WorldWideScience

Sample records for induction generator connected

  1. Analysis and estimation of transient stability for a grid-connected wind turbine with induction generator

    DEFF Research Database (Denmark)

    Li, H.; Zhao, B.; Yang, C.

    2011-01-01

    based on normal form theory is proposed. The transient models of the wind turbine generation system including the flexible drive train model are derived based on the direct transient stability estimation method. A method of critical clearing time (CCT) calculation is developed for the transient......Increasing levels of wind energy in modern electrical power system is initiating a need for accurate analysis and estimation of transient stability of wind turbine generation systems. This paper investigates the transient behaviors and possible direct methods for transient stability evaluation...... of a grid-connected wind turbine with squirrel cage induction generator (SCIG). Firstly, by using an equivalent lump mass method, a three-mass wind turbine equivalent model is proposed considering both the blades and the shaft flexibility of the wind turbine drive train system. Combined with the detailed...

  2. Grid-connected in-stream hydroelectric generation based on the doubly fed induction machine

    Science.gov (United States)

    Lenberg, Timothy J.

    Within the United States, there is a growing demand for new environmentally friendly power generation. This has led to a surge in wind turbine development. Unfortunately, wind is not a stable prime mover, but water is. Why not apply the advances made for wind to in-stream hydroelectric generation? One important advancement is the creation of the Doubly Fed Induction Machine (DFIM). This thesis covers the application of a gearless DFIM topology for hydrokinetic generation. After providing background, this thesis presents many of the options available for the mechanical portion of the design. A mechanical turbine is then specified. Next, a method is presented for designing a DFIM including the actual design for this application. In Chapter 4, a simulation model of the system is presented, complete with a control system that maximizes power generation based on water speed. This section then goes on to present simulation results demonstrating proper operation.

  3. Differential Evolution Based IDWNN Controller for Fault Ride-Through of Grid-Connected Doubly Fed Induction Wind Generators.

    Science.gov (United States)

    Manonmani, N; Subbiah, V; Sivakumar, L

    2015-01-01

    The key objective of wind turbine development is to ensure that output power is continuously increased. It is authenticated that wind turbines (WTs) supply the necessary reactive power to the grid at the time of fault and after fault to aid the flowing grid voltage. At this juncture, this paper introduces a novel heuristic based controller module employing differential evolution and neural network architecture to improve the low-voltage ride-through rate of grid-connected wind turbines, which are connected along with doubly fed induction generators (DFIGs). The traditional crowbar-based systems were basically applied to secure the rotor-side converter during the occurrence of grid faults. This traditional controller is found not to satisfy the desired requirement, since DFIG during the connection of crowbar acts like a squirrel cage module and absorbs the reactive power from the grid. This limitation is taken care of in this paper by introducing heuristic controllers that remove the usage of crowbar and ensure that wind turbines supply necessary reactive power to the grid during faults. The controller is designed in this paper to enhance the DFIG converter during the grid fault and this controller takes care of the ride-through fault without employing any other hardware modules. The paper introduces a double wavelet neural network controller which is appropriately tuned employing differential evolution. To validate the proposed controller module, a case study of wind farm with 1.5 MW wind turbines connected to a 25 kV distribution system exporting power to a 120 kV grid through a 30 km 25 kV feeder is carried out by simulation.

  4. Differential Evolution Based IDWNN Controller for Fault Ride-Through of Grid-Connected Doubly Fed Induction Wind Generators

    Directory of Open Access Journals (Sweden)

    N. Manonmani

    2015-01-01

    Full Text Available The key objective of wind turbine development is to ensure that output power is continuously increased. It is authenticated that wind turbines (WTs supply the necessary reactive power to the grid at the time of fault and after fault to aid the flowing grid voltage. At this juncture, this paper introduces a novel heuristic based controller module employing differential evolution and neural network architecture to improve the low-voltage ride-through rate of grid-connected wind turbines, which are connected along with doubly fed induction generators (DFIGs. The traditional crowbar-based systems were basically applied to secure the rotor-side converter during the occurrence of grid faults. This traditional controller is found not to satisfy the desired requirement, since DFIG during the connection of crowbar acts like a squirrel cage module and absorbs the reactive power from the grid. This limitation is taken care of in this paper by introducing heuristic controllers that remove the usage of crowbar and ensure that wind turbines supply necessary reactive power to the grid during faults. The controller is designed in this paper to enhance the DFIG converter during the grid fault and this controller takes care of the ride-through fault without employing any other hardware modules. The paper introduces a double wavelet neural network controller which is appropriately tuned employing differential evolution. To validate the proposed controller module, a case study of wind farm with 1.5 MW wind turbines connected to a 25 kV distribution system exporting power to a 120 kV grid through a 30 km 25 kV feeder is carried out by simulation.

  5. Improved direct torque control of an induction generator used in a wind conversion system connected to the grid.

    Science.gov (United States)

    Abdelli, Radia; Rekioua, Djamila; Rekioua, Toufik; Tounzi, Abdelmounaïm

    2013-07-01

    This paper presents a modulated hysteresis direct torque control (MHDTC) applied to an induction generator (IG) used in wind energy conversion systems (WECs) connected to the electrical grid through a back-to-back converter. The principle of this strategy consists in superposing to the torque reference a triangular signal, as in the PWM strategy, with the desired switching frequency. This new modulated reference is compared to the estimated torque by using a hysteresis controller as in the classical direct torque control (DTC). The aim of this new approach is to lead to a constant frequency and low THD in grid current with a unit power factor and a minimum voltage variation despite the wind variation. To highlight the effectiveness of the proposed method, a comparison was made with classical DTC and field oriented control method (FOC). The obtained simulation results, with a variable wind profile, show an adequate dynamic of the conversion system using the proposed method compared to the classical approaches. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  6. Response of MV-connected Doubly-Fed Induction Generator Wind Turbines and CHP plants to Grid Disturbances

    NARCIS (Netherlands)

    Karaliolios, P.; Slootweg, J.G.; Kling, W.L.

    2010-01-01

    Notwithstanding the positive environmental impact, the increasing penetration of Distributed Generation (DG) units connected to the distribution network raises new topics concerning the expected response of these during outages. Grid disturbances especially at the transmission level can cause the

  7. A solar PV augmented hybrid scheme for enhanced wind power generation through improved control strategy for grid connected doubly fed induction generator

    Directory of Open Access Journals (Sweden)

    Adikanda Parida

    2016-12-01

    Full Text Available In this paper, a wind power generation scheme using a grid connected doubly fed induction generator (DFIG augmented with solar PV has been proposed. A reactive power-based rotor speed and position estimation technique with reduced machine parameter sensitivity is also proposed to improve the performance of the DFIG controller. The estimation algorithm is based on model reference adaptive system (MRAS, which uses the air gap reactive power as the adjustable variable. The overall generation reliability of the wind energy conversion system can be considerably improved as both solar and wind energy can supplement each other during lean periods of either of the sources. The rotor-side DC-link voltage and active power generation at the stator terminals of the DFIG are maintained constant with minimum storage battery capacity using single converter arrangement without grid-side converter (GSC. The proposed scheme has been simulated and experimentally validated with a practical 2.5 kW DFIG using dSPACE CP1104 module which produced satisfactory results.

  8. Distributed generation induction and permanent magnet generators

    CERN Document Server

    Lai, L

    2007-01-01

    Distributed power generation is a technology that could help to enable efficient, renewable energy production both in the developed and developing world. It includes all use of small electric power generators, whether located on the utility system, at the site of a utility customer, or at an isolated site not connected to the power grid. Induction generators (IGs) are the cheapest and most commonly used technology, compatible with renewable energy resources. Permanent magnet (PM) generators have traditionally been avoided due to high fabrication costs; however, compared with IGs they are more reliable and productive. Distributed Generation thoroughly examines the principles, possibilities and limitations of creating energy with both IGs and PM generators. It takes an electrical engineering approach in the analysis and testing of these generators, and includes diagrams and extensive case study examples o better demonstrate how the integration of energy sources can be accomplished. The book also provides the ...

  9. Transient analysis of a grid connected wind driven induction generator using a real-time simulation platform

    Energy Technology Data Exchange (ETDEWEB)

    Ouhrouche, Mohand [Department of Applied Sciences, University of Quebec at Chicoutimi, Quebec, G7H2B1 (Canada)

    2009-03-15

    Due to its simple construction, ruggedness and low cost, the induction generator driven by a wind turbine and feeding power to the grid appears to be an attractive solution to the problem of growing energy demand in the context of environmental issues. This paper investigates the integration of such a system into the main utility using RT-Lab trademark (Trademark of Opal-RT Technologies) software package running on a simple off-the-shelf PC. This real-time simulation platform is now adopted by many high-tech industries as a real-time laboratory package for rapid control prototyping and for Hardware-in-the-Loop applications. Real-time digital simulation results obtained during contingencies, such as islanding and unbalanced faults are presented and analysed. (author)

  10. Inductive line energy storage generator

    Energy Technology Data Exchange (ETDEWEB)

    Choi, P [Ecole Polytechnique, Palaiseau (France). Laboratoire de Physique des Milieux Ionises

    1997-12-31

    The inductive energy storage (IES) generator has long been considered to be the most efficient system for energy usage in large pulsed power system at the MA level. A number of parameters govern the efficiency of energy transfer between the storage capacitors and the load, and the level of current deliverable to the load. For high power system, the energy storage capacitors are arranged as a Marx generator. The primary constraints are the inductances in the various parts of the circuit, in particular, the upstream inductance between the Marx and the POS, and the downstream inductance between the POS and the load. This paper deals with the effect of replacing part of the upstream inductance with a transmission line and introduces the new concept of an inductive line for energy storage (ILES). Extensive parametric scans were carried out on circuit simulations to investigate the effect of this upstream transmission line. A model was developed to explain the operation of the ILES design based on the data obtained. Comparison with an existing IES generator shows that the ILES design offers a significant improvement in the maximum current and hence energy delivered to an inductive load. (author). 5 figs., 1 ref.

  11. The Always-Connected Generation

    Science.gov (United States)

    Bull, Glen

    2010-01-01

    The Pew Internet and American Life project characterizes the millennials--the first generation to come of age in the new millennium--as the first "always-connected" generation. Significant aspects of culture are changing as a result. A changing world where all students are connected all the time has substantial educational implications. Despite…

  12. Operating of Small Wind Power Plants with Induction Generators

    Directory of Open Access Journals (Sweden)

    Jakub Nevrala

    2008-01-01

    Full Text Available This paper describes different systems of small wind power plants with induction generators used in the Czech Republic. Problems of wind power plants running with induction generators are solved within partial target of the research project MSM 6198910007. For small wind power plants is used induction motor as a generator. Parameters of the name plate of motor must be resolved for generator running on measuring base. These generators are running as a separately working generators or generators connected to the power grid. Methods of control these systems as a separately working, directly connecting to power grid, control by frequency converter and wiring by synchronous cascade are confronted on the measuring base too.

  13. Modeling and analysis with induction generators

    CERN Document Server

    Simões, M Godoy

    2014-01-01

    ForewordPrefaceAcknowledgmentsAuthorsPrinciples of Alternative Sources of Energy and Electric GenerationScope of This ChapterLegal DefinitionsPrinciples of Electrical ConversionBasic Definitions of Electrical PowerCharacteristics of Primary SourcesCharacteristics of Remote Industrial, Commercial, and Residential Sites and Rural EnergySelection of the Electric GeneratorInterfacing Primary Source, Generator, and LoadExample of a Simple Integrated Generating and Energy-Storing SystemSolved ProblemsSuggested ProblemsReferencesSteady-State Model of Induction GeneratorsScope of This ChapterInterconnection and Disconnection of the Electric Distribution NetworkRobustness of Induction GeneratorsClassical Steady-State Representation of the Asynchronous MachineGenerated PowerInduced TorqueRepresentation of Induction Generator LossesMeasurement of Induction Generator ParametersBlocked Rotor Test (s = 1)No-Load Test (s = 0)Features of Induction Machines Working as Generators Interconnected to the Distribution NetworkHigh-...

  14. Power generation using photovoltaic induction in an isolated power network

    International Nuclear Information System (INIS)

    Kalantar, M.; Jiang, J.

    2001-01-01

    Owing to increased emphasis on renewable resources, the development of suitable isolated power generators driven by energy sources, the development of suitable isolated power generators driven by energy sources such as photovoltaic, wind, small hydroelectric, biogas and etc. has recently assumed greater significance. A single phase capacitor self excited induction generator has emerged as a suitable candidate of isolated power sources. This paper presents performance analysis of a single phase self-excited induction generator driven by photovoltaic (P V) system for low power isolated stand-alone applications. A single phase induction machine can work as a self-excited induction generator when its rotor is driven at suitable speed by an photovoltaic powered do motor. Its excitation is provided by connecting a single phase capacitor bank at a stator terminals. Either to augment grid power or to get uninterrupted power during grid failure stand-alone low capacity ac generators are used. These are driven by photovoltaic, wind power or I C engines using kerosene, diesel, petrol or biogas as fuel. Self-excitation with capacitors at the stator terminals of the stator terminals of the induction machines is well demonstrated experimentally on a P V powered dc motor-induction machine set. The parameters and the excitation requirements of the induction machine run in self-excited induction generator mode are determined. The effects of variations in prime mover speed,terminal capacitance and load power factor on the machine terminal voltage are studied

  15. ANALYSIS OF PROCESSES IN AN INDEPENDENT GENERATOR WITH A NONCONTACT CASCADE THREE-PHASE MODULATED EXCITER VIA A STAR-CONNECTED CIRCUIT WITH A COMMON MODULATOR PHASE CONNECTION UNDER OPERATION TO AN INDUCTION MOTORS SITE

    Directory of Open Access Journals (Sweden)

    K.M. Vasyliv

    2013-04-01

    Full Text Available By means of a mathematical experiment, electromagnetic and electromechanical processes in an independent electric power supply system based on an asynchronized generator with a three-phase modulated exciter are investigated. The processes are analyzed to specify the working capacity of the power supply system during its operation to an induction motors site. Regularities of the electromagnetic and electromechanical processes behavior versus load intensity and the switch control system parameters are identified.

  16. 1 MV low-induction pulse generator

    International Nuclear Information System (INIS)

    Koba, G.I.; Koba, Yu.V.; Slivkov, I.N.; Sukhov, A.D.; Tarumov, Eh.Z.

    1980-01-01

    A high-voltage pulse generator is described. The generator Uses the Arkadiev-Marx circuit at 1 MV voltage and 12 kJ energy; the inductance of the discharge circuit is 1.3 μN. Low inductance of the generator has been obtained due to the use of low-inductance capacitors and employment of bifilar buses with oil barrier insulation. To provide reliable generator triggering, an ignition circuit has been developed with a resistive coupling between generator steps, based on controlled three-electrode sparkgaps with a distorted field. The generator switching time is slightly dependent on pressure and constitutes 200-300 ns. The generator efficiency is 83%

  17. Induction generator models in dynamic simulation tools

    DEFF Research Database (Denmark)

    Knudsen, Hans; Akhmatov, Vladislav

    1999-01-01

    For AC network with large amount of induction generators (windmills) the paper demonstrates a significant discrepancy in the simulated voltage recovery after fault in weak networks when comparing dynamic and transient stability descriptions and the reasons of discrepancies are explained...

  18. Induction generator-induction motor wind-powered pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, M.S.; Lyra, R.O.C.; Silva, S.R. [CPDEE - UFMG, Belo Horizonte (Brazil)

    1997-12-31

    The energy storage matter plays an important role in wind-electric conversion systems for isolated applications. Having that in mind, two different approaches can be basically considered: either the immediate conversion of the generated electric energy, as in a water pumping system or electric energy storage for later use, as in a battery charging system. Due to some features such as no need of an external reactive power source and, sometimes, a gearbox, permanent-magnet synchronous generators have been broadly used in low rated power isolated systems. Despite that, system performance can be affected when the generator is feeding an inductive load (e.g., an induction motor) under variable-speed-variable-frequency operational conditions. Since there is no effective flux control, motor overload may occur at high wind speeds. Thus, good system performance can be obtained through additional control devices which may increase system cost. Although being rugged and cheap, induction machines always work as a reactive power drain; therefore, they demand an external reactive power source. Considering that, reactive static compensators appear as an attractive alternative to the cost x performance problem. In addition to that, different control strategies can be used so that system performance can be improved.

  19. Operating of Small Wind Power Plants with Induction Generators

    OpenAIRE

    Jakub Nevrala; Stanislav Misak

    2008-01-01

    This paper describes different systems of small wind power plants with induction generators used in the Czech Republic. Problems of wind power plants running with induction generators are solved within partial target of the research project MSM 6198910007. For small wind power plants is used induction motor as a generator. Parameters of the name plate of motor must be resolved for generator running on measuring base. These generators are running as a separately working generators or generator...

  20. Crowbar System in Doubly Fed Induction Wind Generators

    Directory of Open Access Journals (Sweden)

    Maurício B. C. Salles

    2010-04-01

    Full Text Available In the last 15 years, the use of doubly fed induction machines in modern variable-speed wind turbines has increased rapidly. This development has been driven by the cost reduction as well as the low-loss generation of Insulated Gate Bipolar Transistors (IGBT. According to new grid code requirements, wind turbines must remain connected to the grid during grid disturbances. Moreover, they must also contribute to voltage support during and after grid faults. The crowbar system is essential to avoid the disconnection of the doubly fed induction wind generators from the network during faults. The insertion of the crowbar in the rotor circuits for a short period of time enables a more efficient terminal voltage control. As a general rule, the activation and the deactivation of the crowbar system is based only on the DC-link voltage level of the back-to-back converters. In this context, the authors discuss the critical rotor speed to analyze the instability of doubly fed induction generators during grid faults.

  1. Banding of connection standards for distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-05-04

    This report presents the views of distributed network operators (DNOs), developers, equipment manufacturers and consultants on the current banding of distributed generation in terms of connection standards and recommendations. The Documents ER G59/1, ER G75/1, ER G83/1 and ETR 113/1 covering recommendations for the connection of embedded generating plant to distribution systems and guidance notes for the protection of embedded generating plant are examined. The way in which the recommendations are applied in practice is investigated. Multiple distribution generator installations, fault ride through, and banding are considered as well as both protection required and maximum generator sizes at respective voltage levels.

  2. A COMPARATIVE ANALYSIS OF PROCESSES IN AN INDEPENDENT GENERATOR WITH A NONCONTACT CASCADE THREE-PHASE MODULATED EXCITER VIA A STAR-CONNECTED CIRCUIT UNDER ACTIVE-INDUCTIVE LOADING

    Directory of Open Access Journals (Sweden)

    K.M. Vasyliv

    2013-02-01

    Full Text Available By means of mathematical experiment, the author investigates electromagnetic and electromechanical processes in an independent electric power supply system based on an asynchronized generator with a three-phase modulated exciter. The processes are analyzed to specify the working capacity of the power supply system during its operation under active-inductive loading. Regularities of the electromagnetic and electromechanical processes behavior versus load intensity and the modulator scheme are identified.

  3. Neural network based control of Doubly Fed Induction Generator in wind power generation

    Science.gov (United States)

    Barbade, Swati A.; Kasliwal, Prabha

    2012-07-01

    To complement the other types of pollution-free generation wind energy is a viable option. Previously wind turbines were operated at constant speed. The evolution of technology related to wind systems industry leaded to the development of a generation of variable speed wind turbines that present many advantages compared to the fixed speed wind turbines. In this paper the phasor model of DFIG is used. This paper presents a study of a doubly fed induction generator driven by a wind turbine connected to the grid, and controlled by artificial neural network ANN controller. The behaviour of the system is shown with PI control, and then as controlled by ANN. The effectiveness of the artificial neural network controller is compared to that of a PI controller. The SIMULINK/MATLAB simulation for Doubly Fed Induction Generator and corresponding results and waveforms are displayed.

  4. Stability improvement of induction generator-based wind turbine systems

    DEFF Research Database (Denmark)

    Chen, Zhe; Hu, Y.; Blaabjerg, Frede

    2007-01-01

    The stability improvement of induction-generator-based wind turbine systems under power system fault conditions has been studied. Two types of generators are considered, namely rotor short-circuited induction generators and dynamic slip-controlled wound rotor induction generators. The factors...... affecting the stability are analysed. The characteristics of the induction-generator-based wind turbines are described, and possible methods of improving stability of the wind generators are discussed. The system modelling is presented, and then the discussed methods of improving stability are investigated...

  5. Investigation of torque control using a variable slip induction generator

    Energy Technology Data Exchange (ETDEWEB)

    Bossanyi, E A; Gamble, C R

    1991-07-01

    An investigation of the possibilities of using a variable slip induction generator to control wind turbine transmission torque has been carried out. Such a generator consists of a wound rotor induction generator with its rotor winding connected to an external variable resistance circuit. By controlling the external resistance, the torque-slip characteristic of the generator can be modified, allowing efficient, low-slip operation below rated wind speed and compliant, high-slip operation above rated, where the additional losses are of no consequence but the resulting compliance allows a much reduced duty to be specified for the transmission and gearbox. A number of hardware options have been investigated for the variable resistance rotor circuit, the main options being either a rectifier and DC chopper or an AC regulator. Both of these options use semiconductor switching devices, for which the relative merits of thyristors, MOSFETs, GTOs and transistors have been investigated. A favoured scheme consisting of an AC regulator using GTOs has been provisionally selected. This choice uses some non-standard equipment but is expected to give negligible problems with harmonics. A comprehensive simulation model has been set up and used to investigate the behaviour of the whole system. (author).

  6. Stand-alone induction generators for small water power schemes

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Adam [Intermediate Technology Development Group, Rugby (United Kingdom); Smith, Nigel [Smith Associates, Nottingham (United Kingdom)

    1996-04-01

    Conventional technology for isolated power generation is the synchronous generator. Using stand-alone induction generators has proved to have tremendous advantages in remote regions of developing countries, where electricity has significant social benefits. (author)

  7. Pulsed power generators using an inductive energy storage system

    International Nuclear Information System (INIS)

    Akiyama, H.; Sueda, T.; Katschinski, U.; Katsuki, S.; Maeda, S.

    1996-01-01

    The pulsed power generators using an inductive energy storage system are extremely compact and lightweight in comparison with those using a capacitive energy storage system. The reliable and repetitively operated opening switch is necessary to realize the inductive pulsed power generator. Here, the pulsed power generators using the inductive energy storage system, which have been developed in Kumamoto University, are summarized. copyright 1996 American Institute of Physics

  8. Internet services for planning distributed generation connections

    Energy Technology Data Exchange (ETDEWEB)

    Curry, D.; Morgan, A.; Barbier, C.; Reay, P.

    2005-07-01

    The required publication by distributed network operators (DNOs) of details of the current state of their network systems and future planned developments in the form of Long Term Development Statements (LTDS) are discussed. This project aims to increase the usefulness of the information in the LTDS by making it available on the internet and by providing an initial assessment of connection opportunities and the possibility of viewing existing renewable generation projects. The services developed covered data loading, data visualisation, security, connection assessment, reporting, and generation site registration. The benefits of an electronic version of the LTDS are highlighted.

  9. Dynamics of 'abc' and 'qd' constant parameters induction generator model

    DEFF Research Database (Denmark)

    Fajardo-R, L.A.; Medina, A.; Iov, F.

    2009-01-01

    In this paper, parametric sensibility effects on dynamics of the induction generator in the presence of local perturbations are investigated. The study is conducted in a 3x2 MW wind park dealing with abc, qd0 and qd reduced order, induction generator model respectively, and with fluxes as state...

  10. Micro-generation network connection (renewables)

    Energy Technology Data Exchange (ETDEWEB)

    Thornycroft, J.; Russell, T.; Curran, J.

    2003-07-01

    The drive to reduce emissions of carbon dioxide will result in an increase in the number of small generation units seeking connection to the electric power distribution network. The objectives of this study were to consider connection issues relating to micro-generation from renewables and their integration into the UK distribution network. The document is divided into two sections. The first section describes the present system which includes input from micro-generation, the technical impacts and the financial considerations. The second part discusses technical, financial and governance options for the future. A summary of preferred options and recommendations is given. The study was carried out by the Halcrow Group Ltd under contract to the DTI.

  11. Theoretical and experimental analysis of the induction generators; Analise teorica e experimental do gerador de inducao

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Marcel; Martins Neto, Luciano; Calixto, Wesley Pacheco; Gontijo, Andre Luiz; Alves, Aylton Jose [Universidade Federal de Uberlandia (LMEE/FEELT/UFU), MG (Brazil). Fac. de Engenharia Eletrica. Lab. de Maquinas Eletricas Especiais], E-mails: marcel@mestrado.ufu.br, lmn@ufu.br, wpcalixto@ieee.org, aja@cefetgo.br

    2009-10-15

    Due to its lower costs, robustness, reduced maintenance and easy operation, the induction generator shows to be an economic alternative in small power generator systems. This work presents the initial phase of pertinent studies about the employment of the induction generator directly connected to the electrical power grid in a pilot project to be implemented at the Santa Luzia SHP. A project that aims to raise relevant operational aspects and to evidence some advantages about the employment of the induction generator in small power generator systems. This phase comprises the experimentation of an induction generator directly connected to the power grid in a laboratorial scale, plus a computational modeling which represents the same. This computational modeling takes into account loads variations which are being supplied by the generator, unbalance between phases and magnetic saturation effects, such as harmonic distortions in the generated currents. From the experimental model collected data, a theoretical-experimental confrontation of the computational modeling is made, where quantitative and qualitative analyses about the operational characteristics of the machine are made. The results of this work will head the operation and supervision of the SHP induction machine. (author)

  12. Yield and power of the induction motor operating as generator; Rendimento e potencia do motor de inducao atuando como gerador

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Francisco de Salles Cintra [Universidade Paulista (UNIP), Campinas, SP (Brazil)

    1997-12-01

    This article shows the result of the analysis of two induction motors operating as generators (Park variable for a machine connected to an infinite bar), particularly the yield and power of the machines operating under this condition.

  13. A class of flux observers for doubly-fed induction generators used in small power wind generation systems

    DEFF Research Database (Denmark)

    Lascu, C.; Boldea, I.; Blaabjerg, Frede

    2013-01-01

    This paper investigates a family of stator and rotor flux observers for sensorless operation of doubly-fed induction generators (DFIG). Four stator flux observer topologies are described and compared. All proposed schemes use the voltage and current models connected in parallel or in series...

  14. A novel proposal of cooperation between a cage induction generator and the three-phase grid

    Directory of Open Access Journals (Sweden)

    Szular Zbigniew

    2016-01-01

    Full Text Available In the paper, a new concept of the cooperation between a cage induction generator and the three-phase grid is presented. The induction generator is excited by a capacitor battery connected to the stator winding terminals. In order to ensure a stable operation, the battery capacity should be continuously adjusted. Three appropriate selected capacitors are connected to the stator winding terminals by means of two bi-directional controlled switches. The generator output voltage is stabilized by a suitable control of these switches. The stator winding terminals are also connected to the diode bridge rectifier. Energy in the DC bus is converted to the parameters of the three-phase grid (400 V, 50 Hz by means of a three-phase voltage source inverter. Examples of numerical calculation results of the proposed energy generation system are presented in the end part of the paper.

  15. Non-inductive electric current generation with the Alfven waves

    International Nuclear Information System (INIS)

    Assis, A.S. de.

    1988-01-01

    Non-inductive current generation by means of radio frequency waves is studied using one-dimensional (1D) quasilinear equations. The main results obtained in this thesis are the general expressions for the current generated, for the efficiency of current generation and for the critical power - the lowest power required for current saturation. (M.W.O.) [pt

  16. Internet services for planning embedded generation connections

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-12-15

    The required publication by distributed network operators (DNOs) of details of the current state of their network systems and future planned developments in the form of Long Term Development Statements (LTDS) are discussed. This project aims to increase the usefulness of the information in the LTDS by making it available on the internet, by transforming LTDSs into electronic format, and integrating LTDS information with geographical information in a single database. Services developed provide for data loading, data visualisation, initial assessment of connection opportunities, and reporting. The benefits of the services, and the demonstrated feasibility of publishing information concerning UK renewable generation sites are considered. The web address of the site is given.

  17. Doubly-Fed Induction Generator Control Under Voltage Sags

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Blaabjerg, Frede; Lima, K.

    2008-01-01

    This paper proposes a new control technique to improve the fault-ride through capability of doubly fed induction generators (DFIG). In such generators the appearance of severe voltage sags at the coupling point make rise to high over currents at the rotor/stator windings, something that makes...

  18. Controller for a small induction-generator based wind-turbine

    Energy Technology Data Exchange (ETDEWEB)

    Ahshan, R.; Iqbal, M.T.; Mann, George K.I. [Faculty of Engineering and Applied Science, Memorial University of Newfoundland, St. John' s, Newfoundland (Canada)

    2008-04-15

    Design of a low-cost micro-controller for a small induction-generator based grid-connected wind-turbine is presented in this paper. The controller senses the parameters of the wind-turbine generator and the grid, and makes decisions about grid connection and disconnection. Low-cost instrumentation circuitry has been developed to measure the generator and grid parameters. Based on the measurement of voltage and frequency of the wind-turbine generator and the grid side, a control decision is taken to connect the system to the grid. The controller makes decision to disconnect the system from the grid based on the power flow measurement between the wind turbine and the grid. The power flow between wind turbine and the grid depends upon the availability of the wind. The prototype controller has been developed based on a micro-controller PIC16F877 and has been tested in the laboratory. (author)

  19. Control of variable speed wind turbine with doubly-fed induction generator

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, A.D.; Soerensen, P. [Risoe National Lab., Wind Energy Dept., Roskilde (Denmark); Iov, F.; Blaabjerg, F. [Aalborg Univ., Inst. of Energy Technology, Aalborg (Denmark)

    2004-07-01

    draIn this paper, a Control method suitable for a variable speed grid connected pitch-controlled wind turbine with doubly-fed induction generator (DFIG) is developed. The targets of the Control system are: 1) to Control the power drawn from the wind turbine in order to track the wind turbine optimum operation point 2) to limit the power in case of high wind speeds and 3) to Control the reactive power interchanged between the wind turbine generator and the grid. The considered configuration of DFIG is an induction generator with a wound rotor connected to the grid through a back-to-back power converter and a stator directly connected to the grid. The paper presents the overall Control system of the variable speed DFIG wind turbine, with focus on the Control strategies and algorithms applied at each hierarchical Control level of the wind turbine. There are two Control levels: a DFIG Control level and wind turbine Control level. The DFIG Control level contains a fast Control of the power converter and of the doubly-fed induction generator and it has as goal to Control the active and reactive power of the wind turbine independently. The wind turbine Control level supervises with Control signals both the DFIG Control level and the hydraulic pitch Control system of the wind turbine. The present Control method is designed for normal continuous operations. The variable speed/variable pitch wind turbine with doubly-fed induction generator is implemented in the dynamic power system simulation tool DIgSILENT, which makes possible to investigate the dynamic performance of gid-connected wind turbines as a part of realistic electrical grid models. Several significant simulation results are performed With the overall Control-implemented algorithm applied on a variable speed, variable pitch wind turbine model. (au)

  20. Improving Casing Integrity by Induction Brazing of Casing Connections

    NARCIS (Netherlands)

    Ernens, Dennis; Hariharan, Hari; van Haaften, Willem Maarten; Pasaribu, Rihard; Jabs, Matthew; McKim, Richard

    2017-01-01

    Brazing technology allows metallurgical joining of dissimilar materials using a filler material. In this paper brazing technology applied to casing connections is presented. The initial application was triggered by challenges with mechanical and pressure integrity after expansion of casing

  1. Induction Generators for Direct-Drive Wind Turbines

    DEFF Research Database (Denmark)

    Henriksen, Matthew Lee; Jensen, Bogi Bech

    2011-01-01

    This paper considers the use of a squirrel cage induction generator for a direct-drive wind turbine. Advantages of this topology include a simple/rugged construction, and no need for permanent magnets. A major focus of this paper is the choice of an appropriate pole number. An iterative, analytical...

  2. Process for the generation of high capacity pulses from an inductive energy storage device

    International Nuclear Information System (INIS)

    Maier, F.; Maier, S.

    1984-01-01

    An inductive storage circuit for generating high voltage pulses includes a quenching circuit and a discharge circuit each connected in parallel with a storage inductor. One branch of the quenching circuit includes a quenching capacitor and one branch of the discharge circuit includes a resistor and a diode in series. These two branches have a common junction, to which is connected a quenching thyristor that forms the second branch of each of the quenching and discharge circuits. Thus, the quenching thyristor is in series with each of the quenching capacitor and the discharge resistor

  3. Modelling of windmill induction generators in dynamic simulation programs

    DEFF Research Database (Denmark)

    Akhmatov, Vladislav; Knudsen, Hans

    1999-01-01

    with and without a model of the mechanical shaft. The reason for the discrepancies are explained, and it is shown that the phenomenon is due partly to the presence of DC offset currents in the induction machine stator, and partly to the mechanical shaft system of the wind turbine and the generator rotor......For AC networks with large amounts of induction generators-in case of e.g. windmills-the paper demonstrates a significant discrepancy in the simulated voltage recovery after faults in weak networks, when comparing result obtained with dynamic stability programs and transient programs, respectively....... It is shown that it is possible to include a transient model in dynamic stability programs and thus obtain correct results also in dynamic stability programs. A mechanical model of the shaft system has also been included in the generator model...

  4. Inductive energy store (IES) technology for multi-terrawatt generators

    International Nuclear Information System (INIS)

    Sincerny, P.S.; Ashby, S.R.; Childers, F.K.; Deeney, C.; Kortbawi, D.; Goyer, J.R.; Riordan, J.C.; Roth, I.S.; Stallings, C.; Schlitt, L.

    1993-01-01

    An IES pulsed power machine has been built at Physics International Company that serves as a prototype demonstration of IES technology that is scaleable to very large TW generators. The prototype module utilizes inductive store opening switch technology for the final stage of pulse compression and is capable of driving both electron beam Bremsstrahlung loads or imploding plasma loads. Each module consists of a fast discharge Marx driving a water dielectric transfer capacitor which is command triggered to drive the inductive store section of the machine. The inductive store is discharged into the load using a plasma erosion opening switch. Data demonstrating 22% efficient operation into an electron beam diode load are presented. The system issues addressing the combining of these modules into a very large pulsed power machine are discussed

  5. A Vertical-Axis Off-Grid Squirrel-Cage Induction Generator Wind Power System

    Directory of Open Access Journals (Sweden)

    Peifeng Xu

    2016-10-01

    Full Text Available In order to broaden the limited utilization range of wind power and improve the charging and discharging control performance of the storage battery in traditional small wind power generation systems, a wind power system based on a vertical-axis off-grid induction generator is proposed in this paper. The induction generator not only can run in a wide wind speed range but can also assist the vertical-axis wind turbine to realize self-starting at low wind speed. Combined with the maximum power point tracking method, the slip frequency control strategy is employed to regulate the pulse width modulation (PWM converter to control the output power of the proposed system when the wind speed and load change. The charge and discharge of the storage battery is realized by the segmented current-limiting control strategy by means of an electric power unloader device connected to the DC bus. All these implement a balanced and stable operation of the proposed power generation system. The experimental research on the 5.5 kW prototype system is developed, and the corresponding results verify the correctness and feasibility of the system design and control strategy. Some comparison experiments with a magnetic suspension permanent magnet synchronous generator (PMSG demonstrate the application prospect of the proposed vertical-axis off-grid induction generator wind power system.

  6. Flicker Mitigation Strategy for a Doubly Fed Induction Generator by Torque Control

    DEFF Research Database (Denmark)

    Zhang, Yunqian; Hu, Weihao; Chen, Zhe

    2014-01-01

    induction generator is presented to investigate the flicker mitigation. Taking advantage of the large inertia of the wind turbine rotor, a generator torque control (GTC) strategy is proposed, so that the power oscillation is stored as the kinetic energy of the wind turbine rotor, thus the flicker emission...... is an effective means for flicker mitigation of variable speed wind turbines during continuous operation.......Owing to the rotational sampling of turbulence, wind shear and tower shadow effects grid connected variable speed wind turbines could lead to the power fluctuations which may produce flicker during continuous operation. A model of an megawatt (MW)-level variable speed wind turbine with a doubly fed...

  7. Study of non inductive current generation in a plasma

    International Nuclear Information System (INIS)

    Rax, J.M.

    1987-01-01

    The problem of non-thermal bremsstrahlung during lower hybrid current drive is considered. The proposed method shows the role of the Compton effects at low frequencies and allows us to establish the link between the emitted power and the absorbed power at high frequency. The non-thermal emission is considered as a kinematical mode conversion between the absorbed radio-frequency mode and the emitted X ray photons. The fast electrons diagnostics and the ways to reach the wave structure are shown. Kinetic and electromagnetic problems concerning current generation are described. The plasma properties and diagnostics in the case of a non inductive current generation are discussed [fr

  8. A neural model of rule generation in inductive reasoning.

    Science.gov (United States)

    Rasmussen, Daniel; Eliasmith, Chris

    2011-01-01

    Inductive reasoning is a fundamental and complex aspect of human intelligence. In particular, how do subjects, given a set of particular examples, generate general descriptions of the rules governing that set? We present a biologically plausible method for accomplishing this task and implement it in a spiking neuron model. We demonstrate the success of this model by applying it to the problem domain of Raven's Progressive Matrices, a widely used tool in the field of intelligence testing. The model is able to generate the rules necessary to correctly solve Raven's items, as well as recreate many of the experimental effects observed in human subjects. Copyright © 2011 Cognitive Science Society, Inc.

  9. Control and Analysis for a Self-Excited Induction Generator for Wind Turbine and Electrolyzer Applications

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Na, Woonki [California State University, Fresno; Leighty, Bill [The Leighty Foundation; Kim, Jonghoon [Chungnam National University

    2017-12-14

    Self-Excited Induction Generation(SEIG) is very rugged, simple, lightweight, and it is easy and inexpensive to implement, very simple to control, and requires a very little maintenance. In this variable-speed operation, the SEIG needs a power electronics interface to convert from the variable frequency output voltage of the generator to a DC output voltage for battery or other DC applications. In our study, a SEIG is connected to the power electronics interface such as diode rectifier and DC/DC converter and then an electrolyzer is connected as a final DC load for fuel cell applications. An equivalent circuit model for an electrolyzer is utilized for our application. The control and analysis for the proposed system is carried out by using PSCAD and MATLAB software. This study would be useful for designing and control analysis of power interface circuits for SEIG for a variable speed wind turbine generation with fuel cell applications before the actual implementation.

  10. Modeling and Simulation of Generator Side Converter of Doubly Fed Induction Generator-Based Wind Power Generation System

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Blaabjerg, Frede

    2010-01-01

    A real wind power generation system is given in this paper. SVM control strategy and vector control is applied for generator side converter and doubly fed induction generator respectively. First the mathematical models of the wind turbine rotor, drive train, generator side converter are described...

  11. Dynamic Average-Value Modeling of Doubly-Fed Induction Generator Wind Energy Conversion Systems

    Science.gov (United States)

    Shahab, Azin

    In a Doubly-fed Induction Generator (DFIG) wind energy conversion system, the rotor of a wound rotor induction generator is connected to the grid via a partial scale ac/ac power electronic converter which controls the rotor frequency and speed. In this research, detailed models of the DFIG wind energy conversion system with Sinusoidal Pulse-Width Modulation (SPWM) scheme and Optimal Pulse-Width Modulation (OPWM) scheme for the power electronic converter are developed in detail in PSCAD/EMTDC. As the computer simulation using the detailed models tends to be computationally extensive, time consuming and even sometimes not practical in terms of speed, two modified approaches (switching-function modeling and average-value modeling) are proposed to reduce the simulation execution time. The results demonstrate that the two proposed approaches reduce the simulation execution time while the simulation results remain close to those obtained using the detailed model simulation.

  12. Flicker study on variable speed wind turbines with doubly fed induction generators

    DEFF Research Database (Denmark)

    Sun, Tao; Chen, Zhe; Blaabjerg, Frede

    2005-01-01

    to a conclusion that the factors mentioned above have different influences on flicker emission compared with that in the case of the fixed speed wind turbine. Flicker mitigation is realized by output reactive power control of the variable speed wind turbine with doubly fed induction generator. Simulation results...... show the wind turbine output reactive power control provides an effective means for flicker mitigation regardless of mean wind speed, turbulence intensity and short circuit capacity ratio.......Grid connected wind turbines may produce flicker during continuous operation. This paper presents a simulation model of a MW-level variable speed wind turbine with a doubly fed induction generator developed in the simulation tool of PSCAD/EMTDC. Flicker emission of variable speed wind turbines...

  13. Going smarter in the connection of distributed generation

    International Nuclear Information System (INIS)

    Anaya, Karim L.; Pollitt, Michael G.

    2017-01-01

    This study explores and quantifies the benefits of connecting more distributed generation (DG) with and without the use of smart connections in Great Britain. We examine the impacts on different parties (Distribution Network Operators, wider society and generators). As illustration we use a specific case study. Alternative connection scenarios are proposed (with partial and full interruptible capacity quota under a mix of generation with different technology-specific curtailment levels) for integrating DG units in a constrained area of the East of England covered by the Flexible Plug and Play project. The smart (interruptible) connection option is the preferred option across all the scenarios (higher NPV/MW). The analysis of the distribution of benefits between the different parties suggests that generators capture most of the benefits while DNOs and wider society capture much less benefit. A smart connection incentive, which recreates the benefits to DNOs from an earlier losses incentive, is proposed. By contrast with other societally desirable metrics which are usually incentivised or penalised, there is currently no direct connection between more DG MWs connected and DNO incentive payments. Our proposed smart connection incentive, by charging DG for smarter connection may help to distribute more efficiently the benefits for connecting more DG. - Highlights: • Three different dimensions of going smarter to connect DG are discussed. • Benefits for connecting DG in a constrained area (FPP project) are estimated. • Different DG connection scenarios are evaluated. • Generators benefit the most and wider society the least. • A smart connection incentive may help to reallocate the benefits of DG more efficiently.

  14. Comparison and analysis of transient performances for doubly fed induction generator wind turbine under grid voltage dip

    DEFF Research Database (Denmark)

    Li, H.; Ye, R.; Han, L.

    2010-01-01

    In order to entirely analyze the transient performances of a grid-connected doubly fed induction generator (DFIG) wind turbine under the different operational states, based on the transient models of DFIG, a two-mass wind turbine electrical equivalent model considering the torsional flexibility o...

  15. Loss Minimizing Operation of Doubly Fed Induction Generator Based Wind Generation Systems Considering Reactive Power Provision

    DEFF Research Database (Denmark)

    Baohua, Zhang; Hu, Weihao; Chen, Zhe

    2014-01-01

    The paper deals with control techniques for minimizing the operating loss of doubly fed induction generator based wind generation systems when providing reactive power. The proposed method achieves its goal through controlling the rotor side q-axis current in the synchronous reference frame...

  16. Modelling and simulation of multiple single - phase induction motor in parallel connection

    Directory of Open Access Journals (Sweden)

    Sujitjorn, S.

    2006-11-01

    Full Text Available A mathematical model for parallel connected n-multiple single-phase induction motors in generalized state-space form is proposed in this paper. The motor group draws electric power from one inverter. The model is developed by the dq-frame theory and was tested against four loading scenarios in which satisfactory results were obtained.

  17. INTERRAD - inductive terawatt X-ray generator (project)

    Energy Technology Data Exchange (ETDEWEB)

    Popkov, N F; Pikar` , A S; Kargin, V I; Ryaslov, E A; Lyubomirskij, A G [All-Russian Scientific Research Inst. of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    The results are given of the development and experimental research of explosive electron beam accelerator circuits powered by magneto-cumulative generators forming the current pulse, using explosive plasma opening switches. The conceptual lay-out of inductive terawatt X-ray generators powered by EMGs is proposed. The calculation results of the terawatt x-ray generator including the load placed in a special bunker are presented. Analyzed are the losses at the stage of the HE energy conversion into that of the magnetic fields, those occur ing in transmission along the high-voltage cable line, as well as the processes developing in the plasma opening switches. (author). 2 figs., 6 refs.

  18. Identification of voltage collapse point in self excited induction generator

    Directory of Open Access Journals (Sweden)

    Kalyanasundaram Rajambal

    2009-10-01

    Full Text Available This paper presents a direct equilibrium tracing method for identifying the voltage collapse point of a self-excitedinduction generator (SEIG without many trials. The technique solves differential and algebraic equations simultaneously toobtain the variables in a single step. The load parameter is also automatically varied during equilibrium tracing and thisreduces the computational time significantly. Comparing the simulation results obtained through conventional iterative procedure shows the effectiveness of the technique. An experimental verification on a 1.5KW induction machine validates the simulation results.

  19. Hybrid system power generation'wind-photovoltaic' connected to the ...

    African Journals Online (AJOL)

    Hybrid system power generation'wind-photovoltaic' connected to the ... from Hybrid System, power delivered to or from grid and phase voltage of the inverter leg. ... Renewable Energy, Electrical Network 220 kV, Hybrid System, Solar, MPPT.

  20. Robust Adaptive Reactive Power Control for Doubly Fed Induction Generator

    Directory of Open Access Journals (Sweden)

    Huabin Wen

    2014-01-01

    Full Text Available The problem of reactive power control for mains-side inverter (MSI in doubly fed induction generator (DFIG is studied in this paper. To accommodate the modelling nonlinearities and inherent uncertainties, a novel robust adaptive control algorithm for MSI is proposed by utilizing Lyapunov theory that ensures asymptotic stability of the system under unpredictable external disturbances and significant parametric uncertainties. The distinguishing benefit of the aforementioned scheme consists in its capabilities to maintain satisfactory performance under varying operation conditions without the need for manually redesigning or reprogramming the control gains in contrast to the commonly used PI/PID control. Simulations are also built to confirm the correctness and benefits of the control scheme.

  1. Embedded generation connection incentives for distribution network operators

    Energy Technology Data Exchange (ETDEWEB)

    Williams, P.; Andrews, S.

    2002-07-01

    This is the final report with respect to work commissioned by the Department of Trade and Industry (DTI) as part of the New and Renewable Energy Programme into incentives for distribution network operators (DNOs) for the connection of embedded generation. This report, which incorporates the contents of the interim report submitted in February 2002, considers the implications of changes in the structure and regulation in the UK electricity industry on the successful technical and commercial integrated of embedded generation into distribution networks. The report examines: the obligations of public electricity suppliers (PESs); current DNO practices regarding the connection of embedded generation; the changes introduced by the Utilities Act 2000, including the impact of new obligations placed on DNOs on the connection of embedded generation and the requirements of the new Electricity Distribution Standard Licence conditions; and problems and prospects for DNO incentives.

  2. Structural Design Optimization of Doubly-Fed Induction Generators Using GeneratorSE

    Energy Technology Data Exchange (ETDEWEB)

    Sethuraman, Latha [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Fingersh, Lee J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Dykes, Katherine L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Arthurs, Claire [Georgia Institute of Technology

    2017-11-13

    A wind turbine with a larger rotor swept area can generate more electricity, however, this increases costs disproportionately for manufacturing, transportation, and installation. This poster presents analytical models for optimizing doubly-fed induction generators (DFIGs), with the objective of reducing the costs and mass of wind turbine drivetrains. The structural design for the induction machine includes models for the casing, stator, rotor, and high-speed shaft developed within the DFIG module in the National Renewable Energy Laboratory's wind turbine sizing tool, GeneratorSE. The mechanical integrity of the machine is verified by examining stresses, structural deflections, and modal properties. The optimization results are then validated using finite element analysis (FEA). The results suggest that our analytical model correlates with the FEA in some areas, such as radial deflection, differing by less than 20 percent. But the analytical model requires further development for axial deflections, torsional deflections, and stress calculations.

  3. Selecting tense, aspect, and connecting words in language generation

    Energy Technology Data Exchange (ETDEWEB)

    Gaasterland, T. [Argonne National Lab., IL (United States). Mathematics and Computer Science Div.; Dorr, B. [Univ. of Maryland, College Park, MD (United States). Dept. of Computer Science

    1995-12-31

    Generating language that reflects the temporal organization of represented knowledge requires a language generation model that integrates contemporary theories of tense and aspect, temporal representations, and methods to plan text. This paper presents a model that produces complex sentences that reflect temporal relations present in underlying temporal concepts. The main result of this work is the successful application of constrained linguistic theories of tense and aspect to a generator which produces meaningful event combinations and selects appropriate connecting words that relate them.

  4. Performance analysis of a simple shunt and series compensated six-phase self-excited induction generator for stand-alone renewable energy generation

    International Nuclear Information System (INIS)

    Singh, G.K.; Kumar, A. Senthil; Saini, R.P.

    2011-01-01

    This paper describes a new generalized and efficient model for performance analysis of a six-phase self-excited induction generator (SPSEIG) with three capacitor excitation topologies; simple shunt, short shunt and long shunt. Mathematical model of SPSEIG is formulated using nodal admittance method based on graph theory. Attention is focused on the influence of the different capacitor connections on the generator overload and output power capabilities. The generator voltage with simple shunt excitation connection collapses when it is overloaded while with either the short shunt or long shunt excitation connection; generator is able to sustain the load at a lower operating voltage and larger load current. The matrix equation developed by nodal admittance method is solved by Genetic Algorithm (GA) technique to predetermine the steady-state performance of SPSEIG. The experimental and theoretical results are found to be in good agreement.

  5. Grid-connected inverter for wind power generation system

    Institute of Scientific and Technical Information of China (English)

    YANG Yong; RUAN Yi; SHEN Huan-qing; TANG Yan-yan; YANG Ying

    2009-01-01

    In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on PI-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.

  6. Technology of VAr Compensators for Induction Generator Applications in Wind Energy Conversion Systems

    Directory of Open Access Journals (Sweden)

    A. F. Zobaa

    2006-09-01

    Full Text Available Many of today utility interconnected wind farms use induction generator (IG to convert the captured wind mechanical power into electricity. Induction generator has some advantages over the synchronous generator (SG. The main advantages are its robustness and its capability to be synchronized directly to the grid. The main disadvantage, however, is its dependency on the grid for supplying its own reactive power ‘VAr’. Whether fixed or adjustable VAr systems are connected across its terminal, IG must operate at unity power factor at the rated loading while the wind power varies. With supervised control and appropriate coordination, VAr can be used to the benefits of both the wind farm developer and the hosting utility. The incorporation of today adjustable reactive power compensators such as the Static VAr Compensation (SVC and Static Synchronous Compensator (STATCOM with IG are vital ingredient toward a successful penetration of wind energy in today distribution grid to ensure voltage stability during the steady state and transient periods.

  7. Control of variable speed wind turbines with doubly-fed induction generators

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, A.D.; Soerensen, P.; Iov, F.; Blaabjerg, F.

    2005-07-01

    The paper presents an overall control method for variable speed pitch controlled wind turbines with doubly-fed induction generators (DFIG). Emphasis is on control strategies and algorithms applied at each hierarchical control level of the wind turbine. The objectives of the control system are: 1) to control the power drawn from the wind turbine in order to track the wind turbine maximum power operation point, 2) to limit the power in case of large wind speeds, and 3) to control the reactive power interchanged between the wind turbine generator and the grid. The present control method is designed for normal continuous operations. The strongest feature of the implemented control method is that it allows the turbine to operate with the optimum power efficiency over a wide range of wind speeds. The model of the variable speed, variable pitch wind turbine with doubly-fed induction generator is implemented in the dynamic power system simulation tool DlgSILENT PowerFactory which allows investigation of the dynamic performance of grid-connected wind turbines within realistic electrical grid models. Simulation results are presented and analysed in different normal operating conditions. (author)

  8. Transient performances analysis of wind turbine system with induction generator including flux saturation and skin effect

    DEFF Research Database (Denmark)

    Li, H.; Zhao, B.; Han, L.

    2010-01-01

    In order to analyze correctly the effect of different models for induction generators on the transient performances of large wind power generation, Wind turbine driven squirrel cage induction generator (SCIG) models taking into account both main and leakage flux saturation and skin effect were...

  9. Dynamic participation of doubly fed induction generator in automatic generation control

    Energy Technology Data Exchange (ETDEWEB)

    Bhatt, Praghnesh [Department of Electrical Engineering, Charotar Institute of Technology, Changa, Gujarat-388421 (India); Roy, Ranjit [Department of Electrical Engineering, S.V. National Institute of Technology, Surat, Gujarat-395007 (India); Ghoshal, S.P. [Department of Electrical Engineering, National Institute of Technology, Durgapur, West Bengal-713209 (India)

    2011-04-15

    Increasing levels of wind generation have resulted in an urgent need for the assessment of their impact on frequency control of power systems. The displacement of conventional generation with wind generation will result in erosion of system frequency. The paper analyzed the dynamic participation of doubly fed induction generator (DFIG) to system frequency responses of two-area interconnected power system having variety of conventional generating units. Frequency control support function responding proportionally to frequency deviation is proposed to take out the kinetic energy of turbine blades in order to improve the frequency response of the system. Impacts of different wind penetrations in the system and varying active power support from wind farm on frequency control have been investigated. Integral gains of AGC loop are optimized through craziness-based particle swarm optimization (CRPSO) in order to have optimal transient responses of area frequencies, tie-line power deviation and DFIG parameters. (author)

  10. Observer-based estimation of stator-winding faults in delta-connected induction motors

    DEFF Research Database (Denmark)

    Skovemose Kallesøe, Carsten; Izadi-Zamanabadi, Roozbeh; Vadstrup, Pierre

    2007-01-01

    This paper addresses the subject of interturn short circuit estimation in the stator of a delta-connected induction motor. In this paper, an adaptive observer scheme is proposed. The proposed observer is capable of simultaneously estimating the speed of the motor, the amount turns involved...... in the short circuit, and an expression of the current in the short circuit. Moreover, the currents are made available even though a fault has occurred in the motor. To be able to develop this observer, a model that is particularly suitable for the chosen observer design, is also derived. The effeciency...... of the proposed observer is demonstrated by tests performed on a test setup with a customized designed induction motor. With this motor it is possible to simulate interturn short-circuit faults....

  11. Transfer function modeling of parallel connected two three-phase induction motor implementation using LabView platform

    DEFF Research Database (Denmark)

    Gunabalan, R.; Sanjeevikumar, P.; Blaabjerg, Frede

    2015-01-01

    This paper presents the transfer function modeling and stability analysis of two induction motors of same ratings and parameters connected in parallel. The induction motors are controlled by a single inverter and the entire drive system is modeled using transfer function in LabView. Further...

  12. Grid-Connected Inverter for Distributed Generation in Microgrid

    DEFF Research Database (Denmark)

    Naderipour, Amirreza; Miveh, Mohammad Reza; Guerrero, Josep M.

    for power generation. DGS units can operate in parallel to the main grid or in a Microgrid (MG) mode. An MG is a discrete energy system consisting of DGSs and loads capable of operating in parallel with, or independently from, the main grid. Meanwhile, Grid-Connected Inverters (GCIs) are typically used...

  13. Inductive thermal plasma generation applied for the materials coating

    International Nuclear Information System (INIS)

    Pacheco, J.; Pena, R.; Cota, G.; Segovia, A.; Cruz, A.

    1996-01-01

    The coatings by thermal plasma are carried out introducing particles into a plasma system where they are accelerated and melted (total or partially) before striking the substrate to which they adhere and are suddenly cooled down. The nature of consolidation and solidification of the particles allows to have control upon the microstructure of the deposit. This technique is able to deposit any kind of material that is suitable to be merged (metal, alloy, ceramic, glass) upon any type of substrate (metal, graphite, ceramic, wood) with an adjustable thickness ranging from a few microns up to several millimeters. The applications are particularly focused to the coating of materials in order to improve their properties of resistance to corrosion, thermal and mechanical efforts as well as to preserve the properties of the so formed compound. In this work the electromagnetic induction phenomenon in an ionized medium by means of electric conductivity, is described. Emphasis is made on the devices and control systems employed in order to generate the thermal plasma and in carrying out the coatings of surfaces by the projection of particles based on plasma

  14. Distributed generation connected to the local network - a guide

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This guide provides advice to the developers and operators of small distributed generation plant (including microgenerators) in the UK about the practical issues associated with connecting their plant and trading their output. Particular attention is given to sales revenues and how to access these revenue streams, including the mechanisms for purchasing Renewable Obligation Certificates (ROCs). The guide clarifies key terms, explains the wholesale trading system and provides an overview of sales opportunities (including ROCs and Levy Exemption Certificates (LECs)). Requirements on small distributed generation (including licensing, claiming class exemptions and metering) are described and the commercial aspects of connection (including the recent reduction in the barriers to connection) examined. Microgeneration (ie generators below 10 kW) issues are covered in their own chapter. The six appendices contain: background information about the industry; a list of purchasers of electricity from small distributed generators; descriptions of the generation, transmission and supply industries; information about industry standards and their governance; the role of government departments and institutions; and a glossary and other links.

  15. Transient Model Validation of Fixed-Speed Induction Generator Using Wind Farm Measurements

    DEFF Research Database (Denmark)

    Rogdakis, Georgios; Garcia-Valle, Rodrigo; Arana Aristi, Iván

    2012-01-01

    In this paper, an electromagnetic transient model for fixed-speed wind turbines equipped with induction generators is developed and implemented in PSCAD/EMTDC. The model is comprised by: an induction generator, aerodynamic rotor, and a two-mass representation of the shaft system. Model validation...

  16. Grid-Connected Distributed Generation: Compensation Mechanism Basics

    Energy Technology Data Exchange (ETDEWEB)

    Aznar, Alexandra Y [National Renewable Energy Laboratory (NREL), Golden, CO (United States); ; ; ; Zinaman, Owen R [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-10-02

    This short report defines compensation mechanisms for grid-connected, behind-the-meter distributed generation (DG) systems as instruments that comprise three core elements: (1) metering and billing arrangements, (2) sell rate design, and (3) retail rate design. This report describes metering and billing arrangements, with some limited discussion of sell rate design. We detail the three possible arrangements for metering and billing of DG: net energy metering (NEM); buy all, sell all; and net billing.

  17. State reference design and saturated control of doubly-fed induction generators under voltage dips

    Science.gov (United States)

    Tilli, Andrea; Conficoni, Christian; Hashemi, Ahmad

    2017-04-01

    In this paper, the stator/rotor currents control problem of doubly-fed induction generator under faulty line voltage is carried out. Common grid faults cause a steep decline in the line voltage profile, commonly denoted as voltage dip. This point is critical for such kind of machines, having their stator windings directly connected to the grid. In this respect, solid methodological nonlinear control theory arguments are exploited and applied to design a novel controller, whose main goal is to improve the system behaviour during voltage dips, endowing it with low voltage ride through capability, a fundamental feature required by modern Grid Codes. The proposed solution exploits both feedforward and feedback actions. The feedforward part relies on suitable reference trajectories for the system internal dynamics, which are designed to prevent large oscillations in the rotor currents and command voltages, excited by line perturbations. The feedback part uses state measurements and is designed according to Linear Matrix Inequalities (LMI) based saturated control techniques to further reduce oscillations, while explicitly accounting for the system constraints. Numerical simulations verify the benefits of the internal dynamics trajectory planning, and the saturated state feedback action, in crucially improving the Doubly-Fed Induction Machine response under severe grid faults.

  18. Transformer supply of inductive and resistive loads of a magnetocumulative generator

    International Nuclear Information System (INIS)

    Kravchenko, A.S.; Lyudaev, R.Z.; Pavlovskij, A.I.; Plyashkevich, L.N.; Shuvalov, A.M.

    1981-01-01

    Variants of transformer energy outlet from magnetocumulative generator (MCG) to inductive and resistive loads are considered. For engineer calculations of transformer MCG electrotechnical model supplemented with a known from the experiment fact of existence of optimum by energy generator finite inductivity turns to be useful. The possibility of current front shortening in the load using a transformer idle running and current pulse shaping at current damping upon the finishing of generator performance is considered [ru

  19. A Condensed Introduction to the Doubly Fed Induction Generator Wind Energy Conversion Systems

    Directory of Open Access Journals (Sweden)

    Julius Mwaniki

    2017-01-01

    Full Text Available The increase in wind power penetration, at 456 GW as of June 2016, has resulted in more stringent grid codes which specify that the wind energy conversion systems (WECS must remain connected to the system during and after a grid fault and, furthermore, must offer grid support by providing reactive currents. The doubly fed induction generator (DFIG WECS is a well-proven technology, having been in use in wind power generation for many years and having a large world market share due to its many merits. Newer technologies such as the direct drive gearless permanent magnet synchronous generator have come up to challenge its market share, but the large number of installed machines ensures that it remains of interest in the wind industry. This paper presents a concise introduction of the DFIG WECS covering its construction, operation, merits, demerits, modelling, control types, levels and strategies, faults and their proposed solutions, and, finally, simulation. Qualities for the optimal control strategy are then proposed. The paper is intended to cover major issues related to the DFIG WECS that are a must for an overview of the system and hence serve as an introduction especially for new entrants into this area of study.

