  1. Industrial radiography

    International Nuclear Information System (INIS)

    1992-01-01

    Industrial radiography is a non-destructive testing (NDT) method which allows components to be examined for flaws without interfering with their usefulness. It is one of a number of inspection methods which are commonly used in industry to control the quality of manufactured products and to monitor their performance in service. Because of its involvement in organizing training courses in all the common NDT methods in regional projects in Asia and the Pacific and Latin America and the Caribbean and in many country programmes, the Agency is aware of the importance of standardizing as far as possible the syllabi and training course notes used by the many experts who are involved in presenting the training courses. IAEA-TECDOC-628 ''Training Guidelines in Non-destructive Testing'' presents syllabi which were developed by an Agency executed UNDP project in Latin America and the Caribbean taking into account the developmental work done by the International Committee for Non-destructive Testing. Experience gained from using the radiography syllabi from TECDOC-628 at national and regional radiography training courses in the Agency executed UNDP project in Asia and the Pacific (RAS/86/073) showed that some guidance needed to be given to radiography experts engaged in teaching at these courses on the material which should be covered. The IAEA/UNDP Asia and Pacific Project National NDT Coordinators therefore undertook to prepare Radiography Training Course Notes which could be used by experts to prepare lectures for Level 1,2 and 3 radiography personnel. The notes have been expanded to cover most topics in a more complete manner than that possible at a Level 1, 2 or 3 training course and can now be used as source material for NDT personnel interested in expanding their knowledge of radiography. Refs, figs and tabs

  2. Industrial radiographies

    CERN Multimedia

    2005-01-01

    The Radiation Protection group wishes to remind CERN staff responsible for contractors performing X-ray inspections on the CERN sites that the firms must apply the legislation in force in their country of origin, in particular with regard to the prevention of risks relating to ionizing radiation. Industrial radiography firms called on to work on the CERN sites must also comply with the rules laid down in CERN's Radiation Safety Manual and be registered in the relevant CERN database. Since CERN is responsible for safety on its own site, a number of additional rules have been laid down for this kind of work, as set out in Radiation Protection Procedure PRP30 https://edms.cern.ch/file/346848/LAST_RELEASED/PRP30.pdf The CERN Staff Member responsible for the contract shall register the company and issue notification that an X-ray inspection is to be performed via the web interface at the following address: http://cern.ch/rp-radio

  3. Manual on industrial radiography

    International Nuclear Information System (INIS)

    1981-08-01

    This manual is intended as a source of educational material to personnel seeking certification as industrial radiographers, and as a guide and reference text for educational organizations that are providng courses in industrial radiography. It covers the basic principles of x-ray and gamma radiation, radiation safety, films and film processing, welding, casting and forging, aircraft structures and components, radiographic techniques, and records

  4. Saferad industrial radiography system

    International Nuclear Information System (INIS)

    Lima, Wallace Aparecido de

    2005-01-01

    The Saferad industrial radiography system is a system for execution of radiographic tests that provide small rays of insulation compared to conventional techniques. The system consists of a special irradiator that can be operated in three modes of exposure: Projection, Directional, and Panoramic with a set of collimators for different diameters of tubes, which collimate the radiation only to the area of the film. The radioisotope used is Selenium-75. Complements the system the shielding GammaBlok, polymer based on cadmium, flexible, non-toxic, and presented in various dimensions and shapes. It should involve the radiographic arrangement to shield the radiation after it goes through the film and the scattered radiation

  5. Educational aspects of industrial radiography

    International Nuclear Information System (INIS)

    Krishnamurthy, K.; Wamorkar, R.R.; Singh, G.

    1979-01-01

    The state of art of training and education in non-destructive testing in India, with special reference to industrial radiography is reviewed. Basic requirement of industry and potential of radioisotopes in industrial inspection are also described. Need for an organised training programme in industrial isotope radiography to exploit potentials for benefit of industry concurrent with the safety is stressed. A comprehensive training programme tailored to meet the needs of Indian industry is outlined. Benefits obtained from the course to the industry since the beginning of the training programme are briefly reviewed. (auth.)

  6. Site radiography in boiler industry

    International Nuclear Information System (INIS)

    Hemachandran, P.

    1977-01-01

    Isotope radiography enjoys a unique position in radiography of weldments made at erection sites of industrial boilers. It also faces problems due to unfavourable conditions existing in these sites. The over-all approach to radiography at boiler erection sites has been dealt with. The advantages of modern X-ray and gamma ray equipment for these particular applications are discussed. A few useful accessories which reduce the complexity of source positioning and allied problems due to elevated position are suggested. Safety problems at sites are also dealt with. (author)

  7. Radiation safety for industrial radiography

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    For many years, x-rays and gamma radiography have successfully been used in the field of non-destructive testing (NDT). Their capability of penetrating heavy materials has made them very useful in detection of discontinuities or defects in engineering systems or components. Since the first radiograph was shot in 1895 by Roentgen, a large number of people have become involved with radiography the world over. All forms of ionizing radiation are extremely harmful to living tissues. This means that the properties of ionizing radiation, which make radiography such a valuable industrial tool, also make it potentially injurious to human body. It is for this reason radiography should not be performed by unqualified personnel or with improper equipment or facilities. This book presents information necessary for protection against radiation hazard. It will hopefully assist radiographers in gaining knowledge regarding various aspects of radiation, its effect to human lives and procedures to be followed to minimize the risk of over-exposure. (Authors)

  8. Introduction to industrial radiography

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    For the first topic in this book, more on introduction to nondestructive testing, also a little bit on another technique such as magnetic testing, liquid penetrated, ultrasonic testing and others. This book mentions more on radiographic testing and for that, more details on this topic such as history, definition and devices that use in this technique. This radiography testing firstly started with the discovering of x-ray by Wilhelm Roentgen (1895). So, on 1913, David Coolidge successfully invented and developed x-ray tube that could made x-ray more intensified and produced highly penetration forces. Radiography in Malaysia firstly started two years after the discovery made by Wilhelm Roentgen when one hospital here used the x-ray machine for medical purposes. Besides using x-ray, radiography also used gamma rays, and for these purpose, they used Co-60 and Ir-192. Now, more company based on NDT established to provide a service on inspection pipe and others. For filled these requirement, radiographer must take an exam to make them expert and trained well to work in this field. There is no advantage using this technique or other technique. So that's why this book was published to make people understand what is radiographic testing truly.

  9. Industrial Radiography | Radiation Protection | US EPA

    Science.gov (United States)

    2017-08-07

    Manufacturers use a method called industrial radiography to check for cracks or flaws in materials. Radiation is used in industrial radiography to show problems not visible from the outside without damaging the material.

  10. Radiological security for industrial radiography

    International Nuclear Information System (INIS)

    Montoya G, Manuel.

    1985-04-01

    This report comprises the basic notions of nucleonics, simple calculations for point sources, X-rays, calculations for coatings, standards for radiation protection and industrial radiography instruments. The preceding sums up with the biological effects of ionizing radiation. This is a guide for people who wish to pass examinations, to get the license for radiological safety, for operators on gamma-graphic sources, which work in the country. It is a requirement for work with this kind of radioactive sources

  11. Industrial Radiography Manual.

    Science.gov (United States)

    Richardson, Harry D.

    This text was developed for use by students in an 80-hour course for industrial radiographers. Chapter headings are: (1) The Structure of Matter, (2) Radiation and Radiation Machines, (3) Nuclear Reactions and Radioisotopes, (4) Interaction of Radiation with Matter, (5) Radiation Detection and Measurement, (6) The Nature and Consequences of…

  12. Industrial Radiography Instructor's Guide.

    Science.gov (United States)

    Richardson, Harry D.

    The curriculum guide was developed for teacher use in an 80-hour course for industrial radiographers. The units include: (1) The Structure of Matter and Radiation, (2) Nuclear Reactions and Radioisotopes, (3) The Nature and Consequences of Radiation Exposure, (4) Radiation Attenuation, (5) Absorption of Radiation, (6) Radiation Detection and…

  13. Industrial radiography X and Gamma

    International Nuclear Information System (INIS)

    Torres M, Nelson; Torres B, Miguel; Montanez, Juan.

    1986-04-01

    This publication gives a practical orientation on industrial radiography. The first chapters deal with basic facts that are useful for professional work in this field. It comprises topics such as generation of X-rays, equipment being used, radiographic films, sensibility, and the penetrameters used. This publication also describes the most used radiographic techniques and the processing of the radiographic film. It contains practical recommendations on how to obtain a good radiographic inspection. It states the reasons for defects in the radiographies. Two annexes are attached which include tables for the selection of penetrameters according to the ASME and DIN codes as well as the time needed for development and fixing according to the temperature

  14. Radioprotection of industrial radiography

    International Nuclear Information System (INIS)

    Abela, G.; Bonaventure, P.; Jupin, L.; Truchi, F.

    2006-01-01

    The EDF Nuclear Power Division (N.P.D.) conducts a substantial number of industrial g-ray inspections: about 40.000 inspections are conducted annually on the nuclear fleet by contractors as H.O.R.U.S. Company. Point sources of Iridium 192 are generally used. In normal configurations, the activity of these sources can go up to 4.4 T.Bq (120 Ci), inducing - at a range of 1 meter - such a high dose equivalent rate that the value of 20 mSv is reached in a little more than 2 minutes. To date, no exceeding of the regulatory limit has been observed within EDF, but during the observation of events, a practice that has been in effect for many years, 'low-level events', such as unplanned exposures lower than the regulatory limits, were noted. N.P.D. management and contractors thus decided to take particular actions in the field. An analysis of unplanned exposures was carried out. This analysis related to 1: The 'human factor' analysis showed that the activity, which can seem 'simple' due to its seemingly basic constituent parts, taken in isolation, therefore appears easy to accomplish. In fact, completion of each point requires very extensive technical training, a complex planning file has to be compiled as there are many interfaces with other players, is linked to other activities that have to be carried out prior to the g-ray inspection. It requires preparation of the areas, with measures taken to prohibit access, and requires adaptation to physical conditions (temperature, lighting, noise, dose rate) and sometimes very difficult access conditions. The operators 'error' and lack of attention or vigilance cannot thus be considered by a preventer as being a satisfactory cause of incidents or accidents, within the scope of an ongoing improvement initiative: Vigilance means work. 2: Analysis of material causes did not highlight causes related to the equipment used, but camera ergonomics could be improved. Changes to EDF rules focused on: Compulsory and systematic use of

  15. Radiological safety aspects of industrial radiography

    International Nuclear Information System (INIS)

    Hanekom, A.P.

    1983-01-01

    Industrial radiography and especially gamma-radiography, has established itself as a very powerful tool in non-destructive testing. Unfortunately there is an amount of risk attached to the use of industrial radiography. The primary causes of radiography accidents include: working conditions, equipment failure and lack of supervisory control. To alleviate the radiological risks involved with gamma-radiography, the Atomic Energy Corporation (AEC) has imposed various conditions for the possession, use, and conveyance of radioactive material. This includes personnel training and equipment specifications

  16. INDUSTRIAL RADIOGRAPHY STUDENT GUIDE AND LABORATORY EXERCISES.

    Science.gov (United States)

    Bureau of Adult, Vocational, and Technical Education (DHEW/OE), Washington, DC. Div. of Vocational and Technical Education.

    THIS INSTRUCTOR'S GUIDE TO AN 80-HOUR COURSE IN INDUSTRIAL RADIOGRAPHY IS COORDINATED WITH LESSONS IN THE STUDENT GUIDE AND LABORATORY EXERCISES AND IS BASED ON MATERIAL IN THE COURSE MANUAL, INDUSTRIAL RADIOGRAPHY. THE COURSE IS INTENDED TO TRAIN HIGH SCHOOL GRADUATES AS BEGINNING RADIOGRAPHERS WHO ARE EXPECTED TO BE ABLE TO EXTEND THEIR…

  17. Charter of good practices in industrial radiography

    International Nuclear Information System (INIS)

    2010-01-01

    This document describes good practices in the field of industrial radiography. After having presented the main prevention and radiation protection principles, the actors inside and outside of the company, and actors intervening during an operation subcontracting in industrial radiography, this report analyzes the activity: prerequisites for work preparation, prevention coordination, work preparation, transportation, work achievement, return on experience. It addresses personnel training and information, and the dosimetric and medical monitoring of technicians in industrial radiography. Some aspects are addressed in appendix: principles (justification, optimization, and limitation), regulations, intervention form, exposure form, and so on

  18. Image analysis in industrial radiography

    International Nuclear Information System (INIS)

    Lavayssiere, B.

    1993-01-01

    Non-destructive testing in nuclear power plants remains a major EDF objective for the coming decades. To facilitate diagnosis, the expert must be provided with elaborate decision-making aids: contrasted images, noise-free signals, pertinent parameters, ''meaningful'' images. In the field of industrial radiography, the inspector's offer of a portable system for digitalization and subsequent processing of radiographs (ENTRAIGUES) is an improvement in the inspection of primary circuit nozzles. Three major directions were followed: - improvement of images and localization of flaws (2D approach); techniques such as Markov modelling were evaluated and tested, - development of a system which can be transported on site, for digitalization, processing and subsequent archiving on inspection radiographs, known as ENTRAIGUES, - development of a program for aid in analysis of digitized radiographs (''bread-board'' version), offering an ergonomic interface and push-button processing, which is the software component in ENTRAIGUES and uses sophisticated methods: contrast enhancement, background flattening, segmentation. An other objective is to reconstruct a three-dimensional volume on the basis of a few radiographs taken at different incidences and to estimate the flaw orientation within a piece understudy. This information makes sense to experts, with regards to the deterioration rate of the flaw; the equipment concerned includes the formed bends in the primary coolant nozzles. This reconstruction problem is ill-posed and a solution can be obtained by introducing a priori information on the solution. The first step of our algorithm is a classical iterative reconstruction A.R.T. type method (Algebraic Reconstruction Techniques) which provides a rough volumic reconstructed tridimensional zone containing the flaw. Then, on this reconstructed zone, we apply a Bayesian restoration method introducing a Markov Random Field (MRF) modelling. Conclusive results have been obtained. (author

  19. Standing of industrial radiography in South Africa

    International Nuclear Information System (INIS)

    Marais, J.J.

    1983-01-01

    In this article a look is taken at industrial radiography in South Africa to determine where radiographic testing is being used, and for what reasons. The status of training of industrial radiographers is considered and it is compared to radiographic techniques used in South Africa

  20. Industrial radiography in the Philippines: safety concerns

    International Nuclear Information System (INIS)

    David, Jocelyn L.; Artificio, Thelma P.; Cerbolles, Justina S.; Caseria, Estrella S.; Agron, Inocencio A.

    2005-01-01

    Industrial radiography utilizes the highest activity (5.55 tera becquerel (TBq) to 7.4 TBq) among the various mobile application of radioisotopes. It is highly possible that radiographers exceed the annual dose limits for workers occupationally exposed to radiation (as prescribed in the Code of PNRI Regulations part 3) if they do not give cautious consideration to the factors that determine the radiation dose, namely: the gamma source dose rates, time distance and shielding. To enhance the safety culture among radiographers, various strategies are recommended to be undertaken by the Philippine Nuclear Research Institute as well as the licensed companies undertaking activities in industrial radiography. (Authors)

  1. Code of practice in industrial radiography

    International Nuclear Information System (INIS)

    Karma, S. E. M.

    2010-12-01

    The aim of this research is to developing a draft for a new radiation protection code of practice in industrial radiography without ignoring that one issued in 1998 and meet the current international recommendation. Another aim of this study was to assess the current situation of radiation protection in some of the industrial radiography department in Sudan. To achieve the aims of this study, a draft of a code of practice has been developed which is based on international and local relevant recommendations. The developed code includes the following main issues: regulatory responsibilities, radiation protection program and design of radiation installation. The practical part of this study includes scientific visits to two of industrial radiography departments in Sudan so as to assess the degree of compliance of that department with what state in the developed code. The result of each scientific visits revealed that most of the department do not have an effective radiation protection program and that could lead to exposure workers and public to unnecessary dose. Some recommendations were stated that, if implemented could improve the status of radiation protection in industrial radiography department. (Author)

  2. Conditions for radiation protection in industrial radiography

    CERN Document Server

    1999-01-01

    The leaflet specifies radiation protection requirements for industrial radiography in Norway. The regulations are directed towards companies using or distributing sealed radioactive sources, x-ray equipment or accelerators in non-destructive material testing (NDT). Technical requirements to the equipment, as well as administrative requirements for use, licensing, qualifications, handling of accidents etc. are given. (Author)

  3. INDUSTRIAL RADIOGRAPHY COURSE, INSTRUCTORS' GUIDE. VOLUME 2.

    Science.gov (United States)

    Texas A and M Univ., College Station. Engineering Extension Service.

    INFORMATION RELATIVE TO THE LESSON PLANS IN "INDUSTRIAL RADIOGRAPHY COURSE, INSTRUCTOR'S GUIDE, VOLUME I" (VT 003 565) IS PRESENTED ON 52 INFORMATION SHEETS INCLUDING THE SUBJECTS SHIELDING EQUATIONS AND LOGARITHMS, METAL PROPERTIES, FIELD TRIP INSTRUCTIONS FOR STUDENTS, WELDING SYMBOLS AND SIZES, SAMPLE REPORT FORMS, AND TYPICAL SHIPPING…

  4. Regulations for radiation protection in industrial radiography

    International Nuclear Information System (INIS)

    1974-01-01

    These Regulations specify that responsibility for applying radiation protection regulations in industrial radiography rests with the owner of the establishment who will designate a radiation protection officer to this effect. They provide for the organisation of radiation protection, including the measures to be observed, exposure limits, etc. The competent authority for these questions is the State Institute of Radiation Hygiene [fr

  5. 10 CFR 34.13 - Specific license for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Specific license for industrial radiography. 34.13 Section 34.13 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY... safety responsibilities in industrial radiography, including specified delegation of authority and...

  6. Safety Testing of Industrial Radiography Devices

    International Nuclear Information System (INIS)

    Trapp, D.J.

    1999-01-01

    The Nuclear Regulatory Commission contracted the Savannah River Technology Center to verify the relevancy of the 10 CFR Part 34 requirements for the normal use of portable gamma radiography systems and to propose recommendations for changes or modifications to the requirements

  7. Industrial radiography on radiographic paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-11-01

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings, assemblies, etc. (author)

  8. Multidimensional analysis in industrial radiography

    International Nuclear Information System (INIS)

    Lavayssiere, B.; Georgel, B.

    1992-01-01

    EDF uses non-destructive testing by X or gamma-ray radiography for routine nozzle inspection in nuclear power plants. The images obtained are examined by radiographic specialists in order to detect, identify and quantify any defects, but the quality of the radiograms and the small size of the defects make their work extremely difficult. It is for these reasons that EDF developed ENTRAIGUES, a digital package for the processing and aid in interpretation of images generated by radiographical inspections, aimed at: -digitizing the radiographic films to be appraised, - facilitating analysis of the digitized radiograms. Defect orientation is estimated by 3D reconstruction of the component being inspected, based on a limited number of its projections. (authors). 11 figs., 6 refs

  9. Applications of neutron radiography for the nuclear power industry

    Energy Technology Data Exchange (ETDEWEB)

    Craft, Aaron E.; Barton, John P.

    2016-11-01

    The World Conference on Neutron Radiography (WCNR) and International Topical Meeting on Neutron Radiography (ITMNR) series have been running over 35 years. The most recent event, ITMNR-8, focused on industrial applications and was the first time this series was hosted in China. In China, more than twenty new nuclear power plants are in construction and plans have been announced to increase the nuclear capacity further by a factor of three within fifteen years. There are additional prospects in many other nations. Neutron tests were vital during previous developments of materials and components for nuclear power applications, as reported in this conference series. For example a majority of the 140 papers in the Proceedings of the First WCNR are for the benefit of the nuclear power industry. Included are reviews of the diverse techniques being applied in Europe, Japan, the United States, and at many other centers. Many of those techniques are being utilized and advanced to the present time. Neutron radiography of irradiated nuclear fuel provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Applications include examination of nuclear waste, nuclear fuels, cladding, control elements, and other critical components. In this paper, the techniques developed and applied internationally for the nuclear power industry since the earliest years are reviewed, and the question is asked whether neutron test techniques can be of value in development of the present and future generations of nuclear power plants world-wide.

  10. Radiological protection procedures for industrial applications of computed radiography

    International Nuclear Information System (INIS)

    Aquino, Josilto Oliveira de

    2009-03-01

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  11. Charter of good practices in industrial radiography; Charte de bonnes pratiques en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This document describes good practices in the field of industrial radiography. After having presented the main prevention and radiation protection principles, the actors inside and outside of the company, and actors intervening during an operation subcontracting in industrial radiography, this report analyzes the activity: prerequisites for work preparation, prevention coordination, work preparation, transportation, work achievement, return on experience. It addresses personnel training and information, and the dosimetric and medical monitoring of technicians in industrial radiography. Some aspects are addressed in appendix: principles (justification, optimization, and limitation), regulations, intervention form, exposure form, and so on

  12. Radiation protection program of Petrobras in industrial radiography area

    International Nuclear Information System (INIS)

    Signorini, M.

    1988-01-01

    Industrial hygiene has as main purpose the preservation of employees physical integrity when exposed to certain agressive agents. PETROBRAS Industrial hygiene program forecasts preventive policies in several specific fields. For the ionizing radiations area it was developed the ''Radiologic Protection Program'' which also deals with specific actions in industrial radiography jobs. These actions are hereinafter presented. (C.M.) [pt

  13. Control by industrial radiography; Le controle par radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    Soares, V. [SIRAC, 78 - Maurepas (France)

    2008-07-01

    The author outlines the different precautions to be taken when using radiological instruments in an industrial context. This comprises specific arrangements and signalization of a determined area, regulatory requirements, technical constraints due to procedures, and so on. The author outlines that all these aspects need the implication of all the actors

  14. Radiation protection for industrial radiography in the aerospace industry

    International Nuclear Information System (INIS)

    Morgan, W.E.

    1980-01-01

    The Boeing Company employs 80 industrial radiographers, operates 90 radiation sources, and takes 10,000 exposures per month. This paper describes the major components of Boeing's radiation protection program: hazard analysis, facilities and equipment design, program administration, and evaluation. In the hazard analysis, each source of radiation is analyzed to determine its hazard and relationship to both man and the environment around it. Once the degree of the hazard is known, facilities and equipment are designed to contain the hazard. This can be anything from a four foot concrete shielded room for an industrial radiographic accelerator, to a piece of rope that isolates an Iridium-192 source during a field radiographic inspection on an aircraft. The administrative functions provide the necessary records, command media, and a radiation source certification program. This certification authorizes the source of radiation to be used under specific conditions agreed upon by both the Radiation Protection Organization and Industrial Radiography Management. The radiation protection program is evaluated through medical exams, personnel monitoring, and area radiation surveys. (H.K.)

  15. A methodology for radiological accidents analysis in industrial gamma radiography

    International Nuclear Information System (INIS)

    Silva, F.C.A. da.

    1990-01-01

    A critical review of 34 published severe radiological accidents in industrial gamma radiography, that happened in 15 countries, from 1960 to 1988, was performed. The most frequent causes, consequences and dose estimation methods were analysed, aiming to stablish better procedures of radiation safety and accidents analysis. The objective of this work is to elaborate a radiological accidents analysis methodology in industrial gamma radiography. The suggested methodology will enable professionals to determine the true causes of the event and to estimate the dose with a good certainty. The technical analytical tree, recommended by International Atomic Energy Agency to perform radiation protection and nuclear safety programs, was adopted in the elaboration of the suggested methodology. The viability of the use of the Electron Gamma Shower 4 Computer Code System to calculate the absorbed dose in radiological accidents in industrial gamma radiography, mainly at sup(192)Ir radioactive source handling situations was also studied. (author)

  16. Occupational exposure in Greek industrial radiography laboratories (1996-2003)

    International Nuclear Information System (INIS)

    More than 40 industrial radiography laboratories are operating in Greece using X-ray or gamma-ray sources and more than 250 workers occupationally exposed to ionising radiation in these facilities are monitored on a regular basis. This study presents the evolution of individual doses received by radiographers during the past years. The mean annual dose (MAD) of all workers as well as of exposed workers is estimated, and correlated to the types of laboratories and practices applied. The MAD of the exposed workers in industrial radiography is compared with the doses of workers in other specialties and with the doses of radiographers in other countries. Furthermore, the study attempts to propose dose constraints for the practices in industrial radiography, according to the BSS European directive and the relevant Greek radiation protection legislation. The proposed value was defined as the dose below which the annual doses of 75% of the exposed radiographers are expected to be included. (authors)

  17. Accidents in industrial radiography in Brazil from 2005 to 2010

    International Nuclear Information System (INIS)

    Lopes, Ricardo Tadeu

    2011-01-01

    Analysis of accidents occurring in industrial radiography in Brazil from 2005 until 2010 led to the study of the main characteristics of the events, their risks and dangers. This study outlines the main doubts on the subject, through a simplified analysis of the contents of high dose reports sent to CNEN by the companies that provide services for industrial radiography and from examining the growing number of radioactive sources for industrial radiography in Brazil, over this period. We classified the recorded events, as incidents, accidents, negligence, sabotage, and others, and studied their main consequences. We concluded that from 76 accidents that occurred during that period - 25 were real accidents, 13 minor accidents and 22 were inadvertent incidents. We found that the rate of growth in the number of sources is much greater than the rate of growth of accidents, with a ratio of 7.57 between them. The continuation of this study over some years, will allow the construction of a pyramid of accidents like the one developed by the Insurance Company of North America, specifically for industrial radiography to forecast the number of incidents and accidents that lead to serious or fatal injury. (author)

  18. A radiological health study of industrial gamma radiography in Canada

    International Nuclear Information System (INIS)

    1979-05-01

    As an occupational group, industrial radiographers receive radiation doses second only to reactor workers. This report is a result of a study carried out to research the causes for this relatively high dose and determine if and how it can be improved. The data presented herein were obtained from questionnaires and field visits to organizations involved in gamma radiography and from the Canadian National Dose Registry. Some applications of radiography such as pipeline work give rise to higher than average doses. When all safety measures are conscientiously aplied, the doses are reasonalbe. However, ignorance, carelessness and indifference account for much unnecessary exposure to radiation. (Auth)

  19. Development of Safety Kit for Industrial Radiography Application

    International Nuclear Information System (INIS)

    Mohd Noorul Ikhsan Ahmad; Amry Amin Abas

    2011-01-01

    A safety kit for industrial radiography has been developed. The safety kit that consist of a set of technical rod and various size of base that can be used in radiograph of pipe with diameter between half and one and half inch with utilization of collimator. With the kit, radiographers will not having anymore problem to use collimator in their work. The paper discuss about the technical measures of the safety kit and the importance of introducing it to the industry. (author)

  20. Industrial application of muon radiography and development of small accelerator

    International Nuclear Information System (INIS)

    Nagamine, Kanetada

    2003-01-01

    There have been some applications to investigate the inner part of car and reactor. In this paper, the research method of the inner part of apparatus is discussed and development of small accelerator was investigated. The general theory of radiography, characteristics of muon radiography and its application, industrial application of muon radiography and small accelerator are stated. The muon radiography is proposed to the direct investigation method of the inner part of industrial instruments. The three points have to be considered as followings; 1) muon is necessary to diagnose the important industrial instruments, 2) adjacent or movable muon sources have to be set. A small proton accelerator with from 0.5 to 1Gev of Ep and Ip > 1 μA is reasonable. Muon source with large solid angle muon channel, ultra-low velocity μ + ion source and reacceleration is required. 3) A transmitted image with less than mm resolution of equipment with some m of thickness is able to be obtained. (S.Y.)

  1. Findings of the inspection grading system on industrial radiography

    International Nuclear Information System (INIS)

    Gloria Doloressa

    2011-01-01

    The use of industrial radiography techniques evolve rapidly and widely. Various jobs in industry require the examination of welding techniques / connecting pipes and metal construction. The use of industrial radiography is one type of utilization of nuclear energy must get control so that its use does not cause harmful impacts to worker safety, community, and environment. Regulations is done through inspections, in order to supervise the observance of the terms in the licensing and legislation in the field of nuclear safety. The main purpose of inspection is to ensure the utilization of radiation sources of radiation have been used with. Findings of the inspection is a decline in the performance of licensees in meeting safety requirements. The Grading System to the findings of the inspection needs to be done to improve the effectiveness and efficiency of inspection, and it is expected that the company can improve the management of radiation safety. (author)

  2. INDUSTRIAL RADIOGRAPHY COURSE, INSTRUCTOR'S GUIDE, VOLUME 1.

    Science.gov (United States)

    Texas A and M Univ., College Station. Engineering Extension Service.

    THE PURPOSE OF THE GUIDE IS TO GIVE MAXIMUM ASSISTANCE TO INSTRUCTORS IN PLANNING THE TRAINING OF LICENSED INDUSTRIAL RADIOGRAPHERS. IT WAS DEVELOPED BY THE ENGINEERING EXTENSION SERVICE, TEXAS AGRICULTURAL AND MECHANICAL UNIVERSITY, COLLEGE STATION, TEXAS. THE 21 UNITS INCLUDE (1) INDUSTRIAL APPLICATIONS, (2) NONDESTRUCTIVE TESTING METHODS, (3)…

  3. Low cost automatic cable winder for industrial radiography projector

    International Nuclear Information System (INIS)

    Nor Arymaswati Abdullah; Abdul Nassir Ibrahim; Shaharudin Sayuti; Glam Hadzir Patai Mohamad; Masrol Nizam Salleh; Arshad Yasin; Nur Aira Abdul Rahman

    2009-04-01

    Radiography is a well-established technique that is widely used to detect internal flaws in welds, castings and to check for misconstruction in assemblies. In general it is to verify weld quality in engineering structures such as the fabrication of pressure vessels, pipelines and storage tanks. It can be used on all metals, from light metals such as aluminium to dense metals such as lead. One of the techniques is industrial radiography projector. Industrial radiography projector is used to store radioactive materials when it is not required to expose the material under test. The projector will come together with a guide tube and control unit (cable winder and drive cable). When the source is to be used to radiograph an item, the cable winder will wind-out the source from projector to the desired location through a guide tube. Upon completion of the work the source will be retracted back into its safe shielded position in this projector. In common procedure, the operator has to be close to the exposures projector while wind-out or wind-in the source from and into the projector. This made the radiography operator receive the highest exposure among the radiation operator and this agreed by IAEA. This paper describes a winder cable that can be used to guide the movement of radiography source out of and into the projector that can be controlled by a remote control system. The system comprises of a gear, reversible motor and low frequency automatic controller. This system is powered by DC chargeable battery. (author)

  4. Analysis of radiation protection on industrial radiography open facilities

    International Nuclear Information System (INIS)

    Leocadio, Joao C.; Tauhata, Luiz; Crispim, Verginia R.

    2000-01-01

    This work had the objective to analyze the open facilities or mobile industrial radiography to obtain the distribution of doses in the radiographers, to evaluate the radiological conditions and the operational procedures, besides to present proposed for the reference levels and to esteem the potential exposure. The results of the additional monitoring revealed an improvement of the radiation protection conditions in the open facilities and the risk of potential exposure was reduced. With relationship to the radiation protection procedures, the accompaniment of the radiographic testing verified that most of the problems was solved. The advantage of the proposed reference levels is that the supervisors would enlarge the frequency of audits to accomplish the investigations and interventions. The mobile industrial radiography with 'bunkers' presented distributions with 95% of the doses below 0,2 mSv and the distributions of the facilities with cordoned area they had 75% of the doses below 0,4 mSv. (author)

  5. Human performance analysis of industrial radiography radiation exposure events

    International Nuclear Information System (INIS)

    Reece, W.J.; Hill, S.G.

    1995-01-01

    A set of radiation overexposure event reports were reviewed as part of a program to examine human performance in industrial radiography for the US Nuclear Regulatory Commission. Incident records for a seven year period were retrieved from an event database. Ninety-five exposure events were initially categorized and sorted for further analysis. Descriptive models were applied to a subset of severe overexposure events. Modeling included: (1) operational sequence tables to outline the key human actions and interactions with equipment, (2) human reliability event trees, (3) an application of an information processing failures model, and (4) an extrapolated use of the error influences and effects diagram. Results of the modeling analyses provided insights into the industrial radiography task and suggested areas for further action and study to decrease overexposures

  6. Application of digital image processing to industrial radiography

    International Nuclear Information System (INIS)

    Bodson; Varcin; Crescenzo; Theulot

    1985-01-01

    Radiography is widely used for quality control of fabrication of large reactor components. Image processing methods are applied to industrial radiographs in order to help to take a decision as well as to reduce costs and delays for examination. Films, performed in representative operating conditions, are used to test results obtained with algorithms for the restauration of images and for the detection, characterisation of indications in order to determine the possibility of an automatic radiographs processing [fr

  7. Radioactive sealed sources production process for industrial radiography

    International Nuclear Information System (INIS)

    Santos, Paulo de S.; Ngunga, Daniel M.G.; Camara, Julio R.; Vasquez, Pablo A.S.

    2017-01-01

    providing products and services to the private and governmental Brazilian users of industrial radiography and nucleonic control systems. Radioactive sealed sources are commonly used in nondestructive tests as radiography to make inspections and verify the internal structure and integrity of materials and in nucleonic gauges to control level, density, viscosity, etc. in on-line industrial processes. One of the most important activities carried out by this laboratory is related to the inspection of source projectors devices used in industrial radiography and its constituent parts as well as remote handle control assembly drive cable and guide tube systems. The laboratory also provide for the users iridium-192, cobalt-60 and selenium-75 sealed sources and performs quality control tests replacing spent or contaminated radiative sources. All discard of radioactive source is treated as radioactive waste. Additionally, administrative and commercial processes and protocols for exportation and transport of radioactive material are developed by specialized departments. In this work are presented the mean processes and procedures used by the Sealed Source Production Laboratory such as the arrival of the radioactive material to the laboratory and the source projectors, mechanical inspections, source loading, source leaking tests, etc. (author)

  8. Radioactive sealed sources production process for industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Paulo de S.; Ngunga, Daniel M.G.; Camara, Julio R.; Vasquez, Pablo A.S., E-mail: psantos@ipen.br, E-mail: hobeddaniel@gmail.com, E-mail: jrcamara@ipen.br, E-mail: pavsalva@ipen.br [Instituto de Pesquisas Energética s e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    providing products and services to the private and governmental Brazilian users of industrial radiography and nucleonic control systems. Radioactive sealed sources are commonly used in nondestructive tests as radiography to make inspections and verify the internal structure and integrity of materials and in nucleonic gauges to control level, density, viscosity, etc. in on-line industrial processes. One of the most important activities carried out by this laboratory is related to the inspection of source projectors devices used in industrial radiography and its constituent parts as well as remote handle control assembly drive cable and guide tube systems. The laboratory also provide for the users iridium-192, cobalt-60 and selenium-75 sealed sources and performs quality control tests replacing spent or contaminated radiative sources. All discard of radioactive source is treated as radioactive waste. Additionally, administrative and commercial processes and protocols for exportation and transport of radioactive material are developed by specialized departments. In this work are presented the mean processes and procedures used by the Sealed Source Production Laboratory such as the arrival of the radioactive material to the laboratory and the source projectors, mechanical inspections, source loading, source leaking tests, etc. (author)

  9. Radiography

    Science.gov (United States)

    Gardner, C. G.

    1973-01-01

    Radiography is discussed as a method for nondestructive evaluation of internal flaws of solids. Gamma ray and X-ray equipment are described along with radiographic film, radiograph interpretation, and neutron radiography.

  10. Routine check and annual maintenance for industrial radiography gamma projector

    International Nuclear Information System (INIS)

    Shaharudin Sayuti; Abdul Nassir Ibrahim; Sukhri Ahmad; Arshad Yassin; Mohd Junaidi Jaapar; Khairul Anuar Mohd Salleh; Abdul Razak Hamzah

    2009-04-01

    The main objective of this paper is to share some experience pertaining to gamma projector maintenance programme. In Malaysia there are more than 100 gamma projectors, which need to be maintenance annually. Most of these projectors are Tech-Ops 660 series portable gamma radiography systems, which are used primarily for industrial radiography. The portability feature of the system provides both a safe means of transporting the radioactive source and operating flexibility, particularly useful in areas where access is limited. Generally, the national authorised service centre carries out the annual inspection of this system. In Malaysia, Malaysian Nuclear Agency has been recognised as the National Gamma Projector Maintenance Centre by the Atomic Energy Licensing Board (AELB). In this paper, a brief review of the design and operation is included in the discussion of the maintenance procedure, limitations and improvements of the gamma projector maintenance programme. (author)

  11. Faults on gamma projector Model 660 series for industrial radiography

    International Nuclear Information System (INIS)

    Sukhri Ahmad; Arshad Yassin; Saidi Rajab; Shaharudin Sayuti; Abd Nassir Ibrahim; Abd Razak Hamzah

    2005-01-01

    The main objective of this paper is to present MINTs experience pertaining to gamma projector maintenance activity. In Malaysia there are more than 100 gamma projectors that need to be maintained annually. Most of these projectors are of Tech-Ops Model 660 series portable gamma radiography systems, primarily for industrial radiography. The portability feature of the system provides both a safe means of transporting the radioactive source and operating flexibility, particularly useful in areas where access is limited. In Malaysia, Malaysian Institute for Nuclear Technology Research (MINT) has been approved as the National Gamma Projector Maintenance Centre by the Atomic Energy Licensing Board (AELB). This approval entitles MINT to undertake projector maintenance activity for all projectors throughout the country. Within 10 years of operation, MINT has dealt with thousands of projectors. (Author)

  12. Contemporary practice education: Exploring student perceptions of an industrial radiography placement for final year diagnostic radiography students

    International Nuclear Information System (INIS)

    Wareing, A.K.; Henderson, I.

    2015-01-01

    Introduction: There is a paucity of evidence in diagnostic radiography evaluating a career path into industrial imaging despite several higher education institutes stating this route as a career option on graduation. The link between a career in industrial radiography and diagnostic routes is unknown although there are anecdotal examples of individuals transferring between the two. Successfully obtaining a first post job following graduation in diagnostic radiography can be challenging in the current financial climate. A partnership was formed with an energy sector company that offered non-destructive testing/non-destructive evaluation (NDT/NDE) employing industrial radiographic technicians. Method: As an initial pilot, 5 (n = 5) final year diagnostic radiography students visited an industrial radiography site and underwent theoretical and practical training. Following this placement they engaged in a focus group and the student perceptions/responses were explored and recorded. Results: Common themes were identified and categorised via a thematic analysis. These were; radiation safety, physics and technology, widening access, graduate attributes/transferable skill sets and working conditions. Conclusion: Student discussion focussed around the benefits of working conditions in healthcare, the value of technology, safety and physics education in alternative placements and the transferability of skills into other/industrial sectors (e.g. NDT/NDE). Contemporary practice placements are a useful pedagogical approach to develop complex conceptual theoretical constructs, such as radiation physics. An in depth evaluation between the two industries skill sets is postulated. Additionally, this could offer alternative/emerging roles to interested diagnostic radiographers potentially meeting the skill shortage in industrial radiography. - Highlights: • Research in this area is novel. No evidence could be found to evaluate the links. • Students had theoretical

  13. Overview of Brazilian industrial radiography accidents with cutaneous radiation syndrome

    International Nuclear Information System (INIS)

    Lima, C.M.A.; Silva, F.C.A. da

    2017-01-01

    It is well documented that industrial radiography is related to radiological accidents, which makes it the highest potential risk for human health. More than 80 radiological accidents happened in the world that includes 6 Brazilian accidents with Cutaneous Radiation Syndrome. Five of them happened with 192 Ir and one with 60 Co radioactive sources. Nineteen members of the public and 8 radiographers were involved. All of them suffered severe hands and fingers injuries. The Brazilian radiological accident happened in 1985 with 16 persons is analyzed showing causes, consequences, radiation doses and lessons learned. (author)

  14. 10 CFR 34.61 - Records of the specific license for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of the specific license for industrial radiography. 34.61 Section 34.61 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Recordkeeping Requirements § 34.61...

  15. 10 CFR 34.42 - Radiation Safety Officer for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation Safety Officer for industrial radiography. 34.42... SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.42 Radiation Safety Officer for industrial radiography. The RSO shall ensure that radiation safety activities...

  16. 10 CFR 34.20 - Performance requirements for industrial radiography equipment.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Performance requirements for industrial radiography equipment. 34.20 Section 34.20 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Equipment § 34.20 Performance...

  17. Application of neutron radiography to some industrial components

    International Nuclear Information System (INIS)

    Tazawa, Shuichi; Nakanii, Takehiko; Tarumi, Yuji; Yano, Munehiko; Okamura, Hiroyuki.

    1987-01-01

    Sumitomo Heavy Industries, Ltd. developed reliable neutron radiography system using cyclotron, and tested to observe inner liquid in some industrial components such as shock absorbers for automobiles, aircraft fuel injection pumps and plastic extruders in operating condition. The equipment for neutron fluorescopy is composed of a sub-compact cyclotron and a LiF/ZnS(Ag) screen converter to be viewed by a Silicon Intensifier Target (SIT) TV camera. Stereoscopic view was examined by a robotic arm and a pair of stereo-glass. The stereoscopic images were photographed by few degrees rotation of object and stored at each field of one TV frame of standard NTSC system. The image reconstruction was performed by viewing through a pair of Plumbum Lanthanum Zirconate Titanate (PLZT) glass which synchronizes at the TV field signal and opens left and right eye altermately. (author)

  18. Resolution 12/2004 Guideline for implementation of safety regulations in the practice of industrial radiography

    International Nuclear Information System (INIS)

    2004-01-01

    1. This guide is intended to clarify, in relation to its application in practice Industrial Radiography, the provisions of: a) Joint Resolution CITMA-MINSAP, of December 15, 2002, Regulation: B asic Radiation Safety Standards , hereinafter Regulation NBS; b) Resolution No. 25/98 of CITMA Regulation. A uthorization Practices Associated with the use of ionizing radiation , hereinafter Resolution 25/98; c) Resolution 121/2000 CITMA Regulation: F or the Safe Transport of Radioactive materials , hereinafter Resolution 121/2000; and in d) Joint Resolution CITMA-MINSAP, Regulation: S election, Training and Authorization of personnel performing Employment Practices Associated Radiation Ionizing . 2. For the purposes of applying this Guide considers the practice of Industrial Radiography includes the following techniques: a) Industrial Radiography with use of gamma radiation sources; b) crawler radiography equipment; and c) Industrial Radiography with X-rays

  19. Establishing local rules for industrial radiography practice using radionuclides

    International Nuclear Information System (INIS)

    Ambrosio, N.

    2012-04-01

    Industrial Radiograph used for non-destructive testing of material or equipment constitutes one of the most important applications of radiation sources. Non-destructive testing (NDT) provides a means of verifying the physical integrity of equipment and structures such as vessels, pipes, welded joints, castings and other devices. The physical integrity of such equipment and structures affects not only the safety and quality of the products but also the protection of workers, the public and the environment, as operator of these devises could result in accidents. The development and maintenance of safety culture in an operating organization has to cover management systems, policies, responsibilities, procedures and organizational arrangements.The essence is to control radiation hazard, optimize radiation protection to prevent or reduce exposures and mitigate the consequences of accidents and incidents. To achieve high degree of professionalism, appropriate national and organizational infrastructure is required in addition to ensure effective training of workers, compliance with safety culture and effective quality control. Therefore, this report presents a model Local Rules and procedures necessary for the safe operation of Industrial Radiography devises in order to protect worker, the public and the environment. The model has been developed from examples from published reports. (author)

  20. The Information System on Occupational Exposure in Medicine, Industry and Research (ISEMIR): Industrial Radiography

    International Nuclear Information System (INIS)

    2014-08-01

    Industrial radiography work is often carried out under difficult working conditions, such as in confined spaces, in extreme cold or heat, or during the night. Working under such adverse conditions might result in operational situations in which occupational radiation protection may be compromised. Experience shows that incidents involving industrial radiography sources have sometimes resulted in high doses to workers, causing severe health consequences such as radiation burns and, in a few cases, death. It has been long known that there is significant potential for industrial radiography personnel to receive non-trivial occupational exposure. However, a global perspective is lacking, as is the availability of a systematic means for improving occupational radiation protection in industrial radiography worldwide. In 2006, the IAEA published IAEA Safety Standards Series No. SF-1, Fundamental Safety Principles, jointly sponsored by the European Atomic Energy Community, the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organization (ILO), the International Maritime Organization, the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO), the United Nations Environment Programme (UNEP) and the World Health Organization (WHO). That publication sets out the fundamental safety objective and principles of protection and safety. In 2014, the IAEA published IAEA Safety Standards Series No. GSR Part 3, Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards (the BSS), jointly sponsored by the European Commission, the FAO, the ILO, OECD/NEA, the PAHO, UNEP and the WHO. The BSS sets out the requirements that are designed to meet fundamental safety objectives and to apply the principles specified in IAEA Safety Standards Series No. SF-1. The establishment of safety requirements and provision of guidance on occupational radiation protection is a major component of the support

  1. Factors related to the Ecran-Film contact in the industrial radiography

    International Nuclear Information System (INIS)

    Raets, G.

    1983-01-01

    The relative importance of ecram-film for industrial radiographies is discussed, and the results are presented after an extensive evaluation of a new combination type of ecran-film prepared in a vacuum. (E.G.) [pt

  2. Evaluation of digital detector arrays systems for industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Aline S.S.; Oliveira, Davi F.; Gomes, Célio S.; Azeredo, Soraia R.; Lopes, Ricardo T., E-mail: aline@lin.ufrj.br, E-mail: davi@lin.ufrj.br.br, E-mail: celio@lin.ufrj.br, E-mail: soraia@lin.ufrj.br, E-mail: ricardo@lin.ufrj.br, E-mail: davi.oliveira@uerj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentação Nuclear

    2017-07-01

    Digital Detector Arrays (DDA) or Flat Panel Detector (FPD) is a highly efficient technique that is used in nondestructive testing of internal features of an object. The evaluation of DDA systems for industrial radiography is important to ensure the image quality and to enables long-term stability of this system. This evaluation is specified by ASTM E2737 - 10, which describes the fundamental parameters of DDA systems to be measured. The tests require the usage of either the five-groove wedge or the duplex plate phantom with separate Image Quality Indicators (IQIs). The purpose of this work was evaluate the radiographic performance achieved using both techniques in two DDA systems manufactured by GEIT: DXR250P and DXR250V, which have thallium-doped cesium iodide (CsI:Tl) and terbium-doped gadolinium oxysulfide (Gd{sub 2}O{sub 2}S:Tb - GOS) scintillators, respectively. For this purpose, it was used an X-ray equipment as radiation source. The image quality parameters analyzed were Image Lag (IL), Offset Level (OL), Bad Pixel distribution, Burn In (BI), Spatial Resolution (SR), Material Thickness Range (MTR), Contrast Sensitivity (CS), Signal Level (SL) and Signal-to-Noise Ratio (SNR). As result of this study, has been observed that the use of the five-groove wedge phantom made the measurements to become easier to execute. Regarding the DDA system, the DXR250P presented more IL and BI, but produced images with better CS and SNR and needed a dose almost twice smaller than the DXR250V to achieve a similar SL. (author)

  3. The 10 recommendations for prevention of radiation accidents in industrial gamma radiography

    International Nuclear Information System (INIS)

    Souza, Luana Silva de

    2015-01-01

    The Industrial Gamma Radiography, as part of Industrial Radiography, stands out as the most widespread and plays an important role in the quality control of different materials and devices. However, IAEA classifies industrial gamma radiography in the Category 2 as very dangerous due to the radiological risk caused by the use of high activity radioactive sources. In March, 2012, a Brazilian Workshop on Prevention of Industrial Gamma Radiography Accident was performed by DIAPI/CNEN with the objective of disseminating knowledge about radiological accidents with radioactive sources in this application. During this Workshop, IRD/CNEN conducted a survey with 75 participants using a form with 22 recommendations to prevent radiological accidents, aiming to select the most voted. This present work aims to perform a detailed statistical study to define the Top 10 Recommendations for industrial gamma radiography operator avoids radiological accidents and to prepare a brochure with these top 10 recommendations to be distributed to all industrial gamma radiography radiation workers. Data analysis was performed using the statistical method 'Frequency Distribution', among the 75 participants categorized as General, RPO, and Other Workers of the area. The results were obtained for each category, accounting for the total of 22 recommendations in its percentage and number of votes, and the top 10 recommendations were defined to prevent radiological accidents. The first place and most important recommendation is 'Always use a personal alarm monitor throughout the work'. One of the conclusions is that the brochure with the Top 10 Recommendations shows to be understandable and useful for dissemination and training of radiation workers to avoid radiological accidents in industrial gamma radiography. (author)

  4. Radiological protection procedures for industrial applications of computed radiography; Procedimentos de protecao radiologica em aplicacoes industriais da radiografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Josilto Oliveira de

    2009-03-15

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  5. Computer radiography - indirect digital radiography

    International Nuclear Information System (INIS)

    Jezierski, G.

    2008-01-01

    Implementation of the new European standards for industrial radiography with the use of storage phosphor imaging plates will result in the arousing of interest among numerous laboratories in non-destructive testing with application of the new method of testing to replace conventional radiography used so far, i.e. film radiography. Computer radiography is quite commonly used for medical radiography, where the fundamental problem consists in reduction of the radiation dose during the examination of a patient. However, it must be kept in mind that industrial applications have a little bit different requirements when compared with medical radiography. The article describes only new method for radiographic testing. (author)

  6. Performance evaluation of the conventional Brazilian industries radiation protection in the small industrial gauges and industrial radiography areas

    International Nuclear Information System (INIS)

    Santos, Joyra Amaral dos

    1999-08-01

    This works evaluates by punctuation the performance in conventional Brazilian industries radiation protection area which make use of small industrial gauges and industrial radiography. It proposes, procedures for industry self-evaluation, besides a new radiation protection plans pattern for the small industrial gauges area. The data source where inspection reports of Dosimetry Radiation Protection Institute/Nuclear Energy Commission conventional Brazilian industries' radiation protection plans, beyond visitation to the inspection place. The performance evaluation has been realized both in the administrative and operational aspects of the industries. About of 60% of the industries have a satisfactory register control which does not happen to the operational control. The performance evaluation advantage is that industries may self-evaluate, foreseeing Dosimetry Radiation Protection Institute's regulation inspections, correcting its irregularities, automatically improving its services. The number of industries which have obtained satisfactory performance in both areas is below 70%, both in administrative and operational aspects. Such number can be considered a low one as it is radiation protection. The procedures propose in this work aim to improve such a situation. (author)

  7. Occupational exposure in Greek industrial radiography laboratories (2004-2006) and comparison of doses with other industrial applications

    International Nuclear Information System (INIS)

    Tritakis, P.; Papadomarkaki, E.; Economides, S.; Carinou, E.; Hourdakis, C.; Kamenopoulou, V.; Dimitriou, P.

    2008-01-01

    Full text: In this study the Mean Annual Dose (MAD) of all industrial radiography workers in Greece for the time period 2004-2006 is evaluated and correlated to the practice and type of equipment used. All data used in this study come from the National Dose Registry Information System of the Greek Atomic Energy Commission. The present study constitutes the follow up of two previous studies, where a Dose Constraint (DC) for industrial radiography in Greece, equal to 4.0mSv was introduced for the first time. The introduction and systematic use of a dynamic DC value aims to optimize common working practices through a continuous decrease of occupational doses. In the current work a further decrease in the industrial radiography personnel doses is observed and the factors leading to this result are analyzed. Finally, the estimated MAD value for exposed workers in industrial radiography is compared to the ones corresponding to workers in other industrial applications involving the use of ionizing radiation

  8. Application Of Flash X-Ray Radiography To Problems In The Pulp And Paper Industry

    Science.gov (United States)

    Farrington, Theodore E.

    1988-02-01

    The use of flash x-ray radiography to investigate high speed multiphase flows is demonstrated. Both fundamental and practical problems of interest to the pulp and paper industry are used as examples. More specifically, studies of concentrated fiber suspension flows, kraft black liquor sprays and impulse drying are discussed.

  9. Working safely in gamma radiography. A training manual for industrial radiographers

    International Nuclear Information System (INIS)

    McGuire, S.A.; Peabody, C.A.

    1982-09-01

    This manual is designed for classroom training in working safely in industrial radiography using gamma sources. The purpose is to train radiographers' assistants to work safely as a qualified gamma radiographer. The contents cover the essentials of radiation, radiation protection, emergency procedures, gamma cameras, and biological effects of radiation

  10. Licensing for industrial gamma and X-ray radiography installation in Peru

    International Nuclear Information System (INIS)

    Medina G, E.

    1988-01-01

    According the regulations for ionizing radiation source installations an application to the Peruvian National Authority should be forwarded in order to get the construction on operation license both industrial gamma and X-ray. Radiography is considered as well as personnel aspects. The proceedings are described

  11. Conditions for radiation protection in industrial radiography; Vilkaar om straalevern ved industriell radiografi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    The leaflet specifies radiation protection requirements for industrial radiography in Norway. The regulations are directed towards companies using or distributing sealed radioactive sources, x-ray equipment or accelerators in non-destructive material testing (NDT). Technical requirements to the equipment, as well as administrative requirements for use, licensing, qualifications, handling of accidents etc. are given. (Author)

  12. Implantation of licensing norm for industrial radiography installations - Norm CNEN-NE-604 Rev.1

    International Nuclear Information System (INIS)

    Heilbron Filho, P.F.L.; Oliveira, S.M.V. de.

