients after revision hip replacement using additive techniques of computer simulation and 3D printing CTAC. Follow up period after the surgery averaged 7±3 months (from one to ten months. 7 out of 12 patients had acetabular defects of Paprosky 3B type, 4 patients had defects of Paprosky 3A and in one patient — of Paprosky 2C.Results. Two out of twelve patients had prosthesis dislocations that required revision hip surgery, one of those patients underwent open reduction of dislocation with wound debridement, another patient underwent replacement of articulating couple of acetabular component. Total scores under Harris Hip Score and paint VAS score prior to treatment was 28±7 and 7±1 points respectively, postoperative scores were 76±9 and 3±1 respectively.Conclusion. The application of additive techniques for revision hip replacement in patients with extensive acetabular and pelvic defects allows to make a precise preoperative planning, to restore joint rotation center, to reconstruct bone defects and to securely fix triflange acetabular component that altogether significantly improve treatment outcomes and patients satisfaction with the surgery.

  17. Tantalum acetabular augments in one-stage exchange of infected total hip arthroplasty: a case-control study.

    Science.gov (United States)

    Klatte, Till Orla; Kendoff, Daniel; Sabihi, Reza; Kamath, Atul F; Rueger, Johannes M; Gehrke, Thorsten

    2014-07-01

    During the one-stage exchange procedure for periprosthetic joint infection (PJI) after total hip arthroplasty (THA), acetabular defects challenge reconstructive options. Porous tantalum augments are an established tool for addressing acetabular destruction in aseptic cases, but their utility in septic exchange is unknown. This retrospective case-control study presents the initial results of tantalum augmentation during one-stage exchange for PJI. Primary endpoints were rates of re-infection and short-term complications associated with this technique. Study patients had no higher risk of re-infection with equivalent durability at early follow-up with a re-infection rate in both groups of 4%. In conclusion, tantalum augments are a viable option for addressing acetabular defects in one-stage exchange for septic THA. Further study is necessary to assess long-term durability when compared to traditional techniques for acetabular reconstruction. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Analysis of {sup 18} F-FDG uptake patterns in PET for diagnosis of septic and aseptic loosening after total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Cremerius, U.; Niethard, F.U. [Rheinisch-Westfaelische Technische Hochschule Aachen (Germany). Klinik fuer Nuklearmedizin; Mumme, T.; Reinartz, P.; Wirtz, D. [Rheinisch-Westfaelische Technische Hochschule Aachen (Germany). Orthopaedische Klinik; Buell, U.

    2003-12-01

    Aim: Identification of typical patterns for fluorodeoxyglucose (FDG) uptake in positron emission tomography (PET) to detect aseptic loosening of hip prosthesis (acetabular and/or femoral component) and prosthetic infection. Methods: 18 patients with painful hip prosthesis underwent PET using a dedicated full ring scanner after application of 200-300 MBq FDG. The interface between bone and surrounding soft tissue or bone as displayed on coronal slices was divided into 12 segments in accordance with the classifications of Delee and Gruen. FDG uptake in each of the segments was scored (0-3) by two independent observers. Intraoperative findings were regarded as the gold standard. Results: After surgical revision 14 acetabular components and 9 femoral components were found to be loose and prosthetic infection was present in 7 prostheses. Loosening of the acetabular component was correlated to enhanced uptake in the middle of the acetabular interface, while loosening of the femoral component was correlated to enhanced uptake in the proximal and middle segment of the lateral femoral interface and the proximal segment of the medial femoral interface. A similar pattern was found in prosthetic infection with high uptake along the middle portion of the lateral femoral interface. In 6 of 7 infected prostheses loosening of the acetabular and of the femoral component was present. Taking the typical uptake patterns as criteria for loosening and grade 3 uptake as an additional criterion for septic loosening the accuracy of PET imaging in the detection of loosening of the acetabular or the femoral component and of prosthetic infection was 72, 78 and 89%, respectively. Conclusion: This pilot study presents FDG-PET as a promising diagnostic tool for patients with painful hip prostheses. Its clinical value should be evaluated in a larger patient population. (orig.) [German] Ziel: Identifikation von Befundmustern in der Positronenemissionstomographie (PET) mit {sup 18}F

  19. Chest-wall reconstruction with a customized titanium-alloy prosthesis fabricated by 3D printing and rapid prototyping.

    Science.gov (United States)

    Wen, Xiaopeng; Gao, Shan; Feng, Jinteng; Li, Shuo; Gao, Rui; Zhang, Guangjian

    2018-01-08

    As 3D printing technology emerge, there is increasing demand for a more customizable implant in the repair of chest-wall bony defects. This article aims to present a custom design and fabrication method for repairing bony defects of the chest wall following tumour resection, which utilizes three-dimensional (3D) printing and rapid-prototyping technology. A 3D model of the bony defect was generated after acquiring helical CT data. A customized prosthesis was then designed using computer-aided design (CAD) and mirroring technology, and fabricated using titanium-alloy powder. The mechanical properties of the printed prosthesis were investigated using ANSYS software. The yield strength of the titanium-alloy prosthesis was 950 ± 14 MPa (mean ± SD), and its ultimate strength was 1005 ± 26 MPa. The 3D finite element analyses revealed that the equivalent stress distribution of each prosthesis was unifrom. The symmetry and reconstruction quality contour of the repaired chest wall was satisfactory. No rejection or infection occurred during the 6-month follow-up period. Chest-wall reconstruction with a customized titanium-alloy prosthesis is a reliable technique for repairing bony defects.

  20. Predictors of revision, prosthetic joint infection and mortality following total hip or total knee arthroplasty in patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Cordtz, Rene Lindholm; Zobbe, Kristian; Højgaard, Pil

    2018-01-01

    OBJECTIVES: To investigate predictors of 10-year risk of revision and 1-year risk of prosthetic joint infection (PJI) and death following total hip/total knee arthroplasty (THA/TKA) in (1) patients with rheumatoid arthritis (RA) compared with patients with osteoarthritis (OA); and (2) patients...

  1. 21 CFR 872.3960 - Mandibular condyle prosthesis.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3960 Mandibular condyle prosthesis. (a) Identification. A mandibular condyle prosthesis is a device that is intended to be implanted in the human jaw to... requirement for premarket approval for any mandibular condyle prosthesis intended to be implanted in the human...

  2. [A method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck].

    Science.gov (United States)

    Chen, Tao; Shang, Xifu; He, Rui; Hu, Fei; Ge, Chang

    2012-03-01

    To investigate the method to avoid lengthening lower limbs after total hip arthroplasty in patients with congenital short femoral neck. The clinical data were analyzed retrospectively from 38 patients undergoing unilateral total hip arthroplasty between April 2005 and December 2010. There were 26 males and 12 females, aged 45-78 years (mean, 62.3 years). Among these cases, there were 11 cases of avascular necrosis of the femoral head, 17 cases of hip osteoarthritis, and 10 cases of femoral neck fracture. Before operation, 29 cases had leg length discrepancy; and the shortened length of the legs was 10-24 mm with an average of 14.5 mm by clinical measurement, and was 11-25 mm with an average of 14.7 mm by X-ray film measurement. The Harris score before operation was 44.0 +/- 3.6. At 1 day after operation, 3 cases had legs lengthening by clinical and X-ray film measurement; limb length difference less than 10 mm was regarded as equal limb length in the other 35 patients (92.1%). All incisions healed by first intention, and no complication of infection or lower limb deep venous thrombosis occurred. In 3 patients who had legs lengthening, 1 patient had abnormal gait and slight limping after increasing heel pad because the lower limb was lengthened by 16 mm, and 2 patients had slight limping. The other patients could walk normally and achieved pain relief of hip. Thirty-six patients were followed up 12-68 months (mean, 43.8 months). The Harris score was 86.7 +/- 2.3 after 6 months, showing significant difference (t = 3.260, P = 0.031) when compared with that before operation. The X-ray films showed no prosthetic loosening or subsidence. For patients with congenital short femoral neck during total hip arthroplasty, the surgeons should pay attention to osteotomy plane determination, limb length measurement, and use of the prosthesis with collar to avoid the lengthening lower limbs.

  3. Friction in total hip joint prosthesis measured in vivo during walking.

    Science.gov (United States)

    Damm, Philipp; Dymke, Joern; Ackermann, Robert; Bender, Alwina; Graichen, Friedmar; Halder, Andreas; Beier, Alexander; Bergmann, Georg

    2013-01-01

    Friction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used. In vivo measurements were taken 3 months post operatively in 8 subjects. The coefficient of friction was calculated in 3D throughout the whole gait cycle, and average values of the friction-induced power dissipation in the joint were determined. On average, peak contact forces of 248% of the bodyweight and peak friction moments of 0.26% bodyweight times meter were determined. However, contact forces and friction moments varied greatly between individuals. The friction moment increased during the extension phase of the joint. The average coefficient of friction also increased during this period, from 0.04 (0.03 to 0.06) at contralateral toe off to 0.06 (0.04 to 0.08) at contralateral heel strike. During the flexion phase, the coefficient of friction increased further to 0.14 (0.09 to 0.23) at toe off. The average friction-induced power throughout the whole gait cycle was 2.3 W (1.4 W to 3.8 W). Although more parameters than only the synovia determine the friction, the wide ranges of friction coefficients and power dissipation indicate that the lubricating properties of synovia are individually very different. However, such differences may also exist in natural joints and may influence the progression of arthrosis. Furthermore, subjects with very high power dissipation may be at risk of thermally induced implant loosening. The large increase of the friction coefficient during each step could be caused by the synovia being squeezed out under load.

  4. Friction in total hip joint prosthesis measured in vivo during walking.

    Directory of Open Access Journals (Sweden)

    Philipp Damm

    Full Text Available Friction-induced moments and subsequent cup loosening can be the reason for total hip joint replacement failure. The aim of this study was to measure the in vivo contact forces and friction moments during walking. Instrumented hip implants with Al2O3 ceramic head and an XPE inlay were used. In vivo measurements were taken 3 months post operatively in 8 subjects. The coefficient of friction was calculated in 3D throughout the whole gait cycle, and average values of the friction-induced power dissipation in the joint were determined. On average, peak contact forces of 248% of the bodyweight and peak friction moments of 0.26% bodyweight times meter were determined. However, contact forces and friction moments varied greatly between individuals. The friction moment increased during the extension phase of the joint. The average coefficient of friction also increased during this period, from 0.04 (0.03 to 0.06 at contralateral toe off to 0.06 (0.04 to 0.08 at contralateral heel strike. During the flexion phase, the coefficient of friction increased further to 0.14 (0.09 to 0.23 at toe off. The average friction-induced power throughout the whole gait cycle was 2.3 W (1.4 W to 3.8 W. Although more parameters than only the synovia determine the friction, the wide ranges of friction coefficients and power dissipation indicate that the lubricating properties of synovia are individually very different. However, such differences may also exist in natural joints and may influence the progression of arthrosis. Furthermore, subjects with very high power dissipation may be at risk of thermally induced implant loosening. The large increase of the friction coefficient during each step could be caused by the synovia being squeezed out under load.

  5. Tissue expander infections in children: look beyond the expander pocket.

    Science.gov (United States)

    Mason, A C; Davison, S P; Manders, E K

    1999-11-01

    Infection of the expander pocket is the most common complication encountered with soft-tissue expansion. It is usually due to direct inoculation with skin flora either at the time of expander insertion or from extrusion of the device. The authors report two cases of infection of tissue expanders in which the children had concomitant infected sites distant from the prosthesis. Etiological bacteria of common pediatric infections like otitis media and pharyngitis were cultured from the infected expander pocket, raising suspicion that translocation of the organism to the expander had occurred. Aggressive antibiotic treatment, removal of the prosthesis, and flap advancement is advocated.

  6. Tubing erosion of an inflatable penile prosthesis long after implantation.

    Science.gov (United States)

    Morales, Alvaro

    2014-06-01

    Erosion through skin of connecting tubing of an inflatable penile prosthesis (IPP) has not been previously reported. The aim of this study was to present a case of tubing erosion, review the pertinent literature, and discuss the possible causes and management options, including preservation of the device and its components. A 42-year-old male failing to respond to medical treatment for erectile dysfunction underwent insertion of an AMS 700 IPP in 1986. Six years later, a revision was necessary because of a leak in the right cylinder and 4 years after, the pump was replaced. Fourteen years after the original implant, he presented with a portion of the tube connecting the pump to the right cylinder eroding through the skin. There was no infection. The skin area involved was resected and the original pump and tubing were buried in a new scrotal pocket after thorough irrigation. The IPP remained in place, allowing vaginal penetration and without infection for another 11 years. Three years later, it was de-functionalized, converted into a fixed volume device. It eventually was replaced 25 years after originally implanted with a semirigid prosthesis because it did not provide sufficient rigidity and because of concerns about the presence of "screws" detected during pelvic imaging. Mechanical failures in the early IPP models, as illustrated in this case, were expected. However, the long survival of the device is remarkable. Erosion of the connecting tubing through the skin is unique and, under exceptional circumstances, may be managed conservatively without replacing components of the IPP. Clinicians unfamiliar with procedures involving inflatable devices need to be aware of "foreign bodies" visible in radiological examinations in men who have had revisions of an IPP. Morales A. Tubing erosion of an inflatable penile prosthesis long after implantation. Sex Med 2014;2:103-106.

  7. Identification of bacteria on the surface of clinically infected and non-infected prosthetic hip joints removed during revision arthroplasties by 16S rRNA gene sequencing and by microbiological culture

    Science.gov (United States)

    Dempsey, Kate E; Riggio, Marcello P; Lennon, Alan; Hannah, Victoria E; Ramage, Gordon; Allan, David; Bagg, Jeremy

    2007-01-01

    It has been postulated that bacteria attached to the surface of prosthetic hip joints can cause localised inflammation, resulting in failure of the replacement joint. However, diagnosis of infection is difficult with traditional microbiological culture methods, and evidence exists that highly fastidious or non-cultivable organisms have a role in implant infections. The purpose of this study was to use culture and culture-independent methods to detect the bacteria present on the surface of prosthetic hip joints removed during revision arthroplasties. Ten consecutive revisions were performed by two surgeons, which were all clinically and radiologically loose. Five of the hip replacement revision surgeries were performed because of clinical infections and five because of aseptic loosening. Preoperative and perioperative specimens were obtained from each patient and subjected to routine microbiological culture. The prostheses removed from each patient were subjected to mild ultrasonication to dislodge adherent bacteria, followed by aerobic and anaerobic microbiological culture. Bacterial DNA was extracted from each sonicate and the 16S rRNA gene was amplified with the universal primer pair 27f/1387r. All 10 specimens were positive for the presence of bacteria by both culture and PCR. PCR products were then cloned, organised into groups by RFLP analysis and one clone from each group was sequenced. Bacteria were identified by comparison of the 16S rRNA gene sequences obtained with those deposited in public access sequence databases. A total of 512 clones were analysed by RFLP analysis, of which 118 were sequenced. Culture methods identified species from the genera Leifsonia (54.3%), Staphylococcus (21.7%), Proteus (8.7%), Brevundimonas (6.5%), Salibacillus (4.3%), Methylobacterium (2.2%) and Zimmermannella (2.2%). Molecular detection methods identified a more diverse microflora. The predominant genus detected was Lysobacter, representing 312 (60.9%) of 512 clones

  8. Dosimetry of a silicone breast prosthesis

    International Nuclear Information System (INIS)

    McGinley, P.H.; Powell, W.R.; Bostwick, J.

    1980-01-01

    Dose measurements were conducted in a phantom which simulates breast tissue and in another phantom which simulates a breast containing a silicone prosthesis. No detectable difference was found when the irradiations were carried out with tangential beams of 60 Co radiation. The degree of backscatter and absorption of radiation by the prosthesis and phantom were also similar. A slight decrease in dose of approximately 8% was found at the interface between the prosthesis and muscle-equivalent material

  9. Duocentric® reversed shoulder prosthesis and Personal Fit® templates: innovative strategies to optimize prosthesis positioning and prevent scapular notching.

    Science.gov (United States)

    Trouilloud, P; Gonzalvez, M; Martz, P; Charles, H; Handelberg, F; Nyffeler, R W; Baulot, E

    2014-05-01

    We describe our experience with a new system of patient-specific template called Personal Fit(®), which is unique in shoulder surgery and used in combination with Duocentric(®) prosthesis. The reverse prosthesis's concept is the invention of Paul Grammont, developed with Grammont's team of Dijon University as from 1981, which led to the first reversed total shoulder prosthesis called Trumpet in 1985. The Duocentric(®) prosthesis developed in 2001 is the third-generation prosthesis, coming from the Trumpet and the second-generation prosthesis Delta(®) (DePuy). This prosthesis provides a novel solution to the notching problem with an inferior overhang integrated onto the glenoid baseplate. Personal Fit(®) system is based on reconstructing the shoulder joint bones in three dimensions using CT scan data, placing a landmark on the scapula and locating points on the glenoid and humerus. That will be used as a reference for the patient-specific templates. We study the glenoid position planned with Personal Fit(®) software relative to native glenoid position in 30 cases. On average, the difference between the planned retroversion (or anteversion in one case) and native retroversion was 8.6°.

  10. Hip fusion takedown to a total hip arthroplasty-is it worth it? A systematic review.

    Science.gov (United States)

    Jauregui, Julio J; Kim, Joseph K; Shield, William P; Harb, Matthew; Illical, Emmanuel M; Adib, Farshad; Maheshwari, Aditya V

    2017-08-01

    Patients with surgically or spontaneously fused hips are often dissatisfied with their overall function and the debilitating effect on adjacent joints. Therefore, in properly selected patients, hip fusion-takedown and conversion to total hip arthroplasty (THA) can result in improved function and decreased pain. We aimed to (1) evaluate the indications for conversion, (2) evaluate the clinical outcomes, (3) analyze the overall complications, and (4) identify the overall satisfaction following the procedure. A systematic and comprehensive literature search was performed to analyze studies evaluating conversion of hip fusion to THA. After reviewing 3,882 studies, 27 total studies (1,104 hips) met our inclusion/exclusion criteria and were included in our final analysis. A weighted mean of rates was determined for each complication, including infection, instability, loosening, nerve-related, abductor-related, venous thrombotic event, and revision. The study population consisted of 53.2% male and 46.8% female subjects. The mean age at time of conversion was 52 years (range 36-65 years), the mean time until follow-up was 9.2 years (range 2.5-17.3), and the mean duration of arthrodesis was 27.7 years (range 11-40.2). As measured by Harris Hip Score, overall clinical outcomes improved from 58.1 points (range 42.4-70 points) pre-operatively to 80.0 (range 62-93.5) post-operatively. The specific complication rates were 5.3% (range 0-43.6%) for infection, 2.6% (range 0-15.4%) for instability, 6.2% (range 0-17.2%) for loosening, 4.7% (range 0-13%) for nerve-related complications, 13.1% (range 0-87%) for abductor-related complications, and 1.2% (range 0-13%) for venous thrombotic events. The revision rate was 12.0% (range 0-43.6%). Takedown of a fused-hip can be a challenging procedure. Although patients can benefit functionally, both patients and surgeons need to be aware of the complications and increased risk of further revision procedures, which should be an important

  11. Malrotation of the McGhan Style 510 prosthesis.

    NARCIS (Netherlands)

    Schots, J.M.; Fechner, M.R.; Hoogbergen, M.M.; Tits, H.W.H.J.

    2010-01-01

    BACKGROUND: Anatomically shaped cohesive silicone breast implants are frequently used in aesthetic and reconstructive surgery. After successful results with the Style 410 prosthesis, McGhan (Natrelle, Allergan) introduced the Style 510 prosthesis. After using this novel prosthesis, the authors

  12. Total hip arthroplasty revision due to infection: a cost analysis approach.

    Science.gov (United States)

    Klouche, S; Sariali, E; Mamoudy, P

    2010-04-01

    The treatment of total hip arthroplasty (THA) infections is long and costly. However,the number of studies in the literature analysing the real cost of THA revision in relation to their etiology, including infection, is limited. The aim of this retrospective study was to determine the cost of revision of infected THA and to compare these costs to those of primary THA and revision of non-infected THA. We performed a retrospective cost analysis for the year 2006 using an identical analytic accounting system in each hospital department (according to internal criteria) based on allotment of direct costs and receipts for each department. From January to December 2006, 424 primary THA, 57 non-infected THA revisions and 40 THA revisions due to infection were performed. The different cost areas of the patient's treatment were identified.This included preoperative medical work-up, medicosurgical management during hospital stay,a second stay in an orthopedic rehabilitation hospital (ORH) and post-hospitalisation antibiotic therapy after revision due to infection, as well as home-based hospitalisation (HH) costs, if this was the selected alternative option. We used the national health insurance fee schedule found in the "Common classification of medical procedures" and the "General nomenclature of professional procedures" applicable in France since September 1, 2005. Hospital costs included direct costs (hospital overhead costs) and indirect costs, (medical, surgical, technical settings and net general service expenses). The calculation of HH costs and ORH costs were based on the average daily charge of these departments. The cost of primary THA was used as the reference.We then compared our surgical costs with those found for the corresponding comparable hospital stay groups (Groupes homogènes de séjour). The average hospital stay (AHS) was 7.5 +/- 1.8 days for primary THA, 8.9 +/- 2.2 days for non-infected revisions and 30.6 +/- 14.9 days for revisions due to infection

  13. Finger prosthesis: a boon to handicapped.

    Science.gov (United States)

    Gupta, Ridhima; Kumar, Lakshya; Rao, Jitendra; Singh, Kamleshwar

    2013-08-29

    This is a clinical case report of a 52-year-old male patient with four partially missing fingers of the left hand. The article describes the clinical and laboratory procedure of making prosthesis with modern silicone material. A wax pattern was fabricated using the right hand of the patient. A special type of wax was formulated to make the pattern so that it can be easily moulded and carved. Intrinsic and extrinsic staining was also performed to match the adjacent skin colour. The patient was given the finger prosthesis and was asked to use a half glove (sports) to mask the junction between the prosthesis and the normal tissue. It also provides additional retention to the artificial fingers. The patient felt his social acceptance improved after wearing the finger prosthesis.

  14. 21 CFR 878.3800 - External aesthetic restoration prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External aesthetic restoration prosthesis. 878... External aesthetic restoration prosthesis. (a) Identification. An external aesthetic restoration prosthesis... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...

  15. Rehabilitation of a Patient with an Intra Oral Prosthesis and an Extra Oral Orbital Prosthesis Retained with Magnets

    OpenAIRE

    Pattanaik, Seema; Wadkar, Aarti P.

    2011-01-01

    This clinical case report deals with a rehabilitation of a patient with an extensive maxillary and orbital defect using an intra oral prosthesis obturating the maxillary defect and extra oral orbital prosthesis retained with rare-earth magnets for secondary retention; primary retention was derived by snug fit of the prosthesis to underlying and adjacent tissues. The rehabilitation resulted in improved function, esthetics and comfort to the patient thus enabling him to lead a normal life.

  16. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis

    International Nuclear Information System (INIS)

    Jin, H.; Yuan, L.; Li, C.; Kan, Y.; Yang, J.; Hao, R.

    2014-01-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  17. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis.

    Science.gov (United States)

    Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J

    2014-03-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  18. The Talar Body Prosthesis: Results at Ten to Thirty-six Years of Follow-up.

    Science.gov (United States)

    Harnroongroj, Thos; Harnroongroj, Thossart

    2014-07-16

    Satisfactory results of implantation of the talar body prosthesis were reported in 1997, although some complications associated with the initial design were noted. The present study evaluated outcomes of treatment with a modified talar body prosthesis. Of the thirty-six talar body prostheses implanted with use of a transmalleolar surgical approach from 1974 to 2011, thirty-three were available for follow-up at ten to thirty-six years or had failed prior to that time. The indication for implantation had been osteonecrosis in twenty-three patients, a comminuted talar fracture in eight, and a talar body tumor in two. Twenty-eight of the thirty-three prostheses were still in place at the time of final follow-up and five had failed prior to five years. The duration of follow-up was ten to twenty years in eight patients, twenty to thirty years in eleven, and thirty to thirty-six years in nine. The AOFAS (American Orthopaedic Foot & Ankle Society) ankle-hindfoot score did not differ significantly among these three groups. Patients over sixty-five years of age with underlying disease that impeded walking ability had lower AOFAS scores. Early prosthesis failure occurred as a result of size mismatch in two patients, tumor recurrence in one, infection in one, and osteonecrosis of the talar head and neck in one. These failures, which occurred at eight to fifty-seven months, were treated with tibiotalar arthrodesis in three patients, prosthesis revision in one, and below-the-knee amputation in one. Although early prosthesis failure may occur, survival of the talar body prosthesis can provide satisfactory ankle and foot function. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  19. Volume Replacement Therapy during Hip Arthroplasty using Hydroxyethyl Starch (130/0.4 Compared to Lactated Ringer Decreases Allogeneic Blood Transfusion and Postoperative Infection

    Directory of Open Access Journals (Sweden)

    Adilson Hamaji

    2013-01-01

    Full Text Available Background and objectives: Hydroxyethyl starch (HES 130/0.4 is considered an effective plasma expander when compared to crystalloids. There is controversy around its superiority regarding hemodynamic optimization and about possible detrimental effects on coagulation. The aim of this study was to compare the effects of HES 130/0.4 to lactated Ringer solution during hip arthroplasty in adult patients under spinal anesthesia regarding intraoperative bleeding, hemodynamic parameters, coagulation profile, transfusion requirements and clinical outcomes. Methods: In this randomized, controlled trial, 48 patients scheduled for hip arthroplasty with spinal anesthesia were randomized into two groups: 24 patients were allocated to receive a preload of 15 mL.kg-1 of HES 130/0.4 and 24 patients received a preload of 30 mL.kg-1 lactated Ringer solution before surgery. Hemodynamic measurements, hemoglobin concentrations, biochemical parameters and coagulation tests were evaluated in three periods during surgical procedure. Patients received medical follow-up during their hospital stay and up to postoperative 30 days. Primary outcome was the requirement of red blood cell transfusion between groups during hospital stay. Secondary outcome were hemodynamic parameters, length of hospital stay, mortality and occurrence of clinical postoperative complications. Results: Red blood cell transfusion was required in 17% of patients in the HES group and in 46% in the Ringer group (p = .029. Postoperative infections were more frequently observed in the Ringer group (17% compared to the HES group (0, p = .037. There were no significant differences between groups in mortality, hospital length of stay and clinical complications other than infection. Conclusions: During hip arthroplasty, patients treated with hypervolemic hemodilution with hydroxyethyl starch 130/0.4 required less transfusion and presented lower infection rate compared to patients who received lactated

  20. Lobule separator prosthesis to prevent adhesion of reconstructed ear lobe

    Directory of Open Access Journals (Sweden)

    Lokendra Gupta

    2016-01-01

    Full Text Available An adhesion is a band of scar tissue that binds two parts of the tissue together, which develops when the body's repair mechanisms respond to any tissue disturbance, such as surgery, infection, trauma, or radiation. Prevention of unwanted scar bands is of utmost importance to develop esthetic and healthy tissue. This article describes a technique to prevent the adhesion of the surgically reconstructed ear lobule with facial skin, using novel lobule separator prosthesis.