  20. Analysis of the Dynamic Performance of Self-Excited Induction Generators Employed in Renewable Energy Generation

    Directory of Open Access Journals (Sweden)

    Mohamed E. A. Farrag

    2014-01-01

    Full Text Available Incentives, such as the Feed-in-tariff are expected to lead to continuous increase in the deployment of Small Scale Embedded Generation (SSEG in the distribution network. Self-Excited Induction Generators (SEIG represent a significant segment of potential SSEG. The quality of SEIG output voltage magnitude and frequency is investigated in this paper to support the SEIG operation for different network operating conditions. The dynamic behaviour of the SEIG resulting from disconnection, reconnection from/to the grid and potential operation in islanding mode is studied in detail. The local load and reactive power supply are the key factors that determine the SEIG performance, as they have significant influence on the voltage and frequency change after disconnection from the grid. Hence, the aim of this work is to identify the optimum combination of the reactive power supply (essential for self excitation of the SEIG and the active load (essential for balancing power generation and demand. This is required in order to support the SEIG operation after disconnection from the grid, during islanding and reconnection to the grid. The results show that the generator voltage and speed (frequency can be controlled and maintained within the statuary limits. This will enable safe disconnection and reconnection of the SEIG from/to the grid and makes it easier to operate in islanding mode.

  1. Facilitate generation connections on Orkney by automatic distribution network management

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    This report summarises the results of a study assessing the capability and limitations of the Orkney Network under a variety of conditions of demand, generation connections, network configuration, and reactive compensation). A conceptual active management scheme (AMS) suitable for the conditions on Orkney is developed and evaluated. Details are given of a proposed framework for the design and evaluation of future active management schemes, logic control sequences for managed generation units, and a proposed evaluation method for the active management scheme. Implications of introducing the proposed AMS are examined, and the commercial aspects of an AMS and system security are considered. The existing Orkney network is described; and an overview of the SHEPDL (Scottish Hydro Electric Power Distribution Ltd.) SCADA system is presented with a discussion of AMS identification, selection, and development.

  2. Simulation of Photovoltaic generator Connected To a Grid

    Directory of Open Access Journals (Sweden)

    F. Slama

    2014-03-01

    Full Text Available This paper presents the mathematical and the total Matlab-simulink model of the various components, of the photovoltaic power station connected to a network, (PSCN, namely the model of the photovoltaic generator. It is a comprehensive behavioural study which performed according to varying conditions of solar insulation and temperature. The photovoltaic generator and the inverter of single-phase current are modeled. The former by using a mathematical model that gives the values of maximum power according to the variation of the weather conditions, and the latter by a source of voltage controlled by voltage in order to inject a sinusoidal current and to estimate or predict the energy injected monthly or annually into the network.

  3. Effect of wind generation system types on Micro-Grid (MG) fault performance during both standalone and grid connected modes

    International Nuclear Information System (INIS)

    Kamel, Rashad M.

    2014-01-01

    Highlights: • This paper evaluated the effects of different wind system types on fault performance of Micro-Grid. • Both standalone and grid connected modes are considered. • The MG earthing system configuration is taken in consideration. - Abstract: Recently, there are three wind generation (WG) system types. The first type is called Fixed Speed Wind Generation (FSWG) system, which employs squirrel cage induction generators. Double Fed Induction Generator (DFIG) is utilized in the second type. The third type is called Full Converter Wind Generation (FCWG) system, which is interfaced with Micro-Grid (MG) through a back to back converter. During fault occurrence, each WG has its performance and characteristics which are determined by the generator physical characteristics and the MG earthing system configuration. For some WG types, the fault current depends also on the control algorithm of the power converter. The main target of this paper is to investigate and estimate how the fault performance of MG during both standalone and grid-connected modes is influenced by the type of WG. It is found during standalone mode that the type of the employed WG has a dominant impact on the MG performance under fault disturbance. On the contrary, the type of the employed WG has a negligible effect on the MG fault performance during grid-connected mode. This is because the main grid contributes most of the fault current. Effects of earthing system type on MG performance are highlighted

  4. Overall control strategy of variable speed doubly-fed induction generator wind turbine

    DEFF Research Database (Denmark)

    Hansen, A.D.; Iov, F.; Sørensen, Poul Ejnar

    2004-01-01

    The variable speed doubly-fed induction generator wind turbine is today the most widely used concept. The paper presents an overall control system of the variable speed DFIG wind turbine, with focus on the control strategies and algorithms applied at each hierarchical control level of the wind tu......-fed induction generator is implemented in the dynamic power system simulation tool DIgSILENT. Simulation results are performed and analyzed in different normal operating conditions....

  5. A Concise Presentation of Doubly Fed Induction Generator Wind Energy Conversion Systems Challenges and Solutions

    Directory of Open Access Journals (Sweden)

    Julius Mwaniki

    2017-01-01

    Full Text Available There is increased worldwide wind power generation, a large percentage of which is grid connected. The doubly fed induction generator (DFIG wind energy conversion system (WECS has many merits and, as a result, large numbers have been installed to date. The DFIG WECS operation, under both steady state and fault conditions, is of great interest since it impacts on grid performance. This review paper presents a condensed look at the various applied solutions to the challenges of the DFIG WECS including maximum power point tracking, common mode voltages, subsynchronous resonance, losses, modulation, power quality, and faults both internal and from the grid. It also looks at approaches used to meet the increasingly stringent grid codes requirements for the DFIG WECS to not only ride through faults but also provide voltage support. These are aspects of the DFIG WECS that are critical for system operators and prospective investors and can also serve as an introduction for new entrants into this area of study.

  6. Current pulse generator of an induction accelerator electromagnet

    International Nuclear Information System (INIS)

    Baginskij, B.A.; Makarevich, V.N.; Shtejn, M.M.

    1987-01-01

    Thyristor generator forming in betatron electromagnet coil sinusoidal and quasisinusoidal current unipolar pulses, the field being deforced at the beginning of acceleration cycle, and with the pulse flat top in the cycle end, is described. The current amplitude is controlled by pulse-phase method. The current pulse time shift permitted to decrease the loss rate in the accumulating capacitor. The generator is used in systems with 1-10 ms pulse duration, electromagnet magnetic field maximal energy - 45-450 J, the voltage amplitude in the coil 960-1500 V and amplitude of the current passing the coil 100-500 A, the repetition frequency being 50-200 Hz. In particular, the generator is used to supply betatrons designed for defectoscopy in nonstationary conditions, the accelerated electron energy being 4, 6, 8 and 15 MeV

  7. Low-induction pulse current generator with a volume bus arrangement

    International Nuclear Information System (INIS)

    Bocharov, Yu.N.; Krivosheev, S.I.; Lapin, N.G.; Shneerson, G.A.

    1993-01-01

    Pulse current generator (PC6) with 38 kj stored energy designed for up to 50 kV charging voltage used to obtain magnetic fields within megagauss range, is described. Space (volume) bus arrangement of its modules is used to reduce eigen inductance of PC6. Current is commutated by solid-body spark gaps. Under 3uH inductive load PC6 provides for formation of up to 2.25 MA current pulse with 3.3x10 12 A/s pulse rise time. Technique to determine low inductances as applied to PC6 elements is described. The described PC6 is used for experiments on generation of super-strong pulse magnetic fields in single-loop solenoid with volume occupied by magnetic field, 5-7 mm. Magnetic field with up to 350 T induction amplitude is obtained in these experiments

  8. Complementary Power Control for Doubly Fed Induction Generator-Based Tidal Stream Turbine Generation Plants

    Directory of Open Access Journals (Sweden)

    Khaoula Ghefiri

    2017-06-01

    Full Text Available The latest forecasts on the upcoming effects of climate change are leading to a change in the worldwide power production model, with governments promoting clean and renewable energies, as is the case of tidal energy. Nevertheless, it is still necessary to improve the efficiency and lower the costs of the involved processes in order to achieve a Levelized Cost of Energy (LCoE that allows these devices to be commercially competitive. In this context, this paper presents a novel complementary control strategy aimed to maximize the output power of a Tidal Stream Turbine (TST composed of a hydrodynamic turbine, a Doubly-Fed Induction Generator (DFIG and a back-to-back power converter. In particular, a global control scheme that supervises the switching between the two operation modes is developed and implemented. When the tidal speed is low enough, the plant operates in variable speed mode, where the system is regulated so that the turbo-generator module works in maximum power extraction mode for each given tidal velocity. For this purpose, the proposed back-to-back converter makes use of the field-oriented control in both the rotor side and grid side converters, so that a maximum power point tracking-based rotational speed control is applied in the Rotor Side Converter (RSC to obtain the maximum power output. Analogously, when the system operates in power limitation mode, a pitch angle control is used to limit the power captured in the case of high tidal speeds. Both control schemes are then coordinated within a novel complementary control strategy. The results show an excellent performance of the system, affording maximum power extraction regardless of the tidal stream input.

  9. DC Link Current Estimation in Wind-Double Feed Induction Generator Power Conditioning System

    Directory of Open Access Journals (Sweden)

    MARIAN GAICEANU

    2010-12-01

    Full Text Available In this paper the implementation of the DC link current estimator in power conditioning system of the variable speed wind turbine is shown. The wind turbine is connected to double feed induction generator (DFIG. The variable electrical energy parameters delivered by DFIG are fitted with the electrical grid parameters through back-to-back power converter. The bidirectional AC-AC power converter covers a wide speed range from subsynchronous to supersynchronous speeds. The modern control of back-to-back power converter involves power balance concept, therefore its load power should be known in any instant. By using the power balance control, the DC link voltage variation at the load changes can be reduced. In this paper the load power is estimated from the dc link, indirectly, through a second order DC link current estimator. The load current estimator is based on the DC link voltage and on the dc link input current of the rotor side converter. This method presents certain advantages instead of using measured method, which requires a low pass filter: no time delay, the feedforward current component has no ripple, no additional hardware, and more fast control response. Through the numerical simulation the performances of the proposed DC link output current estimator scheme are demonstrated.

  10. Transient Response Improvement of Microgrids Exploiting the Inertia of a Doubly-Fed Induction Generator (DFIG

    Directory of Open Access Journals (Sweden)

    Christina N. Papadimitriou

    2010-06-01

    Full Text Available Storage devices are introduced in microgrids in order to secure their power quality, power regularity and offer ancillary services in a transient period. In the transition period of a low voltage microgrid, from the connected mode of operation to the islanded mode of operation, the power unbalance can be partly covered by the inertia energy of the existing power sources. This paper proposes fuzzy local controllers exploiting the inertia of a Wind Turbine (WT with a Doubly Fed Induction Generator (DFIG, if such a machine exists in the microgrid, in order to decrease the necessary storage devices and the drawbacks that arise. The proposed controllers are based in fuzzy logic due to the non linear and stochastic behavior of the system. Two cases are studied and compared during the transient period where the microgrid architecture and the DFIG controller differ. In the first case, the understudy microgrid includes a hybrid fuel cell system (FCS-battery system and a WT with a DFIGURE. The DFIG local controller in this case is also based in fuzzy logic and follows the classical optimum power absorption scenario for the WT. The transition of the microgrid from the connected mode of operation to the islanded mode is evaluated and, especially, the battery contribution is estimated. In the second case, the battery is eliminated. The fuzzy controller of the DFIG during the transition provides primary frequency control and local bus voltage support exploiting the WT inertia. The response of the system is estimated in both cases using MATLAB/Simulink software package.

  11. Capacitor Current Feedback-Based Active Resonance Damping Strategies for Digitally-Controlled Inductive-Capacitive-Inductive-Filtered Grid-Connected Inverters

    DEFF Research Database (Denmark)

    Lorzadeh, Iman; Askarian Abyaneh, Hossein; Savaghebi, Mehdi

    2016-01-01

    Inductive-capacitive-inductive (LCL)-type line filters are widely used in grid-connected voltage source inverters (VSIs), since they can provide substantially improved attenuation of switching harmonics in currents injected into the grid with lower cost, weight and power losses than their L......-type counterparts. However, the inclusion of third order LCL network complicates the current control design regarding the system stability issues because of an inherent resonance peak which appears in the open-loop transfer function of the inverter control system near the control stability boundary. To avoid...... passive (resistive) resonance damping solutions, due to their additional power losses, active damping (AD) techniques are often applied with proper control algorithms in order to damp the LCL filter resonance and stabilize the system. Among these techniques, the capacitor current feedback (CCF) AD has...

  12. Design of motor induction 3-Phase from waste industry to generator for microhydro at isolated village

    Science.gov (United States)

    Rimbawati; Azis Hutasuhut, Abdul; Irsan Pasaribu, Faisal; Cholish; Muharnif

    2017-09-01

    There is an electric machine that can operate as a generator either single-phase or three-phase in almost every household and industry today. This electric engine cannot be labeled as a generator but can be functioned as a generator. The machine that is mentioned is “squirrel cage motors” or it is well-known as induction motor that can be found in water pumps, washing machines, fans, blowers and other industrial machines. The induction motor can be functioned as a generator when the rotational speed of the rotor is made larger than the speed of the rotary field. In this regard, this study aims to modify the remains of 3-phase induction motor to be a permanent generator. Data of research based conducted on the river flow of Rumah Sumbul Village, STM Hulu district of Deli Serdang. The method of this research is by changing rotor and stator winding on a 3 phase induction motor, so it can produce a generator with rotation speed of 500 rpm. Based on the research, it can be concluded that the output voltage generator has occurred a voltage drop 10% between before and after loading for Star circuit and 2% for Delta circuit.

  13. Control System for Producing Electricity with Dual Stator Winding Cage-Rotor Induction Generator

    Directory of Open Access Journals (Sweden)

    Lucian Nicolae Tutelea

    2014-09-01

    Full Text Available This paper will present the key design equations and control design model of the Dual Stator Winding Cage-Rotor Induction Generator (DSWIG to achieve wide-speed-range operation with reduced capacity of the static power controller for low power wind or hydro applications. The proposed induction generator consists of a standard squirrel-cage rotor and a stator with two separate windings wound for a similar number of poles. Moreover, the system control strategy using the stator flux orientation is consequently proposed. The aim of the paper is to emphasize that the low speed induction generators with power electronic converters represent a realistic and useful solution for direct drive power applications.

  14. INVESTIGATION ON ESTABLISHED OPERATIONAL MODES OF FREQUENCY-CONTROLLED INDUCTION GENERATOR OF WIND POWER PLANTS

    Directory of Open Access Journals (Sweden)

    R. I. Mustafayev

    2014-01-01

    Full Text Available The paper proposes an analytical expression for calculating a manipulated variable of stator voltage in a frequency-controlled induction generator with a cage rotor of a wind power plant while regulating a constant value of the absolute slip of the generator. Comparison of the calculated results by the proposed expression and full differential equations of the generator (an equation of state at steady state has confirmed a high accuracy of the analytical expression.

  15. Stabilization of Voltage Parameters of Induction Generator Excited by a Voltage Inverter

    Directory of Open Access Journals (Sweden)

    Padalko D.A.

    2017-12-01

    Full Text Available The article reveals the operational aspects of induction generator. Methods for stabilization of induction generator (IG parameters under inverter excitation are investigated. The study was carried out using mathematical description and simulation modeling in MATLAB Simulink. The paper provides analysis of causes of generated voltage amplitude and frequency displacement when the loading condition and the rate vary. Due to the parametric resonance nature of IG self-excitation, the author introduces the expression that allows estimating the capacitor capacitance required to maintain the generation process, depending on the rotor speed of electric machine, load nature and rate. Based on the studies, it was proved that it is possible to stabilize the IG voltage parameters by maintaining the magnetizing circuit inductance Lm at the constant level., and realizing a control law close to U/f = const. The study proves that using the inverter together with the voltage regulator allows ensuring the quality of electricity corresponding to modern standards. The necessity of problem solving of the required quality of the voltage by the harmonic component for the exciter - inverter with PWM is shown. The prospects of the power generation system based on induction machine (IM with a semiconductor frequency converter, which serves as an adjustable supplier of capacitive current for IM for autonomous objects, are substantiated. The use of semiconductor frequency converters makes it possible to provide high stability of the output voltage parameters and good speed of the mechatronic generation system with an asynchronous machine.

  16. Symbolic Solution Approach to Wind Turbine based on Doubly Fed Induction Generator Model

    DEFF Research Database (Denmark)

    Cañas–Carretón, M.; Gómez–Lázaro, E.; Martín–Martínez, S.

    2015-01-01

    –order induction generator is selected to model the electric machine, being this approach suitable to estimate the DFIG performance under transient conditions. The corresponding non–linear integro-differential equation system has been reduced to a linear state-space system by using an ad-hoc local linearization......This paper describes an alternative approach based on symbolic computations to simulate wind turbines equipped with Doubly–Fed Induction Generator (DFIG). The actuator disk theory is used to represent the aerodynamic part, and the one-mass model simulates the mechanical part. The 5th...

  17. Sliding Mode Control of a Variable- Speed Wind Energy Conversion System Using a Squirrel Cage Induction Generator

    Directory of Open Access Journals (Sweden)

    Mohamed Zribi

    2017-05-01

    Full Text Available This paper deals with the control of a variable-speed wind energy conversion (WEC system using a squirrel cage induction generator (SCIG connected to the grid through a back-to-back three phase (AC-DC-AC power converter. The sliding mode control technique is used to control the WEC system. The objective of the controllers is to force the states of the system to track their desired states. One controller is used to regulate the generator speed and the flux so that maximum power is extracted from the wind. Another controller is used to control the grid side converter, which controls the DC bus voltage and the active and reactive powers injected into the grid. The performance of the controlled wind energy conversion system is verified through MATLAB simulations, which show that the controlled system performs well.

  18. Analog Amplitude Modulation of a High Voltage, Solid State Inductive Adder, Pulse Generator Using MOSFETS

    International Nuclear Information System (INIS)

    Gower, E J; Sullivan, J S

    2002-01-01

    High voltage, solid state, inductive adder, pulse generators have found increasing application as fast kicker pulse modulators for charged particle beams. The solid state, inductive adder, pulse generator is similar in operation to the linear induction accelerator. The main difference is that the solid state, adder couples energy by transformer action from multiple primaries to a voltage summing stalk, instead of an electron beam. Ideally, the inductive adder produces a rectangular voltage pulse at the load. In reality, there is usually some voltage variation at the load due to droop on primary circuit storage capacitors, or, temporal variations in the load impedance. Power MOSFET circuits have been developed to provide analog modulation of the output voltage amplitude of a solid state, inductive adder, pulse generator. The modulation is achieved by including MOSFET based, variable subtraction circuits in the multiple primary stack. The subtraction circuits can be used to compensate for voltage droop, or, to tailor the output pulse amplitude to provide a desired effect in the load. Power MOSFET subtraction circuits have been developed to modulate short, temporal (60-400 ns), voltage and current pulses. MOSFET devices have been tested up to 20 amps and 800 Volts with a band pass of 50 MHz. An analog modulation cell has been tested in a five cell high, voltage adder stack

  19. Capacitive VAr requirements for wind driven self-excited induction generators

    International Nuclear Information System (INIS)

    Singaravelu, S.; Velusami, S.

    2007-01-01

    This paper presents the capacitive VAr requirements of a three phase pole changing self-excited induction generator and a single phase self-excited induction generator, used as isolated power sources by a constant speed or a variable speed prime mover, to obtain the desired voltage regulation at various values of load and speed. Different performance criteria such as constant terminal voltage or constant air gap flux have been considered. The developed mathematical model using nodal analysis based on graph theory is quite general in nature and can be used for any combination of the unknown variables such as magnetizing reactance (X M ) and frequency (F) or capacitive reactance (X C ) and frequency (F) or capacitive reactance (X C ) and speed (υ). The proposed model completely avoids the tedious and erroneous manual work of segregating the real and imaginary components of the complex impedance of the machine for deriving the specific model for each operating modes. Moreover, any element, like the core loss component, can be included or excluded from the model if required. Next, to obtain the capacitive VAr requirements of a three phase pole changing self-excited induction generator and a single phase self-excited induction generator, a fuzzy logic approach is used for the first time to find the unknown variables using the above model. The results are presented in a normalized form so that they are valid for a wide range of machines and would be useful for the design of voltage regulators for such generators

  20. Capacitor Current Feedback-Based Active Resonance Damping Strategies for Digitally-Controlled Inductive-Capacitive-Inductive-Filtered Grid-Connected Inverters

    Directory of Open Access Journals (Sweden)

    Iman Lorzadeh

    2016-08-01

    Full Text Available Inductive-capacitive-inductive (LCL-type line filters are widely used in grid-connected voltage source inverters (VSIs, since they can provide substantially improved attenuation of switching harmonics in currents injected into the grid with lower cost, weight and power losses than their L-type counterparts. However, the inclusion of third order LCL network complicates the current control design regarding the system stability issues because of an inherent resonance peak which appears in the open-loop transfer function of the inverter control system near the control stability boundary. To avoid passive (resistive resonance damping solutions, due to their additional power losses, active damping (AD techniques are often applied with proper control algorithms in order to damp the LCL filter resonance and stabilize the system. Among these techniques, the capacitor current feedback (CCF AD has attracted considerable attention due to its effective damping performance and simple implementation. This paper thus presents a state-of-the-art review of resonance and stability characteristics of CCF-based AD approaches for a digitally-controlled LCL filter-based grid-connected inverter taking into account the effect of computation and pulse width modulation (PWM delays along with a detailed analysis on proper design and implementation.

  1. Analysis of synchronous and induction generators used at hydroelectric power plant

    Science.gov (United States)

    Diniş, C. M.; Popa, G. N.; lagăr, A.

    2017-01-01

    In this paper is presented an analysis of the operating electric generators (synchronous and induction) within a small capacity hydroelectric power plant. Such is treated the problem of monitoring and control hydropower plant using SCADA systems. Have been carried an experimental measurements in small hydropower plant for different levels of water in the lake and various settings of the operating parameters.

  2. Model and performance of current sensor observers for a doubly fed induction generator

    DEFF Research Database (Denmark)

    Li, Hui; Yang, Chao; Hu, Yaogang

    2014-01-01

    . A stator and rotor current observer model, which is based on the state-space models of doubly fed induction generators, is then derived by using the stator and rotor voltage signals as inputs. To demonstrate the effectiveness of the proposed current observer, its dynamic performance is simulated using...

  3. Thermal Behavior of Doubly-Fed Induction Generator Wind Turbine System during Balanced Grid Fault

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede; Lau, Mogens

    2014-01-01

    Ride-through capabilities of the doubly-fed induction generator (DFIG) during grid fault have been studied a lot. However, the thermal performance of the power device during this transient period is seldom investigated. In this paper, the dynamic model for the DFIG and the influence of the rotor...

  4. Rotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid Faults

    DEFF Research Database (Denmark)

    Lima, Francisco K. A.; Luna, Alvaro; Rodriguez, Pedro

    2010-01-01

    This paper presents a new control strategy for the rotor-side converter (RSC) of wind turbines (WTs) based on doubly fed induction generators (DFIG) that intends to improve its low-voltage ride through capability. The main objective of this work is to design an algorithm that would enable the sys...

  5. IQC-based robust stability analysis for LPV control of doubly-fed induction generators

    NARCIS (Netherlands)

    Tien, H. N.; Scherer, C. W.; Scherpen, J. M. A.

    2008-01-01

    Parameters of electrical machines are usually varying with time in a smooth way due to changing operating conditions, such as variations in the machine temperature and/or the magnetic saturation. This paper is concerned with robust stability analysis of controlled Doubly-Fed Induction Generators

  6. High Order Sliding Mode Control of Doubly-fed Induction Generator under Unbalanced Grid Faults

    DEFF Research Database (Denmark)

    Zhu, Rongwu; Chen, Zhe; Wu, Xiaojie

    2013-01-01

    This paper deals with a doubly-fed induction generator-based (DFIG) wind turbine system under grid fault conditions such as: unbalanced grid voltage, three-phase grid fault, using a high order sliding mode control (SMC). A second order sliding mode controller, which is robust with respect...

  7. Hopf bifurcation and eigenvalue sensitivity analysis of doubly fed induction generator wind turbine system

    DEFF Research Database (Denmark)

    Yang, Li Hui; Xu, Zhao; Østergaard, Jacob

    2010-01-01

    This paper first presents the Hopf bifurcation analysis for a vector-controlled doubly fed induction generator (DFIG) which is widely used in wind power conversion systems. Using three-phase back-to-back pulse-width-modulated (PWM) converters, DFIG can keep stator frequency constant under variabl...

  8. Modeling of Self-Excited Isolated Permanent Magnet Induction Generator Using Iterative Numerical Method

    Directory of Open Access Journals (Sweden)

    Mohamed Mostafa R.

    2016-01-01

    Full Text Available Self-Excited Permanent Magnet Induction Generator (PMIG is commonly used in wind energy generation systems. The difficulty of Self-Excited Permanent Magnet Induction Generator (SEPMIG modeling is the circuit parameters of the generator vary at each load conditions due to the a change in the frequency and stator voltage. The paper introduces a new modeling for SEPMIG using Gauss-sidle relaxation method. The SEPMIG characteristics using the proposed method are studied at different load conditions according to the wind speed variation, load impedance changes and different shunted capacitor values. The system modeling is investigated due to the magnetizing current variation, the efficiency variation, the power variation and power factor variation. The proposed modeling system satisfies high degree of simplicity and accuracy.

  9. Reactive power generation in high speed induction machines by continuously occurring space-transients

    Science.gov (United States)

    Laithwaite, E. R.; Kuznetsov, S. B.

    1980-09-01

    A new technique of continuously generating reactive power from the stator of a brushless induction machine is conceived and tested on a 10-kw linear machine and on 35 and 150 rotary cage motors. An auxiliary magnetic wave traveling at rotor speed is artificially created by the space-transient attributable to the asymmetrical stator winding. At least two distinct windings of different pole-pitch must be incorporated. This rotor wave drifts in and out of phase repeatedly with the stator MMF wave proper and the resulting modulation of the airgap flux is used to generate reactive VA apart from that required for magnetization or leakage flux. The VAR generation effect increases with machine size, and leading power factor operation of the entire machine is viable for large industrial motors and power system induction generators.

  10. Voltage and frequency control of wind-powered islanded microgrids based on induction generator and STATCOM

    DEFF Research Database (Denmark)

    Bouzid, Allal; Sicard, Pierre; Guerrero, Josep M.

    2015-01-01

    This paper presents a comprehensive modeling of a three-phase cage induction machine used as a self-excited squirrel-cage induction generator (SEIG), and discusses the regulation of the voltage and frequency of a self-excited SEIG based on the action of the static synchronous Compensator (STATCOM......). The STATCOM with the proposed controller consists of a three-phase voltage-sourced inverter and a DC voltage. The compensator can provide the active and reactive powers and regulate AC system bus voltage and the frequency, but also may enhance the load stability. Moreover, a feed forward control method...

  11. Generation of hydrogen free radicals from water for fuels by electric field induction

    International Nuclear Information System (INIS)

    Nong, Guangzai; Chen, Yiyi; Li, Ming; Zhou, Zongwen

    2015-01-01

    Highlights: • Hydrogen free radicals are generated from water splitting. • Hydrogen fuel is generated from water by electric field induction. • Hydrocarbon fuel is generated from CO_2 and water by electric field induction. - Abstract: Water is the most abundant resource for generating hydrogen fuel. In addition to dissociating H"+ and "−OH ions, certain water molecules dissociate to radicals under an electric field are considered. Therefore, an electric field inducing reactor is constructed and operated to generate hydrogen free radicals in this paper. Hydrogen free radicals begin to be generated under a 1.0 V electric field, and increasing the voltage and temperature increases the number of hydrogen free radicals. The production rate of hydrogen free radicals is 0.245 mmol/(L h) at 5.0 V and room temperature. The generated hydrogen free radicals are converted to polymer fuel and hydrogen fuel at production rates of 0.0093 mmol/(L h) and 0.0038 mmol/(L h) respectively, under 5.0 V and 0.25 mA. The results provide a way to generate hydrogen free radicals, which might be used to generate hydrocarbon fuel in industrial manufacture.

  12. Doubly Fed Induction Generator Wind Turbines with Fuzzy Controller: A Survey

    Directory of Open Access Journals (Sweden)

    J. S. Sathiyanarayanan

    2014-01-01

    Full Text Available Wind energy is one of the extraordinary sources of renewable energy due to its clean character and free availability. With the increasing wind power penetration, the wind farms are directly influencing the power systems. The majority of wind farms are using variable speed wind turbines equipped with doubly fed induction generators (DFIG due to their advantages over other wind turbine generators (WTGs. Therefore, the analysis of wind power dynamics with the DFIG wind turbines has become a very important research issue, especially during transient faults. This paper presents fuzzy logic control of doubly fed induction generator (DFIG wind turbine in a sample power system. Fuzzy logic controller is applied to rotor side converter for active power control and voltage regulation of wind turbine.

  13. Doubly fed induction generator wind turbines with fuzzy controller: a survey.

    Science.gov (United States)

    Sathiyanarayanan, J S; Kumar, A Senthil

    2014-01-01

    Wind energy is one of the extraordinary sources of renewable energy due to its clean character and free availability. With the increasing wind power penetration, the wind farms are directly influencing the power systems. The majority of wind farms are using variable speed wind turbines equipped with doubly fed induction generators (DFIG) due to their advantages over other wind turbine generators (WTGs). Therefore, the analysis of wind power dynamics with the DFIG wind turbines has become a very important research issue, especially during transient faults. This paper presents fuzzy logic control of doubly fed induction generator (DFIG) wind turbine in a sample power system. Fuzzy logic controller is applied to rotor side converter for active power control and voltage regulation of wind turbine.

  14. An approach to the conversion of the power generated by an offshore wind power farm connected into seawave power generator

    Energy Technology Data Exchange (ETDEWEB)

    Franzitta, Vicenzo; Messineo, Antonio; Trapanese, Marco

    2011-07-01

    The development of renewable energy systems has been undergoing for the past decades but sea wave's energy resource has been under-utilized. This under-utilization has several reasons: the energy concentration is low in sea waves, extraction of this energy requires leading edge technologies and conversion of the energy into electrical energy is difficult. This study compares two different methods to connect the sea waves' generator to the network and to the offshore wind power farm. The first method consists in a decentralized approach: each generator is connected to the grid through an AC converter. The second method is a partially centralized approach: a rectifier is connected to each generator, all of the generators are then connected together to a common DC bus and power is then converted in AC to be connected to the grid. This study has shown that the partially centralized approach is more reliable and efficient than the decentralized approach.

  15. State-space modeling of the radio frequency inductively-coupled plasma generator

    International Nuclear Information System (INIS)

    Dewangan, Rakesh Kumar; Punjabi, Sangeeta B; Mangalvedekar, H A; Lande, B K; Joshi, N K; Barve, D N

    2010-01-01

    Computational fluid dynamics models of RF-ICP are useful in understanding the basic transport phenomenon in an ICP torch under a wide variety of operating conditions. However, these models lack the ability to evaluate the effects of the plasma condition on the RF generator. In this paper, simulation of an induction plasma generator has been done using state space modelling by considering inductively coupled plasma as a part of RF network .The time dependent response of the RF-ICP generator circuit to given input excitation has been computed by extracting the circuit's state-space variables and their constraint matrices. MATLAB 7.1 software has been used to solve the state equations. The values of RF coil current, frequency and plasma power has been measured experimentally also at different plate bias voltage. The simulated model is able to predict RF coil current, frequency, plasma power, overall efficiency of the generator. The simulated and measured values are in agreement with each other. This model can prove useful as a design tool for the Induction plasma generator.

  16. Preparing for what might happen: An episodic specificity induction impacts the generation of alternative future events.

    Science.gov (United States)

    Jing, Helen G; Madore, Kevin P; Schacter, Daniel L

    2017-12-01

    A critical adaptive feature of future thinking involves the ability to generate alternative versions of possible future events. However, little is known about the nature of the processes that support this ability. Here we examined whether an episodic specificity induction - brief training in recollecting details of a recent experience that selectively impacts tasks that draw on episodic retrieval - (1) boosts alternative event generation and (2) changes one's initial perceptions of negative future events. In Experiment 1, an episodic specificity induction significantly increased the number of alternative positive outcomes that participants generated to a series of standardized negative events, compared with a control induction not focused on episodic specificity. We also observed larger decreases in the perceived plausibility and negativity of the original events in the specificity condition, where participants generated more alternative outcomes, relative to the control condition. In Experiment 2, we replicated and extended these findings using a series of personalized negative events. Our findings support the idea that episodic memory processes are involved in generating alternative outcomes to anticipated future events, and that boosting the number of alternative outcomes is related to subsequent changes in the perceived plausibility and valence of the original events, which may have implications for psychological well-being. Published by Elsevier B.V.

  17. Connected vehicle insights : fourth generation wireless - vehicle and highway gateways to the cloud.

    Science.gov (United States)

    2011-12-01

    This paper examines next generation wide-area cellular such as fourth generation (4G) will be able to support vehicular applications, and how transportation infrastructure may mesh with wireless networks. : This report is part of the Connected Vehicl...

  18. Improvement of low speed induction generator performances and reducing the power of excitation and voltage control system

    Energy Technology Data Exchange (ETDEWEB)

    Budisan, N. [Politechnica Univ. of Timisoara (Romania); Hentea, T.; Mahil, S. [Purdue Univ. Calumet, Hammond, IN (United States); Madescu, G. [Romanian Academy, Timisoara (Romania)

    1996-12-31

    In this paper we present the results of our investigations concerning the utilization of induction generators at very low speed. It is shown that, by proper design, it is possible to obtain high efficiency and high power factor values. The optimized induction generators require lower reactive power resulting in lower size and price of the excitation control system. 4 refs., 2 figs.

  19. Schemes of high-power pulsed generators with inductive storages on stepped lines

    International Nuclear Information System (INIS)

    Gordeev, V.S.; Bossamykin, V.S.

    1996-01-01

    Some multistage pulse generator designs based on homogeneous transmission lines of equal electrical length T 0 with stepwise impedance changes are described. The energy is initially stored as magnetic field by all the generator stages, while it is also stored by some of them as electrical energy. Upon triggering the switch connecting the high-voltage electrode of charged lines to the grounded generator frame, both the magnetic and electrical energies would concentrate completely at the generator output due to wave effects. Ideally, for any number of stages, the resistive load connected in parallel to the current opening switch is where a square-shaped voltage pulse of 2T 0 width would be generated, whose peak value can be considerably higher than the generator charging voltage. (author). 1 fig., 5 refs

  20. Schemes of high-power pulsed generators with inductive storages on stepped lines

    Energy Technology Data Exchange (ETDEWEB)

    Gordeev, V S; Bossamykin, V S [All-Russian Scientific Research Inst. of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    Some multistage pulse generator designs based on homogeneous transmission lines of equal electrical length T{sub 0} with stepwise impedance changes are described. The energy is initially stored as magnetic field by all the generator stages, while it is also stored by some of them as electrical energy. Upon triggering the switch connecting the high-voltage electrode of charged lines to the grounded generator frame, both the magnetic and electrical energies would concentrate completely at the generator output due to wave effects. Ideally, for any number of stages, the resistive load connected in parallel to the current opening switch is where a square-shaped voltage pulse of 2T{sub 0} width would be generated, whose peak value can be considerably higher than the generator charging voltage. (author). 1 fig., 5 refs.

  1. Connecting the Generations: Memory, Magic, and Harry Potter.

    Science.gov (United States)

    Radigan, Winifred M.

    2001-01-01

    Explains that the author reads the Harry Potter books because of their impact on middle-school-age kids and their appeal to children ages 9 to 15. Explains also that she works in professional development, especially literacy, and that she connects kids and teachers to the books. Admits that she reads the books because "they are wonderful." (SG)

  2. End Effects on the Linear Induction MHD Generator Calculated by Two-Sided Laplace Transform

    Energy Technology Data Exchange (ETDEWEB)

    Engeln, F.; Peschka, W. [Deutsche Versuchsanstalt fuer Luft- und Raumfahrt e.V., Institut fuer Energiewandlung und Elektrische Antriebe, Stuttgart, Federal Republic of Germany (Germany)

    1966-11-15

    In induction MHD systems special problems occur where the flow enters or leaves the magnetic field. These problems are generally described as end effects. Large gradients of the magnetic field are present at the inlet and also at the outlet of an MHD induction engine, these generating electric current systems in the fluid which may spoil the performance characteristics of the generator due to the interaction with the primary field of the engine. The two-dimensional induction MHD generator of finite length, using a polyphase winding system to obtain a travelling magnetic field, is treated as a boundary value problem by two-sided Laplace transform. For simplicity incompressibility is assumed. The two- dimensional boundary value problem of the induction engine is solved for - {infinity} Less-Than-Over-Equal-To x Less-Than-Over-Equal-To {infinity}. x is parallel to the flow direction of the linear MHD generator. In the region 0 Less-Than-Over-Equal-To x Less-Than-Over-Equal-To L the magnetic travelling wave is sinusoidal with a cyclical frequency {omega} and a phase-velocity v{sub s}. At x = 0 the conducting incompressible working fluid enters the field region and leaves it at the point-x = L. Two mathematical methods can be used to solve the boundary value problem, the Fourier transform or the two-sided Laplace transform. The latter offers the advantage of representing a complex analytical function in the image space. Moreover, it is possible to obtain the characteristics of the generator in the image space (e. g. field configuration, power flow function, etc.). That implies a large simplification of mathematical treatment. The solution in the original space then is given by asymptotic expansion of the known image function. (author)

  3. High-voltage many-pulses generator with inductive energy store and fuse

    International Nuclear Information System (INIS)

    Kovalev, V.P.; Diyankov, V.S.; Kormilitsin, A.I.; Lavrent'ev, B.N.

    1996-01-01

    The high-voltage generator with inductive energy store and fuses as opening switch that generate series of powerful pulses is considered. This generator differs from the ordinary generator with inductive store by the cross-section of the series copper wires. The parameters of the wires are chosen based on empirical relations. The generation principle was tested on the two high-voltage generators with characteristic impedance 2.2 ohm, 4 ohm and with output voltages of 140 kV and 420 kV, respectively. Copper wires 0.1 to 0.23 mm in diameter were used. Series of 2 to 5 pulses of 100 to 300 ns duration, 400 to 1000 kV amplitude and 1 - 10 GW power were obtained. Pulses can be both the same and different. Two successive bremsstrahlung radiation pulses were obtain on the EMIR-M and IGUR-3 devices. Series power megavolt pulses can be generated with a power exceeding 10 11 W, pulse duration of 10 -3 to 10 -6 s, and time interval between them 10 -7 to 10 -5 s. (author). 4 figs., 2 refs

  4. High-voltage many-pulses generator with inductive energy store and fuse

    Energy Technology Data Exchange (ETDEWEB)

    Kovalev, V P; Diyankov, V S; Kormilitsin, A I; Lavrent` ev, B N [All-Russian Research Inst. of Technical Physics, Snezhinsk (Russian Federation)

    1997-12-31

    The high-voltage generator with inductive energy store and fuses as opening switch that generate series of powerful pulses is considered. This generator differs from the ordinary generator with inductive store by the cross-section of the series copper wires. The parameters of the wires are chosen based on empirical relations. The generation principle was tested on the two high-voltage generators with characteristic impedance 2.2 ohm, 4 ohm and with output voltages of 140 kV and 420 kV, respectively. Copper wires 0.1 to 0.23 mm in diameter were used. Series of 2 to 5 pulses of 100 to 300 ns duration, 400 to 1000 kV amplitude and 1 - 10 GW power were obtained. Pulses can be both the same and different. Two successive bremsstrahlung radiation pulses were obtain on the EMIR-M and IGUR-3 devices. Series power megavolt pulses can be generated with a power exceeding 10{sup 11} W, pulse duration of 10{sup -3} to 10{sup -6} s, and time interval between them 10{sup -7} to 10{sup -5} s. (author). 4 figs., 2 refs.

  5. Efficient generation of connectivity in neuronal networks from simulator-independent descriptions

    Directory of Open Access Journals (Sweden)

    Mikael eDjurfeldt

    2014-04-01

    Full Text Available Simulator-independent descriptions of connectivity in neuronal networks promise greater ease of model sharing, improved reproducibility of simulation results, and reduced programming effort for computational neuroscientists. However, until now, enabling the use of such descriptions in a given simulator in a computationally efficient way has entailed considerable work for simulator developers, which must be repeated for each new connectivity-generating library that is developed.We have developed a generic connection generator interface that provides a standard way to connect a connectivity-generating library to a simulator, such that one library can easily be replaced by another, according to the modeller's needs. We have used the connection generator interface to connect C++ and Python implementations of the connection-set algebra to the NEST simulator. We also demonstrate how the simulator-independent modelling framework PyNN can transparently take advantage of this, passing a connection description through to the simulator layer for rapid processing in C++ where a simulator supports the connection generator interface and falling-back to slower iteration in Python otherwise. A set of benchmarks demonstrates the good performance of the interface.

  6. Short-Circuit Fault Tolerant Control of a Wind Turbine Driven Induction Generator Based on Sliding Mode Observers

    Directory of Open Access Journals (Sweden)

    Takwa Sellami

    2017-10-01

    Full Text Available The installed energy production capacity of wind turbines is growing intensely on a global scale, making the reliability of wind turbine subsystems of greater significance. However, many faults like Inter-Turn Short-Circuit (ITSC may affect the turbine generator and quickly lead to a decline in supplied power quality. In this framework, this paper proposes a Sliding Mode Observer (SMO-based Fault Tolerant Control (FTC scheme for Induction Generator (IG-based variable-speed grid-connected wind turbines. First, the dynamic models of the wind turbine subsystems were developed. The control schemes were elaborated based on the Maximum Power Point Tracking (MPPT method and Indirect Rotor Flux Oriented Control (IRFOC method. The grid control was also established by regulating the active and reactive powers. The performance of the wind turbine system and the stability of injected power to the grid were hence analyzed under both healthy and faulty conditions. The robust developed SMO-based Fault Detection and Isolation (FDI scheme was proved to be fast and efficient for ITSC detection and localization.Afterwards, SMO were involved in scheming the FTC technique. Accordingly, simulation results assert the efficacy of the proposed ITSC FTC method for variable-speed wind turbines with faulty IG in protecting the subsystems from damage and ensuring continuous connection of the wind turbine to the grid during ITSC faults, hence maintaining power quality.

  7. Sizing of the Series Dynamic Breaking Resistor in a Doubly Fed Induction Generator Wind Turbine

    DEFF Research Database (Denmark)

    Soliman, Hammam; Wang, Huai; Zhou, Dao

    2014-01-01

    This paper investigates the effect of Series Dynamic Breaking Resistor (SDBR) sizing on a Doubly Fed Induction Generator (DFIG) based wind power conversion system. The boundary of the SDBR value is firstly derived by taking into account the controllability of the rotor side converter and the maxi......This paper investigates the effect of Series Dynamic Breaking Resistor (SDBR) sizing on a Doubly Fed Induction Generator (DFIG) based wind power conversion system. The boundary of the SDBR value is firstly derived by taking into account the controllability of the rotor side converter...... and the maximum allowable voltage of the stator. Then the impact of the SDBR value on the rotor current, stator voltage, DC-link voltage, reactive power capability and introduced power loss during voltage sag operation is evaluated by simulation. The presented study enables a trade-off sizing of the SDBR among...

  8. Condition monitoring of a wind turbine doubly-fed induction generator through current signature analysis

    Science.gov (United States)

    Artigao, Estefania; Honrubia-Escribano, Andres; Gomez-Lazaro, Emilio

    2017-11-01

    Operation and maintenance (O&M) of wind turbines is recently becoming the spotlight in the wind energy sector. While wind turbine power capacities continue to increase and new offshore developments are being installed, O&M costs keep raising. With the objective of reducing such costs, the new trends are moving from corrective and preventive maintenance toward predictive actions. In this scenario, condition monitoring (CM) has been identified as the key to achieve this goal. The induction generator of a wind turbine is a major contributor to failure rates and downtime where doubly-fed induction generators (DFIG) are the dominant technology employed in variable speed wind turbines. The current work presents the analysis of an in-service DFIG. A one-year measurement campaign has been used to perform the study. Several signal processing techniques have been applied and the optimal method for CM has been identified. A diagnosis has been reached, the DFIG under study shows potential gearbox damage.

  9. Overall control strategy of variable speed doubly-fed induction generator wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Anca D.; Soerensen, Poul [Risoe National Laboratory, Roskilde (Denmark). Wind Energy Dept.; Iov, Florin; Blaabjerg, Frede [Aalborg Univ. (Denmark). Inst. of Energy Technology

    2004-07-01

    The variable speed doubly-fed induction generator wind turbine is today the most widely used concept. The paper presents an overall control system of the variable speed DFIG wind turbine, with focus on the control strategies and algorithms applied at each hierarchical control level of the wind turbine. The present control method is designed for normal continuous operations. The strongest feature of the implemented control method is that it allows the turbine to operate with the optimum power efficiency over a wider range of wind speeds. The variable speed/variable pitch wind turbine with doubly-fed induction generator is implemented in the dynamic power system simulation tool DIgSILENT. Simulation results are performed and analyzed in different normal operating conditions.

  10. Hysteresis Control for a DC Connected Synchronous Generator

    DEFF Research Database (Denmark)

    Rasmussen, Tonny Wederberg; Evangelos, Dimarakis

    2009-01-01

    Abstract— for offshore wind farms the distance to the coast increases, therefore DC cables will have to be used. For a variable speed wind turbine a rectifier and a synchronous generator with a boost converter is used. As a new suggestion for control the generator speed hysteresis control...

  11. Induction generator model in phase coordinates for fault ride-through capability studies of wind turbines

    DEFF Research Database (Denmark)

    Fajardo, L.A.; Iov, F.; Medina, R.J.A.

    2007-01-01

    A phase coordinates induction generator model with time varying electrical parameters as influenced by magnetic saturation and rotor deep bar effects, is presented in this paper. The model exhibits a per-phase formulation, uses standard data sheet for characterization of the electrical parameters...... are conducted in a representative sized system and results show aptness of the proposed model over other two models. This approach is also constructive to support grid code requirements....

  12. Observer Based Estimation of Stator Winding Faults in Delta-connected Induction Motors, a LMI Approach

    DEFF Research Database (Denmark)

    Kallesøe, Carsten; Vadstrup, Pierre; Rasmussen, Henrik

    2006-01-01

    This paper addresses the subject of inter-turn short circuit estimation in the stator of an induction motor. In the paper an adaptive observer scheme is proposed. The proposed observer is capable of simultaneously estimating the speed of the motor, the amount turns involved in the short circuit...... and an expression of the current in the short circuit. Moreover the states of the motor are estimated, meaning that the magnetizing currents are made available even though a fault has happened in the motor. To be able to develop this observer, a model particular suitable for the chosen observer design, is also...... derived. The efficiency of the proposed observer is demonstrated by tests performed on a test setup with a customized designed induction motor. With this motor it is possible to simulate inter-turn short circuit faults....

  13. Serially-Connected Compensator for Eliminating the Unbalanced Three-Phase Voltage Impact on Wind Turbine Generators: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Z.; Hsu, P.; Muljadi, E.; Gao, W.

    2015-04-06

    Untransposed transmission lines, unbalanced tap changer operations, and unbalanced loading in weak distribution lines can cause unbalanced-voltage conditions. The resulting unbalanced voltage at the point of interconnection affects proper gird integration and reduces the lifetime of wind turbines due to power oscillations, torque pulsations, mechanical stresses, energy losses, and uneven and overheating of the generator stator winding. This work investigates the dynamic impact of unbalanced voltage on the mechanical and electrical components of integrated Fatigue, Aerodynamics, Structures, and Turbulence (FAST) wind turbine generation systems (WTGs) of Type 1 (squirrel-cage induction generator) and Type 3 (doubly-fed induction generator). To alleviate this impact, a serially-connected compensator for a three-phase power line is proposed to balance the wind turbine-side voltage. Dynamic simulation studies are conducted in MATLAB/Simulink to compare the responses of these two types of wind turbine models under normal and unbalanced-voltage operation conditions and demonstrate the effectiveness of the proposed compensator.

  14. Development of the Electromagnetic Induction Type Micro Air Turbine Generator Using MEMS and Multilayer Ceramic Technology

    International Nuclear Information System (INIS)

    Iiduka, A; Ishigaki, K; Takikawa, Y; Ohse, T; Saito, K; Uchikoba, F

    2011-01-01

    The miniaturized electromagnetic induction type air turbine generator is described. The micro air turbine generator rotated by the compressed air and generating electricity was fabricated by the combination of MEMS and multilayer ceramic technology. The micro generator consisted of an air turbine and a magnetic circuit. The turbine part consisted of 7 silicon layers fabricated by the MEMS technology. The magnetic circuit was fabricated by the multilayer ceramic technology based on the green sheet process. The magnetic material used in the circuit was ferrite, and the internal conductor was silver. The dimensions of the obtained generator were 3.5x4x3.5 mm. The output power was 1.92 μW. From FEM analysis of the magnetic flux, it was found that leakage of the flux affected the output power.

  15. The Impact of Connecting Distributed Generation to the Distribution System

    Directory of Open Access Journals (Sweden)

    E. V. Mgaya

    2007-01-01

    Full Text Available This paper deals with the general problem of utilizing of renewable energy sources to generate electric energy. Recent advances in renewable energy power generation technologies, e.g., wind and photovoltaic (PV technologies, have led to increased interest in the application of these generation devices as distributed generation (DG units. This paper presents the results of an investigation into possible improvements in the system voltage profile and reduction of system losses when adding wind power DG (wind-DG to a distribution system. Simulation results are given for a case study, and these show that properly sized wind DGs, placed at carefully selected sites near key distribution substations, could be very effective in improving the distribution system voltage profile and reducing power losses, and hence could  improve the effective capacity of the system. 

  16. Technical guide to the connection of generation to the distribution network

    Energy Technology Data Exchange (ETDEWEB)

    Jarrett, K.; Hedgecock, J.; Gregory, R.; Warham, T.

    2003-07-01

    This guide provides a 'route map' of the processes of getting a generation scheme connected to the network and is intended to help developers of any form of distributed generation connected to the UK's local electricity networks, eg: renewable energy schemes; waste-to-energy schemes; on-site generation and combined heat and power (CHP) schemes; and peak lopping schemes using back-up generators. Where necessary, the guide distinguishes between arrangements that apply in Scotland and those that apply in England and Wales. The guide aims to: provide background information about the electricity industry; highlight common technical issues that arise during connection negotiation and their implications for distribution network operators (DNOs) and developers; examine the main factors affecting connection costs and timescales for achieving connections; and identify the different types of contracts relating to connection. The report considers the connection process, the connection application process and timescales, costs and charges, competition in connection, the structure of the UK electricity industry, the statutory framework, the effects of distributed generation of the distribution system, earthing and protection design, safety issues and DNO network information. It includes a glossary, checklists, useful contact details and information about standards and other useful documents.

  17. Effects of Capcitor Bank on Fault Ride Through Capibility of Induction Generator Based Wind Turbines

    DEFF Research Database (Denmark)

    Hu, Y; Chen, Zhe

    2010-01-01

    power system stability and supply security. Some existing wind turbines are still based on fixed speed induction generators, the effects of capacitor bank on such generators are discussed in this paper. The simulation study shows the capacitor bank may costeffectively improve the dynamic performance......Wind turbine installation is increasing rapidly. In some networks, wind power penetration is significantly high and the performance of wind turbine plays an important role in power system operation and control. Especially, the behavior of wind turbines during a power system disturbance would affect...

  18. Effects of Wind Turbines Equipped with Doubly-fed Induction Generators on Distance Protection

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    Nowadays wind energy is the fastest growing renewable energy resource in the world. The problems of integrating wind farms are caused by changes of wind speed during a day. Moreover, the behaviors of wind turbines equipped with doubly-fed induction generators differ fundamentally from synchronous generators. Therefore, more considerations are needed to analyze the performances of the distance protection relays. The protection of a wind farm with distance relay is inspected. By changing the conditions of the wind farm, the characteristics of the distance relay are studied.

  19. Study on the plasma generation characteristics of an induction-triggered coaxial pulsed plasma thruster

    Science.gov (United States)

    Weisheng, CUI; Wenzheng, LIU; Jia, TIAN; Xiuyang, CHEN

    2018-02-01

    At present, spark plugs are used to trigger discharge in pulsed plasma thrusters (PPT), which are known to be life-limiting components due to plasma corrosion and carbon deposition. A strong electric field could be formed in a cathode triple junction (CTJ) to achieve a trigger function under vacuum conditions. We propose an induction-triggered electrode structure on the basis of the CTJ trigger principle. The induction-triggered electrode structure could increase the electric field strength of the CTJ without changing the voltage between electrodes, contributing to a reduction in the electrode breakdown voltage. Additionally, it can maintain the plasma generation effect when the breakdown voltage is reduced in the discharge experiments. The induction-triggered electrode structure could ensure an effective trigger when the ablation distance of Teflon increases, and the magnetic field produced by the discharge current could further improve the plasma density and propagation velocity. The induction-triggered coaxial PPT we propose has a simplified trigger structure, and it is an effective attempt to optimize the micro-satellite thruster.

  20. Active Power and Flux Control of a Self-Excited Induction Generator for a Variable-Speed Wind Turbine Generation

    Energy Technology Data Exchange (ETDEWEB)

    Na, Woonki; Muljadi, Eduard; Leighty, Bill; Kim, Jonghoon

    2017-05-11

    A Self-Excited Induction Generation (SEIG) for a variable speed wind turbine generation(VS-WG) is normally considered to be a good candidate for implementation in stand-alone applications such as battery charging, hydrogenation, water pumping, water purification, water desalination, and etc. In this study, we have examined a study on active power and flux control strategies for a SEIG for a variable speed wind turbine generation. The control analysis for the proposed system is carried out by using PSCAD software. In the process, we can optimize the control design of the system, thereby enhancing and expediting the control design procedure for this application. With this study, this control design for a SEIG for VS-WG can become the industry standard for analysis and development in terms of SEIG.

  1. Torque control of synchronous and induction generators for variable speed operation of wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Ola; Ulen, E. [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Electric Power Engineering

    1996-12-01

    The aim of this paper is to investigate variable speed electrical systems. Synchronous generators with diode rectifiers and line-commutated thyristor converters are compared with induction generators with force commutated transistor converters and scalar control. The system characteristics are examined regarding possible speed of response (bandwidth) of the torque control, including the sensitivity to disturbances for the drive train and also the possibility to get damping of the drive train resonance. Analyses, simulations and laboratory tests with a 40 kW machine set-up have been performed. The investigation shows that the system with synchronous generator is well suited for wind power applications. A rapid standard DC-current regulator is included in the torque control and can be used for damping of the resonance. The torque control has a bandwidth up to about 3 Hz and the DC-voltage controller up to about 1 Hz. The system with induction generator with scalar control (no transformations) is more difficult to control. A linear approach is only possible up to about 1.5 Hz. In this region it turns out that the behaviour can be visualized as an added inertia on the generator side that can be rather big. 4 refs, 9 figs

  2. Grid-connected solar power generation a utility's view

    International Nuclear Information System (INIS)

    Weiner, D.; Meron, G.; Fisher, D.

    1994-01-01

    The purpose of this paper is to analyze these new means of production from the electric utility point of view. This analysis will take into account the experience gained by Israel Electric Corporation while operating three demonstration plants. In addition, a techno-economic evaluation photovoltaic and thermal systems is presented and compared to that of conventional generation

  3. Study on transient stability of wind turbine with induction generator based on variable pitch control strategy

    DEFF Research Database (Denmark)

    Zhao, B.; Li, H.; Han, L.

    2011-01-01

    In order to enhance and improve the transient stability of a grid-connected wind turbine generator system under the power grid fault, based on typical pitch control strategy of wind turbine, considering the wind turbine system oscillation caused by the drive-train shaft flexibility, Based on Matl...

  4. Issues and regulatory requirements for the connection of wind generation

    Energy Technology Data Exchange (ETDEWEB)

    Gimenez Alvarez, J.M. [National University of San Juan (Argentina)], E-mail: jgimenez@unsj.edu.ar; Gomez Targarona, J.C. [National University of Rio Cuarto, Cordoba (Argentina). Electric Power Systems Protection Institute (IPSEP)], E-mail: jcgomez@ing.unrc.edu.ar

    2009-07-01

    Pollution problems such as greenhouse effect as well as the high value and volatility of fuel prices have forced and accelerated the development and use of renewable energy sources. In this work a complete revision of wind generation is presented. In the first part a brief history of the wind energy developments is detailed. Next, some commentaries related to the present and future state are made. Then, a revision of the modern structures of wind generation is realized. In fourth place it is included a brief comparison between small and big size turbines. Then, different types of energy storage are mentioned. Finally regulatory aspects are discussed, respect to the treatment of the technical problems. (author)

  5. Special issue on advancing grid-connected renewable generation systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Yang, Yongheng

    2017-01-01

    Renewables are heavily involved in power generation, as an essential component for today’s energy paradigm. Energy structure—both national and international—has been undergoing significant changes over the past few decades. For instance, in Denmark, power generation is shifting from fossil......-fuel-based to renewable-based in terms of energy sources, from centralized to decentralized in terms of architectures, and from sole to miscellaneous in terms of energy varieties [1]. In this energy evolution, the power electronic technology plays an enabling role in the integration and advancements of renewables......—such as wind turbine, photovoltaics, fuel cells, and other emerging energy systems. At the same time, various control strategies are necessary to guide the energy integration (i.e., to enhance the energy transition), and on the other hand, to flexibly, reliably, and efficiently utilize the energy. Tremendous...

  6. Economic aspects of grid connected solar electricity generation

    International Nuclear Information System (INIS)

    Pharabod, F.

    1993-01-01

    Experience gained with available solar thermal technologies enlighten on options for research and development on solar electricity generation. The proposed analysis of new solar technologies concerns market, costs and profit viewpoint: - Systems under development have to fit with consumers' needs and utilities' specifications, technology is not the only item to study. - Expense headings depend on technological options and operation procedures such as size of the plant, solar only or hybrid concept. - Anticipation of revenues highly depends on direct insolation quality and on local conditions for introducing the electric power generated into the network: daily direct insolation measurements and annual local load curve are prerequisite data. Strategic advantages regarding environment and sustainable development are to be pointed out, specially in industrialized countries or for projects including financing institutions. As far as generating electric power on the grid is a major challenge in the development of a number of countries in the sun belt, cooperation between industrialized and developing countries, under the auspices of international organization, has to be promoted. (Author) 12 refs

  7. Investigation on magnetoacoustic signal generation with magnetic induction and its application to electrical conductivity reconstruction

    International Nuclear Information System (INIS)

    Ma Qingyu; He Bin

    2007-01-01

    A theoretical study on the magnetoacoustic signal generation with magnetic induction and its applications to electrical conductivity reconstruction is conducted. An object with a concentric cylindrical geometry is located in a static magnetic field and a pulsed magnetic field. Driven by Lorentz force generated by the static magnetic field, the magnetically induced eddy current produces acoustic vibration and the propagated sound wave is received by a transducer around the object to reconstruct the corresponding electrical conductivity distribution of the object. A theory on the magnetoacoustic waveform generation for a circular symmetric model is provided as a forward problem. The explicit formulae and quantitative algorithm for the electrical conductivity reconstruction are then presented as an inverse problem. Computer simulations were conducted to test the proposed theory and assess the performance of the inverse algorithms for a multi-layer cylindrical model. The present simulation results confirm the validity of the proposed theory and suggest the feasibility of reconstructing electrical conductivity distribution based on the proposed theory on the magnetoacoustic signal generation with magnetic induction

  8. Dual-loop self-optimizing robust control of wind power generation with Doubly-Fed Induction Generator.

    Science.gov (United States)

    Chen, Quan; Li, Yaoyu; Seem, John E

    2015-09-01

    This paper presents a self-optimizing robust control scheme that can maximize the power generation for a variable speed wind turbine with Doubly-Fed Induction Generator (DFIG) operated in Region 2. A dual-loop control structure is proposed to synergize the conversion from aerodynamic power to rotor power and the conversion from rotor power to the electrical power. The outer loop is an Extremum Seeking Control (ESC) based generator torque regulation via the electric power feedback. The ESC can search for the optimal generator torque constant to maximize the rotor power without wind measurement or accurate knowledge of power map. The inner loop is a vector-control based scheme that can both regulate the generator torque requested by the ESC and also maximize the conversion from the rotor power to grid power. An ℋ(∞) controller is synthesized for maximizing, with performance specifications defined based upon the spectrum of the rotor power obtained by the ESC. Also, the controller is designed to be robust against the variations of some generator parameters. The proposed control strategy is validated via simulation study based on the synergy of several software packages including the TurbSim and FAST developed by NREL, Simulink and SimPowerSystems. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  9. Analysis of Unbalanced Magnetic Pull in Wound Rotor Induction Machines using Finite Element Analysis – Transient, Motoring and Generating Modes

    DEFF Research Database (Denmark)

    Dorrell, David G.; Hermann, Alexander Niels August; Jensen, Bogi Bech

    2013-01-01

    eccentricity. The operating conditions are varied so that transient, motoring and doubly-fed induction generator modes are studied. This allows greater understanding of the radial forces involved. Wound rotor induction machines exhibit higher unbalanced magnetic pull than cage induction machines so......There has been much literature on unbalanced magnetic pull in various types of electrical machine. This can lead to bearing wear and additional vibrations in the machine. In this paper a wound rotor induction is studied. Finite element analysis studies are conducted when the rotor has 10 % rotor...