    1988-04-01

    The results of audits carried out by DIN/CNEN (Department of Nuclear Installations) in firms of Rio de Janeiro and Sao Paulo, Brazil, that use industrial radiography for implantation of the norm of installation licensing, are presented. (M.C.K.) [pt

  13. Working safely in gamma radiography. A training manual for industrial radiographers

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, S.A.; Peabody, C.A.

    1982-09-01

    This manual is designed for classroom training in working safely in industrial radiography using gamma sources. The purpose is to train radiographers' assistants to work safely as a qualified gamma radiographer. The contents cover the essentials of radiation, radiation protection, emergency procedures, gamma cameras, and biological effects of radiation. (ACR)

  14. Assessment and prevention of the professional risks in the operations of industrial radiography

    International Nuclear Information System (INIS)

    Pizzorno, M.; Paul, D.; Coletti, F.; Sari Minodier, I.; Azzopardi, G.; Klemenic, O.; Botta, A.

    2006-01-01

    Industrial radiography is a nocturnal activity, hazardous and little known; it is among the professions the most exposed to ionizing radiation. This study analyse the doses, received the industrial radiographers, their workplace conditions and organization of their tasks. Dosimetry observations on site, together with calculations using the Mercurad code, allowed mean values for reference doses for all the work (including transport, gammatron manipulation, collimator manipulation, shooting) to be established. These value were integrated into a table entitled 'reference doses' in order to provisionally evaluate the doses received by the operators. Distances for security zone demarcation, so as to forbid access to non exposed personnel during shooting, were evaluated. Assessment of the professional risks for industrial radiography, taking into account all the risks (radiological and others), has been made and is under evaluation. This led to measures for prevention based on the material used (collimator, tripod, gamma-stops), on the organization and the conditions of work (for example, time limits permitting a prior visit to the site and preparation for radiography, suitable scaffolding, sufficient lighting, siting of shootings). These prevention measure will be integrated into the new charter of good practice in industrial radiography in the Provence Alpes Cote d'Azur region (south of France). (authors)

  15. Industrial Assessment Center (IAC) Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Gopalakrishnan, Bhaskaran [West Virginia Univ., Morgantown, WV (United States); Nimbalkar, Sachin U. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wenning, Thomas J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Thirumaran, Kiran [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-04-01

    IAC Operations Manual describes organizational model and operations of the Industrial Assessment Center (IAC), Center management activities, typical process of energy assessment, and energy assessment data for specific industry sectors.

  16. Physical protection of mobile radioactive sources commonly used in the well logging and industrial radiography industries

    International Nuclear Information System (INIS)

    Barlow, Maegon E.

    2016-01-01

    The mission of the U.S. Department of Energy/National Nuclear Security Administration's (NNSA) Office of Radiological Security (ORS) is to protect high-activity radiological materials around the globe. ORS works domestically within the United States and collaborates with over 80 countries to protect medical, industrial, research and other radiological sources from being used by malicious actors in a radiological dispersal device (RDD) or radiation exposure device (RED). One area of specific concern is mobile radioactive sources, such as those used in radiography to inspect welds or metal integrity, and those in the oil and gas industry to characterize exploration and production wells in pursuit of oil caches. These mobile radiological sources are of sufficient Curie quantities to be categorized as desirable sources for malicious actors. This presentation will provide an overview of a mobile source tracking system developed by ORS in conjunction with Pacific Northwest National Laboratory (PNNL), and will discuss how the system can contribute to source security, as well as next steps to pilot this technology

  17. A mobile-device based applications software for industrial gamma radiography

    International Nuclear Information System (INIS)

    Acharya, Rajesh V.; Mitra, Anant; Kumar, Saroj; Lakshminarayana, Y.; Walinjkar, Parag; Kumar, Umesh

    2013-12-01

    The paper discusses a mobile device based application software for performing calculations required in industrial film radiography using radioisotope sources. The application enables the user to find residual life of a radioactive source, saving multiple source details in the phone memory, exposure time calculation required in gamma radiography and running multiple countdown clocks for accurate and convenient counting of exposure time. The application is also able to provide vibrating and audio alarms when the countdown finishes, automatic SMS facility to multiple users informing details of low activity sources in custody and cordon-off distances for open-source radiography. The application has been developed to work under Android, I-phone (Apple), Blackberry (RIM), Windows, Symbian operating systems and J2ME enabled feature phones. A simplified version of this application with limited features runs on java enabled low-cost mobile phones and tablets. (author)

  18. Radiation safety aspects in application of isotopes for industrial radiography in Bangladesh

    International Nuclear Information System (INIS)

    Bakht, D.

    1997-01-01

    Industrial Radiography arose out of the widespread applications of X-rays pioneered by Roentgen about 100 years back. It is routinely used in studying the integrity of structural materials and like most countries in the world, its use in Bangladesh is increasing at a faster rate. This is because Bangladesh is a developing country of 3rd world and in the backdrop of agrarian poverty ridden economy, its population may exceed 125 millions by 2000 AD, leaving some 12 millions people unemployed. To support them, therefore, immense activities are activated in different sectors. Accordingly, increasing importance on NDT is given and in most cases particular application of Gamma radiography is preferred using Iridium Isotope Ir-192. Consequently the points of implications of isotopes are in Open Field and Inservice Inspection Radiography, Handling of Radiation Emergencies, Safe Transport of Radioactive Materials and Hazardous Effects and Risk of Ionizing Radiation, etc. Accordingly over exposure of Ir-192 Radionuclides, Accidents and Unusual Occurrences: Case Studies, Training Courses on Safety and Regulation of Sealed Sources, Licenses for Radiography Operation including Safe Disposal of Isotopes are the salient issues to be viewed in appropriate perspectives. The role played by Bangladesh Atomic Energy Commission and Bangladesh Society for NDT in collaboration with other members of the international committee for NDT are furthering the safe industrialization process

  19. Code of practice for the safe use of industrial radiography equipment (1989)

    International Nuclear Information System (INIS)

    1989-12-01

    This code supersedes the Code of Practice for the control and safe handling of sealed radioactive sources use din industrial radiography, published by the National Health and Medical Research Council (NHMRC) in 1968. It differs significantly from the former code because radiation protection practice and recommended standards have changed. The code covers the design, construction and requirements for the safe use of X-radiography equipment and gamma-radiography equipment. It provides illustrative working rules, detailed emergency procedures and comprehensive responsibilities and duties for all personnel involved in supplying and using industrial radiography equipment. The code details those equipment requirements, personnel requirements and work practices that the NHMRC considers necessary to keep exposures to ionizing radiation as low as reasonably achievable. Some equipment and facilities currently in use may not meet all of the mandatory requirements of this code. These requirements have been included in the code to encourage progress towards future compliance in the expectation that, in the interim, statutory authorities will apply them with discretion. 9 refs., tabs., ills

  20. Radiation safety aspects in application of isotopes for industrial radiography in Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Bakht, D. [Titas Gas Transmission and Distribution Company, Dhaka (Bangladesh)

    1997-10-01

    Industrial Radiography arose out of the widespread applications of X-rays pioneered by Roentgen about 100 years back. It is routinely used in studying the integrity of structural materials and like most countries in the world, its use in Bangladesh is increasing at a faster rate. This is because Bangladesh is a developing country of 3rd world and in the backdrop of agrarian poverty ridden economy, its population may exceed 125 millions by 2000 AD, leaving some 12 millions people unemployed. To support them, therefore, immense activities are activated in different sectors. Accordingly, increasing importance on NDT is given and in most cases particular application of Gamma radiography is preferred using Iridium Isotope Ir-192. Consequently the points of implications of isotopes are in Open Field and Inservice Inspection Radiography, Handling of Radiation Emergencies, Safe Transport of Radioactive Materials and Hazardous Effects and Risk of Ionizing Radiation, etc. Accordingly over exposure of Ir-192 Radionuclides, Accidents and Unusual Occurrences: Case Studies, Training Courses on Safety and Regulation of Sealed Sources, Licenses for Radiography Operation including Safe Disposal of Isotopes are the salient issues to be viewed in appropriate perspectives. The role played by Bangladesh Atomic Energy Commission and Bangladesh Society for NDT in collaboration with other members of the international committee for NDT are furthering the safe industrialization process

  1. New development in the certification of a component radiation protection officer in industrial radiography

    International Nuclear Information System (INIS)

    Ismail Bahari; Azwar, M.H.; Mohd Pauzi, M.S.

    2001-01-01

    The appointment of a Radiation protection Officer (RPO) by companies for activities related to the use of Atomic Energy, including Industrial Radiography is mandated under regulation 23 of the Radiation Protection (Basic Safety Standards) Regulations 1988. The regulations categorically requires the appointment of a competent person to help ensure radiation safety at work. Definition of competency has been spelt out in the regulations and this is translated to include having been trained and tested through examination by the AELB and be able to carry out the duties and responsibilities prescribed by the Act and Regulations. This paper discusses the development in the certification of RPO in the field of industrial radiography and what the new RPO certification scheme together with the Certification of RPO standard (LEMI/TEK/44) will do to increase competency as well as the market value of future RPOs. (Author)

  2. Tests of cosmic ray radiography for power industry applications

    Directory of Open Access Journals (Sweden)

    J. M. Durham

    2015-06-01

    Full Text Available In this report, we assess muon multiple scattering tomography as a non-destructive inspection technique in several typical areas of interest to the nuclear power industry, including monitoring concrete degradation, gate valve conditions, and pipe wall thickness. This work is motivated by the need for imaging methods that do not require the licensing, training, and safety controls of x-rays, and by the need to be able to penetrate considerable overburden to examine internal details of components that are otherwise inaccessible, with minimum impact on industrial operations. In some scenarios, we find that muon tomography may be an attractive alternative to more typical measurements.

  3. Preliminary results from the application of risk matrix method for safety assessment in industrial radiography

    International Nuclear Information System (INIS)

    Lopez G, A.; Cruz, D.; Truppa, W.; Aravena, M.; Tamayo, B.

    2015-09-01

    Although the uses of ionizing radiation in industry are subject to procedures that provide a high level of safety, experience has shown that equipment failure, human errors, or the combination of both that can trigger accidental exposures may occur. Traditionally, the radiation safety checks whether these industrial practices (industrial radiography, industrial irradiators, among others) are sufficiently safe to prevent similar accidental exposures already occurred, so that becomes dependent on the published information and not always answers questions like: What other events can occur, or what other risks are present? Taking into account the results achieved by the Foro Iberoamericano de Organismos Reguladores Radiologicos y Nucleares, its leading position in the use of techniques of risk analysis in radioactive facilities and the need to develop a proactive approach to the prevention of accidents arising from the use of ionizing radiations in the industry, it intends to apply the risk analysis technique known as Risk Matrix to a hypothetical reference entity for the region in which industrial radiography is performed. In this paper the results of the first stage of this study are shown, that is the identification of initiating events (IE) and barriers that help mitigate the consequences of such IE, so that can appreciate the applicability of this method to industrial radiography services, to reduce the risk to acceptable levels. The fundamental advantage associated with the application of this methodology is that can be applied by the professionals working in the service and identifies specific weaknesses that from the point of view of safety there, so they can be prioritized resources depending on risk reduction. (Author)

  4. Radiological incidents in industrial gamma radiography in the Philippines, 1979-1993

    International Nuclear Information System (INIS)

    Borras, A.M.

    1994-01-01

    Among the many practices of radiation sources, the practice of industrial gamma radiography in the country has the most number of reported radiological incidents. During the past fourteen (14) years, from 1979-1993, twenty (20) incidents that have occurred were reported to the Institute. This paper presents the nature and extent of the 20 reported incidents as well as the results of the analysis of why these incidents happened. The results of the analysis showed that the causes of these incidents are mainly human error and equipment failure. Hence, the factors that can minimize or prevent the chance of occurrence and/or recurrence of incidents and in minimizing the hazard in case of radiological incidents are: a) proper training and re-training of personnel; b) proper and regular inspection and maintenance of equipment; c) adequate radiation survey; and d) proper storage and inventory of the radiography sealed sources. (author). 3 refs.; 5 figs.; 1 tab

  5. Industrial radiography. Gamma radiography

    International Nuclear Information System (INIS)

    Menetrier, J.

    1975-01-01

    Informations are given on gamma radiodefectology regulations, entire references and main dispositions applicable to each state of the European Economic Community. The content includes previous arrangements for source acquisition, holding and use of the sources, transport, accidents, civil liability of the source holder, person insurance against radiation hazards and contamination, property insurance, penal liability of the source holder

  6. Advances in digital industrial radiology - New application areas beyond film radiography

    Science.gov (United States)

    Ewert, Uwe

    2013-01-01

    Similar to the success story of digital photography a major upheaval has been observed in digital industrial radiology. Digital Detector Arrays enable the increase of contrast sensitivity up to a factor of 10 in comparison to film radiography. Computed radiography with phosphor imaging plates substitutes film applications. The increased sensitivity of digital detectors enables the efficient usage for dimensional measurements and functionality tests substituting manual maintenance. The measurement of wall thickness and corrosion status is state of the art in petrochemical industry. X-ray back scatter techniques have been applied in safety and security relevant applications with single sided access of source and detector. Computed tomography (CT) applications cover the range from m to nm scale. The scope of CT applications changes from flaw detection to dimensional measurement in industry. Mobile computed tomography is applied for in-service radiographic crack detection and sizing in welded pipes in nuclear power industry and aerospace applications. CT has been applied for evaluation of hot cracking susceptibility of modern weld alloys. In combination with modified varestraint transvarestraint tests (MVT) the cumulative crack length as function of stress and depth was determined. This enables the quantitative characterization of the weldability properties of different materials.

  7. Implementation of the safety assessment in the practice of industrial radiography

    International Nuclear Information System (INIS)

    Alfonso Pallarés, C.; Pérez Reyes, Y.

    2015-01-01

    The CNSN as regulatory authority has regulatory control processes based on regulations, permits, inspections and limitation to ensure the supervision and control of the practice of industrial radiography. On the other hand in the light of the new regulations approved and being implemented such as: Resolution 334/2011 CITMA 'Regulation on Notification and authorization of practices and activities associated with the use of ionizing radiation sources' and Resolution 17 / 2012, Security Guide: Security Assessment Practices and Activities associated with the use of ionizing radiation (recommendatory), it is necessary for compliance with regulatory requirements concerning the safety assessment. Since 2009 it has been applied this experience in different medical practices and industry, providing a systematic and consistent basis, to the safety assessment of all facilities and activities, which has helped increase the confidence that has been achieved an adequate level of security. The work was able to identify that there is a group of barriers operating in the risk reduction in various accident sequences and therefore have a relative importance in risk reduction, recommendations in this regard to improve the program management of safety in the practice of industrial radiography. [es

  8. SisRadiologia: a new software tool for analysis of radiological accidents and incidents in industrial radiography

    International Nuclear Information System (INIS)

    Lima, Camila M. Araujo; Silva, Francisco C.A. da; Araujo, Rilton A.

    2013-01-01

    According to the International Atomic Energy Agency (IAEA), many efforts have been made by Member states, aiming a better control of radioactive sources. Accidents mostly happened in practices named as high radiological risk and classified by IAEA in categories 1 and 2, being highlighted those related to radiotherapy, large irradiators and industrial radiography. Worldwide, more than 40 radiological accidents have been recorded in the industrial radiography. Worldwide, more than 40 radiological accidents have been recorded in the industrial radiography area, involving 37 workers, 110 members of the public and 12 fatalities. Records display 5 severe radiological accidents in industrial radiography activities in Brazil, in which 7 workers and 19 members of the public were involved. Such events led to hands and fingers radiodermatitis, but to no death occurrence. The purpose of this study is to present a computational program that allows the data acquisition and recording in the company, in such a way to ease a further detailed analysis of radiological event, besides providing the learning cornerstones aiming the avoidance of future occurrences. After one year of the 'Industrial SisRadiologia' computational program application - and mostly based upon the workshop about Analysis and Dose Calculation of Radiological Accidents in Industrial Radiography (Workshop sobre Analise e Calculo de dose de acidentes Radiologicos em Radiografia Industrial - IRD 2012), in which several Radiation Protection officers took part - it can be concluded that the computational program is a powerful tool to data acquisition, as well as, to accidents and incidents events recording and surveying in Industrial Radiography. The program proved to be efficient in the report elaboration to the Brazilian Regulatory Authority, and very useful in workers training to fix the lessons learned from radiological events.

  9. The 10 recommendations for prevention of radiation accidents in industrial gamma radiography; As 10 recomendacoes mais importantes para prevencao de acidentes radiologicos em gamagrafia industrial

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luana Silva de

    2015-07-01

    The Industrial Gamma Radiography, as part of Industrial Radiography, stands out as the most widespread and plays an important role in the quality control of different materials and devices. However, IAEA classifies industrial gamma radiography in the Category 2 as very dangerous due to the radiological risk caused by the use of high activity radioactive sources. In March, 2012, a Brazilian Workshop on Prevention of Industrial Gamma Radiography Accident was performed by DIAPI/CNEN with the objective of disseminating knowledge about radiological accidents with radioactive sources in this application. During this Workshop, IRD/CNEN conducted a survey with 75 participants using a form with 22 recommendations to prevent radiological accidents, aiming to select the most voted. This present work aims to perform a detailed statistical study to define the Top 10 Recommendations for industrial gamma radiography operator avoids radiological accidents and to prepare a brochure with these top 10 recommendations to be distributed to all industrial gamma radiography radiation workers. Data analysis was performed using the statistical method 'Frequency Distribution', among the 75 participants categorized as General, RPO, and Other Workers of the area. The results were obtained for each category, accounting for the total of 22 recommendations in its percentage and number of votes, and the top 10 recommendations were defined to prevent radiological accidents. The first place and most important recommendation is 'Always use a personal alarm monitor throughout the work'. One of the conclusions is that the brochure with the Top 10 Recommendations shows to be understandable and useful for dissemination and training of radiation workers to avoid radiological accidents in industrial gamma radiography. (author)

  10. A preliminary design of mechanical device on industrial digital radiography equipment design

    International Nuclear Information System (INIS)

    Nur Khasan; Samuel Praptoyo

    2015-01-01

    A preliminary design of mechanical device on industrial digital radiography equipment has been done. this design is intended as a basis for the manufacture of complete facilities for the realization a prototype on industrial digital radiography equipment. the design and construction were carried out by paying attention to the general configuration of the basic design in which its mechanical design has several components with specific dimensions and heavy mass. this design consist of a main frame holder, flat panel detector support and hydraulic hand stacker for mounting the x-ray machine. this mechanical device design will then be fabricated to facilitate and assist work of digital radiographic retrieval. computer application programs sketch-up is used to draw this design and the analysis stress of autodesk inventor to analysis the strength construction design. the results of this design are the configuration drawing, sketch drawings of construction and the safety factor of construction design with a minimum value of 2.39 as well as a maximum value of 15 when to be simulated by the load 500 Kg which is 4 times of total workload. (author)

  11. Promoting the safety performance of industrial radiography using a quantitative assessment system.

    Science.gov (United States)

    Kardan, M R; Mianji, F A; Rastkhah, N; Babakhani, A; Azad, S Borhan

    2006-12-01

    The increasing number of industrial radiographers and their considerable occupational exposure has been one of the main concerns of the Iran Nuclear Regulatory Authority (INRA) in recent years. In 2002, a quantitative system of evaluating the safety performance of licensees and a complementary enforcement system was introduced by the National Radiation Protection Department (NRPD). Each parameter of the practice is given a weighting factor according to its importance to safety. Assessment of the licensees is done quantitatively by summing up their scores using prepared tables. Implementing this system of evaluation showed a considerable decrease in deficiencies in the various centres. Tables are updated regularly as a result of findings during the inspections. This system is used in addition to enforcement to promote safety performance and to increase the culture of safety in industrial radiography.

  12. Use of cost benefit analysis in the field of industrial radiography

    International Nuclear Information System (INIS)

    Croft, J.R.; Webb, G.A.M.; Tattersall, P.; Sutherland, A.; Spence, E.

    1988-01-01

    Over the past decade NRPB has had a program of work on the development of cost benefit analysis (CBA) techniques in the optimisation of radiological protection. A provisional framework for including suggestions for assigning a value to unit collective dose was published for consultation in 1981/82 and after various interim statements this process culminated in formal advice in 1986. As part of this work, and as part of a project for the Commission of the European Communities (CEC) the NRPB has carried out a number of case studies to demonstrate the practical implementation of ALARA or optimisation of protection using CBA. These techniques, used in conjunction with ALARA audits, are now in general use in the NRPB's Radiation Protection Advisor Service. They have been used for a variety of medical and industrial situations, but mainly in industrial radiography as this is the part of the non-nuclear sector where occupational exposure problems predominate. Three cases are presented as representative examples

  13. Industrial Assessment Center Program Impact Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Martin, M.A.

    2000-01-26

    This report presents the results of an evaluation of the U.S. Department of Energy's Industrial Assessment Center (IAC) Program. The purpose of this program is to conduct energy, waste, and productivity assessments for small to medium-sized industrial firms. Assessments are conducted by 30 university-based industrial assessment centers. The purpose of this project was to evaluate energy and cost savings attributable to the assessments, the trained alumni, and the Websites sponsored by this program. How IAC assessments, alumni, and Web-based information may influence industrial energy efficiency decision making was also studied. It is concluded that appreciable energy and cost savings may be attributed to the IAC Program and that the IAC Program has resulted in more active and improved energy-efficiency decision making by industrial firms.

  14. Assessment of the main deviations found during regulatory inspections in industrial gamma radiography in Argentina

    International Nuclear Information System (INIS)

    Alonso Jimenez, Maria T.; Ermacora, Marcela

    2008-01-01

    The present paper shows the regulatory work made through inspections concerning radiation safety and security in the area of industrial gamma radiography. An account is shown of the items which should be available in the storage facility where the equipment and radioactive sources are placed as well as in site radiography and which are required to the users of the equipment meant for this practice, in order to ensure compliance with the regulations in force. The objective of this paper is to assess the most frequent deviations to the regulatory standards found during this type of inspections, such as lack of complete and operable radiation protection equipment, lack of available elements bound to act in case of emergency, no delimitation of controlled areas, gamma radiography equipment stored in unlocked position, wear gauge unavailable, record of movements of equipment and radioactive sources not updated, anomalous monthly or annual personal dose values, among the main findings. In particular, in connection with dose reports, some cases of occupational exposed workers exceeding the annual dose limits or investigation levels are highlighted. In addition, the explanations provided by the person responsible for radiation protection of companies in regard to the possible causes or circumstances which might have given rise to such dose values, the conclusions reached and the preventive and corrective measures implemented by these companies are analysed. Finally, an assessment of the annual dose distributions of the occupational exposed workers concerned with this kind of practice in the period 2004-2007 is shown. As a conclusion, the relevance of these deviations according to degradation in safety and security performance and the role of the regulatory work as a promoter of the implementation of safety culture will be emphasized. (author)

  15. Quality assurance procedure for functional performance of industrial gamma radiography exposure devices

    International Nuclear Information System (INIS)

    Kannan, R.; Yadav, R.K.; Rajoo Kumar; Bhatt, B.C.; Sivaraman, G.; Nandkumar, A.N.

    2003-05-01

    An Industrial Gamma Radiography Exposure Device (IGRED) consists of various moving parts and accessories and wear and tear take place often. This may increase the possibility of radiation incidents and result in avoidable radiation exposure. Quality assurance tests of the equipment for functional performance plays a major role in ensuring that the exposure device and its accessories perform their intended functions and satisfy radiation safety requirements to avert potential exposures to operators. Therefore, in India it is practiced as mandatory requirement that each IGRED is tested for its functional performance and only after ascertaining that features of operational safety are satisfactory, loading of the source into the radiography exposure device can be permitted. This procedure which is being. practiced since the late 1970s, has contributed significantly towards the safe use of IGREDs and minimising the occurrence of radiation accidents. The purpose of this document is to highlight the importance of periodic functional performance check of each IGRED as per the checklist for the testing procedures. It is also proposed to entrust this activity to accredited laboratories, which have the necessary infrastructure to carry out this activity. The prerequisites for accreditation of such laboratories to carry out this activity and the testing procedures to be adopted for checking the functional performance of various models of IGREDs used in this country are given in this report. (author)

  16. neutron radiography

    International Nuclear Information System (INIS)

    Barton, J.P.

    1993-01-01

    Neutron radiography (or radiology) is a diverse filed that uses neutrons of various energies, subthermal, thermal, epithermal or fast in either steady state or pulsed mode to examine objects for industrial, medical, or other purposes, both microscopic and macroscopic. The applications include engineering design, biological studies, nondestructive inspection and materials evaluation. In the past decade, over 100 different centers in some 30 countries have published reports of pioneering activities using reactors, accelerators and isotopic neutron sources. While film transparency and electronic video are most common imaging methods for static or in motion objects respectively, there are other important data gathering techniques, including track etch, digital gauging and computed tomography. A survey of the world-wide progress shows the field to be gaining steadily in its diversity, its sophistication and its importance. (author)

  17. Radiological emergency system in Madagascar, case of loss of a source of industrial radiography

    International Nuclear Information System (INIS)

    Randriantsizafy, R.D.; Raoelina Andriambololona; Zafimanjato, J.L.R.

    2012-06-01

    In Madagascar, a national radiological emergency response is not formally established. However, an Ad Hoc Committee of safety and nuclear safety and radiological is in place. The committee is composed of several Government entities and the role of each is identified. This Ad Hoc Committee has demonstrated its effectiveness for real action in 2010 with the loss of industrial radiography Container with Ir-192 source, the emergency is classified in threat category IV. Concerning the theft, the communication with the public and the other state entities, the search for the source and the source recovery were conducted in coordination between the different members. And of course, the lessons were reported during the operation which lasted more than three months

  18. Planning the recovery of an industrial radiography source which fails to return to its storage container

    Energy Technology Data Exchange (ETDEWEB)

    Hockings, C. [Qantas Airways, Sydney, NSW (Australia)

    1998-11-01

    Effective planning is fundamental to the safe use of radioactive materials. Such planning must include the safe recovery of the radioactive material in the event of an accident. This discussion is restricted to the application of radioactive material for industrial radiography using conventional source projectors and containers. Site operators of such equipment are required by New South Wales law to be trained to a minimum standard and licensed. However the infrequency of practicing recovery procedures or the absence of a recovery plan entirely, provides scope for inappropriate responses by an operator in an accident situation. The plan described here uses a flow chart approach to guide the operator through the decision required at such a time. A review of earlier accidents is also included

  19. Evaluation of the Radiological Safety of 192 Ir Apparatus for Industrial Gamma Radiography

    International Nuclear Information System (INIS)

    Aquino, J. O.; Silva, F. C. A. da; Ramalho, A. T.; Godoy, J. M. O.

    2004-01-01

    The majority of the 192Ir apparatus for industrial gamma radiography have been in usage in Brazil for more than 20 years. They are portable, and almost all operate according to category II. The main objective of this work was to assess the radiological safety of the 11 models of 192Ir apparatus most used in Brazil. The 11 models of 192Ir apparatus were studied with respect to compliance with the main safety requirements of three editions of international Standards ISO 3999. Six models were already manufactured incorporating the safety devices specified in the first edition of ISO 3999, issued in 1977. However, five models were not. The validity of their type B certificates for transport packages was also evaluated. (Author) 8 refs

  20. A Glance on the Safety Culture in Industrial Gamma Radiography in the Philippines: Regulatory Body Perspective

    International Nuclear Information System (INIS)

    Borras, A.M.

    2016-01-01

    The current version of the Code of PNRI Regulations (CPR) Part 11 was published in the Official Gazette on 2010. It is just a year ahead of the publication of the IAEA Specific Safety Guide No. 11. In view of these, radiation safety culture in the practice of industrial gamma radiography was not yet fully introduced in the said national regulations in the country. However, it should not be a reflection that the radiation workers in the country specifically in the said field of practice do not exercise positive safety culture. The Nuclear Regulatory Division (NRD)—regulatory arm, although not yet separated from the Philippine Nuclear Research Institute (PNRI0) as mandated by law — the promotional organization, has a well established and systemic regulatory infrastructure. It is attested by several studies and reports, among others. This study aims to assess the status of the existing safety culture in the conduct of industrial gamma radiography in the country through personnel perception survey of the radiation workers, i.e., managers, radiation safety officers, radiographers and radiographer’s assistants, based on the IAEA five characteristics of safety culture stipulated in the IAEA Safety Guide No. GS-G-3.5, “The Management System for Nuclear Installations”. It is assessed by the NRD of the PNRI. Also, the study determines the existence of safety culture as to the perspective of NRD through observations on the conduct of radiographic operations and walk-through of the facility while using the three-level Schein Model, i.e., “artefacts”, “espoused values” and “basic assumptions” and document reviews, among others

  1. Assessment of whole-body occupational radiation exposure in industrial radiography practices in Bangladesh during 2010-2014

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, M.S.; Hoque, A.; Khan, R.K.; Siraz, M.M.M., E-mail: msrahman74@hotmail.com [Health Physics Division, Atomic Energy Centre, Shahbag, Dhaka (Bangladesh); Begum, A. [Physical Science Division, Bangladesh Atomic Energy Commission, Dhaka (Bangladesh)

    2016-07-01

    Presently, ten industrial radiography facilities are operating in Bangladesh using X-ray or gamma-ray sources. During the last 5-year, 14 industrial radiography facilities were received individual monitoring service using thermoluminescent dosimeters (TLDs) from the Health Physics Division (HPD), Atomic Energy Centre, Dhaka under Bangladesh Atomic Energy Commission. HPD is the only individual monitoring service provider in Bangladesh due to external sources of ionizing radiation. The number of monitored industrial radiography facilities ranged from 7 to 14 while the number of worker ranged from 72 to 133 during the study period. The annual average effective doses received from external radiation in industrial radiography workers and the distributions of the annual effective doses by dose intervals are presented. The distribution of the occupational doses shows that the majority (about 75 %) of workers received doses below 1 mSv for the last 5-years. Even though, very few workers (about 1%) received doses higher than average annual dose limit (20 mSv), but no workers received doses higher than 100 mSv in 5 consecutive years. The average annual effective dose of industrial radiography workers in Bangladesh is higher than the corresponding values in Tanzania, Greece, Poland, Australia, UK and lower than in Bosnia and Herzegovina, USA and Canada. However, the average annual effective dose is comparable to the corresponding values in China, Brazil, Germany and India. The status and trends in occupational doses show that radiation protection situation at the majority of the workplace were satisfactory. In spite of that, additional measures are required due to big differences observed in the maximum individual doses over the last 5-year. (author)

  2. Dose estimation in the crystalline lens of industrial radiography personnel using Monte Carlo Method

    International Nuclear Information System (INIS)

    Lima, Alexandre Roza de

    2014-01-01

    The International Commission on Radiological Protection, ICRP, in its publication 103, reviewed recent epidemiological evidence and indicated that, for the eye lens, the absorbed dose threshold for induction of late detriment is around 0.5 Gy. On this basis, on April 21, 2011, the ICRP recommended changes to the occupational dose limit in planned exposure situations, reducing the eye lens equivalent dose limit from 150 mSv to 20 mSv per year, on average, during the period of 5 years, with exposure not to exceed 50 mSv in a single year. This paper presents the dose estimation to eye lens, H p (10), effective dose and doses to important organs in the body, received by industrial gamma radiography workers, during planned or accidental exposure situations. The computer program Visual Monte Carlo was used and two relevant scenarios were postulated. The first is a planned exposure situation scenario where the operator is directly exposed to radiation during the operation. 12 radiographic exposures per day for 250 days per year, which leads to an exposure of 36,000 seconds or 10 hours per year were considered. The simulation was carried out using the following parameters: a 192 Ir source with 1.0 TBq of activity, the source/operator distance varying from 5 m to 10 m at three different heights of 0.2 m, 1.0 m and 2.0 m. The eyes lens doses were estimated as being between 16.9 mSv/year and 66.9 mSv/year and for H p (10) the doses were between 17.7 mSv/year and 74.2 mSv/year. For the accidental exposure situation scenario, the same radionuclide and activity were used, but in this case the doses were calculated with and without a collimator. The heights above ground considered were 1.0 m, 1.5 m e 2.0 m, the source/operator distance was 40 cm and, the exposure time 74 seconds. The eyes lens doses, for 1.5 m, were 12.3 mGy and 0.28 mGy without and with a collimator, respectively. Three conclusions resulted from this work. The first was that the estimated doses show that the new

  3. The industrial radiography service in Brazil concerning to the radiation protection aspect

    International Nuclear Information System (INIS)

    Martins, M.M.

    1994-01-01

    A study about the industrial radiography situation in Brazil, concerning to the radiation protection aspects is shown. With this purpose it was made an inventory, with utilization of the file of facilities officially registered in industrial application from Brazilian Nuclear Energy Commission (CNEN). It was evaluated the quantity of accelerators), radiation monitors and radiation workers (health physics, operator). As quality and performance indicators of radiation protection the mean doses and the collective doses were used, and their variation from 1987 to 1990. As deficiency signals of radiological protection programs and procedures were utilized the 175 abnormal event occurred (radiological accident and emergency situation) from 1976 to 1992, after an analysis of their causes. The results showed that, for around 2000 monitored workers, the mean dose equivalent was between 0.83 to 2.70 mSv, and the collective dose, between 1.54 and 6.18 Sv.man, from 1987 to 1990. In this period, it was verified a tendency for reduction of means dose and collective dose values. It indicates a possible improvement of radiation protection services or an influence of economical situation of the country. From 175 abnormal events analysed, 456 persons were exposed, with 7.2% of them receiving doses above 50 mSv. These results were compared with those from others countries, such as United Kingdom and united States. (author). 76 refs, 16 figs, 24 tabs

  4. Lesson learned from two radiological incidents in industrial radiography in Iran

    International Nuclear Information System (INIS)

    Samimi, Bijan; Deevband Mohammad, Reza; Kardan Mohammad, Reza; Eshraghi, Ahmad

    2006-01-01

    This paper discussed two incidents occurred in Iran, follow-up investigations as well as lessons learned. Two Industrial Gamma Radiography Projectors (I.G.R.P.) included Ir-192 source with activities 24 and 30 Curies respectively were stolen. One of them was stolen in an industrial area with high security provision and the other one has been stolen at the home town without any security provision. The lessons learned from these incidents are discussed and the results are proposed as recommendations. Investigations show that the reasons for these incidents are as follows: 1. Insufficient training programs for radiographers. 2. Lack of specific emergency procedure for this type of incident in the company. 3. Not efficient National Emergency Plan for this type of threat. 4. Lack of technical and administrative measures to separate radioactive sources from unauthorized persons. 5. Lack of security plan in the company. 6. Insufficient supervision of Radiation Protection Officer (R.P.O.) or responsible person at the site. (authors)

  5. Progress in digital radiography

    International Nuclear Information System (INIS)

    Cappelle, A.

    2016-01-01

    Because of its practical aspect digital radiography is more and more used in the industrial sector. There are 2 kinds of digital radiography. First, the 'computed radiography' that uses a photon-stimulated screen, and after radiation exposure this screen must be read by an analyser to get a digit image. The second type is the 'direct radiography' that allows one to get a digit radiograph of the object directly. Digital radiography uses the same radioactive nuclides as radiography with silver films: cobalt, iridium or selenium. The spatial resolution of digital radiography is less good than with classical silver film radiography but digital radiography offers a better visual contrast. (A.C.)

  6. Evaluation of radiological safety conditions of panoramic portable irradiators of industrial radiography used in Brazil

    International Nuclear Information System (INIS)

    Aquino, Josilto Oliveira de

    2003-08-01

    In Brazil, the applications of ionizing radiation in industrial area are performed in about 900 installations, in which around 3000 radioactive sources are handled. Industrial radiography represents 14 % of this total, with 217 X rays equipment and 287 gamma radiography apparatus, according to a survey conducted in the present work. From these gamma apparatus, 90 % employ 192 Ir sources, followed by 60 Co and 75 Se, with 5 % each. The great majority of the 192 Ir apparatus have been in continuous usage in Brazil for more than 20 years, which means that they are old equipment. The totality of the 11 models of 192 Ir apparatus used in Brazil is imported from abroad. Those apparatus are portable, and almost all operate according to category II, i.e., the source assembly is mechanically projected out of the container. This last characteristic, besides the fact that the apparatus are already old-fashioned and worn-out, raises concerns about their radiological safety. The main objective of this work was to develop a specific methodology for inspection, testing and assessment of the radiological safety devices and state of maintenance of the 192 Ir apparatus. The idea is to prevent accidents, as physical failures can lead to overexposure of working staffs. In order to accomplish this, almost a hundred 192 Ir apparatus, from the 11 models used in Brazil, were studied. According to our results, almost 20 % of the 97 apparatus evaluated presented some kind of unsafe condition for proper operation, like poor state of maintenance and faults at the lock that retains the source at the secure position. From the 11 imported models of 192 Ir apparatus in use in Brazil, six models were already manufactured incorporating the safety devices specified by the first edition of the Standard ISO 3999, edited in 1977. However, five models do not comply even with this first edition of the Standard ISO 3999. Thus, they lack some important and basic safety devices. None of the 11 models comply

  7. Defect detection in industrial radiography: a multi-scale approach; Detection de defauts en radiographie industrielle: approches multiechelles

    Energy Technology Data Exchange (ETDEWEB)

    Lefevre, M.

    1995-10-01

    Radiography is used by Electricite de France for pipe inspection in nuclear power plant in order to detect defects. For several years, the RD Division of EDF has undertaken research to define image processing methods well adapted to radiographic images. The main issues raised by these images are their low contrast, their high level of noise, the presence of a trend and the variable size of the defects. A data base of digitized radiographs of pipes has been gathered and the statistical, topological and geometrical properties of all of these images have been analyzed. From this study, a global indicator of the presence of defects and local features, leading to a classification of images into areas with or without defects, have been extracted. The defect localisation problem has been considered in a multi-scale framework based on the creation of a family of images with increasing regularity and defined as a solution of a partial differential equation. From a choice of axioms, a set of equations may be deduced which define various multi-scale analyses. The survey of the properties of such analysed, when applied to images altered with different types of noise, has lead to the selection of the digitized radiographs best adapted multi-scale analysis. The segmentation process, uses the geodesic information attached to defects via connection cost concept. The final decision is based on a summary of the information extracted at several scales. A fuzzy logic approach has been proposed to solve this part. We then developed methods and tools for expertise guidance and validated them on a complete data base of images. Some global indicators have been extracted and a detection and localisation process has been achieved for large defects. (author). 117 refs., 73 figs.

  8. An assessment of the radiological impact of the operation of selected industrial gamma radiography facilities in Metro Manila

    International Nuclear Information System (INIS)

    Loterina, Roel A.; Espiritu, Raquel T.; Palattao, Ma. Visitacion B.

    1998-01-01

    Observations and radiation monitoring were done during radiographic operations conducted by eleven (11) industrial radiography institutions in 8 installations and in 4 project sites in Metro Manila, Batangas, and Antipolo. Radiological hazards involved during routine normal operations were evaluated in terms of potential doses to radiography workers and members of the public. Based on radiation monitoring results, radiography workers involved in routine and normal operations got whole body dose exposures ranging from 0.03 to 27.96 mSv/year. These are doses lower than the 50 mSv annual limit for radiation workers. Radiological consequences to radiography workers during abnormal occurrences and accident conditions were projected to be from as low as 0.03 mSv to as high as 7,500 mSv or 150 times the annual limit. Dose exposures of members of the public involved or affected were estimated to be from 0.08 mSv to doses easily exceeding the annual limit of 5 mSv. The upper limit of these doses greatly exceeds the half-lethal dose value of 4.5 Gy. This study recommends some measures to ensure safety of operating personnel from undue exposure to radiation during routine normal operations as well as during abnormal occurrences and accident conditions. (Author)

  9. Neutron radiography, techniques and applications

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1987-10-01

    After describing the principles of the ''in pool'' and ''dry'' installations, techniques used in neutron radiography are reviewed. Use of converter foils with silver halide films for the direct and transfer methods is described. Advantages of the use of nitrocellulose film for radiographying radioactive objects are discussed. Dynamic imaging is shortly reviewed. Standardization in the field of neutron radiography (ASTM and Euratom Neutron Radiography Working Group) is described. The paper reviews main fields of use of neutron radiography. Possibilities of use of neutron radiography at research reactors in various scientific, industrial and other fields are mentioned. Examples are given of application of neutron radiography in industry and the nuclear field. (author)

  10. Industrial assessment center program. Final Report

    International Nuclear Information System (INIS)

    Ahmad R. Ganji, Ph.D., P.E., IAC DIrector

    2007-01-01

    The Industrial Assessment Center (IAC) at San Francisco State University (SFSU) has served the cause of energy efficiency as a whole, and in particular for small and medium-sized manufacturing facilities in northern and central California, within a approximately 150 miles (radial) of San Francisco since 1992. In the current reporting period (September 1, 2002 through November 31, 2006) we have had major accomplishments, which include but are not limited to: Performing a total of 94 energy efficiency and waste minimization audit days of 87 industrial plants; Recommending and analysis of 809 energy efficiency measures; Training 22 energy engineers, most of whom have joined energy services companies in California; Disseminating energy efficiency information among local manufacturers; Acting as an information source for energy efficiency for local manufacturers and utilizes; Cooperating with local utilities and California Energy Commission in their energy efficiency projects; Performing various assignments by DOE such as dissemination of information on SEN initiative, conducting workshops on energy efficiency issues, contacting large energy user plants--Establishing a course on 'Energy: Resources, Alternatives and Conservation' as a general education course at SFSU; Bringing energy issues to the attention of students in classrooms

  11. Preparation and realization of industrial radiography for the non destructive testing of welds in Nuclear Power Plants: A spatial cognition analysis

    International Nuclear Information System (INIS)

    Lafon, M.; Tonnoir, S.; Thibault, G.; Lafon, M.; Berthoz, A.

    2008-01-01

    Controls of welds by radiographies are an efficient non destructive technique but it can be dangerous if not managed following a strict set of rules. EDF acts to avoid risks via several ways (adapted tools, best practices) and seeks for an integration of the radiographies with respect to the other maintenance operations, in order to raise the ratio of availability of the electricity production unit. This study explores an original analysis of industrial radiography: the influence of the representations of the workplace and its utilizations. This document supports the utilization of some space constraints as explanations of difficulties in the industrial radiography activity. The document proposes innovative points of view coming for on-site observations and from a theoretical background 'cognitive sciences' completed by technical propositions. (author)

  12. Atomic Energy Control Regulations: interpretation of revisions relating to industrial radiography

    International Nuclear Information System (INIS)

    1983-09-01

    The purpose of this document is to provide assistance to those affected by section 18 to 18.23 of the Canadian Atomic Energy Control Regulations. Words, phrases, and concepts that are specific to these Regulations are explained herein. However, the corresponding sections of the Regulations should be examined to obtain the exact wording. Although sections 18 to 18.23 of the Canadian Atomic Energy Control Regulations apply to both neutron and gamma radiography, this guide has been written for only the latter. Persons engaged in neutron radiography should consult the Atomic Energy Control Board (AECB)

  13. Application of (n, f)-radiography for assessment of environmental impact by uranium due to industrial activity

    International Nuclear Information System (INIS)

    Bertman, E.B.; Vasidov, A.; Tsipin, V.Z.; Tillaev, T.S.

    2001-01-01

    Neutron induced (n, f)-radiography has been used for assessment of radioactive impact on biota by industrial wastes and exhalation. The objects analyzed were tree leaves which can serve the natural seasonal microelements collectors. Sampling was made in the urban area with two main industrial plants - on the processing of atomic raw material and production of mineral fertilizer. The samples were analyzed by neutron activation analysis (NAA) and neutron induced (n, f)-radiography. The latter technique was used for the study of uranium distribution in a leaf surface. A procedure of the technique was that a detector foil (LEXAN) in a tied contact with a sample surface was subject to thermal neutron exposure in our WWR-SM nuclear reactor. Fission fragments from the 235U(n, f) reaction form radiation damages - tracks - in the surface layer of the detector. Due to close contact of the detector to the sample surface, location of tracks is consistent to location of the determined element. This makes it possible to get a picture of surface distribution of the element and, thus, to get an idea on genesis of pollution with this element. There are two principal ways for intake of pollutant elements in plants, namely, through the root system from the soil, and through the aerosol, dust and/or rain deposition on leaves. Presence of dense track spots like clusters or stars in the produced radiographs asserts their genesis was due to industrial disposal and exhalation. The average uranium concentrations in the leaves cover the range of 0.026 to 0.83 ppm. Based on the experimental data, uranium mapping of the explored territory has been made. Epicenter of the highest uranium level field was spatially consistent to location of the industrial plants, and, therefore, most probably, was generated by their activity

  14. 14 CFR 1201.402 - NASA Industrial Applications Centers.

    Science.gov (United States)

    2010-01-01

    ..., Department of Computer Science, Baton Rouge, LA 70813-2065. (b) To obtain access to NASA-developed computer... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false NASA Industrial Applications Centers. 1201... ORGANIZATION AND GENERAL INFORMATION General Information § 1201.402 NASA Industrial Applications Centers. (a...

  15. Performance evaluation of the conventional Brazilian industries radiation protection in the small industrial gauges and industrial radiography areas; Sistema de avaliacao de desempenho em radioprotecao das industrias convencionais brasileiras nas areas de medidores nucleares e radiografia industrial

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Joyra Amaral dos

    1999-08-01

    This works evaluates by punctuation the performance in conventional Brazilian industries radiation protection area which make use of small industrial gauges and industrial radiography. It proposes, procedures for industry self-evaluation, besides a new radiation protection plans pattern for the small industrial gauges area. The data source where inspection reports of Dosimetry Radiation Protection Institute/Nuclear Energy Commission conventional Brazilian industries' radiation protection plans, beyond visitation to the inspection place. The performance evaluation has been realized both in the administrative and operational aspects of the industries. About of 60% of the industries have a satisfactory register control which does not happen to the operational control. The performance evaluation advantage is that industries may self-evaluate, foreseeing Dosimetry Radiation Protection Institute's regulation inspections, correcting its irregularities, automatically improving its services. The number of industries which have obtained satisfactory performance in both areas is below 70%, both in administrative and operational aspects. Such number can be considered a low one as it is radiation protection. The procedures propose in this work aim to improve such a situation. (author)

  16. Reconstructive dosimetry and radiation doses evaluation of members of the public due to radiological accident in industrial radiography

    International Nuclear Information System (INIS)

    Lima, Camila Moreira Araujo de

    2016-01-01

    Radiological accidents have occurred mainly in the practices recognized as high risk radiological and classified by the IAEA as Categories 1 and 2, and highlighted the radiotherapy, industrial irradiators and industrial radiography. In Brazil, since there were five major cases in industrial radiography, which involved 7 radiation workers and 19 members of the public, causing localized radiation lesions on the hands and fingers. One of these accidents will be the focus of this work. In this accident, a 192 Ir radioactive source was exposed for more than 8 hours in the workplace inside a company, exposing radiation workers, individuals of the public and people from the surrounding facilities, including children of a school. The radioactive source was also handled by a security worker causing severe radiation injuries in the hand and fingers. In this paper, the most relevant and used techniques of reconstructive dosimetry internationally are presented. To estimate the radiation doses received by exposed individuals in various scenarios of radiological accident in focus, the following computer codes were used: Visual Monte Carlo Dose Calculation (VMC), Virtual Environment for Radiological and Nuclear Accidents Simulation (AVSAR) and RADPRO Calculator. Through these codes some radiation doses were estimated, such as, 33.90 Gy in security worker's finger, 4.47 mSv in children in the school and 55 to 160 mSv for workers in the company during the whole day work. It is intended that this work will contribute to the improvement of dose reconstruction methodology for radiological accidents, having then more realist radiation doses. (author)

  17. Gamma radiography and its technological application

    International Nuclear Information System (INIS)

    Courtois, G.

    1962-01-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  18. 75 FR 75867 - National Sheep Industry Improvement Center

    Science.gov (United States)

    2010-12-07

    ... Service 7 CFR Part 63 National Sheep Industry Improvement Center AGENCY: Agricultural Marketing Service, USDA. ACTION: Affirmation of interim rule as a final rule. SUMMARY: The Agricultural Marketing Service... information, Marketing agreements, Reporting and recordkeeping requirements. PART 63--NATIONAL SHEEP INDUSTRY...

  19. Reconstructive dosimetry of radiological accidents - study of a brazilian case of industrial gamma radiography; Dosimetria reconstrutiva de acidentes radiologicos - estudo de um caso brasileiro de gamagrafia industrial

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Francisco Cesar Augusto da; Hunt, John G.; Ramalho, Adriana [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Pinto, Livia M.F. Amalfi [ARCtest - Servicos Tecnicos de Inspecao e Manutencao Industrial Ltda., Paulinia, SP (Brazil)]. E-mail: protecao@arctest.com.br

    2002-07-01

    On May 2000, an industrial gamma radiography operator, during a maintenance work of a {sup 60}Co irradiator, has suffered a radiological accident with severe consequences to the left hand. The experts of the High Doses Analysis Group (GADE/IRD/CNEN) initiated the reconstructive dosimetry for the radiation dose estimation, in order to determine the real dose received by the operator, and to help the medical evaluation for prescribing the medical procedures for treatment of the involved victim. This paper presents the reconstructive dosimetry performed through the determination of the radiation doses of the operator, based on theoretical, experimental and computational methods. For the computer methods, a program for the calculation of external doses were used, based on the Monte Carlo method, and a human body simulator composed by voxels. The values of effective and equivalent doses are also presented which has caused severe lesions on the operator hand.

  20. Problems related to design and construction of industrial radiography exposure room - an experience

    International Nuclear Information System (INIS)

    Siti Madiha Muhammad Amir; Mohd Khairi Mohd Said; Abdul Nassir Ibrahim; Ab Razak Hamzah

    2009-01-01

    In Non-Destructive Testing (NDT), especially in radiography method, inspections of components are executed either on-site or in-house. For in-house inspections, work must be performed in a specially constructed exposure room. The design of the exposure room must be according to specific requirements described in various documents related to radiation safety. Stringent requirements specified for the exposure room is for the purpose of ensuring the safety of public and radiation workers. These requirements are never compromised. One of the AELB requirements that need to be complied is that the permissible dose limit anywhere outside the room must be less than 0.25 mR/hr. In designing and constructing the exposure room, many factors must be taken into account such as shielding thickness, density of shielding, thickness of lead door, the roof design of the exposure room and many more. This paper highlights problems encountered and the considerations taken to design and construct the exposure room so that the exposure room will comply with the permissible dose limit set by the regulatory body. (Author)

  1. Characterization of mono-ethylene-glycol based industrial polyurethanes samples by fast-neutron radiography and neutron tomography

    Science.gov (United States)

    Rogante, Massimo; Söllradl, Stefan

    2016-09-01

    A complicated structural organization of polyurethanes may have a strong influence on the materials functional properties. Under particular conditions such as mechanical and thermal loading and aging, it leads to the material degradation, even in fresh-prepared bulk polymers and especially if defects are present in the material. Unwanted bubbles can be observed, which form during the expansion of the mixture during its chemical reaction and remain present in the final product. These macro-, micro- and nano-bubbles influence the material's performance. In this work, neutron radiography and tomography have been adopted to characterize at a macro-scale level the bulk of commercially available polyurethane samples, obtained from dissimilar- mixture ratios with different densities and branching levels as well as from different zones of the production mould. The characterisation allowed an estimation of the different dense materials - as they are used, e.g., in soles of shoes - as well as the invisible defects like pores and cracks, responsible for the materials fracture by mechanical loading. The obtained information are expected to be useful for various industrial sectors such as automotive and footwear industry. It will be completed by applying SANS, which has already proved to characterize the microstructure of the bulk-polymer with respect to nano-pores, micro-cracks and their arrangement in the polymer matrix.

  2. Flash radiography

    International Nuclear Information System (INIS)

    Jamet, F.

    1986-01-01

    Flash radiography is a method for recording radiographic pictures of a non-transparent high-speed phenomenon. Such events occur in a variety of fields: Ballistics, dynamic high pressure physics, detonics, industry, and medical diagnostics. The phenomena observed by flash-radiography generally move at velocities between 100 m/s and 10000 m/s. The motion blur recorded on the picture is negligible only if the duration of the X-ray pulse (or the exposure time) falls in the range 10 -8 - 10 -7 s. With a medical or industrial radiographic device, the correct blackening of a film is obtained with a current of some milliamperes and a mean exposure time of 0.1 s. From this it is deduced that the value of the current passing through a flash X-ray tube must be approximately equal to 10 4 A. These values cannot be attained in conventional X-ray tubes with a heated cathode. The production of large currents is mainly achieved by vacuum discharges and field emission. Two applications of the technique are presented: flash radiographs of shock waves, and flash X-ray diffraction. (Auth.)

