WorldWideScience

Sample records for indocyanine green-mediated photothrombosis

  1. Direct Measurement of Free Radical Levels in the Brain After Cortical Ischemia Induced by Photothrombosis

    Czech Academy of Sciences Publication Activity Database

    Mareš, J.; Nohejlová, K.; Stopka, Pavel; Rokyta, R.

    2016-01-01

    Roč. 65, č. 5 (2016), s. 853-860 ISSN 0862-8408 Institutional support: RVO:61388980 Keywords : Free radicals * EPR * Focal ischemia * Brain * Photothrombosis Subject RIV: CA - Inorganic Chemistry Impact factor: 1.461, year: 2016

  2. In vivo imaging of stepwise vessel occlusion in cerebral photothrombosis of mice by 19F MRI.

    Directory of Open Access Journals (Sweden)

    Gesa Weise

    Full Text Available (19F magnetic resonance imaging (MRI was recently introduced as a promising technique for in vivo cell tracking. In the present study we compared (19F MRI with iron-enhanced MRI in mice with photothrombosis (PT at 7 Tesla. PT represents a model of focal cerebral ischemia exhibiting acute vessel occlusion and delayed neuroinflammation.Perfluorocarbons (PFC or superparamagnetic iron oxide particles (SPIO were injected intravenously at different time points after photothrombotic infarction. While administration of PFC directly after PT induction led to a strong (19F signal throughout the entire lesion, two hours delayed application resulted in a rim-like (19F signal at the outer edge of the lesion. These findings closely resembled the distribution of signal loss on T2-weighted MRI seen after SPIO injection reflecting intravascular accumulation of iron particles trapped in vessel thrombi as confirmed histologically. By sequential administration of two chemically shifted PFC compounds 0 and 2 hours after illumination the different spatial distribution of the (19F markers (infarct core/rim could be visualized in the same animal. When PFC were applied at day 6 the fluorine marker was only detected after long acquisition times ex vivo. SPIO-enhanced MRI showed slight signal loss in vivo which was much more prominent ex vivo indicative for neuroinflammation at this late lesion stage.Our study shows that vessel occlusion can be followed in vivo by (19F and SPIO-enhanced high-field MRI while in vivo imaging of neuroinflammation remains challenging. The timing of contrast agent application was the major determinant of the underlying processes depicted by both imaging techniques. Importantly, sequential application of different PFC compounds allowed depiction of ongoing vessel occlusion from the core to the margin of the ischemic lesions in a single MRI measurement.

  3. Dynamic indocyanine green angiography measurements

    Science.gov (United States)

    Holmes, Timothy; Invernizzi, Alessandro; Larkin, Sean; Staurenghi, Giovanni

    2012-11-01

    Dynamic indocyanine green imaging uses a scanning laser ophthalmoscope and a fluorescent dye to produce movies of the dye-filling pattern in the retina and choroid of the eye. It is used for evaluating choroidal neovascularization. Movies are examined to identify the anatomy of the pathology for planning treatment and to evaluate progression or response to treatment. The popularity of this approach is affected by the complexity and difficulty in interpreting the movies. Software algorithms were developed to produce images from the movies that are easy to interpret. A mathematical model is formulated of the flow dynamics, and a fitting algorithm is designed that solves for the flow parameters. The images provide information about flow and perfusion, including regions of change between examinations. Imaged measures include the dye fill-time, temporal dispersion, and magnitude of the dye dilution temporal curves associated with image pixels. Cases show how the software can help to identify clinically relevant anatomy such as feeder vessels, drain vessels, capillary networks, and normal choroidal draining vessels. As a potential tool for research into the character of neovascular conditions and treatments, it reveals the flow dynamics and character of the lesion. Future varieties of this methodology may be used for evaluating the success of engineered tissue transplants, surgical flaps, reconstructive surgery, breast surgery, and many other surgical applications where flow, perfusion, and vascularity of tissue are important.

  4. Photothrombosis-induced infarction of the mouse cerebral cortex is not affected by the Nrf2-activator sulforaphane.

    Directory of Open Access Journals (Sweden)

    Michelle J Porritt

    Full Text Available Sulforaphane-induced activation of the transcription factor NF-E2 related factor 2 (Nrf2 or the gene Nfe2l2 and subsequent induction of the phase II antioxidant system has previously been shown to exert neuroprotective action in a transient model of focal cerebral ischemia. However, its ability to attenuate functional and cellular deficits after permanent focal cerebral ischemia is not clear. We assessed the neuroprotective effects of sulforaphane in the photothrombotic model of permanent focal cerebral ischemia. Sulforaphane was administered (5 or 50 mg/kg, i.p. after ischemic onset either as a single dose or as daily doses for 3 days. Sulforaphane increased transcription of Nrf2, Hmox1, GCLC and GSTA4 mRNA in the brain confirming activation of the Nrf2 system. Single or repeated administration of sulforaphane had no effect on the infarct volume, nor did it reduce the number of activated glial cells or proliferating cells when analyzed 24 and 72 h after stroke. Motor-function as assessed by beam-walking, cylinder-test, and adhesive test, did not improve after sulforaphane treatment. The results show that sulforaphane treatment initiated after photothrombosis-induced permanent cerebral ischemia does not interfere with key cellular mechanisms underlying tissue damage.

  5. Photothrombosis-induced infarction of the mouse cerebral cortex is not affected by the Nrf2-activator sulforaphane.

    Science.gov (United States)

    Porritt, Michelle J; Andersson, Helene C; Hou, Linda; Nilsson, Åsa; Pekna, Marcela; Pekny, Milos; Nilsson, Michael

    2012-01-01

    Sulforaphane-induced activation of the transcription factor NF-E2 related factor 2 (Nrf2 or the gene Nfe2l2) and subsequent induction of the phase II antioxidant system has previously been shown to exert neuroprotective action in a transient model of focal cerebral ischemia. However, its ability to attenuate functional and cellular deficits after permanent focal cerebral ischemia is not clear. We assessed the neuroprotective effects of sulforaphane in the photothrombotic model of permanent focal cerebral ischemia. Sulforaphane was administered (5 or 50 mg/kg, i.p.) after ischemic onset either as a single dose or as daily doses for 3 days. Sulforaphane increased transcription of Nrf2, Hmox1, GCLC and GSTA4 mRNA in the brain confirming activation of the Nrf2 system. Single or repeated administration of sulforaphane had no effect on the infarct volume, nor did it reduce the number of activated glial cells or proliferating cells when analyzed 24 and 72 h after stroke. Motor-function as assessed by beam-walking, cylinder-test, and adhesive test, did not improve after sulforaphane treatment. The results show that sulforaphane treatment initiated after photothrombosis-induced permanent cerebral ischemia does not interfere with key cellular mechanisms underlying tissue damage.

  6. Purinergic receptor stimulation reduces cytotoxic edema and brain infarcts in mouse induced by photothrombosis by energizing glial mitochondria.

    Directory of Open Access Journals (Sweden)

    Wei Zheng

    2010-12-01

    Full Text Available Treatments to improve the neurological outcome of edema and cerebral ischemic stroke are severely limited. Here, we present the first in vivo single cell images of cortical mouse astrocytes documenting the impact of single vessel photothrombosis on cytotoxic edema and cerebral infarcts. The volume of astrocytes expressing green fluorescent protein (GFP increased by over 600% within 3 hours of ischemia. The subsequent growth of cerebral infarcts was easily followed as the loss of GFP fluorescence as astrocytes lysed. Cytotoxic edema and the magnitude of ischemic lesions were significantly reduced by treatment with the purinergic ligand 2-methylthioladenosine 5' diphosphate (2-MeSADP, an agonist with high specificity for the purinergic receptor type 1 isoform (P2Y(1R. At 24 hours, cytotoxic edema in astrocytes was still apparent at the penumbra and preceded the cell lysis that defined the infarct. Delayed 2MeSADP treatment, 24 hours after the initial thrombosis, also significantly reduced cytotoxic edema and the continued growth of the brain infarction. Pharmacological and genetic evidence are presented indicating that 2MeSADP protection is mediated by enhanced astrocyte mitochondrial metabolism via increased inositol trisphosphate (IP(3-dependent Ca(2+ release. We suggest that mitochondria play a critical role in astrocyte energy metabolism in the penumbra of ischemic lesions, where low ATP levels are widely accepted to be responsible for cytotoxic edema. Enhancement of this energy source could have similar protective benefits for a wide range of brain injuries.

  7. Labeling of indocyanine green with carrier-free iodine-123

    International Nuclear Information System (INIS)

    Ansari, A.N.; Lambrecht, R.M.; Redvanly, C.S.; Wolf, A.P.

    1976-01-01

    The method is described for labeling indocyanine green (ICG) with carrier-free iodine-123 by condensing xenon-123 on crystals of ICG followed by permitting decay of the 123 Xe a sufficient length of time to produce 123 I-electronically excited ions and atoms which subsequently label ICG. 4 claims, no drawings

  8. A Review of Indocyanine Green Fluorescent Imaging in Surgery

    Directory of Open Access Journals (Sweden)

    Jarmo T. Alander

    2012-01-01

    Full Text Available The purpose of this paper is to give an overview of the recent surgical intraoperational applications of indocyanine green fluorescence imaging methods, the basics of the technology, and instrumentation used. Well over 200 papers describing this technique in clinical setting are reviewed. In addition to the surgical applications, other recent medical applications of ICG are briefly examined.

  9. Indocyanine green for intraoperative localization of ureter.

    Science.gov (United States)

    Siddighi, Sam; Yune, Junchan Joshua; Hardesty, Jeffrey

    2014-10-01

    Intraurethral injection of indocyanine green (ICG; Akorn, Lake Forest, IL) and visualization under near-infrared (NIR) light allows for real-time delineation of the ureter. This technology can be helpful to prevent iatrogenic ureteral injury during pelvic surgery. Patients were scheduled to undergo robot-assisted laparoscopic sacrocolpopexy. Before the robotic surgery started, the tip of a 6-F ureteral catheter was inserted into the ureteral orifice. Twenty-five milligrams of ICG was dissolved in 10-mL of sterile water and injected through the open catheter. The same procedure was repeated on the opposite side. The ICG reversibly stained the inside lining of the ureter by binding to proteins on urothelial layer. During the course of robotic surgery, the NIR laser on the da Vinci Si surgical robot (Intuitive Surgical, Inc, Sunnyvale, CA) was used to excite ICG molecules, and infrared emission was captured by the da Vinci filtered lens system and electronically converted to green color. Thus, the ureter fluoresced green, which allowed its definitive identification throughout the entire case. In all cases of >10 patients, we were able to visualize bilateral ureters with this technology, even though there was some variation in brightness that depended on the depth of the ureter from the peritoneal surface. For example, in a morbidly obese patient, the ureters were not as bright green. There were no intraoperative or postoperative adverse effects attributable to ICG administration for up to 2 months of observation. In our experience, this novel method of intraurethral ICG injection was helpful to identify the entire course of ureter and allowed a safe approach to tissues that were adjacent to the urinary tract. The advantage of our technique is that it requires the insertion of just the tip of ureteral catheter. Despite our limited cohort of patients, our findings are consistent with previous reports of the excellent safety profile of intravenous and intrabiliary ICG

  10. Indocyanine Green Videoangiography in Negative: Spinal Dural Arteriovenous Fistula.

    Science.gov (United States)

    Simal Julián, Juan Antonio; Miranda Lloret, Pablo; Sanromán Álvarez, Pablo; Pérez de San Román, Laila; Beltrán Giner, Andrés; Botella Asunción, Carlos

    2015-08-01

    Introduction This work reports the first indocyanine green videoangiography (IGV) in negative published with video format support. This technique, so called because its first phase is performed with occlusion of the vessel suspected of being pathologic, is used for the diagnosis of spinal arteriovenous fistula (sDAVF). Case Report The authors present the case of a 68-year-old man with an sDAVF fed by the right T7 segmentary artery. IGV was initially performed with the presumptive fistula feeder occluded for less than 1 minute, which provided both diagnostic and postexclusion control in one procedure. This technique therefore is reversible by not prolonging vascular exclusion times. Discussion IGV in negative is an extremely visual and intuitive procedure that represents an improvement over conventional IGV. Conclusion Studies with larger sample sizes are necessary to determine whether IGV in negative can further reduce the need for postoperative digital subtraction angiography.

  11. Solvent effect on indocyanine dyes: A computational approach

    International Nuclear Information System (INIS)

    Bertolino, Chiara A.; Ferrari, Anna M.; Barolo, Claudia; Viscardi, Guido; Caputo, Giuseppe; Coluccia, Salvatore

    2006-01-01

    The solvatochromic behaviour of a series of indocyanine dyes (Dyes I-VIII) was investigated by quantum chemical calculations. The effect of the polymethine chain length and of the indolenine structure has been satisfactorily reproduced by semiempirical Pariser-Parr-Pople (PPP) calculations. The solvatochromism of 3,3,3',3'-tetramethyl-N,N'-diethylindocarbocyanine iodide (Dye I) has been deeply investigated within the ab initio time-dependent density functional theory (TD-DFT) approach. Dye I undergoes non-polar solvation and a linear correlation has been individuated between absorption shifts and refractive index. Computed absorption λ max and oscillator strengths obtained by TD-DFT are in good agreement with the experimental data

  12. [Indocyanine green angiography in "multiple evanescent white dot syndrome" (MEWDS)].

    Science.gov (United States)

    Desarnaulds, A B; Borruat, F X; Herbort, C P; de Courten, C

    1998-05-01

    Multiple evanescent white dot syndrome (MEWDS) is a benign acquired chorioretinal disorder occurring mostly in young adults. Its pathophysiology is unknown. To describe the results of indocyanine green angiography (ICGA) in MEWDS. Four patients with MEWDS were investigated by ICGA. In all cases, ICGA revealed numerous choroidal hypofluorescent lesions that largely outnumbered the lesions visible with either fundoscopy or fluorescein angiography. Three cases showed a blind spot enlargement on perimetry associated with the presence of a large peripapillary hypofluorescent zone on ICGA. Three cases showed macular granularity on fundoscopy correlating with a significant subfoveal hypfluorescent lesion on ICGA. Evolution was always favorable with disappearance of the hypofluorescent choroidal lesions. Our results confirm that MEWDS is primarily a choroidal disorder. The blind spot enlargement and the macular granularity, frequently detected in MEWDS, result from larger peripapillary and subfoveal choroidal lesions.

  13. Indocyanine green staining facilitates detection of bleb leakage during trabeculectomy.

    Science.gov (United States)

    Okazaki, Teruhiko; Kiuchi, Takahiro; Kawana, Keisuke; Oshika, Tetsuro

    2007-03-01

    To report a new technique to visualize bleb leakage using indocyanine green (ICG) staining during trabeculectomy. The ICG solution was widely applied over the filtering bleb including the conjunctival wound before completion of trabeculectomy. This procedure was performed in 48 eyes of 44 consecutive patients undergoing trabeculectomy between December 2004 and October 2005. Without staining, bleb leakage was not identified by the direct observation under the operating microscope. ICG staining clearly visualized aqueous leakage from the bleb in 5 eyes (10.4%). The bleb leakage in these eyes was easily repaired with 10-0 nylon sutures, and no eyes, including these 5 cases, showed bleb leakage after surgery. There were no intraoperative and postoperative complications related to ICG application. The application of ICG during trabeculectomy is a simple and useful technique to facilitate detection and repair of the bleb leakage.

  14. Application of Indocyanine Green in Flap Surgery: A Systematic Review.

    Science.gov (United States)

    Li, Ke; Zhang, Zheng; Nicoli, Fabio; D'Ambrosia, Christopher; Xi, Wenjing; Lazzeri, Davide; Feng, Shaoqing; Su, Weijie; Li, Hua; Ciudad, Pedro; Tremp, Mathias; Zhang, Yi Xin

    2018-02-01

     The vascularization of the distal portions of transferred tissue represents the most critical factor in the success of reconstructive surgery. In recent years, indocyanine green (ICG) fluorescence imaging techniques have been applied during surgery to evaluate flap perfusion. However, this investigation has found that there is little consensus regarding the standard dose of ICG as well as the pre-operative requirements of ICG allergy testing. The aim of this study is to summarize the applications of ICG to tissue transfers and safe dosing practices and to provide insight to the possible adverse effects of ICG on flap surgery with the goal of helping clinicians apply ICG safely and efficiently to tissue transfer procedures.  A literature search was performed using, Wiley InterScience, and Springer with the key words, 'Flap,' 'indocyanine green,' 'surgery,' and related mesh words for all publications between 2005 and 2015. Title and abstract screening was performed using predefined in- and exclusion criteria.  Seventy-three articles were included. These were classified as "application of ICG in flap surgery" and "the security of applying ICG in flap surgery".  ICG fluorescence imaging preoperatively facilitates the detection of perforators in tissue flaps with thickness <20 mm, aids in the evaluation of flap microcirculation and perfusion, and allows surgeons to select dominant cutaneous nerves while evaluating the quality of vascular anastomoses and locating thromboses. The literature also concluded that potential allergic reactions to ICG should be taken into consideration. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Photoacoustic tomography of human hepatic malignancies using intraoperative indocyanine green fluorescence imaging.

    Science.gov (United States)

    Miyata, Akinori; Ishizawa, Takeaki; Kamiya, Mako; Shimizu, Atsushi; Kaneko, Junichi; Ijichi, Hideaki; Shibahara, Junji; Fukayama, Masashi; Midorikawa, Yutaka; Urano, Yasuteru; Kokudo, Norihiro

    2014-01-01

    Recently, fluorescence imaging following the preoperative intravenous injection of indocyanine green has been used in clinical settings to identify hepatic malignancies during surgery. The aim of this study was to evaluate the ability of photoacoustic tomography using indocyanine green as a contrast agent to produce representative fluorescence images of hepatic tumors by visualizing the spatial distribution of indocyanine green on ultrasonographic images. Indocyanine green (0.5 mg/kg, intravenous) was preoperatively administered to 9 patients undergoing hepatectomy. Intraoperatively, photoacoustic tomography was performed on the surface of the resected hepatic specimens (n = 10) under excitation with an 800 nm pulse laser. In 4 hepatocellular carcinoma nodules, photoacoustic imaging identified indocyanine green accumulation in the cancerous tissue. In contrast, in one hepatocellular carcinoma nodule and five adenocarcinoma foci (one intrahepatic cholangiocarcinoma and 4 colorectal liver metastases), photoacoustic imaging delineated indocyanine green accumulation not in the cancerous tissue but rather in the peri-cancerous hepatic parenchyma. Although photoacoustic tomography enabled to visualize spatial distribution of ICG on ultrasonographic images, which was consistent with fluorescence images on cut surfaces of the resected specimens, photoacoustic signals of ICG-containing tissues decreased approximately by 40% even at 4 mm depth from liver surfaces. Photoacoustic tomography using indocyanine green also failed to identify any hepatocellular carcinoma nodules from the body surface of model mice with non-alcoholic steatohepatitis. In conclusion, photoacoustic tomography has a potential to enhance cancer detectability and differential diagnosis by ultrasonographic examinations and intraoperative fluorescence imaging through visualization of stasis of bile-excreting imaging agents in and/or around hepatic tumors. However, further technical advances are needed

  16. Photoacoustic tomography of human hepatic malignancies using intraoperative indocyanine green fluorescence imaging.

    Directory of Open Access Journals (Sweden)

    Akinori Miyata

    Full Text Available Recently, fluorescence imaging following the preoperative intravenous injection of indocyanine green has been used in clinical settings to identify hepatic malignancies during surgery. The aim of this study was to evaluate the ability of photoacoustic tomography using indocyanine green as a contrast agent to produce representative fluorescence images of hepatic tumors by visualizing the spatial distribution of indocyanine green on ultrasonographic images. Indocyanine green (0.5 mg/kg, intravenous was preoperatively administered to 9 patients undergoing hepatectomy. Intraoperatively, photoacoustic tomography was performed on the surface of the resected hepatic specimens (n = 10 under excitation with an 800 nm pulse laser. In 4 hepatocellular carcinoma nodules, photoacoustic imaging identified indocyanine green accumulation in the cancerous tissue. In contrast, in one hepatocellular carcinoma nodule and five adenocarcinoma foci (one intrahepatic cholangiocarcinoma and 4 colorectal liver metastases, photoacoustic imaging delineated indocyanine green accumulation not in the cancerous tissue but rather in the peri-cancerous hepatic parenchyma. Although photoacoustic tomography enabled to visualize spatial distribution of ICG on ultrasonographic images, which was consistent with fluorescence images on cut surfaces of the resected specimens, photoacoustic signals of ICG-containing tissues decreased approximately by 40% even at 4 mm depth from liver surfaces. Photoacoustic tomography using indocyanine green also failed to identify any hepatocellular carcinoma nodules from the body surface of model mice with non-alcoholic steatohepatitis. In conclusion, photoacoustic tomography has a potential to enhance cancer detectability and differential diagnosis by ultrasonographic examinations and intraoperative fluorescence imaging through visualization of stasis of bile-excreting imaging agents in and/or around hepatic tumors. However, further technical

  17. Development of ultrasound-assisted fluorescence imaging of indocyanine green.

    Science.gov (United States)

    Morikawa, Hiroyasu; Toyota, Shin; Wada, Kenji; Uchida-Kobayashi, Sawako; Kawada, Norifumi; Horinaka, Hiromichi

    2017-01-01

    Indocyanine green (ICG) accumulation in hepatocellular carcinoma means tumors can be located by fluorescence. However, because of light scattering, it is difficult to detect ICG fluorescence from outside the body. We propose a new fluorescence imaging method that detects changes in the intensity of ICG fluorescence by ultrasound-induced temperature changes. ICG fluorescence intensity decreases as the temperature rises. Therefore, it should theoretically be possible to detect tissue distribution of ICG using ultrasound to heat tissue, moving the point of ultrasound transmission, and monitoring changes in fluorescence intensity. A new probe was adapted for clinical application. It consisted of excitation light from a laser, fluorescence sensing through a light pipe, and heating by ultrasound. We applied the probe to bovine liver to image the accumulation of ICG. ICG emits fluorescence (820 nm) upon light irradiation (783 nm). With a rise in temperature, the fluorescence intensity of ICG decreased by 0.85 %/°C. The distribution of fluorescent ICG was detected using an ultrasonic warming method in a new integrated probe. Modulating fluorescence by changing the temperature using ultrasound can determine where ICG accumulates at a depth, highlighting its potential as a means to locate hepatocellular carcinoma.

  18. Multiphoton photodegradation of indocyanine green: Solvent protolysis effect

    Energy Technology Data Exchange (ETDEWEB)

    Fuyuki, Masanori, E-mail: mn.fuyuki@kio.ac.jp

    2016-02-15

    The multiphoton photodegradation mechanism of indocyanine green (ICG) was investigated by using femtosecond near-infrared (NIR) pump and probe pulses. In the pump fluence region from 2 mJ/cm{sup 2} to 4 mJ/cm{sup 2}, the photodegradation rate was higher in acetic acid than in ethanol, and the rate was proportional to pump fluence to the 2.3th power in acetic acid and the 3.9th in ethanol. Considering that the degree of auto-protolysis of acetic acid is much higher than that of ethanol, the experimental results indicate that self-ionized solvent molecules played an essential role in the degradation of ICG molecules excited by NIR multiphoton process. - Highlights: • Photodegradation of ICG by femtosecond near-infrared pulses. • Photodegradation rate of ICG was higher in acetic acid than in ethanol. • Photodegradation rate was proportional to pump fluence to 2.3th power in acetic acid. • Photodegradation rate was proportional to pump fluence to 3.9th power in ethanol. • Self-ionized solvent molecules promoted ICG photodegradation in acetic acid.

  19. Liver volume, portal vein flow, and clearance of indocyanine green and antipyrine in hyperthyroidism before and after antithyroid treatment

    DEFF Research Database (Denmark)

    Andersen, Vibeke; Sonne, J; Court-Payen, M

    1999-01-01

    The aim of the study was to examine liver volume, portal vein flow, and indocyanine green (ICG) and antipyrine clearance in hyperthyroidism before and after antithyroid drug treatment.......The aim of the study was to examine liver volume, portal vein flow, and indocyanine green (ICG) and antipyrine clearance in hyperthyroidism before and after antithyroid drug treatment....

  20. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    Germans, Menno R.; de Witt Hamer, Philip C.; van Boven, Leonard J.; Zwinderman, Koos A. H.; Bouma, Gerrit J.

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  1. Antipyrine, oxazepam, and indocyanine green clearance in patients with chronic pancreatitis and healthy subjects

    DEFF Research Database (Denmark)

    Andersen, Vibeke; Sonne, J; Larsen, S

    1999-01-01

    Hepatic drug metabolism was examined in patients with chronic pancreatitis and healthy controls by using a cocktail design with three different model compounds: antipyrine to express phase-I oxidation, oxazepam to express phase-II conjugation, and indocyanine green (ICG), a high-clearance compound....

  2. Hepatectomy Based on Future Liver Remnant Plasma Clearance Rate of Indocyanine Green

    Directory of Open Access Journals (Sweden)

    Yuichiro Uchida

    2016-01-01

    Full Text Available Background. Hepatectomy, an important treatment modality for liver malignancies, has high perioperative morbidity and mortality rates. Safe, comprehensive criteria for selecting patients for hepatectomy are needed. Since June 2011, we have used a cut-off value of ≧ 0.05 for future liver remnant plasma clearance rate of indocyanine green as a criterion for hepatectomy. The aim of this study was to verify the validity of this criterion. Methods. From June 2011 to December 2015, 212 hepatectomies were performed in Tenri Yorozu Hospital. Of these 212 patients, 107 who underwent preoperative computed tomography imaging volumetry, indocyanine green clearance test, and hepatectomy (excluding partial resection or enucleation were retrospectively analyzed. Results. There was no postoperative mortality. Posthepatectomy liver failure occurred in 59 patients (55.1% (International Study Group of Liver Surgery Grade A: 43 cases (40.2%, Grade B: 16 cases (15.0%, and Grade C: no cases. Operative morbidity greater than Clavien-Dindo Grade 3 occurred in 23 patients (21.5%. A low future liver remnant plasma clearance rate of indocyanine green was a good predictor for Grade B cases (area under curve = 0.804; 95% confidence interval, 0.712–0.895. Conclusion. Liver remnant plasma clearance rate of indocyanine green is a valid criterion for hepatectomy.

  3. Impact of the time window on plasma volume measurement with indocyanine green

    International Nuclear Information System (INIS)

    Jacob, M; Chappell, D; Conzen, P; Finsterer, U; Rehm, M; Krafft, A; Becker, B F

    2008-01-01

    Recent reports have questioned the accuracy of the indocyanine green dilution technique for measuring plasma volume. Our objective was to evaluate the impact of different time windows for monoexponential extrapolation. We retrospectively analysed 31 indocyanine green decay curves to investigate the problem in principle (group 1) and prospectively performed another 21 plasma volume measurements to estimate its practical impact (group 2). To monoexponentially extrapolate back to the specific extinction at the time of dye injection, two different time windows were applied to each decay curve, comparing the plasma volumes resulting from sampling within a short (≤5 min) versus a longer (>5 min) period of time. Extrapolating back from the longer period led to a higher apparent plasma volume relative to the shorter period in both groups, the difference being 348 ± 171 ml (group 1) and 384 ± 131 ml (group 2; mean ± SD; p < 0.05 each). This result was due to a reliable monoexponentiality of decay only up to the 5th min after dye injection. Thus, to estimate the initial distribution space of indocyanine green via monoexponential extrapolation, the first linear kinetic of indocyanine green decay should be taken

  4. Microencapsulation of indocyanine green for potential applications in image-guided drug delivery.

    Science.gov (United States)

    Zhu, Zhiqiang; Si, Ting; Xu, Ronald X

    2015-02-07

    We present a novel process to encapsulate indocyanine green (ICG) in liposomal droplets at high concentration for potential applications in image-guided drug delivery. The microencapsulation process follows two consecutive steps of droplet formation by liquid-driven coaxial flow focusing (LDCFF) and solvent removal by oil phase dewetting. These biocompatible lipid vesicles may have important applications in drug delivery and fluorescence imaging.

  5. Lethal photosensitization of wound-associated microbes using indocyanine green and near-infrared light

    DEFF Research Database (Denmark)

    Omar, Ghada Said Mohammed; Wilson, Michael; Nair, Sean P.

    2008-01-01

    Background: The increase in resistance to antibiotics among disease-causing bacteria necessitates the development of alternative antimicrobial approaches such as the use of light-activated antimicrobial agents (LAAAs). Light of an appropriate wavelength activates the LAAA to produce cytotoxic...... of the bacteria. Conclusion: These findings imply that indocyanine green in combination with light from a nearinfrared laser may be an effective means of eradicating bacteria from wounds and burns....

  6. Gastric Tube Reconstruction with Superdrainage Using Indocyanine Green Fluorescence During Esophagectomy

    OpenAIRE

    KITAGAWA, HIROYUKI; NAMIKAWA, TSUTOMU; IWABU, JUN; HANAZAKI, KAZUHIRO

    2017-01-01

    We report a case of gastric tube reconstruction with superdrainage using indocyanine green fluorescence during esophagectomy for esophageal cancer. A 53-year-old man with a history of early esophageal cancer treated with endoscopic mucosal dissection experienced esophageal cancer recurrence. There was no evidence of lymph node involvement or distant metastasis on computed tomography; therefore, we performed thoracoscopic esophagectomy. After thoracoscopic esophagectomy, we created a gastric t...

  7. Comparison of indocyanine green clearance with Child's-Pugh score and hepatic histology: a multivariate analysis.

    Science.gov (United States)

    Mukherjee, Sandeep; Rogers, Mary A M; Buniak, Borys

    2006-01-01

    Indocyanine green clearance, measured by percentage disappearance rate, detects alterations in liver function and may be used as a non-invasive determinant of hepatic reserve. The aims of this study were to compare liver histology and Child's-Pugh score with percentage disappearance rate and determine which variables correlated with PDR. Child's-Pugh score, liver function tests, liver biopsies and indocyanine green testing (0.5mg/kg) were performed in 102 consecutive patients with cirrhosis of diverse etiologies. Indocyanine green concentration was determined using spectrophotometric analysis (806nm) and plotted logarithmically with Michaelis-Menten kinetics to calculate the percentage disappearance rate. Liver biopsies were graded using the modified Knodell score to obtain a histological activity index. In bivariable analysis, percentage disappearance rate significantly correlated with Child's-Pugh score, albumin, bilirubin, prothrombin time and histological activity index. Albumin, prothrombin time and histological activity index were independent predictors of percentage disappearance rate in the final model (albumin ptime ptime and histological activity index.

