WorldWideScience

Sample records for indoor atmospheric iron

  1. Indoor atmospheric corrosion of historical ferrous alloys. System characterisation, mechanisms and modelling discussion

    International Nuclear Information System (INIS)

    Monnier, J.

    2008-12-01

    Understanding the mechanisms of indoor atmospheric corrosion in iron alloys is of primary importance in several fields, including for the conservation of Middle Ages monuments or the long term storage of nuclear waste. In this research, a double approach was developed, combining fine characterisation of corrosion systems and design of experiments to answers specific questions related to mechanisms understanding. Iron indoor atmospheric corrosion was investigated on samples coming from the reinforcing chain of the Amiens cathedral (15. century). In the first stage, the corrosion system has been extensively characterised from the macroscopic to the nano-metric scale. In particular, structural micro-analysis (μ-Raman, μ-XRD, μ-XAS) has been used to locate, identify and quantify the oxidised phases. Rust layers are composed of a matrix of nano-metric goethite, with low quantities of lepidocrocite and akaganeite mostly located in the extern part of the corrosion system. In addition, clear marblings are dispersed in the matrix, which are sometimes connected with the metal core. Although these may contain maghemite, these marblings are generally made of ferri-hydrite/feroxyhite phases. In the second stage, specific experiments have been carried out in an unsaturated marked medium to locate oxygen reduction sites in the rust layers. Several cases were evidenced, depending on the rust layer morphology. In addition, reduction processes of model phases have been studied in situ, using an electrochemical cell coupled with structural characterisation techniques. This combination highlighted the influence of reduction mode and pH on the type of reduced phase formed. From the obtained results, several mechanisms are proposed to explain the long term indoor atmospheric corrosion of iron, including rust layers morphology and phases properties. The different hypotheses have been integrated in a proposed method to diagnosis ancient ferrous systems stability. These hypotheses also

  2. Control of radon and its progeny concentration in indoor atmosphere

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subbaramu, M.C.

    1986-01-01

    Exposure to radon daughter concentration in indoor atmosphere can result in a significant risk to the general public. There are two generally used methods for the control of radon and progeny concentration in the indoor atmosphere, namely restriction of radon entry and reduction of indoor radon and its progeny concentration by ventilation or by air cleaning. Predominant radon entry process in most of the dwellings appears to be by pressure driven flow of soil gas through cracks or other openings in the basement slab or subfloors. Sealing these openings or ventilation of the subslab or subfloor space are the methods for reducing the radon entry rates. Indoor radon concentration can also be reduced by increasing the ventilation and by using charcoal filters for the removal of radon gas in indoor air by absorption. Concentration of radon progeny, which are responsible for most of the health risks associatd with radon exposure can also be controlled by the use of electrostatic or mechanical filters. This study describes briefly the above control strategies used for reducing the inhalation doses to persons in dwellings. (author). 9 refs., 2 tables

  3. Atmospheric processing of iron carried by mineral dust

    Directory of Open Access Journals (Sweden)

    S. Nickovic

    2013-09-01

    Full Text Available Nutrification of the open ocean originates mainly from deposited aerosol in which the bio-avaliable iron is likely to be an important factor. The relatively insoluble iron in dust from arid soils becomes more soluble after atmospheric processing and, through its deposition in the ocean, could contribute to marine primary production. To numerically simulate the atmospheric route of iron from desert sources to sinks in the ocean, we developed a regional atmospheric dust-iron model that included parameterization of the transformation of iron to a soluble form caused by dust mineralogy, cloud processes and solar radiation. When compared with field data on the aerosol iron, which were collected during several Atlantic cruises, the results from the higher-resolution simulation experiments showed that the model was capable of reproducing the major observed patterns.

  4. Ecological aspects of Moessbauer study of iron-containing atmospheric aerosols

    International Nuclear Information System (INIS)

    Kopcewicz, B.; Kopcewicz, M.

    2000-01-01

    Moessbauer spectroscopy was applied to analyze the iron compounds in atmospheric aerosol. Seasonal variations of iron concentration in atmospheric air measured over twenty years in Poland are discussed. It was observed that the concentration of iron sulfides (FeS, FeS 2 ) related to coal combustion dropped significantly, however, concentration of iron oxides and iron oxyhydroxides related to fuel combustion increased

  5. Indoor-atmospheric radon-related radioactivity affected by a change of ventilation strategy

    International Nuclear Information System (INIS)

    Kobayashi, Tuneo

    2006-01-01

    The present author has kept observation for concentrations of atmospheric radon, radon progeny and thoron progeny for several years at the campus of Fukushima Medical University. Accidentally, in the midst of an observation term, i.e., February 2005, the facility management group of the university changed a strategy for the manner of ventilation, probably because of a recession: tidy everyday ventilation of 7:30-24:00 into shortened weekday ventilation of 8:00-21:00 with weekend halts. This change of ventilation manner brought a clear alteration for the concentrations of radon-related natural radioactivity in indoor air. The present paper concerns an investigation of the effect of the ventilation strategy on the indoor-atmospheric radon-related radioactivity. (author)

  6. Effect of atmospheric organic complexation on iron-bearing dust solubility

    Directory of Open Access Journals (Sweden)

    R. Paris

    2013-05-01

    Full Text Available Recent studies reported that the effect of organic complexation may be a potentially important process to be considered by models estimating atmospheric iron flux to the ocean. In this study, we investigated this process effect by a series of dissolution experiments on iron-bearing dust in the presence or the absence of various organic compounds (acetate, formate, oxalate, malonate, succinate, glutarate, glycolate, lactate, tartrate and humic acid as an analogue of humic like substances, HULIS typically found in atmospheric waters. Only 4 of tested organic ligands (oxalate, malonate, tartrate and humic acid caused an enhancement of iron solubility which was associated with an increase of dissolved Fe(II concentrations. For all of these organic ligands, a positive linear dependence of iron solubility to organic concentrations was observed and showed that the extent of organic complexation on iron solubility decreased in the following order: oxalate >malonate = tartrate > humic acid. This was attributed to the ability of electron donors of organic ligands and implies a reductive ligand-promoted dissolution. This study confirms that among the known atmospheric organic binding ligands of Fe, oxalate is the most effective ligand promoting dust iron solubility and showed, for the first time, the potential effect of HULIS on iron dissolution under atmospheric conditions.

  7. Control methods of radon and its progeny concentration in indoor atmosphere

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subba Ramu, M.C.

    1990-01-01

    Exposure to radon-222 and its progeny in indoor atmosphere can result in significant inhalation risk to the population particularly to those living in houses with much higher levels of Rn. There are three methods generally used for the control of Rn and its progeny concentration in the indoor environment: (1) restricting the radon entry, (2) reduction of indoor radon concentration by ventilation or by aircleaning and (3) removal of airborne radon progeny by aerosol reduction. Prominent process of radon entry in most of the residence appears to be the pressure driven flow of soil gas through cracks or through other openings in the basements slab or subfloor. Sealing off these openings or ventilation of the slab or subfloor spaces are the methods of reducing the radon entry rate. Indoor radon progeny levels can also be reduced by decreasing the aerosol load in the dwellings. The results of a few experiments carried out to study the reduction in the working level concentration of radon, by decreasing the aerosol load are discussed in this paper. (author). 9 tabs., 8 figs., 37 refs

  8. Three-dimensional vapor intrusion modeling approach that combines wind and stack effects on indoor, atmospheric, and subsurface domains.

    Science.gov (United States)

    Shirazi, Elham; Pennell, Kelly G

    2017-12-13

    Vapor intrusion (IV) exposure risks are difficult to characterize due to the role of atmospheric, building and subsurface processes. This study presents a three-dimensional VI model that extends the common subsurface fate and transport equations to incorporate wind and stack effects on indoor air pressure, building air exchange rate (AER) and indoor contaminant concentration to improve VI exposure risk estimates. The model incorporates three modeling programs: (1) COMSOL Multiphysics to model subsurface fate and transport processes, (2) CFD0 to model atmospheric air flow around the building, and (3) CONTAM to model indoor air quality. The combined VI model predicts AER values, zonal indoor air pressures and zonal indoor air contaminant concentrations as a function of wind speed, wind direction and outdoor and indoor temperature. Steady state modeling results for a single-story building with a basement demonstrate that wind speed, wind direction and opening locations in a building play important roles in changing the AER, indoor air pressure, and indoor air contaminant concentration. Calculated indoor air pressures ranged from approximately -10 Pa to +4 Pa depending on weather conditions and building characteristics. AER values, mass entry rates and indoor air concentrations vary depending on weather conditions and building characteristics. The presented modeling approach can be used to investigate the relationship between building features, AER, building pressures, soil gas concentrations, indoor air concentrations and VI exposure risks.

  9. Coal fly ash as a source of iron in atmospheric dust.

    Science.gov (United States)

    Chen, Haihan; Laskin, Alexander; Baltrusaitis, Jonas; Gorski, Christopher A; Scherer, Michelle M; Grassian, Vicki H

    2012-02-21

    Anthropogenic coal fly ash (FA) aerosol may represent a significant source of bioavailable iron in the open ocean. Few measurements have been made that compare the solubility of atmospheric iron from anthropogenic aerosols and other sources. We report here an investigation of iron dissolution for three FA samples in acidic aqueous solutions and compare the solubilities with that of Arizona test dust (AZTD), a reference material for mineral dust. The effects of pH, simulated cloud processing, and solar radiation on iron solubility have been explored. Similar to previously reported results on mineral dust, iron in aluminosilicate phases provides the predominant component of dissolved iron. Iron solubility of FA is substantially higher than of the crystalline minerals comprising AZTD. Simulated atmospheric processing elevates iron solubility due to significant changes in the morphology of aluminosilicate glass, a dominant material in FA particles. Iron is continuously released into the aqueous solution as FA particles break up into smaller fragments. These results suggest that the assessment of dissolved atmospheric iron deposition fluxes and their effect on the biogeochemistry at the ocean surface should be constrained by the source, environmental pH, iron speciation, and solar radiation.

  10. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Hopke, P.K.

    1992-07-01

    This report covers the second year of the 28 month grant current grant to Clarkson University to study the chemical and physical behavior of the polonium 218 atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and it dose to the cells in the respiratory tract are to be fully assessed. Two areas of radon progeny behavior are being pursued; laboratory studies under controlled conditions to better understand the fundamental physical and chemical process that affect the progeny's atmospheric behavior and studies in actual indoor environments to develop a better assessment of the exposure of the occupants of that space to the size and concentration of the indoor radioactive aerosol. This report describes the progress toward achieving these objectives.

  11. Influence of Atmospheric Processes on the Solubility and Composition of Iron in Saharan Dust.

    Science.gov (United States)

    Longo, Amelia F; Feng, Yan; Lai, Barry; Landing, William M; Shelley, Rachel U; Nenes, Athanasios; Mihalopoulos, Nikolaos; Violaki, Kalliopi; Ingall, Ellery D

    2016-07-05

    Aerosol iron was examined in Saharan dust plumes using a combination of iron near-edge X-ray absorption spectroscopy and wet-chemical techniques. Aerosol samples were collected at three sites located in the Mediterranean, the Atlantic, and Bermuda to characterize iron at different atmospheric transport lengths and time scales. Iron(III) oxides were a component of aerosols at all sampling sites and dominated the aerosol iron in Mediterranean samples. In Atlantic samples, iron(II and III) sulfate, iron(III) phosphate, and iron(II) silicates were also contributors to aerosol composition. With increased atmospheric transport time, iron(II) sulfates are found to become more abundant, aerosol iron oxidation state became more reduced, and aerosol acidity increased. Atmospheric processing including acidic reactions and photoreduction likely influence the form of iron minerals and oxidation state in Saharan dust aerosols and contribute to increases in aerosol-iron solubility.

  12. A Global Atmospheric Model of Meteoric Iron

    Science.gov (United States)

    Feng, Wuhu; Marsh, Daniel R.; Chipperfield, Martyn P.; Janches, Diego; Hoffner, Josef; Yi, Fan; Plane, John M. C.

    2013-01-01

    The first global model of meteoric iron in the atmosphere (WACCM-Fe) has been developed by combining three components: the Whole Atmosphere Community Climate Model (WACCM), a description of the neutral and ion-molecule chemistry of iron in the mesosphere and lower thermosphere (MLT), and a treatment of the injection of meteoric constituents into the atmosphere. The iron chemistry treats seven neutral and four ionized iron containing species with 30 neutral and ion-molecule reactions. The meteoric input function (MIF), which describes the injection of Fe as a function of height, latitude, and day, is precalculated from an astronomical model coupled to a chemical meteoric ablation model (CABMOD). This newly developed WACCM-Fe model has been evaluated against a number of available ground-based lidar observations and performs well in simulating the mesospheric atomic Fe layer. The model reproduces the strong positive correlation of temperature and Fe density around the Fe layer peak and the large anticorrelation around 100 km. The diurnal tide has a significant effect in the middle of the layer, and the model also captures well the observed seasonal variations. However, the model overestimates the peak Fe+ concentration compared with the limited rocket-borne mass spectrometer data available, although good agreement on the ion layer underside can be obtained by adjusting the rate coefficients for dissociative recombination of Fe-molecular ions with electrons. Sensitivity experiments with the same chemistry in a 1-D model are used to highlight significant remaining uncertainties in reaction rate coefficients, and to explore the dependence of the total Fe abundance on the MIF and rate of vertical transport.

  13. Atmospheric processing of combustion aerosols as a source of soluble iron to the open ocean

    OpenAIRE

    伊藤, 彰記; ITO, Akinori

    2015-01-01

    The majority of bioavailable iron (Fe) from the atmosphere is delivered from arid and semiarid regions to the oceans because the global deposition of iron from combustion sources is small compared with that from mineral dust. Atmospheric processing of mineral aerosols by inorganic and organic acids from anthropogenic and natural sources has been shown to increase the iron solubility of soils (initially < 0.5%) up to about 10%. On the other hand, atmospheric observations have shown that iron i...

  14. Quantification of trace elements and speciation of iron in atmospheric particulate matter

    Science.gov (United States)

    Upadhyay, Nabin

    Trace metal species play important roles in atmospheric redox processes and in the generation of oxidants in cloud systems. The chemical impact of these elements on atmospheric and cloud chemistry is dependent on their occurrence, solubility and speciation. First, analytical protocols have been developed to determine trace elements in particulate matter samples collected for carbonaceous analysis. The validated novel protocols were applied to the determination of trace elements in particulate samples collected in the remote marine atmosphere and urban areas in Arizona to study air pollution issues. The second part of this work investigates on solubility and speciation in environmental samples. A detailed study on the impact of the nature and strength of buffer solutions on solubility and speciation of iron lead to a robust protocol, allowing for comparative measurements in matrices representative of cloud water conditions. Application of this protocol to samples from different environments showed low iron solubility (less than 1%) in dust-impacted events and higher solubility (5%) in anthropogenically impacted urban samples. In most cases, Fe(II) was the dominant oxidation state in the soluble fraction of iron. The analytical protocol was then applied to investigate iron processing by fogs. Field observations showed that only a small fraction (1%) of iron was scavenged by fog droplets for which each of the soluble and insoluble fraction were similar. A coarse time resolution limited detailed insights into redox cycling within fog system. Overall results suggested that the major iron species in the droplets was Fe(1I) (80% of soluble iron). Finally, the occurrence and sources of emerging organic pollutants in the urban atmosphere were investigated. Synthetic musk species are ubiquitous in the urban environment (less than 5 ng m-3) and investigations at wastewater treatment plants showed that wastewater aeration basins emit a substantial amount of these species to

  15. Oxygen in the Martian atmosphere: Regulation of PO2 by the deposition of iron formations on Mars

    Science.gov (United States)

    Burns, Roger G.

    1992-01-01

    During Earth's early history, and prior to the evolution of its present day oxygenated atmosphere, extensive iron rich siliceous sedimentary rocks were deposited, consisting of alternating layers of silica (chert) and iron oxide minerals (hematite and magnetite). The banding in iron formations recorded changes of atmosphere-hydrosphere interactions near sea level in the ancient ocean, which induced the oxidation of dissolved ferrous iron, precipitation of insoluble ferric oxides and silica, and regulation of oxygen in Earth's early atmosphere. Similarities between the Archean Earth and the composition of the present day atmosphere on Mars, together with the pervasive presence of ferric oxides in the Martian regolith suggest that iron formation might also have been deposited on Mars and influenced the oxygen content of the Martian atmosphere. Such a possibility is discussed here with a view to assessing whether the oxygen content of the Martian atmosphere has been regulated by the chemical precipitation of iron formations on Mars.

  16. Atmospheric and marine controls on aerosol iron solubility in seawater

    OpenAIRE

    Baker, A.R.; Croot, Peter

    2010-01-01

    The fraction of atmospherically deposited iron which dissolves in seawater, or becomes available to phytoplankton for growth, is a key determinant of primary productivity in many open ocean regions. As such this parameter plays an important part in the global oceanic cycles of iron and carbon, and yet the factors that control iron dissolution from aerosol are very poorly understood. In this manuscript we seek to synthesise the available knowledge of these factors, which operate in the atmos...

  17. Reduction Behaviors of Carbon Composite Iron Oxide Briquette Under Oxidation Atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ki-Woo; Kim, Kang-Min; Kwon, Jae-Hong; Han, Jeong-Whan [Inha University, Incheon (Korea, Republic of); Son, Sang-Han [POSCO, Pohang (Korea, Republic of)

    2017-01-15

    The carbon composite iron oxide briquette (CCB) is considered a potential solution to the upcoming use of low grade iron resources in the ironmaking process. CCB is able to reduce raw material cost by enabling the use of low grade powdered iron ores and coal. Additionally, the fast reduction of iron oxides by direct contact with coal can be utilized. In this study, the reduction behaviors of CCB were investigated in the temperature range of 200-1200 ℃ under oxidizing atmosphere. Briquettes were prepared by mixing iron ore and coal in a weight ratio of 8:2. Then reduction experiments were carried out in a mixed gas atmosphere of N{sub 2}, O{sub 2}, and CO{sub 2}. Compressive strength tests and quantitative analysis were performed by taking samples at each target temperature. In addition, the reduction degree depending on the reaction time was evaluated by off-gas analysis during the reduction test. It was found that the compressive strength and the metallization degree of the reduced briquettes increased with increases in the reaction temperature and holding time. However, it tended to decrease when the re-oxidation phenomenon was caused by injected oxygen. The degree of reduction reached a maximum value in 26 minutes. Therefore, the re-oxidation phenomenon becomes dominant after 26 minutes.

  18. Psychotropic substances in indoor environments.

    Science.gov (United States)

    Cecinato, Angelo; Romagnoli, Paola; Perilli, Mattia; Patriarca, Claudia; Balducci, Catia

    2014-10-01

    The presence of drugs in outdoor air has been established, but few investigations have been conducted indoors. This study focused on psychotropic substances (PSs) at three schools, four homes and one office in Rome, Italy. The indoor drug concentrations and the relationships with the outdoor atmosphere were investigated. The optimised monitoring procedure allowed for the determination of cocaine, cannabinoids and particulate fractions of nicotine and caffeine. In-field experiments were performed during the winter, spring and summer seasons. Psychotropic substances were observed in all indoor locations. The indoor concentrations often exceeded those recorded both outdoors at the same sites and at the atmospheric pollution control network stations, indicating that the drugs were released into the air at the inside sites or were more persistent. During winter, the relative concentrations of cannabinol, cannabidiol and tetrahydrocannabinol depended on site and indoor/outdoor location at the site. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Effect of atmospheric organic complexation on iron-bearing dust solubility

    OpenAIRE

    Paris , R.; Desboeufs , K. V.

    2013-01-01

    International audience; Recent studies reported that the effect of organic complexation may be a potentially important process to be considered by models estimating atmospheric iron flux to the ocean. In this study, we investigated this process effect by a series of dissolution experiments on iron-bearing dust in the presence or the absence of various organic compounds (acetate, formate, oxalate, malonate, succinate, glutarate, glycolate, lactate, tartrate and humic acid as an analogue of hum...

  20. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres. Progress report, May 1, 1993--January 31, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Hopke, P.K.

    1993-01-01

    Progress is reported on the chemical and physical behavior of the {sup 218}Po atom immediately following its formation by the alpha decay of radon. Two areas of radon progeny behavior are being pursued; laboratory studies under controlled conditions to better understand the fundamental physical and chemical processes that affect the progeny`s atmospheric behavior and studies in actual indoor environments to develop a better assessment of the exposure of the occupants of that space to the size and concentration of the indoor radioactive aerosol. The specific tasks addressed were to determine the formation rates of {center_dot}OH radicals formed by the radiolysis of air following radon decay, to examine the formation of particles by the radiolytic oxidation of substances like SO{sub 2}, ethylene, and H{sub 2}S to lower vapor pressure compounds and determine the role of gas phase additives such as H{sub 2}O and NH{sub 3} in determining the particle size, to measure the rate of ion-induced nucleation using a thermal diffusion cloud chamber, and to measure the neutralization rate of {sup 218}PoO{sub x}{sup +} in O{sub 2} at low radon concentrations. Initial measurements were conducted of the activity size distributions in actual homes with occupants present so that the variability of the indoor activity size distributions can be assessed with respect to indoor aerosol sources and general lifestyle variations of the occupants. A prospective study of the utility of measurement of deposited {sup 210}Pb embedded in glass surfaces as a measure of the long-term, integrated exposure of the population to radon are described. Methodology was developed to determine the hygroscopicity of the indoor aerosol so that the changes in deposition efficiency of the radioactive indoor aerosol with hygroscopic growth in the respiratory tract can be assessed.

  1. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres. Progress report, July 1, 1991--June 30, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Hopke, P.K.

    1992-07-01

    This report covers the second year of the 28 month grant current grant to Clarkson University to study the chemical and physical behavior of the polonium 218 atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and it dose to the cells in the respiratory tract are to be fully assessed. Two areas of radon progeny behavior are being pursued; laboratory studies under controlled conditions to better understand the fundamental physical and chemical process that affect the progeny`s atmospheric behavior and studies in actual indoor environments to develop a better assessment of the exposure of the occupants of that space to the size and concentration of the indoor radioactive aerosol. This report describes the progress toward achieving these objectives.

  2. A contribution to the modelling of atmospheric corrosion of iron

    International Nuclear Information System (INIS)

    Hoerle, S.; Mazaudier, F.

    2003-01-01

    With the aim of predicting the long term atmospheric corrosion behaviour of iron, the characteristics of the rust layer formed during this process and the mechanisms occurring inside the rust layer during a wet-dry cycle are considered. A first step in modelling the behaviour is proposed, based on the description of the cathodic reactions associated with iron oxidation: reduction of a part of the rust layer (lepidocrocite) and reduction of dissolved oxygen on the rust layer. The modelling, by including some composition and morphological data of the rust layer as parameters, is able to account for the metal damage after one Wet-Dry cycle. (authors)

  3. Hourly indoor radon measurements in a research house.

    Science.gov (United States)

    Sesana, Lucia; Begnini, Stefania

    2004-01-01

    This paper reports and discusses the behaviour of radon concentration with time in an uninhabited dwelling. The relationship between variations in radon concentrations and indoor-outdoor temperatures and wind intensity has also been discussed. Radon concentration was measured hourly in a house located at a height of 800 m in the Lombard Prealps, at the top of the Valassina valley. The wind velocity and indoor-outdoor temperatures were measured by means of a meteorological station located on the terrace of the house. The data were analysed using the LBL model for indoor-outdoor air exchange and the models for the indoor accumulation of radon due to exhalation from building materials and pressure-driven infiltrations located underground. The role of wind and indoor-outdoor temperatures were analysed. The agreement of measurements with modelling clearly demonstrates the importance of the different sources of indoor radon. As the investigation was conducted in an uninhabited house, the measurements were not affected by the behaviour of people, e.g. opening and closing of windows. Measurements of the outdoor atmospheric concentrations of (222)Rn provide an index of the atmospheric stability, the formation of thermal inversions and convective turbulence.

  4. Hourly indoor radon measurements in a research house

    International Nuclear Information System (INIS)

    Sesana, L.; Begnini, S.

    2004-01-01

    This paper reports and discusses the behaviour of radon concentration with time in an uninhabited dwelling. The relationship between variations in radon concentrations and indoor-outdoor temperatures and wind intensity has also been discussed. Radon concentration was measured hourly in a house located at a height of 800 m in the Lombard Pre-alps, at the top of the Valassina valley. The wind velocity and indoor-outdoor temperatures were measured by means of a meteorological station located on the terrace of the house. The data were analysed using the LBL model for indoor-outdoor air exchange and the models for the indoor accumulation of radon due to exhalation from building materials and pressure-driven infiltrations located underground. The role of wind and indoor-outdoor temperatures were analysed. The agreement of measurements with modelling clearly demonstrates the importance of the different sources of indoor radon. As the investigation was conducted in an uninhabited house, the measurements were not affected by the behaviour of people, e.g. opening and closing of windows. Measurements of the outdoor atmospheric concentrations of 222 Rn provide an index of the atmospheric stability, the formation of thermal inversions and convective turbulence. (authors)

  5. Atomistic modeling of carbon Cottrell atmospheres in bcc iron

    Science.gov (United States)

    Veiga, R. G. A.; Perez, M.; Becquart, C. S.; Domain, C.

    2013-01-01

    Atomistic simulations with an EAM interatomic potential were used to evaluate carbon-dislocation binding energies in bcc iron. These binding energies were then used to calculate the occupation probability of interstitial sites in the vicinity of an edge and a screw dislocation. The saturation concentration due to carbon-carbon interactions was also estimated by atomistic simulations in the dislocation core and taken as an upper limit for carbon concentration in a Cottrell atmosphere. We obtained a maximum concentration of 10 ± 1 at.% C at T = 0 K within a radius of 1 nm from the dislocation lines. The spatial carbon distributions around the line defects revealed that the Cottrell atmosphere associated with an edge dislocation is denser than that around a screw dislocation, in contrast with the predictions of the classical model of Cochardt and colleagues. Moreover, the present Cottrell atmosphere model is in reasonable quantitative accord with the three-dimensional atom probe data available in the literature.

  6. Indoor and outdoor poly- and perfluoroalkyl substances (PFASs) in Korea determined by passive air sampler

    International Nuclear Information System (INIS)

    Kim, Seung-Kyu; Shoeib, Mahiba; Kim, Kyeong-Soo; Park, Jong-Eun

    2012-01-01

    Despite concerns to their increasing contribution to ecological and human exposure, the atmospheric levels of poly- and perfluoroalkyl substances (PFASs) have been determined mainly in Europe and North America. This study presents the indoor and outdoor air concentrations of volatile PFASs [fluorotelomer alcohols (FTOHs), and perfluoroalkyl sulfonamides/sulfonamidoethanols/sulfonamide ethyl acetate (FOSAs/FOSEs/FOSEA)] for the first time in Korean cities. In contrast to the good agreement observed for indoor FTOHs levels in Korea and Europea/North America, FOSAs/FOSEs levels were 10–100-fold lower in Korean indoor air, representing a cultural difference of indoor source. Korean outdoor air contained higher PFAS levels than indoor air, and additionally showed different PFAS composition profile from indoor air. Thus, indoor air would not likely be a main contributor to atmospheric PFAS contamination in Korea, in contrast to western countries. Inhalation exposure of volatile PFASs was estimated to be a minor contributor to PFOA and PFOS exposure in Korea. - Highlights: ► Volatile PFASs were measured in indoor and outdoor airs of Korea, for the first time. ► Cultural difference in indoor source was observed for Korea v.s. western countries. ► Furthermore, PFASs concentrations were higher in indoor air than outdoor air. ► Indoor air was not a major contributor to atmospheric PFASs contamination in Korea. ► Release from industrial activities was considered a possible source. - Korean outdoor air showed not only different PFAS composition profile but higher PFAS levels than indoor airs, indicating indoor air would not be a main source to Korean atmospheric PFASs.

  7. The impact on atmospheric CO2 of iron fertilization induced changes in the ocean's biological pump

    Science.gov (United States)

    Jin, X.; Gruber, N.; Frenzel, H.; Doney, S. C.; McWilliams, J. C.

    2008-03-01

    Using numerical simulations, we quantify the impact of changes in the ocean's biological pump on the air-sea balance of CO2 by fertilizing a small surface patch in the high-nutrient, low-chlorophyll region of the eastern tropical Pacific with iron. Decade-long fertilization experiments are conducted in a basin-scale, eddy-permitting coupled physical/biogeochemical/ecological model. In contrast to previous studies, we find that most of the dissolved inorganic carbon (DIC) removed from the euphotic zone by the enhanced biological export is replaced by uptake of CO2 from the atmosphere. Atmospheric uptake efficiencies, the ratio of the perturbation in air-sea CO2 flux to the perturbation in export flux across 100 m, integrated over 10 years, are 0.75 to 0.93 in our patch size-scale experiments. The atmospheric uptake efficiency is insensitive to the duration of the experiment. The primary factor controlling the atmospheric uptake efficiency is the vertical distribution of the enhanced biological production and export. Iron fertilization at the surface tends to induce production anomalies primarily near the surface, leading to high efficiencies. In contrast, mechanisms that induce deep production anomalies (e.g. altered light availability) tend to have a low uptake efficiency, since most of the removed DIC is replaced by lateral and vertical transport and mixing. Despite high atmospheric uptake efficiencies, patch-scale iron fertilization of the ocean's biological pump tends to remove little CO2 from the atmosphere over the decadal timescale considered here.

  8. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Hopke, P.K.

    1992-07-01

    This report describes studies on the chemical and physical behavior of the [sup 218]Po atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity in the sub-10 nm size range result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and its dose to the cells in the respiratory tract are to be fully assessed. The specific tasks of the controlled laboratory studies are to determine the formation rates of [center dot]OH radicals formed by the radiolysis of air following radon decay, to examine the formation of particles by the radiolytic oxidation of substances like SO[sub 2] ethylene, and H[sub 2]S to lower vapor pressure compounds and determine the role of gas phase additives such as H[sub 2]O and NH[sub 3] in determining the particle size, to measure the rate of ion-induced nucleation using a thermal diffusion cloud chamber, and to measure the neutralization rate of [sup 218]Po[sub x][sup +] in O[sub 2] at low radon concentrations. Tasks of the exposure studies in occupied indoor spaces are to initiate measurements of the activity size distributions in actual homes with occupants present so that the variability of the indoor activity size distributions can be assessed with respect to indoor aerosol sources and general lifestyle variations of the occupants, to initiate a prospective study of the utility of measurement of deposited [sup 210]Pb embedded in glass surfaces as a measure of the long-term, integrated exposure of the population to radon, and to develop the methodology to determine the hygroscopicity of the indoor aerosol so that the changes in deposition efficiency of the radioactive indoor aerosol with hygroscopic growth in the respiratory tract can be assessed.

  9. Behaviors of radon in indoor environment

    International Nuclear Information System (INIS)

    Mochizuki, Sadamu; Shimo, Michikuni.

    1987-01-01

    The source of radon ( 222 Rn) in the atmosphere is radioactive nuclide, uranium ( 238 U), which exists fairly common throughout the earth's crust. Radium ( 226 Ra) descended from uranium produce radon ( 222 Rn) of noble gas by decay. After formation in the ground, radon diffuses into the atmosphere. Without exception radon decay products are heavy metals which soon become attached to natural aerosols. Therefore, radon and its daughters (decay products) appear also in indoor environment, and generally, their concentration levels become higher than that of outdoor air due to build-up effects in the closed indoor environments. With the progress of the study on the influence of radon and its daughers on human health, it has become clear that they act effectively as an exciting cause of lung cancer. So, the study on the risk evaluation of them in room air has become to be very important. Concequently, the behaviors of radon and its daughters in indoor environment, first of all, should be studied in detail for the accurate estimation of the risk caused by them. In this special edition, fundamental characteristics of radon and its daughters, some measuring methods, theoretical considerations and some observational evidences obtained from various circumstances of indoor environment are described inorder to grasp and understand the behaviors of radon and its daughters in the indoor environment. (author)

  10. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres. Final project report

    International Nuclear Information System (INIS)

    Hopke, P.K.

    1996-09-01

    This report completes Clarkson University's study of the chemical and physical behavior of the 218 Po atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity in the sub-10 nm size range result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and it dose to the cells in the respiratory tract are to be fully assessed. In order to pursue this general goal, two areas of radon progeny behavior are being pursued; laboratory studies under controlled conditions to better understand the fundamental physical and chemical processes that affect the progeny's atmospheric behavior and studies in actual indoor environments to develop a better assessment of the exposure of the occupants of that space to the size and concentration of the indoor radioactive aerosol. Thus, two sets of specific goals have been established for this project. The specific tasks of the controlled laboratory studies are (1) Determine the formation rates of circ OH radicals formed by the radiolysis of air following radon decay; (2) Examine the formation of particles by the radiolytic oxidation of substances like SO 2 , ethylene, and H 2 S to lower vapor pressure compounds and determine the role of gas phase additives such as H 2 O and NH 3 in determining the particle size; (3) Measure the rate of ion-induced nucleation using a thermal diffusion cloud chamber, and (4) Measure the neutralization rate of 218 PoO x + in O 2 at low radon concentrations

  11. The impact on atmospheric CO2 of iron fertilization induced changes in the ocean's biological pump

    Directory of Open Access Journals (Sweden)

    J. C. McWilliams

    2008-03-01

    Full Text Available Using numerical simulations, we quantify the impact of changes in the ocean's biological pump on the air-sea balance of CO2 by fertilizing a small surface patch in the high-nutrient, low-chlorophyll region of the eastern tropical Pacific with iron. Decade-long fertilization experiments are conducted in a basin-scale, eddy-permitting coupled physical/biogeochemical/ecological model. In contrast to previous studies, we find that most of the dissolved inorganic carbon (DIC removed from the euphotic zone by the enhanced biological export is replaced by uptake of CO2 from the atmosphere. Atmospheric uptake efficiencies, the ratio of the perturbation in air-sea CO2 flux to the perturbation in export flux across 100 m, integrated over 10 years, are 0.75 to 0.93 in our patch size-scale experiments. The atmospheric uptake efficiency is insensitive to the duration of the experiment. The primary factor controlling the atmospheric uptake efficiency is the vertical distribution of the enhanced biological production and export. Iron fertilization at the surface tends to induce production anomalies primarily near the surface, leading to high efficiencies. In contrast, mechanisms that induce deep production anomalies (e.g. altered light availability tend to have a low uptake efficiency, since most of the removed DIC is replaced by lateral and vertical transport and mixing. Despite high atmospheric uptake efficiencies, patch-scale iron fertilization of the ocean's biological pump tends to remove little CO2 from the atmosphere over the decadal timescale considered here.

  12. Indoor and outdoor urban atmospheric CO2: Stable carbon isotope constraints on mixing and mass balance

    International Nuclear Information System (INIS)

    Yanes, Yurena; Yapp, Crayton J.

    2010-01-01

    suggests that the intercept of a mixing line defined by two data points (CO 2 input from the local ventilation system and CO 2 in the ambient air of the room) could be a reasonable estimate of the average δ 13 C value of the CO 2 exhaled by the human occupants. Thus, such indoor spaces appear to constitute effective 'sample vessels' for collection of CO 2 that can be used to determine the average proportions of C 3 and C 4 -derived C in the diets of the occupants. For the various groups occupying the rooms sampled in this study, C 4 -derived C appears to have constituted ∼40% of the average diet. The average concentration of outdoor Dallas atmospheric CO 2 was ∼17 ppm higher than the average of CO 2 concentrations measured on the same campus 10 a ago. In addition, Dallas outdoor CO 2 concentrations at both times were higher than the contemporaneous global atmospheric CO 2 concentrations. This observation, plus the fact that the increase of ∼17 ppm in the average concentration of Dallas outdoor CO 2 was comparable to the global increase of ∼18 ppm over the same 10-a interval, is consistent with a significant role for urban CO 2 'factories' in the global atmospheric CO 2 budget.

  13. Atmospheric Processing of Volcanic Glass: Effects on Iron Solubility and Redox Speciation.

    Science.gov (United States)

    Maters, Elena C; Delmelle, Pierre; Bonneville, Steeve

    2016-05-17

    Volcanic ash from explosive eruptions can provide iron (Fe) to oceanic regions where this micronutrient limits primary production. Controls on the soluble Fe fraction in ash remain poorly understood but Fe solubility is likely influenced during atmospheric transport by condensation-evaporation cycles which induce large pH fluctuations. Using glass powder as surrogate for ash, we experimentally simulate its atmospheric processing via cycles of pH 2 and 5 exposure. Glass fractional Fe solubility (maximum 0.4%) is governed by the pH 2 exposure duration rather than by the pH fluctuations, however; pH 5 exposure induces precipitation of Fe-bearing nanoparticles which (re)dissolve at pH 2. Glass leaching/dissolution release Fe(II) and Fe(III) which are differentially affected by changes in pH; the average dissolved Fe(II)/Fetot ratio is ∼0.09 at pH 2 versus ∼0.18 at pH 5. Iron release at pH 2 from glass with a relatively high bulk Fe(II)/Fetot ratio (0.5), limited aqueous Fe(II) oxidation at pH 5, and possibly glass-mediated aqueous Fe(III) reduction may render atmospherically processed ash a significant source of Fe(II) for phytoplankton. By providing new insight into the form(s) of Fe associated with ash as wet aerosol versus cloud droplet, we improve knowledge of atmospheric controls on volcanogenic Fe delivery to the ocean.

  14. Regional contributions of ocean iron fertilization to atmospheric CO2 changes during the last glacial termination

    Science.gov (United States)

    Opazo, N. E.; Lambert, F.

    2017-12-01

    Mineral dust aerosols affect climate directly by changing the radiative balance of the Earth, and indirectly by acting as cloud condensation nuclei and by affecting biogeochemical cycles. The impact on marine biogeochemical cycles is primarily through the supply of micronutrients such as iron to nutrient-limited regions of the oceans. Iron fertilization of High Nutrient Low Chlorophyll (HNLC) regions of the oceans is thought to have significantly affected the carbon cycle on glacial-interglacial scales and contributed about one fourth of the 80-100 ppm lowering of glacial atmospheric CO2 concentrations.In this study, we quantify the effect of global dust fluxes on atmospheric CO2 using the cGENIE model, an Earth System Model of Intermediate Complexity with emphasis on the carbon cycle. Global Holocene and Last Glacial Maximum (LGM) dust flux fields were obtained from both dust model simulations and reconstructions based on observational data. The analysis was performed in two stages. In the first instance, we produced 8 global intermediate dust flux fields between Holocene and LGM and simulated the atmospheric CO2 drawdown due to these 10 dust levels. In the second stage, we only changed dust flux levels in specific HNLC regions to isolate the effect of these ocean basins. We thus quantify the contribution of the South Atlantic, the South Pacific, the North Pacific, and the Central Pacific HNLC regions to the total atmospheric CO2 difference due to iron fertilization of the Earth's oceans.

  15. The impact of particle size, relative humidity, and sulfur dioxide on iron solubility in simulated atmospheric marine aerosols.

    Science.gov (United States)

    Cartledge, Benton T; Marcotte, Aurelie R; Herckes, Pierre; Anbar, Ariel D; Majestic, Brian J

    2015-06-16

    Iron is a limiting nutrient in about half of the world's oceans, and its most significant source is atmospheric deposition. To understand the pathways of iron solubilization during atmospheric transport, we exposed size segregated simulated marine aerosols to 5 ppm sulfur dioxide at arid (23 ± 1% relative humidity, RH) and marine (98 ± 1% RH) conditions. Relative iron solubility increased as the particle size decreased for goethite and hematite, while for magnetite, the relative solubility was similar for all of the fine size fractions (2.5-0.25 μm) investigated but higher than the coarse size fraction (10-2.5 μm). Goethite and hematite showed increased solubility at arid RH, but no difference (p > 0.05) was observed between the two humidity levels for magnetite. There was no correlation between iron solubility and exposure to SO2 in any mineral for any size fraction. X-ray absorption near edge structure (XANES) measurements showed no change in iron speciation [Fe(II) and Fe(III)] in any minerals following SO2 exposure. SEM-EDS measurements of SO2-exposed goethite revealed small amounts of sulfur uptake on the samples; however, the incorporated sulfur did not affect iron solubility. Our results show that although sulfur is incorporated into particles via gas-phase processes, changes in iron solubility also depend on other species in the aerosol.

  16. Effectiveness of using pure copper and silver coupon corrosivity monitoring (CCM) metal strips to measure the severity levels of air pollutants in indoor and outdoor atmospheres

    CSIR Research Space (South Africa)

    Foax, LJ

    2008-10-01

    Full Text Available Severity levels of air pollutants rich in oxides, chlorides and sulphides were successfully measured in indoor and outdoor atmospheres using pure copper and silver coupon corrosivity monitoring (CCM) metal strips when the maximum exposure periods...

  17. Red Dawn: Characterizing Iron Oxide Minerals in Atmospheric Dust

    Science.gov (United States)

    Yauk, K.; Ottenfeld, C. F.; Reynolds, R. L.; Goldstein, H.; Cattle, S.; Berquo, T. S.; Moskowitz, B. M.

    2012-12-01

    Atmospheric dust is comprised of many components including small amounts of iron oxide minerals. Although the iron oxides make up a small weight percent of the bulk dust, they are important because of their roles in ocean fertilization, controls on climate, and as a potential health hazard to humans. Here we report on the iron oxide mineralogy in dust from a large dust storm, dubbed Red Dawn, which engulfed eastern Australia along a 3000 km front on 23 September 2009. Red Dawn originated from the lower Lake Eyre Basin of South Australia, western New South Wales (NSW) and southwestern Queensland and was the worst dust storm to have hit the city of Sydney in more than 60 years. Dust samples were collected from various locations across eastern Australia (Lake Cowal, Orange, Hornsby, Sydney) following the Red Dawn event. Our dust collection provides a good opportunity to study the physical and mineralogical properties of iron oxides from Red Dawn using a combination of reflectance spectroscopy, Mössbauer spectroscopy (MB), and magnetic measurements. Magnetization measurements from 20-400 K reveal that magnetite/maghemite, hematite and goethite are present in all samples with magnetite occurring in trace amounts (effects (d< 100 nm). Finally, we compared reflectance with a magnetic parameter (hard isothermal remanent magnetization, HIRM) for ferric oxide abundance to assess the degree to which ferric oxide in these samples might absorb solar radiation. In samples for which both parameters were obtained, HIRM and average reflectance over the visible wavelengths are correlated as a group (r2=0.24). These results indicate that the ferric oxide minerals in Red Dawn dust absorb solar radiation. Much of this ferric oxide occurs likely as grain coatings of nanohematite and nanogoethite, thereby providing high surface area to enhance absorption of solar radiation.

  18. Indoor radon concentration and outdoor/indoor pressure difference correlation

    International Nuclear Information System (INIS)

    Cechak, T.; Fronka, A.; Moucka, L.

    2004-01-01

    In the current approach to the radon issue, the radon risk for people living in a building is estimated based on the average indoor radon concentration. Short-term measurements as usually applied fail to reflect the wide range of radon variations arising from ventilation, radon supply and, in particular, human activities in the building. For this reason, efforts are made to find a new approach to the assessment of the quality of a building as a radon barrier, independent of the weather conditions and residential habits. A simple model of radon volume activity entering the building at a constant rate and simultaneously ventilated at a constant rate is applicable to this task. The rate of radon ingress can be regarded as a parameter making it possible to quantify the leakage of structures provided the barrier against the radon in a soil gas. The ventilation rate, on the other hand, characterizes the leakage of the whole building envelope at a given outdoor/indoor pressure difference. A unique measuring technique called the blower door exists whereby a defined pressure difference between the indoor and outdoor atmosphere can be established. Under such conditions both the ventilation rate and the rate of radon ingress can be measured and expressed as a function of the pressure difference. An analysis of the model of a room with a constant ventilation and constant radon supply is presented and the relationship between radon supply and ventilation rate can be assumed. Some experimental results show how the model can be utilized. The real indoor-outdoor air pressure differences, the indoor-soil air pressure differences, and some effects of different ventilation regimes are given. Other experiments, which have been done by using the blower door method, illustrate the possible effects and some restrictions for a routine application are discussed

  19. 57Fe Moessbauer spectroscopic study on surface products of thin iron plates exposed to ambient atmosphere as a means of environmental monitoring

    International Nuclear Information System (INIS)

    Matsuo, Motoyuki; Kobayashi, Takaaki

    1993-01-01

    Conversion electron and transmission Moessbauer spectroscopy were applied to the analysis of thin iron plates exposed to the ambient atmosphere. The degree of corrosion of the iron plates was classified into three categories according to the kind and thickness of rust evaluated by Moessbauer spectra. The severe corrosion took place in seaside and roadside areas. The medium corrosion was observed in urban areas, and the weak corrosion occurred in suburban and mountainous areas. This fact implies that the surface products of iron plates can successfully reflect the ambient atmosphere to which the plates were exposed. (orig.)

  20. Indoor Air Pollution by Methylsiloxane in Household and Automobile Settings.

    Directory of Open Access Journals (Sweden)

    Fanyong Meng

    Full Text Available This study examines characteristics of atmospheric methylsiloxane pollution in indoor settings where interior renovation/redecoration is being undertaken, in addition to ordinary family homes and inside family cars. Concentrations of atmospheric methylsiloxane in these locations were approximately one order of magnitude higher than that in outdoor areas. The average indoor concentration of methylsiloxane where renovation was being undertaken was 9.4 μg/m3, which is slightly higher than that in an ordinary family home (7.88 μg/m3, while samples from family cars showed lower concentration (3.10 μg/m3. The indoor atmospheric concentration during renovation/redecoration work was significantly positively correlated with the duration of the work. The structure of atmospheric methylsiloxane pollution is basically the same in these three venues. The concentration of annulus siloxane was much higher than that of linear compounds (85% of the total methylsiloxane concentrations. Household dust in average family homes showed total methylsiloxane concentration of 9.5 μg/m3 (average; the structure mainly consisted of linear siloxane (approximately 98% of total concentration, thereby differing from that of atmospheric methylsiloxane pollution. The comparatively high concentration of methylsiloxane in these three venues indicates that interior renovation and decoration work, and even travelling in cars, can involve exposure to more serious siloxane contamination during everyday activities.

  1. Atmospheric delivery of anthropogenic bioavailable iron from mineral dust to the ocean

    OpenAIRE

    伊藤, 彰記; 時, 宗波; ITO, Akinori; SHI, Zongbo

    2015-01-01

    Atmospheric deposition of anthropogenic soluble iron (Fe) to the ocean has been suggested to modulate primary ocean productivity and thus indirectly affect the climate. A key process contributing to anthropogenic sources of soluble Fe is associated with air pollution, which acidifies Fe-containing mineral aerosols during their transport and leads to Fe transformation from insoluble to soluble forms. However, there is large uncertainty in our estimate of this anthropogenic soluble Fe. Here, we...

  2. Kinetics of atmospheric corrosion of mild steel, zinc, galvanized iron and aluminium at 10 exposure stations in India

    International Nuclear Information System (INIS)

    Natesan, M.; Venkatachari, G.; Palaniswamy, N.

    2006-01-01

    As a part of updating Corrosion Map of India project, atmospheric corrosion behaviour of commercially available engineering materials such as mild steel, galvanized iron, zinc and aluminium metals was studied in marine, industrial, urban, and rural environments by weight loss method at 10 exposure stations in India over a period of 5 years. The results of these studies demonstrated that galvanized iron, zinc and aluminium metals were several times more durable than mild steel. Compared to galvanized iron and zinc, aluminium provided superior protection in industrial and marine environment except at Mormugao Port Trust (MPT). It also offered much better resistance to corrosion in rural environments. At certain places, galvanized iron proved to be more durable than aluminium. The results obeyed well with the empirical kinetics equation of the form C = Kt n , where K and C are the corrosion losses in μm after 1 and 't' years of the exposure, respectively, and 'n' is a constant. Based on 'n' values, the corrosion mechanisms of these metals are predicted. The corrosion products formed on the metal samples in Chennai marine atmosphere were identified by X-ray diffraction analysis

  3. Evolution of the gas atmosphere during filing the sand moulds with iron alloys

    Directory of Open Access Journals (Sweden)

    J. Mocek

    2009-10-01

    Full Text Available Evolution of atmosphere of the mould cavity when pouring the cast iron has been analyzed. It was find that in dry sand mold the cavity is filled by air throughout the casting time. In green sand the air is removed by the water vapor the hydrogen or carbon oxides formed in contact with the liquid metal. The theoretical results have been confirmed experimentally.

  4. Nanophase Iron Oxides as an Ultraviolet Sunscreen for Ancient Photosynthetic Microbes: A Possible Link Between Early Organisms, Banded-Iron Formations, and the Oxygenation of the Atmosphere

    Science.gov (United States)

    Bishop, Janice L.; Rothschild, Lynn J.; Rothschild, Lynn J.; Rogoff, Dana A.

    2006-01-01

    We propose that nanophase iron oxide-bearing materials provided important niches for ancient photosynthetic microbes on the early Earth that ultimately led to the oxygenation of the Earth s atmosphere and the formation of iron oxide deposits. Atmospheric oxygen and ozone attenuate UV radiation on the Earth today providing substantial protection for photosynthetic organisms. With ultraviolet radiation fluxes likely to have been even higher on the early Earth than today, accessing solar radiation was particularly risky for early organisms. Yet, we know that photosynthesis arose then and played a critical role in subsequent evolution. Of primary importance was protection at approx.250-290 nm, where peak nucleic acid (approx.260 nm) and protein (approx.280 nm) absorptions occur. Nanophase ferric oxide/oxyhydroxide minerals absorb, and thus block, the lethal UV radiation, while transmitting light through much of the visible and near-infrared regions of interest to photosynthesis (400 to 1100 nm). Further, they were available in early environments, and are synthesized by many organisms. Based on ferric oxide/oxyhydroxide spectral properties, likely geologic processes, and the results of experiments with the photosynthetic organisms, Euglena sp. and Chlumydomonus reinhardtii, we propose a scenario where photosynthesis, and ultimately the oxygenation of the atmosphere, depended on the protection of early microbes by nanophase ferric oxides/oxyhydroxides. The results of this study are also applicable to other potentially habitable iron-bearing planetary bodies because of the evolutionary pressure to utilize solar radiation when available as an energy source.

  5. Ultrasensitive and Fast Voltammetric Determination of Iron in Seawater by Atmospheric Oxygen Catalysis in 500 μL Samples.

    Science.gov (United States)

    Caprara, Salvatore; Laglera, Luis M; Monticelli, Damiano

    2015-06-16

    A new method based on adsorptive cathodic stripping voltammetry with catalytic enhancement for the determination of total dissolved iron in seawater is reported. It was demonstrated that iron detection at the ultratrace level (0.1 nM) may be achieved in small samples (500 μL) with high sensitivity, no need for purging, no added oxidant, and a limit of detection of 5 pM. The proposed method is based on the adsorption of the complex Fe/2,3-dihydroxynaphthalene (DHN) exploiting the catalytic effect of atmospheric oxygen. As opposite to the original method (Obata, H.; van den Berg, C. M. Anal. Chem. 2001, 73, 2522-2528), atmospheric oxygen dissolved in solution replaced bromate ions in the oxidation of the iron complex: removing bromate reduces the blank level and avoids the use of a carcinogenic species. Moreover, the new method is based on a recently introduced hardware that enables the determinations to be performed in 500 μL samples. The analyses were carried out on buffered samples (pH 8.15, HEPPS 0.01 M), 10 μM DHN and iron quantified by the standard addition method. The sensitivity is 49 nA nM(-1) min(-1) with 30 s deposition time and the LOD is equal to 5 pM. As a result, the whole procedure for the quantification of iron in one sample requires around 7.5 min. The new method was validated via analysis on two reference samples (SAFe S and SAFe D2) with low iron content collected in the North Pacific Ocean.

  6. Environmental radiation hazards around some iron mines and steel plants of Karnataka state

    International Nuclear Information System (INIS)

    Sannappa, J.

    2013-01-01

    The primordial radionuclides ( 226 Ra, 232 Th and 40 K) are present in air, food, water, soils, rocks, mineral ores and building materials, are the sources of natural radiation. The sun, stars, rocks, and even our own body emits natural radiation. We live in a sea of natural radioactivity. Work activities involved in naturally occurring radioactive materials (NORM) are potential sources of radiation exposure to workers and members of publics. Iron, Chromite, Uranium, Phosphate and other ores contains higher activity of radionuclides. The iron ore is widely distributed in Bellary, Chitradurga, Tumkur and Chickmagalore districts of Karnataka state. The mining creates a number of environmental problems, that is destructions of important fauna and flora in this affected areas and also this leads various diseases like asthma, leukemia intestine, kidney and liver damage and lung cancer. The environmental γ-radiation levels were measured in this study area using environmental radiation dosimetry. The activity of radionuclides present in the ore samples were estimated by using Hyper Pure Germanium Detector (HPGe). The radon concentration in groundwater and indoor and outdoor concentration were measured by Emanometry and SSNTD techniques. The higher gamma equivalent effective doses were observed at the industrial operation and where the large quantity of iron ore and fines were dumped at the mining sites. The absorbed gamma dose to the workers in study area is slightly higher than the global average. The present work highlights the influence of mining activity, mineral processing and industrial operations are enhanced the fine sized particles, and radon in indoor and outdoor atmosphere is the sources of external radiation dose to the workers and publics. (author)

  7. Atmospheric iron supply and enhanced vertical carbon flux in the NE subarctic Pacific: Is there a connection?

    Science.gov (United States)

    Boyd, P. W.; Wong, C. S.; Merrill, J.; Whitney, F.; Snow, J.; Harrison, P. J.; Gower, J.

    1998-09-01

    Recent studies have confirmed the relationship between iron supply and phytoplankton growth rates in all three high-nitrate low-chlorophyll (HNLC) oceanic provinces. However, there is little evidence, so far, of the role of iron in altering the efficiency of the biological pump via increased downward export of particulate organic carbon (POC). The NE subarctic Pacific is unique among HNLC regions in that long time series pelagic observations and deep-moored sediment trap records exist which may provide the best opportunity thus far to test aspects of the iron hypothesis. Episodic elevated levels of chlorophyll a (> 2.0 μg L-1) were observed 6 times between 1964 and 1976 at the former site of Ocean Station Papa (OSP). In addition, between 1984 and 1990 on at least three occasions, concurrent pulses of POC and biogenic silica were recorded in deep-moored traps at OSP. Possible explanations for these events, such as lateral advection of more productive waters, iron-mediated blooms, or grazing by salp swarms are discussed and tested using an existing downward POC flux model. Owing to the episodic nature of such events, no available data are sufficiently comprehensive to unequivocally rule out any of these explanations. Nevertheless, from the data available, the occurrence of pelagic or deep water pulses, approximately once every 3 years, are most consistent with iron-mediated diatom blooms, and of the sinking of POC and biogenic silica (from such a bloom) to depth, respectively. A comparison of the timing of these iron-mediated pulses with that of the transport probabilities of atmospheric dust supply from Asia and Alaska provides an opportunity to assess the likelihood of a coupling between the atmosphere and the ocean.

  8. Daily variation of the radon concentration indoors and outdoors and the influence of meteorological parameters

    International Nuclear Information System (INIS)

    Porstendoerfer, J.; Butterweck, G.; Reineking, A.

    1994-01-01

    Series of continuous radon measurements in the open atmosphere and in a dwelling, including the parallel measurement of meteorological parameters, were performed over a period of several weeks. The radon concentration in indoor and outdoor air depends on meteorological conditions. In the open atmosphere the radon concentration varies between 1 and 100 Bq m -3 , depending on weather conditions and time of day. During time periods of low turbulent air exchange (high pressure weather with clear night sky), especially in the night and early morning hours (night inversion layer), the diurnal variation of the radon concentration showed a pronounced maximum. Cloudy and windy weather conditions yield a small diurnal variation of the radon concentration. Indoors, the average level and the diurnal variation of the indoor radon concentration is also influenced by meteorological conditions. The measurements are consistent with a dependence of indoor radon concentrations on indoor-outdoor pressure differences. 11 refs., 4 figs

  9. Atomic-scale investigation of point defects and hydrogen-solute atmospheres on the edge dislocation mobility in alpha iron

    Energy Technology Data Exchange (ETDEWEB)

    Bhatia, M. A.; Solanki, K. N., E-mail: kiran.solanki@asu.edu [School for Engineering of Matter, Transport, and Energy, Arizona State University, Tempe, Arizona 85287 (United States); Groh, S. [Institute of Mechanics and Fluid Dynamics, TU Bergakademie Freiberg, Freiberg 09556 (Germany)

    2014-08-14

    In this study, we present atomistic mechanisms of 1/2 [111](11{sup ¯}0) edge dislocation interactions with point defects (hydrogen and vacancies) and hydrogen solute atmospheres in body centered cubic (bcc) iron. In metals such as iron, increases in hydrogen concentration can increase dislocation mobility and/or cleavage-type decohesion. Here, we first investigate the dislocation mobility in the presence of various point defects, i.e., change in the frictional stress as the edge dislocation interacts with (a) vacancy, (b) substitutional hydrogen, (c) one substitutional and one interstitial hydrogen, (d) interstitial hydrogen, (e) vacancy and interstitial hydrogen, and (f) two interstitial hydrogen. Second, we examine the role of a hydrogen-solute atmosphere on the rate of local dislocation velocity. The edge dislocation simulation with a vacancy in the compression side of the dislocation and an interstitial hydrogen atom at the tension side exhibit the strongest mechanical response, suggesting a higher potential barrier and hence, the higher frictional stress (i.e., ∼83% higher than the pure iron Peierls stress). In the case of a dislocation interacting with a vacancy on the compressive side, the vacancy binds with the edge dislocation, resulting in an increase in the friction stress of about 28% when compared with the Peierls stress of an edge dislocation in pure iron. Furthermore, as the applied strain increases, the vacancy migrates through a dislocation transportation mechanism by attaining a velocity of the same order as the dislocation velocity. For the case of the edge dislocation interacting with interstitial hydrogen on the tension side, the hydrogen atom jumps through one layer perpendicular to the glide plane during the pinning-unpinning process. Finally, our simulation of dislocation interactions with hydrogen show first an increase in the local dislocation velocity followed by a pinning of the dislocation core in the atmosphere, resulting in

  10. A study on seasonal variations of indoor gamma dose in Bangladesh

    International Nuclear Information System (INIS)

    Miah, M. Idrish

    2005-01-01

    Monthly variation of gamma dose rate measured in indoor air of buildings of Bangladesh was found to vary cosinusoidally through a period of 1 year. Significant seasonal variations were observed. Maximum dose rate, however, was observed in January and a minimum in July. Dose rate in January was 32% higher than the annual average, whereas dose rate in July was 50% lower. Seasonally varied ventilation and air exchange rates of the houses might play an important role in the observed variation. The average reduction with respect to winter dose was 59% in summer. Because of lower ventilation and air exchange rates between indoor and outdoor atmosphere, it is expected that the indoor dose rate would be higher in basements than that of upper floors. Monthly dose rate was also found to be influenced by the meteorological conditions. Correlations between dose rate and temperature (r 2 =0.85), rainfall (r=-0.83) and atmospheric pressure (r=0.92) were obtained, but no significant correlation (r=-0.45) was seen between dose rate and humidity. The results show that the seasonal variations of indoor dose rates should be taken into account to estimate annual effective dose equivalent. (author)

  11. Global Modeling Study of the Bioavailable Atmospheric Iron Supply to the Global Ocean

    Science.gov (United States)

    Myriokefalitakis, S.; Krol, M. C.; van Noije, T.; Le Sager, P.

    2017-12-01

    Atmospheric deposition of trace constituents acts as a nutrient source to the open ocean and affect marine ecosystem. Dust is known as a major source of nutrients to the global ocean, but only a fraction of these nutrients is released in a bioavailable form that can be assimilated by the marine biota. Iron (Fe) is a key micronutrient that significantly modulates gross primary production in the High-Nutrient-Low-Chlorophyll (HNLC) oceans, where macronutrients like nitrate are abundant, but primary production is limited by Fe scarcity. The global atmospheric Fe cycle is here parameterized in the state-of-the-art global Earth System Model EC-Earth. The model takes into account the primary emissions of both insoluble and soluble Fe forms, associated with mineral dust and combustion aerosols. The impact of atmospheric acidity and organic ligands on mineral dissolution processes, is parameterized based on updated experimental and theoretical findings. Model results are also evaluated against available observations. Overall, the link between the labile Fe atmospheric deposition and atmospheric composition changes is here demonstrated and quantified. This work has been financed by the Marie-Curie H2020-MSCA-IF-2015 grant (ID 705652) ODEON (Online DEposition over OceaNs; modeling the effect of air pollution on ocean bio-geochemistry in an Earth System Model).