  3. Evaluation of X-Ray Protective Measurements in Intraoral Radiography Equipped Centers in Yazd

    Directory of Open Access Journals (Sweden)

    D.Goodarzi Pour

    2005-02-01

    Full Text Available Statement of Problem: A few decades have past from using radiographic technology as an accurate paraclinical method and always protective measurements is applicated against ionizing radiation. As dentalradiography is a routine procedure in dentistry the importance of protective strategies is clear.Propose: The aim of this descriptive study is to evaluate the protection principles in centers which haveintraoral radiographic devices in Yazd.Material and Methods: We have considered all three aspects of practitioner, environment and patientprotection using questionnaire and visiting those centers.Results: 33/7% of dental offices ,10 clinics ,3 institution and faculty of dentistry had intraoral radiographicequipments. Stablishment of protection principles for radiographer was favorable. 7.7% of centers had x-ray room with leaded walls, 23.1% had curtain , in 69/2% of centers radiographers stood in correct position anddistance while taking radiograph. Regarding to protection of environment, beams leakage control in 23.1% dental offices, 70% of clinics, all institution and faculty of dentistry have done.Conclusion: Non of the centers used rectangular localizator, thyroid shield, film holder and just some centers used leaded apron in specific circumstances. We have concluded that patient protection constitute less consideration. Generally lack of protective consideration is related to deficient knowledge of operators. Lackof information about protection equipments causes decrease of demanding of these tools and ultimately lack of these equipments in the market.

  4. Industrial radiography: new bases for a better practice. An experience in Provence Alpes Cote d'Azur; Radiographie industrielle: de nouvelles bases pour une meilleure pratique. Une experience en Provence Alpes Cote d'Azur

    Energy Technology Data Exchange (ETDEWEB)

    Anon

    2007-07-01

    Ten years after the implementation of a first plan on industrial radiography, having for effect the reduction by half of dosimetry values registered near the industrial radiographs, these professional stay among the workers the most exposed to ionizing radiations. A new step have been overcome. this new plan is the result of a broad consensus based on a shared report: the practice of industrial radiograph can lead still to significant radiation exposure in case: lack of planning or preparation on workings, inadequate collective protection equipment as show the inquiries made by the work inspection and radiation protection inspection. face to this reality of exposure conditions a whole of good practices has been defined again through the Charter 2007. (N.C.)

  5. A Compact 5 MeV S-Band Electron Linac Based X-Ray Source for Industrial Radiography

    CERN Document Server

    Auditore, Lucrezia; De Pasquale, Domenico; Emanuele, Umberto; Italiano, Antonio; Trifirò, Antonio; Trimarchi, Marina

    2005-01-01

    A compact and reliable X-ray source, based on a 5 MeV, 1 kW, S-band electron linac, has been set up at the Dipartimento di Fisica, Universit\\'a di Messina. This source, coupled with a GOS scintillator screen and a CCD camera, represents an innovative transportable system for industrial radiography and X-ray tomography. Optimization of the parameters influencing the e-gamma conversion and the X-ray beam characteristics have been studied by means of the MCNP-4C2 code. The converter choice is the result of the study of the e-gamma conversion performances for different materials and materials thicknesses. Also the converter position with respect to the linac exit window was studied. The chosen converter consists in a Ta-Cu target inserted close to the linac window. The Cu layer acts as a filter both on the electrons from the source and on the low energy X-rays. The X-ray beam angular profile was studied by means of GafChromic films with and without collimation. In the final source project, a collimation system pr...

  6. The industrial radiography service in Brazil concerning to the radiation protection aspect; O servico de radiografia industrial no Brasil sob o aspecto da protecao radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Martins, M.M.

    1994-12-31

    A study about the industrial radiography situation in Brazil, concerning to the radiation protection aspects is shown. With this purpose it was made an inventory, with utilization of the file of facilities officially registered in industrial application from Brazilian Nuclear Energy Commission (CNEN). It was evaluated the quantity of accelerators, radiation monitors and radiation workers (health physics, operator). As quality and performance indicators of radiation protection the mean doses and the collective doses were used, and their variation from 1987 to 1990. As deficiency signals of radiological protection programs and procedures were utilized the 175 abnormal event occurred (radiological accident and emergency situation) from 1976 to 1992, after an analysis of their causes. The results showed that, for around 2000 monitored workers, the mean dose equivalent was between 0.83 to 2.70 mSv, and the collective dose, between 1.54 and 6.18 Sv.man, from 1987 to 1990. In this period, it was verified a tendency for reduction of means dose and collective dose values. It indicates a possible improvement of radiation protection services or an influence of economical situation of the country. From 175 abnormal events analysed, 456 persons were exposed, with 7.2% of them receiving doses above 50 mSv. These results were compared with those from others countries, such as United Kingdom and united States. (author). 76 refs, 16 figs, 24 tabs.

  7. Electronic Commerce Resource Centers. An Industry--University Partnership.

    Science.gov (United States)

    Gulledge, Thomas R.; Sommer, Rainer; Tarimcilar, M. Murat

    1999-01-01

    Electronic Commerce Resource Centers focus on transferring emerging technologies to small businesses through university/industry partnerships. Successful implementation hinges on a strategic operating plan, creation of measurable value for customers, investment in customer-targeted training, and measurement of performance outputs. (SK)

  8. Centers for manufacturing technology: Industrial Advisory Committee Review

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    An advisory committee, composed of senior managers form industrial- sector companies and major manufacturing trade associations and representatives from appropriate educational institutions, meets semi-annually to review and advise the Oak Ridge Centers for Manufacturing Technology (ORCMT) on its economic security program. Individual papers have been indexed separately for the database.

  9. Final Technical Report for University of Michigan Industrial Assessment Center

    Energy Technology Data Exchange (ETDEWEB)

    Atreya, Arvind

    2007-04-17

    The UM Industrial Assessment Center assisted 119 primary metals, automotive parts, metal casting, chemicals, forest products, agricultural, and glass manufacturers in Michigan, Ohio and Indiana to become more productive and profitable by identifying and recommending specific measures to improve energy efficiency, reduce waste and increase productivity. This directly benefits the environment by saving a total of 309,194 MMBtu of energy resulting in reduction of 0.004 metric tons of carbon emissions. The $4,618,740 implemented cost savings generated also saves jobs that are evaporating from the manufacturing industries in the US. Most importantly, the UM Industrial Assessment Center provided extremely valuable energy education to forty one UM graduate and undergraduate students. The practical experience complements their classroom education. This also has a large multiplier effect because the students take the knowledge and training with them.

  10. Filmless Radiography

    Science.gov (United States)

    1997-01-01

    Technology initially prototyped under a Small Business Innovation Research contract between Quantex Corporation and Langley Research Center was licensed to Liberty Technology and incorporated into RADView, a new filmless radiography technology. The NASA-sponsored work involved the investigation of Electron Trapping, which led to a solid-state film that uses a special class of photoluminescent materials to capture radiographic images. RadView is a total imaging solution for the conversion of radiographic film records to digital format and digital acquisitions of radiographs. With the RADView technology, there is a reduction of exposure times and errors; film waste is eliminated; and the efficiency of data management and precise image analysis is boosted. The solid-state film can be exposed, read, erased, and re- exposed indefinitely until mechanical replacement is required. Digital images can be stored to optical media for up to 100 years and beyond without information loss.

  11. Experience in industrial radiography equipment into carry out inspections in Brazil

    International Nuclear Information System (INIS)

    Lopes, Valdir Maciel; Silva, Joao

    2008-01-01

    The Nuclear and Energy Research Institute (IPEN), in accordance with the attributions given by the National Commission of Nuclear Energy (CNEN), has been supplying the market with radioactive sealed sources of Iridium 192 ( 192 Ir), for Brazil and some South America Countries, for more than 24 years. In this period, the experience acquired in the accompanied of the technological improvement in the industrial gammagraphy equipment; into Sealed Sources Production Laboratory (LPFS) will be show. Of the set of operations carry out in the LPFS, since the assemblies, tests of qualification of the sources also inspection at of the equipment for posterior applications in field, it is intended to demonstrate to the technological improvement associate to the radiological and operational security. In this work, the data base of the system of the LPFS will be used, as well as the professional experience of the laboratory team in the daily relationship with the companies responsible for the equipment operation. (author)

  12. Risk assessment at workplaces in industrial radiography: from research to action

    Energy Technology Data Exchange (ETDEWEB)

    Coletti, F.; Paul, D.; Sari-Minodier, I.; Botta, A. [Universite de la Mediterranee, Lab. de Biogenotoxicologie et Mutagenese Environnementale (EA 1784 IFR PMSE 112), Faculte de Medecine, 13 - Marseille (France); Mocaer, S.; Sotty, Ph. [Direction Regionale du Travail de l' Emploi et de la Formation Professionnelle, PACA, 13 - Marseille (France); Grolleau, N. [Direction Departementale du Travail de l' Emploi et de la Formation Professionnelle, 13 - Marseille (France); Provens, H.; Landier, D. [Direction de la Surete Nucleaire et de la Radioprotection, div. de Marseille, 13 - Marseille (France); Soler, J.L. [Caisse Regionale d' Assurance Maladie Sud Est, 13 - Marseille (France)

    2006-07-01

    This study focuses on the use of gamma photons usually emitted by a source of iridium 192. Analysis of the working conditions for a radiographer considers first the preparation of the equipment at the home base, then the transport of the gamma projector, considered hazardous under legislation to the site; then the operation itself on the site with, several gamma-graphy shooting per night; and finally to return to base. A table has been produced in order to calculate the doses received during the different stages of the shooting of a a given activity: dose equivalent rate during transport by car: 1.5 {mu} Sv/h, dose equivalent during projector handling: 200 {mu}Sv/h, dose equivalent during collimator handling:15{mu}Sv/h, dose equivalent from change of position between projector and remote control: 10{sup -2}{mu}Sv/shooting, dose equivalent during source ejection: 4{mu}Sv/shooting, dose equivalent during source ejection behind a screen(1 cm of steel): 3{mu}Sv/shooting, dose equivalent at shelter point (behind screen): 5{mu}Sv/h. These calculations indicate that doses(exposure) which are often ignored, such as transport dose or collimator dose, are significant. Thus, working conditions need to be improved with regard to justification, optimization and limitation principles. All the work of the industrial radiographer must be evaluated according to a charter. The charter covers all aspects of operations. It begins with a review of basic radiation protection principles followed by the role and responsibilities of each stakeholder, personal training, medical and dosimetric monitoring of workers. Finally, the step by step procedure is described. (N.C.)

  13. Risk assessment at workplaces in industrial radiography: from research to action

    International Nuclear Information System (INIS)

    Coletti, F.; Paul, D.; Sari-Minodier, I.; Botta, A.; Mocaer, S.; Sotty, Ph.; Grolleau, N.; Provens, H.; Landier, D.; Soler, J.L.

    2006-01-01

    This study focuses on the use of gamma photons usually emitted by a source of iridium 192. Analysis of the working conditions for a radiographer considers first the preparation of the equipment at the home base, then the transport of the gamma projector, considered hazardous under legislation to the site; then the operation itself on the site with, several gamma-graphy shooting per night; and finally to return to base. A table has been produced in order to calculate the doses received during the different stages of the shooting of a a given activity: dose equivalent rate during transport by car: 1.5 μ Sv/h, dose equivalent during projector handling: 200 μSv/h, dose equivalent during collimator handling:15μSv/h, dose equivalent from change of position between projector and remote control: 10 -2 μSv/shooting, dose equivalent during source ejection: 4μSv/shooting, dose equivalent during source ejection behind a screen(1 cm of steel): 3μSv/shooting, dose equivalent at shelter point (behind screen): 5μSv/h. These calculations indicate that doses(exposure) which are often ignored, such as transport dose or collimator dose, are significant. Thus, working conditions need to be improved with regard to justification, optimization and limitation principles. All the work of the industrial radiographer must be evaluated according to a charter. The charter covers all aspects of operations. It begins with a review of basic radiation protection principles followed by the role and responsibilities of each stakeholder, personal training, medical and dosimetric monitoring of workers. Finally, the step by step procedure is described. (N.C.)

  14. Signal differential-to-noise ratio (SdNR) in the evaluation of radiography techniques for optimisation of the industrial computed radiography

    International Nuclear Information System (INIS)

    Saddock, Aline; Candeias, Janaina P.; Oliveira, Davi F.; Lopes, Ricardo T.

    2007-01-01

    The transition from analog to digital operation which the radiography has gone through, has provided new and important challenges in the way the images are acquired and displayed. There is several acquisition system of digital image, such as for example, the computerized system, which uses Image Plates (IP). This system was used in the accomplishment of this work with the aim to study a technique capable of optimizing the acquisition of digital image. A methodology for the evaluation of image quality is through the parameter signal differential-to- noise ratio (SdNR). However, in order to compare different radiographic techniques through this system it is also necessary to calculate the Figure of Merit (FOM) that in this in case, it is given by the square of the SdNR per unit of applied dose. The method proposed in this work is about the use of IP to carry out SdNR experimental measurements and consequently FOM measurements in applications of the x-ray of pieces in aluminum. This proceeding was performed varying some specific parameters of the system, as high voltage, exposition and the use of filters in the X-rays tube exit. As a result, an SdNR was obtained for each technique, allowing in this way, to verify the behavior of the FOM in each one of them. (author)

  15. Digital radiography

    International Nuclear Information System (INIS)

    Zani, M.L.

    2002-01-01

    X-ray radiography is a very common technique used to check the homogeneity of a material or the inside of a mechanical part. Generally the radiation that goes through the material to check, produced an image on a sensitized film. This method requires time because the film needs to be developed, digital radiography has no longer this inconvenient. In digital radiography the film is replaced by digital data and can be processed as any computer file. This new technique is promising but its main inconvenient is that today its resolution is not so good as that of film radiography. (A.C.)

  16. Preliminary results from the application of risk matrix method for safety assessment in industrial radiography; Resultados preliminares de la aplicacion del metodo de matrices de riesgo para evaluaciones de seguridad en radiografia industrial

    Energy Technology Data Exchange (ETDEWEB)

    Lopez G, A.; Cruz, D. [Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan 779, Col. Narvarte, 03020 Ciudad de Mexico (Mexico); Truppa, W. [Autoridad Reguladora Nuclear, Buenos Aires (Argentina); Aravena, M. [Comision Chilena de Energia Nuclear, Santiago (Chile); Tamayo, B., E-mail: alopezg@cnsns.gob.mx [Consejo de Seguridad Nuclear, Madrid (Spain)

    2015-09-15

    Although the uses of ionizing radiation in industry are subject to procedures that provide a high level of safety, experience has shown that equipment failure, human errors, or the combination of both that can trigger accidental exposures may occur. Traditionally, the radiation safety checks whether these industrial practices (industrial radiography, industrial irradiators, among others) are sufficiently safe to prevent similar accidental exposures already occurred, so that becomes dependent on the published information and not always answers questions like: What other events can occur, or what other risks are present? Taking into account the results achieved by the Foro Iberoamericano de Organismos Reguladores Radiologicos y Nucleares, its leading position in the use of techniques of risk analysis in radioactive facilities and the need to develop a proactive approach to the prevention of accidents arising from the use of ionizing radiations in the industry, it intends to apply the risk analysis technique known as Risk Matrix to a hypothetical reference entity for the region in which industrial radiography is performed. In this paper the results of the first stage of this study are shown, that is the identification of initiating events (IE) and barriers that help mitigate the consequences of such IE, so that can appreciate the applicability of this method to industrial radiography services, to reduce the risk to acceptable levels. The fundamental advantage associated with the application of this methodology is that can be applied by the professionals working in the service and identifies specific weaknesses that from the point of view of safety there, so they can be prioritized resources depending on risk reduction. (Author)

  17. X-ray digital industrial radiography (DIR) for local liquid velocity (VLL) measurement in trickle bed reactors (TBRs): Validation of the technique

    Science.gov (United States)

    Mohd Salleh, Khairul Anuar; Rahman, Mohd Fitri Abdul; Lee, Hyoung Koo; Al Dahhan, Muthanna H.

    2014-06-01

    Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (VLL) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the VLL within TBRs.

  18. High definition radiography

    International Nuclear Information System (INIS)

    Parish, R.W.

    1976-01-01

    This paper describes the use of small X and gamma ray sources in industrial radiography. The emphasis is on how they can be used in the ''mass production'' situation or when a large number of tube to tubeplate welds are to be inspected

  19. Assessment of cold neutron radiography capability

    International Nuclear Information System (INIS)

    McDonald, T.E. Jr.; Roberts, J.A.

    1998-01-01

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The authors goals were to demonstrate and assess cold neutron radiography techniques at the Los Alamos Neutron Science Center (LANSCE), Manual Lujan Neutron Scattering Center (Lujan Center), and to investigate potential applications of the capability. The authors have obtained images using film and an amorphous silicon detector. In addition, a new technique they have developed allows neutron radiographs to be made using only a narrow range of neutron energies. Employing this approach and the Bragg cut-off phenomena in certain materials, they have demonstrated material discrimination in radiography. They also demonstrated the imaging of cracks in a sample of a fire-set case that was supplied by Sandia National Laboratory, and they investigated whether the capability could be used to determine the extent of coking in jet engine nozzles. The LANSCE neutron radiography capability appears to have applications in the DOE stockpile maintenance and science-based stockpile stewardship (SBSS) programs, and in industry

  20. Study of black carbon levels in city centers and industrial centers in Jordan

    International Nuclear Information System (INIS)

    Hamasha, K.M.; Almomani, M.S.; Abu-Allaban, M.; Arnott, W. P.

    2010-01-01

    Light absorption coefficients of black carbon (B abc ) were measured at serveral urban and industrial locations in Jordan during summer of 2007 and winter of 2008 using the photoacoustic instrument at a wavelength of 870 nm. Black carbon mass concentration (BC) was calculated using B abc .Black carbon levels at urban locations in the summer of 2007 were higher than those obtained at industrial centers.Zarqa had the highest value of BC in summer (29.24μg/m 3 ) and in winter (13.27μg/m 3 ). Ibbeen and Irbid city center had relatively high values of BC in winter: 11.75μg/m 3 and 12.48μg/m 3 , respectively. (authors).

  1. Euratom Neutron Radiography Working Group

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    In 1979 a Neutron Radiography Working Group (NRWG) was constituted within Buratom with the participation of all centers within the European Community at which neutron facilities were available. The main purpose of NRWG was to standardize methods and procedures used in neutron radiography of nuclear...... reactor fuel as well as establish standards for radiographic image quality of neutron radiographs. The NRWG meets once a year in each of the neutron radiography centers to review the progress made and draw plans for the future. Besides, ad-hoc sub-groups or. different topics within the field of neutron...

  2. Digital radiography

    International Nuclear Information System (INIS)

    Kusano, Shoichi

    1993-01-01

    Firstly, from an historic point of view, fundamental concepts on digital imaging were reviewed to provide a foundation for discussion of digital radiography. Secondly, this review summarized the results of ongoing research in computed radiography that replaces the conventional film-screen system with a photo-stimulable phosphor plate; and thirdly, image quality, radiation protection, and image processing techniques were discussed with emphasis on picture archiving and communication system environment as our final goal. Finally, future expansion of digital radiography was described based on the present utilization of computed tomography at the National Defense Medical College Hospital. (author) 60 refs

  3. 76 FR 1521 - Security Zone: Fleet Industrial Supply Center Pier, San Diego, CA

    Science.gov (United States)

    2011-01-11

    ...-AA87 Security Zone: Fleet Industrial Supply Center Pier, San Diego, CA AGENCY: Coast Guard, DHS. ACTION... Bay, San Diego, CA. The existing zone is around the former Fleet Industrial Supply Center Pier. The... Diego, CA. The existing security zone is around the former Fleet Industrial Supply Center Pier. The...

  4. Radiography at CERN

    CERN Multimedia

    HSE Unit

    2014-01-01

    What is industrial radiography? It is a non-destructive method with a wide variety of applications, such as inspecting the quality of a weld. It uses high-energy radioactive sources or an X-ray generator.   Is this inspection technique used at CERN? Yes, it is widely used at CERN by the EN-MME Group, which outsources the work to one or more companies, depending on the workload. Is it possible to carry out radiography anywhere at CERN? Yes, it is possible to carry out radiography in any building/accelerator/experiment area at CERN (including in areas which are not normally subject to radiological hazards). When is radiography carried out? It normally takes place outside of working hours (7 p.m. to 6 a.m.). How will I know if radiography is taking place in my building? If this activity is planned in a CERN building, notices will be affixed to all of its main entrance doors at least 24 hours in advance. What are the risks? There is a risk of exposure to very high levels of radiation, dep...

  5. The incorporation of User Centered Design and Industrial design

    DEFF Research Database (Denmark)

    Dai, Zheng; Ómarsson, Ólafur

    2011-01-01

    Abstract—Traditional Industrial Design (TID) has been an important aspect in the NPD process within the last decades. User centered design (UCD) is a growing research field for product innovation, starting from the end of 20th century. An NPD process needs support from both design knowledge...... and research methodologies. Both TID and UCD focus on user’s perspective when doing multi-disciplinary work together. They provide skills and methods for designing the style and usability, and balancing the users need and reality. The skills from TID help design expression and realization to communicate...... efficiently with other participants by informative images and real prototypes. The skills from UCD help the idea generation and opportunity discoveries by facilitating workshops and conducting interview with participants. TID and UCD represent different perspectives of the subjective and the objective...

  6. Industrial center of gathering, warehousing and storage. Annual report 2016

    International Nuclear Information System (INIS)

    2016-01-01

    This report first presents the installations of the Cires (industrial center for regrouping, warehousing and storage), its equipment and buildings, its activities (storage of very-low-activity wastes, regrouping and warehousing of non-electronuclear wastes). It reviews the arrangements regarding safety and radiation protection: radioactive waste storage safety, safety of non-electronuclear waste regrouping and warehousing, relationship with the regional directorate of environment, planning and housing (DREAL), quality audits, staff safety, and radiation protection. It addresses the actions undertaken for the monitoring of the environment and of releases by the installations: radiological control in various locations (measurements in soils, waters, underground waters, and atmospheric releases), physical and chemical controls. The next part reports actions regarding transparency and information (visits, conferences, exhibitions, relationship with the local information and control commission)

  7. Industrial center of gathering, warehousing and storage. Annual report 2015

    International Nuclear Information System (INIS)

    2016-01-01

    This report first presents the installations of the Cires (industrial center for regrouping, warehousing and storage), its equipment and buildings, its activities (storage of very-low-activity wastes, regrouping and warehousing of non-electronuclear wastes). It reviews the arrangements regarding safety and radiation protection: radioactive waste storage safety, safety of non-electronuclear waste regrouping and warehousing, relationship with the regional directorate of environment, planning and housing (DREAL), quality audits, staff safety, and radiation protection. It addresses the actions undertaken for the monitoring of the environment and of releases by the installations: radiological control in various locations (measurements in soils, waters, underground waters, and atmospheric releases), physical and chemical controls. The next part reports actions regarding transparency and information (visits, conferences, exhibitions, relationship with the local information and control commission)

  8. Neutron radiography at the HFR Petten

    International Nuclear Information System (INIS)

    Markgraf, J.F.W.

    1990-03-01

    This report contains the five papers on neutron radiography activities at the Petten High Flux Reactor (HFR) presented at the Third World Conference on Neutron Radiography which was held in May 1989 in Osaka, Japan. In addition, a survey on neutron radiography in Europe for industry and research as presented at the SITEF NDT symposium 1989 on European Advances in Non-Destructive Testing, held in Toulouse/France in October 1989 is included. The papers compiled here are concerned with: the neutron radiography services available in Petten; the experience with and applications of neutron radiography at Petten; image evaluation and analysis techniques at Petten; the practical utilization of nitrocellulose film in neutron radiography in Europe; an introduction into the basic principles of neutron radiography; an overview of the neutron radiography facilities in Europe for industry and research; and a survey of typical applications of neutron radiography in industry, research and sciences. It is the intention of this compilation to provide a comprehensive overview of the present Petten activities and European facilities in this young and promising field of non-destructive testing of materials and components from the nuclear and the non-nuclear industries and research organizations, and from the sciences

  9. Quality comparison between DEF-10 digital image from simulation technique and Computed Tomography (CR) technique in industrial radiography

    International Nuclear Information System (INIS)

    Siti Nur Syatirah Ismail

    2012-01-01

    The study was conducted to make comparison of digital image quality of DEF-10 from the techniques of simulation and computed radiography (CR). The sample used is steel DEF-10 with thickness of 15.28 mm. In this study, the sample is exposed to radiation from X-ray machine (ISOVOLT Titan E) with certain parameters. The parameters used in this study such as current, volt, exposure time and distance are specified. The current and distance of 3 mA and 700 mm respectively are specified while the applied voltage varies at 140, 160, 180 and 200 kV. The exposure time is reduced at a rate of 0, 20, 40, 60 and 80 % for each sample exposure. Digital image of simulation produced from aRTist software whereas digital image of computed radiography produced from imaging plate. Therefore, both images were compared qualitatively (sensitivity) and quantitatively (Signal to-Noise Ratio; SNR, Basic Spatial Resolution; SRb and LOP size) using Isee software. Radiographic sensitivity is indicated by Image Quality Indicator (IQI) which is the ability of the CR system and aRTist software to identify IQI of wire type when the time exposure is reduced up to 80% according to exposure chart ( D7; ISOVOLT Titan E). The image of the thinnest wire diameter achieved by radiograph from simulation and CR are the wire numbered 7 rather than the wire numbered 8 required by the standard. In quantitative comparison, this study shows that the SNR values decreases with reducing exposure time. SRb values increases for simulation and decreases for CR when the exposure time decreases and the good image quality can be achieved at 80% reduced exposure time. The high SNR and SRb values produced good image quality in CR and simulation techniques respectively. (author)

  10. Texas A&M University Industrial Assessment Center Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Heffington, Warren M.; Eggebrecht, James A.

    2007-02-24

    This project benefited the public by assisting manufacturing plants in the United States to save costly energy resources and become more profitable. Energy equivalent to over 75,000 barrels of oil was conserved. The Texas A&M University Industrial Assessment Center (IAC) visited 96 manufacturing plants and spent 101 days in those plants during the contract period from August 9, 2002, through November 30, 2006. Recommended annual energy savings for manufacturers were 37,400,000 kWh (127,600 MMBtu—site basis) of electricity and 309,000 MCF (309,000 MMBtu) of natural gas. Each manufacturer subsequently was surveyed, and based on these surveys reportedly implemented 79% of the electricity savings and 36% of the natural gas savings for an overall energy savings of 48% of recommended. Almost 800 (798) projects were recommended to manufacturers, and they accomplished two-thirds of the projects. Cost savings recommended were $12.3 million and implemented savings were $5.7 million or 47%. During the contract period our average time between site visit and report submittal averaged 46 days; and decreased from 48 days in 2003 to 44 days in 2006. Serving clients well and promptly has been a priority. We visited five ESA overflow clients during FY 06. The Texas A&M University IAC pioneered the presentation of air pollution information in reports, and includes NOx and CO2 reductions due to energy savings in all reports. We also experimented with formal PowerPoint BestPractices presentations called Lunchtime/Showtime in each plant and with delivering electronic versions of the report. During the period of the contract, the director served on the Texas Industries of the Future (IOF) Refining and Chemicals Committee, which oversaw the showcases in 2003 and 2006. The assistant director was the Executive Director of the International Energy Technology Conference held annually. The director and assistant director became qualified specialists in the Process Heating Assessment Scoping

  11. A Portable Electron Radiography System

    CERN Document Server

    Merrill, Frank E; Harmon, Frank; Hunt, Alan W; King, B J; Morris, Christopher

    2005-01-01

    The technique of charged particle radiography has been developed and proven with 800 MeV protons at LANSCE and 24 GeV protons at the AGS. Recent work at Los Alamos National Laboratory in collaboration with the Idaho Accelerator Center has extended this diagnostic technique to electron radiography through the development of an inexpensive and portable electron radiography system. This system has been designed to use 30 MeV electrons to radiograph thin static and dynamic systems. The system consists of a compact 30 MeV pulsed electron linear accelerator coupled to a quadrupole lens magnifier constructed from permanent magnet quadrupoles. The design features and operational characteristics of this radiography system are presented as well as the radiographic performance parameters.

  12. Reconstructive dosimetry and radiation doses evaluation of members of the public due to radiological accident in industrial radiography; Dosimetria reconstrutiva e avaliacao de dose de individuos do publico devido a acidente radiologico em radiografia industrial

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Camila Moreira Araujo de

    2016-07-01

    Radiological accidents have occurred mainly in the practices recognized as high risk radiological and classified by the IAEA as Categories 1 and 2, and highlighted the radiotherapy, industrial irradiators and industrial radiography. In Brazil, since there were five major cases in industrial radiography, which involved 7 radiation workers and 19 members of the public, causing localized radiation lesions on the hands and fingers. One of these accidents will be the focus of this work. In this accident, a {sup 192}Ir radioactive source was exposed for more than 8 hours in the workplace inside a company, exposing radiation workers, individuals of the public and people from the surrounding facilities, including children of a school. The radioactive source was also handled by a security worker causing severe radiation injuries in the hand and fingers. In this paper, the most relevant and used techniques of reconstructive dosimetry internationally are presented. To estimate the radiation doses received by exposed individuals in various scenarios of radiological accident in focus, the following computer codes were used: Visual Monte Carlo Dose Calculation (VMC), Virtual Environment for Radiological and Nuclear Accidents Simulation (AVSAR) and RADPRO Calculator. Through these codes some radiation doses were estimated, such as, 33.90 Gy in security worker's finger, 4.47 mSv in children in the school and 55 to 160 mSv for workers in the company during the whole day work. It is intended that this work will contribute to the improvement of dose reconstruction methodology for radiological accidents, having then more realist radiation doses. (author)

  13. Application of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Kobayashi, M.; Wada, N.; Sekita, J.; Sanno-cho, Ota-ku, Tokyo, Japan)

    1983-01-01

    The history and the present state of neutron radiography in Japan are reviewed. Three types of neutron sources, namely nuclear reactors, accelerators and radioisotopes are now used. The interests on the application on neutron radiography become greater and greater in the industries, such as atomic energy, aeronautics and space etc. (Auth.)

  14. Radiography of steel castings by radioisotopes

    International Nuclear Information System (INIS)

    Agrawal, D.K.

    1977-01-01

    The salient features of isotope radiography techniques in the inspections of alloy castings are described. Some of the typical radiographic tests conducted in the Bharat Heavy Electricals Ltd., Bhopal and the problems encountered are described in detail. Specific examples are cited to enlighten the benefits of isotope radiography in heavy industries. (author)

  15. Ambulating radiography

    International Nuclear Information System (INIS)

    Magnusson, K.

    1989-01-01

    Strong gamme or X-ray sources are utilized for non-destructive testing of i.e. bridges. The activities involve certain risks of accident that might lead to serious injuries caused by radiation. The National Institute of Radiation Protection has during the laste decade greatly yhe inspection rate in this area. It has today made controls of most enterprieses running ambulating radiography. (O.S.)

  16. Computed radiography

    International Nuclear Information System (INIS)

    Pupchek, G.

    2004-01-01

    Computed radiography (CR) is an image acquisition process that is used to create digital, 2-dimensional radiographs. CR employs a photostimulable phosphor-based imaging plate, replacing the standard x-ray film and intensifying screen combination. Conventional radiographic exposure equipment is used with no modification required to the existing system. CR can transform an analog x-ray department into a digital one and eliminates the need for chemicals, water, darkrooms and film processor headaches. (author)

  17. Computed radiography

    International Nuclear Information System (INIS)

    Itoh, Hiroshi

    1987-01-01

    In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of simultaneous interpretation of both images in increasing diagnostic accuracy. Structured noise of the ribs and blood vessels had scarcely an effect on nodule detectability in FCR. Radiation dose could be reduced to one third of the standard dose. It can thus be concluded that FCR is feasible in mass screening for lung cancer in terms of increased diagnostic ability and low radiation doses. (Namekawa, K.)

  18. 33 CFR 165.1121 - Security Zone: Fleet Supply Center Industrial Pier, San Diego, CA.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Security Zone: Fleet Supply... Guard District § 165.1121 Security Zone: Fleet Supply Center Industrial Pier, San Diego, CA. (a... feet from the north, west, and south sides of the Fleet Industrial Supply Center enclosed by lines...

  19. Energy Efficient Industrialized Housing Research Program, Center for Housing Innovation, University of Oregon and the Florida Solar Energy Center

    Energy Technology Data Exchange (ETDEWEB)

    Brown, G.Z.

    1990-01-01

    This research program addresses the need to increase the energy efficiency of industrialized housing. Two research centers have responsibility for the program: the Center for Housing Innovation at the University of Oregon and the Florida Solar Energy Center, a research institute of the University of Central Florida. The two organizations provide complementary architectural, systems engineering, and industrial engineering capabilities. In 1989 we worked on these tasks: (1) the formation of a steering committee, (2) the development of a multiyear research plan, (3) analysis of the US industrialized housing industry, (4) assessment of foreign technology, (5) assessment of industrial applications, (6) analysis of computerized design and evaluation tools, and (7) assessment of energy performance of baseline and advanced industrialized housing concepts. The current research program, under the guidance of a steering committee composed of industry and government representatives, focuses on three interdependent concerns -- (1) energy, (2) industrial process, and (3) housing design. Building homes in a factory offers the opportunity to increase energy efficiency through the use of new materials and processes, and to increase the value of these homes by improving the quality of their construction. Housing design strives to ensure that these technically advanced homes are marketable and will meet the needs of the people who will live in them.

  20. Industrial Uses of Neutron Scattering

    Science.gov (United States)

    Priesmeyer, Hans Georg

    Recent progress in neutron scattering for industrial purposes is reviewed. The relevant fields of interest are small-angle scattering, high-resolution diffraction, texture determination, reflectometry and radiography. Potential users are encouraged to address themselves to one of the neutron scattering centers given in the Appendix.

  1. Digital radiography

    International Nuclear Information System (INIS)

    Coulomb, M.; Dal Soglio, S.; Pittet-Barbier, L.; Ranchoup, Y.; Thony, F.; Ferretti, G.; Robert, F.

    1992-01-01

    Digital projection radiography may replace conventional radiography some day, provided it can meet several requirements: equal or better diagnostic effectiveness of the screen-film systems; reasonable image cost; real improvement in the productivity of the Departments of Imaging. All digital radiographic systems include an X-ray source, an image acquisition and formatting sub-system, a display and manipulation sub-system, and archiving subsystem and a laser editing system, preferably shared by other sources of digital images. Three digitization processes are available: digitization of the radiographic film, digital fluorography and phospholuminescent detectors with memory. The advantages of digital fluoroscopy are appealing: real-time image acquisition, suppression of cassettes; but its disadvantages are far from negligible: it cannot be applied to bedside radiography, the field of examination is limited, and the wide-field spatial resolution is poor. Phospholuminescent detectors with memory have great advantages: they can be used for bedside radiographs and on all the common radiographic systems; spatial resolution is satisfactory; its current disadvantages are considerable. These two systems, have common properties making up the entire philosophy of digital radiology and specific features that must guide our choice according to the application. Digital fluorography is best applied in pediatric radiology. However, evaluation works have showed that it was applicable with sufficient quality to many indications of general radiology in which a fluoroscopic control and fast acquisition of the images are essential; the time gained on the examination may be considerable, as well as the savings on film. Detectors with memory are required for bedside radiographs, in osteoarticular and thoracic radiology, in all cases of traumatic emergency and in the resuscitation and intensive care departments

  2. Radiography apparatus

    International Nuclear Information System (INIS)

    Sashin, D.; Sternglass, E.J.

    1982-01-01

    The apparatus of the present invention provides radiography apparatus wherein the use of a flat, generally rectangular beam or a fan-shaped beam of radiation in combination with a collimator, scintillator and device for optically coupling a self-scanning array of photodiodes to the scintillator means will permit production of images or image data with high contrast sensitivity and detail. It is contemplated that the self-scanning array of photodiodes may contain from about 60 to 2048, and preferably about 256 to 2048, individual photodiode elements per inch of object width, thereby permitting maximum data collection to produce a complete image or complete collection of image data

  3. Radiography shielding

    Energy Technology Data Exchange (ETDEWEB)

    Redmayne, I.

    1985-11-27

    Apparatus for the inspection of a pipe weld by radiography comprises a radiation source contained in a housing having a first collimator for defining the exit beam and a second collimator mountable on the pipe in the region of the weld to define with the first collimator a predetermined volume enclosing the radiation beam passing through the second collimator when the housing is in a predetermined position relative to the second collimator. The arrangement is such that if the housing is slightly displaced from the predetermined position the radiation beam still falls within the predetermined volume.

  4. Radiography shielding

    International Nuclear Information System (INIS)

    Redmayne, I.

    1985-01-01

    Apparatus for the inspection of a pipe weld by radiography comprises a radiation source contained in a housing having a first collimator for defining the exit beam and a second collimator mountable on the pipe in the region of the weld to define with the first collimator a predetermined volume enclosing the radiation beam passing through the second collimator when the housing is in a predetermined position relative to the second collimator. The arrangement is such that if the housing is slightly displaced from the predetermined position the radiation beam still falls within the predetermined volume. (author)

  5. Digital radiography

    International Nuclear Information System (INIS)

    Elander, S.; Hellesnes, J.; Reitan, J.B.

    1992-01-01

    The technology of radiography is developing rapidly, both regarding imaging technology and data hardware, and software technology. More and more advanced systems are marketed by the radiological companies. The wide product range makes it difficult to get an overview over principles and components. By closer inspection, however, the number of basic components and technologies is limited. Moreover, the components seem rather well known from other technologies, due to the long times of development in radiology. This report gives a survey of some new principles and components in the video chain. As components may deteriorate or age fast by irradiation, the radiation levels in the chain are evaluated. 13 refs

  6. Digital Radiography

    Science.gov (United States)

    1986-01-01

    System One, a digital radiography system, incorporates a reusable image medium (RIM) which retains an image. No film is needed; the RIM is read with a laser scanner, and the information is used to produce a digital image on an image processor. The image is stored on an optical disc. System allows the radiologist to "dial away" unwanted images to compare views on three screens. It is compatible with existing equipment and cost efficient. It was commercialized by a Stanford researcher from energy selective technology developed under a NASA grant.

  7. Analysis of performance in radiation protection of the industrial radiography facilities in Brazil in the period of 1995 to 1997

    International Nuclear Information System (INIS)

    Oliveira de Aquino, J.; Barbosa Teixeira, P.; De Souza, L.A.

    1998-01-01

    Accomplishment of irregularities analysis verified in the industrial X-ray facilities in the period of 1995 to 1997, containing the following information: number of facilities, irregularities, classification, occurrence frequency and number of accomplished inspections. This work discusses some articles of radiation protection put in practice in the period in study, as well as some suggestions that they could be implemented, with the objective of perfecting the radiation protection of the facilities and the control accomplished by the CNEN

  8. Collaborative Innovation Research on High-tech Industry in the Center Delta

    Directory of Open Access Journals (Sweden)

    Yan Jingdong

    2017-01-01

    Full Text Available As a strong point in the Middle Rises Strategy, the Center Delta is of great significance to high-tech industry development. While the collaborative innovation is an effective way to promote the coordinated development of regional economy. This article selected electronic and communication equipment manufacturing industry of 3 provinces in the Center Delta as samples, built evaluation index system of collaborative innovation of high-tech industry, and put the relevant data into the system coordination degree model, in order to get the synergy of industrial innovation system and innovation environment system of 3 provinces. The empirical results shown that the industrial innovation system and innovation environment system coordination degree of Hubei province was the highest, while Jiangxi province was the lowest. Based on the empirical result analysis of the above-mentioned systems, this article put forward suggestions to promote the development of the high-tech industry collaborative innovation in the Center Delta.

  9. Current NDT activities at Cekmece Nuclear Research and Training Center

    International Nuclear Information System (INIS)

    Ekinci, S.

    2004-01-01

    Nondestructive testing (NDT) activities at Cekmece Nuclear Research and Training Center (CNAEM) has been initiated in the Industrial Application Department of the Center which was established in 1976 as the Radioisotope Applications Group for Industry. The Department started its first NDT activity with industrial radiography. The NDT activities have been developed by the support of various national (State Planning Organization (DPT)) and international (IAEA and UNDP) projects. Today, there are five basic NDT techniques (radiography, ultrasonic, magnetic particle, liquid penetrant and eddy current) used in the Industrial Application Department. The Department arranges routinely NDT qualification courses according to ISO 9712 and TS EN 473 standards for level 1 and 2 for Turkish Industry. It also carries out national DPT and IAEA Technical Co-operation projects and gives NDT services in the laboratory and in the field. Digital radiography and digital ultrasonic techniques are being used in advanced NDT applications. This paper describes the NDT activities of CNAEM. (author)

  10. Equipment for x- and gamma ray radiography

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following topics related to the equipment for x - and gamma ray radiography are discussed in this chapter. The topics are x-ray source for Industrial Radiography: properties of x-ray, generation of x-ray, mechanism of x-ray production, x-ray equipment, power supply, distribution of x-ray intensity along the tube: gamma ray source for Industrial Radiography: properties of gamma rays, gamma ray sources, gamma ray projectors on cameras, source changing. Care of Radiographic Equipments: Merits and Demerits of x and Gamma Rays

  11. Certificate of competence for the use of industrial radiography equipment - CAMARI. 2011 annual status - Organisation, results and perspectives

    International Nuclear Information System (INIS)

    Le Dirac'h, B.

    2012-01-01

    Since 2008, IRSN has been organizing the tests of the review of CAMARI (licence for using radiological installations for industry in France) in technical support of the ministry's work. This report, by reminding the modalities of the examination, supplies a synthesis of the results obtained by the candidates in 2011. The exam's organization set up by IRSN, provides a summary of results obtained by candidates in 2011. It also provides the balance sheet over the period 2008-2011 and suggests axes of improvement. (author)

  12. Students Experience in Radiography

    International Nuclear Information System (INIS)

    Nyambane, K.D.; Faith Wanjiku Kimunge, W.F.

    2015-01-01

    The Radiography Students from Jomo Kenyatta University of Agriculture and Technology, Kenya share experiences of College Experience, Challenges, Myths and the Radiography dream. The Cultural shock and expectations towards Radiography has changed for the first timers’ students in the radiography class. This has motivated them to remove the fear of the unknown and negatives effects of radiation

  13. Management of radioactive waste of scientific and industrial centers

    International Nuclear Information System (INIS)

    Sobolev, I.A.; Dmitriev, S.A.; Barinov, A.S.; Ojovan, M.I.; Timofeev, E.M.

    1995-01-01

    Available for the time being in the Russian Federation, a system of management of institutional and industrial radioactive waste (e.g. radioactive waste from industry, medicine, scientific organizations and other, which are not related to the nuclear fuel cycle or defense) provides for its collection, transportation, storage, treatment, immobilization and disposal by a network of special enterprises. Russia has 16 such enterprises. Moscow Scientific and Industrial Association Radon deals with the problems of radioactive waste from Central European part of Russia, which includes Moscow, Moscow Region and also Tverskaya, Yaroslavskaya, Vladimirskaya, Kostromskaya, Kaluzhskaya, Bryanskaya, Smolenskaya, Tulskaya, Ryazanskaya regions. The population of the central part of Russia constitutes about 40 million people. At the same time about 80% of the radioactive waste, which is collected for treatment and disposal from the territory of Russia, is included in this region. The average volume of the waste to be treated at SIA Radon is 3,000 m 3 per year for solid waste and 350 m 3 per year for liquid waste. Total radioactivity of processed waste is up to 4 PBq per year

  14. Role of Industrial Relations Centers in the Education of Personnel Managers

    Science.gov (United States)

    Rezler, Julius

    1971-01-01

    New or modified functions and responsibilities require personnel managers to obtain additional knowledge, techniques and skills. Two alternatives are available: the Master of Business Administration program or programs offered in industrial relations centers. (EB)

  15. Neutron radiography

    International Nuclear Information System (INIS)

    Pugliesi, R.; Freitas, A.G. de; Gammal, A.; Rizzatti, M.R.; Vercelli, P.

    1990-01-01

    The objective was to demonstrate the main characteristics of the neutron radiography technique, which has been developed in the Nuclear Physics Department of the IPEN-CNEN-SP. Its employment, in technology varies enormously and includes among others, the inspection of the hydrogen-rich substances, highly radioactive materials, etc. The indirect conversion method with Dysprosium screen was employed. The experimental arrangement used was a neutron collimator installed in the bottom of the IEA-R1 Nuclear Research Reactor pool. Several samples were analysed which were exposed in a neutron flux ∼ 10 7 n/s.cm 2 during 10 minutes. The obtained results confirm the main characteristics of this technique as well as its viability to be developed in this reactor. (author)

  16. Radiography exposure

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    This chapter, the reader will introduce with basic knowledge on radiography exposure. All the code and standard must give a specification on density or their range that can accepted. So the result outside the specification usually will be unacceptable and this can effected the time, cost and energy of the radiographer. So, for radiographer, they must work carefully to produce a good result and one way to solve this problem is through good exposure. The more the exposure can make a film darker while the less exposure can make the radiograph not enough density. So, through this chapter, the reader can know detailed how to manage this problem. As mention earlier, this technique is a combination between theories and practical, so, here theory is a main part to make the practical successful.

  17. Electron radiography

    Science.gov (United States)

    Merrill, Frank E.; Morris, Christopher

    2005-05-17

    A system capable of performing radiography using a beam of electrons. Diffuser means receive a beam of electrons and diffuse the electrons before they enter first matching quadrupoles where the diffused electrons are focused prior to the diffused electrons entering an object. First imaging quadrupoles receive the focused diffused electrons after the focused diffused electrons have been scattered by the object for focusing the scattered electrons. Collimator means receive the scattered electrons and remove scattered electrons that have scattered to large angles. Second imaging quadrupoles receive the collimated scattered electrons and refocus the collimated scattered electrons and map the focused collimated scattered electrons to transverse locations on an image plane representative of the electrons' positions in the object.

  18. Neutron resonance radiography: Report of a workshop, Los Alamos, NM: July 27-29, 1987

    International Nuclear Information System (INIS)

    1988-07-01

    Neutron resonance radiography is a new technique with great potential for non-destructive analysis and testing. This technique has been under research and development in a number of major research laboratories for some time. Unlike thermal neutron radiography, which is primarily oriented towards imaging hydrogen and a number of other highly neutron-absorptive materials without necessarily distinguishing between them, neutron resonance radiography has the capability of uniquely identifying many kinds of chemical elements and their individual isotopes. It also has the potential for temperature imaging in materials containing heavy elements and for certain dynamic features such as stroboscopic imaging. Although neutron resonance radiography has not yet been taken up in a systematic way for technological applications, significant development of ideas and instrumentation at the research level has blossomed. There have also been major developments in the availability of powerful pulsed-neutron sources. In light of these developments, the Los Alamos Neutron Scattering Center sponsored a workshop with the general aims of reviewing scientific and technical progress, discussing and highlighting future developments, and stimulating interest in technological exploitation of the methods. In addition to the techniques and instrumentation required for the field, the applications of neutron resonance radiography in some of the following industrial and manufacturing areas were discussed: nuclear fuel assay; nuclear safeguards in general; aerospace development (aeroengine blade temperature, stroboscopic techniques); diagnostics; non-nuclear industry (especially metallurgy); temperature imaging; use of mobile pulsed-neutron sources; and practical use of major pulsed-neutron facilities

  19. Portable digital electronic radiography system

    International Nuclear Information System (INIS)

    Sawicka, B.D.

    1995-01-01

    Radiography is a standard nondestructive technique in the industrial testing of materials and components. It is routinely used during the construction, maintenance and repair of nuclear plants. Traditionally, radiography is performed using photographic film (film radiography, FR). Recent developments in solid-state area imaging radiation detectors, miniature electronics and computer software/hardware techniques have brought electronic alternatives to FR. In recent years various electronic radiography (ER) techniques have served as alternatives to FR, these proved beneficial in some applications. While originally developed to provide real time imaging, ER may offer other advantages over FR, depending on the application. Work was undertaken at CRL to review progress in ER techniques and evaluate the possibility of constructing a portable DER (digital electronic radiography) system, for the inspection of power plant components. A suitable DER technique has been developed and a proof of principle portable system constructed. As this paper demonstrates, a properly designed ER system can be small and compact, while providing radiographic examination with acceptable image quality and the benefits of ER imaging. The CRL DER system can operate with radioactive sources typical of FR. While it does not replace FR, our DER system is expected to be beneficial in specific applications for Candu maintenance, reducing cost, labour and time. Practical, cost saving applications of this system are expected to include valve monitoring and foreign object location during maintenance at Candu reactors

  20. Academic Centers and/as Industrial Consortia: US Microelectronics Research 1976-2016

    NARCIS (Netherlands)

    Mody, Cyrus C.M.

    2017-01-01

    In the U.S., in the late 1970s and early 1980s, academic research centers that were tightly linked to the semiconductor industry began to proliferate – at exactly the same time as the first academic start-up companies in biotech, and slightly before the first U.S. industrial semiconductor research

  1. 1998 researchers' conference proceedings, Amarillo College Business and Industry Center

    International Nuclear Information System (INIS)

    1998-01-01

    The first Strategic Arms Reduction Treaties (START 1 and 2) signed by the US and the Soviet Union call for a reduction in strategic nuclear warheads to about one-third of 1990 levels and a complete elimination of land-based, multiple-warhead missiles. As a consequence of dismantling nuclear warheads, a significant portion of the inventory of nuclear materials that were formerly parts of deployed weapon systems was designated to be handled and/or stored at the Pantex Plant near Amarillo, Texas. To facilitate research integration between the national laboratories and the universities, the Center has divided its technical activities into seven focus areas. For Nuclear and Other Materials Studies, the focus areas are Materials Science, Plutonium Processing and handling, Nuclear Materials Storage, and analytical Development. The Environment, Safety and Health focus areas are Environmental Restoration and Protection, Safety and Health, and Waste Management. Research projects within each area are presented

  2. Evaluation of radiological safety conditions of panoramic portable irradiators of industrial radiography used in Brazil; Avaliacao das condicoes de seguranca radiologica de irradiadores portateis panoramicos de gamagrafia industrial utilizados no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Josilto Oliveira de

    2003-08-01

    In Brazil, the applications of ionizing radiation in industrial area are performed in about 900 installations, in which around 3000 radioactive sources are handled. Industrial radiography represents 14 % of this total, with 217 X rays equipment and 287 gamma radiography apparatus, according to a survey conducted in the present work. From these gamma apparatus, 90 % employ {sup 192} Ir sources, followed by {sup 60} Co and {sup 75} Se, with 5 % each. The great majority of the {sup 192} Ir apparatus have been in continuous usage in Brazil for more than 20 years, which means that they are old equipment. The totality of the 11 models of {sup 192} Ir apparatus used in Brazil is imported from abroad. Those apparatus are portable, and almost all operate according to category II, i.e., the source assembly is mechanically projected out of the container. This last characteristic, besides the fact that the apparatus are already old-fashioned and worn-out, raises concerns about their radiological safety. The main objective of this work was to develop a specific methodology for inspection, testing and assessment of the radiological safety devices and state of maintenance of the {sup 192} Ir apparatus. The idea is to prevent accidents, as physical failures can lead to overexposure of working staffs. In order to accomplish this, almost a hundred {sup 192} Ir apparatus, from the 11 models used in Brazil, were studied. According to our results, almost 20 % of the 97 apparatus evaluated presented some kind of unsafe condition for proper operation, like poor state of maintenance and faults at the lock that retains the source at the secure position. From the 11 imported models of {sup 192} Ir apparatus in use in Brazil, six models were already manufactured incorporating the safety devices specified by the first edition of the Standard ISO 3999, edited in 1977. However, five models do not comply even with this first edition of the Standard ISO 3999. Thus, they lack some important and

  3. Neutron radiography using small cyclotrons

    International Nuclear Information System (INIS)

    Nishihara, Yoshiaki; Tarumi, Yuji; Ozaki, Masakazu; Kakihira, Shoji; Tazawa, Shuichi; Nakanii, Takehiko

    1995-01-01

    For neutron radiography, as a neutron source, a small cyclotron has been used in this facility, which was developed for the production of short life radioisotopes by Sumitomo Heavy Industries Ltd. Further, the development of the use of fast ion beam for industrial fields has been advanced, Neutron radiography was carried out earliest in 1983, and thereafter, the activation analysis using charged particles, the ion irradiation to semiconductor elements, the measurement of wear by using the nuclides produced with the cyclotron as the tracer and so on have been performed. The specification of this neutron radiography facility is shown. The method of irradiating proton beam to a beryllium target is adopted. The features of the moderator, the device for improving neutron flux, the collimators and so on are explained. The heightening of neutron characteristics by the improvement of the moderator is shown. Thermal neutrons have the large cross section of absorption or scattering in hydrogen and special elements, and show the transparent property in general metals. Accordingly, the have the merit that the photographing of good contrast can be done for the hydrocarbon materials in metallic enclosures. The examples of the application of thermal neutron radiography to space rockets, aircrafts, automobiles and others are shown. (K.I.)

