WorldWideScience

Sample records for industrial roof coatings

  1. Development of a Long-Life-Cycle, Highly Water-Resistant Solar Reflective Retrofit Roof Coating

    Energy Technology Data Exchange (ETDEWEB)

    Polyzos, Georgios [ORNL; Hunter, Scott Robert [ORNL; Sharma, Jaswinder K [ORNL; Cheng, Mengdawn [ORNL; Chen, Sharon S [Lawrence Berkeley National Laboratory (LBNL); Demarest, Victoria [Dow Chemical Company; Fabiny, William [Dow Chemical Company; Destaillats, Hugo [Lawrence Berkeley National Laboratory (LBNL); Levinson, Ronnen [Lawrence Berkeley National Laboratory (LBNL)

    2016-03-04

    Highly water-resistant and solar-reflective coatings for low-slope roofs are potentially among the most economical retrofit approaches to thermal management of the building envelope. Therefore, they represent a key building technology research program within the Department of Energy. Research efforts in industry and the Department of Energy are currently under way to increase long-term solar reflectance on a number of fronts. These include new polymer coatings technologies to provide longer-lasting solar reflectivity and improved test methodologies to predict long-term soiling and microbial performance. The focus on long-term improvements in soiling and microbial resistance for maximum reflectance does not address the single most important factor impacting the long-term sustainability of low-slope roof coatings: excellent water resistance. The hydrophobic character of asphaltic roof products makes them uniquely suitable for water resistance, but their low albedo and poor exterior durability are disadvantages. A reflective coating that maintains very high water resistance with increased long-term resistance to soiling and microbial activity would provide additional energy savings and extend roof service life.

  2. 40 CFR Table 2 of Subpart Aaaaaaa... - Emission Limits for Asphalt Roofing Manufacturing (Coating) Operations

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Emission Limits for Asphalt Roofing Manufacturing (Coating) Operations 2 Table 2 of Subpart AAAAAAA of Part 63 Protection of Environment... AAAAAAA of Part 63—Emission Limits for Asphalt Roofing Manufacturing (Coating) Operations For * * * 1...

  3. Greenbacks from green roofs: forging a new industry in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Peck, S. W.; Callaghan, C. [Peck and Associates, Toronto, ON (Canada); Bass, B. [Environment Canada, Toronto, ON (Canada); Kuhn, M. [Toronto, ON (Canada)

    1999-03-01

    This report provides a comprehensive review of the qualitative and quantitative benefits of green roof and vertical garden technologies, explains the nature of roof greening and green roof systems, examines the barriers to their more rapid diffusion into Canadian markets, and makes recommendations as to how how these barriers may be overcome. Two basic types of green roof systems, extensive and intensive, are identified. Extensive green roofs are characterized by their low weight, low capital cost and low maintenance. Intensive green roofs, by contrast, are heavier, more costly to establish, require intensive planting and higher maintenance. Both types of green roofs may be further subdivided into accessible or inaccessible. Accessible green roofs are flat, outdoor open spaces intended for use as gardens or terraces, while inaccessible roofs are only accessible for periodic maintenance. 'Vertical gardens' are a type of extensive green roof, characterized by the growing of plants on or up against the facade of buildings. The many benefits of green roof or vertical garden technologies include energy cost savings due to increased insulation and improved protection of the roof membrane, air quality improvements, new employment opportunities for a wide range of people including suppliers of roof membranes and related products, and social benefits such as improved aesthetics, health and horticultural therapy. Barriers to diffusion in Canada have been identified as lack of awareness, lack of incentives to implement, cost implications, lack of technical standards, few existing examples and risks associated with uncertainty. The recommendations to overcome market barriers are intended to address these barriers, i.e. they call for increased efforts to generate awareness through addressing the knowledge availability issue, and through high profile demonstration projects, government-sponsored technology diffusion, financial incentives to overcome cost-based barriers

  4. Coatings for transport industry

    Directory of Open Access Journals (Sweden)

    Krzysztof LUKASZKOWICZ

    2014-09-01

    Full Text Available The investigations concerned structural analysis, as well as mechanical properties and wear resistant of MeN/DLC double-layer coating deposited by hybrid PVD/PACVD method. In sliding dry friction conditions, after the break-in time, the friction coefficient for the investigated elements is set in the range between 0.03-0.06.

  5. Electron beam-curing coating for pressed cement roof tiles with high-build and excellent durability

    International Nuclear Information System (INIS)

    Maruyama, Tsutomu; Kiyata, Hiroaki

    1979-01-01

    Thick slate has expanded the demand steadily and spread to whole Japan except the northernmost part as a roof material, because it deals with rain water well, its strength, coldness resistance and endurance are excellent, and it can be worked easily. The ornamental finishing by urethane coating is not satisfactory in view of the improvement of productivity and the measures to pollution as well as the design and color. In order to meet this background, new coating has been sought, and electron beam-curing coating seems to be most suitable to cement roof tiles. The history and the present state of cement roof tiles are explained. About 700 tons/month of the coating for cement roof tiles is used at present, and acryl resin coating occupies about 75%, while urethane resin coating is used in Kyushu relatively more. The urethane coating is applied in shops by electrostatic coating, but the acryl coating is mostly applied in sites after tiling over. Electron beam curing used electron beam of 200 keV, and polymerization starts from the radicals formed through ionization, excitation and neutralization. The features of electron beam-curing coating are good adhesion to roof tiles, keeping luster and endurance to discoloration, strong film and feeling like porcelain, drying at normal temperature, productivity and economy. (J.P.N.)

  6. Development of Clay Tile Coatings for Steep-Sloped Cool Roofs

    Directory of Open Access Journals (Sweden)

    Lucia Brinchi

    2013-07-01

    Full Text Available Most of the pitched roofs of existing buildings in Europe are covered by non-white roofing products, e.g., clay tiles. Typical, cost effective, cool roof solutions are not applicable to these buildings due to important constraints deriving from: (i the owners of homes with roofs visible from the ground level; (ii the regulation about the preservation of the historic architecture and the minimization of the visual environment impact, in particular in historic centers. In this perspective, the present paper deals with the development of high reflective coatings with the purpose to elaborate “cool” tiles with the same visual appearance of traditional tiles for application to historic buildings. Integrated experimental analyses of reflectance, emittance, and superficial temperature were carried out. Deep analysis of the reflectance spectra is undertaken to evaluate the effect of different mineral pigments, binders, and an engobe basecoat. Two tile typologies are investigated: substrate-basecoat-topcoat three-layer tile and substrate-topcoat two-layer tile. The main results show that the developed coatings are able to increase the overall solar reflectance by more than 20% with acceptable visual appearance, suitable for application in historic buildings. Additionally, the effect of a substrate engobe layer allows some further contribution to the increase of the overall reflectance characteristics.

  7. Analysis of Cool Roof Coatings for Residential Demand Side Management in Tropical Australia

    Directory of Open Access Journals (Sweden)

    Wendy Miller

    2015-06-01

    Full Text Available Cool roof coatings have a beneficial impact on reducing the heat load of a range of building types, resulting in reduced cooling energy loads. This study seeks to understand the extent to which cool roof coatings could be used as a residential demand side management (DSM strategy for retrofitting existing housing in a constrained network area in tropical Australia where peak electrical demand is heavily influenced by residential cooling loads. In particular this study seeks to determine whether simulation software used for building regulation purposes can provide networks with the ‘impact certainty’ required by their DSM principles. The building simulation method is supported by a field experiment. Both numerical and experimental data confirm reductions in total consumption (kWh and energy demand (kW. The nature of the regulated simulation software, combined with the diverse nature of residential buildings and their patterns of occupancy, however, mean that simulated results cannot be extrapolated to quantify benefits to a broader distribution network. The study suggests that building data gained from regulatory simulations could be a useful guide for potential impacts of widespread application of cool roof coatings in this region. The practical realization of these positive impacts, however, would require changes to the current business model for the evaluation of DSM strategies. The study provides seven key recommendations that encourage distribution networks to think beyond their infrastructure boundaries, recognising that the broader energy system also includes buildings, appliances and people.

  8. Industrial Coatings at Extreme Conditions

    DEFF Research Database (Denmark)

    Subramanian, Srinath; Pérez Hornero, Clara; Pedersen, Lars Thorslund

    With the gradual depletion of oil wells operable at relatively lower temperatures and pressures, the upstream oil industry relies on High Pressure High Temperature (HPHT) wells to source crude oil and gas. HPHT well extraction and processing require anticorrosive coatings applied on substrates...

  9. Integration of thermal insulation coating and moving-air-cavity in a cool roof system for attic temperature reduction

    International Nuclear Information System (INIS)

    Yew, M.C.; Ramli Sulong, N.H.; Chong, W.T.; Poh, S.C.; Ang, B.C.; Tan, K.H.

    2013-01-01

    Highlights: • A novel integrated cool roof system for attic temperature reduction is introduced. • 13 °C temperature reduction achieved due to its efficient heat transfer mechanism. • Aluminium tube cavity of the roof is able to reduce the attic temperature. • This positive result is due to its efficient heat reflection and hot air rejection. • Thermal insulation coating incorporates the usage of eggshell waste as bio-filler. - Abstract: Cool roof systems play a significant role in enhancing the comfort level of occupants by reducing the attic temperature of the building. Heat transmission through the roof can be reduced by applying thermal insulation coating (TIC) on the roof and/or installing insulation under the roof of the attic. This paper focuses on a TIC integrated with a series of aluminium tubes that are installed on the underside of the metal roof. In this study, the recycled aluminium cans were arranged into tubes that act as a moving-air-cavity (MAC). The TIC was formulated using titanium dioxide pigment with chicken eggshell (CES) waste as bio-filler bound together by a polyurethane resin binder. The thermal conductivity of the thermal insulation paint was measured using KD2 Pro Thermal Properties Analyzer. Four types of cool roof systems were designed and the performances were evaluated. The experimental works were carried out indoors by using halogen light bulbs followed by comparison of the roof and attic temperatures. The temperature of the surrounding air during testing was approximately 27.5 °C. The cool roof that incorporated both TIC and MAC with opened attic inlet showed a significant improvement with a reduction of up to 13 °C (from 42.4 °C to 29.6 °C) in the attic temperature compared to the conventional roof system. The significant difference in the results is due to the low thermal conductivity of the thermal insulation paint (0.107 W/mK) as well as the usage of aluminium tubes in the roof cavity that was able to transfer

  10. Development of Clay Tile Coatings for Steep-Sloped Cool Roofs

    OpenAIRE

    Pisello, Anna; Cotana, Franco; Nicolini, Andrea; Brinchi, Lucia

    2013-01-01

    Most of the pitched roofs of existing buildings in Europe are covered by non-white roofing products, e.g., clay tiles. Typical, cost effective, cool roof solutions are not applicable to these buildings due to important constraints deriving from: (i) the owners of homes with roofs visible from the ground level; (ii) the regulation about the preservation of the historic architecture and the minimization of the visual environment impact, in particular in historic centers. In this perspective, th...

  11. Effects of Wastes from the Brewing Industry in Lightweight Aggregates Manufactured with Clay for Green Roofs

    Science.gov (United States)

    Farías, Romina D.; Martínez García, Carmen; Cotes Palomino, Teresa; Martínez Arellano, Myriam

    2017-01-01

    This study investigates the effects of sieved wastes generated from the brewing industry on lightweight aggregates manufactured with clay. Sludge from a wastewater treatment plant, bagasse and diatomaceous earth were used to obtain the samples. These wastes are usually dumped in landfills, but the current increase in restrictions on dumping and interest in improving the environment make our proposal for gaining value from these wastes a significant contribution. Laboratory tests show that the new aggregate has low bulk density and increased water absorption and porosity. The thermographic camera results provide evidence that new aggregates have significant insulating properties and are suitable for use on green roofs. PMID:28772892

  12. Effects of Wastes from the Brewing Industry in Lightweight Aggregates Manufactured with Clay for Green Roofs

    Directory of Open Access Journals (Sweden)

    Romina D. Farías

    2017-05-01

    Full Text Available This study investigates the effects of sieved wastes generated from the brewing industry on lightweight aggregates manufactured with clay. Sludge from a wastewater treatment plant, bagasse and diatomaceous earth were used to obtain the samples. These wastes are usually dumped in landfills, but the current increase in restrictions on dumping and interest in improving the environment make our proposal for gaining value from these wastes a significant contribution. Laboratory tests show that the new aggregate has low bulk density and increased water absorption and porosity. The thermographic camera results provide evidence that new aggregates have significant insulating properties and are suitable for use on green roofs.

  13. Waterborne UV coating for industrial applications

    International Nuclear Information System (INIS)

    Bhattacharya, I.N.

    2007-01-01

    (Full Text): Solvent borne industrial coatings are being replaced by environment friendly coatings like Ultra Violet (UV) or Electron Beam (Eb) cured coatings, Powder coatings and Waterborne coatings. Waterborne systems enjoy the biggest share from this shift. UV and EB coatings provide the advantages of instant cure at room temperature, high scratch and abrasion resistance combined with excellent chemical resistance. Polyurethane (PU) chemistry is the dominant chemistry in Industrial coatings as they provide a very high level of performance. Most PU coatings are solvent based 2-component systems comprising of a resin and a cross linker. Polyurethane dispersions (PUD) in water in single pack are available but mainly addresses the Do It Yourself (DIY) market because of their slow drying speeds. Performance of PUD in most cases is inferior to solvent borne 2-component PU systems.Therefore the combination of PU dispersion and UV/EB curable technology has led to new innovative waterborne polymers called UV curable polyurethane dispersions (UVPUD). UVPUD are zero VOC systems as they are coalescent free. They are higher in molecular weight than standard UV curable products resulting in lower shrinkage coatings and provide good adhesion to substrates. Their low-viscosity makes them suitable for application by spray, curtain coater and even roller coater, without having to use monomers. UVPUD display superior chemical and mechanical properties necessary to protect high quality surface from the challenging usage conditions. UVPUD resins are therefore tailor-made to address performance needs like excellence in outdoor durability, scratch resistance, stain resistance, adhesion etc. UVPUD technology is now growing rapidly in industrial coatings for applications such as resilient flooring, wooden parquet flooring, automotive interior plastics, mobile phones etc. (Author)

  14. A comparative analysis of selected parameters of roofing used in the Polish construction industry

    Directory of Open Access Journals (Sweden)

    Radziszewska-Zielina Elżbieta

    2014-06-01

    Full Text Available Roofing is an important element in the construction of the roof. It is also one of the essential elements of the whole building. The choice of roofing should depend on technical parameters that affect the quality of the materials used and the price. The present paper is a comparative analysis of the properties of five roofing materials selected as examples with respect to twelve parameters. As can be seen from the comparative analysis of the roofing parameters, roofing tile is by far the best material, receiving the highest score in the ranking

  15. Coating technologies in the nuclear industry

    International Nuclear Information System (INIS)

    Kaae, J.L.

    1993-01-01

    Metallic, ceramic, and organic coatings are so commonly used in modern industry that virtually everyone can name several applications in which coatings are employed. Thus, it is no surprise that coating technologies are widely employed in the nuclear industry. Some of these technologies utilize processes that are mature and well developed, and others utilize processes that are new and state of the art. In this paper, five generic coating processes that include almost all vapor deposition processes are described, and then applications of each of these processes for deposition of specific materials in nuclear applications are described. These latter selections, of course, are very subjective, and others will be able to name other applications. Because of their wide range of application, coating technologies are considered to be national critical technologies. The generic coating processes that cover almost all vapor deposition technologies are as follows: (1) stationary substrate chemical vapor deposition; (2) fluidized bed chemical vapor deposition; (3) plasma-assisted chemical deposition; (4) sputtering; (5) evaporation

  16. Detection Of Moisture In Commercial And Industrial Built-Up Roofing Systems

    Science.gov (United States)

    Sopko, Victor

    1982-03-01

    The roof has always been one of the most important portions of a building envelope. It is, however, one of the most overlooked areas with respect to building maintenance. As long as the roof is not leaking into the building, it is thought to be functioning properly. This is an erroneous assumption as many problems occur long before they are evident as leaks into the building. Early location and repair of roof problems can mean the difference between a roof which must be completely torn off and replaced and one which will give years of service to the building owner.

  17. Evaluation and Optimization of a Traditional North-Light Roof on Industrial Plant Energy Consumption

    Energy Technology Data Exchange (ETDEWEB)

    Adriaenssens, Sigrid [Form-Finding Lab, Department of Civil and Environmental Engineering, School of Engineering and Applied Science, Princeton Univ., NJ (United States); Hao Liu [Center for Intelligent and Networked Systems, Department of Automation, Tsinghua National Laboratory for Information Science and Technology, Tsinghua University, Beijing (China); Wahed, Miriam [Form-Finding Lab, Department of Civil and Environmental Engineering, School of Engineering and Applied Science, Princeton Univ., NJ (United States); Qianchuan Zhao [Center for Intelligent and Networked Systems, Department of Automation, Tsinghua National Laboratory for Information Science and Technology, Tsinghua University, Beijing (China)

    2013-04-15

    Increasingly strict energy policies, rising energy prices, and a desire for a positive corporate image currently serve as incentives for multinational corporations to reduce their plants’ energy consumption. This paper quantitatively investigates and discusses the value of a traditional north-light roof using a complete building energy simulation and optimization framework. The findings indicate that the north-light system yields positive building energy performance for several climate zones, including: (i) Humid Subtropical; (ii) Semiarid Continental; (iii) Mediterranean; and (iv) Subtropical Highland. In the Subtropical Highland climate zone, for example, the building energy consumption of a north-light roof is up to 54% less than that of a conventional flat roof. Based on these positive findings, this paper further presents an optimization framework that alters the north-light roof shape to further improve its energy performance. To quantitatively guarantee a high probability of finding satisfactory designs while reducing the computational processing time, ordinal optimization is introduced into the scheme. The Subtropical Highland case study shows further energy building consumption reduction of 26% for an optimized north-light roof shape. The presented evaluation and optimization framework could be used in designing a plant with integrated north-lights roof that aim at energy efficiency while maintaining environmental occupant comfort levels.

  18. Identification of historical lead sources in roof dust and recent lake sediments from an industrialized are: Indications from lead isotopes

    International Nuclear Information System (INIS)

    Chenhall, B.E.; Depers, A.M.; Jones, B.G.; Chiaradia, M.

    1997-01-01

    X-ray fluorescence and stable lead (Pb) isotopic analyses have been undertaken on dusts, known from microscopic investigation to contain significant quantities of industrially- and urban-derived particulate matter, present in the roof cavities of houses in the Illawarra region (N.S.W., Australia), with the objective of examining the historic record of Pb pollution. All investigated houses contained in excess of 250 μg g -1 Pb, with dwellings close to a copper smelter, in a large industrial complex including a major steelworks, containing higher (>2500 μg g -1 ) Pb concentrations. The isotopic composition in the dusts, expressed here as 206 Pb/ 204 Pb, is relatively constant at 17.0, irrespective of dwelling age or distance from the industrial complex. Contamination of the dusts by Pb sourced from paint cannot explain the isotopic uniformity of the dust samples. Isotopic modelling indicates that the dusts contain Pb derived from the copper smelter, gasoline-air Pb and a minor contribution from the steelworks. Isotopic calculations, together with records of particulate pollution emission, indicate a link between the Pb in roof dusts and Pb contamination of the near surface lagoonal sediments. Over the last five decades, atmospheric fallout of Pb-bearing particulate matter appears to have been the dominant pathway for addition of Pb to the lagoon and dwellings in the Illawarra region

  19. Testing of coatings for the nuclear industry

    International Nuclear Information System (INIS)

    Goldberg, G.

    1977-01-01

    Commercial scale nuclear power generating plant coatings must be able to withstand simultaneous exposure both to high humidity, and to cumulative radiation dosage, at elevated temperatures, for the design life of the plant. The coatings must be decontaminable by means other than by stripping, that is, actual physical removal, and must be of sufficient durability to withstand projected conditions of a loss of coolant accident. Tests to show that coatings are expected to do more than retard corrosion and erosion are described

  20. Glass and glass–ceramic coatings, versatile materials for industrial ...

    Indian Academy of Sciences (India)

    Unknown

    such as abrasion, impact etc as compared to other coating materials applied by thermal spraying in its different forms viz. ... in some systematic way information on glass and glass– ... the industries by proper maintenance of the machinery/.

  1. Green roofs

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2010-04-01

    Full Text Available , beetles and spiders); and the number of birds that nest in vegetated roofs (including kestrels, swallows, and wagtails). Objective The primary objective of a green roof is to create a living habitat in an otherwise barren environment, hence the use... the negative environmental impacts including plant and insect specie loss. Thus at a philosophical level green roofs support the notion “replace what you displace”. Key ecological issues that can be addressed through green roofs include: Negative effects...

  2. Low VOC Barrier Coating for Industrial Maintenance

    Science.gov (United States)

    2007-11-01

    Property Documented No less than 7 mils Property Documented Properties Documented Property Documented Property Documented LVBC Fingerprint ... canvas or other approved shoe covers when walking on coated surfaces, regardless of curing time allowed. For heavily trafficked areas, provide

  3. Green roofs : a watertight perspective

    Energy Technology Data Exchange (ETDEWEB)

    Honza, D. [Honza Group Inc., Columbia, MD (United States)]|[Barrett Co., Millington, NJ (United States)

    2005-07-01

    While there is a growing acceptance of the ecological benefits of green roofs, many roofing contractors view green roofs with suspicion. The roofing industry is a high-volume, low-margin cost-driven industry which promotes a minimum standard commodity mentality. Roofing and waterproofing is the largest source of claims against architects and engineers. This paper suggested that architectural firms and engineering firms can reduce many issues associated with roofing problems by investigating and understanding materials, demands of projects, and preparing thorough specifications. Long-term exposure to the sun's rays will impact the chemical make-up of the roofing material, and water can break down the surface molecular structure of the membrane. Daily, yearly and event-related temperature variations can subject membranes to thermal induced stresses. Many roofs leak as a result of abuse during construction. Understanding and anticipating the performance problems of membranes can give green roof designers the ability to address limitations through good design. The membrane for a green roof should have superior abuse resistance; elastic properties, and resistance to long-term wet or saturated environments. Flashings for green roofs must exceed minimum standards. Membranes should be tested for watertightness before components are installed using electronic field vector mapping. Overburden should be installed after the membrane installation is proven to be watertight. It was concluded that higher design standards are required for green roofs, as many traditional roof membranes fail prematurely. A review of widely used membranes in the roofing and waterproofing industry included modified bitumen; built-up roofing; cured synthetic rubber sheets; thermalplastic membranes; self-adhering modified bitumen; and rubberized asphalt. 6 refs., 2 tabs., 6 figs.

  4. The properties degradation of exposed GFRP roof

    Science.gov (United States)

    Zainudin, Mohammad; Diharjo, Kuncoro; Kaavessina, Mujtahid; Setyanto, Djoko

    2018-02-01

    There is much consideration of roof selection as a protector of a building against the outside weather, such as lightweight, strong stiff, corrosion resistant and guarantee for the availability of products. Based on these considerations, glass fiber reinforced polymer (GFRP) roof is a roof which can fulfill the requirement. The objective of this research is to investigate the degradation of physical and mechanical properties of GFRP roof exposed in outside weather. This GFRP roof composite was produced using a sheet molding compound (SMC) supplied by PT Intec Persada, Tangerang, Indonesia. There are two kinds GFRP roofs evaluated in this research that are GFRP roof exposed within 7 years and new GFRP roof that has not been exposed. The GFRP roofs were cut manually for preparing the specimens for hardness test, tensile test, SEM and FTIR test. The results show that the GFRP roof exposed within 7 years had the degradation of properties compared to the new GFRP roof. The exposed GFRP roof had lower strength and hardness compared to the new GFRP roof. The SEM observation indicates that exposed GFRP roof had the debonding of fiber on the surface, and in contrast, there are no debonding of fiber in the new GFRP roof surface. It can be recommended that the exposed GFRP roof may be repaired to enhance its performance and can re-increase its properties using the coating.

  5. Study of radioactivity diffusion for bitumen-coated blocks produced by an industrial coating plant

    International Nuclear Information System (INIS)

    Rodier, J.; Lefillatre, G.

    1969-01-01

    The solidification by bitumen of chemical coprecipitation sludges from the Marcoule waste treatment station has been studied in the laboratory and has led to the construction of an industrial coating plant. The quality of the coated material obtained has been controlled by the lixiviation test carried out with ordinary water and with sea-water on 45 ml laboratory samples and on industrial coated blocks of 150 litres. Tests on blocks of such a size have necessitated the installation of three special tanks. Two, each of 2000 litres capacity, contain ordinary and sea-water which was continuously recycled at a rate of 2.5 cm/hr and renewed periodically. In the third tank having a capacity of 11000 litres, the coated block was buried in earth and sprinkled with ordinary water with a view to studying the migration of radioelements in soil. The results of these tests confirm those obtained during the laboratory experiments. (authors) [fr

  6. Prolong Your Roof's Performance: Roof Asset Management.

    Science.gov (United States)

    Teitsma, Jerry

    2001-01-01

    Discusses the roof asset management process for maintaining a roof system's integrity and value in a cost-effective manner. Included is a breakdown of roofing surface characteristics for multiply and single ply roofing systems. (GR)

  7. Energy efficiency opportunities within the powder coating industry

    Energy Technology Data Exchange (ETDEWEB)

    Osbeck, Sofie; Bergek, Charlotte; Klaessbo, Anders (Swerea IVF AB, Moelndal (Sweden)), e-mail: anders.klassbo@swerea.se; Thollander, Patrik; Rohdin, Patrik (Dept. of Management and Engineering, Linkoeping Univeristy, Linkoeping (Sweden)); Harvey, Simon (Dept. of Energy and Environment, Chalmers Univ. of Technology, Goeteborg (Sweden))

    2011-06-15

    A new challenge to reduce energy usage has emerged in Swedish industry because of increasing energy costs. Energy usage in the Swedish powder coating industry is about 525 GWh annually. This industry has a long and successful record of working towards reduced environmental impact. However, they have not given priority to energy saving investments. Electricity and LPG, for which end-user prices are predicted to increase by as much as 50 - 60% by 2020, are the main energy carriers used in the plants. This paper presents the results of two detailed industrial energy audits conducted with the aim of quantifying the energy efficiency potential for the Swedish powder coating industry. Energy auditing and pinch analysis methods were used to identify possible energy housekeeping measures and heat exchanging opportunities. The biggest users of energy within the plants are the cure oven, drying oven and pre-treatment units. The energy use reduction by the housekeeping measures is 8 - 19% and by thermal heat recovery an additional 8 - 13%. These measures result in an average energy cost saving of 25% and reduction of carbon dioxide emissions of 30%. The results indicate that the powder coating industry has a total energy efficiency potential of at least 20%

  8. Corrosion protection by organic coatings in gas and oil industry

    International Nuclear Information System (INIS)

    Hussain, A.

    2008-01-01

    The drive to improve performance of coatings as protection against corrosion for automotive, aerospace and oil and gas industries is a never-ending story. Surface preparation is the most important single factor when a substrate surface e.g. steel is to be protected with a coating. This implies an extremely accurate and reliable characterisation of the substrate-surface prior to coating process and the investigation of polymeric coating materials. In order to have a durable adhesive bonding between the polymeric coating materials and the substrate i.e. to ensure prolonged life time and fewer maintenance intervals of coated products, a pre-treatment of the substrate is required in many cases. Sand blasting, corona /plasma pre.treatment of the substrate and the use of coupling agents like organo silanes are well accepted recent methods. Advanced surface analytical techniques like ESCA and TOFSIMS are proving to be extremely helpful in the chemical characterisation of the substrate surface. Contamination e.g. fat residues, tensides etc. on the substrate is one of the most serious enemies of adhesive bonding and the above mentioned techniques are playing a vital role in combating the enemy. Modern thermal analytical methods have made tremendous contribution to the development and quality control of high-performance polymeric coatings. MDSC, DMA and DETA are proving to be very useful tools for the characterisation of high-performance coating materials. An in-depth understanding of the structure-property relationship of these materials, predominantly epoxy and polyurethane coating systems, is a pre-requisite for their successful application and subsequent Quality Control. (author)

  9. Leaf Roof – designing luminescent solar concentrating PV roof tiles

    NARCIS (Netherlands)

    Reinders, A.H.M.E.; Doudart de la Grée, G.C.H.; Papadopoulos, A.; Rosemann, A.L.P.; Debije, M.G.; Cox, M.G.D.M.; Krumer, Z.

    2016-01-01

    The Leaf Roof project on the design features of PV roof tiles using Luminescent Solar Concentrator (LSC) technology has resulted in a functional prototype . The results are presented in the context of industrial product design with a focus on the aesthetic aspects of LSCs. This paper outlines the

  10. Leaf Roof - Designing Luminescent Solar Concentrating PV Roof Tiles

    NARCIS (Netherlands)

    Reinders, Angelina H.M.E.; Doudart de la Gree, G.; Papadopoulos, A..; Rosemann, A.; Debije, M.G.; Cox, M.; Krumer, Zachar

    2016-01-01

    The Leaf Roof project on the design features of PV roof tiles using Luminescent Solar Concentrator (LSC) technology [1] has resulted in a functional prototype. The results are presented in the context of industrial product design with a focus on the aesthetic aspects of LSCs [2]. This paper outlines

  11. The technical viability of alternative blowing agents in polyisocyanurate roof insulation: A cooperative industry/government project

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.; Courville, G.E.; Desjarlais, A.O.; Graves, R.S.; Linkous, R.L.; McElroy, D.L.; Weaver, F.J.; Wendt, R.L.; Yarbrough, D.W.

    1993-06-01

    This report is a summary of the cooperative industry/government program to establish the viability of alternative blowing agents to chlorofluorocarbons (CFCs). The project was initiated in 1989 following two workshops that focused on needed research on thermal insulation blown with substitutes for CFC-11 and CFC-12. The project is directed by a steering committee of representatives of the sponsors and of Oak Ridge National Laboratory (ORNL). The purpose of the project is to determine if the performance of polyisocyanurate (PIR) roof insulation foam boards blown with alternate agents differs from the performance of boards blown with CFC-1. This report describes apparent thermal conductivity (k) results obtained from field and laboratory tests from 1989 to 1992 on a set of experimental PIR laminate boardstock produced to evaluate the viability of alternative hydrochlorofluorocarbons (HCFCs) as blowing agents. All boardstock was manufactured from similar formulations that were not optimized for thermal performance. Commercial broadstock made in the future may differ in performance from this set. The PIR boards were prepared with CFC-11, HCFC-123, HCFC-141b, and 50/50 and 65/35 blends of HCFC-123/HCFC-141b.

  12. Demonstration of energy savings of cool roofs

    Energy Technology Data Exchange (ETDEWEB)

    Konopacki, S.; Gartland, L.; Akbari, H. [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technologies Div.; Rainer, L. [Davis Energy Group, Davis, CA (United States)

    1998-06-01

    Dark roofs raise the summertime air-conditioning demand of buildings. For highly-absorptive roofs, the difference between the surface and ambient air temperatures can be as high as 90 F, while for highly-reflective roofs with similar insulative properties, the difference is only about 20 F. For this reason, cool roofs are effective in reducing cooling energy use. Several experiments on individual residential buildings in California and Florida show that coating roofs white reduces summertime average daily air-conditioning electricity use from 2--63%. This demonstration project was carried out to address some of the practical issues regarding the implementation of reflective roofs in a few commercial buildings. The authors monitored air-conditioning electricity use, roof surface temperature, plenum, indoor, and outdoor air temperatures, and other environmental variables in three buildings in California: two medical office buildings in Gilroy and Davis and a retail store in San Jose. Coating the roofs of these buildings with a reflective coating increased the roof albedo from an average of 0.20--0.60. The roof surface temperature on hot sunny summer afternoons fell from 175 F--120 F after the coating was applied. Summertime average daily air-conditioning electricity use was reduced by 18% (6.3 kWh/1000ft{sup 2}) in the Davis building, 13% (3.6 kWh/1000ft{sup 2}) in the Gilroy building, and 2% (0.4 kWh/1000ft{sup 2}) in the San Jose store. In each building, a kiosk was installed to display information from the project in order to educate and inform the general public about the environmental and energy-saving benefits of cool roofs. They were designed to explain cool-roof coating theory and to display real-time measurements of weather conditions, roof surface temperature, and air-conditioning electricity use. 55 figs., 15 tabs.

  13. Application of Industrial XRF Coating Thickness Analyzer for Phosphate Coating Thickness on Steel

    Directory of Open Access Journals (Sweden)

    Aleksandr Sokolov

    2018-03-01

    Full Text Available The results of industrial application of an online X-ray fluorescence coating thickness analyzer for measuring the thickness of phosphate coatings on moving steel strips are considered in the article. The target range of coating thickness to be measured is from tens to hundreds of mg/m2 in a measurement time of 10 s. The measurement accuracy observed during long-duration factory acceptance test was 10–15%. The coating thickness analyzer consists of two XRF gauges, mounted above and below the steel strip and capable of moving across the moving strip system for their suspension and relocation and electronic control unit. Fully automated software was developed to automatically and continuously (24/7 control both gauges, scanning both sides of the steel strip, and develop and test methods for measuring new coatings. It allows performing offline storage and retrieval of the measurement results, remotely controlling the analyzer components and measurement modes from a control room. The developed XRF coating thickness analyzer can also be used for real-time measurement of other types of coatings, both metallic and non-metallic.

  14. Roof assembly

    CSIR Research Space (South Africa)

    De Villiers, A

    2010-01-01

    Full Text Available The objective of this chapter is to provide sustainability criteria for roof system design that can be used by planners, designers and developers as a planning, design and development guide for sustainable building projects....

  15. Green Roofs

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-08-01

    A New Technology Demonstration Publication Green roofs can improve the energy performance of federal buildings, help manage stormwater, reduce airborne emissions, and mitigate the effects of urban heat islands.

  16. The coating of surfaces for use in the nuclear industry

    International Nuclear Information System (INIS)

    1984-01-01

    This Code of Practice provides general advice to designers and others on the factors affecting the choice of coating for use within the nuclear industry. It itemises those design features, which are pertinent to facilitating decontamination and specifies the optimum generic types of coating for a variety of working conditions. Data sheets on commercially available products are included in Section 6 of the Code under the appropriate generic type. Information provided on the data sheets includes a measure of the ease of decontamination of the coating using the accepted method of testing (currently as specified in BS 4247 Part 1) and other nuclear information, where available, i.e. radiation resistance, exhalation rate for radionuclide gases radon and thoron. It also indicates the more important conventional properties of the product. (author)

  17. Producing superhydrophobic roof tiles

    International Nuclear Information System (INIS)

    Carrascosa, Luis A M; Facio, Dario S; Mosquera, Maria J

    2016-01-01

    Superhydrophobic materials can find promising applications in the field of building. However, their application has been very limited because the synthesis routes involve tedious processes, preventing large-scale application. A second drawback is related to their short-term life under outdoor conditions. A simple and low-cost synthesis route for producing superhydrophobic surfaces on building materials is developed and their effectiveness and their durability on clay roof tiles are evaluated. Specifically, an organic–inorganic hybrid gel containing silica nanoparticles is produced. The nanoparticles create a densely packed coating on the roof tile surface in which air is trapped. This roughness produces a Cassie–Baxter regime, promoting superhydrophobicity. A surfactant, n-octylamine, was also added to the starting sol to catalyze the sol–gel process and to coarsen the pore structure of the gel network, preventing cracking. The application of ultrasound obviates the need to use volatile organic compounds in the synthesis, thereby making a ‘green’ product. It was also demonstrated that a co-condensation process effective between the organic and inorganic species is crucial to obtain durable and effective coatings. After an aging test, high hydrophobicity was maintained and water absorption was completely prevented for the roof tile samples under study. However, a transition from a Cassie–Baxter to a Wenzel state regime was observed as a consequence of the increase in the distance between the roughness pitches produced by the aging of the coating. (paper)

  18. Laser deposition of coatings for aeronautical and industrials turbine blades

    Energy Technology Data Exchange (ETDEWEB)

    Teleginski, V. [Instituto Federal de Sao Paulo (IFSP), SP (Brazil); Silva, S.A.; Riva, R.; Vasconcelos, G. [Instituto de Estudos Avancados (IEAv), Sao Jose dos Campos, SP (Brazil); Silva Pita, G.R. [Universidade Braz Cubas, Mogi das Cruzes, SP (Brazil); Yamin, L.S. [Escola Tecnica Everardo Passos (ETEP), Sao Jose dos Campos, DP (Brazil)

    2016-07-01

    Full text: Zirconium-based ceramic materials are widely employed as Thermal Barrier Coatings (TBC), due to its excellent wear and corrosion resistance at high temperatures. The application of TBC includes aeronautical and industrials turbine blades. The working conditions include oxidizing environments and temperatures above 1000°C. The zirconium-based ceramics are developed in such a way that the microstructural control is possible through the control of chemical composition, fabrication route and, thermal treatment. The present paper proposes a laser route to deposit the TBC coating, where the microstructural control is a function of power density and interaction time between the laser beam and the material. The main objective of this work is to study the influence of the CO2 laser beam (Synrad Evolution 125) parameters: power density and interaction time, on the deposition process of yttria-stabilized zirconia (YSZ) powders on NiCrAlY/AISI 316L substrates. The resulting coating surface and interface were characterized by scanning electron microscopy, energy dispersive spectroscopy and X-ray diffraction. The results indicate that is possible to match laser parameters of scanning speed and intensity to produce homogenous coatings. The X-Ray analyses show that the obtained ceramic coating has reduced number of phases, with prevalence of tetragonal phase.(author)

  19. Thin coatings for heavy industry: Advanced coatings for pipes and valves

    Science.gov (United States)

    Vernhes, Luc

    Pipes and valves are pressure vessels that regulate the flow of materials (liquids, gases, and slurries) by controlling the passageways. To optimize processes, reduce costs, and comply with government regulations, original equipment manufacturers (OEMs) must maintain their products in state-of-the-art condition. The first valves were invented over 3,000 years ago to supply water to farms and cities. They were made with bronze alloys, providing good corrosion resistance and acceptable tribological performance. The industrial revolution drove manufacturers to develop new and improved tribological materials. In the 20th century, innovative alloys such as Monel copper-nickel and Stellite cobalt-chrome as well as hard chrome plating were introduced to better control tribological properties and maximize in-service life. Since then, new materials have been regularly introduced to extend the range of applications for valves. For example, Teflon fluoropolymers are used in corrosive chemical and petrochemical processes, the nickel-based superalloys Hastelloy and Inconel for petrochemical applications, and creep-resistant chromium-rich F91 steel for supercritical power plants. Recently, the valve industry has embraced the use of hard thermal sprayed coatings for the most demanding applications, and is investing heavily in research to develop the most suitable coatings for specific uses. There is increasing evidence that the optimal solution to erosive, corrosive, and fretting wear problems lies in the design and manufacture of multi-layer, graded, and/or nanostructured coatings and coating systems that combine controlled hardness with high elastic modulus, high toughness, and good adhesion. The overall objectives of this thesis were 1) to report on advances in the development of structurally controlled hard protective coatings with tailored mechanical, elastoplastic, and thermal properties; and 2) to describe enhanced wear-, erosion-, and corrosion-resistance and other

  20. PV ready roofing systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The integration of PV technology into roofs of houses has become very popular in the United States, Japan, Germany and The Netherlands. There could be a considerable market in the UK for these systems, given the large number of houses that are projected to be built in the next 10 years, and taking account of increased awareness of energy issues. A significant proportion of the market share of annual installed PV is for solar PV systems installed into homes (currently 15%), this is expected to rise to 23% (900MW) by 2010. The grid connected roof and building mounted facade systems represent the fastest growing market for PV systems in Europe. In conclusion, therefore, innovative approached for fixing PV technology onto roofs have been identified for both domestic roofs and for the commercial sector. With reference to production methodologies within the roofing industry, both approaches should be capable of being designed with PV-ready connections suitable for fixing PV modules at a later date. This will help overcome the key barriers of cost of installation, skills required and the lack of retrofit potential. Based on the results of this project, Sustainable Energy together with PV Systems are keen to take forward the full research and development of PV-ready systems for both the domestic and commercial sectors.

  1. Summer and Winter Effect of Innovative Cool Roof Tiles on the Dynamic Thermal Behavior of Buildings

    Directory of Open Access Journals (Sweden)

    Anna Laura Pisello

    2014-04-01

    Full Text Available Cool roofs represent an acknowledged passive cooling technique to reduce building energy consumption for cooling and to mitigate urban heat island effects. This paper concerns the evaluation of the dynamic effect of new cool roof clay tiles on building thermal performance in summer and winter conditions. To this end, these properties have been analyzed on traditional roof brick tiles through an indoor and outdoor two-year long continuous monitoring campaign set up in a residential building located in central Italy. The analysis and the cooperation with industrial companies producing brick tiles and reflective coatings allowed the production of a new tile with notable “cool roof” properties through the traditional industrial manufacturing path of such tiles. Notable results show that during summer the high reflection tiles are able to decrease the average external roof surface temperature by more than 10 °C and the indoor operative temperature by more than 3 °C. During winter the average external surface temperature is lower with high reflection tiles by about 1 °C. Singular optic-thermal phenomena are registered while evaluating the dynamics of the cool roof effect. Interesting findings show how the sloped cool roof application could suggest further considerations about the dynamic effect of cool roofs.

  2. Proposal for the award of an industrial support contract for minor metalwork, metal fittings, cladding and roofing at CERN

    CERN Document Server

    2006-01-01

    This document concerns the award of a contract for minor metalwork, metal fittings, cladding and roofing at CERN. The Finance Committee is invited to agree to the negotiation of a contract with the firm INIZIATIVE INDUSTRIALI SRL (IT), the lowest bidder, for the provision of minor metalwork, metal fittings, cladding and roofing at CERN for three years for a total amount not exceeding 1 467 895 euros (2 258 301 Swiss francs), not subject to revision for two years. The contract will include options for two one-year extensions beyond the initial three-year period.

  3. Evaluation of Roof Bolting Requirements Based on In-Mine Roof Bolter Drilling

    Energy Technology Data Exchange (ETDEWEB)

    Syd S. Peng

    2005-10-01

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on this information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. For the prediction of roof geology and stability condition in real time, a micro processor was used and a program developed to monitor and record the drilling parameters of roof bolter. These parameters include feed pressure, feed flow (penetration rate), rotation pressure, rotation rate, vacuum pressure, oil temperature of hydraulic circuit, and signals for controlling machine. From the results of a series of laboratory and underground tests so far, feed pressure is found to be a good indicator for identifying the voids/fractures and estimating the roof rock strength. The method for determining quantitatively the location and the size of void/fracture and estimating the roof rock strength from the drilling parameters of roof bolter was developed. Also, a set of computational rules has been developed for in-mine roof using measured roof drilling parameters and implemented in MRGIS (Mine Roof Geology Information System), a software package developed to allow mine engineers to make use of the large amount of roof drilling parameters for predicting roof geology properties automatically. For the development of roof bolting criteria, finite element models were developed for tensioned and fully grouted bolting

  4. Releasability of asbestos fibers from weathered roof cement.

    Science.gov (United States)

    Oberta, Andrew F; Poye, Lee; Compton, Steven P

    2018-03-26

    Chrysotile asbestos fibers were added to roofing products, including roof cement, for several decades. The fibers were described as "encapsulated" and therefore incapable of being released, an assertion that is disproved by the study reported herein. Three test panels of roof cement from the original container were exposed to ambient weathering in 2015 and 2016. Two panels were then sampled using the ASTM D5755 microvacuum method. Sampling revealed a light brown sub-layer under the dark brown surface layer, both of which crumbled and became friable during sampling. Analysis of the microvacuum samples with transmission electron microscopy showed that the material on the two panels contained 4,432,000 and 3,320,000 asbestos structures per cm² with nearly all of the structures consisting of fibers less than 5 µm long. Energy dispersive spectrometry determined that none of the fibers reported were coated with asphalt. The presence of free fibers were confirmed by direct examination of the surfaces of the panels and of dust released from handling the panels via scanning electron microscopy. This study confirmed the releasability of uncoated asbestos fibers from dried roof cement that was indicated in two previous studies published in 2007 and 2010. These results suggest that the finding of the 5th Circuit Court in 1997 that uncoated airborne asbestos fibers cannot be released from roof cement, and therefore do not present a potential exposure by inhalation, was erroneous in retrospect. Theexemption of roof cement from regulation under the Occupational Safety and Health Administration Construction Industry Standard for asbestos by the Court should not be relied on by employers of workers who remove weathered asbestos-containing roof cement, and precautions should be taken against exposure to airborne asbestos fibers during this work.

  5. Development of sustainable paper coatings using nanoscale industrial surface processing

    DEFF Research Database (Denmark)

    Markert, Frank; Breedveld, Leo; Lahti, Johanna

    in the PlasmaNice project, as environmental and social aspects are addressed using methods like life cycle check (LCC), life cycle assessment (LCA), and industrial risk assessment (RA) within the boundary of an economical production for different market segments. The results are intended to be used partly...... products, and the process and material developers providing new coatings with specific properties. The combination of RA and LCA/LCC within the early stages of product development provide a more holistic approach, It is commonly believed to be also economical beneficial as changes are easier to implement...

  6. Effect of diffuse roof cover with anti-reflection coating for roses; Effect van diffuus kasdek met Anti Reflectie coating bij Roos

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Victoria, N.; Kempkes, F.

    2012-10-15

    The rose Red Naomi was cultivated in two greenhouses at Wageningen UR Greenhouse Horticulture in Bleiswijk, Netherlands (August 2010 - September 2011). One greenhouse covered with normal float glass; the other with AR coated diffuse glass (70% haze). This Anti-Reflection coating on both glass sides compensated for the loss in light transmission caused by the diffusing structure in the glass. The diffuse AR glass lead to a 5.2% higher production (>6.1% fresh weight). Sunscreens were necessary in spring and summer to avoid high light levels on the flower buds, as they cause very high bud temperatures leading to quality problems (blue petal edges and burnt leaf tips). The diffuse greenhouse cover allowed a 100 W/m{sup 2} higher screening threshold than the reference glass. This caused a 2.7% higher daily light integral, able to explain part of the extra production obtained. Part of the extra production achieved can not be explained by the measured factors as no differences were found in the amount of light intercepted by the crop or in leaf photosynthesis under both cover types. The light under the diffuse AR cover was nevertheless much smoother, so the crop seemed to suffer less (lower bud temperatures and less burned leaf tips), and this should provide an explanation for the rest of the extra production. The cover properties did not influence disease development (powdery mildew). The obtained extra production makes the tempered, diffuse glass with Anti Reflection coating on both sides economically feasible [Dutch] Tussen augustus 2010 en september 2011 is bij Wageningen UR Glastuinbouw het effect van diffuus glas, met dubbelzijdige AR coating, op de productie en energiegebruik van roos 'Red Naomi' onderzocht. Onder het diffuse glas werden 5,2% meer bloemtakken geproduceerd, deze rozen waren ook iets langer en zwaarder (6,1% meer versgewicht). Dit verschil kan deels verklaard worden doordat er onder het diffuse glas pas bij hogere stralingsniveau

  7. Clean Air Act Guidelines and Standards for Solvent Use and Surface Coating Industry

    Science.gov (United States)

    This page contains the stationary sources of air pollution for the solvent use and surface coating industries, and their corresponding air pollution regulations. To learn more about the regulations for each industry, just click on the links below.

  8. Requirements for Weatherproofing Thin Shell Concrete Roofs. Proceedings of the Conference of Building Research Institute, Division of Engineering and Industrial Research (Spring 1961).

    Science.gov (United States)

    National Academy of Sciences - National Research Council, Washington, DC.

    Topics discussed include--(1) requirements for weatherproofing and sealant materials for thin shell concrete roof, (2) effect of physical factors on weatherproofing of thin shell concrete roofs, (3) problems and limitations imposed by thin shell concrete roofs and their effect on weatherproofing and sealant materials, and (4) properties and uses…

  9. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    Energy Technology Data Exchange (ETDEWEB)

    Syd S. Peng

    2003-07-15

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal, potash, salt etc. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on such information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The selected site and the field testing plan enabled us to test all three aspects of roof geological features. The development of the data interpretation methodologies and the geology mapping computer program have also been preceding well.

  10. Effect of pretreatments on electrodeposited epoxy coatings for electronic industries

    Directory of Open Access Journals (Sweden)

    Sironmani Palraj

    2016-02-01

    Full Text Available Waterborne epoxy coatings were prepared on aluminium (Al surfaces by cathodic electro-deposition on the pretreated surface of pickling, phosphating, chromating and anodizing. The electro-deposition experiments were done at two different voltages, 15 V and 25 V at room temperature in 10% epoxy coating formulations. Corrosion and thermal behavior of these coatings were investigated using electrochemical impedance spectroscopy (EIS and thermo gravimetric analysis (TGA. The coating exhibits better corrosion resistance in anodized Al surface than the other. But, TGA studies show that the thermal stability is higher in anodized and chromated Al surfaces. The surface morphology of these coatings were analyzed by SEM and AFM studies.

  11. Integral design of active energy roofs

    NARCIS (Netherlands)

    Quanjel, E.M.C.J.

    2006-01-01

    A wide variety of new products, such as photovoltaic (PV) systems and solar collectors, roof lights, ventilation devices, insulation and safety devices, is finding its way into the roofing industry. As a result many problems occurred, resulting in poor quality, unsafe working conditions and high

  12. Substituição de areia de quartzo por finos de gnaisse em massa cerâmica para telhas: teste industrial Replacing quartz sand for gnaisse fines waste into roofing tile body: industrial test

    Directory of Open Access Journals (Sweden)

    C. M. F. Vieira

    2008-12-01

    Full Text Available Foi avaliado o efeito da substituição de areia por um resíduo de beneficiamento de rocha ornamental, finos de gnaisse, em uma massa de cerâmica vermelha utilizada para fabricação de telhas. Foram preparadas telhas prensadas, do tipo "portuguesa", para queima a 900 ºC em forno industrial. As seguintes propriedades foram determinadas: retração linear, absorção de água e carga de ruptura na flexão. Além disso, avaliaram-se as características das matérias-primas e a plasticidade das composições por meio dos limites de Atterberg. Os resultados indicaram que a utilização de finos de gnaisse em substituição à areia possibilitou uma melhoria na trabalhabilidade/plasticidade da massa cerâmica e acarretou uma pequena redução na absorção de água das telhas. A resistência mecânica não se alterou, dentro da precisão estatística das medidas.The effect of replacing sand for gnaisse sawing waste into a red ceramic body used for roofing tile fabrication was evaluated. Pressed roofing tiles, "portuguese" style, were prepared before firing at 900 ºC in an industrial furnace. The following properties were evaluated: linear shrinkage, water absorption and load rupture strength. The plasticity of the elaborated compositions was determined by the Atterberg limits. The results show that the use of gnaisse fines replacing the sand, improved the workability of the ceramic body and promoted a slight decrease on the water absorption of the roofing tiles. The mechanical strength was not changed within the statistical error.

  13. Next Generation Thermal Barrier Coatings for the Gas Turbine Industry

    Science.gov (United States)

    Curry, Nicholas; Markocsan, Nicolaie; Li, Xin-Hai; Tricoire, Aurélien; Dorfman, Mitch

    2011-01-01

    The aim of this study is to develop the next generation of production ready air plasma sprayed thermal barrier coating with a low conductivity and long lifetime. A number of coating architectures were produced using commercially available plasma spray guns. Modifications were made to powder chemistry, including high purity powders, dysprosia stabilized zirconia powders, and powders containing porosity formers. Agglomerated & sintered and homogenized oven spheroidized powder morphologies were used to attain beneficial microstructures. Dual layer coatings were produced using the two powders. Laser flash technique was used to evaluate the thermal conductivity of the coating systems from room temperature to 1200 °C. Tests were performed on as-sprayed samples and samples were heat treated for 100 h at 1150 °C. Thermal conductivity results were correlated to the coating microstructure using image analysis of porosity and cracks. The results show the influence of beneficial porosity on reducing the thermal conductivity of the produced coatings.

  14. Development of Ceramic Coating on Metal Substrate using Industrial Waste and Ore Minerals

    Science.gov (United States)

    Bhuyan, S. K.; Thiyagarajan, T. K.; Mishra, S. C.

    2017-02-01

    The technological advancement in modern era has a boon for enlightening human life; but also is a bane to produce a huge amount of (industrial) wastes, which is of great concern for utilization and not to create environmental threats viz. polution etc. In the present piece of research work, attempts have been made to utilize fly ash (wastes of thermal power plants) and along with alumina bearing ore i.e. bauxite, for developing plasma spray ceramic coatings on metals. Fly ash and with 10 and 20% bauxite addition is used to deposit plasma spray coatings on a metal substrate. The surface morphology of the coatings deposited at different power levels of plasma spraying investigated through SEM and EDS analysis. The coating thickness is measured. The porosity levels of the coatings are evaluated. The coating hardness isalso measured. This piece of research work will be beneficial for future development and use of industrial waste and ore minerals for high-valued applications.

  15. Life assessment of PVD based hard coatings by linear sweep voltammetry for high performance industrial application

    International Nuclear Information System (INIS)

    Malik, M.; Alam, S.; Irfan, M.; Hassan, Z.

    2006-01-01

    PVD based hard coatings have remarkable achievements in order to improve Tribological and surface properties of coating tools and dies. As PVD based hard coatings have a wide range of industrial applications especially in aerospace and automobile parts where they met different chemical attacks and in order to improve industrial performance these coatings must provide an excellent resistance against corrosion, high temperature oxidation and chemical reaction. This paper focuses on study of behaviour of PVD based hard coatings under different corrosive environments like as H/sub 2/SO/sub 4/, HCl, NaCl, KCl, NaOH etc. Corrosion rate was calculate under linear sweep voltammetry method where the Tafel extrapolation curves used for continuously monitoring the corrosion rate. The results show that these coatings have an excellent resistance against chemical attack. (author)

  16. Acid-resistant organic coatings for the chemical industry: a review

    DEFF Research Database (Denmark)

    Møller, Victor Buhl; Dam-Johansen, Kim; Frankær, Sarah Maria Grundahl

    2017-01-01

    Industries that work with acidic chemicals in their processes need to make choices on how to properly contain the substances and avoid rapid corrosion of equipment. Certain organic coatings and linings can be used in such environments, either to protect vulnerable construction materials, or......, in combination with fiber reinforcement, to replace them. However, degradation mechanisms of organic coatings in acid service are not thoroughly understood and relevant quantitative investigations are scarce. This review describes the uses and limitations of acid-resistant coatings in the chemical industry...

  17. Wear of different PVD coatings at industrial fine-blanking field tests

    Directory of Open Access Journals (Sweden)

    Liina Lind

    2015-09-01

    Full Text Available Thin hard physical vapor deposited (PVD coatings play significant role on wear performance of fine-blanking punches in the presence of extremely high contact stresses. Nevertheless it seems that in blanking or fine-blanking the coatings are selected based on coincidence, trial-error-method or latest trends. There is limited information about planning and conducting the fine-blanking industrial field tests and measuring the wear of different coatings. In the present study a set of fine-blanking punches and laboratory specimens were prepared with three coatings – TiCN, nACRo and nACo. As substrate material Böhler S390 Microclean high speed steel was used. Coating mechanical properties (modulus of elasticity and nanohardness were measured and wear rate with alumina ball was determined using the reciprocating sliding test. Wear of coatings was measured from punches after industrial use. All of the tested coatings showed high variance of wear. However coatings nACo and nACRo have better average wear resistance in fine-blanking compared with the well-known TiCN. Industrial field tests show correlation to the ratio elastic strain to failure H/E.DOI: http://dx.doi.org/10.5755/j01.ms.21.3.7249

  18. Characterization of industrially produced galvannealed coating using cross-sectional specimen in TEM

    International Nuclear Information System (INIS)

    Chakraborty, A.; Saha, R.; Ray, R.K.

    2009-01-01

    Galvannealed coated sheet steels are extensively used in the automotive industry due to their inherent advantages, as compared to other zinc based coating, such as excellent spot weldability, good corrosion resistance and better paintability. Despite the above advantages, galvannealed coating suffers from poor formability due to the presence of hard and brittle Fe-Zn intermetallic phases. The formability of the coating depends on the amount and orientation of different Fe-Zn intermetallic phases. The present study deals with the characterization of an industrially produced galvannealed coating using cross-sectional specimen in a Transmission Electron Microscope. From the selected area diffraction patterns obtained in Transmission Electron Microscope, the orientations of the delta phase were calculated.

  19. Photovoltaic roof construction

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, W.W.

    1980-02-26

    In a batten-seam roof construction employing at least one photovoltaic cell module, the electrical conduits employed with the at least one photovoltaic cell module are disposed primarily under the battens of the roof.

  20. Renovation of Roof Structure

    DEFF Research Database (Denmark)

    Kjærbye, Per Oluf H

    1997-01-01

    A 30 year old not-watertight roof based on wooden boards with roofing felt have been changed to a pitched structure with cementos plates. At the same time more thermal insulation has been placed.......A 30 year old not-watertight roof based on wooden boards with roofing felt have been changed to a pitched structure with cementos plates. At the same time more thermal insulation has been placed....

  1. Green roof Malta

    OpenAIRE

    Gatt, Antoine

    2015-01-01

    In Malta, buildings cover one third of the Island, leaving greenery in the dirt track. Green roofs are one way to bring plants back to urban areas with loads of benefits. Antoine Gatt, who manages the LifeMedGreenRoof project at the University of Malta, tells us more. http://www.um.edu.mt/think/green-roof-malta/

  2. EPA's Green Roof Research

    Science.gov (United States)

    This is a presentation on the basics of green roof technology. The presentation highlights some of the recent ORD research projects on green roofs and provices insight for the end user as to the benefits for green roof technology. It provides links to currently available EPA re...

  3. Surface Coating of Plastic Parts for Business Machines (Industrial Surface Coating): New Source Performance Standards (NSPS)

    Science.gov (United States)

    Learn more about the new source performance standards (NSPS) for surface coating of plastic parts for business machines by reading the rule summary and history and finding the code of federal regulations as well as related rules.

  4. Novel GIMS technique for deposition of colored Ti/TiO₂ coatings on industrial scale

    Directory of Open Access Journals (Sweden)

    Zdunek Krzysztof

    2016-03-01

    Full Text Available The aim of the present paper has been to verify the effectiveness and usefulness of a novel deposition process named GIMS (Gas Injection Magnetron Sputtering used for the flrst time for deposition of Ti/TiO₂ coatings on large area glass Substrates covered in the condition of industrial scale production. The Ti/TiO₂ coatings were deposited in an industrial System utilizing a set of linear magnetrons with the length of 2400 mm each for covering the 2000 × 3000 mm glasses. Taking into account the speciflc course of the GIMS (multipoint gas injection along the magnetron length and the scale of the industrial facility, the optical coating uniformity was the most important goal to check. The experiments on Ti/TiO₂ coatings deposited by the use of GIMS were conducted on Substrates in the form of glass plates located at the key points along the magnetrons and intentionally non-heated during any stage of the process. Measurements of the coatings properties showed that the thickness and optical uniformity of the 150 nm thick coatings deposited by GIMS in the industrial facility (the thickness differences on the large plates with 2000 mm width did not exceed 20 nm is fully acceptable form the point of view of expected applications e.g. for architectural glazing.

  5. Advanced Energy Efficient Roof System

    Energy Technology Data Exchange (ETDEWEB)

    Jane Davidson

    2008-09-30

    Energy consumption in buildings represents 40 percent of primary U.S. energy consumption, split almost equally between residential (22%) and commercial (18%) buildings.1 Space heating (31%) and cooling (12%) account for approximately 9 quadrillion Btu. Improvements in the building envelope can have a significant impact on reducing energy consumption. Thermal losses (or gains) from the roof make up 14 percent of the building component energy load. Infiltration through the building envelope, including the roof, accounts for an additional 28 percent of the heating loads and 16 percent of the cooling loads. These figures provide a strong incentive to develop and implement more energy efficient roof systems. The roof is perhaps the most challenging component of the building envelope to change for many reasons. The engineered roof truss, which has been around since 1956, is relatively low cost and is the industry standard. The roof has multiple functions. A typical wood frame home lasts a long time. Building codes vary across the country. Customer and trade acceptance of new building products and materials may impede market penetration. The energy savings of a new roof system must be balanced with other requirements such as first and life-cycle costs, durability, appearance, and ease of construction. Conventional residential roof construction utilizes closely spaced roof trusses supporting a layer of sheathing and roofing materials. Gypsum board is typically attached to the lower chord of the trusses forming the finished ceiling for the occupied space. Often in warmer climates, the HVAC system and ducts are placed in the unconditioned and otherwise unusable attic. High temperature differentials and leaky ducts result in thermal losses. Penetrations through the ceilings are notoriously difficult to seal and lead to moisture and air infiltration. These issues all contribute to greater energy use and have led builders to consider construction of a conditioned attic. The

  6. Reduction of organic solvent emission by industrial use of electron-beam curable coatings

    International Nuclear Information System (INIS)

    Haering, E.

    1982-01-01

    Most industrial finishing processes operate by the use of liquid organic coating materials drying by solvent evaporation and subsequent chemical crosslinking reactions, in many cases also releasing cleavage products. These organic emissions contribute to air pollution and therefore many countries have issued restrictions in order to protect the environment. Complementary to other modern methods for reducing this problem, radiation chemistry enables an approach by radical chain polymerization which can be induced by exposure to electron radiation. This procedure is known as electron-beam curing of coatings or the EBC process. It utilizes well-developed accelerator equipment with voltages of 150 to 400kV at a minimum energy consumption. There is no necessity to use irradiation facilities based on the decay of radioisotopes. Free radical polymerization requires unsaturated resins as pain binders and polymerizable liquid compounds (monomers) as reactive diluents. Their crosslinking yields a high molecular network, the coating, without any emission of organic solvents or cleavage products. Moreover, the radiochemical formation of the paint film occurs extremely rapidly. The technical application of EBC coatings began by coating automotive plastic parts; a little later the finishing of wood products gained more industrial use as a non-polluting and energy-saving coating technology. Application methods in coating plastic foils in combination with vacuum metallizing and the production of decorative laminating papers for furniture followed. In 1981 new EBC pilot lines were installed for curing top coats on PVC foil and also for the coating of prefinished steel wheels for automobiles. In comparison with conventional solvent-based methods the industrial EBC process results in a nearly complete reduction of organic solvent emission avoiding air pollution and saving valuable petrochemical raw materials. This paper reviews the development of EBC during the last decade. (author)

  7. IMPROVED ROOF STABILIZATION TECHNOLOGIES

    International Nuclear Information System (INIS)

    Ebadian, M.A.