  8. Comparison of measurements of plasma clearance of Mebrofenine and of indocyanine green

    International Nuclear Information System (INIS)

    Maurel, G.; Coutris, G.; Vaubourdolle, M.; Attal, P.; Patureau, R.; Tabsoba, Th.; Mensch, B.; Askienazy, Pr.S.

    1997-01-01

    The importance of clearance measurements in evaluating renal or hepatic function needs not further demonstration. The isotopic methods were proved in renal exploration but their utilization in exploration of hepato-biliary function needs to be evaluated. In this work we have compared the measurement of plasma clearance by Mebrofenine, a radiopharmaceutical of specifically hepatic elimination, with the reference method, the clearance of indocyanine green. On the basis of scintigraphic data from 23 patients who benefited by a hepato-biliary exploration by Mebrofenine- 99m Tc for pre-surgery account and surveillance, we have determined the plasma clearance of this radiopharmaceutical. The method makes use of the curve of normalized cardiac activity by a blood sampling, taken 60 minutes after injection. The measurement of the clearance of indocyanine green was effected within a delay inferior to 1 month from the moment of biliary scintigraphy. The average clearance of Mebrofenine- 99m Tc is of 553 ml/min for 1.73 m 2 of corporal surface (typical interval is 374 ml/min), the value of indocyanine green is of 450 ml/min (typical interval is 229 ml/min). The two measurements of clearance are correlated (p = 0.05). In conclusion, the measurement of clearance by Mebrofenine- 99m appears to be adapted to the evaluation of hepato-biliary function

  9. Gastric Tube Reconstruction with Superdrainage Using Indocyanine Green Fluorescence During Esophagectomy.

    Science.gov (United States)

    Kitagawa, Hiroyuki; Namikawa, Tsutomu; Iwabu, Jun; Hanazaki, Kazuhiro

    2017-01-01

    We report a case of gastric tube reconstruction with superdrainage using indocyanine green fluorescence during esophagectomy for esophageal cancer. A 53-year-old man with a history of early esophageal cancer treated with endoscopic mucosal dissection experienced esophageal cancer recurrence. There was no evidence of lymph node involvement or distant metastasis on computed tomography; therefore, we performed thoracoscopic esophagectomy. After thoracoscopic esophagectomy, we created a gastric tube. When pulling up the gastric tube through the post-mediastinum route, a root of the right gastroepiploic vein was injured. We subsequently performed superdrainage to avoid congestion of the gastric tube with omental vein and pre-tracheal vein anastomosis at the neck, and confirmed venous flow using the indocyanine green fluorescence method. No postoperative anastomotic leakage was observed, and the patient was discharged 22 days after surgery. Thus, we recommend the indocyanine green fluorescence method in cases involving superdrainage during esophagectomy. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  10. Phototoxic effect of conjugates of plasmon-resonance nanoparticles with indocyanine green dye on Staphylococcus aureus induced by IR laser radiation

    International Nuclear Information System (INIS)

    Tuchina, E S; Tuchin, Valerii V; Khlebtsov, B N; Khlebtsov, Nikolai G

    2011-01-01

    The effect of IR laser radiation (λ = 805 - 808 nm) on the bacteria of the strain Staphylococcus aureus 209 P, incubated in indocyanine green solutions, is studied, as well as that of colloid gold nanoshells, nanocages and their conjugates with indocyanine green. It is found that the S. aureus 209 P cells are equally subjected to the IR laser radiation (λ = 805 nm) after preliminary sensitisation with indocyanine green and gold nanoparticles separately and with conjugates of nanoparticles and indocyanine green. The enhancement of photodynamic and photothermal effects by 5 % is observed after 30 min of laser illumination (λ = 808 nm) of bacteria, treated with conjugates of indocyanine green and nanocages. (optical technologies in biophysics and medicine)

  11. Retinal pigment epithelial atrophy following indocyanine green dye-assisted surgery for serous macular detachment

    Directory of Open Access Journals (Sweden)

    Hussain Nazimul

    2008-01-01

    Full Text Available To report subretinal migration of indocyanine green dye (ICG and subsequent retinal pigment epithelial (RPE atrophy during macular surgery for serous macular detachment. A 65-year-old woman presented with residual epiretinal membrane and serous detachment of the macula following vitreoretinal surgery for epiretinal membrane. She underwent resurgery with ICG-assisted internal limiting membrane peeling and intraocular tamponade. Intraoperatively a large area of subretinal ICG was seen with subsequent RPE mottling and atrophy of the macula in the area involved during follow-up. This case demonstrates that subretinal migration of ICG is possible and can be toxic to RPE.

  12. Indocyanine green fluorescence angiography for intraoperative assessment of gastrointestinal anastomotic perfusion

    DEFF Research Database (Denmark)

    Degett, Thea Helene; Andersen, Helene Schou; Gögenur, Ismail

    2016-01-01

    PURPOSE: Anastomotic leakage following gastrointestinal surgery remains a frequent and serious complication associated with a high morbidity and mortality. Indocyanine green fluorescence angiography (ICG-FA) is a newly developed technique to measure perfusion intraoperatively. The aim of this paper...... included in the review if they assessed anastomotic perfusion intraoperatively with ICG-FA in order to predict anastomotic leakage in humans. RESULTS: Of 790 screened papers 14 studies were included in this review. Ten studies (n = 916) involved patients with colorectal anastomoses and four studies (n...

  13. Lethal photosensitization of wound-associated microbes using indocyanine green and near-infrared light

    Directory of Open Access Journals (Sweden)

    Wilson Michael

    2008-07-01

    Full Text Available Abstract Background The increase in resistance to antibiotics among disease-causing bacteria necessitates the development of alternative antimicrobial approaches such as the use of light-activated antimicrobial agents (LAAAs. Light of an appropriate wavelength activates the LAAA to produce cytotoxic species which can then cause bacterial cell death via loss of membrane integrity, lipid peroxidation, the inactivation of essential enzymes, and/or exertion of mutagenic effects due to DNA modification. In this study, the effect of the LAAA indocyanine green excited with high or low intensity light (808 nm from a near-infrared laser (NIR on the viability of Staphylococcus aureus, Streptococcus pyogenes and Pseudomonas aeruginosa was investigated. Results All species were susceptible to killing by the LAAA, the bactericidal effect being dependent on both the concentration of indocyanine green and the light dose. Indocyanine green photosensitization using both high (1.37 W cm-2 and low (0.048 W cm-2 intensity NIR laser light was able to achieve reductions of 5.6 log10 (>99.99% and 6.8 log10 (>99.99% in the viable counts of Staph. aureus and Strep. pyogenes (using starting concentrations of 106–107 CFU ml-1. Kills of 99.99% were obtained for P. aeruginosa (initial concentration 108–109 CFU ml-1 photosensitized by the high intensity light (1.37 W cm-2; while a kill of 80% was achieved using low intensity irradiation (0.07 W cm-2. The effects of L-tryptophan (a singlet oxygen scavenger and deuterium oxide (as an enhancer of the life span of singlet oxygen on the survival of Staph. aureus was also studied. L-tryptophan reduced the proportion of Staph. aureus killed; whereas deuterium oxide increased the proportion killed suggesting that singlet oxygen was involved in the killing of the bacteria. Conclusion These findings imply that indocyanine green in combination with light from a near-infrared laser may be an effective means of eradicating bacteria

  14. The Role of Indocyanine Green for Robotic Partial Nephrectomy: Early Results, Limitations and Future Directions

    Directory of Open Access Journals (Sweden)

    Zachary Klaassen

    2014-07-01

    Full Text Available The surgical management of small renal masses has continued to evolve, particularly with the advent of the robotic partial nephrectomy (RPN. Recent studies at high volume institutions utilizing near infrared imaging with indocyanine green (ICG fluorescent dye to delineate renal tumor anatomy has generated interest among robotic surgeons for improving warm ischemia times and positive margin rate for RPN. To date, early studies suggest positive margin rate using ICG is comparable to traditional RPN, however this technology improves visualization of the renal vasculature allowing selective clamping or zero ischemia. The precise combination of fluorescent compound, dose, and optimal tumor anatomy for ICG RPN has yet to be elucidated.

  15. Designing MgFe{sub 2}O{sub 4} decorated on green mediated reduced graphene oxide sheets showing photocatalytic performance and luminescence property

    Energy Technology Data Exchange (ETDEWEB)

    Shetty, Krushitha [Department of Nanotechnology, PG Center, Bangalore Region, VIAT, VTU, Muddenahalli, Chikkaballapur 562101 (India); Dr. D. Premachandrasagar Centre for Advanced Materials, DSCE, Bangalore 560078 (India); Lokesh, S.V. [Department of Nanotechnology, PG Center, Bangalore Region, VIAT, VTU, Muddenahalli, Chikkaballapur 562101 (India); Rangappa, Dinesh, E-mail: dineshrangappa@gmail.com [Department of Nanotechnology, PG Center, Bangalore Region, VIAT, VTU, Muddenahalli, Chikkaballapur 562101 (India); Nagaswarupa, H.P., E-mail: nagaswarupa77@gmail.com [Research Center, Department of Science, East West Institute of Technology, Bangalore 560091 (India); Nagabhushana, H., E-mail: bhushanvlc@gmail.com [Prof. CNR Rao Centre for Advanced Materials, Tumkur University, Tumkur 572103 (India); Anantharaju, K.S., E-mail: iamananthkurupalya@gmail.com [Department of Chemistry, Dayananda Sagar College of Engineering, Shavige Malleshwara Hills, Kumaraswamy Layout, Bangalore 560078 (India); Dr. D. Premachandrasagar Centre for Advanced Materials, DSCE, Bangalore 560078 (India); Prashantha, S.C. [Research Center, Department of Science, East West Institute of Technology, Bangalore 560091 (India); Vidya, Y.S. [Department of Physics, Lal Bahadur Shastri Government First Grade College, Bangalore, 560032 (India); Sharma, S.C. [Dr. D. Premachandrasagar Centre for Advanced Materials, DSCE, Bangalore 560078 (India); Department of Mechanical Engineering, DSCE, Bangalore-560078 (India)

    2017-02-15

    Here, a green route has been reported to convert Graphene Oxide (GO) to reduced graphene oxide (RGO) using clove extract. A modest and eco-accommodating sol-gel strategy has been employed to prepare MgFe{sub 2}O{sub 4} nanoparticles, MgFe{sub 2}O{sub 4}–RGO nanocomposite samples. The samples were analyzed by Powder X-ray diffraction (PXRD), Fourier Transform Infrared Spectroscopy (FTIR), UV–Visible Spectroscopy, Scanning Electron Microcopy (SEM), Transmission Electron Microscopy (TEM), Photoluminescence (PL) and Electrochemical Impedance Spectroscopy (EIS). PXRD result revealed that the prepared samples were cubic spinel in nature. SEM results uncovered flake like surface morphology of the prepared nanomaterial. Better PL emission signature was observed when excited at 329 nm. PL studies demonstrated that the present samples were potential for the fabrication of white component of white light emitting diodes (WLEDs). Further, MgFe{sub 2}O{sub 4}–RGO nanocomposite showed enhanced photocatalytic movement (PCM) and photostability under Sunlight in the decomposition of Malachite Green (MG) compared to MgFe{sub 2}O{sub 4}. This can be attributed to the interaction of MgFe{sub 2}O{sub 4} surface with RGO sheets which results in PL quenching, demonstrates that the recombination of photo-induced electrons and holes in MgFe{sub 2}O{sub 4}–RGO nanocomposite is more effectively inhibited. A possible mechanism for the enhanced properties of MgFe{sub 2}O{sub 4}–RGO nanocomposite was discussed. Moreover, MgFe{sub 2}O{sub 4}–RGO photocatalyst also showed easy magnetic separation with high reusability. These results unveil that the synthesized sample can be used in display applications and also as a potential photocatalyst. - Graphical abstract: Green mediated reduced graphene oxide with MgFe{sub 2}O{sub 4} for display applications and also as a potential photocatalyst. - Highlights: • Synthesized GO was reduced to RGO by green route using clove extract. • Mg

  16. Indocyanine green videoangiography "in negative": definition and usefulness in spinal dural arteriovenous fistulae.

    Science.gov (United States)

    Simal Julián, Juan Antonio; Miranda Lloret, Pablo; López González, Antonio; Evangelista Zamora, Rocío; Botella Asunción, Carlos

    2013-05-01

    Indocyanine green videoangiography (IGV) has proven its effectiveness in the field of exovascular neurosurgery, both in the intracranial and spinal compartment, but is necessary to define a systematic process for the performance of the IGV to facilitate its interpretation during the procedure. We have defined and applied the concept of videoangiography "in negative" (INIGV) to spinal dural arteriovenous fistulae (dAVF) for the detection and treatment of arteriovenous shunts, so called because the first phase is performed with the vessel suggestive of being pathological occluded. A Pentero-operating microscope with near-infrared IGV-integrated system (Carl Zeiss Co., Germany) was used. At our institution, 24 patients were treated for a spinal dAVF between 1995 and 2011, only in the last 4 cases, INIGV was performed. We describe the IGV in negative procedure and show the most illustrative cases. In all cases, the fistula occlusion was confirmed by postoperative selective digital subtraction angiography (DSA). INIGV demonstrate its capacity in detecting vessels not actually arterialized that should be respected and avoid some of the main limitations of the conventional IGV. This is a technical description about an Indocyanine green (ICG) videoangiographic procedure modification that is superior to merely performing ICG before and after clipping of a dAVF. The INIGV results are rapid and easy to interpret procedure and provide great advantages to the dAVF treatment. Nevertheless, further studies are needed with a larger sample size to determine if INIGV may reduce the need to perform immediate postoperative DSA.

  17. Lipid nanoparticle vectorization of indocyanine green improves fluorescence imaging for tumor diagnosis and lymph node resection.

    Science.gov (United States)

    Navarro, Fabrice P; Berger, Michel; Guillermet, Stéphanie; Josserand, Véronique; Guyon, Laurent; Neumann, Emmanuelle; Vinet, Françoise; Texier, Isabelle

    2012-10-01

    Fluorescence imaging is opening a new era in image-guided surgery and other medical applications. The only FDA approved contrast agent in the near infrared is IndoCyanine Green (ICG), which despites its low toxicity, displays poor chemical and optical properties for long-term and sensitive imaging applications in human. Lipid nanoparticles are investigated for improving ICG optical properties and in vivo fluorescence imaging sensitivity. 30 nm diameter lipid nanoparticles (LNP) are loaded with ICG. Their characterization and use for tumor and lymph node imaging are described. Nano-formulation benefits dye optical properties (6 times improved brightness) and chemical stability (>6 months at 4 degrees C in aqueous buffer). More importantly, LNP vectorization allows never reported sensitive and prolonged (>1 day) labeling of tumors and lymph nodes. Composed of human-use approved ingredients, this novel ICG nanometric formulation is foreseen to expand rapidly the field of clinical fluorescence imaging applications.

  18. Application of indocyanine green video angiography in surgical treatment of intracranial aneurysms

    Directory of Open Access Journals (Sweden)

    Felix Hendrik Pahl

    2015-07-01

    Full Text Available Indocyanine green (ICG video angiography has been used for several medical indications in the last decades. It allows a real time evaluation of vascular structures during the surgery. This study describes the surgical results of a senior vascular neurosurgeon. We retrospectively searched our database for all aneurysm cases treated with the aid of intraoperative ICG from 2009 to 2014. A total of 61 aneurysms in 56 patients were surgically clipped using intraoperative ICG. Clip reposition after ICG happened in 2 patients (3.2%. Generally, highly variable clip adjustment rates of 2%–38% following ICG have been reported since the introduction of this imaging technique. The application of ICG in vascular neurosurgery is still an emerging challenge. It is an adjunctive strategy which facilitates aneurismal evaluation and treatment in experienced hands. Nevertheless, a qualified vascular neurosurgeon is still the most important component of a high quality work.

  19. Relevance of intraoperative indocyanine green injection in breast reconstruction using DIEP procedure for abdominal scars.

    Science.gov (United States)

    Louges, M A; Bellaiche, J; Correia, N; Chiriac, S; François, C

    2016-06-01

    The presence of midline sub-umbilical and/or suprapubic scar can sometimes hinder breast reconstruction using deep inferior epigastric perforator (DIEP) procedure. We report the use of indocyanine green injection in a 60-year-old woman in the context of deep inferior epigastric perforator (DIEP) procedure for unilateral breast reconstruction (bilateral breast cancer) with abdominal scar (midline sub-umbilical scar and Pfannenstiel incision scar). This technique underlines the importance of neoangiogenesis mechanisms and helped simplify the surgical gesture initially planned (in order to ensure volume in spite of the scars as a DIEP procedure with double anastomoses was initially planned). This intraoperative vascular imaging technique is a minimally invasive, simple and quick procedure allowing the precise visualization of vascularized territories. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. In Vivo Photoacoustic and Fluorescence Cystography Using Clinically Relevant Dual Modal Indocyanine Green

    Directory of Open Access Journals (Sweden)

    Sungjo Park

    2014-10-01

    Full Text Available Conventional X-ray-based cystography uses radio-opaque materials, but this method uses harmful ionizing radiation and is not sensitive. In this study, we demonstrate nonionizing and noninvasive photoacoustic (PA and fluorescence (FL cystography using clinically relevant indocyanine green (ICG in vivo. After transurethral injection of ICG into rats through a catheter, their bladders were photoacoustically and fluorescently visualized. A deeply positioned bladder below the skin surface (i.e., ~1.5–5 mm was clearly visible in the PA and FL image using a laser pulse energy of less than 2 mJ/cm2 (1/15 of the safety limit. Then, the in vivo imaging results were validated through in situ studies. Our results suggest that dual modal cystography can provide a nonionizing and noninvasive imaging tool for bladder mapping.

  1. Utility of Indocyanine Green Fluorescence Imaging for Intraoperative Localization in Reoperative Parathyroid Surgery.

    Science.gov (United States)

    Sound, Sara; Okoh, Alexis; Yigitbas, Hakan; Yazici, Pinar; Berber, Eren

    2015-10-27

    Due to the variations in anatomic location, the identification of parathyroid glands may be challenging. Although there have been advances in preoperative imaging modalities, there is still a need for an accurate intraoperative guidance. Indocyanine green (ICG) is a new agent that has been used for intraoperative fluorescence imaging in a number of general surgical procedures. Its utility for parathyroid localization in humans has not been reported in the literature. We report 3 patients who underwent reoperative neck surgery for primary hyperparathyroidism. Using a video-assisted technique with intraoperative ICG fluorescence imaging, the parathyroid glands were recognized and removed successfully in all cases. Surrounding soft tissue structures remained nonfluorescent, and could be distinguished from the parathyroid glands. This report suggests a potential utility of ICG imaging in intraoperative localization of parathyroid glands in reoperative neck surgery. Future work is necessary to assess its benefit for first-time parathyroid surgery. © The Author(s) 2015.

  2. Near-infrared-fluorescence imaging of lymph nodes by using liposomally formulated indocyanine green derivatives.

    Science.gov (United States)

    Toyota, Taro; Fujito, Hiromichi; Suganami, Akiko; Ouchi, Tomoki; Ooishi, Aki; Aoki, Akira; Onoue, Kazutaka; Muraki, Yutaka; Madono, Tomoyuki; Fujinami, Masanori; Tamura, Yutaka; Hayashi, Hideki

    2014-01-15

    Liposomally formulated indocyanine green (LP-ICG) has drawn much attention as a highly sensitive near-infrared (NIR)-fluorescence probe for tumors or lymph nodes in vivo. We synthesized ICG derivatives tagged with alkyl chains (ICG-Cn), and we examined NIR-fluorescence imaging for lymph nodes in the lower extremities of mice by using liposomally formulated ICG-Cn (LP-ICG-Cn) as well as conventional liposomally formulated ICG (LP-ICG) and ICG. Analysis with a noninvasive preclinical NIR-fluorescence imaging system revealed that LP-ICG-Cn accumulates in only the popliteal lymph node 1h after injection into the footpad, whereas LP-ICG and ICG accumulate in the popliteal lymph node and other organs like the liver. This result indicates that LP-ICG-Cn is a useful NIR-fluorescence probe for noninvasive in vivo bioimaging, especially for the sentinel lymph node. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Application of indocyanine green-fluorescence imaging to full-thickness cholecystectomy.

    Science.gov (United States)

    Morita, Kiyomi; Ishizawa, Takeaki; Tani, Keigo; Harada, Nobuhiro; Shimizu, Atsushi; Yamamoto, Satoshi; Takemura, Nobuyuki; Kaneko, Junichi; Aoki, Taku; Sakamoto, Yoshihiro; Sugawara, Yasuhiko; Hasegawa, Kiyoshi; Kokudo, Norihiro

    2014-05-01

    Fluorescence imaging using indocyanine green (ICG) has recently been applied to laparoscopic surgery to identify cancerous tissues, lymph nodes, and vascular anatomy. Here we report the application of ICG-fluorescence imaging to visualize the boundary between the liver and subserosal tissues of the gallbladder during laparoscopic full-thickness cholecystectomy. A patient with a potentially malignant gallbladder lesion was administered 2.5-mg intravenous ICG just before laparoscopic full-thickness cholecystectomy. Intraoperative fluorescence imaging enabled the real-time delineation of both extrahepatic bile duct anatomy and hepatic parenchyma throughout the procedure, which resulted in complete removal of subserosal tissues between liver and gallbladder. Safe and feasible ICG-fluorescence imaging can be widely applied to laparoscopic hepatobiliary surgery by utilizing a biliary excretion property of ICG. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  4. Indocyanine green enhanced surgery; principle, clinical applications and future research directions

    Directory of Open Access Journals (Sweden)

    Catalin Alius

    2018-05-01

    Full Text Available Over the past decade a new emergent technology has become very popular in all fields of surgery using Indocyanine green and near infrared fluorescent optical systems. This revolutionary approach overlaps conventional and near infrared images to produce highly informative intraoperative images on the anatomy and physiology of various tissues. Near infrared fluorescence is employed for perioperative angiography in vascular mapping, assessment of anastomoses, location of sentinel lymph nodes and delineation of biliary tree anatomy, highlighting tumours and metastatic deposits, improving surgical techniques and for many other uses. A lot of researchers have reported better surgical outcomes and technique innovations facilitated by this novel technology which although in its early stages, it lights up great interest worldwide. This article reviews the principle of the method, the properties of the fluorescent dye, the main clinical applications and discusses future research directions.

  5. Photodynamic actions of indocyanine green and trypan blue on human lens epithelial cells in vitro.

    Science.gov (United States)

    Melendez, Robert F; Kumar, Neeru; Maswadi, Saher M; Zaslow, Kenneth; Glickmank, Randolph D

    2005-07-01

    The purpose of this study was to evaluate the toxicity and photodynamic activity of indocyanine green (ICG) and trypan blue (TryB) on cultured human lensepithelial cells (LECs). Experimental study. Lens epithelial cell viability was assessed after treatment with ICG and TryB concentrations ranging from 0.025 to 5.0 mg/ml, and exposure to 806 nm diode laser. At ICG concentrations below 0.5 mg/ml, there was > or =75% cell viability; at higher ICG concentrations there was dose-dependent cytotoxicity in addition to loss of cellular viability due to ICG photosensitization. TryB had little cytotoxicity to the LECs: >80% cells were viable irrespective of the dye concentration or laser treatment. These data indicate that ICG may have application as a photosensitizer in the selective eradication of residual LECs after cataract surgery to reduce the incidence of posterior capsule opacification.

  6. Indocyanine green labeled with 123I for dynamic studies of the hepato-biliary system

    International Nuclear Information System (INIS)

    Lambrecht, R.M.; Ansari, A.N.; Wolf, A.P.; Atkins, H.L.

    1975-01-01

    This report summarizes the results to develop an iodine-123 labeled agent for dynamic studies of the hepato-biliary system. Iodine-123 is an ideal nuclide for radiopharmaceuticals, because of its short half-life (T/sub 1 / 2 / = 13.3 hr); its decay with a high abundance (83%) of 159 keV photons; and the reduced patient radiation exposure (a factor of 100 less than iodine-131). Indocyanine green, a tricarbanocyanine dye, was introduced by Heseltine and co-workers in 1956, has several characteristics which suggested that iodine-123 labeled ICG might be potentially useful for hepatic functional evaluation. The plasma clearance and biliary excretion kinetics of 123 I-ICG (in dogs) will be compared to 131 I-rose bengal and bromosulphalein labeled with iodine-125

  7. Model and methods to assess hepatic function from indocyanine green fluorescence dynamical measurements of liver tissue.

    Science.gov (United States)

    Audebert, Chloe; Vignon-Clementel, Irene E

    2018-03-30

    The indocyanine green (ICG) clearance, presented as plasma disappearance rate is, presently, a reliable method to estimate the hepatic "function". However, this technique is not instantaneously available and thus cannot been used intra-operatively (during liver surgery). Near-infrared spectroscopy enables to assess hepatic ICG concentration over time in the liver tissue. This article proposes to extract more information from the liver intensity dynamics by interpreting it through a dedicated pharmacokinetics model. In order to account for the different exchanges between the liver tissues, the proposed model includes three compartments for the liver model (sinusoids, hepatocytes and bile canaliculi). The model output dependency to parameters is studied with sensitivity analysis and solving an inverse problem on synthetic data. The estimation of model parameters is then performed with in-vivo measurements in rabbits (El-Desoky et al. 1999). Parameters for different liver states are estimated, and their link with liver function is investigated. A non-linear (Michaelis-Menten type) excretion rate from the hepatocytes to the bile canaliculi was necessary to reproduce the measurements for different liver conditions. In case of bile duct ligation, the model suggests that this rate is reduced, and that the ICG is stored in the hepatocytes. Moreover, the level of ICG remains high in the blood following the ligation of the bile duct. The percentage of retention of indocyanine green in blood, which is a common test for hepatic function estimation, is also investigated with the model. The impact of bile duct ligation and reduced liver inflow on the percentage of ICG retention in blood is studied. The estimation of the pharmacokinetics model parameters may lead to an evaluation of different liver functions. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. A standardized model for predicting flap failure using indocyanine green dye

    Science.gov (United States)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  9. DIEP flap customization using Fluobeam® indocyanine green tissue perfusion assessment with large previous abdominal scar

    Directory of Open Access Journals (Sweden)

    Michael A. Fallucco

    2017-06-01

    Full Text Available The Fluobeam® is a portable, near-infrared camera that is held and controlled by the surgeon to visualize tissue perfusion using indocyanine green (ICG fluorescence imaging. This case report describes how data obtained from ICG imaging allows intraoperative customization in a previously surgically scarred abdomen during autologous Deep Inferior Epigastric Artery Perforator (DIEP flap bilateral breast reconstruction. The outcome was successful breast mound recreation without fat necrosis.

  10. In Vitro Efficacy and Mechanistic Role of Indocyanine Green as a Photodynamic Therapy Agent for Human Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Mamoon, A.; Gamal-Eldeen, A; Ruppel, M; Smith, R; Tsang, T; Miller, L

    2009-01-01

    Photodynamic therapy (PDT) is a promising treatment for superficial cancer. However, poor therapeutic results have been reported for melanoma, due to the high melanin content. Indocyanine green (ICG) has near infrared absorption (700-800nm) and melanins do not absorb strongly in this area. This study explores the efficiency of ICG as a PDT agent for human melanoma, and its mechanistic role in the cell death pathway.

  11. Effects of indocyanine green videoangiography and electrophysiological monitoring on surgery for intracranial aneurysms

    International Nuclear Information System (INIS)

    Arai, Yoshikazu; Kitai, Ryuhei; Awara, Kosuke

    2011-01-01

    We analyzed the outcome of 62 consecutive patients with unruptured intracranial aneurysm treated by surgical clipping. Thirty-one cases were operated without intraoperative monitoring, 17 cases with indocyanine green videoangiography (ICGA), and 14 cases with electrophysiological monitoring (EPM) in addition to ICGA. Complete obliteration of the aneurysm was confirmed in all 62 cases. Diffusion-weighted imaging of MRI disclosed no ischemic lesions after surgery in any of the cases. Asymptomatic venous infarction was detected by CT study in 2 cases. Cranial nerve palsy occurred in 4 cases but EPM could not detect it. There was no difference among the group without monitoring, the group with ICGA and the group with ICGA and EPM. The mortality and morbidity of all cases was calculated as 0% and 6.5%, respectively. ICGA appeared to be useful in surgery for aneurysms encasing perforators or for repair of problems such as premature rupture. eicosapentaenoic acid (EPA) seemed effective in surgery for anterior choroidal artery aneurysms or aneurysms requiring trapping before clipping. However, monitoring would not have been effective without extensive dissection of aneurysms, suggesting that basic microsurgical techniques are crucial for successful surgery. (author)

  12. Indocyanine green loaded graphene oxide for high-efficient photoacoustic tumor therapy

    Directory of Open Access Journals (Sweden)

    Baoyun Yan

    2016-07-01

    Full Text Available Photoacoustic therapy, using the photoacoustic effect of agents for selectively killing tumor cells, has shown promising for treating tumor. Utilization of high optical absorption probes can help to effectively improve the photoacoustic therapy efficiency. Herein, we report a novel high-absorption photoacoustic probe that is composed of indocyanine green (ICG and graphene oxide (GO, entitled GO-ICG, for photoacoustic therapy. The attached ICG with narrow absorption spectral profile has strong optical absorption in the infrared region. The absorption spectrum of the GO-ICG solution reveals that the GO-ICG particles exhibited a 10-fold higher absorbance at 780nm (its peak absorbance as compared with GO. Importantly, ICG’s fluorescence is quenched by GO via fluorescence resonance energy transfer. As a result, GO-ICG can high-efficiently convert the absorbed light energy to acoustic wave under pulsed laser irradiation. We further demonstrate that GO-ICG can produce stronger photoacoustic wave than the GO and ICG alone. Moreover, we conjugate this contrast agent with integrin αvβ3 mono-clonal antibody to molecularly target the U87-MG human glioblastoma cells for selective tumor cell killing. Finally, our results testify that the photoacoustic therapy efficiency of GO-ICG is higher than the existing photoacoustic therapy agent. Our work demonstrates that GO-ICG is a high-efficiency photoacoustic therapy agent. This novel photoacoustic probe is likely to be an available candidate for tumor therapy.

  13. Tracheal anastomosis using indocyanine green dye enhanced fibrinogen with a near-infrared diode laser

    Science.gov (United States)

    Auteri, Joseph S.; Jeevanandam, Valluvan; Oz, Mehmet C.; Libutti, Steven K.; Kirby, Thomas J.; Smith, Craig R.; Treat, Michael R.

