WorldWideScience

Sample records for indoor-outdoor no2 levels

  1. Indoor NO{sub 2} levels in homes with different sources of air pollution - traffic, gas-use, smoking

    Energy Technology Data Exchange (ETDEWEB)

    Rudnai, P.; Farkas, I.; Bacskai, J.; Sarkany, E. [Bela Johan National Inst. of Hygiene, Budapest (Hungary); Somogyi, J. [Public Health Inst. of County Gyor-Moson-Sopron, Gyor (Hungary)

    1993-12-31

    Outdoor and indoor levels of NO{sub 2} in and around the homes of 300 children living in different parts of two Hungarian towns, Gyor and Sopron, were measured. Possible sources of NO{sub 2} pollution were assessed by questionnaires. NO{sub 2} levels in homes without any further known sources (like gas use for cooking and/or heating and smoking) varied according to the outdoor levels mainly depending on traffic density. Gas heaters had the strongest influence on the indoor NO{sub 2} levels measured in the children`s bedrooms while gas use for cooking and smoking proved to be the second and third most important source of indoor NO{sub 2} pollution. Different outdoor and indoor NO{sub 2} sources should be taken into account when planning the heating and ventilation systems of new buildings. (author)

  2. Indoor and outdoor concentrations of RSP, NO2 and selected volatile organic compounds at 32 shoe stalls located near busy roadways in Seoul, Korea

    International Nuclear Information System (INIS)

    Bae, Hyunjoo; Chung, Moonho; Yang, Wonho

    2004-01-01

    It is suspected that persons who work in indoor environments near busy roadways are exposed to elevated levels of air pollutants during working hours. This study evaluated the potential exposure and source contribution associated with traffic-related air pollution for workers (polishers and repairmen) in shoe stalls from each of 32 districts during working hours in Seoul, Korea. The shoe stalls have been located at very close distances to the busy roadways. In this study, shoe stall workers could be exposed to high levels of respirable suspended particulate (RSP), nitrogen dioxide (NO 2 ) and volatile organic compounds (VOCs) from outdoor sources such as traffic exhaust, as well as indoor sources in the shoe stalls such as dust on the shoes, portable gas ranges, organic solvents, adhesives and shoe polish. Compounds of particular note included indoor mean concentrations of benzene, toluene, m/p-xylene and o-xylene were 0.732, 6.777, 4.080 and 1.302 mg/m 3 , respectively, in all shoe stalls. Mean indoor/outdoor ratios for toluene and m/p-xylene concentrations were 54.52 and 20.84, respectively. The contribution of vehicle exhaust emissions to indoor air quality of shoe stalls was identified by means of correlating the relationships between simultaneously measured air pollutant concentrations indoors and outdoors. Unlike RSP and NO 2 , indoor VOCs concentrations of shoe stalls mainly originated from indoor sources vs. outdoor sources

  3. Indoor PM1, PM2.5, PM10 and outdoor PM2.5 concentrations in primary schools in Sari, Iran.

    Science.gov (United States)

    Mohammadyan, Mahmoud; Shabankhani, Bijan

    2013-09-01

    This study was carried out to determine the distribution of particles in classrooms in primary schools located in the centre of the city of Sari, Iran and identify the relationship between indoor classroom particle levels and outdoor PM2.5 concentrations. Outdoor PM2.5 and indoor PM1, PM2.5, and PM10 were monitored using a real-time Micro Dust Pro monitor and a GRIMM monitor, respectively. Both monitors were calibrated by gravimetric method using filters. The Kolmogorov-Smirnov test showed that all indoor and outdoor data fitted normal distribution. Mean indoor PM1, PM2.5, PM10 and outdoor PM2.5 concentrations for all of the classrooms were 17.6 μg m(-3), 46.6 μg m(-3), 400.9 μg m(-3), and 36.9 μg m(-3), respectively. The highest levels of indoor and outdoor PM2.5 concentrations were measured at the Shahed Boys School (69.1 μg m(-3) and 115.8 μg m(-3), respectively). The Kazemi school had the lowest levels of indoor and outdoor PM2.5 (29.1 μg m(-3) and 15.5 μg m(-3), respectively). In schools located near both main and small roads, the association between indoor fine particle (PM2.5 and PM1) and outdoor PM2.5 levels was stronger than that between indoor PM10 and outdoor PM2.5 levels. Mean indoor PM2.5 and PM10 and outdoor PM2.5 were higher than the standards for PM2.5 and PM10, and there was a good correlation between indoor and outdoor fine particle concentrations.

  4. Activity pattern and personal exposure to nitrogen dioxide in indoor and outdoor microenvironments.

    Science.gov (United States)

    Kornartit, C; Sokhi, R S; Burton, M A; Ravindra, Khaiwal

    2010-01-01

    People are exposed to air pollution from a range of indoor and outdoor sources. Concentrations of nitrogen dioxide (NO(2)), which is hazardous to health, can be significant in both types of environments. This paper reports on the measurement and analysis of indoor and outdoor NO(2) concentrations and their comparison with measured personal exposure in various microenvironments during winter and summer seasons. Furthermore, the relationship between NO(2) personal exposure in various microenvironments and including activities patterns were also studied. Personal, indoor microenvironments and outdoor measurements of NO(2) levels were conducted using Palmes tubes for 60 subjects. The results showed significant differences in indoor and outdoor NO(2) concentrations in winter but not for summer. In winter, indoor NO(2) concentrations were found to be strongly correlated with personal exposure levels. NO(2) concentration in houses using a gas cooker was higher in all rooms than those with an electric cooker during the winter campaign, whereas there was no significant difference noticed in summer. The average NO(2) levels in kitchens with a gas cooker were twice as high as those with an electric cooker, with no significant difference in the summer period. A time-weighted average personal exposure was calculated and compared with measured personal exposures in various indoor microenvironments (e.g. front doors, bedroom, living room and kitchen); including non-smokers, passive smokers and smoker. The estimated results were closely correlated, but showed some underestimation of the measured personal exposures to NO(2) concentrations. Interestingly, for our particular study higher NO(2) personal exposure levels were found during summer (14.0+/-1.5) than winter (9.5+/-2.4).

  5. Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows.

    Science.gov (United States)

    Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Röösli, Martin; Brink, Mark; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc

    2018-01-18

    Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios-of open, tilted, and closed windows-were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor-indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor-indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows.

  6. Modeling indoor air pollution of outdoor origin in homes of SAPALDIA subjects in Switzerland.

    Science.gov (United States)

    Meier, Reto; Schindler, Christian; Eeftens, Marloes; Aguilera, Inmaculada; Ducret-Stich, Regina E; Ineichen, Alex; Davey, Mark; Phuleria, Harish C; Probst-Hensch, Nicole; Tsai, Ming-Yi; Künzli, Nino

    2015-09-01

    Given the shrinking spatial contrasts in outdoor air pollution in Switzerland and the trends toward tightly insulated buildings, the Swiss Cohort Study on Air Pollution and Lung and Heart Diseases in Adults (SAPALDIA) needs to understand to what extent outdoor air pollution remains a determinant for residential indoor exposure. The objectives of this paper are to identify determining factors for indoor air pollution concentrations of particulate matter (PM), ultrafine particles in the size range from 15 to 300nm, black smoke measured as light absorbance of PM (PMabsorbance) and nitrogen dioxide (NO2) and to develop predictive indoor models for SAPALDIA. Multivariable regression models were developed based on indoor and outdoor measurements among homes of selected SAPALDIA participants in three urban (Basel, Geneva, Lugano) and one rural region (Wald ZH) in Switzerland, various home characteristics and reported indoor sources such as cooking. Outdoor levels of air pollutants were important predictors for indoor air pollutants, except for the coarse particle fraction. The fractions of outdoor concentrations infiltrating indoors were between 30% and 66%, the highest one was observed for PMabsorbance. A modifying effect of open windows was found for NO2 and the ultrafine particle number concentration. Cooking was associated with increased particle and NO2 levels. This study shows that outdoor air pollution remains an important determinant of residential indoor air pollution in Switzerland. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Personal exposures to NO2 in the EXPOLIS-study: relation to residential indoor, outdoor and workplace concentrations in Basel, Helsinki and Prague

    International Nuclear Information System (INIS)

    Kousa, A.; Rotko, T.; Alm, S.; Monn, C.

    2001-01-01

    Personal exposures, residential indoor, outdoor and workplace levels of nitrogen dioxide (NO 2 ) were measured for 262 urban adult (25-55 years) participants in three EXPOLIS centres (Basel, Switzerland; Helsinki, Finland; and Prague, Czech Republic) using passive samplers for 48-h sampling periods during 1996-1997. The average residential outdoor and indoor NO 2 levels were lowest in Helsinki (24 ± 12 and 18 ± 11 μgm -3 , respectively), highest in Prague (61 ± 20 and 43 ± 23μgm -3 ), with Basel in between (36 ± 13 and 27± 13μgm -3 ). Average workplace NO 2 levels, however, were highest in Basel (36 ± 24μgm -3 ), lowest in Helsinki (27 ± 15μgm -3 ), with Prague in between (30 ± 18μgm -3 ). A time-weighted microenvironmental exposure model explained 74% of the personal exposure variation in all centre and in average 88% of the exposures. Log-linear regression models, using residential outdoor measurements (fixed site monitoring) combined with residential and work characteristics (i.e. work location, using gas appliances and keeping windows open), explained 48% (37%) of the personal NO 2 exposure variation. Regression models based on ambient fixed site concentrations alone explained only 11-19% of personal NO 2 exposure variation. Thus, ambient fixed site monitoring alone was a poor predictor for personal NO 2 exposure variation, but adding personal questionnaire information can significantly improve the predicting power. (Author)

  8. A comprehensive air quality investigation at an aquatic centre: Indoor/outdoor comparisons.

    Science.gov (United States)

    Tolis, Evangelos I; Panaras, Giorgos; Bartzis, John G

    2018-06-01

    Air quality and comfort parameters in a naturally ventilated aquatic centre were studied in relation to the outdoor pollution levels. Simultaneous measurements of PM 2.5, as well as of volatile organic compounds, were carried out for the indoor and outdoor environment of the aquatic centre. The chemical analysis of ionic species and trace elements associated with particulate matter was also performed. In addition, automated analyzer for NO 2 and O 3 was used in order to record the indoor and outdoor levels of these pollutants. Analysis of diurnal variation of the pollutants' concentration was applied to the collected data, allowing the identification of potential variation on the sources affecting the indoor air quality. PM 2.5 concentration was almost two times higher indoors than outdoors with average values of 13.96 and 6.78 μg/m 3 , respectively. Concerning the ion fraction of PM 2.5, SO 4 2- and Ca 2+ were the ions with higher concentration indoors with values of 1.06 and 0.93 μg/m 3 , respectively, while the percentage of Cl - to the PM 2.5 fraction of the indoor atmosphere (9%) was too high than outdoor ones (1%). These results showed that indoor air of swimming pool concerning PM 2.5 and ionic species is mainly affected by the chlorination process along with the comfort conditions (high relative humidity) created during the operation of the facility. The common volatile organic compound concentrations at indoor air are generally in higher levels, compared to the outdoor air with p,m-xylene and toluene to be the substances with the higher concentration for indoor and outdoor area, respectively (7.80 and 1.57 μg/m 3 ); nevertheless, values were rather low compared with the findings of other studies. Also, they clearly demonstrate a diurnal variation as a result of poor ventilation during night. As it was expected, chloroform showed the highest concentration compared to the other volatile organic compounds with values ranging from 3.35 to 135.89 μg/m 3

  9. Reducing indoor residential exposures to outdoor pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Matson, Nance E.

    2003-07-01

    The basic strategy for providing indoor air quality in residences is to dilute indoor sources with outdoor air. This strategy assumes that the outdoor air does not have pollutants at harmful levels or that the outdoor air is, at least, less polluted than the indoor air. When this is not the case, different strategies need to be employed to ensure adequate air quality in the indoor environment. These strategies include ventilation systems, filtration and other measures. These strategies can be used for several types of outdoor pollution, including smog, particulates and toxic air pollutants. This report reviews the impacts that typical outdoor air pollutants can have on the indoor environment and provides design and operational guidance for mitigating them. Poor quality air cannot be used for diluting indoor contaminants, but more generally it can become an indoor contaminant itself. This paper discusses strategies that use the building as protection against potentially hazardous outdoor pollutants, including widespread pollutants, accidental events, and potential attacks.

  10. Indoor and Outdoor Levels and Sources of Submicron Particles (PM1) at Homes in Edmonton, Canada.

    Science.gov (United States)

    Bari, Md Aynul; Kindzierski, Warren B; Wallace, Lance A; Wheeler, Amanda J; MacNeill, Morgan; Héroux, Marie-Ève

    2015-06-02

    Exposure to submicron particles (PM1) is of interest due to their possible chronic and acute health effects. Seven consecutive 24-h PM1 samples were collected during winter and summer 2010 in a total of 74 nonsmoking homes in Edmonton, Canada. Median winter concentrations of PM1 were 2.2 μg/m(3) (interquartile range, IQR = 0.8-6.1 μg/m(3)) and 3.3 μg/m(3) (IQR = 1.5-6.9 μg/m(3)) for indoors and outdoors, respectively. In the summer, indoor (median 4.4 μg/m(3), IQR = 2.4-8.6 μg/m(3)) and outdoor (median 4.3 μg/m(3), IQR = 2.6-7.4 μg/m(3)) levels were similar. Positive matrix factorization (PMF) was applied to identify and apportion indoor and outdoor sources of elements in PM1 mass. Nine sources contributing to both indoor and outdoor PM1 concentrations were identified including secondary sulfate, soil, biomass smoke and environmental tobacco smoke (ETS), traffic, settled and mixed dust, coal combustion, road salt/road dust, and urban mixture. Three additional indoor sources were identified i.e., carpet dust, copper-rich, and silver-rich. Secondary sulfate, soil, biomass smoke and ETS contributed more than 70% (indoors: 0.29 μg/m(3), outdoors: 0.39 μg/m(3)) of measured elemental mass in PM1. These findings can aid understanding of relationships between submicron particles and health outcomes for indoor/outdoor sources.

  11. Indoor-outdoor nitric oxide and nitrogen dioxide concentrations at three sites in Riyadh, Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, D.R. (D.R. Rowe Engineering Services, Inc., Bowling Green, KY (United States)); Al-Dhowalia, K.H.; Mansour, M.E. (King Saud Univ., Riyadh (Saudi Arabia))

    1991-08-01

    The objective of this study was to evaluate the nitric oxide and nitrogen oxide concentrations indoors and outdoors at three sites in Riyadh, Saudi Arabia. Results show that the outdoor and indoor concentrations for NO were at least 270 and 16 times the reported average worldwide NO concentrations, respectively. The NO(sub 2) concentrations were about 14 times reported outdoor worldwide levels; however, NO(sub 2) concentrations indoors were generally below those reported in the literature. The data presented, in combination with information presented in previous articles, will provide a valuable background database for use in dispersion models to determine the effect of the Kuwaiti oil well fires on the air quality of Riyadh.

  12. Comparison of background levels of culturable fungal spore concentrations in indoor and outdoor air in southeastern Austria

    Science.gov (United States)

    Haas, D.; Habib, J.; Luxner, J.; Galler, H.; Zarfel, G.; Schlacher, R.; Friedl, H.; Reinthaler, F. F.

    2014-12-01

    Background concentrations of airborne fungi are indispensable criteria for an assessment of fungal concentrations indoors and in the ambient air. The goal of this study was to define the natural background values of culturable fungal spore concentrations as reference values for the assessment of moldy buildings. The concentrations of culturable fungi were determined outdoors as well as indoors in 185 dwellings without visible mold, obvious moisture problems or musty odor. Samples were collected using the MAS-100® microbiological air sampler. The study shows a characteristic seasonal influence on the background levels of Cladosporium, Penicillium and Aspergillus. Cladosporium sp. had a strong outdoor presence, whereas Aspergillus sp. and Penicillium sp. were typical indoor fungi. For the region of Styria, the median outdoor concentrations are between 100 and 940 cfu/m³ for culturable xerophilic fungi in the course of the year. Indoors, median background levels are between 180 and 420 cfu/m³ for xerophilic fungi. The I/O ratios of the airborne fungal spore concentrations were between 0.2 and 2.0. For the assessment of indoor and outdoor air samples the dominant genera Cladosporium, Penicillium and Aspergillus should receive special consideration.

  13. Concentration levels of radon in air, indoors and outdoors in houses of Mexico City

    International Nuclear Information System (INIS)

    Pena Garcia, P.

    1992-01-01

    Concentration levels of radon in air, indoors and outdoors have been obtained in houses from Mexico City, with the purpose of relating them with the local environment. Measurements were performed both outdoors and indoors in 60 unifamiliar houses. Track detectors, LR-115, Type II, were used in several detection arrangements during four recording periods with times of exposure of three months each, with the purpose of analyzing the fluctuations due to seasonal changes. Data were obtained about the construction materials were the detection systems were located in order to establish a correlation of radon levels with the climatic parameters and the construction materials. The results of radon concentrations both indoors or outdoors were lower than the international recommendations (148 Bq/m 3 ) (Author)

  14. Differences between Outdoor and Indoor Sound Levels for Open, Tilted, and Closed Windows

    Science.gov (United States)

    Locher, Barbara; Piquerez, André; Habermacher, Manuel; Ragettli, Martina; Cajochen, Christian; Vienneau, Danielle; Foraster, Maria; Müller, Uwe; Wunderli, Jean Marc

    2018-01-01

    Noise exposure prediction models for health effect studies normally estimate free field exposure levels outside. However, to assess the noise exposure inside dwellings, an estimate of indoor sound levels is necessary. To date, little field data is available about the difference between indoor and outdoor noise levels and factors affecting the damping of outside noise. This is a major cause of uncertainty in indoor noise exposure prediction and may lead to exposure misclassification in health assessments. This study aims to determine sound level differences between the indoors and the outdoors for different window positions and how this sound damping is related to building characteristics. For this purpose, measurements were carried out at home in a sample of 102 Swiss residents exposed to road traffic noise. Sound pressure level recordings were performed outdoors and indoors, in the living room and in the bedroom. Three scenarios—of open, tilted, and closed windows—were recorded for three minutes each. For each situation, data on additional parameters such as the orientation towards the source, floor, and room, as well as sound insulation characteristics were collected. On that basis, linear regression models were established. The median outdoor–indoor sound level differences were of 10 dB(A) for open, 16 dB(A) for tilted, and 28 dB(A) for closed windows. For open and tilted windows, the most relevant parameters affecting the outdoor–indoor differences were the position of the window, the type and volume of the room, and the age of the building. For closed windows, the relevant parameters were the sound level outside, the material of the window frame, the existence of window gaskets, and the number of windows. PMID:29346318

  15. Indoor and outdoor PM10 levels at schools located near mine dumps in Gauteng and North West Provinces, South Africa

    Directory of Open Access Journals (Sweden)

    Vusumuzi Nkosi

    2017-01-01

    Full Text Available Abstract Background Few studies in South Africa have investigated the exposure of asthmatic learners to indoor and outdoor air pollution at schools. This study compared outdoor PM10 and SO2 exposure levels in exposed (1–2 km from gold mine dumps and unexposed schools (5 km or more from gold mine dumps. It also examined exposure of asthmatic children to indoor respirable dust at exposed and unexposed schools. Methods The study was conducted between 1 and 31 October 2012 in five schools from exposed and five from unexposed communities. Outdoor PM10 and SO2 levels were measured for 8-h at each school. Ten asthmatic learners were randomly selected from each school for 8-h personal respirable dust sampling during school hours. Results The level of outdoor PM10 for exposed was 16.42 vs. 11.47 mg.m−3 for the unexposed communities (p < 0.001. The outdoor SO2 for exposed was 0.02 ppb vs. 0.01 ppb for unexposed communities (p < 0.001. Indoor respirable dust in the classroom differed significantly between exposed (0.17 mg.m−3 vs. unexposed (0.01 mg.m−3 children with asthma at each school (p < 0.001. Conclusion The significant differences between exposed and unexposed schools could reveal a serious potential health hazard for school children, although they were within the South African Air Quality Standards’ set by the Department of Environmental Affairs. The indoor respirable dust levels in exposed schools could have an impact on children with asthma, as they were significantly higher than the unexposed schools, although there are no published standards for environmental exposure for children with asthma.

  16. Research on Integration of Indoor and Outdoor Positioning in Professional Athletic Training

    Directory of Open Access Journals (Sweden)

    Yongqing Liu

    2018-02-01

    Full Text Available GNSS is widely used in professional athletic training as an outdoor location based services, and the indoor positioning technology has gradually flourished in the gymnasium. To keep up with the demand for athletic training in indoor and outdoor environment, integration of indoor and outdoor positioning technology can achieve a seamless indoor/outdoor position solution. The proposed method uses GPS/BEIDOU with IMU-MEMS technology for outdoor positioning and UWB with IMU-MEMS technology for indoor positioning to provide high precision positioning services. The experimental results show that the proposed method can achieve meter level position accuracy in outdoor environment and centimeter level position accuracy in indoor environment, it can provide precise and real-time positioning service for effective athletic training aid.

  17. Indoor versus outdoor time in preschoolers at child care.

    Science.gov (United States)

    Tandon, Pooja S; Saelens, Brian E; Zhou, Chuan; Kerr, Jacqueline; Christakis, Dimitri A

    2013-01-01

    Being outdoors may have health benefits including being more physically active. Understanding the relationship between outdoor time and health is hampered by the difficulty of measuring outdoor time. To examine the accuracy and validity of light-sensor and GPS methods for quantifying outdoor time among those aged 3-5 years at child care. A total of 45 children (mean age 4.5 years, 64% boys) from five child care centers wore portable accelerometers with built-in light sensors and a separate GPS device around their waists during child care, providing 80,648 episodes (15 seconds each) for analysis. Direct observation (gold standard) of children being outdoors versus indoors was conducted for 2 days at each center. GPS signal-to-noise ratios, processed through the Personal Activity and Location Measurement System were used to define indoor versus outdoor locations. Receiver operating characteristic (ROC) analyses were used to determine thresholds for defining being indoors versus outdoors. Data were collected in Fall 2011, analyzed in 2012. Mean observed outdoor time was 63 [±44; range: 18-152] minutes/day. Mean light-sensor levels were significantly higher outdoors. The area under the ROC curve for location based on light sensor for all weather conditions was 0.82 (range: 0.70 on partly cloudy days to 0.97 on sunny days); for GPS, it was 0.89. The light sensor had a sensitivity of 74% and specificity of 86%. GPS had a sensitivity of 82% and specificity of 88%. A light sensor and a GPS device both distinguish indoor from outdoor time for preschoolers with moderate to high levels of accuracy. These devices can increase the feasibility and lower the cost of measuring outdoor time in studies of preschool children. Copyright © 2013 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  18. Microenvironmental air and soil monitoring of contaminants: An evaluation of indoor and outdoor levels in Chihuahua City

    Science.gov (United States)

    Delgado-Rios, Marcos

    Like most of the cities around the world Chihuahua City suffers atmospheric and soil pollution. This is a problem that requires immediate attention from both public authorities and the scientific community. Although it is known that high levels of heavy metals are present in the airborne particulate matter, soil and dust in many urban regions, the information about personal exposure to these pollutants in Chihuahua City is nonexistent. This study focuses on the analysis and characterization of lead and arsenic in the airborne and soil particulate matter present in the interiors of households and their surrounding outdoor environments in the southern part of Chihuahua City. The sampling area chosen for this study was located in the southern part of Chihuahua City. An atmospheric sampling point selected by the Centro de Investigacion en Materiales Avanzados (CIMAV) was selected as a geographical center, with a 2 km radius forming the sampling area. The households selected for analyses were located on Lombardo Toledano Street, a high-traffic street. The main objectives of this study were to establish the maximum exposure level in outdoor and indoor environments for particulate matter less than 10 mum (PM 10), Pb, and As, to determine the background level of Chihuahua City for these same elements, to determine the isotopic ratios of Pb206 and Pb207 in the indoor and outdoor atmospheric samples, and to verify if the source of the pollution is from anthropogenic and/or natural sources. Additionally, a comparison of the analytical data from X-ray fluorescence (XRF) versus the analytical data from inductively coupled plasma with optical emission spectroscopy (ICP-OES) was conducted. The comparison of these techniques was based on sample preparation, speed of analysis, and accuracy of results. In the case of sample preparation, two extraction techniques were performed for a comparison of the extraction/leaching of Pb and As from the samples. These microwave

  19. Indoor/outdoor elemental concentration relationships at a nursery school

    International Nuclear Information System (INIS)

    Lannefors, H.; Hansson, H.C.

    1981-01-01

    Indoor and outdoor concentrations of lead and bromine have been measured at a nursery school, using streaker samplers with 2.4 h resolution. The observed variations in concentration were well-correlated with traffic intensity variations. In addition to their closely related time-variation curves, the bromine to lead ratios pointed to the emissions from leaded gasoline-powered vehicles as the main source of these elements both in and outdoors. Time-variation patterns on weekdays and during weekends indicated that the lead and bromine containing particles entered the nursery school mainly by leaking. Only a minor fraction seemed to be brought in and resuspended by the staff and children. The indoor concentrations of the elements studied were about 5 times lower than the outdoor levels thus considerably reducing the indoor exposure. (orig.)

  20. Airborne particle-bound brominated flame retardants: Levels, size distribution and indoor-outdoor exchange.

    Science.gov (United States)

    Zhu, Yue-Shan; Yang, Wan-Dong; Li, Xiu-Wen; Ni, Hong-Gang; Zeng, Hui

    2018-02-01

    The quality of indoor environments has a significant impact on public health. Usually, an indoor environment is treated as a static box, in which physicochemical reactions of indoor air contaminants are negligible. This results in conservative estimates for primary indoor air pollutant concentrations, while also ignoring secondary pollutants. Thus, understanding the relationship between indoor and outdoor particles and particle-bound pollutants is of great significance. For this reason, we collected simultaneous indoor and outdoor measurements of the size distribution of airborne brominated flame retardant (BFR) congeners. The time-dependent concentrations of indoor particles and particle-bound BFRs were then estimated with the mass balance model, accounting for the outdoor concentration, indoor source strength, infiltration, penetration, deposition and indoor resuspension. Based on qualitative observation, the size distributions of ΣPBDE and ΣHBCD were characterized by bimodal peaks. According to our results, particle-bound BDE209 and γ-HBCD underwent degradation. Regardless of the surface adsorption capability of particles and the physicochemical properties of the target compounds, the concentration of BFRs in particles of different size fractions seemed to be governed by the particle distribution. Based on our estimations, for airborne particles and particle-bound BFRs, a window-open ventilated room only takes a quarter of the time to reach an equilibrium between the concentration of pollutants inside and outside compared to a closed room. Unfortunately, indoor pollutants and outdoor pollutants always exist simultaneously, which poses a window-open-or-closed dilemma to achieve proper ventilation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Outdoor and indoor air quality and cognitive ability in young children.

    Science.gov (United States)

    Midouhas, Emily; Kokosi, Theodora; Flouri, Eirini

    2018-02-01

    This study examined outdoor and indoor air quality at ages 9 months and 3 years and their association with cognitive ability at age 3 in England and Wales. Data from 8198 Millennium Cohort Study children were analysed using multilevel regression. Outdoor air quality was assessed with mean annual estimates of nitrogen dioxide (NO 2 ) levels within a standard small area (ward). Indoor air quality was measured with parent-reports of damp or condensation in the home and exposure to secondhand smoke in the home. Cognitive ability was assessed with the British Ability Scales Naming Vocabulary subscale and the Bracken School Readiness Assessment. In adjusted models, consistent exposure to high levels of NO 2 at age 9 months and age 3 years was associated with lower verbal ability at age 3 years. Damp/condensation and secondhand smoke in the home at either age or at both ages were correlated with lower school readiness at age 3 years. Exposures to damp/condensation at age 3 years or at both ages and secondhand smoke at either age or at both ages were associated with lower verbal ability at age 3 years. Young children's exposures to indoor damp or condensation and secondhand smoke are likely to be detrimental for their cognitive outcomes. However, there do not appear to be any short-term effects of NO 2 . Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Indoor-Outdoor Detection Using a Smart Phone Sensor.

    Science.gov (United States)

    Wang, Weiping; Chang, Qiang; Li, Qun; Shi, Zesen; Chen, Wei

    2016-09-22

    In the era of mobile internet, Location Based Services (LBS) have developed dramatically. Seamless Indoor and Outdoor Navigation and Localization (SNAL) has attracted a lot of attention. No single positioning technology was capable of meeting the various positioning requirements in different environments. Selecting different positioning techniques for different environments is an alternative method. Detecting the users' current environment is crucial for this technique. In this paper, we proposed to detect the indoor/outdoor environment automatically without high energy consumption. The basic idea was simple: we applied a machine learning algorithm to classify the neighboring Global System for Mobile (GSM) communication cellular base station's signal strength in different environments, and identified the users' current context by signal pattern recognition. We tested the algorithm in four different environments. The results showed that the proposed algorithm was capable of identifying open outdoors, semi-outdoors, light indoors and deep indoors environments with 100% accuracy using the signal strength of four nearby GSM stations. The required hardware and signal are widely available in our daily lives, implying its high compatibility and availability.

  3. Indoor-Outdoor Detection Using a Smart Phone Sensor

    Directory of Open Access Journals (Sweden)

    Weiping Wang

    2016-09-01

    Full Text Available In the era of mobile internet, Location Based Services (LBS have developed dramatically. Seamless Indoor and Outdoor Navigation and Localization (SNAL has attracted a lot of attention. No single positioning technology was capable of meeting the various positioning requirements in different environments. Selecting different positioning techniques for different environments is an alternative method. Detecting the users’ current environment is crucial for this technique. In this paper, we proposed to detect the indoor/outdoor environment automatically without high energy consumption. The basic idea was simple: we applied a machine learning algorithm to classify the neighboring Global System for Mobile (GSM communication cellular base station’s signal strength in different environments, and identified the users’ current context by signal pattern recognition. We tested the algorithm in four different environments. The results showed that the proposed algorithm was capable of identifying open outdoors, semi-outdoors, light indoors and deep indoors environments with 100% accuracy using the signal strength of four nearby GSM stations. The required hardware and signal are widely available in our daily lives, implying its high compatibility and availability.

  4. Measurements of MIMO Indoor Channels at 1800 MHz with Multiple Indoor and Outdoor Base Stations

    Directory of Open Access Journals (Sweden)

    Jaldén Niklas

    2007-01-01

    Full Text Available This paper proposes several configurations for multiple base stations in indoor MIMO systems and compares their performance. The results are based on channel measurements realized with a MIMO testbed. The receiver was moved along several routes and floors on an office building. Both outdoor and indoor locations are considered for the transmitters or base stations, which allow the analysis of not only indoor but also outdoor-to-indoor environment. The use of 2 base stations with different system level combinations of the two is analyzed. We show that the configuration with base station selection provides almost as good performance as a full water-filling scheme when the 2 base stations are placed at different locations. Also the spatial correlation properties for the different configurations are analyzed and the importance of considering path loss when evaluating capacity is highlighted.

  5. Health and economic benefits of building ventilation interventions for reducing indoor PM2.5 exposure from both indoor and outdoor origins in urban Beijing, China.

    Science.gov (United States)

    Yuan, Ye; Luo, Zhiwen; Liu, Jing; Wang, Yaowu; Lin, Yaoyu

    2018-06-01

    China is confronted with serious PM 2.5 pollution, especially in the capital city of Beijing. Exposure to PM 2.5 could lead to various negative health impacts including premature mortality. As people spend most of their time indoors, the indoor exposure to PM 2.5 from both indoor and outdoor origins constitutes the majority of personal exposure to PM 2.5 pollution. Different building interventions have been introduced to mitigate indoor PM 2.5 exposure, but always at the cost of energy expenditure. In this study, the health and economic benefits of different ventilation intervention strategies for reducing indoor PM 2.5 exposure are modeled using a representative urban residence in Beijing, with consideration of different indoor PM 2.5 emission strengths and outdoor pollution. Our modeling results show that the increase of envelope air-tightness can achieve significant economic benefits when indoor PM 2.5 emissions are absent; however, if an indoor PM 2.5 source is present, the benefits only increase slightly in mechanically ventilated buildings, but may show negative benefit without mechanical ventilation. Installing mechanical ventilation in Beijing can achieve annual economic benefits ranging from 200yuan/capita to 800yuan/capita if indoor PM 2.5 sources exist. If there is no indoor emission, the annual benefits above 200yuan/capita can be achieved only when the PM 2.5 filtration efficiency is no urban Beijing will increase the indoor PM 2.5 exposure and result in excess costs to the residents. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. BRIDGING OUTDOOR AND INDOOR ENVIRONMENTAL SIMULATION FOR ASSESSING AND AIDING SUSTAINABLE URBAN NEIGHBOURHOOD DESIGN

    Directory of Open Access Journals (Sweden)

    Chengzhi Peng

    2012-11-01

    Full Text Available Urban dwellers in cities located in hot-arid or hothumid regions have greater needs to live in between outdoor and indoor environments. The sustainability of urban building design in these regions cannot be fully assessed by indoor environmental simulation not taking into account the microclimatic factors of the surrounding urban neighbourhood. We find that the current suites of outdoor and indoor simulation software do not connect with each other to give us a holistic understanding of both outdoor and indoor simulation results. This paper reports on our current development of a methodological framework for bridging the current gap between outdoor and indoor environmental simulation. Our objective is that assessment of sustainability at an urban neighbourhood level can be carried out more holistically, and hence achieving more valid environmental simulations from an urban  dwelling point of view. The outdoor-indoor coupling methodology is currently modelled on a digital work flow among three key software platforms: (1 ENVImet for urban neighbourhood outdoor simulation, (2 Ecotect for building indoor simulation, (3 uCampus for combined outdoor-indoor 3D visualisation modelling of an entire urban neighbourhood including its individual buildings. A case study of a new neighbourhood development proposed for New Cairo is presented to demonstrate how indoor environmental simulation can be grounded on outdoor environmental simulation of the urban neighbourhood. Graphical outputs from this outdoorindoor coupling approach to neighbourhood simulation can be further brought together onto a Web-based 3D virtual reality modelling platform to enable wider accessibility.

  7. Preliminary evaluation, using passive tubes, of carbon monoxide concentrations in outdoor and indoor air at street level shops in Genoa (Italy)

    Science.gov (United States)

    Valerio, Federico; Pala, Mauro; Lazzarotto, Anna; Balducci, Daniele

    Preliminary information on carbon monoxide (CO) concentrations (exposure time: 8 h) both inside and outside 38 randomly selected shops situated on four heavy traffic streets of Genoa was obtained using passive diffusion tubes. Reproducibility and accuracy of this analytical method were tested in real outdoor urban conditions and found within 25%; the detection limit was 1 mgm -3 of CO. The highest mean CO concentrations (15.8 ± 2.2 mgm -3) were found inside shops on Balbi street, a narrow "canyon street". Only in two small shops and two bars (both with many smokers) and in a delicatessen, were indoor CO concentrations significantly higher than outdoor values. The mean outdoor CO concentrations (mgm -3) along the four streets considered (XX Settembre, Balbi, Rolando, Fillak) were 7.4 ± 2.2; 14.5 ± 8.7; 5.8 ± 0.4; 10.5 ± 3.7, respectively. No statistical difference was found, comparing the mean indoor CO concentration with the mean CO outdoor value, measured simultaneously along the sidewalks of each street. CO concentrations in 10 shops without smokers and the nearest outdoor measurements were linearly correlated ( r = 0.99; p statistically significant difference was found comparing indoor CO pollution in shops with smokers (CO: 8.0 ± 5.4) to those without smokers (CO: 7.1 ± 4.6). Forced ventilation, with air intake far from traffic, proved effective in some specific situations in reducing indoor CO concentrations.

  8. Indoor/Outdoor Air Quality Assessment at School near the Steel Plant in Taranto (Italy

    Directory of Open Access Journals (Sweden)

    A. Di Gilio

    2017-01-01

    Full Text Available This study aims to investigate the air quality in primary school placed in district of Taranto (south of Italy, an area of high environmental risk because of closeness between large industrial complex and urban settlement. The chemical characterization of PM2.5 was performed to identify origin of pollutants detected inside school and the comparison between indoor and outdoor levels of PAHs and metals allowed evaluating intrusion of outdoor pollutants or the existence of specific indoor sources. The results showed that the indoor and outdoor levels of PM2.5, BaP, Cd, Ni, As, and Pb never exceeded the target values issued by World Health Organization (WHO. Nevertheless, high metals and PAHs concentrations were detected especially when school were downwind to the steel plant. The I/O ratio showed the impact of outdoor pollutants, especially of industrial markers as Fe, Mn, Zn, and Pb, on indoor air quality. This result was confirmed by values of diagnostic ratio as B(aP/B(gP, IP/(IP + BgP, BaP/Chry, and BaP/(BaP + Chry, which showed range characteristics of coke and coal combustion. However, Ni and As showed I/O ratio of 2.5 and 1.4, respectively, suggesting the presence of indoor sources.

  9. Characterization of short- and medium-chain chlorinated paraffins in outdoor/indoor PM10/PM2.5/PM1.0 in Beijing, China.

    Science.gov (United States)

    Huang, Huiting; Gao, Lirong; Xia, Dan; Qiao, Lin; Wang, Runhua; Su, Guijin; Liu, Wenbin; Liu, Guorui; Zheng, Minghui

    2017-06-01

    Persistent organic pollutants (POPs) were listed in the Stockholm Convention, because of their adverse health effects, persistence, bioaccumulation and ubiquitous presence in the environment. Short chain chlorinated paraffins (SCCPs), chlorinated derivatives of n-alkanes, have been listed as candidate POPs under Stockholm Convention. Inhalation uptake was an important exposure pathway for non-occupational adult human and the pollution of particle matter has caused great concern. There are some studies focused on POPs such as polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins and dibenzofurans and polybrominated diphenyl ethers in different size particles. However, there were no studies that discussed CP concentrations in particulate matter (PM) with different sizes. In this study, a total of 30 PM samples were collected both outdoors and indoors at a sampling site in Beijing. These samples were used to investigate the concentrations and distributions of SCCPs and medium chain chlorinated paraffins (MCCPs) in PM fractions of different sizes, and to evaluate inhalation exposure risks. The results showed that the average SCCPs and MCCPs in the outdoor PM 10 were 23.9 and 3.6 ng m -3 , while the mean values in indoor were 61.1 and 6.9 ng m -3 , respectively. The levels of SCCPs and MCCPs in indoor and outdoor were relatively high. SCCP and MCCP concentrations in the indoor PM 10 /PM 2.5 /PM 1.0 samples were higher than the corresponding values in the outdoor, because of the using of some products containing CPs in the indoors, like paints and coatings, leather and rubber products. In both outdoor and indoor air, CPs are mainly associated with particles ≤2.5 μm in diameter. The main homolog groups for both SCCPs and MCCPs were C 10-11 Cl 7-8 . It is assumed that SCCPs in the outdoor and indoor PM samples may mainly derive from the production and use of CP-42 and CP-52. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Indoor and outdoor poly- and perfluoroalkyl substances (PFASs) in Korea determined by passive air sampler

    International Nuclear Information System (INIS)

    Kim, Seung-Kyu; Shoeib, Mahiba; Kim, Kyeong-Soo; Park, Jong-Eun

    2012-01-01

    Despite concerns to their increasing contribution to ecological and human exposure, the atmospheric levels of poly- and perfluoroalkyl substances (PFASs) have been determined mainly in Europe and North America. This study presents the indoor and outdoor air concentrations of volatile PFASs [fluorotelomer alcohols (FTOHs), and perfluoroalkyl sulfonamides/sulfonamidoethanols/sulfonamide ethyl acetate (FOSAs/FOSEs/FOSEA)] for the first time in Korean cities. In contrast to the good agreement observed for indoor FTOHs levels in Korea and Europea/North America, FOSAs/FOSEs levels were 10–100-fold lower in Korean indoor air, representing a cultural difference of indoor source. Korean outdoor air contained higher PFAS levels than indoor air, and additionally showed different PFAS composition profile from indoor air. Thus, indoor air would not likely be a main contributor to atmospheric PFAS contamination in Korea, in contrast to western countries. Inhalation exposure of volatile PFASs was estimated to be a minor contributor to PFOA and PFOS exposure in Korea. - Highlights: ► Volatile PFASs were measured in indoor and outdoor airs of Korea, for the first time. ► Cultural difference in indoor source was observed for Korea v.s. western countries. ► Furthermore, PFASs concentrations were higher in indoor air than outdoor air. ► Indoor air was not a major contributor to atmospheric PFASs contamination in Korea. ► Release from industrial activities was considered a possible source. - Korean outdoor air showed not only different PFAS composition profile but higher PFAS levels than indoor airs, indicating indoor air would not be a main source to Korean atmospheric PFASs.

  11. Assessment of polycyclic aromatic hydrocarbons in indoor and outdoor air of preschool environments (3–5 years old children)

    International Nuclear Information System (INIS)

    Oliveira, Marta; Slezakova, Klara; Delerue-Matos, Cristina; Pereira, Maria do Carmo; Morais, Simone

    2016-01-01

    This work characterizes levels of polycyclic aromatic hydrocarbons (PAHs) in indoor and outdoor air of preschool environments, and assesses the respective risks for 3–5-years old children. Eighteen gaseous and particulate (PM_1 and PM_2_._5) PAHs were collected indoors and outdoors during 63 days at preschools in Portugal. Gaseous PAHs accounted for 94–98% of total concentration (Σ_P_A_H_s). PAHs with 5–6 rings were predominantly found in PM_1 (54–74% particulate Σ_P_A_H_s). Lighter PAHs originated mainly from indoor sources whereas congeners with 4–6 rings resulted mostly from outdoor emissions penetration (motor vehicle, fuel burning). Total cancer risks of children were negligible according to USEPA, but exceeded (8–13 times) WHO health-based guideline. Carcinogenic risks due to indoor exposure were higher than for outdoors (4–18 times). - Highlights: • Lighter PAHs originate from indoor sources, 4–6 rings PAHs result from outdoors. • Gaseous PAHs account for the majority of PAH content in indoor air of preschools. • Lifetime lung cancer risk values exceed WHO health-based guideline level of 10"−"5. • Carcinogenic risks due to preschool indoor exposure are higher than for outdoors. - This work fills gap providing information on levels, phase distribution (gas, PM_1, PM_2_._5) and risks of polycyclic aromatic hydrocarbons in indoor and outdoor air of preschool settings.

  12. A sensitivity study of parameters in the Nazaroff-Cass IAQ model with respect to indoor concentrations of O3, NO, NO2

    International Nuclear Information System (INIS)

    Drakou, G.; Zerefos, C.; Ziomas, I.

    2000-01-01

    The indoor O 3 , NO, NO 2 concentrations and their corresponding indoor/outdoor (I/O) concentration ratios are predicted in this paper for some representative buildings, using the Nazaroff-Cass indoor air quality models. This paper presents and systemises the relationship between indoor and air pollution concentrations and the buildings' design, use and operation. The building parameters which are determined to be main factors affecting the air pollutant concentrations are: the physical dimensions of the building and the materials of construction, the buildings' air exchange rate with outdoors and the indoor air pollutant sources. Changes of ultraviolet photon fluxes, of temperatures and of relative humidity indoors, have little effect on indoor O 3 , NO and NO 2 concentrations, for air exchange rates above 0.5 ach. Special attention must be given when a building has a very low air exchange rate, under which conditions the effect of a small change in any of the factors determining the indoor air quality of the building will be much more noticeable than in a building with high air exchange rate. (Author)

  13. Indoor and outdoor SO{sub 2} in a community near oil sand extraction and production facilities in northern Alberta

    Energy Technology Data Exchange (ETDEWEB)

    Kindzierski, W.B.; Ranganathan, H.K.S. [Alberta Univ., Edmonton, AB (Canada). Dept. of Civil and Environmental Engineering

    2006-07-01

    In order to examine whether the proximity to several oil sand operations in the Athabasca region has affected the air quality in nearby communities, a baseline study measuring indoor and outdoor sulphur dioxide (SO{sub 2}) levels was conducted in Fort McKay, a small native community located in northern Alberta. The study involved deploying a passive sampling device for 96 hours at 30 randomly chosen homes over a 6 week period such that 75 per cent of homes were sampled during weekdays and 25 per cent during weekends. The common living area of each home (kitchen or family room) was sampled indoors. Outdoor passive samplers were attached to a sampling stand under a shelter in the yard. This article presented an introduction to oil sands development in the region and discussed the link between SO{sub 2} emissions and outdoor air pollution. The passive sampling monitors and study methods were described. Last, the article discussed the results of the study and provided a discussion of quality assurance and quality control; indoor and outdoor SO{sub 2} levels; and air exchange measurements. It was concluded that the results of the testing to determine accuracy and precision of the monitors were both within 35 per cent based on a 96 hour average measurement, which are considered very low and consistent with levels observed elsewhere in Alberta. 43 refs., 5 tabs., 4 figs.

  14. Observations on persistent organic pollutants in indoor and outdoor air using passive polyurethane foam samplers

    Science.gov (United States)

    Bohlin, Pernilla; Jones, Kevin C.; Tovalin, Horacio; Strandberg, Bo

    Air quality data of persistent organic pollutants (POPs) indoors and outdoors are sparse or lacking in several parts of the world, often hampered by the cost and inconvenience of active sampling techniques. Cheap and easy passive air sampling techniques are therefore helpful for reconnaissance surveys. As a part of the Megacity Initiative: Local and Global Research Observations (MILAGRO) project in Mexico City Metropolitan Area in 2006, a range of POPs (polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), and polybrominated diphenyl ethers (PBDEs)) were analyzed in polyurethane foam (PUF) disks used as passive samplers in indoor and outdoor air. Results were compared to those from samplers deployed simultaneously in Gothenburg (Sweden) and Lancaster (United Kingdom). Using sampling rates suggested in the literature, the sums of 13 PAHs in the different sites were estimated to be 6.1-180 ng m -3, with phenanthrene as the predominant compound. Indoor PAH levels tended to be higher in Gothenburg and outdoor levels higher in Mexico City. The sum of PCBs ranged 59-2100 ng m -3, and seemed to be highest indoors in Gothenburg and Lancaster. PBDE levels (sum of seven) ranged 0.68-620 ng m -3, with the highest levels found in some indoor locations. OCPs (i.e. DDTs, HCHs, and chlordanes) were widely dispersed both outdoors and indoors at all three studied areas. In Gothenburg all POPs tended to be higher indoors than outdoors, while indoor and outdoor levels in Mexico City were similar. This could be due to the influence of indoor and outdoor sources, air exchange rates, and lifestyle factors. The study demonstrates how passive samplers can provide quick and cheap reconnaissance data simultaneously at many locations which can shed light on sources and other factors influencing POP levels in air, especially for the gaseous fractions.

  15. Endocrine disrupting chemicals in indoor and outdoor air

    Science.gov (United States)

    Rudel, Ruthann A.; Perovich, Laura J.

    The past 50 years have seen rapid development of new building materials, furnishings, and consumer products and a corresponding explosion in new chemicals in the built environment. While exposure levels are largely undocumented, they are likely to have increased as a wider variety of chemicals came into use, people began spending more time indoors, and air exchange rates decreased to improve energy efficiency. As a result of weak regulatory requirements for chemical safety testing, only limited toxicity data are available for these chemicals. Over the past 15 years, some chemical classes commonly used in building materials, furnishings, and consumer products have been shown to be endocrine disrupting chemicals - that is they interfere with the action of endogenous hormones. These include PCBs, used in electrical equipment, caulking, paints and surface coatings; chlorinated and brominated flame retardants, used in electronics, furniture, and textiles; pesticides, used to control insects, weeds, and other pests in agriculture, lawn maintenance, and the built environment; phthalates, used in vinyl, plastics, fragrances, and other products; alkylphenols, used in detergents, pesticide formulations, and polystyrene plastics; and parabens, used to preserve products like lotions and sunscreens. This paper summarizes reported indoor and outdoor air concentrations, chemical use and sources, and toxicity data for each of these chemical classes. While industrial and transportation-related pollutants have been shown to migrate indoors from outdoor sources, it is expected that indoor sources predominate for these consumer product chemicals; and some studies have identified indoor sources as the predominant factor influencing outdoor ambient air concentrations in densely populated areas. Mechanisms of action, adverse effects, and dose-response relationships for many of these chemicals are poorly understood and no systematic screening of common chemicals for endocrine disrupting

  16. Measurement and health risk assessment of PM2.5, flame retardants, carbonyls and black carbon in indoor and outdoor air in kindergartens in Hong Kong.

    Science.gov (United States)

    Deng, Wen-Jing; Zheng, Hai-Long; Tsui, Anita K Y; Chen, Xun-Wen

    2016-11-01

    Indoor air pollution is closely related to children's health. Polybrominated diphenyl ethers (PBDEs) and dechlorane plus (DP) transmitted through indoor PM 2.5 and dust, along with carbonyl compounds and black carbon (BC) aerosol were analysed in five Hong Kong kindergartens. The results showed that 60% of the median PM 2.5 levels (1.3×10 1 to 2.9×10 1 μg/m 3 for indoor; 9.5 to 8.8×10 1 μg/m 3 for outdoor) in the five kindergartens were higher than the guidelines set by the World Health Organization (2.5×10 1 μg/m 3 ). Indoor PM 2.5 mass concentrations were correlated with outdoor PM 2.5 in four of the kindergartens. The PBDEs (0.10-0.64ng/m 3 in PM 2.5 ; 0.30-2.0×10 2 ng/g in dust) and DP (0.05-0.10ng/m 3 in PM 2.5 ; 1.3-8.7ng/g in dust) were detected in 100% of the PM 2.5 and dust samples. Fire retardant levels in the air were not correlated with the levels of dust in this study. The median BC concentrations varied by >7-fold from 8.8×10 2 ng/m -3 to 6.7×10 3 ng/m -3 and cooking events might have caused BC concentrations to rise both indoors and outdoors. The total concentrations of 16 carbonyls ranged from 4.7×10 1 μg/m 3 to 9.3×10 1 μg/m 3 indoors and from 1.9×10 1 μg/m 3 to 4.3×10 1 μg/m 3 outdoors, whilst formaldehyde was the most abundant air carbonyl. Indoor carbonyl concentrations were correlated with outdoor carbonyls in three kindergartens. The health risk assessment showed that hazard indexes (HIs) HIs of non-cancer risks from PBDEs and DPs were all lower than 0.08, whilst non-cancer HIs of carbonyl compounds ranged from 0.77 to 1.85 indoors and from 0.50 to 0.97 outdoors. The human intake of PBDEs and DP through inhalation of PM 2.5 accounted for 78% to 92% of the total intake. The cancer hazard quotients (HQs) of formaldehyde ranged from 4.5E-05 to 2.1E-04 indoors and from 1.9E-05 to 6.2E-05 outdoors. In general, the indoor air pollution in the five Hong Kong kindergartens might present adverse effects to children, although different

  17. Public effective doses from environmental natural gamma exposures indoors and outdoors in Iran

    International Nuclear Information System (INIS)

    Sohrabi, Mehdi; Roositalab, Jalil; Mohammadi, Jahangir

    2015-01-01

    The effective doses of public in Iran due to external gamma exposures from terrestrial radionuclides and from cosmic radiation indoors and outdoors of normal natural background radiation areas were determined by measurements and by calculations. For direct measurements, three measurement methods were used including a NaI(TI) scintillation survey meter for preliminary screening, a pressurised ionising chamber for more precise measurements and early warning measurement equipment systems. Measurements were carried out in a large number of locations indoors and outdoors ∼1000 houses selected randomly in 36 large cities of Iran. The external gamma doses of public from living indoors and outdoors were also calculated based on the radioactivity measurements of samples taken from soil and building materials by gamma spectrometry using a high-resolution HPGe system. The national mean background gamma dose rates in air indoors and outdoors based on measurements are 126.9±24.3 and 111.7±17.72 nGy h -1 , respectively. When the contribution from cosmic rays was excluded, the values indoors and outdoors are 109.2±20.2 and 70.2±20.59.4 nGy h -1 , respectively. The dose rates determined for indoors and outdoors by calculations are 101.5±9.2 and 72.2±9.4 nGy h -1 , respectively, which are in good agreement with directly measured dose rates within statistical variations. By considering a population-weighted mean for terrestrial radiation, the ratio of indoor to outdoor dose rates is 1.55. The mean annual effective dose of each individual member of the public from terrestrial radionuclides and cosmic radiation, indoors and outdoors, is 0.86±0.16 mSv y -1 by measurements and 0.8±0.2 mSv y -1 by calculations. The results of this national survey of public annual effective doses from national natural background external gamma radiation determined by measurements and calculations indoors and outdoors of 1000 houses in 36 cities of Iran are presented and discussed. (authors)

  18. Polluted air--outdoors and indoors.

    Science.gov (United States)

    Myers, I; Maynard, R L

    2005-09-01

    Many air pollutants which are considered important in ambient (outdoor) air are also found, sometimes at higher levels, in indoor air. With demanding standards having been set for many of these pollutants, both in the workplace and ambient air, consideration of the problems posed by indoor pollution is gaining pace. Studies on exposure to pollutants found in the indoor domestic environment are increasing and are contributing to an already significant compilation of datasets. Improvement in monitoring techniques has helped this process. Documented reports of fatalities from carbon monoxide poisonings are still worrying. However, studies on health effects of non-fatal, long term, low dose, indoor exposure to carbon monoxide and other pollutants, are still inconclusive and too infrequently documented. Of particular concern are the levels of air pollutants found in the domestic indoor environment in developing countries, despite simple interventions such as vented stoves having shown their value. Exposure to biomass smoke is still a level that would be considered unacceptable on health grounds in developed countries. As in the occupational environment, steps need to be taken to control the risks from exposure to the harmful constituents of indoor air in the home. However, the difficulty regarding regulation of the domestic indoor environment is its inherent privacy. Monitoring levels of pollutants in the home and ensuring regulations are adhered to, would likely prove difficult, especially when individual behaviour patterns and activities have the greatest influence on pollutant levels in indoor air. To this end, the Department of Health is developing guidance on indoor air pollution to encourage the reduction of pollutant levels in indoor domestic air. The importance of the effects of domestic indoor air on health and its contribution to the health of the worker are increasingly appreciated. Occupational physicians, by training and interest, are well placed to extend

  19. Source apportionment of indoor, outdoor and personal PM2.5 exposure of pregnant women in Barcelona, Spain

    Science.gov (United States)

    Minguillón, M. C.; Schembari, A.; Triguero-Mas, M.; de Nazelle, A.; Dadvand, P.; Figueras, F.; Salvado, J. A.; Grimalt, J. O.; Nieuwenhuijsen, M.; Querol, X.

    2012-11-01

    Exposure to air pollution has been shown to adversely affect foetal development in the case of pregnant women. The present study aims to investigate the PM composition and sources influencing personal exposure of pregnant women in Barcelona. To this end, indoor, outdoor and personal exposure measurements were carried out for a selection of 54 pregnant women between November 2008 and November 2009. PM2.5 samples were collected during two consecutive days and then analysed for black smoke (BS), major and trace elements, and polycyclic aromatic hydrocarbons (PAHs) concentrations. Personal information such as commuting patterns and cosmetics use was also collected. PM2.5 concentrations were higher for personal samples than for indoor and outdoor environments. Indoor, outdoor and personal BS and sulphate concentrations were strongly correlated, although some specific indoor and outdoor sulphate sources may exist. Average trace elements concentrations were similar indoor, outdoor and for personal exposure, but the correlations were moderate for most of them. Most of the PAHs concentrations showed strong correlations indoor-outdoor. A source apportionment analysis of the PM composition data by means of a Positive Matrix Factorization (PMF) resulted in the identification of six sources for the outdoor and indoor environments: secondary sulphate, fueloil + sea salt (characterized by V, Ni, Na and Mg), mineral, cigarette (characterized by K, Ce, Cd, benzo(k)fluoranthene and benzo(ghi)perylene), road traffic (characterized by BS and low weight PAHs), and industrial (characterized by Pb, Sn, Cu, Mn and Fe). For personal exposure two specific sources were found: cosmetics (characterized by abundance of Ca, Li, Ti and Sr and the absence of Al) and train/subway (characterized by Fe, Mn, Cu and Ba). The contribution of the sources varied widely among women, especially for cigarette (from zero to up to 4 μg m-3), train/subway (up to more than 6 μg m-3) and cosmetics (up to more

  20. Characterization of particle number concentrations and PM2.5 in a school: influence of outdoor air pollution on indoor air.

    Science.gov (United States)

    Guo, Hai; Morawska, Lidia; He, Congrong; Zhang, Yanli L; Ayoko, Godwin; Cao, Min

    2010-07-01

    The impact of air pollution on school children's health is currently one of the key foci of international and national agencies. Of particular concern are ultrafine particles which are emitted in large quantities, contain large concentrations of toxins and are deposited deeply in the respiratory tract. In this study, an intensive sampling campaign of indoor and outdoor airborne particulate matter was carried out in a primary school in February 2006 to investigate indoor and outdoor particle number (PN) and mass concentrations (PM(2.5)), and particle size distribution, and to evaluate the influence of outdoor air pollution on the indoor air. For outdoor PN and PM(2.5), early morning and late afternoon peaks were observed on weekdays, which are consistent with traffic rush hours, indicating the predominant effect of vehicular emissions. However, the temporal variations of outdoor PM(2.5) and PN concentrations occasionally showed extremely high peaks, mainly due to human activities such as cigarette smoking and the operation of mower near the sampling site. The indoor PM(2.5) level was mainly affected by the outdoor PM(2.5) (r = 0.68, p changes to the modal structure of particle number and size distribution, even though the I/O ratio was different for different size classes. The I/O curves had a maximum value for particles with diameters of 100-400 nm under both occupied and unoccupied scenarios, whereas no significant difference in I/O ratio for PM(2.5) was observed between occupied and unoccupied conditions. Inspection of the size-resolved I/O ratios in the preschool centre and the classroom suggested that the I/O ratio in the preschool centre was the highest for accumulation mode particles at 600 nm after school hours, whereas the average I/O ratios of both nucleation mode and accumulation mode particles in the classroom were much lower than those of Aitken mode particles. The findings obtained in this study are useful for epidemiological studies to estimate the

  1. Spatial and indoor/outdoor gradients in urban concentrations of ultrafine particles and PM2.5 mass and chemical components

    Science.gov (United States)

    Zauli Sajani, Stefano; Ricciardelli, Isabella; Trentini, Arianna; Bacco, Dimitri; Maccone, Claudio; Castellazzi, Silvia; Lauriola, Paolo; Poluzzi, Vanes; Harrison, Roy M.

    2015-02-01

    In order to investigate relationships between outdoor air pollution and concentrations indoors, a novel design of experiment has been conducted at two sites, one heavily trafficked and the other residential. The novel design aspect involves the introduction of air directly to the centre of an unoccupied room by use of a fan and duct giving a controlled air exchange rate and allowing an evaluation of particle losses purely due to uptake on indoor surfaces without the losses during penetration of the building envelope which affect most measurement programmes. The rooms were unoccupied and free of indoor sources, and consequently reductions in particle concentration were due to deposition processes within the room alone. Measurements were made of indoor and outdoor concentrations of PM2.5, major chemical components and particle number size distributions. Despite the absence of penetration losses, indoor to outdoor ratios were very similar to those in other studies showing that deposition to indoor surfaces is likely to be the major loss process for indoor air. The results demonstrated a dramatic loss of nitrate in the indoor atmosphere as well as a selective loss of particles in the size range below 50 nm, in comparison to coarser particles. Depletion of indoor particles was greater during a period of cold weather with higher outdoor concentrations probably due to an enhancement of semi-volatile materials in the outdoor particulate matter. Indoor/outdoor ratios for PM2.5 were generally higher at the trafficked site than the residential site, but for particle number were generally lower, reflecting the different chemical composition and size distributions of particles at the two sites.

  2. Meteorological factors influencing on the radon concentrations in indoor and outdoor airs

    International Nuclear Information System (INIS)

    Kojima, Hiroshi

    1989-01-01

    Factors influencing radon concentrations in indoor and outdoor airs are discussed. A balance between source and loss is required in determining the radon concentration. Source refers to as the outdoor and indoor exhalation rate from the ground and the building materials. Loss is caused by turbulent diffusion outdoors and ventilation indoors. A significant factor influencing the exhalation rate of indoor and outdoor radon may be the change in atmospheric pressure. A drop of pressure feeds the high concentration air under the ground or building materials into the open air, and contributes to the increased exhalation rate. The exhalation rate of radon closely depends on the moisture content of the ground or building materials. Up to a certain level of moisture, the radon exhalation increases with increasing moisture content because the emanation power increases by a recoil effect of a fluid present in the internal pores of the materials. Beyond a certain level of moisture, the exhalation decreases rapidly because the pores are filled with water. Radon exhalated from the ground is spread out by turbulent diffusion. The turbulent diffusion may be related to wind velocity and the lapse rate of temperature. There is a remakable difference between indoor and outdoor radon concentrations. The ventilation rate of the house exerted a great effect upon the indoor radon concentration. The ventilation rate is influenced by meteorological factors together with human activities. Of such factors, wind velocity and temperature gradient between indoor and outdoor airs may be the most significant. The correlation coefficients between RaA or radon and some meteorological factors were calculated on the data from the long term measurements on radon and its decay products in and out of a house under normal living conditions. The changes in atmospheric pressure and wind velocity are found to be a significant factor in the variation of concentration of these nuclides. (N.K.)

  3. Prediction of Indoor Air Exposure from Outdoor Air Quality Using an Artificial Neural Network Model for Inner City Commercial Buildings

    Directory of Open Access Journals (Sweden)

    Avril Challoner

    2015-12-01

    Full Text Available NO2 and particulate matter are the air pollutants of most concern in Ireland, with possible links to the higher respiratory and cardiovascular mortality and morbidity rates found in the country compared to the rest of Europe. Currently, air quality limits in Europe only cover outdoor environments yet the quality of indoor air is an essential determinant of a person’s well-being, especially since the average person spends more than 90% of their time indoors. The modelling conducted in this research aims to provide a framework for epidemiological studies by the use of publically available data from fixed outdoor monitoring stations to predict indoor air quality more accurately. Predictions are made using two modelling techniques, the Personal-exposure Activity Location Model (PALM, to predict outdoor air quality at a particular building, and Artificial Neural Networks, to model the indoor/outdoor relationship of the building. This joint approach has been used to predict indoor air concentrations for three inner city commercial buildings in Dublin, where parallel indoor and outdoor diurnal monitoring had been carried out on site. This modelling methodology has been shown to provide reasonable predictions of average NO2 indoor air quality compared to the monitored data, but did not perform well in the prediction of indoor PM2.5 concentrations. Hence, this approach could be used to determine NO2 exposures more rigorously of those who work and/or live in the city centre, which can then be linked to potential health impacts.

  4. Influence of ambient (outdoor) sources on residential indoor and personal PM2.5 concentrations: analyses of RIOPA data.

    Science.gov (United States)

    Meng, Qing Yu; Turpin, Barbara J; Korn, Leo; Weisel, Clifford P; Morandi, Maria; Colome, Steven; Zhang, Junfeng Jim; Stock, Thomas; Spektor, Dalia; Winer, Arthur; Zhang, Lin; Lee, Jong Hoon; Giovanetti, Robert; Cui, William; Kwon, Jaymin; Alimokhtari, Shahnaz; Shendell, Derek; Jones, Jennifer; Farrar, Corice; Maberti, Silvia

    2005-01-01

    The Relationship of Indoor, Outdoor and Personal Air (RIOPA) study was designed to investigate residential indoor, outdoor and personal exposures to several classes of air pollutants, including volatile organic compounds, carbonyls and fine particles (PM2.5). Samples were collected from summer, 1999 to spring, 2001 in Houston (TX), Los Angeles (CA) and Elizabeth (NJ). Indoor, outdoor and personal PM2.5 samples were collected at 212 nonsmoking residences, 162 of which were sampled twice. Some homes were chosen due to close proximity to ambient sources of one or more target analytes, while others were farther from sources. Median indoor, outdoor and personal PM2.5 mass concentrations for these three sites were 14.4, 15.5 and 31.4 microg/m3, respectively. The contributions of ambient (outdoor) and nonambient sources to indoor and personal concentrations were quantified using a single compartment box model with measured air exchange rate and a random component superposition (RCS) statistical model. The median contribution of ambient sources to indoor PM2.5 concentrations using the mass balance approach was estimated to be 56% for all study homes (63%, 52% and 33% for California, New Jersey and Texas study homes, respectively). Reasonable variations in model assumptions alter median ambient contributions by less than 20%. The mean of the distribution of ambient contributions across study homes agreed well for the mass balance and RCS models, but the distribution was somewhat broader when calculated using the mass balance model with measured air exchange rates.

  5. Indoor NO/sub 2/ sampling in a large university campus in Benin city, southern Nigeria, using flames diffusion tubes

    International Nuclear Information System (INIS)

    Ukpebor, E.E.; Sadiku, Y.T.; Ahonkhai, S.I.

    2005-01-01

    Monitoring of NO/sub 2/ in different indoor environments (without cooking and with cooking using different fuels) was done. Flames diffusion tubes were used for the monitoring. The sampling duration was two weeks. The highest NO/sub 2/ concentration of 38.61 ppb (73.74 mug/m3) was monitored in the room where the cooking was done with a gas burner. This was followed by the room with firewood cooking, where the concentration was 36.75 ppb (70.19 mug/m3) and the least concentration of 24.05 ppb (46.80 mug/m3) was noted in the room, where kerosene stove was used for cooking. It is of significance to observe that the WHO annual average guideline value of 40 mug/m3 was exceeded in al the rooms where cooking was done. Levels obtained in this study, therefore, suggest a need for precautionary mitigation. However, the outdoor concentration of NO/sub 2/ was almost the same as that obtained indoors in the rooms without cooking. This suggests high penetration indoors of outdoor NO/sub 2/. A background level of 3.40 ppb (6.49 mug/m3) was established for the environment in Ugbowo, Benin City, Nigeria. (author)

  6. Estimating mortality derived from indoor exposure to particles of outdoor origin.

    Directory of Open Access Journals (Sweden)

    Wenjing Ji

    Full Text Available Following an extensive review of the literature, we further analyze the published data to examine the health effects of indoor exposure to particulate matter (PM of outdoor origin. We obtained data on all-cause, cardiovascular, and respiratory mortality per 10 μg/m3 increase in outdoor PM10 or PM2.5; the infiltration factors for buildings; and estimated time spent outdoors by individuals in the United States, Europe, China, and globally. These data were combined log-linear exposure-response model to estimate the all-cause, cardiovascular, and respiratory mortality of exposure to indoor PM pollution of outdoor origin. Indoor PM pollution of outdoor origin is a cause of considerable mortality, accounting for 81% to 89% of the total increase in mortality associated with exposure to outdoor PM pollution for the studied regions. The findings suggest that enhancing the capacity of buildings to protect occupants against exposure to outdoor PM pollution has significant potential to improve public health outcomes.

  7. Measurements of indoor and outdoor natural radiation exposure rates in model houses

    International Nuclear Information System (INIS)

    Matsuda, Hideharu; Fukaya, Mitsuharu; Minato, Susumu

    1990-01-01

    Natural gamma-ray and cosmic-ray exposure rates were measured indoors and outdoors for 94 model houses of four housing centers in Nagoya to obtain basic data for estimation of the population dose. Influence of the structure of houses on indoor exposure rates and relationship between indoor and outdoor natural gamma-ray exposure rates were studied. Exposure rates were measured with a 1.5'' φ x 4'' NaI (Tl) scintillation counter and a 6''φ spherical plastic scintillation counter. The mean indoor natural gamma-ray exposure rate in ferro-concrete buildings was about 40% higher than that in fireproof wooden houses, about 60% higher than that in light-weight steel-framed buildings, in fireproof wooden houses, it was also about 10% higher than in light-weight steel-framed building. The ratio of indoor to outdoor natural gamma-ray exposure rate was found to be about 0.95±0.15, 0.77±0.10, and 0.72±0.13 for ferro-concrete buildings, fireproof wooden houses and light-weight steel-framed buildings, respectively. The mean indoor cosmic-ray exposure rate in ferro-concrete buildings was 2.8 μR/h, about 18% lower than the outdoors. The indoor cosmic-ray exposure rate in fireproof wooden houses and light-weight steel-framed buildings were 3.2 μR/h, about 6% lower than the outdoors. (author)

  8. Indoor-outdoor concentrations of fine particulate matter in school building microenvironments near a mine tailing deposit

    Directory of Open Access Journals (Sweden)

    Leonardo Martínez

    2016-11-01

    Full Text Available Indoor air quality in school classrooms is a major pediatric health concern because children are highly susceptible to adverse effects from xenobiotic exposure. Fine particulate matter (PM2.5 emitted from mining waste deposits within and near cities in northern Chile is a serious environmental problem. We measured PM2.5 in school microenvironments in urban areas of Chañaral, a coastal community whose bay is contaminated with mine tailings. PM2.5 levels were measured in six indoor and outdoor school environments during the summer and winter of 2012 and 2013. Measurements were taken during school hours on two consecutive days. Indoor PM2.5 concentrations were 12.53–72.38 μg/m3 in the summer and 21.85–100.53 μg/m3 in winter, while outdoor concentrations were 11.86–181.73 μg/m3 in the summer and 21.50–93.07 μg/m3 in winter. Indoor/outdoor ratios were 0.17–2.76 in the summer and 0.64–4.49 in winter. PM2.5 levels were higher in indoor microenvironments during the winter, at times exceeding national and international recommendations. Our results demonstrate that indoor air quality Chañaral school microenvironments is closely associated with outdoor air pollution attributable to the nearby mine tailings. Policymakers should enact environmental management strategies to minimize further environmental damage and mitigate the risks that this pollution poses for pediatric health.

  9. Outdoor air dominates burden of disease from indoor exposures

    DEFF Research Database (Denmark)

    Hänninen, O.; Asikainen, A.; Carrer, P.

    2014-01-01

    Both indoor and outdoor sources of air pollution have significant public health impacts in Europe. Based on quantitative modelling of the burden of disease the outdoor sources dominate the impacts by a clear margin.......Both indoor and outdoor sources of air pollution have significant public health impacts in Europe. Based on quantitative modelling of the burden of disease the outdoor sources dominate the impacts by a clear margin....

  10. Chemical Characterization of the Indoor Air Quality of a University Hospital: Penetration of Outdoor Air Pollutants

    Directory of Open Access Journals (Sweden)

    Paul T. J. Scheepers

    2017-05-01

    Full Text Available For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ. The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two outdoor locations and source samples were collected from a helicopter and an emergency power supply. Volatile organic compounds (VOC, acrolein, formaldehyde, nitrogen dioxide (NO2, respirable particulate matter (PM-4.0 and PM-2.5 and their respective benz(apyrene contents were determined over a period of two weeks. Time-weighted average concentrations of NO2 (4.9–17.4 μg/m3 and formaldehyde (2.5–6.4 μg/m3 were similar on all indoor and outdoor locations. The median concentration VOC in indoor air was 119 μg/m3 (range: 33.1–2450 μg/m3 and was fivefold higher in laboratories (316 μg/m3 compared to offices (57.0 μg/m3. PM-4.0 and benzo(apyrene concentration were lower in buildings serviced by a >99.95% efficiency particle filter, compared to buildings using a standard 80–90% efficiency filter (p < 0.01. No indications were found that support a significant contribution of known local sources such as fuels or combustion engines to any of the IAQ parameters measured in this study. Chemical IAQ was primarily driven by known indoor sources and activities.

  11. Sources and concentrations of indoor nitrogen dioxide in Hamburg (west Germany) and Erfurt (east Germany)

    International Nuclear Information System (INIS)

    Cyrys, J.; Woelke, G.; Wichmann, H.E.; Heinrich, J.; Richter, K.

    2000-01-01

    Here we report indoor and outdoor concentrations of NO 2 for Erfurt and Hamburg and assess the contribution of the most important indoor sources (e.g. the presence of gas cooking ranges, smoking) and outdoor sources (traffic exhaust emissions). We examined the relative contribution of the different sources of NO 2 to the total indoor NO 2 levels in Erfurt and Hamburg. NO 2 indoor concentrations in Hamburg were slightly higher than those in Erfurt (i.e. living room: 15 μg m -3 for Erfurt and 17 μg m -3 for Hamburg). A linear regression model including the variables, place of residence, season and outdoor NO 2 levels, location of the home within the city, housing and occupant characteristics accounted for 38% of the NO 2 variance. The most important predictors of indoor NO 2 concentrations were gas in cooking followed by other characteristics, such as ventilation or outdoor NO 2 level. Residences in which gas was used for cooking, or in which occupants smoked, had substantially higher indoor NO 2 concentrations (41 or 18% increase, respectively). An increase in the outdoor NO 2 concentration from the 25th to the 75th-percentile (17 μg m -3 ) was associated with a 33% increase in the living room NO 2 concentration. Multiple regression analysis for both cities separately illustrated that use of gas for cooking was the major indoor source of NO 2 . This variable caused a similar increase in the indoor NO 2 levels in each city (43% in Erfurt and 47% in Hamburg). However, outdoor sources of NO 2 (motor vehicle traffic) contributed more to indoor NO 2 levels in Hamburg than in Erfurt

  12. Factors affecting the concentration of outdoor particles indoors: Existing data and data needs

    International Nuclear Information System (INIS)

    McKone, T.E.; Thatcher, T.L.; Fisk, W.J.; Sextro, R.G.; Sohn, M.D.; Delp, W.W.; Riley, W.J.

    2002-01-01

    Accurate characterization of particle concentrations indoors is critical to exposure assessments. It is estimated that indoor particle concentrations depend strongly on outdoor concentrations. For health scientists, knowledge of the factors that control the relationship of indoor particle concentrations to outdoor levels is particularly important. In this paper, we identify and evaluate sources of data for those factors that affect the transport to and concentration of outdoor particles indoors. To achieve this goal, we (i) identify and assemble relevant information on how particle behavior during air leakage, HVAC operation, and particle filtration effects indoor particle concentration; (ii) review and evaluate the assembled information to distinguish data that are directly relevant to specific estimates of particle transport from those that are only indirectly useful; and (iii) provide a synthesis of the currently available information on building air-leakage parameters and their effect on indoor particle matter concentrations

  13. Relationships of Indoor, Outdoor, and Personal Air (RIOPA). Part I. Collection methods and descriptive analyses.

    Science.gov (United States)

    Weisel, Clifford P; Zhang, Junfeng; Turpin, Barbara J; Morandi, Maria T; Colome, Steven; Stock, Thomas H; Spektor, Dalia M; Korn, Leo; Winer, Arthur M; Kwon, Jaymin; Meng, Qing Yu; Zhang, Lin; Harrington, Robert; Liu, Weili; Reff, Adam; Lee, Jong Hoon; Alimokhtari, Shahnaz; Mohan, Kishan; Shendell, Derek; Jones, Jennifer; Farrar, L; Maberti, Slivia; Fan, Tina

    2005-11-01

    of many measured VOCs and carbonyl compounds. For several measured species, personal concentrations were higher than either indoor or outdoor concentrations, indicating the presence of some sources closely related to personal activities. For some species there were no significant indoor sources in the majority of the homes; thus indoor concentrations were mainly determined by outdoor concentrations in these homes. The range of distributions of air concentrations for the measured VOCs, formaldehyde and acetaldehyde, PM2.5, and AERs were generally consistent with values reported previously in the literature. Thus associations derived from or models based on this data set that may link the influence of outdoor sources with indoor air concentrations of air toxics and PM2.5 can be relevant to other urban settings. The simultaneous measurements of indoor concentrations, outdoor concentrations, AERs, and room volumes allowed the use of a mass balance model, under the steady-state approximation, to mechanistically examine the relative contributions of indoor and outdoor sources to measured indoor concentrations on a home-by-home basis. Estimated indoor source strengths for VOCs and carbonyl compounds varied widely from home to home, consistent with the indoor-outdoor concentration patterns, as shown in scatter plots. The indoor source estimations agreed with published values for PM2.5 and with the general understanding of sources of VOCs and carbonyl compounds. The source strengths reported here, derived from hundreds of homes, are an important contribution to the literature on exposure to air toxics. For the first time for many compounds, these estimates present a cohesive set of measurements across a range of air toxics in paired indoor, outdoor, and personal samples along with AER and questionnaire results that can be used for future analyses of indoor air quality. The estimation of outdoor contributions to measured indoor concentrations provides insights about the

  14. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Stojanovska, Zdenka; Janevik, Emilija; Taleski, Vaso [Goce Delcev University, Faculty of Medical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Boev, Blazo [Goce Delcev University, Faculty of Natural and Technical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Zunic, Zora S. [University of Belgrade, Institute of Nuclear Sciences ' ' Vinca' ' , Belgrade (Serbia); Ivanova, Kremena; Tsenova, Martina [National Center of Radiobiology and Radiation Protection, Sofia (Bulgaria); Ristova, Mimoza [University in Ss. Cyril and Methodius, Faculty of Natural Sciences and Mathematic, Institute of Physics, Skopje (Macedonia, The Former Yugoslav Republic of); Ajka, Sorsa [Croatian Geological Survey, Zagreb (Croatia); Bossew, Peter [German Federal Office for Radiation Protection, Berlin (Germany)

    2016-05-15

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m{sup 3} for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported. (orig.)

  15. Variability of indoor and outdoor VOC measurements: An analysis using variance components

    International Nuclear Information System (INIS)

    Jia, Chunrong; Batterman, Stuart A.; Relyea, George E.

    2012-01-01

    This study examines concentrations of volatile organic compounds (VOCs) measured inside and outside of 162 residences in southeast Michigan, U.S.A. Nested analyses apportioned four sources of variation: city, residence, season, and measurement uncertainty. Indoor measurements were dominated by seasonal and residence effects, accounting for 50 and 31%, respectively, of the total variance. Contributions from measurement uncertainty (<20%) and city effects (<10%) were small. For outdoor measurements, season, city and measurement variation accounted for 43, 29 and 27% of variance, respectively, while residence location had negligible impact (<2%). These results show that, to obtain representative estimates of indoor concentrations, measurements in multiple seasons are required. In contrast, outdoor VOC concentrations can use multi-seasonal measurements at centralized locations. Error models showed that uncertainties at low concentrations might obscure effects of other factors. Variance component analyses can be used to interpret existing measurements, design effective exposure studies, and determine whether the instrumentation and protocols are satisfactory. - Highlights: ► The variability of VOC measurements was partitioned using nested analysis. ► Indoor VOCs were primarily controlled by seasonal and residence effects. ► Outdoor VOC levels were homogeneous within neighborhoods. ► Measurement uncertainty was high for many outdoor VOCs. ► Variance component analysis is useful for designing effective sampling programs. - Indoor VOC concentrations were primarily controlled by seasonal and residence effects; and outdoor concentrations were homogeneous within neighborhoods. Variance component analysis is a useful tool for designing effective sampling programs.

  16. Outdoor-indoor air pollution in urban environment: Challenges and opportunity

    Directory of Open Access Journals (Sweden)

    Dennis Y.C. eLeung

    2015-01-01

    Full Text Available With the continual improvement in our quality of life, indoor air quality has become an important area of concern in the 21st century. Indoor air quality is affected by many factors including the type and running conditions of indoor pollution sources, ventilation conditions, as well as indoor activities. Studies revealed that the outdoor environment is also an important factor that cannot be neglected for indoor air quality studies. In this review, the indoor and outdoor air pollution relationships obtained from different studies are discussed in order to identify the key factors affecting the indoor air quality. As climate change is recognized as imposing impacts on the environment, how it affects the indoor air quality and the health impacts to the occupants will be evaluated in this paper. The major challenges and opportunities in indoor/outdoor air pollution studies will be highlighted.

  17. Relationship between indoor and outdoor carbonaceous particulates in roadside households

    Energy Technology Data Exchange (ETDEWEB)

    Funasaka, K.; Miyazaki, T.; Tsuruho, K. [Osaka City Institute of Public Health and Environmental Sciences (Japan); Tamura, K. [The National Institute for Minamata Disease, Kumamoto (Japan); Mizuno, T. [Mie University (Japan). Dept. of Chemistry for Materials; Kuroda, K. [Osaka City University Medical School (Japan). Dept. of Preventive Medicine and Environmental Health

    2000-07-01

    Concentrations of particulate matter (PM) and carbonaceous particulates in indoor and outdoor air at roadside private households were measured in Osaka, Japan. The particulate samples were collected on filters using a portable AND sampler capable of separating particles into three different size ranges: over 10 {mu}m, 2-10 {mu}m (coarse) and below 2 {mu}m (fine) in aerodynamic diameter. The filters were weighed and then analyzed for elemental carbon (EC) and organic carbon (OC) by thermal oxidation using a CHN CORDER. The results showed that indoor fine PM concentration is considerably affected by fine EC and the fine EC in indoor air is significantly correlated to that in outdoor air, r = 0.86 (n = 30, p < 0.001). A simple estimation from EC content ratio in diesel exhaust particles indicated that about 30% of indoor particulates of less than 10 {mu}m (PM10) were contributed from diesel exhaust. Additionally, the size characteristics of outdoor PM at roadside and background sites were examined using Andersen Cascade Impactors. (author)

  18. Indoor and Outdoor Surface-Growing Fungi Contamination at Higher Institutional Buildings in a Malaysian University

    Science.gov (United States)

    Er, C. M.; Sunar, N. M.; Leman, A. M.; Khalid, A.; Ali, R.; Zaidi, E.; Azhar, A. T. S.