    1999-01-01

    Many U.S. Department of Energy (DOE) remediation sites have performed roof repair and roof replacement to stabilize facilities prior to performing deactivation and decommissioning (D and D) activities. This project will review the decision criteria used by these DOE sites, along with the type of repair system used for each different roof type. Based on this information, along with that compiled from roofing experts, a decision-making tool will be generated to aid in selecting the proper roof repair systems. Where appropriate, innovative technologies will be reviewed and applied to the decision-making tool to determine their applicability. Based on the results, applied research and development will be conducted to develop a method to repair these existing roofing systems, while providing protection for the D and D worker in a cost-efficient manner

  8. IMPROVED ROOF STABILIZATION TECHNOLOGIES

    Energy Technology Data Exchange (ETDEWEB)

    M.A. Ebadian, Ph.D.

    1999-01-01

    Many U.S. Department of Energy (DOE) remediation sites have performed roof repair and roof replacement to stabilize facilities prior to performing deactivation and decommissioning (D&D) activities. This project will review the decision criteria used by these DOE sites, along with the type of repair system used for each different roof type. Based on this information, along with that compiled from roofing experts, a decision-making tool will be generated to aid in selecting the proper roof repair systems. Where appropriate, innovative technologies will be reviewed and applied to the decision-making tool to determine their applicability. Based on the results, applied research and development will be conducted to develop a method to repair these existing roofing systems, while providing protection for the D and D worker in a cost-efficient manner.

  9. Establishing Green Roof Infrastructure Through Environmental Policy Instruments

    Science.gov (United States)

    Carter, Timothy; Fowler, Laurie

    2008-07-01

    Traditional construction practices provide little opportunity for environmental remediation to occur in urban areas. As concerns for environmental improvement in urban areas become more prevalent, innovative practices which create ecosystem services and ecologically functional land cover in cities will be in higher demand. Green roofs are a prime example of one of these practices. The past decade has seen the North American green roof industry rapidly expand through international green roof conferences, demonstration sites, case studies, and scientific research. This study evaluates existing international and North American green roof policies at the federal, municipal, and community levels. Green roof policies fall into a number of general categories, including direct and indirect regulation, direct and indirect financial incentives, and funding of demonstration or research projects. Advantages and disadvantages of each category are discussed. Salient features and a list of prompting standards common to successfully implemented green roof strategies are then distilled from these existing policies. By combining these features with data collected from an experimental green roof site in Athens, Georgia, the planning and regulatory framework for widespread green roof infrastructure can be developed. The authors propose policy instruments be multi-faceted and spatially focused, and also propose the following recommendations: (1) Identification of green roof overlay zones with specifications for green roofs built in these zones. This spatial analysis is important for prioritizing areas of the jurisdiction where green roofs will most efficiently function; (2) Offer financial incentives in the form of density credits and stormwater utility fee credits to help overcome the barriers to entry of the new technology; (3) Construct demonstration projects and institutionalize a commitment greening roofs on publicly-owned buildings as an effective way of establishing an educated

  10. Establishing green roof infrastructure through environmental policy instruments.

    Science.gov (United States)

    Carter, Timothy; Fowler, Laurie

    2008-07-01

    Traditional construction practices provide little opportunity for environmental remediation to occur in urban areas. As concerns for environmental improvement in urban areas become more prevalent, innovative practices which create ecosystem services and ecologically functional land cover in cities will be in higher demand. Green roofs are a prime example of one of these practices. The past decade has seen the North American green roof industry rapidly expand through international green roof conferences, demonstration sites, case studies, and scientific research. This study evaluates existing international and North American green roof policies at the federal, municipal, and community levels. Green roof policies fall into a number of general categories, including direct and indirect regulation, direct and indirect financial incentives, and funding of demonstration or research projects. Advantages and disadvantages of each category are discussed. Salient features and a list of prompting standards common to successfully implemented green roof strategies are then distilled from these existing policies. By combining these features with data collected from an experimental green roof site in Athens, Georgia, the planning and regulatory framework for widespread green roof infrastructure can be developed. The authors propose policy instruments be multi-faceted and spatially focused, and also propose the following recommendations: (1) Identification of green roof overlay zones with specifications for green roofs built in these zones. This spatial analysis is important for prioritizing areas of the jurisdiction where green roofs will most efficiently function; (2) Offer financial incentives in the form of density credits and stormwater utility fee credits to help overcome the barriers to entry of the new technology; (3) Construct demonstration projects and institutionalize a commitment greening roofs on publicly-owned buildings as an effective way of establishing an educated

  11. ROOF GARDENS AS LANDSCAPING IN MODERN TIMES

    Directory of Open Access Journals (Sweden)

    Vaska Sandeva

    2017-02-01

    Full Text Available As we know we live in a process of industrialization and massive building of residential buildings, both individually and as a collective housing. Given all that happens even with the procedural other things to come up with all this, the country remains less green space that is required for a single environment, so the roof gardens are the best choice for all of this to get a beautiful country. For roof gardens should be given the explanation that, roof gardens, call it beautiful, flat roofs, and with gentle slope, with rich composition intensively maintained and often impose a constructive adaptation of the building and benefits by the architectural beauty, insulation, absorption. Commonly found in urban areas and almost always are placed foliage with not very high growth.

  12. Collaborative active roof design

    NARCIS (Netherlands)

    Quanjel, E.M.C.J.

    2008-01-01

    Roofs play an essential role in buildings. Their value and impact often significantly surpass the cost ratio they represent in the total investment cost of the building. Traditionally, roofs have a protecting function and their basic design has changed little over hundreds of years. Nowadays

  13. Development of industrial ion implantation and ion assisted coating processes: A perspective

    International Nuclear Information System (INIS)

    Legg, K.O.; Solnick-Legg, H.

    1989-01-01

    Ion beam processes have gone through a series of developmental stages, from being the mainstay of the semiconductor industry for production of integrated circuits, to new commercial processes for biomedical, aerospace and other industries. Although research is still continuing on surface modification using ion beam methods, ion implantation and ion assisted coatings for treatment of metals, ceramics, polymers and composites must now be considered viable industrial processes of benefit in a wide variety of applications. However, ion implantation methods face various barriers to acceptability, in terms not only of other surface treatment processes, but for implantation itself. This paper will discuss some of the challenges faced by a small company whose primary business is development and marketing of ion implantation and ion-assisted coating processes. (orig.)

  14. Natural gums of plant origin as edible coatings for food industry applications.

    Science.gov (United States)

    Saha, Anuradha; Tyagi, Shvetambri; Gupta, Rajinder K; Tyagi, Yogesh K

    2017-12-01

    Natural plant-based gums and their derivatives are widely utilized in food industries, however, their applications as edible coatings to extend fresh fruits and vegetable shelf-life has been explored recently. These natural polymeric polysaccharides have many advantages as compared to synthetic polymers, because they are biodegradable, nontoxic, economical and easily available in the environment. Natural gums can also be semi synthetically modified to produce derivatives, which can easily compete with the synthetic preservatives available on the food market. In this review, the recent developments in the use of natural gums and their derivatives as edible coatings have been explored and discussed.

  15. Plasma sprayed thermal barrier coatings for industrial gas turbines: morphology, processing and properties

    International Nuclear Information System (INIS)

    Gruenling, H.W.; Mannsmann, W.

    1993-01-01

    Thermal barrier coatings out of fully or partially stabilized zirconia offer a unique chance in gas turbines to increase the gas inlet temperature significantly while keeping the temperature of the structural material of the component within conventional limits. The protection of combustor parts and transition pieces as well as of some stationary gas turbine parts however is state of the art. As a consequence of still insufficient reliability, the application for hot rotating parts is very limited. The introduction as a design element requires safe life within defined time intervals. These depend on the overhaul and repair intervals of the engines. For large land based industrial or utility gas turbines, for example, coating life between 25.000 and 30.000 hrs. is a minimum requirement. Premature failure of a coating by e.g. local spalling causes local overheating of the component with the consequence of its total destruction or even more expensive secondary damages. Life limiting is the corrosion rate at the ceramic-metal interface and the behavior of the coated system under transient operating conditions, where multiaxial strain and stress distributions are generated. Sufficient strain tolerance of the coating both under tensile as well as compressive conditions is required. The properties of thermal barrier coating systems depend strongly on the structure and phase composition of the coating layers and the morphology of and the adhesion at the ceramic-metal interface. They have to be controlled by the process itself, the process parameters and the characteristics of the applied materials (e.g. chemical composition, processing, morphology, particle size and size distribution). It will be reviewed, how properties and structures of coating systems correlate and how structures can be modified by careful control of the process parameters. (orig.)

  16. Improved roof stabilization technologies

    International Nuclear Information System (INIS)

    Ebadian, M.A.

    1998-01-01

    Decontamination and decommissioning (D and D) activities require that personnel have access to all areas of structures, some of which are more than 40 years old. In many cases, these structures have remained in a standby condition for up to 10 years; few preventative maintenance activities have been performed on them because of lack of funding or a defined future plan of action. This situation has led to deteriorated building conditions, resulting in potential personnel safety hazards. In addition, leaky roofs allow water to enter the buildings, which can cause the spread of contamination and increase building deterioration, worsening the already unsafe working conditions. To ensure worker safety and facilitate building dismantlement, the assessment of roof stabilization techniques applicable to US Department of Energy (DOE) structures has become an important issue. During Fiscal year 1997 (FY97), a comprehensive reliability-based model for the structural stabilization analysis of roof system in complex structures was developed. The model consists of three major components: a material testing method, a deterministic structural computer model, and a reliability-based optimization, and probabilistic analyses of roof structures can be implemented. Given site-specific needs, this model recommends the most appropriate roof stabilization system. This model will give not only an accurate evaluation of the existing roof system in complex structures, but it will also be a reliable method to aid the decision-making process. This final report includes in its appendix a Users' Manual for the Program of Deterministic and Reliability Analysis of Roof Structures

  17. Norwegian Pitched Roof Defects

    Directory of Open Access Journals (Sweden)

    Lars Gullbrekken

    2016-06-01

    Full Text Available The building constructions investigated in this work are pitched wooden roofs with exterior vertical drainpipes and wooden load-bearing system. The aim of this research is to further investigate the building defects of pitched wooden roofs and obtain an overview of typical roof defects. The work involves an analysis of the building defect archive from the research institute SINTEF Building and Infrastructure. The findings from the SINTEF archive show that moisture is a dominant exposure factor, especially in roof constructions. In pitched wooden roofs, more than half of the defects are caused by deficiencies in design, materials, or workmanship, where these deficiencies allow moisture from precipitation or indoor moisture into the structure. Hence, it is important to increase the focus on robust and durable solutions to avoid defects both from exterior and interior moisture sources in pitched wooden roofs. Proper design of interior ventilation and vapour retarders seem to be the main ways to control entry from interior moisture sources into attic and roof spaces.

  18. New typologies for active roofs; An integral approach

    NARCIS (Netherlands)

    Zeiler, W.; Quanjel, E.M.C.J.; Borsboom, W.; Spoorenberg, H.

    2006-01-01

    A wide variety of new products, such as photovoltaic (PV) systems and solar collectors, roof lights, ventilation devices, insulation and safety devices, is finding its way into the roofing industry. As a result many problems occurred, resulting in poor quality, unsafe working conditions and high

  19. New typologies for active roofs; an integral approach

    NARCIS (Netherlands)

    Quanjel, E.M.C.J.; Borsboom, W.A.; Spoorenberg, H.H.R.

    2006-01-01

    A wide variety of new products, such as photovoltaic (PV) systems and solar collectors, roof lights, ventilation devices, insulation and safety devices, is finding its way into the roofing industry. As a result many problems occurred, resulting in poor quality, unsafe working conditions and high

  20. The Advancement of Cool Roof Standards in China from 2010 to 2015

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Jing [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Levinson, Ronnen M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-11-01

    Since the initiation of the U.S.-China Clean Energy Research Center-Building Energy Efficiency (CERC-BEE) cool roof research collaboration between the Lawrence Berkeley National Laboratory Heat Island Group and Chinese institutions in 2010, new cool surface credits (insulation trade- offs) have been adopted in Chinese building energy efficiency standards, industry standards, and green building standards. JGJ 75-2012: Design Standard for Energy Efficiency of Residential Buildings in Hot Summer and Warm Winter Zone became the first national level standard to provide cool surface credits. GB/T 50378-2014: Assessment Standard for Green Building is the first national level green building standard that offers points for heat island mitigation. JGJ/T 359-2015: Technical Specification for Application of Architectural Reflective Thermal Insulation Coating is the first industry standard that offers cool coating credits for both public and residential buildings in all hot-summer climates (Hot Summer/Cold Winter, Hot Summer/Warm Winter). As of December 2015, eight provinces or municipalities in hot-summer regions have credited cool surfaces credits in their residential and/or public building design standards; five other provinces or municipalities in hot-summer regions recommend, but do not credit, the use of cool surfaces in their building design standards. Cool surfaces could be further advanced in China by including cool roof credits for residential and public building energy efficiency standards in all hot-summer regions; developing a standardized process for natural exposure and aged-property rating of cool roofing products; and adapting the U.S.-developed laboratory aging process for roofing materials to replicate solar reflectance changes induced by natural exposure in China.

  1. Evaluation of the degradation of a zinc coating exposed to a damp industrial environment

    International Nuclear Information System (INIS)

    Naquid G, C.; Ayala R, V.

    2001-01-01

    The purpose of this work is to characterize and identify the degradation mechanism of a galvanized coating exposed to a dry arid industrial environment, but this one with events of high humidity (rains) and contaminated with copper salts. It was demonstrated that the atmospheric corrosion was accelerated by the presence of copper deposits and sulfur over the samples surface. Likewise it was tried to correlate the contact time (staying time) between the coating and the contaminated environment, the p H value (acid media) and the presence of salts (copper sulfates) in solution, with the deterioration grade of the galvanized coating. The analytical techniques applied in the study were: optical microscopy, scanning electron microscopy, X-ray diffraction and chemical analysis by X-ray dispersive energy spectroscopy. (Author)

  2. Green Roofs for Stormwater Management

    Science.gov (United States)

    This project evaluated green roofs as a stormwater management tool. Results indicate that the green roofs are capable of removing 40% of the annual rainfall volume from a roof through retention and evapotranspiration. Rainfall not retained by green roofs is detained, effectively...

  3. Green roofs; Les toitures vegetalisees

    Energy Technology Data Exchange (ETDEWEB)

    Seghier, C.

    2006-03-15

    Impervious surface coverage keeps spreading in cities. Streets, sidewalks, parking lots and roofs are waterproof, meaning greater amounts of water to channel and treat and higher flood risks during heavy rainfalls. Green roofing can play a key part in addressing this alarming issue. There are three types of green roofs: extensive, semi-intensive and intensive. The extensive green roof technique uses a thin soil covering with a variety of species providing year-round plant coverage. The plants are not necessarily horticultural in which case routine maintenance is minimal. No watering is needed. Usually extensive green roofs create an ecosystem. The semi-intensive green roof technique uses a soil covering of average thickness and serves to create decorative roofing. Although maintenance is moderate, watering is essential. The intensive green roof technique produces a terrace roof garden. Another advantage of green roofs is they increase the life cycle of the sealing. Roof sealing protection may see the span of its life cycle, now at about fifteen years, doubled if the building has a green roof. planning professionals still know very little about green roofing solutions. Yet, green roofing provides unquestionable ecological qualities and thermal and acoustic performance that have proven to be environmentally friendly. Yet France lags behind northern European countries in green roofing. The Germans, Swiss, Austrians, Scandinavians and Dutch have been using the technique for more than twenty years. (A.L.B.)

  4. Performance of antisolar insulated roof system

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Irshad [Alternative Energy Development Board (AEDB), House No. 1, Main Nazimuddin Road, F-10/4, Islamabad (Pakistan)

    2010-01-15

    Rooms with concrete slab roofs directly exposed to the sun become unbearably hot during summer and very cold during winter. Huge amounts of energy are required to keep them comfortable. Application of thermal insulation on roofs significantly reduces energy required for heating and cooling. The effectiveness of roof insulations may be further enhanced if a layer of antisolar coating is applied on top of the insulation. The antisolar coating reflects most of the incident sunlight and prevents the roof from heating up. This reduces the daily cycles of thermal expansion and contraction which cause cracks in the roof slabs for the rainwater to leak through. The antisolar coating prolongs the useful life of the building structure as well as the life of the insulation that evaporates with heat. The method of application of the antisolar coating has been specially developed to eliminate thermal bridges formed between the edges of the tiles. This report presents the results of an experiment conducted at the Attock Refinery Limited (ARL) Rawalpindi to assess the performance of the antisolar insulated roof system. Record of the room temperature before and after the installation of the system shows a significant reduction in the indoor temperature. The room occupants, who used to experience a very high thermal stress after 10:30 am in spite of the 1.5-ton air conditioner operating in the room, felt much relieved after the installation. They had to turn back the thermostat of the air conditioner and even had to switch it off occasionally. A detailed thermal analysis of the room shows that cost of an antisolar system is paid back in less than a year in the form of savings of energy required for air-conditioning in summer and for gas heating in winter. In addition, the system prevents the addition of 150 kg per year of green house gases to the atmosphere for each square meter of the area covered by the system. It also provides a quieter environment by reducing the operational

  5. BARRIERS TO THE USE OF RADIATION-CURABLE ADHESIVES IN THE COATED AND LAMINATED SUBSTRATE MANUFACTURING INDUSTRY

    Science.gov (United States)

    The paper gives results of an investigation of barriers to the use of radiation-cured technology in the coated and laminated substrate manufacturing industry. t presents information gathered from radiation-curable coating and equipment suppliers as well as technical publications....

  6. The technology of surface coatings by electron-beam (EB) with special reference to the wood industry

    International Nuclear Information System (INIS)

    Dahlan bin Haji Mohd

    1989-01-01

    The use of electron-beam as a processing means in surface coatings is discussed. Special attention has been given to this technology in relation to the surface coatings of wood. The main features of its technology and industrial requirements are outlined. (author)

  7. Effects of post-LOCA conditions on a protective coating (paint) for the Nuclear Power Industry

    International Nuclear Information System (INIS)

    Loyola, V.M.; Womelsduff, J.E.

    1985-03-01

    When corrosion protection of steel cannot be achieved by galvanizing due to size, use, or other restrictions, the steel is frequently protected by the application of a suitable corrosion-inhibiting paint. A widely accepted corrosion inhibiting coating is one in which finely powdered zinc metal is dispersed in an organic polymer matrix and applied to steel as a paint. This system is often used with a non-zinc bearing topcoat for enhanced protection. We have studied the oxidation of zinc in a zinc-rich coating used in the nuclear power industry and have measured the rates of hydrogen generation from these coatings due to zinc oxidation at temperatures of up to 175 0 C. The results suggest that the real-time rates of hydrogen generation are considerably higher than previously believed. A second concern involves the generation of debris or solid reaction products which could cause plugging or fouling of the recirculation pumps, spray nozzles, and/or heat exchangers. Coatings are observed to fail at post-LOCA conditions which are well within the limits predicted by Design Basis Accident analysis. The failures involve cracking and/or delamination of the topcoat and production of solid corrosion products involving the zinc-rich primer. 22 refs., 10 figs., 6 tabs

  8. Implementation of TiAIN and CrN coatings and ion implantation in the modern plastics moulding industry

    International Nuclear Information System (INIS)

    Bienk, E.J.; Mikkelsen, N.J.

    1997-01-01

    Two methods of surface improvement widely used in the modern plastics industry are compared, with a view to improving productivity and product quality. Ion implantation of plastics and physical vapour deposition coatings both offer surface engineering advantages. Each method is described and evaluated with reference to plastics moulding. TiAIN coatings are used to protect hard bulk materials, subjected to evenly distributed loads. The more ductile CrN coatings are used for softer materials which give less support to the coatings. (UK)

  9. Evolution of Flat Roofs

    Directory of Open Access Journals (Sweden)

    Şt. Vasiliu

    2009-01-01

    Full Text Available Roofs are constructive subassembles that are located at the top of buildings, which toghether with perimetral walls and some elements of the infrastructure belongs to the subsystem elements that close the building. Roofs must meet resistance requirements to mechanical action, thermal insulating, waterproofing and acoustic, fire resistance, durability, economy and aesthetics. The man saw the need to build roofs from the oldest ancient times. Even if the design of buildings has an empirical character, are known and are preserved until today constructions that are made in antiquity, by the Egyptians, Greeks and Romans with architectural achievements, worthy of admiration and in present time. General composition of civil construction has been influenced throughout the evolution of construction history by the level of production forces and properties of building materials available in every historical epoch. For over five millennia, building materials were stone, wood and ceramic products (concrete was used by theRomans only as filling material.

  10. Application of advanced coatings to narrow neck press and blow plungers in the glass container industry

    Energy Technology Data Exchange (ETDEWEB)

    Penlington, R. [Northumbria Univ., Newcastle upon Tyne (United Kingdom). Dept. of Mech. Eng. and Manufacturing Syst.; Sarwar, M. [Northumbria Univ., Newcastle upon Tyne (United Kingdom). Dept. of Mech. Eng. and Manufacturing Syst.; Lewis, D.B. [Sheffield Hallam Univ. (United Kingdom)

    1995-11-01

    Wear and failure modes exhibited by narrow neck press and blow (NNPB) plungers in the glass container industry have been related to inappropriate material selection. Problems exist with substrate and coating materials which lead to machine down time, process instability and poor product quality. Previous attempts to improve the service life of NNPB plungers have not examined the process operating characteristics and demanding nature of the application. New substrate and coating materials have been utilized and an assessment of their suitability for this application examined. Initial results from plant trials with modified plungers suggest that improvements in operational performance are achievable. This application, and other components of the mould tooling set, may benefit from improvements which may increase tool life and reduce the problems which result from the application of lubricant dopes to glass contact surfaces. (orig.)

  11. A Review of Methods for the Manufacture of Residential Roofing Materials

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Levinson, Ronnen; Berdahl, Paul

    2003-06-01

    Shingles, tiles, and metal products comprise over 80% (by roof area) of the California roofing market (54-58% fiberglass shingle, 8-10% concrete tile, 8-10% clay tile, 7% metal, 3% wood shake, and 3% slate). In climates with significant demand for cooling energy, increasing roof solar reflectance reduces energy consumption in mechanically cooled buildings, and improves occupant comfort in non-conditioned buildings. This report examines methods for manufacturing fiberglass shingles, concrete tiles, clay tiles, and metal roofing. The report also discusses innovative methods for increasing the solar reflectance of these roofing materials. We have focused on these four roofing products because they are typically colored with pigmented coatings or additives. A better understanding of the current practices for manufacturing colored roofing materials would allow us to develop cool colored materials creatively and more effectively.

  12. Green Roofs for Stormwater Runoff Control - Abstract

    Science.gov (United States)

    This project evaluated green roofs as a stormwater management tool. Specifically, runoff quantity and quality from green and flat asphalt roofs were compared. Evapotranspiration from planted green roofs and evaporation from unplanted media roofs were also compared. The influence...

  13. Photovoltaic roofing tile systems

    Science.gov (United States)

    Melchior, B.

    The integration of photovoltaic (PV) systems in architecture is discussed. A PV-solar roofing tile system with polymer concrete base; PV-roofing tile with elastomer frame profiles and aluminum profile frames; contact technique; and solar cell modules measuring technique are described. Field tests at several places were conducted on the solar generator, electric current behavior, battery station, electric installation, power conditioner, solar measuring system with magnetic bubble memory technique, data transmission via telephone modems, and data processing system. The very favorable response to the PV-compact system proves the commercial possibilities of photovoltaic integration in architecture.

  14. Industrial Wastes as Alternative Mineral Addition in Portland Cement and as Aggregate in Coating Mortars

    OpenAIRE

    Oliveira, Kamilla Almeida; Nazário, Bruna Inácio; Oliveira, Antonio Pedro Novaes de; Hotza, Dachamir; Raupp-Pereira, Fabiano

    2017-01-01

    This paper presents an evaluation study of wastes from pulp and paper as well as construction and demolition industries for application in cement-based materials. The alternative raw materials were used as a source of calcium carbonate (CaCO3) and as pozzolanic material (water-reactive SiO2) in partial replacement of Portland cement. In addition to the hydraulic binder, coating mortars were composed by combining the pulp and paper fluidized bed sand residue with construction and demolition wa...

  15. Assessment of Effectiveness of Cool Coat in Reducing Heat Strain among Workers in Steel Industry.

    Science.gov (United States)

    Parameswarappa, S B; Narayana, J

    2017-01-01

    A research study was conducted to assess the effectiveness of cool coat in reducing heat strain among workers exposed to heat in a steel plant located in south India. The study consists of assessing heat strain of workers exposed to heat in a steel plant by measuring physiological reactions of workers such as pulse rate and core body temperature with and without cool coat. The coal coat taken for this study was procured from M/s Yamuna Industries, Noida. Out of 140 employees exposed to heat hazard, 101 employees were examined in this study. Study was done in important production units in steel plant having heat hazard. Workers were interviewed and examined and information regarding thermal comfort was collected. First, the heat strain was assessed when the workers were not using cool coats. The air temperature was measured at all hot zone workplaces and found in the range of 34 0 C to 39.4 0 C (Mean: 36.54 0 C & S.D: 1.54). Physiological response such as core body temperature, pulse rate and blood pressure of workers exposed to heat hazard were measured before & after work to know the heat strain sustained by workers when they were working. Maximum core body temperature after work was found to be 39.3 0 C (Mean; 38.52 & S.D; 0.7). Maximum pulse rate of workers after work was found to be 120 beats/minute (Mean; 94.96 beats/minute, S.D: 13.11). The study indicate core body temperature of workers was found more than the permissible exposure limit prescribed by ACGIH, indicating the heat strain sustained by workers is significant, whereas the pulse rate and blood pressure was found normal & not exceeded the limits. Second, with cool coat, the heat strain was assessed among 10 workers selected from the 101 employees. Core body temperature was measured before and soon after work, The core body temperature recorded soon after work was in the range of 35.5 - 37.20C (Mean 36.36, SD= 0.52), indicating a drop in the core body temperature. In this study, a core body

  16. A novel in-line NIR spectroscopy application for the monitoring of tablet film coating in an industrial scale process.

    Science.gov (United States)

    Möltgen, C-V; Puchert, T; Menezes, J C; Lochmann, D; Reich, G

    2012-04-15

    Film coating of tablets is a multivariate pharmaceutical unit operation. In this study an innovative in-line Fourier-Transform Near-Infrared Spectroscopy (FT-NIRS) application is described which enables real-time monitoring of a full industrial scale pan coating process of heart-shaped tablets. The tablets were coated with a thin hydroxypropyl methylcellulose (HPMC) film of up to approx. 28 μm on the tablet face as determined by SEM, corresponding to a weight gain of 2.26%. For a better understanding of the aqueous coating process the NIR probe was positioned inside the rotating tablet bed. Five full scale experimental runs have been performed to evaluate the impact of process variables such as pan rotation, exhaust air temperature, spray rate and pan load and elaborate robust and selective quantitative calibration models for the real-time determination of both coating growth and tablet moisture content. Principal Component (PC) score plots allowed each coating step, namely preheating, spraying and drying to be distinguished and the dominating factors and their spectral effects to be identified (e.g. temperature, moisture, coating growth, change of tablet bed density, and core/coat interactions). The distinct separation of HPMC coating growth and tablet moisture in different PCs enabled a real-time in-line monitoring of both attributes. A PLS calibration model based on Karl Fischer reference values allowed the tablet moisture trajectory to be determined throughout the entire coating process. A 1-latent variable iPLS weight gain calibration model with calibration samples from process stages dominated by the coating growth (i.e. ≥ 30% of the theoretically applied amount of coating) was sufficiently selective and accurate to predict the progress of the thin HPMC coating layer. At-line NIR Chemical Imaging (NIR-CI) in combination with PLS Discriminant Analysis (PLSDA) verified the HPMC coating growth and physical changes at the core/coat interface during the initial

  17. Solar radiation on domed roofs

    Energy Technology Data Exchange (ETDEWEB)

    Faghih, Ahmadreza K.; Bahadori, Mehdi N. [School of Mechanical Engineering, Sharif University of Technology, Tehran (Iran)

    2009-11-15

    Solar radiation received and absorbed by four domed roofs was estimated and compared with that of a flat roof. The domed roofs all had the same base areas, and equal to that of the flat roof. One of the roofs considered was the dome of the St. Peter's Church in Rome. Compared with the other roofs considered, this dome had a higher aspect ratio. It was found that all domed roofs received more solar radiation than the flat roof. Considering glazed tiles to cover a selected dome in Iran and the dome of the St. Peter's Church, it was found that the solar radiation absorbed by these roofs is reduced appreciably. In the case of the dome of St. Peter's Church, the amount of radiation absorbed was roughly equal to that absorbed by the comparable flat roof in the warm months. In the case of the glazed reference dome located in Yazd, Iran (a city with very high solar radiation), the radiation absorbed was less than that of flat roof at all times. In addition to aesthetics, this may be a reason for employing glazed tiles to cover the domes of all mosques, shrines, and other large buildings in Iran. (author)

  18. Bio deterioration behaviour in different colour roofing tiles (red and straw coloured)

    International Nuclear Information System (INIS)

    Guzulla, M. F.; Sanchez, E.; Gonzalez, J. M.; Orduna, M.

    2014-01-01

    Bio colonization of building materials is a critical problem for the durability of constructions. Industrial experience shows that straw coloured roofing tiles are more prone to colonization than red roofing tiles, even having similar characteristics. The aim of this work is to explain the difference of bio colonization between different colour roofing tiles. The chemical composition of the surface of straw coloured and red roofing tiles, the phase composition and the microstructure of the roofing tiles were determined by WD-XRF, XRD and SEM-EDX, respectively. The pore size distribution was carried out by Hg porosimetry. The solubility was studied by determining the soluble salts (Ca, Mg, Na, K, Cl and SO 4 2-) by ICP-OES and ionic chromatography. Roofing tile bio receptivity was evaluated by determining fluorescence intensity using a pulse amplitude- modulated (PAM) fluoro meter, and cyanobacteria Oscillator sp. The results obtained show higher concentration of calcium and sulphur in straw coloured roofing tiles surface, and higher solubility than red roofing tiles. Moreover, according to the results obtained in bio receptivity assays, straw coloured roofing tiles are more prone to colonization than red roofing tiles, so, there is a relationship between surface properties of roofing tiles and bio colonization, as it is observed in industrial products. (Author)

  19. Bugs, bees and spiders : green roof design for rare invertebrates

    Energy Technology Data Exchange (ETDEWEB)

    Gedge, D. [Livingroofs.org, London (United Kingdom); Kadas, G. [Royal Holloway Univ. of London, London (United Kingdom)

    2004-07-01

    The use of green roofs as mitigation technique for biodiversity is particularly relevant for the objectives of the London Biodiversity Partnership, particularly since London is undergoing large-scale regeneration and many of the new developments will be targeted on brownfield land. In 2002 two research projects were undertaken to create a baseline of data on how invertebrates were using the current green roofs in London. The London Biodiversity Partnership's Black Redstart Action Plan conducts research into green roofs to demonstrate how they can be maximized for biodiversity. The Black Redstart Project ensures that green roofs are used in new developments in London where such developments threaten this species. It is one of the country's rarest breeding birds, and is unique in that it is predominantly found in cities, on brownfield sites and post-industrial sites. Three green roof laboratories were established at 2 sites in London to investigate how substrates, substrate depths and planting affects the fauna associated with brownfields and green roofs in London. Although conservationists in London have urged many developers to provide green roofs to help the Black Redstart, there is concern that many of these roofs do no provide the proper support for the species. In some cases roofs are constructed of commercially driven products such as sedum mats that do provide habitat for some rare invertebrates but are not as supportive of a greater diversity of species as they could be due to the design process and a lack of knowledge of green roof technology. It was suggested that there is a need for cooperation between ecologists and Architects in order to achieve the habitat. 18 refs., 6 figs.

  20. Hinged roof timber

    Energy Technology Data Exchange (ETDEWEB)

    Shestov, P I; Golub, A G; Yefremov, V I

    1980-08-07

    A hinged roof timer is suggested which includes a beam with prong and loop on the end which have openings in the form of ring slits for the distance wedges and round for the pins. In this case the opening of the distance wedge in the ring is arranged in relation to the opening for the pin closer to the end of the beam, and in the prong, in the opposite order. In order to improve the operating quality by guaranteeing active support of the cantilever roof timber without increasing its overall dimensions for the height of the opening for the distance wedge in the prong and the ring, beams are arranged axisymmetrically to the longitudinal axis.

  1. Historic timber roof structures

    OpenAIRE

    Magina, Miguel Jorge

    2013-01-01

    Dissertação para obtenção do Grau de Mestre em Engenharia Civil – Estruturas e Geotecnia This dissertation covers the study of historic timber roof structures in Transylvania area - Romania, the structures type, its elements and connection variety between them. Procedures to study a structure of this category are approached. It is also referred semi and non-destructive tests that can be done to better understand the present wood characteristics, and potential reparation or strengthening...

  2. Cool roofs in China: Policy review, building simulations, and proof-of-concept experiments

    International Nuclear Information System (INIS)

    Gao, Yafeng; Xu, Jiangmin; Yang, Shichao; Tang, Xiaomin; Zhou, Quan; Ge, Jing; Xu, Tengfang; Levinson, Ronnen

    2014-01-01

    While the concept of reflective roofing is not new to China, most Chinese cool roof research has taken place within the past decade. Some national and local Chinese building energy efficiency standards credit or recommend, but do not require, cool roofs or walls. EnergyPlus simulations of standard-compliant Chinese office and residential building prototypes in seven Chinese cities (Harbin, Changchun, Beijing, Chongqing, Shanghai, Wuhan, and Guangzhou) showed that substituting an aged white roof (albedo 0.6) for an aged gray roof (albedo 0.2) yields positive annual load, energy, energy cost, CO 2 , NO x , and SO 2 savings in all hot-summer cities (Chongqing, Shanghai, Wuhan, and Guangzhou). Measurements in an office building in Chongqing in August 2012 found that a white coating lowered roof surface temperature by about 20 °C, and reduced daily air conditioning energy use by about 9%. Measurements in a naturally ventilated factory in Guangdong Province in August 2011 showed that a white coating decreased roof surface temperature by about 17 °C, lowered room air temperature by 1–3 °C, and reduced daily roof heat flux by 66%. Simulation and experimental results suggest that cool roofs should be credited or prescribed in building energy efficiency standards for both hot summer/warm winter and hot summer/cold winter climates in China

  3. Green roofs: roof system reducing heating and cooling costs

    Directory of Open Access Journals (Sweden)

    Konasova, Sarka

    2016-06-01

    Full Text Available Green roofs are among the passive building systems that contribute to the thermal stability of the rooms under the roof in both summer and winter. Green roofs can provide a significant contribution to the thermal balance of the protected space. Over the past ten years, many studies have been carried out to investigate the energy benefits of green roofs in terms of the energy performance of buildings. These studies show that the installation of vegetated cover can achieve energy savings for both winter heating and summer cooling. The green roof, as a thermal insulation, reduces the amount of building operating energy costs and reduces heat losses. This article summarizes current literature and points to situations in which green roofs can play an important role in saving energy for heating and cooling due to improved thermal insulating function of the roof, in case of extensive vegetation coverage without significant overloading of the roof structure and associated over-dimensioning. It is important to note that these energy savings always depend on the particular climate, the type of building and the availability and the type of roof structure.

  4. Using Cool Roofs to Reduce Energy Use, Greenhouse Gas Emissions, and Urban Heat-island Effects: Findings from an India Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Xu, Tengfang; Taha, Haider; Wray, Craig; Sathaye, Jayant; Garg, Vishal; Tetali, Surekha; Babu, M. Hari; Reddy, K. Niranjan

    2011-05-25

    Cool roofs, cool pavements, and urban vegetation reduce energy use in buildings, lower local air pollutant concentrations, and decrease greenhouse gas emissions from urban areas. This report summarizes the results of a detailed monitoring project in India and related simulations of meteorology and air quality in three developing countries. The field results quantified direct energy savings from installation of cool roofs on individual commercial buildings. The measured annual energy savings potential from roof-whitening of previously black roofs ranged from 20-22 kWh/m2 of roof area, corresponding to an air-conditioning energy use reduction of 14-26% in commercial buildings. The study estimated that typical annual savings of 13-14 kWh/m2 of roof area could be achieved by applying white coating to uncoated concrete roofs on commercial buildings in the Metropolitan Hyderabad region, corresponding to cooling energy savings of 10-19%. With the assumption of an annual increase of 100,000 square meters of new roof construction for the next 10 years in the Metropolitan Hyderabad region, the annual cooling energy savings due to whitening concrete roof would be 13-14 GWh of electricity in year ten alone, with cumulative 10-year cooling energy savings of 73-79 GWh for the region. The estimated savings for the entire country would be at least 10 times the savings in Hyderabad, i.e., more than 730-790 GWh. We estimated that annual direct CO2 reduction associated with reduced energy use would be 11-12 kg CO2/m2 of flat concrete roof area whitened, and the cumulative 10-year CO2 reduction would be approximately 0.60-0.65 million tons in India. With the price of electricity estimated at seven Rupees per kWh, the annual electricity savings on air-conditioning would be approximately 93-101 Rupees per m2 of roof. This would translate into annual national savings of approximately one billion Rupees in year ten, and cumulative 10-year savings of over five billion Rupees for cooling

  5. Characterization and transformation of an industrial by-product (coated paper sludge into a pozzolanic material

    Directory of Open Access Journals (Sweden)

    San José, J. T.

    2007-03-01

    Full Text Available The effective re-use of industrial by-products calls for an understanding of their chemical, mineralogical and physical characteristics. The by-product used in this study was coated paper industry sludge from a plant whose sole prime material is recycled paper. Due to its high organic and calcium carbonate content and the presence of several clayey materials such as talc and kaolinite, incineration conditions had a significant effect on the mineralogy of such sludge. The present study examined the impact of such conditions on the pozzolanic properties of coated paper sludge. Several temperature intervals ranging from 600 to 750 ºC were studied to determine the conditions yielding the most promising pozzolanic properties.La necesidad de dar un correcto uso a los subproductos industriales requiere del conocimiento de sus características, tanto desde un punto de vista químico como mineralógico y físico. El subproducto utilizado para esta investigación es un lodo de papel estucado procedente de la industria papelera, la cual usa como materias primas un 100% de material reciclado. Debido al alto contenido de materia orgánica y carbonato cálcico y a la presencia de diferentes materiales arcillosos, como el talco y la caolinita, las condiciones de calcinación presentan un papel principal en la mineralogía de este lodo. En el actual trabajo se considera el papel que juegan estas condiciones, tiempo y permanencia en horno, en las propiedades puzolánicas del lodo de papel estucado como material cementante. Por esta razón, se estudiaron diferentes intervalos de temperatura, entre 600 y 750 ºC y 2 horas de permanencia en horno con el objetivo de obtener las mejores propiedades puzolánicas.

  6. An Insight into the Commercial Viability of Green Roofs in Australia

    Directory of Open Access Journals (Sweden)

    Nicole Tassicker

    2016-06-01

    Full Text Available Construction industries around the world have, in recent history, become increasingly concerned with the sustainability of building practices. Inherently, the development of the built environment results in partial or complete destruction of the natural environment. Advanced European and North American countries have turned to green roofs as a means of sustainable development. Australia, on the other hand, has yet to fully realize the potential of green roof technology. In the first case, an extensive review of green roof literature was undertaken to establish the dominant perspectives and over-riding themes within the established body of international literature. The collection of primary data took the form of qualitative, semi-structured interviews with a range of construction practitioners and green roof experts; landscape architects, consultants and academics. The information gained from the interviews facilitated the primary aim of the paper; to critically analyse the state-of-practice in the Australian green roof industry. Green roofs, despite their proven sustainability benefits and their international success, have experienced a relatively sluggish uptake in the Australian construction industry. With this being said, the Australian green roof industry is considered to have promising potential for the future; should there be legislative changes made in its favour or greater education within the industry. To advance the local industry, it was found that government authorities are required to adapt policy settings to better encourage the use of green roofs, whilst industry bodies are required to host better, more targeted educational programs.

  7. Toronto green roof construction standard

    International Nuclear Information System (INIS)

    Aster, D.

    2007-01-01

    Toronto City Council adopted a green roof strategy in February 2006. This paper reviewed the by-law governing the strategy as well as the work in progress to develop minimum standards for the design and construction of green roofs in Toronto. The strategy included a series of recommendations regarding the installation of green roofs on city buildings; a pilot grant program; using the development process to encourage green roofs; and, public education and promotion. It was noted that compared to Europe, the development of standards for green roofs in North America is in its early stages. As an emerging sustainable technology, there currently are no standards incorporated into Ontario's Building Code against which Toronto can measure the design and construction of green roofs. Therefore this paper included an analysis detailing how the recommended design requirements were able to support the City's green roof policy objectives and integrate the performance criteria for green roofs previously established and supported by Toronto City Council. The key policy objectives of the City's green roof strategy were to reduce the urban heat island effect; to address stormwater management implications in terms of quality and quantity; to improve the energy budgets of individual buildings; and, to improve air quality

  8. 30 CFR 75.205 - Installation of roof support using mining machines with integral roof bolters.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Installation of roof support using mining... Roof Support § 75.205 Installation of roof support using mining machines with integral roof bolters. When roof bolts are installed by a continuous mining machine with intregal roof bolting equipment: (a...

  9. Atmospheric corrosion resistance of epoxy duplex coated electrogalvanized steel exposed in marine, industrial and urban sites at pakistan

    International Nuclear Information System (INIS)

    Bano, H.; Kazmi, S.A.

    2017-01-01

    An epoxy based duplex coating system (Electrogalvanized Mild Steel/Etch Primer/Epoxy-Polyamide Primer/ Epoxy-Amine Topcoat System) embedded with iron oxide, zinc chromate and titanium dioxide pigments was studied to ascertain its corrosion resistant synergistic performance at various anthropogenic sites of Karachi coastal city while salt spray test was also executed for reference. Coating performance was ascertained by visual morphological inspection, gloss measurements, Scanning Electron Microscopy (SEM), Energy-Dispersive X-ray (EDX) analysis and by Fourier Transform Infrared (FTIR) Spectroscopy. SEM and EDX results corroborated high degradation of epoxy coating at marine site experiment as substantial increment in oxygen/carbon ratio and high concentration of Ti at coating surface due to ex-corporation of pigments were noticed. Worst performance of epoxy coating at marine test site as compared to salt spray testing may be due to the salt-laden winds of Karachi coastal city and corrosive constituents incorporated in atmospheres from industrial and automobiles exhaust. General diminution trend in gloss value, depletion of morphological features witnessed through SEM micrographs, curtailment of aryl ether and aromatic nuclei signals in FTIR spectrum, and emergence of new peaks in the 1620-1800 cm-1 region correspond to formation of new oxidation products; concluded that an insignificant protection offered by the epoxy coating due to its outdoor aging which led to ex-capsulation of pigments under moist conditions. Appraisal of these results have furnished an average coating performance correlation of 547.5 hpy (hours of salt spray test equivalence per year exposure test) at marine test site and 528 hpy at industrial test site in terms of blistering while equivalence mean in terms of rusting were found 680 hpy and 567 hpy at marine and industrial test sites respectively. (author)

  10. Nontraumatic orbital roof encephalocele.

    Science.gov (United States)

    Hoang, Amber; Maugans, Todd; Ngo, Thang; Ikeda, Jamie

    2017-02-01

    Intraorbital meningoencephaloceles occur most commonly as a complication of traumatic orbital roof fractures. Nontraumatic congenital orbital meningoncephaloceles are very rare, with most secondary to destructive processes affecting the orbit and primary skull defects. Treatment for intraorbital meningoencephaloceles is surgical repair, involving the excision of herniated brain parenchyma and meninges and reconstruction of the osseous defect. Most congenital lesions present in infancy with obvious globe and orbital deformities; we report an orbital meningoencephalocele in a 3-year-old girl who presented with ptosis. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  11. Standard practice for design and use of safety alert system for hazardous work locations in the coatings and lining industry

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This practice covers a safety alert system for hazardous work locations and materials for the coatings and lining application industry. This practice is designed for multi-employer work sites. Limitations--This practice does not identify specific hazardous materials or work locations but provides a means for rating each. This standard may involve hazardous materials, operations, and equipment

  12. Green roofs and the LEED green building rating system

    Energy Technology Data Exchange (ETDEWEB)

    Kula, R. [Sustainable Solutions Inc., Wagoner, OK (United States)

    2005-07-01

    The sustainable building industry is becoming increasingly aware of the host of public and private benefits that green roofs can provide in built environments. In dense urban environments, green roofs function to reduce stormwater runoff, urban heat island effects, and particulate matter (PM) pollution. The emerging green roof industry is now poised to support the efforts of green building networks in North America. This paper discussed the general benefits of green roofs, and their recognition within the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. A case study of Mountain Equipment Co-op's Winnipeg site was presented. The building's green roof was directly responsible for earning 5 credits and contributing to the achievement of an additional 2 credits under the LEEDS certification process. Credits were earned for reduced site disturbance; landscape design to reduce heat islands; and water efficiency. The green roof at the site provided the vast majority of the building's cooling needs through an evaporative cooling trough. A photovoltaic pump was used to feed the building's irrigation system, as well as to pump ground water through cooling valances. It was concluded that the rise of sustainable building practices and the LEED Green Building Rating System will revolutionize the way new buildings are constructed.

  13. An eye for the green top : an independent voice for green roofs in the UK

    Energy Technology Data Exchange (ETDEWEB)

    Frith, M.; Gedge, D. [Livingroofs.org, England (United Kingdom)

    2005-07-01

    Livingroofs.org is a non-profit organization that was established to provide a resource for promoting green roofs in the United Kingdom (UK). Current policies in the UK related to the planning and development of green roofs are a constraint to their uptake. The emerging emphasis on sustainable development is bringing about a revision of planning policies that may make green roofs more desirable. However, green roof design standards are still being developed by a largely unmonitored industry furthering a product with which most people are unfamiliar. This paper reviewed a number of issues that need to be addressed to assist in the wider adoption of green roofs, including increased awareness; an identification of the real benefits of green roofs; guidance and research; planning policies; fiscal incentives; industry standards and codes of practice. Details of the current policy frameworks for construction, urban design and climate change were also outlined. Two specific projects were reviewed to provide an insight into the way in which Livingroofs.org intends to promote green roof technology: a roof owned by the Birmingham city council and a collaboration with a Swiss partner to design a roof for the Komodo Dragon House at the London Zoo. It was concluded that there is now a real likelihood that the widespread adoption of green roofs will occur in the UK within the next 5 years, both in terms of new developments and the vast potential for retro-fitting on existing buildings. 47 refs., 2 tabs.

  14. A Roof for the Lion's House

    Science.gov (United States)

    1978-01-01

    Fans of the National Football League's Detroit Lions don't worry about gameday weather. Their magnificent new Pontiac Stadium has a domed, air-supported, fabric roof that admits light but protects the playing field and patrons from the elements. The 80,000-seat "Silverdome" is the world's largest fabric-covered structure-and aerospace technology played an important part in its construction. The key to economical construction of the Silverdome-and many other types of buildings-is a spinoff of fiber glass Beta yarn coated with Teflon TFE fluorocarbon resin. The big advance it offers is permanency. Fabric structures-tents, for example have been around since the earliest years of human civilization. But their coverings-hides, canvas and more recently plastics-were considered temporary; though tough, these fabrics were subject to weather deterioration. Teflon TFE-coated Beta Fiberglas is virtually impervious to the effects of weather and sunlight and it won't stretch, shrink, mildew or rot, thus has exceptional longevity; it is also very strong, lightweight, flame resistant and requires no periodic cleaning, because dirt will not stick to the surface of Teflon TFE. And to top all that, it costs only 30 to 40 percent as much as conventional roofing.

  15. Condition Assessment Survey (CAS) Program. Deficiency standards and inspections methods manual: Volume 5, 0.05 Roofing

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    General information is presented for asset determinant factor/CAS repair codes/CAS cost factors; guide sheet tool & material listing; testing methods; inspection frequency; standard system design life tables; and system work breakdown structure. Deficiency standards and inspection methods are presented for built-up membrane; single- ply membrane; metal roofing systems; coated foam membrane; shingles; tiles; parapets; roof drainage system; roof specialties; and skylights.

  16. Green roofs: potential at LANL

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Elena M [Los Alamos National Laboratory

    2009-01-01

    Green roofs, roof systems that support vegetation, are rapidly becoming one of the most popular sustainable methods to combat urban environmental problems in North America. An extensive list of literature has been published in the past three decades recording the ecological benefits of green roofs; and now those benefits have been measured in enumerated data as a means to analyze the costs and returns of green roof technology. Most recently several studies have made substantial progress quantifying the monetary savings associated with storm water mitigation, the lessoning of the Urban Heat Island, and reduction of building cooling demands due to the implementation of green roof systems. Like any natural vegetation, a green roof is capable of absorbing the precipitation that falls on it. This capability has shown to significantly decrease the amount of storm water runoff produced by buildings as well as slow the rate at which runoff is dispensed. As a result of this reduction in volume and velocity, storm drains and sewage systems are relieved of any excess stress they might experience in a storm. For many municipalities and private building owners, any increase in storm water mitigation can result in major tax incentives and revenue that does not have to be spent on extra water treatments. Along with absorption of water, vegetation on green roofs is also capable of transpiration, the process by which moisture is evaporated into the air to cool ambient temperatures. This natural process aims to minimize the Urban Heat Island Effect, a phenomenon brought on by the dark and paved surfaces that increases air temperatures in urban cores. As the sun distributes solar radiation over a city's area, dark surfaces such as bitumen rooftops absorb solar rays and their heat. That heat is later released during the evening hours and the ambient temperatures do not cool as they normally would, creating an island of constant heat. Such excessively high temperatures induce heat

  17. Sheffield's Green Roof Forum: a multi-stranded programme of green roof infrastructure development for the UK's greenest city

    International Nuclear Information System (INIS)

    Dunnett, N.

    2006-01-01

    Sheffield, United Kingdom (UK) was the world centre for the steel and cutlery industries. However, those industries have been in decline and the city has been in the process of re-inventing itself over the past 20 years. Sheffield is now known as the UK's greenest city in terms of the amount of woodland, parkland and open spaces within its city limits. The city of Sheffield has also developed a unique partnership approach to promote green roof infrastructure as the most visible and high-profile signal of intent and symbol of low environmental impact building design and construction. This partnership involves Sheffield's Green Roof Forum, comprising the University of Sheffield's multi-disciplinary centre of excellence in green roof research; Sheffield City Council; Groundwork Sheffield, an urban economic and environmental regeneration agency; and city Architects and developers. This partnership meets six times a year to raise the profile of green roofs within the city and region, and to develop strategies to increase the uptake and implementation of green roof infrastructure in the region. This paper discussed the partnership, the Green Room Forum, accomplishments to date in promoting green roofs in the city, and the strategy for the Sheffield region to become a leader in green roof implementation and associated green technologies. The strategy is presented in two parts: consultation and research to identify the nature of market failure and devising methods to overcome that failure. The green roof strategy is being implemented through a program entitled Building Greener, Building Smarter and consists of four inter-linked strands. These strands were discussed in detail and included getting buy-in, demonstrating benefit, establishing the business case, and changing plans and practices. 3 tabs., 1 ref

  18. Energy roofs. Energiedaken

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    Low grade heat from roofs and walls can be upgraded to useful temperatures by heat pumps. Even latent heat can be used. This report gives a survey of the possibilities to use these forms of heat in houses. Several types of heat pumps are described; working of heat absorbers is explained and cost aspects are discussed. Absorbers are less sensitive for shadows than solar collectors, which is a remarkable advantage in urban areas where high-rise building is employed. Application of solar absorbers is closely connected to heat pumps. Both absorber systems and heat pumps are so expensive that the costs are now prohibitive when gas is available, but this is due to small production series. Construction and materials make cheaper production possible when demand increases. (A.V.)

  19. Industrial Market Research Report: Feasibility of commercialization of the advanced antifouling coating of Copperlok, Inc.

    Energy Technology Data Exchange (ETDEWEB)

    Gormley, G.J.

    1990-10-01

    The Copperlok antifouling process was designed to prevent marine growth on surfaces exposed to sea water. It is a method of bonding thermally sprayed Cu and Cu alloys onto an epoxy material containing microballoons (hollow spheres). After the epoxy cures, the surface is abraded so that the microballoons are fractured, exposing microscopic concave porosity. The sprayed material is directed to the surface, where it impregnates the pores, bridges and then welds across the surface, creating a very thin laminate of the metal materials security bonded to the bond coat and to the substrate. The Copperlok process laminates an approximate layer of Cu-Ni alloy 8 mils thick with an expected active life of 15--20 y. This report addresses the perceived acceptability of the process in several different marketplaces with the hope of directing the invention to the most receptive consumer group. The opinion surveys of the recreational marine industry were limited to the three coastal areas of the Atlantic, Gulf, and Pacific.

  20. Industrial Market Research Report: Feasibility of commercialization of the advanced antifouling coating of Copperlok, Inc

    Energy Technology Data Exchange (ETDEWEB)

    Gormley, G.J.

    1990-10-01

    The Copperlok antifouling process was designed to prevent marine growth on surfaces exposed to sea water. It is a method of bonding thermally sprayed Cu and Cu alloys onto an epoxy material containing microballoons (hollow spheres). After the epoxy cures, the surface is abraded so that the microballoons are fractured, exposing microscopic concave porosity. The sprayed material is directed to the surface, where it impregnates the pores, bridges and then welds across the surface, creating a very thin laminate of the metal materials security bonded to the bond coat and to the substrate. The Copperlok process laminates an approximate layer of Cu-Ni alloy 8 mils thick with an expected active life of 15--20 y. This report addresses the perceived acceptability of the process in several different marketplaces with the hope of directing the invention to the most receptive consumer group. The opinion surveys of the recreational marine industry were limited to the three coastal areas of the Atlantic, Gulf, and Pacific.

  1. Modelling reduction of urban heat load in Vienna by modifying surface properties of roofs

    Science.gov (United States)

    Žuvela-Aloise, Maja; Andre, Konrad; Schwaiger, Hannes; Bird, David Neil; Gallaun, Heinz

    2018-02-01

    The study examines the potential of urban roofs to reduce the urban heat island (UHI) effect by changing their reflectivity and implementing vegetation (green roofs) using the example of the City of Vienna. The urban modelling simulations are performed based on high-resolution orography and land use data, climatological observations, surface albedo values from satellite imagery and registry of the green roof potential in Vienna. The modelling results show that a moderate increase in reflectivity of roofs (up to 0.45) reduces the mean summer temperatures in the densely built-up environment by approximately 0.25 °C. Applying high reflectivity materials (roof albedo up to 0.7) leads to average cooling in densely built-up area of approximately 0.5 °C. The green roofs yield a heat load reduction in similar order of magnitude as the high reflectivity materials. However, only 45 % of roof area in Vienna is suitable for greening and the green roof potential mostly applies to industrial areas in city outskirts and is therefore not sufficient for substantial reduction of the UHI effect, particularly in the city centre which has the highest heat load. The strongest cooling effect can be achieved by combining the green roofs with high reflectivity materials. In this case, using 50 or 100 % of the green roof potential and applying high reflectivity materials on the remaining surfaces have a similar cooling effect.

  2. Green Roofs for Stormwater Runoff Control

    Science.gov (United States)

    This project evaluated green roofs as a stormwater management tool. Specifically, runoff quantity and quality from green and flat asphalt roofs were compared. Evapotranspiration from planted green roofs and evaporation from unplanted media roofs were also compared. The influence...

  3. 30 CFR 75.204 - Roof bolting.

    Science.gov (United States)

    2010-07-01

    ... accessories addressed in ASTM F432-95, “Standard Specification for Roof and Rock Bolts and Accessories,” the.... (4) In each roof bolting cycle, the actual torque or tension of the first tensioned roof bolt... during each roof bolting cycle shall be tested during or immediately after the first row of bolts has...

  4. Evaluation of Moisture-Cure Urethane Coatings for Compliance with Industry Specifications

    Science.gov (United States)

    2011-12-01

    polyurethane coating with a thermoset binder and micaceous iron oxide pigment reinforcement. Since SSPC paint specifications are designed for zinc ...Outside Coating System No.2 (minimum AWWA OFT 7.5 mils) 1 ct. Corothane I GalvaPac Zinc Primer@ 3.0 mils dft 1 ct. Corothane Iron ox B@ 3.0 mils dft...Substrates Over properly prepared: Ferrous Metal Galvanized Metal Aluminium/Non-Ferrous Metal Ductile Iron Previously Existing Coatings

  5. Selection of powered roof support for weak coal roof

    Energy Technology Data Exchange (ETDEWEB)

    Ramayya, M.S.V.; Sudhakar, L. [Singareni Collieries Co. Ltd., Kothagudem (India)

    2002-04-01

    Singareni Collieries Company Ltd (SCCL) introduced mechanised longwall mining in 1983. The first few faces were worked with conventional and immediate forward supports (IFS), with capacities in the range of 360 to 450 t. These under capacity supports increased from abutment loads and there was breakage of roof in front of the supports which resulted in closure of powered roof supports, followed by face cavities. The cavities were more frequent and were difficult to negotiate especially in case of IFS supports. Subsequently, support capacity was increased at Padmavati Khani (PVK) mine and at GDK.10a and GKD.9LFP Inclines where the roof is composed of weak, coal, shale and clay. Problems related to failure of hydraulics/legs etc., which are repairable have occurred; though the problems are not totally eliminated, there was definite improvement in strata control with these higher capacity supports. Monitoring of supports was conducted all through the working of longwall panels. The data generated while working these longwall faces were analysed to study the suitability of other types of powered roof supports, namely 2 legged shield supports/4 legged supports for improved strata control. The analysis and practical experiences suggest that in weak, coaly, shale and clay roofs 2 legged shield supports offer better roof control. 4 refs., 4 figs.

  6. ENERGY STAR Certified Roof Products

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.0 ENERGY STAR Program Requirements for Roof Products that are effective as of July 1,...

  7. Run-off from roofs

    International Nuclear Information System (INIS)

    Roed, J.

    1985-01-01

    In order to find the run-off from roof material a roof has been constructed with two different slopes (30 deg C and 45 deg C). Beryllium-7 and caesium-137 has been used as tracers. Considering new roof material the pollution removed by runoff processes has been shown to be very different for various roof materials. The pollution is much more easily removed from silicon-treated material than from porous red-tile roof material. Caesium is removed more easily than beryllium. The content of caesium in old roof materials is greater in red-tile than in other less-porous materials. However, the measured removal from new material does not correspond to the amount accumulated in the old. This could be explained by weathering and by saturation effects. This last effect is probably the more important. The measurements on old material indicates a removal of 44-86% of the caesium pollution by run-off, whereas the measurement on new showed a removal of only 31-50%. It has been demonstrated that the pollution concentration in the run-off water could be very different from that in rainwater. The work was part of the EEC Radiation Protection Programme and done under a subcontract with Association Euratom-C.E.A. No. SC-014-BIO-F-423-DK(SD) under contract No. BIO-F-423-81-F. (author)

  8. [A review of green roof performance towards management of roof runoff].

    Science.gov (United States)

    Chen, Xiao-ping; Huang, Pei; Zhou, Zhi-xiang; Gao, Chi

    2015-08-01

    Green roof has a significant influence on reducing runoff volume, delaying runoff-yielding time, reducing the peak flow and improving runoff quality. This paper addressed the related research around the world and concluded from several aspects, i.e., the definition of green roof of different types, the mechanism how green roof manages runoff quantity and quality, the ability how green roof controls roof runoff, and the influence factors of green roof toward runoff quantity and quality. Afterwards, there was a need for more future work on research of green roof toward roof runoff, i.e., vegetation selection of green roof, efficient construction model selection of green roof, the regulating characteristics of green roof on roof runoff, the value assessment of green roof on roof runoff, analysis of source-sink function of green roof on the water pollutants of roof runoff and the research on the mitigation measures of roof runoff pollution. This paper provided a guideline to develop green roofs aiming to regulating roof runoff.

  9. Nanoparticles in facade coatings: a survey of industrial experts on functional and environmental benefits and challenges

    International Nuclear Information System (INIS)

    Hincapié, Ingrid; Künniger, Tina; Hischier, Roland; Cervellati, Dario; Nowack, Bernd; Som, Claudia

    2015-01-01

    Integrating engineered nanoparticles (ENPs) into facade coatings is expected to offer considerable potential for improved or novel functionality, or even several functionalities at the same time (multifunctional materials). Little information is available about the tangible use of ENPs in facade coatings and the real improvements that their functionalities provide. In order to increase this information, we carried out a survey among selected coating manufacturers and ENP producers in Europe. We asked them about the improved functionalities enabled by ENPs, the quality of nano-enhanced facade coatings in comparison to conventional ones, and the handling of waste. The survey results indicated that the ENPs most frequently used in facade coatings in Europe were silver, titanium dioxide, and silicon dioxide. The most frequently mentioned potential benefits were ultraviolet-protection, water and dirt repellency (easy to clean), and antimicrobial properties. Improving environmental performance through the use of nano-enhanced facade coatings did not appear to be a focus for innovation. The survey also revealed mixed results in the comparison between nano-enhanced and conventional facade coatings: 36 % of respondents saw a notable improvement, 27 % noted a gradual improvement of functionalities, and 37 % detected no improvement over traditional materials. Some respondents mentioned a variety of tests that can be applied to investigate the quality of coating functionalities. These tests could be valuable in helping us to better understand the tangible improvements of nano-enhanced facade coating functionalities. Respondents were uncertain about how to properly handle the wastes resulting from nano-enhanced products

  10. Nanoparticles in facade coatings: a survey of industrial experts on functional and environmental benefits and challenges

    Energy Technology Data Exchange (ETDEWEB)

    Hincapié, Ingrid [EMPA Swiss Federal Laboratories for Materials Science and Technology, Technology and Society Laboratory (Switzerland); Künniger, Tina [EMPA Swiss Federal Laboratories for Materials Science and Technology, Applied Wood Materials Laboratory (Switzerland); Hischier, Roland [EMPA Swiss Federal Laboratories for Materials Science and Technology, Technology and Society Laboratory (Switzerland); Cervellati, Dario [GFC Chimica S.r.l (Italy); Nowack, Bernd; Som, Claudia, E-mail: claudia.som@empa.ch [EMPA Swiss Federal Laboratories for Materials Science and Technology, Technology and Society Laboratory (Switzerland)

    2015-07-15

    Integrating engineered nanoparticles (ENPs) into facade coatings is expected to offer considerable potential for improved or novel functionality, or even several functionalities at the same time (multifunctional materials). Little information is available about the tangible use of ENPs in facade coatings and the real improvements that their functionalities provide. In order to increase this information, we carried out a survey among selected coating manufacturers and ENP producers in Europe. We asked them about the improved functionalities enabled by ENPs, the quality of nano-enhanced facade coatings in comparison to conventional ones, and the handling of waste. The survey results indicated that the ENPs most frequently used in facade coatings in Europe were silver, titanium dioxide, and silicon dioxide. The most frequently mentioned potential benefits were ultraviolet-protection, water and dirt repellency (easy to clean), and antimicrobial properties. Improving environmental performance through the use of nano-enhanced facade coatings did not appear to be a focus for innovation. The survey also revealed mixed results in the comparison between nano-enhanced and conventional facade coatings: 36 % of respondents saw a notable improvement, 27 % noted a gradual improvement of functionalities, and 37 % detected no improvement over traditional materials. Some respondents mentioned a variety of tests that can be applied to investigate the quality of coating functionalities. These tests could be valuable in helping us to better understand the tangible improvements of nano-enhanced facade coating functionalities. Respondents were uncertain about how to properly handle the wastes resulting from nano-enhanced products.