    1990-06-01

    A major obstacle to lung transplantation and combined heart- lung transplantation is dehiscence of the tracheobronchial anastomosis. We explored the possibility of laser welded anastomoses in canine tracheas in vivo. Laser anastomoses were performed on three-quarter circumferential anterior tracheotomies. A continous wave diode laser (808 +1 nm) at a power density of 9.6 watts/cm was used. Human fibrinogen was mixed with indocyanine green dye (ICG, max absorbance 805 nm) and applied to the anastomosis site prior to laser exposure. Animals were sacrificed at 0, 21 and 28 days post-operatively. At sacrifice weld bursting pressures were measured by raising intratracheal pressure using forced ventilation via an endotracheal tube. Sutured and laser welded anastomoses had similar bursting pressures, and exhibited satisfactory histologic evidence of healing. However, compared to polypropylene sutured controls, the laser welded anastomoses exhibited less peritracheal inflammatory reaction and showed visibly smoother luminal surfaces at 21 and 28 days post- operatively. Tracheal anastomosis using ICG dye enhanced fibrinogen combined with the near-infrared diode laser is a promising extension of the technology of laser tissue fusion and deserves further study.

  14. Targeted imaging of ovarian cancer cells using viral nanoparticles doped with indocyanine green

    Science.gov (United States)

    Guerrero, Yadir; Bahmani, Baharak; Jung, Bonsu; Vullev, Valentine; Kundra, Vikas; Anvari, Bahman

    2013-03-01

    Our group has constructed a new type of viral nanoparticles (VNPs) from genome-depleted plant infecting brome mosaic virus (BMV) that encapsulates the FDA-approved near infrared (NIR) indocyanine green (ICG)[1]. We refer to these VNPs as optical viral ghosts (OVGs) since the constructs lack the genomic content of wild-type BMV. One of our areas of interest is the application of OVGs for real-time intraoperative NIR fluorescence imaging of small peritoneal ovarian tumor nodules. We target human epidermal growth factor receptor-2 (HER-2) expression in ovarian cancer as a biomarker associated with ovarian cancer, since its over-expression is linked to the disease's progression to death. We functionalize the OVGs with anti-HER-2 monoclonal antibodies using reductive amination methods. We used fluorescence imaging to visualize the SKOV-3 cells (high HER-2 expression) after incubation with free ICG, OVGs, and functionalized OVGs. Our results suggest the possibility of using anti-HER2 conjugated OVGs in conjunction with cytoreductive surgery to detect small tumor nodules (<5cm) which currently are not excised during surgery.

  15. Indocyanine green videoangiography "in negative": definition and usefulness in intracranial dural arteriovenous fistulae.

    Science.gov (United States)

    Simal Julián, Juan Antonio; Miranda Lloret, Pablo; Aparici Robles, Fernando; Beltrán Giner, Andrés; Botella Asunción, Carlos

    2013-09-01

    Indocyanine green videoangiography (IGV) raises important limitations when we use it in vascular pathology, especially in cases with arterialization of the venous system such as arteriovenous malformations and fistulae. Our objective was to provide a simple procedure that overcomes the limitations of conventional IGV. We define IGV in negative (IGV-IN), so-called because, in its first phase, the vessel to analyze is clipped, and we report 3 cases of intracranial dural arteriovenous fistulae treated with this procedure. In 2011, we applied IGV-IN to 3 patients at our center with Borden type III intracranial arteriovenous fistulae. In all 3 cases, IGV-IN enabled both diagnosis and post-dural arteriovenous fistula exclusion control in 1 integrated procedure no longer than 1 minute, requiring only 1 visualization. IGV-IN is an improvement over the conventional IGV method and is able to provide more information in a shorter period of time. It is an intuitive and highly visual procedure, and, more importantly, it is reversible. Studies with larger samples are necessary to determine whether IGV-IN can further reduce the need for postoperative digital subtraction angiography.

  16. Leveraging Engineering of Indocyanine Green-Encapsulated Polymeric Nanocomposites for Biomedical Applications.

    Science.gov (United States)

    Han, Ya-Hui; Kankala, Ranjith Kumar; Wang, Shi-Bin; Chen, Ai-Zheng

    2018-05-24

    In recent times, photo-induced therapeutics have attracted enormous interest from researchers due to such attractive properties as preferential localization, excellent tissue penetration, high therapeutic efficacy, and minimal invasiveness, among others. Numerous photosensitizers have been considered in combination with light to realize significant progress in therapeutics. Along this line, indocyanine green (ICG), a Food and Drug Administration (FDA)-approved near-infrared (NIR, >750 nm) fluorescent dye, has been utilized in various biomedical applications such as drug delivery, imaging, and diagnosis, due to its attractive physicochemical properties, high sensitivity, and better imaging view field. However, ICG still suffers from certain limitations for its utilization as a molecular imaging probe in vivo, such as concentration-dependent aggregation, poor in vitro aqueous stability and photodegradation due to various physicochemical attributes. To overcome these limitations, much research has been dedicated to engineering numerous multifunctional polymeric composites for potential biomedical applications. In this review, we aim to discuss ICG-encapsulated polymeric nanoconstructs, which are of particular interest in various biomedical applications. First, we emphasize some attractive properties of ICG (including physicochemical characteristics, optical properties, metabolic features, and other aspects) and some of its current limitations. Next, we aim to provide a comprehensive overview highlighting recent reports on various polymeric nanoparticles that carry ICG for light-induced therapeutics with a set of examples. Finally, we summarize with perspectives highlighting the significant outcome, and current challenges of these nanocomposites.

  17. Recent advances in near-infrared fluorescence-guided imaging surgery using indocyanine green.

    Science.gov (United States)

    Namikawa, Tsutomu; Sato, Takayuki; Hanazaki, Kazuhiro

    2015-12-01

    Near-infrared (NIR) fluorescence imaging has better tissue penetration, allowing for the effective rejection of excitation light and detection deep inside organs. Indocyanine green (ICG) generates NIR fluorescence after illumination by an NIR ray, enabling real-time intraoperative visualization of superficial lymphatic channels and vessels transcutaneously. The HyperEye Medical System (HEMS) can simultaneously detect NIR rays under room light to provide color imaging, which enables visualization under bright light. Thus, NIR fluorescence imaging using ICG can provide for excellent diagnostic accuracy in detecting sentinel lymph nodes in cancer and microvascular circulation in various ischemic diseases, to assist us with intraoperative decision making. Including HEMS in this system could further improve the sentinel lymph node mapping and intraoperative identification of blood supply in reconstructive organs and ischemic diseases, making it more attractive than conventional imaging. Moreover, the development of new laparoscopic imaging systems equipped with NIR will allow fluorescence-guided surgery in a minimally invasive setting. Future directions, including the conjugation of NIR fluorophores to target specific cancer markers might be realistic technology with diagnostic and therapeutic benefits.

  18. Visualization of subcapsular hepatic malignancy by indocyanine-green fluorescence imaging during laparoscopic hepatectomy.

    Science.gov (United States)

    Kudo, Hiroki; Ishizawa, Takeaki; Tani, Keigo; Harada, Nobuhiro; Ichida, Akihiko; Shimizu, Atsushi; Kaneko, Junichi; Aoki, Taku; Sakamoto, Yoshihiro; Sugawara, Yasuhiko; Hasegawa, Kiyoshi; Kokudo, Norihiro

    2014-08-01

    Although laparoscopic hepatectomy has increasingly been used to treat cancers in the liver, the accuracy of intraoperative diagnosis may be inferior to that of open surgery because the ability to visualize and palpate the liver surface during laparoscopy is relatively limited. Fluorescence imaging has the potential to provide a simple compensatory diagnostic tool for identification of cancers in the liver during laparoscopic hepatectomy. In 17 patients who were to undergo laparoscopic hepatectomy, 0.5 mg/kg body weight of indocyanine green (ICG) was administered intravenously within the 2 weeks prior to surgery. Intraoperatively, a laparoscopic fluorescence imaging system obtained fluorescence images of its surfaces during mobilization of the liver. In all, 16 hepatocellular carcinomas (HCCs) and 16 liver metastases (LMs) were resected. Of these, laparoscopic ICG fluorescence imaging identified 12 HCCs (75%) and 11 LMs (69%) on the liver surfaces distributed over Couinaud's segments 1-8, including the 17 tumors that had not been identified by visual inspections of normal color images. The 23 tumors that were identified by fluorescence imaging were located closer to the liver surfaces than another nine tumors that were not identified by fluorescence imaging (median [range] depth 1 [0-5] vs. 11 [8-30] mm; p fluorescence imaging enables real-time identification of subcapsular liver cancers, thus facilitating estimation of the required extent of hepatic mobilization and determination of the location of an appropriate hepatic transection line.

  19. [Place of indocyanine green coupled with fluorescence imaging in research of breast cancer sentinel node].

    Science.gov (United States)

    Vermersch, Charlotte; Raia Barjat, Tiphaine; Perrot, Marianne; Lima, Suzanne; Chauleur, Céline

    2016-04-01

    The sentinel node has a fundamental role in the management of early breast cancer. Currently, the double detection of blue and radioisotope is recommended. But in common practice, many centers use a single method. However, with a single detection, the risk of false negatives and the identification failure rate increase to a significant extent and the number of sentinel lymph node detected and removed is not enough. Furthermore, the tracers used until now show inconveniences. The purpose of this work is to present a new method of detection, using the green of indocyanine coupled with fluorescence imaging, and to compare it with the already existing methods. The method combined by fluorescence and isotopic is reliable, sure, of fast learning and could constitute a good strategy of detection. The major interest is to obtain a satisfactory number of sentinel nodes. The profit could be even more important for overweight patients. The fluorescence used alone is at the moment not possible. Wide ranging studies are necessary. The FLUOTECH, randomized study of 100 patients, comparing the isotopic method of double isotope technique and fluorescence, is underway to confirm these data. Copyright © 2016 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.

  20. In vitro efficiency and mechanistic role of indocyanine green as photodynamic therapy agent for human melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Mamoon, A.M.; Miller, L.; Gamal-Eldeen, A. M.; Ruppel, M. E.; Smith, R. J.; Tsang, T.; Miller, L. M.

    2009-05-02

    Photodynamic therapy (PDT) is a promising treatment for superficial cancer. However, poor therapeutic results have been reported for melanoma, due to the high melanin content. Indocyanine green (ICG) has near infrared absorption (700-800 nm) and melanins do not absorb strongly in this area. This study explores the efficiency of ICG as a PDT agent for human melanoma, and its mechanistic role in the cell death pathway. Human skin melanoma cells (Sk-Mel-28) were incubated with ICG and exposed to a low power Ti:Sapphire laser. Synchrotron-assisted Fourier transform infrared microspectroscopy and hierarchical cluster analysis were used to assess the cell damage and changes in lipid, protein, and nucleic acids. The cell death pathway was determined by analysis of cell viability and apoptosis and necrosis markers. In the cell death pathway, {sup 1}O{sub 2} generation evoked rapid multiple consequences that trigger apoptosis after laser exposure for only 15min including the release of cytochrome c, the activation of total caspases, caspase-3, and caspase-9, the inhibition of NF-{Kappa}B P65, and the enhancement of DNA fragmentation, and histone acetylation. ICG/PDT can efficiently and rapidly induce apoptosis in human melanoma cells and it can be considered as a new therapeutic approach for topical treatment of melanoma.

  1. Indocyanine green plasma disappearance rate during the anhepatic phase of orthotopic liver transplantation.

    Science.gov (United States)

    Bruegger, Lukas; Studer, Peter; Schmid, Stefan W; Pestel, Gunther; Reichen, Juerg; Seiler, Christian; Candinas, Daniel; Inderbitzin, Daniel

    2008-01-01

    Non-invasive pulse spectrophotometry to measure indocyanine green (ICG) elimination correlates well with the conventional invasive ICG clearance test. Nevertheless, the precision of this method remains unclear for any application, including small-for-size liver remnants. We therefore measured ICG plasma disappearance rate (PDR) during the anhepatic phase of orthotopic liver transplantation using pulse spectrophotometry. Measurements were done in 24 patients. The median PDR after exclusion of two outliers and two patients with inconstant signal was 1.55%/min (95% confidence interval [CI]=0.8-2.2). No correlation with patient age, gender, body mass, blood loss, administration of fresh frozen plasma, norepinephrine dose, postoperative albumin (serum), or difference in pre and post transplant body weight was detected. In conclusion, we found an ICG-PDR different from zero in the anhepatic phase, an overestimation that may arise in particular from a redistribution into the interstitial space. If ICG pulse spectrophotometry is used to measure functional hepatic reserve, the verified average difference from zero (1.55%/min) determined in our study needs to be taken into account.

  2. Toxicity profiles of subretinal indocyanine green, Brilliant Blue G, and triamcinolone acetonide: a comparative study

    DEFF Research Database (Denmark)

    Ejstrup, Rasmus; Dornonville de la Cour, Morten; Heegaard, Steffen

    2012-01-01

    BACKGROUND: This study introduces a novel porcine model to examine the histopathological and electrophysiological consequences of retinotoxicity exerted by dyes commonly used for internal limiting membrane (ILM) staining. METHODS: Indocyanine green (ICG) 0.5 mg/ml, Brilliant Blue G (BBG) 0.25 mg....../ml and triamcinolone acetonide (TA) 13 mg/ml was injected subretinally in 12 vitrectomized pig eyes. At 6 weeks, retinas were examined by multifocal electroretinography (mfERG), ophthalmoscopy, fluorescein angiograpy, histopathology, and apoptosis assay. RESULTS: mfERG responses were significantly lower in ICG......-injected eyes than in healthy fellow eyes (p¿=¿0.039). The ratio between injected eyes and healthy fellow eyes was lower in the ICG group than in the BBG (p¿=¿0.009) and TA group (p¿=¿0.025). No difference between BBG and TA existed. All retinas were reattached, and fluorescein angiographies showed a window...

  3. Symmetricity analysis of time to peak parameter of indocyanine green dynamics

    Science.gov (United States)

    An, Yuri; Lee, Jungsul; Choi, Chulhee

    2013-03-01

    We have previously discovered that near-infrared optical imaging of indocyanine green (ICG) signal and analyzing its dynamics can be applied for measurement of blood perfusion rate and detection of Raynaud's phenomenon (RP). Especially, RP is closely associated with abnormal vasomotor responses and can progress to tissue necrosis due to excessively sustained vasoconstriction. Therefore, early detecting of RP is one of important implication to prevent tissue damage from peripheral vascular disorders. In the present study, we propose new analysis and scoring method of symmetricity of Tmax value of left and right extremities. Moreover, this symmetricity analysis can give further information about microvascular insufficiency. For validation of the proposed method, we tested whether the segmental and paired analysis of Tmax value (time-to-peak) of ICG dynamics can be used for sensitive diagnosis of microvascular abnormalities which cannot be detected by conventional methods. From the near-infrared images of diabetes mellitus patients with vascular complications, the trend of asymmetry in Tmax value was observed. We assumed that decreasing local blood perfusion by autonomic nerve dysfunction causes the asymmetric Tmax value of right and left feet. These results collectively indicate that the proposed method can be used as a useful diagnostic tool for RP or other microvascular disorders.

  4. Indocyanine green videoangiography (ICGV)-guided surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS).

    Science.gov (United States)

    d'Avella, Elena; Volpin, Francesco; Manara, Renzo; Scienza, Renato; Della Puppa, Alessandro

    2013-03-01

    Maximal safe resection is the goal of correct surgical treatment of parasagittal meningiomas, and it is intimately related to the venous anatomy both near and directly involved by the tumor. Indocyanine green videoangiography (ICGV) has already been advocated as an intra-operative resourceful technique in brain tumor surgery for the identification of vessels. The aim of this study was to investigate the role of ICGV in surgery of parasagittal meningiomas occluding the superior sagittal sinus (SSS). In this study, we prospectively analyzed clinical, radiological and intra-operative findings of patients affected by parasagittal meningioma occluding the SSS, who underwent ICGV assisted-surgery. Radiological diagnosis of complete SSS occlusion was pre-operatively established in all cases. ICGV was performed before dural opening, before and during tumor resection, at the end of the procedure. Five patients were included in our study. In all cases, ICGV guided dural opening, tumor resection, and venous management. The venous collateral pathway was easily identified and preserved in all cases. Radical resection was achieved in four cases. Surgery was uneventful in all cases. Despite the small number of patients, our study shows that ICG videoangiography could play a crucial role in guiding surgery of parasagittal meningioma occluding the SSS. Further studies are needed to define the role of this technique on functional and oncological outcome of these patients.

  5. Development and validation of a custom made indocyanine green fluorescence lymphatic vessel imager

    Science.gov (United States)

    Pallotta, Olivia J.; van Zanten, Malou; McEwen, Mark; Burrow, Lynne; Beesley, Jack; Piller, Neil

    2015-06-01

    Lymphoedema is a chronic progressive condition often producing significant morbidity. An in-depth understanding of an individual's lymphatic architecture is valuable both in the understanding of underlying pathology and for targeting and tailoring treatment. Severe lower limb injuries resulting in extensive loss of soft tissue require transposition of a flap consisting of muscle and/or soft tissue to close the defect. These patients are at risk of lymphoedema and little is known about lymphatic regeneration within the flap. Indocyanine green (ICG), a water-soluble dye, has proven useful for the imaging of lymphatic vessels. When injected into superficial tissues it binds to plasma proteins in lymph. By exposing the dye to specific wavelengths of light, ICG fluoresces with near-infrared light. Skin is relatively transparent to ICG fluorescence, enabling the visualization and characterization of superficial lymphatic vessels. An ICG fluorescence lymphatic vessel imager was manufactured to excite ICG and visualize real-time fluorescence as it travels through the lymphatic vessels. Animal studies showed successful ICG excitation and detection using this imager. Clinically, the imager has assisted researchers to visualize otherwise hidden superficial lymphatic pathways in patients postflap surgery. Preliminary results suggest superficial lymphatic vessels do not redevelop in muscle flaps.

  6. Thermal and infrared-diode laser effects on indocyanine-green-treated corneal collagen

    Science.gov (United States)

    Timberlake, George T.; Patmore, Ann; Shallal, Assaad; McHugh, Dominic; Marshall, John

    1993-07-01

    It has been suggested that laser welds of collagenous tissues form by interdigitation and chemical bonding of thermally 'unraveled' collagen fibrils. We investigated this proposal by attempting to weld highly collagenous, avascular corneal tissue with an infrared (IR) diode laser as follows. First, the temperature at which corneal collagen shrinks and collagen fibrils 'split' into subfibrillary components was determined. Second, since use of a near-IR laser wavelength necessitated addition of an absorbing dye (indocyanine green (ICG) to the cornea, we measured absorption spectra of ICG-treated tissue to ensure that peak ICG absorbance did not change markedly when ICG was present in the cornea. Third, using gel electrophoresis of thermally altered corneal collagen, we searched for covalently crosslinked compounds predicted by the proposed welding mechanism. Finally, we attempted to weld partial thickness corneal incisions infused with ICG. Principal experimental findings were as follows: (1) Human corneal (type I) collagen splits into subfibrillary components at approximately 63 degree(s)C, the same temperature that produces collagen shrinkage. (2) Peak ICG absorption does not change significantly in corneal stroma or with laser heating. (3) No evidence was found for the formation of novel compounds or the loss of proteins as a result of tissue heating. All tissue treated with ICG, however, exhibited a novel 244 kD protein band indicating chemical activity between collagen and corneal stromal components. (4) Laser welding corneal incisions was unsuccessful possibly due to shrinkage of the sides of the incision, lack of incision compression during heating, or a less than optimal combination of ICG concentration and radiant exposure. In summary, these experiments demonstrate the biochemical and morphological complexity of ICG-enhanced IR laser-tissue welding and the need for further investigation of laser welding mechanisms.

  7. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-08-01

    There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here.

  8. Laparoscopic Sentinel Node Mapping in Endometrial Cancer After Hysteroscopic Injection of Indocyanine Green.

    Science.gov (United States)

    Martinelli, Fabio; Ditto, Antonino; Bogani, Giorgio; Signorelli, Mauro; Chiappa, Valentina; Lorusso, Domenica; Haeusler, Edward; Raspagliesi, Francesco

    2017-01-01

    To report the detection rate (DR) of sentinel lymph nodes (SLNs) in endometrial cancer (EC) patients after hysteroscopic injection of indocyanine green (ICG) and laparoscopic near-infrared (L-NIR) fluorescence mapping. Prospectively collected data (Canadian Task Force classification II-2). Gynecologic oncology referral center. Consecutive patients with apparent early-stage endometrioid EC scheduled for surgical treatment: total laparoscopic hysterectomy, bilateral salpingo-oophorectomy, SLN mapping. The mapping technique consisted in an intraoperative hysteroscopic peritumoral injection of 5 mg ICG followed by L-NIR fluorescence mapping. Evaluations of the SLN DR and sites of mapping were performed. A total of 57 procedures was performed. Patient mean age was 60 years (range, 28-80) and mean body mass index was 28.2 kg/m 2 (range, 19-43). At least 1 SLN was detected in 89.5% of the whole population (51/57). After the first 16 cases, L-NIR camera technical improvement led to a 95% DR (39/41). The mean number of harvested SLNs was 4.1 (range. 1-8), and in 47% of cases SLNs mapped to aortic nodes (24/51). Bilateral pelvic mapping was found in 74.5% of cases (38/51). Three patients had SLN metastases: 1 in the pelvic area only, 1 both in the pelvic and aortic area, and 1 presented with 2 metastatic aortic SLNs with negative pelvic SLNs. Overall, 2 of 3 node-positive patients (67%) had aortic SLN involvement. No adverse events were reported. Laparoscopic SLN mapping after the hysteroscopic injection of ICG has comparable DRs with both radioactive tracer series and ICG series with cervical injection, overcoming the need for radioactive substances. Hysteroscopic injection leads to a higher mapping in the aortic area compared with cervical injection. Further investigation is warranted on this topic. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  9. Mechanistic background and clinical applications of indocyanine green fluorescence imaging of hepatocellular carcinoma.

    Science.gov (United States)

    Ishizawa, Takeaki; Masuda, Koichi; Urano, Yasuteru; Kawaguchi, Yoshikuni; Satou, Shouichi; Kaneko, Junichi; Hasegawa, Kiyoshi; Shibahara, Junji; Fukayama, Masashi; Tsuji, Shingo; Midorikawa, Yutaka; Aburatani, Hiroyuki; Kokudo, Norihiro

    2014-02-01

    Although clinical applications of intraoperative fluorescence imaging of liver cancer using indocyanine green (ICG) have begun, the mechanistic background of ICG accumulation in the cancerous tissues remains unclear. In 170 patients with hepatocellular carcinoma cells (HCC), the liver surfaces and resected specimens were intraoperatively examined by using a near-infrared fluorescence imaging system after preoperative administration of ICG (0.5 mg/kg i.v.). Microscopic examinations, gene expression profile analysis, and immunohistochemical staining were performed for HCCs, which showed ICG fluorescence in the cancerous tissues (cancerous-type fluorescence), and HCCs showed fluorescence only in the surrounding non-cancerous liver parenchyma (rim-type fluorescence). ICG fluorescence imaging enabled identification of 273 of 276 (99%) HCCs in the resected specimens. HCCs showed that cancerous-type fluorescence was associated with higher cancer cell differentiation as compared with rim-type HCCs (P Fluorescence microscopy identified the presence of ICG in the canalicular side of the cancer cell cytoplasm, and pseudoglands of the HCCs showed a cancerous-type fluorescence pattern. The ratio of the gene and protein expression levels in the cancerous to non-cancerous tissues for Na(+)/taurocholate cotransporting polypeptide (NTCP) and organic anion-transporting polypeptide 8 (OATP8), which are associated with portal uptake of ICG by hepatocytes that tended to be higher in the HCCs that showed cancerous-type fluorescence than in those that showed rim-type fluorescence. Preserved portal uptake of ICG in differentiated HCC cells by NTCP and OATP8 with concomitant biliary excretion disorders causes accumulation of ICG in the cancerous tissues after preoperative intravenous administration. This enables highly sensitive identification of HCC by intraoperative ICG fluorescence imaging.

  10. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-01-01

    Abstract. There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here. PMID:27533438

  11. Intraoperative Detection of Superficial Liver Tumors by Fluorescence Imaging Using Indocyanine Green and 5-aminolevulinic Acid.

    Science.gov (United States)

    Kaibori, Masaki; Matsui, Kosuke; Ishizaki, Morihiko; Iida, Hiroya; Okumura, Tadayoshi; Sakaguchi, Tatsuma; Inoue, Kentaro; Ikeura, Tsukasa; Asano, Hiroaki; Kon, Masanori

    2016-04-01

    Indocyanine green (ICG) and the porphyrin precursor 5-aminolevulinic acid (5-ALA) have been approved as fluorescence imaging agents in the clinical setting. This study evaluated the usefulness of fluorescence imaging with both ICG and 5-ALA for intraoperative identification of latent small liver tumors. There were 48 patients who had main tumors within 5 mm of the liver surface. 5-ALA hydrochloride was orally administered to patients 3 h before surgery. ICG had been intravenously injected within 14 days prior to surgery. Intraoperatively, after visual inspection, manual palpation and ultrasonography fluorescence images of the liver surface were obtained with ICG and 5-ALA prior to resection. With ICG, the sensitivity, specificity and accuracy for detecting the preoperatively identified main tumors were 96%, 50% and 94%, respectively. Twelve latent small tumors were newly detected on the liver surface using ICG, five of which proved to be carcinomas. With 5-ALA, the sensitivity, specificity and accuracy for detecting the main tumors were 57%, 100% and 58%, respectively. Five latent small tumors were newly detected using 5-ALA; all were carcinomas. Overall, five new tumors were detected by both ICG and 5-ALA fluorescence imaging; two were hepatocellular carcinomas (HCCs) and three were metastases of colorectal cancer. The sensitivity and specificity of ICG fluorescence imaging for main tumor detection were relatively high and low, respectively, but the opposite was true of 5-ALA imaging. Fluorescence imaging using 5-ALA may provide greater specificity in the detection of surface-invisible malignant liver tumors than using ICG fluorescence imaging alone. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  12. Intradermal indocyanine green for in vivo fluorescence laser scanning microscopy of human skin: a pilot study.

    Directory of Open Access Journals (Sweden)

    Constanze Jonak

    Full Text Available BACKGROUND: In clinical diagnostics, as well as in routine dermatology, the increased need for non-invasive diagnosis is currently satisfied by reflectance laser scanning microscopy. However, this technique has some limitations as it relies solely on differences in the reflection properties of epidermal and dermal structures. To date, the superior method of fluorescence laser scanning microscopy is not generally applied in dermatology and predominantly restricted to fluorescein as fluorescent tracer, which has a number of limitations. Therefore, we searched for an alternative fluorophore matching a novel skin imaging device to advance this promising diagnostic approach. METHODOLOGY/PRINCIPAL FINDINGS: Using a Vivascope®-1500 Multilaser microscope, we found that the fluorophore Indocyanine-Green (ICG is well suited as a fluorescent marker for skin imaging in vivo after intradermal injection. ICG is one of few fluorescent dyes approved for use in humans. Its fluorescence properties are compatible with the application of a near-infrared laser, which penetrates deeper into the tissue than the standard 488 nm laser for fluorescein. ICG-fluorescence turned out to be much more stable than fluorescein in vivo, persisting for more than 48 hours without significant photobleaching whereas fluorescein fades within 2 hours. The well-defined intercellular staining pattern of ICG allows automated cell-recognition algorithms, which we accomplished with the free software CellProfiler, providing the possibility of quantitative high-content imaging. Furthermore, we demonstrate the superiority of ICG-based fluorescence microscopy for selected skin pathologies, including dermal nevi, irritant contact dermatitis and necrotic skin. CONCLUSIONS/SIGNIFICANCE: Our results introduce a novel in vivo skin imaging technique using ICG, which delivers a stable intercellular fluorescence signal ideal for morphological assessment down to sub-cellular detail. The application of

  13. Indocyanine green-assisted internal limiting membrane peeling in macular hole surgery: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Yan Wu

    Full Text Available BACKGROUND: The opinion of application of indocyanine green (ICG in the macular hole surgery was contradictory. Here we conducted a meta-analysis to evaluate the effect of in internal limiting membrane (ILM peeling for macular hole surgery. METHODS AND FINDINGS: We searched electronic databases for comparative studies published before July 2012 of ILM peeling with and without ICG. Twenty-two studies including 1585 eyes were included. Visual acuity (VA improvement, including the postoperative rate of ≥20/40 VA gained (OR, 0.65; 95% CI, 0.43 to 0.97; P = 0.033 and increased LogMAR (WMD, -0.09; 95% CI, -0.16 to -0.02; P = 0.011, was less in the ICG group. The risk of visual field defects was greater in the ICG group than in the non-ICG group. There was no significant difference in the rate of anatomical outcomes between ILM peeling procedures performed with and without ICG. RPE changes and other postoperative complications were not significantly different between the ICG and non-ICG groups. An additional analysis showed that the VA improvement of the ICG group was less than the non-ICG group only within the first year of follow up. A subgroup analysis showed that the rate of VA improvement was lower in the ICG group than in other adjuncts group. A higher rate of secondary closure and less VA improvement were observed in a high proportion (>0.1% of the ICG group. A sensitivity analysis after the randomized-controlled trials were excluded from the meta-analysis demonstrated no differences compared with the overall results. CONCLUSIONS: This meta-analysis demonstrated that there is no evidence of clinical superiority in outcomes for ICG-assisted ILM peeling procedure over the non-ICG one. The toxicity of ICG should be considered when choosing the various staining methods.

  14. [Sentinel node detection using optonuclear probe (gamma and fluorescence) after green indocyanine and radio-isotope injections].