  1. Attachment-retained gingival prosthesis for implant-supported fixed dental prosthesis in the maxilla: a clinical report.

    Science.gov (United States)

    Aparecida de Mattias Sartori, Ivete; Uhlendorf, Yuri; Padovan, Luiz Eduardo Marques; Junior, Paulo Domingos Ribeiro; Melo, Ana Cláudia Moreira; Tiossi, Rodrigo

    2014-12-01

    The rehabilitation of edentulous maxillae is a complex procedure due to the involvement of esthetic and functional requirements. A trial maxillary denture can be used to identify the need for adequate upper lip support when replacing removable complete dentures by implant-fixed dental prostheses. This clinical report describes the outcome of the rehabilitation of an edentulous atrophic maxilla with unfavorable maxillomandibular relationship and deficient upper lip support. A trial denture was fabricated and used to diagnose the need for a prosthesis capable of restoring the upper lip support. The reduced upper lip support was also confirmed by a lateral cephalogram. The patient was rehabilitated by an implant-fixed dental prosthesis associated with an attachment-retained gingival prosthesis. The case presented shows that when loss of upper lip support is detected and the patient does not wish to undergo further surgical reconstruction procedure, the retention of a gingival prosthesis using a ball attachment is a satisfactory treatment option. © 2014 by the American College of Prosthodontists.

  2. Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 cases in 10 dogs (1991-1995)

    International Nuclear Information System (INIS)

    Edwards, M.R.; Egger, E.L.; Schwarz, P.D.

    1997-01-01

    Objective-To determine clinical signs, radiographic findings, results of surgical management, and potential causes of aseptic loosening of the femoral implant (ALFI) in dogs that have undergone cemented total hip arthroplasty (THA). Design-Retrospective study. Animals-11 cases of ALFI in 10 dogs. Procedure-Medical records of all dogs undergoing THA revision surgery were reviewed. Only dogs with ALFI were included. The prosthesis and cement were removed by creating a longitudinal osteotomy of the cranial femoral cortex. Postoperative radiographs of all dogs that underwent THA during the study period were reviewed. Results-The most common clinical sign was intermittent, subtle. or non-weight-bearing lameness. On radiographs obtained after THA, contact of the distal stem tip with cortical endosteum was evident in all dogs. Radiographic changes at the time of diagnosis of ALFI included asymmetric periosteal reaction along the femoral diaphysis, radiolucent lines between the prosthesis and cement, altered implant position, and femoral fracture. Surgical revision yielded good or excellent results in 9 cases. In 1 dog. the implant became infected; in another, aseptic loosening recurred. Aseptic loosening was significantly more common in dogs in which there was contact between the distal stem tip and cortical endosteum than in dogs in which there was no contact. Clinical Implications-ALFI is an uncommon, but important, complication of THA, and radiography is warranted in dogs with clinical signs of ALFI. Initial centering of the prosthetic stem within the femoral shaft may reduce the incidence of ALFI

  3. Comparative study of fat-suppression techniques for hip arthroplasty MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Moliere, Sebastien [University Hospital of Strasbourg, Imaging Department, Strasbourg (France); Dillenseger, Jean-Philippe; Kremer, Stephane; Bierry, Guillaume [University Hospital of Strasbourg, Imaging Department, Strasbourg (France); ICube UMR 7357, University of Strasbourg, Strasbourg (France); Ehlinger, Matthieu [ICube UMR 7357, University of Strasbourg, Strasbourg (France); University Hospital of Strasbourg, Orthopaedic Department, Strasbourg (France)

    2017-09-15

    The goal of this study was to evaluate different fat-suppressed fluid-sensitive sequences in association with different metal artifacts reduction techniques (MARS) to determine which combination allows better fat suppression around metallic hip implants. An experimental study using an MRI fat-water phantom quantitatively evaluated contrast shift induced by metallic hip implant for different fat-suppression techniques and MARS. Then a clinical study with patients addressed to MRI unit for painful hip prosthesis compared these techniques in terms of fat suppression quality and diagnosis confidence. Among sequences without MARS, both T2 Dixon and short tau inversion recuperation (STIR) had significantly lower contrast shift (p < 0.05), Dixon offering the best fat suppression. Adding MARS (view-angle tilting or slice-encoding for metal artifact correction (SEMAC)) to STIR gave better results than Dixon alone, and also better than SPAIR and fat saturation with MARS (p < 0.05). There were no statistically significant differences between STIR with view-angle tilting and STIR with SEMAC in terms of fat suppression quality. STIR sequence is the preferred fluid-sensitive MR sequence in patients with metal implant. In combination with MARS (view-angle tilting or SEMAC), STIR appears to be the best option for high-quality fat suppression. (orig.)

  4. Comparative study of fat-suppression techniques for hip arthroplasty MR imaging.

    Science.gov (United States)

    Molière, Sébastien; Dillenseger, Jean-Philippe; Ehlinger, Matthieu; Kremer, Stéphane; Bierry, Guillaume

    2017-09-01

    The goal of this study was to evaluate different fat-suppressed fluid-sensitive sequences in association with different metal artifacts reduction techniques (MARS) to determine which combination allows better fat suppression around metallic hip implants. An experimental study using an MRI fat-water phantom quantitatively evaluated contrast shift induced by metallic hip implant for different fat-suppression techniques and MARS. Then a clinical study with patients addressed to MRI unit for painful hip prosthesis compared these techniques in terms of fat suppression quality and diagnosis confidence. Among sequences without MARS, both T2 Dixon and short tau inversion recuperation (STIR) had significantly lower contrast shift (p < 0.05), Dixon offering the best fat suppression. Adding MARS (view-angle tilting or slice-encoding for metal artifact correction (SEMAC)) to STIR gave better results than Dixon alone, and also better than SPAIR and fat saturation with MARS (p < 0.05). There were no statistically significant differences between STIR with view-angle tilting and STIR with SEMAC in terms of fat suppression quality. STIR sequence is the preferred fluid-sensitive MR sequence in patients with metal implant. In combination with MARS (view-angle tilting or SEMAC), STIR appears to be the best option for high-quality fat suppression.

  5. Comparative study of fat-suppression techniques for hip arthroplasty MR imaging

    International Nuclear Information System (INIS)

    Moliere, Sebastien; Dillenseger, Jean-Philippe; Kremer, Stephane; Bierry, Guillaume; Ehlinger, Matthieu

    2017-01-01

    The goal of this study was to evaluate different fat-suppressed fluid-sensitive sequences in association with different metal artifacts reduction techniques (MARS) to determine which combination allows better fat suppression around metallic hip implants. An experimental study using an MRI fat-water phantom quantitatively evaluated contrast shift induced by metallic hip implant for different fat-suppression techniques and MARS. Then a clinical study with patients addressed to MRI unit for painful hip prosthesis compared these techniques in terms of fat suppression quality and diagnosis confidence. Among sequences without MARS, both T2 Dixon and short tau inversion recuperation (STIR) had significantly lower contrast shift (p < 0.05), Dixon offering the best fat suppression. Adding MARS (view-angle tilting or slice-encoding for metal artifact correction (SEMAC)) to STIR gave better results than Dixon alone, and also better than SPAIR and fat saturation with MARS (p < 0.05). There were no statistically significant differences between STIR with view-angle tilting and STIR with SEMAC in terms of fat suppression quality. STIR sequence is the preferred fluid-sensitive MR sequence in patients with metal implant. In combination with MARS (view-angle tilting or SEMAC), STIR appears to be the best option for high-quality fat suppression. (orig.)

  6. Dose attenuation effect of hip prostheses in a 9-MV photon beam. Commercial treatment planning system versus Monte Carlo calculations

    International Nuclear Information System (INIS)

    Mesbahi, A.; Nejad, F.S.

    2007-01-01

    The purpose of this study was to investigate the dosimetric effect of various hip prostheses on pelvis lateral fields treated by a 9-MV photon beam using Monte Carlo (MC) and effective path-length (EPL) methods. The head of the Neptun 10 pc linac was simulated using the MCNP4C MC code. The accuracy of the MC model was evaluated using measured dosimetric features including depth dose values and dose profiles in a water phantom. The Alfard treatment planning system (TPS) was used for EPL calculations. A virtual water phantom with dimensions of 30 x 30 x 30 cm 3 and a cube with dimensions of 4 x 4 x 4 cm 3 made of various metals centered in 12 cm depth was used for MC and EPL calculations. Various materials including titanium, Co-Cr-Mo, and steel alloys were used as hip prostheses. Our results showed significant attenuation in absorbed dose for points after and inside the prostheses. Attenuations of 32%, 54% and 55% were seen for titanium, Co-Cr-Mo, and steel alloys, respectively, at a distance of 5 cm from the prosthesis. Considerable dose increase (up to 18%) was found at the water-prosthesis interface due to back-scattered electrons using the MC method. The results of EPL calculations for the titanium implant were comparable to the MC calculations. This method, however, was not able to predict the interface effect or calculate accurately the absorbed dose in the presence of the Co-Cr-Mo and steel prostheses. The dose perturbation effect of hip prostheses is significant and cannot be predicted accurately by the EPL method for Co-Cr-Mo or steel prostheses. The use of MC-based TPS is recommended for treatments requiring fields passing through hip prostheses. (author)

  7. Propionibacterium avidum as an Etiological Agent of Prosthetic Hip Joint Infection.

    Directory of Open Access Journals (Sweden)

    Peter Wildeman

    Full Text Available Propionibacterium acnes is well-established as a possible etiologic agent of prosthetic joint infections (PJIs. Other Propionibacterium spp. have occasionally been described as a cause of PJIs, but this has not previously been the case for P. avidum despite its capacity to form biofilm. We describe two patients with prosthetic hip joint infections caused by P. avidum. Both patients were primarily operated with an anteriorly curved skin incision close to the skin crease of the groin, and both were obese. Initial treatment was performed according to the DAIR procedure (debridement, antibiotics, and implant retention. In case 1, the outcome was successful, but in case 2, a loosening of the cup was present 18 months post debridement. The P. avidum isolate from case 1 and two isolates from case 2 (obtained 18 months apart were selected for whole genome sequencing. The genome of P. avidum obtained from case 1 was approximately 60 kb larger than the genomes of the two isolates of case 2. These latter isolates were clonal with the exception of SNPs in the genome. All three strains possessed the gene cluster encoding exopolysaccharide synthesis. P. avidum has a pathogenic potential and the ability to cause clinically relevant infections, including abscess formation, in the presence of foreign bodies such as prosthetic joint components. Skin incision in close proximity to the groin or deep skin crease, such as the anteriorly curved skin incision approach, might pose a risk of PJIs by P. avidum, especially in obese patients.

  8. Two-Stage Progressive Femoral Lowering Followed by Cementless Total Hip Arthroplasty for Treating Crowe IV-Hartofilakidis Type 3 Developmental Dysplasia of the Hip.

    Science.gov (United States)

    Binazzi, Roberto

    2015-05-01

    High developmental dysplasia of the hip is commonly treated with total hip arthroplasty and shortening osteotomy. We present a two stage technique, consisting of progressive femoral lowering followed by total hip arthroplasty. The clinico-radiographic results of eleven patients (twelve hips) who were operated on with the two-stage technique were evaluated at a mean follow-up of 11 ± 5 years. At the final follow-up, ten patients (eleven hips) had a mean Harris hip score of 85 ± 5 points with no implant loosening. One patient (one hip) was revised at 5 years due to infection. No neurovascular complications were observed in any patients. With this technique, we could place the cup in the anatomical position and obtain complete limb symmetry with excellent clinical results at long-term. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. 5-year clinical and radiostereometric analysis (RSA) follow-up of 39 CUT femoral neck total hip prostheses in young osteoarthritis patients

    Science.gov (United States)

    2012-01-01

    Background As the number of young patients receiving total hip arthroplasty increases, bone-saving implantations facilitating possible future revision, such as the CUT femoral neck prosthesis, are gaining importance. There have been few medium-term results reported for this prosthesis, however, and its migration pattern has not been analyzed. Patients and methods 39 consecutive CUT femoral neck prostheses were implanted in 32 patients, mean age 37 (17–58) years, with symptomatic osteoarthritis and either less than 55 years of age or with an anatomic anomaly preventing implantation of a diaphyseal stem (n = 1). Patients were followed prospectively using routine clinical examination and radiostereometric analysis (RSA) at 6, 12, 26, and 52 weeks postoperatively and annually thereafter. This study evaluated the 5-year follow-up results. Results The mean Harris hip score increased from 26 (3–51) points preoperatively to 84 (66–98), 86 (55–98), and 87 (47–98) points at 3, 12, and 60 months. 3 stems were revised: 1 after luxation following excessive subsidence due to an undersized component and 2 due to persistent strong thigh pain. 5-year survival was 95% (95% CI: 87–100). Initial migration varied widely in magnitude; median total tip migration was 0.42 mm (0.09–9.4) at 6 weeks, 0.92 mm (0.18–5.9) at 1 year, and 1.10 mm (0.13–6.4) at 5 years. Even after high initial migration, stabilization was achieved in 31 of the 35 RSA-evaluable implants. 3 prostheses showed progressive continuous migration throughout the entire follow-up period, and were considered to be loose, suggesting reduced long-term survival. Interpretation Currently, we cannot recommend the CUT femoral neck prosthesis as a routine treatment option in (young) patients requiring THA. The CUT prosthesis may not reach the 90% survival benchmark at 10 years, and the prosthesis is difficult to implant. If initial stabilization is achieved, however, aseptic loosening is unlikely. A good clinical

  10. 21 CFR 872.3950 - Glenoid fossa prosthesis.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3950 Glenoid fossa prosthesis. (a) Identification. A glenoid fossa prosthesis is a device that is intended to be implanted in the temporomandibular...

  11. Intra-articular steroid injection for osteoarthritis of the hip prior to total hip arthroplasty : is it safe? a systematic review.

    Science.gov (United States)

    Pereira, L C; Kerr, J; Jolles, B M

    2016-08-01

    Using a systematic review, we investigated whether there is an increased risk of post-operative infection in patients who have received an intra-articular corticosteroid injection to the hip for osteoarthritis prior to total hip arthroplasty (THA). Studies dealing with an intra-articular corticosteroid injection to the hip and infection following subsequent THA were identified from databases for the period between 1990 to 2013. Retrieved articles were independently assessed for their methodological quality. A total of nine studies met the inclusion criteria. Two recommended against a steroid injection prior to THA and seven found no risk with an injection. No prospective controlled trials were identified. Most studies were retrospective. Lack of information about the methodology was a consistent flaw. The literature in this area is scarce and the evidence is weak. Most studies were retrospective, and confounding factors were poorly defined or not addressed. There is thus currently insufficient evidence to conclude that an intra-articular corticosteroid injection administered prior to THA increases the rate of infection. High quality, multicentre randomised trials are needed to address this issue. Cite this article: Bone Joint J 2016;98-B:1027-35. ©2016 The British Editorial Society of Bone & Joint Surgery.

  12. Optimization of metal artefact reduction (MAR) sequences for MRI of total hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Toms, A.P., E-mail: andoni.toms@nnuh.nhs.u [Department of Radiology, Norfolk and Norwich University Hospital Trust, Norwich, Norfolk NR4 7UY (United Kingdom); Smith-Bateman, C.; Malcolm, P.N.; Cahir, J. [Department of Radiology, Norfolk and Norwich University Hospital Trust, Norwich, Norfolk NR4 7UY (United Kingdom); Graves, M. [University Department of Radiology, Addenbrooke' s Hospital, Cambridge (United Kingdom)

    2010-06-15

    Aim: To describe the relative contribution of matrix size and bandwidth to artefact reduction in order to define optimal sequence parameters for metal artefact reduction (MAR) sequences for MRI of total hip prostheses. Methods and materials: A phantom was created using a Charnley total hip replacement. Mid-coronal T1-weighted (echo time 12 ms, repetition time 400 ms) images through the prosthesis were acquired with increasing bandwidths (150, 300, 454, 592, and 781 Hz/pixel) and increasing matrixes of 128, 256, 384, 512, 640, and 768 pixels square. Signal loss from the prosthesis and susceptibility artefact was segmented using an automated tool. Results: Over 90% of the achievable reduction in artefacts was obtained with matrixes of 256 x 256 or greater and a receiver bandwidth of approximately 400 Hz/pixel or greater. Thereafter increasing the receiver bandwidth or matrix had little impact on reducing susceptibility artefacts. Increasing the bandwidth produced a relative fall in the signal-to-noise ratio (SNR) of between 49 and 56% for a given matrix, but, in practice, the image quality was still satisfactory even with the highest bandwidth and largest matrix sizes. The acquisition time increased linearly with increasing matrix parameters. Conclusion: Over 90% of the achievable metal artefact reduction can be realized with mid-range matrices and receiver bandwidths on a clinical 1.5 T system. The loss of SNR from increasing receiver bandwidth, is preferable to long acquisition times, and therefore, should be the main tool for reducing metal artefact.

  13. Low infection rate after tumor hip arthroplasty for metastatic bone disease in a cohort treated with extended antibiotic prophylaxis

    DEFF Research Database (Denmark)

    Hettwer, Werner H; Horstmann, Peter Frederik; Hovgaard, Thea Bechmann

    2015-01-01

    tumor resection for metastatic bone disease during a 4-year period from 2010 to 2013 (n = 105 patients). Results. Intravenous antibiotic prophylaxis was administrated for an extended duration of a mean of 7.4 days. The overall infection rate was 3.6% (4/111 implants), infection free survival was 96...... suggest that extended postoperative antibiotic prophylaxis may reduce the risk of PJI in patients undergoing tumor resection and endoprosthetic replacement for metastatic bone disease associated impending or de facto pathologic fractures of the proximal femur.......Background. Compared to conventional hip arthroplasty, endoprosthetic reconstruction after tumor resection is associated with a substantially increased risk of periprosthetic joint infection (PJI), with reported rates of around 10% in a recent systematic review. The optimal duration of antibiotic...

  14. One-stage or two-stage revision surgery for prosthetic hip joint infection--the INFORM trial: a study protocol for a randomised controlled trial.

    Science.gov (United States)

    Strange, Simon; Whitehouse, Michael R; Beswick, Andrew D; Board, Tim; Burston, Amanda; Burston, Ben; Carroll, Fran E; Dieppe, Paul; Garfield, Kirsty; Gooberman-Hill, Rachael; Jones, Stephen; Kunutsor, Setor; Lane, Athene; Lenguerrand, Erik; MacGowan, Alasdair; Moore, Andrew; Noble, Sian; Simon, Joanne; Stockley, Ian; Taylor, Adrian H; Toms, Andrew; Webb, Jason; Whittaker, John-Paul; Wilson, Matthew; Wylde, Vikki; Blom, Ashley W

    2016-02-17

    Periprosthetic joint infection (PJI) affects approximately 1% of patients following total hip replacement (THR) and often results in severe physical and emotional suffering. Current surgical treatment options are debridement, antibiotics and implant retention; revision THR; excision of the joint and amputation. Revision surgery can be done as either a one-stage or two-stage operation. Both types of surgery are well-established practice in the NHS and result in similar rates of re-infection, but little is known about the impact of these treatments from the patient's perspective. The main aim of this randomised controlled trial is to determine whether there is a difference in patient-reported outcome measures 18 months after randomisation for one-stage or two-stage revision surgery. INFORM (INFection ORthopaedic Management) is an open, two-arm, multi-centre, randomised, superiority trial. We aim to randomise 148 patients with eligible PJI of the hip from approximately seven secondary care NHS orthopaedic units from across England and Wales. Patients will be randomised via a web-based system to receive either a one-stage revision or a two-stage revision THR. Blinding is not possible due to the nature of the intervention. All patients will be followed up for 18 months. The primary outcome is the WOMAC Index, which assesses hip pain, function and stiffness, collected by questionnaire at 18 months. Secondary outcomes include the following: cost-effectiveness, complications, re-infection rates, objective hip function assessment and quality of life. A nested qualitative study will explore patients' and surgeons' experiences, including their views about trial participation and randomisation. INFORM is the first ever randomised trial to compare two widely accepted surgical interventions for the treatment of PJI: one-stage and two-stage revision THR. The results of the trial will benefit patients in the future as the main focus is on patient-reported outcomes: pain, function

  15. Prosthetic joint infection caused by Granulicatella adiacens: a case series and review of literature.

    Science.gov (United States)

    Quénard, Fanny; Seng, Piseth; Lagier, Jean-Christophe; Fenollar, Florence; Stein, Andreas

    2017-06-23

    Bone and joint infection involving Granulicatella adiacens is rare, and mainly involved in cases of bacteremia and infectious endocarditis. Here we report three cases of prosthetic joint infection involving G. adiacens that were successfully treated with surgery and prolonged antimicrobial treatment. We also review the two cases of prosthetic joint infection involving G. adiacens that are reported in the literature. Not all five cases of prosthetic joint infection caused by G. adiacens were associated with bacteremia or infectious endocarditis. Dental care before the onset of infection was observed in two cases. The median time delay between arthroplasty implantation and the onset of infection was of 4 years (ranging between 2 and 10 years). One of our cases was identified with 16srRNA gene sequencing, one case with MALDI-TOF mass spectrometry, and one case with both techniques. Two literature cases were diagnosed by 16srRNA gene sequencing. All five cases were cured after surgery including a two-stage prosthesis exchange in three cases, a one-stage prosthesis exchange in one case, and debridement, antibiotics, irrigation, and retention of the prosthesis in one case, and prolonged antimicrobial treatment. Prosthetic joint infection involving G. adiacens is probably often dismissed due to difficult culture or misdiagnosis, in particular in the cases of polymicrobial infection. Debridement, antibiotics, irrigation, and retention of the prosthesis associated with prolonged antimicrobial treatment (≥ 8 weeks) should be considered as a treatment strategy for prosthetic joint infection involving G. adiacens.

  16. Measurement of installation deformation of the acetabulum during prosthetic replacement of a hip joint using digital image correlation

    Science.gov (United States)

    Lei, Dong; Bai, Pengxiang; Zhu, Feipeng

    2018-01-01

    Nowadays, acetabulum prosthesis replacement is widely used in clinical medicine. However, there is no efficient way to evaluate the implantation effect of the prosthesis. Based on a modern photomechanics technique called digital image correlation (DIC), the evaluation method of the installation effect of the acetabulum was established during a prosthetic replacement of a hip joint. The DIC method determines strain field by comparing the speckle images between the undeformed sample and the deformed counterpart. Three groups of experiments were carried out to verify the feasibility of the DIC method on the acetabulum installation deformation test. Experimental results indicate that the installation deformation of acetabulum generally includes elastic deformation (corresponding to the principal strain of about 1.2%) and plastic deformation. When the installation angle is ideal, the plastic deformation can be effectively reduced, which could prolong the service life of acetabulum prostheses.

  17. Criterio de predicción de la vida útil de la prótesis total de cadera en función de la falla del cemento en el componente femoral. // Life prediction criteria of hip prosthesis according to cement failure in femoral component.

    Directory of Open Access Journals (Sweden)

    G. García del pino

    2002-09-01

    Full Text Available En este trabajo se utiliza el Método de los Elementos Finitos para estudiar la combinación de diferentes parámetros, y suinfluencia en la vida útil de la prótesis total de cadera utilizando como criterio la falla del cemento que une estas prótesis alfémur, debido a que este tipo de falla es una de las fallas que mas provoca la perdida de la implantación. Los parámetrosestudiados aquí fueron el tipo de material del vástago de la prótesis dado por su modulo de elasticidad, la calidad del huesodada por la densidad y las cargas simulando diferentes actividades físicas y diferentes pesos del cuerpo.Los resultados obtenidos a través del Método de los Elementos Finitos, fueron procesados utilizando rutinas creadas enlenguaje C y técnicas de estadística, determinando las variables más influyentes y los valores más favorables para obteneruna transmisión apropiada de cargas, que garanticen una vida útil mayor.Palabras claves: biomecánica, ortopedia, elementos finitos, modulación__________________________________________________________________AbstractIn this paper the Finite Element Method is employ in order to study different parameters combination and their influence inthe duration of total hip prosthesis, taking as decision criteria the failure of cement that keep together femur and prosthesis,taking in account that this is the most common cause of implantation lost. The target parameters were: shank prosthesismaterial given by elasticity modulus, bone quality given by density, and finally, loads simulating different physicalactivities and body weight. The results were processed by means of statistical techniques and C language routines allowingto obtain the more influent variables to a proper load transmission and greater useful prosthesis life.Key words: Biomechanics, orthopaedic, finite elements, modulation

  18. Failed total carpometacarpal joint prosthesis of the thumb

    DEFF Research Database (Denmark)

    Hansen, Torben Bæk; Homilius, Morten

    2010-01-01

    Total joint prosthesis in carpometacarpal joint arthritis of the thumb often fails. Loosening of the implant is often treated by resection arthroplasty, and we reviewed 10 patients, mean age 54 years (range 47-63) who were treated by resection arthroplasty after a failed total joint prosthesis. T...... in eight of 10 patients, but the mean Disabilities of the arm, shoulder, and hand (DASH) scores, self-reported pinch-grip-related function, and pain were comparable with our earlier published results with the Elektra carpometacarpal total joint prosthesis.......Total joint prosthesis in carpometacarpal joint arthritis of the thumb often fails. Loosening of the implant is often treated by resection arthroplasty, and we reviewed 10 patients, mean age 54 years (range 47-63) who were treated by resection arthroplasty after a failed total joint prosthesis....... The male:female ratio was 1:4 and the mean duration of observation 32 months (range 6-52). In three patients the revised implant was a MOJE uncemented carpometacarpal joint prosthesis and in seven patients an Elektra uncemented one. At follow-up grip strength was reduced to less than 90% of the other hand...