    2018-04-01

    Surface-growing indoor and outdoor fungi were assessed using swabbing method to investigate the indoor contamination. The painted wall surface samples were collected from two institutional buildings (B1 and B2) of a university in southern Peninsular Malaysia; indoors and outdoors. The mould concentrations varied widely between indoor and outdoor surface samples of both buildings. The total indoor surface-growing mould concentration (8776.49 CFU/cm2) is significantly higher (pair quality parameters (relative humidity, temperature and air velocity) were also measured indoors and outdoors during the study and violation of the guideline provided by ICOP-IAQ 2010 were proven in indoor environment in both buildings. The results of this assessment showed that the indoor environments of both institutional buildings were contaminated by the surface-growing mould. It also suggested the faulty designs and/or usages of building material in these institutional buildings contributed toward the contamination. An innovative solution is needed to correct the problems.

  19. Characterizing health impacts from indoor and outdoor exposure to fine particulates

    DEFF Research Database (Denmark)

    Vigon, Bruce; Fantke, Peter; McKone, Thomas E

    2016-01-01

    Exposure to fine particulate matter (PM2.5) pollution is a major contributor to human disease burden as continuously shown in the Global Burden of Disease study series. Exposures to PM2.5 concentration outdoors and indoors contribute almost equally to this burden. Despite the importance, health...... impacts from exposure to PM2.5 are often excluded from life cycle impact assessment (LCIA) characterization profiles. This is in large part because of the lack of well-vetted harmonized guidance about how to consistently assess the exposures and impacts of indoor and outdoor emissions of PM2.5 and its...... precursors. We present a framework for calculating characterization factors for indoor and outdoor emissions of primary PM2.5 and secondary PM2.5 precursors, and a roadmap for further refining this modelling framework for operational use in LCIA. The framework was developed over the last three years...

  20. Indoor and outdoor urban atmospheric CO2: Stable carbon isotope constraints on mixing and mass balance

    International Nuclear Information System (INIS)

    Yanes, Yurena; Yapp, Crayton J.

    2010-01-01

    Research highlights: → 13 C of indoor CO 2 indicates proportion of C 4 -derived carbon in occupants' diet. → Flux balance model for ventilated rooms shows rapid approach to CO 2 steady-state. → From extant indoor CO 2 data more dietary C 4 carbon in American than European diets. → Local outdoor urban CO 2 increase of 17 ppm in ten years, no change in average 13 C. - Abstract: From July to November 2009, concentrations of CO 2 in 78 samples of ambient air collected in 18 different interior spaces on a university campus in Dallas, Texas (USA) ranged from 386 to 1980 ppm. Corresponding δ 13 C values varied from -8.9 per mille to -19.4 per mille. The CO 2 from 22 samples of outdoor air (also collected on campus) had a more limited range of concentrations from 385 to 447 ppm (avg. = 408 ppm), while δ 13 C values varied from -10.1 per mille to -8.4 per mille (avg.=-9.0 per mille). In contrast to ambient indoor and outdoor air, the concentrations of CO 2 exhaled by 38 different individuals ranged from 38,300 to 76,200 ppm (avg. = 55,100 ppm), while δ 13 C values ranged from -24.8 per mille to -17.7 per mille (avg. = -21.8 per mille). The residence times of the total air in the interior spaces of this study appear to have been on the order of 10 min with relatively rapid approaches (∼30 min) to steady-state concentrations of ambient CO 2 gas. Collectively, the δ 13 C values of the indoor CO 2 samples were linearly correlated with the reciprocal of CO 2 concentration, exhibiting an intercept of -21.8 per mille, with r 2 = 0.99 and p 2 data representing 18 interior spaces (with varying numbers of occupants), and the coincidence of the intercept (-21.8 per mille) with the average δ 13 C value for human-exhaled CO 2 demonstrates simple mixing between two inputs: (1) outdoor CO 2 introduced to the interior spaces by ventilation systems, and (2) CO 2 exhaled by human occupants of those spaces. If such simple binary mixing is a common feature of interior spaces, it

  1. Relationships in indoor/outdoor air pollution

    International Nuclear Information System (INIS)

    Roed, J.

    1985-01-01

    Beryllium-7 and sulphurhexaflourid has been used as tracers in measurements designed to enable an estimate of the ratio of the outdoor to indoor time-integrated concentration for aerosols and non-reactive gasses of outdoor origin with a special reference to the reduction in inhalation dose that can be achieved by staying indoors during a pollution episode, especially a reactor accident. The effect of operating a vacuum cleaner during the pollution episode and airing shortly after is also investigated. Earlier relevant literature is reviewed and shows goos agreement with the results in this study. Protection factor from 1-12 has been found. (author)

  2. Indoor radon concentration and outdoor/indoor pressure difference correlation

    International Nuclear Information System (INIS)

    Cechak, T.; Fronka, A.; Moucka, L.

    2004-01-01

    In the current approach to the radon issue, the radon risk for people living in a building is estimated based on the average indoor radon concentration. Short-term measurements as usually applied fail to reflect the wide range of radon variations arising from ventilation, radon supply and, in particular, human activities in the building. For this reason, efforts are made to find a new approach to the assessment of the quality of a building as a radon barrier, independent of the weather conditions and residential habits. A simple model of radon volume activity entering the building at a constant rate and simultaneously ventilated at a constant rate is applicable to this task. The rate of radon ingress can be regarded as a parameter making it possible to quantify the leakage of structures provided the barrier against the radon in a soil gas. The ventilation rate, on the other hand, characterizes the leakage of the whole building envelope at a given outdoor/indoor pressure difference. A unique measuring technique called the blower door exists whereby a defined pressure difference between the indoor and outdoor atmosphere can be established. Under such conditions both the ventilation rate and the rate of radon ingress can be measured and expressed as a function of the pressure difference. An analysis of the model of a room with a constant ventilation and constant radon supply is presented and the relationship between radon supply and ventilation rate can be assumed. Some experimental results show how the model can be utilized. The real indoor-outdoor air pressure differences, the indoor-soil air pressure differences, and some effects of different ventilation regimes are given. Other experiments, which have been done by using the blower door method, illustrate the possible effects and some restrictions for a routine application are discussed

  3. Estimation of the variations of ventilation rate and indoor radon concentration using the observed wind velocity and indoor-outdoor temperature difference

    International Nuclear Information System (INIS)

    Nagano, Katsuhiro; Inose, Yuichi; Kojima, Hiroshi

    2006-01-01

    The indoor radon concentration in the building depends on the ventilation rate. Measurement results of indoor-outdoor pressure difference showed the ventilation rate correlated closely with the indoor-outdoor pressure difference. The observation results showed that one of factor of indoor-outdoor pressure difference was the wind velocity. When the wind velocity is small, the ventilation rate is affected by the indoor-outdoor temperature difference and the effect depends on the wind velocity. The temporal variation of indoor radon concentration was predicted by the time depending indoor radon balance model and the ventilation rate estimated from the wind velocity and the indoor-outdoor temperature difference. The temporal variations of predicted radon concentration gave good agreement with the experimental values. The measurement method, indoor radon concentration and ventilation rate, factors of temporal variation of ventilation rate, and prediction of indoor radon concentration are reported. (S.Y.)

  4. Fipronil and its degradates in indoor and outdoor dust

    Science.gov (United States)

    Mahler, B.J.; Van Metre, P.C.; Wilson, J.T.; Musgrove, M.; Zaugg, S.D.; Burkhardt, M.R.

    2009-01-01

    Fipronil is a potent insecticide used for control of termites, fleas, roaches, ants, and other pests. We measured fipronil, fipronil sulfide, and desulfinyl fipronil concentrations in indoor and outdoor dust from 24 residences in Austin, Texas. At least one of these three fipronil compounds was detected in every sample. Fipronil accounted for most of the total fipronil (T-fipronil; fipronil+desulfinyl fipronil+fipronil sulfide), followed by desulfinyl fipronil and fipronil sulfide. Nineteen of 24 samples of indoor dust had T-fipronil concentrations less than 270 ??g/kg; the remaining five had concentrations from 1320 to 14,200 ??g/kg. All three of the residences with a dog on which a flea-control product containing fipronil was used were among the five residences with elevated fipronil concentrations. In outdoor dust, all concentrations of T-fipronil were less than 70??g/kg with one exception (430??g/kg). For every residence, the concentration of T-fipronil in indoor dust exceeded that in outdoor dust, and the median concentration of T-fipronil was 15 times higher indoors than outdoors.

  5. Laser-Based and Ultra-Portable Gas Sensor for Indoor and Outdoor Formaldehyde (HCHO) Monitoring

    Science.gov (United States)

    Shutter, J. D.; Allen, N.; Paul, J.; Thiebaud, J.; So, S.; Scherer, J. J.; Keutsch, F. N.

    2017-12-01

    While used as a key tracer of oxidative chemistry in the atmosphere, formaldehyde (HCHO) is also a known human carcinogen and is listed and regulated by the United States EPA as a hazardous air pollutant. Combustion processes and photochemical oxidation of volatile organic compounds (VOCs) are the major outdoor sources of HCHO, and building materials and household products are ubiquitous sources of indoor HCHO. Due to the ease with which humans can be exposed to HCHO, it is imperative to monitor levels of both indoor and outdoor HCHO exposure in both short and long-term studies.High-quality direct and indirect methods of quantifying HCHO mixing ratios exist, but instrument size and user-friendliness can make them cumbersome or impractical for certain types of indoor and long-term outdoor measurements. In this study, we present urban HCHO measurements by using a new, commercially-available, ppbv-level accurate HCHO gas sensor (Aeris Technologies' MIRA Pico VOC Laser-Based Gas Analyzer) that is highly portable (29 cm x 20 cm x 10 cm), lightweight (3 kg), easy-to-use, and has low power (15 W) consumption. Using an ultra-compact multipass cell, an absorption path length of 13 m is achieved, resulting in a sensor capable of achieving ppbv/s sensitivity levels with no significant spectral interferences.To demonstrate the utility of the gas sensor for emissions measurements, a GPS was attached to the sensor's housing in order to map mobile HCHO measurements in real-time around the Boston, Massachusetts, metro area. Furthermore, the sensor was placed in residential and industrial environments to show its usefulness for indoor and outdoor pollution measurements. Lastly, we show the feasibility of using the HCHO sensor (or a network of them) in long-term monitoring stations for hazardous air pollutants.

  6. Estimation of exposure to atmospheric pollutants during pregnancy integrating space-time activity and indoor air levels: does it make a difference?

    Science.gov (United States)

    Marion, OUIDIR; Lise, GIORGIS-ALLEMAND; Sarah, LYON-CAEN; Xavier, MORELLI; Claire, CRACOWSKI; Sabrina, PONTET; Isabelle, PIN; Johanna, LEPEULE; Valérie, SIROUX; Rémy, SLAMA

    2016-01-01

    Studies of air pollution effects during pregnancy generally only consider exposure in the outdoor air at the home address. We aimed to compare exposure models differing in their ability to account for the spatial resolution of pollutants, space-time activity and indoor air pollution levels. We recruited 40 pregnant women in the Grenoble urban area, France, who carried a Global Positioning System (GPS) during up to 3 weeks; in a subgroup, indoor measurements of fine particles (PM2.5) were conducted at home (n=9) and personal exposure to nitrogen dioxide (NO2) was assessed using passive air samplers (n=10). Outdoor concentrations of NO2, and PM2.5 were estimated from a dispersion model with a fine spatial resolution. Women spent on average 16 h per day at home. Considering only outdoor levels, for estimates at the home address, the correlation between the estimate using the nearest background air monitoring station and the estimate from the dispersion model was high (r=0.93) for PM2.5 and moderate (r=0.67) for NO2. The model incorporating clean GPS data was less correlated with the estimate relying on raw GPS data (r=0.77) than the model ignoring space-time activity (r=0.93). PM2.5 outdoor levels were not to moderately correlated with estimates from the model incorporating indoor measurements and space-time activity (r=−0.10 to 0.47), while NO2 personal levels were not correlated with outdoor levels (r=−0.42 to 0.03). In this urban area, accounting for space-time activity little influenced exposure estimates; in a subgroup of subjects (n=9), incorporating indoor pollution levels seemed to strongly modify them. PMID:26300245

  7. Peripheral and gastrointestinal immune systems of healthy cattle raised outdoors at pasture or indoors on a concentrate-based ration.

    Science.gov (United States)

    Lejeune, Alexandre; Monahan, Frank J; Moloney, Aidan P; Earley, Bernadette; Black, Alistair D; Campion, Deirdre P; Englishby, Tanya; Reilly, Petrina; O'Doherty, John; Sweeney, Torres

    2010-03-31

    Despite an increasing preference of consumers for beef produced from more extensive pasture-based production systems and potential human health benefits from the consumption of such beef, data regarding the health status of animals raised on pasture are limited. The objective of this study was to characterise specific aspects of the bovine peripheral and the gastrointestinal muscosal immune systems of cattle raised on an outdoor pasture system in comparison to animals raised on a conventional intensive indoor concentrate-based system. A number of in vitro functional tests of immune cells suggested subtle differences between the animals on the outdoor versus indoor production systems. There was a decrease in the number of neutrophils and monocytes engaged in phagocytosis in outdoor cattle (P outdoor animals (P outdoor animals with elevated levels of serum pepsinogen (P outdoor animals in comparison to the indoor animals. Lower levels of copper and iodine were measured in the outdoor animals in comparison to indoor animals (P < 0.001). Despite distinctly contrasting production systems, only subtle differences were identified in the peripheral immune parameters measured between cattle raised at pasture in comparison to animals raised on a conventional intensive indoor concentrate-based production system.

  8. New insight into the levels, distribution and health risk diagnosis of indoor and outdoor dust-bound FRs in colder, rural and industrial zones of Pakistan.

    Science.gov (United States)

    Khan, Muhammad Usman; Li, Jun; Zhang, Gan; Malik, Riffat Naseem

    2016-09-01

    This is the first robust study designed to probe selected flame retardants (FRs) in the indoor and outdoor dust of industrial, rural and background zones of Pakistan with special emphasis upon their occurrence, distribution and associated health risk. For this purpose, we analyzed FRs such as polybrominated diphenylethers (PBDEs), dechlorane plus (DP), novel brominated flame retardants (NBFRs) and organophosphate flame retardants (OPFRs) in the total of 82 dust samples (indoor and outdoor) collected three from each zone: industrial, rural and background. We found higher concentrations of FRs (PBDEs, DP, NBFRs and OPFRs) in industrial zones as compared to the rural and background zones. Our results reveal that the concentrations of studied FRs are relatively higher in the indoor dust samples being compared with the outdoor dust and they are ranked as: ∑OPFRs > ∑NBFRs > ∑PBDEs > ∑DP. A significant correlation in the FRs levels between the indoor and outdoor dust suggest the potential intermixing of these compounds between them. The principal component analysis/multiple linear regression predicts the percent contribution of FRs from different consumer products in the indoor and outdoor dust of industrial, rural and background zones to trace their source origin. The FRs detected in the background zones reveal the dust-bound FRs suspended in the air might be shifted from different warmer zones or consumers products available/used in the same zones. Hazard quotient (HQ) for FRs via indoor and outdoor dust intake at mean and high dust scenarios to the exposed populations (adults and toddlers) are found free of risk (HQ < 1) in the target zones. Furthermore, our nascent results will provide a baseline record of FRs (PBDEs, DP, NBFRs and OPFRs) concentrations in the indoor and outdoor dust of Pakistan. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. PERSONAL, INDOOR, AND OUTDOOR CONCENTRATIONS OF PM2.5, PARTICULATE NITRATE, AND ELEMENTAL CARBON FOR INDIVIDUALS WITH COPD IN LOS ANGELES, CA

    Science.gov (United States)

    This study characterizes the personal, indoor, and outdoor concentrations of PM2.5 and the major components of PM2.5, including nitrate (NO3-), elemental carbon (EC), and the elements for individuals with chronic obstructive pulmonary disease (COPD) living in Los Angeles, CA. ...

  10. Wintertime indoor air levels of PM10, PM2.5 and PM1 at public places and their contributions to TSP.

    Science.gov (United States)

    Liu, Yangsheng; Chen, Rui; Shen, Xingxing; Mao, Xiaoling

    2004-04-01

    From 26 October 2002 to 8 March 2003, particulate matter (PM) concentrations (total suspended particles [TSP], PM10, PM2.5 and PM1) were measured at 49 public places representing different environments in the urban area of Beijing. The objectives of this study were (1) to characterize the indoor PM concentrations in public places, (2) to evaluate the potential indoor sources and (3) to investigate the contribution of PM10 to TSP and the contributions of PM2.5 and PM1 to PM10. Additionally, The indoor and outdoor particle concentrations in the same type of indoor environment were employed to investigate the I/O level, and comparison was made between I/O levels in different types of indoor environment. Construction activities and traffic condition were the major outdoor sources to influence the indoor particle levels. The contribution of PM10 to TSP was even up to 68.8%, while the contributions of PM2.5 and PM1 to PM10 were not as much as that of PM10 to TSP.

  11. Enhancing integrated indoor/outdoor mobility in a smart campus

    OpenAIRE

    Torres Sospedra, Joaquín; Avariento, Joan; Rambla Risueño, David; Montoliu Colás, Raúl; Casteleyn, Sven; Benedito Bordonau, Mauri; Gould Carlson, Michael; Huerta Guijarro, Joaquín

    2015-01-01

    A Smart City relies on six key factors: Smart Governance, Smart People, Smart Economy, Smart Environment, Smart Living and Smart Mobility. This paper focuses on Smart Mobility by improving one of its key components: positioning. We developed and deployed a novel indoor positioning system (IPS) that is combined with an outdoor positioning system to support seamless indoor and outdoor navigation and wayfinding. The positioning system is implemented as a service in our broader cartography-based ...

  12. Inorganic and carbonaceous components in indoor/outdoor particulate matter in two residential houses in Oslo, Norway.

    Science.gov (United States)

    Lazaridis, Mihalis; Aleksandropoulou, Victoria; Hanssen, Jan Erik; Dye, Christian; Eleftheriadis, Kostantinos; Katsivela, Eleftheria

    2008-03-01

    A detailed analysis of indoor/outdoor physicochemical aerosol properties has been performed. Aerosol measurements were taken at two dwellings, one in the city center and the other in the suburbs of the Oslo metropolitan area, during summer/fall and winter/spring periods of 2002-2003. In this paper, emphasis is placed on the chemical characteristics (water-soluble ions and carbonaceous components) of fine (PM2.5) and coarse (PM2.5-10) particles and their indoor/outdoor relationship. Results demonstrate that the carbonaceous species were dominant in all fractions of the PM10 particles (cut off size: 0.09-11.31 microm) during all measurement periods, except winter 2003, when increased concentrations of water-soluble inorganic ions were predominant because of sea salt transport. The concentration of organic carbon was higher in the fine and coarse PM10 fractions indoors, whereas elemental carbon was higher indoors only in the coarse fraction. In regards to the carbonaceous species, local traffic and secondary organic aerosol formation were, probably, the main sources outdoors, whereas indoors combustion activities such as preparation of food, burning of candles, and cigarette smoking were the main sources. In contrast, the concentrations of water-soluble inorganic ions were higher outdoors than indoors. The variability of water-soluble inorganic ion concentrations outdoors was related to changes in emissions from local anthropogenic sources, long-range transport of particles, sea salt emissions, and resuspension of roadside and soil dusts. In the indoor environment the infiltration of the outdoor air indoors was the major source of inorganic ions.

  13. Characterizing Aggregated Exposure to Primary Particulate Matter: Recommended Intake Fractions for Indoor and Outdoor Sources

    DEFF Research Database (Denmark)

    Fantke, Peter; Jolliet, Olivier; Apte, Joshua Schulz

    2017-01-01

    Exposure to fine particulate matter (PM_(2.5)) from indoor and outdoor sources is a leading environmental contributor to global disease burden. In response, we established under the auspices of the UNEP/SETAC Life Cycle Initiative a coupled indoor-outdoor emission-to-exposure framework to provide...

  14. Influence of environmental factors on indoor radon concentration levels in the basement and ground floor of a building – A case study

    International Nuclear Information System (INIS)

    Xie, Dong; Liao, Maili; Kearfott, Kimberlee J.

    2015-01-01

    A series of experiments was conducted to measure indoor radon concentrations variations and observe any correlations with indoor and outdoor atmospheric parameters for over a period of one year. Indoor environmental parameters and radon concentrations were measured on an hourly basis in a two-story building both in a laboratory on the well-ventilated ground floor and in the basement below it which had negligible ventilation. The monthly average indoor radon concentration value of 29 ± 21 Bq m"−"3 in the laboratory was below the ICRP recommended limit of 200–300 Bq m"−"3. The monthly normalization factor for that location ranged from 0.5 to 2.0, while the seasonal normalization factor ranged from 0.78 to 2.0. In the unventilated basement, however, the average monthly indoor radon concentration was 1083 ± 6 Bq m"−"3 with little seasonal variation. The basement is only used for storage and thus the elevated radon concentration does not pose a serious health risk. The results indicated that indoor radon levels are higher in the autumn–winter season than in the spring–summer season. Analysis further showed that indoor radon concentrations negatively correlated with indoor humidity (correlation coefficient R = −0.14, p < 0.01), outdoor temperature (correlation coefficient R = −0.3, p < 0.01), outdoor dew point temperature (correlation coefficient R = −0.17, p < 0.01) and outdoor wind speeds (correlation coefficient R = −0.25, p < 0.05). Radon concentrations correlated positively with outdoor barometric pressure (correlation coefficient R = 0.35, p < 0.01), indoor–outdoor temperature difference (correlation coefficient R = 0.32, p < 0.05) and indoor–outdoor barometric pressure difference (correlation coefficient R = 0.67, p < 0.01). Indoor temperature, indoor barometric pressure and outdoor wind direction showed no clear correlations with indoor radon concentration. - Highlights: • Environmental variables and

  15. Indoor air pollution levels in public buildings in Thailand and exposure assessment.

    Science.gov (United States)

    Klinmalee, Aungsiri; Srimongkol, Kasama; Kim Oanh, Nguyen Thi

    2009-09-01

    Levels of pollutants including PM2.5 and PM2.5 composition (black carbon and water soluble ions), SO(2), NO(2), CO, CO(2), and BTEX (benzene, toluene, ethylbenzene, xylene) were monitored for indoor and outdoor air at a university campus and a shopping center, both located in the Northern suburb of Bangkok. Sampling was done during December 2005-February 2006 on both weekdays and weekends. At the university, indoor monitoring was done in two different air conditioned classrooms which shows the I/O ratios for all pollutants to be below 0.5-0.8 during the weekends. However, on weekdays the ratios for CO(2) and most detected BTEX were above 1.0. The concept of classroom occupancy was defined using a function of the student number in a lecture hour and the number of lecture hours per day. Classroom 2, which had a higher occupancy than classroom 1, was characterized by higher concentrations of most pollutants. PM2.5 was an exception and was higher in classroom 1 (37 microg/m(3), weekdays) as compared to classroom 2 (26 microg/m(3), weekdays) which was likely linked to the dust resuspension from the carpeted floor in the former. Monitoring was also done in the shopping mall at three different sites. Indoor pollutants levels and the I/O ratios at the shopping mall were higher than at the university. Levels of all pollutants measured at the car park, except for toluene and CO(2), were the highest. I/O ratios of the pollutants at the mall were above 1.0, which indicates the relatively higher influence of the indoor sources. However, the black carbon content in PM2.5 outdoor is higher than indoor, which suggest the important contribution from outdoor combustion sources such as the traffic. Major sources of outdoor air pollution in the areas were briefly discussed. Exposure modeling was applied using the time activity and measured pollutant concentrations to assess the exposure of different groups of people in the study areas. High exposure to PM2.5, especially for the people

  16. Influences of Green Outdoors versus Indoors Environmental Settings on Psychological and Social Outcomes of Controlled Exercise

    Science.gov (United States)

    Rogerson, Mike; Gladwell, Valerie F.; Gallagher, Daniel J.; Barton, Jo L.

    2016-01-01

    This study addressed a methodological gap by comparing psychological and social outcomes of exercise in green outdoors versus built indoors settings, whilst rigorously controlling exercise mode and intensity. The hypotheses were that greater improvements or more desirable values for directed attention, mood, perceived exertion, social interaction time, intention for future exercise behaviour and enjoyment would be associated with outdoors compared to indoors exercise. Following a baseline session, paired participants completed two conditions of 15 min of cycling on an ergometer placed outside in a natural environment and inside in a laboratory setting in a randomized, counter-balanced order. At pre- and post-exercise, directed attention was measured with the digit span backwards task, and mood was assessed with the Profile of Mood States. During the exercise session, visual and verbal interactions were recorded by means of experimenter observations. After each exercise session, participants provided self-reports of their enjoyment of the exercise, perceived exertion and intention for future exercise in the same environment. Social interaction time was significantly greater during outdoors exercise versus indoors; on average, participants engaged in three minutes more social interaction during exercise outdoors compared to indoors. Social interaction time significantly predicted intention for future exercise in the outdoors condition, but did not in the indoor condition. There was a significant time by condition interaction for directed attention. Scores worsened in the indoors condition, but improved in the outdoors condition. There was no statistically-significant time by condition interaction for mood and no significant difference between conditions for either perceived exertion or intention. Taken together, these findings show that exercise in a natural environment may promote directed attention and social interactions, which may positively influence future

  17. Relationships of outdoor and indoor ultrafine particles at residences downwind of a major international border crossing in Buffalo, NY.

    Science.gov (United States)

    McAuley, T R; Fisher, R; Zhou, X; Jaques, P A; Ferro, A R

    2010-08-01

    During winter 2006, indoor and outdoor ultrafine particle (UFP) size distribution measurements for particles with diameters from 5.6 to 165 nm were taken at five homes in a neighborhood directly adjacent to the Peace Bridge Complex (PBC), a major international border crossing connecting Buffalo, New York to Fort Erie, Ontario. Monitoring with 1-s time resolution was conducted for several hours at each home. Participants were instructed to keep all external windows and doors closed and to refrain from cooking, smoking, or other activity that may result in elevating the indoor UFP number concentration. Although the construction and age for the homes were similar, indoor-to-outdoor comparisons indicate that particle infiltration rates varied substantially. Overall, particle concentrations indoors were lower and less variable than particle concentrations outdoors, with average indoor-outdoor ratios ranging from 0.1 to 0.5 (mean 0.34) for particles between 5.6 and 165 nm in diameter. With no indoor sources, the average indoor-outdoor ratios were lowest (0.2) for 20-nm particles, higher (0.3) for particles <10 nm, and highest (0.5) for particles 70-165 nm. This study provides insight into the penetration of UFP into homes and the resulting change in particle size distributions as particles move indoors near a major diesel traffic source. Although people spend most of their time in their homes, exposure estimates for epidemiological studies are generally determined using ambient concentrations. The findings of this study will contribute to improved size-resolved UFP exposure estimates for near roadway exposure assessments and epidemiological studies.

  18. Polycyclic aromatic hydrocarbons and their derivatives in indoor and outdoor air in an eight-home study

    Science.gov (United States)

    Chuang, Jane C.; Mack, Gregory A.; Kuhlman, Michael R.; Wilson, Nancy K.

    A pilot field study was performed in Columbus, OH, during the winter of 1986/1987. The objectives were to determine the feasibility of the use of a newly developed quiet sampler in indoor air sampling for particles and semivolatile organic compounds (SVOC) and to measure the concentrations of polycyclic aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in air in selected residences. Eight homes were chosen for sampling on the basis of these characteristics: electric/gas heating system, electric/gas cooking appliances, and the absence/presence of environmental tobacco smoke (ETS). The indoor sampler was equipped with a quartz-fiber filter to collect particles followed by XAD-4 resin to trap SVOC. A PS-1 sampler with a similar sampling module was used outdoors. The indoor air was sampled in the kitchen and living room areas over two consecutive 8-h periods. The outdoor air was sampled concurrently with the indoor samples over a 16-h period. Fifteen PAH, five nitro-PAH, five oxygenated PAH, and three nitrogen heterocyclic compounds were determined in these samples. The most abundant PAH found indoors was naphthalene. The indoor concentrations of PAH derivatives were lower than those of their parent compounds. Average concentrations of all but three target compounds (naphthalene dicarboxylic acid anhydride, pyrene dicarboxylic acid anhydride, and 2-nitrofluoranthene) were higher indoors than outdoors. Environmental tobacco smoke was the most significant influence on indoor pollutant levels. Homes with gas heating systems had higher indoor pollutant levels than homes with electric heating systems. However, the true effects of heating and cooking systems were not characterized as accurately as the effects of ETS because of the small sample sizes and the lack of statistical significance for most pollutant differences in the absence of ETS. The concentrations of PAH marker compounds (phenanthrene, fluoranthene, and pyrene) correlated well with the concentrations

  19. Comparison of Indoor Mercury Vapor in Common Areas of Residential Buildings with Outdoor Levels in a Community Where Mercury Is Used for Cultural Purposes

    Science.gov (United States)

    Garetano, Gary; Gochfeld, Michael; Stern, Alan H.

    2006-01-01

    Elemental mercury has been imbued with magical properties for millennia, and various cultures use elemental mercury in a variety of superstitious and cultural practices, raising health concerns for users and residents in buildings where it is used. As a first step in assessing this phenomenon, we compared mercury vapor concentration in common areas of residential buildings versus outdoor air, in two New Jersey cities where mercury is available and is used in cultural practices. We measured mercury using a portable atomic absorption spectrometer capable of quantitative measurement from 2 ng/m3 mercury vapor. We evaluated the interior hallways in 34 multifamily buildings and the vestibule in an additional 33 buildings. Outdoor mercury vapor averaged 5 ng/m3; indoor mercury was significantly higher (mean 25 ng/m3; p < 0.001); 21% of buildings had mean mercury vapor concentration in hallways that exceeded the 95th percentile of outdoor mercury vapor concentration (17 ng/m3), whereas 35% of buildings had a maximum mercury vapor concentration that exceeded the 95th percentile of outdoor mercury concentration. The highest indoor average mercury vapor concentration was 299 ng/m3, and the maximum point concentration was 2,022 ng/m3. In some instances, we were able to locate the source, but we could not specifically attribute the elevated levels of mercury vapor to cultural use or other specific mercury releases. However, these findings provide sufficient evidence of indoor mercury source(s) to warrant further investigation. PMID:16393659

  20. Measurements of environmental radon - 222 concentrations in indoors and outdoors in Egypt

    International Nuclear Information System (INIS)

    Kenawy, M.A.; Morsey, A.A.; Kotb, M.A.; Osman, A.; El-Haag, A.

    1990-01-01

    The major contribution to population exposure from natural radiation arises from the inhalation of the decay products of radon. Substantial surveys are being conducted by several investigators to estimate the indoor and outdoor exposure nationally and to discover regional variations. In this work, radon concentration in the indoors and outdoor air was determined using the can technique and employing CR-39 solid state nuclear track detector for lengthy exposures. The range of radon - 222 activity in this survey was 54 -299 PCi.m -3 in Cairo, 22 - 171 PCi.m -3 in Alexandria and 89 - 370 PCi.m -3 in Asiut. Measurements carried out in Aswan and Sinai ranged between 98 - 411 PCi.m -3 . Values of indoors and outdoors radon concentrations were found to vary with time of day, geographic location, season and height above ground. Further work is going on to study the different parameters affecting the levels of the environmental radon. The national survey and associated studies is expected to yield data that may correlate radon activity with some respiratory diseases, particularly lung cancer. (author). 7 refs, 5 figs

  1. Estimation of outdoor and indoor effective dose and excess lifetime cancer risk from Gamma dose rates in Gonabad, Iran

    Energy Technology Data Exchange (ETDEWEB)

    Jafaria, R.; Zarghania, H.; Mohammadia, A., E-mail: rvzreza@gmail.com [Paramedical faculty, Birjand University of Medical Sciences, Birjand (Iran, Islamic Republic of)

    2017-07-01

    Background gamma irradiation in the indoor and outdoor environments is a major concern in the world. The study area was Gonabad city. Three stations and buildings for background radiation measurement of outdoor and indoor were randomly selected and the Geiger-Muller detector (X5C plus) was used. All dose rates on display of survey meter were recorded and mean of all data in each station and buildings was computed and taken as measured dose rate of that particular station. The average dose rates of background radiation were 84.2 nSv/h for outdoor and 108.6 nSv/h for indoor, maximum and minimum dose rates were 88.9 nSv/h and 77.7 nSv/h for outdoor measurements and 125.4 nSv/h and 94.1 nSv/h for indoor measurements, respectively. Results show that the annual effective dose is 0.64 mSv, which compare to global level of the annual effective dose 0.48 mSv is high. Estimated excess lifetime cancer risk was 2.24×10{sup -3} , indicated that it is large compared to the world average value of 0.25×10{sup -3}. (author)

  2. Toxicity and elemental composition of particulate matter from outdoor and indoor air of elementary schools in Munich, Germany.

    Science.gov (United States)

    Oeder, S; Dietrich, S; Weichenmeier, I; Schober, W; Pusch, G; Jörres, R A; Schierl, R; Nowak, D; Fromme, H; Behrendt, H; Buters, J T M

    2012-04-01

    Outdoor particulate matter (PM(10)) is associated with detrimental health effects. However, individual PM(10) exposure occurs mostly indoors. We therefore compared the toxic effects of classroom, outdoor, and residential PM(10). Indoor and outdoor PM(10) was collected from six schools in Munich during teaching hours and in six homes. Particles were analyzed by scanning electron microscopy and X-ray spectroscopy (EDX). Toxicity was evaluated in human primary keratinocytes, lung epithelial cells and after metabolic activation by several human cytochromes P450. We found that PM(10) concentrations during teaching hours were 5.6-times higher than outdoors (117 ± 48 μg/m(3) vs. 21 ± 15 μg/m(3), P particle number), organic (29%, probably originating from human skin), and Ca-carbonate particles (12%, probably originating from paper). Outdoor PM contained more Ca-sulfate particles (38%). Indoor PM at 6 μg/cm(2) (10 μg/ml) caused toxicity in keratinocytes and in cells expressing CYP2B6 and CYP3A4. Toxicity by CYP2B6 was abolished with the reactive oxygen species scavenger N-acetylcysteine. We concluded that outdoor PM(10) and indoor PM(10) from homes were devoid of toxicity. Indoor PM(10) was elevated, chemically different and toxicologically more active than outdoor PM(10). Whether the effects translate into a significant health risk needs to be determined. Until then, we suggest better ventilation as a sensible option. Indoor air PM(10) on an equal weight base is toxicologically more active than outdoor PM(10). In addition, indoor PM(10) concentrations are about six times higher than outdoor air. Thus, ventilation of classrooms with outdoor air will improve air quality and is likely to provide a health benefit. It is also easier than cleaning PM(10) from indoor air, which has proven to be tedious. © 2011 John Wiley & Sons A/S.

  3. Evaluación de la calidad del aire interior y exterior en un jardín de niños de la Ciudad de México Evaluation of indoor and outdoor air quality of a nursery school in Mexico City

    Directory of Open Access Journals (Sweden)

    Marlene Cortez-Lugo

    1998-09-01

    Full Text Available Objetivo. Evaluar las diferencias en los niveles de ozono (O3 y bióxido de nitrógeno (NO2 en el interior y el exterior de una escuela en el suroeste de la Ciudad de México. Material y métodos. Se midieron diariamente estos contaminantes dentro y fuera del salón, de enero a abril de 1990, mediante monitoreo manual. Resultados. El NO2 adentro y afuera no sobrepasó la norma mexicana (0.21 ppm. El coeficiente de correlación entre las concentraciones máximas de NO2 de la estación de monitoreo local de la ciudad y el exterior del salón fue de 0.82 (pObjective. To evaluate the differences between indoor and outdoor ozone (O3 and nitrogen dioxide (NO2 levels at a school located in southwest Mexico City. Material and methods. Indoor and outdoor O3 and NO2 levels were measured daily between January and April 1990 by manual monitoring. Results. Indoor and outdoor concentrations of nitrogen dioxide did not surpass the Mexican standard (0.21 ppm. The correlation coefficient between maximum NO2 concentrations measured by the city’s local monitoring station and those measured outside the classroom was 0.82 (p< 0.001. Regarding ozone, its maximum outdoor concentration was 0.29 ppm and indoor concentrations were on average below 0.06 ppm (maximum = 0.17 ppm. The indoor/outdoor correlation coefficient was 0.72, and for every 1.7 ppm outside, there was 1.0 ppm inside (p< 0.05 Conclusions. Since the highest outdoors O3 concentrations were observed between 11:00 and 14:00 hrs, it is recommendable to have recess before this time.

  4. Indoor particle levels in small- and medium-sized commercial buildings in California.

    Science.gov (United States)

    Wu, Xiangmei May; Apte, Michael G; Bennett, Deborah H

    2012-11-20

    This study monitored indoor and outdoor particle concentrations in 37 small and medium commercial buildings (SMCBs) in California with three buildings sampled on two occasions, resulting in 40 sampling days. Sampled buildings included offices, retail establishments, restaurants, dental offices, and hair salons, among others. Continuous measurements were made for both ultrafine and fine particulate matter as well as black carbon inside and outside of the building. Integrated PM(2.5), PM(2.5-10), and PM(10) samples were also collected inside and outside the building. The majority of the buildings had indoor/outdoor (I/O) particle concentration ratios less than 1.0, indicating that contributions from indoor sources are less than removal of outdoor particles. However, some of the buildings had I/O ratios greater than 1, indicating significant indoor particle sources. This was particularly true of restaurants, hair salons, and dental offices. The infiltration factor was estimated from a regression analysis of indoor and outdoor concentrations for each particle size fraction, finding lower values for ultrafine and coarse particles than for submicrometer particles, as expected. The I/O ratio of black carbon was used as a relative measure of the infiltration factor of particles among buildings, with a geometric mean of 0.62. The contribution of indoor sources to indoor particle levels was estimated for each building.

  5. Hospital indoor PM10/PM2.5 and associated trace elements in Guangzhou, China

    International Nuclear Information System (INIS)

    Wang Xinhua; Bi Xinhui; Sheng Guoying; Fu Jiamo

    2006-01-01

    PM10 and PM2.5 samples were collected in the indoor environments of four hospitals and their adjacent outdoor environments in Guangzhou, China during the summertime. The concentrations of 18 target elements in particles were also quantified. The results showed that indoor PM2.5 levels with an average of 99 μg m -3 were significantly higher than outdoor PM2.5 standard of 65 μg m -3 recommended by USEPA [United States Environmental Protection Agency. Office of Air and Radiation, Office of Air Quality Planning and Standards, Fact Sheet. EPA's Revised Particulate Matter Standards, 17, July 1997] and PM2.5 constituted a large fraction of indoor respirable particles (PM10) by an average of 78% in four hospitals. High correlation between PM2.5 and PM10 (R 2 of 0.87 for indoors and 0.90 for outdoors) suggested that PM2.5 and PM10 came from similar particulate emission sources. The indoor particulate levels were correlated with the corresponding outdoors (R 2 of 0.78 for PM2.5 and 0.67 for PM10), demonstrating that outdoor infiltration could lead to direct transportation into indoors. In addition to outdoor infiltration, human activities and ventilation types could also influence indoor particulate levels in four hospitals. Total target elements accounted for 3.18-5.56% of PM2.5 and 4.38-9.20% of PM10 by mass, respectively. Na, Al, Ca, Fe, Mg, Mn and Ti were found in the coarse particles, while K, V, Cr, Ni, Cu, Zn, Cd, Sn, Pb, As and Se existed more in the fine particles. The average indoor concentrations of total elements were lower than those measured outdoors, suggesting that indoor elements originated mainly from outdoor emission sources. Enrichment factors (EF) for trace element were calculated to show that elements of anthropogenic origins (Zn, Pb, As, Se, V, Ni, Cu and Cd) were highly enriched with respect to crustal composition (Al, Fe, Ca, Ti and Mn). Factor analysis was used to identify possible pollution source-types, namely street dust, road traffic and

  6. Hospital indoor PM10/PM2.5 and associated trace elements in Guangzhou, China.

    Science.gov (United States)

    Wang, Xinhua; Bi, Xinhui; Sheng, Guoying; Fu, Jiamo

    2006-07-31

    PM10 and PM2.5 samples were collected in the indoor environments of four hospitals and their adjacent outdoor environments in Guangzhou, China during the summertime. The concentrations of 18 target elements in particles were also quantified. The results showed that indoor PM2.5 levels with an average of 99 microg m(-3) were significantly higher than outdoor PM2.5 standard of 65 microg m(-3) recommended by USEPA [United States Environmental Protection Agency. Office of Air and Radiation, Office of Air Quality Planning and Standards, Fact Sheet. EPA's Revised Particulate Matter Standards, 17, July 1997] and PM2.5 constituted a large fraction of indoor respirable particles (PM10) by an average of 78% in four hospitals. High correlation between PM2.5 and PM10 (R(2) of 0.87 for indoors and 0.90 for outdoors) suggested that PM2.5 and PM10 came from similar particulate emission sources. The indoor particulate levels were correlated with the corresponding outdoors (R(2) of 0.78 for PM2.5 and 0.67 for PM10), demonstrating that outdoor infiltration could lead to direct transportation into indoors. In addition to outdoor infiltration, human activities and ventilation types could also influence indoor particulate levels in four hospitals. Total target elements accounted for 3.18-5.56% of PM2.5 and 4.38-9.20% of PM10 by mass, respectively. Na, Al, Ca, Fe, Mg, Mn and Ti were found in the coarse particles, while K, V, Cr, Ni, Cu, Zn, Cd, Sn, Pb, As and Se existed more in the fine particles. The average indoor concentrations of total elements were lower than those measured outdoors, suggesting that indoor elements originated mainly from outdoor emission sources. Enrichment factors (EF) for trace element were calculated to show that elements of anthropogenic origins (Zn, Pb, As, Se, V, Ni, Cu and Cd) were highly enriched with respect to crustal composition (Al, Fe, Ca, Ti and Mn). Factor analysis was used to identify possible pollution source-types, namely street dust, road traffic

  7. Who children spend time with after school: associations with objectively recorded indoor and outdoor physical activity

    Science.gov (United States)

    2014-01-01

    Background Understanding how the determinants of behaviour vary by context may support the design of interventions aiming to increase physical activity. Such factors include independent mobility, time outdoors and the availability of other children. At present little is known about who children spend their time with after school, how this relates to time spent indoors or outdoors and activity in these locations. This study aimed to quantify who children spend their time with when indoors or outdoors and associations with moderate to vigorous physical activity (MVPA). Methods Participants were 427 children aged 10–11 from Bristol, UK. Physical activity was recorded using an accelerometer (Actigraph GT1M) and matched to Global Positioning System receiver (Garmin Foretrex 201) data to differentiate indoor and outdoor location. Children self-reported who they spent time with after school until bed-time using a diary. Each 10 second epoch was coded as indoors or outdoors and for ‘who with’ (alone, friend, brother/sister, mum/dad, other grown-up) creating 10 possible physical activity contexts. Time spent and MVPA were summarised for each context. Associations between time spent in the different contexts and MVPA were examined using multiple linear regression adjusting for daylight, age, deprivation and standardised body mass index. Results During the after school period, children were most often with their mum/dad or alone, especially when indoors. When outdoors more time was spent with friends (girls: 32.1%; boys: 28.6%) than other people or alone. Regression analyses suggested hours outdoors with friends were positively associated with minutes of MVPA for girls (beta-coefficient [95% CI]: 17.4 [4.47, 30.24]) and boys (17.53 [2.76, 32.31]). Being outdoors with brother/sister was associated with MVPA for girls (21.2 [14.17, 28.25]) but not boys. Weaker associations were observed for time indoors with friends (girls: 4.61 [1.37, 7.85]; boys: (7.42 [2.99, 11

  8. Reduction of outdoor and indoor ambient dose equivalent after decontamination in the Fukushima evacuation zones

    International Nuclear Information System (INIS)

    Yoshida-Ohuchi, Hiroko; Kanagami, Takashi; Naitoh, Yutaka; Kameyama, Mizuki; Hosoda, Masahiro

    2017-01-01

    One of the most urgent issues following the accident at the Fukushima Daiichi nuclear power plant (FDNPP) was the remediation of the land, in particular, for residential area contaminated by the radioactive materials discharged. In this study, the effect of decontamination on reduction of ambient dose equivalent outdoors and indoors was evaluated. The latter is essential for residents as most individuals spend a large portion of their time indoors. From December 2012 to November 2014, thirty-seven Japanese single-family detached wooden houses were investigated before and after decontamination in evacuation zones. Outdoor and indoor dose measurements (n=84 and 114, respectively) were collected based on in situ measurements using the NaI (Tl) scintillation surveymeter. The outdoor ambient dose equivalents [H"*(10)_o_u_t] ranged from 0.61 to 3.71 μSv h"-"1 and from 0.23 to 1.32 μSv h"-"1 before and after decontamination, respectively. The indoor ambient dose equivalents [H"*(10)"i"n] ranged from 0.29 to 2.53 μSv h"-"1 and from 0.16 to 1.22 μSv h"-"1 before and after decontamination, respectively. The values of reduction efficiency (RE), defined as the ratio by which the radiation dose has been reduced via decontamination, were evaluated as 0.47±0.13, 0.51±0.13, and 0.58±0.08 (average±σ) when H"*(10)_o_u_t <1.0 μSv h"-"1, 1.0 μSv h"-"1 < H"*(10)_o_u_t <2.0 μSv h"-"1, and 2.0 μSv h"-"1< H"*(10)_o_u_t, respectively, indicating the values of RE increased as H"*(10)_o_u_t increased. It was found that the values of RE were 0.53±0.12 outdoors and 0.41±0.09 indoors, respectively, indicating RE was larger outdoors than indoors. Indoor dose is essential as most individuals spend a large portion of their time indoors. The difference between outdoors and indoors should be considered carefully in order to estimate residents’ exposure dose before their returning home

  9. Reduction of outdoor and indoor ambient dose equivalent after decontamination in the Fukushima evacuation zones

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida-Ohuchi, Hiroko; Kanagami, Takashi [Graduate School of Pharmaceutical Sciences, Tohoku University, Miyagi (Japan); Naitoh, Yutaka; Kameyama, Mizuki [Japan Environment Research Co., Ltd., Miyagi (Japan); Hosoda, Masahiro [Dept. of Radiological Life Sciences, Hirosaki University Graduate School of Health Sciences, Aomori (Japan)

    2017-03-15

    One of the most urgent issues following the accident at the Fukushima Daiichi nuclear power plant (FDNPP) was the remediation of the land, in particular, for residential area contaminated by the radioactive materials discharged. In this study, the effect of decontamination on reduction of ambient dose equivalent outdoors and indoors was evaluated. The latter is essential for residents as most individuals spend a large portion of their time indoors. From December 2012 to November 2014, thirty-seven Japanese single-family detached wooden houses were investigated before and after decontamination in evacuation zones. Outdoor and indoor dose measurements (n=84 and 114, respectively) were collected based on in situ measurements using the NaI (Tl) scintillation surveymeter. The outdoor ambient dose equivalents [H{sup *}(10){sub out}] ranged from 0.61 to 3.71 μSv h{sup -1} and from 0.23 to 1.32 μSv h{sup -1} before and after decontamination, respectively. The indoor ambient dose equivalents [H{sup *}(10){sup in}] ranged from 0.29 to 2.53 μSv h{sup -1} and from 0.16 to 1.22 μSv h{sup -1} before and after decontamination, respectively. The values of reduction efficiency (RE), defined as the ratio by which the radiation dose has been reduced via decontamination, were evaluated as 0.47±0.13, 0.51±0.13, and 0.58±0.08 (average±σ) when H{sup *}(10){sub out} <1.0 μSv h{sup -1}, 1.0 μSv h{sup -1} 2.0 μSv h{sup -1}, and 2.0 μSv h{sup -1}outdoors and 0.41±0.09 indoors, respectively, indicating RE was larger outdoors than indoors. Indoor dose is essential as most individuals spend a large portion of their time indoors. The difference between outdoors and indoors should be considered carefully in order to estimate residents’ exposure dose before their returning home.

  10. Daily indoor-to-outdoor temperature and humidity relationships: a sample across seasons and diverse climatic regions.

    Science.gov (United States)

    Nguyen, Jennifer L; Dockery, Douglas W

    2016-02-01

    The health consequences of heat and cold are usually evaluated based on associations with outdoor measurements collected at a nearby weather reporting station. However, people in the developed world spend little time outdoors, especially during extreme temperature events. We examined the association between indoor and outdoor temperature and humidity in a range of climates. We measured indoor temperature, apparent temperature, relative humidity, dew point, and specific humidity (a measure of moisture content in air) for one calendar year (2012) in a convenience sample of eight diverse locations ranging from the equatorial region (10 °N) to the Arctic (64 °N). We then compared the indoor conditions to outdoor values recorded at the nearest airport weather station. We found that the shape of the indoor-to-outdoor temperature and humidity relationships varied across seasons and locations. Indoor temperatures showed little variation across season and location. There was large variation in indoor relative humidity between seasons and between locations which was independent of outdoor airport measurements. On the other hand, indoor specific humidity, and to a lesser extent dew point, tracked with outdoor, airport measurements both seasonally and between climates, across a wide range of outdoor temperatures. These results suggest that, in general, outdoor measures of actual moisture content in air better capture indoor conditions than outdoor temperature and relative humidity. Therefore, in studies where water vapor is among the parameters of interest for examining weather-related health effects, outdoor measurements of actual moisture content can be more reliably used as a proxy for indoor exposure than the more commonly examined variables of temperature and relative humidity.

  11. New insight into the distribution pattern, levels, and risk diagnosis of FRs in indoor and outdoor air at low- and high-altitude zones of Pakistan: Implications for sources and exposure.

    Science.gov (United States)

    Khan, Muhammad Usman; Besis, Athanasios; Li, Jun; Zhang, Gan; Malik, Riffat Naseem

    2017-10-01

    Data regarding flame retardants (FRs) in indoor and outdoor air and their exposure to population are scarce and especially unknown in the case of Pakistan. The current study was designed to probe FR concentrations and distribution pattern in indoor and outdoor air at different altitudinal zones (DAZs) of Pakistan with special emphasis on their risk to the exposed population. In this study, passive air samplers for the purpose of FR deposition were deployed in indoor and outdoor air at the industrial, rural, and background/colder zones/sites. All the indoor and outdoor air samples collected from DAZs were analyzed for the target FRs (9.30-472.30 pg/m 3 ), showing a decreasing trend as follows: ∑NBFRs > ∑PBDEs > ∑DP. However, significant correlations among FRs in the indoor and outdoor air at DAZs signified a similar source of FR origin that is used in different consumer goods. Furthermore, air mass trajectories revealed that movement of air over industrial area sources influenced concentrations of FRs at rural sites. The FR concentrations, estimated daily intake (EDI) and the hazard quotient (HQ), were recorded to be higher in toddlers than those in adults. In addition, indoor air samples showed higher FR levels, EDI and HQ, than outdoor air samples. An elevated FR concentrations and their prevalent exposure risks were recorded in the industrial zones followed by rural and background zones. The HQ for BDE-47 and BDE-99 in the indoor and outdoor air samples at different industrial and rural sites were recorded to be >1 in toddlers and adults, this further warrants a health risk in the population. However, FR investigation in indoor and outdoor air samples will provide a baseline data in Pakistan to take further steps by the government and agencies for its implementations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Estimation of indoor and outdoor ratios of selected volatile organic compounds in Canada

    Science.gov (United States)

    Xu, Jing; Szyszkowicz, Mieczyslaw; Jovic, Branka; Cakmak, Sabit; Austin, Claire C.; Zhu, Jiping

    2016-09-01

    Indoor air and outdoor air concentration (I/O) ratio can be used to identify the origins of volatile organic compounds (VOCs). I/O ratios of 25 VOCs in Canada were estimated based on the data collected in various areas in Canada between September 2009 and December 2011. The indoor VOC data were extracted from the Canadian Health Measures Survey (CHMS). Outdoor VOC data were obtained from Canada's National Air Pollution Surveillance (NAPS) Network. The sampling locations covered nine areas in six provinces in Canada. Indoor air concentrations were found higher than outdoor air for all studied VOCs, except for carbon tetrachloride. Two different approaches were employed to estimate the I/O ratios; both approaches produced similar I/O values. The I/O ratios obtained from this study were similar to two other Canadian studies where indoor air and outdoor air of individual dwellings were measured. However, the I/O ratios found in Canada were higher than those in European cities and in two large USA cities, possibly due to the fact that the outdoor air concentrations recorded in the Canadian studies were lower. Possible source origins identified for the studied VOCs based on their I/O ratios were similar to those reported by others. In general, chlorinated hydrocarbons, short-chain (C5, C6) n-alkanes and benzene had significant outdoor sources, while long-chain (C10sbnd C12) n-alkanes, terpenes, naphthalene and styrene had significant indoor sources. The remaining VOCs had mixed indoor and outdoor sources.

  13. Risk factors for severe injury following indoor and outdoor falls in geriatric patients.

    Science.gov (United States)

    Kim, Sun Hyu

    2016-01-01

    This study was performed to examine the characteristics of indoor and outdoor falls in older patients and the factors related to severe injury in the emergency department (ED). In total, 26,515 patients fell indoors and 19,581 outdoors. The general and clinical characteristics were compared between the two groups and factors associated with severe injury following the falls were evaluated. Younger males fell more frequently outdoors than indoors. The common activities during outdoor falls were sports and leisure activities. Environmental hazards lead to more outdoor falls than indoor falls. Factors associated with severe injury after indoor falls were transport to the ED by public ambulance or from another medical facility rather than individual transportation, fall from stairs rather than fell over, and a head and neck injury rather than a lower extremity injury. Factors related to severe injury after outdoor falls were male sex, transport to the ED by public ambulance or from another medical facility or by another method rather than individual transportation, state employed, fall from stairs rather than fell over, head and neck or thorax or abdomen injury rather than a lower extremity injury. Transport to the ED by public ambulance or from another medical facility, and head and neck injury were risks for severe injury following indoor and outdoor falls in elderly subjects. Efforts to identify the risk factors for severe injury and for falling itself are important to prevent and reduce fall injuries in elderly subjects. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. Assessment of indoor and outdoor PM species at schools and residences in a high-altitude Ecuadorian urban center.

    Science.gov (United States)

    Raysoni, Amit U; Armijos, Rodrigo X; Weigel, M Margaret; Montoya, Teresa; Eschanique, Patricia; Racines, Marcia; Li, Wen-Whai

    2016-07-01

    An air monitoring campaign to assess children's environmental exposures in schools and residences, both indoors and outdoors, was conducted in 2010 in three low-income neighborhoods in Z1 (north), Z2 (central), and Z3 (southeast) zones of Quito, Ecuador - a major urban center of 2.2 million inhabitants situated 2850 m above sea level in a narrow mountainous basin. Z1 zone, located in northern Quito, historically experienced emissions from quarries and moderate traffic. Z2 zone was influenced by heavy traffic in contrast to Z3 zone which experienced low traffic densities. Weekly averages of PM samples were collected at schools (one in each zone) and residences (Z1 = 47, Z2 = 45, and Z3 = 41) every month, over a twelve-month period at the three zones. Indoor PM2.5 concentrations ranged from 10.6 ± 4.9 μg/m(3) (Z1 school) to 29.0 ± 30.5 μg/m(3) (Z1 residences) and outdoor PM2.5 concentrations varied from 10.9 ± 3.2 μg/m(3) (Z1 school) to 14.3 ± 10.1 μg/m(3) (Z2 residences), across the three zones. The lowest values for PM10-2.5 for indoor and outdoor microenvironments were recorded at Z2 school, 5.7 ± 2.8 μg/m(3) and 7.9 ± 2.2 μg/m(3), respectively. Outdoor school PM concentrations exhibited stronger associations with corresponding indoor values making them robust proxies for indoor exposures in naturally ventilated Quito public schools. Correlation analysis between the school and residential PM size fractions and the various pollutant and meteorological parameters from central ambient monitoring (CAM) sites suggested varying degrees of temporal relationship. Strong positive correlation was observed for outdoor PM2.5 at Z2 school and its corresponding CAM site (r = 0.77) suggesting common traffic related emissions. Spatial heterogeneity in PM2.5 concentrations between CAM network and sampled sites was assessed using Coefficient of Divergence (COD) analysis. COD values were lower when CAM sites were paired with outdoor

  15. Associations between the proportion of Salmonella seropositive slaughter pigs and the presence of herd level risk factors for introduction and transmission of Salmonella in 34 Danish organic, outdoor (non-organic) and indoor finishing-pig farms

    DEFF Research Database (Denmark)

    Zheng, D.M.; Bonde, Marianne; Sørensen, Jan Tind

    2007-01-01

    This paper evaluates the association between herd level risk factors for introduction and transmission of Salmonella in farms with three different production systems: organic, outdoor (non-organic) and indoor finishing-pig farms, and the presence of seropositive animals in the herds. Potential risk...... factors for Salmonella in the three pig production systems were identified through a literature review, and management information as well as serological data were collected in 34 pig farms: 11 organic farms, 12 outdoor farms, and 11 indoor farms. There were no general differences in the proportion...

  16. Indoor/outdoor relationships, sources and cancer risk assessment of NPAHs and OPAHs in PM2.5 at urban and suburban hotels in Jinan, China

    Science.gov (United States)

    Li, Yanyan; Yang, Lingxiao; Chen, Xiangfeng; Jiang, Pan; Gao, Ying; Zhang, Junmei; Yu, Hao; Wang, Wenxing

    2018-06-01

    Paired indoor and outdoor measurements of 16 NPAHs and 5 OPAHs in PM2.5 were conducted at urban and suburban sites during January 2016 in Jinan, China. The concentrations of both indoor and outdoor NPAHs and OPAHs were higher at the urban site compared with the suburban site. 9N-ANT (16-42%), 2+3N-FLA (15-51%), 2N-PYR (6-20%), and 1N-PYR (4-6%) were the dominant NPAHs at all sites, and 9-FO (61-81%) was the most abundant OPAHs. Solid fuel combustion, motor vehicle exhausts, and secondary generation were the main sources of the PAH derivatives in this study area. The I/O ratios of 90% of NPAHs and OPAHs at the first urban indoor site (abbreviated as URI1, Green Tree Inn) and the suburban indoor site (abbreviated as SUI, the Seven Star Hotel) were Hotel), the I/O ratios of 2- and 3-ring NPAHs and OPAHs were >1.00, which was likely due to cooking activities occurring near the measurement site. Measurements of outdoor 2+3N-FLA/1N-PYR revealed mainly primary emission at the urban site and secondary sources at the suburban site, the average ratios were 3.76 and 12.22, respectively. The average ratio of 2+3N-FLA/2N-PYR at all sites was 3.3, indicating that the OH-initiated reaction was the dominant secondary formation pathway. Nighttime ratios of 2+3N-FLA/1N-PYR were significantly higher than the daytime ratios at all sites. The difference was especially pronounced during heavily polluted conditions at the suburban site, which suggests that heavy pollution and nighttime conditions promote secondary production. Additionally, the cancer risk was highest in urban outdoor (abbreviated as URO) when the population expose to the level as the outdoor air in the urban. The risk suggested that adults may be at a higher cancer risk.

  17. Comparative Indoor and Outdoor Degradation of Organic Photovoltaic Cells via Inter-laboratory Collaboration

    DEFF Research Database (Denmark)

    Owens, Charles; Ferguson, Gretta Mae; Hermenau, Martin

    2016-01-01

    We report on the degradation of organic photovoltaic (OPV) cells in both indoor and outdoor environments. Eight different research groups contributed state of the art OPV cells to be studied at Pomona College. Power conversion efficiency and fill factor were determined from IV curves collected...... at regular intervals over six to eight months. Similarly prepared devices were measured indoors, outdoors, and after dark storage. Device architectures are compared. Cells kept indoors performed better than outdoors due to the lack of temperature and humidity extremes. Encapsulated cells performed better due...

  18. Prediction of Wind Environment and Indoor/Outdoor Relationships for PM2.5 in Different Building–Tree Grouping Patterns

    Directory of Open Access Journals (Sweden)

    Bo Hong

    2018-01-01

    Full Text Available Airflow behavior and indoor/outdoor PM2.5 dispersion in different building–tree grouping patterns depend significantly on the building–tree layouts and orientation towards the prevailing wind. By using a standard k-ε model and a revised generalized drift flux model, this study evaluated airflow fields and indoor/outdoor relationships for PM2.5 resulting from partly wind-induced natural ventilation in four hypothetical building–tree grouping patterns. Results showed that: (1 Patterns provide a variety of natural ventilation potential that relies on the wind influence, and buildings that deflect wind on the windward facade and separate airflow on the leeward facade have better ventilation potential; (2 Patterns where buildings and trees form a central space and a windward opening side towards the prevailing wind offer the best ventilation conditions; (3 Under the assumption that transported pollution sources are diluted through the inlet, the aerodynamics and deposition effects of trees cause the lower floors of a multi-storey building to be exposed to lower PM2.5 compared with upper floors, and lower indoor PM2.5 values were found close to the tree canopy; (4 Wind pressure differences across each flat showed a poor correlation (R2 = 0.059, with indoor PM2.5 concentrations; and (5 Patterns with the long facade of buildings and trees perpendicular to the prevailing wind have the lowest indoor PM2.5 concentrations.

  19. Radon level in China and elevated indoor exposure in carbon brick and cave dwellings

    International Nuclear Information System (INIS)

    Wang Zuoyuan

    1992-01-01

    A nation wide survey of Chinese houses was conducted to determine the average annual effective dose to Chinese population from exposure to radon and its daughter products. The indoor and outdoor concentrations of radon and its daughters were measured using scintillation flask, two filter and carbon canister methods, as well as modified Tsivoglou methods for Rn daughters. Average Rn concentrations are 26.2Bqm -3 and 13.5Bqm -3 for indoor and outdoor environment, respectively. Potential alpha energy concentration, indoor is 744 x 10 -10 Jm -3 , outdoor is 511 x 10 -10 Jm -3 . Equilibrium Factor of Rn daughters are 0.49 (indoor) and 0.61 (outdoor). Occupancy Factor is 0.77 and 0.23. Using appropriate conversion factors, the annual average effective dose to Chinese population is 0.967 mSv. And also, the indoor Rn concentration and gamma dose rate were surveyed in two rural Provinces: Gansu and Jianxi. The fact was found that lung cancer mortality of population lived in high Rn level dwellings is higher than in control groups. An epidemiological retrospective case-control study is recommended in houses with high Rn level. (author)

  20. Source Apportionment and Influencing Factor Analysis of Residential Indoor PM2.5 in Beijing

    Science.gov (United States)

    Yang, Yibing; Liu, Liu; Xu, Chunyu; Li, Na; Liu, Zhe; Wang, Qin; Xu, Dongqun

    2018-01-01

    In order to identify the sources of indoor PM2.5 and to check which factors influence the concentration of indoor PM2.5 and chemical elements, indoor concentrations of PM2.5 and its related elements in residential houses in Beijing were explored. Indoor and outdoor PM2.5 samples that were monitored continuously for one week were collected. Indoor and outdoor concentrations of PM2.5 and 15 elements (Al, As, Ca, Cd, Cu, Fe, K, Mg, Mn, Na, Pb, Se, Tl, V, Zn) were calculated and compared. The median indoor concentration of PM2.5 was 57.64 μg/m3. For elements in indoor PM2.5, Cd and As may be sensitive to indoor smoking, Zn, Ca and Al may be related to indoor sources other than smoking, Pb, V and Se may mainly come from outdoor. Five factors were extracted for indoor PM2.5 by factor analysis, explained 76.8% of total variance, outdoor sources contributed more than indoor sources. Multiple linear regression analysis for indoor PM2.5, Cd and Pb was performed. Indoor PM2.5 was influenced by factors including outdoor PM2.5, smoking during sampling, outdoor temperature and time of air conditioner use. Indoor Cd was affected by factors including smoking during sampling, outdoor Cd and building age. Indoor Pb concentration was associated with factors including outdoor Pb and time of window open per day, building age and RH. In conclusion, indoor PM2.5 mainly comes from outdoor sources, and the contributions of indoor sources also cannot be ignored. Factors associated indoor and outdoor air exchange can influence the concentrations of indoor PM2.5 and its constituents. PMID:29621164

  1. Photoenhanced uptakes of NO2 by indoor surfaces: A new HONO source

    Science.gov (United States)

    Gligorovski, S.; Bartolomei, V.; Soergel, M.; Gomez Alvarez, E.; Zetzsch, C.; Wortham, H.

    2012-12-01

    Nitrous acid (HONO) is a known household pollutant that can lead to human respiratory tract irritation. HONO acts as the nitrosating agent, e.g. by the formation of the so-called third-hand smoke after wall reactions of HONO with nicotine (1). HONO can be generated indoors directly during combustion processes or indirectly via heterogeneous NO2 reactions with adsorbed water on diverse surfaces (2). Recently a new source was identified as another path of HONO formation in the troposphere (3). Namely, the light-induced heterogeneous reaction of NO2 with adsorbed organics (known as photosensitizers) on various surfaces such as roads, buildings, rocks or plants leads to enhanced HONO production. The detected values of HONO indoors vary in the range between 2 and 25 parts per billion (ppb). However, like outdoors, the processes leading to HONO formation indoors are not completely understood (4). Indoor photolysis radiation sources include exterior sunlight (λ>350 nm) that enters typically through the windows and indoor illumination sources, i.e., rare gas/mercury fluorescent light bulbs and tungsten and tungsten/halogen light bulbs among others. The present work is showing the importance of indoor sources of HONO recently identified or postulated. We have tested a number of common household chemical agents commonly used for cleaning purposes or coatings of domestic surfaces to better identify different indoor HONO sources. We used a heterogeneous flow tube technique to test the HONO production potentials of these household chemical agents under different experimental conditions, namely with and without light and at different relative humidity levels and different NO2 concentrations. We report uptake kinetics measurements of the heterogeneous reaction of gas phase NO2 with lacquer and paint coated on the walls of the reactor. The flow tube was irradiated with four near-ultraviolet (UV) emitting lamps (range of wavelengths 300-420nm). We observed that the heterogeneous

  2. A sub-nationwide survey of outdoor and indoor 222Rn concentrations in China by passive method

    International Nuclear Information System (INIS)

    Jin Yihe; Ikebe, Y.; Iida, T.

    1996-01-01

    From Nov. 1988 to Mar. 1993, cooperated by China and Japan, a survey of outdoor and indoor 222 Rn concentrations in 10 cities which were highly populated in China was carried out by means of passive method. the annual mean of outdoor 222 Rn concentration in 10 cities was 8.8 Bq·m -3 . The highest of 13.5 Bq·m -3 was in Wuhan, the lowest of 3.3 Bq·m -3 was in Chongming Island of Shanghai; and there were no significant differences among the different years in the same areas. During the northwest wind seasons, about 50% of outdoor 222 Rn concentration in Taiwan was contributed by the airflow from the mainland. Typical apartment houses and offices built of brick and concrete were also surveyed for indoor 222 Rn concentration. The annual mean of indoor 222 Rn concentration in the 10 cities was 19.5 Bq·m - 3. The highest of 33.9 Bq·m -3 was observed in Guiyang, the lowest of 9.0 Bq·m -3 was observed in Chongming Island of Shanghai. The outdoor and indoor 222 Rn concentrations showed a clear seasonal pattern with the minimum in summer and the maximum in winter. And they also showed a clear geographic distribution tendency; they were higher in inland than in seashores, and higher in the south than in the north. The ratios of indoor to outdoor 222 Rn concentrations were from 1.1 to 4.6. The annual effective dose equivalents resulting from outdoor and indoor 222 Rn concentrations amounted to about 0.64 mSv·a -1 . The highest was in Guiyang, and the lowest was in Nantong, being 1.12 and 0.39 mSv·a -1 , respectively

  3. The effect of proximity to major roads on indoor air quality in typical Australian dwellings

    Science.gov (United States)

    Lawson, Sarah J.; Galbally, Ian E.; Powell, Jennifer C.; Keywood, Melita D.; Molloy, Suzie B.; Cheng, Min; Selleck, Paul W.

    2011-04-01

    An Indoor Air Quality Study of residential dwellings was carried out in Melbourne, Australia, and a subset of the data was analysed to investigate the effect of proximity to major roads on indoor air quality (IAQ). Seven-day measurements of PM 10, NO 2, benzene, toluene, ethylbenzene and xylenes, along with continuous CO and PM 2.5 measurements were utilised. The measurements were made indoors and outdoors in 27 dwellings; 15 Near Road (300 m from a major road). Dwellings were sampled for one week each in Winter/Spring 2008 and Summer/Autumn 2009, over an eight month period. Analysis of 7-day measurements showed that NO 2 and toluene were elevated at the 5% significance level both indoors and outdoors at Near Road Dwellings compared to Far Road Dwellings. Indoor/Outdoor (I/O) ratios of NO 2 and toluene were not significantly different between Near and Far Road dwellings giving no evidence of any anomalous dominant indoor source for NO 2 and toluene in Near Road dwellings. Indoor NO 2 was significantly correlated to gas stovetop and oven use in both Near and Far Road dwellings. In the absence of gas cooking, indoor NO 2 was elevated in Near Road dwellings relative to Far Road dwellings by approximately 4 ppb and this can be attributed to infiltration of outdoor air. I/O ratios for NO 2 were 2 indicating that indoor sources dominate with minor contribution from outdoors. Hence the relative contribution of roadways to indoor NO 2 is potentially greater than the relative contribution of roadways to indoor toluene. Findings elsewhere suggest that a similar outdoor enhancement of traffic related NO 2 (˜5 ppb) increases risk of lung cancer and childhood asthma ( Brauer et al., 2000; Nyberg et al., 2000). A simple conceptual model indicated spatial and temporal variance in the concentrations was the biggest limitation in detecting roadway influence outside Near Road dwellings for PM 10, PM 2.5 and NO 2 while measurement uncertainty was also important for CO.

  4. Health effects from indoor and outdoor exposure to fine particulate matter in life cycle impact assessment

    DEFF Research Database (Denmark)

    Fantke, Peter; McKone, T.E.; Jolliet, Olivier

    2016-01-01

    Exposure to fine particulate matter (PM2.5) pollution is a major contributor to human disease burden as continuously shown in the Global Burden of Disease study series. Exposures to PM2.5 concentration outdoors and indoors contribute almost equally to this burden. Despite the importance, health...... impacts from exposure to PM2.5 are often excluded from life cycle impact assessment (LCIA) characterization profiles. This is in large part because of the lack of well-vetted harmonized guidance about how to consistently assess the exposures and impacts of indoor and outdoor emissions of PM2.5 and its...... precursors. We present a framework for calculating characterization factors for indoor and outdoor emissions of primary PM2.5 and secondary PM2.5 precursors, and a roadmap for further refining this modelling framework for operational use in LCIA. The framework was developed over the last three years...

  5. Characterization of PAHs and metals in indoor/outdoor PM10/PM2.5/PM1 in a retirement home and a school dormitory.

    Science.gov (United States)

    Hassanvand, Mohammad Sadegh; Naddafi, Kazem; Faridi, Sasan; Nabizadeh, Ramin; Sowlat, Mohammad Hossein; Momeniha, Fatemeh; Gholampour, Akbar; Arhami, Mohammad; Kashani, Homa; Zare, Ahad; Niazi, Sadegh; Rastkari, Noushin; Nazmara, Shahrokh; Ghani, Maryam; Yunesian, Masud

    2015-09-15

    In the present work, we investigated the characteristics of polycyclic aromatic hydrocarbons (PAHs) and metal(loid)s in indoor/outdoor PM10, PM2.5, and PM1 in a retirement home and a school dormitory in Tehran from May 2012 to May 2013. The results indicated that the annual levels of indoor and outdoor PM10 and PM2.5 were much higher than the guidelines issued by the World Health Organization (WHO). The most abundant detected metal(loid)s in PM were Si, Fe, Zn, Al, and Pb. We found higher percentages of metal(loid)s in smaller size fractions of PM. Additionally, the results showed that the total PAHs (ƩPAHs) bound to PM were predominantly (83-88%) found in PM2.5, which can penetrate deep into the alveolar regions of the lungs. In general, carcinogenic PAHs accounted for 40-47% of the total PAHs concentrations; furthermore, the smaller the particle size, the higher the percentage of carcinogenic PAHs. The percentages of trace metal(loid)s and carcinogenic PAHs in PM2.5 mass were almost twice as high as those in PM10. This can most likely be responsible for the fact that PM2.5 can cause more adverse health effects than PM10 can. The average BaP-equivalent carcinogenic (BaP-TEQ) levels both indoors and outdoors considerably exceeded the maximum permissible risk level of 1 ng/m(3) of BaP. The enrichment factors and diagnostic ratios indicated that combustion-related anthropogenic sources, such as gasoline- and diesel-fueled vehicles as well as natural gas combustion, were the major sources of PAHs and trace metal(loid)s bound to PM. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. A note on the relationship between outdoor and indoor exposure integrals for air pollution of outdoor origin

    International Nuclear Information System (INIS)

    Gjoerup, H.L.; Roed, J.

    1980-05-01

    Beryllium-7 created by cosmic radiation has been used as a tracer in preliminary measurements designed to enable an estimation of the ratio between outdoor and indoor exposure integrals for aerosols of outdoor origin, with special reference to the reduction in inhalation dose that can be achieved by staying indoors during reactor accidents. Earlier investigations relevant to this problem are reviewed. It is concluded that the reduction is inhalation dose offered by an average Danish house is roughly one order of magnitude. (author)

  7. Impact of Middle Eastern dust storms on indoor and outdoor composition of bioaerosol

    Science.gov (United States)

    Soleimani, Zahra; Goudarzi, Gholamreza; Sorooshian, Armin; Marzouni, Mohammad Bagherian; Maleki, Heidar

    2016-08-01

    The presence of microbes in airborne aerosol particles, especially dust, is a major public health concern in desert regions. This study is the first of its kind to examine the effect of dust storms on indoor and outdoor microbial air quality at a hospital on the western side of Iran (city of Ahvaz), which is notorious for being highly vulnerable to dust emissions. Air samples were collected inside and outside of the hospital environment for six months, with the unique advantage of this study being that the region and duration of measurements allow for a clear comparison between dusty and normal days. On normal days, the average concentrations (outdoor/indoor) of bacteria and fungi were 423/329 cfu m-3 and 596/386 cfu m-3, respectively, which increased to 1257/406 cfu m-3 and 1116/550 cfu m-3 on dust event days. Indoor/Outdoor ratios for bacteria and fungi are lower on dust event days (0.26-0.60) versus normal days (0.44-0.95). Bacillus spp., Micrococcus spp., Streptomyces spp., and Staphylococcus spp. were the dominant bacteria both indoors and outdoors on normal and dust event days. Gram positive bacteria exhibited higher concentrations than Gram negative bacteria in both outdoor and indoor air samples as well as during both normal and dust event days. The data suggest that Gram positive bacteria are more resistant to undesirable outdoor conditions (e.g., high incident solar radiation) as compared to Gram negative ones. These results have implications for other populated arid regions where more stringent control of indoor air quality can greatly benefit public health.

  8. Daily variation of the radon concentration indoors and outdoors and the influence of meteorological parameters

    International Nuclear Information System (INIS)

    Porstendoerfer, J.; Butterweck, G.; Reineking, A.

    1994-01-01

    Series of continuous radon measurements in the open atmosphere and in a dwelling, including the parallel measurement of meteorological parameters, were performed over a period of several weeks. The radon concentration in indoor and outdoor air depends on meteorological conditions. In the open atmosphere the radon concentration varies between 1 and 100 Bq m -3 , depending on weather conditions and time of day. During time periods of low turbulent air exchange (high pressure weather with clear night sky), especially in the night and early morning hours (night inversion layer), the diurnal variation of the radon concentration showed a pronounced maximum. Cloudy and windy weather conditions yield a small diurnal variation of the radon concentration. Indoors, the average level and the diurnal variation of the indoor radon concentration is also influenced by meteorological conditions. The measurements are consistent with a dependence of indoor radon concentrations on indoor-outdoor pressure differences. 11 refs., 4 figs

  9. Vitamin D-binding protein, vitamin D status and serum bioavailable 25(OH)D of young Asian Indian males working in outdoor and indoor environments.

    Science.gov (United States)

    Goswami, Ravinder; Saha, Soma; Sreenivas, Vishnubhatla; Singh, Namrata; Lakshmy, Ramakrishnan

    2017-03-01

    Urban Asian Indians generally have low serum 25(OH)D. Information on serum bioavailable 25(OH)D and the effect of prolonged sun-exposure in them is not known. We assessed serum 25(OH)D and bioavailable 25(OH)D in males with varying durations of sun-exposure in Delhi during August-September. Serum 25(OH)D, vitamin D-binding protein (DBP), bioavailable 25(OH)D, free 25(OH)D index, iPTH, ionized calcium and sun-index were assessed in outdoor, mixed outdoor-indoor and indoor workers (n = 88, 32 and 74, respectively). The mean sun-index (12.0 ± 6.25, 4.3 ± 2.20 and 0.7 ± 0.62, respectively; P < 0.001) was highest outdoors and lowest indoors. Serum 25(OH)D (29.0 ± 8.61, 19.1 ± 5.73 and 10.9 ± 4.19 ng/ml, respectively; P < 0.001), bioavailable 25(OH)D and free 25(OH)D index were maximum in outdoor workers followed by mixed-exposure and indoor workers. Their mean serum DBP levels (241.2 ± 88.77, 239.3 ± 83.40 and 216.6 ± 63.93 µg/ml, respectively; P = 0.12) were comparable. Mean serum iPTH was significantly lower in outdoor than indoor workers and showed inverse correlations with serum 25(OH)D, bioavailable 25(OH)D and free 25(OH)D index (r = -0.401, -0.269 and -0.236, respectively; P < 0.001 in all). Daily dietary-calorie intake was higher and calcium lower in outdoor than indoor workers. On regression analysis, sun-exposure was the only significant variable, increasing serum 25(OH)D by 2.03 ng/ml per hour of sun-exposure (95 % confidence interval 1.77-2.28; P < 0.001). Outdoor workers with prolonged sun-exposure were vitamin D-sufficient, with higher serum bioavailable 25(OH)D than the indoor workers during summer. Use of serum DBP levels did not affect the interpretation of their vitamin D status.

  10. Indoor radon levels in selected hot spring hotels in Guangdong, China.

    Science.gov (United States)

    Song, Gang; Zhang, Boyou; Wang, Xinming; Gong, Jingping; Chan, Daniel; Bernett, John; Lee, S C

    2005-03-01

    Guangdong is one of the provinces that have most hot springs in China, and many hotels have been set up near hot springs, with spring water introduced into the bath inside each hotel room for hot spring bathing to attract tourists. In the present study, we measured radon in indoor and outdoor air, as well as in hot spring waters, in four hot spring hotels in Guangdong by using NR-667A (III) continuous radon detector. Radon concentrations ranged 53.4-292.5 Bq L(-1) in the hot spring water and 17.2-190.9 Bq m(-3) in outdoor air. Soil gas intrusion, indoor hot spring water use and inefficient ventilation all contributed to the elevated indoor radon levels in the hotel rooms. From the variation of radon levels in closed unoccupied hotel rooms, soil gas intrusion was found to be a very important source of indoor radon in hotel rooms with floors in contact with soils. When there was spring water bathing in the bathes, average radon levels were 10.9-813% higher in the hotel rooms and 13.8-489% higher in bathes compared to their corresponding average levels when there was no spring water use. Spring water use in the hotel rooms had radon transfer coefficients from 1.6x10(-4) to 5.0x10(-3). Radon in some hotel rooms maintained in concentrations much higher than guideline levels might thus have potential health risks to the hotel workers, and technical and management measures should be taken to lower their exposure of radon through inhalation.

  11. Indoor radon levels in selected hot spring hotels in Guangdong, China

    International Nuclear Information System (INIS)

    Song Gang; Zhang Boyou; Wang Xinming; Gong Jingping; Chan, Daniel; Bernett, John; Lee, S.C.