    Science.gov (United States)

    Poumellec, M-A; Dejode, M; Figl, A; Darcourt, J; Haudebourg, J; Sabah, Y; Voury, A; Martaens, A; Barranger, E

    2016-04-01

    Assess the biopsy's feasibility of the sentinel lymph node biopsy (SLNB) using optonuclear probe after of indocyanine green (ICG) and radio-isotope (RI) injections. Twenty-one patients with a localized breast cancer and unsuspicious axillary nodes underwent a SLNB after both injections of ICG and radio-isotope. One or more SLN were identified on the 21 patients (identification rate of 100%). The median number SLN was 2 (1-3). Twenty SLN were both radio-actives and fluorescents (54.1%), 11 fluorescent only (29.7%) and 6 were only radio-actives (16.2%). Seven patients had a metastatic SLN (8 SLN overall). Among them, only one had a micrometastasic SLN, 5 others had a macrometastatic SLN and one patient had two macrometastatic SLNs. Among the 8 metastatic SLN, 5 were both fluorescent and radioactive, 2 were only fluorescent and 1 was only radioactive. Detection SLN using optonuclear probe after indocyanine green and radio-isotope injections is effective and could be, after validation by randomized trial, a reliable alternative to the blue dye injection for teams who consider that combined detection as the reference. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  15. Two Cases of Severe Degeneration of the Macula Following Vitrectomy with Indocyanine Green-Assisted Internal Limiting Membrane Peeling for Idiopathic Macular Hole

    OpenAIRE

    Inoue, Junji; Sakuma, Toshiro; Kiyokawa, Masatoshi; Kobayashi, Yasuhiko; Takebayashi, Hiroshi; Mizota, Atsushi; Tanaka, Minoru

    2008-01-01

    We describe three eyes of two cases of severe degeneration of the macula following vitrectomy with indocyanine green-assisted internal limiting membrane peeling for idiopathic macular hole. We need to remember the possibility of these complications and have to select the procedures that are safest to use for macular hole surgery.

  16. Hepatic blood flow determination. A comparison of 99mTc-diethyl-IDA and indocyanine green as hepatic blood flow indicators in man

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Winkler, K

    1987-01-01

    99mTc-diethyl-acetanilide-iminodiacetic acid (IDA) was compared with indocyanine green (ICG) as an indicator of hepatic blood flow (HBF). Twelve subjects (8 with cirrhosis, 2 with fatty liver, one with pancreatitis, and one with intestinal angina) were studied during hepatic vein catheterization...

  17. Feasibility of simultaneous sodium fluorescein and indocyanine green injection in neurosurgical procedures.

    Science.gov (United States)

    Acerbi, F; Restelli, F; Broggi, M; Schiariti, M; Ferroli, P

    2016-07-01

    The objective of this study is to assess the feasibility of simultaneous Sodium Fluorescein (SF) and Indocyanine Green (ICG) injection during neurosurgical procedures. Three patients harboring a high-grade glioma (HGG) were retrospectively identified in the surgical database of the Neurosurgical Unit 2 at the Foundation IRCCS Istituto Neurologico C. Besta in Milan, by having received intraoperatively both SF for tumor resection and ICG for vasculature angiographic studies in the same surgical procedure. We identified 2 males and 1 female (age range 25-60). Lesions were located in the left temporo-polar area and hippocampus (1 case), right superior frontal gyrus (1 case), left supplementary motor area (1 case). All the three lesions showed Magnetic Resonance Imaging (MRI) characteristics of HGG and, for this reason, in all patients a fluorescein-guided tumor removal was proposed. In the same surgical procedure ICG videoangiography was considered necessary in order to study arterial and venous vasculature, given by the strict relation of the tumor with an unexpected Posterior Communicating Artery (PComA) aneurysm in one case and with cortical drainage veins complexes in the other two cases. In all cases a microscope equipped with both YELLOW560 and IR800 integrated filters (Pentero 900, Carl Zeiss, Oberkorchen, Germany) was used. Fluorescein was i.v. injected at a dose of 5mg/kg immediately after patient intubation. ICG was i.v. injected in bolus on demand of the operating surgeon at a dose of 12.5mg. No side-effects related to simultaneous injection of SF and ICG were identified. In all three cases, the use of SF allowed to better visualize the tumor areas during surgical removal, thus leading to a radical resection until no macroscopic appearance of residual tumor mass and no fluorescence was visible in the surgical cavity. ICG videoangiography confirmed the patency of branches of internal carotid artery after clipping of an unexpected small PComA aneurysm found

  18. Laser-assisted indocyanine green dye angiography accurately predicts the split-thickness graft timing of integra artificial dermis.

    Science.gov (United States)

    Fourman, Mitchell S; Phillips, Brett T; Fritz, Jason R; Conkling, Nicole; McClain, Steve A; Simon, Marcia; Dagum, Alexander B

    2014-08-01

    The use of an artificial dermal substitute such as Integra-a bilaminate combination of thin silicone and cross-linked bovine tendon collagen and chondroitin-6-sulfate-has become a popular method to address large surface area wounds or smaller, complex wounds devoid of a vascular bed. The incorporation of Integra depends on a vascular wound bed or periphery and can take 4 weeks or longer to occur. If the Integra has not fully incorporated at the time of placement of the split-thickness graft, complete graft loss may result. The availability of a minimally invasive method to assess the incorporation of Integra would be of great value. Two 5 × 10-cm paraspinal full-thickness wounds were created on 3 female swine. Wounds were randomly assigned full-thickness skin graft or Integra (Plainsboro, NJ) treatment. Both types of grafts were placed after the application of fibrin glue (Tisseel, Deerfield, Ill) to the wound bed. Laser Doppler imaging (LDI) (Moor), indocyanine green dye (ICG) angiography (LifeCell SPY), and clinical scoring were performed weekly for a period of 8 weeks after grafting. At 4 weeks, the silicone layer of the Integra was removed, and a culture of autologous keratinocytes was applied. A 4-mm punch biopsy sample of each graft was taken 1, 2, 4, 6, 7, and 8 weeks postoperatively for histologic analysis. Both ICG angiography and LDI perfusion measurements noted an increase in perfusion at the Integra graft site that peaked 3 weeks after grafting, corresponding with the start of neovascularization and the optimal time for the application of a split-thickness skin graft. indocyanine green dye angiography measurements exhibit greater reproducibility between animals at late time points as compared with LDI. This decrease in LDI precision is directly related to increases in scar tissue thickness of greater than 5 mm as determined via histologic analysis and corresponds with the accepted maximum penetration depth of the LDI laser. Indocyanine green dye

  19. Intraoperative indocyanine green fluorescent angiography-assisted modified superior gluteal artery perforator flap for reconstruction of sacral pressure sores.

    Science.gov (United States)

    Chang, Chun-Kai; Wu, Chien-Ju; Chen, Chun-Yu; Wang, Chi-Yu; Chu, Tzi-Shiang; Hsu, Kuo-Feng; Chiu, Han-Ting; Liu, Hung-Hui; Chou, Chang-Yi; Wang, Chih-Hsin; Lin, Chin-Ta; Dai, Niann-Tzyy; Tzeng, Yuan-Sheng

    2017-12-01

    Pressure sores are often observed in patients who are bedridden. They can be a severe problem not only for patients and their caregivers but also for plastic surgeons. Here, we describe a new method of superior gluteal artery perforator flap harvesting and anchoring with the assistance of intraoperative indocyanine green fluorescent angiography. In this report, we describe the procedure and outcomes for 19 patients with grades III and IV sacral pressure sores who underwent the operation between September 2015 and November 2016. All flaps survived, and two experienced wound-edge partial dehiscence. With the assistance of this imaging device, we were able to acquire a reliable superior gluteal artery perforator flap and perform modified operations with it that are safe, easy to learn and associated with fewer complications than are traditional. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  20. infrared spectrophotometer for simultaneous detection of traces of heavy water and indocyanine green in flowing blood. In vivo experimentation

    International Nuclear Information System (INIS)

    Capitini, R.; Roveyaz, P.

    1981-07-01

    We have developed an infrared absorption method for the pulmonary extravascular water and cardiac output determination by the multiple indicator technique. This led us to construct an original double differential spectrophotometer (DUPLEX) for simultaneous detection of traces of heavy water (D 2 O) and indocyanine green (ICG) in circulating blood in a single absorption cell. This DUPLEX is connected to a computer and results are treated on line. D 2 O and ICG are used as non toxic diffusible and vascular tracers respectively. Performances of the DUPLEX are given and show a high accuracy with D 2 O (x 10) and ICG (x 2) compared with the commercial optical analysers. We show the validity of the method for determining the cardiac output and the pulmonary extravascular water in the course of numerous experiments on human and rats subjects. Preliminary results concerning the measurement of global water on rats are also given [fr

  1. New technique for laryngotracheal mucosa transplantation. 'Stamp' welding using indocyanine green dye and albumin interaction with diode laser.

    Science.gov (United States)

    Wang, Z; Pankratov, M M; Gleich, L L; Rebeiz, E E; Shapshay, S M

    1995-07-01

    To investigate (1) the possibility of survival of free mucosa "stamp" grafts fixed in the airway with a new technique using indocyanine green-dyed albumin solder activated with a diode laser and (2) the degree of improvement of wound healing in the airway by applying modified microskin transplantation techniques from burn surgery to cover a relatively large wound with a few small pieces of mucosa anchored in place with the previously mentioned technique. Three (one control and two experimental) rectangular (10 x 8 mm) wounds in tracheal mucosa were produced in four experimental animals (dogs) using a carbon dioxide laser. The control wound was left uncovered. In the first experimental wound, a mucosal flap was raised and then fixed in place by a trapdoor flap method. In the second experimental wound, two small (each 2 x 3 mm) autogenous mucosa grafts were anchored onto the surface with indocyanine green-dyed albumin activated with an 810-nm diode laser. Histomorphologically, the postoperative results from three wounds were compared. The experimental wounds were completely covered by regenerated squamous cells in 1 week and by ciliated epithelium in 2 weeks after the operation despite the discrepancy in size of the graft to wound area (1:6.7) covered with the stamp mucosa. No thermal damage from the diode laser was noted in the second experimental wounds. In the control wounds, no coverage was observed at 1 week, and only squamous cells were noted 2 weeks postoperatively. All the wounds had normal ciliated epithelium coverage at 4 weeks. Transplanted stamp grafts provided similar or better healing than trapdoor flap transplants. This new technique made endoscopic mucosal grafting possible and offers a potential breakthrough in the management of laryngotracheal stenosis.

  2. Blood flow index using near-infrared spectroscopy and indocyanine green as a minimally invasive tool to assess respiratory muscle blood flow in humans

    DEFF Research Database (Denmark)

    Guenette, Jordan A; Henderson, William R; Dominelli, Paolo B

    2011-01-01

    Near-infrared spectroscopy (NIRS) in combination with indocyanine green (ICG) dye has recently been used to measure respiratory muscle blood flow (RMBF) in humans. This method is based on the Fick principle and is determined by measuring ICG in the respiratory muscles using transcutaneous NIRS...... relationships with the work of breathing and EMG for both respiratory muscles. The coefficients of determination (R(2)) comparing BFI vs. the work of breathing for the intercostal and sternocleidomastoid muscles were 0.887 (P

  3. Effect of ranibizumab on high-speed indocyanine green angiography and minimum intensity projection optical coherence tomography findings in neovascular age-related macular degeneration.

    Science.gov (United States)

    Nicholson, Benjamin P; Nigam, Divya; Toy, Brian; Stetson, Paul F; Agrón, Elvira; Jacobs-El, Naima; Cunningham, Denise; Cukras, Catherine; Wong, Wai; Wiley, Henry; Chew, Emily; Ferris, Frederick; Meyerle, Catherine B

    2015-01-01

    The purpose of this 1-year prospective study was to investigate how induction/pro re nata ranibizumab intravitreal treatment of eyes with neovascular age-related macular degeneration affects the anatomy of choroidal neovascularization (CNV) and the overlying outer retinal tissue. High-speed indocyanine green (HS-ICG) angiography measurements provided quantification of the CNV size in 60 patients followed for 1 year. Minimum intensity projection optical coherence tomography (MinIP OCT), a novel algorithm assessing minimum optical intensity between the internal limiting membrane and retinal pigment epithelium, measured the area of outer retinal disruption overlying the CNV. Fluorescein angiography was also assessed to evaluate late retinal leakage. After 1 year, the mean area of CNV measured with indocyanine green angiography decreased by 5.8%. The mean area of MinIP OCT of outer retinal disruption overlying the CNV decreased by 4.2%. Mean area of fluorescein angiography leakage decreased by 6.3%. Both the area of outer retinal disruption measured with MinIP OCT and the area of leakage on fluorescein angiography typically exceeded the area of CNV on indocyanine green angiography at baseline and 1 year. Choroidal neovascularization treated with induction/pro re nata intravitreal ranibizumab for 1 year essentially remained static. Minimum intensity projection optical coherence tomography suggests that the area of outer retinal disruption overlying the CNV may be greater than the CNV itself and often correlates with the leakage area on fluorescein angiography. Additionally, there was minimal change in the area of outer retinal disruption on MinIP OCT even when fluid resolved. Measurements of the extent of CNV lesions based on indocyanine green angiography and MinIP OCT may provide useful outcome variables to help assess the CNV complex longitudinally and warrant further validation.

  4. Indocyanine Green-Loaded Polydopamine-Reduced Graphene Oxide Nanocomposites with Amplifying Photoacoustic and Photothermal Effects for Cancer Theranostics.

    Science.gov (United States)

    Hu, Dehong; Zhang, Jingnan; Gao, Guanhui; Sheng, Zonghai; Cui, Haodong; Cai, Lintao

    2016-01-01

    Photoacoustic (PA) imaging and photothermal therapy (PTT) as light-induced theranostic platforms have been attracted much attention in recent years. However, the development of highly efficient and integrated phototheranostic nanoagents for amplifying PA imaging and PTT treatments poses great challenges. Here, we report a novel phototheranostic nanoagent using indocyanine green-loaded polydopamine-reduced graphene oxide nanocomposites (ICG-PDA-rGO) with amplifying PA and PTT effects for cancer theranostics. The results demonstrate that the PDA layer coating on the surface of rGO could effectively absorb a large number of ICG molecules, quench ICG's fluorescence, and enhance the PDA-rGO's optical absorption at 780 nm. The obtained ICG-PDA-rGO exhibits stronger PTT effect and higher PA contrast than that of pure GO and PDA-rGO. After PA imaging-guided PTT treatments, the tumors in 4T1 breast subcutaneous and orthotopic mice models are suppressed completely and no treatment-induced toxicity being observed. It illustrates that the ICG-PDA-rGO nanocomposites constitute a new class of theranostic nanomedicine for amplifying PA imaging and PTT treatments.

  5. Use of invisible near infrared light fluorescence with indocyanine green and methylene blue in urology. Part 2.

    Science.gov (United States)

    Polom, Wojciech; Markuszewski, Marcin; Rho, Young Soo; Matuszewski, Marcin

    2014-01-01

    In the second part of this paper, concerning the use of invisible near infrared light (NIR) fluorescence with indocyanine green (ICG) and methylene blue (MB) in urology, other possible uses of this new technique will be presented. In kidney transplantation, this concerns allograft perfusion and real time NIR-guided angiography; moreover, perfusion angiography of tissue flaps, NIRF visualization of ureters, NIR-guided visualization of urinary calcifications, NIRF in male infertility and semen quality assessment. In this part, we have also analysed cancer targeting and imaging fluorophores as well as cost benefits associated with the use of these new techniques. PubMed and Medline databases were searched for ICG and MB use in urological settings, along with data published in abstracts of urological conferences. Although NIR-guided ICG and MB are still in their initial phases, there have been significant developments in a few more major domains of urology, including 1) kidney transplantation: kidney allograft perfusion and vessel reconstruction; 2) angiography perfusion of tissue flaps; 3) visualization of ureters; 4) visualization of urinary calcifications; and 5) NIRF in male infertility and semen quality assessment. Near infrared technology in urology is at its early stages. More studies are needed to assess the true potential and limitations of the technology. Initial studies show that this pioneering tool may influence various aspects of urology.

  6. Preliminary study of laser welding for aortic dissection in a porcine model using a diode laser with indocyanine green.

    Science.gov (United States)

    Fujita, Masanori; Morimoto, Yuji; Ohmori, Sayaka; Usami, Noriko; Arai, Tsunenori; Maehara, Tadaaki; Kikuchi, Makoto

    2003-01-01

    The objective of this study was to determine whether a dissected aorta could be welded by a diode laser with a solder using an in vitro porcine aortic dissection model. Porcine aortic strips were dissected into two flaps and the dissected faces were immersed in a solution of indocyanine green. The two flaps were pressed at 0.2 kg/cm2 with contact between the two immersed faces. The pressed flaps were irradiated with a diode laser (810 nm) at intensities of 170-425 W/cm2 for 8 seconds. The welded flaps were studied by light microscopy and the adhesive strengths were measured. The irradiated flaps were successfully welded. The breaking stress, the maximum stress recorded in a stress-strain curve, increased with increase in irradiation intensity up to 396 W/cm2 (2.7 x 10(2) mmHg) and decreased when the intensity reached 425 W/cm2. In the specimen irradiated at 396 W/cm2, the welded faces showed continuous fusion of elastin layers, while some voids were seen between the welded faces in the specimen irradiated at 425 W/cm2. The dissected porcine aortas were successfully welded using a laser with solder. The results suggest that the welded aorta can bear physiological blood pressure. Copyright 2003 Wiley-Liss, Inc.

  7. Detection of posterior vortex veins in eyes with pathologic myopia by ultra-widefield indocyanine green angiography.

    Science.gov (United States)

    Moriyama, Muka; Cao, Kejia; Ogata, Satoko; Ohno-Matsui, Kyoko

    2017-09-01

    To analyse the characteristics of posterior vortex veins detected in highly myopic eyes by wide-field indocyanine green angiography (ICGA). One hundred and fifty-eight consecutive patients (302 eyes) with high myopia (myopic refractive error >8.0 dioptres (D) or axial length ≥26.5 mm) were studied. Wide-field ICGA was performed with the Spectralis HRA module. Posterior vortex veins were found in 80 eyes (26%). The prevalence of posterior staphyloma was significantly higher in eyes in which posterior vortex vein was detected than in eyes without posterior vortex vein. The posterior vortex veins were classified into five types according to the site of exit from the eye; around the optic nerve in 28%, in the macular area in 17%, along the border of staphyloma in 6%, along the margin of macular atrophy or large peripapillary conus in 21%, and elsewhere in 28%. In one eye, two posterior vortex veins collected the choroidal venous blood from the entire fundus. Wide-field ICGA can analyse the characteristic features of choroidal blood outflow system through posterior vortex veins in highly myopic eyes. They may play an important role as routes of choroidal outflow in highly myopic eyes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Comparison of indocyanine green fluorescence and parathyroid autofluorescence imaging in the identification of parathyroid glands during thyroidectomy.

    Science.gov (United States)

    Kahramangil, Bora; Berber, Eren

    2017-12-01

    Indocyanine green fluorescence (ICGF) and parathyroid autofluorescence (AF) are two new techniques that aid in the identification of parathyroid glands (PG) intraoperatively during thyroidectomy. There is no study comparing the efficacy of these techniques. This was an IRB-approved clinical study comparing the utility of ICGF and AF for identification of PGs during thyroidectomy. Data were collected prospectively. Both techniques were compared to naked eye (NE) for PG detection. Standard statistical methods were used for data analysis. Twenty-two patients in each group underwent a total of 39 total thyroidectomies and 5 thyroid lobectomies. AF and ICGF had similar detection rates for PGs [98% (61 of 62) and 95% (60 of 63) of PGs, respectively; P=0.31]. The location of PGs was suggested before detection with NE more frequently by AF than ICGF [52% (32 of 62) vs. 6% (4 of 63) of PGs; P0.99]. To the best of our knowledge, this is the first comparative study between parathyroid AF and ICGF in detection of PGs during thyroidectomy. Our data suggest both techniques have similarly high detection rates and that the main difference lies in the timing of detection. AF more frequently detects PGs before recognition with NE compared to ICGF.

  9. A novel duct-lobular segmentectomy for breast tumors with nipple discharge using near-infrared indocyanine green fluorescence imaging

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Ohno

    2013-10-01

    Full Text Available A 44-year-old woman was referred to our hospital with pathological nipple discharge from her left breast. Ultrasonography revealed a solid tumor beneath her left areola that measured 17 mm in diameter with a dilated mammary duct. Contrast-enhanced magnetic resonance imaging showed an early-enhanced cystic tumor and a dilated mammary duct. We performed a duct-lobular segmentectomy using near-infrared indocyanine green (ICG-fluorescence imaging. Under general anesthesia, a silicone tube was inserted into an orifice of a fluid-discharging mammary duct, and 1 mL dye-fluorescence liquid containing ICG and indigo carmine was injected into the mammary duct. A periareolar incision was made, and the fluorescence image of the demarcated mammary duct segment was obtained. The mammary duct segment was dissected, along with the demarcation line. The cystic lesion and dilated mammary duct were fully resected, and the pathological diagnosis was intraductal papilloma of the breast. We report that near-infrared ICG fluorescence could be applied for imaging of the mammary duct segment, and the fluorescence image allowed for easier duct-lobular segmentectomy for nipple discharge.

  10. 1,213 Cases of Treatment of Facial Acne Using Indocyanine Green and Intense Pulsed Light in Asian Skin

    Directory of Open Access Journals (Sweden)

    Kui Young Park

    2015-01-01

    Full Text Available Background. Photodynamic therapy (PDT has been used for acne, with various combinations of photosensitizers and light sources. Objective. We evaluated the effectiveness and safety of indocyanine green (ICG and intense pulsed light (IPL in the treatment of acne. Materials and Methods. A total of 1,213 patients with facial acne were retrospectively reviewed. Patients received three or five treatments of ICG and IPL at two-week intervals. Clinical response to treatment was assessed by comparing pre- and posttreatment clinical photographs and patient satisfaction scores. Results. Marked to excellent improvement was noted in 483 of 1,213 (39.8% patients, while minimal to moderate improvement was achieved in the remaining 730 (60.2% patients. Patient satisfaction scores revealed that 197 (16.3% of 1,213 patients were highly satisfied, 887 (73.1% were somewhat satisfied, and 129 (10.6% were unsatisfied. There were no significant side effects. Conclusion. These results suggest that PDT with ICG and IPL can be effectively and safely used in the treatment of acne.

  11. Indocyanine Green Angiographic and Multifocal Electroretinographic Features in the Diffuse and Regional Form of Bietti′s Crystalline Retinopathy

    Institute of Scientific and Technical Information of China (English)

    Libin Jiang; Feng Wen; Lezheng Wu; Hong Yan; Shixing Hu

    2002-01-01

    Prpose: To observe different features of indocyanine green angiography(ICGA) andtifocal electroretinography (ERG) in the diffuse and regional type of Bieti′sc stalline retinopathy (BCR). Thods: ICGA and the multifocal ERG were performed in two cases of the diffuse andregional type of BCR respectively. These data were compared with fluoresceinangiography (FA), standard Ganzfeld ERG, and visual field testing. Results: In the regional case, ICGA revealed reduced perfusion of the choroidalcirculation in the early phase and multiple hypofluorescent spots in the posterior pole in the late phase, due to choriocapillaris filling defect; the extent of choroiocapillaris losswas shown in early phase of ICGA and there were multifocal hyperfluorescent dotssurrounding hypofluorescent spots in late phase in the diffuse case. The multifocal ERGshowed that the central responses were markedly depressed, corresponding to the visualfield defects, while the findings of Ganzfeld ERG were normal in the regional BCR;however, both the multifocal ERG and Ganzfeld ERG were severely subnormal in thediffuse case.Conclusions: The features of ICGA and multifocal ERG are different between the diffuseand regional BCR. In the meantime, the two tools are also useful to differentiate the typeand assess the extentof evolution in BCR.

  12. Management of peripheral polypoidal choroidal vasculopathy with intravitreal bevacizumab and indocyanine green angiography-guided laser photocoagulation

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2012-01-01

    Full Text Available A 69-year-old lady presented with complaints of decreased vision in left eye since one month. Best Corrected Visual Acuity (BCVA was 6/18 in that eye. Fundus examination revealed non-central geographic atrophy and soft drusens at macula in both eyes. Temporal periphery of left eye revealed subretinal exudates with altered sub-RPE hemorrhage mimicking peripheral exudative hemorrhagic chorioretinopathy (PEHCR. Fundus Fluorescein Angiogram showed window defects at macula and blocked fluorescence at temporal periphery in left eye. However, Indocyanine green angiography (ICGA revealed active peripheral choroidal polyps. The patient was successfully treated with intravitreal bevacizumab and ICGA-guided laser photocoagulation. 27 months after laser treatment, BCVA improved to 6/9. Rationale of consecutive anti-vascular endothelial growth factor (VEGF treatment followed by more definitive laser photocoagulation is that anti-VEGF aids in resolution of subretinal fluid, thus making the polyp more amenable to focal laser photocoagulation which stabilizes the choroidal vasculature and prevents further leakage.

  13. Assessing pharmacokinetics of indocyanine green-loaded nanoparticle in tumor with a dynamic diffuse fluorescence tomography system

    Science.gov (United States)

    Zhang, Yanqi; Yin, Guoyan; Zhao, Huijuan; Ma, Wenjuan; Gao, Feng; Zhang, Limin

    2018-02-01

    Real-time and continuous monitoring of drug release in vivo is an important task in pharmaceutical development. Here, we devoted to explore a real-time continuous study of the pharmacokinetics of free indocyanine green (ICG) and ICG loaded in the shell-sheddable nanoparticles in tumor based on a dynamic diffuse fluorescence tomography (DFT) system: A highly-sensitive dynamic DFT system of CT-scanning mode generates informative and instantaneous sampling datasets; An analysis procedure extracts the pharmacokinetic parameters from the reconstructed time curves of the mean ICG concentration in tumor, using the Gauss-Newton scheme based on two-compartment model. Compared with the pharmacokinetic parameters of free ICG in tumor, the ICG loaded in the shell-sheddable nanoparticles shows efficient accumulation in tumor. The results demonstrate our proposed dynamic-DFT can provide an integrated and continuous view of the drug delivery of the injected agents in different formulations, which is helpful for the development of diagnosis and therapy for tumors.

  14. Utility of Indocyanine Green Video Angiography for Sylvian Fissure Dissection in Subarachnoid Hemorrhage Patients - Sylvian ICG Technique.

    Science.gov (United States)

    Toi, Hiroyuki; Matsushita, Nobuhisa; Ogawa, Yukari; Kinoshita, Keita; Satoh, Kohei; Takai, Hiroki; Hirai, Satoshi; Hara, Keijiro; Matsubara, Shunji; Uno, Masaaki

    2018-02-15

    Indocyanine green (ICG) emits fluorescence in the far-red domain under light excitation. ICG video angiography (ICG-VA) has been established as a useful method to evaluate blood flow in the operative field. We report the usefulness of ICG-VA for Sylvian fissure dissection in patients with subarachnoid hemorrhage (SAH). Subjects comprised 7 patients who underwent ICG-VA before opening the Sylvian fissure during neck clipping for ruptured cerebral aneurysm. We observed contrasted Sylvian veins before opening the Sylvian fissure using surgical microscopes. This procedure was termed "Sylvian ICG". We observed ICG fluorescence quickly in all cases. Sylvian veins that appeared unclear in the standard microscopic operative field covered with subarachnoid hemorrhage were extremely clearly depicted. These Sylvian ICG findings were helpful in identifying entry points and the dissecting course of the Sylvian fissure. At the time of clipping, no residual fluorescence from Sylvian ICG was present, and aneurysm clipping was not impeded. Sylvian ICG for SAH patients is a novel technique to facilitate dissection of the Sylvian fissure. We believe that this technique will contribute to improved safety of clipping surgery for ruptured aneurysms.

  15. Effects of nanoencapsulation and PEGylation on biodistribution of indocyanine green in healthy mice: quantitative fluorescence imaging and analysis of organs

    Directory of Open Access Journals (Sweden)

    Bahmani B

    2013-04-01

    Full Text Available Baharak Bahmani,1 Christian Y Lytle,2 Ameae M Walker,2 Sharad Gupta,1 Valentine I Vullev,1 Bahman Anvari1 1Department of Bioengineering, 2Division of Biomedical Sciences, University of California, Riverside, CA, USA Abstract: Near-infrared nanoconstructs present a potentially effective platform for site-specific and deep tissue optical imaging and phototherapy. We have engineered a polymeric nanocapsule composed of polyallylamine hydrochloride (PAH chains cross-linked with sodium phosphate and doped with indocyanine green (ICG toward such endeavors. The ICG-doped nanocapsules were coated covalently with polyethylene glycol (5000 daltons through reductive amination. We administrated the constructs by tail vein injection to healthy mice. To characterize the biodistribution of the constructs, we performed in vivo quantitative fluorescence imaging and subsequently analyzed the various extracted organs. Our results suggest that encapsulation of ICG in these PEGylated constructs is an effective approach to prolong the circulation time of ICG and delay its hepatic accumulation. Increased bioavailability of ICG, due to encapsulation, offers the potential of extending the clinical applications of ICG, which are currently limited due to rapid elimination of ICG from the vasculature. Our results also indicate that PAH and ICG-doped nanocapsules (ICG-NCs are not cytotoxic at the levels used in this study. Keywords: cancer, fluorescent imaging, nanoprobes, near infrared, pharmacokinetics, phototherapy, vascular imaging

  16. Indocyanine Green Videoangiography for Surgery of a Ruptured Dissecting Aneurysm in the Precommunicating Anterior Cerebral Artery: A Technical Case Report.

    Science.gov (United States)

    Nagai, Yasunori; Goto, Masanori; Toda, Hiroki; Nishida, Namiko; Yoshimoto, Naoya; Iwasaki, Koichi

    2017-08-01

    Indocyanine green videoangiography (ICG-VA) is an important intraoperative adjunct for saccular aneurysm surgery, but its efficacy in surgery for dissecting aneurysms has rarely been reported. The authors describe the usefulness of preclipping ICG-VA in a rare case of a ruptured dissecting aneurysm located at the precommunicating (A1) segment of the anterior cerebral artery. A 52-year-old woman, with no history of connective tissue diseases or vascular disorders, presented with sudden headache and convulsion. The CT scan showed that the patient had subarachnoid hemorrhage. Angiography showed a dissecting aneurysm in the left A1 segment of the anterior cerebral artery. Thus, the patient underwent trapping of the dissecting aneurysm. ICG-VA was used as an intraoperative adjunct before and after clipping. The preclipping ICG-VA showed the heterogeneously bright dissecting aneurysm and branching arteries even in the presence of hematoma. Preclipping ICG-VA may enhance the advantage of direct surgery for dissecting aneurysm by allowing visualization of the extent of the dissected vascular wall and the related branching arteries. ICG-VA can be an indispensable adjunct to minimize the compromise from the surgical treatment for intracranial dissecting aneurysms. Copyright © 2017 by the Congress of Neurological Surgeons

  17. Multiwavelength time-resolved detection of fluorescence during the inflow of indocyanine green into the adult's brain

    Science.gov (United States)

    Gerega, Anna; Milej, Daniel; Weigl, Wojciech; Botwicz, Marcin; Zolek, Norbert; Kacprzak, Michal; Wierzejski, Wojciech; Toczylowska, Beata; Mayzner-Zawadzka, Ewa; Maniewski, Roman; Liebert, Adam

    2012-08-01

    Optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for clinical assessment of brain perfusion in adults at the bedside. Methodology of multiwavelength and time-resolved detection of fluorescence light excited in the ICG is presented and advantages of measurements at multiple wavelengths are discussed. Measurements were carried out: 1. on a physical homogeneous phantom to study the concentration dependence of the fluorescence signal, 2. on the phantom to simulate the dynamic inflow of ICG at different depths, and 3. in vivo on surface of the human head. Pattern of inflow and washout of ICG in the head of healthy volunteers after intravenous injection of the dye was observed for the first time with time-resolved instrumentation at multiple emission wavelengths. The multiwavelength detection of fluorescence signal confirms that at longer emission wavelengths, probability of reabsorption of the fluorescence light by the dye itself is reduced. Considering different light penetration depths at different wavelengths, and the pronounced reabsorption at longer wavelengths, the time-resolved multiwavelength technique may be useful in signal decomposition, leading to evaluation of extra- and intracerebral components of the measured signals.