  19. Stretch due to Penile Prosthesis Reservoir Migration

    Directory of Open Access Journals (Sweden)

    E. Baten

    2016-03-01

    Full Text Available A 43-year old patient presented to the emergency department with stretch, due to impossible deflation of the penile prosthesis, 4 years after successful implant. A CT-scan showed migration of the reservoir to the left rectus abdominis muscle. Refilling of the reservoir was inhibited by muscular compression, causing stretch. Removal and replacement of the reservoir was performed, after which the prosthesis was well-functioning again. Migration of the penile prosthesis reservoir is extremely rare but can cause several complications, such as stretch.

  20. Bone scintigraphy as a process control with hemi-alloarthroplasty of the hip joint

    International Nuclear Information System (INIS)

    Shaltout, E.E.D.

    1983-01-01

    For the diagnostic of prosthesis complications in the treatment of femur fractures near the hip joint ('intermediate prostheses') 216 skeletal scintigrams with 99mTc MDP were made of 143 patients from 1977 to 1982, partially retrospective and partially prospective. The evaluation of the photoscan was achieved visually and photodensitometrically and divided into 10 intensity levels with the following results: 1. Increased activity concentration in the acetabulum is pathological (activated arthrosis); 2. Increased activity concentration-temporary or also continuous - in the trochanter region is pathological (loosening process); 3. Non-pathological metabolic activity as a result of the bone healing process may last longer than 1 year postoperatively; 4. Heterotopic ossification, non-fixed bone fragments and pseudoarthrosis cause continuous or newly appearing concentrations; 5. Skeletal scintigraphy is an important supplement to radiological diagnostic and a sensitive method for the recognition of metabolic activities in bone. It is recommended for progress control after hemi-alloarthrosculpture of the hip joint. (orig./TRV) [de

  1. Rehabilitation of amputed thumb with a silicone prosthesis

    OpenAIRE

    Asnani, Pooja; Shivalingappa, Chandu Giriyapura; Mishra, Sunil Kumar; Somkuwar, Kirti; Khan, Faisal

    2015-01-01

    Creating prosthesis, having realistic skin surface and seamless visual integration with the surrounding tissues, requires both artistic and technical skill. Anatomical design, thin margins, lifelike fingernails and realistic color/contours are essential for patient satisfaction. Prosthesis is especially useful in case of lost body parts, as reconstructive surgery cannot fully restore aesthetics. This case report describes a simple technique for fabricating silicon finger prosthesis for a pati...

  2. Development and clinical application of a new testicular prosthesis.

    Science.gov (United States)

    Ning, Ye; Cai, Zhikang; Chen, Huixing; Ping, Ping; Li, Peng; Wang, Zhong; Li, Zheng

    2011-11-01

    A new type of testicular prosthesis made of silastic with an elliptical shape to mimic a normal testis was developed by our team and submitted for patenting in China. The prosthesis was produced in different sizes to imitate the normal testis of the patient. To investigate the effects and safety of the testicular prosthesis, 20 patients receiving testicular prosthesis implantation were recruited for this study. Follow-up after 6 months revealed no complications in the patients. All the patients answered that they were satisfied with their body image and the position of the implants, 19 patients were satisfied with the size and 16 patients were satisfied with the weight. These results show that the testicular prosthesis used in this study can meet patient's expectations. Patients undergoing orchiectomy should be offered the option to receive a testicular prosthesis implantation. The dimensions and weight of the available prosthetic implants should be further addressed to improve patient satisfaction.

  3. Different techniques in fabrication of ocular prosthesis.

    Science.gov (United States)

    Cevik, Pinar; Dilber, Erhan; Eraslan, Oguz

    2012-11-01

    Loss of an eye caused by cancer, trauma, or congenital defect creates a deep psychological impact on an individual's life especially social and professional life. Custom-made prosthesis, compared to stock prosthesis, provides a better fit to the eye socket, better cosmetic results, and less discomfort to the patient in the long term. The main objective of this article was to describe 3 different alternative and practical techniques of fabricating custom-made ocular prosthesis. An impression of anophthalmic socket was made with the addition of cured silicone-based precision impression material in all techniques. A master cast was prepared and duplicated with condensation silicone. A self-cure acrylic resin was polymerized in the silicone model and was fitted into the patient's eye socket. A digital photograph of the patient's iris was made using a digital camera and printed on good-quality photo paper in various shades and sizes in the first and the second techniques. Then the photo paper was coated with PVC so as not to allow any color flowing. The proper iris was then inserted to the acrylic base. The prosthesis was final processed using orthodontic heat polymerizing clear acrylic resin.In the other technique, after the trying-in process with wax pattern, an acrylic base was fabricated using heat polymerizing scleral acrylic resin. The prosthetic iris was fabricated from a transparent contact lens by painting the lens with watercolor paints and attaching it to an acrylic resin with tissue conditioner. The final process was made with heat polymerizing transparent acrylic resin. Custom-made prosthesis allows better esthetic and functional results to the patient in comparison to stock prosthesis. Further follow-up is necessary to check the condition and fit of the ocular prosthesis in such patients.

  4. Imaging of hip joint arthroplasty

    International Nuclear Information System (INIS)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C.

    2009-01-01

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [de

  5. Current antibiotic management of prosthetic joint infections in Italy: the 'Udine strategy'.

    Science.gov (United States)

    Bassetti, Matteo; Cadeo, Barbara; Villa, Giovanni; Sartor, Assunta; Cainero, Vanni; Causero, Araldo

    2014-09-01

    The rate of prosthetic joint infections followed and cured at our institution is constantly increasing, in line with epidemiological data from the recent literature. This is probably related to the greater number of knee and hip prostheses implanted every year. For intermediate and late infections, only the two-stage approach is applied, as this demonstrates the best outcome in our experience. Particular attention is paid to microbiological isolation of the pathogen: multiple samples of tissue are collected during the interventions, and kept in culture for a longer period of time than usual. Sonication of prosthetic devices is used to enhance the sensitivity and specificity of the microbiological cultures. Histological examination influences surgical choices either towards implantation of a new prosthesis or replacement of the spacer. An empirical antibiotic backbone of a glycopeptide/lipopeptide and rifampicin is chosen, due to the leading role of Gram-positive bacteria in this setting and the high incidence of methicillin resistance in our centre (>30%), followed by an antibiotic regimen containing linezolid. If specific risk factors are present, an anti-Gram-negative drug is added to the regimen. Duration of therapy depends upon the approach that is chosen, usually being 6 weeks when the prosthesis is removed. Despite at the moment being limited by its small sample size, data from our experience confirms that our empirical approach may represent a valid choice during the early phase of treatment, by keeping linezolid for a step-down therapy of shorter duration (4 weeks). © The Author 2014. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  6. Kinematic analysis of a posterior-stabilized knee prosthesis.

    Science.gov (United States)

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-20

    The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  7. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    Directory of Open Access Journals (Sweden)

    Zhi-Xin Zhao

    2015-01-01

    Full Text Available Background: The goal of total knee arthroplasty (TKA is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Results: Both the output data trends and the measured values derived from the normal knee′s kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  8. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    Science.gov (United States)

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-01

    Background: The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0–135° flexion. Results: Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, “rollback” compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis. PMID:25591565

  9. Prosthetic management of mid-facial defect with magnet-retained silicone prosthesis.

    Science.gov (United States)

    Buzayan, Muaiyed M

    2014-02-01

    Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication. To provide an aesthetic and stable facial prosthesis, the extra-oral prosthesis was fabricated using silicone material, while the intra-oral defect was restored with obturator prosthesis, and then both prostheses were connected and attached to each other using magnets. This clinical report describes the rehabilitation of a large mid-facial defect with a two-piece prosthesis. The silicone facial prosthesis was made hollow and lighter by using an acrylic framework. Two acrylic channels were included within the facial prosthesis to provide the patient with clean and patent airways. A sectional mid-facial prosthesis was made and retained in place by using magnets, which resulted in a significant improvement in the aesthetical and functional outcome without the need for plastic surgery. Silicone prostheses are reliable alternatives to surgery and should be considered in selected cases.

  10. Cold forging stem of total hip prosthesis with hybrid mechanical properties

    International Nuclear Information System (INIS)

    Lopes, E.S.N.; Contieri, R.J.; Cardoso, F.F.; Cremasco, A.; Button, S.T.; Caram, R.

    2010-01-01

    Type β Ti alloy is one of the most versatile groups of materials with regard to mechanical properties. Aspects such as alloying elements selection, mechanical processing and heat treatment routes empower these materials in applications where hybrid mechanical behavior is necessary. The aim of this study is to produce stems of total hip prostheses with hybrid mechanical properties using Ti-Nb alloys. Ingots were produced by using arc melting. Following, samples were subjected to specific heat treatment aiming to make cold forging. Sample characterization includes X-ray diffraction, scanning electron microscopy, Vickers hardness tests and tensile test. The experiments performed allowed to examine the effects of heat treatment parameters on the microstructure and mechanical behavior. Finally, results obtained show that the application of specific heat treatments of quenching and aging makes feasible the manufacturing of orthopedic devices with hybrid mechanical properties with regions where high mechanical strength was prioritized, while in others, low elastic modulus was the main concern. (author)

  11. Retrospective Study on External Canine Limb Prosthesis used in 24 patients

    Directory of Open Access Journals (Sweden)

    Brittany Jean Carr

    2018-03-01

    .g. rotating or slippage, quality of mobility comparing pre-prosthetic mobility to post-prosthetic mobility, prosthetic integrity, client’s post-prosthetic mobility expectations, complications encountered post-prosthetic application, and client’s perspective of patient’s quality of life comparing pre-prosthetic and post-prosthetic placement. Results: Of the 76 patients who were identified for this study and received a survey, survey information was obtained for 24 patients. There were 50% (n=12 forelimbs affected and 50% (n=12 hind limbs affected. Bilateral hind limb prosthesis was found in 8.33% (n=2 of the 24 cases included. Causes for the prosthesis were found to be due to trauma in 37.5% (n=9 of cases, congenital causes in 37.5% (n=9 of cases, neoplasia in 16.66% (n=4 of cases, infectious in 4.17% (n=1 of cases, and unknown in 4.17% (n=1 of cases. Of the 24 patients, 50% (n=12 of clients felt the prosthesis had an excellent fit; 20.83% (n=5 felt the prosthesis had a good fit; 16.67% (n=4 felt the prosthesis had an acceptable fit; 4.17% (n=1 felt the prosthesis had a less than satisfactory fit; lastly, 8.33% (n=2 felt the prosthetic had a poor fit. Of the 24 patients, 91.66% (n=22 were able to stand using the prosthesis; 87.5% (n=21 were able to walk using the prosthesis; 79.17% (n=19 were able to trot using the prosthesis; 70.83% (n=17 were able to climb stairs using the prosthesis; 54.17% (n=13 were able to jump on or off furniture using the prosthesis; 79.17% (n=19 were able to play fetch using the prosthesis.  From these cases, 50% (n=12 of clients felt the patient’s mobility improved post-prosthetic placement. Expectations were met in 70.83% (n=17 of cases; expectations were somewhat met in 4.17% (n=1 of cases; expectations were not met in 25% (n=6 of cases.  Prosthetic migration affected 37.5% (n=9 of cases; residuum sore or infection affected 20.83% (n=5; refusal to use the prosthetic limb occurred in 20.83% (n=5 of cases; concurrent

  12. Body image and prosthesis satisfaction in the lower limb amputee.

    OpenAIRE

    Murray, Craig; Fox, Jezz

    2002-01-01

    Purpose: This study examines the relationship between prosthesis satisfaction and body image in lower limb prosthesis users, and the gendered variations within these relationships. Method: A total of 44 valid responses were obtained to an Internet survey regarding prosthesis satisfaction, body image, and phantom pain. Spearman Rho correlations were calculated for these three domains. Results: Moderate to high negative correlations were observed between Body Image Disturbance and Prosthesis Sa...

  13. Self-contained inflatable penile prosthesis: magnetic resonance appearance

    International Nuclear Information System (INIS)

    Levin, M.F.; Munk, P.L.; Vellet, A.D.; Chin, J.L.

    1994-01-01

    The appearance of an inflatable penile prosthesis, visualized on a short tau inversion recovery sequence, is reported, in a patient who had magnetic resonance imaging for pelvic pain subsequent to radical cystoprostatectomy for bladder carcinoma. With suppression of adjacent fat signal, the prosthesis is well delineated from adjacent structures. The fluid-containing cylinders of the prosthesis are of very bright signal intensity, with the relief valve assembly of low signal intensity. 5 refs., 2 figs

  14. Fabrication of temporary speech bulb prosthesis: A clinical report

    OpenAIRE

    Kasim Mohamed, K.; Anand Kumar, V.; Devi, N.; Padmanaban, T. V.

    2010-01-01

    Maxillofacial prosthesis is an art and science which not only replaces the lost structure sometimes it restores the functions also. Pharyngeal obturator is a prosthesis which closes the palatal and pharyngeal defects and improving the speech and other function. The following case report discusses palatopharyngeal insufficiency, impression procedures, fabrication of prosthesis and improvements in speech.

  15. Closed-eye orbital prosthesis: a clinical report.

    Science.gov (United States)

    Hatamleh, Muhanad M; Watson, Jason; Srinivasan, Dilip

    2015-03-01

    One of the most challenging prostheses to fabricate is an acceptable orbital prosthesis. Successful reconstruction of the complex missing tissues, the globe, muscle, skin, and bony elements requires time and high levels of practical skill. A good match to the contralateral nondefect side will help mask the underlying defect and give the patient confidence to return to normal, routine life. The contralateral eye opening will commonly dictate the eye opening of such a prosthesis, but because of the expressive nature of the eye and its high levels of mobility, this can be difficult to achieve. This clinical report presents a patient who had an extended orbital exenteration and right maxillectomy to remove a maxillary squamous cell carcinoma. An alternative approach to constructing an orbital prosthesis was undertaken with the eye closed. Compared to the normal method of fabrication, this process was less complex and quicker, made the prosthesis less "staring," camouflaged the defect, and reduced the detection of the prosthesis because of movements in the remaining eye. The patient engaged in his routine daily life, which reinforced his self-esteem, confidence, and reintegration into the community. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Split-Framework in Mandibular Implant-Supported Prosthesis

    Directory of Open Access Journals (Sweden)

    Danny Omar Mendoza Marin

    2015-01-01

    Full Text Available During oral rehabilitation of an edentulous patient with an implant-supported prosthesis, mandibular flexure must be considered an important biomechanical factor when planning the metal framework design, especially if implants are installed posterior to the interforaminal region. When an edentulous mandible is restored with a fixed implant-supported prosthesis connected by a fixed full-arch framework, mandibular flexure may cause needless stress in the overall restorative system and lead to screw loosening, poor fit of prosthesis, loss of the posterior implant, and patient’s discomfort due to deformation properties of the mandible during functional movements. The use of a split-framework could decrease the stress with a precise and passive fit on the implants and restore a more natural functional condition of the mandible, helping in the longevity of the prosthesis. Therefore, the present clinical report describes the oral rehabilitation of an edentulous patient by a mandibular fixed implant-supported prosthesis with a split-framework to compensate for mandibular flexure. Clinical Significance. The present clinical report shows that the use of a split-framework reduced the risk of loss of the posterior implants or screws loosening with acceptable patient comfort over the period of a year. The split-framework might have compensated for the mandibular flexure during functional activities.

  17. A study of TiN-coated metal-on-polymer bearing materials for hip prosthesis

    Science.gov (United States)

    Lee, Sung Bai; Choi, Jin Young; Park, Won Woong; Jeon, Jun Hong; Won, Sung Ok; Byun, Ji Young; Lim, Sang Ho; Han, Seung Hee

    2010-08-01

    The TiN-coated metal-on-polymer hip prosthetic pair has the potential to reduce wear debris of UHMWPE (ultra-high molecular weight polyethylene) and to prevent metallic-ion-induced cytotoxicity. However, high quality and adherent film is a key to the clinical success of hip prostheses. In this study, titanium nitride (TiN) films were deposited on stainless steel using plasma immersion ion implantation & deposition (PIII&D) technique to create high-quality film and an adherent interface. The chemical state and composition were analyzed by X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES) and energy dispersive spectroscopy (EDS). The mechanical properties of the films were characterized using a micro-hardness tester and a pin-on-disk wear tester, and an x-ray diffractometer (XRD) was used for a crystallographic analysis. The PIII&D-treated TiN films showed a stoichiometric and (200) preferred orientation and micro-hardness up to 150 % higher than untreated film. A TiN-coated specimen using the PIII&D process also showed less UHMWPE wear compared to untreated specimens. The volumetric wear rate of UHMWPE could be reduced by as much as 42 % compared to when Co-Cr alloy was used. The results of this study show that advanced TiN-coating via the PIII&D process is a viable means of reducing UHMWPE wear in the metal-on-polymer bearing couple.

  18. Is the association between hip fractures and seasonality modified by influenza vaccination? An ecological study.

    Science.gov (United States)

    Fraenkel, M; Yitshak-Sade, M; Beacher, L; Carmeli, M; Mandelboim, M; Siris, E; Novack, V

    2017-09-01

    Osteoporotic hip fractures in 4344 patients were more common during winter. Lower temperatures were associated with higher rates of fracture only in those not vaccinated for influenza. Influenza outbreaks increased the risk of hip fractures. Further studies are needed to assess whether influenza vaccination can prevent hip fractures. Winter seasonality of osteoporotic hip fracture incidence has been demonstrated, yet the explanation for the association is lacking. We hypothesize that the seasonality of osteoporotic hip fracture can be explained by an association between hip fractures and seasonal influenza outbreaks. This retrospective cohort study included all patients admitted to Soroka University Medical Center with a diagnosis of osteoporotic hip fracture (ICD-9 code 820) between the years 2001 and 2013. Patients with malignancies, trauma, and age under 50 were excluded. In a time series analysis, we examined the association between hip fracture incidence and seasonality adjusted for meteorological factors, and population rates of influenza infection and vaccination using Poisson models. Four thousand three hundred forty-four patients with a hip fracture were included (69% females, mean age 78). Daily fracture rates were significantly higher in winter (1.1 fractures/day) compared to summer, fall, and spring (0.79, 0.90, and 0.91; p risk only in those not vaccinated for influenza (n = 2939, for every decrease of 5 °C, RR 1.08, CI 1.02-1.16; p risk for hip fracture, adjusted for seasons and temperature, was 1.26 2 weeks following a week with high infection burden (CI 1.05;1.51 p = 0.01), while the temperature was not significantly associated with the fracture risk. Under dry and warm desert climate, winter hip fracture incidence increase might be associated with influenza infection, and this effect can be negated by influenza vaccination.

  19. Plannig strategy for radiotherapic treatment oa patients with prosthetic hip. Solution of intensity; Estrategia para la planificacion de tratamientos radioterapicos de pacientes con protesis de cader. Solucion de intensidad modulada

    Energy Technology Data Exchange (ETDEWEB)

    Puertolas Hernandez, J. R.; Iriondo Igerabide, U.; Lozano Flores, F. J.; Pino Leon, C.; Larretxea Etxarri, R.

    2013-07-01

    The intensity modulated radiation therapy (IMRT) can offer better plans, defining the prosthesis as critical structure that limit the dose. In our case, in the last year we have made five planning hip replacement cases, and one case with two prostheses (bilateral). We are introducing the strategy we use to carry out these planning. (Author)

  20. Clinical Outcomes of Penile Prosthesis Implantation Surgery

    Directory of Open Access Journals (Sweden)

    Onur Dede

    2016-06-01

    Full Text Available Objective: We aimed to evaluating the outcomes of in­flatable penile prosthesis implantations and partner sat­isfaction. Methods: Data of 52 patients who underwent penile prosthesis implantation in single center between May 2010 and December 2015 were retrospectively analyzed. Types of prosthesis, complication and satisfaction rates of patients were recorded by EDITS (Erectile Dysfunction Inventory of Treatment Satisfaction questionnaire was used. Results: The mean age was 49.2±14.7 years for patients. The mean follow-up durations for 34.3±12.5 months. The mean hospital stay was 3.84±1.52 days. Evaluating of the couples satisfaction revealed that 44 (84% of the patient were very satisfied. There was not any complication and no patient need to underwent revision surgery. Conclusion: Inflatable penile prosthesis implants, with high levels of treatment success, patient and partner sat­isfaction, are effective and safe options for treatment of organic erectile dysfunction with acceptable complication and revision rates.

  1. Hearing results using the SMart piston prosthesis.

    Science.gov (United States)

    Fayad, Jose N; Semaan, Maroun T; Meier, Josh C; House, John W

    2009-12-01

    SMart, a newly introduced piston prosthesis for stapedotomy, is a nitinol-based, heat-activated, self-crimping prosthesis. We review our hearing results and postoperative complications using this self-crimped piston prosthesis and compare them with those obtained using stainless steel or platinum piston prostheses. Audiometric results using the SMart piston are identical to those obtained using a conventional piston prosthesis. Retrospective chart review. Private neurotologic tertiary referral center. The 416 ears reviewed included 306 with a SMart prosthesis and 110 conventional prostheses. 61% were women. Mean follow-up time was 5.6 (standard deviation [SD], 6.3 mo) and 6.9 months (SD, 7.0 mo) for the 2 groups, respectively. Stapedotomy using the SMart or a conventional (non-SMart) prosthesis. Audiometric hearing results, including pure-tone average (PTA) and air-bone gap (ABG), and prevalence of postoperative complications. Mean postoperative PTA was 32.6 (SD, 16.8) dB for the SMart group and 29.4 (SD, 13.5) dB for the non-SMart group, with ABGs of 7.6 (SD, 8.9) and 6.0 (SD, 5.2) dB, respectively. Mean change (decrease) in ABG was 18.7 (SD, 13.1) dB for the SMart group and 19.9 (SD, 10.3) dB for the non-SMart group. High-frequency bone PTAs showed overclosure of 2.0 (SD, 7.9) dB for the SMart group and 3.6 (SD, 8.6) dB for the non-SMart group. Postoperative vertigo and tinnitus were infrequent. No significant differences in these audiometric outcomes or complication rates were noted between groups. There was no significant difference in rate of gap closure to within 10 dB (78.3 versus 84.2%, SMart and non-SMart, respectively) or 20 dB (94.2 and 98.0%). Compared with conventional stapes prostheses, the nitinol-based SMart is a safe and reliable stapes prosthesis that eliminates manual crimping without significantly altering the audiometric outcome. Complications are rare, but longer follow-up is needed before establishing long-term stability.

  2. Difficult factors in Management of Impacted Dental Prosthesis in Esophagus

    Directory of Open Access Journals (Sweden)

    Efiaty A. Soepardi

    2005-03-01

    Full Text Available A dental prosthesis which ingested and impacted in esophagus, is an emergency case and life threatening, so require immediate esophagoscopy intervention for removing. The objective of this study is to assess some factors can caused dtfficulties in diagnosing and treating the ingested and impacted dental prosthesis in the esophagus and their complications. This retrospective study analyzed patient’s chart whose underwent esophagoscopy for removing the impacted dental prosthesis in Dr. Cipto Mangunkusumo General Hospital, Jakarta, Indonesia during a period between January 1997 and December 2003. Neck-chest X-ray and esophagoscopy were performed in all patients to identify the existence of the dental prosthesis as a diagnostic and treatment procedure. The length of time for removing the dental prosthesis was recorded and stated as a less difficult esophagoscopy when it takes time less than 60 minutes and as a difficult  esophagoscopy takes 60 minutes or longer. Some risk difficulties factors were statistically analyzed. There were 53 patients of ingested dental prosthesis in esophagus. Only 51 cases were analyzed According to the length of time for removing the dental prosthesis by esophagoscopy, 22 patients were recorded as less difficult cases and 29 patients as difficult cases. Two cases among the cases needed cervicotomy after unsuccessful esophagoscopy removal. The difficulties to diagnose an impacted dental prosthesis in the esophagus caused by unreliable clinical history, unclear signs and symptoms, unable to be detected by X-ray and was not found during esophagoscopy. The difficulties in treating due to mucosal laceration, edema, bleeding, failure of the first extraction and conformity with the size and shape, the wire outside the dental prosthesis and the length of time stayed in the esophagus. (Med J Indones 2005; 14: 33-6Keywords: ingested dental prosthesis, radioluscent foreign body, length of time of esophagoscopy

  3. Impact of aortic prosthesis-patient mismatch on left ventricular mass regression.

    Science.gov (United States)

    Alassal, Mohamed A; Ibrahim, Bedir M; Elsadeck, Nabil

    2014-06-01

    Prostheses used for aortic valve replacement may be small in relation to body size, causing prosthesis-patient mismatch and delaying left ventricular mass regression. This study examined the effect of prosthesis-patient mismatch on regression of left ventricular mass after aortic valve replacement. We prospectively studied 96 patients undergoing aortic valve replacement between 2007 and 2012. Mean and peak gradients and indexed effective orifice area were measured by transthoracic echocardiography at 3 and 6 months postoperatively. Patient-prosthesis mismatch was defined as indexed effective orifice area ≤0.85 cm(2)·m(-2). Moderate prosthesis-patient mismatch was present in 25% of patients. There were no significant differences in demographic and operative data between patients with and without prosthesis-patient mismatch. Left ventricular dimensions, posterior wall thickness, transvalvular gradients, and left ventricular mass decreased significantly after aortic valve replacement in both groups. The interventricular septal diameter and left ventricular mass index regression, and left ventricular ejection fraction were better in patients without prosthesis-patient mismatch. There was a significant positive correlation between the postoperative indexed effective orifice area of each valve prosthesis and the rate of left ventricular mass regression. Prosthesis-patient mismatch leads to higher transprosthetic gradients and impaired left ventricular mass regression. A small-sized valve prosthesis does not necessarily result in prosthesis-patient mismatch, and may be perfectly adequate in patient with small body size. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  4. [The endo-exo prosthesis for patients with a problematic amputation stump].