  10. Control strategies for gas turbine generators for grid connected and islanding operations

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2010-01-01

    fine while a DG is connected to a grid, might not work as desired while it is islanded and vise versa. This paper presents a strategy to operate distribution systems with a small gas turbine generator (GTG), which is capable of supplying local loads, in both islanding and grid connected conditions...

  11. Wind Turbine Power Generation Emulation Via Doubly Fed Induction Generator Control

    Science.gov (United States)

    2009-12-01

    vde thetas vqs_pu vds_pu synchronous...to stationary 0 ide_ref 200 Vdc_ref I_ref I_meas vqe PI iq I_ref I_meas vde PI id v_ref v_meas iqs PI Vdc 4 theta_s 3 ide 2 iqe 1 Vdc 21 between...1-1 x(-1)- a b a + b+ Sy stem Generator Variac P/S 60V 60HzVariac P/S 60V 60Hz 70 Vabc_s THETA CALCULATION 5 vde 4 vqe 3 Vas 2 Vdc_out 1

  12. Induction heating to trigger the nickel surface modification by in situ generated 4-carboxybenzene diazonium

    Science.gov (United States)

    Arrotin, Bastien; Jacques, Amory; Devillers, Sébastien; Delhalle, Joseph; Mekhalif, Zineb

    2016-05-01

    Nickel is commonly used in numerous applications and is one of the few materials that present strong ferromagnetic properties. These make it a suitable material for induction heating which can be used to activate the grafting of organic species such as diazonium salts onto the material. Diazonium compounds are often used for the modification of metals and alloys thanks to their easy chemical reduction onto the substrates and the possibility to apply a one-step in situ generation process of the diazonium species. This work focuses on the grafting of 4-aminocarboxybenzene on nickel substrates in the context of a spontaneous grafting conducted either at room temperature or by thermal assistance through conventional heating and induction heating. These modifications are also carried out with the goal of maintaining the oxides layer as much as possible unaffected. The benefits of using induction heating with respect to conventional heating are an increase of the grafting rate, a better control of the reaction and a slighter impact on the oxides layer.

  13. Modeling and Simulation of a Wind Turbine Driven Induction Generator Using Bond Graph

    Directory of Open Access Journals (Sweden)

    Lachouri Abderrazak

    2015-12-01

    Full Text Available The objective of this paper is to investigate the modelling and simulation of wind turbine applied on induction generator with bond graph methodology as   a graphical and multi domain approach. They provide a precise and unambiguous modelling tool, which allows for the specification of hierarchical physical structures. The paper begins with an introduction to the bond graphs technique, followed by an implementation of the wind turbine model. Simulation results illustrate the simplified system response obtained using the 20-sim software.

  14. Modern control strategies of doubly-fed induction generator based wind turbine system

    DEFF Research Database (Denmark)

    Zhou, Dao; Song, Yipeng; Blaabjerg, Frede

    2016-01-01

    A doubly-fed induction generator (DFIG) based configuration is still preferred by wind turbine manufactures due to the cost-effective power converter and independent control of the active power and reactive power. To cope with stricter grid codes (e.g. reactive power compensation, low voltage ride......, with the control targets of the smooth active and reactive power or the balances and sinusoidal current of the rotor-side converter and the grid-side converter. Finally, a bandwidth based repetitive controller is evaluated to improve the DFIG system's robustness against grid frequency deviation....

  15. Advanced control of a doubly-fed induction generator for wind energy conversion

    Energy Technology Data Exchange (ETDEWEB)

    Poitiers, F.; Bouaouiche, T.; Machmoum, M. [Institut de Recherche en Electronique et Electrotechnique de Nantes Atlantique, rue Christian Pauc, 44306 Nantes (France)

    2009-07-15

    The aim of this paper is to propose a control method for a doubly-fed induction generator used in wind energy conversion systems. First, stator active and reactive powers are regulated by controlling the machine inverter with three different controllers: proportional-integral, polynomial RST based on pole placement theory and Linear Quadratic Gaussian. The machine is tested in association with a wind-turbine emulator. Secondly a control strategy for the grid-converter is proposed. Simulations results are presented and discussed for each converter control and for the whole system. (author)

  16. Operation of LIA-30 linear induction accelerator in the mode of generation of two bremsstrahlung pulses

    Energy Technology Data Exchange (ETDEWEB)

    Bossamykin, V S; Gerasimov, A I; Gordeev, V S; Grishin, A V; Gritsina, V P; Tarasov, A D; Fedotkin, A S; Lazarev, S A; Averchenkov, A Ya [All-Russian Scientific Research Institute of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    The operating mode was studied of the LIA-30 linear induction accelerator ({approx} 40 MeV, {approx} 100 kA, {approx} 30 ns) with the generation of two bremsstrahlung pulses separated by a specified time interval from 0 to 5 {mu}s. In the accelerating channel an additional tube cathode was installed, and a synchronization system for two accelerating module groups triggering the formation and acceleration, at different initial times, of two annular electron beams with different outer diameters was changed. The energy limit of each beam electron acceleration can be controlled, and the energy sum limit is {<=} 540 MeV. (author). 2 tabs., 2 figs.

  17. Centralised power control of wind farm with doubly fed induction generators

    DEFF Research Database (Denmark)

    Hansen, A.D.; Sørensen, Poul Ejnar; Iov, F.

    2006-01-01

    At the moment, the control ability of wind farms is a prime research concern for the grid integration of large wind farms, due to their required active role in the power system. This paper describes the on-going work of a research project, whose overall objective is to analyse and assess...... the possibilities for control of different wind farm concepts. The scope of this paper is the control of a wind farm made up exclusively of doubly fed induction generators. The paper addresses the design and implementation issues of such a controller and focuses on the ability of the wind farm control strategy...

  18. Comparison of control strategies for Doubly fed induction generator under recurring grid faults

    DEFF Research Database (Denmark)

    Chen, Wenjie; Blaabjerg, Frede; Zhu, Nan

    2014-01-01

    The new grid codes demand the wind turbine systems to ride through recurring grid faults. Many control strategies have been proposed for the Doubly Fed Induction Generator under single grid fault, but their performance under recurring grid faults have not been studied yet. In this paper, five...... different control strategies for DFIG to ride through single grid faults are presented, and their performance under recurring grid faults are analyzed. The controllable range, stator time constant and torque fluctuations of the DFIG with different control strategies are compared. The results are verified...

  19. Doubly fed induction generator based wind turbine systems subject to recurring grid faults

    DEFF Research Database (Denmark)

    Chen, Wenjie; Blaabjerg, Frede; Zhu, Nan

    2014-01-01

    New grid codes demand the wind turbine systems to ride through recurring grid faults. In this paper, the performance of the Doubly Fed Induction Generator wind turbine system under recurring grid faults is analyzed. The stator natural flux produced by the voltage recovery after the first grid fault...... may be superposed on the stator natural flux produced by the second grid fault, and it may result in large current and voltage transient. The damping of the stator natural flux can be accelerated with a rotor natural current in its opposite direction after voltage recovery, but larger torque....... The performance of DFIG under recurring grid faults is verified by the simulation and experiments....

  20. New control strategy of stand-alone brushless doubly-fed induction generator for supplying unbalanced loads in ship shaft power generation system

    DEFF Research Database (Denmark)

    Liu, Yi; Xu, Wei; Xiong, Fei

    2017-01-01

    The ship shaft power generation system based on a stand-alone brushless doubly-fed induction generator (BDFIG) have demonstrated excellent saving-energy performance. This paper presents a new control scheme of the stand-alone BDFIG for supplying unbalanced loads in the ship shaft power generation...

  1. Generation of heat on fuel rod in cosine pattern by using induction heating

    International Nuclear Information System (INIS)

    Keettikkal, Felix; Sajeesh, Divya; Rao, Poornima; Hande, Shashank; Dakave, Ganesh; Kute, Tushar; Mahajan, Akshay; Kulkarni, R.D.

    2017-01-01

    Fuel rods are used in a nuclear reactor for fission process. When these rods are cooled by water during the heat transfer, the temperature stress causes undesirable defects in the fuel rod. Studying these defects occurring in the fuel rod in the nuclear cluster during nuclear reaction is a difficult task because fission reaction makes it difficult to analyse the changes in the rod. Hence there is a need to use a replica of the rod with similar thermal stress to study and analyse the rod for the defects. Normally the heat generated on the fuel rod follows a cosine pattern which is an inherent characteristic inside a nuclear reactor. In view of this, in this paper induction heating method is used on a rod to create an exact replica of the cosine pattern of heat by varying the pitch of the coil. First, a MATLAB simulation is done using simulink. Then a prototype of the model has been developed comprising of carbon steel pipe, with length and outside diameter of 1 meter and 48.2 mm, respectively. Instead of using water as coolant, rod is simulated in air. Therefore, the heat generated is lost by normal convection and radiation. Non-nuclear testing can be a valuable tool in the development or in some kind of experiment using nuclear reactor. Induction heating becomes an alternative to classical heating technologies because of its advantages such as efficiency, quickness, safety, clean heating and accurate power control. (author)

  2. Minimum short-circuit ratios for grid interconnection of wind farms with induction generators

    Energy Technology Data Exchange (ETDEWEB)

    Reginatto, Romeu; Rocha, Carlos [Western Parana State University (UNIOESTE), Foz do Iguacu, PR (Brazil). Center for Engineering and Exact Sciences], Emails: romeu@unioeste.br, croberto@unioeste.br

    2009-07-01

    This paper concerns the problem of determining the minimum value for the short-circuit ratio which is adequate for the interconnection of a given wind farms to a given grid point. First, a set of 3 criteria is defined in order to characterize the quality/safety of the interconnection: acceptable terminal voltage variations, a minimum active power margin, and an acceptable range for the internal voltage angle. Then, the minimum short circuit ratio requirement is determined for 6 different induction generator based wind turbines, both fixed-speed (with and without reactive power compensation) and variable-speed (with the following control policies: reactive power, power factor, and terminal voltage regulation). The minimum short-circuit ratio is determined and shown in graphical results for the 6 wind turbines considered, for X/R in the range 0-15, also analyzing the effect of more/less stringent tolerances for the interconnection criteria. It is observed that the tighter the tolerances the larger the minimum short-circuit ratio required. For the same tolerances in the interconnection criteria, a comparison of the minimum short circuit ratio required for the interconnection of both squirrel-cage and doubly-fed induction generators is presented, showing that the last requires much smaller values for the short-circuit ratio. (author)

  3. Optimal design of power system stabilizer for power systems including doubly fed induction generator wind turbines

    International Nuclear Information System (INIS)

    Derafshian, Mehdi; Amjady, Nima

    2015-01-01

    This paper presents an evolutionary algorithm-based approach for optimal design of power system stabilizer (PSS) for multi-machine power systems that include doubly fed induction generator wind turbines. The proposed evolutionary algorithm is an improved particle swarm optimization named chaotic particle swarm optimization with passive congregation (CPSO-PC) applied for finding the optimal settings of PSS parameters. Two different eigenvalue-based objectives are combined as the objective function for the optimization problem of tuning PSS parameters. The first objective function comprises the damping factor of lightly damped electro-mechanical modes and the second one includes the damping ratio of these modes. The effectiveness of the proposed method to design PSS for the power systems including DFIG (Doubly Fed Induction Generator) is extensively demonstrated through eigenvalue analysis and time-domain simulations and also by comparing its simulation results with the results of other heuristic optimization approaches. - Highlights: • A new optimization model for design of PSS in power systems including DFIG is proposed. • A detailed and realistic modeling of DFIG is presented. • A new evolutionary algorithm is suggested for solving the optimization problem of designing PSS

  4. Analysis of wind driven self-excited induction generator supplying isolated DC loads

    Directory of Open Access Journals (Sweden)

    Khaled S. Sakkoury

    2017-05-01

    Full Text Available This paper presents the analysis, modelling and simulation of wind-driven self-excited induction generator (SEIG. The three-phase SEIG is driven by a variable-speed prime mover to represent a wind turbine. Also, the paper investigates the dynamic performance of the SEIG during start-up, increasing or decreasing the load or rotor speed. The value of the excitation capacitance required for the SEIG is calculated to give suitable saturation level to assure self-excitation and to avoid heavy saturation levels. Matching of the maximum power available from the wind turbine is performed through varying the load value. The effect of AC–DC power conversion on the generator is investigated. The system simulation is carried out using MATLAB/SIMULINK toolbox program.

  5. Speed-sensorless control strategy for multi-phase induction generator in wind energy conversion systems

    Directory of Open Access Journals (Sweden)

    Dumnić Boris P.

    2016-01-01

    Full Text Available Renewable energy sources, especially wind energy conversion systems (WECS, exhibit constant growth. Increase in power and installed capacity led to advances in WECS topologies. Multi-phase approach presents a new development direction, with several key advantages over three-phase systems. Paired with a sensorless control strategy, multi-phase machines are expected to take primacy over standard solutions. This paper presents speed sensorless vector control of an asymmetrical six-phase induction generator based on a model reference adaptive system (MRAS. Suggested topology and developed control algorithm show that sensorless control can yield appropriate dynamic characteristics for the use in WECS with increase in reliability and robustness. [Projekat Ministarstva nauke Republike Srbije, br. III 042004: Smart Electricity Distribution Grids Based on Distribution Management System and Distributed Generation

  6. MOSFET-based high voltage double square-wave pulse generator with an inductive adder configuration

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Xin [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Xi' an 710049 (China); Zhang, Qiaogen, E-mail: hvzhang@mail.xjtu.edu.cn [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Xi' an 710049 (China); Long, Jinghua [College of Physics, Shenzhen University, Shenzhen 518060 (China); Lei, Yunfei; Liu, Jinyuan [Institute of Optoelectronics, Shenzhen University, Shenzhen 518060 (China)

    2015-09-01

    This paper presents a fast MOSFET-based solid-state pulse generator for high voltage double square-wave pulses. The generator consists mainly of an inductive adder system stacked of 20 solid-state modules. Each of the modules has 18 power MOSFETs in parallel, which are triggered by individual drive circuits; these drive circuits themselves are synchronously triggered by a signal from avalanche transistors. Our experiments demonstrate that the output pulses with amplitude of 8.1 kV and peak current of about 405 A are available at a load impedance of 20 Ω. The pulse has a double square-wave form with a rise and fall time of 40 ns and 26 ns, respectively and bottom flatness better than 12%. The interval time of the double square-wave pulses can be adjustable by varying the interval time of the trigger pulses.

  7. Experimental stand-alone self-excited induction generator driven by a diesel motor

    Directory of Open Access Journals (Sweden)

    Mhamdi Taoufik

    2017-12-01

    Full Text Available This paper presents an experimental work to design and size a diesel generator (DG. The basic system is equipped with a 1.5 kW self-excited induction generator (SEIG, a diesel motor (DM, a static voltage compensator (SVC and controllers. A proportional integral controller is used to meet the requirement of the SEIG frequency regulation. A controlled voltage source is performed by using an SVC with a fuzzy controller, which adjusts voltage by varying the amount of the injected reactive power. An experimental set-up is used to identify the SEIG parameters and select the convenient bank of capacitors that minimize the SEIG starting up time and fix the convenient margin of voltage. The system has been tested by simulation using models implemented by Matlab/Simulink software. The simulation results confirm the efficiency of the proposed strategy of voltage regulation. Keywords: Diesel motor, SEIG, SVC, Voltage regulation, Frequency regulation

  8. ANALYSIS OF THE SPECIAL FEATURES OF THE THERMAL PROCESS IN AN INDUCTION GENERATOR AT HIGH SATURATION OF THE MAGNETIC SYSTEM

    Directory of Open Access Journals (Sweden)

    V. Chenchevoi

    2017-06-01

    Full Text Available Purpose. Development of the method for the assessment of the thermal operation modes of an autonomous electrical power system with an induction motor, aiming at improvement of the reliability of electricity supply and the quality of electric energy. Methodology. Induction generator mathematical modeling taking into account the magnetic system saturation was used in the research. A heat model taking into account the excess of the temperature of the induction generator units in the mode of high saturation was developed. The obtained results were compared with the experimental data. Results. The paper contains the solution to the problem of improvement of the mathematical model sand methods for steel losses determination in there search of the operation modes of an autonomous uncontrolled induction generator taking into consideration the properties of the magnetic system in the mode of high saturation. The expression for determination of steel losses in the mode of high saturation is obtained. It enables the assessment of the induction generator thermal condition. Originality. The analytical dependence for the calculation of the steel losses in the mode of magnetic system saturation has been obtained for the first time. Practical value. The obtained expression for the calculation of the steel losses can be used for determination of the admissible time of generator operation at overload. It will allow avoiding broken winding insulation and complete use of the generator overload capacity. As a result, it will reduce possible irregularities of electricity supply due to the generator preliminary cutoff.

  9. Solar photovoltaic systems and their use as grid-connected generators in the United Kingdom

    Energy Technology Data Exchange (ETDEWEB)

    Munro, D K; Hacker, R J; Thornycroft, J M [Halcrow Gilbert Associates Ltd., Swindon (United Kingdom)

    1995-10-01

    There is an increasing interest in the use of building-integrated solar photovoltaic generators as grid-connected generators. This paper discusses the experience with this technology in Europe. Typical systems and their integration into domestic and non-domestic buildings are described. Information is provided on the energy output that can be expected from the systems and the economics of their use. The paper provides an overview of the requirements for photovoltaic systems as grid-connected generation plant in the United Kingdom. (Author)

  10. ASP - Grid connections of large power generating units; ASP - Anslutning av stoerre produktionsanlaeggningar till elnaetet

    Energy Technology Data Exchange (ETDEWEB)

    Larsson, Aake; Larsson, Richard [Vattenfall Power Consultants, Stockholm (Sweden)

    2006-12-15

    Grid connections of large power generating units normally require more detailed studies compared to small single units. The required R and D-level depends on the specific characteristics of the production units and the connecting grid. An inquiry for a grid connection will raise questions for the grid owner regarding transmission capability, losses, fault currents, relay protection, dynamic stability etc. Then only a few larger wind farms have been built, the experiences from these types of grid connections are limited and for that reason it can be difficult to identify issues appropriate for further studies. To ensure that electric power generating units do not have unacceptable impact on the grid, directions from the Swedish TSO (Svenska Kraftnaet) have been stated. The directions deal, for example, with power generation in specific ranges of voltage level and frequency and the possibility to remain connected to the grid when different faults occur. The requirements and the consequences of these directions are illustrated. There are three main issues that should be considered: Influence on the power flow from generating units regarding voltage level, currents, losses etc.; Different types of electric systems in generating units contribute to different levels of fault currents. For that reason the resulting fault current levels have to be studied; It is required that generating units should remain connected to the grid at different modes of operation and faults. These modes have to be verified. Load flow and dynamic studies normally demand computer models. Comprehensive models, for instance of wind farms, can bee difficult to design and normally large computer capacity is required. Therefore simplified methods to perform relevant studies are described. How to model an electric power generating unit regarding fault currents and dynamic stability is described. An inquiry for a grid connection normally brings about a discussion concerning administration. To make it

  11. Full-load converter connected asynchronous generators for MW class wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Akhmatov, Vladislav

    2005-06-15

    Wind turbines equipped with full-load converter-connected asynchronous generators are a known concept. These have rating up to hundreds of kW and are a feasible concept for MW class wind turbines and may have advantages when compared to conventional wind turbines with directly connected generators. The concept requires the use of full-scale frequency converters, but the mechanical gearbox is smaller than in conventional wind turbines of the same rating. Application of smaller gearbox may reduce the no-load losses in the wind turbines, which is why such wind turbines with converter connected generators may start operation at a smaller wind speed. Wind turbines equipped with such converted connected asynchronous generators are pitch-controlled and variable-speed. This allows better performance and control. The converter control may be applied to support the grid voltage at short-circuit faults and to improve the fault-ride-through capability of the wind turbines, which makes the concepts relevant for large wind farms. The Danish transmission system operator Energinet-DK has implemented the general model of wind turbines equipped with converter connected asynchronous generators with the simulation tool Powerfactory (DlgSilent). The article presents Energinet-DK's experience of modeling this feasible wind turbine concept. (Author)

  12. Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate

    Directory of Open Access Journals (Sweden)

    M. J. Abbasi

    2016-12-01

    Full Text Available The doubly fed induction generator (DFIG is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE event is among the most frequent failures in electric generators. However, LOE detection studies heretofore were usually confined to synchronous generators. Common LOE detection methods are based on impedance trajectory which makes the system slow and also prone to interpret a stable power swing (SPS as a LOE fault. This paper suggests a new method to detect the LOE based on the measured variables from the DFIG terminal. In this combined method for LOE detection, the rate of change of both the terminal voltage and the output reactive power are utilized and for SPS detection, the fast Fourier transform (FFT analysis of the output instantaneous active power has been used. The performance of the proposed method was evaluated using Matlab/Simulink interface for various power capacities and operating conditions. The results proved the method's quickness, simplicity and security.

  13. Design and analysis of a dead volume control for a solar Stirling engine with induction generator

    International Nuclear Information System (INIS)

    Beltrán-Chacon, Ricardo; Leal-Chavez, Daniel; Sauceda, D.; Pellegrini-Cervantes, Manuel; Borunda, Mónica

    2015-01-01

    In this work, a power generation system dish/Stirling with cavity receiver and an electrical induction generator was simulated. We propose a control system using a variable-dead-volume and analyze its influence on the mechanical performance. A system with a dead volume of 160 cm"3 was designed to control the power and speed of the engine considering annual insolation, mechanical properties of the heater and the limits of frequency and voltage for the systems interconnected to the electricity network. The designed system achieves net efficient solar conversion to electric of 23.38% at an irradiance of 975 W/m"2 and allows an annual increase of 18% of the useful electrical energy compared to a system without control. - Highlights: • Numerical simulation of a nitrogen charged solar Stirling engine for electric power generation. • Design and analysis of a dead volume control for performance increase and power modulation. • Effect of dead space on average working pressure and mass flow rate. • Comparison between dead volume and average pressure control methods. • Impact of Stirling engine control settings on annual generated electric power.

  14. Fast control strategy for stabilising fixed-speed induction-generator-based wind turbines in an islanded distributed system

    DEFF Research Database (Denmark)

    Wei, Mu; Chen, Zhe

    2013-01-01

    Distributed generation systems (DGS) with fixed-speed induction-generator-based wind turbines (FSWT) are sensitive and vulnerable to voltage disturbances and reactive power deficiency. Consequently, the control and protection strategies for such a DGS should be prompt and precise to avoid undesired...

  15. Status of an induction accelerator driven, high-power microwave generator at Livermore

    International Nuclear Information System (INIS)

    Houck, T.L.; Westenskow, G.A.

    1993-01-01

    The authors are testing an enhanced version of the Choppertron, a high-power rf generator which shows great promise of achieving greater than 400 MW of output power at 11.4 GHz with stable phase and amplitude. This version of the Choppertron is driven by a 5-MeV, 1-kA induction accelerator beam. Modifications to the original Choppertron included aggressive suppression of high order modes in the two output structures, lengthening of the modulation section to match for higher beam energy, and improved efficiency. Final results of the original Choppertron experiment, status of the ongoing experiment and planned experiments for the next year are presented. The motivation of the research program at the LLNL Microwave Source Facility is to develop microwave sources which could be suitable drivers for a future TeV linear e + e - collider

  16. Advanced modelling of doubly fed induction generator wind turbine under network disturbance

    DEFF Research Database (Denmark)

    Seman, S.; Iov, Florin; Niiranen, J.

    This paper presents a variable speed wind turbine simulator. The simulator is used for a 2 MW wind turbine transient behavior study during a short-term symmetrical network disturbance. The mechanical part of wind turbine model consists of the rotor aerodynamic model, the wind turbine control...... converter, the model of the main transformer and a simple model of the grid. The simulation results obtained by means of the detailed wind turbine model are compared with the results obtained from a simplified simulator with an analytical model and FEM model of DFIG. The comparison of the results shows...... and the drive train model. The Doubly Fed Induction Generator (DFIG) is represented by an analytical two-axis model with constant lumped parameters and by Finite Element Method (FEM) based model. The model of the DFIG is coupled with the model of the passive crowbar protected and DTC controlled frequency...

  17. Control of Doubly-Fed Induction Generator to Ride-Through Recurring Grid Faults

    DEFF Research Database (Denmark)

    Chen, Wenjie; Xu, Dehong; Zhu, Nan

    2016-01-01

    The wind turbine system (WTS) is required to ride-through recurring grid faults by the new grid codes. Under single grid faults, the fault ride-through (FRT) strategy with rotor-side crowbar is normally used for the doubly-fed induction generator (DFIG) WTS. However, under recurring faults, larger...... transient current and voltage may be produced, and the DFIG may fail to ride-through the second fault even with the rotor-side crowbar. The crowbar can be active again during the voltage recovery, but large electromagnetic torque (EM-torque) fluctuations will be introduced. The reliability of the mechanical...... system will be influenced. In this paper, an FRT strategy for the DFIG WTS to ride-through recurring symmetrical grid faults is investigated. An improved control strategy is introduced and it is applied during the voltage recovery of the grid faults. The decay of the stator natural flux can...

  18. Doubly Fed Induction Generator Wind Turbine Systems Subject to Recurring Symmetrical Grid Faults

    DEFF Research Database (Denmark)

    Chen, Wenjie; Blaabjerg, Frede; Zhu, Nan

    2016-01-01

    New grid codes demand the wind turbine systems to ride through recurring grid faults. In this paper, the performance of the doubly Ffed induction generator (DFIG) wind turbine system under recurring symmetrical grid faults is analyzed. The mathematical model of the DFIG under recurring symmetrical...... grid faults is established. The analysis is based on the DFIG wind turbine system with the typical low-voltage ride-through strategy-with rotor-side crowbar. The stator natural flux produced by the voltage recovery after the first grid fault may be superposed on the stator natural flux produced...... by the second grid fault, so that the transient rotor and stator current and torque fluctuations under the second grid fault may be influenced by the characteristic of the first grid fault, including the voltage dips level and the grid fault angle, as well as the duration between two faults. The mathematical...

  19. Remembering the past and imagining the future: Selective effects of an episodic specificity induction on detail generation.

    Science.gov (United States)

    Madore, Kevin P; Schacter, Daniel L

    2016-01-01

    According to the constructive episodic simulation hypothesis, remembering past experiences and imagining future experiences both rely heavily on episodic memory. However, recent research indicates that nonepisodic processes such as descriptive ability also influence memory and imagination. We recently found that an episodic specificity induction--brief training in recollecting details of past experiences--enhanced detail generation on memory and imagination tasks but not a picture description task and thereby concluded that the induction can dissociate episodic processes involved in remembering the past and imagining the future from those nonepisodic processes involved in description. To evaluate the generality of our previous findings and to examine the role of generative search in producing those findings, we modified our paradigm so that word cues replaced picture cues, and a word comparison task that requires generation of sentences and word definitions replaced picture description. Young adult participants received either a specificity induction or one of two control inductions before completing the memory, imagination, and word comparison tasks. Replicating and extending our previous work, we found that the specificity induction increased detail generation in memory and imagination without having an effect on word comparison. The induction's selective effect on memory and imagination stemmed from an increase in internal (i.e., on-topic and episodic) details and had no effect on external (e.g., off-topic or semantic) details. The results point to the efficacy of the specificity induction for isolating episodic processes involved in remembering the past and imagining the future even when a nonepisodic task requires generative search.

  20. Research on simulated devices for Solar photovoltaic grid-connected generation system

    Directory of Open Access Journals (Sweden)

    quan-zhu Zhang

    2017-01-01

    Full Text Available On the standpoint of energy conservation and emission reduction, one device simulated photovoltaic grid-connected generation system based on SPWM was designed in the paper. And DC/AC inverter could transduce efficiently direct current to alternating current. The MCU(Micro-Control-Unit, in this system could achieve the control method for maximum-power-point and tracking for frequency and phase. Moreover, the MCU could implement PWM (Plus-Width Modulating through programming. The system showed clearly the whole photovoltaic grid-connected generation system using simulated methods and ways.

  1. Vectorial Command of Induction Motor Pumping System Supplied by a Photovoltaic Generator

    Science.gov (United States)

    Makhlouf, Messaoud; Messai, Feyrouz; Benalla, Hocine

    2011-01-01

    With the continuous decrease of the cost of solar cells, there is an increasing interest and needs in photovoltaic (PV) system applications following standard of living improvements. Water pumping system powered by solar-cell generators are one of the most important applications. The fluctuation of solar energy on one hand, and the necessity to optimise available solar energy on the other, it is useful to develop new efficient and flexible modes to control motors that entrain the pump. A vectorial control of an asynchronous motor fed by a photovoltaic system is proposed. This paper investigates a photovoltaic-electro mechanic chain, composed of a PV generator, DC-AC converter, a vector controlled induction motor and centrifugal pump. The PV generator is forced to operate at its maximum power point by using an appropriate search algorithm integrated in the vector control. The optimization is realized without need to adding a DC-DC converter to the chain. The motor supply is also ensured in all insolation conditions. Simulation results show the effectiveness and feasibility of such an approach.

  2. Power Management of Islanded Self-Excited Induction Generator Reinforced by Energy Storage Systems

    Directory of Open Access Journals (Sweden)

    Nachat N. Nasser

    2018-02-01

    Full Text Available Self-Excited Induction Generators (SEIGs, e.g., Small-Scale Embedded wind generation, are increasingly used in electricity distribution networks. The operational stability of stand-alone SEIG is constrained by the local load conditions: stability can be achieved by maintaining the load’s active and reactive power at optimal values. Changes in power demand are dependent on customers’ requirements, and any deviation from the pre-calculated optimum setting will affect a machine’s operating voltage and frequency. This paper presents an investigation of the operation of the SEIG in islanding mode of operation under different load conditions, with the aid of batteries as an energy storage source. In this research a current-controlled voltage-source converter is proposed to regulate the power exchange between a direct current (DC energy storage source and an alternating current (AC grid, the converter’s controller is driven by any variation between machine capability and load demand. In order to prolong the system stability when the battery reaches its operation constraints, it is recommended that an ancillary generator and a dummy local load be embedded in the system. The results show the robustness and operability of the proposed system in the islanding mode of the SEIG under different load conditions.

  3. Centralised control of wind farm with doubly-fed induction generators

    DEFF Research Database (Denmark)

    Hansen, A.D.; Sørensen, Poul Ejnar; Iov, F.

    2005-01-01

    This paper describes the development of an advanced wind farm controller for a wind farm made-up exclusively of doubly-fed generators. The overall aim of such controller is to enable the wind farms to behave as active controllable components in the power system. The attention is mainly drawn...... to the ability of the wind farm control strategy to regulate the wind farm power production to the reference power ordered by the system operators. The performance of the control strategy is assessed and discussed by means of normal operation simulations of a grid connected wind farm....

  4. Mathematic model of three-phase induction machine connected to advanced inverter for traction system for electric trolley

    Directory of Open Access Journals (Sweden)

    LIVIU S. BOCÎI

    2013-06-01

    Full Text Available This paper establishes a mathematical model of induction machine connected to a frequency inverter necessary to adjust the electric motor drive. The mathematical model based on the Park's theory allows the analysis of the whole spectrum (electric car – frequency inverter to drive the electric trolley bus made on ASTRA Bus Arad (Romania. To remove higher order harmonics, the PWM waveform of supply voltage is used, set in the general case. Operating characteristics of electric motor drive are set to sub-nominal frequency (f Bele 2007.Este documento estabelece um modelo matemático de máquina de indução conectado a um inversor de frequência necessário para ajustar o motor de acionamento elétrico. O modelo matemático baseado na Teoria de Park permite a análise de todo o espectro (carro elétrico com inversor de frequência para dirigir o ônibus elétrico feito em ASTRA Bus Arad (Romênia. Para remover harmônicas de ordem mais alta, a forma de onda da tensão de alimentação PWM é utilizado, definido no caso geral. Características de funcionamento do motor de acionamento elétrico são definidas para frequência sub-nominal (f

  5. System Efficiency of a Tap Transformer Based Grid Connection Topology Applied on a Direct Driven Generator for Wind Power

    Directory of Open Access Journals (Sweden)

    Senad Apelfröjd

    2014-01-01

    Full Text Available Results from experiments on a tap transformer based grid connection system for a variable speed vertical axis wind turbine are presented. The tap transformer based system topology consists of a passive diode rectifier, DC-link, IGBT inverter, LCL-filter, and tap transformer. Full range variable speed operation is enabled by using the different step-up ratios of a tap transformer. Simulations using MATLAB/Simulink have been performed in order to study the behavior of the system. A full experimental set up of the system has been used in the laboratory study, where a clone of the on-site generator was driven by an induction motor and the system was connected to a resistive load to better evaluate the performance. Furthermore, the system is run and evaluated for realistic wind speeds and variable speed operation. For a more complete picture of the system performance, a case study using real site Weibull parameters is done, comparing different tap selection options. The results show high system efficiency at nominal power and an increase in overall power output for full tap operation in comparison with the base case, a standard transformer. In addition, the loss distribution at different wind speeds is shown, which highlights the dominant losses at low and high wind speeds. Finally, means for further increasing the overall system efficiency are proposed.

  6. System efficiency of a tap transformer based grid connection topology applied on a direct driven generator for wind power.

    Science.gov (United States)

    Apelfröjd, Senad; Eriksson, Sandra

    2014-01-01

    Results from experiments on a tap transformer based grid connection system for a variable speed vertical axis wind turbine are presented. The tap transformer based system topology consists of a passive diode rectifier, DC-link, IGBT inverter, LCL-filter, and tap transformer. Full range variable speed operation is enabled by using the different step-up ratios of a tap transformer. Simulations using MATLAB/Simulink have been performed in order to study the behavior of the system. A full experimental set up of the system has been used in the laboratory study, where a clone of the on-site generator was driven by an induction motor and the system was connected to a resistive load to better evaluate the performance. Furthermore, the system is run and evaluated for realistic wind speeds and variable speed operation. For a more complete picture of the system performance, a case study using real site Weibull parameters is done, comparing different tap selection options. The results show high system efficiency at nominal power and an increase in overall power output for full tap operation in comparison with the base case, a standard transformer. In addition, the loss distribution at different wind speeds is shown, which highlights the dominant losses at low and high wind speeds. Finally, means for further increasing the overall system efficiency are proposed.

  7. System Efficiency of a Tap Transformer Based Grid Connection Topology Applied on a Direct Driven Generator for Wind Power

    Science.gov (United States)

    2014-01-01

    Results from experiments on a tap transformer based grid connection system for a variable speed vertical axis wind turbine are presented. The tap transformer based system topology consists of a passive diode rectifier, DC-link, IGBT inverter, LCL-filter, and tap transformer. Full range variable speed operation is enabled by using the different step-up ratios of a tap transformer. Simulations using MATLAB/Simulink have been performed in order to study the behavior of the system. A full experimental set up of the system has been used in the laboratory study, where a clone of the on-site generator was driven by an induction motor and the system was connected to a resistive load to better evaluate the performance. Furthermore, the system is run and evaluated for realistic wind speeds and variable speed operation. For a more complete picture of the system performance, a case study using real site Weibull parameters is done, comparing different tap selection options. The results show high system efficiency at nominal power and an increase in overall power output for full tap operation in comparison with the base case, a standard transformer. In addition, the loss distribution at different wind speeds is shown, which highlights the dominant losses at low and high wind speeds. Finally, means for further increasing the overall system efficiency are proposed. PMID:25258733

  8. The challenges of connecting generation to distribution systems: a utility perspective

    International Nuclear Information System (INIS)

    Kropp, F.

    2004-01-01

    'Full text:' This presentation discusses the technical, financial and regulatory barriers to connecting generation to Distribution Systems in Ontario. Case studies will be used to provide examples of the operational and technical challenges that impact the utility as well as a discussion on the site-specific advantages and disadvantages (to the utility) of the generation connections. These studies will include discussions on the problems and lessons learned with respect to the overall project implementation and the contractual agreements. The case studies will be complemented by an explanation of the financial constraints (both short term and long term) associated with the connections, and the regulatory issues that impact the financial recovery models including net and gross load billing. (author)

  9. Online Energy Management System for Distributed Generators in a Grid-Connected Microgrid

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Graells, Moises

    2015-01-01

    A microgrid is an energy subsystem composed of generation units, energy storage, and loads that requires power management in order to supply the load properly according to defined objectives. This paper proposes an online energy management system for a storage based grid-connected microgrid...

  10. Three-Phase Grid-Connected of Photovoltaic Generator Using Nonlinear Control

    DEFF Research Database (Denmark)

    Yahya, A.; El Fadil, H.; Guerrero, Josep M.

    2014-01-01

    This paper proposes a nonlinear control methodology for three phase grid connected of PV generator. It consists of a PV arrays; a voltage source inverter, a grid filter and an electric grid. The controller objectives are threefold: i) ensuring the Maximum power point tracking (MPPT) in the side...... stability analysis and simulation results that the proposed controller meets all the objectives....

  11. Economic Power Dispatch of Distributed Generators in a Grid-Connected Microgrid

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Andrade, Fabio

    2015-01-01

    Grid-connected microgrids with storage systems are reliable configurations for critical loads which can not tolerate interruptions of energy supply. In such cases, some of the energy resources should be scheduled in order to coordinate optimally the power generation according to a defined objective...

  12. Connection and Commitment: Exploring the Generation and Experience of Emotion in a Participatory Drama

    Science.gov (United States)

    Dunn, Julie; Bundy, Penny; Stinson, Madonna

    2015-01-01

    Emotion is a complex and important aspect of participatory drama experience. This is because drama work of this kind provokes emotional responses to both actual and dramatic worlds. This paper identifies two key features of participatory drama that influence the generation and experience of emotion: commitment and connection. These features are…

  13. Simplified model of wind turbines with doubly-fed induction generator

    Energy Technology Data Exchange (ETDEWEB)

    Timbus, Adrian; Korba, Petr [ABB Corporate Research, Baden-Daettwil (Switzerland); Vilhunen, Antti; Pepe, Giuseppe; Seman, Slavomir; Niiranen, Jouko [ABB Oy, Helsinki (Finland)

    2011-07-01

    With an ever increasing pace of wind power installations around the world, the necessity of studying the functionality of the power system with intermittent generation becomes a critical necessity. Power system studies have been carried out by different organizations, using mainly generic models of turbines available in most utilized software tools such as PSS/E, PowerFactory, PSLF, etc. Very often the system operators ask for models of turbines which represent a specific vendor, hence vendor specific models become also available in these tools. These are necessary to evaluate a realistic response of the grid when a particular technology is used for the wind turbines. This paper elaborates on the development of a simplified model of a wind turbine equipped with Doubly-Fed Induction Generator. The model is meant to be suitable for power system studies and should reflect the concept provided by ABB. This model comprises a series of state machines which reflect the functionality of the turbine from start-up until shut-down due to high wind speeds. In addition, attention and efforts were focused to provide the right functionality during low voltage values, - the so called low voltage ride through feature - and to support the grid after voltage sag. (orig.)

  14. Software for evaluating magnetic induction field generated by power lines: implementation of a new algorithm

    International Nuclear Information System (INIS)

    Comelli, M.; Benes, M.; Bampo, A.; Villalta, R.

    2006-01-01

    The Regional Environment Protection Agency of Friuli Venezia Giulia (A.R.P.A. F.V.G., Italy) has performed an analysis on existing software designed to calculate magnetic induction field generated by power lines. As far as the agency requirements are concerned the tested programs display some difficulties in the immediate processing of electrical and geometrical data supplied by plant owners, and in certain cases turn out to be inadequate in representing complex configurations of power lines. Furthermore, none of them is preset for cyclic calculus to determine the time evolution of induction in a certain exposure area. Finally, the output data are not immediately importable by ArcView, the G.I.S. used by A.R.P.A. F.V.G., and it is not always possible to implement the territory orography to determine the field at specified heights above the ground. P.h.i.d.e.l., an innovative software, tackles and works out al l the above mentioned problems. The power line wires interested in its implementation are represented by poly lines, and the field is analytically calculated, with no further approximation, not even when more power lines are concerned. Therefore, the obtained results, when compared with those of other programs, are the closest to experimental measurements. The output data can be employed both in G.I.S. and Excel environments, allowing the immediate overlaying of digital cartography and the determining of the 3 and 10 μT bands, in compliance with the Italian Decree of the President of the Council of Ministers of 8 July 2003. (authors)

  15. Improvement of small-signal stability of power system by controlling doubly fed induction generators of a large-capacity wind farm

    Directory of Open Access Journals (Sweden)

    Tomohiro Adachi

    2016-01-01

    Full Text Available Many wind turbine generations have been installed into power systems around the world, where in recent years doubly fed induction generator (DFIG attracts a lot of attentions because of its efficiency and controllability. However, the DFIG is connected to the power system through inverters and originally does not have an ability to release the kinetic energy of the rotor or resorb the surplus power of the power system as the kinetic energy. Therefore, it has not been made clear how the DFIGs have an influence on small-signal stability in power systems. In this paper, we propose a control scheme of the DFIG and analyse its effect on the small-signal stability of the power system by eigenvalue calculations and time-domain simulations.

  16. Looking Deeper Into Hydrologic Connectivity and Streamflow Generation: A Groundwater Hydrologist's Perspective.

    Science.gov (United States)

    Gardner, W. P.

    2016-12-01

    In this presentation the definition of hydraulic connection will be explored with a focus on the role of deep groundwater in streamflow generation and its time and space limits. Regional groundwater flow paths can be important sources of baseflow and potentially event response in surface water systems. This deep groundwater discharge plays an important role in determining how the watershed responds to climatic forcing, whether watersheds are a carbon source or sink and can be significant for watershed geochemistry and nutrient loading. These flow paths potentially "connect" to surface water systems and saturated soil zones at large distances, and over long time scales. However, these flow paths are challenging to detect, especially with hydraulic techniques. Here we will discuss some of the basic physical processes that affect the hydraulic signal along a groundwater flow path and their implications for the definition of hydrologic connection. Methods of measuring hydraulic connection using groundwater head response and their application in detecting regional groundwater discharge will be discussed. Environmental tracers are also a powerful method for identifying connected flowpaths in groundwater systems, and are commonly used to determine flow connection and flow rates in groundwater studies. Isotopic tracer methods for detecting deep, regional flow paths in watersheds will be discussed, along with observations of deep groundwater discharge in shallow alluvial systems around the world. The goal of this talk is to discuss hydraulic and hydrologic connection from a groundwater hydrologist's perspective, spark conversation on the meaning of hydrologic connection, the processes which govern hydraulic response and methods to measure flow connections and flux.

  17. Modeling, analysis, control and design application guidelines of Doubly Fed Induction Generator (DFIG) for wind power applications

    Science.gov (United States)

    Masaud, Tarek

    Double Fed Induction Generators (DFIG) has been widely used for the past two decades in large wind farms. However, there are many open-ended problems yet to be solved before they can be implemented in some specific applications. This dissertation deals with the general analysis, modeling, control and applications of the DFIG for large wind farm applications. A detailed "d-q" model of DFIG along with other applications is simulated using the MATLAB/Simulink platform. The simulation results have been discussed in detail in both sub-synchronous and super-synchronous mode of operation. An improved vector control strategy based on the rotor flux oriented vector control has been proposed to control the active power output of the DFIG. The new vector control strategy is compared with the stator flux oriented vector control which is commonly used. It is observed that the new improved vector control method provides a better active power tracking accuracy compare with the stator flux oriented vector control. The behavior of the DFIG -based wind farm under the various grid disturbances is also studied in this dissertation. The implementation of the Flexible AC Transmission System devices (FACTS) to overcome the voltage stability issue for such applications is investigated. The study includes the implementation of both a static synchronous compensator (STATCOM), and the static VAR compensator (SVC) as dynamic reactive power compensators at the point of common coupling to support DFIG-based wind farm during disturbances. Integrating FACTS protect the grid connected DFIG-based wind farm from going offline during and after the disturbances. It is found that the both devices improve the transient performance and therefore helps the wind turbine generator system to remain in service during grid faults. A comparison between the performance of the two devices in terms of the amount of reactive power injected, time response and the application cost has been discussed in this

  18. Induction of antiproliferative connective tissue growth factor expression in Wilms' tumor cells by sphingosine-1-phosphate receptor 2.

    Science.gov (United States)

    Li, Mei-Hong; Sanchez, Teresa; Pappalardo, Anna; Lynch, Kevin R; Hla, Timothy; Ferrer, Fernando

    2008-10-01

    Connective tissue growth factor (CTGF), a member of the CCN family of secreted matricellular proteins, regulates fibrosis, angiogenesis, cell proliferation, apoptosis, tumor growth, and metastasis. However, the role of CTGF and its regulation mechanism in Wilms' tumor remains largely unknown. We found that the bioactive lipid sphingosine-1-phosphate (S1P) induced CTGF expression in a concentration- and time-dependent manner in a Wilms' tumor cell line (WiT49), whereas FTY720-phosphate, an S1P analogue that binds all S1P receptors except S1P2, did not. Further, the specific S1P2 antagonist JTE-013 completely inhibited S1P-induced CTGF expression, whereas the S1P1 antagonist VPC44116 did not, indicating that this effect was mediated by S1P2. This was confirmed by adenoviral transduction of S1P2 in WiT49 cells, which showed that overexpression of S1P2 increased the expression of CTGF. Induction of CTGF by S1P was sensitive to ROCK inhibitor Y-27632 and c-Jun NH2-terminal kinase inhibitor SP600125, suggesting the requirement of RhoA/ROCK and c-Jun NH2-terminal kinase pathways for S1P-induced CTGF expression. Interestingly, the expression levels of CTGF were decreased in 8 of 10 Wilms' tumor tissues compared with matched normal tissues by quantitative real-time PCR and Western blot analysis. In vitro, human recombinant CTGF significantly inhibited the proliferation of WiT49 cells. In addition, overexpression of CTGF resulted in significant inhibition of WiT49 cell growth. Taken together, these data suggest that CTGF protein induced by S1P2 might act as a growth inhibitor in Wilms' tumor.

  19. Decentralized electricity generation by using photovoltaic grid-connected solar system

    International Nuclear Information System (INIS)

    Tyutyundziev, N.; Vitanov, P.; Radkov, R.; Grottke, M.

    2006-01-01

    AcadPV is the first demonstration installation connected permanently to LV grid in Sofia, Bulgaria aiming at assessment of PV efficiencies and cost-effectiveness. A thorough analysis has been carried out in order to select PV system site, supporting construction design and orientation. The PV generator is divided to 3 PV subfields equipped by 3 SUNPOWER inverters connected to 3 separated phases of the grid. The performance of 10kWp PV system has been evaluated during the first year of operation and compared to PV simulation software results

  20. Effects of voltage unbalance and system harmonics on the performance of doubly fed induction wind generators

    Science.gov (United States)

    Kiani, Morgan Mozhgan

    Inherent difficulties in management of electric power in the presence of an increasing demand for more energy, non-conventional loads such as digital appliances, and non-sustainable imported fossil fuels has initiated a multi-folded effort by many countries to restructure the way electric energy is generated, dispatched, and consumed. Smart power grid is the manifestation of many technologies that would eventually transforms the existing power grid into a more flexible, fault resilient, and intelligent system. Integration of distributed renewable energy sources plays a central role in successful implementation of this transformation. Among the renewable options, wind energy harvesting offers superior engineering and economical incentives with minimal environmental impacts. Doubly fed induction generators (DFIG) have turned into a serious contender for wind energy generators due to their flexibility in control of active and reactive power with minimal silicon loss. Significant presence of voltage unbalance and system harmonics in finite inertia transmission lines can potentially undermine the reliability of these wind generators. The present dissertation has investigated the impacts of system unbalances and harmonics on the performance of the DFIG. Our investigation indicates that these effects can result in an undesirable undulation in the rotor shaft which can potentially invoke mechanical resonance, thereby causing catastrophic damages to the installations and the power grid. In order to remedy the above issue, a control solution for real time monitoring of the system unbalance and optimal excitation of the three phase rotor currents in a DFIG is offered. The optimal rotor currents will create appropriate components of the magneto-motive force in the airgap that will actively compensate the undesirable magnetic field originated by the stator windings. Due to the iterative nature of the optimization procedure, field reconstruction method has been incorporated

  1. Sizing modelling and simulation of PV generation system feeding a 6 MW induction motor dedicated to pumping applications

    Directory of Open Access Journals (Sweden)

    Samir HADJERI

    2017-06-01

    Full Text Available This paper proposes an autonomous photovoltaic (PV pumping system for rural/remote applications especially in the large desert in northern Africa where the sun radiation is abundant. Since PV generators exhibit nonlinear I-V characteristics and their maximum power point varies with solar radiation. For this reason, the MPPT controller is used to optimize the solar energy conversion by guaranteeing fast maximum power point tracking (MPPT. This feature has an essential role in dynamic response and efficiency of the photovoltaic system, thus it maximizes the amount of extracted natural gas to be conveyed to another site for an ulterior utilization. Here a robust maximum power point tracker (MPPT using incremental conductance algorithm is applied to the duty cycle value of the DC-DC converter which acts directly on the drive speed. A DC/DC boost is used to enhance voltage up to the favourite level and the SVPWM inverter connects it to a powerful induction motor for a pumping of natural gas application, these systems are at the heart of many industrial sectors such as the oil industry, the production of thermal and nuclear energy etc. An understanding of how these systems operate is essential to increase their performance and reduce their operating costs. Furthermore, three phase voltage-fed PWM inverters are recently showing growing popularity for multi-megawatt industrial drive applications, the main purpose of these topologies is to provide a three-phase voltage source, where the amplitude, phase, and frequency of the voltages should always be controllable. The model of a three-phase voltage source inverter is modelled and discussed based on space vector modulation theory. Simulation results are obtained using MATLAB/Simulink environment for effectiveness of the proposed system.

  2. Novel scheme for enhancement of fault ride-through capability of doubly fed induction generator based wind farms

    International Nuclear Information System (INIS)

    Vinothkumar, K.; Selvan, M.P.

    2011-01-01

    Research highlights: → Proposed Fault ride-through (FRT) scheme for DFIG is aimed at energy conservation. → The input mechanical energy is stored during fault and utilized at fault clearance. → Enhanced Rotor speed stability of DFIG. → Reduced Reactive power requirement and rapid voltage recovery at fault clearance. → Improved post fault performance of DFIG at fault clearance. -- Abstract: Enhancement of fault ride-through (FRT) capability and subsequent improvement of rotor speed stability of wind farms equipped with doubly fed induction generator (DFIG) is the objective of this paper. The objective is achieved by employing a novel FRT scheme with suitable control strategy. The proposed FRT scheme, which is connected between the rotor circuit and dc link capacitor in parallel with Rotor Side Converter, consists of an uncontrolled rectifier, two sets of IGBT switches, a diode and an inductor. In this scheme, the input mechanical energy of the wind turbine during grid fault is stored and utilized at the moment of fault clearance, instead of being dissipated in the resistors of the crowbar circuit as in the existing FRT schemes. Consequently, torque balance between the electrical and mechanical quantities is achieved and hence the rotor speed deviation and electromagnetic torque fluctuations are reduced. This results in reduced reactive power requirement and rapid reestablishment of terminal voltage on fault clearance. Furthermore, the stored electromagnetic energy in the inductor is transferred into the dc link capacitor on fault clearance and hence the grid side converter is relieved from charging the dc link capacitor, which is very crucial at this moment, and this converter can be utilized to its full capacity for rapid restoration of terminal voltage and normal operation of DFIG. Extensive simulation study carried out employing PSCAD/EMTDC software vividly demonstrates the potential capabilities of the proposed scheme in enhancing the performance of

  3. Novel scheme for enhancement of fault ride-through capability of doubly fed induction generator based wind farms

    Energy Technology Data Exchange (ETDEWEB)

    Vinothkumar, K. [Department of Electrical and Electronics Engineering, National Institute of Technology, Tiruchirappalli, Tamilnadu 620015 (India); Selvan, M.P., E-mail: selvanmp@nitt.ed [Department of Electrical and Electronics Engineering, National Institute of Technology, Tiruchirappalli, Tamilnadu 620015 (India)

    2011-07-15

    Research highlights: {yields} Proposed Fault ride-through (FRT) scheme for DFIG is aimed at energy conservation. {yields} The input mechanical energy is stored during fault and utilized at fault clearance. {yields} Enhanced Rotor speed stability of DFIG. {yields} Reduced Reactive power requirement and rapid voltage recovery at fault clearance. {yields} Improved post fault performance of DFIG at fault clearance. -- Abstract: Enhancement of fault ride-through (FRT) capability and subsequent improvement of rotor speed stability of wind farms equipped with doubly fed induction generator (DFIG) is the objective of this paper. The objective is achieved by employing a novel FRT scheme with suitable control strategy. The proposed FRT scheme, which is connected between the rotor circuit and dc link capacitor in parallel with Rotor Side Converter, consists of an uncontrolled rectifier, two sets of IGBT switches, a diode and an inductor. In this scheme, the input mechanical energy of the wind turbine during grid fault is stored and utilized at the moment of fault clearance, instead of being dissipated in the resistors of the crowbar circuit as in the existing FRT schemes. Consequently, torque balance between the electrical and mechanical quantities is achieved and hence the rotor speed deviation and electromagnetic torque fluctuations are reduced. This results in reduced reactive power requirement and rapid reestablishment of terminal voltage on fault clearance. Furthermore, the stored electromagnetic energy in the inductor is transferred into the dc link capacitor on fault clearance and hence the grid side converter is relieved from charging the dc link capacitor, which is very crucial at this moment, and this converter can be utilized to its full capacity for rapid restoration of terminal voltage and normal operation of DFIG. Extensive simulation study carried out employing PSCAD/EMTDC software vividly demonstrates the potential capabilities of the proposed scheme in

  4. Analysis and control of induction generator supplying stand-alone AC loads employing a Matrix Converter

    Directory of Open Access Journals (Sweden)

    Sumedha Mahajan

    2017-04-01

    Full Text Available This paper proposes a Capacitor Excited Induction Generator (CEIG-Matrix Converter (MC system for feeding stand-alone AC loads. The variable output voltage magnitude and frequency from CEIG is converted into a constant voltage magnitude and frequency at the load terminals by controlling MC using Space Vector Modulation (SVM technique. This single-stage MC is turned up as a good alternative for the proposed system against commonly used AC/DC/AC two stage power converters. The configuration and implementation of the closed-loop control scheme employing dSPACE 1103 real time controller have been fully described in the paper. The proposed closed-loop controller regulates the AC load voltage irrespective of changes in the prime mover speed and load. A method for predetermining the steady-state performance of the proposed system has been developed and described with relevant analytical expressions. The effectiveness of the proposed system is exemplified through simulation results for various operating conditions. The proposed control technique is further validated using an experimental setup developed in the laboratory.

  5. Design of an Inductive Adder for the FCC injection kicker pulse generator

    Science.gov (United States)

    Woog, D.; Barnes, M. J.; Ducimetière, L.; Holma, J.; Kramer, T.

    2017-07-01

    The injection system for a 100 TeV centre-of-mass collider is an important part of the Future Circular Collider (FCC) study. Due to issues with conventional kicker systems, such as self-triggering and long term availability of thyratrons and limitations of HV-cables, innovative design changes are planned for the FCC injection kicker pulse generator. An inductive adder (IA) based on semiconductor (SC) switches is a promising technology for kicker systems. Its modular design, and the possibility of an active ripple suppression are significant advantages. Since the IA is a complex device, with multiple components whose characteristics are important, a detailed design study and construction of a prototype is necessary. This paper summarizes the system requirements and constraints, and describes the main components and design challenges of the prototype IA. It outlines the results from simulations and measurements on different magnetic core materials as well as on SC switches. The paper concludes on the design choices and progress for the prototype to be built at CERN.

  6. Dependence of Initial Oxygen Concentration on Ozone Yield Using Inductive Energy Storage System Pulsed Power Generator

    Science.gov (United States)

    Go, Tomio; Tanaka, Yasushi; Yamazaki, Nobuyuki; Mukaigawa, Seiji; Takaki, Koichi; Fujiwara, Tamiya

    Dependence of initial oxygen concentration on ozone yield using streamer discharge reactor driven by an inductive energy storage system pulsed power generator is described in this paper. Fast recovery type diodes were employed as semiconductor opening switch to interrupt a circuit current within 100 ns. This rapid current change produced high-voltage short pulse between a secondary energy storage inductor. The repetitive high-voltage short pulse was applied to a 1 mm diameter center wire electrode placed in a cylindrical pulse corona reactor. The streamer discharge successfully occurred between the center wire electrode and an outer cylinder ground electrode of 2 cm inner diameter. The ozone was produced with the streamer discharge and increased with increasing pulse repetition rate. The ozone yield changed in proportion to initial oxygen concentration contained in the injected gas mixture at 800 ns forward pumping time of the current. However, the decrease of the ozone yield by decreasing oxygen concentration in the gas mixture at 180 ns forward pumping time of the current was lower than the decrease at 800 ns forward pumping time of the current. This dependence of the initial oxygen concentration on ozone yield at 180 ns forward pumping time is similar to that of dielectric barrier discharge reactor.

  7. Transient Performance Improvement of Wind Turbines with Doubly Fed Induction Generators Using Active Damping Control Strategy

    Directory of Open Access Journals (Sweden)

    Saeed Soleymani

    2016-01-01

    Full Text Available This paper Analytically investigates the effects of system and controller parameters and operating conditions on the dynamic and transient behavior of wind turbines (WTs with doubly-fed induction generators (DFIGs under voltage dips and wind speed fluctuations. Also, it deals with the design considerations regarding rotor and speed controllers. The poorly damped electrical and mechanical modes of the system are identified, and the effects of system parameters, and speed/rotor controllers on these modes are investigated by modal and sensitivity analyses. The results of theoretical studies are verified by time domain simulations. It is found that the dynamic behavior of the DFIG-based WT under voltage dips is strongly affected by the stator dynamics. Further, it is shown that the closed loop bandwidth of the rotor current control, rotor current damping, DFIG power factor and the rotor back-emf voltages have high impact on the stator modes and consequently on the DFIG dynamic behavior. Moreover, it is shown that the dynamic behavior of DFIG-based WT under wind speed fluctuation is significantly dependent on the bandwidth and damping of speed control loop.

  8. Detailed Transients Simulation of a Doubly Fed Induction Generator Wind Turbine System with the EMTP-Type OVNI Simulator

    OpenAIRE

    Lukić Armstrong, Mažana; R. Martí, José; Kundur, Prabha

    2017-01-01

    Doubly fed induction generator wind turbines are increasingly used in new wind turbine installations all over the world. Growing concerns about the impact of a large number of these generators on transient and voltage stability of power system networks has led engineers to revisit modelling and simulation practices used for system stability analyses. In this paper, the latest advancements in design of the general purpose power system simulator OVNI developed at the University o...

  9. Identification of Synchronous Generator Electric Parameters Connected to the Distribution Grid

    Directory of Open Access Journals (Sweden)

    Frolov M. Yu.