  18. Prefabricated Cervical Skin Flaps for Hemi-Facial Resurfacing: Elucidating the Natural History of Postoperative Edema Using Indocyanine Green.

    Science.gov (United States)

    Li, Ke; Min, Peiru; Sadigh, Parviz; Grassetti, Luca; Lazzeri, Davide; Torresetti, Matteo; Marsili, Riccardo; Feng, Shaoqing; Liu, Ningfei; Zhang, Yi Xin

    2018-02-01

    The increases in capillary wall permeability and capillary hydrostatic pressure are considered to be the causes for the acute swelling seen in flaps; however, disruption of the circulating flap lymphatics could be another contributory factor. In this study we monitor the development of flap edema in a series of 18 prefabricated flaps and aim to delineate the natural history of this phenomenon by use of lymphography. Postoperative swelling was monitored in a series of 18 pre-expanded prefabricated cervical skin flaps used for hemi-facial burns-scar resurfacing. Time to spontaneous resolution, presence or absence of venous congestion, and clinical outcome were recorded. In two cases, indocyanine-green (ICG) lymphography was used to monitor the dermal backflow pattern until swelling had completely resolved. Average moving velocity of ICG after injection as well as flap thickness was also recorded over the follow-up period. The average moving velocity of ICG in the flap lymphatics improved from 0.48 cm/min to 1.5 cm/min in the first 12 days after flap transfer. The dermal backflow pattern was stardust in the first 12 days, indicating moderate lymphedema, transforming to splash from week three, and a robust collecting lymphatic vessel occurring from the fifth month, indicating mild lymphedema and lymphatic channel recovery, respectively. Transient swelling was observed in all prefabricated flaps in our series. We postulate that this is mostly secondary to lymphatic disruption that subsides as lymphangiogenesis takes place. ICG lymphography is an inexpensive, safe, and easy-to-use imaging technology that could be used in the monitoring of postoperative lymphedema seen in prefabricated flaps.

  19. Near-infrared fluorescence imaging and photodynamic therapy with indocyanine green lactosome has antineoplastic effects for hepatocellular carcinoma.

    Directory of Open Access Journals (Sweden)

    Takumi Tsuda

    Full Text Available Anticancer agents and operating procedures have been developed for hepatocellular carcinoma (HCC patients, but their prognosis remains poor. It is necessary to develop novel diagnostic and therapeutic strategies for HCC to improve its prognosis. Lactosome is a core-shell-type polymeric micelle, and enclosing labeling or anticancer agents into this micelle enables drug delivery. In this study, we investigated the diagnostic and therapeutic efficacies of indocyanine green (ICG-loaded lactosome for near-infrared fluorescence (NIF imaging and photodynamic therapy (PDT for HCC.The human HCC cell line HuH-7 was treated with ICG or ICG-lactosome, followed by PDT, and the cell viabilities were measured (in vitro PDT efficiency. For NIF imaging, HuH-7 cells were subcutaneously transplanted into BALB/c nude mice, followed by intravenous administration of ICG or ICG-lactosome. The transplanted animals were treated with PDT, and the antineoplastic effects were analyzed (in vivo PDT efficiency.PDT had toxic effects on HuH-7 cells treated with ICG-lactosome, but not ICG alone. NIF imaging revealed that the fluorescence of tumor areas in ICG-lactosome-treated animals was higher than that of contralateral regions at 24 h after injection and thereafter. PDT exerted immediate and continuous phototoxic effects in the transplanted mice treated with ICG-lactosome.Our results demonstrate that ICG-lactosome accumulated in xenograft tumors, and that PDT had antineoplastic effects on these malignant implants. NIF imaging and PDT with ICG-lactosome could be useful diagnostic and/or therapeutic strategies for HCC.

  20. Intraoperative use of indocyanine green angiography for selecting the more reliable perforator of the anterolateral thigh flap: A comparison study.

    Science.gov (United States)

    La Padula, Simone; Hersant, Barbara; Meningaud, Jean Paul

    2018-03-30

    Anatomical variability of anterolateral thigh flap (ALT) perforators has been reported. The aim of this study is to assess if the use of intraoperative indocyanine green angiography (iICGA) can help surgeons to choose the ALT flap best perforator to be preserved. A retrospective study was conducted in 28 patients with open tibial fracture, following a road traffic crash, who had undergone ALT flap. Patients were classified into two groups: ICGA group (iICGA was used to select the more reliable perforator) and control group. The mean tissue loss size of the ICGA group (n = 13, 11 men and 2 women, mean age: 52 ± 6 years) was of 16.6 cm × 12.2 cm. The mean defect size of the control group (n = 15, 14 men and 1 women, mean age: 50 ± 5.52 years) was of 15.3 cm × 11.1 cm. Statistical analysis was performed to analyze and compare the results. ICGA allowed preserving only the most functional perforator, that provided the best ALT flap perfusion in 10 out of the 13 cases (77%). ICGA allowed a significant operative time reduction (160 ± 23 vs. 202 ± 48 minutes; P < .001). One case of distal necrosis was observed in the ICGA group (mean follow-up 12.3 months), while partial skin necrosis occurred in three cases of the control group (mean follow-up 13.1 months); P = .35. No additional coverage was required and a successful bone healing was observed in both groups. These findings suggest that iICGA is an effective method that allows to select the most reliable ALT flap perforators and to reduce operative time. © 2018 Wiley Periodicals, Inc.

  1. Pilot Assessment of the Repeatability of Indocyanine Green Fluorescence Imaging and Correlation with Traditional Foot Perfusion Assessments.

    Science.gov (United States)

    Venermo, M; Settembre, N; Albäck, A; Vikatmaa, P; Aho, P-S; Lepäntalo, M; Inoue, Y; Terasaki, H

    2016-10-01

    Ankle brachial index (ABI), toe pressures (TP), and transcutaneous oxygen pressure (TcPO 2 ) are traditionally used in the assessment of critical limb ischemia (CLI). Indocyanine green (ICG) fluorescence imaging can be used to evaluate local circulation in the foot and to evaluate the severity of ischemia. This prospective study analyzed the suitability of a fluorescence imaging system (photodynamic eye [PDE]) in CLI. Forty-one patients with CLI were included. Of the patients, 66% had diabetes and there was an ischemic tissue lesion in 70% of the limbs. ABI, toe pressures, TcPO 2 and ICG-fluorescence imaging (ICG-FI) were measured in each leg. To study the repeatability of the ICG-FI, each patient underwent the study twice. After the procedure, foot circulation was measured using a time-intensity curve, where T1/2 (the time needed to achieve half of the maximum fluorescence intensity) and PDE10 (increase of the intensity during the first 10 s) were determined. A time-intensity curve was plotted using the same areas as for the TcPO 2 probes (n=123). The mean ABI was 0.43, TP 21 mmHg, TcPO 2 23 mmHg, T1/2 38 s, and PDE10 19 AU. Time-intensity curves were repeatable. In a Bland-Altman scatter plot, the 95% limits of agreement of PDE10 was 9.9 AU and the corresponding value of T1/2 was 14 s. Correlation between ABI and TP was significant (R=.73, p<.001), and it was weaker in diabetic patients (R=.47, p=.048) compared with non-diabetic patients (R=.89, p=.002). Correlations between ABI and TcPO 2 and TP and TcPO 2 were weak (R=.37, p=.05 and R=.43, p=.037, respectively). Correlation between TcPO 2 and PDE10 was strong in diabetic patients (R=.70, p=.003). According to this pilot study, ICG-FI with PDE can be used in the assessment of blood supply in the ischemic foot. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Imaging of pharmacokinetic rates of indocyanine green in mouse liver with a hybrid fluorescence molecular tomography/x-ray computed tomography system.

    Science.gov (United States)

    Zhang, Guanglei; Liu, Fei; Zhang, Bin; He, Yun; Luo, Jianwen; Bai, Jing

    2013-04-01

    Pharmacokinetic rates have the potential to provide quantitative physiological and pathological information for biological studies and drug development. Fluorescence molecular tomography (FMT) is an attractive imaging tool for three-dimensionally resolving fluorophore distribution in small animals. In this letter, pharmacokinetic rates of indocyanine green (ICG) in mouse liver are imaged with a hybrid FMT and x-ray computed tomography (XCT) system. A recently developed FMT method using structural priors from an XCT system is adopted to improve the quality of FMT reconstruction. In the in vivo experiments, images of uptake and excretion rates of ICG in mouse liver are obtained, which can be used to quantitatively evaluate liver function. The accuracy of the results is validated by a fiber-based fluorescence measurement system.

  3. Indocyanine green labeled with /sup 123/I for dynamic studies of the hepato-biliary system. [/sup 131/I, /sup 125/I

    Energy Technology Data Exchange (ETDEWEB)

    Lambrecht, R.M.; Ansari, A.N.; Wolf, A.P.; Atkins, H.L.

    1975-01-01

    This report summarizes the results to develop an iodine-123 labeled agent for dynamic studies of the hepato-biliary system. Iodine-123 is an ideal nuclide for radiopharmaceuticals, because of its short half-life (T/sub /sup 1///sub 2// = 13.3 hr); its decay with a high abundance (83%) of 159 keV photons; and the reduced patient radiation exposure (a factor of 100 less than iodine-131). Indocyanine green, a tricarbanocyanine dye, was introduced by Heseltine and co-workers in 1956, has several characteristics which suggested that iodine-123 labeled ICG might be potentially useful for hepatic functional evaluation. The plasma clearance and biliary excretion kinetics of /sup 123/I-ICG (in dogs) will be compared to /sup 131/I-rose bengal and bromosulphalein labeled with iodine-125.

  4. Development of PLGA-lipid nanoparticles with covalently conjugated indocyanine green as a versatile nanoplatform for tumor-targeted imaging and drug delivery

    Directory of Open Access Journals (Sweden)

    Xin Y

    2016-11-01

    Full Text Available Yu Xin, Tie Liu, Chenlong Yang Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, People’s Republic of China Abstract: We have prepared novel poly(d,l-lactide-co-glycolide (PLGA lipid nanoparticles (PNPs that covalently conjugate folic acid (FA and indocyanine green (ICG, in addition to encapsulating resveratrol (RSV (FA-RSV/ICG-PLGA-lipid NPs, abbreviated as FA-RIPNPs; these nanoparticles have been developed for simultaneous targeted delivery of anticancer drug and fluorescence imaging. The FA-RIPNPs, with an average particle size of 92.8±2.1 nm, were prepared by a facile self-assembly-and-nanoprecipitation method, and they showed excellent stability and biocompatibility characteristics. The FA-RIPNPs exhibited an RSV encapsulation efficiency of approximately 65.6%±4.7% and a maximum release ratio of 78.2%±4.1% at pH 5.0 and 37°C. Confocal fluorescence images showed that FA-RIPNPs may facilitate a high cellular uptake via FA receptor-mediated endocytosis. Furthermore, FA-RIPNPs (containing 50 µg/mL RSV induced a 81.4%±2.1% U87 cell inhibition rate via apoptosis, a value that proved to be higher than what has been shown for free RSV (53.1%±1.1%, equivalent RSV concentration. With a formulated polyethylene glycol (PEG shell around the PLGA core, FA-RIPNPs prolonged the blood circulation of both free RSV and ICG, which approximately increased 6.96- and 39.4-fold (t1/2, respectively. Regarding FA-RIPNP use as a near-infrared probe, in vivo fluorescence images indicated a highly efficient accumulation of FA-RIPNPs in the tumor tissue, which proved to be approximately 2.8- and 12.6-fold higher than the RIPNPs and free ICG, respectively. Intravenous injection of FA-RIPNPs into U87 tumor-bearing mice demonstrated the best tumor inhibition effect for all tested drugs, including free RSV and RIPNPs, with no relapse, showing high biocompatibility and with no significant systemic in vivo toxicity over the

  5. Real-time navigation system for sentinel lymph node biopsy in breast cancer patients using projection mapping with indocyanine green fluorescence.

    Science.gov (United States)

    Takada, Masahiro; Takeuchi, Megumi; Suzuki, Eiji; Sato, Fumiaki; Matsumoto, Yoshiaki; Torii, Masae; Kawaguchi-Sakita, Nobuko; Nishino, Hiroto; Seo, Satoru; Hatano, Etsuro; Toi, Masakazu

    2018-05-09

    Inability to visualize indocyanine green fluorescence images in the surgical field limits the application of current near-infrared fluorescence imaging (NIR) systems for real-time navigation during sentinel lymph node (SLN) biopsy in breast cancer patients. The aim of this study was to evaluate the usefulness of the Medical Imaging Projection System (MIPS), which uses active projection mapping, for SLN biopsy. A total of 56 patients (59 procedures) underwent SLN biopsy using the MIPS between March 2016 and November 2017. After SLN biopsy using the MIPS, residual SLNs were removed using a conventional NIR camera and/or radioisotope method. The primary endpoint of this study was identification rate of SLNs using the MIPS. In all procedures, at least one SLN was detected by the MIPS, giving an SLN identification rate of 100% [95% confidence interval (CI) 94-100%]. SLN biopsy was successfully performed without operating lights in all procedures. In total, 3 positive SLNs were excised using MIPS, but were not included in the additional SLNs excised by other methods. The median number of SLNs excised using the MIPS was 3 (range 1-7). Of procedures performed after preoperative systemic therapy, the median number of SLNs excised using the MIPS was 3 (range 2-6). The MIPS is effective in detecting SLNs in patients with breast cancer, providing continuous and accurate projection of fluorescence signals in the surgical field, without need for operating lights, and could be useful in real-time navigation surgery for SLN biopsy.

  6. Prussian blue/serum albumin/indocyanine green as a multifunctional nanotheranostic agent for bimodal imaging guided laser mediated combinatorial phototherapy.

    Science.gov (United States)

    Sahu, Abhishek; Lee, Jong Hyun; Lee, Hye Gyeong; Jeong, Yong Yeon; Tae, Giyoong

    2016-08-28

    Developing novel nanotheranostic agent using only clinically approved materials is highly desirable and challenging. In this study, we combined three clinically approved materials, Prussian blue (PB), serum albumin (BSA), and indocyanine green (ICG), by a simple and biocompatible method to prepare a multifunctional theranostic PB-BSA-ICG nanoparticle. The multifunctional nanoparticle system could provide dual mode magnetic resonance (MR) and near infrared (NIR) fluorescence imaging as well as combined photothermal and photodynamic (PTT-PDT) therapy in response to a single NIR laser. This nanoparticle showed an excellent stability in physiological solutions and could suppress the photo-instability of ICG. In the absence of light, the nanoparticles showed no cytotoxicity, but significant cell death was induced through combined PTT-PDT effect after irradiation with NIR laser light. A high tumor accumulation and minimal nonspecific uptake by other major organs of PB-BSA-ICG nanoparticle were observed in vivo, analyzed by T1-weighted MR and NIR fluorescence bimodal imaging in tumor xenograft mice after intravenous injection. The nanoparticles efficiently suppressed the tumor growth through combinatorial phototherapy with no tumor recurrence upon a single NIR laser irradiation. These results demonstrated that PB-BSA-ICG is potentially an interesting nanotheranostic agent for imaging guided cancer therapy by overcoming the limitations of each technology and enhancing the therapeutic efficiency as well as reducing side effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. A Near-Infrared Photothermal Effect-Responsive Drug Delivery System Based on Indocyanine Green and Doxorubicin-Loaded Polymeric Micelles Mediated by Reversible Diels-Alder Reaction.

    Science.gov (United States)

    Li, Hui; Li, Junjie; Ke, Wendong; Ge, Zhishen

    2015-10-01

    Near-infrared light (NIR) possesses great advantages for light-responsive controllable drug release, such as deep tissue penetration and low damage to healthy tissues. Herein, a NIR-responsive drug delivery system is developed based on a NIR dye, indocyanine green (ICG), and anticancer drug, doxorubicin (DOX)-loaded thermoresponsive block copolymer micelles, in which the drug release can be controlled via NIR irradiation. First, block copolymers, poly(oligo(ethylene glycol) methacrylate)-block-poly(furfuryl methacrylate) (POEGMA-b-PFMA), are synthesized by sequential reversible addition-fragmentation chain-transfer (RAFT) polymerization, followed by modification with N-octyl maleimide through Diels-Alder (DA) reaction to produce POEGMA-b-POMFMA. The self-assembly of POEGMA-b-POMFMA by nano-precipitation in aqueous solution affords the polymeric micelles which are used to simultaneously encapsulate ICG and DOX. Upon irradiation by NIR light (805 nm), the loaded DOX is released rapidly from the micelles due to partial retro DA reaction and local temperature increase-induced faster drug diffusion by the photothermal effect. Cytotoxicity evaluation and intracellular distribution observation demonstrate significant synergistic effects of NIR-triggered drug release, photothermal, and chemotherapy toward cancer cells under NIR irradiation. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. The Predictive Value of Indocyanine Green Clearance in Future Liver Remnant for Posthepatectomy Liver Failure Following Hepatectomy with Extrahepatic Bile Duct Resection.

    Science.gov (United States)

    Yokoyama, Yukihiro; Ebata, Tomoki; Igami, Tsuyoshi; Sugawara, Gen; Mizuno, Takashi; Yamaguchi, Junpei; Nagino, Masato

    2016-06-01

    Postoperative liver failure (PHLF) is one of the most common complications following major hepatectomy. The preoperative assessment of future liver remnant (FLR) function is critical to predict the incidence of PHLF. To determine the efficacy of the plasma clearance rate of indocyanine green clearance of FLR (ICGK-F) in predicting PHLF in cases of highly invasive hepatectomy with extrahepatic bile duct resection. Five hundred and eighty-five patients who underwent major hepatectomy with extrahepatic bile duct resection, from 2002 to 2014 in a single institution, were evaluated. Among them, 192 patients (33 %) had PHLF. The predictive value of ICGK-F for PHLF was determined and compared with other risk factors for PHLF. The incidence of PHLF was inversely proportional to the level of ICGK-F. With multivariate logistic regression analysis, ICGK-F, combined pancreatoduodenectomy, the operation time, and blood loss were identified as independent risk factors of PHLF. The risk of PHLF increased according to the decrement of ICGK-F (the odds ratio of ICGK-F for each decrement of 0.01 was 1.22; 95 % confidence interval 1.12-1.33; P bile duct resection. This criterion may be useful for highly invasive hepatectomy, such as that with extrahepatic bile duct resection.

  9. Detection of peritoneal dissemination with near-infrared fluorescence laparoscopic imaging using a liposomal formulation of a synthesized indocyanine green liposomal derivative.

    Science.gov (United States)

    Hoshino, Isamu; Maruyama, Tetsuro; Fujito, Hiromichi; Tamura, Yutaka; Suganami, Akiko; Hayashi, Hideki; Toyota, Taro; Akutsu, Yasunori; Murakami, Kentaro; Isozaki, Yuka; Akanuma, Naoki; Takeshita, Nobuyoshi; Toyozumi, Takeshi; Komatsu, Aki; Matsubara, Hisahiro

    2015-03-01

    Although conventional staging laparoscopy (SL) has improved the diagnostic accuracy of peritoneal dissemination, novel technology is needed to increase the sensitivity of SL. We herein describe a new imaging method employing near-infrared (NIR) fluorescence imaging using a liposomal synthesized indocyanine green (ICG) liposomal derivative, LP-ICG-C18. LP-ICG-C18 is a NIR-photoactivating probe in which an ICG fluorophore is covalently conjugated with a phospholipid moiety. Nude mice were intraperitoneally injected with gastric cancer cells. Twelve days later, the mice were given intravenous injections of LP-ICG-C18 at a dose of 0.15 mg/kg. A NIR imaging system was used to identify the disseminated tumors. The disseminated nodules in mice were detected without any difficulties. Disseminated tumor nodules were collected from mice with or without injections of liposomal formulation and were transferred into the swine peritoneal cavity. The nodules in the swine peritoneal cavity were clearly and promptly defined by the NIR imaging system. NIR-fluorescing liposomal probes can effectively target peritoneal disseminated tumors and can be easily detected by a NIR imaging system. These results warrant future clinical trials of our imaging system and may contribute to a more precise diagnosis and therapeutic approach for gastric cancer patients. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  10. In silico identification of a therapeutic target for photo-activated disinfection with indocyanine green: Modeling and virtual screening analysis of Arg-gingipain from Porphyromonas gingivalis.

    Science.gov (United States)

    Pourhajibagher, Maryam; Bahador, Abbas

    2017-06-01

    Porphyromonas gingivalis is a momentous bacterial etiological agent associated with periodontitis, peri-implantitis as well as endodontic infections. The potential advantage of Photo-activated disinfection (PAD) as a promising novel approach is the choice of a suitable target site, specific photosensitizer, and wavelength of light for delivery of the light from source to target. Since Arg-gingipain is a cysteine proteinase that is involved in the virulence of P. gingivalis, it was evaluated as a target site for PAD with indocyanine green (ICG) as a photosensitizer. In this study, we used a range of in silico strategies, bioinformatics tools, biological databases, and computer simulation molecular modeling to evaluate the capacity of Arg-gingipain. The predicted structure of Arg-gingipain indicated that it is located outside the cell and has nine domains and 17 ligands, including two calcium ions and three sodium ions with positive charges which can be a site of interaction for anionic ICG. Based on the results of this study, anionic ICG desires to bind and interact with residues of Arg-gingipain during PAD as a main site to enhance the yield of treatment of endo-periodontal lesions. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Flash fluorescence with indocyanine green videoangiography to identify the recipient artery for bypass with distal middle cerebral artery aneurysms: operative technique.

    Science.gov (United States)

    Rodríguez-Hernández, Ana; Lawton, Michael T

    2012-06-01

    Distal middle cerebral artery (MCA) aneurysms frequently have nonsaccular morphology that necessitates trapping and bypass. Bypasses can be difficult because efferent arteries lie deep in the opercular cleft and may not be easily identifiable. We introduce the "flash fluorescence" technique, which uses videoangiography with indocyanine green (ICG) dye to identify an appropriate recipient artery on the cortical surface for the bypass, enabling a more superficial and easier anastomosis. Flash fluorescence requires 3 steps: (1) temporary clip occlusion of the involved afferent artery; (2) videoangiography demonstrating fluorescence in uninvolved arteries on the cortical surface; and (3) removal of the temporary clip with flash fluorescence in the involved efferent arteries on the cortical surface, thereby identifying a recipient. Alternatively, temporary clips can occlude uninvolved arteries, and videoangiography will demonstrate initial fluorescence in efferent arteries during temporary occlusion and flash fluorescence in uninvolved arteries during reperfusion. From a consecutive series of 604 MCA aneurysms treated microsurgically, 22 (3.6%) were distal aneurysms and 11 required a bypass. The flash fluorescence technique was used in 3 patients to select the recipient artery for 2 superficial temporal artery-to-MCA bypasses and 1 MCA-MCA bypass. The correct recipient was selected in all cases. The flash fluorescence technique provides quick, reliable localization of an appropriate recipient artery for bypass when revascularization is needed for a distal MCA aneurysm. This technique eliminates the need for extensive dissection of the efferent artery and enables a superficial recipient site that makes the anastomosis safer, faster, and less demanding.

  12. Cranial nerve contrast using nerve-specific fluorophores improved by paired-agent imaging with indocyanine green as a control agent

    Science.gov (United States)

    Torres, Veronica C.; Vuong, Victoria D.; Wilson, Todd; Wewel, Joshua; Byrne, Richard W.; Tichauer, Kenneth M.

    2017-09-01

    Nerve preservation during surgery is critical because damage can result in significant morbidity. This remains a challenge especially for skull base surgeries where cranial nerves (CNs) are involved because visualization and access are particularly poor in that location. We present a paired-agent imaging method to enhance identification of CNs using nerve-specific fluorophores. Two myelin-targeting imaging agents were evaluated, Oxazine 4 and Rhodamine 800, and coadministered with a control agent, indocyanine green, either intravenously or topically in rats. Fluorescence imaging was performed on excised brains ex vivo, and nerve contrast was evaluated via paired-agent ratiometric data analysis. Although contrast was improved among all experimental groups using paired-agent imaging compared to conventional, solely targeted imaging, Oxazine 4 applied directly exhibited the greatest enhancement, with a minimum 3 times improvement in CNs delineation. This work highlights the importance of accounting for nonspecific signal of targeted agents, and demonstrates that paired-agent imaging is one method capable of doing so. Although staining, rinsing, and imaging protocols need to be optimized, these findings serve as a demonstration for the potential use of paired-agent imaging to improve contrast of CNs, and consequently, surgical outcome.

  13. A Real-Time Near-Infrared Fluorescence Imaging Method for the Detection of Oral Cancers in Mice Using an Indocyanine Green-Labeled Podoplanin Antibody.

    Science.gov (United States)

    Ito, Akihiro; Ohta, Mitsuhiko; Kato, Yukinari; Inada, Shunko; Kato, Toshio; Nakata, Susumu; Yatabe, Yasushi; Goto, Mitsuo; Kaneda, Norio; Kurita, Kenichi; Nakanishi, Hayao; Yoshida, Kenji

    2018-01-01

    Podoplanin is distinctively overexpressed in oral squamous cell carcinoma than oral benign neoplasms and plays a crucial role in the pathogenesis and metastasis of oral squamous cell carcinoma but its diagnostic application is quite limited. Here, we report a new near-infrared fluorescence imaging method using an indocyanine green (ICG)-labeled anti-podoplanin antibody and a desktop/a handheld ICG detection device for the visualization of oral squamous cell carcinoma-xenografted tumors in nude mice. Both near-infrared imaging methods using a desktop (in vivo imaging system: IVIS) and a handheld device (photodynamic eye: PDE) successfully detected oral squamous cell carcinoma tumors in nude mice in a podoplanin expression-dependent manner with comparable sensitivity. Of these 2 devices, only near-infrared imaging methods using a handheld device visualized oral squamous cell carcinoma xenografts in mice in real time. Furthermore, near-infrared imaging methods using the handheld device (PDE) could detect smaller podoplanin-positive oral squamous cell carcinoma tumors than a non-near-infrared, autofluorescence-based imaging method. Based on these results, a near-infrared imaging method using an ICG-labeled anti-podoplanin antibody and a handheld detection device (PDE) allows the sensitive, semiquantitative, and real-time imaging of oral squamous cell carcinoma tumors and therefore represents a useful tool for the detection and subsequent monitoring of malignant oral neoplasms in both preclinical and some clinical settings.

  14. The use of indocyanine green lymphography for the treatment of postoperative chylothorax with lipiodol lymphangiography in a 2-year-old child

    Directory of Open Access Journals (Sweden)

    Motoi Kato

    2017-08-01

    Full Text Available Postoperative chylothorax in infants prolongs hospital stay and possibly causes developmental delay because of its conservative treatment including inanition. Several medical and surgical treatments may be applied, but none constitute the absolute solution. Treatment with lipiodol during lymphangiography for postoperative chylothorax has been reported to be highly effective and less invasive in adults. On the other hand, few cases have been reported in infants. We demonstrate successful blockage of chyle leakage with lipiodol injection through the inguinal lymph node in a 2-year-old infant. The patient had undergone on-pump coarctectomy and chylothorax developed soon after surgery. Several medical treatments were partially effective, but the chest tube could not be removed because sequential aspiration was required to maintain a normal respiratory status. With the patient under general anesthesia, lipiodol injection combined with indocyanine green (ICG lymphography was performed. Lymphography combined with ICG significantly contributed not only to intraoperative detection of the inguinal lymph nodes but also to postoperative early detection of lymphedema caused by this procedure. This procedure required a simple maneuver and is probably applicable to other cases of traumatic chylothorax, such as after surgeries on the esophagus, trachea, or other components of the posterior mediastinum.

  15. Dynamic infrared thermography (DIRT) for assessment of skin blood perfusion in cranioplasty: a proof of concept for qualitative comparison with the standard indocyanine green video angiography (ICGA).

    Science.gov (United States)

    Rathmann, P; Chalopin, C; Halama, D; Giri, P; Meixensberger, J; Lindner, D

    2018-03-01

    Complications in wound healing after neurosurgical operations occur often due to scarred dehiscence with skin blood perfusion disturbance. The standard imaging method for intraoperative skin perfusion assessment is the invasive indocyanine green video angiography (ICGA). The noninvasive dynamic infrared thermography (DIRT) is a promising alternative modality that was evaluated by comparison with ICGA. The study was carried out in two parts: (1) investigation of technical conditions for intraoperative use of DIRT for its comparison with ICGA, and (2) visual and quantitative comparison of both modalities in a proof of concept on nine patients. Time-temperature curves in DIRT and time-intensity curves in ICGA for defined regions of interest were analyzed. New perfusion parameters were defined in DIRT and compared with the usual perfusion parameters in ICGA. The visual observation of the image data in DIRT and ICGA showed that operation material, anatomical structures and skin perfusion are represented similarly in both modalities. Although the analysis of the curves and perfusion parameter values showed differences between patients, no complications were observed clinically. These differences were represented in DIRT and ICGA equivalently. DIRT has shown a great potential for intraoperative use, with several advantages over ICGA. The technique is passive, contactless and noninvasive. The practicability of the intraoperative recording of the same operation field section with ICGA and DIRT has been demonstrated. The promising results of this proof of concept provide a basis for a trial with a larger number of patients.