    Science.gov (United States)

    Frölke, Jan Paul M; van de Meent, Henk

    2010-01-01

    Following lower limb amputation, quality of life is highly related to the ability to use a prosthetic limb. The conventional way to attach a prosthetic limb to the body is with a socket. Many patients experience serious discomfort wearing a conventional prosthesis because of pain, instability during walking, pressure sores, bad smell or skin irritation. In addition, sitting is uncomfortable and pelvic and lower back pain due to unstable gait is often seen in these patients. The main disadvantage of the current prosthesis is the attachment of a rigid prosthesis socket to a soft and variable body. The socket must fit tightly for stability during walking but should also be comfortable for sitting. The implantation of an osseointegrated, intramedullary, transcutaneously conducted prosthesis is a new procedure for attaching a limb prosthesis to the human body without the disadvantages of the conventional prosthesis. The intramedullary prosthesis is designed with a rough surface resembling cancellous bone to enable a secure solid integration with the long bone. We treated two patients with this new prosthesis, a 44-year-old man after a transfemoral amputation, and a 32-year-old woman after a lower leg amputation; both amputations were necessary because of trauma. Those two patients are now, more than one year after the operation, showing excellent functional results without infectious complications. We assume that endo-exo prosthesis may be a promising option for selected patients unable to use a conventional prosthesis because of a problematic amputation stump.

  5. [Microbiological characteristics and patterns of resistance in prosthetic joint infections in a referral hospital].

    Science.gov (United States)

    Ortega-Peña, Silvestre; Colín-Castro, Claudia; Hernández-Duran, Melissa; López-Jácome, Esaú; Franco-Cendejas, Rafael

    2015-01-01

    The prosthetic joint infection is the most feared and catastrophic complication for cause severe physical damage to patients and, generates high economic costs. To describe the microbiological characteristics and to determine the resistance pattern in prosthetic joint infections in a reference hospital in Mexico. Patients whose prosthetic devices were withdrawn due to suspicion of septic and aseptic loosening were included. Cultures were performed to identify microorganisms and susceptibility analysis. Of the 111 patients included, 55% were diagnosed with prosthetic joint infection, with the most frequent prosthesis being of the hip (43%). Positive cultures were obtained in 97% of the infected cases, of which 75% were monomicrobial infections. The most frequent bacterial species isolated were: Staphylococcus epidermidis (31%), Enterococcus faecalis (16%), Staphylococcus aureus (13%), and Escherichia coli (8%). The resistance patterns for the Staphylococcus genus were: oxacillin (79%), erythromycin (45%) and ciprofloxacin (37%). Enterococcus faecalis showed a high percentage of resistance to erythromycin and clindamycin (86%), and fluoroquinolones (43%). The large majority (86%) of Escherichia coli were extended spectrum beta-lactamases positive, in addition to having high resistance to fluoroquinolones (86%), trimethoprim/sulfamethoxazole (86%) and gentamicin (72%). The microbiological characteristics found in prosthetic joint infections vary according to the hospitals. In this series, a high proportion of coagulase-negative Staphylococci and Enterococcus spp. were found, as well as a high bacterial resistance. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  6. Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis

    Directory of Open Access Journals (Sweden)

    Luis M Astudillo

    2012-01-01

    Full Text Available OBJECTIVE: We sought to ascertain predictors of Patient Prosthesis Mismatch, an independent predictor of mortality, in patients with aortic stenosis using bioprosthetic valves. METHOD: We analyzed 2,107 sequential surgeries. Patient Prosthesis Mismatch was calculated using the effective orifice area of the prosthesis divided by the patient's body surface area. We defined nonsignificant, moderate, and severe Patient Prosthesis Mismatch as effective orifice area indexes of .0.85 cm²/m, 0.85-0.66 cm²/m², and <0.65 cm²/m², respectively. RESULTS: A total of 311 bioprosthetic patients were identified. The incidence of nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 41%, 42, and 16%, respectively. Severe Patient Prosthesis Mismatch was significantly more prevalent in females (82%. In severe Patient Prosthesis Mismatch, the perfusion and the crossclamp times were considerably lower when compared with nonsignificant Patient Prosthesis Mismatch and moderate Patient Prosthesis Mismatch. Patients with severe Patient Prosthesis Mismatch had a significantly higher likelihood of spending time in the intensive care unit and a significantly longer length of stay in the hospital. Body surface area was not different in severe Patient Prosthesis Mismatch when compared with nonsignificant Patient Prosthesis Mismatch. In-hospital mortality in patients with nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 2.3%, 6.1%, and 8%, respectively. Minimally invasive surgery was significantly associated with moderate Patient Prosthesis Mismatch in 49% of the patients, but not with severe Patient Prosthesis Mismatch. CONCLUSION: Severe Patient Prosthesis Mismatch is more common in females, but not in those with minimal available body surface area. Though operative times were shorter in these patients, intensive care unit and hospital lengths of stay were longer. Surgeons and cardiologists should be cognizant of these clinical

  7. Hip dysplasia and congenital hip dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Lingg, G.; Nebel, G.; von Torklus, D.

    1981-11-01

    In human genetics and orthopedics quite different answers have been given to the question of hereditary transmission and frequency of hip dysplasia in families of children with congenital hip dislocation. We therefore have made roentgenometric measurements of 110 parents of children with congenital hip dislocation. In 25% we found abnormal flat acetabulae, whereas 12% had pathologic deep hips. This may propose a new concept of morphology of congenital hip dysplasia.

  8. Hip arthroscopy versus open surgical dislocation for femoroacetabular impingement

    Science.gov (United States)

    Zhang, Dagang; Chen, Long; Wang, Guanglin

    2016-01-01

    Abstract Background: This meta-analysis aims to evaluate the efficacy and safety of hip arthroscopy versus open surgical dislocation for treating femoroacetabular impingement (FAI) through published clinical trials. Methods: We conducted a comprehensive literature search using PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials databases for relevant studies on hip arthroscopy and open surgical dislocation as treatment options for FAI. Results: Compared with open surgical dislocation, hip arthroscopy resulted in significantly higher Nonarthritic Hip Scores (NAHS) at 3- and 12-month follow-ups, a significant improvement in NAHS from preoperation to 3 months postoperation, and a significantly lower reoperation rate. Open surgical dislocation resulted in a significantly improved alpha angle by the Dunn view in patients with cam osteoplasty from preoperation to postoperation, compared with hip arthroscopy. This meta-analysis demonstrated no significant differences in the modified Harris Hip Score, Hip Outcome Score-Activities of Daily Living, or Hip Outcome Score-Sport Specific Subscale at 12 months of follow-up, or in complications (including nerve damage, wound infection, and wound dehiscence). Conclusion: Hip arthroscopy resulted in higher NAHS and lower reoperation rates, but had less improvement in alpha angle in patients with cam osteoplasty, than open surgical dislocation. PMID:27741133

  9. LEUKOCYTE AND BACTERIA IMAGING IN PROSTHETIC JOINT INFECTION

    NARCIS (Netherlands)

    Glaudemans, Andor W. J. M.; Galli, Filippo; Pacilio, Marta; Signore, Alberto

    2013-01-01

    There has been a significant increase in the number of joint prosthesis replacements worldwide. Although relatively uncommon, complications can occur with the most serious being an infection. Various radiological and nuclear imaging techniques are available to diagnose prosthetic joint infections

  10. Release of Gentamicin and Vancomycin from Preformed Spacers in Infected Total Hip Arthroplasties: Measurement of Concentrations and Inhibitory Activity in Patients’ Drainage Fluids and Serum

    Directory of Open Access Journals (Sweden)

    Dario Regis

    2013-01-01

    Full Text Available Gentamicin (G and vancomycin (V concentrations in drainage fluids obtained from patients during the first 24 hours after implantation of antibiotic-loaded polymethylmethacrylate (PMMA spacers in two-stage revision of infected total hip arthroplasty were studied. The inhibitory activity of drainage fluids against different multiresistant clinical isolates was investigated as well. Seven hips were treated by implantation of industrial G-loaded spacers. Vancomycin was added by manually mixing with PMMA bone cement. Serum and drainage fluid samples were collected 1, 4, and 24 hours after spacer implantation. Antibiotics concentrations and drains bactericidal titer of combination were determined against multiresistant staphylococcal strains. The release of G and V from PMMA cement at the site of infection was prompt and effective. Serum levels were below the limit of detection. The local release kinetics of G and V from PMMA cement was similar, exerting a pronounced, combined inhibitory effect in the implant site. The inhibitory activity of drainage fluids showed substantial intersubject variability related to antibiotic concentrations and differed according to the pathogens tested. Gentamicin and vancomycin were released from temporary hip spacers at bactericidal concentrations, and their use in combination exerted strong inhibition against methicillin-resistant S. aureus and Coagulase Negative Staphylococci strains.

  11. Fatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Rinne M. Peters

    2017-01-01

    Full Text Available This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA. After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year postoperatively, X-rays and MARS-MRI showed a fixed reversed hybrid THA, with periarticular densities, flattening of the femoral head component, and a pattern of periarticular metal wear debris and pseudotumor formation. Before revision could take place, the patient was admitted with the clinical picture of systemic cobalt toxicity, supported by excessively high serum cobalt and chromium levels, and ultimately died. At autopsy dilated cardiomyopathy as cause of death was hypothesized. A third body wear reaction between ceramic remnants and the metal femoral head very likely led to excessive metal wear, which contributed systemic cobalt toxicity leading to neurotoxicity and heart failure. This case emphasizes that fractured ceramic-on-ceramic bearings should be revised to ceramic-on-ceramic or ceramic-on-polyethylene bearings, but not to metal-on-polyethylene bearings. We aim to increase awareness among orthopedic surgeons for clinical clues for systemic cobalt intoxication, even when there is no metal-on-metal bearing surface.

  12. Intermittent, noncyclic dysfunction of a mechanical aortic prosthesis by pannus formation.

    Science.gov (United States)

    Giroux, Sylvie K; Labinaz, Marino X; Grisoli, Dominique; Klug, Andrew P; Veinot, John P; Burwash, Ian G

    2010-01-01

    Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. Pannus formation usually restricts systolic excursion of the occluding disk, resulting in progressive stenosis of the aortic prosthesis. Intermittent dysfunction of a mechanical aortic prosthesis is usually ascribed to thrombus formation. We describe an unusual case of intermittent, noncyclic dysfunction of a mechanical aortic prosthesis due to pannus formation in the absence of systolic restriction of disk excursion that presented with intermittent massive aortic regurgitation, severe ischemia, and shock. Pannus formation should be considered as a potential cause of acute intermittent severe aortic regurgitation in a patient with a mechanical aortic prosthesis.

  13. Differential contributions of specimen types, culturing, and 16S rRNA sequencing in diagnosis of prosthetic joint infections

    DEFF Research Database (Denmark)

    Larsen, Lone Heimann; Khalid, Vesal; Xu, Yijuan

    2018-01-01

    to variations in specimen sampling. In this prospective, multidisciplinary study of hip or knee prosthetic failures, we assessed the contributions of different specimen types, extended culture incubations, and 16S rRNA sequencing for diagnosing prosthetic joint infections (PJI). Project specimens included joint...... fluid (JF), bone biopsy specimens (BB), soft-tissue biopsy specimens (STB), and swabs (SW) from the prosthesis, collected in situ, and sonication fluid collected from prosthetic components (PC). Specimens were cultured for 6 (conventional) or 14 days, and 16S rRNA sequencing was performed at study...... completion. Of the 156 patients enrolled, 111 underwent 114 surgical revisions (cases) due to indications of either PJI (n = 43) or AF (n = 71). Conventional tissue biopsy cultures confirmed PJI in 28/43 (65%) cases and refuted AF in 3/71 (4%) cases; one case was not evaluable. Based on these results, minor...

  14. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  15. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  16. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  17. HPLC/DAD Intercomparison on Phytoplankton Pigments (HIP-1, HIP-2, HIP-3 and HIP-4)

    OpenAIRE

    CANUTI Elisabetta; RAS Josephine; GRUNG Merete; ROTTGERS Rudiger; COSTA GOELA Priscilla; ARTUSO Florinda; CATALDI Dario

    2016-01-01

    From 2009 to 2015, in the context of the MERIS (Medium Resolution Imaging Spectrometer) validation activities, the JRC Marine Optical Laboratory organised four HPLC Intercomparison exercises for Phytoplankton Pigment measurements (HIP-1, HIP-2, HIP-3 and HIP-4), involving seven European accredited and reference laboratories. The objectives of these intercomparison exercises were: creating a reference community at European level for phytoplankton pigment analysis capable of supporting satel...

  18. Accelerated avascular necrosis after single intra-articular injection of corticosteroid into the hip joint

    OpenAIRE

    Kassam, A M

    2010-01-01

    Avascular necrosis (AVN) involves destruction of the hip joint. Long-term use of steroids has been shown to cause AVN. This article presents a case of intra-articular injection of steroid causing a rapid onset of AVN in the hip joint. Bone histology at time of total hip replacement showed evidence of AVN and no evidence of infection.

  19. A modified technique for retention of orbital prosthesis

    Directory of Open Access Journals (Sweden)

    Sameera R Shaikh

    2011-01-01

    Full Text Available An orbital defect (congenital or acquired causes severe facial asymmetry and disfigurement, which results in psychological and social disturbances to the patient. It becomes a challenging task for a maxillofacial prosthodontist to fabricate a prosthesis that replicates the healthy side of the face. Success of the prosthesis depends primarily on satisfactory retention of the same. This clinical report illustrates rehabilitation of a patient with an orbital defect by fabricating a hollow orbital prosthesis, utilizing anatomical undercuts for retention using an acrylic resin template relined by a resilient denture liner.

  20. Infections in orthopaedic surgery : clinical and experimental studies

    NARCIS (Netherlands)

    Vogely, Henri Charles

    2000-01-01

    The diagnostic difficulties, variability in outcome and the heterogeinity of the problem of orthopaedic infections stimulated the author to a study of the literature, and several clinical and experimental studies. The diagnosis prosthesis-related infection can only be reached with an acceptable

  1. Communication Protocol for Advanced Prosthesis Components

    OpenAIRE

    Karnå, David

    2007-01-01

    It would be of great value for the prosthesis industry to achieve an open standard for communication in upper limb prostheses. Cooperation between NTNU and the University of New Brunswick has resulted in a functional requirements specification for such a standard, SCIP(Standardised Communication Interface in Prostheses). The special challenges for communication in a prosthesis system are possible noisy environments, high demands for light weight, safety for the user and the fact that devices ...

  2. Noncontact tomography and a pH-sensitive nanocomposite for monitoring osseointegrated prosthesis interfaces

    Science.gov (United States)

    Gupta, Sumit; Loh, Kenneth J.

    2017-04-01

    The main objective of this research is to develop a noncontact and noninvasive method for monitoring infections at the interface of human tissue and osseointegrated prostheses. The technique used here is centered on the theory of a noncontact permittivity imaging technique known as electrical capacitance tomography (ECT). This work is divided into two main parts. First, an ECT electrical permittivity reconstruction software and hardware system was developed. Second, a carbon nanotube-polyaniline nanocomposite thin film was designed and fabricated such that its electrical permittivity is sensitive to pH stimuli. The dielectric properties of this thin film were characterized as it was exposed to different pH buffer solutions. It is envisioned that osseointegrated implants can be pre-coated with the pH-sensitive nanocomposite prior to implant. When infection occurs and alters the local pH of tissue at the human-prosthesis interface, the dielectric property of the film would change accordingly. Then, ECT can interrogate the cross-section of the human limb and reconstruct its permittivity distribution, revealing localized changes in permittivity due to infection. To validate this concept, a prosthesis phantom was coated with the nanocomposite pH sensor and then immersed in different pH buffer solutions. ECT was conducted, and the results showed that the magnitude and location of subsurface, localized, pH changes could be detected. In general, noncontact tomography coupled with stimuliresponsive thin films could pave way for new modalities of noninvasive human body imaging, in particular, for patients with osseointegrated implants and prostheses.

  3. Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis 5-year follow-up of 52 patients

    DEFF Research Database (Denmark)

    Gustafson, Klas; Jakobsen, Stig S; Lorenzen, Nina D

    2014-01-01

    to an increased incidence of metal allergy. METHODS: 52 hips in 52 patients (median age 60 (51-64) years, 30 women) were randomized to either a MOM hip resurfacing system (ReCap) or a standard MOP total hip arthoplasty (Mallory Head/Exeter). Spot urine samples were collected preoperatively, postoperatively, after....... RESULTS: A statistically significant 10- to 20-fold increase in urinary levels of cobalt and chromium was observed throughout the entire follow-up in the MOM group. The prevalence of metal allergy was similar between groups. INTERPRETATION: While we observed significantly increased levels of metal ions...

  4. Fabrication of a Cranial Prosthesis Combined with an Ocular Prosthesis Using Rapid Prototyping: A Case Report

    Directory of Open Access Journals (Sweden)

    Gayatri Shankaran

    2016-08-01

    Full Text Available Rapid prototyping (RP is a technique of manufacturing parts by the additive layer manufacturing technology; where, a three-dimensional (3D model created in a computer aided design (CAD system is sectioned into 2D profiles, which are further constructed by RP layer by layer. Its use is not limited to industrial or engineering fields and has extended to the medical field for the manufacturing of custom implants and prostheses, the study of anatomy and surgical planning. Nowadays, dentists are more frequently encountered with the individuals affected with craniofacial defects due to trauma. In such cases, the cranio-maxillofacial rehabilitation is a real challenge to bring the patients back to society and promote their well-being. The conventional impression technique for facial prosthesis fabrication has the disadvantage of deforming the soft tissue and causing discomfort for the patient. Herein, we describe the fabrication of a cranial prosthesis combined with an ocular prosthesis with RP and stereolithography.

  5. Fabrication of a Cranial Prosthesis Combined with an Ocular Prosthesis Using Rapid Prototyping: A Case Report.

    Science.gov (United States)

    Shankaran, Gayatri; Deogade, Suryakant Chhagan; Dhirawani, Rajesh

    2016-01-01

    Rapid prototyping (RP) is a technique of manufacturing parts by the additive layer manufacturing technology; where, a three-dimensional (3D) model created in a computer aided design (CAD) system is sectioned into 2D profiles, which are further constructed by RP layer by layer. Its use is not limited to industrial or engineering fields and has extended to the medical field for the manufacturing of custom implants and prostheses, the study of anatomy and surgical planning. Nowadays, dentists are more frequently encountered with the individuals affected with craniofacial defects due to trauma. In such cases, the craniomaxillofacial rehabilitation is a real challenge to bring the patients back to society and promote their well-being. The conventional impression technique for facial prosthesis fabrication has the disadvantage of deforming the soft tissue and causing discomfort for the patient. Herein, we describe the fabrication of a cranial prosthesis combined with an ocular prosthesis with RP and stereolithography.

  6. TOTAL HIP ARTHROPLASTY IN CHILDREN WHO HAVE UNDERGONE ARTHROPLASTY WITH DEMINERALIZED BONE-CARTILAGE ALLOCUPS

    Directory of Open Access Journals (Sweden)

    Vladimir E. Baskov

    2017-03-01

    hip replacement surgery. Conclusions. The main feature of the implementation of total hip replacement, following a previous intervention involving arthroplasty with DBCA, was a pronounced deficit of the pelvic bone in the joint component. This significantly complicated the subsequent implantation of the acetabular prosthesis component, and in some cases required the use of a cemented acetabular component. Our experience suggests that patients under 11 years of age who show clinical and radiological signs of coxarthrosis can be treated with arthroplasty with DBCA in order to save the lost function of the hip joint and maintain the function of the periarticular muscles.

  7. Total hip arthroplasty in children who have undergone arthroplasty with demineralized bone-cartilage allocups

    Directory of Open Access Journals (Sweden)

    Vladimir E. Baskov

    2017-03-01

    hip replacement surgery. Conclusions. The main feature of the implementation of total hip replacement, following a previous intervention involving arthroplasty with DBCA, was a pronounced deficit of the pelvic bone in the joint component. This significantly complicated the subsequent implantation of the acetabular prosthesis component, and in some cases required the use of a cemented acetabular component. Our experience suggests that patients under 11 years of age who show clinical and radiological signs of coxarthrosis can be treated with arthroplasty with DBCA in order to save the lost function of the hip joint and maintain the function of the periarticular muscles.

  8. Metabolics of stair ascent with a powered transfemoral prosthesis.

    Science.gov (United States)

    Ledoux, E D; Lawson, B E; Shultz, A H; Bartlett, H L; Goldfarb, M

    2015-01-01

    This paper evaluates the effectiveness of a powered knee and ankle prosthesis for stair ascent through a metabolic assessment comparing energy expenditure of a single transfemoral amputee subject while ascending stairs with the powered prosthesis relative to his passive daily use device, as well as comparing the kinematics and kinetics obtained with the passive prosthesis to healthy biomechanics. The subject wore a portable system that measured pulmonary gaseous exchange rates of oxygen and carbon dioxide while he ascended stairs with each of the prostheses in alternating tests. The results indicated that the amputee's energy expenditure decreased by 32 percent while climbing with the powered prosthesis as compared to his passive one, and the kinematics and kinetics achieved were representative of healthy biomechanics.

  9. Managing uncertainty - a qualitative study of surgeons' decision-making for one-stage and two-stage revision surgery for prosthetic hip joint infection.

    Science.gov (United States)

    Moore, Andrew J; Blom, Ashley W; Whitehouse, Michael R; Gooberman-Hill, Rachael

    2017-04-12

    Approximately 88,000 primary hip replacements are performed in England and Wales each year. Around 1% go on to develop deep prosthetic joint infection. Between one-stage and two-stage revision arthroplasty best treatment options remain unclear. Our aims were to characterise consultant orthopaedic surgeons' decisions about performing either one-stage or two-stage revision surgery for patients with deep prosthetic infection (PJI) after hip arthroplasty, and to identify whether a randomised trial comparing one-stage with two-stage revision would be feasible. Semi-structured interviews were conducted with 12 consultant surgeons who perform revision surgery for PJI after hip arthroplasty at 5 high-volume National Health Service (NHS) orthopaedic departments in England and Wales. Surgeons were interviewed before the development of a multicentre randomised controlled trial. Data were analysed using a thematic approach. There is no single standardised surgical intervention for the treatment of PJI. Surgeons balance multiple factors when choosing a surgical strategy which include multiple patient-related factors, their own knowledge and expertise, available infrastructure and the infecting organism. Surgeons questioned whether it was appropriate that the two-stage revision remained the best treatment, and some surgeons' willingness to consider more one-stage revisions had increased over recent years and were influenced by growing evidence showing equivalence between surgical techniques, and local observations of successful one-stage revisions. Custom-made articulating spacers was a practice that enabled uncertainty to be managed in the absence of definitive evidence about the superiority of one surgical technique over the other. Surgeons highlighted the need for research evidence to inform practice and thought that a randomised trial to compare treatments was needed. Most surgeons thought that patients who they treated would be eligible for trial participation in instances

  10. Orthostatic intolerance during early mobilization after fast-track hip arthroplasty

    DEFF Research Database (Denmark)

    Jans, O; Bundgaard-Nielsen, M; Solgaard, S

    2012-01-01

    has not been established after THA. This study evaluated the cardiovascular response and tissue oxygenation to mobilization before and after surgery in relation to OI in fast-track THA patients. METHODS: /st>OI and the cardiovascular response to standing were evaluated with a standardized mobilization......BACKGROUND: /st>Early postoperative mobilization is a cornerstone in fast-track total hip arthroplasty (THA), but postoperative orthostatic intolerance (OI) may delay early recovery or lead to fainting, falls, and prosthesis dislocation or fracture. However, the prevalence and pathophysiology of OI...... protocol, before, 6, and 24 h after surgery in 26 patients undergoing THA with spinal anaesthesia and an opioid-sparing analgesic regime. Haemoglobin, fluid balance, and opioid use were recorded. Systolic (SAP) and diastolic (DAP) arterial pressure, heart rate (HR), stroke volume (SV), cardiac output (CO...

  11. Hip Resurfacing: An Alternative to Conventional Hip Replacement?

    Science.gov (United States)

    ... Is hip resurfacing a good alternative to hip replacement? Answers from Mark Spangehl, M.D. Hip resurfacing has lost favor with many surgeons ... women with poor bone quality. Unlike traditional hip replacement, hip resurfacing doesn't completely replace the "ball" ...