  11. Application of Spray Foam Insulation Under Plywood and Oriented Strand Board Roof Sheathing

    Energy Technology Data Exchange (ETDEWEB)

    Grin, A. [Building Science Corporation, Somerville, MA (United States); Smegal, J. [Building Science Corporation, Somerville, MA (United States); Lstiburek, J. [Building Science Corporation, Somerville, MA (United States)

    2013-10-01

    Unvented roof strategies with open cell and closed cell spray polyurethane foam insulation sprayed to the underside of roof sheathing have been used since the mid-1990's to provide durable and efficient building enclosures. However, there have been isolated moisture related incidents reported anecdotally that raise potential concerns about the overall hygrothermal performance of these systems. This project involved hygrothermal modeling of a range of rainwater leakage and field evaluations of in-service residential roofs using spray foam insulation. All of the roof assemblies modeled exhibited drying capacity to handle minor rainwater leakage. All field evaluation locations of in-service residential roofs had moisture contents well within the safe range for wood-based sheathing. Explorations of eleven in-service roof systems were completed. The exploration involved taking a sample of spray foam from the underside of the roof sheathing, exposing the sheathing, then taking a moisture content reading. All locations had moisture contents well within the safe range for wood-based sheathing. One full-roof failure was reviewed, as an industry partner was involved with replacing structurally failed roof sheathing. In this case the manufacturer's investigation report concluded that the spray foam was installed on wet OSB based on the observation that the spray foam did not adhere well to the substrate and the pore structure of the closed cell spray foam at the ccSPF/OSB interface was indicative of a wet substrate.

  12. Comparison of Software Models for Energy Savings from Cool Roofs

    Energy Technology Data Exchange (ETDEWEB)

    New, Joshua Ryan [ORNL; Miller, William A [ORNL; Huang, Yu (Joe) [White Box Technologies; Levinson, Ronnen [Lawrence Berkeley National Laboratory (LBNL)

    2014-01-01

    A web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs modern web technologies, usability design, and national average defaults as an interface to annual simulations of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim in order to provide estimated annual energy and cost savings. In addition to cool reflective roofs, RSC simulates multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. A base case and energy-efficient alternative can be compared side-by-side to estimate monthly energy. RSC was benchmarked against field data from demonstration homes in Ft. Irwin, California; while cooling savings were similar, heating penalty varied significantly across different simulation engines. RSC results reduce cool roofing cost-effectiveness thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC s projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus, and presents preliminary analyses. RSC s algorithms for capturing radiant heat transfer and duct interaction in the attic assembly are considered major contributing factors to increased cooling savings and heating penalties. Comparison to previous simulation-based studies, analysis on the force multiplier of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model are included.

  13. Composite polymer-containing coatings on Mg alloys perspective for industry and implant surgery

    Science.gov (United States)

    Gnedenkov, S. V.; Sinebryukhov, S. L.; Mashtalyar, D. V.; Imshinetskiy, I. M.; Gnedenkov, A. S.; Minaev, A. N.

    2017-09-01

    In order to improve the corrosion resistance of magnesium alloys the ways of composite protective coating formation were developed by means of plasma electrolytic oxidation (PEO) as well as electrophoretic deposition methods. Electrochemical, corrosion, tribological, and morphological properties of the MAS magnesium alloy composite coatings were studied. The composite polymer-containing coating decrease the corrosion current density values by three orders of magnitude (Ic = 2.0 . 10-10 A/cm2), in comparison with the base PEO-layer. These polymer-containing layers enable one to expand the practical usage area of Mg alloys. The application of such coatings provides the increasing the bioactivity and regulate the corrosion rate of resorbable magnesium implants.

  14. Smart Multifunctional Coatings for Corrosion Detection and Control in the Aerospace Industry

    Science.gov (United States)

    Calle, Luz Marina

    2015-01-01

    Nearly all metals and their alloys are subject to corrosion that causes them to lose their structural integrity or other critical functionality. It is essential to detect corrosion when it occurs, and preferably at its early stage, so that action can be taken to avoid structural damage or loss of function. Protective coatings are the most commonly used method of corrosion control. However, progressively stricter environmental regulations have resulted in the ban of many commercially available corrosion protective coatings due to the harmful effects of their solvents or corrosion inhibitors. This work concerns the development of a multifunctional, smart coating for the autonomous control of corrosion. This coating is being developed to have the inherent ability to detect the chemical changes associated with the onset of corrosion and respond autonomously to indicate it and control it.

  15. Sol gel coatings doped with Ce ions deposited on industrial applications metals

    International Nuclear Information System (INIS)

    Pepe, A; Aparicio, M; Duran, A; Cere, S

    2004-01-01

    Compounds that contain chromates as corrosion inhibitors are widely used. Since these compounds are highly toxic, enormous efforts are being made to replace them. The lanthanides, especially cerium, have the right properties for this substitution. Different substrates can be protected by a variety of coatings. The sol-gel derived films can be deposited on different metals or alloys to increase their resistance to corrosion or to modify their surface properties by doped with different substances that can increase their protective strength, by combining the barrier capacity of the hybrid coating with the inhibitory properties of the cerium. This work presents the conditions for obtaining soles doped with cerium III and IV salts at room temperature and humidity. The parameters are also described for obtaining coatings by free immersion-extraction of fissures and pores on metallic substrates (stainless steel AISI 304). The behavior with corrosion of the coated samples was characterized with electrochemical tests (CW)

  16. Applications in the Nuclear Industry for Thermal Spray Amorphous Metal and Ceramic Coatings

    OpenAIRE

    Blink, J.; Farmer, J.; Choi, J.; Saw, C.

    2009-01-01

    Amorphous metal and ceramic thermal spray coatings have been developed with excellent corrosion resistance and neutron absorption. These coatings, with further development, could be cost-effective options to enhance the corrosion resistance of drip shields and waste packages, and limit nuclear criticality in canisters for the transportation, aging, and disposal of spent nuclear fuel. Iron-based amorphous metal formulations with chromium, molybdenum, and tungsten have shown the corrosion resis...

  17. Biocompatible antimicrobial cotton fibres for healthcare industries: a biogenic approach for synthesis of bio-organic-coated silver nanoparticles.

    Science.gov (United States)

    Kashid, Sahebrao B; Lakkakula, Jaya R; Chauhan, Deepak S; Srivastava, Rohit; Raut, Rajesh W

    2017-12-01

    Cotton fibres coated with biogenically fabricated silver nanoparticles (SNPs) are most sought material because of their enhanced activity and biocompatibility. After successful synthesis of SNPs on cotton fibres using leaf extract of Vitex negundo Linn, the fibres were studied using diffuse reflectance spectroscopy, scanning electron microscopy, nanoparticle tracking analysis, energy dispersive X-ray, and inductively coupled plasma atomic emission spectrometry. The characterisation revealed uniformly distributed spherical agglomerates of SNPs having individual particle size around 50 nm with the deposition load of 423 μg of silver per gram of cotton. Antimicrobial assay of cotton-SNPs fibres showed effective performance against pathogenic bacteria and fungi. The method is biogenic, environmentally benign, rapid, and cost-effective, producing highly biocompatible antimicrobial coating required for the healthcare industry.

  18. Performance Analysis of Cool Roof, Green Roof and Thermal Insulation on a Concrete Flat Roof in Tropical Climate

    OpenAIRE

    Zingre, Kishor T.; Yang, Xingguo; Wan, Man Pun

    2015-01-01

    In the tropics, the earth surface receives abundant solar radiation throughout the year contributing significantly to building heat gain and, thus, cooling demand. An effective method that can curb the heat gains through opaque roof surfaces could provide significant energy savings. This study investigates and compares the effectiveness of various passive cooling techniques including cool roof, green roof and thermal insulation for reducing the heat gain through a flat concrete roof in tropic...

  19. Lifetime modelling for MCrAlY coatings in industrial gas turbine blades

    Directory of Open Access Journals (Sweden)

    Krukovsky Pavel

    2004-01-01

    Full Text Available A novel theoretical and experimental approach for lifetime modelling of MCrAlY coatings for stationary gas turbines has been undertaken using the Inverse Problem Solution (IPS technique. With this technique feasible experimental data acquired after a defined experimental time t e are used as input values for the model parameters estimation. In the first stage of the approach a model, based on the oxidation and diffusion processes (Fick's first and second law was assumed, which considers the Al concentration profile across the coating. The measured average Al concentration profiles in the two-phase g+b and g - regions of coating as well as base metal were used as input values for the model parameters estimation and calculational prediction of the long term diffusion and oxidation behavior of the coating was performed. The time, when the b-NiAl phase is completely consumed was assumed as the coating lifetime end. Exposure experiments were carried out with a NiCoCrAlY coating (200 micron thickness with 8% Al in air at 900 °C and 950 °C, currently up to 10000 h. The oxide scale is growing continuously and no other oxides were observed. The average and b-NiAl phase concentration profiles of Al across the coating thickness were determined by electron microprobe and image analysis systems in the initial state after 700 and 10000 h of oxidation. The concentration profile measured after 700 h was used as input values for the model parameters estimation in order to calculate the Al and b-NiAl phase concentration profiles after 10000 h. The computational forecast for 10000 h at 950 °C and 900 °C are in good agreement with the measured data. The approach was applied for NiCoCrAlY (200 micron thickness coating lifetime modelling at 950 °C and 900 °C as well as for different coating thicknesses at 950 °C.

  20. Applications in the Nuclear Industry for Thermal Spray Amorphous Metal and Ceramic Coatings

    Science.gov (United States)

    Blink, J.; Farmer, J.; Choi, J.; Saw, C.

    2009-06-01

    Amorphous metal and ceramic thermal spray coatings have been developed with excellent corrosion resistance and neutron absorption. These coatings, with further development, could be cost-effective options to enhance the corrosion resistance of drip shields and waste packages, and limit nuclear criticality in canisters for the transportation, aging, and disposal of spent nuclear fuel. Iron-based amorphous metal formulations with chromium, molybdenum, and tungsten have shown the corrosion resistance believed to be necessary for such applications. Rare earth additions enable very low critical cooling rates to be achieved. The boron content of these materials and their stability at high neutron doses enable them to serve as high efficiency neutron absorbers for criticality control. Ceramic coatings may provide even greater corrosion resistance for waste package and drip shield applications, although the boron-containing amorphous metals are still favored for criticality control applications. These amorphous metal and ceramic materials have been produced as gas-atomized powders and applied as near full density, nonporous coatings with the high-velocity oxy-fuel process. This article summarizes the performance of these coatings as corrosion-resistant barriers and as neutron absorbers. This article also presents a simple cost model to quantify the economic benefits possible with these new materials.

  1. Development and investigation of a pollution control pit for treatment of stormwater from metal roofs and traffic areas.

    Science.gov (United States)

    Dierkes, C; Göbel, P; Lohmann, M; Coldewey, W G

    2006-01-01

    Source control by on-site retention and infiltration of stormwater is a sustainable and proven alternative to classical drainage methods. Unfortunately, sedimentary particles and pollutants from drained surfaces cause clogging and endanger soil and groundwater during long-term operation of infiltration devices. German water authorities recommend the use of infiltration devices, such as swales or swale-trench-systems. Direct infiltration by underground facilities, such as pipes, trenches or sinks, without pretreatment of runoff is generally not permitted. Problems occur with runoff from metal roofs, traffic areas and industrial sites. However, due to site limitations, underground systems are often the only feasible option. To overcome this situation, a pollution control pit was developed with a hydrodynamic separator and a multistage filter made of coated porous concrete. The system treats runoff at source and protects soil, groundwater and receiving waterways. Typically, more than 90% of the pollutants such as sedimentary particles, hydrocarbons and heavy metals can be removed. Filters have been developed to treat even higher polluted stormwater loads from metal roofs and industrial sites. The treatment process is based on sedimentation, filtration, adsorption and chemical precipitation. Sediments are trapped in a special chamber within the pit and can be removed easily. Other pollutants are captured in the concrete filter upstream of the sediment separator chamber. Filters can be easily replaced.

  2. IDENTIFYING ROOF FALL PREDICTORS USING FUZZY CLASSIFICATION

    International Nuclear Information System (INIS)

    Bertoncini, C. A.; Hinders, M. K.

    2010-01-01

    Microseismic monitoring involves placing geophones on the rock surfaces of a mine to record seismic activity. Classification of microseismic mine data can be used to predict seismic events in a mine to mitigate mining hazards, such as roof falls, where properly bolting and bracing the roof is often an insufficient method of preventing weak roofs from destabilizing. In this study, six months of recorded acoustic waveforms from microseismic monitoring in a Pennsylvania limestone mine were analyzed using classification techniques to predict roof falls. Fuzzy classification using features selected for computational ease was applied on the mine data. Both large roof fall events could be predicted using a Roof Fall Index (RFI) metric calculated from the results of the fuzzy classification. RFI was successfully used to resolve the two significant roof fall events and predicted both events by at least 15 hours before visual signs of the roof falls were evident.

  3. 40 CFR 65.45 - External floating roof converted into an internal floating roof.

    Science.gov (United States)

    2010-07-01

    ... External floating roof converted into an internal floating roof. The owner or operator who elects to... 40 Protection of Environment 15 2010-07-01 2010-07-01 false External floating roof converted into an internal floating roof. 65.45 Section 65.45 Protection of Environment ENVIRONMENTAL PROTECTION...

  4. Green Roof Potential in Arab Cities

    OpenAIRE

    Attia, Shady

    2014-01-01

    Urban green roofs have long been promoted as an easy and effective strategy for beautifying the built environment and increasing investment opportunity. The building roof is very important because it has a direct impact on thermal comfort and energy conservation in and around buildings. Urban green roofs can help to address the lack of green space in many urban areas. Urban green roofs provides the city with open spaces that helps reduce urban heat island effect and provides the human populat...

  5. Use of endotrophic mycorhiza and soil microorganisms and vegetation establishment on mineral green roof substrate

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, J. [GeoVerde Inc., Schaffhausen (Switzerland)

    2004-07-01

    Green roofs have the potential to introduce colour and nature into urban and industrial areas. This paper showed how the addition of soil microorganisms into a green roof substrate can help establish vegetation. Microorganisms help the roots exploit essential nutrient and water reserves in the substrate by making them more readily available to the plant. Microorganisms facilitate uniform germination, plant development at the young stage, and prolonged vegetation development on the roof. Soil microorganisms and mycorrhizal fungi can be added directly in to the seed blends. As the products are blended with the seed, they also fulfill the function of a seeding aid. Mycorrhizal and other soil fungi were examined on mineral roof substrates by means of dry and hydroseeding in greenhouse and field tests. Results of this developmental work and experiences from practical applications were presented. It was noted that vegetation on green roof areas must be able to withstand harsh environmental conditions. As such, the challenges include drought that causes water stress, warm and cold temperatures, wind, acid rain and air pollution. This paper also presented details of the following categories of green roof systems. Intensive green roofs are usually referred to as roof gardens. They are constructed over reinforced concrete decks and usually are accessible. Simple intensive green roofs are vegetated with lawns or ground covering plants. Regular maintenance including irrigation, fertilization and mowing is also required. Extensive green roofs are low maintenance and low weight. Growing media is usually composed of purely mineral material or a blend of mineral with a low proportion of organic matter. Substrate is low in nutrient content and the depth . Vegetation usually consists of succulents that require minimal maintenance. The requirements to install each of these types of green roof systems were also presented. 7 refs., 3 tabs.

  6. GREEN ROOFS — A GROWING TREND

    Science.gov (United States)

    One of the most interesting stormwater control systems under evaluation by EPA are “green roofs”. Green roofs are vegetative covers applied to building roofs to slow, or totally absorb, rainfall runoff during storms. While the concept of over-planted roofs is very ancient, the go...

  7. Roofing Materials Assessment: Investigation of Five Metals in Runoff from Roofing Materials.

    Science.gov (United States)

    Winters, Nancy; Granuke, Kyle; McCall, Melissa

    2015-09-01

    To assess the contribution of five toxic metals from new roofing materials to stormwater, runoff was collected from 14 types of roofing materials and controls during 20 rain events and analyzed for metals. Many of the new roofing materials evaluated did not show elevated metals concentrations in the runoff. Runoff from several other roofing materials was significantly higher than the controls for arsenic, copper, and zinc. Notably, treated wood shakes released arsenic and copper, copper roofing released copper, PVC roofing released arsenic, and Zincalume® and EPDM roofing released zinc. For the runoff from some of the roofing materials, metals concentrations decreased significantly over an approximately one-year period of aging. Metals concentrations in runoff were demonstrated to depend on a number of factors, such as roofing materials, age of the materials, and climatic conditions. Thus, application of runoff concentrations from roofing materials to estimate basin-wide releases should be undertaken cautiously.

  8. Applications in the Nuclear Industry for Corrosion-Resistant Amorphous-Metal Thermal-Spray Coatings

    International Nuclear Information System (INIS)

    Farmer, J; Choi, J

    2007-01-01

    Amorphous metal and ceramic thermal spray coatings have been developed that can be used to enhance the corrosion resistance of containers for the transportation, aging and disposal of spent nuclear fuel and high-level radioactive wastes. Fe-based amorphous metal formulations with chromium, molybdenum and tungsten have shown the corrosion resistance believed to be necessary for such applications. Rare earth additions enable very low critical cooling rates to be achieved. The boron content of these materials, and their stability at high neutron doses, enable them to serve as high efficiency neutron absorbers for criticality control. Ceramic coatings may provide even greater corrosion resistance for container applications, though the boron-containing amorphous metals are still favored for criticality control applications. These amorphous metal and ceramic materials have been produced as gas atomized powders and applied as near full density, non-porous coatings with the high-velocity oxy-fuel process. This paper summarizes the performance of these coatings as corrosion-resistant barriers, and as neutron absorbers. Relevant corrosion models are also discussed, as well as a cost model to quantify the economic benefits possible with these new materials

  9. Characterization of laboratory and industrial CrN/CrCN/diamond-like carbon coatings

    Energy Technology Data Exchange (ETDEWEB)

    Silva, F.J.G., E-mail: francisco.silva@eu.ipp.pt [Departamento de Engenharia Mecânica do Instituto Superior de Engenharia do Porto do Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, 431, 4200-072 Porto (Portugal); Martinho, R.P. [Departamento de Engenharia da Escola Superior de Estudos Industriais e de Gestão do Instituto Politécnico do Porto, Rua D. Sancho I, 981, 4480-876 Vila do Conde (Portugal); Baptista, A.P.M. [Departamento de Engenharia Mecânica da Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto (Portugal)

    2014-01-01

    This work reports on laboratorial and experimental wear behaviour studies about a multi-layered film deposited by PVD (Physical Vapour Deposition) unbalanced magnetron sputtering. The film consists of three different layers: CrN in the bottom, CrCN as intermediate layer and DLC (diamond-like carbon) on the top. Film characterization was done using techniques such as Scanning Electron Microscopy, Energy Dispersive X-ray Spectroscopy, Atomic Force Microscopy and X-ray diffraction. Scratch-tests, nanoindentation analysis and ball-cratering wear tests were used in order to measure the adhesion critical load, hardness and wear coefficient, respectively. Experimental tests were developed letting one to realise the suitability of this film for mould cavities used on injection moulding machines that produce automotive parts in polypropylene reinforced with 30% (wt.) glass fibres, because this composite material performs severe abrasion on injection moulding which brings important challenges to surface wear resistance. Experimental tests revealed that, after 135,000 injection cycles, multi-layer coating improved significantly the performance previously revealed by uncoated samples. The good results achieved by this film can be partially assigned to DLC top layer due to its low friction coefficient. This paper discusses these results, comparing them with some other PVD coatings already tested in the same conditions. - Highlights: • This coating presents a very good adhesion to the P20 steel substrate. • Surface wear performance is largely improved by the use of this coating. • Coating wear resistance is about 58.2 times higher than the uncoated substrate. • This film presents high suitability for application in mould cavities.

  10. Wind Tunnel Tests for Wind Pressure Distribution on Gable Roof Buildings

    Science.gov (United States)

    2013-01-01

    Gable roof buildings are widely used in industrial buildings. Based on wind tunnel tests with rigid models, wind pressure distributions on gable roof buildings with different aspect ratios were measured simultaneously. Some characteristics of the measured wind pressure field on the surfaces of the models were analyzed, including mean wind pressure, fluctuating wind pressure, peak negative wind pressure, and characteristics of proper orthogonal decomposition results of the measured wind pressure field. The results show that extremely high local suctions often occur in the leading edges of longitudinal wall and windward roof, roof corner, and roof ridge which are the severe damaged locations under strong wind. The aspect ratio of building has a certain effect on the mean wind pressure coefficients, and the effect relates to wind attack angle. Compared with experimental results, the region division of roof corner and roof ridge from AIJ2004 is more reasonable than those from CECS102:2002 and MBMA2006.The contributions of the first several eigenvectors to the overall wind pressure distributions become much bigger. The investigation can offer some basic understanding for estimating wind load distribution on gable roof buildings and facilitate wind-resistant design of cladding components and their connections considering wind load path. PMID:24082851

  11. The effect of zinc bath temperature on the morphology, texture and corrosion behaviour of industrially produced hot-dip galvanized coatings

    Directory of Open Access Journals (Sweden)

    A. Bakhtiari

    2014-03-01

    Full Text Available The purpose of this work is to identify the influence of zinc bath temperature on the morphology, texture and corrosion behavior of hot-dip galvanized coatings. Hot-dip galvanized samples were prepared at temperature in the range of 450-480 °C in steps of 10 °C, which is the conventional galvanizing temperature range in the galvanizing industries. The morphology of coatings was examined with optical microscopy and scanning electron microscopy (SEM. The composition of the coating layers was determined using energy dispersive spectroscopy (EDS analysis. The texture of the coatings was evaluated using X-ray diffraction. Corrosion behavior was performed using salt spray cabinet test and Tafel extrapolation test. From the experimental results, it was found that increasing the zinc bath temperature affects the morphology of the galvanized coatings provoking the appearance of cracks in the coating structure. These cracks prevent formation of a compact structure. In addition, it was concluded that (00.2 basal plane texture component was weakened by increasing the zinc bath temperature and, conversely, appearance of (10.1 prism component, (20.1 high angle pyramidal component and low angle component prevailed. Besides, coatings with strong (00.2 texture component and weaker (20.1 components have better corrosion resistance than the coatings with weak (00.2 and strong (20.1 texture components. Furthermore, corrosion resistance of the galvanized coatings was decreased by increasing the zinc bath temperature.

  12. PREDICTING THERMAL PERFORMANCE OF ROOFING SYSTEMS IN SURABAYA

    Directory of Open Access Journals (Sweden)

    MINTOROGO Danny Santoso

    2015-07-01

    Full Text Available Traditional roofing systems in the developing country likes Indonesia are still be dominated by the 30o, 45o, and more pitched angle roofs; the roofing cover materials are widely used to traditional clay roof tiles, then modern concrete roof tiles, and ceramic roof tiles. In the 90’s decay, shop houses are prosperous built with flat concrete roofs dominant. Green roofs and roof ponds are almost rarely built to meet the sustainable environmental issues. Some tested various roof systems in Surabaya were carried out to observe the roof thermal performances. Mathematical equation model from three references are also performed in order to compare with the real project tested. Calculated with equation (Kabre et al., the 30o pitched concrete-roof-tile, 30o clay-roof-tile, 45o pitched concrete-roof-tile are the worst thermal heat flux coming to room respectively. In contrast, the bare soil concrete roof and roof pond system are the least heat flux streamed onto room. Based on predicted calculation without insulation and cross-ventilation attic space, the roof pond and bare soil concrete roof (greenery roof are the appropriate roof systems for the Surabaya’s climate; meanwhile the most un-recommended roof is pitched 30o or 45o angle with concrete-roof tiles roofing systems.

  13. Engineering and characterization of mesoporous silica-coated magnetic particles for mercury removal from industrial effluents

    International Nuclear Information System (INIS)

    Dong Jie; Xu Zhenghe; Wang Feng

    2008-01-01

    Mesoporous silica coatings were synthesized on dense liquid silica-coated magnetite particles using cetyl-trimethyl-ammonium chloride (CTAC) as molecular templates, followed by sol-gel process. A specific surface area of the synthesized particles as high as 150 m 2 /g was obtained. After functionalization with mercapto-propyl-trimethoxy-silane (MPTS) through silanation reaction, the particles exhibited high affinity of mercury in aqueous solutions. Atomic force microscopy (AFM), zeta potential measurement, thermal gravimetric analysis (TGA), analytical transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and atomic absorption spectroscopy (AAS) were used to characterize the synthesis processes, surface functionalization, and mercury adsorption on the synthesized magnetite particles. The loading capacity of the particles for mercury was determined to be as high as 14 mg/g at pH 2. A unique feature of strong magnetism of the synthesized nanocomposite particles makes the subsequent separation of the magnetic sorbents from complex multiphase suspensions convenient and effective

  14. Engineering and characterization of mesoporous silica-coated magnetic particles for mercury removal from industrial effluents

    Science.gov (United States)

    Dong, Jie; Xu, Zhenghe; Wang, Feng

    2008-03-01

    Mesoporous silica coatings were synthesized on dense liquid silica-coated magnetite particles using cetyl-trimethyl-ammonium chloride (CTAC) as molecular templates, followed by sol-gel process. A specific surface area of the synthesized particles as high as 150 m 2/g was obtained. After functionalization with mercapto-propyl-trimethoxy-silane (MPTS) through silanation reaction, the particles exhibited high affinity of mercury in aqueous solutions. Atomic force microscopy (AFM), zeta potential measurement, thermal gravimetric analysis (TGA), analytical transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and atomic absorption spectroscopy (AAS) were used to characterize the synthesis processes, surface functionalization, and mercury adsorption on the synthesized magnetite particles. The loading capacity of the particles for mercury was determined to be as high as 14 mg/g at pH 2. A unique feature of strong magnetism of the synthesized nanocomposite particles makes the subsequent separation of the magnetic sorbents from complex multiphase suspensions convenient and effective.

  15. Development of advanced metallic coatings resistant to corrosion in high temperature industrial atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Weber, T.; Bender, R.; Rosado, C.; Schuetze, M. [DECHEMA e.V., Frankfurt am Main (Germany)

    2004-07-01

    Following the experimental results that {gamma}-TiAl is highly resistant in reducing sulfidizing atmospheres the development of Ti-Al-co-diffusion coatings produced in a single step pack cementation process was started. The appropriate diffusion powder compositions were selected using thermodynamical calculations. Different Al-Ti-, Al-Si- and Al-Ti-Si-diffusion coatings were successfully applied on austenitic steels as well as Ni-base materials and showed excellent behaviour in reducing sulfidizing atmospheres with high carbon contents (CH{sub 4} - 1% CO - 1% CO{sub 2} - 10% H{sub 2} - 7% H{sub 2}S) up to 700 deg. C, under metal dusting conditions (H{sub 2} - 25 CO - 2% H{sub 2}O and CO - 2.4% CO{sub 2} - 1% CH{sub 4} - 9.4% N{sub 2} - 23.4% H{sub 2} - 0.2% H{sub 2}O - 1 ppm H{sub 2}S-0.3 ppm HCl) at temperatures of 620 deg. C and 700 deg. C. The application of diffusion coatings on ferritic materials has to be modified due to the specific requirements on the mechanical properties which are affected by the heat treatment during the diffusion process. TiAl was also applied by the HVOF thermal spray method on ferritic steels. Due to similarity of the thermal expansion coefficients this substrate-coating system proved to be mechanically very stable also under thermal cycling conditions. (authors)

  16. Investigation of the Degradation Mechanisms of Particulate Reinforced Epoxy Coatings and Zinc-Rich Coatings Under an Erosion and Corrosion Environment for Oil and Gas Industry Applications

    Science.gov (United States)

    Wang, Dailin

    During oil and gas production and transportation, the presence of an oil-sand slurry, together with the presence of CO2, H2S, oxygen, and seawater, create an erosive/abrasive and corrosive environment for the interior surfaces of undersea pipelines transporting oil and gas from offshore platforms. Erosion/wear and corrosion are often synergic processes leading to a much greater material loss of pipeline cross-section than that caused by each individual process alone. Both organic coatings and metallic sacrificial coatings have been widely employed to provide protection to the pipeline steels against corrosion through barrier protection and cathodic protection, and these protection mechanisms have been well studied. However, coating performance under the synergic processes of erosion/wear and corrosion have been much less researched and coating degradation mechanisms when erosion/wear and corrosion are both going on has not been well elucidated. In the work presented in this dissertation, steel panels coated with filler reinforced epoxy coatings and carbon nanotubes (CNTs) reinforced zinc-rich coatings have been evaluated under erosion/wear followed by an exposure to a corrosive environment. Electrochemical tests and material characterization methods have been applied to study the degradation mechanisms of the coatings during the tests and coating degradation mechanisms have been proposed. While organic coatings with a lower amount of filler particles provided better protection in a corrosive environment alone and in solid particle impingement erosion testing alone, organic coatings with a higher amount of filler particles showed better performance during wear testing alone. A higher amount of filler particles was also beneficial in providing protection against wear and corrosion environment, and erosion and corrosion environment. Coating thickness played a significant role in the barrier properties of the coatings under both erosion and corrosion tests. When the

  17. Orbital roof encephalocele mimicking a destructive neoplasm.

    Science.gov (United States)

    Alsuhaibani, Adel H; Hitchon, Patrick W; Smoker, Wendy R K; Lee, Andrew G; Nerad, Jeffrey A

    2011-01-01

    The purpose of this case report is to report an orbital roof encephalocele mimicking a destructive orbital neoplasm. Orbital roof encephalocele is uncommon but can mimic neoplasm. One potential mechanism for the orbital roof destruction is a post-traumatic "growing orbital roof fracture." The growing fracture has been reported mostly in children but can occur in adults. Alternative potential etiologies for the encephalocele are discussed, including Gorham syndrome. Orbital roof encephalocele is uncommon in adults, and the findings can superficially resemble an orbital neoplasm. Radiographic and clinical features that might suggest the correct diagnosis include a prior history of trauma, overlying frontal lobe encephalomalacia without significant mass effect or edema, and an orbital roof defect. The "growing fracture" mechanism may be a potential explanation for the orbital roof destruction in some cases.

  18. Generating realistic roofs over a rectilinear polygon

    KAUST Repository

    Ahn, Heekap

    2011-01-01

    Given a simple rectilinear polygon P in the xy-plane, a roof over P is a terrain over P whose faces are supported by planes through edges of P that make a dihedral angle π/4 with the xy-plane. In this paper, we introduce realistic roofs by imposing a few additional constraints. We investigate the geometric and combinatorial properties of realistic roofs, and show a connection with the straight skeleton of P. We show that the maximum possible number of distinct realistic roofs over P is ( ⌊(n-4)/4⌋ (n-4)/2) when P has n vertices. We present an algorithm that enumerates a combinatorial representation of each such roof in O(1) time per roof without repetition, after O(n 4) preprocessing time. We also present an O(n 5)-time algorithm for computing a realistic roof with minimum height or volume. © 2011 Springer-Verlag.

  19. Membrane-Based Technologies in the Pharmaceutical Industry and Continuous Production of Polymer-Coated Crystals/Particles.

    Science.gov (United States)

    Chen, Dengyue; Sirkar, Kamalesh K; Jin, Chi; Singh, Dhananjay; Pfeffer, Robert

    2017-01-01

    Membrane technologies are of increasing importance in a variety of separation and purification applications involving liquid phases and gaseous mixtures. Although the most widely used applications at this time are in water treatment including desalination, there are many applications in chemical, food, healthcare, paper and petrochemical industries. This brief review is concerned with existing and emerging applications of various membrane technologies in the pharmaceutical and biopharmaceutical industry. The goal of this review article is to identify important membrane processes and techniques which are being used or proposed to be used in the pharmaceutical and biopharmaceutical operations. How novel membrane processes can be useful for delivery of crystalline/particulate drugs is also of interest. Membrane separation technologies are extensively used in downstream processes for bio-pharmaceutical separation and purification operations via microfiltration, ultrafiltration and diafiltration. Also the new technique of membrane chromatography allows efficient purification of monoclonal antibodies. Membrane filtration techniques of reverse osmosis and nanofiltration are being combined with bioreactors and advanced oxidation processes to treat wastewaters from pharmaceutical plants. Nanofiltration with organic solvent-stable membranes can implement solvent exchange and catalyst recovery during organic solvent-based drug synthesis of pharmaceutical compounds/intermediates. Membranes in the form of hollow fibers can be conveniently used to implement crystallization of pharmaceutical compounds. The novel crystallization methods of solid hollow fiber cooling crystallizer (SHFCC) and porous hollow fiber anti-solvent crystallization (PHFAC) are being developed to provide efficient methods for continuous production of polymer-coated drug crystals in the area of drug delivery. This brief review provides a general introduction to various applications of membrane technologies in

  20. Bio deterioration behaviour in different colour roofing tiles (red and straw coloured); Comportamiento de tejas de diferente color (rojo y paja) frente al biodeterioro

    Energy Technology Data Exchange (ETDEWEB)

    Guzulla, M. F.; Sanchez, E.; Gonzalez, J. M.; Orduna, M.

    2014-07-01

    Bio colonization of building materials is a critical problem for the durability of constructions. Industrial experience shows that straw coloured roofing tiles are more prone to colonization than red roofing tiles, even having similar characteristics. The aim of this work is to explain the difference of bio colonization between different colour roofing tiles. The chemical composition of the surface of straw coloured and red roofing tiles, the phase composition and the microstructure of the roofing tiles were determined by WD-XRF, XRD and SEM-EDX, respectively. The pore size distribution was carried out by Hg porosimetry. The solubility was studied by determining the soluble salts (Ca, Mg, Na, K, Cl and SO{sub 4} 2-) by ICP-OES and ionic chromatography. Roofing tile bio receptivity was evaluated by determining fluorescence intensity using a pulse amplitude- modulated (PAM) fluoro meter, and cyanobacteria Oscillator sp. The results obtained show higher concentration of calcium and sulphur in straw coloured roofing tiles surface, and higher solubility than red roofing tiles. Moreover, according to the results obtained in bio receptivity assays, straw coloured roofing tiles are more prone to colonization than red roofing tiles, so, there is a relationship between surface properties of roofing tiles and bio colonization, as it is observed in industrial products. (Author)

  1. Sheffield's Green Roof Forum: a multi-stranded programme of green roof infrastructure development for the UK's greenest city

    Energy Technology Data Exchange (ETDEWEB)

    Dunnett, N. [Univ. of Sheffield, Western Bank, Sheffield (United Kingdom). Dept. of Landscape

    2006-07-01

    Sheffield, United Kingdom (UK) was the world centre for the steel and cutlery industries. However, those industries have been in decline and the city has been in the process of re-inventing itself over the past 20 years. Sheffield is now known as the UK's greenest city in terms of the amount of woodland, parkland and open spaces within its city limits. The city of Sheffield has also developed a unique partnership approach to promote green roof infrastructure as the most visible and high-profile signal of intent and symbol of low environmental impact building design and construction. This partnership involves Sheffield's Green Roof Forum, comprising the University of Sheffield's multi-disciplinary centre of excellence in green roof research; Sheffield City Council; Groundwork Sheffield, an urban economic and environmental regeneration agency; and city Architects and developers. This partnership meets six times a year to raise the profile of green roofs within the city and region, and to develop strategies to increase the uptake and implementation of green roof infrastructure in the region. This paper discussed the partnership, the Green Room Forum, accomplishments to date in promoting green roofs in the city, and the strategy for the Sheffield region to become a leader in green roof implementation and associated green technologies. The strategy is presented in two parts: consultation and research to identify the nature of market failure and devising methods to overcome that failure. The green roof strategy is being implemented through a program entitled Building Greener, Building Smarter and consists of four inter-linked strands. These strands were discussed in detail and included getting buy-in, demonstrating benefit, establishing the business case, and changing plans and practices. 3 tabs., 1 ref.

  2. Polyurethane adhesives in flat roofs

    OpenAIRE

    Bogárová Markéta; Stodůlka Jindřich; Šuhajda Karel

    2017-01-01

    It is necessary to stabilize individual layers of flat roofs, mainly because of wind suction. Apart from anchoring and surcharge, these layers can be secured by bonding. At present gluing is an indispensable and widely used stabilization method. On our market we can found many types of adhesives, most widely used are based on polyurethane. This paper focuses on problematic about stabilization thermal insulation from expanded polystyrene to vapor barrier from bitumen. One of the main issues is...

  3. Telescopic mine roof-support

    Energy Technology Data Exchange (ETDEWEB)

    Piscitelli, A

    1989-05-17

    A mining roof support which includes a main body consisting of a pair of telescopically associated elongated members and which slide relative to each other to extend the support, engaging one of the members. A locking plate which is movable into engagement with the member by means of a lever operated cam causes tilting of the plate to engage the member and then to raise the member and lock it in the raised position. 1 fig.

  4. Measured Energy Savings from the Application of Reflective Roofs in 3 AT and T Regeneration Buildings; FINAL

    International Nuclear Information System (INIS)

    Akbari, Hashen; Rainer, Leo

    2000-01-01

    Energy use and environmental parameters were monitored in three AT and T regeneration buildings during the summer of 2000. These buildings are constructed with concrete and are about 14.9 m2 (160 f2; 10x16 ft)in size. The buildings were initially monitored for about 1 1/2 months to establish a base condition. Then, the roofs of the buildings were painted with a white coating and the monitoring was continued. The original roof reflectances were about 26 percent; after the application of roof coatings the reflectivities increased to about 72 percent. In two of these buildings, we monitored savings of about 0.5kWh per day (8.6 kWh/m2[0.8 kWh/ft2]). The third building showed a reduction in air-conditioning energy use of about 13kWh per day. These savings probably resulted from the differences in the performance (EER) of the two dissimilar AC units in this building. The estimated annual savings for two of the buildings are about 125kWh per year; at a cost of dollar 0.1/kWh, savings are about dollar 12.5 per year. Obviously, it costs significantly more than this amount to coat the roofs with reflective coating, particularly because of the remote location of the buildings. However, since the prefabricated roofs are already painted green at the factory, painting them with white (reflective) color would bring no additional cost. Hence the payback time for having reflective roofs is nil, and the reflective roofs save an accumulated 370kWh over 30 years of the life of the roof

  5. Polyurethane adhesives in flat roofs

    Directory of Open Access Journals (Sweden)

    Bogárová Markéta

    2017-01-01

    Full Text Available It is necessary to stabilize individual layers of flat roofs, mainly because of wind suction. Apart from anchoring and surcharge, these layers can be secured by bonding. At present gluing is an indispensable and widely used stabilization method. On our market we can found many types of adhesives, most widely used are based on polyurethane. This paper focuses on problematic about stabilization thermal insulation from expanded polystyrene to vapor barrier from bitumen. One of the main issues is to calculate the exact amount of adhesive, which is required to guarantee the resistance against wind suction. In this problematic we can not find help neither in technical data sheets provided by the manufactures. Some of these data sheets contain at least information about amount of adhesive depending on location in roof plane and building height, but they do not specify the strength of such connection. It was therefore resorted to select several representatives polyurethane adhesives and their subsequent testing on specimens simulating the flat roof segment. The paper described the test methodology and results for two types of polyurethane adhesives.

  6. National construction, Denmark. Flat roofs

    Energy Technology Data Exchange (ETDEWEB)

    Rode, C

    1995-04-01

    The Paris meeting of IEA Annex 24 (held in the spring of 1991) declared a set of typical building constructions, the Heat, Air and Moisture characteristics of which should be dealt with as part of the Annex work. Each type of construction was assigned to one or more countries as their National Construction, and it has been the responsibility of each country to prepare a report on what may be regarded as common knowledge in the country on the hygrothermal behaviour of their construction. This knowledge is in part due to experimental work carried out by research bodies in the countries, and due to experience form practice. This report has two main sections: Section 2 gives a general overview of the design of the most common variants of flat roofs and common knowledge reported for such roofs. Section 3 gives an account of research projects carried out in Denmark on flat roofs to analyze their hygrothermal performance. Whenever possible, an emphasis will be put on the hygrothermal consequences of thermally insulating such constructions. (EG) 19 refs.

  7. Factors Influencing Arthropod Diversity on Green Roofs

    Directory of Open Access Journals (Sweden)

    Bracha Y. Schindler

    2011-01-01

    Full Text Available Green roofs have potential for providing substantial habitat to plants, birds, and arthropod species that are not well supported by other urban habitats. Whereas the plants on a typical green roof are chosen and planted by people, the arthropods that colonize it can serve as an indicator of the ability of this novel habitat to support a diverse community of organisms. The goal of this observational study was to determine which physical characteristics of a roof or characteristics of its vegetation correlate with arthropod diversity on the roof. We intensively sampled the number of insect families on one roof with pitfall traps and also measured the soil arthropod species richness on six green roofs in the Boston, MA area. We found that the number of arthropod species in soil, and arthropod families in pitfall traps, was positively correlated with living vegetation cover. The number of arthropod species was not significantly correlated with plant diversity, green roof size, distance from the ground, or distance to the nearest vegetated habitat from the roof. Our results suggest that vegetation cover may be more important than vegetation diversity for roof arthropod diversity, at least for the first few years after establishment. Additionally, we found that even green roofs that are small and isolated can support a community of arthropods that include important functional groups of the soil food web.

  8. Advanced knowledge system for coatings and the gas turbine MRO industry

    Energy Technology Data Exchange (ETDEWEB)

    Chandler, P.E.; Hall, W.; Shadbolt, N.R.; Alani, H.; Szomszo, M. [Southampton Univ. (United Kingdom)

    2008-07-01

    The growth of data generated within thermal spraying is, for many, a daunting business. Yet, this growing resource represents a largely untapped and potentially valuable asset capable of providing 'knowledge' rather than just 'information'. Many companies already use a range of Web based tools. However, the Web itself is changing and the vision for the future, the 'Semantic Web', is set to revolutionise how business will be done. One important aspect of this Web 'future' is that web pages will be greatly enriched and data will have additional information (tags) which help to describe it and more significantly, put the data into a context. This will enable machine readability and the use of query languages to ask direct questions. Following on from ideas introduced at ITSC 2007, a proof of concept demonstrator has been built for thermal spray coatings used in the Maintenance Repair and Overhaul (MRO) of gas turbines. A system has been built which stores and manipulates a range of data including; aircraft deliveries, RSS feeds of aircraft sales, engine types, MRO business details, thermal spray coatings and market dynamics. This paper presents the development of this system and discusses its future potential. (orig.)

  9. Performance Evaluation of Advanced Retrofit Roof Technologies Using Field-Test Data Phase Three Final Report, Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    Biswas, Kaushik [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    This article presents some miscellaneous data from two low-slope and two steep-slope experimental roofs. The low-slope roofs were designed to compare the performance of various roof coatings exposed to natural weatherization. The steep-slope roofs contained different combinations of phase change material, rigid insulation, low emittance surface and above-sheathing ventilation, with standing-seam metal panels on top. The steep-slope roofs were constructed on a series of adjacent attics separated at the gables using thick foam insulation. This article describes phase three (3) of a study that began in 2009 to evaluate the energy benefits of a sustainable re-roofing technology utilizing standing-seam metal roofing panels combined with energy efficient features like above-sheathing-ventilation (ASV), phase change material (PCM) and rigid insulation board. The data from phases 1 and 2 have been previously published and reported [Kosny et al., 2011; Biswas et al., 2011; Biswas and Childs, 2012; Kosny et al., 2012]. Based on previous data analyses and discussions within the research group, additional test roofs were installed in May 2012, to test new configurations and further investigate different components of the dynamic insulation systems. Some experimental data from phase 3 testing from May 2012 to December 2013 and some EnergyPlus modeling results have been reported in volumes 1 and 3, respectively, of the final report [Biswas et al., 2014; Biswas and Bhandari, 2014].

  10. Development of Radiation Processed Nano-Composite Blends and Nano-Coatings for Industrial Applications

    International Nuclear Information System (INIS)

    Dubey, K.A.; Kumar, Virendra; Bhardwaj, Yatender; Chaudhari, Chandrasekhar; Sarma, K.S.S.; Khader, Sheikh Abdul; Acharya, Satyanarayan

    2011-01-01

    Radiation processing of nanoparticle-filled polymer blends and coatings is expected to synergize the benefits of radiation processing and the flexibility of achieving various property combinations. High energy radiation can be utilized in a variety of ways to modify these systems. It can be used to crosslink the matrix, to compatibilize the blend components, to synthesize graft copolymer based compatibilizers, to improve interfacial bonding between the nanofiller/polymers or to freeze the morphology. Properties like flame retardency, permeability, abrasion resistance, biocompatibility and antibacterial activity can also be significantly affected by this composite approach. Due to the variety and quality of the product it promises, radiation processing of these mixed systems has been our core interest in the last few years. In the report, some of results on the radiation processing of SBR/EPDM blends and SBR/EPDM/MWNT nanocomposites are presented. (author)

  11. Development of Radiation Processed Nano-Composite Blends and Nano-Coatings for Industrial Applications

    Energy Technology Data Exchange (ETDEWEB)

    Dubey, K. A.; Kumar, Virendra; Bhardwaj, Yatender; Chaudhari, Chandrasekhar; Sarma, K. S.S.; Khader, Sheikh Abdul; Acharya, Satyanarayan [Bhabha Atomic Research Centre, Trombay, Mumbai (India)

    2011-07-01

    Radiation processing of nanoparticle-filled polymer blends and coatings is expected to synergize the benefits of radiation processing and the flexibility of achieving various property combinations. High energy radiation can be utilized in a variety of ways to modify these systems. It can be used to crosslink the matrix, to compatibilize the blend components, to synthesize graft copolymer based compatibilizers, to improve interfacial bonding between the nanofiller/polymers or to freeze the morphology. Properties like flame retardency, permeability, abrasion resistance, biocompatibility and antibacterial activity can also be significantly affected by this composite approach. Due to the variety and quality of the product it promises, radiation processing of these mixed systems has been our core interest in the last few years. In the report, some of results on the radiation processing of SBR/EPDM blends and SBR/EPDM/MWNT nanocomposites are presented. (author)

  12. Sustainability of thermoplastic vinyl roofing membrane systems

    Energy Technology Data Exchange (ETDEWEB)

    Graveline, S. P. [Sika Sanarfil, Canton, (United States)

    2010-07-01

    The International Council for Research and Innovation in Building and Construction (CIB-RILEM) has developed a framework for sustainable roofing based on a series of tenets divided into three key areas: preservation of the environment, conservation of energy, and extended roof life. This paper investigated the sustainability of thermoplastic vinyl roof membranes using these guidelines and the relevant tenets for roof system selection. Several tenets provided alternatives for minimizing the burden on the environment using non-renewable raw materials, conserving energy with thermal insulation, and extending the lifespan of all roof components by using long lasting membranes. A life cycle assessment was carried out to provide a quantitative framework for assessing the sustainability of roofing materials. It was found that the PVC membrane systems had a lesser impact on the environment than other competing systems.

  13. A Roof for the Lions' House

    Science.gov (United States)

    1978-01-01

    Fans of the National Football League s Detroit Lions don't worry about game day weather. Their magnificent new Pontiac Stadium has a domed, air-supported, fabric roof that admits light but protects the playing field and patrons from the elements. The 80,000-seat Silverdome is the world s largest fabric-covered structure-and aerospace technology played an important part in its construction. The key to economical construction of the Silverdome--and many other types of buildings--is a spinoff of fiber glass Beta yarn coated with Teflon TFE fluorocarbon resin. The big advance it offers is permanency.The team of DuPont, Chemical Fabrics and Birdair have collaborated on a number of fabric structures. Some are supported by air pressure, others by cables alone. Most of the structures are in the recreational category. With conventional construction costs still on the upswing, you're likely to see a great many more permanent facilities enclosed by the aerospace spinoff fabric.

  14. Extensive Green Roof Ecological Benefits in Latvia

    OpenAIRE

    Rušenieks, Rihards; Kamenders, Agris

    2013-01-01

    Extensive green roof ecological benefits are studiedin this paper. The research contains a brief explanation aboutgreen roof technology and green roof ecological benefits. Greenroof capability to retain rainwater runoff by accumulating it instorage layers and conducting it back into the atmospherethrough evapotranspiration is studied and modeled. Modeling isdone in Stormwater Management Model 5.0 software. The modelis based on an existing warehouse-type building located in Rigaand hourly Riga...

  15. The Geometric Theory of Roof Reflector Resonators

    Science.gov (United States)

    1976-12-01

    reflector, if properly oriented, (The terms "roof-top prism ," "right-angle prism ," and - incorrectly - " Porro prism " are encountered in .the literature...Q-switch prisms ) in laser resonators have been infrequent compared to the attention given spherical mirrors. This chapter summarizes the relevant...designator (Refs 42 and 43). In one experiment, a 900 roof prism was tested in a resonator with a 70% reflecting filat mirror. Thus, in Fig. 2, the right roof

  16. Key factors in successful green roof training

    International Nuclear Information System (INIS)

    Seeger, H.; Ansel, W.

    2004-01-01

    The green roof market in Germany has increased significantly in the past 3 decades, reaching a market share of 11 to 14 per cent. Three factors were responsible for the success of the green roof movement in Germany, namely the early introduction of quality standards and guidelines; the scientific investigation of ecological and economic benefits and the development of innovative and reliable technologies. In addition, seminars and workshops targeted at relevant groups encouraged green roof construction. Training courses and seminars proved to be efficient communication tools with the advantage of direct feedback from the participants to address sophisticated green roof problems and to integrate current ecological and economic frameworks. The content of the courses were tailored to the specific needs of the participants. In addition, organizers had considerable knowledge of green roof technology and related disciplines. The green roof guidelines in Germany are based on a range of scientific studies from universities, technical colleges and regional research institutions. These studies explored the technical performance of different green roof constructions and the ecological benefits for people and the environment. The market development in Germany is backed by the development of a wide range of innovative technologies which offer solutions for nearly all green roof issues, such as landscaping of sloped, barrel shaped roofs with low load bearing capacities. The German company ZinCo offers the international market a range of well tested and proven green roof systems for intensive and extensive roofs. Their flexible modular products can be adapted to the needs of different roof constructions and to locally specific climatic conditions. 6 refs., 1 fig

  17. A guidebook for insulated low-slope roof systems. IEA Annex 19, Low-slope roof systems: International Energy Agency Energy Conservation in Buildings and Community Systems Programme

    Energy Technology Data Exchange (ETDEWEB)

    1994-02-01

    Low-slope roof systems are common on commercial and industrial buildings and, to a lesser extent, on residential buildings. Although insulating materials have nearly always been a component of low-slope roofs, the amount of insulation used has increased in the past two decades because of escalation of heating and cooling costs and increased awareness of the need for energy conservation. As the amount of insulation has increased, the demand has intensified for design, installation, and maintenance information specifically for well-insulated roofs. Existing practices for design, installation, and maintenance of insulated roofs have evolved from experience. Typically, these practices feature compromises due to the different properties of materials making up a given roof system. Therefore, they should be examined from time to time to ensure that they are appropriate as new materials continue to enter the market and as the data base on existing systems expands. A primary purpose of this International Energy Agency (IEA) study is to assess current roofing insulation practices in the context of an accumulating data base on performance.

  18. Green roofs provide habitat for urban bats

    Directory of Open Access Journals (Sweden)

    K.L. Parkins

    2015-07-01

    Full Text Available Understanding bat use of human-altered habitat is critical for developing effective conservation plans for this ecologically important taxon. Green roofs, building rooftops covered in growing medium and vegetation, are increasingly important conservation tools that make use of underutilized space to provide breeding and foraging grounds for urban wildlife. Green roofs are especially important in highly urbanized areas such as New York City (NYC, which has more rooftops (34% than green space (13%. To date, no studies have examined the extent to which North American bats utilize urban green roofs. To investigate the role of green roofs in supporting urban bats, we monitored bat activity using ultrasonic recorders on four green and four conventional roofs located in highly developed areas of NYC, which were paired to control for location, height, and local variability in surrounding habitat and species diversity. We then identified bat vocalizations on these recordings to the species level. We documented the presence of five of nine possible bat species over both roof types: Lasiurus borealis, L. cinereus, L. noctivagans, P. subflavus,andE. fuscus. Of the bat calls that could be identified to the species level, 66% were from L. borealis. Overall levels of bat activity were higher over green roofs than over conventional roofs. This study provides evidence that, in addition to well documented ecosystem benefits, urban green roofs contribute to urban habitat availability for several North American bat species.

  19. Realistic roofs over a rectilinear polygon

    KAUST Repository

    Ahn, Heekap

    2013-11-01

    Given a simple rectilinear polygon P in the xy-plane, a roof over P is a terrain over P whose faces are supported by planes through edges of P that make a dihedral angle π/4 with the xy-plane. According to this definition, some roofs may have faces isolated from the boundary of P or even local minima, which are undesirable for several practical reasons. In this paper, we introduce realistic roofs by imposing a few additional constraints. We investigate the geometric and combinatorial properties of realistic roofs and show that the straight skeleton induces a realistic roof with maximum height and volume. We also show that the maximum possible number of distinct realistic roofs over P is ((n-4)(n-4)/4 /2⌋) when P has n vertices. We present an algorithm that enumerates a combinatorial representation of each such roof in O(1) time per roof without repetition, after O(n4) preprocessing time. We also present an O(n5)-time algorithm for computing a realistic roof with minimum height or volume. © 2013 Elsevier B.V.

  20. Membrane Distillation of Meat Industry Effluent with Hydrophilic Polyurethane Coated Polytetrafluoroethylene Membranes.

    Science.gov (United States)

    Mostafa, M G; Zhu, Bo; Cran, Marlene; Dow, Noel; Milne, Nicholas; Desai, Dilip; Duke, Mikel

    2017-09-29

    Meat rendering operations produce stick water waste which is rich in proteins, fats, and minerals. Membrane distillation (MD) may further recover water and valuable solids, but hydrophobic membranes are contaminated by the fats. Here, commercial hydrophobic polytetrafluorethylene (PTFE) membranes with a hydrophilic polyurethane surface layer (PU-PTFE) are used for the first time for direct contact MD (DCMD) on real poultry, fish, and bovine stick waters. Metal membrane microfiltration (MMF) was also used to capture fats prior to MD. Although the standard hydrophobic PTFE membranes failed rapidly, PU-PTFE membranes effectively processed all stick water samples to colourless permeate with sodium rejections >99%. Initial clean solution fluxes 5-6 L/m²/h declined to less than half during short 40% water recovery tests for all stick water samples. Fish stick water uniquely showed reduced fouling and up to 78% water recovery. Lost flux was easily restored by rinsing the membrane with clean water. MMF prior to MD removed 92% of fats, facilitating superior MD performance. Differences in fouling between stick waters were attributed to temperature polarisation from higher melt temperature fats and relative proportions to proteins. Hydrophilic coated MD membranes are applicable to stick water processing but further studies should consider membrane cleaning and longer-term stability.

  1. Membrane Distillation of Meat Industry Effluent with Hydrophilic Polyurethane Coated Polytetrafluoroethylene Membranes

    Directory of Open Access Journals (Sweden)

    M. G. Mostafa

    2017-09-01

    Full Text Available Meat rendering operations produce stick water waste which is rich in proteins, fats, and minerals. Membrane distillation (MD may further recover water and valuable solids, but hydrophobic membranes are contaminated by the fats. Here, commercial hydrophobic polytetrafluorethylene (PTFE membranes with a hydrophilic polyurethane surface layer (PU-PTFE are used for the first time for direct contact MD (DCMD on real poultry, fish, and bovine stick waters. Metal membrane microfiltration (MMF was also used to capture fats prior to MD. Although the standard hydrophobic PTFE membranes failed rapidly, PU-PTFE membranes effectively processed all stick water samples to colourless permeate with sodium rejections >99%. Initial clean solution fluxes 5–6 L/m2/h declined to less than half during short 40% water recovery tests for all stick water samples. Fish stick water uniquely showed reduced fouling and up to 78% water recovery. Lost flux was easily restored by rinsing the membrane with clean water. MMF prior to MD removed 92% of fats, facilitating superior MD performance. Differences in fouling between stick waters were attributed to temperature polarisation from higher melt temperature fats and relative proportions to proteins. Hydrophilic coated MD membranes are applicable to stick water processing but further studies should consider membrane cleaning and longer-term stability.

  2. Development Of An Improved Concrete Roman Tile Alternative Roofing System Using Waste Raw Materials Paper amp Saw Dust As Additives

    Directory of Open Access Journals (Sweden)

    Adegoke

    2015-05-01

    Full Text Available ABSTRACT Since the early civilizations in China Neolithic and the Middle East humans have recognized the dual desirable roles of clay tiles as roofing material which remain valid today - First it was an effective means to shed water from buildings and secondly it reduced the spread of fire. The Standard Double Roman tile SDRT was the first roof tile to be mass produced in South Africa. The Double Roman can trace its shape back to Roman engineering principles where it was discovered that arches have an ability to withstand greater pressures as the arch distributes the weight more evenly down to the base of the structure. However after the initial introduction of the concrete tile to Nigerian roofing market architects began to express displeasure with its unusually heavier weight than other competing roofing materials. Suggestions were made to original manufacturers for product improvement by reducing the overall product weight. Concrete tiles are composite materials made from mixture of Portland cement sharp sand smooth sand and natural fibre. Bolyn Industries 7 has established that a mix ratio by volume of 1cement112sharp sand112smooth sand with some fibre makes a good concrete tile product. The sharp sand provides strength while smooth sand provides smoothness to the concrete surface. This study seeks to improve the current Double Roman product by reducing its overall product weight which is currently at about 5.0 kg to about 4.0 kg. Going by the previous experience with Polycrete invention 2 it is hereby conceived that replacement of smooth sand with lighter waste materials such as paper or saw dust in the concrete tile constituents may achieve the desired product weight reduction. The study investigates the most economic mix ratio of the concrete tile constituents to achieve the desirable engineering properties of light weight strength durability water tightness and rust-proofness. Results with preliminary mix trials indicate that replacement

  3. Advanced ceramic coating development for industrial/utility gas turbines. Final report, 11 Mar 1979-1 Sep 1981

    International Nuclear Information System (INIS)

    Vogan, J.W.; Stetson, A.R.

    1982-01-01

    A program was conducted with the objective of developing advanced thermal barrier coating (TBC) systems. Coating application was by plasma spray. Duplex, triplex and graded coatings were tested. Coating systems incorporated both NiCrAly and CoCrAly bond coats. Four ceramic overlays were tested: ZrO 2 .82O 3 , CaO.TiO 2 , 2CaO.SiO 2 , and MgO.Al 2 O 3 . The best overall results were obtained with a CaO.TiO 2 coating applied to a NiCrAly bond coat. This coating was less sensitive than the ZrO 2 .8Y 2 O 3 coating to process variables and part geometry. Testing with fuels contaminated with compounds containing sulfur, phosphorus and alkali metals showed the zirconia coatings were destabilized. The calcium titanate coatings were not affected by these contaminants. However, when fuels were used containing 50 ppm of vanadium and 150 ppm of magnesium, heavy deposits were formed on the test specimens and combustor components that required frequent cleaning of the test rig. During the program Mars engine first-stage turbine blades were coated and installed for an engine cyclic endurance run with the zirconia, calcium titanate, and calcium silicate coatings. Heavy spalling developed with the calcium silicate system. The zirconia and calcium titanate systems survived the full test duration. It was concluded that these two TBC's showed potential for application in gas turbines

  4. Tribological performance evidence on ternary and quaternary nitride coatings applied for industrial steel

    Energy Technology Data Exchange (ETDEWEB)

    Caicedo, J. C.; Aguilar, Y. [Universidad del Valle, School of Materials Engineering, Ciudad Universitaria Melendez, Calle 13 No. 100-00, Edif. 320, A. A. 25360 Cali (Colombia); Aperador, W., E-mail: jcaicedoangulo1@gmail.com [Universidad Militar Nueva Granada, Department of Engineering, Carrera 11 No. 101-80, 6343200 Bogota D. C. (Colombia)

    2013-08-01

    A diagnostic of mechanical and tribological behavior in ternary Ti-C-N and quaternary Ti-Nb-C-N films deposited onto Si (100) and 4140 steel substrates by r.f. magnetron sputtering process varying negative bias voltage from 0 to 100 V, was done in this work. Growth parameters as power density, Ar/N{sub 2} flow rate, and substrate temperature were kept constant at the moment of the deposition. Introduction of Nb in the ternary Ti-C-N film was evaluated by X-ray diffraction analysis. Quantitative elemental concentration depth profile by glow discharge optical emission spectroscopy and the morphology via scanning electron microscopy were observed for the layers before the tests. Mechanical and tribological properties for both coatings were obtained by mean of nano indentation measurements through load versus displacement method, and scratch test using the critical load criterion, respectively. The failure modes from scratch test were observed via optical microscopy. X-ray diffraction results show as the amount of Nb is increased into the quaternary phase, the preferred orientation change in the film dur to the modification in the strain and lattice parameter. Energy dispersive X-ray results from previous work show the Ti CN and TiNbCN layers were stoichiometric. Nano indentation results reaching the elastic-plastic behavior of the Ti CN and Ti CN films with inclusion of Nb (TiNbCN), indicate not only the hardness and elastic modulus but also the critical load for the adhesive failure increase when increasing r.f negative bias voltage. An improvement of hardness and critical load around 60% and 28% for Ti CN as well as 26% and 31% for TiNbCN, respectively, was associated to an increasing in the r.f negative bias voltage from 0 to - 100 V. (Author)

  5. Sloshing impact in roofed tanks

    International Nuclear Information System (INIS)

    Uras, R.A.