    2017-04-01

    Full Text Available According to modern trends, the power grids with distributed generation will have an open system architecture. It means that active consumers, owners of distributed power units, including mobile units, must have free access to the grid, like when using internet, so it is necessary to have plug and play technologies. Thanks to them, the system will be able to identify the unit type and the unit parameters. Therefore, the main aim of research, described in the paper, was to develop and research a new method of electric parameters identification of synchronous generator. The main feature of the proposed method is that parameter identification is performed while the generator to the grid, so it fits in the technological process of operation of the machine and does not influence on the connection time of the machine. For the implementation of the method, it is not necessary to create dangerous operation modes for the machine or to have additional expensive equipment and it can be used for salient pole machines and round rotor machines. The parameter identification accuracy can be achieved by more accurate account of electromechanical transient process, and making of overdetermined system with many more numbers of equations. Parameter identification will be made with each generator connection to the grid. Comparing data obtained from each connection, the middle values can be find by numerical method, and thus, each subsequent identification will accurate the machine parameters.

  10. A generative modeling approach to connectivity-Electrical conduction in vascular networks

    DEFF Research Database (Denmark)

    Hald, Bjørn Olav

    2016-01-01

    The physiology of biological structures is inherently dynamic and emerges from the interaction and assembly of large collections of small entities. The extent of coupled entities complicates modeling and increases computational load. Here, microvascular networks are used to present a novel...... to synchronize vessel tone across the vast distances within a network. We hypothesize that electrical conduction capacity is delimited by the size of vascular structures and connectivity of the network. Generation and simulation of series of dynamical models of electrical spread within vascular networks...... of different size and composition showed that (1) Conduction is enhanced in models harboring long and thin endothelial cells that couple preferentially along the longitudinal axis. (2) Conduction across a branch point depends on endothelial connectivity between branches. (3) Low connectivity sub...

  11. Characterization methods of nano-patterned surfaces generated by induction heating assisted injection molding

    DEFF Research Database (Denmark)

    Tang, Peter Torben; Ravn, Christian; Menotti, Stefano

    2015-01-01

    An induction heating-assisted injection molding (IHAIM) process developed by the authors is used to replicate surfaces containing random nano-patterns. The injection molding setup is developed so that an induction heating system rapidly heats the cavity wall at rates of up to 10◦C/s. In order...

  12. Connecting the Members of Generation Y to Destination Brands: A Case Study of the CUBIS Project

    Directory of Open Access Journals (Sweden)

    Ralf Bochert

    2017-07-01

    Full Text Available There is direct correlation between building powerful destination brands and the degree to which tourists and locals share the brands values. The massive penetration of the active population by Generation Y has generated a major shift in tourism marketing, based on the profile of this cohort. The members of Generation Y are very different from previous generations. The so-called “digital natives” share high technological proficiency; they like to share their skills; they are disloyal consumers; and they are affected by trends. In order to connect with members of Generation Y and to actively involve them into the life of tourist destinations, viral, participative, interactive, networked and versatile marketing techniques should be employed. This article introduces the Intelligent Solution for Brand Culturalization (CUBIS Project, which is a collaborative research initiative that offers to Destination Management Organizations an innovative idea of how to connect the members of Generation Y with destination brands using information and communication technologies (ICT. The CUBIS Project aims to create emotional attachment with the brand values and supports the adoption of the brand by young locals and tourists. The CUBIS idea is flexible and highly adaptable to other destinations. The article uses exploratory qualitative research in the form of a case study.

  13. Toward Rigorous Parameterization of Underconstrained Neural Network Models Through Interactive Visualization and Steering of Connectivity Generation

    Directory of Open Access Journals (Sweden)

    Christian Nowke

    2018-06-01

    Full Text Available Simulation models in many scientific fields can have non-unique solutions or unique solutions which can be difficult to find. Moreover, in evolving systems, unique final state solutions can be reached by multiple different trajectories. Neuroscience is no exception. Often, neural network models are subject to parameter fitting to obtain desirable output comparable to experimental data. Parameter fitting without sufficient constraints and a systematic exploration of the possible solution space can lead to conclusions valid only around local minima or around non-minima. To address this issue, we have developed an interactive tool for visualizing and steering parameters in neural network simulation models. In this work, we focus particularly on connectivity generation, since finding suitable connectivity configurations for neural network models constitutes a complex parameter search scenario. The development of the tool has been guided by several use cases—the tool allows researchers to steer the parameters of the connectivity generation during the simulation, thus quickly growing networks composed of multiple populations with a targeted mean activity. The flexibility of the software allows scientists to explore other connectivity and neuron variables apart from the ones presented as use cases. With this tool, we enable an interactive exploration of parameter spaces and a better understanding of neural network models and grapple with the crucial problem of non-unique network solutions and trajectories. In addition, we observe a reduction in turn around times for the assessment of these models, due to interactive visualization while the simulation is computed.

  14. Power Quality Improvement in a Cascaded Multilevel Inverter Interfaced Grid Connected System Using a Modified Inductive–Capacitive–Inductive Filter with Reduced Power Loss and Improved Harmonic Attenuation

    Directory of Open Access Journals (Sweden)

    Meenakshi Jayaraman

    2017-11-01

    Full Text Available Recently, multilevel inverters are more researched due to the advantages they offer over conventional voltage source inverters in grid connected applications. Passive filters are connected at the output of these inverters to produce sinusoidal waveforms with reduced harmonics and to satisfy grid interconnection standard requirements. This work proposes a new passive filter topology for a pulse width modulated five-level cascaded inverter interfaced grid connected system. The proposed passive filter inserts an additional resistance-capacitance branch in parallel to the filter capacitor of the traditional inductive–capacitive–inductive filter in addition to a resistance in series with it to reduce damping power loss. It can attenuate the switching frequency harmonic current components much better than the traditional filter while maintaining the same overall inductance, reduced capacitance and resistance values. The basic parameter design procedure and an approach to discover the parameters of the proposed filter is introduced. Further, a novel methodology using Particle Swarm Optimization (PSO is recommended to guarantee minimum damping loss while ensuring reduced peak during resonance. In addition, PSO algorithm is newly employed in this work to maximize harmonic attenuation in and around the switching frequency on the premise of allowable values of filter inductance and capacitance. A comparative discussion considering traditional passive filters and the proposed filter is presented and evaluated through experiments conducted on a 110 V, 1 kW five-level grid connected inverter. The modulation algorithm for the multilevel inverter is implemented using a SPARTAN 6-XC6SLX25 Field Programmable Gate Array (FPGA processor. The analysis shows that the proposed filter not only provides decreased damping power loss but also is capable of providing considerable harmonic ripple reduction in the high frequency band, improved output waveforms and lesser

  15. The many-body content of quantum gauge theories and its connection to mass generation mechanisms

    International Nuclear Information System (INIS)

    Natoli, C.R.; Palumbo, F.

    1985-01-01

    The aim of the paper is to get more knowledge about many-body systems and their properties, about many-body content of quantum gauge theories and its connection with mass generation mechanisms. The way to achieve this is to perform the galilean limit of the relativistic theory by sending the speed of light c to infinity. This limiting process exposes the low energy behaviour of the relativistic theory

  16. RMS Current of a Photovoltaic Generator in Grid-Connected PV Systems: Definition and Application

    Directory of Open Access Journals (Sweden)

    P. J. Pérez

    2008-01-01

    Full Text Available This paper includes a definition of a new and original concept in the photovoltaic field, RMS current of a photovoltaic generator for grid-connected systems. The RMS current is very useful for calculating energy losses in cables used in a PV generator. As well, a current factor has been defined in order to simplify RMS current calculation. This factor provides an immediate (quick and easy calculation method for the RMS current that does not depend on the case particular conditions (orientation, location, etc.. RMS current and current factor values have been calculated for different locations and modules.

  17. Research on grid connection control technology of double fed wind generator

    Science.gov (United States)

    Ling, Li

    2017-01-01

    The composition and working principle of variable speed constant frequency doubly fed wind power generation system is discussed in this thesis. On the basis of theoretical analysis and control on the modeling, the doubly fed wind power generation simulation control system is designed based on a TMS320F2407 digital signal processor (DSP), and has done a large amount of experimental research, which mainly include, variable speed constant frequency, constant pressure, Grid connected control experiment. The running results show that the design of simulation control system is reasonable and can meet the need of experimental research.

  18. Impact of Rural Grid-Connected Photovoltaic Generation Systems on Power Quality

    Directory of Open Access Journals (Sweden)

    Rita Pinto

    2016-09-01

    Full Text Available Photovoltaic (PV generation systems have been increasingly used to generate electricity from renewable sources, attracting a growing interest. Recently, grid connected PV micro-generation facilities in individual homes have increased due to governmental policies as well as greater attention by industry. As low voltage (LV distribution systems were built to make energy flow in one direction, the power feed-in of PV generation in rural low-voltage grids can influence power quality (PQ as well as facility operation and reliability. This paper presents results on PQ analysis of a real PV generation facility connected to a rural low-voltage grid. Voltage fluctuations and voltage harmonic contents were observed. Statistical analysis shows a negative impact on PQ produced by this PV facility and also that only a small fraction of the energy available during a sunny day is converted, provoking losses of revenue and forcing the converter to work in an undesirable operating mode. We discuss the disturbances imposed upon the grid and their outcome regarding technical and economic viability of the PV system, as well as possible solutions. A low-voltage grid strengthening has been suggested and implemented. After that a new PQ analysis shows an improvement in the impact upon PQ, making this facility economically viable.

  19. Real-time simulation of a Doubly-Fed Induction Generator based wind power system on eMEGASimRTM Real-Time Digital Simulator

    Science.gov (United States)

    Boakye-Boateng, Nasir Abdulai

    The growing demand for wind power integration into the generation mix prompts the need to subject these systems to stringent performance requirements. This study sought to identify the required tools and procedures needed to perform real-time simulation studies of Doubly-Fed Induction Generator (DFIG) based wind generation systems as basis for performing more practical tests of reliability and performance for both grid-connected and islanded wind generation systems. The author focused on developing a platform for wind generation studies and in addition, the author tested the performance of two DFIG models on the platform real-time simulation model; an average SimpowerSystemsRTM DFIG wind turbine, and a detailed DFIG based wind turbine using ARTEMiSRTM components. The platform model implemented here consists of a high voltage transmission system with four integrated wind farm models consisting in total of 65 DFIG based wind turbines and it was developed and tested on OPAL-RT's eMEGASimRTM Real-Time Digital Simulator.

  20. Studies on battery storage requirement of PV fed wind-driven induction generators

    International Nuclear Information System (INIS)

    Rajan Singaravel, M.M.; Arul Daniel, S.

    2013-01-01

    Highlights: ► Sizing of battery storage for PV fed wind-driven IG system is taken up. ► Battery storage is also used to supply reactive power for wind-driven IG. ► Computation of LPSP by incorporating uncertainties of irradiation and wind speed. ► Sizing of hybrid power system components to ensure zero LPSP. ► Calculated storage size satisfied the constraints and improves battery life. - Abstract: Hybrid stand-alone renewable energy systems based on wind–solar resources are considered to be economically better and reliable than stand-alone systems with a single source. An isolated hybrid wind–solar system has been considered in this work, where the storage (battery bank) is necessary to supply the required reactive power for a wind-driven induction generator (IG) during the absence of power from a photovoltaic (PV) array. In such a scheme, to ensure zero Loss of Power Supply Probability (LPSP) and to improve battery bank life, a sizing procedure has been proposed with the incorporation of uncertainties in wind-speed and solar-irradiation level at the site of erection of the plant. Based on the proposed procedure, the size of hybrid power system components and storage capacity are determined. Storage capacity has been calculated for two different requirements. The first requirement of storage capacity is common to any hybrid scheme, which is; to supply both real and reactive power in the absence of wind and solar sources. The second requirement is to supply reactive power alone for the IG during the absence of photovoltaic power, which is unique to the hybrid scheme considered in this work. Storage capacity calculations for different conditions using the proposed approach, satisfies the constraints of maintaining zero LPSP and also improved cycle life of the battery bank

  1. Automatic Generation of Connectivity for Large-Scale Neuronal Network Models through Structural Plasticity.

    Science.gov (United States)

    Diaz-Pier, Sandra; Naveau, Mikaël; Butz-Ostendorf, Markus; Morrison, Abigail

    2016-01-01

    With the emergence of new high performance computation technology in the last decade, the simulation of large scale neural networks which are able to reproduce the behavior and structure of the brain has finally become an achievable target of neuroscience. Due to the number of synaptic connections between neurons and the complexity of biological networks, most contemporary models have manually defined or static connectivity. However, it is expected that modeling the dynamic generation and deletion of the links among neurons, locally and between different regions of the brain, is crucial to unravel important mechanisms associated with learning, memory and healing. Moreover, for many neural circuits that could potentially be modeled, activity data is more readily and reliably available than connectivity data. Thus, a framework that enables networks to wire themselves on the basis of specified activity targets can be of great value in specifying network models where connectivity data is incomplete or has large error margins. To address these issues, in the present work we present an implementation of a model of structural plasticity in the neural network simulator NEST. In this model, synapses consist of two parts, a pre- and a post-synaptic element. Synapses are created and deleted during the execution of the simulation following local homeostatic rules until a mean level of electrical activity is reached in the network. We assess the scalability of the implementation in order to evaluate its potential usage in the self generation of connectivity of large scale networks. We show and discuss the results of simulations on simple two population networks and more complex models of the cortical microcircuit involving 8 populations and 4 layers using the new framework.

  2. NUMERICAL RESEARCH TECHNIQUES OF MAGNETIC FIELDS GENERATED BY INDUCTION CURRENTS IN A MASSIVE CONDUCTOR

    OpenAIRE

    Tchernykh A. G.

    2015-01-01

    We consider the technology of application of numerical methods in the educational process in physics on the example of a study of the magnetic field induced by induction currents in a cylindrical conductor in a quasi-stationary magnetic field. Here is given the numerical calculation of the real and imaginary parts of the Bessel functions of complex argument. The listing of the program of drawing the graphs of the radial dependence of the amplitude and phase shift of the inductive currents fie...

  3. Power Quality Improvement Utilizing Photovoltaic Generation Connected to a Weak Grid

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Tumbelaka, Hanny H. [Petra Christian University; Gao, Wenzhong [UNiversity of Denver

    2017-11-07

    Microgrid research and development in the past decades have been one of the most popular topics. Similarly, the photovoltaic generation has been surging among renewable generation in the past few years, thanks to the availability, affordability, technology maturity of the PV panels and the PV inverter in the general market. Unfortunately, quite often, the PV installations are connected to weak grids and may have been considered as the culprit of poor power quality affecting other loads in particular sensitive loads connected to the same point of common coupling (PCC). This paper is intended to demystify the renewable generation, and turns the negative perception into positive revelation of the superiority of PV generation to the power quality improvement in a microgrid system. The main objective of this work is to develop a control method for the PV inverter so that the power quality at the PCC will be improved under various disturbances. The method is to control the reactive current based on utilizing the grid current to counteract the negative impact of the disturbances. The proposed control method is verified in PSIM platform. Promising results have been obtained.

  4. Dynamic analysis of combined photovoltaic source and synchronous generator connected to power grid

    Science.gov (United States)

    Mahabal, Divya

    In the world of expanding economy and technology, the energy demand is likely to increase even with the global efforts of saving and increasing energy efficiency. Higher oil prices, effects of greenhouse gases, and concerns over other environmental impacts gave way to Distributed Generation (DG). With adequate awareness and support, DG's can meet these rising energy demands at lower prices compared to conventional methods. Extensive research is taking place in different areas like fuel cells, photovoltaic cells, wind turbines, and gas turbines. DG's when connected to a grid increase the overall efficiency of the power grid. It is believed that three-fifth of the world's electricity would account for renewable energy by middle of 21st century. This thesis presents the dynamic analysis of a grid connected photovoltaic (PV) system and synchronous generator. A grid is considered as an infinite bus. The photovol-taic system and synchronous generator act as small scale distributed energy resources. The output of the photovoltaic system depends on the light intensity, temperature, and irradiance levels of sun. The maximum power point tracking and DC/AC converter are also modeled for the photovoltaic system. The PV system is connected to the grid through DC/AC system. Different combinations of PV and synchronous generator are modeled with the grid to study the dynamics of the proposed system. The dynamics of the test system is analyzed by subjecting the system to several disturbances under various conditions. All modules are individually modeled and con-nected using MATLAB/Simulink software package. Results from the study show that, as the penetration of renewable energy sources like PV increases into the power system, the dynamics of the system becomes faster. When considering cases such as load switching, PV cannot deliver more power as the performance of PV depends on environmental conditions. Synchronous generator in power system can produce the required amount of

  5. Active and reactive power neurocontroller for grid-connected photovoltaic generation system

    Directory of Open Access Journals (Sweden)

    I. Abadlia

    2016-03-01

    Full Text Available Many researchers have contributed to the development of a firm foundation for analysis and design of control applications in grid-connected renewable energy sources. This paper presents an intelligent control algorithm fond on artificial neural networks for active and reactive power controller in grid-connected photovoltaic generation system. The system is devices into two parts in which each part contains an inverter with control algorithm. A DC/DC converter in output voltage established by control magnitude besides maximum power point tracker algorithm always finds optimal power of the PV array in use. A DC/AC hysteresis inverter designed can synchronize a sinusoidal current output with the grid voltage and accurate an independent active and reactive power control. Simulation results confirm the validation of the purpose. Neurocontroller based active and reactive power presents an efficiency control that guarantees good response to the steps changing in active and reactive power with an acceptable current/voltage synchronism. In this paper the power circuit and the control system of the presented grid-connected photovoltaic generation system is simulated and tested by MatLab/Simulink.

  6. Generation of a vascularized organoid using skeletal muscle as the inductive source.

    LENUS (Irish Health Repository)

    Messina, Aurora

    2005-09-01

    The technology required for creating an in vivo microenvironment and a neovasculature that can grow with and service new tissue is lacking, precluding the possibility of engineering complex three-dimensional organs. We have shown that when an arterio-venous (AV) loop is constructed in vivo in the rat groin, and placed inside a semisealed chamber, an extensive functional vasculature is generated. To test whether this unusually angiogenic environment supports the survival and growth of implanted tissue or cells, we inserted various preparations of rat and human skeletal muscle. We show that after 6 weeks incubation of muscle tissue, the chamber filled with predominantly well-vascularized recipient-derived adipose tissue, but some new donor-derived skeletal muscle and connective tissue were also evident. When primary cultured myoblasts were inserted into the chamber with the AV loop, they converted to mature striated muscle fibers. Furthermore, we identify novel adipogenesis-inducing properties of skeletal muscle. This represents the first report of a specific three-dimensional tissue grown on its own vascular supply.

  7. Reliability Oriented Design Tool For the New Generation of Grid Connected PV-Inverters

    DEFF Research Database (Denmark)

    Sintamarean, Nicolae Cristian; Blaabjerg, Frede; Wang, Huai

    2015-01-01

    is achieved and is further used as an input to the lifetime model. The proposed reliability-oriented design tool is used to study the impact of mission profile (MP) variation and device degradation (aging) in the PV inverter lifetime. The obtained results indicate that the MP of the field where the PV...... inverter is operating has an important impact (up to 70%) on the converter lifetime expectation, and it should be considered in the design stage to better optimize the converter design margin. In order to have correct lifetime estimation, it is crucial to consider also the device degradation feedback (in......This paper introduces a reliability-oriented design tool for a new generation of grid-connected photovoltaic (PV) inverters. The proposed design tool consists of a real field mission profile (RFMP) model (for two operating regions: USA and Denmark), a PV panel model, a grid-connected PV inverter...

  8. Modified Grid-Connected CSI for Hybrid PV/Wind Power Generation System

    Directory of Open Access Journals (Sweden)

    D. Amorndechaphon

    2012-01-01

    Full Text Available The principle of a power conditioning unit for hybrid PV/wind power generation system is proposed. The proposed power conditioner is based on the current source inverter (CSI topology. All energy sources are connected in parallel with a DC-bus through the modified wave-shaping circuits. To achieve the unity power factor at the utility grid, the DC-link current can be controlled via the wave-shaping circuits with the sinusoidal PWM scheme. In this work, the carrier-based PWM scheme is also proposed to minimize the utility current THD. The power rating of the proposed system can be increased by connecting more PV/wind modules through their wave-shaping circuits in parallel with the other modules. The details of the operating principles, the system configurations, and the design considerations are described. The effectiveness of the proposed CSI is demonstrated by simulation results.

  9. Analysis and MPPT control of a wind-driven three-phase induction generator feeding single-phase utility grid

    Directory of Open Access Journals (Sweden)

    Krishnan Arthishri

    2017-05-01

    Full Text Available In this study, a three-phase diode bridge rectifier and a single-phase voltage source inverter topology has been proposed for feeding single-phase utility grid employing a three-phase induction generator fed from wind energy. A self-excited induction generator configuration has been chosen for wide speed operation of wind turbine system, which gives the scope for extracting maximum power available in the wind. In addition to maximum power point tracking (MPPT, the generator can be loaded to its rated capacity for feeding single-phase utility grid using a three-phase induction machine, whereas it is not possible with existing configurations because of the absence of power converters. For the proposed system, MPPT algorithm has been devised by continuously monitoring the grid current and a proportional resonant controller has been employed for grid synchronisation of voltage source inverter with single-phase grid. A MATLAB/Simulink model of the proposed system has been developed to ascertain its successful working by predetermining the overall performance characteristics. The present proposal has also been tested with sag, swell and distortion in the grid voltage. The control strategy has been implemented using field programmable gate array (FPGA controller with modularised programming approach. The efficacy of the system has been demonstrated with the results obtained from an experimental set-up in the laboratory.

  10. Artificial Bee Colony Algorithm for Transient Performance Augmentation of Grid Connected Distributed Generation

    Science.gov (United States)

    Chatterjee, A.; Ghoshal, S. P.; Mukherjee, V.

    In this paper, a conventional thermal power system equipped with automatic voltage regulator, IEEE type dual input power system stabilizer (PSS) PSS3B and integral controlled automatic generation control loop is considered. A distributed generation (DG) system consisting of aqua electrolyzer, photovoltaic cells, diesel engine generator, and some other energy storage devices like flywheel energy storage system and battery energy storage system is modeled. This hybrid distributed system is connected to the grid. While integrating this DG with the onventional thermal power system, improved transient performance is noticed. Further improvement in the transient performance of this grid connected DG is observed with the usage of superconducting magnetic energy storage device. The different tunable parameters of the proposed hybrid power system model are optimized by artificial bee colony (ABC) algorithm. The optimal solutions offered by the ABC algorithm are compared with those offered by genetic algorithm (GA). It is also revealed that the optimizing performance of the ABC is better than the GA for this specific application.

  11. Control and Modulation Techniques for a Centralized PV Generation System Grid Connected via an Interleaved Inverter

    Directory of Open Access Journals (Sweden)

    Gianluca Brando

    2016-09-01

    Full Text Available In the context of grid connected photovoitaic (PV generation systems, there are two paramount aspects regarding the Maximum Power Point Tracking (MPPT of the photovoltaic units and the continuity of the service. The most diffused MPPT algorithms are based on either perturb and observe, or on an incremental conductance approach and need both PV current and voltage measurements. Several topology reconfigurable converters are also associated with the PV plants, guaranteeing fault-tolerant features. The generation continuity can also be assured by interleaved inverters, which keep the system operating at reduced maximum power in case of failure. In this paper, an evolution of a hysteresis based MPPT algorithm is presented, based on the measurement of only one voltage, together with a novel space vector modulation suitable for a two-channel three-phase grid connected interleaved inverter. The proposed MMPT algorithm and modulation technique are tested by means of several numerical analyses on a PV generation system of about 200 kW maximum power. The results testify the validity of the proposed strategies, showing good performance, even during a fault occurrence and in the presence of deep shading conditions.

  12. A New Current Control Strategy of Maximizing The Generated Power From a Doubly Fed Induction Generator System

    DEFF Research Database (Denmark)

    Li, Hui; Chen, Zhe

    2006-01-01

    Switched reluctance generator (SR Generator) has various desirable features which include simple and solid structure, easiness of maintenance, small moment of rotor inertia and low cost. However, the SR generator has not been put into practical use widely because an optimum design of SR generator...... is consist of half number of switching devices for the AHBC. The operating characteristics of the SR generators were discussed based on FEM analysis and experiments....

  13. Generation-Side Power Scheduling in a Grid-Connected DC Microgrid

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Meng, Lexuan

    2015-01-01

    In this paper, a constrained mixed-integer programming model for scheduling the active power supplied by the generation units in storage-based DC microgrids is presented. The optimization problem minimizes operating costs taking into account a two-stage mode operation of the energy storage system...... so that a more accurate model for optimization of the microgrid operation can be obtained. The model is used in a particular grid-connected DC microgrid that includes two renewable energy sources and an energy storage system which supply a critical load. The results of the scheduling process...

  14. Models for the transient stability of conventional power generating stations connected to low inertia systems

    Science.gov (United States)

    Zarifakis, Marios; Coffey, William T.; Kalmykov, Yuri P.; Titov, Sergei V.

    2017-06-01

    An ever-increasing requirement to integrate greater amounts of electrical energy from renewable sources especially from wind turbines and solar photo-voltaic installations exists and recent experience in the island of Ireland demonstrates that this requirement influences the behaviour of conventional generating stations. One observation is the change in the electrical power output of synchronous generators following a transient disturbance especially their oscillatory behaviour accompanied by similar oscillatory behaviour of the grid frequency, both becoming more pronounced with reducing grid inertia. This behaviour cannot be reproduced with existing mathematical models indicating that an understanding of the behaviour of synchronous generators, subjected to various disturbances especially in a system with low inertia requires a new modelling technique. Thus two models of a generating station based on a double pendulum described by a system of coupled nonlinear differential equations and suitable for analysis of its stability corresponding to infinite or finite grid inertia are presented. Formal analytic solutions of the equations of motion are given and compared with numerical solutions. In particular the new finite grid model will allow one to identify limitations to the operational range of the synchronous generators used in conventional power generation and also to identify limits, such as the allowable Rate of Change of Frequency which is currently set to ± 0.5 Hz/s and is a major factor in describing the volatility of a grid as well as identifying requirements to the total inertia necessary, which is currently provided by conventional power generators only, thus allowing one to maximise the usage of grid connected non-synchronous generators, e.g., wind turbines and solar photo-voltaic installations.

  15. Integration of a finite element generator model into a simulated HVDC connected system

    Energy Technology Data Exchange (ETDEWEB)

    Preston, T W; Sturgess, J P [GEC Alsthom Engineering Research Center, Stafford (United Kingdom)

    1994-12-31

    Within most system analysis programs generators and motors are represented by an equivalent circuit model either a 2-axis model for both stators and rotor or a three-phase model of the stator and a two-axis model of the rotor. This may be adequate under certain operating conditions such as steady-state or some symmetrical faults but for inverter-fed motors or generators feeding into a rectified load a more rigorous model of the machine is required. This paper describes the theory and development of such a model, its integration with the power electronics and application to 6-pulse and 12-pulse converters, the latter being appropriate in systems similar to HVDC unit connection. (author) 5 refs., 16 figs.

  16. Evaluation of tube to collector connection by hydraulic expansion method in PGV-1000 steam generators

    International Nuclear Information System (INIS)

    Dashti, H.G.; Hashemi, B.; Jahromi, S.A.

    2011-01-01

    Research highlights: → The produced residual stresses in the collector body due to hydraulic expansion method have been compared with explosive method. → The residual stresses were obtained using two methods of FEM and strain gauging tests. → The effect of clearance between tube and collector on the residual stresses was investigated. → The contact stresses between the tube and collector interface were modeled and the required connection strength between tube and collector is estimated based on ASME rules and compared with FE results. - Abstract: Investigations on steam generators failure due to cracking in collector ligaments at perforated parts determined that connection process of the tubes to collector could be one of the main breakdown causes. The stability and strength of tube to collector joint is dependent to the geometry of tube and collector, the joining process and the operational conditions. In this research hydraulic expansion method has been considered as connection method of tube to collector. The Finite Element Method (FEM) was used to simulate the hydraulic expansion process and determine stress condition of the joints. The contact stresses between the tube and collector interface were modeled using contact elements of ANSYS program. Furthermore, the effect of clearance between tube and collector on the residual stresses around of joints was investigated. Some specimens from collector and tube materials were tested at various temperatures and their results were used at rate-independent multi-linear Mises plasticity model for FE analysis. Required connection strength between tube and collector is estimated based on ASME rules and compared with FE results. The results show that the residual tensile stresses could be greatly increased by decreasing of initial clearance. The highest value of residual stresses was observed around of collector holes nevertheless it was considerably lesser than obtained residual stresses in explosive method. The

  17. Self-Excited Induction Generator Based Microgrid with Supercapacitor Energy Storage to Support the Start-up of Dynamic Loads

    Directory of Open Access Journals (Sweden)

    ION, C. P.

    2018-05-01

    Full Text Available A supercapacitor storage system (SCSS is used for improving the dynamic performances of a microgrid (MG fed by a self-excited induction generator (SEIG, in the case of the direct start-up of an induction motor (IM of comparable power. The primary control system contains a voltage source inverter (VSI with a dump load (DL, to which the SCSS is added. The control strategy for the SCSS consists of injecting power into the VSI DC-link when, because of the overload created by the IM, the DC voltage decreases under the acceptable limit. Thus, the overall performance of the SEIG-supplied MG is significantly improved. Simulations and experimental results accomplished on a laboratory-scale MG validate the effectiveness of the proposed control structure.

  18. Reduced-Capacity Inrush Current Suppressor Using a Matrix Converter in a Wind Power Generation System with Squirrel-Cage Induction Machines

    Directory of Open Access Journals (Sweden)

    Sho Shibata

    2016-03-01

    Full Text Available This paper describes the reduced capacity of the inrush current suppressor using a matrix converter (MC in a large-capacity wind power generation system (WPGS with two squirrel-cage induction machines (SCIMs. These SCIMs are switched over depending on the wind speed. The input side of the MC is connected to the source in parallel. The output side of the MC is connected in series with the SCIM through matching transformers. The modulation method of the MC used is direct duty ratio pulse width modulation. The reference output voltage of the MC is decided by multiplying the SCIM current with the variable control gain. Therefore, the MC performs as resistors for the inrush current. Digital computer simulation is implemented to confirm the validity and practicability of the proposed inrush current suppressor using PSCAD/EMTDC (power system computer-aided design/electromagnetic transients including DC. Furthermore, the equivalent resistance of the MC is decided by the relationship between the equivalent resistance and the capacity of the MC. Simulation results demonstrate that the proposed inrush current suppressor can suppress the inrush current perfectly.

  19. Functional Dependence for Calculation of Additional Real-Power Losses in a Double-Wound Supply Transformer Caused by Unbalanced Active Inductive Load in a Star Connection with an Insulated Neutral

    Science.gov (United States)

    Kostinskiy, Sergey S.; Troitskiy, Anatoly I.

    2016-01-01

    This article deals with the problem of calculating the additional real-power losses in double-wound supply transformers with voltage class 6 (10)/0,4 kV, caused by unbalanced active inductive load connected in a star connection with an insulated neutral. When solving the problem, authors used the theory of electric circuits, method of balanced…

  20. Practicing induction:

    DEFF Research Database (Denmark)

    Sprogøe, Jonas; Rohde, Nicolas

    2009-01-01

    We claim that induction potentially triggers both individual and organizational learning and by drawing on practice-based theory we discuss how the interplay between individual and organization, what we call a generative dance, ignites both kinds of learning.......We claim that induction potentially triggers both individual and organizational learning and by drawing on practice-based theory we discuss how the interplay between individual and organization, what we call a generative dance, ignites both kinds of learning....

  1. Análisis y modelado del generador de inducción doblemente alimentado. Analysis and Modeling of Doubly Fed Induction Generators.

    Directory of Open Access Journals (Sweden)

    Lesyani T. León Viltre

    2015-04-01

    Full Text Available Uno de los generadores eólicos de velocidad variable más utilizados en la actualidad es el generador de inducción doblemente alimentado (DFIG. En el presente trabajo se presenta un esquema de control del DFIG. El convertidor de potencia del lado de la red es modelado y controlado usando el vector de tensión orientado a los ejes dq, lo que garantiza que con la componente del eje d de la corriente se pueda controlar la potencia activa y, por consiguiente, la tensión del bus DC. La componente del eje q es forzada a cero para mantener un factor de potencia unitario. En el convertidor del lado del rotor se utiliza un control orientado al flujo del estator. Para la sincronización con la red se utiliza un método novedoso basado en el método GDSC-PLL (Generalizad delayed signal cancellation. Además, se presenta un análisis del comportamiento del DFIG, ante huecos de tensión.  One of the variable speed wind turbines most commonly used today is the doubly feed induction generator(DFIG.A control scheme of DFIG is discussed in this paper. The power converter connected to the grid side (bus is modeled and controlled using voltage vectororiented dq reference frame, whichguarantees that the active power can be controlled by the daxiscurrent component and consequently the DC bus voltage. The qaxis component is forced to be zero in order to ensurethe unitary power factor. Astator flux oriented control in the rotor circuit converter is used.A novel GDSC-PLL method is used in order to achieve an efficient synchronization with the grid.Onthe order hand, this paper presents an analysis about the DFIG (Double Feed Induction Generator behavior during voltages sags.

  2. Análisis y modelado del generador de inducción doblemente alimentado; Analysis and Modeling of Doubly Fed Induction Generators

    Directory of Open Access Journals (Sweden)

    Lesyani T- León Viltre

    2014-06-01

    Full Text Available Uno de los generadores eólicos de velocidad variable más utilizados en la actualidad es el generador de inducción doblemente alimentado (DFIG. En el presente trabajo se presenta un esquema de control del DFIG. El convertidor de potencia del lado de la red es modelado y controlado usando el vector de tensión orientado a los ejes dq, lo que garantiza que con la componente del eje d de la corriente se pueda controlar la potencia activa y, por consiguiente, la tensión del bus DC. La componente del eje q es forzada a cero para mantener un factor de potencia unitario. En el convertidor del lado del rotor se utiliza un control orientado al flujo del estator. Para la sincronización con la red se utiliza un método novedoso basado en el método GDSC-PLL (Generalizad delayed signal cancellation. Además, se presenta un análisis del comportamiento del DFIG, ante huecos de tensión. One of the variable speed wind turbines most commonly used today is the doubly feed induction generator(DFIG.A control scheme of DFIG is discussed in this paper. The power converter connected to the grid side (bus is modeled and controlled using voltage vectororiented dq reference frame, whichguarantees that the active power can be controlled by the daxiscurrent component and consequently the DC bus voltage. The qaxis component is forced to be zero in order to ensurethe unitary power factor. Astator flux oriented control in the rotor circuit converter is used.A novel GDSC-PLL method is used in order to achieve an efficient synchronization with the grid.Onthe order hand, this paper presents an analysis about the DFIG (Double Feed Induction Generator behavior during voltages sags

  3. Application of Boost Converter to Increase the Speed Range of Dual-stator Winding Induction Generator in Wind Power Systems

    DEFF Research Database (Denmark)

    Kavousi, Ayoub; Fathi, S. Hamid; Milimonfared, Jafar

    2018-01-01

    In this paper, a topology using a Dual-stator Winding Induction Generator (DWIG) and a boost converter is proposed for the variable speed wind power application. At low rotor speeds, the generator saturation limits the voltage of the DWIG. Using a boost converter, higher DC voltage can be produced...... while the DWIG operates at Maximum Power Point Tracking (MPPT) even at low speed and low voltage conditions. Semiconductor Excitation Controller (SEC) of the DWIG utilizes Control-Winding Voltage Oriented Control (CWVOC) method to adjust the voltage, considering V/f characteristics. For the proposed...... topology, the SEC capacity and the excitation capacitor is optimized by analyzing the SEC reactive current considering wind turbine power-speed curve, V/f strategy, and the generator parameters. The method shows that the per-unit capacity of the SEC can be limited to the inverse of DWIG magnetizing...

  4. Reduced Cost of Reactive Power in Doubly Fed Induction Generator Wind Turbine System with Optimized Grid Filter

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede; Franke, Toke

    2014-01-01

    The modern grid requirement has caused that the wind power system behaves more like conventional rotating generators and it is able to support certain amount of the reactive power. For a typical doubly-fed induction generator wind turbine system, the reactive power can be supported either through...... for the generator and the wind power converter in terms of the reactive power done by the rotor-side converter or the grid-side converter with various grid filters. Afterwards, the annual energy loss is also estimated based on yearly wind profile. Finally, experimental results of the loss distribution are performed...... the rotor-side converter or the grid-side converter. This paper firstly compares the current ripples and supportive reactive power ranges between the conventional L and optimized LCL filter, if the reactive power is injected from the grid-side converter. Then, the loss distribution is evaluated both...

  5. Reduced Cost of Reactive Power in Doubly Fed Induction Generator Wind Turbine System With Optimized Grid Filter

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede; Franke, Toke

    2015-01-01

    The modern grid requirement has caused that the wind power system behaves more like conventional rotating generators, and it is able to support certain amount of the reactive power. For a typical doubly fed induction generator (DFIG) wind turbine system, the reactive power can be supported either...... for the generator and the wind power converter in terms of the reactive power done by the rotor-side converter or the grid-side converter with various grid filters. Afterward, the annual energy loss is also estimated based on yearly wind profile. Finally, experimental results of the loss distribution are performed...... through the rotor-side converter or the grid-side converter. This paper first compares the current ripples and supportive reactive power ranges between the conventional L and optimized LCL filter, if the reactive power is injected from the grid-side converter. Then, the loss distribution is evaluated both...

  6. An improved excitation control technique of three-phase induction machine operating as dual winding generator for micro-wind domestic application

    International Nuclear Information System (INIS)

    Chatterjee, Arunava; Chatterjee, Debashis

    2015-01-01

    Highlights: • A three-phase induction machine working as single phase generator is studied. • The generator is assisted by an inverter and photovoltaic panel for excitation. • Proposed control involves operating the machine as balanced two-phase generator. • Torque pulsations associated with unbalanced phase currents are minimized. • The generator can be used for grid-isolated micro-wind power generation. - Abstract: Single-phase generation schemes are widely utilized for harnessing wind power in remote and grid secluded applications. This paper presents a novel control methodology for a three-phase induction machine working as a single-phase dual winding induction generator. Three-phase induction machines providing single-phase output with proper control strategy can be beneficial in grid secluded micro-wind energy conversion systems compared to single-phase induction generators. Three-phase induction machines operating in single-phase mode are mostly excited asymmetrically to provide single-phase power leading to unbalanced current flow in the stator windings causing heating and insulation breakdown. The asymmetrical excitation also initiates torque pulsations which results in additional stress and vibration at the machine shaft and bearings degrading the machine performance. The proposed control is chiefly aimed to minimize this unbalance. The variable excitation required for the proposed generator is provided through a single-phase inverter with photovoltaic panels. The suitability for such a generator along with its control is tested with appropriate simulations and experimental results. The induction generator with the proposed control strategy is expected to be useful in remote and grid isolated households as a standalone source of single-phase electrical power

  7. Development of a direct hydride generation nebulizer for the determination of selenium by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Carrion, Nereida; Murillo, Miguel; Montiel, Edie; Diaz, Dorfe

    2003-01-01

    A study was conducted to evaluate the performance of a new direct hydride generation nebulizer system for determination of hydride forming elements by inductively coupled plasma optical emission spectroscopy. This system was designed and optimized to obtain the highest sensitivity. Several experimental designs were used for these purposes. To optimize the individual parameters of the system, and to study the interaction between these parameters for both direct hydride generation nebulizers, a central composite orthogonal design with eight factors was set up. Significant behavioral differences were observed in the two direct hydride generation nebulizers studied. Finally, a 70 μm gas orifice nebulizer exhibits a better detection limit than the 120 μm nebulizer. Generally, for determination of selenium, this new direct hydride generation nebulizer system exhibits a linear dynamic range and detection limit (3σb) of 3 orders of magnitude and 0.2 μg l -1 for selenium, respectively. This new hydride generator is much simpler system that conventional hydride generation systems, which does not need to be changed to work in normal mode with the inductively coupled plasma, since this system may be used for hydride forming elements and those that do not form them. It produces a rapid response with low memory effect. It reduces the interference level of Ni, Co and Cu to 600, 500 and 5 mg l -1 , respectively. The accuracy of the system was verified by the determination of selenium in several standard reference materials of ambient, food and clinical sample matrices. No statistically significant differences (95 confidence level) were obtained between our method and the reference values

  8. Operational characteristic analysis of PV generation system for grid connection by using a senseless MPPT control

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.-J.; Kim, K.-H.; Park, H.-Y.; Seo, H.-R.; Park, M.; Yu, I.-K. [Changwon National Univ., SarimDong (Korea, Republic of). Dept. of Electrical Engineering

    2007-07-01

    In photovoltaics, the sun's light energy is captured to create electricity. One of the key issues about a photovoltaic (PV) generation system is to keep the output power of photovoltaic cells maximized under any weather conditions. In a conventional maximum power point tracking (MPPT) control method, both voltage and current coming out from PV array require feedback. The system may fail to track the MPP of a PV array when unexpected weather conditions happen. This paper proposed a novel PV output senseless (POS) control method to solve the problem. The proposed POS MPPT control method only had one factor to consider, the load current. To verify this theory, a POS MPPT control was applied to a manufactured PV generation system, and the results of the the simulated and experimental data under real weather conditions were compared and analyzed. Several tables and diagrams were presented, including the circuit diagram of a manufactured PV generation system connected to grid as well as the the specifications of the PV array and PCS used for the experiment. Reasonable results were obtained in this study. In addition, the scheme was found to be very useful in maximizing power from PV array to load with feedback of only the load current. 8 refs., 3 tabs., 15 figs.

  9. Fault-tolerant control for current sensors of doubly fed induction generators based on an improved fault detection method

    DEFF Research Database (Denmark)

    Li, Hui; Yang, Chao; Hu, Yaogang

    2014-01-01

    Fault-tolerant control of current sensors is studied in this paper to improve the reliability of a doubly fed induction generator (DFIG). A fault-tolerant control system of current sensors is presented for the DFIG, which consists of a new current observer and an improved current sensor fault...... detection algorithm, and fault-tolerant control system are investigated by simulation. The results indicate that the outputs of the observer and the sensor are highly coherent. The fault detection algorithm can efficiently detect both soft and hard faults in current sensors, and the fault-tolerant control...

  10. Optimal Controller Design of a Wind Turbine with Doubly Fed Induction Generator for Small Signal Stability Enhancement

    DEFF Research Database (Denmark)

    Yang, Lihui; Yang, Guangya; Xu, Zhao

    2010-01-01

    Multi-objective optimal controller design of a doubly fed induction generator (DFIG) wind turbine system using Differential Evolution (DE) is presented in this chapter. A detailed mathematical model of DFIG wind turbine with a close loop vector control system is developed. Based on this, objective...... functions, addressing the steady state stability and dynamic performance at different operating conditions are implemented to optimize the controller parameters of both the rotor and grid side converters. A superior ε-constraint method and method of adaptive penalties are applied to handle the multi...

  11. A multi-objective control strategy for grid connection of DG (distributed generation) resources

    Energy Technology Data Exchange (ETDEWEB)

    Pouresmaeil, Edris; Montesinos-Miracle, Daniel; Bergas-Jane, Joan [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Departament d' Enginyeria Electrica, Universitat Politecnica de Catalunya, ETS d' Enginyeria Industrial de Barcelona (Spain); Gomis-Bellmunt, Oriol [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Departament d' Enginyeria Electrica, Universitat Politecnica de Catalunya, ETS d' Enginyeria Industrial de Barcelona (Spain); Catalonia Institute for Energy Research IREC, Barcelona (Spain)

    2010-12-15

    This paper presents a flexible control technique for connection of DG (distributed generation) resources to distribution networks, especially during ride-through on faulty grid. This strategy is derived from the abc/{alpha}{beta} and {alpha}{beta}/dq transformations of the ac system variables. The active and reactive currents injected by the DG source are controlled in the synchronously rotating orthogonal dq reference frame. The transformed variables are used to control the VSI (voltage source inverter) which connects the DG to the distribution network. Using a P.L.L. (phase locked loop) in circuit of proposed control technique, the angle of positive sequence has been detected, in order to synchronize the currents to the distribution network. The proposed control technique has the capability of providing active and reactive powers and harmonic currents to nonlinear loads with a fast dynamic response. Simulation results and mathematical analysis have been completed in order to achieve a reduced THD (total harmonic distortion), increased power factor and compensated load's active and reactive powers. The analyses show the high performance of this control strategy in DG applications in comparison with other existing strategies. (author)

  12. A report on the performance of a grid connected photovoltaic power generation system

    International Nuclear Information System (INIS)

    Mohd Azhar Abdul Rahman; Mohd Surif Abdul Wahab; Azmi Omar

    2000-01-01

    Malaysia is located almost on the equator and is blessed with an abundance of sunlight almost all year round. So obviously, with the right planning and strategies that are coupled to the right technology and development in the market, the potential for photovoltaic system as an alternative source of power in this country looks promising and is constantly gaining ground and popularity. Sunlight is free and the photovoltaic system is also emission and pollution free which is a guest boost to the current worldwide effort to reduce the global environmental problems. Utility giant Tenaga Nasional Berhad is in line with the Government aspiration to promote the development of solar photovoltaic in the country, who believe in the success and acceptance potential of the photovoltaic system as an alternative source of power generation for long term energy option. In March 1998, a contract was awarded by Tenaga Nasional Berhad to its research subsidiary, Tenaga Nasional Research and Development Sdn. Bhd. to undertake a pilot research project on the development of a grid connected photovoltaic system. This research project is co-funded by the Electric Supply Industry Trust fund. One of the main objective of this research project is to seek the best approach to popularize the Grid Connected Photovoltaic System for domestic as well as suitable commercial premises in this country. This paper will report the initial findings of the project in terms of technical capability and commercial liability. (Author)

  13. Generation of connectivity-preserving surface models of multiple sclerosis lesions.

    Science.gov (United States)

    Meruvia-Pastor, Oscar; Xiao, Mei; Soh, Jung; Sensen, Christoph W

    2011-01-01

    Progression of multiple sclerosis (MS) results in brain lesions caused by white matter inflammation. MS lesions have various shapes, sizes and locations, affecting cognitive abilities of patients to different extents. To facilitate the visualization of the brain lesion distribution, we have developed a software tool to build 3D surface models of MS lesions. This tool allows users to create 3D models of lesions quickly and to visualize the lesions and brain tissues using various visual attributes and configurations. The software package is based on breadth-first search based 3D connected component analysis and a 3D flood-fill based region growing algorithm to generate 3D models from binary or non-binary segmented medical image stacks.

  14. Facilitating efficient augmentation of transmission networks to connect renewable energy generation: the Australian experience

    International Nuclear Information System (INIS)

    Wright, Glen

    2012-01-01

    Australia is heavily dependent on coal for electricity generation. The Renewable Energy Target has spurred growth in the utilization of renewable energy sources, with further growth expected into the future. Australia's strongest renewable energy sources are generally distant from the transmission network in resource ‘basins’. Investment is needed to augment the transmission network to enable delivery of electricity from these sources to consumers. Considerable economies of scale flow from anticipating the connection of numerous generators in an area over time and sizing augmentations accordingly. Following a lengthy rulemaking process, the National Electricity Rules were recently amended by a new rule, designed to facilitate the construction of such efficiently sized augmentations. However, the new rule is more conservative than initially envisaged, making little substantive change to the current frameworks for augmentation and connection. This paper outlines these frameworks and the rulemaking process and identifies the key debates surrounding the rule change are identified. This paper then provides a detailed analysis of the new rule, concluding that it is defective in a number of respects and is unlikely to result in the efficient and timely augmentation of the network needed to unlock the potential of Australia's strongest renewable energy resources. - Highlights: ► Remoteness of renewable energy sources is a barrier to greater renewable energy utilization. ► Significant economies of scale flow from efficiently-sized transmission network augmentation. ► Current frameworks in Australia do not incentivise efficiently-sized network augmentations. ► The lack of property rights in an augmentation is particularly problematic. ► The new Scale Efficient Network Extensions rule is not apt to facilitate efficiently-sized network augmentations.

  15. NIMROD simulations and physics assessment of possible designs for a next generation Steady Inductive Helicity Injection HIT device

    Science.gov (United States)

    Penna, James; Morgan, Kyle; Grubb, Isaac; Jarboe, Thomas

    2017-10-01

    The Helicity Injected Torus - Steady Inductive 3 (HIT-SI3) experiment forms and maintains spheromaks via Steady Inductive Helicity Injection (SIHI) using discrete injectors that inject magnetic helicity via a non-axisymmetric perturbation and drive toroidally symmetric current. Newer designs for larger SIHI-driven spheromaks incorporate a set of injectors connected to a single external manifold to allow more freedom for the toroidal structure of the applied perturbation. Simulations have been carried out using the NIMROD code to assess the effectiveness of various imposed mode structures and injector schema in driving current via Imposed Dynamo Current Drive (IDCD). The results are presented here for varying flux conserver shapes on a device approximately 1.5 times larger than the current HIT-SI3 experiment. The imposed mode structures and spectra of simulated spheromaks are analyzed in order to examine magnetic structure and stability and determine an optimal regime for IDCD sustainment in a large device. The development of scaling laws for manifold operation is also presented, and simulation results are analyzed and assessed as part of the development path for the large scale device.

  16. Voltage Quality of Grid Connected Wind Turbines

    DEFF Research Database (Denmark)

    Chen, Zhe; Blaabjerg, Frede; Sun, Tao

    2004-01-01

    Grid connected wind turbines may cause quality problems, such as voltage variation and flicker. This paper discusses the voltage variation and flicker emission of grid connected wind turbines with doubly-fed induction generators. A method to compensate flicker by using a voltage source converter...

  17. Real-Time Control of Active and Reactive Power for Doubly Fed Induction Generator (DFIG-Based Wind Energy Conversion System

    Directory of Open Access Journals (Sweden)

    Aman Abdulla Tanvir

    2015-09-01

    Full Text Available This paper presents the modeling, rapid control prototyping, and hardware-in-the-loop testing for real-time simulation and control of a grid-connected doubly fed induction generator (DFIG in a laboratory-size wind turbine emulator for wind energy conversation systems. The generator is modeled using the direct-quadrature rotating reference frame circuit along with the aligned stator flux, and the field-oriented control approach is applied for independent control of the active and reactive power and the DC-link voltage at the grid side. The control of the active, reactive power and the DC-link voltage are performed using a back-to-back converter at sub- and super-synchronous as well as at variable speeds. The control strategy is experimentally validated on an emulated wind turbine driven by the Opal-RT real-time simulator (OP5600 for simultaneous control of the DC-link voltage, active and reactive power.

  18. Pre- and post-natal exposure of children to EMF generated by domestic induction cookers

    Science.gov (United States)

    Kos, Bor; Valič, Blaž; Miklavčič, Damijan; Kotnik, Tadej; Gajšek, Peter

    2011-10-01

    Induction cookers are a type of cooking appliance that uses an intermediate-frequency magnetic field to heat the cooking vessel. The magnetic flux density produced by an induction cooker during operation was measured according to the EN 62233 standard, and the measured values were below the limits set in the standard. The measurements were used to validate a numerical model consisting of three vertically displaced coaxial current loops at 35 kHz. The numerical model was then used to compute the electric field (E) and induced current (J) in 26 and 30 weeks pregnant women and 6 and 11 year old children. Both E and J were found to be below the basic restrictions of the 2010 low-frequency and 1998 ICNRIP guidelines. The maximum computed E fields in the whole body were 0.11 and 0.66 V m-1 in the 26 and 30 weeks pregnant women and 0.28 and 2.28 V m-1 in the 6 and 11 year old children (ICNIRP basic restriction 4.25 V m-1). The maximum computed J fields in the whole body were 46 and 42 mA m-2 in the 26 and 30 weeks pregnant women and 27 and 16 mA m-2 in the 6 and 11 year old children (ICNIRP basic restriction 70 mA m-2).

  19. Pre- and post-natal exposure of children to EMF generated by domestic induction cookers

    International Nuclear Information System (INIS)

    Kos, Bor; Miklavcic, Damijan; Kotnik, Tadej; Valic, Blaz; Gajsek, Peter

    2011-01-01

    Induction cookers are a type of cooking appliance that uses an intermediate-frequency magnetic field to heat the cooking vessel. The magnetic flux density produced by an induction cooker during operation was measured according to the EN 62233 standard, and the measured values were below the limits set in the standard. The measurements were used to validate a numerical model consisting of three vertically displaced coaxial current loops at 35 kHz. The numerical model was then used to compute the electric field (E) and induced current (J) in 26 and 30 weeks pregnant women and 6 and 11 year old children. Both E and J were found to be below the basic restrictions of the 2010 low-frequency and 1998 ICNRIP guidelines. The maximum computed E fields in the whole body were 0.11 and 0.66 V m -1 in the 26 and 30 weeks pregnant women and 0.28 and 2.28 V m -1 in the 6 and 11 year old children (ICNIRP basic restriction 4.25 V m -1 ). The maximum computed J fields in the whole body were 46 and 42 mA m -2 in the 26 and 30 weeks pregnant women and 27 and 16 mA m -2 in the 6 and 11 year old children (ICNIRP basic restriction 70 mA m -2 ).

  20. Pre- and post-natal exposure of children to EMF generated by domestic induction cookers

    Energy Technology Data Exchange (ETDEWEB)

    Kos, Bor; Miklavcic, Damijan; Kotnik, Tadej [Laboratory of Biocybernetics, Faculty of Electrical Engineering, University of Ljubljana, Trzaska 25, SI-1000 Ljubljana (Slovenia); Valic, Blaz; Gajsek, Peter, E-mail: bor.kos@fe.uni-lj.si, E-mail: damijan.miklavcic@fe.uni-lj.si, E-mail: tadej.kotnik@fe.uni-lj.si, E-mail: blaz.valic@inis.si, E-mail: p.gajsek@inis.si [Institute of Non-Ionizing Radiation, Pohorskega Bataljona 215, SI-1000 Ljubljana (Slovenia)

    2011-10-07

    Induction cookers are a type of cooking appliance that uses an intermediate-frequency magnetic field to heat the cooking vessel. The magnetic flux density produced by an induction cooker during operation was measured according to the EN 62233 standard, and the measured values were below the limits set in the standard. The measurements were used to validate a numerical model consisting of three vertically displaced coaxial current loops at 35 kHz. The numerical model was then used to compute the electric field (E) and induced current (J) in 26 and 30 weeks pregnant women and 6 and 11 year old children. Both E and J were found to be below the basic restrictions of the 2010 low-frequency and 1998 ICNRIP guidelines. The maximum computed E fields in the whole body were 0.11 and 0.66 V m{sup -1} in the 26 and 30 weeks pregnant women and 0.28 and 2.28 V m{sup -1} in the 6 and 11 year old children (ICNIRP basic restriction 4.25 V m{sup -1}). The maximum computed J fields in the whole body were 46 and 42 mA m{sup -2} in the 26 and 30 weeks pregnant women and 27 and 16 mA m{sup -2} in the 6 and 11 year old children (ICNIRP basic restriction 70 mA m{sup -2}).

  1. Self-Powered Random Number Generator Based on Coupled Triboelectric and Electrostatic Induction Effects at the Liquid-Dielectric Interface.

    Science.gov (United States)

    Yu, Aifang; Chen, Xiangyu; Cui, Haotian; Chen, Libo; Luo, Jianjun; Tang, Wei; Peng, Mingzeng; Zhang, Yang; Zhai, Junyi; Wang, Zhong Lin

    2016-12-27

    Modern cryptography increasingly employs random numbers generated from physical sources in lieu of conventional software-based pseudorandom numbers, primarily owing to the great demand of unpredictable, indecipherable cryptographic keys from true random numbers for information security. Thus, far, the sole demonstration of true random numbers has been generated through thermal noise and/or quantum effects, which suffers from expensive and complex equipment. In this paper, we demonstrate a method for self-powered creation of true random numbers by using triboelectric technology to collect random signals from nature. This random number generator based on coupled triboelectric and electrostatic induction effects at the liquid-dielectric interface includes an elaborately designed triboelectric generator (TENG) with an irregular grating structure, an electronic-optical device, and an optical-electronic device. The random characteristics of raindrops are harvested through TENG and consequently transformed and converted by electronic-optical device and an optical-electronic device with a nonlinear characteristic. The cooperation of the mechanical, electrical, and optical signals ensures that the generator possesses complex nonlinear input-output behavior and contributes to increased randomness. The random number sequences are deduced from final electrical signals received by an optical-electronic device using a familiar algorithm. These obtained random number sequences exhibit good statistical characteristics, unpredictability, and unrepeatability. Our study supplies a simple, practical, and effective method to generate true random numbers, which can be widely used in cryptographic protocols, digital signatures, authentication, identification, and other information security fields.

  2. The Neural Border: Induction, Specification and Maturation of the territory that generates Neural Crest cells.

    Science.gov (United States)

    Pla, Patrick; Monsoro-Burq, Anne H

    2018-05-28

    The neural crest is induced at the edge between the neural plate and the nonneural ectoderm, in an area called the neural (plate) border, during gastrulation and neurulation. In recent years, many studies have explored how this domain is patterned, and how the neural crest is induced within this territory, that also participates to the prospective dorsal neural tube, the dorsalmost nonneural ectoderm, as well as placode derivatives in the anterior area. This review highlights the tissue interactions, the cell-cell signaling and the molecular mechanisms involved in this dynamic spatiotemporal patterning, resulting in the induction of the premigratory neural crest. Collectively, these studies allow building a complex neural border and early neural crest gene regulatory network, mostly composed by transcriptional regulations but also, more recently, including novel signaling interactions. Copyright © 2018. Published by Elsevier Inc.

  3. Analysis of non-equilibrium phenomena in inductively coupled plasma generators

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, W.; Panesi, M., E-mail: mpanesi@illinois.edu [University of Illinois at Urbana-Champaign, Urbana, Illinois 61822 (United States); Lani, A. [Von Karman Institute for Fluid Dynamics, Rhode-Saint-Genèse (Belgium)

    2016-07-15

    This work addresses the modeling of non-equilibrium phenomena in inductively coupled plasma discharges. In the proposed computational model, the electromagnetic induction equation is solved together with the set of Navier-Stokes equations in order to compute the electromagnetic and flow fields, accounting for their mutual interaction. Semi-classical statistical thermodynamics is used to determine the plasma thermodynamic properties, while transport properties are obtained from kinetic principles, with the method of Chapman and Enskog. Particle ambipolar diffusive fluxes are found by solving the Stefan-Maxwell equations with a simple iterative method. Two physico-mathematical formulations are used to model the chemical reaction processes: (1) A Local Thermodynamics Equilibrium (LTE) formulation and (2) a thermo-chemical non-equilibrium (TCNEQ) formulation. In the TCNEQ model, thermal non-equilibrium between the translational energy mode of the gas and the vibrational energy mode of individual molecules is accounted for. The electronic states of the chemical species are assumed in equilibrium with the vibrational temperature, whereas the rotational energy mode is assumed to be equilibrated with translation. Three different physical models are used to account for the coupling of chemistry and energy transfer processes. Numerical simulations obtained with the LTE and TCNEQ formulations are used to characterize the extent of non-equilibrium of the flow inside the Plasmatron facility at the von Karman Institute. Each model was tested using different kinetic mechanisms to assess the sensitivity of the results to variations in the reaction parameters. A comparison of temperatures and composition profiles at the outlet of the torch demonstrates that the flow is in non-equilibrium for operating conditions characterized by pressures below 30 000 Pa, frequency 0.37 MHz, input power 80 kW, and mass flow 8 g/s.