  16. Impact of Indocyanine Green Concentration, Exposure Time, and Degree of Dissolution in Creating Toxic Anterior Segment Syndrome: Evaluation in a Rabbit Model

    Directory of Open Access Journals (Sweden)

    Tamer Tandogan

    2016-01-01

    Full Text Available Purpose. To investigate the role of indocyanine green (ICG dye as a causative material of toxic anterior segment syndrome (TASS in an experimental rabbit model. Method. Eight eyes of four rabbits were allocated to this study. Capsular staining was performed using ICG dye, after which the anterior chamber was irrigated with a balanced salt solution. The effects of different concentrations (control, 0.25, 0.5, and 1.0%, exposure times (10 and 60 seconds, and the degree of dissolution (differently vortexed were investigated. The analysis involved anterior segment photography, ultrasound pachymetry, prostaglandin assay (PGE2 Parameter Assay, R&D systems, Inc., and scanning electron microscopy of each iris. Result. There was no reaction in the control eye. A higher aqueous level of PGE2 and more severe inflammatory reaction were observed in cases of eyes with higher concentration, longer exposure time, and poorly dissolved dye. Additionally, scanning electron microscopy revealed larger and coarser ICG particles. Conclusion. TASS occurrence may be associated with the concentration, exposure time, and degree of dissolution of ICG dye during cataract surgery.

  17. Rapid measurement of indocyanine green retention by pulse spectrophotometry: a validation study in 70 patients with Child-Pugh A cirrhosis before hepatectomy for hepatocellular carcinoma.

    Science.gov (United States)

    Cheung, Tan To; Chan, See Ching; Chok, Kenneth S H; Chan, Albert C Y; Yu, Wan Ching; Poon, Ronnie T P; Lo, Chung Mau; Fan, Sheung Tat

    2012-06-01

    The indocyanine green (ICG) retention test is the most popular liver function test for selecting patients for major hepatectomy. Traditionally, it is done using spectrophotometry with serial blood sampling. The newly-developed pulse spectrophotometry is a faster alternative, but its accuracy on Child-Pugh A cirrhotic patients undergoing hepatectomy for hepatocellular carcinoma has not been well documented. This study aimed to assess the accuracy of the LiMON(®), one of the pulse spectrophotometry systems, in measuring preoperative ICG retention in these patients and to devise an easy formula for conversion of the results so that they can be compared with classical literature records where ICG retention was measured by the traditional method. We measured the liver function of 70 Child-Pugh A cirrhotic patients before hepatectomy for hepatocellular carcinoma from September 2008 to January 2009. ICG retention at 15 minutes measured by traditional spectrophotometry (ICGR15) was compared with ICG retention at 15 minutes measured by the LiMON (ICGR15(L)). The median ICGR15 was 14.7% (5.6%-32%) and the median ICGR15(L) was 10.4% (1.2%-28%). The mean difference between them was -4.3606. There was a strong correlation between ICGR15 and ICGR15(L) (correlation coefficient, 0.844; 95% confidence interval, 0.762-0.899). The following formula was devised: ICGR15=1.16XICGR15(L)+2.73. The LiMON provides a fast and repeatable way to measure ICG retention at 15 minutes, but with constant underestimation of the real value. Therefore, when comparing results obtained by traditional spectrophotometry and the LiMON, adjustment of results from the latter is necessary, and this can be done with a simple mathematical calculation using the above formula.

  18. Indocyanine green retention test (ICG-r15) as a noninvasive predictor of portal hypertension in patients with different severity of cirrhosis.

    Science.gov (United States)

    Pind, Marie-Louise L; Bendtsen, Flemming; Kallemose, Thomas; Møller, Søren

    2016-08-01

    Portal hypertension is a severe consequence of chronic liver disease, responsible for the main clinical complications of cirrhosis. Measurement of the hepatic venous pressure gradient (HVPG) provides important clinical information, but the procedure is invasive and demands expert skills of the staff.In the present study, we aimed to investigate the relationship between the constant infusion indocyanine green (ICG) clearance, the calculated ICG retention test after 15 min (ICG-r15), and HVPG in patients with different severity of cirrhosis for validation of ICG-r15 as a noninvasive predictor of portal hypertension. A total of 325 patients were studied. During a hemodynamic investigation, the ICG clearance was determined using the constant infusion technique and ICG-r15 was calculated. Assessment of the diagnostic performance of ICG clearance and ICG-r15 as predictors of HVPG above 10 mmHg was performed by receiver operating characteristic curve analyses.The ICG clearance and ICG-r15 performed well in all three Child classes, with the most significant results among Child class A patients [area under the receiver operating characteristic (AUROC)=0.832] and less significant results in Child class B (AUROC=0.7448) and Child class C patients (AUROC=0.7392). Only six out of 102 patients in Child class C had HVPG of less than 12 mmHg. ICG-r15 can be used as an indirect assessment of significant portal hypertension in compensated cirrhotic patients. ICG-r15 may be suitable as a screening tool for the identification of patients for endoscopy and measurement of HVPG.Further validation of ICG-r15 together with other predictors of portal hypertension and its clinical use is encouraged.

  19. Comparison between the indocyanine green fluorescence and blue dye methods for sentinel lymph node biopsy using novel fluorescence image-guided resection equipment in different types of hospitals.

    Science.gov (United States)

    He, Kunshan; Chi, Chongwei; Kou, Deqiang; Huang, Wenhe; Wu, Jundong; Wang, Yabing; He, Lifang; Ye, Jinzuo; Mao, Yamin; Zhang, Guo-Jun; Wang, Jiandong; Tian, Jie

    2016-12-01

    Sentinel lymph node biopsy (SLNB) has become a standard of care to detect axillary lymph metastasis in early-stage breast cancer patients with clinically negative axillary lymph nodes. Current SLNB detection modalities comprising a blue dye, a radioactive tracer, or a combination of both have advantages as well as disadvantages. Thus, near-infrared fluorescence imaging using indocyanine green (ICG) has recently been regarded as a novel method that has generated interest for SLNB around the world. However, the lack of appropriate fluorescence imaging systems has hindered further research and wide application of this method. Therefore, we developed novel fluorescence image-guided resection equipment (FIRE) to detect sentinel lymph nodes (SLNs). Moreover, to compare the ICG fluorescence imaging method with the blue dye method and to explore the universal feasibility of the former, a different type of hospital study was conducted. Ninety-nine eligible patients participated in the study at 3 different types of hospitals. After subcutaneous ICG allergy testing, all the patients were subcutaneously injected with methylene blue and ICG into the subareolar area. Consequently, 276 SLNs (range 1-7) were identified in 98 subjects (detection rate: 99%) by using the ICG fluorescence imaging method. In contrast, the blue dye method only identified 202 SLNs (range 1-7) in 91 subjects (detection rate: 91.92%). Besides, the results of the fluorescence imaging method were similar in the 3 hospitals. Our findings indicate the universal feasibility of the ICG fluorescence imaging method for SLNB using the fluorescence image-guided resection equipment in early breast cancer detection. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Superselective intra-arterial hepatic injection of indocyanine green (ICG) for fluorescence image-guided segmental positive staining: experimental proof of the concept.

    Science.gov (United States)

    Diana, Michele; Liu, Yu-Yin; Pop, Raoul; Kong, Seong-Ho; Legnèr, Andras; Beaujeux, Remy; Pessaux, Patrick; Soler, Luc; Mutter, Didier; Dallemagne, Bernard; Marescaux, Jacques

    2017-03-01

    Intraoperative liver segmentation can be obtained by means of percutaneous intra-portal injection of a fluorophore and illumination with a near-infrared light source. However, the percutaneous approach is challenging in the minimally invasive setting. We aimed to evaluate the feasibility of fluorescence liver segmentation by superselective intra-hepatic arterial injection of indocyanine green (ICG). Eight pigs (mean weight: 26.01 ± 5.21 kg) were involved. Procedures were performed in a hybrid experimental operative suite equipped with the Artis Zeego ® , multiaxis robotic angiography system. A pneumoperitoneum was established and four laparoscopic ports were introduced. The celiac trunk was catheterized, and a microcatheter was advanced into different segmental hepatic artery branches. A near-infrared laparoscope (D-Light P, Karl Storz) was used to detect the fluorescent signal. To assess the correspondence between arterial-based fluorescence demarcation and liver volume, metallic markers were placed along the fluorescent border, followed by a 3D CT-scanning, after injecting intra-arterial radiological contrast (n = 3). To assess the correspondence between arterial and portal supplies, percutaneous intra-portal angiography and intra-arterial angiography were performed simultaneously (n = 1). Bright fluorescence signal enhancing the demarcation of target segments was obtained from 0.1 mg/mL, in matter of seconds. Correspondence between the volume of hepatic segments and arterial territories was confirmed by CT angiography. Higher background fluorescence noise was found after positive staining by intra-portal ICG injection, due to parenchymal accumulation and porto-systemic shunting. Intra-hepatic arterial ICG injection, rapidly highlights hepatic target segment borders, with a better signal-to-background ratio as compared to portal vein injection, in the experimental setting.

  1. Smart human serum albumin-indocyanine green nanoparticles generated by programmed assembly for dual-modal imaging-guided cancer synergistic phototherapy.

    Science.gov (United States)

    Sheng, Zonghai; Hu, Dehong; Zheng, Mingbin; Zhao, Pengfei; Liu, Huilong; Gao, Duyang; Gong, Ping; Gao, Guanhui; Zhang, Pengfei; Ma, Yifan; Cai, Lintao

    2014-12-23

    Phototherapy, including photodynamic therapy (PDT) and photothermal therapy (PTT), is a light-activated local treatment modality that is under intensive preclinical and clinical investigations for cancer. To enhance the treatment efficiency of phototherapy and reduce the light-associated side effects, it is highly desirable to improve drug accumulation and precision guided phototherapy for efficient conversion of the absorbed light energy to reactive oxygen species (ROS) and local hyperthermia. In the present study, a programmed assembly strategy was developed for the preparation of human serum albumin (HSA)-indocyanine green (ICG) nanoparticles (HSA-ICG NPs) by intermolecular disulfide conjugations. This study indicated that HSA-ICG NPs had a high accumulation with tumor-to-normal tissue ratio of 36.12±5.12 at 24 h and a long-term retention with more than 7 days in 4T1 tumor-bearing mice, where the tumor and its margin, normal tissue were clearly identified via ICG-based in vivo near-infrared (NIR) fluorescence and photoacoustic dual-modal imaging and spectrum-resolved technology. Meanwhile, HSA-ICG NPs efficiently induced ROS and local hyperthermia simultaneously for synergetic PDT/PTT treatments under a single NIR laser irradiation. After an intravenous injection of HSA-ICG NPs followed by imaging-guided precision phototherapy (808 nm, 0.8 W/cm2 for 5 min), the tumor was completely suppressed, no tumor recurrence and treatments-induced toxicity were observed. The results suggest that HSA-ICG NPs generated by programmed assembly as smart theranostic nanoplatforms are highly potential for imaging-guided cancer phototherapy with PDT/PTT synergistic effects.

  2. Near-infrared fluorescence cholangiography with indocyanine green for biliary atresia. Real-time imaging during the Kasai procedure: a pilot study.

    Science.gov (United States)

    Hirayama, Yutaka; Iinuma, Yasushi; Yokoyama, Naoyuki; Otani, Tetsuya; Masui, Daisuke; Komatsuzaki, Naoko; Higashidate, Naruki; Tsuruhisa, Shiori; Iida, Hisataka; Nakaya, Kengo; Naito, Shinichi; Nitta, Koju; Yagi, Minoru

    2015-12-01

    Hepatoportoenterostomy (HPE) with the Kasai procedure is the treatment of choice for biliary atresia (BA) as the initial surgery. However, the appropriate level of dissection level of the fibrous cone (FC) of the porta hepatis (PH) is frequently unclear, and the procedure sometimes results in unsuccessful outcomes. Recently, indocyanine green near-infrared fluorescence imaging (ICG-FCG) has been developed as a form of real-time cholangiography. We applied this technique in five patients with BA to visualize the biliary flow at the PH intraoperatively. ICG was injected intravenously the day before surgery as the liver function test, and the liver was observed with a near-infrared camera system during the operation while the patient's feces was also observed. In all patients, the whole liver fluoresced diffusely with ICG-containing stagnant bile, whereas no extrahepatic structures fluoresced. The findings of the ICG fluorescence pattern of the PH after dissection of the FC were classified into three types: spotty fluorescence, one patient; diffuse weak fluorescence, three patients; and diffuse strong fluorescence, one patient. In all five patients, the feces evacuated after HPE showed distinct fluorescent spots, although that obtained before surgery showed no fluorescence. One patient with diffuse strong fluorescence who did not achieve JF underwent living related liver transplantation six months after the initial HPE procedure. Four patients, including three cases involving diffuse weak fluorescence and one case involving spotty fluorescence showed weak fluorescence compared to that of the surrounding liver surface. We were able to detect the presence of bile excretion at the time of HPE intraoperatively and successfully evaluated the extent of bile excretion using this new technique. Furthermore, the ICG-FCG findings may provide information leading to a new classification and potentially function as an indicator predicting the clinical outcomes after HPE.

  3. Tailoring through Technology: A Retrospective Review of a Single Surgeon's Experience with Implant-Based Breast Reconstruction before and after Implementation of Laser-Assisted Indocyanine Green Angiography.

    Science.gov (United States)

    Harless, Christin A; Jacobson, Steven R

    2016-05-01

    Reported complication rates of implant-based breast reconstruction in the literature exceed 50%, with mastectomy skin flap necrosis reported to occur in up to 25% of cases. Laser-assisted indocyanine green angiography (LA-ICGA) technology allows the surgeon to optimize preservation of the mastectomy skin flap while avoiding skin necrosis. The purpose of this study was to determine if outcomes of breast reconstruction are beneficially affected by using LA-ICGA. A total 269 consecutive women (467 breast reconstructions) undergoing implant-based breast reconstruction from 2008 to 2013 were examined. The complication rates of those who underwent reconstruction prior to the implementation of LA-ICGA were compared with those who were reconstructed after implementation of LA-ICGA. A total of 254 consecutive breast reconstructions were performed prior to implementation of LA-ICGA, and 213 breasts were reconstructed with the use of LA-ICGA. After implementation of LA-ICGA System, the rate of mastectomy skin flap necrosis decreased by 86% (6.7% versus 0.9%, p = 0.02). The overall complication rate prior to LA-ICGA was 13.8% compared with 6.6% with the use of LA-ICGA (p = 0.01). After LA-ICGA was incorporated, the percentage of patients undergoing single-stage reconstruction increased from 12% to 32% (p = <0.001). Implementation of LA-ICGA provides the surgeon with an objective assessment of mastectomy flap perfusion resulting in a trend toward overall reduction in complications as well as an 86% decrease in the rate of subsequent skin necrosis. The objective assessment of mastectomy flap perfusion allows the surgeon to tailor breast reconstruction intraoperatively, in real-time, adjusting for the individual patient's mastectomy flap perfusion. © 2016 Wiley Periodicals, Inc.

  4. Sentinel Node Mapping Using Indocyanine Green and Near-infrared Fluorescence Imaging Technology for Uterine Malignancies: Preliminary Experience With the Da Vinci Xi System.

    Science.gov (United States)

    Siesto, Gabriele; Romano, Fabrizio; Fiamengo, Barbara; Vitobello, Domenico

    2016-01-01

    Sentinel lymph node (SLN) mapping has emerged as the new frontier for the surgical staging of apparently early-stage cervical and endometrial cancer. Different colorimetric and radioactive tracers, alone and in combination, have been proposed with encouraging results. Fluorometric mapping using indocyanine green (ICG) appears to be a suitable and attractive alternative to provide reliable staging [1-4]. In this video, we present the technique of SLN mapping in 2 cases (1 endometrial and 1 cervical cancer, respectively) using ICG and the near-infrared technology provided by the newest Da Vinci Xi robotic system (Intuitive Surgical Inc., Sunnyvale, CA). Together we report the results of our preliminary experience on the first 20 cases performed. The new robotic Da Vinci Xi system was available at our institution since May 2015. Upon institutional review board/ethical committee approval, all consecutive patients with early-stage endometrial and cervical cancer who were judged suitable for robotic surgery have been enrolled for SLN mapping with ICG. We adopted the Memorial Sloan Kettering Cancer Center SLN algorithm; the tracer was delivered into the cervix in all cases. Four milliliters (1.25 mg/mL) of ICG was injected divided into the 3- and 9-o'clock positions of the cervix alone, with 1 mL deep into the stroma and 1 mL submucosally at the skin incision. Sentinel lymph nodes were examined with a protocol including both ultrastaging with immunohistochemistry [3] and 1-step nucleic acid amplification assay [5,6] under a parallel protocol of study. During the study period, 20 cases were managed; 14 and 6 patients had endometrial and cervical cancer, respectively. SLN was detected in all cases (20/20, 100%). Bilateral SLNs were detected in 17 of 20 (85.0%) cases. Based on preoperative and intraoperative findings, 13 (65.0%) patients received systematic pelvic lymphadenectomy after SLN mapping. Three (15.0%) patients had microscopic nodal metastases on SLN. No

  5. Complex microcirculation patterns detected by confocal indocyanine green angiography predict time to growth of small choroidal melanocytic tumors: MuSIC Report II.

    Science.gov (United States)

    Mueller, Arthur J; Freeman, William R; Schaller, Ulrich C; Kampik, Anselm; Folberg, Robert

    2002-12-01

    Multiple independent laboratories have confirmed the histologic observation that some tumor microcirculation patterns (MCPs) in uveal melanomas are associated strongly with death resulting from metastatic disease. Because these patterns are imageable with confocal indocyanine green angiography (ICG), we designed a prospective study to evaluate whether these angiographically detectable MCPs predict time to tumor growth. Observational case series, prospective, non-randomized. Ninety-eight patients with unilateral, small, choroidal melanocytic tumors. The following information and tumor characteristics were recorded for each patient: demographic parameters, best-corrected visual acuity, intraocular pressure, related visual symptoms, location and dimension of tumor, pigmentation, orange pigment, drusen, tumor-associated hemorrhage, subretinal fluid, and confocal ICG angiographically determined microcirculation patterns-silent (avascularity), normal (preexisting normal choroidal vessels within the tumor), straight vessels, parallel without and with cross-linking, arcs without and with branching, loops, and networks. Time to growth of the tumor, with growth defined as an increase in the maximal apical tumor height of 0.5 mm measured by standardized A-scan ultrasonography, photographic documentation of an increase of the largest basal diameter of at least 1.5 mm, advancement of one tumor border of at least 0.75 mm, or a combination thereof. Twenty-eight of the 98 tumors in this study (29%) met the predetermined criteria for tumor growth. The median time to growth was 127 days (range, 51-625 days). The following tumor characteristics were significantly associated with time to tumor growth: flashes (P = 0.0224), orange pigment (P = 0.012), subretinal fluid (P < 0.001), maximum basal tumor diameter at initial examination (P = 0.015), maximum apical tumor height (P < 0.001), parallel with cross-linking MCP (P < 0.001), arcs with branching MCP (P = 0.006), loops (P < 0

  6. Association between pretreatment retention rate of indocyanine green 15 min after administration and life prognosis in patients with HCC treated by proton beam therapy

    International Nuclear Information System (INIS)

    Mizumoto, Masashi; Oshiro, Yoshiko; Okumura, Toshiyuki; Fukuda, Kuniaki; Fukumitsu, Nobuyoshi; Abei, Masato; Ishikawa, Hitoshi; Ohnishi, Kayoko; Numajiri, Haruko; Tsuboi, Koji; Sakurai, Hideyuki

    2014-01-01

    Purpose: The Child-Pugh score is often used to judge the outcome of radiotherapy for hepatocellular carcinoma (HCC). The retention rate of indocyanine green 15 min after administration (ICG R15) can also be used to predict prognosis after liver resection. We evaluated the utility of ICG R15 for prediction of outcomes after proton beam therapy (PBT) for HCC. Methods and materials: A retrospective evaluation was performed in 250 patients who received PBT between 2002 and 2007. The patients (178 males and 72 females) had a median age of 71 years (range: 43–88). Child-Pugh categories were A (score 5–6), B (7–9), and C (10–15) in 197, 51, and 2 patients, respectively. ICG scores were 0–<10, 10–<20, 20–<30, 30–<40 and ⩾40 in 27, 99, 59, 28 and 37 patients, respectively; including 26, 92, 45, 16 and 18 Child-Pugh A patients and 1, 8, 14, 11, and 17 Child-Pugh B patients, respectively. Survival times from the start of PBT were compared between Child-Pugh A and B patients, and among each ICG group. Results: The median survival times were 61 months (95% CI: 50–72 months) in all patients, and 64 and 20 months in Child-Pugh A and B patients, respectively (p = 0.001), The 3-year survival rates were 72%, 72%, 75%, 63%, and 26% in patients with ICG scores of 0–<10, 10–<20, 20–<30, 30–<40, and ⩾40 (p = 0.001); 70%, 75%, 77%, 65%, and 38% in these respective groups in Child-Pugh A patients (p = 0.02); and 100%, 57%, 67%, 36%, and 14% in Child-Pugh B patients (p = 0.173, not significant). Multivariate analysis showed that low ICG R15 and the absence of portal vein tumor thrombus were associated with good survival. Conclusions: Pretreatment ICG R15 is a useful prognostic factor for prediction of outcome of PBT in HCC patients, especially in those with Child-Pugh A liver function

  7. Correlation between HBsAg, prothrombin time activity, and indocyanine green retention rate at 15 minutes in patients with HBeAg-positive chronic HBV infection

    Directory of Open Access Journals (Sweden)

    FAN Wenhai

    2016-11-01

    Full Text Available ObjectiveTo investigate the correlation between HBsAg, prothrombin time activity (PTA, and indocyanine green retention rate at 15 minutes (ICG R15 in patients with HBeAg-positive chronic HBV infection. MethodsA total of 92 patients with HBeAg-positive chronic HBV infection who were admitted to The First Hospital of Lanzhou University from December 2015 to April 2016 were enrolled and divided into chronic hepatitis B (CHB group (24 patients, compensated liver cirrhosis group (38 patients, and decompensated liver cirrhosis group (30 patients. Serum HBsAg quantitation, PTA test, and liver reserve function test (ICG R15 were performed for all patients. The chi-square test was used for comparison of categorical data between groups, an analysis of variance was used for comparison of continuous data between multiple groups, and a Pearson correlation analysis was also performed. ResultsThere were significant differences between the three groups in serum HBsAg quantitation (3.82±0.43 log10IU/ml vs 2.88±0.36 log10IU/ml vs 2.60±0.27 log10IU/ml, F=25.19, P<0.001, ICG R15 (7.51%±3.10% vs 9.57%±8.18% vs 24.13%±14.28%, F=24.00, P=0.001, and PTA (8100%±1762% vs 83.08%±9.64% vs 62.32%±16.90%, F=13.42, P=0.009. The correlation analysis showed that PTA was negatively correlated with ICG R15 in all three groups (r=-0.948, -0.602, and -0.735, all P<0.01. In the compensated liver cirrhosis group and decompensated liver cirrhosis group, HBsAg was positively correlated with PTA (r=0.410 and 0.473, both P<0.05 and negatively correlated with ICG R15 (r=-0.427 and -0.768, P<0.01. ConclusionIn HBeAg positive patients, there are certain correlations between HBsAg, PTA, and ICG R15, which, to a certain degree, reflects the liver reserve function in patients with chronic HBV infection.

  8. Rose Bengal Photothrombosis by Confocal Optical Imaging In Vivo: A Model of Single Vessel Stroke.

    Science.gov (United States)

    Talley Watts, Lora; Zheng, Wei; Garling, R Justin; Frohlich, Victoria C; Lechleiter, James Donald

    2015-06-23

    In vivo imaging techniques have increased in utilization due to recent advances in imaging dyes and optical technologies, allowing for the ability to image cellular events in an intact animal. Additionally, the ability to induce physiological disease states such as stroke in vivo increases its utility. The technique described herein allows for physiological assessment of cellular responses within the CNS following a stroke and can be adapted for other pathological conditions being studied. The technique presented uses laser excitation of the photosensitive dye Rose Bengal in vivo to induce a focal ischemic event in a single blood vessel. The video protocol demonstrates the preparation of a thin-skulled cranial window over the somatosensory cortex in a mouse for the induction of a Rose Bengal photothrombotic event keeping injury to the underlying dura matter and brain at a minimum. Surgical preparation is initially performed under a dissecting microscope with a custom-made surgical/imaging platform, which is then transferred to a confocal microscope equipped with an inverted objective adaptor. Representative images acquired utilizing this protocol are presented as well as time-lapse sequences of stroke induction. This technique is powerful in that the same area can be imaged repeatedly on subsequent days facilitating longitudinal in vivo studies of pathological processes following stroke.

  9. 20 g PPV with indocyanine green-assisted ILM peeling versus 23 g PPV with brilliant blue G-assisted ILM peeling for epiretinal membrane.

    Science.gov (United States)

    Manousaridis, Kleanthis; Peter, Silvia; Mennel, Stefan

    2016-06-01

    To compare the anatomical and visual outcomes of 20 gauge (g) pars plana vitrectomy (PPV) with indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling and 23 g PPV with brilliant blue G (BBG)-assisted ILM peeling for idiopathic epiretinal membrane (ERM). 38 eyes of 38 patients with idiopathic ERM were included. They were divided in two groups: group 1 (18 eyes) underwent 20 g PPV with ICG-assisted ILM peeling and group 2 (20 eyes) 23 g PPV with BBG-assisted ILM peeling. Postoperative best-corrected visual acuity (BCVA) and central macular thickness (CMT) were compared. Average BCVA in group 1 improved significantly from 0.60 logarithm of the minimal angle of resolution (log MAR) at baseline to 0.3 log MAR postoperatively. Average BCVA in group 2 improved significantly from 0.60 log MAR at baseline to 0.3 log MAR postoperatively. Mean CMT reduced significantly from 473 to 375 μm in group 1 and from 486 to 396 μm in group 2. There were no significant differences in the BCVA and CMT between the groups. Both surgical methods appeared to be safe and provided similar anatomical and visual outcomes.

  10. Blocking of platelets or intrinsic coagulation pathway-driven thrombosis does not prevent cerebral infarctions induced by photothrombosis.

    Science.gov (United States)

    Kleinschnitz, Christoph; Braeuninger, Stefan; Pham, Mirko; Austinat, Madeleine; Nölte, Ingo; Renné, Thomas; Nieswandt, Bernhard; Bendszus, Martin; Stoll, Guido

    2008-04-01

    Models of photochemically-induced thrombosis are widely used in cerebrovascular research. Photothrombotic brain infarctions can be induced by systemic application of photosensitizing dyes followed by focal illumination of the cerebral cortex. Although the ensuing activation of platelets is well established, their contribution for thrombosis and tissue damage has not formally been proved. Infarction to the cerebral cortex was induced in mice by Rose Bengal and a cold light source. To assess the functional role of platelets, animals were platelet-depleted by anti-GPIbalpha antibodies or treated with GPIIb/IIIa-blocking F(ab)(2) fragments. The significance of the plasmatic coagulation cascade was determined by using blood coagulation factor XII (FXII)-deficient mice or heparin. Infarct development and infarct volumes were determined by serial MRI and conventional and electron microscopy. There was no difference in development and final size of photothrombotic infarctions in mice with impaired platelet function. Moreover, deficiency of FXII, which initiates the intrinsic pathway of coagulation and is essential for thrombus formation, or blockade of FXa, the key protease during the waterfall cascade of plasmatic coagulation, by heparin likewise did not affect lesion development. Our data demonstrate that platelet activation, factor XII-driven thrombus formation, and plasmatic coagulation pathways downstream of FX are not a prerequisite for ensuing tissue damage in models of photothrombotic vessel injury indicating that other pathomechanisms are involved. We suggest that this widely used model does not depend on platelet- or plasmatic coagulation-derived thrombosis.

  11. Photothrombosis-Induced Infarction of the Mouse Cerebral Cortex Is Not Affected by the Nrf2-Activator Sulforaphane

    OpenAIRE

    Porritt, Michelle J.; Andersson, Helene C.; Hou, Linda; Nilsson, Åsa; Pekna, Marcela; Pekny, Milos; Nilsson, Michael

    2012-01-01

    Sulforaphane-induced activation of the transcription factor NF-E2 related factor 2 (Nrf2 or the gene Nfe2l2) and subsequent induction of the phase II antioxidant system has previously been shown to exert neuroprotective action in a transient model of focal cerebral ischemia. However, its ability to attenuate functional and cellular deficits after permanent focal cerebral ischemia is not clear. We assessed the neuroprotective effects of sulforaphane in the photothrombotic model of permanent fo...

  12. Sympathetic ophthalmia - histopathological correlation with fluorescein and indocyanine green angiography: case report Oftalmia simpática - correlação da histopatologia com a angiografia por fluoresceína e indocianina verde: relato de caso

    Directory of Open Access Journals (Sweden)

    Antônio Marcelo Barbante Casella

    2008-12-01

    Full Text Available This study correlates fluorescein angiography (FA and indocyanine green angiography (ICGA to histopathologic findings in a patient with sympathetic ophtalmia. A male with a perforated trauma in right eye presented after two months a decrease in visual acuity of the left eye. FA and ICGA were performed and the images were correlated with the histopathologic findings of the enucleated eye; FA showed background areas of homogeneous hypofluorescence in the arterial and venous phases, as well as areas of granular progressive hyperfluorescence and leakage from the optic disc. ICGA showed areas of hypofluorescence in the early and intermediate phases of the examination, which persisted until the late phase. During the early phase, there was also diffuse hypofluorescence caused by blockage that allowed observation of areas of partial choroidal circulation. The histopathology of the enucleated right eye showed diffuse choriocapillaris edema and inflammation of the choroids, focal areas of hyperplasia of the retinal pigment epithelium (RPE as well as foci of epithelioid cells located between the choroid and the RPE. Furthermore, lymphocytic infiltration of the episcleral veins and retinal detachment were present. The hyperfluorescence observed on FA was correlated to retinal detachment and optic nerve inflammation. The hypofluorescence noted on FA and ICGA corresponded to the presence of blocking inflammatory cells (Dalen-Fuchs-like nodules and to diffuse choriocapillaris edema.O objetivo deste relato de caso foi correlacionar achados da histopatologia com a angiografia por fluoresceína (AF e por indocianina verde (AIV em um paciente com oftalmia simpática. Após dois meses de trauma perfurante no olho direito, o paciente apresentou baixa acuidade visual no olho esquerdo (OE. A AF do OE mostrou áreas de hipofluorescência homogênea na fase arterial e venosa, áreas de progressiva hiperfluorescência granular e vazamento do disco. A AIV mostrou

  13. Recirculatory modeling in man using Indocyanine green

    NARCIS (Netherlands)

    Reekers, Marije

    2012-01-01

    Titration to effect is the most important action anesthesiologists use to assure adequacy of anesthesia and safeguard their patients from serious side effects. For a proper titration to effect the anesthesiologist takes into consideration the historical response to a given dose to estimate the

  14. Fully integrated high-speed intravascular optical coherence tomography/near-infrared fluorescence structural/molecular imaging in vivo using a clinically available near-infrared fluorescence-emitting indocyanine green to detect inflamed lipid-rich atheromata in coronary-sized vessels.