  4. Neutron radiography

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi

    1988-01-01

    The thermal neutron absorption coefficient is essentially different from the X-ray absorption coefficient. Each substance has a characteristic absorption coefficient regardless of its density. Neutron deams have the following features: (1) neutrons are not transmitted efficiently by low molecular weight substances, (2) they are transmitted efficiently by heavy metals, and (3) the transmittance differs among isotopes. Thus, neutron beams are suitable for cheking for foreign matters in heavy metals and testing of composites consisting of both heavy and light materials. A neutron source generates fast neutrons, which should be converted into thermal neutrons by reducing their energy. Major neutron souces include nuclear reactors, radioisotopes and particle accelerators. Photographic films and television systems are mainly used to observe neutron transmission images. Computers are employed for image processing, computerized tomography and three-dimensional analysis. The major applications of neutron radiography include inspection of neclear fuel; evaluation of material for airplane; observation of fuel in the engine and oil in the hydraulic systems in airplanes; testing of composite materials; etc. (Nogami, K.)

  5. A Descriptive Study towards Green Computing Practice Application for Data Centers in IT Based Industries

    Directory of Open Access Journals (Sweden)

    Anthony Jnr. Bokolo

    2018-01-01

    Full Text Available The progressive upsurge in demand for processing and computing power has led to a subsequent upsurge in data center carbon emissions, cost incurred, unethical waste management, depletion of natural resources and high energy utilization. This raises the issue of the sustainability attainment in data centers of Information Technology (IT based industries. Green computing practice can be applied to facilitate sustainability attainment as IT based industries utilizes data centers to provide services to staffs, practitioners and end users. But it is a known fact that enterprise servers utilize huge quantity of energy and incur other expenditures in cooling operations and it is difficult to address the needs of accuracy and efficiency in data centers while yet encouraging a greener application practice alongside cost reduction. Thus this research study focus on the practice application of Green computing in data centers which houses servers and as such presents the Green computing life cycle strategies and best practices to be practiced for better management in data centers in IT based industries. Data was collected through questionnaire from 133 respondents in industries that currently operate their in-house data centers. The analysed data was used to verify the Green computing life cycle strategies presented in this study. Findings from the data shows that each of the life cycles strategies is significant in assisting IT based industries apply Green computing practices in their data centers. This study would be of interest to knowledge and data management practitioners as well as environmental manager and academicians in deploying Green data centers in their organizations.

  6. Decree No85-968 of 27 August 1986 amending Article R.233-83 of the Labour Code and defining the health and safety conditions to be met by gamma industrial radiography equipment

    International Nuclear Information System (INIS)

    1986-01-01

    This Decree, amending Article R 233-83 of the Labour Code, applies to gamma-ray industrial radiography equipment whether mobile or fixed. It contains specific technical conditions concerning the equipment, in particular, safety devices located at the entry and exit points of the source's shield. The equipment must carry a notice mentioning''Radioactive''prepared by the constructor or the importer of the source, which explains the conditions for handling, setting-up, use and maintenance of the source, including the frequency of revisions. The Decree entered into force on 1 June 1986. (NEA) [fr

  7. Radiography With the Patient in the centre

    DEFF Research Database (Denmark)

    Møller, Louise

    2016-01-01

    The health care system is becoming more technological, and at the same time, it is verbalized that the patient should be in the center. The purpose of this study was to illucidate how radiography with the patient in the center is performed and what patients and radiographers understand about center...... in radiography. Qualitative methods was used; observations of three MR scans and interviews with three patients and three radiographers are discussed. In the description of an MR scan, it appeared that more elements are involved and that each element has a center of equal importance to complete the MR scan....... Several of these elements have a technical focus. There are relations in an MR scan affecting which actions are included in the scan pathway. However, it is the radiographers who decide which actions to include. Patients and radiographers in this study agreed that center in radiography is about directing...

  8. International Neutron Radiography Newsletter

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    At the First World Conference on Neutron Radiography i t was decided to continue the "Neutron Radiography Newsletter", published previously by J.P. Barton, as the "International Neutron Radiography Newsletter" (INRNL), with J.C. Doraanus as editor. The British Journal of Non-Destructive Testing...

  9. Non destructive testing of industrial pieces by radiography: quantitative characterization and 3 D reconstruction by the way of a limited number of images; Controle non destructif de pieces industrielles par radiographie: caracterisation quantitative et reconstruction 3D a partir d`un nombre limite de vues

    Energy Technology Data Exchange (ETDEWEB)

    Retraint, F

    1998-12-31

    The non destructive testing of industrial pieces is evaluated on the basis of numerical radiographies.The context of the study is the online control of the fuel rods production. A direct model of a numerical radiography formation is proposed and detailed for an acquisition system consisting of a CCD video connected to a converter screen by an optical system. As this approach does not allow the determination of the measured matter thickness from the X-ray photograph, an approximate model based on realistic approximations of the industrial non destructive testing, has been developed. For the specific cases it is possible to inverse the model and to reach the quantitative information present in the x-ray photograph, in other words, the map of the X-rays measured matter thickness. It becomes then possible to access to the quantitative parameters of the possible defects present in the measured specimen, such as the surface and the bulk. To reach the 3 D information on the defects a 3 D reconstruction method, from 3 X-rays photographs, is proposed.The inverse problem is solved by the non convex energy minimization. (A.L.B.) 109 refs.

  10. Characterization and adjustment of the neutron radiography facility of the RP-10 nuclear reactor

    International Nuclear Information System (INIS)

    Ravello R, Y.R.

    2001-01-01

    The main aim of this work was to characterize and adjust the neutron radiography facility of the RP-10 nuclear reactor, and therefore be able to offer with this technique services to the industry and research centers in general. This technique will be complemented with others such as x-rays and gamma radiography. First, the shielding capacity of the facility was analyzed, proving that it complies with the radiological safety requirements established by the radiological safety code. Then gamma filtration tests were conducted in order to implement the direct method for image formation, optical density curves were built according to the thickness of the gamma filter, the type of film and the type of irradiation. Also, the indirect method for image formation was implemented for two types of converters: indium and dysprosium. Growth curves for optical density were also made according to contact time between converter-film, for different types of films. The resolution of the facility was also analyzed using two methods: Klasens (1946) and Harms (1986). Harms method came closer to the resolution of the human eye when compared to the Klasens method. Finally, the application fields of neutron radiography are presented, including those conducted at the neutron radiography facility of the RP-10 nuclear reactor. With this work, the RP-10 neutron radiography facility is ready to offer inspection and research services

  11. Combining total energy and energy industrial center concepts to increase utilization efficiency of geothermal energy

    Science.gov (United States)

    Bayliss, B. P.

    1974-01-01

    Integrating energy production and energy consumption to produce a total energy system within an energy industrial center which would result in more power production from a given energy source and less pollution of the environment is discussed. Strong governmental support would be required for the crash drilling program necessary to implement these concepts. Cooperation among the federal agencies, power producers, and private industry would be essential in avoiding redundant and fruitless projects, and in exploiting most efficiently our geothermal resources.

  12. Criteria of the effectiveness of a liaison center for the machine building industry

    International Nuclear Information System (INIS)

    Hofer, P.; Wolff, H.; Franzen, D.; Schlichting, J.; Weidig, I.

    1978-04-01

    The study aimed at working out a catalogue of criteria for the effective work of a liaison center for the machine building industry within the planned system of information and documentation of the German Government. By selecting this objective, the investigation methodically demanded a continuous change between theoretical analysis (study of literature, analytical deduction of the framework for a user-oriented information system) and empirical observation of information behaviour in the machine building industry (personal interviews with enterprises and important information sources for the machine building industries). An information system keyed to the information needs of the machine building industry must cover three main phases: Collection and documentation of information, selecting and procuring the needed information as well as encouraging and consulting the clients on the use of information. These different tasks complement one another, they correspond to different functions within enterprises: management, staff, and information function. Central point of a liaison center must be the task of selecting the required information (making information available, selling good information, analysing the information needs of clients), completed by fields of activity in documenting information (specifically for the machine building industry) and consulting clients on the use of information (agency for contacts, drawing the client's attention to the complexity of machine building problems). A concrete catalogue of criteria for an effective conception of a liaison center for the machine building industry has been worked out. (orig.) [de

  13. A regional technology transfer program. [North Carolina Industrial Applications Center for the Southeast

    Science.gov (United States)

    1979-01-01

    The proliferation of online searching capabilities among its industrial clients, changes in marketing staff and direction, use of Dun and Bradstreet marketing service files, growth of the Annual Service Package program, and services delivered to clients at the NASA funded North Carolina Science and Technology Research Center are described. The library search service was reactivated and enlarged, and a survey was conducted on the NC/STRC Technical Bulletin's effectiveness. Several quotations from clients assess the overall value of the Center's services.

  14. Digital radiography of the thorax

    International Nuclear Information System (INIS)

    Frija, J.; Kerviler, E. de; Zagdanski, A.M.; Feger, C.; Attal, P.; Laval-jeantet, M.

    1997-01-01

    Digital radiography of the thorax can, now be substituted to conventional chest radiography. Computed radiography with phosphor plates and the new selenium detector are emphasized. The major image processing are explained. Successively the main other methods of digital radiography are described: scanning equalization radiography, laser-digitized radiography and multiwire proportional chambers. Then the advantages and the drawbacks of chest computed radiography are extensively reviewed. (author)

  15. The Role of Industrial Relations Centers, Proceedings of a Regional Meeting of the International Industrial Relations Association (Chicago, May 17-18, 1968).

    Science.gov (United States)

    Wisconsin Univ., Madison. Industrial Relations Research Inst.

    This meeting was held to exchange views on organization, operation, and goals of industrial relations centers, institutes, and schools. The opening speaker outlined the structure and functions of the international organization and of the regional conferences. The first paper, "Administrative Arrangements in Industrial Relations Centers," was based…

  16. Preparing Teachers for Place-Based Instruction at the Tsongas Industrial History Center

    Science.gov (United States)

    Greenwood, Anita; Kirschbaum, Sheila

    2014-01-01

    In spite of the economic climate which has led to financial retrenchment in school districts, the Tsongas Industrial History Center (TIHC) in Lowell, Massachusetts, which was formed through a collaboration between the National Park Service Lowell National Historical Park and the University of Massachusetts Lowell Graduate School of Education,…

  17. A Method for User Centering Systematic Product Development Aimed at Industrial Design Students

    Science.gov (United States)

    Coelho, Denis A.

    2010-01-01

    Instead of limiting the introduction and stimulus for new concept creation to lists of specifications, industrial design students seem to prefer to be encouraged by ideas in context. A new method that specifically tackles human activity to foster the creation of user centered concepts of new products was developed and is presented in this article.…

  18. Linguistic Globalization and the Call Center Industry: Imperialism, Hegemony or Cosmopolitanism?

    Science.gov (United States)

    Sonntag, Selma K.

    2009-01-01

    Linguistic imperialism, linguistic hegemony and linguistic cosmopolitanism are broad and contrasting conceptualizations of linguistic globalization that are frequently, if implicitly, invoked in the literature, both academic and non-academic, on language practices and perceptions in the call center industry. I begin with outlining each of these…

  19. Digital radiography: study of an alternative technique to conventional radiography; La Radiographie Numerique: etude d'une technique alternative a la radiographie conventionnelle

    Energy Technology Data Exchange (ETDEWEB)

    Banchet, J. [AREVA, AREVA NP, NETEC, The Areva Nondestructive Examination Technical Center, 69 - Lyon (France); Tisseur, D. [AREVA, AREVA NP, Intercontrole, 71 - Chalon sur Saone (France); Thomas, A. [AREVA, AREVA NP, 92 - Colombes (France)

    2009-07-01

    Digital radiography, already in use in many industrial applications, appears as a potential alternative technique to conventional radiography in the nuclear field (and more especially to the inspection of welded joints). The advantages of digital radiography are a reduced explosion risk (due to the use of lower energy and activity sources), a lower installation time, a reduced exclusion zone, and the absence of effluents. However, to the contrary of the US case, this technique may not be used in France as it is not referenced in the regulating codes (RCCM, etc.). Areva has launched a R and D study in order to characterize the equivalencies between digital and conventional radiography. First results of this study are given

  20. [Shifting path of industrial pollution gravity centers and its driving mechanism in Pan-Yangtze River Delta].

    Science.gov (United States)

    Zhao, Hai-Xia; Jiang, Xiao-Wei; Cui, Jian-Xin

    2014-11-01

    Shifting path of industrial pollution gravity centers is the response of environmental special formation during the industry transfer process, in order to prove the responding of industrial pollution gravity centers to industry transfer in economically developed areas, this paper calculates the gravity centers of industrial wastewater, gas and solid patterns and reveals the shifting path and its driving mechanism, using the data of industrial pollution in the Pan-Yangtze River Delta from 2000 to 2010. The results show that the gravity center of the industrial waste in Pan-Yangtze River Delta shifts for sure in the last 10 years, and gravity center of solid waste shifts the maximum distance within the three wastes, which was 180.18 km, and shifting distances for waste gas and waste water were 109.51 km and 85.92 km respectively. Moreover, the gravity center of the industrial waste in Pan-Yangtze River Delta shifts westwards, and gravity centers of waste water, gas and solid shift for 0.40 degrees, 0.17 degrees and 0.03 degrees respectively. The shifting of industrial pollution gravity centers is driven by many factors. The rapid development of the heavy industry in Anhui and Jiangxi provinces results in the westward shifting of the pollutions. The optimization and adjustment of industrial structures in Yangtze River Delta region benefit to alleviating industrial pollution, and high-polluting industries shifted to Anhui and Jiangxi provinces promotes pollution gravity center shifting to west. While the development of massive clean enterprise, strong environmental management efforts and better environmental monitoring system slow the shifting trend of industrial pollution to the east in Yangtze River Delta. The study of industrial pollution gravity shift and its driving mechanism provides a new angle of view to analyze the relationship between economic development and environmental pollution, and also provides academic basis for synthetical management and control of

  1. In-motion radiography speeds tank weld inspection

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    Moving on in-motion x-ray is used for inspections of tanks used for food, beverage, chemical industry, and nuclear reactors. In-motion x radiography is faster and is 60% of the cost of conventional radiography. There is little scatter radiation because the head is so close to the seam

  2. Evidence-based radiography

    International Nuclear Information System (INIS)

    Hafslund, Bjorg; Clare, Judith; Graverholt, Birgitte; Wammen Nortvedt, Monica

    2008-01-01

    Evidence-based practice (EBP) offers the integration of the best research evidence with clinical knowledge and expertise and patient values. EBP is a well known term in health care. This paper discusses the implementation of EBP into radiography and introduces the term evidence-based radiography. Evidence-based radiography is radiography informed and based on the combination of clinical expertise and the best available research-based evidence, patient preferences and resources available. In Norway, EBP in radiography is being debated and radiographers are discussing the challenges of implementing EBP in both academic and clinical practice. This discussion paper explains why EBP needs to be a basis for a radiography curriculum and a part of radiographers' practice. We argue that Norwegian radiographers must increase participation in research and developing practice within their specific radiographic domain

  3. Development of a framework of human-centered automation for the nuclear industry

    International Nuclear Information System (INIS)

    Nelson, W.R.; Haney, L.N.

    1993-01-01

    Introduction of automated systems into control rooms for advanced reactor designs is often justified on the basis of increased efficiency and reliability, without a detailed assessment of how the new technologies will influence the role of the operator. Such a ''technology-centered'' approach carries with it the risk that entirely new mechanisms for human error will be introduced, resulting in some unpleasant surprises when the plant goes into operation. The aviation industry has experienced some of these surprises since the introduction of automated systems into the cockpits of advanced technology aircraft. Pilot errors have actually been induced by automated systems, especially when the pilot doesn't fully understand what the automated systems are doing during all modes of operation. In order to structure the research program for investigating these problems, the National Aeronautics and Space Administration (NASA) has developed a framework for human-centered automation. This framework is described in the NASA document Human-Centered Aircraft Automation Philosophy by Charles Billings. It is the thesis of this paper that a corresponding framework of human-centered automation should be developed for the nuclear industry. Such a framework would serve to guide the design and regulation of automated systems for advanced reactor designs, and would help prevent some of the problems that have arisen in other applications that have followed a ''technology-centered'' approach

  4. Analysis of public perception about impaired odor in center fishery processing industry Tegalsari Tegal city

    Science.gov (United States)

    Wibowo, Tri Setyo; Purwanto, P.; Yulianto, Bambang

    2017-03-01

    The Coastal Fishing Port (CFP) Tegalsari is one of the largest center of the fishery industries in Central Java Indonesia. In addition to producing fish-based products such as fish fillets, salted fish and fish meal are distributed to most major cities in Indonesia, but also generate waste and wastewater which potentially disrupt the environment. The purpose of this study describe the perception of the public about the negative impact of the activities in center fishery processing industry. The research method uses qualitative research design with the population living around the center of the fishing industry, with samples taken by purposive sampling numbered 30 people and 3 location sample to know concentration of ammoniac and hydrogen Sulfide. Data research in 2016 was processed using statistical methods. The results of research showed very significant, 80% of respondents who said the fishing activities causing nuisance odor. The remaining 20% stated that the odor nuisance almost imperceptibly. The nuisance of odor are perceived by 53% of respondents for a full day. There are 70% of respondents living around the center of the fishing industry who lived more than seven years, and the remaining 30% of respondents who lived less than 7 years. Conclusion respondent who live more than seven years and said there was no odor nuisance around 57%, are more than 50% of the respondents. The odor of the most influential parameter on the fishing industry is an element of ammoniac (NH3) instead of Hydrogen Sulfide (H2S), because the value at these three locations for Hydrogen Sulfide measurement results show the same number that is equal to 0.001 g/m3. While ammoniac levels at most locations smelled according to perceptions of examiners showed the highest scores, while the zone that did not feel the smell indicates a low value, the test results showed a clear level of distinction. So the need to manage the environment at the center of the fishing industry with a approach of

  5. Computed radiography- the state of the art

    International Nuclear Information System (INIS)

    Marinho, Carla Alves; Rabello, Jose Mauricio; Aiub, Marcos; Iguchi, Eduardo; Lopes, Ricardo; Oliveira, Davi de

    2007-01-01

    Despite the advantages obtained with the radiographic inspection, the risks inherent to the exposure of ionizing radiations not always represented the major limiters regarding the employment of the technique. However, with the arrival of the computed radiography, the industrial radiology gets space again due to the benefits provided by the new technology, among which the following are outstanding: possibility of reduction of the time of radiography exposure and, consequently, of the marking area, direct acquisition of images, reduction of consumables and chemical waste and possibility of using again the detectors (imaging plates). Before such a favorable scenario, the computed radiography is being highlighted as the solution for almost all the problems, even without the full knowledge of its advantages and restrictions. This work briefly presents the state of the art related with the industrial applications (in-service inspection of wall loss and weld inspection) and the limitations noticed up to the moment are discussed. (author)

  6. A program of industrial consultation by a community mental health center.

    Science.gov (United States)

    Lepkin, M

    1975-01-01

    A staff member of a community mental health center provided consultation services to untrained industrial counselors at a large private corporation. Characteristics of "newer' workers, ethnically different from supervisors, are described. Attitude change is the key, but difficult to bring about. The consultant had full cooperation of the counselors, but never gained full support from management. The article describes procedures for training counselors and successful and unsuccessful efforts to reach foremen.

  7. First optical education center in Japan established by cooperation between academia and industry

    Science.gov (United States)

    Yatagai, Toyohiko

    2014-07-01

    At the present of the 21st century, optical technology became what must be in our life. If there is no optical technology, we cannot use optical equipments such as the camera, microscopes, DVD, LEDs and laser diodes (LDs). Optics is also the leading part in the most advanced scientific field. It is clear that the organization which does education and research is required in such a very important area. Unfortunately, there was no such organization in Japan. The education and research of light have been individually done in various faculties of universities, various research institutes, and many companies. However, our country is now placed in severer surroundings, such as the globalization of our living, the accelerated competition in research and development. This is one of the reasons why Utsunomiya University has established Center for Optical Research and Education (CORE) in 2007. To contribute to optical technology and further development of optical industry, "Center for Optical Research and Education (CORE), Utsunomiya University" promotes education and research in the field of the optical science and technology cooperatively with industry, academia and the government. Currently, 6 full professors, 21 cooperative professors, 2 visiting professors and 7 post-doctoral researchers and about 40 students are joined with CORE. Many research projects with industries, the local government of Tochigi as well as Japanese government. Optical Innovation Center has established in CORE by supporting of Japan Science and Technology Agency in 2011 to develop advanced optical technologies for local companies.

  8. New prospect in neutron radiography

    International Nuclear Information System (INIS)

    Cluzeau, S.

    1991-01-01

    Neutron radiography is a very useful non-destructive testing (NDT) method which frequently complements classical X-ray inspection. Numerous inspections in some fields are currently performed at reactor-based neutron radiography facilities but many other interesting applications in different fields are at present not considered because the objects to be tested cannot be moved to a reactor. It is the goal of the DIANE project, to allow the utilization of this NDT method in industrial facilities by developing a safe and convenient neutron radiography equipment using an ''on-off'' neutron source. As a result of the efforts of the four European partners, a first laboratory demonstration model is currently in operation in Germany and a fully mobile second one is expected by the end of 1992. Good radiographs are obtained with exposure times in the range of a few seconds to ten minutes using an electronic imaging system. The fast neutron generator uses a sealed neutron tube delivering 5.10 11 neutrons.cm -2 .s -1 in 4 π steradian; with a collimator ratio of about 12, the fluence rate onto the object is then close to 1,5.10 5 thermal neutrons.cm -2 .s -1 . (author)

  9. Radiography - A conceptual approach

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari

    2008-01-01

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline

  10. Adaptation of a Control Center Development Environment for Industrial Process Control

    Science.gov (United States)

    Killough, Ronnie L.; Malik, James M.

    1994-01-01

    In the control center, raw telemetry data is received for storage, display, and analysis. This raw data must be combined and manipulated in various ways by mathematical computations to facilitate analysis, provide diversified fault detection mechanisms, and enhance display readability. A development tool called the Graphical Computation Builder (GCB) has been implemented which provides flight controllers with the capability to implement computations for use in the control center. The GCB provides a language that contains both general programming constructs and language elements specifically tailored for the control center environment. The GCB concept allows staff who are not skilled in computer programming to author and maintain computer programs. The GCB user is isolated from the details of external subsystem interfaces and has access to high-level functions such as matrix operators, trigonometric functions, and unit conversion macros. The GCB provides a high level of feedback during computation development that improves upon the often cryptic errors produced by computer language compilers. An equivalent need can be identified in the industrial data acquisition and process control domain: that of an integrated graphical development tool tailored to the application to hide the operating system, computer language, and data acquisition interface details. The GCB features a modular design which makes it suitable for technology transfer without significant rework. Control center-specific language elements can be replaced by elements specific to industrial process control.

  11. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years......Background: Chest radiography is one of the most common examinations in radiology departments. In 2013 approximately 80,000 chest x-rays were performed on women in the fertile age. Even low dose for the examinationCorrect collimation Purpose: Quality improvement of basic radiography focusing...... of age are included in the study. The clinical research is performed between September and November 2014 where 3rd year Radiography students collect data on four Danish x-ray departments using identical procedures under guidance of clinical supervisors. Optimal collimation is determined by European...

  12. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Vejle-Sørensen, Jens Kristian; Thomsen, Henrik

    Purpose: Quality improvement of basic radiography focusing on collimation and dose reduction in digital chest radiography Methods and Materials:A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from...... one hundred fifty self-reliant female patients between 15 and 55 years of age are included in the study. The clinical research is performed between September and November 2014 where 3rd year Radiography students collect data on four Danish x-ray departments using identical procedures under guidance...... at the conference. Conclusion: Collimation improvement in basic chest radiography can reduce the radiation to female patients at chest x-ray examinations....

  13. Exploiting the return on experience of incidents in the field of industrial radiography; L'exploitation du retour d'experience des incidents dans le domaine de la radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    Bataille, C.; Crouail, P. [Centre d' Etude sur I' Evaluation de la Protection dans le domaine Nucleaire (CEPN), 28 rue de la Redoute, 92260 Fontenay-aux-Roses (France); Gauron, C. [Institut National de Recherche et de Securite (INRS), 30 rue Olivier Noyer, 75014 Paris (France); Abela, G. [EDF, DIN DQSNR, 1 Place Pleyel, 93282 St Denis Cedex (France); Martin, E. [COFREND, 1 rue Gaston Boissier, 75724 PARIS Cedex 15 (France)

    2008-07-01

    After a presentation of the RELIR network (a French system of return on experience on radiological incidents), the aim of which is to collect typical incidents in different activity sectors (industry, medicine, veterinary, research, teaching, transports) in order to report them during professional training sessions, the authors briefly present some new files which have been recently produced. They deal with incidents due to a failing marking-out, intentional marking overstepping during non destructive testing, incomplete evacuation of the exclusion zone during non destructive testing and irradiation of an operator during a gamma-graphic shot, incident during a training session

  14. Radiography Following Perinatal Death: A Review

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, Oe.E. [Great Ormond Street Hospital for Children NHS Trust, London (United Kingdom). Radiology Dept.

    2006-02-15

    Radiography of the perinatally dead infant provides detailed information about the skeleton and is valuable as an adjunct to autopsy. This article reviews the potential benefits and discusses the pitfalls in assessment of growth stage. Reference charts for individual bone lengths and secondary ossification centers are presented.

  15. Recent developments in radiography

    International Nuclear Information System (INIS)

    Berger, Harold

    1982-01-01

    Advances in radiography are reviewed and eighty-one references are cited to provide additional information. The review includes information on x-ray sources in terms of output, portability and imaging geometry and detectors in terms of films and screens, electrostatic methods, real-time techniques and solid state devices. Inspection methods utilizing radiations other than x-rays, neutrons and charged particles, expand the inspection problems suitable for radiography. Techniques such as tomography, digital radiography and image enhancement are described. Tomography, in particular, provides excellent capability to characterize materials and discontinuities

  16. Transitioning to digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, F., E-mail: Francisco.Miranda@pwc.ca [Pratt & Whitney Canada, Longueuil, Quebec (Canada)

    2015-09-15

    This article provides insight on the technical and business considerations necessary to implement or to transition to digital radiography Continued refinements in digital radiography technology have resulted in significant improvements in image quality and detectability of indications. These improvements have resulted in the acceptance of the technology by users and aerospace primes for final product inspection and disposition. Digital radiography has also been identified as an interesting cost reduction initiative with the potential of providing gains in productivity through increased throughput and decreased inspection lead-times and resulting costs. (author)

  17. KBTAC: EPRI's center to assist the nuclear industry to apply the knowledge-based technology

    International Nuclear Information System (INIS)

    Lin, Chinglu; Naser, J.A.; Sun, B.K.H.

    1993-01-01

    The nuclear utility industry's complex engineering and procedure systems offer many opportunities for use of the knowledge-based technology such as expert systems and neural networks. The ability of expert systems to enhance human experts makes them an important tool in the areas of engineering, operations and maintenance. However, many current industry applications are research projects or turnkey systems supplied by vendors. These often do not impart to utility technical staff a clear understanding of the capabilities of knowledge-based systems (KBS). More importantly, simply using completed applications does not meet utilities' need to acquire the capabilities to build their own knowledge-based systems. Thus, EPRI is supporting its member utilities utilization of knowledge-based technology for power plant engineering, operations, and maintenance applications through the establishment of the Knowledge-Based Technology Application Center (KBTAC)

  18. A Virtual Geophysical Network: Using Industry Standard Technology to Link Geographically Distributed Sensors and Data Centers

    Science.gov (United States)

    Ahern, T. K.; Benson, R. B.; Crotwell, H. P.

    2003-12-01

    The IRIS Data Management System has long supported distributed data centers as a method of providing scientific researchers access to data from seismological networks around the world. For nearly a decade, the NetDC system used email as the method through which users could access data centers located around the globe in a seamless fashion. More recently the IRIS DMC has partnered with the University of South Carolina to develop a new method through which a virtual data center can be created. The Common Object Request Broker Architecture (CORBA) technology is an industry standard distributed computing architecture. Traditionally used by major corporations, IRIS has developed a Data Handling Interface (DHI) system that is capable of connecting services at participating data centers (servers) to applications running on end-users computing platforms (clients). For seismology we have identified three services. 1) A network service that provides information about geophysical observatories around the world such as where the sensors exist, what types of information are recorded on the sensors, and calibration information that allows proper use of the data, 2) an event service that allows applications to access information about earthquakes and seismological events and 3) waveform services that allow users to gain access to seismograms or time series data from other geophysical sensors. Seismological Data Centers operate the servers thereby allowing a variety of client applications to directly access the information at these data centers. Currently IRIS, the U. of South Carolina, UC Berkeley, and a European Data Center (ORFEUS) have been involved in the DHI project. This talk will highlight some of the DHI enabled clients that allow geophysical information to be directly transferred to the clients. Since the data center servers appear with the same interface specification (Interface Definition Language) a client that can talk to one DHI server can talk to any DHI enabled

  19. Which technologies to replace gamma radiography?

    International Nuclear Information System (INIS)

    Zani-Demange, M.L.; Chauveau, D.

    2012-01-01

    Gamma radiography with iridium source is largely used in the industrial sector for the control of welds, tubes and pressure vessels as well as for monitoring corrosion. Hazards due to the handling of ionizing radiation sources (Ir 192 ) and constraints due to a more and more demanding regulations call for alternative methods. The French 'Institut de soudure' has led a 4-year long study (Alter-X project) and has identified 3 alternative methods for the iridium gamma radiography: -) the TOFD (Time Of Flight Diffraction) which is based on the analysis of the diffraction of ultrasound waves on the edges of defects; -) phased array ultrasound which is based on a series of elementary sensors that can be handled in an individual manner by specific electronics, the sweeping is no more manual but electronic and enables the operator to localize and size defects deep under the surface; -) digit radiography that is a common radiography in which the film is replaced by a re-usable phosphorus screen that is more sensitive and can be easily digitalized and has no need for a chemical treatment to be read. Digit radiography used with Se 75 (another gamma emitter) gives comparable or even better results than with Ir 192 but with a dose rate cut by half at least. (A.C.)

  20. Experiments on neutron radiography

    International Nuclear Information System (INIS)

    Abdul Ghaffar Ramli; Azali Muhamad; Wan Ruslan Yusof; Ahmad Sabri Abdul Razak; Jamal Khaer Ibrahim; Rosley Jaafar

    1984-01-01

    This paper presents the neutron-radiography research activities in Nuclear Energy Unit (UTN) as a trial before a neutron-radiography service can routinely be given. This trial neutron-radiography research encompasses the design and construction of a facility (NuR 1), collimator and the exposure system, as well as measurements of neutron and gamma dose-distribution, neutron-beam properties in NuR 1 and characteristics of the image recorder. A few problems arose in the early stage of work and the action taken to overcome these are also mentioned. Finally, methods of increasing the quality of the image are proposed and attempted. This project has given some important information so as to enable the construction of a permanent facility (Nur 2) and the execution of a neutron-radiography service. (author)

  1. High energy neutron radiography

    International Nuclear Information System (INIS)

    Gavron, A.; Morley, K.; Morris, C.; Seestrom, S.; Ullmann, J.; Yates, G.; Zumbro, J.

    1996-01-01

    High-energy spallation neutron sources are now being considered in the US and elsewhere as a replacement for neutron beams produced by reactors. High-energy and high intensity neutron beams, produced by unmoderated spallation sources, open potential new vistas of neutron radiography. The authors discuss the basic advantages and disadvantages of high-energy neutron radiography, and consider some experimental results obtained at the Weapons Neutron Research (WNR) facility at Los Alamos

  2. 76 FR 81511 - Draft Guidance for Industry and Food and Drug Administration Staff; Center for Devices and...

    Science.gov (United States)

    2011-12-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-D-0893] Draft Guidance for Industry and Food and Drug Administration Staff; Center for Devices and Radiological... appropriate, and other forms of information technology. Draft Guidance for Industry and Food and Drug...

  3. Defense, basic, and industrial research at the Los Alamos Neutron Science Center: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Longshore, A.; Salgado, K. [comps.

    1995-10-01

    The Workshop on Defense, Basic, and Industrial Research at the Los Alamos Neutron Science Center gathered scientists from Department of Energy national laboratories, other federal institutions, universities, and industry to discuss the use of neutrons in science-based stockpile stewardship, The workshop began with presentations by government officials, senior representatives from the three weapons laboratories, and scientific opinion leaders. Workshop participants then met in breakout sessions on the following topics: materials science and engineering; polymers, complex fluids, and biomaterials; fundamental neutron physics; applied nuclear physics; condensed matter physics and chemistry; and nuclear weapons research. They concluded that neutrons can play an essential role in science-based stockpile stewardship and that there is overlap and synergy between defense and other uses of neutrons in basic, applied, and industrial research from which defense and civilian research can benefit. This proceedings is a collection of talks and papers from the plenary, technical, and breakout session presentations. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  4. Threats to the Sustainability of the Outsourced Call Center Industry in the Philippines: Implications for Language Policy

    Science.gov (United States)

    Friginal, Eric

    2009-01-01

    This study overviews current threats to the sustainability of the outsourced call center industry in the Philippines and discusses implications for macro and micro language policies given the use of English in this cross-cultural interactional context. This study also summarizes the present state of outsourced call centers in the Philippines, and…

  5. Selection of melter systems for the DOE/Industrial Center for Waste Vitrification Research

    International Nuclear Information System (INIS)

    Bickford, D.F.

    1993-01-01

    The EPA has designated vitrification as the best developed available technology for immobilization of High-Level Nuclear Waste. In a recent federal facilities compliance agreement between the EPA, the State of Washington, and the DOE, the DOE agreed to vitrify all of the Low Level Radioactive Waste resulting from processing of High Level Radioactive Waste stored at the Hanford Site. This is expected to result in the requirement of 100 ton per day Low Level Radioactive Waste melters. Thus, there is increased need for the rapid adaptation of commercial melter equipment to DOE's needs. DOE has needed a facility where commercial pilot scale equipment could be operated on surrogate (non-radioactive) simulations of typical DOE waste streams. The DOE/Industry Center for Vitrification Research (Center) was established in 1992 at the Clemson University Department of Environmental Systems Engineering, Clemson, SC, to address that need. This report discusses some of the characteristics of the melter types selected for installation of the Center. An overall objective of the Center has been to provide the broadest possible treatment capability with the minimum number of melter units. Thus, units have been sought which have broad potential application, and which had construction characteristics which would allow their adaptation to various waste compositions, and various operating conditions, including extreme variations in throughput, and widely differing radiological control requirements. The report discusses waste types suitable for vitrification; technical requirements for the application of vitrification to low level mixed wastes; available melters and systems; and selection of melter systems. An annotated bibliography is included

  6. Selection of melter systems for the DOE/Industrial Center for Waste Vitrification Research

    Energy Technology Data Exchange (ETDEWEB)

    Bickford, D.F.

    1993-12-31

    The EPA has designated vitrification as the best developed available technology for immobilization of High-Level Nuclear Waste. In a recent federal facilities compliance agreement between the EPA, the State of Washington, and the DOE, the DOE agreed to vitrify all of the Low Level Radioactive Waste resulting from processing of High Level Radioactive Waste stored at the Hanford Site. This is expected to result in the requirement of 100 ton per day Low Level Radioactive Waste melters. Thus, there is increased need for the rapid adaptation of commercial melter equipment to DOE`s needs. DOE has needed a facility where commercial pilot scale equipment could be operated on surrogate (non-radioactive) simulations of typical DOE waste streams. The DOE/Industry Center for Vitrification Research (Center) was established in 1992 at the Clemson University Department of Environmental Systems Engineering, Clemson, SC, to address that need. This report discusses some of the characteristics of the melter types selected for installation of the Center. An overall objective of the Center has been to provide the broadest possible treatment capability with the minimum number of melter units. Thus, units have been sought which have broad potential application, and which had construction characteristics which would allow their adaptation to various waste compositions, and various operating conditions, including extreme variations in throughput, and widely differing radiological control requirements. The report discusses waste types suitable for vitrification; technical requirements for the application of vitrification to low level mixed wastes; available melters and systems; and selection of melter systems. An annotated bibliography is included.

  7. IBM Industry Practice: Challenges in Offshore Software Development from a Global Delivery Center

    Science.gov (United States)

    Musio, Ilario

    Offshore software development has greatly influenced competitiveness among IT companies in the last decade. Despite the fact that there are matured and developed offshoring methodologies, there is an ongoing tendency to look for new ways of improving them. Major IT corporations successfully rely on their offshore delivery centers for bridging the gap between communication and infrastructure boundaries. However, projects tend to fail, so problems have to be considered that arise between on- and offshore parts within the same corporation. Based on seven case studies from the industry, this paper describes experiences and challenges faced during the execution of offshore application development between IBM Switzerland and IBM India. Additionally, approaches on how they can be solved are proposed.

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  9. Digital radiography in NDT applications

    International Nuclear Information System (INIS)

    Deprins, E.

    2004-01-01

    A lot of film radiography could be replaced by today's technologies in the field of digital radiography. Only few of these applications have indeed replaced film. The choice to go digital depends on cost, quality requirement, workflow and throughput. Digital images offer a lot of advantages in terms of image manipulation and workflow. But despite the many advantages, a lot of considerations are needed before someone can decide to convert his organization from conventional to digital radiography. This paper gives an overview of all different modalities that can be used in digital radiography with today's technologies, together with the experiences of the pioneers of digital radiography. Film Scanning, Computed Radiography and Digital Radiography by using of different kinds of flat panel detectors all have their specific application fields and customers. What is the status of the technology today, which advantages brings digital radiography, and which are the limitations radiographers have to consider when replacing film by digital systems. (author)

  10. Dynamic neutron radiography instrumentation and applications in Central Europe

    International Nuclear Information System (INIS)

    Balasko, M.

    1996-01-01

    Characteristic features of simultaneous dynamic neutron and gamma radiography installations built in the last ten years at the Budapest/Hungary and at the Seibersdorf/Austria research reactors are surveyed. For image detection scintillation detectors and a low-light level television camera with video output are used, thereby providing the possibility for visualizing medium speed movements inside the investigated object. The radiography stations have been used for inspecting industrial products, with the aim of research and development. (orig.)

  11. Spatially coded backscatter radiography

    International Nuclear Information System (INIS)

    Thangavelu, S.; Hussein, E.M.A.

    2007-01-01

    Conventional radiography requires access to two opposite sides of an object, which makes it unsuitable for the inspection of extended and/or thick structures (airframes, bridges, floors etc.). Backscatter imaging can overcome this problem, but the indications obtained are difficult to interpret. This paper applies the coded aperture technique to gamma-ray backscatter-radiography in order to enhance the detectability of flaws. This spatial coding method involves the positioning of a mask with closed and open holes to selectively permit or block the passage of radiation. The obtained coded-aperture indications are then mathematically decoded to detect the presence of anomalies. Indications obtained from Monte Carlo calculations were utilized in this work to simulate radiation scattering measurements. These simulated measurements were used to investigate the applicability of this technique to the detection of flaws by backscatter radiography

  12. Are radiography lecturers, leaders?

    International Nuclear Information System (INIS)

    Hendry, Julie Anne

    2013-01-01

    This review article aims to explore the concept of radiography lecturers acting as leaders to their student followers. Through a brief review of the literature, a definition of leadership is suggested and some leadership theories explored. The path-goal theory, leader–member exchange theory and the contemporary theory of transformational leadership are examined more closely. Links between lecturer-leader behaviour and student motivation and learning are tentatively suggested with transformational leadership appearing to offer the optimal leadership style for lecturers to adopt. The paucity of literature relating directly to radiography is acknowledged and areas for further research are suggested. The article concludes with some of the author's practical ideas for incorporating transformational leadership styles and behaviours into radiography education today

  13. Broadening the radiography spectrum

    International Nuclear Information System (INIS)

    Waswa, L.; Mutwasi, O.; Kioko, J.

    2006-05-01

    The text discuses the mammography in breast screening and evaluation of breast cancer; Small parts ultrasounds at plaza imaging solutions; role of a Radiographer in mammography-new perspective; Medical imaging education in africa; Caring for the paediatric patient as to broaden radiotherapy spectrum; Problems and challenges in care for children undergoing radiotherapy; Paediatric radiotherapy, management and side effects; The principles of pattern recognition of skeletal structures; the place of distance learning education in broadening the radiography spectrum; the curriculum and budgeting image; sonographer's guide; Computed radiography- X-Ray with vision; digital Radiography in Kenya today; Particle Therapy at Ithemba Labs; The role of lung perfusion and ventilation study in the evaluation of the pulmonary embolism and lastly, an overview of Head and neck treatment at Kenyatta National hospital radiotherapy

  14. Real-time radiography

    International Nuclear Information System (INIS)

    Bossi, R.H.; Oien, C.T.

    1981-01-01

    Real-time radiography is used for imaging both dynamic events and static objects. Fluorescent screens play an important role in converting radiation to light, which is then observed directly or intensified and detected. The radiographic parameters for real-time radiography are similar to conventional film radiography with special emphasis on statistics and magnification. Direct-viewing fluoroscopy uses the human eye as a detector of fluorescent screen light or the light from an intensifier. Remote-viewing systems replace the human observer with a television camera. The remote-viewing systems have many advantages over the direct-viewing conditions such as safety, image enhancement, and the capability to produce permanent records. This report reviews real-time imaging system parameters and components

  15. Practical radiography. 11. ed.

    International Nuclear Information System (INIS)

    Hoxter, E.A.

    1982-01-01

    After a brief explanation of the basics of electricity, the fundamentals of radiography are dealt with in more detail - the discovery of X-rays, their nature and properties, the production of the X-ray image and ways of improving the image. A chapter is devoted to the important subject of radiation protection. Explanations are given of the use of the Siemens exposure tables, which make it simpler to modify exposures from the values given in the tables. There is also a section on some of the standard radiographic positioning for patients. The most common medical terms used in radiography and fluoroscopy are listed and an Appendix gives details of the major items of Siemens X-ray equipment. There is a list of literature recommended for further study. Theoretical explanations have been kept to a minimum so that information that is important to radiography can be emphasized. (orig./MG)

  16. Consumption of industrialized food by infants attending child day care centers

    Directory of Open Access Journals (Sweden)

    Maysa Helena de A. Toloni

    2014-03-01

    Full Text Available Objective: To identify the age of introduction of petit suisse cheese and instant noodles in the diet of infants attending nurseries of public day care centers and to compare the nutritional composition of these foods with the healthy recommended diet (breast milk and salt meal for this age, in order to estimate nutritional errors. Methods: Cross-sectional study of 366 children (from nine to 36 months old who attended day care centers, whose mothers were interviewed about the age of introduction of those foods. The means of the nutrients indicated on the labels of the most consumed brands were considered. For the calculation of the percent composition of breast milk and salt meal, Tables of Food Composition were used. To assess the nutritional adequacy, we used the Dietary Reference Intakes by age group. The percentage of adequacy evaluation of the petit suisse cheese and the instant noodles nutritional compositions was made by comparing them with those of the human milk and the salt meal, respectively. Results: The petit suisse cheese and the instant noodles were consumed by 89.6 and 65.3% of the children in the first year of life. The percentages of adequacy for carbohydrates were more than twice and the percentages for sodium were 20 times higher than those found in the recommended foods. Conclusions: Both industrialized products are inappropriate for infants, emphasizing the need for adoption of norms that can inform health professionals, educators and parents about the risks of consumption.

  17. Consumption of industrialized food by infants attending child day care centers.

    Science.gov (United States)

    Toloni, Maysa Helena de A; Longo-Silva, Giovana; Konstantyner, Tulio; Taddei, José Augusto de A C

    2014-03-01

    To identify the age of introduction of petit suisse cheese and instant noodles in the diet of infants attending nurseries of public day care centers and to compare the nutritional composition of these foods with the healthy recommended diet (breast milk and salt meal) for this age, in order to estimate nutritional errors. Cross-sectional study of 366 children (from nine to 36 months old) who attended day care centers, whose mothers were interviewed about the age of introduction of those foods. The means of the nutrients indicated on the labels of the most consumed brands were considered. For the calculation of the percent composition of breast milk and salt meal, Tables of Food Composition were used. To assess the nutritional adequacy, we used the Dietary Reference Intakes by age group. The percentage of adequacy evaluation of the petit suisse cheese and the instant noodles nutritional compositions was made by comparing them with those of the human milk and the salt meal, respectively. The petit suisse cheese and the instant noodles were consumed by 89.6 and 65.3% of the children in the first year of life. The percentages of adequacy for carbohydrates were more than twice and the percentages for sodium were 20 times higher than those found in the recommended foods. Both industrialized products are inappropriate for infants, emphasizing the need for adoption of norms that can inform health professionals, educators and parents about the risks of consumption.

  18. Industrial gamma radiography on a building site with a portable device. Recommendations to operators - gammagraphy sheet ED 4243; Recommendations to intervening companies (subcontractors) -gammagraphy sheet ED 4244; Recommendations to user companies - gammagraphy sheet ED 4245

    International Nuclear Information System (INIS)

    Vaisseau, Bernard; Bourdon, Patrick; Laurent, Pierre; Servent, Jean-Pierre; Biau, Alain

    2006-12-01

    Based on best practices, three sheets indicate sets of recommendations regarding the use of an industrial gamma radiography portable device on a building site either by operators, intervening companies (or subcontractors), or user companies. As far as operators are concerned, recommendations concern preparation and transport, arrival on the building site, examination performance, end of examination, occurrence of an incident other than radiological, and occurrence of a radiological incident. As far as subcontractors are concerned, recommendations concern the actors of the intervening company, the permanent storage site of portable devices, the film development laboratory, portable devices and their accessories, other equipment used for examination, vehicles, operators, intervention preparation, the return on experience, and the immediate processing of anomalies. As far as user companies are concerned, recommendations concern actors of the user company, the definition of the operation, the previous inspection of premises and the definition of a prevention plan, the storage of equipment containing depleted uranium, loading and unloading operations, the coordination of exposure doses, the immediate processing of anomalies, and the return on experience. Moreover, the three sheets indicate the associated legal texts

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  1. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  4. Evaluation of Technological Trends and Demands of the Manufacturing Industry to a Center of R&D&I

    Directory of Open Access Journals (Sweden)

    Leone Peter Correia da Silva Andrade

    2015-10-01

    Full Text Available The manufacturing industry is fairly representative in the Brazilian economy. The research activities in technology, development and innovation promoted by technology centers are of great importance to boost the competitiveness of this segment. In this context, this work aims presenting the development of the strategic planning for a Center of R&D&I (Research & Development & Innovation, looking 20 years ahead, on a macro level, creating a master plan which summarizes the future focus areas of competence for technology research, development and innovation, coping with manufacturing trends, using a participative workshop approach. Thus, it is expected that this center offer integrated technological solutions with high added value that promote the development and competitiveness of the manufacturing industry, in the prospects for medium and long term. In order to achieve the project objectives taking the principle of strategic planning was followed. On the one hand, focus was placed on the internal perspective analyzing the current status of the Center. On the other hand, the environment of the Center (external perspective was analyzed. Matching the analysis results regarding both perspectives future competence areas were derived, according to global technological trends as well as national and local industrial demand. Thus, the competencies required to be developed by a technology center to meet the manufacturing industry over the next twenty years would be derived.

  5. Chest X ray effective doses estimation in computed radiography

    International Nuclear Information System (INIS)

    Abdalla, Esra Abdalrhman Dfaalla

    2013-06-01

    Conventional chest radiography is technically difficult because of wide in tissue attenuations in the chest and limitations of screen-film systems. Computed radiography (CR) offers a different approach utilizing a photostimulable phosphor. photostimulable phosphors overcome some image quality limitations of chest imaging. The objective of this study was to estimate the effective dose in computed radiography at three hospitals in Khartoum. This study has been conducted in radiography departments in three centres Advanced Diagnostic Center, Nilain Diagnostic Center, Modern Diagnostic Center. The entrance surface dose (ESD) measurement was conducted for quality control of x-ray machines and survey of operators experimental techniques. The ESDs were measured by UNFORS dosimeter and mathematical equations to estimate patient doses during chest X rays. A total of 120 patients were examined in three centres, among them 62 were males and 58 were females. The overall mean and range of patient dosed was 0.073±0.037 (0.014-0.16) mGy per procedure while the effective dose was 3.4±01.7 (0.6-7.0) mSv per procedure. This study compared radiation doses to patients radiographic examinations of chest using computed radiology. The radiation dose was measured in three centres in Khartoum- Sudan. The results of the measured effective dose showed that the dose in chest radiography was lower in computed radiography compared to previous studies.(Author)

  6. Neutron radiography at the Paul Scherrer Institute

    International Nuclear Information System (INIS)

    Pleinert, H.; Lehmann, E.; Hammer, J.

    1994-01-01

    Neutron radiography provides an efficient tool of measurement for many applications in fundamental research as well as in industrial non-destructive testing (NDT). A neutron radiography program has been initiated at the Paul Scherrer Institute and implemented since 1992. From the beginning of 1992 until the end of 1993, a neutron facility has been in operation at the SAPHIR research reactor. Several applications have been tested and programs on two main fields of application have been established, focusing on the study of porous materials, especially concrete and granitic rock. The investigations on concrete and other building materials are carried out in cooperation with the Swiss Federal Institute of Technology in Zurich. The experimental activities are currently carried out at the Atominstitute of the Austrian Universities in Vienna, in the framework of a cooperation program with the Atominstitute. The continuation of the activities on a new radiography facility at the spallation source SINQ is planned at the Paul Scherrer Institute. In the following an overview of the method, of the actual and potential applications of neutron radiography at the Paul Scherrer Institute is given. (author) 6 figs., 1 tab., 3 refs

  7. A Collection-Distribution Center Location and Allocation Optimization Model in Closed-Loop Supply Chain for Chinese Beer Industry

    OpenAIRE

    Kai Kang; Xiaoyu Wang; Yanfang Ma

    2017-01-01

    Recycling waste products is an environmental-friendly activity that can result in manufacturing cost saving and economic efficiency improving. In the beer industry, recycling bottles can reduce manufacturing cost and the industry’s carbon footprint. This paper presents a model for a collection-distribution center location and allocation problem in a closed-loop supply chain for the beer industry under a fuzzy random environment, in which the objectives are to minimize total costs and transpor...

  8. A Selection Model to Logistic Centers Based on TOPSIS and MCGP Methods: The Case of Airline Industry

    Directory of Open Access Journals (Sweden)

    Kou-Huang Chen

    2014-01-01

    Full Text Available The location selection of a logistics center is a crucial decision relating to cost and benefit analysis in airline industry. However, it is difficult to be solved because there are many conflicting and multiple objectives in location problems. To solve the problem, this paper integrates fuzzy technique for order preference by similarity to an ideal solution (TOPSIS and multichoice goal programming (MCGP to obtain an appropriate logistics center from many alternative locations for airline industry. The proposed method in this paper will offer the decision makers (DMs to set multiple aspiration levels for the decision criteria. A numerical example of application is also presented.

  9. Scanning equalization radiography

    International Nuclear Information System (INIS)

    Plewes, D.B.

    1992-01-01

    The invention is in the field of radiography and seeks to reduce the undesirable effects on a radiographic image due to variations in thickness of the irradiated object which cause large variations in exposure at the image plane that can exceed the practical or desirable exposure range of the film or other imaging medium. 17 figs

  10. Neutron induced electron radiography

    International Nuclear Information System (INIS)

    Andrade, Marcos Leandro Garcia

    2008-01-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 μm in 24 μm of aluminum at a resolution of 32 μm. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  11. Lessons Learned Through the Follow-up of the Long-Term Effects of Over-Exposure to an Ir192 Industrial Radiography Source in Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Jalil, A.; Rabbani, G.; Hossain, M. K.; Alam, M. K.; Koddus, A.

    2003-02-24

    An industrial radiographer was accidentally over-exposed while taking the radiograph of weld-joints of gas pipe-lines in 1985 in Bangladesh. Symptoms of high radiation exposure occurred immediately after the accident and skin erythema developed leading to progressive tissue deterioration. The consequences of this over-exposure is being followed up to assess the long-term effects of ionizing radiation on the victim. Progressive tissue deteriorations have already led to multiple surgeries and successive amputations of the finger-tips so far. Lessons learned from this accident are also reported in this paper.

  12. Comparison of Neutron Radiography With Other Nondestructive Methods

    Science.gov (United States)

    Balasko, M.; Svab, E.; Endroczy, G.

    2005-02-01

    The development and quality insurance of high tech products of industry needs the application of various nondestructive testing methods. We have applied neutron-, gamma-, and X-ray radiography, vibration diagnostics, acoustic emission, and neutron diffraction for testing various industrial products. Here, we present some of our recent results obtained on absorption-type refrigerators, on automotive Visco clutches and on high temperature thermostats.

  13. Dose control in semi industrial irradiation plant at the Ezeiza Atomic Center

    International Nuclear Information System (INIS)

    Dorda, E.M.