  4. Operation strategy for a lab-scale grid-connected photovoltaic generation system integrated with battery energy storage

    International Nuclear Information System (INIS)

    Jou, Hurng-Liahng; Chang, Yi-Hao; Wu, Jinn-Chang; Wu, Kuen-Der

    2015-01-01

    Highlights: • The operation strategy for grid-connected PV generation system integrated with battery energy storage is proposed. • The PV system is composed of an inverter and two DC-DC converter. • The negative impact of grid-connected PV generation systems on the grid can be alleviated by integrating a battery. • The operation of the developed system can be divided into nine modes. - Abstract: The operation strategy for a lab-scale grid-connected photovoltaic generation system integrated with battery energy storage is proposed in this paper. The photovoltaic generation system is composed of a full-bridge inverter, a DC–DC boost converter, an isolated bidirectional DC–DC converter, a solar cell array and a battery set. Since the battery set acts as an energy buffer to adjust the power generation of the solar cell array, the negative impact on power quality caused by the intermittent and unstable output power from a solar cell array is alleviated, so the penetration rate of the grid-connected photovoltaic generation system is increased. A lab-scale prototype is developed to verify the performance of the system. The experimental results show that it achieves the expected performance

  5. Pulsed, Inductively Generated, Streaming Plasma Ion Source for Heavy Ion Fusion Linacs

    International Nuclear Information System (INIS)

    Steven C. Glidden; Howard D Sanders; John B. Greenly; Daniel L. Dongwoo

    2006-01-01

    This report describes a compact, high current density, pulsed ion source, based on electrodeless, inductively driven gas breakdown, developed to meet the requirements on normalized emittance, current density, uniformity and pulse duration for an ion injector in a heavy-ion fusion driver. The plasma source produces >10 (micro)s pulse of Argon plasma with ion current densities >100 mA/cm2 at 30 cm from the source and with strongly axially directed ion energy of about 80 eV, and sub-eV transverse temperature. The source has good reproducibility and spatial uniformity. Control of the current density during the pulse has been demonstrated with a novel modulator coil method which allows attenuation of the ion current density without significantly affecting the beam quality. This project was carried out in two phases. Phase 1 used source configurations adapted from light ion sources to demonstrate the feasibility of the concept. In Phase 2 the performance of the source was enhanced and quantified in greater detail, a modulator for controlling the pulse shape was developed, and experiments were conducted with the ions accelerated to >40 kV

  6. New circuits high-voltage pulse generators with inductive-capacitive energy storage

    International Nuclear Information System (INIS)

    Gordeev, V.S.; Myskov, G.A.

    2001-01-01

    The paper describes new electric circuits of multi-cascade generators based on stepped lines. The distinction of the presented circuits consists in initial storage of energy in electric and magnetic fields simultaneously. The circuit of each generator,relations of impedances,values of initial current and charge voltages are selected in such a manner that the whole of initially stored energy is concentrated at the generator output as a result of transient wave processes. In ideal case the energy is transferred with 100% efficiency to the resistive load where a rectangular voltage pulse is formed, whose duration is equals to the double electrical length of the individual cascade. At the same time there is realized a several time increase of output voltage as compared to the charge voltage of the generator. The use of the circuits proposed makes it possible to ensure a several time increase (as compared to the selection of the number of cascades) of the generator energy storage, pulse current and output electric power

  7. Modeling and Comparison of Power Converters for Doubly Fed Induction Generators in Wind Turbines

    DEFF Research Database (Denmark)

    Helle, Lars

    on the generated power quality and controllability. A consequence of this increased focus has been an ever increased set of requirements formulated in national grid requirement. These requirements has forced wind turbines to evolve from a simple generator on a stick into complicated miniature power plants......During the last decades, renewable energy resources have become an ever increasing part of the world wide power generation and especially energy produced by wind turbines has captured a significant part of this power production. This large penetration of wind power has caused increased focus...... on the design engineers employed in the wind industry. Such a progress may force design engineers to adopt common practice from more or less related technologies rather than finding the optimum solution for the specific application. For instance when applying power electronic converters to wind turbines...

  8. Transient stability with grid connection and wind turbine drive-train effects

    DEFF Research Database (Denmark)

    Fajardo-R, Luis A.; Medina, Aurelio; Iov, Florin

    2009-01-01

    This paper assesses transient stability of grid-connected wind turbines, combining grid-connection, wind turbine flexibility, and induction generator stability features. Through a grid-connected 2 MW wind turbine cage-generator, the investigation is conducted to identify the critical clearing time...

  9. Voltage Control Scheme with Distributed Generation and Grid Connected Converter in a DC Microgrid

    Directory of Open Access Journals (Sweden)

    Jong-Chan Choi

    2014-10-01

    Full Text Available Direct Current (DC microgrids are expected to become larger due to the rapid growth of DC energy sources and power loads. As the scale of the system expends, the importance of voltage control will be increased to operate power systems stably. Many studies have been performed on voltage control methods in a DC microgrid, but most of them focused only on a small scale microgrid, such as a building microgrid. Therefore, a new control method is needed for a middle or large scale DC microgrid. This paper analyzes voltage drop problems in a large DC microgrid and proposes a cooperative voltage control scheme with a distributed generator (DG and a grid connected converter (GCC. For the voltage control with DGs, their location and capacity should be considered for economic operation in the systems. Accordingly, an optimal DG allocation algorithm is proposed to minimize the capacity of a DG for voltage control in DC microgrids. The proposed methods are verified with typical load types by a simulation using MATLAB and PSCAD/EMTDC.

  10. Evaluation small scale, grid connected wind and solar distributed generation systems in Jordan

    International Nuclear Information System (INIS)

    Naji, G. J.; Tahboub, K. K.; Jalham, I. S.

    2011-01-01

    In this paper, the potential of utilizing wind and solar Private Distributed Generation (PDG) for utility interactive systems is investigated for 11 selected stations (sites) in Jordan. Six customer categories are considered: residential, office, commercial mall, school, hospital and hotel. The main goal of this study was to evaluate the potential of utilizing different grid connected PDG under different conditions such as their location, size, served building category, number of people who share and own the equipment and system type whether wind, solar or hybrid based. It was found that solar systems are still not attractive for all location due to their associated high cost, while wind systems would vary widely depending on the customer category, location and the size of the equipment. Based on the Benefit to Cost ratio criterion, the most attractive sites for installing wind PDGS for residential communities are Ras Muneef, Mafraq, Aqaba, Irbid and H5, while it doesn't seem attractive at Amman,Shoubak, Ghor Essafi, Deir Alla, Maan and H4. On the other hand, the wind on-grid PDGS is very attractive at Ras Muneef, mafraq and Aqaba for commercial buildings, less attractive at H5 and irbid, while it's not attractive at the other sites. The attraction for hybrid PDG systems is closer to those of wind systems alone. (authors).

  11. Doubly Fed Induction Generator System Resonance Active Damping through Stator Virtual Impedance

    DEFF Research Database (Denmark)

    Song, Yipeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    (positive capacitor or negative inductor) into the stator branch through stator current feedforward control. The effectiveness of the DFIG system active damping control is verified by a 7.5 kW experimental down-scaled DFIG system, and simulation results of a commercial 2 MW DFIG system is provided as well....... converters/loads. This paper analyzes and explains first the HFR phenomenon between the DFIG system and a parallel compensated weak network (series RL + shunt C). Then on the basis of the DFIG system impedance modeling, an active damping control strategy is introduced by inserting a virtual impedance...... Frequency Resonance (HFR) due to the impedance interaction between the DFIG system and the weak grid network whose impedance is comparative large. Thus, it is important to implement an active damping for the HFR in order to ensure a safe and reliable operation of both the DFIG system and the grid connected...

  12. Induction of oxygen free radical generation in human monocytes by lipoprotein(a)

    DEFF Research Database (Denmark)

    Riis Hansen, P; Kharazmi, A; Jauhiainen, M

    1994-01-01

    The mechanism behind the association of elevated plasma lipoprotein(a) [Lp(a)] levels with atherosclerotic disease is unknown. In the present study, Lp(a) induced generation of oxygen free radicals by monocytes from selected healthy individuals in vitro. This observation may provide a link between...

  13. The Virtual Resistance Control Strategy for HVRT of Doubly Fed Induction Wind Generators Based on Particle Swarm Optimization

    Directory of Open Access Journals (Sweden)

    Zhen Xie

    2014-01-01

    Full Text Available Grid voltage swell will cause transient DC flux component in the doubly fed induction generator (DFIG stator windings, creating serious stator and rotor current and torque oscillation, which is more serious than influence of the voltage dip. It is found that virtual resistance manages effectively to suppress rotor current and torque oscillation, avoid the operation of crowbar circuit, and enhance its high voltage ride through technology capability. In order to acquire the best virtual resistance value, the excellent particle library (EPL of dynamic particle swarm optimization (PSO algorithm is proposed. It takes the rotor voltage and rotor current as two objectives, which has a fast convergence performance and high accuracy. Simulation and experimental results verify the effectiveness of the virtual resistance control strategy.

  14. An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator

    DEFF Research Database (Denmark)

    Yao, J.; Li, H.; Liao, Y.

    2008-01-01

    The paper presents to develop a new control strategy of limiting the dc-link voltage fluctuation for a back-to-back pulsewidth modulation converter in a doubly fed induction generator (DFIG) for wind turbine systems. The reasons of dc-link voltage fluctuation are analyzed. An improved control...... strategy with the instantaneous rotor power feedback is proposed to limit the fluctuation range of the dc-link voltage. An experimental rig is set up to valid the proposed strategy, and the dynamic performances of the DFIG are compared with the traditional control method under a constant grid voltage....... Furthermore, the capabilities of keeping the dc-link voltage stable are also compared in the ride-through control of DFIG during a three-phase grid fault, by using a developed 2 MW DFIG wind power system model. Both the experimental and simulation results have shown that the proposed control strategy is more...

  15. A technical note about Phidel: A new software for evaluating magnetic induction field generated by power lines

    International Nuclear Information System (INIS)

    Comelli, M.; Benes, M.; Bampo, A.; Villalta, R.

    2007-01-01

    The Regional Environment Protection Agency of Friuli Venezia Giulia (ARPA FVG, Italy) has performed an analysis on existing software designed to calculate magnetic induction field generated by power lines. As far as the agency's requirements are concerned the tested programs display some difficulties in the immediate processing of electrical and geometrical data supplied by plant owners, and in certain cases turn out to be inadequate in representing complex configurations of power lines. Phidel, an innovative software, tackles and works out all the above-mentioned problems. Therefore, the obtained results, when compared with those of other programs, are the closest to experimental measurements. The output data can be employed both in the GIS and Excel environments, allowing the immediate overlaying of digital cartography and the determining of the 3 and 10 μT bands, in compliance with the Italian Decree of the President of the Council of Ministers of 8 July 2003. (authors)

  16. Optimal controller design of a doubly fed induction generator wind turbine system for small signal stability enhancement

    DEFF Research Database (Denmark)

    Yang, Lihui; Yang, Guang-Ya; Xu, Zhao

    2010-01-01

    Multi-objective optimal controller design of a doubly-fed induction generator (DFIG) wind turbine system using differential evolution (DE) is presented. A detailed mathematical model of DFIG wind turbine with a closed-loop vector control system is developed. Based on this, objective functions...... and the constraint with DE, respectively. Eigenvalue analysis and time-domain simulations are performed on a single machine infinite bus system as well as a nine-bus multi-machine system with two DFIG wind turbines to illustrate the control performance of the DFIG wind turbine with the optimised controller...... addressing the steady-state stability and dynamic performance at different operating conditions are implemented to optimise the controller parameters of both the rotor and grid-side converters. A superior 1-constraint method and method of adaptive penalties are applied to handle the multi-objective problem...

  17. Semi-automatic determination of tin in marine materials by continuous flow hydride generation inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Feng Yonglai; Narasaki, Hisataki; Chen Hongyuan; Tian Liching

    1997-01-01

    A semi-automated continuous flow hydride generation system with inductively coupled plasma atomic emission spectrometry (ICP-AES) was used for the determination of tin in marine materials. The effects of acids (H 2 SO 4 and HCl) were studied. The analytical parameters were thoroughly investigated. Under optimized conditions, the detection limit is 0.4 ng/ml. Interferences from transition elements were investigated and seven masking reagents were tested. L-cysteine hydrochloride monohydrate (1%) was used to mask the interferences from foreign ions. Finally, the accuracy, checked with a marine standard reference material obtained from the National Research Council (NRC), was within the certified value. (orig.). With 6 figs., 4 tabs

  18. Powerful accelerators for bremsstrahlung and electron beams generation on the basis of inductive energy-storage elements

    Energy Technology Data Exchange (ETDEWEB)

    Diyankov, V S; Kovalev, V P; Kormilitsin, A I; Lavrentev, B N [All-Russian Research Institute of Technical Physics, Snezhinsk (Russian Federation)

    1997-12-31

    The report summarizes RFNC-VNIITF activities from 1963 till 1995, devoted to the development of pulsed electron accelerators on the basis of inductive energy storage with electroexplosive wires. These accelerators are called IGUR. The activities resulted in the development of a series of generators of powerful radiation being cheap and easy in manufacturing and servicing. The accelerators achieved the following maximum parameters: diode voltage up to 6 MV, diode current up to 80 kA, current of the extracted electron beam 30 kA, density of the extracted electron beam energy 500 J/cm{sup 2}, bremsstrahlung dose 250000 Rads, and bremsstrahlung dose rate 10{sup 13} Rads/sec. (author). 3 tabs., 5 figs., 7 refs.

  19. Three-phase short circuit calculation method based on pre-computed surface for doubly fed induction generator

    Science.gov (United States)

    Ma, J.; Liu, Q.

    2018-02-01

    This paper presents an improved short circuit calculation method, based on pre-computed surface to determine the short circuit current of a distribution system with multiple doubly fed induction generators (DFIGs). The short circuit current, injected into power grid by DFIG, is determined by low voltage ride through (LVRT) control and protection under grid fault. However, the existing methods are difficult to calculate the short circuit current of DFIG in engineering practice due to its complexity. A short circuit calculation method, based on pre-computed surface, was proposed by developing the surface of short circuit current changing with the calculating impedance and the open circuit voltage. And the short circuit currents were derived by taking into account the rotor excitation and crowbar activation time. Finally, the pre-computed surfaces of short circuit current at different time were established, and the procedure of DFIG short circuit calculation considering its LVRT was designed. The correctness of proposed method was verified by simulation.

  20. Implementation, Comparison and Application of an Average Simulation Model of a Wind Turbine Driven Doubly Fed Induction Generator

    Directory of Open Access Journals (Sweden)

    Lidula N. Widanagama Arachchige

    2017-10-01

    Full Text Available Wind turbine driven doubly-fed induction generators (DFIGs are widely used in the wind power industry. With the increasing penetration of wind farms, analysis of their effect on power systems has become a critical requirement. This paper presents the modeling of wind turbine driven DFIGs using the conventional vector controls in a detailed model of a DFIG that represents power electronics (PE converters with device level models and proposes an average model eliminating the PE converters. The PSCAD/EMTDC™ (4.6 electromagnetic transient simulation software is used to develop the detailed and the proposing average model of a DFIG. The comparison of the two models reveals that the designed average DFIG model is adequate for simulating and analyzing most of the transient conditions.

  1. Powerful accelerators for bremsstrahlung and electron beams generation on the basis of inductive energy-storage elements

    International Nuclear Information System (INIS)

    Diyankov, V.S.; Kovalev, V.P.; Kormilitsin, A.I.; Lavrentev, B.N.

    1996-01-01

    The report summarizes RFNC-VNIITF activities from 1963 till 1995, devoted to the development of pulsed electron accelerators on the basis of inductive energy storage with electroexplosive wires. These accelerators are called IGUR. The activities resulted in the development of a series of generators of powerful radiation being cheap and easy in manufacturing and servicing. The accelerators achieved the following maximum parameters: diode voltage up to 6 MV, diode current up to 80 kA, current of the extracted electron beam 30 kA, density of the extracted electron beam energy 500 J/cm 2 , bremsstrahlung dose 250000 Rads, and bremsstrahlung dose rate 10 13 Rads/sec. (author). 3 tabs., 5 figs., 7 refs

  2. Cost on Reliability and Production Loss for Power Converters in the Doubly Fed Induction Generator to Support Modern Grid Codes

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede; Lau, Mogens

    2016-01-01

    As wind farms are normally located in remote areas, many grid codes have been issued especially related to the reactive power support. Although the Doubly-Fed Induction Generator (DFIG) based power converter is able to control the active power and reactive power independently, the effects...... of providing reactive power on the lifetime of the power converter and the cost-of-energy of the whole system are seldom evaluated, even though it is an important topic. In this paper, the loss models of the DFIG system are established at various conditions of the reactive power injection. If the mission...... profile is taken into account, the lifespan of the power semiconductors as well as the cost of the reactive power can be calculated. It is concluded that an over-excited reactive power injection significantly reduces the power converter lifetime, only 1/4 of the case that there is no reactive power...

  3. Connection of leak detectors for duplex tube plates of modular steam generator

    International Nuclear Information System (INIS)

    Banovec, J.; Konarik, M.; Vytopil, O.

    1985-01-01

    The sensors are connected to common line and column conductors. This connection significantly reduces the number of evaluation points and thus also the required number of evaluation unit channels. The reliability of the instrument is increased by each sensor being connected to two separate group conductors. Even upon failure of one of the conductors, the group of tube plates can be identified where a leak occurred. (J.B.)

  4. UV-generated free radicals (FR) in skin: Their prevention by sunscreens and their induction by self-tanning agents

    Science.gov (United States)

    Jung, K.; Seifert, M.; Herrling, Th.; Fuchs, J.

    2008-05-01

    In the past few years, the cellular effects of ultraviolet (UV) irradiation induced in skin have become increasingly recognized. Indeed, it is now well known that UV irradiation induces structural and cellular changes in all the compartments of skin tissue. The generation of reactive oxygen species (ROS) is the first and immediate consequence of UV exposure and therefore the quantitative determination of free radical reactions in the skin during UV radiation is of primary importance for the understanding of dermatological photodamage. The RSF method (radical sun protection factor) herein presented, based on electron spin resonance spectroscopy (ESR), enables the measurement of free radical reactions in skin biopsies directly during UV radiation. The amount of free radicals varies with UV doses and can be standardized by varying UV irradiance or exposure time. The RSF method allows the determination of the protective effect of UV filters and sunscreens as well as the radical induction capacity of self-tanning agents as dihydroxyacetone (DHA). The reaction of the reducing sugars used in self-tanning products and amino acids in the skin layer (Maillard reaction) leads to the formation of Amadori products that generate free radicals during UV irradiation. Using the RSF method three different self-tanning agents were analyzed and it was found, that in DHA-treated skin more than 180% additional radicals were generated during sun exposure with respect to untreated skin. For this reason the exposure duration in the sun must be shortened when self-tanners are used and photoaging processes are accelerated.

  5. Active Power Optimal Control of Wind Turbines with Doubly Fed Inductive Generators Based on Model Predictive Control

    Directory of Open Access Journals (Sweden)

    Guo Jiuwang

    2015-01-01

    Full Text Available Because of the randomness and fluctuation of wind energy, as well as the impact of strongly nonlinear characteristic of variable speed constant frequency (VSCF wind power generation system with doubly fed induction generators (DFIG, traditional active power control strategies are difficult to achieve high precision control and the output power of wind turbines is more fluctuated. In order to improve the quality of output electric energy of doubly fed wind turbines, on the basis of analyzing the operating principles and dynamic characteristics of doubly fed wind turbines, this paper proposes a new active power optimal control method of doubly fed wind turbines based on predictive control theory. This method uses state space model of wind turbines, based on the prediction of the future state of wind turbines, moves horizon optimization, and meanwhile, gets the control signals of pitch angle and generator torque. Simulation results show that the proposed control strategies can guarantee the utilization efficiency for wind energy. Simultaneously, they can improve operation stability of wind turbines and the quality of electric energy.

  6. Radiomutation induction of dwarf and semidwarf types of domesticated plants in connection with the effectiveness of gibberellic acid

    International Nuclear Information System (INIS)

    Pozsar, B.

    1979-01-01

    The application of ionizing radiation in plant improvement is reviewed. The intermittant low-dose irradiation of the air-dried seeds increases the rate of dwarf-mutations. This phenomenon was observed in the case of wheat and beans. Dwarfism is constant in the M 1 and M 2 generations, too. Treatment with gibberellinic acid does not alter dwarfism, indicating that irradiation did not only inhibit the synthesis of gibberell ic acid, but induced significant alterations in its action, too. (L.E.)

  7. Comparison of 2D and 3D neural induction methods for the generation of neural progenitor cells from human induced pluripotent stem cells.

    Science.gov (United States)

    Chandrasekaran, Abinaya; Avci, Hasan X; Ochalek, Anna; Rösingh, Lone N; Molnár, Kinga; László, Lajos; Bellák, Tamás; Téglási, Annamária; Pesti, Krisztina; Mike, Arpad; Phanthong, Phetcharat; Bíró, Orsolya; Hall, Vanessa; Kitiyanant, Narisorn; Krause, Karl-Heinz; Kobolák, Julianna; Dinnyés, András

    2017-12-01

    Neural progenitor cells (NPCs) from human induced pluripotent stem cells (hiPSCs) are frequently induced using 3D culture methodologies however, it is unknown whether spheroid-based (3D) neural induction is actually superior to monolayer (2D) neural induction. Our aim was to compare the efficiency of 2D induction with 3D induction method in their ability to generate NPCs, and subsequently neurons and astrocytes. Neural differentiation was analysed at the protein level qualitatively by immunocytochemistry and quantitatively by flow cytometry for NPC (SOX1, PAX6, NESTIN), neuronal (MAP2, TUBB3), cortical layer (TBR1, CUX1) and glial markers (SOX9, GFAP, AQP4). Electron microscopy demonstrated that both methods resulted in morphologically similar neural rosettes. However, quantification of NPCs derived from 3D neural induction exhibited an increase in the number of PAX6/NESTIN double positive cells and the derived neurons exhibited longer neurites. In contrast, 2D neural induction resulted in more SOX1 positive cells. While 2D monolayer induction resulted in slightly less mature neurons, at an early stage of differentiation, the patch clamp analysis failed to reveal any significant differences between the electrophysiological properties between the two induction methods. In conclusion, 3D neural induction increases the yield of PAX6 + /NESTIN + cells and gives rise to neurons with longer neurites, which might be an advantage for the production of forebrain cortical neurons, highlighting the potential of 3D neural induction, independent of iPSCs' genetic background. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  8. Infrared signal generation from AC induction field heating of graphite foam

    Science.gov (United States)

    Klett, James W.; Rios, Orlando

    2018-02-27

    A magneto-energy apparatus includes an electromagnetic field source for generating a time-varying electromagnetic field. A graphite foam conductor is disposed within the electromagnetic field. The graphite foam when exposed to the time-varying electromagnetic field conducts an induced electric current, the electric current heating the graphite foam to produce light. An energy conversion device utilizes light energy from the heated graphite foam to perform a light energy consuming function. A device for producing light and a method of converting energy are also disclosed.

  9. IEEE standard for type test of class 1E electric cables, field splices, and connections for nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1974-01-01

    The Institute of Electrical and Electronics Engineers has generated this document to provide guidance for developing a program to type test cables, field splices, and connections and obtain specific type test data. It supplements IEEE Std 323-1974 Standard for Qualifying Class IE Equipment for Nuclear Power Generating Stations, which describes basic requirements for equipment qualification. It is the integrated performance of the structures, fluid systems, the electrical systems, the instrumentation systems of the station, and in particular, the plant protection system, that limits the consequences of accidents. Seismic effects on installed cable systems are not within the scope of this document. Section 2 of this guide is an example of type tests. It is the purpose of this guide to deal with cable and connections; however, at the time of issue, detailed examples of tests for connections were not available

  10. An electrical dynamo that is a new technology over the generation of electricity by induction

    International Nuclear Information System (INIS)

    Hickox, B.

    1991-01-01

    This invention describes a different device for generating a type alternating electrical power. In the paper an electrical generator is described with one or more nonconductive cylinders mounted for rotation about an axis and containing at lest four pairs of permanent magnets, longitudinally spaced within the cylinder and angularly offset from each other in a helical array. Each of the magnets in each pair is radially disposed in the cylinder opposite the other and separated from the other at the cylinder axis with like poles facing each other. An electrical secondary is provided within the magnetic field of the magnets in the cylinder. A ring magnetic is oriented with an axis parallel to the cylinder axis an is relatively moveable there along. The magnetic fields acting between the ring magnet and the magnets in the cylinder rotates the cylinder to induce electrical current in the generatory secondary. A working model of this device has been constructed and tested. Other researchers are currently building and testing other similar units and various embodiments and applications of this device. This device warrants further testing and closer study

  11. Flapping foil power generator performance enhanced with a spring-connected tail

    Science.gov (United States)

    Liu, Zhengliang; Tian, Fang-Bao; Young, John; Lai, Joseph C. S.

    2017-12-01

    The flexibility effects on the performance of a flapping foil power generator are numerically studied by using the immersed boundary-lattice Boltzmann method at a Reynolds number of 1100. The flapping foil system consists of a rigid NACA0015 foil undergoing harmonic pitch and plunge motions and a passively actuated flat plate pinned to the trailing edge of the rigid foil. The flexibility is modeled by a torsional spring model at the conjuncture of the rigid foil and the tail. Here, a parametric study on mass density and natural frequency is conducted under the optimum kinematic condition of the rigid system identified from the literature and numerical simulations made for reduced frequency f* = 0.04-0.24 and pitch amplitude θ0 = 40°-90°. Four typical cases are discussed in detail by considering time histories of hydrodynamic loads and tail deformations under the optimal and non-optimal kinematic conditions. Results show that under the rigid-system optimal kinematic condition, a tail with appropriate mass density (μ = 0.60) and resonant frequency ( fr*=1.18 ) can improve the maximum efficiency by 7.24% accompanied by an increase of 6.63% in power compared to those of a rigid foil with a rigid tail. This is because the deflection of the tail reduces the low pressure region on the pressure surface (i.e., the lower surface during the upstroke or the upper surface during the downstroke) caused by the leading edge vortex after the stroke reversal, resulting in a higher efficiency. At high flapping frequencies, a spring-connected tail ( fr*=0.13 ) eliminates the large spike in the moment observed in high stiffness cases, reducing the power required for the pitch motion, resulting in 117% improvement in efficiency over that with a rigid tail at a reduced frequency of 0.24.

  12. Renewable Energy Jobs. Status, prospects and policies. Biofuels and grid-connected electricity generation

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, H; Ferroukhi, R [et al.; IRENA Policy Advisory Services and Capacity Building Directorate, Abu Dhabi (United Arab Emirates)

    2012-01-15

    Over the past years, interest has grown in the potential for the renewable energy industry to create jobs. Governments are seeking win-win solutions to the dual challenge of high unemployment and climate change. By 2010, USD 51 billion had been pledged to renewables in stimulus packages, and by early 2011 there were 119 countries with some kind of policy target and/or support policy for renewable energy, such as feed-in tariffs, quota obligations, favourable tax treatment and public loans or grants, many of which explicitly target job creation as a policy goal. Policy-makers in many countries are now designing renewable energy policies that aim to create new jobs, build industries and benefit particular geographic areas. But how much do we know for certain about the job creation potential for renewable energy? This working paper aims to provide an overview of current knowledge on five questions: (1) How can jobs in renewable energy be characterised?; (2) How are they shared out across the technology value chain and what skill levels are required?; (3) How many jobs currently exist and where are they in the world?; (4) How many renewable energy jobs could there be in the future?; and (5) What policy frameworks can be used to promote employment benefits from renewable energy? This paper focuses on grid-connected electricity generation technologies and biofuels. Since the employment potential of off-grid applications is large, it will be covered by a forthcoming study by IRENA on job creation in the context of energy access, based on a number of case studies.

  13. A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support

    Science.gov (United States)

    Shen, Yang-Wu; Ke, De-Ping; Sun, Yuan-Zhang; Daniel, Kirschen; Wang, Yi-Shen; Hu, Yuan-Chao

    2015-07-01

    A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator (DFIG) equipped with a superconducting magnetic energy storage (SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter (GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter (RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive (priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. Project supported by the National Natural Science Foundation of China (Grant No. 51307124) and the Major Program of the National Natural Science Foundation of China (Grant No. 51190105).

  14. Mission profile resolution effects on lifetime estimation of doubly-fed induction generator power converter

    DEFF Research Database (Denmark)

    Zhang, Guanguan; Zhou, Dao; Blaabjerg, Frede

    2017-01-01

    , and the corresponding thermal modeling of power semiconductors are discussed. Accordingly, effects of different mission profiles on the consumed lifetime of the power converter are evaluated. In the above three thermal cycles, the IGBT of the grid-side converter and the diode of the rotor-side converter are more...... fragile, and the total consumed lifetimes are higher. Moreover, the short-term thermal cycles with milliseconds resolution induce the unbalance of the lifetime between the diode and IGBT of the grid-side converter, while thermal cycles with hour, second, and millisecond resolution consumes the similar......In the wind energy generation system, mission profiles are complicated, which range from seconds to years. In order to estimate the consumed lifetime of the power converter, wind speed profiles with the time resolution of 1 hour, 1 second and 0.5 millisecond are studied in this paper...

  15. Optoelectronic properties of Black-Silicon generated through inductively coupled plasma (ICP) processing for crystalline silicon solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Hirsch, Jens, E-mail: J.Hirsch@emw.hs-anhalt.de [Anhalt University of Applied Sciences, Faculty EMW, Bernburger Str. 55, DE-06366 Köthen (Germany); Fraunhofer Center for Silicon Photovoltaics CSP, Otto-Eißfeldt-Str. 12, DE-06120 Halle (Saale) (Germany); Gaudig, Maria; Bernhard, Norbert [Anhalt University of Applied Sciences, Faculty EMW, Bernburger Str. 55, DE-06366 Köthen (Germany); Lausch, Dominik [Fraunhofer Center for Silicon Photovoltaics CSP, Otto-Eißfeldt-Str. 12, DE-06120 Halle (Saale) (Germany)

    2016-06-30

    Highlights: • Fabrication of black silicon through inductively coupled plasma (ICP) processing. • Suppressed formation a self-bias and therefore a reduced ion bombardment of the silicon sample. • Reduction of the average hemispherical reflection between 300 and 1120 nm up to 8% within 5 min ICP process time. • Reflection is almost independent of the angle of incidence up to 60°. • 2.5 ms effective lifetime at 10{sup 15} cm{sup −3} MCD after ALD Al{sub 2}O{sub 3} surface passivation. - Abstract: The optoelectronic properties of maskless inductively coupled plasma (ICP) generated black silicon through SF{sub 6} and O{sub 2} are analyzed by using reflection measurements, scanning electron microscopy (SEM) and quasi steady state photoconductivity (QSSPC). The results are discussed and compared to capacitively coupled plasma (CCP) and industrial standard wet chemical textures. The ICP process forms parabolic like surface structures in a scale of 500 nm. This surface structure reduces the average hemispherical reflection between 300 and 1120 nm up to 8%. Additionally, the ICP texture shows a weak increase of the hemispherical reflection under tilted angles of incidence up to 60°. Furthermore, we report that the ICP process is independent of the crystal orientation and the surface roughness. This allows the texturing of monocrystalline, multicrystalline and kerf-less wafers using the same parameter set. The ICP generation of black silicon does not apply a self-bias on the silicon sample. Therefore, the silicon sample is exposed to a reduced ion bombardment, which reduces the plasma induced surface damage. This leads to an enhancement of the effective charge carrier lifetime up to 2.5 ms at 10{sup 15} cm{sup −3} minority carrier density (MCD) after an atomic layer deposition (ALD) with Al{sub 2}O{sub 3}. Since excellent etch results were obtained already after 4 min process time, we conclude that the ICP generation of black silicon is a promising technique

  16. Generation of ion-acoustic waves in an inductively coupled, low-pressure discharge lamp

    International Nuclear Information System (INIS)

    Camparo, J. C.; Klimcak, C. M.

    2006-01-01

    For a number of years it has been known that the alkali rf-discharge lamps used in atomic clocks can exhibit large amplitude intensity oscillations. These oscillations arise from ion-acoustic plasma waves and have typically been associated with erratic clock behavior. Though large amplitude ion-acoustic plasma waves are clearly deleterious for atomic clock operation, it does not follow that small amplitude oscillations have no utility. Here, we demonstrate two easily implemented methods for generating small amplitude ion-acoustic plasma waves in alkali rf-discharge lamps. Furthermore, we demonstrate that the frequency of these waves is proportional to the square root of the rf power driving the lamp and therefore that their examination can provide an easily accessible parameter for monitoring and controlling the lamp's plasma conditions. This has important consequences for precise timekeeping, since the atomic ground-state hyperfine transition, which is the heart of the atomic clock signal, can be significantly perturbed by changes in the lamp's output via the ac-Stark shift

  17. Proportional-Resonant Control of Doubly-Fed Induction Generator Wind Turbines for Low-Voltage Ride-Through Enhancement

    Directory of Open Access Journals (Sweden)

    Zhan-Feng Song

    2012-11-01

    Full Text Available A novel control strategy is proposed in this paper for the rotor side converter (RSC of doubly-fed induction generator (DFIG-based wind power generation systems. It is supposed to enhance the low-voltage ride-through (LVRT capability of DFIGs during great-level grid voltage dips. The strategy consists of a proportional-resonant (PR controller and auxiliary PR controllers. The auxiliary controllers compensate the output voltage of the RSC in case of grid faults, thus limiting the rotor inrush current of DFIG and meeting the requirements of LVRT. Sequential-component decompositions of current are not required in the control system to improve the response of system. Since the resonant compensator is a double-side integrator, the auxiliary controllers can be simplified through coordinate transformation. The feasibility of the control strategy is validated by simulation on a 1.5 MW wind-turbine driven DFIG system. The impact of the RSC converter voltage rating on the LVRT capability of DFIG is investigated. Meanwhile, the influence of angular frequency detection and control parameters are also discussed. Compared with traditional vector control schemes based on PI current controllers, the presented control strategy effectively suppress rotor current and reduce oscillations of DFIG power and torque under grid faults.

  18. Active-Reactive Additional Damping Control of a Doubly-Fed Induction Generator Based on Active Disturbance Rejection Control

    Directory of Open Access Journals (Sweden)

    Yanfeng Ma

    2018-05-01

    Full Text Available Large-scale wind power interfacing to the power grid has an impact on the stability of the power system. However, with an additional damping controller of the wind generator, new ways for improving system damping and suppressing the low frequency oscillation (LFO of power systems can be put forward. In this paper, an active-reactive power additional damping controller based on active disturbance rejection control (ADRC is proposed. In order to improve the precision of the controller, the theory of data driven control is adopted, using the numerical algorithms for subspace state space system identification (N4SID to obtain the two order model of the ADRC controlled object. Based on the identification model, the ADRC additional damping controller is designed. Taking a 2-area 4-machine system containing the doubly fed induction generator (DFIG wind farm as an example, it is verified that the active-reactive additional damping controller designed in this paper performs well in suppressing negative-damping LFO and forced power oscillation. When the operation state of the power system changes, it can still restrain the LFO effectively, showing stronger robustness and better effectiveness compared to the traditional proportional–integral–derivative (PID additional damping controller.

  19. Tin Content Determination in Canned Fruits and Vegetables by Hydride Generation Inductively Coupled Plasma Optical Emission Spectrometry

    Directory of Open Access Journals (Sweden)

    Sanda Rončević

    2012-01-01

    Full Text Available Tin content in samples of canned fruits and vegetables was determined by hydride generation inductively coupled plasma atomic emission spectrometry (HG-ICP-OES, and it was compared with results obtained by standard method of flame atomic absorption spectrometry (AAS. Selected tin emission lines intensity was measured in prepared samples after addition of tartaric acid and followed by hydride generation with sodium borohydride solution. The most favorable line at 189.991 nm showed the best detection limit (1.9 μg L−1 and limit of quantification (6.4 μg kg−1. Good linearity and sensitivity were established from time resolved analysis and calibration tests. Analytical accuracy of 98–102% was obtained by recovery study of spiked samples. Method of standard addition was applied for tin determination in samples from fully protected tinplate. Tin presence at low-concentration range was successfully determined. It was shown that tenth times less concentrations of Sn were present in protected cans than in nonprotected or partially protected tinplate.

  20. Automatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection

    Directory of Open Access Journals (Sweden)

    M. Kasagi

    2016-02-01

    Full Text Available A base-isolated building may sometimes exhibit an undesirable large response to a long-duration, long-period earthquake ground motion and a connected building system without base-isolation may show a large response to a near-fault (rather high-frequency earthquake ground motion. To overcome both deficiencies, a new hybrid control system of base-isolation and building-connection is proposed and investigated. In this new hybrid building system, a base-isolated building is connected to a stiffer free wall with oil dampers. It has been demonstrated in a preliminary research that the proposed hybrid system is effective both for near-fault (rather high-frequency and long-duration, long-period earthquake ground motions and has sufficient redundancy and robustness for a broad range of earthquake ground motions.An automatic generation algorithm of this kind of smart structures of base-isolation and building-connection hybrid systems is presented in this paper. It is shown that, while the proposed algorithm does not work well in a building without the connecting-damper system, it works well in the proposed smart hybrid system with the connecting damper system.

  1. In-duct countermeasures for reducing fire-generated-smoke-aerosol exposure to HEPA filters

    International Nuclear Information System (INIS)

    Alvares, N.J.; Beason, D.G.; Ford, H.W.

    1978-01-01

    An experimental program was conducted to assess the endurance and lifetime of HEPA filters exposed to fire-generated aerosols, and to reduce the aerosol exposure by installing engineering countermeasures in the duct between the fire source and HEPA filters. Large cribs of wood and other potential fuels of interest were ''forcefully burned'' in a partially ventilated enclosure. In a ''forceful burn'' the crib of fuel is continuously exposed to an energetic premixed methane flame during the entire experimental period. This tactic serves two purposes: it optimizes the production of smoke rich in unburned pyrolyzates which provides severe exposure to the filters, and it facilitates the ignition and enhances the combustion of cribs formed with synthetic polymers. The experiments were conducted in an enclosure specifically designed and instrumented for fire tests. The test cell has a volume of 100 m 3 and includes instrumentation to measure the internal temperature distribution, pressure, thermal radiation field, flow fields, gas concentration, particulate size distribution and mass, fuel weight loss, inlet and exit air velocities, and smoke optical density. The countermeasure techniques include the use of passively operated sprinkler systems in the fire test cell, of fine and dense water scrubbing sprays, and of rolling prefiltration systems in the exit duct of the fire test cell. Of the countermeasures surveyed, the rolling prefilter system showed the most promise. This paper concentrates on the effect of control variables; i.e., enclosure air supply, fuel composition and crib porosity on the combustion response; i.e., crib burning rate, enclosure temperature rise, oxygen consumption, and CO, CO 2 and total hydrocarbon production. A discussion of the attempts to rationalize smoke aerosol properties will be included along with results from the effect of countermeasure application on HEPA filter lifetimes

  2. Connecting device for external ends of steam generator anti-vibration bars

    International Nuclear Information System (INIS)

    Boula, G.; Roinjard, J.P.

    1990-01-01

    The connexion device comprises a support that is fixed over the external end of an antivibration bar with a tap aperture and a connexion arm fixed to it on one extremity and one the other end to a sleeve with a connecting screw. The connecting screw engages through the bore of the sleeve into an opening in the adjacent support fixed over a second antivibration bar [fr

  3. Comparative Study of Modulation-Based Individual Inverter Techniques for Direct and Inverse by using Star-Connection Induction Motor in Extra Low Voltage Application

    Directory of Open Access Journals (Sweden)

    Ardhia Wishnuprakasa

    2016-12-01

    Full Text Available In this study, the IEEE 519 Standard as a basis benchmarking for voltage (THDV and current (THDI in draft performance. Comparative Study based onthree-techniques of 2-Level Converter (2LC by using a Star-Connection Induction Motor (Y-CIM in ExtraLow Voltage (ELV Configuration.For the detail explanation, a primary inverter as Direct-Inverterby PWMdirect (PWM degreesand asecondary inverter as Inverse-Inverterby PWMinverse(PWM + PI degrees. It tends a modified algorithm,for eachof SPWM in six rules, and FHIPWM in 5th harmonics Injectedin standard modulation as the purpose for the Open-Ends of Pre-Dual Inverter in Decoupled SPWM for twelve rules, and Decoupled FHIPWM in combination of 5th harmonics Injectedin combination of two-standard-modulation. Those techniques are the purpose of two-inverter combination, which namelythe Equal Direct-Inverse (EDI algorithmproduct of prototyping in similarities. The observation is restricted in voltage scope between Simulation by using Power Simulator (PSIMand Application by using Microcontroller ARM STM32F4 Discovery.

  4. Modal analysis of a grid-connected direct-drive permanent magnet synchronous generator wind turbine system

    DEFF Research Database (Denmark)

    Tan, Jin; Wang, Xiao Ru; Chen, Zhe

    2013-01-01

    In order to study the stability of a grid-connected direct-drive permanent magnet synchronous generator (PMSG) wind turbine systems, this paper presents the modal analysis of a PMSG wind turbine system. A PMSG model suitable for small signal stability analysis is presented. The modal properties...... of a grid-connected PMSG wind turbine system are studied. Then the comprehensive impacts of the shaft model, shaft parameters, operation points and lengths of the transmission line on the modal characteristic of the system are investigated by the eigenvalue analysis method. Meanwhile, the corresponding...... analysis. It offers a better understanding about the essence of the stability of grid-connected PMSG wind turbine system....

  5. 0D modelling and efficiency analysis of three power amplification schemes for inductive storage generators in the μs scale

    International Nuclear Information System (INIS)

    Huet, D.; Lassalle, F.; Chuvatin, A.S.

    2005-01-01

    Extensive studies were conducted to sharpen current pulse on IES (Inductive Energy Storage) drivers using the plasma opening switch scheme. Due to the emergence of new power amplification concepts, new opportunities appear for improving IES generators operation. In order to evaluate and compare the performances of these schemes this paper proposes a system analysis based on a 0D modelling [ru

  6. The Importance of Lateral Connections in the Parietal Cortex for Generating Motor Plans.

    Directory of Open Access Journals (Sweden)

    Derrik E Asher

    Full Text Available Substantial evidence has highlighted the significant role of associative brain areas, such as the posterior parietal cortex (PPC in transforming multimodal sensory information into motor plans. However, little is known about how different sensory information, which can have different delays or be absent, combines to produce a motor plan, such as executing a reaching movement. To address these issues, we constructed four biologically plausible network architectures to simulate PPC: 1 feedforward from sensory input to the PPC to a motor output area, 2 feedforward with the addition of an efference copy from the motor area, 3 feedforward with the addition of lateral or recurrent connectivity across PPC neurons, and 4 feedforward plus efference copy, and lateral connections. Using an evolutionary strategy, the connectivity of these network architectures was evolved to execute visually guided movements, where the target stimulus provided visual input for the entirety of each trial. The models were then tested on a memory guided motor task, where the visual target disappeared after a short duration. Sensory input to the neural networks had sensory delays consistent with results from monkey studies. We found that lateral connections within the PPC resulted in smoother movements and were necessary for accurate movements in the absence of visual input. The addition of lateral connections resulted in velocity profiles consistent with those observed in human and non-human primate visually guided studies of reaching, and allowed for smooth, rapid, and accurate movements under all conditions. In contrast, Feedforward or Feedback architectures were insufficient to overcome these challenges. Our results suggest that intrinsic lateral connections are critical for executing accurate, smooth motor plans.

  7. Sb(III) and Sb(V) separation and analytical speciation by a continuous tandem on-line separation device in connection with inductively coupled plasma atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Menendez Garcia, A. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Perez Rodriguez, M.C. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Sanchez Uria, J.F. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.; Sanz-Medel, A. [Oviedo Univ. (Spain). Dept. of Phys. and Anal. Chem.

    1995-09-01

    A sensitive, precise and automated non-chromatographic method for Sb(III) and Sb(V) analytical speciation based on a continuous tandem on-line separation device in connection with inductively coupled plasma-atomic emission (ICP-AES) detection is proposed. Two on-line successive separation steps are included into this method: a continuous liquid-liquid extraction of Sb(III) with ammonium pyrrolidine dithiocarbamate (APDC) into methylisobuthylketone (MIBK), followed by direct stibine generation from the organic phase. Both separation steps are carried out in a continuous mode and on-line with the ICP-AES detector. Optimization of experimental conditions for the tandem separation and ICP-AES detection are investigated in detail. Detection limits for Sb(III) were 3 ng.mL{sup -1} and for Sb(V) 8 ng.mL{sup -1}. Precisions observed are in the range {+-} 5%. The proposed methodology has been applied to Sb(III) and Sb(V) speciation in sea-water samples. (orig.)

  8. Dynamic modeling of wind turbine based axial flux permanent magnetic synchronous generator connected to the grid with switch reduced converter

    Directory of Open Access Journals (Sweden)

    Ali Reza Dehghanzadeh

    2018-03-01

    Full Text Available This paper studies the power electronic converters for grid connection of axial flux permanent magnetic synchronous generators (AFPMSG based variable speed wind turbine. In this paper, a new variable speed wind turbine with AFPMSG and Z-source inverter is proposed to improve number of switches and topology reliability. Besides, dynamic modeling of AFPMSG is presented to analyze grid connection of the proposed topology. The Z-source inverter controls maximum power point tracking (MPPT and delivering power to the grid. Therefore other DC–DC chopper is not required to control the rectified output voltage of generator in view of MPPT. As a result, the proposed topology requires less power electronic switches and the suggested system is more reliable against short circuit. The ability of proposed energy conversion system with AFPMSG is validated with simulation results and experimental results using PCI-1716 data acquisition system.

  9. Robust fractional order sliding mode control of doubly-fed induction generator (DFIG)-based wind turbines.

    Science.gov (United States)

    Ebrahimkhani, Sadegh

    2016-07-01

    Wind power plants have nonlinear dynamics and contain many uncertainties such as unknown nonlinear disturbances and parameter uncertainties. Thus, it is a difficult task to design a robust reliable controller for this system. This paper proposes a novel robust fractional-order sliding mode (FOSM) controller for maximum power point tracking (MPPT) control of doubly fed induction generator (DFIG)-based wind energy conversion system. In order to enhance the robustness of the control system, uncertainties and disturbances are estimated using a fractional order uncertainty estimator. In the proposed method a continuous control strategy is developed to achieve the chattering free fractional order sliding-mode control, and also no knowledge of the uncertainties and disturbances or their bound is assumed. The boundedness and convergence properties of the closed-loop signals are proven using Lyapunov׳s stability theory. Simulation results in the presence of various uncertainties were carried out to evaluate the effectiveness and robustness of the proposed control scheme. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Adaptive Droop Control Applied to Distributed Generation Inverters Connected to the Grid

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Teodorescu, Remus; Vásquez, Juan C.

    2008-01-01

    This paper proposes a novel control for voltage source inverters connected to the grid. The control scheme is based on the droop method, and it uses some estimated variables from the grid such as the voltage and the frequency, and the magnitude and angle of the grid impedance. Hence, the inverter...

  11. Benchmarking of Constant Power Generation Strategies for Single-Phase Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    With a still increase of grid-connected Photovoltaic (PV) systems, challenges have been imposed on the grid due to the continuous injection of a large amount of fluctuating PV power, like overloading the grid infrastructure (e.g., transformers) during peak power production periods. Hence, advanced...

  12. Type test of Class 1E electric cables, field splices, and connections for nuclear power generating stations - 1975

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    This Standard provides direction for establishing type tests which may be used in qualifying Class 1E electric cables, field splices, and other connections for service in nuclear power generating stations. General guidelines for qualifications are given in IEEE Std 323-1974, Standard for Qualifying Class 1E Electric Equipment for Nuclear Power Generating Stations. Categories of cables covered are those used for power control and instrumentation services. Though intended primarily to pertain to cable for field installation, this guide may also be used for the qualification of internal wiring of manufactured devices

  13. Wind generator based on cascade connection of two asynchronized synchronous machines

    International Nuclear Information System (INIS)

    Dzhagarov, N.; Dzhagarova, Yu.

    2000-01-01

    A model of a wind generator with two asynchronized synchronous machines presented and different regimes are investigated. The analysis shows that the suggested scheme of a brushless generator works and has more advantages (reliability, easy for operation) in comparison with the known ones

  14. Variation in habitat connectivity generates positive correlations between species and genetic diversity in a metacommunity.

    Science.gov (United States)

    Lamy, T; Jarne, P; Laroche, F; Pointier, J-P; Huth, G; Segard, A; David, P

    2013-09-01

    An increasing number of studies are simultaneously investigating species diversity (SD) and genetic diversity (GD) in the same systems, looking for 'species- genetic diversity correlations' (SGDCs). From negative to positive SGDCs have been reported, but studies have generally not quantified the processes underlying these correlations. They were also mostly conducted at large biogeographical scales or in recently degraded habitats. Such correlations have not been looked for in natural networks of connected habitat fragments (metacommunities), and the underlying processes remain elusive in most systems. We investigated these issues by studying freshwater snails in a pond network in Guadeloupe (Lesser Antilles). We recorded SD and habitat characteristics in 232 ponds and assessed GD in 75 populations of two species. Strongly significant and positive SGDCs were detected in both species. Based on a decomposition of SGDC as a function of variance-covariance of habitat characteristics, we showed that connectivity (opportunity of water flow between a site and the nearest watershed during the rainy season) has the strongest contribution on SGDCs. More connective sites received both more alleles and more species through immigration resulting in both higher GD and higher SD. Other habitat characteristics did not contribute, or contributed negatively, to SGDCs. This is true of the desiccation frequency of ponds during the dry season, presumably because species markedly differ in their ability to tolerate desiccation. Our study shows that variation in environmental characteristics of habitat patches can promote SGDCs at metacommunity scale when the studied species respond homogeneously to these environmental characteristics. © 2013 John Wiley & Sons Ltd.

  15. Control voltage of the generator of auto-excited induction for applications on micro/mini generation o electric power; Control de voltaje del generador de induccion auto-excitado para aplicaciones de micro/mini generacion de energia electrica

    Energy Technology Data Exchange (ETDEWEB)

    Torres Montalvo, Emmanuel

    2006-09-15

    Although only one part of the mini/micro hydraulic power has been exploited in our country, this type of electric energy generation can be considered as a visible way of electricity generation, mainly related to the ecological, economical and social aspects. The impact that these power plants can have in the regions in which they are installed is always positive: cost energy cost reduction, economical spills and mainly a social welfare. The electric energy is one of the pillars for the economical development of a country and provides a better life quality. Nowadays the research and the technology oriented to the operation and control of the micro/mini power plants has awaken the interest of many researchers in several countries of the world as China, India, Canada, and USA to mention some of them. The induction generator plays a crucial role in the uses of these technologies. The work of Basset and Potter in 1935 is the angular stone over the possibility of generating energy making use of the induction machine and a capacitors bank connected to the machine terminals. This configuration is known as induction auto-excited generator (GIAE). Several investigations have been realized that deal about the functioning principle and the dynamic behavior a GIAE, which can supply electric power in remote isolated regions. In the existing literature have been proposed control strategies to offer voltage regulations and/or frequency into the acceptable range. Some of these control strategies present problems such a demand of a reactive power, harmonics injections in the system, the control circuits are complicated, expensive and voluminous and prone to fail. This paper realizes an analysis of the necessary and sufficient conditions so that an induction machine can operate as GIAE. The corresponding curves are presented for each studied case. The dynamic behavior of the voltage and the frequency generated by the GIAE are studied in detail, which is a contribution to the existing

  16. Dynamic model of Stirling engine crank mechanism with connected electric generator

    Directory of Open Access Journals (Sweden)

    Vlach R.

    2009-06-01

    Full Text Available This paper treats of a numerical dynamic model of Stirling engine crank mechanism. The model is included in the complex model of combined heat and power unit. The unit is composed of the Stirling engine and of attached three-phase synchronous generator. This generator should start the Stirling engine in motor mode as well. It is necessary to combine the crank shaft dynamic model and the complete thermal model of Stirling engine for simulations and analyses of engine run. Our aim is to create a dynamics model which takes into account the parameters of crankshaft, piston rods, pistons, and attached generator. For unit working, the electro-mechanical behaviour of generator is also important. That is why we experimentally verified the parameters of generator. The measured characteristics are used in a complex model of heat and power unit. Moreover, it is also possible to determine the Stirling engine torque by the help of these electro-mechanical characteristics. These values can be used e. g. for determination of optimal engine working point or for unit control.

  17. Design and Implementation of Improved Electronic Load Controller for Self-Excited Induction Generator for Rural Electrification

    Directory of Open Access Journals (Sweden)

    C. Kathirvel

    2015-01-01

    Full Text Available This paper offers an alternative technique, namely, Improved Electronic Load Controller (IELC, which is proposal to improve power quality, maintaining voltage at frequency desired level for rural electrification. The design and development of IELC are considered as microhydroenergy system. The proposed work aims to concentrate on the new schemes for rural electrification with the help of different kinds of hybrid energy systems. The objective of the proposed scheme is to maintain the speed of generation against fluctuating rural demand. The Electronic Load Controller (ELC is used to connect and disconnect the dump load during the operation of the system, and which absorbs the load when consumer are not in active will enhance the lifestyle of the rural population and improve the living standards. Hydroelectricity is a promising option for electrification of remote villages in India. The conventional methods are not suitable to act as standalone system. Hence, the designing of a proper ELC is essential. The improved electronic load control performance tested with simulation at validated through hardware setup.

  18. Design and Implementation of Improved Electronic Load Controller for Self-Excited Induction Generator for Rural Electrification.

    Science.gov (United States)

    Kathirvel, C; Porkumaran, K; Jaganathan, S

    2015-01-01

    This paper offers an alternative technique, namely, Improved Electronic Load Controller (IELC), which is proposal to improve power quality, maintaining voltage at frequency desired level for rural electrification. The design and development of IELC are considered as microhydroenergy system. The proposed work aims to concentrate on the new schemes for rural electrification with the help of different kinds of hybrid energy systems. The objective of the proposed scheme is to maintain the speed of generation against fluctuating rural demand. The Electronic Load Controller (ELC) is used to connect and disconnect the dump load during the operation of the system, and which absorbs the load when consumer are not in active will enhance the lifestyle of the rural population and improve the living standards. Hydroelectricity is a promising option for electrification of remote villages in India. The conventional methods are not suitable to act as standalone system. Hence, the designing of a proper ELC is essential. The improved electronic load control performance tested with simulation at validated through hardware setup.

  19. Cited2 Regulates Neocortical Layer II/III Generation and Somatosensory Callosal Projection Neuron Development and Connectivity.

    Science.gov (United States)

    Fame, Ryann M; MacDonald, Jessica L; Dunwoodie, Sally L; Takahashi, Emi; Macklis, Jeffrey D

    2016-06-15

    The neocortex contains hundreds to thousands of distinct subtypes of precisely connected neurons, allowing it to perform remarkably complex tasks of high-level cognition. Callosal projection neurons (CPN) connect the cerebral hemispheres via the corpus callosum, integrating cortical information and playing key roles in associative cognition. CPN are a strikingly diverse set of neuronal subpopulations, and development of this diversity requires precise control by a complex, interactive set of molecular effectors. We have found that the transcriptional coregulator Cited2 regulates and refines two stages of CPN development. Cited2 is expressed broadly by progenitors in the embryonic day 15.5 subventricular zone, during the peak of superficial layer CPN birth, with a progressive postmitotic refinement in expression, becoming restricted to CPN of the somatosensory cortex postnatally. We generated progenitor-stage and postmitotic forebrain-specific Cited2 conditional knock-out mice, using the Emx1-Cre and NEX-Cre mouse lines, respectively. We demonstrate that Cited2 functions in progenitors, but is not necessary postmitotically, to regulate both (1) broad generation of layer II/III CPN and (2) acquisition of precise area-specific molecular identity and axonal/dendritic connectivity of somatosensory CPN. This novel CPN subtype-specific and area-specific control from progenitor action of Cited2 adds yet another layer of complexity to the multistage developmental regulation of neocortical development. This study identifies Cited2 as a novel subtype-specific and area-specific control over development of distinct subpopulations within the broad population of callosal projection neurons (CPN), whose axons connect the two cerebral hemispheres via the corpus callosum (CC). Currently, how the remarkable diversity of CPN subtypes is specified, and how they differentiate to form highly precise and specific circuits, are largely unknown. We found that Cited2 functions within

  20. Generation and detection of spin polarization in parallel coupled double quantum dots connected to four terminals

    International Nuclear Information System (INIS)

    An, Xing-Tao; Mu, Hui-Ying; Li, Yu-Xian; Liu, Jian-Jun

    2011-01-01

    A four-terminal parallel double quantum dots (QDs) device is proposed to generate and detect the spin polarization in QDs. It is found that the spin accumulation in QDs and the spin-polarized currents in the upper and down leads can be generated when a bias voltage is applied between the left and right leads. It is more interesting that the spin polarization in the QDs can be detected using the upper and down leads. Moreover, the direction and magnitude of the spin polarization in the QDs, and in the upper and down leads can be tuned by the energy levels of QDs and the bias. -- Highlights: → The spin polarization in the quantum dots can be generated and controlled. → The spin polarization in quantum dots can be detected by the nonferromagnetic leads. → The system our studied is a discrete level spin Hall system.

  1. Generation and Demand Scheduling for a Grid-Connected Hybrid Microgrid Considering Price-based Incentives

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Savaghebi, Mehdi

    2017-01-01

    Microgrids rely on energy management levels to optimally schedule their components. Conventionally, the research in this field has been focused on the optimal formulation of the generation or the demand side management separately without considering real case scenarios and validated only...... by simulation. This paper presents the power scheduling of a real site microgrid under a price-based demand response program defined in Shanghai, China managing generation and demand simultaneously. The proposed optimization problem aims to minimize operating cost by managing renewable energy sources as well...

  2. A connection of the steam generator feedwater section of WWER type nuclear power plants

    International Nuclear Information System (INIS)

    Matal, O.; Sadilek, J.

    1989-01-01

    In the feedwater piping of each steam generator, a plate for additional water pressure reduction is inserted before the first closing valve. During a steady water flow, the plate gives rise to a constant hydraulic resistance, bringing about steady reduction of the feedwater pressure; this also contributes to a stabilization of the feedwater flow rate into the steam generator. The control valve thus is stressed by minimal hydrodynamic forces. In this manner its load is decreased, its vibrations are damped, and the frequency of failures - and thereby the frequency of the nuclear power plant unit outages -is reduced. (J.P.). 1 fig

  3. Modeling and simulation of grid connected permanent magnet generator based small wind energy conversion systems

    Energy Technology Data Exchange (ETDEWEB)

    Arifujjaman, Md.

    2011-07-01

    In order to recover the maximum energy from small scale wind turbine systems many parameters have to be controlled. The aim of this paper is to propose a control strategy for the grid connected PMG-based small wind turbine systems. A mathematical model of small wind turbine systems was developed and the system simulated. Results show demonstrated that the control strategy is highly efficient. Sure enough it reduces the dependence on system variables, diminishes the system complexity, its furling and maximum power point controllers are efficient and it provides a stable operation for multiple wind speeds. This study developed a modeling and control strategy which was proved to be feasible by simulation results.

  4. Benchmarking of Constant Power Generation Strategies for Single-Phase Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2018-01-01

    strategies based on: 1) a power control method (P-CPG), 2) a current limit method (I-CPG) and 3) the Perturb and Observe algorithm (P&O-CPG). However, the operational mode changes (e.g., from the maximum power point tracking to a CPG operation) will affect the entire system performance. Thus, a benchmarking...... of the presented CPG strategies is also conducted on a 3-kW single-phase grid-connected PV system. Comparisons reveal that either the P-CPG or I-CPG strategies can achieve fast dynamics and satisfactory steady-state performance. In contrast, the P&O-CPG algorithm is the most suitable solution in terms of high...

  5. QCD in a nonsimply connected spacetime: The topological origin of flavours and topological gluon mass generation

    International Nuclear Information System (INIS)

    Goncharov, Yu.P.

    1982-01-01

    In a spacetime having a nontrivial topology QCD may have properties which are absent for QCD in Minkowski spacetime. Two new possibilities for QCD are discussed by the example of spacetime with topology R x (S 1 ) 3 and flat metric: the topological origin of flavours and topological gluon mass generation. (orig.)