    Science.gov (United States)

    Lee, Sunki; Lee, Min Woo; Cho, Han Saem; Song, Joon Woo; Nam, Hyeong Soo; Oh, Dong Joo; Park, Kyeongsoon; Oh, Wang-Yuhl; Yoo, Hongki; Kim, Jin Won

    2014-08-01

    Lipid-rich inflamed coronary plaques are prone to rupture. The purpose of this study was to assess lipid-rich inflamed plaques in vivo using fully integrated high-speed optical coherence tomography (OCT)/near-infrared fluorescence (NIRF) molecular imaging with a Food and Drug Administration-approved indocyanine green (ICG). An integrated high-speed intravascular OCT/NIRF imaging catheter and a dual-modal OCT/NIRF system were constructed based on a clinical OCT platform. For imaging lipid-rich inflamed plaques, the Food and Drug Administration-approved NIRF-emitting ICG (2.25 mg/kg) or saline was injected intravenously into rabbit models with experimental atheromata induced by balloon injury and 12- to 14-week high-cholesterol diets. Twenty minutes after injection, in vivo OCT/NIRF imaging of the infrarenal aorta and iliac arteries was acquired only under contrast flushing through catheter (pullback speed up to ≤20 mm/s). NIRF signals were strongly detected in the OCT-visualized atheromata of the ICG-injected rabbits. The in vivo NIRF target-to-background ratio was significantly larger in the ICG-injected rabbits than in the saline-injected controls (Pfluorescence reflectance imaging, which correlated well with the in vivo target-to-background ratios (Pfluorescence microscopy, and histopathology also corroborated the in vivo imaging findings. Integrated OCT/NIRF structural/molecular imaging with a Food and Drug Administration -approved ICG accurately identified lipid-rich inflamed atheromata in coronary-sized vessels. This highly translatable dual-modal imaging approach could enhance our capabilities to detect high-risk coronary plaques. © 2014 American Heart Association, Inc.

  15. Malachite green mediates homodimerization of antibody VL domains to form a fluorescent ternary complex with singular symmetric interfaces

    Science.gov (United States)

    Szent-Gyorgyi, Chris; Stanfield, Robyn L.; Andreko, Susan; Dempsey, Alison; Ahmed, Mushtaq; Capek, Sara; Waggoner, Alan; Wilson, Ian A.; Bruchez, Marcel P.

    2013-01-01

    We report that a symmetric small molecule ligand mediates the assembly of antibody light chain variable domains (VLs) into a correspondent symmetric ternary complex with novel interfaces. The L5* Fluorogen Activating Protein (FAP) is a VL domain that binds malachite green dye (MG) to activate intense fluorescence. Crystallography of liganded L5* reveals a 2:1 protein:ligand complex with inclusive C2 symmetry, where MG is almost entirely encapsulated between an antiparallel arrangement of the two VL domains. Unliganded L5* VL domains crystallize as a similar antiparallel VL/VL homodimer. The complementarity determining regions (CDRs) are spatially oriented to form novel VL/VL and VL/ligand interfaces that tightly constrain a propeller conformer of MG. Binding equilibrium analysis suggests highly cooperative assembly to form a very stable VL/MG/VL complex, such that MG behaves as a strong chemical inducer of dimerization. Fusion of two VL domains into a single protein tightens MG binding over 1,000-fold to low picomolar affinity without altering the large binding enthalpy, suggesting that bonding interactions with ligand and restriction of domain movements make independent contributions to binding. Fluorescence activation of a symmetrical fluorogen provides a selection mechanism for the isolation and directed evolution of ternary complexes where unnatural symmetric binding interfaces are favored over canonical antibody interfaces. As exemplified by L5*, these self-reporting complexes may be useful as modulators of protein association or as high affinity protein tags and capture reagents. PMID:23978698

  16. Green mediated synthesis and characterization of ZnO nanoparticles using Euphorbia Jatropa latex as reducing agent

    Directory of Open Access Journals (Sweden)

    M.S. Geetha

    2016-09-01

    Full Text Available Presently the progress of green chemistry in the synthesis of nanoparticles with the use of plants has engrossed a great attention. This study reports the synthesis of ZnO using latex of Euphorbia Jatropa as reducing agent. As prepared product was characterized by powder X-ray diffractometer (PXRD, Fourier transform infra-red spectroscopy (FTIR, scanning electron microscopy–energy dispersive spectroscopy (SEM–EDS, transmission electron microscopy (TEM, X-ray photo electron spectroscopy (XPS, Rietveld refinement, UV–Visible spectroscopy and photoluminescence (PL. The concentration of plant latex plays an important role in controlling the size of the particle and its morphology. PXRD graphs showed the well crystallisation of the particles. The average particle size was calculated using Scherrer equation and advanced Williamson Hall (WH plots. The average particle size was around 15 nm. This result was also supported by SEM and TEM analyses. FTIR shows the characteristic peak of ZnO at 435 cm−1. SEM and TEM micrographs show that the particles were almost hexagonal in nature. EDS of SEM analysis confirmed that the elements are only Zn and O. EDS confirmed purity of ZnO. Atomic states were confirmed by XPS results. Crystal parameters were determined using Rietveld refinement. From UV–Visible spectra average energy gap was calculated which is ∼3.63 eV. PL studies showed UV emission peak at 392 nm and broad band visible emission centred in the range 500–600 nm. The Commission International de I'Eclairage and colour correlated temperature coordinates were estimated for ZnO prepared using 2 ml, 4 ml and 6 ml Jatropa latex. The results indicate that the phosphor may be suitable for white light emitting diode (WLED. The study fruitfully reveals simple, fast, economical and eco friendly method of synthesis of multifunctional ZnO nanoparticles (Nps.

  17. Monomer adsorption of indocyanine green to gold nanoparticles

    NARCIS (Netherlands)

    Guerrini, Luca; Hartsuiker, Liesbeth; Manohar, Srirang; Otto, Cornelis

    2011-01-01

    NIR-dye encoded gold nanoparticles (GNP) are rapidly emerging as contrast agents in many bio-imaging/sensing applications. The coding process is usually carried out without control or a clear understanding of the metal–liquid interface properties which, in contrast, are critical in determining the

  18. Indocyanine green fluorescence angiography during laparoscopic low anterior resection: results of a case-matched study.

    Science.gov (United States)

    Boni, Luigi; Fingerhut, Abe; Marzorati, Alessandro; Rausei, Stefano; Dionigi, Gianlorenzo; Cassinotti, Elisa

    2017-04-01

    Colorectal anastomoses after anterior resection for cancer carry a high risk of leakage. Different factors might influence the correct healing of anastomosis, but adequate perfusion of the bowel is highlighted as one of the most important elements. Fluorescence angiography (FA) is a new technique that allows the surgeon to perform real-time intraoperative angiography to evaluate the perfusion of the anastomosis and hence, potentially, reduce leak rate. The aim of this study was to evaluate the impact of FA of the bowel on postoperative complications and anastomotic leakage after laparoscopic anterior resection with total mesorectal excision (TME). FA was performed in all patients undergoing laparoscopic anterior resection with TME for cancer followed by colorectal or coloanal anastomosis. Results were compared to a historical controls group of 38 patients previously operated by the same surgeon for the same indication but without the use of FA. From October 2014 to November 2015, 42 patients underwent laparoscopic anterior resection with TME and FA of the bowel. The surgeon subjectively decided to change the planned anastomotic level of the descending colon due to hypoperfused distal segment in two out of 42 patients in the FA group (4.7 %). Anastomotic leakage, confirmed by postoperative CT scan and water-soluble contrast enema, was found in two cases of a historical controls group and none in the FA group. No adverse events (side effects or allergic reaction) related to FA were recorded. All the other postoperative complications were comparable between the two groups. In our experience, ICG FA was safe and effective in low rectal cancer resection, possibly leading to a reduction in the anastomotic leakage rate after TME.

  19. Intra-Operative Indocyanine Green-Videoangiography (ICG-VA) in ...

    African Journals Online (AJOL)

    Methods: Fifteen consecutive patients with anterior circulation aneurysms who underwent craniotomy and clipping of the aneurysms were included in this study. Intraoperative ICG-VA was performed in all cases after exposure of the aneurysm and the branches in the vicinity of the aneurysm or the parent vessel before ...

  20. Spectral triangulation molecular contrast optical coherence tomography with indocyanine green as the contrast agent

    OpenAIRE

    Yang, Changhuei; McGuckin, Laura E. L.; Simon, John D.; Choma, Michael A.; Applegate, Brian E.; Izatt, Joseph A.

    2004-01-01

    We report a new molecular contrast optical coherence tomography (MCOCT) implementation that profiles the contrast agent distribution in a sample by measuring the agent's spectral differential absorption. The method, spectra triangulation MCOCT, can effectively suppress contributions from spectrally dependent scatterings from the sample without a priori knowledge of the scattering properties. We demonstrate molecular imaging with this new MCOCT modality by mapping the distribution of indocyani...

  1. Enhanced visualization of the bile duct via parallel white light and indocyanine green fluorescence laparoscopic imaging

    Science.gov (United States)

    Demos, Stavros G.; Urayama, Shiro

    2014-03-01

    Despite best efforts, bile duct injury during laparoscopic cholecystectomy is a major potential complication. Precise detection method of extrahepatic bile duct during laparoscopic procedures would minimize the risk of injury. Towards this goal, we have developed a compact imaging instrumentation designed to enable simultaneous acquisition of conventional white color and NIR fluorescence endoscopic/laparoscopic imaging using ICG as contrast agent. The capabilities of this system, which offers optimized sensitivity and functionality, are demonstrated for the detection of the bile duct in an animal model. This design could also provide a low-cost real-time surgical navigation capability to enhance the efficacy of a variety of other image-guided minimally invasive procedures.

  2. Fluorescent Imaging With Indocyanine Green During Laparoscopic Cholecystectomy in Patients at Increased Risk of Bile Duct Injury

    NARCIS (Netherlands)

    Ankersmit, M.; Dam, D.A. van; Rijswijk, A.S. van; Tuynman, J.B.; Meijerink, W.J.H.J.

    2017-01-01

    BACKGROUND: Although rare, injury to the common bile duct (CBD) during laparoscopic cholecystectomy (LC) can be reduced by better intraoperative visualization of the cystic duct (CD) and CBD. The aim of this study was to establish the efficacy of early visualization of the CD and the added value of

  3. Indocyanine green retention test (ICG-r15) as a noninvasive predictor of portal hypertension in patients with different severity of cirrhosis

    DEFF Research Database (Denmark)

    Pind, Marie-Louise Lindberg; Bendtsen, Flemming; Kallemose, Thomas

    2016-01-01

    BACKGROUND AND AIMS: Portal hypertension is a severe consequence of chronic liver disease, responsible for the main clinical complications of cirrhosis. Measurement of the hepatic venous pressure gradient (HVPG) provides important clinical information, but the procedure is invasive and demands...... as a noninvasive predictor of portal hypertension. METHODS: A total of 325 patients were studied. During a hemodynamic investigation, the ICG clearance was determined using the constant infusion technique and ICG-r15 was calculated. RESULTS: Assessment of the diagnostic performance of ICG clearance and ICG-r15...... significant results in Child class B (AUROC=0.7448) and Child class C patients (AUROC=0.7392). Only six out of 102 patients in Child class C had HVPG of less than 12 mmHg. CONCLUSION: ICG-r15 can be used as an indirect assessment of significant portal hypertension in compensated cirrhotic patients. ICG-r15...

  4. Dabrafenib, an inhibitor of RIP3 kinase-dependent necroptosis, reduces ischemic brain injury

    Directory of Open Access Journals (Sweden)

    Shelly A Cruz

    2018-01-01

    Full Text Available Ischemic brain injury triggers neuronal cell death by apoptosis via caspase activation and by necroptosis through activation of the receptor-interacting protein kinases (RIPK associated with the tumor necrosis factor-alpha (TNF-α/death receptor. Recent evidence shows RIPK inhibitors are neuroprotective and alleviate ischemic brain injury in a number of animal models, however, most have not yet undergone clinical trials and safety in humans remains in question. Dabrafenib, originally identified as a B-raf inhibitor that is currently used to treat melanoma, was later revealed to be a potent RIPK3 inhibitor at micromolar concentrations. Here, we investigated whether Dabrafenib would show a similar neuroprotective effect in mice subjected to ischemic brain injury by photothrombosis. Dabrafenib administered intraperitoneally at 10 mg/kg one hour after photothrombosis-induced focal ischemic injury significantly reduced infarct lesion size in C57BL6 mice the following day, accompanied by a markedly attenuated upregulation of TNF-α. However, subsequent lower doses (5 mg/kg/day failed to sustain this neuroprotective effect after 4 days. Dabrafenib blocked lipopolysaccharides-induced activation of TNF-α in bone marrow-derived macrophages, suggesting that Dabrafenib may attenuate TNF-α-induced necroptotic pathway after ischemic brain injury. Since Dabrafenib is already in clinical use for the treatment of melanoma, it might be repurposed for stroke therapy.

  5. Krypton laser-induced photothrombotic distal middle cerebral artery occlusion without craniectomy in mice.

    Science.gov (United States)

    Sugimori, Hiroshi; Yao, Hiroshi; Ooboshi, Hiroaki; Ibayashi, Setsuro; Iida, Mitsuo

    2004-08-01

    Recent advances in genetical engineering of the mouse have highlighted the importance of reproducible and less invasive models of cerebral ischemia in mice. In this paper, we developed minimally invasive and reproducible model of distal middle cerebral artery (MCA) occlusion in mice using krypton (Kr) laser-induced photothrombosis. C57BL/6 or BALB mice (n=8 each) were anesthetized with halothane. The skin was cut, the temporal muscle was retracted, and the right distal MCA was observed through the skull. A Kr laser beam of wavelength 568 nm was focused onto the MCA over the intact skull. Upon laser irradiation, intravenous administration of a rose bengal solution was begun. After 4 min of irradiation, the laser beam was refocused on the MCA just proximal to the first spot, and another 4-min irradiation was performed. Then, the right common carotid artery (CCA) was ligated. Three days later, the brain was removed, and infarct volume was determined. Infarction confined almost solely to the cortical area was produced in each mouse. Mean infarct volume in C57BL/6 mice was 25.2+/-13.7 mm3. The BALB mice group showed significantly larger and more reproducible infarction (44.1+/-5.2 mm3; the coefficient of variation was 12%) than did C57BL/6 mice (P<0.005). Our photothrombosis model of stroke in mice can be performed without craniectomy, and its reproducibility is satisfactory when using BALB mice.

  6. Near-Infrared Fluorescence Laparoscopy of the Cystic Duct and Artery in Pigs : Performance of a Preclinical Dye

    NARCIS (Netherlands)

    Schols, Rutger M.; Lodewick, Toine M.; Bouvy, Nicole D.; van Dam, Dieuwertje A.; Meijerink, Wilhelmus J. H. J.; van Dam, Gooitzen M.; Dejong, Cornelis H. C.; Stassen, Laurents P. S.

    2014-01-01

    Background: Near-infrared fluorescence laparoscopy after intravenous indocyanine green (ICG) administration has been proposed as a promising surgical imaging technique for real-time visualization of the extrahepatic bile ducts and arteries in clinical laparoscopic cholecystectomies. However,

  7. Stimulation of the sphenopalatine ganglion induces reperfusion and blood-brain barrier protection in the photothrombotic stroke model.

    Directory of Open Access Journals (Sweden)

    Haviv Levi

    Full Text Available The treatment of stroke remains a challenge. Animal studies showing that electrical stimulation of the sphenopalatine ganglion (SPG exerts beneficial effects in the treatment of stroke have led to the initiation of clinical studies. However, the detailed effects of SPG stimulation on the injured brain are not known.The effect of acute SPG stimulation was studied by direct vascular imaging, fluorescent angiography and laser Doppler flowmetry in the sensory motor cortex of the anaesthetized rat. Focal cerebral ischemia was induced by the rose bengal (RB photothrombosis method. In chronic experiments, SPG stimulation, starting 15 min or 24 h after photothrombosis, was given for 3 h per day on four consecutive days. Structural damage was assessed using histological and immunohistochemical methods. Cortical functions were assessed by quantitative analysis of epidural electro-corticographic (ECoG activity continuously recorded in behaving animals.Stimulation induced intensity- and duration-dependent vasodilation and increased cerebral blood flow in both healthy and photothrombotic brains. In SPG-stimulated rats both blood brain-barrier (BBB opening, pathological brain activity and lesion volume were attenuated compared to untreated stroke animals, with no apparent difference in the glial response surrounding the necrotic lesion.SPG-stimulation in rats induces vasodilation of cortical arterioles, partial reperfusion of the ischemic lesion, and normalization of brain functions with reduced BBB dysfunction and stroke volume. These findings support the potential therapeutic effect of SPG stimulation in focal cerebral ischemia even when applied 24 h after stroke onset and thus may extend the therapeutic window of currently administered stroke medications.

  8. TfR Binding Peptide Screened by Phage Display Technology ...

    African Journals Online (AJOL)

    Purpose: To screen an hTfR affinity peptide and investigate its activity in vitro. Methods: hTfR ... Keywords: Peptide, hTfR, Transferrin receptor, Phage display technology, Enhanced green ..... mediated uptake of peptides that bind the human.

  9. Host-guest chemistry of dendrimer-drug complexes: 7. Formation of stable inclusions between acetylated dendrimers and drugs bearing multiple charges.

    Science.gov (United States)

    Fang, Min; Zhang, Jiahai; Wu, Qinglin; Xu, Tongwen; Cheng, Yiyun

    2012-03-15

    Drug molecules bearing multiple charges usually form precipitates with cationic dendrimers, which presents a challenge during the preparation of dendrimer inclusions for these drugs. In the present study, fully acetylated polyamidoamine (PAMAM) dendrimers were proposed as stable vehicles for drug molecules bearing two negative charges such as Congo red and indocyanine green. NMR techniques including (1)H NMR and (1)H-(1)H NOESY were used to characterize the host-guest chemistry of acetylated dendrimer and these guest molecules. The cationic PAMAM dendrimer was found to form a precipitate with Congo red and indocyanine green, but the acetylated one avoided the formation of cross-linking structures in aqueous solutions. NOESY studies revealed the encapsulation of Congo red and indocyanine green within the interior cavities of PAMAM dendrimers at mild acidic conditions and acetylated dendrimers show much stronger ability to encapsulate the guest molecules than cationic ones. Also, UV-vis-NIR studies suggest that acetylated dendrimers significantly improve the photostability of indocyanine green and prevent the formation of indocyanine green J-aggregates in aqueous solutions. The present study provides a new insight into dendrimer-based host-guest systems, especially for those guest molecules bearing multiple charges. © 2012 American Chemical Society

  10. Constant infusion transpulmonary thermodilution for the assessment of cardiac output in exercising humans

    DEFF Research Database (Denmark)

    Calbet, J A L; Mortensen, Stefan; Munch, G D W

    2016-01-01

    To determine the accuracy and precision of constant infusion transpulmonary thermodilution cardiac output (CITT-Q) assessment during exercise in humans, using indocyanine green (ICG) dilution and bolus transpulmonary thermodilution (BTD) as reference methods, cardiac output (Q) was determined......: 6.1-11.1%). In conclusion, cardiac output can be precisely and accurately determined with constant infusion transpulmonary thermodilution in exercising humans....

  11. Liver haemodynamics and function in alcoholic cirrhosis. Relation to testosterone treatment and ethanol consumption

    DEFF Research Database (Denmark)

    Gluud, C; Henriksen, J H

    1987-01-01

    group, a significant change in median values of portal pressure (-23%, n = 34, P less than 0.005), hepatic blood flow (-22%, n = 28, P less than 0.001), indocyanine green clearance (+16%, n = 29, P less than 0.01), and galactose elimination capacity (+8%, n = 31, P less than 0.05) was observed. However...

  12. Detection of rheumatoid arthritis in humans by fluorescence imaging

    Science.gov (United States)

    Ebert, Bernd; Dziekan, Thomas; Weissbach, Carmen; Mahler, Marianne; Schirner, Michael; Berliner, Birgitt; Bauer, Daniel; Voigt, Jan; Berliner, Michael; Bahner, Malte L.; Macdonald, Rainer

    2010-02-01

    The blood pool agent indo-cyanine green (ICG) has been investigated in a prospective clinical study for detection of rheumatoid arthritis using fluorescence imaging. Temporal behavior as well as spatial distribution of fluorescence intensity are suited to differentiate healthy and inflamed finger joints after i.v. injection of an ICG bolus.

  13. Nanocolloidal albumin-IRDye 800CW: A near-infrared fluorescent tracer with optimal retention in the sentinel lymph node

    NARCIS (Netherlands)

    Heuveling, Derrek A.; Visser, Gerard W.M.; De Groot, Mattijs; De Boer, Johannes F.; Baclayon, Marian; Roos, Wouter H.; Wuite, Gijs J.L.; Leemans, C. René; De Bree, Remco; Van Dongen, Guus A.M.S.

    2012-01-01

    Purpose: At present, the only approved fluorescent tracer for clinical near-infrared fluorescence-guided sentinel node (SN) detection is indocyanine green (ICG), but the use of this tracer is limited due to its poor retention in the SN resulting in the detection of higher tier nodes. We describe the

  14. Nanocolloidal albumin-IRDye 800CW: a near-infrared fluorescent tracer with optimal retention in the sentinel lymph node

    NARCIS (Netherlands)

    Heuveling, D.A.; Visser, G.W.M.; de Groot, M.; de Boer, J.F.; Salumbides - Baclayon, M.; Roos, W.H.; Wuite, G.J.L.; Leemans, C.R.; de Bree, R.; van Dongen, G.A.M.S.

    2012-01-01

    Purpose: At present, the only approved fluorescent tracer for clinical near-infrared fluorescence-guided sentinel node (SN) detection is indocyanine green (ICG), but the use of this tracer is limited due to its poor retention in the SN resulting in the detection of higher tier nodes. We describe the

  15. Alanine metabolism in acute falciparum malaria

    NARCIS (Netherlands)

    Pukrittayakamee, S.; Krishna, S.; ter Kuile, F.; Wilaiwan, O.; Williamson, D. H.; White, N. J.

    2002-01-01

    We investigated the integrity of the gluconeogenic pathway in severe malaria using alanine metabolism as a measure. Alanine disposition and liver blood flow, assessed by indocyanine green (ICG) clearance, were measured simultaneously in 10 patients with falciparum malaria (six severe and four

  16. Bilateral Dome-Shaped Macula with Serous Macular Detachment in a Child

    OpenAIRE

    Cebeci, Zafer; Kir, Nur

    2015-01-01

    Dome-shaped macula is a structural disorder and optical coherence tomography (OCT) helps us to confirm macular convexity. We describe the first case of bilateral dome-shaped macula in an 8-year-old boy with subretinal fluid. The patient was diagnosed using spectral-domain OCT and received indocyanine green angiography-guided half-fluence photodynamic therapy as treatment.

  17. Advanced detection strategies for ultrasound contrast agents

    NARCIS (Netherlands)

    J.M.G. Borsboom (Jerome)

    2005-01-01

    markdownabstract__Abstract__ Ultrasound contrast agent was discovered serendipitously by Gramiak and Shah in I968 when they injected indocyanine green dye into the heart and observed increased echogenicity of the blood containing the dye. Small cavitation bubbles that were formed upon

  18. Fluoxetine induces vasodilatation of cerebral arterioles by co-modulating NO/muscarinic signalling

    Science.gov (United States)

    Ofek, Keren; Schoknecht, Karl; Melamed-Book, Naomi; Heinemann, Uwe; Friedman, Alon; Soreq, Hermona

    2012-01-01

    Ischaemic stroke patients treated with Selective Serotonin Reuptake Inhibitors (SSRI) show improved motor, cognitive and executive functions, but the underlying mechanism(s) are incompletely understood. Here, we report that cerebral arterioles in the rat brain superfused with therapeutically effective doses of the SSRI fluoxetine showed consistent, dose-dependent vasodilatation (by 1.2 to 1.6-fold), suppressible by muscarinic and nitric oxide synthase (NOS) antagonists [atropine, NG-nitro-l-arginine methyl ester (l-NAME)] but resistant to nicotinic and serotoninergic antagonists (mecamylamine, methylsergide). Fluoxetine administered 10–30 min. following experimental vascular photo-thrombosis increased arterial diameter (1.3–1.6), inducing partial, but lasting reperfusion of the ischaemic brain. In brain endothelial b.End.3 cells, fluoxetine induced rapid muscarinic receptor-dependent increases in intracellular [Ca2+] and promoted albumin- and eNOS-dependent nitric oxide (NO) production and HSP90 interaction. In vitro, fluoxetine suppressed recombinant human acetylcholinesterase (rhAChE) activity only in the presence of albumin. That fluoxetine induces vasodilatation of cerebral arterioles suggests co-promotion of endothelial muscarinic and nitric oxide signalling, facilitated by albumin-dependent inhibition of serum AChE. PMID:22697296

  19. Pretreatment with Shuanghe-Tang Extract Attenuates Postischemic Brain Injury and Edema in a Mouse Model of Stroke: An Analysis of Medicinal Herbs Listed in Dongui Bogam

    Directory of Open Access Journals (Sweden)

    Min Jae Kim

    2018-01-01

    Full Text Available Aim. Although stroke is among the leading causes of death and long-term disability, there are few effective treatments for limiting the severity of neurological sequelae. We evaluated the effects of 29 medicinal herbs listed in the Pung chapter of the 17th century Korean medical text Dongui Bogam on stroke symptoms in a mouse model of cerebral ischemia. Methods. Focal cerebral ischemia was induced via photothrombosis. Infarct volume, brain edema, and neurological deficits were evaluated. Immunofluorescence staining for tight junction proteins and aquaporin 4 (AQP4 was performed following ischemic injury. Results. Based on our initial findings, we examined the effects of two prescriptions in which the candidate herbs comprised more than 60% of the total formula: Shuanghe-tang and Zengsunsiwu-tang. Pretreatment with Shuanghe-tang significantly reduced infarct volume, decreased blood-brain barrier (BBB breakdown, attenuated edema, and improved neurological and motor functions in a dose-dependent manner (30, 100, and 300 mg/kg, while no such effects were observed in mice pretreated with Zengsunsiwu-tang. Immunohistochemical analysis revealed significant increases in ipsilateral occludin and zonula occludens 1 (ZO-1 expression in Shuanghe-tang-pretreated mice, as well as increased AQP4 immunofluorescence. Conclusions. These results indicate that Shuanghe-tang may protect against brain injury and promote recovery of neurological function following ischemia.

  20. Biomcompatible gold nanorods conjugated with photosensitizers assisted for photostability and photodestructive ability

    Science.gov (United States)

    Kuo, Wen-Shuo; Chen, Shean-Jen

    2012-02-01

    Light-exposure-mediated higher temperatures that markedly accelerate the degradation of indocyanine green (ICG) in aqueous solutions by thermal decomposition have been a serious medical problem. In this work, we present the example of using gold nanorods (Au NRs) simultaneously serving as photodynamic and photothermal agents to destroy malignant cells. Au NRs were successfully conjugated with hydrophilic photosensitizer, indocyanine green (ICG), to achieve photodynamic therapy (PDT) and photothermal therapy (PTT). We also demonstrated that Au NRs conjugated with ICG displayed high chemical stability and acted as a promising diagnostic probe. Due to its stability even via higher temperatures mediated by laser irradiation, the combination of PDT and PTT proved to be efficiently killing cancer cells as compared to PDT or PTT treatment alone and enhanced the effectiveness of photodestruction and was demonstrated to enhance its photostability.

  1. Thermal damage control of dye-assisted laser tissue welding: effect of dye concentration

    Science.gov (United States)

    Xie, Hua; Buckley, Lisa A.; Prahl, Scott A.; Shaffer, Brian S.; Gregory, Kenton W.

    2001-05-01

    Successful laser-assisted tissue welding was implemented to provide proper weld strength with minimized tissue thermal injury. We investigated and compared the weld strengths and morphologic changes in porcine small intestinal submucose (SIS) and porcine ureteral tissues with various concentration of indocyanine green (ICG) and with a solid albumin sheet. The study showed that the tissues were welded at lower ICG concentration (0.05 mM) with minimized tissue thermal damage using an 800-nm wavelength diode laser.

  2. Experimental diode laser-assisted microvascular anastomosis.

    Science.gov (United States)

    Reali, U M; Gelli, R; Giannotti, V; Gori, F; Pratesi, R; Pini, R

    1993-05-01

    An experimental study to evaluate a diode-laser approach to microvascular end-to-end anastomoses is reported. Studies were carried out on the femoral arteries and veins of Wistar rats, and effective welding of vessel tissue was obtained at low laser power, by enhancing laser absorption with indocyanine green (Cardio-green) solution. The histologic and surgical effects of this laser technique were examined and compared with those of conventional microvascular sutured anastomoses.

  3. Erythrocyte-derived nano-probes functionalized with antibodies for targeted near infrared fluorescence imaging of cancer cells

    OpenAIRE

    Anvari, Bahman; Mac, Jenny T.; Nunez, Vicente; Burns, Joshua M.; Guerrero, Yadir A.

    2016-01-01

    Constructs derived from mammalian cells are emerging as a new generation of nano-scale platforms for clinical imaging applications. Herein, we report successful engineering of hybrid nano-structures composed of erythrocyte-derived membranes doped with FDA-approved near infrared (NIR) chromophore, indocyanine green (ICG), and surface-functionalized with antibodies to achieve molecular targeting. We demonstrate that these constructs can be used for targeted imaging of cancer cells in vitro. The...