    1987-01-01

    In 1975 a study was initiated at the Division of Dosimetry to develop a technique and a system of dosimetry to be applied to the radiosterilization processes in the semi industrial irradiation plant of Ezeiza Atomic Center. The result of this study was the potassium nitrate/nitrite dosimeter used as routine dosimeter for control processes in food conservation, with a dose range of 0.2 kGy-1 kGy and in radiosterilization processes of disposable medical products of 1 kGy-150kGy. The potassium nitrate crystals undergo a radiolytic reduction. A linear correlation between the dose applied to the solid and the production of potassium nitrite was observed. After the irradiation of solid, the produced nitrite solution is colorimetrically titrated by measuring the absorbency in a spectrophotometer at 504 nm. The color is due to the formation of a diazonium salt and its later copulation with N-1 naphtylethylendiamine hydrochloride in acid medium. In 1980 a postal survey was organized presenting this dosimeter to standardize the irradiation dose in industrial process for Latin America. This dosimeter was presented in 1984 at the International Symposium on High Doses of the IAEA that took place in Vienna. Since them, comparative studies were performed between this dosimeter and those internationally considered and accepted: cerium(IV)/cerium(III) sulphate, ionization chamber of parallel plates, alanine. The results of comparison with the alanine dosimeter, which was used by Dr. Regula of the GSF of Munich, were the following: February 1985: 0% deviation; February 1986: 0.43% deviation. (Author)

  14. Artifacts in digital radiography

    International Nuclear Information System (INIS)

    Min, Jung Whan; Kim, Jung Min; Jeong, Hoi Woun

    2015-01-01

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments

  15. Artifacts in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Whan [Dept. of Radiological Technology, Shin Gu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Technology, Korea University, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Beakseok Culture University, Cheonan (Korea, Republic of)

    2015-12-15

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

  16. 78 FR 24380 - National Sheep Industry Improvement Center: Notice of Request for Extension and Revision of a...

    Science.gov (United States)

    2013-04-25

    ...; ] DEPARTMENT OF AGRICULTURE Agricultural Marketing Service National Sheep Industry Improvement Center: Notice...: Agricultural Marketing Service, USDA. ACTION: Notice and request for comments. SUMMARY: In accordance with the... Promotion Division; Livestock, Poultry, and Seed Program; Agricultural Marketing Service; U.S. Department of...

  17. Dose in conventional radiography

    International Nuclear Information System (INIS)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, however due to the workload in a radiology service individual dose is not monitored. In order to evaluate the dose due to chest radiography in this work a plate phantom was built according to the ISO recommendations using methylmethacrylate walls and water. The phantom was used in the Imaging department of the Zacatecas General Hospital as a radiology patient asking for a chest study; using thermoluminescent dosimeters, TLD 100 the kerma at the surface entrance was determined. (Author)

  18. Heavy-ion radiography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Holley, W.R.; Benton, E.V.

    1981-01-01

    Heavy-particle radiography has clinical potential as a newly developed noninvasive low-dose imaging procedure that provides increased resolution of minute density differences in soft tissues of the body. The method utilizes accelerated high-energy ions, primarily carbon and neon, at the Bevalac accelerator at the Lawrence Berkeley Laboratory. The research program for medicine utilizes heavy-ion radiography for low-dose mammography, for treatment planning for cancer patients, and for imaging and accurate densitometry of skeletal structures, brain and spinal neoplasms, and the heart. The potential of heavy-ion imaging, and particularly reconstruction tomography, is now proving to be an adjunct to existing diagnostic imaging procedures in medicine, both for applications to the diagnosis, management and treatment of clinical cancer in man, and for the early detection of small soft-tissue tumors at low radiation dose

  19. Research possibilities of modern neutron radiography and its application for material testing

    International Nuclear Information System (INIS)

    Czachor, A.; Mikke, K.

    1995-01-01

    The physical base of neutron radiography methods has been performed and explained. Their application as measurement methods in fundamental investigations as well as in material testing in industry and for examination of machines and other big objects has been shown. Perspectives of a further development of neutron radiography methods have been also discussed. 49 refs, 36 figs, 4 tabs

  20. Electronic imaging system for neutron radiography at a low power research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, F.J.O., E-mail: fferreira@ien.gov.b [Instituto de Engenharia Nuclear, Comissao Nacional de Energia Nuclear, Caixa Postal 68550, CEP 21945-970, Rio de Janeiro (Brazil); Silva, A.X.; Crispim, V.R. [PEN/COPPE-DNC/POLI CT, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970 Rio de Janeiro (Brazil)

    2010-08-15

    This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

  1. Radiography in endodontics.

    Science.gov (United States)

    Bridgman, J B; Campbell, D J

    1995-06-01

    In endodontics, the paralleling technique has a geometrical advantage over the bisecting angle technique and results in radiographs with less distortion. Distortion is undesirable for endodontic radiography as it can significantly alter the apparent position of an endodontic instrument relative to the root apex. However, there are instances where the bisecting angle is preferable, and consideration should be given to this technique to improve the image quality when it is used.

  2. Panoramic dental radiography

    International Nuclear Information System (INIS)

    Cushman, R.H.; Kircher, D.R.; Hart, F.W.; Ciavattoni, A.

    1980-01-01

    Apparatus is described for improving the handling rate of patients in panoramic dental radiography when tube head-camera assembly of a low silhouette panoramic dental X-ray machine is rotated for a scan in one direction only. This is effected by fast return of the tube head-camera assembly with its simultaneous elevation, thus facilitating the radiographed patient's exit from the machine and the entrance of another patient. Fast speed is about twice the scanning speed. (author)

  3. An overview of digital radiography

    International Nuclear Information System (INIS)

    Aweligiba, S. A.

    2013-04-01

    The medical application of radiography has gained wider study since diagnostic radiology plays a very important role in modern medicine for fast diagnosis and therapy. Digital radiography is a relatively new technology that promises greater accuracy, lesser dose and better manipulation of patient radiology images in hospitals. In this study, a general discussion on digital radiography has been presented. The presentation focuses on the optimisation of doses to patients in the medical application of digital radiography, quality control and quality assurance. A brief presentation on performance indicators in digital radiography has also been presented. The advantages of digital radiography over the conventional film/screen system have been elaborated and its limitations are also outlined. (author)

  4. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  5. A Comparison of Lens-Coupled Area Detector DR to Conventional Radiography

    International Nuclear Information System (INIS)

    Poland, R.W.

    2001-01-01

    Savannah River Technology Center filmless radiographic imaging system specialists have been ''champions'' of filmless radiographic imaging at the Savannah River Site since 1993. Recently a study was done comparing the differences between conventional film radiography and lens-coupled, charge-coupled-device digital radiography. Characteristics of both imaging methods that were considered in the study included resolution, latitude (called dynamic range by digital radiography imaging specialists), and modulation transfer functions. The results of those comparative experiments will be presented. A description of the lens-coupled, digital radiography imaging system will be provided

  6. A WEB-BASED FRAMEWORK FOR VISUALIZING INDUSTRIAL SPATIOTEMPORAL DISTRIBUTION USING STANDARD DEVIATIONAL ELLIPSE AND SHIFTING ROUTES OF GRAVITY CENTERS

    Directory of Open Access Journals (Sweden)

    Y. Song

    2017-09-01

    Full Text Available Analysing spatiotemporal distribution patterns and its dynamics of different industries can help us learn the macro-level developing trends of those industries, and in turn provides references for industrial spatial planning. However, the analysis process is challenging task which requires an easy-to-understand information presentation mechanism and a powerful computational technology to support the visual analytics of big data on the fly. Due to this reason, this research proposes a web-based framework to enable such a visual analytics requirement. The framework uses standard deviational ellipse (SDE and shifting route of gravity centers to show the spatial distribution and yearly developing trends of different enterprise types according to their industry categories. The calculation of gravity centers and ellipses is paralleled using Apache Spark to accelerate the processing. In the experiments, we use the enterprise registration dataset in Mainland China from year 1960 to 2015 that contains fine-grain location information (i.e., coordinates of each individual enterprise to demonstrate the feasibility of this framework. The experiment result shows that the developed visual analytics method is helpful to understand the multi-level patterns and developing trends of different industries in China. Moreover, the proposed framework can be used to analyse any nature and social spatiotemporal point process with large data volume, such as crime and disease.

  7. a Web-Based Framework for Visualizing Industrial Spatiotemporal Distribution Using Standard Deviational Ellipse and Shifting Routes of Gravity Centers

    Science.gov (United States)

    Song, Y.; Gui, Z.; Wu, H.; Wei, Y.

    2017-09-01

    Analysing spatiotemporal distribution patterns and its dynamics of different industries can help us learn the macro-level developing trends of those industries, and in turn provides references for industrial spatial planning. However, the analysis process is challenging task which requires an easy-to-understand information presentation mechanism and a powerful computational technology to support the visual analytics of big data on the fly. Due to this reason, this research proposes a web-based framework to enable such a visual analytics requirement. The framework uses standard deviational ellipse (SDE) and shifting route of gravity centers to show the spatial distribution and yearly developing trends of different enterprise types according to their industry categories. The calculation of gravity centers and ellipses is paralleled using Apache Spark to accelerate the processing. In the experiments, we use the enterprise registration dataset in Mainland China from year 1960 to 2015 that contains fine-grain location information (i.e., coordinates of each individual enterprise) to demonstrate the feasibility of this framework. The experiment result shows that the developed visual analytics method is helpful to understand the multi-level patterns and developing trends of different industries in China. Moreover, the proposed framework can be used to analyse any nature and social spatiotemporal point process with large data volume, such as crime and disease.

  8. Revisited the mathematical derivation wall thickness measurement of pipe for radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hamzah, A.R.; Amir, S.M.M. [Non Destructive Testing(NDT) Group, Industrial Technology Div., Malaysian Nuclear Agency, Selangor (Malaysia)

    2007-07-01

    Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical principles. In order to derive the maximum penetration wall thickness a similar approach is used. (authors)

  9. Mass chest radiography in Greece

    International Nuclear Information System (INIS)

    Papavasiliou, C.

    1987-01-01

    In Greece mass chest radiography has been performed regularly on various population groups as a measure to control tuberculosis. Routine chest radiography is performed in most Greek hospitals on admission. In this report available data-admittedly inadequate-directly or indirectly addressing the problem of benefit versus the risk or cost associated with this examination is presented

  10. Student Incivility in Radiography Education.

    Science.gov (United States)

    Clark, Kevin R

    2017-07-01

    To examine student incivility in radiography classrooms by exploring the prevalence of uncivil behaviors along with the classroom management strategies educators use to manage and prevent classroom disruptions. A survey was designed to collect data on the severity and frequency of uncivil student behaviors, classroom management strategies used to address minor and major behavioral issues, and techniques to prevent student incivility. The participants were educators in radiography programs accredited by the Joint Review Committee on Education in Radiologic Technology. Findings indicated that severe uncivil student behaviors in radiography classrooms do not occur as often as behaviors classified as less severe. Radiography educators in this study used a variety of strategies and techniques to manage and prevent student incivility; however, radiography educators who received formal training in classroom management reported fewer incidents of student incivility than those who had not received formal training. The participants in this study took a proactive approach to addressing severe behavioral issues in the classroom. Many radiography educators transition from the clinical environment to the classroom setting with little to no formal training in classroom management. Radiography educators are encouraged to attend formal training sessions to learn how to manage the higher education classroom effectively. Student incivility is present in radiography classrooms. This study provides a foundation for future research on incivility. ©2017 American Society of Radiologic Technologists.

  11. Model-centered approach to early planning and design of an eco-industrial park around an oil refinery.

    Science.gov (United States)

    Zhang, Xiangping; Strømman, Anders H; Solli, Christian; Hertwich, Edgar G

    2008-07-01

    Industrial symbiosis promises environmental and economic gains through a utilization of the waste of some processes as a resource for other processes. Because of the costs and difficulties of transporting some wastes, the largest theoretical potential for industrial symbiosis is given when facilities are colocated in an eco-industrial park (EIP). This study proposes a model-centered approach with an eight-step procedure for the early planning and design of an eco-industrial park considering technical and environmental factors. Chemical process simulation software was used to model the energy and material flows among the prospective members and to quantify the benefits of integration among different firms in terms of energy and resources saved as compared to a reference situation. Process simulation was based on a combination of physical models of industrial processes and empirical models. The modeling allows for the development and evaluation of different collaboration opportunities and configurations. It also enables testing chosen configurations under hypothetical situations or external conditions. We present a case study around an existing oil and gas refinery in Mongstad, Norway. We used the approach to propose the colocation of a number of industrial facilities around the refinery, focused on integrating energy use among the facilities. An EIP with six main members was designed and simulated, matching new hypothetical members in size to the existing operations, modeling material and energy flows in the EIP, and assessing these in terms of carbon and hydrogen flows.

  12. Radiography with polarised neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael L.

    2010-08-20

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni{sub 3}Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T{sub C} on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with

  13. Computed radiography - our experience

    International Nuclear Information System (INIS)

    Williams, C.

    1997-01-01

    Computed Radiography (CR) is the digital acquisition of plain X-ray images using phosphor plate technology. This allows post- processing and transmission of images to remote locations. St. Vincent's Public Hospital in Melbourne has had the benefit of two separate CR systems which have been implemented over the past three years. CR is a significant advance in radiographic imaging and is evolving continuously. The last few years have been a period of change and development for all staff which has proved both challenging and rewarding. Further development is required before the system is implemented completely. (author)

  14. Radiography with polarised neutrons

    International Nuclear Information System (INIS)

    Schulz, Michael L.

    2010-01-01

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd 1-x Ni x and Ni 3 Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd 1-x Ni x and Ni 3 Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni 3 Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T C on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with different ordering temperatures. This

  15. People Centered Innovation: Enabling Lean Integrated Project Delivery and Disrupting the Construction Industry for a More Sustainable Future

    Directory of Open Access Journals (Sweden)

    William Paolillo

    2016-01-01

    Full Text Available People-centered innovation is a paradigm shift in the construction industry. It is derived from the supposition that people not methods, schedules, or budgets deliver projects. Our data suggest that a multilevel, multidisciplinary project team through shared vision, values, and a common vernacular defines, designs, and delivers more successful projects than traditional methods. These projects meet the needs of shareholders, the community, stakeholders, and the planet. We employ the concepts of emotional intelligence and agency theory to explain an integrated project delivery (IPD construction project using lean tactics that not only delivered, but also exceeded expectations resulting in a six-month schedule acceleration and $60M savings over the original estimated cost of the project calculated assuming traditional project delivery methods. The safety rating for this project was 50% better than the national average and the expected improvement in operating margin for the new building is 33% greater. This paper introduces the notion of people-centered innovation to an industry that has struggled to adapt and show positive results over recent decades. Our case study describes the significance of people-centered innovation in construction project delivery. We discuss the implications for the construction industry going forward.

  16. Digital radiography of the chest

    International Nuclear Information System (INIS)

    Sakurai, Kenji; Hachiya, Junichi; Korenaga, Tateo; Nitatori, Toshiaki; Miyasaka, Yasuo; Furuya, Yoshiro

    1984-01-01

    Initial clinical experience in digital chest radiography utilizing photostimulable phosphor and scanning laser stimulated luminescence was reported. Image quality of conventional film/screen radiography and digital radiography was compared in 30 normal cases. Reflecting wide dynamic range of the system, improved image quality was confirmed in all 30 cases, particularly in visibility of various mediastinal structures and pulmonary vessels. High sensor sensitivity of the system enabled digital radiography to reduce radiation dose requirement significantly. Diagnostically acceptable chest images were obtained with approximately 1/5 of routine dose for conventional radiography without significant image quality degradation. Some artifact created by digital processing were mostly overcome by a routine use of simultaneous display of two different types of image processing and therefore was not an actual drawback from diagnostic standpoint. Further technical advancement of the system to be seen for digital storage, retrieval and tranceference of images. (author)

  17. Development of Graduate Course Education by Industry Collaboration in Center for Engineering Education Development, CEED

    Science.gov (United States)

    Noguchi, Toru; Yoshikawa, Kozo; Nakamura, Masato; Kaneko, Katsuhiko

    New education programs for engineering graduate courses, and the achievements are described. Following the previous reports on overseas and domestic internship2) , 3) , this article states other common programs ; seminars on state of technologies in industries, practical English and internationalization programs, and a program to accept overseas internship students. E-learning system to assist off-campus students is also described. All these programs are developed and conducted by specialist professors invited from industries and national institutions, in collaboration with faculty professors. Students learn how the engineering science apply to the practical problems, acquire wider view and deeper understanding on industries, and gain abilities to act in global society including communication skill, those are not taught in classrooms and laboratories. Educational effects of these industry collaborated programs is significant to activate the graduate course education, although the comprehensive evaluation is the future subject.

  18. Medical radiography and information societies: Challenges and opportunities

    International Nuclear Information System (INIS)

    Kalra, H.P.S.

    2006-01-01

    This paper presents the perspective from a less developed country for broadening the horizon of medical imaging as an integral part of medical records and biomedical information. From the industrial to the information society, the number as well as the diversity of stakeholders in the medical records and medical information has grown. this call for a fresh outlook on medical radiography and medical imaging

  19. Quality assurance test of a real time radiography system

    International Nuclear Information System (INIS)

    Yadav, R.K.; Rama, R.; Sharma, A.; Kannan, R.

    2005-01-01

    Any radiation generating equipment can be used and marketed in India only after obtaining specific type approval certificate from the Competent Authority i.e. Chairman, Atomic Energy Regulatory Board (AERB), Mumbai. Recently AERB has enforced a directive that the Industrial X-ray machines should also be permitted to use only after getting NOC or type approval. Type approval is granted based upon the satisfactory QA test report of the radiation generating equipment. X-ray machines with Real Time Radiography (RTR) facility are used in industrial radiography for faster inspection of equipment's and products online. A standard test protocol was developed for QA tests of a real time radiography system. This will be helpful for evaluation of an industrial X-ray machine. Also above procedure can be used to check a RTR system each day or a system-qualification can be done when the image quality diminishes as recommended by American Society of Testing Material (ASTM). Various tests carried out on a constant potential 450 kV, 10 mA industrial X-ray machine having real time radiography facility to monitor the products online, is described in this paper. (author)

  20. Industrialization

    African Journals Online (AJOL)

    Lucy

    importantly exploiting cheap labour for industrial purposes from the native population. 13 . During the colonial era manufacturing in the continent was generally at the handicraft and small scale levels. In some colonies this was supplemented by some relatively complex industries producing mainly for export, but also ...

  1. Mobile real time radiography system

    International Nuclear Information System (INIS)

    Vigil, J.; Taggart, D.; Betts, S.

    1997-01-01

    A 450-keV Mobile Real Time Radiography (RTR) System was delivered to Los Alamos National Laboratory (LANL) in January 1996. It was purchased to inspect containers of radioactive waste produced at (LANL). Since its delivery it has been used to radiograph more than 600 drums of radioactive waste at various LANL sites. It has the capability of inspecting waste containers of various sizes from <1-gal. buckets up to standard waste boxes (SWB, dimensions 54.5 in. x 71 in. x 37 in.). It has three independent x-ray acquisition formats. The primary system used is a 12- in. image intensifier, the second is a 36-in. linear diode array (LDA) and the last is an open system. It is fully self contained with on board generator, HVAC, and a fire suppression system. It is on a 53-ft long x 8-ft. wide x 14-ft. high trailer that can be moved over any highway requiring only an easily obtainable overweight permit because it weights ∼38 tons. It was built to conform to industry standards for a cabinet system which does not require an exclusion zone. The fact that this unit is mobile has allowed us to operate where the waste is stored, rather than having to move the waste to a fixed facility

  2. Regional Rural Tourist Recreation Shopping Centers: A New Concept in the Leisure Industry

    Science.gov (United States)

    Nicholls, Leland L.

    1975-01-01

    A rural tourist-recreation shopping center is defined as an area relatively accessible to city dwellers that can be developed for recreation purposes. Twenty-three such areas have been identified in the Appalachian Highlands. (PS)

  3. Digital Radiography Qualification of Tube Welding

    Science.gov (United States)

    Carl, Chad

    2012-01-01

    The Orion Project will be directing Lockheed Martin to perform orbital arc welding on commodities metallic tubing as part of the Multi Purpose Crew Vehicle assembly and integration process in the Operations and Checkout High bay at Kennedy Space Center. The current method of nondestructive evaluation is utilizing traditional film based x-rays. Due to the high number of welds that are necessary to join the commodities tubing (approx 470), a more efficient and expeditious method of nondestructive evaluation is desired. Digital radiography will be qualified as part of a broader NNWG project scope.

  4. Experiments on muon radiography with emulsion track detectors

    International Nuclear Information System (INIS)

    Aleksandrov, Andrey; Bagulya, Alexander; Baklagin, Sergei; Chernyavsky, Mikhail; Galkin, Vladimir; Grachev, Victor; Konovalova, Nina; Managadze, Alexander; Polukhina, Natalya; Roganova, Tatiana; Starkov, Nikolai; Shchedrina, Tatiana; Tioukov, Valeri; Vladymirov, Mykhailo; Zemskova, Svetlana

    2016-01-01

    Muon radiography is a method of study the internal structure of large natural and industrial objects based on sensing an object with a flux of cosmic muons with their subsequent registration and analysis of the pattern of their dispersion, or conplete (or partial) absorption. The Lebedev Physical Institute of the Russian Academy of Sciences and the Skobeltsyn Institute of Nuclear Physics of Moscow State University have started a series of muon radiography experiments with nuclear emulsion detectors. As a result, the optimal conditions for experiment arrangement have been determined, algorithms of data processing have been worked out, and peculiarities of the method have been ultimately investigated

  5. National Composite Center-A new roof for composite industries in Malaysia

    Science.gov (United States)

    Abdullah, Abu; Yuhazri, M. Y.; Sulaiman, Mohd Yusoff

    2016-03-01

    Today's Malaysia has more than 70 companies that are actively involved in composite activities. The activities are ranging from various business sectors, using different technology and material. Composites has been used in a wide range of applications in Malaysia and contributes to growth in a diverse range of industry value chains from utilities through to boat building, manufacturing and industrial applications, aerospace, consumer products and construction products. Thus, a key part of this strategy is the establishment of the National Composites Centre (NCC), which will bring together dynamic companies and enterprising academics to develop new technologies for the design and rapid manufacture of high-quality composite products.

  6. Industrialization

    African Journals Online (AJOL)

    Lucy

    . African states as ... regarded as the most important ingredients that went to add value to land and labour in order for countries ... B. Sutcliffe Industry and Underdevelopment (Massachusetts Addison – Wesley Publishing Company. 1971), pp.

  7. Industrialization

    OpenAIRE

    Blundel, Richard

    2016-01-01

    Industrialization, the historical development that saw cheesemaking transformed from a largely craft-based or artisanal activity, often located on a dairy farm, to a production process that, for the most part, takes place in large ‘cheese factories’ or creameries [See ARTISANAL]. The principal features of modern industrialized cheesemaking, which set it apart from traditional approaches include: high production volumes; sourcing of milk from multiple dairy herds; pasteurization and re-balanci...

  8. Institutional dynamic of the call center industry in Denmark and France

    DEFF Research Database (Denmark)

    Sørensen, Ole H.; Beraud, Mathieu; Colin, Thierry

    2005-01-01

    The call centre development is substantially increasing in the most part of industrialized countries. Coming to the fore and seeking for staff, this sector is still looking for benchmarks, especially in terms of employment. Currently it can be said that the sector is under construction since its ...

  9. Improvements relating to radiography

    International Nuclear Information System (INIS)

    Bollen, R.H.; Vandenabeele, H.

    1977-01-01

    An improved combination of photosensitive materials suitable for use in radiography is described, with particular reference to a combination for an X-ray intensifying screen of the fluorescent type and a silver halide recorder. The intensifying material comprises a phosphor consisting wholly or mainly of a rare earth metal activated lanthanum oxyhalide, having more than half its spectral energy emission > 410 nm wavelength, more than half its visible light spectral energy emission in the range 400 to 500 nm, and its maximum energy emission peak in the range 400 to 450 nm. The phosphor should have a coverage of at least 200 to 800 g of the oxyhalide per sq. m. The screen material also contains a dye or pigment that absorbs light within the emission spectrum of the phosphor. The photosensitive recording material incorporates at least one silver halide emulsion layer. The combination should give a screen intensification factor of at least 20 to 40 kV. (U.K.)

  10. 15 CFR 291.4 - National industry-specific pollution prevention and environmental compliance resource centers.

    Science.gov (United States)

    2010-01-01

    ... the basis of the following criteria listed in descending order of importance: (1) Demonstrated.... Sources may include those internal to the Center (including staff expertise), but it is expected that many... recruitment, selection, training, and continuing professional development; and appropriateness of the...

  11. Industry

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, Lenny; Roy, Joyashree; Delhotal, K. Casey; Harnisch, Jochen; Matsuhashi, Ryuji; Price, Lynn; Tanaka, Kanako; Worrell, Ernst; Yamba, Francis; Fengqi, Zhou; de la Rue du Can, Stephane; Gielen, Dolf; Joosen, Suzanne; Konar, Manaswita; Matysek, Anna; Miner, Reid; Okazaki, Teruo; Sanders, Johan; Sheinbaum Parado, Claudia

    2007-12-01

    This chapter addresses past, ongoing, and short (to 2010) and medium-term (to 2030) future actions that can be taken to mitigate GHG emissions from the manufacturing and process industries. Globally, and in most countries, CO{sub 2} accounts for more than 90% of CO{sub 2}-eq GHG emissions from the industrial sector (Price et al., 2006; US EPA, 2006b). These CO{sub 2} emissions arise from three sources: (1) the use of fossil fuels for energy, either directly by industry for heat and power generation or indirectly in the generation of purchased electricity and steam; (2) non-energy uses of fossil fuels in chemical processing and metal smelting; and (3) non-fossil fuel sources, for example cement and lime manufacture. Industrial processes also emit other GHGs, e.g.: (1) Nitrous oxide (N{sub 2}O) is emitted as a byproduct of adipic acid, nitric acid and caprolactam production; (2) HFC-23 is emitted as a byproduct of HCFC-22 production, a refrigerant, and also used in fluoroplastics manufacture; (3) Perfluorocarbons (PFCs) are emitted as byproducts of aluminium smelting and in semiconductor manufacture; (4) Sulphur hexafluoride (SF{sub 6}) is emitted in the manufacture, use and, decommissioning of gas insulated electrical switchgear, during the production of flat screen panels and semiconductors, from magnesium die casting and other industrial applications; (5) Methane (CH{sub 4}) is emitted as a byproduct of some chemical processes; and (6) CH{sub 4} and N{sub 2}O can be emitted by food industry waste streams. Many GHG emission mitigation options have been developed for the industrial sector. They fall into three categories: operating procedures, sector-wide technologies and process-specific technologies. A sampling of these options is discussed in Sections 7.2-7.4. The short- and medium-term potential for and cost of all classes of options are discussed in Section 7.5, barriers to the application of these options are addressed in Section 7.6 and the implication of

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... to X-ray (Radiography) - Bone Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x- ... x-ray machine is a compact apparatus that can be taken to the patient in a hospital ...

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... will analyze the images and send a signed report to your primary care or referring physician , who ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose ... Medicine Radiation Safety How to Read Your Radiology Report Images related to X-ray (Radiography) - Bone Sponsored ...

  16. Proton Radiography (pRad)

    Data.gov (United States)

    Federal Laboratory Consortium — The proton radiography project has used 800 MeV protons provided by the LANSCE accelerator facility at LANL, to diagnose more than 300 dynamic experiments in support...

  17. Opinions of UK rescue shelter and rehoming center workers on the problems facing their industry

    OpenAIRE

    Stavisky, Jenny; Brennan, Marnie L.; Downes, Martin J.; Dean, Rachel S.

    2017-01-01

    Animal shelters exist worldwide to care for and rehome unwanted or straying pets. Previous studies have examined why owners breed unwanted animals, or relinquish their pets to shelters. However, the views of shelter workers, who receive and care for these animals, have previously been largely unexplored. The aim of this study was to investigate the perceptions of animal shelter workers on the problems facing their industry. A sampling frame was constructed, consisting of every identified shel...

  18. Industry

    OpenAIRE

    Schmidt-Belz, B.; Mohamad, Y.; Velasco, C.A.

    2009-01-01

    Industry plays a key role in the path towards eInclusion. While corporate social responsibility statements of leading companies confirm this, surveys show that there is still a long way to go. Among various reasons for the reluctant take-up of Design for All (DfA) by industry providing Information and Communication Technology (ICT), the lack of relevant knowledge and skills obviously plays a crucial role. Therefore, the DfA@eInclusion project has undertaken to develop curriculum guidelines an...

  19. Center for the Polyurethanes Industry summary of unpublished industrial hygiene studies related to the evaluation of emissions of spray polyurethane foam insulation.

    Science.gov (United States)

    Wood, Richard D

    2017-09-01

    Spray polyurethane foam (SPF) insulation is used as thermal insulation for residential and commercial buildings. It has many advantages over other forms insulation; however, concerns have been raised related to chemical emissions during and after application. The American Chemistry Council's (ACC's) Center for the Polyurethanes Industry (CPI) has gathered previously unpublished industrial hygiene air sampling studies submitted by member companies that were completed during an eight-year period from 2007-2014. These studies address emissions from medium density closed cell and low density open cell formulations. This article summarizes the results of personal and area air samples collected during application and post application of SPF to interior building surfaces in both laboratory and field environments. Chemicals of interest included: Volatile Organic Compounds (VOCs), methylene diphenyl diisocyanate (MDI), flame retardants, amine catalysts, blowing agents, and aldehydes. Overall, the results indicate that SPF applicators and workers in close proximity to the application are potentially exposed to MDI in excess of recommended and governmental occupational exposure limits and should use personal protective equipment (PPE) consisting of air supplied respirators and full-body protective clothing to reduce exposure. Catalyst emissions can be reduced by using reactive catalysts in SPF formulations, and mechanical ventilation is important in controlling emissions during and after application.

  20. A survey of digital radiography practice in four South African teaching hospitals: an illuminative study.

    Science.gov (United States)

    Nyathi, T; Chirwa, Tf; van der Merwe, Dg

    2010-01-01

    The purpose of this study was to assess radiographer familiarity and preferences with digital radiography in four teaching hospitals and thereafter make recommendations in line with the migration from screen film to digital radiography. A questionnaire was designed to collect data from either qualified or student radiographers from four teaching hospitals. From the four teaching hospitals, there were a total of 205 potential respondents. Among other things, responses regarding experiences and preferences with digital radiography, quality control procedures, patient dose, advantages and disadvantages of digital radiography were sought. The information collected was based on self-reporting by the participants. The study is exploratory in nature and descriptive statistics were generated from the collected data using Microsoft Excel 2007 and StatsDirect software. Sixty-three out of 205 (31%) radiographers from all the four radiology centers responded to the circulated questionnaire. Only 15% (8) of the qualified radiographers had 4 or more years of experience with digital radiography compared to 68% (36) for the same amount of experience with screen-film radiography. Sixty-one percent (38) of the participants had been exposed to digital radiography during their lectures while at university. A small proportion, 16% (10) of the respondents underwent formal training in quality control procedures on the digital X-ray units they were using. Slightly more than half (55%) of the participants felt it was easier for them to retake an image in digital radiography than in screen film radiography. The results of this survey showed that the participants are familiar with digital radiography and have embraced this relatively new technology as shown by the fact that they can identify both its advantages and disadvantages as applied to clinical practice. However, there are minimal quality control procedures specific to digital radiography being undertaken as such there is need for

  1. Radioisotopes in industry

    International Nuclear Information System (INIS)

    Popple, B.N.

    1977-01-01

    The author explains clearly what is radiography, enumerates four major factors in considering a practical source to use namely half-life, penetrating power, half value layer and specific activity and also the advantages and disadvantages in using isotopes. Common radioisotopes used in industrial radiography are iridium, cesium, cobalt and thulium. Main uses of the radioisotopes are for radiographic testing like welding castings, forgoings etc.; thickness, level or density measurement and tracing. (RTD)

  2. Texas Manufacturing Technology Center feasibility study for the Inland Regional Industrial Technology Institute

    International Nuclear Information System (INIS)

    1994-01-01

    This document presents the Texas Manufacturing Technology Center (TMTC) Business Plan to convert the Central Facility of the Superconducting Super Collider project to alternate uses. The plan is divided into six sections: (1) Executive Summary, (2) Market and Benefit Analysis, (3) Marketing Strategy, (4) Services, (5) Organization and Operations Overview, and (6) Financial Plan. Each area is supported by separate documents that address individual opportunities and challenges associated with transitioning the facility, and its asset base to new uses for benefit of the locality, state, region and nation

  3. Upper Gastrointestinal (GI) Tract X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Upper GI Tract Upper gastrointestinal tract radiography or ... X-ray? What is Upper Gastrointestinal (GI) Tract Radiography? Upper gastrointestinal tract radiography, also called an upper ...

  4. Operator-centered control of a semi-autonomous industrial robot

    Energy Technology Data Exchange (ETDEWEB)

    Spelt, P.F. [Oak Ridge National Lab., TN (United States); Jones, S.L. [REMOTEC, Inc., Oak Ridge, TN (United States)

    1994-12-31

    This paper presents work done by Oak Ridge National Laboratory and Remotec, Inc., to develop a new operator-centered control system for Remotec`s Andros telerobot. Andros robots are presently used by numerous electric utilities, the armed forces, and numerous law enforcement agencies to perform tasks which are hazardous for human operators. This project has automated task components and enhanced the video graphics display of the robot`s position in the environment to significantly reduce operator workload. The procedure of automating a telerobot requires the addition of computer power to the robot, along with a variety of sensors and encoders to provide information about the robots performance in and relationship to its environment The resulting vehicle serves as a platform for research on strategies to integrate automated tasks with those performed by a human operator. The addition of these capabilities will greatly enhance the safety and efficiency of performance in hazardous environments.

  5. Marketing strategy adjustments in the ambulatory care center industry: implications for community pharmacy.

    Science.gov (United States)

    Phillips, J H

    1989-01-01

    Each stage of a product's life cycle requires marketing strategy modifications in response to changing demand levels. The purpose of this study was to investigate changes in ambulatory care center (ACC) operational characteristics indicative of product, market, and distribution channel adjustments that could have a competitive impact upon community pharmacy practice. A questionnaire was mailed to a national sample of 325 ACC managers. Evidence of new product feature additions includes increased emphasis on continued care and increased prevalence of prescription drug dispensing. Expansion into new market segments and distribution channels was demonstrated by increased participation in HMO and employer relationships. The observed adjustments in ACC marketing strategies present obvious challenges as well as less obvious opportunities for community pharmacy practice.

  6. Operator-centered control of a semi-autonomous industrial robot

    International Nuclear Information System (INIS)

    Spelt, P.F.; Jones, S.L.

    1994-01-01

    This paper presents work done by Oak Ridge National Laboratory and Remotec, Inc., to develop a new operator-centered control system for Remotec's Andros telerobot. Andros robots are presently used by numerous electric utilities, the armed forces, and numerous law enforcement agencies to perform tasks which are hazardous for human operators. This project has automated task components and enhanced the video graphics display of the robot's position in the environment to significantly reduce operator workload. The procedure of automating a telerobot requires the addition of computer power to the robot, along with a variety of sensors and encoders to provide information about the robots performance in and relationship to its environment The resulting vehicle serves as a platform for research on strategies to integrate automated tasks with those performed by a human operator. The addition of these capabilities will greatly enhance the safety and efficiency of performance in hazardous environments

  7. Some applications of industrial neutrongraphy

    International Nuclear Information System (INIS)

    Joode, A.S.; Mury, A.G.O.S.

    1987-01-01

    The techniques used and main applications of neutrongraphy as non destructive inspection are presented. The advantages of this technique in relation to radiography and gamagraphy for using in industries are shown. (E.G.) [pt

  8. A study of neutron radiography

    International Nuclear Information System (INIS)

    Suksawang, P.

    1981-01-01

    The object of this study was to design and construct a neutron radiography device and investigate its capacity for detecting an internal structure of sample. Thai Research Reactor-1/Modification 1 was used as the neutron source and the thermal neutron flux for neutron radiography was 2.91 x 10 6 neutron-cm -2 -sec -1 . The direct technique was performed by using single intensifying screen of gadolinium (0.001 in) behind Kodak Industrex AA film and exposure time was about 100-150 sec. The neutron radiograph showed clearly the powder in the bullets. The indirect technique was also performed by using both indium (0.01 in) and dysprosium (0.001 in) as intensifying screen respectively and the neutron radiograph showed some details of the internal of Ir-192 source. In conclusion, any nuclear reactor equipped with probe tube and capable of operating at power greater than 1 k W may be useful for neutron radiography. In addition, neutron radiography has been shown to provide and imaging capability where X-radiography is not practical

  9. Digital Radiography in Kenya today

    International Nuclear Information System (INIS)

    Omenta, E.N.

    2006-01-01

    Its nearly one year and a half since digital imaging/radiography was introduced in Kenya mainly in Nairobi. the technology is becoming an increasingly effective and acceptable modality of producing radiographs from the traditional conventional radiography in use to date. the digital radiography offers numerous advantages that have been noted for the short period over the conventional way. For instance radiographs are produced in real time (less than 3 minutes), by so doing the technology has eliminated the wait for the processing period. the radiation exposure to the patient under the radiological examination is reduced as much as 90% from the traditional conventional film taking. The cost, labour and record-keeping necessary to maintain a chemical processor and darkroom operations are as well eliminated. The cost of purchasing and disposing of film wastes/darkroom processing chemicals, which are environmentally hazardous, also become unnecessary.digital radiography technology makes the digital images comparable to other images on the screen at that instant making both the patient and the clinician easily access images when needed. digital receptors have also replaced the cassette containing intensifying screens and film that is used in conventional radiography

  10. [Scientific and methodologic basis of a program for occupational control of ambient air quality within a totally sanitary protective zone at an industrial center borderline (Permsky area experience)].

    Science.gov (United States)

    Maĭ, I V; Balashov, S Iu

    2013-01-01

    The authors suggested and tested an algorithm to select optimal placement of stationary and mobile points for controlling ambient air quality on borderline of united sanitary protective zone of industrial center. The method involves claster analysis to outline sites even in levels and lists of parameters, on borderline of united sanitary protective zone of industrial center. Informative value of the occupational control parameters is evaluated through conjugated analysis of general level of surface concentration of admixtures and enterprise's contribution into pollution. For each enterprise, separate control program is provided. Tests of the method demonstrated that it is effective and conclusive in formation of minimally sufficient programs for occupational control in complicated conditions of industrial centers with single-field enterprises, when industrial releases are close in composition and in created pollution level.

  11. Neutron methods for industrial applications

    International Nuclear Information System (INIS)

    Glazkov, V.; Kvardakov, V.; Podurets, K.; Somenkov, V.; Shilstein, S.

    1999-01-01

    Complete text of publication follows. The results of industrial applications of various neutron methods (coherent and incoherent neutron scattering, absorption and refraction radiography, topography) are discussed. The main directions of the applied neutron program of Kurchatov Institute are the hydrogen detection in industrial materials at trace levels, visualization of defects in single crystal turbine blades, study of composite materials and steels with inhomogeneous magnetic and atomic structure, neutron focusing radiography and tomography. (author)

  12. Use of fluorescent screens for isotope radiography

    International Nuclear Information System (INIS)

    Hubbard, S.K.

    1979-01-01

    Radiographic examination can be performed on items beyond the limitation of conventional isotope radiography without a great loss of resolution. With proper film and screen selection and scatter radiation control, fluorescent screens can be a valuable additional tool for radiography

  13. Pediatric radiation dose management in digital radiography

    International Nuclear Information System (INIS)

    Neitzel, U.

    2004-01-01

    Direct digital radiography (DR) systems based on flat-panel detectors offer improved dose management in pediatric radiography. Integration of X-ray generation and detection in one computer-controlled system provides better control and monitoring

  14. Radiation protection for industrial radiography in the aerospace industry

    International Nuclear Information System (INIS)

    Morgan, W.E.

    1980-01-01

    An outline account is given of the general radiation protection policy of the Boeing Co.. Eighty radiographers are employed, operating ninety radiation sources, and taking 10,000 radiographic exposures per month. The radiographers average less than 100 milliRem whole body exposure per year. They have never been cited for governmental non-compliance, nor have had any radiation accidents. X-ray units, accelerators, and radioactive materials are used in the company radiographic inspection program on aircraft, missiles, and seacraft. The protection program is discussed under the following headings: hazard analysis, facility and equipment design, program administration, and evaluation of the protection system. (U.K.)

  15. Ecological and economical solutions for film radiography

    International Nuclear Information System (INIS)

    Marstboom, K.

    2004-01-01

    Film radiography may be perceived as technology with environmental concerns, involving the application of chemicals and the discharge of drained waters with high silver levels. Ecological legislation concerning silver content of the wash water differs from country to country. GE Inspection Technologies now offers industrial radiographers several ways to address regulatory limits silver in drained waters. First, two brand new film processors, the Agfa NDT Si and M eco, are introduced to the NDT market. Both machines are equipped with Cascade Fixing Technology, which reduces silver content in the wash water and increases the ability to comply with stricter discharge standards. Next the new eco Film System is presented. This system is based on the new machines, specially adapted films and carefully developed new chemicals. Eco stands for ecological and economic performance. The customer can now process films in a very short cycle, saving money while increasing its ability to comply with environmental limits on discharges of silver into drained waters. This paper will also address other means to reduce the silver freight in the wash water. Opportunities but most of all issues involved in the application of these technologies will be highlighted. Thus the presenter of this paper will demonstrate how film radiography responds to environmental concerns without causing extra financial burdens for the user. (author)

  16. Safety lock for radiography exposure device

    International Nuclear Information System (INIS)

    Gaines, T.M.

    1982-01-01

    A safety lock for securing a radiation source in a radiography exposure device is disclosed. The safety lock prevents the inadvertent extension of the radiation source from the exposure device. The exposure devices are used extensively in industry for nondestructive testing of metal materials for defect. Unnecessary exposure of the radiographer or operator occurs not infrequently due to operator's error in believing that the radiation source is secured in the exposure device when, in fact, it is not. The present invention solves this problem of unnecessary exposure by releasingly trapping the radiation source in the shield of the radiography exposure device each time the source is retracted therein so that it is not inadvertently extended therefrom without the operator resetting the safety lock, thereby releasing the radiation source. Further, the safety lock includes an indicator which indicates when the source is trapped in the exposure device and also when it is untrapped. The safety lock is so designed that it does not prevent the return of the source to the trapped, shielded position in the exposure device. Further the safety lock includes a key means for locking the radiation source in the trapped position. The key means cannot be actuated until said radiation source is in said trapped position to further insure the safety lock cannot be inadvertently locked with the source untrapped and thus still extendable from the exposure device

  17. Neutron radiography for nondestructive testing

    International Nuclear Information System (INIS)

    John, J.

    1979-01-01

    Neutron radiography is similar to X-ray inspection in that both depend upon use of radiation that penetrates some materials and is absorbed by others to provide a contrast image of conditions not readily available for visual inspection. X-rays are absorbed by dense materials, such as metals, whereas neutrons readily penetrate metals, but are absorbed by materials containing hydrogen. The neutron radiography has been successfully applied to a number of inspection situations. These include the inspection of explosives, advanced composites, adhesively bonded structures and a number of aircraft engine components. With the availability of Californium-252, it has become feasible to construct mobile neutron radiography systems suitable for field use. Such systems have been used for in-situ inspection of flight line aircraft, particularly to locate and measure hidden corrosion

  18. U.S. Department of Energy Regional Resource Centers Report: State of the Wind Industry in the Regions

    Energy Technology Data Exchange (ETDEWEB)

    Baranowski, Ruth [National Renewable Energy Lab. (NREL), Golden, CO (United St; Oteri, Frank [National Renewable Energy Lab. (NREL), Golden, CO (United St; Baring-Gould, Ian [National Renewable Energy Lab. (NREL), Golden, CO (United St; Tegen, Suzanne [National Renewable Energy Lab. (NREL), Golden, CO (United St

    2016-03-01

    The wind industry and the U.S. Department of Energy (DOE) are addressing technical challenges to increasing wind energy's contribution to the national grid (such as reducing turbine costs and increasing energy production and reliability), and they recognize that public acceptance issues can be challenges for wind energy deployment. Wind project development decisions are best made using unbiased information about the benefits and impacts of wind energy. In 2014, DOE established six wind Regional Resource Centers (RRCs) to provide information about wind energy, focusing on regional qualities. This document summarizes the status and drivers for U.S. wind energy development on regional and state levels. It is intended to be a companion to DOE's 2014 Distributed Wind Market Report, 2014 Wind Technologies Market Report, and 2014 Offshore Wind Market and Economic Analysis that provide assessments of the national wind markets for each of these technologies.

  19. A range of equipment for dental radiography

    International Nuclear Information System (INIS)

    Bergman, G.P.M.; Clement, S.L.

    1980-01-01

    A brief review of the history of dental radiography is followed by a description of the latest Philips equipment, ranging from compact units for intra-oral radiography to advanced systems for panoramic techniques and skull radiography. The advantages of automatic exposure control and automatic film processing are also discussed. In conclusion, some probable future trends are forecast. (Auth.)

  20. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very ... limitations of Chest Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the ...

  1. Neutron-induced alpha radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2008-01-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the α - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 μm in thickness can be inspected with a spatial resolution of 32 μm. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to β, γ, X-ray and visible light. (author)

  2. TREAT neutron-radiography facility

    International Nuclear Information System (INIS)

    Harrison, L.J.

    1981-01-01

    The TREAT reactor was built as a transient irradiation test reactor. By taking advantage of built-in system features, it was possible to add a neutron-radiography facility. This facility has been used over the years to radiograph a wide variety and large number of preirradiated fuel pins in many different configurations. Eight different specimen handling casks weighing up to 54.4 t (60 T) can be accommodated. Thermal, epithermal, and track-etch radiographs have been taken. Neutron-radiography service can be provided for specimens from other reactor facilities, and the capacity for storing preirradiated specimens also exists

  3. Planar channeling observed by radiography

    International Nuclear Information System (INIS)

    Delsarte, Guy

    1970-06-01

    Radiographies of crystals by means of channeled particles exhibit channeling patterns. The origin of these patterns is studied, The role played by planar channeling is demonstrated. It is shown that these patterns are local amplifications of the process generating the images of a crystal on the radiography. It is deduced that planar channeling plays a determining role in the formation of these images. An orientation chamber using transmitted planar channels is described. The orientation of very small grains in a polycrystal can be very easily obtained, (author) [fr

  4. Panoramic zonography in ear radiography

    International Nuclear Information System (INIS)

    Hallikainen, D.; Sjoeblom, C.J.; Toetterman, S.; Melartin, E.; Paukku, P.; Helsinki Univ. Central Hospital

    1983-01-01

    Thirty ears in 15 patients were examined by plain film radiography and by panoramic zonography with two tracks: A cylindrical concave image layer with 26 mm. radius and a paired sagittal image layer, at 51 mm. distance from midline. The films were interpreted according to the visibility of 23 different anatomic details. On panoramic films the visualization was better in 14 details, equal in 6 and worse in 3 compared to the plain films. The result suggests that panoramic techniques can replace conventional radiography of the ear. (orig.)

  5. Radiation protection in dental radiography

    International Nuclear Information System (INIS)

    Jozani, F.; Parnianpour, H.

    1976-08-01

    In considering the special provisions required in dental radiography, investigations were conducted in Iran. Radiation dose levels in dental radiography were found to be high. Patient exposure from intraoral radiographic examination was calculated, using 50kV X-ray. Thermoluminescent dosimeters were fastened to the nasion, eyes, lip, philtrum, thyroid, gonads and to the right and left of the supra-orbital, infra-orbital temporomandibular joints of live patients. The highest exposure value was for the lower lip. Recommendations concerning educational training and protection of staff and patients were included

  6. Mitigation of environmental impacts: a study of the companies that compose the Camaçari Industrial Center (PIC

    Directory of Open Access Journals (Sweden)

    Sonia Maria da Silva Gomes

    2016-09-01

    Full Text Available The purpose of this research was to map the environmental impacts of mitigation actions demonstrated in the sustainability reporting and financial statements of companies that compose the Camaçari Industrial Center (PIC from 2007 to 2013. Data from the Industrial Development Committee of Camaçari was used to survey the companies. The final sample consisted of 14 companies. Content analysis was used to identify the information contained in these reports, based on the model proposed by Nossa (2002 for measuring environmental impacts. The results showed that the subcategory most mentioned in the sustainability reports was wastefulness. It was found in 430 instances, followed by Recycling (157, CO² (129, Contamination and Land Restoration (122, and Conservation of Natural Resources (108. The wastefulness subcategory was also more present in the financial statements, with 77 instances, followed by Contamination and Land Restoration (49 and Recycling (29. There was also a growing trend of disclosure of environmental liabilities. The evidence indicates that the companies are concerned primarily with the treatment and disposal of their waste (solid, liquid and gaseous. The results are restricted to the period and sample investigated. Further research is suggested to broaden the sample and investigate the relationship between disclosure of environmental mitigation actions related to environmental impacts and the financial performance of companies. Additionally, studies could investigate which factors influence the adoption and dissemination of these actions, in the perception of managers of Brazilian companies.

  7. A Collection-Distribution Center Location and Allocation Optimization Model in Closed-Loop Supply Chain for Chinese Beer Industry

    Directory of Open Access Journals (Sweden)

    Kai Kang

    2017-01-01

    Full Text Available Recycling waste products is an environmental-friendly activity that can result in manufacturing cost saving and economic efficiency improving. In the beer industry, recycling bottles can reduce manufacturing cost and the industry’s carbon footprint. This paper presents a model for a collection-distribution center location and allocation problem in a closed-loop supply chain for the beer industry under a fuzzy random environment, in which the objectives are to minimize total costs and transportation pollution. Both random and fuzzy uncertainties, for which return rate and disposal rate are considered fuzzy random variables, are jointly handled in this paper to ensure a more practical problem solution. A heuristic algorithm based on priority-based global-local-neighbor particle swarm optimization (pb-glnPSO is applied to ensure reliable solutions for this NP-hard problem. A beer company case study is given to illustrate the application of the proposed model and to demonstrate the priority-based global-local-neighbor particle swarm optimization.

  8. NASA as a Convener: Government, Academic and Industry Collaborations Through the NASA Human Health and Performance Center

    Science.gov (United States)

    Davis, Jeffrey R.; Richard, Elizabeth E.

    2011-01-01

    On October 18, 2010, the NASA Human Health and Performance center (NHHPC) was opened to enable collaboration among government, academic and industry members. Membership rapidly grew to 60 members (http://nhhpc.nasa.gov ) and members began identifying collaborative projects as detailed below. In addition, a first workshop in open collaboration and innovation was conducted on January 19, 2011 by the NHHPC resulting in additional challenges and projects for further development. This first workshop was a result of the SLSD successes in running open innovation challenges over the past two years. In 2008, the NASA Johnson Space Center, Space Life Sciences Directorate (SLSD) began pilot projects in open innovation (crowd sourcing) to determine if these new internet-based platforms could indeed find solutions to difficult technical problems. From 2008 to 2010, the SLSD issued 34 challenges, 14 externally and 20 internally. The 14 external challenges were conducted through three different vendors: InnoCentive, Yet2.com and TopCoder. The 20 internal challenges were conducted using the InnoCentive platform, customized to NASA use, and promoted as NASA@Work. The results from the 34 challenges involved not only technical solutions that were reported previously at the 61st IAC, but also the formation of new collaborative relationships. For example, the TopCoder pilot was expanded by the NASA Space Operations Mission Directorate to the NASA Tournament Lab in collaboration with Harvard Business School and TopCoder. Building on these initial successes, the NHHPC workshop in January of 2011, and ongoing NHHPC member discussions, several important collaborations are in development: Space Act Agreement between NASA and GE for collaborative projects, NASA and academia for a Visual Impairment / Intracranial Hypertension summit (February 2011), NASA and the DoD through the Defense Venture Catalyst Initiative (DeVenCI) for a technical needs workshop (June 2011), NASA and the San Diego Zoo

  9. Visualization of multiphase flow by neutron radiography

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Takenaka, Nobuyuki.

    1991-01-01

    Neutron radiography (NRG) is a technique which produces images of the internal structure of a body, making use of the attenuation characteristics of neutrons in the materials being observed. Recently, attempts have been made to expand the application of this technique not only to non-destructive testing but also to a variety of industrial and basic research fields. The attenuation of neutrons is large in a light material like water and small in ordinary metals, which difference may make it possible to visualize a multiphase flow in a metallic container. Particularly, the neutron television, which is one of the applied techniques of NRG, is expected to be a useful tool for observing the behavior of two-phase flow, since it produces images in real time. In this paper the basic idea and the method of NRG are presented along with examples of visualization of multiphase flow by NRG. (author)

  10. Application of nomograms to calculate radiography parameters

    International Nuclear Information System (INIS)

    Voronin, S.A.; Orlov, K.P.; Petukhov, V.I.; Khomchenkov, Yu.F.; Meshalkin, I.A.; Grachev, A.V.; Akopov, V.'S.; Majorov, A.N.