    1995-01-01

    A large number of high-level waste (HLW) storage tanks exists in various tank farms. Seismic activities at those locations may cause significant sloshing in HLW tanks. These tanks are covered to avoid any spilling during large amplitude earthquakes. However, large amplitude sloshing may result in impact on the cover or the roof of the tank. Hence, a better understanding of the impact phenomenon is necessary to assess the safety of the tanks currently in existence, and to establish design guidelines for future designs. A pressure based formulation is derived to model sloshing impact in roofed tanks. It is incorporated into Argonne's in-house finite element code FLUSTR-ANL. A numerical test case with a harmonic input excitation is studied. The simulation results indicate that linear behavior is preserved beyond the first impact, and some mesh distortion is observed following a stronger second impact. During the impact, the displacement of the contacting surface nodes remains constant, and the velocities are reduced to zero. An identification of impacting nodes is possible from the dynamic pressures induced in surface elements

  6. Integrated roof wind energy system

    Directory of Open Access Journals (Sweden)

    Moonen S.P.G.

    2012-10-01

    Full Text Available Wind is an attractive renewable source of energy. Recent innovations in research and design have reduced to a few alternatives with limited impact on residential construction. Cost effective solutions have been found at larger scale, but storage and delivery of energy to the actual location it is used, remain a critical issue. The Integrated Roof Wind Energy System is designed to overcome the current issues of urban and larger scale renewable energy system. The system is built up by an axial array of skewed shaped funnels that make use of the Venturi Effect to accelerate the wind flow. This inventive use of shape and geometry leads to a converging air capturing inlet to create high wind mass flow and velocity toward a vertical-axis wind turbine in the top of the roof for generation of a relatively high amount of energy. The methods used in this overview of studies include an array of tools from analytical modelling, PIV wind tunnel testing, and CFD simulation studies. The results define the main design parameters for an efficient system, and show the potential for the generation of high amounts of renewable energy with a novel and effective system suited for the built environment.

  7. Wind loads on solar energy roofs

    NARCIS (Netherlands)

    Geurts, C.P.W.; Bentum, C.A. van

    2007-01-01

    This paper presents an overview of the wind loads on roofs, equipped with solar energy products, so called Active Roofs. Values given in this paper have been based on wind tunnel and full scale measurements, carried out at TNO, and on an interpretation of existing rules and guidelines. The results

  8. Do green roofs cool the air?

    NARCIS (Netherlands)

    Solcerova, A.; van de Ven, F.H.M.; Wang, Mengyu; Rijsdijk, Michiel; van de Giesen, N.C.

    2017-01-01

    Rapid urbanization and an increasing number and duration of heat waves poses a need to mitigate extremely high temperatures. One of the repeatedly suggested measures to moderate the so called urban heat island are green roofs. This study investigates several extensive sedum-covered green roofs in

  9. Flat roofs, a grey area; Grauzone Flachdach

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, Anja

    2012-11-01

    The boom of low-ballast assembly systems for flat roofs is going on. Solar assembly racks are set up directly on the sealing foil without fastening bolts. But what happens in case of water ingress? And what should be done to prevent damage to the roof cover? (orig.)

  10. Realistic roofs over a rectilinear polygon

    KAUST Repository

    Ahn, Heekap; Bae, Sangwon; Knauer, Christian; Lee, Mira; Shin, Chansu; Vigneron, Antoine E.

    2013-01-01

    Given a simple rectilinear polygon P in the xy-plane, a roof over P is a terrain over P whose faces are supported by planes through edges of P that make a dihedral angle π/4 with the xy-plane. According to this definition, some roofs may have faces

  11. Generating realistic roofs over a rectilinear polygon

    KAUST Repository

    Ahn, Heekap; Bae, Sangwon; Knauer, Christian; Lee, Mira; Shin, Chansu; Vigneron, Antoine E.

    2011-01-01

    Given a simple rectilinear polygon P in the xy-plane, a roof over P is a terrain over P whose faces are supported by planes through edges of P that make a dihedral angle π/4 with the xy-plane. In this paper, we introduce realistic roofs by imposing

  12. Turbostratic-like carbon nitride coatings deposited by industrial-scale direct current magnetron sputtering

    International Nuclear Information System (INIS)

    Louring, S.; Madsen, N.D.; Berthelsen, A.N.; Christensen, B.H.; Almtoft, K.P.; Nielsen, L.P.; Bøttiger, J.

    2013-01-01

    Carbon nitride thin films were deposited by direct current magnetron sputtering in an industrial-scale equipment at different deposition temperatures and substrate bias voltages. The films had N/(N + C) atomic fractions between 0.2 and 0.3 as determined by X-ray photoelectron spectroscopy (XPS). Raman spectroscopy provided insight into the ordering and extension of the graphite-like clusters, whereas nanoindentation revealed information on the mechanical properties of the films. The internal compressive film stress was evaluated from the substrate bending method. At low deposition temperatures the films were amorphous, whereas the film deposited at approximately 380 °C had a turbostratic-like structure as confirmed by high-resolution transmission electron microscopy images. The turbostratic-like film had a highly elastic response when subjected to nanoindentation. When a CrN interlayer was deposited between the film and the substrate, XPS and Raman spectroscopy indicated that the turbostratic-like structure was maintained. However, it was inconclusive whether the film still exhibited an extraordinary elastic recovery. An increased substrate bias voltage, without additional heating and without deposition of an interlayer, resulted in a structural ordering, although not to the extent of a turbostratic-like structure. - Highlights: • Carbon nitride films were deposited by industrial-scale magnetron sputtering. • The deposition temperature and the substrate bias voltage were varied. • A turbostratic-like structure was obtained at an elevated deposition temperature. • The turbostratic-like film exhibited a very high elastic recovery. • The influence of a CrN interlayer on the film properties was investigated

  13. Thermal performance of an innovative roof component

    Energy Technology Data Exchange (ETDEWEB)

    Dimoudi, A. [Department of Environmental Engineering, Democritus University of Thrace, Vassilisis Sofias 12, 67 100 Xanthi (Greece); Lykoudis, S. [Institute for Environmental Research and Sustainable Development, National Observatory of Athens, I. Metaxa and B. Pavlou, 152 36 Penteli (Greece); Androutsopoulos, A. [Buildings Department, Division of Energy Efficiency, Centre for Renewable Energy Sources (CRES), 19th km Marathonos Aven., 190 09 Pikermi (Greece)

    2006-11-15

    In this paper, the thermal performance of a ventilated roof component is investigated during the winter period. The ventilated roof component consists of a conventional roof structure - reinforced concrete with a layer of thermal insulation - an air gap that allows the movement of the ambient air and an external layer made of a prefabricated concrete slab. The experimental results of the ventilated roof component during the winter period are presented and its thermal performance is analysed. The effect of key construction parameters like the height of the air gap and the use of a radiant barrier in the air gap is also investigated. Analysis of the results showed that the performance of a ventilated roof component is comparable to a conventional structure during winter. The ventilated component is shown to be in compliance with Greek regulatory requirements in terms of U-value. (author)

  14. Thermal insulation performance of green roof systems

    Energy Technology Data Exchange (ETDEWEB)

    Celik, Serdar; Morgan, Susan; Retzlaff, William; Once, Orcun [southern Illinois University (United States)], e-mail: scelik@siue.edu, e-mail: smorgan@siue.edu, e-mail: wretzla@siue.edu, e-mail: oonce@siue.edu

    2011-07-01

    With the increasing costs of energy, good building insulation has become increasingly important. Among existing insulation techniques is the green roof system, which consists of covering the roof of a building envelop with plants. The aim of this paper is to assess the impact of vegetation type and growth media on the thermal performance of green roof systems. Twelve different green roof samples were made with 4 different growth media and 3 sedum types. Temperature at the sample base was recorded every 15 minutes for 3 years; the insulation behavior was then analysed. Results showed that the insulation characteristics were achieved with a combination of haydite and sedum sexangulare. This study demonstrated that the choice of growth media and vegetation is important to the green roof system's performance; further research is required to better understand the interactions between growth media and plant roots.

  15. Parametric study of roof diaphragm stiffness requirements

    International Nuclear Information System (INIS)

    Jones, W.D.; Tenbus, M.A.

    1991-01-01

    A common assumption made in performing a dynamic seismic analysis for a building is that the roof/floor system is open-quotes rigidclose quotes. This assumption would appear to be reasonable for many of the structures found in nuclear power plants, since many of these structures are constructed of heavily reinforced concrete having floor/roof slabs at least two feet in thickness, and meet the code requirements for structural detailing for seismic design. The roofs of many Department of Energy (DOE) buildings at the Oak Ridge Y-12 Plant in Oak Ridge, Tennessee, have roofs constructed of either metal, precast concrete or gypsum plank deck overlaid with rigid insulation, tar and gravel. In performing natural phenomena hazard assessments for one such facility, it was assumed that the existing roof performed first as a flexible diaphragm (zero stiffness) and then, rigid (infinitely stiff). For the flexible diaphragm model it was determined that the building began to experience significant damage around 0.09 g's. For the rigid diaphragm model it was determined that no significant damage was observed below 0.20 g's. A Conceptual Design Report has been prepared for upgrading/replacing the roof of this building. The question that needed to be answered here was, open-quotes How stiff should the new roof diaphragm be in order to satisfy the rigid diaphragm assumption and, yet, be cost effective?close quotes. This paper presents a parametric study of a very simple structural system to show that the design of roof diaphragms needs to consider both strength and stiffness (frequency) requirements. This paper shows how the stiffness of a roof system affects the seismically induced loads in the lateral, vertical load resisting elements of a building and provides guidance in determining how open-quotes rigidclose quotes a roof system should be in order to accomplish a cost effective design

  16. Cool roofs with high solar reflectance for the welfare of dairy farming animals

    Science.gov (United States)

    Santunione, G.; Libbra, A.; Muscio, A.

    2017-01-01

    Ensuring livestock welfare in dairy farming promotes the production capacity of the animals in terms of both quantity and quality. In welfare conditions, the animals can produce at their full potential. For the dairy cattle the most debilitating period of the year is summer, when the stress arising from overheating induces physiological alterations that compromise the animals’ productivity. In this study, the summer discomfort of dairy animals is primarily quantified and the production loss is quantified versus the Temperature Humidity Index (THI), which correlates the values of temperature and relative humidity to the thermal stress. In order to reduce or eliminate such thermal stress, it is then proposed to coat the roof of the stables with a paint having high solar reflectance and thermal emittance, that is a cool roof product. This type of roofing solution can considerably limit the overheating of stables caused by solar radiation, thus providing a positive impact on the animals’ welfare and improving significantly their productivity in summer.

  17. Green roof stormwater retention: effects of roof surface, slope, and media depth.

    Science.gov (United States)

    VanWoert, Nicholaus D; Rowe, D Bradley; Andresen, Jeffrey A; Rugh, Clayton L; Fernandez, R Thomas; Xiao, Lan

    2005-01-01

    Urban areas generate considerably more stormwater runoff than natural areas of the same size due to a greater percentage of impervious surfaces that impede water infiltration. Roof surfaces account for a large portion of this impervious cover. Establishing vegetation on rooftops, known as green roofs, is one method of recovering lost green space that can aid in mitigating stormwater runoff. Two studies were performed using several roof platforms to quantify the effects of various treatments on stormwater retention. The first study used three different roof surface treatments to quantify differences in stormwater retention of a standard commercial roof with gravel ballast, an extensive green roof system without vegetation, and a typical extensive green roof with vegetation. Overall, mean percent rainfall retention ranged from 48.7% (gravel) to 82.8% (vegetated). The second study tested the influence of roof slope (2 and 6.5%) and green roof media depth (2.5, 4.0, and 6.0 cm) on stormwater retention. For all combined rain events, platforms at 2% slope with a 4-cm media depth had the greatest mean retention, 87%, although the difference from the other treatments was minimal. The combination of reduced slope and deeper media clearly reduced the total quantity of runoff. For both studies, vegetated green roof systems not only reduced the amount of stormwater runoff, they also extended its duration over a period of time beyond the actual rain event.

  18. Evaluation of green roof as green technology for urban stormwater quantity and quality controls

    International Nuclear Information System (INIS)

    Kok, K H; Sidek, L M; Basri, H; Muda, Z C; Beddu, S; Abidin, M R Z

    2013-01-01

    Promoting green design, construction, reconstruction and operation of buildings has never been more critical than now due to the ever increasing greenhouse gas emissions and rapid urbanizations that are fuelling climate change more quickly. Driven by environmental needs, Green Building Index (GBI) was founded in Malaysia to drive initiative to lead the property industry towards becoming more environment-friendly. Green roof system is one of the assessment criteria of this rating system which is under category of sustainable site planning and management. An extensive green roof was constructed in Humid Tropics Center (HTC) Kuala Lumpur as one of the components for Stormwater Management Ecohydrology (SME) in order to obtain scientific data of the system. This paper evaluates the performance of extensive green roof at Humid Tropics Center with respect to urban heat island mitigation and stormwater quantity and quality controls. Findings indicate that there was a reduction of around 1.5°C for indoor temperature of the building after installation of green roof. Simulations showed that the peak discharge was reduced up to 24% relative to impervious brown roof. The results show an increment of pH and high concentration of phosphate for the runoff generated from the green roof and the runoff water quality ranged between class I and II under INWQS.

  19. Analysis of DOE s Roof Savings Calculator with Comparison to other Simulation Engines

    Energy Technology Data Exchange (ETDEWEB)

    New, Joshua Ryan [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Huang, Yu [White Box Technologies, Salt Lake City, UT (United States); Levinson, Ronnen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mellot, Joe [The Garland Company, Cleveland, OH (United States); Sanyal, Jibonananda [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Kenneth W [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-01-01

    A web-based Roof Savings Calculator (RSC) has been deployed for the Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs the latest web technologies and usability design to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned based on national averages and can provide estimated annual energy and cost savings after the user selects nothing more than building location. In addition to cool reflective roofs, the RSC tool can simulate multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance surfaces, HVAC duct location, duct leakage rates, multiple layers of building materials, ceiling and deck insulation levels, and other parameters. A base case and energy-efficient alternative can be compared side-by-side to generate an energy/cost savings estimate between two buildings. The RSC tool was benchmarked against field data for demonstration homes in Ft. Irwin, CA. However, RSC gives different energy savings estimates than previous cool roof simulation tools so more thorough software and empirical validation proved necessary. This report consolidates much of the preliminary analysis for comparison of RSC s projected energy savings to that from other simulation engines.

  20. Evaluation of green roof as green technology for urban stormwater quantity and quality controls

    Science.gov (United States)

    Kok, K. H.; Sidek, L. M.; Abidin, M. R. Z.; Basri, H.; Muda, Z. C.; Beddu, S.

    2013-06-01

    Promoting green design, construction, reconstruction and operation of buildings has never been more critical than now due to the ever increasing greenhouse gas emissions and rapid urbanizations that are fuelling climate change more quickly. Driven by environmental needs, Green Building Index (GBI) was founded in Malaysia to drive initiative to lead the property industry towards becoming more environment-friendly. Green roof system is one of the assessment criteria of this rating system which is under category of sustainable site planning and management. An extensive green roof was constructed in Humid Tropics Center (HTC) Kuala Lumpur as one of the components for Stormwater Management Ecohydrology (SME) in order to obtain scientific data of the system. This paper evaluates the performance of extensive green roof at Humid Tropics Center with respect to urban heat island mitigation and stormwater quantity and quality controls. Findings indicate that there was a reduction of around 1.5°C for indoor temperature of the building after installation of green roof. Simulations showed that the peak discharge was reduced up to 24% relative to impervious brown roof. The results show an increment of pH and high concentration of phosphate for the runoff generated from the green roof and the runoff water quality ranged between class I and II under INWQS.

  1. Run-off from roofing materials

    International Nuclear Information System (INIS)

    Roed, J.

    1985-01-01

    In order to find the runn-off from roof material, a roof has been constructed with two different slopes (30 deg. and 45 deg.). 7 Be and 137 Cs have been used as tracers. Considering new roof material, the pollution removed by run-off processes has been shown to be very different for various roof materials. The pollution is much more easily removed from silicon-treated material than from porous red-tile roof material. Cesium is removed more easily than beryllium. The content of cesium in old roof materials is greater in red-tile than in other less porous roof materials. However, the measured removal from new material does not correspond to the amount accumulated in the old. This could be explained by weathering and by saturation effects. The last effect is probably the more important. The measurements on old material indicate a removal of 44-86% of cesium pollution by run-off, whereas the measurement on new material showed a removal of only 31-50%. It has been demonstrated that the pollution concentration in run-off water could be very different from that in rainwater

  2. The use of aluminum dome tank roofs

    International Nuclear Information System (INIS)

    Morovich, G.L.

    1992-01-01

    Since the late 1970's the aluminum dome tank roof has gained wide usage for both new and retrofit applications. The increased application for the structure results from a need for maintenance reduction, environmental considerations, concern for product quality and economics. The American Petroleum Institute (API) has approved Standard API 650, Appendix G - Structurally Supported Aluminum Dome Roofs for publication. The aluminum dome was originally used as weather cover for retrofiting external floating roof tanks. The roof was considered for the reduction of maintenance related to draining water from the external floating roofs and problems resulting from freezing of drain lines and snow accumulation. This paper reports that environmental concerns have expanded the value of aluminum dome roofs. Rainwater bypassing the seals of an external floating roof became classified as a hazardous material requiring special and expensive disposal procedures. The marketing terminal facilities typically do not have the capacity for proper treatment of contaminated bottom water. With new fuel additives being water soluble, water contamination not only created a hazardous waste disposal problem, but resulted in reduced product quality

  3. Decision Guide for Roof Slope Selection

    Energy Technology Data Exchange (ETDEWEB)

    Sharp, T.R.

    1988-01-01

    This decision guide has been written for personnel who are responsible for the design, construction, and replacement of Air Force roofs. It provides the necessary information and analytical tools for making prudent and cost-effective decisions regarding the amount of slope to provide in various roofing situations. Because the expertise and experience of the decision makers will vary, the guide contains both basic slope-related concepts as well as more sophisticated technical data. This breadth of information enables the less experienced user to develop an understanding of roof slope issues before applying the more sophisticated analytical tools, while the experienced user can proceed directly to the technical sections. Although much of this guide is devoted to the analysis of costs, it is not a cost-estimating document. It does, however, provide the reader with the relative costs of a variety of roof slope options; and it shows how to determine the relative cost-effectiveness of different options. The selection of the proper roof slope coupled with good roof design, a quality installation, periodic inspection, and appropriate maintenance and repair will achieve the Air Force's objective of obtaining the best possible roofing value for its buildings.

  4. Characteristic roofing slates from Spain: Mormeau and Los Molinos

    Science.gov (United States)

    Cardenes Van den Eynde, Victor; Cnudde, Veerle; Cnudde, Jean Pierre

    2014-05-01

    Characteristic roofing slates from Spain: Mormeau and Los Molinos Cardenes1, V., Cnudde1, V., Cnudde1, J.P. 1 Department of Geology and Soil Science, Ghent University, Krijgslaan 281, S8, 9000 Ghent, Belgium. The world's major roofing slate outcrops are found in the NW of Spain, in the Ordovician terrains of the domain of the Truchas Syncline. In this remote area, slate was quarried since ancient times for the use of the inhabitants of the region. Half of a century ago, an industrialization process took place in this area, which began to produce high quality roofing slate for many buildings from Japan to the USA, and especially in Europe. Since then, Spanish slate roofing has been widely used for new buildings and also for restoration of historical buildings. This work revises the occurrence and characteristics of the two most representative grey slate varieties from the Truchas Syncline, Mormeau, a fine-grained slate, and Los Molinos, also a grey slate with a slightly coarser grain. Both slates have a very similar aspect, but Mormeau slate have some iron sulphides on its composition that sometimes forms oxidation spots. Mormeau beds are found at the Middle-Upper Ordovician age Casaio Formation, while Los Molinos beds are located at the Rozadais Formation, of age Upper Ordovician, defined as formation just for the Truchas Syncline domain. Both slates have a high degree of homogeneity on their constructive characteristics, with a typical composition of quartz, mica and chlorites, and a metamorphic degree corresponding to the green schists facies. This work revises the history and characteristics of both slates, that can be considered as lithotypes that can be used as a reference during the prospection of new slate outcrops worldwide. The presented varieties of slate are proposed for their inclusion as Global Heritage Stones.

  5. Parameter Studies on High-Velocity Oxy-Fuel Spraying of CoNiCrAlY Coatings Used in the Aeronautical Industry

    Directory of Open Access Journals (Sweden)

    J. A. Cabral-Miramontes

    2014-01-01

    Full Text Available The thermal spraying process is a surface treatment which does not adversely affect the base metal on which it is performed. The coatings obtained by HVOF thermal spray are employed in aeronautics, aerospace, and power generation industries. Alloys and coatings designed to resist oxidizing environments at high temperatures should be able to develop a surface oxide layer, which is thermodynamically stable, slowly growing, and adherent. MCrAlY type (M = Co, Ni or combination of both coatings are used in wear and corrosion applications but also provide protection against high temperature oxidation and corrosion attack in molten salts. In this investigation, CoNiCrAlY coatings were produced employing a HVOF DJH 2700 gun. The work presented here focuses on the influences of process parameters of a gas-drive HVOF system on the microstructure, adherence, wear, and oxygen content of CoNiCrAlY. The results showed that spray distance significantly affects the properties of CoNiCrAlY coatings.

  6. Impact- and earthquake- proof roof structure

    International Nuclear Information System (INIS)

    Shohara, Ryoichi.

    1990-01-01

    Building roofs are constituted with roof slabs, an earthquake proof layer at the upper surface thereof and an impact proof layer made of iron-reinforced concrete disposed further thereover. Since the roofs constitute an earthquake proof structure loading building dampers on the upper surface of the slabs by the concrete layer, seismic inputs of earthquakes to the buildings can be moderated and the impact-proof layer is formed, to ensure the safety to external conditions such as earthquakes or falling accidents of airplane in important facilities such as reactor buildings. (T.M.)

  7. Improving the durability of flat roof constructions

    DEFF Research Database (Denmark)

    Rudbeck, Claus Christian; Svendsen, Sv Aa Højgaard

    1999-01-01

    of the system, thereby making it easier to detect leaks faster. When a leak is detected, the membrane is repaired locally. In order to remove water which has already entered the insulation, an air gap or a system of air channels between the deck and the insulation is subjected to forced ventilation with outdoor...... air. When the water is removed, the ventilation is stopped, and the roofing construction can continue to function as intended.Roofing systems where trapped moisture can be removed are cost-effective compared to traditional roofing insulation systems, and as leakage can be treated, they have a longer...

  8. The Perception of Malaysian Architects towards the Implementation of Green Roofs: A Review of Practices, Methodologies and Future Research

    Directory of Open Access Journals (Sweden)

    Zahir M.H. Md.

    2014-01-01

    Full Text Available The implementation of green roofs or vegetated roof as a sustainable tool to mitigate the Urban Heat Island effect is relatively new in Malaysia. Although it has not been tested on an urban scale, many research findings have indicated that green roofs can contribute towards enhancing the environmental and aesthetical quality of the built environment. It was hypothesized that the low application of green roofs in the Malaysian construction industry is due to the lack of awareness, understanding and experience in its benefits especially among building practitioners. As a result, this research was initiated to determine the perception and understanding of Malaysian architects in green roofs implementation issues, as well as to identify their level of acceptance and readiness. This paper reviews practices and different research approaches in understanding the factors that influence architect’s perception towards the implementation of green roofs in the Malaysian construction industry. Architects were chosen as the only respondents due to their intensive involvement in the conceptualisation, planning, design and construction stage of a built environment project. Extensive literature review was conducted to explore past experiences in green roof implementation and to develop the theoretical framework for this research.

  9. 30 CFR 75.213 - Roof support removal.

    Science.gov (United States)

    2010-07-01

    ... mining experience shall perform permanent roof support removal work. (b) Prior to the removal of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Roof support removal. 75.213 Section 75.213... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Roof Support § 75.213 Roof support removal. (a)(1) All...

  10. 30 CFR 75.206 - Conventional roof support.

    Science.gov (United States)

    2010-07-01

    ... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Roof Support § 75.206 Conventional roof support. (a) Except in anthracite mines using non-mechanized mining systems, when conventional roof support... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Conventional roof support. 75.206 Section 75...

  11. Metal and nutrient dynamics on an aged intensive green roof.

    Science.gov (United States)

    Speak, A F; Rothwell, J J; Lindley, S J; Smith, C L

    2014-01-01

    Runoff and rainfall quality was compared between an aged intensive green roof and an adjacent conventional roof surface. Nutrient concentrations in the runoff were generally below Environmental Quality Standard (EQS) values and the green roof exhibited NO3(-) retention. Cu, Pb and Zn concentrations were in excess of EQS values for the protection of surface water. Green roof runoff was also significantly higher in Fe and Pb than on the bare roof and in rainfall. Input-output fluxes revealed the green roof to be a potential source of Pb. High concentrations of Pb within the green roof soil and bare roof dusts provide a potential source of Pb in runoff. The origin of the Pb is likely from historic urban atmospheric deposition. Aged green roofs may therefore act as a source of legacy metal pollution. This needs to be considered when constructing green roofs with the aim of improving pollution remediation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Roof instability characteristics and pre-grouting of the roof caving zone in residual coal mining

    Science.gov (United States)

    Zhao, Tong; Liu, Changyou

    2017-12-01

    Abandoned roadways and roof caving zones are commonly found in residual coal, and can destroy the integrity of the coal seam and roof. Resulting from mining-induced stress, continuous collapse and fracture instability in roof caving zones (RCZs) jeopardize the safety and efficiency of residual coal mining. Based on the engineering geology conditions of remining face 3101 in Shenghua Mine, the roof fracture and instability features of the RCZ were analyzed through physical simulation, theoretical analysis, and field measurements. In this case, influenced by the RCZ, the main roof across the RCZ fractured and rotated towards the goaf, greatly increasing the working resistance, and crushing the supports. The sudden instability of the coal pillars weakened its support of the main roof, thus resulting in long-key blocks across the RCZ and hinged roof structures, which significantly decreased the stability of the underlying immediate roof. This study establishes a mechanical model for the interactions between the surrounding rock and the supports in the RCZ, determines the reasonable working resistance, and examines the use of pre-grouting solidification restoration technology (PSRT) to solidify the RCZ and reinforce the coal pillars—thus increasing their bearing capacity. Field measurements revealed no roof flaking, inhomogeneous loading or support crushing, indicating that the PSRT effectively controlled the surrounding rock of the RCZ.

  13. How To Choose the Right Roofing System.

    Science.gov (United States)

    Carl, David

    2001-01-01

    Lists the factors that must be considered when specifying a roof for an existing or new facility. Factors discussed include cost, longevity, value of operations, warranties, building structure and design, and old vs. new system compatibility. (GR)

  14. Certified ecological roofs; Oekologisch mit Praedikat

    Energy Technology Data Exchange (ETDEWEB)

    Haslinger, Rupert

    2012-08-02

    Roofs of farm buildings are optimally suited for photovoltaic power supplies. Reimbursement for grid power supply is one interesting aspects, but electric power produced on site can also be used directly in agriculture and especially in viniculture.

  15. Influence of roof motion in LMFBR containment loading studies

    International Nuclear Information System (INIS)

    Potter, R.; Lancefield, M.J.; Sidoli, J.E.A.; Broadhouse, B.J.; Green, R.S.

    1982-01-01

    Following an HCDA the reactor roof may be threatened by coolant impact. Recent trends in CDFR roof design suggest that roof movement during the impact process may reduce the roof loading as a result of the fluid-structure interaction. The paper describes analytic studies of the phenomena, extensions to the SEURBNUK containment code to the roof flexibility and fluid-structure coupling, and results of experiments which confirm the reduced impulse and provide validation of the mathematical modelling

  16. Six aspects to inspirational green roof design

    Energy Technology Data Exchange (ETDEWEB)

    Kiers, H. [SWA Group, Sausalito, CA (United States)

    2004-07-01

    Green roofs have been categorized as a technology that is not initially faster, better or cheaper, and may even under perform established products. However, green roofs have features and values that early adopters are ready to experiment with in small markets, thereby creating awareness of the technology. Termed as disruptive technologies, green roofs can become competitive within the mainstream market against established products. The challenge in green roof construction is to find the correct balance between idealistic principles and leading edge design. This paper presented case studies to examine the following 6 aspects of design fundamentals to the creation of inspirational green roofs: the use of colour; experimentation with materials and technology; incorporation of texture, form, and pattern; definition of space; engagement of vistas; and, principles of bio-regionalism. It was concluded that good design is not enough to lead to widespread green roof implementation. It was emphasized that change will occur primarily because of the benefits acquired through implementation. 11 refs., 7 figs.

  17. Sloshing impact in roofed tanks

    International Nuclear Information System (INIS)

    Uras, R.A.

    1995-01-01

    A large number of high-level waste (HLW) storage tanks exists in various tank farms. Seismic activities at those locations may cause significant sloshing in HLW tanks. These tanks are covered to avoid any spilling during large amplitude earthquakes. However, large amplitude sloshing may result in impact on the cover or the roof of the tank. Hence, a better understanding of the impact phenomenon is necessary to assess the safety of the tanks currently in existence, and to establish design guidelines for future designs. A pressure based formulation is derived to model sloshing impact in roared tanks. It is incorporated into Argonne's in-house finite element code FLUSTR-ANL. A numerical test case with a harmonic input excitation is studied. The simulation results indicate that linear behavior is preserved beyond the first impact, and some mesh distortion is observed following a stronger second impact. During the impact, the displacement of the contacting surface nodes remains constant, and the velocities are reduced to zero. An identification of impacting nodes is possible from the dynamic pressures induced in surface elements

  18. The history and future of thermal sprayed galvanically active metallic anticorrosion coatings used on pipelines and steel structures in the oil and gas industry

    Energy Technology Data Exchange (ETDEWEB)

    Rodijnen, Fred van [Sulzer Metco, Duisburg (Germany)

    2008-07-01

    Since its invention by M. U. Schoop in the beginning of the 20th century, thermal spray has been used for corrosion protection applications in naval, on-shore, submerged and atmospheric environments. Thermally sprayed coatings of zinc, zinc alloys, aluminum and aluminum alloys are currently the most popular materials used for active corrosion protection of steel and concrete, which can be applied using either of the widely known thermal spray processes of combustion wire or electric arc wire. In the oil and gas exploration and production industry, corrosion protection applications using these technologies have evolved since the early sixties. Thermal spray technology has successfully been used to protect steel-based materials from corrosion in many different fields of application like platforms and pipelines. The most used material in the oil and gas industry is TSA (Thermally Sprayed Aluminum) coating. TSA coatings, with a lifetime of 25 to 30 years, require no maintenance except for cosmetic reasons when painted. The surface temperature of a TSA can go as high as 480 deg C. Although TS (Thermal Spray) is an older process, the number of applications and the number of m{sup 2} it is applied to is still increasing resulting from its maintenance-free and reliable active corrosion-protection features. (author)

  19. Recycling Roof Tile Waste Material for Wall Cover Tiles

    Directory of Open Access Journals (Sweden)

    Ambar Mulyono

    2014-02-01

    Full Text Available Prior research on roof tile waste treatment has attempted to find the appropriate technology to reuse old roof tile waste by  create  wall  cladding  materials  from  it.  Through  exploration  and  experimentation,  a  treatment  method  has  been discovered  to  transform  the  tile  fragments  into  artificial  stone  that  resembles  the  shape  of  coral.  This  baked  clay artificial stone material is then processed as a decorative element for vertical surfaces that are not load-bearing, such as on the interior and exterior walls of a building. Before applying the fragments as wall tiles, several steps must be taken: 1  Blunting,  which  changes  the  look  of  tile  fragments  using  a  machine  created  specifically  to  blunt  the  roof-tile fragment  edges,  2  Closing  the  pores  of  the  blunted  fragments  as  a  finishing  step  that  can  be  done  with  a  transparent coat or a solid color of paint, 3 Planting the transformed roof-tile fragments on a prepared tile body made of concrete. In this study, the second phase is done using the method of ceramics glazing at a temperature of 700 °C. The finishing step is the strength of this product because it produces a rich color artificial pebble.

  20. Cement blocks with EVA waste for extensive modular green roof: contribution of the components for thermal insulation

    Directory of Open Access Journals (Sweden)

    A. B. DE MELO

    Full Text Available Abstract Green roofs can contribute in many ways to the quality of the environment, being known for reducing the heat transfer to the interior of the buildings. Amongst the available techniques for the execution of this type of covering, the use of light cement blocks which are compatible with the system of extensive modular green roofs is proposed. For the light cement blocks, produced with EVA aggregates (waste from the footwear industry, an additional contribution in the capacity of thermal insulation of the proposed green roof is expected. In the present article, the demonstration of such contribution is intended through measurements carried out in prototypes in hot and humid climates. After characterizing the capacity of thermal insulation of the proposed green roof, with different types of conventional covering as a reference, an additional contribution of the component used in this green roof was identified by making comparisons with measurements collected from another green roof, executed with cement blocks without the presence of the EVA aggregates. In the experiments, external and internal surface temperatures were measured in each of the prototypes' coverings, as well as the air temperatures in the internal and external environments. From the analysis of the data for a typical summer day, it was possible to prove that the proposed green roof presented the lowest temperature ranges, considering the internal air and surface temperatures. The presence of the EVA aggregates in the proposed blocks contributed to the decrease of the internal temperatures.

  1. Industry

    International Nuclear Information System (INIS)

    Schindler, I.; Wiesenberger, H.

    2001-01-01

    This chapter of the environmental control report deals with the environmental impact of the industry in Austria. It gives a review of the structure and types of the industry, the legal framework and environmental policy of industrial relevance. The environmental situation of the industry in Austria is analyzed in detail, concerning air pollution (SO 2 , NO x , CO 2 , CO, CH 4 , N 2 O, NH 3 , Pb, Cd, Hg, dioxin, furans), waste water, waste management and deposit, energy and water consumption. The state of the art in respect of the IPPC-directives (European Integrated Pollution Prevention and Control Bureau) concerning the best available techniques of the different industry sectors is outlined. The application of European laws and regulations in the Austrian industry is described. (a.n.)

  2. Fuel consumption impacts of auto roof racks

    International Nuclear Information System (INIS)

    Chen, Yuche; Meier, Alan

    2016-01-01

    The after-market roof rack is one of the most common components attached to a vehicle for carrying over-sized items, such as bicycles and skis. It is important to understand these racks’ fuel consumption impacts on both individual vehicles and the national fleet because they are widely used. We estimate the national fuel consumption impacts of roof racks using a bottom-up approach. Our model incorporates real-world data and vehicle stock information to enable assessing fuel consumption impacts for several categories of vehicles, rack configurations, and usage conditions. In addition, the model draws on two new data-gathering techniques, on-line forums and crowd-sourcing. The results show that nationwide, roof racks are responsible for 0.8‰ of light duty vehicle fuel consumption in 2015, corresponding to 100 million gallons of gasoline per year. Sensitivity analyses show that results are most sensitive to the fraction of vehicles with installed roof racks but carrying no equipment. The aerodynamic efficiency of typical roof racks can be greatly improved and reduce individual vehicle fuel consumption; however, government policies to minimize extensive driving with empty racks—if successful—could save more fuel nationally. - Highlights: •First estimate of national energy impacts of auto roof racks—about 1‰. •A bottom-up approach reveals details of the fuel consumption penalty caused by racks. •Two novel data collection techniques, on-line forums and crowd-sourcing, improve estimate. •Technical and behavioral policies could significantly cut fuel penalties from roof racks.

  3. Research on the compressive strength of a passenger vehicle roof

    Science.gov (United States)

    Zhao, Guanglei; Cao, Jianxiao; Liu, Tao; Yang, Na; Zhao, Hongguang

    2017-05-01

    To study the compressive strength of a passenger vehicle roof, this paper makes the simulation test on the static collapse of the passenger vehicle roof and analyzes the stress and deformation of the vehicle roof under pressure in accordance with the Roof Crush Resistance of Passenger Cars (GB26134-2010). It studies the optimization on the major stressed parts, pillar A, pillar B and the rail of roof, during the static collapse process of passenger vehicle roof. The result shows that the thickness of pillar A and the roof rail has significant influence on the compressive strength of the roof while that of pillar B has minor influence on the compressive strength of the roof.

  4. Green roof valuation: a probabilistic economic analysis of environmental benefits.

    Science.gov (United States)

    Clark, Corrie; Adriaens, Peter; Talbot, F Brian

    2008-03-15

    Green (vegetated) roofs have gained global acceptance as a technologythat has the potential to help mitigate the multifaceted, complex environmental problems of urban centers. While policies that encourage green roofs exist atthe local and regional level, installation costs remain at a premium and deter investment in this technology. The objective of this paper is to quantitatively integrate the range of stormwater, energy, and air pollution benefits of green roofs into an economic model that captures the building-specific scale. Currently, green roofs are primarily valued on increased roof longevity, reduced stormwater runoff, and decreased building energy consumption. Proper valuation of these benefits can reduce the present value of a green roof if investors look beyond the upfront capital costs. Net present value (NPV) analysis comparing a conventional roof system to an extensive green roof system demonstrates that at the end of the green roof lifetime the NPV for the green roof is between 20.3 and 25.2% less than the NPV for the conventional roof over 40 years. The additional upfront investment is recovered at the time when a conventional roof would be replaced. Increasing evidence suggests that green roofs may play a significant role in urban air quality improvement For example, uptake of N0x is estimated to range from $1683 to $6383 per metric ton of NOx reduction. These benefits were included in this study, and results translate to an annual benefit of $895-3392 for a 2000 square meter vegetated roof. Improved air quality leads to a mean NPV for the green roof that is 24.5-40.2% less than the mean conventional roof NPV. Through innovative policies, the inclusion of air pollution mitigation and the reduction of municipal stormwater infrastructure costs in economic valuation of environmental benefits of green roofs can reduce the cost gap that currently hinders U.S. investment in green roof technology.

  5. Calculating the Insulated Car Roof Opening System Components and Strength Analysis of Car Design in Its Various Embodiments

    Directory of Open Access Journals (Sweden)

    V. S. Kopytov

    2016-01-01

    Full Text Available Opening roof cars can be used in transportation of a diversity of goods that require weather protection. Their operation allows us to fulfill the tasks of the Ministry of Railways that is to ensure both the qualitative and lossless transportation of various national economy and special loads and the significant improvement in the technical and economic indexes of the industry. Thus, there are three embodiment options of the opening roofs: single-leaf roof with axial of rotation along one car side; double-leaf roof with axial of rotation of its flaps along both car sides; single-leaf roof with axial of rotation along the car end wall. The work analyses and compares the first two options of the opening systems of the car roof. Analysis of various schemes of opening the roof-insulated cars is based on kinematic and force calculations. The paper defines how the changing length of hydraulic cylinders depends on the stroke and on the arm of applied force, depending on the opening roof angle for various embodiment options. To find the forces acting on the cylinders were determined the forces acting on the roof and the total applied moment of all the forces acting on them with respect to the axial of rotation. Thus, the total applied moment was considered to comprise the weighting unbalance moments of the roof and snow on it, as well as a moment of the force of wind acting on the roof (dead wind or downwind. Upon finding how the changing total moment of the force applied to the roof depends on the rotation angle and on the change of the applied force arm of hydraulic cylinders, the work determines the forces acting on the cylinders. The maximum tensile and compression force acting on the cylinders allows us to define their geometric characteristics such as piston stroke, diameter of the rod, piston-and rod-working cavity. Using a software package SADAS (developed at the Department "Rocket Launching Complexes" in BMSTU the core models were built and

  6. SOLAR RADIATION ESTIMATION ON BUILDING ROOFS AND WEB-BASED SOLAR CADASTRE

    Directory of Open Access Journals (Sweden)

    G. Agugiaro

    2012-07-01

    Full Text Available The aim of this study is the estimation of solar irradiance on building roofs in complex Alpine landscapes. Very high resolution geometric models of the building roofs are generated by means of advanced automated image matching methods. Models are combined with raster and vector data sources to estimate the incoming solar radiation hitting the roofs. The methodology takes into account for atmospheric effects, site latitude and elevation, slope and aspect of the terrain as well as the effects of shadows cast by surrounding buildings, chimneys, dormers, vegetation and terrain topography. An open source software solution has been developed and applied to a study area located in a mountainous site and containing some 1250 residential, commercial and industrial buildings. The method has been validated by data collected with a pyranometer and results made available through a prototype WebGIS platform.

  7. Comparative Assessment of Thermal Performance of Existing Roof System and Retrofitted Green Roof System in Istanbul, Turkey

    Directory of Open Access Journals (Sweden)

    Nil TÜRKERİ

    2011-01-01

    Full Text Available Urban heat islands, temperature increase due to climate change and energy consumption due to high summer cooling load are significant issues in Turkey. International studies indicate that the green roof system serves as an energy efficient building technology. However, the thermal performance of green roofs when exposed to local climate conditions is still unknown in Turkey. A research project is being conducted at Istanbul Technical University, in which part of a low-slope existing roof system was retrofitted as an extensive green roof system and the thermal performances of both the existing roof and green roof were monitored in order to make a comparative assessment. Both the green roof and the existing roof were instrumented to measure the temperature profile within the roof systems and the solar reflectance of the roof surfaces. Local meteorological variables were also measured. Results obtained from the field monitoring revealed the following data. Reflected solar radiation from the green roof surface was slightly higher than from the existing roof surface. This was likely to be due to the fact that the plants had not yet covered the entire soil surface area of the green roof. Plants reduced the amount of heat absorbed by the growing medium during daytime through shading and reduced the surface temperature of the green roof. Ceiling temperatures of rooms under the existing roof and green roof indicated that heat transfer to the room beneath the green roof was reduced as well. The green roof reduced the heat gain due to the thermal mass of the soil. This created a buffer against daily fluctuations in temperature and minimized temperature extremes.

  8. Fixing Trailer Hitch for Roof Rack of Cargos

    Directory of Open Access Journals (Sweden)

    Darina Matisková

    2017-02-01

    Full Text Available This article presents a new technical solution of fixing trailer hitch which serves as a connection between single track vehicle and cargo, mainly light trailer. They are manufactured from steel girder and nets which are constructed by point welding. They are designed to indicate the necessary solidity and the required load bearing capacity of the cargo. The application of roof racks is universal and these products are in great demand in the field of game management. There are a lot of trailer hitches which the manufacturers tailor to customers´ demands. The stated technical solution is subject of published industrial utility model at the Industrial property office of the Slovak republic.

  9. Metal and nutrient dynamics on an aged intensive green roof

    International Nuclear Information System (INIS)

    Speak, A.F.; Rothwell, J.J.; Lindley, S.J.; Smith, C.L.

    2014-01-01

    Runoff and rainfall quality was compared between an aged intensive green roof and an adjacent conventional roof surface. Nutrient concentrations in the runoff were generally below Environmental Quality Standard (EQS) values and the green roof exhibited NO 3 − retention. Cu, Pb and Zn concentrations were in excess of EQS values for the protection of surface water. Green roof runoff was also significantly higher in Fe and Pb than on the bare roof and in rainfall. Input–output fluxes revealed the green roof to be a potential source of Pb. High concentrations of Pb within the green roof soil and bare roof dusts provide a potential source of Pb in runoff. The origin of the Pb is likely from historic urban atmospheric deposition. Aged green roofs may therefore act as a source of legacy metal pollution. This needs to be considered when constructing green roofs with the aim of improving pollution remediation. -- Highlights: • Runoff from an aged intensive green roof was characterised. • Nutrient levels were not problematic for runoff quality. • High concentrations of Cu, Pb and Zn were found in the runoff. • Soil contamination was a likely source of metals in roof runoff. • Historic Pb atmospheric deposition may be the source of contamination. -- Aged green roofs may act as a store of legacy lead pollution

  10. Weathering of Roofing Materials-An Overview

    Energy Technology Data Exchange (ETDEWEB)

    Berdahl, Paul; Akbari, Hashem; Levinson, Ronnen; Miller, William A.

    2006-03-30

    An overview of several aspects of the weathering of roofing materials is presented. Degradation of materials initiated by ultraviolet radiation is discussed for plastics used in roofing, as well as wood and asphalt. Elevated temperatures accelerate many deleterious chemical reactions and hasten diffusion of material components. Effects of moisture include decay of wood, acceleration of corrosion of metals, staining of clay, and freeze-thaw damage. Soiling of roofing materials causes objectionable stains and reduces the solar reflectance of reflective materials. (Soiling of non-reflective materials can also increase solar reflectance.) Soiling can be attributed to biological growth (e.g., cyanobacteria, fungi, algae), deposits of organic and mineral particles, and to the accumulation of flyash, hydrocarbons and soot from combustion.

  11. Impact of Sustainable Cool Roof Technology on Building Energy Consumption

    Science.gov (United States)

    Vuppuluri, Prem Kiran

    Highly reflective roofing systems have been analyzed over several decades to evaluate their ability to meet sustainability goals, including reducing building energy consumption and mitigating the urban heat island. Studies have isolated and evaluated the effects of climate, surface reflectivity, and roof insulation on energy savings, thermal load mitigation and also ameliorating the urban heat island. Other sustainable roofing systems, like green-roofs and solar panels have been similarly evaluated. The motivation for the present study is twofold: the first goal is to present a method for simultaneous evaluation and inter-comparison of multiple roofing systems, and the second goal is to quantitatively evaluate the realized heating and cooling energy savings associated with a white roof system compared to the reduction in roof-top heat flux. To address the first research goal a field experiment was conducted at the International Harvester Building located in Portland, OR. Thermal data was collected for a white roof, vegetated roof, and a solar panel shaded vegetated roof, and the heat flux through these roofing systems was compared against a control patch of conventional dark roof membrane. The second research goal was accomplished using a building energy simulation program to determine the impact of roof area and roof insulation on the savings from a white roof, in both Portland and Phoenix. The ratio of cooling energy savings to roof heat flux reduction from replacing a dark roof with a white roof was 1:4 for the month of July, and 1:5 annually in Portland. The COP of the associated chillers ranges from 2.8-4.2, indicating that the ratio of cooling energy savings to heat flux reduction is not accounted for solely by the COP of the chillers. The results of the building simulation indicate that based on energy savings alone, white roofs are not an optimal choice for Portland. The benefits associated with cooling energy savings relative to a black roof are offset by

  12. Industrialization

    African Journals Online (AJOL)

    Lucy

    . African states as ... regarded as the most important ingredients that went to add value to land and labour in order for countries ... B. Sutcliffe Industry and Underdevelopment (Massachusetts Addison – Wesley Publishing Company. 1971), pp.

  13. Industrialization

    African Journals Online (AJOL)

    Lucy

    scholar, Walt W. Rostow presented and supported this line of thought in his analysis of ... A Brief Historical Background of Industrialization in Africa ... indicative) The western model allowed for the political economy to be shaped by market.

  14. Development of analytical procedures for the determination of hexavalent chromium in corrosion prevention coatings used in the automotive industry.

    Science.gov (United States)

    Séby, F; Castetbon, A; Ortega, R; Guimon, C; Niveau, F; Barrois-Oudin, N; Garraud, H; Donard, O F X

    2008-05-01

    The European directive 2000/53/EC limits the use of Cr(VI) in vehicle manufacturing. Although a maximum of 2 g of Cr(VI) was authorised per vehicle for corrosion prevention coatings of key components, since July 2007 its use has been prohibited except for some particular applications. Therefore, the objective of this work was to develop direct analytical procedures for Cr(VI) determination in the different steel coatings used for screws. Instead of working directly with screws, the optimisation of the procedures was carried out with metallic plates homogeneously coated to improve the data comparability. Extraction of Cr(VI) from the metallic parts was performed by sonication. Two extraction solutions were tested: a direct water extraction solution used in standard protocols and an ammonium/ammonia buffer solution at pH 8.9. The extracts were further analysed for Cr speciation by high-performance liquid chromatography (HPLC) inductively coupled plasma (ICP) atomic emission spectrometry or HPLC ICP mass spectrometry depending on the concentration level. When possible, the coatings were also directly analysed by solid speciation techniques (X-ray photoelectron spectroscopy, XPS, and X-ray absorption near-edge structure, XANES) for validation of the results. Very good results between the different analytical approaches were obtained for the sample of coating made up of a heated paint containing Zn, Al and Cr when using the extracting buffer solution at pH 8.9. After a repeated four-step extraction procedure on the same portion test, taking into account the depth of the surface layer reached, good agreement with XPS and XANES results was obtained. In contrast, for the coatings composed of an alkaline Zn layer where Cr(VI) and Cr(III) are deposited, only the extraction procedure using water allowed the detection of Cr(VI). To elucidate the Cr(VI) reduction during extraction at pH 8.9, the reactivity of Cr(VI) towards different species of Zn generally present in the

  15. Effects of roof and rainwater characteristics on copper concentrations in roof runoff.

    Science.gov (United States)

    Bielmyer, Gretchen K; Arnold, W Ray; Tomasso, Joseph R; Isely, Jeff J; Klaine, Stephen J

    2012-05-01

    Copper sheeting is a common roofing material used in many parts of the world. However, copper dissolved from roof sheeting represents a source of copper ions to watersheds. Researchers have studied and recently developed a simple and efficient model to predict copper runoff rates. Important input parameters include precipitation amount, rain pH, and roof angle. We hypothesized that the length of a roof also positively correlates with copper concentration (thus, runoff rates) on the basis that runoff concentrations should positively correlate with contact time between acidic rain and the copper sheet. In this study, a novel system was designed to test and model the effects of roof length (length of roof from crown to the drip edge) on runoff copper concentrations relative to rain pH and roof angle. The system consisted of a flat-bottom copper trough mounted on an apparatus that allowed run length and slope to be varied. Water of known chemistry was trickled down the trough at a constant rate and sampled at the bottom. Consistent with other studies, as pH of the synthetic rainwater decreased, runoff copper concentrations increased. At all pH values tested, these results indicated that run length was more important in explaining variability in copper concentrations than was the roof slope. The regression equation with log-transformed data (R(2) = 0.873) accounted for slightly more variability than the equation with untransformed data (R(2) = 0.834). In log-transformed data, roof angle was not significant in predicting copper concentrations.

  16. Green roofs as a means of pollution abatement

    International Nuclear Information System (INIS)

    Rowe, D. Bradley

    2011-01-01

    Green roofs involve growing vegetation on rooftops and are one tool that can help mitigate the negative effects of pollution. This review encompasses published research to date on how green roofs can help mitigate pollution, how green roof materials influence the magnitude of these benefits, and suggests future research directions. The discussion concentrates on how green roofs influence air pollution, carbon dioxide emissions, carbon sequestration, longevity of roofing membranes that result in fewer roofing materials in landfills, water quality of stormwater runoff, and noise pollution. Suggestions for future directions for research include plant selection, development of improved growing substrates, urban rooftop agriculture, water quality of runoff, supplemental irrigation, the use of grey water, air pollution, carbon sequestration, effects on human health, combining green roofs with complementary related technologies, and economics and policy issues. - Green roofs can help mitigate air pollution, carbon dioxide emissions, sequester carbon, conserve energy, reduce the urban heat island, and improve water quality.

  17. Study of radioactivity diffusion for bitumen-coated blocks produced by an industrial coating plant; Etude de la diffusion de la radioactivite de blocs d'enrobes bitumineux en provenance d'un atelier d'enrobage industriel

    Energy Technology Data Exchange (ETDEWEB)

    Rodier, J; Lefillatre, G [Commissariat a l' Energie Atomique, Chusclan (France). Centre de Production de Plutonium de Marcoule

    1969-07-01

    The solidification by bitumen of chemical coprecipitation sludges from the Marcoule waste treatment station has been studied in the laboratory and has led to the construction of an industrial coating plant. The quality of the coated material obtained has been controlled by the lixiviation test carried out with ordinary water and with sea-water on 45 ml laboratory samples and on industrial coated blocks of 150 litres. Tests on blocks of such a size have necessitated the installation of three special tanks. Two, each of 2000 litres capacity, contain ordinary and sea-water which was continuously recycled at a rate of 2.5 cm/hr and renewed periodically. In the third tank having a capacity of 11000 litres, the coated block was buried in earth and sprinkled with ordinary water with a view to studying the migration of radioelements in soil. The results of these tests confirm those obtained during the laboratory experiments. (authors) [French] La solidification par le bitume des boues de coprecipitation chimique de la station de traitement des effluents du Centre de Marcoule, etudiee en laboratoire, a conduit a la realisation d'une installation industrielle d'enrobage. La qualite de l'enrobe obtenu a ete controlee par le test de lixiviation qui a ete effectue en eau ordinaire et en eau de mer sur des echantillons de laboratoire de 45 ml et sur des blocs d'enrobe industriel de 150 litres. L'experimentation sur des blocs de telles dimensions a necessite l'installation de 3 cuves speciales. Deux, d'une capacite de 2000 litres, contiennent de l'eau ordinaire et de l'eau de mer recyclees en permanence a une vitesse de 2.5 cm/h et renouvelees periodiquement. Dans la 3eme cuve d'une capacite de 11000 litres, le bloc d'enrobe a ete enfoui dans de la terre et asperge d'eau ordinaire afin d'etudier la migration des radioelements dans le sol. Les resultats de ces essais confirment ceux obtenus au cours des tests de laboratoire. (auteurs)

  18. Industry

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, Lenny; Roy, Joyashree; Delhotal, K. Casey; Harnisch, Jochen; Matsuhashi, Ryuji; Price, Lynn; Tanaka, Kanako; Worrell, Ernst; Yamba, Francis; Fengqi, Zhou; de la Rue du Can, Stephane; Gielen, Dolf; Joosen, Suzanne; Konar, Manaswita; Matysek, Anna; Miner, Reid; Okazaki, Teruo; Sanders, Johan; Sheinbaum Parado, Claudia

    2007-12-01

    This chapter addresses past, ongoing, and short (to 2010) and medium-term (to 2030) future actions that can be taken to mitigate GHG emissions from the manufacturing and process industries. Globally, and in most countries, CO{sub 2} accounts for more than 90% of CO{sub 2}-eq GHG emissions from the industrial sector (Price et al., 2006; US EPA, 2006b). These CO{sub 2} emissions arise from three sources: (1) the use of fossil fuels for energy, either directly by industry for heat and power generation or indirectly in the generation of purchased electricity and steam; (2) non-energy uses of fossil fuels in chemical processing and metal smelting; and (3) non-fossil fuel sources, for example cement and lime manufacture. Industrial processes also emit other GHGs, e.g.: (1) Nitrous oxide (N{sub 2}O) is emitted as a byproduct of adipic acid, nitric acid and caprolactam production; (2) HFC-23 is emitted as a byproduct of HCFC-22 production, a refrigerant, and also used in fluoroplastics manufacture; (3) Perfluorocarbons (PFCs) are emitted as byproducts of aluminium smelting and in semiconductor manufacture; (4) Sulphur hexafluoride (SF{sub 6}) is emitted in the manufacture, use and, decommissioning of gas insulated electrical switchgear, during the production of flat screen panels and semiconductors, from magnesium die casting and other industrial applications; (5) Methane (CH{sub 4}) is emitted as a byproduct of some chemical processes; and (6) CH{sub 4} and N{sub 2}O can be emitted by food industry waste streams. Many GHG emission mitigation options have been developed for the industrial sector. They fall into three categories: operating procedures, sector-wide technologies and process-specific technologies. A sampling of these options is discussed in Sections 7.2-7.4. The short- and medium-term potential for and cost of all classes of options are discussed in Section 7.5, barriers to the application of these options are addressed in Section 7.6 and the implication of

  19. Probabilistic economic analysis of green roof benefits for policy design

    International Nuclear Information System (INIS)

    Clark, C.; Adriaens, P.; Talbot, B.

    2006-01-01

    The installation costs of green roofs continue to deter widespread use of green roof technology. Analyses of the boundary conditions for the cost differential between a green roof and a conventional roof are usually compared to environmental benefits such as storm water reduction and building energy savings. However, evidence is emerging that green roofs may play a role in urban air quality improvement. This paper discussed a methodology for developing probabilistic ranges of benefits and cost analyses. A probabilistic analysis was conducted to prepare a generalized cost-benefit analysis for application to a range of green roof projects. Environmental benefits of roof greening were quantified on a per unit surface area to assess environmental impact at the building scale. Parameters included conventional and green roof installation costs; storm water fees and fee reductions for green roofs; energy costs due to heat flux and the resultant savings through the installation of a green roof and the additional economic valuation of the public health benefits due to air pollution mitigation. Results were then integrated into an economic model to determine the length of time required for a return on investment in a green roof, assuming that a traditional roof would require replacement after 20 years. A net present value analysis was performed for an average-sized university roof. Results of the study showed that a valuation of environmental benefits can reduce the time required for a return on investment in a moderately priced green roof. While reduced installation costs reduced the time required for a return on investment, optimizing the green roof system for maximum environmental benefit had a greater potential to provide a higher return. It was concluded that the benefit of improved air quality should not be ignored by green roof policy-makers as a valuation tool. 10 refs., 3 tabs., 1 fig

  20. EVALUACIÓN DE UN RECUBRIMIENTO FORMULADO CON BASE EN PINTURA INDUSTRIAL Y EXTRACTO DE Aloe saponaria EXPUESTO A LA ATMÓSFERA MARINA I EVALUATION OF A COATING MADE FROM INDUSTRIAL PAINT BASE AND EXTRACT OF Aloe saponaria EXPOSED TO MARINE ATMOSPHERE

    OpenAIRE

    Asyuri del Valle Roquez Ramos; Solange Ysbeth Paredes Dugarte

    2018-01-01

    A base of industrial paint mixed with extract of plants of the genus Aloe was evaluated as a possible corrosion inhibiting coating. A phosphate buffered saline solution (BFS) was used to prepare the aqueous extract of Aloe saponaria and mixtures were prepared based industrial paint and the aqueous extract at different ratios (80:20, 70:30, 60:40, 50:50). Plates of AA3003 aluminum alloy were coated and exposed to the marine atmosphere using the Sucre Atmospher...

  1. Bamboo Fibre Reinforced Cement Used as a Roofing Sheet | Alade ...

    African Journals Online (AJOL)

    Bamboo fibre roofing sheet was able to withstand an average load of 51Kg, which is above the minimum required strength of 50kg. Comparatively, Asbestos roofing sheets and coconut fibre roofing sheets of similar dimensions had failure loads of 104.65Kg and 79Kg respectively. When immersed in water, bamboo fibre ...

  2. Green roofs : a resource manual for municipal policy makers

    Energy Technology Data Exchange (ETDEWEB)

    Lawlor, G.; Currie, B.A.; Doshi, H.; Wieditz, I. [Canada Mortgage and Housing Corp., Ottawa, ON (Canada)

    2006-05-15

    As knowledge of the environmental benefits of green roofs and technology improves, green roofs are quickly gaining acceptance in North America. European jurisdictions have been using green roof technology for stormwater management, to reduce energy use in buildings and to increase amenity space. By reviewing the reasons that municipalities throughout the world have set green roof policies and programs, policy makers can more easily determine which policies suit their needs. This manual provided an overview of international and Canadian green roof policies and programs. It presented information on 12 jurisdictions that demonstrated leadership in green roof policy development. The manual also presented information on an additional 13 jurisdictions with less-developed green roof policies. Activities that were discussed for each of these jurisdictions included: description of jurisdiction; key motivators; green roof policy; process to establish policy; effectiveness; lessons learned; future predictions; and applicability to Canada of international jurisdictions. The manual also provided general information on green roofs such as a definition of green roofs and green roof terminology. Key motivators for green roofs include stormwater runoff control; reduction in urban heat-island effect; reduction in building energy consumption; and air pollution control. refs., tabs., figs.

  3. The Development of a Roof Integrated Solar Hot Water System

    Energy Technology Data Exchange (ETDEWEB)

    Menicucci, David F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Energy Infrastructure and DER Dept.; Moss, Timothy A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Solar Technologies Dept.; Palomino, G. Ernest [Salt River Project (SRP), Tempe, AZ (United States)

    2006-09-01

    The Salt River Project (SRP), in conjunction with Sandia National Laboratories (SNL) and Energy Laboratories, Inc. (ELI), collaborated to develop, test, and evaluate an advanced solar water-heating product for new homes. SRP and SNL collaborated under a Department of Energy Cooperative Research and Development Agreement (CRADA), with ELI as SRP's industry partner. The project has resulted in the design and development of the Roof Integrated Thermal Siphon (RITH) system, an innovative product that features complete roof integration, a storage tank in the back of the collector and below the roofline, easy installation by homebuilders, and a low installed cost. SRP's market research guided the design, and the laboratory tests conducted at SNL provided information used to refine the design of field test units and indicated that the RITH concept is viable. ELI provided design and construction expertise and is currently configured to manufacture the units. This final report for the project provides all of the pertinent and available materials connected to the project including market research studies, the design features and development of the system, and the testing and evaluation conducted at SNL and at a model home test site in Phoenix, Arizona.

  4. Ruthenium recovery from acetic acid industrial effluent using chemically stable and high-performance polyethylenimine-coated polysulfone-Escherichia coli biomass composite fibers

    International Nuclear Information System (INIS)

    Kim, Sok; Choi, Yoon-E; Yun, Yeoung-Sang

    2016-01-01

    Highlights: • The PEI-PSBF was fabricated and used for Ru recovery from industrial effluent. • PEI-PSBF was not swollen nor dissolved in the effluent. • PEI-PSBF showed superior sorption capacity to commercial resins. • Thin fiber type PEI-PSBF could be successfully applied in flow-through column. - Abstract: Recovery of precious metal ions from waste effluents is of high concern. In general, ruthenium (Ru) is used in the Cativa process as promoter for carbonylation catalyst and discharged into acetic acid effluent. In the present work, we have designed and developed polyethylenimine-coated polysulfone-bacterial biomass composite fiber (PEI-PSBF) to recover Ru from industrial effluent. The sorbent was manufactured by electrostatic attachment of polyethylenimine (PEI) to the surface of polysulfone-biomass composite fiber (PSBF), which was prepared through spinning of the mixture of polysulfone and Escherichia coli biomass in N,N-dimethylformamide (DMF) into water. Developed PEI-PSBF was highly stable in the acetic acid effluent. The maximum sorption capacity of the developed sorbent PEI-PSBF, coated with PEI (with M.W. of 75,000), was 121.28 ± 13.15 mg/g, which was much higher than those of ion exchange resins, TP214, Amberjet 4200, and M500. The PEI-PSBF could be successfully applied in the flow-through column system, showing 120 beds of breakthrough volume.