    2005-01-01

    Guangdong is one of the provinces that have most hot springs in China, and many hotels have been set up near hot springs, with spring water introduced into the bath inside each hotel room for hot spring bathing to attract tourists. In the present study, we measured radon in indoor and outdoor air, as well as in hot spring waters, in four hot spring hotels in Guangdong by using NR-667A (III) continuous radon detector. Radon concentrations ranged 53.4-292.5 Bq L -1 in the hot spring water and 17.2-190.9 Bq m -3 in outdoor air. Soil gas intrusion, indoor hot spring water use and inefficient ventilation all contributed to the elevated indoor radon levels in the hotel rooms. From the variation of radon levels in closed unoccupied hotel rooms, soil gas intrusion was found to be a very important source of indoor radon in hotel rooms with floors in contact with soils. When there was spring water bathing in the bathes, average radon levels were 10.9-813% higher in the hotel rooms and 13.8-489% higher in bathes compared to their corresponding average levels when there was no spring water use. Spring water use in the hotel rooms had radon transfer coefficients from 1.6x10 -4 to 5.0x10 -3 . Radon in some hotel rooms maintained in concentrations much higher than guideline levels might thus have potential health risks to the hotel workers, and technical and management measures should be taken to lower their exposure of radon through inhalation

  12. Comparative Indoor and Outdoor Degradation of Organic Photovoltaic Cells via Inter-laboratory Collaboration

    OpenAIRE

    Owens, Charles; Ferguson, Gretta; Hermenau, Martin; Voroshazi, Eszter; Galagan, Yulia; Zimmermann, Birger; Rösch, Roland; Angmo, Dechan; Teran-Escobar, Gerardo; Uhrich, Christian; Andriessen, Ronn; Hoppe, Harald; Würfel, Uli; Lira-Cantu, Monica; Krebs, Frederik

    2015-01-01

    We report on the degradation of organic photovoltaic (OPV) cells in both indoor and outdoor environments. Eight different research groups contributed state of the art OPV cells to be studied at Pomona College. Power conversion efficiency and fill factor were determined from IV curves collected at regular intervals over six to eight months. Similarly prepared devices were measured indoors, outdoors, and after dark storage. Device architectures are compared. Cells kept indoors performed better ...

  13. Characterization of indoor and outdoor pool fires with active calorimetry

    International Nuclear Information System (INIS)

    Koski, J.A.; Gill, W.; Gritzo, L.A.; Kent, L.A.; Wix, S.D.

    1994-01-01

    A water cooled, 1 m x 1 m, vertical calorimeter panel has been used in conjunction with other fire diagnostics to characterize a 6 m x 6 m outdoor and three 3 m x 3 m indoor JP-4 pool fires. Measurements reported include calorimeter surface heat flux and surface temperatures, flame temperatures, and gas flow velocities in the fire. From the data, effective radiative absorption coefficients for various zones in the fires have been estimated. The outdoor test was conducted at Sandia's Coyote Canyon test facility, while indoor tests were conducted at the indoor SMokE Reduction Facility (SMERF) at the same location. The measurements provide data useful in calibrating simple analytic fire models intended for the analysis of packages containing hazardous materials

  14. High blood pressure and long-term exposure to indoor noise and air pollution from road traffic.

    Science.gov (United States)

    Foraster, Maria; Künzli, Nino; Aguilera, Inmaculada; Rivera, Marcela; Agis, David; Vila, Joan; Bouso, Laura; Deltell, Alexandre; Marrugat, Jaume; Ramos, Rafel; Sunyer, Jordi; Elosua, Roberto; Basagaña, Xavier

    2014-11-01

    Traffic noise has been associated with prevalence of hypertension, but reports are inconsistent for blood pressure (BP). To ascertain noise effects and to disentangle them from those suspected to be from traffic-related air pollution, it may be essential to estimate people's noise exposure indoors in bedrooms. We analyzed associations between long-term exposure to indoor traffic noise in bedrooms and prevalent hypertension and systolic (SBP) and diastolic (DBP) BP, considering long-term exposure to outdoor nitrogen dioxide (NO2). We evaluated 1,926 cohort participants at baseline (years 2003-2006; Girona, Spain). Outdoor annual average levels of nighttime traffic noise (Lnight) and NO2 were estimated at postal addresses with a detailed traffic noise model and a land-use regression model, respectively. Individual indoor traffic Lnight levels were derived from outdoor Lnight with application of insulations provided by reported noise-reducing factors. We assessed associations for hypertension and BP with multi-exposure logistic and linear regression models, respectively. Median levels were 27.1 dB(A) (indoor Lnight), 56.7 dB(A) (outdoor Lnight), and 26.8 μg/m3 (NO2). Spearman correlations between outdoor and indoor Lnight with NO2 were 0.75 and 0.23, respectively. Indoor Lnight was associated both with hypertension (OR = 1.06; 95% CI: 0.99, 1.13) and SBP (β = 0.72; 95% CI: 0.29, 1.15) per 5 dB(A); and NO2 was associated with hypertension (OR = 1.16; 95% CI: 0.99, 1.36), SBP (β = 1.23; 95% CI: 0.21, 2.25), and DBP (β⊇= 0.56; 95% CI: -0.03, 1.14) per 10 μg/m3. In the outdoor noise model, Lnight was associated only with hypertension and NO2 with BP only. The indoor noise-SBP association was stronger and statistically significant with a threshold at 30 dB(A). Long-term exposure to indoor traffic noise was associated with prevalent hypertension and SBP, independently of NO2. Associations were less consistent for outdoor traffic Lnight and likely affected by

  15. Low VHF Channel Measurements and Simulations in Indoor and Outdoor Scenarios

    Science.gov (United States)

    2015-05-01

    Transactions on. 2002;50(5):591-599. 22. Nerguizian C, Despins C, Affes S, Djadel M. Radio-channel characterization of an underground mine at 2.4 ghz...INTENTIONALLY LEFT BLANK. viii 1. Introduction Reliable wireless communication is of paramount importance for many important civilian and military...report, we study near-ground, wireless channel modeling in the lower VHF band for indoor and indoor/outdoor scenarios, drawing from extensive propagation

  16. The effect of farrowing environment and previous experience on the maternal behaviour of sows in indoor pens and outdoor huts.

    Science.gov (United States)

    Wülbers-Mindermann, M; Berg, C; Illmann, G; Baulain, U; Algers, B

    2015-04-01

    Outdoor farrowing huts facilitate a less restricted maternal behaviour in sows compared with sows kept indoors in farrowing pens. The aim of our study was to investigate whether there are behavioural differences between primiparous sows kept outdoors in farrowing huts and indoors in pens, and whether the maternal behaviour during the second parity, when all sows were kept outdoors in farrowing huts, would differ between sows that have experienced the indoor or the outdoor environment, respectively, during their first parturition. A total of 26 Yorkshire×Swedish Landrace sows were studied. Of these, 11 sows were housed outdoors in farrowing huts during both parturitions (group=OUTOUT). The other 15 sows were kept indoors in a barn with single farrowing pens during their first parturition. During their second parturition, sows were kept outdoors in farrowing huts (group=INOUT). The behaviour was video recorded from 2 h prepartum to 48 h postpartum. The sows' responsiveness to playbacks of a piglet's screams was tested on days 2 to 3 postpartum. Parity 1: during the last 2 h prepartum, OUTOUT sows had a higher proportion of observations in the sternal lying position (Pbehavioural differences between INOUT and OUTOUT sows. In conclusion, it is not problematic for a second parity sow with initial maternal experience from an indoor farrowing pen to be kept outdoors in farrowing huts during its following farrowing.

  17. Indoor and outdoor particulate matter in primary school classrooms with fan-assisted natural ventilation in Singapore.

    Science.gov (United States)

    Chen, Ailu; Gall, Elliott T; Chang, Victor W C

    2016-09-01

    We conducted multiday continuous monitoring of indoor and outdoor particulate matter (PM) in classrooms with fan-assisted natural ventilation (NV) at five primary schools in Singapore. We monitored size-resolved number concentration of PM with diameter 0.3-10 μm at all schools and alveolar deposited surface area concentrations of PM with diameter 0.01-1.0 μm (SA0.01-1.0) at two schools. Results show that, during the monitoring period, schools closer to expressways and in the downtown area had 2-3 times higher outdoor PM0.3-1.0 number concentrations than schools located in suburban areas. Average indoor SA0.01-1.0 was 115-118 μm(2) cm(-3) during periods of occupancy and 72-87 μm(2) cm(-3) during unoccupied periods. There were close indoor and outdoor correlations for fine PM during both occupied and unoccupied periods (Pearson's r = 0.84-1.0) while the correlations for coarse PM were weak during the occupied periods (r = 0.13-0.74). Across all the schools, the size-resolved indoor/outdoor PM ratios (I/O ratios) were 0.81 to 1.58 and 0.61 to 0.95 during occupied and unoccupied periods, respectively, and average infiltration factors were 0.64 to 0.94. Average PM net emission rates, calculated during periods of occupancy in the classrooms, were lower than or in the lower range of emission rates reported in the literature. This study also reveals that indoor fine and submicron PM predominantly come from outdoor sources, while indoor sources associated with occupancy may be important for coarse PM even when the classrooms have high air exchange rates.

  18. Indoor and outdoor sources of size-resolved mass concentration of particulate matter in a school gym-implications for exposure of exercising children.

    Science.gov (United States)

    Braniš, Martin; Safránek, Jiří; Hytychová, Adéla

    2011-05-01

    It has been noticed many times that schools are buildings with high levels of particulate matter concentrations. Several authors documented that concentrations of particulate matter in indoor school microenvironments exceed limits recommended by WHO namely when school buildings are situated near major roads with high traffic densities. In addition, exercise under conditions of high particulate concentrations may increase the adverse health effects, as the total particle deposition increases in proportion to minute ventilation, and the deposition fraction nearly doubles from rest to intense exercise. Mass concentrations of size-segregated aerosol were measured simultaneously in an elementary school gym and an adjacent outdoor site in the central part of Prague by two pairs of collocated aerosol monitors-a fast responding photometer DusTrak and a five stage cascade impactor. To encompass seasonal and annual differences, 89 days of measurements were performed during ten campaigns between 2005 and 2009. The average (all campaigns) outdoor concentration of PM(2.5) (28.3 μg m(-3)) measured by the cascade impactors was higher than the indoor value (22.3 μg m(-3)) and the corresponding average from the nearest fixed site monitor (23.6 μg m(-3)). Indoor and outdoor PM(2.5) concentrations exceeded the WHO recommended 24-h limit in 42% and 49% of the days measured, respectively. The correlation coefficient (r) between corresponding outdoor and indoor aerosol sizes increased with decreasing aerodynamic diameter of the collected particles (r = 0.32-0.87), suggesting a higher infiltration rate of fine and quasi-ultrafine particles. Principal component analysis revealed five factors explaining more than 82% of the data variability. The first two factors reflected a close association between outdoor and indoor fine and quasi-ultrafine particles confirming the hypothesis of high infiltration rate of particles from outdoors. The third factor indicated that human

  19. Chemical Characterization of the Indoor Air Quality of a University Hospital: Penetration of Outdoor Air Pollutants.

    Science.gov (United States)

    Scheepers, Paul T J; Van Wel, Luuk; Beckmann, Gwendolyn; Anzion, Rob B M

    2017-05-08

    For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ). The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two outdoor locations and source samples were collected from a helicopter and an emergency power supply. Volatile organic compounds (VOC), acrolein, formaldehyde, nitrogen dioxide (NO₂), respirable particulate matter (PM-4.0 and PM-2.5) and their respective benz(a)pyrene contents were determined over a period of two weeks. Time-weighted average concentrations of NO₂ (4.9-17.4 μg/m³) and formaldehyde (2.5-6.4 μg/m³) were similar on all indoor and outdoor locations. The median concentration VOC in indoor air was 119 μg/m³ (range: 33.1-2450 μg/m³) and was fivefold higher in laboratories (316 μg/m³) compared to offices (57.0 μg/m³). PM-4.0 and benzo(a)pyrene concentration were lower in buildings serviced by a >99.95% efficiency particle filter, compared to buildings using a standard 80-90% efficiency filter ( p engines to any of the IAQ parameters measured in this study. Chemical IAQ was primarily driven by known indoor sources and activities.

  20. [Indoor air pollution in southeast Santiago, Chile].

    Science.gov (United States)

    Pino, P; Oyarzún, M; Walter, T; von Baer, D; Romieu, I

    1998-04-01

    Indoor air pollution could play an important role in the susceptibility to respiratory diseases of vulnerable individuals, such as elders and infants. To evaluate indoor air pollution in a low income population of South East Santiago. A domiciliary survey of contaminant sources was carried out in the bouses of a cohort of 522 children less than one year old. Using a case-control design, 121 children consulting for respiratory diseases were considered as cases and 131 healthy infants of the same age and sex were considered as controls. In the houses of both groups, active monitors for particulate matter (PM10) and passive monitors for NO2 were installed. Forty two percent of fathers and 30% of mothers were smokers, and in two thirds of the families there was at least one smoker. Eighty five percent used portable heaters in winter. Of these, 77% used kerosene as fuel. Only 27% had water heating appliances. The rest heated water on the kitchen store or on bonfires. Most kitchen stoves used liquid gas as fuel. Twenty four hour PM10 was 109 +/- 3.2 micrograms/m3. Mean indoor and outdoor NO2 in 24 h was 108 +/- 76.3 and 84 +/- 53.6 micrograms/m3 respectively. Indoor NO2 levels were related to the use of heating devices and smoking. No differences in PM10 and NO2 levels were observed between cases and controls. There is a clear relationship between indoor pollution and contaminating sources. Indoor NO2 levels are higher than outdoors.

  1. A nationwide survey of radon concentration in Japan. Indoor, outdoor and workplace

    International Nuclear Information System (INIS)

    Sanada, Tetsuya; Oikawa, Shinji; Kanno, Nobuyuki; Abukawa, Johji; Higuchi, Hideo

    2004-01-01

    The nationwide indoor, outdoor and workplace radon concentrations were surveyed in Japan. These surveys were conducted to estimate the natural radiation dose due to radon and its progeny for the general public. The radon concentration was measured using passive type radon monitor. The number of radon monitors were installed at indoor, outdoor and workplace for 940 houses, 705 points and 705 sites, respectively. The radon concentration was measured for one year at each measurement site. Annual mean radon concentration was obtained from four quarters measurements of 47 prefectures in Japan. The nationwide indoor, outdoor and workplace annual mean radon concentration were 15.5 Bq m -3 , 6.1 Bq m -3 and 20.8 Bq m -3 , respectively. Their radon concentration shows approximately a logarithmic normal distribution. Workplace showed relatively high radon concentration compared with other environments, may be due to construction materials and low ventilation rate. The indoor radon concentration found to be seasonal variation and architectural dependences. Seasonal variation and regional distribution of outdoor radon concentration was also observed. From the results of these radon surveys, the annual effective dose to the general public due to radon and its progeny was estimated to be 0.49 mSv y -1 in Japan. (author)

  2. Indoor radon levels in selected hot spring hotels in Guangdong, China

    Energy Technology Data Exchange (ETDEWEB)

    Song Gang [Guangzhou Institute of Geochemistry, Chinese Academy of Science, Guangzhou 510640 (China); Zhang Boyou [Guangzhou Institute of Geochemistry, Chinese Academy of Science, Guangzhou 510640 (China); Wang Xinming [Guangzhou Institute of Geochemistry, Chinese Academy of Science, Guangzhou 510640 (China)]. E-mail: wangxm@gig.ac.cn; Gong Jingping [Guangzhou Institute of Geochemistry, Chinese Academy of Science, Guangzhou 510640 (China); Chan, Daniel [Department of Building Services Engineering, Hong Kong Polytechnic University, Hong Kong (China); Bernett, John [Department of Building Services Engineering, Hong Kong Polytechnic University, Hong Kong (China); Lee, S.C. [Department of Civil and Structural Engineering, Hong Kong Polytechnic University, Hong Kong (China)

    2005-03-01

    Guangdong is one of the provinces that have most hot springs in China, and many hotels have been set up near hot springs, with spring water introduced into the bath inside each hotel room for hot spring bathing to attract tourists. In the present study, we measured radon in indoor and outdoor air, as well as in hot spring waters, in four hot spring hotels in Guangdong by using NR-667A (III) continuous radon detector. Radon concentrations ranged 53.4-292.5 Bq L{sup -1} in the hot spring water and 17.2-190.9 Bq m{sup -3} in outdoor air. Soil gas intrusion, indoor hot spring water use and inefficient ventilation all contributed to the elevated indoor radon levels in the hotel rooms. From the variation of radon levels in closed unoccupied hotel rooms, soil gas intrusion was found to be a very important source of indoor radon in hotel rooms with floors in contact with soils. When there was spring water bathing in the bathes, average radon levels were 10.9-813% higher in the hotel rooms and 13.8-489% higher in bathes compared to their corresponding average levels when there was no spring water use. Spring water use in the hotel rooms had radon transfer coefficients from 1.6x10{sup -4} to 5.0x10{sup -3}. Radon in some hotel rooms maintained in concentrations much higher than guideline levels might thus have potential health risks to the hotel workers, and technical and management measures should be taken to lower their exposure of radon through inhalation.

  3. wayGoo: a platform for geolocating and managing indoor and outdoor spaces

    Science.gov (United States)

    Thomopoulos, Stelios C. A.; Karafylli, Christina; Karafylli, Maria; Motos, Dionysis; Lampropoulos, Vassilis; Dimitros, Kostantinos; Margonis, Christos

    2016-05-01

    wayGoo2 is a platform for Geolocating and Managing indoor and outdoor spaces and content with multidimensional indoor and outdoor Navigation and Guidance. Its main components are a Geographic Information System, a back-end server, front-end applications and a web-based Content Management System (CMS). It constitutes a fully integrated 2D/3D space and content management system that creates a repository that consists of a database, content components and administrative data. wayGoo can connect to any third party database and event management data-source. The platform is secure as the data is only available through a Restful web service using https security protocol in conjunction with an API key used for authentication. To enhance users experience, wayGoo makes the content available by extracting components out of the repository and constructing targeted applications. The wayGoo platform supports geo-referencing of indoor and outdoor information and use of metadata. It also allows the use of existing information such as maps and databases. The platform enables planning through integration of content that is connected either spatially, temporally or contextually, and provides immediate access to all spatial data through interfaces and interactive 2D and 3D representations. wayGoo constitutes a mean to document and preserve assets through computerized techniques and provides a system that enhances the protection of your space, people and guests when combined with wayGoo notification and alert system. It constitutes a strong marketing tool providing staff and visitors with an immersive tool for navigation in indoor spaces and allowing users to organize their agenda and to discover events through wayGoo event scheduler and recommendation system. Furthermore, the wayGoo platform can be used in Security applications and event management, e.g. CBRNE incidents, man-made and natural disasters, etc., to document and geolocate information and sensor data (off line and real time

  4. Factors controlling indoor radon levels. Annual report, June 1983-May 1984

    International Nuclear Information System (INIS)

    Harley, N.H.

    1984-01-01

    The factors which contribute to indoor radon levels were investigated. Soil moisture content appears to be such a factor and influences indoor radon levels in a subtle way. The single family dwelling studied here is a typical suburban home, with a full basement, two living levels and a full attic. Seasonal data for 1981 to 1983 are shown by hour (about 90 hours in each average) for the basement, first floor and outdoors. A twenty-five story, 225 apartment, high rise building has been under study for about the same time interval. The apartment has five rooms, and is on the 24th floor. Continuous monitors are located in a work room and outdoors on a terrace. Data are available from the summer of 1981. 2 references, 12 figures, 9 tables

  5. Indoor/outdoor of PM10 relationships and its water-soluble ions composition in selected primary schools in Malaysia

    Science.gov (United States)

    Mohamad, Noorlin; Latif, Mohd Talib

    2013-11-01

    Measurements of PM10 and water-soluble ions were carried out on indoor and outdoor PM10 (particles > 10 μm in aerodynamic diameter) aerosols sampled at selected primary schools of Kuala Lumpur (S1) and Putrajaya (S2), respectively. Samples were collected using a low volume sampler on Teflon filters. The water-soluble ions chloride (Cl-), nitrate (NO3-), sulfate (SO42-), calcium (Ca2+), magnesium (Mg2+), sodium (Na+), potassium (K+) and ammonium (NH4+) was analyzed using ion chromatography. The results showed that the indoor PM10 mass concentrations in S1 and S2 were 96.6 and 69.5 μg/m3, while the outdoor PM10 mass concentrations were 80.1 and 85.2 μg/m3, respectively. This indicated that NO3- were the most dominant ions, followed by SO42-, Ca2+, K+ and Na+, while Cl-, Mg2+ and Na+ were present at low concentrations. Pearson's correlation test applied to all the data showed high correlation between SO42- and NO3-, indicating a common anthropogenic origin. In addition, the correlations between Na+ and Ca2+ indicated crustal origins that significantly contributed to human exposure.

  6. Comparative Indoor and Outdoor Degradation of Organic Photovoltaic Cells via Inter-laboratory Collaboration

    Directory of Open Access Journals (Sweden)

    Charles Owens

    2015-12-01

    Full Text Available We report on the degradation of organic photovoltaic (OPV cells in both indoor and outdoor environments. Eight different research groups contributed state of the art OPV cells to be studied at Pomona College. Power conversion efficiency and fill factor were determined from IV curves collected at regular intervals over six to eight months. Similarly prepared devices were measured indoors, outdoors, and after dark storage. Device architectures are compared. Cells kept indoors performed better than outdoors due to the lack of temperature and humidity extremes. Encapsulated cells performed better due to the minimal oxidation. Some devices showed steady aging but many failed catastrophically due to corrosion of electrodes not active device layers. Degradation of cells kept in dark storage was minimal over periods up to one year.

  7. Behavioural repertoire of free-range laying hens indoors and outdoors, and in relation to distance from the shed.

    Science.gov (United States)

    Thuy Diep, A; Larsen, H; Rault, J-L

    2018-04-01

    Access to an outdoor area is believed to allow free-range hens to express a greater behavioural repertoire. However, very little research has been done in this area. We hypothesised that the type and frequency of behaviours would differ between areas that vary in their characteristics and distance from the shed. This preliminary study investigated the behaviour of free-range laying hens in indoor and outdoor areas on one commercial free-range farm, through video recordings and scan sampling of focal hens, with the aim of determining their behavioural repertoire and time budget. While ranging, hens spent most of their time foraging. Indoors, hens preened and rested. Behaviour in the wintergarden showed similarities to both the indoor and outdoor areas, with preening, resting and foraging behaviours. Differences were not in the main behavioural repertoire, but rather in terms of time budget, with access to the range and wintergarden encouraging exploration. There was no difference in the types of behaviours that hens performed in the outdoor range compared with inside the shed, but access to a wintergarden and the outdoor range were favoured by the hens for foraging. © 2018 Australian Veterinary Association.

  8. Indoor and Outdoor Allergies.

    Science.gov (United States)

    Singh, Madhavi; Hays, Amy

    2016-09-01

    In last 30 to 40 years there has been a significant increase in the incidence of allergy. This increase cannot be explained by genetic factors alone. Increasing air pollution and its interaction with biological allergens along with changing lifestyles are contributing factors. Dust mites, molds, and animal allergens contribute to most of the sensitization in the indoor setting. Tree and grass pollens are the leading allergens in the outdoor setting. Worsening air pollution and increasing particulate matter worsen allergy symptoms and associated morbidity. Cross-sensitization of allergens is common. Treatment involves avoidance of allergens, modifying lifestyle, medical treatment, and immunotherapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Indoor and Outdoor Air Pollution- related Health Problem in Ethiopia: Review of Related Literature.

    Science.gov (United States)

    Tefera, Worku; Asfaw, Araya; Gilliland, Frank; Worku, Alemayehu; Wondimagegn, Mehari; Kumie, Abera; Samet, Jonathan; Berhane, Kiros

    2016-01-01

    The health effects of air pollution are generally global problems, but they have, since recently become issues of particular concern for developing countries. This review assessed the situation of air pollution and related health effects in the context of Ethiopia. The materials reviewed in this publication are published scientific papers from online search engines, unpublished government reports and academic theses/dissertations. In addition, interview data obtained from authorities and experts involved in the management of air quality were analyzed, interpreted and reported in the article. Review of the few studies conducted in Ethiopia showed that average concentrations of PM 2.5 reached as high as 280 µg/m 3 for 24-hour measurements (range: 2,417-12,739 µg/m 3 ). Indoor carbon monoxide (CO) levels were universally higher than regulatory limits for the United States and were found to be much higher among households using traditional stoves and solid biomass fuels. The use of traditional stoves and solid biomass fuels was reported in >95% of the households considered. High average levels of NO 2 (97 ppb) were reported in a large longitudinal study. The ambient PM 10 level was below the WHO guideline values in the majority of the samples. About 50% of the on-road CO samples taken from traffic roads in Addis Ababa were found to be less than the guideline values while the number of motor vehicles in Ethiopia is reported to be increasing by more than 9% per annum. There is a very limited air quality monitoring capacity in the country. The co-ordination between stakeholders in this regard is also inadequate. The limited evidence available on health effects of air pollution indicates that the prevalence of acute respiratory illness among children living in households using crude biomass fuels is significantly higher than the national average figures. The limited evidence reviewed and reported in this article indicates high levels of indoor air pollution and trends of

  10. INFORMATION SYSTEM SALES OF INDOOR AND OUTDOOR ORNAMENTAL PLANTS-BASED ONLINE

    Directory of Open Access Journals (Sweden)

    Sutedi Sutedi

    2017-05-01

    Full Text Available Ornamental plants have fairly high commercial value and much sought after by various circles. The prospect is in the business of ornamental plants can be said very brilliant and profitable. Where is in the business of ornamental plants can bring about advantages not the least. The business struggled with ornamental plants can have very favorable prospects for the long term. There are an awful lot of various kinds of ornamental plants that we can choose to use as ornaments to beautify residential home. The ornamental plants can be used as indoor ornamental plants placed in homes or can also be used as outdoor ornamental plants grown in the garden. Ornamental plants while more popular community-wide information system for ornamental plant however is currently designed specifically and not many people who know the information on price and specs or type of indoor and outdoor ornamental plants so that the need for sales information system of indoor and outdoor ornamental plants-based online. With the sales information system of Indoor and Outdoor ornamental plants-based online is expected to facilitate the customers, business processes that occur in the company's units, unit – units that exist within the system a functioning production units as the unit working on/produce ornamental plants. With the utilization of the system marketing media, promoting, finding new customers, the sales process, recapitulation payment of ornamental plants, control the conditions of stock products, development and delivery of products to customers including convincing the product gets to the customer

  11. A Critical Review of Naphthalene Sources and Exposures Relevant to Indoor and Outdoor Air

    Directory of Open Access Journals (Sweden)

    Chunrong Jia

    2010-07-01

    Full Text Available Both the recent classification of naphthalene as a possible human carcinogen and its ubiquitous presence motivate this critical review of naphthalene’s sources and exposures. We evaluate the environmental literature on naphthalene published since 1990, drawing on nearly 150 studies that report emissions and concentrations in indoor, outdoor and personal air. While naphthalene is both a volatile organic compound and a polycyclic aromatic hydrocarbon, concentrations and exposures are poorly characterized relative to many other pollutants. Most airborne emissions result from combustion, and key sources include industry, open burning, tailpipe emissions, and cigarettes. The second largest source is off-gassing, specifically from naphthalene’s use as a deodorizer, repellent and fumigant. In the U.S., naphthalene’s use as a moth repellant has been reduced in favor of para-dichlorobenzene, but extensive use continues in mothballs, which appears responsible for some of the highest indoor exposures, along with off-label uses. Among the studies judged to be representative, average concentrations ranged from 0.18 to 1.7 μg m-3 in non-smoker’s homes, and from 0.02 to 0.31 μg m-3 outdoors in urban areas. Personal exposures have been reported in only three European studies. Indoor sources are the major contributor to (non-occupational exposure. While its central tendencies fall well below guideline levels relevant to acute health impacts, several studies have reported maximum concentrations exceeding 100 μg m-3, far above guideline levels. Using current but draft estimates of cancer risks, naphthalene is a major environmental risk driver, with typical individual risk levels in the 10-4 range, which is high and notable given that millions of individuals are exposed. Several factors influence indoor and outdoor concentrations, but the literature is inconsistent on their effects. Further investigation is needed to better characterize naphthalene

  12. Accelerometer Measured Level of Physical Activity Indoors and Outdoors During Preschool Time in Sweden and the United States

    DEFF Research Database (Denmark)

    Raustorp, A.; Pagels, P.; Boldemann, C.

    2012-01-01

    BACKGROUND: It is important to understand the correlates of physical activity in order to influence policy and create environments that promote physical activity among preschool children. We compared preschoolers' physical activity in Swedish and in US settings and objectively examined differences...... boys and girls indoor and outdoor physical activity regarding different intensity levels and sedentary behaviour. METHODS: Accelerometer determined physical activity in 50 children with mean age 52 months, (range 40-67) was recorded during preschool time for 5 consecutive weekdays at four sites...

  13. Exposure to secondhand smoke in terraces and other outdoor areas of hospitality venues in eight European countries.

    Science.gov (United States)

    López, Maria J; Fernández, Esteve; Gorini, Giuseppe; Moshammer, Hanns; Polanska, Kinga; Clancy, Luke; Dautzenberg, Bertrand; Delrieu, Agnes; Invernizzi, Giovanni; Muñoz, Glòria; Precioso, Jose; Ruprecht, Ario; Stansty, Peter; Hanke, Wojciech; Nebot, Manel

    2012-01-01

    Outdoor secondhand smoke (SHS) concentrations are usually lower than indoor concentrations, yet some studies have shown that outdoor SHS levels could be comparable to indoor levels under specific conditions. The main objectives of this study were to assess levels of SHS exposure in terraces and other outdoor areas of hospitality venues and to evaluate their potential displacement to adjacent indoor areas. Nicotine and respirable particles (PM2.5) were measured in outdoor and indoor areas of hospitality venues of 8 European countries. Hospitality venues of the study included night bars, restaurants and bars. The fieldwork was carried out between March 2009 and March 2011. We gathered 170 nicotine and 142 PM2.5 measurements during the study. The median indoor SHS concentration was significantly higher in venues where smoking was allowed (nicotine 3.69 µg/m3, PM2.5: 120.51 µg/m3) than in those where smoking was banned (nicotine: 0.48 µg/m3, PM2.5: 36.90 µg/m3). The median outdoor nicotine concentration was higher in places where indoor smoking was banned (1.56 µg/m3) than in venues where smoking was allowed (0.31 µg/m3). Among the different types of outdoor areas, the highest median outdoor SHS levels (nicotine: 4.23 µg/m3, PM2.5: 43.64 µg/m3) were found in the semi-closed outdoor areas of venues where indoor smoking was banned. Banning indoor smoking seems to displace SHS exposure to adjacent outdoor areas. Furthermore, indoor settings where smoking is banned but which have a semi-closed outdoor area have higher levels of SHS than those with open outdoor areas, possibly indicating that SHS also drifts from outdoors to indoors. Current legislation restricting indoor SHS levels seems to be insufficient to protect hospitality workers--and patrons--from SHS exposure. Tobacco-free legislation should take these results into account and consider restrictions in the terraces of some hospitality venues to ensure effective protection.

  14. Indoor air quality in urban and rural kindergartens: short-term studies in Silesia, Poland.

    Science.gov (United States)

    Błaszczyk, Ewa; Rogula-Kozłowska, Wioletta; Klejnowski, Krzysztof; Kubiesa, Piotr; Fulara, Izabela; Mielżyńska-Švach, Danuta

    2017-01-01

    More than 80% of people living in urban areas who monitor air pollution are exposed to air quality levels that exceed limits defined by the World Health Organization (WHO). Although all regions of the world are affected, populations in low-income cities are the most impacted. According to average annual levels of fine particulate matter (PM2.5, ambient particles with aerodynamic diameter of 2.5 μm or less) presented in the urban air quality database issued by WHO in 2016, as many as 33 Polish cities are among the 50 most polluted cities in the European Union (EU), with Silesian cities topping the list. The aim of this study was to characterize the indoor air quality in Silesian kindergartens based on the concentrations of gaseous compounds (SO 2 , NO 2 ), PM2.5, and the sum of 15 PM2.5-bound polycyclic aromatic hydrocarbons (PAHs), including PM2.5-bound benzo(a)pyrene (BaP), as well as the mutagenic activity of PM2.5 organic extracts in Salmonella assay (strains: TA98, YG1024). The assessment of the indoor air quality was performed taking into consideration the pollution of the atmospheric air (outdoor). I/O ratios (indoor/outdoor concentration) for each investigated parameter were also calculated. Twenty-four-hour samples of PM2.5, SO 2 , and NO 2 were collected during spring in two sites in southern Poland (Silesia), representing urban and rural areas. Indoor samples were taken in naturally ventilated kindergartens. At the same time, in the vicinity of the kindergarten buildings, the collection of outdoor samples of PM2.5, SO 2 , and NO 2 was carried out. The content of BaP and the sum of 15 studied PAHs was determined in each 24-h sample of PM2.5 (indoor and outdoor). In the urban site, statistically lower concentrations of SO 2 and NO 2 were detected indoors compared to outdoors, whereas in the rural site, such a relationship was observed only for NO 2 . No statistically significant differences in the concentrations of PM2.5, PM2.5-bound BaP, and Σ15 PAHs

  15. Prediction of Indoor Air Exposure from Outdoor Air Quality Using an Artificial Neural Network Model for Inner City Commercial Buildings.

    Science.gov (United States)

    Challoner, Avril; Pilla, Francesco; Gill, Laurence

    2015-12-01

    NO₂ and particulate matter are the air pollutants of most concern in Ireland, with possible links to the higher respiratory and cardiovascular mortality and morbidity rates found in the country compared to the rest of Europe. Currently, air quality limits in Europe only cover outdoor environments yet the quality of indoor air is an essential determinant of a person's well-being, especially since the average person spends more than 90% of their time indoors. The modelling conducted in this research aims to provide a framework for epidemiological studies by the use of publically available data from fixed outdoor monitoring stations to predict indoor air quality more accurately. Predictions are made using two modelling techniques, the Personal-exposure Activity Location Model (PALM), to predict outdoor air quality at a particular building, and Artificial Neural Networks, to model the indoor/outdoor relationship of the building. This joint approach has been used to predict indoor air concentrations for three inner city commercial buildings in Dublin, where parallel indoor and outdoor diurnal monitoring had been carried out on site. This modelling methodology has been shown to provide reasonable predictions of average NO₂ indoor air quality compared to the monitored data, but did not perform well in the prediction of indoor PM2.5 concentrations. Hence, this approach could be used to determine NO₂ exposures more rigorously of those who work and/or live in the city centre, which can then be linked to potential health impacts.

  16. Measurement of indoor and outdoor radon concentrations during Superstorm Sandy.

    Science.gov (United States)

    Kotrappa, Payasada; Paul, Prateek; Stieff, Alex; Stieff, Frederick

    2013-12-01

    Superstorm Sandy affected much of the US East Coast extending over 1800 km. It passed over the test location in the State of Maryland on 29 October 2012. Being 350 km away from the regions of highest intensity the storm was of lower intensity at the test location. Continuous radon monitors and passive radon monitors were used for the measurement. The test location was the basement of a single family home representing the indoor concentration. A partially opened garage of the same test home represented the outdoor radon concentration. In 24 h, the atmospheric pressure dropped from 990 to 960 mbar and the indoor radon concentration increased from 70 to 1500 Bq m(-3) and returned to the normal of 70 Bq m(-3) at the end of the storm. Throughout the storm, the outdoor radon concentration was not significantly affected. Probable reasons for such surprisingly large changes are discussed. However, the outdoor temperature dropped from 13°C to 7°C during the radon peak.

  17. Integrated indoor and outdoor exposure assessment framework for fine particulate matter pollution

    DEFF Research Database (Denmark)

    McKone, Thomas E; Hodas, Natasha; Apte, Joshua S.

    2016-01-01

    The 2010 Global Burden of Disease report demonstrates that fine particulate matter (PM2.5) pollution is the major environmental contributor to mortality. Exposures outdoors (ambient) and indoors (household) contribute almost qually to this burden. Unfortunately, the health impacts from exposure t...

  18. Indoor PM2.5 in an urban zone with heavy wood smoke pollution: The case of Temuco, Chile.

    Science.gov (United States)

    Jorquera, Héctor; Barraza, Francisco; Heyer, Johanna; Valdivia, Gonzalo; Schiappacasse, Luis N; Montoya, Lupita D

    2018-05-01

    Temuco is a mid-size city representative of severe wood smoke pollution in southern Chile; however, little is known about the indoor air quality in this region. A field measurement campaign at 63 households in the Temuco urban area was conducted in winter 2014 and is reported here. In this study, indoor and outdoor (24-hr) PM 2.5 and its elemental composition were measured and compared. Infiltration parameters and outdoor/indoor contributions to indoor PM 2.5 were also determined. A statistical evaluation of how various air quality interventions and household features influence indoor PM 2.5 was also performed. This study determined median indoor and outdoor PM 2.5 concentrations of 44.4 and 41.8 μg/m 3 , respectively. An average infiltration factor (0.62 ± 0.06) was estimated using sulfur as a tracer species. Using a simple mass balance approach, median indoor and outdoor contributions to indoor PM 2.5 concentrations were then estimated as 12.5 and 26.5 μg/m 3 , respectively; therefore, 68% of indoor PM 2.5 comes from outdoor infiltration. This high percentage is due to high outdoor pollution and relatively high household air exchange rates (median: 1.06 h -1 ). This study found that S, Br and Rb were dominated by outdoor contributions, while Si, Ca, Ti, Fe and As originated from indoor sources. Using continuous indoor and outdoor PM 2.5 measurements, a median indoor source strength of 75 μg PM 2.5 /min was estimated for the diurnal period, similar to literature results. For the evening period, the median estimate rose to 135 μg PM 2.5 /min, reflecting a more intense wood burning associated to cooking and space heating at night. Statistical test results (at the 90% confidence level) support the ongoing woodstove replacement program (reducing emissions) and household weatherization subsidies (reducing heating demand) for improving indoor air quality in southern Chile, and suggest that a cookstove improvement program might be helpful as well

  19. Searching for Authentic Context in Designing PISA-like Mathematics Problem: From Indoor to Outdoor Field Experience

    Science.gov (United States)

    Siswono, T. Y. E.; Kohar, A. W.; Rosyidi, A. H.; Hartono, S.; Masriyah

    2018-01-01

    Designing problem like in PISA is known as a challenging activity for teachers particularly as the use of authentic context within that type of problem. This paper aims to describe the experiences of secondary mathematics teachers in designing PISA-like problems within an innovative training program focusing on building teachers’ understanding on the concept of mathematical literacy. The teachers were engaged in a set of problem-solving and problem-posing activities using PISA-based problem within indoor and outdoor field experiences. Within indoor field experience, the teachers worked collaboratively in groups on designing PISA-like problems with a given context through problem generation and reformulation techniques. Within outdoor field experience, they worked on designing PISA-like problems with self-chosen context from the place where the outdoor field experience took place. Our analysis indicates that there were improvements on the PISA-like problems designed by teachers based on its level use of context from indoor to outdoor experience. Also, the teachers were relatively successful with creating appropriate and motivating contexts by harnessing a variety of context consisting of personal, occupational, societal, and scientific contexts. However, they still experienced difficulties in turning these contexts into an appropriate problem satisfying PISA framework such as regarding authenticity of context use, language structure, and PISA task profile.

  20. Effectiveness of using pure copper and silver coupon corrosivity monitoring (CCM) metal strips to measure the severity levels of air pollutants in indoor and outdoor atmospheres

    CSIR Research Space (South Africa)

    Foax, LJ

    2008-10-01

    Full Text Available Severity levels of air pollutants rich in oxides, chlorides and sulphides were successfully measured in indoor and outdoor atmospheres using pure copper and silver coupon corrosivity monitoring (CCM) metal strips when the maximum exposure periods...

  1. Vehicle emissions and effects on air quality: indoors and outdoors

    International Nuclear Information System (INIS)

    Perry, R.; Gee, I.L.

    1994-01-01

    Vehicle emissions of non-regulated volatile organic compounds (VOCs), such as benzene, can form a major contribution to pollution of the indoor as well as the outdoor environment. Several of these compounds are considered to be a health risk and are important factors in the production of photochemical smog. The introduction of unleaded and particularly 'super unleaded' fuels has significantly increased levels of aromatic compounds in petrol world-wide and has led to changes in fuel composition with respect to olefins and the use of oxygenates. Increased aromatics, olefins and other compounds in fuels used in vehicles not fitted with catalytic converters have shown to increase emissions of benzene, 1,4-budatiene and other VOCs as well as contributing to increases in photochemical smog precursors. Increases in VOC levels in ambient air clearly produce increased indoor air pollution, particularly in naturally ventilated buildings. (author) 6 figs., 5 tabs., 30 refs

  2. Prediction of indoor concentration of 0.5-4 µm particles of outdoor origin in an uninhabited apartment

    DEFF Research Database (Denmark)

    Schneider, T.; Jensen, K.A.; Clausen, P.A.

    2004-01-01

    Indoor and outdoor particle size distributions, indoor-outdoor pressure difference, indoor air-exchange rate, and meteorological conditions were measured at an uninhabited apartment located in a busy street in Copenhagen during 1-month long fall, winter and spring campaigns. Particle penetration...... was estimated from concentration rebound measurements following HEPA filtering of the indoor air by fitting a simple deterministic model. The model included measured air exchange rates and published surface deposition loss rates. This model was then used to predict indoor particle concentration. The model...

  3. Characterization of Indoor and Outdoor Aerosols in a Suburban Area of Prague

    International Nuclear Information System (INIS)

    Smolik, J.; Dohanyosova, P.; Schwarz, J.; Zdimal, V.; Lazaridis, M.

    2008-01-01

    The mass, ionic and elemental size distributions of particulate matter (PM) measured indoors and outdoors in an apartment situated in a north-westward suburb of Prague are presented. The PM samples were collected by two Berner type low pressure impactors separating particles into 10 size fractions from 26 nm to 10 μm and were further analyzed by ion chromatography (IC) and proton induced X-ray emission (PIXE). Temperature, pressure and relative humidity were measured both indoors and outdoors parallel to PM sampling. The indoor and outdoor PM dynamics were recorded by two scanning mobility particle sizers (SMPS) and an aerodynamic particle sizer (APS). Finally, the ventilation rate was determined by a radon technique. Ion chromatography showed that the major inorganic components of the fine particle mode are sulfate, nitrate, and ammonium with very low indoor nitrate concentration. Crustal elements (Al, Si, Ca, Ti, Mn, and Fe) were associated with the coarse aerosol mode. The presence of people increased the mass concentration of coarse particles, whereas cooking, smoking, and burning of incense and candles contributed predominantly to the fine particle mode. Smoking and the burning of incense also increased the concentration of potassium, bromine and chlorine content in fine particles

  4. Personal exposure to PM2.5, black smoke and NO2 in Copenhagen: relationship to bedroom and outdoor concentrations covering seasonal variation.

    Science.gov (United States)

    Sørensen, Mette; Loft, Steffen; Andersen, Helle Vibeke; Raaschou-Nielsen, Ole; Skovgaard, Lene Theil; Knudsen, Lisbeth E; Nielsen, Ivan V; Hertel, Ole

    2005-09-01

    Epidemiological studies have found negative associations between human health and particulate matter in urban air. In most studies outdoor monitoring of urban background has been used to assess exposure. In a field study, personal exposure as well as bedroom, front door and background concentrations of PM(2.5), black smoke (BS), and nitrogen dioxide (NO(2)) were measured during 2-day periods in 30 subjects (20-33 years old) living and studying in central parts of Copenhagen. The measurements were repeated in the four seasons. Information on indoor exposure sources such as environmental tobacco smoke (ETS) and burning of candles was collected by questionnaires. The personal exposure, the bedroom concentration and the front door concentration was set as outcome variable in separate models and analysed by mixed effect model regression methodology, regarding subject levels as a random factor. Seasons were defined as a dichotomised grouping of outdoor temperature (above and below 8 degrees C). For NO(2) there was a significant association between personal exposure and both the bedroom, the front door and the background concentrations, whereas for PM(2.5) and BS only the bedroom and the front door concentrations, and not the background concentration, were significantly associated to the personal exposure. The bedroom concentration was the strongest predictor of all three pollution measurements. The association between the bedroom and front door concentrations was significant for all three measurements, and the association between the front door and the background concentrations was significant for PM(2.5) and NO(2), but not for BS, indicating greater spatial variation for BS than for PM(2.5) and NO(2). For NO(2), the relationship between the personal exposure and the front door concentration was dependent upon the "season", with a stronger association in the warm season compared with the cold season, and for PM(2.5) and BS the same tendency was seen. Time exposed to

  5. Review of the health risks associated with nitrogen dioxide and sulfur dioxide in indoor air

    International Nuclear Information System (INIS)

    Brauer, M.; Henderson, S.; Kirkham, T.; Lee, K.S.; Rich, R.; Teschke, K.

    2002-01-01

    The scientific literature on the health effects of nitrogen dioxide (NO 2 ) and sulfur dioxide (SO 2 ) were reviewed with particular focus on the chemical and physical properties of the 2 gases and the toxicological characteristics identified in animal studies at exposure concentrations near the rate of ambient human exposures. The study also examined the expected levels of non-industrial indoor exposure of Canadians compared to other regions with similar climates. The sources of indoor pollution were also reviewed, along with the contribution of outdoor pollution to indoor levels. Results from epidemiological studies of indoor exposures in homes, offices and schools were also presented. For each pollutant, the study identified anthropogenic sources, indoor sources, toxicological characteristics, biochemistry, pulmonary effects, immune response, and other effects. Indoor sources of NO 2 include gas-fired appliances, pilot lights, hot water heaters, kerosene heaters, and tobacco smoke. The impact of ventilation on both NO 2 and SO 2 levels was also examined. Outdoor sources such as traffic can also contribute to indoor levels, particularly in urban areas. In the case of SO 2 , coal heating and cooling appear to be associated in increased indoor levels. The epidemiological studies that were reviewed failed in general to indicate an association between NO 2 exposure and a wide range of health impacts. The studies, however, indicate that asthmatics are more susceptible to the effects of NO 2 exposure. In the case of SO 2 , evidence suggests that it has a chronic effect on lung function and respiratory symptoms and disease. 243 refs., 13 tabs

  6. Concentrations and determinants of NO{sub 2} in homes of Ashford, UK and Barcelona and Menorca, Spain

    Energy Technology Data Exchange (ETDEWEB)

    Algar, O.G.; Puig, C.; Vall, O. [Hospital del Mar, Pediatrics, and Univ. Autonoma de Barcelona, Barcelona (Spain); Pichini, S. [Istituto Superiore di Sanita, Drug Research and Control Dept., Rome (Italy); Basagana, X. [Institut Municipal Investigacio Medica, Barcelona (Spain); Torrent, M. [INSALUD, Area de Salud de Menorca, Menorca Island (Spain); Harris, J.; Cullinan, P. [Imperial College, Dept. of Occupational and Environmental Med., London (United Kingdom); Sunyer, J. [Univ. Pompeu Fabra, Barcelona (Spain)

    2004-08-01

    The study examined indoor nitrogen dioxide (NO{sub 2}) concentrations in Ashford, Kent (UK), Menorca Island and Barcelona city (Spain) and the contribution of their most important indoor determinants (e.g. gas combustion appliances and cigarette smoking). The homes examined (n = 1421) were those from infants recruited for the Asthma Multicentre Infants Cohort Study, which aimed to assess, using a standard protocol, the effects of pre- and post-natal environmental exposures in the inception of atopy and asthma. Indoor NO{sub 2} was measured using passive filter badges placed on a living room wall of the hoes for between 7 and 15 days. Homes in the three centers had significantly diffent concentrations of indoor NO{sub 2}, with those in Barcelona showing the highest levels (median NO{sub 2} levels: 5.79, 6.06 and 23.87 p.p.b. in Ashford, Menorca and Barcelona, respectively). Multiple regression analysis showed that the principal indoor determinants of NO{sub 2} concentrations in the three cohorts were the heating/cooking fuel used in the house (gas fire increased average NO{sub 2} concentrations by 1.27-fold and gas cooker by 2.13 times), parental cigarette smoking and season of measurement. Those variable significantly related to indoor NO{sub 2} concentration in Ashford, Barcelona and Menorca, respectively. In all the cohorts combined, 52% of the variation could be explained in this way. Although outdoor NO{sub 2} was not measured concurrently, its additional contribution was estimated. In conclusion, despite differences in indoore NO{sub 2} mean concentrations probably reflecting different outdoor NO{sub 2} level, home factors affecting indoor NO{sub 2} values and their specific contributions were constant across the their cohorts. (au)

  7. Chemical Characterization of the Indoor Air Quality of a University Hospital: Penetration of Outdoor Air Pollutants

    NARCIS (Netherlands)

    Scheepers, P.T.J.; Wel, L. van; Beckmann, G.; Anzion, R.B.M.

    2017-01-01

    For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ). The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two

  8. Chemical Characterization of the Indoor Air Quality of a University Hospital : Penetration of Outdoor Air Pollutants

    NARCIS (Netherlands)

    Scheepers, Paul T J; Van Wel, Luuk; Beckmann, Gwendolyn; Anzion, Rob B M

    2017-01-01

    For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ). The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two

  9. Assessment of indoor and outdoor airborne fungi in an Educational, Research and Treatment Center

    Directory of Open Access Journals (Sweden)

    Nasrin Rostami

    2016-06-01

    Full Text Available Hospital environments contain different types of microorganisms. Airborne fungi are one of these microbes and the major source of hospital indoor contamination that will be able to cause airborne fungal diseases. In the current study, the total count and diversity of the airborne filamentous and yeasts fungi were investigated in indoor and outdoor air of selective wards of Emam Reza Educational, Research and Treatment Center. This cross-sectional study was performed during the fall season. One hundred and ninety-two environmental samples of indoor and outdoor air from hematology, infectious diseases, Ear, Nose and Throat (ENT and Neonatal Intensive Care Unit (NICU wards were collected by open plate technique (on Sabouraud dextrose agar media once a week. The cultures were then examined and evaluated according to macroscopic and microscopic examination criteria. In this study, 67 (62.03% of indoor samples and 81 (96.42% of outdoor samples were positive for fungi. The most isolated fungi were yeast species (17.12%, Penicillium spp. (16.34%, Alternaria spp. (14.39%, Aspergillus niger (11.28%, A. flavus (8.95%, respectively. Almost all of the wards showed high rates of contamination by various fungi. However, the analysis of the data showed that indoor air of hematology ward had the highest fungal pollution. In contrast, the outdoor air of ENT had the highest fungal pollution. Thus, these results demonstrated that the cleansing and disinfection procedures in the hospital wards should be improved yet.

  10. An Empirical Outdoor-to-Indoor Path Loss Model from below 6 GHz to cm-Wave Frequency Bands

    DEFF Research Database (Denmark)

    Rodriguez Larrad, Ignacio; Nguyen, Huan Cong; Kovács, István Z.

    2017-01-01

    This letter presents an empirical multi-frequency outdoor-to-indoor path loss model. The model is based on measurements performed on the exact same set of scenarios for different frequency bands ranging from traditional cellular allocations below 6 GHz (0.8, 2, 3.5 and 5.2 GHz), up to cm-wave fre......This letter presents an empirical multi-frequency outdoor-to-indoor path loss model. The model is based on measurements performed on the exact same set of scenarios for different frequency bands ranging from traditional cellular allocations below 6 GHz (0.8, 2, 3.5 and 5.2 GHz), up to cm...

  11. An Integrated Approach to Indoor and Outdoor Localization

    Science.gov (United States)

    2017-04-17

    TITLE AND SUBTITLE An Integrated Approach to Indoor and Outdoor Localization 5a.  CONTRACT NUMBER 5b.  GRANT NUMBER FA9550-12-1-0299 5c.   PROGRAM ELEMENT...Distribution approved for public release. Figure 5: A flowchart of the method of computing an initial position estimate by comparing a single WiFi scan

  12. Outdoor smoking behaviour and support for outdoor smoking restrictions before and after France's national smoking ban.

    Science.gov (United States)

    Kennedy, Ryan David; Behm, Ilan; Craig, Lorraine; Thompson, Mary E; Fong, Geoffrey T; Guignard, Romain; Beck, Francois

    2012-02-01

    On January 1, 2008, the French government implemented a national ban on indoor smoking in hospitality venues. Survey results indicate the indoor ban has been successful at dramatically reducing indoor smoking; however, there are reports of an increased number of outdoor hospitality spaces (patios) where smoking can take place. This study sought to understand if the indoor ban simply moved smoking to the outdoors, and to assess levels of support for smoking restrictions in outdoor hospitality settings after the smoke-free law. Telephone interviews were conducted among 1067 adult smokers before and after the 2008 indoor ban as part of the International Tobacco Control (ITC) France Survey. Among other topics, this survey measures how the smoking ban has influenced smoking behaviour relevant to outdoor sections of hospitality venues. In addition, 414 non-smoking adults and 164 respondents who had quit smoking between waves were also asked about support for outdoor smoking restrictions. Reported smoking outdoors at cafés/pubs/bars increased from 33.6% of smokers at Wave 1 to 75.9% at Wave 2. At restaurants, smoking outdoors increased from 28.9% to 59.0%. There was also an increase in reported non-smoking for both visits to cafés/pubs/bars, and restaurants from 13.4% to 24.7%, and 30.4% to 40.8% respectively. The majority of smokers (74.5%), non-smokers (89.4%) and quitters (74.0%) support a partial or complete ban on smoking in outdoor areas of restaurants. The indoor smoking ban moved smoking to outdoor spaces; however, the ban is also associated with increased non-smoking behaviour. The majority of respondents support outdoor smoking restrictions in patio environments.

  13. INDOOR AND OUTDOOR SOURCE CONTRIBUTIONS TO PERSONAL PM2.5 FOR A PANEL OF INDIVIDUALS WITH CARDIOVASCULAR DISEASE OR COPD LIVING IN BOSTON, MA

    Science.gov (United States)

    Repeated personal, home indoor, home outdoor, and ambient particulate and gaseous pollutant levels were characterized for individuals with cardiovascular disease or COPD and their partners living in the Boston area. Health status was determined by self-reported history of myoc...

  14. Simulating indoor concentrations of NO(2) and PM(2.5) in multifamily housing for use in health-based intervention modeling.

    Science.gov (United States)

    Fabian, P; Adamkiewicz, G; Levy, J I

    2012-02-01

    Residents of low-income multifamily housing can have elevated exposures to multiple environmental pollutants known to influence asthma. Simulation models can characterize the health implications of changing indoor concentrations, but quantifying the influence of interventions on concentrations is challenging given complex airflow and source characteristics. In this study, we simulated concentrations in a prototype multifamily building using CONTAM, a multizone airflow and contaminant transport program. Contaminants modeled included PM(2.5) and NO(2) , and parameters included stove use, presence and operability of exhaust fans, smoking, unit level, and building leakiness. We developed regression models to explain variability in CONTAM outputs for individual sources, in a manner that could be utilized in simulation modeling of health outcomes. To evaluate our models, we generated a database of 1000 simulated households with characteristics consistent with Boston public housing developments and residents and compared the predicted levels of NO(2) and PM(2.5) and their correlates with the literature. Our analyses demonstrated that CONTAM outputs could be readily explained by available parameters (R(2) between 0.89 and 0.98 across models), but that one-compartment box models would mischaracterize concentrations and source contributions. Our study quantifies the key drivers for indoor concentrations in multifamily housing and helps to identify opportunities for interventions. Many low-income urban asthmatics live in multifamily housing that may be amenable to ventilation-related interventions such as weatherization or air sealing, wall and ceiling hole repairs, and exhaust fan installation or repair, but such interventions must be designed carefully given their cost and their offsetting effects on energy savings as well as indoor and outdoor pollutants. We developed models to take into account the complex behavior of airflow patterns in multifamily buildings, which can

  15. Indoor and Outdoor Mobile Mapping Systems for Architectural Surveys

    Science.gov (United States)

    Campi, M.; di Luggo, A.; Monaco, S.; Siconolfi, M.; Palomba, D.

    2018-05-01

    This paper presents the results of architectural surveys carried out with mobile mapping systems. The data acquired through different instruments for both indoor and outdoor surveying are analyzed and compared. The study sample shows what is required for an acquisition in a dynamic mode indicating the criteria for the creation of a georeferenced network for indoor spaces, as well as the operational processes concerning data capture, processing, and management. The differences between a dynamic and static scan have been evaluated, with a comparison being made with the aerial photogrammetric survey of the same sample.

  16. [The community succession of sarcosaphagous insects on pig carcasses in summer indoor and outdoor environment in Shenzhen area].

    Science.gov (United States)

    Yin, Xiao-Jun; Ma, Meng-Yun; Zhou, Hui; Lai, Yue; Wang, Jiang-Feng

    2014-06-01

    To explore the growing development and community succession of main sarcosaphagous insects on pig carcasses in summer indoor and outdoor environment in Shenzhen area and to estimate the postmortem interval (PMI). From early May to August in 2013, in Forensic Medical Examination Center of Shenzhen Public Security Bureau, the main insect species and the decomposition process were observed in two adult pig carcasses of simulative indoor and outdoor environment. The different decomposition stages and the community succession of insects were recorded. The indoor and outdoor pig carcasses showed skeleton 412.5 and 325 hours after death, respectively. The main species of flies on pig carcasses were Chrysomya megacephala, Chrysomya rufifacies and Chrysomya chani. The main species of beetles were Crecphilus maxillosus, Necrobia ruficollis, Saprinus splendens and Dermestes maculatu. The dominant species of flies in the outdoor pig carcasses obviously produced the second generations due to the effect of mass rainfall, nor in the indoor pig carcasses. There are regular patterns on the community succession of insects on pig carcasses in summer indoor and outdoor environment in Shenzhen area. The activity patterns of seven typical insects and their larva show important value for estimating PMI.

  17. Indoor Levels of Formaldehyde and Other Pollutants and Relationship to Air Exchange Rates and Human Activities

    Science.gov (United States)

    Huangfu, Y.; O'Keeffe, P.; Kirk, M.; Walden, V. P.; Lamb, B. K.; Jobson, B. T.

    2017-12-01

    This paper reports results on an indoor air quality study conducted on six homes in summer and winter, contrasting indoor and outdoor concentrations of O3, CO, CO2, NOx, PM2.5, and selected volatile organic hydrocarbons measured by PTR-MS. Data were collected as 1 minute averages. Air exchange rates of the homes were determined by CO2 tracer release. Smart home sensors, recording human activity level in various places in the home, and window and doors openings, were utilized to better understand the link between human activity and indoor air pollution. From our study, averaged air exchange rates of the homes ranged from 0.2 to 1.2 hour-1 and were greatly affected by the ventilation system type and window and door openings. In general, a negative correlation between air exchange rate and indoor VOCs levels was observed, with large variation of pollutant levels between the homes. For most of the VOCs measured in the house, including formaldehyde and acetaldehyde, summer levels were much higher than winter levels. In some homes formaldehyde levels displayed a time of day variation that was linked to changes in indoor temperature. During a wildfire period in the summer of 2015, outdoor levels of PM2.5, formaldehyde, and benzene dramatically increased, significantly impacting indoor levels due to infiltration. Human activities, such as cooking, can significantly change the levels of most of the compounds measured in the house and the levels can be significantly elevated for short periods of time, with peak levels can be several orders higher compared with typical levels. The data suggest that an outcome of state energy codes that require new homes to be energy efficient, and as a consequence built with lower air exchange rates, will be unacceptable levels of air toxics, notably formaldehyde.

  18. FIELD COMPARISONS OF DUAL SMPS-APS SYSTEMS TO MEASURE INDOOR-OUTDOOR PARTICLE SIZE DISTRIBUTIONS

    Science.gov (United States)

    Simultaneous measurements of particle size distributions across multiple locations can provide critical information to accurately assess human exposure to particles. These data are very useful to describe indoor-outdoor particle relationships, outdoor particle penetration thro...

  19. Detection of fluorotelomer alcohols in indoor environments and their relevance for human exposure.

    Science.gov (United States)

    Schlummer, Martin; Gruber, Ludwig; Fiedler, Dominik; Kizlauskas, Markus; Müller, Josef

    2013-07-01

    Fluorotelomer alcohols (FTOH) are important precursors of perfluorinated carboxylic acids (PFCA). These neutral and volatile compounds are frequently found in indoor air and may contribute to the overall human exposure to per- and polyfluorinated alkyl substances (PFAS). In this study air samples of ten workplace environments and a car interior were analysed. In addition, extracts and emissions from selected outdoor textiles were analysed in order to establish their potential contribution to the indoor levels of the above-mentioned compounds. Concentrations of FTOHs measured in air ranged from 0.15 to 46.8, 0.25 to 286, and 0.11 to 57.5ng/m(3) for 6:2, 8:2 and 10:2 FTOHs, respectively. The highest concentrations in air were identified in shops selling outdoor clothing, indicating outdoor textiles to be a relevant source of FTOH in indoor workplace environments. Total amounts of FTOH in materials of outdoor textiles accounted for selling outdoor textiles contains the highest levels of FTOH. Exposure of humans to perfluorooctanoic acid (PFOA) through absorption of FTOH and subsequent degradation is discussed on the basis of indoor air levels. Calculation of indoor air-related exposure using the median of the measured air levels revealed that exposure is on the same order of magnitude as the recently reported dietary intakes for a background-exposed population. On the basis of the 95th percentile, indoor air exposure to PFOA was estimated to exceed dietary exposure. However, indoor air-related intakes of FTOH are far below the tolerable daily intake (TDI) of PFOA, indicating that there is no risk to health, even when assuming an unrealistic complete degradation of FTOH into PFOA. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Seasonal variation in outdoor, indoor, and personal air pollution exposures of women using wood stoves in the Tibetan Plateau: Baseline assessment for an energy intervention study.

    Science.gov (United States)

    Ni, Kun; Carter, Ellison; Schauer, James J; Ezzati, Majid; Zhang, Yuanxun; Niu, Hongjiang; Lai, Alexandra M; Shan, Ming; Wang, Yuqin; Yang, Xudong; Baumgartner, Jill

    2016-09-01

    Cooking and heating with coal and biomass is the main source of household air pollution in China and a leading contributor to disease burden. As part of a baseline assessment for a household energy intervention program, we enrolled 205 adult women cooking with biomass fuels in Sichuan, China and measured their 48-h personal exposure to fine particulate matter (PM2.5) and carbon monoxide (CO) in winter and summer. We also measured the indoor 48-h PM2.5 concentrations in their homes and conducted outdoor PM2.5 measurements during 101 (74) days in summer (winter). Indoor concentrations of CO and nitrogen oxides (NO, NO2) were measured over 48-h in a subset of ~80 homes. Women's geometric mean 48-h exposure to PM2.5 was 80μg/m(3) (95% CI: 74, 87) in summer and twice as high in winter (169μg/m(3) (95% CI: 150, 190), with similar seasonal trends for indoor PM2.5 concentrations (winter: 252μg/m(3); 95% CI: 215, 295; summer: 101μg/m(3); 95% CI: 91, 112). We found a moderately strong relationship between indoor PM2.5 and CO (r=0.60, 95% CI: 0.46, 0.72), and a weak correlation between personal PM2.5 and CO (r=0.41, 95% CI: -0.02, 0.71). NO2/NO ratios were higher in summer (range: 0.01 to 0.68) than in winter (range: 0 to 0.11), suggesting outdoor formation of NO2 via reaction of NO with ozone is a more important source of NO2 than biomass combustion indoors. The predictors of women's personal exposure to PM2.5 differed by season. In winter, our results show that primary heating with a low-polluting fuel (i.e., electric stove or wood-charcoal) and more frequent kitchen ventilation could reduce personal PM2.5 exposures. In summer, primary use of a gaseous fuel or electricity for cooking and reducing exposure to outdoor PM2.5 would likely have the greatest impacts on personal PM2.5 exposure. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Indoor-outdoor relationship of fungal aerosols in domestic homes situated in humid-warm climate

    International Nuclear Information System (INIS)

    ACeron Palma, I. M.; Lopez Pacheco, M.; Perez Sanchez, M. M.; Quintal Franco, C.; Giacoman Vallejos, G.; Ponce Caballero, C.

    2009-01-01

    Among the different kinds of bio aerosols, fungi represent a heterogeneous group, which plays an important role in human pathology. These microorganisms can be the cause of a variety of infectious diseases as well as allergic and toxic effects. Therefore, it is necessary to assess their composition and concentrations indoors, outdoors and in domestic environments. The study of indoor-air quality is a relatively new activity in the world, and very recent in Mexico. The aim of this study was to establish the relation between indoors and outdoors fungal aerosols in domestic homes. Air samples were collected, using the 6-stage Andersen impactor, inside and outside thirty domestic homes of Merida city, in Yucatan, Mexico. (Author)

  2. Magnitude of indoor NO{sub 2} from biomass fuels in rural settings of Ethiopia

    Energy Technology Data Exchange (ETDEWEB)

    Kumie, A.; Ali, A.; Mekonnen, E. (Addis Ababa Univ., Medical Faculty (Ethiopia)); Emmelin, A.; Wahlberg, S.; Brandstrom, D. (Umeaa Univ., Umeaa Int. School of Public Health (Sweden)); Berhane, Y. (Addis Continental Inst. of Public Health, Addis Ababa (Ethiopia))

    2009-02-15

    Half of the world's population and about 80% of households in Sub-Saharan Africa depend on biomass fuels. Indoor air pollution due to biomass fuel combustion may constitute a major public health threat affecting children and women. The purpose of this study was to measure levels of indoor NO{sub 2} concentration in homes with under-five children in rural Ethiopia. The study was undertaken in the Butajira area in Ethiopia from March 2000 to April 2002. 24-h samples were taken regularly at about three month intervals in approximately 3300 homes. Indoor air sampling was done using a modified Willems badge. For each sample taken, an interview with the mother of the child was performed. A Saltzman colorimetric method using a spectrometer calibrated at 540 nm was employed to analyze the mass of NO{sub 2} in field samples. Wood, crop residues and animal dung were the main household fuels. The mean (s.d.) 24-h concentration of NO{sub 2} was 97 mug/m3 (91.4). This is more than double the currently proposed annual mean of WHO air quality guideline. Highland households had significantly higher indoor NO{sub 2} concentration. This study demonstrates high levels of indoor NO{sub 2} in rural homes of Ethiopia. (au)

  3. Implications of chiral signatures of PCBs in soil, outdoor, and indoor air in the West Midlands conurbation, UK

    Energy Technology Data Exchange (ETDEWEB)

    Jamshidi, A.; Hazrati, S.; Harrad, S. [Birmigham Univ., Birmingham (United Kingdom)

    2005-07-01

    This paper provided additional data related to a study conducted to determine chiral signatures of polychlorinated biphenyl (PCBs) in outdoor air and topsoil from urban, rural and semi-urban locations in the United Kingdom's West Midlands conurbation. The study hypothesized that the ventilation of PCB-contaminated indoor air was a principal source of the racemic PCBs observed in outdoor air. Measurements of chiral signatures of PCBs in indoor air were measured. Chiral signatures of PCB 136 and 149 were expressed in terms of enantiomeric excess. Outdoor air and soil samples were collected from 10 sites located on a southwest to northeast transect of the conurbation at intervals of between 3 and 17 km. Topsoil and air samples were collected on a monthly basis to examine seasonal variability. Passive air samplers were used to provide a time-integrated atmospheric signal over each sampling period. Twenty indoor air samples were collected using PUF disk samplers. All samples were then extracted, purified, and subjected to enantioselective gas chromatography and mass spectrometry (GC-MS) analysis. Results suggested that chiral signatures in outdoor air for all target PCBs were racemic at all locations, and confirmed earlier hypotheses that the ventilation of PCB-contaminated indoor air is the principal source of PCB contamination in the urban atmosphere. It was concluded that actions to reduce PCB stocks remaining in use in indoor environments will result in a significant reduction in atmospheric concentrations. 7 refs., 2 tabs., 1 fig.

  4. PORK CARCASS COMPOSITION AND THE MEAT QUALITY OF THE BLACK SLAVONIAN PIG – THE ENDANGERED BREEDS IN THE INDOOR AND OUTDOOR KEEPING SYSTEM

    Directory of Open Access Journals (Sweden)

    Danijela Butko

    2007-06-01

    Full Text Available The research has been made on 20 Black Slavonian Pigs in both ways of keeping them (indoor, outdoor. The pigs have been fed up to 135 kg body weight. The pigs in the outdoor system have been held on a natural pasture ground. Other than pasture, the pigs have consumed, over the summer period, the food offered on stubble-fields after the harvest (barley, wheat and over the winter times after corn harvest. They had only minimal corn consumption; mostly during the winter (average daily consumption was 0.15 kg. Dissection of cold (+40C right sided pig body composition has been made by the modified Weniger et al (1963 method. The meat quality has been determined on a long back muscle sample (musculus longissimus dorsi- MLD taken berween 13th and 14th rib. The pig carcasses in the outdoor system had a very significant (P<0.01 absolute and relative leg share, less belly-rib share and higher meat quantity. Commercially, more valuable parts-legs and back had a greater share of muscle tissue in pigs' carcasses in the outdoor system. The meat of the pigs in the outdoor system had no signifficant differences from the pigs in the indoor system, concerning the pH1, pH2, water holding capacity, colour and marbling. However, the meat of the pigs in the outdoor system had higher content of crude fat from the pigs in the indoor system.

  5. The modifying effect of the building envelope on population exposure to PM2.5 from outdoor sources

    Science.gov (United States)

    Taylor, J; Shrubsole, C; Davies, M; Biddulph, P; Das, P; Hamilton, I; Vardoulakis, S; Mavrogianni, A; Jones, B; Oikonomou, E

    2014-01-01

    A number of studies have estimated population exposure to PM2.5 by examining modeled or measured outdoor PM2.5 levels. However, few have taken into account the mediating effects of building characteristics on the ingress of PM2.5 from outdoor sources and its impact on population exposure in the indoor domestic environment. This study describes how building simulation can be used to determine the indoor concentration of outdoor-sourced pollution for different housing typologies and how the results can be mapped using building stock models and Geographical Information Systems software to demonstrate the modifying effect of dwellings on occupant exposure to PM2.5 across London. Building archetypes broadly representative of those in the Greater London Authority were simulated for pollution infiltration using EnergyPlus. In addition, the influence of occupant behavior on indoor levels of PM2.5 from outdoor sources was examined using a temperature-dependent window-opening scenario. Results demonstrate a range of I/O ratios of PM2.5, with detached and semi-detached dwellings most vulnerable to high levels of infiltration. When the results are mapped, central London shows lower I/O ratios of PM2.5 compared with outer London, an apparent inversion of exposure most likely caused by the prevalence of flats rather than detached or semi-detached properties. PMID:24713025

  6. Microbiological Indoor and Outdoor Air Quality of Two Major ...

    African Journals Online (AJOL)

    Both indoor and outdoor air samples were assessed monthly for the three (3) months in the wet season (June – August, 2010) and dry season (November 2010 - January 2011) using the settled plate methods. The study sites were divided into nine (9) units which include accident and emergency ward, laboratory, male ward ...

  7. VOC source identification from personal and residential indoor, outdoor and workplace microenvironment samples in EXPOLIS-Helsinki, Finland

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Rufus D. [KTL-Finnish National Inst. of Public Health, Dept. of Environmental Hygiene, Kuopio (Finland); California Univ., School of Public Health, Berkeley, CA (United States); Jurvelin, J. [KTL-Finnish National Inst. of Public Health, Dept. of Environmental Hygiene, Kuopio (Finland); Jyvaeskylae Polytechnic, School of Engineering and Technology, Jyvaeskylae (Finland); Koistinen, K. [KTL-Finnish National Inst. of Public Health, Dept. of Environmental Hygiene, Kuopio (Finland); Saarela, K. [VTT, Chemical Technology, Espoo (Finland); Jantunen, M. [EC JRC, Inst. of the Environment, Ispra (Italy)

    2001-07-01

    Principal component analyses (varimax rotation) were used to identify common sources of 30 target volatile organic compounds (VOCs) in residential outdoor, residential indoor and workplace microenvironment and personal 48-h exposure samples, as a component of the EXPOLIS-Helsinki study. Variability in VOC concentrations in residential outdoor microenvironments was dominated by compounds associated with long-range transport of pollutants, followed by traffic emissions, emissions from trees and product emissions. Variability in VOC concentrations in environmental tobacco smoke (ETS) free residential indoor environments was dominated by compounds associated with indoor cleaning products, followed by compounds associated with traffic emissions, long-range transport of pollutants and product emissions. Median indoor/outdoor ratios for compounds typically associated with traffic emissions and long-range transport of pollutants exceeded 1, in some cases quite considerably, indicating substantial indoor source contributions. Changes in the median indoor/outdoor ratios during different seasons reflected different seasonal ventilation patterns as increased ventilation led to dilution of those VOC compounds in the indoor environment that had indoor sources. Variability in workplace VOC concentrations was dominated by compounds associated with traffic emissions followed by product emissions, long-range transport and air fresheners. Variability in VOC concentrations in ETS free personal exposure samples was dominated by compounds associated with traffic emissions, followed by long-range transport, cleaning products and product emissions. VOC sources in personal exposure samples reflected the times spent in different microenvironments, and personal exposure samples were not adequately represented by any one microenvironment, demonstrating the need for personal exposure sampling. (Author)

  8. Relationship of Indoor and Outdoor Air Pollutants in a Naturally Ventilated Historical Building Envelope

    Czech Academy of Sciences Publication Activity Database

    López-Aparicio, S.; Smolík, Jiří; Mašková, Ludmila; Součková, M.; Grøntoft, T.; Ondráčková, Lucie; Stankiewicz, J.

    2011-01-01

    Roč. 46, č. 7 (2011), s. 1460-1468 ISSN 0360-1323 Grant - others:MF NF(CZ) A/CZ0046/2/0001 Institutional research plan: CEZ:AV0Z40720504 Keywords : indoor/outdoor ration * natural ventilation * ammonia Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.400, year: 2011

  9. Personal exposure to PM2,5, black smoke and NO2 in Copenhagen: relationship to bedroom and outdoor concentrations covering seasonal variation

    DEFF Research Database (Denmark)

    Sørensen, M.; Loft, S.; Andersen, H. V.

    2005-01-01

    concentrations of PM(2.5), black smoke (BS), and nitrogen dioxide (NO(2)) were measured during 2-day periods in 30 subjects (20-33 years old) living and studying in central parts of Copenhagen. The measurements were repeated in the four seasons. Information on indoor exposure sources such as environmental......Epidemiological studies have found negative associations between human health and particulate matter in urban air. In most studies outdoor monitoring of urban background has been used to assess exposure. In a field study, personal exposure as well as bedroom, front door and background...

  10. Fighting against indoor pollution; Comment lutter contre la pollution interieure des locaux?

    Energy Technology Data Exchange (ETDEWEB)

    Pauli, G.; Blay, F. de; Krieger, P.; Bessot, J.C. [Hopitaux Universitaires de Strasbourg, 67 (France)

    1998-06-01

    Two types of indoor pollution have been identified: chemical pollution and biological pollution. The principal chemical pollutants are NO{sub 2}, VOCs (volatile organic compounds and formaldehyde), ozone and SO{sub 2}. Indoor NO{sub 2} is essentially produced by gas-heaters, stoves and fire-places, at levels that can be higher than those reached outdoors. Epidemiologic studies and NO{sub 2} provocation tests in asthmatics show that indoor NO{sub 2} is capable of triggering asthma either by direct effect or by potentiating bronchial reactivity to allergens. VOCs and formaldehyde are liberated by urea-formol foams and will only have bronchial effects at levels rarely found in domestic environment. Ozone is an outdoor pollutant essentially, and the concentrations found indoors do not exceed 50% of those measured outdoors. Concentration of SO{sub 2} can reach significant levels with the use of coal heaters, yet bronchial response will only be induced at levels rarely found indoors. The first way to fight against those pollutants is to eliminate their sources (gas, coal or kerosene heaters), and to increase ventilation. In contrast, as far as ozone is concerned, it is recommended to keep windows shot during summer pollution peaks, in order to prevent it from entering the home. Biological pollution -if we except endotoxins- is mainly represented by allergenic pollution: allergens of mites, pets, cockroaches, moulds... As far as mites are concerned, the different measures suggested should often be combined: they are methods to reduce relative humidity by increasing ventilation, physical methods consisting in eliminating textiles, vacuum cleaning, using anti-mite bed covers, and chemical methods (acaricides, tannic acid..). Palliative measures are possible. For example for cat allergen: humidification of fur, limiting secondary textile reservoirs, use of vacuum cleaners and air purifiers fitted with HEPA filters. As far as cockroaches are concerned, their eviction is

  11. Radon Concentration in Outdoors and Indoors Around the Flare in Oil Mine Sites

    International Nuclear Information System (INIS)

    Sutarman; Wahyudi; Luhantara

    2003-01-01

    The flares are much found at the oil exploration areas which appear the combustion gases emission to the environment that pass through a pipe at about 8 m high from the ground level. The flare is released into the environment together with the hydrocarbon and radon gases. This study has been carried out the measurement of the radon gas concentration only. Radon is a radioactive gas which comes from the natural radioactive decay of uranium ( 238 U). The outdoor radon concentrations were measured in 23 locations with the two-filter method. The locations were determined by a circle which the flare as the point center. The outdoor radon concentrations were measured in 74 houses (more than distance of 600 m from the flare) with the alpha track detector (CR-39) placed in the living rooms for about three months. The measurements of the radon concentrations were carried out in Cepu, Cirebon, and Prabumulih oil mine sites. The results showed that the outdoor radon concentrations a range of 108 Bq/m 3 to 256 Bq/m 3 in Cepu, 248 Bq/m 3 to 3525 Bq/m 3 in Cirebon, and 51 Bq/m 3 to 114 Bq/m 3 in Prabumulih. The results showed that the indoor radon concentrations a range of 11 Bq/m 3 to 38 Bq/m 3 in Cepu, 28 Bq/m 3 to 184 Bq/m 3 in Cirebon, and 12 Bq/m 3 to 38 Bq/m 3 in Prabumulih. The data of the maximum radon concentration in outdoor air was higher than an actual level which recommended by International Atomic Energy Agency (IAEA) for workplaces. The maximum radon concentration in indoor air was lower than an actual level which recommended by IAEA for dwellings. IAEA recommends the actual level of 1000 Bq/m 3 for workplaces and 200 Bq/m 3 for dwellings. These data will be used for the baseline data of the environmental radioactivity in Indonesia. (author)

  12. Evaluation of VOC concentrations in indoor and outdoor microenvironments at near-road schools.

    Science.gov (United States)

    Raysoni, Amit U; Stock, Thomas H; Sarnat, Jeremy A; Chavez, Mayra C; Sarnat, Stefanie Ebelt; Montoya, Teresa; Holguin, Fernando; Li, Wen-Whai

    2017-12-01

    A 14-week air quality study, characterizing the indoor and outdoor concentrations of 18 VOCs at four El Paso, Texas elementary schools, was conducted in Spring 2010. Three schools were in an area of high traffic density and the fourth school, considered as a background school, was situated in an area affected minimally by stationary and mobile sources of air pollution. Passive samplers were deployed for monitoring and analyzed by GC/MS. Differences in the concentration profiles of the BTEX species between the high and low traffic density schools confirmed the pre-defined exposure patterns. Toluene was the predominant compound within the BTEX group and the 96-hr average outdoor concentrations varied from 1.16 to 4.25 μg/m 3 across the four schools. Outdoor BTEX species were strongly correlated with each other (0.63 schools in contrast to the low-exposure school. This was further corroborated by the results obtained from the BTEX inter-species ratios (toluene: benzene and m, p- xylenes: ethylbenzene). Certain episodic events during the study period resulted in very elevated concentrations of some VOCs such as n-pentane. Indoor concentration of compounds with known indoor sources such as α -pinene, d-limonene, p-dichlorobenzene, and chloroform were generally higher than their corresponding outdoor concentrations. Cleaning agents, furniture polishes, materials used in arts and crafts activities, hot-water usage, and deodorizing cakes used in urinal pots were the likely major sources for these high indoor concentrations. Finally, retrospective assessment of average ambient BTEX concentrations over the last twenty years suggest a gradual decrement in this border region. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. [Measurement of Chemical Compounds in Indoor and Outdoor Air in Chiba City Using Diffusive Sampling Devices].