    1979-01-01

    The method of calculation of radiography parameters with the help of nomograms usable for practical application under laboratory and industrial conditions, is proposed. Nomograms are developed for determining the following parameters: relative sensitivity, general non-definition of image, permissible difference of blackening density between the centre and edge of the picture (ΔD), picture contrast, focus distance, item thickness, radiation-physical parameter, dose build up factor, groove dimension and error. An experimental test has been carried out for evaluating the results, obtained with nomograms. Steel items from 25 to 79 mm thick have been subjected to testing 191 Ir has been used as a source. Comparison of calculation and experimental results has shown the discrepancy in sensitivity values, caused by ΔDsub(min) apriori index and the error, inherent in graphical plotting on a nomogram

  11. Utility of routine postoperative chest radiography in pediatric tracheostomy.

    Science.gov (United States)

    Genther, Dane J; Thorne, Marc C

    2010-12-01

    Routine chest radiography following pediatric tracheostomy is commonly performed in order to evaluate for air-tracking complications. Routine chest radiography affords disadvantages of radiation exposure and cost. The primary objective of this study was to determine the utility of routine postoperative chest radiography following tracheostomy in pediatric patients. Secondary objectives were to compare the rates of postoperative complications by various patient and surgeon characteristics. All infants and children 18 years of age or less (n=421) who underwent tracheostomy at a single tertiary-care medical center from January 2000 to April 2009 were included in the study. A combination of data obtained from billing and administrative systems and review of electronic medical records were recorded and compiled in a database for statistical analysis. Three air-tracking complications (2 pneumothoraces and 1 pneumomediastinum) were identified in our population of 421 pediatric patients, for an incidence of 0.71% (95% CI: 0.1-2.0%). No significant relationships were found between the incidence of air-tracking complication and surgical specialty, patient age, or type of procedure (elective, urgent/emergent). Our study identified a low rate of pneumothorax and pneumomediastinum following pediatric tracheostomy. In all three cases, the pneumothorax was suspected clinically. This finding suggests that postoperative chest radiography should be reserved for cases where there is suspicion of a complication on the basis of intraoperative findings or clinical parameters. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone ...

  13. Endobronchial Tuberculosis and Chest Radiography

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Sasani

    2016-03-01

    Full Text Available Endobronchial tuberculosis and chest radiography I read, with interest, the article entitled “Clinical and Para-clinical Presentations of Endobronchial Tuberculosis” by Ahmadi Hoseini H. S. et al. (1 published in this journal. I would like to focus on some details about the chest X-ray of patients as elaborated by the authors in the results section. Accordingly, the findings of chest radiography in the available patients were as follows: pulmonary consolidation (75%, reduced pulmonary volume (20%, and hilar adenopathy (10%. This is an incomplete statement because the authors did not explain whether there was any normal chest radiography in the study population. In addition, it is not clear whether the X-ray examinations of the patients were normal, how many abnormal plain films yielded the presented data. On the other hand, the fact that the studied patients had no normal chest radiography is  controversial since in the literature, 10-20% of the patients with endobronchial tuberculosis are reported to have normal chest X-ray (2, 3. In fact, this is one of the problems in the diagnosis of the disease, as well as a potential cause of delayed diagnosis and treatment of the patients. Therefore, the absence of normal chest radiographs is in contrast to the available literature, and if not an error, it could be a subject of further investigation.

  14. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very ... of an abdominal x-ray? What is abdominal x-ray? An x-ray (radiograph) is a noninvasive medical ...

  15. Developments in high resolution radiography

    International Nuclear Information System (INIS)

    Ridder, H.J.

    1976-01-01

    Critical aspects in the design of metal-ceramic X-ray tubes for high resolution radiography are presented. The performance of an X-ray system in which the focalspot can be varied from 0.5mm to 0.05mm is discussed as well as number of studies, which includes an assessment of the value of electronic image enhancement

  16. Polarized neutron radiography with a periscope

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael; Neubauer, Andreas; Muehlbauer, Martin; Schillinger, Burkhard; Pfleiderer, Christian; Boeni, Peter [Technische Universitaet Muenchen, Physik Department, E21, Garching (Germany); Calzada, Elbio, E-mail: michael.schulz@frm2.tum.d [Technische Universitaet Muenchen, Forschungsneutronenquelle Heinz Maier Leibnitz (FRM II), Garching (Germany)

    2010-01-01

    The interaction of the magnetic moment of the neutron with magnetic fields provides a powerful probe for spatially resolved magnetisation measurements in magnetic materials. We have tested a periscope as a new type of polarizer providing neutron beams with a high polarization and a low divergence. The observed inhomogeneity of the beam caused by the waviness of the glass substrates was quantified by means of Monte-Carlo simulations using the software package McStas. The results show that beams of high homogeneity can be produced if the waviness is reduced to below 1.0{center_dot}10{sup -5} rad. Finally, it is shown that radiography with polarized neutrons is a powerful method for measuring the spatially resolved magnetisation in optically float-zoned samples of the weak itinerant ferromagnet Ni{sub 3}Al, thereby aiding the identification of the appropriate growth parameters.

  17. Radiation-absorbed doses and energy imparted from panoramic tomography, cephalometric radiography, and occlusal film radiography in children

    International Nuclear Information System (INIS)

    Bankvall, G.; Hakansson, H.A.

    1982-01-01

    The absorbed doses and energy imparted from radiographic examinations of children, using panoramic tomography (PTG), cephalometric radiography (CPR), and maxillary frontal occlusal overview (FOO), were examined. The absorbed dose at various sites of the head were measured with TL dosimeters in a phantom and in patients. The energy imparted was calculated from measurements of areal exposure using a planparallel ionization chamber. The maximum absorbed doses for panoramic tomography were located around the lateral rotation center, for cephalometric radiography in the left (tube side) parotid region, and for frontal occlusal radiography in the nose. The absorbed doses in the eyes, thyroid gland, and skin are discussed and compared with previous reports and, for the most part, are found to be in agreement. The mean energy imparted from all three examination methods is 5 mJ with about 57 percent from panoramic, 33 percent from cephalometric, and 10 percent from frontal occlusal examinations. The energy imparted from cephalometric radiography can be reduced to about 10 percent with the use of an improved examination technique, leaving panoramic tomography responsible for contributing about 80 percent of the total energy imparted

  18. Examination of Industry Payments to Radiation Oncologists in 2014 Using the Centers for Medicare and Medicaid Services Open Payments Database.

    Science.gov (United States)

    Jairam, Vikram; Yu, James B

    2016-01-01

    To use the Centers for Medicare and Medicaid Services Open Payments database to characterize payments made to radiation oncologists and compare their payment profile with that of medical and surgical oncologists. The June 2015 release of the Open Payments database was accessed, containing all payments made to physicians in 2014. The general payments dataset was used for analysis. Data on payments made to medical, surgical, and radiation oncologists was obtained and compared. Within radiation oncology, data regarding payment category, sponsorship, and geographic distribution were identified. Basic statistics including mean, median, range, and sum were calculated by provider and by transaction. Among the 3 oncologic specialties, radiation oncology had the smallest proportion (58%) of compensated physicians and the lowest mean ($1620) and median ($112) payment per provider. Surgical oncology had the highest proportion (84%) of compensated physicians, whereas medical oncology had the highest mean ($6371) and median ($448) payment per physician. Within radiation oncology, nonconsulting services accounted for the most money to physicians ($1,042,556), whereas the majority of the sponsors were medical device companies (52%). Radiation oncologists in the West accepted the most money ($2,041,603) of any US Census region. Radiation oncologists in 2014 received a large number of payments from industry, although less than their medical or surgical counterparts. As the Open Payments database continues to be improved, it remains to be seen whether this information will be used by patients to inform choice of providers or by lawmakers to enact policy regulating physician-industry relationships. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. The application and development of radiography technology based on x-ray

    Science.gov (United States)

    Chen, Hao; Xu, Zhou; Li, Ming

    2009-07-01

    Modern Radiography technology was combined with radiation physics and modern imaging processing, which was an important branch of information obtainment and processing. We can get the inside information of the object, by the X ray's attenuation when the ray penetrated the object, and depending on the computer's fast processing, we can see the slice imaging of the object. Computerized Tomography, Computerized Laminography, and Digital Radiography were important parts in Radiography. The institute of applied electronics, CAEP in the research of intense radiation had developed several advanced radiation sources and some advanced radiography imaging systems, for example, S-band small spot linear accelerator, full solid state modulator, C-band linear accelerator, high energy Tera-hertz radiation source and CT technology based on cone beam, DR technology, CL Technology etc. Such imaging systems had been applied in industrial NDT/NDE, security check, medical diagnosis, petroleum and gas pipeline inspection system etc.

  20. Videoscopic assessment of the maintenance status of gamma radiography exposure containers employed in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Candeias, J P [IME, Military Institute of Engineering, Praca Gal Tiburcio 80, Praia Vermelha, Rio de Janeiro, 22290-270 (Brazil); Estrada, J J S [IME, Military Institute of Engineering, Praca Gal Tiburcio 80, Praia Vermelha, Rio de Janeiro, 22290-270 (Brazil); Pinho, A S [Institute of Radioprotection and Dosimetry (IRD/CNEN), Avenida Salvador Allende, PO Box 37750, Rio de Janeiro, 22780-160 (Brazil); D' Avila, R L [Institute of Radioprotection and Dosimetry (IRD/CNEN), Avenida Salvador Allende, PO Box 37750, Rio de Janeiro, 22780-160 (Brazil); Ramalho, A T [Institute of Radioprotection and Dosimetry (IRD/CNEN), Avenida Salvador Allende, PO Box 37750, Rio de Janeiro, 22780-160 (Brazil)

    2007-03-01

    Industrial radiography is the most frequent method of non-destructive testing (NDT) used by Brazilian industrial facilities for investigating the material integrity of a test object. In Brazil, industrial radiography employs around 220 x-ray and 290 gamma radiography machines. About 90% of the latter uses iridium ({sup 192}Ir) sources. The large majority of {sup 192}Ir projectors in operation in Brazil have been in continuous usage for more than 25 years, which means that they are old and worn-out. Usually the majority of accidents concerning gamma radiography occur during the return of the source into the exposure container. Poor maintenance or imperfections of the internal channel of the exposure container can lead to accidental source exposure. In the present work the internal tube of 65 gamma machines from nine Brazilian companies that render gamma radiography services were analysed using an industrial videoscope. The internal images from the projectors were compared with the internal image of an apparatus that had never been used, i.e. has never received a radioactive source. From the 65 machines evaluated, nine showed irregularities of the internal tube. It was also observed that each company follows a different methodology for the maintenance and lubrication of the exposure containers and drive cables.

  1. Proximal caries detection accuracy using intraoral bitewing radiography, extraoral bitewing radiography and panoramic radiography.

    Science.gov (United States)

    Kamburoglu, K; Kolsuz, E; Murat, S; Yüksel, S; Ozen, T

    2012-09-01

    To compare proximal caries detection using intraoral bitewing, extraoral bitewing and panoramic radiography. 80 extracted human premolar and molar teeth with and without proximal caries were used. Intraoral radiographs were taken with Kodak Insight film (Eastman Kodak Co., Rochester, NY) using the bitewing technique. Extraoral bitewing and panoramic images were obtained using a Planmeca Promax Digital Panoramic X-ray unit (Planmeca Inc., Helsinki, Finland). Images were evaluated by three observers twice. In total, 160 proximal surfaces were assessed. Intra- and interobserver kappa coefficients were calculated. Scores obtained from the three techniques were compared with the histological gold standard using receiver operating characteristic analysis. Az values for each image type, observer and reading were compared using z-tests, with a significance level of α = 0.05. Kappa coefficients ranged from 0.883 to 0.963 for the intraoral bitewing, from 0.715 to 0.893 for the extraoral bitewing, and from 0.659 to 0.884 for the panoramic radiography. Interobserver agreements for the first and second readings for the intraoral bitewing images were between 0.717 and 0.780, the extraoral bitewing readings were between 0.569 and 0.707, and the panoramic images were between 0.477 and 0.740. The Az values for both readings of all three observers were highest for the intraoral bitewing. Az values for the extraoral bitewing images were higher than those of the panoramic images without statistical significance (p > 0.05). Intraoral bitewing radiography was superior to extraoral bitewing and panoramic radiography in diagnosing proximal caries of premolar and molar teeth ex vivo. Similar intra- and interobserver coefficients were calculated for extraoral bitewing and panoramic radiography.

  2. Textile industry in Brno: A case study of cultural heritage and the memory of an industrial center (KULTURNÍ DĚDICTVÍ A PAMĚŤ INDUSTRIÁLNÍHO CENTRA (PŘÍPAD TEXTILNÍHO BRNA

    Directory of Open Access Journals (Sweden)

    Aleš Vyskočil

    2017-03-01

    Full Text Available This paper discusses industrial heritage, i.e. the society‘s relationship with the rem-nants of defunct industrial infrastructure. We demonstrate the issues involved on the example of Brno, one of the key economic centers of the Czech lands. Brno owes this status to its early industrialization, especially the textile industry which dominated its economic landscape from the late 1700s. Early 1990s saw the total collapse of the industry which resulted, inter alia, in the city‘s landscape being dotted by abandoned, defunct and derelict industrial buildings and building complexes. Those are now viewed as impediments to city‘s development and the city is looking for new ways to utilize them. These effort have been somewhat successful, for example in revitalizing a number of brownfields, but a large-scale solutions is still a desidera-tum. As a result, a number of building with great historical and cultural value have been torn down, including the industrial site of Vlněna, one of the icons of the textile industry in Brno, which was demolished in 2016. A unique opportunity to preserve, transform and revitalize this unique complex of buildings with immense historical value was wasted and thus a significant part of the industrial identity of Brno was irrevocably lost.

  3. Radioactive wastes storage rock porosity study using neutron radiography

    International Nuclear Information System (INIS)

    Peterka, F.

    1995-01-01

    Neutron radiography and neutron transmission analysis application to porosity study was mainly dealing with the building industry, the art protection and the basic research. Cooperation with the building industry has produced the solution of number of problems. Cement hydratation, concrete material, red brick sample, roofing tiles protection and epoxy resin efficiency for sand stones sculpture protection, can be cited as example. Many valuable experiences (like samples thickness, penetrating substances, detection techniques for the different experiments) were achieved. These can be used in the rockies formation studies too. Resolution is the proposal to JAERI and PNC for the cooperation, which can even be on the international basis. (J.P.N.)

  4. An industrial radiation source for food processing

    International Nuclear Information System (INIS)

    Sadat, R.

    1986-01-01

    The scientific linacs realized by CGR MeV in France have been installed in several research centers, the medical accelerators of CGR MeV have been installed in radiotherapy centers all over the world, and the industrial linacs have been used for radiography in heavy industries. Based on the experience for 30 years, CGR MeV has realized a new industrial radiation source for food processing. CARIC is going to install a new machine of CGR MeV, CASSITRON, as the demand for radiation increased. This machine has been devised specially for industrial irradiation purpose. Its main features are security, simplicity and reliability, and it is easy to incorporate it into a production line. The use of CASSITRON for food industry, the ionizing effect on mechanically separated poultry meat, the capital and processing cost and others are explained. Only 10 % of medical disposable supplies is treated by ionizing energy in France. The irradiation for food decontamination, and that for industrial treatment are demanded. Therefore, CARIC is going to increase the capacity by installing a CASSITRON for sterilization. The capital and processing cost are shown. The start of operation is expected in March, 1986. At present, a CASSITRON is being installed in the SPI food processing factory, and starts operation in a few weeks. (Kako, I.)

  5. Digital radiography: Review, status, perspectives

    International Nuclear Information System (INIS)

    Pfeiler, M.; Marhoff, P.

    1989-01-01

    The contribution is intended as a status report, assessing current digital radiography from the angle of view of the year 1983, placing emphasis on digital imaging with the image enhancement and television equipment, discussing the luminescent foil technique in great detail. The article deals with the interpretation of the term resolution, necessary in connection with the digital technique, as well as with the possibility offered by the digital technique, to change standards for pulsed fluoroscopic, or stereo operation. The article explains the advantages of real-time image processing as against fluoroscopic operation. The control methods of digital radiography also are digital, as are the communication systems between the various system components (generators, central unit). The prospects of this imaging method are estimated in an extrpolation of the current status. (orig./MG) [de

  6. Dose optimisation in computed radiography

    International Nuclear Information System (INIS)

    Schreiner-Karoussou, A.

    2005-01-01

    After the installation of computed radiography (CR) systems in three hospitals in Luxembourg a patient dose survey was carried out for three radiographic examinations, thorax, pelvis and lumbar spine. It was found that the patient doses had changed in comparison with the patient doses measured for conventional radiography in the same three hospitals. A close collaboration between the manufacturers of the X-ray installations, the CR imaging systems and the medical physicists led to the discovery that the speed class with which each radiographic examination was to be performed, had been ignored, during installation of the digital imaging systems. A number of procedures were carried out in order to calibrate and program the X-ray installations in conjunction with the CR systems. Following this optimisation procedure, a new patient dose survey was carried out for the three radiographic examinations. It was found that patient doses for the three hospitals were reduced. (authors)

  7. System for uncollimated digital radiography

    Science.gov (United States)

    Wang, Han; Hall, James M.; McCarrick, James F.; Tang, Vincent

    2015-08-11

    The inversion algorithm based on the maximum entropy method (MEM) removes unwanted effects in high energy imaging resulting from an uncollimated source interacting with a finitely thick scintillator. The algorithm takes as input the image from the thick scintillator (TS) and the radiography setup geometry. The algorithm then outputs a restored image which appears as if taken with an infinitesimally thin scintillator (ITS). Inversion is accomplished by numerically generating a probabilistic model relating the ITS image to the TS image and then inverting this model on the TS image through MEM. This reconstruction technique can reduce the exposure time or the required source intensity without undesirable object blurring on the image by allowing the use of both thicker scintillators with higher efficiencies and closer source-to-detector distances to maximize incident radiation flux. The technique is applicable in radiographic applications including fast neutron, high-energy gamma and x-ray radiography using thick scintillators.

  8. Vertebral Fracture Assessment in Supine Position : Comparison by Using Conventional Semiquantitative Radiography and Visual Radiography

    NARCIS (Netherlands)

    Hospers, Ilone C.; van der Laan, Johan G.; Zeebregts, Clark J.; Nieboer, Patrick; Wolffenbuttel, Bruce H. R.; Dierckx, Rudi A.; Kreeftenberg, Herman G.; Jager, Pieter L.; Slart, Riemer H. J. A.

    Purpose: To retrospectively evaluate the accuracy of vertebral fracture assessment (VFA) performed with the patient in the supine position and conventional semiquantitative radiography of the spine by using conventional visual radiography of the spine as the reference standard. Materials and

  9. Neutron radiography application to archaeological and ethnological objects

    International Nuclear Information System (INIS)

    Masuzawa, Fumitake

    1989-01-01

    Neutron radiography testing (NRT) has been applied to several ancient relics using Kyoto University Research Reactor and the cyclotron-based facility of Sumitomo Heavy Industries, Ltd. Some of the results are presented with comments on the usage and applicability of NRT in researches of ancient cultural property. The objects studied are (1) unearthed Buddhist sutras in a bronze case, (2) unearthed glass beads, a silver hollow bead ball and string in a gilt copper alloy case with a lid, (3) a Tibetan Buddhist clay statue cushioned with cloth in a copper box with a glass window and (4) an excavated iron sword conserved and restored using synthetic resins. From comparisons with X-ray radiography testing, NRT is remarkably effective to distinguish organic objects from inorganic materials such as metals and pottery. (author)

  10. Radiological emergencies in industry (causes and consequences). Address at the second national course of Radiation Safety in Industry. Jun 5-7 2000 Guatemala

    International Nuclear Information System (INIS)

    Estrada, Edgar

    2000-06-01

    The address discusses the following issues: review of accidents in industrial radiography, human factors, technical failures, factors that decrease risk, personnel training, design of equipment and recommendations

  11. Optimization of hindfoot alignment radiography.

    Science.gov (United States)

    Yang, Chonglin; Xu, Xiangyang; Hu, Mu; Wang, Bibo; Zhu, Yuan; Liu, Jinhao

    2017-06-01

    Background Cobey and Buck described methods to evaluate hindfoot alignment, but it is still unclear which method is better and easier to perform in clinical practice. Purpose To evaluate the optimal method for radiography of hindfoot alignment. Material and Methods We randomly selected 50 patients visiting the foot and ankle surgery outpatient department who underwent hindfoot alignment radiography between 1 July and 31 August 2015. Radiographs were taken using both Cobey's and Buck's methods. The patients were divided into three groups by calcaneal inclination angle. We assessed the calcaneotibial angle, calcaneovertical angle, and the distance from the bottom of the calcaneus to the mid-tibial axis. A comparative analysis was performed separately using the t-test. Results One hundred pairs of data for Cobey's and Buck's methods were obtained. The angles were analyzed separately in valgus, normal, and varus situations. The results showed no significant difference between Cobey's method and Buck's method regardless of any situation ( P > 0.05). Regarding the distance between the bottom of the calcaneus and the mid-tibial axis, the average result of Buck's method was about 1 mm larger than that of Cobey's method in the valgus and normal cases ( P  0.05). Conclusion Cobey's and Buck's techniques are the classic and popular hindfoot alignment assessment methods. The use of Buck's technique resulted in a better image with a less technical procedure and less time requirement. It is worthy of being popularized and used routinely for hindfoot radiography.

  12. Medical radiography with fast neutrons

    International Nuclear Information System (INIS)

    Duehmke, E.

    1980-01-01

    Neutron radiography is important in medicine for two reasons. On the one hand, macroradiographical findings are different from X-ray findings, i.e. new information may be gained on the morphology of humans and animals. On the other hand, there is a direct practical application in the radiotherapy of malignant tumours if one considers the assessment of the growth of malignant processes. Fast neutrons are required for neutron radiographies of biological objects with a diameter of more than 2 cm. In addition sensitive, two-dimensional detectors must be used which are selective for fast neutrons. The book describes the optimisation and sensitisation of a detector using the example of cellulose nitrate foil for fast reactor neutrons. Images of human spinal chords with tumours proved by pathological and anatomical examinations give a better picture of the dimensions of the tumour than comparative X-ray pictures. For examinations of living patients, neutron radiography should be applied only in those tumour-bearing parts of the bodies in which radiation treatment is required for therapeutical purposes anyway. (orig./MG) [de

  13. Image rejects in general direct digital radiography

    International Nuclear Information System (INIS)

    Hofmann, Bjørn; Rosanowsky, Tine Blomberg; Jensen, Camilla; Wah, Kenneth Hong Ching

    2015-01-01

    The number of rejected images is an indicator of image quality and unnecessary imaging at a radiology department. Image reject analysis was frequent in the film era, but comparably few and small studies have been published after converting to digital radiography. One reason may be a belief that rejects have been eliminated with digitalization. To measure the extension of deleted images in direct digital radiography (DR), in order to assess the rates of rejects and unnecessary imaging and to analyze reasons for deletions, in order to improve the radiological services. All exposed images at two direct digital laboratories at a hospital in Norway were reviewed in January 2014. Type of examination, number of exposed images, and number of deleted images were registered. Each deleted image was analyzed separately and the reason for deleting the image was recorded. Out of 5417 exposed images, 596 were deleted, giving a deletion rate of 11%. A total of 51.3% were deleted due to positioning errors and 31.0% due to error in centering. The examinations with the highest percentage of deleted images were the knee, hip, and ankle, 20.6%, 18.5%, and 13.8% respectively. The reject rate is at least as high as the deletion rate and is comparable with previous film-based imaging systems. The reasons for rejection are quite different in digital systems. This falsifies the hypothesis that digitalization would eliminates rejects. A deleted image does not contribute to diagnostics, and therefore is an unnecessary image. Hence, the high rates of deleted images have implications for management, training, education, as well as for quality

  14. Neutron radiography at the Risoe National Laboratory

    International Nuclear Information System (INIS)

    Domanus, J.C.; Gade-Nielsen, P.; Knudsen, P.; Olsen, J.

    1981-11-01

    In this report six papers are collected which will be presented at the First World Conference on Neutron Radiography in San Diego, U.S.A., 7 - 10 December 1981. They are preceded by a short description of the activities of Risoe National Laboratory in the field of post-irradiation examination of nuclear fuel. One of the nondestructive methods used for this examination is neutron radiography. In the six conference papers different aspects of neutron radiography performed at Risoe are presented. (author)

  15. Assessment of risk of potential exposures on facilities industries

    International Nuclear Information System (INIS)

    Leocadio, Joao Carlos

    2007-03-01

    This work develops a model to evaluate potential exposures on open facilities of industrial radiography in Brazil. This model will decisively contribute to optimize operational, radiological protection and safety procedures, to prevent radiation accidents and to reduce human errors in industrial radiography. The probabilistic safety assessment (PSA) methodology was very useful to assess potential exposures. The open facilities of industrial radiography were identified as the scenario to be analyzed in what concerns the evaluation of potential exposures, due to their high accidents indices. The results of the assessment of potential exposures confirm that the industrial radiography in Brazil is a high-risk practice as classified by the IAEA. The risk of potential exposure was estimated to be 40,5 x 10 -2 per year in Brazil, having as main consequences injuries to the workers' hands and arms. In the world scene, the consequences are worst, leading to fatalities of people, thus emphasizing the high risk of industrial radiography. (author)

  16. Fast neutron radiography in biology and medicine

    International Nuclear Information System (INIS)

    Duehmke, E.; Greim, L.

    1983-01-01

    Fast neutrons are necessary for neutron radiography of extended biological objects. Applying cellulose nitrate foils to assure specific neutrograms undisturbed by X- and γ-ray effects, a multifoil stack can be used as detector in order to improve image quality and to reduce neutron dose down to less than 10 rem. Neutron radiography enables to observe the exsiccation process in biological materials, e.g. wood, which could not be achieved by X-ray radiography. In medicine neutron radiography could be of value for detecting pathological changes within bone such as replacement of bone marrow by fat or tumor, as shown in human vertebral columns. (Auth.)

  17. Absorbed and effective dose in direct and indirect digital panoramic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gun Sun; Kim, Jin Soo; Kim, Jae Duk [Department of Oral and Maxilloficial Radiology School of Dentistry, Oral Biology Research Institute, Chosun University, Gwangju (Korea, Republic of)

    2010-03-15

    We evaluated the absorbed doses to the organs and calculated the effective doses when using the digital panoramic radiography. The absorbed dose averages in major organs of oral and maxillofacial region were measured using the Dental head phantom (CIRS Co., USA), nLi2B4O7 TLD chip and UD-716AGL dosimeter (Matsushita Electric Industrial Co., JPN) when performing indirect and direct digital panoramic radiography. Effective doses were calculated from correspond to ICRP 2007 recommendations for two panoramic radiography. The absorbed dose average on indirect and direct digital panoramic radiography was highest in parotid glands as measured 1259.6 mGy and 680.7 mGy respectively. Absorbed dose average in another organs were high in order of esophagus, submandibular gland, tongue and thyroid gland on both types of digital panoramic radiography. The absorbed dose average was higher on indirect type than direct one (p?0.05). The effective dose was higher on indirect type than direct one as measured 13.28 mSv and 8.70 mSv respectively. The absorbed doses in salivary gland and oral mucosa were high. However, thyroid gland also demands the attention on radiography due to high tissue weighting factor in spite of the low absorbed dose.

  18. Absorbed and effective dose in direct and indirect digital panoramic radiography

    International Nuclear Information System (INIS)

    Lee, Gun Sun; Kim, Jin Soo; Kim, Jae Duk

    2010-01-01

    We evaluated the absorbed doses to the organs and calculated the effective doses when using the digital panoramic radiography. The absorbed dose averages in major organs of oral and maxillofacial region were measured using the Dental head phantom (CIRS Co., USA), nLi2B4O7 TLD chip and UD-716AGL dosimeter (Matsushita Electric Industrial Co., JPN) when performing indirect and direct digital panoramic radiography. Effective doses were calculated from correspond to ICRP 2007 recommendations for two panoramic radiography. The absorbed dose average on indirect and direct digital panoramic radiography was highest in parotid glands as measured 1259.6 mGy and 680.7 mGy respectively. Absorbed dose average in another organs were high in order of esophagus, submandibular gland, tongue and thyroid gland on both types of digital panoramic radiography. The absorbed dose average was higher on indirect type than direct one (p?0.05). The effective dose was higher on indirect type than direct one as measured 13.28 mSv and 8.70 mSv respectively. The absorbed doses in salivary gland and oral mucosa were high. However, thyroid gland also demands the attention on radiography due to high tissue weighting factor in spite of the low absorbed dose.

  19. Isotopes and radiation for modern industry

    International Nuclear Information System (INIS)

    Machi, S.; Yuan, H.C.; Sevastyanov, Y.G.

    1983-01-01

    Brief information is given on the industrial use of isotope and radiation technology in the following fields: radiosterilization of medical supplies, non-destructive testing by radiography, wear and corrosion studies, on-line controls, exploration and recovery of minerals

  20. The industrial uses of neutrons

    International Nuclear Information System (INIS)

    Johnson, M.W.

    1994-01-01

    This paper deals with the neutron scattering and radiography techniques that have been used to solve industrial problems. Over the last ten years the application of neutron techniques to industrial problems has grown as neutron techniques have evolved to study ever more complex systems. The problems raised by industry use a wide spectrum of the neutron scattering techniques available, although some techniques are used frequently - especially for studying residual stress, Small Angle Neutron Scattering (SANS) for studying large scale structures, reflectometry and radiography. This paper reviews the techniques involved and illustrates the new problems that are now being solved using accelerator-based pulsed neutron scattering techniques.(author), 26 refs., 8 figs

  1. Computer processing techniques in digital radiography research

    International Nuclear Information System (INIS)

    Pickens, D.R.; Kugel, J.A.; Waddill, W.B.; Smith, G.D.; Martin, V.N.; Price, R.R.; James, A.E. Jr.

    1985-01-01

    In the Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, and the Center for Medical Imaging Research, Nashville, TN, there are several activities which are designed to increase the information available from film-screen acquisition as well as from direct digital acquisition of radiographic information. Two of the projects involve altering the display of images after acquisition, either to remove artifacts present as a result of the acquisition process or to change the manner in which the image is displayed to improve the perception of details in the image. These two projects use methods which can be applied to any type of digital image, but are being implemented with images digitized from conventional x-ray film. One of these research endeavors involves mathematical alteration of the image to correct for motion artifacts or registration errors between images that will be subtracted. Another applies well-known image processing methods to digital radiographic images to improve the image contrast and enhance subtle details in the image. A third project involves the use of dual energy imaging with a digital radiography system to reconstruct images which demonstrate either soft tissue details or the osseous structures. These projects are discussed in greater detail in the following sections of this communication

  2. EFFECTS OF TERRORISM IN TOURISM INDUSTRY : A Case Study of 9/11 Terrorist Attacks in World Trade Center

    OpenAIRE

    Ranabhat , Krishna

    2015-01-01

    Rapid growth of tourism industry has been a good sign of business. International tourism is co-operation between countries. The development of global economy is depending upon the global tourism industry. Social network is directly and indirectly affected by terrorism activities. There are push and pull factor in tourism. Terrorism is a pull factor that is considered a negative factor. Terrorism is the biggest factor, which pushes tourism industry down. Terrorism brings fear to tourists, whic...

  3. Simple radiography by Imaging Plate

    Energy Technology Data Exchange (ETDEWEB)

    Takata, Shigeru; Koyama, Motoko; Tanizaki, Yoshiyuki [Tokyo Metropolitan Industrial Technology Research Insitute, Tokyo (Japan)

    1998-12-31

    Photo-stimulable phosphor is a material which emits luminescence by incitement of light. As useful photo-stimulable phosphor, alkali halide, like BaFBr: Eu, II - VI compound, like SrS: Eu and oxide, such as Al{sub 2}O{sub 3}: Care reported at present. Imaging Plate is a popular name of products, which is composed of thin layer of the phosphor fixed plastic plate. Photo-stimulable luminescence of Imaging Plate is emitted by scanning with narrow beam of incitement light. The light of luminescence is separated from incitement light by filter and it`s intensity is measured. The intensity of luminescence is proportional to absorbed dose of Imaging Plate from incident radiation. The map of luminescence intensity makes radiation image like radiograph taken by X-ray film. Reusability and usability of digital image are another advantage. The problem to solve of Imaging Plate are less resolution than X-ray film, expensive reading instrument and fading, which means decrease of luminescence intensity depend on elapse time after irradiation. High sensitivity of Imaging Plate makes possible of simple radiography by small radiation source. In Japanese law, sealed radioisotopes source less than 3.7 MBq can use without permission and register. If radiograph can be taken by sealed source less than 3.7 MBq, application of radiography is widely developed. So we try to take radiographs of some objects using Imaging Plate and sealed radioisotope sources under 3.7 MBq. As the result, useful radiographs are taken under conditions that exposure time is more than a few hours and distance between the source and the Plate is less than 30 cm. Quality of the image is poor than general radiograph by large radiation source. But the simple radiography taken by small source is of great value. (J.P.N.)

  4. Neutron radiography imaging of hydrogen containing materials

    International Nuclear Information System (INIS)

    Balasko, M.; Svab, E.; Koeroesi, F.

    1998-01-01

    This work was performed at the dynamic neutron radiography station at the 10MW Budapest research reactor within the framework of the IAEA Co-ordinated Research Programme on ''Bulk Hydrogen Analysis, using Neutrons''. Neutron radiography has been successfully applied in various fields of hydrogen containing materials

  5. Better imaging: the advantages of digital radiography

    NARCIS (Netherlands)

    van der Stelt, P.F.

    2008-01-01

    Background. Digital radiography has been available in dentistry for more than 25 years, but it has not replaced conventional film-based radiography completely. This could be because of the costs involved in replacing conventional radiographic equipment with a digital imaging system, or because

  6. Application of computed radiography to ERCP

    International Nuclear Information System (INIS)

    Lee, Shigeki; Mochizuki, Fukuji; Fujita, Naotaka; Itoh, Shoichiro; Ikeda, Takashi; Toyohara, Tokiaki; Matsumoto, Kyoichi

    1984-01-01

    Computed radiography technic was applied to ERCP. Fuji Computed Radiography System was used. The pancreatogram obtained by this method was compared with that of conventional screen-film radiograph. The much finer changes of the pancreatogram can be delineated by the new method. The diagnostic ability of ERCP is thus enhanced by the introduction of FCR. (author)

  7. Multiple imaging radiography at LNLS

    Energy Technology Data Exchange (ETDEWEB)

    Hoennicke, M.G. [LORXI, Departamento de Fisica, Universidade Federal do Parana, Caixa Postal 19091, 81531-990 Curitiba (Brazil)], E-mail: marcelohonnicke@yahoo.com.br; Cusatis, C. [LORXI, Departamento de Fisica, Universidade Federal do Parana, Caixa Postal 19091, 81531-990 Curitiba(Brazil); Antunes, A. [Departamento de Fisica Aplicada, Instituto de Fisica, Universidade de Sao Paulo, Caixa Postal 66318, 05315-970 Sao Paulo (Brazil); Safatle, A.M.V.; Barros, P.S.M. [Laboratorio de Oftalmologia Experimental e Comparativa, Departamento de Cirurgia, Faculdade de Medicina Veterinaria, Universidade de Sao Paulo, 05508-900 Sao Paulo (Brazil); Morelhao, S.L. [Departamento de Fisica Aplicada, Instituto de Fisica, Universidade de Sao Paulo, Caixa Postal 66318, 05315-970 Sao Paulo (Brazil)

    2008-01-11

    An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.

  8. Patient risk from interproximal radiography

    International Nuclear Information System (INIS)

    Gibbs, S.J.; Pujol, A. Jr.; Chen, T.S.; Malcolm, A.W.; James, A.E. Jr.

    1984-01-01

    Computer simulation methods for determining patient dose from dental radiography have demonstrated that patient risk from a two-film interproximal examination ranges from 1.1 X 10(-8) to 3.4 X 10(-7) using 90-kVp beams, depending on film speed, projection technique, and age and sex of the patient. Further, changing from a short-cone round-beam to a long-cone technique with rectangular collimation reduces risk by a factor of 2.9, independent of other factors

  9. Patient dosimetry during chest radiography

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, O.; Kosutic, D.; Markovic, S.

    2004-01-01

    Reasons for the variation in patient doses from chest radiography procedure were investigated by assessing entrance skin doses from kerma-area product measurements. Data were collected from seven x-ray tubes in five hospitals involving 259 adult patients. The third quartile value was 0.81 mGy compared to general reference level of 0.30 mGy. The applied tube potential was main contributor to patient dose variation. If department use at least 90 k Vp, the mean entrance surface dose would be reduced ut to factor six. Modification of departmental procedure is correct approach for dose reduction in diagnostic radiology. (author) [sr

  10. Time-gated energy-selected cold neutron radiography

    CERN Document Server

    McDonald, T E; Claytor, T N; Farnum, E H; Greene, G L; Morris, C

    1999-01-01

    A technique is under development at the Los Alamos Neutron Science Center (LANSCE), Manuel Lujan Jr. Neutron Scattering Center (Lujan Center) for producing neutron radiography using only a narrow energy range of cold neutrons. The technique, referred to as time-gated energy-selected (TGES) neutron radiography, employs the pulsed neutron source at the Lujan Center with time of flight to obtain a neutron pulse having an energy distribution that is a function of the arrival time at the imager. The radiograph is formed on a short persistence scintillator and a gated, intensified, cooled CCD camera is employed to record the images, which are produced at the specific neutron energy range determined by the camera gate. The technique has been used to achieve a degree of material discrimination in radiographic images. For some materials, such as beryllium and carbon, at energies above the Bragg cutoff the neutron scattering cross section is relatively high while at energies below the Bragg cutoff the scattering cross ...

  11. Digital chest radiography: collimation and dose reduction

    DEFF Research Database (Denmark)

    Debess, Jeanne; Johnsen, Karen Kirstine; Vejle-Sørensen, Jens Kristian

    Purpose: Quality improvement of basic radiography focusing on collimation and dose reduction in digital chest radiography Methods and Materials:A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from...... one hundred fifty self-reliant female patients between 15 and 55 years of age are included in the study. The clinical research is performed between September and November 2014 where 3rd year Radiography students collect data on four Danish x-ray departments using identical procedures under guidance...... at the conference. Conclusion: Collimation improvement in basic chest radiography can reduce the radiation to female patients at chest x-ray examinations....

  12. Better imaging: the advantages of digital radiography.

    Science.gov (United States)

    van der Stelt, Paul F

    2008-06-01

    Digital radiography has been available in dentistry for more than 25 years, but it has not replaced conventional film-based radiography completely. This could be because of the costs involved in replacing conventional radiographic equipment with a digital imaging system, or because implementing new technology in the dental practice requires a bit of courage. When the practitioner is fully aware of the new possibilities offered by digital radiography, he or she can make a more informed decision about adopting it. This article offers information about digital radiography, not just as a replacement of conventional radiography, but also as a concept offering benefits beyond those of conventional radiography. Digital radiographs are composed of a set of numbers arranged as a grid of rows and columns. The dentist can perform mathematical operations on these numbers to create a new image in which certain characteristics are enhanced, thus making interpretation of the image easier. The dentist also can correct, to some extent, overexposed or underexposed images and can optimize contrast and brightness for specific diagnostic procedures, such as caries detection and bone level assessment. More advanced procedures are available as well, such as digital subtraction radiography and computer-aided recognition of image features. The author presents a selection of the advantages of digital radiography that are not achievable with conventional film-based radiography. Implementing digital radiography in the dental office requires additional training. However, once members of the dental team have gone through this initial phase, they have the benefits of several new diagnostic possibilities. With a digital system, information from radiographic images is collected more easily and in a more objective way, which will improve the performance of the diagnostic process.

  13. Radiation protection in equine radiography

    International Nuclear Information System (INIS)

    Wood, A.K.W.; Reynolds, K.M.; Leith, I.S.; Burns, P.A.

    1974-01-01

    During radiography of the carpus of horses calcium fluoride thermoluminescent dosemeters were used to measure the radiation exposure to the hand of an assistant positioning the x-ray film. Three portable x-ray machines and a mobile machine were used during the recordings. The effects of x-ray machine, radiographic technique, and lead rubber gloves upon radiation exposure to the hand were investigated. The size of the primary beam of the x-ray machine was found to be the major factor in determining the dose of radiation received by the hand. The highest radiation exposures were recorded when using two portable machines which were fitted with beam limiting devices that permitted only one primary beam size. The lowest exposures were measured when radiographs were taken with the mobile machine that was fitted with a light beam diaphragm. The control of primary beam size with a light beam diaphragm was found to be the most effective method of reducing radiation dosage to the hand. It is strongly recommended that for equine radiography a light beam diaphragm be fitted to and used on all x-ray machines, and a cassette holder be used to keep the hands out of the primary beam. (author)

  14. Optimizing digital radiography of children

    International Nuclear Information System (INIS)

    Willis, Charles E.

    2009-01-01

    Pediatric projection imaging differs from imaging of the adult patient. Children are smaller, more radiosensitive, and less compliant than their adult counterparts. Their characteristics affect the way projection imaging is practiced and how dose is optimized. Computed radiography (CR) and digital radiography (DR) have been embraced by pediatric practitioners in order to reduce dose and improve image quality. Unfortunately, dose optimization with CR and DR has been hampered by a lack of definition of appropriate exposure levels, a lack of standardization in exposure factor feedback, and a lack of understanding of the fundamentals of CR and DR technology. The potential for over-exposure exists with both CR and DR. Both the Society for Pediatric Radiology and the American Association of Physicists in Medicine recognize the promise and shortcomings of CR and DR technology and have taken steps to join with manufacturers in improving the practice of CR and DR imaging. Although the risks inherent in pediatric projection imaging with CR and DR are low, efforts to reduce dose are worthwhile, so long as diagnostic quality is maintained. Long-standing recommendations for limiting radiation dose in pediatric projection imaging are still applicable to CR and DR.

  15. A User-Centered Mobile Cloud Computing Platform for Improving Knowledge Management in Small-to-Medium Enterprises in the Chilean Construction Industry

    Directory of Open Access Journals (Sweden)

    Daniela Núñez

    2018-03-01

    Full Text Available Knowledge management (KM is a key element for the development of small-to-medium enterprises (SMEs in the construction industry. This is particularly relevant in Chile, where this industry is composed almost entirely of SMEs. Although various KM system proposals can be found in the literature, they are not suitable for SMEs, due to usability problems, budget constraints, and time and connectivity issues. Mobile Cloud Computing (MCC systems offer several advantages to construction SMEs, but they have not yet been exploited to address KM needs. Therefore, this research is aimed at the development of a MCC-based KM platform to manage lessons learned in different construction projects of SMEs, through an iterative and user-centered methodology. Usability and quality evaluations of the proposed platform show that MCC is a feasible and attractive option to address the KM issues in SMEs of the Chilean construction industry, since it is possible to consider both technical and usability requirements.

  16. Application of neutron radiography to visualization of multiphase flows

    International Nuclear Information System (INIS)

    Takenaka, N.; Fujii, T.; Nishizaki, K.; Asano, H.; Ono, A.; Sonoda, K.; Akagawa, K.

    1990-01-01

    Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author)

  17. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  18. Filmless radiography - present possibilities and direction of future developing

    International Nuclear Information System (INIS)

    Wocial, A.; Wojciechowski, Z.A.; Rozenblicki, Z.

    2008-01-01

    The paper presents introduction for new filmless radiography like CR Computed Radiography and DR Digital Radiography direct and non direct. The main factors are considered, which determine classification to different type of radiography. For each technique authors describe advantages and disadvantages supporting by practice examples. Paper contains a lot of practical information about a most of existing radiographic equipment at the NDT market. (author)

  19. Center for Corporate Climate Leadership: Direct Fugitive Emissions from Refrigeration, Air Conditioning, Fire Suppression, and Industrial Gases

    Science.gov (United States)

    This guidance document focuses on several fugitive emissions sources that are common for organizations in many sectors: refrigeration and air conditioningsystems, fire suppression systems, and the purchase and release of industrial gases.

  20. Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)

    International Nuclear Information System (INIS)

    Akimoto, Kazumi

    1991-01-01

    Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author)

  1. Quasi-monochromatic parallel radiography utilizing a computed radiography system

    International Nuclear Information System (INIS)

    Sato, E.; Hayasi, Y.; Germer, R.; Tanaka, E.; Mori, H.; Kawai, T.; Ichimaru, T.; Sato, S.; Takayama, K.; Ido, H.

    2004-01-01

    A fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a copper-target X-ray tube is described. The X-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an X-ray tube. The negative high-voltage is applied to the cathode electrode, and the anode electrode is connected to the ground. In this experiment, the tube voltage was regulated from12-25 kV, and the tube current was regulated within 3.0 mA by the filament temperature. The exposure time was controlled in order to obtain optimum X-ray intensity, and the maximum focal spot dimensions were approximately 2 mmx1.5 mm. The polycapillary plate was J5022-21 (Hamamatsu Photonics Inc.), and the plate thickness was 1.0 mm. The outer, effective, and hole diameters were 87 mm, 77 mm, and 25 μm, respectively. Quasi-monochromatic X-rays were produced using a 10 μm-thick copper filter, and these rays were formed into parallel beams by the polycapillary, and the radiogram was taken using a computed radiography system utilizing imaging plates. In the measurement of image resolution, the resolution fell according to increases in the distance between the chart and imaging plate using a polycapillary. We could observe a 50 μm tungsten wire clearly, and fine blood vessels of approximately 100 μm were visible in angiography

  2. New electronic imaging system for Cf-252 based neutron radiography

    International Nuclear Information System (INIS)

    Ito, S.; Mochiki, K.; Matsumoto, T.

    2004-01-01

    We have developed a new imaging camera and a signal processing system for Cf-252 based neutron radiography. The imaging part consists of cascaded image intensifiers and a progressive-scan monochromatic CCD camera (SONY XC-55) with standard frame rate. The video signal is converted to 12 bits and processed by large-scale field programmable arrays (FPGAs). The signal processing system has three frame accumulation memories for normal frame images, binary-converted frame images and center-of-gravity frame images. A preliminary experiment was made using a Cf-252 neutron source at Atomic Energy Research Laboratory of Musashi Institute of Technology. (author)

  3. Radiography

    International Nuclear Information System (INIS)

    Williams, A.M.

    1979-01-01

    A mechanical arrangement for use in computerized tomographic apparatus so as to permit the examination of volumetric body slices and body slices tilted with respect to the examination axis is described. The radiation source is mounted on an inner tilt frame which can rotate, by way of a lockable bearing, in an outer tilt frame which can be tilted relative to a sub frame which can be locked or free relative to the main frame of the apparatus. The outer tilt frame can also rotate, relative to the main frame, in a lockable bearing

  4. Advantages obtained in radiation protection when using computerized radiography tests - CR (digital) in processing plants

    International Nuclear Information System (INIS)

    Jose, Joao Carlos Videira; Milani, Hilton Sergio B.; Paes, Eliseu Almir de Oliveira; Boita, Mario de; Souza, Laercio de; Serra, Flavio Augusto dos Santos

    2002-01-01

    During the year 2000, the ARCtest initiated the development of the research for adapting the Computerized Radiography - CR, originally conceived for medical applications, for the Industry, trying initially to attend the requirements of the processing plants, concerning to the detection of deterioration mechanisms (evaluation of the piping integrity). Due to the obtained excellent results, the possibility of utilization the Computerized Radiography - CR in the radiographic inspection were studied during the shutdown of the Catalytic Cracking Unit of the PETROBRAS-REPLAN, specifically in the replacement of the CO boiler superheater, where a large number of the small diameter welded joints have been predicted

  5. A light, superconducting H- cyclotron for medical diagnostics and neutron radiography

    International Nuclear Information System (INIS)

    Finlan, M.F.; Kruip, M.; Wilson, M.N.

    1987-01-01

    Oxford Instruments, working in close collaboration with Amersham International are developing a compact, lightweight, low radiation field superconducting cyclotron. The combination of superconductivity, H - acceleration and no internal yoke as such makes this possible. It is intended for use as a generator of short half lived isotopes for use in hospitals for PET and other imaging procedures, for use in industrial PET imaging, and as a neutron generator for neutron radiography. With a weight of 2000 kg, it is transportable and comparitively easy to handle and is capable in the 17 MeV version of generating 1.8 10 13 neutrons/second for neutron radiography. (author)

  6. Environmental Analysis of The Impacts of Batik Waste Water Polution on The Quality of Dug Well Water in The Batik Industrial Center of Jenggot Pekalongan City

    Science.gov (United States)

    Budiyanto, Slamet; Anies; Purnaweni, Hartuti; Sunoko, Henna Rya

    2018-02-01

    The city of Pekalongan known as "Kota Batik" is one of Batik Industrial Centers in Indonesia with 917 batik industry. There are 203 batik industries located in Jenggot Village, which is the biggest batik industrial center in Pekalongan City. The process of making batik requires a dye derived from synthetic dyes containing heavy metals. Most of the waste is directly discharged into the environment without going through the processing first. This is due to the lack of optimal management of existing WWTP as well as lack of public awareness of environmental conservation. This condition has a negative impact on the surrounding community, especially in terms of environmental health. The result of measurement of 5 (five) batik industrial waste outlets and 5 point of batik waste water in residential sewer shows almost equal number for 3 (three) parameters of heavy metals Cd, Cr and Pb with average number: Cd 0.07 Mg / L, Cr 0.76 mg / L and Pb 0.78 mg / L. These three parameters exceed the maximum level of quality standard established by Government Regulation No.82 of 2001 on Water Quality Management and Water Pollution Control. The average result of the water quality measurement of the well digging population to the heavy metal content are: Cd 0,001 mg / L, Cr 0,002 mg / L and Pb 0.04 mg / L. Of the three parameters of heavy metals, heavy metals of Pb are on average higher than the maximum level of quality standards established by Decree of the Minister of Health Number. 492 / Menkes / Per / IV / 2010 regarding Water Quality Requirements. Potential occurrence of dug well water contamination due to infiltration of batik waste water is big enough. Survey results of 15 dug wells show that the construction of dug wells is not sufficient. There is a dug well with a damaged outer wall of 16.1%, damaged inner wall of 17.9% and a damaged well floor of 19.7%. Improper well construction impacts on the infiltration of batik waste water into the well. Survey results of physical well

  7. Neutron radiography inspection of investment castings

    International Nuclear Information System (INIS)

    Richards, W.J.; Barrett, J.R.; Springgate, M.E.; Shields, K.C.

    2004-01-01

    Investment casting, also known as the lost wax process, is a manufacturing method employed to produce near net shape metal articles. Traditionally, investment casting has been used to produce structural titanium castings for aero-engine applications with wall thickness less than 1 in (2.54 cm). Recently, airframe manufacturers have been exploring the use of titanium investment casting to replace components traditionally produced from forgings. Use of titanium investment castings for these applications reduces weight, cost, lead time, and part count. Recently, the investment casting process has been selected to produce fracture critical structural titanium airframe components. These airframe components have pushed the traditional inspection techniques to their physical limits due to cross sections on the order of 3 in (7.6 cm). To overcome these inspection limitations, a process incorporating neutron radiography (n-ray) has been developed. In this process, the facecoat of the investment casting mold material contains a cocalcined mixture of yttrium oxide and gadolinium oxide. The presence of the gadolinium oxide, allows for neutron radiographic imaging (and eventual removal and repair) of mold facecoat inclusions that remain within these thick cross sectional castings. Probability of detection (POD) studies have shown a 3x improvement of detecting a 0.050x0.007 in 2 (1.270x0.178 mm 2 ) inclusion of this cocalcined material using n-ray techniques when compared to the POD using traditional X-ray techniques. Further, it has been shown that this n-ray compatible mold facecoat material produces titanium castings of equal metallurgical quality when compared to the traditional materials. Since investment castings can be very large and heavy, the neutron radiography facilities at the University of California, Davis McClellan Nuclear Radiation Center (UCD/MNRC) were used to develop the inspection techniques. The UCD/MNRC has very unique facilities that can handle large parts

  8. Direct magnification radiography of the hand

    International Nuclear Information System (INIS)

    Presacco, D.; Pellegrini, A.; Di Maggio, C.

    1987-01-01

    The value of direct magnification radiography of the hand and the wrist has been studied in 128 patients affected by rheumatic diseases. Only in a small group (3.17%) magnification determined a higher percentage of correct diagnosis; in the 17.06% of cases direct magnification radiography provided useful increase in information but did not change the diagnisis correctly reached by conventional techniques. In most cases (79.76%) magnification provided only a better image quality but no more information helpful for the diagnosis, because of the high level achieved by convetional techniques. Therefore direct magnification radiography must be used only in selected cases and not as routine radiographyc technique

  9. Application of proton radiography to medical imaging

    International Nuclear Information System (INIS)

    Kramer, S.L.; Martin, R.L.; Moffett, D.R.; Colton, E.

    1977-12-01

    The use of charged particles for radiographic applications has been considered for some time, but progress has been impeded by the cost and availability of suitable accelerators. However, recent developments in technology could overcome these problems. A review is presented of the physical principles leading to an improvement in mass resolution per unit of absorbed dose for charged particle radiography relative to x-ray radiography. The quantitative comparisons between x-ray and proton radiographs presented here confirm this advantage. The implications of proton radiography on cancer detection, as well as future plans for developing a proton tomographic system, are discussed

  10. BASIC PRINCIPLES OF THE PYRAMIDS TEMPORAL BONE RADIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Mirko Krstić

    2007-10-01

    Full Text Available This paper shows the possibilities and advantages of certain methods of temporal bone radiography in diagnosing pathological conditions and diseases of temporal bones, with description of basic techniques of radiological examinations: Mayer’s axial view of the pyramids, the Stenvers view of the pyramids, the Arcelini view of the pyramids, comparative pyramid radiography by Hass, comparative pyramid radiography by Gras-hey, comparative pyramid radiography in submentovertical projection and comparative pyramid radiography in verticosubmental projection.