  12. Location Fingerprint Extraction for Magnetic Field Magnitude Based Indoor Positioning

    Directory of Open Access Journals (Sweden)

    Wenhua Shao

    2016-01-01

    Full Text Available Smartphone based indoor positioning has greatly helped people in finding their positions in complex and unfamiliar buildings. One popular positioning method is by utilizing indoor magnetic field, because this feature is stable and infrastructure-free. In this method, the magnetometer embedded on the smartphone measures indoor magnetic field and queries its position. However, the environments of the magnetometer are rather harsh. This harshness mainly consists of coarse-grained hard/soft-iron calibrations and sensor electronic noise. The two kinds of interferences decrease the position distinguishability of the magnetic field. Therefore, it is important to extract location features from magnetic fields to reduce these interferences. This paper analyzes the main interference sources of the magnetometer embedded on the smartphone. In addition, we present a feature distinguishability measurement technique to evaluate the performance of different feature extraction methods. Experiments revealed that selected fingerprints will improve position distinguishability.

  13. Conference particulate matter and indoor environment, I.N.E.R.I.S.; Particulate matter and indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    Comprehensive characterisation of indoor and outdoor air as well as pollution emission sources Integrated health and environmental risk assessment Scientific and technical basis for airborne pollution management and control Fine and coarse particles. The sources of indoor air pollution are originate separately, are transported separately, are removed from atmosphere by different mechanisms, have different optical properties, have different chemical properties, require different control techniques. for the health effects due to particles, they decrease the lung function, increase respiratory symptoms, increase chronic obstructive pulmonary diseases, increased cardiovascular disease, increased mortality. The different sources contributing to the highest concentrations are: concentrations: tobacco smoking, cooking, vacuuming, dusting and sweeping, heaters, stoves, fireplaces and some other non identified sources. In the future we want more focus on fine and ultra fine particles, investigate source apportionment of particles, better understanding and quantification of exposure, to implement guidelines for particle concentration in indoor air and find better cleaning technologies. (N.C.)

  14. Indoor air quality in the Greater Beirut area: a characterization and modeling assessment

    International Nuclear Information System (INIS)

    El-Fadel, Mutasem; El-Hougeiri, Nisrine; Oulabi, Mawiya

    2003-01-01

    This report presents the assessment of IAQ at various environments selected from different geographic categories from the Greater Beirut area (GBA) in Lebanon. For this purpose, background information about indoor air quality was reviewed, existing conditions were characterized, an air-sampling program was implemented and mathematical modeling was conducted. Twenty-eight indoor buildings were selected from various geographic categories representing different environments (commercial and residential...). Indoor and outdoor air samples were collected and analyzed using carbon monoxide (CO), particulate matter (TSP), nitrogen dioxide (NO 2 ) and total volatile organic compounds (TVOC) as indicators of indoor air pollution (IAP).Samples were further analyzed using the energy dispersive x-ray fluorescence technique (EDXRF) for the presence of major priority metals including iron (Fe), calcium (Ca), zinc (Zn), lead (Pb), manganese (Mn), copper (Cu) and bromine (Br). Indoor and outdoor measured levels were compared to the American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE) and health-based National Ambient Air Quality standards (NAAQS), respectively. For the priority metals, on the other hand, indoor measured values were compared to occupational standards recommended by the National Institute of Occupational Safety and Health (NIOSH) and Occupational Safety and Health Administration (OSHA)

  15. Atmospheric processing outside clouds increases soluble iron in mineral dust.

    Science.gov (United States)

    Shi, Zongbo; Krom, Michael D; Bonneville, Steeve; Benning, Liane G

    2015-02-03

    Iron (Fe) is a key micronutrient regulating primary productivity in many parts of the global ocean. Dust deposition is an important source of Fe to the surface ocean, but most of this Fe is biologically unavailable. Atmospheric processing and reworking of Fe in dust aerosol can increase the bioavailable Fe inputs to the ocean, yet the processes are not well understood. Here, we experimentally simulate and model the cycling of Fe-bearing dust between wet aerosol and cloud droplets. Our results show that insoluble Fe in dust particles readily dissolves under acidic conditions relevant to wet aerosols. By contrast, under the higher pH conditions generally relevant to clouds, Fe dissolution tends to stop, and dissolved Fe precipitates as poorly crystalline nanoparticles. If the dust-bearing cloud droplets evaporated again (returning to the wet aerosol stage with low pH), those neo-formed Fe nanoparticles quickly redissolve, while the refractory Fe-bearing phases continue to dissolve gradually. Overall, the duration of the acidic, wet aerosol stage ultimately increases the amount of potentially bioavailable Fe delivered to oceans, while conditions in clouds favor the formation of Fe-rich nanoparticles in the atmosphere.

  16. Iron Oxide Minerals in Atmospheric Dust and Source Sediments-Studies of Types and Properties to Assess Environmental Effects

    Science.gov (United States)

    Reynolds, R. L.; Goldstein, H. L.; Moskowitz, B. M.; Till, J. L.; Flagg, C.; Kokaly, R. F.; Munson, S.; Landry, C.; Lawrence, C. R.; Hiza, M. M.; D'Odorico, P.; Painter, T. H.

    2011-12-01

    Ferric oxide minerals in atmospheric dust can influence atmospheric temperatures, accelerate melting of snow and ice, stimulate marine phytoplankton productivity, and impact human health. Such effects vary depending on iron mineral type, size, surface area, and solubility. Generally, the presence of ferric oxides in dust is seen in the red, orange, or yellow hues of plumes that originate in North Africa, central and southwest Asia, South America, western North America, and Australia. Despite their global importance, these minerals in source sediments, atmospheric dust, and downwind aeolian deposits remain poorly described with respect to specific mineralogy, particle size and surface area, or presence in far-traveled aerosol compounds. The types and properties of iron minerals in atmospheric dust can be better understood using techniques of rock magnetism (measurements at 5-300 K), Mössbauer and high-resolution visible and near-infrared reflectance spectroscopy; chemical reactivity of iron oxide phases; and electron microscopy for observing directly the ferric oxide coatings and particles. These studies can elucidate the diverse environmental effects of iron oxides in dust and can help to identify dust-source areas. Dust-source sediments from the North American Great Basin and Colorado Plateau deserts and the Kalahari Desert, southern Africa, were used to compare average reflectance values with a magnetic parameter (hard isothermal remanent magnetization, HIRM) for ferric oxide abundance. Lower reflectance values correspond strongly with higher HIRM values, indicating that ferric oxides (hematite or goethite, or both) contribute to absorption of solar radiation in these sediments. Dust deposited to snow cover of the San Juan Mountains (Colorado) and Wasatch Mountains (Utah) was used to characterize dust composition compared with properties of sediments exposed in source-areas identified from satellite retrievals. Results from multiple methods indicate that

  17. The carbon footprint of indoor Cannabis production

    International Nuclear Information System (INIS)

    Mills, Evan

    2012-01-01

    The emergent industry of indoor Cannabis production – legal in some jurisdictions and illicit in others – utilizes highly energy intensive processes to control environmental conditions during cultivation. This article estimates the energy consumption for this practice in the United States at 1% of national electricity use, or $6 billion each year. One average kilogram of final product is associated with 4600 kg of carbon dioxide emissions to the atmosphere, or that of 3 million average U.S. cars when aggregated across all national production. The practice of indoor cultivation is driven by criminalization, pursuit of security, pest and disease management, and the desire for greater process control and yields. Energy analysts and policymakers have not previously addressed this use of energy. The unchecked growth of electricity demand in this sector confounds energy forecasts and obscures savings from energy efficiency programs and policies. While criminalization has contributed to the substantial energy intensity, legalization would not change the situation materially without ancillary efforts to manage energy use, provide consumer information via labeling, and other measures. Were product prices to fall as a result of legalization, indoor production using current practices could rapidly become non-viable. - Highlights: ► The emergent industry of indoor Cannabis production utilizes highly energy intensive processes and is highly inefficient. ► In the United States, this represents an annual energy expenditure of $6 billion. ► One kg of final product is associated with emissions of 4600 kg of CO 2 emissions to the atmosphere. ► Aggregate U.S. emissions are equivalent those of 3 million cars. ► Energy analysts and policymakers have not previously addressed this use of energy.

  18. Study of occupational health impact of atmospheric pollution on exposed workers at an iron and steel complex by using neutron activation analysis of scalp hair

    International Nuclear Information System (INIS)

    Chai, Z.F.; Qian, Q.F.; Feng, X.Q.; Zhang, P.Q.; Liu, N.Q.; Feng, W.Y.

    2004-01-01

    The occupational health impact of atmospheric pollution on exposed workers at one iron and steel complex was studied by instrumental neutron activation analysis of workers' hair samples and medical examination. The experimental results indicate that there is a positive correlation between the high inhalation amounts of iron and other trace elements by the exposed workers and the symptom of their high blood pressure and hypoglycemia, which implies that the atmospheric environment polluted by iron and steel industry has an adverse health impact on the exposed workers. The measures to relieve and abate the occupational diseases caused by air-borne particulate matter should be taken. (author)

  19. Physicochemical Characterization of Nanoparticles from Indoor Ventilation Systems and Their Potential Health Impacts

    Science.gov (United States)

    Dalton, G.; Revkin, A. C.; Gruenspecht, H.; Ramanathan, V.; Brown, M. A.; Nagel, D. C.; Revkin, A. C.; Umo, N. S.; Oseghe, E. O.

    2016-12-01

    Indoor air pollution remains a major concern to humans considering that we spend about 90% of our daily lives indoors [1,2]. Air pollutants, which ranges from gases to aerosol particles, vary considerably from our homes, public/work places and confined environments such as cars. They can impact on our health depending on the nature and concentration of the pollutants as well as the duration of exposure [3,4]. Particulate matter (PM), which is one of the major air pollutant markers, is present indoors and can be circulated for days to months within a confined space by the ventilation systems. In this study, both physical and chemical compositional evaluation of PM2.5 - 10 was carried out and the recirculation model of these particulates is presented based on the study of some ventilation systems such as air conditioners, cooling vents, and fans. For the first time, it is shown that the compositional variability of PM does not just depend on the source or the ongoing activities in the confined space but also on the recirculation time. Mineral dust particles were found to be dominant, some mixed with organics and soot or BC particles; heavy metals such as lead (Pb), cadmium (Cd), nickel (Ni), iron (Fe) and others were also analysed from the collected PM. Ventilation systems trap these particulates and do recirculate them over time and this can increase their toxicities and influences their composition. From this study, it can be suggested that regular cleaning of ventilation systems and flushing closed spaces with fresh air may become the most effective ways of controlling the concentration of PM in closed spaces with ventilation units such as indoors and cars. [1] H. K. Lai, et al., Atmospheric Environment 38 (37)(2004). [2] N.E. Klepeis, et al., J. of Exposure Analysis and Environmental Epidemiology 11(2001). [3] N. Bruce, et al., Bul. of the World Health Organization, 78 (9)(2000). [4] K.A. Miller, et al, The New England Journal of Medicine 356 (2007).

  20. Investigation of time-resolved atmospheric conditions and indoor/outdoor particulate matter concentrations in homes with gas and biomass cook stoves in Nogales, Sonora, Mexico.

    Science.gov (United States)

    Holmes, Heather A; Pardyjak, Eric R

    2014-07-01

    This paper reports findings from a case study designed to investigate indoor and outdoor air quality in homes near the United States-Mexico border During the field study, size-resolved continuous particulate matter (PM) concentrations were measured in six homes, while outdoor PM was simultaneously monitored at the same location in Nogales, Sonora, Mexico, during March 14-30, 2009. The purpose of the experiment was to compare PM in homes using different fuels for cooking, gas versus biomass, and to obtain a spatial distribution of outdoor PM in a region where local sources vary significantly (e.g., highway, border crossing, unpaved roads, industry). Continuous PM data were collected every 6 seconds using a valve switching system to sample indoor and outdoor air at each home location. This paper presents the indoor PM data from each home, including the relationship between indoor and outdoor PM. The meteorological conditions associated with elevated ambient PM events in the region are also discussed. Results indicate that indoor air pollution has a strong dependence on cooking fuel, with gas stoves having hourly averaged median PM3 concentrations in the range of 134 to 157 microg m(-3) and biomass stoves 163 to 504 microg m(-1). Outdoor PM also indicates a large spatial heterogeneity due to the presence of microscale sources and meteorological influences (median PM3: 130 to 770 microg m(-3)). The former is evident in the median and range of daytime PM values (median PM3: 250 microg m(-3), maximum: 9411 microg m(-3)), while the meteorological influences appear to be dominant during nighttime periods (median PM3: 251 microg m(-3), maximum: 10,846 microg m(-3)). The atmospheric stability is quantified for three nighttime temperature inversion episodes, which were associated with an order of magnitude increase in PM10 at the regulatory monitor in Nogales, AZ (maximum increase: 12 to 474 microg m(-3)). Implications: Regulatory air quality standards are based on outdoor

  1. Effects of indoor residence on radiation doses from routine releases of radionuclides to the atmosphere

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1980-01-01

    Dose reduction factors from indoor residence during routine releases of radionuclides to the atmosphere were studied using models that are suitable for application to arbitrary source terms. Dose reduction factors for internal exposure to inhaled radionuclides account for air ventilation and deposition on inside building surfaces. Estimated internal dose reduction factors are approx. 0.2 to 0.8 for particulates and 0.07 to 0.4 for radioiodine. Dose reduction factors for external photon exposure from airborne and surface-deposited sources are based on the point-kernel integration method. Values for source terms from a fuel reprocessing plant and a hypothetical reactor accident are within a factor of 2 of the value 0.5 adopted by the US Nuclear Regulatory Commission (NRC) for population dose assessments. For the release at Three Mile Island nuclear station, however, the external dose reduction factor may be an order of magnitude less than the value adopted by the NRC

  2. The Health Risks of Belgian Illicit Indoor Cannabis Plantations.

    Science.gov (United States)

    Vanhove, Wouter; Cuypers, Eva; Bonneure, Arne-Jan; Gotink, Joachim; Stassen, Mirna; Tytgat, Jan; Van Damme, Patrick

    2018-04-10

    We assessed the prevalence of potential health hazards to intervention staff and cannabis growers in Belgian indoor cannabis plantations. Surface mold swab samples were taken at 16 Belgian indoor plantations contained mostly Penicillium sp. and Aspergillus sp. However, their precise health impact on intervention staff and illicit growers is unclear as no molds spore concentrations were measured. Atmospheric gas monitoring in the studied cannabis plantations did not reveal dangerous toxic substances. Health symptoms were reported by 60% of 221 surveyed police, but could not be linked to specific plantation characteristics. We conclude that Belgian indoor cannabis plantations pose a potential health threat to growers and intervention staff. AS there are currently no clear safety guidelines for seizure and dismantling of Belgian indoor cannabis plantations, we recommend first responders to follow strict safety rules when entering the growth rooms, which include wearing appropriate personal protective equipment. © 2018 American Academy of Forensic Sciences.

  3. Effects of atmospheric gas composition and temperature on the gasification of coal in hot briquetting carbon composite iron ore

    Energy Technology Data Exchange (ETDEWEB)

    Ueki, Y.; Kanayama, M.; Maeda, T.; Nishika, K.; Shimizu, M. [Kyushu University, Fukuoka (Japan). Dept. of Materials Science & Engineering

    2007-01-15

    The gasification behavior of carbon composite iron ore produced by hot briquetting process was examined under various gas atmospheres such as CO-N{sub 2}, CO{sub 2}-N, and CO-CO{sub 2} at various temperatures. The gasification of coal was affected strongly by atmospheric gas concentration and reaction temperature. Kinetic analysis in various gas atmospheres was carried out by using the first order reaction model, which yields the straight line relation between reaction rate constants for the gasification of coal and the gas concentration. Therefore, reaction rate constants for the gasification of coal in CO-CO{sub 2}-N{sub 2} gas atmosphere were derived.

  4. Indoor Thermal Environment in Tropical Climate Residential Building

    Directory of Open Access Journals (Sweden)

    Jamaludin Nazhatulzalkis

    2014-01-01

    Full Text Available Indoor thermal environment is one of the criteria in sustainable building. This criterion is important in ensuring a healthy indoor environment for the occupants. The consideration of environmental concerns at the early design stage would effectively integrate the sustainability of the building environment. Global climate changes such as global warming do affect human comfort since people spend most of their time and activities in the building. The increasing of urban population required additional housing for households, as well as places to shop, office and other facilities. Occupants are now more conscious the importance of sustainability for a better quality of life. Good thermal environment is essential for human wellness and comfort. A residential environment will influence residents’ health and safety. The global warming increase the earth’s temperature and greenhouse emission to the atmosphere cause adverse effects to the outdoor environment. Residential developments modify the materials, structure and energy balance in urban climate effects of human economic activities. As an indoor environment is influenced by the outdoor condition, the factors affecting indoor thermal environment are crucial in improving a comfortable and healthy environment in residential building. The microclimatic of a site such as temperature and relative humidity, and wind movement led to the variation of indoor thermal environment in the building.

  5. Iron availability, nitrate uptake, and exportable new production in the subarctic Pacific. [phytoplankton population growth support and atmospheric CO2 removal

    Science.gov (United States)

    Banse, Karl

    1991-01-01

    This paper presents a critique of experimental data and papers by Martin et al. (1989, 1990), who suggested that the phytoplankton growth is iron-limited and that, small additions of iron to large subarctic ocean areas might be a way of removing significant amounts of atmospheric CO2 by increasing phytoplancton growth. Data are presented to show that, in the summer of 1987, the phytoplankton assemblage as a whole was not iron limited, as measured by the bulk removal of nitrate or by the increase of chlorophyll. It is suggested that grazing normally prevents the phytoplankton from reaching concentrations that reduce the iron (and nitrate) to levels that depress division rates drastically.

  6. Meteorological factors influencing on the radon concentrations in indoor and outdoor airs

    International Nuclear Information System (INIS)

    Kojima, Hiroshi

    1989-01-01

    Factors influencing radon concentrations in indoor and outdoor airs are discussed. A balance between source and loss is required in determining the radon concentration. Source refers to as the outdoor and indoor exhalation rate from the ground and the building materials. Loss is caused by turbulent diffusion outdoors and ventilation indoors. A significant factor influencing the exhalation rate of indoor and outdoor radon may be the change in atmospheric pressure. A drop of pressure feeds the high concentration air under the ground or building materials into the open air, and contributes to the increased exhalation rate. The exhalation rate of radon closely depends on the moisture content of the ground or building materials. Up to a certain level of moisture, the radon exhalation increases with increasing moisture content because the emanation power increases by a recoil effect of a fluid present in the internal pores of the materials. Beyond a certain level of moisture, the exhalation decreases rapidly because the pores are filled with water. Radon exhalated from the ground is spread out by turbulent diffusion. The turbulent diffusion may be related to wind velocity and the lapse rate of temperature. There is a remakable difference between indoor and outdoor radon concentrations. The ventilation rate of the house exerted a great effect upon the indoor radon concentration. The ventilation rate is influenced by meteorological factors together with human activities. Of such factors, wind velocity and temperature gradient between indoor and outdoor airs may be the most significant. The correlation coefficients between RaA or radon and some meteorological factors were calculated on the data from the long term measurements on radon and its decay products in and out of a house under normal living conditions. The changes in atmospheric pressure and wind velocity are found to be a significant factor in the variation of concentration of these nuclides. (N.K.)

  7. Updated atmospheric speciated mercury emissions from iron and steel production in China during 2000-2015

    Science.gov (United States)

    Wu, Qingru; Gao, Wei; Wang, Shuxiao; Hao, Jiming

    2017-09-01

    Iron and steel production (ISP) is one of the significant atmospheric Hg emission sources in China. Atmospheric mercury (Hg) emissions from ISP during 2000-2015 were estimated by using a technology-based emission factor method. To support the application of this method, databases of Hg concentrations in raw materials, technology development trends, and Hg removal efficiencies of air pollution control devices (APCDs) were constructed through national sampling and literature review. Hg input to ISP increased from 21.6 t in 2000 to 94.5 t in 2015. In the various types of raw materials, coking coal and iron concentrates contributed 35-46 and 25-32 % of the total Hg input. Atmospheric Hg emissions from ISP increased from 11.5 t in 2000 to 32.7 t in 2015 with a peak of 35.6 t in 2013. Pollution control promoted the increase in average Hg removal efficiency, from 47 % in 2000 to 65 % in 2015. During the study period, sinter/pellet plants and blast furnaces were the largest two emission processes. However, emissions from roasting plants and coke ovens cannot be ignored, which accounted for 22-34 % of ISP's emissions. Overall, Hg speciation shifted from 50/44/6 (gaseous elemental Hg (Hg0)/gaseous oxidized Hg (HgII)/particulate-bound Hg (Hgp)) in 2000 to 40/59/1 in 2015, which indicated a higher proportion of Hg deposition around the emission points. Future emissions of ISP were expected to decrease based on the comprehensive consideration crude-steel production, steel scrap utilization, energy saving, and pollution control measures.

  8. INDOOR SUBSPACING TO IMPLEMENT INDOORGML FOR INDOOR NAVIGATION

    Directory of Open Access Journals (Sweden)

    H. Jung

    2015-10-01

    Full Text Available According to an increasing demand for indoor navigation, there are great attempts to develop applicable indoor network. Representation for a room as a node is not sufficient to apply complex and large buildings. As OGC established IndoorGML, subspacing to partition the space for constructing logical network is introduced. Concerning subspacing for indoor network, transition space like halls or corridors also have to be considered. This study presents the subspacing process for creating an indoor network in shopping mall. Furthermore, categorization of transition space is performed and subspacing of this space is considered. Hall and squares in mall is especially defined for subspacing. Finally, implementation of subspacing process for indoor network is presented.

  9. Indoor Subspacing to Implement Indoorgml for Indoor Navigation

    Science.gov (United States)

    Jung, H.; Lee, J.

    2015-10-01

    According to an increasing demand for indoor navigation, there are great attempts to develop applicable indoor network. Representation for a room as a node is not sufficient to apply complex and large buildings. As OGC established IndoorGML, subspacing to partition the space for constructing logical network is introduced. Concerning subspacing for indoor network, transition space like halls or corridors also have to be considered. This study presents the subspacing process for creating an indoor network in shopping mall. Furthermore, categorization of transition space is performed and subspacing of this space is considered. Hall and squares in mall is especially defined for subspacing. Finally, implementation of subspacing process for indoor network is presented.

  10. The airborne metagenome in an indoor urban environment.

    Directory of Open Access Journals (Sweden)

    Susannah G Tringe

    Full Text Available The indoor atmosphere is an ecological unit that impacts on public health. To investigate the composition of organisms in this space, we applied culture-independent approaches to microbes harvested from the air of two densely populated urban buildings, from which we analyzed 80 megabases genomic DNA sequence and 6000 16S rDNA clones. The air microbiota is primarily bacteria, including potential opportunistic pathogens commonly isolated from human-inhabited environments such as hospitals, but none of the data contain matches to virulent pathogens or bioterror agents. Comparison of air samples with each other and nearby environments suggested that the indoor air microbes are not random transients from surrounding outdoor environments, but rather originate from indoor niches. Sequence annotation by gene function revealed specific adaptive capabilities enriched in the air environment, including genes potentially involved in resistance to desiccation and oxidative damage. This baseline index of air microbiota will be valuable for improving designs of surveillance for natural or man-made release of virulent pathogens.

  11. The Airborne Metagenome in an Indoor Urban Environment

    Energy Technology Data Exchange (ETDEWEB)

    Tringe, Susannah; Zhang, Tao; Liu, Xuguo; Yu, Yiting; Lee, Wah Heng; Yap, Jennifer; Yao, Fei; Suan, Sim Tiow; Ing, Seah Keng; Haynes, Matthew; Rohwer, Forest; Wei, Chia Lin; Tan, Patrick; Bristow, James; Rubin, Edward M.; Ruan, Yijun

    2008-02-12

    The indoor atmosphere is an ecological unit that impacts on public health. To investigate the composition of organisms in this space, we applied culture-independent approaches to microbes harvested from the air of two densely populated urban buildings, from which we analyzed 80 megabases genomic DNA sequence and 6000 16S rDNA clones. The air microbiota is primarily bacteria, including potential opportunistic pathogens commonly isolated from human-inhabited environments such as hospitals, but none of the data contain matches to virulent pathogens or bioterror agents. Comparison of air samples with each other and nearby environments suggested that the indoor air microbes are not random transients from surrounding outdoor environments, but rather originate from indoor niches. Sequence annotation by gene function revealed specific adaptive capabilities enriched in the air environment, including genes potentially involved in resistance to desiccation and oxidative damage. This baseline index of air microbiota will be valuable for improving designs of surveillance for natural or man-made release of virulent pathogens.

  12. Role of Automobile Exhaust on the Photoreductive Solubilization of Atmospheric Iron

    Science.gov (United States)

    Haynes, J.; Majestic, B. J.; Cutler, E.

    2016-12-01

    Atmospheric iron (Fe) plays an essential role in the carbon cycle, affecting the Earth's energy balance and human health. Fe catalyzes oxidations of organic carbon species and serves as a limiting nutrient for phytoplankton in about half of the world's oceans. Wind-blown dust is the major source of atmospheric insoluble Fe while urban areas are correlated with relatively high percentages of soluble Fe. The occurrence of elevated levels of soluble Fe near urban and industrial regions suggests a correlation between Fe solubilization and organic combustion products, including polycyclic aromatic hydrocarbons (PAH). Fossil fuel consumption for internal combustion engines produce atmospheric PAH as a major component of automobile exhaust. Under light, PAH transform into oxidized components such as ketones and carboxylic acids. For example, phthalic acid (formed from naphthalene) inhibits Fe oxidation reactions and therefore may contribute to Fe reduction and increased solubility. The wind-blown dust and PAH-containing combustion products undergo long-range atmospheric transport leading to mixing and metal-organic interactions. The current study focuses on how a saturated PAH suspension affects the production of soluble Fe. Reactions of soil-based Fe and saturated solutions of PAH are performed under controlled conditions simulating natural sunlight. Samples are analyzed by ICPMS for soluble Fe before and after solar exposure reactions; soluble Fe is separated from total Fe by filtration and total Fe by acid-assisted microwave digestion. Data indicate an increase in Fe solubility (1.2% to 4.2%) in the presence of PAH, as compared to soil in water alone, and an even greater increase in Fe solubility (4.2% to 8.4%) when exposed to solar radiation. Research is ongoing to determine the dependence of oxidized PAH on kinetic and overall Fe solubility.

  13. Mercury persistence in indoor environments in the Amazon Region, Brazil

    International Nuclear Information System (INIS)

    Bastos, W.R.; Freitas Fonseca, M. de; Pinto, F.N.; Freitas Rebelo, Mauro de; Silva dos Santos, Sergio; Gloria da Silveira, Ene; Torres, J.P.M.; Malm, Olaf; Pfeiffer, W.C.

    2004-01-01

    We evaluated the indoor atmospheric Hg contamination in gold trade shops in two Brazilian cities of the Legal Amazon area using the Spanish moss (Tillandsia usneoides, Bromeliaceae) as a sentinel species. Plants inside plastic cages were exposed to a controlled atmosphere to evaluate the rate of Hg retention over time and then distributed in several stores with different characteristics to enable a relative comparison. Hg concentrations were determined by cold vapor atomic absorption spectrophotometry. Plants exposed in active stores with good air circulation exhibited lower levels. Ex-gold trade shops that were kept closed for long periods exhibited higher values. Stores that have been restored before being transformed into new businesses exhibited lower values than nonrestored ones. Direct measurements suggest that indoor Hg air concentrations were below the threshold limit recommended by the World Health Organization to occupational exposure; nevertheless, restoring ex-gold trade shops could ensure a healthier working environment

  14. Mercury persistence in indoor environments in the Amazon region, Brazil.

    Science.gov (United States)

    Bastos, Wanderley Rodrigues; Fonseca, Márlon de Freitas; Pinto, Fernando Neves; Rebelo, Mauro de Freitas; dos Santos, Sérgio Silva; da Silveira, Ene Glória; Torres, João Paulo Machado; Malm, Olaf; Pfeiffer, Wolfgang Christian

    2004-10-01

    We evaluated the indoor atmospheric Hg contamination in gold trade shops in two Brazilian cities of the Legal Amazon area using the Spanish moss (Tillandsia usneoides, Bromeliaceae) as a sentinel species. Plants inside plastic cages were exposed to a controlled atmosphere to evaluate the rate of Hg retention over time and then distributed in several stores with different characteristics to enable a relative comparison. Hg concentrations were determined by cold vapor atomic absorption spectrophotometry. Plants exposed in active stores with good air circulation exhibited lower levels. Ex-gold trade shops that were kept closed for long periods exhibited higher values. Stores that have been restored before being transformed into new businesses exhibited lower values than nonrestored ones. Direct measurements suggest that indoor Hg air concentrations were below the threshold limit recommended by the World Health Organization to occupational exposure; nevertheless, restoring ex-gold trade shops could ensure a healthier working environment.

  15. Lead and cadmium in indoor air and the urban environment

    International Nuclear Information System (INIS)

    Komarnicki, Guenter J.K.

    2005-01-01

    The present study was conducted to find potential terrestrial biomonitors for heavy metals in indoor air in an urban environment. TSP, PM 10 , and PM 2.5 were collected in three retirement facilities in the urban area of Vienna. In addition, particulate matter and soil, vegetation, and isopods (Porcellio scaber L.) were collected in the adjacent garden areas. Aerosols were sampled with a low-volume air sampler. The sampled materials were wet ashed and total lead and cadmium contents were determined. Water-soluble heavy metal concentrations were measured in aqueous extracts from air exposed filters, soil, and vegetation. Lead and cadmium were analyzed by graphite furnace AAS. Lead contents in the vegetation were inferred from water-soluble lead in soils. Lead in isopods generally reflected the contents in vegetation. Cadmium in plants probably derived from soil solutions as well as from atmospheric input. Isopods reflected the total cadmium contents in soils. Particulate matter was dominated by PM 2.5 , both with respect to mass concentrations and to heavy metal contents. The indoor aerosol was found to be influenced by human activity, indoor sources, and outdoor particles. Relationships between indoor airborne heavy metals and the contents in vegetation (lead and cadmium: positive) and isopods (lead: negative) were identified to have the potential for biomonitoring indoor air quality. - Urban vegetation and isopods are potential indicators for indoor aerial heavy metals

  16. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres. Progress report, July 1, 1992--March 31, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Hopke, P.K.

    1992-07-01

    This report describes studies on the chemical and physical behavior of the {sup 218}Po atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity in the sub-10 nm size range result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and its dose to the cells in the respiratory tract are to be fully assessed. The specific tasks of the controlled laboratory studies are to determine the formation rates of {center_dot}OH radicals formed by the radiolysis of air following radon decay, to examine the formation of particles by the radiolytic oxidation of substances like SO{sub 2} ethylene, and H{sub 2}S to lower vapor pressure compounds and determine the role of gas phase additives such as H{sub 2}O and NH{sub 3} in determining the particle size, to measure the rate of ion-induced nucleation using a thermal diffusion cloud chamber, and to measure the neutralization rate of {sup 218}Po{sub x}{sup +} in O{sub 2} at low radon concentrations. Tasks of the exposure studies in occupied indoor spaces are to initiate measurements of the activity size distributions in actual homes with occupants present so that the variability of the indoor activity size distributions can be assessed with respect to indoor aerosol sources and general lifestyle variations of the occupants, to initiate a prospective study of the utility of measurement of deposited {sup 210}Pb embedded in glass surfaces as a measure of the long-term, integrated exposure of the population to radon, and to develop the methodology to determine the hygroscopicity of the indoor aerosol so that the changes in deposition efficiency of the radioactive indoor aerosol with hygroscopic growth in the respiratory tract can be assessed.

  17. Source, concentration, and distribution of elemental mercury in the atmosphere in Toronto, Canada

    International Nuclear Information System (INIS)

    Cairns, Elaine; Tharumakulasingam, Kavitharan; Athar, Makshoof; Yousaf, Muhammad; Cheng, Irene; Huang, Y.; Lu, Julia; Yap, Dave

    2011-01-01

    Atmospheric gaseous elemental mercury [GEM] at 1.8, 4, and 59 m above ground, in parking lots, and in indoor and outdoor air was measured in Toronto City, Canada from May 2008-July 2009. The average GEM value at 1.8 m was 1.89 ± 0.62 ng m -3 . The GEM values increased with elevation. The average GEM in underground parking lots ranged from 1.37 to 7.86 ng m -3 and was higher than those observed from the surface parking lots. The GEM in the indoor air ranged from 1.21 to 28.50 ng m -3 , was higher in the laboratories than in the offices, and was much higher than that in the outdoor air. All these indicate that buildings serve as sources of mercury to the urban atmosphere. More studies are needed to estimate the contribution of urban areas to the atmospheric mercury budget and the impact of indoor air on outdoor air quality and human health. - Highlights: → Buildings served as mercury sources to urban atmosphere. → Atmospheric mercury level increased with increasing height in the street canyon. → Emission from vehicles and ground surfaces was not the major sources of Hg to urban air. → Mercury levels were higher in indoor than outdoor air and in laboratories than in offices. → Mercury levels were higher in the outdoor air near building walls. - Buildings serve as sources of gaseous elemental mercury and research is needed to quantify the emission and to assess the impact of indoor air on outdoor air quality and human health.

  18. Implications of chiral signatures of PCBs in soil, outdoor, and indoor air in the West Midlands conurbation, UK

    Energy Technology Data Exchange (ETDEWEB)

    Jamshidi, A.; Hazrati, S.; Harrad, S. [Birmigham Univ., Birmingham (United Kingdom)

    2005-07-01

    This paper provided additional data related to a study conducted to determine chiral signatures of polychlorinated biphenyl (PCBs) in outdoor air and topsoil from urban, rural and semi-urban locations in the United Kingdom's West Midlands conurbation. The study hypothesized that the ventilation of PCB-contaminated indoor air was a principal source of the racemic PCBs observed in outdoor air. Measurements of chiral signatures of PCBs in indoor air were measured. Chiral signatures of PCB 136 and 149 were expressed in terms of enantiomeric excess. Outdoor air and soil samples were collected from 10 sites located on a southwest to northeast transect of the conurbation at intervals of between 3 and 17 km. Topsoil and air samples were collected on a monthly basis to examine seasonal variability. Passive air samplers were used to provide a time-integrated atmospheric signal over each sampling period. Twenty indoor air samples were collected using PUF disk samplers. All samples were then extracted, purified, and subjected to enantioselective gas chromatography and mass spectrometry (GC-MS) analysis. Results suggested that chiral signatures in outdoor air for all target PCBs were racemic at all locations, and confirmed earlier hypotheses that the ventilation of PCB-contaminated indoor air is the principal source of PCB contamination in the urban atmosphere. It was concluded that actions to reduce PCB stocks remaining in use in indoor environments will result in a significant reduction in atmospheric concentrations. 7 refs., 2 tabs., 1 fig.

  19. INDOOR-OUTDOOR AEROSOL CONCENTRATIONS IN TWO PORTUGUESE CITIES AND THE GLOBAL WARMING SCENARIO

    Energy Technology Data Exchange (ETDEWEB)

    Antonio F. Miguel; A. Heitor Reis [Department of Physics, University of Evora (Portugal); Marta Melgao [Geophysics Centre of Evora (Portugal)

    2008-09-30

    Aerosols play a major role both in climate change and in air quality. They affect climate through interfering with radiative transfer and hence the atmospheric temperature, and also the air quality. Many epidemiological studies have confirmed that a relation exists between elevated aerosol particle concentration and adverse human health effects. Aerosol particle number and size distributions were measured both indoors and outdoors in the urban areas of Evora and Lisbon. We investigated the indoor-to-outdoor relationship of aerosol particles and the aerosol size distributions. The impact of the occurrence of a residential fire in the aerosol size distribution is also analyzed. Finally, we speculate of how global increase in temperature can affect concentration of aerosols in the atmosphere, via increased boundary layer convection.

  20. Indoor air pollution

    International Nuclear Information System (INIS)

    Qureshi, I.H.

    2001-01-01

    Indoor air pollution is a potential risk to human health. Prolonged exposure to indoor pollutants may cause various infectious, allergic and other diseases. Indoor pollutants can emanate from a broad array of internal and external sources. Internal sources include building and furnishing materials, consumer and commercial products, office equipment, micro-organisms, pesticides and human occupants activities. External sources include soil, water supplies and outside makeup air. The main indoor air pollutants of concern are inorganic gases, formaldehyde and other volatile organic compounds, pesticides, radon and its daughters, particulates and microbes. The magnitude of human exposure to indoor pollutants can be estimated or predicted with the help of mathematical models which have been developed using the data from source emission testing and field monitoring of pollutants. In order to minimize human exposure to indoor pollutants, many countries have formulated guidelines / standards for the maximum permissible levels of main pollutants. Acceptable indoor air quality can be achieved by controlling indoor pollution sources and by effective ventilation system for removal of indoor pollutants. (author)

  1. Updated atmospheric speciated mercury emissions from iron and steel production in China during 2000–2015

    Directory of Open Access Journals (Sweden)

    Q. Wu

    2017-09-01

    Full Text Available Iron and steel production (ISP is one of the significant atmospheric Hg emission sources in China. Atmospheric mercury (Hg emissions from ISP during 2000–2015 were estimated by using a technology-based emission factor method. To support the application of this method, databases of Hg concentrations in raw materials, technology development trends, and Hg removal efficiencies of air pollution control devices (APCDs were constructed through national sampling and literature review. Hg input to ISP increased from 21.6 t in 2000 to 94.5 t in 2015. In the various types of raw materials, coking coal and iron concentrates contributed 35–46 and 25–32 % of the total Hg input. Atmospheric Hg emissions from ISP increased from 11.5 t in 2000 to 32.7 t in 2015 with a peak of 35.6 t in 2013. Pollution control promoted the increase in average Hg removal efficiency, from 47 % in 2000 to 65 % in 2015. During the study period, sinter/pellet plants and blast furnaces were the largest two emission processes. However, emissions from roasting plants and coke ovens cannot be ignored, which accounted for 22–34 % of ISP's emissions. Overall, Hg speciation shifted from 50/44/6 (gaseous elemental Hg (Hg0/gaseous oxidized Hg (HgII/particulate-bound Hg (Hgp in 2000 to 40/59/1 in 2015, which indicated a higher proportion of Hg deposition around the emission points. Future emissions of ISP were expected to decrease based on the comprehensive consideration crude-steel production, steel scrap utilization, energy saving, and pollution control measures.

  2. Variance of indoor radon concentration: Major influencing factors

    Energy Technology Data Exchange (ETDEWEB)

    Yarmoshenko, I., E-mail: ivy@ecko.uran.ru [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation); Vasilyev, A.; Malinovsky, G. [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation); Bossew, P. [German Federal Office for Radiation Protection (BfS), Berlin (Germany); Žunić, Z.S. [Institute of Nuclear Sciences “Vinca”, University of Belgrade (Serbia); Onischenko, A.; Zhukovsky, M. [Institute of Industrial Ecology UB RAS, Sophy Kovalevskoy, 20, Ekaterinburg (Russian Federation)

    2016-01-15

    Variance of radon concentration in dwelling atmosphere is analysed with regard to geogenic and anthropogenic influencing factors. Analysis includes review of 81 national and regional indoor radon surveys with varying sampling pattern, sample size and duration of measurements and detailed consideration of two regional surveys (Sverdlovsk oblast, Russia and Niška Banja, Serbia). The analysis of the geometric standard deviation revealed that main factors influencing the dispersion of indoor radon concentration over the territory are as follows: area of territory, sample size, characteristics of measurements technique, the radon geogenic potential, building construction characteristics and living habits. As shown for Sverdlovsk oblast and Niška Banja town the dispersion as quantified by GSD is reduced by restricting to certain levels of control factors. Application of the developed approach to characterization of the world population radon exposure is discussed. - Highlights: • Influence of lithosphere and anthroposphere on variance of indoor radon is found. • Level-by-level analysis reduces GSD by a factor of 1.9. • Worldwide GSD is underestimated.

  3. Real time corrosion monitoring in atmosphere using automated battery driven corrosion loggers

    DEFF Research Database (Denmark)

    Prosek, T.; Kouril, M.; Hilbert, Lisbeth Rischel

    2008-01-01

    diminishes due to corrosion. Zinc, iron, copper and nickel sensors at several thicknesses are available. Sensitivity of the corrosion measurement varies from 1 to 10 nm depending on the type and thickness of the sensor. Changes in the air corrosivity can be thus detected within hours or even tens of minutes......A logger enabling continuous measurement of corrosion rate of selected metals in indoor and outdoor atmospheres has been developed. Principle of the measurement method is based on the increasing electrical resistance of a measuring element made of the material concerned as its cross-sectional area....... The logger lifetime in medium corrosive environments is designed to be 2 years with full autonomy. Data on the sensor corrosion rate are available any time through GPRS connection or by a non-contact inductive reading without the need of retracting the logger from the exposure site....

  4. Indoor Chemistry

    DEFF Research Database (Denmark)

    Weschler, Charles J.; Carslaw, Nicola

    2018-01-01

    This review aims to encapsulate the importance, ubiquity, and complexity of indoor chemistry. We discuss the many sources of indoor air pollutants and summarize their chemical reactions in the air and on surfaces. We also summarize some of the known impacts of human occupants, who act as sources...... and sinks of indoor chemicals, and whose activities (e.g., cooking, cleaning, smoking) can lead to extremely high pollutant concentrations. As we begin to use increasingly sensitive and selective instrumentation indoors, we are learning more about chemistry in this relatively understudied environment....

  5. Indoor Environment Program

    International Nuclear Information System (INIS)

    Daisey, J.M.

    1993-06-01

    This paper reports progress during the year 1992 in the Indoor Environment Program in the Energy and Environment Division of Lawrence Berkeley Laboratory. Studies in the following areas are reported: energy performance and ventilation in buildings; physical and chemical characterization of indoor air pollutants; indoor radon; indoor air quality; exposure to indoor air pollutants and risk analysis. Pollutants of particular interest include: radon; volatile, semi-volatile and particulate organic compounds; and combustion emissions including environmental tobacco smoke, carbon monoxide, and nitrogen oxides

  6. Indoor air radon

    International Nuclear Information System (INIS)

    Cothern, C.R.

    1990-01-01

    This review concerns primarily the health effects that result from indoor air exposure to radon gas and its progeny. Radon enters homes mainly from the soil through cracks in the foundation and other holes to the geologic deposits beneath these structures. Once inside the home the gas decays (half-life 3.8 d) and the ionized atoms adsorb to dust particles and are inhaled. These particles lodge in the lung and can cause lung cancer. The introduction to this review gives some background properties of radon and its progeny that are important to understanding this public health problem as well as a discussion of the units used to describe its concentrations. The data describing the health effects of inhaled radon and its progeny come both from epidemiological and animal studies. The estimates of risk from these two data bases are consistent within a factor of two. The epidemiological studies are primarily for hard rock miners, although some data exist for environmental exposures. The most complete studies are those of the US, Canadian, and Czechoslovakian uranium miners. Although all studies have some deficiencies, those of major importance include uranium miners in Saskatchewan, Canada, Swedish iron miners, and Newfoundland fluorspar miners. These six studies provide varying degrees of detail in the form of dose-response curves. Other epidemiological studies that do not provide quantitative dose-response information, but are useful in describing the health effects, include coal, iron ore and tin miners in the UK, iron ore miners in the Grangesburg and Kiruna, Sweden, metal miners in the US, Navajo uranium miners in the US, Norwegian niobian and magnitite miners, South African gold and uranium miners, French uranium miners, zinc-lead miners in Sweden and a variety of small studies of environmental exposure. An analysis of the epidemiological studies reveals a variety of interpretation problem areas.172 references

  7. Source specific risk assessment of indoor aerosol particles

    Energy Technology Data Exchange (ETDEWEB)

    Koivisto, A.J.

    2013-05-15

    In the urban environment, atmospheric aerosols consist mainly of pollutants from anthropogenic sources. The majority of these originate from traffic and other combustion processes. A fraction of these pollutants will penetrate indoors via ventilation. However, indoor air concentrations are usually predominated by indoor sources due to the small amount of dilution air. In modern societies, people spend most of their time indoors. Thus, their exposure is controlled mainly by indoor concentrations from indoor sources. During the last decades, engineering of nanosized structures has created a new field of material science. Some of these materials have been shown to be potentially toxic to human health. The greatest potential for exposure to engineered nanomaterials (ENMs) occurs in the workplace during production and handling of ENMs. In an exposure assessment, both gaseous and particulate matter pollutants need to be considered. The toxicities of the particles usually depend on the source and age. With time, particle morphology and composition changes due to their tendency to undergo coagulation, condensation and evaporation. The PM exposure risk is related to source specific emissions, and thus, in risk assessment one needs to define source specific exposures. This thesis describes methods for source specific risk assessment of airborne particulate matter. It consists of studies related to workers' ENM exposures during the synthesis of nanoparticles, packing of agglomerated TiO{sub 2} nanoparticles, and handling of nanodiamonds. Background particles were distinguished from the ENM concentrations by using different measurement techniques and indoor aerosol modelings. Risk characterization was performed by using a source specific exposure and calculated dose levels in units of particle number and mass. The exposure risk was estimated by using non-health based occupational exposure limits for ENMs. For the nanosized TiO{sub 2}, the risk was also assessed from dose

  8. Study of the fallout of artificial iron-55. Application to the evaluation of the fallout of natural iron of stratospheric origin

    International Nuclear Information System (INIS)

    Hoang Chi Trach

    1969-01-01

    The object of this work is to study the iron-55 fallout to establish the world balance of this radioelement. The utilisation of this tracer enables the calculation of the input of natural iron of stratospheric origin to the Earth and the input through the atmosphere of natural iron to the oceans. We have shown that: iron-55 is essentially produced in nuclear explosions according to the 56 Fe(n,2n) 55 Fe reaction; the iron-55 fallout obeys a 'stratospheric pattern' with a decay period between 9 and 11 months; by surface unit and at the same latitude, this fallout is 3.5 times more important on the Eastern part of the Northern Atlantic than over France. By comparison with the strontium-90 fallout, we established the world balance of the iron-55 fallout in the 1962-1965 period. This balance amounts to approximately 50 mega-curies for the iron-55 introduced into the atmosphere; 25.3 mega-curies of which fall down on the Earth during this period. We estimated at 6 x 10 6 tons per year the input of natural iron of stratospheric origin to the Earth and at 1.2 x 10 7 tons per year the input through the atmosphere of natural iron to the oceans. This latter figure represents 13 to 38 per cent of the amount of iron incorporated annually in the pelagic sediments. (author) [fr

  9. Healthy indoors : achieving healthy indoor environments in Canada : Final report

    International Nuclear Information System (INIS)

    Anon

    2002-01-01

    A large proportion of the lives of Canadians is spent indoors, whether in vehicles, restaurants, shopping malls, offices or houses. The health of people working and living in those indoor settings might be damaged a a result, despite best efforts. Indoor pollution has been identified as one of the most serious risks to human health, according to numerous leading authorities, among them the American Lung Association, the United States Environmental Protection Agency, the Canada Mortgage and Housing Corporation (CMHC). A large number of cancer deaths are attributed to indoor pollution each year in the United States, as well as respiratory health problems. A causal link between certain indoor exposures and the development and provocation of asthma was established recently in a report on asthma and indoor air quality published by the National Academy of Sciences/Institute of Medicine. Exposure to indoor pollutants has also resulted in thousands of children experiencing elevated blood lead levels. Not enough attention is paid in Canada to pollution in buildings by government agencies, corporations and other non-governmental organizations and citizens. Not much seems to have changed in the past thirty years. An ambitious strategy by Pollution Probe was described in this document, listing the initial goals and measures required to achieve those goals. The creation of Healthy Indoors Partnership (HIP) was proposed to regroup all the stakeholders under the same umbrella. refs., tabs

  10. Iron and Prochlorococcus

    Science.gov (United States)

    2009-06-01

    including: acid -cleaned filters, filters rinsed with un-amended trace-metal clean seawater, and filters rinsed with the oxalate solution followed by...greatly influenced by the sources of iron to the marine environment, which include riverine input, hydrothermal upwelling, and atmospheric...deposition (Jickells et al, 2005). While the amount of iron introduced to the oceans from riverine and hydrothermal sources is high, precipitation occurs

  11. Atmospheric mercury cycles in northern Wisconsin

    Science.gov (United States)

    Watras, C. J.; Morrison, K. A.; Rubsam, J. L.; Rodger, B.

    Total gaseous mercury (TGM) in the lower atmosphere of northern Wisconsin exhibits strong annual and diurnal cycles similar to those previously reported for other rural monitoring sites across mid-latitude North America. Annually, TGM was highest in late winter and then gradually declined until late summer. During 2002-04, the average TGM concentration was 1.4 ± 0.2 (SD) ng m -3, and the amplitude of the annual cycle was 0.4 ng m -3 (˜30% of the long-term mean). The diurnal cycle was characterized by increasing TGM concentrations during the morning followed by decreases during the afternoon and night. The diurnal amplitude was variable but it was largest in spring and summer, when daily TGM oscillations of 20-40% were not uncommon. Notably, we also observed a diurnal cycle for TGM indoors in a room ventilated through an open window. Even though TGM concentrations were an order of magnitude higher indoors, (presumably due to historical practices within the building: e.g. latex paint, fluorescent lamps, thermometers), the diurnal cycle was remarkably similar to that observed outdoors. The indoor cycle was not directly attributable to human activity, the metabolic activity of vegetation or diurnal atmospheric dynamics; but it was related to changes in temperature and oxidants in outdoor air that infiltrated the room. Although there was an obvious difference in the proximal source of indoor and outdoor TGM, similarities in behavior suggest that common TGM cycles may be driven largely by adsorption/desorption reactions involving solid surfaces, such as leaves, snow, dust and walls. Such behavior would imply a short residence time for Hg in the lower atmosphere and intense recycling - consistent with the "ping-pong ball" or "multi-hop" conceptual models proposed by others.

  12. Anthropogenic combustion iron as a complex climate forcer.

    Science.gov (United States)

    Matsui, Hitoshi; Mahowald, Natalie M; Moteki, Nobuhiro; Hamilton, Douglas S; Ohata, Sho; Yoshida, Atsushi; Koike, Makoto; Scanza, Rachel A; Flanner, Mark G

    2018-04-23

    Atmospheric iron affects the global carbon cycle by modulating ocean biogeochemistry through the deposition of soluble iron to the ocean. Iron emitted by anthropogenic (fossil fuel) combustion is a source of soluble iron that is currently considered less important than other soluble iron sources, such as mineral dust and biomass burning. Here we show that the atmospheric burden of anthropogenic combustion iron is 8 times greater than previous estimates by incorporating recent measurements of anthropogenic magnetite into a global aerosol model. This new estimation increases the total deposition flux of soluble iron to southern oceans (30-90 °S) by 52%, with a larger contribution of anthropogenic combustion iron than dust and biomass burning sources. The direct radiative forcing of anthropogenic magnetite is estimated to be 0.021 W m -2 globally and 0.22 W m -2 over East Asia. Our results demonstrate that anthropogenic combustion iron is a larger and more complex climate forcer than previously thought, and therefore plays a key role in the Earth system.

  13. Indoor air quality

    DEFF Research Database (Denmark)

    Jensen, Trine Susanne; Recevska, Ieva

     The objective of the 35th specific agreement is to provide support to the EEA activities in Environment and Health (E&H) on the topic of indoor air quality. The specific objectives have been to provide an overview of indoor air related projects in EU and indoor air related policies as well...... as idenfiying "good practices" to reduce health impact of indoor air exposure and suggest areas for future improvements....

  14. Carbon-Supported Iron Oxide Particles

    DEFF Research Database (Denmark)

    Meaz, T.; Mørup, Steen; Koch, C. Bender

    1996-01-01

    A carbon black ws impregnated with 6 wt% iron using an aqueous solution of iron nitrate. The impregnated carbon was initially dried at 125 C. The effect of heating of the iron oxide phase was investigated at temperatures between 200 and 600 C using Mossbauer spectroscopy. All heat treatments were...... done in an oxygen-containing atmosphere. Ferrihydrite is formed and is stable at and below a temperature of 300 C. At 600 C small particles of maghemite is the dominant iron oxide. A transformation reaction is suggested....

  15. Iron-57 and iridium-193 Moessbauer spectroscopic studies of supported iron-iridium catalysts

    International Nuclear Information System (INIS)

    Berry, F.J.; Jobson, S.

    1988-01-01

    57 Fe and 193 Ir Moessbauer spectroscopy shows that silica- and alumina-supported iron-iridium catalysts formed by calcination in air contain mixtures of small particle iron(III) oxide and iridium(IV) oxide. The iridium dioxide in both supported catalysts is reduced in hydrogen to metallic iridium. The α-Fe 2 O 3 in the silica supported materials is predominantly reduced in hydrogen to an iron-iridium alloy whilst in the alumina-supported catalyst the iron is stabilised by treatment in hydrogen as iron(II). Treatment of a hydrogen-reduced silica-supported iron catalyst in hydrogen and carbon monoxide is accompanied by the formation of iron carbides. Carbide formation is not observed when the iron-iridium catalysts are treated in similar atmospheres. The results from the bimetallic catalysts are discussed in terms of the hydrogenation of associatively adsorbed carbon monoxide and the selectivity of supported iron-iridium catalysts to methanol formation. (orig.)

  16. Indoor multipath mitigation

    DEFF Research Database (Denmark)

    Dragünas, Kostas; Borre, Kai

    2010-01-01

    There are many applications that require continuous positioning in combined outdoor urban and indoor environments. GNSS has been used for a long time in outdoor environments, while indoor positioning is still a challenging task. One of the major degradations that GNSS receivers experience indoors...

  17. Atmospheric pollution: history, science and regulation

    Energy Technology Data Exchange (ETDEWEB)

    Jacobson, M.Z. [Stanford University, Stanford, CA (USA). Dept. of Civil and Environmental Engineering

    2002-07-01

    The book provides an introduction to the history and science of major air pollution issues. It begins with an introduction to the history of discovery of chemicals in the atmosphere, and moves on to a discussion of the evolution of the earth's atmosphere. It then discusses five major atmospheric pollution topics: urban outdoor air pollution, indoor air pollution, acid deposition, stratospheric ozone depletion, and global climate change. The book contains numerous student examples and problems and over 200 color illustrations and photographs.

  18. Indoor radon level in schools of Shillong, Meghalaya

    International Nuclear Information System (INIS)

    Saxena, A.; Sharma, Y.; Maibam, D.; Walia, D.; Diengdoh, E.

    2010-01-01

    Radon ( 222 Rn) in the atmosphere is the most important contributor to human exposure from natural sources. Radon is a noble inert gas; and it decays to radionuclides that are chemically active and relatively short lived. Inhalation of the short lived radon progeny imparts a radiation dose to the lung, to which an increased risk of lung cancer is attributed due to the alpha particle irradiation of the secretory and basal cells of the respiratory tract. The indoor radon concentration is dependent on the texture, porosity, permeability, water content of the soil underlying the structure and the radon behaviour in soils on aspects of geology and climate. The direct cause of high radon entry rates into structures exhibiting high indoor radon concentrations are fractures in bedrock formations, cracks in the soil, and similar inhomogeneities in the materials of the foundation of the structures. Other factors influencing indoor radon concentration includes exhalations from the walls and ceilings, building design and material, cracks and openings in the foundation of the buildings. The geological factors in the study area promote radon accumulation especially in buildings and dwellings. The world average annual effective dose in the indoor environments is 1.01 mSv.y -1 . The importance of radon level measurements in school buildings is of interest as children are more sensitive to radon exposure than adults. Hence, radon measurements in 10 schools have been undertaken in the present study

  19. Indoor air pollution

    International Nuclear Information System (INIS)

    Spengler, J.D.

    1985-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  20. Accelerated dissolution of iron oxides in ice

    Directory of Open Access Journals (Sweden)

    D. Jeong

    2012-11-01

    Full Text Available Iron dissolution from mineral dusts and soil particles is vital as a source of bioavailable iron in various environmental media. In this work, the dissolution of iron oxide particles trapped in ice was investigated as a new pathway of iron supply. The dissolution experiments were carried out in the absence and presence of various organic complexing ligands under dark condition. In acidic pH conditions (pH 2, 3, and 4, the dissolution of iron oxides was greatly enhanced in the ice phase compared to that in water. The dissolved iron was mainly in the ferric form, which indicates that the dissolution is not a reductive process. The extent of dissolved iron was greatly affected by the kind of organic complexing ligands and the surface area of iron oxides. The iron dissolution was most pronounced with high surface area iron oxides and in the presence of strong iron binding ligands. The enhanced dissolution of iron oxides in ice is mainly ascribed to the "freeze concentration effect", which concentrates iron oxide particles, organic ligands, and protons in the liquid like ice grain boundary region and accelerates the dissolution of iron oxides. The ice-enhanced dissolution effect gradually decreased when decreasing the freezing temperature from −10 to −196 °C, which implies that the presence and formation of the liquid-like ice grain boundary region play a critical role. The proposed phenomenon of enhanced dissolution of iron oxides in ice may provide a new pathway of bioavailable iron production. The frozen atmospheric ice with iron-containing dust particles in the upper atmosphere thaws upon descending and may provide bioavailable iron upon deposition onto the ocean surface.

  1. A View Indoors, Indoor Environment Division's e-Article Series

    Science.gov (United States)

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  2. Anti frictional materials iron-pig iron-brass manufacture using shaving waste products of pig-iron

    International Nuclear Information System (INIS)

    Nasamov, S. N.; Krivij, N.; Gudenau, H. W.; Babich, A. I.; Garcia, L. L.; Formoso, A.; Cores, A.

    2003-01-01

    Parts based on iron and steel powders are widely used in the manufacture of automobile and domestic equipment. This work was done to study the anti-friction properties of iron-pig iron-brass compositions of materials which were obtained by pressing and sintering from a mix of iron powders and industrial by products of cast-iron turnings, brass, talc and technical sulphur. Experiments were performed using cold pressure technology in the flowing matrix of the powder composite without solid lubricants. The subsequent sintering was carried out at 1200 degree centigree under isothermal conditions in a nitrogen atmosphere in the sintering zone during 1 h. The physical-mechanical and anti-friction properties were almost double by the active drainage of the gases from the compression mould. The study of the microstructure of the sintered materials showed that free cementite existed between the particle limits and around the pores. large agglomerations of dark inclusions could be observed, consisting of graphite, zinc and iron oxides, which were points of tension in the materials that reduce its durability and, therefore, its wear resistance to dry friction. (Author) 34 refs

  3. Indoor air quality

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Indoor Air Quality is rapidly becoming a major environmental concern because a significant amount of people spend a substantial amount of time in a variety of different indoor environments. Health effects from indoor pollutants fall into two categories: those that are experienced immediately after exposure and those that do not show up until years later. They are: radon, formaldehyde, asbestos, lead and household organic chemicals. The authors presented a source-by-source look at the most common indoor air pollutants, their potential health effects, and ways to reduce their levels in the home. There are three basic strategies to improve indoor air quality: one method is source control, another is through ventilation improvements, and the third is the utilization of some sort of mechanical device such as air cleaners

  4. Risk assessment of exposure to radon concentration in indoor atmosphere and drinking water of Shimoga city, Karnataka, India

    International Nuclear Information System (INIS)

    Rangaswamy, D.R.; Sannappa, J.; Srinivasa, E.

    2016-01-01

    The exposure of population to natural sources of radiation has become an important issue in terms of radiological protection. The major contribution of dose from natural radiation in normal background regions arises due to inhalation of alpha-emitting radon and thoron, and their progenies, which are ubiquitous in both indoor and outdoor environs. The aim of the present study is to measure indoor radon, thoron and their progeny levels in the dwellings of Shimoga city and radon concentration in drinking water and to estimate the annual effective dose. The indoor concentration of radon, thoron and their progeny was measured using Solid-State Nuclear Track Detectors (SSNTDs) based twin chamber dosimeter cups. The 222 Rn concentration in drinking water was estimated by the Emanometry technique

  5. Indoor Air Quality Analysis Using Deep Learning with Sensor Data

    Directory of Open Access Journals (Sweden)

    Jaehyun Ahn

    2017-10-01

    Full Text Available Indoor air quality analysis is of interest to understand the abnormal atmospheric phenomena and external factors that affect air quality. By recording and analyzing quality measurements, we are able to observe patterns in the measurements and predict the air quality of near future. We designed a microchip made out of sensors that is capable of periodically recording measurements, and proposed a model that estimates atmospheric changes using deep learning. In addition, we developed an efficient algorithm to determine the optimal observation period for accurate air quality prediction. Experimental results with real-world data demonstrate the feasibility of our approach.