    Science.gov (United States)

    Sakamoto, Hironari; Uchiyama, Shigehisa; Kihara, Akiko; Tsutake, Toyoshige; Bekki, Kanae; Inaba, Yohei; Nakagome, Hideki; Kunugita, Naoki

    2015-01-01

    Indoor air quality (IAQ) is a major concern, because people on average spend the vast majority of their time indoors and they are repeatedly exposed to indoor air pollutants. In this study, to assess indoor air quality in Chiba City, gaseous chemical compounds were surveyed using four types of diffusive sampler. Gaseous chemical compounds such as carbonyls, volatile organic compounds (VOC), acid gases, basic gases, and ozone were measured in indoor and outdoor air of 50 houses throughout Chiba City in winter and summer. Four types of diffusive sampler were used in this study: DSD-BPE/DNPH packed with 2,4-dinitrophenyl hydrazine and trans-1,2-bis(2-pyridyl)ethylene-coated silica for ozone and carbonyls; VOC-SD packed with Carboxen 564 particles for volatile organic compounds; DSD-TEA packed with triethanolamine-impregnated silica for acid gases; and DSD-NH3 packed with phosphoric acid-impregnated silica for basic gases. Almost all compounds in indoor air were detected at higher concentrations in summer than in winter. However, the nitrogen dioxide concentration in indoor air particularly increased only in winter, which well correlated with the formic acid concentration (correlation coefficient=0.974). The compound with the highest concentrations in indoor air was p-dichlorobenzene, with recorded levels of 13,000 μg m(-3) in summer and 1,100 μg m(-3) in winter in indoor air. p-Dichlorobenzene in summer and nitrogen dioxide in winter are detected at markedly high concentrations. Pollution control and continuous monitoring of IAQ are indispensable for human health.

  14. Indoor-outdoor concentrations of RSPM in classroom of a naturally ventilated school building near an urban traffic roadway

    Science.gov (United States)

    Goyal, Radha; Khare, Mukesh

    2009-12-01

    A study on indoor-outdoor RSPM (PM 10, PM 2.5 and PM 1.0) mass concentration monitoring has been carried out at a classroom of a naturally ventilated school building located near an urban roadway in Delhi City. The monitoring has been planned for a year starting from August 2006 till August 2007, including weekdays (Monday, Wednesday and Friday) and weekends (Saturday and Sunday) from 8:0 a.m. to 2:0 p.m., in order to take into account hourly, daily, weekly, monthly and seasonal variations in pollutant concentrations. Meteorological parameters, including temperature, rH, pressure, wind speed and direction, and traffic parameters, including its type and volume has been monitored simultaneously to relate the concentrations of indoor-outdoor RSPM with them. Ventilation rate has also been estimated to find out its relation with indoor particulate concentrations. The results of the study indicates that RSPM concentrations in classroom exceeds the permissible limits during all monitoring hours of weekdays and weekends in all seasons that may cause potential health hazards to occupants, when exposed. I/O for all sizes of particulates are greater than 1, which implies that building envelop does not provide protection from outdoor pollutants. Further, a significant influence of meteorological parameters, ventilation rate and of traffic has been observed on I/O. Higher I/O for PM 10 is indicating the presence of its indoor sources in classroom and their indoor concentrations are strongly influenced by activities of occupants during weekdays.

  15. COMPARISON OF INDOOR AIR QUALITY IN RESTAURANT KITCHENS IN TEHRAN WITH AMBIENT AIR QUALITY

    Directory of Open Access Journals (Sweden)

    M. Ghasemkhani, F. Naseri

    2008-01-01

    Full Text Available The indoor air quality of 131 restaurant kitchens in Tehran was investigated from May to September 2006. Gas stoves use in restaurant kitchens is a major source of indoor combustion, product carbon monoxide and nitrogen dioxide. The study focused on one of the busy zones located in the southwest and central part of the city. Measurements were done for indoor and outdoor air pollutants, carbon monoxide and nitrogen dioxide; ambient temperature and relative humidity were also measured. Result indicated that the mean levels of CO and NO2 in restaurant kitchens were below the recommended limit of 25 and 3ppm, respectively. Correlations between indoor and outdoor air quality were performed consequently. Results of the mean ambient temperature and relative humidity were above the guideline. In this study the mean levels of CO and NO2 gas cooking in restaurant kitchens were found to be lower compared with the similar studies.

  16. Comparative fly species composition on indoor and outdoor forensic cases in Malaysia.

    Science.gov (United States)

    Syamsa, Rizal Abdullah; Omar, Baharudin; Ahmad, Firdaus Mohd Salleh; Hidayatulfathi, Othman; Shahrom, Abd Wahid

    2017-01-01

    Forensic entomology refers to the science of collection and analysis of insect evidence in order to determine the minimum time period since death. This study aimed to investigate the occurrence of forensically important flies on 34 human remains referred to Universiti Kebangsaan Malaysia Medical Centre over a period of three years. Entomological specimens were collected at the death scenes and/or during autopsies. Live specimens were reared into adults while preserved specimens were processed for species identification. Five families, seven genera and nine species of flies were identified from human remains. The results of the study showed Chrysomya megacephala (Calliphoridae) maggots occurred on corpses with the highest frequency (70.6%), followed by Ch. rufifacies (Calliphoridae) (44.1%), sarcophagid fly (Sarcophagidae) (38.2%), Synthesiomya nudiseta (Muscidae) (20.6%), Megaselia scalaris (Phoridae) (14.7%), Lucilia cuprina (Calliphoridae) (5.9%), Ch. nigripes (Calliphoridae) (5.9%), Eristalis spp. (Syrphidae) (5.9%) and Hydrotaea spinigera (Muscidae) (2.9%). The greatest fly diversity occurred on remains recovered indoors (eight species) compared to outdoors (three species). Whilst, single and double infestations were common for both indoor and outdoor cases, multiple infestation of up to six species was observed in one of the indoor cases. Although large numbers of fly species were found on human remains, the predominant species were still those of Chrysomya, while S. nudiseta was found only on human remains recovered from indoors. The present study provides additional knowledge in the context of Malaysian forensic entomology and the distribution of forensically important flies which is of relevance to forensic science. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  17. Indoor air pollution (PM2.5) due to secondhand smoke in selected hospitality and entertainment venues of Karachi, Pakistan.

    Science.gov (United States)

    Nafees, Asaad Ahmed; Taj, Tahir; Kadir, Muhammad Masood; Fatmi, Zafar; Lee, Kiyoung; Sathiakumar, Nalini

    2012-09-01

    To determine particulate matter smaller than 2.5 μm (PM(2.5)) levels at various hospitality and entertainment venues of Karachi, Pakistan. This was a descriptive cross-sectional study conducted at various locations in Karachi, during July 2009. Sampling was performed at 20 enclosed public places, including hospitality (restaurants and cafés) and entertainment (snooker/billiard clubs and gaming zones) venues. PM(2.5) levels were measured using an aerosol monitor. All entertainment venues had higher indoor PM(2.5) levels as compared to the immediate outdoors. The indoor PM(2.5) levels ranged from 25 to 390 μg/m(3) and the outdoor PM(2.5) levels ranged from 18 to 96 μg/m(3). The overall mean indoor PM(2.5) level was 138.8 μg/m(3) (± 112.8). Among the four types of venues, the highest mean indoor PM(2.5) level was reported from snooker/billiard clubs: 264.7 μg/m(3) (± 85.4) and the lowest from restaurants: 66.4 μg/m(3) (± 57.6) while the indoor/outdoor ratio ranged from 0.97 to 10.2, highest being at the snooker/billiard clubs. The smoking density ranged from 0.21 to 0.57, highest being at gaming zones. The indoor PM(2.5) concentration and smoking density were not significantly correlated (Spearman's correlation coefficient = 0.113; p = 0.636). This study demonstrates unacceptably high levels of PM(2.5) exposure associated with secondhand smoke (SHS) at various entertainment venues of Karachi even after 8 years since the promulgation of smoke-free ordinance (2002) in Pakistan; however, better compliance may be evident at hospitality venues. The results of this study call for effective implementation and enforcement of smoke-free environment at public places in the country.

  18. A survey of perfluoroalkyl sulfonamides in indoor and outdoor air using passive air samplers

    Energy Technology Data Exchange (ETDEWEB)

    Shoeib, M.; Harner, T. [Meteorological Service of Canada, Environment Canada (Canada); Wilford, B.; Jones, K. [Lancaster Univ. (United Kingdom). Environmental Science; Zhu, J. [Chemistry Research Division, Health Canada, Tunney' s Pasture, Ottawa (Canada)

    2004-09-15

    Perfluorooctane sulfonate (PFOS) has recently emerged as a priority environmental pollutant due to its widespread detection in biological samples from remote regions including the Arctic and the Mid-North Pacific Ocean. Because PFOS is fairly involatile, it is hypothesized that its occurrence in remote regions is the result of atmospheric transport of more volatile precursor compounds such as the perfluoroalkyl sulfonamides (PFASs). PFASs are used in variety of consumer products for water and oil resistance including surface treatments for fabric, upholstery, carpet, paper and leather. In a recent pilot study employing high volume air samples, indoor air concentrations of PFASs were approximately 100 times greater than outdoor levels. This is of significance because people typically spend about 90% of their time indoors 5 and this exposure may serve as an important uptake pathway. Indoor air also serves as a source of PFASs to the outside where PFASs are ultimately transported and distributed throughout the environment. The current study is intended to be a more comprehensive survey of indoor and outdoor air allowing more confident conclusions to be made. Passive air samplers comprised of polyurethane foam (PUF) disks were used. These are quiet, non-intrusive samplers that operate without the aid of a pump or electricity. Air movement delivers chemical to the sampler which has a high retention capacity for persistent organic pollutants (POPs). PUF disks samplers have been previously used successfully to monitor different classes of hydrophobic persistent organic pollutants POPs.

  19. Unusually amplified summer or winter indoor levels of radon

    International Nuclear Information System (INIS)

    Gammage, R.B.; Dudney, C.S.; Wilson, D.L.

    1993-01-01

    The ratios of winter/summer indoor radon levels for houses in different regions of the southern Appalachians are characterized by individual log-normal distributions with geometric means both above and below unity. In some counties and cities, subpopulations of houses have unusually exaggerated winter/summer ratios of indoor radon, as well as high indoor radon levels, during periods of either warm or cool weather. It is proposed that in many instances, houses are communicating with larger than normal underground reservoirs of radon-bearing air in hilly karst terrains; differences between the outdoor and underground air temperatures are believed to provide density gradients producing aerostatic pressure differences for seasonally directed underground transport and subsequently elevated indoor radon. These seasonal movements of air are analogous to the well-known underground chimney effects, which produce interzonal flows of air inside caves

  20. Outdoor and indoor dose assessment using environmental thermoluminescence dosimeters (TLDs) in Costa Rica

    International Nuclear Information System (INIS)

    Mora, Patricia

    2003-01-01

    Costa Rica lies at the intersection of the Cocos and Caribbean plates in Central America. It has mountain ranges with many active volcanoes along its territory. Its soils are predominantly of volcanic origin. Natural radiation measurements utilising environmental CaF 2 :Dy thermoluminescence dosimeters were used for the first time in Costa Rica by the Dosimetry Section of the Atomic, Nuclear and Molecular Sciences Research Center of the University of Costa Rica. Seven hundred outdoor measurements were obtained in a 3.5-year period at eight different sites throughout the country. One hundred and seventy-four indoor readings were also collected at four sites for a 2-year period. Population-weighted averages give 82 nGy h -1 for outdoors and 130 nGy h -1 for indoors. The values lie on the upper range of worldwide reported values due to reported soil characteristics rich in uranium and potassium. A preliminary population-weighted value of 0.74 mSv/year for the effective dose is calculated for natural terrestrial gamma radiation in Costa Rica

  1. i-Locate - Indoor/Outdoor location and Asset Management through Open Data

    Directory of Open Access Journals (Sweden)

    Claudio Eccher

    2015-02-01

    Full Text Available Studi recenti hanno evidenziato che, in media, trascorriamo circa il 90% del nostro tempo in ambienti chiusi e, spesso, non familiari. L’esigenza di localizzare/guidare persone o ogg etti in spazi sia esterni che interni (senza discontinuità tra esterno ed interno darà origine ad una serie di nuovi servizi di tipo LBS (Location-Based Services che potranno avere anche una notevole rilevanza economica. i-locate (Indoor / outdoor location and Asset Management Through open geodata is a project that aims to develop a set of tools and services based on geo location technologies based on open data for the location and management of objects in indoor and outdoor spaces. The tools are intended both to citizens who use their smartphones to access services, aids to navigation from the front door to internal destinations to buildings (public office, clinic, shop, etc.. Obtaining any information available to support (code , unforeseen changes in the path, suggestions, etc., and professionals for specific activities that require the location of people, equipment, etc. i-locate to an intense use of GIS technologies for navigation and tracking "indoor" (indoor GIS, 3D GIS, to locate people (eg. Alzheimer's patients and their movements in areas not suited (geofencing to identify and track objects / portable equipment for their location, management and maintenance.

  2. i-Locate - Indoor/Outdoor location and Asset Management through Open Data

    Directory of Open Access Journals (Sweden)

    Claudio Eccher

    2015-02-01

    Full Text Available Studi recenti hanno evidenziato che, in media, trascorriamo circa il 90% del nostro tempo in ambienti chiusi e, spesso, non familiari. L’esigenza di localizzare/guidare persone o ogg etti in spazi sia esterni che interni (senza discontinuità tra esterno ed interno darà origine ad una serie di nuovi servizi di tipo LBS (Location-Based Services che potranno avere anche una notevole rilevanza economica.i-locate (Indoor / outdoor location and Asset Management Through open geodata is a project that aims to develop a set of tools and services based on geo location technologies based on open data for the location and management of objects in indoor and outdoor spaces. The tools are intended both to citizens who use their smartphones to access services, aids to navigation from the front door to internal destinations to buildings (public office, clinic, shop, etc.. Obtaining any information available to support (code , unforeseen changes in the path, suggestions, etc., and professionals for specific activities that require the location of people, equipment, etc. i-locate to an intense use of GIS technologies for navigation and tracking "indoor" (indoor GIS, 3D GIS, to locate people (eg. Alzheimer's patients and their movements in areas not suited (geofencing to identify and track objects / portable equipment for their location, management and maintenance.

  3. Integrated algorithms for RFID-based multi-sensor indoor/outdoor positioning solutions

    Science.gov (United States)

    Zhu, Mi.; Retscher, G.; Zhang, K.

    2011-12-01

    Position information is very important as people need it almost everywhere all the time. However, it is a challenging task to provide precise positions indoor/outdoor seamlessly. Outdoor positioning has been widely studied and accurate positions can usually be achieved by well developed GPS techniques but these techniques are difficult to be used indoors since GPS signal reception is limited. The alternative techniques that can be used for indoor positioning include, to name a few, Wireless Local Area Network (WLAN), bluetooth and Ultra Wideband (UWB) etc.. However, all of these have limitations. The main objectives of this paper are to investigate and develop algorithms for a low-cost and portable indoor personal positioning system using Radio Frequency Identification (RFID) and its integration with other positioning systems. An RFID system consists of three components, namely a control unit, an interrogator and a transponder that transmits data and communicates with the reader. An RFID tag can be incorporated into a product, animal or person for the purpose of identification and tracking using radio waves. In general, for RFID positioning in urban and indoor environments three different methods can be used, including cellular positioning, trilateration and location fingerprinting. In addition, the integration of RFID with other technologies is also discussed in this paper. A typical combination is to integrate RFID with relative positioning technologies such as MEMS INS to bridge the gaps between RFID tags for continuous positioning applications. Experiments are shown to demonstrate the improvements of integrating multiple sensors with RFID which can be employed successfully for personal positioning.

  4. Development of Indoor Air Pollution Concentration Prediction by Geospatial Analysis

    Directory of Open Access Journals (Sweden)

    Adyati Pradini Yudison

    2015-07-01

    Full Text Available People living near busy roads are potentially exposed to traffic-induced air pollutants. The pollutants may intrude into the indoor environment, causing health risks to the occupants. Prediction of pollutant exposure therefore is of great importance for impact assessment and policy making related to environmentally sustainable transport. This study involved the selection of spatial interpolation methods that can be used for prediction of indoor air quality based on outdoor pollutant mapping without indoor measurement data. The research was undertaken in the densely populated area of Karees, Bandung, Indonesia. The air pollutant NO2 was monitored in this area as a preliminary study. Nitrogen dioxide concentrations were measured by passive diffusion tube. Outdoor NO2 concentrations were measured at 94 locations, consisting of 30 roadside and 64 outdoor locations. Residential indoor NO2 concentrations were measured at 64 locations. To obtain a spatially continuous air quality map, the spatial interpolation methods of inverse distance weighting (IDW and Kriging were applied. Selection of interpolation method was done based on the smallest root mean square error (RMSE and standard deviation (SD. The most appropriate interpolation method for outdoor NO2 concentration mapping was Kriging with an SD value of 5.45 µg/m3 and an RMSE value of 5.45 µg/m3, while for indoor NO2 concentration mapping the IDW was best fitted with an RMSE value of 5.92 µg/m3 and an SD value of 5.92 µg/m3.

  5. Relationship of Indoor, Outdoor and Personal Air (RIOPA) study: study design, methods and quality assurance/control results.

    Science.gov (United States)

    Weisel, Clifford P; Zhang, Junfeng; Turpin, Barbara J; Morandi, Maria T; Colome, Steven; Stock, Thomas H; Spektor, Dalia M; Korn, Leo; Winer, Arthur; Alimokhtari, Shahnaz; Kwon, Jaymin; Mohan, Krishnan; Harrington, Robert; Giovanetti, Robert; Cui, William; Afshar, Masoud; Maberti, Silvia; Shendell, Derek

    2005-03-01

    The Relationship of Indoor, Outdoor and Personal Air (RIOPA) Study was undertaken to evaluate the contribution of outdoor sources of air toxics, as defined in the 1990 Clean Air Act Amendments, to indoor concentrations and personal exposures. The concentrations of 18 volatile organic compounds (VOCs), 17 carbonyl compounds, and fine particulate matter mass (PM(2.5)) were measured using 48-h outdoor, indoor and personal air samples collected simultaneously. PM2.5 mass, as well as several component species (elemental carbon, organic carbon, polyaromatic hydrocarbons and elemental analysis) were also measured; only PM(2.5) mass is reported here. Questionnaires were administered to characterize homes, neighborhoods and personal activities that might affect exposures. The air exchange rate was also measured in each home. Homes in close proximity (<0.5 km) to sources of air toxics were preferentially (2:1) selected for sampling. Approximately 100 non-smoking households in each of Elizabeth, NJ, Houston, TX, and Los Angeles, CA were sampled (100, 105, and 105 respectively) with second visits performed at 84, 93, and 81 homes in each city, respectively. VOC samples were collected at all homes, carbonyls at 90% and PM(2.5) at 60% of the homes. Personal samples were collected from nonsmoking adults and a portion of children living in the target homes. This manuscript provides the RIOPA study design and quality control and assurance data. The results from the RIOPA study can potentially provide information on the influence of ambient sources on indoor air concentrations and exposure for many air toxics and will furnish an opportunity to evaluate exposure models for these compounds.

  6. Number Concentrations and Modal Structure of Indoor/Outdoor Fine Particles in Four European Cities.

    Czech Academy of Sciences Publication Activity Database

    Lazaridis, M.; Eleftheriadis, K.; Ždímal, Vladimír; Schwarz, Jaroslav; Wagner, Zdeněk; Ondráček, Jakub; Drossinos, Y.; Glytsos, T.; Vratolis, S.; Torseth, K.; Moravec, Pavel; Hussein, T.; Smolík, Jiří

    2017-01-01

    Roč. 17, č. 1 (2017), s. 131-146 ISSN 1680-8584 EU Projects: European Commission(XE) 315760 - HEXACOMM Institutional support: RVO:67985858 Keywords : indoor/outdoor aerosol * I/O ratio * modal structure Subject RIV: DG - Athmosphere Sciences, Meteorology OBOR OECD: Meteorology and atmospheric sciences Impact factor: 2.606, year: 2016

  7. Impact of intentionally introduced sources on indoor VOC levels

    Energy Technology Data Exchange (ETDEWEB)

    Davis, C.S. [BOVAR Environmental, Downsview, Ontario (Canada); Otson, R. [Health Canada, Ottawa, Ontario (Canada). Environmental Health Centre

    1997-12-31

    The concentrations of 33 target volatile organic compounds (VOC) were measured in outdoor air and in indoor air before and after the introduction of dry-cleaned clothes, and consumer products into two suburban homes. Emissions from the household products (air fresheners, furniture polishes, mothballs, and dry-cleaned clothes), showering, and two paints were analyzed to obtain source profiles. There were measurable increases in the 24 h average concentrations for 10 compounds in one house and 8 compounds in the second house after introduction of the sources. A contribution by showering to indoor VOC was not evident although the impact of the other sources and outdoor air could be discerned, based on results for the major constituents of source emissions. Also, contributions by paints, applied three to six weeks prior to the monitoring, to indoor VOC concentrations were evident. The pattern of concentrations indicated that sink effects need to be considered in explaining the indoor concentrations that result when sources are introduced into homes. Quantitative estimates of the relative contributions of the sources to indoor VOC levels were not feasible through the use of chemical mass balance since the number of tracer species detected (up to 6) and that could be used for source apportionment was similar to the number of sources to be apportioned (up to 7).

  8. Investigation of time-resolved atmospheric conditions and indoor/outdoor particulate matter concentrations in homes with gas and biomass cook stoves in Nogales, Sonora, Mexico.

    Science.gov (United States)

    Holmes, Heather A; Pardyjak, Eric R

    2014-07-01

    ambient air measurements. However, a large fraction of time is typically spent indoors where a variety of activities including cooking, heating, tobacco smoking, and cleaning can lead to elevated PM concentrations. This study investigates the influence of meteorology, outdoor PM, and indoor activities on indoor air pollution (IAP) levels in the United States-Mexico border region. Results indicate that cooking fuel type and meteorology greatly influence the IAP in homes, with biomass fuel use causing the largest increase in PM concentration.

  9. Seamless Indoor/Outdoor Positioning Handover for Location-Based Services in Streamspin

    DEFF Research Database (Denmark)

    Hansen, Rene; Wind, Rico; Jensen, Christian Søndergaard

    2009-01-01

    the delivery of truly ubiquitous location-based services by integrating GPS and Wi-Fi location fingerprinting. The paper puts focus on key aspects of the seamless handover between outdoor to indoor positioning. Several different handover solutions are presented,and their applicability is evaluated with respect...

  10. Asthma and asthma related symptoms in 23,326 Chinese children in relation to indoor and outdoor environmental factors: The Seven Northeastern Cities (SNEC) Study

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Fan, E-mail: liufan-sky@163.com [Department of Orthodontics, School of Stomatology, China Medical University, Shenyang, Liaoning Province 110001 (China); Zhao, Yang, E-mail: zhaoyang_cmu@126.com [Department of Biostatistics and Epidemiology, School of Public Health, China Medical University, Shenyang, Liaoning Province 110001 (China); Liu, Yu-Qin, E-mail: xinxin_lyq@163.com [Department of Biostatistics and Epidemiology, School of Public Health, China Medical University, Shenyang, Liaoning Province 110001 (China); Liu, Yang, E-mail: liuyang071506@126.com [Department of Biostatistics and Epidemiology, School of Public Health, China Medical University, Shenyang, Liaoning Province 110001 (China); Sun, Jing, E-mail: sunjingjl_2007@126.com [Department of Biostatistics and Epidemiology, School of Public Health, China Medical University, Shenyang, Liaoning Province 110001 (China); Huang, Mei-Meng, E-mail: gghuangmeimeng@163.com [Department of Biostatistics and Epidemiology, School of Public Health, China Medical University, Shenyang, Liaoning Province 110001 (China); Liu, Yi, E-mail: liuyi256@126.com [Department of Orthodontics, School of Stomatology, China Medical University, Shenyang, Liaoning Province 110001 (China); Dong, Guang-Hui, E-mail: donggh5@mail.sysu.edu.cn [Department of Preventive Medicine, School of Public Health, Sun Yat-sen University, Guangzhou, Guangdong Province 510080 (China)

    2014-11-01

    Background: Both the levels and patterns of outdoor and indoor air pollutants have changed dramatically during the last decade in China. However, few studies have evaluated the effects of the present air pollution on the health of Chinese children. This study examines the association between outdoor and indoor air pollution and respiratory diseases among children living in Liaoning, a heavy industrial province of China. Methods: A cross-sectional study of 23,326 Chinese children aged 6 to 13 years was conducted in 25 districts of 7 cities in Northeast China during 2009. Three-year (2006–2008) average concentrations of particles with an aerodynamic diameter of ≤ 10 μm (PM{sub 10}), sulfur dioxide (SO{sub 2}), nitrogen dioxides (NO{sub 2}), and ozone (O{sub 3}) were calculated from monitoring stations in each of the 25 districts. We used two-level logistic regression models to examine the effects of yearly variations in exposure to each pollutant, controlling for important covariates. Results: The prevalence of respiratory symptoms was higher for those dwelling close to a busy road, those living near smokestacks or factories, those living with smokers, those living in one-story houses typically with small yards, and those with home renovation, bedroom carpet or pets. Ventilation device use was associated with decreased odds of asthma in children. The adjusted odds ratio for diagnosed-asthma was 1.34 (95% confidence interval [CI], 1.24–1.45) per 31 μg/m{sup 3} increase in PM{sub 10}, 1.23 (95%CI, 1.14–1.32) per 21 μg/m{sup 3} increase in SO{sub 2}, 1.25 (95%CI, 1.16–1.36) per 10 μg/m{sup 3} increase in NO{sub 2}, and 1.31 (95%CI, 1.21–1.41) per 23 μg/m{sup 3} increase in O{sub 3}, respectively. Conclusion: Outdoor and indoor air pollution was associated with an increased likelihood of respiratory morbidity among Chinese children. - Highlights: • We studied air pollution and respiratory health in 23,326 Chinese children. • Home renovation, carpet

  11. Asthma and asthma related symptoms in 23,326 Chinese children in relation to indoor and outdoor environmental factors: The Seven Northeastern Cities (SNEC) Study

    International Nuclear Information System (INIS)

    Liu, Fan; Zhao, Yang; Liu, Yu-Qin; Liu, Yang; Sun, Jing; Huang, Mei-Meng; Liu, Yi; Dong, Guang-Hui

    2014-01-01

    Background: Both the levels and patterns of outdoor and indoor air pollutants have changed dramatically during the last decade in China. However, few studies have evaluated the effects of the present air pollution on the health of Chinese children. This study examines the association between outdoor and indoor air pollution and respiratory diseases among children living in Liaoning, a heavy industrial province of China. Methods: A cross-sectional study of 23,326 Chinese children aged 6 to 13 years was conducted in 25 districts of 7 cities in Northeast China during 2009. Three-year (2006–2008) average concentrations of particles with an aerodynamic diameter of ≤ 10 μm (PM 10 ), sulfur dioxide (SO 2 ), nitrogen dioxides (NO 2 ), and ozone (O 3 ) were calculated from monitoring stations in each of the 25 districts. We used two-level logistic regression models to examine the effects of yearly variations in exposure to each pollutant, controlling for important covariates. Results: The prevalence of respiratory symptoms was higher for those dwelling close to a busy road, those living near smokestacks or factories, those living with smokers, those living in one-story houses typically with small yards, and those with home renovation, bedroom carpet or pets. Ventilation device use was associated with decreased odds of asthma in children. The adjusted odds ratio for diagnosed-asthma was 1.34 (95% confidence interval [CI], 1.24–1.45) per 31 μg/m 3 increase in PM 10 , 1.23 (95%CI, 1.14–1.32) per 21 μg/m 3 increase in SO 2 , 1.25 (95%CI, 1.16–1.36) per 10 μg/m 3 increase in NO 2 , and 1.31 (95%CI, 1.21–1.41) per 23 μg/m 3 increase in O 3 , respectively. Conclusion: Outdoor and indoor air pollution was associated with an increased likelihood of respiratory morbidity among Chinese children. - Highlights: • We studied air pollution and respiratory health in 23,326 Chinese children. • Home renovation, carpet, and pet were associated with increased ORs of asthma

  12. INDOOR-OUTDOOR AEROSOL CONCENTRATIONS IN TWO PORTUGUESE CITIES AND THE GLOBAL WARMING SCENARIO

    Energy Technology Data Exchange (ETDEWEB)

    Antonio F. Miguel; A. Heitor Reis [Department of Physics, University of Evora (Portugal); Marta Melgao [Geophysics Centre of Evora (Portugal)

    2008-09-30

    Aerosols play a major role both in climate change and in air quality. They affect climate through interfering with radiative transfer and hence the atmospheric temperature, and also the air quality. Many epidemiological studies have confirmed that a relation exists between elevated aerosol particle concentration and adverse human health effects. Aerosol particle number and size distributions were measured both indoors and outdoors in the urban areas of Evora and Lisbon. We investigated the indoor-to-outdoor relationship of aerosol particles and the aerosol size distributions. The impact of the occurrence of a residential fire in the aerosol size distribution is also analyzed. Finally, we speculate of how global increase in temperature can affect concentration of aerosols in the atmosphere, via increased boundary layer convection.

  13. A pilot study using scripted ventilation conditions to identify key factors affecting indoor pollutant concentration and air exchange rate in a residence.

    Science.gov (United States)

    Johnson, Ted; Myers, Jeffrey; Kelly, Thomas; Wisbith, Anthony; Ollison, Will

    2004-01-01

    significant increase in the explained variance (R(2)-value) of the regression equations: AER, number and location of apertures, wind speed, air-conditioning operation, indoor temperature, outdoor temperature, and relative humidity. The indoor concentrations of CO, PAH, NO, and NO(x) were highly correlated with the corresponding outdoor concentrations. The indoor benzene concentrations showed only moderate correlation with outdoor benzene levels, possibly due to a weak indoor source. Indoor formaldehyde concentrations always exceeded outdoor levels, and the correlation between indoor and outdoor concentrations was not statistically significant, indicating the presence of a strong indoor source.

  14. Association of Roadway Proximity with Indoor Air Pollution in a Peri-Urban Community in Lima, Peru

    Directory of Open Access Journals (Sweden)

    Lindsay J. Underhill

    2015-10-01

    Full Text Available The influence of traffic-related air pollution on indoor residential exposure is not well characterized in homes with high natural ventilation in low-income countries. Additionally, domestic allergen exposure is unknown in such populations. We conducted a pilot study of 25 homes in peri-urban Lima, Peru to estimate the effects of roadway proximity and season on residential concentrations. Indoor and outdoor concentrations of particulate matter (PM2.5, nitrogen dioxide (NO2, and black carbon (BC were measured OPEN ACCESS Int. J. Environ. Res. Public Health 2015, 12 13467 during two seasons, and allergens were measured in bedroom dust. Allergen levels were highest for dust mite and mouse allergens, with concentrations above clinically relevant thresholds in over a quarter and half of all homes, respectively. Mean indoor and outdoor pollutant concentrations were similar (PM2.5: 20.0 vs. 16.9 μg/m3, BC: 7.6 vs. 8.1 μg/m3, NO2: 7.3 vs. 7.5 ppb, and tended to be higher in the summer compared to the winter. Road proximity was significantly correlated with overall concentrations of outdoor PM2.5 (rs = −0.42, p = 0.01 and NO2 (rs = −0.36, p = 0.03, and outdoor BC concentrations in the winter (rs = −0.51, p = 0.03. Our results suggest that outdoor-sourced pollutants significantly influence indoor air quality in peri-urban Peruvian communities, and homes closer to roadways are particularly vulnerable.

  15. Distribution of Gas Phase Polycyclic Aromatic Hydrocarbons (PAHs in Selected Indoor and Outdoor Air Samples of Malaysia: a Case Study in Serdang, Selangor and Bachang, Malacca

    Directory of Open Access Journals (Sweden)

    Haris Hafizal Abd Hamid

    2017-07-01

    Full Text Available Distribution of 10 polycyclic aromatic hydrocarbons (PAHs in the gas phase of air from selected indoor and outdoor areas of Selangor and Malacca, Malaysia has been investigated. A locally designed Semi Permeable Membrane Device (SPMD was applied for passive air sampling for 37 days at selected locations. Cleanup was carried out with Gas Purge - Micro Syringe Extraction (GP-MSE and the final analysis was using Gas Chromatography-Mass Spectrometry (GC-MS. In this study, 6 indoor and 12 outdoor locations were selected for air sampling. A total of 10 compounds of PAHs (Ʃ10PAHs were determined in the range of 0.218 ng/m3 - 1.692 ng/m3 and 0.378 ng/m3 - 1.492 ng/m3 in outdoor and indoor samples respectively. In the outdoor samples, locations such as near a petrol station and heavy traffic showed the maximum levels of Ʃ10PAHs, while rooftop samples showed the lowest Ʃ10PAHs. The distribution of gas phase Ʃ10PAHs was influenced by vehicular emission. Low molecular weight (LMW compounds (2-3 rings were dominant in all samples (>70% indicating that SPMD has successfully sampled the gas phase of the air.

  16. Indoor, outdoor, and personal exposure monitoring of particulate air pollution: the Baltimore elderly epidemiology-exposure pilot study

    Science.gov (United States)

    Williams, Ron; Creason, John; Zweidinger, Roy; Watts, Randall; Sheldon, Linda; Shy, Carl

    A 17-day pilot study investigating potential PM exposures of an elderly population was conducted near Baltimore, Maryland. Collection of residential indoor, residential outdoor, and ambient monitoring data associated with the subjects living at a common retirement facility was integrated with results from a paired epidemiological pilot study. This integration was used to investigate the potential pathophysiological health effects resulting from daily changes in estimated PM exposures with results reported elsewhere. Objectives of the exposure study were to determine the feasibility of performing PM exposure assessment upon an elderly population and establishing relationships between the various exposure measures including personal monitoring. PM 2.5 was determined to be the dominant outdoor size fraction (0.83 PM 2.5/PM 10 mass ratio by dichot monitoring). Individual 24-h PM 1.5 personal exposures ranged from 12 to 58 μg m -3. Comparison of data from matched sampling dates resulted in mean daily PM 1.5 personal, PM 2.5 outdoor, and PM 1.5 indoor concentrations of 34, 17, and 17 μg m -3, respectively. Activity patterns of the study population indicated a generally sedentary population spending a mean of 96% of each day indoors. Future studies would benefit from the use of a consistent sampling methodology across a larger number of PM measurement sites relevant to the elderly subjects, as well as a larger personal PM exposure study population to more successfully collect data needed in matched epidemiological-exposure studies.

  17. Continuous weeklong measurements of indoor particle levels in a Minnesota Tribal Casino Resort.

    Science.gov (United States)

    Zhou, Zheng; Bohac, David; Boyle, Raymond G

    2016-08-24

    Secondhand smoke (SHS) exposure for workers and patrons in hospitality venues is a persistent and significant public health concern. We designed this study to provide a comprehensive assessment of SHS exposure inside an Indian Tribal Casino in Minnesota. Real-time fine particulate matter (PM2.5) concentrations were measured at multiple locations for up to 7 days. The field monitoring provided information on the day of week and time of day variation of SHS exposure, as well as comparisons between smoking and non-smoking areas. Indoor PM2.5 level was nearly 13 times the concurrent outdoor PM2.5 level. Gaming floor hourly PM2.5 level was highest on Saturday night, averaged at 62.9 μg/m(3). Highest PM2.5 concentration was observed in smoking-permitted employee break room, reaching 600 μg/m(3). PM2.5 readings in non-smoking sections exhibited same temporal pattern as the readings in smoking sections. The results show that indoor concentration of PM2.5 is substantially higher than the outdoor level, posing health risks to casino workers and patrons. SHS can migrate into adjacent non-smoking areas very quickly. The casino's ventilation system did not fully eliminate SHS. A completely smoke-free casino would be the only way to fully protect non-smoking patrons and employees from the dangers of tobacco smoke.

  18. Resolving the influential parameters of thermal comfort perception amidst indoor-outdoor spatial transitions: Case study in a lecture room

    NARCIS (Netherlands)

    Derks, M.T.H.; Loomans, M.G.L.C.; Mishra, A.K.; Kort, H.S.M.

    2017-01-01

    Indoor to outdoor transitions have an undeniable impact on thermal perception of occupants and can impact their evaluation of a building. These aspects are often overlooked in thermal comfort standards. We address this gap using a mixed methods study, with students in undergraduate level classrooms

  19. Toxic effects of indoor and outdoor airborne particles relevant to carcinogenesis

    NARCIS (Netherlands)

    Heussen, G.A.H.

    1993-01-01

    The mutagenicity of indoor and outdoor airborne particulate matter (APM) has been demonstrated by previous in vitro studies (Alink et al., 1983; Van Houdt et al., 1984, 1986, 1987). The aim of the present thesis was to contribute to a better understanding of the mode of action of AIM in the

  20. The Los Angeles TEAM Study: personal exposures, indoor-outdoor air concentrations, and breath concentrations of 25 volatile organic compounds.

    Science.gov (United States)

    Wallace, L; Nelson, W; Ziegenfus, R; Pellizzari, E; Michael, L; Whitmore, R; Zelon, H; Hartwell, T; Perritt, R; Westerdahl, D

    1991-04-01

    The U.S. Environmental Protection Agency and the California Air Resources Board studied the exposures of 51 residents of Los Angeles, California, to 25 volatile organic chemicals (VOCs) in air and drinking water in 1987. A major goal of the study was to measure personal, indoor, and outdoor air concentrations, and breath concentrations of VOCs in persons living in households that had previously been measured in 1984. Other goals were to confirm the marked day-night and seasonal differences observed in 1984; to determine room-to-room variability within homes; to determine source emission rates by measuring air exchange rates in each home; and to extend the coverage of chemicals by employing additional sampling and analysis methods. A total of 51 homes were visited in February of 1987, and 43 of these were revisited in July of 1987. The results confirmed previous TEAM Study findings of higher personal and indoor air concentrations than outdoor concentrations of all prevalent chemicals (except carbon tetrachloride); higher personal, indoor, and outdoor air concentrations in winter than in summer; and (in winter only) higher outdoor concentrations at night than in the daytime. New findings included the following: (1) room-to-room variability of 12-hour average concentrations was very small, indicating that a single monitor may be adequate for estimating indoor concentrations over this time span; (2) "whole-house" source emission rates were relatively constant during both seasons, with higher rates for odorous chemicals such as p-dichlorobenzene and limonene (often used in room air fresheners) than for other classes of chemicals; (3) breath concentrations measured during morning and evening were similar for most participants, suggesting the suitability of breath measurements for estimating exposure in the home; (4) limited data obtained on two additional chemicals-toluene and methylene chloride-indicated that both were prevalent at fairly high concentrations and that

  1. Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong

    International Nuclear Information System (INIS)

    Guo, H.; Lee, S.C.; Chan, L.Y.

    2004-01-01

    To characterize indoor air quality at the markets in Hong Kong, three non-air-conditioned and two air-conditioned markets were selected for this study. The indoor air pollutants measured included PM 10 (particulate matters with aerodynamic diameter less than 10 μm), total bacteria count (TBC), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO 2 ) and sulfur dioxide (SO 2 ). The indoor and outdoor concentrations of these target air pollutants at these markets were measured and compared. The effects of air conditioning, temperature/relative humidity variation and different stalls on the indoor air quality were also investigated. The results indicated that all of the average indoor concentrations of PM 10 , TBC, CO and NO 2 at the markets were below the Hong Kong Indoor Air Quality Objectives (HKIAQO) standards with a few exceptions for PM 10 and TBC. The elevated PM 10 concentrations at Hung Hom, Ngau Tau Kok and Wan Chai markets were probably due to the air filtration of outdoor airborne particulates emitted from vehicular exhaust, whereas high concentrations of airborne bacteria at Sai Ying Pun and Tin Shing markets were linked to the use of air conditioning. Correlation analysis demonstrated that indoor bacteria concentrations were correlated with temperature and relative humidity. The operation of air conditioning did not significantly reduce the levels of air pollutants at the markets. However, the higher indoor/outdoor ratios demonstrated that the operation of air conditioning had influence on the levels of bacteria at the markets. It was found that average PM 10 concentration at poultry stalls was higher than the HKIAQO standard of 180 μg/m 3 , and was over two times that measured at vegetable, fish and meat stalls. Furthermore, the concentration of airborne bacteria at the poultry stalls was as high as 1031 CFU/m 3 , which was above the HKIAQO standard of 1000 CFU/m 3 . The bacteria levels at other three stalls were all below the HKIAQO standard

  2. Indoor air quality of houses located in the urban environment of Agra, India.

    Science.gov (United States)

    Taneja, Ajay; Saini, Renuka; Masih, Amit

    2008-10-01

    Increased concern over the adverse health effects of air pollution has highlighted the need for air-pollution measurements, especially in urban areas, where many sources of air pollutants are normally monitored outdoors as part of obligations under the National Air Quality Strategies. Very little is known about air pollution indoors. In fact, the largest exposure to health-damaging indoor pollution probably occurs in the developing world, not in households, schools, and offices of developed countries where most research and control efforts have been focused to date. As a result much of the health impacts from air pollution worldwide seem to occur among the poorest and most vulnerable populations. The authors in their earlier studies have confirmed the importance of ambient air in determining the quality of air indoors. In this study an observation of air quality indoors and outdoors of domestic homes located in an urban environment from October 2004 to December 2005 in Agra, north central India, is performed. The purpose of this study was to characterize the indoor/outdoor (I/O) relationship of airborne pollutants and recognize their probable source in all three seasons, that is, winter, summer, and rainy season. Concentrations of SO(2), NO(2), CO(2), Cl(2), H(2)S, NH(3), RSPM, and PAH were monitored simultaneously and I/O ratios were calculated. In order to investigate the effect of seasonality on indoor and ambient air quality, winter to summer and winter to monsoon average ratios were calculated. It is apparent that there is a general pattern of increasing levels from monsoon to summer to winter, and similarly from outdoor to indoor air. Regressions analysis had been done to further investigate the influence of outdoor air-pollutant concentrations on indoor concentrations. The most probable categories of sources for these pollutants have been identified by using principal-component analysis. Indoor air pollution is a complex function of energy housing and

  3. Indoor radon levels in coastal Karnataka

    International Nuclear Information System (INIS)

    Narayana, Y.; Radhakrishna, A.P.; Somashekarappa, H.M.; Karunakara, N.; Balakrishna, K.M.; Siddappa, K.

    1995-01-01

    Indoor radon levels have been measured in selected dwellings of coastal Karnataka using LR-115 type II peelable films and it is found to vary from 28.4 to 45.6 Bq m -3 with a geometric mean value of 35.7 Bq m -3 . The annual effective dose equivalent to the population of the region due to inhalation of radon was estimated from the measured data on radon level and is found to be in the range 1.9 - 3.1 mSv y -1 with a mean value 2.4 mSv y -1 . The correlation between indoor radon level and radium content in the underlying soil were studied. No definite correlation was observed to exist between indoor radon level and radium content in soil. (author). 24 refs., 2 tabs

  4. Indoor/Outdoor Seamless Positioning Using Lighting Tags and GPS Cellular Phones for Personal Navigation

    Science.gov (United States)

    Namie, Hiromune; Morishita, Hisashi

    The authors focused on the development of an indoor positioning system which is easy to use, portable and available for everyone. This system is capable of providing the correct position anywhere indoors, including onboard ships, and was invented in order to evaluate the availability of GPS indoors. Although the performance of GPS is superior outdoors, there has been considerable research regarding indoor GPS involving sensitive GPS, pseudolites (GPS pseudo satellite), RFID (Radio Frequency IDentification) tags, and wireless LAN .However, the positioning rate and the precision are not high enough for general use, which is the reason why these technologies have not yet spread to personal navigation systems. In this regard, the authors attempted to implement an indoor positioning system using cellular phones with built-in GPS and infrared light data communication functionality, which are widely used in Japan. GPS is becoming increasingly popular, where GPGGS sentences of the NMEA outputted from the GPS receiver provide spatiotemporal information including latitude, longitude, altitude, and time or ECEF xyz coordinates. As GPS applications grow rapidly, spatiotemporal data becomes key to the ubiquitous outdoor and indoor seamless positioning services at least for the entire area of Japan, as well as to becoming familiar with satellite positioning systems (e.g. GPS). Furthermore, the authors are also working on the idea of using PDAs (Personal Digital Assistants), as cellular phones with built-in GPS and PDA functionality are also becoming increasingly popular.

  5. Degradation of indoor limonene by outdoor ozone: A cascade of secondary organic aerosols.

    Science.gov (United States)

    Rösch, Carolin; Wissenbach, Dirk K; Franck, Ulrich; Wendisch, Manfred; Schlink, Uwe

    2017-07-01

    In indoor air, terpene-ozone reactions can form secondary organic aerosols (SOA) in a transient process. 'Real world' measurements conducted in a furnished room without air conditioning were modelled involving the indoor background of airborne particulate matter, outdoor ozone infiltrated by natural ventilation, repeated transient limonene evaporations, and different subsequent ventilation regimes. For the given setup, we disentangled the development of nucleated, coagulated, and condensed SOA fractions in the indoor air and calculated the time dependence of the aerosol mass fraction (AMF) by means of a process model. The AMF varied significantly between 0.3 and 5.0 and was influenced by the ozone limonene ratio and the background particles which existed prior to SOA formation. Both influencing factors determine whether nucleation or adsorption processes are preferred; condensation is strongly intensified by particulate background. The results provide evidence that SOA levels in natural indoor environments can surpass those known from chamber measurements. An indicator for the SOA forming potential of limonene was found to be limona ketone. Multiplying its concentration (in μg/m 3 ) by 450(±100) provides an estimate of the concentration of the reacted limonene. This can be used to detect a high particle formation potential due to limonene pollution, e.g. in epidemiological studies considering adverse health effects of indoor air pollutants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Indoor aldehydes: measurement of contamination levels and identification of their determinants in Paris dwellings

    International Nuclear Information System (INIS)

    Clarisse, B.; Laurent, A.M.; Seta, N.; Le Moullec, Y.; El Hasnaoui, A.; Momas, I.

    2003-01-01

    The recent increased prevalence of childhood asthma and atopy has brought into question the impact of outdoor pollutants and indoor air quality. The contributory role of aldehydes to this problem and the fact that they are mainly derived from the domestic environment make them of particular interest. This study therefore measures six different aldehyde levels in Paris dwellings from potentially different sources and identifies their indoor determinants. The study was carried out in the three principal rooms of 61 flats with no previous history of complaint for olfactory nuisance or specific symptoms, two-thirds of the flats having been recently refurbished. Aldehydes were sampled in these rooms using passive samplers, and a questionnaire on potential aldehyde sources was filled out at the same time. A multiple linear regression model was used to investigate indoor aldehyde determinants. Our study revealed that propionaldehyde and benzaldehyde were of minor importance compared to formaldehyde, acetaldehyde, pentanal, and hexanal. We found that levels of these last four compounds depended on the age of wall or floor coverings (renovations less than 1 year old), smoking, and ambient parameters (carbon dioxide levels, temperature). These results could help in the assessment of indoor aldehyde emissions

  7. Indoor and outdoor atmospheric fungal spores in the São Paulo metropolitan area (Brazil): species and numeric concentrations

    Science.gov (United States)

    Gonçalves, Fábio Luiz Teixeira; Bauer, Heidi; Cardoso, Maria Regina Alves; Pukinskas, Sandra; Matos, Dulcilena; Melhem, Márcia; Puxbaum, Hans

    2010-07-01

    The aim of this study was to estimate the indoor and outdoor concentrations of fungal spores in the Metropolitan Area of Sao Paulo (MASP), collected at different sites in winter/spring and summer seasons. The techniques adopted included cultivation (samples collected with impactors) and microscopic enumeration (samples collected with impingers). The overall results showed total concentrations of fungal spores as high as 36,000 per cubic meter, with a large proportion of non culturable spores (around 91% of the total). Penicillium sp. and Aspergillus sp. were the dominant species both indoors and outdoors, in all seasons tested, occurring in more than 30% of homes at very high concentrations of culturable airborne fungi [colony forming units(CFU) m-3]. There was no significant difference between indoor and outdoor concentrations. The total fungal spore concentration found in winter was 19% higher than that in summer. Heat and humidity were the main factors affecting fungal growth; however, a non-linear response to these factors was found. Thus, temperatures below 16°C and above 25°C caused a reduction in the concentration (CFU m-3) of airborne fungi, which fits with MASP climatalogy. The same pattern was observed for humidity, although not as clearly as with temperature given the usual high relative humidity (above 70%) in the study area. These results are relevant for public health interventions that aim to reduce respiratory morbidity among susceptible populations.

  8. Contrasts in spatial and temporal variability of oxidative capacity and elemental composition in moxibustion, indoor and outdoor environments in Beijing

    International Nuclear Information System (INIS)

    Huang, Jian; Lim, Min Yee; Hwang, Chaxi; Zhao, Baixiao; Shao, Longyi

    2015-01-01

    Moxibustion is a traditional Chinese medicine therapy that burns moxa floss which produces a substantial amount of PM 10 into the environment, thus spawning safety concerns about health impacts of the smoke. We compared the oxidative capacity and elemental composition of moxibustion-derived and ambient PM 10 in summer and winter to provide a source-, spatial- and temporal-comparison of PM 10 biological responses. The PM 10 oxidative capacity was 2.04 and 1.45 fold lower, and dose-dependent slope gradient was 2.36 and 1.76 fold lower in moxibustion environment than indoor or outdoor. Oxidative damage was highly correlated with iron, cesium, aluminum and cobalt in indoor, but moxibustion environment displayed low associations. The total elemental concentration was also lower in moxibustion environment than indoor (2.28 fold) or outdoor (2.79 fold). The source-to-dose modeling and slope gradient analysis in this study can be used as a model for future source-, spatial- and temporal-related moxibustion safety evaluation studies. - Highlights: • Source-, spatial- and temporal-comparisons of PM 10 of moxa smoke and ambient air. • Moxibustion environment had the lowest oxidative capacity temporally and spatially. • Total elemental concentration was also lowest in moxibustion environment. • Low correlations between metals and oxidative damage in moxibustion environment. • Moxibustion-derived PM 10 may not be as injurious to human health as thought. - Moxibustion-derived PM 10 had the lowest oxidative capacity and total elemental concentration when compared with indoor and outdoor environments

  9. Robustness of Visual Place Cells in Dynamic Indoor and Outdoor Environment

    Directory of Open Access Journals (Sweden)

    C. Giovannangeli

    2006-06-01

    Full Text Available In this paper, a model of visual place cells (PCs based on precise neurobiological data is presented. The robustness of the model in real indoor and outdoor environments is tested. Results show that the interplay between neurobiological modelling and robotic experiments can promote the understanding of the neural structures and the achievement of robust robot navigation algorithms. Short Term Memory (STM, soft competition and sparse coding are important for both landmark identification and computation of PC activities. The extension of the paradigm to outdoor environments has confirmed the robustness of the vision-based model and pointed to improvements in order to further foster its performance.

  10. Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong

    Science.gov (United States)

    Lee, Shun-Cheng; Guo, Hai; Li, Wai-Ming; Chan, Lo-Yin

    Indoor air quality in selected indoor environments in Hong Kong such as homes, offices, schools, shopping malls and restaurants were investigated. Average CO 2 levels and total bacteria counts in air-conditioned classrooms, shopping malls and restaurants were comparatively higher than those measured in occupied offices and homes. Elevated CO 2 levels exceeding 1000 ppm and total bacteria counts resulted from high occupancy combined with inadequate ventilation. Average PM 10 levels were usually higher indoors than outdoors in homes, shopping malls and restaurants. The highest indoor PM 10 levels were observed at investigated restaurants due to the presence of cigarette smoking and extensive use of gas stoves for cooking. The restaurants and shopping malls investigated had higher formaldehyde levels than other indoor environments when building material, smoking and internal renovation work were present. Volatile organic compounds (VOCs) in both indoor and outdoor environments mainly resulted from vehicle exhaust emissions. It was observed that interior decoration work and the use of industrial solvents in an indoor environment could significantly increase the indoor levels of VOCs.

  11. Continuous weeklong measurements of indoor particle levels in a Minnesota Tribal Casino Resort

    Directory of Open Access Journals (Sweden)

    Zheng Zhou

    2016-08-01

    Full Text Available Abstract Background Secondhand smoke (SHS exposure for workers and patrons in hospitality venues is a persistent and significant public health concern. We designed this study to provide a comprehensive assessment of SHS exposure inside an Indian Tribal Casino in Minnesota. Methods Real-time fine particulate matter (PM2.5 concentrations were measured at multiple locations for up to 7 days. The field monitoring provided information on the day of week and time of day variation of SHS exposure, as well as comparisons between smoking and non-smoking areas. Results Indoor PM2.5 level was nearly 13 times the concurrent outdoor PM2.5 level. Gaming floor hourly PM2.5 level was highest on Saturday night, averaged at 62.9 μg/m3. Highest PM2.5 concentration was observed in smoking-permitted employee break room, reaching 600 μg/m3. PM2.5 readings in non-smoking sections exhibited same temporal pattern as the readings in smoking sections. Conclusions The results show that indoor concentration of PM2.5 is substantially higher than the outdoor level, posing health risks to casino workers and patrons. SHS can migrate into adjacent non-smoking areas very quickly. The casino’s ventilation system did not fully eliminate SHS. A completely smoke-free casino would be the only way to fully protect non-smoking patrons and employees from the dangers of tobacco smoke.

  12. [Preventive effects of sound insulation windows on the indoor noise levels in a street residential building in Beijing].

    Science.gov (United States)

    Guo, Bin; Huang, Jing; Guo, Xin-biao

    2015-06-18

    To evaluate the preventive effects of sound insulation windows on traffic noise. Indoor noise levels of the residential rooms (on both the North 4th ring road side and the campus side) with closed sound insulation windows were measured using the sound level meter, and comparisons with the simultaneously measured outdoor noise levels were made. In addition, differences of indoor noise levels between rooms with closed sound insulation windows and open sound insulation windows were also compared. The average outdoor noise levels of the North 4th ring road was higher than 70 dB(A), which exceeded the limitation stated in the "Environmental Quality Standard for Noise" (GB 3096-2008) in our country. However, with the sound insulation windows closed, the indoor noise levels reduced significantly to the level under 35 dB(A) (Pwindows had significant influence on the indoor noise levels (Pwindow, when the sound insulation windows were closed, the indoor noise levels reduced 18.8 dB(A) and 8.3 dB(A) in residential rooms facing North 4th ring road side and campus side, respectively. The results indicated that installation of insulation windows had significant noise reduction effects on street residential buildings especially on the rooms facing major traffic roads. Installation of the sound insulation windows has significant preventive effects on indoor noise in the street residential building.

  13. Enviromental gamma rate in outdoor and indoor of Kermanshah provience in different seasons, (2010-11

    Directory of Open Access Journals (Sweden)

    Khosro Chopani

    2014-08-01

    Full Text Available Background: Background radiation exists naturally in the environment and affects all living organisms. Assessment of these radiations is important because they cause somatic & genetic damages. This survey was carried out to determine the environmental gamma rate was measured in different seasons in Kermanshah towns, and the effective dose for the residents of these regions was calculated. Methods: gamma dose rate was determined by Geiger Muller detector (RADOS CO, RDS-120.To this end, six and seven stations were selected in outdoor and indoor areas, respectively. In other towns‚ however, the measurements were performed at one station in outdoor center of each town. Results: The mean values of indoor and outdoor gamma dose rates in Kermanshah were 99.96 and 118.6 nSv/h, respectively and the mean values of environmental gamma in outdoor areas of Islamabad-e-Gharb‚ Songhor‚ Sahneh‚ Gilan-e-Gharb, Sarpol-e-Zahab‚ Ghasr-e-Shirin‚ Harsin‚ Paveh‚ Ravansar and Javanrood towns were 99.96 ‚ 120.5 ‚ 143 ‚ 115.7 ‚ 71.7 ‚ 76.2 ‚ 82 ‚ 108.5 ‚ 95.7‚ 95.7 and 106 nSv/h, respectively. Also, the highest and the lowest annual effective dose were reported for Songhor (0.88 mSv/y and Gilan-e-Gharb (0.44mSv/y, respectively. Conclusion: The outdoor annual effective doses for the residents of Kermanshah‚ Islamabad-e-Gharb‚ Sahneh‚ Gilan-e-Gharb‚ Sarpol-e-Zahab‚ Ghasr-e-Shirin‚ Harsin‚ Paveh‚ Ravansar and Javanrood were lower than the global value (0.76 mSv/y except for Songhor with 16% higher dose.

  14. Distribution and congener profiles of short-chain chlorinated paraffins in indoor/outdoor glass window surface films and their film-air partitioning in Beijing, China.

    Science.gov (United States)

    Gao, Wei; Wu, Jing; Wang, Yawei; Jiang, Guibin

    2016-02-01

    Short-chain chlorinated paraffins (SCCPs) are a group of n-alkanes with carbon chain length of 10-13. In this work, paired indoor/outdoor samples of organic films on window glass surfaces from urban buildings in Beijing, China, were collected to measure the concentrations and congener distributions of SCCPs. The total SCCP levels ranged from 337 ng/m(2) to 114 μg/m(2), with total organic carbon (TOC) normalized concentrations of 365 μg/m(2)-365 mg/m(2). Overall, the concentrations of SCCPs on the interior films were higher than the concentrations on the exterior films, suggesting an important indoor environmental exposure of SCCPs to the general public. A significant linear relationship was found between the SCCP concentrations and TOC, with a correlation coefficient of R = 0.34 (p film-air partitioning model suggests that the indoor gas-phase SCCPs are related to their corresponding window film levels. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Indoor organic and inorganic pollutants: In-situ formation and dry deposition in Southeastern Brazil

    Science.gov (United States)

    Allen, Andrew G.; Miguel, Antonio H.

    We have measured indoor and outdoor levels of particle- and gas-phase pollutants, collected in offices, restaurants and a hotel at six different sites in and around the cities of São Paulo and Campinas, Brazil, during summer 1993. Gas-phase species included acetic acid, formic acid, nitrous acid, hydrochloric acid, sulfur dioxide, nitric acid, oxalic acid, and pyruvic acid. Fine mode ( 3 μm dp) species measured included chloride, potassium, acetate, nitrate, magnesium, formate, sodium, pyruvate, nitrite, calcium, sulfate, oxalate, and ammonium. One sample (˜ 6 h) was simultaneously collected indoors and outdoors at each site during regular working hours. Indoor samplers were located ca. 1.5 m from the floor, and the outdoors immediately outside the window. Indoor/outdoor concentration ratios suggest that fine potassium chloride was produced indoors in appreciable amounts at both restaurants studied and, to a lesser extent, in the three offices as well. Indoor fine nitrate particles found in restaurants appear to have been produced by fuel combustion; a small fraction may have resulted from dry deposition of nitric acid onto existing fine particles. Indoor and outdoor concentrations of fine- and coarse-mode acetate suggest their production at all sites. The average concentration of gas-phase acetic acid was 42 μg m -3 indoors compared to 9.0 μg m -3 outdoors. In-situ formation of nitrous acid and acetic acid appears to have occurred at all indoor sites. High levels of formic and acetic acids were produced indoors at a pizzeria that used wood for cooking. Nitrous acid average concentrations for all sites were 8.4 μm m -3 indoors and 3.2 μm m -3 outdoors. Indoor/outdoor ratios at all sites suggest that dry deposition indoors may have occurred for hydrochloric acid, nitric acid and sulfur dioxide and that fine-mode sulfate infiltrate buildings from outside at most sites.

  16. A GPS Sensing Strategy for Accurate and Energy-Efficient Outdoor-to-Indoor Handover in Seamless Localization Systems

    Directory of Open Access Journals (Sweden)

    Yungeun Kim

    2012-01-01

    Full Text Available Indoor localization systems typically locate users on their own local coordinates, while outdoor localization systems use global coordinates. To achieve seamless localization from outdoors to indoors, a handover technique that accurately provides a starting position to the indoor localization system is needed. However, existing schemes assume that a starting position is known a priori or uses a naïve approach to consider the last location obtained from GPS as the handover point. In this paper, we propose an accurate handover scheme that monitors the signal-to-noise ratio (SNR of the effective GPS satellites that are selected according to their altitude. We also propose an energy-efficient handover mechanism that reduces the GPS sampling interval gradually. Accuracy and energy efficiency are experimentally validated with the GPS logs obtained in real life.

  17. Comparative indoor and outdoor degradation of organic photovoltaic cells via inter-laboratory collaboration

    NARCIS (Netherlands)

    Owens, C.; Ferguson, G.M.; Hermenau, M.; Voroshazi, E.; Galagan, Y.; Zimmermann, B.; Rosch, R.; Angamo, D.; Teran, G.; Uhrich, C.; Andriessen, R.; Hoppe, H.; Wurfel, U.; Lira-Cantu, M.; Krebs, F.; Tanenbaum, D.

    2015-01-01

    We report on the degradation of organic photovoltaic (OPV) cells in both indoor and outdoor environments. Eight different research groups contributed state of the art OPV cells to be studied at Pomona College. Power conversion efficiency, fill factor, and IV curves were collected at regular

  18. Indoor air quality in restaurant kitchens in the south Tehran (2006

    Directory of Open Access Journals (Sweden)

    F. Naseri

    2010-07-01

    Full Text Available Background and aims   Generally nitrogen dioxide (NO 2 and carbon monoxide (CO are emitted Toxic gases like carbon monoxide (CO., carbon dioxide (CO 2 , nitrogen oxides (NOx will remain in the kitchen when cooking with a gas stove. The purpose of the present study was to measure carbon monoxide (CO and nitrogen dioxide (NO 2 levels during the operation of cooking  in restaurant kitchens that use gas or natural gas, which are widely used in Tehran.     Methods   One hundred thirty one restaurants were chosen randomly from a list of 276 restaurants in five region different geographic categories, of the metropolitan Tehran, area, in summer 2006. Simultaneous indoor and outdoor air sampling occurred at each sampling site.   Carbon monoxide (CO and nitrogen dioxide (NO2 concentrations were measured by a real-time analyzer portable computer monitors.     Results   The results of this study showed that %83 and %68 kitchens had local exhaust ventilation and fan system, respectively. The results of this study showed that the mean concentrations of CO and NO 2 with gas stoves for food cooking in restaurant kitchens were below the standard which was established as TLV-TWA=25 and 3 ppm, respectively by ACGIH. The I/O  ratios of CO and NO 2 , were larger than 1 when there were indoor sources.     Conclusion  In this study, the mean levels of CO and NO 2 indoor were upper than the CO and  NO 2 outdoor the restaurants. Generally, improved methods of cooking besides appropriate  ventilation of all indoor combustion appliances, including gas stoves, should be adopted in  industrial kitchens

  19. Microbial Air Contamination in Indoor and Outdoor Environment of Pig Farms

    Directory of Open Access Journals (Sweden)

    Silvana Popescu

    2014-05-01

    Full Text Available Ensuring a good air quality in pig farms is important for the health of animals and human workers. The aim of this study was the assessment of the microbiological quality of the air inside the pig houses and outside of these. The study was accomplished in two pig-fattening farms in Cluj County. The microbiological air quality was assessed in the cold and warm season, by determination of the total counts of mesophilic bacteria, staphylococci, streptococci, gram-negative bacteria and fungi. The bacterial and fungal counts varied in the air of the investigated farms. In relation to the season the mean counts of bacteria and fungi were significantly higher (P 0.05 were found between the values of the parameters determined from the indoor air and those obtained outside, from a distance of 5 m from the pig houses. The numbers of the bacteria and fungi in the outdoor air lowered as the distance from the farms increased, the differences being significant at 25 and 50 m (P < 0.05. The results of the study show a high bacterial contamination of the indoor and outdoor air of the pig farms.

  20. Pollution sources for indoor PM2.5 at the platform in subway station using a positive matrix factorization and an instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jong Myoung; Moon, Jong Hwa; Chung, Yong Sam [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Jin Hong [Chungnam National University, Daejeon (Korea, Republic of)

    2010-05-15

    Airborne particulate matters, especially the PM2.5 (aerodynamic equivalent diameter, AED, less than 2.5 )m) fraction has been important. This is because of their potential for deposition on to the human respiratory system being accompanied by many harmful trace metals (such as As, Cd, Cr, Cu, Mn, Pb, Se, and Zn). As most people spend more than 80% of their time indoors, indoor air quality (IAQ) can exert a considerable impact on the inhalation condition of toxic substances. Therefore, assessment of the absolute concentration levels and elemental composition of PM in an indoor environment such as subway station can be used as a practical barometer of IAQ. The contaminants originated from the indoor pollution sources as well as various outdoor sources are easily accumulated in indoor environment dissimilar to the outdoor. Especially, since the natural ventilation is nearly impossible in the subway station, its pollution status can be worsened under the circumstance that contaminants are constantly originated and circulated inside of station by the repetitive action of subway trains. In this study, a total of 60 PM2.5 samples were collected for 4 seasonal campaigns in 2009 with a low-volume air sampler at one subway station in Daejeon, Korea. We undertook the measurements of up to 25 elements in PM2.5 using an instrumental neutron activation analysis (INAA) and X-ray fluorescence (XRF). And inorganic ion species (SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, NH{sub 4}{sup +}) also were determined by ion chromatography (IC). Next, sources at indoor/outdoor environment were identified and the contributions of each source were quantified by positive matrix factorization (PMF).

  1. Pollution sources for indoor PM2.5 at the platform in subway station using a positive matrix factorization and an instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lim, Jong Myoung; Moon, Jong Hwa; Chung, Yong Sam; Lee, Jin Hong

    2010-01-01

    Airborne particulate matters, especially the PM2.5 (aerodynamic equivalent diameter, AED, less than 2.5 )m) fraction has been important. This is because of their potential for deposition on to the human respiratory system being accompanied by many harmful trace metals (such as As, Cd, Cr, Cu, Mn, Pb, Se, and Zn). As most people spend more than 80% of their time indoors, indoor air quality (IAQ) can exert a considerable impact on the inhalation condition of toxic substances. Therefore, assessment of the absolute concentration levels and elemental composition of PM in an indoor environment such as subway station can be used as a practical barometer of IAQ. The contaminants originated from the indoor pollution sources as well as various outdoor sources are easily accumulated in indoor environment dissimilar to the outdoor. Especially, since the natural ventilation is nearly impossible in the subway station, its pollution status can be worsened under the circumstance that contaminants are constantly originated and circulated inside of station by the repetitive action of subway trains. In this study, a total of 60 PM2.5 samples were collected for 4 seasonal campaigns in 2009 with a low-volume air sampler at one subway station in Daejeon, Korea. We undertook the measurements of up to 25 elements in PM2.5 using an instrumental neutron activation analysis (INAA) and X-ray fluorescence (XRF). And inorganic ion species (SO 4 2- , NO 3 - , NH 4 + ) also were determined by ion chromatography (IC). Next, sources at indoor/outdoor environment were identified and the contributions of each source were quantified by positive matrix factorization (PMF).

  2. Correspondence between Children's Indoor and Outdoor Play in Japanese Preschool Daily Life

    Science.gov (United States)

    Hirose, Toshiya; Koda, Naoko; Minami, Tetsuhiro

    2012-01-01

    This study examined the correspondence between children's indoor and outdoor play in a preschool environment to investigate whether the children maintained a tendency to engage in a particular type of play irrespective of the environment, or whether they changed the type of play according to the environment. Play behaviours of 18 three-year-old…

  3. Comparative Indoor and Outdoor Degradation of Organic Photovoltaic Cells via Inter-laboratory Collaboration

    DEFF Research Database (Denmark)

    Owens, Charles; Ferguson, Gretta Mae; Hermenau, Martin

    2015-01-01

    We report on the degradation of organic photovoltaic (OPV) cells in both indoor and outdoor environments. Eight different research groups contributed state of the art OPV cells to be studied at Pomona College. Power conversion efficiency, fill factor, and IV curves were collected at regular inter...

  4. Comparative indoor and outdoor degradation of organic photovoltaic cells via inter-laboratory collaboration

    NARCIS (Netherlands)

    Owens, C.; Ferguson, G.M.; Hermenau, M.; Voroshazi, E.; Galagan, Y.; Zimmermann, B.; Rösch, R.; Angmo, D.; Teran-Escobar, G.; Uhrich, C.; Andriessen, R.; Hoppe, H.; Würfel, U.; Lira-Cantu, M.; Krebs, F.C.; Tanenbaum, D.M.

    2015-01-01

    We report on the degradation of organic photovoltaic (OPV) cells in both indoor and outdoor environments. Eight different research groups contributed state of the art OPV cells to be studied at Pomona College. Power conversion efficiency and fill factor were determined from IV curves collected at

  5. Novel method for estimation of the indoor-to-outdoor airborne radioactivity ratio following the Fukushima Daiichi Nuclear Power Plant accident

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Yanliang, E-mail: hytyl@163.com [College of Physics and Electronic Engineering, Hengyang Normal University, Hengyang, Hunan Province (China); Ishikawa, Tetsuo [Fukushima Medical University, 1 Hikariga-oka, Fukushima (Japan); Janik, Miroslaw [Regulatory Science Research Program, National Institute of Radiological Sciences, Chiba (Japan); Tokonami, Shinji [Department of Radiation Physics, Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Aomori (Japan); Hosoda, Masahiro [Hirosaki University Graduate School of Health Science, Hirosaki, Aomori (Japan); Sorimachi, Atsuyuki [Fukushima Medical University, 1 Hikariga-oka, Fukushima (Japan); Kearfott, Kimberlee [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI (United States)

    2015-12-01

    The accident at the Fukushima Daiichi Nuclear Power Plant (FDNPP) in Japan resulted in significant releases of fission products. While substantial data exist concerning outdoor air radioactivity following the accident, the resulting indoor radioactivity remains pure speculation without a proper method for estimating the ratio of the indoor to outdoor airborne radioactivity, termed the airborne sheltering factor (ASF). Lacking a meaningful value of the ASF, it is difficult to assess the inhalation doses to residents and evacuees even when outdoor radionuclide concentrations are available. A simple model was developed and the key parameters needed to estimate the ASF were obtained through data fitting of selected indoor and outdoor airborne radioactivity measurement data obtained following the accident at a single location. Using the new model with values of the air exchange rate, interior air volume, and the inner surface area of the dwellings, the ASF can be estimated for a variety of dwelling types. Assessment of the inhalation dose to individuals readily follows from the value of the ASF, the person's indoor occupancy factor, and the measured outdoor radioactivity concentration. - Highlights: • Actual ASF of the dwells is very important to estimate the inhalation dose. • A simple model is developed to describe ASF. • The key parameter of ASF is obtained from the measurement of NIRS. • The ASF of any dwellings can be obtained by our model and relatively parameters.

  6. Depressive-like behavior, its sensitization, social buffering, and altered cytokine responses in rhesus macaques moved from outdoor social groups to indoor housing.

    Science.gov (United States)

    Hennessy, Michael B; Chun, Katie; Capitanio, John P

    2017-02-01

    Psychosocial stressors appear to promote the onset of depressive illness through activation and sensitization of inflammatory mechanisms. Here, adult male rhesus monkeys brought from large outdoor social groups to indoor housing for 8 days reliably exhibited a hunched, depressive-like posture. When rehoused indoors a second 8 days about 2 weeks later, monkeys housed alone, but not those with an affiliative partner, showed sensitization of the depressive-like hunched posture. Housing indoors also affected circulating pro-inflammatory cytokines: IL-1β showed increased responsiveness to immune challenge, and IL-1β and TNF-α showed reduced suppression by dexamethasone. Sensitivity of the anti-inflammatory cytokine IL-10 to immune challenge exhibited a relative increase from the first to the second round of indoor housing in animals housed in pairs, and a relative decrease in animals housed alone. Cytokine levels during indoor housing were positively correlated with duration of depressive-like behavior. Plasma cortisol levels increased but did not differentiate housing conditions or rounds. Results demonstrate a rapid induction and sensitization of depressive-like behavior to indoor individual housing, social buffering of sensitization, and associated inflammatory responses. This paradigm may provide a practical nonhuman primate model for examining inflammatory-mediated consequences of psychosocial stressors on depression and possible social buffering of these effects.

  7. Magnetic field action on outdoor and indoor cultures of Spirulina: Evaluation of growth, medium consumption and protein profile.

    Science.gov (United States)

    Deamici, Kricelle Mosquera; Santos, Lucielen Oliveira; Costa, Jorge Alberto Vieira

    2018-02-01

    This study aimed at evaluating whether a magnetic field (MF) affects the growth of Spirulina sp. when applied to it at different exposure times in indoor and outdoor culture systems. The effects of MF on chlorophyll content, medium consumption and protein profile were also investigated. In raceway tanks, a 25 mT MF was applied for 24 h or for 1 h d -1 . MF for 24 h to outdoor assays increased biomass concentration and chlorophyll-a content besides altering the protein profile. Outdoor Spirulina growth was higher (∼3.65 g L -1 ) than the growth found in indoor assays (∼1.80 g L -1 ), while nitrogen and phosphorus consumption was not enhanced by the application of MF. This is the first study that investigated the influence of MF on outdoor microalga assays, and the results showed that MF affected the metabolism of Spirulina cultured in raceways, especially when it was grown outdoors in uncontrolled environmental conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Effects of indoor and outdoor cultivation conditions on 137 Cs concentrations in cultivated mushrooms produced after the Fukushima Daiichi Nuclear Power Plant accident.

    Science.gov (United States)

    Tagami, Keiko; Uchida, Shigeo; Ishii, Nobuyoshi

    2017-01-01

    Radiocesium ( 134 Cs and 137 Cs) in mushrooms has been a matter of public concern after the accident at Fukushima Daiichi Nuclear Power Plant. To minimize the internal dose by ingestion of cultivated mushrooms, the Japanese government set a guideline level with respect to the radiocesium concentration in bed-logs and mushroom beds; however, the effects of indoor and outdoor cultivation methods on radiocesium concentrations in cultivated mushrooms were not clear. The effects of indoor and outdoor cultivation on the radiocesium concentrations in mushroom were examined using published food monitoring data. 137 Cs concentration data in Lentinula edodes from the Aizu area in Fukushima Prefecture and seven prefectures outside Fukushima were used for the analysis. No statistically significant 137 Cs concentration differences were found between these two cultivation methods. Using detected 137 Cs data in shiitake, the geometric means from each prefecture were less than one-quarter of the standard limit (100 Bq kg -1 ) for total radiocesium under both cultivation conditions. It was suspected that re-suspended radiocesium might have been taken up by mushrooms or that radiocesium might have been absorbed into the mushrooms from the soil in the outdoor cultures. However, neither effect was significant for cultivated mushrooms in the areas examined. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  9. Heat stress in urban areas. Indoor and outdoor temperatures in different urban structure types and subjectively reported well-being during a heat wave in the city of Leipzig

    Energy Technology Data Exchange (ETDEWEB)

    Franck, Ulrich; Roeder, Stefan; Schlink, Uwe [Helmholtz Centre for Environmental Research - UFZ, Leipzig (Germany). Core Facility Studies; Krueger, Michael [Leipzig Univ. (Germany). Inst. of Geography; Schwarz, Nina [Helmholtz Centre for Environmental Research - UFZ, Leipzig (Germany). Dept. of Computational Landscape Ecology; Grossmann, Katrin [Helmholtz Centre for Environmental Research - UFZ, Leipzig (Germany). Dept. of Urban and Environmental Sociology

    2013-04-15

    Climate projections for Leipzig suggest elevated minimum and maximum temperatures as well as more frequent days with high temperatures. Hence, climate change is threatening human well-being and health. People spend the majority of their time indoors. Therefore, indoor temperatures (especially during the night) are of special importance with respect to well-being and health. Indoor air temperature depends on outdoor air temperatures, but is for example modified by type of urban structure, housing area, and may be also influenced by differences in the behavior of the inhabitants. Especially in cities, outdoor air temperatures depend on urban structure e.g. housing density, building arrangement, unpaved areas, types of urban structures, urban green, and other factors. Hence, the questions arise how types of urban structures are related to inner-urban temperature differences and how outdoor air temperatures influence indoor temperatures in dependence on urban housing conditions. This work is a part of a pilot study conducted during the summer 2010 which gathered data from remote sensing, mobile measurements, stationary measurements of air temperatures and relative humidity in areas with different housing structures, and of indoor as well as outdoor temperatures in occupied apartments. Household-survey data reported the subjective perception of heat stress. The study resulted in rather complex relationships between type of housing areas, indoor and outdoor temperatures, morning and evening temperatures, indoor and outdoor temperatures as well as subjective heat perception. Green spaces and types of residential areas are related to air temperatures. More green resulted in lower temperatures. Temperatures have a tendency to increase with increasing story number and are significantly higher in the top floor. An indoor heat island effect corresponding to the outdoor effect could be shown for the homes: Distance to city center is a predicting variable for both outdoor and

  10. Heat stress in urban areas: Indoor and outdoor temperatures in different urban structure types and subjectively reported well-being during a heat wave in the city of Leipzig

    Directory of Open Access Journals (Sweden)

    Ulrich Franck

    2013-04-01

    Full Text Available Climate projections for Leipzig suggest elevated minimum and maximum temperatures as well as more frequent days with high temperatures. Hence, climate change is threatening human well-being and health. People spend the majority of their time indoors. Therefore, indoor temperatures (especially during the night are of special importance with respect to well-being and health. Indoor air temperature depends on outdoor air temperatures, but is for example modified by type of urban structure, housing area, and may be also influenced by differences in the behavior of the inhabitants. Especially in cities, outdoor air temperatures depend on urban structure e.g. housing density, building arrangement, unpaved areas, types of urban structures, urban green, and other factors. Hence, the questions arise how types of urban structures are related to inner-urban temperature differences and how outdoor air temperatures influence indoor temperatures in dependence on urban housing conditions. This work is a part of a pilot study conducted during the summer 2010 which gathered data from remote sensing, mobile measurements, stationary measurements of air temperatures and relative humidity in areas with different housing structures, and of indoor as well as outdoor temperatures in occupied apartments. Household-survey data reported the subjective perception of heat stress. The study resulted in rather complex relationships between type of housing areas, indoor and outdoor temperatures, morning and evening temperatures, indoor and outdoor temperatures as well as subjective heat perception. Green spaces and types of residential areas are related to air temperatures. More green resulted in lower temperatures. Temperatures have a tendency to increase with increasing story number and are significantly higher in the top floor. An indoor heat island effect corresponding to the outdoor effect could be shown for the homes: Distance to city center is a predicting variable for

  11. Seasonal and Spatial Variations of Indoor Pollen in a Hospital

    Directory of Open Access Journals (Sweden)

    Santiago Fernández-Rodríguez

    2009-12-01

    Full Text Available The airborne indoor pollen in a hospital of Badajoz (Spain was monitored over two years using a personal Burkard sampler. The air was sampled in four places indoors—one closed room and one open ward on each of the ground and the third floors—and one place outdoors at the entrance to the hospital. The results were compared with data from a continuous volumetric sampler. While 32 pollen types were identified, nearly 75% of the total counts were represented by just five of them. These were: Quercus, Cupressaceae, Poaceae, Olea, and Plantago. The average indoor concentration was 25.2 grains/m3, and the average indoor/outdoor ratio was 0.27. A strong seasonal pattern was found, with the highest levels in spring and winter, and the indoor concentrations were correlated with the outdoor one. Indoor air movement led to great homogeneity in the airborne pollen presence: the indoor results were not influenced by whether or not the room was isolated, the floor level, or the number of people in or transiting the site during sampling. The presence of ornamental vegetation in the area surrounding the building affected the indoor counts directly as sources of the pollen.

  12. Simultaneous sampling of indoor and outdoor airborne radioactivity after the Fukushima Daiichi nuclear power plant accident.

    Science.gov (United States)

    Ishikawa, Tetsuo; Sorimachi, Atsuyuki; Arae, Hideki; Sahoo, Sarata Kumar; Janik, Miroslaw; Hosoda, Masahiro; Tokonami, Shinji

    2014-02-18

    Several studies have estimated inhalation doses for the public because of the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident. Most of them were based on measurement of radioactivity in outdoor air and included the assumption that people stayed outdoors all day. Although this assumption gives a conservative estimate, it is not realistic. The "air decontamination factor" (ratio of indoor to outdoor air radionuclide concentrations) was estimated from simultaneous sampling of radioactivity in both inside and outside air of one building. The building was a workplace and located at the National Institute of Radiological Sciences (NIRS) in Chiba Prefecture, Japan. Aerosol-associated radioactive materials in air were collected onto filters, and the filters were analyzed by γ spectrometry at NIRS. The filter sampling was started on March 15, 2011 and was continued for more than 1 year. Several radionuclides, such as (131)I, (134)Cs, and (137)Cs were found by measuring the filters with a germanium detector. The air decontamination factor was around 0.64 for particulate (131)I and 0.58 for (137)Cs. These values could give implications for the ratio of indoor to outdoor radionuclide concentrations after the FDNPP accident for a similar type of building.