  5. Ruthenium recovery from acetic acid industrial effluent using chemically stable and high-performance polyethylenimine-coated polysulfone-Escherichia coli biomass composite fibers

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sok [Division of Environmental Science and Ecological Engineering, College of Life Sciences and Biotechnology, Korea University, Seoul 02841 (Korea, Republic of); Division of Semiconductor and Chemical Engineering, Chonbuk National University, Jeonbuk 54896 (Korea, Republic of); Choi, Yoon-E, E-mail: yechoi@korea.ac.kr [Division of Environmental Science and Ecological Engineering, College of Life Sciences and Biotechnology, Korea University, Seoul 02841 (Korea, Republic of); Yun, Yeoung-Sang, E-mail: ysyun@jbnu.ac.kr [Division of Semiconductor and Chemical Engineering, Chonbuk National University, Jeonbuk 54896 (Korea, Republic of); Department of Bioprocess Engineering, Chonbuk National University, Jeonbuk 54896 (Korea, Republic of)

    2016-08-05

    Highlights: • The PEI-PSBF was fabricated and used for Ru recovery from industrial effluent. • PEI-PSBF was not swollen nor dissolved in the effluent. • PEI-PSBF showed superior sorption capacity to commercial resins. • Thin fiber type PEI-PSBF could be successfully applied in flow-through column. - Abstract: Recovery of precious metal ions from waste effluents is of high concern. In general, ruthenium (Ru) is used in the Cativa process as promoter for carbonylation catalyst and discharged into acetic acid effluent. In the present work, we have designed and developed polyethylenimine-coated polysulfone-bacterial biomass composite fiber (PEI-PSBF) to recover Ru from industrial effluent. The sorbent was manufactured by electrostatic attachment of polyethylenimine (PEI) to the surface of polysulfone-biomass composite fiber (PSBF), which was prepared through spinning of the mixture of polysulfone and Escherichia coli biomass in N,N-dimethylformamide (DMF) into water. Developed PEI-PSBF was highly stable in the acetic acid effluent. The maximum sorption capacity of the developed sorbent PEI-PSBF, coated with PEI (with M.W. of 75,000), was 121.28 ± 13.15 mg/g, which was much higher than those of ion exchange resins, TP214, Amberjet 4200, and M500. The PEI-PSBF could be successfully applied in the flow-through column system, showing 120 beds of breakthrough volume.

  6. Load-Bearing Capacity of Roof Trusses

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Damkilde, Lars; Munch-Andersen, J.

    2004-01-01

    systems such as roof trusses are established and statistical characteristics of the load bearing capacity are determined. The results show that there is a significant increase in the characteristic (nominal) value and a reduction in the coefficient of variation (COV) for typical loads such as permanent...

  7. The 3rd power unit roofing decontamination

    International Nuclear Information System (INIS)

    Samojlenko, Yu.N.; Golubev, V.V.

    1989-01-01

    The most features of the 3rd power unit (PU) roofing decontamination are described: 1) the most active materials were thrown into the 4th PU ruins before the Ukrytie construction completion; 2) the decontamination was fulfilled using remote-controlled mechanisms and manual devices (the main part). 6 figs.; 1 tab

  8. Rating system for coal mine roofs

    CSIR Research Space (South Africa)

    Canbulat, I

    2002-09-01

    Full Text Available It is standard practice in the majority of rock engineering applications to use a rock mass classification method to evaluate the condition of rock, i.e. to quantify, in an objective manner, the characteristics of good or bad roof. These rockmass...

  9. Design breakthrough in roof support systems

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    The technical experts of the Mining Services sections of Monier Resources Australia have designed and developed a superior roof system for installation in underground mines. The Monier Big Bag Grout Chock is a patented system utilising pumped grout. The advantages of grout chocks over conventional timber chocks are many and varied.

  10. Collaborative integral design of active roofs

    NARCIS (Netherlands)

    Zeiler, W.; Quanjel, E.M.C.J.; Borsboom, W.A.

    2009-01-01

    The application of photo-voltaic elements is the most economical on the roof. Still this often leads to severe problems due to poor coordination of all the design and practical aspects involved. This paper describes the research methodology, based on Methodical Design, as used in a design approach

  11. Accidents due to falls from roof slabs.

    Science.gov (United States)

    Rudelli, Bruno Alves; Silva, Marcelo Valerio Alabarce da; Akkari, Miguel; Santili, Claudio

    2013-01-01

    CONTEXT AND OBJECTIVE Falls from the roof slabs of houses are accidents of high potential severity that occur in large Brazilian cities and often affect children and adolescents. The aims of this study were to characterize the factors that predispose towards this type of fall involving children and adolescents, quantify the severity of associated lesions and suggest preventive measures. DESIGN AND SETTING Descriptive observational prospective longitudinal study in two hospitals in the metropolitan region of São Paulo. METHODS Data were collected from 29 cases of falls from roof slabs involving children and adolescents between October 2008 and October 2009. RESULTS Cases involving males were more prevalent, accounting for 84%. The predominant age group was schoolchildren (7 to 12 years old; 44%). Leisure activities were most frequently being practiced on the roof slab at the time of the fall (86%), and flying a kite was the most prevalent game (37.9%). In 72% of the cases, the children were unaccompanied by an adult responsible for them. Severe conditions such as multiple trauma and traumatic brain injuries resulted from 79% of the accidents. CONCLUSION Falls from roof slabs are accidents of high potential severity, and preventive measures aimed towards informing parents and guardians about the dangers and risk factors associated with this type of accident are needed, along with physical protective measures, such as low walls around the slab and gates with locks to restrict free access to these places.

  12. Accidents due to falls from roof slabs

    Directory of Open Access Journals (Sweden)

    Bruno Alves Rudelli

    Full Text Available CONTEXT AND OBJECTIVE Falls from the roof slabs of houses are accidents of high potential severity that occur in large Brazilian cities and often affect children and adolescents. The aims of this study were to characterize the factors that predispose towards this type of fall involving children and adolescents, quantify the severity of associated lesions and suggest preventive measures. DESIGN AND SETTING Descriptive observational prospective longitudinal study in two hospitals in the metropolitan region of São Paulo. METHODS Data were collected from 29 cases of falls from roof slabs involving children and adolescents between October 2008 and October 2009. RESULTS Cases involving males were more prevalent, accounting for 84%. The predominant age group was schoolchildren (7 to 12 years old; 44%. Leisure activities were most frequently being practiced on the roof slab at the time of the fall (86%, and flying a kite was the most prevalent game (37.9%. In 72% of the cases, the children were unaccompanied by an adult responsible for them. Severe conditions such as multiple trauma and traumatic brain injuries resulted from 79% of the accidents. CONCLUSION Falls from roof slabs are accidents of high potential severity, and preventive measures aimed towards informing parents and guardians about the dangers and risk factors associated with this type of accident are needed, along with physical protective measures, such as low walls around the slab and gates with locks to restrict free access to these places.

  13. An investigation into the potential use and sustainability of surfactant coated turfgrass seed for the green industry

    Science.gov (United States)

    Fidanza, Michael; McMillan, Mica; Kostka, Stan; Madsen, Matthew D.

    2014-05-01

    Turfgrass seed germination and emergence is influenced mostly by water and oxygen availability, temperature, nutrition and biological activity in the rootzone. In many areas globally, seed germination and subsequent turfgrass establishment is greatly diminished due to inadequate irrigation water amount and quality, and the problem is further compound due to water repellent soils. Successful turfgrass seed germination is critical when attempting to establish a more sustainable turfgrass species in place of an existing, high-input required turf stand. Greenhouse research investigations were conducted in 2013 in Pennsylvania (USA), to evaluate surfactant coated perennial ryegrass (Lolium perenne) and Kentucky bluegrass (Poa pratensis) seed for germination and emergence, seedling vigor and overall turfgrass quality. Both turfgrasses tested are cool-season or C3 grasses, and perennial ryegrass has a bunch-type growth habit while Kentucky bluegrass is rhizomatous. Perennial ryegrass is used world-wide as a principal component in sports turf mixes and in overseeding programs, and typically germinates rapidly in 3 to 10 days after seeding. Kentucky bluegrass also is used world-wide for sports turf as well as lawns and landscapes, and germinates slowly in 7 to 28 days. Research results indicate that surfactant coated seed of both species germinated one to three days faster compared to uncoated seed, and that seedling vigor and overall turfgrass quality was better with surfactant coated seed compared to uncoated seed. In a study with only perennial ryegrass, surfactant-coated seed without fertilizer (i.e., N and Ca) applied at time of sowing resulted in seedling vigor and quality considered to be similar or better than uncoated seed with fertilizer applied at time of sowing. Therefore, the potential benefits with seed germination and emergence, and seedling vigor and turfgrass quality also may be attributed to the surfactant coating and not only a fertilizer response. The

  14. TASK 2.5.7 FIELD EXPERIMENTS TO EVALUATE COOL-COLORED ROOFING

    Energy Technology Data Exchange (ETDEWEB)

    Miller, William A [ORNL; Cherry, Nigel J [ORNL; Allen, Richard Lowell [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL; Ronnen, Levinson [Lawrence Berkeley National Laboratory (LBNL); Akbari, Hashem [Lawrence Berkeley National Laboratory (LBNL); Berhahl, Paul [Lawrence Berkeley National Laboratory (LBNL)

    2010-03-01

    the attic and the whole building. Field measures and computer predictions showed that the demonstration home without a NIR-reflective tile coating and without above-sheathing ventilation had the greatest roof deck heat flow and subsequently the highest electrical usage. The house with both NIR paint pigments on the tile and with ASV had the least deck heat flows and therefore caused the home to consume the least amount of energy. The relative performance of the reflective coating and the ventilation individually is less obvious, but it is clear that the combination of a reflective tile with ASV is the preferred solution for the best energy saving.

  15. Protective Coatings

    Science.gov (United States)

    1980-01-01

    General Magnaplate Corporation's pharmaceutical machine is used in the industry for high speed pressing of pills and capsules. Machine is automatic system for molding glycerine suppositories. These machines are typical of many types of drug production and packaging equipment whose metal parts are treated with space spinoff coatings that promote general machine efficiency and contribute to compliance with stringent federal sanitation codes for pharmaceutical manufacture. Collectively known as "synergistic" coatings, these dry lubricants are bonded to a variety of metals to form an extremely hard slippery surface with long lasting self lubrication. The coatings offer multiple advantages; they cannot chip, peel or be rubbed off. They protect machine parts from corrosion and wear longer, lowering maintenance cost and reduce undesired heat caused by power-robbing friction.

  16. Roof windows in low-energy buildings - Analyses of demands and possibilities for future product development

    DEFF Research Database (Denmark)

    Skarning, Gunnlaug Cecilie Jensen; Duer, Karsten; Hviid, Christian Anker

    As part of an ambitious energy policy and strategy for reducing the use of fossil fuels in the European Union, all new buildings are required to consume `nearly zero-energy' by the end of 2020. This creates a strong need for research in cost-effective solutions and technology that can help balance...... transmittances of about 40-70% could provide suffcient daylighting without overheating in the climates of Rome and Copenhagen, as long as they were located in rooms with a reasonable layout for daylighting and appropriate solar-control coating was used on solar exposed glazing. The same was true for sloped...... and horizontal roof windows with any choice of light transmittance in both climates. Roof-window thermal properties needed for flexibility were then identied by studying the effect of these options on space-heating demand in rooms representing various parts of a 11/2-storey house with a simplied floor plan and...

  17. Ecological Impacts of Replacing Traditional Roofs with Green Roofs in Two Urban Areas

    Directory of Open Access Journals (Sweden)

    Timothy Carter

    2008-01-01

    Full Text Available Urban land cover is dominated by impervious surface that degrades both terrestrial and aquatic ecosystems relative to predevelopment conditions. There are significant opportunities for designers of urban landscapes to use alternative land covers that have multiple functions, benefiting both human and nonhuman components of the urban ecosystem. Vegetated (green roofs are one form of alternative land cover that has shown the potential to provide a variety of ecological benefits in urban areas. We evaluated how stormwater retention, building energy and temperature, and rooftop habitat are influenced by the use of green roofs using test plots in Georgia and Massachusetts. Green roofs were shown to recreate part of the predevelopment hydrology through increasing interception, stormwater storage, evaporation, and transpiration on the rooftop and worked extremely well for small storm events. Temperature reductions were found on the green rooftop as compared to an asphalt surface, although other roof technologies that minimize temperatures, such as lighter colored membranes, provide similar benefits. Novel habitat was created on the rooftop, although the extent of this habitat was limited in part by plant survivability and the need for additional water inputs for diverse plant communities to survive. Despite the challenges, the green roof benefits reported here suggest that green roofs can be used effectively as a multifunctional land cover in urban areas.

  18. Performance evaluation on cool roofs for green remodeling

    Science.gov (United States)

    Yun, Yosun; Cho, Dongwoo; Cho, Kyungjoo

    2018-06-01

    Cool roofs refer that maximize heat emission, and minimize the absorption of solar radiation energy, by applying high solar reflectance paints, or materials to roofs or rooftops. The application of cool roofs to existing buildings does not need to take structural issues into consideration, as rooftop greening, is an alternative that can be applied to existing buildings easily. This study installed a cool roofs on existing buildings, and evaluated the performances, using the results to propose certification standards for green remodeling, considering the cool roof-related standards.

  19. Water quality function of an extensive vegetated roof.

    Science.gov (United States)

    Todorov, Dimitar; Driscoll, Charles T; Todorova, Svetoslava; Montesdeoca, Mario

    2018-06-01

    In this paper we present the results of a four-year study of water quality in runoff from an extensive, sedum covered, vegetated roof on an urban commercial building. Monitoring commenced seven months after the roof was constructed, with the first growing season. Stormwater drainage quality function of the vegetated roof was compared to a conventional (impermeable, high-albedo) membrane roof in addition to paired measurements of wet and bulk depositions at the study site. We present concentrations and fluxes of nutrients and major solutes. We discuss seasonal and year-to-year variation in water quality of drainage from the vegetated roof and how it compares with atmospheric deposition and drainage from the impermeable roof. Drainage waters from the vegetated roof exhibited a high concentration of nutrients compared to atmospheric deposition, particularly during the warm temperature growing season. However, nutrient losses were generally low because of the strong retention of water by the vegetated roof. There was marked variation in the retention of nutrients by season due to variations in concentrations in drainage from the vegetated roof. The vegetated roof was a sink of nitrogen, total phosphorus and chloride, and a source of phosphate and dissolved inorganic and organic carbon. Chloride exhibited elevated inputs and leaching during the winter. The drainage from the vegetated and impermeable roofs met the United States Environmental Protection Agency freshwater standards for all parameters, except for total phosphorus. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Protective coatings (paints) for the nuclear industry - approved standard 1974 - (revision and redesignation of N5.9-1967)

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    A standard is presented which provides a common basis on which protective coatings (paints) for surfaces in a nuclear complex may be compared and selected by reproducible tests. The environmental conditions of these complexes are such that a paint may be deteriorated by exposure to any, all, or a combination of the following conditions: ionizing radiation; contamination by radioactive nuclides and decontamination processes, chemicals; immersion in highly purified water; and abrasion or wear. This standard specifically applies to the surfaces of such facilities as reactors, fuel reprocessing plants, and laboratories and hot cells

  1. Development and characterization of ceramic composites alumina-titania based reinforced with lanthanum oxide for fabrication of inert coatings for metallic tanks of the oil industry

    International Nuclear Information System (INIS)

    Bandeira, J.M.; Yadava, Y.P.; Silva, N.D.G.; Ferreira, R.A.S.

    2016-01-01

    Crude petroleum is highly corrosive causing superficial degradation in metallic tanks used for storage and transportation of this material, which causes a serious problem in the oil industry. An alternative to solve this problem is to use some kind of coating that is inert to this kind of corrosion. Alumina and titania are interesting materials for several engineering applications because, when compared with other ceramic materials, they present superior mechanical properties, e.g. high mechanical strength, good chemical stability and high fracture toughness combined with good wear resistance and a coefficient of thermal expansion close to the iron's, which makes them fit to use in ceramic hardening process and coating. In this paper, alumina-titania ceramic composites with 5%, 10%, 15% and 20% of titania (TiO2) and reinforced with 2% of lanthanum oxide of were produced by thermo-mechanical processing and sintering techniques at 1350 deg C. In these composites, microstructure and mechanical properties were analyzed using X-ray spectroscopy, optical microscopy, scanning electron microscopy and Vickers hardness in order to evaluate their applicability. X-ray spectroscopy showed the formation of composite without the presence of other phases. Optical microscopy and scanning electron microscopy showed a homogeneous microstructure in terms of particle size and distribution. Vickers hardness test showed a gradual decrease in hardness with the addition of titania. The composite with 5% of titania and 2% of lanthanum oxide is the best choice for structural applications. The composites were submerged in crude petroleum for 30 days to study their stability in such environment. Through the analysis of X-ray spectroscopy, optical microscopy and Vickers hardness before and after the submersion in crude petroleum, it was not observed structural or microstructural degradation nether alterations in mechanical properties. This way, it was concluded that these composites have good

  2. Impact of modified diamond-like carbon coatings on the spatial organization and disinfection of mixed-biofilms composed of Escherichia coli and Pantoea agglomerans industrial isolates.

    Science.gov (United States)

    Gomes, L C; Deschamps, J; Briandet, R; Mergulhão, F J

    2018-07-20

    This work investigated the effects of diamond-like carbon (DLC) coatings on the architecture and biocide reactivity of dual-species biofilms mimicking food processing contaminants. Biofilms were grown using industrial isolates of Escherichia coli and Pantoea agglomerans on bare stainless steel (SST) and on two DLC surface coatings (a-C:H:Si:O designated by SICON® and a-C:H:Si designated by SICAN) in order to evaluate their antifouling activities. Quantification and spatial organization in single- and dual-species biofilms were examined by confocal laser scanning microscopy (CLSM) using a strain specific labelling procedure. Those assays revealed that the E. coli isolate exhibited a higher adhesion to the modified surfaces and a decreased susceptibility to disinfectant in presence of P. agglomerans than alone in axenic culture. While SICON® reduced the short-term growth of E. coli in axenic conditions, both DLC surfaces increased the E. coli colonization in presence of P. agglomerans. However, both modified surfaces triggered a significantly higher log reduction of E. coli cells within mixed-species biofilms, thus the use of SICON® and SICAN surfaces may be a good approach to facilitate the disinfection process in critical areas of food processing plants. This study presents a new illustration of the importance of interspecies interactions in surface-associated community functions, and of the need to evaluate the effectiveness of hygienic strategies with relevant multi-species consortia. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Green Roofs: Standardization and Quality Control of Processes in Green Construction

    Directory of Open Access Journals (Sweden)

    Korol Elena

    2017-01-01

    Full Text Available The article considers the problems of standardization and quality control of processes in the construction, improvement of integrated safety of buildings and the implementation of innovative green building technologies, the use of national standards as well as international rating systems for green buildings evaluation. This is one of the priority directions in development of the modern construction. The aim of this study is the analysis of the green roof systems and international standards, which were carried out in the green building industry. The authors have studied traditional and innovative solutions of rational using natural resources and energy, the green roof system with integration of supported solar and wind energy collecting and converting devices and of irrigation system. Some studies provide evidence for the benefits of the modular green roof system in urban green space with microclimate differences. This article presents a new research which advances our knowledge of the economic and environmental services provided by the green roof system. Research reported here also considers the analysis of the Russian and international legislation of the quality control of processes in green construction.

  4. Installation of a Roof Mounted Photovoltaic System

    Science.gov (United States)

    Lam, M.

    2015-12-01

    In order to create a safe and comfortable environment for students to learn, a lot of electricity, which is generated from coal fired power plants, is used. Therefore, ISF Academy, a school in Hong Kong with approximately 1,500 students, will be installing a rooftop photovoltaic (PV) system with 302 solar panels. Not only will these panels be used to power a classroom, they will also serve as an educational opportunity for students to learn about the importance of renewable energy technology and its uses. There were four different options for the installation of the solar panels, and the final choice was made based on the loading capacity of the roof, considering the fact that overstressing the roof could prove to be a safety hazard. Moreover, due to consideration of the risk of typhoons in Hong Kong, the solar panel PV system will include concrete plinths as counterweights - but not so much that the roof would be severely overstressed. During and after the installation of the PV system, students involved would be able to do multiple calculations, such as determining the reduction of the school's carbon footprint. This can allow students to learn about the impact renewable energy can have on the environment. Another project students can participate in includes measuring the efficiency of the solar panels and how much power can be produced per year, which in turn can help with calculate the amount of money saved per year and when we will achieve economic parity. In short, the installation of the roof mounted PV system will not only be able to help save money for the school but also provide learning opportunities for students studying at the ISF Academy.

  5. Roof timber for fortifying mining works

    Energy Technology Data Exchange (ETDEWEB)

    Shirokov, A P; Kuntsevich, V IK; Pishchulin, V V; Seryi, A M; Volkov, P A

    1981-05-15

    The roof timber for fortifying mining works includes spring-mounted hinged elements made from a special rolled metal. In order to increase the carrying capacity of the support by increasing the deformation threshold, the springs are mounted by their expanded section to the lower side of the hinge; their ends are connected in turn to the elements made from the special rolled metal on both sides of the hinge.

  6. Electro-mechanical properties of REBCO coated conductors from various industrial manufacturers at 77 K, self-field and 4.2 K, 19 T

    International Nuclear Information System (INIS)

    Barth, C; Mondonico, G; Senatore, C

    2015-01-01

    Rare-Earth-barium–copper–oxide tapes are now available from several industrial manufacturers and are very promising conductors in high field applications. Due to diverging materials and deposition processes, these manufacturers’ tapes can be expected to differ in their electro-mechanical and mechanical properties. For magnets designers, these are together with the conductors’ in-field critical current performance of the highest importance in choosing a suitable conductor. In this work, the strain and stress dependence of the current carrying capabilities as well as the stress and strain correlation are investigated for commercial coated conductors from Bruker HTS, Fujikura, SuNAM, SuperOx and SuperPower at 77 K, self-field and 4.2 K, 19 T. (paper)

  7. The detection of the coal roof interface by use of high pressure water

    Science.gov (United States)

    1981-01-01

    A device whereby water jets can be used to detect the interface between coal and the overlying roof rock is described. Once this identification is made this distance can be measured using instruments such as the autofocus systems recently developed in the photographic industry. Experiments carried out show that the device can discriminate between coal and rock at coal thicknesses up to 8 inches. An autofocus system was examined which indicates accuracies of better than 0.1 inches.

  8. Perspectives of roof bolt use in the Kuzbass

    Energy Technology Data Exchange (ETDEWEB)

    Shirokov, A P

    1983-10-01

    Use of roof bolting for strata control in mine roadways and underground chambers in Kuzbass mines is discussed. Use of roof bolting in the Kuzbass is increasing. In 1982 roof bolting was used in 50% of workings driven in the basin; in 15 coal mines roof bolting was the predominant method for strata control. Use of roof bolting rather than timber props permitted advance rate of mine drivage in the Kuzbass to be increased by 1.5-2.0 times. Interaction between roof bolts and rock strata is analyzed. The following bolt types are considered: timber roof bolts, steel expansion shell bolts and thread bar bolts. Bolt design is shown, along with methods for roof bolt installation in roadways and chambers. Roof bolting during level, inclined or steep seam mining, for strata control at junctions of working faces with gate roads, at junctions of 2 roadways, in coal chutes, in hydraulic mines, during thick seam slicing with hardening stowing and longwall mining with hydraulic stowing is analyzed. Effects of roof bolting on strata control efficiency in steep coal mines employing AShchM systems are evaluated.

  9. Creating a marketplace for green roofs in Chicago

    International Nuclear Information System (INIS)

    Vitt Sale, L.; Berkshire, M.

    2004-01-01

    Since 2003, the Chicago Department of Planning and Development has been encouraging city developers to consider installing green roofs on buildings in Chicago, with the belief that this practice results in mitigation of the urban heat island effect, cleaner runoff leaving green roofs, sound attenuation, aesthetic value, oxygen production, and mitigation of carbon dioxide emissions. However, the benefits to developers, which include reduced stormwater runoff, extended roof life and energy savings, in total do not offset the first cost premium of a green roof. Despite this, and with no mandate requiring green roofs, the marketplace is growing. After seeing green roofs on a tour in Europe, the mayor of Chicago encouraged the first design and installation of a 20,300 square foot demonstration green roof in Chicago, and other city-sponsored pilot projects followed shortly after. Since then, the number of green roofs in Chicago has grown to over one million square feet. A map of Chicago showing locations of most of the projects was presented. It was suggested that lower prices for green roofs, higher energy costs and an inclination to invest in long-term strategies would accelerate the market. In an effort to engage the public in dialogue, the Department of Planning and Development held seminars to promote the benefits of green roofs . Participants had many questions about the applicability of green roofs to Chicago, expressing skepticism that Chicago's climate would provide the same benefits as in Europe. Other concerns were expressed regarding the devaluation of property values resulting from placing green roofs on buildings; doubts about roof leaks; maintenance practices; and, bugs and mold. Since the first cost premium of the system remains a question, most participants expressed interest in some kind of incentive program, but remained open-minded if benefits could be proved. 6 figs

  10. Creating a marketplace for green roofs in Chicago

    Energy Technology Data Exchange (ETDEWEB)

    Vitt Sale, L. [Wright and Co. Chicago, IL (United States); Berkshire, M. [City of Chicago, IL (United States)

    2004-07-01

    Since 2003, the Chicago Department of Planning and Development has been encouraging city developers to consider installing green roofs on buildings in Chicago, with the belief that this practice results in mitigation of the urban heat island effect, cleaner runoff leaving green roofs, sound attenuation, aesthetic value, oxygen production, and mitigation of carbon dioxide emissions. However, the benefits to developers, which include reduced stormwater runoff, extended roof life and energy savings, in total do not offset the first cost premium of a green roof. Despite this, and with no mandate requiring green roofs, the marketplace is growing. After seeing green roofs on a tour in Europe, the mayor of Chicago encouraged the first design and installation of a 20,300 square foot demonstration green roof in Chicago, and other city-sponsored pilot projects followed shortly after. Since then, the number of green roofs in Chicago has grown to over one million square feet. A map of Chicago showing locations of most of the projects was presented. It was suggested that lower prices for green roofs, higher energy costs and an inclination to invest in long-term strategies would accelerate the market. In an effort to engage the public in dialogue, the Department of Planning and Development held seminars to promote the benefits of green roofs . Participants had many questions about the applicability of green roofs to Chicago, expressing skepticism that Chicago's climate would provide the same benefits as in Europe. Other concerns were expressed regarding the devaluation of property values resulting from placing green roofs on buildings; doubts about roof leaks; maintenance practices; and, bugs and mold. Since the first cost premium of the system remains a question, most participants expressed interest in some kind of incentive program, but remained open-minded if benefits could be proved. 6 figs.

  11. Asbestos Standard for the Construction Industry

    National Research Council Canada - National Science Library

    1995-01-01

    .... In the construction industry, asbestos is found in installed products such as shingles, floor tiles, cement pipe and sheet, roofing felts, insulation, ceiling tiles, fire-resistant drywall, and acoustical products...

  12. Characterization of reflectance variability in the industrial paint application of automotive metallic coatings by using principal component analysis

    Science.gov (United States)

    Medina, José M.; Díaz, José A.

    2013-05-01

    We have applied principal component analysis to examine trial-to-trial variability of reflectances of automotive coatings that contain effect pigments. Reflectance databases were measured from different color batch productions using a multi-angle spectrophotometer. A method to classify the principal components was used based on the eigenvalue spectra. It was found that the eigenvalue spectra follow distinct power laws and depend on the detection angle. The scaling exponent provided an estimation of the correlation between reflectances and it was higher near specular reflection, suggesting a contribution from the deposition of effect pigments. Our findings indicate that principal component analysis can be a useful tool to classify different sources of spectral variability in color engineering.

  13. Development of a pneumatic roof envelope for industrial greenhouses

    NARCIS (Netherlands)

    Lindner, G.; Vos, de G.J.

    2008-01-01

    The Eindhoven University of Technology (TU/e) was approached by Van Diemen BV, a turn-key greenhouse builder looking for a new and higher insulated design for their green house envelope. They had developed a new system of climate control which rendered windows for ventilation purposes unnecessary

  14. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    Energy Technology Data Exchange (ETDEWEB)

    Syd S. Peng

    2005-01-15

    In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The main accomplishments in this quarter included: (1) one more field test has been conducted in an underground coal mine, (2) optimization studies of the control parameters have been conducted, (3) method to use torque to thrust ratio as indicator of rock relative hardness has also been explored, and (4) about 98% of the development work for the roof geology mapping program, MRGIS, has completed, (5) A real time roof geology mapping system for roof bolters in limestone mine, including a special version of the geology mapping program and hardware, has already been verified to perform very well in underground production condition.

  15. Variations of PV Panel Performance Installed over a Vegetated Roof and a Conventional Black Roof

    Directory of Open Access Journals (Sweden)

    Mohammed J. Alshayeb

    2018-05-01

    Full Text Available The total worldwide photovoltaic (PV capacity has been growing from about 1 GW at the beginning of the twenty-first century to over 300 GW in 2016 and is expected to reach 740 GW by 2022. PV panel efficiency is reported by PV manufacturers based on laboratory testing under Standard Testing Condition with a specific temperature of 25 °C and solar irradiation of 1000 W/m2. This research investigated the thermal interactions between the building roof surface and PV panels by examining the differences in PV panel temperature and energy output for those installed over a green roof (PV-Green and those installed over a black roof (PV-Black. A year-long experimental study was conducted over the roof of an educational building with roof mounted PV panels with a system capacity of 4.3 kW to measure PV underside surface temperature (PV-UST, ambient air temperature between PV panel and building roof (PV-AT, and PV energy production (PV-EP. The results show that during the summer the PV-Green consistently recorded lower PV-UST and PV-AT temperatures and more PV-EP than PV-Black. The average hourly PV-EP difference was about 0.045 kWh while the maximum PV-EP difference was about 0.075 kWh, which represents roughly a 3.3% and 5.3% increase in PV-EP. For the entire study period, EP-Green produced 19.4 kWh more energy, which represents 1.4% more than EP-Black.

  16. Anticorrosive coatings: a review

    DEFF Research Database (Denmark)

    Sørensen, Per Aggerholm; Kiil, Søren; Dam-Johansen, Kim

    2009-01-01

    of volatile organic compounds (VOCs) have caused significant changes in the anticorrosive coating industry. The requirement for new VOC-compliant coating technologies means that coating manufacturers can no longer rely on the extensive track record of their time-served products to convince consumers...... of their suitability for use. An important aspect in the development of new VOC-compliant, high-performance anticorrosive coating systems is a thorough knowledge of the components in anticorrosive coatings, their interactions, their advantages and limitations, as well as a detailed knowledge on the failure modes......, and inhibitive coatings are outlined. In the past decades, several alternatives to organic solvent-borne coatings have reached the commercial market. This review also presents some of these technologies and discusses some of their advantages and limitations. Finally, some of the mechanisms leading to degradation...

  17. Cool roofs with high solar reflectance for the welfare of dairy farming animals

    International Nuclear Information System (INIS)

    Santunione, G; Libbra, A; Muscio, A

    2017-01-01

    Ensuring livestock welfare in dairy farming promotes the production capacity of the animals in terms of both quantity and quality. In welfare conditions, the animals can produce at their full potential. For the dairy cattle the most debilitating period of the year is summer, when the stress arising from overheating induces physiological alterations that compromise the animals’ productivity. In this study, the summer discomfort of dairy animals is primarily quantified and the production loss is quantified versus the Temperature Humidity Index (THI), which correlates the values of temperature and relative humidity to the thermal stress. In order to reduce or eliminate such thermal stress, it is then proposed to coat the roof of the stables with a paint having high solar reflectance and thermal emittance, that is a cool roof product. This type of roofing solution can considerably limit the overheating of stables caused by solar radiation, thus providing a positive impact on the animals’ welfare and improving significantly their productivity in summer. (paper)

  18. Green Roofs: Federal Energy Management Program (FEMP) Federal Technology Alert

    Energy Technology Data Exchange (ETDEWEB)

    Scholz-Barth, K.; Tanner, S.

    2004-09-01

    In a ''green roof,'' a layer of vegetation (e.g., a roof garden) covers the surface of a roof to provide shade, cooler indoor and outdoor temperatures, and effective storm-water management to reduce runoff. The main components are waterproofing, soil, and plants. There are two basic kinds: intensive and extensive. An intensive green roof often features large shrubs and trees, and it can be expensive to install and maintain. An extensive green roof features shallow soil and low-growing, horizontally spreading plants that can thrive in the alpine conditions of many rooftops. These plants do not require a lot of water or soil, and they can tolerate a significant amount of exposure to the sun and wind. This Federal Technology Alert focuses on the benefits, design, and implementation of extensive green roofs and includes criteria for their use on federal facilities.

  19. Application of solar roof shallow pool at individual residental buildings

    OpenAIRE

    Gavrilović Dragan J.

    2011-01-01

    The paper discusses the possibility of applying shallow roof pools of water on the basis of passive solar water capture functioning as thermal batteries and thermal "regulators" in a "hot - cold" mode with individual residential buildings. With this application, the utilization of the existing functionality of the building roof area would improve and open up the possibility of achieving better overall bio-climate individual object. By using this system, a flat roof impassable "terrace" ...

  20. The Self-Drying Concept for Flat Roofs

    DEFF Research Database (Denmark)

    Korsgaard, Vagn; Bunch-Nielsen, Tommy; Rode, Carsten

    1996-01-01

    ways. From the interior by diffusion and convection. During construction from moist materials or rain. Later on, rain water may enter through leaks in the roofing.From laboratory experiment, computer calculations and practical experience it is concluded, that the Self-Drying Roof concept works for both...... cold- and warm deck roof systems in climate zones where a vapor retarder is needed, if the traditional water proof vapor retarder is substituted by a water permeable vapor retarder....

  1. EVALUACIÓN DE UN RECUBRIMIENTO FORMULADO CON BASE EN PINTURA INDUSTRIAL Y EXTRACTO DE Aloe saponaria EXPUESTO A LA ATMÓSFERA MARINA I EVALUATION OF A COATING MADE FROM INDUSTRIAL PAINT BASE AND EXTRACT OF Aloe saponaria EXPOSED TO MARINE ATMOSPHERE

    Directory of Open Access Journals (Sweden)

    Asyuri del Valle Roquez Ramos

    2018-04-01

    Full Text Available A base of industrial paint mixed with extract of plants of the genus Aloe was evaluated as a possible corrosion inhibiting coating. A phosphate buffered saline solution (BFS was used to prepare the aqueous extract of Aloe saponaria and mixtures were prepared based industrial paint and the aqueous extract at different ratios (80:20, 70:30, 60:40, 50:50. Plates of AA3003 aluminum alloy were coated and exposed to the marine atmosphere using the Sucre Atmospheric Corrosion Station I, located in the zone of Turpialito in the south of Gulf of Cariaco, Sucre State. To characterize the industrial paint base, extract and mixtures (base:extract, the Fourier transform infrared spectroscopy (FT-IR was used, while the evaluation of the coatings was carried out once a month by visual inspection, photographic record and optical microscopy. The results of FT-IR identified functional groups of esters and hydrocarbons in all mixtures (base:extract, which are also present both in painting and in extract. Coatings formulated with the base paint and Aloe saponaria extract exhibited better performance against the marine atmosphere compared to coating with paint alone, the latter having blistering degradation. This behavior suggests that the aqueous extract may be acting as a stabilizer in coatings (base paint:extract against aggressive media and showed no blistering and maintained their consistency during the duration of the experiment.

  2. Phosphate Leaching from Green Roof Substrates—Can Green Roofs Pollute Urban Water Bodies?

    Directory of Open Access Journals (Sweden)

    Agnieszka Karczmarczyk

    2018-02-01

    Full Text Available Green roofs are an effective stormwater measure due to high water retention capacity and the ability of delaying stormwater runoff. However, low importance is still given to the pollutant leaching potential of substrates used in green roof construction. The aim of the study is to estimate the concentrations and loads of P-PO43− in runoff from extensive and intensive substrates. To achieve this goal, several commonly-used fresh substrates were analyzed for P-PO43− leaching potential in different scale experiments, from laboratory batch tests, leaching column experiments, and long-term monitoring of open air green roof containers. The results of the study confirmed that fresh green roof substrates contain phosphorus in significant amounts of 17–145 mg∙P-PO43−/kg and, thus, can contribute to eutrophication of freshwater ecosystems. High correlation between phosphate content estimated by HCl extraction and cumulative load in leachate tests suggests that the batch HCl extraction test can be recommended for the comparison and selection of substrates with low potential P leaching. Volume-weighted mean concentrations and UALs of P-PO43− leaching from fresh substrates were higher in cases of intensive substrates, but there was no clear relationship between substrate type and the observed P-PO43− concentration range. To avoid increasing eutrophication of urban receivers the implementation of P reduction measures is strongly recommended.

  3. Roof renovation of buildings 128 and 129

    CERN Multimedia

    2015-01-01

    The roof renovation of buildings 128 and 129 is scheduled to take place from 17 August to 15 October 2015.   During this period, access to the "raw material" workshop will be limited and controlled due to asbestos removal. Collecting your orders directly from the building will be difficult, or even impossible, and urgent requests will be difficult to carry out. We therefore ask you to create your requests via EDH, so that delivery may be carried out as soon as possible. Thank you for your understanding. GS Department

  4. Time focused measurements of roof runoff quality

    International Nuclear Information System (INIS)

    Schriewer, A.; Horn, H.; Helmreich, B.

    2008-01-01

    Runoff properties and their changes during runoff of a 14 year old zinc roof were investigated. Zinc, lead, cadmium, pH value, rain intensity and electric conductivity have been measured for a period of one year. A runoff rate of 3.73 g/m 2 a and a volume weighted mean zinc concentration of 4.9 mg/L were determined. First flush behaviour was observed in 93% of runoff events. Low rain intensities are correlating with higher zinc concentrations in runoff, whereas the duration of antecedent dry periods could not directly be linked with initial zinc concentrations

  5. Effective roof support for tabular stopes.

    CSIR Research Space (South Africa)

    Ottermann, RW

    2002-09-01

    Full Text Available hydraulic press of the servo hydraulic test facility of the University of Pretoria. The yielding mechanism was compressed at a constant speed of 10 mm/min and the force displacement characteristics was recorded. See figure 4-18. After reaching... damper absorbing the forces. The test of the yielding mechanism was done in a servo hydraulic press as described in paragraph 4.4.2. 5.1.2 Laboratory tests The load cycle chosen for the testing of the structure of the roof support system was: 5...

  6. Review of Thermal Spray Coating Applications in the Steel Industry: Part 2—Zinc Pot Hardware in the Continuous Galvanizing Line

    Science.gov (United States)

    Matthews, S.; James, B.

    2010-12-01

    This two-part article series reviews the application of thermal spray coating technology in the production of steel and steel sheet products. Part 2 of this article series is dedicated to coating solutions in the continuous galvanizing line. The corrosion mechanisms of Fe- and Co-based bulk materials are briefly reviewed as a basis for the development of thermal spray coating solutions. WC-Co thermal spray coatings are commonly applied to low Al-content galvanizing hardware due to their superior corrosion resistance compared to Fe and Co alloys. The effect of phase degradation, carbon content, and WC grain size are discussed. At high Al concentrations, the properties of WC-Co coatings degrade significantly, leading to the application of oxide-based coatings and corrosion-resistant boride containing coatings. The latest results of testing are summarized, highlighting the critical coating parameters.

  7. A green roof grant program for Washington DC

    International Nuclear Information System (INIS)

    Johnson, P.A.

    2007-01-01

    The Chesapeake Bay Foundation (CBF) began its green roof demonstration project with $300,000 in funding provided by the DC Water and Sewer Authority. This paper reviewed the history of the project, its goals and early findings. The main objective was to demonstrate the technical, policy and economic feasibility of installing green roofs on commercial buildings in Washington DC and to promote green roofs as a means to manage storm water and improve water quality through the reduction of excessive runoff. The CBF has issued grants for the installation of 7 green roofs varying in size, design, location, and use. The projects included both new and existing structures designed to improve storm-water management in an urban area with significant pollution stress on the adjacent rivers. This paper provided technical, cost, and performance evaluations of each roof. A public outreach segment provided information to decision-makers to encourage more widespread replication of green roof technology throughout the metropolitan area. Much of the District of Columbia is served by a combined sewer system that becomes overloaded and discharges raw sewage into adjacent rivers during even moderately heavy rains. An average of 75 overflow events each year result in 1.5 billion gallons discharged into the Anacostia River. The installation of green roofs on buildings in the combined sewer area would retain storm water during these heavy rains and reduce the amount of overflow discharges. Apartments, as well as commercial and government buildings with mostly flat roofs are the most likely candidates for green roofs. The demonstration roofs are intended to become models, which all building owners could use as a guide for future plans for construction or re-construction to expand green roof coverage in Washington DC. It was emphasized that although such large-scale replication will take time and financial investments, it is achievable given enough political will and commercial awareness of

  8. Comparing wildlife habitat and biodiversity across green roof type

    Energy Technology Data Exchange (ETDEWEB)

    Coffman, R.R. [Oklahoma Univ., Tulsa, OK (United States). Dept. of Landscape Architecture

    2007-07-01

    Green roofs represent restorative practices within human dominated ecosystems. They create habitat, increase local biodiversity, and restore ecosystem function. Cities are now promoting this technology as a part of mitigation for the loss of local habitat, making the green roof necessary in sustainable development. While most green roofs create some form of habitat for local and migratory fauna, some systems are designed to provide specific habitat for species of concern. Despite this, little is actually known about the wildlife communities inhabiting green roofs. Only a few studies have provided broad taxa descriptions across a range of green roof habitats, and none have attempted to measure the biodiversity across green roof class. Therefore, this study examined two different vegetated roof systems representative of North America. They were constructed under alternative priorities such as energy, stormwater and aesthetics. The wildlife community appears to be a result of the green roof's physical composition. Wildlife community composition and biodiversity is expected be different yet comparable between the two general types of green roofs, known as extensive and intensive. This study recorded the community composition found in the two classes of ecoroofs and assessed biodiversity and similarity at the community and group taxa levels of insects, spiders and birds. Renyi family of diversity indices were used to compare the communities. They were further described through indices and ratios such as Shannon's, Simpson's, Sorenson and Morsita's. In general, community biodiversity was found to be slightly higher in the intensive green roof than the extensive green roof. 26 refs., 4 tabs., 4 figs.

  9. Effects of roof tile permeability on the thermal performance of ventilated roofs. Analysis of annual performance

    Energy Technology Data Exchange (ETDEWEB)

    D' Orazio, M.; Di Perna, C.; Principi, P.; Stazi, A. [DACS, Universita politecnica delle Marche, 60100 Ancona (Italy)

    2008-07-01

    This paper shows the results of the second part of an experimental study aimed at analysing the effects of roof tile permeability on the thermal performances of ventilation ducts. Ventilation ducts under the layer of tiles are typically used in south European countries to limit the energy load during the summer period. The results of the first part of the study, carried out by analysing 14 different types of roof, proved that the air permeability of the layer of tiles determines a certain amount of heat to be released, in addition to the release connected with the stack effect, in ventilation ducts which have the same characteristics but are perfectly airtight. However, the study did not completely resolve some issues since it was carried out on a model roof (6 m x 1.5 m) with devices to raise the layer of tiles and to create the ventilation duct but without those building elements which are present in real roofs and are used to stop insects and small animals from entering the ventilation duct. These elements narrow the inlet and outlet and consequently cause important reductions in pressure. Moreover, the measurements were based on data collected for limited periods of time during the summer season. So as to eliminate any possible uncertainty from the results of the research, the study continued with the creation of a model building on which five types of ventilated roof with different cross sections of the ventilation duct were analysed. The results show that the presence of air permeable layers and elements to protect the ventilation duct eliminate any differences in performance which were due to the cross section of the ventilation duct. (author)

  10. Visual recognition of the load of roof-bolts by an indicator

    Energy Technology Data Exchange (ETDEWEB)

    Leonhardt, J. [Leon Industries (Germany)

    2001-07-01

    Hundreds of bolt-indicators were already used successfully in the German deep hard coal-mines to increase the safety and economy. The bolt-indicator offers the simple possibility to guard roof-bolt loads, to state weak points as well as to optimize the anchor density and the dimension. The bolt-indicator are mushroom shaped and are of coated metal. It is brought in between the anchor plate and the anchor mother. The loads appearing at the anchor will transfer to the bolt-indicators and can be recognized visually at the cylindrical part by the amount of the surface coating. A select example clarifies itself application aims, operation and a usage of the bolt-indicator and the yielding advantages in practice. (orig.)

  11. A Model of Equilibrium Conditions of Roof Rock Mass Giving Consideration to the Yielding Capacity of Powered Supports

    Science.gov (United States)

    Jaszczuk, Marek; Pawlikowski, Arkadiusz

    2017-12-01

    units giving consideration to the load of the caving shield, a model of support unit was used that allows for unequivocal determination of the yielding capacity of the support with consideration given to the height of the unit in use and the change in the inclination of the canopy resulting from the displacement of the roof of the longwall. The yielding capacity of the support unit and its point of application on the canopy was determined using the method of units which allows for the internal forces to be manifested. The weight of the rock mass depends on the geological and mining conditions, for which the shape and dimensions of the rock mass affecting the support unit are determined. The resultant force of the pressure of gob on the gob shield was calculated by assuming that the load may be understood as a pressure of ground on a wall. This required the specification of the volume of the fallen rocks that affect the unit of powered roof supports (Fig. 2). To determine the support of the roof rock mass by the coal seam, experience of the Australian mining industry was used. Experiments regarding the strength properties of coal have exhibited that vertical deformation, at which the highest seam reaction occurs while supporting the roof rock mass, amounts to 0.5% of the longwall's height. The measure of the width of the contact area between the rock mass and the seam is the width of the additional uncovering of the face roof due to spalling of seam topcorners da (Fig. 2). With the above parameters and the value of the modulus of elasticity of coal in mind, the value of the seam's reaction may be estimated using the dependence (2). The vertical component of the goafs' reaction may be determined based on the strength characteristics of the fallen roof, the contact area of the rock mass with the fallen roof and the mean strain of the fallen roof at the area of contact. In the work by Pawlikowski (2014), a research procedure was proposed which encompasses model tests and

  12. Installation, care, and maintenance of wood shake and shingle roofs

    Science.gov (United States)

    Tony Bonura; Jack Dwyer; Arnie Nebelsick; Brent Stuart; R. Sam Williams; Christopher Hunt

    2011-01-01

    This article gives general guidelines for selection, installation, finishing, and maintenance of wood shake and shingle roofs. The authors have gathered information from a variety of sources: research publications on wood finishing, technical data sheets from paint manufacturers, installation instructions for shake and shingle roofs, and interviews with experts having...

  13. Comparative properties of ceramic-based roofing sheets from local ...

    African Journals Online (AJOL)

    Ceramic roofing sheets were fabricated in the laboratory by using ideal raw materials. The fabricating materials are coiled coconut fibre, palm fruit fibre, fresh water, river sand, polymeric dust, saw dust and cement. The resulting product was compared with factory -produced ceramic-based roofing sheets that are easily ...

  14. Fourier analysis of conductive heat transfer for glazed roofing materials

    Energy Technology Data Exchange (ETDEWEB)

    Roslan, Nurhana Lyana; Bahaman, Nurfaradila; Almanan, Raja Noorliyana Raja; Ismail, Razidah [Faculty of Computer and Mathematical Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor (Malaysia); Zakaria, Nor Zaini [Faculty of Applied Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor (Malaysia)

    2014-07-10

    For low-rise buildings, roof is the most exposed surface to solar radiation. The main mode of heat transfer from outdoor via the roof is conduction. The rate of heat transfer and the thermal impact is dependent on the thermophysical properties of roofing materials. Thus, it is important to analyze the heat distribution for the various types of roofing materials. The objectives of this paper are to obtain the Fourier series for the conductive heat transfer for two types of glazed roofing materials, namely polycarbonate and polyfilled, and also to determine the relationship between the ambient temperature and the conductive heat transfer for these materials. Ambient and surface temperature data were collected from an empirical field investigation in the campus of Universiti Teknologi MARA Shah Alam. The roofing materials were installed on free-standing structures in natural ventilation. Since the temperature data are generally periodic, Fourier series and numerical harmonic analysis are applied. Based on the 24-point harmonic analysis, the eleventh order harmonics is found to generate an adequate Fourier series expansion for both glazed roofing materials. In addition, there exists a linear relationship between the ambient temperature and the conductive heat transfer for both glazed roofing materials. Based on the gradient of the graphs, lower heat transfer is indicated through polyfilled. Thus polyfilled would have a lower thermal impact compared to polycarbonate.

  15. Thermal analysis of building roof assisted with water heater and ...

    Indian Academy of Sciences (India)

    D Prakash

    2018-03-14

    Mar 14, 2018 ... Thermal analysis; building roof; solar water heating system; roof ... These solar collec- ... several benefits, such as its wide range of storage temper- ... rugated plate, rear plate and back insulation material [12]. ..... [7] Weiss W and Rommel M 2008 Process heat collectors. State of the art within Task 33/IV.

  16. Extensive Green Roof Research Program at Colorado State University

    Science.gov (United States)

    In the high elevation, semi-arid climate of Colorado, green roofs have not been scientifically tested. This research examined alternative plant species, media blends, and plant interactions on an existing modular extensive green roof in Denver, Colorado. Six plant species were ev...

  17. Green roof hydrologic performance and modeling: a review.

    Science.gov (United States)

    Li, Yanling; Babcock, Roger W

    2014-01-01

    Green roofs reduce runoff from impervious surfaces in urban development. This paper reviews the technical literature on green roof hydrology. Laboratory experiments and field measurements have shown that green roofs can reduce stormwater runoff volume by 30 to 86%, reduce peak flow rate by 22 to 93% and delay the peak flow by 0 to 30 min and thereby decrease pollution, flooding and erosion during precipitation events. However, the effectiveness can vary substantially due to design characteristics making performance predictions difficult. Evaluation of the most recently published study findings indicates that the major factors affecting green roof hydrology are precipitation volume, precipitation dynamics, antecedent conditions, growth medium, plant species, and roof slope. This paper also evaluates the computer models commonly used to simulate hydrologic processes for green roofs, including stormwater management model, soil water atmosphere and plant, SWMS-2D, HYDRUS, and other models that are shown to be effective for predicting precipitation response and economic benefits. The review findings indicate that green roofs are effective for reduction of runoff volume and peak flow, and delay of peak flow, however, no tool or model is available to predict expected performance for any given anticipated system based on design parameters that directly affect green roof hydrology.

  18. Single-Sided Natural Ventilation through a Velux Roof Window

    DEFF Research Database (Denmark)

    Li, Zhigang; Nielsen, Peter Vilhelm; Fransson, J.

    2004-01-01

    This paper investigates the single-sided natural ventilation through a VELUX centre pivot roof window under natural weather conditions. The aim of the investigation is to develop an empirical formulation for air flow rate through a roof window based on CFD and tracer gas decay measurement methods...

  19. U-value measurements on a roof window

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    This report describes the results of the U-value measurements performed on a roof window. The work is as a part of the development of an ISO/CEN standard measuring procedure for roof windows.The measurements have been performed using the procedures given in ISO 12567 draft version 1998...

  20. Cool metal roofing tested for energy efficiency and sustainability

    Energy Technology Data Exchange (ETDEWEB)

    Miller, W.A.; Desjarlais, A. [Oak Ridge National Laboratory, Oakridge, TN (United States); Parker, D.S. [Florida Solar Energy Center, Cocoa, FL (United States); Kriner, S. [Metal Construction Association, Glenview, IL (United States)

    2004-07-01

    A 3 year field study was conducted in which temperature, heat flow, reflectance and emittance field data were calculated for 12 different painted and unpainted metal roofs exposed to weathering at an outdoor test facility at Oak Ridge National Laboratory in Oakridge, Tennessee. In addition, the Florida Solar Energy Center tested several Habitat for Humanity homes during one summer in Fort Myers, Florida. The objective was to determine how cooling and heating energy loads in a building are affected by the solar reflectance and infrared emittance of metal roofs. The Habitat for Humanities houses had different roofing systems which reduced the attic heat gain. White reflective roofs were shown to reduce cooling energy needs by 18 to 26 per cent and peak demand by 28 to 35 per cent. High solar reflectance and high infrared emittance roofs incur surface temperatures that are about 3 degrees C warmer than the ambient air temperature. A dark absorptive roof exceeds the ambient air temperature by more than 40 degrees C. It hot climates, a high solar reflectance and high infrared emittance roof can reduce the air conditioning load and reduce peak energy demands on the utility. It was concluded that an informed decision of the roof surface properties of reflectance and emittance can significantly reduce energy costs for homeowners and builders in hot climates. 7 refs., 2 tabs., 7 figs.

  1. Strength and stiffness capacity utilisation of timber members in roof ...

    African Journals Online (AJOL)

    C Brand Wessels, Nils-Olaf Petersen. Abstract. The main objective of this study was to determine which property, of the six strength and stiffness properties used in structural timber design, was the most influential in the design of nail-plated roof trusses. Thirty recently completed nail-plated roof truss designs were randomly ...

  2. Calculation of parameters of combined frame and roof bolting

    Science.gov (United States)

    Ivanov, S. I.; Titov, N. V.; Privalov, A. A.; Trunov, I. T.; Sarychev, V. I.

    2017-10-01

    The paper presents the method of calculation of the combined frame and roof bolting. Recommendations on providing joint operation of roof bolting with steel support frames are given. Graphs for determining standard rock movement, as well as for defining proof load on the yielding support, were developed.

  3. 40 CFR 65.44 - External floating roof (EFR).

    Science.gov (United States)

    2010-07-01

    ... they are closed. (iii) Except for automatic bleeder vents, rim space vents, roof drains, and leg... and rim space vents shall be equipped with a gasket. (v) Each roof drain that empties into the stored... shall be designed to extend into the stored liquid and the other end shall extend a minimum vertical...

  4. Structural assessment of roof decking using visual inspection methods

    International Nuclear Information System (INIS)

    Giller, R.A.; McCoy, R.M.; Wagenblast, G.R.

    1993-01-01

    The Hanford Site has approximately 1,100 buildings, some of which date back to the early 1940s. The roof on these buildings provides a weather resisting cover as well as the load resisting structure. Past experience has been that these roof structures may have structural modifications, the weather resisting membrane may have been replaced several times, and the members may experience some type of material degradation. This material degradation has progressed to cause the collapse of some roof deck members. The intent of the Hanford Site Central Engineering roof assessment effort is to provide an expedient structural assessment of the large number of buildings at the Hanford Site. This assessment is made by qualified structural inspectors following the open-quotes Preliminary Assessmentclose quotes procedures given in the American Society of Civil Engineers (ASCE) Standard ASCE 11-90. This roof assessment effort does not provide a total qualification of the roof for the design or in-place loads. This inspection does provide a reasonable estimate of the roof loading capacity to determine if personnel access restrictions are needed. A document search and a visual walkdown inspection provide the initial screening to identify modifications and components having questionable structural integrity. The structural assessment consists of baseline dead and live load stress calculations of all roofing components based on original design material strengths. The results of these assessments are documented in a final report which is retrievable in a form that future inspections will have comparative information

  5. A new design for luminescent solar concentrating PV roof tiles

    NARCIS (Netherlands)

    Doudart de la Gree, G.C.H.; Papadopoulos, A.; Debije, M.G.; Cox, M.G.D.M.; Krumer, Z.; Reinders, A.H.M.E.; Rosemann, A.L.P.

    2015-01-01

    In our paper we explore the opportunity of combining luminescent solar concentrating (LSC) materials and crystalline PV solar cells in a new design for a roof tile by design-driven research on the energy performance of various configurations of the LSC PV device and on the aesthetic appeal in a roof

  6. Structural assessment of roof decking using visual inspection methods

    International Nuclear Information System (INIS)

    Giller, R.A.; McCoy, R.M.; Wagenblast, G.R.

    1993-10-01

    The Hanford Site has approximately 1,100 buildings, some of which date back to the early 1940s. The roof on these buildings provides a weather resisting cover as well as the load resisting structure. Past experience has been that these roof structures may have structural modifications, the weather resisting membrane may have been replaced several times, and the members may experience some type of material degradation. This material degradation has progressed to cause the collapse of some roof deck members. The intent of the Hanford Site Central Engineering roof assessment effort is to provide an expedient structural assessment of the large number of buildings at the Hanford Site. This assessment is made by qualified structural inspectors following the open-quotes Preliminary Assessment close-quote procedures given in the American Society of Civil Engineers (ASCE) Standard ASCE 11-90. This roof assessment effort does not provide a total qualification of the roof for the design or in-place loads. This inspection does provide a reasonable estimate of the roof loading capacity to determine if personnel access restrictions are needed. A document search and a visual walkdown inspection provide the initial screening to identify modifications and components having questionable structural integrity. The structural assessment consists of baseline dead and live load stress calculations of all roofing components based on original design material strengths. The results of these assessments are documented in a final report which is retrievable form that future inspections will have comparative information

  7. Design strategies for integration of green roofs in sustainable housing

    Directory of Open Access Journals (Sweden)

    Avi Friedman

    2015-12-01

    Full Text Available Green roofs are the integration of plant material and its supporting structures in buildings. Such an approach provides a habitat for local flora and fauna, helps manage storm water, reduces heat demand in winter and the cooling load in the summer, enhances the aesthetic values of dwellings, provides the occupants with comfort and amenities and strengthens environmental responsibility. Because roofs represent approximately 40 percent to 50 percent of the surfaces in urban areas, green roofs have an important role in drainage and as a result water management as well. In fact, when a green roof is installed on 50 percent or more of the roof’s surface, it guarantees 2 points and can contribute 7 additional points toward LEED certification - almost 20 percent of the required rating. This paper classifies green roofs and offers strategies for their integration in residential buildings and examines their benefits, construction principles and applications.

  8. Experimental analysis of green roof substrate detention characteristics.

    Science.gov (United States)

    Yio, Marcus H N; Stovin, Virginia; Werdin, Jörg; Vesuviano, Gianni

    2013-01-01

    Green roofs may make an important contribution to urban stormwater management. Rainfall-runoff models are required to evaluate green roof responses to specific rainfall inputs. The roof's hydrological response is a function of its configuration, with the substrate - or growing media - providing both retention and detention of rainfall. The objective of the research described here is to quantify the detention effects due to green roof substrates, and to propose a suitable hydrological modelling approach. Laboratory results from experimental detention tests on green roof substrates are presented. It is shown that detention increases with substrate depth and as a result of increasing substrate organic content. Model structures based on reservoir routing are evaluated, and it is found that a one-parameter reservoir routing model coupled with a parameter that describes the delay to start of runoff best fits the observed data. Preliminary findings support the hypothesis that the reservoir routing parameter values can be defined from the substrate's physical characteristics.

  9. Software for roof defects recognition on aerial photographs

    Science.gov (United States)

    Yudin, D.; Naumov, A.; Dolzhenko, A.; Patrakova, E.

    2018-05-01

    The article presents information on software for roof defects recognition on aerial photographs, made with air drones. An areal image segmentation mechanism is described. It allows detecting roof defects – unsmoothness that causes water stagnation after rain. It is shown that HSV-transformation approach allows quick detection of stagnation areas, their size and perimeters, but is sensitive to shadows and changes of the roofing-types. Deep Fully Convolutional Network software solution eliminates this drawback. The tested data set consists of the roofing photos with defects and binary masks for them. FCN approach gave acceptable results of image segmentation in Dice metric average value. This software can be used in inspection automation of roof conditions in the production sector and housing and utilities infrastructure.

  10. Mobilization and distribution of lead originating from roof dust and wet deposition in a roof runoff system.

    Science.gov (United States)

    Yu, Jianghua; Yu, Haixia; Huang, Xiaogu

    2015-12-01

    In this research, the mobilization and distribution of lead originating in roof dust and wet deposition were investigated within a roof dust-rooftop-runoff system. The results indicated that lead from roof dust and wet deposition showed different transport dynamics in runoff system and that this process was significantly influenced by the rainfall intensity. Lead present in the roof dust could be easily washed off into the runoff, and nearly 60 % of the total lead content was present in particulate form. Most of the lead from the roof dust was transported during the late period of rainfall; however, the lead concentration was higher for several minutes at the rainfall beginning. Even though some of the lead from wet deposition, simulated with a standard isotope substance, was adsorbed onto adhered roof dust and/or retained on rooftop in runoff system, most of it (50-82 %) remained as dissolved lead in the runoff for rainfall events of varying intensity. Regarding the distribution of lead in the runoff system, the results indicated that it could be carried in the runoff in dissolved and particulate form, be adsorbed to adhered roof dust, or remain on the rooftop because of adsorption to the roof material. Lead from the different sources showed different distribution patterns that were also related to the rainfall intensity. Higher rainfall intensity resulted in a higher proportion of lead in the runoff and a lower proportion of lead remaining on the rooftop.

  11. Entire cities could benefit from green roofs : Heleen Mees is investigating how five metropolises are greenifying their roofs

    NARCIS (Netherlands)

    Mees, Heleen

    Rotterdam is making good progress with its creation of green roofs. Heleen Mees, researcher at Utrecht University, drew this conclusion from her research, in which she compared the green roof policy of four different cities with that of Rotterdam. Rotterdam awards grants to those wishing to create a

  12. Analysis of the impact of thermal resistance of the roof on the performance of photovoltaic roof tiles

    Directory of Open Access Journals (Sweden)

    Kurz Dariusz

    2017-01-01

    Full Text Available The paper explores the issues related to the impact of thermal resistance of the roof on the electrical parameters of photovoltaic roof tiles. The methodology of determination of the thermal resistance and thermal transmittance factor was presented in accordance with the applicable legal regulations and standards. A test station was presented for the purpose of measurement of the parameters of photovoltaic roof tiles depending on the structure of the roof substrate. Detailed analysis of selected building components as well as their impact on the design thermal resistance factor and thermal transmittance factor was carried out. Results of our own studies, which indicated a relation between the type of the roof structure and the values of the electricity generated by photovoltaic tiles, were presented. Based on the calculations, it was concluded that the generated outputs in the respective constructions differ by maximum 6%. For cells with the highest temperature, the performance of the PV roof tiles on the respective roof constructions fell within the range between 0.4% and 1.2% (depending on the conducted measurement and amounted to 8.76% (in reference to 9.97% for roof tiles with the lowest temperature.