  6. Coping with Indoor Air Pollution

    Science.gov (United States)

    ... Pollution > Coping with Indoor Air Pollution Font: Outdoor Pollution Indoor Air Pollution Asthma Triggers For Kids and Teachers Coping with Indoor Air Pollution Indoor air pollution is irritating to everyone: But people who ...

  7. Ocean iron fertilization

    Digital Repository Service at National Institute of Oceanography (India)

    Naqvi, S.W.A.; Smetacek, V.

    In 2009 and 2010, an Indo-German scientific expedition dusted the ocean with iron to stimulate the biological pump that captures atmosphereic carbon dioxide. Two onboard scientists tell the story of this controversial project. Besides raising...

  8. Indoor Tanning

    Science.gov (United States)

    ... proof that indoor tanning is safer than tanning outdoors. Indoor tanning systems give concentrated UV exposure regardless ... For example, it’s essential for promoting good bone health. While UV ... a tan to get that benefit. According to the Surgeon General, fair and light- ...

  9. Validation of a continuous flow method for the determination of soluble iron in atmospheric dust and volcanic ash.

    Science.gov (United States)

    Simonella, Lucio E; Gaiero, Diego M; Palomeque, Miriam E

    2014-10-01

    Iron is an essential micronutrient for phytoplankton growth and is supplied to the remote areas of the ocean mainly through atmospheric dust/ash. The amount of soluble Fe in dust/ash is a major source of uncertainty in modeling-Fe dissolution and deposition to the surface ocean. Currently in the literature, there exist almost as many different methods to estimate fractional solubility as researchers in the field, making it difficult to compare results between research groups. Also, an important constraint to evaluate Fe solubility in atmospheric dust is the limited mass of sample which is usually only available in micrograms to milligrams amounts. A continuous flow (CF) method that can be run with low mass of sediments (solubility studies on dust/ash. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Fluctuations in late Neoproterozoic atmospheric oxidation — Cr isotope chemostratigraphy and iron speciation of the late Ediacaran lower Arroyo del Soldado Group (Uruguay)

    DEFF Research Database (Denmark)

    Frei, Robert; Gaucher, Claudio; Stolper, Daniel

    2013-01-01

    Oxygenation of the Earth's atmosphere occurred in two major steps, near the beginning and near the end of the Proterozoic Eon (2500 to 542 Ma ago), but the details of this history are unclear. Chromium isotopes in iron-rich chemical sediments offer a potential to highlight fine-scale fluctuations...

  11. Enabling Indoor Location-Based Services

    DEFF Research Database (Denmark)

    Radaelli, Laura

    Indoor spaces have always attracted interest from different scientific disciplines. Relatively recent interest in indoor settings by computer scientists is driven in part by the increasing use of smartphones, which serve as a platform for service delivery and can generate extensive volumes...... of trajectory data that can be used to study how people actually use indoor spaces. In this dissertation, we contribute partial solutions that address challenges in indoor positioning and indoor trajectory management and analysis. The key enabler of indoor location-based services and indoor movement analysis...... is a well-functioning positioning system that can be easily deployed in most public places. Different technologies are able to provide indoor positioning with different accuracy and coverage, but it is difficult to find a technology that by itself can provide good positioning in the many different layouts...

  12. A modelling of the mechanisms occurring during the atmospheric corrosion of iron

    International Nuclear Information System (INIS)

    Marechal, L.; Perrin, S.; Hoerle, S.; Mazaudier, F.; Dillmann, P.

    2004-01-01

    In order to predict the long-term corrosion of metallic containers in storage conditions, a modelling of atmospheric corrosion of iron is proposed. This modelling takes into account the mechanisms which occur during the three stages of a wet-dry cycle. During the wetting stage, the reduction of lepidocrocite (g-FeOOH), a constituent of the rust layer, is considered to be the rate-limiting step of the corrosion. During the second stage of the cycle, the wet period, the reduction of dissolved oxygen on the lepidocrocite, previously reduced, is controlling the mechanism. The amount of oxidized metal depends on the quantity of reduced lepidocrocite and also on the oxygen diffusion in the electrolyte and the rust layer. At the end of the cycle, the blocking of the anodic sites is considered to describe the extinction of electrochemical corrosion during the drying. It appears that each stage of the cycle depends mainly on the chemical and morphological properties of the rust layer. (authors)

  13. Iron exclusion in rice genotypes as affected by different vapor pressure deficit conditions

    Directory of Open Access Journals (Sweden)

    Ram Kumar Shrestha

    2015-08-01

    Full Text Available Root iron (Fe exclusion capacity of four lowland rice genotypes were evaluated in increasing rate of Fe2+ stresses (0, 500, 1000 and 1500 mg/L in growing medium under the conditions of low and high vapor pressure deficit. Rice root excluded significantly higher amount of iron under dry atmospheric condition (655 mg Fe/g root dry matter than moist atmospheric condition (118 mg Fe/g root dry matter. But their iron exclusion capacity reduced when they were gradually exposed to the higher levels of Fe stress. Tolerant genotype such as TOX3107 excluded more iron when they were exposed to dry atmospheric condition.

  14. Indoor Climate Quality Assessment -

    DEFF Research Database (Denmark)

    Ansaldi, Roberta; Asadi, Ehsan; Costa, José Joaquim

    This Guidebook gives building professionals useful support in the practical measurements and monitoring of the indoor climate in buildings. It is evident that energy consumption in a building is directly influenced by required and maintained indoor comfort level. Wireless technologies for measure...... for measurement and monitoring have allowed a significantly increased number of possible applications, especially in existing buildings. The Guidebook illustrates several cases with the instrumentation of the monitoring and assessment of indoor climate.......This Guidebook gives building professionals useful support in the practical measurements and monitoring of the indoor climate in buildings. It is evident that energy consumption in a building is directly influenced by required and maintained indoor comfort level. Wireless technologies...

  15. Towards Mobile Information Systems for Indoor Space

    Directory of Open Access Journals (Sweden)

    Xiaoxiang Zhang

    2016-01-01

    Full Text Available With the rapid development of Internet of things (IOT and indoor positioning technologies such as Wi-Fi and RFID, indoor mobile information systems have become a new research hotspot. Based on the unique features of indoor space and urgent needs on indoor mobile applications, in this paper we analyze some key issues in indoor mobile information systems, including positioning technologies in indoor environments, representation models for indoor spaces, query processing techniques for indoor moving objects, and index structures for indoor mobile applications. Then, we present an indoor mobile information management system named IndoorDB. Finally, we give some future research topics about indoor mobile information systems.

  16. Environmental and indoor study of Radon concentration in San Joaquin area, Queretaro, Mexico, first results

    International Nuclear Information System (INIS)

    Hinojo Alonso, N.A.; Kotsarenko, A.; Yutsis, V.; Hernandez Silva, G.; Perego, P.; Fazio, M.; Grimalsky, V.; Koshevaya, S.; Foglia, F.; Cortes Silva, A.; García Martínez, R.; Martínez Reyes, J.; Norini, G.; Groppelli, G.

    2013-01-01

    A highly contaminated zone with a maximum over 57,000 Bq/m 3 was discovered in a populated community “Agua de Venados” during the 2009–2011 soil Radon survey in San Joaquin, Queretaro State, Mexico. The indoor Radon monitoring accomplished in 2 different époques in a nearby 4 dwellings has shown an increased Radon hazard in 1 of the 4 buildings (about 300 Bq/m 3 ) during a rainy season and highly elevated indoor Radon levels (over 400 Bq/m 3 ) already in 3 buildings during a dry season. The averaged diurnal indoor Radon variations are in a correlation with the atmospheric pressure and the air humidity and are independent on the air temperature. The maximum indoor Radon hazard for dwellings is estimated for the morning interval 5–10 a.m. - Highlights: ► Emanative zone of 57,000 Bq/m 3 was found in area “Agua de Venados”. ► Indoor Radon level in a nearby dwellings elevates during a dry season. ► Maximum risk for residents was estimated during the daily interval 5–10 a.m

  17. Evolution of the indoor biome.

    Science.gov (United States)

    Martin, Laura J; Adams, Rachel I; Bateman, Ashley; Bik, Holly M; Hawks, John; Hird, Sarah M; Hughes, David; Kembel, Steven W; Kinney, Kerry; Kolokotronis, Sergios-Orestis; Levy, Gabriel; McClain, Craig; Meadow, James F; Medina, Raul F; Mhuireach, Gwynne; Moreau, Corrie S; Munshi-South, Jason; Nichols, Lauren M; Palmer, Clare; Popova, Laura; Schal, Coby; Täubel, Martin; Trautwein, Michelle; Ugalde, Juan A; Dunn, Robert R

    2015-04-01

    Few biologists have studied the evolutionary processes at work in indoor environments. Yet indoor environments comprise approximately 0.5% of ice-free land area--an area as large as the subtropical coniferous forest biome. Here we review the emerging subfield of 'indoor biome' studies. After defining the indoor biome and tracing its deep history, we discuss some of its evolutionary dimensions. We restrict our examples to the species found in human houses--a subset of the environments constituting the indoor biome--and offer preliminary hypotheses to advance the study of indoor evolution. Studies of the indoor biome are situated at the intersection of evolutionary ecology, anthropology, architecture, and human ecology and are well suited for citizen science projects, public outreach, and large-scale international collaborations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Indoor air: Reference bibliography

    International Nuclear Information System (INIS)

    Campbell, D.; Staves, D.; McDonald, S.

    1989-07-01

    The U. S. Environmental Protection Agency initially established the indoor air Reference Bibliography in 1987 as an appendix to the Indoor Air Quality Implementation Plan. The document was submitted to Congress as required under Title IV--Radon Gas and Indoor Air Quality Research of the Superfund Amendments and Reauthorization Act of 1986. The Reference Bibliography is an extensive bibliography of reference materials on indoor air pollution. The Bibliography contains over 4500 citations and continues to increase as new articles appear

  19. Synthesis and characterization of nanostructured iron compounds prepared from the decomposition of iron pentacarbonyl dispersed into carbon materials with varying porosities

    International Nuclear Information System (INIS)

    Schettino, Miguel A. Jr.; Cunha, Alfredo G.; Nunes, Evaristo; Passamani, Edson C.; Freitas, Jair C. C.; Emmerich, Francisco G.; Morigaki, Milton K.

    2016-01-01

    This work describes the production and characterization of carbon-iron nanocomposites obtained from the decomposition of iron pentacarbonyl (Fe(CO) 5 ) mixed with different carbon materials: a high surface area activated carbon (AC), powdered graphite (G), milled graphite (MG), and carbon black (CB). The nanocomposites were prepared either under argon or in ambient atmosphere, with a fixed ratio of Fe(CO) 5 (4.0 mL) to carbon precursor (2.0 g). The images of scanning electron microscopy and the analysis of textural properties indicated the presence of nanostructured Fe compounds homogeneously dispersed into the different classes of pores of the carbon matrices. The elemental Fe content was always larger for samples prepared in ambient atmosphere, reaching values in the range of 20–32 wt%. On the other hand, samples prepared under argon showed reduced Fe content, with values in the range 5–10 wt% for samples prepared from precursors with low surface area (G, MG, and CB) and a much higher value (~19 wt%) for samples prepared from the precursor of high surface area (AC). Mössbauer spectroscopy and X-ray diffractometry showed that the nanoparticles were mostly composed of iron oxides in the case of the samples prepared in oxygen-rich ambient atmosphere and also for the AC-derived nanocomposite prepared under argon, which is consistent with the large oxygen content of this precursor. For the other precursors, with reduced or no oxygen content, metallic iron and iron carbides were found to be the dominant phases in samples prepared under oxygen-free atmosphere. The samples prepared in ambient atmosphere and the AC-derived sample prepared under argon exhibited superparamagnetic behavior at room temperature, as revealed by temperature-dependent magnetization curves and Mössbauer spectroscopy.

  20. Indoor climate design for a monumental building with incidental high indoor moisture loads

    NARCIS (Netherlands)

    Schijndel, van A.W.M.

    2005-01-01

    The paper presents a study of the indoor climate of a monumental building with periodic high indoor moisture loads. Several scenarios of the past performance and new control classes are simulated and evaluated. The results include the influence of hygric inertia on the indoor climate and

  1. Indoor air quality in urban and rural kindergartens: short-term studies in Silesia, Poland.

    Science.gov (United States)

    Błaszczyk, Ewa; Rogula-Kozłowska, Wioletta; Klejnowski, Krzysztof; Kubiesa, Piotr; Fulara, Izabela; Mielżyńska-Švach, Danuta

    2017-01-01

    More than 80% of people living in urban areas who monitor air pollution are exposed to air quality levels that exceed limits defined by the World Health Organization (WHO). Although all regions of the world are affected, populations in low-income cities are the most impacted. According to average annual levels of fine particulate matter (PM2.5, ambient particles with aerodynamic diameter of 2.5 μm or less) presented in the urban air quality database issued by WHO in 2016, as many as 33 Polish cities are among the 50 most polluted cities in the European Union (EU), with Silesian cities topping the list. The aim of this study was to characterize the indoor air quality in Silesian kindergartens based on the concentrations of gaseous compounds (SO 2 , NO 2 ), PM2.5, and the sum of 15 PM2.5-bound polycyclic aromatic hydrocarbons (PAHs), including PM2.5-bound benzo(a)pyrene (BaP), as well as the mutagenic activity of PM2.5 organic extracts in Salmonella assay (strains: TA98, YG1024). The assessment of the indoor air quality was performed taking into consideration the pollution of the atmospheric air (outdoor). I/O ratios (indoor/outdoor concentration) for each investigated parameter were also calculated. Twenty-four-hour samples of PM2.5, SO 2 , and NO 2 were collected during spring in two sites in southern Poland (Silesia), representing urban and rural areas. Indoor samples were taken in naturally ventilated kindergartens. At the same time, in the vicinity of the kindergarten buildings, the collection of outdoor samples of PM2.5, SO 2 , and NO 2 was carried out. The content of BaP and the sum of 15 studied PAHs was determined in each 24-h sample of PM2.5 (indoor and outdoor). In the urban site, statistically lower concentrations of SO 2 and NO 2 were detected indoors compared to outdoors, whereas in the rural site, such a relationship was observed only for NO 2 . No statistically significant differences in the concentrations of PM2.5, PM2.5-bound BaP, and Σ15 PAHs

  2. Indoor deposition and the protective effect of houses against airborne pollution

    International Nuclear Information System (INIS)

    Lang, C.

    1995-05-01

    The protective value of a house during a release of toxic materials has been investigated to the atmosphere. A review of the relevant literature revealed wide agreement on dose reduction factors from 0.5 to 0.2. According to the literature indoor deposition rather than filtration by the building envelope was the main cause of the reduction, but very little information on indoor deposition exists. The main topic for this work has been the measurement of indoor deposition using monodisperse particles in the size range 0.5 to 5.5 μm, labelled with neutron activable tracers. The decay of aerosol concentration was measured and average deposition velocities were recorded in four houses. The results were consistent with increasing deposition velocities for increasing particle size and increasing degree of furnishing. Neutron activable particles have been used for measurements of skin deposition velocities to a human volunteer. The deposition velocity was found to be 7.4±1.1 x 10 -4 ms -+ for the 0.5 μm particles and 57 + - 1 4 x 10 -4 ms -1 for the 2.5 m u m particles values of skin deposition velocities imply that the amount of pollutants deposited to the skin of a dressed person is more than an order of magnitude larger than the amount deposited in the lungs, and that skin deposition is an important pathway for toxics that can penetrate through the skin. Beryllium-7 was used as a tracer in a series of experiments. The activity distribution of this isotope was determined using a Berne low pressure impactor. Median diameters ranged from 0.7 to 1.1 μm and it was found that the activity distribution followed the mass distribution of the accumulation mode for atmospheric particles. I/O measurements have been made with two impactors. The results showed that the reduction in indoor air concentration was largest for supra micron particles. (au) 26 tabs., 46 ills., 87 refs

  3. Indoor deposition and the protective effect of houses against airborne pollution

    Energy Technology Data Exchange (ETDEWEB)

    Lang, C

    1995-05-01

    The protective value of a house during a release of toxic materials has been investigated to the atmosphere. A review of the relevant literature revealed wide agreement on dose reduction factors from 0.5 to 0.2. According to the literature indoor deposition rather than filtration by the building envelope was the main cause of the reduction, but very little information on indoor deposition exists. The main topic for this work has been the measurement of indoor deposition using monodisperse particles in the size range 0.5 to 5.5 {mu}m, labelled with neutron activable tracers. The decay of aerosol concentration was measured and average deposition velocities were recorded in four houses. The results were consistent with increasing deposition velocities for increasing particle size and increasing degree of furnishing. Neutron activable particles have been used for measurements of skin deposition velocities to a human volunteer. The deposition velocity was found to be 7.4{+-}1.1 x 10{sup -4} ms{sup -+} for the 0.5 {mu}m particles and 57{sup +}-{sup 1}4 x 10{sup -4} ms{sup -1} for the 2.5 {sup m}u{sup m} particles values of skin deposition velocities imply that the amount of pollutants deposited to the skin of a dressed person is more than an order of magnitude larger than the amount deposited in the lungs, and that skin deposition is an important pathway for toxics that can penetrate through the skin. Beryllium-7 was used as a tracer in a series of experiments. The activity distribution of this isotope was determined using a Berne low pressure impactor. Median diameters ranged from 0.7 to 1.1 {mu}m and it was found that the activity distribution followed the mass distribution of the accumulation mode for atmospheric particles. I/O measurements have been made with two impactors. The results showed that the reduction in indoor air concentration was largest for supra micron particles. (au) 26 tabs., 46 ills., 87 refs.

  4. Application Of Fractal Dimension On Atmospheric Corrosion Of Galvanized Iron Roofing Material

    Directory of Open Access Journals (Sweden)

    Issa A.K

    2015-08-01

    Full Text Available Abstract Corrosion rates of galvanized iron roofing sheet In yola north eastern part of Nigeria were assessed and determined by weight loss method and scanner fractal analysis method. Scanning electronic machine SEM was used to transform corrosion coupons to electronic form for image j processing and analysing software The result of corrosion rates for these two methods after six months of the samples exposure in industrial. Coastal market and urban areas in the region are 1.51 1.079 1.051 0.779 and 1.9941 1.9585 1.9565 1.9059 for weight loss and scanner fractal dimension methods respectively. and the results from the two methods were in agreement This establish the reliability of fractal dimension in measuring atmospheric corrosion this research also provides alternative method of measuring atmospheric corrosion and overcome the limitation of conventional weight loss technique in its inability to measure corrosion rate which is not significantly change over a long period of time moreover weight loss cannot demonstrate the area of concentration of corrosion on the surface of the coupon it rather gives the weight loss value and this will aid in determining the real level or extent of corrosion damage in the material and this can be obtained when measuring the material through fractal analysis these results clearly indicate that corrosion is heavier on locations close to the industrial areas. This also shows the negative impact of industrial activities on the corrodible materials and consequently on the plants and environment.

  5. Current Indoor Air Quality in Japan.

    Science.gov (United States)

    Jinno, Hideto

    2016-01-01

    People spend more than two thirds of their daily time indoors. Hence, maintaining a healthy indoor environment is indispensable for the prevention of building related illness. In Japan, guidelines for indoor air quality have been established for 13 volatile/semi-volatile organic compounds (VOCs/SVOCs). These guidelines are now under revision by the Committee on Sick House Syndrome: Indoor Air Pollution. In order to gain information on the current indoor air pollutants and their levels, we carried out a nation-wide survey of VOCs and aldehydes in indoor residential air during 2012-2013. In this review, I concisely summarized the current indoor air quality of Japan.

  6. Indoor air pollution

    International Nuclear Information System (INIS)

    Anwar, J.; Hussain, F.

    2005-01-01

    Indoor air pollution after being a neglected subject for a number of years, is attracting attention recently because it is a side effect of energy crisis. About 50% of world's 6 billion population, mostly in developing countries, depend on biomass and coal in the form of wood, dung and crop residues for domestic energy because of poverty. These materials are burnt in simple stoves with incomplete combustion and infants, children and women are exposed to high levels of indoor air pollution for a considerable period, approximately between 2-4 hours daily. Current worldwide trade in wood fuel is over US $7 billion and about 2 million people are employed full time in production and marketing it. One of the most annoying and common indoor pollutant in both, developing and developed countries, is cigarette smoke. Children in gas-equipped homes had higher incidences of respiratory disease. Babies' DNA can be damaged even before they are born if their mothers breathe polluted air. Exposure to indoor air pollution may be responsible for nearly 2 million excess deaths in developing countries and for 4% of the global burden of the disease. Only a few indoor pollutants have been studied in detail. Indoor air pollution is a major health threat on which further research is needed to define the extent of the problem more precisely and to determine solutions by the policy-makers instead of neglecting it because sufferers mostly belong to Third World countries. (author)

  7. The measurement of 222Rn and its relationship to environmental variables: Factors controlling indoor radon: Final report for the contract period June 1, 1982 to May 31, 1985

    International Nuclear Information System (INIS)

    Harley, N.H.

    1985-01-01

    Indoor levels of radon-222 and daughter nuclei were monitored at various locations within a single family dwelling and in an apartment building. Indoor levels were correlated with soil temperature, atmospheric pressure, wind, rain and time of year. 9 refs., 23 figs., 19 tabs

  8. Number Concentrations and Modal Structure of Indoor/Outdoor Fine Particles in Four European Cities.

    Czech Academy of Sciences Publication Activity Database

    Lazaridis, M.; Eleftheriadis, K.; Ždímal, Vladimír; Schwarz, Jaroslav; Wagner, Zdeněk; Ondráček, Jakub; Drossinos, Y.; Glytsos, T.; Vratolis, S.; Torseth, K.; Moravec, Pavel; Hussein, T.; Smolík, Jiří

    2017-01-01

    Roč. 17, č. 1 (2017), s. 131-146 ISSN 1680-8584 EU Projects: European Commission(XE) 315760 - HEXACOMM Institutional support: RVO:67985858 Keywords : indoor/outdoor aerosol * I/O ratio * modal structure Subject RIV: DG - Athmosphere Sciences, Meteorology OBOR OECD: Meteorology and atmospheric sciences Impact factor: 2.606, year: 2016

  9. Atmospheric sciences annual progress report, 1974

    International Nuclear Information System (INIS)

    Tucker, W.D.

    1975-11-01

    Activities in atmospheric sciences in the Department of Applied Science at Brookhaven National Laboratory carried out during 1974 are described. Included are contributions from the Meteorology, Atmospheric Diagnostics, Atmospheric Chemistry Research, and Atmospheric Instrumentation Groups. Programs in Meteorology reported on include diffusion from an off-shore source, plume dynamics studies, modeling of coastal effects on wind and temperature fields and pollutant distributions, effects of indoor shelter on inhalation of airborne radionuclides, chemical-dynamical interactions, techniques for determining acid-rain impact upon the ecology of the eastern U.S., and climatology. Work under Atmospheric Chemistry Research was concentrated on atmospheric aerosol studies, including formation by free radical and neutral association reactions, identification of reactive systems leading to aerosol formation, growth of sodium aerosols under atmospheric conditions and clustering reactions. Atmospheric Diagnostics presents work on field sampling and analytical technology for atmospheric pollutants, airborne sampling systems, atmospheric sulfate particulates methodology, and on a pyroturbidometric method for particulate sulfate discrimination and determination. Methodology for the use of sulfur hexafluoride in field tracer studies is discussed under Atmospheric Instrumentation. A list of publications is included

  10. THE ASSESSMENT OF MICROBIOLOGICAL INDOOR AIR QUALITY IN BAKERIES

    Directory of Open Access Journals (Sweden)

    Elżbieta Wołejko

    2016-05-01

    Full Text Available The aim of this study was to assess microbiological indoor air quality of selected bakeries located in the region of Podlasie. The microbiological studies were conducted in autumn in 2014 in three selected bakeries. Microbiological air counts were measured by impaction using an air sampler MAS-100 NT. The microbiological air studies, comprised the determination of the total number of psychrophilic and mesophilic bacteria, namely indicator bacteria such as: bacteria of the species Pseudomonas fluorescens, mannitol-positive and mannitol-negative Staphylococc, the total number of bacteria from the Enterobacteriaceae family and fungi found in atmospheric air. The results of the study of indoor air polluted with the analyzed groups of microorganisms differed depending on the type of test air and the location of the manufacturing plant. In the plants, the concentration of mesophilic bacteria and mannitol–positive and mannitol-negative Staphylococcus exceeded the limit values of unpolluted air, according to the Polish Standard recommendations.

  11. Indoor air quality: The hidden side of the indoor environment

    NARCIS (Netherlands)

    Oliveira Fernandes, E. de; Bluyssen, P.M.; Clausen, G.H.

    1996-01-01

    The physical environment can be defined and understood in manv different ways, both from its nature, e.g., thermal, accoustic, etc., or its dimension, e.g., global, local, urban, indoors. The indoor environment is much more than the space or the light effects; it is the result of a complex

  12. AN ALTERNATIVE HOST MATRIX BASED ON IRON PHOSPHATE GLASSES FOR THE VITRIFICATION OF SPECIALIZED WASTE FORMS

    International Nuclear Information System (INIS)

    Day, Delbert D.

    2000-01-01

    As mentioned above, the overall goal of this research project was to collect the scientific information essential to develop iron phosphate glass based nuclear wasteforms. The specific objectives of the project were: (1) Investigate the structure of binary iron phosphate glasses and it's dependence on the composition and melting atmosphere: Understand atomic arrangements and nature of the bonding. Establish structure-property relationships. Determine the compositions and melting conditions which optimize the critical properties of the base glass. (2) Understand the structure of iron phosphate wasteforms and it's dependence on the composition and melting atmosphere: Investigate how the waste elements are bonded and coordinated within the glass structure. Establish structure-property relationships for the waste glasses. Determine the compositions and melting atmosphere for which the critical properties of the waste forms would be optimum. (3) Determine the role(s) played by the valence states of iron ions and it's dependence on the composition and melting atmosphere: Understand the different roles of iron(II) and iron(III) ions in determining the critical properties of the base glass and the waste forms. Investigate how the iron valence and its significance depend on the composition and melting atmosphere. (4) Investigate glass forming and crystallization processes of the iron phosphate glasses and their waste forms: Understand the dependence of the glass forming and crystallization characteristics on overall glass composition and valence states of iron ions. Identify the products of devitrification and investigate the critical properties of these crystalline compounds which may adversely affect the chemical and physical properties of the waste forms

  13. Characterization of radon entry rates and indoor concentrations in underground structures

    International Nuclear Information System (INIS)

    Borak, T.B.; Whicker, F.W.; Fraley, L.; Gadd, M.S.; Ibrahim, S.A.; Monette, F.A.; Morris, R.; Ward, D.C.

    1992-01-01

    An experimental facility has been designed to comprehensively determine the influence of soil and meterological conditions on the transport of radon into underground structures. Two identical basements are equipped to continuously monitor pressure differentials, temperatures, soil moisture, precipitation, barometric pressure, wind speed, wind direction, natural ventiliation rates, and radon concentrations. A computerized data acquisition system accumulates and processes data at the rate of 6000 points per day. The experimental design is based on performing experiments in one structure, with the other used as a control. Indoor radon concentrations have temporal variations ranging from 150 to 1400 Bq m -3 . The corresponding entry rate of radon ranges from 300 to 10,000 Bq h -1 . When the radon entry rate is high, the indoor radon concentration decreases, whereas elevated radon concentrations seem to be associated with slow but persistent radon entry rates. This inverse relationship is partially due to compensation from enhanced natural ventilation during periods when the radon entry rate is high. Correlations between measured variables in the soil and indoor-outdoor atmospheres are used to interpret these data. This laboratory has the capability to generate essential data required for developing and testing radon transport models

  14. Preliminary assessment of BTEX concentrations in indoor air of residential buildings and atmospheric ambient air in Ardabil, Iran

    Science.gov (United States)

    Hazrati, Sadegh; Rostami, Roohollah; Farjaminezhad, Manoochehr; Fazlzadeh, Mehdi

    2016-05-01

    BTEX concentrations in indoor and outdoor air of 50 homes were studied in Ardabil city and their influencing parameters including; heating system, using gas stove and samovar, tobacco smoking, the floors in which the monitored homes were located, and kitchen plan were considered in the study. Risk assessment analysis was carried out with the obtained concentrations based on EPA IRIS reference doses. BTEX compounds were sampled by charcoal tubes and the samples were analyzed by a GC-FID. Concentrations of benzene (15.18 μg/m3 vs. 8.65 μg/m3), toluene (69.70 μg/m3 vs. 40.56 μg/m3), ethylbenzene (12.07 μg/m3 vs. 4.92 μg/m3) and xylene (48.08 μg/m3 vs. 7.44 μg/m3) in indoor air were significantly (p < 0.05) higher than the levels quantified for outdoor air. The obtained concentrations of benzene were considerably higher than the recommended value of 5 μg/m3 established by Iran environmental protection organization. Among the BTEX compounds, benzene (HQ = 0.51) and xylene (HQ = 0.47) had notable hazard quotient and were the main pollutants responsible for high hazard index in the monitored homes (HI = 1.003). The results showed considerably high cancer risk for lifetime exposure to the indoor (125 × 10-6) and outdoor (71 × 10-6) benzene. Indoor benzene concentrations in homes were significantly influenced by type of heating system, story, and natural gas appliances.

  15. A comprehensive air quality investigation at an aquatic centre: Indoor/outdoor comparisons.

    Science.gov (United States)

    Tolis, Evangelos I; Panaras, Giorgos; Bartzis, John G

    2018-06-01

    Air quality and comfort parameters in a naturally ventilated aquatic centre were studied in relation to the outdoor pollution levels. Simultaneous measurements of PM 2.5, as well as of volatile organic compounds, were carried out for the indoor and outdoor environment of the aquatic centre. The chemical analysis of ionic species and trace elements associated with particulate matter was also performed. In addition, automated analyzer for NO 2 and O 3 was used in order to record the indoor and outdoor levels of these pollutants. Analysis of diurnal variation of the pollutants' concentration was applied to the collected data, allowing the identification of potential variation on the sources affecting the indoor air quality. PM 2.5 concentration was almost two times higher indoors than outdoors with average values of 13.96 and 6.78 μg/m 3 , respectively. Concerning the ion fraction of PM 2.5, SO 4 2- and Ca 2+ were the ions with higher concentration indoors with values of 1.06 and 0.93 μg/m 3 , respectively, while the percentage of Cl - to the PM 2.5 fraction of the indoor atmosphere (9%) was too high than outdoor ones (1%). These results showed that indoor air of swimming pool concerning PM 2.5 and ionic species is mainly affected by the chlorination process along with the comfort conditions (high relative humidity) created during the operation of the facility. The common volatile organic compound concentrations at indoor air are generally in higher levels, compared to the outdoor air with p,m-xylene and toluene to be the substances with the higher concentration for indoor and outdoor area, respectively (7.80 and 1.57 μg/m 3 ); nevertheless, values were rather low compared with the findings of other studies. Also, they clearly demonstrate a diurnal variation as a result of poor ventilation during night. As it was expected, chloroform showed the highest concentration compared to the other volatile organic compounds with values ranging from 3.35 to 135.89 μg/m 3

  16. Polluted air--outdoors and indoors.

    Science.gov (United States)

    Myers, I; Maynard, R L

    2005-09-01

    Many air pollutants which are considered important in ambient (outdoor) air are also found, sometimes at higher levels, in indoor air. With demanding standards having been set for many of these pollutants, both in the workplace and ambient air, consideration of the problems posed by indoor pollution is gaining pace. Studies on exposure to pollutants found in the indoor domestic environment are increasing and are contributing to an already significant compilation of datasets. Improvement in monitoring techniques has helped this process. Documented reports of fatalities from carbon monoxide poisonings are still worrying. However, studies on health effects of non-fatal, long term, low dose, indoor exposure to carbon monoxide and other pollutants, are still inconclusive and too infrequently documented. Of particular concern are the levels of air pollutants found in the domestic indoor environment in developing countries, despite simple interventions such as vented stoves having shown their value. Exposure to biomass smoke is still a level that would be considered unacceptable on health grounds in developed countries. As in the occupational environment, steps need to be taken to control the risks from exposure to the harmful constituents of indoor air in the home. However, the difficulty regarding regulation of the domestic indoor environment is its inherent privacy. Monitoring levels of pollutants in the home and ensuring regulations are adhered to, would likely prove difficult, especially when individual behaviour patterns and activities have the greatest influence on pollutant levels in indoor air. To this end, the Department of Health is developing guidance on indoor air pollution to encourage the reduction of pollutant levels in indoor domestic air. The importance of the effects of domestic indoor air on health and its contribution to the health of the worker are increasingly appreciated. Occupational physicians, by training and interest, are well placed to extend

  17. Indoor navigation by image recognition

    Science.gov (United States)

    Choi, Io Teng; Leong, Chi Chong; Hong, Ka Wo; Pun, Chi-Man

    2017-07-01

    With the progress of smartphones hardware, it is simple on smartphone using image recognition technique such as face detection. In addition, indoor navigation system development is much slower than outdoor navigation system. Hence, this research proves a usage of image recognition technique for navigation in indoor environment. In this paper, we introduced an indoor navigation application that uses the indoor environment features to locate user's location and a route calculating algorithm to generate an appropriate path for user. The application is implemented on Android smartphone rather than iPhone. Yet, the application design can also be applied on iOS because the design is implemented without using special features only for Android. We found that digital navigation system provides better and clearer location information than paper map. Also, the indoor environment is ideal for Image recognition processing. Hence, the results motivate us to design an indoor navigation system using image recognition.

  18. Change of iron species and iron solubility in Asian dust during the long-range transport from western China to Japan

    Directory of Open Access Journals (Sweden)

    Y. Takahashi

    2011-11-01

    Full Text Available In the North Pacific, transport and deposition of mineral dust from Asia appear to be one of major sources of iron which can regulate growth of phytoplankton in the ocean. In this process, it is essential to identify chemical species of iron contained in Asian dust, because bioavailability of iron in the ocean is strongly influenced by the solubility of iron, which in turn is dependent on iron species in the dust. Here, we report that clay minerals (illite and chlorite in the dusts near the source collected at Aksu (western China can be transformed into ferrihydrite by atmospheric chemical processes during their long-range transport to eastern China (Qingdao and Japan (Tsukuba based on the speciation by X-ray absorption fine structure (XAFS and other methods such as X-ray diffraction and chemical extraction. As a result, Fe molar ratio in Aksu (illite : chlorite : ferrihydrite = 70 : 25 : 5 was changed to that in Tsukuba (illite : chlorite : ferrihydrite = 65 : 10 : 25. Moreover, leaching experiments were conducted to study the change of iron solubility. It was found that the iron solubility for the dust in Tsukuba (soluble iron fraction: 11.8 % and 1.10 % for synthetic rain water and seawater, respectively was larger than that in Aksu (4.1 % and 0.28 %, respectively, showing that iron in the dust after the transport becomes more soluble possibly due to the formation of ferrihydrite in the atmosphere. Our findings suggested that secondary formation of ferrihydrite during the transport should be considered as one of important processes in evaluating the supply of soluble iron to seawater.

  19. Indoor air quality

    International Nuclear Information System (INIS)

    Hollowell, C.D.

    1981-06-01

    Rising energy prices, among other factors, have generated an incentive to reduce ventilation rates and thereby reduce the cost of heating and cooling buildings. Reduced ventilation in buildings may significantly increase exposure to indoor air pollution and perhaps have adverse effects on occupant health and comfort. Preliminary findings suggest that reduced ventilation may adversely affect indoor air quality unless appropriate control strategies are undertaken. The strategies used to control indoor air pollution depend on the specific pollutant or class of pollutants encountered, and differ somewhat depending on whether the application is to an existing building or a new building under design and construction. Whenever possible, the first course of action is prevention or reduction of pollutant emissions at the source. In most buildings, control measures involve a combination of prevention, removal, and suppression. Common sources of indoor air pollution in buildings, the specific pollutants emitted by each source, the potential health effects, and possible control techniques are discussed

  20. Atmospheric pollution. From processes to modelling

    International Nuclear Information System (INIS)

    Sportisse, B.

    2008-01-01

    Air quality, greenhouse effect, ozone hole, chemical or nuclear accidents.. All these phenomena are tightly linked to the chemical composition of atmosphere and to the atmospheric dispersion of pollutants. This book aims at supplying the main elements of understanding of 'atmospheric pollutions': stakes, physical processes involved, role of scientific expertise in decision making. Content: 1 - classifications and scales: chemical composition of the atmosphere, vertical structure, time scales (transport, residence); 2 - matter/light interaction: notions of radiative transfer, application to the Earth's atmosphere; 3 - some elements about the atmospheric boundary layer: notion of scales in meteorology, atmospheric boundary layer (ABL), thermal stratification and stability, description of ABL turbulence, elements of atmospheric dynamics, some elements about the urban climate; 4 - notions of atmospheric chemistry: characteristics, ozone stratospheric chemistry, ozone tropospheric chemistry, brief introduction to indoor air quality; 5 - aerosols, clouds and rains: aerosols and particulates, aerosols and clouds, acid rains and leaching; 6 - towards numerical simulation: equation of reactive dispersion, numerical methods for chemistry-transport models, numerical resolution of the general equation of aerosols dynamics (GDE), modern simulation chains, perspectives. (J.S.)

  1. The influence of atmospheric pollutants on the deterioration of museum collections

    International Nuclear Information System (INIS)

    Injuk, J.; Van Grieken, R.

    2001-01-01

    In view of the above issues, the purpose of our research effort was to establish the ranges of chemical composition, concentration, size distribution and sources of the airborne particulate matter found in the indoor atmosphere of several European and one Japanese museum. The chemical composition, size and indoor and outdoor origin of the suspended particulate matter have been identified with a number of X-ray techniques such as electron Probe X-Ray microanalysis (EPXMA) and energy Dispersive X-ray Fluorescence Analysis. Our results constitute to our knowledge the first detailed study of the chemical nature of the indoor particulate matter in the selected museums and to the lasting conservation of the works of art

  2. Characterization of iron speciation in urban and rural single particles using XANES spectroscopy and micro X-ray fluorescence measurements: investigating the relationship between speciation and fractional iron solubility

    OpenAIRE

    Oakes, M.; Weber, R. J.; Lai, B.; Russell, A.; Ingall, E. D.

    2012-01-01

    Soluble iron in fine atmospheric particles has been identified as a public health concern by participating in reactions that generate reactive oxygen species (ROS). The mineralogy and oxidation state (speciation) of iron have been shown to influence fractional iron solubility (soluble iron/total iron). In this study, iron speciation was determined in single particles at urban and rural sites in Georgia USA using synchrotron-based techniques, such as X-ray Absorption Near-Edge Structure (XANES...

  3. Spatial subdivision of complex indoor environments for 3D indoor navigation

    NARCIS (Netherlands)

    Diakite, A.A.; Zlatanova, S.

    2018-01-01

    As we realize that we spend most of our time in increasingly complex indoor environments, applications to assist indoor activities (e.g. guidance) have gained a lot of attention in the recent years. The advances in ubiquitous computing made possible the development of several spatial models

  4. Graph Model Based Indoor Tracking

    DEFF Research Database (Denmark)

    Jensen, Christian Søndergaard; Lu, Hua; Yang, Bin

    2009-01-01

    The tracking of the locations of moving objects in large indoor spaces is important, as it enables a range of applications related to, e.g., security and indoor navigation and guidance. This paper presents a graph model based approach to indoor tracking that offers a uniform data management...

  5. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments

    Energy Technology Data Exchange (ETDEWEB)

    Stojanovska, Zdenka; Janevik, Emilija; Taleski, Vaso [Goce Delcev University, Faculty of Medical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Boev, Blazo [Goce Delcev University, Faculty of Natural and Technical Sciences, Stip (Macedonia, The Former Yugoslav Republic of); Zunic, Zora S. [University of Belgrade, Institute of Nuclear Sciences ' ' Vinca' ' , Belgrade (Serbia); Ivanova, Kremena; Tsenova, Martina [National Center of Radiobiology and Radiation Protection, Sofia (Bulgaria); Ristova, Mimoza [University in Ss. Cyril and Methodius, Faculty of Natural Sciences and Mathematic, Institute of Physics, Skopje (Macedonia, The Former Yugoslav Republic of); Ajka, Sorsa [Croatian Geological Survey, Zagreb (Croatia); Bossew, Peter [German Federal Office for Radiation Protection, Berlin (Germany)

    2016-05-15

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m{sup 3} for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported. (orig.)

  6. Spatial and indoor/outdoor gradients in urban concentrations of ultrafine particles and PM2.5 mass and chemical components

    Science.gov (United States)

    Zauli Sajani, Stefano; Ricciardelli, Isabella; Trentini, Arianna; Bacco, Dimitri; Maccone, Claudio; Castellazzi, Silvia; Lauriola, Paolo; Poluzzi, Vanes; Harrison, Roy M.

    2015-02-01

    In order to investigate relationships between outdoor air pollution and concentrations indoors, a novel design of experiment has been conducted at two sites, one heavily trafficked and the other residential. The novel design aspect involves the introduction of air directly to the centre of an unoccupied room by use of a fan and duct giving a controlled air exchange rate and allowing an evaluation of particle losses purely due to uptake on indoor surfaces without the losses during penetration of the building envelope which affect most measurement programmes. The rooms were unoccupied and free of indoor sources, and consequently reductions in particle concentration were due to deposition processes within the room alone. Measurements were made of indoor and outdoor concentrations of PM2.5, major chemical components and particle number size distributions. Despite the absence of penetration losses, indoor to outdoor ratios were very similar to those in other studies showing that deposition to indoor surfaces is likely to be the major loss process for indoor air. The results demonstrated a dramatic loss of nitrate in the indoor atmosphere as well as a selective loss of particles in the size range below 50 nm, in comparison to coarser particles. Depletion of indoor particles was greater during a period of cold weather with higher outdoor concentrations probably due to an enhancement of semi-volatile materials in the outdoor particulate matter. Indoor/outdoor ratios for PM2.5 were generally higher at the trafficked site than the residential site, but for particle number were generally lower, reflecting the different chemical composition and size distributions of particles at the two sites.

  7. Indoor microclimate in a South African school: impact of indoor environmental factors

    CSIR Research Space (South Africa)

    Essah, EA

    2016-07-01

    Full Text Available Demand for good indoor air quality is increasing as people recorgnise the risks to their health and productivity from indoor pollutants. There is a tendency to reduce ventilation rates to ensure energy conservation in buildings; in this instance...

  8. Effectiveness of Indoor Plant to Reduce CO2 in Indoor Environment

    Directory of Open Access Journals (Sweden)

    Suhaimi Mohd Mahathir

    2017-01-01

    Full Text Available Modern country strongly emphasizes on indoor air quality (IAQ because it can effect on human health and productivity. Numerous efforts were performed to make sure that sustainability of IAQ is guaranteed. In the last 4th decade, researchers discover that indoor plants have abilities to reduce indoor air pollution. Generally, plants, carbon dioxide (CO2, light, and temperature involve in the photosynthesis process. This paper intends to study the effectiveness of seven indoor plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium to reduce CO2 with different light level. This study was conducted in one cubic meter of chamber, and each plant was put into the chamber individually with CO2 concentration in the chamber is set at 1000±50ppm, and light intensities is set at 300 and 700 lux, while temperature were fixed at 25±1°C. Based on the results, only the Spider Plant was not able to absorb CO2 during the test at 300 lux of light intensity. Meanwhile, Prayer Plant performed well when tested at 300 or 700 lux of light intensity compare to other investigates plants. This study can conclude that light intensity play an important role for the plant to absorb CO2 effectively. All the indoor plants absorbed more CO2, when the light intensity is increased.

  9. Measurement of indoor and outdoor radon concentrations during Superstorm Sandy.

    Science.gov (United States)

    Kotrappa, Payasada; Paul, Prateek; Stieff, Alex; Stieff, Frederick

    2013-12-01

    Superstorm Sandy affected much of the US East Coast extending over 1800 km. It passed over the test location in the State of Maryland on 29 October 2012. Being 350 km away from the regions of highest intensity the storm was of lower intensity at the test location. Continuous radon monitors and passive radon monitors were used for the measurement. The test location was the basement of a single family home representing the indoor concentration. A partially opened garage of the same test home represented the outdoor radon concentration. In 24 h, the atmospheric pressure dropped from 990 to 960 mbar and the indoor radon concentration increased from 70 to 1500 Bq m(-3) and returned to the normal of 70 Bq m(-3) at the end of the storm. Throughout the storm, the outdoor radon concentration was not significantly affected. Probable reasons for such surprisingly large changes are discussed. However, the outdoor temperature dropped from 13°C to 7°C during the radon peak.

  10. The lasting effect of limonene-induced particle formation on air quality in a genuine indoor environment.

    Science.gov (United States)

    Rösch, Carolin; Wissenbach, Dirk K; von Bergen, Martin; Franck, Ulrich; Wendisch, Manfred; Schlink, Uwe

    2015-09-01

    Atmospheric ozone-terpene reactions, which form secondary organic aerosol (SOA) particles, can affect indoor air quality when outdoor air mixes with indoor air during ventilation. This study, conducted in Leipzig, Germany, focused on limonene-induced particle formation in a genuine indoor environment (24 m(3)). Particle number, limonene and ozone concentrations were monitored during the whole experimental period. After manual ventilation for 30 min, during which indoor ozone levels reached up to 22.7 ppb, limonene was introduced into the room at concentrations of approximately 180 to 250 μg m(-3). We observed strong particle formation and growth within a diameter range of 9 to 50 nm under real-room conditions. Larger particles with diameters above 100 nm were less affected by limonene introduction. The total particle number concentrations (TPNCs) after limonene introduction clearly exceed outdoor values by a factor of 4.5 to 41 reaching maximum concentrations of up to 267,000 particles cm(-3). The formation strength was influenced by background particles, which attenuated the formation of new SOA with increasing concentration, and by ozone levels, an increase of which by 10 ppb will result in a six times higher TPNC. This study emphasizes indoor environments to be preferred locations for particle formation and growth after ventilation events. As a consequence, SOA formation can produce significantly higher amounts of particles than transported by ventilation into the indoor air.

  11. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull 2007; 6(3.000: 221-226

  12. INDOOR AIR POLLUTION

    Directory of Open Access Journals (Sweden)

    Ahmet Soysal

    2007-06-01

    Full Text Available The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas and people in the cities have spending approximetely 90% of their time in the closed enviroments, health problems could increased due to indoor air pollution. Moreover, currently there is no specific regulation on this area. [TAF Prev Med Bull. 2007; 6(3: 221-226

  13. Residential indoor air quality guideline : ozone

    International Nuclear Information System (INIS)

    2010-01-01

    Ozone (O 3 ) is a colourless gas that reacts rapidly on surfaces and with other constituents in the air. Sources of indoor O 3 include devices sold as home air cleaners, and some types of office equipment. Outdoor O 3 is also an important contributor to indoor levels of O 3 , depending on the air exchange rate with indoor environments. This residential indoor air quality guideline examined factors that affect the introduction, dispersion and removal of O 3 indoors. The health effects of prolonged exposure to O 3 were discussed, and studies conducted to evaluate the population health impacts of O 3 were reviewed. The studies demonstrated that there is a significant association between ambient O 3 and adverse health impacts. Exposure guidelines for residential indoor air quality were discussed. 14 refs.

  14. Reconstruction of national distribution of indoor radon concentration in Russia using results of regional indoor radon measurement programs

    International Nuclear Information System (INIS)

    Yarmoshenko, I.; Malinovsky, G.; Vasilyev, A.; Zhukovsky, M.

    2015-01-01

    The aim of the paper is a reconstruction of the national distribution and estimation of the arithmetic average indoor radon concentration in Russia using the data of official annual 4-DOZ reports. Annual 4-DOZ reports summarize results of radiation measurements in 83 regions of Russian Federation. Information on more than 400 000 indoor radon measurements includes the average indoor radon isotopes equilibrium equivalent concentration (EEC) and number of measurements by regions and by three main types of houses: wooden, one-storey non-wooden, and multi-storey non-wooden houses. To reconstruct the national distribution, all-Russian model sample was generated by integration of sub-samples created using the results of each annual regional program of indoor radon measurements in each type of buildings. According to indoor radon concentration distribution reconstruction, all-Russian average indoor radon concentration is 48 Bq/m"3. Average indoor radon concentration by region ranges from 12 to 207 Bq/m"3. The 95-th percentile of the distribution is reached at indoor radon concentration 160 Bq/m"3. - Highlights: • Reconstruction of indoor radon concentration distribution in Russia was carried out. • Data of official annual 4-DOZ reports were used. • All-Russian average indoor radon concentration is 48 Bq/m"3. • The 95-th percentile is 160 Bq/m"3.

  15. Slovak Republic, indoor measurements

    International Nuclear Information System (INIS)

    Vicanova, M.; Daniel, S.

    2006-01-01

    In this report the annual average effective doses from indoor radon exposure were calculated for each district of Slovakia. The population-weighted arithmetic mean of indoor radon concentration was calculated for every district considering different types of houses.

  16. Indoor Tanning Dependence in Young Adult Women.

    Science.gov (United States)

    Mays, Darren; Atkins, Michael B; Ahn, Jaeil; Tercyak, Kenneth P

    2017-11-01

    Background: There is mounting evidence that young people can develop a dependence on indoor tanning, but research on factors associated with indoor tanning dependence remains limited. Methods: This cross-sectional study investigated factors associated with indoor tanning dependence in a community sample of 389 non-Hispanic white young adult women ages 18 to 30 who had indoor tanned ≥1 time in the past year. Participants completed measures of indoor tanning dependence, including the modified CAGE and modified Diagnostic and Statistical Manual for Mental Disorders-IV psychiatric screening assessments, indoor tanning behavior and beliefs, and behavioral and psychiatric comorbidity. Results: Overall, 22.6% of the sample screened positive for indoor tanning dependence. In multivariable analyses, indoor tanning dependence was associated with younger age of indoor tanning initiation [adjusted odds ratio (aOR) = 0.79; P = 0.017], indoor tanning ≥20 times in the past year (aOR = 3.03; P = 0.015), stronger beliefs about the benefits of tanning (aOR = 2.15; P = 0.004), greater perceived susceptibility to indoor tanning risks (aOR = 2.72; P tanning dependence among young, non-Hispanic white women is associated with behaviors that increase the risk of skin cancer, beliefs favoring the perceived benefits of tanning, and comorbid risks such as stronger beliefs about physical appearance and depressed mood. Impact: Comprehensive skin cancer prevention efforts should address indoor tanning dependence among young women and its leading risk factors. Cancer Epidemiol Biomarkers Prev; 26(11); 1636-43. ©2017 AACR . ©2017 American Association for Cancer Research.

  17. Indoor air quality – buildings design

    Directory of Open Access Journals (Sweden)

    Juhásová Šenitková Ingrid

    2017-01-01

    Full Text Available Growing attention is being paid to indoor air quality as one of the main health and well-being factors. The indoor research is concerned mostly to indoor air chemicals within indoor engineering related to building design. The providing good indoor air quality can be achieved effectively by avoiding or reducing indoor air pollution sources and by selecting low-polluting building materials, both being low-cost and energyefficient solutions. On the base of the last large experimental monitoring results, it was possible to know the level of selected indoor chemicals occurrence, rank them as well as to predict the tendencies of occurrence and establish the priorities for the future. There has been very limited attention to rigorous analysis of buildings actual environmental impacts to date. Healthy/green/sustainable building practices are typically applied in unsystematic and inconsistent ways often without resolution of inherent conflicts between and among such practices. Designers, products manufacturers, constructors, and owners declare their buildings and the applied technologies to be beneficial to the environment without validating those claims.

  18. State Indoor Tanning Laws and Prevalence of Indoor Tanning Among US High School Students, 2009-2015.

    Science.gov (United States)

    Qin, Jin; Holman, Dawn M; Jones, Sherry Everett; Berkowitz, Zahava; Guy, Gery P

    2018-07-01

    To examine the association between state indoor tanning laws and indoor tanning behavior using nationally representative samples of US high school students younger than 18 years. We combined data from the 2009, 2011, 2013, and 2015 national Youth Risk Behavior Surveys (n = 41 313) to analyze the association between 2 types of state indoor tanning laws (age restriction and parental permission) and the prevalence of indoor tanning during the 12 months before the survey, adjusting for age, race/ethnicity, and survey year, and stratified by gender. Age restriction laws were associated with a 47% (P tanning prevalence among female high school students. Parental permission laws were not found to be associated with indoor tanning prevalence among either female or male high school students. Age restriction laws could contribute to less indoor tanning, particularly among female high school students. Such reductions may reduce the health and economic burden of skin cancer.

  19. Workshop on indoor air quality research needs

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized. (DLS)

  20. Workshop on indoor air quality research needs

    International Nuclear Information System (INIS)

    1980-01-01

    Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized

  1. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  2. Accurate estimation of indoor travel times

    DEFF Research Database (Denmark)

    Prentow, Thor Siiger; Blunck, Henrik; Stisen, Allan

    2014-01-01

    The ability to accurately estimate indoor travel times is crucial for enabling improvements within application areas such as indoor navigation, logistics for mobile workers, and facility management. In this paper, we study the challenges inherent in indoor travel time estimation, and we propose...... the InTraTime method for accurately estimating indoor travel times via mining of historical and real-time indoor position traces. The method learns during operation both travel routes, travel times and their respective likelihood---both for routes traveled as well as for sub-routes thereof. InTraTime...... allows to specify temporal and other query parameters, such as time-of-day, day-of-week or the identity of the traveling individual. As input the method is designed to take generic position traces and is thus interoperable with a variety of indoor positioning systems. The method's advantages include...

  3. Indoor ionizing radiation

    International Nuclear Information System (INIS)

    Ericson, S.O.; Lindvall, T.; Maansson, L-G.

    1986-01-01

    Radiation in indoor air is discussed in the perspective of the effective dose equivalents from other sources of radiation. Estimates of effective doses equivalents from indoor radon and its contribution to lung cancer incidence are reviewed. Swedish experiences with cost effective remedial actions are presented. The authors present optimal strategies for screening measurements and remedial actions in cost-benefit perspective. (author.)

  4. Indoor air quality in Brazilian universities.

    Science.gov (United States)

    Jurado, Sonia R; Bankoff, Antônia D P; Sanchez, Andrea

    2014-07-11

    This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC) (n = 15) and naturally ventilated (NV) (n = 15) classrooms. The parameters of interest were indoor carbon dioxide (CO2), temperature, relative humidity (RH), wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively). The average indoor airborne dust concentration exceeded the Brazilian standards (indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem.

  5. Investigations on indoor radon in Austria, Part 1: Seasonality of indoor radon concentration

    International Nuclear Information System (INIS)

    Bossew, Peter; Lettner, Herbert

    2007-01-01

    In general, indoor radon concentration is subject to seasonal variability. The reasons are to be found (1) in meteorological influence on the transport properties of soil, e.g. through temperature, frozen soil layers and soil water saturation; and (2) in living habits, e.g. the tendency to open windows in summer and keep them closed in winter, which in general leads to higher accumulation of geogenic Rn in closed rooms in winter. If one wants to standardize indoor Rn measurements originally performed at different times of the year, e.g. in order to make them comparable, some correction transform as a function of measurement time which accounts for these effects must be estimated. In this paper, the seasonality of indoor Rn concentration measured in Austria is investigated as a function of other factors that influence indoor Rn. Indoor radon concentration is clearly shown to have seasonal variability, with higher Rn levels in winter. However, it is complicated to quantify the effect because, as a consequence of the history of an Rn survey, the measurement season maybe correlated to geological regions, which may introduce a bias in the estimate of the seasonality amplitude

  6. Internet-Based Indoor Navigation Services

    OpenAIRE

    Zeinalipour-Yazti, Demetrios; Laoudias, Christos; Georgiou, Kyriakos

    2017-01-01

    Smartphone advances are leading to a class of Internet-based Indoor Navigation services. IIN services rely on geolocation databases that store indoor models, comprising floor maps and points of interest, along with wireless, light, and magnetic signals for localizing users. Developing IIN services creates new information management challenges - such as crowdsourcing indoor models, acquiring and fusing big data velocity signals, localization algorithms, and custodians' location privacy. Here, ...

  7. Estimation of the variations of ventilation rate and indoor radon concentration using the observed wind velocity and indoor-outdoor temperature difference

    International Nuclear Information System (INIS)

    Nagano, Katsuhiro; Inose, Yuichi; Kojima, Hiroshi

    2006-01-01

    The indoor radon concentration in the building depends on the ventilation rate. Measurement results of indoor-outdoor pressure difference showed the ventilation rate correlated closely with the indoor-outdoor pressure difference. The observation results showed that one of factor of indoor-outdoor pressure difference was the wind velocity. When the wind velocity is small, the ventilation rate is affected by the indoor-outdoor temperature difference and the effect depends on the wind velocity. The temporal variation of indoor radon concentration was predicted by the time depending indoor radon balance model and the ventilation rate estimated from the wind velocity and the indoor-outdoor temperature difference. The temporal variations of predicted radon concentration gave good agreement with the experimental values. The measurement method, indoor radon concentration and ventilation rate, factors of temporal variation of ventilation rate, and prediction of indoor radon concentration are reported. (S.Y.)

  8. The Isprs Benchmark on Indoor Modelling

    Science.gov (United States)

    Khoshelham, K.; Díaz Vilariño, L.; Peter, M.; Kang, Z.; Acharya, D.

    2017-09-01

    Automated generation of 3D indoor models from point cloud data has been a topic of intensive research in recent years. While results on various datasets have been reported in literature, a comparison of the performance of different methods has not been possible due to the lack of benchmark datasets and a common evaluation framework. The ISPRS benchmark on indoor modelling aims to address this issue by providing a public benchmark dataset and an evaluation framework for performance comparison of indoor modelling methods. In this paper, we present the benchmark dataset comprising several point clouds of indoor environments captured by different sensors. We also discuss the evaluation and comparison of indoor modelling methods based on manually created reference models and appropriate quality evaluation criteria. The benchmark dataset is available for download at: html"target="_blank">http://www2.isprs.org/commissions/comm4/wg5/benchmark-on-indoor-modelling.html.

  9. Controlling Indoor Air Pollution from Moxibustion

    Directory of Open Access Journals (Sweden)

    Chung-Yen Lu

    2016-06-01

    Full Text Available Indoor air quality (IAQ control of hospitals plays a critical role in protecting both hospital staffs and patients, particularly those who are highly susceptible to the adverse effects of indoor noxious hazards. However, moxibustion in outpatient departments (OPDs of traditional Chinese medicine (TCM may be a source of indoor air pollution in hospitals. Some studies have investigated indoor air pollution during moxibustion in Chinese medicine clinics (CMCs and moxibustion rooms, demonstrating elevated air pollutants that pose a threat to the health of medical staff and patients. Our study investigated the indoor air pollutants of indoor carbon dioxide (CO2, carbon monoxide (CO, formaldehyde (HCHO, total volatile organic compounds (TVOCs, airborne particulate matter with a diameter of ≤10 µm (PM10 and ≤2.5 µm (PM2.5 during moxibustion in an acupuncture and moxibustion room of the OPD in a hospital in Taipei. To evaluate the different control strategies for indoor air pollution from moxibution, a comparison of air pollutants during moxibution among the methods of using alternative old moxa wools, local exhaust ventilation and an air cleaner was conducted. In this study, burning alternative old moxa wools for moxibustion obviously reduced all gaseous pollutants except for aerosols comparing burning fresh moxa wools. Using local exhaust ventilation reduced most of the aerosols after burning moxa. We also found that using an air cleaner was inefficient for controlling indoor air pollutants, particularly gaseous pollutants. Therefore, combining replacing alternative old moxa wools and local exhaust ventilation could be a suitable design for controlling indoor air pollution during moxibustion therapy.

  10. Multi-dimensional indoor location information model

    NARCIS (Netherlands)

    Xiong, Q.; Zhu, Q.; Zlatanova, S.; Huang, L.; Zhou, Y.; Du, Z.