  6. Phase-only SLM Generating Variable Patterns Applied in Optical Connection

    International Nuclear Information System (INIS)

    Liu, B H; Wu, L Y; Zhang, J

    2006-01-01

    An adaptive optical communication system is proposed. The system sends spatial information by emitting multiple variable laser beams generated from a programmable diffractive optical element (DOE): phase-only liquid crystal Spatial Light Modulator (SLM). Laser beams carrying signals are programmable by an optimal algorithm based on an iterative Fourier transformation algorithm. The system has the advantage in redundancy of signal by the means of broadcast. It can adaptively seek position and transmit information in parallel

  7. Maximum generation power evaluation of variable frequency offshore wind farms when connected to a single power converter

    Energy Technology Data Exchange (ETDEWEB)

    Gomis-Bellmunt, Oriol; Sumper, Andreas [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Universitat Politecnica de Catalunya UPC, Av. Diagonal, 647, Pl. 2, 08028 Barcelona (Spain); IREC Catalonia Institute for Energy Research, Barcelona (Spain); Junyent-Ferre, Adria; Galceran-Arellano, Samuel [Centre d' Innovacio Tecnologica en Convertidors Estatics i Accionaments (CITCEA-UPC), Universitat Politecnica de Catalunya UPC, Av. Diagonal, 647, Pl. 2, 08028 Barcelona (Spain)

    2010-10-15

    The paper deals with the evaluation of power generated by variable and constant frequency offshore wind farms connected to a single large power converter. A methodology to analyze different wind speed scenarios and system electrical frequencies is presented and applied to a case study, where it is shown that the variable frequency wind farm concept (VF) with a single power converter obtains 92% of the total available power, obtained with individual power converters in each wind turbine (PC). The PC scheme needs multiple power converters implying drawbacks in terms of cost, maintenance and reliability. The VF scheme is also compared to a constant frequency scheme CF, and it is shown that a significant power increase of more than 20% can be obtained with VF. The case study considers a wind farm composed of four wind turbines based on synchronous generators. (author)

  8. FY 2000 report on the demonstrative research for photovoltaic power generation system in Thailand. Demonstrative study on photovoltaic power generation grid-connected system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-09-01

    In relation to the demonstrative study of the photovoltaic power system that is planned in Libong island, Thailand, the FY 2000 results were reported. In this R and D, construction/demonstrative operation were planned for a photovoltaic power station with a generation output of 100kW, photovoltaic power system in school facilities, and system for transmitting/distributing power to houses by connecting the power station and power system. In this fiscal year, the field survey was conducted together with the alteration from Yao Yai island, for which the demonstrative study was planned at first, to Libong island. The electric equipment was selected which met the requests from Thailand and the results of the field survey, and the basic design of the photovoltaic power generation/transmission/distribution system was completed. Based on this, the design/manufacture of photovoltaic power generation modules, power control equipment, measuring equipment, etc. were made. At the construction site of photovoltaic power station, construction work such as land formation was conducted. Further, Thai engineers who visited Japan did the following: discussions about power system, presence at test/inspection of photovoltaic power generation modules, visits to photovoltaic power stations, wind power stations, etc. (NEDO)

  9. Ecumenical movement for millennials: A generation connected but not yet united

    Directory of Open Access Journals (Sweden)

    Yolanda Pantou

    2017-11-01

    Full Text Available In this article the notion ‘ecumenism’ is defined as a connecting movement of reconciling diversity, and the focus is on young people, referred to as ‘millennials’ living in the present-day global village. It addresses the youth’s interests or disinterests in the ‘institutionalised’ ecumenical movement. The following aspects are reflected upon: how ecumenism speaks to the youth; how ecumenism does not speak to the youth; and how to make ecumenism great again for the youth. It discusses young people’s perspectives on the world with regard to religion and tradition, sources of authority, issues of segregation and discrimination, ‘nomadic’ and a mentality which causes that one cannot expect them to stay in one church from baptism until death. The article reflects on the youth’s disposition to human realities concerning aspects such as the ecological crisis, global inequality, religious fundamentalism, violence and oppression, and the lack of a sense of belonging. The article concludes with some initiatives of the World Council of Churches to which young people can make a contribution.

  10. Use of oxidative and reducing vapor generation for reducing the detection limits of iodine in biological samples by inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Vtorushina, Eh.A.; Saprykin, A.I.; Knapp, G.

    2009-01-01

    Procedures of microwave combustion in an oxygen flow and microwave acid decomposition of biological samples were optimized for the subsequent determination of iodine. A new method was proposed for the generation of molecular iodine from periodate iona using hydrogen peroxide as a reductant. Procedures were developed for determining iodine in biological samples by inductively coupled plasma atomic emission spectrometry (ICP-AES) using oxidative and reducing vapor generation; these allowed the detection limit for iodine to be lowered by 3-4 orders of magnitude. The developed procedures were used to analyze certified reference materials of milk (Skim Milk Powder BCR 150) and seaweed (Sea Lettuce BCR 279) and a Supradyn vitamin complex

  11. Borehole induction coil transmitter

    Science.gov (United States)

    Holladay, Gale; Wilt, Michael J.

    2002-01-01

    A borehole induction coil transmitter which is a part of a cross-borehole electromagnetic field system that is used for underground imaging applications. The transmitter consists of four major parts: 1) a wound ferrite or mu-metal core, 2) an array of tuning capacitors, 3) a current driver circuit board, and 4) a flux monitor. The core is wound with several hundred turns of wire and connected in series with the capacitor array, to produce a tuned coil. This tuned coil uses internal circuitry to generate sinusoidal signals that are transmitted through the earth to a receiver coil in another borehole. The transmitter can operate at frequencies from 1-200 kHz and supplies sufficient power to permit the field system to operate in boreholes separated by up to 400 meters.

  12. Life cycle assessment of grid-connected photovoltaic power generation from crystalline silicon solar modules in China

    International Nuclear Information System (INIS)

    Hou, Guofu; Sun, Honghang; Jiang, Ziying; Pan, Ziqiang; Wang, Yibo; Zhang, Xiaodan; Zhao, Ying; Yao, Qiang

    2016-01-01

    Graphical abstract: Comparison of life cycle GHG emissions of various power sources. - Highlights: • The LCA study of grid-connected PV generation with silicon solar modules in China has been performed. • The energy payback times range from 1.6 to 2.3 years. • The GHG emissions are in the range of 60.1–87.3 g-CO_2,eq/kW h. • The PV manufacturing process occupied about 85% or higher of total energy usage and total GHG emission. • The SoG-Si production process accounted for more than 35% of total energy consumption and GHG emissions. - Abstract: The environmental impacts of grid-connected photovoltaic (PV) power generation from crystalline silicon (c-Si) solar modules in China have been investigated using life cycle assessment (LCA). The life cycle inventory was first analyzed. Then the energy consumption and greenhouse gas (GHG) emission during every process were estimated in detail, and finally the life-cycle value was calculated. The results showed that the energy payback time (T_E_P_B_T) of grid-connected PV power with crystalline silicon solar modules ranges from 1.6 to 2.3 years, while the GHG emissions now range from 60.1 to 87.3 g-CO_2,eq/kW h depending on the installation methods. About 84% or even more of the total energy consumption and total GHG emission occupied during the PV manufacturing process. The solar grade silicon (SoG-Si) production is the most energy-consuming and GHG-emitting process, which accounts for more than 35% of the total energy consumption and the total GHG emission. The results presented in this study are expected to provide useful information to enact reasonable policies, development targets, as well as subsidies for PV technology in China.

  13. High-Performance Constant Power Generation in Grid-Connected PV Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    An advanced power control strategy by limiting the maximum feed-in power of PV systems has been proposed, which can ensure a fast and smooth transition between maximum power point tracking and Constant Power Generation (CPG). Regardless of the solar irradiance levels, high-performance and stable...... operation are always achieved by the proposed control strategy. It can regulate the PV output power according to any set-point, and force the PV systems to operate at the left side of the maximum power point without stability problems. Experimental results have verified the effectiveness of the proposed CPG...

  14. The PWM strategies of grid-connected distributed generation active NPC inverters

    DEFF Research Database (Denmark)

    Ma, Lin; Xinmin, Jin; Kerekes, Tamas

    2009-01-01

    The Neutral Point Clamped topology due to high efficiency, low leakage current and EMI, its integration is widely used in the distributed generation (DG) systems. However the main disadvantage of the NPC inverter is given by an unequal distribution of the losses in the semiconductor devices, which...... leads to an unequal distribution of temperature. By using the Active NPC topology, the power losses distribution problem is alleviated. The modulation strategy is a key issue for losses distribution in this topology. In this paper two known strategies are discussed and a new proposed PWM strategy......, namely the Adjustable Losses Distribution (ALD) PWM strategy is proposed for better losses distribution in the Active NPC (ANPC) topology. Simulations using Simulink and the PLECS toolbox have been done for evaluating efficiency of different NPC topologies and some experimental results are presented...

  15. The contribution to distribution network fault levels from the connection of distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This report summarises the findings of a study investigating the potential impact of distributed generation (DG) on the UK distribution network fault levels up to the year 2010, and examining ways of managing the fault levels so that they do not become a barrier to increased penetration of DG. The project focuses on the circumstances and scenarios that give rise to the fault levels. The background to the study is traced, and a technical review is presented covering the relationship between DG and fault levels, and the likely impact in the period to 2010. Options for managing increased fault levels, and fault level management and costs are outlined, and a case study is given. The measurement and calculation of fault level values are described along with constraints to DG penetration due to fault level limitations, characteristics of DG machines, and long term perspectives to 2020-2030.

  16. A high-voltage equipment (high voltage supply, high voltage pulse generators, resonant charging inductance, synchro-instruments for gyrotron frequency measurements) for plasma applications

    International Nuclear Information System (INIS)

    Spassov, Velin

    1996-01-01

    This document reports my activities as visitor-professor at the Gyrotron Project - INPE Plasma Laboratory. The main objective of my activities was designing, construction and testing a suitable high-voltage pulse generator for plasma applications, and efforts were concentrated on the following points: Design of high-voltage resonant power supply with tunable output (0 - 50 kV) for line-type high voltage pulse generator; design of line-type pulse generator (4 microseconds pulse duration, 0 - 25 kV tunable voltage) for non linear loads such as a gyrotron and P III reactor; design of resonant charging inductance for resonant line-type pulse generator, and design of high resolution synchro instrument for gyrotron frequency measurement. (author)

  17. Quantification of wing and body kinematics in connection to torque generation during damselfly yaw turn

    Science.gov (United States)

    Zeyghami, Samane; Bode-Oke, Ayodeji T.; Dong, HaiBo

    2017-01-01

    This study provides accurate measurements of the wing and body kinematics of three different species of damselflies in free yaw turn flights. The yaw turn is characterized by a short acceleration phase which is immediately followed by an elongated deceleration phase. Most of the heading change takes place during the latter stage of the flight. Our observations showed that yaw turns are executed via drastic rather than subtle changes in the kinematics of all four wings. The motion of the inner and outer wings were found to be strongly linked through their orientation as well as their velocities with the inner wings moving faster than the outer wings. By controlling the pitch angle and wing velocity, a damselfly adjusts the angle of attack. The wing angle of attack exerted the strongest influence on the yaw torque, followed by the flapping and deviation velocities of the wings. Moreover, no evidence of active generation of counter torque was found in the flight data implying that deceleration and stopping of the maneuver is dominated by passive damping. The systematic analysis carried out on the free flight data advances our understanding of the mechanisms by which these insects achieve their observed maneuverability. In addition, the inspiration drawn from this study can be employed in the design of low frequency flapping wing micro air vehicles (MAV's).

  18. Connecting small ligands to generate large tubular metal-organic architectures

    International Nuclear Information System (INIS)

    Goforth, Andrea M.; Su, Cheng-Yong; Hipp, Rachael; Macquart, Rene B.; Smith, Mark D.; Loye, Hans-Conrad zur

    2005-01-01

    The new metal-organic framework materials, ZnF(Am 2 TAZ).solvents and ZnF(TAZ).solvents (Am 2 TAZ=3,5-diamino-1,2,4-triazole, TAZ=1,2,4-triazole), have been synthesized solvothermally and structurally characterized by either Rietveld refinement from powder XRD data or by single crystal X-ray diffraction. The three-dimensional structures of the compounds display open-ended, tubular channels, which are constituted of covalently bonded hexanuclear metallamacrocycles (Zn 6 F 6 (ligand) 6 ). The tubular channels are subsequently covalently joined into a honeycomb-like hexagonal array to generate the three-dimensional porous framework. In the case of ZnF(Am 2 TAZ).solvents, hydrophilic -NH 2 groups point into the channels, effectively reducing their inner diameter relative to ZnF(TAZ).solvents. The present compounds are isostructural to one another and to the previously reported ZnF(AmTAZ).solvents (AmTAZ=3-amino-1,2,4-triazole), illustrative of the fact that the internal size and chemical properties of the framework may be altered by modification of the small, heterocyclic ligand. In addition to demonstrating the ability to modify the basic framework, ZnF(TAZ).solvents and ZnF(Am 2 TAZ).solvents are two of the most thermally stable coordination frameworks known to date. - Graphical abstract: Top view of the open-ended, honeycomb tubular architecture of ZnF(Am 2 TAZ)

  19. Optimal Dispatch of Unreliable Electric Grid-Connected Diesel Generator-Battery Power Systems

    Science.gov (United States)

    Xu, D.; Kang, L.

    2015-06-01

    Diesel generator (DG)-battery power systems are often adopted by telecom operators, especially in semi-urban and rural areas of developing countries. Unreliable electric grids (UEG), which have frequent and lengthy outages, are peculiar to these regions. DG-UEG-battery power system is an important kind of hybrid power system. System dispatch is one of the key factors to hybrid power system integration. In this paper, the system dispatch of a DG-UEG-lead acid battery power system is studied with the UEG of relatively ample electricity in Central African Republic (CAR) and UEG of poor electricity in Congo Republic (CR). The mathematical models of the power system and the UEG are studied for completing the system operation simulation program. The net present cost (NPC) of the power system is the main evaluation index. The state of charge (SOC) set points and battery bank charging current are the optimization variables. For the UEG in CAR, the optimal dispatch solution is SOC start and stop points 0.4 and 0.5 that belong to the Micro-Cycling strategy and charging current 0.1 C. For the UEG in CR, the optimal dispatch solution is of 0.1 and 0.8 that belongs to the Cycle-Charging strategy and 0.1 C. Charging current 0.1 C is suitable for both grid scenarios compared to 0.2 C. It makes the dispatch strategy design easier in commercial practices that there are a few very good candidate dispatch solutions with system NPC values close to that of the optimal solution for both UEG scenarios in CAR and CR.

  20. Enhanced integrated converter. Combined cabled-connected and inductive charging of electric vehicles; Hoeher integrierter Stromrichter. Kombiniert kabelgebundenes und induktives Laden von Elektrofahrzeugen

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Marco; Barth, Heike; Braun, Martin [Fraunhofer Institut fuer Windenergie und Energiesystemtechnik (IWES), Kassel (Germany)

    2011-07-01

    The main goal of the German energy concept is the reduction of CO{sub 2}-emissions in which regenerative energy and electromobility play a pioneering role. Large emission reductions can be made through the use of electric vehicles charged with renewable energy, where the battery acts as mobile storage unit. Current charging systems only allow for cable based charging. New developments now permit vehicle battery charging via contactless, inductive methods. Using the same power electronics and inductors, a new, higher integrated inverter is capable of both single and three phase charging as well as inductive charging. (orig.)

  1. Flicker Mitigation of Grid Connected Wind Turbines Using STATCOM

    DEFF Research Database (Denmark)

    Sun, Tao; Chen, Zhe; Blaabjerg, Frede

    2004-01-01

    to the point of common coupling (PCC) to relieve the flicker produced by grid connected wind turbines and the corresponding control scheme is described in detail. Simulation results show that STATCOM is an effective measure to mitigate the flicker level during continuous operation of grid connected wind......Grid connected wind turbines may produce flicker during continuous operation. In this paper flicker emission of grid connected wind turbines with doubly fed induction generators is investigated during continuous operation. A STATCOM using PWM voltage source converter (VSC) is connected in shunt...

  2. Electricity generation and microbial community in response to short-term changes in stack connection of self-stacked submersible microbial fuel cell powered by glycerol

    DEFF Research Database (Denmark)

    Zhao, Nannan; Angelidaki, Irini; Zhang, Yifeng

    2017-01-01

    community. In this study, a self-stacked submersible microbial fuel cell (SSMFC) powered by glycerol was tested to elucidate this important issue. In series connection, the maximum voltage output reached to 1.15 V, while maximum current density was 5.73 mA in parallel. In both connections, the maximum power......Stack connection (i.e., in series or parallel) of microbial fuel cell (MFC) is an efficient way to boost the power output for practical application. However, there is little information available on short-term changes in stack connection and its effect on the electricity generation and microbial...... density increased with the initial glycerol concentration. However, the glycerol degradation was even faster in parallel connection. When the SSMFC was shifted from series to parallel connection, the reactor reached to a stable power output without any lag phase. Meanwhile, the anodic microbial community...

  3. Dynamic voltage stability of a distribution system with high penetration of grid-connected photovoltaic type solar generators

    Directory of Open Access Journals (Sweden)

    Zetty Adibah Kamaruzzaman

    2016-06-01

    Full Text Available This paper presents the impact of grid-connected photovoltaic (PV generator on dynamic voltage stability of a power distribution system by considering solar intermittency, PV penetration level, and contingencies such as line outage and load increase. The IEEE 13 node test feeder is used as a test system, and a solar PV of 0.48 kV/0.5 MVA is integrated into the test system. Test results show that system voltage is stable at high PV penetration levels. Increase in load causes voltage instability, in which voltage drops below its allowable operating limit. Thus, increase in PV penetration level does not improve system voltage stability because the system experiences voltage collapse during line outage.

  4. Dynamic imaging of coherent sources reveals different network connectivity underlying the generation and perpetuation of epileptic seizures.

    Directory of Open Access Journals (Sweden)

    Lydia Elshoff

    Full Text Available The concept of focal epilepsies includes a seizure origin in brain regions with hyper synchronous activity (epileptogenic zone and seizure onset zone and a complex epileptic network of different brain areas involved in the generation, propagation, and modulation of seizures. The purpose of this work was to study functional and effective connectivity between regions involved in networks of epileptic seizures. The beginning and middle part of focal seizures from ictal surface EEG data were analyzed using dynamic imaging of coherent sources (DICS, an inverse solution in the frequency domain which describes neuronal networks and coherences of oscillatory brain activities. The information flow (effective connectivity between coherent sources was investigated using the renormalized partial directed coherence (RPDC method. In 8/11 patients, the first and second source of epileptic activity as found by DICS were concordant with the operative resection site; these patients became seizure free after epilepsy surgery. In the remaining 3 patients, the results of DICS / RPDC calculations and the resection site were discordant; these patients had a poorer post-operative outcome. The first sources as found by DICS were located predominantly in cortical structures; subsequent sources included some subcortical structures: thalamus, Nucl. Subthalamicus and cerebellum. DICS seems to be a powerful tool to define the seizure onset zone and the epileptic networks involved. Seizure generation seems to be related to the propagation of epileptic activity from the primary source in the seizure onset zone, and maintenance of seizures is attributed to the perpetuation of epileptic activity between nodes in the epileptic network. Despite of these promising results, this proof of principle study needs further confirmation prior to the use of the described methods in the clinical praxis.

  5. Ultra-trace determination of iodine in sediments and biological material using UV photochemical generation-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, Patricia [Institute for National Measurements Standards, National Research Council Canada, Ottawa, Ontario, K1A 0R6 (Canada)], E-mail: patricia.grinberg@nrc.ca; Sturgeon, Ralph E. [Institute for National Measurements Standards, National Research Council Canada, Ottawa, Ontario, K1A 0R6 (Canada)

    2009-03-15

    Several sample preparation techniques have been evaluated for the determination of iodine using UV-photochemical generation-quadrupole inductively coupled plasma mass spectrometry. Thermal decomposition of samples at 1000 {sup o}C followed by capture of the liberated iodine in dilute acetic acid permitted subsequent UV-photochemical generation of a volatile iodine species that serves to enhance sensitivity 25-fold over conventional solution nebulization, delivering reagent blank detection limits of 8.75 pg g{sup -1127}I and 0.075 pg g{sup -1129}I for solid samples (400 mg test mass). The methodology was validated through determination of total iodine in several Standard Reference Materials, including NIST 1572 Citrus leaves, NIST 1549 Non-fat milk powder, NIST 1566a Oyster tissue and NIST 2709 San Joaquin Soil. Liberation of iodine from samples and its collection as well as photochemical generation were quantitative, permitting calibration to be achieved using standards prepared in dilute acetic acid.

  6. Mesoporous generation-inspired ultrahigh capacitive deionization performance by sono-assembled activated carbon/inter-connected graphene network architecture

    International Nuclear Information System (INIS)

    Song, Haiou; Wu, Yifan; Zhang, Shupeng; Li, Wentao; Wang, Baijun; Wang, Changming; Gao, Juanjuan; Li, Aimin

    2016-01-01

    Highlights: • 3D AC/inter-connected graphene network architecture has been constructed for CDI application. • Generated mesoporous structures can inspire ultrahigh capacitive deionization performance. • Usage of the smaller amounts (5 wt%) of functionalized graphene reduce the secondary pollution. • Inter-connected graphene network as the conductive bridge can decrease the aggregation of AC. • The environmental and economical composite electrode is suitable for practical CDI application. - Abstract: Capacitive deionization (CDI) is an emerging technology that supplies deionized water to resolve the fresh water shortage. CDI electrodes are mainly made up of carbon materials, of which the deionization performance is closely related to their physical properties and structures. Hence, a rational design of electrode material structure is essentially significant. Functionalized graphene (fG) in particular has recently been regarded as characteristic CDI electrode material. However, preparation of fG based on graphene oxide usually results in serious secondary pollution due to usage of highly poisonous chemicals, and thus still cannot meet the demand of practical application. It is feasible that environmentally-friendly activated carbon (AC) and small amounts of fGs can be combined rationally, and used as CDI electrodes. Here, sono-assembled AC/m-phenylenediamine (mPEA) or p-phenylenediaminefG inter-connected network architecture has been constructed for the first time successfully. The specific capacitances of the AC/fG composites were found to be significantly higher than that of the AC electrode owing to mesoporous generation. Also, among all the samples, the AC composite with 5 wt % mPEA-fG exhibited an ultrahigh electrosorption capacity of 12.58 mg/g (or 0.22 mmol/g) in NaCl solution. These observations indicate that fG can serve as an efficient conductive bridge to decrease the aggregation of AC particles, and improve the electron transfer with the

  7. Evaluation of the Trajectory Sensitivity Analysis of the DFIG Control Parameters in Response to Changes in Wind Speed and the Line Impedance Connection to the Grid DFIG

    Directory of Open Access Journals (Sweden)

    Mehdi Fooladgar

    2015-01-01

    Full Text Available Economic and environmental conditions often make large stations and transmission lines, restrictions are placed. Small and medium-sized production units connected to existing systems as a strategy is in progress. These units are usually near the center of the load placed and distributed generators (DG famous are the DG are allowed types vary, such as induction generators rack squirrel-connected wind turbines, generators fed induction double mounted wind turbines, fuel cells connected to the system by power electronic converters or synchronous generator connected to the turbine combustion [10]. This way sensitivity analysis in systems of distributed generation (DG is assessed. It is shown that the method can detect the effect of control parameters listed wind turbine connected to a double-fed induction generator (DFIG Badoou the impedance of the changing the speed of on the stability of the transmission line useful system invested. The control parameters of the importance of influencing the behavior of DFIG are divided.

  8. SYSTEM OPTIMIZATION FOR THE AUTOMATIC SIMULTANEOUS DETERMINATION OF ARSENIC, SELENIUM, AND ANTIMONY, USING HYDRIDE GENERATION INTRODUCTION TO AN INDUCTIVELY COUPLED PLASMA.

    Science.gov (United States)

    Pyen, Grace S.; Browner, Richard F.; Long, Stephen

    1986-01-01

    A fixed-size simplex has been used to determine the optimum conditions for the simultaneous determination of arsenic, selenium, and antimony by hydride generation and inductively coupled plasma emission spectrometry. The variables selected for the simplex were carrier gas flow rate, rf power, viewing height, and reagent conditions. The detection limit for selenium was comparable to the preoptimized case, but there were twofold and fourfold improvements in the detection limits for arsenic and antimony, respectively. Precision of the technique was assessed with the use of artificially prepared water samples.

  9. Real And Reactive Power Saving In Three Phase Induction Machine Using Star-Delta Switching Schemes

    Directory of Open Access Journals (Sweden)

    Ramesh Daravath

    2017-04-01

    Full Text Available Induction machines are the most commonly used industrial drives for variety of applications. It has been estimated that induction motors consumes approximately 50 of all the electric energy generated. Further in the area of renewable energy sources such as wind or bio-mass energy induction machines have been found suitable for functioning as generators. In this context it may be mentioned that a star-delta switching is common for the starting of three-phase induction motor. Now it is proposed to use this star-delta switching for energy conservation of induction machines i.e. at times of reduced loads the machine switched back to star connection. Using a three-phase 400 V 50 Hz 4-pole induction machine it has been demonstrated that the star-delta switching of stator winding of three-phase induction machine motor generator operations reconnected in star at suitable reduced loads with a switching arrangement can result in improved efficiency and power factor as compared to a fixed delta or star connection. The predetermined values along with the experimental results have also been presented in this report. A simulation program has been developed for the predetermination of performance of the three-phase induction machine using exact equivalent circuit. A case study on a 250 kW 400 V 4-pole three-phase induction machine operated with different load cycles reveals the significant real and reactive power savings that could be obtained in the present proposal.

  10. Integration of Hybrid PV/Wind Generation System Using Fuzzy MPPT in Grid Connected System for Remote Area

    Directory of Open Access Journals (Sweden)

    Soedibyo

    2016-01-01

    Full Text Available Photovoltaic and wind are renewable energy resources that widely used and grow rapidly in fulfilling electricity demand. Powers from both technologies depend on sunlight intensity and wind speed. For small scale power generation, DC voltage from both technologies is low and requires step-up converter to raise DC voltage ratio before converted into AC voltage. To optimize this system, step-up converter must have high ratio and efficiency to a distance of wide voltage input. This paper proposed an operation simulation and arrangement of DC-DC converter along with DC-AC from hybrid source PV-Wind which integrated to grid utilities without using storage device. High Gain Integrated Cascade Boost (HGICB is DC-DC converter that has quadratic voltage ratio and used in this research. Then DC link connected to Voltage Source Inverter (VSI which interconnected with utility grid and controlled by current control method. The total installed capacity of hybrid source is 4.4 kW. Wind turbine uses PMSG along with full bridge rectifier. To maximize and stabilize the generated power, MPPT fuzzy is used. Result from the simulation shows that converter capable to maintain maximum power whether from PV and wind turbine which canalized to utility grid in various irradiation condition, wind speed, and grid load alteration.

  11. Generation and acceleration of high-current annular electron beam in linear induction accelerator and generation of the power microwave radiation from Cherenkov TWT

    International Nuclear Information System (INIS)

    Abubakirov, E.V.; Arkhipov, O.V.; Bobyleva, L.V.

    1990-01-01

    The section of linear induction accelerator (LIA) with a strong guiding magnetic field (up to 1.5 T), with output beam power up to 2 GW and beam pulse duration 60 ns is created and investigated by experiment. The beam energy gain is equal to 10 keV/sm with explosive emission is used; the large length of the beam propagation (1.5 m) without spolling of the beam with high beam energy gain has been established. The microwave radiation power about 30-100 MW has achieved from relativistic Cherenkov travelling wave tube with high exponential gain on the basis of LIA and high-current diode

  12. The utilization of induction generators working with PATs (pumps working as turbines) in electric energy generation; A utilizacao de geradores de inducao acionados por BFTs (bombas funcionando como turbinas) na geracao de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Viana, Augusto Nelson Carvalho; Rezek, Angelo Jose Junqueira; Medeiros, Daniel de Macedo [Universidade Federal de Itajuba (UNIFEI), MG (Brazil). Programa de Pos-graduacao em Engenharia da Energia], e-mail: augusto@unifei.edu.br, e-mail: rezek@iee.efei.br, e-mail: macedo@unifei.edu.br

    2004-07-01

    The utilization of the Pumps working as Turbines (PATs) in micro hydro-energy resources to replace the conventional turbines as Pelton, Francis and Propeller have been used in countries as USA, Germany and France. In the mean time, in Brazil this practice and the utilization of induction generators working with PATs is still in the scope of the laboratory experiments. This work, based on experimental results carried on in Laboratory of Hydromechanics for Small Hydro Power Plants (Laboratorio Hidromecanico para Pequenas Centrais Hidroeletricas - LHPCH - UNIFEI), (VIANA, 1987), (VIANA e NOGUEIRA, 1990), propose the utilization of asynchronous generator groups operating with PATs. To show the investment cost decrease in micro hydro power plants (MHPs), is showed the Boa Esperanca MPH example, in which is presented a comparison between the synchronous generator group cost working with a Michell-Banki turbine and a asynchronous generator group operating with a PAT. (author)

  13. Linear induction accelerator

    Science.gov (United States)

    Buttram, M.T.; Ginn, J.W.

    1988-06-21

    A linear induction accelerator includes a plurality of adder cavities arranged in a series and provided in a structure which is evacuated so that a vacuum inductance is provided between each adder cavity and the structure. An energy storage system for the adder cavities includes a pulsed current source and a respective plurality of bipolar converting networks connected thereto. The bipolar high-voltage, high-repetition-rate square pulse train sets and resets the cavities. 4 figs.

  14. Generation connected with images

    Directory of Open Access Journals (Sweden)

    Adriana RECAMÁN PAYO

    2011-12-01

    Full Text Available 0 0 1 197 1086 Instituto Universitario de Ciencias de la Educación 9 2 1281 14.0 Normal 0 21 false false false ES JA X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabla normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin-top:0cm; mso-para-margin-right:0cm; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0cm; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:Calibri; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-ansi-language:ES; mso-fareast-language:EN-US;} In learning contexts studying the image as a focus of sensitive knowledge and formative purposes is crucial to achieve high levels of quality and educational excellence. As Renobell (2005 stated, image analysis encourages the development of critical capacity and contributes to developing a personal style for the gradual acquisition of a visual culture. Images educate and consequently, their presence in the field of education should not be a mere accompaniment to the text. They should not be limited to adorn or illustrate a linguistic content but to complement and deepen it, activating the thought and the reflection of the reader. In Internet culture, image as a focus of knowledge, of shared use, of social content and educational purposes, contribute to explain the implications and vivacity around this technological environment, which plays a leading role in the current social changes and movements. The culture of the network has changed our perceptual sensitivity to interpret images, which are now more complex, integrated, multidimensional and dynamic than ever. The interactivity, the strong relationship with the text content, the graphic sequentiality, the associated sound effects or the iconical text design reveal the importance of image in the net culture.

  15. ANALYSIS OF MONTE CARLO SIMULATION SAMPLING TECHNIQUES ON SMALL SIGNAL STABILITY OF WIND GENERATOR- CONNECTED POWER SYSTEM

    Directory of Open Access Journals (Sweden)

    TEMITOPE RAPHAEL AYODELE

    2016-04-01

    Full Text Available Monte Carlo simulation using Simple Random Sampling (SRS technique is popularly known for its ability to handle complex uncertainty problems. However, to produce a reasonable result, it requires huge sample size. This makes it to be computationally expensive, time consuming and unfit for online power system applications. In this article, the performance of Latin Hypercube Sampling (LHS technique is explored and compared with SRS in term of accuracy, robustness and speed for small signal stability application in a wind generator-connected power system. The analysis is performed using probabilistic techniques via eigenvalue analysis on two standard networks (Single Machine Infinite Bus and IEEE 16–machine 68 bus test system. The accuracy of the two sampling techniques is determined by comparing their different sample sizes with the IDEAL (conventional. The robustness is determined based on a significant variance reduction when the experiment is repeated 100 times with different sample sizes using the two sampling techniques in turn. Some of the results show that sample sizes generated from LHS for small signal stability application produces the same result as that of the IDEAL values starting from 100 sample size. This shows that about 100 sample size of random variable generated using LHS method is good enough to produce reasonable results for practical purpose in small signal stability application. It is also revealed that LHS has the least variance when the experiment is repeated 100 times compared to SRS techniques. This signifies the robustness of LHS over that of SRS techniques. 100 sample size of LHS produces the same result as that of the conventional method consisting of 50000 sample size. The reduced sample size required by LHS gives it computational speed advantage (about six times over the conventional method.

  16. Development of coupling systems at the hybrid frequency for the non-inductive current generation inside a tokamak; Developpement de coupleurs a la frequence hybride pour la generation non inductive du courant dans un tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Berio, S. [Association Euratom-CEA, Centre d`Etudes Nucleaires de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee]|[Aix-Marseille-1 Univ., 13 - Marseille (France)

    1996-12-31

    Used at its first time as an heating method in order to reach the temperature requisite for the fusion of a thermonuclear plasma, the hybrid waves has shown that they were the more efficient method for non-inductive current drive in a tokamak. The size and the objectives of a next machine such as ITER lead to the design of new antennae (in process of realisation on Tore Supra) made of oversized waveguides. This new concept of antenna will be more simple, more robust and will be able to transmit the same if not much power than the present antennae. This thesis contribute to the development of a new code called ALOHA (for `Advanced LOwer Hybrid Antenna`) which, at the end, will be able to give the characteristics and the behaviours of this new oversized antennae in front of a tokamak plasma. This thesis is also a first step in the interpretation of some experimental data concerning the measurement of coupling, absorption and current drive of the actual hybrid wave launched by a grill with rectangular waveguides. Moreover, this thesis lay some foundations of the study of these new antennae in front of a on-parallel confinement magnetic field and/or in front of poloidal inhomogeneities of plasma. (authors) 53 refs.

  17. Calculation of temperature fields formed in induction annealing of closing welded joint of jacket of steam generator for WWER 440 type nuclear power plant using ICL 2960 computer

    International Nuclear Information System (INIS)

    Sajnar, P.; Fiala, J.

    1983-01-01

    The problems are discussed of the mathematical description and simulation of temperature fields in annealing the closing weld of the steam generator jacket of the WWER 440 nuclear power plant. The basic principles are given of induction annealing, the method of calculating temperature fields is indicated and the mathematical description is given of boundary conditions on the outer and inner surfaces of the steam generator jacket for the computation of temperature fields arising during annealing. Also described are the methods of determining the temperature of exposed parts of heat exchange tubes inside the steam generator and the technical possibilities are assessed of the annealing equipment from the point of view of its computer simulation. Five alternatives are given for the computation of temperature fields in the area around the weld for different boundary conditions. The values are given of maximum differences in the temperatures of the metal in the annealed part of the steam generator jacket which allow the assessment of individual computation variants, this mainly from the point of view of observing the course of annealing temperature in the required width of the annealed jacket of the steam generator along both sides of the closing weld. (B.S.)

  18. A new nebulization device with exchangeable aerosol generation mode as a useful tool to investigate sample introduction processes in inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Grotti, Marco; Lagomarsino, Cristina; Frache, Roberto

    2004-01-01

    A new sample introduction device has been designed in order to differentiate between the effects of the aerosol production and its following desolvation on analytical performances of an inductively coupled plasma optical spectrometer. This research tool allows to easily switch between the pneumatic and ultrasonic aerosol generation mode and to use a joint desolvation chamber. In this way, a real comparison between aerosol production systems may be attained and the influence of aerosol generation process on analytical figures clearly distinguished from that of the desolvation process. In this work, the separate effects of the aerosol generation and desolvation processes on analytical sensitivity and tolerance towards matrix effects have been investigated. Concerning sensitivity, it was found that both the processes play an important role in determining emission intensities, being the increase in sensitivity due to desolvation higher than that due to the improved aerosol generation efficiency. Concerning the matrix effects, a predominant role of the desolvation system was found, while the influence of the aerosol generation mode was much less important. For nitric acid, the decreasing effect was mitigated by the presence of a desolvation system, due to partial removal of the acid. On the contrary, the depressive effect of sulfuric acid was enhanced by the presence of a desolvation system, due to degradation of the solvent removal efficiency and to further decrease in the analyte transport rate caused by clustering phenomena. Concerning the interferences due to sodium and calcium, a depressive effect was observed, which is enhanced by desolvation

  19. Analysis and Implementation of Parallel Connected Two-Induction Motor Single-Inverter Drive by Direct Vector Control for Industrial Application

    DEFF Research Database (Denmark)

    Gunabalan, Ramachandiran; Padmanaban, Sanjeevikumar; Blaabjerg, Frede

    2015-01-01

    Sensorless-based direct vector control techniques are widely used for three-phase induction motor drive, whereas in case of multiple-motor control, it becomes intensively complicated and very few research articles in support to industrial applications were found. A straight-forward direct vector...... to estimate the rotor speed, rotor flux, and load torque of both motors. Simulation results along with theoretical background provided in this paper confirm the feasibility of operation of the ac motors and proves reliability for industrial applications....

  20. Huge Inverse Magnetization Generated by Faraday Induction in Nano-Sized Au@Ni Core@Shell Nanoparticles.

    Science.gov (United States)

    Kuo, Chen-Chen; Li, Chi-Yen; Lee, Chi-Hung; Li, Hsiao-Chi; Li, Wen-Hsien

    2015-08-25

    We report on the design and observation of huge inverse magnetizations pointing in the direction opposite to the applied magnetic field, induced in nano-sized amorphous Ni shells deposited on crystalline Au nanoparticles by turning the applied magnetic field off. The magnitude of the induced inverse magnetization is very sensitive to the field reduction rate as well as to the thermal and field processes before turning the magnetic field off, and can be as high as 54% of the magnetization prior to cutting off the applied magnetic field. Memory effect of the induced inverse magnetization is clearly revealed in the relaxation measurements. The relaxation of the inverse magnetization can be described by an exponential decay profile, with a critical exponent that can be effectively tuned by the wait time right after reaching the designated temperature and before the applied magnetic field is turned off. The key to these effects is to have the induced eddy current running beneath the amorphous Ni shells through Faraday induction.

  1. Huge Inverse Magnetization Generated by Faraday Induction in Nano-Sized Au@Ni Core@Shell Nanoparticles

    Directory of Open Access Journals (Sweden)

    Chen-Chen Kuo

    2015-08-01

    Full Text Available We report on the design and observation of huge inverse magnetizations pointing in the direction opposite to the applied magnetic field, induced in nano-sized amorphous Ni shells deposited on crystalline Au nanoparticles by turning the applied magnetic field off. The magnitude of the induced inverse magnetization is very sensitive to the field reduction rate as well as to the thermal and field processes before turning the magnetic field off, and can be as high as 54% of the magnetization prior to cutting off the applied magnetic field. Memory effect of the induced inverse magnetization is clearly revealed in the relaxation measurements. The relaxation of the inverse magnetization can be described by an exponential decay profile, with a critical exponent that can be effectively tuned by the wait time right after reaching the designated temperature and before the applied magnetic field is turned off. The key to these effects is to have the induced eddy current running beneath the amorphous Ni shells through Faraday induction.

  2. Huge Inverse Magnetization Generated by Faraday Induction in Nano-Sized Au@Ni Core@Shell Nanoparticles

    Science.gov (United States)

    Kuo, Chen-Chen; Li, Chi-Yen; Lee, Chi-Hung; Li, Hsiao-Chi; Li, Wen-Hsien

    2015-01-01

    We report on the design and observation of huge inverse magnetizations pointing in the direction opposite to the applied magnetic field, induced in nano-sized amorphous Ni shells deposited on crystalline Au nanoparticles by turning the applied magnetic field off. The magnitude of the induced inverse magnetization is very sensitive to the field reduction rate as well as to the thermal and field processes before turning the magnetic field off, and can be as high as 54% of the magnetization prior to cutting off the applied magnetic field. Memory effect of the induced inverse magnetization is clearly revealed in the relaxation measurements. The relaxation of the inverse magnetization can be described by an exponential decay profile, with a critical exponent that can be effectively tuned by the wait time right after reaching the designated temperature and before the applied magnetic field is turned off. The key to these effects is to have the induced eddy current running beneath the amorphous Ni shells through Faraday induction. PMID:26307983

  3. Faroe Islands Wind-Powered Space Heating Microgrid Using Self-Excited 220 kW Induction Generator

    DEFF Research Database (Denmark)

    Thomsen, Bjarti; Guerrero, Josep M.; Thogersen, Paul

    2014-01-01

    its own control of frequency and voltage. A micro-controller is used to control frequency by matching load (heaters) to generated power and to produce the correct reactive power and voltage by switched capacitors. One challenge is the startup procedure at high winds speeds when nominal speed tend...

  4. Induction of Programmed Cell Death by Parvovirus H-1 in U937 Cells: Connection with the Tumor Necrosis Factor Alpha Signalling Pathway

    Science.gov (United States)

    Rayet, Béatrice; Lopez-Guerrero, José-Antonio; Rommelaere, Jean; Dinsart, Christiane

    1998-01-01

    The human promonocytic cell line U937 undergoes apoptosis upon treatment with tumor necrosis factor alpha (TNF-α). This cell line has previously been shown to be very sensitive to the lytic effect of the autonomous parvovirus H-1. Parvovirus infection leads to the activation of the CPP32 ICE-like cysteine protease which cleaves the enzyme poly(ADP-ribose)polymerase and induces morphologic changes that are characteristic of apoptosis in a way that is similar to TNF-α treatment. This effect is also observed when the U937 cells are infected with a recombinant H-1 virus which expresses the nonstructural (NS) proteins but in which the capsid genes are replaced by a reporter gene, indicating that the induction of apoptosis can be assigned to the cytotoxic nonstructural proteins in this cell system. The c-Myc protein, which is overexpressed in U937 cells, is rapidly downregulated during infection, in keeping with a possible role of this product in mediating the apoptotic cell death induced by H-1 virus infection. Interestingly, four clones (designated RU) derived from the U937 cell line and selected for their resistance to H-1 virus (J. A. Lopez-Guerrero et al., Blood 89:1642–1653, 1997) failed to decrease c-Myc expression upon treatment with differentiation agents and also resisted the induction of cell death after TNF-α treatment. Our data suggest that the RU clones have developed defense strategies against apoptosis, either by their failure to downregulate c-Myc and/or by activating antiapoptotic factors. PMID:9765434

  5. Determination of mercury in coal by isotope dilution cold-vapor generation inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Long, S.E.; Kelly, W.R.

    2002-04-01

    A method based on isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICPMS) has been developed for high-accuracy determinations of mercury in bituminous and sub-bituminous coals. A closed-system digestion process employing a Carius tube is used to completely oxidize the coal matrix and chemically equilibrate the mercury in the sample with a Hg-201 isotopic spike. The digestates are diluted with high-purity quartz-distilled water, and the mercury is released as a vapor by reduction with tin chloride. Measurements of Hg-201/Hg-202 isotope ratios are made using a quadrupole ICPMS system in time-resolved analysis mode. The new method has some significant advantages over existing methods. The instrument detection limit is less than 1 pg/mL. The average blank (n = 17) is 30 pg, which is roughly 1 order of magnitude lower than the equivalent microwave digestion procedure. The detection limit in coal is blank limited and is similar to 40 pg/g. Memory effects are very low. The relative reproducibility of the analytical measurements is similar to 0.5% for mercury concentrations in the range 10-150 ng/g. The method has been used to measure mercury concentrations in six coal reference materials, SRM 1632b (77.4 ng/g), SRM 1632c (94.3 ng/g), BCR 40 (433.2 ng/g), BCR 180 (125.0 ng/g), BCR 181 (135.8 ng/g), and SARM 20 (252.6 ng/g), as well as a coal fly ash, SRM 1633b (143.1 ng/g). The method is equally applicable to other types of fossil fuels including both crude and refined oils.

  6. Labor Induction

    Science.gov (United States)

    f AQ FREQUENTLY ASKED QUESTIONS FAQ154 LABOR, DELIVERY, AND POSTPARTUM CARE Labor Induction • What is labor induction? • Why is labor induced? • What is the Bishop score? • What is “ripening ...

  7. Global model analysis of negative ion generation in low-pressure inductively coupled hydrogen plasmas with bi-Maxwellian electron energy distributions

    International Nuclear Information System (INIS)

    Huh, Sung-Ryul; Kim, Nam-Kyun; Jung, Bong-Ki; Chung, Kyoung-Jae; Hwang, Yong-Seok; Kim, Gon-Ho

    2015-01-01

    A global model was developed to investigate the densities of negative ions and the other species in a low-pressure inductively coupled hydrogen plasma with a bi-Maxwellian electron energy distribution. Compared to a Maxwellian plasma, bi-Maxwellian plasmas have higher populations of low-energy electrons and highly vibrationally excited hydrogen molecules that are generated efficiently by high-energy electrons. This leads to a higher reaction rate of the dissociative electron attachment responsible for negative ion production. The model indicated that the bi-Maxwellian electron energy distribution at low pressures is favorable for the creation of negative ions. In addition, the electron temperature, electron density, and negative ion density calculated using the model were compared with the experimental data. In the low-pressure regime, the model results of the bi-Maxwellian electron energy distributions agreed well quantitatively with the experimental measurements, unlike those of the assumed Maxwellian electron energy distributions that had discrepancies

  8. Induction of peroxide and superoxide protective enzymes and physiological cross-protection against peroxide killing by a superoxide generator in Vibrio harveyi.

    Science.gov (United States)

    Vattanaviboon, Paiboon; Panmanee, Warunya; Mongkolsuk, Skorn

    2003-04-11

    Vibrio harveyi is a causative agent of destructive luminous vibriosis in farmed black tiger prawn (Penaeus monodon). V. harveyi peroxide and superoxide stress responses toward elevated levels of a superoxide generated by menadione were investigated. Exposure of V. harveyi to sub-lethal concentrations of menadione induced high expression of genes in both the OxyR regulon (e.g., a monofunctional catalase or KatA and an alkyl hydroperoxide reductase subunit C or AhpC), and the SoxRS regulon (e.g., a superoxide dismutase (SOD) and a glucose-6-phosphate dehydrogenase). V. harveyi expressed two detectable, differentially regulated SOD isozymes, [Mn]-SOD and [Fe]-SOD. [Fe]-SOD was expressed constitutively throughout the growth phase while [Mn]-SOD was expressed at the stationary phase and could be induced by a superoxide generator. Physiologically, pre-treatment of V. harveyi with menadione induced cross-protection against subsequent exposure to killing concentrations of H(2)O(2). This induced cross-protection required newly synthesized proteins. However, the treatment did not induce significant protection against exposures to killing concentrations of menadione itself or cross-protect against an organic hydroperoxide (tert-butyl hydroperoxide). Unexpectedly, growing V. harveyi in high-salinity media induced protection against menadione killing. This protection was independent of SOD induction. Stationary-phase cells were more resistant to menadione killing than exponential-phase cells. The induction of oxidative stress protective enzymes and stress-altered physiological responses could play a role in the survival of this bacterium in the host marine crustaceans.

  9. Modeling, control and fault diagnosis of an isolated wind energy conversion system with a self-excited induction generator subject to electrical faults

    International Nuclear Information System (INIS)

    Attoui, Issam; Omeiri, Amar

    2014-01-01

    Highlights: • A new model of the SEIG is developed to simulate both the rotor and stator faults. • This model takes iron loss, main flux and cross flux saturation into account. • A new control strategy based on Fractional-Order Controller (FOC) is proposed. • The control strategy is developed for the control of the wind turbine speed. • An on-line diagnostic procedure based on the stator currents analysis is presented. - Abstract: In this paper, a contribution to modeling and fault diagnosis of rotor and stator faults of a Self-Excited Induction Generator (SEIG) in an Isolated Wind Energy Conversion System (IWECS) is proposed. In order to control the speed of the wind turbine, while basing on the linear model of wind turbine system about a specified operating point, a new Fractional-Order Controller (FOC) with a simple and practical design method is proposed. The FOC ensures the stability of the nonlinear system in both healthy and faulty conditions. Furthermore, in order to detect the stator and rotor faults in the squirrel-cage self-excited induction generator, an on-line fault diagnostic technique based on the spectral analysis of stator currents of the squirrel-cage SEIG by a Fast Fourier Transform (FFT) algorithm is used. Additionally, a generalized model of the squirrel-cage SEIG is developed to simulate both the rotor and stator faults taking iron loss, main flux and cross flux saturation into account. The efficiencies of generalized model, control strategy and diagnostic procedure are illustrated with simulation results

  10. Fuzzy logic based power management strategy of a multi-MW doubly-fed induction generator wind turbine with battery and ultracapacitor

    International Nuclear Information System (INIS)

    Sarrias-Mena, Raúl; Fernández-Ramírez, Luis M.; García-Vázquez, Carlos Andrés; Jurado, Francisco

    2014-01-01

    Integrating energy storage systems (ESS) with wind turbines results to be an interesting option for improving the grid integration capability of wind energy. This paper presents and evaluates a wind hybrid system consisting of a 1.5 MW doubly-fed induction generator (DFIG) wind turbine and double battery-ultracapacitor ESS. Commercially available components are used in this wind hybrid system. A novel supervisory control system (SCS) is designed and implemented, which is responsible for setting the active and reactive power references for each component of the hybrid system. A fuzzy logic controller, taking into account the grid demand, power generation prediction, actual DFIG power generation and state-of-charge (SOC) of the ESSs, sets the active power references. The reactive power references are proportionally delivered to each element regarding their current limitations in the SCS. The appropriate control of the power converters allows each power source to achieve the operation defined by the SCS. The wind hybrid system and SCS are assessed by simulation under wind fluctuations, grid demand changes, and grid disturbances. Results show an improved performance in the overall response of the system with the implementation of the SCS. - Highlights: • We study a wind hybrid system based on DFIG wind turbine, battery and ultracapacitor. • A novel supervisory control system based on fuzzy logic is designed and implemented. • The control improves the system response under different operating conditions

  11. Direct Flux Control for Stand-Alone Operation Brushless Doubly Fed Induction Generators Using a Resonant-Based Sliding-Mode Control Approach

    Directory of Open Access Journals (Sweden)

    Kai Ji

    2018-04-01

    Full Text Available In this paper, a novel voltage control strategy for stand-alone operation brushless doubly fed induction generators for variable speed constant frequency wind energy conversion systems was presented and discussed. Based on the model of the power generation system, the proposed direct flux control strategy employs a nonlinear reduced-order generalized integrator-based resonant sliding-mode control approach to directly calculate and regulate the output value of converter which the control winding stator requires so as to eliminate its instantaneous errors, without involving any synchronous rotating coordinate transformations. The stability, robustness and convergence capability of the proposed control strategy were described and analyzed. Owing to the fact no additional current control inner loops are involved, the system configuration is therefore simplified and the dynamic performance enhanced. A constant converter switching frequency was achieved by using space vector pulse width modulation, which reduces the harmonics of the generator terminal voltage. In addition, the feasibility and validity of the proposed scheme is verified by experiments, and excellent steady and transient performance is achieved.

  12. Induction linacs

    International Nuclear Information System (INIS)

    Keefe, D.

    1986-07-01

    The principle of linear induction acceleration is described, and examples are given of practical configurations for induction linacs. These examples include the Advanced Technology Accelerator, Long Pulse Induction Linac, Radial Line Accelerator (RADLAC), and Magnetically-Insulated Electron-Focussed Ion Linac. A related concept, the auto accelerator, is described in which the high-current electron-beam technology in the sub-10 MeV region is exploited to produce electron beams at energies perhaps as high as the 100 to 1000 MeV range. Induction linacs for ions are also discussed. The efficiency of induction linear acceleration is analyzed

  13. Determination of lead by hydride generation inductively coupled plasma mass spectrometry (HG-ICP-MS): On-line generation of plumbane using potassium hexacyanomanganate(III)

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, Vedat [Jackson State University, Department of Chemistry and Biochemistry, Jackson, MS 39217 (United States); Erciyes University, Faculty of Pharmacy, Department of Analytical Chemistry, 38039 Kayseri (Turkey); Arslan, Zikri, E-mail: zikri.arslan@jsums.edu [Jackson State University, Department of Chemistry and Biochemistry, Jackson, MS 39217 (United States); Rose, LaKeysha [Jackson State University, Department of Chemistry and Biochemistry, Jackson, MS 39217 (United States)

    2013-01-25

    Highlights: Black-Right-Pointing-Pointer Potassium hexacyanomanganate(III), (K{sub 3}Mn(CN){sub 6}, was utilized first time for hydride generation (HG). Black-Right-Pointing-Pointer Hexacyanomanganate(III) promoted generation of lead hydride (PbH{sub 4}) remarkably. Black-Right-Pointing-Pointer The HG method using K{sub 3}Mn(CN){sub 6} enhanced sensitivity by at least 40-fold. Black-Right-Pointing-Pointer The method detection limits for Pb were as low as 8 ng L{sup -1} by ICP-MS. Black-Right-Pointing-Pointer The method is highly suitable for quantitative determination of Pb in various samples and salt matrices by ICP-MS. - Abstract: A hydride generation (HG) procedure has been described for determination of Pb by ICP-MS using potassium hexacyanomanganate(III), K{sub 3}Mn(CN){sub 6}, as an additive to facilitate the generation of plumbane (PbH{sub 4}). Potassium hexacyanomanganate(III) was prepared in acidic medium as it was unstable in water. The stability of hexacyanomanganate(III) was examined in dilute solutions of HCl, HNO{sub 3} and H{sub 2}SO{sub 4}. The solutions prepared in 1% v/v H{sub 2}SO{sub 4} were found to be stable for over a period of 24 h. The least suitable medium was 1% v/v HNO{sub 3}. For generation of plumbane, acidic hexacyanomanganate(III) and sample solutions were mixed on-line along a 5-cm long tygon tubing (1.14 mm i.d.) and then reacted with 2% m/v sodium borohydride (NaBH{sub 4}). A concentration of 0.5% m/v K{sub 3}Mn(CN){sub 6} facilitated the generation of PbH{sub 4} remarkably. In comparison to H{sub 2}SO{sub 4}, HCl provided broader working range for which optimum concentration was 1% v/v. No significant interferences were noted from transition metals and hydride forming elements, up to 0.5 {mu}g mL{sup -1} levels, except Cu which depressed the signals severely. The depressive effects in the presence of 0.1 {mu}g mL{sup -1} Cu were alleviated by increasing the concentration of K{sub 3}Mn(CN){sub 6} to 2% m/v. Under these conditions

  14. Induction of apoptosis and antiproliferative activity of naringenin in human epidermoid carcinoma cell through ROS generation and cell cycle arrest.

    Directory of Open Access Journals (Sweden)

    Md Sultan Ahamad

    Full Text Available A natural predominant flavanone naringenin, especially abundant in citrus fruits, has a wide range of pharmacological activities. The search for antiproliferative agents that reduce skin carcinoma is a task of great importance. The objective of this study was to analyze the anti-proliferative and apoptotic mechanism of naringenin using MTT assay, DNA fragmentation, nuclear condensation, change in mitochondrial membrane potential, cell cycle kinetics and caspase-3 as biomarkers and to investigate the ability to induce reactive oxygen species (ROS initiating apoptotic cascade in human epidermoid carcinoma A431 cells. Results showed that naringenin exposure significantly reduced the cell viability of A431 cells (p<0.01 with a concomitant increase in nuclear condensation and DNA fragmentation in a dose dependent manner. The intracellular ROS generation assay showed statistically significant (p<0.001 dose-related increment in ROS production for naringenin. It also caused naringenin-mediated epidermoid carcinoma apoptosis by inducing mitochondrial depolarization. Cell cycle study showed that naringenin induced cell cycle arrest in G0/G1 phase of cell cycle and caspase-3 analysis revealed a dose dependent increment in caspase-3 activity which led to cell apoptosis. This study confirms the efficacy of naringenin that lead to cell death in epidermoid carcinoma cells via inducing ROS generation, mitochondrial depolarization, nuclear condensation, DNA fragmentation, cell cycle arrest in G0/G1 phase and caspase-3 activation.

  15. Half Bridge Inductive Heater

    Directory of Open Access Journals (Sweden)

    Zoltán GERMÁN-SALLÓ

    2015-12-01

    Full Text Available Induction heating performs contactless, efficient and fast heating of conductive materials, therefore became one of the preferred heating procedure in industrial, domestic and medical applications. During induction heating the high-frequency alternating currents that heat the material are induced by means of electromagnetic induction. The material to be heated is placed inside the time-varying magnetic field generated by applying a highfrequency alternating current to an induction coil. The alternating electromagnetic field induces eddy currents in the workpiece, resulting resistive losses, which then heat the material. This paper describes the design of a power electronic converter circuit for induction heating equipment and presents the obtained results. The realized circuit is a low power half bridge resonant inverter which uses power MOS transistors and adequate driver circuits.

  16. Inductive energy storage commutator

    International Nuclear Information System (INIS)

    Gavrilov, I.M.

    1987-01-01

    An inductive energy storage commutator is described. The value of commutated current is up to 800 A, the voltage amplitude in the load is up to 50 kV, the working frequency is equal to 1-50 Hz, the commutated power is up to 40 MW. The commutating device comprises of the first stage commutator having two in-series connected modules of the BTSV - 800/235 high-voltage thyristor unit, the second stage commutator containing three GMI-43A parallel connected powerful pulsed triodes, a commutating capacitor, an induction coil, two supplementary high-voltage thyristor keys (20 in-series connected thyristors T2-300 (13 class)), load, control pulse shapers, thyristor keys, power supply

  17. UVA Photoirradiation of Oxygenated Benz[a]anthracene and 3-Methylcholanthene - Generation of Singlet Oxygen and Induction of Lipid Peroxidation

    Directory of Open Access Journals (Sweden)

    Diógenes Herreño Sáenz

    2008-03-01

    Full Text Available Polycyclic aromatic hydrocarbons (PAHs are widespread genotoxic environmental pollutants and potentially pose a health risk to humans. Although the biological and toxicological activities, including metabolism, mutagenicity, and carcinogenicity, of PAHs have been thoroughly studied, their phototoxicity and photo-induced biological activity have not been well examined. We have long been interested in phototoxicity of PAHs and their derivatives induced by irradiation with UV light. In this paper we report the photoirradiation of a series of oxygenated benz[a]anthracene (BA and 3-methylcholanthene (3-MC by UVA light in the presence of a lipid, methyl linoleate. The studied PAHs include 2-hydroxy-BA (2-OH-BA, 3-hydroxy-BA (3-OH-BA, 5-hydroxymethyl-BA (5-CH2OH-BA, 7-hydroxymethyl-BA (7-CH2OH-BA, 12-hydroxymethyl-BA (12-CH2OH-BA, 7-hydroxymethyl-12-methyl-BA (7-CH2OH-12-MBA, 5-formyl-BA (5-CHO-BA, BA 5,6-cis-dihydrodiol (BA 5,6-cis-diol, 1-hydroxy-3- methylcholanthene (1-OH-3-MC, 1-keto-3-methylcholanthene (1-keto-3-MC, and 3-MC 1,2-diol. The results indicate that upon photoirradiation by UVA at 7 and 21 J/cm2, respectively all these compounds induced lipid peroxidation and exhibited a relationship between the dose of the light and the level of lipid peroxidation induced. To determine whether or not photoirradiation of these compounds by UVA light produces ROS, an ESR spin-trap technique was employed to provide direct evidence. Photoirradiation of 3-keto-3-MC by UVA (at 389 nm in the presence of 2,2,6,6-tetramethylpiperidine (TEMP, a specific probe for singlet oxygen, resulted in the formation of TEMPO, indicating that singlet oxygen was generated. These overall results suggest that UVA photoirradiation of oxygenated BA and 3-methylcholanthrene generates singlet oxygen, one of the reactive oxygen species (ROS, which induce lipid peroxidation.

  18. Inductive reasoning.

    Science.gov (United States)

    Hayes, Brett K; Heit, Evan; Swendsen, Haruka

    2010-03-01

    Inductive reasoning entails using existing knowledge or observations to make predictions about novel cases. We review recent findings in research on category-based induction as well as theoretical models of these results, including similarity-based models, connectionist networks, an account based on relevance theory, Bayesian models, and other mathematical models. A number of touchstone empirical phenomena that involve taxonomic similarity are described. We also examine phenomena involving more complex background knowledge about premises and conclusions of inductive arguments and the properties referenced. Earlier models are shown to give a good account of similarity-based phenomena but not knowledge-based phenomena. Recent models that aim to account for both similarity-based and knowledge-based phenomena are reviewed and evaluated. Among the most important new directions in induction research are a focus on induction with uncertain premise categories, the modeling of the relationship between inductive and deductive reasoning, and examination of the neural substrates of induction. A common theme in both the well-established and emerging lines of induction research is the need to develop well-articulated and empirically testable formal models of induction. Copyright © 2010 John Wiley & Sons, Ltd. For further resources related to this article, please visit the WIREs website. Copyright © 2010 John Wiley & Sons, Ltd.