  13. The energy efficiency and environmental impacts in the ceramic industry: the case of ceramic coatings segment; A eficiencia energetica e os impactos na industria ceramica: o caso do segmento de revestimentos ceramicos

    Energy Technology Data Exchange (ETDEWEB)

    Berni, Mauro Donizeti [Universidade Estadual de Campinas (NIPE/UNICAMP), SP (Brazil). Nucleo Interdisciplinar de Planejamento Energetico], email: mauro_berni@yahoo.com.br; Bajay, Sergio Valdir [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Fac. de Engenharia Mecanica. Dept. de Energia

    2010-07-01

    The Brazilian ceramic industry has great importance for the country, with a stake of more than 1.0% of GDP, or approximately $ 6 billion. The segment of ceramic coatings due to the higher revenues, production, employment, value of manufacturing and penetration in foreign markets, has been the highlight of the ceramic sector. Besides most representative in economic terms, the ceramic coatings segment presents with the largest final energy consumption and volume of emissions. This work shows the evolution of the final energy consumption of the ceramic sector, showing that the segment of ceramic coatings can be successful harnessing of potential energy conservation with reflections on the mitigation of greenhouse gas emissions. Therefore, the study evaluates: the process and energy sources; reducing impacts along the entire life cycle of products and the management actions providing a new corporate culture and social and environmental responsibility.

  14. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    Energy Technology Data Exchange (ETDEWEB)

    Syd S. Peng

    2005-04-15

    In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The main accomplishments in this quarter included: (1) one more field test has been conducted in an underground coal mine, (2) optimization studies of the control parameters have been conducted, (3) the relationship among feed pressure, penetration rate and rotation rate seems to be a good indicator for estimating rock strength when both penetration rate and rotation rate are controlled or kept constant, (4) the empirical equations for eliminating the machine effect on drilling parameters were developed and verified, and (5) a real time roof geology mapping system for roof bolters in limestone mine, including a special version of the geology mapping program and hardware, performs very well in underground production condition.

  15. Cool roofs and the influence on the energy consumption under Danish conditions

    DEFF Research Database (Denmark)

    Brandt, Erik; Bunch-Nielsen, Tommy; Juhl, Lasse

    Experience from countries in warm climates has shown that the color of the roofing material has a significant effect on the energy consumption of the building. Especially changing from black to white roofing material provides reduction in energy consumption. The investigated roofs have been...... with a moderate amount of thermal insulation. The Danish Roofing Advisory Board in Denmark has conducted an analysis of the effects of roofing color on buildings energy consumption under Danish conditions i.e. with a colder climate and with a larger amount of thermal insulation. An experiment was performed...... in order to study the effects of the roofing color on the temperature distribution in a roof structure. The studied roof specimens were flat roofs covered with roofing felt in different colors. Temperatures have been measured in the roofing felt as well as in the middle and the bottom of the structure...

  16. Stormwater quality from extensive green roofs in a subtropical region

    Science.gov (United States)

    Onis Pessoa, Jonas; Allasia, Daniel; Tassi, Rutineia; Vaz Viega, Juliana; Fensterseifer, Paula

    2016-04-01

    Green roofs have increasingly become an integral part of urban environments, mainly due to their aesthetic benefits, thermal comfort and efficiency in controlling excess runoff. However, the effects of this emerging technology in the qualitative characteristics of rainwater is still poorly understood. In this study was evaluated the effect of two different extensive green roofs (EGRs) and a traditional roof built with corrugated fiber cement sheets (control roof) in the quality of rainwater, in a subtropical climate area in the city of Santa Maria, in southern Brazil. The principal variant between the two EGRs were the type of plant species, time since construction, soil depth and the substrate characteristics. During the monitoring period of the experiment, between the months of April and December of 2015 fourteen rainfall events were selected for qualitative analysis of water from the three roofs and directly from rainfall. It was analyzed physical (turbidity, apparent color, true color, electrical conductivity, total solids, dissolved solids, suspended solids and temperature), chemical (pH, phosphate, total nitrogen, nitrate, nitrite, chloride, sulfate, BOD, iron and total hardness), heavy metals (copper, zinc, lead and chromium) and microbiological parameters (total coliforms and E. coli). It was also characterized the substrates used in both extensive green roofs. The results showed that the quality of the water drained from EGR s was directly influenced by their substrates (in turn containing significant levels of nutrients, organic matter and some metals). The passage of rainwater through green roofs and control roof resulted in the elevation of pH, allowing the conversion of the slightly acidic rainfall into basic water. Similarly, on both types of roofs occurred an increase of the values of most of the physical, chemical and microbiological parameters compared to rainwater. This same trend was observed for heavy metals, although with a much smaller degree

  17. Numerical analysis on thermal performance of roof contained PCM of a single residential building

    International Nuclear Information System (INIS)

    Li, Dong; Zheng, Yumeng; Liu, Changyu; Wu, Guozhong

    2015-01-01

    Highlights: • Thermal performance of different roofs in cold area of China are investigated. • Effects of five different conditions on thermal performance of roofs are analyzed. • Delay time of temperatures peak in PCM roofs are beyond 3 h than common roof. - Abstract: The phase change material (PCM) applied in the roof can decrease the building energy consumption and improve the thermal comfort by enhancing the thermal energy storage capacity of building envelope. In the present work, the thermal performance of different kinds of roofs with and without PCM in Northeast and cold area of China, i.e. common roof and PCM roofs, have been investigated numerically. This study also explored the influencing factors of thermal behavior of the roofs, such as solar radiation intensity, transition temperature and latent heat of PCM, roof slope, PCM layer thickness, and absorption coefficients of external roof surface. The results show that the PCM roofs effect on the temperature delay in the room is very strong and the delay time of temperatures peak of base layer in PCM roofs are beyond 3 h than common roof. The effect of transition temperature and latent heat of PCM on the thermal performance of roofs is relatively weak, compared with the roof slope, PCM layer thickness and absorption coefficients of external roof surface

  18. Soiling of building envelope surfaces and its effect on solar reflectance – Part II: Development of an accelerated aging method for roofing materials

    Energy Technology Data Exchange (ETDEWEB)

    Sleiman, Mohamad [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kirchstetter, Thomas W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Berkeley, CA (United States); Berdahl, Paul [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gilbert, Haley E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Quelen, Sarah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Marlot, Lea [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Preble, Chelsea V. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Berkeley, CA (United States); Chen, Sharon [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Montalbano, Amandine [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Rosseler, Olivier [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Akbari, Hashem [Concordia Univ., Montreal (Canada); Levinson, Ronnen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Destaillats, Hugo [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-09

    Highly reflective roofs can decrease the energy required for building air conditioning, help mitigate the urban heat island effect, and slow global warming. However, these benefits are diminished by soiling and weathering processes that reduce the solar reflectance of most roofing materials. Soiling results from the deposition of atmospheric particulate matter and the growth of microorganisms, each of which absorb sunlight. Weathering of materials occurs with exposure to water, sunlight, and high temperatures. This study developed an accelerated aging method that incorporates features of soiling and weathering. The method sprays a calibrated aqueous soiling mixture of dust minerals, black carbon, humic acid, and salts onto preconditioned coupons of roofing materials, then subjects the soiled coupons to cycles of ultraviolet radiation, heat and water in a commercial weatherometer. Three soiling mixtures were optimized to reproduce the site-specific solar spectral reflectance features of roofing products exposed for 3 years in a hot and humid climate (Miami, Florida); a hot and dry climate (Phoenix, Arizona); and a polluted atmosphere in a temperate climate (Cleveland, Ohio). A fourth mixture was designed to reproduce the three-site average values of solar reflectance and thermal emittance attained after 3 years of natural exposure, which the Cool Roof Rating Council (CRRC) uses to rate roofing products sold in the US. This accelerated aging method was applied to 25 products₋single ply membranes, factory and field applied coatings, tiles, modified bitumen cap sheets, and asphalt shingles₋and reproduced in 3 days the CRRC's 3-year aged values of solar reflectance. In conclusion, this accelerated aging method can be used to speed the evaluation and rating of new cool roofing materials.

  19. Comparison of a burning mass ceramics coating in laboratory furnace and instrustrial furnace; Comparacao de queimas de uma massa ceramica de revestimento em forno de laboratorio e forno industrial

    Energy Technology Data Exchange (ETDEWEB)

    Soares, R.A.L., E-mail: robertoarruda@ifpi.edu.br [Instituto Federal de Educacao, Ciencia e Tecnologia do Piaui (IFPI), Terersina, PI (Brazil); Castro, J.R. de S. [Universidade Federal do Piaui (UFPI), Teresina, PI (Brazil)

    2012-07-01

    This work intends to analyze the differences obtained in the technological properties of a ceramic coating after firing in two distinct environments, laboratory furnace and industrial furnace. For this, was characterized a ceramic mass used in the production of porous coating. The analyzes were performed chemical, mineralogical and thermal mass in that. The specimens were obtained by compacting and burned in the maximum temperature of 1140 deg C in two furnaces, laboratory and industrial. The technological tests were performed linear shrinkage, water absorption, bulk density and mechanical strength. The microstructure was evaluated by ray-X diffraction and scanning electron microscopy. The results showed that both furnaces provided significant differences in analyzed specimens, such as increased strength and low water absorption in the fired samples in a laboratory furnace, for example. (author)

  20. Typology of Retractable Roof Structures in Stadiums and Sports Halls

    Directory of Open Access Journals (Sweden)

    Andrej Mahovič

    2015-10-01

    Full Text Available Retractable roof structures are one of the four fundamental systems (in addition to the playing area, stands and facade in a stadium and sports hall. The roof protects users against various weather conditions and creates optimum circumstances for carrying out different activities. Stadiums and sports halls with retractable roof structures can host a greater variety of activities, improve the quality of their implementation and the quality of visitors’ experience, and affect the perception and experience of people using or observing such buildings. A retractable roof structure allows for natural lighting and ventilation of the venue, gives optimal conditions for grass growth on the playing field, and reduces costs of use and maintenance of the building. Different typologies of movement of roof structures (frequency of opening and closing, design of the structure, and methods of movement are categorised in terms of their architectural and structural design. Application of different retractable roof systems worldwide is indicator of their effectiveness and efficiency, and is basis for use of movement also in other fundamental systems of stadiums and sports halls. Research and identification of characteristics of retractable roof structures lead to the design of new moving systems that can with the application of the moving principle change the purpose of movable elements or assume the characteristics of other fundamental systems.

  1. Roof Moisture Surveys: Current State Of The Technology

    Science.gov (United States)

    Tobiasson, Wayne

    1983-03-01

    Moisture is the big enemy of compact roofing systems. Non-destructive nuclear, capacitance and infrared methods can all find wet insulation in such roofs but a few core samples are needed for verification. Nuclear and capacitance surveys generate quantitative results at grid points but examine only a small portion of the roof. Quantitative results are not usually provided by infrared scanners but they can rapidly examine every square inch of the roof. Being able to find wet areas when they are small is an important advantage. Prices vary with the scope of the investigation. For a particular scope, the three techniques are often cost-competitive. The limitations of each technique are related to the people involved as well as the equipment. When the right people are involved, non-destructive surveys are a very effective method for improving the long-term performance and reducing the life-cycle costs of roofing systems. Plans for the maintenance, repair or replacement of a roof should include a roof moisture survey.

  2. Multi functional roof structures of the energy efficient buildings

    Directory of Open Access Journals (Sweden)

    Krstić Aleksandra

    2006-01-01

    Full Text Available Modern architectural concepts, which are based on rational energy consumption of buildings and the use of solar energy as a renewable energy source, give the new and significant role to the roofs that become multifunctional structures. Various energy efficient roof structures and elements, beside the role of protection, provide thermal and electric energy supply, natural ventilation and cooling of a building, natural lighting of the indoor space sunbeam protection, water supply for technical use, thus according to the above mentioned functions, classification and analysis of such roof structures and elements are made in this paper. The search for new architectural values and optimization in total energy balance of a building or the likewise for the urban complex, gave to roofs the role of "climatic membranes". Contemporary roof forms and materials clearly exemplify their multifunctional features. There are numerous possibilities to achieve the new and attractive roof design which broadens to the whole construction. With such inducement, this paper principally analyze the configuration characteristics of the energy efficient roof structures and elements, as well as the visual effects that may be achieved by their application.

  3. A field study to evaluate runoff quality from green roofs.

    Science.gov (United States)

    Vijayaraghavan, K; Joshi, U M; Balasubramanian, R

    2012-03-15

    Green (vegetated) roofs are emerging as practical strategies to improve the environmental quality of cities. However, the impact of green roofs on the storm water quality remains a topic of concern to city planners and environmental policy makers. This study investigated whether green roofs act as a source or a sink of various metals (Na, K, Ca, Mg, Al, Fe, Cu, Cd, Pb, Zn, Mn, Cr, Ni, Li and Co), inorganic anions (NO3-, NO2-, PO4(3-), SO4(2-), Cl-, F- and Br-) and cation (NH4+). A series of green roof assemblies were constructed. Four different real rain events and several artificial rain events were considered for the study. Results showed that concentrations of most of the chemical components in runoff were highest during the beginning of rain events and subsided in the subsequent rain events. Some of the important components present in the runoff include Na, K, Ca, Mg, Li, Fe, Al, Cu, NO3-, PO4(3-) and SO4(2-). However, the concentration of these chemical components in the roof runoff strongly depends on the nature of substrates used in the green roof and the volume of rain. Based on the USEPA standards for freshwater quality, we conclude that the green roof used in this study is reasonably effective except that the runoff contains significant amounts of NO3- and PO4(3-). Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Comparative life cycle assessment of standard and green roofs.

    Science.gov (United States)

    Saiz, Susana; Kennedy, Christopher; Bass, Brad; Pressnail, Kim

    2006-07-01

    Life cycle assessment (LCA) is used to evaluate the benefits, primarily from reduced energy consumption, resulting from the addition of a green roof to an eight story residential building in Madrid. Building energy use is simulated and a bottom-up LCA is conducted assuming a 50 year building life. The key property of a green roof is its low solar absorptance, which causes lower surface temperature, thereby reducing the heat flux through the roof. Savings in annual energy use are just over 1%, but summer cooling load is reduced by over 6% and reductions in peak hour cooling load in the upper floors reach 25%. By replacing the common flat roof with a green roof, environmental impacts are reduced by between 1.0 and 5.3%. Similar reductions might be achieved by using a white roof with additional insulation for winter, but more substantial reductions are achieved if common use of green roofs leads to reductions in the urban heat island.

  5. Chemical composition of water from roofs in Gdansk, Poland

    International Nuclear Information System (INIS)

    Tsakovski, Stefan; Tobiszewski, Marek; Simeonov, Vasil; Polkowska, Zaneta; Namiesnik, Jacek

    2010-01-01

    This study deals with the assessment of roof runoff waters from the region of Gdansk collected during the winter season (2007/2008). The chemical analysis includes 16 chemical variables: major ions, PAHs and PCBs measured at 3 sampling sites for 6-14 rain events. Although the data set is of limited volume the statistical data treatment using self-organizing maps (SOM) reveals the main factors controlling roof runoff water quality even for a data set with small dimension. This effort for explanation of the identified factors by the possible emission sources of the urban environment and air-particulate formation seems to be very reliable. Additionally to the roof runoff water quality factors the rain events patterns are found: 'background' group of events and groups formally named 'PAHs', 'PCBs' and 'air-borne particles' - dominated events. The SOM classification results give an opportunity to uncover the role of roof 'impact' on the runoff waters. Rain runoff water quality is described by four latent factors and the 'roof' impact is uncovered. - Identification of the urban roof runoff water quality factors and 'roof' impact by self-organizing map classification.

  6. Rainwater runoff retention on an aged intensive green roof.

    Science.gov (United States)

    Speak, A F; Rothwell, J J; Lindley, S J; Smith, C L

    2013-09-01

    Urban areas are characterised by large proportions of impervious surfaces which increases rainwater runoff and the potential for surface water flooding. Increased precipitation is predicted under current climate change projections, which will put further pressure on urban populations and infrastructure. Roof greening can be used within flood mitigation schemes to restore the urban hydrological balance of cities. Intensive green roofs, with their deeper substrates and higher plant biomass, are able to retain greater quantities of runoff, and there is a need for more studies on this less common type of green roof which also investigate the effect of factors such as age and vegetation composition. Runoff quantities from an aged intensive green roof in Manchester, UK, were analysed for 69 rainfall events, and compared to those on an adjacent paved roof. Average retention was 65.7% on the green roof and 33.6% on the bare roof. A comprehensive soil classification revealed the substrate, a mineral soil, to be in good general condition and also high in organic matter content which can increase the water holding capacity of soils. Large variation in the retention data made the use of predictive regression models unfeasible. This variation arose from complex interactions between Antecedant Dry Weather Period (ADWP), season, monthly weather trends, and rainfall duration, quantity and peak intensity. However, significantly lower retention was seen for high rainfall events, and in autumn, which had above average rainfall. The study period only covers one unusually wet year, so a longer study may uncover relationships to factors which can be applied to intensive roofs elsewhere. Annual rainfall retention for Manchester city centre could be increased by 2.3% by a 10% increase in intensive green roof construction. The results of this study will be of particular interest to practitioners implementing greenspace adaptation in temperate and cool maritime climates. Copyright © 2013

  7. Case studies of green roof policy from Canada

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, S. [Canada Mortgage and Housing Corp., Ottawa, ON (Canada)

    2006-07-01

    In order to overcome environmental, economic, and social challenges, such as stormwater management, heat island effects, reducing energy use in buildings and increasing amenity space, green roof technology has been a key approach used in many European countries and is gaining acceptance throughout North America as knowledge of the environmental benefits and green roof technology grows. While the conditions, benefits and market forces that have driven green roof development in Europe are not identical to Canada's, lessons can be learned from their experiences. Canadian municipalities that are looking to develop and implement green roof policies and programs will need information on how to tailor policies and programs for specific climate conditions, environmental concerns and regulatory realities. In order to provide Canadian municipal decision-makers with an overview of international and local green roof policies and programs, a green roof policy infrastructure manual was recently completed for the Canada Mortgage and Housing Corporation. Decision-makers can be better informed about which policies may be best suited to meet their specific policy needs by reviewing the motivators and other factors behind existing programs around the world. The manual describes green roof policies in each of 12 different jurisdictions from Canada, the United States, Germany, Switzerland, Singapore, and Japan in terms of local green roof motivators and the steps taken along the continuum of establishing policy. This paper described the progress of some Canadian cities that are moving through six phases of establishing appropriate green roof policies and programs. The six phases were introductory and awareness; community engagement; action plan development and implementation; technical research; program and policy development and continuous improvement.

  8. Formulation and in vitro and in vivo evaluation of film-coated montelukast sodium tablets using Opadry® yellow 20A82938 on an industrial scale

    Directory of Open Access Journals (Sweden)

    Zaid AN

    2013-02-01

    Full Text Available Abdel Naser Zaid,1 Salam Natur,2 Aiman Qaddumi,2 Abeer Abu Ghoush11Department of Pharmacy, Faculty of Medicine and Health Sciences, An-Najah National University, Nablus, Palestine; 2Pharmacare PLC, Ramallah, PalestinePurpose: The aim of this study was to formulate stable film-coated montelukast sodium (MS tablets using Opadry® yellow 20A82938 (Montikast® tablets and to evaluate their in vitro and in vivo release profile.Methods: MS core tablets were manufactured using a direct compression method. Opadry yellow 20A82938 aqueous coating dispersion was used as the film-coating material. Dissolution of the film-coated tablets was tested in 900 mL of 0.5% sodium lauryl sulfate solution and the bioequivalence of the tablets was tested by comparing them with a reference formulation – Singulair® tablets. In vitro–in vivo correlation was evaluated. The stability of the obtained film-coated tablets was evaluated according to International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use guidelines.Results: The efficiency of the film coating was determined by subjecting the coated tablets to gastric pH and drug release was analyzed using high-performance liquid chromatography. The coated tablets had no obvious defects. MS release met the study criterion of not less than 80% dissolved after 30 minutes in 0.5% sodium lauryl sulfate solution. Statistical comparison of the main pharmacokinetic parameters clearly indicated no significant difference between test and reference in any of the calculated pharmacokinetic parameters. Level A correlation between in vitro drug release and in vivo absorption was found to be satisfactory.Conclusion: These findings suggest that aqueous film coating with Opadry yellow 20A82938 is an easy, reproducible, and economical approach for preparing stable MS film-coated tablets without affecting the drug-release characteristics.Keywords: coating, stability, aqueous

  9. Automatic Generation of 3D Building Models with Multiple Roofs

    Institute of Scientific and Technical Information of China (English)

    Kenichi Sugihara; Yoshitugu Hayashi

    2008-01-01

    Based on building footprints (building polygons) on digital maps, we are proposing the GIS and CG integrated system that automatically generates 3D building models with multiple roofs. Most building polygons' edges meet at right angles (orthogonal polygon). The integrated system partitions orthogonal building polygons into a set of rectangles and places rectangular roofs and box-shaped building bodies on these rectangles. In order to partition an orthogonal polygon, we proposed a useful polygon expression in deciding from which vertex a dividing line is drawn. In this paper, we propose a new scheme for partitioning building polygons and show the process of creating 3D roof models.

  10. Effects of Solar Photovoltaic Panels on Roof Heat Transfer

    Science.gov (United States)

    Dominguez, A.; Klessl, J.; Samady, M.; Luvall, J. C.

    2010-01-01

    Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than

  11. The impact of roofing material on building energy performance

    Science.gov (United States)

    Badiee, Ali

    The last decade has seen an increase in the efficient use of energy sources such as water, electricity, and natural gas as well as a variety of roofing materials, in the heating and cooling of both residential and commercial infrastructure. Oil costs, coal and natural gas prices remain high and unstable. All of these instabilities and increased costs have resulted in higher heating and cooling costs, and engineers are making an effort to keep them under control by using energy efficient building materials. The building envelope (that which separates the indoor and outdoor environments of a building) plays a significant role in the rate of building energy consumption. An appropriate architectural design of a building envelope can considerably lower the energy consumption during hot summers and cold winters, resulting in reduced HVAC loads. Several building components (walls, roofs, fenestration, foundations, thermal insulation, external shading devices, thermal mass, etc.) make up this essential part of a building. However, thermal insulation of a building's rooftop is the most essential part of a building envelope in that it reduces the incoming "heat flux" (defined as the amount of heat transferred per unit area per unit time from or to a surface) (Sadineni et al., 2011). Moreover, more than 60% of heat transfer occurs through the roof regardless of weather, since a roof is often the building surface that receives the largest amount of solar radiation per square annually (Suman, and Srivastava, 2009). Hence, an argument can be made that the emphasis on building energy efficiency has influenced roofing manufacturing more than any other building envelope component. This research project will address roofing energy performance as the source of nearly 60% of the building heat transfer (Suman, and Srivastava, 2009). We will also rank different roofing materials in terms of their energy performance. Other parts of the building envelope such as walls, foundation

  12. Can green roof act as a sink for contaminants? A methodological study to evaluate runoff quality from green roofs.

    Science.gov (United States)

    Vijayaraghavan, K; Joshi, Umid Man

    2014-11-01

    The present study examines whether green roofs act as a sink or source of contaminants based on various physico-chemical parameters (pH, conductivity and total dissolved solids) and metals (Na, K, Ca, Mg, Al, Fe, Cr, Cu, Ni, Zn, Cd and Pb). The performance of green roof substrate prepared using perlite, vermiculite, sand, crushed brick, and coco-peat, was compared with local garden soil based on improvement of runoff quality. Portulaca grandiflora was used as green roof vegetation. Four different green roof configurations, with vegetated and non-vegetated systems, were examined for several artificial rain events (un-spiked and metal-spiked). In general, the vegetated green roof assemblies generated better-quality runoff with less conductivity and total metal ion concentration compared to un-vegetated assemblies. Of the different green roof configurations examined, P. grandiflora planted on green roof substrate acted as sink for various metals and showed the potential to generate better runoff. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. An environmental cost-benefit analysis of alternative green roofing strategies

    Science.gov (United States)

    Richardson, M.; William, R. K.; Goodwell, A. E.; Le, P. V.; Kumar, P.; Stillwell, A. S.

    2016-12-01

    Green roofs and cool roofs are alternative roofing strategies that mitigate urban heat island effects and improve building energy performance. Green roofs consist of soil and vegetation layers that provide runoff reduction, thermal insulation, and potential natural habitat, but can require regular maintenance. Cool roofs involve a reflective layer that reflects more sunlight than traditional roofing materials, but require additional insulation during winter months. This study evaluates several roofing strategies in terms of energy performance, urban heat island mitigation, water consumption, and economic cost. We use MLCan, a multi-layer canopy model, to simulate irrigated and non-irrigated green roof cases with shallow and deep soil depths during the spring and early summer of 2012, a drought period in central Illinois. Due to the dry conditions studied, periodic irrigation is implemented in the model to evaluate its effect on evapotranspiration. We simulate traditional and cool roof scenarios by altering surface albedo and omitting vegetation and soil layers. We find that both green roofs and cool roofs significantly reduce surface temperature compared to the traditional roof simulation. Cool roof temperatures always remain below air temperature and, similar to traditional roofs, require low maintenance. Green roofs remain close to air temperature and also provide thermal insulation, runoff reduction, and carbon uptake, but might require irrigation during dry periods. Due to the longer lifetime of a green roof compared to cool and traditional roofs, we find that green roofs realize the highest long term cost savings under simulated conditions. However, using longer-life traditional roof materials (which have a higher upfront cost) can help decrease this price differential, making cool roofs the most affordable option due to the higher maintenance costs associated with green roofs

  14. Air formaldehyde and solvent concentrations during surface coating with acid-curing lacquers and paints in the woodworking and furniture industry.

    Science.gov (United States)

    Thorud, Syvert; Gjolstad, Merete; Ellingsen, Dag G; Molander, Paal

    2005-06-01

    An investigation of contemporary exposure to formaldehyde and organic solvents has been carried out during surface coating with acid-curing lacquers and paints in the Norwegian woodworking and furniture industry over a period of 3 years. The investigation covered 27 factories of different sizes and with different types of production, and totally 557 parallel formaldehyde and solvent samples were collected. The formaldehyde concentration (geometric mean) was 0.15 ppm (range 0.01-1.48 ppm) with about 10% of the samples exceeding the Norwegian occupational exposure limit of 0.5 ppm. The solvent concentration as additive effect (geometric mean) was 0.13 (range 0.0004-5.08) and about 5% of the samples exceeded the Norwegian occupational exposure limit. The most frequently occurring solvents from acid-curing lacquers were n-butyl acetate, ethanol, ethyl acetate and 1-butanol, which were found in 88-98% of the samples. Toluene, n-butyl acetate and 1-butanol were the only solvents with maximum concentrations exceeding their respective occupational exposure limits. Curtain painting machine operators were exposed to the highest concentrations of both formaldehyde (geometric mean 0.51 ppm, range 0.08-1.48 ppm) and organic solvents (additive effect, geometric mean 1.18, range 0.02-5.08). Other painting application work tasks such as automatic and manual spray-painting, manual painting and dip painting, showed on average considerably lower concentrations of both formaldehyde (geometric means 0.07-0.16 ppm) and organic solvents (additive effect, geometric mean 0.02-0.18). Non-painting work tasks also displayed moderate concentrations of formaldehyde (geometric means 0.11-0.17 ppm) and organic solvents (additive effect, geometric mean 0.04-0.07).

  15. Final Report for completed IPP-0110 and 0110A Projects: 'High Energy Ion Technology of Interfacial Thin Film Coatings for Electronic, Optical and Industrial Applications'

    International Nuclear Information System (INIS)

    Brown, Ian

    2009-01-01

    The DOE-supported IPP (Initiatives for Proliferation Prevention) Project, IPP-0110, and its accompanying 'add-on project' IPP-0110A, entitled 'High Energy Ion Technology of Interfacial Thin Film Coatings for Electronic, Optical and Industrial Applications' was a collaborative project involving the Lawrence Berkeley National Laboratory (LBNL) as the U.S. DOE lab; the US surface modification company, Phygen, Inc., as the US private company involved; and the High Current Electronics Institute (HCEI) of the Russian Academy of Sciences, Tomsk, Siberia, Russia, as the NIS Institute involved. Regular scientific research progress meetings were held to which personnel came from all participating partners. The meetings were held mostly at the Phygen facilities in Minneapolis, Minnesota (with Phygen as host) with meetings also held at Tomsk, Russia (HCEI as host), and at Berkeley, California (LBNL as host) In this way, good exposure of all researchers to the various different laboratories involved was attained. This report contains the Final Reports (final deliverables) from the Russian Institute, HCEI. The first part is that for IPP-0110A (the 'main part' of the overall project) and the second part is that for the add-on project IPP-0110A. These reports are detailed, and contain all aspects of all the research carried out. The project was successful in that all deliverables as specified in the proposals were successfully developed, tested, and delivered to Phygen. All of the plasma hardware was designed, made and tested at HCEI, and the performance was excellent. Some of the machine and performance parameters were certainly of 'world class'. The goals and requirements of the IPP Project were well satisfied. I would like to express my gratitude to the DOE IPP program for support of this project throughout its entire duration, and for the unparalleled opportunity thereby provided for all of the diverse participants in the project to join in this collaborative research. The

  16. Application Of Fractal Dimension On Atmospheric Corrosion Of Galvanized Iron Roofing Material

    OpenAIRE

    Issa A.K; Abba. M. Aji

    2015-01-01

    Abstract Corrosion rates of galvanized iron roofing sheet In yola north eastern part of Nigeria were assessed and determined by weight loss method and scanner fractal analysis method. Scanning electronic machine SEM was used to transform corrosion coupons to electronic form for image j processing and analysing software The result of corrosion rates for these two methods after six months of the samples exposure in industrial. Coastal market and urban areas in the region are 1.51 1.079 1.051 0....

  17. A novel technique for the production of cool colored concrete tile and asphalt shingle roofing products

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, Ronnen; Akbari, Hashem; Berdahl, Paul [Heat Island Group, Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Wood, Kurt; Skilton, Wayne; Petersheim, Jerry [Arkema, Inc., Philadelphia, PA (United States)

    2010-06-15

    The widespread use of solar-reflective roofing materials can save energy, mitigate urban heat islands and slow global warming by cooling the roughly 20% of the urban surface that is roofed. In this study we created prototype solar-reflective nonwhite concrete tile and asphalt shingle roofing materials using a two-layer spray coating process intended to maximize both solar reflectance and factory-line throughput. Each layer is a thin, quick-drying, pigmented latex paint based on either acrylic or a poly(vinylidene fluoride)/acrylic blend. The first layer is a titanium dioxide rutile white basecoat that increases the solar reflectance of a gray-cement concrete tile from 0.18 to 0.79, and that of a shingle surfaced with bare granules from 0.06 to 0.62. The second layer is a ''cool'' color topcoat with weak near-infrared (NIR) absorption and/or strong NIR backscattering. Each layer dries within seconds, potentially allowing a factory line to pass first under the white spray, then under the color spray. We combined a white basecoat with monocolor topcoats in various shades of red, brown, green and blue to prepare 24 cool colored prototype tiles and 24 cool colored prototypes shingles. The solar reflectances of the tiles ranged from 0.26 (dark brown; CIELAB lightness value L{sup *}=29) to 0.57 (light green; L{sup *}=76); those of the shingles ranged from 0.18 (dark brown; L{sup *}=26) to 0.34 (light green; L{sup *}=68). Over half of the tiles had a solar reflectance of at least 0.40, and over half of the shingles had a solar reflectance of at least 0.25. (author)

  18. Modeling a Hydrologically Optimal Green Roof Media Mixture

    Science.gov (United States)

    Background/Questions/MethodsA key environmental concern in managing urban ecosystems is controlling stormwater runoff to ameliorate pollution problems and sewage overflows. Vegetated green roofs have become an important green infrastructure tool to collect, store, and gradually r...

  19. Diaphragm Effect of Steel Space Roof Systems in Hall Structures

    Directory of Open Access Journals (Sweden)

    Mehmet FENKLİ

    2015-09-01

    Full Text Available Hall structures have been used widely for different purposes. They have are reinforced concrete frames and shear wall with steel space roof systems. Earthquake response of hall structures is different from building type structures. One of the most critical nodes is diaphragm effect of steel space roof on earthquake response of hall structures. Diaphragm effect is depending on lateral stiffness capacity of steel space roof system. Lateral stiffness of steel space roof system is related to modulation geometry, support conditions, selected sections and system geometry. In current paper, three representative models which are commonly used in Turkey were taken in to account for investigation. Results of numerical tests were present comparatively

  20. MODELING OF STORM WATER RUNOFF FROM GREEN ROOFS

    Directory of Open Access Journals (Sweden)

    Ewa Burszta-Adamiak

    2014-10-01

    Full Text Available Apart from direct measurements, modelling of runoff from green roofs is valuable source of information about effectiveness of this type of structure from hydrological point of view. Among different type of models, the most frequently used are numerical models. They allow to assess the impact of green roofs on decrease and attenuation of runoff, reduction of peak runoff and value of water retention. This paper presents preliminary results of research on computing the rate of runoff from green roofs using GARDENIA model. The analysis has been carried out for selected rainfall events registered during measuring campaign on pilot-scale green roofs. Obtained results are promising and show good fit between observed and simulated runoff.

  1. Summer Thermal Performance of Ventilated Roofs with Tiled Coverings

    International Nuclear Information System (INIS)

    Bortoloni, M; Bottarelli, M; Piva, S

    2017-01-01

    The thermal performance of a ventilated pitched roof with tiled coverings is analysed and compared with unventilated roofs. The analysis is carried out by means of a finite element numerical code, by solving both the fluid and thermal problems in steady-state. A whole one-floor building with a pitched roof is schematized as a 2D computational domain including the air-permeability of tiled covering. Realistic data sets for wind, temperature and solar radiation are used to simulate summer conditions at different times of the day. The results demonstrate that the batten space in pitched roofs is an effective solution for reducing the solar heat gain in summer and thus for achieving better indoor comfort conditions. The efficiency of the ventilation is strictly linked to the external wind conditions and to buoyancy forces occurring due to the heating of the tiles. (paper)

  2. Summer Thermal Performance of Ventilated Roofs with Tiled Coverings

    Science.gov (United States)

    Bortoloni, M.; Bottarelli, M.; Piva, S.

    2017-01-01

    The thermal performance of a ventilated pitched roof with tiled coverings is analysed and compared with unventilated roofs. The analysis is carried out by means of a finite element numerical code, by solving both the fluid and thermal problems in steady-state. A whole one-floor building with a pitched roof is schematized as a 2D computational domain including the air-permeability of tiled covering. Realistic data sets for wind, temperature and solar radiation are used to simulate summer conditions at different times of the day. The results demonstrate that the batten space in pitched roofs is an effective solution for reducing the solar heat gain in summer and thus for achieving better indoor comfort conditions. The efficiency of the ventilation is strictly linked to the external wind conditions and to buoyancy forces occurring due to the heating of the tiles.

  3. Comparison of the chemical quality of rainwater harvested from roof ...

    African Journals Online (AJOL)

    2018-04-02

    Apr 2, 2018 ... 4, place Jussieu 75252 Paris Cedex 05, France ... Keywords: rainwater harvesting, roof-harvested rainwater, pollution, human health, food security, ... Received 18 December 2015; accepted in revised form 26 March 2018.

  4. Potential energy savings from cool roofs in Spain and Andalusia

    International Nuclear Information System (INIS)

    Boixo, Sergio; Diaz-Vicente, Marian; Colmenar, Antonio; Castro, Manuel Alonso

    2012-01-01

    Cool roofs are an inexpensive method to save energy and to improve the comfort level in buildings in mild and hot climates. A high scale implementation of cool roofs in Andalusia, in the south of Spain, could potentially save 295,000 kWh per year, considering only residential buildings with flat roofs using electrical heating. At the current energy prices, consumers can save 59 million euros annually in electricity costs and the emission of 136,000 metric tons of CO 2 can be directly avoided every year from the production of that electricity. If radiative forcings are considered, Andalucía can potentially offset between 9.44 and 12 Mt of CO 2 . All the provinces in the rest of Spain are also studied in this paper. The biggest savings are achieved in Gran Canaria (48%), Tenerife (48%), Cádiz (36%), Murcia (33%), Huelva (30%), Málaga (29%), Almería (29%) and Sevilla (28%), where savings are greater than 2 euros per square meter of flat roof for old buildings with dark roofs. For the biggest cities the range of savings obtained are: between 7.4% and 11% in Madrid, between 12% and 18% in Barcelona and between 14% and 20% in Valencia. -- Highlights: ► We estimate potential savings in energy, CO 2 , and money for cool roofs in Spain (residential sector with flat roofs). ► Average savings are of around one euro per square meter in the biggest cities. ► Potential savings are of more than 2 €/m 2 in the hottest cities. ► In Andalusia the potential savings are 300 MWh, 60 millions euro and 136,000 tons of CO 2 per year. ► With forcings, the CO 2 equivalence of cool roofs in Andalusia is between 9 and 12 Mt.

  5. Plant species richness enhances nitrogen retention in green roof plots.

    Science.gov (United States)

    Johnson, Catherine; Schweinhart, Shelbye; Buffam, Ishi

    2016-10-01

    Vegetated (green) roofs have become common in many cities and are projected to continue to increase in coverage, but little is known about the ecological properties of these engineered ecosystems. In this study, we tested the biodiversity-ecosystem function hypothesis using commercially available green roof trays as replicated plots with varying levels of plant species richness (0, 1, 3, or 6 common green roof species per plot, using plants with different functional characteristics). We estimated accumulated plant biomass near the peak of the first full growing season (July 2013) and measured runoff volume after nearly every rain event from September 2012 to September 2013 (33 events) and runoff fluxes of inorganic nutrients ammonium, nitrate, and phosphate from a subset of 10 events. We found that (1) total plant biomass increased with increasing species richness, (2) green roof plots were effective at reducing storm runoff, with vegetation increasing water retention more than soil-like substrate alone, but there was no significant effect of plant species identity or richness on runoff volume, (3) green roof substrate was a significant source of phosphate, regardless of presence/absence of plants, and (4) dissolved inorganic nitrogen (DIN = nitrate + ammonium) runoff fluxes were different among plant species and decreased significantly with increasing plant species richness. The variation in N retention was positively related to variation in plant biomass. Notably, the increased biomass and N retention with species richness in this engineered ecosystem are similar to patterns observed in published studies from grasslands and other well-studied ecosystems. We suggest that more diverse plantings on vegetated roofs may enhance the retention capacity for reactive nitrogen. This is of importance for the sustained health of vegetated roof ecosystems, which over time often experience nitrogen limitation, and is also relevant for water quality in receiving waters

  6. Building Integrated Photovoltaic (BIPV) Roofs for Sustainability and Energy Efficiency

    Science.gov (United States)

    2014-04-01

    heated with a small 580,000 British Thermal Units (BTU) Parker water tube boiler . Two air handlers provide conditioned air to the space. The interior...such as PV adhesive failures . The PV system performed as expected, but is highly susceptible to soiling in low-slope roof applications. The BIPV system...roof, but was insufficient for unanticipated issues with the PV system, such as PV adhesive failures . The PV system performed as expected, but is

  7. Airtightness Results of Roof-Only Air Sealing Strategies on 1 ½-Story Homes in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ojczyk, C.; Murry, T.; Mosiman, G.

    2014-07-01

    In this second study on solutions to ice dams in 1-1/2 story homes, the NorthernSTAR Building America Partnership team analyzed five test homes located in both cold and very cold climates for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. These homes were chosen for testing as they are common in Minnesota and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled the team to compare air tightness data from over 220 homes using similar air seal methods.

  8. Airtightness Results of Roof-Only Air Sealing Strategies on 1-1/2 Story Homes in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ojczyk, C.; Murry, T.; Mosiman, G.

    2014-07-01

    In this second study on solutions to ice dams in 1-1/2 story homes, five test homes located in both cold and very cold climates were analyzed for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. The reason for choosing this house type was they are very common in our area and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR Building America industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled us to compare air tightness data from over 220 homes using similar air seal methods.

  9. Graphene Coatings

    DEFF Research Database (Denmark)

    Stoot, Adam Carsten; Camilli, Luca; Bøggild, Peter

    2014-01-01

    Owing to its remarkable electrical and mechanical properties, graphene has been attracting tremendous interest in materials science. In particular, its chemical stability and impermeability make it a promising protective membrane. However, recent investigations reveal that single layer graphene...... cannot be used as a barrier in the long run, due to galvanic corrosion phenomena arising when oxygen or water penetrate through graphene cracks or domain boundaries. Here, we overcome this issue by using a multilayered (ML) graphene coating. Our lab- as well as industrial-scale tests demonstrate that ML...... graphene can effectively protect Ni in harsh environments, even after long term exposure. This is made possible by the presence of a high number of graphene layers, which can efficiently mask the cracks and domain boundaries defects found in individual layers of graphene. Our findings thus show...

  10. Green roofs and implementing the goals of Smart Growth

    International Nuclear Information System (INIS)

    Loder, A.; Peck, S.W.

    2004-01-01

    Smart Growth is a movement developed by city planners to counteract urban sprawl and inner-city deterioration. This paper explored the use of green roofs as a tangible means to attain the following 4 main goals of Smart Growth: (1) support infill development which refers to the concentration of development in already existing nodes and corridors served by public transit, (2) make cities more liveable, healthy, and environmentally sustainable, (3) create new green space and habitat for biodiversity preservation, and (4) support efficient and green infrastructure. It was suggested that few technologies provide such a wide range of opportunity as green roofs do to generate tangible social, economic and environmental benefits. Roof space represents 15 to 35 per cent of the total land area in a city. In addition to providing stormwater management, green roofs contribute to a reduction of the urban heat island, bringing nature back into the city. It was noted that generating new accessible and inaccessible green space is consistent with the needs and desires or urban dwellers. The extent to which green roofs can provide public benefits depends on the type of design. Green roofs not only cool the buildings they sit upon, but generate cooling for the surrounding area that can result in reduced energy consumption and improvements in air quality. 64 refs., 2 figs

  11. Modelling of green roofs' hydrologic performance using EPA's SWMM.

    Science.gov (United States)

    Burszta-Adamiak, E; Mrowiec, M

    2013-01-01

    Green roofs significantly affect the increase in water retention and thus the management of rain water in urban areas. In Poland, as in many other European countries, excess rainwater resulting from snowmelt and heavy rainfall contributes to the development of local flooding in urban areas. Opportunities to reduce surface runoff and reduce flood risks are among the reasons why green roofs are more likely to be used also in this country. However, there are relatively few data on their in situ performance. In this study the storm water performance was simulated for the green roofs experimental plots using the Storm Water Management Model (SWMM) with Low Impact Development (LID) Controls module (version 5.0.022). The model consists of many parameters for a particular layer of green roofs but simulation results were unsatisfactory considering the hydrologic response of the green roofs. For the majority of the tested rain events, the Nash coefficient had negative values. It indicates a weak fit between observed and measured flow-rates. Therefore complexity of the LID module does not affect the increase of its accuracy. Further research at a technical scale is needed to determine the role of the green roof slope, vegetation cover and drying process during the inter-event periods.

  12. Hydrological Performance of LECA-Based Roofs in Cold Climates

    Directory of Open Access Journals (Sweden)

    Vladimír Hamouz

    2018-03-01

    Full Text Available Rooftops represent a considerable part of the impervious fractions of urban environments. Detaining and retaining runoff from vegetated rooftops can be a significant contribution to reducing the effects of urbanization, with respect to increased runoff peaks and volumes from precipitation events. However, in climates with limited evapotranspiration, a non-vegetated system is a convenient option for stormwater management. A LECA (lightweight expanded clay aggregate-based roof system was established in the coastal area of Trondheim, Norway in 2016. The roof structure consists of a 200 mm-thick layer of LECA® lightweight aggregate, covered by a concrete pavement. The retention in the LECA-based roof was estimated at 9%, which would be equivalent to 0.27 mm/day for the entire period. The LECA-based configuration provided a detention performance for a peak runoff reduction of 95% (median and for a peak delay of 1 h and 15 min (median, respectively. The relatively high moisture levels in the LECA-based roof did not affect the detention performance. Rooftop retrofitting as a form of source control may contribute to a change in runoff characteristics from conventional roofs. This study of the LECA-based roof configuration presents data and performance indicators for stormwater urban planners with regard to water detention capability.

  13. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    Energy Technology Data Exchange (ETDEWEB)

    Syd S. Peng

    2003-01-15

    In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The main accomplishments in this quarter included: (1) laboratory tests have been conducted, (2) with the added trendline analysis method, the accuracy of the data interpretation methodology will be improved and the interfaces and voids can be more reliably detected, (3) method to use torque to thrust ratio as indicator of rock relative hardness has also been explored, and (4) about 80% of the development work for the roof geology mapping program, MRGIS, has completed.

  14. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN MINE ROOF BOLTER DRILLING

    Energy Technology Data Exchange (ETDEWEB)

    Syd S. Peng

    2003-10-15

    In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The main accomplishments in this quarter included: (1) laboratory tests have been conducted, (2) with the added trendline analysis method, the accuracy of the data interpretation methodology will be improved, (3) method to use torque to thrust ratio as indicator of rock relative hardness has also been explored, and (3) about one half of the development work for the roof geology mapping program, MRGIS, has completed.

  15. Impact of height and shape of building roof on air quality in urban street canyons

    Science.gov (United States)

    Yassin, Mohamed F.

    2011-09-01

    A building's roof shape and roof height play an important role in determining pollutant concentrations from vehicle emissions and its complex flow patterns within urban street canyons. The impact of the roof shape and height on wind flow and dispersion of gaseous pollutants from vehicle exhaust within urban canyons were investigated numerically using a Computational Fluid Dynamics (CFD) model. Two-dimensional flow and dispersion of gaseous pollutants were analyzed using standard κ- ɛ turbulence model, which was numerically solved based on Reynolds Averaged Navier-Stokes (RANS) equations. The diffusion fields in the urban canyons were examined with three roof heights ( Z H/ H = 0.17, 0.33 and 0.5) and five roof shapes: (1) flat-shaped roof, (2) slanted-shaped roof, (3) downwind wedge-shaped roof, (4) upwind wedge-shaped roof, and (5) trapezoid-shaped roof. The numerical model was validated against the wind tunnels results in order to optimize the turbulence model. The numerical simulations agreed reasonably with the wind tunnel results. The results obtained indicated that the pollutant concentration increased as the roof height decreases. It also decreased with the slanted and trapezoid-shaped roofs but increased with the flat-shaped roof. The pollutant concentration distributions simulated in the present work, indicated that the variability of the roof shapes and roof heights of the buildings are important factors for estimating air quality within urban canyons.

  16. Composition and Diversity of Avian Communities Using a New Urban Habitat: Green Roofs.

    Science.gov (United States)

    Washburn, Brian E; Swearingin, Ryan M; Pullins, Craig K; Rice, Matthew E

    2016-06-01

    Green roofs on buildings are becoming popular and represent a new component of the urban landscape. Public benefits of green roof projects include reduced stormwater runoff, improved air quality, reduced urban heat island effects, and aesthetic values. As part of a city-wide plan, several green roofs have been constructed at Chicago's O'Hare International Airport (ORD). Like some other landscaping features, green roofs on or near an airport might attract wildlife and thus increase the risk of bird-aircraft collisions. During 2007-2011, we conducted a series of studies to evaluate wildlife use of newly constructed green roofs and traditional (gravel) roofs on buildings at ORD. These green roofs were 0.04-1.62 ha in area and consisted of primarily stonecrop species for vegetation. A total of 188 birds were observed using roofs during this research. Of the birds using green roofs, 66, 23, and 4 % were Killdeer, European Starlings, and Mourning Doves, respectively. Killdeer nested on green roofs, whereas the other species perched, foraged, or loafed. Birds used green roofs almost exclusively between May and October. Overall, avian use of the green roofs was minimal and similar to that of buildings with traditional roofs. Although green roofs with other vegetation types might offer forage or cover to birds and thus attract potentially hazardous wildlife, the stonecrop-vegetated green roofs in this study did not increase the risk of bird-aircraft collisions.

  17. Composition and Diversity of Avian Communities Using a New Urban Habitat: Green Roofs

    Science.gov (United States)

    Washburn, Brian E.; Swearingin, Ryan M.; Pullins, Craig K.; Rice, Matthew E.

    2016-06-01

    Green roofs on buildings are becoming popular and represent a new component of the urban landscape. Public benefits of green roof projects include reduced stormwater runoff, improved air quality, reduced urban heat island effects, and aesthetic values. As part of a city-wide plan, several green roofs have been constructed at Chicago's O'Hare International Airport (ORD). Like some other landscaping features, green roofs on or near an airport might attract wildlife and thus increase the risk of bird-aircraft collisions. During 2007-2011, we conducted a series of studies to evaluate wildlife use of newly constructed green roofs and traditional (gravel) roofs on buildings at ORD. These green roofs were 0.04-1.62 ha in area and consisted of primarily stonecrop species for vegetation. A total of 188 birds were observed using roofs during this research. Of the birds using green roofs, 66, 23, and 4 % were Killdeer, European Starlings, and Mourning Doves, respectively. Killdeer nested on green roofs, whereas the other species perched, foraged, or loafed. Birds used green roofs almost exclusively between May and October. Overall, avian use of the green roofs was minimal and similar to that of buildings with traditional roofs. Although green roofs with other vegetation types might offer forage or cover to birds and thus attract potentially hazardous wildlife, the stonecrop-vegetated green roofs in this study did not increase the risk of bird-aircraft collisions.

  18. Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

    Energy Technology Data Exchange (ETDEWEB)

    Fallahi, A. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States); Duraschlag, H. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States); Elliott, D. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States); Hartsough, J. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States); Shukla, N. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States); Kosny, J. [Fraunhofer Center for Sustainable Energy Systems, Boston, MA (United States)

    2013-12-01

    This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulk insulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosed reflective air space and the second uses spray-applied interior radiation control coatings (IRCC).

  19. Internal Roof and Attic Thermal Radiation Control Retrofit Strategies for Cooling-Dominated Climates

    Energy Technology Data Exchange (ETDEWEB)

    Fallahi, A. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States); Durschlag, H. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States); Elliott, D. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States); Hartsough, J. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States); Shukla, N. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States); Kosny, J. [Fraunhofer Center for Sustainable Energy Systems (CSE), Boston, MA (United States)

    2013-12-01

    This project evaluates the cooling energy savings and cost effectiveness of radiation control retrofit strategies for residential attics in U.S. cooling-dominated climates. Usually, in residential applications, radiation control retrofit strategies are applied below the roof deck or on top of the attic floor insulation. They offer an alternative option to the addition of conventional bulkinsulation such as fiberglass or cellulose insulation. Radiation control is a potentially low-cost energy efficiency retrofit strategy that does not require significant changes to existing homes. In this project, two groups of low-cost radiation control strategies were evaluated for southern U.S. applications. One uses a radiant barrier composed of two aluminum foils combined with an enclosedreflective air space and the second uses spray-applied interior radiation control coatings (IRCC).

  20. FinalReport for completed IPP-0110 and 0110A Projects:"High Energy Ion Technology of Interfacial Thin Film Coatings for Electronic, Optical and Industrial Applications"

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Ian

    2009-09-01

    The DOE-supported IPP (Initiatives for Proliferation Prevention) Project, IPP-0110, and its accompanying 'add-on project' IPP-0110A, entitled 'High Energy Ion Technology of Interfacial Thin Film Coatings for Electronic, Optical and Industrial Applications' was a collaborative project involving the Lawrence Berkeley National Laboratory (LBNL) as the U.S. DOE lab; the US surface modification company, Phygen, Inc., as the US private company involved; and the High Current Electronics Institute (HCEI) of the Russian Academy of Sciences, Tomsk, Siberia, Russia, as the NIS Institute involved. Regular scientific research progress meetings were held to which personnel came from all participating partners. The meetings were held mostly at the Phygen facilities in Minneapolis, Minnesota (with Phygen as host) with meetings also held at Tomsk, Russia (HCEI as host), and at Berkeley, California (LBNL as host) In this way, good exposure of all researchers to the various different laboratories involved was attained. This report contains the Final Reports (final deliverables) from the Russian Institute, HCEI. The first part is that for IPP-0110A (the 'main part' of the overall project) and the second part is that for the add-on project IPP-0110A. These reports are detailed, and contain all aspects of all the research carried out. The project was successful in that all deliverables as specified in the proposals were successfully developed, tested, and delivered to Phygen. All of the plasma hardware was designed, made and tested at HCEI, and the performance was excellent. Some of the machine and performance parameters were certainly of 'world class'. The goals and requirements of the IPP Project were well satisfied. I would like to express my gratitude to the DOE IPP program for support of this project throughout its entire duration, and for the unparalleled opportunity thereby provided for all of the diverse participants in the project to join

  1. Inclusion of cool roofs in nonresidential Title 24 prescriptive requirements

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, Ronnen; Akbari, Hashem; Konopacki, Steve; Bretz, Sarah

    2002-12-15

    Roofs that have high solar reflectance (high ability to reflect sunlight) and high thermal emittance (high ability to radiate heat) tend to stay cool in the sun. The same is true of low-emittance roofs with exceptionally high solar reflectance. Substituting a cool roof for a noncool roof tends to decrease cooling electricity use, cooling power demand, and cooling-equipment capacity requirements, while slightly increasing heating energy consumption. Cool roofs can also lower the ambient air temperature in summer, slowing ozone formation and increasing human comfort. DOE-2.1E building energy simulations indicate that use of a cool roofing material on a prototypical California nonresidential building with a low-sloped roof yields average annual cooling energy savings of approximately 300 kWh/1000 ft2 [3.2 kWh/m2], average annual natural gas deficits of 4.9 therm/1000 ft2 [5.6 MJ/m2], average source energy savings of 2.6 MBTU/1000 ft2 [30 MJ/m2], and average peak power demand savings of 0. 19 kW/1000 ft2 [2.1 W/m2]. The 15-year net present value (NPV) of energy savings averages $450/1000 ft2 [$4.90/m2] with time dependent valuation (TDV), and $370/1000 ft2 [$4.00/m2] without TDV. When cost savings from downsizing cooling equipment are included, the average total savings (15-year NPV + equipment savings) rises to $550/1000 ft2 [$5.90/m2] with TDV, and to $470/1000 ft2 [$5.00/m2] without TDV. Total savings range from 0.18 to 0.77 $/ft2 [1.90 to 8.30 $/m2] with TDV, and from 0.16 to 0.66 $/ft2 [1.70 to 7.10 $/m2] without TDV, across California's 16 climate zones. The typical cost premium for a cool roof is 0.00 to 0.20 $/ft2 [0.00 to 2.20 $/m2]. Cool roofs with premiums up to $0.20/ft2 [$2.20/m2] are expected to be cost effective in climate zones 2 through 16; those with premiums not exceeding $0.18/ft2 [$1.90/m2] are expected to be also cost effective in climate zone 1. Hence, this study recommends that the year-2005 California building energy efficiency code (Title

  2. Inclusion of cool roofs in nonresidential Title 24 prescriptive requirements

    International Nuclear Information System (INIS)

    Levinson, Ronnen; Akbari, Hashem; Konopacki, Steve; Bretz, Sarah

    2005-01-01

    Roofs that have high solar reflectance (high ability to reflect sunlight) and high thermal emittance (high ability to radiate heat) tend to stay cool in the sun. The same is true of low-emittance roofs with exceptionally high solar reflectance. Substituting a cool roof for a non-cool roof tends to decrease cooling electricity use, cooling power demand, and cooling-equipment capacity requirements, while slightly increasing heating energy consumption. Cool roofs can also lower citywide ambient air temperature in summer, slowing ozone formation and increasing human comfort. DOE-2.1E building energy simulations indicate that use of a cool roofing material on a prototypical California nonresidential (NR) building with a low-sloped roof yields average annual cooling energy savings of approximately 3.2 kW h/m 2 (300 kW h/1000 ft 2 ), average annual natural gas deficits of 5.6 MJ/m 2 (4.9 therm/1000 ft 2 ), average annual source energy savings of 30 MJ/m 2 (2.6 MBTU/1000 ft 2 ), and average peak power demand savings of 2.1 W/m 2 (0.19 kW/1000 ft 2 ). The 15-year net present value (NPV) of energy savings averages $4.90/m 2 ($450/1000 ft 2 ) with time-dependent valuation (TDV), and $4.00/m 2 ($370/1000 ft 2 ) without TDV. When cost savings from downsizing cooling equipment are included, the average total savings (15-year NPV+equipment savings) rises to $5.90/m 2 ($550/1000 ft 2 ) with TDV, and to $5.00/m 2 ($470/1000 ft 2 ) without TDV. Total savings range from 1.90 to 8.30 $/m 2 (0.18-0.77 $/ft 2 ) with TDV, and from 1.70 to 7.10 $/m 2 (0.16-0.66 $/ft 2 ) without TDV, across California's 16 climate zones. The typical cost premium for a cool roof is 0.00-2.20 $/m 2 (0.00-0.20 $/ft 2 ). Cool roofs with premiums up to $2.20/m 2 ($0.20/ft 2 ) are expected to be cost effective in climate zones 2-16; those with premiums not exceeding $1.90/m 2 ($0.18/ft 2 ) are expected to be also cost effective in climate zone 1. Hence, this study recommends that the year-2005 California

  3. Experimental study on foam coverage on simulated longwall roof

    Science.gov (United States)

    Reed, W.R.; Zheng, Y.; Klima, S.; Shahan, M.R.; Beck, T.W.

    2018-01-01

    Testing was conducted to determine the ability of foam to maintain roof coverage in a simulated longwall mining environment. Approximately 27 percent of respirable coal mine dust can be attributed to longwall shield movement, and developing controls for this dust source has been difficult. The application of foam is a possible dust control method for this source. Laboratory testing of two foam agents was conducted to determine the ability of the foam to adhere to a simulated longwall face roof surface. Two different foam generation methods were used: compressed air and blower air. Using a new imaging technology, image processing and analysis utilizing ImageJ software produced quantifiable results of foam roof coverage. For compressed air foam in 3.3 m/s (650 fpm) ventilation, 98 percent of agent A was intact while 95 percent of agent B was intact on the roof at three minutes after application. At 30 minutes after application, 94 percent of agent A was intact while only 20 percent of agent B remained. For blower air in 3.3 m/s (650 fpm) ventilation, the results were dependent upon nozzle type. Three different nozzles were tested. At 30 min after application, 74 to 92 percent of foam agent A remained, while 3 to 50 percent of foam agent B remained. Compressed air foam seems to remain intact for longer durations and is easier to apply than blower air foam. However, more water drained from the foam when using compressed air foam, which demonstrates that blower air foam retains more water at the roof surface. Agent A seemed to be the better performer as far as roof application is concerned. This testing demonstrates that roof application of foam is feasible and is able to withstand a typical face ventilation velocity, establishing this technique’s potential for longwall shield dust control. PMID:29563765

  4. Manipulating soil microbial communities in extensive green roof substrates.

    Science.gov (United States)

    Molineux, Chloe J; Connop, Stuart P; Gange, Alan C

    2014-09-15

    There has been very little investigation into the soil microbial community on green roofs, yet this below ground habitat is vital for ecosystem functioning. Green roofs are often harsh environments that would greatly benefit from having a healthy microbial system, allowing efficient nutrient cycling and a degree of drought tolerance in dry summer months. To test if green roof microbial communities could be manipulated, we added mycorrhizal fungi and a microbial mixture ('compost tea') to green roof rootzones, composed mainly of crushed brick or crushed concrete. The study revealed that growing media type and depth play a vital role in the microbial ecology of green roofs. There are complex relationships between depth and type of substrate and the biomass of different microbial groups, with no clear pattern being observed. Following the addition of inoculants, bacterial groups tended to increase in biomass in shallower substrates, whereas fungal biomass change was dependent on depth and type of substrate. Increased fungal biomass was found in shallow plots containing more crushed concrete and deeper plots containing more crushed brick where compost tea (a live mixture of beneficial bacteria) was added, perhaps due to the presence of helper bacteria for arbuscular mycorrhizal fungi (AMF). Often there was not an additive affect of the microbial inoculations but instead an antagonistic interaction between the added AM fungi and the compost tea. This suggests that some species of microbes may not be compatible with others, as competition for limited resources occurs within the various substrates. The overall results suggest that microbial inoculations of green roof habitats are sustainable. They need only be done once for increased biomass to be found in subsequent years, indicating that this is a novel and viable method of enhancing roof community composition. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Developing resilient green roofs in a dry climate.

    Science.gov (United States)

    Razzaghmanesh, M; Beecham, S; Brien, C J

    2014-08-15

    Living roofs are an emerging green infrastructure technology that can potentially be used to ameliorate both climate change and urban heat island effects. There is not much information regarding the design of green roofs for dry climates and so the aim of this study was to develop low maintenance and unfertilized green roofs for a dry climate. This paper describes the effects of four important elements of green roofs namely slope, depth, growing media and plant species and their possible interactions in terms of plant growth responses in a dry climate. Sixteen medium-scale green roofs were set up and monitored during a one year period. This experiment consisted of twelve vegetated platforms and four non-vegetated platforms as controls. The design for the experiment was a split-split-plot design in which the factors Slope (1° and 25°) and Depth (100mm, 300 mm) were randomized to the platforms (main plots). Root depth and volume, average height of plants, final dry biomass and ground cover, relative growth rate, final dry shoot-root ratio, water use efficiency and leaf succulence were studied during a twelve month period. The results showed little growth of the plants in media type A, whilst the growth was significant in both media types B and C. On average, a 90% survival rate of plants was observed. Also the growth indices indicated that some plants can grow efficiently in the harsh environment created by green roofs in a dry climate. The root growth pattern showed that retained water in the drainage layer is an alternative source of water for plants. It was also shown that stormwater can be used as a source of irrigation water for green roofs during six months of the year at the study site. In summary, mild sloping intensive systems containing media type C and planted with either Chrysocephalum apiculatum or Disphyma crassifolium showed the best performance. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Analysis of the Umbrella Roof for lifting

    International Nuclear Information System (INIS)

    Shaaban, A.