    2013-01-01

    Aiming at the increasing requirements of seamless indoor and outdoor navigation and location service, a Chinese standard of Multidimensional Indoor Location Information Model is being developed, which defines ontology of indoor location. The model is complementary to 3D concepts like CityGML and

  11. NFC Internal: An Indoor Navigation System

    Science.gov (United States)

    Ozdenizci, Busra; Coskun, Vedat; Ok, Kerem

    2015-01-01

    Indoor navigation systems have recently become a popular research field due to the lack of GPS signals indoors. Several indoors navigation systems have already been proposed in order to eliminate deficiencies; however each of them has several technical and usability limitations. In this study, we propose NFC Internal, a Near Field Communication (NFC)-based indoor navigation system, which enables users to navigate through a building or a complex by enabling a simple location update, simply by touching NFC tags those are spread around and orient users to the destination. In this paper, we initially present the system requirements, give the design details and study the viability of NFC Internal with a prototype application and a case study. Moreover, we evaluate the performance of the system and compare it with existing indoor navigation systems. It is seen that NFC Internal has considerable advantages and significant contributions to existing indoor navigation systems in terms of security and privacy, cost, performance, robustness, complexity, user preference and commercial availability. PMID:25825976

  12. Introduction to Indoor Air Quality

    Science.gov (United States)

    ... Offices Regional Offices Labs and Research Centers Indoor Air Quality (IAQ) Contact Us Share Introduction to Indoor Air Quality Health Effects Primary Causes Identifying Problems Improving IAQ ...

  13. Indoor Air Quality in Schools

    Science.gov (United States)

    This web site will educate the public about indoor environmental issues specific to educational facilities and the importance of developing and sustaining comprehensive indoor air quality management programs.

  14. 9 CFR 3.102 - Facilities, indoor.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Facilities, indoor. 3.102 Section 3... Marine Mammals Facilities and Operating Standards § 3.102 Facilities, indoor. (a) Ambient temperature. The air and water temperatures in indoor facilities shall be sufficiently regulated by heating or...

  15. INDOOR AIR POLLUTION

    OpenAIRE

    Ahmet Soysal; Yucel Demiral

    2007-01-01

    The existance of hazardious materials including biological, chemical, and physical agents such as carbon dioxide, carbon monoxide, sulphur dioxide, nitrogen oxides, radon, volotile organic compounds, microorganisms in houses and the other non-industrilized buildings have been defined as “indoor air pollution”. Indoor air pollutants could possible arised from inside or outside environment and categorized into six subgroups. Almost 80% Turkish population have living in the urban areas...

  16. Indoor Multi-Dimensional Location GML and Its Application for Ubiquitous Indoor Location Services

    NARCIS (Netherlands)

    Zhu, Qing; Li, Yun; Xiong, Qing; Zlatanova, S.; Ding, Yulin; Zhang, Yeting; Zhou, Yan

    2016-01-01

    The Open Geospatial Consortium (OGC) Geography Markup Language (GML) standard provides basic types and a framework for defining geo-informational data models such as CityGML and IndoorGML, which provide standard information models for 3D city modelling and lightweight indoor network navigation.

  17. Capturing Hotspots For Constrained Indoor Movement

    DEFF Research Database (Denmark)

    Ahmed, Tanvir; Pedersen, Torben Bach; Lu, Hua

    2013-01-01

    Finding the hotspots in large indoor spaces is very important for getting overloaded locations, security, crowd management, indoor navigation and guidance. The tracking data coming from indoor tracking are huge in volume and not readily available for finding hotspots. This paper presents a graph......-based model for constrained indoor movement that can map the tracking records into mapping records which represent the entry and exit times of an object in a particular location. Then it discusses the hotspots extraction technique from the mapping records....

  18. Ventilation influence upon indoor air radon level

    International Nuclear Information System (INIS)

    Tian Deyuan

    1995-01-01

    Levels of indoor radon in air are studied by a continuous electrostatic radon monitor under normal living conditions to evaluate the influence of air conditioned ventilation on indoor air radon level. Results show that the indoor air radon concentrations are not much more than those without household conditioner living condition, although using household conditioner requires a sealed room which should lead to a higher radon level. Turning on air conditioner helps lower indoor radon level. Therefore, the total indoor air Rn levels are normal > ventilation > exhaust or in-draft > exhaust plus in-draft

  19. Managing Indoor Air Quality in Schools.

    Science.gov (United States)

    Woolums, Jennifer

    This publication examines the causes and effects of poor indoor air quality and provides information for reducing exposure to indoor contaminants in schools. It discusses the various indoor pollutants found in schools, including dust, chemical agents, gases, and volatile organic compounds; where they are found in schools; and their health effects…

  20. Indoor climate design for a monumental building with periodic high indoor moisture loads

    NARCIS (Netherlands)

    Schijndel, van A.W.M.; Lony, R.J.M.; Schellen, H.L.

    2008-01-01

    The paper presents a case study on the performance based design for the indoor climate of a monumental building with periodic high indoor moisture loads. Several scenarios of the past performance and new control classes are simulated and evaluated. The results include the influence of hygric inertia

  1. Indoor air quality: a UK perspective

    International Nuclear Information System (INIS)

    Wadge, A.

    1995-01-01

    Outdoor air quality has generally improved in the UK over the last 2 decades but during this period changing conditions within the home have tended to reduce ventilation and increase the opportunity for accumulation of undesirable levels of indoor air pollutants. Information obtained from laboratory and epidemiological studies suggest that indoor air pollutants are an important cause of avoidable morbidity and mortality in the UK. This paper reviews the major indoor air pollutants of concern in the UK and considers some of the special issues relevant to indoor environment. (author) 3 figs., 37 refs

  2. Indoor localization using magnetic fields

    Science.gov (United States)

    Pathapati Subbu, Kalyan Sasidhar

    Indoor localization consists of locating oneself inside new buildings. GPS does not work indoors due to multipath reflection and signal blockage. WiFi based systems assume ubiquitous availability and infrastructure based systems require expensive installations, hence making indoor localization an open problem. This dissertation consists of solving the problem of indoor localization by thoroughly exploiting the indoor ambient magnetic fields comprising mainly of disturbances termed as anomalies in the Earth's magnetic field caused by pillars, doors and elevators in hallways which are ferromagnetic in nature. By observing uniqueness in magnetic signatures collected from different campus buildings, the work presents the identification of landmarks and guideposts from these signatures and further develops magnetic maps of buildings - all of which can be used to locate and navigate people indoors. To understand the reason behind these anomalies, first a comparison between the measured and model generated Earth's magnetic field is made, verifying the presence of a constant field without any disturbances. Then by modeling the magnetic field behavior of different pillars such as steel reinforced concrete, solid steel, and other structures like doors and elevators, the interaction of the Earth's field with the ferromagnetic fields is described thereby explaining the causes of the uniqueness in the signatures that comprise these disturbances. Next, by employing the dynamic time warping algorithm to account for time differences in signatures obtained from users walking at different speeds, an indoor localization application capable of classifying locations using the magnetic signatures is developed solely on the smart phone. The application required users to walk short distances of 3-6 m anywhere in hallway to be located with accuracies of 80-99%. The classification framework was further validated with over 90% accuracies using model generated magnetic signatures representing

  3. A study on the risk from indoor radon 220 and radon 222 exposures

    International Nuclear Information System (INIS)

    Rannou, A.

    1986-12-01

    The hazards from radon (radon 220 and 222) in dwelling atmospheres have been studied. In the first part devoted to the present state of the problem, an analysis is made of the formation mechanisms and the evolution of radon and its daughters indoors. The main physical and dosimetric quantities required for the risk evaluation are defined. The theoretical and experimental analysis of the methods of measurements of radon and its daughters used in the measurement campaign are considered in the second part. The progress and the result of the national survey are developed in the third part. The effects of several factors on indoor levels are discussed. The conclusions of a particular study in the Finistere ''department'' are presented. The data collected make it possible to assess the mean exposure of man to natural radiation [fr

  4. Diffusion of hydrogen in iron oxides

    International Nuclear Information System (INIS)

    Bruzzoni, P.

    1993-01-01

    The diffusion of hydrogen in transitions metals oxides has been recently studied at room temperature through the permeability electrochemical technique. This work studies thin oxide layers grown in air or in presence of oxidizing atmospheres at temperatures up to 200 deg C. The substrate was pure iron with different superficial treatments. It was observed that these oxides reduce up to three magnitudes orders, the hydrogen stationary flux through membranes of usual thickness in comparison with iron membranes free of oxide. (Author)

  5. Diurnal variations of indoor radon progeny for Bangalore metropolitan, India

    International Nuclear Information System (INIS)

    Nagesh, V.; Sathish, L.A.; Nagaraja, K.; Sundareshan, S.

    2010-01-01

    Radon progenies are identified as major causes of the lung cancer if the activity is above its normal. It has not been clear whether radon poses a similar risk of causing lung cancer in humans exposed at generally lower levels found in homes, but a number of indoor radon survey have been carried out in recent years around the world. In view of this an attempt has been made for the measurement of diurnal variation of indoor radon levels for the environment of Bangalore metropolitan, India. The Radon progeny concentrations in terms of working level were measured using Kusnetz's method. The patterns of daily and annual changes in indoor Radon concentration have been observed in a general way for many years. However, understanding of the physical basis for these changes had to await the development of continuous monitors and a more complete knowledge of transport processes in the atmosphere. Over a continent, heating of the ground surface by the Sun during the day and cooling by radiation during the night causes a marked diurnal change in temperature near the surface. As a result cool air near the ground will accumulate radon isotopes from surface flux during the night; while during the day the warm air will be transported upward carrying radon with it. Many buildings show diurnal radon variations. Concentrations are relatively higher during night than daytime. This is influenced by the outdoor-indoor temperature contrast. This effect can be enhanced in buildings with strong diurnal use patterns. Buildings that have high average radon concentrations, but are only occupied for part of the day, may need to be measured during occupied periods to determine if there is significant diurnal radon variation. The results are discussed in detail. (author)

  6. An indoor chemical cocktail

    Science.gov (United States)

    Gligorovski, Sasho; Abbatt, Jonathan P. D.

    2018-02-01

    In the past 50 years, many of the contaminants and chemical transformations that occur in outdoor waters, soils, and air have been elucidated. However, the chemistry of the indoor environment in which we live most of the time—up to 90% in some societies—is not nearly as well studied. Recent work has highlighted the wealth of chemical transformations that occur indoors. This chemistry is associated with 3 of the top 10 risk factors for negative health outcomes globally: household air pollution from solid fuels, tobacco smoking, and ambient particulate matter pollution (1). Assessments of human exposure to indoor pollutants must take these reactive processes into consideration.

  7. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    Science.gov (United States)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  8. Reducing indoor residential exposures to outdoor pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Matson, Nance E.

    2003-07-01

    The basic strategy for providing indoor air quality in residences is to dilute indoor sources with outdoor air. This strategy assumes that the outdoor air does not have pollutants at harmful levels or that the outdoor air is, at least, less polluted than the indoor air. When this is not the case, different strategies need to be employed to ensure adequate air quality in the indoor environment. These strategies include ventilation systems, filtration and other measures. These strategies can be used for several types of outdoor pollution, including smog, particulates and toxic air pollutants. This report reviews the impacts that typical outdoor air pollutants can have on the indoor environment and provides design and operational guidance for mitigating them. Poor quality air cannot be used for diluting indoor contaminants, but more generally it can become an indoor contaminant itself. This paper discusses strategies that use the building as protection against potentially hazardous outdoor pollutants, including widespread pollutants, accidental events, and potential attacks.

  9. [Health evaluation of fine particulate matter in indoor air].

    Science.gov (United States)

    2008-11-01

    When evaluating the health effects of indoor air fine particulate matter, the indoor dynamics as well as the physical, chemical and biological properties of fine particles have to be considered. The indoor air fraction PM2.5 largely stems from outdoor air. Accordingly, the German Working Group on Indoor Guideline Values of the Federal Environmental Agency and the States' Health Authorities also recommends WHO's (2006) 24-hour mean guideline value of 25 microg PM2,5 per cubic meter for indoor air evaluation. In contrast to PM2.5, coarse particles (PM10) in schools, kindergartens and dwellings show much higher indoor air concentrations. Additional sources indoors have to be assumed. Because of the different composition of indoor air compared to outdoor air and due to the lack of dose-response relationships of coarse particles in indoor air, the health effects of indoor air PM10 can not be evaluated yet. Sufficient and consistent ventilation is an indispensable basis to reduce PM concentrations in indoor spaces. Furthermore, known sources of PM indoors should be detected consequently and subsequently minimized.

  10. NFC Internal: An Indoor Navigation System

    Directory of Open Access Journals (Sweden)

    Busra Ozdenizci

    2015-03-01

    Full Text Available Indoor navigation systems have recently become a popular research field due to the lack of GPS signals indoors. Several indoors navigation systems have already been proposed in order to eliminate deficiencies; however each of them has several technical and usability limitations. In this study, we propose NFC Internal, a Near Field Communication (NFC-based indoor navigation system, which enables users to navigate through a building or a complex by enabling a simple location update, simply by touching NFC tags those are spread around and orient users to the destination. In this paper, we initially present the system requirements, give the design details and study the viability of NFC Internal with a prototype application and a case study. Moreover, we evaluate the performance of the system and compare it with existing indoor navigation systems. It is seen that NFC Internal has considerable advantages and significant contributions to existing indoor navigation systems in terms of security and privacy, cost, performance, robustness, complexity, user preference and commercial availability.

  11. Assessment of external dose indoors in Lithuania

    International Nuclear Information System (INIS)

    Pilkyte, L.; Butkus, D.; Morkunas, G.

    2006-01-01

    The aim of this paper was an assessment of external exposure indoors and its dependence on construction materials and indoor radon concentrations in Lithuanian living houses. Relationship of absorbed dose rate in air indoors and activity indexes of the most commonly used construction materials (wood, concrete and bricks) have been studied using results received in measurements done in >4700 rooms in 1995-2005. Possible connections of dose rate indoors with indoor radon concentrations are also discussed. Findings of this study helped to make an assessment of the mean value of effective dose of Lithuanian population due to external exposure indoors which is equal to 0.58 mSv y -1 . The received data might also be used in improvement of quality of personal dosimetric measurements done in premises constructed of different construction materials. (authors)

  12. Residential indoor air quality guideline : carbon monoxide

    International Nuclear Information System (INIS)

    2010-01-01

    Carbon monoxide (CO) is a tasteless, odourless, and colourless gas that can be produced by both natural and anthropogenic processes, but is most often formed during the incomplete combustion of organic materials. In the indoor environment, CO occurs directly as a result of emissions from indoor sources or as a result of infiltration from outdoor air containing CO. Studies have shown that the use of specific sources can lead to increased concentrations of CO indoors. This residential indoor air quality guideline examined the factors influencing the introduction, dispersion and removal of CO indoors. The health effects of exposure to low and higher concentrations of CO were discussed. Residential maximum exposure limits for CO were presented. Sources and concentrations in indoor environments were also examined. 17 refs., 2 tabs.

  13. Semivolatile organic compounds in indoor environments

    DEFF Research Database (Denmark)

    Weschler, Charles J.; Nazaroff, W.W.

    2008-01-01

    Semivolatile organic compounds (SVOCs) are ubiquitous in indoor environments, redistributing from their original sources to all indoor surfaces. Exposures resulting from their indoor presence contribute to detectable body burdens of diverse SVOCs, including pesticides, plasticizers, and flame ret...... remarkably well with levels measured in dermal hand wipes for SVOCs possessing a wide range of octanol-air partition coefficients....

  14. Characterization of reaction products of iron and iron salts and aqueous plant extracts

    Energy Technology Data Exchange (ETDEWEB)

    Jaen, J.A. [Universidad de Panama, Centro de Investigaciones con Tecnicas Nucleares/Depto. de Quimica (Panama); Garcia de Saldana, E.; Hernandez, C. [Universidad de Panama, Maestria en Ciencias Quimicas (Panama)

    1999-11-15

    The complexes formed in aqueous solution as a result of a reaction of iron and iron salts (Fe{sup 2+} and Fe{sup 3+}) and some plant extracts were analyzed using Moessbauer spectroscopy and Fourier transform infrared. The extracts were obtained from Opuntia elatior mill., Acanthocereus pentagonus (L.) Britton, Mimosa tenuiflora, Caesalpinia coriaria (Jacq.) Willd., Bumbacopsis quinata (Jacq.) Dugand and Acacia mangium Willd., plants growing wildly in different zones of the Isthmus of Panama. Results suggest the formation of mono- and bis-type complexes, and in some cases, the occurrence of a redox reaction. The feasibility of application of the studied extracts as atmospheric corrosion inhibitors is discussed.

  15. A Semantic-Based Indexing for Indoor Moving Objects

    OpenAIRE

    Tingting Ben; Xiaolin Qin; Ning Wang

    2014-01-01

    The increasing availability of indoor positioning, driven by techniques like RFID, Bluetooth, and smart phones, enables a variety of indoor location-based services (LBSs). Efficient queries based on semantic-constraint in indoor spaces play an important role in supporting and boosting LBSs. However, the existing indoor index techniques cannot support these semantic constraints-based queries. To solve this problem, this paper addresses the challenge of indexing moving objects in indoor spaces,...

  16. Indoor Positioning using Wi-Fi

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Krarup, Mads Vering; Stisen, Allan

    The past decade has witnessed substantial research on methods for indoor Wi-Fi positioning. While much effort has gone into achieving high positioning accuracy and easing fingerprint collection, it is our contention that the general problem is not sufficiently well understood, thus preventing...... deployments and their usage by applications to become more widespread. Based on our own and published experiences on indoor Wi-Fi positioning deployments, we hypothesize the following: Current indoor Wi-Fi positioning systems and their utilization in applications are hampered by the lack of understanding...... of the requirements present in the real-world deployments. In this paper, we report findings from qualitatively studying organisational requirements for indoor Wi-Fi positioning. The studied cases and deployments cover both company and public-sector settings and the deployment and evaluation of several types...

  17. Indoor Air Pollution (Environmental Health Student Portal)

    Science.gov (United States)

    ... Students to Environmental Health Information Menu Home Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ... Pollution Indoor Air Pollution Print this Page Air Pollution Air Pollution Home Indoor Air Pollution Outdoor Air Pollution ...

  18. Indoor Air Quality Manual.

    Science.gov (United States)

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  19. Indoor Climate of Large Glazed Spaces

    DEFF Research Database (Denmark)

    Hendriksen, Ole Juhl; Madsen, Christina E.; Heiselberg, Per

    In recent years large glazed spaces has found increased use both in connection with renovation of buildings and as part of new buildings. One of the objectives is to add an architectural element, which combines indoor- and outdoor climate. In order to obtain a satisfying indoor climate it is crui...... it is cruicial at the design stage to be able to predict the performance regarding thermal comfort and energy consumption. This paper focus on the practical implementation of Computational Fluid Dynamics (CFD) and the relation to other simulation tools regarding indoor climate.......In recent years large glazed spaces has found increased use both in connection with renovation of buildings and as part of new buildings. One of the objectives is to add an architectural element, which combines indoor- and outdoor climate. In order to obtain a satisfying indoor climate...

  20. Solubility of iron from combustion source particles in acidic media linked to iron speciation.

    Science.gov (United States)

    Fu, Hongbo; Lin, Jun; Shang, Guangfeng; Dong, Wenbo; Grassian, Vichi H; Carmichael, Gregory R; Li, Yan; Chen, Jianmin

    2012-10-16

    In this study, iron solubility from six combustion source particles was investigated in acidic media. For comparison, a Chinese loess (CL) dust was also included. The solubility experiments confirmed that iron solubility was highly variable and dependent on particle sources. Under dark and light conditions, the combustion source particles dissolved faster and to a greater extent relative to CL. Oil fly ash (FA) yielded the highest soluble iron as compared to the other samples. Total iron solubility fractions measured in the dark after 12 h ranged between 2.9 and 74.1% of the initial iron content for the combustion-derived particles (Oil FA > biomass burning particles (BP) > coal FA). Ferrous iron represented the dominant soluble form of Fe in the suspensions of straw BP and corn BP, while total dissolved Fe presented mainly as ferric iron in the cases of oil FA, coal FA, and CL. Mössbauer measurements and TEM analysis revealed that Fe in oil FA was commonly presented as nanosized Fe(3)O(4) aggregates and Fe/S-rich particles. Highly labile source of Fe in corn BP could be originated from amorphous Fe form mixed internally with K-rich particles. However, Fe in coal FA was dominated by the more insoluble forms of both Fe-bearing aluminosilicate glass and Fe oxides. The data presented herein showed that iron speciation varies by source and is an important factor controlling iron solubility from these anthropogenic emissions in acidic solutions, suggesting that the variability of iron solubility from combustion-derived particles is related to the inherent character and origin of the aerosols themselves. Such information can be useful in improving our understanding on iron solubility from combustion aerosols when they undergo acidic processing during atmospheric transport.

  1. Geologic influence on indoor radon concentrations and gamma radiation levels in Norwegian dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Sundal, Aud Venche

    2003-09-01

    Indoor radon levels in 1618 Norwegian dwellings located in different geological settings were compared with geological information in order to determine potential correlations between geological factors and indoor radon concentrations in Norway and to establish whether geological information is useful in radon risk analysis. In two geographically limited areas, Kinsarvik and Fen, detailed geological and geochemical investigations were carried out in order to explain their elevated natural radiation environment. Significant correlations between geology and indoor radon concentrations in Norway are found when the properties of both the bedrock and the overburden are taken into account. Areas of high radon risk in Norway include 1) exposed bedrock with elevated levels of radium (mainly alum shale and granites) and b) highly permeable unconsolidated sediments derived from all rock types (mainly glaciofluvial and fluvial deposits) and moderately permeable sediments containing radium rich rock fragments (mainly basal till). More than 20 % of Norwegian dwellings located in the high-risk areas can be expected to contain radon levels exceeding 200 Bq/m3. The elevated radon risk related to penneable building grounds is illustrated in Kinsarvik where the highly permeable sediments and the large vadose zone underlying the Huse residential area enable the transport of radon from large volumes into the dwellings resulting in enhanced indoor radon concentrations. Subterranean air flows caused by temperature/pressure differences between soil air and atmospheric air and elevations differences within the Huse area are shown to strongly affect the annual variations in indoor radon concentrations. The marked contrasts in radon risk potential between different types of building grounds are clearly illustrated in the Fen area where outcrops of the radium rich Fen carbonatites represent areas of high radon risk while only low levels of both indoor radon concentrations and indoor gamma

  2. Exposure to indoor air pollution in a reconstructed house from Danish Iron Age

    DEFF Research Database (Denmark)

    Skov, Henrik; Christensen, Carsten Stentoft; Fenger, Jes

    2000-01-01

    The adverse effects of air pollution on health have been recognised for millennia, but only in recent centuries they have been directly documented. In this paper evidence of the levels of exposure in the Danish Iron Age has been obtained from real measurements. The personal exposure to NO2...

  3. Indoor and outdoor atmospheric fungal spores in the São Paulo metropolitan area (Brazil): species and numeric concentrations

    Science.gov (United States)

    Gonçalves, Fábio Luiz Teixeira; Bauer, Heidi; Cardoso, Maria Regina Alves; Pukinskas, Sandra; Matos, Dulcilena; Melhem, Márcia; Puxbaum, Hans

    2010-07-01

    The aim of this study was to estimate the indoor and outdoor concentrations of fungal spores in the Metropolitan Area of Sao Paulo (MASP), collected at different sites in winter/spring and summer seasons. The techniques adopted included cultivation (samples collected with impactors) and microscopic enumeration (samples collected with impingers). The overall results showed total concentrations of fungal spores as high as 36,000 per cubic meter, with a large proportion of non culturable spores (around 91% of the total). Penicillium sp. and Aspergillus sp. were the dominant species both indoors and outdoors, in all seasons tested, occurring in more than 30% of homes at very high concentrations of culturable airborne fungi [colony forming units(CFU) m-3]. There was no significant difference between indoor and outdoor concentrations. The total fungal spore concentration found in winter was 19% higher than that in summer. Heat and humidity were the main factors affecting fungal growth; however, a non-linear response to these factors was found. Thus, temperatures below 16°C and above 25°C caused a reduction in the concentration (CFU m-3) of airborne fungi, which fits with MASP climatalogy. The same pattern was observed for humidity, although not as clearly as with temperature given the usual high relative humidity (above 70%) in the study area. These results are relevant for public health interventions that aim to reduce respiratory morbidity among susceptible populations.

  4. The role of copper and oxalate in the redox cycling of iron in atmospheric waters

    Science.gov (United States)

    Sedlak, David L.; Hoigné, Jürg

    During daytime, the redox cycling of dissolved iron compounds in atmospheric waters, and the related in-cloud transformations of photooxidants, are affected by reactions of Fe and Cu with hydroperoxy (HO 2) and superoxide (O 2-) radicals and the photoreduction of Fe(III)-oxalato complexes. We have investigated several of the important chemical reactions in this redox cycle, through laboratory simulation of the system, using γ-radiation to produce HO 2/O 2-. At concentrations comparable to those measured in atmospheric waters, the redox cycling of Fe was dramatically affected by the presence of oxalate and trace concentrations of Cu. At concentrations more than a hundred times lower than Fe, Cu consumed most of the HO 2/O 2-, and cycled between the Cu(II) and Cu(I) forms. Cu + reacted with FeOH 2+ to produce Fe(II) and Cu(II), with a second order rate constant of approximately 3 × 10 7 M -1s -1. The presence of oxalate resulted in the formation of Fe(III)-oxalato complexes that were essentially unreactive with HO 2/O 2-. Only at high oxalate concentrations was the Fe(II)C 2O 4 complex also formed, and it reacted relatively rapidly with hydrogen peroxide ( k = (3.1 ± 0.6) × 10 4 M -1s -1). Simulations incorporating measurements for other redox mechanisms, including oxidation by ozone, indicate that, during daytime, Fe should be found mostly in the ferrous oxidation state, and that reactions of FeOH 2+ with Cu(I) and HO 2/O 2-, and to a lesser degree, the photolysis of Fe(III)-oxalato complexes, are important mechanisms of Fe reduction in atmospheric waters. The catalytic effect of Cu(II)/Cu(I) and Fe(III)/Fe(II) should also significantly increase the sink function of the atmospheric liquid phase for HO 2 present in a cloud. A simple kinetic model for the reactions of Fe, Cu and HO 2/O 2-, accurately predicted the changes in Fe oxidation states that occurred when authentic fogwater samples were exposed to HO 2/O 2-.

  5. Analytical applications of condensed phosphoric acid-I Determination of ferrous and total iron in iron ores after decomposition with condensed phosphoric acid.

    Science.gov (United States)

    Mizoguchi, T; Ishii, H

    1978-06-01

    A simple method is described for the determination of ferrous and total iron in iron ores. Iron ores are dissolved by condensed phosphoric acid (CPA) very rapidly without any tedious and time-consuming manipulations such as elimination of silica and filtration. Under the proposed conditions (amount of sample 100 mg, amount of CPA added 10 g, heating temperature 290 degrees , heating time 30 min), magnetite, limonite and hematite are completely dissolved. The iron content can be determined in the presence of condensed phosphoric acid by titration with dichromate solution, if a slight modification is made. The total iron in iron ores, determined by the present method, is in agreement with that found by the JIS method. The ferrous iron in iron ores can be determined by dissolving the samples with CPA in a nitrogen atmosphere and titrating with dichromate solution. Chelatometric titration of iron after solvent extraction with MIBK from solutions prepared by use of CPA is found to be accurate for samples such as pyrite cinder. The ability of CPA to dissolve various materials has been investigated.

  6. Indoor Positioning Using GPS Revisited

    DEFF Research Database (Denmark)

    Kjærgaard, Mikkel Baun; Blunck, Henrik; Godsk, Torben

    2010-01-01

    It has been considered a fact that GPS performs too poorly inside buildings to provide usable indoor positioning. We analyze results of a measurement campaign to improve on the understanding of indoor GPS reception characteristics. The results show that using state-of-the-art receivers GPS...... low signal-to-noise ratios, multipath phenomena or bad satellite constellation geometry. We have also measured the indoor performance of embedded GPS receivers in mobile phones which provided lower availability and accuracy than state-of-the-art ones. Finally, we consider how the GPS performance...

  7. Indoor Semantic Modelling for Routing: The Two-Level Routing Approach for Indoor Navigation

    Directory of Open Access Journals (Sweden)

    Liu Liu

    2017-11-01

    Full Text Available Humans perform many activities indoors and they show a growing need for indoor navigation, especially in unfamiliar buildings such as airports, museums and hospitals. Complexity of such buildings poses many challenges for building managers and visitors. Indoor navigation services play an important role in supporting these indoor activities. Indoor navigation covers extensive topics such as: 1 indoor positioning and localization; 2 indoor space representation for navigation model generation; 3 indoor routing computation; 4 human wayfinding behaviours; and 5 indoor guidance (e.g., textual directories. So far, a large number of studies of pedestrian indoor navigation have presented diverse navigation models and routing algorithms/methods. However, the major challenge is rarely referred to: how to represent the complex indoor environment for pedestrians and conduct routing according to the different roles and sizes of users. Such complex buildings contain irregular shapes, large open spaces, complicated obstacles and different types of passages. A navigation model can be very complicated if the indoors are accurately represented. Although most research demonstrates feasible indoor navigation models and related routing methods in regular buildings, the focus is still on a general navigation model for pedestrians who are simplified as circles. In fact, pedestrians represent different sizes, motion abilities and preferences (e.g., described in user profiles, which should be reflected in navigation models and be considered for indoor routing (e.g., relevant Spaces of Interest and Points of Interest. In order to address this challenge, this thesis proposes an innovative indoor modelling and routing approach – two-level routing. It specially targets the case of routing in complex buildings for distinct users. The conceptual (first level uses general free indoor spaces: this is represented by the logical network whose nodes represent the spaces and edges

  8. Ocean fertilization with iron: effects on climate and air quality

    International Nuclear Information System (INIS)

    Liss, Peter; Chuck, Adele; Bakker, Dorothee; Turner, Suzanne

    2005-01-01

    It is well known that iron fertilization can increase primary production and hence CO 2 drawdown over a significant fraction of the oceans. What is less well established is the extent to which this leads to long-term sequestration of carbon to the deep oceans, and to feedbacks to the atmosphere arising from increased biological activity. In this note results for changes in trace gas concentrations during an iron addition experiment in the Southern Ocean are presented. They demonstrate that a complex situation exists; some gases (DMS, CH 3 I, CHBr 2 Cl) show increases in concentration following fertilization with iron while others show no change (CH 3 ONO 2 , CH 2 ClI) or even a decrease (CHBr 3 ). The concomitant effects on air/sea fluxes of these gases are potentially important for climate and atmospheric composition

  9. A Hybrid 3D Indoor Space Model

    Directory of Open Access Journals (Sweden)

    A. Jamali

    2016-10-01

    Full Text Available GIS integrates spatial information and spatial analysis. An important example of such integration is for emergency response which requires route planning inside and outside of a building. Route planning requires detailed information related to indoor and outdoor environment. Indoor navigation network models including Geometric Network Model (GNM, Navigable Space Model, sub-division model and regular-grid model lack indoor data sources and abstraction methods. In this paper, a hybrid indoor space model is proposed. In the proposed method, 3D modeling of indoor navigation network is based on surveying control points and it is less dependent on the 3D geometrical building model. This research proposes a method of indoor space modeling for the buildings which do not have proper 2D/3D geometrical models or they lack semantic or topological information. The proposed hybrid model consists of topological, geometrical and semantical space.

  10. Indoor Tanning Is Not Safe

    Science.gov (United States)

    ... the sun is by using these tips for skin cancer prevention. Indoor tanning is not a safe way to get vitamin ... to previous findings on the association between indoor tanning and skin cancer. Only a small number of people reported ...

  11. Measurement of the size distributions of radon progeny in indoor air

    International Nuclear Information System (INIS)

    Hopke, P.K.; Ramamurthi, M.; Li, C.S.

    1990-01-01

    A major problem in evaluating the health risk posed by airborne radon progeny in indoor atmospheres is the lack of available information on the activity-weighted size distributions that occur in the domestic environment. With an automated, semicontinuous, graded screen array system, we made a series of measurements of activity-weighted size distributions in several houses in the northeastern United States. Measurements were made in an unoccupied house, in which human aerosol-generating activities were simulated. The time evolution of the aerosol size distribution was measured in each situation. Results of these measurements are presented

  12. Climate change consequences for the indoor environment

    NARCIS (Netherlands)

    Ariës, M.B.C.; Bluyssen, P.M.

    2009-01-01

    Scientists warn us about climate change and its effects on the outdoor environment. These effects can have significant consequences for the indoor environment, also in the Netherlands. Climate changes will affect different aspects of the indoor environment as well as the stakeholders of that indoor

  13. Measurements of MIMO Indoor Channels at 1800 MHz with Multiple Indoor and Outdoor Base Stations

    Directory of Open Access Journals (Sweden)

    Jaldén Niklas

    2007-01-01

    Full Text Available This paper proposes several configurations for multiple base stations in indoor MIMO systems and compares their performance. The results are based on channel measurements realized with a MIMO testbed. The receiver was moved along several routes and floors on an office building. Both outdoor and indoor locations are considered for the transmitters or base stations, which allow the analysis of not only indoor but also outdoor-to-indoor environment. The use of 2 base stations with different system level combinations of the two is analyzed. We show that the configuration with base station selection provides almost as good performance as a full water-filling scheme when the 2 base stations are placed at different locations. Also the spatial correlation properties for the different configurations are analyzed and the importance of considering path loss when evaluating capacity is highlighted.

  14. Indoor combustion and asthma.

    Science.gov (United States)

    Belanger, Kathleen; Triche, Elizabeth W

    2008-08-01

    Indoor combustion produces both gases (eg, nitrogen dioxide, carbon monoxide) and particulate matter that may affect the development or exacerbation of asthma. Sources in the home include both heating devices (eg, fireplaces, woodstoves, kerosene heaters, flued [ie, vented] or nonflued gas heaters) and gas stoves for cooking. This article highlights the recent literature examining associations between exposure to indoor combustion and asthma development and severity. Since asthma is a chronic condition affecting both children and adults, both age groups are included in this article. Overall, there is some evidence of an association between exposure to indoor combustion and asthma, particularly asthma symptoms in children. Some sources of combustion such as coal stoves have been more consistently associated with these outcomes than other sources such as woodstoves.

  15. A survey of perfluoroalkyl sulfonamides in indoor and outdoor air using passive air samplers

    Energy Technology Data Exchange (ETDEWEB)

    Shoeib, M.; Harner, T. [Meteorological Service of Canada, Environment Canada (Canada); Wilford, B.; Jones, K. [Lancaster Univ. (United Kingdom). Environmental Science; Zhu, J. [Chemistry Research Division, Health Canada, Tunney' s Pasture, Ottawa (Canada)

    2004-09-15

    Perfluorooctane sulfonate (PFOS) has recently emerged as a priority environmental pollutant due to its widespread detection in biological samples from remote regions including the Arctic and the Mid-North Pacific Ocean. Because PFOS is fairly involatile, it is hypothesized that its occurrence in remote regions is the result of atmospheric transport of more volatile precursor compounds such as the perfluoroalkyl sulfonamides (PFASs). PFASs are used in variety of consumer products for water and oil resistance including surface treatments for fabric, upholstery, carpet, paper and leather. In a recent pilot study employing high volume air samples, indoor air concentrations of PFASs were approximately 100 times greater than outdoor levels. This is of significance because people typically spend about 90% of their time indoors 5 and this exposure may serve as an important uptake pathway. Indoor air also serves as a source of PFASs to the outside where PFASs are ultimately transported and distributed throughout the environment. The current study is intended to be a more comprehensive survey of indoor and outdoor air allowing more confident conclusions to be made. Passive air samplers comprised of polyurethane foam (PUF) disks were used. These are quiet, non-intrusive samplers that operate without the aid of a pump or electricity. Air movement delivers chemical to the sampler which has a high retention capacity for persistent organic pollutants (POPs). PUF disks samplers have been previously used successfully to monitor different classes of hydrophobic persistent organic pollutants POPs.

  16. Plants for Sustainable Improvement of Indoor Air Quality.

    Science.gov (United States)

    Brilli, Federico; Fares, Silvano; Ghirardo, Andrea; de Visser, Pieter; Calatayud, Vicent; Muñoz, Amalia; Annesi-Maesano, Isabella; Sebastiani, Federico; Alivernini, Alessandro; Varriale, Vincenzo; Menghini, Flavio

    2018-04-10

    Indoor pollution poses a serious threat to human health. Plants represent a sustainable but underexploited solution to enhance indoor air quality. However, the current selection of plants suitable for indoors fails to consider the physiological processes and mechanisms involved in phytoremediation. Therefore, the capacity of plants to remove indoor air pollutants through stomatal uptake (absorption) and non-stomatal deposition (adsorption) remains largely unknown. Moreover, the effects of the indoor plant-associated microbiome still need to be fully analyzed. Here, we discuss how a combination of the enhanced phytoremediation capacity of plants together with cutting-edge air-cleaning and smart sensor technologies can improve indoor life while reducing energy consumption. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Characterizing the source of radon indoors

    International Nuclear Information System (INIS)

    Nero, A.V.; Nazaroff, W.W.

    1983-09-01

    Average indoor radon concentrations range over more than two orders of magnitude, largely because of variability in the rate at which radon enters from building materials, soil, and water supplies. Determining the indoor source magnitude requires knowledge of the generation of radon in source materials, its movement within materials by diffusion and convection, and the means of its entry into buildings. This paper reviews the state of understanding of indoor radon sources and transport. Our understanding of generation rates in and movement through building materials is relatively complete and indicates that, except for materials with unusually high radionuclide contents, these sources can account for observed indoor radon concentrations only at the low end of the range observed. Our understanding of how radon enters buildings from surrounding soil is poorer, however recent experimental and theoretical studies suggest that soil may be the predominant source in many cases where the indoor radon concentration is high. 73 references, 3 figures, 1 table

  18. Indoor Air Quality in Brazilian Universities

    Directory of Open Access Journals (Sweden)

    Sonia R. Jurado

    2014-07-01

    Full Text Available This study evaluated the indoor air quality in Brazilian universities by comparing thirty air-conditioned (AC (n = 15 and naturally ventilated (NV (n = 15 classrooms. The parameters of interest were indoor carbon dioxide (CO2, temperature, relative humidity (RH, wind speed, viable mold, and airborne dust levels. The NV rooms had larger concentration of mold than the AC rooms (1001.30 ± 125.16 and 367.00 ± 88.13 cfu/m3, respectively. The average indoor airborne dust concentration exceeded the Brazilian standards (<80 µg/m3 in both NV and AC classrooms. The levels of CO2 in the AC rooms were significantly different from the NV rooms (1433.62 ± 252.80 and 520.12 ± 37.25 ppm, respectively. The indoor air quality in Brazilian university classrooms affects the health of students. Therefore, indoor air pollution needs to be considered as an important public health problem.

  19. Research review: Indoor air quality control techniques

    International Nuclear Information System (INIS)

    Fisk, W.J.

    1986-10-01

    Techniques for controlling the concentration of radon, formaldehyde, and combustion products in the indoor air are reviewed. The most effective techniques, which are generally based on limiting or reducing indoor pollutant source strengths, can decrease indoor pollutant concentrations by a factor of 3 to 10. Unless the initial ventilation rate is unusually low, it is difficult to reduce indoor pollutant concentrations more than approximately 50% by increasing the ventilation rate of an entire building. However, the efficiency of indoor pollutant control by ventilation can be enhanced through the use of local exhaust ventilation near concentrated sources of pollutants, by minimizing short circuiting of air from supply to exhaust when pollutant sources are dispersed and, in some situations, by promoting a displacement flow of air and pollutants toward the exhaust. Active air cleaning is also examined briefly. Filtration and electrostatic air cleaning for removal of particles from the indoor air are the most practical and effective currently available techniques of air cleaning. 49 refs., 7 figs

  20. Indoor air pollution: a public health perspective

    International Nuclear Information System (INIS)

    Spengler, J.D.; Sexton, K.

    1983-01-01

    Although official efforts to control air pollution have traditionally focused on outdoor air, it is now apparent that elevated contaminant concentrations are common inside some private and public buildings. Concerns about potential public health problems due to indoor air pollution are based on evidence that urban residents typically spend more than 90 percent of their time indoors, concentrations of some contaminants are higher indoors than outdoors, and for some pollutants personal exposures are not characterized adequately by outdoor measurements. Among the more important indoor contaminants associated with health or irritation effects are passive tobacco smoke, radon decay products, carbon monoxide, nitrogen dioxide, formaldehyde, asbestos fibers, microorganisms, and aeroallergens. Efforts to assess health risks associated with indoor air pollution are limited by insufficient information about the number of people exposed, the pattern and severity of exposures, and the health consequences of exposures. An overall strategy should be developed to investigate indoor exposures, health effects, control options, and public policy alternatives

  1. Indoor environment program. 1994 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Daisey, J.M.

    1995-04-01

    Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, and energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.

  2. Indoor environment program - 1995 annual report

    Energy Technology Data Exchange (ETDEWEB)

    Daisey, J.M.

    1996-06-01

    Buildings use approximately one-third of the energy consumed in the United States. The potential energy savings derived from reduced infiltration and ventilation in buildings are substantial, since energy use associated with conditioning and distributing ventilation air is about 5.5 EJ per year. However, since ventilation is the dominant mechanism for removing pollutants from indoor sources, reduction of ventilation can have adverse effects on indoor air quality, and on the health, comfort, and productivity of building occupants. The Indoor Environment Program in LBL`s Energy and Environment Division was established in 1977 to conduct integrated research on ventilation, indoor air quality, and energy use and efficiency in buildings for the purpose of reducing energy liabilities associated with airflows into, within, and out of buildings while maintaining or improving occupant health and comfort. The Program is part of LBL`s Center for Building Science. Research is conducted on building energy use and efficiency, ventilation and infiltration, and thermal distribution systems; on the nature, sources, transport, transformation, and deposition of indoor air pollutants; and on exposure and health risks associated with indoor air pollutants. Pollutants of particular interest include radon; volatile, semivolatile, and particulate organic compounds; and combustion emissions, including environmental tobacco smoke, CO, and NO{sub x}.

  3. Statistical treatment of bleaching kaolin by iron removal

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez H, R. A.; Legorreta G, F.; Hernandez C, L. E. [Universidad Autonoma del Estado de Hidalgo, Area Academica de Ciencias de la Tierra y Materiales, Carretera Pachuca-Tulancingo Km 4.5, Mineral de la Reforma, 42184 Hidalgo (Mexico); Martinez L, A., E-mail: angelitofox3@hotmail.com [Universidad Autonoma de Coahuila, Blvd. V. Carranza y Gonzalez Lobo s/n, 25280 Saltillo, Coahuila (Mexico)

    2013-07-01

    In the present study, oxalic acid was used as a leaching reagent to remove iron from a kaolin mineral. Statistical analysis was conducted to determine the most influential factors in the dissolution of iron from the kaolin mineral. Our goal was ferric iron solubilization and its reduction to ferrous iron to improve the iron removal in the acid medium. Leaching experiments were conducted at atmospheric pressure. A two-level factorial design of the type 2{sup 4} was utilized. The dependent variable was the percentage of dissolved iron, and the dependent variables in this study were acid concentration (0.35 and 0.50 M), temperature (75 C and 100 C), leaching time (2 and 4 h), and ph (1.5 and 2.5). An analysis of variance revealed that the effects of the factors temperature (b), ph (d), and the combined effects of temperature and time (b c) resulted in the maximum dissolution of iron of 88% at 100 C, giving a kaolin mineral with a whiteness index 93.50. For the mineralogical analysis the X-ray diffraction technique was used. (Author)

  4. Statistical treatment of bleaching kaolin by iron removal

    International Nuclear Information System (INIS)

    Hernandez H, R. A.; Legorreta G, F.; Hernandez C, L. E.; Martinez L, A.

    2013-01-01

    In the present study, oxalic acid was used as a leaching reagent to remove iron from a kaolin mineral. Statistical analysis was conducted to determine the most influential factors in the dissolution of iron from the kaolin mineral. Our goal was ferric iron solubilization and its reduction to ferrous iron to improve the iron removal in the acid medium. Leaching experiments were conducted at atmospheric pressure. A two-level factorial design of the type 2 4 was utilized. The dependent variable was the percentage of dissolved iron, and the dependent variables in this study were acid concentration (0.35 and 0.50 M), temperature (75 C and 100 C), leaching time (2 and 4 h), and ph (1.5 and 2.5). An analysis of variance revealed that the effects of the factors temperature (b), ph (d), and the combined effects of temperature and time (b c) resulted in the maximum dissolution of iron of 88% at 100 C, giving a kaolin mineral with a whiteness index 93.50. For the mineralogical analysis the X-ray diffraction technique was used. (Author)

  5. Office of radiation and indoor air: Program description

    International Nuclear Information System (INIS)

    1993-06-01

    The goal of the Environmental Protection Agency's (EPA) Office of Radiation and Indoor Air is to protect the public and the environment from exposures to radiation and indoor air pollutants. The Office develops protection criteria, standards, and policies and works with other programs within EPA and other agencies to control radiation and indoor air pollution exposures; provides technical assistance to states through EPA's regional offices and other agencies having radiation and indoor air protection programs; directs an environmental radiation monitoring program; responds to radiological emergencies; and evaluates and assesses the overall risk and impact of radiation and indoor air pollution. The Office is EPA's lead office for intra- and interagency activities coordinated through the Committee for Indoor Air Quality. It coordinates with and assists the Office of Enforcement in enforcement activities where EPA has jurisdiction. The Office disseminates information and works with state and local governments, industry and professional groups, and citizens to promote actions to reduce exposures to harmful levels of radiation and indoor air pollutants

  6. Evidence of interstitial microsegregation in iron obtained by ion microscopy

    International Nuclear Information System (INIS)

    Price, C.W.

    1984-01-01

    Segregation of impurity atoms to the strain fields of dislocations and the effective locking of the dislocations by the impurity atmospheres have been suggested earlier by others. The formation of interstitial atmospheres and their effect in iron was first treated mathematically by Cottrell and Bilby (Proc. Phys. Soc.; A62: 49(1949). Hirth and Lothe (Theory of Discolations, McGraw-Hill, New York (1968) reviewed more recent evidence of interstitial effects and theoretical treatments of interstitial dislocation interactions. This paper describes additional evidence of microsegregation of several interstitial elements in iron that were detected using secondary-ion mass spectroscopy (SIMS). 10 references, 2 figures

  7. In-plane user positioning indoors

    NARCIS (Netherlands)

    Jovanovic, N.; Özçelebi, T.; Lukkien, J.J.; Skoric, B.; Ignatenko, T.

    2014-01-01

    Indoor positioning is a service required by many smart environment applications for various purposes, such as activity classification, indoor navigation and context awareness. In this paper, we present a novel approach to the user positioning problem based on in-plane detection enabled by a set of

  8. Higher Fe{sup 2+}/total Fe ratio in iron doped phosphate glass melted by microwave heating

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Ashis K., E-mail: ashis@cgcri.res.in [CSIR-Central Glass and Ceramic Research Institute, 196 Raja S.C. Mullick Road, Kolkata 700032 (India); Sinha, Prasanta K. [CSIR-Central Glass and Ceramic Research Institute, 196 Raja S.C. Mullick Road, Kolkata 700032 (India); Das, Dipankar [UGC-DAE Consortium for Scientific Research, Kolkata 700098 (India); Guha, Chandan [Department of Chemical Engineering, Jadavpur University, Kolkata 700032 (India); Sen, Ranjan [CSIR-Central Glass and Ceramic Research Institute, 196 Raja S.C. Mullick Road, Kolkata 700032 (India)

    2015-03-15

    Highlights: • Iron doped phosphate glasses prepared using microwave heating and conventional heating under air and reducing atmosphere. • Presence of iron predominantly in the ferrous oxidation state in all the glasses. • Significant concentrations of iron in the ferrous oxidation state on both octahedral and tetrahedral sites in all the glasses. • Ratio of Fe{sup 2+} with total iron is found higher in microwave prepared glasses in comparison to conventional prepared glasses. - Abstract: Iron doped phosphate glasses containing P{sub 2}O{sub 5}–MgO–ZnO–B{sub 2}O{sub 3}–Al{sub 2}O{sub 3} were melted using conventional resistance heating and microwave heating in air and under reducing atmosphere. All the glasses were characterised by UV–Vis–NIR spectroscopy, Mössbauer spectroscopy, thermogravimetric analysis and wet colorimetry analysis. Mössbauer spectroscopy revealed presence of iron predominantly in the ferrous oxidation state on two different sites in all the glasses. The intensity of the ferrous absorption peaks in UV–Vis–NIR spectrum was found to be more in glasses prepared using microwave radiation compared to the glasses prepared in a resistance heating furnace. Thermogravimetric analysis showed increasing weight gain on heating under oxygen atmosphere for glass corroborating higher ratio of FeO/(FeO + Fe{sub 2}O{sub 3}) in glass melted by direct microwave heating. Wet chemical analysis also substantiated the finding of higher ratio Fe{sup +2}/ΣFe in microwave melted glasses. It was found that iron redox ratio was highest in the glasses prepared in a microwave furnace under reducing atmosphere.

  9. Psychosocial dimensions of solving an indoor air problem.

    Science.gov (United States)

    Lahtinen, Marjaana; Huuhtanen, Pekka; Kähkönen, Erkki; Reijula, Kari

    2002-03-01

    This investigation focuses on the psychological and social dimensions of managing and solving indoor air problems. The data were collected in nine workplaces by interviews (n = 85) and questionnaires (n = 375). Indoor air problems in office environments have traditionally utilized industrial hygiene or technical expertise. However, indoor air problems at workplaces are often more complex issues to solve. Technical questions are inter-related with the dynamics of the work community, and the cooperation and interaction skills of the parties involved in the solving process are also put to the test. In the present study, the interviewees were very critical of the process of solving the indoor air problem. The responsibility for coordinating the problem-managing process was generally considered vague, as were the roles and functions of the various parties. Communication problems occurred and rumors about the indoor air problem circulated widely. Conflicts were common, complicating the process in several ways. The research focused on examining different ways of managing and resolving an indoor air problem. In addition, reference material on the causal factors of the indoor air problem was also acquired. The study supported the hypothesis that psychosocial factors play a significant role in indoor air problems.

  10. Potential for ion-induced nucleation of volatile organic compounds by radon decay in indoor environments

    International Nuclear Information System (INIS)

    Daisey, J.M.

    1991-11-01

    There is considerable interest in the ''unattached'' fraction of radon progeny in indoor air because of its significance to the estimation of the risks of radon exposure. Because of its high mobility in air, the unattached fraction is more efficiently deposited in the respiratory tract. Variation in the diameter of the ''unattached'' fraction and in its diffusion coefficient can be due to clustering of other atmospheric species around the 218 PoO 2 + ion. The purpose of this study was to investigate the potential for the formation of clusters of vapor phase organic compounds, found in indoor air, around the 218 PoO 2 + ion and to determine which were most likely to form clusters. A secondary purpose was to provide a compilation of measurements of indoor organic compounds for future experiments and theoretical calculations by the radon research community. The classical charged liquid droplet theory (Thomson equation) was used to estimate the Gibbs free energy of ion-induced nucleation and to provide an indication of the indoor organic compounds most likely to undergo ion-induced nucleation. Forty-four volatile and semi-volatile organic compounds out of the more than 300 which have been reported in indoor air were investigated. Water vapor was included for comparison. The results indicate that there is a potential for the formation of clusters of organic compounds around the 218 PoO 2 + ion. The compounds with the greatest potential for cluster formation are the volatile oxidized hydrocarbons (e.g., n-butanol, phenol, hexanal, nonanal, benzaldehyde, the ketones and the acetates) and the semi-volatile organic compounds (pentachlorophenol, nicotine, chlordane, chlorpyrifos)

  11. Indoor Positioning System using Bluetooth

    OpenAIRE

    Sahil Puri

    2015-01-01

    This Paper on Bluetooth Indoor Positioning System is the intersection of Bluetooth Technology and Indoor Positioning Systems. Almost every smartphone today is Bluetooth enabled, making the use of the technology more flexible. We aim at using the RSSI value of Bluetooth signals to track the location of a device.

  12. Behaviour of iron and titanium species in cryolite-alumina melts

    OpenAIRE

    Jentoftsen, Trond Eirik

    2000-01-01

    The solubility of divalent iron oxide in cryolite-based melts was studied. Both electrochemical and chemical techniques were employed. To ensure that only divalent iron was present in solution, the melt was contained in an iron crucible under an atmosphere of argon. The experimental work included investigation of the solubility as a function of alumina concentration, temperature and cryolite ratio (CR = NaF/AlF3 molar ratio). The solubility at 1020 ºC was found to decrease from 4.17 wt% Fe in...

  13. Comparative biogeochemical behaviors of iron-55 and stable iron in the marine environment

    International Nuclear Information System (INIS)

    Weimer, W.C.; Langford, J.C.; Jenkins, C.E.

    1978-01-01

    Studies of atmospheric aerosols have demonstrated that much of the 55 Fe associated with the aerosol input to the oceans is present as either an amorphous or hydrous iron oxide or as very small particulate species attached to the surfaces of the large aerosol particles. By comparison, nearly all of the stable iron is bound in the mineral phase of aerosol particles. This difference in the chemical and physical forms of the radioactive and stable iron isotopes results in the 55 Fe being more biologically available than is the stable iron. This difference in availability is responsible for the transfer of a much higher specific activity 55 Fe to certain ocean organisms and man relative to the specific activity of the total aerosol or of sea water. This differential biological uptake of the radioactive element and its stable element counterpart points out that natural levels of stable elements in the marine environment may not effectively dilute radioelements or other stable elements of anthropogenic sources. The effectiveness of dilution by natural sources depends on the chemical and physical forms of the materials in both the source terms and the receiving environments. The large difference in specific activities of 55 Fe in aerosols and sea water relative to ocean organisms reflects the independent behaviors of 55 Fe and stable iron

  14. Results of atmospheric radon survey from the tenth Antarctica expedition, 1990-1991

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subba Ramu, M.C.; Nambi, K.S.V.

    1992-01-01

    Results of the measurement of atmospheric radon (Rn) levels carried out en route to and from Antarctica and indoor Rn daughter levels at Antarctica are presented in this paper. Grab sampling and integrated methods were used for the measurements. The atmospheric Rn levels are found to decrease steadily from 2400 mBq.m -3 at Goa to 40 mBq.m -3 at the equator. It is found to decrease further to 13 mBq.m -3 towards 70degS. At Maitree station (70degS, 11degE), it varied from 20 to 30 mBq.m -3 . Measured indoor Rn daughter levels (equilibrium equivalent concentration, EEC Rn ) at Maitree station varied from 1.7 Bq.m -3 to 21.3Bq.m -3 in various residential places of the Indian Station. Using ICRP dose conversion factor, the estimated effective dose equivalents range from 0.14 mSv/y to 1.8 mSv/y. (author). 8 refs., 2 tabs

  15. LADM and IndoorGML for Support of Indoor Space Identification

    Science.gov (United States)

    Zlatanova, S.; Van Oosterom, P. J. M.; Lee, J.; Li, K.-J.; Lemmen, C. H. J.

    2016-10-01

    Guidance and security in large public buildings such as airports, museums and shopping malls requires much more information that traditional 2D methods offer. Therefore 3D semantically-reach models have been actively investigated with the aim to gather knowledge about availability and accessibility of spaces. Spaces can be unavailable to specific users because of plenty of reasons: the 3D geometry of spaces (too low, too narrow), the properties of the objects to be guided to a specific part of the building (walking, driving, flying), the status of the indoor environment (e.g. crowded, limited light, under reconstruction), property regulations (private areas), security considerations and so on. However, such information is not explicitly avaible in the existing 3D semantically-reach models. IFC and CityGML are restricted to architectural building components and provide little to no means to describe such properties. IndoorGML has been designed to establish a generic approach for space identification allowing a space subdivision and automatic creation of a network for route computation. But currently it also represents only spaces as they are defined by the architectural layout of the building. The Land Administration Domain Model is currently the only available model to specify spaces on the basis of ownership and rights for use. In this paper we compare the principles of IndoorGML and LADM, investigate the approaches to define spaces and suggest options to the linking of the two types of spaces. We argue that LADM space subdivision on basis of properties and rights of use can be used to define to semantically and geometrically available and accessible spaces and therefore can enrich the IndoorGML concept.

  16. Influence of environmental factors on indoor radon concentration levels in the basement and ground floor of a building – A case study

    International Nuclear Information System (INIS)

    Xie, Dong; Liao, Maili; Kearfott, Kimberlee J.

    2015-01-01

    A series of experiments was conducted to measure indoor radon concentrations variations and observe any correlations with indoor and outdoor atmospheric parameters for over a period of one year. Indoor environmental parameters and radon concentrations were measured on an hourly basis in a two-story building both in a laboratory on the well-ventilated ground floor and in the basement below it which had negligible ventilation. The monthly average indoor radon concentration value of 29 ± 21 Bq m"−"3 in the laboratory was below the ICRP recommended limit of 200–300 Bq m"−"3. The monthly normalization factor for that location ranged from 0.5 to 2.0, while the seasonal normalization factor ranged from 0.78 to 2.0. In the unventilated basement, however, the average monthly indoor radon concentration was 1083 ± 6 Bq m"−"3 with little seasonal variation. The basement is only used for storage and thus the elevated radon concentration does not pose a serious health risk. The results indicated that indoor radon levels are higher in the autumn–winter season than in the spring–summer season. Analysis further showed that indoor radon concentrations negatively correlated with indoor humidity (correlation coefficient R = −0.14, p < 0.01), outdoor temperature (correlation coefficient R = −0.3, p < 0.01), outdoor dew point temperature (correlation coefficient R = −0.17, p < 0.01) and outdoor wind speeds (correlation coefficient R = −0.25, p < 0.05). Radon concentrations correlated positively with outdoor barometric pressure (correlation coefficient R = 0.35, p < 0.01), indoor–outdoor temperature difference (correlation coefficient R = 0.32, p < 0.05) and indoor–outdoor barometric pressure difference (correlation coefficient R = 0.67, p < 0.01). Indoor temperature, indoor barometric pressure and outdoor wind direction showed no clear correlations with indoor radon concentration. - Highlights: • Environmental variables and

  17. The new scanning iron lidar, current state and future developments

    Science.gov (United States)

    Lautenbach, J.; Höffner, J.; Menzel, P.; Keller, P.

    2005-08-01

    This paper gives an update on the design and developments of the new scanning Doppler iron temperature lidar. Continuous temperature profiles in the altitude range from 50 to 105 km are derived by using the iron resonance and Rayleigh backscatter signal of this lidar. We show a common volume measurement with the well established potassium and Rayleigh-Mie-Raman (RMR) lidar at the Leibniz-Institute of Atmospheric Physics (IAP) in Kühlungsborn (Germany, 54°N). The iron lidar temperatures match quite well and have an uncertainty of 0.4K at the top of the iron layer. Improvements for daylight capability are under development and will be pointed out.

  18. Microenvironmental air and soil monitoring of contaminants: An evaluation of indoor and outdoor levels in Chihuahua City

    Science.gov (United States)

    Delgado-Rios, Marcos

    Like most of the cities around the world Chihuahua City suffers atmospheric and soil pollution. This is a problem that requires immediate attention from both public authorities and the scientific community. Although it is known that high levels of heavy metals are present in the airborne particulate matter, soil and dust in many urban regions, the information about personal exposure to these pollutants in Chihuahua City is nonexistent. This study focuses on the analysis and characterization of lead and arsenic in the airborne and soil particulate matter present in the interiors of households and their surrounding outdoor environments in the southern part of Chihuahua City. The sampling area chosen for this study was located in the southern part of Chihuahua City. An atmospheric sampling point selected by the Centro de Investigacion en Materiales Avanzados (CIMAV) was selected as a geographical center, with a 2 km radius forming the sampling area. The households selected for analyses were located on Lombardo Toledano Street, a high-traffic street. The main objectives of this study were to establish the maximum exposure level in outdoor and indoor environments for particulate matter less than 10 mum (PM 10), Pb, and As, to determine the background level of Chihuahua City for these same elements, to determine the isotopic ratios of Pb206 and Pb207 in the indoor and outdoor atmospheric samples, and to verify if the source of the pollution is from anthropogenic and/or natural sources. Additionally, a comparison of the analytical data from X-ray fluorescence (XRF) versus the analytical data from inductively coupled plasma with optical emission spectroscopy (ICP-OES) was conducted. The comparison of these techniques was based on sample preparation, speed of analysis, and accuracy of results. In the case of sample preparation, two extraction techniques were performed for a comparison of the extraction/leaching of Pb and As from the samples. These microwave

  19. Pilot study on indoor air quality: Managing indoor air-quality risks. Report on a meeting held in St. Michaels, Maryland on October 25-27, 1989

    International Nuclear Information System (INIS)

    1990-06-01

    Included in this study are the following: quantifying future trends of indoor air quality as a basis for government policy plans; assessing indoor air quality risks of pesticides; formaldehyde emission standards in the Federal Republic of Germany; orientations and actions of the European Community in the assessment and prevention of indoor air pollution; EPA and indoor air quality; the non-regulatory approach to reducing risks from radon exposure; U.S. consumer product safety commission; a builders guide to healthy homes; WHO air quality guidelines for Europe; the approach to control indoor air quality in Italy; guidelines - ventilation classes; energy consequences of upgrading indoor air quality; Canada's guidelines for residential indoor air quality: rationale and scope; Canadian ventilation and venting standards; indoor air quality building surveys case studies; design of indoor air quality studies; summary findings of inter-ministerial committee on indoor air quality (Ontario); the Quebec approach; employee survey EPA headquarters; pollution in closed spaces and its consequences in conservation of works of art; and how Norwegian health authorities will handle indoor air quality problems

  20. Recognition, evaluation, and control of indoor air pollution

    International Nuclear Information System (INIS)

    Chastain, B.