  12. Optimization of scan time in MRI for total hip prostheses. SEMAC tailoring for prosthetic implants containing different types of metals

    Energy Technology Data Exchange (ETDEWEB)

    Deligianni, X. [University of Basel Hospital, Basel (Switzerland). Div. of Radiological Physics; Merian Iselin Klinik, Basel (Switzerland). Inst. of Radiology; Bieri, O. [University of Basel Hospital, Basel (Switzerland). Div. of Radiological Physics; Elke, R. [Orthomerian, Basel (Switzerland); Wischer, T.; Egelhof, T. [Merian Iselin Klinik, Basel (Switzerland). Inst. of Radiology

    2015-12-15

    Magnetic resonance imaging (MRI) of soft tissues after total hip arthroplasty is of clinical interest for the diagnosis of various pathologies that are usually invisible with other imaging modalities. As a result, considerable effort has been put into the development of metal artifact reduction MRI strategies, such as slice encoding for metal artifact correction (SEMAC). Generally, the degree of metal artifact reduction with SEMAC directly relates to the overall time spent for acquisition, but there is no specific consensus about the most efficient sequence setup depending on the implant material. The aim of this article is to suggest material-tailored SEMAC protocol settings. Five of the most common total hip prostheses (1. Revision prosthesis (S-Rom), 2. Titanium alloy, 3. Mueller type (CoNiCRMo alloy), 4. Old Charnley prosthesis (Exeter/Stryker), 5. MS-30 stem (stainless-steel)) were scanned on a 1.5 T MRI clinical scanner with a SEMAC sequence with a range of artifact-resolving slice encoding steps (SES: 2 - 23) along the slice direction (yielding a total variable scan time ranging from 1 to 10 min). The reduction of the artifact volume in comparison with maximal artifact suppression was evaluated both quantitatively and qualitatively in order to establish a recommended number of steps for each case. The number of SES that reduced the artifact volume below approximately 300 mm{sup 3} ranged from 3 to 13, depending on the material. Our results showed that although 3 SES steps can be sufficient for artifact reduction for titanium prostheses, at least 11 SES should be used for prostheses made of materials such as certain alloys of stainless steel. Tailoring SES to the implant material and to the desired degree of metal artifact reduction represents a simple tool for workflow optimization of SEMAC imaging near total hip arthroplasty in a clinical setting.

  13. Optimization of scan time in MRI for total hip prostheses. SEMAC tailoring for prosthetic implants containing different types of metals

    International Nuclear Information System (INIS)

    Deligianni, X.; Wischer, T.; Egelhof, T.

    2015-01-01

    Magnetic resonance imaging (MRI) of soft tissues after total hip arthroplasty is of clinical interest for the diagnosis of various pathologies that are usually invisible with other imaging modalities. As a result, considerable effort has been put into the development of metal artifact reduction MRI strategies, such as slice encoding for metal artifact correction (SEMAC). Generally, the degree of metal artifact reduction with SEMAC directly relates to the overall time spent for acquisition, but there is no specific consensus about the most efficient sequence setup depending on the implant material. The aim of this article is to suggest material-tailored SEMAC protocol settings. Five of the most common total hip prostheses (1. Revision prosthesis (S-Rom), 2. Titanium alloy, 3. Mueller type (CoNiCRMo alloy), 4. Old Charnley prosthesis (Exeter/Stryker), 5. MS-30 stem (stainless-steel)) were scanned on a 1.5 T MRI clinical scanner with a SEMAC sequence with a range of artifact-resolving slice encoding steps (SES: 2 - 23) along the slice direction (yielding a total variable scan time ranging from 1 to 10 min). The reduction of the artifact volume in comparison with maximal artifact suppression was evaluated both quantitatively and qualitatively in order to establish a recommended number of steps for each case. The number of SES that reduced the artifact volume below approximately 300 mm 3 ranged from 3 to 13, depending on the material. Our results showed that although 3 SES steps can be sufficient for artifact reduction for titanium prostheses, at least 11 SES should be used for prostheses made of materials such as certain alloys of stainless steel. Tailoring SES to the implant material and to the desired degree of metal artifact reduction represents a simple tool for workflow optimization of SEMAC imaging near total hip arthroplasty in a clinical setting.

  14. Penile prosthesis implant: scientific advances and technological innovations over the last four decades.

    Science.gov (United States)

    Chung, Eric

    2017-02-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades.

  15. Cemented hemi-arthroplasty in proximal femoral fractures in elderly with severe osteoporosis: A case series

    Directory of Open Access Journals (Sweden)

    Rahul M Salunkhe

    2012-01-01

    Full Text Available Context: Inter-trochanteric fractures in osteoporotic bones which are grossly comminuted are highly unstable and difficult to treat. Conservative treatment with traction and prolonged immobilization lands up with many complications and often fatality. Rate of failure with internal fixation with dynamic hip screw has been found to be high, especially in osteoporotic bones. Revision osteo-synthesis is technically demanding and leads to complications. Aim: To assess the efficacy of cemented hemiarthroplasty in the management of proximal femoral fractures in elderly patients with severe osteoporosis. Settings and Design: A Case series of 50 cases. Materials and Methods: We divided these fractures into three groups and accordingly the prosthesis was used. Group 1- intact calcar and lesser trochanter non-communited-AMP type of bipolar prosthesis, Group 2- fracture of calcar - Thompson′s type of bipolar prosthesis with calcar reconstruction, Group 3- group 2 + instability of postero-medial wall-modular type bipolar prosthesis with lesser trochanter and calcar reconstruction. Greater trochanter, calcar, and lesser trochanter were reconstructed with encirclage, tension band wiring, fashioned bone graft, or bone cement collar accordingly. Results: In our study of 50 cases with mean age 79.57 years, 20 cases were type 1, 19 type 2, and 11 type 3 fractures. The average Harris hip score was 79. Excellent to fair results were obtained at follow-up in 46 (92% and in 4 (8% results were poor. The mean Harris hip score was 83 (good in Group- I, 79 (Fair in Group- II, and 72 (Fair in Group- III patients. Average hospital stay was 12.5 days. There were four cases of superficial operative site infection which were treated with short course of oral antibiotics. Four cases died of medical complications, earliest being 3 months, and latest being 18 months. No case of loosening of the prosthesis, break in the cement or sinking of prosthesis was seen.

  16. Two-stage revision of septic knee prosthesis with articulating knee spacers yields better infection eradication rate than one-stage or two-stage revision with static spacers.

    Science.gov (United States)

    Romanò, C L; Gala, L; Logoluso, N; Romanò, D; Drago, L

    2012-12-01

    The best method for treating chronic periprosthetic knee infection remains controversial. Randomized, comparative studies on treatment modalities are lacking. This systematic review of the literature compares the infection eradication rate after two-stage versus one-stage revision and static versus articulating spacers in two-stage procedures. We reviewed full-text papers and those with an abstract in English published from 1966 through 2011 that reported the success rate of infection eradication after one-stage or two-stage revision with two different types of spacers. In all, 6 original articles reporting the results after one-stage knee exchange arthoplasty (n = 204) and 38 papers reporting on two-stage revision (n = 1,421) were reviewed. The average success rate in the eradication of infection was 89.8% after a two-stage revision and 81.9% after a one-stage procedure at a mean follow-up of 44.7 and 40.7 months, respectively. The average infection eradication rate after a two-stage procedure was slightly, although significantly, higher when an articulating spacer rather than a static spacer was used (91.2 versus 87%). The methodological limitations of this study and the heterogeneous material in the studies reviewed notwithstanding, this systematic review shows that, on average, a two-stage procedure is associated with a higher rate of eradication of infection than one-stage revision for septic knee prosthesis and that articulating spacers are associated with a lower recurrence of infection than static spacers at a comparable mean duration of follow-up. IV.

  17. Availability of Dental Prosthesis Procedures in Brazilian Primary Health Care

    Directory of Open Access Journals (Sweden)

    Maria Aparecida Gonçalves Melo Cunha

    2018-01-01

    Full Text Available Objectives. To describe dental prosthesis provision in the Brazilian public health service and report the performance of dental prosthesis procedures according to the Brazilian macroregions. Methods. A structured interview was conducted with senior-level health professionals from each of the 18,114 oral health teams (OHT. The dependent variables were performance of removable prostheses and prosthesis procedures, including provision of fixed prostheses by OHT. Descriptive statistics were produced together with performing a cluster analysis using SPSS version 19.0. Results. The manufacture of any type of prosthesis was done by a minority of OHT (43%. The most commonly provided types of dental prosthesis were removable full and partial dentures. Cluster 1 (teams that performed prosthesis procedures the most was composed of a smaller number of teams (n = 5,531, and Cluster 2 (composed of teams that do not perform prosthetics or that perform them in small amounts consisted of 12,583 teams. The geographic distribution of clusters reveals that the largest proportion of Cluster 1 teams is located in the Northeast (33.9% and Southeast (33.6%. Conclusions. A minority of OHT produce dental prostheses. There is an unequal geographical distribution of clusters.

  18. Amputation and prosthesis implantation shape body and peripersonal space representations.

    Science.gov (United States)

    Canzoneri, Elisa; Marzolla, Marilena; Amoresano, Amedeo; Verni, Gennaro; Serino, Andrea

    2013-10-03

    Little is known about whether and how multimodal representations of the body (BRs) and of the space around the body (Peripersonal Space, PPS) adapt to amputation and prosthesis implantation. In order to investigate this issue, we tested BR in a group of upper limb amputees by means of a tactile distance perception task and PPS by means of an audio-tactile interaction task. Subjects performed the tasks with stimulation either on the healthy limb or the stump of the amputated limb, while wearing or not wearing their prosthesis. When patients performed the tasks on the amputated limb, without the prosthesis, the perception of arm length shrank, with a concurrent shift of PPS boundaries towards the stump. Conversely, wearing the prosthesis increased the perceived length of the stump and extended the PPS boundaries so as to include the prosthetic hand, such that the prosthesis partially replaced the missing limb.

  19. Late septic hip dislocation with multifocal osteomyelitis and malaria: a case report.

    Science.gov (United States)

    Sreenivas, T; Menon, Jagdish; Nataraj, A R

    2012-12-01

    A 9-year-old boy presented with high-grade fever associated with pain and swelling in right hip and left leg of 1-week duration. Pus was found on diagnostic aspiration of the right hip joint. Emergency arthrotomy was performed through anterior approach with drill holes in proximal femur and culture showed MRSA. Intravenous antibiotics were given for 4 weeks. Patient symptomatically improved in immediate postoperative period and in bed hip mobilization was started. On eighth postoperative day, child developed high-grade intermittent fever with chills and rigors and diagnosed as plasmodium falciparum malaria. Fever subsided with antimalarial treatment. On twenty-first day, patient complained pain in right hip and X-ray showed posterior hip dislocation with osteomyelitis of proximal femur. Closed reduction and hip spica application was done under general anesthesia. At follow-up, the clinical result was fair with resolution of infection and stiff hip.

  20. New-Onset Depression Following Hip Fracture Is Associated With Increased Length of Stay in Hospital and Rehabilitation Centers

    Directory of Open Access Journals (Sweden)

    Anna C. Phillips

    2015-05-01

    Full Text Available This article examines the coincident effects of new-onset depression post hip fracture on length of hospital stay, readmission rates, and incidence of infections in older adults. Participants were 101 hip fracture patients aged 60+ years; 38 developed depressive symptoms following their fracture. Infection rates, readmissions to hospital and rehabilitation units, and length of hospital stay were assessed over the 6 months post hip fracture from hospital and general practitioner notes. Patients who developed depression by Week 6 post fracture were likely to spend more time in hospital/rehabilitation wards (p = .02 and more likely to be discharged to a rehabilitation unit (p < .05. There were no group differences in readmissions or infection rates. New-onset depression coincident with hip fracture in older adults is associated with longer hospital ward stays and greater need for rehabilitation.

  1. Posterosuperior Placement of a Standard-Sized Cup at the True Acetabulum in Acetabular Reconstruction of Developmental Dysplasia of the Hip With High Dislocation.

    Science.gov (United States)

    Xu, Jiawei; Xu, Chen; Mao, Yuanqing; Zhang, Jincheng; Li, Huiwu; Zhu, Zhenan

    2016-06-01

    We sought to evaluate posterosuperior placement of the acetabular component at the true acetabulum during acetabular reconstruction in patients with Crowe type-IV developmental dysplasia of the hip. Using pelvic computed tomography and image processing, we developed a two-dimensional mapping technique to demonstrate the distribution of preoperative three-dimensional cup coverage at the true acetabulum, determined the postoperative location of the acetabular cup, and calculated postoperative three-dimensional coverage for 16 Crowe type-IV dysplastic hips in 14 patients with a mean age of 52 years (33-78 years) who underwent total hip arthroplasty. Mean follow-up was 6.3 years (5.5-7.3 years). On preoperative mapping, the maximum three-dimensional coverage using a 44-mm cup was 87.31% (77.36%-98.14%). Mapping enabled the successful replacement of 16 hips using a mean cup size of 44.13 mm (42-46 mm) with posterosuperior placement of the cup. Early weight-bearing and no prosthesis revision or loosening during follow-up were achieved in all patients. The postoperative two-dimensional coverage on anteroposterior radiographs and three-dimensional coverage were 96.15% (89.49%-100%) and 83.42% (71.81%-98.50%), respectively. This technique may improve long-term implant survival in patients with Crowe-IV developmental dysplasia of the hip undergoing total hip arthroplasty by allowing the use of durable bearings, increasing host bone coverage, ensuring initial stability, and restoring the normal hip center. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Management of long span partially edentulous maxilla with fixed removable denture prosthesis.

    Science.gov (United States)

    Jeyavalan, Mahilan I; Narasimman, M; Venkatakrishnan, C J; Philip, Jacob M

    2012-07-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  3. Identification of the Cause of the Stem Neck Fracture in the Hip Joint Endoprosthesis

    Science.gov (United States)

    Ryniewicz, A. M.; Bojko, Ł.; Ryniewicz, A.; Pałka, P.; Ryniewicz, W.

    2018-02-01

    Endoprosthesis stem fractures are among the rarest complications that occur after hip joint arthroplasty. The aim of this paper is to evaluate the causes of the fractures of the Aura II stem neck, which is an element of an endoprosthesis implanted in a patient. In order to achieve it, a radiogram was evaluated, the FEM analysis was carried out for the hip joint replaced using the Aura II prosthesis and scanning tests as well as a chemical analysis were performed for the focus of fatigue. The tests performed indicate that the most probable causes leading to the fatigue fracture of the Aura II stem under examination were material defects in the process of casting and forging (forging the material with delamination and the presence of brittle oxides and carbides) that resulted in a significant reduction of strength and resistance to corrosion. In the light of an unprecedented stem neck fracture, this information should be an indication for non-destructive tests of ready-made stems aiming to discover the material and technological defects that may arise in the process of casting and drop forging.

  4. 21 CFR 888.3810 - Wrist joint ulnar (hemi-wrist) polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint ulnar (hemi-wrist) polymer prosthesis. 888.3810 Section 888.3810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-wrist) polymer prosthesis. (a) Identification. A wrist joint ulnar (hemi-wrist) polymer prosthesis...

  5. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  6. The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants: a phantom study.

    Science.gov (United States)

    Harnish, Roy; Prevrhal, Sven; Alavi, Abass; Zaidi, Habib; Lang, Thomas F

    2014-07-01

    To determine if metal artefact reduction (MAR) combined with a priori knowledge of prosthesis material composition can be applied to obtain CT-based attenuation maps with sufficient accuracy for quantitative assessment of (18)F-fluorodeoxyglucose uptake in lesions near metallic prostheses. A custom hip prosthesis phantom with a lesion-sized cavity filled with 0.2 ml (18)F-FDG solution having an activity of 3.367 MBq adjacent to a prosthesis bore was imaged twice with a chrome-cobalt steel hip prosthesis and a plastic replica, respectively. Scanning was performed on a clinical hybrid PET/CT system equipped with an additional external (137)Cs transmission source. PET emission images were reconstructed from both phantom configurations with CT-based attenuation correction (CTAC) and with CT-based attenuation correction using MAR (MARCTAC). To compare results with the attenuation-correction method extant prior to the advent of PET/CT, we also carried out attenuation correction with (137)Cs transmission-based attenuation correction (TXAC). CTAC and MARCTAC images were scaled to attenuation coefficients at 511 keV using a trilinear function that mapped the highest CT values to the prosthesis alloy attenuation coefficient. Accuracy and spatial distribution of the lesion activity was compared between the three reconstruction schemes. Compared to the reference activity of 3.37 MBq, the estimated activity quantified from the PET image corrected by TXAC was 3.41 MBq. The activity estimated from PET images corrected by MARCTAC was similar in accuracy at 3.32 MBq. CTAC corrected PET images resulted in nearly 40 % overestimation of lesion activity at 4.70 MBq. Comparison of PET images obtained with the plastic and metal prostheses in place showed that CTAC resulted in a marked distortion of the (18)F-FDG distribution within the lesion, whereas application of MARCTAC and TXAC resulted in lesion distributions similar to those observed with the plastic replica. MAR combined

  7. Innovations in the management of hip fractures.

    Science.gov (United States)

    Teasdall, Robert D; Webb, Lawrence X

    2003-08-01

    Hip fractures include fractures of the head, neck, intertrochanteric, and subtrochanteric regions. Head fractures commonly accompany dislocations. Neck fractures and intertrochanteric fractures occur with greatest frequency in elderly patients with a low bone mineral density and are produced by low-energy mechanisms. Subtrochanteric fractures occur in a predominantly strong cortical osseous region that is exposed to large compressive stresses. Implants used to address these fractures must accommodate significant loads while the fractures consolidate. Complications secondary to hip fractures produce significant morbidity and include infection, nonunion, malunion, decubitus ulcers, fat emboli, deep venous thrombosis, pulmonary embolus, pneumonia, myocardial infarction, stroke, and death.

  8. Penile Corporeal Reconstruction during Difficult Placement of a Penile Prosthesis

    Directory of Open Access Journals (Sweden)

    Viet Q. Tran

    2008-01-01

    Full Text Available For some patients with impotence and concomitant severe tunical/corporeal tissue fibrosis, insertion of a penile prosthesis is the only option to restore erectile function. Closing the tunica over an inflatable penile prosthesis in these patients can be challenging. We review our previous study which included 15 patients with severe corporeal or tunical fibrosis who underwent corporeal reconstruction with autologous rectus fascia to allow placement of an inflatable penile prosthesis. At a mean follow-up of 18 months (range 12 to 64, all patients had a prosthesis that was functioning properly without evidence of separation, herniation, or erosion of the graft. Sexual activity resumed at a mean time of 9 weeks (range 8 to 10. There were no adverse events related to the graft or its harvest. Use of rectus fascia graft for coverage of a tunical defect during a difficult penile prosthesis placement is surgically feasible, safe, and efficacious.

  9. Support for total hip replacement surgery: Structures modeling, Gait Data Analysis and Report system

    Directory of Open Access Journals (Sweden)

    Gianluca Mario Izzo

    2012-03-01

    Full Text Available For the treatment of advanced damages of hip joints, Total Hip Arthroplasty is well proven. Due to the different mechanical properties of the prosthesis material and the bone tissue, a partial unloading of the periprosthetic bone occurs. The bone cement causes reduction in bone density as a result of removal of normal stress from the bone, leading to weakening of the bone in that area and the fracture risk increases. Bone loss is identified as one of the main reasons for loosening of the stem. Otherwise, thanks to the press-fit of the non-cemented stem achieved by surgery, the bone layers immediately adjacent to the stem are preloaded, thus encouraged growing, and the bone getting stronger. The non-cemented stem would be the better choice for every patient, but the question remains if the femur can handle the press- fitting surgery. This studies aim to develop a monitoring techniques based on Gait analysis and bone density changes to assess patient recovery after Total Hip Arthroplasty. Furthermore, to validate computational processes based on 3D modeling and Finite Element Methods for optimizing decision making in the operation process and selecting the suited surgical procedure. A vision could be minimizing risk of periprosthetic fracture during and after surgery. Patients: The sample presents 11 patients receiving cemented implant and 13 for the uncemented. Patients are grouped by type of implant. Three checkpoints were considered: before, after operation and one year later. CT scans, gaitrite and kinepro measurements have been realized. Main outcome measures: Fracture risk probability is higher in bone with low bone mineral density; therefore bones are more fragile in elderly people. BMD is indeed one parameter considered among all the observations. Periprosthetic fracture of the femur is a rare but complex complication of THA, and requires demanding surgery. As such, they result in considerable morbidity and dysfunction. Thus, tests of

  10. Tribology of total hip arthroplasty prostheses: What an orthopaedic surgeon should know.

    Science.gov (United States)

    Rieker, Claude B

    2016-02-01

    Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis.A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient.Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations.All combinations of bearing surface have their advantages and disadvantages. An appraisal of the individual patient's objectives should be part of the assessment of the best bearing surface. Cite this article: Rieker CB. Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know. EFORT Open Rev 2016;1:52-57. DOI: 10.1302/2058-5241.1.000004.

  11. Design and Control of a Pneumatically Actuated Transtibial Prosthesis.

    Science.gov (United States)

    Zheng, Hao; Shen, Xiangrong

    2015-04-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors' design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user.

  12. Prosthesis rejection in acquired major upper-limb amputees: a population-based survey.

    Science.gov (United States)

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-07-01

    To estimate the rates of primary and secondary prosthesis rejection in acquired major upper-limb amputees (ULAs), to describe the most frequently reported reasons for rejection and to estimate the influence of background factors on the risk of rejection. Cross-sectional study analysing population-based questionnaire data (n = 224). Effects were analysed by logistic regression analyses and Cox regression analyses. Primary prosthesis rejection was found in 4.5% whereas 13.4% had discontinued prosthesis use. The main reasons reported for primary non-wear were a perceived lack of need and discrepancies between perceived need and the prostheses available. The main reasons reported for secondary prosthesis rejection were dissatisfaction with prosthetic comfort, function and control. Primary prosthesis rejection was more likely in ULAs amputated at high age and in ULAs with proximal amputations. Secondary prosthesis rejection was more likely in proximal ULAs and in women. Clinicians should be aware of the increased risk of rejection in proximal ULAs, elderly ULAs and in women. Emphasising individual needs will probably facilitate successful prosthetic fitting. Improved prosthesis quality and individualised prosthetic training may increase long-term prosthesis use. Further studies of the effect of prosthetic training and of the reasons for rejection of different prosthetic types are suggested.

  13. Total hip and knee joint replacement: perioperative clinical aspects

    Directory of Open Access Journals (Sweden)

    Luciana Pereira Almeida de Piano

    2010-09-01

    Full Text Available Objective: To understand the profile of patients undergoing hip and knee replacement during two years, and to compare the data obtained with the literature. Methods: A total of 323 medical records were reviewed to analyze the perioperative data of patients submitted to hip and knee replacement. Results: Osteoarthritis was the main indication for both procedures and male patients were heavier than females (p < 0.05. Hypertension was the prevalent disease among patients. Blood loss was more frequent in knee surgery than in the hip. Conclusions: The profile of patients undergoing total arthroplasty improved substantially over the past decade due to shorter hospital stay, lower risk of thromboembolic events and no infection as compared to previous reports.

  14. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    Directory of Open Access Journals (Sweden)

    Mahilan I Jeyavalan

    2012-01-01

    Full Text Available Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  15. Hip, Hip, Soret!

    Science.gov (United States)

    Müller-Plathe, Florian

    Many years ago, Ludwig did detect the behaviour now called the Soret effect. Sodium sulphate in eighteen-fifty-six did not obediently follow Fick's first law. But if he cooled down one side the salt went left, the water to the right. He was surprised in every way. Hip, hip, Soret!

  16. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Science.gov (United States)

    2010-04-01

    ... implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3970 Interarticular disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis...

  17. Reading visual braille with a retinal prosthesis.

    Science.gov (United States)

    Lauritzen, Thomas Z; Harris, Jordan; Mohand-Said, Saddek; Sahel, Jose A; Dorn, Jessy D; McClure, Kelly; Greenberg, Robert J

    2012-01-01

    Retinal prostheses, which restore partial vision to patients blinded by outer retinal degeneration, are currently in clinical trial. The Argus II retinal prosthesis system was recently awarded CE approval for commercial use in Europe. While retinal prosthesis users have achieved remarkable visual improvement to the point of reading letters and short sentences, the reading process is still fairly cumbersome. This study investigates the possibility of using an epiretinal prosthesis to stimulate visual braille as a sensory substitution for reading written letters and words. The Argus II retinal prosthesis system, used in this study, includes a 10 × 6 electrode array implanted epiretinally, a tiny video camera mounted on a pair of glasses, and a wearable computer that processes the video and determines the stimulation current of each electrode in real time. In the braille reading system, individual letters are created by a subset of dots from a 3 by 2 array of six dots. For the visual braille experiment, a grid of six electrodes was chosen out of the 10 × 6 Argus II array. Groups of these electrodes were then directly stimulated (bypassing the camera) to create visual percepts of individual braille letters. Experiments were performed in a single subject. Single letters were stimulated in an alternative forced choice (AFC) paradigm, and short 2-4-letter words were stimulated (one letter at a time) in an open-choice reading paradigm. The subject correctly identified 89% of single letters, 80% of 2-letter, 60% of 3-letter, and 70% of 4-letter words. This work suggests that text can successfully be stimulated and read as visual braille in retinal prosthesis patients.