    1983-01-01

    In addition to supporting the dead loads and the operational loads, the Umbrella Roof (UR) has two major functions to which it was designed. First is to allow access for repair and removal of any of the TF coils, the upper PF coils and the Vacuum Vessel sections; and second, is to reproduce the exact positioning of the upper PF coils every time the UR is placed over the Tokamac. To provide these functions, the UR is designed to be lifted as one integrated structure to which the upper PF coils are attached. In order to ensure precise positioning of the UR, a redundant system of 13 guide pins were provided on the bottom of the radial beams, and four shear lugs were provided atop the central column. Mating reciprocals with very close tolerance for the guide pins were provided in the tops of the 13 peripheral columns. To meet close tolerances and to accommodate such high redundancy in match points, accurate analysis was necessary by which the center of gravity of the UR can be located and the deflection of all match points can be computed. Also stress analysis of the members of the UR was necessary because when the UR is lifted it is denied the midpoint support over the center column; and also the beams of the UR are not interconnected by moment-capable joints, thus if provisions are not made to support every radial beam, those which are not supported would yield and collapse. In this paper, the lifting schemes proposed for the UR are discussed and the results of the analysis performed for the elected scheme are presented. Also presented is a unique application of the NASTRAN code by which the center of gravity of the UR was located by allowing a refined model of the UR to swing until it came to rest under an arbitrary lift point

  7. Evaluating Cool Impervious Surfaces: Application to an Energy-Efficient Residential Roof and to City Pavements

    Science.gov (United States)

    Rosado, Pablo Javier

    Summer urban heat island (UHI) refers to the phenomenon of having higher urban temperatures compared to the those in surrounding suburban and rural areas. Higher urban air temperatures lead to increased cooling demand, accelerates the formation of smog, and contributes to the generation of greenhouse gas emissions. Dark-colored impervious surfaces cover a significant fraction of an urban fabric, and as hot and dry surfaces, are a major contributor to the UHI effect. Adopting solar-reflective ("cool") roofs and cool pavements, and increasing the urban vegetation, are strategies proven to mitigate urban heat islands. These strategies often have an "indirect" effect (ambient cooling) and "direct" effect (change in solar energy flux entering the conditioned space) on the energy use of buildings. This work investigates some elements of the UHI mitigation strategies, specifically the annual direct effect of a cool roof, and the direct and indirect effects of cool pavements. The first topic researched in this paper consists in an experimental assessment of the direct effects from replacing a conventional dark roof with a highly energy-efficient cool roof. The study measures and calculates the annual benefits of the cool roof on the cooling and heating energy uses, and the associated emission reductions. The energy savings attributed to the cool roof are validated by measuring the difference between the homes in the heat loads that entered the conditioned space through the ceiling and HVAC ducts. Fractional annual cooling energy savings (26%) were 2.6 times the 10% daily cooling energy savings measured in a previous study that used a white coating to increase the albedo of an asphalt shingle roof by the same amount (0.44). The improved cooling energy savings (26% vs. 10%) may be attributed to the cool tile's above-sheathing ventilation, rather than to its high thermal mass. The roof also provided energy savings during the heating season, yielding fractional annual gas

  8. Anti-Corrosion Coating

    Science.gov (United States)

    1986-01-01

    SuperSpan RM 8000 is an anti-corrosion coating which effectively counteracts acid degradation, abrasive wear, and cracking in power industry facilities. It was developed by RM Industrial Products Company, Inc. with NERAC assistance. It had previously been necessary to shut down plants to repair or replace corroded duct-work in coal burning utilities. NASA-developed technology was especially useful in areas relating to thermoconductivity of carbon steel and the bonding characteristics of polymers. The product has sold well.

  9. Portland's experience with land use tools to promote green roofs

    International Nuclear Information System (INIS)

    Johnson, M.

    2004-01-01

    In the late 1990s, the City of Portland, Oregon faced environmental challenges that prompted the City to mandate environmentally sensitive development. Several programs were developed in response to these challenges, some of which resulted in the creation of land use policies and incentives that promote green roofs. Zoning code provisions were adopted in 2001 to promote eco-roofs in an effort to reduce stormwater runoff, mitigate urban heat island effects, provide habitat for birds, and improve air quality and energy efficiency. The Central City Fundamental Design Guidelines were also revised to encourage eco-roof development. In 2002, the South Waterfront Plan was created to integrate ecological design into an urban environment through sustainability principles and practices. Land use tools were developed to introduce developers to an approach that reduced energy costs and stormwater costs, while also contributing to a project's marketability. These tools were created with the support of programs and policies such as the CSO (Combined Sewer Overflow) Program; eco-roof research which began in 1995 to determine the stormwater management potential of eco-Green roofs; technical assistance to encourage and highlight sustainable development practices; the Stormwater Management Manual that set standards for the amount and quality of stormwater runoff leaving development sites; the G/Rated Program that offers resources for green building practices; the Green Investment Fund that supports the G/Rated Program; and, the Portland Development Commission Green Building Policy financing tool for earth-friendly designs and materials. 34 refs., 2 figs

  10. Retention performance of green roofs in three different climate regions

    Science.gov (United States)

    Sims, Andrew W.; Robinson, Clare E.; Smart, Charles C.; Voogt, James A.; Hay, Geoffrey J.; Lundholm, Jeremey T.; Powers, Brandon; O'Carroll, Denis M.

    2016-11-01

    Green roofs are becoming increasingly popular for moderating stormwater runoff in urban areas. This study investigated the impact different climates have on the retention performance of identical green roofs installed in London Ontario (humid continental), Calgary Alberta (semi-arid, continental), and Halifax Nova Scotia (humid, maritime). Drier climates were found to have greater percent cumulative stormwater retention with Calgary (67%) having significantly better percent retention than both London (48%) and Halifax (34%). However, over the same study period the green roof in London retained the greatest depth of stormwater (598 mm), followed by the green roof in Halifax (471 mm) and then Calgary (411 mm). The impact of climate was largest for medium sized storms where the antecedent moisture condition (AMC) at the beginning of a rainfall event governs retention performance. Importantly AMC was a very good predictor of stormwater retention, with similar retention at all three sites for a given AMC, emphasizing that AMC is a relevant indicator of retention performance in any climate. For large rainfall events (i.e., >45 mm) green roof average retention ranged between 16% and 29% in all cities. Overall, drier climates have superior retention due to lower AMC in the media. However, moderate and wet climates still provide substantial total volume reduction benefits.

  11. A pilot study to evaluate runoff quantity from green roofs.

    Science.gov (United States)

    Lee, Ju Young; Lee, Min Jung; Han, Mooyoung

    2015-04-01

    The use of green roofs is gaining increased recognition in many countries as a solution that can be used to improve environmental quality and reduce runoff quantity. To achieve these goals, pilot-scale green roof assemblies have been constructed and operated in an urban setting. From a stormwater management perspective, green roofs are 42.8-60.8% effective in reducing runoff for 200 mm soil depth and 13.8-34.4% effective in reducing runoff for 150 mm soil depth. By using Spearman rank correlation analysis, high rainfall intensity was shown to have a negative relationship with delayed occurrence time, demonstrating that the soil media in green roofs do not efficiently retain rainwater. Increasing the number of antecedent dry days can help to improve water retention capacity and delay occurrence time. From the viewpoint of runoff water quality, green roofs are regarded as the best management practice by filtration and adsorption through growth media (soil). Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. The green roof dilemma - discussion of Francis and Lorimer (2011).

    Science.gov (United States)

    Henry, Alexandre; Frascaria-Lacoste, Nathalie

    2012-08-15

    Urban ecosystems are the most complex mosaics of vegetative land cover that can be found. In a recent paper, Francis and Lorimer (2011) evaluated the reconciliation potential of living roofs and walls. For these authors, these two techniques for habitat improvement have strong potential for urban reconciliation ecology. However they have some ecological and societal limitations such as the physical extreme environmental characteristics, the monetary investment and the cultural perceptions of urban nature. We are interested in their results and support their conclusions. However, for a considerable time, green roofs have been designed to provide urban greenery for buildings and the green roof market has only focused on extensive roof at a restricted scale within cities. Thus, we have strong doubts about the relevance of their use as possible integrated elements of the network. Furthermore, without dynamic progress in research and the implementation of well-thought-out policies, what will be the real capital gain from green roofs with respect to land-use complementation in cities? If we agree with Francis and Lorimer (2011) considering that urban reconciliation ecology between nature and citizens is a current major challenge, then "adaptive collaborative management" is a fundamental requirement. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Residential roof condition assessment system using deep learning

    Science.gov (United States)

    Wang, Fan; Kerekes, John P.; Xu, Zhuoyi; Wang, Yandong

    2018-01-01

    The emergence of high resolution (HR) and ultra high resolution (UHR) airborne remote sensing imagery is enabling humans to move beyond traditional land cover analysis applications to the detailed characterization of surface objects. A residential roof condition assessment method using techniques from deep learning is presented. The proposed method operates on individual roofs and divides the task into two stages: (1) roof segmentation, followed by (2) condition classification of the segmented roof regions. As the first step in this process, a self-tuning method is proposed to segment the images into small homogeneous areas. The segmentation is initialized with simple linear iterative clustering followed by deep learned feature extraction and region merging, with the optimal result selected by an unsupervised index, Q. After the segmentation, a pretrained residual network is fine-tuned on the augmented roof segments using a proposed k-pixel extension technique for classification. The effectiveness of the proposed algorithm was demonstrated on both HR and UHR imagery collected by EagleView over different study sites. The proposed algorithm has yielded promising results and has outperformed traditional machine learning methods using hand-crafted features.

  14. Multispectral Image Analysis for Astaxanthin Coating Classification

    DEFF Research Database (Denmark)

    Ljungqvist, Martin Georg; Ersbøll, Bjarne Kjær; Nielsen, Michael Engelbrecht

    2012-01-01

    Industrial quality inspection using image analysis on astaxanthin coating in aquaculture feed pellets is of great importance for automatic production control. The pellets were divided into two groups: one with pellets coated using synthetic astaxanthin in fish oil and the other with pellets coated...

  15. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    Energy Technology Data Exchange (ETDEWEB)

    Syd S. Peng

    2004-04-15

    A one-year non-cost extension has been granted for this project. In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The main accomplishments in this quarter included: (1) laboratory tests have been conducted, (2) with the added trendline analysis method, the accuracy of the data interpretation methodology will be improved and the interfaces and voids can be more reliably detected, (3) method to use torque to thrust ratio as indicator of rock relative hardness has also been explored, and (3) about 80% of the development work for the roof geology mapping program, MRGIS, has completed and a special version of the program is in the field testing stage.

  16. EVALUATION OF ROOF BOLTING REQUIREMENTS BASED ON IN-MINE ROOF BOLTER DRILLING

    Energy Technology Data Exchange (ETDEWEB)

    Syd S. Peng

    2004-09-15

    In this quarter, the field, theoretical and programming works have been performed toward achieving the research goals set in the proposal. The main accomplishments in this quarter included: (1) two more sets of field tests have been conducted in an underground coal mine, (2) optimization studies of the control parameters have been conducted, (3) method to use torque to thrust ratio as indicator of rock relative hardness has also been explored, and (3) about 97% of the development work for the roof geology mapping program, MRGIS, has completed, (4) A special version of the geology mapping program for a limestone mine has been developed. The field test for the software and hardware has been successfully finished.

  17. Procedure for Installing a photovoltaic system on roofs in Cuban Ron Corporation S.A

    International Nuclear Information System (INIS)

    Guzmán Villavicencio, Mayra; Águila Bernal, Inoel; Torres Águila, José M.; Soto Castellón, Carlos R.

    2017-01-01

    In this work, a methodological procedure developed from experiences gained during the project "Photovoltaic installation on the roofs of the Central Rum Factory for operation in self consumption and public MT grid connection” is presented, which was held along with UGAO-AINAIR signature. It is developed taking into account the need to further consolidate the dominance of this alternative energy technology, which is the first experience in such facilities for both, the rum industry and process industries in Cuba. There are no technical rules that regulate requirements to be considered during the conceptual stage of projects for the introduction of photovoltaic systems connected to the grid. The methodological procedure presented provides guidance for its application in other entities, resulting necessary its elaboration to ensure technical stability and reliability of systems during its life. (author)

  18. Theoretical evaluation of thermal and energy performance of tropical green roofs

    International Nuclear Information System (INIS)

    Tsang, S.W.; Jim, C.Y.

    2011-01-01

    The thermal and energy efficiency of tropical green roofs is assessed by a theoretical model to clarify the contribution of underlying factors. The suitability of 1400 high-rise public housing blocks in Hong Kong for rooftop greening was assessed by remote sensing images. Weather and microclimatic-soil monitoring data of an experimental green roof provided the basis for computations. Roof greening prevented a huge amount of solar energy at 43.9 TJ in one summer from penetrating the buildings to bring significant energy saving. Thermal performance of humid-tropical green roofs, with greater latent heat dissipation, is twice more effective than the temperate ones. The energy balance model shows that solar energy absorption by bare and green roofs depends on shortwave rather than longwave radiation. Heat flux into a building indicates a one-day time lag after a sunshine day. With restricted evapotranspiration, bare roofs have more sensible heat and heat storage than green roofs. The bare roof albedo of 0.15, comparing with 0.30 of green roof, renders 75% higher heat storage. Small increase in convection coefficient from 12 to 16 could amplify 24% and 45% of latent heat dissipation respectively for bare and green roofs. Doubling the soil water availability could halve the heat storage of green roofs. -- Highlights: → We developed a theoretical model to calculate the thermal performance of tropical green roofs. → Bare roofs have more sensible heat and heat storage than green roofs. → Latent heat dissipation of tropical green roofs is twice that of temperate counterparts. → Heat flux through the roof into a building demonstrates a one-day time lag after a long sunshine day. → Green roofs can block 43.9 TJ of solar energy penetration into public housing buildings in one summer.

  19. Mathematical modeling of large floating roof reservoir temperature arena

    Directory of Open Access Journals (Sweden)

    Liu Yang

    2018-03-01

    Full Text Available The current study is a simplification of related components of large floating roof tank and modeling for three dimensional temperature field of large floating roof tank. The heat transfer involves its transfer between the hot fluid in the oil tank, between the hot fluid and the tank wall and between the tank wall and the external environment. The mathematical model of heat transfer and flow of oil in the tank simulates the temperature field of oil in tank. Oil temperature field of large floating roof tank is obtained by numerical simulation, map the curve of central temperature dynamics with time and analyze axial and radial temperature of storage tank. It determines the distribution of low temperature storage tank location based on the thickness of the reservoir temperature. Finally, it compared the calculated results and the field test data; eventually validated the calculated results based on the experimental results.

  20. Plant functional traits predict green roof ecosystem services.

    Science.gov (United States)

    Lundholm, Jeremy; Tran, Stephanie; Gebert, Luke

    2015-02-17

    Plants make important contributions to the services provided by engineered ecosystems such as green roofs. Ecologists use plant species traits as generic predictors of geographical distribution, interactions with other species, and ecosystem functioning, but this approach has been little used to optimize engineered ecosystems. Four plant species traits (height, individual leaf area, specific leaf area, and leaf dry matter content) were evaluated as predictors of ecosystem properties and services in a modular green roof system planted with 21 species. Six indicators of ecosystem services, incorporating thermal, hydrological, water quality, and carbon sequestration functions, were predicted by the four plant traits directly or indirectly via their effects on aggregate ecosystem properties, including canopy density and albedo. Species average height and specific leaf area were the most useful traits, predicting several services via effects on canopy density or growth rate. This study demonstrates that easily measured plant traits can be used to select species to optimize green roof performance across multiple key services.

  1. Solare Cell Roof Tile And Method Of Forming Same

    Science.gov (United States)

    Hanoka, Jack I.; Real, Markus

    1999-11-16

    A solar cell roof tile includes a front support layer, a transparent encapsulant layer, a plurality of interconnected solar cells and a backskin layer. The front support layer is formed of light transmitting material and has first and second surfaces. The transparent encapsulant layer is disposed adjacent the second surface of the front support layer. The interconnected solar cells has a first surface disposed adjacent the transparent encapsulant layer. The backskin layer has a first surface disposed adjacent a second surface of the interconnected solar cells, wherein a portion of the backskin layer wraps around and contacts the first surface of the front support layer to form the border region. A portion of the border region has an extended width. The solar cell roof tile may have stand-offs disposed on the extended width border region for providing vertical spacing with respect to an adjacent solar cell roof tile.

  2. Case study: design, operation, maintenance and water quality management of sustainable storm water ponds for roof runoff.

    Science.gov (United States)

    Scholz, Miklas

    2004-12-01

    The purpose of this case study was to optimise design, operation and maintenance guidelines, and to assess the water treatment potential of a storm water pond system after 15 months of operation. The system was based on a combined silt trap, attenuation pond and vegetated infiltration basin. This combination was used as the basis for construction of a roof water runoff system from a single domestic property. United Kingdom Building Research Establishment and Construction Industry Research and Information Association, and German Association for Water, Wastewater and Waste design guidelines were tested. These design guidelines failed because they did not consider local conditions. The infiltration function for the infiltration basin was logarithmic. Algal control techniques were successfully applied, and treatment of rainwater runoff from roofs was found to be largely unnecessary for recycling (e.g., watering plants). However, seasonal and diurnal variations of biochemical oxygen demand, dissolved oxygen and pH were recorded.

  3. Vegetation composition and structure significantly influence green roof performance

    Energy Technology Data Exchange (ETDEWEB)

    Dunnett, N.; Nagase, A.; Booth, R.; Grime, P. [Sheffield Univ., Sheffield (United Kingdom). Dept. of Landscape Architecture

    2005-07-01

    The majority of published literature on green roofs contains little specific information on the contribution of plants to the various functions and properties of green roofs. This paper reviewed previously published material in an attempt to shed light on the role of vegetation composition in green roof systems, with specific reference to hydrology and biodiversity support. Two ongoing experiments at the University of Sheffield were then considered: (1) a comparison of quality and quantity of runoff from different types of vegetation; and (2) a comparison of flowering seasons and biodiversity support of different vegetation. Results of the studies showed that there was no general pattern of variation in runoff that could be related to vegetation complexity or taxonomic composition of the communities. During the winter months, high precipitation quickly saturated the soil and percolate losses were similar for all treatments. In the summer, throughflow losses differed between treatments in relation to the structure of the plant canopy. Differing mechanisms resulted in variations in the volume of percolate that was collected. Lower volumes of percolate were observed in herb-only monocultures of Leontdon hispidus, a species with a high water content. Tap-rooted species were seen to more effectively absorb soil moisture. The biodiversity support study focused on the study of Sedum species and Labiatae species, which suggested that mixed vegetation containing these species had a far greater likelihood of attracting wild bees to support pollination. Results of the studies indicated that green roof vegetation with greater structural and species diversity may provide different benefits than sedum-dominated roots. Further studies are needed to investigate the trade-offs between vegetation types, and green roof functions and performance in order to justify calls for a wider diversity of green roof types. 8 refs., 2 tabs., 1 fig.

  4. TV borehole inspection and vacuum testing of roof strata

    International Nuclear Information System (INIS)

    Herget, G.

    1982-01-01

    To improve quality control of roof conditions, a program was carried out at Elliot Lake uranium mines in Ontario, Canada to test a portable TV camera system. This camera has a 29 mm diameter probe and is capable of identifying crack locations, crack width and approximate dip direction. The extent of fractures in the roof was checked with the aid of a vacuum system by placing packers in various boreholes and checking for communication. The removal of some rock bolts indicated an increase in fracture extent

  5. Crystalline roof glazing - Westside shopping centre, Berne; Kristalline Dachverglasungen

    Energy Technology Data Exchange (ETDEWEB)

    Enkerli, W.

    2009-07-01

    This illustrated article takes a look at the new shopping and leisure centre on the western outskirts of Berne, Switzerland. In particular, the roof of this unusual building over the motorway with its sloping walls and zig-zag design is looked at. The centre's shopping mall, adventure baths and spa, a multiplex cinema, an old peoples' home and a hotel are briefly discussed, as is the embedding of the centre in its suburban environment. The roof construction with its crystalline skylights is examined and discussed in detail. The centre's building technical services are also briefly commented on.

  6. Retention performance of green roofs in representative climates worldwide

    Science.gov (United States)

    Viola, F.; Hellies, M.; Deidda, R.

    2017-10-01

    The ongoing process of global urbanization contributes to an increase in stormwater runoff from impervious surfaces, threatening also water quality. Green roofs have been proved to be innovative stormwater management measures to partially restore natural states, enhancing interception, infiltration and evapotranspiration fluxes. The amount of water that is retained within green roofs depends not only on their depth, but also on the climate, which drives the stochastic soil moisture dynamic. In this context, a simple tool for assessing performance of green roofs worldwide in terms of retained water is still missing and highly desirable for practical assessments. The aim of this work is to explore retention performance of green roofs as a function of their depth and in different climate regimes. Two soil depths are investigated, one representing the intensive configuration and another representing the extensive one. The role of the climate in driving water retention has been represented by rainfall and potential evapotranspiration dynamics. A simple conceptual weather generator has been implemented and used for stochastic simulation of daily rainfall and potential evapotranspiration. Stochastic forcing is used as an input of a simple conceptual hydrological model for estimating long-term water partitioning between rainfall, runoff and actual evapotranspiration. Coupling the stochastic weather generator with the conceptual hydrological model, we assessed the amount of rainfall diverted into evapotranspiration for different combinations of annual rainfall and potential evapotranspiration in five representative climatic regimes. Results quantified the capabilities of green roofs in retaining rainfall and consequently in reducing discharges into sewer systems at an annual time scale. The role of substrate depth has been recognized to be crucial in determining green roofs retention performance, which in general increase from extensive to intensive settings. Looking at the

  7. Modelling of green roof hydrological performance for urban drainage applications

    DEFF Research Database (Denmark)

    Locatelli, Luca; Mark, Ole; Mikkelsen, Peter Steen

    2014-01-01

    from 3 different extensive sedum roofs in Denmark. These data consist of high-resolution measurements of runoff, precipitation and atmospheric variables in the period 2010–2012. The hydrological response of green roofs was quantified based on statistical analysis of the results of a 22-year (1989...... return period. Annual runoff volumes were estimated to be 43–68% of the total precipitation. The peak time delay was found to greatly vary from 0 to more than 40 min depending on the type of event, and a general decrease in the time delay was observed for increasing rainfall intensities. Furthermore...

  8. Component characterization and predictive modeling for green roof substrates optimized to adsorb P and improve runoff quality: A review.

    Science.gov (United States)

    Jennett, Tyson S; Zheng, Youbin

    2018-06-01

    This review is a synthesis of the current knowledge regarding the effects of green roof substrate components and their retentive capacity for nutrients, particularly phosphorus (P). Substrates may behave as either sources or sinks of P depending on the components they are formulated from, and to date, the total P-adsorbing capacity of a substrate has not been quantified as the sum of the contributions of its components. Few direct links have been established among substrate components and their physicochemical characteristics that would affect P-retention. A survey of recent literature presented herein highlights the trends within individual component selection (clays and clay-like material, organics, conventional soil and sands, lightweight inorganics, and industrial wastes and synthetics) for those most common during substrate formulation internationally. Component selection will vary with respect to ease of sourcing component materials, cost of components, nutrient-retention capacity, and environmental sustainability. However, the number of distinct components considered for inclusion in green roof substrates continues to expand, as the desires of growers, material suppliers, researchers and industry stakeholders are incorporated into decision-making. Furthermore, current attempts to characterize the most often used substrate components are also presented whereby runoff quality is correlated to entire substrate performance. With the use of well-described characterization (constant capacitance model) and modeling techniques (the soil assemblage model), it is proposed that substrates optimized for P adsorption may be developed through careful selection of components with prior knowledge of their chemical properties, that may increase retention of P in plant-available forms, thereby reducing green roof fertilizer requirements and P losses in roof runoff. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. The Target Industries: Profiles of Five Hazardous Occupations.

    Science.gov (United States)

    Occupational Safety and Health Administration, Washington, DC.

    To contribute to a fuller understanding and awareness of the hazards involved in industries as well as to call attention to steps being taken to solve safety problems, this pamphlet surveys five industries cited among those having the highest rates of job-related injuries in the country. Industries include: (1) Roofing and Sheet Metal, (2)…

  10. EXTRACTION OF ROOF LINES FROM HIGH-RESOLUTION IMAGES BY A GROUPING METHOD

    Directory of Open Access Journals (Sweden)

    A. P. Dal Poz

    2016-06-01

    Full Text Available This paper proposes a method for extracting groups of straight lines that represent roof boundaries and roof ridgelines from highresolution aerial images using corresponding Airborne Laser Scanner (ALS roof polyhedrons as initial approximations. The proposed method is based on two main steps. First, straight lines that are candidates to represent roof ridgelines and roof boundaries of a building are extracted from the aerial image. Second, a group of straight lines that represent roof boundaries and roof ridgelines of a selected building is obtained through the optimization of a Markov Random Field (MRF-based energy function using the genetic algorithm optimization method. The formulation of this energy function considers several attributes, such as the proximity of the extracted straight lines to the corresponding projected ALS-derived roof polyhedron and the rectangularity (extracted straight lines that intersect at nearly 90°. Experimental results are presented and discussed in this paper.

  11. Study of wind forces on low-rise hip-roof building

    African Journals Online (AJOL)

    DR OKE

    to predict the wind loads and the flow patterns around the hip-roof building. .... various wind angle attack on the roof using CFD simulation. .... SIMPLE algorithm substitutes the flux correction equations into the discrete continuity equation to ...

  12. Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Kohta [Building Science Corporation, Westford, MA (United States); Lstiburek, Joseph W. [Building Science Corporation, Westford, MA (United States)

    2015-09-01

    Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a control vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a diffusion vent detail, capped with vapor permeable roof membrane. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

  13. System for monitoring of green roof performance: use of weighing roof segment and non-invasive visualization

    Science.gov (United States)

    Jelinkova, Vladmira; Dohnal, Michal; Picek, Tomas; Sacha, Jan

    2015-04-01

    Understanding the performance of technogenic substrates for green roofs is a significant task in the framework of sustainable urban planning and water/energy management. The potential retention and detention of the anthropogenic, light weight soil systems and their temporal soil structure changes are of major importance. A green roof test segment was built to investigate the benefits of such anthropogenic systems. Adaptable low-cost system allows long-term monitoring of preferred characteristics. Temperature and water balance measurements complemented with meteorological observations and knowledge of physical properties of the substrates provide basis for detailed analysis of thermal and hydrological regime in green roof systems. The first results confirmed the benefits of green roof systems. The reduction of temperature fluctuations as well as rainfall runoff was significant. Depending on numerous factors such substrate material or vegetation cover the test green roof suppressed the roof temperature amplitude for the period analyzed. The ability to completely prevent (light rainfall events) or reduce and delay (medium and heavy rainfall events) the peak runoff was also analyzed. Special attention is being paid to the assessment of soil structural properties related to possible aggregation/disaggregation, root growth, weather conditions and associated structural changes using non-invasive imaging method. X-ray computed microtomography of undisturbed soil samples (taken from experimental segments) is used for description of pore space geometry, evaluation of surface to volume ratio, additionally for description of cracks and macropores as a product of soil flora and fauna activity. The information from computed tomography imaging will be used for numerical modeling of water flow in variable saturated porous media. The research was realized as a part of the University Centre for Energy Efficient Buildings supported by the EU and with financial support from the Czech

  14. Digging the New York City Skyline: soil fungal communities in green roofs and city parks.

    Directory of Open Access Journals (Sweden)

    Krista L McGuire

    Full Text Available In urban environments, green roofs provide a number of benefits, including decreased urban heat island effects and reduced energy costs for buildings. However, little research has been done on the non-plant biota associated with green roofs, which likely affect their functionality. For the current study, we evaluated whether or not green roofs planted with two native plant communities in New York City functioned as habitats for soil fungal communities, and compared fungal communities in green roof growing media to soil microbial composition in five city parks, including Central Park and the High Line. Ten replicate roofs were sampled one year after planting; three of these roofs were more intensively sampled and compared to nearby city parks. Using Illumina sequencing of the fungal ITS region we found that green roofs supported a diverse fungal community, with numerous taxa belonging to fungal groups capable of surviving in disturbed and polluted habitats. Across roofs, there was significant biogeographical clustering of fungal communities, indicating that community assembly of roof microbes across the greater New York City area is locally variable. Green roof fungal communities were compositionally distinct from city parks and only 54% of the green roof taxa were also found in the park soils. Phospholipid fatty acid analysis revealed that park soils had greater microbial biomass and higher bacterial to fungal ratios than green roof substrates. City park soils were also more enriched with heavy metals, had lower pH, and lower quantities of total bases (Ca, K, and Mg compared to green roof substrates. While fungal communities were compositionally distinct across green roofs, they did not differentiate by plant community. Together, these results suggest that fungi living in the growing medium of green roofs may be an underestimated component of these biotic systems functioning to support some of the valued ecological services of green roofs.

  15. Digging the New York City Skyline: soil fungal communities in green roofs and city parks.

    Science.gov (United States)

    McGuire, Krista L; Payne, Sara G; Palmer, Matthew I; Gillikin, Caitlyn M; Keefe, Dominique; Kim, Su Jin; Gedallovich, Seren M; Discenza, Julia; Rangamannar, Ramya; Koshner, Jennifer A; Massmann, Audrey L; Orazi, Giulia; Essene, Adam; Leff, Jonathan W; Fierer, Noah

    2013-01-01

    In urban environments, green roofs provide a number of benefits, including decreased urban heat island effects and reduced energy costs for buildings. However, little research has been done on the non-plant biota associated with green roofs, which likely affect their functionality. For the current study, we evaluated whether or not green roofs planted with two native plant communities in New York City functioned as habitats for soil fungal communities, and compared fungal communities in green roof growing media to soil microbial composition in five city parks, including Central Park and the High Line. Ten replicate roofs were sampled one year after planting; three of these roofs were more intensively sampled and compared to nearby city parks. Using Illumina sequencing of the fungal ITS region we found that green roofs supported a diverse fungal community, with numerous taxa belonging to fungal groups capable of surviving in disturbed and polluted habitats. Across roofs, there was significant biogeographical clustering of fungal communities, indicating that community assembly of roof microbes across the greater New York City area is locally variable. Green roof fungal communities were compositionally distinct from city parks and only 54% of the green roof taxa were also found in the park soils. Phospholipid fatty acid analysis revealed that park soils had greater microbial biomass and higher bacterial to fungal ratios than green roof substrates. City park soils were also more enriched with heavy metals, had lower pH, and lower quantities of total bases (Ca, K, and Mg) compared to green roof substrates. While fungal communities were compositionally distinct across green roofs, they did not differentiate by plant community. Together, these results suggest that fungi living in the growing medium of green roofs may be an underestimated component of these biotic systems functioning to support some of the valued ecological services of green roofs.

  16. Pemanfaatan Green Roof sebagai Media Filter Air Hujan di Kota Pontianak

    OpenAIRE

    Uria Karlena Sely Sakong

    2013-01-01

    Penelitian ini bertujuan untuk mempelajari pengaruh green roof terhadap kualitas air hujan di KotaPontianak. Pengaruh tersebut dipelajari dengan cara membandingkan antara kualitas air hujan yang melewatigreen roof dengan kualitas air yang tidak melewati green roof. Penelitian diawali dengan merancang danmembuat model green roof. Pengambilan sampel dilakukan sebanyak empat kali dan diuji di laboratoriumterhadap parameter pH, kekeruhan, Pb terlarut dan E.Col...

  17. Performance of an H-Darrieus in the skewed flow on a roof

    NARCIS (Netherlands)

    Mertens, S.; Kuik, van G.A.M.; Bussel, van G.J.W.

    2003-01-01

    Application of wind turbines on roofs of higher buildings is a subject of increasing interest. However, the wind conditions at the roof are complex and suitable wind turbines for this application are not yet developed. This paper addresses both issues: the wind conditions on the roof and the

  18. Wind loads on stand-off photovoltaic systems on pitched roofs

    NARCIS (Netherlands)

    Geurts, C.P.W.; Blackmore, P.A.

    2013-01-01

    Stand-off photovoltaic systems are a popular measure for retrofitting of existing pitched roofs. Panels are generally mounted parallel to the existing roof coverings, usually roofing tiles. Full scale and wind tunnel experiments have been performed to determine the net uplift loads on these systems,

  19. Solutions for Creating the Main Elements which Condition the Energy Consumption. Exterior Windows - Roof

    OpenAIRE

    Rubnicu, Alin

    2013-01-01

    The envelope of the building often has a complex geometry in which a multitude of different sub-assemblies can be identified. The envelope elements specific to roof areas can generally be of three types: walk and non-walk terrace roof as well as roof truss. The exterior joinery analysed is PVC type with four glass sheets.

  20. Evaluation of Green Roof Plants and Materials for Semi-Arid Climates

    Science.gov (United States)

    Abstract While green roof systems have proven to be highly effective in the evaporative cooling of buildings, reduction of roof top temperatures, protection of roof membranes from solar radiation degradation, reducing stormwater runoff, as well as beautification of the urban roo...

  1. Evaluation of Green Roof Water Quantity and Quality Performance in an Urban Climate

    Science.gov (United States)

    In this report we present an analysis of water benefits from an array of observed green roof and control (non-vegetated) roof project sites throughout NYC. The projects are located on a variety of building sites and represent a diverse set of available extensive green roof instal...

  2. Green roof systems: a study of public attitudes and preferences in southern Spain.

    Science.gov (United States)

    Fernandez-Cañero, Rafael; Emilsson, Tobias; Fernandez-Barba, Carolina; Herrera Machuca, Miguel Ángel

    2013-10-15

    This study investigates people's preconceptions of green roofs and their visual preference for different green roof design alternatives in relation to behavioral, social and demographical variables. The investigation was performed as a visual preference study using digital images created to represent eight different alternatives: gravel roof, extensive green roof with Sedums not in flower, extensive green roof with sedums in bloom, semi-intensive green roof with sedums and ornamental grasses, semi-intensive green roof with shrubs, intensive green roof planted with a lawn, intensive green roof with succulent and trees and intensive green roof with shrubs and trees. Using a Likert-type scale, 450 respondents were asked to indicate their preference for each digital image. Results indicated that respondents' sociodemographic characteristics and childhood environmental background influenced their preferences toward different green roof types. Results also showed that green roofs with a more careful design, greater variety of vegetation structure, and more variety of colors were preferred over alternatives. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Green Roofs: A Part of Green Infrastructure Strategy for Urban Areas

    Science.gov (United States)

    This is a presentation on the basics of green roof technology. The presentation highlights some of the recent ORD research projects on green roofs and provides insight for the end user as to the benefits for green roof technology. It provides links to currently available EPA rep...

  4. Who governs climate adaptation? Getting green roofs for stormwater retention off the ground

    NARCIS (Netherlands)

    Mees, H.L.P.; Driessen, P.P.J.; Runhaar, H.A.C.; Stamatelos, J.

    2013-01-01

    Green roofs are an innovative solution for urban stormwater management. This paper examines governance arrangements for green roofs as a ‘no-regrets’ climate adaptation measure in five cities. We analysed who governs green roofs, why and with what outcome. Our results show that hierarchical and

  5. 30 CFR 75.209 - Automated Temporary Roof Support (ATRS) systems.

    Science.gov (United States)

    2010-07-01

    ... of temporary support shall be used, as specified in the roof control plan, when— (1) Mining... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automated Temporary Roof Support (ATRS) systems... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Roof Support § 75.209...

  6. Ground water pollution by roof runoff infiltration evidenced with multi-tracer experiments.

    Science.gov (United States)

    Ammann, Adrian A; Hoehn, Eduard; Koch, Sabine

    2003-03-01

    The infiltration of urban roof runoff into well permeable subsurface material may have adverse effects on the ground water quality and endanger drinking water resources. Precipitation water from three different roofs of an industrial complex was channelled to a pit and infiltrated into a perialpine glaciofluvial gravel-and-sand aquifer. A shaft was constructed at the bottom of the pit and equipped with an array of TDR probes, lysimeters and suction cups that allowed measuring and sampling soil water at different depths. A fast infiltration flow was observed during natural rainfall events and during artificial infiltration experiments. For a better understanding of the behaviour of contaminants, experiments were conducted with cocktails of compounds of different reactivity (ammonium, strontium, atratone) and of non-reactive tracers (uranine, bromide, naphthionate), which represent different classes of pollutants. The experiment identified cation exchange reactions influencing the composition of the infiltrating water. These processes occurred under preferential flow conditions in macropores of the material. Measuring concentration changes under the controlled inflow of tracer experiments, the pollution potential was found to be high. Non-reactive tracers exhibited fast breakthrough and little sorption.

  7. Urban reconciliation ecology: the potential of living roofs and walls.

    Science.gov (United States)

    Francis, Robert A; Lorimer, Jamie

    2011-06-01

    Reconciling human and non-human use of urban regions to support biological conservation represents a major challenge for the 21st century. The concept of reconciliation ecology, by which the anthropogenic environment may be modified to encourage non-human use and biodiversity preservation without compromising societal utilization, potentially represents an appropriate paradigm for urban conservation given the generally poor opportunities that exist for reserve establishment and ecological restoration in urban areas. Two habitat improvement techniques with great potential for reconciliation ecology in urban areas are the installation of living roofs and walls, which have been shown to support a range of taxa at local scales. This paper evaluates the reconciliation potential of living roofs and walls, in particular highlighting both ecological and societal limitations that need to be overcome for application at the landscape scale. We further consider that successful utilization of living roofs and walls for urban reconciliation ecology will rely heavily on the participation of urban citizens, and that a 'citizen science' model is needed to facilitate public participation and support and to create an evidence base to determine their effectiveness. Living roofs and walls are just one aspect of urban reconciliation ecology, but are particularly important 'bottom-up' techniques for improving urban biodiversity that can be performed directly by the citizenry. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Opportunities Green Roofs Can Offer Ghanaians and their Cities

    African Journals Online (AJOL)

    Lone Star College System

    2015-08-17

    Aug 17, 2015 ... rising faster than the daily maximum thereby decreasing the comfort index of city dwellers. Electricity ... also on the rise. Green roofs have ..... by 6%. In Central Florida in the U.S., Cummings et al. .... levels, provision of habitat for animals and plants and .... representation of the Mediterranean Sea. Bull.

  9. variability of rainwater quality due to roof characteristics

    African Journals Online (AJOL)

    water. Although, some people typically consume collected rainwater without any type of ... variability of rain water quality due to roof characteristics was investigated using ... coverage of potable water, water supply still lags ... in getting projects executed; lack of adequate ... deterioration and its effects on health are scarce.

  10. Green Roof Research through EPA's Regional Applied Research Effort - slides

    Science.gov (United States)

    The U.S. Environmental Protection Agency’s (EPA) Regional Applied Research Effort (RARE) allows the Regions of the EPA to choose research projects to be performed in partnership with EPA’s Office of Research and Development (ORD). Over the last decade, several green roof projects...

  11. Roofing: Workbook and Tests. First-Aid Training.

    Science.gov (United States)

    California State Dept. of Education, Sacramento. Bureau of Publications.

    This workbook on first aid is one of a series of nine individual units of instruction for roofing apprenticeship classes in California. The workbook covers 12 topics: introduction to first-aid practices; burns; skeletal injuries; spinal injuries; wounds, bleeding, and bruises; emergencies of the heart and blood circulation system; breathing and…

  12. Impedance deduction for vegetated roof surfaces : multiple geometry strategy

    NARCIS (Netherlands)

    Liu, C.; Hornikx, M.

    2016-01-01

    The transfer function method is an efficient procedure to deduce the ground surface impedance from short-range propagation measurements using one point source. It is able to provide a reasonable prediction of the surface impedance of a vegetated roof as well, and the characteristics of the vegetated

  13. Green roofs: A possible best management practice for enhancing ...

    African Journals Online (AJOL)

    City expansion typically erodes the natural ability of the locale to perform its ecosystem services. This paper discusses green roofs and their potential benefits for Ghanaian cities in terms of improving environmental quality. Limited analysis shows that daily minimum temperatures of cities like Accra are rising faster than the ...

  14. Powered roof supports today - and tomorrow. [2 refs

    Energy Technology Data Exchange (ETDEWEB)

    Shepherd, R

    1977-02-01

    Coalface support has progressed considerably since the days when the first, then revolutionary, hydraulic and mechanical sliding props were introduced to supplant timber and rigid steel, and as each week passes the methods and the equipment now used seem to get more sophisticated. An explanation is presented on how newer designs of powered roof support are being developed to meet the latest challenges.

  15. Fire-induced reradiation underneath photovoltaic arrays on flat roofs

    DEFF Research Database (Denmark)

    Kristensen, Jens Steemann; Merci, Bart; Jomaas, Grunde

    2018-01-01

    The impact of the reflection of fire-induced heat from a gas burner was studied experimentally to gain knowledge on the interaction between photovoltaic (PV) panels and a fire on flat roofs. The heat flux was measured in a total of eight points at the same level as the top of the gas burner. The ...

  16. Asphalt and Wood Shingling. Roofing Workbook and Tests.

    Science.gov (United States)

    Brown, Arthur

    This combination workbook and set of tests contains materials on asphalt and wood shingling that have been designed to be used by those studying to enter the roofing and waterproofing trade. It consists of seven instructional units and seven accompanying objective tests. Covered in the individual units are the following topics: shingling…

  17. 30 CFR 75.221 - Roof control plan information.

    Science.gov (United States)

    2010-07-01

    ... installation and spacing of supports for each method of mining used. (6) When an ATRS system is used, the... of pillar recovery, and the sequence of mining pillars. (9) A list of all support materials required... mining approaches within 150 feet of an outcrop. (12) A description of the roof and rib support necessary...

  18. Green roofs'retention performances in different climates

    Science.gov (United States)

    Viola, Francesco; Hellies, Matteo; Deidda, Roberto

    2017-04-01

    The ongoing process of global urbanization contributes to increasing stormwater runoff from impervious surfaces, threatening also water quality. Green roofs have been proved to be an innovative stormwater management tool to partially restore natural state, enhancing interception, infiltration and evapotranspiration fluxes. The amount of water that is retained within green roofs depends mainly on both soil properties and climate. The evaluation of the retained water is not trivial since it depends on the stochastic soil moisture dynamics. The aim of this work is to explore performances of green roofs, in terms of water retention, as a function of their depth considering different climate regimes. The role of climate in driving water retention has been mainly represented by rainfall and potential evapotranspiration dynamics, which are simulated by a simple conceptual weather generator at daily time scale. The model is able to describe seasonal (in-phase and counter-phase) and stationary behaviors of climatic forcings. Model parameters have been estimated on more than 20,000 historical time series retrieved worldwide. Exemplifying cases are discussed for five different climate scenarios, changing the amplitude and/or the phase of daily mean rainfall and evapotranspiration forcings. The first scenario represents stationary climates, in two other cases the daily mean rainfall or the potential evapotranspiration evolve sinusoidally. In the latter two cases, we simulated the in-phase or in counter-phase conditions. Stochastic forcings have been then used as an input to a simple conceptual hydrological model which simulate soil moisture dynamics, evapotranspiration fluxes, runoff and leakage from soil pack at daily time scale. For several combinations of annual rainfall and potential evapotranspiration, the analysis allowed assessing green roofs' retaining capabilities, at annual time scale. Provided abacus allows a first approximation of possible hydrological benefits

  19. Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Kohta [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lstiburek, Joseph W. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    Insulating roofs with dense-pack cellulose (instead of spray foam) has moisture risks, but is a lower cost approach. If moisture risks could be addressed, buildings could benefit from retrofit options, and the ability to bring HVAC systems within the conditioned space. Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a control vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except the vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a diffusion vent detail, capped with vapor permeable roof membrane. Some ridge sections were built as a conventional unvented roof, as a control. In the control unvented roofs, roof peak RHs reached high levels in the first winter; as exterior conditions warmed, RHs quickly fell. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

  20. Quality of Coated Particles : Physical - Mechanical Characterization of Polymeric Film Coatings

    NARCIS (Netherlands)

    Perfetti, G.

    2012-01-01

    All coated particle producers, when applying the coating layer(s) would like to know precisely what is the best coating system to use in order to answer customer’s requests. It is, therefore, of very high relevance for many industries, to have a clear understanding of what are the parameters I need

  1. Quantitative Image Analysis for Evaluating the Coating Thickness and Pore Distribution in Coated Small Particles

    NARCIS (Netherlands)

    Laksmana, F.L.; Van Vliet, L.J.; Hartman Kok, P.J.A.; Vromans, H.; Frijlink, H.W.; Van der Voort Maarschalk, K.

    2008-01-01

    Purpose This study aims to develop a characterization method for coating structure based on image analysis, which is particularly promising for the rational design of coated particles in the pharmaceutical industry. Methods The method applies the MATLAB image processing toolbox to images of coated

  2. Quantitative Image Analysis for Evaluating the Coating Thickness and Pore Distribution in Coated Small Particles

    NARCIS (Netherlands)

    Laksmana, F L; Van Vliet, L J; Hartman Kok, P J A; Vromans, H; Frijlink, H W; Van der Voort Maarschalk, K

    This study aims to develop a characterization method for coating structure based on image analysis, which is particularly promising for the rational design of coated particles in the pharmaceutical industry. The method applies the MATLAB image processing toolbox to images of coated particles taken

  3. A Case Study of Effective Support Working Resistance and Roof Support Technology in Thick Seam Fully-Mechanized Face Mining with Hard Roof Conditions

    Directory of Open Access Journals (Sweden)

    Wei-bin Guo

    2017-06-01

    Full Text Available This paper presents the engineering geological properties and roof control tecnology for a thick coal seam fully-mechanized face mining with hard roof conditions (THC at the Jinhuagong Coal Mine (JCM, northwest China. The effective support working resistance and appropriate roof control technology are two critical factors for safe and productive mining in the THC. The load-estimate-method (LOEM is the effective method to determine the support working resistance for normal working conditions (the mining height less than 3.5 m. In order to prevent support crushing accidents from happening and to ensure the safety and high-efficiency in the THC, the LOEM was modified based on the structure of the overlying strata in the THC. The strata which can form the voussoir beam structure in normal working conditions and will break in the form of cantilever beam in the THC is defined as the key strata in the immediate roof. Therefore, the hanging length of the key strata in the immediate roof was considered in the LOEM. Furthermore, a method for calculating the hanging length of the key strata in the immediate roof and its influencing factors were proposed using cantilever beam theory analysis of the structure of the overlying strata. Moreover, in order to fully fill the goaf area with caving roof to reduce the energy accumulation of main roof movement, it was decided to apply destress blasting technique (DEBT at the JCM to control the large hanging length of the hard roof, so as to reduce the impact of the hard main roof movement on the working face. The key technique parameters of the roof caving borehole were also proposed. The obtained results demonstrated that the theoretical analysis is reasonable, and the chosen support type and the DEBT could meet the roof control requirements. The THC has achieved safety and high-efficiency mining.

  4. Measurement of Thermal Properties of Growing Media for Green Roofs: Assessment of a Laboratory Procedure and Experimental Results

    Directory of Open Access Journals (Sweden)

    Benedetta Barozzi

    2017-10-01

    Full Text Available While the Italian standard UNI 11235:2015 establishes minimum performance criteria, the thermal resistance of the growing medium of green roofs is not included in national regulations. Instead, thermal transmittance limits for roofs are obtained by referring to other stratigraphic layers. In the absence of specific national and international standards for laboratory calculations of the thermal performance of growing media for green roofs, a multi-year laboratory testing campaign was carried out on 8 samples which aimed to define the thermal resistance reference values of growing media as a function of density and water content. Thermal conductivity varies between 0.046–0.179 W/mK for dry samples as a function of density and between 0.046–0.47 W/mK as a function of moisture content. Defining a reference method, laboratory tests and restitution of the output in performance curves, was based on 108 tests carried out according to and deviating from the standard based on both guarded hot plate and heat flow meter methods. The significance of the results has prompted researchers and industrial partners to engage in further investment and ongoing tests in this area, targeting the definition of a standard laboratory method to be presented worldwide.

  5. The “shape” and “meaning” of the roof arts in Chinese classical architecture

    Science.gov (United States)

    Li, Xianda; liu, Yu

    2017-04-01

    This paper takes the “roof” in Chinese classical architecture as the research object. The breakthrough point of this paper would be the perspective of design aesthetics. Through the rational and perceptual analysis of the roof art, this paper would reveal that the roof shape has the double artistic features: “beauty of shape” and “beauty of idea”. This paper would have a comprehensive analysis for the following aspects: the rational method of roof construction, the emotional feeling of the roof construction and the implied meaning of beauty in the roof construction.

  6. Load test of the 3701U Building roof deck and support structure

    International Nuclear Information System (INIS)

    McCoy, R.M.

    1994-01-01

    The 3701U Building roof area was load tested according to the approved load-test procedure. The 3701U Building is located in the 300 Area of the Hanford Site and has the following characteristics: Roof deck--metal decking supported by steel purlins; Roof membrane--tar and gravel; Roof slope--flat (<10 deg); and Roof elevation--height of about 12.5 ft. The 3701U Building was visited in August 1992 for a visual inspection, but because of insulation an inspection could not be performed. The building was revisited in March 1994 for the purpose of writing this test report. Because the roof could not be inspected, a test was determined to be the best way to qualify the roof for personnel access. The test procedure called for the use of a remotely-controlled robot. The conclusions are that the roof has been qualified for 500-lb total roof load and that the ''No Roof Access'' signs can be changed to ''Roof Access Restricted'' signs

  7. Quantitative analysis on the urban flood mitigation effect by the extensive green roof system

    International Nuclear Information System (INIS)

    Lee, J.Y.; Moon, H.J.; Kim, T.I.; Kim, H.W.; Han, M.Y.

    2013-01-01

    Extensive green-roof systems are expected to have a synergetic effect in mitigating urban runoff, decreasing temperature and supplying water to a building. Mitigation of runoff through rainwater retention requires the effective design of a green-roof catchment. This study identified how to improve building runoff mitigation through quantitative analysis of an extensive green-roof system. Quantitative analysis of green-roof runoff characteristics indicated that the extensive green roof has a high water-retaining capacity response to rainfall of less than 20 mm/h. As the rainfall intensity increased, the water-retaining capacity decreased. The catchment efficiency of an extensive green roof ranged from 0.44 to 0.52, indicating reduced runoff comparing with efficiency of 0.9 for a concrete roof. Therefore, extensive green roofs are an effective storm water best-management practice and the proposed parameters can be applied to an algorithm for rainwater-harvesting tank design. -- Highlights: •Urban extensive green roof systems have a synergetic effect in mitigating urban runoff. •These systems are improve runoff mitigation and decentralized urban water management. •These systems have a high water-retaining capacity response to rainfall of less than 20 mm/h. •The catchment efficiency of an extensive green roof ranged from 0.44 to 0.52. -- Extensive green-roofs are an effective storm water best-management practice and the proposed parameters can be applied to mitigate urban runoff

  8. Assessment of green roof systems in terms of water and energy balance

    Directory of Open Access Journals (Sweden)

    Mert Ekşi

    2016-01-01

    Full Text Available Green roofs concept term is used for extensive green roofs which are planted with herbaceous plants that can be adapted into changeable environmental conditions on a shallow substrate layer, require minimal maintenance, installed for their benefits to building and urban scale. Main objective of this study is to determine the characteristics of a green roof such as thermal insulation, water holding capacity, runoff characteristics, plant growth and its interaction with environmental factors in Istanbul climate conditions by performing comparative measurements. In this study, a research site (IU Green Roof Research Station was founded to assess water and energy balance of green roofs. Thus, a typical green roof was evaluated in terms of water and energy balance and its interaction with the building and city was determined. energy efficiency of green roof system was 77% higher than reference roof. Temperature fluctuations on green roof section of the roof were 79% lower. In addition, green roof retained 12,8% - 100% of precipitation and delayed runoff up to 23 hours depending on water content of substrate.

  9. Load test of the 277W Building high bay roof deck and support structure

    International Nuclear Information System (INIS)

    McCoy, R.M.

    1994-01-01

    The 277W Building high bay roof area was load tested according to the approved load-test procedure, WHC-SD-GN-TP-30015, Revision 1. The 277W Building is located in the 200 West Area of the Hanford Site and has the following characteristics: roof deck -- wood decking supported by 4 x 14 timber purlins; roof membrane -- tar and gravel; roof slope -- flat (<10 deg); and roof elevation -- maximum height of about 63 ft. The 227W Building was visited in March 1994 for a visual inspection. During this inspection, cracked areas were visible in the decking, but it was not possible to determine whether these cracks extended completely through the decking, which is 2-in. thick. The building was revisited in March 1994 for the purpose of writing this test report. Because the roof requires personnel access, a test was determined to be the best way to qualify the roof. The conclusions are that the roof has been qualified for 500-lb total roof load and that the ''No Roof Access'' signs can be changed to ''Roof Access Restricted'' signs

  10. Monitoring of the Green Roofs Installation in Brno-City District, Czech Republic

    Science.gov (United States)

    Rebrova, Tatiana; Beckovsky, David; Selnik, Petr

    2017-12-01

    In spite of the rapidly growing interest to the green roofs, there is insufficient information about their local quantities and areas in Czech Republic as well as in Central Europe. There is a lack of technical information that leads to the further development, application and environmental contribution of green roofs under local climatic conditions. The purpose of the research is to follow the tendency of how the process of green roofs’ popularization is performed in the Czech Republic and to determine basic parameters of the installed green roofs. These parameters include total quantity, area and the most common roof vegetation type (extensive or intensive); how many green roofs were installed over the last years and as a result, how the proportion of the green roofs to the conventional ones is changing. For initial evaluation Brno-City District was chosen as the next stage of university environmental project EnviHUT following the genesis of green roofs under local weather conditions.

  11. Adsorption of *sp134*Cs onto two different types of roof materials

    International Nuclear Information System (INIS)

    Quenild, C.; Tveten, U.

    1983-01-01

    The report relates to a subproject under a Nordic project called ''Large reactor accidents - consequences and mitigating actions''. Natural decontamination of two types of roof material, typical of Norwegian and Swedish buildings, was examined. The roofs were contaminated with *sp134*Cs. After two days with 7 mm precipitation, the remaining activity on the tar-paper roof was 97% and on the steel roof 29%. After 8 months the remaining activity was 61% on the tar-paper roof and 22% on the steel roof. In spring *sp134*Cs was spread upon an 8 cm thick layer of fresh snow on an additional tar-paper roof. After 3 montsh and 191 mm precipitation the remaining activity was 59%. All results are based upon *sp134*Cs in collected run-off water.(Auth.)

  12. Experimental research on coalbed gas drainage effect and economy of long directional borehole in roof

    Science.gov (United States)

    Yang, Huiming; Hu, Liangping

    2017-05-01

    In order to study the coalbed gas drainage effect and economy of long directional roof borehole, 2 boreholes were laid out in Xinji No. 2 mine to analyze its gas drainage and investment costs comparing with high position roof borehole and high position roof roadway. The result indicates that the long directional roof borehole save investment by 44.8% and shorten the construction period by 30%, comparing with high position roof roadway for controlling gas in the working face. Investment slightly less and shorten the construction period by 47.5%, comparing with the roof high position borehole. Therefore, the method of the long directional roof borehole to drain coalbed gas in working face is the most cost-effective.

  13. Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. W. [Building Science Corporation, Westford, MA (United States)

    2016-02-01

    This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design.

  14. 49 CFR 571.118 - Standard No. 118; Power-operated window, partition, and roof panel systems.

    Science.gov (United States)

    2010-10-01

    ...-operated window, partition, and roof panel systems. S1. Purpose and scope. This standard specifies requirements for power operated window, partition, and roof panel systems to minimize the likelihood of death... Figure 2. Power operated roof panel systems mean moveable panels in the vehicle roof which close by...

  15. Thermal performances of ETFE cushion roof integrated amorphous silicon photovoltaic

    International Nuclear Information System (INIS)

    Hu, Jianhui; Chen, Wujun; Qiu, Zhenyu; Zhao, Bing; Zhou, Jinyu; Qu, Yegao

    2015-01-01

    Highlights: • Thermal performances of a three layer ETFE cushion integrated a-Si PV is evaluated. • Temperature of a-Si PV obviously affects temperature field and temperature boundary. • The maximum temperature difference of 3.4 K between measured and numerical results. • Main transport mechanisms in upper and lower chambers are convection and conduction. • Heat transfer coefficients of this roof are less than those of other ETFE cushion roofs. - Abstract: Thermal performances of the ETFE cushion roof integrated amorphous silicon photovoltaic (a-Si PV) are essential to estimate building performances, such as temperature distribution and heat transfer coefficient. To investigate these thermal performances, an experimental mock-up composed of a-Si PV and a three-layer ETFE cushion roof was built and the experiment was carried out under summer sunny condition. Meanwhile, numerical model with real boundary conditions was performed in this paper. The experimental results show that the temperature sequence of the three layers was the middle, top and bottom layer and that the PV temperature caused by solar irradiance was 353.8 K. This gives evidence that the PV has a significant effect on the temperature distribution. The experimental temperature was in good agreement with the corresponding location of the numerical temperature since the maximum temperature difference was only 3.4 K. Therefore, the numerical results were justified and then used to analyze the airflow characteristics and calculate the thermal performances. For the airflow characteristics, it is found that the temperature distribution was not uniform and the main transport mechanisms in the upper and lower chambers formed by the three layers were the convection and conduction, respectively. For the thermal performances, the surface convective heat transfer coefficients were obtained, which have validated that thermal performances of the three-layer ETFE cushion integrated a-Si PV are better than

  16. Green roof impact on the hydrological cycle components

    Science.gov (United States)

    Lamera, Carlotta; Rulli, Maria Cristina; Becciu, Gianfranco; Rosso, Renzo

    2013-04-01

    In the last decades the importance of storm water management in urban areas has increased considerably, due to both urbanization extension and to a greater concern for environment pollution. Traditional storm water control practices, based on the "all to the sewer" attitude, rely on conveyance to route storm water runoff from urban impervious surfaces towards the nearby natural water bodies. In recent years, infiltration facilities are receiving an increasing attention, due to their particular efficiency in restoring a balance in hydrological cycle quite equal to quite pre-urbanization condition. In particular, such techniques are designed to capture, temporarily retain and infiltrate storm water, promote evapotranspiration and harvest water at the source, encouraging in general evaporation, evapotranspiration, groundwater recharge and the re-use of storm water. Green roofs are emerging as an increasingly popular Sustainable Urban Drainage Systems (SUDS) technique for urban storm water management. Indeed, they are able to operate hydrologic control over storm water runoff: they allow a significant reduction of peak flows and runoff volumes collected by drainage system, with a consequent reduction of flooding events and pollution masses discharges by CSO. Furthermore green roofs have a positive influence on the microclimate in urban areas by helping in lower urban air temperatures and mitigate the heat island effect. Last but not least, they have the advantage of improving the thermal insulation of buildings, with significant energy savings. A detailed analysis of the hydrological dynamics, connected both with the characteristics of the climatic context and with the green roof technical design, is essential in order to obtain a full characterization of the hydrologic behavior of a green roof system and its effects on the urban water cycle components. The purpose of this paper is to analysis the hydrological effects and urban benefits of the vegetation cover of a

  17. Soft Roof Failure Mechanism and Supporting Method for Gob-Side Entry Retaining

    Directory of Open Access Journals (Sweden)

    Hongyun Yang

    2015-10-01

    Full Text Available To study the soft roof failure mechanism and the supporting method for a gateway in a gently inclined coal seam with a dip angle of 16° kept for gob-side entry retaining, and through the methodology of field investigation and numerical and analytical modeling, this paper analyzed the stress evolution law of roof strata at the working face end and determined that the sharp horizontal stress unloading phenomenon along the coal wall side did not appear after the working face advanced. Conversely, the horizontal stress along the gob side instantly decreased and the tensile stress produced, and the vertical stress in the central part of the roof had a higher reduction magnitude as well. An in-depth study indicates that the soft roof of the working face end subsided and seriously separated due to the effect of the front abutment pressure and the roof hanging length above the gob line, as well as certain other factors, including the rapid unloading of the lateral stress, tension and shear on the lower roof rock layer and dynamic disturbance. Those influencing factors also led to rapid crack propagation on a large scale and serious fracturing in the soft roof of the working face end. However, in the gob stress stabilized zone, the soft roof in the gob-side entry retaining has a shearing failure along the filling wall inside affected by the overburden pressure, rock bulking pressure, and roof gravity. To maintain the roof integrity, decrease the roof deformation, and enable the control of the working face end soft roof and the stabilization of the gob-side entry retaining roof, this study suggests that the preferred bolt installation angle for the soft roof situation is 70° based on the rock bolt extrusion strengthening theory.

  18. The effect of roofing material on the quality of harvested rainwater.

    Science.gov (United States)

    Mendez, Carolina B; Klenzendorf, J Brandon; Afshar, Brigit R; Simmons, Mark T; Barrett, Michael E; Kinney, Kerry A; Kirisits, Mary Jo

    2011-02-01

    Due to decreases in the availability and quality of traditional water resources, harvested rainwater is increasingly used for potable and non-potable purposes. In this study, we examined the effect of conventional roofing materials (i.e., asphalt fiberglass shingle, Galvalume(®) metal, and concrete tile) and alternative roofing materials (i.e., cool and green) on the quality of harvested rainwater. Results from pilot-scale and full-scale roofs demonstrated that rainwater harvested from any of these roofing materials would require treatment if the consumer wanted to meet United States Environmental Protection Agency primary and secondary drinking water standards or non-potable water reuse guidelines; at a minimum, first-flush diversion, filtration, and disinfection are recommended. Metal roofs are commonly recommended for rainwater harvesting applications, and this study showed that rainwater harvested from metal roofs tends to have lower concentrations of fecal indicator bacteria as compared to other roofing materials. However, concrete tile and cool roofs produced harvested rainwater quality similar to that from the metal roofs, indicating that these roofing materials also are suitable for rainwater harvesting applications. Although the shingle and green roofs produced water quality comparable in many respects to that from the other roofing materials, their dissolved organic carbon concentrations were very high (approximately one order of magnitude higher than what is typical for a finished drinking water in the United States), which might lead to high concentrations of disinfection byproducts after chlorination. Furthermore the concentrations of some metals (e.g., arsenic) in rainwater harvested from the green roof suggest that the quality of commercial growing media should be carefully examined if the harvested rainwater is being considered for domestic use. Hence, roofing material is an important consideration when designing a rainwater catchment. Copyright

  19. Self-Healing anticorrosive coatings

    DEFF Research Database (Denmark)

    Nesterova, Tatyana

    %. The number is lower than anticipated and needs to be confirmed. Finally, a 3-D model, based on Monte-Carlo simulations, has been developed for prediction of healing efficiency of a microcapsule-based anticorrosive coating. Two kinds of cracks were considered: cracks accommodated within the bulk coating...... associated with development and testing of this type of coating. A laboratory investigation, to identify the most suitable method for production of mechanically stable (filled with industrially relevant core materials) and forming a free-flowing powder upon drying microcapsules, has been performed. Four...... reduces the intensity of crack formation (both in number and length) compared to filler-containing coatings and prevents the coating from flaking upon damage. Based on specular gloss measurements, a preliminary critical pigment (microcapsule) concentration (CPVC) value was estimated to about 30 vol...