    1993-01-01

    Indoor air pollution is typically associated with terms sick building syndrome, tight building syndrome, building related illness, and problem building. Indoor air pollution is a relatively new public health concern (approximately 15 years old) although this issue is an age-old problem dating back to prehistoric times when humans came to live indoors. This presentation summarizes indoor air quality issues in order to provide you with usable information concerning the recognition and evaluation of indoor air quality (IAQ) problems and the subsequent control measures which can be used for maintaining or improving the indoor air environment for better occupant health and comfort control. Why has the subject become so vocalized in the last fifteen years? Why the sudden interest and awareness concerning indoor air quality issues? During the last half of the 1970's and all of the 1980's, buildings were built or remodeled to minimize air handling, heating, and cooling costs, often limiting the amount of outside air brought into the buildings to near minimums. Paralleling these developments, complaints related to modern buildings increased. The new terms tight building syndrome, sick building syndrome, and indoor air quality became widely used by health and safety professionals and subsequently by newspaper columnist and the general public

  1. Providing better indoor environmental quality brings economicbenefits

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William; Seppanen, Olli

    2007-06-01

    This paper summarizes the current scientific evidence that improved indoor environmental quality can improve work performance and health. The review indicates that work and school work performance is affected by indoor temperature and ventilation rate. Pollutant source removal can sometimes improve work performance. Based on formal statistical analyses of existing research results, quantitative relationships are provided for the linkages of work performance with indoor temperature and outdoor air ventilation rate. The review also indicates that improved health and related financial savings are obtainable from reduced indoor tobacco smoking, prevention and remediation of building dampness, and increased ventilation. Example cost-benefit analyses indicate that many measures to improve indoor temperature control and increase ventilation rates will be highly cost effective, with benefit-cost ratios as high as 80 and annual economic benefits as high as $700 per person.

  2. Indoor air quality environmental information handbook: Combustion sources

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    This environmental information handbook was prepared to assist both the non-technical reader (i.e., homeowner) and technical persons (such as researchers, policy analysts, and builders/designers) in understanding the current state of knowledge regarding combustion sources of indoor air pollution. Quantitative and descriptive data addressing the emissions, indoor concentrations, factors influencing indoor concentrations, and health effects of combustion-generated pollutants are provided. In addition, a review of the models, controls, and standards applicable to indoor air pollution from combustion sources is presented. The emphasis is on the residential environment. The data presented here have been compiled from government and privately-funded research results, conference proceedings, technical journals, and recent publications. It is intended to provide the technical reader with a comprehensive overview and reference source on the major indoor air quality aspects relating to indoor combustion activities, including tobacco smoking. In addition, techniques for determining potential concentrations of pollutants in residential settings are presented. This is an update of a 1985 study documenting the state of knowledge of combustion-generated pollutants in the indoor environment. 191 refs., 51 figs., 71 tabs.

  3. A Foundation for Efficient Indoor Distance-Aware Query Processing

    DEFF Research Database (Denmark)

    Lu, Hua; Cao, Xin; Jensen, Christian Søndergaard

    2012-01-01

    model that integrates indoor distance seamlessly. To enable the use of the model as a foundation for query processing, we develop accompanying, efficient algorithms that compute indoor distances for different indoor entities like doors as well as locations. We also propose an indexing framework......Indoor spaces accommodate large numbers of spatial objects, e.g., points of interest (POIs), and moving populations. A variety of services, e.g., location-based services and security control, are relevant to indoor spaces. Such services can be improved substantially if they are capable of utilizing...... that accommodates indoor distances that are pre-computed using the proposed algorithms. On top of this foundation, we develop efficient algorithms for typical indoor, distance-aware queries. The results of an extensive experimental evaluation demonstrate the efficacy of the proposals....

  4. Fungal pollution of indoor environments and its management.

    Science.gov (United States)

    Haleem Khan, A A; Mohan Karuppayil, S

    2012-10-01

    Indoor environments play important roles in human health. The health hazards posed by polluted indoor environments include allergy, infections and toxicity. Life style changes have resulted in a shift from open air environments to air tight, energy efficient, environments, in which people spend a substantial portion of their time. Most indoor air pollution comes from the hazardous non biological agents and biological agents. Fungi are ubiquitous in distribution and are a serious threat to public health in indoor environments. In this communication, we have reviewed the current status on biotic indoor air pollution, role of fungi as biological contaminants and their impact on human health.

  5. Air Quality and Indoor Environmental Exposures: Clinical ...

    Science.gov (United States)

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more polluted than ambient air, the USEPA lists poor IAQ as a major environmental concern. In the sections that follow, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. In some cases, exposure may be acute, with one or more pets (and owners) experiencing signs within a relatively short period. However, most exposures are episodic or chronic, making it difficult to definitively link poor IAQ to respiratory or other adverse health outcomes. Age or underlying immunologic, cardiac, or respiratory disease may further complicate the clinical picture, as those patients may be more sensitive to (and affected by) lower concentrations than prove problematic for healthy housemates. Because pets, like their owners, spend most of their lives indoors, we will discuss how certain home conditions can worsen indoor air quality and will briefly discuss measures to improve IAQ for owners and their pets. In this overview presentation, health effects associated with commonly encountered ambient air pollutants and indoor contaminants will be broken down by agent class. Because pets, like their owners, spend most of their lives indoo

  6. Iron isotope fractionation during pyrite formation in a sulfidic Precambrian ocean analogue

    Science.gov (United States)

    Rolison, John M.; Stirling, Claudine H.; Middag, Rob; Gault-Ringold, Melanie; George, Ejin; Rijkenberg, Micha J. A.

    2018-04-01

    The chemical response of the Precambrian oceans to rising atmospheric O2 levels remains controversial. The iron isotope signature of sedimentary pyrite is widely used to trace the microbial and redox states of the ocean, yet the iron isotope fractionation accompanying pyrite formation in nature is difficult to constrain due to the complexity of the pyrite formation process, difficulties in translating the iron isotope systematics of experimental studies to natural settings, and insufficient iron isotope datasets for natural euxinic (i.e. anoxic and sulfidic) marine basins where pyrite formation occurs. Herein we demonstrate, that a large, permil-level shift in the isotope composition of dissolved iron occurs in the Black Sea euxinic water column during syngenetic pyrite formation. Specifically, iron removal to syngenetic pyrite gives rise to an iron isotope fractionation factor between Fe(II) and FeS2 of 2.75 permil (‰), the largest yet reported for reactions under natural conditions that do not involve iron redox chemistry. These iron isotope systematics offer the potential to generate permil-level shifts in the sedimentary pyrite iron isotope record due to partial drawdown of the oceanic iron inventory. The implication is that the iron stable isotope signatures of sedimentary pyrites may record fundamental regime shifts between pyrite formation under sulfur-limited conditions and pyrite formation under iron-limited conditions. To this end, the iron isotope signatures of sedimentary pyrite may best represent the extent of euxinia in the past global ocean, rather than its oxygenation state. On this basis, the reinterpreted sedimentary pyrite Fe isotope record suggests a fundamental shift towards more sulfidic oceanic conditions coincident with the 'Great Oxidation Event' around 2.3 billion years ago. Importantly, this does not require the chemical state of the ocean to shift from mainly de-oxygenated to predominantly oxygenated in parallel with the permanent rise

  7. Simulating Real-World Exposures during Emergency Events: Studying Effects of Indoor and Outdoor Releases in the Urban Dispersion Project in Upper Manhattan, NY

    Science.gov (United States)

    A prospective personal exposure study, involving indoor and outdoor releases, was conducted in upper Midtown Manhattan in New York City as part of the Urban Dispersion Program (UDP) focusing on atmospheric dispersion of chemicals in complex urban settings. The UDP experiments inv...

  8. Plants for Sustainable Improvement of Indoor Air Quality

    NARCIS (Netherlands)

    Brilli, Federico; Fares, Silvano; Ghirardo, Andrea; Visser, de Pieter; Calatayud, Vicent; Muñoz, Amalia; Annesi-Maesano, Isabella; Sebastiani, Federico; Alivernini, Alessandro; Varriale, Vincenzo; Menghini, Flavio

    2018-01-01

    Indoor pollution poses a serious threat to human health. Plants represent a sustainable but underexploited solution to enhance indoor air quality. However, the current selection of plants suitable for indoors fails to consider the physiological processes and mechanisms involved in phytoremediation.

  9. Supporting Indoor Navigation Using Access Rights to Spaces Based on Combined Use of IndoorGML and LADM Models

    Directory of Open Access Journals (Sweden)

    Abdullah Alattas

    2017-11-01

    Full Text Available The aim of this research is to investigate the combined use of IndoorGML and the Land Administration Domain Model (LADM to define the accessibility of the indoor spaces based on the ownership and/or the functional right for use. The users of the indoor spaces create a relationship with the space depending on the type of the building and the function of the spaces. The indoor spaces of each building have different usage functions and associated users. By defining the user types of the indoor spaces, LADM makes it possible to establish a relationship between the indoor spaces and the users. LADM assigns rights, restrictions, and responsibilities to each indoor space, which indicates the accessible spaces for each type of user. The three-dimensional (3D geometry of the building will be impacted by assigning such functional rights, and will provide additional knowledge to path computation for an individual or a group of users. As a result, the navigation process will be more appropriate and simpler because the navigation path will avoid all of the non-accessible spaces based on the rights of the party. The combined use of IndoorGML and LADM covers a broad range of information classes: (indoor 3D cell spaces, connectivity, spatial units/boundaries, (access/use rights and restrictions, parties/persons/actors, and groups of them. The new specialized classes for individual students, individual staff members, groups of students, groups of staff members are able to represent cohorts of education programmes and the organizational structure (organogram: faculty, department, group. The model is capable to represent the access times to lecture rooms (based on education/teaching schedules, use rights of meeting rooms, opening hours of offices, etc. The two original standard models remain independent in our approach, we do not propose yet another model, but applications can fully benefit of the potential of the combined use, which is an important contribution

  10. Measurements of the deposition rates of radon daughters on indoor surfaces

    International Nuclear Information System (INIS)

    Wang, H.; Essling, M.A.; Toohey, R.E.; Rundo, J.

    1982-01-01

    The deposition rates of radon daughters on indoor surfaces have been measured by exposing the window of a proportional counter to the air of a house with high concentrations of radon and its daughters. Deposition velocities for unattached 218 Po (RaA) and 214 Pb (RaB) of approximately 4 mm sec - 1 were obtained by dividing the deposition rates by the concentrations of unattached daughters in the air. These results agree with those obtained by other workers but are dependent on the assumptions made about the fractions of the daughters which are attached to the atmospheric aerosol

  11. Indoor Photography

    OpenAIRE

    Sagers, Stephen; Patterson, Ron

    2011-01-01

    Photography is the science of recording light in an artistic way to create a pleasing image. Indoor photography requires a photographer to become familiar with some of the built in functions of a camera.

  12. Outdoor-indoor air pollution in urban environment: Challenges and opportunity

    Directory of Open Access Journals (Sweden)

    Dennis Y.C. eLeung

    2015-01-01

    Full Text Available With the continual improvement in our quality of life, indoor air quality has become an important area of concern in the 21st century. Indoor air quality is affected by many factors including the type and running conditions of indoor pollution sources, ventilation conditions, as well as indoor activities. Studies revealed that the outdoor environment is also an important factor that cannot be neglected for indoor air quality studies. In this review, the indoor and outdoor air pollution relationships obtained from different studies are discussed in order to identify the key factors affecting the indoor air quality. As climate change is recognized as imposing impacts on the environment, how it affects the indoor air quality and the health impacts to the occupants will be evaluated in this paper. The major challenges and opportunities in indoor/outdoor air pollution studies will be highlighted.

  13. Scopulariopsis and scopulariopsis-like species from indoor environments

    Directory of Open Access Journals (Sweden)

    J.H.C. Woudenberg

    2017-09-01

    Full Text Available Scopulariopsis-like species are often reported from the indoor environment, as well as from clinical samples. The lack of type isolates and thorough phylogenetic studies in the Microascaceae hampered the correct identification of these isolates. Based on recent phylogenetic studies, which resulted in multiple name changes, the aim is to molecularly identify the Scopulariopsis and scopulariopsis-like species which occur in the indoor environment and give an overview of the current species in these genera and their habitats. Strains from the CBS culture collection were supplemented with almost 80 indoor strains of which the internal transcribed spacer 1 and 2 and intervening 5.8S nrDNA (ITS, beta-tubulin (tub2 and translation elongation factor 1-alpha (tef1 gene regions were sequenced for phylogenetic inference. The multi-gene phylogenies recognise 33 Microascus species and 12 Scopulariopsis species and showed that the recently established genus Fuscoannellis, typified by Scopulariopsis carbonaria, should be synonymized with the genus Yunnania. Seven new Microascus species, four new Scopulariopsis species, and one new Yunnania species, are described, and a new name in Microascus and two new name combinations (one in Microascus, and one in Yunnania are proposed. In the indoor environment 14 Microascus species and three Scopulariopsis species were found. Scopulariopsis brevicaulis (22 indoor isolates and Microascus melanosporus (19 indoor isolates are the most common indoor species, in number of isolates, followed by M. paisii (8 indoor isolates and S. candida (7 indoor isolates. A genus phylogeny based on the ITS, tef1 and the large subunit 28S nrDNA (LSU of the type or representative isolates of all here recognised species is provided depicting all species habitats. No correlation between phylogenetic relationship and habitat preference could be observed. Ten species which are found indoor are also found in relation with human-derived samples. A

  14. Evolution of Indoor Positioning Technologies: A Survey

    Directory of Open Access Journals (Sweden)

    Ramon F. Brena

    2017-01-01

    Full Text Available Indoor positioning systems (IPS use sensors and communication technologies to locate objects in indoor environments. IPS are attracting scientific and enterprise interest because there is a big market opportunity for applying these technologies. There are many previous surveys on indoor positioning systems; however, most of them lack a solid classification scheme that would structurally map a wide field such as IPS, or omit several key technologies or have a limited perspective; finally, surveys rapidly become obsolete in an area as dynamic as IPS. The goal of this paper is to provide a technological perspective of indoor positioning systems, comprising a wide range of technologies and approaches. Further, we classify the existing approaches in a structure in order to guide the review and discussion of the different approaches. Finally, we present a comparison of indoor positioning approaches and present the evolution and trends that we foresee.

  15. THE EXTRACTION OF INDOOR BUILDING INFORMATION FROM BIM TO OGC INDOORGML

    Directory of Open Access Journals (Sweden)

    T.-A. Teo

    2017-07-01

    Full Text Available Indoor Spatial Data Infrastructure (indoor-SDI is an important SDI for geosptial analysis and location-based services. Building Information Model (BIM has high degree of details in geometric and semantic information for building. This study proposed direct conversion schemes to extract indoor building information from BIM to OGC IndoorGML. The major steps of the research include (1 topological conversion from building model into indoor network model; and (2 generation of IndoorGML. The topological conversion is a major process of generating and mapping nodes and edges from IFC to indoorGML. Node represents every space (e.g. IfcSpace and objects (e.g. IfcDoor in the building while edge shows the relationships between nodes. According to the definition of IndoorGML, the topological model in the dual space is also represented as a set of nodes and edges. These definitions of IndoorGML are the same as in the indoor network. Therefore, we can extract the necessary data in the indoor network and easily convert them into IndoorGML based on IndoorGML Schema. The experiment utilized a real BIM model to examine the proposed method. The experimental results indicated that the 3D indoor model (i.e. IndoorGML model can be automatically imported from IFC model by the proposed procedure. In addition, the geometric and attribute of building elements are completely and correctly converted from BIM to indoor-SDI.

  16. Preventing Skin Cancer Through Reduction of Indoor Tanning

    Science.gov (United States)

    Watson, Meg; Holman, Dawn M.; Fox, Kathleen A.; Guy, Gery P.; Seidenberg, Andrew B.; Sampson, Blake P.; Sinclair, Craig; Lazovich, DeAnn

    2015-01-01

    Exposure to ultraviolet radiation from indoor tanning devices (tanning beds, booths, and sun lamps) or from the sun contributes to the risk of skin cancer, including melanoma, which is the type of skin cancer responsible for most deaths. Indoor tanning is common among certain groups, especially among older adolescents and young adults, adolescent girls and young women, and non-Hispanic whites. Increased understanding of the health risks associated with indoor tanning has led to many efforts to reduce use. Most environmental and systems efforts in the U.S. (e.g., age limits or requiring parental consent/accompaniment) have occurred at the state level. At the national level, the U.S. Food and Drug Administration and the Federal Trade Commission regulate indoor tanning devices and advertising, respectively. The current paper provides a brief review of (1) the evidence on indoor tanning as a risk factor for skin cancer; (2) factors that may influence use of indoor tanning devices at the population level; and (3) various environmental and systems options available for consideration when developing strategies to reduce indoor tanning. This information provides the context and background for the companion paper in this issue of the American Journal of Preventive Medicine, which summarizes highlights from an informal expert meeting convened by the CDC in August 2012 to identify opportunities to prevent skin cancer by reducing use of indoor tanning devices. PMID:23683987

  17. Characterization of the end products of the hydrolysis of iron in aqueous solution

    International Nuclear Information System (INIS)

    Jaen, J.A.; Acevedo, E.; Gonzalez, M.

    1994-01-01

    A characterization of the iron phases precipitated from aerated solutions of iron(II) sulfate heptahydrate was made using Moessbauer spectroscopy. The experimental conditions for the preparation of the samples were varied. The results are used to the further understanding of rust formation during atmospheric corrosion. (orig.)

  18. Design an Indoor Air Quality Controller Based on LPC2478

    Directory of Open Access Journals (Sweden)

    Shi Shuheng

    2014-07-01

    Full Text Available Indoor air quality is very important to our lives, because we spend most of our time indoor. In order to improve the air quality of indoor, this paper designs an indoor environment quality monitoring and controlling system based on ARM microcontroller LPC2478. It will do a real-time monitoring work for detecting the indoor environmental factors and comprehensively evaluate its air quality level. While the indoor air quality status is "poor", this intelligent system will automatically start the heat exchange ventilator for indoor environmental quality improvement. The results compared to traditional natural ventilation method show the better performance of proposed system.

  19. Designing Indoor Climate. A Thesis on the Integration of Indoor Climate Analysis in Architectural Design

    Energy Technology Data Exchange (ETDEWEB)

    Den Hartog, J.P.

    2003-12-01

    In contemporary architecture education, indoor climate and building installations suffer from a lack of popularity. Students of architecture, filled with great expectations and awe for the famous designers of the 20th century, find inspiration in examples such as Le Corbusier's Villa Savoy, Lloyd Wright's falling water or the Rietveld's Schroder house. Recognizable as this may be, great aesthetics constitute only a small part of creating architecture. The process of designing and constructing buildings comprises the involvement of a multitude of skills such as creating clear functional layouts, designing solid structures and taking care of healthy indoor climates. Most textbooks and magazines contemporary architecture do not cover the less attractive aspects of the indoor climate such as heating, ventilation and cooling unless these services form an important part of the buildings aesthetic identity. Recent examples regarding the integration of second skin facades and natural ventilation in indoor climate, sometimes fail to convince as a result of the lack of thorough evaluations and detailed information.

  20. Influence of indoor formaldehyde pollution on respiratory system ...

    African Journals Online (AJOL)

    Background The decoration of interior spaces can lead to dangerous levels of indoor formaldehyde pollution. Exposure to indoor air pollution may be responsible for nearly 2 million deaths per year in developing countries. Objectives To assess the prevalence of indoor formaldehyde pollution caused by decoration and ...

  1. Air Quality and Indoor Environmental Exposures: Clinical Impacts

    Science.gov (United States)

    Indoor air quality (IAQ) is a term which refers to the air quality within and around buildings and homes as it relates to the health and comfort of the occupants. Many ambient (outdoor) air pollutants readily permeate indoor spaces. Because indoor air can be considerably more pol...

  2. Estimation of exposure to atmospheric pollutants during pregnancy integrating space-time activity and indoor air levels: does it make a difference?

    Science.gov (United States)

    Marion, OUIDIR; Lise, GIORGIS-ALLEMAND; Sarah, LYON-CAEN; Xavier, MORELLI; Claire, CRACOWSKI; Sabrina, PONTET; Isabelle, PIN; Johanna, LEPEULE; Valérie, SIROUX; Rémy, SLAMA

    2016-01-01

    Studies of air pollution effects during pregnancy generally only consider exposure in the outdoor air at the home address. We aimed to compare exposure models differing in their ability to account for the spatial resolution of pollutants, space-time activity and indoor air pollution levels. We recruited 40 pregnant women in the Grenoble urban area, France, who carried a Global Positioning System (GPS) during up to 3 weeks; in a subgroup, indoor measurements of fine particles (PM2.5) were conducted at home (n=9) and personal exposure to nitrogen dioxide (NO2) was assessed using passive air samplers (n=10). Outdoor concentrations of NO2, and PM2.5 were estimated from a dispersion model with a fine spatial resolution. Women spent on average 16 h per day at home. Considering only outdoor levels, for estimates at the home address, the correlation between the estimate using the nearest background air monitoring station and the estimate from the dispersion model was high (r=0.93) for PM2.5 and moderate (r=0.67) for NO2. The model incorporating clean GPS data was less correlated with the estimate relying on raw GPS data (r=0.77) than the model ignoring space-time activity (r=0.93). PM2.5 outdoor levels were not to moderately correlated with estimates from the model incorporating indoor measurements and space-time activity (r=−0.10 to 0.47), while NO2 personal levels were not correlated with outdoor levels (r=−0.42 to 0.03). In this urban area, accounting for space-time activity little influenced exposure estimates; in a subgroup of subjects (n=9), incorporating indoor pollution levels seemed to strongly modify them. PMID:26300245

  3. [Schools, office buildings, leisure settings: diversity of indoor air quality issues. Global review on indoor air quality in these settings].

    Science.gov (United States)

    Mandin, C; Derbez, M; Kirchner, S

    2012-07-01

    This review provides a global overview of indoor air quality issues in schools, office buildings and recreational settings. It presents the most recent scientific publications and the on-going work conducted in France in the frame of the indoor air quality Observatory. Monitoring campaigns on indoor air quality in schools have been carried out in the recent years in Europe. However, few studies have specifically addressed the role of exposure in these buildings on children's health. Indoor air quality in office buildings has been little studied so far. However, some specificities, such as emissions from electronic devices, frequent cleaning, impossibility to open windows in high-rise buildings, for example, should be examined and their role on the health and comfort studied. Finally, even if the time spent in recreational settings is short, the quality of indoor air should also be considered because of specific pollution. This is the case of indoor swimming pools (exposure to chlorination byproducts) and ice-rinks (exposure to exhaust from machines used to smooth the ice). Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  4. Climate change and health: Indoor heat exposure in vulnerable populations

    International Nuclear Information System (INIS)

    White-Newsome, Jalonne L.; Sánchez, Brisa N.; Jolliet, Olivier; Zhang, Zhenzhen; Parker, Edith A.; Timothy Dvonch, J.; O'Neill, Marie S.

    2012-01-01

    Introduction: Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods: We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 in Detroit, MI. We used mixed linear regression to model indoor temperatures' responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results: Average maximum indoor temperature for all locations was 34.85 °C, 13.8 °C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions: Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings to improve heat exposure assessment for epidemiological investigations. Weatherizing homes and modifying home surroundings could mitigate indoor heat exposure among the elderly.

  5. Usability analysis of indoor map application in a shopping centre

    Science.gov (United States)

    Dewi, R. S.; Hadi, R. K.

    2018-04-01

    Although indoor navigation is still new in Indonesia, its future development is very promising. Similar to the outdoor one, the indoor navigation technology provides several important functions to support route and landmark findings. Furthermore, there is also a need that indoor navigation can support the public safety especially during disaster evacuation process in a building. It is a common that the indoor navigation technologies are built as applications where users can access this technology using their smartphones, tablets, or personal computers. Therefore, a usability analysis is important to ensure the indoor navigation applications can be operated by users with highest functionality. Among several indoor map applications which were available in the market, this study chose to analyse indoor Google Maps due to its availability and popularity in Indonesia. The experiments to test indoor Google Maps was conducted in one of the biggest shopping centre building in Surabaya, Indonesia. The usability was measured by employing System Usability Scale (SUS) questionnaire. The result showed that the SUS score of indoor Google Maps was below the average score of other cellular applications to indicate the users still had high difficulty in operating and learning the features of indoor Google Maps.

  6. An architectural framework for 5G indoor communications

    NARCIS (Netherlands)

    Chandra, Kishor; Prasad, R. Venkatesha; Niemegeers, Ignas

    2015-01-01

    In this paper, we emphasize on indoor networks in 5G era. We explore the possible technologies and architectural solutions for 5G indoor communications. Owing to the fact that requirements for indoor and outdoor communications will be quite different in the next generation networks, we try to define

  7. The Comfort Houses : measurements and analysis of the indoor environment and energy consumption in 8 passive houses 2008-2011

    Energy Technology Data Exchange (ETDEWEB)

    Steen Larsen, T.; Lund Jensen, R.; Daniels, O.

    2012-01-15

    The report is prepared in relation to the project ''demonstration of energy consumption and indoor climate in 10 Danish passive houses'' which was carried out from 2008 to 2012 in the Comfort Houses. The report presents the achieved results based on measurements of indoor climate and energy consumption, and it also suggests viable solutions for the future low-energy buildings. The Comfort House project was started in 2007 as a development project at the company Saint Gobain Isover A/S, who wanted to disseminate knowledge about low-energy buildings and the principles behind them. The present report mainly focuses on the results from the Comfort Houses, but it also includes references to other Danish experimental buildings and development projects. Furthermore, the analyses are supplemented with experiences from Swedish low-energy buildings found through literature reviews. The indoor climate analyses deal with the different physical parameters that impact the residents. The evaluation includes both thermal, atmospheric, daylight and acoustic climate. The energy consumption is evaluated together with some of the key parameters from the houses that are related to the energy consumption. Finally, the residents' behaviour impacting both energy consumption and indoor climate are analysed. (LN)

  8. Indoor radon and earthquake

    International Nuclear Information System (INIS)

    Saghatelyan, E.; Petrosyan, L.; Aghbalyan, Yu.; Baburyan, M.; Araratyan, L.

    2004-01-01

    For the first time on the basis of the Spitak earthquake of December 1988 (Armenia, December 1988) experience it is found out that the earthquake causes intensive and prolonged radon splashes which, rapidly dispersing in the open space of close-to-earth atmosphere, are contrastingly displayed in covered premises (dwellings, schools, kindergartens) even if they are at considerable distance from the earthquake epicenter, and this multiplies the radiation influence on the population. The interval of splashes includes the period from the first fore-shock to the last after-shock, i.e. several months. The area affected by radiation is larger vs. Armenia's territory. The scale of this impact on population is 12 times higher than the number of people injured in Spitak, Leninakan and other settlements (toll of injured - 25 000 people, radiation-induced diseases in people - over 300 000). The influence of radiation directly correlates with the earthquake force. Such a conclusion is underpinned by indoor radon monitoring data for Yerevan since 1987 (120 km from epicenter) 5450 measurements and multivariate analysis with identification of cause-and-effect linkages between geo dynamics of indoor radon under stable and conditions of Earth crust, behavior of radon in different geological mediums during earthquakes, levels of room radon concentrations and effective equivalent dose of radiation impact of radiation dose on health and statistical data on public health provided by the Ministry of Health. The following hitherto unexplained facts can be considered as consequences of prolonged radiation influence on human organism: long-lasting state of apathy and indifference typical of the population of Armenia during the period of more than a year after the earthquake, prevalence of malignant cancer forms in disaster zones, dominating lung cancer and so on. All urban territories of seismically active regions are exposed to the threat of natural earthquake-provoked radiation influence

  9. Parent's Guide to School Indoor Air Quality. Revised

    Science.gov (United States)

    Healthy Schools Network, Inc., 2012

    2012-01-01

    Air pollution is air pollution, indoors or out. Good indoor air quality (IAQ) contributes to a favorable learning environment for students, protects health, and supports the productivity of school personnel. In schools in poor repair, leaky roofs and crumbling walls have caused additional indoor air quality problems, including contamination with…

  10. Influence of redox condition in iron, silicon and hydrogen contents of leached glass surface

    International Nuclear Information System (INIS)

    Manara, A.; Lanza, F.; Della Mea, G.; Rossi, C.; Salvagno, G.

    1984-01-01

    Surface analysis has been conducted on samples leached in a Sochlet apparatus at 100 0 C in the presence and in the absence of air. The XPS technique was applied to analyze the content of iron and silicon while the nuclear reaction method was utilized to analyze the content of hydrogen. Samples leached in argon atmosphere have shown a smaller content of iron and silicon with respect to the samples leached in air atmosphere. The H concentration has shown the same behavior. The results are discussed in terms of possible formation of iron compounds in the different redox condition and of their different stabilities and in terms of their efficiency in reducing exchange between Na + and H + ions. 11 references, 3 figures, 1 table

  11. Identifying Typical Movements Among Indoor Objects

    DEFF Research Database (Denmark)

    Radaelli, Laura; Sabonis, Dovydas; Lu, Hua

    2013-01-01

    With the proliferation of mobile computing, positioning systems are becoming available that enable indoor location-based services. As a result, indoor tracking data is also becoming available. This paper puts focus on one use of such data, namely the identification of typical movement patterns...

  12. Vitality of plants to live in the indoor environment

    Science.gov (United States)

    Shamsuri, Mohd Mahathir Suhaimi; Leman, A. M.; Hariri, Azian; Idris, Ahmad Fu'ad; Afandi, Azizi

    2017-09-01

    Indoor air quality (IAQ) is generally a public concern because 90% of people spend their time indoor. IAQ must be preserved wisely to guarantee the health of the building occupants. One of the ways to maintain the quality of air is by placing plants in the building. However, all plants come from the outdoor, and the environment is different compared to indoor. Environmental factors such as temperature and light will absolutely affect the growth of the plant. Light and temperature that are too bright or too deem can wither the plants. Nevertheless, certain plant is capable of adapting with different situation after assimilation process has been conducted. This study intends to analyze the capacity of seven selected plants (Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, Spider Plant, and Syngonium) to live in an indoor environment. The vitality of plants is based on photosynthetic level that is measured using leaf - chamber (LI-COR 6400). Two groups of plants were located in indoor and outdoor (indigenous location) setting, and were allowed to assimilate for two months before measurement were carried out. The results for the plant located indoor shows that only Spider Plant cannot perform photosynthesis under 300 lux, where the photosynthetic value remains negative. Meanwhile, other plants such as Anthurium, Dumb Cane, Golden Pothos, Kadaka Fern, Prayer Plant, and Syngonium that were left indoor showed similar 300 lux in which conform the ability of the plants to perform photosynthesis with the value of 0.3, 0.15, 0.35, 0.1, 0.15, and 0.1. In comparison, all of the plants that were stationed indoor and outdoor (except Spider Plant), the light compensation point (LCP) for indoor shows smaller value than the outdoor. This is because all the indoor plants had down - regulated their photosynthesis process by becoming more sensitive to light after their assimilation. From this study, it can be concluded that all plants except Spider Plant is able to live

  13. Assessment of indoor environment of buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Y.; Kovanen, K. [VTT Building Technology, Espoo (Finland). Indoor Environment and Systems

    1995-12-31

    The synthetical assessment of indoor environment has become world-wide topic in recent years. Many research evidences have shown that the quality of indoor air is a multi-factor influenced issue. Building Research Establishment (BRE) in United Kingdom has worked out a series of assessing methods for different kinds of buildings. Whereas, in Finland, National Building Code of Finland has been used for many years. The comparison between the two approaches in assessing indoor air quality will be addressed in this presentation. Each issue considered in the above two approaches is discussed by referring the recent research highlights. (author)

  14. Assessment of indoor environment of buildings

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Y; Kovanen, K [VTT Building Technology, Espoo (Finland). Indoor Environment and Systems

    1996-12-31

    The synthetical assessment of indoor environment has become world-wide topic in recent years. Many research evidences have shown that the quality of indoor air is a multi-factor influenced issue. Building Research Establishment (BRE) in United Kingdom has worked out a series of assessing methods for different kinds of buildings. Whereas, in Finland, National Building Code of Finland has been used for many years. The comparison between the two approaches in assessing indoor air quality will be addressed in this presentation. Each issue considered in the above two approaches is discussed by referring the recent research highlights. (author)

  15. Sampling strategies for indoor radon investigations

    International Nuclear Information System (INIS)

    Prichard, H.M.

    1983-01-01

    Recent investigations prompted by concern about the environmental effects of residential energy conservation have produced many accounts of indoor radon concentrations far above background levels. In many instances time-normalized annual exposures exceeded the 4 WLM per year standard currently used for uranium mining. Further investigations of indoor radon exposures are necessary to judge the extent of the problem and to estimate the practicality of health effects studies. A number of trends can be discerned as more indoor surveys are reported. It is becoming increasingly clear that local geological factors play a major, if not dominant role in determining the distribution of indoor radon concentrations in a given area. Within a giving locale, indoor radon concentrations tend to be log-normally distributed, and sample means differ markedly from one region to another. The appreciation of geological factors and the general log-normality of radon distributions will improve the accuracy of population dose estimates and facilitate the design of preliminary health effects studies. The relative merits of grab samples, short and long term integrated samples, and more complicated dose assessment strategies are discussed in the context of several types of epidemiological investigations. A new passive radon sampler with a 24 hour integration time is described and evaluated as a tool for pilot investigations

  16. Indoor wayfinding and navigation

    CERN Document Server

    2015-01-01

    Due to the widespread use of navigation systems for wayfinding and navigation in the outdoors, researchers have devoted their efforts in recent years to designing navigation systems that can be used indoors. This book is a comprehensive guide to designing and building indoor wayfinding and navigation systems. It covers all types of feasible sensors (for example, Wi-Fi, A-GPS), discussing the level of accuracy, the types of map data needed, the data sources, and the techniques for providing routes and directions within structures.

  17. Indoor aerosols

    DEFF Research Database (Denmark)

    Morawska, L.; Afshari, Alireza; N. Bae, G.

    2013-01-01

    Motivated by growing considerations of the scale, severity, and risks associated with human exposure to indoor particulate matter, this work reviewed existing literature to: (i) identify state-of-the-art experimental techniques used for personal exposure assessment; (ii) compare exposure levels...

  18. Fatigability in basic indoor mobility in nonagenarians

    DEFF Research Database (Denmark)

    Mänty, Minna Regina; Ekmann, Anette; Thinggaard, Mikael

    2012-01-01

    To evaluate the prevalence and associated health factors of indoor mobility-related fatigability in nonagenarians.......To evaluate the prevalence and associated health factors of indoor mobility-related fatigability in nonagenarians....

  19. Indoor Air Quality Science and Technology

    Science.gov (United States)

    Understand indoor air in homes, schools, and offices. Most of us spend much of our time indoors. The air that we breathe in our homes, in schools, and in offices can put us at risk for health problems. Some pollutants can be chemicals, gases, and living or

  20. [Indoor volatile organic compounds: concentrations, sources, variation factors].

    Science.gov (United States)

    Palot, A; Charpin-Kadouch, C; Ercoli, J; Charpin, D

    2008-06-01

    Volatile organic compounds (V.O.C.) are part of urban air pollution and are also generated indoors from cleaning and maintenance products. VOC measurements are, on average, 10 times higher within homes than outside. Results of the national survey led by the Observatoire National de la Qualité de l'Air Intérieur demonstrated that up to 25% of French homes have very high or high concentrations of VOC. Indoor levels depend mainly on indoor sources. Aldehydes are included in many everyday life products. VOC originate from various household decorating and cleaning products. Some products are less detrimental to the environment and health and have special labelling. Indoor VOC levels also depend on the rate of air exchange and on household characteristics such as indoor temperature and humidity, age of the building, presence of smokers, and communication with a garage. The public may participate in maintaining good indoor air quality and the authorities should also improve regulations. VOC are part of everyday air pollution. Their sources and concentrations should be better monitored.

  1. Enhancing indoor air quality -The air filter advantage.

    Science.gov (United States)

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality.

  2. Indoor radon measurements in Mexico City

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, G. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Apartado Postal 20364, 01000 Mexico, D.F. (Mexico)], E-mail: espinosa@fisica.unam.mx; Golzarri, J.I. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Apartado Postal 20364, 01000 Mexico, D.F. (Mexico); Bogard, J. [Oak Ridge National Laboratory, PO Box 2008, Oak Ridge, TN 37831-6480 (United States); Gaso, I. [Instituto Nacional de Investigaciones Nucleares, Apartado Postal 18-1027, 11801 Mexico, D.F. (Mexico); Ponciano, G. [Facultad de Medicina, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, 04510 Mexico, D.F. (Mexico); Mena, M.; Segovia, N. [Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, 04510 Mexico, D.F. (Mexico)

    2008-08-15

    Mexico City is one of the most populated cities in the world with almost 22 million inhabitants, located at an altitude of 2200 m. The old city was founded on an ancient lake and the zone is known by its high seismicity; indoor radon determination is an important public health issue. In this paper the data of indoor radon levels in Mexico City, measured independently by two research groups, both using Nuclear Track Detector systems but different methodologies, are correlated. The measurements were done during similar exposure periods of time, at family houses from the political administrative regions of the city. The results indicate a correlation coefficient between the two sets of data of R=0.886. Most of the differences between the two sets of data are inherent to houses having extreme (very high or very low indoor radon) included in the statistics of each group. The total average indoor radon found in Mexico City considering the two methods was 87Bqm{sup -3}.

  3. Winter-to-winter variations in indoor radon

    International Nuclear Information System (INIS)

    Mose, D.G.; Mushrush, G.W.; Kline, S.W.

    1989-01-01

    Indoor radon concentrations in northern Virginia and central Maryland show a strong dependence on weather. Winter tends to be associated with higher than average indoor radon, and summer with lower than average. However, compared to the winter of 1986-1987, the winter of 1987-1988 was warmer and drier. Consequently, winter-to-winter indoor radon decreased by about 25%. This winter-to-winter decrease is unexpectedly large, and simulates winter-to-summer variations that have been reported

  4. Cooperative Agreement Funding for Indoor Air Quality

    Science.gov (United States)

    The Indoor Environments Division has created partnership with public and private sector entities to help encourage the public to take action to minimize their risk and mitigate indoor air quality problems.

  5. Oceanic and coastal dissolved iron observations from 1978-01-01 to 2004-12-31 (NCEI Accession 0067344)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Keith Moore observational dissolved Iron database. Moore expanded the original iron database complied by Parekh et al. (2005. The complete dataset with references to...

  6. Indoor radon II

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Because of the growing interest in and public concern about indoor radon, APCA, in April 1987, sponsored the Second International Specialty Conference on Indoor Radon. This book is the proceedings of this conference and includes discussions on: A current assessment of the nature of the problem; Issues related to health effects and risk assessment; The development of public and private sector initiatives; Research into methods of control and prevention; International perspectives; and Measurement methods and programs. The material is intended for the technically oriented and for those responsible for developing programs and initiatives to address this important public health issue. Contributors include federal, state, and provincial program officials and members of the academic and private sectors

  7. Adsorption studies of water on copper, nickel, and iron: assessment of the polarization model

    International Nuclear Information System (INIS)

    Lee, S.; Staehle, R.W.

    1997-01-01

    In the atmospheric corrosion of copper, nickel, and iron, the adsorption of water affects the corrosion rates. Knowledge of water adsorption and metal oxyhydroxide formation is important in understanding the atmospheric corrosion process. The purposes of the present research were (i) to measure the adsorption of water on metal surfaces as a function of temperature and relative humidity (RH) and (ii) to assess Bradley's polarization model of adsorption. In the present research, the quartz-crystal microbalance (QCM) technique was used to measure the mass changes of copper, nickel, and iron at 0 to 100% relative humidity and 7 to 90 C under nitrogen and air environments. Less water was adsorbed on copper, nickel, and iron which form oxides than on gold. The amount of water adsorption was similar on copper, nickel, and iron under N 2 and air carrier gases. Functional relationship was first proposed as a way to include dipole/induced dipole interactions between the adsorbents and water layers. (orig.)

  8. Photocatalytic surface reactions on indoor wall paint.

    Science.gov (United States)

    Salthammer, T; Fuhrmann, F

    2007-09-15

    The reduction of indoor air pollutants by air cleaning systems has received considerable interest, and a number of techniques are now available. So far, the method of photocatalysis was mainly applied by use of titanium dioxide (TiO2) in flow reactors under UV light of high intensity. Nowadays, indoor wall paints are equipped with modified TiO2 to work as a catalyst under indoor daylight or artificial light. In chamber experiments carried out under indoor related conditions itwas shown thatthe method works for nitrogen dioxide with air exchange and for formaldehyde without air exchange at high concentrations. In further experiments with volatile organic compounds (VOCs), a small effect was found for terpenoids with high kOH rate constants. For other VOCs and carbon monoxide there was no degradation at all or the surface acted as a reversible sink. Secondary emissions from the reaction of paint constituents were observed on exposure to light. From the results it is concluded that recipes of photocatalytic wall paints need to be optimized for better efficiency under indoor conditions.

  9. Reevaluation of time spent indoors used for exposure dose assessment

    International Nuclear Information System (INIS)

    Hirose, Katsumi; Fujimoto, Kenzo

    2016-01-01

    A time spent indoors of sixteen hours per day (indoor occupancy factor: 0.67) has been used to assess the radiation dose of residents who spend daily life in the area contaminated due to the nuclear accident in Japan. However, much longer time is considered to be spent indoors for recent modern life. United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) has been used an indoor occupancy factor of 0.8 since 1977 and a few reports suggested much higher indoor occupancy factors. Therefore it is important to reevaluate the indoor occupancy factor using current available survey data in Japan, such as 'NHK 2010 National Time Use Survey' and 'Survey on Time Use and Leisure Activities' of Statistics Bureau with certain assumption of time spent indoors in each daily activity. The total time spent indoors in a day is calculated to be 20.2 hours and its indoor occupancy factor is 0.84. Much lower indoor occupancy factors were derived from the survey data by Statistics Bureau for 10 to 14 and 15 to 19 years old groups and farmers who spend most of their time outdoors although present estimated indoor occupancy factor of 0.84 is still lower than those found in some of the relevant reports. A rounded indoor occupancy factor of 0.80 might be the appropriate conservative reference value to be used for the dose estimation of people who live in radioactively contaminated areas and for other relevant purposes of exposure assessment, taken into consideration the present results and values reported in United States Environmental Protection Agency (US EPA) and UNSCEAR. (author)

  10. Indoor particle dynamics in a school office: determination of particle concentrations, deposition rates and penetration factors under naturally ventilated conditions.

    Science.gov (United States)

    Cong, X C; Zhao, J J; Jing, Z; Wang, Q G; Ni, P F

    2018-05-09

    Recently, the problem of indoor particulate matter pollution has received much attention. An increasing number of epidemiological studies show that the concentration of atmospheric particulate matter has a significant effect on human health, even at very low concentrations. Most of these investigations have relied upon outdoor particle concentrations as surrogates of human exposures. However, considering that the concentration distribution of the indoor particulate matter is largely dependent on the extent to which these particles penetrate the building and on the degree of suspension in the indoor air, human exposures to particles of outdoor origin may not be equal to outdoor particle concentration levels. Therefore, it is critical to understand the relationship between the particle concentrations found outdoors and those found in indoor micro-environments. In this study, experiments were conducted using a naturally ventilated office located in Qingdao, China. The indoor and outdoor particle concentrations were measured at the same time using an optical counter with four size ranges. The particle size distribution ranged from 0.3 to 2.5 μm, and the experimental period was from April to September, 2016. Based on the experimental data, the dynamic and mass balance model based on time was used to estimate the penetration rate and deposition rate at air exchange rates of 0.03-0.25 h -1 . The values of the penetration rate and deposition velocity of indoor particles were determined to range from 0.45 to 0.82 h -1 and 1.71 to 2.82 m/h, respectively. In addition, the particulate pollution exposure in the indoor environment was analyzed to estimate the exposure hazard from indoor particulate matter pollution, which is important for human exposure to particles and associated health effects. The conclusions from this study can serve to provide a better understanding the dynamics and behaviors of airborne particle entering into buildings. And they will also highlight

  11. Contrasts in spatial and temporal variability of oxidative capacity and elemental composition in moxibustion, indoor and outdoor environments in Beijing

    International Nuclear Information System (INIS)

    Huang, Jian; Lim, Min Yee; Hwang, Chaxi; Zhao, Baixiao; Shao, Longyi

    2015-01-01

    Moxibustion is a traditional Chinese medicine therapy that burns moxa floss which produces a substantial amount of PM 10 into the environment, thus spawning safety concerns about health impacts of the smoke. We compared the oxidative capacity and elemental composition of moxibustion-derived and ambient PM 10 in summer and winter to provide a source-, spatial- and temporal-comparison of PM 10 biological responses. The PM 10 oxidative capacity was 2.04 and 1.45 fold lower, and dose-dependent slope gradient was 2.36 and 1.76 fold lower in moxibustion environment than indoor or outdoor. Oxidative damage was highly correlated with iron, cesium, aluminum and cobalt in indoor, but moxibustion environment displayed low associations. The total elemental concentration was also lower in moxibustion environment than indoor (2.28 fold) or outdoor (2.79 fold). The source-to-dose modeling and slope gradient analysis in this study can be used as a model for future source-, spatial- and temporal-related moxibustion safety evaluation studies. - Highlights: • Source-, spatial- and temporal-comparisons of PM 10 of moxa smoke and ambient air. • Moxibustion environment had the lowest oxidative capacity temporally and spatially. • Total elemental concentration was also lowest in moxibustion environment. • Low correlations between metals and oxidative damage in moxibustion environment. • Moxibustion-derived PM 10 may not be as injurious to human health as thought. - Moxibustion-derived PM 10 had the lowest oxidative capacity and total elemental concentration when compared with indoor and outdoor environments

  12. Light-induced heterogeneous reactions of NO2 on indoor surfaces: How they affect the balance of nitrous acid

    Science.gov (United States)

    Gomez Alvarez, E.; Soergel, M.; Bassil, S.; Zetzsch, C.; Gligorovski, S.; Wortham, H.

    2011-12-01

    Nitrous acid (HONO) is an important indoor pollutant. The adverse health effects due to the formation of nitrosamines are well known. HONO acts as a nitrosating agent after wall reactions of HONO with nicotine [Sleiman et al., 2010]. Indoor air can be surprisingly rich in HONO (homes with fireplaces, stoves, gas heating and cooking) and also surfaces are abundant. High HONO concentrations have been measured in indoor environments, from the direct emissions and heterogeneous reactions of NO2 in darkness. However, the measured HONO concentrations do not correspond to the HONO levels determined by the models [Carslaw, 2007]. We have tested in a flow tube reactor on-line coupled to a NOx analyzer and a sensitive Long Path Absorption Photometry instrument, the behaviour of various indoor surfaces towards NO2 under simulated solar light irradiation (λ= 300-700 nm). Our study has allowed us to obtain a deeper knowledge on the mechanisms of heterogeneous formation of HONO, quantifying the dependence of HONO formation on behalf of NO2 concentration and relative humidity and the enhancement of HONO formation in the presence of light. Pyrex, acidic detergent, alkaline detergent, paint and lacquer were tested on behalf of their heterogeneous reactivity towards NO2 in the absence and in presence of light. The results obtained demonstrated that indoor surfaces are photo-chemically active under atmospherically relevant conditions. The strongly alkaline surfaces (such as certain types of detergent) show a strong long-term uptake capacity. However, other surfaces such as detergents with a more acidic character released HONO. In some cases such as paint and varnish, a strong HONO release with light was detected, which was significantly higher than that obtained over clean glass surfaces. Certain organics present on their composition could exert a photo-sensitizing effect that may explain their increased reactivity. Unfortunately, the final balance points towards an important net

  13. Design Criteria for Achieving Acceptable Indoor Radon Concentration

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2016-01-01

    Design criteria for achieving an acceptable indoor radon concentration are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization...... in most countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. The first two criteria can prevent radon from infiltrating...... from the ground, and the third criteria can dilute the indoor air. By combining these three criteria, the indoor radon concentration can be lowered achieving an acceptable level. In addition, a cheap and reliable method for measuring the radon concentration in the indoor air is described. The provision...

  14. Native iron

    DEFF Research Database (Denmark)

    Brooks, Charles Kent

    2015-01-01

    System, was reduced. The oxidized outer layers of the Earth have formed by two processes. Firstly, water is decomposed to oxygen and hydrogen by solar radiation in the upper parts of the atmosphere, the light hydrogen diffusing to space, leaving oxygen behind. Secondly, plants, over the course......, hematite, or FeO.Fe2O3, magnetite), with carbon in the form of coke. This is carried out in a blast furnace. Although the Earth's core consists of metallic iron, which may also be present in parts of the mantle, this is inaccessible to us, so we must make our own. In West Greenland, however, some almost......We live in an oxidized world: oxygen makes up 22 percent of the atmosphere and by reacting with organic matter produces most of our energy, including the energy our bodies use to function: breathe, think, move, etc. It has not always been thus. Originally the Earth, in common with most of the Solar...

  15. Size-resolved mass concentrations of iron oxide aerosols and size-resolved number concentrations of iron oxide aerosols collected from King Air aircraft in Yellow Sea and East China Sea from 2013-02-14 to 2013-03-10 (NCEI Accession 0162201)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains size-resolved mass concentrations of iron oxide aerosols and size-resolved number concentrations of iron oxide aerosols, measured using the...

  16. The effects of metamorphism on iron mineralogy and the iron speciation redox proxy

    Science.gov (United States)

    Slotznick, Sarah P.; Eiler, John M.; Fischer, Woodward W.

    2018-03-01

    As the most abundant transition metal in the Earth's crust, iron is a key player in the planetary redox budget. Observations of iron minerals in the sedimentary record have been used to describe atmospheric and aqueous redox environments over the evolution of our planet; the most common method applied is iron speciation, a geochemical sequential extraction method in which proportions of different iron minerals are compared to calibrations from modern sediments to determine water-column redox state. Less is known about how this proxy records information through post-depositional processes, including diagenesis and metamorphism. To get insight into this, we examined how the iron mineral groups/pools (silicates, oxides, sulfides, etc.) and paleoredox proxy interpretations can be affected by known metamorphic processes. Well-known metamorphic reactions occurring in sub-chlorite to kyanite rocks are able to move iron between different iron pools along a range of proxy vectors, potentially affecting paleoredox results. To quantify the effect strength of these reactions, we examined mineralogical and geochemical data from two classic localities where Silurian-Devonian shales, sandstones, and carbonates deposited in a marine sedimentary basin with oxygenated seawater (based on global and local biological constraints) have been regionally metamorphosed from lower-greenschist facies to granulite facies: Waits River and Gile Mountain Formations, Vermont, USA and the Waterville and Sangerville-Vassalboro Formations, Maine, USA. Plotting iron speciation ratios determined for samples from these localities revealed apparent paleoredox conditions of the depositional water column spanning the entire range from oxic to ferruginous (anoxic) to euxinic (anoxic and sulfidic). Pyrrhotite formation in samples highlighted problems within the proxy as iron pool assignment required assumptions about metamorphic reactions and pyrrhotite's identification depended on the extraction techniques

  17. Publications and Resources About Indoor airPLUS

    Science.gov (United States)

    Presented are useful materials to help you build homes that meet Indoor airPLUS specifications and to promote Indoor airPLUS qualified homes. These materials are FREE of charge and are available in PDF.

  18. Federal Interagency Committee on Indoor Air Quality

    Science.gov (United States)

    The Federal Interagency Committee on Indoor Air Quality (CIAQ), which meets three times a year, was established by Congress to coordinate the activities of the Federal Government on issues relating to Indoor Air Quality.

  19. Finding dense locations in indoor tracking data

    DEFF Research Database (Denmark)

    Ahmed, Tanvir; Pedersen, Torben Bach; Lu, Hua

    2014-01-01

    for semi-constrained indoor movement, and then uses this to map raw tracking records into mapping records representing object entry and exit times in particular locations. Then, an efficient indexing structure, the Dense Location Time Index (DLT-Index) is proposed for indexing the time intervals...... of the mapping table, along with associated construction, query processing, and pruning techniques. The DLT-Index supports very efficient aggregate point queries, interval queries, and dense location queries. A comprehensive experimental study with real data shows that the proposed techniques can efficiently......Finding the dense locations in large indoor spaces is very useful for getting overloaded locations, security, crowd management, indoor navigation, and guidance. Indoor tracking data can be very large and are not readily available for finding dense locations. This paper presents a graph-based model...

  20. The distribution of indoor radon in Transylvania (Romania) - influence of the natural and anthropogenic factors

    Science.gov (United States)

    Cucos Dinu, Alexandra; Baciu, Calin; Dicu, Tiberius; Papp, Botond; Moldovan, Mircea; Bety Burghele, Denissa; Tenter, Ancuta; Szacsvai, Kinga

    2017-04-01

    Exposure to radon in homes and workplaces is now recognized as the most important natural factor in causing lung cancer. Radon activity is usually higher in buildings than in the outside atmosphere, as it may be released from building materials and soil beneath the constructions, and the concentration builds-up indoor, due to the low air renewal rates. Indoor radon levels can vary from one to multiple orders of magnitude over time and space, as it depends on several natural and anthropogenic factors, such us the radon concentration in soil under the construction, the weather conditions, the degree of containment in the areas where individuals are exposed, building materials, outside air, tap water and even city gas, the architecture, equipment (chimney, mechanical ventilation systems, etc.), the environmental parameters of the building (temperature, pressure, etc.), and on the occupants' lifestyle. The study presents the distribution of indoor radon in Transylvania, Romania, together with the measurements of radon in soil and soil water. Indoor radon measurements were performed by using CR-39 track detectors exposed for 3 months on ground-floor level of dwellings, according to the NRPB Measurement Protocol. Radon concentrations in soil and water were measured using the LUK3C device. A complete map was plotted at the date, based on 3300 indoor radon measurements, covering an area of about 42% of the Romanian territory. The indoor radon concentrations ranged from 5 to 3287 Bq m-3, with an updated preliminary arithmetic mean of 179 Bq m-3, and a geometric mean of 122 Bq m-3. In about 11% of the investigated grid cells the indoor radon concentrations exceed the threshold of 300 Bq m-3. The soil gas radon concentration varies from 0.8 to 169 kBq m-3, with a geometric mean of 26 kBq m-3. For water samples, the results show radon concentrations within the range of 0.3 - 352.2 kBq m-3, with a geometric mean of 7.7 Bq L-1. A weak correlation between the three sets of values

  1. Indoor randon concentration. Temperature and wind effects; Concentrazione di radon indoor. Effetto del vento e della temperatura

    Energy Technology Data Exchange (ETDEWEB)

    Sesana, L.; Benigni, S. [Milan Univ., Milan (Italy). Ist. di Fisica Generale Applicata

    2000-12-01

    The present study analyses and discusses the behaviour of the indoor radon concentration in a research house. Hourly measurements were carried out in the basement of the house from November 1998 up to June 1999. In many sequences of days radon concentration in the room under analysis shows strong variation all day long with accumulation in the evening and overnight and decrease in the morning and in the afternoon. Measurements of wind velocity, indoor and outdoor temperatures and outdoor-indoor pressure difference were performed and their trend is compared with the observed radon concentration. The exhalation of radon from walls, floor and ceiling and the pressure difference driven exhalation from the soil are discussed, particularly the relation with the temperature differences. The air exchange rates between the house and the outdoor air are studied. [Italian] Si analizza e si discute il comportamento della concentrazione di radon indoor nel seminterrato di una casa di ricerca. Misure orarie sono state effettuate da novembre 1998 a giugno 1999. In molte sequenze di giorni la concentrazione del radon nel locale in analisi presenta forti variazioni nel corso della giornata con un accumulo notturno e decrescita nelle ore diurne. Sono state eseguite misure della velocita' del vento, delle temperature outdoor e indoor e della differenza di pressione outdoor-indoor e il loro andamento e' stato confrontato con quello della concentrazione del radon. Vengono discusse l'esalazione del radon dalle pareti, dal pavimento e dal soffitto e l'esalazione pressure difference driven dal suolo. Il rateo dei ricambi d'aria tra il locale e l'aria outdoor e' studiato.

  2. Next Generation Metallic Iron Nodule Technology in Electric Arc Steelmaking - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Donald R. Fosnacht; Iwao Iwasaki; Richard F. Kiesel; David J. Englund; David W. Hendrickson; Rodney L. Bleifuss

    2010-12-22

    The current trend in the steel industry is a gradual decline in conventional steelmaking from taconite pellets in blast furnaces, and an increasing number of alternative processes using metallic scrap iron, pig iron and metallized iron ore products. Currently, iron ores from Minnesota and Michigan are pelletized and shipped to the lower Great Lakes ports as blast furnace feed. The existing transportation system and infrastructure is geared to handling these bulk materials. In order to expand the opportunities for the existing iron ore mines beyond their blast furnace customer base, a new material is needed to satisfy the needs of the emerging steel industry while utilizing the existing infrastructure and materials handling. A recent commercial installation employing Kobe Steel’s ITmk3 process, was installed in Northeastern Minnesota. The basic process uses a moving hearth furnace to directly reduce iron oxides to metallic iron from a mixture of iron ore, coals and additives. The resulting products can be shipped using the existing infrastructure for use in various steelmaking processes. The technology reportedly saves energy by 30% over the current integrated steelmaking process and reduces emissions by more than 40%. A similar large-scale pilot plant campaign is also currently in progress using JFE Steel’s Hi-QIP process in Japan. The objective of this proposal is to build upon and improve the technology demonstrated by Kobe Steel and JFE, by further reducing cost, improving quality and creating added incentive for commercial development. This project expands previous research conducted at the University of Minnesota Duluth’s Natural Resources Research Institute and that reported by Kobe and JFE Steel. Three major issues have been identified and are addressed in this project for producing high-quality nodular reduced iron (NRI) at low cost: (1) reduce the processing temperature, (2) control the furnace gas atmosphere over the NRI, and (3) effectively use sub

  3. Health effects of indoor odorants.

    Science.gov (United States)

    Cone, J E; Shusterman, D

    1991-11-01

    People assess the quality of the air indoors primarily on the basis of its odors and on their perception of associated health risk. The major current contributors to indoor odorants are human occupant odors (body odor), environmental tobacco smoke, volatile building materials, bio-odorants (particularly mold and animal-derived materials), air fresheners, deodorants, and perfumes. These are most often present as complex mixtures, making measurement of the total odorant problem difficult. There is no current method of measuring human body odor, other than by human panel studies of expert judges of air quality. Human body odors have been quantitated in terms of the "olf" which is the amount of air pollution produced by the average person. Another quantitative unit of odorants is the "decipol," which is the perceived level of pollution produced by the average human ventilated by 10 L/sec of unpolluted air or its equivalent level of dissatisfaction from nonhuman air pollutants. The standard regulatory approach, focusing on individual constituents or chemicals, is not likely to be successful in adequately controlling odorants in indoor air. Besides the current approach of setting minimum ventilation standards to prevent health effects due to indoor air pollution, a standard based on the olf or decipol unit might be more efficacious as well as simpler to measure.

  4. Health and economic benefits of building ventilation interventions for reducing indoor PM2.5 exposure from both indoor and outdoor origins in urban Beijing, China.