  11. High resolution digital radiography system

    International Nuclear Information System (INIS)

    Stein, J.

    1983-01-01

    A digital radiography system includes an x-ray source for projecting a beam of x-rays toward and through an object to be examined onto the input face of an image intensifier tube. A multi-hole collimator is disposed between the object and the image intensifier tube for producing a two-dimensional array of spaced pencil beams, and these pencil beams are raster scanned relative to the object being examined and across the input face of the image intensifier tube through small distances corresponding generally to the distance between the holes in the collimator. The succession of images which are produced on the output face of the image intensifier tube during the scanning of the pencil beams are scanned by a video camera whose output signals are digitized and stored as partial images, and the partial images are thereafter interleaved with one another to provide a composite comparatively high resolution image of the object being examined

  12. Proton Radiography at Los Alamos

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, Alexander [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-28

    The proton radiography (pRad) facility at Los Alamos National Lab uses high energy protons to acquire multiple frame flash radiographic sequences at megahertz speeds: that is, it can make movies of the inside of explosions as they happen. The facility is primarily used to study the damage to and failure of metals subjected to the shock forces of high explosives as well as to study the detonation of the explosives themselves. Applications include improving our understanding of the underlying physical processes that drive the performance of the nuclear weapons in the United States stockpile and developing novel armor technologies in collaboration with the Army Research Lab. The principle and techniques of pRad will be described, and examples of some recent results will be shown.

  13. Computed radiography systems performance evaluation

    International Nuclear Information System (INIS)

    Xavier, Clarice C.; Nersissian, Denise Y.; Furquim, Tania A.C.

    2009-01-01

    The performance of a computed radiography system was evaluated, according to the AAPM Report No. 93. Evaluation tests proposed by the publication were performed, and the following nonconformities were found: imaging p/ate (lP) dark noise, which compromises the clinical image acquired using the IP; exposure indicator uncalibrated, which can cause underexposure to the IP; nonlinearity of the system response, which causes overexposure; resolution limit under the declared by the manufacturer and erasure thoroughness uncalibrated, impairing structures visualization; Moire pattern visualized at the grid response, and IP Throughput over the specified by the manufacturer. These non-conformities indicate that digital imaging systems' lack of calibration can cause an increase in dose in order that image prob/ems can be so/ved. (author)

  14. Standard guide for computed radiography

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide provides general tutorial information regarding the fundamental and physical principles of computed radiography (CR), definitions and terminology required to understand the basic CR process. An introduction to some of the limitations that are typically encountered during the establishment of techniques and basic image processing methods are also provided. This guide does not provide specific techniques or acceptance criteria for specific end-user inspection applications. Information presented within this guide may be useful in conjunction with those standards of 1.2. 1.2 CR techniques for general inspection applications may be found in Practice E2033. Technical qualification attributes for CR systems may be found in Practice E2445. Criteria for classification of CR system technical performance levels may be found in Practice E2446. Reference Images Standards E2422, E2660, and E2669 contain digital reference acceptance illustrations. 1.3 The values stated in SI units are to be regarded as the st...

  15. The new cold neutron radiography and tomography instrument CONRAD at HMI Berlin

    Science.gov (United States)

    Hilger, A.; Kardjilov, N.; Strobl, M.; Treimer, W.; Banhart, J.

    2006-11-01

    The new cold neutron radiography instrument CONRAD is a multifunctional facility for radiography and tomography with cold neutrons at Hahn-Meitner Institut, Berlin. It is located at the end of a curved neutron guide, which faces the cold-neutron source of the BER-II research reactor. The geometry provides a cold-neutron beam with wavelengths between 2 and 12 Å. Two measuring positions are available for radiography and tomography investigations. The first one is placed at the end of the guide and it is optimized for in situ experiments in which a high neutron flux is required. The available flux at this position is approximately 10 8 cm -2 s -1. The second measuring position uses a pin-hole geometry which allows better beam collimation ( L/ D up to 1000) and higher image resolution in the range of 200 μm in the CCD based detector system (10×10 cm 2). The use of cold neutrons for radiography purposes increases the image contrast and improves the sensibility e.g., the detection of small amounts of water and hydrogen-containing materials in metal matrixes. On the other hand the cold-neutron beam can be modified easily by using diffraction and neutron optical techniques. This enables to perform radiography and tomography experiments with more sophisticated measuring techniques. Recent examples of research and industrial applications will be presented.

  16. Applications of image plates in neutron radiography and neutron diffraction at BARC, Trombay

    International Nuclear Information System (INIS)

    Shaikh, A.M.

    2013-01-01

    Neutron radiography techniques based on Gd, Dy and In metallic foils and X-ray film have been used at this centre since early seventies for various NDT and R and D work in nuclear, defence and aerospace industries. In recent years use of photostimulated luminescence based phosphor imaging plate has been introduced in our work. This has enabled to achieve higher sensitivities and dynamic ranges of recording radiographs with acceptable spatial resolution. It also provides digital image information which is more convenient for quantitative evaluations. Neutron image plates have been used in variety of radiography techniques such as conventional neutron radiography (NR), neutron induced beta radiography (NIBR), hydrogen sensitive epithermal neutron radiography (HYSEN) and for neutron powder diffractometry using Apsara, CIRUS and Dhruva reactors as neutron sources. Recently the image plates have also been used for characterization of thermalized neutron beam from a plasma focus neutron source and recording neutron radiographs. Prior to the utilization image plates have been characterised for their performance. Details of the measurements and applications will be presented. (author)

  17. Electronic imaging applied to neutron radiography

    International Nuclear Information System (INIS)

    Garrett, D.A.; Bracher, D.A.

    1976-01-01

    A commercially - available image intensifier was used with a scan conversion memory and a mobile 252 Cf based neutron radiography system to obtain neutron radiographs on a television monitor in 0.5 minutes to 10.0 minutes

  18. Plain abdominal radiography in acute abdominal pain; past, present, and future

    Directory of Open Access Journals (Sweden)

    Gans SL

    2012-06-01

    Full Text Available Sarah L Gans,1 Jaap Stoker,2 Marja A Boermeester11Department of Surgery, 2Department of Radiology, Academic Medical Center, University of Amsterdam, Amsterdam, The NetherlandsAbstract: Several studies have demonstrated that a diagnosis based solely on a patient’s medical history, physical examination, and laboratory tests is not reliable enough, despite the fact that these aspects are essential parts of the workup of a patient presenting with acute abdominal pain. Traditionally, imaging workup starts with abdominal radiography. However, numerous studies have demonstrated low sensitivity and accuracy for plain abdominal radiography in the evaluation of acute abdominal pain as well as various specific diseases such as perforated viscus, bowel obstruction, ingested foreign body, and ureteral stones. Computed tomography, and in particular computed tomography after negative ultrasonography, provides a better workup than plain abdominal radiography alone. The benefits of computed tomography lie in decision-making for management, planning of a surgical strategy, and possibly even avoidance of negative laparotomies. Based on abundant available evidence, major advances in diagnostic imaging, and changes in the management of certain diseases, we can conclude that there is no place for plain abdominal radiography in the workup of adult patients with acute abdominal pain presenting in the emergency department in current practice.Keywords: abdominal x-ray, acute abdomen, acute abdominal pain, emergency department, diagnostic imaging, abdominal radiography

  19. The relationship between contrast, resolution and detectability in accelerator-based fast neutron radiography

    International Nuclear Information System (INIS)

    Ambrosi, R. M.; Watterson, J. I. W.

    1999-01-01

    Fast neutron radiography as a method for non destructive testing is a fast growing field of research. At the Schonland Research Center for Nuclear Sciences we have been engaged in the formulation of a model for the physics of image formation in fast neutron radiography (FNR). This involves examining all the various factors that affect image formation in FNR by experimental and Monte Carlo methods. One of the major problems in the development of a model for fast neutron radiography is the determination of the factors that affect image contrast and resolution. Monte Carlo methods offer an ideal tool for the determination of the origin of many of these factors. In previous work the focus of these methods has been the determination of the scattered neutron field in both a scintillator and a fast neutron radiography facility. As an extension of this work MCNP has been used to evaluate the role neutron scattering in a specimen plays in image detectability. Image processing of fast neutron radiographs is a necessary method of enhancing the detectability of features in an image. MCNP has been used to determine the part it can play in indirectly improving image resolution and aiding in image processing. The role noise plays in fast neutron radiography and its impact on image reconstruction has been evaluated. All these factors aid in the development of a model describing the relationship between contrast, resolution and detectability

  20. A picture of radiography education across Europe

    International Nuclear Information System (INIS)

    McNulty, J.P.; Rainford, L.; Bezzina, P.; Henner, A.; Kukkes, T.; Pronk-Larive, D.; Vandulek, C.

    2016-01-01

    Purpose: To establish an understanding of radiography education across Europe by surveying higher education institutions registered as affiliate members of the European Federation of Radiography Societies (EFRS). Method: An online survey was developed to ascertain data on: curricula, duration, credit load, accreditation requirements, staff qualifications, staff and student exchange opportunities, and availability of postgraduate programmes. Responses were identifiable in terms of educational institution and country. All 46 affiliated educational institutions were invited to participate in the survey. Descriptive and thematic analyses are reported. Results: A response rate of 89.1% (n = 41) was achieved from educational institutions representing 21 countries. The majority of institutions (63.4%) offer a combined Medical Imaging, Radiotherapy and Nuclear Medicine programme; dedicated Medical Imaging programmes are offered by 14 institutions (34.2%); dedicated Radiotherapy programme by one institution (2.4%), and a dedicated Nuclear Medicine programme by only three institutions (6.5%). The Bologna (Bachelor) cycle has been adopted by 90.2% of responding institutions. The majority of institutions (53.7%) indicated programmes of 3 years in duration, others stated 3.5–4 years. Only 14.6% of institutions require ‘International Level’ accreditation for the Bachelors radiography programme. Postgraduate programmes were not offered by 26.8% of institutions and a deficit in Doctoral status for radiography educators was identified. Conclusions: The Bologna (Bachelor) cycle for radiography education has been adopted across the majority of institutions, however, full alignment remains a priority. Postgraduate radiography education opportunities across Europe appear to be insufficient and further investigation of radiography accreditation processes is justified to ensure harmonisation of practice. - Highlights: • The majority of institutions are compliant with the

  1. New concepts in thorax-radiography

    International Nuclear Information System (INIS)

    Biebesheimer, V.; Buchmann, F.

    1987-01-01

    New requirements in thorax-radiography like economy and low patient-dose, are of increasing importance. Using new concepts, these requirements together with high image-quality were fulfilled in a new thorax-system, the pulmo DIAGNOST 100. This was possible by the utilization of the slit-radiography principle together with a linear image intensifier. It resulted in superior quality for the fully automated system. (orig.) [de

  2. Gadolinium sheet converter for neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lima, C.T.S. [Laboratorio de Neutrongrafia em Tempo Real (LNRTR/PEN/COPPE), Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21941-972 Rio de Janeiro, RJ (Brazil); Crispim, V.R. [Laboratorio de Neutrongrafia em Tempo Real (LNRTR/PEN/COPPE), Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21941-972 Rio de Janeiro, RJ (Brazil); PEN/COPPE-DNC/Escola Politecnica CT, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21941-972 Rio de Janeiro, RJ (Brazil)], E-mail: verginia@con.ufrj.br; Santos, W.M.S. [Laboratorio de Colisao Atomica e Molecular (LACAM/IF), Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68528, 21941-972 Rio de Janeiro, RJ (Brazil)

    2007-12-15

    This work describes a methodology developed for the confection of gadolinium sheet converter for neutron radiography using the gadolinium chloride (GdCl{sub 3}) as material converter. Though manufactured at a relatively low cost, they are as good as the sheet converter on the market. Here, we present neutron radiography of the penetrameter, the edge spread function, the modulation transfer function and characteristic curves for each set sheet-AA400 Kodak film.

  3. Corrosion Inhibitors as Penetrant Dyes for Radiography

    Science.gov (United States)

    Novak, Howard L.; Hall, Phillip B.

    2003-01-01

    Liquid/vapor-phase corrosion inhibitors (LVCIs) have been found to be additionally useful as penetrant dyes for neutron radiography (and perhaps also x-radiography). Enhancement of radiographic contrasts by use of LVCIs can reveal cracks, corrosion, and other defects that may be undetectable by ultrasonic inspection, that are hidden from direct optical inspection, and/or that are difficult or impossible to detect in radiographs made without dyes.

  4. Diagnostic radiography: A study in distancing

    International Nuclear Information System (INIS)

    Reeves, Pauline J.; Decker, Sola

    2012-01-01

    Aims: This article aims to explore the ways in which diagnostic radiographers use distancing as a tool for emotional management in radiography practice. Methods: This review utilises data from oral history interviews undertaken as part of a larger study documenting the oral history of the diagnostic radiography profession in the United Kingdom as recounted by 24 participants. Results: The results are presented as illustrative of various aspects of the role of the diagnostic radiographer including the initial choice of diagnostic radiography as a profession, the endemic use of particular terminology, the nature of the encounter in diagnostic radiography (including that of sectional imaging) and whether the role is really patient-centred. Conclusions: The article concludes by suggesting that distancing from the patient is mediated by the need for physical touch in order to position the patient for radiography and also makes the suggestion that those opting for diagnostic radiography as a career may do so because they want a profession which is more distanced from the patient and that, even where this is not the case initially, individuals are socialised into adopting the ‘feeling rules’ of the profession. The article concludes by outlining potential areas for further research.

  5. [Thoracic radiography as routine within cardiological diagnosis?].

    Science.gov (United States)

    Häuber, B; Göhring, S; Reifart, N

    1997-03-27

    As chest radiography is still frequently used routinely in patients suspected of heart disease, the study was undertaken prospectively to assess its value in view of the potentials of modern noninvasive methods. History, physical examination, electrocardiography, ergometry, echocardiography and colour Doppler echocardiography as well as chest radiography were undertaken in 201 consecutive patients (113 men, 88 women, age 60 [3-88] years) with known or suspected cardiac valvular defects or heart failure. Subsequently invasive investigations were performed in 92 of these patients. The value of chest radiography depended on the nature and severity of the particular cardiac disease. The diagnosis was established without chest radiography in all defects (40 patients) of grade III or IV (New York Heart Association) or NYHA class III or IV heart failure (30 patients). Chest radiography provided no additional prognostic or therapeutic information. These data indicate that routine chest radiography is of no value as a screening method in patients with chronic heart failure or cardiac defects, except in a few clearly defined specific circumstances.

  6. Research ambient air industrial hygiene survey of the Pittsburgh Energy Technology Center at Bruceton, Pennsylvania. Final report, April 15--August 30, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Speicher, H.W.; Kretchman, K.W.

    1978-01-01

    This ambient air industrial hygiene evaluation was made in six selected process areas at the Pittsburgh Energy Technology Center on April 15--August 30, 1978. Personal and area sampling for predetermined dusts, vapors, gases and fumes was conducted with NIOSH approved equipment and procedures. The sample analyses were performed at the Industrial Health Foundation's AIHA accredited Analytical Laboratory. The results, reported as time-weighted average concentrations during the sampling period, indicate compliance with the present OSHA permissible values except for benzene concentrations in both laboratory areas. The present benzene TLV was exceeded on one occasion in each of the laboratory areas. These results indicate a need for periodic monitoring of both areas. Recommendations involve additional local exhaust ventilation, adjustable hood windows and periodic benzene sampling.

  7. Current radiography and tomography applications at Necsa and an envisaged upgrade towards a proposed South African national centre for radiography and tomography (SANCRAT)

    Energy Technology Data Exchange (ETDEWEB)

    Radebe, M.J.; De Beer, F.C. [Necsa - South African Nuclear Energy Corporation Limited, P. O.Box 582, Pretoria, 0001 (South Africa)

    2008-07-01

    An upgrade of the current Radiography and Tomography Research facilities is envisaged to enhance the group's support for Necsa's mission to undertake and support nuclear research and utilize penetrating radiation for the benefit of mankind. It is envisage that the SANCRAT will host neutron-, X-ray- and gamma ray penetrating radiation imaging infrastructures that can be utilized by researchers from industry as well as post graduate students from higher educational institutions. Modelling for the upgrade to a multifunctional neutron radiography and tomography facility has been underway. Upgrade plans and implementation has also begun for a 250 kV X-ray radiography set-up, that will exist independent from the neutron facility. Future expansion entails catering for a micro-focus X-ray -, and gamma ray radiography and tomography facilities. The current facilities available consist of one infrastructure facility based on two sources of penetrating radiation, i.e. SAFARI-1 research nuclear reactor as thermal neutron source and a 100 kV X-ray generator. This facility, which hosts the only operational neutron tomography R and D facility in the Southern Hemisphere and in Africa, are being extensively utilized by post graduate students and industry. The facility sees application in a wide range of scientific and engineering disciplines, amongst which is nuclear, geosciences, palaeontology, civil, mechanical, chemical, etc. This paper focus on case studies engaged at the current radiography and tomography facilities over the past 2 years as well as describing the envisaged upgrade initiatives to a fully equipped national centre. (authors)

  8. Current radiography and tomography applications at Necsa and an envisaged upgrade towards a proposed South African national centre for radiography and tomography (SANCRAT)

    International Nuclear Information System (INIS)

    Radebe, M.J.; De Beer, F.C.

    2008-01-01

    An upgrade of the current Radiography and Tomography Research facilities is envisaged to enhance the group's support for Necsa's mission to undertake and support nuclear research and utilize penetrating radiation for the benefit of mankind. It is envisage that the SANCRAT will host neutron-, X-ray- and gamma ray penetrating radiation imaging infrastructures that can be utilized by researchers from industry as well as post graduate students from higher educational institutions. Modelling for the upgrade to a multifunctional neutron radiography and tomography facility has been underway. Upgrade plans and implementation has also begun for a 250 kV X-ray radiography set-up, that will exist independent from the neutron facility. Future expansion entails catering for a micro-focus X-ray -, and gamma ray radiography and tomography facilities. The current facilities available consist of one infrastructure facility based on two sources of penetrating radiation, i.e. SAFARI-1 research nuclear reactor as thermal neutron source and a 100 kV X-ray generator. This facility, which hosts the only operational neutron tomography R and D facility in the Southern Hemisphere and in Africa, are being extensively utilized by post graduate students and industry. The facility sees application in a wide range of scientific and engineering disciplines, amongst which is nuclear, geosciences, palaeontology, civil, mechanical, chemical, etc. This paper focus on case studies engaged at the current radiography and tomography facilities over the past 2 years as well as describing the envisaged upgrade initiatives to a fully equipped national centre. (authors)

  9. Specialism in radiography - a contemporary history of diagnostic radiography

    International Nuclear Information System (INIS)

    Ferris, Christine

    2009-01-01

    Aim and method: Specialism is relative comparing the unusual to a norm. Origins of radiographers' perceptions of what is a specialism are identified. Semi-structured interviews were conducted with 21 practitioners and 10 leading voices whose combined practice span 1932-2001. Findings: Findings show that the exclusive nature of practice is influential on what is perceived as a specialism. Radiographers held career aspirations that included greater recognition, clinical involvement, autonomy and challenging work. Career aspirations were clinical rather than managerial and extended across modality boundaries. A key barrier to career progression was inequality of opportunity as local medical career requirements were dominant. Characteristics of specialism of diagnostic radiography are identified. Factors influencing the formation of specialism are also identified. Summary: Specialisation was dominant but not necessarily constructive to career progression or additional autonomy. Specialism relates to new areas of practice and is facilitated by service need, clear practice boundaries, visionary management, medical support, role development leading to increased autonomy and additional training and education.

  10. Digital radiography versus conventional radiography during excretory urography: our experience

    International Nuclear Information System (INIS)

    Cervi, P.M.; Bighi, S.; Merlo, L.; Lupi, L.; Vita, G.

    1990-01-01

    The authors describe a computed radiographic system employed to generate and archive digital images in intravenous urography. For each exposure the system produces two digital images: the first (left image) simulates a conventional screen-film radiograph, the second (right image); enhances some spatial frequencies and emphasizes the margins of the structures. These images can be modified in their chief parameters and then printed by a laser-printer and archived on optical disks. Four experienced radiologists evaluated digital images with regard to some chief diagnostic parameters and, in 50 patients, they compared digital images with conventional screen-film radiographs and submitted the results to statistical analysis. For some of the chosen parameters, particularly for the evaluation of renal margins before and after contrast medium injection, digital images gave statistically better results than conventional films, while, no statistically significant different was observed for the other parameters. From the results of this preliminary study digital radiography was found to be useful in intravenous urography by reducing the patient's exposition dose, by always obtaining images of good quality, and by enhancing some particular features of the standard image; on the other hand there were many unsolved problems regarding the communicating and archiving system (PACS), because of the slowness of the image transfer procedure, difficulties in data transmission and complexity of referential procedures

  11. External validation of the New Orleans Criteria (NOC), the Canadian CT Head Rule (CCHR) and the National Emergency X-Radiography Utilization Study II (NEXUS II) for CT scanning in pediatric patients with minor head injury in a non-trauma center

    Energy Technology Data Exchange (ETDEWEB)

    Schachar, Jennifer L. [Albert Einstein College of Medicine, Department of Radiology, Bronx, NY (United States); Zampolin, Richard L.; Miller, Todd S.; Farinhas, Joaquim M.; Taragin, Benjamin H. [Albert Einstein College of Medicine and Montefiore Medical Center, Department of Radiology, Bronx, NY (United States); Freeman, Katherine [Albert Einstein College of Medicine and Montefiore Medical Center, Department of Biostatistics, Bronx, NY (United States)

    2011-08-15

    Head CT scans are considered the imaging modality of choice to screen patients with head trauma for neurocranial injuries; however, widespread CT imaging is not recommended and much research has been conducted to establish objective clinical predictors of intracranial injury (ICI) in order to optimize the use of neuroimaging in children with minor head trauma. To evaluate whether a strict application of the New Orleans Criteria (NOC), Canadian CT Head Rule (CCHR) and National Emergency X-Radiography Utilization Study II (NEXUS II) in pediatric patients with head trauma presenting to a non-trauma center (level II) could reduce the number of cranial CT scans performed without missing clinically significant ICI. We conducted an IRB-approved retrospective analysis of pediatric patients with head trauma who received a cranial CT scan between Jan. 1, 2001, and Sept. 1, 2008, and identified which patients would have required a scan based on the criteria of the above listed decision instruments. We then determined the sensitivities, specificities and negative predictive values of these aids. In our cohort of 2,101 patients, 92 (4.4%) had positive head CT findings. The sensitivities for the NOC, CCHR and NEXUS II were 96.7% (95%CI 93.1-100), 65.2% (95%CI 55.5-74.9) and 78.3% (95%CI 69.9-86.7), respectively, and their negative predictive values were 98.7%, 97.6% and 97.2%, respectively. In contrast, the specificities for these aids were 11.2% (95%CI 9.8-12.6), 64.2% (95%CI 62.1-66.3) and 34.2% (95%CI 32.1-36.3), respectively. Therefore, in our population it would have been possible to scan at least 10.9% fewer patients. The number of cranial CT scans conducted in our pediatric cohort with head trauma would have been reduced had any of the three clinical decision aids been applied. Therefore, we recommend that further validation and adoption of pediatric head CT decision aids in non-trauma centers be considered to ultimately increase patient safety while reducing medical

  12. Thorium-uranium fission radiography

    Science.gov (United States)

    Haines, E. L.; Weiss, J. R.; Burnett, D. S.; Woolum, D. S.

    1976-01-01

    Results are described for studies designed to develop routine methods for in-situ measurement of the abundance of Th and U on a microscale in heterogeneous samples, especially rocks, using the secondary high-energy neutron flux developed when the 650 MeV proton beam of an accelerator is stopped in a 42 x 42 cm diam Cu cylinder. Irradiations were performed at three different locations in a rabbit tube in the beam stop area, and thick metal foils of Bi, Th, and natural U as well as polished silicate glasses of known U and Th contents were used as targets and were placed in contact with mica which served as a fission track detector. In many cases both bare and Cd-covered detectors were exposed. The exposed mica samples were etched in 48% HF and the fission tracks counted by conventional transmitted light microscopy. Relative fission cross sections are examined, along with absolute Th track production rates, interaction tracks, and a comparison of measured and calculated fission rates. The practicality of fast neutron radiography revealed by experiments to data is discussed primarily for Th/U measurements, and mixtures of other fissionable nuclei are briefly considered.

  13. Interprofessional working in diagnostic radiography

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.; Day, Jane

    2014-01-01

    This paper considers interprofessional working within one diagnostic imaging department. The literature is still divided about the long-term impact of interprofessional learning in pre-registration health and social care education, and its impact on the quality of care provided. When reading the literature about interprofessional working the main topics considered by other authors are team working, communication between professionals, stereotyping and tribalism. The results presented are from an ethnographic study in one department with participant observation and semi-structured interviews. The three main aspects discussed in this paper are; tribalism and culture within the diagnostic radiography profession, communication between different professional groups, and a lack of understanding of the roles of other professional groups. It was evident from the results of this study that tribalism and culture, and a lack of understanding were significant barriers to interprofessional working. It was felt by the authors that pre-registration and post-registration interprofessional education could be significant in changing the culture of the NHS in the future as more professionals learn from and about one another

  14. Radiography of the equine stomach

    International Nuclear Information System (INIS)

    Dik, K.J.; Kalsbeek, H.C.

    1985-01-01

    To obtain radiographic information concerning the equine stomach, a gastrographic contrast examination is required. This study describes this procedure in detail. A powerful radiographic unit, the tubehead linked to an image intensifier and suspended by an electromechanical overhead gantry system, is required. To obtain accurately positioned radiographs during the fluoroscopic examination, a cassette holder with a stationary grid is mounted at the entrance window of the image intensifier. The examination is performed in the unsedated standing horse after 24 hours of starvation, using a combination of survey radiography and fluoroscopic viewing after the inflation of air, followed by the administration of barium sulphate suspension by stomach tube. The gastrographic contrast examination is performed in three experimental animals and 23 abnormal horses. Pneumogastrophy appeared to be valuable to diagnose gastric tumors, to differentiate between gastric tumors and other masses in the cranial abdomen, and to visualize gastric parasites, even in large horses. The use of barium sulphate suspension does not result in an adequate double contrast of the stomach, but it may aid to diagnose esophagogastric or pyloric stenosis and gastric or duodenal ulcers

  15. Industrial Analytics Corporation

    Energy Technology Data Exchange (ETDEWEB)

    Industrial Analytics Corporation

    2004-01-30

    The lost foam casting process is sensitive to the properties of the EPS patterns used for the casting operation. In this project Industrial Analytics Corporation (IAC) has developed a new low voltage x-ray instrument for x-ray radiography of very low mass EPS patterns. IAC has also developed a transmitted visible light method for characterizing the properties of EPS patterns. The systems developed are also applicable to other low density materials including graphite foams.

  16. Automatic defect detection: various uses of a reference radiograph; Detection automatique de defauts: des differents usages d'une radiographie de reference

    Energy Technology Data Exchange (ETDEWEB)

    Rebuffel, V

    2005-07-01

    Defects detection in radiography can be done by a pixel by pixel comparison with a reference radiography made on a fault-less part. However, because of the parts complexness, an a priori knowledge is necessary which must be supplied by several reference radiographies and different image processing methods. This presentation emphasizes the adequation of the different existing methods with the characteristics of the problems under study and analyzes several methods developed and tested at the laboratory for precise industrial purposes. Abstract only. (J.S.)

  17. Environmental Analysis of The Impacts of Batik Waste Water Polution on The Quality of Dug Well Water in The Batik Industrial Center of Jenggot Pekalongan City

    Directory of Open Access Journals (Sweden)

    Budiyanto Slamet

    2018-01-01

    Full Text Available The city of Pekalongan known as "Kota Batik" is one of Batik Industrial Centers in Indonesia with 917 batik industry. There are 203 batik industries located in Jenggot Village, which is the biggest batik industrial center in Pekalongan City. The process of making batik requires a dye derived from synthetic dyes containing heavy metals. Most of the waste is directly discharged into the environment without going through the processing first. This is due to the lack of optimal management of existing WWTP as well as lack of public awareness of environmental conservation. This condition has a negative impact on the surrounding community, especially in terms of environmental health. The result of measurement of 5 (five batik industrial waste outlets and 5 point of batik waste water in residential sewer shows almost equal number for 3 (three parameters of heavy metals Cd, Cr and Pb with average number: Cd 0.07 Mg / L, Cr 0.76 mg / L and Pb 0.78 mg / L. These three parameters exceed the maximum level of quality standard established by Government Regulation No.82 of 2001 on Water Quality Management and Water Pollution Control. The average result of the water quality measurement of the well digging population to the heavy metal content are: Cd 0,001 mg / L, Cr 0,002 mg / L and Pb 0.04 mg / L. Of the three parameters of heavy metals, heavy metals of Pb are on average higher than the maximum level of quality standards established by Decree of the Minister of Health Number. 492 / Menkes / Per / IV / 2010 regarding Water Quality Requirements. Potential occurrence of dug well water contamination due to infiltration of batik waste water is big enough. Survey results of 15 dug wells show that the construction of dug wells is not sufficient. There is a dug well with a damaged outer wall of 16.1%, damaged inner wall of 17.9% and a damaged well floor of 19.7%. Improper well construction impacts on the infiltration of batik waste water into the well. Survey results

  18. Dose assessment in panoramic dental radiography

    International Nuclear Information System (INIS)

    Novak, L.

    2005-01-01

    In this paper author deals with the problem of dosimetry at panoramic radiography. Panoramic radiography is a rather complex technique, based on the simultaneous movement of an X-ray tube and an image receptor. A panoramic exposure is acquired by rotating the x-ray tube in an arc around the patients jaw. A thin X-ray beam oriented perpendicular to direction of the motion passes through the jaws at a slight upward angulation with respect to the occlusal plane. Due to this geometry of an examination, it is not straightforward, how to express a dose delivered to a patient during the examination. Because of a similarity with CT examinations, a dose descriptor product of kerma and length PKL is used in panoramic radiology also. However, the way of measurement is different. Currently, no dose descriptor in panoramic radiography is measured in the Czech Republic during the quality control measurements. Therefore, it would be appropriate to accept the product of kerma and length as a standard dose descriptor for panoramic radiography. This measurement should be included in QC procedures as well. Methods of dosimetry at panoramic radiography are discussed. (author)

  19. Algorithm for optimisation of paediatric chest radiography

    International Nuclear Information System (INIS)

    Kostova-Lefterova, D.

    2016-01-01

    The purpose of this work is to assess the current practice and patient doses in paediatric chest radiography in a large university hospital. The X-ray unit is used in the paediatric department for respiratory diseases. Another purpose was to recommend and apply optimized protocols to reduce patient dose while maintaining diagnostic image quality for the x-ray images. The practice of two different radiographers was studied. The results were compared with the existing practice in paediatric chest radiography and the opportunities for optimization were identified in order to reduce patient doses. A methodology was developed for optimization of the x-ray examinations by grouping children in age groups or according to other appropriate indication and creating an algorithm for proper selection of the exposure parameters for each group. The algorithm for the optimisation of paediatric chest radiography reduced patient doses (PKA, organ dose, effective dose) between 1.5 and 6 times for the different age groups, the average glandular dose up to 10 times and the dose for the lung between 2 and 5 times. The resulting X-ray images were of good diagnostic quality. The subjectivity in the choice of exposure parameters was reduced and standardization has been achieved in the work of the radiographers. The role of the radiologist, the medical physicist and radiographer in the process of optimization was shown. It was proven the effect of teamwork in reducing patient doses at keeping adequate image quality. Key words: Chest Radiography. Paediatric Radiography. Optimization. Radiation Exposure. Radiation Protection

  20. Muon radiography for exploration of Mars geology

    Directory of Open Access Journals (Sweden)

    S. Kedar

    2013-06-01

    Full Text Available Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays to image the interior of large-scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  1. National reference doses for dental cephalometric radiography.

    Science.gov (United States)

    Holroyd, J R

    2011-12-01

    Diagnostic reference levels (DRLs) are an important tool in the optimisation of clinical radiography. Although national DRLs are provided for many diagnostic procedures including dental intra-oral radiography, there are currently no national DRLs set for cephalometric radiography. In the absence of formal national DRLs, the Health Protection Agency (HPA) has previously published National Reference Doses (NRDs) covering a wide range of diagnostic X-ray examinations. The aim of this study was to determine provisional NRDs for cephalometric radiography. Measurements made by the Dental X-ray Protection Service (DXPS) of the HPA, as part of the cephalometric X-ray equipment testing service provided to dentists and dental trade companies throughout the UK, were used to derive provisional NRDs. Dose-area product measurements were made on 42 X-ray sets. Third quartile dose-area product values for adult and child lateral cephalometric radiography were found to be 41 mGy cm² and 25 mGy cm², respectively, with individual measurements ranging from 3 mGy cm² to 108 mGy cm². This report proposes provisional NRDs of 40 mGy cm² and 25 mGy cm² for adult and child lateral cephalometric radiographs, respectively; these doses could be considered by employers when establishing their local DRLs.

  2. Collaboration in radiography: A bibliometric analysis

    International Nuclear Information System (INIS)

    Snaith, Beverly

    2012-01-01

    Introduction: Increasing research activity is an aim of the radiography profession, but there is a lack of knowledge of how this can be achieved. Collaboration between clinical and academic centres as well as between individuals has increased productivity in other professions and has been suggested as a strategy for radiography. This bibliometric study maps the current contribution to the radiography evidence base through a single journal. Method: All articles published in Radiography from 1997 to 2011 were reviewed to identify collaboration trends together with article type and subject. Analysis also enabled comparison of research and publication patterns. Results: 706 articles were published by 1205 individual authors. 63.0% were written by UK based authors, although this varied over time. Over 80% of authors published only single article. Two thirds of articles were collaborative with an increase in clinical-academic co-authorship over the 15 years of the study. Although the majority of articles were diagnostic imaging based, the pattern mirrors the UK workforce profile. Clinicians, including clinical-academic co-authors, tend to write about clinical practice and roles, whereas academics write about a broader range of topics. Conclusions: There has been a growth in research and scholarship within the UK radiography journal and both clinical and academic radiographers are contributing to the evidence base through increased collaboration.

  3. Review of neutron radiographic applications in industrial and biological systems

    International Nuclear Information System (INIS)

    Ashraf, M.M.; Khan, A.R.

    1992-10-01

    Neutron radiography is a non-destructive testing technique and is being used worldwide for the design and the development of reactor fuels for research and power reactors. It is also being used for non-destructive examination of nuclear industrial products. In addition to its explosives and other industrial sectors. In addition to its applications in industrial sectors, the technique is widely used for research and development activities in biological systems. A review of technical applications of neutron radiography in different fields particularly in nuclear fuel management, aerospace industry, explosives and biology is presented. The methodology of neutron radiography is also discussed in detail along with the advantages of the technique. In addition, the potential of the neutron radiography facility at PINSTECH has been described. (author)

  4. Muon radiography method for fundamental and applied research

    Science.gov (United States)

    Alexandrov, A. B.; Vladymyrov, M. S.; Galkin, V. I.; Goncharova, L. A.; Grachev, V. M.; Vasina, S. G.; Konovalova, N. S.; Malovichko, A. A.; Managadze, A. K.; Okat'eva, N. M.; Polukhina, N. G.; Roganova, T. M.; Starkov, N. I.; Tioukov, V. E.; Chernyavsky, M. M.; Shchedrina, T. V.

    2017-12-01

    This paper focuses on the basic principles of the muon radiography method, reviews the major muon radiography experiments, and presents the first results in Russia obtained by the authors using this method based on emulsion track detectors.

  5. DETECTION OF LACK OF FUSION WELD DEFECTS BY RADIOGRAPHY

    International Nuclear Information System (INIS)

    Souza, M. P.; Almeida, R. M.; Rebello, J. M. A.; Soares, S. D.

    2009-01-01

    In this work, radiography was employed as the NDT technique for detection of flaws in circumferential girth welds of steel pipelines used in offshore installations in the petroleum industry. The kind of defect specifically focused was lack of fusion. It is currently accepted in the literature that radiography is not as sensitive as ultrasonics to detect lack of fusion defects. Unfortunately, the radiographic inspection can barely detect lack of fusion and only when it is associated to inclusions and voids of considerable size. However, in a previous article ('Reliability of radiographic inspection of steel pipeline girth welds', QNDE Conference, 2007), the authors showed that it is possible to detect lack of fusion defects if, in the radiographic tests, the angle of incidence is the same angle that the weld bevel makes with the test piece surface, which means lowering the angle of disorientation between the flaw and the radiographic beam. However, no concerns were made to sizing the defects. Computational simulation was used with XRSIM software to establish the optimal radiographic parameters to reach the lower limit for detection for this kind of defect.

  6. Radiation shielding in dental radiography.

    Science.gov (United States)

    Stenström, B; Rehnmark-Larsson, S; Julin, P; Richter, S

    1983-01-01

    The protective effect in the thyroid region from different types of radiation shielding at intraoral radiography has been studied as well as the reduction of the absorbed dose to the sternal and the gonadal regions. The shielding tested were the different types of leaded aprons, of which three had an attached leaded collar and the other two were used in combination with separate soft leaded collars. Furthermore one of the soft leaded collars and an unflexible horizontal leaded shield were tested separately. Two dental x-ray machines of 60 and 65 kVp with rectangular and circular tube collimators were used. The exposure times corresponded to speed group E film. The absorbed doses were measured with two ionization chambers. No significant difference in the protective effect in the thyroid gland could be found between the different types of radiation shieldings. There was a dose reduction by approximately a factor of 2 to the thyroid region down to 0.08 mGy per full survey using parallelling technique, and below 0.001 mGy per single bitewing exposure. The shielding reduced the thyroid dose using bisecting-angle technique by a factor of 5 down to 0.15 mGy per full survey (20 exposures). In the sternal region the combinations of apron and collar reduced the absorbed dose from a full survey to below 2 microGy compared with 18 microGy (parallelling) and 31 microGy (bisecting-angle) without any shielding. With the horizontal leaded shield a reduction by a factor of 6 was obtained, but no significant sternal dose reduction could be detected from the soft collar alone. The gonadal dose could be reduced by a factor of 10 with the horizontal leaded shield, parallelling technique and circular collimator. Using leaded aprons the gonadal was approximately one per cent of the dose without any shielding, i.e. below 0.01 microGy per single intraoral exposure.

  7. Radiation shielding in dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Stenstroem, B.; Rehnmark-Larsson, S.; Julin, P.; Richter, S.

    1983-01-01

    The protective effect in the thyroid region from different types of radiation shieldings at intraoral radiography has been studied as well as the reduction of the absorbed dose to the sternal and the gonadal regions. The shieldings tested were five different types of leaded aprons, of which three had an attached leaded collar and the other two were used in combination with separate soft leaded collars. Furthermore one of the soft leaded collars and an unflexible horizontal leaded shield were tested separately. Two dental x-ray machines of 60 and 65 kVp with rectangular and circular tube collimators were used. The exposure time corresponded to speed group E film. The absorbed doses were measured with two ionization chambers. No significant difference in the protective effect in the thyroid gland could be found between the different types of radiation shieldings. There was a dose reduction by approximately a factor of 2 to the thyroid region down to 0.08 mGy per full survey using parallelling technique, and below 0.001 mGy per single bitewing exposure. The shieldings reduced the thyroid dose using bisecting-angle technique by a factor of 5 down to 0.15 mGy per full survey (20 exposures). In the sternal region the combinations of apron and collar reduced the absorbed dose from a full survey to below 2 ..mu..Gy compared with 18 ..mu..Gy (parallelling) and 31 ..mu..Gy (biscting-angle) without any shielding. With the horizontal leaded shield a reduction by a factor of 6 was obtained but no significant sternal dose reduction could be detected from the soft collar alone. The gonadal dose could be reduced by a factor of 10 with the horizontal leaded shield, parallelling technique and circular collimator. Using leaded aprons the gonadal dose was approximately one per cent of the dose without any shielding, i.e. below 0.01 ..mu..Gy per single intraoral exposure.

  8. Radiation shielding in dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Stenstroem, B.; Rehnmark-Larsson, S.; Julin, P.; Richter, S.

    1984-01-01

    The protective effect in the thyroid region from different types of radiation shieldings at intraoral radiography has been studied as well as the reduction of the absorbed dose to the sternal and the gonadal regions. The shieldings tested were five different types of leaded aprons, of which three had an attached leaded collar and the other two were used in combination with separate soft leaded collars. Furthermore one of the soft leaded collars and an unflexible horizontal leaded shield were tested separately. Two dental x-ray machines of 60 and 65 kVp with rectangular and circular tube collimators were used. The exposure time corresponded to speed group E film. The absorbed doses were measured with two ionization chambers. No significant difference in the protective effect in the thyroid gland could be found between the different types of radiation shieldings. There was a dose reduction by approximately a factor of 2 to the thyroid region down to 0.08 mGy per full survey using parallelling technique, and below 0.001 mGy per single bitewing exposure. The shieldings reduced the thyroid dose using bisecting-angle technique by a factor of 5 down to 0.15 mGy per full survey. In the sternal region the combinations of apron and collar reduced the absorbed dose from a full survey to below 2 ..mu..Gy compared with 18 ..mu..Gy (parallelling) and 31 ..mu..Gy (biscting-angle) without any shielding. With the horizontal leaded shield a reduction by a factor of 6 was obtained but no significant sternal dose reduction could be detected from the soft collar alone. The gonadal dose could be reduced by a factor of 10 with the horizontal leaded shield, parallelling technique and circular collimator. Using leaded aprons the gonadal dose was approximately one per cent of the dose without any shielding, i.e. below 0.01 ..mu..Gy per single intraoral exposure.

  9. Clinical application of computed radiography

    International Nuclear Information System (INIS)

    Higashida, Yoshiharu

    1990-01-01

    Observer performance tests were performed to compare the diagnostic accuracy of digitized storage phosphors and conventional radiography in the detection of microcalcification in the breast and pulmonary nodules. Clustered microcalcifications (0.125-0.177 mm, 0.210-0.250 mm) were randomly superimposed on a human breast specimen. Two types of screen-film systems (Toshiba MM6/Fuji MINC, Kodak MinR/Kodak MinR) and CR images either with unsharp mask or with no image processing (unprocess) were used as imaging systems. Nine readers assessed the capability of screen-films, and unsharp-masked and unprocessed mammograms to detect microcalcifications. Observer performance data were evaluated by receiver operating characteristics (ROC) analysis. Both the area under ROC curve and the true positive localization fraction were used as performance indexes. Two screen-film images provided a higher detectability of microcalcifications than CR images. In the detectability of microcalcifications, unsharp-masked images were superior to unprocessed images, with no statistically significant difference. CR images showed higher false positive fraction than screen-film systems. To assess the detectability of pulmonary nodules, 15 radiologists compared the diagnostic accuracy of screen-film system and CR images, including unprocessed, unsharp-masked, reversed and paired images, in 18 normal volunteers and 18 patients with pulmonary nodules. Overall diagnostic accuracy of CR images, except for reversed images, were comparable to the screen-film system. In case of definite, large nodules, unprocessed, unsharp-masked, and paired images were superior to the screen-film and reversed images. Screen-film and unprocessed images were helpful in cases of tiny nodules without definite contrast. The detectability of pulmonary nodules may be affected by image processing conditions, radiologist' experiences, and characteristics of nodules themselves. (N.K.) 59 refs

  10. Practical Uses of Neutron Radiography for Non-Destructive Testing

    International Nuclear Information System (INIS)

    Middleton, M.F.; de Beer, F.; Pazsit, Imre; Li, Kewen; Hilson, Jodie

    2006-01-01

    ). An acknowledged shortcoming of neutron radiography is its inability to identify structural features less than about 10 microns, which is largely a result of current limitations in neutron-image detection media. Many industries, such as the petroleum industry, for example, have been slow to adopt neutron radiography technology, preferring to persist with X-ray CT-scanning techniques, despite some obvious advantages held by neutron radiography. Historically, the principal problem with the slow adoption of neutron radiography, and tomography, appears to be related to (1) a lack of detailed studies demonstrating its power as an analytical technique, and (2) the restriction of neutron testing techniques to nuclear beams at reactors. Neutron radiography can provide a very accurate estimate of hydrogen content in porous media. In terms of non-destructive analysis of porous media, it is convenient to approach quantitative analysis of neutron images using the general rule: I = I 0 e - μρh (1) where I is the incident neutron intensity, I 0 is the transmitted neutron intensity, μ is the neutron attenuation coefficient in g/cm 2 , ρ is the sample density in g/cm 3 and h is the sample thickness (cm) in the direct path of neutron transmission. It has been found in recently reported investigations that equation [1] does not exactly describe the attenuation behaviour of neutrons for relatively large thicknesses of media, which are high neutron scatterers (e.g. hydrogen and hydrogen-rich media like water and oil). Thus, in our experiments, to ensure an accuracy as high as possible in the determination of hydrogen content, we have corrected the neutron transmission for scattering losses by a method suggested by Middleton and de Beer. Porosity of porous media can be derived from neutron images, using a simple extension of equation [1]. Figure 1 shows an hypothetical composite porous medium, consisting of two media (type 1 and type 2). Based on equation [1], equations [2) to [5

  11. Quantitative neutron radiography using neutron absorbing honeycomb

    International Nuclear Information System (INIS)

    Tamaki, Masayoshi; Oda, Masahiro; Takahashi, Kenji; Ohkubo, Kohei; Tasaka, Kanji; Tsuruno, Akira; Matsubayashi, Masahito.

    1993-01-01

    This investigation concerns quantitative neutron radiography and computed tomography by using a neutron absorbing honeycomb collimator. By setting the neutron absorbing honeycomb collimator between object and imaging system, neutrons scattered in the object were absorbed by the honeycomb material and eliminated before coming to the imaging system, but the neutrons which were transmitted the object without interaction could reach the imaging system. The image by purely transmitted neutrons gives the quantitative information. Two honeycombs were prepared with coating of boron nitride and gadolinium oxide and evaluated for the quantitative application. The relation between the neutron total cross section and the attenuation coefficient confirmed that they were in a fairly good agreement. Application to quantitative computed tomography was also successfully conducted. The new neutron radiography method using the neutron-absorbing honeycomb collimator for the elimination of the scattered neutrons improved remarkably the quantitativeness of the neutron radiography and computed tomography. (author)

  12. Thyroid dose distribution in dental radiography

    International Nuclear Information System (INIS)

    Bristow, R.G.; Wood, R.E.; Clark, G.M.

    1989-01-01

    The anatomic position and proven radiosensitivity of the thyroid gland make it an organ of concern in dental radiography. A calibrated thermoluminescent dosimetry system was used to investigate the absorbed dose (microGy) to the thyroid gland resultant from a minimum irradiated volume, intraoral full-mouth radiography technique with the use of rectangular collimation with a lead-backed image receptor, and conventional panoramic radiography performed with front and rear lead aprons. Use of the minimum irradiated volume technique resulted in a significantly decreased absorbed dose over the entire thyroid region ranging from 100% to 350% (p less than 0.05). Because this intraoral technique results in radiographs with greater image quality and also exposes the thyroid gland to less radiation than the panoramic, this technique may be an alternative to the panoramic procedure

  13. Subtraction radiography of interradicular bone lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kullendorf, B.; Groendahl, K.; Rohlin, M.; Nilsson, M. (Lund Univ., Malmoe (Sweden))

    1992-10-01

    Subtraction and conventional radiography were evaluated for their diagnostic potential to assess interradicular bone lesions in the mandibular premolar region. Both conventional radiographs and subtraction images were interpreted by 10 observers. The receiver-operating characteristic technique was used to compare the two techniques. The diagnostic validity was higher for the subtraction technique, both for lesions confined to cancellous bone and for lesions including the cortical bone, than for the conventional technique. For bone defects confined to cancellous bone the diagnostic accuracy was lower than those reported from periapical bone lesion irrespective of whether subtraction or conventional radiography was used. It is concluded that subtraction radiography improves the detectability of bone lesions, shallow ones in particular. Lesions in the interradicular bone are more difficult to detect than those in the periapical bone. 26 refs., 3 figs., 2 tabs.

  14. Subtraction radiography of interradicular bone lesions

    International Nuclear Information System (INIS)

    Kullendorf, B.; Groendahl, K.; Rohlin, M.; Nilsson, M.

    1992-01-01

    Subtraction and conventional radiography were evaluated for their diagnostic potential to assess interradicular bone lesions in the mandibular premolar region. Both conventional radiographs and subtraction images were interpreted by 10 observers. The receiver-operating characteristic technique was used to compare the two techniques. The diagnostic validity was higher for the subtraction technique, both for lesions confined to cancellous bone and for lesions including the cortical bone, than for the conventional technique. For bone defects confined to cancellous bone the diagnostic accuracy was lower than those reported from periapical bone lesion irrespective of whether subtraction or conventional radiography was used. It is concluded that subtraction radiography improves the detectability of bone lesions, shallow ones in particular. Lesions in the interradicular bone are more difficult to detect than those in the periapical bone. 26 refs., 3 figs., 2 tabs

  15. Problems associated with veterinary dental radiography

    International Nuclear Information System (INIS)

    Eisner, E.R.

    1990-01-01

    Veterinarians have been radiographing animal skulls for many years, but sophisticated dentistry was not widely used until the 1970s. Elevated awareness of veterinary dental techniques has led to the need for producing accurate radiographic images of the teeth and periodontal structures. Many problems arise for the clinician who treats small animals who has, before this time, radiographed the skull of dogs and cats solely for the purpose of assessing neoplastic, infectious, or traumatic disease of the mandible, maxilla, or calvarium and now desires to perform dental radiography. This chapter will describe the advantages and disadvantages of some of the more common types of radiographic equipment and supplies, discuss extraoral and intraoral radiographic positioning and technique, identify anatomic landmarks and diagnostic features of intraoral radiography, and offer suggestions concerning the art of using dental radiography in veterinary practice

  16. Low material budget floating strip Micromegas for ion transmission radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, J., E-mail: jonathan.bortfeldt@cern.ch [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Biebel, O.; Flierl, B.; Hertenberger, R.; Klitzner, F.; Lösel, Ph. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Magallanes, L. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); University Hospital Heidelberg, Im Neuenheimer Feld 672, D-69120 Heidelberg (Germany); Müller, R. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Parodi, K. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); Heidelberg Ion-Beam Therapy Center, Im Neuenheimer Feld 450, D-69120 Heidelberg (Germany); Schlüter, T. [LMU Munich, Excellence Cluster Universe, Boltzmannstr. 2, D-85748 Garching (Germany); Voss, B. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstr. 1, D-64291 Darmstadt (Germany); Zibell, A. [JMU Würzburg, Sanderring 2, D-97070 Würzburg (Germany)

    2017-02-11

    Floating strip Micromegas are high-accuracy and discharge insensitive gaseous detectors, able to track single particles at fluxes of 7 MHz/cm{sup 2} with 100 μm resolution. We developed low-material-budget detectors with one-dimensional strip readout, suitable for tracking at highest particle rates as encountered in medical ion transmission radiography or inner tracker applications. Recently we additionally developed Kapton-based floating strip Micromegas with two-dimensional strip readout, featuring an overall thickness of 0.011 X{sub 0}. These detectors were tested in high-rate proton and carbon-ion beams at the tandem accelerator in Garching and the Heidelberg Ion-Beam Therapy Center, operated with an optimized Ne:CF{sub 4} gas mixture. By coupling the Micromegas detectors to a new scintillator based range detector, ion transmission radiographies of PMMA and tissue-equivalent phantoms were acquired. The range detector with 18 layers is read out via wavelength shifting fibers, coupled to a multi-anode photomultiplier. We present the performance of the Micromegas detectors with respect to timing and single plane track reconstruction using the μTPC method. We discuss the range resolution of the scintillator range telescope and present the image reconstruction capabilities of the combined system.

  17. Assessing the impact of computed radiography and PACS

    International Nuclear Information System (INIS)

    Hedgcock, M.W. Jr.; Kehr, K.

    1989-01-01

    The authors' institution is a VA pilot center for total digital imaging and PACS. They are gathering quantitative service delivery and cost data before, during, and after stepwise implementation of computed radiography and PACS at our institution to define the impact on imaging service delivery. They designed a simple audit method using the X-ray request and time clocks to determine patient waiting time, imaging time, film use, image availability to the radiologist, matching of current with previous images, image availability to clinicians, and time to final interpretation. Their department model is a multichannel, multiserver patient queue. Their current radiograph file is space limited. Their preimplementation audit showed some long waiting times (40 minutes, average 20) and immediate retrieval of prior films in only 42% of cases, with an average retrieval time of 22 hours. Computed radiography and the optical archive have the potential to improve these figures. The audit will be ongoing and automated as implementation of PACS progresses, to measure service improvement and learning curve with the new equipment. This paper presents the audit format and baseline preimplementation figures

  18. Chest radiography: new technological developments and their applications

    NARCIS (Netherlands)

    Schalekamp, S.; Ginneken, B. van; Karssemeijer, N.; Schaefer-Prokop, C.M.