  19. Contribution to the control of doubly-fed induction generators in wind power plants with particular consideration of asymmetrical grid conditions

    Energy Technology Data Exchange (ETDEWEB)

    Richter, Marlies

    2012-06-21

    In the study presented here, four different control strategies for the control of the inverter currents of a doubly-fed induction generator (DFIG) system are analysed and evaluated by means of simulation using Matlab/Simulink registered. Special attention is paid to the behaviour of the generator during asymmetrical grid voltage dips. Different control schemes are employed to reduce torque and DC-link voltage oscillations and the resulting additional loads on the system during such dips. The field-oriented control (FOC) scheme is the one usually deployed for the control of DFIGs in wind power plants and is used as the reference system within this study. The inverter currents (of the rotor-side inverter and the grid-side inverter) are regulated by proportional-integral controllers (PI) in a rotating coordinate system in which they are represented by dq-components. These components are direct quantities. A positive-negative-sequence current control (PNC) strategy is used to control the positive-sequence currents and the negative-sequence currents separately in two contra-rotating coordinate systems using PI-controllers. In contrast to the first two control strategies, frequency-selective current controllers (FSC) serve to regulate the currents in a static coordinate system. In this case the currents are represented by {alpha}{beta}-components which are alternating quantities. Combining the FSC and PNC strategies will produce frequencyselective positive-negative-sequence current controllers (FSC(PN)). These control the currents in a static coordinate system. The currents are represented by alternating {alpha}{beta}-components as in frequency-selective control but separate reference values for the negative-sequence currents are provided as in positive-negative-sequence control. Theoretical reasoning suggests and simulations prove that the three proposed alternative control strategies can improve the behaviour of DFIG-systems during slight asymmetries in the grid

  20. Spatial mapping of wind parks in Republic of Macedonia from aspect of power generation and connection to power grid

    International Nuclear Information System (INIS)

    Janchevska, Melita

    2012-01-01

    The master thesis “Spatial mapping of wind parks in Republic of Macedonia from aspect of power generation and connection to power grid” presents spatial aspects for setting of wind parks at favourable locations. The thesis presents a comprehensive analysis how to carry out the administrative procedures that are in force in Republic of Macedonia, a range of minimum allowed distances in setting of each of the wind plants within a wind parks, but also requirements for fulfilling the basic human rights in preserving quality of life of the people in rural areas where the wind parks are build. As a result, a compromise in setting of wind parks and a suitable solution of sustainable development should be reached. Therefore, the decision making process should be based on the following key factors: environmental, social and economic development of the area of concern. The production of wind power is strongly influenced by meteorological conditions and has an average factor of utilization of up to 30%. This low factor of utilization cannot be used for planning of the basic energy needs of the country, but it can contribute certainly towards the reduction of the participation of conventional power plants. Republic of Macedonia introduced feed-in tariffs as a subsiding mechanism for building and strong penetration of wind parks. Additional funding mechanisms include carbon financing and green-field credits, through development of projects in the framework of Clean Development Mechanism, which improves the economic feasibility of the project and increases the interest of the investors. The analysis of the relevant spatial aspects of setting wind parks in Republic of Macedonia based on balanced and sustainable spatial development is made with regards to the following thematic areas: exploiting the potential of wind energy, climate issues, geo morphological and geo seismically aspects, rational use of land, protection of agricultural land and forests, spatial allocation of

  1. Statistical analysis of simulation-generated time series : Systolic vs. semi-systolic correlation on the Connection Machine

    NARCIS (Netherlands)

    Dontje, T.; Lippert, Th.; Petkov, N.; Schilling, K.

    1992-01-01

    Autocorrelation becomes an increasingly important tool to verify improvements in the state of the simulational art in Latice Gauge Theory. Semi-systolic and full-systolic algorithms are presented which are intensively used for correlation computations on the Connection Machine CM-2. The

  2. IEEE Std 383-1974: IEEE standard for type test of Class IE electric cables, field splices, and connections for nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard provides direction for establishing type tests which may be used in qualifying Class 1E electric cables, field splices, and other connections for service in nuclear power generating stations. General guidelines for qualifications are given in IEEE Std 323-1974, Standard for Qualifying Class IE Electric Equipment for Nuclear Power Generating Stations. Categories of cables covered are those used for power control and instrumentation services. Though intended primarily to pertain to cable for field installation, this guide may also be used for the qualification of internal wiring of manufactured devices. This guide does not cover cables for service within the reactor vessel

  3. SPECIATION OF SELENIUM AND ARSENIC COMPOUNDS BY CAPILLARY ELECTROPHORESIS WITH HYDRODYNAMICALLY MODIFIED ELECTROOSMOTIC FLOW AND ON-LINE REDUCTION OF SELENIUM(VI) TO SELENIUM(IV) WITH HYDRIDE GENERATION INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRIC DETECTION

    Science.gov (United States)

    Capillary electrophoresis (CE) with hydride generation inductively coupled plasma mass spectrometry was used to determine four arsenicals and two selenium species. Selenate (SeVI) was reduced on-line to selenite (SeIV') by mixing the CE effluent with concentrated HCl. A microporo...

  4. Teacher induction

    NARCIS (Netherlands)

    Beijaard, D.; Buitink, J.; Kessels, C.; Peterson, P.; Baker, E.; McGraw, B.

    2010-01-01

    Teacher induction programs are intended to support the professional development of beginning teachers and thereby contribute to the reduction of teacher attrition during the early teaching years. Teacher induction programs are often based upon a deficit model with a focus on the better organization

  5. A Short-Term Outage Model of Wind Turbines with Doubly Fed Induction Generators Based on Supervisory Control and Data Acquisition Data

    Directory of Open Access Journals (Sweden)

    Peng Sun

    2016-10-01

    Full Text Available This paper presents a short-term wind turbine (WT outage model based on the data collected from a wind farm supervisory control and data acquisition (SCADA system. Neural networks (NNs are used to establish prediction models of the WT condition parameters that are dependent on environmental conditions such as ambient temperature and wind speed. The prediction error distributions are discussed and used to calculate probabilities of the operation of protection relays (POPRs that were caused by the threshold exceedance of the environmentally sensitive parameters. The POPRs for other condition parameters are based on the setting time of the operation of protection relays. The union probability method is used to integrate the probabilities of operation of each protection relay to predict the WT short term outage probability. The proposed method has been used for real 1.5 MW WTs with doubly fed induction generators (DFIGs. The results show that the proposed method is more effective in WT outage probability prediction than traditional methods.

  6. Development of novel and sensitive methods for the determination of sulfide in aqueous samples by hydrogen sulfide generation-inductively coupled plasma-atomic emission spectroscopy.

    Science.gov (United States)

    Colon, M; Todolí, J L; Hidalgo, M; Iglesias, M

    2008-02-25

    Two new, simple and accurate methods for the determination of sulfide (S(2-)) at low levels (microgL(-1)) in aqueous samples were developed. The generation of hydrogen sulfide (H(2)S) took place in a coil where sulfide reacted with hydrochloric acid. The resulting H(2)S was then introduced as a vapor into an inductively coupled plasma-atomic emission spectrometer (ICP-AES) and sulfur emission intensity was measured at 180.669nm. In comparison to when aqueous sulfide was introduced, the introduction of sulfur as H(2)S enhanced the sulfur signal emission. By setting a gas separator at the end of the reaction coil, reduced sulfur species in the form of H(2)S were removed from the water matrix, thus, interferences could be avoided. Alternatively, the gas separator was replaced by a nebulizer/spray chamber combination to introduce the sample matrix and reagents into the plasma. This methodology allowed the determination of both sulfide and sulfate in aqueous samples. For both methods the linear response was found to range from 5microgL(-1) to 25mgL(-1) of sulfide. Detection limits of 5microgL(-1) and 6microgL(-1) were obtained with and without the gas separator, respectively. These new methods were evaluated by comparison to the standard potentiometric method and were successfully applied to the analysis of reduced sulfur species in environmental waters.

  7. Optimization of a single-drop microextraction method for multielemental determination by electrothermal vaporization inductively coupled plasma mass spectrometry following in situ vapor generation

    International Nuclear Information System (INIS)

    Gil, Sandra; Loos-Vollebregt, Margaretha T.C. de; Bendicho, Carlos

    2009-01-01

    A headspace single-drop microextraction (HS-SDME) method has been developed in combination with electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) for the simultaneous determination of As, Sb, Bi, Pb, Sn and Hg in aqueous solutions. Vapor generation is carried out in a 40 mL volume closed-vial containing a solution with the target analytes in hydrochloric acid and potassium ferricyanide medium. Hydrides (As, Sb, Bi, Pb, Sn) and Hg vapor are trapped onto an aqueous single drop (3 μL volume) containing Pd(II), followed by the subsequent injection in the ETV. Experimental variables such as medium composition, sodium tetrahydroborate (III) volume and concentration, stirring rate, extraction time, sample volume, ascorbic acid concentration and palladium amount in the drop were fully optimized. The limits of detection (LOD) (3σ criterion) of the proposed method for As, Sb, Bi, Pb, Sn and Hg were 0.2, 0.04, 0.01, 0.07, 0.09 and 0.8 μg/L, respectively. Enrichment factors of 9, 85, 138, 130, 37 and 72 for As, Sb, Bi, Pb, Sn and Hg, respectively, were achieved in 210 s. The relative standard deviations (N = 5) ranged from 4 to 8%. The proposed HS-SDME-ETV-ICP-MS method has been applied for the determination of As, Sb, Bi, Pb, Sn and Hg in NWRI TM-28.3 certified reference material.

  8. Vibrational Dynamics of Interfacial Water by Free Induction Decay Sum Frequency Generation (FID-SFG) at the Al2O3(1120)/H2O Interface.

    Science.gov (United States)

    Boulesbaa, Abdelaziz; Borguet, Eric

    2014-02-06

    The dephasing dynamics of a vibrational coherence may reveal the interactions of chemical functional groups with their environment. To investigate this process at a surface, we employ free induction decay sum frequency generation (FID-SFG) to measure the time that it takes for free OH stretch oscillators at the charged (pH ≈ 13, KOH) interface of alumina/water (Al2O3/H2O) to lose their collective coherence. By employing noncollinear optical parametric amplification (NOPA) technology and nonlinear vibrational spectroscopy, we showed that the single free OH peak actually corresponds to two distinct oscillators oriented opposite to each other and measured the total dephasing time, T2, of the free OH stretch modes at the Al2O3/H2O interface with a sub-40 fs temporal resolution. Our results suggested that the free OH oscillators associated with interfacial water dephase on the time scale of 89.4 ± 6.9 fs, whereas the homogeneous dephasing of interfacial alumina hydroxyls is an order of magnitude slower.

  9. Evaluation of slurry preparation procedures for the determination of mercury by axial view inductively coupled plasma optical emission spectrometry using on-line cold vapor generation

    International Nuclear Information System (INIS)

    Santos, Eder Jose dos; Herrmann, Amanda Beatriz; Antunes Vieira, Mariana; Azzolin Frescura, Vera Lucia; Curtius, Adilson Jose

    2005-01-01

    Five different slurry preparation procedures were tested, after grinding the solid samples to a particle size ≤53 μm: (1) using aqua regia plus HF, 30 min of sonication, standing time of 24 h followed by another 30 min of sonication; (2) same as the previous one, except that the standing time and the second ultrasound treatment were omitted; (3) same as the previous one, except that HF was not used; (4) same as the previous one, except that the aqua regia was replaced by nitric acid; (5) same as the previous one, except that the acid nitric was replaced by tetramethylammonium hydroxide (TMAH). The Hg vapor was generated on-line, and the emission signal intensity measured at 253.652 nm by axial view inductively coupled plasma optical emission spectrometry. Initially, four experimental conditions were optimized using a multivariate factorial analysis: the concentrations of HCl and of the reducing agent, NaBH 4 , used in the cold vapor generation, and two instrumental parameters, the plasma radiofrequency power and the carrier gas flow rate. The radiofrequency power was statistically significant, but limited to 1.2 kW for practical reasons. The procedures were applied to 11 biological and environmental materials. Both, the slurries and the filtrates were analyzed, using calibration solutions in the same medium as in the slurries. The first three procedures produced results in agreement with the certified values. The two last procedures, using nitric acid or TMHA could not be used for quantitative analysis. For practical reasons, Procedure 3, with a detection limit (3s, n=10) of 0.06 μg g -1 for a sample mass of 20 mg in a final volume of 15 mL is recommended. The relative standard deviations for mercury in the investigated materials, using the recommended procedure, were lower than 12.5%, indicating a good precision for slurry sampling. The recommended procedure is simple, rapid and robust

  10. Slurry sampling flow injection chemical vapor generation inductively coupled plasma mass spectrometry for the determination of trace Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Wei-Ni [Department of Chemistry, National Sun Yat-sen University, Kaohsiung 80424, Taiwan (China); Jiang, Shiuh-Jen, E-mail: sjjiang@faculty.nsysu.edu.tw [Department of Chemistry, National Sun Yat-sen University, Kaohsiung 80424, Taiwan (China); Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung 80708, Taiwan (China); Chen, Yen-Ling [Department of Fragrance and Cosmetic Science, Kaohsiung Medical University, Kaohsiung 80708, Taiwan (China); Sahayam, A.C. [National Centre for Compositional Characterisation of Materials (CCCM), Hyderabad (India)

    2015-02-20

    Highlights: • Determination of Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions in a single run. • Accurate analysis using isotope dilution and standard addition methods. • Vapor generation ICP-MS yielded superior detection limits compared to ETV-ICP-MS. • No sample dissolution increased sample through put. • Analysis of GBW09305 Cosmetic (Cream) reference material for accuracy. - Abstract: A slurry sampling inductively coupled plasma mass spectrometry (ICP-MS) method has been developed for the determination of Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions using flow injection (FI) vapor generation (VG) as the sample introduction system. A slurry containing 2% m/v lotion, 2% m/v thiourea, 0.05% m/v L-cysteine, 0.5 μg mL{sup −1} Co(II), 0.1% m/v Triton X-100 and 1.2% v/v HCl was injected into a VG-ICP-MS system for the determination of Ge, As, Cd, Sb, Hg and Bi without dissolution and mineralization. Because the sensitivities of the analytes in the slurry and that of aqueous solution were quite different, an isotope dilution method and a standard addition method were used for the determination. This method has been validated by the determination of Ge, As, Cd, Sb, Hg and Bi in GBW09305 Cosmetic (Cream) reference material. The method was also applied for the determination of Ge, As, Cd, Sb, Hg and Bi in three cosmetic lotion samples obtained locally. The analysis results of the reference material agreed with the certified value and/or ETV-ICP-MS results. The detection limit estimated from the standard addition curve was 0.025, 0.1, 0.2, 0.1, 0.15, and 0.03 ng g{sup −1} for Ge, As, Cd, Sb, Hg and Bi, respectively, in original cosmetic lotion sample.

  11. Slurry sampling flow injection chemical vapor generation inductively coupled plasma mass spectrometry for the determination of trace Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions

    International Nuclear Information System (INIS)

    Chen, Wei-Ni; Jiang, Shiuh-Jen; Chen, Yen-Ling; Sahayam, A.C.

    2015-01-01

    Highlights: • Determination of Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions in a single run. • Accurate analysis using isotope dilution and standard addition methods. • Vapor generation ICP-MS yielded superior detection limits compared to ETV-ICP-MS. • No sample dissolution increased sample through put. • Analysis of GBW09305 Cosmetic (Cream) reference material for accuracy. - Abstract: A slurry sampling inductively coupled plasma mass spectrometry (ICP-MS) method has been developed for the determination of Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions using flow injection (FI) vapor generation (VG) as the sample introduction system. A slurry containing 2% m/v lotion, 2% m/v thiourea, 0.05% m/v L-cysteine, 0.5 μg mL −1 Co(II), 0.1% m/v Triton X-100 and 1.2% v/v HCl was injected into a VG-ICP-MS system for the determination of Ge, As, Cd, Sb, Hg and Bi without dissolution and mineralization. Because the sensitivities of the analytes in the slurry and that of aqueous solution were quite different, an isotope dilution method and a standard addition method were used for the determination. This method has been validated by the determination of Ge, As, Cd, Sb, Hg and Bi in GBW09305 Cosmetic (Cream) reference material. The method was also applied for the determination of Ge, As, Cd, Sb, Hg and Bi in three cosmetic lotion samples obtained locally. The analysis results of the reference material agreed with the certified value and/or ETV-ICP-MS results. The detection limit estimated from the standard addition curve was 0.025, 0.1, 0.2, 0.1, 0.15, and 0.03 ng g −1 for Ge, As, Cd, Sb, Hg and Bi, respectively, in original cosmetic lotion sample

  12. Effects of wake effect and time delay on output characteristics of doubly fed induction generators in wind power plant%尾流效应和时滞对双馈机组风电场输出特性的影响

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

      由于双馈机组已成为国内主流机型且大型双馈机组风电场通常占地面积比较大,需要研究双馈风电机组间的尾流效应及时滞对双馈机组风电场的并网点输出特性的影响情况。通过搭建了30台2 MW双馈风电机组组成的风电场模型,对风速波动和电网故障下双馈机组风电场输出特性进行分析和比较。通过仿真表明,机组间的尾流效应导致双馈机组风电场的风能损失;风速时滞平缓了风电场输出功率。%Because doubly fed induction generator has become the mainstream type and a large wind power plant usually covers a larger area,the impacts of wake effects among wind turbines and time delay on output characteristics of wind power plant need to be studied. With a wind power plant model composed of thirty 2⁃MW double fed induction generator wind tur⁃bines,the output characteristic of wind power plant under the conditions of wind speed fluctuation and grid faults is analyzed and compared. The simulation results show that the wake effects among wind turbines can cause the wind energy loss of wind farm and the wind speed time delay will smooth the power output of wind farm;wake effects among wind turbines and wind speed time delays needs to be considered when the grid⁃connection stability of wind farms with double fed induction generator wind turbines is analyzed.

  13. Transcranial direct current stimulation generates a transient increase of small-world in brain connectivity: an EEG graph theoretical analysis.

    Science.gov (United States)

    Vecchio, Fabrizio; Di Iorio, Riccardo; Miraglia, Francesca; Granata, Giuseppe; Romanello, Roberto; Bramanti, Placido; Rossini, Paolo Maria

    2018-04-01

    Transcranial direct current stimulation (tDCS) is a non-invasive technique able to modulate cortical excitability in a polarity-dependent way. At present, only few studies investigated the effects of tDCS on the modulation of functional connectivity between remote cortical areas. The aim of this study was to investigate-through graph theory analysis-how bipolar tDCS modulate cortical networks high-density EEG recordings were acquired before and after bipolar cathodal, anodal and sham tDCS involving the primary motor and pre-motor cortices of the dominant hemispherein 14 healthy subjects. Results showed that, after bipolar anodal tDCS stimulation, brain networks presented a less evident "small world" organization with a global tendency to be more random in its functional connections with respect to prestimulus condition in both hemispheres. Results suggest that tDCS globally modulates the cortical connectivity of the brain, modifying the underlying functional organization of the stimulated networks, which might be related to changes in synaptic efficiency of the motor network and related brain areas. This study demonstrated that graph analysis approach to EEG recordings is able to intercept changes in cortical functions mediated by bipolar anodal tDCS mainly involving the dominant M1 and related motor areas. Concluding, tDCS could be an useful technique to help understanding brain rhythms and their topographic functional organization and specificity.

  14. Comparison of 2D and 3D neural induction methods for the generation of neural progenitor cells from human induced pluripotent stem cells

    DEFF Research Database (Denmark)

    Chandrasekaran, Abinaya; Avci, Hasan; Ochalek, Anna

    2017-01-01

    Neural progenitor cells (NPCs) from human induced pluripotent stem cells (hiPSCs) are frequently induced using 3D culture methodologies however, it is unknown whether spheroid-based (3D) neural induction is actually superior to monolayer (2D) neural induction. Our aim was to compare the efficiency......), cortical layer (TBR1, CUX1) and glial markers (SOX9, GFAP, AQP4). Electron microscopy demonstrated that both methods resulted in morphologically similar neural rosettes. However, quantification of NPCs derived from 3D neural induction exhibited an increase in the number of PAX6/NESTIN double positive cells...... the electrophysiological properties between the two induction methods. In conclusion, 3D neural induction increases the yield of PAX6+/NESTIN+ cells and gives rise to neurons with longer neurites, which might be an advantage for the production of forebrain cortical neurons, highlighting the potential of 3D neural...

  15. Induction of Metallothionein Expression After Exposure to Conventional Cigarette Smoke but Not Electronic Cigarette (ECIG-Generated Aerosol in Caenorhabditis elegans

    Directory of Open Access Journals (Sweden)

    Eric Cobb

    2018-04-01

    Full Text Available Aim: With the invention of electronic cigarettes (ECIG, many questions have been raised regarding their safety as an alternative to smoking conventional cigarettes. Conventional cigarette smoke contains a variety of toxicants including heavy metals. However, ECIG-generated aerosol contains only trace amounts of metals, adding to the argument for it being a safer alternative. In response to heavy metal exposure, metallothioneins are induced in cells to help store the metal, detoxify the body, and are also known responders to oxidative stress. In an attempt to add to the evaluation of the safety of ECIGs, metallothionein expression was quantified using the nematode Caenorhabditis elegans as an assessment of stress induced cellular damage caused by exposure.Methods: Adult nematodes were exposed to either ECIG aerosol or conventional cigarette smoke at doses of 15, 30, and 45 puffs, the equivalent of one, two, and three cigarettes, respectively. Movement, survival, and stress-induced sleep were assessed for up to 24 h after exposure. Relative expression levels for mtl-1 and mtl-2, C. elegans metallothionein genes, were analyzed after 1, 5, and 24 h post exposure using quantitative RT-PCR.Results: Nematodes exposed to conventional cigarette smoke underwent stress-induced sleep in a dose dependent manner with animals recovering to values within the range of air control after 5 h post exposure. Those exposed to ECIG aerosol did not undergo stress-induced sleep and were indistinguishable from controls. The expression of mtl-1 increased in a dose and time dependent manner in C. elegans exposed to conventional cigarette smoke, with a maximum expression observed at 5 h post exposure of 45 puffs. No induction of mtl-2 was observed in any animals. Additionally, ECIG aerosol did not induce expression of mtl-1 and mtl-2 at levels different than those of untreated.Conclusion: ECIG aerosol failed to induce a stress response in C. elegans. In contrast

  16. Electrical system studies for the grid connection of wind farms

    International Nuclear Information System (INIS)

    Arp, K.; Hanson, J.; Hopp, S.; Zimmermann, W.

    2007-01-01

    Wind power is gaining momentum in the world's energy balance. Several issues have to be addressed whenever power-generating devices are connected to the grid. The paper describes studies needed to evaluate the influence of wind farms on the connected transmission system and how faults in the system impact on induction generators in a wind farm. Some generalized results of studies for an offshore wind farm in the North Sea and a Bulgarian wind farm show how studies can influence the layout of the internal network and the electrical equipment. (authors)

  17. Changes in Functional Connectivity Associated with Direct Training and Generalization Effects of a Theory-Based Generative Naming Treatment

    Directory of Open Access Journals (Sweden)

    Swathi Kiran

    2014-04-01

    Nine PWA improved on the trained abstract words; seven PWA also showed generalization to concrete words in the same context-category. The region with the highest node degree in the trained abstract network across PWA was left inferior frontal gyrus pars triangularis (L IFGtri; while the highest node degree in the generalized concrete network was left precentral gyrus. Regions that showed increased connectivity for both training and generalization included L IFGtri, right middle frontal gyrus (MFG, and bilateral angular gyrus. Regions that showed increased connectivity regardless of whether or not treatment was given and whether or not treatment was successful included left MFG and bilateral superior frontal gyrus. Additionally, PWA who generalized showed more left than right hemisphere changes in both abstract and concrete networks; while PWA who improved on the trained abstract words, but did not generalize to concrete words showed more left than right hemisphere changes for the abstract network, but more right than left hemisphere changes for the concrete network. These results suggest that (a direct training and generalization are tapping into similar neural mechanisms, and (b changes in the left hemisphere coincide with better treatment outcomes.

  18. Development of novel and sensitive methods for the determination of sulfide in aqueous samples by hydrogen sulfide generation-inductively coupled plasma-atomic emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Colon, M. [Department of Chemistry, University of Girona, Campus Montilivi, 17071 Girona (Spain); Departamento de Quimica Analitica, Nutricion y Bromatologia, University of Alicante, 03080 Alicante (Spain); Todoli, J.L. [Departamento de Quimica Analitica, Nutricion y Bromatologia, University of Alicante, 03080 Alicante (Spain); Hidalgo, M. [Department of Chemistry, University of Girona, Campus Montilivi, 17071 Girona (Spain); Iglesias, M. [Department of Chemistry, University of Girona, Campus Montilivi, 17071 Girona (Spain)], E-mail: monica.iglesias@udg.es

    2008-02-25

    Two new, simple and accurate methods for the determination of sulfide (S{sup 2-}) at low levels ({mu}g L{sup -1}) in aqueous samples were developed. The generation of hydrogen sulfide (H{sub 2}S) took place in a coil where sulfide reacted with hydrochloric acid. The resulting H{sub 2}S was then introduced as a vapor into an inductively coupled plasma-atomic emission spectrometer (ICP-AES) and sulfur emission intensity was measured at 180.669 nm. In comparison to when aqueous sulfide was introduced, the introduction of sulfur as H{sub 2}S enhanced the sulfur signal emission. By setting a gas separator at the end of the reaction coil, reduced sulfur species in the form of H{sub 2}S were removed from the water matrix, thus, interferences could be avoided. Alternatively, the gas separator was replaced by a nebulizer/spray chamber combination to introduce the sample matrix and reagents into the plasma. This methodology allowed the determination of both sulfide and sulfate in aqueous samples. For both methods the linear response was found to range from 5 {mu}g L{sup -1} to 25 mg L{sup -1} of sulfide. Detection limits of 5 {mu}g L{sup -1} and 6 {mu}g L{sup -1} were obtained with and without the gas separator, respectively. These new methods were evaluated by comparison to the standard potentiometric method and were successfully applied to the analysis of reduced sulfur species in environmental waters.

  19. Control of offshore wind farms with HVDC grid connection

    Energy Technology Data Exchange (ETDEWEB)

    Weigel, Stefan; Weise, Bernd; Poeller, Markus [DIgSILENT GmbH, Gomaringen (Germany)

    2010-07-01

    This paper analyzes various aspects related to the operation of HVDC connected offshore wind farms. The main interest is on the behavior during on- and offshore faults. Different control strategies for VSC-HVDC and ''classical'' thyristor-based HVDC links are presented and analyzed via network simulations. Wind generators with fully-rated converters and wind generators with doubly-fed induction generators are considered as generator types. The feasibility, advantages and disadvantages of the various options are discussed in detail. (orig.)

  20. Sampling Assumptions in Inductive Generalization

    Science.gov (United States)

    Navarro, Daniel J.; Dry, Matthew J.; Lee, Michael D.

    2012-01-01

    Inductive generalization, where people go beyond the data provided, is a basic cognitive capability, and it underpins theoretical accounts of learning, categorization, and decision making. To complete the inductive leap needed for generalization, people must make a key "sampling" assumption about how the available data were generated.…

  1. From Inductive Reasoning to Proof

    Science.gov (United States)

    Yopp, David A.

    2009-01-01

    Mathematical proof is an expression of deductive reasoning (drawing conclusions from previous assertions). However, it is often inductive reasoning (conclusions drawn on the basis of examples) that helps learners form their deductive arguments, or proof. In addition, not all inductive arguments generate more formal arguments. This article draws a…

  2. A reduced switch count UPF power conditioner for grid connected variable speed wind energy conversion system employing PM generators: a simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Raju, A.B.; Fernandes, B.G.; Chatterjee, K. [Indian Institute of Technology, Mumbai (India). Dept. of Electrical Engineering

    2004-07-01

    In this paper, modelling and simulation of a grid connected variable speed wind energy conversion system (VSWECS) with reduced switch count power converter is presented. The system consists of a permanent magnet synchronous generator (PMSG), two-pulse width modulated B-4 power converters and a maximum power point tracker (MPPT). Mathematical models of each element of the system are developed separately and are then integrated to simulate the whole system for various wind velocities. The complete system is simulated using MATLAB/SIMULINK and simulation results are presented. (author)

  3. Generating Units

    Data.gov (United States)

    Department of Homeland Security — Generating Units are any combination of physically connected generators, reactors, boilers, combustion turbines, and other prime movers operated together to produce...

  4. A dynamic power management strategy of a grid connected hybrid generation system using wind, photovoltaic and Flywheel Energy Storage System in residential applications

    International Nuclear Information System (INIS)

    Boukettaya, Ghada; Krichen, Lotfi

    2014-01-01

    A global supervisory strategy for a micro-grid power generation system that comprises wind and photovoltaic generation subsystems, a flywheel storage system, and domestic loads connected both to the hybrid power generators and to the grid, is developed in this paper. The objectives of the supervisor control are, firstly, to satisfy in most cases the load power demand and, secondly, to check storage and grid constraints to prevent blackout, to reduce energy costs and greenhouse gas emissions, and to extend the life of the flywheel. For these purposes, the supervisor determines online the operation mode of the different generation subsystems, switching from maximum power conversion to power regulation. Decision criteria for the supervisor based on actual variables are presented. Finally, the performance of the supervisor is extensively assessed through computer simulation using a comprehensive nonlinear model of the studied system. - Highlights: • We supervise a micro-grid power generation system with an objective to produce clipping grid consumption. • The supervisor switch online from maximum power conversion to power regulation. • We provide services both for domestic users and for the distribution network manager. • The developed algorithm is tested and validated for different scenarios

  5. Design of DC-DC Converter and its Control for a Wind Generation System Connected to an Isolated Load

    Directory of Open Access Journals (Sweden)

    Carlos A. Ramírez Gómez

    2013-11-01

    Full Text Available A method to design a Buck converter and its control, which are associated to a wind generation system that is feeding an isolated load, is presented in this paper. To design the converter a Thevenin equivalent is deduced, which represents the behavior of the wind turbine, the permanent magnet synchronous generator, and the rectifier. The design of the converter elements guarantees input/output voltages and inductor current ripples of 5 % or less. The output voltage control is developed with a proportional-integral-derivative controller and as design criteria a damping of 0,707 and cutoff frequency of 1/5 converter commutation frequency are selected. The designed controller regulates the output voltage faced load perturbations and wind speed variations. 

  6. A new estimation method of irradiance on a partially shaded PV generator in grid-connected photovoltaic systems

    Energy Technology Data Exchange (ETDEWEB)

    Drif, M. [Grupo de Investigacion IDEA, Departamento de Electronica, Escuela Politecnica Superior, Universidad de Jaen, Campus Las Lagunillas, 23071 Jaen (Spain); Centre de Developpement des Energies Renouvelables, BP 62, Route de l' Observatoire, 16340 Bouzareah, Algiers (Algeria); Perez, P.J.; Aguilera, J.; Aguilar, J.D. [Grupo de Investigacion IDEA, Departamento de Electronica, Escuela Politecnica Superior, Universidad de Jaen, Campus Las Lagunillas, 23071 Jaen (Spain)

    2008-09-15

    A new method for estimating the irradiance on a partially shaded photovoltaic generator system is proposed. The basic principle of this method consists of two parts: firstly, an approximation of the obstacles' outline or the local horizon by a set of linear functions. Here, a survey of the surroundings is based on the reading of the topographic coordinates of the only significant points of all the objects surrounding the photovoltaic generator. Secondly, the irradiance on the photovoltaic plane is estimated using an accurate model such as the Perez et al. model and assuming that the shading affects both the direct radiation and a part of the diffuse component (circumsolar component). The aim of this paper is to present the principles of the proposed method and the algorithm used for calculating the irradiance on shaded planes. In addition, the results of the comparison between the simulated and measured values of this method are presented. (author)

  7. 双馈风电机组与高速永磁风电机组对比分析﹡%Comparison of Doubly-fed Induction Generator and High Speed Permanent Magnet Wind Power Generator

    Institute of Scientific and Technical Information of China (English)

    2013-01-01

    is paper compared two main wind turbines. One is doubly-fed induction generator, the other is high speed permanent magnet wind power generator. It calculated the efficiency and annual electric energy production in different IEC wind classes, and compared the cost based on the market value. A er analyzing the reliability, e ciency and power grid adaptability, it came to the conclusion that two types of wind turbines have di erent advantages and meet di erent requirements from customers. erefore, development of two types of wind turbines will be be er adapted to the market competition.%  本文从风电机组角度对两种主流的发电方式,即双馈式发电机组和高速永磁发电机组,进行了对比分析。计算了两种发电方式的效率及在不同风区的年发电量,根据市场价格对各部件进行成本对比。在综合考虑了可靠性、效率、电网适应性等方面后指出,两种方式各有特点,适合客户的不同需求。因此,作为风电机组开发商,同时开发两种机型方能更好地适应市场的竞争。

  8. Optimisation of intense X-ray sources of Z-pinch type connected to the high intensity current generator SPHINX

    International Nuclear Information System (INIS)

    Calamy, H.; Lassalle, F.; Grunenwald, J.; Zucchini, F.

    2010-01-01

    A new source of intense X-rays in the spectral range of the keV has been designed in the CEA facilities at Gramat (France). This Z-pinch source is based on the implosion of a cylinder of matter that has been ionized by the Lorentz force generated by the injection in the cylinder of an intense current pulse delivered by a HPP (High Pulsed Powers) generator named SPHINX. The cylinder of matter is made up of a few hundreds of thin metal wires (tungsten or aluminium) whose diameter is less than a few tenths of μm. The SPHINX generator is based on the LTD (Linear Transformer Driver) technology. SPHINX stores an energy of 2.2 MJ and delivers a current of 8 MA over a time of 1 μs. SPHINX does not use any technology of time compression, it is a robust, compact machine with reduced maintenance but the price to pay for this simplification is to maintain a high axial homogeneity of the implosion during the initiation phase, it means the pulse time of 1μs. The preliminary experiments that have been performed give the following results: -) for a tungsten cylinder (X ray 1 keV): 28 kJ, 0.6 TW and 25 ns

  9. The role of grid-connected, building-integrated photovoltaic generation in commercial building energy and power loads in a warm and sunny climate

    International Nuclear Information System (INIS)

    Braun, P.; Ruether, R.

    2010-01-01

    For large commercial buildings, power load delivery limits are contracted with the local electricity distribution utility, and are usually fixed at one or more levels over the year, according to the seasonal building loads, and depending on the specific country regulations. Especially in warm and sunny climates, solar electricity generation using building-integrated photovoltaics (BIPV) can assist in reducing commercial building loads, offering peak-shaving (power) benefits on top of the on-site generation of electricity (energy). This on-site power delivery capability gives these consumers the possibility of renegotiating demand contracts with their distribution utility. Commercial buildings that operate during daytime quite often have an energy consumption profile that is well matched by solar radiation availability, and depending on the building's available surface areas, BIPV can generate considerable portions of the energy requirements. In this work we present the role of grid-connected BIPV in reducing the load demands of a large and urban commercial building located in a warm climate in Brazil. The building and adjacent car parking lots can accommodate a 1 MWp BIPV generator, which closely matches the building's typical maximum power demands. Based on real solar radiation data and simultaneous building electricity demands for the year 2007, simulation of the annual solar generation profile of this on-site generator showed that the 1 MWp BIPV system could account for around 30% of the total building's energy consumption. In addition to the energy benefit, maximum power demands were reduced due to a good match between midday air-conditioning cooling loads and solar radiation availability on both a daily and seasonal basis. Furthermore, we have simulated the effect of this considerably large urban-sited generator on the local distribution network load, and have shown that the 1 MWp BIPV installation can also offer considerable benefits to the local utility in

  10. Effect of Short-Circuit Faults in the Back-to-Back Power Electronic Converter and Rotor Terminals on the Operational Behavior of the Doubly-Fed Induction Generator Wind Energy Conversion System

    Directory of Open Access Journals (Sweden)

    Dimitrios G. Giaourakis

    2015-02-01

    Full Text Available This paper deals with the operational behavior of the Doubly-Fed Induction Generator Wind Energy Conversion System under power electronic converter and rotor terminals faulty conditions. More specifically, the effect of the short-circuit fault both in one IGBT of the back-to-back power electronic converter and in rotor phases on the overall system behavior has been investigated via simulation using a system of 2 MW. Finally, the consequences of these faults have been evaluated.

  11. Influence of generated harmonics in the performance of three-phase induction motor using chopper in the rotor circuit; Influencia dos harmonicos gerados no desempenho do motor de inducao trifasico utilizando chopper no circuito rotorico

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Antonio Tadeu Lyrio de; Sa, Jocelio Souza de; Abreu, Jose Policarpo G. de; Lamoglia, Jose Augusto [Escola Federal de Engenharia de Itajuba, MG (Brazil). Dept. de Engenharia e Tecnologia

    1988-12-31

    One of the alternatives for the speed control of an induction motor is the insertion of a converter regulator of direct current (chopper) in the rotor. The utilization of a rectifier bridge in this circuit generates electric current harmonics. This work analyses its influence on the motor performance. The general equating, whenever possible, is based on the national manufactures catalogue data 2 refs., 6 figs.

  12. KOVEC studies of radioisotope thermoelectric generator response (In connection with possible NASA space shuttle accident explosion scenarios)

    Energy Technology Data Exchange (ETDEWEB)

    Walton, J.; Weston, A.; Lee, E.

    1984-06-26

    The Department of Energy (DOE) commissioned a study leading to a final report (NUS-4543, Report of the Shuttle Transportation System (STS) Explosion Working Group (EWG), June 8, 1984), concerned with PuO/sub 2/ dispersal should the NASA space shuttle explode during the proposed Galileo and ISPN launches planned for 1986. At DOE's request, LLNL furnished appendices that describe hydrocode KOVEC calculations of potential damage to the Radioisotope Thermoelectric Generators, fueled by PuO/sub 2/, should certain explosion scenarios occur. These appendices are contained in this report.

  13. Photovoltaic solar system connected to the electric power grid operating as active power generator and reactive power compensator

    Energy Technology Data Exchange (ETDEWEB)

    Albuquerque, F.L.; Moraes, A.J.; Guimaraes, G.C.; Sanhueza, S.M.R.; Vaz, A.R. [Federal University of Uberlandia (UFU), MG (Brazil)

    2009-07-01

    In the case of photovoltaic solar systems (PV) acting as a distributed generation (DG), the DC energy obtained is fed through the power-conditioning unit (inverter) to the grid. The majority of contemporary inverters used in DG systems are current source inverters (CSI) operating at unity power factor. If, however, we assume that voltage source inverters (VSI) can be utilized instead of CSI, we can generate reactive power commensurate with the remaining unused capacity at any given point in time. According to the theory of instantaneous power, the reactive and active power of inverter can be regulated by changing the amplitude and the phase of the output voltage of the inverter. Based on this theory, the active power output and the reactive power compensation (RPC) of the system are realized simultaneously. When the insolation is weak or the PV modules are inoperative at night, the RPC feature of PV system can still be used to improve the utilization factor of the inverter. The MATLAB simulation results validate the feasibility of the method. (author)

  14. A survey of the ESI connection arrangements and scale of power benefits offered to embedded generators in England and Wales

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-11-01

    In order to establish whether there is potential for a longer term future for renewable and other embedded generation in the UK, it is necessary to ensure that no undue bias exists which might inhibit the natural growth of this emerging industry. As a part of this process, it is necessary to examine the attitudes and policies of the Regional Electricity Companies (RECs) to these developments. Developers, operating on a 'level playing field' with the Electricity Supply Industry should have a reasonable expectation of: fair and reasonable terms for the concoction of their equipment to the REC network, the opportunity of negotiating a reasonable price with the REC Supply business for their product - having regard to the fact that the RECs are obliged by the terms of their licence, to make economic purchases of energy, and broadly similar treatment - one REC to another, accepting the fact that embedded energy might have different worth in different parts of the UK. West Green Associates were asked to systematically approach REC in England and Wales in order to establish the attitudes and policies of the RECs towards embedded generation. (author)

  15. Seismic and Power Generation Performance of U-Shaped Steel Connected PV-Shear Wall under Lateral Cyclic Loading

    Directory of Open Access Journals (Sweden)

    Hongmei Zhang

    2014-01-01

    Full Text Available BIPV is now widely used in office and residential buildings, but its seismic performance still remained vague especially when the photovoltaic (PV modules are installed on high-rise building facades. A new form of reinforced concrete shear wall integrated with photovoltaic module is proposed in this paper, aiming to apply PV module to the facades of high-rise buildings. In this new form, the PV module is integrated with the reinforced concrete wall by U-shaped steel connectors through embedded steel plates. The lateral cyclic loading test is executed to investigate the seismic behavior and the electric and thermal performance with different drift angles. The seismic behavior, including failure pattern, lateral force-top displacement relationship, and deformation capacity, was investigated. The power generation and temperature variation on the back of the PV module and both sides of the shear wall were also tested. Two main results are demonstrated through the experiment: (1 the U-shaped steel connectors provide enough deformation capacity for the compatibility of the PV module to the shear wall during the whole cyclic test; (2 the electricity generation capacity is effective and stable during this seismic simulation test.

  16. Induction practice -

    DEFF Research Database (Denmark)

    Rohde, Nicolas; Sprogøe, Jonas

    2007-01-01

    that induction potentially triggers both individual and organizational learning and by drawing on practice-based theory we discuss how the interplay between individual and the organization, what we call agenerative dance, ignites both kinds of learning. We focus on and describe the interplay , ignites both kinds...

  17. Comparative oxidation state specific analysis of arsenic species by high-performance liquid chromatography-inductively coupled-mass spectrometry and hydride generation-cryotrapping-atomic absorption spectrometry

    Science.gov (United States)

    The formation of methylarsonous acid (MAsIII) and dimethylarsinous acid (DMAsIII) in the course of inorganic arsenic (iAs) metabolism plays an important role in the adverse effects of chronic exposure to iAs. High-performance liquid chromatography-inductively coupled plasma-mass ...

  18. Induction Brazing

    DEFF Research Database (Denmark)

    Henningsen, Poul

    , or if the hottest area is located outside the joint interface, a number of defects may appear: the braze metal may flow away from the joint, the flux may burn off, poor binding of the braze metal may appear or the braze metal may be overheated. Joint geometry as well as electro-magnetic properties of the work piece...... presents a combined numerical and experimental method for determination of appropriate/optimiged coil geometry and position in induction brazing tube-to-plate joints of different ratios between tube and plate thickness and different combinations of the materials stainless steel, brass and copper....... The method has proven to give successful results in brazing tube-plate joints of copper-brass, copper-stainless steel, stainless steel-brass, and stainless steel-stainless steel. A new design of an adjustable flux concentrator for induction heating tube-to-plate joints is proposed and tested on a variety...

  19. Object detection approach using generative sparse, hierarchical networks with top-down and lateral connections for combining texture/color detection and shape/contour detection

    Science.gov (United States)

    Paiton, Dylan M.; Kenyon, Garrett T.; Brumby, Steven P.; Schultz, Peter F.; George, John S.

    2015-07-28

    An approach to detecting objects in an image dataset may combine texture/color detection, shape/contour detection, and/or motion detection using sparse, generative, hierarchical models with lateral and top-down connections. A first independent representation of objects in an image dataset may be produced using a color/texture detection algorithm. A second independent representation of objects in the image dataset may be produced using a shape/contour detection algorithm. A third independent representation of objects in the image dataset may be produced using a motion detection algorithm. The first, second, and third independent representations may then be combined into a single coherent output using a combinatorial algorithm.

  20. Object detection approach using generative sparse, hierarchical networks with top-down and lateral connections for combining texture/color detection and shape/contour detection

    Energy Technology Data Exchange (ETDEWEB)

    Paiton, Dylan M.; Kenyon, Garrett T.; Brumby, Steven P.; Schultz, Peter F.; George, John S.

    2016-10-25

    An approach to detecting objects in an image dataset may combine texture/color detection, shape/contour detection, and/or motion detection using sparse, generative, hierarchical models with lateral and top-down connections. A first independent representation of objects in an image dataset may be produced using a color/texture detection algorithm. A second independent representation of objects in the image dataset may be produced using a shape/contour detection algorithm. A third independent representation of objects in the image dataset may be produced using a motion detection algorithm. The first, second, and third independent representations may then be combined into a single coherent output using a combinatorial algorithm.

  1. Induction technology optimization code

    International Nuclear Information System (INIS)

    Caporaso, G.J.; Brooks, A.L.; Kirbie, H.C.

    1992-01-01

    A code has been developed to evaluate relative costs of induction accelerator driver systems for relativistic klystrons. The code incorporates beam generation, transport and pulsed power system constraints to provide an integrated design tool. The code generates an injector/accelerator combination which satisfies the top level requirements and all system constraints once a small number of design choices have been specified (rise time of the injector voltage and aspect ratio of the ferrite induction cores, for example). The code calculates dimensions of accelerator mechanical assemblies and values of all electrical components. Cost factors for machined parts, raw materials and components are applied to yield a total system cost. These costs are then plotted as a function of the two design choices to enable selection of an optimum design based on various criteria. (Author) 11 refs., 3 figs

  2. Investigation of stability and x-ray spectrum in gas-puff z-pinch plasmas diriven by inductive energy storage pulsed power generator with a plasma opening switch

    Energy Technology Data Exchange (ETDEWEB)

    Murayama, K.; Fukudome, I. [Yatsushiro National College of Technology, Dept. of Mechanical and Electrical Engineering, Yatsushiro, Kumamoto (Japan); Teramoto, Y.; Katsuki, S.; Akiyama, H. [Kumamoto Univ., Dept. of Electrical and Computer Engineering, Kumamoto (Japan)

    2002-06-01

    Gas-puff z-pinch plasmas are driven by an inductive voltage adder - inductive energy storage pulsed power generator ''ASO-X''. ASO-X has the performance of the maximum output voltage and current are 180 kV and 400 kA respectively and can provide a fast rise time current with operating POS. The stability of the plasma column, spectrum radiated from z-pinch plasmas and the spatial distribution of hot spots are investigated in the case with and without operating POS. By driving ASO-X with operating POS the kink instability is restrained and the stability of plasma column is improved about three times in regard to the average dispersion. Furthermore the duration of soft x-ray radiation is increased and the spatial distribution of hot spots is 50% improved with regard to kurtosis of the intensity profile of pinhole photographs compared to those without operating POS. (author)

  3. Investigation of stability and x-ray spectrum in gas-puff z-pinch plasmas diriven by inductive energy storage pulsed power generator with a plasma opening switch

    International Nuclear Information System (INIS)

    Murayama, K.; Fukudome, I.; Teramoto, Y.; Katsuki, S.; Akiyama, H.

    2002-01-01

    Gas-puff z-pinch plasmas are driven by an inductive voltage adder - inductive energy storage pulsed power generator ''ASO-X''. ASO-X has the performance of the maximum output voltage and current are 180 kV and 400 kA respectively and can provide a fast rise time current with operating POS. The stability of the plasma column, spectrum radiated from z-pinch plasmas and the spatial distribution of hot spots are investigated in the case with and without operating POS. By driving ASO-X with operating POS the kink instability is restrained and the stability of plasma column is improved about three times in regard to the average dispersion. Furthermore the duration of soft x-ray radiation is increased and the spatial distribution of hot spots is 50% improved with regard to kurtosis of the intensity profile of pinhole photographs compared to those without operating POS. (author)

  4. Inductive circuit arrangements

    International Nuclear Information System (INIS)

    Mansfield, Peter; Coxon, R.J.

    1987-01-01

    A switched coil arrangement is connected in a bridge configuration of four switches S 1 , S 2 , S 3 and S 4 which are each shunted by diodes D 1 , D 2 , D 3 and D 4 so that current can flow in either direction through a coil L depending on the setting of the switches. A capacitor C is connected across the bridge through a switch S 5 to receive the inductive energy stored in coil L on breaking the current flow path through the coil. The electrostatic energy stored in capacitor C can then be used to supply current through the coil in the reverse direction either immediately or after a time delay. Coil L may be a superconductive coil. Losses in the circuit can be made up by a trickle charge of capacitor C from a separate supply V 2 . The device may be used in nuclear magnetic resonance imaging. (author)

  5. Development of hybrid frequency couplers for non-inductive current drive in a tokamak; Developpement de coupleurs a la frequence hybride pour la generation non inductive du courant dans un tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Berio, St.

    1996-11-04

    Used at its first time as an heating method in order to reach the temperature requisite for the fusion of a thermonuclear plasma, the hybrid waves has shown that they were the more efficient method for non-inductive current drive in a tokamak. The size and the objectives of a next machine such as ITER lead of the design of new antennae (in process of realisation on Tore Supra) made of oversized waveguides. This new concept of antenna will be more simple, more robust and will be able to transmit the same if not much power than the present antennae. This thesis contribute to the development of a new code called ALOHA (for `Advanced LOwer Hybrid Antenna`) which, at the end, will be able to give the characteristics and the behaviours of this new oversized antennae in front of a tokamak plasma. This thesis is also a first step in the interpretation of some experimental data concerning the measurement of coupling, absorption and current drive of the actual hybrid wave launched by a grill with rectangular waveguides. Moreover, this thesis lay some foundations of the study of these new antennae in front of a non-parallel confinement magnetic field and/or in front of poloidal inhomogeneities of plasma. (author). 53 refs.

  6. Resolution 147/012. It authorize the Central Libertador / SA aeolian generation company to generate an aeolian electricity source by an electric power generating plant located in Maldonado town 4 AA Catastral section, and the Sistema inerconectado Nacional connection

    International Nuclear Information System (INIS)

    2012-01-01

    This decree authorizes the generation of electricity using aeolian energy as the primary electricity source. This project was presented by the 'Libertador / S.A' aeolian generation company with the proposal to install an electrical plant in Maldonado town. This authorization is according to the Electric Wholesale Market regulation

  7. Analisis Motor Induksi Fasa Tiga Tipe Rotor Sangkar Sebagai Generator Induksi Dengan Variasi Hubungan Kapasitor Untuk Eksitasi

    Directory of Open Access Journals (Sweden)

    Rahmi Berlianti

    2015-03-01

    Full Text Available Three-phase induction motor can be operated as a three-phase induction generator.The tendency to use induction generators (rotor cage as subtitute of a synchronous generator is also increasing, especially for small MHP with lighting load (resistive. Its because of the dificulty, hard to find in the market, and high cost,induction generator self-excitation has many advantages than synchronous generator. However, the induction generator offers low voltage regulation and its value depends on the driving speed, capacitors, and the load. In this study, a three-phase induction motor ( rotor cage 0.9 KW, 2.7 A, pf 0.84, 50 Hz used as an induction generator, with capasitor connection variety, which capasitance value for star 25μF , Delta 8μF, C-2C 8μF and 16μF to load R-RL varied. And star connection capasitor with 25μF capasitance is better than others.

  8. Overview of Bearingless Induction Motors

    Directory of Open Access Journals (Sweden)

    Xiaodong Sun

    2014-01-01

    Full Text Available Bearingless induction motors combining functions of both torque generation and noncontact magnetic suspension together have attracted more and more attention in the past decades due to their definite advantages of compactness, simple structure, less maintenance, no wear particles, high rotational speed, and so forth. This paper overviews the key technologies of the bearingless induction motors, with emphasis on motor topologies, mathematical models, and control strategies. Particularly, in the control issues, the vector control, independent control, direct torque control, nonlinear decoupling control, sensorless control, and so forth are investigated. In addition, several possible development trends of the bearingless induction motors are also discussed.

  9. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1996-04-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at LLNL from the early 1960's to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400 ns pulses. The Advanced Test Accelerator (ATA) built at Livermore's Site 300 produced 10,000 Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and LBNL. This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high current, short pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail

  10. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1997-01-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at Lawrence Livermore National Laboratory (LLNL) from the early 1960s to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400-ns pulses. The Advanced Test Accelerator (ATA) built at Livermore close-quote s Site 300 produced 10,000-Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and Lawrence Berkeley National Laboratory (LBNL). This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high-current, short-pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail. copyright 1997 American Institute of Physics

  11. A Steady-State Analysis Method for Modular Multilevel Converters Connected to Permanent Magnet Synchronous Generator-Based Wind Energy Conversion Systems

    Directory of Open Access Journals (Sweden)

    Zhijie Liu

    2018-02-01

    Full Text Available Modular multilevel converters (MMCs have shown great potential in the area of multi-megawatt wind energy conversion system (WECS based on permanent magnet synchronous generators (PMSGs. However, the studies in this area are few, and most of them refer to the MMC used in high-voltage direct current (HVDC systems, and hence the characteristics of the PMSG are not considered. This paper proposes a steady-state analysis method for MMCs connected to a PMSG-based WECS. In the proposed method, only the wind speed (operating condition is required as input, and all the electrical quantities in the MMC, including the amplitudes, phase angles and their harmonics, can be calculated step by step. The analysis method is built on the proposed d-q frame mathematical model. Interactions of electrical quantities between the MMC and PMSG are comprehensively considered. Moreover, a new way to calculate the average switching functions are adopted in order to improve the accuracy of the analysis method. Applications of the proposed method are also presented, which includes the characteristic analysis of capacitor voltage ripples and the capacitor sizing. Finally, the accuracy of the method and the correctness of the analysis are verified by simulations and experiments.

  12. Connective tissue growth factor linked to the E7 tumor antigen generates potent antitumor immune responses mediated by an antiapoptotic mechanism.

    Science.gov (United States)

    Cheng, W-F; Chang, M-C; Sun, W-Z; Lee, C-N; Lin, H-W; Su, Y-N; Hsieh, C-Y; Chen, C-A

    2008-07-01

    A novel method for generating an antigen-specific cancer vaccine and immunotherapy has emerged using a DNA vaccine. However, antigen-presenting cells (APCs) have a limited life span, which hinders their long-term ability to prime antigen-specific T cells. Connective tissue growth factor (CTGF) has a role in cell survival. This study explored the intradermal administration of DNA encoding CTGF with a model tumor antigen, human papilloma virus type 16 E7. Mice vaccinated with CTGF/E7 DNA exhibited a dramatic increase in E7-specific CD4(+) and CD8(+) T-cell precursors. They also showed an impressive antitumor effect against E7-expressing tumors compared with mice vaccinated with the wild-type E7 DNA. The delivery of DNA encoding CTGF and E7 or CTGF alone could prolong the survival of transduced dendritic cells (DCs) in vivo. In addition, CTGF/E7-transduced DCs could enhance a higher number of E7-specific CD8(+) T cells than E7-transduced DCs. By prolonging the survival of APCs, DNA vaccine encoding CTGF linked to a tumor antigen represents an innovative approach to enhance DNA vaccine potency and holds promise for cancer prophylaxis and immunotherapy.

  13. The effect of X-irradiation on the fertility and on the induction of meiotic chromosome rearrangements in mice and their first generation

    International Nuclear Information System (INIS)

    Savkovic, N.; Pecevski, J.; Maric, N.; Radivojevic, D.

    1980-01-01

    The effect of whole-body or local irradiation with X-rays at a dose of 600 R on the induction of chromosomal translocations in the diakinesis metaphase I of the meiosis in treated and F 1 males has been examined along with their fertility. Our results show the high percentage of mortality in whole-body irradiated mice. The percentage of the fertility was 25% in whole-body, and 93.7% in locally irradiated males. The testis weight was also reduced. The percentage of chromosomal translocations in diakinesis, metaphase I, of the meiosis was higher after whole-body irradiation than after local irradiation. In F 1 males both types of irradiation induced chromosomal translocations. (orig.) [de

  14. The effect of X-irradiation on the fertility and the induction of meiotic chromosome rearrangements in mice and their first generation

    International Nuclear Information System (INIS)

    Savkovic, N.; Pecevski, J.; Maric, N.; Radivojevic, D.

    1978-01-01

    The effect of whole-body and local irradiation with a dose of 600 X-rays on the induction of chromosomal translocations in Diakinesis-Metaphase I of meiosis in treated and F 1 males and their fertility have been examined. Our results showed the high percentage of mortality in whole-body irradiated mice. The percentage of fertility was 25% in whole-body, and 93,7% in locally irradiated males. The testis weight was also reduced. The percentage of chromosomal translocations in Diakinesis-Metaphase I of meiosis was greater after whole-body than after local irradiation. In F 1 males both types of irradiation induced chromosomal translocations. (orig.) [de

  15. Development of a module combustor biomass-motor Stirling applied to a isolated generation system and based on induction generator; Desenvolvimento de um modulo combustor biomassa-motor Stirling aplicado a sistemas de geracao isolada e baseados em gerador de inducao

    Energy Technology Data Exchange (ETDEWEB)

    Wilke, Humberto; Lora, Electo Eduardo Silva [Universidade Federal de Itajuba (UNIFEI), MG (Brazil). Nucleo de Excelencia em Geracao Termeletrica e Distribuida

    2004-07-01

    In some areas in Brazil the great distance of the generating and consuming centers, together with the low consumption of electric energy of these areas, they make unfeasible investments with transmission and distribution. The use of the biomass as fuel in the distributed generation, is low pollutions, it is renewable, besides possessing a low cost when compared to the fossil fuels [Barros, 2003]. By the way the generation distributed through renewable fuels, becomes an attractive solution for generation in distant and isolated areas of the electric system. Inside of this context, this paper proposes the use of a module combustor, biomass-motor Stirling, based on induction generator, applied to isolated areas, such as the north and northeast areas of the Brazil. (author)

  16. Connected vehicles and cybersecurity.

    Science.gov (United States)

    2016-01-01

    Connected vehicles are a next-generation technology in vehicles and in infrastructure that will make travel safer, cleaner, and more efficient. The advanced wireless technology enables vehicles to share and communicate information with each other and...

  17. Mentor Connections

    Science.gov (United States)

    Sciarappa, Kathleen

    2010-01-01

    Jargon associated with mentoring can be confusing. Is a new leader involved in induction, being mentored, or experiencing coaching? Induction is meant to familiarize a new employee with the details and scope of job responsibilities, while mentoring and coaching are directed at skill development. Elementary and secondary principals rate mentoring…

  18. Specification of a system for planning and analysis of independent generator connection impact on the electric distribution system; Especificacao de um sistema de planeamento e analise do impacto da conexao de geradores independentes no sistema electrico da distribuicao

    Energy Technology Data Exchange (ETDEWEB)

    Proenca, Luis Miguel; Matos, Manuel Antonio [Instituto de Engenharia de Sistemas e Computadores (INESC), Porto (Portugal); Campos, Manuel Luis Borges [Centro para a Excelencia na Distribuicao (CED), Sao Paulo, SP (Brazil)

    1999-07-01

    This paper describes a system for planning and analysis of the independent generator connection impact on the electric distribution system. This system is being developed under a contract signed between the Center for Excellency in the Distribution (CED), state of Sao Paulo - Brazil and the INESC, Porto - Portugal - energy unit.

  19. Irradiation of rainbow trout at early life stages results in trans-generational effects including the induction of a bystander effect in non-irradiated fish.

    Science.gov (United States)

    Smith, Richard W; Seymour, Colin B; Moccia, Richard D; Mothersill, Carmel E

    2016-02-01

    The bystander effect, a non-targeted effect (NTE) of radiation, which describes the response by non-irradiated organisms to signals emitted by irradiated organisms, has been documented in a number of fish species. However transgenerational effects of radiation (including NTE) have yet to be studied in fish. Therefore rainbow trout, which were irradiated as eggs at 48h after fertilisation, eyed eggs, yolk sac larvae or first feeders, were bred to generate a F1 generation and these F1 fish were bred to generate a F2 generation. F1 and F2 fish were swam with non-irradiated bystander fish. Media from explants of F1 eyed eggs, F1 one year old fish gill and F1 two year old fish gill and spleen samples, and F2 two year old gill and spleen samples, as well as from bystander eggs/fish, was used to treat a reporter cell line, which was then assayed for changes in cellular survival/growth. The results were complex and dependent on irradiation history, age (in the case of the F1 generation), and were tissue specific. For example, irradiation of one parent often resulted in effects not seen with irradiation of both parents. This suggests that, unlike mammals, in certain circumstances maternal and paternal irradiation may be equally important. This study also showed that trout can induce a bystander effect 2 generations after irradiation, which further emphasises the importance of the bystander effect in aquatic radiobiology. Given the complex community structure in aquatic ecosystems, these results may have significant implications for environmental radiological protection. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Irradiation of rainbow trout at early life stages results in trans-generational effects including the induction of a bystander effect in non-irradiated fish

    International Nuclear Information System (INIS)

    Smith, Richard W.; Seymour, Colin B.; Moccia, Richard D.; Mothersill, Carmel E.