    Science.gov (United States)

    Yuan, Ye; Luo, Zhiwen; Liu, Jing; Wang, Yaowu; Lin, Yaoyu

    2018-06-01

    China is confronted with serious PM 2.5 pollution, especially in the capital city of Beijing. Exposure to PM 2.5 could lead to various negative health impacts including premature mortality. As people spend most of their time indoors, the indoor exposure to PM 2.5 from both indoor and outdoor origins constitutes the majority of personal exposure to PM 2.5 pollution. Different building interventions have been introduced to mitigate indoor PM 2.5 exposure, but always at the cost of energy expenditure. In this study, the health and economic benefits of different ventilation intervention strategies for reducing indoor PM 2.5 exposure are modeled using a representative urban residence in Beijing, with consideration of different indoor PM 2.5 emission strengths and outdoor pollution. Our modeling results show that the increase of envelope air-tightness can achieve significant economic benefits when indoor PM 2.5 emissions are absent; however, if an indoor PM 2.5 source is present, the benefits only increase slightly in mechanically ventilated buildings, but may show negative benefit without mechanical ventilation. Installing mechanical ventilation in Beijing can achieve annual economic benefits ranging from 200yuan/capita to 800yuan/capita if indoor PM 2.5 sources exist. If there is no indoor emission, the annual benefits above 200yuan/capita can be achieved only when the PM 2.5 filtration efficiency is no urban Beijing will increase the indoor PM 2.5 exposure and result in excess costs to the residents. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Indoor Air Quality: Maryland Public Schools.

    Science.gov (United States)

    Maryland State Dept. of Education, College Park. Office of Administration and Finance.

    Less than adequate indoor air quality in schools can lead to a higher risk of health problems, an increase in student and teacher absenteeism, diminished learning, and even hazardous conditions. An indoor air quality program that addresses the planning, design, maintenance, and operation of public school buildings should be implemented at the…

  6. Exposure to indoor air pollution in a reconstructed house from the Danish Iron Age

    Science.gov (United States)

    Skov, Henrik; Stenholt Christensen, Carsten; Fenger, Jes; Essenbæk, Merete; Larsen, Dyveke; Sørensen, Lasse

    The adverse effects of air pollution on health have been recognised for millennia, but only in recent centuries they have been directly documented. In this paper evidence of the levels of exposure in the Danish Iron Age has been obtained from real measurements. The personal exposure to NO 2 was measured over one week from 6 to 13 February 1999 for a person living in a reconstructed house from the Danish Iron Age (500 BC-700 AD). At the same time NO 2 was measured close to the fireplace and next to the beds as well as outdoor at a distance of about 20 m from the house. Finally, 1 h average concentrations of benzene were measured for a 24 h period during the exposure measurement. A weekly average exposure of NO 2 was measured to be 61.6 μg N m -3. In the house as high as 110.8 μg N m -3 weekly average was measured for NO 2 and a 24 h average value of 45.8 μg m -3 was determined for benzene. The exposure is compared with the present levels.

  7. About the Subdivision of Indoor Spaces in Indoorgml

    Science.gov (United States)

    Diakité, A. A.; Zlatanova, S.; Li, K.-J.

    2017-10-01

    Boosted by the dynamic urbanization of cities, indoor environments are getting more and more complex in order to be able to host people properly. While most of our time is spent inside buildings, the need of GIS tools to assist our daily activities that can become tedious, such as indoor navigation or facility management, became more and more urgent. In that perspective, the IndoorGML standard is aiming to address the gaps left by other standards regarding the spatial modelling for indoor navigation. It includes several concepts such as the organization of the spaces into cells along with their network representation and the possibility to represent multiple connected layers. However, being at its first stage, several concepts of the standard could be improved. One of these is the cell subspacing that is not enough discussed in the current version of the standard. In this paper, we explore all the aspects involved in the subdivision process, from the identification of the navigable and non-navigable space cells to the generation of a navigation graph. We propose several criteria on which the indoor sub-spacing can rely to be automatically performed and and illustrate them on a 3D indoor model.

  8. Soil as a source of indoor 220Rn

    International Nuclear Information System (INIS)

    Li, Y.; Schery, S.D.; Turk, B.

    1992-01-01

    Two suggestions for sources of indoor 220Rn (thoron) have appeared in the literature: (1) building materials and outside air, and (2) soil beneath the house. Due to the difficulty of 220Rn measurement and limited data, both suggestions lack sufficient supporting evidence. We have investigated sources of indoor 220Rn in seven occupied houses in northern New Mexico, U.S. A two-filter system was used to measure indoor 220Rn levels continuously, and 220Rn progeny were measured with single filters and specialized alpha-track detectors. The amount of 220Rn entry from soil was curtailed by cutting off soil gas flow to the indoor air with subfloor depressurization mitigation systems. Four of the houses showed significant reductions in 220Rn with mitigation systems on. The average effect for these houses was to reduce indoor 220Rn levels by 70%. The other three houses had no clear reductions but in one of these houses, the mitigation system was not effective for stopping soil gas flow. Our results provide some of the most clear evidence to date supporting soil as an important source of indoor 220Rn

  9. Immediate impact of smoke-free laws on indoor air quality.

    Science.gov (United States)

    Lee, Kiyoung; Hahn, Ellen J; Riker, Carol; Head, Sara; Seithers, Peggy

    2007-09-01

    Smoke-free laws significantly impact indoor air quality. However, the temporal effects of these laws on indoor air pollution have not been determined. This paper assesses the temporal impact of one smoke-free law on indoor air quality. This quasi-experimental study compared the indoor air quality of nine hospitality venues and one bingo hall in Georgetown, Kentucky, before and after implementation of a 100% smoke-free workplace law. We made real-time measurements of particulate matter with 2.5 microm aerodynamic diameter or smaller (PM2.5). Among the nine Georgetown hospitality venues, the average indoor PM2.5 concentration was 84 microg/m3 before the law took effect. The average indoor PM2.5 concentrations in nine compliant venues significantly decreased to 18 microg/m3 one week after the law took effect. Three venues having 82 microg/m3 before the law had significantly lower levels from the first day the law was implemented, and the low level was maintained. Compliance with the law is critical to achieving clean indoor air. Indoor air pollution in the bingo hall was not reduced until the establishment decided to comply with the law. The smoke-free law showed immediate impact on indoor air quality.

  10. The use of pesticides in Belgian illicit indoor cannabis plantations.

    Science.gov (United States)

    Cuypers, Eva; Vanhove, Wouter; Gotink, Joachim; Bonneure, Arne; Van Damme, Patrick; Tytgat, Jan

    2017-08-01

    Cannabis (Cannabis spp.) use and cultivation continue to increase in many (European) countries. The illicit indoor cannabis plantations that supply Belgian and European cannabis markets create problems and concerns about health and safety of intervention staff, dismantling companies, the direct environment of cannabis plantations and, eventually, of cannabis users. Main risks may come from pesticide residues on plants, cultivation infrastructure and materials; left-over plant growth-promoting substances; mycotoxins from fungal pathogens on harvested plants; and/or high levels of cannabinoids in cannabis plant parts for consumption. In the present research, we report on pesticides found in illicit indoor cannabis plantations in Belgium. EN15662 QuEChERS extraction method and LC-MS/MS analysis were used to identify pesticides in indoor cannabis plantations and thus to evaluate the hazards associated with the use, cultivation and removal of cannabis plants in plantations as well as with dismantling activities in the cultivation rooms. We found pesticides in 64.3% of 72 cannabis plant samples and in 65.2% of 46 carbon filter cloth samples. Overall, 19 pesticides belonging to different chemical classes were identified. We found o-phenylphenol, bifenazate, cypermethrin, imidacloprid, propamocarb, propiconazole and tebuconazole, which is consistent with the commonly reported pesticides from literature. In only a few cases, pesticides found in bottles with a commercial label, were also identified in plant or stagnant water samples collected from the growth rooms where the bottles had been collected. We further revealed that, even though most pesticides have a low volatility, they could be detected from the carbon filters hanging at the ceiling of cultivation rooms. As a result, it is likely that pesticides also prevail in the plantation atmosphere during and after cultivation. The risk of inhaling the latter pesticides increases when plants sprayed with pesticides are

  11. Pelagic Iron Recycling in the Southern Ocean: Exploring the Contribution of Marine Animals

    Directory of Open Access Journals (Sweden)

    Lavenia Ratnarajah

    2018-03-01

    Full Text Available The availability of iron controls primary productivity in large areas of the Southern Ocean. Iron is largely supplied via atmospheric dust deposition, melting ice, the weathering of shelf sediments, upwelling, sediment resuspension, mixing (deep water, biogenic, and vertical mixing and hydrothermal vents with varying degrees of temporal and spatial importance. However, large areas of the Southern Ocean are remote from these sources, leading to regions of low primary productivity. Recent studies suggest that recycling of iron by animals in the surface layer could enhance primary productivity in the Southern Ocean. The aim of this review is to provide a quantitative and qualitative assessment of the current literature on pelagic iron recycling by marine animals in the Southern Ocean and highlight the next steps forward in quantifying the retention and recycling of iron by higher trophic levels in the Southern Ocean. Phytoplankton utilize the iron in seawater to meet their metabolic demand. Through grazing, pelagic herbivores transfer the iron in phytoplankton cells into their body tissues and organs. Herbivores can recycle iron through inefficient feeding behavior that release iron into the water before ingestion, and through the release of fecal pellets. The iron stored within herbivores is transferred to higher trophic levels when they are consumed. When predators consume iron beyond their metabolic demand it is either excreted or defecated. Waste products from pelagic vertebrates can thus contain high concentrations of iron which may be in a form that is available to phytoplankton. Bioavailability of fecal iron for phytoplankton growth is influenced by a combination of the size of the fecal particle, presence of organic ligands, the oxidation state of the iron, as well as biological (e.g., remineralization, coprochaly, coprorhexy, and coprophagy and physical (e.g., dissolution, fragmentation processes that lead to the degradation and release of

  12. Towards an integrative approach of improving indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Bluyssen, Philomena M. [TNO Built Environment and Geosciences, P.O. Box 49, 2600 AA Delft (Netherlands)

    2009-09-15

    There seems to be a discrepancy between current Indoor Air Quality standards and end-users wishes and demands. Indoor air quality can be approached from three points of view: the human, the indoor air of the space and the sources contributing to indoor air pollution. Standards currently in use mainly address the indoor air of the space. ''Other or additional'' recommendations and guidelines are required to improve indoor air quality. Even though we do not fully understand the mechanisms behind the physical, chemical, physiological and psychological processes, it is still possible to identify the different ways to be taken regulatory, politically-socially (awareness), technically (process and product) and scientifically. Besides the fact that there is an urgent need to involve medicine and neuro-psychology in research to investigate the mechanisms behind dose-response, health effects and interactions between and with the other factors and parameters of the indoor environment and the human body and mind, a holistic approach is required including the sources, the air and last but not least the human beings (occupants) themselves. This paper mainly focuses on the European situation. (author)

  13. Dynamic behavior of semivolatile organic compounds in indoor air

    Energy Technology Data Exchange (ETDEWEB)

    Loy, Michael David Van [Univ. of California, Berkeley, CA (United States)

    1998-12-09

    Exposures to a wide range of air pollutants are often dominated by those occurring in buildings because of three factors: 1) most people spend a large fraction of their time indoors, 2) many pollutants have strong indoor sources, and 3) the dilution volume in buildings is generally several orders of magnitude smaller than that of an urban airshed. Semivolatile organic compounds (SVOCS) are emitted by numerous indoor sources, including tobacco combustion, cooking, carpets, paints, resins, and glues, so indoor gasphase concentrations of these compounds are likely to be elevated relative to ambient levels. The rates of uptake and release of reversibly sorbing SVOCS by indoor materials directly affect both peak concentrations and persistence of the pollutants indoors after source elimination. Thus, accurate predictions of SVOC dynamics in indoor air require an understanding of contaminant sorption on surface materials such as carpet and wallboard. The dynamic behaviors of gas-phase nicotine and phenanthrene were investigated in a 20 ms stainless steel chamber containing carpet and painted wallboard. Each compound was studied independently, first in the empty chamber, then with each sorbent individually, and finally with both sorbents in the chamber.

  14. Improving Wi-Fi Based Indoor Positioning Using Bluetooth Add-Ons

    DEFF Research Database (Denmark)

    Baniukevic, Artur; Sabonis, Dovydas; Jensen, Christian S.

    2011-01-01

    enabling indoor LBSs. Existing indoor positioning services typically use a single technology such as Wi-Fi, RFID or Bluetooth. Wi-Fi based indoor positioning is relatively easy to deploy, but does often not offer good positioning accuracy. In contrast, the use of RFID or Bluetooth for positioning requires...... considerable investments in equipment in order to ensure good positioning accuracy. Motivated by these observations, we propose a hybrid approach to indoor positioning. In particular, we introduce Bluetooth hotspots into an indoor space with an existing Wi-Fi infrastructure such that better positioning...

  15. Exposure to unusually high indoor radon levels

    International Nuclear Information System (INIS)

    Rasheed, F.N.

    1993-01-01

    Unusually high indoor radon concentrations were reported in a small village in western Tyrol, Austria. The authors have measured the seasonal course of indoor radon concentrations in 390 houses of this village. 71% of houses in winter and 33% in summer, showed radon values on the ground floor above the Austrian action level of 400 Bq/cm 3 . This proportion results in an unusually high indoor radon exposure of the population. The radon source was an 8,700-year-old rock slide of granite gneiss, the largest of the alpine crystalline rocks. It has a strong emanating power because its rocks are heavily fractured and show a slightly increased uranium content. Previous reports show increased lung cancer mortality, myeloid leukemia, kidney cancer, melanoma, and prostate cancer resulting from indoor radon exposure. However, many studies fail to provide accurate information on indoor radon concentrations, classifying them merely as low, intermediate, and high, or they record only minor increases in indoor radon concentrations. Mortality data for 1970-91 were used to calculate age and sex standardized mortality rates (SMR) for 51 sites of carcinoma. The total population of Tyrol were controls. A significantly higher risk was recorded for lung cancer. The high SMR for lung cancer in female subjects is especially striking. Because the numbers were low for the other cancer sites, these were combined in one group to calculate the SMR. No significant increase in SMR was found for this group

  16. DISC ATMOSPHERES AND WINDS IN X-RAY BINARIES

    Directory of Open Access Journals (Sweden)

    Maria Díaz Trigo

    2013-12-01

    Full Text Available We review the current status of studies of disc atmospheres and winds in low mass X-ray binaries. We discuss the possible wind launching mechanisms and compare the predictions of the models with the existent observations. We conclude that a combination of thermal and radiative pressure (the latter being relevant at high luminosities can explain the current observations of atmospheres and winds in both neutron star and black hole binaries. Moreover, these winds and atmospheres could contribute significantly to the broad iron emission line observed in these systems.

  17. An Innovative Gateway for Indoor Positioning

    Directory of Open Access Journals (Sweden)

    Marias Giannis F

    2006-01-01

    Full Text Available Enabling the pervasive paradigm requires the incorporation of location information. Retrieving location data has been a field of ongoing research for both the outdoor and indoor wireless systems. The results in the cellular scenario are already mature and location architectures have been standardized. Recent research is ongoing for indoor-positioning mechanisms, resulting in implementations that vary. A platform that enables the deployment of location-based services in heterogeneous indoor and WLAN-based communication systems will address difficulties in cooperating with different positioning systems. For that purpose, we have designed a novel entity, called Gateway WLAN Location Center (GWLC, which hides the heterogeneous functions of the indoor positioning architectures, incorporating a unified framework for retrieving location data of users and objects. The GWLC platform has been designed to meet objectives such as modularity, scalability, as well as portability, and to facilitate open interfaces. In this contribution, we elaborate on the design principles and the functionality of GWLC. We also provide performance results, obtained through real experiments.

  18. Indoor air quality in low-energy houses in the Netherlands: Does mechanical ventilation provide a healthy indoor environment?

    NARCIS (Netherlands)

    Balvers, J.R.; Boxem, G.; Wit, de M.H.; Strøm-Tejsen, P; Olesen, B.W.; Wargocki, P; Zukowska, D; Toftum, J

    2008-01-01

    Increasing environmental awareness has led to new, energy-efficient building standards such as the German Passivhaus-standard. This study was designed to investigate the indoor air quality (IAQ) of four different Dutch low-energy houses built according to this standard. Air flow, indoor air

  19. Monitoring Indoor Air Quality for Enhanced Occupational Health.

    Science.gov (United States)

    Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque

    2017-02-01

    Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".

  20. Monocular Vision SLAM for Indoor Aerial Vehicles

    Directory of Open Access Journals (Sweden)

    Koray Çelik

    2013-01-01

    Full Text Available This paper presents a novel indoor navigation and ranging strategy via monocular camera. By exploiting the architectural orthogonality of the indoor environments, we introduce a new method to estimate range and vehicle states from a monocular camera for vision-based SLAM. The navigation strategy assumes an indoor or indoor-like manmade environment whose layout is previously unknown, GPS-denied, representable via energy based feature points, and straight architectural lines. We experimentally validate the proposed algorithms on a fully self-contained microaerial vehicle (MAV with sophisticated on-board image processing and SLAM capabilities. Building and enabling such a small aerial vehicle to fly in tight corridors is a significant technological challenge, especially in the absence of GPS signals and with limited sensing options. Experimental results show that the system is only limited by the capabilities of the camera and environmental entropy.

  1. Normal and seasonally amplified indoor radon levels

    International Nuclear Information System (INIS)

    Gammage, R.B.; Dudney, C.S.; Wilson, D.L.; King, D.

    1995-01-01

    Winter and summer indoor radon measurements are reported for 121 houses in Freehold, New Jersey. When presented as winter:summer ratios of indoor radon, the data closely approximate a lognormal distribution. The geometric mean is 1.49. Freehold is located on the fairly flat coastal plain. The winter:summer ratios are believed to represent the norm for regions of the U.S. with cold winters and hot summers. The Freehold data set can be compared to corresponding data sets from other locations to suggest seasonal perturbations of indoor radon arising from unusual causes

  2. Antimicrobial Treatments of Indoor Mold and Bacteria

    Science.gov (United States)

    Biological contaminants especially mold in buildings are known to act as sources of indoor air pollution, discomfort, asthma and pulmonary disease to building occupants. Sick buildings are evidence of extremely problematic indoor air quality (IAQ), often resulting from unacceptab...

  3. Very volatile organic compounds: An understudied class of indoor air pollutants: Keynote: Indoor Air 2014

    OpenAIRE

    Salthammer, T.

    2016-01-01

    Very volatile organic compounds (VVOCs), as categorized by the WHO, are an important subgroup of indoor pollutants and cover a wide spectrum of chemical substances. Some VVOCs are components of products commonly used indoors, some result from chemical reactions and some are reactive precursors of secondary products. Nevertheless, there is still no clear and internationally accepted definition of VVOCs. Current approaches are based on the boiling point, and the saturation vapor pressure or ref...

  4. Redox?Reversible Iron Orthovanadate Cathode for Solid Oxide Steam Electrolyzer

    OpenAIRE

    Gan, Lizhen; Ye, Lingting; Ruan, Cong; Chen, Shigang; Xie, Kui

    2015-01-01

    A redox?reversible iron orthovanadate cathode is demonstrated for a solid oxide electrolyser with up to 100% current efficiency for steam electrolysis. The iron catalyst is grown on spinel?type electronic conductor FeV2O4 by in situ tailoring the reversible phase change of FeVO4 to Fe+FeV2O4 in a reducing atmosphere. Promising electrode performances have been obtained for a solid oxide steam electrolyser based on this composite cathode.

  5. Education of indoor enviromental engineering technology

    Czech Academy of Sciences Publication Activity Database

    Kic, P.; Zajíček, Milan

    2011-01-01

    Roč. 9, Spec. 1 (2011), s. 83-90 ISSN 1406-894X. [Biosystems Engineering 2011. Tartu, 12.05.2011-13.05.2011] Institutional research plan: CEZ:AV0Z10750506 Keywords : Biosystems engineering * indoor environment * study * programs Subject RIV: AM - Education http://library.utia.cas.cz/separaty/2011/VS/zajicek-education of indoor enviromental engineering technology.pdf

  6. In search of the comfortable indoor environment: A comparison of the utility of objective and subjective indicators of indoor comfort

    Energy Technology Data Exchange (ETDEWEB)

    Fransson, Niklas; Skoog, Jennie [Building Services Engineering, Department of Energy and Environment, Chalmers University of Technology, Gothenburg (Sweden); Vaestfjaell, Daniel [Department of Psychology, Goeteborg University (Sweden)

    2007-05-15

    Today, many procedures for assessing the indoor environment rely on both subjective and objective indicators (e.g. ANSI/ASHRAE 55-2004; ISO 10551). It is however unclear how these two types of measurements are related to perceived comfort. This article aims at assessing the relative utility of subjective (rating scale measures) and objective indicators of perceived comfort of indoor environments. In a hospital setting, physical environmental variables (e.g. temperature, relative humidity and noise level) were simultaneously measured as respondents (both patients and staff) rated their perception of the indoor environment. Regression analyses indicated that the subjective sensory ratings were significantly better than objective indicators at predicting overall rated indoor comfort. These results are discussed in relation to existing measurement procedures and standards. (author)

  7. Assessment of the impact of oxidation processes on indoor air pollution using the new time-resolved INCA-Indoor model

    Science.gov (United States)

    Mendez, Maxence; Blond, Nadège; Blondeau, Patrice; Schoemaecker, Coralie; Hauglustaine, Didier A.

    2015-12-01

    INCA-Indoor, a new indoor air quality (IAQ) model, has been developed to simulate the concentrations of volatile organic compounds (VOC) and oxidants considering indoor air specific processes such as: emission, ventilation, surface interactions (sorption, deposition, uptake). Based on the detailed version of SAPRC-07 chemical mechanism, INCA-Indoor is able to analyze the contribution of the production and loss pathways of key chemical species (VOCs, oxidants, radical species). The potential of this model has been tested through three complementary analyses: a comparison with the most detailed IAQ model found in the literature, focusing on oxidant species; realistic scenarios covering a large range of conditions, involving variable OH sources like HONO; and the investigation of alkenes ozonolysis under a large range of indoor conditions that can increase OH and HO2 concentrations. Simulations have been run changing nitrous acid (HONO) concentrations, NOx levels, photolysis rates and ventilation rates, showing that HONO can be the main source of indoor OH. Cleaning events using products containing D-limonene have been simulated at different periods of the day. These scenarios show that HOX concentrations can significantly increase in specific conditions. An assessment of the impact of indoor chemistry on the potential formation of secondary species such as formaldehyde (HCHO) and acetaldehyde (CH3CHO) has been carried out under various room configuration scenarios and a study of the HOx budget for different realistic scenarios has been performed. It has been shown that, under the simulation conditions, formaldehyde can be affected by oxidant concentrations via chemical production which can account for more than 10% of the total production, representing 6.5 ppb/h. On the other hand, acetaldehyde production is affected more by oxidation processes. When the photolysis rates are high, chemical processes are responsible for about 50% of the total production of

  8. Role of dust alkalinity in acid mobilization of iron

    OpenAIRE

    A. Ito; Y. Feng

    2010-01-01

    Atmospheric processing of mineral aerosols by acid gases (e.g., SO2, HNO3, N2O5, and HCl) may play a key role in the transformation of insoluble iron (Fe in the oxidized or ferric (III) form) to soluble forms (e.g., Fe(II), inorganic soluble species of Fe(III), and organic complexes of iron). On the other hand, mineral dust particles have a potential of neutralizing the acidic species due to the alkali...

  9. Indoor Chemistry: Materials, Ventilation Systems, and Occupant Activities

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, G.C.; Corsi, R.L.; Destaillats, H.; Nazaroff, W.W.; Wells, J.R.

    2006-05-01

    Chemical processes taking place in indoor environments can significantly alter the nature and concentrations of pollutants. Exposure to secondary contaminants generated in these reactions needs to be evaluated in association with many aspects of buildings to minimize their impact on occupant health and well-being. Focusing on indoor ozone chemistry, we describe alternatives for improving indoor air quality by controlling chemical changes related to building materials, ventilation systems, and occupant activities.

  10. Allegheny County Clean Indoor Air Act Exemptions

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — List and location of all the businesses and social clubs who have received an exemption from the Pennsylvania Clean Indoor Air Act. “The Clean Indoor Air Act, Act...

  11. Iron and stony-iron meteorites

    DEFF Research Database (Denmark)

    Ruzicka, Alex M.; Haack, Henning; Chabot, Nancy L.

    2017-01-01

    By far most of the melted and differentiated planetesimals that have been sampled as meteorites are metal-rich iron meteorites or stony iron meteorites. The parent asteroids of these meteorites accreted early and differentiated shortly after the solar system formed, producing some of the oldest...... and interpretations for iron and stony iron meteorites (Plate 13.1). Such meteorites provide important constraints on the nature of metal-silicate separation and mixing in planetesimals undergoing partial to complete differentiation. They include iron meteorites that formed by the solidification of cores...... (fractionally crystallized irons), irons in which partly molten metal and silicates of diverse types were mixed together (silicate-bearing irons), stony irons in which partly molten metal and olivine from cores and mantles were mixed together (pallasites), and stony irons in which partly molten metal...

  12. Variations of radon volume activities in soil and indoor air and their correlation

    International Nuclear Information System (INIS)

    Mojzes, A.

    1998-01-01

    Some manual measurements of volume activity of 222 Rn ai soil air and in indoor air of building together with parallel measurements of some meteorological parameters (temperature, humidity and pressure) of both atmospheric and indoor air were carried out. The measurements were performed in the building of Faculty and in its subsoil which consists of slope loams of the base of SW slopes of granitic Male Karpaty Mountains in the area of confluence of the Vidrica Creek with an arm of the Donau river. The monitoring measurements lasted form more than one and a half year, from January 1977 to August 1998, with the frequency of approximately once a week in each object. The soil air was taken from a permanently set up and sealed pipe from the depth of 0.8 m which was placed approximately 10 m from the building at the open air. All measurements of 222 Rn volume activities were performed with a portable fully automatic scintillation detector based on exchangeable Lucas cells. There were also performed the parallel measurements of some meteorological parameters (temperature, humidity and pressure) of air in each object. The geological basement of building is a source of indoor radon. The volume activities of soil 222 Rn range from about 2 kBq/m 3 to about 20 kBq/m 3 with the average of 9.26 kBq/m 3 and the standard deviation of 2.95 kBq/m 3 . The volume activities of indoor air in basement room were form 150 Bq/m 3 to 225 Bq/m 3 and on the third story they were from 125 Bq/m 3 to 175 Bq/m 3 (approximately). The results of monitoring measurements during 20 months period point out the intensity of interaction of geological substrate with building interior through the values of the volume activity of 222 Rn. Therefore a method of building foundation is one of the most important factors which determines the quantity of radon in indoor air. In the light of quality, the fluctuation of radon presence in the bottom part of the buildings is strongly determined by the variations of

  13. Indoor Air Pollution

    Science.gov (United States)

    We usually think of air pollution as being outdoors, but the air in your house or office could also be polluted. Sources of indoor pollution include Mold and pollen Tobacco smoke Household products ...

  14. ABOUT THE SUBDIVISION OF INDOOR SPACES IN INDOORGML

    Directory of Open Access Journals (Sweden)

    A. A. Diakité

    2017-10-01

    Full Text Available Boosted by the dynamic urbanization of cities, indoor environments are getting more and more complex in order to be able to host people properly. While most of our time is spent inside buildings, the need of GIS tools to assist our daily activities that can become tedious, such as indoor navigation or facility management, became more and more urgent. In that perspective, the IndoorGML standard is aiming to address the gaps left by other standards regarding the spatial modelling for indoor navigation. It includes several concepts such as the organization of the spaces into cells along with their network representation and the possibility to represent multiple connected layers. However, being at its first stage, several concepts of the standard could be improved. One of these is the cell subspacing that is not enough discussed in the current version of the standard. In this paper, we explore all the aspects involved in the subdivision process, from the identification of the navigable and non-navigable space cells to the generation of a navigation graph. We propose several criteria on which the indoor sub-spacing can rely to be automatically performed and and illustrate them on a 3D indoor model.

  15. Health effects and sources of indoor air pollution. Part I

    International Nuclear Information System (INIS)

    Samet, J.M.; Marbury, M.C.; Spengler, J.D.

    1987-01-01

    Since the early 1970s, the health effects of indoor air pollution have been investigated with increasing intensity. Consequently, a large body of literature is now available on diverse aspects of indoor air pollution: sources, concentrations, health effects, engineering, and policy. This review begins with a review of the principal pollutants found in indoor environments and their sources. Subsequently, exposure to indoor air pollutants and health effects are considered, with an emphasis on those indoor air quality problems of greatest concern at present: passive exposure to tobacco smoke, nitrogen dioxide from gas-fueled cooking stoves, formaldehyde exposure, radon daughter exposure, and the diverse health problems encountered by workers in newer sealed office buildings. The review concludes by briefly addressing assessment of indoor air quality, control technology, research needs, and clinical implications. 243 references

  16. Laser-Based and Ultra-Portable Gas Sensor for Indoor and Outdoor Formaldehyde (HCHO) Monitoring

    Science.gov (United States)

    Shutter, J. D.; Allen, N.; Paul, J.; Thiebaud, J.; So, S.; Scherer, J. J.; Keutsch, F. N.

    2017-12-01

    While used as a key tracer of oxidative chemistry in the atmosphere, formaldehyde (HCHO) is also a known human carcinogen and is listed and regulated by the United States EPA as a hazardous air pollutant. Combustion processes and photochemical oxidation of volatile organic compounds (VOCs) are the major outdoor sources of HCHO, and building materials and household products are ubiquitous sources of indoor HCHO. Due to the ease with which humans can be exposed to HCHO, it is imperative to monitor levels of both indoor and outdoor HCHO exposure in both short and long-term studies.High-quality direct and indirect methods of quantifying HCHO mixing ratios exist, but instrument size and user-friendliness can make them cumbersome or impractical for certain types of indoor and long-term outdoor measurements. In this study, we present urban HCHO measurements by using a new, commercially-available, ppbv-level accurate HCHO gas sensor (Aeris Technologies' MIRA Pico VOC Laser-Based Gas Analyzer) that is highly portable (29 cm x 20 cm x 10 cm), lightweight (3 kg), easy-to-use, and has low power (15 W) consumption. Using an ultra-compact multipass cell, an absorption path length of 13 m is achieved, resulting in a sensor capable of achieving ppbv/s sensitivity levels with no significant spectral interferences.To demonstrate the utility of the gas sensor for emissions measurements, a GPS was attached to the sensor's housing in order to map mobile HCHO measurements in real-time around the Boston, Massachusetts, metro area. Furthermore, the sensor was placed in residential and industrial environments to show its usefulness for indoor and outdoor pollution measurements. Lastly, we show the feasibility of using the HCHO sensor (or a network of them) in long-term monitoring stations for hazardous air pollutants.

  17. HREM investigation of the constitution and the crystallography of thin thermal oxide layers on iron

    DEFF Research Database (Denmark)

    Graat, P.C.J.; Brongers, M.P.H.; Zandbergen, H.W.

    1997-01-01

    Oxide layers formed at 573 K in O2 at atmospheric pressure, both on a clean iron surface and on an iron surface covered with an etching induced (hydro)oxide film, were investigated with high-resolution transmission electron microscopy (HREM). Cross-sections of oxidised samples were prepared by a ...

  18. Microbiological assessment of indoor air of teaching hospital wards ...

    African Journals Online (AJOL)

    Thus, the objective of this study is to provide fundamental data related to the microbial quality of indoor air of Jimma University Specialized Hospital wards, to estimate the health hazard and to create standards for indoor air quality control. METHODS: The microbial quality of indoor air of seven wards of Jimma University ...

  19. Characterization of indoor bioaerosols from a hospital ward in a ...

    African Journals Online (AJOL)

    Characterization of indoor bioaerosols from a hospital ward in a tropical ... assessment of indoor air quality and determine pathogenic microorganisms due to particle fall-out. Key words: Indoor air, bioaerosols, hospital ward, tropical setting ...

  20. A Study on Public Opinion Poll and Policy on Indoor Air Pollution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K.S.; Lee, H.S.; Kong, S.Y.; Ku, H.J. [Korea Environment Institute, Seoul (Korea)

    2001-12-01

    The purpose of this study is to review previous studies on indoor air pollution and to propose national strategies and policy measures for protecting public health from indoor air pollution based on the results of public survey research. Indoor air has the potential to be polluted by hazardous materials that might lead to serious health problems. It is well known that the indoor spaces are more polluted than outdoor ones, which can be a major health problem for those that live in urban areas who spend most of their time indoors. In Korea, studies on indoor air pollution are usually conducted under the auspices of academic research, which only focus on particular types of indoor spaces and certain concepts of indoor air quality. Thus, at present, the studies on the policies or policy measures concerning indoor air quality management are difficult to find in the country. The governmental agencies that are presently involved in the management of indoor air quality include: the Ministry of Health and Welfare, Ministry of Construction and Transportation, Ministry of Education and Human Resources Development, and Ministry of Environment. However, due to differing regulatory standards between the concerned agencies, the national management of indoor air quality has so far proven to be ineffective. Although the Ministry of Environment recently proposed a law to manage indoor air quality, it is only focuses on managing particular types of indoor spaces not regulated by other governmental bodies and is not effective in the effort towards a national managing system for indoor air pollution. According to a survey conducted by the Korea Environment Institute (KEI), the residents of the Seoul metropolitan area have been felt that environmental pollution negatively affects their health, and especially consider outdoor air pollution to be the most harmful type of pollution. Although these urban residents spend more than 20 hours a day indoors, the survey shows that they do not

  1. Decoupling of Neoarchean sulfur sources recorded in Algoma-type banded iron formation

    Science.gov (United States)

    Diekrup, David; Hannington, Mark D.; Strauss, Harald; Ginley, Stephen J.

    2018-05-01

    Neoarchean Algoma-type banded iron formations (BIFs) are widely viewed as direct chemical precipitates from proximal volcanic-hydrothermal vents. However, a systematic multiple sulfur isotope study of oxide-facies BIF from a type locality in the ca. 2.74 Ga Temagami greenstone belt reveals mainly bacterial turnover of atmospheric elemental sulfur in the host basin rather than deposition of hydrothermally cycled seawater sulfate or sulfur from direct volcanic input. Trace amounts of chromium reducible sulfur that were extracted for quadruple sulfur isotope (32S-33S-34S-36S) analysis record the previously known mass-independent fractionation of volcanic SO2 in the Archean atmosphere (S-MIF) and biological sulfur cycling but only minor contributions from juvenile sulfur, despite the proximity of volcanic sources. We show that the dominant bacterial metabolisms were iron reduction and sulfur disproportionation, and not sulfate reduction, consistent with limited availability of organic matter and the abundant ferric iron deposited as Fe(OH)3. That sulfur contained in the BIF was not a direct volcanic-hydrothermal input, as expected, changes the view of an important archive of the Neoarchean sulfur cycle in which the available sulfur pools were strongly decoupled and only species produced photochemically under anoxic atmospheric conditions were deposited in the BIF-forming environment.

  2. HVAC design guidelines for effective indoor air quality

    International Nuclear Information System (INIS)

    Bladykas, M.P.

    1993-01-01

    Building owners, designers and occupants need to consider all the design measures that contribute to high indoor air quality. Building occupants, furnishings, equipment, and ambient air pollution all contribute to surmounting indoor air quality concerns. However, these can be minimized by following HVAC design guidelines which promote high indoor air quality while maintaining reasonable energy-efficiency. The possible liabilities and loss of business productivity due to air quality problems are too great to ignore

  3. ASSOCIATIONS BETWEEN SEASONAL SLEEP CHANGE AND INDOOR TANNING1,2

    OpenAIRE

    CULNAN, ELIZABETH; KLOSS, JACQUELINE D.; DARLOW, SUSAN; HECKMAN, CAROLYN J.

    2015-01-01

    Identification of risk factors for indoor tanning may ultimately aid the development of better indoor tanning prevention strategies, which is pertinent given the association between indoor tanning and skin cancer. This study aimed to examine the relationship between seasonal sleep change and indoor tanning. Women tanners (N= 139) completed self-report measures including items relating to seasonal sleep changes, seasonal affective disorder (SAD), reasons for tanning, tanning during the winter ...

  4. [Indoor air pollution in southeast Santiago, Chile].

    Science.gov (United States)

    Pino, P; Oyarzún, M; Walter, T; von Baer, D; Romieu, I

    1998-04-01

    Indoor air pollution could play an important role in the susceptibility to respiratory diseases of vulnerable individuals, such as elders and infants. To evaluate indoor air pollution in a low income population of South East Santiago. A domiciliary survey of contaminant sources was carried out in the bouses of a cohort of 522 children less than one year old. Using a case-control design, 121 children consulting for respiratory diseases were considered as cases and 131 healthy infants of the same age and sex were considered as controls. In the houses of both groups, active monitors for particulate matter (PM10) and passive monitors for NO2 were installed. Forty two percent of fathers and 30% of mothers were smokers, and in two thirds of the families there was at least one smoker. Eighty five percent used portable heaters in winter. Of these, 77% used kerosene as fuel. Only 27% had water heating appliances. The rest heated water on the kitchen store or on bonfires. Most kitchen stoves used liquid gas as fuel. Twenty four hour PM10 was 109 +/- 3.2 micrograms/m3. Mean indoor and outdoor NO2 in 24 h was 108 +/- 76.3 and 84 +/- 53.6 micrograms/m3 respectively. Indoor NO2 levels were related to the use of heating devices and smoking. No differences in PM10 and NO2 levels were observed between cases and controls. There is a clear relationship between indoor pollution and contaminating sources. Indoor NO2 levels are higher than outdoors.

  5. Indoor climate optimization with limited resources

    DEFF Research Database (Denmark)

    Santos, A.; Gunnarsen, Lars Bo

    This report presents experimental data and models for optimisation of the indoor climate parameters temperature, noise, draught and window opening. Results are based on experiments with human subjects performed in climate chambers at University of the Philippines. The report may assist building...... designers to balance attention and resources between the parameters of the indoor climate when resources are less than optimal....

  6. A Breath of Fresh Air: Addressing Indoor Air Quality

    Science.gov (United States)

    Palliser, Janna

    2011-01-01

    Indoor air pollution refers to "chemical, biological, and physical contamination of indoor air," which may result in adverse health effects (OECD 2003). The causes, sources, and types of indoor air pollutants will be addressed in this article, as well as health effects and how to reduce exposure. Learning more about potential pollutants in home…

  7. Safety assessment of indoor live fire range, May 1989

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1989-05-01

    The following Safety Assessment (SA) pertains to the indoor live fire range (LFR) at EG&G Mound Applied Technology plant. The purpose of the indoor LFR is to conduct training with live ammunition for all designated personnel. The SA examines the risks that are attendant to the operation of an indoor LFR for this purpose.

  8. A model for the biological precipitation of Precambrian iron-formation

    Science.gov (United States)

    Laberge, G. L.

    1986-01-01

    A biological model for the precipitation of Precambrian iron formations is presented. Assuming an oxygen deficient atmosphere and water column to allow sufficient Fe solubility, it is proposed that local oxidizing environments, produced biologically, led to precipitation of iron formations. It is further suggested that spheroidal structures about 30 mm in diameter, which are widespread in low grade cherty rion formations, are relict forms of the organic walled microfossil Eosphaera tylerii. The presence of these structures suggests that the organism may have had a siliceous test, which allowed sufficient rigidity for accumulation and preservation. The model involves precipitation of ferric hydrates by oxidation of iron in the photic zone by a variety of photosynthetic organisms. Silica may have formed in the frustules of silica secreting organisms, including Eosphaera tylerii. Iron formates formed, therefore, by a sediment rain of biologically produced ferric hydrates and silica and other organic material. Siderite and hematite formed diagenetically on basin floors, and subsequent metamorphism produced magnetite and iron silicates.

  9. Radon and aldehyde concentrations in the indoor environment. Final report

    International Nuclear Information System (INIS)

    Moschandreas, D.J.; Rector, H.E.

    1981-04-01

    Findings regarding indoor air contaminants in the energy-efficient residence (EER) in Mt. Airy, Maryland are reported. The objectives of the study were to collect and analyze relevant air quality samples (specifically radon and aldehydes), characterize the indoor air quality with respect to radon and aldehydes, and develop relationships between air infiltration rates and contaminant levels. One-fifth of the measured formaldehyde concentrations were in the range that may cause health concerns. Although indoor temperature and relative humidity affect indoor HCHO concentration, the elevated formaldehyde concentrations were measured under very low air infiltration rates. The data show that ventilation of the indoor air space is somewhat effective in reducing high HCHO concentrations. The operation of the heat exchanger led to an increase of the air infiltration rate which in turn resulted in substantial reduction of formaldehyde concentrations. A considerable number of the collected samples of indoor air displayed radon concentrations at levels higher than 1.0 to 4.0 nCim -3 (assuming an equilibrium factor of 0.5, these radon levels would correspond to working levels above the health guidelines suggested by the US EPA for homes in Florida built on land reclaimed from phosphate mining). As in the case of indoor formaldehyde concentrations, elevated indoor concentrations are substantially reduced when the infiltration rate is increased. The data base shows that the use of the air to air heat exchanger leads to reduction of indoor radon concentration by increasing the residential ventilation rate

  10. Contribution to the study of iron-manganese alloy oxidation in oxygen at high temperatures

    International Nuclear Information System (INIS)

    Olivier, Francoise

    1972-01-01

    This research thesis reports a systematic investigation of the oxidation of three relatively pure iron-manganese alloys in oxygen, under atmospheric pressure, and between 400 and 1000 C, these alloys being annealed as well as work-hardened. It also compares their behaviour with that of non-alloyed iron oxidized under the same conditions. The author describes the experimental techniques and installations, discusses the morphology of oxide films formed under the experimental conditions, discusses the film growth kinetics which is studied by thermogravimetry, proposes interpretations of results, and outlines the influence of manganese addition to iron on iron oxidation

  11. Atmospheric composition and micro-climate in the Alhambra monument, Granada (Spain), in the context of preventive conservation

    Science.gov (United States)

    Horemans, B.; Schalm, O.; De Wael, K.; Cardell, C.; Van Grieken, R.

    2012-07-01

    The world famous Alhambra monument in Granada, Southern Spain, listed as UNESCO world cultural heritage since 1984, represents probably the most beautiful example of Islamic art and architecture from the Middle Ages in Europe. It is visited by ca. 2 million people annually. Granada is situated in a natural basin, surrounded by mountains with altitudes up to 3500 m. Due to this topography and the prevailing low wind speeds, pollution-derived and especially traffic-derived particulate matter often accumulates in the urban air. In order to evaluate the potential conservation risks from the surrounding air, the atmospheric composition in the Alhambra monument was evaluated. Indoor temperature and relative humidity fluctuations were evaluated for their potential degenerative effects. Furthermore, the atmospheric composition in the Alhambra was analyzed in terms of inorganic gases (NO2, SO2, O3, and NH3) and black carbon. It was found that the open architecture protected the indoor environments from developing a potentially harmful microclimate, such as the build-up of humidity resulting from the huge number of daily tourists. On the downside, the strong ventilation made the indoor air hardly different from outdoor air, as characterized by strong diurnal temperature and relative humidity gradients and high traffic-derived pollutant levels.

  12. Atmospheric composition and micro-climate in the Alhambra monument, Granada (Spain), in the context of preventive conservation

    International Nuclear Information System (INIS)

    Horemans, B; Schalm, O; De Wael, K; Van Grieken, R; Cardell, C

    2012-01-01

    The world famous Alhambra monument in Granada, Southern Spain, listed as UNESCO world cultural heritage since 1984, represents probably the most beautiful example of Islamic art and architecture from the Middle Ages in Europe. It is visited by ca. 2 million people annually. Granada is situated in a natural basin, surrounded by mountains with altitudes up to 3500 m. Due to this topography and the prevailing low wind speeds, pollution-derived and especially traffic-derived particulate matter often accumulates in the urban air. In order to evaluate the potential conservation risks from the surrounding air, the atmospheric composition in the Alhambra monument was evaluated. Indoor temperature and relative humidity fluctuations were evaluated for their potential degenerative effects. Furthermore, the atmospheric composition in the Alhambra was analyzed in terms of inorganic gases (NO 2 , SO 2 , O 3 , and NH 3 ) and black carbon. It was found that the open architecture protected the indoor environments from developing a potentially harmful microclimate, such as the build-up of humidity resulting from the huge number of daily tourists. On the downside, the strong ventilation made the indoor air hardly different from outdoor air, as characterized by strong diurnal temperature and relative humidity gradients and high traffic-derived pollutant levels.

  13. Towards Indoor Transportation Mode Detection using Mobile Sensing

    DEFF Research Database (Denmark)

    Prentow, Thor Siiger; Blunck, Henrik; Kjærgaard, Mikkel Baun

    2015-01-01

    Transportation mode detection is a growing field of research, in which a variety of methods have been developed for detecting transportation modes foremost for outdoor travels. It has been employed in application areas such as public transportation, environmental footprint profiling, and context......-aware mobile assistants. For indoor travels the problem of transportation mode detection has received comparatively little attention, even though diverse transportation modes, such as biking, electric vehicles, and scooters, are used indoors, especially in large building complexes. The potential applications...... are diverse, may also extend beyond indoor variants of the above outdoor applications, and include, e.g., scheduling and progress tracking for mobile workers, management of vehicular resources, and navigation support. However, for indoor transportation mode detection, both the physical environment as well...

  14. Factors influencing indoor concentrations of radon and daughter products

    International Nuclear Information System (INIS)

    Wang Hengde

    1985-01-01

    The correlation between indoor concentrations of 222 Rn and its daughters and some influencing factors is discussed and expressions of concentrations are derived with relation to radon exhalation rate from indoor surfaces, air exchange rate and daughter deposition velocities on indoor surfaces. Experimental methods for determining radon exhalation rate, air exchange rate and daughter deposition velocities are also mentioned

  15. Current implications of past DDT indoor spraying in Oman.

    Science.gov (United States)

    Booij, Petra; Holoubek, Ivan; Klánová, Jana; Kohoutek, Jiří; Dvorská, Alice; Magulová, Katarína; Al-Zadjali, Said; Čupr, Pavel

    2016-04-15

    In Oman, DDT was sprayed indoors during an intensive malaria eradication program between 1976 and 1992. DDT can remain for years after spraying and is associated with potential health risk. This raises the concern for human exposure in areas where DDT was used for indoor spraying. Twelve houses in three regions with a different history of DDT indoor spraying were chosen for a sampling campaign in 2005 to determine p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT), p,p'-dichlorodiphenyldichloroethylene (p,p'-DDE) and p,p'-dichlorodiphenyldichloroethane (p,p'-DDD) levels in indoor air, dust, and outdoor soil. Although DDT was only sprayed indoor, p,p'-DDT, p,p'-DDE and p,p'-DDD were also found in outdoor soil. The results indicate that release and exposure continue for years after cessation of spraying. The predicted cancer risk based on concentrations determined in 2005, indicate that there was still a significant cancer risk up to 13 to 16years after indoor DDT spraying. A novel approach, based on region-specific half-lives, was used to predict concentrations in 2015 and showed that more than 21years after spraying, cancer risk for exposure to indoor air, dust, and outdoor soil are acceptable in Oman for adults and young children. The model can be used for other locations and countries to predict prospective exposure of contaminants based on indoor experimental measurements and knowledge about the spraying time-schedule to extrapolate region-specific half-lives and predict effects on the human population years after spraying. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Indoor Air Quality and Asthma

    Directory of Open Access Journals (Sweden)

    Robert Golden

    2017-02-01

    Full Text Available Numerous contaminants in indoor air and their potential to cause or exacerbate asthma continue to be a subject of public health concern. Many agents are causally associated with or can exacerbate asthma, particularly in children. For formaldehyde, an established respiratory irritant based on numerous studies, the evidence for an association with asthma is still considered only limited or suggestive. However, there is no evidence that indicates increased sensitivity to sensory irritation to formaldehyde in people often regarded as susceptible such as asthmatics. Acrolein, but not formaldehyde, was significantly associated with asthma in a large cohort of children. This prompted an evaluation of this highly irritating chemical that had never previously been considered in the context of the indoor air/childhood asthma issue. Because acrolein is more potent than formaldehyde as a respiratory irritant and ubiquitous in indoor air, it is plausible that previous studies on potential risk factors and childhood asthma may be confounded by formaldehyde acting as an unrecognized proxy for acrolein.

  17. EML indoor radon workshop, 1982

    International Nuclear Information System (INIS)

    George, A.C.; Lowder, W.; Fisenne, I.; Knutson, E.O.; Hinchliffe, L.

    1983-07-01

    A workshop on indoor radon, held at the Environmental Measurements Laboratory (EML) on November 30 and December 1, 1982, covered recent developments in radon daughter research and development. Thirty papers were presented dealing with standardization and quality assurance measurement methods, surveys, measurements strategy, physical mechanisms of radon and radon daughter transport and development of guidance standards for indoor exposures. The workshop concluded with a planning session that identified the following needs: (1) national and international intercomparisons of techniques for measuring radon and radon daughter concentrations, working level and radon exhalation flux density; (2) development and refinement of practical measurement techniques for thoron and its daughter products; (3) quantitative definition of the sources of indoor radon and the mechanisms of transport into structures; (4) better knowledge of the physical properties of radon daughters; (5) more complete and accurate data on the population exposure to radon, which can only be met by broadly based surveys; and (6) more international cooperation and information exchange among countries with major research programs

  18. Manual on indoor air quality

    International Nuclear Information System (INIS)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues

  19. Manual on indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues.

  20. The effects of vegetation on indoor thermal comfort

    DEFF Research Database (Denmark)

    Pastore, Luisa; Corrao, Rossella; Heiselberg, Per Kvols

    2017-01-01

    Highlights •A multi-scale simulation methodology to assess the effects of vegetation on thermal comfort is used. •It application is shown on a case of urban and building retrofit intervention. •The effect of plants on the microclimate and indoor environment is assessed. •A decrease of up to 4.8 °C...... in indoor temperature is registered. •The final impact on the indoor thermal comfort based on the adaptive model is determined....

  1. Light fidelity (LI-FI) based indoor communication system

    OpenAIRE

    Aftab, Farooq; khan, Muhammad Nafees Ulfat; Ali, Shahzad

    2016-01-01

    Indoor wireless communication is an essential part of next generation wireless communication system.For an indoor communication number of users and their device are increasing very rapidly so as a result capacity of frequency spectrum to accommodate further users in future is limited and also it would be difficult for service providers to provide more user reliable and high speed communication so this short come can be solve in future by using Li-Fi based indoor communication syst...

  2. Evaluation of the Indoor Environment in the Comfort Houses

    DEFF Research Database (Denmark)

    Brunsgaard, Camilla; Heiselberg, Per; Knudstrup, Mary-Ann

    2012-01-01

    and in a process of doing so, it is important to maintain a good and healthy indoor environment and not on the expense of it. One way of saving energy is to build passive houses. This paper presents the result of a case study of some of the first certified passive houses in Denmark, called the Comfort Houses....... The paper evaluates the indoor environment through both quantitative measurements in the houses and qualitative interviews with the occupants about their experiences of the indoor environment. Two set of knowledge which together gives a more complete and holistic picture of the indoor environment. The study...

  3. EVALUATION OF AIR PURIFICATION DEVICES FOR CONTROL OF INDOOR PM

    Science.gov (United States)

    Because people spend most of their time indoors (89%), the indoor environment is a primary determinant of particle exposure. The indoor environment is especially an important determinant for the very young, the very old, and those with underlying cardiopulmonary disease because...

  4. CFD simulation research on residential indoor air quality.

    Science.gov (United States)

    Yang, Li; Ye, Miao; He, Bao-Jie

    2014-02-15

    Nowadays people are excessively depending on air conditioning to create a comfortable indoor environment, but it could cause some health problems in a long run. In this paper, wind velocity field, temperature field and air age field in a bedroom with wall-hanging air conditioning running in summer are analyzed by CFD numerical simulation technology. The results show that wall-hanging air conditioning system can undertake indoor heat load and conduct good indoor thermal comfort. In terms of wind velocity, air speed in activity area where people sit and stand is moderate, most of which cannot feel wind flow and meet the summer indoor wind comfort requirement. However, for air quality, there are local areas without ventilation and toxic gases not discharged in time. Therefore it is necessary to take effective measures to improve air quality. Compared with the traditional measurement method, CFD software has many advantages in simulating indoor environment, so it is hopeful for humans to create a more comfortable, healthy living environment by CFD in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. The right to healthy indoor air: Status by 2002

    DEFF Research Database (Denmark)

    Mølhave, Lars; Krzyzanowski, M.

    2003-01-01

    . The discussions and statements are available as a WHO report. It informs the individuals and groups responsible for healthy indoor air about their rights and obligations, and empowers the general public by making people familiar with those rights. One year after their publication the statements have been adopted......One of the reasons for the inadequate quality of indoor air arises from the poor articulation, appreciation and understanding of basic principles underlying the policies and actions related to indoor air quality. A WHO Working Group derived nine statements on rights to healthy indoor air...... as the base for future regulation and guidance. The Board of Directors of the International Society of Indoor Air Quality (ISIAQ) and the participants of two international conferences endorse the use of the statements. No opposition to the statements have been registered. The statements have entered curricula...

  6. Status of the indoor climate labelling scheme in Denmark

    DEFF Research Database (Denmark)

    Witterseh, Thomas

    2002-01-01

    The impartial Indoor Climate Labelling, ICL, originally introduced in Denmark to reduce emissions from building materials and products used in the indoor environment, is still developing and consolidating its position. The ICL benefits from an expansion of the product areas covered and a still...... increasing number of labelled products. The product area of furniture is now included, making a total of ten different product areas. Approximately 100 different groups of products are included, which individually covers a number of specific products. An increasing number of manufacturers apply...... for the Indoor Climate Label, due to a growing concern about the indoor environment among architects, consulting and planning engineers and private consumers. This shows that the concept is now working as originally intended. A goal for the ICL is to develop a method for labelling of the overall indoor...

  7. Occurrence, dynamics and reactions of organic pollutants in the indoor environment

    Energy Technology Data Exchange (ETDEWEB)

    Salthammer, Tunga [Material Analysis and Indoor Chemistry, Fraunhofer Wilhelm-Klauditz Institut (WKI), Braunschweig (Germany); Bahadir, Muefit [Institut fuer Oekologische Chemie und Abfallanalytik, Technische Universitaet Braunschweig, Braunschweig (Germany)

    2009-06-15

    The indoor environment is a multidisciplinary scientific field involving chemistry, physics, biology, health sciences, architecture, building sciences and civil engineering. The need for reliable assessment of human exposure to indoor pollutants is attracting increasing attention. This, however, requires a detailed understanding of the relevant compounds, their sources, physical and chemical properties, dynamics, reactions, their distribution among the gas phase, airborne particles and settled dust as well as the availability of modern measurement techniques. Building products, furnishings and other indoor materials often emit volatile and semi-volatile organic compounds. With respect to a healthy indoor environment, only low emitting products, which do not influence indoor air quality in a negative way, should be used in a building. Therefore, materials and products for indoor use need to be evaluated for their chemical emissions. This is routinely done in test chambers and cells. Many studies have shown that the types of sources in occupational and residential indoor environments, the spectrum of emitting compounds and the duration of emission cover a wide range. The demand for standardized test methods under laboratory conditions has resulted in several guidelines for determination of emission rates. Furthermore, it has now been recognized that both primary and secondary emissions may affect indoor air quality. The problem may become more dominant when components of different materials can react with each other or when catalytic materials are applied. Such products derived from indoor related reactions may have a negative impact on indoor air quality due to their low odor threshold, health related properties or the formation of ultrafine particles. Several factors can influence the emission characteristics and numerous investigations have shown that indoor chemistry is of particular importance for the indoor related characterization of building product emissions

  8. Investigation on Moisture and Indoor Environment in Eight Danish Houses

    DEFF Research Database (Denmark)

    Jensen, Kasper Risgaard; Jensen, Rasmus Lund; Nørgaard, Jesper

    2011-01-01

    then need to be ventilated actively either by natural or mechanical ventilation. Increased focus on energy reduction together with requirements for e.g. thermal comfort indoors may lead to reduced indoor air quality and moisture problems which in turn may cause mould problems. This paper describes...... an investigation of the indoor air quality, relative humidity and air change rate in eight Danish houses. The houses were selected as they are all having recurrent problems with condensation on the windows. The houses were built between 1930 and 2007. Some of them have been only slightly renovated where others......, to indoor air quality in terms of CO2 concentration, and to the use of the house in terms of the level of the relative humidity and indoor moisture excess. Furthermore, the moisture production in the houses was estimated and compared to values provided in the literature. A better indoor air quality...

  9. Indoor environmental health

    CSIR Research Space (South Africa)

    Parsons, S

    2010-01-01

    Full Text Available Indoor Environmental Health (IEH) is a comprehensive term that includes the effects of quantity of air, light and noise in a space and the physical, physiological and psychological aspects from colours, aesthetics, services, outdoor climate...

  10. Indoor environmental health

    CSIR Research Space (South Africa)

    Parsons, SA

    2010-04-01

    Full Text Available Indoor Environmental Health (IEH) is a comprehensive term that includes the effects of quantity of air, light and noise in a space and the physical, physiological and psychological aspects from colours, aesthetics, services, outdoor climate...

  11. Diversity and taxonomy of Chaetomium and chaetomium-like fungi from indoor environments

    Directory of Open Access Journals (Sweden)

    X.W. Wang

    2016-06-01

    Full Text Available During a study of indoor fungi, 145 isolates belonging to Chaetomiaceae were cultured from air, swab and dust samples from 19 countries. Based on the phylogenetic analyses of DNA-directed RNA polymerase II second largest subunit (rpb2, β-tubulin (tub2, ITS and 28S large subunit (LSU nrDNA sequences, together with morphological comparisons with related genera and species, 30 indoor taxa are recognised, of which 22 represent known species, seven are described as new, and one remains to be identified to species level. In our collection, 69 % of the indoor isolates with six species cluster with members of the Chaetomium globosum species complex, representing Chaetomium sensu stricto. The other indoor species fall into nine lineages that are separated from each other with several known chaetomiaceous genera occurring among them. No generic names are available for five of those lineages, and the following new genera are introduced here: Amesia with three indoor species, Arcopilus with one indoor species, Collariella with four indoor species, Dichotomopilus with seven indoor species and Ovatospora with two indoor species. The generic concept of Botryotrichum is expanded to include Emilmuelleria and the chaetomium-like species B. muromum (= Ch. murorum in which two indoor species are included. The generic concept of Subramaniula is expanded to include several chaetomium-like taxa as well as one indoor species. Humicola is recognised as a distinct genus including two indoor taxa. According to this study, Ch. globosum is the most abundant Chaetomiaceae indoor species (74/145, followed by Ch. cochliodes (17/145, Ch. elatum (6/145 and B. piluliferum (5/145. The morphological diversity of indoor Chaetomiaceae as well as the morphological characteristics of the new genera are described and illustrated. This taxonomic study redefines the generic concept of Chaetomium and provides new insight into the phylogenetic relationships among different genera within

  12. Bluetooth Indoor Positioning System using Fingerprinting

    DEFF Research Database (Denmark)

    Frost, Christian; Jensen, Casper Svenning; Luckow, Kasper Søe

    2011-01-01

    Indoor Positioning has been an active research area in the last decade, but so far, commercial Indoor Positioning Systems (IPSs) have been sparse. The main obstacle towards widely available IPSs has been the lack of appropriate, low cost technologies, that enable indoor positioning. While Wi-Fi...... infrastructures are ubiquitous, consumer-oriented Wi-Fi enabled mobile phones have been missing. Conversely, while Bluetooth technology is present in the vast majority of consumer mobile phones, Bluetooth infrastructures have been missing. Bluetooth infrastructures have typically been installed as part...... of complete hardware/software IPSs that often incur a substantial hardware cost. Furthermore, Bluetooth has low power consumption compared to Wi-Fi devices, which promotes longer battery life-time on mobile phones. In this paper, we present a Bluetooth IPS based entirely on commodity-grade products...

  13. Indoor radon levels in coastal Karnataka

    International Nuclear Information System (INIS)

    Narayana, Y.; Radhakrishna, A.P.; Somashekarappa, H.M.; Karunakara, N.; Balakrishna, K.M.; Siddappa, K.