  18. Digital tomosynthesis with metal artifact reduction for assessing cementless hip arthroplasty: a diagnostic cohort study of 48 patients

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Hao; Yang, Dejin; Guo, Shengjie; Tang, Jing; Liu, Jian; Wang, Dacheng; Zhou, Yixin [Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Department of Orthopaedic Surgery, Beijing (China)

    2016-11-15

    For postoperative imaging assessment of cementless hip arthroplasty, radiography and computed tomography (CT) were restricted by overlapping structures and metal artifacts, respectively. A new tomosynthesis with metal artifact reduction (TMAR) is introduced by using metal extraction and ordered subset-expectation maximization (OS-EM) reconstruction. This study investigated the effectiveness of TMAR in assessing fixation stability of cementless hip arthroplasty components. We prospectively included 48 consecutive patients scheduled for revision hip arthroplasty in our hospital, with 41 femoral and 35 acetabular cementless components available for evaluation. All patients took the three examinations of radiography, CT, and TMAR preoperatively, with intraoperative mechanical tests, and absence or presence of osteointegration on retrieved prosthesis as reference standards. Three senior surgeons and four junior surgeons evaluated these images independently with uniform criteria. For TMAR, 82 % diagnoses on the femoral side and 84 % diagnoses on the acetabular side were accurate. The corresponding values were 44 and 67 % for radiography, and 39 % and 74 % for CT. Senior surgeons had significantly higher accuracy than junior surgeons by radiography (p < 0.05), but not by TMAR or CT. By minimizing metal artifacts in the bone-implant interface and clearly depicting peri-implant trabecular structures, the TMAR technique improved the diagnostic accuracy of assessing fixation stability of cementless hip arthroplasty, and shortened the learning curve of less experienced surgeons. Level II, diagnostic cohort study. (orig.)

  19. Efficacy of Antibiotic Suppressive Therapy in Patients with a Prosthetic Joint Infection

    NARCIS (Netherlands)

    Wouthuyzen-Bakker, Marjan; Nijman, Jasperina M; Kampinga, Greetje A; van Assen, Sander; Jutte, Paul C

    2017-01-01

    Introduction: For chronic prosthetic joint infections (PJI), complete removal of the infected prosthesis is necessary in order to cure the infection. Unfortunately, a subgroup of patients is not able to undergo a revision surgery due to high surgical risk. Alternatively, these patients can be

  20. Testicular prosthesis: Patient satisfaction and sexual dysfunctions in testis cancer survivors.

    Science.gov (United States)

    Catanzariti, Francesco; Polito, Benedetta; Polito, Massimo

    2016-10-05

    We studied patient satisfaction about sexual activity after prosthesis implantation using validated questionnaires with the aim to discover if testicular prosthesis could be responsible of sexual dysfunctions (erectile dysfunction or premature ejaculation). We evaluated a total of 67 men who underwent radical orchiectomy for testicular cancer and a silicon testicular prosthesis implantation from January 2008 to June 2014 at our Hospital. These patients completed 5 validated questionnaires the day before orchiectomy and 6 months after surgery: the International Index of Erectile Function 5 (IIEF5), the Premature Ejaculation Diagnostic Tool (PEDT), the Body Exposure during Sexual Activities Questionnaire (BESAQ), the Body-Esteem Scale and the Rosenberg Self- Esteem Scale. We also evaluated 6 months after surgery any defects of the prosthesis complained by the patients. The questionnaires completed by patients didn't show statistically significant changes for erectile dysfunction (p > 0.05) and premature ejaculation (p > 0.05). On the contrary the psychological questionnaires showed statistically significant change for the BESAQ (p < 0.001) and the Body Esteem Scale (p < 0.001), but not for the Rosenberg Self-Esteem Scale (p > 0,05). A total of 15 patients (22.37%) were dissatisfied about the prosthesis: the most frequent complaint (8 patients; 11.94%) was that the prosthesis was firmer than the normal testis. Testicular prosthesis implantation is a safe surgical procedure that should be always proposed before orchiectomy for cancer of the testis. The defects complained by patients with testicular prosthesis are few, they don't influence sexual activity and they aren't able to cause erectile dysfunction or premature ejaculation.

  1. Nasal prosthesis for a patient with xeroderma pigmentosum

    Directory of Open Access Journals (Sweden)

    Suresh Kumar

    2013-01-01

    Full Text Available Acquired facial defects caused by extirpation of neoplasms, congenital malformations or traumatic injury results in a huge functional, cosmetic and psychological handicap in those patients. These defects can be restored by facial prosthesis using different materials and retention methods to achieve a lifelike appearance and function. This clinical report describes a treatment schedule using silicone nasal prosthesis, which is mechanically retained for a patient who has undergone a partial rhinectomy due to basal cell carcinoma of the nose. The prosthesis was made to restore the esthetic appearance of patient with a mechanically retained design using a spectacle glass frame without any prosthetic adhesives so that the patient is more comfortable and confident to resume daily activities.

  2. The Tribology of Explanted Hip Resurfacings Following Early Fracture of the Femur.

    Science.gov (United States)

    Lord, James K; Langton, David J; Nargol, Antoni V F; Meek, R M Dominic; Joyce, Thomas J

    2015-10-15

    A recognized issue related to metal-on-metal hip resurfacings is early fracture of the femur. Most theories regarding the cause of fracture relate to clinical factors but an engineering analysis of failed hip resurfacings has not previously been reported. The objective of this work was to determine the wear volumes and surface roughness values of a cohort of retrieved hip resurfacings which were removed due to early femoral fracture, infection and avascular necrosis (AVN). Nine resurfacing femoral heads were obtained following early fracture of the femur, a further five were retrieved due to infection and AVN. All fourteen were measured for volumetric wear using a co-ordinate measuring machine. Wear rates were then calculated and regions of the articulating surface were divided into "worn" and "unworn". Roughness values in these regions were measured using a non-contacting profilometer. The mean time to fracture was 3.7 months compared with 44.4 months for retrieval due to infection and AVN. Average wear rates in the early fracture heads were 64 times greater than those in the infection and AVN retrievals. Given the high wear rates of the early fracture components, such wear may be linked to an increased risk of femoral neck fracture.

  3. The Tribology of Explanted Hip Resurfacings Following Early Fracture of the Femur

    Directory of Open Access Journals (Sweden)

    James K. Lord

    2015-10-01

    Full Text Available A recognized issue related to metal-on-metal hip resurfacings is early fracture of the femur. Most theories regarding the cause of fracture relate to clinical factors but an engineering analysis of failed hip resurfacings has not previously been reported. The objective of this work was to determine the wear volumes and surface roughness values of a cohort of retrieved hip resurfacings which were removed due to early femoral fracture, infection and avascular necrosis (AVN. Nine resurfacing femoral heads were obtained following early fracture of the femur, a further five were retrieved due to infection and AVN. All fourteen were measured for volumetric wear using a co-ordinate measuring machine. Wear rates were then calculated and regions of the articulating surface were divided into “worn” and “unworn”. Roughness values in these regions were measured using a non-contacting profilometer. The mean time to fracture was 3.7 months compared with 44.4 months for retrieval due to infection and AVN. Average wear rates in the early fracture heads were 64 times greater than those in the infection and AVN retrievals. Given the high wear rates of the early fracture components, such wear may be linked to an increased risk of femoral neck fracture.

  4. Control and Evaluation of a Powered Transfemoral Prosthesis for Stair Ascent.

    Science.gov (United States)

    Ledoux, Elissa D; Goldfarb, Michael

    2017-07-01

    This paper assesses the metabolic effort exerted by three transfemoral amputees, when using a powered knee and ankle prosthesis for stair ascent, relative to ascending stairs with passive knee and ankle prostheses. The paper describes a controller that provides step-over stair ascent behavior reflective of healthy stair ascent biomechanics, and describes its implementation in a powered prosthesis prototype. Stair ascent experiments were performed with three unilateral transfemoral amputee subjects, comparing the oxygen consumption required to ascend stairs using the powered prosthesis (with a step-over gait), relative to using their daily-use energetically passive prostheses (with a step-to gait). Results indicate on average a 24% reduction in oxygen consumption and a 30% reduction in stair ascent timewhen using the powered prosthesis, relative to when using the passive prostheses. All subjects expressed a strong preference for ascending stairs using the powered prosthesis.

  5. The Role of BMI in Hip Fracture Surgery.

    Science.gov (United States)

    Akinleye, Sheriff D; Garofolo, Garret; Culbertson, Maya Deza; Homel, Peter; Erez, Orry

    2018-01-01

    Obesity is an oft-cited cause of surgical morbidity and many institutions require extensive supplementary screening for obese patients prior to surgical intervention. However, in the elderly patients, obesity has been described as a protective factor. This article set out to examine the effect of body mass index (BMI) on outcomes and morbidity after hip fracture surgery. The National Surgical Quality Improvement Program database was queried for all patients undergoing 1 of 4 surgical procedures to manage hip fracture between 2008 and 2012. Patient demographics, BMI, and known factors that lead to poor surgical outcomes were included as putative predictors for complications that included infectious, cardiac, pulmonary, renal, and neurovascular events. Using χ 2 tests, 30-day postoperative complication rates were compared between 4 patient groups stratified by BMI as low weight (BMI BMI = 20-30), obese (BMI = 30-40), and morbidly obese (BMI > 40). A total of 15 108 patients underwent surgery for hip fracture over the examined 5-year period. Of these, 18% were low weight (BMI BMI = 20-30), 13% were obese (BMI = 30-40), and 2% were morbidly obese (BMI > 40). The low-weight and morbidly obese patients had both the highest mortality rates and the lowest superficial infection rates. There was a significant increase in blood transfusion rates that decreased linearly with increasing BMI. Deep surgical site infection and renal failure increased linearly with increasing BMI, however, these outcomes were confounded by comorbidities. This study demonstrates that patients at either extreme of the BMI spectrum, rather than solely the obese, are at greatest risk of major adverse events following hip fracture surgery. This runs contrary to the notion that obese hip fracture patients automatically require additional preoperative screening and perioperative services, as currently implemented in many institutions.

  6. Perioperative mortality in hip fracture patients treated with cemented and uncemented hemiprosthesis: a register study of 11,210 patients.

    Science.gov (United States)

    Talsnes, Ove; Vinje, Tarjei; Gjertsen, Jan Erik; Dahl, Ola E; Engesæter, Lars B; Baste, Valborg; Pripp, Are Hugo; Reikerås, Olav

    2013-06-01

    Adverse events associated with the use of bone cement for fixation of prostheses is a known complication. Due to inconclusive results in studies of hip fracture patients treated with cemented and uncemented hemiprostheses, this study was initiated. Our study is based on data reported to the Norwegian Hip Fracture Register on 11,210 cervical hip fractures treated with hemiprostheses (8,674 cemented and 2,536 uncemented). Significantly increased mortality within the first day of surgery was found in the cemented group (relative risk 2.9, 95 % confidence interval 1.6-5.1, p=0.001). The finding was robust giving the same results after adjusting for independent risk factors such as age, sex, cognitive impairment and comorbidity [American Society of Anesthesiologists (ASA) score]. For the first post-operative day the number needed to harm was 116 (one death for every 116 cemented prosthesis). However, in the most comorbid group (ASA worse than 3), the number needed to harm was only 33. We found increased mortality for the cemented hemiprosthesis the first post-operative day compared to uncemented procedures. This increased risk is closely related to patient comorbidity estimated by the patient's ASA score.

  7. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation

    Directory of Open Access Journals (Sweden)

    Cheng Chen

    2016-04-01

    Full Text Available ABSTRACT INTRODUCTION: Maxillary defects are usually rehabilitated by a prosthetic obturator. OBJECTIVE: This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. METHODS: Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS. RESULTS: From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP, 11 (39% with an enhanced retentive obturator prosthesis with stud attachment (POP and 8 (28% with an enhanced retentive obturator prosthesis with magnetic attachment (POM. The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p < 0.05 among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p < 0.05 both in MOP and AOP groups. CONCLUSION: Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function.

  8. Testicular prosthesis: Patient satisfaction and sexual dysfunctions in testis cancer survivors

    Directory of Open Access Journals (Sweden)

    Francesco Catanzariti

    2016-10-01

    Full Text Available Purpose: We studied patient satisfaction about sexual activity after prosthesis implantation using validated questionnaires with the aim to discover if testicular prosthesis could be responsible of sexual dysfunctions (erectile dysfunction or premature ejaculation. Materials and Methods: We evaluated a total of 67 men who underwent radical orchiectomy for testicular cancer and a silicon testicular prosthesis implantation from January 2008 to June 2014 at our Hospital. These patients completed 5 validated questionnaires the day before orchiectomy and 6 months after surgery: the International Index of Erectile Function 5 (IIEF5, the Premature Ejaculation Diagnostic Tool (PEDT, the Body Exposure during Sexual Activities Questionnaire (BESAQ, the Body-Esteem Scale and the Rosenberg Self- Esteem Scale. We also evaluated 6 months after surgery any defects of the prosthesis complained by the patients. Results: The questionnaires completed by patients didn’t show statistically significant changes for erectile dysfunction (p > 0.05 and premature ejaculation (p > 0.05. On the contrary the psychological questionnaires showed statistically significant change for the BESAQ (p < 0.001 and the Body Esteem Scale (p < 0.001, but not for the Rosenberg Self-Esteem Scale (p > 0,05. A total of 15 patients (22.37% were dissatisfied about the prosthesis: the most frequent complaint (8 patients; 11.94% was that the prosthesis was firmer than the normal testis. Conclusions: Testicular prosthesis implantation is a safe surgical procedure that should be always proposed before orchiectomy for cancer of the testis. The defects complained by patients with testicular prosthesis are few, they don’t influence sexual activity and they aren’t able to cause erectile dysfunction or premature ejaculation.

  9. 3D printing technology used in severe hip deformity.

    Science.gov (United States)

    Wang, Shanshan; Wang, Li; Liu, Yan; Ren, Yongfang; Jiang, Li; Li, Yan; Zhou, Hao; Chen, Jie; Jia, Wenxiao; Li, Hui

    2017-09-01

    This study was designed to assess the use of a 3D printing technique in total hip arthroplasty (THA) for severe hip deformities, where new and improved approaches are needed. THAs were performed from January 2015 to December 2016. Bioprosthesis artificial hip joints were used in both conventional and 3D printing hip arthroplasties. A total of 74 patients (57 cases undergoing conventional hip replacements and 17 undergoing 3D printing hip replacements) were followed-up for an average of 24 months. The average age of the patients was 62.7 years. Clinical data between the patients treated with different approaches were compared. Results showed that the time to postoperative weight bearing and the Harris scores of the patients in the 3D printing group were better than those for patients in the conventional hip replacement group. Unfortunately, the postoperative infection and loosening rates were higher in the 3D printing group. However, there were no significant differences in femoral neck anteversion, neck shaft, acetabular or sharp angles between ipsilateral and contralateral sides in the 3D printing group (P>0.05). The femoral neck anteversion angle was significantly different between the two sides in the conventional hip replacement group (P3D printing approach provides a better short-term curative effect that is more consistent with the physiological structure and anatomical characteristics of the patient, and we anticipate that its use will help improve the lives of many patients.

  10. Rates of hip and knee joint replacement amongst different ethnic groups in England: an analysis of National Joint Registry data.

    Science.gov (United States)

    Smith, M C; Ben-Shlomo, Y; Dieppe, P; Beswick, A D; Adebajo, A O; Wilkinson, J M; Blom, A W

    2017-04-01

    Despite a health care system that is free at the point of delivery, ethnic minorities may not always get care equitable to that of White patients in England. We examined whether ethnic differences exist in joint replacement rates and surgical practice in England. 373,613 hip and 428,936 knee National Joint Registry (NJR) primary replacement patients had coded ethnicity in Hospital Episode Statistics (HES). Age and gender adjusted observed/expected ratios of hip and knee replacements amongst ethnic groups were compared using indirect standardisation. Associations between ethnic group and type of procedure were explored and effects of demographic, clinical and hospital-related factors examined using multivariable logistic regression. Adjusted standardised observed/expected ratios were substantially lower in Blacks and Asians than Whites for hip replacement (Blacks 0.33 [95% CI, 0.31-0.35], Asians 0.20 [CI, 0.19-0.21]) and knee replacement (Blacks 0.64 [CI, 0.61-0.67], Asians 0.86 % [CI, 0.84-0.88]). Blacks were more likely to receive uncemented hip replacements (Blacks 52%, Whites 37%, Asians 44%; P replacements than Whites (men 10% vs 15%, P = 0.001; women 6% vs 14%, P replacement (OR 1.43 [CI, 1.11-1.84]). In England, hip and knee replacement rates and prosthesis type given differ amongst ethnic groups. Whether these reflect differences in clinical need or differential access to treatment requires urgent investigation. Copyright © 2017. Published by Elsevier Ltd.

  11. Experimental substantiation of a method of early diagnosis of infectivity of vascular prostheses with the help of 99mTc-leukocytes

    International Nuclear Information System (INIS)

    Zatevakhin, I.I.; Malov, G.A.; Govorunov, G.V.; Dobronravov, D.S.; Makhmudov, S.Ya.; Komrakov, V.E.

    1988-01-01

    Experiments on 9 dogs were staged for a study of a method of early diagnosis of infectivity of vascular prostheses of the abdominal aorta with the help of 99m Tc-labeled leukocytes. A sterile synthetic vascular prosthesis was used for prosthetics of the abdominal aorta in the 1st control group of animals, a prosthesis, previously infected with St. aureus, was used in the 2nd group, a sterile prosthesis with its subsequent infecting by i.v. injection of St. aureus was used in the 3rd group. The tolre of antibiotic therapy in infectivity of vascular prostheses was studied on the animals of the 3rd group. A radionuclide study with autologous 99m Tc-labeled leukocytes was conducted using the Deina-2 camera (Picker). Visualization of the prostheses was unobserved in the 1st control group; in the 2nd group the accumulation of 99m Tc-leucocytes in the zone of the prosthesis and its vizualization on the 4th-5th min. were noted; in the 3rd group the prothesis was visualized on the 10th-15th min. After antibiotic therapy in the 3rd group visualization of the prothesis was undetectable. The proposed method permitted visualization of a zone of infection in the early postoperative period, observation of the time course of infection development, and assessment of the efficacy of antibiotic therapy

  12. The unsuspected prosthetic joint infection : incidence and consequences of positive intra-operative cultures in presumed aseptic knee and hip revisions.

    Science.gov (United States)

    Jacobs, A M E; Bénard, M; Meis, J F; van Hellemondt, G; Goosen, J H M

    2017-11-01

    Positive cultures are not uncommon in cases of revision total knee and hip arthroplasty (TKA and THA) for presumed aseptic causes. The purpose of this study was to assess the incidence of positive intra-operative cultures in presumed aseptic revision of TKA and THA, and to determine whether the presence of intra-operative positive cultures results in inferior survival in such cases. A retrospective cohort study was assembled with 679 patients undergoing revision knee (340 cases) or hip arthroplasty (339 cases) for presumed aseptic causes. For all patients three or more separate intra-operative cultures were obtained. Patients were diagnosed with a previously unsuspected prosthetic joint infection (PJI) if two or more cultures were positive with the same organism. Records were reviewed for demographic details, pre-operative laboratory results and culture results. The primary outcome measure was infection-free implant survival at two years. The incidence of unsuspected PJI was 27 out of 340 (7.9%) in TKA and 41 out of 339 (12.1%) in THA. Following revision TKA, the rate of infection-free implant survival in patients with an unsuspected PJI was 88% (95% confidence intervals (CI) 60 to 97) at two years compared with 98% (95% CI 94 to 99) in patients without PJI (p = 0.001). After THA, the rate of survival was similar in those with unsuspected PJI (92% (95% CI 73 to 98) at two years) and those without (94% (95% CI 89 to 97), p = 0.31). Following revision of TKA and THA for aseptic diagnoses, around 10% of cases were found to have positive cultures. In the knee, such cases had inferior infection-free survival at two years compared with those with negative cultures; there was no difference between the groups following THA. Cite this article: Bone Joint J 2017;99-B:1482-9. ©2017 The British Editorial Society of Bone & Joint Surgery.

  13. Use of Powered Prosthesis for Children with Upper Limb Deficiency at Hyogo Rehabilitation Center.

    Directory of Open Access Journals (Sweden)

    Mitsunori Toda

    Full Text Available There has been no research investigating the use of powered prosthetic for children in Japan.To gain better insight into the state of powered prosthesis usage and identify a ratio of rejection among children.Subjects were 37 unilateral below elbow amputees between the ages of 0 and 16 at the time of their first experienced fitting with a powered prosthesis at our Center. The information was collected from medical records and through face-to-face interviews, and we examined rejection rate and the factors affecting the use of powered prosthesis.The rate of discontinuation was 21.6% as 8 of the 37 children stopped using powered prosthesis. All of them were fitted their prosthesis after 2 years of age, and they rejected prosthesis between 5 to 19 years. We found that the level of amputation had no influence on the use of a powered prosthesis.Children fitted before 2 years of age tend to accept their powered prosthesis than those fitted after 2 years. Multidisciprinary team approach, adequate rehabilitation, detailed follow-up and involvement of parents are quite important for introducing powered prosthesis for children.

  14. Changes in performance over time while learning to use a myoelectric prosthesis

    NARCIS (Netherlands)

    Bouwsema, Hanneke; van der Sluis, Corry K.; Bongers, Raoul M.

    2014-01-01

    Background: Training increases the functional use of an upper limb prosthesis, but little is known about how people learn to use their prosthesis. The aim of this study was to describe the changes in performance with an upper limb myoelectric prosthesis during practice. The results provide a basis

  15. Evaluation of the Quality of Life and Psychiatric Symptoms of Patients with Primary Coxarthrosis after Total Hip Arthroplasty.

    Science.gov (United States)

    Balik, M S; Hocaoğlu, Ç; Erkut, A; Güvercin, Y; Keskin, D

    2017-01-01

    PURPOSE OF THE STUDY In this study, it was aimed to examine the preoperative and postoperative quality of life and psychiatric symptoms of the patients with primary coxarthrosis after total hip arthroplasty. MATERIAL AND METHODS 150 patients undergone total hip arthroplasty were involved in this study. The socio-demographical data form prepared by the researchers was utilized before and after the operation in order to demonstrate disease-related socio-demographical characteristics of the patient. The Quality of Life Scale Short Form (SF-36), Beck Depression Inventory (BDI), Beck Anxiety Inventory (BAI), Harris Hip Score (HHS) and Visual Analog Scale (VSA) were implemented in the preoperative period and at 6th and 12th week after the operation. RESULTS Of the patients involved in study, 28.7% were male and 71.3% were female. Their mean age was 58.34±11.92 year. While statistically significant differences were found between the preoperative and postoperative periods in terms of physical function, physical role limitation, emotional role limitation, energy, social function, pain, and general health subscales of SF-36, no significant differences were found relating mental health subscale. In BAI, BDI, VAS, and HHS comparison, statistically significant differences were found between the preoperative and postoperative periods, except for BAI. CONCLUSIONS In this study, it was determined that primary coxarthrosis affects significantly the quality of the patients' lives in a negative way and can be accompanied by mental symptoms. After total hip arthroplasty, significant improvement was observed in quality of life, depression and pain scores. Key words: total hip prosthesis, quality of life, mental symptoms.

  16. Hip joint replacement

    Science.gov (United States)

    Hip arthroplasty; Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... Your hip joint is made up of 2 major parts. One or both parts may be replaced during surgery: ...

  17. Design of a power-asymmetric actuator for a transtibial prosthesis.

    Science.gov (United States)

    Bartlett, Harrison L; Lawson, Brian E; Goldfarb, Michael

    2017-07-01

    This paper presents the design and characterization of a power-asymmetric actuator for a transtibial prosthesis. The device is designed to provide the combination of: 1) joint locking, 2) high power dissipation, and 3) low power generation. This actuator functionality allows for a prosthesis to be designed with minimal mass and power consumption relative to a fully-powered robotic prosthesis while maintaining much of the functionality necessary for activities of daily living. The actuator achieves these design characteristics while maintaining a small form factor by leveraging a combination of electromechanical and hydraulic components. The design of the actuator is described herein, and results of an experimental characterization are provided that indicate that the actuator is capable of providing the functional capabilities required of an ankle prosthesis in a compact and lightweight package.

  18. Impact of operative time on early joint infection and deep vein thrombosis in primary total hip arthroplasty.

    Science.gov (United States)

    Wills, B W; Sheppard, E D; Smith, W R; Staggers, J R; Li, P; Shah, A; Lee, S R; Naranje, S M

    2018-03-22

    Infections and deep vein thrombosis (DVT) after total hip arthroplasty (THA) are challenging problems for both the patient and surgeon. Previous studies have identified numerous risk factors for infections and DVT after THA but have often been limited by sample size. We aimed to evaluate the effect of operative time on early postoperative infection as well as DVT rates following THA. We hypothesized that an increase in operative time would result in increased odds of acquiring an infection as well as a DVT. We conducted a retrospective analysis of prospectively collected data using the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database from 2006 to 2015 for all patients undergoing primary THA. Associations between operative time and infection or DVT were evaluated with multivariable logistic regressions controlling for demographics and several known risks factors for infection. Three different types of infections were evaluated: (1) superficial surgical site infection (SSI), an infection involving the skin or subcutaneous tissue, (2) deep SSI, an infection involving the muscle or fascial layers beneath the subcutaneous tissue, and (3) organ/space infection, an infection involving any part of the anatomy manipulated during surgery other than the incisional components. In total, 103,044 patients who underwent THA were included in our study. Our results suggested a significant association between superficial SSIs and operative time. Specifically, the adjusted odds of suffering a superficial SSI increased by 6% (CI=1.04-1.08, ptime. When using dichotomized operative time (90minutes), the adjusted odds of suffering a superficial SSI was 56% higher for patients with prolonged operative time (CI=1.05-2.32, p=0.0277). The adjusted odds of suffering a deep SSI increased by 7% for every 10-minute increase in operative time (CI=1.01-1.14, p=0.0335). No significant associations were detected between organ/space infection, wound

  19. [Three-dimensional finite element analysis on mechanical behavior of the bone remodeling and bone integration between the bone-implant interface after hip replacement].