    2014-01-01

    Digital chest radiography is still the most common radiological examination. With the upcoming three-dimensional (3D) acquisition techniques the value of radiography seems to diminish. But because radiography is inexpensive, readily available, and requires very little dose, it is still being used

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... and send a signed report to your primary care or referring physician , who will discuss the results ... widely available in emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... any possibility you are pregnant. Leave jewelry at home and wear loose, comfortable clothing. You may be ... emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it convenient for both ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? A bone x-ray examination itself ... available in emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it convenient ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the patient in a hospital bed or the emergency room. The x-ray tube is connected to ... equipment is relatively inexpensive and widely available in emergency rooms, physician offices, ambulatory care centers, nursing homes ...

  3. Image processing in real time radiography

    International Nuclear Information System (INIS)

    Link, R.; Nuding, W.; Sauevwein, K.; Souw, E.K.

    1985-01-01

    Image processing in real time radiography has become an important feature to improve the detectibility of defects. However, often enough, impressed by the tremendous success of image processing of e.g. evaluation of Landsat pictures, people expect the same or nearly the same effect in NDT applications. The magic word image processing thus results in unrealistic demands to the capability even of highly sophisticated image processing systems. In this paper the possibilities as well as the different tasks of image processing in the field of real time radiography is discussed

  4. Cold neutron radiography using low power accelerator

    International Nuclear Information System (INIS)

    Kiyanagi, Yoshiaki; Iwasa, Hirokatu

    1993-01-01

    A cold neutron source which can be adopted at a low power accelerator was studied. Time-of-flight radiography using the cold neutron source was performed. It is suggested that time-of-flight cold neutron radiography has possibility to distinguish the materials more clearly than the traditional film method since large contrast differences can be obtained by using digital data of the neutron intensity at different energies from thermal to cold region. Material will be identified at the same time by this method. (author)

  5. Shortened processing time technique for color industrial radiography

    Science.gov (United States)

    Lapinski, N. P.

    1969-01-01

    Improved processing method reduces time required to generate a color radiograph. Prior to, or after exposure to penetrating radiation, the emulsion side of the film is flashed to a colored light which produces the hue changes in the processed radiograph. Agitation of the film during processing assures uniformity of results.

  6. Digital image processing in NDT : Application to industrial radiography

    International Nuclear Information System (INIS)

    Aguirre, J.; Gonzales, C.; Pereira, D.

    1988-01-01

    Digital image processing techniques are applied to image enhancement discontinuity detection and characterization is radiographic test. Processing is performed mainly by image histogram modification, edge enhancement, texture and user interactive segmentation. Implementation was achieved in a microcomputer with video image capture system. Results are compared with those obtained through more specialized equipment main frame computers and high precision mechanical scanning digitisers. Procedures are intended as a precious stage for automatic defect detection

  7. Use of X-ray essay and fluoroscopy in the armament industry

    International Nuclear Information System (INIS)

    Bohnsack, G.

    1989-01-01

    Of the nondestructive testing the process of test by radiography has a special place. With view to great variety of problems of essays in the armament industry, the X-Ray radiography has excellent possibilities of testing, that not possible, for example, with ultrasonography. Different possibilities that the X-ray radiography offer to essays of grenade and blasting cap, through practice examples described case to case are presented. (V.R.B.)

  8. Impact of clinical decision support on radiography for acute ankle injuries: a randomized trial

    Directory of Open Access Journals (Sweden)

    Shahein Tajmir

    2017-04-01

    Full Text Available Introduction: While only 15-20% of patients with foot and ankle injuries presenting to urgent care centers have clinically significant fractures, most undergo radiography. We examined the impact of electronic point-of-care clinical decision support (CDS on adherence to the Ottawa Ankle Rules (OAR, as well as use and yield of foot and ankle radiographs in patients with acute ankle injury. Methods: We obtained institutional review board approval for this randomized controlled study performed April 18, 2012—December 15, 2013. All ordering providers credentialed at an urgent care affiliated with a quaternary care academic hospital were randomized to either receive or not receive CDS, based on the OAR and integrated into the physician order-entry system, with feedback at the time of imaging order. If the patient met OAR low-risk criteria, providers were advised against imaging and could either cancel the order or ignore the alert. We identified patients with foot and ankle complaints via ICD-9 billing codes and electronic health records and radiology reports reviewed for those who were eligible. Chi-square was used to compare adherence to the OAR (primary outcome, radiography utilization rate and radiography yield of foot and ankle imaging (secondary outcomes between the intervention and control groups. Results: Of 14,642 patients seen at urgent care during the study period, 613 (4.2%, representing 632 visits presented with acute ankle injury and were eligible for application of the OAR; 374 (59.2% of these were seen by control-group providers. In the intervention group, CDS adherence was higher for both ankle (239/258=92.6% vs. 231/374=61.8%, p=0.02 and foot radiography (209/258=81.0% vs. 238/374=63.6%; p<0.01. However, ankle radiography use was higher in the intervention group (166/258=64.3% vs. 183/374=48.9%; p<0.01, while foot radiography use (141/258=54.6% vs. 202/374=54.0%; p=0.95 was not. Radiography yield was also higher in the intervention

  9. Comparison of the quality of the chest film between digital radiography and conventional high kV radiography

    International Nuclear Information System (INIS)

    Zeng Qingsi; Cen Renli; Chen Ling; He Jianxun; Lin Hanfei

    2003-01-01

    Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography (78.6%, P < 0.001). Conclusion: Direct digital radiography could provide the chest film with better quality than that with the conventional high kV radiography. The direct digital radiography system is easy to operate, fast in capturing imaging and could provide post-processing techniques, which will facilitate the accurate diagnosis of chest radiography

  10. System for uranium superficial density measurement in U3Si2 MTR fuel plates using radiography

    International Nuclear Information System (INIS)

    Hey, Martin A.; Gomez Marlasca, Fernando

    2003-01-01

    The paper describes a method for measuring uranium superficial density in high density uranium silicide (U 3 Si 2 ) MTR fuel plates, through the use of industrial radiography, a set of patterns built for this purpose, a transmission optical densitometer, and a quantitative model of analysis and measurement. Our choice for this particular method responds to its high accuracy, low cost and easy implementation according to the standing quality control systems. (author)

  11. A study of quantitative radiography for moisture content distributions in plant

    Energy Technology Data Exchange (ETDEWEB)

    Kawabata, Y.; Hino, M. [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Institute; Matsushima, U. [Ryukyu Univ., Faculty of Agriculture, Nishihara, Okinawa (Japan); Horie, T. [Kawasaki Heavy Industries, Ltd., Tokyo (Japan)

    2003-01-01

    Vacuum pre-cooling in cut flower or perishable vegetables industry are used for protecting from the deterioration of the perishables during transportation. Some improvements of the pre-cooling way, however, are required for a bruise in plant on the way of handling. Neutron radiography is suitable to detect and observe the bruise in plant, especially, moisture content distributions in leaves, flowers and stalks. Neutron spectrum in irradiation neutron beams is required for obtaining quantitative moisture contents in plant. The neutron spectrum measurements for determination of effective cross-section of water are carried out at CN-3 experimental hole of Kyoto University Reactor (KUR) by time of flight method. Moisture content distributions in leaves of chrysanthemum, before and after the vacuum pre-cooling are measured by cold neutron radiography at the experimental hole. The local decreases of moisture contents caused by a bruise on the surface of the leaves are measured quantitatively by the cold neutron radiography. The quantitative changes of the moisture content in the leaves are able to read out from the cold neutron radiography image. (M. Suetake)

  12. Absorbed dose in the full-mouth periapical radiography, panoramic radiography, and zonography

    International Nuclear Information System (INIS)

    Choi, Soon Chul; Choi, Hang Moon

    1999-01-01

    The objective of this study was to evaluate the possibility of substitution of the zonography for the full-mouth periapical radiography in aspect of radiation protection. Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses at brain, skin above the TMJ, parotid gland, bone marrow in the mandibular body, and thyroid gland during the full-mouth periapical radiography, panoramic radiography, and zonography were measured. From the zonography, the absorbed doses to the brain, the skin over the TMJ, and the parotid gland were relatively high, but the absorbed doses to the bone marrow in the mandibular body and, especially, the thyroid gland were very low. The zonography can be an alternative to the full-mouth periapical radiography in aspect of radiation protection.

  13. Absorbed dose in the full-mouth periapical radiography, panoramic radiography, and zonography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Soon Chul; Choi, Hang Moon [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, College of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    1999-02-15

    The objective of this study was to evaluate the possibility of substitution of the zonography for the full-mouth periapical radiography in aspect of radiation protection. Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses at brain, skin above the TMJ, parotid gland, bone marrow in the mandibular body, and thyroid gland during the full-mouth periapical radiography, panoramic radiography, and zonography were measured. From the zonography, the absorbed doses to the brain, the skin over the TMJ, and the parotid gland were relatively high, but the absorbed doses to the bone marrow in the mandibular body and, especially, the thyroid gland were very low. The zonography can be an alternative to the full-mouth periapical radiography in aspect of radiation protection.

  14. Radiation characteristics of scintillator coupled CMOS APS for radiography conditions

    International Nuclear Information System (INIS)

    Kim, Kwang Hyun; Kim, Soongpyung; Kang, Dong-Won; Kim, Dong-Kie

    2006-01-01

    Under industrial radiography conditions, we analyzed short-term radiation characteristics of scintillator coupled CMOS APS (hereinafter SC CMOS APS). By means of experimentation, the contribution of the transmitted X-ray through the scintillator to the properties of the CMOS APS and the afterimage, generated in the acquired image even at low dose condition, were investigated. To see the transmitted X-ray effects on the CMOS APS, Fein focus TM X-ray machine, two scintillators of Lanex TM Fine and Regular, and two CMOS APS array of RadEye TM were used under the conditions of 50 kV p /1 mAs and 100 kV p /1 mAs. By measuring the transmitted X-ray on signal and Noise Power Spectrum, we analytically examined the generation mechanism of the afterimage, based on dark signal or dark current increase in the sensor, and explained the afterimage in the SC CMOS APS

  15. Control Systems Security Center Comparison Study of Industrial Control System Standards against the Control Systems Protection Framework Cyber-Security Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Robert P. Evans

    2005-09-01

    Cyber security standards, guidelines, and best practices for control systems are critical requirements that have been delineated and formally recognized by industry and government entities. Cyber security standards provide a common language within the industrial control system community, both national and international, to facilitate understanding of security awareness issues but, ultimately, they are intended to strengthen cyber security for control systems. This study and the preliminary findings outlined in this report are an initial attempt by the Control Systems Security Center (CSSC) Standard Awareness Team to better understand how existing and emerging industry standards, guidelines, and best practices address cyber security for industrial control systems. The Standard Awareness Team comprised subject matter experts in control systems and cyber security technologies and standards from several Department of Energy (DOE) National Laboratories, including Argonne National Laboratory, Idaho National Laboratory, Pacific Northwest National Laboratory, and Sandia National Laboratories. This study was conducted in two parts: a standard identification effort and a comparison analysis effort. During the standard identification effort, the Standard Awareness Team conducted a comprehensive open-source survey of existing control systems security standards, regulations, and guidelines in several of the critical infrastructure (CI) sectors, including the telecommunication, water, chemical, energy (electric power, petroleum and oil, natural gas), and transportation--rail sectors and sub-sectors. During the comparison analysis effort, the team compared the requirements contained in selected, identified, industry standards with the cyber security requirements in ''Cyber Security Protection Framework'', Version 0.9 (hereafter referred to as the ''Framework''). For each of the seven sector/sub-sectors listed above, one standard was

  16. Production System Analysis of Brem Processing Unit (Case Study: The Industrial Centers of Brem in Kaliabu and Bancong Village, Madiun District

    Directory of Open Access Journals (Sweden)

    Ardaneswari Dyah Pitaloka Citraresmi

    2014-10-01

    Full Text Available The purpose of this study was to determine the condition, the priorities, and the strategy development policy of the brem Madiun production system as an effort to increase the brem Madiun production system. The samples which are used were the brem industries at industrial centers of brem in Kaliabu and Bancong Village at Madiun District. The main instrument to collect the data was a questionnaire for 21 respondents of business leaders. Data analysis method which is used was Analytical Hierarchy Process (AHP. The results showed that the sequence of factors causing the decline of brem’s production capacity were the final product (0,477, capital (0,244, raw materials (0,123, human resources (0,088, the tools and machinery (0,041, and the method (0,026. Benchmarks for goals to be achieved by the production system were the effectiveness of brem Madiun (0,548, productivity (0,227, efficiency (0,138, and quality (0,087. Strategies that can be done on developing the brem industry in Madiun are provision of venture capital to support the administrations, improvement of licensing services, improvement of joint venture accessibility on infrastructure production, supporting on marketing, improvement of human resources quality (coaching and training, development of product, improvement of business management, and development on network of business partnership respectively. After the several strategies development policy was formulated based on existing condition, then the performance of the brem Madiun production system can be improved. Keywords : Brem, Production System Analysis, Strategy Formulation

  17. Industrial applications of radiations

    International Nuclear Information System (INIS)

    Gallien, C.L.

    1988-01-01

    Radiation processing refers to the use of ionizing radiation to initiate chemical or biological changes in various materials as a substitute for conventional thermal or chemical processes. The method was inroduced in the industrial field 30 years ago and is now being widely used for numerous applications, among which industrial radiography, polymer modification, sterilization or decontamination, and food preservation. Both electron beam accelerators and gamma sources can be used, depending mainly of the amount of radiation and the penetration required. Radiation processing presents an increasing economical importance; in 1986 the market volume of ionized products ranged 3 billion $ [fr

  18. Impact of computers in radiography: the advent of digital radiography, part-2

    International Nuclear Information System (INIS)

    Verma, B.S.; Indrajit, I.K.

    2008-01-01

    Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

  19. Absorbed doses for patients undergoing panoramic radiography, cephalometric radiography and CBCT.

    OpenAIRE

    Wrzesien, Małgorzata; Olszewski, Jerzy

    2017-01-01

    Objectives: Contemporary dental radiology offers a wide spectrum of imaging methods but it also contributes to an increase in the participation of dental radiological diagnosis in the patient’s exposure to ionizing radiation. The aim of this study is to determine the absorbed doses of the brain, spinal column, thyroid and eye lens for patients during panoramic radiography, cephalometric radiography and cone beam computed tomography (CBCT). Material and Methods: The thermoluminescent dosimetry...

  20. Evaluation of ultrasound training in the problem based learning radiography curriculum at Makerere University, Uganda

    International Nuclear Information System (INIS)

    Elsie, Kiguli-Malwadde; Gonzaga, Mubuuke A.; Francis, Businge; Rebecca, Nakatudde; Stephen, Bule

    2010-01-01

    Introduction: The College of Health Sciences (CHS), Makerere University has been training health professionals since 1924. Six years ago, there was a curriculum change to Problem Based Learning/Community based Education and Service (PBL/COBES). A SPICES model (Student centered, problem based, integrated, community based, electives, systematic) was adopted and defined to suit the CHS environment. The radiography program is 3 years in length which involves Ultrasound as an important part of the training. It was a challenge to adopt the new PBL method of learning after having a lecture-based pedagogical method for over 80 years. Objective: To implement the training of ultrasound in the PBL radiography curriculum as well as evaluate the opinions of the staff and students about Ultrasound training in the new curriculum. Methodology: A participatory approach was used. Workshops were conducted and objectives for ultrasound courses refined. Scenarios were written for use in the PBL sessions. A retrospective review of student performance in the ultrasound courses was carried out. A cross-sectional survey involving teachers and current radiography students was also carried out to evaluate learning of ultrasound using the PBL approach. Results: Students have consistently excelled in ultrasound courses using the PBL approach of learning. Both teachers and students rated the teaching of ultrasound to radiography students as being highly important and supported the new approach to training. Conclusion: Ultrasound training using PBL has been successfully implemented. However, this is still an ongoing process and will require the total commitment of both students and teachers.

  1. Evaluation of ultrasound training in the problem based learning radiography curriculum at Makerere University, Uganda

    Energy Technology Data Exchange (ETDEWEB)

    Elsie, Kiguli-Malwadde [Makerere University, College of Health Sciences, Radiology Department, Kampala (Uganda); Gonzaga, Mubuuke A., E-mail: gmubuuke@gmail.co [Makerere University, College of Health Sciences, Radiology Department, Kampala (Uganda); Francis, Businge; Rebecca, Nakatudde; Stephen, Bule [Makerere University, College of Health Sciences, Radiology Department, Kampala (Uganda)

    2010-11-15

    Introduction: The College of Health Sciences (CHS), Makerere University has been training health professionals since 1924. Six years ago, there was a curriculum change to Problem Based Learning/Community based Education and Service (PBL/COBES). A SPICES model (Student centered, problem based, integrated, community based, electives, systematic) was adopted and defined to suit the CHS environment. The radiography program is 3 years in length which involves Ultrasound as an important part of the training. It was a challenge to adopt the new PBL method of learning after having a lecture-based pedagogical method for over 80 years. Objective: To implement the training of ultrasound in the PBL radiography curriculum as well as evaluate the opinions of the staff and students about Ultrasound training in the new curriculum. Methodology: A participatory approach was used. Workshops were conducted and objectives for ultrasound courses refined. Scenarios were written for use in the PBL sessions. A retrospective review of student performance in the ultrasound courses was carried out. A cross-sectional survey involving teachers and current radiography students was also carried out to evaluate learning of ultrasound using the PBL approach. Results: Students have consistently excelled in ultrasound courses using the PBL approach of learning. Both teachers and students rated the teaching of ultrasound to radiography students as being highly important and supported the new approach to training. Conclusion: Ultrasound training using PBL has been successfully implemented. However, this is still an ongoing process and will require the total commitment of both students and teachers.

  2. REVIEW ARTICLE REVI REVI Computed radiography exposure ...

    African Journals Online (AJOL)

    Background. Studies indicate that computed radiography (CR) can lead to increased radiation dose to patients. It is therefore important to relate the exposure indicators provided by CR manufacturers to the radiation dose delivered so as to assess the radiation dose delivered to patients directly from the exposure indicators.

  3. Radiography Student Participation in Professional Organizations.

    Science.gov (United States)

    Michael, Kimberly; Tran, Xuan; Keller, Shelby; Sayles, Harlan; Custer, Tanya

    2017-09-01

    To gather data on educational program requirements for student membership in a state or national professional society, organization, or association. A 10-question online survey about student involvement in professional societies was emailed to 616 directors of Joint Review Committee on Education in Radiologic Technology (JRCERT)-accredited radiography programs. A total of 219 responses were received, for a 36% response rate. Of these, 89 respondents (41%) answered that their programs require students to join a professional organization. The society respondents most often required (70%) was a state radiography society. Sixty respondents (68%) answered that students join a society at the beginning of the radiography program (from matriculation to 3 months in). Of programs requiring student membership in professional societies, 42 (49%) reported that their students attend the state or national society annual conference; however, participation in activities at the conferences and in the society throughout the year is lower than conference attendance. Some directors stated that although their programs' policies do not allow membership mandates, they encourage students to become members, primarily so that they can access webinars and other educational materials or information related to the profession. Survey data showed that most JRCERT-accredited radiography programs support but do not require student membership in professional organizations. The data reveal that more programs have added those requirements in recent years. Increased student participation could be realized if programs mandated membership and supported it financially. ©2017 American Society of Radiologic Technologists.

  4. Feline dental radiography and radiology: A primer.

    Science.gov (United States)

    Niemiec, Brook A

    2014-11-01

    Information crucial to the diagnosis and treatment of feline oral diseases can be ascertained using dental radiography and the inclusion of this technology has been shown to be the best way to improve a dental practice. Becoming familar with the techniques required for dental radiology and radiography can, therefore, be greatly beneficial. Novices to dental radiography may need some time to adjust and become comfortable with the techniques. If using dental radiographic film, the generally recommended 'E' or 'F' speeds may be frustrating at first, due to their more specific exposure and image development requirements. Although interpreting dental radiographs is similar to interpreting a standard bony radiograph, there are pathologic states that are unique to the oral cavity and several normal anatomic structures that may mimic pathologic changes. Determining which teeth have been imaged also requires a firm knowledge of oral anatomy as well as the architecture of dental films/digital systems. This article draws on a range of dental radiography and radiology resources, and the benefit of the author's own experience, to review the basics of taking and interpreting intraoral dental radiographs. A simplified method for positioning the tubehead is explained and classic examples of some common oral pathologies are provided. © ISFM and AAFP 2014.

  5. Optimal radiography of the horsetoe in practice

    International Nuclear Information System (INIS)

    Tellhelm, B.; Fritsch, R.; Reckels, F.-J.

    1988-01-01

    Requirements for optimal radiography of the horsetoe are described. Examples are given for getting X-rays of high quality under practice conditions, by using special intensifying screens and all the possibilities of radiological technique to guarantee a short exposure time

  6. Sizes of films for medical radiography - 1972

    Energy Technology Data Exchange (ETDEWEB)

    1976-01-01

    This standard covers sizes of film for medical radiography, excluding periapical and occlusal X-ray film (see BS--2585) in both sheet and roll form. The dimensions of cores for film used in roll form, squareness, quantity packaging and marking are also specified. This standard agrees with ISO/R 425.

  7. Comprehensive Optimization Process of Paranasal Sinus Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Saarakkala, S. (Dept. of Clinical Radiology, Kuopio Univ. Hospital, Kuopio (Finland)); Nironen, K.; Hermunen, H.; Aarnio, J.; Heikkinen, J.O. (Dept. of Radiology, Etel-Savo Hospital District, Mikkeli Central Hospital, Mikkeli (Finland))

    2009-04-15

    Background: The optimization of radiological examinations is important in order to reduce unnecessary patient radiation exposure. Purpose: To perform a comprehensive optimization process for paranasal sinus radiography at Mikkeli Central Hospital (Finland). Material and Methods: Patients with suspicion of acute sinusitis were imaged with a Kodak computed radiography (CR) system (n=20) and with a Philips digital radiography (DR) system (n=30) using focus-detector distances (FDDs) of 110 cm, 150 cm, or 200 cm. Patients' radiation exposure was determined in terms of entrance surface dose and dose-area product. Furthermore, an anatomical phantom was used for the estimation of point doses inside the head. Clinical image quality was evaluated by an experienced radiologist, and physical image quality was evaluated from the digital radiography phantom. Results: Patient doses were significantly lower and image quality better with the DR system compared to the CR system. The differences in patient dose and physical image quality were small with varying FDD. Clinical image quality of the DR system was lowest with FDD of 200 cm. Further, imaging with FDD of 150 cm was technically easier for the technologist to perform than with FDD of 110 cm. Conclusion: After optimization, it was recommended that the DR system with FDD of 150 cm should always be used at Mikkeli Central Hospital. We recommend this kind of comprehensive approach in all optimization processes of radiological examinations.

  8. Small-angle scattering, topography and radiography

    International Nuclear Information System (INIS)

    Schelten, J.

    1978-01-01

    A table is given showing scattering and imaging methods for X-rays and neutrons, followed, by a discussion of such topics as 1. Radiography 2. Topography 3. Small-angle scattering 3.1. The differential cross section 3.2. Comparison of X-ray and neutron small-angle scattering 3.3. Examples of small-angle scattering. (orig.) [de

  9. Technique and interpretation in tree seed radiography

    Science.gov (United States)

    Howard B. Kriebel

    1966-01-01

    The study of internal seed structure by radiography requires techniques which will give good definition. To establish the best procedures, we conducted a series of experiments in which we manipulated the principal controllable variables affecting the quality of X-radiographs: namely, focus-to-film distance, film speed (grain), exposure time, kilovoltage, and...

  10. Computed Radiography Exposure Indices in Mammography | Koen ...

    African Journals Online (AJOL)

    Background. Studies indicate that computed radiography (CR) can lead to increased radiation dose to patients. It is therefore important to relate the exposure indicators provided by CR manufacturers to the radiation dose delivered so as to assess the radiation dose delivered to patients directly from the exposure indicators.

  11. Establishing rigour in qualitative radiography research

    International Nuclear Information System (INIS)

    Murphy, F.J.; Yielder, J.

    2010-01-01

    The vast majority of radiography research is subject to critique and evaluation from peers in order to justify the method and the outcome of the study. Within the quantitative domain, which the majority of medical imaging publications tend to fall into, there are prescribed methods for establishing scientific rigour and quality in order to critique a study. However, researchers within the qualitative paradigm, which is a developing area of radiography research, are often unclear about the most appropriate methods to measure the rigour (standards and quality) of a research study. This article considers the issues related to rigour, reliability and validity within qualitative research. The concepts of reliability and validity are briefly discussed within traditional positivism and then the attempts to use these terms as a measure of quality within qualitative research are explored. Alternative methods for research rigour in interpretive research (meanings and emotions) are suggested in order to compliment the existing radiography framework that exists for qualitative studies. The authors propose the use of an established model that is adapted to reflect the iterative process of qualitative research. Although a mechanistic approach to establishing rigour is rejected by many qualitative researchers, it is argued that a guide for novice researchers within a developing research base such as radiography is appropriate in order to establish the credibility and trustworthiness of a qualitative study.

  12. Establishing rigour in qualitative radiography research

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, F.J. [School of Healthcare Professions, University of Salford, Salford M6 6PU (United Kingdom)], E-mail: f.j.murphy@salford.ac.uk; Yielder, J. [Medical Imaging, School of Health Sciences, Unitec, Auckland (New Zealand)

    2010-02-15

    The vast majority of radiography research is subject to critique and evaluation from peers in order to justify the method and the outcome of the study. Within the quantitative domain, which the majority of medical imaging publications tend to fall into, there are prescribed methods for establishing scientific rigour and quality in order to critique a study. However, researchers within the qualitative paradigm, which is a developing area of radiography research, are often unclear about the most appropriate methods to measure the rigour (standards and quality) of a research study. This article considers the issues related to rigour, reliability and validity within qualitative research. The concepts of reliability and validity are briefly discussed within traditional positivism and then the attempts to use these terms as a measure of quality within qualitative research are explored. Alternative methods for research rigour in interpretive research (meanings and emotions) are suggested in order to compliment the existing radiography framework that exists for qualitative studies. The authors propose the use of an established model that is adapted to reflect the iterative process of qualitative research. Although a mechanistic approach to establishing rigour is rejected by many qualitative researchers, it is argued that a guide for novice researchers within a developing research base such as radiography is appropriate in order to establish the credibility and trustworthiness of a qualitative study.

  13. Comparison of the efficacy of conventional radiography, digital radiography, and ultrasound in diagnosing periapical lesions.

    Science.gov (United States)

    Raghav, Namita; Reddy, Sujatha S; Giridhar, A G; Murthy, Srinivas; Yashodha Devi, B K; Santana, N; Rakesh, N; Kaushik, Atul

    2010-09-01

    The aim of this study was to evaluate the efficacy of conventional radiography, digital radiography and ultrasound imaging in diagnosing periapical lesions. Twenty-one patients aged between 15 and 45 years with well defined periapical radiolucency associated with anterior maxillary or mandibular teeth requiring endodontic surgery or extraction were selected and consented to the study. Preoperative intraoral periapical radiographs and digital images using charge-coupled device obtained by paralleling technique were assessed by 3 specialist observers who gave their diagnosis of the periapical lesions. Then ultrasound examination was performed and the images were assessed for size, contents, and vascular supply by 3 ultrasonographers. It was followed by curettage of periapical tissues to enable histopathologic investigation, which is the gold standard in diagnosis. The data were statistically analyzed using SPSS, analysis of variance, and kappa statistics. The percentage accuracy of diagnosing periapical lesions using conventional radiography was 47.6%, digital radiography 55.6%, and ultrasound 95.2%. Ultrasound had the highest sensitivity and specificity: 0.95 and 1.00, respectively. Conventional and digital radiography enable diagnosis of periapical diseases, but not their nature, whereas ultrasound provides accurate information on the pathologic nature of the lesions, which is of importance in predicting the treatment outcome. Therefore ultrasound can be used as an adjunct to conventional or digital radiography in diagnosing periapical lesions. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  14. Comparison of Waters' radiography, panoramic radiography, and computed tomography in the diagnosis of antral mucosal thickening

    International Nuclear Information System (INIS)

    Hyun, Young Min; Lee, Sam Sun; Choi, Soon Chul

    1998-01-01

    With the CT findings as gold standard, the sensitivity, the specificity, and the diagnostic accuracy of Waters' radiography and Waters' radiography with panoramic radiography were compared in the diagnosis of antral mucosal thickening of 16 patients. Three oral radiologists and three non-oral radiologists interpreted the Waters' radiographs and after 4 weeks, interpreted the Waters' radiographs and panoramic radiographs simultaneously. The interpretation was the existence or the non-existence of the mucosal thickening on the medial, the posterolateral, the floor, and the roof of maxillary sinus. The obtained results were as followed ; 1. In oral radiologist group, the sensitivity, specificity and diagnostic accuracy of Waters' film were 0.7250, 0.8489 and 0.7578 respectively. 2. The sensitivity and the diagnostic accuracy in oral radiologist group were higher than those of non-oral radiologist group (P 0.05). 3. There was no significant difference of the diagnostic abilities except the specificity in oral radiologist group between Waters' radiography and Waters' radiography with panoramic radiography (P>0.05). 4. The sensitivity and the diagnostic accuracy were the highest in the case of medial wall interpretation, the specificity was the highest in the posterolateral wall. 5. In the posterolateral wall and the floor, the sensitivity and the diagnostic accuracy of oral radiologist group were higher than those of non-oral radiologist group (P<0.05)

  15. Radiography - A new field among health sciences in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Pakarinen, Ritva [Licentiate of Health Sciences, Department of Nursing Science and Health Administration, University of Oulu, Lamsantie 14 A1, 90230 Oulu (Finland)]. E-mail: ritva.pakarinen@oulu.fi; Jussila, Aino-Liisa [Doctor of Health Sciences, Department of Social and Health Care, Oulu Polytechnic, Oulu (Finland)

    2007-08-15

    In order to secure high quality X-ray services and efficient operation of clinical radiography, a study programme in radiography science was implemented at the University of Oulu in 1999. The need for a specific field of science has emerged as a result of social changes, such as the aging population, and the fast development of technology that has caused significant changes in the radiological working environment and clinical radiography. A need for a new, research-based informational foundation of clinical radiography is the basis for the programme. As service producers, radiographers need vast knowledge as well as specific expertise. The research object of radiography science is clinical radiography. If it was studied from the viewpoint of other sciences, the key professional skills of a radiographer would remain unexplored. Implementing an own field of science has enabled the development of radiography from its own bases. Basic research in the field is represented, for example, by the concept analysis of radiography in health sciences. Radiography science should produce research results for both clinical radiography and the instruction of radiography. So far, research results have dealt with the professional decision-making of a radiographer, the influences of computer technology on a radiographer's work and measuring the radiation exposure of a population.

  16. Radiography - A new field among health sciences in Finland

    International Nuclear Information System (INIS)

    Pakarinen, Ritva; Jussila, Aino-Liisa

    2007-01-01

    In order to secure high quality X-ray services and efficient operation of clinical radiography, a study programme in radiography science was implemented at the University of Oulu in 1999. The need for a specific field of science has emerged as a result of social changes, such as the aging population, and the fast development of technology that has caused significant changes in the radiological working environment and clinical radiography. A need for a new, research-based informational foundation of clinical radiography is the basis for the programme. As service producers, radiographers need vast knowledge as well as specific expertise. The research object of radiography science is clinical radiography. If it was studied from the viewpoint of other sciences, the key professional skills of a radiographer would remain unexplored. Implementing an own field of science has enabled the development of radiography from its own bases. Basic research in the field is represented, for example, by the concept analysis of radiography in health sciences. Radiography science should produce research results for both clinical radiography and the instruction of radiography. So far, research results have dealt with the professional decision-making of a radiographer, the influences of computer technology on a radiographer's work and measuring the radiation exposure of a population

  17. The advantages of digital radiography in department of radiology

    International Nuclear Information System (INIS)

    Mao Lijuan; Luo Xiaomei; Wu Tengfang

    2009-01-01

    Objective: To investigate the advantages of digital radiography in department of radiology by comparing digital radiography with common radiography. Methods: Test card was used for testing the spatial resolution of DR and common radiography. 1000 films of chest by DR and 1000 films of chest by common radiography were compared in image quality, dose of radiation, the rate of waste film, and the advantages of DR was analyzed. Results: Compared to common radiography, DR had a high sensitivity, high DQE (quantum detection efficiency), high spatial resolution and density resolution. The speed of acquisition and X-ray conversion efficiency were fast. The function of post-processing was strong and the rate of disease detection was high. Conclusion: DR is better than common radiography in all respects, it will be widely applied. (authors)

  18. Two-phase fluid flow measurements in small diameter channels using real-time neutron radiography

    International Nuclear Information System (INIS)

    Carlisle, B.S.; Johns, R.C.; Hassan, Y.A.

    2004-01-01

    A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)

  19. Optimization of the Army’s Fast Neutron Moderator for Radiography

    Science.gov (United States)

    2013-02-26

    Development, and Engineering Center (ARDEC). From the early 1970s through the 1980s, neutron imaging was done using Californium - 252 (Cf- 252 ), and showed...Measurement c centi-, 1E-2 Cf- 252 Californium isotope 252 COTS Commercials off the shelf D-D Deuterium – Deuterium DoD Department of...Physicist and Level III Radiographer (retired); Mendham, NJ - For technical discussions on neutron radiography using Cf- 252 . Jeanne Schwartz; ARDEC

  20. A third generation mobile high energy radiography system

    International Nuclear Information System (INIS)

    Fry, D.A.; Valdez, J.E.; Johnson, C.S.; Kimerly, H.J.; Vananne, J.R.

    1997-01-01

    A third generation mobile high energy radiographic capability has been completed and put into service by the Los Alamos National Laboratory. The system includes a 6 MeV linac x-ray generator, Co-60 gamma source, all-terrain transportation, on-board power, real-time radiography (RTR), a control center, and a complete darkroom capability. The latest version includes upgraded and enhanced portability, flexibility, all-terrain operation, all-weather operation, and ease of use features learned from experience with the first and second generation systems. All systems were required to have the following characteristics; all-terrain, all-weather operation, self-powered, USAF airlift compatible, reliable, simple to setup, easy to operate, and all components two-person portable. The systems have met these characteristics to differing degrees, as is discussed in the following section, with the latest system being the most capable

  1. High Brightness Neutron Source for Radiography. Final report

    International Nuclear Information System (INIS)

    Cremer, J.T.; Piestrup, Melvin A.; Gary, Charles K.; Harris, Jack L.; Williams, David J.; Jones, Glenn E.; Vainionpaa, J.H.; Fuller, Michael J.; Rothbart, George H.; Kwan, J.W.; Ludewigt, B.A.; Gough, R.A.; Reijonen, Jani; Leung, Ka-Ngo

    2008-01-01

    of yield of two orders of magnitude. The first fast neutron radiographic images were obtained using neutron cameras and a new fast neutron generator. These early images demonstrated the feasibility of using fast neutrons for imaging and penetrating thick objects of high density and imaging. Fast neutrons can be used to image low atomic number materials (e.g. plastics, explosives, lubricants and ceramics) that are shielded by high density materials (e.g. lead, tungsten and uranium). Fast neutron radiography could be used as a means to screen weapons for flaws and chemical stability. X-ray radiography can not easily do this. Fast neutron imaging is technically difficult and, consequently, a completely undeveloped market. Two of the generators were designed to have small source size and high brightness, ideal for fast-neutron imaging. With these generators we successfully used two fast neutron cameras: one developed by us, and another developed by a collaborator, Commonwealth Scientific and Industrial Research Organization, CSIRO. We have successfully used these cameras to obtain low resolution images of various objects such as pipe fittings filled with water and other mechanical objects. Higher resolution and contrast images are expected by decreasing the source size and increasing generator yield.

  2. 10 CFR 34.41 - Conducting industrial radiographic operations.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Conducting industrial radiographic operations. 34.41 Section 34.41 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY REQUIREMENTS FOR INDUSTRIAL RADIOGRAPHIC OPERATIONS Radiation Safety Requirements § 34.41...

  3. National Survey of Radiation Doses of Pediatric Chest Radiography in Korea: Analysis of the Factors Affecting Radiation Doses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Hyun; Do, Kyung Hyun; Goo, Hyun Woo; Yang, Dong Hyun; Oh, Sang Young [Dept. of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Kim, Hyeong Ju; Lee, Kwang Yong; Lee, Jung Eun [National Institute of Food and Drug Safety Evaluation, Radiation Safety Division, Cheongwon (Korea, Republic of)

    2012-09-15

    To investigate radiation doses in pediatric chest radiography in a national survey and to analyze the factors that affect radiation doses. The study was based on the results of 149 chest radiography machines in 135 hospitals nationwide. For each machine, a chest radiograph was obtained by using a phantom representing a 5-year-old child (ATOM dosimetry phantom, model 705-D, CIRS, Norfolk, VA, USA) with each hospital's own protocol. Five glass dosimeters (M-GD352M, Asahi Techno Glass Corporation, Shizuoka, Japan) were horizontally installed at the center of the phantom to measure the dose. Other factors including machine's radiography system, presence of dedicated pediatric radiography machine, presence of an attending pediatric radiologist, and the use of automatic exposure control (AEC) were also evaluated. The average protocol for pediatric chest radiography examination in Korea was 94.9 peak kilovoltage and 4.30 milliampere second. The mean entrance surface dose (ESD) during a single examination was 140.4 microgray ({mu}Gy). The third quartile, median, minimum and maximum value of ESD were 160.8 {mu}Gy, 93.4 {mu}Gy, 18.8 {mu}Gy, and 2334.6 {mu}Gy, respectively. There was no significant dose difference between digital and non-digital radiography systems. The use of AEC significantly reduced radiation doses of pediatric chest radiographs (p < 0.001). Our nationwide survey shows that the third quartile, median, and mean ESD for pediatric chest radiograph is 160.8 {mu}Gy, 93.4 {mu}Gy, and 140.4 {mu}Gy, respectively. No significant dose difference is noticed between digital and non-digital radiography systems, and the use of AEC helps significantly reduce radiation doses.

  4. From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation

    International Nuclear Information System (INIS)

    Cuzin, M.

    1993-01-01

    In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors)

  5. Dental radiography in New Zealand: digital versus film.

    Science.gov (United States)

    Ting, N A; Broadbent, J M; Duncan, W J

    2013-09-01

    Digital x-ray systems offer advantages over conventional film systems, yet many dentists have not adopted digital technology. To assess New Zealand dental practitioners' use of--and preferences for--dental radiography systems. Cross-sectional survey. General and specialist dental practice. Postal questionnaire survey of a sample of 770 dentists (520 randomly selected general dental practitioners and all 250 specialists) listed in the 2012 NZ Dental Council Register. Type of radiography systems used by dentists. Dentists' experiences and opinions of conventional film and digital radiography. The participation rate was 55.2%. Digital radiography systems were used by 58.0% of participating dentists, most commonly among those aged 31-40 years. Users of digital radiography tended to report greater satisfaction with their radiography systems than users conventional films. Two-thirds of film users were interested in switching to digital radiography in the near future. Reasons given by conventional film users for not using digital radiography included cost, difficulty in integrating with other software systems, concern about potential technical errors, and the size and nature of the intra-oral sensors. Many dental practitioners have still not adopted digital radiography, yet its users are more satisfied with their radiography systems than are conventional film users. The latter may find changing to a digital system to be satisfying and rewarding.

  6. Efficacy of panoramic radiography as a screening procedure in dental examination compared with clinical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    An, Seo Young; An, Chang Hyeon; Choi, Karp Shik [Kyungpook National Univ. School of Dentistry, Daegu (Korea, Republic of)

    2007-06-15

    To evaluate the efficacy of panoramic radiography by comparing the results of clinical examination with radiographic findings. We studied 190 patients (20 men and 170 women; mean age, 40 years; range, 22 to 68 years) who visited the health promotion center of Korea Medical Science Institute and were examined both clinically and by panoramic radiography. We compared results from both examinations. Treatment options by clinical examination were described as 'no treatment indicated', 'treatment of dental caries', 'removal of calculus', 'treatment of periodontal disease'. 'prothodonic treatment' and 'extraction of the third molar'. Findings taken from the panoramic radiography were: dental caries, peroapical lesion, alveolar bone loss, calculus deposition, retained root, impaction of the third molar, disease of maxillary sinus, bony change of mandibular condyle, etc. The prevalence of panoramic findings were: 37.9% of dental caries, 17.4% of periapical lesions, 44.7% of alveolar bone losses, 62.6% of calculi deposition. 7.9% of retained roots, 26.8% of third molar impactions, 6.3% of disease of maxillary sinus, 2.1% of bony changes of mandibular condlye and 35.8% of miscellaneous lesions. Abnormal conditions revealed by panoramic radiography which had not been discovered on clinical examination were: 24.2% of the patients had dental caries, 17.4% had periapical lesions, 7.4% had calculi deposition, 5.3% had retained roots, 15.3% had third molar impactions. The opposite cases were: 5.2% had dental caries, 12.6% had calculi deposition, and 9.5% had third molar impactions. The use of panoramic radiography as a supplement to the clinical examination might be a valuable screening technique.

  7. Efficacy of panoramic radiography as a screening procedure in dental examination compared with clinical evaluation

    International Nuclear Information System (INIS)

    An, Seo Young; An, Chang Hyeon; Choi, Karp Shik

    2007-01-01

    To evaluate the efficacy of panoramic radiography by comparing the results of clinical examination with radiographic findings. We studied 190 patients (20 men and 170 women; mean age, 40 years; range, 22 to 68 years) who visited the health promotion center of Korea Medical Science Institute and were examined both clinically and by panoramic radiography. We compared results from both examinations. Treatment options by clinical examination were described as 'no treatment indicated', 'treatment of dental caries', 'removal of calculus', 'treatment of periodontal disease'. 'prothodonic treatment' and 'extraction of the third molar'. Findings taken from the panoramic radiography were: dental caries, peroapical lesion, alveolar bone loss, calculus deposition, retained root, impaction of the third molar, disease of maxillary sinus, bony change of mandibular condyle, etc. The prevalence of panoramic findings were: 37.9% of dental caries, 17.4% of periapical lesions, 44.7% of alveolar bone losses, 62.6% of calculi deposition. 7.9% of retained roots, 26.8% of third molar impactions, 6.3% of disease of maxillary sinus, 2.1% of bony changes of mandibular condlye and 35.8% of miscellaneous lesions. Abnormal conditions revealed by panoramic radiography which had not been discovered on clinical examination were: 24.2% of the patients had dental caries, 17.4% had periapical lesions, 7.4% had calculi deposition, 5.3% had retained roots, 15.3% had third molar impactions. The opposite cases were: 5.2% had dental caries, 12.6% had calculi deposition, and 9.5% had third molar impactions. The use of panoramic radiography as a supplement to the clinical examination might be a valuable screening technique

  8. Interconnection of industrial centers with the electric network of the public service; Interconexion de centros industriales con la red electrica del servicio publico

    Energy Technology Data Exchange (ETDEWEB)

    Rosales Sedano, Inocente; Lopez Velazquez, Juan Jose; Garcia Paredes, Job; Robles Pimentel, Edgar [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico); Garcia Alvarez, David; Guzman Camacho, Benigno [Petroleos Mexicanos (Mexico)

    2000-07-01

    The large industrial centers that have continuous production processes and consume high amounts of electrical energy, generally have their own power generation. The petrochemical complexes, the paper and steel factories and the sugar mills are examples of this type of centers. On the other hand, the new regulation for the generation of electrical energy that allows to the electrical energy interchange between private companies and the public network, has originated the necessity of connecting systems that formerly operated isolated. Since the original design of the isolated electrical systems was to operate in an independent form, making the interconnection can generate technical problems that must be analyzed and solved. In this paper, some experiences related with the behavior of electrical equipment when connected to operate with the public network, are presented. [Spanish] Los grandes centros industriales que tienen procesos de produccion continua y consumen altas cantidades de energia electrica, generalmente cuentan con generacion propia. Los complejos petroquimicos, las fabricas de papel y acero y los ingenios azucareros son ejemplos de este tipo de centros. Por otro lado, la nueva reglamentacion de generacion de energia electrica que permite el intercambio de energia electrica entre las companias privadas y la red publica, ha originado la necesidad de conectar sistemas que antes operaban aislados. Debido a que el diseno original de los sistemas electricos aislados fue trabajar en forma independiente, el realizar la interconexion puede generar problemas tecnicos que tienen que analizarse y resolverse. En este articulo, se presentan algunas experiencias relacionadas con el comportamiento del equipo electrico al operar conectado con la red publica.

  9. Radiation exposures of workers resulting from the transport of gamma radiography sources in Germany

    International Nuclear Information System (INIS)

    Sentuc, F.N.; Schwarz, G.

    2006-01-01

    Gamma radiation sources are widely used for industrial purposes e.g. for non-destructive material testing. Many of these sources are permanently installed at a facility within instruments e.g. for level or thickness gauging. Other radioactive sources are implemented in portable devices for industrial gamma radiography which have to be carried to the various remote usage sites. In Germany, approximately 20 000 - 25 000 shipments of gamma radiography sources are proceeding annually on public transport routes. Since routine radiation monitoring programmes do not permit task-specific determination of occupational doses e.g. doses incurred during the movement phase and handling related doses, work has been carried out with the objective to determine the radiation exposures of the personnel attributable to transportation. For this purpose, a survey was launched in 2005 collecting data about e.g. the number and conditions of transports, the activity and type of transported radiation sources and the radiation level within the driver's cab to allow a dose assessment to be made for transport workers. The results of this survey covering the most important companies for gamma radiography services in Germany are presented in this paper. (authors)

  10. Discussion on alternative systems for film radiography

    International Nuclear Information System (INIS)

    Vaessen, B.; Perdieus, P.; Willems, P.

    1997-01-01

    Film radiography is a well-established NDT technique and an accepted method for quality assurance. Recently, so-called new developments have been introduced to the market as alternatives for film radiography. Examples are fluorescent screen/film systems, cost containment films, wide-latitude films and storage phosphor plate systems. The authors have evaluated these systems and their applicability for NDT, taking into account factors such as sensitivity (image quality), speed, handling, portability, reliability. In this paper, the value and applicability for the NDT market of two of these methods, namely fluorescent screen systems and storage phosphor plates, are discussed, in comparison with conventional film techniques. Both technologies have been developed and are available within Agfa-Gevaert, therefore we can overview all aspects for the Agfa strategic NDT market and discuss Agfa's strategy regarding these technologies; the conclusion is that all that is new is not necessarily beautiful. (Author)

  11. Current and future neutron radiography standards

    International Nuclear Information System (INIS)

    Brenizer, J.S.

    1999-01-01

    Only two organizations are actively producing standards which are used in neutron radiology (NR): the American Society of Testing and Materials (ASTM) and the International Organization for Standardization (ISO). Six ASTM standards exist that address the neutron radiography method. Two of the ASTM standards have been extensively used world-wide. ISO has a working group which is developing three standards that also address the neutron radiography method. Two of these are currently making their way through the ISO approval system. No ASTM or ISO standards exist for the neutron radioscopic method. Future ASTM standards will address the neutron radioscopic method and neutron radiologic system characterization. It is expected that similar efforts will be undertaken in ISO. Given the relatively small community providing neutron radiologic services, international cooperation and the need for ISO standards will most likely continue to grow.(author)

  12. Digital radiography in intensive neonatal care

    International Nuclear Information System (INIS)

    Merlo, L.; Bighi, S.; Cervi, P.N.; Lupi, L.; Vita, G.

    1991-01-01

    The authors report their experience with the routinary use of a computerized digital radiography system in Intensive Neonatal Care department. The conventional screen-film system is replaced by photostimulable imaging plates, which are scanned during processing by a laser providing the digital image. The latter is subsequently processable on high-resolution monitors. Over a 6-month period 86 examinations were performed with this method in Intensive Neonatal Care; good technical results were obtained. The use of digital radiography in intensive neonatal care is extremely promising for it allows high-quality images to be obtained, and radiation dose and number of acquisitions to be reduced. Finally, work stations allow both selective visualization of different body structures and their magnification

  13. Deflection evaluation using time-resolved radiography

    International Nuclear Information System (INIS)

    Fry, D.A.; Lucero, J.P.

    1990-01-01

    Time-resolved radiography is the creation of an x-ray image for which both the start-exposure and stop-exposure times are known with respect to the event under study. The combination of image and timing are used to derive information about the event. The authors have applied time-resolved radiography to evaluate motions of explosive-driven events. In the particular application discussed in this paper, the author's intent is to measure maximum deflections of the components involved. Exposures are made during the time just before to just after the event of interest occurs. A smear or blur of motion out to its furthest extent is recorded on the image. Comparison of the dynamic images with static images allows deflection measurements to be made

  14. Retrospective analysis of computed radiography exposure reporting.

    Science.gov (United States)

    David, George; Redden, Amanda E

    2011-01-01

    The increasing public spotlight on medical imaging overuse and radiation overexposure has led to a greater demand for radiation dose monitoring. Computed radiography (CR) exposure reporting databases allow radiographers to monitor dose creep, which can help decrease overall patient radiation exposure from medical examinations. Import exposure data from CR readers into a database that allows administrators to monitor and analyze dose data for quality assurance. A CR exposure reporting database and statistics website was created to analyze CR reader dose data and track dose creep. Radiography departments can effectively monitor dose creep using a CR exposure reporting database to retrieve and analyze dose data, as well as identify dose trends, workloads, radiographer performance, and need for further training on proper technique. This knowledge can help decrease overall patient radiation exposure from medical examinations. ©2011 by the American Society of Radiologic Technologists.

  15. A system for fast neutron radiography

    International Nuclear Information System (INIS)

    Klann, R.T.

    1996-01-01

    A system has been designed and a neutron generator installed to perform fast neutron radiography. With this sytem, objects as small as a coin or as large as a waste drum can be radiographed. The neutron source is an MF Physics A-711 neutron generator which produces 3x10 10 neutrons/second with an average energy of 14.5 MeV. The radiography system uses x-ray scintillation screens and film in commercially available cassettes. The cassettes have been modified to include a thin sheet of plastic to convert neutrons to protons through elastic scattering from hydrogen and other low Z materials in the plastic. For film densities from 1.8 to 3.0, exposures range from 1.9x10 7 to 3.8x10 8 n/cm 2 depending on the type of screen and film

  16. Portable digital electronic radiography system with a solid-state area-imaging detector

    CERN Document Server

    Sawicka, B D; Sonnenburg, K

    1999-01-01

    A digital system for radiographic inspection was constructed in a portable version suitable for field use. The system uses typical film radiography sources, including sup 6 sup 0 Co, sup 1 sup 9 sup 2 1r and X-ray generators. Radiographic images are formed using an area-imaging scintillating detector coupled to a charge-coupled device camera and a portable industrial computer. Compared to film radiography, this technology offers imaging without wet-film processing, shorter exposure times, larger dynamic range, and digital imaging that permits compact archiving, easy data access and mathematical image processing to improve sensitivity. System performance is illustrated for typical applications, i.e., for radiographing valves and pipes. Using ' sup 1 sup 9 sup 2 Ir, the system works well on smaller water-filled valves and pipes; larger valves have to be drained. Work is under way to address this problem.

  17. Improvements in or relating to radiography

    International Nuclear Information System (INIS)

    Marsh, R.G.; Fleming, I.A.

    1980-01-01

    Tomographic apparatus for use in biomedical radiography is described in detail. The radiation source and detectors are capable of rotating around the axis of the body under investigation to measure the absorption coefficients of a particular slice. Additionally, the detectors and source are capable of lateral motion across the body slice. Detailed suggestions of the number and optimum angular size of the detectors are given as well as the various angular steps of rotation of the source and detectors. (UK)

  18. Hybrid pixel detector development for medical radiography

    International Nuclear Information System (INIS)

    Midgley, S.; Berry, A.; Benci, N.; Morton, S.; Phillips, D.; Smith, P.; Troja, S.; Lewis, R.

    2007-01-01

    A 7-year project has been initiated to develop hybrid pixel detectors for medical radiography. Crystalline semiconductor will be bonded to a pixellated readout chip where individual integrated circuits process each event, transferring the position, energy and timing information to the data acquisition controller. Chips will be tiled to produce a large area detector, capable of energy dispersive photon counting at moderate spatial resolution. Preliminary results from studies examining the design features and operation of the device are presented

  19. Temperature measurement by neutron resonance radiography

    International Nuclear Information System (INIS)

    Mayers, J.; Baciocco, G.; Hannon, A.C.

    1988-03-01

    We present a new data analysis technique for obtaining temperatures from neutron resonance radiography measurements. The technique is applied to measurements on tantalum and rhenium foils, a high temperature engineering alloy and a model catalytic system. Temperatures have been obtained to an accuracy of better than ± 1 0 C in the temperature range 21 0 C to 600 0 C. The results are in good agreement with theoretical simulations. (author)

  20. Image distortion in rotational panoramic radiography. V

    International Nuclear Information System (INIS)

    Tronje, G.

    1982-01-01

    A theoretic analysis of the distortion and displacement of the inner structures of three-dimensional objects in panoramic films has been performed. Mathematical calculations were carried out of the distortion of model structures simulating structural details in an object. Although the model structures are affected by the distortion effects inherent in rotational panoramic radiography, the panoramic film still gives a recognizable image of the inner structure of an object. (Auth.)