    1995-01-01

    Indoor radon levels have been measured in selected dwellings of coastal Karnataka using LR-115 type II peelable films and it is found to vary from 28.4 to 45.6 Bq m -3 with a geometric mean value of 35.7 Bq m -3 . The annual effective dose equivalent to the population of the region due to inhalation of radon was estimated from the measured data on radon level and is found to be in the range 1.9 - 3.1 mSv y -1 with a mean value 2.4 mSv y -1 . The correlation between indoor radon level and radium content in the underlying soil were studied. No definite correlation was observed to exist between indoor radon level and radium content in soil. (author). 24 refs., 2 tabs

  14. Indoor air quality at nine shopping malls in Hong Kong.

    Science.gov (United States)

    Li, W M; Lee, S C; Chan, L Y

    2001-06-12

    Hong Kong is one of the most attractive shopping paradises in the world. Many local people and international tourists favor to spend their time in shopping malls in Hong Kong. Good indoor air quality is, therefore, very essential to shoppers. In order to characterize the indoor air quality in shopping malls, nine shopping malls in Hong Kong were selected for this study. The indoor air pollutants included carbon dioxide (CO2), carbon monoxide (CO), total hydrocarbons (THC), formaldehyde (HCHO), respirable particulate matter (PM10) and total bacteria count (TBC). More than 40% of the shopping malls had 1-h average CO2 levels above the 1000 ppm of the ASHRAE standard on both weekdays and weekends. Also, they had average weekday PM10 concentrations that exceeded the Hong Kong Indoor Air Quality Objective (HKIAQO). The highest indoor PM10 level at a mall was 380 microg/m3. Of the malls surveyed, 30% had indoor airborne bacteria levels above 1000 cfu/m3 set by the HKIAQO. The elevated indoor CO2 and bacteria levels could result from high occupancy combined with insufficient ventilation. The increased PM10 levels could be probably attributed to illegal smoking inside these establishments. In comparison, the shopping malls that contained internal public transport drop-off areas, where vehicles were parked with idling engines and had major entry doors close to heavy traffic roads had higher CO and PM10 indoor levels. In addition, the extensive use of cooking stoves without adequate ventilation inside food courts could increase indoor CO2, CO and PM10 levels.

  15. Indoor Air Quality Building Education and Assessment Model

    Science.gov (United States)

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM), released in 2002, is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  16. Natural indoor gamma background in Coonoor environment of South India

    International Nuclear Information System (INIS)

    Sivakumar, R.; Selvasekarapandian, S.; Mugunthamanikand, N.; Raghunath, V.M.

    2002-01-01

    Indoor natural radiation dose existing in dwellings of Coonoor have been estimated using thermoluminescent dosimeters. TLDs are displayed in indoors and are replaced after three-month period. The seasonal averages of the dose rate and the annual effective dose equivalent are calculated from the measured results. Geographical and seasonal variations as well as the differences between indoor to outdoor dose rates have also been studied. Very good correlation exists between the indoor dose rates measured by LTD and environmental radiation dosimeter with correlation coefficient of 0.91. The annual effective dose equivalent to the Coonoor population due to indoor gamma radiation was estimated to be 970 μSv/y for the period of 1997-1998. (author)

  17. Mechanism of iron catalyzed oxidation of SO/sub 2/ in oxygenated solutions

    Energy Technology Data Exchange (ETDEWEB)

    Freiberg, J

    1975-01-01

    Previous experimental work concerning the iron catalyzed oxidation of SO/sub 2/ in oxygenated acid solutions failed to provide a consistent reaction mechanism and rate expression. As iron is one of the main constituents of urban atmospheric aerosols, the rate studies of heterogeneous sulphate formation in polluted city air were hampered. The present study develops a new theory for the iron catalyzed oxidation of SO/sub 2/. The resulting new rate expression is general enough to account for the results of previous experimental investigations that were performed in different ranges of SO/sub 2/ and catalyst concentrations.

  18. Reducing health risks from indoor exposures in rapidly developing urban China.

    Science.gov (United States)

    Zhang, Yinping; Mo, Jinhan; Weschler, Charles J

    2013-07-01

    Over the past two decades there has been a large migration of China's population from rural to urban regions. At the same time, residences in cities have changed in character from single-story or low-rise buildings to high-rise structures constructed and furnished with many synthetic materials. As a consequence, indoor exposures (to pollutants with outdoor and indoor sources) have changed significantly. We briefly discuss the inferred impact that urbanization and modernization have had on indoor exposures and public health in China. We argue that growing adverse health costs associated with these changes are not inevitable, and we present steps that could be taken to reduce indoor exposures to harmful pollutants. As documented by China's Ministry of Health, there have been significant increases in morbidity and mortality among urban residents over the past 20 years. Evidence suggests that the population's exposure to air pollutants has contributed to increases in lung cancer, cardiovascular disease, pulmonary disease, and birth defects. Whether a pollutant has an outdoor or an indoor source, most exposure to the pollutant occurs indoors. Going forward, indoor exposures can be reduced by limiting the ingress of outdoor pollutants (while providing adequate ventilation with clean air), minimizing indoor sources of pollutants, updating government policies related to indoor pollution, and addressing indoor air quality during a building's initial design. Taking the suggested steps could lead to significant reductions in morbidity and mortality, greatly reducing the societal costs associated with pollutant derived ill health.

  19. Air-Sense: indoor environment monitoring evaluation system based on ZigBee network

    Science.gov (United States)

    Huang, Yang; Hu, Liang; Yang, Disheng; Liu, Hengchang

    2017-08-01

    In the modern life, people spend most of their time indoors. However, indoor environmental quality problems have always been affecting people’s social activities. In general, indoor environmental quality is also related to our indoor activities. Since most of the organic irritants and volatile gases are colorless, odorless and too tiny to be seen, because we have been unconsciously overlooked indoor environment quality. Consequently, our body suffer a great health problem. In this work, we propose Air-Sense system which utilizes the platform of ZigBee Network to collect and detect the real-time indoor environment quality. What’s more, Air-Sense system can also provide data analysis, and visualizing the results of the indoor environment to the user.

  20. Finding dense locations in symbolic indoor tracking data

    DEFF Research Database (Denmark)

    Ahmed, Tanvir; Pedersen, Torben Bach; Lu, Hua

    2017-01-01

    presents two graph-based models for constrained and semi-constrained indoor movement, respectively, and then uses the models to map raw tracking records into mapping records that represent object entry and exit times in particular locations. Subsequently, an efficient indexing structure called Hierarchical...... Dense Location Time Index (HDLT-Index) is proposed for indexing the time intervals of the mapping table, along with index construction, query processing, and pruning techniques. The HDLT-Index supports very efficient aggregate point, interval, and duration queries as well as dense location queries......Finding the dense locations in large indoor spaces is very useful for many applications such as overloaded area detection, security control, crowd management, indoor navigation, and so on. Indoor tracking data can be enormous and are not immediately ready for finding dense locations. This paper...

  1. Indoor environmental health in schools

    Energy Technology Data Exchange (ETDEWEB)

    Small, B.M. [Envirodesic Certification Program, Stouffville, ON (Canada)

    1999-07-01

    Indoor health is a concern today because unhealthy environments can cause adverse health effects, poor learning and teaching and increased costs. The holistic view of the environment and human health links sick kids, absenteeism, teacher illness, education costs and mouldy schools. An historical perspective is provided on the problem and its treatment referring to: 1962 and chemical susceptibility, 1975 and open systems theory, 1978 and high risk groups, 1985 and pollution and education in Toronto, 1987 and health environments for Canadians, 1995 and the National Education Association in the U.S., 1997 and a U.S. Executive Order, 1998 and the Texas Dept. of Health, 1998 and the U.S. EPS website 'IAQ Tools for Schools', and 1998 and 'The air children breathe.' It is known that pollutants adversely affect health, that children are highly susceptible, that the role in schools has being known for decades, and that information is now available worldwide through the Internet. The reasons why mould is a problem are listed, and the effects of an unhealthy indoor environment are referred to. The benefits of a healthy indoor environment are listed, and the various means of creating a healthy indoor environment are outlined. New developments are referred to including: fresh air, building envelope, building leakage, airtightness of buildings, tight envelope and air supply, low-emission materials, maintenance and cleaning, strategy and financing, collaboration, and the possibility of healthy schools.

  2. Alien skies planetary atmospheres from earth to exoplanets

    CERN Document Server

    Pont, Frédéric J

    2014-01-01

    Planetary atmospheres are complex and evolving entities, as mankind is rapidly coming to realise whilst attempting to understand, forecast and mitigate human-induced climate change. In the Solar System, our neighbours Venus and Mars provide striking examples of two endpoints of planetary evolution, runaway greenhouse and loss of atmosphere to space. The variety of extra-solar planets brings a wider angle to the issue: from scorching "hot jupiters'' to ocean worlds, exo-atmospheres explore many configurations unknown in the Solar System, such as iron clouds, silicate rains, extreme plate tectonics, and steam volcanoes. Exoplanetary atmospheres have recently become accessible to observations. This book puts our own climate in the wider context of the trials and tribulations of planetary atmospheres. Based on cutting-edge research, it uses a grand tour of the atmospheres of other planets to shine a new light on our own atmosphere, and its relation with life.

  3. Online Risk Prediction for Indoor Moving Objects

    DEFF Research Database (Denmark)

    Ahmed, Tanvir; Pedersen, Torben Bach; Calders, Toon

    2016-01-01

    Technologies such as RFID and Bluetooth have received considerable attention for tracking indoor moving objects. In a time-critical indoor tracking scenario such as airport baggage handling, a bag has to move through a sequence of locations until it is loaded into the aircraft. Inefficiency or in...... reduce the operation cost....

  4. Exploring the consequences of climate change for indoor air quality

    International Nuclear Information System (INIS)

    Nazaroff, William W

    2013-01-01

    Climate change will affect the concentrations of air pollutants in buildings. The resulting shifts in human exposure may influence public health. Changes can be anticipated because of altered outdoor pollution and also owing to changes in buildings effected in response to changing climate. Three classes of factors govern indoor pollutant levels in occupied spaces: (a) properties of pollutants; (b) building factors, such as the ventilation rate; and (c) occupant behavior. Diversity of indoor conditions influences the public health significance of climate change. Potentially vulnerable subpopulations include not only the young and the infirm but also those who lack resources to respond effectively to changing conditions. Indoor air pollutant levels reflect the sum of contributions from indoor sources and from outdoor pollutants that enter with ventilation air. Pollutant classes with important indoor sources include the byproducts of combustion, radon, and volatile and semivolatile organic compounds. Outdoor pollutants of special concern include particulate matter and ozone. To ensure good indoor air quality it is important first to avoid high indoor emission rates for all pollutants and second to ensure adequate ventilation. A third factor is the use of air filtration or air cleaning to achieve further improvements where warranted. (letter)

  5. Standards for securing adequate indoor air quality across Europe

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Carrer, P.; de Oliveira Fernandes, E.

    2013-01-01

    Background: Inadequate IAQ causes a loss of 2 million healthy life years annually in the EU. Europeans spend typically over 85–90% of their time indoors and the main factors that affect negatively the characteristics of the air they breathe are outdoor air used to ventilate indoor spaces and indoor...... effects of IAQ into different components: exposures to indoor and outdoor air pollutants, association with different morbidities and the way ventilation based approaches could minimise their impact. Disability adjusted life years (DALYs), a common metric to allow comparability of impacts on various types...... and is determined mainly considering the metabolic CO2 production. It is only applicable if all other pollutants meet WHO guidelines for ambient and indoor air quality. If they do not meet these guidelines after applying source control and when air used for ventilation is clean health-based ventilation rate should...

  6. Indoor air quality in public utility environments-a review.

    Science.gov (United States)

    Śmiełowska, Monika; Marć, Mariusz; Zabiegała, Bożena

    2017-04-01

    Indoor air quality has been the object of interest for scientists and specialists from the fields of science such as chemistry, medicine and ventilation system design. This results from a considerable number of potential factors, which may influence the quality of the broadly understood indoor air in a negative way. Poor quality of indoor air in various types of public utility buildings may significantly affect an increase in the incidence of various types of civilisation diseases. This paper presents information about a broad spectrum of chemical compounds that were identified and determined in the indoor environment of various types of public utility rooms such as churches, museums, libraries, temples and hospitals. An analysis of literature data allowed for identification of the most important transport paths of chemical compounds that significantly influence the quality of the indoor environment and thus the comfort of living and the health of persons staying in it.

  7. Advanced airflow distribution methods for reduction of personal exposure to indoor pollutants

    DEFF Research Database (Denmark)

    Cao, Guangyu; Kosonen, Risto; Melikov, Arsen

    2016-01-01

    The main objective of this study is to recognize possible airflow distribution methods to protect the occupants from exposure to various indoor pollutants. The fact of the increasing exposure of occupants to various indoor pollutants shows that there is an urgent need to develop advanced airflow ...... distribution methods to reduce indoor exposure to various indoor pollutants. This article presents some of the latest development of advanced airflow distribution methods to reduce indoor exposure in various types of buildings.......The main objective of this study is to recognize possible airflow distribution methods to protect the occupants from exposure to various indoor pollutants. The fact of the increasing exposure of occupants to various indoor pollutants shows that there is an urgent need to develop advanced airflow...

  8. Indexing the Trajectories of Moving Objects in Symbolic Indoor Space

    DEFF Research Database (Denmark)

    Jensen, Christian Søndergaard; Lu, Hua; Yang, Bin

    2009-01-01

    . This scenario calls for the indexing of indoor trajectories. Based on an appropriate notion of indoor trajectory and definitions of pertinent types of queries, the paper proposes two R-tree based structures for indexing object trajectories in symbolic indoor space. The RTR-tree represents a trajectory as a set......Indoor spaces accommodate large populations of individuals. With appropriate indoor positioning, e.g., Bluetooth and RFID, in place, large amounts of trajectory data result that may serve as a foundation for a wide variety of applications, e.g., space planning, way finding, and security...... for each index. An empirical performance study suggests that the two indexes are effective, efficient, and robust. The study also elicits the circumstances under which our proposals perform the best....

  9. Indoor Environment Program - 1996 Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    Indoor Environment Program

    1996-11-01

    The forty-five chemists, physicists, biologists, architects, engineers, staff, and students of the Indoor Environment Program are all working to solve the problems of indoor air quality, health, comfort, and energy use associated with the indoor environment. A common thread throughout this work is the importance of ventilation--both for its role in supporting human health and comfort as well as for its liability in requiring large amounts of energy to heat and cool it. The importance of understanding these interactions can be illustrated by two examples: the health and productivity of workers (Fisk and Rosenfeld, 1996) and the performance of sensitive equipment in clean room environments (Faulkner, et d., 1996). During the past year, we estimated the magnitudes of health and productivity gains that may be obtained by providing better indoor environments. The ratio of the potential financial benefits of improving indoor environments to the costs of the improvements ranges between 20 and 50. A second example is from our Clean Room Energy Efficiency Study: Clean rooms utilize large amounts of electricity to operate fans that recirculate air at very high flow rates through particle filters. Usually, the fans operate continuously at full speed, even when the clean room is unused. To reduce the energy use in a research clean room, the rate of air recirculation was controlled in response to real-time measurements of particle concentration. With this new control system, fan energy use decreased by 65% to 85% while maintaining particle concentrations below the allowable limits except during occasional one-minute periods. The estimated payback period for this technology is one to four years.

  10. Indoor Temperatures in Low Cost Housing in Johannesburg, South Africa.

    Science.gov (United States)

    Naicker, Nisha; Teare, June; Balakrishna, Yusentha; Wright, Caradee Yael; Mathee, Angela

    2017-11-18

    Ambient and indoor temperature affects thermal comfort and human health. In a changing climate with a predicted change in temperature extremes, understanding indoor temperatures, both hot and cold, of different housing types is important. This study aimed to assess the hourly, daily and monthly variation in indoor temperatures in different housing types, namely formal houses, informal houses, flats, government-built low-cost houses and old, apartheid era low-cost housing, in five impoverished urban communities in Johannesburg, South Africa. During the cross-sectional survey of the Health, Environment and Development study data loggers were installed in 100 homes (20 per suburb) from February to May 2014. Indoor temperature and relative humidity were recorded on an hourly basis. Ambient outdoor temperatures were obtained from the nearest weather station. Indoor and outdoor temperature and relative humidity levels were compared; and an inter-comparison between the different housing types were also made. Apparent temperature was calculated to assess indoor thermal comfort. Data from 59 retrieved loggers showed a significant difference in monthly mean indoor temperature between the five different housing types ( p informal settlement houses had the greatest variation in temperature and experienced temperatures between 4 and 5 °C warmer than outdoor temperatures. Housing types occupied by poor communities experienced indoor temperature fluctuations often greater than that observed for ambient temperatures. Families living in government-built low-cost and informally-constructed homes are the most at risk for indoor temperature extremes. These types of housing should be prioritised for interventions aimed at assisting families to cope with extreme temperatures, gaining optimal thermal comfort and preventing temperature-related health effects.

  11. Indoor Temperatures in Low Cost Housing in Johannesburg, South Africa

    Directory of Open Access Journals (Sweden)

    Nisha Naicker

    2017-11-01

    Full Text Available Ambient and indoor temperature affects thermal comfort and human health. In a changing climate with a predicted change in temperature extremes, understanding indoor temperatures, both hot and cold, of different housing types is important. This study aimed to assess the hourly, daily and monthly variation in indoor temperatures in different housing types, namely formal houses, informal houses, flats, government-built low-cost houses and old, apartheid era low-cost housing, in five impoverished urban communities in Johannesburg, South Africa. During the cross-sectional survey of the Health, Environment and Development study data loggers were installed in 100 homes (20 per suburb from February to May 2014. Indoor temperature and relative humidity were recorded on an hourly basis. Ambient outdoor temperatures were obtained from the nearest weather station. Indoor and outdoor temperature and relative humidity levels were compared; and an inter-comparison between the different housing types were also made. Apparent temperature was calculated to assess indoor thermal comfort. Data from 59 retrieved loggers showed a significant difference in monthly mean indoor temperature between the five different housing types (p < 0.0001. Low cost government-built houses and informal settlement houses had the greatest variation in temperature and experienced temperatures between 4 and 5 °C warmer than outdoor temperatures. Housing types occupied by poor communities experienced indoor temperature fluctuations often greater than that observed for ambient temperatures. Families living in government-built low-cost and informally-constructed homes are the most at risk for indoor temperature extremes. These types of housing should be prioritised for interventions aimed at assisting families to cope with extreme temperatures, gaining optimal thermal comfort and preventing temperature-related health effects.

  12. Risk factors for indoor air pollution in rural households in Mauche ...

    African Journals Online (AJOL)

    Risk factors for indoor air pollution in rural households in Mauche division, Molo ... indoor air pollution, which has been associated with various diseases. Key words: biomass fuel, children, indoor pollution, respiratory infections, ventilation.

  13. Source Apportionment and Influencing Factor Analysis of Residential Indoor PM2.5 in Beijing

    Science.gov (United States)

    Yang, Yibing; Liu, Liu; Xu, Chunyu; Li, Na; Liu, Zhe; Wang, Qin; Xu, Dongqun

    2018-01-01

    In order to identify the sources of indoor PM2.5 and to check which factors influence the concentration of indoor PM2.5 and chemical elements, indoor concentrations of PM2.5 and its related elements in residential houses in Beijing were explored. Indoor and outdoor PM2.5 samples that were monitored continuously for one week were collected. Indoor and outdoor concentrations of PM2.5 and 15 elements (Al, As, Ca, Cd, Cu, Fe, K, Mg, Mn, Na, Pb, Se, Tl, V, Zn) were calculated and compared. The median indoor concentration of PM2.5 was 57.64 μg/m3. For elements in indoor PM2.5, Cd and As may be sensitive to indoor smoking, Zn, Ca and Al may be related to indoor sources other than smoking, Pb, V and Se may mainly come from outdoor. Five factors were extracted for indoor PM2.5 by factor analysis, explained 76.8% of total variance, outdoor sources contributed more than indoor sources. Multiple linear regression analysis for indoor PM2.5, Cd and Pb was performed. Indoor PM2.5 was influenced by factors including outdoor PM2.5, smoking during sampling, outdoor temperature and time of air conditioner use. Indoor Cd was affected by factors including smoking during sampling, outdoor Cd and building age. Indoor Pb concentration was associated with factors including outdoor Pb and time of window open per day, building age and RH. In conclusion, indoor PM2.5 mainly comes from outdoor sources, and the contributions of indoor sources also cannot be ignored. Factors associated indoor and outdoor air exchange can influence the concentrations of indoor PM2.5 and its constituents. PMID:29621164

  14. Environment and development of respiratory allergy. II. Indoors.

    Science.gov (United States)

    D'Amato, G; Liccardi, G; D'Amato, M

    1994-12-01

    Even if it is difficult to obtain correct epidemiological evidence, there is a body of evidence which suggests that the frequency of allergic respiratory diseases is increasing. The majority of atopic patients, in particular in childhood and adolescence, develop immunoglobulin E (IgE) antibodies with clinical symptoms to aeroallergens, such as those derived from house dust mites, pollens and pets. Since, in the economically-developed countries individuals spend most of their time indoors (home, school and workplace), indoor pollutants (tobacco smoke etc.) and allergens (house dust mite, cats, etc.) are the most important source of exposure. Indoor allergens are associated with a wide variety of particles in a broad size range, only some of which are microscopically identifiable, culturable, or detectable with existing immunoassay. Evaluation of indoor allergens requires both air and source sampling, and several different analytical techniques. It is likely that the increased prevalence of allergy and asthma may be caused in the indoor environment by the synergistic action of air pollution (in particular derived from tobacco smoking) with allergic sensitization. Passive smoking in infancy has also been involved in the airways allergic sensitization to common aeroallergens.

  15. Health effects from indoor air pollution: case studies.

    Science.gov (United States)

    White, L E; Clarkson, J R; Chang, S N

    1987-01-01

    In recent years there has been a growing awareness of the health effects associated with the presence of contaminants in indoor air. Numerous agents can accumulate in public buildings, homes and automobiles as a result of ongoing activities that normally occur in these closed spaces. Ventilation is a major factor in the control of indoor air pollutants since proper movement of air can prevent or minimize the build up of compounds in buildings. The recent emphasis on energy conservation has lead to measures which economize on energy for heating and air conditioning, but which also trap pollutants within a building. Three cases of indoor air pollution were investigated. A typical investigation of indoor air pollutant problems includes the following: interviews with building occupants; history of the building with regard to maintenance, pesticide treatment, etc.; a survey of the building and ventilation; and when warranted, sampling and analysis of air. Each case presented is unique in that atypical situations caused agents to accumulate in a building or section of a building. The indoor air problems in these cases were solved by identifying and removing the source of the offending agent and/or improving the ventilation in the building.

  16. Indoor radon distribution in metropolitan region of Belo Horizonte, Brazil

    International Nuclear Information System (INIS)

    Santos, Talita O.; Oliveira, Arno H. de

    2009-01-01

    Human beings are exposed to ionizing radiation from many natural sources. Radon and its progeny have been recognized as the most important contributors to the natural radioactivity dose, accounting for about half of all human exposure to ionizing radiation. Radon ( 222 Rn) is a α-radioactive noble gas derived from the natural series of uranium (2 38 U), which occurs in a wide concentration range in all geological materials, especially, in rocks, soils and waters. By diffusion and convection, radon migrates from the rocks and soils to atmosphere and through fissures, pipes and holes it may enter the dwellings and other buildings. Another important radon source in dwellings is its emanation from the construction material. The radon progeny concentration in dwellings has been receiving considerable global attention due to its potential effect in causing lung cancer if it deposited in upper respiratory tract when inhaled. This paper presents radon concentration distribution in dwellings in Metropolitan Region of Belo Horizonte - RMBH. The effective dose estimate is also presented for the RMBH inhabitants. The geological settings of the area are Archean rocks of Granitic Gnaissic Complex and of metasediments sequences of the great Precambrian unit of the Iron Quadrangle of Minas Gerais, Brazil. Radon concentration measurements were carried out with continuous detector AlphaGUARD PQ200PRO (Genitron), in passive mode and with passive detectors E-PERM R Eletret Ion Chamber-EIC. The radon progeny concentration was carried out with a solid state alpha spectroscope, the DOSEman PRO (Sarad). It was found an indoor radon concentration varying in a large range from 18.5 to 2671.4 Bq/m -3 , with an average value of 148.0 Bqm -3 and geometric mean equal to 128.2 Bqm -3 . The variable results are due mainly to region geological factors and building material composition of dwellings. The equilibrium factor between radon and its progeny were determined in dwellings, as 0.3 in

  17. Indoor environment and pupils' health in primary schools

    DEFF Research Database (Denmark)

    van Dijken, F.; van Bronswijk, J.E.M.H.; Sundell, Jan

    2006-01-01

    the associations between indoor environmental quality in Dutch schools and pupils' health, also taking into account the children's home environment and personal factors. A cross-sectional study was performed in 11 classrooms in 11 different schools in the Netherlands. The study included exposure measurements......Dutch children are legally bound to spend 15% of their time in a school setting. The indoor environment in Dutch primary schools is known to be substandard. However, it is unclear to what extent the health of pupils is affected by the indoor school environment. The paper aims to assess......, building inspections, and a questionnaire survey on pupils' health and domestic exposure. Principal Component Analysis (PCA) and non-parametric tests were performed to assess relationships. None of the schools complied with all indoor environmental quality standards. The importance of both the school...

  18. Indoor Air Pollution in Non Ac Passenger Bus

    Science.gov (United States)

    El Husna, Iksiroh; Unzilatirrizqi, Rizal D. Yan El; Karyanto, Yudi; Sunoko, Henna R.

    2018-02-01

    Passenger buses have been one of favorite means of transportation in Indonesia due to its affordability and flexibility. Intensity of human activities during the trip in the buses have a potential of causing indoor air pollution (polusi udara dalam ruang; PUDR). The indoor air pollution has an impact of 1000-time bigger than outdoor air pollution (polusi udara luar ruang; PULR) on lung. This study aimed to find out indoor air pollution rate of non air conditioned buses using an approach to biological agent pollutant source. The study applied an analysis restricted to microorganisms persistence as one of the sources of the indoor air pollution. The media were placed in different parts of the non AC buses. This study revealed that fungs were found in the non AC buses. They became contaminants and developed pathogenic bacteria that caused air pollution.

  19. Effects of Indoor Air Pollution on Human Health

    DEFF Research Database (Denmark)

    Berglund, B.; Brunekreef, B.; Knöppel, H.

    1992-01-01

    This article contains a summary discussion of human health effects linked to indoor air pollution (UP) in homes and other non-industrial environments. Rather than discussing the health effects of the many different pollutants which can be found in indoor air, the approach has been to group broad...... these are respiratory disease (particularly among children), allergy (particularly to house dust mites) and mucous membrane irritation (particularly due to formaldehyde). Large numbers of people have been, and are still being affected. Many chemicals encountered in indoor air are known or suspected to cause sensory...... irritation or stimulation. These, in turn, may give rise to a sense of discomfort and other symptums cummonly reported in so-called “sick” buildings. Camplex mixtures of organic chemicals in indoor air also have the potential to invoke subtle effects on the central and peripheral nervous system, leading...

  20. Design Criteria for Achieving Low Radon Concentration Indoors

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2016-01-01

    Design criteria for achieving low radon concentration indoors are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization in most...... countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. Three criteria when used can prevent radon infiltration and lower...... the radon concentration in the indoor air. In addition, a cheap and reliable method for measuring the radon concentration in the air indoors is described. The provision on radon in the Danish Building Regulations complies with the latest recommendations from the World Health Organization. Radon can cause...

  1. Indoor Air Pollution in Non Ac Passenger Bus

    Directory of Open Access Journals (Sweden)

    El Husna Iksiroh

    2018-01-01

    Full Text Available Passenger buses have been one of favorite means of transportation in Indonesia due to its affordability and flexibility. Intensity of human activities during the trip in the buses have a potential of causing indoor air pollution (polusi udara dalam ruang; PUDR. The indoor air pollution has an impact of 1000-time bigger than outdoor air pollution (polusi udara luar ruang; PULR on lung. This study aimed to find out indoor air pollution rate of non air conditioned buses using an approach to biological agent pollutant source. The study applied an analysis restricted to microorganisms persistence as one of the sources of the indoor air pollution. The media were placed in different parts of the non AC buses. This study revealed that fungs were found in the non AC buses. They became contaminants and developed pathogenic bacteria that caused air pollution.

  2. Indoor air 1. Recent advances in the health science and technology

    Energy Technology Data Exchange (ETDEWEB)

    Berglund, B; Lindvall, T; Sundell, J [eds.

    1984-01-01

    Health problems and discomfort caused by a bed indoor environment is discussed. The key note adresses in the first part of this volume covers the following subjects: Future buildings and building hygiene; Sick building syndrome; Lung cancer from radon and passive smoking; Total exposure estimation; Health implications of indoor air humidity; Indoor odors; Indoor allergies; Effect of moderate thermal stress and education of thermal discomfort; Airborne infections and modern building technology, Free radicals and oxidizing agents in the indoor air; Air quality control strategies, Achievement of the superclean environment. The seecond part of this publication contains works on policy and regulatory issues.

  3. Impact of indoor surface material on perceived air quality.

    Science.gov (United States)

    Senitkova, I

    2014-03-01

    The material combination impact on perceived indoor air quality for various surface interior materials is presented in this paper. The chemical analysis and sensory assessments identifies health adverse of indoor air pollutants (TVOCs). In this study, emissions and odors from different common indoor surface materials were investigated in glass test chamber under standardized conditions. Chemical measurements (TVOC concentration) and sensory assessments (odor intensity, air acceptability) were done after building materials exposure to standardized conditions. The results of the chemical and sensory assessment of individual materials and their combinations are compared and discussed within the paper. The using possibility of individual material surface sorption ability was investigated. The knowledge of targeted sorption effects can be used in the interior design phase. The results demonstrate the various sorption abilities of various indoor materials as well as the various sorption abilities of the same indoor material in various combinations. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Preventing skin cancer through reduction of indoor tanning: current evidence.

    Science.gov (United States)

    Watson, Meg; Holman, Dawn M; Fox, Kathleen A; Guy, Gery P; Seidenberg, Andrew B; Sampson, Blake P; Sinclair, Craig; Lazovich, DeAnn

    2013-06-01

    Exposure to ultraviolet radiation from indoor tanning devices (tanning beds, booths, and sun lamps) or from the sun contributes to the risk of skin cancer, including melanoma, which is the type of skin cancer responsible for most deaths. Indoor tanning is common among certain groups, especially among older adolescents and young adults, adolescent girls and young women, and non-Hispanic whites. Increased understanding of the health risks associated with indoor tanning has led to many efforts to reduce use. Most environmental and systems efforts in the U.S. (e.g., age limits or requiring parental consent/accompaniment) have occurred at the state level. At the national level, the U.S. Food and Drug Administration and the Federal Trade Commission regulate indoor tanning devices and advertising, respectively. The current paper provides a brief review of (1) the evidence on indoor tanning as a risk factor for skin cancer; (2) factors that may influence use of indoor tanning devices at the population level; and (3) various environmental and systems options available for consideration when developing strategies to reduce indoor tanning. This information provides the context and background for the companion paper in this issue of the American Journal of Preventive Medicine, which summarizes highlights from an informal expert meeting convened by the CDC in August 2012 to identify opportunities to prevent skin cancer by reducing use of indoor tanning devices. Published by Elsevier Inc.

  5. Indoor Air Quality: A Guide for Educators.

    Science.gov (United States)

    California State Dept. of Education, Sacramento.

    Indoor air quality is a major concern for educators involved in the development of new school facilities, or the remodeling and maintenance of existing ones. This guide addresses the issue of air quality, the health concerns involved, and procedures for minimizing the impact of pollutants in the school environment. It defines common indoor air…

  6. Indoor air quality environmental information handbook: Building system characteristics

    International Nuclear Information System (INIS)

    1987-01-01

    This manual, the third in a series, focuses on residential building system characteristics and their effects on indoor air quality. The manual addresses: residential indoor air pollutants by source, indoor concentrations, health effects, source control and mitigation techniques, standards and guidelines; building system characteristics of air exchange, pollutant source strength, residence volume, site characteristics, structural design, construction, and operation, infiltration and ventilation system, building occupancy; and monitoring methods

  7. Iron and stony-iron meteorites

    DEFF Research Database (Denmark)

    Benedix, Gretchen K.; Haack, Henning; McCoy, T. J.

    2014-01-01

    Without iron and stony-iron meteorites, our chances of ever sampling the deep interior of a differentiated planetary object would be next to nil. Although we live on a planet with a very substantial core, we will never be able to sample it. Fortunately, asteroid collisions provide us with a rich...... sampling of the deep interiors of differentiated asteroids. Iron and stony-iron meteorites are fragments of a large number of asteroids that underwent significant geological processing in the early solar system. Parent bodies of iron and some stony-iron meteorites completed a geological evolution similar...... to that continuing on Earth – although on much smaller length- and timescales – with melting of the metal and silicates; differentiation into core, mantle, and crust; and probably extensive volcanism. Iron and stony-iron meteorites are our only available analogues to materials found in the deep interiors of Earth...

  8. Investigation of infiltration and indoor air quality

    International Nuclear Information System (INIS)

    1990-03-01

    A multitask study was performed in the State of New York to provide information for guiding home energy conservation programs while maintaining acceptable indoor air quality. During the study, the statistical distribution of radon concentrations inside 2,400 homes was determined. The relationships among radon levels, house characteristics, and sources were also investigated. The direct impact that two specific air infiltration reduction measures--caulking and weatherstripping of windows and doors, and installation of storm windows and storm doors--have on house air leakage was investigated in 60 homes. The effect of house age on the impact of weatherization was also evaluated. Indoor and outdoor measurements of NO 2 , CO, SO 2 , and respirable suspended particulates (RSP) were made for 400 homes to determine the effect of combustion sources on indoor air quality and to characterize the statistical distribution of the concentrations. Finally, the combustion source data were combined with the information on air infiltration reduction measures to estimate the potential impact of these measures on indoor air quality

  9. Indoor air. Seminar of Zentrale Informationsstelle, Umweltberatung Bayern. Vol. 2

    International Nuclear Information System (INIS)

    Koller, U.; Haury, H.J.

    1994-02-01

    This seminar dealt with the subject of indoor air pollution and welcomed participants from environmental consultancy agencies and authorities and institutions related with environmental protection. Leading scientists from research and authorities presented the current state of knowledge abut the risks of indoorair pollution. The papers contained in these proceedings addressed: room climate and sick-building syndrome; allergens in indoor spaces; pollutants emitted by exemplary building materials; pollutant levels of organic compounds in indoor spaces; air quality in motor vehicle interiors; indoor air pollution - risk assessment and need for actions. (Uhe) [de

  10. A proposed UAV for indoor patient care.

    Science.gov (United States)

    Todd, Catherine; Watfa, Mohamed; El Mouden, Yassine; Sahir, Sana; Ali, Afrah; Niavarani, Ali; Lutfi, Aoun; Copiaco, Abigail; Agarwal, Vaibhavi; Afsari, Kiyan; Johnathon, Chris; Okafor, Onyeka; Ayad, Marina

    2015-09-10

    Indoor flight, obstacle avoidance and client-server communication of an Unmanned Aerial Vehicle (UAV) raises several unique research challenges. This paper examines current methods and associated technologies adapted within the literature toward autonomous UAV flight, for consideration in a proposed system for indoor healthcare administration with a quadcopter. We introduce Healthbuddy, a unique research initiative towards overcoming challenges associated with indoor navigation, collision detection and avoidance, stability, wireless drone-server communications and automated decision support for patient care in a GPS-denied environment. To address the identified research deficits, a drone-based solution is presented. The solution is preliminary as we develop and refine the suggested algorithms and hardware system to achieve the research objectives.

  11. Design and Development of a Nearable Wireless System to Control Indoor Air Quality and Indoor Lighting Quality

    Directory of Open Access Journals (Sweden)

    Francesco Salamone

    2017-05-01

    Full Text Available The article describes the results of the project “open source smart lamp” aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ of the built environment. A first version of this smart object, built following a do-it-yourself (DIY approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ, by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ, indoor lighting quality (ILQ and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ.

  12. Seasonal and Spatial Variations of Indoor Pollen in a Hospital

    Directory of Open Access Journals (Sweden)

    Santiago Fernández-Rodríguez

    2009-12-01

    Full Text Available The airborne indoor pollen in a hospital of Badajoz (Spain was monitored over two years using a personal Burkard sampler. The air was sampled in four places indoors—one closed room and one open ward on each of the ground and the third floors—and one place outdoors at the entrance to the hospital. The results were compared with data from a continuous volumetric sampler. While 32 pollen types were identified, nearly 75% of the total counts were represented by just five of them. These were: Quercus, Cupressaceae, Poaceae, Olea, and Plantago. The average indoor concentration was 25.2 grains/m3, and the average indoor/outdoor ratio was 0.27. A strong seasonal pattern was found, with the highest levels in spring and winter, and the indoor concentrations were correlated with the outdoor one. Indoor air movement led to great homogeneity in the airborne pollen presence: the indoor results were not influenced by whether or not the room was isolated, the floor level, or the number of people in or transiting the site during sampling. The presence of ornamental vegetation in the area surrounding the building affected the indoor counts directly as sources of the pollen.

  13. Controlled atmosphere for fabrication of cermet electrodes

    Science.gov (United States)

    Ray, Siba P.; Woods, Robert W.

    1998-01-01

    A process for making an inert electrode composite wherein a metal oxide and a metal are reacted in a gaseous atmosphere at an elevated temperature of at least about 750.degree. C. The metal oxide is at least one of the nickel, iron, tin, zinc and zirconium oxides and the metal is copper, silver, a mixture of copper and silver or a copper-silver alloy. The gaseous atmosphere has an oxygen content that is controlled at about 5-3000 ppm in order to obtain a desired composition in the resulting composite.

  14. Iron oxide nanotubes synthesized via template-based electrodeposition

    Science.gov (United States)

    Lim, Jin-Hee; Min, Seong-Gi; Malkinski, Leszek; Wiley, John B.

    2014-04-01

    Considerable effort has been invested in the development of synthetic methods for the preparation iron oxide nanostructures for applications in nanotechnology. While a variety of structures have been reported, only a few studies have focused on iron oxide nanotubes. Here, we present details on the synthesis and characterization of iron oxide nanotubes along with a proposed mechanism for FeOOH tube formation. The FeOOH nanotubes, fabricated via a template-based electrodeposition method, are found to exhibit a unique inner-surface. Heat treatment of these tubes under oxidizing or reducing atmospheres can produce either hematite (α-Fe2O3) or magnetite (Fe3O4) structures, respectively. Hematite nanotubes are composed of small nanoparticles less than 20 nm in diameter and the magnetization curves and FC-ZFC curves show superparamagnetic properties without the Morin transition. In the case of magnetite nanotubes, which consist of slightly larger nanoparticles, magnetization curves show ferromagnetism with weak coercivity at room temperature, while FC-ZFC curves exhibit the Verwey transition at 125 K.Considerable effort has been invested in the development of synthetic methods for the preparation iron oxide nanostructures for applications in nanotechnology. While a variety of structures have been reported, only a few studies have focused on iron oxide nanotubes. Here, we present details on the synthesis and characterization of iron oxide nanotubes along with a proposed mechanism for FeOOH tube formation. The FeOOH nanotubes, fabricated via a template-based electrodeposition method, are found to exhibit a unique inner-surface. Heat treatment of these tubes under oxidizing or reducing atmospheres can produce either hematite (α-Fe2O3) or magnetite (Fe3O4) structures, respectively. Hematite nanotubes are composed of small nanoparticles less than 20 nm in diameter and the magnetization curves and FC-ZFC curves show superparamagnetic properties without the Morin transition

  15. Core public health functions for BC : evidence review : air quality-indoor

    Energy Technology Data Exchange (ETDEWEB)

    Copes, R.; Ouellette, V.; Lee, K.S.; Brauer, M. [British Columbia Ministry of Health, Victoria, BC (Canada)

    2006-04-15

    Indoor sources of pollutants can have a major impact on the health of Canadians, as pollutant concentrations are often higher indoors than outdoors. This paper assessed data compiled by public health indoor air interventions. The aim of the study was to identify the current state of evidence on the impacts of indoor pollution in order to develop performance improvement plans for public health programs in British Columbia (BC). The literature review used several databases to review interventions involving humidity control; ventilation; particulate matter; indoor allergens; and environmental tobacco smoke. Results of the review showed that improving inadequate ventilation can significantly decrease the prevalence of sick building syndrome as well as other self-reported symptoms attributed to indoor air pollution. A review of the literature also demonstrated that many building ventilation systems are not functioning to design specifications. The poor quality of studies on the health impacts of particulate matter or dust made it difficult to fully assess the benefits of particle filtration on human health. Studies investigating the impacts of controlling indoor allergens suggested that the avoidance of dust mites may benefit people with allergies. Evidence gained from studies on environmental tobacco smoke showed that banning or restricting smoking will reduce the burden of illness from pollutants in indoor air. 20 refs., 3 tabs.

  16. Core public health functions for BC : evidence review : air quality-indoor

    International Nuclear Information System (INIS)

    Copes, R.; Ouellette, V.; Lee, K.S.; Brauer, M.

    2006-04-01

    Indoor sources of pollutants can have a major impact on the health of Canadians, as pollutant concentrations are often higher indoors than outdoors. This paper assessed data compiled by public health indoor air interventions. The aim of the study was to identify the current state of evidence on the impacts of indoor pollution in order to develop performance improvement plans for public health programs in British Columbia (BC). The literature review used several databases to review interventions involving humidity control; ventilation; particulate matter; indoor allergens; and environmental tobacco smoke. Results of the review showed that improving inadequate ventilation can significantly decrease the prevalence of sick building syndrome as well as other self-reported symptoms attributed to indoor air pollution. A review of the literature also demonstrated that many building ventilation systems are not functioning to design specifications. The poor quality of studies on the health impacts of particulate matter or dust made it difficult to fully assess the benefits of particle filtration on human health. Studies investigating the impacts of controlling indoor allergens suggested that the avoidance of dust mites may benefit people with allergies. Evidence gained from studies on environmental tobacco smoke showed that banning or restricting smoking will reduce the burden of illness from pollutants in indoor air. 20 refs., 3 tabs

  17. Reply to "Can the levels of Can f 1 in indoor environments be evaluated without considering passive transport of allergen indoors?"

    NARCIS (Netherlands)

    Krop, E.J.M.; Vredegoor, D.W.; Chapman, M.D.; Willemse, A.; Heederik, D.J.J.

    2013-01-01

    Response to Liccardi G, Salzillo A, Piccolo A, D’Amato M, D’Amato G. Can the levels of Can f 1 in indoor environments be evaluated without considering passive transport of allergen indoors? J Allergy Clin Immunol 2013;131:1258-9.

  18. Effect of home construction on indoor radon in Virginia and Maryland

    International Nuclear Information System (INIS)

    Mushrush, G.W.; Mose, D.G.

    1988-01-01

    The levels of indoor radon in approximately 500 homes located in two contiguous counties of northern Virginia and southern Maryland have been measured during four consecutive, three month seasonal intervals using alpha-track detectors. These two counties represent an area of about 700 square miles. Results from the winter period show that the indoor radon levels were about twice as high as anticipated. In some areas, more than 50% of the homes had winter indoor radon levels above 4 pCi/liter, the EPA's recommended action level. For the spring and fall periods, indoor radon levels showed a considerable drop with approximately 35% of the homes above 4 pCi/L. Summer values were even lower with approximately 25% of the homes above 4 pCi/L.Indoor radon can be related to the weather, but home construction demonstrably determines indoor radon levels

  19. Perceptions of indoor vs. outdoor tanning risks among melanoma patients who have a history of indoor UV tanning: an international internet survey

    OpenAIRE

    Nergard, Jennifer; Caldwell, Chauncey; Barr, Morgan; Dellavalle, Robert P; Solomon, James A

    2016-01-01

    IntroductionA new U.S. FDA regulation categorizes tanning beds as category II¹, and similar global regulatory action require informing users of the “risk of skin cancer” as methods to reverse the growing trend of indoor tanning. However, little is known from the patient’s perspective on whether or not knowledge of risk of cancer is a deterrent to indoor tanning. Also, there is conflicting literature on the relationship between frequency of indoor tanning, age of onset and characteristics of p...

  20. Indoor Positioning with Smartphones:The State-of-the-art and the Challenges

    Directory of Open Access Journals (Sweden)

    CHEN Ruizhi

    2017-10-01

    Full Text Available Indoor positioning is one of the core technologies of artificial intelligence (AI in the future and will play a pivotal role in the upcoming era of AI. Currently, indoor positioning is one of the hot research topics in academic and industrial society. Google, as one of the leading information technology (IT companies, has listed visual positioning service (VPS as one of the core technologies. Apple has endeavored to prompt iBeacon, the low energy Bluetooth technology for indoor positioning. In cooperation with a Finnish company, IndoorAltas, Baidu launched an indoor positioning program with a magnetic matching approach. All these initiatives and new technologies have shown the significance and necessaries of indoor positioning. However, affected by the complexity of the indoor spaces, it is still challenging to achieve accurate, effective, full coverage and real-time positioning solution indoors. With the popularity of smart phones and the rapid development of MEMS sensors in recent years, many methods have been proposed to use the smartphone built-in sensors and RF radios for indoor positioning. In this paper, we focus on indoor positioning technologies for smartphones and classify the different technologies into two categories, namely the radio frequency (RF technologies and the sensors technologies. The state-of-the-art of the technologies has been reviewed. The pros and cons of the technologies have been commented in the context of different application scenarios. Moreover, the challenges of indoor positioning have also been pointed out and the directions of the future development of this area have been discussed.

  1. Education versus regulation: The case for regulating the indoor tanning industry.

    Science.gov (United States)

    Benet, Suzeanne; Kraft, Frederic

    2016-05-01

    We examine marketing strategies for indoor tanning services that often target young adult females. Evidence of the addictive nature of indoor tanning suggests that young adults may be vulnerable to the promotion of indoor tanning and as a result deserve greater protection from the marketing of these services. As public awareness of the rising numbers of skin cancers linked to indoor tanning grows, we believe that the public will support increased regulation of this industry.

  2. Indoor Climate and Air Quality Problems

    DEFF Research Database (Denmark)

    Valbjørn, O.; Hagen, H.; Kukkonen, E.

    This report presents a stepwise method for the investigation of and remedial actions for indoor climate and air quality problems. The report gives the basis for evaluation of the prevalence and causes of building related symptoms like mucosal irritation and headache. The report adresses members...... of occupational health and safety organisations, consulting engineers and architects, and also the people responsible for the operation of buildings and installations which is essential for the indoor climate and air quality....

  3. Indoor unit for electric heat pump

    Science.gov (United States)

    Draper, R.; Lackey, R.S.; Fagan, T.J. Jr.; Veyo, S.E.; Humphrey, J.R.

    1984-05-22

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module, an air mover module, and a resistance heat package module, the refrigeration module including all of the indoor refrigerant circuit components including the compressor in a space adjacent the heat exchanger, the modules being adapted to be connected to air flow communication in several different ways as shown to accommodate placement of the unit in various orientations. 9 figs.

  4. Indoor radon pollution: update. Bibliographic series

    International Nuclear Information System (INIS)

    Richard, S.A.

    1988-12-01

    This bibliography focuses on indoor radon pollution problems and is organized according to the following major topic areas: I-Overview (covering general areas such as law and policy, popular press, communication and education, indoor air and books); II-Health Effects (epidemiology, risk estimates, and dosimetry); III-Exposure (house construction, geology, source, physical properties, and radon in water); IV-Surveys (national and international case studies); V-Mitigation; and VI-Measurement Techniques. Section VIII-Appendix, lists State Contacts

  5. Indoor Tanning Among High School Students in the United States, 2009 and 2011

    Science.gov (United States)

    Guy, Gery P.; Berkowitz, Zahava; Tai, Eric; Holman, Dawn M.; Jones, Sherry Everett; Richardson, Lisa C.

    2015-01-01

    IMPORTANCE Indoor tanning is associated with an increased risk of skin cancer, including melanoma, and is particularly dangerous for younger and more frequent indoor tanners. OBJECTIVE To examine the prevalence of indoor tanning and frequent indoor tanning (≥10 times during the 12 months before each survey) and their association with health-related behaviors. DESIGN, SETTING, AND PARTICIPANTS A cross-sectional study examined data from the 2009 and 2011 national Youth Risk Behavior Surveys, which used nationally representative samples of US high school students representing approximately 15.5 million students each survey year. The study included 25 861 students who answered the indoor tanning question. MAIN OUTCOMES AND MEASURES The prevalence of indoor tanning and frequent indoor tanning were examined as well as their association with demographic characteristics and health-related behaviors using multivariable logistic regression modeling. RESULTS The prevalence of indoor tanning was greater among female, older, and non-Hispanic white students. Indoor tanning was highest among female students aged 18 years or older, with 31.5% engaging in indoor tanning in 2011, and among non-Hispanic white female students, with 29.3% engaging in indoor tanning in 2011. Among female students, the adjusted prevalence of indoor tanning decreased from 26.4% in 2009 to 20.7% in 2011. Among female and male students, indoor tanning was associated with other risk-taking behaviors, such as binge drinking (P < .001 and P = .006, respectively), unhealthy weight control practices (P < .001, for both), and having sexual intercourse (P < .001, for both). Additionally, indoor tanning among female students was associated with using illegal drugs (P < .001) and having sexual intercourse with 4 or more persons (P = .03); use among male students was associated with taking steroids without a physician’s prescription (P < .001), smoking cigarettes daily (P = .03), and attempting suicide (P = .006

  6. High indoor radon concentrations in some Swedish waterworks

    International Nuclear Information System (INIS)

    Aakerblom, G.; Hagberg, N.; Mjoenes, L.; Heiberg, A.

    2002-01-01

    High indoor radon concentrations in buildings used for water treatment are not uncommon. When raw water is processed in an open system radon escapes from the water to the indoor air of the premises. It is not unusual that the staff of the waterworks have their offices in the building where the water is processed. If large volumes of water are processed and the evaporated radon can reach the workplaces the indoor radon concentration can be very high even if the radon concentration of the raw water is moderate. Groundwaters from aquifers in bedrock and soil and surface water that has been infiltrated through deposits of sand or gravel have the potential to cause high indoor radon levels. In surface water emanating directly from a lake or a river the radon concentrations are normally too low to cause problems. Three waterworks in central Sweden have been studied, Ludvika, Fredriksberg and Kolbaeck. The radon concentrations in the raw water of these waterworks are from 85 Bq/l to 300 Bq/l. Average indoor radon concentrations exceeding 17,000 Bq/m 3 have been measured in Ludvika with peaks of almost 37,000 Bq/m 3 . In Kolbaeck radon concentrations up to 56,000 Bq/m 3 have been measured. It is quite possible that employees of waterworks can receive doses exceeding 20 mSv per year (calculated according to ICRP:s dose conversion convention). Measurements of radon and gamma radiation from the waterworks are reported and methods to lower the indoor radon concentrations are discussed. (author)

  7. Exposure to indoor tanning without burning and melanoma risk by sunburn history.

    Science.gov (United States)

    Vogel, Rachel Isaksson; Ahmed, Rehana L; Nelson, Heather H; Berwick, Marianne; Weinstock, Martin A; Lazovich, DeAnn

    2014-06-01

    Indoor tanning is carcinogenic to humans. Individuals report that they tan indoors before planning to be in the sun to prevent sunburns, but whether skin cancer is subsequently reduced is unknown. Using a population-based case-control study, we calculated the association between melanoma and indoor tanning after excluding exposed participants reporting indoor tanning-related burns, stratified by their number of lifetime sunburns (0, 1-2, 3-5, >5). Confounding was addressed using propensity score analysis methods. All statistical tests were two-sided. We observed increased risk of melanoma across all sunburn categories for participants who had tanned indoors without burning compared with those who never tanned indoors, including those who reported zero lifetime sunburns (odds ratio = 3.87; 95% confidence interval = 1.68 to 8.91; P = .002). These data provide evidence that indoor tanning is a risk factor for melanoma even among persons who reported never experiencing burns from indoor tanning or outdoor sun exposure. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  8. Indoor environmental quality in Hellenic hospital operating rooms

    Energy Technology Data Exchange (ETDEWEB)

    Dascalaki, Elena G.; Gaglia, Athina G.; Balaras, Constantinos A. [Group Energy Conservation, Institute for Environmental Research and Sustainable Development, National Observatory of Athens, I. Metaxa and Vas. Pavlou, GR 152 36 P. Penteli (Greece); Lagoudi, Argyro [Terra Nova Ltd., Environmental Engineering Consultancy, Athens, Kaisareias 39, GR 115 27 Athens (Greece)

    2009-05-15

    Indoor environmental quality (IEQ) in hospital operating rooms (ORs) constitutes a major challenge for the proper design and operation of an energy efficient hospital. A subjective assessment of the indoor environment along with a short monitoring campaign was performed during the audits of 18 ORs at nine major Hellenic hospitals. A total of 557 medical personnel participated in an occupational survey, providing data for a subjective assessment of IEQ in the audited ORs. The OR personnel reported work related health symptoms and an assessment of indoor conditions (thermal, visual and acoustical comfort, and air quality). Overall, personnel reported an average of 2.24 work-related symptoms each, and 67.2% of respondents reported at least one. Women suffer more health symptoms than men. Special dispositions, such as smoking and allergies, increase the number of reported symptoms for male and female personnel. Personnel that perceive satisfactory indoor comfort conditions (temperature, humidity, ventilation, light, and noise) average 1.18 symptoms per person, while for satisfactory indoor air quality the average complaints are 0.99. The perception of satisfactory IEQ (satisfactory comfort conditions and air quality) reduces the average number of health complaints to 0.64 symptoms per person and improves working conditions, even in a demanding OR environment. (author)

  9. An investigation of factors influencing indoor radon concentrations

    International Nuclear Information System (INIS)

    Majborn, B.; Soerensen, A.; Nielsen, S.P.; Boetter-Jensen, L.

    1988-05-01

    Variations in indoor radon concentrations and some influencing factors have been studied during a two-year period (1986-1987) in 16 almost identical single-family houses.The annual average radon concentration in the houses varied from about 50 to about 400 Bq/m 3 . Variations in soil characteristics and radon concentration in soil gas could not be directly related to the variations of the average indoor radon concentrations. Most of the houses showed a ''normal'' seasonal variation of the radon concentration with a maximum in the winter and minimum in the summer. A deviating seasonal variation was found in three of the houses. Hourly data obtained in one unoccupied house during a period of 2-1/2 months showed no or only weak correlations between the indoor radon concentration and meteorological factors. However, for most of the houses, the seasonal variation of the indoor radon concentration was well correlated with the average indoor-outdoor temperature difference on a 2-month basis. It was demonstrated that the radon concentration can be strongly reduced in the Risoe houses if a district-heating duct, which is connected to all the houses, is ventilated, so that a slightly lowered pressure is maintained in the duct. 5 taps., 24 ill. (author)

  10. Spatial models for context-aware indoor navigation systems: A survey

    Directory of Open Access Journals (Sweden)

    Imad Afyouni

    2012-06-01

    Full Text Available This paper surveys indoor spatial models developed for research fields ranging from mobile robot mapping, to indoor location-based services (LBS, and most recently to context-aware navigation services applied to indoor environments. Over the past few years, several studies have evaluated the potential of spatial models for robot navigation and ubiquitous computing. In this paper we take a slightly different perspective, considering not only the underlying properties of those spatial models, but also to which degree the notion of context can be taken into account when delivering services in indoor environments. Some preliminary recommendations for the development of indoor spatial models are introduced from a context-aware perspective. A taxonomy of models is then presented and assessed with the aim of providing a flexible spatial data model for navigation purposes, and by taking into account the context dimensions.

  11. Indoor Air Quality Building Education and Assessment Model Forms

    Science.gov (United States)

    The Indoor Air Quality Building Education and Assessment Model (I-BEAM) is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.

  12. Indoor Location Technologies

    CERN Document Server

    Goswami, Subrata

    2013-01-01

    Focusing on the special challenges posed by accurately pinpointing a location indoors, this volume reflects the distance we have come in the handful of decades since the germination of GPS technology. Not only can we locate a signal to within a meter’s accuracy, but we now have this technology in the most basic mobile phone. Tracing recent practical developments in positioning technology and in the market it supplies, the author examines the contributions of the varied research—in silicon, signal and image processing, radio communications and software—to a fast-evolving field. The book looks forward to a time when, in addition to directing your road journey, positioning systems can peer indoors and guide you to an available photocopier in your office building. Featuring standalone chapters each dealing with a specific aspect of the subject, including treatments of systems such as Zebra, Awarepoint, Aeroscout, IEEE 802.11, etc. This study has all the detail needed to get up to speed on a key modern techn...

  13. Method for Improving Indoor Positioning Accuracy Using Extended Kalman Filter

    Directory of Open Access Journals (Sweden)

    Seoung-Hyeon Lee

    2016-01-01

    Full Text Available Beacons using bluetooth low-energy (BLE technology have emerged as a new paradigm of indoor positioning service (IPS because of their advantages such as low power consumption, miniaturization, wide signal range, and low cost. However, the beacon performance is poor in terms of the indoor positioning accuracy because of noise, motion, and fading, all of which are characteristics of a bluetooth signal and depend on the installation location. Therefore, it is necessary to improve the accuracy of beacon-based indoor positioning technology by fusing it with existing indoor positioning technology, which uses Wi-Fi, ZigBee, and so forth. This study proposes a beacon-based indoor positioning method using an extended Kalman filter that recursively processes input data including noise. After defining the movement of a smartphone on a flat two-dimensional surface, it was assumed that the beacon signal is nonlinear. Then, the standard deviation and properties of the beacon signal were analyzed. According to the analysis results, an extended Kalman filter was designed and the accuracy of the smartphone’s indoor position was analyzed through simulations and tests. The proposed technique achieved good indoor positioning accuracy, with errors of 0.26 m and 0.28 m from the average x- and y-coordinates, respectively, based solely on the beacon signal.

  14. Sintering studies on iron-carbon-copper compacts

    Directory of Open Access Journals (Sweden)

    Perianayagam Philomen-D-Anand Raj

    2016-01-01

    Full Text Available Sintered Iron-Carbon-Copper parts are among the most widely used powder metallurgy product in automobile. In this paper, studies have been carried out to find out the sintering characteristics of iron-carbon-copper compacts when sintered in nitrogen atmosphere. The effects of various processing parameters on the sintering characteristics were studied. The various processing parameters considered were compaction pressure, green density and sintering temperature. The sintering characteristics determined were sintered density, porosity, dimensional change, micro hardness and radial crush strength. The results obtained have been discussed on the basis of micro structural observations. The characteristics of SEM fractography were also used to determine the mechanism of fracture. The fracture energy is strongly dependent on density of the compact.

  15. D Modelling of AN Indoor Space Using a Rotating Stereo Frame Camera System

    Science.gov (United States)

    Kang, J.; Lee, I.

    2016-06-01

    Sophisticated indoor design and growing development in urban architecture make indoor spaces more complex. And the indoor spaces are easily connected to public transportations such as subway and train stations. These phenomena allow to transfer outdoor activities to the indoor spaces. Constant development of technology has a significant impact on people knowledge about services such as location awareness services in the indoor spaces. Thus, it is required to develop the low-cost system to create the 3D model of the indoor spaces for services based on the indoor models. In this paper, we thus introduce the rotating stereo frame camera system that has two cameras and generate the indoor 3D model using the system. First, select a test site and acquired images eight times during one day with different positions and heights of the system. Measurements were complemented by object control points obtained from a total station. As the data were obtained from the different positions and heights of the system, it was possible to make various combinations of data and choose several suitable combinations for input data. Next, we generated the 3D model of the test site using commercial software with previously chosen input data. The last part of the processes will be to evaluate the accuracy of the generated indoor model from selected input data. In summary, this paper introduces the low-cost system to acquire indoor spatial data and generate the 3D model using images acquired by the system. Through this experiments, we ensure that the introduced system is suitable for generating indoor spatial information. The proposed low-cost system will be applied to indoor services based on the indoor spatial information.