    Science.gov (United States)

    Li, Yong-Jiang; Zhang, Li-Cheng; Zhang, Mei-Chao; Yang, Guo-Jing; Lin, Rui-Xin; Cai, Chun-Yuan; Zhong, Shi-Zhen

    2014-04-01

    To discuss the primary stability of the fixed interface between the cementless prosthesis and femur, and its influence on bone ingrowth and secondary stability under the roughened surface and press fit of different prostheses by finite element analysis. :A three-dimensional finite element module of total hip arthroplasty (THA) was developed with Mimics software. There was a collection of data when simulating hip arthroplasty. The frictional coefficient between the fixed interface was 0,0.15,0.40 and 1.00 representing the roughness of prosthesis surface. The press fit was 0, 0.01,0.05 and 0.10 mm according to the operation. The Vion Mises stress distribution and the contact pressure,friction stress and relative sliding displacement between the interface were analysed and compared when simulating the maneuver of climbing stairs. At a fixed press fit of 0.05 mm,the contact pressure between the interface was 230 , 231, 222 and 275 MN under four different frictional coefficient (0,0. 15,0.40 and 1.00) with little change; the relative sliding displacement was 0.529, 0.129, 0.107 and 0.087 mm with a consistent and obvious decline. As the fixed frictional coefficient was 0.40,the contact pressure between the interface were 56.0,67.7 ,60.4 and 49.6 MN under four different press fit (0, 0.01, 0.05 and 0.10 mm) with a reduction; the relative sliding displacement was 0.064,0.062,0.043 and 0.042 mm with an obvious decline, and there was a maximal friction stress when press fit of 0.01 mm. There is a dynamic process of the bone remodeling and bone integration between the interface after hip replacement, determining the long-term outcome. The interface clearance and the frictional coefficient are the key factors of the bone integration.

  20. Hip Arthroscopy Surgical Volume Trends and 30-Day Postoperative Complications.

    Science.gov (United States)

    Cvetanovich, Gregory L; Chalmers, Peter N; Levy, David M; Mather, Richard C; Harris, Joshua D; Bush-Joseph, Charles A; Nho, Shane J

    2016-07-01

    To determine hip arthroscopy surgical volume trends from 2006 to 2013 using the National Surgical Quality Improvement Program (NSQIP) database, the incidence of 30-day complications of hip arthroscopy, and patient and surgical risk factors for complications. Patients who underwent hip arthroscopy from 2006 to 2013 were identified in the NSQIP database for the over 400 NSQIP participating hospitals from the United States using Current Procedural Terminology and International Classification of Diseases, Ninth Revision codes. Trends in number of hip arthroscopy procedures per year were analyzed. Complications in the 30-day period after hip arthroscopy were identified. Univariate and multivariate regression analyses were performed to identify risk factors for complications. We identified 1,338 patients who underwent hip arthroscopy, with a mean age of 39.5 ± 13.0 years. Female patients comprised 59.6%. Hip arthroscopy procedures became 25 times more common in 2013 than 2006 (P arthroscopy. Hip arthroscopy is an increasingly common procedure, with a 25-fold increase from 2006 to 2013. There is a low incidence of 30-day postoperative complications (1.3%), most commonly bleeding requiring a transfusion, return to the operating room, and superficial infection. Regional/monitored anesthesia care and steroid use were independent risk factors for minor complications. Level III, retrospective comparative study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. [A therapeutic effect analysis of femur first principle and combined anteversion technique during total hip arthroplasty].

    Science.gov (United States)

    Wang, X Q; Wu, C S; Sun, S; Wang, J; Li, W; Zhang, W

    2018-04-01

    Objective: To investigate the situation of hip dislocation with the application of "femur first" principle and "combined anteversion technique" during total hip arthroplasty. Methods: A retrospective analysis has been done on the clinical data about 104 patients(133 hips)who were diagnosed as hip disease and were treated with total hip arthroplasty by the doctors from the Department of Joint Orthorpaedics of Shandong Provincial Hospital Affiliated to Shandong University from June 2014 to June 2016, and all the prostheses applied in the operation were cementless ones.Among them, 65 patients were males, 39 females and their age was 46.6 years (ranging from 23 to 76 years) .And 29 of them underwent bilateral hip operations and 75 unilateral ones.Seventy-six cases of aseptic necrosis of the femoral head in the terminal stage, 28 cases of hip dysplasia and osteoarthritis.Surgical approach: of all the operations, 103 hips were operated on with hardinge approach, 30 with posterolateral approach.During the operation, first of all, the femoral medullary cavity was broached and then the anteversion of intramedullary broacher was measured.After that, the anteversion of the acetabular cup was calculated as 37° minus the anteversion of the broacher, and the acetabular cup was implanted at that angle.The patients' prosthesis combined anteversion, range of motion of the hip joint, operation time, hemorrhage amount, and complications had been kept record.One, three, and six months respectively after the operation, all the patients received outpatient review, and took anteroposterior and lateral position X-ray examination.Harris hip score had been applied to evaluate their hip function before the operation and six months after the operation. Results: All the patients had been operated on smoothly, with the operation time of(57.6±14.5)minutes(36-115 minutes)and hemorrhage amount of (336.5±50.8)ml(180-620 ml). The operation finding showed that the combined anteversion by employing

  2. Cranioplasty prosthesis manufacturing based on reverse engineering technology

    Science.gov (United States)

    Chrzan, Robert; Urbanik, Andrzej; Karbowski, Krzysztof; Moskała, Marek; Polak, Jarosław; Pyrich, Marek

    2012-01-01

    Summary Background Most patients with large focal skull bone loss after craniectomy are referred for cranioplasty. Reverse engineering is a technology which creates a computer-aided design (CAD) model of a real structure. Rapid prototyping is a technology which produces physical objects from virtual CAD models. The aim of this study was to assess the clinical usefulness of these technologies in cranioplasty prosthesis manufacturing. Material/Methods CT was performed on 19 patients with focal skull bone loss after craniectomy, using a dedicated protocol. A material model of skull deficit was produced using computer numerical control (CNC) milling, and individually pre-operatively adjusted polypropylene-polyester prosthesis was prepared. In a control group of 20 patients a prosthesis was manually adjusted to each patient by a neurosurgeon during surgery, without using CT-based reverse engineering/rapid prototyping. In each case, the prosthesis was implanted into the patient. The mean operating times in both groups were compared. Results In the group of patients with reverse engineering/rapid prototyping-based cranioplasty, the mean operating time was shorter (120.3 min) compared to that in the control group (136.5 min). The neurosurgeons found the new technology particularly useful in more complicated bone deficits with different curvatures in various planes. Conclusions Reverse engineering and rapid prototyping may reduce the time needed for cranioplasty neurosurgery and improve the prosthesis fitting. Such technologies may utilize data obtained by commonly used spiral CT scanners. The manufacturing of individually adjusted prostheses should be commonly used in patients planned for cranioplasty with synthetic material. PMID:22207125

  3. Radiographic and tomographic evaluation of total hybrid hip replacement in dogs; Avaliacao radiografica e tomografica de caes submetidosa artroplastia coxofemoral total hibrida

    Energy Technology Data Exchange (ETDEWEB)

    Minto, B.W., E-mail: brunowminto@gmail.com [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Jaboticabal, SP (Brazil); Brandao, C.V.S.; Pereira, G.J.C.; Babicsak, V.R.; Vulcano, L.C.; Rossetto, V.J.V. [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Botucatu, SP (Brazil)

    2016-11-15

    The total hip arthroplasty is the most effective surgical technique for the treatment of severe canine hip dysplasia. Currently, the radiographic examination is the most common method used to assess this procedure in dogs, but has some limitations. CT scan by computed tomography instead enables the acquisition of images without overlap, thereby determining the positioning of prosthetic components with greater accuracy. This research aimed to evaluate by radiography and CT scan examinations the use of a hybrid modular total hip prosthesis developed and made in Brazil, applied experimentally in healthy dogs. Six skeletally mature dogs, which previously underwent surgery on the left hip joint were used. The dogs underwent CT scan at 360 days and three years after surgery. All animals showed good positioning of prosthetic components, and proper joint reduction. In the CT scan, however, it was possible to detect irregular fill areas in some animals. In addition, CT scan allowed the detection and monitoring of areas of bone resorption around the acetabular component. Therefore, the CT scan was useful in the evaluation of prosthetic joints, with the advantage of optimum sharpness of the images and allowing for the possibility of quantifying peri-prosthetic changes and measure joint, fundamental relations for late postoperative follow-up. (author)

  4. Antibiotikumprofylakse ved tandbehandling hos patienter med hofte- eller knaeledsalloplastik er sjaeldent nødvendig

    DEFF Research Database (Denmark)

    Jørgensen, Peter Holmberg; Fuursted, Kurt; Holmstrup, Palle

    2010-01-01

    A review of the literature with respect to whether antibiotic prophylaxis should be recommended in relation to dental treatment of patients with hip or knee joint prosthesis. We find no evidence for such a general recommendation. As neutropenic patients and patients with rheumatoid arthritis are ...... are generally more prone to develop periprosthetic infections it can be considered in these cases to give prophylactic antibiotics before more extensive dental treatments....

  5. C-reactive protein, erythrocyte sedimentation rate and orthopedic implant infection.

    Directory of Open Access Journals (Sweden)

    Kerryl E Piper

    Full Text Available BACKGROUND: C-reactive protein (CRP and erythrocyte sedimentation rate (ESR have been shown to be useful for diagnosis of prosthetic hip and knee infection. Little information is available on CRP and ESR in patients undergoing revision or resection of shoulder arthroplasties or spine implants. METHODS/RESULTS: We analyzed preoperative CRP and ESR in 636 subjects who underwent knee (n=297, hip (n=221 or shoulder (n=64 arthroplasty, or spine implant (n=54 removal. A standardized definition of orthopedic implant-associated infection was applied. Receiver operating curve analysis was used to determine ideal cutoff values for differentiating infected from non-infected cases. ESR was significantly different in subjects with aseptic failure infection of knee (median 11 and 53.5 mm/h, respectively, p=<0.0001 and hip (median 11 and 30 mm/h, respectively, p=<0.0001 arthroplasties and spine implants (median 10 and 48.5 mm/h, respectively, p=0.0033, but not shoulder arthroplasties (median 10 and 9 mm/h, respectively, p=0.9883. Optimized ESR cutoffs for knee, hip and shoulder arthroplasties and spine implants were 19, 13, 26, and 45 mm/h, respectively. Using these cutoffs, sensitivity and specificity to detect infection were 89 and 74% for knee, 82 and 60% for hip, and 32 and 93% for shoulder arthroplasties, and 57 and 90% for spine implants. CRP was significantly different in subjects with aseptic failure and infection of knee (median 4 and 51 mg/l, respectively, p<0.0001, hip (median 3 and 18 mg/l, respectively, p<0.0001, and shoulder (median 3 and 10 mg/l, respectively, p=0.01 arthroplasties, and spine implants (median 3 and 20 mg/l, respectively, p=0.0011. Optimized CRP cutoffs for knee, hip, and shoulder arthroplasties, and spine implants were 14.5, 10.3, 7, and 4.6 mg/l, respectively. Using these cutoffs, sensitivity and specificity to detect infection were 79 and 88% for knee, 74 and 79% for hip, and 63 and 73% for shoulder arthroplasties, and 79 and

  6. 3D Printing Aids Acetabular Reconstruction in Complex Revision Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Andrew J. Hughes

    2017-01-01

    Full Text Available Revision hip arthroplasty requires comprehensive appreciation of abnormal bony anatomy. Advances in radiology and manufacturing technology have made three-dimensional (3D representation of osseous anatomy obtainable, which provide visual and tactile feedback. Such life-size 3D models were manufactured from computed tomography scans of three hip joints in two patients. The first patient had undergone multiple previous hip arthroplasties for bilateral hip infections, resulting in right-sided pelvic discontinuity and a severe left-sided posterosuperior acetabular deficiency. The second patient had a first-stage revision for infection and recurrent dislocations. Specific metal reduction protocols were used to reduce artefact. The images were imported into Materialise MIMICS 14.12®. The models were manufactured using selective laser sintering. Accurate templating was performed preoperatively. Acetabular cup, augment, buttress, and cage sizes were trialled using the models, before being adjusted, and resterilised, enhancing the preoperative decision-making process. Screw trajectory simulation was carried out, reducing the risk of neurovascular injury. With 3D printing technology, complex pelvic deformities were better evaluated and treated with improved precision. Life-size models allowed accurate surgical simulation, thus improving anatomical appreciation and preoperative planning. The accuracy and cost-effectiveness of the technique should prove invaluable as a tool to aid clinical practice.

  7. Magnetic-resonance-imaging-based three-dimensional muscle reconstruction of hip abductor muscle volume in a person with a transfemoral bone-anchored prosthesis : A feasibility study

    NARCIS (Netherlands)

    Leijendekkers, Ruud A.; Marra, Marco A.; Ploegmakers, Marieke J.M.; Van Hinte, Gerben; Frölke, Jan Paul; Van De Meent, Hendrik; Staal, J. Bart; Hoogeboom, Thomas J.; Verdonschot, Nico

    2018-01-01

    Background: Persons with transfemoral amputation typically have severe muscle atrophy of the residual limb. The effect of bone-anchored prosthesis use on existing muscle atrophy is unknown. A potentially feasible method to evaluate this is magnetic resonance imaging (MRI)-based three-dimensional

  8. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation.

    Science.gov (United States)

    Chen, Cheng; Ren, Wenhao; Gao, Ling; Cheng, Zheng; Zhang, Linmei; Li, Shaoming; Zhi, Pro Ke-qian

    2016-01-01

    Maxillary defects are usually rehabilitated by a prosthetic obturator. This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS). From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP), 11 (39%) with an enhanced retentive obturator prosthesis with stud attachment (POP) and 8 (28%) with an enhanced retentive obturator prosthesis with magnetic attachment (POM). The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p<0.05) among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p<0.05) both in MOP and AOP groups. Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  9. Diagnosis Of Persistent Infection In Prosthetic Two-Stage Exchange: PCR analysis of Sonication fluid From Bone Cement Spacers.

    Science.gov (United States)

    Mariaux, Sandrine; Tafin, Ulrika Furustrand; Borens, Olivier

    2017-01-01

    Introduction: When treating periprosthetic joint infections with a two-stage procedure, antibiotic-impregnated spacers are used in the interval between removal of prosthesis and reimplantation. According to our experience, cultures of sonicated spacers are most often negative. The objective of our study was to investigate whether PCR analysis would improve the detection of bacteria in the spacer sonication fluid. Methods: A prospective monocentric study was performed from September 2014 to January 2016. Inclusion criteria were two-stage procedure for prosthetic infection and agreement of the patient to participate in the study. Beside tissues samples and sonication, broad range bacterial PCRs, specific S. aureus PCRs and Unyvero-multiplex PCRs were performed on the sonicated spacer fluid. Results: 30 patients were identified (15 hip, 14 knee and 1 ankle replacements). At reimplantation, cultures of tissue samples and spacer sonication fluid were all negative. Broad range PCRs were all negative. Specific S. aureus PCRs were positive in 5 cases. We had two persistent infections and four cases of infection recurrence were observed, with bacteria different than for the initial infection in three cases. Conclusion: The three different types of PCRs did not detect any bacteria in spacer sonication fluid that was culture-negative. In our study, PCR did not improve the bacterial detection and did not help to predict whether the patient will present a persistent or recurrent infection. Prosthetic 2-stage exchange with short interval and antibiotic-impregnated spacer is an efficient treatment to eradicate infection as both culture- and molecular-based methods were unable to detect bacteria in spacer sonication fluid after reimplantation.

  10. Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.

    Science.gov (United States)

    Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J

    2017-07-01

    The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.

  11. Doppler derived gradient of ST Jude Mechanical Prosthesis, early postoperative assessment

    International Nuclear Information System (INIS)

    Shaikh, A.H.; Hanif, B.; Adil, A.; Hashimi, S.; Qazi, H.A.; Mujtaba, I.

    2010-01-01

    Objective: To determine the doppler derived mean gradients of St Jude mechanical prosthesis in early postoperative period in patients undergoing valve replacement at a tertiary care cardiac centre. Methods: Medical records of 190 consecutive patients who underwent 233 mitral, aortic or dual (mitral and aortic) valve replacement by St Jude bileaflet mechanical prosthesis at Tabba Heart Institute, between March 2006 to December 2008 were reviewed. Doppler derived mean gradients were assessed predischarge and recorded. Results: There were 98 (51.5%) males and 92 (48.5%) females in the study cohort. The mean age was 40 +- 14 years. Of the total, 101 (53%) had mitral, 46 (24.2%) had aortic and 43 (22.6%) patients had dual valve replacement. Doppler derived mean gradient was assessed across 144 mitral and 89 aortic St Jude mechanical prosthesis. Doppler derived mean gradient for St Jude mitral prosthesis was 3.5 mm Hg and for St Jude aortic prosthesis was 10.2 mm Hg. Conclusions: The study determines baseline gradients across mitral and aortic St Jude mechanical prosthesis in our population. These can be used as reference gradients to assess St Jude prosthetic valve function in patients who did not have early postoperative doppler assessment. (author)

  12. The reverse shoulder prosthesis: a review of imaging features and complications

    Energy Technology Data Exchange (ETDEWEB)

    McFarland, Edward G.; Sanguanjit, Prakasit; Tasaki, Atsushi [Johns Hopkins University, Department of Orthopedic Surgery, Lutherville, MD (United States); Keyurapan, Ekavit [Mahidol University, Department of Orthopaedic Surgery, Bangkok (Thailand); Fishman, Elliot K.; Fayad, Laura M. [Johns Hopkins Medical Institutions, Johns Hopkins University, Department of Radiology and Radiological Sciences, Baltimore, MD (United States)

    2006-07-15

    The reverse shoulder prosthesis is a prosthesis that has been in clinical use in Europe since 1985 and was approved for use in the United States in 2004. This unique prosthesis has a baseplate attached to the glenoid, which holds a spherical component, while the humeral component includes a polyethylene insert that is flat. This design is the ''reverse'' configuration of that seen with a conventional arthroplasty, in which the spherical component is part of the humeral component. The indications for the reverse prosthesis are: (1) painful arthritis associated with irreparable rotator cuff tears (cuff tear arthropathy), (2) failed hemiarthroplasty with irreparable rotator cuff tears, (3) pseudoparalysis due to massive, irreparable rotator cuff tears, (4) some reconstructions after tumor resection, and (5) some fractures of the shoulder not repairable or reconstructable with other techniques. This prosthesis can produce a significant reduction in pain and some improvement in function for most of the indications mentioned. However, the unique configuration and the challenge of its insertion can result in a high incidence of a wide variety of unusual complications. Some of these complications, such as dislocation of the components, are similar to conventional shoulder replacement. Other complications, such as notching of the scapula and acromial stress fractures, are unique to this prosthesis. (orig.)

  13. The reverse shoulder prosthesis: a review of imaging features and complications

    International Nuclear Information System (INIS)

    McFarland, Edward G.; Sanguanjit, Prakasit; Tasaki, Atsushi; Keyurapan, Ekavit; Fishman, Elliot K.; Fayad, Laura M.

    2006-01-01

    The reverse shoulder prosthesis is a prosthesis that has been in clinical use in Europe since 1985 and was approved for use in the United States in 2004. This unique prosthesis has a baseplate attached to the glenoid, which holds a spherical component, while the humeral component includes a polyethylene insert that is flat. This design is the ''reverse'' configuration of that seen with a conventional arthroplasty, in which the spherical component is part of the humeral component. The indications for the reverse prosthesis are: (1) painful arthritis associated with irreparable rotator cuff tears (cuff tear arthropathy), (2) failed hemiarthroplasty with irreparable rotator cuff tears, (3) pseudoparalysis due to massive, irreparable rotator cuff tears, (4) some reconstructions after tumor resection, and (5) some fractures of the shoulder not repairable or reconstructable with other techniques. This prosthesis can produce a significant reduction in pain and some improvement in function for most of the indications mentioned. However, the unique configuration and the challenge of its insertion can result in a high incidence of a wide variety of unusual complications. Some of these complications, such as dislocation of the components, are similar to conventional shoulder replacement. Other complications, such as notching of the scapula and acromial stress fractures, are unique to this prosthesis. (orig.)

  14. Metal-on-metal hip resurfacings. A radiological perspective

    International Nuclear Information System (INIS)

    Chen, Zhongbo; Pandit, Hemant; Taylor, Adrian; Gill, Harinderjit; Murray, David; Ostlere, Simon

    2011-01-01

    It is important to be aware of the various complications related to resurfacing arthroplasty of the hip (RSA) and the spectrum of findings that may be encountered on imaging. The bone conserving metal-on-metal (MOM) hip resurfacing has become increasingly popular over the last ten years, especially in young and active patients. Initial reports have been encouraging, but long-term outcome is still unknown. Early post operative complications are rare and have been well documented in the literature. Medium and long term complications are less well understood. A rare but important problem seen at this stage is the appearance of a cystic or solid periarticular reactive mass, which occurs predominately in women and usually affects both hips when seen in patients with bilateral RSAs. The following imaging findings are illustrated and their significance discussed; Uncomplicated hip resurfacing arthroplasty, radiolucency around the femoral peg, femoral neck fracture, loosening and infection, suboptimal component position, femoral notching, dislocation, heterotopic ossification, femoral neck thinning and reactive masses. The radiologist should be aware of the normal radiographic appearances and the variety of complications that may occur following RSA and should recommend ultrasound or MRI in patients with an unexplained symptomatic hip and normal radiographs. (orig.)

  15. Association between dental prosthesis need, nutritional status and quality of life of elderly subjects

    DEFF Research Database (Denmark)

    Pillai, Rajath; Mathur, Vijay Prakash; Jain, Veena

    2015-01-01

    clinic were recruited in the study. Mini-nutritional assessment (MNA), geriatric oral health assessment (GOHAI) indices, prosthesis need according to WHO criteria, and prosthesis want was recorded along with age, gender, socioeconomic status and posterior occluding pair. RESULTS: Significant associations......To determine the effect of prosthesis need on nutritional status and oral health-related quality of life (OHrQoL) in elderly and to check the disparity between prosthesis need and prosthesis want in the Indian elderly. METHODS: A total of 946 geriatric participants reporting to a geriatric medicine...

  16. A computer-based biomechanical analysis of the three-dimensional motion of cementless hip prostheses.

    Science.gov (United States)

    Gilbert, J L; Bloomfeld, R S; Lautenschlager, E P; Wixson, R L

    1992-04-01

    A computer-based mathematical technique was developed to measure and completely describe the migration and micromotion of a femoral hip prosthesis relative to the femur. This technique utilized the mechanics of rigid-body motion analysis and apparatus of seven linear displacement transducers to measure and describe the complete three-dimensional motion of the prosthesis during cyclic loading. Computer acquisition of the data and custom analysis software allowed one to calculate the magnitude and direction of the motion of any point of interest on the prostheses from information about the motion of two points on the device. The data were also used to replay the tests using a computer animation technique, which allowed a magnified view of the three-dimensional motion of the prosthesis. This paper describes the mathematical development of the rigid-body motion analysis, the experimental method and apparatus for data collection, the technique used to animate the motion, the sources of error and the effect of the assumptions (rigid bodies) on the results. Selected results of individual test runs of uncemented and cemented prostheses are presented to demonstrate the efficacy of the method. The combined effect of the vibration and electrical noise resulted in a resolution of the system of about 3-5 microns motion for each transducer. Deformation effects appear to contribute about 3-15 microns to the measurement error. This measurement and analysis technique is a very sensitive and powerful means of assessing the effects of different design parameters on the migration and micromotion of total joint prostheses and can be applied to any other case (knee, dental implant) where three-dimensional relative motion between two bodies is important.

  17. Hip fractures in old men

    International Nuclear Information System (INIS)

    Martinez Rondanelli, Alfredo

    2005-01-01

    Describe 289 hip fractures that were admitted at Hospital Universitario del Valle between November 1, 2003 and June 30, 2004. The patients had the first appointment at 2.7 days after the fallen, 60% the patients were women, at he age average were 75 years. In the hospital 228 patients were operated (79%). The surgery was realized in average at the twelve days after than they were admitted at the hospital. The days in the hospital were in average 17.5 days. The index of Katz at the admission was 3.96 and the Parker index was 6.56. The mortality in the hospital was of 30 patients (11%). The following during six months was in 114 patients of the people that were operated; we found loss of initial reduction the hip fracture in 10% and infection in 4%

  18. Dual mobility cups for preventing early hip arthroplasty dislocation in patients at risk: experience in a county hospital

    Directory of Open Access Journals (Sweden)

    Sebastian S. Mukka

    2013-06-01

    Full Text Available Dislocation remains a major concern after hip arthroplasty. We asked whether dual mobility cups (DMC would improve early hip stability in patients with high risk of dislocation. We followed 34 patients (21 females, 13 males treated between 2009 and 2012 with cemented DMC for hip revisions caused recurrent hip prosthetic dislocation or as a primary procedure in patients with high risk of instability. Functional outcome and quality of life were evaluated using Harris Hip Score and EQ-5D respectively. We found that the cemented DMC gave stability in 94%. Seven patients (20% were re-operated due to infection. One patient sustained a periprosthetic fracture. At follow-up (6 to 36 months, mean 18, the mean Harris hip score was 67 (standard deviation: 14 and mean EQ-5D was 0.76 (standard deviation: 0.12. We concluded that treating patients with high risk of dislocation with DMC can give good stability. However, complications such as postoperative infection can be frequent and should be managed carefully.