    2016-01-01

    The bystander effect, a non-targeted effect (NTE) of radiation, which describes the response by non-irradiated organisms to signals emitted by irradiated organisms, has been documented in a number of fish species. However transgenerational effects of radiation (including NTE) have yet to be studied in fish. Therefore rainbow trout, which were irradiated as eggs at 48 h after fertilisation, eyed eggs, yolk sac larvae or first feeders, were bred to generate a F1 generation and these F1 fish were bred to generate a F2 generation. F1 and F2 fish were swam with non-irradiated bystander fish. Media from explants of F1 eyed eggs, F1 one year old fish gill and F1 two year old fish gill and spleen samples, and F2 two year old gill and spleen samples, as well as from bystander eggs/fish, was used to treat a reporter cell line, which was then assayed for changes in cellular survival/growth. The results were complex and dependent on irradiation history, age (in the case of the F1 generation), and were tissue specific. For example, irradiation of one parent often resulted in effects not seen with irradiation of both parents. This suggests that, unlike mammals, in certain circumstances maternal and paternal irradiation may be equally important. This study also showed that trout can induce a bystander effect 2 generations after irradiation, which further emphasises the importance of the bystander effect in aquatic radiobiology. Given the complex community structure in aquatic ecosystems, these results may have significant implications for environmental radiological protection. - Highlights: • We evaluated the transgenerational effect of early life irradiation in rainbow trout. • Trout irradiated as eggs, yolk sac larvae or first feeders were crossed. • A transgenerational effect was evident in two generations after irradiation. • F1 and F2 generation fish induced a bystander effect in non-irradiated fish. • The precise effects were tissue specific and dependent on

  1. Irradiation of rainbow trout at early life stages results in trans-generational effects including the induction of a bystander effect in non-irradiated fish

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Richard W., E-mail: rich.wilson.smith@gmail.com [Department of Animal Biosciences, University of Guelph, Guelph, Ontario (Canada); Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario (Canada); Seymour, Colin B. [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario (Canada); Moccia, Richard D. [Department of Animal Biosciences, University of Guelph, Guelph, Ontario (Canada); Mothersill, Carmel E. [Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, Ontario (Canada)

    2016-02-15

    The bystander effect, a non-targeted effect (NTE) of radiation, which describes the response by non-irradiated organisms to signals emitted by irradiated organisms, has been documented in a number of fish species. However transgenerational effects of radiation (including NTE) have yet to be studied in fish. Therefore rainbow trout, which were irradiated as eggs at 48 h after fertilisation, eyed eggs, yolk sac larvae or first feeders, were bred to generate a F1 generation and these F1 fish were bred to generate a F2 generation. F1 and F2 fish were swam with non-irradiated bystander fish. Media from explants of F1 eyed eggs, F1 one year old fish gill and F1 two year old fish gill and spleen samples, and F2 two year old gill and spleen samples, as well as from bystander eggs/fish, was used to treat a reporter cell line, which was then assayed for changes in cellular survival/growth. The results were complex and dependent on irradiation history, age (in the case of the F1 generation), and were tissue specific. For example, irradiation of one parent often resulted in effects not seen with irradiation of both parents. This suggests that, unlike mammals, in certain circumstances maternal and paternal irradiation may be equally important. This study also showed that trout can induce a bystander effect 2 generations after irradiation, which further emphasises the importance of the bystander effect in aquatic radiobiology. Given the complex community structure in aquatic ecosystems, these results may have significant implications for environmental radiological protection. - Highlights: • We evaluated the transgenerational effect of early life irradiation in rainbow trout. • Trout irradiated as eggs, yolk sac larvae or first feeders were crossed. • A transgenerational effect was evident in two generations after irradiation. • F1 and F2 generation fish induced a bystander effect in non-irradiated fish. • The precise effects were tissue specific and dependent on

  2. Connecting Grammaticalisation

    DEFF Research Database (Denmark)

    Nørgård-Sørensen, Jens; Heltoft, Lars; Schøsler, Lene

    morphological, topological and constructional paradigms often connect to form complex paradigms. The book introduces the concept of connecting grammaticalisation to describe the formation, restructuring and dismantling of such complex paradigms. Drawing primarily on data from Germanic, Romance and Slavic...

  3. Grid connection of active stall wind farms using a VSC based DC transmission system

    DEFF Research Database (Denmark)

    Iov, F.; Sørensen, Poul Ejnar; Hansen, A.D.

    2005-01-01

    Currently, there is an increasing trend to connect large MW wind farms to the transmission system. Requirements that focus on the influence of the farms on the grid stability and power quality, and on the control capabilities of wind farms have already been established. The main trends of modern...... wind turbines/farms are clearly the variable speed operation and a grid connection through a power electronic interface, especially using doubly fed induction generators. Using power electronics the control capabilities of these wind turbines/farms are extended and thus the grid requirements...... are fulfilled. However, the traditional squirrel-cage generators based wind turbines/wind farms directly connected to the grid have less control capabilities. These wind turbines/farms cannot regulate their production and contribute to power system stability. A DC transmission system for connection...

  4. Variable frequency operation of active stall wind farms using a dc connection to grid

    DEFF Research Database (Denmark)

    Iov, Florin; Blaabjerg, Frede; Sorensen, Poul

    2005-01-01

    Currently, there is an increasing trend to connect large MW wind farms to the transmISSIon system. Requirements that focus on the influence of the farms on the grid stability and power quality, and on the control capabilities of wind farms have already been established. The main trends of modern...... wind turbines/farms are clearly the variable speed operation and a grid connection through a power electronic interface, especially using doubly-fed induction generators. Using power electronics the control capabilities of these wind turbines/farms are extended and thus the grid requirements...... are fulfilled. However, the traditional squirrel-cage generators based wind turbines/wind farms directly connected to the grid have less control capabilities. These wind turbines/farms cannot regulate their production and contribute to power system stability. A DC transmission system for connection...

  5. Study of the non inductive current generation in Tore Supra and application to the operational scenario of a continuous tokamak; Etude de la generation de courant non inductive dans Tore Supra et application aux scenarios operationnels d`un tokamak continu

    Energy Technology Data Exchange (ETDEWEB)

    Kazarian-Vibert, F.

    1996-07-05

    Lower Hybrid Current Drive in tokamak plasmas allows to obtain continuous operations, which constitute a necessary step towards a definition of a thermonuclear fusion reactor. The objectives of this work is to define and study fully non inductive steady-state scenarios on Tore Supra. The current diffusion equation is solved to determined precisely the inductive and non inductive current density profiles and their influence on thee time evolution of a discharge. Then, a new operation mode is studied theoretically and experimentally. In this scenario, the transformer primary circuit voltage is controlled in such a way that the flux consumption vanishes. It allows to achieve full steady-state discharges in a fast and reproducible manner. A theoretical flux consumption scaling law during plasma current ramp-up assisted by Lower-Hybrid waves is presented and validated by experimental data, in view to minimized this consumption. The influence of a non monotonic current profile on the confinement and the transport of energy in the plasma is also clearly illustrated by experiments. (author). 138 refs., 16 figs., 1 tab.

  6. 78 FR 55684 - ConnectED Workshop

    Science.gov (United States)

    2013-09-11

    ... tools move everything from homework assignments to testing into the cloud. The workshop will explore possible strategies to connect virtually all of our students to next-generation broadband in a timely, cost-effective way. It will also share promising practices, from NTIA's Broadband Technology Opportunities...

  7. Non-linear, connectivity and threshold-dominated runoff-generation controls DOC and heavy metal export in a small peat catchment

    Science.gov (United States)

    Birkel, Christian; Broder, Tanja; Biester, Harald

    2017-04-01

    Peat soils act as important carbon sinks, but they also release large amounts of dissolved organic carbon (DOC) to the aquatic system. The DOC export is strongly tied to the export of soluble heavy metals. The accumulation of potentially toxic substances due to anthropogenic activities, and their natural export from peat soils to the aquatic system is an important health and environmental issue. However, limited knowledge exists as to how much of these substances are mobilized, how they are mobilized in terms of flow pathways and under which hydrometeorological conditions. In this study, we report from a combined experimental and modelling effort to provide greater process understanding from a small, lead (Pb) and arsenic (As) contaminated upland peat catchment in northwestern Germany. We developed a minimally parameterized, but process-based, coupled hydrology-biogeochemistry model applied to simulate detailed hydrometric and biogeochemical data. The model was based on an initial data mining analysis, in combination with regression relationships of discharge, DOC and element export. We assessed the internal model DOC-processing based on stream-DOC hysteresis patterns and 3-hourly time step groundwater level and soil DOC data (not used for calibration as an independent model test) for two consecutive summer periods in 2013 and 2014. We found that Pb and As mobilization can be efficiently predicted from DOC transport alone, but Pb showed a significant non-linear relationship with DOC, while As was linearly related to DOC. The relatively parsimonious model (nine calibrated parameters in total) showed the importance of non-linear and rapid near-surface runoff-generation mechanisms that caused around 60% of simulated DOC load. The total load was high even though these pathways were only activated during storm events on average 30% of the monitoring time - as also shown by the experimental data. Overall, the drier period 2013 resulted in increased nonlinearity, but

  8. d -Limonene sensitizes docetaxel-induced cytotoxicity in human prostate cancer cells: Generation of reactive oxygen species and induction of apoptosis

    Directory of Open Access Journals (Sweden)

    Rabi Thangaiyan

    2009-01-01

    Full Text Available Background: Clinical trials have shown that docetaxel combined with other novel agents can improve the survival of androgen-independent prostate cancer patients. d -Limonene, a non-nutrient dietary component, has been found to inhibit various cancer cell growths without toxicity. We sought to characterize whether a non-toxic dose of d -limonene may enhance tumor response to docetaxel in an in vitro model of metastatic prostate cancer. Materials and Methods: Human prostate carcinoma DU-145 and normal prostate epithelial PZ-HPV-7 cells were treated with various concentrations of d -limonene, docetaxel or a combination of both, and cell viability was determined by MTT assay. Intracellular reactive oxygen species (ROS, reduced glutathione (GSH and caspase activity were measured. Apoptosis and apoptosis-related proteins were studied by enzyme-linked immunosorbent assay and Western blotting, respectively. Results: d -Limonene and docetaxel in combination significantly enhanced the cytotoxicity to DU-145 cells than PZ-HPV-7 cells. Exposure of DU-145 cells to a combined d -limonene and docetaxel resulted in higher ROS generation, depletion of GSH, accompanied by increased caspase activity than docetaxel alone. It also triggered a series of effects involving cytochrome c , cleavages of caspase-9, 3 and poly (ADP-ribose polymerase, and a shift in Bad:Bcl-xL ratio in favor of apoptosis. Apoptotic effect was significantly blocked on pretreatment with N -acetylcystein, indicating that antitumor effect is initiated by ROS generation, and caspase cascades contribute to the cell death. Conclusion: Our results show, for the first time, that d -limonene enhanced the antitumor effect of docetaxel against prostate cancer cells without being toxic to normal prostate epithelial cells. The combined beneficial effect could be through the modulation of proteins involved in mitochondrial pathway of apoptosis. d -Limonene could be used as a potent non-toxic agent to

  9. Mega-ampere submicrosecond generator GIT-32

    International Nuclear Information System (INIS)

    Kovalchuk, B. M.; Kharlov, A. V.; Kiselev, V. N.; Kumpyak, E. V.; Zorin, V. B.; Chupin, V. V.; Morozov, A. V.

    2007-01-01

    The GIT-32 current generator was developed for experiments with current carrying pulsed plasma. The main parts of the generator are capacitor bank, multichannel multigap spark switches, low inductive current driving lines, and central load part. The generator consists of four identical sections, connected in parallel to one load. The capacitor bank is assembled from 32 IEK-100-0.17 (0.17 μF, 40 nH, 100 kV) capacitors, connected in parallel. It stores ∼18 kJ at 80 kV charging voltage. Each two capacitors are commuted to a load by a multigap spark switch with eight parallel channels. Switches operate in ambient air at atmospheric pressure. The GIT-32 generator was tested with 10, 15, and 20 nH inductive loads. At 10 nH load and 80 kV of charging voltage it provides 1 MA of current amplitude and 490 ns rise time with 0.8 Ω damping resistors in discharge circuit of each capacitor and 1.34 MA/530 ns without resistors. The net generator inductance without a load was optimized to be as low as 12 nH, which results in extremely low self-impedance of the generator (∼0.05 Ω). It ensures effective energy coupling with low impedance loads like Z pinch. The generator operates reliably without any adjustments in 40-80 kV range of charging voltage. Maximum jitter (relative to a triggering pulse) at 40 kV charging voltage is about 7 ns and lower at higher charging voltages. Operation and handling are very simple, because no oil and no purified gases are required for the generator. The GIT-32 generator has dimensions of 3200x3200x400 mm 3 and total weight of about 2500 kg, thus manifesting itself as a simple, robust, and cost effective apparatus

  10. New type of magnetohydrodynamic converters: induction devices

    International Nuclear Information System (INIS)

    Petit, J.-P.; Viton, Maurice.

    1977-01-01

    A new induction MHD accelerator, disc shaped, with controlled ionization, is presented. Associated with a light and powerful electric generator it could become a MHD aerodyne. Solutions for confining the plasma to the wall are indicated [fr

  11. Pulsed inductive HF laser

    Energy Technology Data Exchange (ETDEWEB)

    Razhev, A M; Kargapol' tsev, E S [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation); Churkin, D S; Demchuk, S V [Novosibirsk State University, Novosibirsk (Russian Federation)

    2016-03-31

    We report the results of experimentally investigated dependences of temporal, spectral and spatial characteristics of an inductive HF-laser generation on the pump conditions. Gas mixtures H{sub 2} – F{sub 2}(NF{sub 3} or SF6{sub 6}) and He(Ne) – H{sub 2} – F{sub 2}(NF{sub 3} or SF{sub 6}) were used as active media. The FWHM pulse duration reached 0.42 μs. This value corresponded to a pulsed power of 45 kW. For the first time, the emission spectrum of an inductive HF laser was investigated, which consisted of seven groups of bands with centres around the wavelengths of 2732, 2736, 2739, 2835, 2837, 2893 and 2913 nm. The cross section profile of the laser beam was a ring with a diameter of about 20 mm and width of about 5 mm. Parameters of laser operation in the repetitively pulsed regime were sufficiently stable. The amplitude instability of light pulses was no greater than 5% – 6%. (lasers)

  12. Economic evaluation of photovoltaic electric power generation connected to the grid in deregulated electric power markets; Avaliacao economica da geracao de energia eletrica fotovoltaica conectada a rede em mercados eletricos desregulados

    Energy Technology Data Exchange (ETDEWEB)

    Zumaran, David Richard Orosco

    2000-12-01

    This work presents an analysis of economic, tariff and regulating issues related to the introduction of Grid Connected Photovoltaic Systems in a deregulated electric market context; a case study for the peruvian electric market is realized. Based on the pricing system of the electric market, it is developed an economic assessment model that can be used by institutions interested in promoting this technology for generating electricity. (author)

  13. Making Connections

    Science.gov (United States)

    Pien, Cheng Lu; Dongsheng, Zhao

    2011-01-01

    Effective teaching includes enabling learners to make connections within mathematics. It is easy to accord with this statement, but how often is it a reality in the mathematics classroom? This article describes an approach in "connecting equivalent" fractions and whole number operations. The authors illustrate how a teacher can combine a common…

  14. The effectiveness of laser diode induction to Carica Papaya L. chlorophyll extract to be ROS generating in the photodynamic inactivation mechanisms for C.albicans biofilms

    International Nuclear Information System (INIS)

    Astuty, S Dewi; Baktir, A

    2017-01-01

    Research on the effectiveness of photo inactivation of C.albicans biofilms led by a-PDT system mediated by chlorophyll-diode-laser-induced was done. This research was done using in vitro technique in order to effectively determine chlorophyll extract of ROS-generated Carica Papaya L. using in situ technique. This technique induced laser diode on different dose and C. albicans with reduced degree. This research is a preliminary study in efforts to find anew sensitizer agent candidate made of chlorophyll extract and antifungal of Carica Papaya L. The effectiveness of eradication has been tested with MDA’s content and OD of biomass biofilms as well as analyzed using ANOVA and Tukey Test (α=0.05). The characteristic of chlorophyll extract of Carica Papaya L. has maximum absorptions on blue areas (λ max = 420 nm) and red areas (λ max = 670 nm). The MIC value of Carica Papaya L. ’s chlorophyll extract against C. albicans planktonic and biofilms cell is 63.8 μM and 31.9 μM respectively. The result shows that treatment using laser which was combined with chlorophyll extract is more effective than that with laser only or chlorophyll extract only. The treatment using laser combined with chlorophyll extract obtained more than 65% (α=0.05) (more than that of negative control) for P 2 L 1 group with OD 595 0.915. The MDA’s content showed that group of laser which was mediated with chlorophyll extract had larger values than group of laser or chlorophyll extract only. (paper)

  15. Project PAT (Pumps Working as Turbines)/IG (Induction Generators): a new concept for generation of electric power through micro scale hydroelectric power plants; Projeto BFT (Bombas Funcionado como Turbinas)/GI (Geradores de Inducao): um novo conceito para geracao de energia eletrica atraves de microcentrais hidreletricas

    Energy Technology Data Exchange (ETDEWEB)

    Viana, Augusto Nelson Carvalho [Universidade Federal de Itajuba (UNIFEI), Itajuba, MG (Brazil). Inst. de Recursos Naturais. Programa de Pos-graduacao em Engenharia da Energia; Medeiros, Daniel de Macedo; Ricardo, Mateus [Universidade Federal de Itajuba (UNIFEI), Itajuba, MG (Brazil). Inst. de Recursos Naturais], Emails: augusto@unifei.edu.br, macedo@unifei.edu.br, mathidr@yahoo.com.br

    2006-07-01

    The present work has as objective to present the main bases of 'PAT/IG Project', accomplished in Boa Esperanca Farm (Delfim Moreira - MG), by an accord between Itajuba's Federal University and Mines and Energy Ministry. In a moment that the look for sustainable development is the law in Brazil, low costs and environmental impact alternatives must be prioritized. By this way, the PAT/IG Project continuous the Viana's (1987) works, that developed all Brazilian theoretical bases for using Pumps Working as Turbine (PAT). Besides that, the application of induction motors operating as induction generators will be evaluated, as the velocity control system of the PAT/IG group will be developed. The existing Boa Esperanca Farm's micro power plant will be rebuild ed, to receive a new generating group formed for a PAT and a IG, that will be used as natural sized test workbench of Itajuba's Federal University. At the ending of the project, there will be enough subsidies to prove, in practice, the feasibility presented in laboratorial tests by PAT/IG groups as conventional turbines replacer in micro powerplants. (author)

  16. Project PAT (Pumps Working as Turbines)/IG (Induction Generators): a new concept for generation of electric power through micro scale hydroelectric power plants; Projeto BFT (Bombas Funcionado como Turbinas)/GI (Geradores de Inducao): um novo conceito para geracao de energia eletrica atraves de microcentrais hidreletricas

    Energy Technology Data Exchange (ETDEWEB)

    Viana, Augusto Nelson Carvalho [Universidade Federal de Itajuba (UNIFEI), Itajuba, MG (Brazil). Inst. de Recursos Naturais. Programa de Pos-graduacao em Engenharia da Energia; Medeiros, Daniel de Macedo; Ricardo, Mateus [Universidade Federal de Itajuba (UNIFEI), Itajuba, MG (Brazil). Inst. de Recursos Naturais], Emails: augusto@unifei.edu.br, macedo@unifei.edu.br, mathidr@yahoo.com.br

    2006-07-01

    The present work has as objective to present the main bases of 'PAT/IG Project', accomplished in Boa Esperanca Farm (Delfim Moreira - MG), by an accord between Itajuba's Federal University and Mines and Energy Ministry. In a moment that the look for sustainable development is the law in Brazil, low costs and environmental impact alternatives must be prioritized. By this way, the PAT/IG Project continuous the Viana's (1987) works, that developed all Brazilian theoretical bases for using Pumps Working as Turbine (PAT). Besides that, the application of induction motors operating as induction generators will be evaluated, as the velocity control system of the PAT/IG group will be developed. The existing Boa Esperanca Farm's micro power plant will be rebuild ed, to receive a new generating group formed for a PAT and a IG, that will be used as natural sized test workbench of Itajuba's Federal University. At the ending of the project, there will be enough subsidies to prove, in practice, the feasibility presented in laboratorial tests by PAT/IG groups as conventional turbines replacer in micro powerplants. (author)

  17. About Connections

    Directory of Open Access Journals (Sweden)

    Kathleen S Rockland

    2015-05-01

    Full Text Available Despite the attention attracted by connectomics, one can lose sight of the very real questions concerning What are connections? In the neuroimaging community, structural connectivity is ground truth and underlying constraint on functional or effective connectivity. It is referenced to underlying anatomy; but, as increasingly remarked, there is a large gap between the wealth of human brain mapping and the relatively scant data on actual anatomical connectivity. Moreover, connections have typically been discussed as pairwise, point x projecting to point y (or: to points y and z, or more recently, in graph theoretical terms, as nodes or regions and the interconnecting edges. This is a convenient shorthand, but tends not to capture the richness and nuance of basic anatomical properties as identified in the classic tradition of tracer studies. The present short review accordingly revisits connectional weights, heterogeneity, reciprocity, topography, and hierarchical organization, drawing on concrete examples. The emphasis is on presynaptic long-distance connections, motivated by the intention to probe current assumptions and promote discussions about further progress and synthesis.

  18. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  19. Isotope dilution inductively coupled plasma quadrupole mass spectrometry in connection with a chromatographic separation for ultra trace determinations of platinum group elements (Pt, Pd, Ru, Ir) in environmental samples.

    Science.gov (United States)

    Müller, M; Heumann, K G

    2000-09-01

    An isotope dilution inductively coupled plasma quadrupole mass spectrometric (ID-ICP-QMS) method was developed for the simultaneous determination of the platinum group elements Pt, Pd, Ru, and Ir in environmental samples. Spike solutions, enriched with the isotopes 194Pt, 108Pd, 99Ru, and 191Ir, were used for the isotope dilution step. Interfering elements were eliminated by chromatographic separation using an anion-exchange resin. Samples were dissolved with aqua regia in a high pressure asher. Additional dissolution of possible silicate portions by hydrofluoric acid was usually not necessary. Detection limits of 0.15 ng x g(-1), 0.075 ng x g(-1), and 0.015 ng x g(-1) were achieved for Pt, Pd, Ru, and Ir, respectively, using sample weights of only 0.2 g. The reliability of the ID-ICP-QMS method was demonstrated by analyzing a Canadian geological reference material and by participating in an interlaboratory study for the determination of platinum and palladium in a homogenized road dust sample. Surface soil, sampled at different distances from a highway, showed concentrations in the range of 0.1-87 ng x g(-1). An exponential decrease of the platinum and palladium concentration with increasing distance and a small anthropogenic contribution to the natural background concentration of ruthenium and iridium was found in these samples.

  20. Resonant Inductive Power Transfer for Noncontact Launcher-Missile Interface

    Science.gov (United States)

    2016-08-01

    implementation of a wireless power transfer system based on the concept of non-radiating inductive coupling. 14. SUBJECT TERMS Resonant Inductive Coupling... Wireless Power Transfer 15. NUMBER OF PAGES 18 16. PRICE CODE 17. SECURITY CLASSIFICATION OF REPORT UNCLASSIFIED 18. SECURITY...2 In contrast to the ideal transformer, wireless inductive power transfer assumes that the coils are no longer physically connected by an iron core

  1. Numerical simulation of induction heating thick-walled tubes

    Directory of Open Access Journals (Sweden)

    Lenhard Richard

    2018-01-01

    Full Text Available In the paper is shown the connection of two toolboxes in an Ansys Workbench solution for induction heating. In Ansys Workbench, Maxwell electromagnetism programs and Fluent have been linked. In Maxwell, a simulation of electromagnetic induction was performed, where data on the magnetic field distribution in the heated material was obtained and then transformed into the Fluent program in which the induction heating simulation was performed.

  2. Inductive Reasoning and Writing

    Science.gov (United States)

    Rooks, Clay; Boyd, Robert

    2003-01-01

    Induction, properly understood, is not merely a game, nor is it a gimmick, nor is it an artificial way of explaining an element of reasoning. Proper understanding of inductive reasoning--and the various types of reasoning that the authors term inductive--enables the student to evaluate critically other people's writing and enhances the composition…

  3. Internet Connectivity

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Internet Connectivity. BSNL, SIFY, HCL in Guwahati; only BSNL elsewhere in NE (local player in Shillong). Service poor; All vendors lease BW from BSNL.

  4. Mathematics Connection

    African Journals Online (AJOL)

    MATHEMATICS CONNECTION aims at providing a forum topromote the development of Mathematics Education in Ghana. Articles that seekto enhance the teaching and/or learning of mathematics at all levels of theeducational system are welcome.

  5. HR Connect

    Data.gov (United States)

    US Agency for International Development — HR Connect is the USAID HR personnel system which allows HR professionals to process HR actions related to employee's personal and position information. This system...

  6. Induction Acceleration of a Single RF Bunch in the KEK PS

    CERN Document Server

    Takayama, Ken; Arakida, Yoshio; Horioka, Kazuhiko; Igarashi, Susumu; Iwashita, Taiki; Kawasaki, Atsushi; Kishiro, Junichi; Kono, Tadaaki; Koseki, Kunio; Nakamura, Eiji; Sakuda, Makoto; Sato, Hikaru; Shiho, Makoto; Shimosaki, Yoshito; Shirakata, Masashi; Sueno, Tsuyoshi; Tokuchi, Akira; Torikai, Kota; Toyama, Takeshi; Wake, Masayoshi; Watanabe, Masao; Yamane, Isao

    2005-01-01

    A single bunch trapped in an RF bucket was accelerated by induction devices from 500 MeV to 8GeV beyond transition energy in the KEK-PS. This is the first demonstration of induction acceleration in a high energy circular ring. The acceleration was confirmed by measuring a temporal evolution of the RF phase through an entire acceleration.* Key devices in an induction acceleration system are an induction accelerating cavity capable of generating an induced voltage of 2kV/cell, a pulse modulator to drive the cavity (switching driver), and a DSP system to control gate signals for switching. Their remarkable characteristics are its repetition ratio of about 1MHz and duty factor of 50%. All devices have been newly developed at KEK so as to meet this requirement. The pulse modulator employing MOSFETs as switching elements is connected with the accelerating cavity through a long transmission cable in order to avoid a high-dose irradiation in the accelerator tunnel. The induction system has been running beyond more th...

  7. Power Quality of Grid-Connected Wind Turbines with DFIG and Their Interaction with the Grid

    DEFF Research Database (Denmark)

    Sun, Tao

    quality issues of grid-connected wind turbines and the interaction between wind turbines and the grid. The specific goal of the research has been to investigate flicker emission and mitigation of grid-connected wind turbines with doubly fed induction generators (DFIG) during continuous operation...... measures are proposed to mitigate the flicker levels produced by grid-connected wind turbines with DFIG, respectively by wind turbine output reactive power control and using STATCOM. Simulation results demonstrate that these two measures are effective for flicker mitigation regardless of mean wind speed....... To evaluate the flicker levels produced by grid-connected wind turbines with DFIG, a flickermeter model is developed according to the IEC standard IEC 61000-4-15, which simulates the response of the lamp-eye-brain chain and provides on-line statistical analysis ofthe flicker signal and the final results...

  8. The law of electromagnetic induction

    Directory of Open Access Journals (Sweden)

    V.J. Kutkovetskyy

    2014-09-01

    Full Text Available Mathematical models of the electromagnetic induction law which do not take into account Faraday’s restrictions are not in full accordance with the physical phenomenon and so they are not laws. Their incomplete correspondence with real devices results in such "paradoxes" as unlimited magnetic field of unipolar generators, infinite sizes of inductors for DC and AC machines modeled, and so on.

  9. Performance Analysis of a Four-Switch Three-Phase Grid-Side Converter with Modulation Simplification in a Doubly-Fed Induction Generator-Based Wind Turbine (DFIG-WT with Different External Disturbances

    Directory of Open Access Journals (Sweden)

    Kai Ni

    2017-05-01

    Full Text Available This paper investigates the performance of a fault-tolerant four-switch three-phase (FSTP grid-side converter (GSC in a doubly-fed induction generator-based wind turbine (DFIG-WT. The space vector pulse width modulation (SVPWM technique is simplified and unified duty ratios are used for controlling the FSTP GSC. Steady DC-bus voltage, sinusoidal three-phase grid currents and unity power factor are obtained. In addition, the balance of capacitor voltages is accomplished based on the analysis of current flows at the midpoint of DC bus in different operational modes. Besides, external disturbances such as fluctuating wind speed and grid voltage sag are considered to test its fault-tolerant ability. Furthermore, the effects of fluctuating wind speed on the performance of DFIG-WT system are explained according to an approximate expression of the turbine torque. The performance of the proposed FSTP GSC is simulated in Matlab/Simulink 2016a based on a detailed 1.5 MW DFIG-WT Simulink model. Experiments are carried out on a 2 kW platform by using a discrete signal processor (DSP TMS320F28335 controller to validate the reliability of DFIG-WT for the cases with step change of the stator active power and grid voltage sag, respectively.

  10. Simultaneous Robust Coordinated Damping Control of Power System Stabilizers (PSSs, Static Var Compensator (SVC and Doubly-Fed Induction Generator Power Oscillation Dampers (DFIG PODs in Multimachine Power Systems

    Directory of Open Access Journals (Sweden)

    Jian Zuo

    2017-04-01

    Full Text Available The potential of utilizing doubly-fed induction generator (DFIG-based wind farms to improve power system damping performance and to enhance small signal stability has been proposed by many researchers. However, the simultaneous coordinated tuning of a DFIG power oscillation damper (POD with other damping controllers is rarely involved. A simultaneous robust coordinated multiple damping controller design strategy for a power system incorporating power system stabilizer (PSS, static var compensator (SVC POD and DFIG POD is presented in this paper. This coordinated damping control design strategy is addressed as an eigenvalue-based optimization problem to increase the damping ratios of oscillation modes. Both local and inter-area electromechanical oscillation modes are intended in the optimization design process. Wide-area phasor measurement unit (PMU signals, selected by the joint modal controllability/ observability index, are utilized as SVC and DFIG POD feedback modulation signals to suppress inter-area oscillation modes. The robustness of the proposed coordinated design strategy is achieved by simultaneously considering multiple power flow situations and operating conditions. The recently proposed Grey Wolf optimizer (GWO algorithm is adopted to efficiently optimize the parameter values of multiple damping controllers. The feasibility and effectiveness of the proposed coordinated design strategy are demonstrated through frequency-domain eigenvalue analysis and nonlinear time-domain simulation studies in two modified benchmark test systems. Moreover, the dynamic response simulation results also validate the robustness of the recommended coordinated multiple damping controllers under various system operating conditions.

  11. Induction machine handbook

    CERN Document Server

    Boldea, Ion

    2002-01-01

    Often called the workhorse of industry, the advent of power electronics and advances in digital control are transforming the induction motor into the racehorse of industrial motion control. Now, the classic texts on induction machines are nearly three decades old, while more recent books on electric motors lack the necessary depth and detail on induction machines.The Induction Machine Handbook fills industry's long-standing need for a comprehensive treatise embracing the many intricate facets of induction machine analysis and design. Moving gradually from simple to complex and from standard to

  12. Efficient generation of volatile cadmium species using Ti(III) and Ti(IV) and application to determination of cadmium by cold vapor generation inductively coupled plasma mass spectrometry (CVG-ICP-MS)†

    Science.gov (United States)

    Arslan, Zikri; Yilmaz, Vedat; Rose, LaKeysha

    2015-01-01

    In this study, a highly efficient chemical vapor generation (CVG) approach is reported for determination of cadmium (Cd). Titanium (III) and titanium (IV) were investigated for the first time as catalytic additives along with thiourea, L-cysteine and potassium cyanide (KCN) for generation of volatile Cd species. Both Ti(III) and Ti(IV) provided the highest enhancement with KCN. The improvement with thiourea was marginal (ca. 2-fold), while L-cysteine enhanced signal slightly only with Ti(III) in H2SO4. Optimum CVG conditions were 4% (v/v) HCl + 0.03 M Ti(III) + 0.16 M KCN and 2% (v/v) HNO3 + 0.03 M Ti(IV) + 0.16 M KCN with a 3% (m/v) NaBH4 solution. The sensitivity was improved about 40-fold with Ti(III) and 35-fold with Ti(IV). A limit of detection (LOD) of 3.2 ng L−1 was achieved with Ti(III) by CVG-ICP-MS. The LOD with Ti(IV) was 6.4 ng L−1 which was limited by the blank signals in Ti(IV) solution. Experimental evidence indicated that Ti(III) and Ti(IV) enhanced Cd vapor generation catalytically; for best efficiency mixing prior to reaction with NaBH4 was critical. The method was highly robust against the effects of transition metal ions. No significant suppression was observed in the presence of Co(II), Cr(III), Cu(II), Fe(III), Mn(II), Ni(II) and Zn(II) up to 1.0 μg mL−1. Among the hydride forming elements, no interference was observed from As(III) and Se(IV) at 0.5 μg mL−1 level. The depressive effects from Pb(II) and Sb(III) were not significant at 0.1 μg mL−1 while those from Bi(III) and Sn(II) were marginal. The procedures were validated with determination of Cd by CVG-ICP-MS in a number certified reference materials, including Nearshore seawater (CASS-4), Bone ash (SRM 1400), Dogfish liver (DOLT-4), Mussel tissue (SRM 2976) and Domestic Sludge (SRM 2781). PMID:26251554

  13. Modeling and Control of VSC based DC Connection for Active Stall Wind Farms to Grid

    DEFF Research Database (Denmark)

    Iov, Florin; Sorensen, Poul; Hansen, Anca-Daniela

    2005-01-01

    Currently, there is an increasing trend to connect large MW wind farms to the transmission system. Therefore the power system becomes more vulnerable and dependent on the wind energy production. At the same time requirements that focus on the influence of the farms on the grid stability and power...... quality, and on the control capabilities of wind farms have already been established. The main trends of modem wind turbines/farms are clearly the variable speed operation and a grid connection through a power electronic interface, especially using doubly-fed induction generators. Using power electronics...... the control capabilities of these wind turbines/farms are extended and thus the grid requirements are fulfilled. However, the traditional squirrel-cage generators based wind turbines/wind farms directly connected to the grid does not have such control capabilities. They produce maximum possible power...

  14. Modelling and Control of VSC based DC Connection for Active Stall Wind Farms to Grid

    DEFF Research Database (Denmark)

    Iov, Florin; Sørensen, Poul; Hansen, Anca Daniela

    2006-01-01

    Currently, there is an increasing trend to connect large MW wind farms to the transmission system. Therefore the power system becomes more vulnerable and dependent on the wind energy production. At the same time requirements that focus on the influence of the farms on the grid stability and power...... quality, and on the control capabilities of wind farms have already been established. The main trends of modern wind turbines/farms are clearly the variable speed operation and a grid connection through a power electronic interface, especially using doubly-fed induction generators. Using power electronics...... the control capabilities of these wind turbines/farms are extended and thus the grid requirements are fulfilled.  However, the traditional squirrel-cage generators based wind turbines/wind farms directly connected to the grid does not have such control capabilities. They produce maximum possible power...

  15. Modelling, Analysis and Control of DC-connected Wind Farms to Grid

    DEFF Research Database (Denmark)

    Iov, Florin; Sørensen, Poul; Hansen, Anca Daniela

    2006-01-01

    wind turbines/farms are clearly the variable speed operation and a grid connection through a power electronic interface, especially using doubly-fed induction generators. Using power electronics the control capabilities of these wind turbines/farms are extended and thus the grid requirements...... are fulfilled.  However, the traditional squirrel-cage generators based wind turbines/wind farms directly connected to the grid have less control capabilities. These wind turbines/farms cannot regulate their production and contribute to power system stability. A DC transmission system for connection...... of the active stall wind farms to the grid can provide these features and also maximize the produced power especially at low wind speeds by using variable voltage/frequency for the wind farm. The focus in this paper is in studying the variable speed operation for the active stall wind farms using a voltage...

  16. Comb-like optical transmission spectra generated from one-dimensional two-segment-connected two-material waveguide networks optimized by genetic algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yu [MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631 (China); Yang, Xiangbo, E-mail: xbyang@scnu.edu.cn [MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631 (China); School of Physical Education and Sports Science, South China Normal University, Guangzhou 510006 (China); Lu, Jian; Zhang, Guogang [MOE Key Laboratory of Laser Life Science and Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631 (China); Liu, Chengyi Timon [School of Physical Education and Sports Science, South China Normal University, Guangzhou 510006 (China)

    2014-03-01

    In this Letter, a one-dimensional (1D) two-segment-connected two-material waveguide network (TSCTMWN) is designed to produce comb-like frequency passbands, where each waveguide segment is composed of normal and anomalous dispersion materials and the length ratio of sub-waveguide segments is optimized by genetic algorithm (GA). It is found that 66 comb-like frequency passbands are created in the second frequency unit, maximal relative width difference of which is less than 2×10{sup −5}. It may be useful for the designing of dense wavelength division multiplexings (DWDMs) and multi-channel filters, etc., and provide new applications for GA.

  17. Establishing Connectivity

    DEFF Research Database (Denmark)

    Kjær, Poul F.

    Global law settings are characterised by a structural pre-eminence of connectivity norms, a type of norm which differs from coherency or possibility norms. The centrality of connectivity norms emerges from the function of global law, which is to increase the probability of transfers of condensed ...... and human rights can be understood as serving a constitutionalising function aimed at stabilising and facilitating connectivity. This allows for an understanding of colonialism and contemporary global governance as functional, but not as normative, equivalents.......Global law settings are characterised by a structural pre-eminence of connectivity norms, a type of norm which differs from coherency or possibility norms. The centrality of connectivity norms emerges from the function of global law, which is to increase the probability of transfers of condensed...... social components, such as economic capital and products, religious doctrines and scientific knowledge, from one legally structured context to another within world society. This was the case from colonialism and colonial law to contemporary global supply chains and human rights. Both colonial law...

  18. Rating Requirements of the UPQC to Integrate the FSIG Type Wind Generation to the Grid

    OpenAIRE

    Jayanti, N.; Basu, Malabika; Conlon, Michael; Gaughan, Kevin

    2009-01-01

    The ability of wind generation to remain connected to the grid in the event of system faults and dynamic reactive power compensation are two aspects of grid integration, which have received particular attention. The wind driven, fixed-speed induction generator (FSIG) on its own fails to fulfil these requirements of grid integration. The application of a unified power quality conditioner (UPQC) to overcome the grid integration problems of the FSIG is investigated. The role of the UPQC in enhan...

  19. Experience in connecting the power generating units of thermal power plants to automatic secondary frequency regulation within the united power system of Russia

    International Nuclear Information System (INIS)

    Zhukov, A. V.; Komarov, A. N.; Safronov, A. N.; Barsukov, I. V.

    2009-01-01

    The principles of central control of the power generating units of thermal power plants by automatic secondary frequency and active power overcurrent regulation systems, and the algorithms for interactions between automatic power control systems for the power production units in thermal power plants and centralized systems for automatic frequency and power regulation, are discussed. The order of switching the power generating units of thermal power plants over to control by a centralized system for automatic frequency and power regulation and by the Central Coordinating System for automatic frequency and power regulation is presented. The results of full-scale system tests of the control of power generating units of the Kirishskaya, Stavropol, and Perm GRES (State Regional Electric Power Plants) by the Central Coordinating System for automatic frequency and power regulation at the United Power System of Russia on September 23-25, 2008, are reported.

  20. Connected Traveler

    Energy Technology Data Exchange (ETDEWEB)

    2016-06-01

    The Connected Traveler framework seeks to boost the energy efficiency of personal travel and the overall transportation system by maximizing the accuracy of predicted traveler behavior in response to real-time feedback and incentives. It is anticipated that this approach will establish a feedback loop that 'learns' traveler preferences and customizes incentives to meet or exceed energy efficiency targets by empowering individual travelers with information needed to make energy-efficient choices and reducing the complexity required to validate transportation system energy savings. This handout provides an overview of NREL's Connected Traveler project, including graphics, milestones, and contact information.

  1. Flow injection electrochemical hydride generation inductively coupled plasma time-of-flight mass spectrometry for the simultaneous determination of hydride forming elements and its application to the analysis of fresh water samples

    International Nuclear Information System (INIS)

    Bings, Nicolas H.; Stefanka, Zsolt; Mallada, Sergio Rodriguez

    2003-01-01

    A flow injection (FI) method was developed using electrochemical hydride generation (EcHG) as a sample introduction system, coupled to an inductively coupled plasma time-of-flight mass spectrometer (ICP-TOFMS) for rapid and simultaneous determination of six elements forming hydrides (As, Bi, Ge, Hg, Sb and Se). A novel low volume electrolysis cell, especially suited for FI experiments was designed and the conditions for simultaneous electrochemical hydride generation (EcHG; electrolyte concentrations and flow rates, electrolysis voltage and current) as well as the ICP-TOFMS operational parameters (carrier gas flow rate, modulation pulse width (MPW)) for the simultaneous determination of 12 isotopes were optimized. The compromise operation parameters of the electrolysis were found to be 1.4 and 3 ml min -1 for the anolyte and catholyte flow rates, respectively, using 2 M sulphuric acid. An optimum electrolysis current of 0.7 A (16 V) and an argon carrier gas flow rate of 0.91 l min -1 were chosen. A modulation pulse width of 5 μs, which influences the sensitivity through the amount of ions being collected by the MS per single analytical cycle, provided optimum results for the detection of transient signals. The achieved detection limits were compared with those obtained by using FI in combination with conventional nebulization (FI-ICP-TOFMS); values for chemical hydride generation (FI-CHG-ICP-TOFMS) were taken from the literature. By using a 200 μl sample loop absolute detection limits (3σ) in the range of 10-160 pg for As, Bi, Ge, Hg, Sb and 1.1 ng for Se and a precision of 4-8% for seven replicate injections of 20-100 ng ml -1 multielemental sample solutions were achieved. The analysis of a standard reference material (SRM) 1643d (NIST, 'Trace Elements in Water') showed good agreement with the certified values for As and Sb. Se showed a drastic difference, which is probably due to the presence of hydride-inactive Se species in the sample. Recoveries better than

  2. Understanding the effects of potassium ferricyanide on lead hydride formation in tetrahydroborate system and its application for determination of lead in milk using hydride generation inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Deng, Biyang; Xu, Xiangshu; Xiao, Yan; Zhu, Pingchuan; Wang, Yingzi

    2015-01-01

    Highlights: • Proposed a novel explanation for plumbane generation. • Expounded the role of K 3 Fe(CN) 6 in plumbane generation. • Clarified the controversial aspects in the mechanism of K 3 Fe(CN) 6 enhancement. • Used X-ray diffractometry to analyze the intermediates. • Developed a method to analyze lead in milk using K 3 Fe(CN) 6 and K 4 Fe(CN) 6 as new additives. - Absract: To understand the formation of plumbane in the Pb II -NaBH 4 -K 3 Fe(CN) 6 system, the intermediate products produced in the reaction of lead(II) and NaBH 4 in the presence of K 3 Fe(CN) 6 were studied. The produced plumbane and elemental lead were measured through continuous flow hydride generation (HG)-inductively coupled plasma optical emission spectrometry (ICP OES) and X-ray diffraction spectrometry techniques, respectively. Based on the experimental results, the explanations can be depicted in the following steps: (1) plumbane and black lead sediment (black Pb) are formed in the reaction of lead(II) and NaBH 4 ; (2) the black Pb is oxidized by K 3 Fe(CN) 6 to form Pb 2 [Fe(CN) 6 ], which further reacts with NaBH 4 to form more plumbane and black Pb; and (3) another round starts in which the produced black Pb from the step 2 is then oxidized continuously by K 3 Fe(CN) 6 to form more Pb 2 [Fe(CN) 6 ] complex, which would produce more plumbane. In short, the black Pb and Pb 2 [Fe(CN) 6 ] complex are the key intermediate products for the formation of plumbane in the Pb II -NaBH 4 -K 3 Fe(CN) 6 system. Based on the enhancement effect of potassium ferricyanide and potassium ferrocyanide, a method was developed to analyze lead in milk with HG-ICP OES technique. The detection limit of the method was observed as 0.081 μg L −1 . The linearity range of lead was found between 0.3 and 50,000 μg L −1 with correlation coefficient of 0.9993. The recovery of lead was determined as 97.6% (n = 5) for adding 10 μg L −1 lead into the milk sample

  3. Massless particles, electromagnetism, and Rieffel induction

    International Nuclear Information System (INIS)

    Landsman, N.P.; Wiedemann, U.A.

    1994-06-01

    The connection between space-time covariant representations (obtained by inducing from the Lorentz group) and irreducible unitary representations (induced from Wigner's little group) of the Poincare groups is re-examined in the massless case. In the situation relevant to physics, it is found that these are related by Marsden-Weinstein reduction with respect to a gauge group. An analogous phenomenon is observed for classical massless relativistic particles. This symplectic reduction procedure can be ('second') quantized using a generalization of the Rieffel induction technique in operator algebra theory, which is carried through in detail for electromagnetism. Starting from the so-called Fermi representation of the field algebra generated by the free abelian gauge field, we construct a new ('rigged') sesquilinear form on the representation space, which is positive semi-definite, and given in terms of a Gaussian weak distribution (promeasure) on the gauge group (taken to be a Hilbert Lie group). This eventually constructs the algebra of observables of quantum electromagnetism (directly in its vacuum representation) as a representation of the so-called algebra of weak observables induced by the trivial representation of the gauge group. (orig.)

  4. Making connections

    NARCIS (Netherlands)

    Marion Duimel

    2007-01-01

    Original title: Verbinding maken; senioren en internet. More and more older people are finding their way to the Internet. Many people aged over 50 who have only recently gone online say that a new world has opened up for them. By connecting to the Internet they have the feeling that they

  5. CMS Connect

    Science.gov (United States)

    Balcas, J.; Bockelman, B.; Gardner, R., Jr.; Hurtado Anampa, K.; Jayatilaka, B.; Aftab Khan, F.; Lannon, K.; Larson, K.; Letts, J.; Marra Da Silva, J.; Mascheroni, M.; Mason, D.; Perez-Calero Yzquierdo, A.; Tiradani, A.

    2017-10-01

    The CMS experiment collects and analyzes large amounts of data coming from high energy particle collisions produced by the Large Hadron Collider (LHC) at CERN. This involves a huge amount of real and simulated data processing that needs to be handled in batch-oriented platforms. The CMS Global Pool of computing resources provide +100K dedicated CPU cores and another 50K to 100K CPU cores from opportunistic resources for these kind of tasks and even though production and event processing analysis workflows are already managed by existing tools, there is still a lack of support to submit final stage condor-like analysis jobs familiar to Tier-3 or local Computing Facilities users into these distributed resources in an integrated (with other CMS services) and friendly way. CMS Connect is a set of computing tools and services designed to augment existing services in the CMS Physics community focusing on these kind of condor analysis jobs. It is based on the CI-Connect platform developed by the Open Science Grid and uses the CMS GlideInWMS infrastructure to transparently plug CMS global grid resources into a virtual pool accessed via a single submission machine. This paper describes the specific developments and deployment of CMS Connect beyond the CI-Connect platform in order to integrate the service with CMS specific needs, including specific Site submission, accounting of jobs and automated reporting to standard CMS monitoring resources in an effortless way to their users.

  6. Best connected rectangular arrangements

    Directory of Open Access Journals (Sweden)

    Krishnendra Shekhawat

    2016-03-01

    Full Text Available It can be found quite often in the literature that many well-known architects have employed either the golden rectangle or the Fibonacci rectangle in their works. On contrary, it is rare to find any specific reason for using them so often. Recently, Shekhawat (2015 proved that the golden rectangle and the Fibonacci rectangle are one of the best connected rectangular arrangements and this may be one of the reasons for their high presence in architectural designs. In this work we present an algorithm that generates n-4 best connected rectangular arrangements so that the proposed solutions can be further used by architects for their designs.

  7. STEAMakers- a global initiative to connect STEM career professionals with the public to inspire the next generation and nurture a creative approach to science, technology, maths & engineering

    Science.gov (United States)

    Shaw, Niamh; Sorkhabi, Elburz; Gasquez, Oriol; Yajima, Saho

    2016-04-01

    STEAMakers is a global initiative founded by Niamh Shaw, Elburz Sorkhabi, Oriol Gasquez & Saho Yajima, four alumni of The International Space University's Space Studies Programme 2015 who each shared a vision to inspire the next generation to embrace science, technology, engineering & maths (STEM) in new ways, by embedding the Arts within STEM, putting the 'A' in STEAM. STEAMakers invited STEM professionals around the world to join their community, providing training and a suite of STEAM events, specially designed to encourage students to perceive science, technology, engineering & maths as a set of tools with which to create, design, troubleshoot, innovate, and imagine. The ultimate goal of STEAMakers is to grow this community and create a global culture of non-linear learning among the next generation, to nurture within them a new multidisciplinary mindset and incubate new forms of innovation and thought leadership required for the future through the power of inspiration and creativity.

  8. Biomass and bio-fuel based poly-generation for off-grid and grid-connected operation. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    2012-07-01

    The overall objective of this project was to design and build a combined heat and power plant based on an updraft gasifier and a 35 kW electrical output Stirling engine and further to test the flexibility of the plant with regards to fuel and application. In the project a containerized combined heat and power plant including a 200 kW updraft gasifier and a 35 kW electrical output Stirling engine was designed, the specified components were procured, the plant was installed in the three containers and the plant was erected at Amagerforbraendingen ready for the COP15 in November 2009. The potential of operating the Stirling engine in island-mode (without grid connection) was investigated by mathematical modelling. Using an absorption cooling plant connected to the Stirling CHP plant was also investigated. A technical feasibility study was undertaken and it was concluded that from the two available technologies (water/LiBr and Ammonia/water) the appropriate choice is depending on the required cooling temperature. Test runs focussed on investigating the fuel flexibility of two different configurations of Stirling engine CHP plants were carried out - respectively the updraft gasifier plant (the containerized plant and the DTU plant) and the pyrolysis plant (the plant situated at Barritskov). In order to perform these test runs a stable operation is required. On both the containerized plant and the pyrolysis plant this proved to be more challenging than expected and therefore the number of fuels tested was limited to willow chips at the containerized plant and dry wood residues, wood pellets and straw pellets on the pyrolysis plant. For all tested fuels it was possible to operate the plants, however different issues mainly related to the quality of the fuels were encountered. And so it can be concluded that the quality of the fuel is critical for the operation of both the updraft gasifier plant and the pyrolysis plant. A comprehensive desktop evaluation of the feasibility

  9. 大型并网光伏发电系统方案设计探讨%Discussion on the Design of Large-scale Grid-connected Photovoltaic Power Generation System

    Institute of Scientific and Technical Information of China (English)

    马春兰

    2015-01-01

    As a non-exhausted and clean energy source, the solar energy attracts worldwide attention nowadays.A grid-connected photovoltaic power generation project located in the Ruoqiang Industry Park is presented, including the design of photovoltaic power generation system and the optimization scheme, which could be a useful reference for similar pro-jects.%太阳能作为一种永不枯竭、无污染的清洁能源,已经越来越受到科技工作者们的重视,各国也在努力开发和利用太阳能。以若羌产业园区光伏并网项目为依托,介绍了光伏发电站的发电系统方案设计及其优化设计,可供类似工程参考。

  10. Gendered Connections

    DEFF Research Database (Denmark)

    Jensen, Steffen Bo

    2009-01-01

    This article explores the gendered nature of urban politics in Cape Town by focusing on a group of female, township politicians. Employing the Deleuzian concept of `wild connectivity', it argues that these politically entrepreneurial women were able to negotiate a highly volatile urban landscape...... by drawing on and operationalizing violent, male networks — from struggle activists' networks, to vigilante groups and gangs, to the police. The fact that they were women helped them to tap into and exploit these networks. At the same time, they were restricted by their sex, as their ability to navigate...... space also drew on quite traditional notions of female respectability. Furthermore, the article argues, the form of wild connectivity to an extent was a function of the political transition, which destabilized formal structures of gendered authority. It remains a question whether this form...

  11. Alkali and chlorine in biomass - a problem in connection with power generation. Alkali och klor i biomassa - ett problem vid elgenerering

    Energy Technology Data Exchange (ETDEWEB)

    Gaerdenaes, S

    1991-06-04

    The literature survey gives a summary of the macronutrients and the variations in different biomass. Especially alkali is discussed. The work gives an account of difficult biomass fuels which will rather be used in hot water boilers than in gas turbines of power generation. The amount of alkali and chlorine increases from hardwood < softwood < salix < straw from Phalaris arundineral (harvested during summer). The range of variation was 10-25 between the assortments. The fraction division is the most important factor for the variation. Alkaline content also depend on age, soil fertility and storage methods. Seasonal aspects and local depositions are less important. However, great care should be taken with fuel from coastal areas because of chlorine depositions. Gasification of biomass to produce gas for combined cycle operation poses special problems. The alkali content of logging residues have to be cleaned up to approximately 99 % in the example. When the process gas is originated from straw or salix the separation have to be even more efficient. The method used for the separation could be based on wet or dry technic hotgas cleanup has not yet been tested in large scale but seems to be a promising method to attain high degree of separation and power efficiency. Difficulties of power generation make straw fuels less interesting. The content of alkali and chlorine can be considerably decreased by changing the way of fertilization and cultivation period. If everything turns out well, this would give a complementary for gasification or steam generation. To the greates part this fuels will however be used in pure heat production. (author).

  12. Active and Reactive Power Control Strategy for Grid-Connected Six-Phase Generator by Using Multi-Modular Matrix Converters

    Directory of Open Access Journals (Sweden)

    David Caballero

    2016-12-01

    Full Text Available This paper proposes an active and reactive power control strategy based on predictive control approaches applied to gridconnected renewable energy systems. To accomplish this a multi-modular matrix converter topologies are used in combination with a simple but efficient grid synchronization strategy. The theoretical performance analysis is performed considering a six-phase wind energy generator system interconnected with the grid. Results based on a MATLAB/Simulink simulation environment are discussed and the most relevant characteristics of the proposed control technique are highlighted considering the total harmonic distortion and the mean squared error as a parameters of performance.

  13. The potential impacts of grid-connected distributed generation and how to address them: A review of technical and non-technical factors

    International Nuclear Information System (INIS)

    Passey, Robert; Spooner, Ted; MacGill, Iain; Watt, Muriel; Syngellakis, Katerina

    2011-01-01

    Distributed generation is being deployed at increasing levels of penetration on electricity grids worldwide. It can have positive impacts on the network, but also negative impacts if integration is not properly managed. This is especially true of photovoltaics, in part because it's output fluctuates significantly and in part because it is being rapidly deployed in many countries. Potential positive impacts on grid operation can include reduced network flows and hence reduced losses and voltage drops. Potential negative impacts at high penetrations include voltage fluctuations, voltage rise and reverse power flow, power fluctuations, power factor changes, frequency regulation and harmonics, unintentional islanding, fault currents and grounding issues. This paper firstly reviews each of these impacts in detail, along with the current technical approaches available to address them. The second section of this paper discusses key non-technical factors, such as appropriate policies and institutional frameworks, which are essential to effectively coordinate the development and deployment of the different technical solutions most appropriate for particular jurisdictions. These frameworks will be different for different jurisdictions, and so no single approach will be appropriate worldwide. - Highlights: → Distributed generation can have both positive and negative impacts on networks. → Technical solutions to address these negative impacts are discussed. → The required appropriate policies and institutional frameworks are discussed.

  14. Urofollitropin and ovulation induction

    NARCIS (Netherlands)

    van Wely, Madelon; Yding Andersen, Claus; Bayram, Neriman; van der Veen, Fulco

    2005-01-01

    Anovulation is a common cause of female infertility. Treatment for women with anovulation is aimed at induction of ovulation. Ovulation induction with follicle-stimulating hormone (FSH) is indicated in women with WHO type II anovulation in whom treatment with clomifene citrate (clomifene) has

  15. Inductance loop and partial

    CERN Document Server

    Paul, Clayton R

    2010-01-01

    "Inductance is an unprecedented text, thoroughly discussing "loop" inductance as well as the increasingly important "partial" inductance. These concepts and their proper calculation are crucial in designing modern high-speed digital systems. World-renowned leader in electromagnetics Clayton Paul provides the knowledge and tools necessary to understand and calculate inductance." "With the present and increasing emphasis on high-speed digital systems and high-frequency analog systems, it is imperative that system designers develop an intimate understanding of the concepts and methods in this book. Inductance is a much-needed textbook designed for senior and graduate-level engineering students, as well as a hands-on guide for working engineers and professionals engaged in the design of high-speed digital and high-frequency analog systems."--Jacket.

  16. Resolution 369/012. It authorize to Vientos de Pastoral S.A. to generate a wind power electricity source by 150.0 MW generating station section, and their connection to National interconnected system

    International Nuclear Information System (INIS)

    2012-01-01

    It has been allowed the wind power generation electricity energy source as a the primary electricity source. This project was presented by the Vientos de Pastoral S.A company according to the opinion of the National Energy Regulatory Unit and the Energy and Water Services in relation with the requirements of the current rule

  17. A Straightforward Convergence Method for ICCG Simulation of Multiloop and Time-Stepping FE Model of Synchronous Generators with Simultaneous AC and Rectified DC Connections

    Directory of Open Access Journals (Sweden)

    Shanming Wang

    2015-01-01

    Full Text Available Now electric machines integrate with power electronics to form inseparable systems in lots of applications for high performance. For such systems, two kinds of nonlinearities, the magnetic nonlinearity of iron core and the circuit nonlinearity caused by power electronics devices, coexist at the same time, which makes simulation time-consuming. In this paper, the multiloop model combined with FE model of AC-DC synchronous generators, as one example of electric machine with power electronics system, is set up. FE method is applied for magnetic nonlinearity and variable-step variable-topology simulation method is applied for circuit nonlinearity. In order to improve the simulation speed, the incomplete Cholesky conjugate gradient (ICCG method is used to solve the state equation. However, when power electronics device switches off, the convergence difficulty occurs. So a straightforward approach to achieve convergence of simulation is proposed. At last, the simulation results are compared with the experiments.

  18. Tandem organic light-emitting diodes with KBH4 doped 9,10-bis(3-(pyridin-3-yl)phenyl) anthracene connected to the charge generation layer.

    Science.gov (United States)

    Duan, Lian; Tsuboi, Taiju; Qiu, Yong; Li, Yanrui; Zhang, Guohui

    2012-06-18

    Tandem organic light emitting diodes (OLEDs) are ideal for lighting applications due to their low working current density at high brightness. In this work, we have studied an efficient electron transporting layer of KBH(4) doped 9,10-bis(3-(pyridin-3-yl)phenyl)anthracene (DPyPA) which is located adjacent to charge generation layer of MoO(3)/NPB. The excellent transporting property of the DPyPA:KBH(4) layer helps the tandem OLED to achieve a lower voltage than the tandem device with the widely used tris-(8-hydroxyquinoline)aluminum:Li. For the tandem white OLED with a fluorescent blue unit and a phosphorescent yellow unit, we've achieved a high current efficiency of 75 cd/A, which can be further improved to 120 cd/A by attaching a diffuser layer.

  19. About Eddy Currents in Induction Melting Processes

    Directory of Open Access Journals (Sweden)

    Gafiţa Nicolae-Bogdan

    2008-05-01

    Full Text Available In this paper we present a method forcomputing the eddy currents in induction meltingprocesses for non-ferrous alloys. We take intoconsideration the situation when only the crucible ismoving, inside the coils. This fact makes differentialcomputation methods to be hard to apply, because isnecessary to generate a new mesh and a new systemmatrix for every for every new position of the cruciblerelated to the coils. Integral methods cancel thisdrawback because the mesh is generated only for thedomains with eddy currents. For integral methods, themesh and the inductance matrix remain unchangedduring the movement of the crucible; only the free termsof the equation system will change.

  20. Cosmic Connections

    CERN Document Server

    Ellis, Jonathan Richard

    2003-01-01

    A National Research Council study on connecting quarks with the cosmos has recently posed a number of the more important open questions at the interface between particle physics and cosmology. These questions include the nature of dark matter and dark energy, how the Universe began, modifications to gravity, the effects of neutrinos on the Universe, how cosmic accelerators work, and whether there are new states of matter at high density and pressure. These questions are discussed in the context of the talks presented at this Summer Institute.