  16. Feasible Indoor Air-related measures against Avian Influenza

    NARCIS (Netherlands)

    Franchimon, F.; Pernot, C.E.E.; Bronswijk, van J.E.M.H.; Olesen, BW; Wargocki, P; Strøm-Tejsen, P; Zukowska, D; Toftum, J

    2008-01-01

    The threat of a new pandemic has forced the WHO to publish preparedness plans. Although WHO recognized the effect of airborne transmission of the causative agent, they did not attempt to include feasible measures for indoor environmental control as yet. The efficacy of indoor humidity control

  17. Great Indoors Awards 2007

    Index Scriptorium Estoniae

    2007-01-01

    Hollandis Maastrichtis jagati 17. XI esimest korda rahvusvahelist auhinda The Great Indoors Award. Aasta sisekujundusfirmaks valiti Masamichi Katayama asutatud Wonderwall. Auhinna said veel Zaha Hadid, Heatherwick Studio, Ryui Nakamura Architects ja Item Idem

  18. Optimal training sequences for indoor wireless optical communications

    International Nuclear Information System (INIS)

    Wang, Jun-Bo; Jiao, Yuan; Song, Xiaoyu; Chen, Ming

    2012-01-01

    Since indoor wireless optical communication (WOC) systems can offer several potential advantages over their radio frequency counterparts, there has been a growing interest in indoor WOC systems. Influenced by the complicated optical propagation environment, there exist multipath propagation phenomena. In order to eliminate the effect of multipath propagation, much attention should be concentrated on the channel estimation in indoor WOC systems. This paper investigates optimal training sequences (TSs) for estimating a channel impulse response in indoor WOC systems. Based on the Cramer–Rao bound (CRB) theorem, an explicit form of search criterion is found. Optimum TSs are obtained and tabulated by computer search for different channel responses and TS lengths. Measured by mean square error (MSE) performance, channel estimation errors are also investigated. Simulation results show that the MSE of the channel estimator at the receiver can be reduced significantly by using the optimized TS set. Moreover, the longer the TS, the better the MSE performance that can be obtained when the channel order is fixed. (paper)

  19. Perceptions of tanning risk among melanoma patients with a history of indoor tanning.

    Science.gov (United States)

    Nergard-Martin, Jennifer; Caldwell, Chauncey; Barr, Morgan; Dellavalle, Robert P; Solomon, James A

    2018-01-01

    A new US Food and Drug Administration (FDA) regulation classified tanning beds as class II, requiring indoor tanning facilities to inform users of the risk of skin cancer in efforts to reverse the growing trend in indoor tanning. However, little is known from the patient's perspective on whether knowledge of the risk of skin cancer development is a deterrent to indoor tanning. There also is conflicting literature regarding the relationship among frequency of indoor tanning, age at onset of melanoma diagnosis, and characteristics of diagnosis in melanoma patients with a history of indoor tanning. An international survey was conducted in patients 18 years and older who self-reported being diagnosed with melanoma after indoor tanning. The purpose of this study was to investigate the patients' perspective on indoor-tanning behaviors as associated with the severity of their melanomas and the time frame in which they were diagnosed as well as their perceived views on the safety of indoor tanning and the frequency in which they continue to tan indoors.

  20. Indoor Air Quality

    DEFF Research Database (Denmark)

    Selman, Ayser Dawod; Heiselberg, Per

    Overall purpose of the research is to provide an overview of the relevance and importance of various defined Indoor Air Quality (IAQ) parameters in a European perspective. Based on the report it should be possible to prioritize which countries to target for further activities as well as it should...

  1. Research on Integration of Indoor and Outdoor Positioning in Professional Athletic Training

    Directory of Open Access Journals (Sweden)

    Yongqing Liu

    2018-02-01

    Full Text Available GNSS is widely used in professional athletic training as an outdoor location based services, and the indoor positioning technology has gradually flourished in the gymnasium. To keep up with the demand for athletic training in indoor and outdoor environment, integration of indoor and outdoor positioning technology can achieve a seamless indoor/outdoor position solution. The proposed method uses GPS/BEIDOU with IMU-MEMS technology for outdoor positioning and UWB with IMU-MEMS technology for indoor positioning to provide high precision positioning services. The experimental results show that the proposed method can achieve meter level position accuracy in outdoor environment and centimeter level position accuracy in indoor environment, it can provide precise and real-time positioning service for effective athletic training aid.

  2. Evaluating Wi-Fi indoor positioning approaches in a real world environment

    OpenAIRE

    Hantoush, Raafat

    2016-01-01

    Global positioning system(GPS) does not provide generally a good positioning performance in an indoor location because of many reasons (Henniges, 2012). On the other hand, other alternatives such as the WI-FI technology has become recently in a popular use to provide indoor localization. And that is due to many reasons, such as the wide spread of WI-FI infrastructure in the indoor environments and the low cost of this technology. This study attempts to evaluate different WI-FI indoor position...

  3. Defining indoor heat thresholds for health in the UK.

    Science.gov (United States)

    Anderson, Mindy; Carmichael, Catriona; Murray, Virginia; Dengel, Andy; Swainson, Michael

    2013-05-01

    It has been recognised that as outdoor ambient temperatures increase past a particular threshold, so do mortality/morbidity rates. However, similar thresholds for indoor temperatures have not yet been identified. Due to a warming climate, the non-sustainability of air conditioning as a solution, and the desire for more energy-efficient airtight homes, thresholds for indoor temperature should be defined as a public health issue. The aim of this paper is to outline the need for indoor heat thresholds and to establish if they can be identified. Our objectives include: describing how indoor temperature is measured; highlighting threshold measurements and indices; describing adaptation to heat; summary of the risk of susceptible groups to heat; reviewing the current evidence on the link between sleep, heat and health; exploring current heat and health warning systems and thresholds; exploring the built environment and the risk of overheating; and identifying the gaps in current knowledge and research. A global literature search of key databases was conducted using a pre-defined set of keywords to retrieve peer-reviewed and grey literature. The paper will apply the findings to the context of the UK. A summary of 96 articles, reports, government documents and textbooks were analysed and a gap analysis was conducted. Evidence on the effects of indoor heat on health implies that buildings are modifiers of the effect of climate on health outcomes. Personal exposure and place-based heat studies showed the most significant correlations between indoor heat and health outcomes. However, the data are sparse and inconclusive in terms of identifying evidence-based definitions for thresholds. Further research needs to be conducted in order to provide an evidence base for threshold determination. Indoor and outdoor heat are related but are different in terms of language and measurement. Future collaboration between the health and building sectors is needed to develop a common

  4. Improving Indoor Air Quality

    Science.gov (United States)

    Usually the most effective way to improve indoor air quality is to eliminate individual sources of pollution or to reduce their emissions. Some sources, like those that contain asbestos, can be sealed or enclosed.

  5. Modeling and evaluation tools for the indoor climate

    NARCIS (Netherlands)

    Schijndel, van A.W.M.

    2005-01-01

    The appendix contains the paper presented at the 26TthAIVC Conference Brussels, 21-23 September 2005. The paper provides a study of the indoor climate of a monumental building with periodic high indoor moisture loads. Several scenarios of the past performance and new control classes are simulated

  6. Indoor house pollution: appliance emissions and indoor ambient concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Caceres, T [Univ. of Santiago, Chile; Soto, H; Lissi, E; Cisternas, R

    1983-01-01

    Emissions rates for CO, NO, NO/sub 2/ adn CH/sub 2/O from several unvented gas and kerosene heaters frequently employed in domestic heating have been measured. The indoor concentrations generated by these emissions are evaluated and compared to those determined in typical houses. It is found that both the predicted and measured values exceed the short term air quality standards accepted in most countries.

  7. Impact of operating wood-burning stoves on indoor air quality

    DEFF Research Database (Denmark)

    Afshari, Alireza; Jensen, Ole Michael; Bergsøe, Niels Christian

    2011-01-01

    A field study on the impact of operating and reloading wood-burning stoves on the indoor air quality was carried out during two consecutive winters. In contrast to the majority of recent studies, which focussed on the ambient air quality and the penetration of particles to the indoor air......, this study aims to understand to what extent the operation of a stove contributes to the generation of concentration of ultrafine particles in the indoor air. Therefore, different stoves were ignited in one session by the owner of the stove and in a subsequent session by an expert on wood-burning stoves....... The study was conducted in seven typical Danish detached houses without other indoor activities taking place. In each house the average air change rate during one week was measured (using passive tracer gas technique) and the indoor and outdoor temperature and relative humidity were recorded continuously...

  8. Geologic controls on indoor radon in the Pacific Northwest

    International Nuclear Information System (INIS)

    Otton, J.K.; Duval, J.S.

    1990-01-01

    This paper reports on comparisons of average indoor radon levels, soil radium content (derived from aerial gamma-ray data), and soil characteristics for selected townships in Washington, Oregon, and Idaho which show that: soil radium content provides a first-order estimate of the relative amounts of indoor radon where soils are either of low to moderate intrinsic permeability or of permeability reduced by high moisture; in drier parts of the study area (east of the Cascade Mountains), unusually high average indoor radon levels are almost all characterized by soils that have high effective permeabilities (greater than 20 inches per hour), based on available country soil descriptions; and in the wetter parts of the study area (west of the Cascade Mountains), townships with unusually high indoor radon levels are characterized by steeply sloped soils

  9. Effect of fresh air ventilation on indoor radon concentration

    International Nuclear Information System (INIS)

    Sun Hao; Wu Jianhua; Fu Shi

    2012-01-01

    The radon concentration of laboratory for radon simulation (LRS) was measured by the RAD7 radon monitor, and the effect of the different fresh air ventilations on indoor radon concentration was studied and analyzed. The indoor radon concentration of LRS can be accumulated up to 2000 Bq/m 3 and the average radon exhalation rate of the LRS is 14.5 Bq · m -2 . h -1 . Furthermore, when the fresh air enters into the LRS continuously, the indoor radon concentration decreases exponentially with the increase of time. The equilibrium radon concentration and equilibrium time of LRS decrease exponentially with the increase of the rate of fresh air ventilation. In addition, the indoor radon concentration increases by accumulation with the decrease of the rate of fresh air ventilation. (authors)

  10. Report. no. 20. Sensory evaluation of indoor air quality

    DEFF Research Database (Denmark)

    Berglund, Birgitta; Bluyssen, Philomena; Clausen, Geo

    Human subjects are indispensable in the measurement of perceived indoor air quality. Chemical and physical methods of characterisation often are insensitive to odorous and sensory irritating air pollutants, or do not take account of combinations of singular pollutants in a biologically meaningful...... way. Therefore, sensory methods many times are the only or the preferred tool for evaluation of perceived indoor air quality. This report presents background to and advice on methodologies for sensory evaluation of perceived indoor air quality. It proposes methods which apply to source assessments...... as well as field investigations. The methods will assist in labelling of building materials, characterising air quality in indoor spaces, controlling ventilation performance, and measuring occupant responses in questionnaire field studies of the sick building syndrome. The proposed methods will enable...

  11. a Review of Recent Research in Indoor Modelling & Mapping

    Science.gov (United States)

    Gunduz, M.; Isikdag, U.; Basaraner, M.

    2016-06-01

    Indoor modeling and mapping has been an active area of research in last 20 years in order to tackle the problems related to positioning and tracking of people and objects indoors, and provides many opportunities for several domains ranging from emergency response to logistics in micro urban spaces. The outputs of recent research in the field have been presented in several scientific publications and events primarily related to spatial information science and technology. This paper summarizes the outputs of last 10 years of research on indoor modeling and mapping within a proper classification which covers 7 areas, i.e. Information Acquisition by Sensors, Model Definition, Model Integration, Indoor Positioning and LBS, Routing & Navigation Methods, Augmented and Virtual Reality Applications, and Ethical Issues. Finally, the paper outlines the current and future research directions and concluding remarks.

  12. Youth indoor tanning and skin cancer prevention: lessons from tobacco control.

    Science.gov (United States)

    Seidenberg, Andrew B; Mahalingam-Dhingra, Aditya; Weinstock, Martin A; Sinclair, Craig; Geller, Alan C

    2015-02-01

    Youth use of ultraviolet-emitting indoor tanning beds represents a present and emerging public health crisis. Nearly 30% of white female high school students report tanning indoors, and a quarter of high school tanners have used a tanning bed more than 20 times in the past year. Despite the significant health risks of tanning beds, including potentially deadly melanoma and eye problems, limited actions have been taken in the U.S. to protect youth. Tobacco control policies and campaigns, which have sharply reduced youth smoking, may provide a useful framework to control indoor tanning among young people. This article describes several evidence-based tobacco control strategies with potential applicability to indoor tanning within the context of the U.S. Further, current tobacco control policies and current indoor tanning policies in the U.S. are compared, and recommendations on how to curtail youth indoor tanning are discussed. Copyright © 2015 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  13. Geomagnetism-Aided Indoor Wi-Fi Radio-Map Construction via Smartphone Crowdsourcing.

    Science.gov (United States)

    Li, Wen; Wei, Dongyan; Lai, Qifeng; Li, Xianghong; Yuan, Hong

    2018-05-08

    Wi-Fi radio-map construction is an important phase in indoor fingerprint localization systems. Traditional methods for Wi-Fi radio-map construction have the problems of being time-consuming and labor-intensive. In this paper, an indoor Wi-Fi radio-map construction method is proposed which utilizes crowdsourcing data contributed by smartphone users. We draw indoor pathway map and construct Wi-Fi radio-map without requiring manual site survey, exact floor layout and extra infrastructure support. The key novelty is that it recognizes road segments from crowdsourcing traces by a cluster based on magnetism sequence similarity and constructs an indoor pathway map with Wi-Fi signal strengths annotated on. Through experiments in real world indoor areas, the method is proved to have good performance on magnetism similarity calculation, road segment clustering and pathway map construction. The Wi-Fi radio maps constructed by crowdsourcing data are validated to provide competitive indoor localization accuracy.

  14. Indoor Navigation from Point Clouds: 3d Modelling and Obstacle Detection

    Science.gov (United States)

    Díaz-Vilariño, L.; Boguslawski, P.; Khoshelham, K.; Lorenzo, H.; Mahdjoubi, L.

    2016-06-01

    In the recent years, indoor modelling and navigation has become a research of interest because many stakeholders require navigation assistance in various application scenarios. The navigational assistance for blind or wheelchair people, building crisis management such as fire protection, augmented reality for gaming, tourism or training emergency assistance units are just some of the direct applications of indoor modelling and navigation. Navigational information is traditionally extracted from 2D drawings or layouts. Real state of indoors, including opening position and geometry for both windows and doors, and the presence of obstacles is commonly ignored. In this work, a real indoor-path planning methodology based on 3D point clouds is developed. The value and originality of the approach consist on considering point clouds not only for reconstructing semantically-rich 3D indoor models, but also for detecting potential obstacles in the route planning and using these for readapting the routes according to the real state of the indoor depictured by the laser scanner.

  15. INDOOR NAVIGATION FROM POINT CLOUDS: 3D MODELLING AND OBSTACLE DETECTION

    Directory of Open Access Journals (Sweden)

    L. Díaz-Vilariño

    2016-06-01

    Full Text Available In the recent years, indoor modelling and navigation has become a research of interest because many stakeholders require navigation assistance in various application scenarios. The navigational assistance for blind or wheelchair people, building crisis management such as fire protection, augmented reality for gaming, tourism or training emergency assistance units are just some of the direct applications of indoor modelling and navigation. Navigational information is traditionally extracted from 2D drawings or layouts. Real state of indoors, including opening position and geometry for both windows and doors, and the presence of obstacles is commonly ignored. In this work, a real indoor-path planning methodology based on 3D point clouds is developed. The value and originality of the approach consist on considering point clouds not only for reconstructing semantically-rich 3D indoor models, but also for detecting potential obstacles in the route planning and using these for readapting the routes according to the real state of the indoor depictured by the laser scanner.

  16. A Realistic Human Exposure Assessment of Indoor Radon released from Groundwater

    International Nuclear Information System (INIS)

    Yu, Dong Han; Han, Moon Hee

    2002-01-01

    The work presents a realistic human exposure assessment of indoor radon released from groundwater in a house. At first, a two-compartment model is developed to describe the generation and transfer of radon in indoor air from groundwater. The model is used to estimate radon concentrations profile of indoor air in a house using by showering, washing clothes, and flushing toilets. Then, the study performs an uncertainty analysis of model input parameters to quantify the uncertainty in radon concentration profile. In order to estimate a daily internal dose of a specific tissue group in an adult through the inhalation of such indoor radon, a PBPK(Physiologically-Based Pharmaco-Kinetic) model is developed. Combining indoor radon profile and PBPK model is used to a realistic human assessment for such exposure. The results obtained from this study would be used to the evaluation of human risk by inhalation associated with the indoor radon released from groundwater

  17. Geomagnetism-Aided Indoor Wi-Fi Radio-Map Construction via Smartphone Crowdsourcing

    Directory of Open Access Journals (Sweden)

    Wen Li

    2018-05-01

    Full Text Available Wi-Fi radio-map construction is an important phase in indoor fingerprint localization systems. Traditional methods for Wi-Fi radio-map construction have the problems of being time-consuming and labor-intensive. In this paper, an indoor Wi-Fi radio-map construction method is proposed which utilizes crowdsourcing data contributed by smartphone users. We draw indoor pathway map and construct Wi-Fi radio-map without requiring manual site survey, exact floor layout and extra infrastructure support. The key novelty is that it recognizes road segments from crowdsourcing traces by a cluster based on magnetism sequence similarity and constructs an indoor pathway map with Wi-Fi signal strengths annotated on. Through experiments in real world indoor areas, the method is proved to have good performance on magnetism similarity calculation, road segment clustering and pathway map construction. The Wi-Fi radio maps constructed by crowdsourcing data are validated to provide competitive indoor localization accuracy.

  18. Role of dust alkalinity in acid mobilization of iron

    Directory of Open Access Journals (Sweden)

    A. Ito

    2010-10-01

    Full Text Available Atmospheric processing of mineral aerosols by acid gases (e.g., SO2, HNO3, N2O5, and HCl may play a key role in the transformation of insoluble iron (Fe in the oxidized or ferric (III form to soluble forms (e.g., Fe(II, inorganic soluble species of Fe(III, and organic complexes of iron. On the other hand, mineral dust particles have a potential of neutralizing the acidic species due to the alkaline buffer ability of carbonate minerals (e.g., CaCO3 and MgCO3. Here we demonstrate the impact of dust alkalinity on the acid mobilization of iron in a three-dimensional aerosol chemistry transport model that includes a mineral dissolution scheme. In our model simulations, most of the alkaline dust minerals cannot be entirely consumed by inorganic acids during the transport across the North Pacific Ocean. As a result, the inclusion of alkaline compounds in aqueous chemistry substantially limits the iron dissolution during the long-range transport to the North Pacific Ocean: only a small fraction of iron (<0.2% dissolves from hematite in the coarse-mode dust aerosols with 0.45% soluble iron initially. On the other hand, a significant fraction of iron (1–2% dissolves in the fine-mode dust aerosols due to the acid mobilization of the iron-containing minerals externally mixed with carbonate minerals. Consequently, the model quantitatively reproduces higher iron solubility in smaller particles as suggested by measurements over the Pacific Ocean. It implies that the buffering effect of alkaline content in dust aerosols might help to explain the inverse relationship between aerosol iron solubility and particle size. We also demonstrate that the iron solubility is sensitive to the chemical specification of iron-containing minerals in dust. Compared with the dust sources, soluble iron from combustion sources contributes to a relatively marginal effect for deposition of soluble iron over the North

  19. Method of forming magnetostrictive rods from rare earth-iron alloys

    Science.gov (United States)

    McMasters, O. Dale

    1986-09-02

    Rods of magnetrostructive alloys of iron with rare earth elements are formed by flowing a body of rare earth-iron alloy in a crucible enclosed in a chamber maintained under an inert gas atmosphere, forcing such molten rare-earth-iron alloy into a hollow mold tube of refractory material positioned with its lower end portion within the molten body by means of a pressure differential between the chamber and mold tube and maintaining a portion of the molten alloy in the crucible extending to a level above the lower end of the mold tube so that solid particles of higher melting impurities present in the alloy collect at the surface of the molten body and remain within the crucible as the rod is formed in the mold tube.

  20. Using random event simulation to evaluate the effectiveness of indoor sheltering during a sour gas release

    International Nuclear Information System (INIS)

    Wilson, D.

    2003-01-01

    In the event of sour gas releases to the atmosphere, there is a strong bias toward evacuation rather than sheltering-in-place. This paper described the critical factors in decision-making for shelter-in-place versus evacuation. These include: delay time expected before release begins; size of potential release, explosion or fire; expected duration; direction to safety for evacuation; the air tightness of the building; and, the number of people in the emergency response zone. A shelter-in-place decision chart developed by the Canadian Association of Fire Chiefs was presented. It shows the usual bias toward evacuation as the default position. It also shows the greatest drawbacks of sheltering-in-place. The main factor in maintaining the effectiveness of the building shelter is the rate of air infiltration into the building. Other issues to consider include: reactive versus passive chemicals in the release; light versus heavy gas releases; building type (houses, high-rise apartments, office buildings, or warehouses); tightness of building construction; whether to turn the house heating and air conditioning on or off during shelter; daytime versus nighttime conditions; and, cost factors. Equations for calculating indoor and outdoor toxic exposure to decide on shelter versus evacuation were also presented. It was concluded that the absence of peak concentrations dramatically reduce the risk of fatality to people sheltering indoors. Keeping people indoors is the best way to assure their safety for the first hour following a toxic release. 8 refs., 6 figs

  1. Medical diagnostics for indoor mold exposure.

    Science.gov (United States)

    Hurraß, Julia; Heinzow, Birger; Aurbach, Ute; Bergmann, Karl-Christian; Bufe, Albrecht; Buzina, Walter; Cornely, Oliver A; Engelhart, Steffen; Fischer, Guido; Gabrio, Thomas; Heinz, Werner; Herr, Caroline E W; Kleine-Tebbe, Jörg; Klimek, Ludger; Köberle, Martin; Lichtnecker, Herbert; Lob-Corzilius, Thomas; Merget, Rolf; Mülleneisen, Norbert; Nowak, Dennis; Rabe, Uta; Raulf, Monika; Seidl, Hans Peter; Steiß, Jens-Oliver; Szewszyk, Regine; Thomas, Peter; Valtanen, Kerttu; Wiesmüller, Gerhard A

    2017-04-01

    In April 2016, the German Society of Hygiene, Environmental Medicine and Preventative Medicine (Gesellschaft für Hygiene, Umweltmedizin und Präventivmedizin (GHUP)) together with other scientific medical societies, German and Austrian medical societies, physician unions and experts has provided an AWMF (Association of the Scientific Medical Societies) guideline 'Medical diagnostics for indoor mold exposure'. This guideline shall help physicians to advise and treat patients exposed indoors to mold. Indoor mold growth is a potential health risk, even without a quantitative and/or causal association between the occurrence of individual mold species and health effects. Apart from the allergic bronchopulmonary aspergillosis (ABPA) and the mycoses caused by mold, there is only sufficient evidence for the following associations between moisture/mold damages and different health effects: Allergic respiratory diseases, asthma (manifestation, progression, exacerbation), allergic rhinitis, exogenous allergic alveolitis and respiratory tract infections/bronchitis. In comparison to other environmental allergens, the sensitizing potential of molds is estimated to be low. Recent studies show a prevalence of sensitization of 3-10% in the total population of Europe. The evidence for associations to mucous membrane irritation and atopic eczema (manifestation, progression, exacerbation) is classified as limited or suspected. Inadequate or insufficient evidence for an association is given for COPD, acute idiopathic pulmonary hemorrhage in children, rheumatism/arthritis, sarcoidosis, and cancer. The risk of infections from indoor molds is low for healthy individuals. Only molds that are capable to form toxins can cause intoxications. The environmental and growth conditions and especially the substrate determine whether toxin formation occurs, but indoor air concentrations are always very low. In the case of indoor moisture/mold damages, everyone can be affected by odor effects and

  2. Methodology developed to make the Quebec indoor radon potential map

    International Nuclear Information System (INIS)

    Drolet, Jean-Philippe; Martel, Richard; Poulin, Patrick; Dessau, Jean-Claude

    2014-01-01

    This paper presents a relevant approach to predict the indoor radon potential based on the combination of the radiogeochemical data and the indoor radon measurements in the Quebec province territory (Canada). The Quebec ministry of health asked for such a map to identify the radon-prone areas to manage the risk for the population related to indoor radon exposure. Three radiogeochemical criteria including (1) equivalent uranium (eU) concentration from airborne surface gamma-ray surveys, (2) uranium concentration measurements in sediments, (3) bedrock and surficial geology were combined with 3082 basement radon concentration measurements to identify the radon-prone areas. It was shown that it is possible to determine thresholds for the three criteria that implied statistically significant different levels of radon potential using Kruskal–Wallis one way analyses of variance by ranks. The three discretized radiogeochemical datasets were combined into a total predicted radon potential that sampled 98% of the studied area. The combination process was also based on Kruskal–Wallis one way ANOVA. Four statistically significant different predicted radon potential levels were created: low, medium, high and very high. Respectively 10 and 13% of the dwellings exceed the Canadian radon guideline of 200 Bq/m 3 in low and medium predicted radon potentials. These proportions rise up to 22 and 45% respectively for high and very high predicted radon potentials. This predictive map of indoor radon potential based on the radiogeochemical data was validated using a map of confirmed radon exposure in homes based on the basement radon measurements. It was shown that the map of predicted radon potential based on the radiogeochemical data was reliable to identify radon-prone areas even in zones where no indoor radon measurement exists. - Highlights: • 5 radiogeochemical datasets were used to map the geogenic indoor radon potential. • An indoor radon potential was determined for each

  3. Measurements of indoor radon concentration in Libyan cities

    International Nuclear Information System (INIS)

    Elarabiy, S. F.; Khalifa, M.; Misrati, N.; Chahboune, N.; Ahmed, M.

    2012-12-01

    Studies confirm that the risk of exposure to indor radon is attributable to lung cancer worldwide. The relationship between radon exposure and cancer is a linear one which necessitates for need for measurements of indoor radon concentration. This paper presents the results of measurements of indoor radon in several libya cities using CR-39 plastic. The results showed that the average radon concentration in the cities of Tripoli, Al-harcha and Alrajaban were 48.8 Bg/m 3 , 51.4 Bg/m 3 and 55.5 Bg/m 3 respectively. The average indoor radon concentration in Libya is low comparing with other studies. (Author)

  4. Indoor environment and pupils' health in primary schools

    NARCIS (Netherlands)

    van Dijken, F; Bronswijk, van J.E.M.H.; Sundell, J.

    2006-01-01

    Dutch children are legally bound to spend 15% of their time in a school setting. The indoor environment in Dutch primary schools is known to be substandard. However, it is unclear to what extent the health of pupils is affected by the indoor school environment. The paper aims to assess the

  5. Iron Refractory Iron Deficiency Anaemia: A Rare Cause of Iron Deficiency Anaemia

    LENUS (Irish Health Repository)

    McGrath, T

    2018-01-01

    We describe the case of a 17-month-old boy with a hypochromic microcytic anaemia, refractory to oral iron treatment. After exclusion of dietary and gastrointestinal causes of iron deficiency, a genetic cause for iron deficiency was confirmed by finding two mutations in the TMPRSS6 gene, consistent with a diagnosis of iron-refractory iron deficiency anaemia (IRIDA).

  6. Chemical Reduction Synthesis of Iron Aluminum Powders

    Science.gov (United States)

    Zurita-Méndez, N. N.; la Torre, G. Carbajal-De; Ballesteros-Almanza, L.; Villagómez-Galindo, M.; Sánchez-Castillo, A.; Espinosa-Medina, M. A.

    In this study, a chemical reduction synthesis method of iron aluminum (FeAl) nano-dimensional intermetallic powders is described. The process has two stages: a salt reduction and solvent evaporation by a heat treatment at 1100°C. The precursors of the synthesis are ferric chloride, aluminum foil chips, a mix of Toluene/THF in a 75/25 volume relationship, and concentrated hydrochloric acid as initiator of the reaction. The reaction time was 20 days, the product obtained was dried at 60 °C for 2 h and calcined at 400, 800, and 1100 °C for 4 h each. To characterize and confirm the obtained synthesis products, X-Ray Diffraction (XRD), and Scanning Electron Microscopy (SEM) techniques were used. The results of morphology and chemical characterization of nano-dimensional powders obtained showed a formation of agglomerated particles of a size range of approximately 150 nm to 1.0 μm. Composition of powders was identified as corundum (Al2O3), iron aluminide (FeAl3), and iron-aluminum oxides (Fe0. 53Al0. 47)2O3 phases. The oxide phases formation were associated with the reaction of atmospheric concentration-free oxygen during synthesis and sintering steps, reducing the concentration of the iron aluminum phase.

  7. Indoor air and human health: major indoor air pollutants and their health implications

    International Nuclear Information System (INIS)

    1984-01-01

    This publication is a collection of abstracts of papers presented at the Indoor Air and Human Health symposium. Session titles include: Radon, Microorganisms, Passive Cigarette Smoke, Combustion Products, Organics, and Panel and Audience Discussion

  8. Indoor air and human health: major indoor air pollutants and their health implications

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    This publication is a collection of abstracts of papers presented at the Indoor Air and Human Health symposium. Session titles include: Radon, Microorganisms, Passive Cigarette Smoke, Combustion Products, Organics, and Panel and Audience Discussion.

  9. A survey of indoor radon and particular concentration

    International Nuclear Information System (INIS)

    Ohta, Yukiko

    1993-01-01

    Lung disease risk from inhalation of radon can be enhanced by the presence of particular pollutants in indoor air. The indoor concentration of radon and particulates were measured in homes, a department store, and offices in a high building in Tokyo metropolis, as well as in homes in both northern and western Japan. Passive radon monitors were located in living rooms and offices for more than three months at 99 sites during the winter of 1988 and 1989. Indoor radon concentration ranged from 11.1 Bq/m 3 to 148 Bq/m 3 (n=99) and averaged value S.D. was 36.5±14.2 Bq/m 3 . However, the average concentration in air conditional buildings was 21.8±9.51 Bq/m 3 (n=17). Simultaneously at 65 of the radon sites, indoor particulates were collected using personal dust samplers by impaction methods. Deposited particulate concentrations on the sampler were measured and calculated in a unit of μm/m 3 . Concentrations were determined for particle sizes above and below 2.5 μm, for both smoking or non smoking sites. Consequently, concentration of particle size below 2.5 μm was high in smoking rooms. Finally, it was considered that smoking was a complex indoor pollutant as adherence of radon daughter to aerosols. (author)

  10. Addiction to indoor tanning: relation to anxiety, depression, and substance use.

    Science.gov (United States)

    Mosher, Catherine E; Danoff-Burg, Sharon

    2010-04-01

    To assess the prevalence of addiction to indoor tanning among college students and its association with substance use and symptoms of anxiety and depression. Two written measures, the CAGE (Cut down, Annoyed, Guilty, Eye-opener) Questionnaire, used to screen for alcoholism, and the Diagnostic and Statistical Manual of Mental Disorders (Fourth Edition, Text Revision) (DSM-IV-TR) criteria for substance-related disorders, were modified to evaluate study participants for addiction to indoor tanning. Standardized self-report measures of anxiety, depression, and substance use also were administered. A large university (approximately 18 000 students) in the northeastern United States. A total of 421 college students were recruited from September through December 2006. Self-reported addiction to indoor tanning, substance use, and symptoms of anxiety and depression. Among 229 study participants who had used indoor tanning facilities, 90 (39.3%) met DSM-IV-TR criteria and 70 (30.6%) met CAGE criteria for addiction to indoor tanning. Students who met DSM-IV-TR and CAGE criteria for addiction to indoor tanning reported greater symptoms of anxiety and greater use of alcohol, marijuana, and other substances than those who did not meet these criteria. Depressive symptoms did not significantly vary by indoor tanning addiction status. Findings suggest that interventions to reduce skin cancer risk should address the addictive qualities of indoor tanning for a minority of individuals and the relationship of this behavior to other addictions and affective disturbance.

  11. Size-Dependent Specific Surface Area of Nanoporous Film Assembled by Core-Shell Iron Nanoclusters

    Directory of Open Access Journals (Sweden)

    Jiji Antony

    2006-01-01

    Full Text Available Nanoporous films of core-shell iron nanoclusters have improved possibilities for remediation, chemical reactivity rate, and environmentally favorable reaction pathways. Conventional methods often have difficulties to yield stable monodispersed core-shell nanoparticles. We produced core-shell nanoclusters by a cluster source that utilizes combination of Fe target sputtering along with gas aggregations in an inert atmosphere at 7∘C. Sizes of core-shell iron-iron oxide nanoclusters are observed with transmission electron microscopy (TEM. The specific surface areas of the porous films obtained from Brunauer-Emmett-Teller (BET process are size-dependent and compared with the calculated data.

  12. INTEGRATION OF GIS AND BIM FOR INDOOR GEOVISUAL ANALYTICS

    Directory of Open Access Journals (Sweden)

    B. Wu

    2016-06-01

    Full Text Available This paper presents an endeavour of integration of GIS (Geographical Information System and BIM (Building Information Modelling for indoor geovisual analytics. The merits of two types of technologies, GIS and BIM are firstly analysed in the context of indoor environment. GIS has well-developed capabilities of spatial analysis such as network analysis, while BIM has the advantages for indoor 3D modelling and dynamic simulation. This paper firstly investigates the important aspects for integrating GIS and BIM. Different data standards and formats such as the IFC (Industry Foundation Classes and GML (Geography Markup Language are discussed. Their merits and limitations in data transformation between GIS and BIM are analysed in terms of semantic and geometric information. An optimized approach for data exchange between GIS and BIM datasets is then proposed. After that, a strategy of using BIM for 3D indoor modelling, GIS for spatial analysis, and BIM again for visualization and dynamic simulation of the analysis results is presented. Based on the developments, this paper selects a typical problem, optimized indoor emergency evacuation, to demonstrate the integration of GIS and BIM for indoor geovisual analytics. The block Z of the Hong Kong Polytechnic University is selected as a test site. Detailed indoor and outdoor 3D models of the block Z are created using a BIM software Revit. The 3D models are transferred to a GIS software ArcGIS to carry out spatial analysis. Optimized evacuation plans considering dynamic constraints are generated based on network analysis in ArcGIS assuming there is a fire accident inside the building. The analysis results are then transferred back to BIM software for visualization and dynamic simulation. The developed methods and results are of significance to facilitate future development of GIS and BIM integrated solutions in various applications.

  13. ASSOCIATIONS BETWEEN SEASONAL SLEEP CHANGE AND INDOOR TANNING1,2

    Science.gov (United States)

    CULNAN, ELIZABETH; KLOSS, JACQUELINE D.; DARLOW, SUSAN; HECKMAN, CAROLYN J.

    2015-01-01

    Summary Identification of risk factors for indoor tanning may ultimately aid the development of better indoor tanning prevention strategies, which is pertinent given the association between indoor tanning and skin cancer. This study aimed to examine the relationship between seasonal sleep change and indoor tanning. Women tanners (N= 139) completed self-report measures including items relating to seasonal sleep changes, seasonal affective disorder (SAD), reasons for tanning, tanning during the winter months, and the Tanning Pathology Scale (TAPS), which measures problematic tanning motives and symptoms of tanning dependence. It was hypothesized that seasonal sleep change and SAD would be associated with greater indoor tanning during the winter, more tanning to improve mood and to relax, and higher scores on the TAPS. Findings indicated that more seasonal sleep change was associated with tanning to improve mood and higher scores on the TAPS. Similarly, the presence of SAD was related to tanning to improve mood, tanning to relax, and more problematic tanning. PMID:25730744

  14. Indoor environmental quality in French dwellings and building characteristics

    Science.gov (United States)

    Langer, Sarka; Ramalho, Olivier; Derbez, Mickaël; Ribéron, Jacques; Kirchner, Severine; Mandin, Corinne

    2016-03-01

    A national survey on indoor environmental quality covering 567 residences in mainland France was performed during 2003-2005. The measured parameters were temperature, relative humidity, CO2, and the indoor air pollutants: fourteen individual volatile organic compounds (VOC), four aldehydes and particulate matter PM10 and PM2.5. The measured indoor concentrations were analyzed for correlations with the building characteristics: type of dwelling, period of construction, dwelling location, type of ventilation system, building material, attached garage and retrofitting. The median night time air exchange rate (AER) for all dwellings was 0.44 h-1. The night time AER was higher in apartments (median = 0.49 h-1) than in single-family houses (median = 0.41 h-1). Concentration of formaldehyde was approximately 30% higher in dwellings built after 1990 compared with older ones; it was higher in dwellings with mechanical ventilation and in concrete buildings. The VOC concentrations depended on the building characteristics to various extents. The sampling season influenced the majority of the indoor climate parameters and the concentrations of the air pollutants to a higher degree than the building characteristics. Multivariate linear regression models revealed that the indoor-outdoor difference in specific humidity, a proxy for number of occupants and their indoor activities, remained a significant predictor for most gaseous and particulate air pollutants. The other strong predictors were outdoor concentration, smoking, attached garage and AER (in descending order).

  15. Reference Guide. Indoor Air Quality Tools for Schools

    Science.gov (United States)

    US Environmental Protection Agency, 2009

    2009-01-01

    Understanding the importance of good indoor air quality (IAQ) in schools is the backbone of developing an effective Indoor Air Quality (IAQ) program. Poor IAQ can lead to a large variety of health problems and potentially affect comfort, concentration, and staff/student performance. In recognition of tight school budgets, this guidance is designed…

  16. Total volatile organic compounds (TVOC) in indoor air quality investigations

    DEFF Research Database (Denmark)

    Mølhave, L.; Clausen, Geo; Berglund, B.

    1997-01-01

    The amount of volatile organic compounds (VOCs) in indoor air, usually called TVOC (total volatile organic compounds), has been measured using different definitions and techniques which yield different results. This report recommends a definition of TVOC referring to a specified range of VOCs...... for characterizing indoor pollution and for improving source control as required from the points of view of health, comfort, energy efficiency and sustainability. (C) Indoor Air (1997)....

  17. Ultra Wideband Indoor Positioning Technologies: Analysis and Recent Advances.

    Science.gov (United States)

    Alarifi, Abdulrahman; Al-Salman, AbdulMalik; Alsaleh, Mansour; Alnafessah, Ahmad; Al-Hadhrami, Suheer; Al-Ammar, Mai A; Al-Khalifa, Hend S

    2016-05-16

    In recent years, indoor positioning has emerged as a critical function in many end-user applications; including military, civilian, disaster relief and peacekeeping missions. In comparison with outdoor environments, sensing location information in indoor environments requires a higher precision and is a more challenging task in part because various objects reflect and disperse signals. Ultra WideBand (UWB) is an emerging technology in the field of indoor positioning that has shown better performance compared to others. In order to set the stage for this work, we provide a survey of the state-of-the-art technologies in indoor positioning, followed by a detailed comparative analysis of UWB positioning technologies. We also provide an analysis of strengths, weaknesses, opportunities, and threats (SWOT) to analyze the present state of UWB positioning technologies. While SWOT is not a quantitative approach, it helps in assessing the real status and in revealing the potential of UWB positioning to effectively address the indoor positioning problem. Unlike previous studies, this paper presents new taxonomies, reviews some major recent advances, and argues for further exploration by the research community of this challenging problem space.

  18. Ultra Wideband Indoor Positioning Technologies: Analysis and Recent Advances

    Directory of Open Access Journals (Sweden)

    Abdulrahman Alarifi

    2016-05-01

    Full Text Available In recent years, indoor positioning has emerged as a critical function in many end-user applications; including military, civilian, disaster relief and peacekeeping missions. In comparison with outdoor environments, sensing location information in indoor environments requires a higher precision and is a more challenging task in part because various objects reflect and disperse signals. Ultra WideBand (UWB is an emerging technology in the field of indoor positioning that has shown better performance compared to others. In order to set the stage for this work, we provide a survey of the state-of-the-art technologies in indoor positioning, followed by a detailed comparative analysis of UWB positioning technologies. We also provide an analysis of strengths, weaknesses, opportunities, and threats (SWOT to analyze the present state of UWB positioning technologies. While SWOT is not a quantitative approach, it helps in assessing the real status and in revealing the potential of UWB positioning to effectively address the indoor positioning problem. Unlike previous studies, this paper presents new taxonomies, reviews some major recent advances, and argues for further exploration by the research community of this challenging problem space.

  19. Indoor air-quality measurements in energy-efficient residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Berk, J.V.; Hollowell, C.D.; Pepper, J.H.; Young, R.

    1980-05-01

    The potential impact on indoor air quality of energy-conserving measures that reduce ventilation is being assessed in a field-monitoring program conducted by the Lawrence Berkeley Laboratory. Using a mobile laboratory, on-site monitoring of infiltration rate, carbon dioxide, carbon monoxide, nitrogen dioxide, nitric oxide, ozone, sulfur dioxide, formaldehyde, total aldehydes, and particulates was conducted in three houses designed to be energy-efficient. Preliminary results show that energy-conserving design features that reduce air-exchange rates compromise indoor air quality; specifically, indoor levels of several pollutants were found to exceed levels detected outdoors. Although the indoor levels of most pollutants are within limits established by present outdoor air-quality standards, considerable work remains to be accomplished before health-risk effects can be accurately assessed and broad-scale regulatory guidelines revised to comply with energy-conservation goals.

  20. A REVIEW OF RECENT RESEARCH IN INDOOR MODELLING & MAPPING

    Directory of Open Access Journals (Sweden)

    M. Gunduz

    2016-06-01

    Full Text Available Indoor modeling and mapping has been an active area of research in last 20 years in order to tackle the problems related to positioning and tracking of people and objects indoors, and provides many opportunities for several domains ranging from emergency response to logistics in micro urban spaces. The outputs of recent research in the field have been presented in several scientific publications and events primarily related to spatial information science and technology. This paper summarizes the outputs of last 10 years of research on indoor modeling and mapping within a proper classification which covers 7 areas, i.e. Information Acquisition by Sensors, Model Definition, Model Integration, Indoor Positioning and LBS, Routing & Navigation Methods, Augmented and Virtual Reality Applications, and Ethical Issues. Finally, the paper outlines the current and future research directions and concluding remarks.

  1. Unusually amplified summer or winter indoor levels of radon

    International Nuclear Information System (INIS)

    Gammage, R.B.; Dudney, C.S.; Wilson, D.L.

    1993-01-01

    The ratios of winter/summer indoor radon levels for houses in different regions of the southern Appalachians are characterized by individual log-normal distributions with geometric means both above and below unity. In some counties and cities, subpopulations of houses have unusually exaggerated winter/summer ratios of indoor radon, as well as high indoor radon levels, during periods of either warm or cool weather. It is proposed that in many instances, houses are communicating with larger than normal underground reservoirs of radon-bearing air in hilly karst terrains; differences between the outdoor and underground air temperatures are believed to provide density gradients producing aerostatic pressure differences for seasonally directed underground transport and subsequently elevated indoor radon. These seasonal movements of air are analogous to the well-known underground chimney effects, which produce interzonal flows of air inside caves

  2. Interior shadings for office indoor visual comfort in humid climate region

    Science.gov (United States)

    Dinapradipta, Asri; Sudarma, Erwin; Defiana, Ima; Erwindi, Collinthia

    2018-03-01

    As part of the fenestration system, the interior shadings have also a role to control the indoor environment to maintain indoor visual comfort. As the occupants have personal access to control these, their control behavior then, might enhance or even worsen indoor comfort performance. The controlling behavior might not only influence indoor comfort performance but can also indicate the success or failure of interior shading as a control device element. This paper is intended to report control behavior patterns, as represented by the variety of the slats’ openings of two types of interior shading i.e. Venetian and Vertical blinds and to analyze these on the concurrent impacts to indoor office building’s indoor illuminance and luminance distribution. The purpose of this research is to figure out the shading control patterns as well as to examine the effectiveness of these two types of interior shadings to control indoor visual environment. This study is a quantitative research using experimentation on the slats’ opening of two types of shadings at two identical office rooms. The research results suggested that both types of blinds seem unsuitable for gaining proper illumination values at work planes in humid tropics area. However, these shadings demonstrate good performance for luminance distribution except for that of the closed Venetian blinds.

  3. Impact of operating wood-burning fireplace ovens on indoor air quality.

    Science.gov (United States)

    Salthammer, Tunga; Schripp, Tobias; Wientzek, Sebastian; Wensing, Michael

    2014-05-01

    The use of combustion heat sources like wood-burning fireplaces has regained popularity in the past years due to increasing energy costs. While the outdoor emissions from wood ovens are strictly regulated in Germany, the indoor release of combustion products is rarely considered. Seven wood burning fireplaces were tested in private homes between November 2012 and March 2013. The indoor air quality was monitored before, during and after operation. The following parameters were measured: ultra-fine particles (5.6-560 nm), fine particles (0.3-20 μm), PM2.5, NOx, CO, CO2, formaldehyde, acetaldehyde, volatile organic compounds (VOCs) and benzo[a]pyrene (BaP). Most ovens were significant sources of particulate matter. In some cases, an increase of benzene and BaP concentrations was observed in the indoor air. The results illustrate that wood-burning fireplaces are potential sources of indoor air contaminants, especially ultra-fine particles. Under the aspect of lowering indoor air exchange rates and increasing the use of fuels with a net zero-carbon footprint, indoor combustion sources are an important topic for the future. With regards to consumer safety, product development and inspection should consider indoor air quality in addition to the present fire protection requirements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Reflections on the State of Research: Indoor Environmental Quality

    DEFF Research Database (Denmark)

    Clausen, Geo; Bekö, Gabriel; Corsi, Richard

    2011-01-01

    that with parallel research and writing efforts culminating with internal review and revision cycles. In this paper, we present our choices for the most important research findings on indoor environmental quality from the past three decades followed by a discussion of the most important research questions in our......More than 30 years after the First International Indoor Climate Symposium, ten researchers from the USA, Slovakia, Sweden, and Denmark gathered to review the current status of indoor environmental research. We initiated our review with discussions during the 1-day meeting and followed...

  5. A 2-year study of seasonal indoor radon variations in northern Virginia

    International Nuclear Information System (INIS)

    Mose, D.G.; Mushrush, G.W.; Chrosniak, C.E.

    1991-01-01

    The concentrations of indoor radon in the basements of homes located in northern Virginia average about 1.4 times the first-floor radon concentrations. Basement indoor radon concentrations exhibit seasonal variations that can be related to home use patterns of the occupants. Little indoor radon difference was seen between homes that have concrete block basement walls and poured concrete basement walls, but homes that use oil or gas furnaces for heating have ∼ 25% lower indoor radon than homes that use electrical heating systems. Particular geological units seem to be associated with elevated indoor radon concentrations, and several units are associated with indoor radon concentrations that exceed 4 pCi/l (the U.S. Environmental Agency action level) at some time in more than 40% of the homes. Comparative studies between indoor radon and total gamma aeroradioactivity show that aeroradioactivity can be accurately used to estimate community radon hazards. When combined with information about the home heating system, geology and aeroradioactivity can be used to identify problem homes

  6. Rethinking Indoor Localization Solutions Towards the Future of Mobile Location-Based Services

    Science.gov (United States)

    Guney, C.

    2017-11-01

    Satellite navigation systems with GNSS-enabled devices, such as smartphones, car navigation systems, have changed the way users travel in outdoor environment. GNSS is generally not well suited for indoor location and navigation because of two reasons: First, GNSS does not provide a high level of accuracy although indoor applications need higher accuracies. Secondly, poor coverage of satellite signals for indoor environments decreases its accuracy. So rather than using GNSS satellites within closed environments, existing indoor navigation solutions rely heavily on installed sensor networks. There is a high demand for accurate positioning in wireless networks in GNSS-denied environments. However, current wireless indoor positioning systems cannot satisfy the challenging needs of indoor location-aware applications. Nevertheless, access to a user's location indoors is increasingly important in the development of context-aware applications that increases business efficiency. In this study, how can the current wireless location sensing systems be tailored and integrated for specific applications, like smart cities/grids/buildings/cars and IoT applications, in GNSS-deprived areas.

  7. RETHINKING INDOOR LOCALIZATION SOLUTIONS TOWARDS THE FUTURE OF MOBILE LOCATION-BASED SERVICES

    Directory of Open Access Journals (Sweden)

    C. Guney

    2017-11-01

    Full Text Available Satellite navigation systems with GNSS-enabled devices, such as smartphones, car navigation systems, have changed the way users travel in outdoor environment. GNSS is generally not well suited for indoor location and navigation because of two reasons: First, GNSS does not provide a high level of accuracy although indoor applications need higher accuracies. Secondly, poor coverage of satellite signals for indoor environments decreases its accuracy. So rather than using GNSS satellites within closed environments, existing indoor navigation solutions rely heavily on installed sensor networks. There is a high demand for accurate positioning in wireless networks in GNSS-denied environments. However, current wireless indoor positioning systems cannot satisfy the challenging needs of indoor location-aware applications. Nevertheless, access to a user’s location indoors is increasingly important in the development of context-aware applications that increases business efficiency. In this study, how can the current wireless location sensing systems be tailored and integrated for specific applications, like smart cities/grids/buildings/cars and IoT applications, in GNSS-deprived areas.

  8. Iron speciation of airborne subway particles by the combined use of energy dispersive electron probe X-ray microanalysis and Raman microspectrometry.

    Science.gov (United States)

    Eom, Hyo-Jin; Jung, Hae-Jin; Sobanska, Sophie; Chung, Sang-Gwi; Son, Youn-Suk; Kim, Jo-Chun; Sunwoo, Young; Ro, Chul-Un

    2013-11-05

    Quantitative energy-dispersive electron probe X-ray microanalysis (ED-EPMA), known as low-Z particle EPMA, and Raman microspectrometry (RMS) were applied in combination for an analysis of the iron species in airborne PM10 particles collected in underground subway tunnels. Iron species have been reported to be a major chemical species in underground subway particles generated mainly from mechanical wear and friction processes. In particular, iron-containing particles in subway tunnels are expected to be generated with minimal outdoor influence on the particle composition. Because iron-containing particles have different toxicity and magnetic properties depending on their oxidation states, it is important to determine the iron species of underground subway particles in the context of both indoor public health and control measures. A recently developed analytical methodology, i.e., the combined use of low-Z particle EPMA and RMS, was used to identify the chemical species of the same individual subway particles on a single particle basis, and the bulk iron compositions of airborne subway particles were also analyzed by X-ray diffraction. The majority of airborne subway particles collected in the underground tunnels were found to be magnetite, hematite, and iron metal. All the particles collected in the tunnels of underground subway stations were attracted to permanent magnets due mainly to the almost ubiquitous ferrimagnetic magnetite, indicating that airborne subway particles can be removed using magnets as a control measure.

  9. How to Create Healthy Indoor Environments in Schools

    Science.gov (United States)

    Rhodes, Diane; Di Nella, Frank

    2012-01-01

    A green and healthy indoor environment should be a fundamental concern in the place where kids learn and grow. Good indoor air quality (IAQ) has been shown to have positive effects on student and staff productivity, performance, comfort and attendance. Conversely, poor IAQ in classrooms--caused by mold and moisture issues, problems with HVAC…

  10. INDOOR AIR QUALITY AND INHALATION EXPOSURE - SIMULATION TOOL KIT

    Science.gov (United States)

    A Microsoft Windows-based indoor air quality (IAQ) simulation software package is presented. Named Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure, or IAQX for short, this package complements and supplements existing IAQ simulation programs and is desi...

  11. Fracture toughness of borides formed on boronized ductile iron

    International Nuclear Information System (INIS)

    Sen, Ugur; Sen, Saduman; Koksal, Sakip; Yilmaz, Fevzi

    2005-01-01

    In this study, fracture toughness properties of boronized ductile iron were investigated. Boronizing was realized in a salt bath consisting of borax, boric acid and ferro-silicon. Boronizing heat treatment was carried out between 850 and 950 deg. C under the atmospheric pressure for 2-8 h. Borides e.g. FeB, Fe 2 B formed on ductile iron was verified by X-ray diffraction (XRD) analysis, SEM and optical microscope. Experimental results revealed that longer boronizing time resulted in thicker boride layers. Optical microscope cross-sectional observation of borided layers showed dentricular morphology. Both microhardness and fracture toughness of borided surfaces were measured via Vickers indenter. The harnesses of borides formed on the ductile iron were in the range of 1160-2140 HV 0.1 and fracture toughness were in the range of 2.19-4.47 MPa m 1/2 depending on boronizing time and temperature

  12. Radiation exposure of man in the indoor environment

    International Nuclear Information System (INIS)

    Steinhaeusler, F.; Pohl, E.

    1982-01-01

    Indoor exposure of man represents the major component of the dose from the natural radiation environment (NRE). The different sources of the NRE and their complex superposition are discussed. Due to the use of radiologically disadvantageous material in or near the building, radon-rich tap water, specific architectural styles and decreased ventilation rates NRE-levels indoors have been found to even exceed the upper limit for professional exposure. The inadequacy of the existing international regulatory framework and specific local problems resulted in the establishment of national exposure limits. In general, no remedial action is recommended at levels below 50 μR/h for external gamma radiation, 10 mWL for internal radon daughter exposure. Several technical countermeasures reducing indoor gamma dose rates and radon levels have been developed for existing buildings. However, the use of some of the techniques is limited due to low cost-effectiveness or lack of long-term stability. Different techniques in order to achieve low indoor exposures for new buildings and financial aspects associated the application of radiation protection concepts are discussed

  13. Control of indoor radon and radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.

    1985-05-01

    There are three general categories of techniques for the control of radon and radon progeny concentrations in indoor air - restriction of radon entry, reduction of indoor radon concentrations by ventilation or air cleaning, and removal of airborne radon progeny. The predominant radon entry process in most residences appears to be pressure driven flow of soil gas through cracks or other openings in the basement, slab, or subfloor. Sealing these openings or ventilation of the subslab or subfloor space are methods of reducing radon entry rates. Indoor radon concentrations may be reduced by increased ventilation. The use of charcoal filters for removal of radon gas in the indoor air by adsorption has also been proposed. Concentrations of radon progeny, which are responsible for most of the health risks associated with radon exposures, can be controlled by use of electrostatic or mechanical filtration. Air circulation can also reduce radon progeny concentrations in certain cases. This paper reviews the application and limitations of each of these control measures and discusses recent experimental results

  14. Indoor-Outdoor Detection Using a Smart Phone Sensor.

    Science.gov (United States)

    Wang, Weiping; Chang, Qiang; Li, Qun; Shi, Zesen; Chen, Wei

    2016-09-22

    In the era of mobile internet, Location Based Services (LBS) have developed dramatically. Seamless Indoor and Outdoor Navigation and Localization (SNAL) has attracted a lot of attention. No single positioning technology was capable of meeting the various positioning requirements in different environments. Selecting different positioning techniques for different environments is an alternative method. Detecting the users' current environment is crucial for this technique. In this paper, we proposed to detect the indoor/outdoor environment automatically without high energy consumption. The basic idea was simple: we applied a machine learning algorithm to classify the neighboring Global System for Mobile (GSM) communication cellular base station's signal strength in different environments, and identified the users' current context by signal pattern recognition. We tested the algorithm in four different environments. The results showed that the proposed algorithm was capable of identifying open outdoors, semi-outdoors, light indoors and deep indoors environments with 100% accuracy using the signal strength of four nearby GSM stations. The required hardware and signal are widely available in our daily lives, implying its high compatibility and availability.

  15. Indoor-Outdoor Detection Using a Smart Phone Sensor

    Directory of Open Access Journals (Sweden)

    Weiping Wang

    2016-09-01

    Full Text Available In the era of mobile internet, Location Based Services (LBS have developed dramatically. Seamless Indoor and Outdoor Navigation and Localization (SNAL has attracted a lot of attention. No single positioning technology was capable of meeting the various positioning requirements in different environments. Selecting different positioning techniques for different environments is an alternative method. Detecting the users’ current environment is crucial for this technique. In this paper, we proposed to detect the indoor/outdoor environment automatically without high energy consumption. The basic idea was simple: we applied a machine learning algorithm to classify the neighboring Global System for Mobile (GSM communication cellular base station’s signal strength in different environments, and identified the users’ current context by signal pattern recognition. We tested the algorithm in four different environments. The results showed that the proposed algorithm was capable of identifying open outdoors, semi-outdoors, light indoors and deep indoors environments with 100% accuracy using the signal strength of four nearby GSM stations. The required hardware and signal are widely available in our daily lives, implying its high compatibility and availability.

  16. Wi-Fi/MARG Integration for Indoor Pedestrian Localization.

    Science.gov (United States)

    Tian, Zengshan; Jin, Yue; Zhou, Mu; Wu, Zipeng; Li, Ze

    2016-12-10

    With the wide deployment of Wi-Fi networks, Wi-Fi based indoor localization systems that are deployed without any special hardware have caught significant attention and have become a currently practical technology. At the same time, the Magnetic, Angular Rate, and Gravity (MARG) sensors installed in commercial mobile devices can achieve highly-accurate localization in short time. Based on this, we design a novel indoor localization system by using built-in MARG sensors and a Wi-Fi module. The innovative contributions of this paper include the enhanced Pedestrian Dead Reckoning (PDR) and Wi-Fi localization approaches, and an Extended Kalman Particle Filter (EKPF) based fusion algorithm. A new Wi-Fi/MARG indoor localization system, including an Android based mobile client, a Web page for remote control, and a location server, is developed for real-time indoor pedestrian localization. The extensive experimental results show that the proposed system is featured with better localization performance, with the average error 0.85 m, than the one achieved by using the Wi-Fi module or MARG sensors solely.

  17. Feasibility study on mental healthcare using indoor plants for office workers

    Science.gov (United States)

    Kubota, Tsuyoshi; Matsumoto, Hiroshi; Genjo, Kaori; Nakano, Takaoki

    2017-10-01

    In recent years, it has become a problem that office workers' stresses affect their intellectual productivity. As one of strategies mitigating the stress while working, many studies on the effect of indoor plants introduced into the office have been conducted. The psychological and physiological effects of indoor plants have been expected to mitigate the office workers' stresses. Also, the effects of green amenities such as improvement of productivity, control of the indoor thermal environment, relaxation and recovery of visual fatigue, and improvement of air quality have been expected. In this study, a field investigation on the green amenity effects of indoor plants on office workers' psychological and physiological responses in an actual office was conducted and discussed. This paper describes the measurement results of the physical environment and workers' psychological and physiological responses under the condition with shelves installed with indoor plants in an office room. It was suggested that indoor plants such as mint, basil and begonia, and a combination of red and green plants were effective for mitigating worker's stresses.

  18. Indoor External Radiation Risk in Densely Populated Regions of Southern Nigeria

    Science.gov (United States)

    Ife-Adediran, Oluwatobi O.; Uwadiae, Iyobosa B.

    2018-05-01

    It is known that certain types of building materials contain significant concentrations of natural radionuclides; consequently, exposure to indoor background radiation is from the combined radioactivity from the soil as well as building materials; indoor exposures therefore have higher radiation hazard potentials than outdoor exposures in this regard and hence, need to be monitored. In this paper, an evaluation of background ionizing radiation from different buildings in Lagos and Ibadan, Southwestern Nigeria was carried out to determine the exposure rate of the general public to indoor ionizing radiation. 630 in situ measurements from the different buildings were taken using a Geiger Muller counter (model GQ-320 Plus). The indoor dose rates (i.e., 50-120 nGy/h) were within the world average values while the Annual Effective Dose for most of the buildings were above the world average AED for indoor gamma exposure from building materials. The mean AED for Lagos and Ibadan due to indoor exposures were 0.37 and 0.39 mSv/y with Excess Lifetime Cancer Risk of 0.99E-3 and 1.05E-3, respectively.

  19. Distribution of indoor radon levels in Mexico

    CERN Document Server

    Espinosa, G; Rickards, J; Gammage, R B

    1999-01-01

    Our laboratory has carried out a systematic monitoring and evaluation of indoor radon concentration levels in Mexico for ten years. The results of the distribution of indoor radon levels for practically the entire country are presented, together with information on geological characteristics, population density, socioeconomic levels of the population, and architectural styles of housing. The measurements of the radon levels were made using the passive method of nuclear tracks in solids with the end-cup system. CR-39 was used as the detector material in combination with a one-step chemical etching procedure and an automatic digital- image counting system. Wherever a high level was measured, a confirming measurement was made using a dynamic method. The results are important for future health studies, including the eventual establishment of patterns for indoor radon concentration, as it has been done in the USA and Europe.

  20. Assessing future trends in indoor air quality

    International Nuclear Information System (INIS)

    van de Wiel, H.J.; Lebret, E.; van der Lingen, W.K.; Eerens, H.C.; Vaas, L.H.; Leupen, M.J.

    1990-01-01

    Several national and international health organizations have derived concentration levels below which adverse effects on men are not expected or levels below which the excess risk for individuals is less than a specified value. For every priority pollutant indoor concentrations below this limit are considered healthy. The percentage of Dutch homes exceeding such a limit is taken as a measure of indoor air quality for that component. The present and future indoor air quality of the Dutch housing stock is described for fourteen air pollutants. The highest percentages are scored by radon, environmental tobacco smoke, nitrogen dioxide from unvented combustion, and the potential presence of housedust mite and mould allergen in damp houses. Although the trend for all priority pollutants is downward the most serious ones remain high in the coming decades if no additional measures will be instituted