  19. Diagnosis of prosthetic joint infection with alpha-defensin using a lateral flow device: a multicentre study.

    Science.gov (United States)

    Berger, P; Van Cauter, M; Driesen, R; Neyt, J; Cornu, O; Bellemans, J

    2017-09-01

    The purpose of this current multicentre study is to analyse the presence of alpha-defensin proteins in synovial fluid using the Synovasure lateral flow device and to determine its diagnostic reliability and accuracy compared with the prosthetic joint infection (PJI) criteria produced by the Musculoskeletal Infection Society (MSIS). A cohort of 121 patients comprising 85 total knee arthroplasties and 36 total hip arthroplasties was prospectively evaluated between May 2015 and June 2016 in three different orthopaedic centres. The tests were performed on patients with a chronically painful prosthesis undergoing a joint aspiration in a diagnostic pathway or during revision surgery. Based on the MSIS criteria, 34 patients (28%) would have had a PJI, and 87 patients had no PJI. Testing with the lateral flow device had a sensitivity of 97.1% (95% confidence intervals (CI) 84.5 to 99.9) and a specificity of 96.6% (95% CI 90.3 to 99.2). The positive predictive value was 91.7% (95% CI 77.7% to 98.3), and the negative predictive value was 98.8% (95% CI 93.6 to 99.9). Receiver operator characteristics analysis demonstrated an area under the curve for the Synovasure test of 0.97 (95% CI 0.93 to 1.00). Our findings suggest that the Synovasure test has an excellent diagnostic performance to confirm or reject the diagnosis of a PJI. The results are promising for the care of the painful or problematic knee and hip joint arthroplasty and the test should be considered as part of the diagnostic toolbox for PJIs. Cite this article: Bone Joint J 2017;99-B:1176-82. ©2017 The British Editorial Society of Bone & Joint Surgery.

  20. Smartphone supported upper limb prosthesis

    Directory of Open Access Journals (Sweden)

    Hepp D.

    2015-09-01

    Full Text Available State of the art upper limb prostheses offer up to six active DoFs (degrees of freedom and are controlled using different grip patterns. This low number of DoFs combined with a machine-human-interface which does not provide control over all DoFs separately result in a lack of usability for the patient. The aim of this novel upper limb prosthesis is both offering simplified control possibilities for changing grip patterns depending on the patients’ priorities and the improvement of grasp capability. Design development followed the design process requirements given by the European Medical Device Directive 93/42 ECC and was structured into the topics mechanics, software and drive technology. First user needs were identified by literature research and by patient feedback. Consequently, concepts were evaluated against technical and usability requirements. A first evaluation prototype with one active DoF per finger was manufactured. In a second step a test setup with two active DoF per finger was designed. The prototype is connected to an Android based smartphone application. Two main grip patterns can be preselected in the software application and afterwards changed and used by the EMG signal. Three different control algorithms can be selected: “all-day”, “fine” and “tired muscle”. Further parameters can be adjusted to customize the prosthesis to the patients’ needs. First patient feedback certified the prosthesis an improved level of handling compared to the existing devices. Using the two DoF test setup, the possibilities of finger control with a neural network are evaluated at the moment. In a first user feedback test, the smartphone based software application increased the device usability, e.g. the change within preselected grip patterns and the “tired muscle” algorithm. Although the overall software application was positively rated, the handling of the prosthesis itself needs to be proven within a patient study to be

  1. Perioperative Allogeneic Red Blood-Cell Transfusion Associated with Surgical Site Infection After Total Hip and Knee Arthroplasty.

    Science.gov (United States)

    Everhart, Joshua S; Sojka, John H; Mayerson, Joel L; Glassman, Andrew H; Scharschmidt, Thomas J

    2018-02-21

    Perioperative allogeneic red blood-cell transfusion is a suspected risk factor for surgical site infection (SSI) after total joint arthroplasty (TJA), but the interrelationships among SSI risk, transfusion dose, preoperative anemia, and the presence of coagulopathies have not been well described. Data on SSI within 1 year after surgery as well as on transfusion with blood products within 30 days after surgery were obtained for 6,788 patients who had undergone primary or revision total hip or knee arthroplasty from 2000 to 2011 in a single hospital system. Multivariate logistic regression modeling was used to determine the independent association between allogeneic red blood-cell transfusion and SSI. There was a dose-dependent association between allogeneic red blood-cell transfusion and SSI, with the infection rate increasing as the transfusion dose increased from 1 unit (odds ratio [OR] = 1.97; 95% confidence interval [CI] = 1.38, 2.79; p 3 units (OR = 7.40; CI = 4.91, 11.03; p conservation strategies. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  2. Candida infection of a prosthetic shoulder joint

    Energy Technology Data Exchange (ETDEWEB)

    Lichtman, E.A.

    1983-09-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole.

  3. Effect of silicone gel breast prosthesis on electron and photon dose distributions

    International Nuclear Information System (INIS)

    Krishnan, L.; St George, F.J.; Mansfield, C.M.; Krishnan, E.C.

    1983-01-01

    The effect of a silicone gel breast prosthesis on the absorbed dose distribution of 9-20 MeV electron beams and 1.25-15 MV photon beams was studied. Compared to water measurements, at depths smaller than the practical range of the electron beams, the central axis depth dose values below the prosthesis were lower for all energies by as much as 3.5%. However, at depths near the practical range, the central axis depth dose values for the prosthesis were greater than that of water by as much as 33%. Since this occurs near the end of the electron range, the resultant difference may not be clinically significant. Results of the effect of breast prosthesis on photon depth dose distributions reveal that no clinically significant perturbation is produced by the breast prosthesis using Co-60, 6- and 15-MV radiations

  4. Fabrication of custom made ocular prosthesis with three different ...

    African Journals Online (AJOL)

    Loss of eye has a bad effect on the psychology of the patient. Eye prosthesis is fabricated to regain the patient's confidence by meticulous replacement of the missing eye. Immediate fitting of an anophthalmic socket with an artificial eye may not always be possible, and a delayed prosthesis delivery may result in settling and ...

  5. HIP JOINT AND HIP ENDOPROSTHESIS BIOMECHANICS

    OpenAIRE

    Jakub Gryka

    2017-01-01

    This article contains a description of the basic issues related to anatomy, loading of hip joint and its endoprosthesis research methods. The methods of testing and simulating hip joint loads, factors that influence the selection of parameters during the design of prostheses, typical solutions to engineering problems related to this topic are presented. The article concludes with short summary of the finite element method for the design of hip replacements.

  6. Simplified technique for orbital prosthesis fabrication: a clinical report.

    Science.gov (United States)

    Veerareddy, Chandrika; Nair, K Chandrasekharan; Reddy, G Ramaswamy

    2012-10-01

    Loss of orbital content can cause functional impairment, disfigurement of the face, and psychological distress. Rehabilitation of an orbital defect is a complex task, and if reconstruction by plastic surgery is not possible or not desired by the patient, the defect can be rehabilitated by an orbital prosthesis. The prosthetic rehabilitation in such cases depends on the precisely retained, user-friendly removable maxillofacial prosthesis. Many times, making an impression of the orbital area with an accurate record of surface details can be a difficult procedure. The critical areas are making a facial moulage, mold preparation, and attaching the retention device, particularly when eyeglass frames are used. This case focuses on these hindrance factors. A simple basket was used for the impression tray to obtain the facial moulage. A putty mold was used, and attachment of the prosthesis to a retention device was accomplished with positional distance. This method proves to be an economical and simple way of making an orbital prosthesis. © 2012 by the American College of Prosthodontists.

  7. Does Preoperative Antimicrobial Prophylaxis Influence the Diagnostic Potential of Periprosthetic Tissues in Hip or Knee Infections?

    Science.gov (United States)

    Bedenčič, Klemen; Kavčič, Martina; Faganeli, Nataša; Mihalič, Rene; Mavčič, Blaž; Dolenc, Jožica; Bajc, Zlatka; Trebše, Rihard

    2016-01-01

    Undiagnosed low-grade prosthetic joint infections (PJI) are recognized as an important reason for early failure of presumably aseptic revisions. Preoperatively administered antimicrobial prophylaxis reduces the incidence of PJI but it may reduce the sensitivity of microbiologic periprosthetic tissue cultures and consequently increase the incidence of undiagnosed septic prosthetic joint failures, which can lead to catastrophic serial revisions. We wished to determine whether administration of preoperative antibiotics decreases the likelihood of diagnosing PJI in patients undergoing revision hip or knee arthroplasty in whom infection is suspected. We prospectively enrolled and evaluated 40 patients (29 with THAs and 11 with TKAs) who met the following inclusion criteria: older than 18 years, with suspected PJI of unknown cause, undergoing surgical revision. After arthrotomy, three tissue samples were obtained for microbiologic analysis and diagnosis, and antimicrobial prophylaxis (cefazolin 2 g intravenously) then was administered. Later during the procedure, but before débridement and irrigation, the second set of three tissue samples was obtained from the same surgical area and was cultured. Tissue concentration of prophylactic antibiotic was verified with the second set of samples. A positive culture result was defined as one or more positive cultures (growth on agar at or before 14 days). We then compared the yield on the microbiologic cultures obtained before administration of antibiotics with the yield on the cultures obtained after antibiotics were administered. An a priori analysis was performed; with the numbers available, we had 98% power to detect a difference in diagnostic sensitivity of 33%. With the numbers available, we found no difference in the likelihood that an infection would be diagnosed between the samples obtained before and after administration of antimicrobial prophylaxis (odds ratio [OR] for positive microbial culture = 0.99; 95% CI, 0

  8. [Rehabilitation by hollow obturator prosthesis immediately after total maxillectomy for malignant tumor].

    Science.gov (United States)

    Li, Xiao-ye; Yan, Ai-hui; Hao, Shuai; Li, Wei; Jiang, Xue-jun; Lu, Li; Qin, Xing-jun; Yan, Hai-xin

    2011-05-01

    The feasibility and clinical effects of hollow obturator prosthesis for the repair of maxillofacial defect immediately after maxillectomy for cancer were assessed. Thirteen patients with T3-4aN0M0 maxillary neoplasm were treated by the prostheses immediately after maxillectomy. According to the 3D-CT reconstruction of nasal sinus, the 3D stereoscopic prototype was constructed before the surgery. Simulating surgery with Surgicare 5.0 software and then the prosthesis 3D stereoscopic model was shaped. The prosthesis was made quickly and precisely with methacrylate resins according to the model and the print mold before surgery, with supplementary tooth at the bottom of prosthesis. In the surgery, the prosthesis was installed instantly after maxillectomy. The patients were followed up at 1, 3 and 6 month after the surgery, respectively. The facial features and the pronunciation clarity were examined and the questionnaires were carried out in the patients, with comparation by paired t-test. The hollow obturator prosthesis would be replaced by permanent prosthesis made of methacrylate resins at 6 month after the surgery. The hollow obturator prostheses were installed accurately and maxillofacial defects were repaired immediately after maxillectomy in the 13 patients. Postoperative follow-up showed there were significant differences in eyeball sagging (t = 4.67, P maxillectomy can improve survival quality of patient.

  9. FIVE YEAR OUTCOMES OF CERAMIC-ОN-CERAMIC AND CERAMIC-ОN-POLYETHYLENE BEARINGS IN HIP JOINT REPLACEMENT

    Directory of Open Access Journals (Sweden)

    V. Yu. Murylev

    2017-01-01

    Full Text Available In view of the increasing number of hip joint replacement volume there remains the key issue of improving prosthesis survivorship which directly depends on the friction couple. Material and methods. The authors have analyzed five year outcomes of two bearing types (head and insert used in hip replacement: ceramic-on-ceramic (CoC in 324 patients and ceramic-on-polyethylene (CoP in 300 patients. Totally 550 patients were operated in the period starting 2010 till 2014, including 74 patients underwent bilateral hip replacement. The authors divided patients based on gender and also into three age groups: 20-40, 41-60 and 61-80 years old. The largest group comprised 156 women aged 41-60 years (28.4%. Additional grouping of patients was made based on gender, age and bearing diameter.36 mm diameter bearing was characterized of the most frequent use. Functional outcomes were assessed by Harris Hip Score. Statistical analysis was made with Statistica 10 software. Statistical significant was observed at p<0.05.Results.28 mm diameter bearing were rarely (19.5% applied and mainly in women which is related to need for use of smaller acetabulum components and inability to implant a larger insert.36 mm diameter bearing were used most frequently, CoC articulation of36 mm was used in men in 34% of cases and in women – in 18.12% of cases.40 mm articulations were implanted in women two times less than in men which is related to a smaller diameter of acetabulum in women. Generally, CoC bearings were implanted more often in men which can be explained by a bigger social demand as well as a higher anti-luxation stability of large diameter bearings. Dislocations of implants occurred in 5 (0.91% patients: in 4 patients with CoP bearingand in one patient with CoC articulation. Four revision procedures (0.64% were made due to deep periprosthetic infection: two surgeries in each group. Harris Hip Score evaluation in CoC group demonstrated excellent and good outcomes in

  10. Failure of the first step of two-stage revision due to polymicrobial prosthetic joint infection of the hip.

    Science.gov (United States)

    Bozhkova, Svetlana; Tikhilov, Rashid; Labutin, Dmitry; Denisov, Alexey; Shubnyakov, Igor; Razorenov, Vadim; Artyukh, Vasilii; Rukina, Anna

    2016-12-01

    The unsuccessful treatment of prosthetic joint infection (PJI) with two-stage revision leads to infection recurrence. The objectives of the study were to assess the clinical and demographic characteristics of patients with polymicrobial PJI, and to evaluate the role of the microbial profile involved in PJI in the risk of infection recurrence after the first step of two-stage revision surgery. A retrospective analysis of 189 cases of culture-positive PJI following total hip replacement over a 5-year period was performed. The demographic characteristics of patients, clinical symptoms, microbiology cultures of intraoperative biopsies, laboratory values of C-reactive protein (CRP), white blood cell count and erythrocyte sedimentation rate were analyzed. Patients were divided into two groups-135 with monomicrobial and 54 with polymicrobial infection. Of all patients, 68.9 % in the monomicrobial and 83.3 % in the polymicrobial group had a body mass index >25 kg/m 2 (p = 0.05). The median CRP values were 5.7 mg/L (IQR 4.0-10.0 mg/L) in the monomicrobial compared to 8.8 mg/L (IQR 5.0-27 mg/L) in the polymicrobial group (p = 0.01). The percentage of successful outcomes was 27.8 % in patients with microbial associations (p infection recurrence (OR 4.4; 95 % CI 1.18-16.37; p = 0.03). Overweight and obese patients or those with elevated CRP had a greater risk of polymicrobial PJI. They were predisposed to recurrence of infection after the first step of two-stage revision. An unsuccessful outcome was more likely in cases with polymicrobial infection compared to those with monomicrobial infection. In addition, the presence of multidrug-resistant strains of Gram-negative bacteria substantially increased the risk of PJI treatment being unsuccessful. Level III, therapeutic study.

  11. Identification of the Cause of the Stem Neck Fracture in the Hip Joint Endoprosthesis

    Directory of Open Access Journals (Sweden)

    Ryniewicz A.M.

    2018-02-01

    Full Text Available Endoprosthesis stem fractures are among the rarest complications that occur after hip joint arthroplasty. The aim of this paper is to evaluate the causes of the fractures of the Aura II stem neck, which is an element of an endoprosthesis implanted in a patient. In order to achieve it, a radiogram was evaluated, the FEM analysis was carried out for the hip joint replaced using the Aura II prosthesis and scanning tests as well as a chemical analysis were performed for the focus of fatigue. The tests performed indicate that the most probable causes leading to the fatigue fracture of the Aura II stem under examination were material defects in the process of casting and forging (forging the material with delamination and the presence of brittle oxides and carbides that resulted in a significant reduction of strength and resistance to corrosion. In the light of an unprecedented stem neck fracture, this information should be an indication for non-destructive tests of ready-made stems aiming to discover the material and technological defects that may arise in the process of casting and drop forging.

  12. Analysis of the mechanical behavior of the Nijdam voice prosthesis

    NARCIS (Netherlands)

    Verkerke, GJ; deVries, MP; Schutte, HK; vandenHoogen, FJA; Rakhorst, G

    1997-01-01

    The valveless Nijdam prosthesis is a new voice prosthesis for laryngectomized patients using tracheoesophageal speech. An ''umbrella-like hat'' covers the esophageal side of the tracheoesophageal fistula and is deformed during speech by air pressure. To decrease pressure loss during speech, a good

  13. Custom-made silicone hand prosthesis: A case study.

    Science.gov (United States)

    Nayak, S; Lenka, P K; Equebal, A; Biswas, A

    2016-09-01

    Up to now, a cosmetic glove was the most common method for managing transmetacarpal (TMC) and carpometacarpal (CMC) amputations, but it is devoid of markings and body color. At this amputation level, it is very difficult to fit a functional prosthesis because of the short available length, unsightly shape, grafted skin, contracture and lack of functional prosthetic options. A 30-year-old male came to our clinic with amputation at the 1st to 4th carpometacarpal level and a 5th metacarpal that was projected laterally and fused with the carpal bone. The stump had grafted skin, redness, and an unhealed suture line. He complained of pain projected over the metacarpal and suture area. The clinical team members decided to fabricate a custom-made silicone hand prosthesis to accommodate the stump, protect the grafted skin, improve the hand's appearance and provide some passive function. The custom silicone hand prosthesis was fabricated with modified flexible wires to provide passive interphalangeal movement. Basic training, care and maintenance instructions for the prosthesis were given to the patient. The silicone hand prosthesis was able to restore the appearance of the lost digits and provide some passive function. His pain (VAS score) was reduced. Improvement in activities of daily living was found in the DASH questionnaire and Jebsen-Taylor Hand Function test. A silicone glove is a good option for more distal amputations, as it can accommodate any deformity, protect the skin, enhance the appearance and provide functional assistance. This case study provides a simple method to get passively movable fingers after proximal hand amputation. Copyright © 2016. Published by Elsevier Masson SAS.

  14. Fixation of total hip components in rheumatoid arthritis and arthrosis. A radiographic, roentgen stereophotogrammetric, densitometric and histomorphometric study

    International Nuclear Information System (INIS)

    Oensten, I.

    1994-01-01

    The radiographic survival of the Charnley prosthesis was studied in two retrospective, matched-pair cohorts of rheumatoid arthritis (RA) and arthrosis (OA) patients. In RA, the 7-year radiographic socket survival improved from 87% to 96% after the introduction of flanged sockets, bone transplants in cases of acetabular protrusion and the rejection of the pilot hole technique. In OA the 10-year radiographic socket survival was 95%. In both groups the 7-year radiographic stem survival improved from 80% to 96% following the introduction of the new cementing technique. Migration of the Charnley prosthesis in the first two years was evaluated by roentgen stereophotogrammetric analysis (RSA) in RA and OA patients, and related to the histomorphometric characteristics of trabecular bone in the acetabulum and the femur. In RA, sockets migrated six times more in the proximal direction as compared with OA; there was no difference in migration in other directions. Stem fixation was equally secure in RA and OA. RA cases had more osteoid in both the femur and the acetabulum, but the amount of osteoid was not correlated with the degree of migration. The bone mineral content (BMC) of RA and OA hips was assessed by dual photone roentgen absorptiometry prior to hip replacement. Patients with RA had 20% less BMC than those with OA but there were no signs of a relative peri-acetabular deficit. In two randomized trials of 81 OA patients, migration of the uncemented, Harris-Galante type I socket was evaluated by RSA and compared with Charnley sockets. After a minimum follow-up of 2 years, no difference in migration between the two socket designs was found. 98 refs, 18 figs, 2 tabs

  15. Fixation of total hip components in rheumatoid arthritis and arthrosis. A radiographic, roentgen stereophotogrammetric, densitometric and histomorphometric study

    Energy Technology Data Exchange (ETDEWEB)

    Oensten, I.

    1994-10-14

    The radiographic survival of the Charnley prosthesis was studied in two retrospective, matched-pair cohorts of rheumatoid arthritis (RA) and arthrosis (OA) patients. In RA, the 7-year radiographic socket survival improved from 87% to 96% after the introduction of flanged sockets, bone transplants in cases of acetabular protrusion and the rejection of the pilot hole technique. In OA the 10-year radiographic socket survival was 95%. In both groups the 7-year radiographic stem survival improved from 80% to 96% following the introduction of the new cementing technique. Migration of the Charnley prosthesis in the first two years was evaluated by roentgen stereophotogrammetric analysis (RSA) in RA and OA patients, and related to the histomorphometric characteristics of trabecular bone in the acetabulum and the femur. In RA, sockets migrated six times more in the proximal direction as compared with OA; there was no difference in migration in other directions. Stem fixation was equally secure in RA and OA. RA cases had more osteoid in both the femur and the acetabulum, but the amount of osteoid was not correlated with the degree of migration. The bone mineral content (BMC) of RA and OA hips was assessed by dual photone roentgen absorptiometry prior to hip replacement. Patients with RA had 20% less BMC than those with OA but there were no signs of a relative peri-acetabular deficit. In two randomized trials of 81 OA patients, migration of the uncemented, Harris-Galante type I socket was evaluated by RSA and compared with Charnley sockets. After a minimum follow-up of 2 years, no difference in migration between the two socket designs was found. 98 refs, 18 figs, 2 tabs.

  16. Hip Fracture

    Science.gov (United States)

    ... hip fractures in people of all ages. In older adults, a hip fracture is most often a result of a fall from a standing height. In people with very weak bones, a hip fracture can occur simply by standing on the leg and twisting. Risk factors The rate of hip fractures increases substantially with ...

  17. Candida infection of a prosthetic shoulder joint

    International Nuclear Information System (INIS)

    Lichtman, E.A.; Veterans Administration Medical Center, New York

    1983-01-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole. (orig.)

  18. Rate and Risk Factors for Periprosthetic Joint Infection Among 36,494 Primary Total Hip Arthroplasties.

    Science.gov (United States)

    Triantafyllopoulos, Georgios K; Soranoglou, Vasileios G; Memtsoudis, Stavros G; Sculco, Thomas P; Poultsides, Lazaros A

    2018-04-01

    As periprosthetic joint infections (PJIs) can have tremendous health and socioeconomic implications, recognizing patients at risk before surgery is of great importance. Therefore, we sought to determine the rate of and risk factors for deep PJI in patients undergoing primary total hip arthroplasty (THA). Clinical characteristics of patients treated with primary THA between January 1999 and December 2013 were retrospectively reviewed. These included patient demographics, comorbidities (including the Charlson/Deyo comorbidity index), length of stay, primary diagnosis, total/allogeneic transfusion rate, and in-hospital complications, which were grouped into local and systemic (minor and major). We determined the overall deep PJI rate, as well as the rates for early-onset (occurring within 2 years after index surgery) and late-onset PJI (occurring more than 2 years after surgery). A Cox proportional hazards regression model was constructed to identify risk factors for developing deep PJI. Significance level was set at 0.05. A deep PJI developed in 154 of 36,494 primary THAs (0.4%) during the study period. Early onset PJI was found in 122 patients (0.3%), whereas late PJI occurred in 32 patients (0.1%). Obesity, coronary artery disease, and pulmonary hypertension were identified as independent risk factors for deep PJI after primary THA. The rate of deep PJIs of the hip is relatively low, with the majority occurring within 2 years after THA. If the optimization of modifiable risk factors before THA can reduce the rate of this complication remains unknown, but should be attempted as part of good practice. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Mastication improvement after partial implant-supported prosthesis use.

    Science.gov (United States)

    Gonçalves, T M S V; Campos, C H; Gonçalves, G M; de Moraes, M; Rodrigues Garcia, R C M

    2013-12-01

    Partially edentulous patients may be rehabilitated by the placement of removable dental prostheses, implant-supported removable dental prostheses, or partial implant fixed dental prostheses. However, it is unclear the impact of each prosthesis type over the masticatory aspects, which represents the objective of this paired clinical trial. Twelve patients sequentially received and used each of these 3 prosthesis types for 2 months, after which maximum bite force was assessed by a strain sensor and food comminution index was determined with the sieving method. Masseter and temporal muscle thicknesses during rest and maximal clenching were also evaluated by ultrasonography. Each maxillary arch received a new complete denture that was used throughout the study. Data were analyzed by analysis of variance for repeated measures, followed by the Tukey test (p mastication, and the magnitude of this effect was related to prosthesis type.

  20. Short-term clinical experience with hip resurfacing arthroplasty.

    Science.gov (United States)

    Cieliński, Łukasz; Kusz, Damian; Wojciechowski, Piotr; Dziuba, Anna

    2007-01-01

    This paper discusses the authors' experience with hip resurfacing arthroplasty. Although introduced many years ago, the method did not gain wide popularity because of poor long-term outcomes. At present, owing to the introduction of metal-on-metal bearings and hybrid fixation techniques, short- and mid-term results are very good and encourage wider use of this technique, especially in the younger and more active patients whose results with standard total hip replacements would be unsatisfactory. We performed 13 hip resurfacing arthroplasties at our institution between August 1, 2005, and May 1, 2006. Twelve patients reported for the scheduled follow-up and were included in the study. Treatment outcomes were assessed according to the Harris Hip Score. The short-term outcomes of hip resurfacing arthroplasties are encouraging. In the study group there were no intraoperative complications, infections, peripheral nerve palsy, hip dislocations or clinically overt vein thrombosis. All of the patients reported complete or major pain relief. Clinical assessment according to the Harris Hip Score revealed improvement from an average of 57.7 (20.1) points preoperatively to an average of 87.7 (12) points after the surgery. Crutches were used for a maximum of 6 weeks postoperatively. All of the patients are currently able to walk without crutches with full weight-bearing. 1) Hip resurfacing arthroplasty seems to be an advisable method of operative management of younger, active patients, in whom standard THR would be associated with a high risk of failure; it allows THR to be postponed and carried out as a revision surgery with the acetabular component already in place. 2) Despite the good short- and mid-term results, the utility of this method should be evaluated with caution due to the lack of adequate long-term follow-up data.