  13. Indoor multipath mitigation

    DEFF Research Database (Denmark)

    Dragünas, Kostas; Borre, Kai

    2010-01-01

    There are many applications that require continuous positioning in combined outdoor urban and indoor environments. GNSS has been used for a long time in outdoor environments, while indoor positioning is still a challenging task. One of the major degradations that GNSS receivers experience indoors...

  14. Indoor air quality: a UK perspective

    International Nuclear Information System (INIS)

    Wadge, A.

    1995-01-01

    Outdoor air quality has generally improved in the UK over the last 2 decades but during this period changing conditions within the home have tended to reduce ventilation and increase the opportunity for accumulation of undesirable levels of indoor air pollutants. Information obtained from laboratory and epidemiological studies suggest that indoor air pollutants are an important cause of avoidable morbidity and mortality in the UK. This paper reviews the major indoor air pollutants of concern in the UK and considers some of the special issues relevant to indoor environment. (author) 3 figs., 37 refs

  15. Association of indoor air pollution with rhinitis symptoms, atopy and nitric oxide levels in exhaled air

    DEFF Research Database (Denmark)

    Hersoug, Lars-Georg; Husemoen, Lise Lotte N; Thomsen, Simon Francis

    2010-01-01

    Exposure to particulate matter (PM) outdoors can induce airway inflammation and exacerbation of asthma in adults. However, there is limited knowledge about the effects of exposure to indoor PM. The aim of this study was to investigate the association of exposure to indoor sources of PM...... with rhinitis symptoms, atopy and nitric oxide in exhaled air (FeNO) as a measure of airway inflammation....

  16. The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Reda, Ibrahim; Robinson, Justin

    2016-06-02

    This study addresses the effect of calibration methodologies on calibration responsivities and the resulting impact on radiometric measurements. The calibration responsivities used in this study are provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides outdoor calibration responsivity of pyranometers and pyrheliometers at a 45 degree solar zenith angle and responsivity as a function of solar zenith angle determined by clear-sky comparisons to reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison of the test radiometer under calibration to a reference radiometer of the same type. These different methods of calibration demonstrated 1percent to 2 percent differences in solar irradiance measurement. Analyzing these values will ultimately enable a reduction in radiometric measurement uncertainties and assist in developing consensus on a standard for calibration.

  17. Commuters’ Personal Exposure to Ambient and Indoor Ozone in Athens, Greece

    Directory of Open Access Journals (Sweden)

    Krystallia K. Kalimeri

    2017-07-01

    Full Text Available This pilot study aimed to monitor the residential/office indoor, outdoor, and personal levels of ozone for people living, working, and commuting in Athens, Greece. Participants (16 persons of this study worked at the same place. Passive sampling analysis results did not indicate any limit exceedance (Directive 2008/50/EC: 120 µg/m3, World Health Organization (WHO Air Quality Guidelines 2005: 100 µg/m3. The highest “house-outdoor” concentration was noticed for participants living in the north suburbs of Athens, confirming the photochemical ozone formation at the northern parts of the basin during southwestern prevailing winds. The residential indoor to outdoor ratio (I/O was found to be significantly lower than unity, underlying the outdoor originality of the pollutant. The highest “office-indoor” concentration was observed in a ground-level building, characterized by the extensive use of photocopy machines and printers. Personal ozone levels were positively correlated only with indoor-office concentrations. A clear correlation of personal ozone levels to the time spent by the individuals during moving/staying outdoors was observed. On the other hand, no correlation was observed when focusing only on commuting time, due to the fact that transit time includes both on-foot and in-vehicle time periods, therefore activities associated with increased exposure levels, but also with pollutants removal by recirculating air filtering systems, respectively.

  18. An Analysis of Engagement in a Combination Indoor/Outdoor Augmented Reality Educational Game

    Science.gov (United States)

    Folkestad, James; O'Shea, Patrick

    2011-01-01

    This paper describes the results of a qualitative analysis of video captured during a dual indoor/outdoor Augmented Reality experience. Augmented Reality is the layering of virtual information on top of the physical world. This Augmented Reality experience asked students to interact with the San Diego Museum of Art and the Botanical Gardens in San…

  19. Peripheral and gastrointestinal immune systems of healthy cattle raised outdoors at pasture or indoors on a concentrate-based ration

    Directory of Open Access Journals (Sweden)

    Reilly Petrina

    2010-03-01

    Full Text Available Abstract Background Despite an increasing preference of consumers for beef produced from more extensive pasture-based production systems and potential human health benefits from the consumption of such beef, data regarding the health status of animals raised on pasture are limited. The objective of this study was to characterise specific aspects of the bovine peripheral and the gastrointestinal muscosal immune systems of cattle raised on an outdoor pasture system in comparison to animals raised on a conventional intensive indoor concentrate-based system. Results A number of in vitro functional tests of immune cells suggested subtle differences between the animals on the outdoor versus indoor production systems. There was a decrease in the number of neutrophils and monocytes engaged in phagocytosis in outdoor cattle (P P P P P P P Conclusion Despite distinctly contrasting production systems, only subtle differences were identified in the peripheral immune parameters measured between cattle raised at pasture in comparison to animals raised on a conventional intensive indoor concentrate-based production system.

  20. Soil seed banks and their germination responses to cadmium and salinity stresses in coastal wetlands affected by reclamation and urbanization based on indoor and outdoor experiments.

    Science.gov (United States)

    Bai, Junhong; Huang, Laibin; Gao, Zhaoqin; Lu, Qiongqiong; Wang, Junjing; Zhao, Qingqing

    2014-09-15

    Indoor and outdoor seedling emergence experiments were conducted to thoroughly investigate germination patterns as affected by reclamation and urbanization, the ecological characteristics of soil seed banks, and their relationships with environmental factors in both urbanized and reclaimed regions of the Pearl River Delta in coastal wetlands. The germination rate of the soil seed bank was higher in the indoor experiment compared with that in the outdoor experiment, whereas the number and destiny of the germinated seedlings were greater in the outdoor experiment. The species diversity and number, as well as the richness and evenness indices, were higher in the urbanized region compared with the reclaimed region. However, the dominance and Sørensen similarity indices were greater in the reclaimed region compared with those indices in the urbanized region. Higher salinity and Cadmium (Cd) levels could inhibit seed germination; however, their suitable ranges (i.e. [0-2,000 mg kg(-1)] for salinity and [0-4.0 mg kg(-1)] for available Cd) can activate seedling emergence, and more seedlings germinated under the intersectional levels at 0.34 mg kg(-1) available Cd and 778.6 mg kg(-1) salinity. Seawater intrusion caused by the sea level rise will possibly result in the salt-tolerant community in this area due to increasing salinity. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Impact of the 2011 Spanish smoking ban in hospitality venues: indoor secondhand smoke exposure and influence of outdoor smoking.

    Science.gov (United States)

    López, María J; Fernández, Esteve; Pérez-Rios, Mónica; Martínez-Sánchez, Jose M; Schiaffino, Anna; Galán, Iñaki; Moncada, Albert; Fu, Marcela; Montes, Agustín; Saltó, Esteve; Nebot, Manel

    2013-05-01

    The Spanish tobacco control law of 2006 was modified in January 2011, banning smoking in all hospitality venues. The objective of the study was to assess the impact of the 2011 Spanish smoking ban on secondhand smoke (SHS) exposure in hospitality venues, and to analyze the potential impact of outdoor smokers close to entrances on indoor SHS levels after the law came into force. Before-and-after evaluation study with repeated measures. The study was carried out in three regions of Spain (Catalonia, Galicia, and Madrid) and included a random sample of 178 hospitality venues. We measured vapor-phase nicotine and particulate matter 2.5 micrometers or less in diameter (PM2.5) as SHS markers at baseline (November-December 2010) and at follow-up (April-June 2011). We also recorded tobacco consumption variables such as the presence of butts, ashtrays, and smokers. In the posttest assessment, we also recorded the number of outdoor smokers close to the entrance. A total of 351 nicotine and 160 PM2.5 measurements were taken. Both nicotine and PM2.5 concentrations decreased by more than 90% (nicotine from 5.73 to 0.57 µg/m(3), PM2.5 from 233.38 to 18.82 µg/m(3)). After the law came into force, both nicotine and PM2.5 concentrations were significantly higher in venues with outdoor smokers close to the entrance than in those without outdoor smokers. All the observational tobacco consumption variables significantly decreased (p hospitality venues dramatically decreased after the 2011 Spanish smoking ban. SHS from outdoor smokers close to entrances seems to drift inside venues. Smoking control legislation should consider outdoor restrictions to ensure complete protection against SHS.

  2. Modelling of indoor exposure to nitrogen dioxide in the UK

    Science.gov (United States)

    Dimitroulopoulou, C.; Ashmore, M. R.; Byrne, M. A.; Kinnersley, R. P.

    A dynamic multi-compartment computer model has been developed to describe the physical processes determining indoor pollutant concentrations as a function of outdoor concentrations, indoor emission rates and building characteristics. The model has been parameterised for typical UK homes and workplaces and linked to a time-activity model to calculate exposures for a representative homemaker, schoolchild and office worker, with respect to NO 2. The estimates of population exposures, for selected urban and rural sites, are expressed in terms of annual means and frequency of hours in which air quality standards are exceeded. The annual mean exposures are estimated to fall within the range of 5-21 ppb for homes with no source, and 21-27 ppb for homes with gas cooking, varying across sites and population groups. The contribution of outdoor exposure to annual mean NO 2 exposure varied from 5 to 24%, that of indoor penetration of outdoor air from 17 to 86% and that of gas cooking from 0 to 78%. The frequency of exposure to 1 h mean concentrations above 150 ppb was very low, except for people cooking with gas.

  3. Effects of types of ventilation system on indoor particle concentrations in residential buildings.

    Science.gov (United States)

    Park, J S; Jee, N-Y; Jeong, J-W

    2014-12-01

    The objective of this study was to quantify the influence of ventilation systems on indoor particle concentrations in residential buildings. Fifteen occupied, single-family apartments were selected from three sites. The three sites have three different ventilation systems: unbalanced mechanical ventilation, balanced mechanical ventilation, and natural ventilation. Field measurements were conducted between April and June 2012, when outdoor air temperatures were comfortable. Number concentrations of particles, PM2.5 and CO2 , were continuously measured both outdoors and indoors. In the apartments with natural ventilation, I/O ratios of particle number concentrations ranged from 0.56 to 0.72 for submicron particles, and from 0.25 to 0.60 for particles larger than 1.0 μm. The daily average indoor particle concentration decreased to 50% below the outdoor level for submicron particles and 25% below the outdoor level for fine particles, when the apartments were mechanically ventilated. The two mechanical ventilation systems reduced the I/O ratios by 26% for submicron particles and 65% for fine particles compared with the natural ventilation. These results showed that mechanical ventilation can reduce exposure to outdoor particles in residential buildings. Results of this study confirm that mechanical ventilation with filtration can significantly reduce indoor particle levels compared with natural ventilation. The I/O ratios of particles substantially varied at the naturally ventilated apartments because of the influence of variable window opening conditions and unsteadiness of wind flow on the penetration of outdoor air particles. For better prediction of the exposure to outdoor particles in naturally ventilated residential buildings, it is important to understand the penetration of outdoor particles with variable window opening conditions. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Indoor air quality in the Greater Beirut area: a characterization and modeling assessment

    International Nuclear Information System (INIS)

    El-Fadel, Mutasem; El-Hougeiri, Nisrine; Oulabi, Mawiya

    2003-01-01

    This report presents the assessment of IAQ at various environments selected from different geographic categories from the Greater Beirut area (GBA) in Lebanon. For this purpose, background information about indoor air quality was reviewed, existing conditions were characterized, an air-sampling program was implemented and mathematical modeling was conducted. Twenty-eight indoor buildings were selected from various geographic categories representing different environments (commercial and residential...). Indoor and outdoor air samples were collected and analyzed using carbon monoxide (CO), particulate matter (TSP), nitrogen dioxide (NO 2 ) and total volatile organic compounds (TVOC) as indicators of indoor air pollution (IAP).Samples were further analyzed using the energy dispersive x-ray fluorescence technique (EDXRF) for the presence of major priority metals including iron (Fe), calcium (Ca), zinc (Zn), lead (Pb), manganese (Mn), copper (Cu) and bromine (Br). Indoor and outdoor measured levels were compared to the American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE) and health-based National Ambient Air Quality standards (NAAQS), respectively. For the priority metals, on the other hand, indoor measured values were compared to occupational standards recommended by the National Institute of Occupational Safety and Health (NIOSH) and Occupational Safety and Health Administration (OSHA)

  5. National patterns in environmental injustice and inequality: outdoor NO2 air pollution in the United States.

    Science.gov (United States)

    Clark, Lara P; Millet, Dylan B; Marshall, Julian D

    2014-01-01

    We describe spatial patterns in environmental injustice and inequality for residential outdoor nitrogen dioxide (NO2) concentrations in the contiguous United States. Our approach employs Census demographic data and a recently published high-resolution dataset of outdoor NO2 concentrations. Nationally, population-weighted mean NO2 concentrations are 4.6 ppb (38%, p2.5 hours/week of physical activity). Inequality for NO2 concentration is greater than inequality for income (Atkinson Index: 0.11 versus 0.08). Low-income nonwhite young children and elderly people are disproportionately exposed to residential outdoor NO2. Our findings establish a national context for previous work that has documented air pollution environmental injustice and inequality within individual US metropolitan areas and regions. Results given here can aid policy-makers in identifying locations with high environmental injustice and inequality. For example, states with both high injustice and high inequality (top quintile) for outdoor residential NO2 include New York, Michigan, and Wisconsin.

  6. National patterns in environmental injustice and inequality: outdoor NO2 air pollution in the United States.

    Directory of Open Access Journals (Sweden)

    Lara P Clark

    Full Text Available We describe spatial patterns in environmental injustice and inequality for residential outdoor nitrogen dioxide (NO2 concentrations in the contiguous United States. Our approach employs Census demographic data and a recently published high-resolution dataset of outdoor NO2 concentrations. Nationally, population-weighted mean NO2 concentrations are 4.6 ppb (38%, p2.5 hours/week of physical activity. Inequality for NO2 concentration is greater than inequality for income (Atkinson Index: 0.11 versus 0.08. Low-income nonwhite young children and elderly people are disproportionately exposed to residential outdoor NO2. Our findings establish a national context for previous work that has documented air pollution environmental injustice and inequality within individual US metropolitan areas and regions. Results given here can aid policy-makers in identifying locations with high environmental injustice and inequality. For example, states with both high injustice and high inequality (top quintile for outdoor residential NO2 include New York, Michigan, and Wisconsin.

  7. Indoor air quality in Portuguese schools: levels and sources of pollutants.

    Science.gov (United States)

    Madureira, J; Paciência, I; Pereira, C; Teixeira, J P; Fernandes, E de O

    2016-08-01

    Indoor air quality (IAQ) parameters in 73 primary classrooms in Porto were examined for the purpose of assessing levels of volatile organic compounds (VOCs), aldehydes, particulate matter, ventilation rates and bioaerosols within and between schools, and potential sources. Levels of VOCs, aldehydes, PM2.5 , PM10 , bacteria and fungi, carbon dioxide (CO2 ), carbon monoxide, temperature and relative humidity were measured indoors and outdoors and a walkthrough survey was performed concurrently. Ventilation rates were derived from CO2 and occupancy data. Concentrations of CO2 exceeding 1000 ppm were often encountered, indicating poor ventilation. Most VOCs had low concentrations (median of individual species <5 μg/m(3) ) and were below the respective WHO guidelines. Concentrations of particulate matter and culturable bacteria were frequently higher than guidelines/reference values. The variability of VOCs, aldehydes, bioaerosol concentrations, and CO2 levels between schools exceeded the variability within schools. These findings indicate that IAQ problems may persist in classrooms where pollutant sources exist and classrooms are poorly ventilated; source control strategies (related to building location, occupant behavior, maintenance/cleaning activities) are deemed to be the most reliable for the prevention of adverse health consequences in children in schools. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. First characterization of the endocrine-disrupting potential of indoor gaseous and particulate contamination: comparison with urban outdoor air (France).

    Science.gov (United States)

    Oziol, Lucie; Alliot, Fabrice; Botton, Jérémie; Bimbot, Maya; Huteau, Viviane; Levi, Yves; Chevreuil, Marc

    2017-01-01

    The composition of endocrine-disrupting compounds (EDCs) in the ambient air of indoor environments has already been described, but little is known about the inherent endocrine-disrupting potential of indoor air contamination. We therefore aimed to study the distribution of bioactive EDCs in the gaseous and particulate phases of indoor air using a cellular bioassay approach that integrates the interaction effects between chemicals. Organic air extracts, both gaseous and particulate, were taken from three indoor locations (office, apartment, and children's day care) in France and sampled in two different seasons in order to study their interference with the signaling of estrogen, androgen, and thyroid receptors. The experiments were also conducted on aerial extracts from an outdoor site (urban center). We found that gaseous and/or particulate extracts from all locations displayed estrogenicity, anti-androgenicity, and thyroidicity. Overall, indoor air extracts had a higher endocrine-disrupting potential compared to outdoor ones, especially during winter and in the day care. The biological activities were predominant for the gaseous extracts and tended to increase for the particulate extracts in cool conditions. In conclusion, our data confirmed the presence of bioactive EDCs in a gaseous state and highlighted their indoor origin and concentration, especially in the cold season.

  9. Soil seed banks and their germination responses to cadmium and salinity stresses in coastal wetlands affected by reclamation and urbanization based on indoor and outdoor experiments

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Junhong, E-mail: junhongbai@163.com; Huang, Laibin, E-mail: seahuanglaibin@gmail.com; Gao, Zhaoqin; Lu, Qiongqiong; Wang, Junjing; Zhao, Qingqing

    2014-09-15

    Highlights: • A higher germination rate of soil seed bank was observed in the indoor experiment. • The outdoor experiment showed larger number and destiny of germinated seedlings. • Urbanization had greater impacts on soil seed banks than wetland reclamation. • Soil seed banks for wetland restoration were more suitable in the reclaimed region. • Suitable salt or Cd levels could activate seedling emergence in the soil seed bank. - Abstract: Indoor and outdoor seedling emergence experiments were conducted to thoroughly investigate germination patterns as affected by reclamation and urbanization, the ecological characteristics of soil seed banks, and their relationships with environmental factors in both urbanized and reclaimed regions of the Pearl River Delta in coastal wetlands. The germination rate of the soil seed bank was higher in the indoor experiment compared with that in the outdoor experiment, whereas the number and destiny of the germinated seedlings were greater in the outdoor experiment. The species diversity and number, as well as the richness and evenness indices, were higher in the urbanized region compared with the reclaimed region. However, the dominance and Sørensen similarity indices were greater in the reclaimed region compared with those indices in the urbanized region. Higher salinity and Cadmium (Cd) levels could inhibit seed germination; however, their suitable ranges (i.e. [0–2000 mg kg{sup −1}] for salinity and [0–4.0 mg kg{sup −1}] for available Cd) can activate seedling emergence, and more seedlings germinated under the intersectional levels at 0.34 mg kg{sup −1} available Cd and 778.6 mg kg{sup −1} salinity. Seawater intrusion caused by the sea level rise will possibly result in the salt-tolerant community in this area due to increasing salinity.

  10. Soil seed banks and their germination responses to cadmium and salinity stresses in coastal wetlands affected by reclamation and urbanization based on indoor and outdoor experiments

    International Nuclear Information System (INIS)

    Bai, Junhong; Huang, Laibin; Gao, Zhaoqin; Lu, Qiongqiong; Wang, Junjing; Zhao, Qingqing

    2014-01-01

    Highlights: • A higher germination rate of soil seed bank was observed in the indoor experiment. • The outdoor experiment showed larger number and destiny of germinated seedlings. • Urbanization had greater impacts on soil seed banks than wetland reclamation. • Soil seed banks for wetland restoration were more suitable in the reclaimed region. • Suitable salt or Cd levels could activate seedling emergence in the soil seed bank. - Abstract: Indoor and outdoor seedling emergence experiments were conducted to thoroughly investigate germination patterns as affected by reclamation and urbanization, the ecological characteristics of soil seed banks, and their relationships with environmental factors in both urbanized and reclaimed regions of the Pearl River Delta in coastal wetlands. The germination rate of the soil seed bank was higher in the indoor experiment compared with that in the outdoor experiment, whereas the number and destiny of the germinated seedlings were greater in the outdoor experiment. The species diversity and number, as well as the richness and evenness indices, were higher in the urbanized region compared with the reclaimed region. However, the dominance and Sørensen similarity indices were greater in the reclaimed region compared with those indices in the urbanized region. Higher salinity and Cadmium (Cd) levels could inhibit seed germination; however, their suitable ranges (i.e. [0–2000 mg kg −1 ] for salinity and [0–4.0 mg kg −1 ] for available Cd) can activate seedling emergence, and more seedlings germinated under the intersectional levels at 0.34 mg kg −1 available Cd and 778.6 mg kg −1 salinity. Seawater intrusion caused by the sea level rise will possibly result in the salt-tolerant community in this area due to increasing salinity

  11. Estimation of occupational and nonoccupational nitrogen dioxide exposure for Korean taxi drivers using a microenvironmental model

    International Nuclear Information System (INIS)

    Son, Busoon; Yang, Wonho; Breysse, Patrick; Chung, Taewoong; Lee, Youngshin

    2004-01-01

    Occupational and nonoccupational personal nitrogen dioxide (NO 2 ) exposures were measured using passive samplers for 31 taxi drivers in Asan and Chunan, Korea. Exposures were also estimated using a microenvironmental time-weighted average model based on indoor, outdoor and inside the taxi area measurements. Mean NO 2 indoor and outdoor concentrations inside and outside the taxi drivers' houses were 24.7±10.7 and 23.3±8.3 ppb, respectively, with a mean indoor to outdoor NO 2 ratio of 1.1. Mean personal NO 2 exposure of taxi drivers was 30.3±9.7 ppb. Personal NO 2 exposures for drivers were more strongly correlated with interior vehicle NO 2 levels (r=0.89) rather than indoor residential NO 2 levels (r=0.74) or outdoor NO 2 levels (r=0.71). The main source of NO 2 exposure for taxi drivers was considered to be occupational driving. Interestingly, the NO 2 exposures for drivers' using LPG-fueled vehicles (26.3±1.3 ppb) were significantly lower than those (38.1±1.3 ppb) using diesel-fueled vehicle (P 2 exposure with indoor and outdoor NO 2 levels of the residence, and interior vehicle NO 2 levels (P 2 levels because they drive diesel-using vehicles outdoors in Korea

  12. Dynamic modeling of human thermal comfort after the transition from an indoor to an outdoor hot environment.

    Science.gov (United States)

    Katavoutas, George; Flocas, Helena A; Matzarakis, Andreas

    2015-02-01

    Thermal comfort under non-steady-state conditions primarily deals with rapid environmental transients and significant alterations of the meteorological conditions, activity, or clothing pattern within the time scale of some minutes. In such cases, thermal history plays an important role in respect to time, and thus, a dynamic approach is appropriate. The present study aims to investigate the dynamic thermal adaptation process of a human individual, after his transition from a typical indoor climate to an outdoor hot environment. Three scenarios of thermal transients have been considered for a range of hot outdoor environmental conditions, employing the dynamic two-node IMEM model. The differences among them concern the radiation field, the activity level, and the body position. The temporal pattern of body temperatures as well as the range of skin wettedness and of water loss have been investigated and compared among the scenarios and the environmental conditions considered. The structure and the temporal course of human energy fluxes as well as the identification of the contribution of body temperatures to energy fluxes have also been studied and compared. In general, the simulation results indicate that the response of a person, coming from the same neutral indoor climate, varies depending on the scenario followed by the individual while being outdoors. The combination of radiation field (shade or not) with the kind of activity (sitting or walking) and the outdoor conditions differentiates significantly the thermal state of the human body. Therefore, 75% of the skin wettedness values do not exceed the thermal comfort limit at rest for a sitting individual under the shade. This percentage decreases dramatically, less than 25%, under direct solar radiation and exceeds 75% for a walking person under direct solar radiation.

  13. Investigation of infiltration and indoor air quality

    International Nuclear Information System (INIS)

    1990-03-01

    A multitask study was performed in the State of New York to provide information for guiding home energy conservation programs while maintaining acceptable indoor air quality. During the study, the statistical distribution of radon concentrations inside 2,400 homes was determined. The relationships among radon levels, house characteristics, and sources were also investigated. The direct impact that two specific air infiltration reduction measures--caulking and weatherstripping of windows and doors, and installation of storm windows and storm doors--have on house air leakage was investigated in 60 homes. The effect of house age on the impact of weatherization was also evaluated. Indoor and outdoor measurements of NO 2 , CO, SO 2 , and respirable suspended particulates (RSP) were made for 400 homes to determine the effect of combustion sources on indoor air quality and to characterize the statistical distribution of the concentrations. Finally, the combustion source data were combined with the information on air infiltration reduction measures to estimate the potential impact of these measures on indoor air quality

  14. Indoor and Outdoor Exposure to Ultrafine, Fine and Microbiologically Derived Particulate Matter Related to Cardiovascular and Respiratory Effects in a Panel of Elderly Urban Citizens

    Directory of Open Access Journals (Sweden)

    Dorina Gabriela Karottki

    2015-02-01

    Full Text Available To explore associations of exposure to ambient and indoor air particulate and bio-aerosol pollutants with cardiovascular and respiratory disease markers, we utilized seven repeated measurements from 48 elderly subjects participating in a 4-week home air filtration study. Microvascular function (MVF, lung function, blood leukocyte counts, monocyte adhesion molecule expression, C-reactive protein, Clara cell protein (CC16 and surfactant protein-D (SPD were examined in relation to exposure preceding each measurement. Exposure assessment included 48-h urban background monitoring of PM10, PM2.5 and particle number concentration (PNC, weekly measurements of PM2.5 in living- and bedroom, 24-h measurements of indoor PNC three times, and bio-aerosol components in settled dust on a 2-week basis. Statistically significant inverse associations included: MVF with outdoor PNC; granulocyte counts with PM2.5; CD31 expression with dust fungi; SPD with dust endotoxin. Significant positive associations included: MVF with dust bacteria; monocyte expression of CD11 with PM2.5 in the bedroom and dust bacteria and endotoxin, CD31 expression with dust serine protease; serum CC16 with dust NAGase. Multiple comparisons demand cautious interpretation of results, which suggest that outdoor PNC have adverse effects on MVF, and outdoor and indoor PM2.5 and bio-aerosols are associated with markers of inflammation and lung cell integrity.

  15. Size fraction effect on phthalate esters accumulation, bioaccessibility and in vitro cytotoxicity of indoor/outdoor dust, and risk assessment of human exposure.

    Science.gov (United States)

    Wang, Wei; Wu, Fu-Yong; Huang, Min-Juan; Kang, Yuan; Cheung, Kwai Chung; Wong, Ming Hung

    2013-10-15

    Indoor and outdoor dusts from two urban centers in the Pearl River Delta, China, were analyzed and phthalate esters varied from 4.95 to 2,220 μg g(-1) in indoor dust, significantly higher than outdoor dust (1.70-869 μg g(-1)). Di-2-ethylhexyl phthalate (DEHP) was the dominant phthalate found and the highest distribution factor (DF) (1.56 ± 0.41) was noted in the human T cell lymphoblast leukemic cell line (CCRF-CEM) indicated by Lethal Concentration 50 (LC50) decreased with particle size. The power model was found as a better fit for explaining the relationship between LC50 and phthalates (R(2)=0.46, passessment indicated that indoor dust ingestion accounted for the major source for DEHP exposure (81.4-96.4% of non-dietary exposure and 36.5% of total exposure), especially for toddlers. The cancer risks associated with DEHP via home dust were high (10(-6)-10(-4)), with 10% of houses estimated with unacceptable risks (>10(-4)). After corrected with the bioaccessibility of phthalates, the cancer risks of dust exposure were moderate (10(-7)-10(-5)). Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Research Article Evaluation of different signal propagation models for a mixed indoor-outdoor scenario using empirical data

    Directory of Open Access Journals (Sweden)

    Oleksandr Artemenko

    2016-06-01

    Full Text Available In this paper, we are choosing a suitable indoor-outdoor propagation model out of the existing models by considering path loss and distance as parameters. A path loss is calculated empirically by placing emitter nodes inside a building. A receiver placed outdoors is represented by a Quadrocopter (QC that receives beacon messages from indoor nodes. As per our analysis, the International Telecommunication Union (ITU model, Stanford University Interim (SUI model, COST-231 Hata model, Green-Obaidat model, Free Space model, Log-Distance Path Loss model and Electronic Communication Committee 33 (ECC-33 models are chosen and evaluated using empirical data collected in a real environment. The aim is to determine if the analytically chosen models fit our scenario by estimating the minimal standard deviation from the empirical data.

  17. Using big data from air quality monitors to evaluate indoor PM2.5 exposure in buildings: Case study in Beijing.

    Science.gov (United States)

    Zuo, JinXing; Ji, Wei; Ben, YuJie; Hassan, Muhammad Azher; Fan, WenHong; Bates, Liam; Dong, ZhaoMin

    2018-05-19

    Due to time- and expense- consuming of conventional indoor PM 2.5 (particulate matter with aerodynamic diameter of less than 2.5 μm) sampling, the sample size in previous studies was generally small, which leaded to high heterogeneity in indoor PM 2.5 exposure assessment. Based on 4403 indoor air monitors in Beijing, this study evaluated indoor PM 2.5 exposure from 15th March 2016 to 14th March 2017. Indoor PM 2.5 concentration in Beijing was estimated to be 38.6 ± 18.4 μg/m 3 . Specifically, the concentration in non-heating season was 34.9 ± 15.8 μg/m 3 , which was 24% lower than that in heating season (46.1 ± 21.2 μg/m 3 ). A significant correlation between indoor and ambient PM 2.5 (p < 0.05) was evident with an infiltration factor of 0.21, and the ambient PM 2.5 contributed approximately 52% and 42% to indoor PM 2.5 for non-heating and heating seasons, respectively. Meanwhile, the mean indoor/outdoor (I/O) ratio was estimated to be 0.73 ± 0.54. Finally, the adjusted PM 2.5 exposure level integrating the indoor and outdoor impact was calculated to be 46.8 ± 27.4 μg/m 3 , which was approximately 42% lower than estimation only relied on ambient PM 2.5 concentration. This study is the first attempt to employ big data from commercial air monitors to evaluate indoor PM 2.5 exposure and risk in Beijing, which may be instrumental to indoor PM 2.5 pollution control. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Indoor air pollution

    International Nuclear Information System (INIS)

    Spengler, J.D.

    1985-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  19. Exploring the consequences of climate change for indoor air quality

    International Nuclear Information System (INIS)

    Nazaroff, William W

    2013-01-01

    Climate change will affect the concentrations of air pollutants in buildings. The resulting shifts in human exposure may influence public health. Changes can be anticipated because of altered outdoor pollution and also owing to changes in buildings effected in response to changing climate. Three classes of factors govern indoor pollutant levels in occupied spaces: (a) properties of pollutants; (b) building factors, such as the ventilation rate; and (c) occupant behavior. Diversity of indoor conditions influences the public health significance of climate change. Potentially vulnerable subpopulations include not only the young and the infirm but also those who lack resources to respond effectively to changing conditions. Indoor air pollutant levels reflect the sum of contributions from indoor sources and from outdoor pollutants that enter with ventilation air. Pollutant classes with important indoor sources include the byproducts of combustion, radon, and volatile and semivolatile organic compounds. Outdoor pollutants of special concern include particulate matter and ozone. To ensure good indoor air quality it is important first to avoid high indoor emission rates for all pollutants and second to ensure adequate ventilation. A third factor is the use of air filtration or air cleaning to achieve further improvements where warranted. (letter)

  20. Association between indoor and outdoor air pollution and adolescent asthma from 1995 to 1996 in Taiwan

    Energy Technology Data Exchange (ETDEWEB)

    Wang, T.N.; Ko, Y.C.; Chao, Y.Y.; Huang, C.C.; Lin, R.S.

    1999-10-01

    The study aim was to estimate the contribution of indoor and outdoor air pollution to the 1-year prevalence of adolescent asthma after personal susceptibility and other potential risk factors were taken into account. A large-scaled cross-sectional study was conducted among 165,173 high school students aged 11 to 16 years in the different communities of Kaohsiung and Pintong in Taiwan, from October 1995 to June 1996. Each student and his/her parents participating in the study completed a video and a written International Study of Asthma and Allergies in Childhood questionnaire about symptoms of wheezing and allergies, passive smoking, and demographic variables. After adjustment for potential confounders, adolescents exposed to cigarette smoking and environmental tobacco smoke were found to suffer from asthma at an increased frequency. The authors observed a statistically significant association between outdoor air pollution and asthma, after controlling for potential confound variables. Total suspended particulate, nitrogen dioxide, carbon monoxide, ozone, and airborne dust particles all displayed an independent association with asthma, respectively. There were no selection biases in this community-based study, which provides evidence that passive smoking and long-term, high average outdoor air pollution are independent risk factors of asthma.

  1. Sex differences in circumstances and consequences of outdoor and indoor falls in older adults in the MOBILIZE Boston cohort study

    Science.gov (United States)

    2013-01-01

    Background Despite extensive research on risk factors associated with falling in older adults, and current fall prevention interventions focusing on modifiable risk factors, there is a lack of detailed accounts of sex differences in risk factors, circumstances and consequences of falls in the literature. We examined the circumstances, consequences and resulting injuries of indoor and outdoor falls according to sex in a population study of older adults. Methods Men and women 65 years and older (N = 743) were followed for fall events from the Maintenance of Balance, Independent Living, Intellect, and Zest in the Elderly (MOBILIZE) Boston prospective cohort study. Baseline measurements were collected by comprehensive clinical assessments, home visits and questionnaires. During the follow-up (median = 2.9 years), participants recorded daily fall occurrences on a monthly calendar, and fall circumstances were determined by a telephone interview. Falls were categorized by activity and place of falling. Circumstance-specific annualized fall rates were calculated and compared between men and women using negative binomial regression models. Results Women had lower rates of outdoor falls overall (Crude Rate Ratio (RR): 0.72, 95% Confidence Interval (CI): 0.56-0.92), in locations of recreation (RR: 0.34, 95% CI: 0.17-0.70), during vigorous activity (RR: 0.38, 95% CI: 0.18-0.81) and on snowy or icy surfaces (RR: 0.55, 95% CI: 0.36-0.86) compared to men. Women and men did not differ significantly in their rates of falls outdoors on sidewalks, streets, and curbs, and during walking. Compared to men, women had greater fall rates in the kitchen (RR: 1.88, 95% CI: 1.04-3.40) and while performing household activities (RR: 3.68, 95% CI: 1.50-8.98). The injurious outdoor fall rates were equivalent in both sexes. Women’s overall rate of injurious indoor falls was nearly twice that of men’s (RR: 1.98, 95% CI: 1.44-2.72), especially in the kitchen (RR: 6.83, 95% CI: 2

  2. Matrix vaccination guidelines : 2015 ABCD recommendations for indoor/outdoor cats, rescue shelter cats and breeding catteries

    NARCIS (Netherlands)

    Hosie, Margaret J; Addie, Diane D; Boucraut-Baralon, Corine; Egberink, Herman; Frymus, Tadeusz; Gruffydd-Jones, Tim; Hartmann, Katrin; Horzinek, Marian C; Lloret, Albert; Lutz, Hans; Marsilio, Fulvio; Pennisi, Maria Grazia; Radford, Alan D; Thiry, Etienne; Truyen, Uwe; Möstl, Karin

    OVERVIEW: In 2013, the ABCD published 'Matrix vaccination guidelines: ABCD recommendations for indoor/outdoor cats, rescue shelter cats and breeding catteries' in a Special Issue of the Journal of Feline Medicine and Surgery (Volume 15, Issue 7, pages 540-544). The ABCD's vaccination recommendations

  3. Indoor Air Quality Assessment of Elementary Schools in Curitiba, Brazil

    International Nuclear Information System (INIS)

    Godoi, R. H. M.; Avigo, D.; Campos, V. P.; Tavares, T. M.; Marchi, M. R. R. de; Grieken, R. Van; Godoi, A. F. L.

    2009-01-01

    The promotion of good indoor air quality in schools is of particular public concern for two main reasons: (1) school-age children spend at least 30% of their time inside classrooms and (2) indoor air quality in urban areas is substantially influenced by the outdoor pollutants, exposing tenants to potentially toxic substances. Two schools in Curitiba, Brazil, were selected to characterize the gaseous compounds indoor and outdoor of the classrooms. The concentrations of benzene, toluene, ethylbenzene, and the isomers xylenes (BTEX); NO 2 ; SO 2 ; O 3 ; acetic acid (HAc); and formic acid (HFor) were assessed using passive diffusion tubes. BTEX were analyzed by gas chromatography-ion trap mass spectrometry and other collected gasses by ion chromatography. The concentration of NO 2 varied between 9.5 and 23 μg m -3 , whereas SO 2 showed an interval from 0.1 to 4.8 μg m -3 . Within the schools, BTEX concentrations were predominant. Formic and acetic acids inside the classrooms revealed intermediate concentrations of 1.5 μg m -3 and 1.2 μg m -3 , respectively.

  4. Potential exposures associated with indoor marijuana growing operations.

    Science.gov (United States)

    Martyny, John W; Serrano, Kate A; Schaeffer, Joshua W; Van Dyke, Mike V

    2013-01-01

    We entered a total of 30 indoor marijuana grow operations (IMGO) with law enforcement investigators in order to determine potential exposures to first responders. Samples for airborne fungal spores, volatile organic compounds, carbon dioxide, carbon monoxide, and delta-9-tetrahydrocannabinol (THC) were obtained as well as the identification of chemicals utilized in the IMGO. The chemicals utilized within the IMGOs were primarily pesticides and fertilizers with none showing high toxicity. Although several of the IMGOs had CO2 enrichment processes involving combustion, CO levels were not elevated. THC levels were identified on surfaces within the IMGOs and on the hands of the investigators. Surface levels ranged from indoor and outdoor samples with Cladosporium sp. the predominant outdoor species and Penicillium sp. the predominant indoor species. We concluded that the potential increase in fungal spore concentrations associated with the investigation and especially removal of the marijuana plants could potentially expose responders to levels of exposure consistent with those associated with mold remediation processes and that respiratory protection is advisable.

  5. Source apportionment for indoor PM2.5 and elemental concentrations using by a positive matrix factorization and an instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Lim, Jong Myoung; Moon, Jong Hwa; Chung, Yong Sam; Jung, Byoung Won; Lee, Jin Hong

    2009-01-01

    Airborne particulate matters, especially the PM2.5 (aerodynamic equivalent diameter, AED, less than 2.5 μm) fraction has been important. This is because of their potential for deposition on to the human respiratory system being accompanied by many harmful trace metals (such as As, Cd, Cr, Cu, Mn, Pb, Se, and Zn). The indoor air quality has become a great concern since late 1980s, because the population spends a majority of their time in various indoor environments. The indoor particulate matter may be influenced from outdoor environment and indoor sources such as environmental tobacco smoke (ETS), combustion devices, cooking, etc. In this study, we undertake the measurements of about 26 elements using instrumental neutron activation analysis (INAA). Based on our measurement data, we characterize concentration status and mutual relationship between indoor and adjacent outdoor air quality. Next, sources at indoor/outdoor environment were identified and the contributions of each source were quantified by positive matrix factorization (PMF)

  6. Measurements of children's exposures to particles and nitrogen dioxide in Santiago, Chile

    International Nuclear Information System (INIS)

    Rojas-Bracho, Leonora; Suh, Helen H.; Koutrakis, Petros; Oyola, Pedro

    2002-01-01

    An exposure study of children (aged 10-12 years) living in Santiago, Chile, was conducted. Personal, indoor and outdoor fine and inhalable particulate matter ( 2.5 and 10 , respectively), and nitrogen dioxide (NO 2 ) were measured during pilot (N=8) and main (N=20) studies, which were conducted during the winters of 1998 and 1999, respectively. For the main study, personal indoor and outdoor 24-h samples were collected for five consecutive days. Similar mean personal, indoor and outdoor PM 2.5 concentrations (69.5, 68.5 and 68.1 μg m -3 , respectively) were found. However, for coarse particles (calculated as the difference between measured PM 10 and PM 2.5 , PM 2.5-10 ) indoor and outdoor levels (35.4 and 47.4 μg m -3 ) were lower than their corresponding personal exposures (76.3 μg m -3 ). Indoor and outdoor NO 2 concentrations were comparable (35.8 and 36.9 ppb) and higher than personal exposures (25.9 ppb). Very low ambient indoor and personal O 3 levels were found, which were mostly below the method's limit of detection (LOD). Outdoor particles contributed significantly to indoor concentrations, with effective penetration efficiencies of 0.61 and 0.30 for PM 2.5 and PM 2.5-10 , respectively. Personal exposures were strongly associated with indoor and outdoor concentrations for PM 2.5 , but weakly associated for PM 2.5-10 . For NO 2 , weak associations were obtained for indoor-outdoor and personal-outdoor relationships. This is probably a result of the presence of gas cooking stoves in all the homes. Median I/O, P/I and P/O ratios for PM 2.5 were close to unity, and for NO 2 they ranged between 0.64 and 0.95. These ratios were probably due to high ambient PM 2.5 and NO 2 levels in Santiago, which diminished the relative contribution of indoor sources and subjects' activities to indoor and personal PM 2.5 and NO 2 levels

  7. TOWARDS A FAST, LOW-COST INDOOR MAPPING AND POSITIONING SYSTEM FOR CIVIL PROTECTION AND EMERGENCY TEAMS

    Directory of Open Access Journals (Sweden)

    E. Angelats

    2017-11-01

    Full Text Available Civil protection and emergency teams work usually under very risky conditions that endanger their lives. One of the factors contributing to such risks is the lack of knowledge about their physical environment, especially when working indoors. Mapping and location indoor and outdoor technologies exist; for outdoors, very good levels of precision and accuracy may be obtained using offthe- shelf equipment; on the other side, and although good solutions for indoor environments are available, these require some extra pre-deployed infrastructure in the area to navigate, which is unacceptable in the case of emergency teams. It may be said, then, that no mature indoor + outdoor integrated solution providing the appropriate precision and accuracy for the purposes of emergency teams exist. In this paper, the assessment of a set of currently available sensors (IMUs, RGB-D cameras, GNSS receivers and algorithms is presented to show that it is already possible to build such a solution relying on them – providing that appropriate (indoor lightning and texture conditions exist.

  8. Indoor environment and allergy except housedust mite; Jukankyo to allergy ni kansuru dani igai no chosa kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, F.; Nishima, S.

    1998-05-31

    Pathopoiesis factors of allergic diseases include immune antibody productivity sthenia reacting with antigens such as mite or the like in allergy reaction which is regarded as based on genetic fact (atopic diathesis), and environmental factors as external factors. The environmental factors are further classified into specific factors (antigens) and nonspecific factors. The former factors include the indoor factors such as mite, mould, animals bred indoor, etc., and outdoor factors such as pollen and so on. The latter factors include indoor factors such as passive smoking, carbon monoxide, nitrogen oxides, formaldehyde, etc., and outdoor factors such as sulfur oxides, nitrogen oxides, airborne particles and so on. In this paper, the environmental factors in relation to allergic diseases expect mite are introduced. Besides mould, cockroach/insect, fur dust and dandruff of animals, adjustment of room temperature/humidity, smoking, indoor and outdoor air pollution are mentioned as the environmental factors expect mite, and the cause-effect relations thereof are explained. 24 refs., 3 figs., 7 tabs.

  9. The importance of determining the air exchange rate in flats and buildings for calculations of the averted indoor inhalation doses arising from contaminated outdoor air

    International Nuclear Information System (INIS)

    Jilek, Karel; Thomas, J.; Bulanek, B.; Lenk, J.; Marikova, S.

    2015-01-01

    The indoor-outdoor air exchange rate is an important parameter when refining estimates of the averted inhaled doses to population in houses and buildings after an emergency event resulting in contamination of outdoor air with a radioactive material. The air exchange rates measured in 70 occupied houses and in 20 unoccupied houses using N 2 O as the tracer gas are presented, and the results of modelling the averted doses in the residential buildings for both gaseous and aerosol outdoor contaminants are demonstrated. (orig.)

  10. Indoor Semantic Modelling for Routing: The Two-Level Routing Approach for Indoor Navigation

    Directory of Open Access Journals (Sweden)

    Liu Liu

    2017-11-01

    for the logical network can exclude unrelated spaces and then derive geometric paths more efficiently. In this thesis, two options are proposed for routing just on the logical network, three options are proposed for routing just on the geometric networks, and seven options for two-level routing. On the logical network, six routing criteria are proposed and three human wayfinding strategies are adopted to simulate human indoor behaviours. According to a specific criterion, space semantics of logical nodes is utilized to assign different weights to logical nodes and edges. Therefore, routing on the logical network can be accomplished by applying the Dijkstra algorithm. If multiple criteria are adopted, an order of criteria is applied for routing according to a specific user. In this way, logical paths can be computed as a sequence of indoor spaces with clear semantics. On geometric networks, this thesis proposes a new routing method to provide detailed paths avoiding indoor obstacles with respect to pedestrian sizes. This method allows geometric networks to be derived for individual users with different sizes for any specified spaces. To demonstrate the use of the two types of network, this thesis tests routing on one level (the logical or the geometric network. Four case studies about the logical network are presented in both simple and complex buildings. In the simple building, no multiple paths lie between spaces A and B, but in the complex buildings, multiple logical paths exist and the candidate paths can be reduced by applying these routing criteria in an order for a user. The relationships of these criteria to user profiles are assumed in this thesis. The proposed geometric routing regarding user sizes is tested with three case studies: 1 routing for pedestrians with two distinct sizes in one space; 2 routing for pedestrians with changed sizes in one space; and 3 a larger geometric network formed by the ones in a given sequence of spaces. The first case shows

  11. Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Price, P.N.; Shehabi, A.; Chan, R.W.; Gadgil, A.J.

    2006-06-01

    We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

  12. Indoor air-quality measurements in energy-efficient residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Berk, J.V.; Hollowell, C.D.; Pepper, J.H.; Young, R.

    1980-05-01

    The potential impact on indoor air quality of energy-conserving measures that reduce ventilation is being assessed in a field-monitoring program conducted by the Lawrence Berkeley Laboratory. Using a mobile laboratory, on-site monitoring of infiltration rate, carbon dioxide, carbon monoxide, nitrogen dioxide, nitric oxide, ozone, sulfur dioxide, formaldehyde, total aldehydes, and particulates was conducted in three houses designed to be energy-efficient. Preliminary results show that energy-conserving design features that reduce air-exchange rates compromise indoor air quality; specifically, indoor levels of several pollutants were found to exceed levels detected outdoors. Although the indoor levels of most pollutants are within limits established by present outdoor air-quality standards, considerable work remains to be accomplished before health-risk effects can be accurately assessed and broad-scale regulatory guidelines revised to comply with energy-conservation goals.

  13. The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Reda, Ibrahim; Robinson, Justin

    2016-07-01

    Accurate solar radiation data sets are critical to reducing the expenses associated with mitigating performance risk for solar energy conversion systems, and they help utility planners and grid system operators understand the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of calibration methodologies and the resulting calibration responsivities provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these radiometers are calibrated indoors, and some are calibrated outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The reference radiometer calibrations are traceable to the World Radiometric Reference. These different methods of calibration demonstrated 1% to 2% differences in solar irradiance measurement. Analyzing these values will ultimately assist in determining the uncertainties of the radiometer data and will assist in developing consensus on a standard for calibration.

  14. Continual monitoring of radon decay products concentration in indoor and outdoor air

    International Nuclear Information System (INIS)

    Petruf, P.; Holy, K.; Stanys, T.

    1998-01-01

    The goal of this work was the development of the method and construction and testing of measurement device for continual monitoring of radon daughters concentrations in the indoor and outdoor environment with regard to make possible to determine very low activities in the outdoor air (below % Bq/m 3 ). In this method air sample is drawn through the appropriate filter material. Radon and thoron daughters both attached and unattached on aerosols particles are collected on the filter surface and then the filter activity is counted. The silicon surface barrier detector with the active area of 200 mm 2 in monitor was used. The Millipore AW19-type filter was chosen and sampling rate of 30 l/min for collecting of the air samples. The determination of the individual activity concentrations in three-count method is based on the solution of the simultaneous equations describing the number of atoms of measured nuclides on the filter during and after sampling. The monitor was tested in three different environments (the average values of the activity concentrations of radon and its decay products in Bq/m 3 are given): in the basement of the building: 61.4 ± 5.0 of 222 Rn, 29.5 ± 2.8 of 218 Po, 14.1 ± 1.8 of 214 Pb and 12.1 ± 1.6 of 214 Bi; in the room on the second floor of the same building:22.2 ± 7.9 of 222 Rn, 7.3 ± 2.8 of 218 Po, 4.6 ± 1.9 of 214 Pb and 2.6 ± 1.2 of 214 Bi ; in the outdoor air in front of the building: 4.1 ± 2.7 of 222 Rn, 2.3 ± 0.9 of 218 Po, 1.5 ± 0.8 of 214 Pb and 1.4 ± 0.6 of 214 Bi. The results show a good agreement with expectations of the activity concentrations in three different environments. The monitor enables to determine low activity concentrations in the outdoor with an acceptable precision during one hour counting. The monitor can be used for the research of the correlation between the atmospheric stability and activity concentrations of radon decay products

  15. Workload comparison between hiking and indoor physical activity.

    Science.gov (United States)

    Fattorini, Luigi; Pittiglio, Giancarlo; Federico, Bruno; Pallicca, Anastasia; Bernardi, Marco; Rodio, Angelo

    2012-10-01

    Walking is a physical activity able to maintain and improve aerobic fitness. This activity can easily be performed in all seasons both outdoors and indoors, but when it is performed in its natural environment, the use of specific equipment is required. In particular, it has been demonstrated that the use of trekking boots (TBs) induces a larger workload than those used indoors. Because an adequate fitness level is needed to practice hiking in safety, it is useful to know the energy demand of such an activity. This research aims at defining the metabolic engagement of hiking on natural paths with specific equipment at several speeds and comparing this with indoor ones (on a treadmill). This can thence be used to define the load that better reflects the one required to walk on natural paths. The walking energy cost (joules per kilogram per meter) at several speeds (0.28, 0.56, 0.84, 1.11, and 1.39 m·s(-1))-on level natural terrain while wearing suitable footwear (TBs) and on a treadmill at various raising slopes (0, 1, 2, 3, 4%) while wearing running shoes-was measured in 14 healthy young men (age 23.9 ± 2.9 years, stature 1.75 ± 0.04 m, and body mass 72.9 ± 6.3 kg). A physiological evaluation of all the subjects was performed before energy cost measurements. The results showed that outdoors, the oxygen uptake was consistently less than the ventilatory threshold at all speeds tested and that a 3% slope on the treadmill best reflects the outdoor walking energy expenditure. These findings will prove useful to plan proper training for hiking activity or mixed (outdoors and indoors) training program.

  16. Indoor Air Pollution (Environmental Health Student Portal)

    Science.gov (United States)

    ... Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ... Pollution Indoor Air Pollution Print this Page Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ...

  17. A kinetic analysis of manual wheelchair propulsion during start-up on select indoor and outdoor surfaces

    NARCIS (Netherlands)

    Koontz, AM; Cooper, RA; Boninger, ML; Yang, YS; Impink, BG; van der Woude, LHV

    2005-01-01

    The objective of this study was to conduct a kinetic analysis of manual wheelchair propulsion during start-LIP on select indoor and Outdoor surfaces. Eleven manual wheelchairs were fitted with a SMART(Wheel) and their users were asked to Push on a Course consisting of high- and low-pile carpet,

  18. Psychotropic substances in indoor environments.

    Science.gov (United States)

    Cecinato, Angelo; Romagnoli, Paola; Perilli, Mattia; Patriarca, Claudia; Balducci, Catia

    2014-10-01

    The presence of drugs in outdoor air has been established, but few investigations have been conducted indoors. This study focused on psychotropic substances (PSs) at three schools, four homes and one office in Rome, Italy. The indoor drug concentrations and the relationships with the outdoor atmosphere were investigated. The optimised monitoring procedure allowed for the determination of cocaine, cannabinoids and particulate fractions of nicotine and caffeine. In-field experiments were performed during the winter, spring and summer seasons. Psychotropic substances were observed in all indoor locations. The indoor concentrations often exceeded those recorded both outdoors at the same sites and at the atmospheric pollution control network stations, indicating that the drugs were released into the air at the inside sites or were more persistent. During winter, the relative concentrations of cannabinol, cannabidiol and tetrahydrocannabinol depended on site and indoor/outdoor location at the site. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. The relationship between perceived health and physical activity indoors, outdoors in built environments, and outdoors in nature.

    Science.gov (United States)

    Pasanen, Tytti P; Tyrväinen, Liisa; Korpela, Kalevi M

    2014-11-01

    A body of evidence shows that both physical activity and exposure to nature are connected to improved general and mental health. Experimental studies have consistently found short term positive effects of physical activity in nature compared with built environments. This study explores whether these benefits are also evident in everyday life, perceived over repeated contact with nature. The topic is important from the perspectives of city planning, individual well-being, and public health. National survey data (n = 2,070) from Finland was analysed using structural regression analyses. Perceived general health, emotional well-being, and sleep quality were regressed on the weekly frequency of physical activity indoors, outdoors in built environments, and in nature. Socioeconomic factors and other plausible confounders were controlled for. Emotional well-being showed the most consistent positive connection to physical activity in nature, whereas general health was positively associated with physical activity in both built and natural outdoor settings. Better sleep quality was weakly connected to frequent physical activity in nature, but the connection was outweighed by other factors. The results indicate that nature provides an added value to the known benefits of physical activity. Repeated exercise in nature is, in particular, connected to better emotional well-being. © 2014 The Authors. Applied Psychology: Health and Well-Being published by John Wiley & Sons Ltd on behalf of The International Association of Applied Psychology.

  20. Quantitative assessments of indoor air pollution and the risk of childhood acute leukemia in Shanghai

    International Nuclear Information System (INIS)

    Gao, Yu; Zhang, Yan; Kamijima, Michihiro; Sakai, Kiyoshi; Khalequzzaman, Md; Nakajima, Tamie; Shi, Rong; Wang, Xiaojin; Chen, Didi; Ji, Xiaofan; Han, Kaiyi; Tian, Ying

    2014-01-01

    We investigated the association between indoor air pollutants and childhood acute leukemia (AL). A total of 105 newly diagnosed cases and 105 1:1 gender-, age-, and hospital-matched controls were included. Measurements of indoor pollutants (including nitrogen dioxide (NO 2 ) and 17 types of volatile organic compounds (VOCs)) were taken with diffusive samplers for 64 pairs of cases and controls. Higher concentrations of NO 2 and almost half of VOCs were observed in the cases than in the controls and were associated with the increased risk of childhood AL. The use of synthetic materials for wall decoration and furniture in bedroom was related to the risk of childhood AL. Renovating the house in the last 5 years, changing furniture in the last 5 years, closing the doors and windows overnight in the winter and/or summer, paternal smoking history and outdoor pollutants affected VOC concentrations. Our results support the association between childhood AL and indoor air pollution. - Highlights: • We firstly assessed the effects of indoor air pollution on childhood AL in China. • Indoor air pollutants were assessed by questionnaire and quantitative measurements. • NO 2 and 17 types of VOCs were measured in bedrooms of both cases and controls. • Higher concentrations of indoor air pollutants increased the risk of childhood AL. • Indoor behavioral factors and outdoor pollution might affect indoor air pollution. - Higher concentrations of indoor air pollutants were related to an elevated risk of childhood AL

  1. [Health evaluation of fine particulate matter in indoor air].

    Science.gov (United States)

    2008-11-01

    When evaluating the health effects of indoor air fine particulate matter, the indoor dynamics as well as the physical, chemical and biological properties of fine particles have to be considered. The indoor air fraction PM2.5 largely stems from outdoor air. Accordingly, the German Working Group on Indoor Guideline Values of the Federal Environmental Agency and the States' Health Authorities also recommends WHO's (2006) 24-hour mean guideline value of 25 microg PM2,5 per cubic meter for indoor air evaluation. In contrast to PM2.5, coarse particles (PM10) in schools, kindergartens and dwellings show much higher indoor air concentrations. Additional sources indoors have to be assumed. Because of the different composition of indoor air compared to outdoor air and due to the lack of dose-response relationships of coarse particles in indoor air, the health effects of indoor air PM10 can not be evaluated yet. Sufficient and consistent ventilation is an indispensable basis to reduce PM concentrations in indoor spaces. Furthermore, known sources of PM indoors should be detected consequently and subsequently minimized.

  2. Summer indoor heat exposure and respiratory and cardiovascular distress calls in New York City, NY, U.S.

    Science.gov (United States)

    Uejio, C K; Tamerius, J D; Vredenburg, J; Asaeda, G; Isaacs, D A; Braun, J; Quinn, A; Freese, J P

    2016-08-01

    Most extreme heat studies relate outdoor weather conditions to human morbidity and mortality. In developed nations, individuals spend ~90% of their time indoors. This pilot study investigated the indoor environments of people receiving emergency medical care in New York City, NY, U.S., from July to August 2013. The first objective was to determine the relative influence of outdoor conditions as well as patient characteristics and neighborhood sociodemographics on indoor temperature and specific humidity (N = 764). The second objective was to determine whether cardiovascular or respiratory cases experience hotter and more humid indoor conditions as compared to controls. Paramedics carried portable sensors into buildings where patients received care to passively monitor indoor temperature and humidity. The case-control study compared 338 respiratory cases, 291 cardiovascular cases, and 471 controls. Intuitively, warmer and sunnier outdoor conditions increased indoor temperatures. Older patients who received emergency care tended to occupy warmer buildings. Indoor-specific humidity levels quickly adjusted to outdoor conditions. Indoor heat and humidity exposure above a 26 °C threshold increased (OR: 1.63, 95% CI: 0.98-2.68, P = 0.056), but not significantly, the proportion of respiratory cases. Indoor heat exposures were similar between cardiovascular cases and controls. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Evaluation of Indoor Radio Deployment Options in High-Rise Building

    DEFF Research Database (Denmark)

    Nguyen, Huan Cong; Wigard, Jeroen; Kovacs, Istvan

    2017-01-01

    to the increase of inter-cell interference (ICI). Increasing transmit power brings largest gain when the density of indoor cell is low, and the noise and/or outdoor interference is the dominant source of performance degradation. When analyzing performance gain of an ideal receiver-side Interference Cancellation......In this paper we set out to analyze the indoor capacity under a realistic high-rise building scenario. The study takes into consideration the number of indoor cells deployed per floor, different inter-site distances (ISDs), transmit power settings and outdoor macro interference levels. The outcome...

  4. Measurements of children's exposures to particles and nitrogen dioxide in Santiago, Chile

    Energy Technology Data Exchange (ETDEWEB)

    Rojas-Bracho, Leonora; Suh, Helen H.; Koutrakis, Petros [Harvard University, School of Public Health, 665 Huntington Avenue, 02115 Boston, MA (United States); Oyola, Pedro [Comision Nacional del Medio Ambiente CONAMA, Santiago (Chile)

    2002-03-27

    An exposure study of children (aged 10-12 years) living in Santiago, Chile, was conducted. Personal, indoor and outdoor fine and inhalable particulate matter (<2.5 {mu}m in diameter, PM{sub 2.5} and <10 {mu}m in diameter, PM{sub 10}, respectively), and nitrogen dioxide (NO{sub 2}) were measured during pilot (N=8) and main (N=20) studies, which were conducted during the winters of 1998 and 1999, respectively. For the main study, personal indoor and outdoor 24-h samples were collected for five consecutive days. Similar mean personal, indoor and outdoor PM{sub 2.5} concentrations (69.5, 68.5 and 68.1 {mu}g m{sup -3}, respectively) were found. However, for coarse particles (calculated as the difference between measured PM{sub 10} and PM{sub 2.5}, PM{sub 2.5-10}) indoor and outdoor levels (35.4 and 47.4 {mu}g m{sup -3}) were lower than their corresponding personal exposures (76.3 {mu}g m{sup -3}). Indoor and outdoor NO{sub 2} concentrations were comparable (35.8 and 36.9 ppb) and higher than personal exposures (25.9 ppb). Very low ambient indoor and personal O{sub 3} levels were found, which were mostly below the method's limit of detection (LOD). Outdoor particles contributed significantly to indoor concentrations, with effective penetration efficiencies of 0.61 and 0.30 for PM{sub 2.5} and PM{sub 2.5-10}, respectively. Personal exposures were strongly associated with indoor and outdoor concentrations for PM{sub 2.5}, but weakly associated for PM{sub 2.5-10}. For NO{sub 2}, weak associations were obtained for indoor-outdoor and personal-outdoor relationships. This is probably a result of the presence of gas cooking stoves in all the homes. Median I/O, P/I and P/O ratios for PM{sub 2.5} were close to unity, and for NO{sub 2} they ranged between 0.64 and 0.95. These ratios were probably due to high ambient PM{sub 2.5} and NO{sub 2} levels in Santiago, which diminished the relative contribution of indoor sources and subjects' activities to indoor and personal PM

  5. Climate change and health: Indoor heat exposure in vulnerable populations

    International Nuclear Information System (INIS)

    White-Newsome, Jalonne L.; Sánchez, Brisa N.; Jolliet, Olivier; Zhang, Zhenzhen; Parker, Edith A.; Timothy Dvonch, J.; O'Neill, Marie S.

    2012-01-01

    Introduction: Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods: We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 in Detroit, MI. We used mixed linear regression to model indoor temperatures' responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results: Average maximum indoor temperature for all locations was 34.85 °C, 13.8 °C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions: Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings to improve heat exposure assessment for epidemiological investigations. Weatherizing homes and modifying home surroundings could mitigate indoor heat exposure among the elderly.

  6. Small-scale field evaluation of push-pull system against early- and outdoor-biting malaria mosquitoes in an area of high pyrethroid resistance in Tanzania [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Arnold S. Mmbando

    2017-11-01

    Full Text Available Background: Despite high coverage of indoor interventions like insecticide-treated nets, mosquito-borne infections persist, partly because of outdoor-biting, early-biting and insecticide-resistant vectors. Push-pull systems, where mosquitoes are repelled from humans and attracted to nearby lethal targets, may constitute effective complementary interventions. Methods: A partially randomized cross-over design was used to test efficacy of push-pull in four experimental huts and four local houses, in an area with high pyrethroid resistance in Tanzania. The push-pull system consisted of 1.1% or 2.2% w/v transfluthrin repellent dispensers and an outdoor lure-and-kill device (odour-baited mosquito landing box. Matching controls were set up without push-pull. Adult male volunteers collected mosquitoes attempting to bite them outdoors, but collections were also done indoors using exit traps in experimental huts and by volunteers in the local houses. The collections were done hourly (1830hrs-0730hrs and mosquito catches compared between push-pull and controls. An. gambiae s.l. and An. funestus s.l. were assessed by PCR to identify sibling species, and ELISA to detect Plasmodium falciparum and blood meal sources. Results: Push-pull in experimental huts reduced outdoor-biting for An. arabiensis and Mansonia species by 30% and 41.5% respectively. However, the reductions were marginal and insignificant for An. funestus (12.2%; p>0.05 and Culex (5%; p>0.05. Highest protection against all species occurred before 2200hrs. There was no significant difference in number of mosquitoes inside exit traps in huts with or without push-pull. In local households, push-pull significantly reduced indoor and outdoor-biting of An. arabiensis by 48% and 25% respectively, but had no effect on other species. Conclusion: This push-pull system offered modest protection against outdoor-biting An. arabiensis, without increasing indoor mosquito densities. Additional experimentation

  7. Light-induced heterogeneous reactions of NO2 on indoor surfaces: How they affect the balance of nitrous acid

    Science.gov (United States)

    Gomez Alvarez, E.; Soergel, M.; Bassil, S.; Zetzsch, C.; Gligorovski, S.; Wortham, H.

    2011-12-01

    Nitrous acid (HONO) is an important indoor pollutant. The adverse health effects due to the formation of nitrosamines are well known. HONO acts as a nitrosating agent after wall reactions of HONO with nicotine [Sleiman et al., 2010]. Indoor air can be surprisingly rich in HONO (homes with fireplaces, stoves, gas heating and cooking) and also surfaces are abundant. High HONO concentrations have been measured in indoor environments, from the direct emissions and heterogeneous reactions of NO2 in darkness. However, the measured HONO concentrations do not correspond to the HONO levels determined by the models [Carslaw, 2007]. We have tested in a flow tube reactor on-line coupled to a NOx analyzer and a sensitive Long Path Absorption Photometry instrument, the behaviour of various indoor surfaces towards NO2 under simulated solar light irradiation (λ= 300-700 nm). Our study has allowed us to obtain a deeper knowledge on the mechanisms of heterogeneous formation of HONO, quantifying the dependence of HONO formation on behalf of NO2 concentration and relative humidity and the enhancement of HONO formation in the presence of light. Pyrex, acidic detergent, alkaline detergent, paint and lacquer were tested on behalf of their heterogeneous reactivity towards NO2 in the absence and in presence of light. The results obtained demonstrated that indoor surfaces are photo-chemically active under atmospherically relevant conditions. The strongly alkaline surfaces (such as certain types of detergent) show a strong long-term uptake capacity. However, other surfaces such as detergents with a more acidic character released HONO. In some cases such as paint and varnish, a strong HONO release with light was detected, which was significantly higher than that obtained over clean glass surfaces. Certain organics present on their composition could exert a photo-sensitizing effect that may explain their increased reactivity. Unfortunately, the final balance points towards an important net

  8. Indoor Soiling Method and Outdoor Statistical Risk Analysis of Photovoltaic Power Plants

    Science.gov (United States)

    Rajasekar, Vidyashree

    This is a two-part thesis. Part 1 presents an approach for working towards the development of a standardized artificial soiling method for laminated photovoltaic (PV) cells or mini-modules. Construction of an artificial chamber to maintain controlled environmental conditions and components/chemicals used in artificial soil formulation is briefly explained. Both poly-Si mini-modules and a single cell mono-Si coupons were soiled and characterization tests such as I-V, reflectance and quantum efficiency (QE) were carried out on both soiled, and cleaned coupons. From the results obtained, poly-Si mini-modules proved to be a good measure of soil uniformity, as any non-uniformity present would not result in a smooth curve during I-V measurements. The challenges faced while executing reflectance and QE characterization tests on poly-Si due to smaller size cells was eliminated on the mono-Si coupons with large cells to obtain highly repeatable measurements. This study indicates that the reflectance measurements between 600-700 nm wavelengths can be used as a direct measure of soil density on the modules. Part 2 determines the most dominant failure modes of field aged PV modules using experimental data obtained in the field and statistical analysis, FMECA (Failure Mode, Effect, and Criticality Analysis). The failure and degradation modes of about 744 poly-Si glass/polymer frameless modules fielded for 18 years under the cold-dry climate of New York was evaluated. Defect chart, degradation rates (both string and module levels) and safety map were generated using the field measured data. A statistical reliability tool, FMECA that uses Risk Priority Number (RPN) is used to determine the dominant failure or degradation modes in the strings and modules by means of ranking and prioritizing the modes. This study on PV power plants considers all the failure and degradation modes from both safety and performance perspectives. The indoor and outdoor soiling studies were jointly

  9. Socioeconomic position and outdoor nitrogen dioxide (NO2) exposure in Western Europe : A multi-city analysis

    NARCIS (Netherlands)

    Temam, Sofia; Burte, Emilie; Adam, Martin; Antó, Josep M; Basagaña, Xavier; Bousquet, Jean; Carsin, Anne-Elie; Galobardes, Bruna; Keidel, Dirk; Künzli, Nino; Le Moual, Nicole; Sanchez, Margaux; Sunyer, Jordi; Bono, Roberto; Brunekreef, Bert; Heinrich, Joachim; de Hoogh, Kees; Jarvis, Debbie; Marcon, Alessandro; Modig, Lars; Nadif, Rachel; Nieuwenhuijsen, Mark; Pin, Isabelle; Siroux, Valérie; Stempfelet, Morgane; Tsai, Ming-Yi; Probst-Hensch, Nicole; Jacquemin, Bénédicte

    BACKGROUND: Inconsistent associations between socioeconomic position (SEP) and outdoor air pollution have been reported in Europe, but methodological differences prevent any direct between-study comparison. OBJECTIVES: Assess and compare the association between SEP and outdoor nitrogen dioxide (NO2)

  10. Coping with Indoor Air Pollution

    Science.gov (United States)

    ... Pollution > Coping with Indoor Air Pollution Font: Outdoor Pollution Indoor Air Pollution Asthma Triggers For Kids and Teachers Coping with Indoor Air Pollution Indoor air pollution is irritating to everyone: But people who ...

  11. Long-term exposure to indoor air pollution and wheezing symptoms in infants

    DEFF Research Database (Denmark)

    Raaschou-Nielsen, O.; Hermansen, M.N.; Loland, L.

    2010-01-01

    Long-term exposure to air pollution is suspected to cause recurrent wheeze in infants. The few previous studies have had ambiguous results. The objective of this study was to estimate the impact of measured long-term exposure to indoor air pollution on wheezing symptoms in infants. We monitored......-point 'any symptom-day' (yes/no) and by standard linear regression with the end-point 'number of symptom-days'. The results showed no systematic association between risk for wheezing symptoms and the levels of these air pollutants with various indoor and outdoor sources. In conclusion, we found no evidence...... of an association between long-term exposure to indoor air pollution and wheezing symptoms in infants, suggesting that indoor air pollution is not causally related to the underlying disease. Practical Implications Nitrogen oxides, formaldehyde and fine particles were measured in the air in infants' bedrooms...

  12. Measurement of dose-determining physical parameters (F-factor, fp factor,...) for comparative analysis of outdoor/indoor radon exposure

    International Nuclear Information System (INIS)

    Anon

    1998-01-01

    The purpose of the project was to measure the airborne natural radon activity concentrations outdoor and the dose-determining parameters [non-deposited fraction (f p ), radon daughter products (F, PAEC), as well as the radioactive aerosol size distribution]. The impacts of meteorological parameters (pressure, rainfalls, wind velocities and temperature) on the those parameters and the exhalation of radon from the soil were to be determined. The acquired information was to be applied for an evaluation of the radiological outdoor situation and subsequent comparative analysis with the indoor radon exposure. (orig./CB) [de

  13. Thermal (dis)comfort experienced from physiological movements across indoor, transitional and outdoor spaces in Singapore: A pilot study

    Science.gov (United States)

    Li Heng, Su; Chow, Winston

    2017-04-01

    WBGT, and that participants often were at "high" risk of heat stress from pedestrian movement; (b.) participants were most comfortable with humidity sensations across all spaces compared to other microclimate sensations (e.g. wind, heat, sun); (c.) correlation between microclimate sensation and WBGT varied across participants and across spaces, with stronger correlation between sun sensation votes and WBGT for most participants, and (d.) heart rates of individuals were not significant in estimating and predicting PET for activities such as pedestrian walking. Present results confirm that WBGT applies better to hot climates and outdoor thermal comfort, but not so for hot, humid climates and indoor thermal comfort. Self-reported (subjective) thermal comfort also differed from measured (objective) thermal comfort and across participants because acclimatized individuals can have different sensitivities and acceptance towards (dis)comfort arising from pedestrian movement across spaces. Finally, we suggest that future pedestrian thermal comfort studies employ longitudinal studies and traverse measurements to consider the critical aspects of thermal history and individual sensitivities to on (dis)comfort levels.

  14. The effect of the indoor environment on the fate of organic chemicals in the urban landscape

    International Nuclear Information System (INIS)

    Cousins, Anna Palm

    2012-01-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical–chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK OA and the impact of the ventilation rate on the urban fate of organic chemicals. -- Highlights: ► A novel indoor-inclusive multimedia urban fate model is developed and applied. ► Emissions indoors may increase the urban chemical residence time. ► Indoor removal from surfaces constitutes an additional loss process

  15. Assessment of indoor environment in Paris child day care centers.

    Science.gov (United States)

    Roda, Célina; Barral, Sophie; Ravelomanantsoa, Hanitriniala; Dusséaux, Murielle; Tribout, Martin; Le Moullec, Yvon; Momas, Isabelle

    2011-11-01

    Children are sensitive to indoor environmental pollution. Up until now there has been a lack of data on air quality in child day care centers. The aim of this study is to document the indoor environment quality of Paris child day care centers by repeated measurements, and to compare pollutant levels in child day care centers with levels in Paris dwellings. We selected 28 child day care centers frequented by a random sample of babies who participated in the PARIS birth cohort environmental investigation, and visited the child day care centers for one week twice in one year. Biological contaminants assessed were fungi, endotoxin, dust mite allergens, and chemical pollutants: aldehydes, volatile organic compounds and nitrogen dioxide (NO2). Relative humidity, temperature, and carbon dioxide levels were measured simultaneously. A standardized questionnaire was used to gather information about the buildings and their inhabitants. Airborne endotoxin levels in child day care centers were higher than those found in Paris dwellings. Dust mite allergens in child day care centers were below the threshold level for sensitization in the majority of samples, and in common with dwelling samples. Penicillium and Cladosporium were the most commonly identified genera fungi. The child day care center indoor/outdoor ratio for most chemical pollutants was above unity except for NO2, the levels for NO2 being significantly higher than those measured in homes. Chemical and biological contamination in child day care centers appears to be low, apart from endotoxin and NO2. Failure to take child exposure in child day care centers into account could result in an overestimation of children's exposure to other pollutants. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Indoor radon and its progeny levels in new type houses in rural area of Hubei

    International Nuclear Information System (INIS)

    He Quan; Xiong Zhaoxing; He Zuan; Zheng Youqing

    1993-01-01

    Using Cluster Sampling method, indoor radon of 54 rooms and radon progeny potential alpha-energy concentrations of 200 rooms were measured in the new type brick-concrete 2-storey flats and old type brick-wood single-storey residences in the rural area. Instant and cumulative samplings and measurements were made. The average per capita residential area of the surveyed houses was 28.1 m 2 , clear height 3.6 m. The geometric means of indoor radon concentration were 18.22 Bq.m -3 and 15.93 Bq.m -3 for storied and single-storey buildings, respectively; radon progeny potential alpha-energy concentrations were 2.62 mWL and 2.54 mWL, correspondingly. In storied buildings, the arithmetic mean of indoor cumulative radon concentration was 25.56 Bq.m -3 in summer, and 37.94 Bq.m -3 in winter. The annual effective dose equivalent of radon progeny inhaled indoors and outdoors was 0.80 mSv. (orig.). (6 refs., 1 fig., 5 tabs.)

  17. Seasonal fate and gas/particle partitioning of semi-volatile organic compounds in indoor and outdoor air

    Science.gov (United States)

    Moreau-Guigon, Elodie; Alliot, Fabrice; Gaspéri, Johnny; Blanchard, Martine; Teil, Marie-Jeanne; Mandin, Corinne; Chevreuil, Marc

    2016-12-01

    Fifty-eight semi-volatile organic compounds (SVOCs) were investigated simultaneously in three indoor (apartment, nursery and office building) and one outdoor environment in the centre of Paris (France). All of these compounds except tetrabromobisphenol A were quantified in the gaseous and particulate phases in all three environments, and at a frequency of 100% for the predominant compounds of each SVOC class. Phthalic acid esters (PAEs) were the most abundant group (di-iso-butyl phthalate: 29-661 ng m-3, diethyl phthalate: 15-542 ng m-3), followed by 4-nonylphenol (1.4-81 ng m-3), parabens (methylparaben: 0.03-2.5 ng m-3), hexachlorobenzene (HCB) (0.002-0.26 ng m-3) and pentachlorobenzene (PeCB) (0.001-0.23 ng m-3). Polycyclic aromatic hydrocarbons (as ∑8PAHs) ranged from 0.17 to 5.40 ng m-3, polychlorinated biphenyls (as ∑7PCBi) from 0.06 to 4.70 ng.m3 and polybromodiphenyl ethers (as ∑8PBDEs) from 0.002 to 0.40 ng m-3. For most pollutants, significantly higher concentrations were observed in the nursery compared to the apartment and office. Overall, the indoor air concentrations were up to ten times higher than outdoor air concentrations. Seasonal variations were observed for PAEs, PCBs and PAHs. SVOCs were predominantly identified in the gaseous phase (>90%), except for some high-molecular-weight PAEs, PAHs and PCBs.

  18. Effect of ventilation rate on concentrations of indoor radon and its progenies

    International Nuclear Information System (INIS)

    Wang Chunhong; Liu Yanyang; Liu Fudong; Liu Senlin; Chen Ling

    2012-01-01

    To study concentrations of indoor radon and its progenies, ventilation rates and their corresponding concentrations of indoor radon and its progenies were measured using tracer-gas dilution method. Results show that both ventilation rates and concentrations of indoor radon varied insignificantly and radon concentration were higher than the outdoor environment while doors and windows were all closed with air-conditioner on and off respectively; the concentrations declined and close to the outdoor level when doors and windows were all open with ventilators in operation. Accordingly, in modern life, especially in summer, people's preference for air-conditioners but natural ventilation would result in an increase of indoor radon concentration. (authors)

  19. Vitality of plants to live in the indoor environment

    Science.gov (United States)

    Shamsuri, Mohd Mahathir Suhaimi; Leman, A. M.; Hariri, Azian; Idris, Ahmad Fu'ad; Afandi, Azizi

    2017-09-01

    Indoor air quality (IAQ) is generally a public concern because 90% of people spend their time indoor. IAQ must be preserved wisely to guarantee the health of the building occupants. One of the ways to maintain the quality of air is by placing plants in the building. However, all plants come from the outdoor, and the environment is different compared to indoor. Environmental factors such as temperature and light will absolutely affect the growth of the plant. Light and temperature that are too bright or too deem can wither the plants. Nevertheless, certain plant is capable of adapting with different situation after assimilation process has been conducted. This study intends to analyze the capacity of seven selected plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium) to live in an indoor environment. The vitality of plants is based on photosynthetic level that is measured using leaf - chamber (LI-COR 6400). Two groups of plants were located in indoor and outdoor (indigenous location) setting, and were allowed to assimilate for two months before measurement were carried out. The results for the plant located indoor shows that only Spider Plant cannot perform photosynthesis under 300 lux, where the photosynthetic value remains negative. Meanwhile, other plants such as Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, and Syngonium that were left indoor showed similar 300 lux in which conform the ability of the plants to perform photosynthesis with the value of 0.3, 0.15, 0.35, 0.1, 0.15, and 0.1. In comparison, all of the plants that were stationed indoor and outdoor (except Spider Plant), the light compensation point (LCP) for indoor shows smaller value than the outdoor. This is because all the indoor plants had down - regulated their photosynthesis process by becoming more sensitive to light after their assimilation. From this study, it can be concluded that all plants except Spider Plant is able to live

  20. Indoor PAHs at schools, homes and offices in Rome, Italy

    Science.gov (United States)

    Romagnoli, P.; Balducci, C.; Perilli, M.; Gherardi, M.; Gordiani, A.; Gariazzo, C.; Gatto, M. P.; Cecinato, A.

    2014-08-01

    Indoor and outdoor concentrations of polycyclic aromatic hydrocarbons (PAHs) associated with PM2.5 particles were monitored in three microenvironments (schools, homes and offices) in the city of Rome, Italy, between winter 2011 and summer 2012. Molecular signatures and indoor/outdoor concentration ratios of PAHs were investigated, with special emphasis on carcinogenic congeners. At indoor locations, total PAHs ranged, on average, from 1.8 to 8.4 ng/m3 in winter and from 0.30 to 1.35 ng/m3 in spring/summer. Outdoors, total PAH concentrations were found to reach 6.3-17.9 ng/m3 in winter and 0.42-1.74 ng/m3 in spring-summer. Indoors, the concentration of benzo[a]pyrene (BaP) was as high as 1.1 ng/m3 in winter and below 0.1 ng/m3 in the warm season, independently of site type; the yearly average remained below the European guideline value. The indoor/outdoor concentration ratios of individual compounds were lower than one for most of congeners, suggesting that outdoor sources were predominant. Nonetheless, the percentages of PAH compounds changed with sites and seasons; in particular, in spring/summer, the concentration of BaP at our sites was more than twice that recorded at the regional network stations.