  20. A dual response surface optimization methodology for achieving uniform coating thickness in powder coating process

    Directory of Open Access Journals (Sweden)

    Boby John

    2015-09-01

    Full Text Available The powder coating is an economic, technologically superior and environment friendly painting technique compared with other conventional painting methods. However large variation in coating thickness can reduce the attractiveness of powder coated products. The coating thickness variation can also adversely affect the surface appearance and corrosion resistivity of the product. This can eventually lead to customer dissatisfaction and loss of market share. In this paper, the author discusses a dual response surface optimization methodology to minimize the thickness variation around the target value of powder coated industrial enclosures. The industrial enclosures are cabinets used for mounting the electrical and electronic equipment. The proposed methodology consists of establishing the relationship between the coating thickness & the powder coating process parameters and developing models for the mean and variance of coating thickness. Then the powder coating process is optimized by minimizing the standard deviation of coating thickness subject to the constraint that the thickness mean would be very close to the target. The study resulted in achieving a coating thickness mean of 80.0199 microns for industrial enclosures, which is very close to the target value of 80 microns. A comparison of the results of the proposed approach with that of existing methodologies showed that the suggested method is equally good or even better than the existing methodologies. The result of the study is also validated with a new batch of industrial enclosures.

  1. Bright is the New Black - Multi-Year Performance of Generic High-Albedo Roofs in an Urban Climate

    Science.gov (United States)

    Gaffin, S. R.; Imhoff, M.; Rosenzweig, C.; Khanbilvardi, R.; Pasqualini, A.; Kong, A. Y. Y.; Grillo, D.; Freed, A.; Hillel, D.; Hartung, E.

    2012-01-01

    High-albedo white and cool roofing membranes are recognized as a fundamental strategy that dense urban areas can deploy on a large scale, at low cost, to mitigate the urban heat island effect. We are monitoring three generic white membranes within New York City that represent a cross-section of the dominant white membrane options for U.S. flat roofs: (1) an ethylene propylene diene monomer (EPDM) rubber membrane; (2) a thermoplastic polyolefin (TPO) membrane and; (3) an asphaltic multi-ply built-up membrane coated with white elastomeric acrylic paint. The paint product is being used by New York City s government for the first major urban albedo enhancement program in its history. We report on the temperature and related albedo performance of these three membranes at three different sites over a multi-year period. The results indicate that the professionally installed white membranes are maintaining their temperature control effectively and are meeting the Energy Star Cool Roofing performance standards requiring a three-year aged albedo above 0.50. The EPDM membrane however shows evidence of low emissivity. The painted asphaltic surface shows high emissivity but lost about half of its initial albedo within two years after installation. Given that the acrylic approach is an important "do-it-yourself," low-cost, retrofit technique, and, as such, offers the most rapid technique for increasing urban albedo, further product performance research is recommended to identify conditions that optimize its long-term albedo control. Even so, its current multi-year performance still represents a significant albedo enhancement for urban heat island mitigation.

  2. Nanocrystalline diamond coatings for machining

    Energy Technology Data Exchange (ETDEWEB)

    Frank, M.; Breidt, D.; Cremer, R. [CemeCon AG, Wuerselen (Germany)

    2007-07-01

    This history of CVD diamond synthesis goes back to the fifties of the last century. However, the scientific and economical potential was only gradually recognized. In the eighties, intensive worldwide research on CVD diamond synthesis and applications was launched. Industrial products, especially diamond-coated cutting tools, were introduced to the market in the middle of the nineties. This article shows the latest developments in this area, which comprises nanocrystalline diamond coating structures. (orig.)

  3. Controlled Roof Collapse during Secondary Mining in Coal Mines

    Directory of Open Access Journals (Sweden)

    Ashleigh Hutchinson

    2012-01-01

    Full Text Available The problem considered is an investigation of the possible collapse of the roof between the pillar next to be mined in secondary coal mining and the first line of pillar remnants called snooks. The roof rock between the pillar, which is the working face, and the snook is modelled as an Euler-Bernoulli beam acted on at each end by a horizontal force and by its weight per unit length. The beam is clamped at the pillar and simply supported (hinged at the snook. The dimensionless differential equation for the beam and the boundary conditions depend on one dimensionless number . We consider the range of values of before the displacement and curvature first become singular at =1. The model predicts that for all practical purposes, the beam will break at the clamped end at the pillar. The failure of the beam for values of greater than 1 is investigated computationally.

  4. Weathering of radiocaesium contamination on urban streets, walls and roofs

    International Nuclear Information System (INIS)

    Andersson, K.G.; Roed, J.; Fogh, C.L.

    2002-01-01

    Recent investigations in Russia have emphasised the significance of dose contributions from contamination on urban streets and roof pavings, and, typically to a lesser extent, walls in the urban environment. The crucial factor determining the magnitude of these contributions is the retention of the contamination by the different types of urban surface. Since the Chernobyl accident, a series of long-term field studies has been carried out on urban streets, walls and roofs, to examine the weathering processes of 137 Cs on the various surface types. The derived time-functions are applied to estimate resultant long-term doses to inhabitants of an urban centre. The paper highlights the effect on caesium retention of surface material characteristics

  5. Modeling Košice Green Roofs Maps

    Science.gov (United States)

    Poorova, Zuzana; Vranayova, Zuzana

    2017-06-01

    The need to house population in urban areas is expected to rise to 66% in 2050, according to United Nations. The replacement of natural permeable green areas with concrete constructions and hard surfaces will be noticed. The densification of existing built-up areas is responsible for the decreasing vegetation, which results in the lack of evapotranspiration cooling the air. Such decreasing vegetation causes urban heat islands. Since roofs and pavements have a very low albedo, they absorb a lot of sunlight. Several studies have shown that natural and permeable surfaces, as in the case of green roofs, can play crucial role in mitigating this negative climate phenomenon and providing higher efficiency for the building, leading to savings. Such as water saving, what is the main idea of this research.

  6. Identifying city PV roof resource based on Gabor filter

    Science.gov (United States)

    Ruhang, Xu; Zhilin, Liu; Yong, Huang; Xiaoyu, Zhang

    2017-06-01

    To identify a city’s PV roof resources, the area and ownership distribution of residential buildings in an urban district should be assessed. To achieve this assessment, remote sensing data analysing is a promising approach. Urban building roof area estimation is a major topic for remote sensing image information extraction. There are normally three ways to solve this problem. The first way is pixel-based analysis, which is based on mathematical morphology or statistical methods; the second way is object-based analysis, which is able to combine semantic information and expert knowledge; the third way is signal-processing view method. This paper presented a Gabor filter based method. This result shows that the method is fast and with proper accuracy.

  7. Cost Effectiveness of Precast Reinforced Concrete Roof Slabs

    Science.gov (United States)

    Parskiy, N. D.; Molodtsov, M. V.; Molodtsova, V. E.

    2017-11-01

    Engineers always seek to free interior space from intermediate supporting elements. Nowadays plants, being at the forefront of technology, produce a new generation of exclusive patented prefabricated reinforced concrete elements with a high load-bearing capacity, excellent heat resistance characteristics combined with the aesthetics and beauty. It is a system of Seagull Gabbiano prestressed roof slabs for the spans of 12m - 40m. The article shows the advantages of the Seagull slabs over conventional precast reinforced concrete and metal roof trusses. It also gives the analysis of the technical and economic indices of design and construction of a building with the Seagull slabs depending on the size of spans to cover. The use of structural systems with increased spans allows for the modern buildings and structures of prefabricated reinforced concrete with enhanced functionality and aesthetics alongside with a wide range of planning solutions.

  8. Positive effects of vegetation: Urban heat island and green roofs

    International Nuclear Information System (INIS)

    Susca, T.; Gaffin, S.R.; Dell'Osso, G.R.

    2011-01-01

    This paper attempts to evaluate the positive effects of vegetation with a multi-scale approach: an urban and a building scale. Monitoring the urban heat island in four areas of New York City, we have found an average of 2 deg. C difference of temperatures between the most and the least vegetated areas, ascribable to the substitution of vegetation with man-made building materials. At micro-scale, we have assessed the effect of surface albedo on climate through the use of a climatological model. Then, using the CO 2 equivalents as indicators of the impact on climate, we have compared the surface albedo, and the construction, replacement and use phase of a black, a white and a green roof. By our analyses, we found that both the white and the green roofs are less impactive than the black one; with the thermal resistance, the biological activity of plants and the surface albedo playing a crucial role. - Highlights: → The local morphology and the scarcity of vegetation in NYC core determines its UHI. → We introduce the evaluation of the effects of the surface albedo on climate change. → We use it to compare a black roof with a white and a green one. → Surface albedo has a crucial role in the evaluation of the environmental loads of the roofs. → Vegetation has positive effects on both the urban and the building scale. - Vegetation has positive effects both on an urban scale, mitigating the urban heat island effect; and on a building scale, where albedo, thermal insulation and biological activity of plants play a crucial role.

  9. Quantifying the Lateral Bracing Provided by Standing Steam Roof Systems

    OpenAIRE

    Sorensen, Taylor J.

    2016-01-01

    One of the major challenges of engineering is finding the proper balance between economical and safe. Currently engineers at Nucor Corporation have ignored the additional lateral bracing provided by standing seam roofing systems to joists because of the lack of methods available to quantify the amount of bracing provided. Based on the results of testing performed herein, this bracing is significant, potentially resulting in excessively conservative designs and unnecessary costs. This proje...

  10. A modelling study of long term green roof retention performance.

    Science.gov (United States)

    Stovin, Virginia; Poë, Simon; Berretta, Christian

    2013-12-15

    This paper outlines the development of a conceptual hydrological flux model for the long term continuous simulation of runoff and drought risk for green roof systems. A green roof's retention capacity depends upon its physical configuration, but it is also strongly influenced by local climatic controls, including the rainfall characteristics and the restoration of retention capacity associated with evapotranspiration during dry weather periods. The model includes a function that links evapotranspiration rates to substrate moisture content, and is validated against observed runoff data. The model's application to typical extensive green roof configurations is demonstrated with reference to four UK locations characterised by contrasting climatic regimes, using 30-year rainfall time-series inputs at hourly simulation time steps. It is shown that retention performance is dependent upon local climatic conditions. Volumetric retention ranges from 0.19 (cool, wet climate) to 0.59 (warm, dry climate). Per event retention is also considered, and it is demonstrated that retention performance decreases significantly when high return period events are considered in isolation. For example, in Sheffield the median per-event retention is 1.00 (many small events), but the median retention for events exceeding a 1 in 1 yr return period threshold is only 0.10. The simulation tool also provides useful information about the likelihood of drought periods, for which irrigation may be required. A sensitivity study suggests that green roofs with reduced moisture-holding capacity and/or low evapotranspiration rates will tend to offer reduced levels of retention, whilst high moisture-holding capacity and low evapotranspiration rates offer the strongest drought resistance. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Long-term Deformation Measurements of Atypical Roof Timber Structures

    Directory of Open Access Journals (Sweden)

    Jiří Bureš

    2014-06-01

    Full Text Available The paper includes conclusions from evaluation of results obtained from long-termmeasuring of innovative atypical roof timber structures. Based on the results ofmeasurements of vertical and horizontal deformation components it is possible to analyzethe real behavior of structures in given conditions. By assessing deformations in variousstages, including particularly external and internal environment temperatures, relative airhumidity and moisture content of wood, decisive parameters for real structure behaviorcan be established. The data are processed from period 2001 – 2013.

  12. Building Integrated Photovoltaic (BIPV) Roofs for Sustainability and Energy Efficiency

    Science.gov (United States)

    2013-09-10

    288 Enviromental 1 - Main Membrane 90000 9043 SqFt 472 Ft 94 98 None Real Estate Perimeter: 460Ft Rating: Excellent Rating: Excellent...Cost Index: $2.00 Section: Section Area: 288- Building 288 Enviromental 1 9043 Roof Replacement Cost: Insulation Replacement Cost: $8.00 per...Bldg NoJSec: 2881 Bldg Name: Bui ding 288 Enviromental Bldg Use: Ofice Inspection Date: Oct/2011 Membrane: SINGLE-PlY: PVC Area (SF): 9043

  13. Superhard carbon film deposition by means of Laser-Arco {sup registered} on the way from the laboratory into the industrial series coating; Abscheidung superharter Kohlenstoffschichten mittels Laser-Arco {sup registered} auf dem Weg vom Labor in die industrielle Serienfertigung

    Energy Technology Data Exchange (ETDEWEB)

    Scheibe, Hans-Joachim; Leonhardt, Michael; Leson, Andreas; Meyer, Carl-Friedrich; Stucky, Thomas; Weihnacht, Volker [Fraunhofer-Institut fuer Werkstoff- und Strahltechnik (IWS), Dresden (Germany)

    2008-12-15

    Diamond-like carbon films (DLC) are more and more applied as wear protection coatings for components and tools due to their unique combination of high hardness, low friction and sticking tendency to metallic counter bodies. Up to now applied DLC films are hydrogen containing (a-C:H) or metal carbon films (Me-C:H) deposited by a plasma assisted CVD process from carbon-hydrogen gas mixtures. Their wide industrial effort results from that the can be deposited with slowly modified coating machines for classical hard coating (e.g. TiN or CrN). A new generation DLC films are the hydrogen-free ta-C films (ta-C = tetrahedral bounded amorphous carbon) with a between two and three-times higher hardness and with a resulting higher wear resistance under extreme condition than classical DLC films. They have excellent emergency running properties at lubrication break down. Their industrial application is more difficult due to that they cannot deposited with modified coating machines for classical hard and DLC coating and a new technology with corresponding equipment was not available up to now. The laser controlled, pulsed arc deposition technology (Laser-Arco {sup registered}) of the Fraunhofer IWS Dresden has this potential. In kind of a Laser-Arc-Module-source the ta-C film deposition can be integrated in every industrial used deposition machine. (orig.)

  14. Study of microstructure and mechanical properties of ceramics composites alumina-zirconia reinforced with yttria for inert coating of metal matrices used in the petroleum industry

    International Nuclear Information System (INIS)

    Pontual, J.O.; Silva, N.D.G.; Ferreira, R.A.S.; Yadava, Y.P.

    2014-01-01

    The storage and transportation of crude oil is complicated due to the hostile environment provided by this. Under these conditions, it is imperative to search for alternative solutions, using an inert coating to protect from corrosion caused by crude oil. In this work, alumina-zirconia ceramic composites with 5-20%w zirconia and 1 - 2%w yttria were produced through thermomechanical process. The structural and microstructural characterization of the sintered material was carried out by X-ray diffraction and scanning electron microscopy. Mechanical properties were analyzed by Vickers hardness tests. Currently, the pads are submerged in crude oil and after 30-60 days will be removed and sent for stability test.(author)

  15. Thermophysical aspects of reconstruction of cold roof spaces

    Directory of Open Access Journals (Sweden)

    Semko Oleksandr

    2017-01-01

    Full Text Available The results of theoretical studies of thermal modernization of cold roof floor. The designs of overlap of long-life roofs of public buildings were considered. Overlap of these buildings are made by wooden or concrete beams and made of concrete slabs with upward edges. The problems of thermal modernization of these designs are consideration of the impact of heat-conducting inclusions on the resistance to heat. The heat-conducting inclusions of constructions are beams and vertical edges of the slabs. The results of calculations of the temperature fields were used for the analysis. The research was carried for the two temperature zones which Ukraine’s territory is divided into. The analysis of thermal protection level of structures overlap was made. The magnitude of the impact of heat-conducting inclusions on resistance to heat after thermal modernization of cold roof floor was observed. The analysis showed that the thermal protection properties of structures less than standard, therefore the insulation of areas with heat-conducting inclusions is required. The options of insulation of these areas were considered. The optimal insulation options with the least amount of additional insulation over the heat conductive areas were selected.

  16. Roof slab cooling device in a FBR type reactor

    International Nuclear Information System (INIS)

    Tarutani, Kohei

    1987-01-01

    Purpose: To obtain a roof slab cooling device capable of retaining cooling performance even in a case of electric power supply stop or failure and effective from economical point of view. Constitution: Atmospheric air is introduced into the cooling chamber of a proof slab and spontaneously passed to a exit pipeway connected to a stack thereby cooling the roof slab. Specifically, atmospheric air entered from the inlet pipeway is introduced to the cooling chamber and absorbs heat generate from the inside of the reactor container. Warmed air is sucked from the exit pipeway and then released into the atmosphere passing through the stack. The air cools the roof slab during circulation due to spontaneous passage and keeps the slab at a low temperature. Since the air is passed spontaneously, no power such as for a blower is required at all and, if the electric power supply should be lost, the cooling power can be maintained as it is to provide a high reliability. Further, since no electric power is required for the blowing power, it has high economical merit. (Horiuchi, T.)

  17. Standard tests for the characterization of roofing slate pathologies

    Directory of Open Access Journals (Sweden)

    Cárdenes, V.

    2012-06-01

    Full Text Available The pathologies formed in slate roofs are mainly due to the presence of potentially unstable minerals (iron sulfides, carbonates and organic matter. These minerals may become altered by the effect of environmental agents, once the slate roof is finished. The pathologies are mainly associated with oxidation and gypsification processes of the cited mineral phases. In this work, the potential pathologies of several Spanish roofing slates are identified, using the tests defined in the European Norms EN 12326:2005, 14147:2004 and 11597:2007.

    Las patologías que se originan en pizarra para cubiertas son debidas fundamentalmente a la presencia de materiales alterables (sulfuros de hierro, carbonatos y materia orgánica. Estos minerales pueden llegar a alterarse por efecto de los agentes medioambientales, una vez que la pizarra es puesta en obra. Las patologías están principalmente asociadas a procesos de oxidación y yesificación de las citadas fases minerales. En este trabajo se determinan las patologías potenciales de varias pizarras para cubiertas españolas, utilizando los ensayos definidos en las normas UNE-EN 12326:2005, 14147:2004 y 11597:2007.

  18. A generic hydrological model for a green roof drainage layer.

    Science.gov (United States)

    Vesuviano, Gianni; Stovin, Virginia

    2013-01-01

    A rainfall simulator of length 5 m and width 1 m was used to supply constant intensity and largely spatially uniform water inflow events to 100 different configurations of commercially available green roof drainage layer and protection mat. The runoff from each inflow event was collected and sampled at one-second intervals. Time-series runoff responses were subsequently produced for each of the tested configurations, using the average response of three repeat tests. Runoff models, based on storage routing (dS/dt = I-Q) and a power-law relationship between storage and runoff (Q = kS(n)), and incorporating a delay parameter, were created. The parameters k, n and delay were optimized to best fit each of the runoff responses individually. The range and pattern of optimized parameter values was analysed with respect to roof and event configuration. An analysis was performed to determine the sensitivity of the shape of the runoff profile to changes in parameter values. There appears to be potential to consolidate values of n by roof slope and drainage component material.

  19. Retrofitted green roofs and walls and improvements in thermal comfort

    Science.gov (United States)

    Feitosa, Renato Castiglia; Wilkinson, Sara

    2017-06-01

    Increased urbanization has led to a worsening in the quality of life for many people living in large cities in respect of the urban heat island effect and increases of indoor temperatures in housing and other buildings. A solution may be to retrofit existing environments to their former conditions, with a combination of green infrastructures applied to existing walls and rooftops. Retrofitted green roofs may attenuate housing temperature. However, with tall buildings, facade areas are much larger compared to rooftop areas, the role of green walls in mitigating extreme temperatures is more pronounced. Thus, the combination of green roofs and green walls is expected to promote a better thermal performance in the building envelope. For this purpose, a modular vegetated system is adopted for covering both walls and rooftops. Rather than temperature itself, the heat index, which comprises the combined effect of temperature and relative humidity is used in the evaluation of thermal comfort in small scale experiments performed in Sydney - Australia, where identical timber framed structures prototypes (vegetated and non-vegetated) are compared. The results have shown a different understanding of thermal comfort improvement regarding heat index rather than temperature itself. The combination of green roof and walls has a valid role to play in heat index attenuation.

  20. Operation of roof pond systems, considering its advantages and disadvantages

    Energy Technology Data Exchange (ETDEWEB)

    Noohi, Samira; Rezaei, Davood [Faculty of engineering, Zanjan University (Iran, Islamic Republic of)], email: noohi.sam@gmail.com, email: d_rezaei@znu.ac.ir

    2011-07-01

    With the coming shortage of fossil fuels it is important to develop energy efficient buildings to reduce both energy consumption and pollution at the same time. The roof pond system is a passive solar system which gathers heat from the sun and can distribute it to the living space to cool it or heat it by changing the operating cycle. Although not recent, this method has not been widely implemented due to certain limitations and the aim of this paper is to assess the different advantages and disadvantages of this system over other passive solar heating systems. This study showed that a roof pond has a low impact on the building, provides controllable energy delivery and variations in indoor temperature are low; however it requires an active solar system as a backup and vegetation can limit sunlight penetration. This study highlighted that the efficiency of the roof system pond depends on climate conditions and that it is best suited to lower latitude and low humidity areas.

  1. Respirable quartz hazard associated with coal mine roof bolter dust

    International Nuclear Information System (INIS)

    Joy, G.J.; Beck, T.W.; Listak, J.M.

    2010-01-01

    Pneumoconiosis has been reported to be increasing among underground coal miners in the Southern Appalachian Region. The National Institute for Occupational Safety and Health conducted a study to examine the particle size distribution and quartz content of dust generated by the installation of roof bolts in mines. Forty-six bulk samples of roof bolting machine pre-cleaner cyclone dump dust and collector box dust were collected from 26 underground coal mines. Real-time and integrated airborne respirable dust concentrations were measured on 3 mining sections in 2 mines. The real-time airborne dust concentrations profiles were examined to identify any concentration changes that might be associated with pre-cleaner cyclone dust discharge events. The study showed that bolter dust is a potential inhalation hazard due to the fraction of dust less than 10 μm in size, and the quartz content of the dust. The pre-cleaner cyclone dust was significantly larger than the collector box dust, indicating that the pre-cleaner functioned properly in removing the larger dust size fraction from the airstream. However, the pre-cleaner dust still contained a substantial amount of respirable dust. It was concluded that in order to maintain the effectiveness of a roof bolter dust collector, periodic removal of dust is required. Appropriate work procedures and equipment are necessary to minimize exposure during this cleaning task. 13 refs., 3 tabs., 2 figs.

  2. Innovative Ballasted Flat Roof Solar PV Racking System

    Energy Technology Data Exchange (ETDEWEB)

    Peek, Richard T. [Cascade Engineering, Grand Rapids, MI (United States)

    2014-12-15

    The objective of this project was to reduce the cost of racking for PV solar on flat commercial rooftops. Cost reductions would come from both labor savings and material savings related to the installation process. The rack would need to accommodate the majority of modules available on the market. Cascade Engineering has a long history of converting traditional metal type applications over to plastic. Injection molding of plastics have numerous advantages including selection of resin for the application, placing the material exactly where it is needed, designing in features that will speed up the installation process, and weight reduction of the array. A plastic rack would need to meet the requirements of UL2703, Mounting systems, mounting devices, clamping/retention devices, and ground lugs for use with flat-plate photovoltaic modules and panels. Comparing original data to the end of project racking design, racking material costs were reduced 50% and labor costs reduced 64%. The racking product accommodates all 60 and 72 cell panels on the market, meets UL2703 requirements, contributes only 1.3 pounds per square foot of weight to the array, requires little ballast to secure the array, automatically grounds the module when the module is secured, stacks/nests well for shipping/fewer lifts to the roof, provides integrated wire routing, allows water to drain on the roof, and accommodates various seismic roof connections. Project goals were achieved as noted in the original funding application.

  3. Equilibrium thermal characteristics of a building integrated photovoltaic tiled roof

    Energy Technology Data Exchange (ETDEWEB)

    Mei, L.; Gottschalg, R.; Loveday, D.L. [Centre for Renewable Energy Systems Technology (CREST), Department of Electronic and Electrical Engineering, Loughborough University, Loughborough, Leicestershire, LE11 3TU (United Kingdom); Infield, D.G. [Institute of Energy and Environment, Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow, G1 1XW (United Kingdom); Davies, D.; Berry, M. [Solarcentury, 91-94 Lower Marsh Waterloo, London, SE1 7AB (United Kingdom)

    2009-10-15

    Photovoltaic (PV) modules attain high temperatures when exposed to a combination of high radiation levels and elevated ambient temperatures. The temperature rise can be particularly problematic for fully building integrated PV (BIPV) roof tile systems if back ventilation is restricted. PV laminates could suffer yield degradation and accelerated aging in these conditions. This paper presents a laboratory based experimental investigation undertaken to determine the potential for high temperature operation in such a BIPV installation. This is achieved by ascertaining the dependence of the PV roof tile temperature on incident radiation and ambient temperature. A theory based correction was developed to account for the unrealistic sky temperature of the solar simulator used in the experiments. The particular PV roof tiles used are warranted up to an operational temperature of 85 C, anything above this temperature will void the warranty because of potential damage to the integrity of the encapsulation. As a guide for installers, a map of southern Europe has been generated indicating locations where excessive module temperatures might be expected and thus where installation is inadvisable. (author)

  4. Global developments of controls of powered roof supports

    Energy Technology Data Exchange (ETDEWEB)

    Das, S.K. [Indian School of Mines, Dhanbad (India). Centre of Longwall Mine Mechanisation

    1996-04-01

    The efficiency of hydraulic powered roof support systems mainly depends upon the efficient control and operation of hydraulic valves and their associated accessories. From 1961 to 1994 tremendous efforts had been made for the development of higher and higher efficient, reliable but simpler control systems starting from the manual hydraulic to electro-hydraulic and finally computer based electronic control system. A global survey of development of various types and design of control systems of powered roof supports has been made and many of them are highlighted in the paper for making this work a small emblem regarding the efforts of development of the controls of powered roof support systems by the global engineers of the 20th century. Many of the control systems are no longer in use and have totally vanished from this earth and many more control systems including their literatures may vanish from this world in the coming decades. This work may give a guideline regarding the selection of right type of control systems for the powered supports in future. 14 refs., 6 figs.

  5. Theoretical and experimental studies on the daily accumulative heat gain from cool roofs

    International Nuclear Information System (INIS)

    Qin, Yinghong; Zhang, Mingyi; Hiller, Jacob E.

    2017-01-01

    Cool roofs are gaining popularity as passive building cooling techniques, but the correlation between energy savings and rooftop albedo has not been understood completely. Here we theoretically model the daily accumulative inward heat (DAIH) from building roofs with different albedo values, correlating the heat gain of the building roof to both the rooftop albedo and the incident solar radiation. According to this model, the DAIH increases linearly with the daily zenith solar radiation, but decreases linearly with the rooftop albedo. A small building cell was constructed to monitor the heat gain of the building under the conditions of non-insulated and insulated roofs. The observational DAIH is highly coincident with the theoretical one, validating the theoretical model. It was found that insulating the roof, increasing the rooftop albedo, or both options can effectively curtail the heat gain in buildings during the summer season. The proposed theoretical model would be a powerful tool for evaluating the heat gain of the buildings and estimating the energy savings potential of high-reflective cool roofs. - Highlights: • Daily accumulative heat gain from a building roof is theoretically modeled. • Daily accumulative heat gain from a building roof increases linearly with rooftop absorptivity. • Increasing the roof insulation tapers the effect of the rooftop absorptivity. • The theoretical model is powerful for estimating energy savings of reflective roofs.

  6. Nutrient leaching from extensive green roofs with different substrate compositions: a laboratory study.

    Science.gov (United States)

    Zhang, Wei; Zhong, Xing; Che, Wu

    2018-02-01

    To investigate nutrient leaching from extensive green roofs, green roof platforms were established to investigate the effluent quantity and quality during artificial rainfall. When the influent volume reached three times the empty bed volume, for which the cumulative rainfall was around 300 mm, the effluent TP and COD concentrations of green roof platforms filled with peat soil did not tend to stabilize. For a long-term operation, the substrate depths had little significant influence on TN, TP and COD concentrations of the green roof effluents. A normalized cumulative emission process method was proposed to discuss the difference in various pollutant leaching processes. Obvious differences in the leaching process of different contaminants for green roof platforms filled with various substrates were observed. For the green roof filled with modified substrates, the nitrogen and phosphorus pollutant leaching rates were relatively high in the initial stage of green roof operation and the phosphorus leaching rate was higher than that of nitrogen. The green roof is a sink for TN, but not for TP and COD in this study. The outcomes are critical for the selection of green roof substrates and also contribute to green roof maintenance.

  7. Impact of green roofs on stormwater quality in a South Australian urban environment.

    Science.gov (United States)

    Razzaghmanesh, M; Beecham, S; Kazemi, F

    2014-02-01

    Green roofs are an increasingly important component of water sensitive urban design systems and can potentially improve the quality of urban runoff. However, there is evidence that they can occasionally act as a source rather than a sink for pollutants. In this study, the water quality of the outflow from both intensive and extensive green roof systems were studied in the city of Adelaide, South Australia over a period of nine months. The aim was to examine the effects of different green roof configurations on stormwater quality and to compare this with runoff from aluminium and asphalt roofs as control surfaces. The contaminant concentrations in runoff from both intensive and extensive green roofs generally decreased during the study period. A comparison between the two types of green roof showed that except for some events for EC, TDS and chloride, the values of the parameters such as pH, turbidity, nitrate, phosphate and potassium in intensive green roof outflows were higher than in the outflows from the extensive green roofs. These concentrations were compared to local, state, national and international water quality guidelines in order to investigate the potential for outflow runoff from green roofs to be reused for potable and non-potable purposes. The study found that green roof outflow can provide an alternative water source for non-potable purposes such as urban landscape irrigation and toilet flushing. © 2013.

  8. Building America Case Study: Field Testing an Unvented Roof with Fibrous Insulation and Tiles, Orlando, Florida

    Energy Technology Data Exchange (ETDEWEB)

    2015-11-01

    This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design. The unvented roof had extended winter periods of 95-100% RH, and wafer (wood surrogate RH sensor) measurements indicating possible condensation; high moisture levels were concentrated at the roof ridge. In contrast, the diffusion vent roofs had drier conditions, with most peak MCs (sheathing) below 20%. In the spring, as outdoor temperatures warmed, all roofs dried well into the safe range (10% MC or less). Some roof-wall interfaces showed moderately high MCs; this might be due to moisture accumulation at the highest point in the lower attic, and/or shading of the roof by the adjacent second story. Monitoring will be continued at least through spring 2016 (another winter and spring).

  9. Field Testing of an Unvented Roof with Fibrous Insulation, Tiles and Vapor Diffusion Venting

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. W. [Building Science Corporation, Westford, MA (United States)

    2016-02-05

    This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design. The unvented roof had extended winter periods of 95-100% RH, and wafer (wood surrogate RH sensor) measurements indicating possible condensation; high moisture levels were concentrated at the roof ridge. In contrast, the diffusion vent roofs had drier conditions, with most peak MCs (sheathing) below 20%. In the spring, as outdoor temperatures warmed, all roofs dried well into the safe range (10% MC or less). Some roof-wall interfaces showed moderately high MCs; this might be due to moisture accumulation at the highest point in the lower attic, and/or shading of the roof by the adjacent second story. Monitoring will be continued at least through spring 2016 (another winter and spring).

  10. Structure and corrosion properties of PVD Cr-N coatings

    CERN Document Server

    Liu, C; Ziegele, H; Leyland, A; Matthews, A

    2002-01-01

    PVD Cr-N coatings produced by physical vapor deposition (PVD) are increasingly used for mechanical and tribological applications in various industrial sectors. These coatings are particularly attractive for their excellent corrosion resistance, which further enhances the lifetime and service quality of coated components. PVD Cr-N coated steels in an aqueous solution are usually corroded by galvanic attack via through-coating 'permeable' defects (e.g., pores). Therefore, the corrosion performance of Cr-N coated steel is determined by a number of variables of the coating properties and corrosive environment. These variables include: (i) surface continuity and uniformity; (ii) through-coating porosity; (iii) film density and chemical stability; (iv) growth stresses; (v) interfacial and intermediate layers; (vi) coating thickness; (vii) coating composition; and (viii) substrate properties. In this article, PVD Cr-N coatings were prepared, by electron-beam PVD and sputter deposition, with different compositions, t...

  11. Minimal watering regime impacts on desert adapted green roof plant performance

    Science.gov (United States)

    Kovachich, S.; Pavao-Zuckerman, M.; Templer, S.; Livingston, M.; Stoltz, R.; Smith, S.

    2011-12-01

    Roof tops can cover one-fifth of urban areas and can greatly alter the movement of matter and energy in cities. With traditional roofing methods and materials, roof tops readily absorb heat and as a result, buildings and the surrounding urban area heat to unnaturally high temperatures. It is hypothesized that extensive green roofs would have wide-ranging benefits for arid environments. However, little is known about the cost of water use associated with green roof installations and how to balance energy reduction needs with water costs in this water limited environment. We are conducting a pilot study to test whether a) green roofs with native plants and environmentally-responsible watering regimes will prove successful in arid environments and if b) green roofs provide ecosystem services with responsible water application. Three species of Sonoran Desert natives, Dyssodia pentachaeta (groundcover), Calliandra eriophylla (shrub), and Hesperaloe parviflora (succulent) have been planted in experimental plots [1 m2 model houses and roofs, replicated in triplicate] with two sandy, rocky desert soil mixtures (light mix: 60% expanded shale and heavy mix: organic and sandy mix with 50% shale) at the Biosphere 2 campus near Oracle, Az. The green roofs are watered by two different techniques. The first technique provides "smart watering", the minimal amount of water needed by green roof plants based on precipitation and historical data. The second watering technique is considered heavy and does not take into account environmental conditions. Preliminary data from the experimental plots shows a 30% decrease in daytime roof top temperatures on green roofs and a 10% decrease in interior temperatures in buildings with green roofs. This trend occurs with both watering regimes (heavy and light). This finding suggests that additional irrigation yields no extra heat reduction and energy savings. In order to explain this phenomenon more clearly, we use co-located temperature and

  12. GREEN ROOFS AS A TOOL FOR IMPROVEMENT THE STORMWATER MANAGEMENT IN URBAN AREAS

    Directory of Open Access Journals (Sweden)

    Ewa Burszta-Adamiak

    2014-10-01

    Full Text Available The interest in green roof technologies is increasing due to the many tangible benefits that allow to provide. One of them is the ability to improve stormwater management in urban areas, because construction of green roofs can retain and delay in runoff . Due to the fact that the market of green roofs in Poland is relatively young, there is still a need for research to provide detailed information about green roof hydrologic performance in the national climate conditions. The objective of this study is to present the research results on retention capacity of green roofs, carried out at the Wroclaw University of Life Sciences. The results show that the possibility of water retention is considerably improved at green roofs when antecedent dry weather period lasts longer than one day and the rainfall depth does not exceed 10 mm / day.

  13. Using Remote Sensing to Quantify Roof Albedo in Seven California Cities

    Science.gov (United States)

    Ban-Weiss, G. A.; Woods, J.; Millstein, D.; Levinson, R.

    2013-12-01

    Cool roofs reflect sunlight and therefore can reduce cooling energy use in buildings. Further, since roofs cover about 20-25% of cities, wide spread deployment of cool roofs could mitigate the urban heat island effect and partially counter urban temperature increases associated with global climate change. Accurately predicting the potential for increasing urban albedo using reflective roofs and its associated energy use and climate benefits requires detailed knowledge of the current stock of roofs at the city scale. Until now this knowledge has been limited due to a lack of availability of albedo data with sufficient spatial coverage, spatial resolution, and spectral information. In this work we use a novel source of multiband aerial imagery to derive the albedos of individual roofs in seven California cities: Los Angeles, Long Beach, San Diego, Bakersfield, Sacramento, San Francisco, and San Jose. The radiometrically calibrated, remotely sensed imagery has high spatial resolution (1 m) and four narrow (less than 0.1 μm wide) band reflectances: blue, green, red, and near-infrared. To derive the albedo of roofs in each city, we first locate roof pixels within GIS building outlines. Next we use laboratory measurements of the solar spectral reflectances of 190 roofing products to empirically relate solar reflectance (albedo) to reflectances in the four narrow bands; the root-mean-square of the residuals for the albedo prediction is 0.016. Albedos computed from remotely sensed reflectances are calibrated to ground measurements of roof albedo in each city. The error (both precision and accuracy) of albedo values is presented for each city. The area-weighted mean roof albedo (× standard deviation) for each city ranges from 0.17 × 0.08 (Los Angeles) to 0.29 × 0.15 (San Diego). In each city most roofs have low albedo in the range of 0.1 to 0.3. Roofs with albedo greater than 0.4 comprise less than 3% of total roofs and 7% of total roof area in each city. The California

  14. Performance Improvement of Roof Transparent Solar Still Coupled With Agriculture Greenhouse

    Directory of Open Access Journals (Sweden)

    Alaa H. Salah

    2017-03-01

    Full Text Available In Egyptian desert, growing plants is difficult due to harsh climate (hot at the daytime and cold at the night, infertile  soil,  low  average  rainfall  and  lack  of  fresh  water  for  irrigation  purposes. A set of simple transparent solar stills are integrated with a new solar driven agriculture greenhouse (GH. The stills are placed at the GH roof to use the extra solar radiation (above that required for plant photosynthesis process for water desalination. In addition to water desalination concept the solar still units even reduce the cooling load during the daytime. A net of aluminum metal coated with black colour is placed on the base of the solar still units to raise the water temperature (enhance desalination process and provide partially shading for the GH. Using aluminum net decreases also the number of solar still units required to produce the required amount of GH  fresh water leading to a significant cost reduction.The main objectives of this work are sizing of the aluminum net, spacing between solar still units to obtain the threshold of plant requirements. Also fresh water production and greenhouse climatic conditions that plant needs (temperature, relative humidity, air velocity and amount of oxygen are simulated.Numerical simulation was carried out for the hottest day of Borg Elarab, Alexandria (Egypt. 

  15. Energy and Economic Evaluation of Green Roofs for Residential Buildings in Hot-Humid Climates

    OpenAIRE

    Abubakar S. Mahmoud; Muhammad Asif; Mohammad A. Hassanain; Mohammad O. Babsail; Muizz O. Sanni-Anibire

    2017-01-01

    Green roofs may be considered a passive energy saving technology that also offer benefits like environmental friendliness and enhancement of aesthetic and architectural qualities of buildings. This paper examines the energy and economic viability of the green roof technology in the hot humid climate of Saudi Arabia by considering a modern four bedroom residential building in the city of Dhahran as a case study. The base case and green roof modelling of the selected building has been developed...

  16. Establishment and performance of an experimental green roof under extreme climatic conditions.

    Science.gov (United States)

    Klein, Petra M; Coffman, Reid

    2015-04-15

    Green roofs alter the surface energy balance and can help in mitigating urban heat islands. However, the cooling of green roofs due to evapotranspiration strongly depends on the climatic conditions, and vegetation type and density. In the Southern Central Plains of the United States, extreme weather events, such as high winds, heat waves and drought conditions pose challenges for successful implementation of green roofs, and likely alter their standard performance. The National Weather Center Experimental Green Roof, an interdisciplinary research site established in 2010 in Norman, OK, aimed to investigate the ecological performance and surface energy balance of green roof systems. Starting in May 2010, 26 months of vegetation studies were conducted and the radiation balance, air temperature, relative humidity, and buoyancy fluxes were monitored at two meteorological stations during April-October 2011. The establishment of a vegetative community trended towards prairie plant dominance. High mortality of succulents and low germination of grasses and herbaceous plants contributed to low vegetative coverage. In this condition succulent diversity declined. Bouteloua gracilis and Delosperma cooperi showed typological dominance in harsh climatic conditions, while Sedum species experienced high mortality. The plant community diversified through volunteers such as Euphorbia maculate and Portulaca maculate. Net radiation measured at a green-roof meteorological station was higher than at a control station over the original, light-colored roofing material. These findings indicate that the albedo of the green roof was lower than the albedo of the original roofing material. The low vegetative coverage during the heat and drought conditions in 2011, which resulted in the dark substrate used in the green roof containers being exposed, likely contributed to the low albedo values. Nevertheless, air temperatures and buoyancy fluxes were often lower over the green roof indicating

  17. Thermal performance of sisal fiber-cement roofing tiles for rural constructions

    OpenAIRE

    Tonoli,Gustavo Henrique Denzin; Santos,Sérgio Francisco dos; Rabi,José Antonio; Santos,Wilson Nunes dos; Savastano Junior,Holmer

    2011-01-01

    Roofing provides the main protection against direct solar radiation in animal housing. Appropriate thermal properties of roofing materials tend to improve the thermal comfort in the inner ambient. Nonasbestos fiber-cement roofing components reinforced with cellulose pulp from sisal (Agave sisalana) were produced by slurry and dewatering techniques, with an optional addition of polypropylene fibers. Nonasbestos tiles were evaluated and compared with commercially available asbestos-cement sheet...

  18. Inventory assessment and determination of properties of dust contamination in the Shelter under-roof space

    International Nuclear Information System (INIS)

    Bogatov, S.A.

    2000-01-01

    Experimental results on study of radionuclide contamination of surfaces under the roof of Shelter have been analyzed. Values of 'loose' and fixed fuel contamination densities and aerodynamic diameters of dust particles capable of resuspension are obtained. Long term efficiency of dust suppression system under the Shelter roof has been estimated. On the base of retrospective analysis of the results, fuel dust inventory on the surfaces under the Shelter roof was evaluated. 14 refs., 5 tab., 3 figs

  19. Field Evaluation of Four Novel Roof Designs for Energy-Efficient Manufactured Homes

    Energy Technology Data Exchange (ETDEWEB)

    Levy, E. [Levy Partnership Inc., New York, NY (United States); Dentz, J. [Levy Partnership Inc., New York, NY (United States); Ansanelli, E. [Levy Partnership Inc., New York, NY (United States); Barker, G. [Levy Partnership Inc., New York, NY (United States); Rath, P. [Levy Partnership Inc., New York, NY (United States); Dadia, D. [Levy Partnership Inc., New York, NY (United States)

    2015-12-01

    A five-bay roof test structure was built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes. The roof structure in Jamestown, California was designed to examine how differences in roof construction impact space conditioning loads, wood moisture content and attic humidity levels. Conclusions are drawn from the data on the relative energy and moisture performance of various configurations of vented and sealed attics.

  20. Measure Guideline. Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-05-29

    This Measure Guideline provides design and construction information for a deep energy enclosure retrofit solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat wood-framed roof with brick masonry exterior walls using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat wood-framed roofs with wood-framed exterior walls.

  1. Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-05-01

    This Measure Guideline provides design and construction information for a deep energy enclosure retrofit (DEER) solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat, wood-framed roof with brick masonry exterior walls, using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat, wood-framed roofs with wood-framed exterior walls.

  2. Monitoring the Energy-Use Effects of Cool Roofs on California Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Levinson, Ronnen; Konopaki, Steve; Rainer, Leo

    2004-07-01

    Solar-reflective roofs stay cooler in the sun than solar-absorptive roofs. Such ''cool'' roofs achieve lower surface temperatures that reduce heat conduction into the building and the building's cooling load. The California Energy Commission has funded research in which Lawrence Berkeley National Laboratory (LBNL) has measured the electricity use and peak demand in commercial buildings to document savings from implementing the Commission's Cool Roofs program. The study seeks to determine the savings achieved by cool roofs by monitoring the energy use of a carefully selected assortment of buildings participating in the Cool Roofs program. Measurements were needed because the peak savings resulting from the application of cool roofs on different types of buildings in the diverse California climate zones have not been well characterized to date. Only a few occupancy categories (e.g., office and retail buildings) have been monitored before this, and those were done under a limited number of climatic conditions. To help rectify this situation, LBNL was tasked to select the buildings to be monitored, measure roof performance before and after replacing a hot roof by a cool roof, and document both energy and peak demand savings resulting from installation of cool roofs. We monitored the effects of cool roofs on energy use and environmental parameters in six California buildings at three different sites: a retail store in Sacramento; an elementary school in San Marcos (near San Diego); and a 4-building cold storage facility in Reedley (near Fresno). The latter included a cold storage building, a conditioning and fruit-palletizing area, a conditioned packing area, and two unconditioned packing areas (counted as one building).

  3. Load test of the 272E Building high bay roof deck and support structure

    International Nuclear Information System (INIS)

    McCoy, R.M.

    1994-01-01

    The 272E Building high bay roof area was load tested according to the approved load-test procedure. The 272E Building is located in the 200 East Area of the Hanford Site and has the following characteristics: Roof deck -- wood decking supported by 4 x 14 timber purlins; Roof membrane -- tar and gravel; Roof slope -- flat (<10 deg); and Roof elevation -- maximum height of about 63 ft. The 272 Building was visited in August 1992 for a visual inspection. During this inspection, cracked areas were visible in the decking, but it was not possible to determine whether these cracks extended completely through the decking, which is 2-in. thick. The building was revisited in March 1994 for the purpose of writing this test report. Because the roof requires personnel access, a test was determine to be the best way to qualify the roof. The pre-test briefing consisted of filling out the pre-test checklist, discussing proper lifting techniques, reviewing the fall-protection plan, reviewing the job hazards analysis, and reviewing the robot travel path. The load-test results consist of visual observations and the test engineer's conclusions. Visual observations found no adverse conditions such as large deflections or permanent deformations. No deflection measurements were recorded because the tar and gravel on roof get displaced by the robot tracks; the result is large variations in deflection measurements. The conclusions are that the roof has been qualified for 500-lb total roof load and that the ''No Roof Access'' signs can be changed to ''Roof Access Restricted'' signs

  4. ANALYSIS OF THE EFFECTS OF THE ROOFING DESIGN ON HEAT STRESS IN DAIRY COW HOUSING

    Directory of Open Access Journals (Sweden)

    Paolo Liberati

    2008-12-01

    Full Text Available A simulation model determining the heat flow exchange between housed animals and the roofing was developed considering various relevant factors: constructive materials, slope, height, orientation, latitude, external air temperature, solar load, animal position. Results show that the most important factor to reduce heat load is the insulation. For non-insulated roofing the slope and the orientation are the most relevant factors. Considering the total exchanged energy, the non insulated roof has a good nocturnal global behaviour.

  5. ANALYSIS OF THE EFFECTS OF THE ROOFING DESIGN ON HEAT STRESS IN DAIRY COW HOUSING

    OpenAIRE

    Paolo Liberati

    2008-01-01

    A simulation model determining the heat flow exchange between housed animals and the roofing was developed considering various relevant factors: constructive materials, slope, height, orientation, latitude, external air temperature, solar load, animal position. Results show that the most important factor to reduce heat load is the insulation. For non-insulated roofing the slope and the orientation are the most relevant factors. Considering the total exchanged energy, the non insulated roof ha...

  6. Frost damage of roof tiles: A study on moisture boundary conditions

    OpenAIRE

    Iba, Chiemi; Ueda, Ayumi; Hokoi, Shuichi

    2015-01-01

    Freeze-thaw cycles are the most serious cause of roof tile deterioration; thus, it is important to know the temperature and moisture distributions in tile materials for protection against frost damage. This study focused on moisture boundary conditions for air layers under the tile. Temperature and humidity were measured using model structures with different types of roof tiles. The results showed that the temperatures around the roof were strongly influenced by solar and longwave radiation, ...

  7. Hyperspectral Monitoring of Green Roof Vegetation Health State in Sub-Mediterranean Climate: Preliminary Results.

    Science.gov (United States)

    Piro, Patrizia; Porti, Michele; Veltri, Simone; Lupo, Emanuela; Moroni, Monica

    2017-03-23

    In urban and industrial environments, the constant increase of impermeable surfaces has produced drastic changes in the natural hydrological cycle. Decreasing green areas not only produce negative effects from a hydrological-hydraulic perspective, but also from an energy point of view, modifying the urban microclimate and generating, as shown in the literature, heat islands in our cities. In this context, green infrastructures may represent an environmental compensation action that can be used to re-equilibrate the hydrological and energy balance and reduce the impact of pollutant load on receiving water bodies. To ensure that a green infrastructure will work properly, vegetated areas have to be continuously monitored to verify their health state. This paper presents a ground spectroscopy monitoring survey of a green roof installed at the University of Calabria fulfilled via the acquisition and analysis of hyperspectral data. This study is part of a larger research project financed by European Structural funds aimed at understanding the influence of green roofs on rainwater management and energy consumption for air conditioning in the Mediterranean area. Reflectance values were acquired with a field-portable spectroradiometer that operates in the range of wavelengths 350-2500 nm. The survey was carried out during the time period November 2014-June 2015 and data were acquired weekly. Climatic, thermo-physical, hydrological and hydraulic quantities were acquired as well and related to spectral data. Broadband and narrowband spectral indices, related to chlorophyll content and to chlorophyll-carotenoid ratio, were computed. The two narrowband indices NDVI 705 and SIPI turned out to be the most representative indices to detect the plant health status.

  8. Hard coatings

    International Nuclear Information System (INIS)

    Dan, J.P.; Boving, H.J.; Hintermann, H.E.

    1993-01-01

    Hard, wear resistant and low friction coatings are presently produced on a world-wide basis, by different processes such as electrochemical or electroless methods, spray technologies, thermochemical, CVD and PVD. Some of the most advanced processes, especially those dedicated to thin film depositions, basically belong to CVD or PVD technologies, and will be looked at in more detail. The hard coatings mainly consist of oxides, nitrides, carbides, borides or carbon. Over the years, many processes have been developed which are variations and/or combinations of the basic CVD and PVD methods. The main difference between these two families of deposition techniques is that the CVD is an elevated temperature process (≥ 700 C), while the PVD on the contrary, is rather a low temperature process (≤ 500 C); this of course influences the choice of substrates and properties of the coating/substrate systems. Fundamental aspects of the vapor phase deposition techniques and some of their influences on coating properties will be discussed, as well as the very important interactions between deposit and substrate: diffusions, internal stress, etc. Advantages and limitations of CVD and PVD respectively will briefly be reviewed and examples of applications of the layers will be given. Parallel to the development and permanent updating of surface modification technologies, an effort was made to create novel characterisation methods. A close look will be given to the coating adherence control by means of the scratch test, at the coating hardness measurement by means of nanoindentation, at the coating wear resistance by means of a pin-on-disc tribometer, and at the surface quality evaluation by Atomic Force Microscopy (AFM). Finally, main important trends will be highlighted. (orig.)

  9. Electrostatic coating technologies for food processing.

    Science.gov (United States)

    Barringer, Sheryl A; Sumonsiri, Nutsuda

    2015-01-01

    The application of electrostatics in both powder and liquid coating can improve the quality of food, such as its appearance, aroma, taste, and shelf life. Coatings can be found most commonly in the snack food industry, as well as in confectionery, bakery, meat and cheese processing. In electrostatic powder coating, the most important factors influencing coating quality are powder particle size, density, flowability, charge, and resistivity, as well as the surface properties and characteristics of the target. The most important factors during electrostatic liquid coating, also known as electrohydrodynamic coating, include applied voltage and electrical resistivity and viscosity of the liquid. A good understanding of these factors is needed for the design of optimal coating systems for food processing.

  10. Commercial/industrial photovoltaic module and array requirement study. Low-cost solar array project engineering area

    Science.gov (United States)

    1981-01-01

    Design requirements for photovoltaic modules and arrays used in commercial and industrial applications were identified. Building codes and referenced standards were reviewed for their applicability to commercial and industrial photovoltaic array installation. Four general installation types were identified - integral (replaces roofing), direct (mounted on top of roofing), stand-off (mounted away from roofing), and rack (for flat or low slope roofs, or ground mounted). Each of the generic mounting types can be used in vertical wall mounting systems. This implies eight mounting types exist in the commercial/industrial sector. Installation costs were developed for these mounting types as a function of panel/module size. Cost drivers were identified. Studies were performed to identify optimum module shapes and sizes and operating voltage cost drivers. The general conclusion is that there are no perceived major obstacles to the use of photovoltaic modules in commercial/industrial arrays.

  11. Single-sided natural ventilation through a centre-pivot roof window

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Nielsen, Peter V.; Gunner, Amalie

    2014-01-01

    The characteristics of centre pivot roof windows for wind driven single-sided ventilation has not been studied before. These types of windows are dominating roof windows in Europe. Knowledge of flow characteristics of this kind of window is essential for accurate designing of natural ventilation...... systems. In this study, numerical methods were used to characterise a centre-pivot roof window for wind-driven single-sided ventilation. A 1:20 scale model house of the Energy Flex House (Denmark) was used in this study. The roof slope was 36o. It was found that the single-sided ventilation through...

  12. Development of a green roof environmental monitoring and meteorological network in new york city.

    Science.gov (United States)

    Gaffin, Stuart R; Khanbilvardi, Reza; Rosenzweig, Cynthia

    2009-01-01

    Green roofs (with plant cover) are gaining attention in the United States as a versatile new environmental mitigation technology. Interest in data on the environmental performance of these systems is growing, particularly with respect to urban heat island mitigation and stormwater runoff control. We are deploying research stations on a diverse array of green roofs within the New York City area, affording a new opportunity to monitor urban environmental conditions at small scales. We show some green roof systems being monitored, describe the sensor selection employed to study energy balance, and show samples of selected data. These roofs should be superior to other urban rooftops as sites for meteorological stations.

  13. Development of a Green Roof Environmental Monitoring and Meteorological Network in New York City

    Directory of Open Access Journals (Sweden)

    Cynthia Rosenzweig

    2009-04-01

    Full Text Available Green roofs (with plant cover are gaining attention in the United States as a versatile new environmental mitigation technology. Interest in data on the environmental performance of these systems is growing, particularly with respect to urban heat island mitigation and stormwater runoff control. We are deploying research stations on a diverse array of green roofs within the New York City area, affording a new opportunity to monitor urban environmental conditions at small scales. We show some green roof systems being monitored, describe the sensor selection employed to study energy balance, and show samples of selected data. These roofs should be superior to other urban rooftops as sites for meteorological stations.

  14. The Green Roof Microbiome: Improving Plant Survival for Ecosystem Service Delivery

    Directory of Open Access Journals (Sweden)

    Roberta Fulthorpe

    2018-02-01

    Full Text Available Plants are key contributors to ecosystem services delivered by green roofs in cities including stormwater capture, temperature regulation, and wildlife habitat. As a result, current research has primarily focused on their growth in relationship to extensive green roof (e.g., substrates <15 cm depth ecosystem services. Green roofs are exposed to a variety of harsh abiotic factors such as intense solar radiation, wind, and isolation from ground-level habitats, making survival exceedingly difficult. Plants in natural habitats benefit from a variety of interactions with fungi and bacteria. These plant-microbial interactions improve mechanisms of survival and productivity; however, many green roof substrates are sterilized prior to installation and lack microbial communities with unstudied consequences for green roof plant health and subsequent survival and performance. In this paper, we present six hypotheses on the positive role of microbes in green roof applications. In natural and experimental systems, microbial interactions have been linked to plant (1 drought tolerance, (2 pathogen protection, (3 nutrient availability, (4 salt tolerance, (5 phytohormone production, and (6 substrate stabilization, all of which are desirable properties of green roof ecosystems. As few studies exist that directly examine these relationships on green roofs, we explore the existing ecological literature on these topics to unravel the mechanisms that could support more complex green roof ecosystem and lead to new insight into the design, performance, and broader applications in green infrastructure.

  15. Effect of highly reflective roofing sheet on building thermal loads for a school in Osaka

    Directory of Open Access Journals (Sweden)

    Yuan Jihui

    2017-01-01

    Full Text Available Currently, urban heat island (UHI phenomenon and building energy consumptions are becoming serious. Strategies to mitigate UHI and reduce building energy consumptions are implemented worldwide. In Japan, as an effective means of mitigating UHI and saving energy of buildings, highly reflective (HR and green roofs are increasingly used. In order to evaluate the effect of roofs with high reflection and thermal insulation on the energy conservation of buildings, we investigated the roof solar reflectivity of the subject school in Osaka, in which the HR roofing sheet was installed on the roof from 2010. Thermal loads, including cooling and heating loads of the top floor of school, were calculated using the thermal load calculation software, New HASP/ACLD-β. Comparing the thermal loads after HR roofing sheet installation to previous, the annual thermal load decreased about 25 MJ/m2-year and the cooling load decreased about 112 MJ/m2-year. However, the heating load increased about 87 MJ/m2-year in winter. To minimize the annual thermal load, thermal insulation of the roof was also considered be used together with HR roofing sheet in this study. The results showed that the combination of HR roofing sheet and high thermal insulation is more effective to reduce the annual thermal load.

  16. Eco-Environmental Factors in Green Roof Application in Indian Cities

    Science.gov (United States)

    Mukherjee, M.

    2014-09-01

    Green-roof is the cost-effective environmental mitigation strategy for urban areas [1]. Its application is limited in India primarily due to inadequate understanding about its cost-benefit analysis and technicalities of its maintenance. Increasing awareness about green roof can alter conservative attitude towards its application. So, this work presents a quantified study on green-roof types, cost and environmental benefits while considering different geo-urban climate scenarios for cities of Kolkata, Mumbai, Chennai and New Delhi. Cost estimation for extensive and intensive green-roof with reference to commonly used roof in urban India is also worked out. Attributes considered for environmental discussion are energy savings related to thermal heat gain through roof, roof-top storm-water drainage and sound attenuation. The comparative study confirms that further focused study on individual cities would identify city-specific objectives for green-roof application; strategies like awareness, capacity building programmes, incentives, demonstration projects etc. can be worked out accordingly for wider application of green-roof in Indian cities.

  17. Experimental evaluation of thermal and energy performance of temperate green roofs: a case study in Beijing

    Science.gov (United States)

    Sun, T.; Institute of Hydrology; Water Resources

    2011-12-01

    An experimental evaluation of thermal and energy performance of temperate green roofs was carried out by thermal and meteorological observation and energy budget modeling using a setup of green roof in Beijing urban area. From both the yearly and daily temperature trends, the green roof could effectively damp down the undulation of roof surface temperature comparing with the conventional one. As an insulating screen, the green roof abated the amplitude of temperature by 9.0 in winter and 9.1 °C in summer, respectively. Under different cloud conditions, the green roof in summer time resulted in decreases in sensible heat and heat flux by 125.3W m-2 and 32.0 W m-2, respectively, on daily average comparing with the conventional one. Based on the energy budget analyses, under an assumptive scenario of 50% roof-greening in Beijing, a total of 34.1 PJ of sensible heat and 8.7 PJ of heat flux would be decreased for a summer period of 90 days. This study demonstrated that green roof, serving as an insulating screen to building top in comparison with the conventional roof, proved thermal improving effect in building scale and high energy saving potential for urban development.

  18. Graphene-coated polystyrene-divinylbenzene dispersive solid-phase extraction coupled with supercritical fluid chromatography for the rapid determination of 10 allergenic disperse dyes in industrial wastewater samples.

    Science.gov (United States)

    Lou, Chaoyan; Wu, Can; Zhang, Kai; Guo, Dandan; Jiang, Lei; Lu, Yang; Zhu, Yan

    2018-05-18

    Allergenic disperse dyes are a group of environmental contaminants, which are toxic and mutagenic to human beings. In this work, a method of dispersive solid-phase extraction (d-SPE) using graphene-coated polystyrene-divinylbenzene (G@PS-DVB) microspheres coupled with supercritical fluid chromatography (SFC) was proposed for the rapid determination of 10 allergenic disperse dyes in industrial wastewater samples. G@PS-DVB microspheres were synthesized by coating graphene (G) sheets onto polystyrene-divinylbenzene (PS-DVB) polymers. Such novel sorbents were employed in d-SPE for the purification and concentration of allergenic disperse dyes in wastewater samples prior to the determination by SFC with UV detection. To achieve the maximum extraction efficiency for the target dyes, several parameters influencing d-SPE process such as sorbent dosage, extraction time, desorption conditions were investigated. SFC conditions including stationary phase, modifier composition and percentage, column temperature, backpressure and flow rate were optimized to well separate the allergenic disperse dyes. Under the optimum conditions, satisfactory linear relationship (R ≥ 0.9989) was observed with the concentration of dyes ranging from 0.02 to 10.0 μg/mL. The limits of detection (LOD, S/N = 3) for the ten dyes were in the range of 1.1-15.6 ng/mL. Recoveries for the spiked samples were between 89.1% and 99.7% with relative standard deviations (RSD) lower than 10.5% in all cases. The proposed method is time-saving, green, precise and repeatable for the analysis of the target dyes. Furthermore, the application of G@PS-DVB based d-SPE process can be potentially expanded to isolate and concentrate other aromatic compounds in various matrices and supercritical fluid chromatography methodology featuring rapidity, accuracy and green will be an ideal candidate for the analysis of these compounds. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Asphalt Roofing Shingles Into Energy Project Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Jameson, Rex, PE

    2008-04-28

    Based on a widely cited September, 1999 report by the Vermont Agency of Natural Resources, nearly 11 million tons of asphalt roofing shingle wastes are produced in the United States each year. Recent data suggests that the total is made up of about 9.4 million tons from roofing tear-offs and about 1.6 million tons from manufacturing scrap. Developing beneficial uses for these materials would conserve natural resources, promote protection of the environment and strengthen the economy. This project explored the feasibility of using chipped asphalt shingle materials in cement manufacturing kilns and circulating fluidized bed (CFB) boilers. A method of enhancing the value of chipped shingle materials for use as fuel by removing certain fractions for use as substitute raw materials for the manufacture of new shingles was also explored. Procedures were developed to prevent asbestos containing materials from being processed at the chipping facilities, and the frequency of the occurrence of asbestos in residential roofing tear-off materials was evaluated. The economic feasibility of each potential use was evaluated based on experience gained during the project and on a review of the well established use of shingle materials in hot mix asphalt. This project demonstrated that chipped asphalt shingle materials can be suitable for use as fuel in circulating fluidized boilers and cement kilns. More experience would be necessary to determine the full benefits that could be derived and to discover long term effects, but no technical barriers to full scale commercial use of chipped asphalt shingle materials in these applications were discovered. While the technical feasibility of various options was demonstrated, only the use of asphalt shingle materials in hot mix asphalt applications is currently viable economically.

  20. Roof top extensions for multifamily houses in Slovakia

    Science.gov (United States)

    Szekeres, K.

    2010-12-01

    In the countries of the European Union with the exception of Malta, approximately 100.1 million multifamily dwelling units are situated. These dwellings count for an average of 47.5% of the total housing stock in European Union countries. At present in Slovakia and also other countries of Central and Eastern Europe, there are vast housing areas which were built after World War II. Slovakia's multifamily housing stock was privatized during the 1990s. Considering that the economy of Slovakia is not capable of replacing the existing housing fund, which is located in the multifamily houses that were built after World War II, it is necessary to place an increased emphasis on the renovation of this housing fund. The expenditures for the refurbishment of multifamily housing stock in recent decades, when compared with the demand, have been at a very low level. The main problems involving the current multifamily housing stock in Slovakia are: the need for modernization, the low level of energy efficiency, and the insufficient level of building maintenance. One of the options for creating sufficient sources for the renovation of apartment buildings is to utilize the roofs of apartment buildings as construction areas for building additional floors (over - roofing). The means acquired from the sale of the new floors after deducting the costs can be used for renovation. It is a matter of a one-time possibility, which is limited by many factors that depend on the localization and constructive technical solutions for apartment buildings. This article is an outcome of the SuReFit "Sustainable Roof Extension Retrofit for High-Rise Social Housing in Europe" international research project.