  1. Hourly indoor radon measurements in a research house.

    Science.gov (United States)

    Sesana, Lucia; Begnini, Stefania

    2004-01-01

    This paper reports and discusses the behaviour of radon concentration with time in an uninhabited dwelling. The relationship between variations in radon concentrations and indoor-outdoor temperatures and wind intensity has also been discussed. Radon concentration was measured hourly in a house located at a height of 800 m in the Lombard Prealps, at the top of the Valassina valley. The wind velocity and indoor-outdoor temperatures were measured by means of a meteorological station located on the terrace of the house. The data were analysed using the LBL model for indoor-outdoor air exchange and the models for the indoor accumulation of radon due to exhalation from building materials and pressure-driven infiltrations located underground. The role of wind and indoor-outdoor temperatures were analysed. The agreement of measurements with modelling clearly demonstrates the importance of the different sources of indoor radon. As the investigation was conducted in an uninhabited house, the measurements were not affected by the behaviour of people, e.g. opening and closing of windows. Measurements of the outdoor atmospheric concentrations of (222)Rn provide an index of the atmospheric stability, the formation of thermal inversions and convective turbulence.

  2. Hourly indoor radon measurements in a research house

    International Nuclear Information System (INIS)

    Sesana, L.; Begnini, S.

    2004-01-01

    This paper reports and discusses the behaviour of radon concentration with time in an uninhabited dwelling. The relationship between variations in radon concentrations and indoor-outdoor temperatures and wind intensity has also been discussed. Radon concentration was measured hourly in a house located at a height of 800 m in the Lombard Pre-alps, at the top of the Valassina valley. The wind velocity and indoor-outdoor temperatures were measured by means of a meteorological station located on the terrace of the house. The data were analysed using the LBL model for indoor-outdoor air exchange and the models for the indoor accumulation of radon due to exhalation from building materials and pressure-driven infiltrations located underground. The role of wind and indoor-outdoor temperatures were analysed. The agreement of measurements with modelling clearly demonstrates the importance of the different sources of indoor radon. As the investigation was conducted in an uninhabited house, the measurements were not affected by the behaviour of people, e.g. opening and closing of windows. Measurements of the outdoor atmospheric concentrations of 222 Rn provide an index of the atmospheric stability, the formation of thermal inversions and convective turbulence. (authors)

  3. Indoor Tanning

    Science.gov (United States)

    ... proof that indoor tanning is safer than tanning outdoors. Indoor tanning systems give concentrated UV exposure regardless ... For example, it’s essential for promoting good bone health. While UV ... a tan to get that benefit. According to the Surgeon General, fair and light- ...

  4. Community perceptions on outdoor malaria transmission in Kilombero Valley, Southern Tanzania.

    Science.gov (United States)

    Moshi, Irene R; Ngowo, Halfan; Dillip, Angel; Msellemu, Daniel; Madumla, Edith P; Okumu, Fredros O; Coetzee, Maureen; Mnyone, Ladslaus L; Manderson, Lenore

    2017-07-04

    The extensive use of indoor residual spraying (IRS) and insecticide-treated nets (ITNs) in Africa has contributed to a significant reduction in malaria transmission. Even so, residual malaria transmission persists in many regions, partly driven by mosquitoes that bite people outdoors. In areas where Anopheles gambiae s.s. is a dominant vector, most interventions target the reduction of indoor transmission. The increased use of ITNs/LLINs and IRS has led to the decline of this species. As a result, less dominant vectors such as Anopheles funestus and Anopheles arabiensis, both also originally indoor vectors but are increasingly biting outdoors, contribute more to residual malaria transmission. The study reports the investigated community perceptions on malaria and their implications of this for ongoing outdoor malaria transmission and malaria control efforts. This was a qualitative study conducted in two rural villages and two peri-urban areas located in Kilombero Valley in south-eastern Tanzania. 40 semi-structured in-depth interviews and 8 focus group discussions were conducted with men and women who had children under the age of five. The Interviews and discussions focused on (1) community knowledge of malaria transmission, and (2) the role of such knowledge on outdoor malaria transmission as a contributing factor to residual malaria transmission. The use of bed nets for malaria prevention has been stressed in a number of campaigns and malaria prevention programmes. Most people interviewed believe that there is outdoor malaria transmission since they use interventions while indoors, but they are unaware of changing mosquito host-seeking behaviour. Participants pointed out that they were frequently bitten by mosquitoes during the evening when outdoors, compared to when they were indoors. Most participants stay outdoors in the early evening to undertake domestic tasks that cannot be conducted indoors. House structure, poor ventilation and warm weather conditions

  5. Research trends in outdoor pig production — A review

    Directory of Open Access Journals (Sweden)

    Hyun-Suk Park

    2017-09-01

    Full Text Available Since the industrialization of swine production in the late 1900s, swine farms in the United States, as well as in Europe, have largely become consolidated. Pig farms became larger in size but fewer in number, with 91% of market pigs being produced by large operations with 5,000 or more pigs on-site in the US, and only 3% of the total utilized agricultural land representing organic farming. Such change in the market made it difficult for small farmers to stay competitive, forcing them to find alternative ways to reduce the cost of production and increase profit using the outdoor production system. In contrast to the indoor confinement system, outdoor production system uses pasture-based units and/or deep-bedded hoop structures that promote animal welfare and environmental sustainability with a lower capital investment. In accord with the growing concern for animal and environmental welfare and food safety by the consumers, small farmers practicing an outdoor production system are seeing increased opportunities for marketing their products in the pork niche market. Unlike the general belief that the reproductive and growth performance measures of the outdoor sows and piglets are poorer in comparison with the animals reared indoors, studies showed that there was no significant difference in the performance measures, and some traits were even better in outdoor animals. Improved reproductive and production traits can increase the sustainability of outdoor farming. Present study reviewed the recent studies comparing the performance measures, meat quality and health of indoor and outdoor animals, as well as the efforts to improve the outdoor production system through changes in management such as hut types and breed of animals.

  6. Research trends in outdoor pig production — A review

    Science.gov (United States)

    Park, Hyun-Suk; Min, Byungrok; Oh, Sang-Hyon

    2017-01-01

    Since the industrialization of swine production in the late 1900s, swine farms in the United States, as well as in Europe, have largely become consolidated. Pig farms became larger in size but fewer in number, with 91% of market pigs being produced by large operations with 5,000 or more pigs on-site in the US, and only 3% of the total utilized agricultural land representing organic farming. Such change in the market made it difficult for small farmers to stay competitive, forcing them to find alternative ways to reduce the cost of production and increase profit using the outdoor production system. In contrast to the indoor confinement system, outdoor production system uses pasture-based units and/or deep-bedded hoop structures that promote animal welfare and environmental sustainability with a lower capital investment. In accord with the growing concern for animal and environmental welfare and food safety by the consumers, small farmers practicing an outdoor production system are seeing increased opportunities for marketing their products in the pork niche market. Unlike the general belief that the reproductive and growth performance measures of the outdoor sows and piglets are poorer in comparison with the animals reared indoors, studies showed that there was no significant difference in the performance measures, and some traits were even better in outdoor animals. Improved reproductive and production traits can increase the sustainability of outdoor farming. Present study reviewed the recent studies comparing the performance measures, meat quality and health of indoor and outdoor animals, as well as the efforts to improve the outdoor production system through changes in management such as hut types and breed of animals. PMID:28728401

  7. Relationship between indoor radon concentrations and air exchange rate

    International Nuclear Information System (INIS)

    Wang Jingshu; Liu Yuyu; Yao Xiaohua; Meng Jianfeng; Zhang Yongyi; Wang Xiaohe; Yu Xiufen.

    1995-01-01

    The indoor concentration of radon and the air exchange rate were simultaneously measured in four empty rooms, made of brick and cement, which were located in different floors of dwelling houses in Taiyuan, Shanxi, China. SF 6 tracer gas decay method was used to measure the air exchange rate. Indoor radon was collected with the dimembrane method. When the ventilation rate increased, the concentration of radon dropped rapidly. Regression analysis indicated that the indoor concentration of radon was equal to the outdoor level of radon when the air exchange rate was greater than 3-4. SF 6 decay method was an effective and convenient method for measuring the air exchange rate. There was no marked difference in measurements obtained in different locations of a room. (N.K.)

  8. The effect of the indoor environment on the fate of organic chemicals in the urban landscape

    Energy Technology Data Exchange (ETDEWEB)

    Cousins, Anna Palm, E-mail: anna.cousins@ivl.se

    2012-11-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical-chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK{sub OA} and the impact of the ventilation rate on the urban fate of organic chemicals. -- Highlights: Black-Right-Pointing-Pointer A novel indoor-inclusive multimedia urban fate model is developed and applied. Black-Right-Pointing-Pointer Emissions indoors may increase the urban chemical residence time. Black

  9. Indoor randon concentration. Temperature and wind effects; Concentrazione di radon indoor. Effetto del vento e della temperatura

    Energy Technology Data Exchange (ETDEWEB)

    Sesana, L.; Benigni, S. [Milan Univ., Milan (Italy). Ist. di Fisica Generale Applicata

    2000-12-01

    The present study analyses and discusses the behaviour of the indoor radon concentration in a research house. Hourly measurements were carried out in the basement of the house from November 1998 up to June 1999. In many sequences of days radon concentration in the room under analysis shows strong variation all day long with accumulation in the evening and overnight and decrease in the morning and in the afternoon. Measurements of wind velocity, indoor and outdoor temperatures and outdoor-indoor pressure difference were performed and their trend is compared with the observed radon concentration. The exhalation of radon from walls, floor and ceiling and the pressure difference driven exhalation from the soil are discussed, particularly the relation with the temperature differences. The air exchange rates between the house and the outdoor air are studied. [Italian] Si analizza e si discute il comportamento della concentrazione di radon indoor nel seminterrato di una casa di ricerca. Misure orarie sono state effettuate da novembre 1998 a giugno 1999. In molte sequenze di giorni la concentrazione del radon nel locale in analisi presenta forti variazioni nel corso della giornata con un accumulo notturno e decrescita nelle ore diurne. Sono state eseguite misure della velocita' del vento, delle temperature outdoor e indoor e della differenza di pressione outdoor-indoor e il loro andamento e' stato confrontato con quello della concentrazione del radon. Vengono discusse l'esalazione del radon dalle pareti, dal pavimento e dal soffitto e l'esalazione pressure difference driven dal suolo. Il rateo dei ricambi d'aria tra il locale e l'aria outdoor e' studiato.

  10. Is outdoor vector control needed for malaria elimination? An individual-based modelling study.

    Science.gov (United States)

    Zhu, Lin; Müller, Günter C; Marshall, John M; Arheart, Kristopher L; Qualls, Whitney A; Hlaing, WayWay M; Schlein, Yosef; Traore, Sekou F; Doumbia, Seydou; Beier, John C

    2017-07-03

    combinational intervention of 50% LLINs plus outdoor ATSBs significantly reduced mosquito population in short term, increased the probability of mosquito extinction, and increased the time when annual EIR is less than one per person compared to 50% LLINs alone; outdoor ATSBs alone significantly reduced mosquito population in short term, but there were no significant difference in the probability of mosquito extinction and the time when annual EIR is less than one between 50% LLIN and outdoor ATSBs; and there was no significant difference in EIR between all three interventions. A minimum of 2 months of efficacy period is needed to bring out the best possible effect of the vector control tools, and to achieve long-term mosquito reduction, a minimum of 3 months of efficacy period is needed. The results highlight the value of incorporating outdoor vector control into IVM as a supplement to traditional indoor practices for malaria elimination in Africa, especially in village settings of clustered houses where LLINs alone is far from sufficient.

  11. BlueDetect: An iBeacon-Enabled Scheme for Accurate and Energy-Efficient Indoor-Outdoor Detection and Seamless Location-Based Service.

    Science.gov (United States)

    Zou, Han; Jiang, Hao; Luo, Yiwen; Zhu, Jianjie; Lu, Xiaoxuan; Xie, Lihua

    2016-02-22

    The location and contextual status (indoor or outdoor) is fundamental and critical information for upper-layer applications, such as activity recognition and location-based services (LBS) for individuals. In addition, optimizations of building management systems (BMS), such as the pre-cooling or heating process of the air-conditioning system according to the human traffic entering or exiting a building, can utilize the information, as well. The emerging mobile devices, which are equipped with various sensors, become a feasible and flexible platform to perform indoor-outdoor (IO) detection. However, power-hungry sensors, such as GPS and WiFi, should be used with caution due to the constrained battery storage on mobile device. We propose BlueDetect: an accurate, fast response and energy-efficient scheme for IO detection and seamless LBS running on the mobile device based on the emerging low-power iBeacon technology. By leveraging the on-broad Bluetooth module and our proposed algorithms, BlueDetect provides a precise IO detection service that can turn on/off on-board power-hungry sensors smartly and automatically, optimize their performances and reduce the power consumption of mobile devices simultaneously. Moreover, seamless positioning and navigation services can be realized by it, especially in a semi-outdoor environment, which cannot be achieved by GPS or an indoor positioning system (IPS) easily. We prototype BlueDetect on Android mobile devices and evaluate its performance comprehensively. The experimental results have validated the superiority of BlueDetect in terms of IO detection accuracy, localization accuracy and energy consumption.

  12. BlueDetect: An iBeacon-Enabled Scheme for Accurate and Energy-Efficient Indoor-Outdoor Detection and Seamless Location-Based Service

    Directory of Open Access Journals (Sweden)

    Han Zou

    2016-02-01

    Full Text Available The location and contextual status (indoor or outdoor is fundamental and critical information for upper-layer applications, such as activity recognition and location-based services (LBS for individuals. In addition, optimizations of building management systems (BMS, such as the pre-cooling or heating process of the air-conditioning system according to the human traffic entering or exiting a building, can utilize the information, as well. The emerging mobile devices, which are equipped with various sensors, become a feasible and flexible platform to perform indoor-outdoor (IO detection. However, power-hungry sensors, such as GPS and WiFi, should be used with caution due to the constrained battery storage on mobile device. We propose BlueDetect: an accurate, fast response and energy-efficient scheme for IO detection and seamless LBS running on the mobile device based on the emerging low-power iBeacon technology. By leveraging the on-broad Bluetooth module and our proposed algorithms, BlueDetect provides a precise IO detection service that can turn on/off on-board power-hungry sensors smartly and automatically, optimize their performances and reduce the power consumption of mobile devices simultaneously. Moreover, seamless positioning and navigation services can be realized by it, especially in a semi-outdoor environment, which cannot be achieved by GPS or an indoor positioning system (IPS easily. We prototype BlueDetect on Android mobile devices and evaluate its performance comprehensively. The experimental results have validated the superiority of BlueDetect in terms of IO detection accuracy, localization accuracy and energy consumption.

  13. Effect of outdoor and indoor air pollution on lung function, bronchial hyperresponsiveness and risk of pulmonary disease of adults; Langzeitevaluation von Umwelteinfluessen auf Lungenfunktion, bronchiale Hyperreagibilitaet und Krankheitsrisiko von Erwachsenen

    Energy Technology Data Exchange (ETDEWEB)

    Eltschka, R [Freiburg Univ. (Germany). Zentrum Innere Medizin

    1992-10-01

    The effect of outdoor exposure to SO{sub 2}, NO{sub 2}, particulate pollutants, ozone and pollen on pulmonary function and respiratory discomfort was studied over a period of 1 1/2 yr in 133 no smoking adults at the city of Freiburg. Concentration of indoor and outdoor pollutants were measured. Between January and December 1989 we found in comparison with other large towns low levels of SO{sub 2}, NO{sub 2} and particulate combustion products. The evaluation of individual exposure to air pollutants with lung function measurements shows that participants with essential hyperreactivity demonstrate a significant decrease of the FEV1/IVC - ratio with a threshold value of about 30 {mu}g/m{sup 3} NO{sub 2}. The analyses of the longitudinal study shows a significant correlation between daily peakflow measurements and ozone levels in patients with symptomatic asthma bronchiale and chronic obstructive pulmonary disease. For pollen, SO{sub 2}, NO{sub 2} and anorganic particulate pollutants we did not find any significant effects on peak expiratory flow measurements. (orig./MG) [Deutsch] Der Einfluss von Aussenluftschadstoffen (SO{sub 2}, NO{sub 2}, Staub und Ozon) auf die Lunge wurde in Freiburg in Form einer 1 1/2-jaehrigen Longitudinalstudie bei 133 nicht rauchenden Erwachsenen untersucht. Waehrend des Beobachtungszeitraumes 10/88 - 4/90 erfolgte die Messung der Aussen- und Innenluftschadstoffe. Die Messungen des DW und der LFU zeigen fuer den Zeitraum Januar-Dezember 1989 im Vergleich zu anderen Grossstaedten niedrige Schwefeldioxid-, Stickoxid- und Staubkonzentrationen. Die Querschnittsuntersuchung mit Anamnesefragebogen, Bodyplethysmographie und inhalativem Provokationstest zeigt bei Teilnehmern mit essentieller Hyperreagibilitaet eine signifikante Abnahme des gemessenen und adjustierten Tiffeneau-Index durch NO{sub 2} mit einem Schwellenwert bei 30 {mu}g/m{sup 3}. Die multivariate Analyse der Longitudinalstudie zeigt bei Patienten mit symptomatischem Asthma und

  14. Indoor wayfinding and navigation

    CERN Document Server

    2015-01-01

    Due to the widespread use of navigation systems for wayfinding and navigation in the outdoors, researchers have devoted their efforts in recent years to designing navigation systems that can be used indoors. This book is a comprehensive guide to designing and building indoor wayfinding and navigation systems. It covers all types of feasible sensors (for example, Wi-Fi, A-GPS), discussing the level of accuracy, the types of map data needed, the data sources, and the techniques for providing routes and directions within structures.

  15. Indoor climate and air quality . Review of current and future topics in the field of ISB study group 10

    Science.gov (United States)

    Höppe, P.; Martinac, Ivo

    In industrialized countries about 90% of the time is spent indoors. The ambient parameters affecting indoor thermal comfort are air temperature and humidity, air velocity, and radiant heat exchange within an enclosure. In assessing the thermal environment, one needs to consider all ambient parameters, the insulating properties of the occupants' clothing, and the activity level of the occupants by means of heat balance models of the human body. Apart from thermal parameters, air quality (measured and perceived) is also of importance for well-being and health in indoor environments. Pollutant levels are influenced by both outdoor concentrations and by indoor emissions. Indoor levels can thus be lower (e.g. in the case of ozone and SO2) or higher (e.g. for CO2 and formaldehyde) than outdoor levels. Emissions from cooking play an important role, especially in developing countries. The humidity of the ambient air has a wide range of effects on the energy and water balance of the body as well as on elasticity, air quality perception, build-up of electrostatic charge and the formation or mould. However, its effect on the indoor climate is often overestimated. While air-handling systems are commonly used for achieving comfortable indoor climates, their use has also been linked to a variety of problems, some of which have received attention within the context of ''sick building syndrome''.

  16. Indoor air pollution: a public health perspective

    International Nuclear Information System (INIS)

    Spengler, J.D.; Sexton, K.

    1983-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms, and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  17. Risk of HIV infection among indoor and street sex workers and their use of health services in Belgrade, Serbia.

    Science.gov (United States)

    Ilić, Dragan; Sipetić, Sandra; Bjegović, Vesna

    2010-01-01

    HIV in Serbia is most often transmitted through sexual contact, and therefore numerous prevention activities are geared towards sex workers (SW). To analyse the differences in knowledge, attitudes and risky behaviour between indoor and street SW in Belgrade; to examine the accessibility of health services to this vulnerable group. In this behavioural cross-sectional study, 113 street and 78 indoor SW were included. The sampling method used was snowball samples. Data were gathered through structured questionnaires. Around 15% of respondents used drugs intravenously. Around 60% of SW used a condom during the last sexual intercourse with their private partner, and around 90% with a commercial partner. Indoor SW had lower levels of education more often than outdoor SW, and they used marijuana, sedatives and painkillers on a daily basis. A significantly higher number of indoor SW were informed about HIV, HBV and HCV testing, and that the risk for HIV infection is not lower ifa condom is used exclusively for vaginal sex. Indoor SW reported using health services and testing and counselling for HIV, HBV and HCV more frequently than outdoor SW. Outdoor SW had significantly more sex partners in the previous month than indoor SW. Indoor SW recognized more frequently that providing sex services posed a higher risk for HIV infection. The results of this research study show that even though outdoor SW had higher levels of education than indoor SW, their level of knowledge about HIV transmission was lower and they reported more risky behaviour than indoor SW. Data show that both groups reported not taking care of their health.

  18. Safety assessment of outdoor live fire range

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1989-05-01

    The following Safety Assessment (SA) pertains to the outdoor live fire range facility (LFR). The purpose of this facility is to supplement the indoor LFR. In particular it provides capacity for exercises that would be inappropriate on the indoor range. This SA examines the risks that are attendant to the training on the outdoor LFR. The outdoor LFR used by EG&G Mound is privately owned. It is identified as the Miami Valley Shooting Grounds. Mondays are leased for the exclusive use of EG&G Mound.

  19. Standards for securing adequate indoor air quality across Europe

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Carrer, P.; de Oliveira Fernandes, E.

    2013-01-01

    Background: Inadequate IAQ causes a loss of 2 million healthy life years annually in the EU. Europeans spend typically over 85–90% of their time indoors and the main factors that affect negatively the characteristics of the air they breathe are outdoor air used to ventilate indoor spaces and indoor...... effects of IAQ into different components: exposures to indoor and outdoor air pollutants, association with different morbidities and the way ventilation based approaches could minimise their impact. Disability adjusted life years (DALYs), a common metric to allow comparability of impacts on various types...... and is determined mainly considering the metabolic CO2 production. It is only applicable if all other pollutants meet WHO guidelines for ambient and indoor air quality. If they do not meet these guidelines after applying source control and when air used for ventilation is clean health-based ventilation rate should...

  20. Ventilation influence upon indoor air radon level

    International Nuclear Information System (INIS)

    Tian Deyuan

    1995-01-01

    Levels of indoor radon in air are studied by a continuous electrostatic radon monitor under normal living conditions to evaluate the influence of air conditioned ventilation on indoor air radon level. Results show that the indoor air radon concentrations are not much more than those without household conditioner living condition, although using household conditioner requires a sealed room which should lead to a higher radon level. Turning on air conditioner helps lower indoor radon level. Therefore, the total indoor air Rn levels are normal > ventilation > exhaust or in-draft > exhaust plus in-draft

  1. Airborne particles in indoor environment of homes, schools, offices and aged care facilities: The main routes of exposure.

    Science.gov (United States)

    Morawska, L; Ayoko, G A; Bae, G N; Buonanno, G; Chao, C Y H; Clifford, S; Fu, S C; Hänninen, O; He, C; Isaxon, C; Mazaheri, M; Salthammer, T; Waring, M S; Wierzbicka, A

    2017-11-01

    It has been shown that the exposure to airborne particulate matter is one of the most significant environmental risks people face. Since indoor environment is where people spend the majority of time, in order to protect against this risk, the origin of the particles needs to be understood: do they come from indoor, outdoor sources or both? Further, this question needs to be answered separately for each of the PM mass/number size fractions, as they originate from different sources. Numerous studies have been conducted for specific indoor environments or under specific setting. Here our aim was to go beyond the specifics of individual studies, and to explore, based on pooled data from the literature, whether there are generalizable trends in routes of exposure at homes, schools and day cares, offices and aged care facilities. To do this, we quantified the overall 24h and occupancy weighted means of PM 10 , PM 2.5 and PN - particle number concentration. Based on this, we developed a summary of the indoor versus outdoor origin of indoor particles and compared the means to the WHO guidelines (for PM 10 and PM 2.5 ) and to the typical levels reported for urban environments (PN). We showed that the main origins of particle metrics differ from one type of indoor environment to another. For homes, outdoor air is the main origin of PM 10 and PM 2.5 but PN originate from indoor sources; for schools and day cares, outdoor air is the source of PN while PM 10 and PM 2.5 have indoor sources; and for offices, outdoor air is the source of all three particle size fractions. While each individual building is different, leading to differences in exposure and ideally necessitating its own assessment (which is very rarely done), our findings point to the existence of generalizable trends for the main types of indoor environments where people spend time, and therefore to the type of prevention measures which need to be considered in general for these environments. Copyright © 2017 The

  2. Indoor air quality in preschools (3- to 5-year-old children) in the Northeast of Portugal during spring-summer season: pollutants and comfort parameters.

    Science.gov (United States)

    Oliveira, Marta; Slezakova, Klara; Delerue-Matos, Cristina; Pereira, Maria do Carmo; Morais, Simone

    2017-01-01

    Indoor air quality at schools (elementary, primary) has been the subject of many studies; however, there are still relative few data regarding preschool (3- to 5-year-old children) environments. This investigation determined the concentrations of particulate matter (PM) 2.5 , total volatile organic compounds (TVOC), formaldehyde, carbon monoxide (CO), and ozone (O 3 ) as well as the levels of carbon dioxide (CO 2 ), temperature, and relative humidity (RH) in the indoor and outdoor air of two preschools situated in different geographical regions of Portugal. The indoor concentrations of TVOC, CO, O 3 , and CO 2 were predominantly higher at the end of school day compared to early morning periods. The TVOC and CO 2 concentrations were higher indoors than outdoors suggesting predominantly an indoor origin. Outdoor air infiltrations were the major contributing source of CO and O 3 to indoor air in both preschools. The concentrations of all pollutants were within the limits defined by national regulations and international organizations, except for TVOC that exceeded 8-12-fold higher than the recommendation of 0.2 mg/m 3 proposed by European Commission. The levels of CO 2 were below the protective guideline of 2250 mg/m 3 (Portuguese legislation); however, the observed ranges exceeded the Portuguese margin of tolerance (2925 mg/m 3 ) at the end of school days, indicating the impact of occupancy rates particularly at one of the preschools. Regarding comfort parameters, temperature exerted a significant influence on O 3 concentrations, while RH values were significantly correlated with TVOC levels in indoor air of preschools, particularly during the late afternoon periods.

  3. Current implications of past DDT indoor spraying in Oman.

    Science.gov (United States)

    Booij, Petra; Holoubek, Ivan; Klánová, Jana; Kohoutek, Jiří; Dvorská, Alice; Magulová, Katarína; Al-Zadjali, Said; Čupr, Pavel

    2016-04-15

    In Oman, DDT was sprayed indoors during an intensive malaria eradication program between 1976 and 1992. DDT can remain for years after spraying and is associated with potential health risk. This raises the concern for human exposure in areas where DDT was used for indoor spraying. Twelve houses in three regions with a different history of DDT indoor spraying were chosen for a sampling campaign in 2005 to determine p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT), p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) and p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) levels in indoor air, dust, and outdoor soil. Although DDT was only sprayed indoor, p,p'-DDT, p,p'-DDE and p,p'-DDD were also found in outdoor soil. The results indicate that release and exposure continue for years after cessation of spraying. The predicted cancer risk based on concentrations determined in 2005, indicate that there was still a significant cancer risk up to 13 to 16years after indoor DDT spraying. A novel approach, based on region-specific half-lives, was used to predict concentrations in 2015 and showed that more than 21years after spraying, cancer risk for exposure to indoor air, dust, and outdoor soil are acceptable in Oman for adults and young children. The model can be used for other locations and countries to predict prospective exposure of contaminants based on indoor experimental measurements and knowledge about the spraying time-schedule to extrapolate region-specific half-lives and predict effects on the human population years after spraying. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Lead dust in Broken Hill homes: effect of remediation on indoor lead levels.

    Science.gov (United States)

    Boreland, F; Lyle, D M

    2006-02-01

    This study was undertaken to determine whether home remediation effectively reduced indoor lead levels in Broken Hill, a long-established silver-lead-zinc mining town in outback Australia. A before-after study of the effect of home remediation on indoor lead levels was embedded into a randomized controlled trial of the effectiveness of remediation for reducing elevated blood lead levels in young children. Moist towelettes were used to measure lead loading (microg/m2) on internal windowsills and internal and entry floors of 98 homes; samples were collected before, immediately after, and 2, 4, 6, 8, and 10 months after remediation. Data were log(10) transformed for the analysis. Remediation reduced average indoor lead levels by approximately 50%, and lead levels remained low for the duration of the follow-up period (10 months). The greatest gains were made in homes with the highest initial lead levels; homes with low preremediation lead levels showed little or no benefit. Before remediation, homes located in areas with high soil lead levels or with "poor" dust proofing had higher lead levels than those in areas with lower soil lead levels or with "medium" or "good" dust proofing; these relative differences remained after remediation. There was no evidence that lead loading was reduced by an increased opportunity to become aware of lead issues. We conclude that remediation is an effective strategy for reducing the lead exposure of children living in homes with high indoor lead levels.

  5. Residential indoor air quality guideline : ozone

    International Nuclear Information System (INIS)

    2010-01-01

    Ozone (O 3 ) is a colourless gas that reacts rapidly on surfaces and with other constituents in the air. Sources of indoor O 3 include devices sold as home air cleaners, and some types of office equipment. Outdoor O 3 is also an important contributor to indoor levels of O 3 , depending on the air exchange rate with indoor environments. This residential indoor air quality guideline examined factors that affect the introduction, dispersion and removal of O 3 indoors. The health effects of prolonged exposure to O 3 were discussed, and studies conducted to evaluate the population health impacts of O 3 were reviewed. The studies demonstrated that there is a significant association between ambient O 3 and adverse health impacts. Exposure guidelines for residential indoor air quality were discussed. 14 refs.

  6. [Global air monitoring study: a multi-country comparison of levels of indoor air pollution in different workplaces results from Tunisia].

    Science.gov (United States)

    Higbee, Cheryl; Travers, Mark; Hyland, Andrew; Cummings, K Michael; Dresler, Carolyn

    2007-09-01

    In 1986, a report of the U.S. Surgeon General concluded that second hand smoke is a cause of disease in healthy non smokers. Subsequent many nations including Tunisia implement smoke-free worksite regulations. The aim of our study is to test air quality in indoor ambient air venues in Tunisia. A TSI SidePak AM510 Personal Aerosol Monitor was used to sample, record the levels of respirable suspended particles (RSP) in the air and to assess the real-time concentration of particles less than 2.5 microm in micrograms per cubic meter, or PM2.5. Thirty three venues were sampled in Tunis. The venues were selected to get a broad range of size, location and type of venue. Venues included restaurants and cafés, bars, bus stations, hospitals, offices, and universities. The mean level of indoor air pollution was 296 microg/m3 ranged from 11 microg/m3 to 1,499 microg/m3. The level of indoor air pollution was 85% lower in venues that were smoke-free compared to venues where smoking was observed (ppollution were found in hospitals, offices and universities (52 microg/m3) and the highest level was found in a bar (1,499 micro/m3). Hospitality venues allowing indoor air smoking in Tunisia are significantly more polluted than both indoor smoke-free sites and outdoor air in Tunisia. This study demonstrates that workers and patrons are exposed to harmful levels of a known carcinogen and toxin. Policies that prohibit smoking in public worksites dramatically reduce second hand smoke exposure and improve worker and patron health.

  7. Removal of NO2 and O3 generated from corona discharge in indoor air cleaning with MnO2 catalyst

    International Nuclear Information System (INIS)

    Ge, H; Yu, R; Zhu, Y M; Mi, D

    2013-01-01

    The production rules and removal efficiency of harmful byproducts such as NO 2 and O 3 generated from DC corona discharge in indoor air cleaning were investigated. The production behaviours of NO 2 and O 3 and the relationship between the amount of catalyst (MnO 2 ) and the removal rate of harmful byproducts were experimentally studied. Further, indoor application tests were carried out in a closed room with 90 m 3 . The results showed that the concentrations of NO 2 and O 3 produced by corona discharge linearly increased with discharge time. The NO 2 yield is larger than O 3 by almost one order of magnitude under the same discharge power. To satisfy the demand of Standard of Indoor Air Quality (GB/T18883-2002), the power consumption of unit volume should be less than 1 W m −3 and the catalyst MnO 2 consumptions in positive-negative corona discharge were 200 cm 3 W −1 and 100 cm 3 W −1 , respectively.

  8. Polybrominated diphenyl ethers (PBDEs) in indoor and outdoor window organic films in Izmir, Turkey

    International Nuclear Information System (INIS)

    Cetin, Banu; Odabasi, Mustafa

    2011-01-01

    Polybrominated diphenyl ether (PBDE) concentrations of outdoor and indoor organic films on window glasses were measured at different locations (offices, laboratories, and homes in urban, suburban, rural, and industrial sites) in Izmir, Turkey. Σ 7 PBDE concentrations were dominated by technical penta and deca-BDE mixture components. Average total outdoor PBDE (Σ 7 PBDE) concentrations for suburban, urban, and industrial sites were 43.5, 45.5, and 206 ng m -2 , respectively. This spatial gradient (industrial > urban > suburban concentrations) was similar to one observed for ambient air concentrations recently in Izmir, Turkey. The highest concentrations measured in the industrial area were attributed to the significant PBDE emissions from several steel plants located in the area. Air-organic film partitioning modeling results have suggested that organic films can be used in conjunction with the dynamic uptake model to approximate the gas-phase ambient air concentrations. Modeling results have also indicated that congeners in the gas-phase with very large octanol-air partition coefficients (i.e., BDE-154, -153, and -209) will require several months to approach equilibrium with the surface films. This finding may have important implications for gas-particle and gas-film partitioning, transport, and photolytic degradation of atmospheric PBDEs.

  9. Polybrominated diphenyl ethers (PBDEs) in indoor and outdoor window organic films in Izmir, Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Cetin, Banu [Department of Environmental Engineering, Faculty of Engineering, Dokuz Eylul University, Kaynaklar Campus, 35160 Buca, Izmir (Turkey); Odabasi, Mustafa, E-mail: mustafa.odabasi@deu.edu.tr [Department of Environmental Engineering, Faculty of Engineering, Dokuz Eylul University, Kaynaklar Campus, 35160 Buca, Izmir (Turkey)

    2011-01-30

    Polybrominated diphenyl ether (PBDE) concentrations of outdoor and indoor organic films on window glasses were measured at different locations (offices, laboratories, and homes in urban, suburban, rural, and industrial sites) in Izmir, Turkey. {Sigma}{sub 7}PBDE concentrations were dominated by technical penta and deca-BDE mixture components. Average total outdoor PBDE ({Sigma}{sub 7}PBDE) concentrations for suburban, urban, and industrial sites were 43.5, 45.5, and 206 ng m{sup -2}, respectively. This spatial gradient (industrial > urban > suburban concentrations) was similar to one observed for ambient air concentrations recently in Izmir, Turkey. The highest concentrations measured in the industrial area were attributed to the significant PBDE emissions from several steel plants located in the area. Air-organic film partitioning modeling results have suggested that organic films can be used in conjunction with the dynamic uptake model to approximate the gas-phase ambient air concentrations. Modeling results have also indicated that congeners in the gas-phase with very large octanol-air partition coefficients (i.e., BDE-154, -153, and -209) will require several months to approach equilibrium with the surface films. This finding may have important implications for gas-particle and gas-film partitioning, transport, and photolytic degradation of atmospheric PBDEs.

  10. Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air

    OpenAIRE

    Bartosz Szulczyński; Jacek Gębicki

    2017-01-01

    The paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs) in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric), photoionization and semiconductor with solid electrolyte ones. Commercially available sensors for detection of VOCs and their ...

  11. The effect of the indoor environment on the fate of organic chemicals in the urban landscape.

    Science.gov (United States)

    Cousins, Anna Palm

    2012-11-01

    To assess the effect of the indoor environment on the urban fate of organic chemicals, an 8-compartment indoor-inclusive steady state multimedia chemical fate model was developed. The model includes typical urban compartments (air, soil, water, sediment, and urban film) and a novel module representing a generic indoor environment. The model was parameterized to the municipality of Stockholm, Sweden and applied to four organic chemicals with different physical-chemical characteristics and use patterns: formaldehyde, 2,4,6-tribromophenol, di-ethylhexylphthalate and decabromodiphenyl ether. The results show that emissions to indoor air may increase the steady state mass and residence time in the urban environment by a factor of 1.1 to 22 for the four chemicals, compared to if emissions are assigned to outdoor air. This is due to the nested nature of the indoor environment, which creates a physical barrier that prevents chemicals from leaving the urban system with outflowing air. For DEHP and BDE 209, the additional partitioning to indoor surfaces results in a greater importance of the indoor removal pathways from surfaces. The outdoor environmental concentrations of these chemicals are predicted to be lower if emitted to indoor air than if emitted to outdoor air because of the additional indoor removal pathways of dust and indoor film, leading to loss of chemical from the system. For formaldehyde and 2,4,6-TBP outdoor environmental concentrations are not affected by whether the release occurs indoors or outdoors because of the limited partitioning to indoor surfaces. A sensitivity analysis revealed that there appears to be a relationship between logK(OA) and the impact of the ventilation rate on the urban fate of organic chemicals. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Predicting Use of Outdoor Fall Prevention Strategies: Considerations for Prevention Practices.

    Science.gov (United States)

    Chippendale, Tracy

    2018-01-01

    Outdoor falls are just as common as indoor falls, but have received less attention in research and practice. Behavioral strategies play an important role in outdoor fall prevention. The purpose of this study was to examine predictors of strategy use. Backward stepwise regression was used to study factors associated with use of outdoor fall prevention strategies among a random sample ( N = 120) of community-dwelling seniors. Significant negative predictors of strategy use included higher education levels ( p outdoor fallers and nonfallers in the use of three different types of strategies ( ps outdoor fall prevention strategies. Further study of additional factors is warranted.

  13. Risk of HIV infection among indoor and street sex workers and their use of health services in Belgrade, Serbia

    Directory of Open Access Journals (Sweden)

    Ilić Dragan

    2010-01-01

    Full Text Available Introduction. HIV in Serbia is most often transmitted through sexual contact, and therefore numerous prevention activities are geared towards sex workers (SW. Objective. To analyze the differences in knowledge, attitudes and risky behaviour between indoor and street SW in Belgrade; to examine the accessibility of health services to this vulnerable group. Methods. In this behavioural cross-sectional study, 113 street and 78 indoor SW were included. The sampling method used was snowball samples. Data were gathered through structured questionnaires. Results. Around 15% of respondents used drugs intravenously. Around 60% of SW used a condom during the last sexual intercourse with their private partner, and around 90% with a commercial partner. Indoor SW had lower levels of education more often than outdoor SW, and they used marijuana, sedatives and painkillers on a daily basis. A significantly higher number of indoor SW were informed about HIV, HBV and HCV testing, and that the risk for HIV infection is not lower if a condom is used exclusively for vaginal sex. Indoor SW reported using health services and testing and counseling for HIV, HBV and HCV more frequently than outdoor SW. Outdoor SW had significantly more sex partners in the previous month than indoor SW. Indoor SW recognized more frequently that providing sex services posed a higher risk for HIV infection. Conclusion. The results of this research study show that even though outdoor SW had higher levels of education than indoor SW, their level of knowledge about HIV transmission was lower and they reported more risky behaviour than indoor SW. Data show that both groups reported not taking care of their health.

  14. Polybrominated diphenyl ethers (PBDEs) in the indoor and outdoor environments – A review on occurrence and human exposure

    International Nuclear Information System (INIS)

    Besis, Athanasios; Samara, Constantini

    2012-01-01

    Polybrominated diphenyl ethers (PBDEs) constitute an important group of brominated flame retardants that have been massively produced and extensively used in numerous everyday products, providing longer escape times in case of fire and thus saving lives, as well as reducing the damage of property. In recent years, PBDEs have been recognized as significant pollutants of the indoor environment. This article provides a synthesis and critical evaluation of the state of the knowledge about the occurrence of PBDEs in the indoor environment (air and dust in homes, workplaces and cars) in different countries in Europe, North America, Asia and Australia, as well as about the human exposure via indoor air inhalation and dust ingestion in comparison to outdoor air inhalation and dietary intake. - Although dietary intake is major human exposure route to PBDEs, there is sufficient body of evidence for the ubiquitous presence of these compounds in indoor air and dust, therefore for the potential for significant exposure at work, at home, as well as in closed means of transport.

  15. Indoor environment in Swedish passive houses

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Langer, Sarka; Bloom, Erica Bloom

    2014-01-01

    The purpose of this study was to evaluate the indoor air quality (IAQ) in newly built low energy houses. Measurements were performed in 22 passive houses and 21 conventional buildings during 2012-2013 and 2013-2014 heating seasons. The measured parameters were temperature, relative humidity......, concentration of CO2, NO2, formaldehyde, volatile organic compounds, and live microbiological flora. Air exchange rates (AER) were determined from the concentration-time profiles of CO2. The median AER was slightly higher in the passive houses than in conventional buildings (0.66 h-1 vs. 0.60 h-1). The median...... concentrations in passive houses and conventional buildings were 9.7 and 11 μg/m3, respectively, for NO2, 12 and 16 μg/m3 for formaldehyde, and 230 and 145 μg/m3 for TVOC. The indoor microbiological flora did not differ, with a few exceptions, from outdoors. The IAQ in the passive buildings was judged...

  16. Cardiopulmonary benefits of reducing indoor particles of outdoor origin: a randomized, double-blind crossover trial of air purifiers.

    Science.gov (United States)

    Chen, Renjie; Zhao, Ang; Chen, Honglei; Zhao, Zhuohui; Cai, Jing; Wang, Cuicui; Yang, Changyuan; Li, Huichu; Xu, Xiaohui; Ha, Sandie; Li, Tiantian; Kan, Haidong

    2015-06-02

    Indoor exposure to fine particulate matter (PM2.5) from outdoor sources is a major health concern, especially in highly polluted developing countries such as China. Few studies have evaluated the effectiveness of indoor air purification on the improvement of cardiopulmonary health in these areas. This study sought to evaluate whether a short-term indoor air purifier intervention improves cardiopulmonary health. We conducted a randomized, double-blind crossover trial among 35 healthy college students in Shanghai, China, in 2014. These students lived in dormitories that were randomized into 2 groups and alternated the use of true or sham air purifiers for 48 h with a 2-week washout interval. We measured 14 circulating biomarkers of inflammation, coagulation, and vasoconstriction; lung function; blood pressure (BP); and fractional exhaled nitric. We applied linear mixed-effect models to evaluate the effect of the intervention on health outcome variables. On average, air purification resulted in a 57% reduction in PM2.5 concentration, from 96.2 to 41.3 μg/m3, within hours of operation. Air purification was significantly associated with decreases in geometric means of several circulating inflammatory and thrombogenic biomarkers, including 17.5% in monocyte chemoattractant protein-1, 68.1% in interleukin-1β, 32.8% in myeloperoxidase, and 64.9% in soluble CD40 ligand. Furthermore, systolic BP, diastolic BP, and fractional exhaled nitrous oxide were significantly decreased by 2.7%, 4.8%, and 17.0% in geometric mean, respectively. The impacts on lung function and vasoconstriction biomarkers were beneficial but not statistically significant. This intervention study demonstrated clear cardiopulmonary benefits of indoor air purification among young, healthy adults in a Chinese city with severe ambient particulate air pollution. (Intervention Study on the Health Impact of Air Filters in Chinese Adults; NCT02239744). Copyright © 2015 American College of Cardiology Foundation

  17. Indoor Temperatures in Low Cost Housing in Johannesburg, South Africa.

    Science.gov (United States)

    Naicker, Nisha; Teare, June; Balakrishna, Yusentha; Wright, Caradee Yael; Mathee, Angela

    2017-11-18

    Ambient and indoor temperature affects thermal comfort and human health. In a changing climate with a predicted change in temperature extremes, understanding indoor temperatures, both hot and cold, of different housing types is important. This study aimed to assess the hourly, daily and monthly variation in indoor temperatures in different housing types, namely formal houses, informal houses, flats, government-built low-cost houses and old, apartheid era low-cost housing, in five impoverished urban communities in Johannesburg, South Africa. During the cross-sectional survey of the Health, Environment and Development study data loggers were installed in 100 homes (20 per suburb) from February to May 2014. Indoor temperature and relative humidity were recorded on an hourly basis. Ambient outdoor temperatures were obtained from the nearest weather station. Indoor and outdoor temperature and relative humidity levels were compared; and an inter-comparison between the different housing types were also made. Apparent temperature was calculated to assess indoor thermal comfort. Data from 59 retrieved loggers showed a significant difference in monthly mean indoor temperature between the five different housing types ( p informal settlement houses had the greatest variation in temperature and experienced temperatures between 4 and 5 °C warmer than outdoor temperatures. Housing types occupied by poor communities experienced indoor temperature fluctuations often greater than that observed for ambient temperatures. Families living in government-built low-cost and informally-constructed homes are the most at risk for indoor temperature extremes. These types of housing should be prioritised for interventions aimed at assisting families to cope with extreme temperatures, gaining optimal thermal comfort and preventing temperature-related health effects.

  18. Indoor Temperatures in Low Cost Housing in Johannesburg, South Africa

    Directory of Open Access Journals (Sweden)

    Nisha Naicker

    2017-11-01

    Full Text Available Ambient and indoor temperature affects thermal comfort and human health. In a changing climate with a predicted change in temperature extremes, understanding indoor temperatures, both hot and cold, of different housing types is important. This study aimed to assess the hourly, daily and monthly variation in indoor temperatures in different housing types, namely formal houses, informal houses, flats, government-built low-cost houses and old, apartheid era low-cost housing, in five impoverished urban communities in Johannesburg, South Africa. During the cross-sectional survey of the Health, Environment and Development study data loggers were installed in 100 homes (20 per suburb from February to May 2014. Indoor temperature and relative humidity were recorded on an hourly basis. Ambient outdoor temperatures were obtained from the nearest weather station. Indoor and outdoor temperature and relative humidity levels were compared; and an inter-comparison between the different housing types were also made. Apparent temperature was calculated to assess indoor thermal comfort. Data from 59 retrieved loggers showed a significant difference in monthly mean indoor temperature between the five different housing types (p < 0.0001. Low cost government-built houses and informal settlement houses had the greatest variation in temperature and experienced temperatures between 4 and 5 °C warmer than outdoor temperatures. Housing types occupied by poor communities experienced indoor temperature fluctuations often greater than that observed for ambient temperatures. Families living in government-built low-cost and informally-constructed homes are the most at risk for indoor temperature extremes. These types of housing should be prioritised for interventions aimed at assisting families to cope with extreme temperatures, gaining optimal thermal comfort and preventing temperature-related health effects.

  19. A MIMO-OFDM Testbed, Channel Measurements, and System Considerations for Outdoor-Indoor WiMAX

    Directory of Open Access Journals (Sweden)

    Víctor P. Gil Jiménez

    2010-01-01

    Full Text Available The design, implementation, and test of a real-time flexible 2×2 (Multiple Input Multiple Output-Orthogonal Frequency Division Multiplexing MIMO-OFDM IEEE 802.16 prototype are presented. For the design, a channel measurement campaign on the 3.5 GHz band has been carried out, focusing on outdoor-indoor scenarios. The analysis of measured channels showed that higher capacity can be achieved in case of obstructed scenarios and that (Channel Distribution Information at the Transmitter CDIT capacity is close to (Channel State Information at the Transmitter CSIT with much lower complexity and requirements in terms of channel estimation and feedback. The baseband prototype used an (Field Programmable Gate Array FPGA where enhanced signal processing algorithms are implemented in order to improve system performance. We have shown that for MIMO-OFDM systems, extra signal processing such as enhanced joint channel and frequency offset estimation is needed to obtain a good performance and approach in practice the theoretical capacity improvements.

  20. Long term and equilibrium factor indoor radon measurements

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Navarrete, M.; Cabrera, L.; Ramirez, A.; Elizarraras, V.

    1998-01-01

    This paper presents the annual radon gas concentrations obtained during the 1994-1995 monitoring campaign using passive electret system (type E-PERM). Radon levels were measured in 154 single family dwellings, in normal occupancy conditions (open house condition) in the metropolitan zone of Mexico City. At the same time radon monitoring was performed outdoors. The results show the general log-normal distribution of integrated indoor radon concentration with an annual indoor mean of 3.8 pCi x l -1 . The seasonal variations show the minimum mean values in the summer season which are 39% lower than that in autumn. Equilibrium factors (F) were measured in 12 typical houses both in autumn and winter using a continuous working level monitor for short-lived radon decay products and H-chamber loaded with a short term electret (HST, E-PERM) for radon gas. The obtained total mean equilibrium factors are: F=0.41±0.17 and F=0.29±0.04 for indoor and outdoor, respectively. A quality program was also improved. (author)

  1. Indoor particle dynamics in a school office: determination of particle concentrations, deposition rates and penetration factors under naturally ventilated conditions.

    Science.gov (United States)

    Cong, X C; Zhao, J J; Jing, Z; Wang, Q G; Ni, P F

    2018-05-09

    Recently, the problem of indoor particulate matter pollution has received much attention. An increasing number of epidemiological studies show that the concentration of atmospheric particulate matter has a significant effect on human health, even at very low concentrations. Most of these investigations have relied upon outdoor particle concentrations as surrogates of human exposures. However, considering that the concentration distribution of the indoor particulate matter is largely dependent on the extent to which these particles penetrate the building and on the degree of suspension in the indoor air, human exposures to particles of outdoor origin may not be equal to outdoor particle concentration levels. Therefore, it is critical to understand the relationship between the particle concentrations found outdoors and those found in indoor micro-environments. In this study, experiments were conducted using a naturally ventilated office located in Qingdao, China. The indoor and outdoor particle concentrations were measured at the same time using an optical counter with four size ranges. The particle size distribution ranged from 0.3 to 2.5 μm, and the experimental period was from April to September, 2016. Based on the experimental data, the dynamic and mass balance model based on time was used to estimate the penetration rate and deposition rate at air exchange rates of 0.03-0.25 h -1 . The values of the penetration rate and deposition velocity of indoor particles were determined to range from 0.45 to 0.82 h -1 and 1.71 to 2.82 m/h, respectively. In addition, the particulate pollution exposure in the indoor environment was analyzed to estimate the exposure hazard from indoor particulate matter pollution, which is important for human exposure to particles and associated health effects. The conclusions from this study can serve to provide a better understanding the dynamics and behaviors of airborne particle entering into buildings. And they will also highlight

  2. Size specific indoor aerosol deposition measurements and derived I/O concentrations ratios

    DEFF Research Database (Denmark)

    Fogh, C.L.; Byrne, M.A.; Roed, Jørn

    1997-01-01

    The process of aerosol deposition on indoor surfaces has implications for human exposure to particulate contaminants of both indoor and outdoor origin. In the radiological context, current accident models assume a uniform Dose Reduction Factor (DRF) of 0.5 for indoor residence during the outdoor...

  3. Indoor air quality levels in a University Hospital in the Eastern Province of Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Mahmoud F El-Sharkawy

    2014-01-01

    Full Text Available Aim of the Study: The complex hospital environment requires special attention to ensure a healthy indoor air quality (IAQ to protect patients and healthcare workers against hospital-acquired infections and occupational diseases. Poor hospital IAQ may cause outbreaks of building-related illness such as headaches, fatigue, eye, and skin irritations, and other symptoms. The general objective for this study was to assess IAQ inside a large University hospital at Al-Khobar City in the Eastern Province of Saudi Arabia. Materials and Methods: Different locations representing areas where most activities and tasks are performed were selected as sampling points for air pollutants in the selected hospital. In addition, several factors were studied to determine those that were most likely to affect the IAQ levels. The temperature and relative percent humidity of different air pollutants were measured simultaneously at each location. Results: The outdoor levels of all air pollutant levels, except volatile organic compounds (VOCs, were higher than the indoor levels which meant that the IAQ inside healthcare facilities (HCFs were greatly affected by outdoor sources, particularly traffic. The highest levels of total suspended particulates (TSPs and those less than 10 microns (PM 10 inside the selected hospital were found at locations that are characterized with m4ore human activity. Conclusions:Levels of particulate matter (both PM 10 and TSP were higher than the Air Quality Guidelines (AQGs. The highest concentrations of the fungal species recorded were Cladosporium and Penicillium. Education of occupants of HCF on IAQ is critical. They must be informed about the sources and effects of contaminants and the proper operation of the ventilation system.

  4. Light-induced nitrous acid (HONO) production from NO2 heterogeneous reactions on household chemicals

    Science.gov (United States)

    Gómez Alvarez, Elena; Sörgel, Matthias; Gligorovski, Sasho; Bassil, Sabina; Bartolomei, Vincent; Coulomb, Bruno; Zetzsch, Cornelius; Wortham, Henri

    2014-10-01

    Nitrous acid (HONO) can be generated in various indoor environments directly during combustion processes or indirectly via heterogeneous NO2 reactions with water adsorbed layers on diverse surfaces. Indoors not only the concentrations of NO2 are higher but the surface to volume (S/V) ratios are larger and therefore the potential of HONO production is significantly elevated compared to outdoors. It has been claimed that the UV solar light is largely attenuated indoors. Here, we show that solar light (λ > 340 nm) penetrates indoors and can influence the heterogeneous reactions of gas-phase NO2 with various household surfaces. The NO2 to HONO conversion mediated by light on surfaces covered with domestic chemicals has been determined at atmospherically relevant conditions i.e. 50 ppb NO2 and 50% RH. The formation rates of HONO were enhanced in presence of light for all the studied surfaces and are determined in the following order: 1.3·109 molecules cm-2 s-1 for borosilicate glass, 1.7·109 molecules cm-2 s-1 for bathroom cleaner, 1.0·1010 molecules cm-2 s-1 on alkaline detergent (floor cleaner), 1.3·1010 molecules cm-2 s-1 for white wall paint and 2.7·1010 molecules cm-2 s-1 for lacquer. These results highlight the potential of household chemicals, used for cleaning purposes to generate HONO indoors through light-enhanced NO2 heterogeneous reactions. The results obtained have been applied to predict the timely evolution of HONO in a real indoor environment using a dynamic mass balance model. A steady state mixing ratio of HONO has been estimated at 1.6 ppb assuming a contribution from glass, paint and lacquer and considering the photolysis of HONO as the most important loss process.

  5. Moulds and indoor air quality - a man-made problem

    International Nuclear Information System (INIS)

    Langvad, Finn

    2002-01-01

    In the 1970s and 1980s, many house owners in Norway, in order to save energy, insulated their houses by injecting torn-up mineral wool into the entire cavity of the wall. This made the house warmer to live in, but it also created serious condensation problems followed by rot and mould. The extensive use of gypsum boards is also alarming. If gypsum becomes really wet because of a water leakage, it becomes a ticking bomb from the micro-biologic point of view as it provides growth conditions for some of the most dangerous indoor mould fungi known, the Stachybotrys chart arum. The article discusses the danger of this fungus and surveys some of the ways that mould affect human health. There is at present no definition of a normal number of fungus spores per unit volume of air. But the following principles can be taken as guidelines: (1) The concentration of spores indoor must be lower than outdoors. Otherwise extra spores have been generated in the house. (2) The species composition of the air must be approximately the same indoors and outdoors

  6. The effect of deltamethrin-treated net fencing around cattle enclosures on outdoor-biting mosquitoes in Kumasi, Ghana.

    Directory of Open Access Journals (Sweden)

    Marta Ferreira Maia

    Full Text Available Classic vector control strategies target mosquitoes indoors as the main transmitters of malaria are indoor-biting and -resting mosquitoes. However, the intensive use of insecticide-treated bed-nets (ITNs and indoor residual spraying have put selective pressure on mosquitoes to adapt in order to obtain human blood meals. Thus, early-evening and outdoor vector activity is becoming an increasing concern. This study assessed the effect of a deltamethrin-treated net (100 mg/m(2 attached to a one-meter high fence around outdoor cattle enclosures on the number of mosquitoes landing on humans. Mosquitoes were collected from four cattle enclosures: Pen A - with cattle and no net; B - with cattle and protected by an untreated net; C - with cattle and protected by a deltamethrin-treated net; D - no cattle and no net. A total of 3217 culicines and 1017 anophelines were collected, of which 388 were Anopheles gambiae and 629 An. ziemanni. In the absence of cattle nearly 3 times more An. gambiae (p<0.0001 landed on humans. The deltamethrin-treated net significantly reduced (nearly three-fold, p<0.0001 culicine landings inside enclosures. The sporozoite rate of the zoophilic An. ziemanni, known to be a secondary malaria vector, was as high as that of the most competent vector An. gambiae; raising the potential of zoophilic species as secondary malaria vectors. After deployment of the ITNs a deltamethrin persistence of 9 months was observed despite exposure to African weather conditions. The outdoor use of ITNs resulted in a significant reduction of host-seeking culicines inside enclosures. Further studies investigating the effectiveness and spatial repellence of ITNs around other outdoor sites, such as bars and cooking areas, as well as their direct effect on vector-borne disease transmission are needed to evaluate its potential as an appropriate outdoor vector control tool for rural Africa.

  7. Effects of Outdoor Housing of Piglets on Behavior, Stress Reaction and Meat Characteristics

    Directory of Open Access Journals (Sweden)

    Tomohiro Yonezawa

    2012-06-01

    Full Text Available Well-designed housing systems are important from the viewpoint of animal welfare and improvement of meat production. In this study, we investigated the effects of outdoor housing of pigs on their behavior, cortisol levels, and meat characteristics. Two groups that were born and raised in a spacious outdoor pen (4×10 m for every two sows or a minimum-sized standard pen in a piggery (1.9×2.2 m for every sow were studied. When their behaviors at the age of 2 to 3 wk were observed, the number of rooting episodes tended to be larger (p = 0.0509 and the total time of rooting tended to be longer (p = 0.0640 in the outdoor-housed piglets although the difference was not significant. Basal salivary cortisol levels of the outdoor piglets at the age of 4 wk were significantly lower than those of the indoor piglets (5.0±0.59 ng/ml vs. 11.6±0.91 ng/ml, 30 min after treatment, although their plasma cortisol levels were similar (53.3±3.54 ng/ml vs. 59.9±4.84 ng/ml, 30 min after treatment. When the ears were pierced at weaning, plasma and salivary cortisol levels were increased in both groups, even at 15 min after piercing. However, the increase in the outdoor-housed group was significantly less than that in the indoor-housed group. Throughout their lives, body weight and daily gain of the pigs were not significantly different between the two groups. In a meat taste preference test taken by 20 panelists, saltiness, flavor, and color of the outdoor-housed pork were found to be more acceptable. Moreover, when an electronic taste-sensing device was utilized, the C00 and CPA-C00 outputs (3.78±0.07 and −0.20±0.023, which correspond to compounds of bitterness and smells, respectively, were significantly lower in the outdoor-housed pork (5.03±0.16 and −0.13±0.009. Our results demonstrate that the outdoor housing system for piglets induces natural behaviors such as rooting and suppresses the strongest stress reaction of piglets, which could be important

  8. Multi-dimensional indoor location information model

    NARCIS (Netherlands)

    Xiong, Q.; Zhu, Q.; Zlatanova, S.; Huang, L.; Zhou, Y.; Du, Z.

    2013-01-01

    Aiming at the increasing requirements of seamless indoor and outdoor navigation and location service, a Chinese standard of Multidimensional Indoor Location Information Model is being developed, which defines ontology of indoor location. The model is complementary to 3D concepts like CityGML and

  9. Mesoporous perovskite solar cells and the role of nanoscale compact layers for remarkable all-round high efficiency under both indoor and outdoor illuminiation

    NARCIS (Netherlands)

    Di Giacomo, F.; Zardetto, V.; Lucarelli, G.; Cina, L.; Di Carlo, A.; Creatore, M.; Brown, T.M.

    2016-01-01

    Today poly and mono-crystalline silicon dominate the photovoltaic (PV) markets for outdoor applications. Nevertheless, there is a growing requirement for PV to be deployed in a wide variety of conditions from building-integrated, to portable electronics, to indoors for powering smart sensors,

  10. Simulating Real-World Exposures during Emergency Events: Studying Effects of Indoor and Outdoor Releases in the Urban Dispersion Project in Upper Manhattan, NY

    Science.gov (United States)

    A prospective personal exposure study, involving indoor and outdoor releases, was conducted in upper Midtown Manhattan in New York City as part of the Urban Dispersion Program (UDP) focusing on atmospheric dispersion of chemicals in complex urban settings. The UDP experiments inv...

  11. Changes to indoor air quality as a result of relocating families from slums to public housing

    Science.gov (United States)

    Burgos, Soledad; Ruiz, Pablo; Koifman, Rosalina

    2013-05-01

    One largely unstudied benefit of relocating families from slums to public housing is the potential improvement in indoor air quality (IAQ). We compared families that moved from slums to public housing with those that remained living in slums in Santiago, Chile in terms of fine particulate matter (PM2.5) as main indicator of change. A cross-sectional study of 98 relocated families and 71 still living in slums was carried out, obtaining indoor and outdoor samples by a Personal Environmental Monitor. Home characteristics, including indoor air pollution sources were collected through questionnaires. Multivariate regression models included the intervention (public housing or slum), indoor pollution sources, outdoor PM2.5 and family characteristics as predictors. Indoor PM2.5 concentrations were higher in slums (77.8 μg m-3 [SD = 35.7 μg m-3]) than in public housing (55.7 μg m-3 [SD = 34.6 μg m-3], p slum houses. The multivariate analysis showed that housing intervention significantly decreased indoor PM2.5 (10.4 μg m-3) after adjusting by the other predictors. Outdoor PM2.5 was the main predictor of indoor PM2.5. Other significant factors were water heating fuels and indoor smoking. Having infants 1-23 months was associated with a lowering of indoor PM2.5. Our results suggest that a public housing program that moves families from slums to public housing improves indoor air quality directly and also indirectly through air pollution sources.

  12. Indoor Climate of Large Glazed Spaces

    DEFF Research Database (Denmark)

    Hendriksen, Ole Juhl; Madsen, Christina E.; Heiselberg, Per

    In recent years large glazed spaces has found increased use both in connection with renovation of buildings and as part of new buildings. One of the objectives is to add an architectural element, which combines indoor- and outdoor climate. In order to obtain a satisfying indoor climate it is crui...... it is cruicial at the design stage to be able to predict the performance regarding thermal comfort and energy consumption. This paper focus on the practical implementation of Computational Fluid Dynamics (CFD) and the relation to other simulation tools regarding indoor climate.......In recent years large glazed spaces has found increased use both in connection with renovation of buildings and as part of new buildings. One of the objectives is to add an architectural element, which combines indoor- and outdoor climate. In order to obtain a satisfying indoor climate...

  13. Reducing burden of disease from residential indoor air exposures in Europe (HEALTHVENT project)

    DEFF Research Database (Denmark)

    Asikainen, Arja; Carrer, Paolo; Kephalopoulos, Stylianos

    2016-01-01

    ), approximately 90 % of EU citizens live in areas where the World Health Organization (WHO) guidelines for air quality of particulate matter sized PM2.5) are not met. Since sources of pollution reside in both indoor and outdoor air, selecting the most appropriate ventilation strategy is not a simple...... matter (PM2.5), outdoor bioaerosols, volatile organic compounds (VOC), carbon oxide (CO) radon and dampness was estimated. The analysis was based on scenario comparison, using an outdoor-indoor mass-balance model and varying the ventilation rates. Health effects were estimated with burden of diseases (Bo...... air; and (iii) indoor source control, showed that all three approaches are able to provide substantial reductions in the health risks, varying from approximately 20 % to 44 %, corresponding to 400 000 and 900 000 saved healthy life years in EU-26. PM2.5 caused majority of the health effects in all...

  14. Indoor radon concentration levels in Amman, Zarka and Sault

    International Nuclear Information System (INIS)

    Khatibeh, A.J.A.H.; Ahmad, N.; Matiullah, A.

    1997-01-01

    Indoor radon concentration levels in three main cities of Jordan have been measured using CR-39 polymeric nuclear track detectors. CR-39 detectors were placed in polyethylene bags and cups. These bag and cup dosimeters were installed in randomly selected houses. The average value of indoor radon concentration level in the city of Amman was found to be 41.3 Bq m -3 with cup dosimeters and 42.6 Bq m -3 with bag dosimeters. For the district of Zarka, the average value of indoor radon concentration level measured with bag dosimeters was 33.9 Bq m -3 , whereas with cup dosimeters the level was 30.7 Bq m -3 . For Sault and its suburbs, the average value of indoor radon concentration level was found to be 51.2 Bq m -3 with bag dosimeters and 49.8 Bq m -3 with cup dosimeters. (author)

  15. Evaluation of Spectrum Usage for GSM band in Indoor and Outdoor Scenario for Dynamic Spectrum Access

    DEFF Research Database (Denmark)

    Patil, Kishor P.; Barge, Snehal; Skouby, Knud Erik

    2013-01-01

    , and transmit power. Several measurements have shown that the current spectrum is inefficiently utilized. The inefficient utilization problem can be solved with the help of Dynamic Spectrum Access. This paper describes the GSM band measurement conducted at different locations. In this paper, we report detailed...... measurement results of GSM band including statistical as well as spectral occupancy details obtained from measurement campaign conducted in Pune, India for indoor and outdoor scenarios. The results can be further used as an input for spectrum regulator for considering Cognitive Radio (CR) operation in GSM...

  16. Radon Concentration in Outdoors and Indoors Around the Flare in Oil Mine Sites; Konsentrasi Gas Radon di Udara di Luar dan Dalam Rumah Sekitar Nyala-api Kawasan Tambang Minyak

    Energy Technology Data Exchange (ETDEWEB)

    Sutarman,; Wahyudi, [Centre for Research and Development of Radiation Safety and Nuclear Biomedicine, National Nuclear Energy Agency, Jakarta (Indonesia); Luhantara, [University of Indonesia, Jakarta (Indonesia)

    2003-03-15

    The flares are much found at the oil exploration areas which appear the combustion gases emission to the environment that pass through a pipe at about 8 m high from the ground level. The flare is released into the environment together with the hydrocarbon and radon gases. This study has been carried out the measurement of the radon gas concentration only. Radon is a radioactive gas which comes from the natural radioactive decay of uranium ({sup 238}U). The outdoor radon concentrations were measured in 23 locations with the two-filter method. The locations were determined by a circle which the flare as the point center. The outdoor radon concentrations were measured in 74 houses (more than distance of 600 m from the flare) with the alpha track detector (CR-39) placed in the living rooms for about three months. The measurements of the radon concentrations were carried out in Cepu, Cirebon, and Prabumulih oil mine sites. The results showed that the outdoor radon concentrations a range of 108 Bq/m{sup 3} to 256 Bq/m{sup 3} in Cepu, 248 Bq/m{sup 3} to 3525 Bq/m{sup 3} in Cirebon, and 51 Bq/m{sup 3} to 114 Bq/m{sup 3} in Prabumulih. The results showed that the indoor radon concentrations a range of 11 Bq/m{sup 3} to 38 Bq/m{sup 3} in Cepu, 28 Bq/m{sup 3} to 184 Bq/m{sup 3} in Cirebon, and 12 Bq/m{sup 3} to 38 Bq/m{sup 3} in Prabumulih. The data of the maximum radon concentration in outdoor air was higher than an actual level which recommended by International Atomic Energy Agency (IAEA) for workplaces. The maximum radon concentration in indoor air was lower than an actual level which recommended by IAEA for dwellings. IAEA recommends the actual level of 1000 Bq/m{sup 3} for workplaces and 200 Bq/m{sup 3} for dwellings. These data will be used for the baseline data of the environmental radioactivity in Indonesia. (author)

  17. In- and outdoor reproduction of first generation common sole Solea solea under a natural photothermal regime: Temporal progression of sexual maturation assessed by monitoring plasma steroids and gonadotropin mRNA expression.

    Science.gov (United States)

    Palstra, A P; Blok, M C; Kals, J; Blom, E; Tuinhof-Koelma, N; Dirks, R P; Forlenza, M; Blonk, R J W

    2015-09-15

    Reproduction of many temperate fishes is seasonal and maturation and spawning of gametes are under photothermal control. Reproductive success of first generation (G1) common sole Solea solea in captivity has been low. In this study, the sexual maturation status has been assessed during the prespawning months in G1 sole that were housed (a) outdoor under the natural photoperiod and temperature, or (b) indoor under artificial photothermal induction. Maturation was assessed in male and female G1 broodstock in November as controls, after which the remaining population was divided over two outdoor flow-through tanks placed in a pond and two indoor recirculating aquaculture system (RAS) tanks. Subsequently, maturation status (gonadosomatic index GSI and plasma levels of testosterone T and 17β-estradiol E2) was assessed in one tank for each condition in January, February and during spawning in early April, while fish in the other tank were not disturbed in achieving reproductive success. Quantitative real-time PCR was performed to determine species-specific gonadotropin mRNA expression in females. Successful G1 spawning and egg fertilisation occurred in all experimental tanks. Gonadal development was similar under both conditions. Higher E2 and T levels were found in indoor housed females. Gonadotropin expression revealed similar profiles between outdoor and indoor housed females. G1 sole could be reproduced in the outdoor tanks under the natural photoperiod and in the indoor tanks under artificial simulation of this regime that includes a potentially crucial chilling period of 2-3 months at 5-7 °C. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Risk evaluation and control strategies for indoor radon: a brief discussion

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1994-01-01

    Average risks of death estimated for radon are larger than those for many exposures in the outdoor environment, but similar to some in industrial settings. However, the indoor environment differs in regard to cost, benefit, responsibility, and distribution of risks from the outdoor and occupational settings, where frameworks for setting risk-limiting objectives and strategies have already been developed substantially. This indicates the need to develop a conceptual framework for evaluating risks in the indoor environment, within which the objectives of radon control strategies can be sensibly chosen. Nevertheless, the range of estimated radon risks and of recent radon control strategies suggest near-term elements of any strategy, i.e. accurate and effective public information, as well as reliable monitoring and control capabilities, and a focus on areas where most high residential levels occur. Developing a conceptual framework for evaluating indoor risks will permit the formulation of suitable aims on average indoor exposures and lower exposure situations. (author)

  19. A survey of indoor pollution by volatile organo halogen compounds in Katsushika, Tokyo, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Amagai, T.; Olansandan; Matsushita, H. [University of Shizuoka, Shizuoka (Japan); Ono, M. [National Institute for Environmental Studies, Ibaraki (Japan); Nakai, S. [Yokohama National University, Yokohama (Japan); Tamura, K. [National Institute for Minamata Disease, Kumamoto (Japan); Maeda, K. [Tokyo Kasel University, Tokyo (Japan)

    1999-07-01

    A survey of indoor and outdoor pollution by 10 volatile organo halogen compounds (VOHCs) was performed in Katsushika Ward, Tokyo, Japan. Thirteen houses in February and 30 houses in July were sampled. Four consecutive 24-hour samples were collected by passive sampling from living room, kitchen, bedroom, bathroom and outdoors in February and July 1995. Indoor concentrations of carbon tetrachloride and trichloroethylene were at nearly the same as outdoor concentrations; therefore, it was concluded that indoor pollution by these compounds was primarily due to penetration of outdoor pollutants. Indoor concentrations of some VOHCs were considerably higher than outdoor concentrations and they varied widely between households. The list included: p-dichlorobenzene, tetrachloroethylene and tri halomethanes, for which emission sources were insect repellents, dry-cleaned clothes, and tap water, showers and bathtub water, respectively. Indoor concentrations of these compounds were higher in reinforced concrete houses than in wooden houses or wooden houses with mortar walls. This suggests that airtightness of the rooms is responsible for high indoor VOHC concentrations. (author)

  20. Comparison of the CDC Backpack aspirator and the Prokopack aspirator for sampling indoor- and outdoor-resting mosquitoes in southern Tanzania

    Directory of Open Access Journals (Sweden)

    Mgando Joseph

    2011-06-01

    Full Text Available Abstract Background Resting mosquitoes can easily be collected using an aspirating device. The most commonly used mechanical aspirator is the CDC Backpack aspirator. Recently, a simple, and low-cost aspirator called the Prokopack has been devised and proved to have comparable performance. The following study evaluates the Prokopack aspirator compared to the CDC backpack aspirator when sampling resting mosquitoes in rural Tanzania. Methods Mosquitoes were sampled in- and outdoors of 48 typical rural African households using both aspirators. The aspirators were rotated between collectors and households in a randomized, Latin Square design. Outdoor collections were performed using artificial resting places (large barrel and car tyre, underneath the outdoor kitchen (kibanda roof and from a drop-net. Data were analysed with generalized linear models. Results The number of mosquitoes collected using the CDC Backpack and the Prokopack aspirator were not significantly different both in- and outdoors (indoors p = 0.735; large barrel p = 0.867; car tyre p = 0.418; kibanda p = 0.519. The Prokopack was superior for sampling of drop-nets due to its smaller size. The number mosquitoes collected per technician was more consistent when using the Prokopack aspirator. The Prokopack was more user-friendly: technicians preferred using the it over the CDC backpack aspirator as it weighs considerably less, retains its charge for longer and is easier to manoeuvre. Conclusions The Prokopack proved in the field to be more advantageous than the CDC Backpack aspirator. It can be self assembled using simple, low-cost and easily attainable materials. This device is a useful tool for researchers or vector-control surveillance programs operating in rural Africa, as it is far simpler and quicker than traditional means of sampling resting mosquitoes. Further longitudinal evaluations of the Prokopack aspirator versus the gold standard pyrethrum spray catch for indoor resting

  1. Indoor acrolein emission and decay rates resulting from domestic cooking events

    Science.gov (United States)

    Seaman, Vincent Y.; Bennett, Deborah H.; Cahill, Thomas M.

    2009-12-01

    Acrolein (2-propenal) is a common constituent of both indoor and outdoor air, can exacerbate asthma in children, and may contribute to other chronic lung diseases. Recent studies have found high indoor levels of acrolein and other carbonyls compared to outdoor ambient concentrations. Heated cooking oils produce considerable amounts of acrolein, thus cooking is likely an important source of indoor acrolein. A series of cooking experiments were conducted to determine the emission rates of acrolein and other volatile carbonyls for different types of cooking oils (canola, soybean, corn and olive oils) and deep-frying different food items. Similar concentrations and emission rates of carbonyls were found when different vegetable oils were used to deep-fry the same food product. The food item being deep-fried was generally not a significant source of carbonyls compared to the cooking oil. The oil cooking events resulted in high concentrations of acrolein that were in the range of 26.4-64.5 μg m -3. These concentrations exceed all the chronic regulatory exposure limits and many of the acute exposure limits. The air exchange rate and the decay rate of the carbonyls were monitored to estimate the half-life of the carbonyls. The half-life for acrolein was 14.4 ± 2.6 h, which indicates that indoor acrolein concentrations can persist for considerable time after cooking in poorly-ventilated homes.

  2. Climate change consequences for the indoor environment

    NARCIS (Netherlands)

    Ariës, M.B.C.; Bluyssen, P.M.

    2009-01-01

    Scientists warn us about climate change and its effects on the outdoor environment. These effects can have significant consequences for the indoor environment, also in the Netherlands. Climate changes will affect different aspects of the indoor environment as well as the stakeholders of that indoor

  3. Radon and NO2 levels and related environmental factors in 100 underground subway platforms over two-year period.

    Science.gov (United States)

    Hwang, Sung Ho; Park, Jae Bum; Park, Wha Me

    2018-01-01

    In this study, the environmental factors that affect radon (Rn) and nitrogen dioxide (NO 2 ) levels in subway-station underground platforms are evaluated, and the outdoor NO 2 levels are compared with those obtained for the underground platforms. The Rn and NO 2 levels from May 2013 to September 2015 are determined for lines 1-4 of the Seoul Metro, via calculation of the arithmetic means of the Rn and NO 2 levels with their standard deviations (SDs). The underground Rn levels in 2013 are found to be significantly higher than those recorded in 2015 for the Seoul Metro. In addition, the Rn levels are related to the station depth and construction year. Further, the underground NO 2 levels are shown to be significantly higher than the outdoor levels for all four Seoul Metro subway lines. The Rn levels are also found to vary significantly between months, and are shown to increase gradually with depth from 8 to 20 m. The Rn levels are also higher for stations constructed in the 1980s. Therefore, stricter monitoring of Rn level may be required for stations constructed in the 1980s and/or having platform depths within the 8-20 m range. Island-type platform stations based on granite areas may also require careful attention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Exposure to unusually high indoor radon levels

    International Nuclear Information System (INIS)

    Rasheed, F.N.

    1993-01-01

    Unusually high indoor radon concentrations were reported in a small village in western Tyrol, Austria. The authors have measured the seasonal course of indoor radon concentrations in 390 houses of this village. 71% of houses in winter and 33% in summer, showed radon values on the ground floor above the Austrian action level of 400 Bq/cm 3 . This proportion results in an unusually high indoor radon exposure of the population. The radon source was an 8,700-year-old rock slide of granite gneiss, the largest of the alpine crystalline rocks. It has a strong emanating power because its rocks are heavily fractured and show a slightly increased uranium content. Previous reports show increased lung cancer mortality, myeloid leukemia, kidney cancer, melanoma, and prostate cancer resulting from indoor radon exposure. However, many studies fail to provide accurate information on indoor radon concentrations, classifying them merely as low, intermediate, and high, or they record only minor increases in indoor radon concentrations. Mortality data for 1970-91 were used to calculate age and sex standardized mortality rates (SMR) for 51 sites of carcinoma. The total population of Tyrol were controls. A significantly higher risk was recorded for lung cancer. The high SMR for lung cancer in female subjects is especially striking. Because the numbers were low for the other cancer sites, these were combined in one group to calculate the SMR. No significant increase in SMR was found for this group

  5. Outdoor exercise, well-being and connectedness to nature = Exercício físico outdoor, bem-estar e conectividade com a natureza = Ejercicio físico outdoor, bienestar y conectividad con la naturaleza

    Directory of Open Access Journals (Sweden)

    Loureiro, Ana

    2014-01-01

    Full Text Available Os benefícios do contacto com a natureza no bem-estar são suportados pela pesquisa sobre ambientes restauradores. Estudos na área do exercício físico reconhecem igualmente benefícios físicos e psicológicos do exercício outdoor, particularmente em ambientes naturais. Combinando estas duas áreas, pretendemos estudar a relação entre o exercício físico outdoor e o bem-estar, e o papel da conectividade com a natureza nessa relação. Participam 282 praticantes de exercício físico, que responderam a um questionário relatando o nível de actividade física, a experiência subjectiva com o exercício, o estado afectivo e a conectividade com a natureza. Os resultados mostram que os praticantes de exercício outdoor e indoor relatam mais emoções positivas e melhor bem-estar associado ao exercício que os praticantes apenas indoor. Além disso, a conectividade com a natureza é um preditor do bem-estar naquele grupo de praticantes. Discutem-se as implicações dos benefícios do exercício outdoor na promoção de estilos de vida saudáveis

  6. A Robust Method for Detecting Parking Areas in Both Indoor and Outdoor Environments

    Directory of Open Access Journals (Sweden)

    Wenhao Zong

    2018-06-01

    Full Text Available Although an automatic parking system has been installed in many vehicles recently, it is still hard for the system to confirm by itself whether a vacant parking area truly exists or not. In this paper, we introduced a robust vision-based vacancy parking area detecting method for both indoor and outdoor environments. The main contribution of this paper is given as follows. First, an automatic image stitching method is proposed. Secondly, the problem of environment illuminating change and line color difference is considered and solved. Thirdly, the proposed algorithm is insensitive to the shadow and scene diversity, which means the detecting result satisfies most of the environment. Finally, a vehicle model is considered for tracking and reconfirming the detecting results to eliminate most of the false positives.

  7. An investigation of factors influencing indoor radon concentrations

    International Nuclear Information System (INIS)

    Majborn, B.; Soerensen, A.; Nielsen, S.P.; Boetter-Jensen, L.

    1988-05-01

    Variations in indoor radon concentrations and some influencing factors have been studied during a two-year period (1986-1987) in 16 almost identical single-family houses.The annual average radon concentration in the houses varied from about 50 to about 400 Bq/m 3 . Variations in soil characteristics and radon concentration in soil gas could not be directly related to the variations of the average indoor radon concentrations. Most of the houses showed a ''normal'' seasonal variation of the radon concentration with a maximum in the winter and minimum in the summer. A deviating seasonal variation was found in three of the houses. Hourly data obtained in one unoccupied house during a period of 2-1/2 months showed no or only weak correlations between the indoor radon concentration and meteorological factors. However, for most of the houses, the seasonal variation of the indoor radon concentration was well correlated with the average indoor-outdoor temperature difference on a 2-month basis. It was demonstrated that the radon concentration can be strongly reduced in the Risoe houses if a district-heating duct, which is connected to all the houses, is ventilated, so that a slightly lowered pressure is maintained in the duct. 5 taps., 24 ill. (author)

  8. Integration of Kinect and Low-Cost Gnss for Outdoor Navigation

    Science.gov (United States)

    Pagliaria, D.; Pinto, L.; Reguzzoni, M.; Rossi, L.

    2016-06-01

    Since its launch on the market, Microsoft Kinect sensor has represented a great revolution in the field of low cost navigation, especially for indoor robotic applications. In fact, this system is endowed with a depth camera, as well as a visual RGB camera, at a cost of about 200. The characteristics and the potentiality of the Kinect sensor have been widely studied for indoor applications. The second generation of this sensor has been announced to be capable of acquiring data even outdoors, under direct sunlight. The task of navigating passing from an indoor to an outdoor environment (and vice versa) is very demanding because the sensors that work properly in one environment are typically unsuitable in the other one. In this sense the Kinect could represent an interesting device allowing bridging the navigation solution between outdoor and indoor. In this work the accuracy and the field of application of the new generation of Kinect sensor have been tested outdoor, considering different lighting conditions and the reflective properties of the emitted ray on different materials. Moreover, an integrated system with a low cost GNSS receiver has been studied, with the aim of taking advantage of the GNSS positioning when the satellite visibility conditions are good enough. A kinematic test has been performed outdoor by using a Kinect sensor and a GNSS receiver and it is here presented.

  9. Indoor ran don concentration. Temperature and wind effects

    International Nuclear Information System (INIS)

    Sesana, L.; Benigni, S.

    2000-01-01

    The present study analyses and discusses the behaviour of the indoor radon concentration in a research house. Hourly measurements were carried out in the basement of the house from November 1998 up to June 1999. In many sequences of days radon concentration in the room under analysis shows strong variation all day long with accumulation in the evening and overnight and decrease in the morning and in the afternoon. Measurements of wind velocity, indoor and outdoor temperatures and outdoor-indoor pressure difference were performed and their trend is compared with the observed radon concentration. The exhalation of radon from walls, floor and ceiling and the pressure difference driven exhalation from the soil are discussed, particularly the relation with the temperature differences. The air exchange rates between the house and the outdoor air are studied [it

  10. Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system.

    Science.gov (United States)

    Bonetta, Sa; Bonetta, Si; Mosso, S; Sampò, S; Carraro, E

    2010-02-01

    The purpose of this study was to evaluate the level and composition of bacteria and fungi in the indoor air of an Italian office building equipped with a heating, ventilation and air conditioning (HVAC) system. Airborne bacteria and fungi were collected in three open-space offices during different seasons. The microbial levels in the outdoor air, supply air diffusers, fan coil air flow and air treatment unit humidification water tank were used to evaluate the influence of the HVAC system on indoor air quality (IAQ). A medium-low level of bacterial contamination (50-500 CFU/m(3)) was found in indoor air. Staphylococcus and Micrococcus were the most commonly found genera, probably due to human presence. A high fungal concentration was measured due to a flood that occurred during the winter. The indoor seasonal distribution of fungal genera was related to the fungal outdoor distribution. Significant seasonal and daily variation in airborne microorganisms was found, underlining a relationship with the frequency of HVAC system switching on/off. The results of this monitoring highlight the role of the HVAC system on IAQ and could be useful to better characterise bacterial and fungal population in the indoor air of office buildings.

  11. Residential indoor air quality guideline : carbon monoxide

    International Nuclear Information System (INIS)

    2010-01-01

    Carbon monoxide (CO) is a tasteless, odourless, and colourless gas that can be produced by both natural and anthropogenic processes, but is most often formed during the incomplete combustion of organic materials. In the indoor environment, CO occurs directly as a result of emissions from indoor sources or as a result of infiltration from outdoor air containing CO. Studies have shown that the use of specific sources can lead to increased concentrations of CO indoors. This residential indoor air quality guideline examined the factors influencing the introduction, dispersion and removal of CO indoors. The health effects of exposure to low and higher concentrations of CO were discussed. Residential maximum exposure limits for CO were presented. Sources and concentrations in indoor environments were also examined. 17 refs., 2 tabs.

  12. Assessment and determinants of airborne bacterial and fungal concentrations in different indoor environments: Homes, child day-care centres, primary schools and elderly care centres

    Science.gov (United States)

    Madureira, Joana; Paciência, Inês; Rufo, João Cavaleiro; Pereira, Cristiana; Teixeira, João Paulo; de Oliveira Fernandes, Eduardo

    2015-05-01

    Until now the influence of risk factors resulting from exposure to biological agents in indoor air has been far less studied than outdoor pollution; therefore the uncertainty of health risks, and how to effectively prevent these, remains. This study aimed (i) to quantify airborne cultivable bacterial and fungal concentrations in four different types of indoor environment as well as to identify the recovered fungi; (ii) to assess the impact of outdoor bacterial and fungal concentrations on indoor air; (iii) to investigate the influence of carbon dioxide (CO2), temperature and relative humidity on bacterial and fungal concentrations; and (iv) to estimate bacterial and fungal dose rate for children (3-5 years old and 8-10 years old) in comparison with the elderly. Air samples were collected in 68 homes, 9 child day-care centres, 20 primary schools and 22 elderly care centres, in a total of 264 rooms with a microbiological air sampler and using tryptic soy agar and malt extract agar culture media for bacteria and fungi growth, respectively. For each building, one outdoor representative location were identified and simultaneously studied. The results showed that child day-care centres were the indoor microenvironment with the highest median bacterial and fungal concentrations (3870 CFU/m3 and 415 CFU/m3, respectively), whereas the lowest median concentrations were observed in elderly care centres (222 CFU/m3 and 180 CFU/m3, respectively). Indoor bacterial concentrations were significantly higher than outdoor concentrations (p < 0.05); whereas the indoor/outdoor ratios for the obtained fungal concentrations were approximately around the unit. Indoor CO2 levels were associated with the bacterial concentration, probably due to occupancy and insufficient ventilation. Penicillium and Cladosporium were the most frequently occurring fungi. Children's had two times higher dose rate to biological pollutants when compared to adult individuals. Thus, due to children

  13. A comparative study on indoor air quality in a low cost and a green ...

    African Journals Online (AJOL)

    user

    A statistical correlation analysis of indoor concentration levels with outdoor concentrations was carried ... New studies around the world on the health effects of air pollution ... benefits at all levels from using green affordable housing practices ...

  14. Design Criteria for Achieving Acceptable Indoor Radon Concentration

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2016-01-01

    Design criteria for achieving an acceptable indoor radon concentration are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization...... in most countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. The first two criteria can prevent radon from infiltrating...... from the ground, and the third criteria can dilute the indoor air. By combining these three criteria, the indoor radon concentration can be lowered achieving an acceptable level. In addition, a cheap and reliable method for measuring the radon concentration in the indoor air is described. The provision...

  15. Indoor Air Pollution

    Science.gov (United States)

    We usually think of air pollution as being outdoors, but the air in your house or office could also be polluted. Sources of indoor pollution include Mold and pollen Tobacco smoke Household products ...

  16. Towards Indoor Transportation Mode Detection using Mobile Sensing

    DEFF Research Database (Denmark)

    Prentow, Thor Siiger; Blunck, Henrik; Kjærgaard, Mikkel Baun

    2015-01-01

    Transportation mode detection is a growing field of research, in which a variety of methods have been developed for detecting transportation modes foremost for outdoor travels. It has been employed in application areas such as public transportation, environmental footprint profiling, and context......-aware mobile assistants. For indoor travels the problem of transportation mode detection has received comparatively little attention, even though diverse transportation modes, such as biking, electric vehicles, and scooters, are used indoors, especially in large building complexes. The potential applications...... are diverse, may also extend beyond indoor variants of the above outdoor applications, and include, e.g., scheduling and progress tracking for mobile workers, management of vehicular resources, and navigation support. However, for indoor transportation mode detection, both the physical environment as well...

  17. The impact of mass transfer limitations on size distributions of particle associated SVOCs in outdoor and indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Cong; Zhang, Yinping [Department of Building Science, Tsinghua University, Beijing (China); Weschler, Charles J., E-mail: weschlch@rwjms.rutgers.edu [Department of Building Science, Tsinghua University, Beijing (China); Environmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, NJ (United States); International Center for Indoor Environment and Energy, Technical University of Denmark, Lyngby (Denmark)

    2014-11-01

    Semi-volatile organic compounds (SVOCs) partition between the gas phase and airborne particles. The size distribution of particle-associated SVOCs impacts their fate in outdoor and indoor environments, as well as human exposure to these compounds and subsequent health risks. Allen et al. (1996) previously proposed that the rate of mass transfer can impact polycyclic aromatic hydrocarbon (PAH) partitioning among different sized particles, especially for time scales relevant to urban aerosols. The present study quantitatively builds on this idea, presenting a model that incorporates dynamic SVOC/particle interaction and applying this model to typical outdoor and indoor scenarios. The model indicates that the impact of mass transfer limitations on the size distribution of a particle-associated SVOC can be evaluated by the ratio of the time to achieve gas–particle equilibrium relative to the residence time of particles. The higher this ratio, the greater the influence of mass transfer limitations on the size distribution of particle-associated SVOCs. The influence of such constraints is largest on the fraction of particle-associated SVOCs in the coarse mode (> 2 μm). Predictions from the model have been found to be in reasonable agreement with size distributions measured for PAHs at roadside and suburban locations in Japan. The model also quantitatively explains shifts in the size distributions of particle associated SVOCs compared to those for particle mass, and the manner in which these shifts vary with temperature and an SVOC's molecular weight. - Highlights: • Rate of mass transfer can impact SVOC partitioning among different sized particles. • Model was developed that incorporates dynamic SVOC/particle sorption. • Key parameters: mass-transfer coefficients, partition coefficient, residence time • Model explains observed SVOC size distribution shifts with temperature and MW. • Largest impact of mass transfer constraints: SVOC sorption to coarse

  18. Air Quality and Indoor Environmental Exposures: Clinical Impacts

    Science.gov (United States)

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more pol...

  19. Development of a model for radon concentration in indoor air

    International Nuclear Information System (INIS)

    Jelle, Bjørn Petter

    2012-01-01

    A model is developed for calculation of the radon concentration in indoor air. The model takes into account various important parameters, e.g. radon concentration in ground, radon diffusion resistance of radon barrier, air permeance of ground, air pressure difference between outdoor ground and indoor at ground level, ventilation of the building ground and number of air changes per hour due to ventilation. Characteristic case studies are depicted in selected 2D and 3D graphical plots for easy visualization and interpretation. The radon transport into buildings might be dominated by diffusion, pressure driven flow or a mixture of both depending on the actual values of the various parameters. The results of our work indicate that with realistic or typical values of the parameters, most of the transport of radon from the building ground to the indoor air is due to air leakage driven by pressure differences through the construction. By incorporation of various and realistic values in the radon model, valuable information about the miscellaneous parameters influencing the indoor radon level is gained. Hence, the presented radon model may be utilized as a simple yet versatile and powerful tool for examining which preventive or remedial measures should be carried out to achieve an indoor radon level below the reference level as set by the authorities. - Highlights: ► Model development for calculation of radon concentration in indoor air. ► Radon model accounting for various important parameters. ► Characteristic case studies depicted in 2D and 3D graphical plots. ► May be utilized for examining radon preventive measures.

  20. Indoor-outdoor particle effects on health in middle-aged and elderly

    DEFF Research Database (Denmark)

    Karottki, Dorina Gabriela; Bekö, Gabriel; Hemmingsen, Jette G.

    2016-01-01

    support detrimental effect of UFP from traffic on vascular function. Indoor UFP and PM2.5 might contribute to cardiovascular risk through endothelial damage and vascular dysfunction, respectively, whereas indoor UFP dominated by candle burning appears to have adverse lung effects. The biomarkers provided...

  1. Indoor air quality in the Karns research houses: baseline measurements and impact of indoor environmental parameters on formaldehyde concentrations

    International Nuclear Information System (INIS)

    Matthews, T.G.; Fung, K.W.; Tromberg, B.J.; Hawthorne, A.R.

    1985-12-01

    Baseline indoor air quality measurements, a nine-month radon study, and an environmental parameters study examining the impact of indoor temperature (T) and relative humidity (RH) levels on formaldehyde (CH 2 O) concentrations have been performed in three unoccupied research homes located in Karns, Tennessee. Inter-house comparison measurements of (1) CH 2 O concentration, (2) CH 2 O emission rates from primary CH 2 O emission sources, (3) radon and radon daughter concentrations, and (4) air exchange rates indicate that the three homes are similar. The results of the nine-month radon study indicate indoor concentrations consistently below the EPA recommended level of 4 pCi/L. Evidence was found that crawl-space concentrations may be reduced using heat pump systems whose outdoor units circulate fresh air through the crawl-space. The modeled results of the environmental parameters study indicate approximate fourfold increases in CH 2 O concentrations from 0.07 to 0.27 ppM for seasonal T and RH conditions of 20 0 C, 30% RH and 29 0 C, 80% RH, respectively. Evaluation of these environmental parameters study data with steady-state CH 2 O concentration models developed from laboratory studies of the environmental dependence of CH 2 O emissions from particleboard underlayment indicate good correlations between the laboratory and field studies

  2. Effectiveness of Indoor Plant to Reduce CO2 in Indoor Environment

    Directory of Open Access Journals (Sweden)

    Suhaimi Mohd Mahathir

    2017-01-01

    Full Text Available Modern country strongly emphasizes on indoor air quality (IAQ because it can effect on human health and productivity. Numerous efforts were performed to make sure that sustainability of IAQ is guaranteed. In the last 4th decade, researchers discover that indoor plants have abilities to reduce indoor air pollution. Generally, plants, carbon dioxide (CO2, light, and temperature involve in the photosynthesis process. This paper intends to study the effectiveness of seven indoor plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium to reduce CO2 with different light level. This study was conducted in one cubic meter of chamber, and each plant was put into the chamber individually with CO2 concentration in the chamber is set at 1000±50ppm, and light intensities is set at 300 and 700 lux, while temperature were fixed at 25±1°C. Based on the results, only the Spider Plant was not able to absorb CO2 during the test at 300 lux of light intensity. Meanwhile, Prayer Plant performed well when tested at 300 or 700 lux of light intensity compare to other investigates plants. This study can conclude that light intensity play an important role for the plant to absorb CO2 effectively. All the indoor plants absorbed more CO2, when the light intensity is increased.

  3. Performance of introducing outdoor cold air for cooling a plant production system with artificial light

    Directory of Open Access Journals (Sweden)

    Jun eWang

    2016-03-01

    Full Text Available The commercial use of a plant production system with artificial light (PPAL is limited by its high initial construction and operation costs. The electric-energy consumed by heat pumps, applied mainly for cooling, accounts for 15-35% of the total electric-energy used in a PPAL. To reduce the electric-energy consumption, an air exchanger with low capacity (180 W was used for cooling by introducing outdoor cold air. In this experiment, the indoor air temperature in two PPALs (floor area: 6.2 m2 each was maintained at 25ºC and 20ºC during light and dark periods, respectively, for lettuce production. In one PPAL (PPALe, an air exchanger (air flow rate: 250 m3 h-1 was used along with a heat pump (cooling capacity: 3.2 kW to maintain the indoor air temperature at the set-point. The other PPAL (PPALc with only a heat pump (cooling capacity: 3.2 kW was used for reference. Effects of introducing outdoor cold air on energy use efficiency, coefficient of performance (COP, electric-energy consumption for cooling and growth of lettuce were investigated. The results show that: when the air temperature difference between indoor and outdoor ranged from 20.2°C to 30.0°C: 1 the average energy use efficiency of the air exchanger was 2.8 and 3.4 times greater than the COP of the heat pumps in the PPALe and PPALc, respectively; 2 hourly electric-energy consumption in the PPALe reduced by 15.8-73.7% compared with that in the PPALc; 3 daily supply of CO2 in the PPALe reduced from 0.15 kg to 0.04 kg compared with that in the PPALc; 4 no significant difference in lettuce growth was observed in both PPALs. The results indicate that using air exchanger to introduce outdoor cold air should be considered as an effective way to reduce electric-energy consumption for cooling with little effects on plant growth in a PPAL.

  4. An architectural framework for 5G indoor communications

    NARCIS (Netherlands)

    Chandra, Kishor; Prasad, R. Venkatesha; Niemegeers, Ignas

    2015-01-01

    In this paper, we emphasize on indoor networks in 5G era. We explore the possible technologies and architectural solutions for 5G indoor communications. Owing to the fact that requirements for indoor and outdoor communications will be quite different in the next generation networks, we try to define

  5. Radon survey in outdoor workplaces of the Tsugaru area

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shun'ichi; Inaba, Jiro

    2000-01-01

    We previously surveyed indoor Rn concentration in homes throughout Aomori Prefecture from 1991 to 1995, and found a mean Rn concentration of 9 Bq m -3 . For accurate evaluation of radiation dose from Rn, its concentration not only in the home but also in workplaces and schools is important, since workers and students spend approximately one-third of the day in these places. Then, we obtained indoor Rn concentrations in several indoor workplaces and schools in Aomori Prefecture. Now, measurements of Rn in outdoor workplaces have been planned for the prefecture during a two-year period. Results for half the prefecture, the Tsugaru area, are described here. Passive Rn detectors using polycarbonate film were employed for long-term monitoring. Diurnal variations of Rn and its daughter nuclides were measured by an active Rn detector with an ionization chamber and a working level meter, respectively. The mean Rn concentration obtained with the passive detectors was approximately 6 Bq m -3 in the outdoor workplaces, and lower than that in the indoor workplaces and school (14 Bq m -3 ). The Rn concentrations for fishing boats and harbors were slightly lower than typical values and some data for forests were higher than other workplaces. The diurnal variations, i.e. higher concentrations at night and lower ones during the day, were observed by the active detectors. (author)

  6. Factors influencing indoor PM2.5 concentration in rural houses of northern China

    Science.gov (United States)

    Zhang, Xueyan; Chen, Bin

    2018-02-01

    In traditional houses in rural areas of Northern China, most traditional heating systems, heated by mini-stove in the kitchen, usually take agricultural residues as fuels resources. Besides, burning cave under the ground-floor of a rural house is also widely used. The higher PM2.5 concentration is crisis for human health. In this study, PM2.5 concentration, temperature, relative humidity inside and outside the houses have been measured, moreover the factors impact on I/O rate coefficient has been discussed. The results show that the I/O rate coefficient in the evening is 2.5 times greater than the I/O rate coefficient in the daytime. I/O rate coefficient of PM2.5 concentration is positive related to air temperature difference between indoor and outdoor. In addition, the impact of outdoor wind speed and predominant wind direction on the PM2.5 emission has been studied.

  7. INDOOR LOCALIZATION USING WI-FI BASED FINGERPRINTING AND TRILATERATION TECHIQUES FOR LBS APPLICATIONS

    Directory of Open Access Journals (Sweden)

    S. Chan

    2012-06-01

    Full Text Available The past few years have seen wide spread adoption of outdoor positioning services, mainly GPS, being incorporated into everyday devices such as smartphones and tablets. While outdoor positioning has been well received by the public, its indoor counterpart has been mostly limited to private use due to its higher costs and complexity for setting up the proper environment. The objective of this research is to provide an affordable mean for indoor localization using wireless local area network (WLAN Wi-Fi technology. We combined two different Wi-Fi approaches to locate a user. The first method involves the use of matching the pre-recorded received signal strength (RSS from nearby access points (AP, to the data transmitted from the user on the fly. This is commonly known as "fingerprint matching". The second approach is a distance-based trilateration approach using three known AP coordinates detected on the user's device to derive the position. The combination of the two steps enhances the accuracy of the user position in an indoor environment allowing location-based services (LBS such as mobile augmented reality (MAR to be deployed more effectively in the indoor environment. The mapping of the RSS map can also prove useful to IT planning personnel for covering locations with no Wi-Fi coverage (ie. dead spots. The experiments presented in this research helps provide a foundation for the integration of indoor with outdoor positioning to create a seamless transition experience for users.

  8. Indoor Localization Using Wi-Fi Based Fingerprinting and Trilateration Techiques for Lbs Applications

    Science.gov (United States)

    Chan, S.; Sohn, G.

    2012-06-01

    The past few years have seen wide spread adoption of outdoor positioning services, mainly GPS, being incorporated into everyday devices such as smartphones and tablets. While outdoor positioning has been well received by the public, its indoor counterpart has been mostly limited to private use due to its higher costs and complexity for setting up the proper environment. The objective of this research is to provide an affordable mean for indoor localization using wireless local area network (WLAN) Wi-Fi technology. We combined two different Wi-Fi approaches to locate a user. The first method involves the use of matching the pre-recorded received signal strength (RSS) from nearby access points (AP), to the data transmitted from the user on the fly. This is commonly known as "fingerprint matching". The second approach is a distance-based trilateration approach using three known AP coordinates detected on the user's device to derive the position. The combination of the two steps enhances the accuracy of the user position in an indoor environment allowing location-based services (LBS) such as mobile augmented reality (MAR) to be deployed more effectively in the indoor environment. The mapping of the RSS map can also prove useful to IT planning personnel for covering locations with no Wi-Fi coverage (ie. dead spots). The experiments presented in this research helps provide a foundation for the integration of indoor with outdoor positioning to create a seamless transition experience for users.

  9. New Directions: Ozone-initiated reaction products indoors may be more harmful than ozone itself

    Science.gov (United States)

    Weschler, Charles J.

    2004-10-01

    Epidemiological studies have found associations between ozone concentrations measured at outdoor monitoring stations and certain adverse health outcomes. As a recent example, Gent et al. (2003, Journal of the American Medical Association 290, 1859-1867) have observed an association between ozone levels and respiratory symptoms as well as the use of maintenance medication by 271 asthmatic children living in Connecticut and the Springfield area of Massachusetts. In another example, Gilliland et al. (2001, Epidemiology 12, 43-54) detected an association between short-term increases in ozone levels and increased absences among 4th grade students from 12 southern California communities during the period from January to June 1996. Although children may spend a significant amount of time outdoors, especially during periods when ozone levels are elevated, they spend a much larger fraction of their time indoors. I hypothesize that exposure to the products of ozone-initiated indoor chemistry is more directly responsible for the health effects observed in the cited epidemiological studies than is exposure to outdoor ozone itself.

  10. Measurements of benzene and formaldehyde in a medium sized urban environment. Indoor/outdoor health risk implications on special population groups.

    Science.gov (United States)

    Pilidis, Georgios A; Karakitsios, Spyros P; Kassomenos, Pavlos A; Kazos, Elias A; Stalikas, Constantine D

    2009-03-01

    In the present study, the results of a measurement campaign aiming to assess cancer risk among two special groups of population: policemen and laboratory technicians exposed to the toxic substances, benzene and formaldehyde are presented. The exposure is compared to general population risk. The results show that policemen working outdoor (traffic regulation, patrol on foot or in vehicles, etc.) are exposed at a significantly higher benzene concentration (3-5 times) than the general population, while the exposure to carbonyls is in general lower. The laboratory technicians appear to be highly exposed to formaldehyde while no significant variation of benzene exposure in comparison to the general population is recorded. The assessment revealed that laboratory technicians and policemen run a 20% and 1% higher cancer risk respectively compared to the general population. Indoor working place air quality is more significant in assessing cancer risk in these two categories of professionals, due to the higher Inhalation Unit Risk (IUR) of formaldehyde compared to benzene. Since the origin of the danger to laboratory technicians is clear (use of chemicals necessary for the experiments), in policemen the presence of carbonyls in indoor air concentrations due to smoking or used materials constitute a danger equal to the exposure to traffic originated air pollutants.

  11. Modeling emission rates and exposures from outdoor cooking

    Science.gov (United States)

    Edwards, Rufus; Princevac, Marko; Weltman, Robert; Ghasemian, Masoud; Arora, Narendra K.; Bond, Tami

    2017-09-01

    Approximately 3 billion individuals rely on solid fuels for cooking globally. For a large portion of these - an estimated 533 million - cooking is outdoors, where emissions from cookstoves pose a health risk to both cooks and other household and village members. Models that estimate emissions rates from stoves in indoor environments that would meet WHO air quality guidelines (AQG), explicitly don't account for outdoor cooking. The objectives of this paper are to link health based exposure guidelines with emissions from outdoor cookstoves, using a Monte Carlo simulation of cooking times from Haryana India coupled with inverse Gaussian dispersion models. Mean emission rates for outdoor cooking that would result in incremental increases in personal exposure equivalent to the WHO AQG during a 24-h period were 126 ± 13 mg/min for cooking while squatting and 99 ± 10 mg/min while standing. Emission rates modeled for outdoor cooking are substantially higher than emission rates for indoor cooking to meet AQG, because the models estimate impact of emissions on personal exposure concentrations rather than microenvironment concentrations, and because the smoke disperses more readily outdoors compared to indoor environments. As a result, many more stoves including the best performing solid-fuel biomass stoves would meet AQG when cooking outdoors, but may also result in substantial localized neighborhood pollution depending on housing density. Inclusion of the neighborhood impact of pollution should be addressed more formally both in guidelines on emissions rates from stoves that would be protective of health, and also in wider health impact evaluation efforts and burden of disease estimates. Emissions guidelines should better represent the different contexts in which stoves are being used, especially because in these contexts the best performing solid fuel stoves have the potential to provide significant benefits.

  12. Efficiency simulations of thin film chalcogenide photovoltaic cells for different indoor lighting conditions

    International Nuclear Information System (INIS)

    Minnaert, B.; Veelaert, P.

    2011-01-01

    Photovoltaic (PV) energy is an efficient natural energy source for outdoor applications. However, for indoor applications, the efficiency of PV cells is much lower. Typically, the light intensity under artificial lighting conditions is less than 10 W/m 2 as compared to 100-1000 W/m 2 under outdoor conditions. Moreover, the spectrum is different from the outdoor solar spectrum. In this context, the question arises whether thin film chalcogenide photovoltaic cells are suitable for indoor use. This paper contributes to answering that question by comparing the power output of different thin film chalcogenide solar cells with the classical crystalline silicon cell as reference. The comparisons are done by efficiency simulation based on the quantum efficiencies of the solar cells and the light spectra of typical artificial light sources i.e. an LED lamp, a 'warm' and a 'cool' fluorescent tube and a common incandescent and halogen lamp, which are compared to the outdoor AM 1.5 spectrum as reference.

  13. A survey on distribution and toxigenicity of Aspergillus flavus from indoor and outdoor hospital environments.

    Science.gov (United States)

    Sepahvand, Asghar; Shams-Ghahfarokhi, Masoomeh; Allameh, Abdolamir; Jahanshiri, Zahra; Jamali, Mojdeh; Razzaghi-Abyaneh, Mehdi

    2011-11-01

    In the present study, genetic diversity and mycotoxin profiles of Aspergillus flavus isolated from air (indoors and outdoors), levels (surfaces), and soils of five hospitals in Southwest Iran were examined. From a total of 146 Aspergillus colonies, 63 isolates were finally identified as A. flavus by a combination of colony morphology, microscopic criteria, and mycotoxin profiles. No Aspergillus parasiticus was isolated from examined samples. Chromatographic analyses of A. flavus isolates cultured on yeast extract-sucrose broth by tip culture method showed that approximately 10% and 45% of the isolates were able to produce aflatoxin B(1) (AFB(1)) and cyclopiazonic acid (CPA), respectively. Around 40% of the isolates produced sclerotia on Czapek-Dox agar. The isolates were classified into four chemotypes based on the ability to produce AF and CPA that majority of them (55.5%) belonged to chemotype IV comprising non-mycotoxigenic isolates. Random amplified polymorphic DNA (RAPD) profiles generated by a combination of four selected primers were used to assess genetic relatedness of 16 selected toxigenic and non-toxigenic isolates. The resulting dendrogram demonstrated the formation of two separate clusters for the A. flavus comprised both mycotoxigenic and non-toxigenic isolates in a random distribution. The obtained results in this study showed that RAPD profiling is a promising and efficient tool to determine intra-specific genetic variation among A. flavus populations from hospital environments. A. flavus isolates, either toxigenic or non-toxigenic, should be considered as potential threats for hospitalized patients due to their obvious role in the etiology of nosocomial aspergillosis.

  14. Indoor environmental health

    CSIR Research Space (South Africa)

    Parsons, S

    2010-01-01

    Full Text Available Indoor Environmental Health (IEH) is a comprehensive term that includes the effects of quantity of air, light and noise in a space and the physical, physiological and psychological aspects from colours, aesthetics, services, outdoor climate...

  15. Indoor environmental health

    CSIR Research Space (South Africa)

    Parsons, SA

    2010-04-01

    Full Text Available Indoor Environmental Health (IEH) is a comprehensive term that includes the effects of quantity of air, light and noise in a space and the physical, physiological and psychological aspects from colours, aesthetics, services, outdoor climate...

  16. Reducing health risks from indoor exposures in rapidly developing urban China.

    Science.gov (United States)

    Zhang, Yinping; Mo, Jinhan; Weschler, Charles J

    2013-07-01

    Over the past two decades there has been a large migration of China's population from rural to urban regions. At the same time, residences in cities have changed in character from single-story or low-rise buildings to high-rise structures constructed and furnished with many synthetic materials. As a consequence, indoor exposures (to pollutants with outdoor and indoor sources) have changed significantly. We briefly discuss the inferred impact that urbanization and modernization have had on indoor exposures and public health in China. We argue that growing adverse health costs associated with these changes are not inevitable, and we present steps that could be taken to reduce indoor exposures to harmful pollutants. As documented by China's Ministry of Health, there have been significant increases in morbidity and mortality among urban residents over the past 20 years. Evidence suggests that the population's exposure to air pollutants has contributed to increases in lung cancer, cardiovascular disease, pulmonary disease, and birth defects. Whether a pollutant has an outdoor or an indoor source, most exposure to the pollutant occurs indoors. Going forward, indoor exposures can be reduced by limiting the ingress of outdoor pollutants (while providing adequate ventilation with clean air), minimizing indoor sources of pollutants, updating government policies related to indoor pollution, and addressing indoor air quality during a building's initial design. Taking the suggested steps could lead to significant reductions in morbidity and mortality, greatly reducing the societal costs associated with pollutant derived ill health.

  17. The effects of an energy efficiency retrofit on indoor air quality.

    Science.gov (United States)

    Frey, S E; Destaillats, H; Cohn, S; Ahrentzen, S; Fraser, M P

    2015-04-01

    To investigate the impacts of an energy efficiency retrofit, indoor air quality and resident health were evaluated at a low-income senior housing apartment complex in Phoenix, Arizona, before and after a green energy building renovation. Indoor and outdoor air quality sampling was carried out simultaneously with a questionnaire to characterize personal habits and general health of residents. Measured indoor formaldehyde levels before the building retrofit routinely exceeded reference exposure limits, but in the long-term follow-up sampling, indoor formaldehyde decreased for the entire study population by a statistically significant margin. Indoor PM levels were dominated by fine particles and showed a statistically significant decrease in the long-term follow-up sampling within certain resident subpopulations (i.e. residents who report smoking and residents who had lived longer at the apartment complex). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Indoor environmental quality in French dwellings and building characteristics

    Science.gov (United States)

    Langer, Sarka; Ramalho, Olivier; Derbez, Mickaël; Ribéron, Jacques; Kirchner, Severine; Mandin, Corinne

    2016-03-01

    A national survey on indoor environmental quality covering 567 residences in mainland France was performed during 2003-2005. The measured parameters were temperature, relative humidity, CO2, and the indoor air pollutants: fourteen individual volatile organic compounds (VOC), four aldehydes and particulate matter PM10 and PM2.5. The measured indoor concentrations were analyzed for correlations with the building characteristics: type of dwelling, period of construction, dwelling location, type of ventilation system, building material, attached garage and retrofitting. The median night time air exchange rate (AER) for all dwellings was 0.44 h-1. The night time AER was higher in apartments (median = 0.49 h-1) than in single-family houses (median = 0.41 h-1). Concentration of formaldehyde was approximately 30% higher in dwellings built after 1990 compared with older ones; it was higher in dwellings with mechanical ventilation and in concrete buildings. The VOC concentrations depended on the building characteristics to various extents. The sampling season influenced the majority of the indoor climate parameters and the concentrations of the air pollutants to a higher degree than the building characteristics. Multivariate linear regression models revealed that the indoor-outdoor difference in specific humidity, a proxy for number of occupants and their indoor activities, remained a significant predictor for most gaseous and particulate air pollutants. The other strong predictors were outdoor concentration, smoking, attached garage and AER (in descending order).

  19. Distribution of indoor radon levels in Mexico

    CERN Document Server

    Espinosa, G; Rickards, J; Gammage, R B

    1999-01-01

    Our laboratory has carried out a systematic monitoring and evaluation of indoor radon concentration levels in Mexico for ten years. The results of the distribution of indoor radon levels for practically the entire country are presented, together with information on geological characteristics, population density, socioeconomic levels of the population, and architectural styles of housing. The measurements of the radon levels were made using the passive method of nuclear tracks in solids with the end-cup system. CR-39 was used as the detector material in combination with a one-step chemical etching procedure and an automatic digital- image counting system. Wherever a high level was measured, a confirming measurement was made using a dynamic method. The results are important for future health studies, including the eventual establishment of patterns for indoor radon concentration, as it has been done in the USA and Europe.

  20. Reduction in NO2-concentration across ventilation filters in an office building located close to heavy traffic

    OpenAIRE

    Reyes-Lingjerde, Alexander

    2016-01-01

    In Scandinavia, people live in climatic conditions that makes it favorable to stay indoors at wintertime. Norway has a relatively small population, even so Bergen and Oslo reaches annual average nitrogen dioxide concentrations equal to or above the levels in large European cities. Newspapers in Bergen recommend the population to stay indoors in urban areas that are highly polluted. Bergen municipality takes measurements of the outdoor pollution continuously, but mor...

  1. Method, system and apparatus for monitoring and adjusting the quality of indoor air

    Science.gov (United States)

    Hartenstein, Steven D.; Tremblay, Paul L.; Fryer, Michael O.; Hohorst, Frederick A.

    2004-03-23

    A system, method and apparatus is provided for monitoring and adjusting the quality of indoor air. A sensor array senses an air sample from the indoor air and analyzes the air sample to obtain signatures representative of contaminants in the air sample. When the level or type of contaminant poses a threat or hazard to the occupants, the present invention takes corrective actions which may include introducing additional fresh air. The corrective actions taken are intended to promote overall health of personnel, prevent personnel from being overexposed to hazardous contaminants and minimize the cost of operating the HVAC system. The identification of the contaminants is performed by comparing the signatures provided by the sensor array with a database of known signatures. Upon identification, the system takes corrective actions based on the level of contaminant present. The present invention is capable of learning the identity of previously unknown contaminants, which increases its ability to identify contaminants in the future. Indoor air quality is assured by monitoring the contaminants not only in the indoor air, but also in the outdoor air and the air which is to be recirculated. The present invention is easily adaptable to new and existing HVAC systems. In sum, the present invention is able to monitor and adjust the quality of indoor air in real time by sensing the level and type of contaminants present in indoor air, outdoor and recirculated air, providing an intelligent decision about the quality of the air, and minimizing the cost of operating an HVAC system.

  2. Play Equipment, Physical Activity Opportunities, and Children's Activity Levels at Childcare

    Directory of Open Access Journals (Sweden)

    Jessica S. Gubbels

    2012-01-01

    Full Text Available This study investigated the association between physical activity facilities at childcare (e.g., play equipment and physical activity of 2- and 3-year olds. Observations of physical activity intensity were performed among 175 children at 9 childcare centers in The Netherlands, using the OSRAC-P. The physical activity facilities were assessed for indoors and outdoors separately, using the EPAO instrument. Regular (single-level multivariate and multilevel linear regression analyses examined the association of the facilities and child characteristics (age and sex with children's activity levels. Various physical activity facilities were available in all childcare centers (e.g., balls. Riding toys and a small playing area were associated with lower indoor physical activity levels. Outdoor physical activity levels were positively associated with the availability of portable jumping equipment and the presence of a structured track on the playground. Portable slides, fixed swinging equipment, and sandboxes were negatively associated with outdoor activity levels. In addition, the 3-year old children were more active outdoors than the 2-year olds. In conclusion, not all physical activity facilities at childcare were indeed positively associated with children's activity levels. The current findings provide concrete leads for childcare providers regarding which factors they can improve in the physical environment to facilitate children's physical activity.

  3. Over 2 Years of Outdoor Operational and Storage Stability of ITO-free, Fully Roll-to-Roll Fabricated Polymer Solar Cell Modules

    DEFF Research Database (Denmark)

    Angmo, Dechan; Krebs, Frederik C

    2015-01-01

    We report on the stability of large-area (100 cm2), low-cost, indium-tin-oxide (ITO)-free modules over two years (>17 500 h) under outdoor operational conditions in Denmark and under indoor storage condition by following ISOS-O-3 and ISOS-D-2 protocols. Irrespective of the testing regimes (storage...

  4. Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China

    Directory of Open Access Journals (Sweden)

    Zhen Peng

    2017-07-01

    Full Text Available Over 70% of a pupil’s school life is spent inside a classroom, and indoor air quality has a significant impact on students’ attendance and learning potential. Therefore, the indoor air quality in primary school buildings is highly important. This empirical study investigates the indoor air quality in four naturally ventilated schools in China, with a focus on four parameters: PM2.5, PM10, CO2, and temperature. The correlations between the indoor air quality and the ambient air pollution, building defects, and occupants’ activities have been identified and discussed. The results indicate that building defects and occupants’ activities have a significant impact on indoor air quality. Buildings with better air tightness have a relatively smaller ratio of indoor particulate matter (PM concentrations to outdoor PM concentrations when unoccupied. During occupied periods, the indoor/outdoor (I/O ratio could be larger than 1 due to internal students’ activities. The indoor air temperature in winter is mainly determined by occupants’ activities and the adiabatic ability of a building’s fabrics. CO2 can easily exceed 1000 ppm on average due to the closing of windows and doors to keep the inside air warmer in winter. It is concluded that improving air tightness might be a way of reducing outdoor air pollutants’ penetration in naturally ventilated school buildings. Mechanical ventilation with air purification could be also an option on severely polluted days.

  5. Evaluation of the Impact of Indoor Smoking Bans on Air Quality in Australian Licensed Clubs

    Science.gov (United States)

    Davidson, Margaret Elissa

    .5 particulates with a special calibration factor for environmental tobacco smoke calibration factor of 0.32 (PM2.5 (0.32)) was undertaken in the second group of clubs and monthly monitoring following the bans was undertaken in Clubs 9 and 11. There was a significant reduction in the mean airborne concentrations of PM2.5, PM1.0, PM2.5 (0.32), PPAH, CO and nicotine at all clubs following the implementation of the smoking bans. Of note was the increase in the mean outdoor PM2.5 concentrations at 6 clubs, and the significant increase in the number of outdoor smokers at 8 venues. The greatest change was an increase in the frequency of outdoor PM2.5 concentrations exceeding 25 mum m-3 which is the Australian PM2.5 advisory standard for ambient air (24 hours). Weak to strong significant correlations (R2=0.402-0.757 p=0.000-0.022) were identified between outdoor smokers and indoor PM2.5 concentrations (3 clubs), and a significant correlation (R2=1.000 p=0.000) between nicotine and indoor pollutants at one club. The results of this study indicate that indoor smoking bans may not fully protect the health of the public and workers in venues because of the possible infiltration of environmental tobacco smoke (ETS) identified at three clubs, as well as outdoor exposure to ETS associated with an increase in smoking activity. The lack of current indoor air quality standards makes the interpretation of the post ban air quality data difficult. Although, the mean concentration of contaminants were all below recommended limits for ambient air. The potential infiltration of ETS inside some clubs indicates that air quality may still represent both an occupational and public health risk because ETS has no safe exposure limit (WHO, 2000). (Abstract shortened by ProQuest.).

  6. A Hybrid 3D Indoor Space Model

    Directory of Open Access Journals (Sweden)

    A. Jamali

    2016-10-01

    Full Text Available GIS integrates spatial information and spatial analysis. An important example of such integration is for emergency response which requires route planning inside and outside of a building. Route planning requires detailed information related to indoor and outdoor environment. Indoor navigation network models including Geometric Network Model (GNM, Navigable Space Model, sub-division model and regular-grid model lack indoor data sources and abstraction methods. In this paper, a hybrid indoor space model is proposed. In the proposed method, 3D modeling of indoor navigation network is based on surveying control points and it is less dependent on the 3D geometrical building model. This research proposes a method of indoor space modeling for the buildings which do not have proper 2D/3D geometrical models or they lack semantic or topological information. The proposed hybrid model consists of topological, geometrical and semantical space.

  7. Enhancing indoor air quality -The air filter advantage.

    Science.gov (United States)

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality.

  8. Indoor tetrachloroethylene levels and determinants in Paris dwellings.

    Science.gov (United States)

    Roda, Célina; Kousignian, Isabelle; Ramond, Anna; Momas, Isabelle

    2013-01-01

    There is growing public health concern about indoor air quality. Tetrachloroethylene (PERC), a chlorinated volatile organic compound widely used as a solvent in dry cleaning facilities, can be a residential indoor air pollutant. As part of an environmental investigation included in the PARIS (Pollution and asthma Risk: an Infant Study) birth cohort, this study firstly aimed to document domestic PERC levels, and then to identify the factors influencing these levels using standardized questionnaires about housing characteristics and living conditions. Air samples were collected in the child's bedroom over one week using passive devices when infants were 1, 6, 9, and 12 months. PERC was identified and quantified by gas chromatography/mass spectrometry. PERC annual domestic level was calculated by averaging seasonal levels. PERC was omnipresent indoors, annual levels ranged from 0.6 to 124.2 μg/m3. Multivariate linear and logistic regression models showed that proximity to dry cleaning facilities, do-it-yourself activities (e.g.: photographic development, silverware), presence of air vents, and building construction date (<1945) were responsible for higher domestic levels of PERC. This study, conducted in an urban context, provides helpful information on PERC contamination in dwellings, and identifies parameters influencing this contamination. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air

    Directory of Open Access Journals (Sweden)

    Bartosz Szulczyński

    2017-03-01

    Full Text Available The paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric, photoionization and semiconductor with solid electrolyte ones. Commercially available sensors for detection of VOCs and their metrological parameters—measurement range, limit of detection, measurement resolution, sensitivity and response time—were presented. Moreover, development trends and prospects of improvement of the metrological parameters of these sensors were highlighted.

  10. The identification of Volatile Organic Compound's emission sources in indoor air of living spaces, offices and laboratories

    Science.gov (United States)

    Kultys, Beata

    2018-01-01

    Indoor air quality is important because people spend most of their time in closed rooms. If volatile organic compounds (VOCs) are present at elevated concentrations, they may cause a deterioration in human well-being or health. The identification of indoor emission sources is carried out by comparison indoor and outdoor air composition. The aim of the study was to determinate the concentration of VOCs in indoor air, where there was a risk of elevated levels due to the kind of work type carried out or the users complained about the symptoms of a sick building followed by an appropriate interpretation of the results to determine whether the source of the emission in the tested room occurs. The air from residential, office and laboratory was tested in this study. The identification of emission sources was based on comparison of indoor and outdoor VOCs concentration and their correlation coefficients. The concentration of VOCs in all the rooms were higher or at a similar level to that of the air sampled at the same time outside the building. Human activity, in particular repair works and experiments with organic solvents, has the greatest impact on deterioration of air quality.

  11. Effects of ERV Filter Degradation on Indoor CO2 Levels of a Classroom

    Directory of Open Access Journals (Sweden)

    Jae-Sol Choi

    2018-04-01

    Full Text Available Energy recovery ventilators (ERVs are widely used to reduce energy losses caused by ventilation and improve indoor air quality for recently-constructed buildings. It is important for spaces with high occupancy density and longer residence times, such as classrooms. In classrooms, the ERV size is typically estimated by the target number of students in the design phase, but the design air volume flow rates (m3/h of the ERV can decrease over time owing to filter degradation such as increased dust loading. In this study, field tests are conducted in a classroom to investigate filter degradation through a visual inspection and by measuring the air volume flow rates at the diffusers connected to the ERV. In addition, variations in carbon dioxide (CO2 concentrations are also measured to verify the effects of filter degradation on the indoor CO2 levels over the entire test period, which includes filter replacement, as well. As the tests are conducted during classes, several adjusting methodologies are proposed to match the different test conditions. The results show that the total air volume flow rate of the ERV increases after the filter replacement (546 to 766 m3/h, but it again decreases as time elapses (659 m3/h. Accordingly, the indoor CO2 concentration decreases after the filter replacement by more than 300 ppm (1404 to 1085 ppm, clearly showing the effect of filter degradation. However, this CO2 concentration remains similar for four months after the replacement, and the total air volume rate decreases again. An interpretation is made using computational fluid dynamics analysis that the measured CO2 concentrations are affected by airflow patterns. The airflow in the cooling system may dilute CO2 concentrations at the measuring location. Thus, periodic filter replacement and management are important to ensure the desired ERV air volume rates and consequently the desired indoor CO2 concentrations.

  12. Convenient methods for appreciating effects of acid rain on stone building materials; Sekizai ni taisuru sanseiu no eikyo hyokaho no kento

    Energy Technology Data Exchange (ETDEWEB)

    Katami, T.; Takahara, Y.; Nishikawa, H.; Kato, K. [Gifu Prefectural Health and Environmental Research Center, Gifu (Japan)

    1996-05-10

    A method to evaluate effects of acid rain has been investigated by exposing building marble plates at both outdoor and indoor sites and measuring lightness and roughness on the surface of plates. The lower pH of rain water fell, the more remarkable loss of lightness appeared in a short period on the surface of outdoor samples in one to three months exposure tests. As an appropriate negative correlation was shown between the lightness and the pH value, it was found that physical change of the plate surface can be estimated by using the lightness, optically measured value. For three to nine months indoor-exposure tests, difference of the lightness were quantitatively observed, but little differences of the roughness height were recognized among the different exposure sites. From the reduction of lightness on the marble plate surface exposed at outdoor and indoor sites, it was also found that damage levels of the marble plates were four to eleven times higher at outdoor sites by rain water than those at indoor sites by air pollutants, such as acid gases, in the ambient air. Thus, the optical method may be useful to evaluate damage levels of marble building materials caused by acid-rain water after exposing them for a relatively short period. 10 refs., 3 figs., 6 tabs.

  13. Rush-hour aromatic and chlorinated hydrocarbons in selected subway stations of Shanghai, China.

    Science.gov (United States)

    Zhang, Yanli; Li, Chunlei; Wang, Xinming; Guo, Hai; Feng, Yanli; Chen, Jianmin

    2012-01-01

    Air samples were collected simultaneously at platform, mezzanine and outdoor in five typical stations of subway system in Shanghai, China using stainless steel canisters and analyzed by gas chromatography-mass selective detector (GC-MSD) after cryogenic preconcentration. Benzene, toluene, ethylbenzene and xylenes (BTEX) at the platforms and mezzanines inside the stations averaged (10.3 +/- 2.1), (38.7 +/- 9.0), (19.4 +/- 10.1) and (30.0 +/- 11.1) microg/m3, respectively; while trichloroethylene (TrCE), tetrachloroethylene (TeCE) and para-dichlorobenzene (pDCB), vinyl chloride and carbon tetrachloride were the most abundant chlorinated hydrocarbons inside the stations with average levels of (3.6 +/- 1.3), (1.3 +/- 0.5), (4.1 +/- 1.1), (2.2 +/- 1.1) and (1.2 +/- 0.3) microg/m3, respectively. Mean levels of major aromatic and chlorinated hydrocarbons were higher indoor (platforms and mezzanines) than outdoor with average indoor/outdoor (I/O) ratios of 1.1-9.5, whereas no significant indoor/outdoor differences were found except for benzene and TrCE. The highly significant mutual correlations (p subway stations from indoor/outdoor air exchange and traffic emission should be their dominant source. TrCE and pDCB were mainly from indoor emission and TeCE might have both indoor emission sources and contribution from outdoor air, especially in the mezzanines.

  14. Understanding the origin of radon indoors: Building a predictive capability

    International Nuclear Information System (INIS)

    Sextro, R.G.

    1985-12-01

    Indoor radon concentrations one to two orders of magnitude higher than the US average of ∼60 Bq m -3 (∼1.5 pCi L -1 ) are not uncommon, and concentrations greater than 4000 Bq m -3 have been observed in houses in areas with no known artificially-enhanced radon sources. In general, source categories for indoor radon are well known: soil, domestic water, building materials, outdoor air, and natural gas. Soil is thought to be a major source of indoor radon, either through molecular diffusion (usually a minor component) or convective flow of soil gas. While soil gas flow into residences has been demonstrated, no detailed understanding of the important factors affecting the source strength of radon from soil has yet emerged. Preliminary work in this area has identified a number of likely issues, including the concentration of radium in the soil, the emanating fraction, soil type, soil moisture content, and other factors that would influence soil permeability and soil gas transport. Because a significant number of dwellings are expected to have indoor radon concentrations above guideline levels, a predictive capability is needed that would help identify geographical areas having the potential for high indoor concentrations. This paper reviews the preliminary work that has been done to identify important soil and building characteristics that influence the migration of radon and outlines the areas of further research necessary for development of a predictive method. 32 refs., 4 figs

  15. Invited Article: Channel performance for indoor and outdoor terahertz wireless links

    Science.gov (United States)

    Ma, Jianjun; Shrestha, Rabi; Moeller, Lothar; Mittleman, Daniel M.

    2018-05-01

    One of the most exciting future applications of terahertz technology is in the area of wireless communications. As 5G systems incorporating a standard for millimeter-wave wireless links approach commercial roll-out, it is becoming clear that even this new infrastructure will not be sufficient to keep pace with the rapidly increasing global demand for bandwidth. One favorable solution that is attracting increasing attention for subsequent generations of wireless technology is to use higher frequencies, above 100 GHz. The implementation of such links will require significant advances in hardware, algorithms, and architecture. Although numerous research groups are exploring aspects of this challenging problem, many basic questions remain unaddressed. Here, we present an experimental effort to characterize THz wireless links in both indoor and outdoor environments. We report measurements at 100, 200, 300, and 400 GHz, using a link with a data rate of 1 Gbit/s. We demonstrate both line-of-sight and non-line-of-sight (specular reflection) links off of interior building walls. This work represents a first step to establish the feasibility of using THz carrier waves for data transmission in diverse situations and environments.

  16. Household wood heater usage and indoor leakage of BTEX in Launceston, Australia: A null result

    Science.gov (United States)

    Galbally, Ian E.; Gillett, Robert W.; Powell, Jennifer C.; Lawson, Sarah J.; Bentley, Simon T.; Weeks, Ian A.

    A study has been conducted in Launceston, Australia, to determine within households with wood heaters the effect of leakage from the heater and flue on the indoor air concentrations of the pollutants: benzene, toluene, ethylbenzene and xylene (BTEX). The study involved three classes: 28 households without wood heaters, 19 households with wood heaters compliant with the relevant Australian Standard and 30 households with non-compliant wood heaters. Outdoor and indoor BTEX concentrations were measured in each household for 7 days during summer when there was little or no wood heater usage, and for 7 days during winter when there was widespread wood heater usage. Each participant kept a household activity diary throughout their sampling periods. For wintertime, there were no significant differences of the indoor BTEX concentrations between the three classes of households. Also there were no significant relationships between BTEX indoor concentrations within houses and several measures of the amount of wood heater use within these houses. For the households sampled in this study, the use of a wood heater within a house did not lead to BTEX release within that house and had no direct detectable influence on the concentrations of BTEX within the house. We propose that the pressure differences associated with the both the leakiness or permeability of the building envelope and the draught of the wood heater have key roles in determining whether there will be backflow of smoke from the wood heater into the house. For a leaky house with a well maintained wood heater there should be no backflow of smoke from the wood heater into the house. However backflow of smoke may occur in well sealed houses. The study also found that wood heater emissions raise the outdoor concentrations of BTEX in winter in Launceston and through the mixing of outdoor air through the building envelopes into the houses, these emissions contribute to increases in the indoor concentrations of BTEX in

  17. Outdoor fine and ultrafine particle measurements at six bus stops with smoking on two California arterial highways--results of a pilot study.

    Science.gov (United States)

    Ott, Wayne R; Acevedo-Bolton, Viviana; Cheng, Kai-Chung; Jiang, Ruo-Ting; Klepeis, Neil E; Hildemann, Lynn M

    2014-01-01

    As indoor smoking bans have become widely adopted, some U.S. communities are considering restricting smoking outdoors, creating a need for measurements of air pollution near smokers outdoors. Personal exposure experiments were conducted with four to five participants at six sidewalk bus stops located 1.5-3.3 m from the curb of two heavily traveled California arterial highways with 3300-5100 vehicles per hour. At each bus stop, a smoker in the group smoked a cigarette. Gravimetrically calibrated continuous monitors were used to measure fine particle concentrations (aerodynamic diameter bus stop, ultrafine particles (UFP), wind speed, temperature, relative humidity, and traffic counts were also measured. For 13 cigarette experiments, the mean PM2.5 personal exposure of the nonsmoker seated 0.5 m from the smoker during a 5-min cigarette ranged from 15 to 153 microg/m3. Of four persons seated on the bench, the smoker received the highest PM2.5 breathing-zone exposure of 192 microg/m3. There was a strong proximity effect: nonsmokers at distances 0.5, 1.0, and 1.5 m from the smoker received mean PM2.5 personal exposures of 59, 40, and 28 microg/m3, respectively, compared with a background level of 1.7 microg/m3. Like the PM2.5 concentrations, UFP concentrations measured 0.5 m from the smoker increased abruptly when a cigarette started and decreased when the cigarette ended, averaging 44,500 particles/cm3 compared with the background level of 7200 particles/cm3. During nonsmoking periods, the UFP background concentrations showed occasional peaks due to traffic, whereas PM2.5 background concentrations were extremely low. The results indicate that a single cigarette smoked outdoors at a bus stop can cause PM2.5 and UFP concentrations near the smoker that are 16-35 and 6.2 times, respectively, higher than the background concentrations due to cars and trucks on an adjacent arterial highway. Rules banning smoking indoors have been widely adopted in the United States and in

  18. Optimization of heat pump system in indoor swimming pool using particle swarm algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Wen-Shing; Kung, Chung-Kuan [Department of Energy and Refrigerating Air-Conditioning Engineering, National Taipei University of Technology, 1, Section 3, Chung-Hsiao East Road, Taipei (China)

    2008-09-15

    When it comes to indoor swimming pool facilities, a large amount of energy is required to heat up low-temperature outdoor air before it is being introduced indoors to maintain indoor humidity. Since water is evaporated from the pool surface, the exhausted air contains more water and specific enthalpy. In response to this indoor air, heat pump is generally used in heat recovery for indoor swimming pools. To reduce the cost in energy consumption, this paper utilizes particle swarm algorithm to optimize the design of heat pump system. The optimized parameters include continuous parameters and discrete parameters. The former consists of outdoor air mass flow and heat conductance of heat exchangers; the latter comprises compressor type and boiler type. In a case study, life cycle energy cost is considered as an objective function. In this regard, the optimized outdoor air flow and the optimized design for heating system can be deduced by using particle swarm algorithm. (author)

  19. Outdoor stocking density in free-range laying hens: effects on behaviour and welfare.

    Science.gov (United States)

    Campbell, D L M; Hinch, G N; Downing, J A; Lee, C

    2017-06-01

    Free-range laying hen systems are increasing within Australia and research is needed to determine optimal outdoor stocking densities. Six small (n=150 hens) experimental flocks of ISA Brown laying hens were housed with access to ranges simulating one of three outdoor stocking densities with two pen replicates per density: 2000 hens/ha, 10 000 hens/ha or 20 000 hens/ha. Birds were provided daily range access from 21 to 36 weeks of age and the range usage of 50% of hens was tracked using radio-frequency identification technology. Throughout the study, basic external health assessments following a modified version of the Welfare Quality® protocol showed most birds were in visibly good condition (although keel damage was increasingly present with age) with few differences between stocking densities. Toenail length at 36 weeks of age was negatively correlated with hours spent ranging for all pens of birds (all r⩾-0.23, P⩽0.04). At 23 weeks of age, there were no differences between outdoor stocking densities in albumen corticosterone concentrations (P=0.44). At 35 weeks of age, density effects were significant (Prange and indoors showed more dust bathing and foraging (scratching followed by ground-pecking) was performed outdoors, but more resting indoors (all Prange but the most resting outdoors, with hens from the 20 000 hens/ha densities showing the least amount of resting outdoors (all Pfree-range system management practices.

  20. Annoyance Caused by Noise and Air Pollution during Pregnancy: Associated Factors and Correlation with Outdoor NO2 and Benzene Estimations.

    Science.gov (United States)

    Fernández-Somoano, Ana; Llop, Sabrina; Aguilera, Inmaculada; Tamayo-Uria, Ibon; Martínez, María Dolores; Foraster, Maria; Ballester, Ferran; Tardón, Adonina

    2015-06-18

    This study aimed to describe the degree of annoyance among pregnant women in a Spanish cohort and to examine associations with proximity to traffic, NO2 and benzene exposure. We included 2457 participants from the Spanish Childhood and Environment study. Individual exposures to outdoor NO2 and benzene were estimated, temporally adjusted for pregnancy. Interviews about sociodemographic variables, noise and air pollution were carried out. Levels of annoyance were assessed using a scale from 0 (none) to 10 (strong and unbearable); a level of 8 to 10 was considered high. The reported prevalence of high annoyance levels from air pollution was 11.2% and 15.0% from noise; the two variables were moderately correlated (0.606). Significant correlations between NO2 and annoyance from air pollution (0.154) and that from noise (0.181) were observed. Annoyance owing to noise and air pollution had a low prevalence in our Spanish population compared with other European populations. Both factors were associated with proximity to traffic. In multivariate models, annoyance from air pollution was related to NO2, building age, and country of birth; annoyance from noise was only related to the first two. The health burden of these exposures can be increased by stress caused by the perception of pollution sources.

  1. Indoor aerosol modeling for assessment of exposure and respiratory tract deposited dose

    Science.gov (United States)

    Hussein, Tareq; Wierzbicka, Aneta; Löndahl, Jakob; Lazaridis, Mihalis; Hänninen, Otto

    2015-04-01

    Air pollution is one of the major environmental problems that influence people's health. Exposure to harmful particulate matter (PM) occurs both outdoors and indoors, but while people spend most of their time indoors, the indoor exposures tend to dominate. Moreover, higher PM concentrations due to indoor sources and tightness of indoor environments may substantially add to the outdoor originating exposures. Empirical and real-time assessment of human exposure is often impossible; therefore, indoor aerosol modeling (IAM) can be used as a superior method in exposure and health effects studies. This paper presents a simple approach in combining available aerosol-based modeling techniques to evaluate the real-time exposure and respiratory tract deposited dose based on particle size. Our simple approach consists of outdoor aerosol data base, IAM simulations, time-activity pattern data-base, physical-chemical properties of inhaled aerosols, and semi-empirical deposition fraction of aerosols in the respiratory tract. These modeling techniques allow the characterization of regional deposited dose in any metric: particle mass, particle number, and surface area. The first part of this presentation reviews recent advances in simple mass-balance based modeling methods that are needed in analyzing the health relevance of indoor exposures. The second part illustrates the use of IAM in the calculations of exposure and deposited dose. Contrary to previous methods, the approach presented is a real-time approach and it goes beyond the exposure assessment to provide the required information for the health risk assessment, which is the respiratory tract deposited dose. This simplified approach is foreseen to support epidemiological studies focusing on exposures originating from both indoor and outdoor sources.

  2. Determinants of perceived air pollution annoyance and association between annoyance scores and air pollution (PM 2.5, NO 2) concentrations in the European EXPOLIS study

    Science.gov (United States)

    Rotko, Tuulia; Oglesby, Lucy; Künzli, Nino; Carrer, Paolo; Nieuwenhuijsen, Mark J.; Jantunen, Matti

    Apart from its traditionally considered objective impacts on health, air pollution can also have perceived effects, such as annoyance. The psychological effects of air pollution may often be more important to well-being than the biophysical effects. Health effects of perceived annoyance from air pollution are so far unknown. More knowledge of air pollution annoyance levels, determinants and also associations with different air pollution components is needed. In the European air pollution exposure study, EXPOLIS, the air pollution annoyance as perceived at home, workplace and in traffic were surveyed among other study objectives. Overall 1736 randomly drawn 25-55-yr-old subjects participated in six cities (Athens, Basel, Milan, Oxford, Prague and Helsinki). Levels and predictors of individual perceived annoyances from air pollution were assessed. Instead of the usual air pollution concentrations at fixed monitoring sites, this paper compares the measured microenvironment concentrations and personal exposures of PM 2.5 and NO 2 to the perceived annoyance levels. A considerable proportion of the adults surveyed was annoyed by air pollution. Female gender, self-reported respiratory symptoms, downtown living and self-reported sensitivity to air pollution were directly associated with high air pollution annoyance score while in traffic, but smoking status, age or education level were not significantly associated. Population level annoyance averages correlated with the city average exposure levels of PM 2.5 and NO 2. A high correlation was observed between the personal 48-h PM 2.5 exposure and perceived annoyance at home as well as between the mean annoyance at work and both the average work indoor PM 2.5 and the personal work time PM 2.5 exposure. With the other significant determinants (gender, city code, home location) and home outdoor levels the model explained 14% (PM 2.5) and 19% (NO 2) of the variation in perceived air pollution annoyance in traffic. Compared to

  3. Indoor and ambient air concentrations of respirable particles between two hospitals in Kashan (2014-2015

    Directory of Open Access Journals (Sweden)

    Mahmoud Mohammadyan

    2017-04-01

    Full Text Available Background: The hospital environment requires special attention to provide healthful indoor air quality for protecting patients and healthcare workers against the occupational diseases. The aim of this study was to determine the concentrations of respirable particles indoor and ambient air of two hospitals in Kashan. Materials and Method: This cross-sectional study was conducted during 3 months (Marth 2014 to May 2015. Indoor and outdoor PM10 and PM2.5 concentrations were measured four times a week in the operating room, pediatric and ICU2 (Intensive Care Unit wards using a real time dust monitor at two hospitals. A total number of 480 samples (80 samples indoors and 40 outdoors from wards were collected. Results: The highest mean PM2.5 and PM10 for indoors were determined 57.61± 68.57 µg m-3 and 212.36±295.49 µg m-3, respectively. The results showed a significant relationship between PM2.5 and PM10 in the indoor and ambient air of two hospitals (P<0.05. PM2.5 and PM10 concentrations were different in all of the selected wards (P<0.05. Conclusion: The respirable particle concentrations in the indoor and ambient air in both hospitals were higher than the 24-hours WHO and US-EPA standards. Thence, utilizing sufficient and efficient air conditioning systems in hospitals can be useful in improving indoor air quality and reducing the respirable particle concentrations.

  4. Indoor air quality of environments used for physical exercise and sports practice: Systematic review.

    Science.gov (United States)

    Andrade, Alexandro; Dominski, Fábio Hech

    2018-01-15

    Systematic reviews have the potential to contribute substantially to environmental health and risk assessment. This study aimed to investigate indoor air quality of environments used for physical exercise and sports practice through a systematic review. The systematic review followed the PRISMA guidelines and was recorded in the PROSPERO registry (CRD42016036057). The search was performed using the SciELO, Science Direct, Scopus, LILACS, MEDLINE via PubMed, and SPORTDiscus databases, from their inception through April 2017. The search terms used in the databases were {air pollution" OR "air pollutants" OR "air quality"} AND {"physical exercise" OR "physical activity" OR "sport"}. The results of selected studies were divided into 5 categories for analysis: monitoring of air quality in the environment according to international guidelines, indoor-to-outdoor ratio (I/O), air quality during physical exercise, impact of air quality on health, and interventions to improve indoor air quality. Among 1281 studies screened, 34 satisfied the inclusion criteria. The monitoring of pollutants was conducted in 20 studies. CO and NO 2 were the most investigated pollutants, and guidelines were discussed in most studies. The I/O ratio was investigated in 12 studies, of which 9 showed a higher concentration of some pollutants in indoor rather than outdoor environments. Among the 34 studies selected, only 7 investigated the impact of indoor air pollution on human health. The population in most of these studies consisted of hockey players. Most studies conducted monitoring of pollutants in indoor environments used for physical exercise and sports practice. The earliest studies were conducted in ice skating rinks and the most recent evaluated gymnasiums, fitness centers, and sports centers. The CO, particulate matter, and NO 2 concentrations were the most investigated and have the longest history of investigation. These pollutants were within the limits established by guidelines in most

  5. Healthy environment--indoor air quality of Brazilian elementary schools nearby petrochemical industry.

    Science.gov (United States)

    Godoi, Ricardo H M; Godoi, Ana F L; Gonçalves Junior, Sérgio J; Paralovo, Sarah L; Borillo, Guilherme C; Gonçalves Gregório Barbosa, Cybelli; Arantes, Manoela G; Charello, Renata C; Rosário Filho, Nelson A; Grassi, Marco T; Yamamoto, Carlos I; Potgieter-Vermaak, Sanja; Rotondo, Giuliana G; De Wael, Karolien; van Grieken, Rene

    2013-10-01

    The mitigation of pollution released to the environment originating from the industrial sector has been the aim of all policy-makers and its importance is evident if the adverse health effects on the world population are considered. Although this concern is controversial, petroleum refinery has been linked to some adverse health effects for people living nearby. Apart from home, school is the most important indoor environment for children and there is increasing concern about the school environment and its impact on health, also in developing countries where the prevalence of pollution is higher. As most of the children spend more than 40% of their time in schools, it is critical to evaluate the pollution level in such environment. In the metropolitan region of Curitiba, South Brazil, five schools nearby industries and highways with high density traffic, were selected to characterize the aerosol and gaseous compounds indoor and outdoor of the classrooms, during 2009-2011. Size segregated aerosol samples were collected for analyses of bulk and single particle elemental profiles. They were analyzed by electron probe X-ray micro-analysis (EPXMA), and by energy-dispersive X-ray fluorescence (EDXRF), to investigate the elemental composition of individual particles and bulk samples. The concentrations of benzene, toluene, ethylbenzene, and xylene (BTEX); NO2; SO2; acetic acid; and formic acid were assessed indoor and outdoor using passive diffusion tubes. BTEX were analyzed by GC-MS and other collected gasses by ion chromatography. Individual exposition of BTEX was assessed by personal passive diffusion tubes. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could affect the health of the scholars. In view of the chemical composition and size distribution of the aerosol particles, local deposition efficiencies in the children's respiratory systems were calculated, revealing the deposition of particles at extrathoracic

  6. Compliance with the annual NO 2 air quality standard in Athens. Required NO x levels and expected health implications

    Science.gov (United States)

    Chaloulakou, A.; Mavroidis, I.; Gavriil, I.

    Recent risk assessment studies have shown that high outdoor NO 2 levels observed in residential areas contribute to increased respiratory and cardiovascular diseases and mortality. Detailed information on present NO 2 levels as well as predictions of NO 2 concentrations corresponding to reduced NO x levels in urban areas are very useful to decision and policy makers in order to protect the public health. In the present paper, monitoring stations of the Athens network are initially classified into two main groups, traffic affected and urban background, using effectively a criterion based on the ratio of annual mean NO:NO 2 concentrations. Two empirical methodologies are then considered and compared for assessing the effect of different NO x levels on the attainment of the annual NO 2 air quality standard at urban-background locations in the Athens area. An interesting finding is that these two methodologies, one more general and one both year and site dependent, give similar results for the specific study area and can be applied alternatively based on the length of available concentration time series. The results show that in order to meet the EU annual mean NO 2 objective at all the urban-background locations of the Athens area, annual NO x concentrations should be reduced to approximately 60 μg m -3, requiring NO x emission reductions of up to 30%. An analysis of the health implications of the currently observed NO 2 levels is conducted, based on a dose-response relationship, and is coupled with available health-related data for the Athens area. This analysis suggests that if NO 2 concentrations were reduced to the levels of the annual EU air quality standard, then a decrease of hospital admissions of up to 2.6% would be observed, depending on the levels of NO 2 measured at different monitoring sites of the Athens conurbation.

  7. Comparative study on the health effects of smoking and indoor air pollution in summer and winter

    Energy Technology Data Exchange (ETDEWEB)

    Matsuki, H.; Kasuga, H.; Osaka, F.; Yanagisawa, Y.; Nishimura, H.

    1985-08-01

    This study compares summer and winter to demonstrate the health effects of indoor air pollution with special reference to NO/sub 2/ and smoking, on the subjects composed of 820 school children and their 546 mothers in the two areas with different ambient NO/sub 2/ concentrations. In either case, examination was carried out with standardized questionnaire test for respiratory symptoms, personal NO/sub 2/ exposure measurement using the filter badge by Yanagisawa, and analysis of urinary hydroxyproline and creatinine in two areas with different ambient NO/sub 2/ levels. Personal NO/sub 2/ exposure level in winter season was 2-3 times higher than that in summer, particularly NO/sub 2/ level among residents living in homes with non-vented stove for space heating was substantially higher from those of residents with vented stove. Wives with vented stove had a moderate exposure level in winter season by the contribution of NO/sub 2/ originated from the kitchen and poor ventilation rate. Since the hydroxyproline to creatinine ratio (HOP-ratio) of children increased more, their household location were nearer to any heavy traffic roads in summer, health effects from automobile exhaust were suggested only in summer season. In summer season, personal NO/sub 2/ exposure level were almost the same with the ambient NO/sub 2/ concentrations over both areas. These results suggest that indoor air pollution in winter season may be separated from outdoor air pollution. It was a matter of course that hydroxyproline to creatinine ratio in winter season was higher than that in summer, in any group and in any area, but the range of variation of hydroxyproline to creatinine ratio was smaller by far than that of personal NO/sub 2/ exposure level. Judging from urinary hydroxyproline to creatinine ratio, health effects of active smoking and passive smoking increased with increasing the number of smoked, dose-dependently in any season.

  8. Volatile organic compound conversion by ozone, hydroxyl radicals, and nitrate radicals in residential indoor air: Magnitudes and impacts of oxidant sources

    Science.gov (United States)

    Waring, Michael S.; Wells, J. Raymond

    2015-04-01

    Indoor chemistry may be initiated by reactions of ozone (O3), the hydroxyl radical (OH), or the nitrate radical (NO3) with volatile organic compounds (VOC). The principal indoor source of O3 is air exchange, while OH and NO3 formation are considered as primarily from O3 reactions with alkenes and nitrogen dioxide (NO2), respectively. Herein, we used time-averaged models for residences to predict O3, OH, and NO3 concentrations and their impacts on conversion of typical residential VOC profiles, within a Monte Carlo framework that varied inputs probabilistically. We accounted for established oxidant sources, as well as explored the importance of two newly realized indoor sources: (i) the photolysis of nitrous acid (HONO) indoors to generate OH and (ii) the reaction of stabilized Criegee intermediates (SCI) with NO2 to generate NO3. We found total VOC conversion to be dominated by reactions both with O3, which almost solely reacted with D-limonene, and also with OH, which reacted with D-limonene, other terpenes, alcohols, aldehydes, and aromatics. VOC oxidation rates increased with air exchange, outdoor O3, NO2 and D-limonene sources, and indoor photolysis rates; and they decreased with O3 deposition and nitric oxide (NO) sources. Photolysis was a strong OH formation mechanism for high NO, NO2, and HONO settings, but SCI/NO2 reactions weakly generated NO3 except for only a few cases.

  9. Environmental radon level and radiation dose to residents in Shanghai municipality

    International Nuclear Information System (INIS)

    Zhang Haoran; Chen Peihua; Wen Yin

    1992-01-01

    From 1987 to 1990 we observed the diurnal and seasonal changes of radon concentrations indoors and outdoors in Shanghai Municipality. The average equilibrium factors for radon decay products indoors and outdoors were 0.5 and 0.7, respectively. The indoor radon concentrations at city proper, town and rural area were 11.2, 10.5 and 13.6 Bq/m 3 , respectively. The outdoor radon concentration was 5.1 Bq/m 3 . The occupancy factors in the city proper were 0.82 and 0.18 in the adults, 0.87 and 0.13 in the children for indoor and outdoor exposures, respectively. In 1989 the population weighted means of the annual effective dose equivalent amounted to approximately 0.53 mSv. The collective dose equivalent was 6800 man. Sv

  10. Assement on level of indoor air quality at kindergartens in Ampang ...

    African Journals Online (AJOL)

    This study identify the air pollutant that occurs in the kindergartens, to measure the level of indoor air quality and also to analyze the association between indoor air quality patterns with respiratory health symptoms. Three kindergartens were selected based on types of building (single house, terraced 2 floors and refurbished ...

  11. Effect of efficient supply of pure O2 concentrated by PSA-type O2 separator on improvement of indoor air quality

    International Nuclear Information System (INIS)

    Han, Gi Bo; Jang, Jung Hee; Choi, Changsik; Lee, Tae Jin

    2016-01-01

    To minimize the cost and loss rate of energy artificial room ventilation system, the O 2 separator was suggested for the flow of the excessive ventilation amount between indoor and outdoor because the pure O 2 separated and concentrated by the O 2 separator can be supplied with the ventilation amount minimized. How the O 2 separator applies to ventilation and its operation characteristics were investigated by controlling under various conditions as well as the operation conditions optimized required for indoor air quality such as the concentration of CO 2 and O 2 . Consequently, it was known that the O 2 concentration was increased; however, the increase of the CO 2 concentration was suppressed by the sufficient supply of O 2 concentrated from the storage tank into the room despite the two persons’ breathing in the room having an inner volume of about 56m 3 . Consequently, it was concluded that the supply system of the concentrated O 2 which was stored into the tank after the production with the O 2 separator can be applied to the room ventilation system for the improvement of the indoor air quality.

  12. The measurement of the indoor absorbed dose rate in air in Beijing

    International Nuclear Information System (INIS)

    Guo Mingqiang; Pan Ziqiang; Yi Nanchang; Wei Zemin; Zhang Chao; Wang Huamin; Zhu Wencai

    1985-01-01

    This paper describes the indoor absorbed dose rate in air in Beijing. The average indoor absorbed dose rate in air is 8.29 μrad/h. The ratio of indoor to outdoor absorbed dose rate for 849 buildings is 1.51

  13. Sources and perceptions of indoor and ambient air pollution in rural Alaska.

    Science.gov (United States)

    Ware, Desirae; Lewis, Johnnye; Hopkins, Scarlett; Boyer, Bert; Noonan, Curtis; Ward, Tony

    2013-08-01

    Even though Alaska is the largest state in the United States, much of the population resides in rural and underserved areas with documented disparities in respiratory health. This is especially true in the Yukon-Kuskokwim (southwest) and Ahtna (southcentral) Regions of Alaska. In working with community members, the goal of this study was to identify the air pollution issues (both indoors and outdoors) of concern within these two regions. Over a two-year period, 328 air quality surveys were disseminated within seven communities in rural Alaska. The surveys focused on understanding the demographics, home heating practices, indoor activities, community/outdoor activities, and air quality perceptions within each community. Results from these surveys showed that there is elevated potential for PM10/PM2.5 exposures in rural Alaska communities. Top indoor air quality concerns included mold, lack of ventilation or fresh air, and dust. Top outdoor air pollution concerns identified were open burning/smoke, road dust, and vehicle exhaust (e.g., snow machines, ATVs, etc.). These data can now be used to seek additional funding for interventions, implementing long-term, sustainable solutions to the identified problems. Further research is needed to assess exposures to PM10/PM2.5 and the associated impacts on respiratory health, particularly among susceptible populations such as young children.

  14. Radon concentration in outdoor occupational environments in Aomori Prefecture, Japan

    International Nuclear Information System (INIS)

    Iyogi, T.; Ueda, S.; Hisamatsu, S.; Sakurai, N.; Inaba, J.

    2004-01-01

    The 222 Rn concentration in outdoor workplaces were measured in Aomori Prefecture, Japan as a part of a program on measurement of natural radiation background dose to people in the prefecture where Japan's first nuclear fuel cycling facilities are now under construction. 222 Rn concentrations were measured in 116 outdoor workplaces by passive Rn detectors for 10 months, which represented agricultural, forestry, fishery and construction/transportation workplaces. The 222 Rn concentrations in outdoor workplaces were generally lower than those in indoor environments. The dose to workers was estimated by using the results of the passive detectors as well as diurnal variation of 222 Rn and equilibrium factor measured with active-type detectors. The average dose from 222 Rn and its progenies to people in Aomori Prefecture was estimated as 0.39 mSv x y -1 based on the obtained results and results in indoor environments. The contribution of 222 Rn in outdoor workplaces to the total dose was 3.3% because of low occupancy ratio. (author)

  15. Roof radiation in indoor and covered outdoor skating rinks; Deckenstrahlung in Eishallen und ueberdeckten Ausseneisfeldern

    Energy Technology Data Exchange (ETDEWEB)

    Gachnang, F. [Eta Energietechnik GmbH, Winterthur (Switzerland); Mayer, H. [Gabathuler AG, Diessenhofen (Switzerland); Schweizer, A. [Baumgartner und Partner AG, Duebendorf (Switzerland); Krieg, J. [Zuercher Hochschule Winterthur, Winterthur (Switzerland)

    2005-07-01

    This report for the Swiss Federal Office of Energy (SFOE) presents the results of three measurement projects that examined the effect of low-emission materials mounted under the roofing in three different ice rinks on the energy consumption for the refrigeration and air-conditioning installations. In the first object, an indoor ice-hockey rink in Duebendorf, Switzerland, the effect of an aluminium cladding installed and the measurements made concerning the reduction of energy consumption are discussed. Their relevance to further covered ice rinks is examined. The second part takes a look at the effect of soiling and oxidation examined at a further skating rink in Kreuzlingen, Switzerland. The third part of the report examines three different roofing constructions newly installed over an outdoor rink. The findings of the three projects are discussed and recommendations are made.

  16. A new coating material for reducing indoor radon level

    International Nuclear Information System (INIS)

    Zhuo, W.; Tokonami, S.; Ichitsubo, H.; Yamada, Y.; Yamada, Y.

    2002-01-01

    In order to mitigate indoor radon level, a new fast-setting, solvent-free, polyurethane-based coating material was developed. The permeability of radon gas in the new material was estimated with a simple radon permeation test system set up in this study. It was found that the permeation velocity depended on the thickness of the coating material, and a thickness of 2.0 mm of the coating material seems sufficient for preventing radon permeation. The permeability of radon in the coating material was estimated to be (2.2± 0.8)x10 -10 m 2 ·s -1 for a thickness of about 1.0 mm. The value is much lower than those reported for membrane materials and caulking compounds. For its performance test, the coating material was used in an existing room with high radon level. By spraying a thickness of 1.5 mm of the material, the indoor radon level reduced by about 80%

  17. An indoor chemical cocktail

    Science.gov (United States)

    Gligorovski, Sasho; Abbatt, Jonathan P. D.

    2018-02-01

    In the past 50 years, many of the contaminants and chemical transformations that occur in outdoor waters, soils, and air have been elucidated. However, the chemistry of the indoor environment in which we live most of the time—up to 90% in some societies—is not nearly as well studied. Recent work has highlighted the wealth of chemical transformations that occur indoors. This chemistry is associated with 3 of the top 10 risk factors for negative health outcomes globally: household air pollution from solid fuels, tobacco smoking, and ambient particulate matter pollution (1). Assessments of human exposure to indoor pollutants must take these reactive processes into consideration.

  18. Growth and lipid accumulation characteristics of Scenedesmus obliquus in semi-continuous cultivation outdoors for biodiesel feedstock production.

    Science.gov (United States)

    Feng, Pingzhong; Yang, Kang; Xu, Zhongbin; Wang, Zhongming; Fan, Lu; Qin, Lei; Zhu, Shunni; Shang, Changhua; Chai, Peng; Yuan, Zhenhong; Hu, Lei

    2014-12-01

    In an effort to identify suitable microalgal species for biodiesel production, seven species were isolated from various habitats and their growth characteristics were compared. The results demonstrated that a green alga Scenedesmus obliquus could grow more rapidly and synthesize more lipids than other six microalgal strains. S. obliquus grew well both indoors and outdoors, and reached higher μmax indoors than that outdoors. However, the cells achieved higher dry weight (4.36 g L(-1)), lipid content (49.6%) and productivity (183 mg L(-1) day(-1)) outdoors than in indoor cultures. During the 61 days semi-continuous cultivation outdoors, high biomass productivities (450-550 mg L(-1) day(-1)) and μmax (1.05-1.44 day(-1)) were obtained. The cells could also achieve high lipid productivities (151-193 mg L(-1) day(-1)). These results indicated that S. obliquus was promising for lipids production in semi-continuous cultivation outdoors. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Pollution level, phase distribution and health risk of polycyclic aromatic hydrocarbons in indoor air at public places of Hangzhou, China

    International Nuclear Information System (INIS)

    Lu Hao; Zhu Lizhong; Chen Shuguang

    2008-01-01

    PAHs pollution survey in air of public places was conducted in Hangzhou, China. The most serious PAHs pollution was observed in indoor air of shopping centers and the slightest was in train stations. The molecular weight of chrysene (MW 228) appeared to be the dividing line for the PAHs with a larger or smaller distribution in the vapor or particulate phase. Concentrations of 15 PAHs on PM 2.5 accounted for 71.3% of total particulate PAHs, and followed by PM 2.5-10 fraction (17.6%) and >PM 10 fraction (11.1%). In shopping centers and supermarkets, emission of 2-4 rings PAHs occurred from indoor sources, whereas 5-6 rings PAHs predominantly originated from transport of outdoor air. In temples, PAHs in indoor air mainly originated from incense burning. Health risks associated with the inhalation of PAHs were assessed, and naphthalene made the greatest contribution (62.4%) to the total health risks. - Concentrations of PAHs in the air of selected public places in Hangzhou correspond to 10 -3 life-time lung cancer risk

  20. Leave no trace in the outdoors

    Science.gov (United States)

    Marion, Jeffrey L.

    2014-01-01

    The essential guide for enjoying the outdoors without harming the environment. - Details the seven core principles of Leave No Trace ethics and practices - Covers hiking, campfires, food storage, and personal hygiene - Endorsed by the USDI National Park Service, Bureau of Land Management, Fish & Wildlife Service, U.S. Geological Survey, and the USDA Forest Service

  1. Use of electronic cigarettes (e-cigarettes) impairs indoor air quality and increases FeNO levels of e-cigarette consumers.

    Science.gov (United States)

    Schober, Wolfgang; Szendrei, Katalin; Matzen, Wolfgang; Osiander-Fuchs, Helga; Heitmann, Dieter; Schettgen, Thomas; Jörres, Rudolf A; Fromme, Hermann

    2014-07-01

    Despite the recent popularity of e-cigarettes, to date only limited data is available on their safety for both users and secondhand smokers. The present study reports a comprehensive inner and outer exposure assessment of e-cigarette emissions in terms of particulate matter (PM), particle number concentrations (PNC), volatile organic compounds (VOC), polycyclic aromatic hydrocarbons (PAH), carbonyls, and metals. In six vaping sessions nine volunteers consumed e-cigarettes with and without nicotine in a thoroughly ventilated room for two hours. We analyzed the levels of e-cigarette pollutants in indoor air and monitored effects on FeNO release and urinary metabolite profile of the subjects. For comparison, the components of the e-cigarette solutions (liquids) were additionally analyzed. During the vaping sessions substantial amounts of 1,2-propanediol, glycerine and nicotine were found in the gas-phase, as well as high concentrations of PM2.5 (mean 197 μg/m(3)). The concentration of putative carcinogenic PAH in indoor air increased by 20% to 147 ng/m(3), and aluminum showed a 2.4-fold increase. PNC ranged from 48,620 to 88,386 particles/cm(3) (median), with peaks at diameters 24-36 nm. FeNO increased in 7 of 9 individuals. The nicotine content of the liquids varied and was 1.2-fold higher than claimed by the manufacturer. Our data confirm that e-cigarettes are not emission-free and their pollutants could be of health concern for users and secondhand smokers. In particular, ultrafine particles formed from supersaturated 1,2-propanediol vapor can be deposited in the lung, and aerosolized nicotine seems capable of increasing the release of the inflammatory signaling molecule NO upon inhalation. In view of consumer safety, e-cigarettes and nicotine liquids should be officially regulated and labeled with appropriate warnings of potential health effects, particularly of toxicity risk in children. Copyright © 2013 Elsevier GmbH. All rights reserved.

  2. Predicting residential indoor concentrations of nitrogen dioxide, fine particulate matter, and elemental carbon using questionnaire and geographic information system based data

    Science.gov (United States)

    Baxter, Lisa K.; Clougherty, Jane E.; Paciorek, Christopher J.; Wright, Rosalind J.; Levy, Jonathan I.

    Previous studies have identified associations between traffic-related air pollution and adverse health effects. Most have used measurements from a few central ambient monitors and/or some measure of traffic as indicators of exposure, disregarding spatial variability and factors influencing personal exposure-ambient concentration relationships. This study seeks to utilize publicly available data (i.e., central site monitors, geographic information system, and property assessment data) and questionnaire responses to predict residential indoor concentrations of traffic-related air pollutants for lower socioeconomic status (SES) urban households. As part of a prospective birth cohort study in urban Boston, we collected indoor and outdoor 3-4 day samples of nitrogen dioxide (NO 2) and fine particulate matter (PM 2.5) in 43 low SES residences across multiple seasons from 2003 to 2005. Elemental carbon (EC) concentrations were determined via reflectance analysis. Multiple traffic indicators were derived using Massachusetts Highway Department data and traffic counts collected outside sampling homes. Home characteristics and occupant behaviors were collected via a standardized questionnaire. Additional housing information was collected through property tax records, and ambient concentrations were collected from a centrally located ambient monitor. The contributions of ambient concentrations, local traffic and indoor sources to indoor concentrations were quantified with regression analyses. PM 2.5 was influenced less by local traffic but had significant indoor sources, while EC was associated with traffic and NO 2 with both traffic and indoor sources. Comparing models based on covariate selection using p-values or a Bayesian approach yielded similar results, with traffic density within a 50 m buffer of a home and distance from a truck route as important contributors to indoor levels of NO 2 and EC, respectively. The Bayesian approach also highlighted the uncertanity in the

  3. Can we establish relationship between outdoor air ventilation and health based on the published epidemiological data?

    DEFF Research Database (Denmark)

    Carrer, Paolo; Wargocki, Pawel; Fanetti, Annaclara

    2015-01-01

    Appropriate exposure control is prerogative for reducing the burden of disease (BOD) due to inadequate air quality indoors (IAQ). Ventilation with outdoor air is one of the available exposure control methods and is widespread. It is often assumed that this method will bring tangible effects...... exposures at various levels of ventilation were no characterized. It was observed that available data have many limitations, such as insufficient statistical power, incomplete data on the strength of pollution sources, diversity and variability of ventilation rates, at which effects have been seen...... exposures affecting health. It is concluded, that currently available epidemiological data do not provide sound basis for outdoor air ventilation requirements that can be universally applicable in different public and residential buildings to protect against health risks. They show minimum rates at which...

  4. Use of population exposure frequency distributions to simulate effects of policy interventions on NO2 exposure

    Science.gov (United States)

    Dimitroulopoulou, C.; Ashmore, M. R.; Terry, A. C.

    2017-02-01

    Health effects of air pollution on individuals depend on their personal exposure, but few modelling tools are available which can predict how the distribution of personal exposures within a city will change in response to policies to reduce emissions both indoors and outdoors. We describe a new probabilistic modelling framework (INDAIR-2/EXPAIR), which provides predictions of the personal exposure frequency distribution (PEFD) across a city to assess the effects of both reduced emissions from home sources and reduced roadside concentrations on population exposure. The model uses a national time activity database, which gives the percentage of each population group in different residential and non-residential micro-environments, and links this, for the home, to predictions of concentrations from a three-compartment model, and for non-residential microenvironments to empirical indoor/outdoor ratios. This paper presents modelled PEFDs for NO2 in the city of Leicester, for children, the elderly, and office workers, comparing results in different seasons and on different days of the week. While the mean NO2 population exposure was close to, or below the urban background concentration, the 95%ile of the PEFD was well above the urban background concentration. The relationship between both mean and 95%ile PEFD and urban background concentrations was strongly influenced by air exchange rate. The 24 h mean PEFD showed relative small differences between the population groups, with both removal of home sources and reductions of roadside concentrations on roads with a high traffic density having similar effects in reducing mean exposure. In contrast, the 1 h maximum of the PEFD was significantly higher for children and the elderly than for office workers, and showed a much greater response to reduced home emissions in these groups. The results demonstrate the importance of understanding the dynamics of NO2 exposure at a population level within different groups, if the benefits

  5. A MIMO-OFDM Testbed, Channel Measurements, and System Considerations for Outdoor-Indoor WiMAX

    Directory of Open Access Journals (Sweden)

    Torres

    2010-01-01

    Full Text Available The design, implementation, and test of a real-time flexible (Multiple Input Multiple Output-Orthogonal Frequency Division Multiplexing MIMO-OFDM IEEE 802.16 prototype are presented. For the design, a channel measurement campaign on the 3.5 GHz band has been carried out, focusing on outdoor-indoor scenarios. The analysis of measured channels showed that higher capacity can be achieved in case of obstructed scenarios and that (Channel Distribution Information at the Transmitter CDIT capacity is close to (Channel State Information at the Transmitter CSIT with much lower complexity and requirements in terms of channel estimation and feedback. The baseband prototype used an (Field Programmable Gate Array FPGA where enhanced signal processing algorithms are implemented in order to improve system performance. We have shown that for MIMO-OFDM systems, extra signal processing such as enhanced joint channel and frequency offset estimation is needed to obtain a good performance and approach in practice the theoretical capacity improvements.

  6. Radon survey in outdoor workplaces of the Nanbu area

    International Nuclear Information System (INIS)

    Iyogi, Takashi; Hisamatsu, Shunichi; Sakurai, Naoyuki; Koyama, Kenji

    1999-01-01

    We previously surveyed indoor Rn concentration in homes throughout Aomori Prefecture from 1991 to 1995, and found a mean Rn concentration of 9 Bq m -3 . For accurate evaluation of radiation dose from Rn, its concentration not only in the home but also in workplaces and schools is important, since workers and students spend approximately one-third of the day in these places. Then, we obtained indoor Rn concentrations in several workplaces and schools in Aomori Prefecture. Now, measurements of outdoor Rn in workplaces have been planned for the prefecture during a two year period. The results for half the prefecture, the Nanbu area are described here. Passive Rn detectors using polycarbonate film were employed for long-term monitoring. Diurnal variations of Rn and its daughter nuclides were measured by an active Rn detector with an ionization chamber and a working level meter, respectively. The geometric mean Rn concentration obtained with the passive detectors was approximately 3 Bq m -3 in the outdoor workplaces, and lower than that in the indoor workplaces and school (14 Bq m -3 ). The Rn concentrations in fishing boats and harbors were slightly lower than typical values and some data for forests were higher than other workplaces. The diurnal variations which were higher at night and lower during the day were observed by the active detectors. (author)

  7. Assessment of indoor air quality related to potential vapor intrusion: Issues for former manufactured gas plants

    International Nuclear Information System (INIS)

    Rames, Antoine; Guillossou, Gaelle; Ronga-Pezeret, Sylvaine; Hulot, Corinne

    2012-01-01

    The indoor air quality of buildings on sites with soil or groundwater contaminated with volatile or semi-volatile compounds can be degraded by potential vapor intrusion (VI) from these environmental media. For sites of former manufactured gas plants (MGP), the compounds that must be considered are BTEX (benzene, toluene, ethylbenzene, and xylenes), 8 of the 16 polycyclic aromatic hydrocarbons (PAHs) generally studied, and, to a lesser degree, phenol and hydrogen cyanide. Given the plausibility of VI and in accordance with current recommendations of the French Ministry of the Environment, measurements of indoor air quality (and outdoor air, for additional analyses) were conducted on two occasions during the winter and summer of 2010. These measurements simultaneously used multiple air sampling devices (Summa canisters, Gore modules, air pumps coupled to various matrices; such as XAD2, silica gel, etc.). Phenol and hydrogen cyanide have not previously been quantified (limit of quantification between 0.12 and 2.00 μg/m 3 ). BTEX and PAHs were found ubiquitously at concentrations on the order of 1 to 10 μg/m 3 for BTEX and naphthalene and one to ten ng/m 3 for PAHs other than naphthalene) at all 14 MGP and both control sites, regardless of where onsite the air was sampled (office, basement or crawl space, or outdoors). These levels (the maximum considered) do not allow us to conclude that the indoor air is degraded according to the official French guidelines for managing potentially contaminated sites and soils. Thus, no excess health risk is expected for residents of these sites because of exposure to possible VI, which cannot be ruled out in view of the ubiquity of some compounds. (authors)

  8. Leisure-time physical activity and circulating 25-hydroxyvitamin D levels in cancer survivors: a cross-sectional analysis using data from the US National Health and Nutrition Examination Survey.

    Science.gov (United States)

    Yang, Lin; Toriola, Adetunji T

    2017-07-10

    Circulating 25-hydroxyvitamin D (25-OHD) is associated with improved cancer prognosis in some studies, yet it may be a surrogate marker for physical activity. We investigated the associations of leisure-time physical activity (LTPA) with circulating 25-OHD levels in cancer survivors, and determined whether associations differ by indoor and outdoor activity. Cross-sectional study. The US National Health and Nutrition Examination Survey (NHANES). Cancer survivors with available data on demographic information, measures of adiposity, smoking history, self-reported LTPA and circulating 25-OHD levels in five waves of NHANES (2001-2010). Circulating 25-OHD levels. Multivariable linear regression and logistic regression models were used to evaluate the associations of self-reported LTPA with 25-OHD, adjusting for potential confounders. Due to the differences in LTPA measure, the analyses were conducted separately for 2001-2006 and 2007-2010 data. We further estimated associations by indoor and outdoor activity in the 2001-2006 data. There were 1530 cancer survivors (mean age=60.5 years, mean body mass index=28.6 kg/m 2 ). The prevalent cancer sites were breast (19.3%), prostate (18.8%), cervix (10.4%) and colon (8.6%). Compared with inactive cancer survivors, being physically active was associated with higher circulating 25-OHD levels (8.07 nmol/L, 95% CI 4.63 to 11.52) for 2001-2006 data. In the mutually adjusted model, higher outdoor activity (5.83 nmol/L, 95% CI 1.64 to 10.01), but not indoor activity (2.93 nmol/L, 95% CI -1.80 to 7.66), was associated with statistically significantly higher 25-OHD levels. The interaction between indoor and outdoor activities was, however, not significant (p=0.29). The only statistically significant association seen in the 2007-2010 data was among obese cancer survivors. Physical activity, particularly outdoor activity, is associated with higher 25-OHD levels in cancer survivors. In view of the possible beneficial effects

  9. Indoor air quality study of forty east Tennessee homes

    Energy Technology Data Exchange (ETDEWEB)

    Hawthorne, A.R.; Gammage, R.B.; Dudney, C.S.; Hingerty, B.E.; Schuresko, D.D.; Parzyck, D.C.; Womack, D.R.; Morris, S.A.; Westley, R.R.; White, D.A.

    1984-12-01

    Over a one-year period, measurements of indoor air pollutants (CO/sub x/, NO/sub x/, formaldehyde, volatile organics, particulates, and radon) were made in 40 homes in East Tennessee. The houses were of various ages with different types of insulation and heating. Over one-half of the houses exceeded the ASHRAE indoor ceiling guideline of 0.1 ppM for formaldehyde on at least one occasion. Over the duration of the study, older houses averaged 0.04 ppM of formaldehyde while houses less than 5 years old averaged 0.08 ppM (P < 0.01). The highest concentration of formaldehyde measured was 0.4 ppM in a new home. Diurnal and seasonal fluctuations in levels of formaldehyde in some homes were as much as twofold and tenfold, respectively. The highest levels of formaldehyde were usually recorded during summer months. The concentration in indoor air of various organics was at least tenfold higher than in outdoor air. Carbon monoxide and nitrgen oxides were usually <2 and <0.02 ppM, respectively, except when gas stoves or kerosene space heaters were operating, or when a car was running in the garage. In 30% of the houses, the annual indoor guideline for radon, 4 pCi/L, was exceeded. The mean radon level in houses built on the ridgelines was 4.4 pCi/L, while houses located in the valleys had a mean level of 1.7 pCi/L (P < 0.01). The factor having the most impact on infiltration was operation of the central duct fan of the heating, ventilation, and air conditioning system. The mean rate of air exchange increased from 0.39 to 0.74 h/sup -1/ when the duct fan was operated (measurements prior to December 1982). This report presents the study design and implementation, describes the monitoring protocols, and provides a complete set of the data collected during the project. 25 references, 29 figures, 42 tables.

  10. The lasting effect of limonene-induced particle formation on air quality in a genuine indoor environment.

    Science.gov (United States)

    Rösch, Carolin; Wissenbach, Dirk K; von Bergen, Martin; Franck, Ulrich; Wendisch, Manfred; Schlink, Uwe

    2015-09-01

    Atmospheric ozone-terpene reactions, which form secondary organic aerosol (SOA) particles, can affect indoor air quality when outdoor air mixes with indoor air during ventilation. This study, conducted in Leipzig, Germany, focused on limonene-induced particle formation in a genuine indoor environment (24 m(3)). Particle number, limonene and ozone concentrations were monitored during the whole experimental period. After manual ventilation for 30 min, during which indoor ozone levels reached up to 22.7 ppb, limonene was introduced into the room at concentrations of approximately 180 to 250 μg m(-3). We observed strong particle formation and growth within a diameter range of 9 to 50 nm under real-room conditions. Larger particles with diameters above 100 nm were less affected by limonene introduction. The total particle number concentrations (TPNCs) after limonene introduction clearly exceed outdoor values by a factor of 4.5 to 41 reaching maximum concentrations of up to 267,000 particles cm(-3). The formation strength was influenced by background particles, which attenuated the formation of new SOA with increasing concentration, and by ozone levels, an increase of which by 10 ppb will result in a six times higher TPNC. This study emphasizes indoor environments to be preferred locations for particle formation and growth after ventilation events. As a consequence, SOA formation can produce significantly higher amounts of particles than transported by ventilation into the indoor air.

  11. Healthy Zero Energy Buildings (HZEB) Program - Cross-Sectional Study of Contaminant Levels, Source, Strengths, and Ventilation Rates in Retail Stores

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu R.; Sidheswaran, Meera; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William

    2014-02-01

    This field study measured ventilation rates and indoor air quality parameters in 21 visits to retail stores in California. The data was collected to guide the development of new, science-based commercial building ventilation rate standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. Data collection occurred between September 2011 and March 2013. Three types of stores participated in this study: grocery stores, furniture/hardware stores, and apparel stores. Ventilation rates and indoor air contaminant concentrations were measured on a weekday, typically between 9 am and 6 pm. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California’s Title 24 Standard in all but one store. Even though there was adequate ventilation according to Title 24, concentrations of formaldehyde, acetaldehyde, and acrolein exceeded the most stringent chronic health guidelines. Other indoor air contaminants measured included carbon dioxide (CO{sub 2}), carbon monoxide (CO), ozone (O{sub 3}), and particulate matter (PM). Concentrations of CO{sub 2} were kept low by adequate ventilation, and were assumed low also because the sampling occurred on a weekday when retail stores were less busy. CO concentrations were also low. The indoor-outdoor ratios of O{sub 3} showed that the first-order loss rate may vary by store trade types and also by ventilation mode (mechanical versus natural). Analysis of fine and ultrafine PM measurements showed that a substantial portion of the particle mass in grocery stores with cooking-related emissions was in particles less than 0.3 μm. Stores without cooking as an indoor source had PM size distributions that were more similar indoors and outdoors. The whole-building emission rates of volatile organic compounds (VOCs) and PM were estimated from the measured ventilation rates and indoor and outdoor contaminant concentrations. Mass balance models were

  12. PM1 and PM2.5 ionic composition and VOCs measurements in two typical apartments in Athens, Greece: investigation of smoking contribution to indoor air concentrations.

    Science.gov (United States)

    Saraga, Dikaia E; Maggos, Thomas; Helmis, Constantinos G; Michopoulos, John; Bartzis, John G; Vasilakos, Christos

    2010-08-01

    During the last decades, the air quality of the city of Athens has been quite aggravated. Scientific interest has been focused on health effects caused by both outdoor and indoor air pollution. The purpose of this study was the presentation of results from air quality measurements in two similar typical Athenian apartments in the same suburban area. In addition, smoking contribution is investigated, as it is the main factor which differentiates the two apartments. The results showed that it is the outdoor environment that mainly contributes to the air quality of the non-smokers' house. In the second apartment, PM2.5, PM1, and benzene concentrations were found significantly higher due to smoking activity. In contrast, no clear difference in particulate matter ionic composition between the two areas was observed, although in the smoker's house, ion concentrations were found elevated. This observation amplifies the assumption that in the smoker's apartment, significant outdoor sources' contribution cannot be excluded.

  13. International standards for the indoor environment. Where are we and do they apply to Asian countries?

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2003-01-01

    On the international level, ISO (International Organization for Standardization), CEN (European Committee for Standardization) and ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers) are writing and reviewing standards relating to the indoor environment on a regular...... basis. This presentation will focus on the development of standards for the indoor thermal environment and indoor air quality (ventilation). In the future, recommendations for acceptable indoor environments will be specified as classes. This allows for national differences in the requirements as well...... as for designing buildings for different quality levels. Several of these standards have been developed mainly by experts from Europe, North America and Japan. Are there, however, special considerations relating to South-East Asia (lifestyle, outdoor climate, economy) that are not dealt with in these standards...

  14. Assessment of indoor air concentrations of VOCs and their associated health risks in the library of Jawaharlal Nehru University, New Delhi.

    Science.gov (United States)

    Kumar, Amit; Singh, Bhupendra Pratap; Punia, Monika; Singh, Deepak; Kumar, Krishan; Jain, V K

    2014-02-01

    The present work investigated the levels of total volatile organic compounds (TVOC) and benzene, toluene, ethylbenzene, m/p-xylene, and o-xylene (BTEX) in different microenvironments in the library of Jawaharlal Nehru University in summer and winter during 2011-2012. Carcinogenic and non-carcinogenic health risks due to organic compounds were also evaluated using US Environmental Protection Agency (USEPA) conventional approaches. Real-time monitoring was done for TVOC using a data-logging photo-ionization detector. For BTEX measurements, the National Institute for Occupational Safety and Health (NIOSH) standard method which consists of active sampling of air through activated charcoal, followed by analysis with gas chromatography, was performed. Simultaneously, outdoor measurements for TVOC and BTEX were carried out. Indoor concentrations of TVOC and BTEX (except benzene) were higher as compared to the outdoor for both seasons. Toluene and m/p-xylene were the most abundant organic contaminant observed in this study. Indoor to outdoor (I/O) ratios of BTEX compounds were generally greater than unity and ranged from 0.2 to 8.7 and 0.2 to 4.3 in winter and summer, respectively. Statistical analysis and I/O ratios showed that the dominant pollution sources mainly came from indoors. The observed mean concentrations of TVOC lie within the second group of the Molhave criteria of indoor air quality, indicating a multifactorial exposure range. The estimated lifetime cancer risk (LCR) due to benzene in this study exceeded the value of 1 × 10(-6) recommended by USEPA, and the hazard quotient (HQ) of non-cancer risk came under an acceptable range.

  15. Sensitization to Indigenous Pollen and Molds and Other Outdoor and Indoor Allergens in Allergic Patients From Saudi Arabia, United Arab Emirates, and Sudan

    Science.gov (United States)

    2012-01-01

    Background Airborne allergens vary from one climatic region to another. Therefore, it is important to analyze the environment of the region to select the most prevalent allergens for the diagnosis and treatment of allergic patients. Objective To evaluate the prevalence of positive skin tests to pollen and fungal allergens collected from local indigenous plants or isolated molds, as well as other outdoor and indoor allergens in allergic patients in 6 different geographical areas in the Kingdom of Saudi Arabia (KSA), the United Arab Emirates, and Sudan. Materials and methods Four hundred ninety-two consecutive patients evaluated at different Allergy Clinics (276 women and 256 men; mean age, 30 years) participated in this study. The selection of indigenous allergens was based on research findings in different areas from Riyadh and adjoining areas. Indigenous raw material for pollen grains was collected from the desert near the capital city of Riyadh, KSA. The following plants were included: Chenopodium murale, Salsola imbricata, Rumex vesicarius, Ricinus communis, Artiplex nummularia, Amaranthus viridis, Artemisia monosperma, Plantago boissieri, and Prosopis juliflora. Indigenous molds were isolated from air sampling in Riyadh and grown to obtain the raw material. These included the following: Ulocladium spp., Penicillium spp., Aspergillus fumigatus, Cladosporium spp., and Alternaria spp. The raw material was processed under Good Manufacturing Practices for skin testing. Other commercially available outdoor (grass and tree pollens) and indoor (mites, cockroach, and cat dander) allergens were also tested. Results The highest sensitization to indigenous pollens was detected to C. murale (32%) in Khartoum (Sudan) and S. imbricata (30%) and P. juliflora (24%) in the Riyadh region. The highest sensitization to molds was detected in Khartoum, especially to Cladosporium spp. (42%), Aspergillus (40%), and Alternaria spp. (38%). Sensitization to mites was also very prevalent

  16. Indoor navigation by image recognition

    Science.gov (United States)

    Choi, Io Teng; Leong, Chi Chong; Hong, Ka Wo; Pun, Chi-Man

    2017-07-01

    With the progress of smartphones hardware, it is simple on smartphone using image recognition technique such as face detection. In addition, indoor navigation system development is much slower than outdoor navigation system. Hence, this research proves a usage of image recognition technique for navigation in indoor environment. In this paper, we introduced an indoor navigation application that uses the indoor environment features to locate user's location and a route calculating algorithm to generate an appropriate path for user. The application is implemented on Android smartphone rather than iPhone. Yet, the application design can also be applied on iOS because the design is implemented without using special features only for Android. We found that digital navigation system provides better and clearer location information than paper map. Also, the indoor environment is ideal for Image recognition processing. Hence, the results motivate us to design an indoor navigation system using image recognition.

  17. Indoor inhalation intake fractions of fine particulate matter: Review of influencing factors

    DEFF Research Database (Denmark)

    Hodas, Natasha; Loh, Miranda; Shin, Hyeong-Moo

    2016-01-01

    Exposure to fine particulate matter (PM2.5) is a major contributor to the global human disease burden. The indoor environment is of particular importance when considering the health effects associated with PM2.5 exposures because people spend the majority of their time indoors and PM2.5 exposures...... per unit mass emitted indoors are two to three orders of magnitude larger than exposures to outdoor emissions. Variability in indoor PM2.5 intake fraction (iFin,total), which is defined as the integrated cumulative intake of PM2.5 per unit of emission, is driven by a combination of building......-specific, human-specific, and pollutant-specific factors. Due to a limited availability of data characterizing these factors, however, indoor emissions and intake of PM2.5 are not commonly considered when evaluating the environmental performance of product life cycles. With the aim of addressing this barrier...

  18. Indoor air quality and infiltration in multifamily naval housing

    International Nuclear Information System (INIS)

    Parker, G.B.; Wilfert, G.L.; Dennis, G.W.

    1984-11-01

    Measurements of indoor air quality and air infiltration were taken in three units of a multifamily housing complex at the Naval Submarine base in Bangor, Washington, over 5 consecutive days during the heating season of 1983. Three dwelling units of identical size constructed in 1978 were monitored, each in a separate two-story four-unit complex. One unit was a downstairs unit and the other two units were upstairs units. Two of the units were occupied by smokers (one downstairs and one upstairs). None of the units had combustion appliances. Pollutants monitored indoors included radon, formaldehyde, carbon monoxide, particulate matter, and nitrogen dioxide. Indoor and outdoor temperature and windspeed were also recorded. Outdoor formaldehyde and nitrogen dioxide were also measured. Air exchange was measured about three times during each 24-h period, using a perfluorocarbon tracer with automatic tracer sampling. The daily average air exchange rate ranged from 0.22 to 0.91 air changes per hour (ACH). Pollutant concentrations were generally low except for particulate matter in the units with smokers, which were two to four times higher than in the unit with nonsmokers. Levels of carbon monoxide were also slightly elevated in one of the units with a smoker compared to the unit with nonsmokers. 5 references, 4 figures, 4 tables

  19. The Processing Speed of Scene Categorization at Multiple Levels of Description: The Superordinate Advantage Revisited.

    Science.gov (United States)

    Banno, Hayaki; Saiki, Jun

    2015-03-01

    Recent studies have sought to determine which levels of categories are processed first in visual scene categorization and have shown that the natural and man-made superordinate-level categories are understood faster than are basic-level categories. The current study examined the robustness of the superordinate-level advantage in a visual scene categorization task. A go/no-go categorization task was evaluated with response time distribution analysis using an ex-Gaussian template. A visual scene was categorized as either superordinate or basic level, and two basic-level categories forming a superordinate category were judged as either similar or dissimilar to each other. First, outdoor/ indoor groups and natural/man-made were used as superordinate categories to investigate whether the advantage could be generalized beyond the natural/man-made boundary. Second, a set of images forming a superordinate category was manipulated. We predicted that decreasing image set similarity within the superordinate-level category would work against the speed advantage. We found that basic-level categorization was faster than outdoor/indoor categorization when the outdoor category comprised dissimilar basic-level categories. Our results indicate that the superordinate-level advantage in visual scene categorization is labile across different categories and category structures. © 2015 SAGE Publications.

  20. Composition of PM2.5 and PM1 on high and low pollution event days and its relation to indoor air quality in a home for the elderly.

    Science.gov (United States)

    Buczyńska, Anna J; Krata, Agnieszka; Van Grieken, Rene; Brown, Andrew; Polezer, Gabriela; De Wael, Karolien; Potgieter-Vermaak, Sanja

    2014-08-15

    Many studies probing the link between air quality and health have pointed towards associations between particulate matter (PM) exposure and decreased lung function, aggravation of respiratory diseases like asthma, premature death and increased hospitalisation admissions for the elderly and individuals with cardiopulmonary diseases. Of recent, it is believed that the chemical composition and physical properties of PM may contribute significantly to these adverse health effects. As part of a Belgian Science Policy project ("Health effects of particulate matter in relation to physical-chemical characteristics and meteorology"), the chemical composition (elemental and ionic compositions) and physical properties (PM mass concentrations) of PM were investigated, indoors and outdoors of old age homes in Antwerp. The case reported here specifically relates to high versus normal/low pollution event periods. PM mass concentrations for PM1 and PM2.5 fractions were determined gravimetrically after collection via impaction. These same samples were hence analysed by EDXRF spectrometry and IC for their elemental and ionic compositions, respectively. During high pollution event days, PM mass concentrations inside the old age home reached 53 μg m(-3) and 32 μg m(-3) whilst outside concentrations were 101 μg m(-3) and 46 μg m(-3) for PM2.5 and PM1, respectively. The sum of nss-sulphate, nitrate and ammonium, dominate the composition of PM, and contribute the most towards an increase in the PM during the episode days constituting 64% of ambient PM2.5 (52 μg m(-3)) compared to 39% on non-episode days (10 μg m(-3)). Other PM components, such as mineral dust, sea salt or heavy metals were found to be considerably higher during PM episodes but relatively less important. Amongst heavy metals Zn and Pb were found at the highest concentrations in both PM2.5 and PM1. Acid-base ionic balance equations were calculated and point to acidic aerosols during event days and acidic to alkaline

  1. Indoor radon concentration levels, gamma dose rates and impact of geology - A case study in Kotli, State of Azad Jammu and Kashmir, sub-Himalayas, in Pakistan

    International Nuclear Information System (INIS)

    Iqbal, A.; Shahid Baig, M.; Akram, M.; Qureshi, A.A.

    2012-01-01

    Inhalation of indoor radon has been recognized as the largest contributor to the total effective dose received by human beings. Indoor radon data were collected from the dwellings lying on the sedimentary rocks (sandstones, siltstones and clays) of the Murree Formation, Nagri Formation, Dhok Pathan Formation, Mirpur conglomerate and surficial deposits of the Kotli area in Azad Jammu and Kashmir, Pakistan. Radon measurements were made using the passive time-integrated method using Kodak CN-85 Solid-State Nuclear Track Detectors. The radon concentration in dwellings varied from 13 ± 6 Bq.m -3 to 185 ± 23 Bq.m -3 , with an average of 73 ± 15 Bq.m -3 .The radon concentration in the Murree Formation, Nagri Formation, river terrace and Dhok Pathan Formation were 89.7 ± 16.5, 72 ± 15, 68.5 and 69 Bq.m -3 , respectively. The average value of all the measured concentrations (73 ± 15 Bq.m -3 ) within the framework of this study is more than the world average value of 40 Bq.m -3 given by UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation, report to the General Assembly, United Nations, New York, 2000) and is within the action level of 200-600 Bq.m -3 fixed by the ICRP (International Commission on Radiological Protection, ICRP publication 65, Protection against radon at home and at work, 1993). The ambient gamma dose rates both indoors and outdoors in different parts of Kotli were also measured. The average value of gamma absorbed dose rates prevailing in the indoor environment was 131.2 ± 16.6 nGy/h. The gamma exposure rates recorded outdoors were 35% lower than in the indoor environment. The measured gamma dose rates have a weak positive correlation with indoor radon concentration. The annual effective dose for inhabitants in Kotli due to radon ranged from 0.32 to 4.7 mSv.y -1 , with an average value of 1.8 mSv.y -1 . This dose is relatively higher than the world mean dose of 1.15 mSv/y. That is explained by the particular geology of the

  2. Dairy cow preference for different types of outdoor access.

    Science.gov (United States)

    Smid, Anne-Marieke C; Weary, Daniel M; Costa, Joao H C; von Keyserlingk, Marina A G

    2018-02-01

    Dairy cows display a partial preference for being outside, but little is known about what aspects of the outdoor environment are important to cows. The primary aim of this study was to test the preference of lactating dairy cattle for pasture versus an outdoor sand pack during the night. A secondary aim was to determine whether feeding and perching behavior changed when cows were provided outdoor access. A third objective was to investigate how the lying behavior of cows changed when given access to different outdoor areas. Ninety-six lactating pregnant cows were assigned to 8 groups of 12 animals each. After a baseline phase of 2 d in which cows were kept inside the freestall barn, cows were habituated to the outdoor areas by providing them access to each of the 2 options for 24 h. Cows were then given access, in random order by group, to either the pasture (pasture phase) or the sand pack (sand phase). As we tested the 2 outdoor options using space allowances consistent with what would be practical on commercial dairy farms, the space provided on pasture was larger (21,000 m 2 ) than that provided on the sand pack (144 m 2 ). Cows were tested at night (for 2 nights in each condition), from 2000 h until morning milking at approximately 0800 h, as preference to be outdoors is strongest at this time. During the next 3 nights cows were given access to both outside options simultaneously (choice phase). Feeding and perching behaviors were recorded when cows were indoors during the day and night periods. Lying behavior was automatically recorded by HOBO data loggers (Onset, Bourne, MA). Cows spent more time outside in the pasture phase (90.0 ± 5.9%) compared with the sand phase (44.4 ± 6.3%). When provided simultaneous access to both options, cows spent more time on pasture than on the sand pack (90.5 ± 2.6% vs. 0.8 ± 0.5%, respectively). Time spent feeding indoors during the day did not change regardless of what type of outdoor access was provided, but there was a

  3. D Reconstruction of Cultural Tourism Attractions from Indoor to Outdoor Based on Portable Four-Camera Stereo Vision System

    Science.gov (United States)

    Shao, Z.; Li, C.; Zhong, S.; Liu, B.; Jiang, H.; Wen, X.

    2015-05-01

    Building the fine 3D model from outdoor to indoor is becoming a necessity for protecting the cultural tourism resources. However, the existing 3D modelling technologies mainly focus on outdoor areas. Actually, a 3D model should contain detailed descriptions of both its appearance and its internal structure, including architectural components. In this paper, a portable four-camera stereo photographic measurement system is developed, which can provide a professional solution for fast 3D data acquisition, processing, integration, reconstruction and visualization. Given a specific scene or object, it can directly collect physical geometric information such as positions, sizes and shapes of an object or a scene, as well as physical property information such as the materials and textures. On the basis of the information, 3D model can be automatically constructed. The system has been applied to the indooroutdoor seamless modelling of distinctive architecture existing in two typical cultural tourism zones, that is, Tibetan and Qiang ethnic minority villages in Sichuan Jiuzhaigou Scenic Area and Tujia ethnic minority villages in Hubei Shennongjia Nature Reserve, providing a new method and platform for protection of minority cultural characteristics, 3D reconstruction and cultural tourism.

  4. Individual Differences and Possible Effects from Outdoor Education: Long Time and Short Time Benefits

    Science.gov (United States)

    Fiskum, Tove Anita; Jacobsen, Karl

    2012-01-01

    This study explores differences in the children's outcomes from outdoor education. The results revealed different outcomes within different subgroups: The children with an easy or a withdrawal temperament are good functioning both indoor and outdoor. Their outcomes from outdoor education are an increased vitality, which might be seen as a short…

  5. Healthy environment — indoor air quality of Brazilian elementary schools nearby petrochemical industry

    International Nuclear Information System (INIS)

    Godoi, Ricardo H.M.; Godoi, Ana F.L.; Gonçalves Junior, Sérgio J.; Paralovo, Sarah L.; Borillo, Guilherme C.; Gonçalves Gregório Barbosa, Cybelli; Arantes, Manoela G.; Charello, Renata C.; Rosário Filho, Nelson A.; Grassi, Marco T.; Yamamoto, Carlos I.; Potgieter-Vermaak, Sanja; Rotondo, Giuliana G.; De Wael, Karolien; Grieken, Rene van

    2013-01-01

    The mitigation of pollution released to the environment originating from the industrial sector has been the aim of all policy-makers and its importance is evident if the adverse health effects on the world population are considered. Although this concern is controversial, petroleum refinery has been linked to some adverse health effects for people living nearby. Apart from home, school is the most important indoor environment for children and there is increasing concern about the school environment and its impact on health, also in developing countries where the prevalence of pollution is higher. As most of the children spend more than 40% of their time in schools, it is critical to evaluate the pollution level in such environment. In the metropolitan region of Curitiba, South Brazil, five schools nearby industries and highways with high density traffic, were selected to characterize the aerosol and gaseous compounds indoor and outdoor of the classrooms, during 2009–2011. Size segregated aerosol samples were collected for analyses of bulk and single particle elemental profiles. They were analyzed by electron probe X-ray micro-analysis (EPXMA), and by energy-dispersive X-ray fluorescence (EDXRF), to investigate the elemental composition of individual particles and bulk samples. The concentrations of benzene, toluene, ethylbenzene, and xylene (BTEX); NO 2 ; SO 2 ; acetic acid; and formic acid were assessed indoor and outdoor using passive diffusion tubes. BTEX were analyzed by GC–MS and other collected gasses by ion chromatography. Individual exposition of BTEX was assessed by personal passive diffusion tubes. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could affect the health of the scholars. In view of the chemical composition and size distribution of the aerosol particles, local deposition efficiencies in the children's respiratory systems were calculated, revealing the deposition of particles at

  6. Healthy environment — indoor air quality of Brazilian elementary schools nearby petrochemical industry

    Energy Technology Data Exchange (ETDEWEB)

    Godoi, Ricardo H.M., E-mail: rhmgodoi@ufpr.br [Department of Environmental Engineering, Federal University of Paran UFPR, Curitiba, PR (Brazil); Godoi, Ana F.L.; Gonçalves Junior, Sérgio J.; Paralovo, Sarah L.; Borillo, Guilherme C.; Gonçalves Gregório Barbosa, Cybelli; Arantes, Manoela G.; Charello, Renata C. [Department of Environmental Engineering, Federal University of Paran UFPR, Curitiba, PR (Brazil); Rosário Filho, Nelson A. [Department of Pediatric, Div. of Allergy and Pneumol, Federal University of Paran Curitiba, PR (Brazil); Grassi, Marco T. [Department of Chemistry, Federal University of Paraná, Curitiba, PR (Brazil); Yamamoto, Carlos I. [Department of Chemistry Engineering, Federal University of Paraná, Curitiba, PR (Brazil); Potgieter-Vermaak, Sanja [Division of Chemistry and Environmental Science, School of Science and the Environment, Manchester Metropolitan University, Manchester (United Kingdom); Rotondo, Giuliana G.; De Wael, Karolien; Grieken, Rene van [Department of Chemistry, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp (Belgium)

    2013-10-01

    The mitigation of pollution released to the environment originating from the industrial sector has been the aim of all policy-makers and its importance is evident if the adverse health effects on the world population are considered. Although this concern is controversial, petroleum refinery has been linked to some adverse health effects for people living nearby. Apart from home, school is the most important indoor environment for children and there is increasing concern about the school environment and its impact on health, also in developing countries where the prevalence of pollution is higher. As most of the children spend more than 40% of their time in schools, it is critical to evaluate the pollution level in such environment. In the metropolitan region of Curitiba, South Brazil, five schools nearby industries and highways with high density traffic, were selected to characterize the aerosol and gaseous compounds indoor and outdoor of the classrooms, during 2009–2011. Size segregated aerosol samples were collected for analyses of bulk and single particle elemental profiles. They were analyzed by electron probe X-ray micro-analysis (EPXMA), and by energy-dispersive X-ray fluorescence (EDXRF), to investigate the elemental composition of individual particles and bulk samples. The concentrations of benzene, toluene, ethylbenzene, and xylene (BTEX); NO{sub 2}; SO{sub 2}; acetic acid; and formic acid were assessed indoor and outdoor using passive diffusion tubes. BTEX were analyzed by GC–MS and other collected gasses by ion chromatography. Individual exposition of BTEX was assessed by personal passive diffusion tubes. Results are interpreted separately and as a whole with the specific aim of identifying compounds that could affect the health of the scholars. In view of the chemical composition and size distribution of the aerosol particles, local deposition efficiencies in the children's respiratory systems were calculated, revealing the deposition of

  7. Indoor particulate matter in developing countries: a case study in Pakistan and potential intervention strategies

    Science.gov (United States)

    Nasir, Zaheer Ahmad; Colbeck, Ian; Ali, Zulfiqar; Ahmad, Shakil

    2013-06-01

    Around three billion people, largely in low and middle income countries, rely on biomass fuels for their household energy needs. The combustion of these fuels generates a range of hazardous indoor air pollutants and is an important cause of morbidity and mortality in developing countries. Worldwide, it is responsible for four million deaths. A reduction in indoor smoke can have a significant impact on lives and can help achieve many of the Millennium Developments Goals. This letter presents details of a seasonal variation in particulate matter (PM) concentrations in kitchens using biomass fuels as a result of relocating the cooking space. During the summer, kitchens were moved outdoors and as a result the 24 h average PM10, PM2.5 and PM1 fell by 35%, 22% and 24% respectively. However, background concentrations of PM10 within the village increased by 62%. In locations where natural gas was the dominant fuel, the PM concentrations within the kitchen as well as outdoors were considerably lower than those in locations using biomass. These results highlights the importance of ventilation and fuel type for PM levels and suggest that an improved design of cooking spaces would result in enhanced indoor air quality.

  8. Indoor particulate matter in developing countries: a case study in Pakistan and potential intervention strategies

    International Nuclear Information System (INIS)

    Nasir, Zaheer Ahmad; Colbeck, Ian; Ali, Zulfiqar; Ahmad, Shakil

    2013-01-01

    Around three billion people, largely in low and middle income countries, rely on biomass fuels for their household energy needs. The combustion of these fuels generates a range of hazardous indoor air pollutants and is an important cause of morbidity and mortality in developing countries. Worldwide, it is responsible for four million deaths. A reduction in indoor smoke can have a significant impact on lives and can help achieve many of the Millennium Developments Goals. This letter presents details of a seasonal variation in particulate matter (PM) concentrations in kitchens using biomass fuels as a result of relocating the cooking space. During the summer, kitchens were moved outdoors and as a result the 24 h average PM 10 , PM 2.5 and PM 1 fell by 35%, 22% and 24% respectively. However, background concentrations of PM 10 within the village increased by 62%. In locations where natural gas was the dominant fuel, the PM concentrations within the kitchen as well as outdoors were considerably lower than those in locations using biomass. These results highlights the importance of ventilation and fuel type for PM levels and suggest that an improved design of cooking spaces would result in enhanced indoor air quality. (letter)

  9. Indoor air pollution and cognitive function among older Mexican adults.

    Science.gov (United States)

    Saenz, Joseph L; Wong, Rebeca; Ailshire, Jennifer A

    2018-01-01

    A growing body of research suggests exposure to high levels of outdoor air pollution may negatively affect cognitive functioning in older adults, but less is known about the link between indoor sources of air pollution and cognitive functioning. We examine the association between exposure to indoor air pollution and cognitive function among older adults in Mexico, a developing country where combustion of biomass for domestic energy remains common. Data come from the 2012 Wave of the Mexican Health and Aging Study. The analytic sample consists of 13 023 Mexican adults over age 50. Indoor air pollution is assessed by the reported use of wood or coal as the household's primary cooking fuel. Cognitive function is measured with assessments of verbal learning, verbal recall, attention, orientation and verbal fluency. Ordinary least squares regression is used to examine cross-sectional differences in cognitive function according to indoor air pollution exposure while accounting for demographic, household, health and economic characteristics. Approximately 16% of the sample reported using wood or coal as their primary cooking fuel, but this was far more common among those residing in the most rural areas (53%). Exposure to indoor air pollution was associated with poorer cognitive performance across all assessments, with the exception of verbal recall, even in fully adjusted models. Indoor air pollution may be an important factor for the cognitive health of older Mexican adults. Public health efforts should continue to develop interventions to reduce exposure to indoor air pollution in rural Mexico. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  10. Environmental radiation levels around Nuclear Fuel Complex, Hyderabad during 1981-1988

    International Nuclear Information System (INIS)

    Mehta, Navnit; Lakshmanan, A.R.; Kathuria, S.P.; Nambi, K.S.V.

    1989-01-01

    This report presents environmental radiation monitoring results around Nuclear Ffuel Complex (NFC) at Hyderabad for the period, 1981-'88. During 1981-'83 only indoor radiations were monitored at 12 locations in the region of about 15 km. radius around NFC plant. However, during 1984-'88 both indoor and outdoor monitoring was done in a standardised manner at 8 locations. In this routine monitoring programme, environmental thermoluminescent dosimeters were used in quarterly integrating cycles. The average outdoor natural radiation level around NFC during 1984-'88 is found to be 227 ± 34 (σ) mR/y, which is the highest among the various sites in the country where DAE units are located. Such a high level of natural background radiation in and around Hyderabad is due to granitic terrains which normally have significant amounts of primordial radioactivity. The indoor to outdoor radiation ratio is found to be 1.35 ± 0.1 (σ). Application of this ratio on all the available indoor radiation monitoring results of 1981-'88 gives an estimate of 230 ± 26 mR/y as the average outdoor radiation level, and this is in very close agreement with the directly measured value mentioned earlier. The temporal variations seen in the quarterly results of each location have been tested for Normal and Log-Normal distributions and found to yield satisfactory correlations, although the plots reveal slight skewness; the latter however, could not be attributed to the NFC operations. (author). 7 refs., 4 tabs., 12 figs

  11. A study on seasonal variations of indoor gamma dose in Bangladesh

    International Nuclear Information System (INIS)

    Miah, M. Idrish

    2005-01-01

    Monthly variation of gamma dose rate measured in indoor air of buildings of Bangladesh was found to vary cosinusoidally through a period of 1 year. Significant seasonal variations were observed. Maximum dose rate, however, was observed in January and a minimum in July. Dose rate in January was 32% higher than the annual average, whereas dose rate in July was 50% lower. Seasonally varied ventilation and air exchange rates of the houses might play an important role in the observed variation. The average reduction with respect to winter dose was 59% in summer. Because of lower ventilation and air exchange rates between indoor and outdoor atmosphere, it is expected that the indoor dose rate would be higher in basements than that of upper floors. Monthly dose rate was also found to be influenced by the meteorological conditions. Correlations between dose rate and temperature (r 2 =0.85), rainfall (r=-0.83) and atmospheric pressure (r=0.92) were obtained, but no significant correlation (r=-0.45) was seen between dose rate and humidity. The results show that the seasonal variations of indoor dose rates should be taken into account to estimate annual effective dose equivalent. (author)

  12. A survey exploring self-reported indoor and outdoor footwear habits, foot problems and fall status in people with stroke and Parkinson's.

    Science.gov (United States)

    Bowen, Catherine; Ashburn, Ann; Cole, Mark; Donovan-Hall, Margaret; Burnett, Malcolm; Robison, Judy; Mamode, Louis; Pickering, Ruth; Bader, Dan; Kunkel, Dorit

    Ill-fitting shoes have been implicated as a risk factor for falls but research to date has focused on people with arthritis, diabetes and the general older population; little is known about people with neurological conditions. This survey for people with stroke and Parkinson's explored people's choice of indoor and outdoor footwear, foot problems and fall history. Following ethical approval, 1000 anonymous postal questionnaires were distributed to health professionals, leads of Parkinson's UK groups and stroke clubs in the wider Southampton area, UK. These collaborators handed out survey packs to people with a confirmed diagnosis of stroke or Parkinson's. Three hundred and sixty three completed surveys were returned (218 from people with Parkinson's and 145 from people with stroke). Most respondents wore slippers indoors and walking shoes outdoors and considered comfort and fit the most important factors when buying footwear. Foot problems were reported by 43 % (95 % confidence intervals 36 to 52 %; stroke) and 53 % (95 % confidence interval 46 to 59 %; Parkinson's) of respondents; over 50 % had never accessed foot care support. Fifty percent of all respondents reported falls. In comparison to non-fallers, a greater proportion of fallers reported foot problems (57 %), with greater proportions reporting problems impacting on balance and influencing choice of footwear ( p  footwear habits and choice of footwear; however many did not receive foot care support. These findings highlight that further exploration of footwear and foot problems in these populations is warranted to provide evidence based advice on safe and appropriate footwear to support rehabilitation and fall prevention.

  13. Secondhand smoke exposure levels in outdoor hospitality venues: a qualitative and quantitative review of the research literature.

    Science.gov (United States)

    Licht, Andrea S; Hyland, Andrew; Travers, Mark J; Chapman, Simon

    2013-05-01

    This paper considers the evidence on whether outdoor secondhand smoke (SHS) is present in hospitality venues at high levels enough to potentially pose health risks, particularly among employees. Searches in PubMed and Web of Science included combinations of environmental tobacco smoke, secondhand smoke, or passive smoke AND outdoor, yielding 217 and 5,199 results, respectively through June, 2012. Sixteen studies were selected that reported measuring any outdoor SHS exposures (particulate matter (PM) or other SHS indicators). The SHS measurement methods were assessed for inclusion of extraneous variables that may affect levels or the corroboration of measurements with known standards. The magnitude of SHS exposure (PM2.5) depends on the number of smokers present, measurement proximity, outdoor enclosures, and wind. Annual excess PM2.5 exposure of full-time waitstaff at outdoor smoking environments could average 4.0 to 12.2 μg/m3 under variable smoking conditions. Although highly transitory, outdoor SHS exposures could occasionally exceed annual ambient air quality exposure guidelines. Personal monitoring studies of waitstaff are warranted to corroborate these modeled estimates.

  14. Determining the ventilation and aerosol deposition rates from routine indoor-air measurements.

    Science.gov (United States)

    Halios, Christos H; Helmis, Costas G; Deligianni, Katerina; Vratolis, Sterios; Eleftheriadis, Konstantinos

    2014-01-01

    Measurement of air exchange rate provides critical information in energy and indoor-air quality studies. Continuous measurement of ventilation rates is a rather costly exercise and requires specific instrumentation. In this work, an alternative methodology is proposed and tested, where the air exchange rate is calculated by utilizing indoor and outdoor routine measurements of a common pollutant such as SO2, whereas the uncertainties induced in the calculations are analytically determined. The application of this methodology is demonstrated, for three residential microenvironments in Athens, Greece, and the results are also compared against ventilation rates calculated from differential pressure measurements. The calculated time resolved ventilation rates were applied to the mass balance equation to estimate the particle loss rate which was found to agree with literature values at an average of 0.50 h(-1). The proposed method was further evaluated by applying a mass balance numerical model for the calculation of the indoor aerosol number concentrations, using the previously calculated ventilation rate, the outdoor measured number concentrations and the particle loss rates as input values. The model results for the indoors' concentrations were found to be compared well with the experimentally measured values.

  15. Level of terrestrial gamma radiation and doses to population in Jiangsu province

    International Nuclear Information System (INIS)

    1985-01-01

    In this paper the results of investigation of terrestrial gamma radiation level in Jiangsu Province are reported and the population doses due to this radiation are estimated. The sketch map of the geographical distribution of the terrestrial gamma radiation level is given. In this investigation FD-71 portable scintillation counters and RSS-111 high pressure ionization chambers were used. The results showed that the terrestrial gamma absorbed dose rates in air for indoors and outdoors were 10.7 x 10 -8 Gy/h and 6.5 x 10 -8 Gy/h (weighted values) respectively. The indoors-to-outdoors ratio was 1.65. The total (indoor plus outdoor) annual effective dose equivalent from terrestrial gamma radiation, averaged over the population in this province, was 6.0 x 10 -4 Sv. The collective annual effective dose equivalent was 3.6 x 10 4 man.Sv. Therefore, the absorbed dose to population in Jiangsu Province is in the range of the normal background

  16. Rethinking Indoor Localization Solutions Towards the Future of Mobile Location-Based Services

    Science.gov (United States)

    Guney, C.

    2017-11-01

    Satellite navigation systems with GNSS-enabled devices, such as smartphones, car navigation systems, have changed the way users travel in outdoor environment. GNSS is generally not well suited for indoor location and navigation because of two reasons: First, GNSS does not provide a high level of accuracy although indoor applications need higher accuracies. Secondly, poor coverage of satellite signals for indoor environments decreases its accuracy. So rather than using GNSS satellites within closed environments, existing indoor navigation solutions rely heavily on installed sensor networks. There is a high demand for accurate positioning in wireless networks in GNSS-denied environments. However, current wireless indoor positioning systems cannot satisfy the challenging needs of indoor location-aware applications. Nevertheless, access to a user's location indoors is increasingly important in the development of context-aware applications that increases business efficiency. In this study, how can the current wireless location sensing systems be tailored and integrated for specific applications, like smart cities/grids/buildings/cars and IoT applications, in GNSS-deprived areas.

  17. RETHINKING INDOOR LOCALIZATION SOLUTIONS TOWARDS THE FUTURE OF MOBILE LOCATION-BASED SERVICES

    Directory of Open Access Journals (Sweden)

    C. Guney

    2017-11-01

    Full Text Available Satellite navigation systems with GNSS-enabled devices, such as smartphones, car navigation systems, have changed the way users travel in outdoor environment. GNSS is generally not well suited for indoor location and navigation because of two reasons: First, GNSS does not provide a high level of accuracy although indoor applications need higher accuracies. Secondly, poor coverage of satellite signals for indoor environments decreases its accuracy. So rather than using GNSS satellites within closed environments, existing indoor navigation solutions rely heavily on installed sensor networks. There is a high demand for accurate positioning in wireless networks in GNSS-denied environments. However, current wireless indoor positioning systems cannot satisfy the challenging needs of indoor location-aware applications. Nevertheless, access to a user’s location indoors is increasingly important in the development of context-aware applications that increases business efficiency. In this study, how can the current wireless location sensing systems be tailored and integrated for specific applications, like smart cities/grids/buildings/cars and IoT applications, in GNSS-deprived areas.

  18. Indoor Thermal Environment in Tropical Climate Residential Building

    Directory of Open Access Journals (Sweden)

    Jamaludin Nazhatulzalkis

    2014-01-01

    Full Text Available Indoor thermal environment is one of the criteria in sustainable building. This criterion is important in ensuring a healthy indoor environment for the occupants. The consideration of environmental concerns at the early design stage would effectively integrate the sustainability of the building environment. Global climate changes such as global warming do affect human comfort since people spend most of their time and activities in the building. The increasing of urban population required additional housing for households, as well as places to shop, office and other facilities. Occupants are now more conscious the importance of sustainability for a better quality of life. Good thermal environment is essential for human wellness and comfort. A residential environment will influence residents’ health and safety. The global warming increase the earth’s temperature and greenhouse emission to the atmosphere cause adverse effects to the outdoor environment. Residential developments modify the materials, structure and energy balance in urban climate effects of human economic activities. As an indoor environment is influenced by the outdoor condition, the factors affecting indoor thermal environment are crucial in improving a comfortable and healthy environment in residential building. The microclimatic of a site such as temperature and relative humidity, and wind movement led to the variation of indoor thermal environment in the building.

  19. A Movement-Assisted Deployment of Collaborating Autonomous Sensors for Indoor and Outdoor Environment Monitoring.

    Science.gov (United States)

    Niewiadomska-Szynkiewicz, Ewa; Sikora, Andrzej; Marks, Michał

    2016-09-14

    Using mobile robots or unmanned vehicles to assist optimal wireless sensors deployment in a working space can significantly enhance the capability to investigate unknown environments. This paper addresses the issues of the application of numerical optimization and computer simulation techniques to on-line calculation of a wireless sensor network topology for monitoring and tracking purposes. We focus on the design of a self-organizing and collaborative mobile network that enables a continuous data transmission to the data sink (base station) and automatically adapts its behavior to changes in the environment to achieve a common goal. The pre-defined and self-configuring approaches to the mobile-based deployment of sensors are compared and discussed. A family of novel algorithms for the optimal placement of mobile wireless devices for permanent monitoring of indoor and outdoor dynamic environments is described. They employ a network connectivity-maintaining mobility model utilizing the concept of the virtual potential function for calculating the motion trajectories of platforms carrying sensors. Their quality and utility have been justified through simulation experiments and are discussed in the final part of the paper.

  20. Pilot study on indoor climate investigation and computer simulation in historical museum building: Amerongen Castle, the Netherlands

    Directory of Open Access Journals (Sweden)

    Raha Sulaiman

    2010-12-01

    Full Text Available The indoor climate is one of the most important factors contributing to climate-induced damage to the building materials and cultural collections of a monumental building. The Dutch monumental building - Amerongen Castle, and the collections housed in it show severe deterioration caused by inappropriate historical indoor environment. Assessments of the indoor climate, especially on the room temperature and relative humidity, are necessary to analyze the causes and impacts of climate change. As the building was flooded in year 1993 and 1996, extra attention is paid to investigate the effects of flooding to it. This pilot study was aimed to identify the buildup linkages between the known past, historical data on indoor environment and indoor climate performance in the building through simulation based-prediction. This paper focuses on the methodology of indoor climate investigation from the past to the current situation. A hypothesis was developed on backcasting-based prediction simulation which can be used to identify the accepted historical indoor climate where during those times there probably was no damage to the building and the collection. A simulation method based on heat, air and moisture transport is used with the HAMBase program. The computer model representing the Grand Salon of Amerongen Castle was calibrated by comparing real measurements to simulation results. It shows that the differences were only to the minimum of -1.8C and maximum of 3.2C. The data for the historical outdoor weather files was obtained by interpolating outdoor ancient climatology constructed by MATLAB. Based on archival research, indoor thermal history was gathered as input for the profiles used in simulation. Further, the calibrated computer model can be used to simulate past indoor climate and investigate the process of the deterioration of the room and the collections mainly due to the fluctuation of indoor temperature and relative humidity. At the end

  1. Statistical analysis of electromagnetic radiation measurements in the vicinity of indoor microcell GSM/UMTS base stations in Serbia.

    Science.gov (United States)

    Koprivica, Mladen; Petrić, Majda; Nešković, Nataša; Nešković, Aleksandar

    2016-01-01

    To determine the level of radiofrequency radiation generated by base stations of Global System for Mobile Communications and Universal Mobile Telecommunication System, extensive electromagnetic field strength measurements were carried out in the vicinity of 664 base station locations. These were classified into three categories: indoor, masts, and locations with installations on buildings. Although microcell base stations with antennas installed indoors typically emit less power than outdoor macrocell base stations, the fact that people can be found close to antennas requires exposure originating from these base stations to be carefully considered. Measurement results showed that maximum recorded value of electric field strength exceeded International Commission on Non-Ionizing Radiation Protection reference levels at 7% of indoor base station locations. At the same time, this percentage was much lower in the case of masts and installations on buildings (0% and 2.5%, respectively). © 2015 Wiley Periodicals, Inc.

  2. Natural external radiation level and population dose in Hunan province

    International Nuclear Information System (INIS)

    1985-01-01

    A survey of the natural external radiation level in Hunan Province is reported. The measurements were performed with FD-71 scintillation radiometers. On the basis of measurements at about 1,600 locations, the contribution from cosmic radiation is found to be 3.0 x 10 -8 Gy.h -1 , and the average absorbed dose rates in air from terrestrial γ-radiation for outdoors, indoors and roads are determined to be 9.2, 13.1 and 9.0 x 10 -8 Gy.h -1 , respectively. The γ-radiation indoors is markedly higher than that outdoors by a factor of 1.42. The lowest γ-radiation level is found in the sedimentary plain around Donting Lake, while the highest absorbed dose rates in air from terrestrial radiation are observed in some areas with exposed granites. The indoor γ-radiation in brick houses is markedly higher than that in wooden houses. Tarred roads have evidently lower radiation level than sand-gravel roads or concrete roads. The annual effective dose equivalents to the population from cosmic and terrestrial sources are 0.256 and 0.756 mSv, respectively, with a total value of 1.012 mSv

  3. Scalable Continuous Range Monitoring of Moving Objects in Symbolic Indoor Space

    DEFF Research Database (Denmark)

    Yang, Bin; Lu, Hua; Jensen, Christian Søndergaard

    2009-01-01

    Indoor spaces accommodate large populations of individuals. The continuous range monitoring of such objects can be used as a foundation for a wide variety of applications, e.g., space planning, way finding, and security. Indoor space differs from outdoor space in that symbolic locations, e...

  4. Indoor Environmental Factors and Occurrence of Lung Function Decline in Adult Residents in Summer in Southwest China.

    Science.gov (United States)

    Jie, Yu; Kebin, Li; Yin, Tang; Jie, Xu

    2016-11-01

    There is conflicting reports on the respiratory health effects of indoor risk factor exposure. The aim of this study was to assess the association of indoor environmental factors to pulmonary function in an adult population in Zunyi City of Southwest China. Between July and Sep 2012, we conducted a cross-sectional survey of people aged ≥18 yr in 11 inner-city areas of Zunyi. Data on asthma and asthma-related symptoms and selected home environmental factors were assessed by questionnaire. Lung function measurements, including FVC, FEV 1 , FEV 1 /FVC and PEFR, were assessed and compared. Exposure to indoor and outdoor PM 2.5 was monitored by measurement of PM 2.5 emission relative concentration. Cooking oil fumes, environmental tobacco smoke (ETS) and coal fuel use were associated with impaired lung function among adults in summer season ( P oil fumes, pest in kitchen, mosquito repellent, fluffy blanket, pets, visible mold in bedroom and ETS (active and passive smoking) tended to exhibit greater decreases in FVC, FEV 1 and PEFR values compared with their non-exposed counterparts ( P kitchen, sleeping area and outdoor were 486.0cpm, 463.0cpm and 459.0cpm, respectively. PM 2.5 relative concentration in indoor kitchen and sleeping area were significant higher than outdoor ( P kitchen, sleeping area risk factors and ETS exposure and a reduction in lung function in summer was revealed in Zunyi.

  5. Behaviors of radon in indoor environment

    International Nuclear Information System (INIS)

    Mochizuki, Sadamu; Shimo, Michikuni.

    1987-01-01

    The source of radon ( 222 Rn) in the atmosphere is radioactive nuclide, uranium ( 238 U), which exists fairly common throughout the earth's crust. Radium ( 226 Ra) descended from uranium produce radon ( 222 Rn) of noble gas by decay. After formation in the ground, radon diffuses into the atmosphere. Without exception radon decay products are heavy metals which soon become attached to natural aerosols. Therefore, radon and its daughters (decay products) appear also in indoor environment, and generally, their concentration levels become higher than that of outdoor air due to build-up effects in the closed indoor environments. With the progress of the study on the influence of radon and its daughers on human health, it has become clear that they act effectively as an exciting cause of lung cancer. So, the study on the risk evaluation of them in room air has become to be very important. Concequently, the behaviors of radon and its daughters in indoor environment, first of all, should be studied in detail for the accurate estimation of the risk caused by them. In this special edition, fundamental characteristics of radon and its daughters, some measuring methods, theoretical considerations and some observational evidences obtained from various circumstances of indoor environment are described inorder to grasp and understand the behaviors of radon and its daughters in the indoor environment. (author)

  6. Chemical characterization of outdoor and subway fine (PM(2.5-1.0)) and coarse (PM(10-2.5)) particulate matter in Seoul (Korea) by computer-controlled scanning electron microscopy (CCSEM).

    Science.gov (United States)

    Byeon, Sang-Hoon; Willis, Robert; Peters, Thomas M

    2015-02-13

    Outdoor and indoor (subway) samples were collected by passive sampling in urban Seoul (Korea) and analyzed with computer-controlled scanning electron microscopy coupled with energy dispersive x-ray spectroscopy (CCSEM-EDX). Soil/road dust particles accounted for 42%-60% (by weight) of fine particulate matter larger than 1 µm (PM(2.5-1.0)) in outdoor samples and 18% of PM2.5-1.0 in subway samples. Iron-containing particles accounted for only 3%-6% in outdoor samples but 69% in subway samples. Qualitatively similar results were found for coarse particulate matter (PM(10-2.5)) with soil/road dust particles dominating outdoor samples (66%-83%) and iron-containing particles contributing most to subway PM(10-2.5) (44%). As expected, soil/road dust particles comprised a greater mass fraction of PM(10-2.5) than PM(2.5-1.0). Also as expected, the mass fraction of iron-containing particles was substantially less in PM(10-2.5) than in PM(2.5-1.0). Results of this study are consistent with known emission sources in the area and with previous studies, which showed high concentrations of iron-containing particles in the subway compared to outdoor sites. Thus, passive sampling with CCSEM-EDX offers an inexpensive means to assess PM(2.5-1.0) and PM(10-2.5) simultaneously and by composition at multiple locations.

  7. Indoor radon level measurements in Iran using AEOI passive dosimeters

    International Nuclear Information System (INIS)

    Sohrabi, M.; Solaymanian, A.R.

    1988-01-01

    A passive radon diffusion dosimeter was developed at the RPD of AEOI for nationwide indoor radon level measurements. Several parameters of the dosimeter were studied. Radon levels were determined in about 250 houses in Ramsar (a high natural radiation area), Tehran, Babolsar and Gonabad. In this paper, the results of some dosimeter parameters as well as radon levels in indoor air are reported

  8. Indoor air quality in energy-efficient dwellings: Levels and sources of pollutants.

    Science.gov (United States)

    Derbez, M; Wyart, G; Le Ponner, E; Ramalho, O; Ribéron, J; Mandin, C

    2018-03-01

    Worldwide, public policies are promoting energy-efficient buildings and accelerating the thermal renovation of existing buildings. The effects of these changes on the indoor air quality (IAQ) in these buildings remain insufficiently understood. In this context, a field study was conducted in 72 energy-efficient dwellings to describe the pollutants known to be associated with health concerns. Measured parameters included the concentrations of 19 volatile organic compounds and aldehydes, nitrogen dioxide, particulate matter (PM 2.5 ), radon, temperature, and relative humidity. The air stuffiness index and night-time air exchange rate were calculated from the monitored carbon dioxide (CO 2 ) concentrations. Indoor and outdoor measurements were performed at each dwelling during 1 week in each of the two following seasons: heating and non-heating. Moreover, questionnaires were completed by the occupants to characterize the building, equipment, household, and occupants' habits. Perspective on our results was provided by previous measurements made in low-energy European dwellings. Statistical comparisons with the French housing stock and a pilot study showed higher concentrations of terpenes, that is, alpha-pinene and limonene, and hexaldehyde in our study than in previous studies. Alpha-pinene and hexaldehyde are emitted by wood or wood-based products used for the construction, insulation, decoration, and furnishings of the dwellings, whereas limonene is more associated with discontinuous sources related to human activities. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. THERMAL ADAPTATION, CAMPUS GREENING AND OUTDOOR USE IN LAUTECH CAMPUS, OGBOMOSO, NIGERIA

    Directory of Open Access Journals (Sweden)

    Joseph Adeniran ADEDEJI

    2011-12-01

    Full Text Available The interwoven relationship between the use of indoors and outdoors in the tropics as means of thermal adaptation has long been recognized. In the case of outdoors, this is achieved by green intervention of shading trees as adaptive mechanisms through behavioural thermoregulation. Unfortunately, the indoor academic spaces of LAUTECH campus was not provided with necessary outdoor academic learning environment in the general site planning of the campus for use at peak indoor thermal dissatisfaction period considering the tropical climatic setting of the university. The students’ departmental and faculty associations tried to provide parks for themselves as alternatives which on casual observation are of substandard quality and poorly maintained because of lack of institutional coordination and low funding. This study examined the quality and use of these parks for thermal comfort through behavioral adjustment from subjective field evidence with the goal of improvement. To achieve this, twelve parks were selected within the campus. Questionnaires containing use and quality variables were administered randomly upon 160 users of these parks. The data obtained was subjected to descriptive statistical analysis. Results show that the quality of the parks, weather condition, period of the day, and personal psychological reasons of users has great influence on the use of the parks. The study concludes with policy recommendations on improvement of the quality of the parks and the campus outdoors and greenery in general.

  10. Effect of efficient supply of pure O{sub 2} concentrated by PSA-type O{sub 2} separator on improvement of indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Han, Gi Bo; Jang, Jung Hee; Choi, Changsik [Institute for Advanced Engineering, Yongin (Korea, Republic of); Lee, Tae Jin [School of Chemical Engineering Yeungnam University, Gyeongsan (Korea, Republic of)

    2016-04-15

    To minimize the cost and loss rate of energy artificial room ventilation system, the O{sub 2} separator was suggested for the flow of the excessive ventilation amount between indoor and outdoor because the pure O{sub 2} separated and concentrated by the O{sub 2} separator can be supplied with the ventilation amount minimized. How the O{sub 2} separator applies to ventilation and its operation characteristics were investigated by controlling under various conditions as well as the operation conditions optimized required for indoor air quality such as the concentration of CO{sub 2} and O{sub 2}. Consequently, it was known that the O{sub 2} concentration was increased; however, the increase of the CO{sub 2} concentration was suppressed by the sufficient supply of O{sub 2} concentrated from the storage tank into the room despite the two persons’ breathing in the room having an inner volume of about 56m{sup 3}. Consequently, it was concluded that the supply system of the concentrated O{sub 2} which was stored into the tank after the production with the O{sub 2} separator can be applied to the room ventilation system for the improvement of the indoor air quality.

  11. Improving indoor air quality and thermal comfort in office building by using combination filters

    Science.gov (United States)

    Kabrein, H.; Yusof, M. Z. M.; Hariri, A.; Leman, A. M.; Afandi, A.

    2017-09-01

    Poor indoor air quality and thermal comfort condition in the workspace affected the occupants’ health and work productivity, especially when adapting the recirculation of air in heating ventilation and air-conditioning (HVAC) system. The recirculation of air was implemented in this study by mixing the circulated returned indoor air with the outdoor fresh air. The aims of this study are to assess the indoor thermal comfort and indoor air quality (IAQ) in the office buildings, equipped with combination filters. The air filtration technique consisting minimum efficiency reporting value (MERV) filter and activated carbon fiber (ACF) filter, located before the fan coil units. The findings of the study show that the technique of mixing recirculation air with the fresh air through the combination filters met the recommended thermal comfort condition in the workspace. Furthermore, the result of the post-occupancy evaluation (POE) and the environmental measurements comply with the ASHRAE 55 standard. In addition, the level of CO2 concentration continued to decrease during the period of the measurement.

  12. ‘Getting Children Outdoors again’ - Outdoor Play for children in a rural North West of Ireland setting: A civic engagement Project

    OpenAIRE

    McGonagle, Michelle

    2017-01-01

    Children’s’ Outdoor play nowadays is the preferred approach to playing indoors which has become a constant focus of influences and powers of technology. Children spend hours on social media sites, isolated playing video games and lost in technologically powered screens (Larson et al, 2011). As a results of this disengagement with outdoors activities, children fall victims to many problems including obesity, social exclusion, and in some cases behavioural issues Fresh air and exercise are prob...

  13. Indoor pollutant levels from the use of unvented natural gas fireplaces in Boulder, Colorado.

    Science.gov (United States)

    Dutton, S J; Hannigan, M P; Miller, S L

    2001-12-01

    High CO and NO2 concentrations have been documented in homes with unvented combustion appliances, such as natural gas fireplaces. In addition, polycyclic aromatic hydrocarbons (PAH) are emitted from incomplete natural gas combustion. The acute health risks of CO and NO2 exposure have been well established for the general population and for certain high-risk groups, including infants, the elderly, and people with heart disease or asthma. Health effects from PAH exposure are less well known, but may include increased risk of cancer. We monitored CO emissions during the operation of unvented natural gas fireplaces in two residences in Boulder, CO, at various times between 1997 and 2000. During 1999, we expanded our tests to include measurements of NO2 and PAH. Results show significant pollutant accumulation indoors when the fireplaces were used for extended periods of time. In one case, CO concentrations greater than 100 ppm accumulated in under 2 hr of operation; a person at rest exposed for 10 hr to this environment would get a mild case of CO poisoning with an estimated 10% carboxyhemoglobin level. Appreciable NO2 concentrations were also detected, with a 4-hr time average reaching 0.36 ppm. Similar time-average total PAH concentrations reached 35 ng/m3. The results of this study provide preliminary insights to potential indoor air quality problems in homes operating unvented natural gas fireplaces in Boulder.

  14. Outdoor activity and myopia progression in 4-year follow-up of Chinese primary school children: The Beijing Children Eye Study.

    Directory of Open Access Journals (Sweden)

    Yin Guo

    Full Text Available To investigate factors associated with ocular axial elongation and myopia progression during a 4-year follow-up in primary school children in Beijing.This school-based study included 382 grade-1 children at baseline in 2011 (age:6.3±0.4 years with 305 (79.8% returning for the follow-up examination in 2015. At baseline and in yearly follow-up examinations, the children underwent a comprehensive eye examination including auto-refractometry, ocular biometry with measurement of axial length, and fundus photography. The parents underwent a standardized interview.During the study period, the mean axial length elongated by 1.15±0.56mm in boys and 1.10±0.63mm in girls. At baseline and at the end of follow-up, axial length was significantly (P<0.001 longer in boys, with no difference (P = 0.50 between genders in axial elongation. In multivariate analysis, greater axial elongation was associated (regression coefficient r2:0.15 with less time spent outdoors (P = 0.004; standardized coefficient beta: -0.22, more time spent indoors with studying (P = 0.02; beta: 0.18 and paternal myopia (P = 0.03; beta: 0.16. Larger increases in the axial length/anterior corneal curvature (AL/CC ratio were associated (r2:0.09 with less time spent outdoors (PP = 0.003; beta: -0.22 and maternal myopia (PP = 0.02; beta: 0.18.Myopic axial elongation during a 4-year follow-up was associated with shorter time spent outdoors and longer time spent indoors studying and with parental myopia. Other factors such as level of paternal education, family income, gender and region of habitation were significantly associated with axial elongation and with myopia progression only in univariate analysis.

  15. House-dust mites in our homes are a contamination from outdoor sources.

    Science.gov (United States)

    Hallas, Thorkil E

    2010-05-01

    Avoidance advices for house-dust mite sensitized persons are currently based upon the idea, that the mites (Dermatophagoides spp.) are part of the indoor fauna. A closer look at development stages in the house-dust samples shows, however, that only the mites' active stages are present there and that the stages between them, the inactive moulting stages, are absent. Therefore the mites probably do not carry out their life cycles in our dwellings, but are more likely contaminations from the open. Findings of low level concentrations can be explained by mites coming from outdoors and sedimented in accordance with known physical laws. The occasional finding of higher concentrations is the result of synchronized populations of the mites developing outdoors and being passively transported into our homes by wind and dust. The hypothesis explains why we find mites in our homes but nonetheless have no effect of avoidance measures. The verification of the entire hypothesis or part of it may have great impact on the management of the disease house-dust mite allergy.

  16. A Pedestrian Approach to Indoor Temperature Distribution Prediction of a Passive Solar Energy Efficient House

    Directory of Open Access Journals (Sweden)

    Golden Makaka

    2015-01-01

    Full Text Available With the increase in energy consumption by buildings in keeping the indoor environment within the comfort levels and the ever increase of energy price there is need to design buildings that require minimal energy to keep the indoor environment within the comfort levels. There is need to predict the indoor temperature during the design stage. In this paper a statistical indoor temperature prediction model was developed. A passive solar house was constructed; thermal behaviour was simulated using ECOTECT and DOE computer software. The thermal behaviour of the house was monitored for a year. The indoor temperature was observed to be in the comfort level for 85% of the total time monitored. The simulation results were compared with the measured results and those from the prediction model. The statistical prediction model was found to agree (95% with the measured results. Simulation results were observed to agree (96% with the statistical prediction model. Modeled indoor temperature was most sensitive to the outdoor temperatures variations. The daily mean peak ones were found to be more pronounced in summer (5% than in winter (4%. The developed model can be used to predict the instantaneous indoor temperature for a specific house design.

  17. The influences of ambient particle composition and size on particle infiltration in Los Angeles, CA, residences.

    Science.gov (United States)

    Sarnat, Stefanie Ebelt; Coull, Brent A; Ruiz, Pablo A; Koutrakis, Petros; Suh, Helen H

    2006-02-01

    Particle infiltration is a key determinant of the indoor concentrations of ambient particles. Few studies have examined the influence of particle composition on infiltration, particularly in areas with high concentrations of volatile particles, such as ammonium nitrate (NH4NO3). A comprehensive indoor monitoring study was conducted in 17 Los Angeles-area homes. As part of this study, indoor/outdoor concentration ratios during overnight (nonindoor source) periods were used to estimate the fraction of ambient particles remaining airborne indoors, or the particle infiltration factor (FINF), for fine particles (PM2.5), its nonvolatile (i.e., black carbon [BC]) and volatile (i.e., nitrate [NO3-]) components, and particle sizes ranging between 0.02 and 10 microm. FINF was highest for BC (median = 0.84) and lowest for NO3- (median = 0.18). The low FINF for NO3- was likely because of volatilization of NO3- particles once indoors, in addition to depositional losses upon building entry. The FINF for PM2.5 (median = 0.48) fell between those for BC and NO3-, reflecting the contributions of both particle components to PM25. FINF varied with particle size, air-exchange rate, and outdoor NO3- concentrations. The FINF for particles between 0.7 and 2 microm in size was considerably lower during periods of high as compared with low outdoor NO3- concentrations, suggesting that outdoor NO3- particles were of this size. This study demonstrates that infiltration of PM2.5 varies by particle component and is lowest for volatile species, such as NH4NO3. Our results suggest that volatile particle components may influence the ability for outdoor PM concentrations to represent indoor and, thus, personal exposures to particles of ambient origin, because volatilization of these particles causes the composition of PM2.5 to differ indoors and outdoors. Consequently, particle composition likely influences observed epidemiologic relationships based on outdoor PM concentrations, especially in areas

  18. Indoor Air Quality in Schools.

    Science.gov (United States)

    Torres, Vincent M.

    Asserting that the air quality inside schools is often worse than outdoor pollution, leading to various health complaints and loss of productivity, this paper details factors contributing to schools' indoor air quality. These include the design, operation, and maintenance of heating, ventilating, and air conditioning (HVAC) systems; building…

  19. A Pilot Study to Understand the Variation in Indoor Air Quality in Different Economic Zones of Delhi University

    Science.gov (United States)

    Garg, Abhinav; Ghosh, Chirashree

    Today, one of the most grave environmental health problems being faced by the urban population is the poor air quality one breathes in. To testify the above statement, the recent survey report, World health statistics (WHO, 2012) reflects the fact that childhood mortality ratio from acute respiratory infection is one of the top leading causes of death in developing countries like India. Urban areas have a complex social stratification which ultimately results in forming different urban economic zones. This research attempts to understand the Indoor Air Quality (IAQ) by taking into consideration different lifestyle of occupants inhabiting these economic zones. The Study tries to evaluate the outdoor and indoor air quality by understanding the variation of selected pollutants (SPM, SOx, NOx) for the duration of four months - from October, 2012-January, 2013. For this, three economic zones (EZ) of Delhi University’s North Campus, were selected - Urban Slum (EZ I), Clerical (EZ II) and Faculty residence (EZ III). The statistical study indicates that Urban Slum (EZ I) was the most polluted site reporting maximum concentration of outdoor pollutants, whereas no significant difference in pollution load was observed in EZ II and EZ III. Further, the indoor air quality was evaluated by quantifying the indoor and outdoor pollution concentration ratios that shows EZ III have most inferior indoor air quality, followed by EZ I and EZ II. Moreover, it was also observed that ratio (phenomenon of infiltration) was dominant at the EZ II but was low for the EZ I and EZ III. With the evidence of high Indoor air pollution, the risk of pulmonary diseases and respiratory infections also increases, calling for an urgent requisite for making reforms to improve IAQ. Key words: Urban Area, Slum, IAQ, SOx, NOx, SPM

  20. Indoor Air Pollution

    OpenAIRE

    Kirk R. Smith

    2003-01-01

    Outdoor air pollution in developing-country cities is difficult to overlook. Indoor air pollution caused by burning such traditional fuels as wood, crop residues, and dung is less evident, yet it is responsible for a significant part of country and global disease burdens. The main groups affected are poor women and children in rural areas and urban slums as they go about their daily activi...