  4. Positioning Vascularized Composite Allotransplantation within the Spectrum of Transplantation

    Science.gov (United States)

    2016-10-01

    infrared imaging of ICG dye to study blood perfusion and lymphatic drainage in our hand transplant patients. We are extending our studies of vessel...IRB as well as HRPO to perform intradermal injections of indocyanine green (ICG) and infrared camera imaging using the LUNA fluorescence angiography...animals prior to transplantation. As shown in figure 13, the bedding was removed from the cages and replaced with a soft rubber mat that the animals

  5. The use of near-infrared fluorescence imaging in endocrine surgical procedures.

    Science.gov (United States)

    Kahramangil, Bora; Berber, Eren

    2017-06-01

    Near-infrared fluorescence imaging in endocrine surgery is a new, yet highly investigated area. It involves indocyanine green use as well as parathyroid autofluorescence. Several groups have described their technique and reported on the observed utility. However, there is no consensus on technical details. Furthermore, the correlation between intraoperative findings and postoperative outcomes is unclear. With this study, we aim to review the current literature on fluorescence imaging and share our insights on technical details. © 2017 Wiley Periodicals, Inc.

  6. Plasma catecholamine level and portal venous pressure as guides to prognosis in patients with cirrhosis

    DEFF Research Database (Denmark)

    Tage-Jensen, U; Henriksen, Jens Henrik; Christensen, E

    1988-01-01

    clinical and biochemical variables and survival. Forty-seven (58%) of the patients died during the follow-up period. Univariate analysis showed that plasma noradrenaline and adrenaline concentrations, portal pressure, indocyanine green clearance, serum sodium, bilirubin, and albumin concentrations......, and the presence of ascites or cardiovascular disease were of significant prognostic value. In a multivariate analysis (Cox regression model), plasma noradrenaline concentration, portal pressure, serum bilirubin concentration, and the presence of ascites and cardiovascular disease remained significant independent...

  7. Adaptive optics scanning laser ophthalmoscopy in fundus imaging, a review and update

    OpenAIRE

    Zhang, Bing; Li, Ni; Kang, Jie; He, Yi; Chen, Xiao-Ming

    2017-01-01

    Adaptive optics scanning laser ophthalmoscopy (AO-SLO) has been a promising technique in funds imaging with growing popularity. This review firstly gives a brief history of adaptive optics (AO) and AO-SLO. Then it compares AO-SLO with conventional imaging methods (fundus fluorescein angiography, fundus autofluorescence, indocyanine green angiography and optical coherence tomography) and other AO techniques (adaptive optics flood-illumination ophthalmoscopy and adaptive optics optical coherenc...

  8. Multi-Modal Imaging in a Mouse Model of Orthotopic Lung Cancer

    OpenAIRE

    Patel, Priya; Kato, Tatsuya; Ujiie, Hideki; Wada, Hironobu; Lee, Daiyoon; Hu, Hsin-pei; Hirohashi, Kentaro; Ahn, Jin Young; Zheng, Jinzi; Yasufuku, Kazuhiro

    2016-01-01

    Background Investigation of CF800, a novel PEGylated nano-liposomal imaging agent containing indocyanine green (ICG) and iohexol, for real-time near infrared (NIR) fluorescence and computed tomography (CT) image-guided surgery in an orthotopic lung cancer model in nude mice. Methods CF800 was intravenously administered into 13 mice bearing the H460 orthotopic human lung cancer. At 48 h post-injection (peak imaging agent accumulation time point), ex vivo NIR and CT imaging was performed. A cli...

  9. Imaging of Lymph Flow in Breast Cancer Patients after Microdose Administration of a Near-Infrared Fluorophore: Feasibility Study1

    Science.gov (United States)

    Sevick-Muraca, Eva M.; Sharma, Ruchi; Rasmussen, John C.; Marshall, Milton V.; Wendt, Juliet A.; Pham, Hoang Q.; Bonefas, Elizabeth; Houston, Jessica P.; Sampath, Lakshmi; Adams, Kristen E.; Blanchard, Darlene Kay; Fisher, Ronald E.; Chiang, Stephen B.; Elledge, Richard; Mawad, Michel E.

    2011-01-01

    Purpose To prospectively demonstrate the feasibility of using indocyanine green, a near-infrared (NIR) fluorophore at the minimum dose needed for noninvasive optical imaging of lymph nodes (LNs) in breast cancer patients undergoing sentinel lymph node mapping (SLNM). Materials and Methods Informed consent was obtained from 24 women (age range, 30–85 years) who received intradermal subcutaneous injections of 0.31–100 μg indocyanine green in the breast in this IRB-approved, HIPAA-compliant, dose escalation study to find the minimum microdose for imaging. The breast, axilla, and sternum were illuminated with NIR light and the fluorescence generated in the tissue was collected with an NIR-sensitive intensified charged-coupled device. Lymphoscintigraphy was also performed. Resected LNs were evaluated for the presence of radioactivity, blue dye accumulation, and fluorescence. The associations between the resected LNs that were fluorescent and (a) the time elapsed between NIR fluorophore administration and resection and (b) the dosage of NIR fluorophores were tested with the Spearman rank and Pearson product moment correlation tests, respectively. Results Lymph imaging consistently failed with indocyanine green microdosages between 0.31 and 0.77 μg. When indocyanine green dosages were 10 μg or higher, lymph drainage pathways from the injection site to LNs were imaged in eight of nine women; lymph propulsion was observed in seven of those eight. When propulsion in the breast and axilla regions was present, the mean apparent velocities ranged from 0.08 to 0.32 cm/sec, the time elapsed between “packets” of propelled fluid varied from 14 to 92 seconds. In patients who received 10 μg of indocyanine green or more, a weak negative correlation between the fluorescence status of resected LNs and the time between NIR fluorophore administration and LN resection was found. No statistical association was found between the fluorescence status of resected LNs and the dose of

  10. Nitric oxide synthase-I containing cortical interneurons co-express antioxidative enzymes and anti-apoptotic Bcl-2 following focal ischemia: evidence for direct and indirect mechanisms towards their resistance to neuropathology.

    Science.gov (United States)

    Bidmon, H J; Emde, B; Kowalski, T; Schmitt, M; Mayer, B; Kato, K; Asayama, K; Witte, O W; Zilles, K

    2001-09-01

    Neuronal nitric oxide-I is constitutively expressed in approximately 2% of cortical interneurons and is co-localized with gamma-amino butric acid, somatostatin or neuropeptide Y. These interneurons additionally express high amounts of glutamate receptors which mediate the glutamate-induced hyperexcitation following cerebral injury, under these conditions nitric oxide production increases contributing to a potentiation of oxidative stress. However, perilesional nitric oxide synthase-I containing neurons are known to be resistant to ischemic and excitotoxic injury. In vitro studies show that nitrosonium and nitroxyl ions inactivate N-methyl-D-aspartate receptors, resulting in neuroprotection. The question remains of how these cells are protected against their own high intracellular nitric oxide production after activation. In this study, we investigated immunocytochemically nitric oxide synthase-I containing cortical neurons in rats after unilateral, cortical photothrombosis. In this model of focal ischemia, perilesional, constitutively nitric oxide synthase-I containing neurons survived and co-expressed antioxidative enzymes, such as manganese- and copper-zinc-dependent superoxide dismutases, heme oxygenase-2 and cytosolic glutathione peroxidase. This enhanced antioxidant expression was accompanied by a strong perinuclear presence of the antiapoptotic Bcl-2 protein. No colocalization was detectable with upregulated heme oxygenase-1 in glia and the superoxide and prostaglandin G(2)-producing cyclooxygenase-2 in neurons. These results suggest that nitric oxide synthase-I containing interneurons are protected against intracellular oxidative damage and apoptosis by Bcl-2 and several potent antioxidative enzymes. Since nitric oxide synthase-I positive neurons do not express superoxide-producing enzymes such as cyclooxygenase-1, xanthine oxidase and cyclooxygenase-2 in response to injury, this may additionally contribute to their resistance by reducing their internal

  11. Enriched housing enhances recovery of limb placement ability and reduces aggrecan-containing perineuronal nets in the rat somatosensory cortex after experimental stroke.

    Directory of Open Access Journals (Sweden)

    Alexandre Madinier

    Full Text Available Stroke causes life long disabilities where few therapeutic options are available. Using electrical and magnetic stimulation of the brain and physical rehabilitation, recovery of brain function can be enhanced even late after stroke. Animal models support this notion, and housing rodents in an enriched environment (EE several days after experimental stroke stimulates lost brain function by multisensory mechanisms. We studied the dynamics of functional recovery of rats with a lesion to the fore and hind limb motor areas induced by photothrombosis (PT, and with subsequent housing in either standard (STD or EE. In this model, skilled motor function is not significantly enhanced by enriched housing, while the speed of recovery of sensori-motor function substantially improves over the 9-week study period. In particular, this stroke lesion completely obliterates the fore and hind limb placing ability when visual and whisker guidance is prevented, a deficit that persists for up to 9 weeks of recovery, but that is markedly restored within 2 weeks by enriched housing. Enriched housing after stroke also leads to a significant loss of perineuronal net (PNN immunoreactivity; detection of aggrecan protein backbone with AB1031 antibody was decreased by 13-22%, and labelling of a glycan moiety of aggrecan with Cat-315 antibody was reduced by 25-30% in the peri-infarct area and in the somatosensory cortex, respectively. The majority of these cells are parvalbumin/GABA inhibitory interneurons that are important in sensori-information processing. We conclude that damage to the fore and hind limb motor areas provides a model of loss of limb placing response without visual guidance, a deficit also seen in more than 50% of stroke patients. This loss is amenable to recovery induced by multiple sensory stimulation and correlates with a decrease in aggrecan-containing PNNs around inhibitory interneurons. Modulating the PNN structure after ischemic damage may provide new

  12. Mechanism of the beneficial effects of ATP-MgCl2 following trauma-hemorrhage and resuscitation: downregulation of inflammatory cytokine (TNF, IL-6) release.

    Science.gov (United States)

    Wang, P; Ba, Z F; Morrison, M H; Ayala, A; Dean, R E; Chaudry, I H

    1992-04-01

    Although ATP-MgCl2 improves hepatocellular function in a nonheparinized model of trauma-hemorrhage and crystalloid resuscitation, it remains unknown whether the beneficial effects of this agent are due to downregulation of the release of the inflammatory cytokines, tumor necrosis factor (TNF), and interleukin-6 (IL-6) under those conditions. To study this, rats underwent a 5-cm laparotomy (i.e., trauma induced) and were bled to and maintained at a mean arterial pressure of 40 mm Hg until 40% of maximum bleedout volume was returned in the form of Ringer's lactate (RL). The animals were then resuscitated with four times the volume of shed blood with RL over 60 min. ATP-MgCl2 (50 mumoles/kg body weight each) or an equivalent volume of normal saline was infused intravenously for 95 min. This infusion was started during the last 15 min of RL resuscitation. Plasma levels of TNF and IL-6 were measured at 1.5 hr after the completion of resuscitation by cytokine-dependent cellular assays. Hepatic blood flow was determined by in vivo indocyanine green clearance (corrected by hepatic extraction ratio for indocyanine green), radioactive microspheres, and [3H]-galactose clearance techniques. The results indicate that the levels of circulating TNF and IL-6 increased significantly in the hemorrhaged-resuscitated animals. ATP-MgCl2 treatment, however, markedly decreased the synthesis and/or release of these cytokines to levels similar to the sham group. The markedly decreased hepatic blood flow (as determined by three different methods) and hepatic extraction ratio for indocyanine green were also restored by ATP-MgCl2 treatment.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Administration of progesterone after trauma and hemorrhagic shock prevents hepatocellular injury.

    Science.gov (United States)

    Kuebler, Joachim F; Yokoyama, Yukihiro; Jarrar, Doraid; Toth, Balazs; Rue, Loring W; Bland, Kirby I; Wang, Ping; Chaudry, Irshad H

    2003-07-01

    Administration of a single dose of progesterone following trauma and hemorrhage in progesterone-deficient rats would ameliorate the inflammatory response and hepatocellular damage. A university laboratory. Ovariectomized female Sprague-Dawley rats (250-350 g; Charles River Laboratories, Wilmington, Mass) underwent a 5-cm midline laparotomy (ie, induction of soft tissue trauma), were bled to a mean arterial blood pressure of 35 mm Hg for about 90 minutes, and then were resuscitated using Ringer lactate solution. Progesterone (25 mg/kg of body weight) or vehicle was administered subcutaneously at the end of resuscitation. In additional animals, Kupffer cells were isolated following trauma, hemorrhage, and resuscitation and treated in vitro with progesterone, lipopolysaccharide, or both. Six hours following resuscitation, plasma tumor necrosis factor alpha (TNF-alpha) and interleukin 6 (IL-6) levels and liver myeloperoxidase activity were determined. Hepatocellular function (maximum velocity of indocyanine green clearance [Vmax] and the efficiency of the active transport or Michaelis-Menten constant [Km]) and plasma levels of transaminases were measured 20 hours after resuscitation. Kupffer cell IL-6 and TNF-alpha production were assessed. Plasma levels of TNF-alpha, IL-6, aspartate aminotransferase, and alanine aminotransferase, as well as hepatic myeloperoxidase activity were increased, whereas indocyanine green clearance was depressed in vehicle-treated rats following trauma-hemorrhage. Animals treated with progesterone showed significantly reduced levels of the TNF-alpha, IL-6, and transaminases as well as reduced myeloperoxidase activity in the liver. Progesterone-treated animals showed increased Vmax and Kmax values for indocyanine green. In vitro treatment of Kupffer cells with progesterone decreased TNF-alpha production but did not affect the production of IL-6. Progesterone administration following trauma-hemorrhage ameliorates the proinflammatory response

  14. A new technique for the closure of the lens capsule by laser welding.

    Science.gov (United States)

    Pini, Roberto; Rossi, Francesca; Menabuoni, Luca; Lenzetti, Ivo; Yoo, Sonia; Parel, Jean-Marie

    2008-01-01

    A new method is presented for the closure of the lens capsule based on laser welding of suitably prepared patches of anterior capsular tissue. Experiments were performed in freshly enucleated porcine eyes. The patches were previously stained with a solution of indocyanine green in sterile water and then welded on the recipient capsule by means of diode laser radiation at 810 nm. The welded tissue revealed mechanical properties comparable to those of healthy tissue. This technique is proposed to repair capsular breaks and to provide the closure of the capsulorhexis in lens refilling procedures.

  15. Prolonged Q-T(c) interval in mild portal hypertensive cirrhosis

    DEFF Research Database (Denmark)

    Ytting, Henriette; Henriksen, Jens Henrik; Fuglsang, Stefan

    2005-01-01

    BACKGROUND/AIMS: The Q-T(c) interval is prolonged in a substantial fraction of patients with cirrhosis, thus indicating delayed repolarisation. However, no information is available in mild portal hypertensive patients. We therefore determined the Q-T(c) interval in cirrhotic patients with hepatic...... venous pressure gradient (HVPG) portal hypertension (HVPG> or = 12 mmHg) and controls without liver disease. RESULTS......), values which are significantly above that of the controls (0.410 s(1/2), P portal hypertensive group, the Q-T(c) interval was inversely related to indicators of liver function, such as indocyanine green clearance (r = -0.34, P

  16. Plant virus-resembling optical nano-materials conjugated with anti-EGFR for targeted cancer imaging

    Science.gov (United States)

    Gupta, Sharad; Wilder, Hailey; Rao, A. L. N.; Vullev, V. I.; Anvari, Bahman

    2012-03-01

    We recently reported the construction of a new type of optically active nano-particles composed of genome-depleted plant infecting brome mosaic virus (BMV) doped with indocyanine green (ICG), an FDA-approved chromophore . We refer to these constructs as optical viral ghosts (OVGs) since only the capsid protein (CP) subunits of BMV remain to encapsulate ICG. Herein, we covalently conjugated the surface of OVGs with anti-epidermal growth factor receptors (anti-EGFR) to target cancerous human bronchial epithelial cells (C-HBECs) in-vitro. Our preliminary results demonstrate the utility of conjugated OVGs for targeted imaging of cancer cells.

  17. OPTICAL COHERENCE TOMOGRAPHY OF ADIPOSE TISSUE AT PHOTODYNAMIC/PHOTOTHERMAL TREATMENT IN VITRO

    Directory of Open Access Journals (Sweden)

    IRINA YU. YANINA

    2013-04-01

    Full Text Available Temporal changes in structure and refractive-index distribution of adipose tissue at photodynamic/photothermal treatment were studied with OCT in vitro. Ethanol–water solutions of indocyanine green (ICG and brilliant green (BG were used for fat tissue staining. CW laser diode (808 nm and LED light source (442 and 597 nm were used for irradiation of stained tissue slices. The data received supporting the hypothesis that photodynamic/photothermal treatment, induces fat cell lipolysis during a certain period of time after light exposure.

  18. Arterial hypoxaemia in cirrhosis: fact or fiction?

    DEFF Research Database (Denmark)

    Møller, S; Hillingsø, J; Christensen, E

    1998-01-01

    characteristics. PATIENTS: One hundred and forty two patients with cirrhosis without significant hepatic encephalopathy (grades 0-I) (41 patients in Child class A, 57 in class B, and 44 in class C) and 21 patients with hepatic encephalopathy. RESULTS: Mean Po2 in kPa was 11.3 in Child class A, 10.8 in class B, 10...... resistance, and a low indocyanine green clearance (p hepatic dysfunction. Arterial hypoxaemia in patients with cirrhosis of differing.......6 in class C, and 10.6 in patients with encephalopathy (p C, and in patients with encephalopathy (p

  19. Arterial hypoxaemia in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Hillingsø, Jens; Christensen, E

    1998-01-01

    characteristics. PATIENTS: One hundred and forty two patients with cirrhosis without significant hepatic encephalopathy (grades 0-I) (41 patients in Child class A, 57 in class B, and 44 in class C) and 21 patients with hepatic encephalopathy. RESULTS: Mean Po2 in kPa was 11.3 in Child class A, 10.8 in class B, 10...... resistance, and a low indocyanine green clearance (p hepatic dysfunction. Arterial hypoxaemia in patients with cirrhosis of differing.......6 in class C, and 10.6 in patients with encephalopathy (p C, and in patients with encephalopathy (p

  20. Ultra-widefield fluorescein angiography reveals retinal phlebitis in Susac's syndrome.

    Science.gov (United States)

    Klufas, Michael A; Dinkin, Marc J; Bhaleeya, Swetangi D; Chapman, Kristin O; Riley, Claire S; Kiss, Szilárd

    2014-01-01

    A 23-year-old woman with history of headaches and auditory changes presented with acute-onset visual field loss in the right eye. The combination of multiple retinal branch artery occlusions of the right eye on funduscopic examination, characteristic white matter lesions in the corpus callosum on magnetic resonance imaging, and hearing loss on audiometric testing led to a diagnosis of Susac's syndrome. Ultra-widefield fluorescein angiography revealed involvement of the retinal veins, which has not been previously reported with this condition. Additionally, ultra-widefield indocyanine green angiography demonstrated changes in the choroidal circulation, which are controversial in this syndrome. Copyright 2014, SLACK Incorporated.

  1. Detection of rheumatoid arthritis by evaluation of normalized variances of fluorescence time correlation functions

    Science.gov (United States)

    Dziekan, Thomas; Weissbach, Carmen; Voigt, Jan; Ebert, Bernd; MacDonald, Rainer; Bahner, Malte L.; Mahler, Marianne; Schirner, Michael; Berliner, Michael; Berliner, Birgitt; Osel, Jens; Osel, Ilka

    2011-07-01

    Fluorescence imaging using the dye indocyanine green as a contrast agent was investigated in a prospective clinical study for the detection of rheumatoid arthritis. Normalized variances of correlated time series of fluorescence intensities describing the bolus kinetics of the contrast agent in certain regions of interest were analyzed to differentiate healthy from inflamed finger joints. These values are determined using a robust, parameter-free algorithm. We found that the normalized variance of correlation functions improves the differentiation between healthy joints of volunteers and joints with rheumatoid arthritis of patients by about 10% compared to, e.g., ratios of areas under the curves of raw data.

  2. Atypical presentation of multiple evanescent white dot syndrome (MEWDS).

    Science.gov (United States)

    Yenerel, Nursal Melda; Kucumen, Beril; Gorgun, Ebru; Dinc, Umut Asli

    2008-01-01

    To present fundus autofluorescence (FAF), indocyanine green angiography (ICGA), and microperimetry (MP) findings of a patient with multiple evanescent white dot syndrome (MEWDS). Observational case report. A 30-year-old woman with blurry vision was referred for evaluation. Fundus examination revealed only foveal granularity. FAF showed hyperautofluorescent spots, although they were not visible clinically. On ICGA, matching areas were hypofluorescent. Microperimetry revealed mean sensitivity decrease. The resolution of the symptoms was followed by disappearance of these spots in FAF and ICGA and increase of mean macular sensitivity in MP. FAF is a noninvasive imaging technique that might help in the differential diagnosis of chorioretinal pathologies.

  3. Combined inhibition of nitric oxide and prostaglandins reduces human skeletal muscle blood flow during exercise

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Langberg, Henning; Gemmer, Carsten

    2002-01-01

    The vascular endothelium is an important mediator of tissue vasodilatation, yet the role of the specific substances, nitric oxide (NO) and prostaglandins (PG), in mediating the large increases in muscle perfusion during exercise in humans is unclear. Quadriceps microvascular blood flow......, respectively (P exercise in humans. These findings demonstrate an important synergistic role of NO and PG for skeletal muscle vasodilatation and hyperaemia during muscular contraction....... was quantified by near infrared spectroscopy and indocyanine green in six healthy humans during dynamic knee extension exercise with and without combined pharmacological inhibition of NO synthase (NOS) and PG by L-NAME and indomethacin, respectively. Microdialysis was applied to determine interstitial release...

  4. Prognostic indicators in alcoholic cirrhotic men

    DEFF Research Database (Denmark)

    Gluud, C; Henriksen, Jens Henrik Sahl; Nielsen, G

    1988-01-01

    as wedged minus free hepatic vein pressure, and median pressure was 14 mm Hg (range = 3 to 26 mm Hg). Fourteen of 31 patients (45%) had esophageal varices at upper gastrointestinal endoscopy (the size being considered large in nine patients). During follow-up (median = 31 months; range = 2 to 51 months), 12...... patients (21%) developed variceal hemorrhage. Applying Cox's regression analysis, information about previous variceal bleeding (p = 0.0046), large varices at endoscopy (p = 0.012), hepatic vein pressure gradient (p = 0.0056) and indocyanine green clearance (p = 0.038) all contained significant prognostic...

  5. Calibrating the photo-thermal response of magneto-fluorescent gold nanoshells.

    Science.gov (United States)

    Biswal, Nrusingh C; Ayala-Orzoco, Ciceron; Halas, Naomi J; Joshi, Amit

    2011-01-01

    We report the photothermal response and Near Infrared (NIR) imaging sensitivities of magneto-fluorescent silica core gold nanocomplexes designed for molecular image guided thermal therapy of cancer. Approximately 160 nm Silica core gold nanoshells were designed to provide NIR fluorescent and Magnetic Resonance (MR) contrast by incorporating FDA approved dye indocyanine green (ICG) and iron-oxide within an outer silica epilayer. The imaging and therapeutic sensitivity, and the stability of fluorescence contrast for 12 microliters of suspension (containing approximately 7.9 × 10(8) or 1.3 femtoMole nanoshells) buried at depths of 2-8 mm in tissue mimicking scattering media is reported.

  6. Organic Alternatives to Quantum Dots for Intraoperative Near-Infrared Fluorescent Sentinel Lymph Node Mapping

    Directory of Open Access Journals (Sweden)

    Shunsuke Ohnishi

    2005-07-01

    Full Text Available Intraoperative near-infrared (NIR fluorescence imaging provides the surgeon with real-time image guidance during cancer and other surgeries. We have previously reported the use of NIR fluorescent quantum dots (QDs for sentinel lymph node (SLN mapping. However, because of concerns over potential toxicity, organic alternatives to QDs will be required for initial clinical studies. We describe a family of 800 nm organic heptamethine indocyanine-based contrast agents for SLN mapping spanning a spectrum from 775 Da small molecules to 7 MDa nanocolloids. We provide a detailed characterization of the optical and physical properties of these contrast agents and discuss the advantages and disadvantages of each. We present robust methods for the covalent conjugation, purification, and characterization of proteins with tetra-sulfonated heptamethine indocyanines, including mass spectroscopic site mapping of highly substituted molecules. One contrast agent, NIR fluorescent human serum albumin (HSA800, emerged as the molecule with the best overall performance with respect to entry to lymphatics, flow to the SLN, retention in the SLN, fluorescence yield and reproducibility. This preclinical study, performed on large animals approaching the size of humans, should serve as a foundation for future clinical studies.

  7. An update on the ocular phenotype in patients with pseudoxanthoma elasticum

    Directory of Open Access Journals (Sweden)

    Martin eGliem

    2013-04-01

    Full Text Available Pseudoxanthoma elasticum (PXE is an inherited multi-system disorder characterized by ectopic mineralization and fragmentation of elastic fibres in the skin, the elastic laminae of blood vessels and Bruch membrane in the eye. Biallelic mutations in the ABC transporter gene ABCC6 on chromosome 16 are responsible for the disease.The pathophysiology is incompletely understood. However, there is consent that a metabolic alteration leads to dysfunction in extracellular calcium homeostasis and subsequent calcification of connective tissues rich in elastic fibres. This review summarizes and aims at explaining the variety of phenotypic ocular findings in patients with PXE. Specialised imaging techniques including white light fundus photography, blue light autofluorescence, near-infrared confocal reflectance imaging, high resolution optical coherence tomography, fluorescein and indocyanin green angiography have revealed characteristic lesions at the ocular fundus of PXE patients. These include the classic signs of angioid streaks, peau d’orange, comet lesions and choroidal neovascularisations (CNV, but also the more recently recognised features such as chorioretinal atrophy, subretinal fluid independent from CNV, pattern dystrophy-like changes, debris accumulation under the retinal pigment epithelium, and a decreased fluorescence on late phase indocyanine green angiography.

  8. Failure to Integrate Quantitative Measurement Methods of Ocular Inflammation Hampers Clinical Practice and Trials on New Therapies for Posterior Uveitis.

    Science.gov (United States)

    Herbort, Carl P; Tugal-Tutkun, Ilknur; Neri, Piergiorgio; Pavésio, Carlos; Onal, Sumru; LeHoang, Phuc

    2017-05-01

    Uveitis is one of the fields in ophthalmology where a tremendous evolution took place in the past 25 years. Not only did we gain access to more efficient, more targeted, and better tolerated therapies, but also in parallel precise and quantitative measurement methods developed allowing the clinician to evaluate these therapies and adjust therapeutic intervention with a high degree of precision. Objective and quantitative measurement of the global level of intraocular inflammation became possible for most inflammatory diseases with direct or spill-over anterior chamber inflammation, thanks to laser flare photometry. The amount of retinal inflammation could be quantified by using fluorescein angiography to score retinal angiographic signs. Indocyanine green angiography gave imaging insight into the hitherto inaccessible choroidal compartment, rendering possible the quantification of choroiditis by scoring indocyanine green angiographic signs. Optical coherence tomography has enabled measurement and objective monitoring of retinal and choroidal thickness. This multimodal quantitative appraisal of intraocular inflammation represents an exquisite security in monitoring uveitis. What is enigmatic, however, is the slow pace with which these improvements are integrated in some areas. What is even more difficult to understand is the fact that clinical trials to assess new therapeutic agents still mostly rely on subjective parameters such as clinical evaluation of vitreous haze as a main endpoint; whereas a whole array of precise, quantitative, and objective modalities are available for the design of clinical studies. The scope of this work was to review the quantitative investigations that improved the management of uveitis in the past 2-3 decades.

  9. Allgöwer-Donati Versus Vertical Mattress Suture Technique Impact on Perfusion in Ankle Fracture Surgery: A Randomized Clinical Trial Using Intraoperative Angiography.

    Science.gov (United States)

    Shannon, Steven F; Houdek, Matthew T; Wyles, Cody C; Yuan, Brandon J; Cross, William W; Cass, Joseph R; Sems, Stephen A

    2017-02-01

    The purpose of this study was to evaluate which primary wound closure technique for ankle fractures affords the most robust perfusion as measured by laser-assisted indocyanine green angiography: Allgöwer-Donati or vertical mattress. Prospective, randomized. Level 1 Academic Trauma Center. Thirty patients undergoing open reduction internal fixation for ankle fractures were prospectively randomized to Allgöwer-Donati (n = 15) or vertical mattress (n = 15) closure. Demographics were similar for both cohorts with respect to age, sex, body mass index, surgical timing, and OTA/AO fracture classification. Skin perfusion (mean incision perfusion and mean perfusion impairment) was quantified in fluorescence units with laser-assisted indocyanine green angiography along the lateral incision as well as anterior and posterior to the incision at 30 separate locations. Minimum follow-up was 3 months with a mean follow-up 4.7 months. Allgöwer-Donati enabled superior perfusion compared with the vertical mattress suture technique. Mean incision perfusion for Allgöwer-Donati was 51 (SD = 13) and for vertical mattress was 28 (SD = 10, P ankle fractures. Theoretically, this may enhance soft tissue healing and decrease the risk of wound complications. Surgeons may take this into consideration when deciding closure techniques for ankle fractures. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  10. Baseline data from a multicenter, 5-year, prospective cohort study of Japanese age-related macular degeneration: an AMD2000 report.

    Science.gov (United States)

    Tsujikawa, Akitaka; Akagi-Kurashige, Yumiko; Yuzawa, Mitsuko; Ishibashi, Tatsuro; Nakanishi, Hideo; Nakatani, Eiji; Teramukai, Satoshi; Fukushima, Masanori; Yoshimura, Nagahisa

    2018-03-01

    To report research participants' baseline characteristics in the AMD2000 study, a prospective, multicenter, 5-year, observational cohort study of Japanese age-related macular degeneration (AMD). The characteristics were determined using multimodal imaging. Patients with AMD were recruited at 18 clinical sites in Japan between April 2006 and March 2009. Each patient underwent a complete ophthalmic examination, including measurement of best-corrected visual acuity (Landolt chart), indirect ophthalmoscopy, slit-lamp biomicroscopy with a contact lens, optical coherence tomography imaging, fundus photography, and fluorescein and indocyanine green angiography. Four hundred sixty participants (326 men [70.9%]) were included in the study. At enrollment, 131 eyes (28.5%) had hard drusen and 125 eyes (27.2%) had soft drusen in the macular area. A total of 455 eyes (98.9%) were diagnosed as having wet AMD, and 5 eyes (1.1%), as having dry AMD. Of the 455 eyes with wet AMD, 209 eyes (45.4%) had typical AMD, 228 eyes (49.6%) had polypoidal choroidal vasculopathy (PCV), and 18 eyes (3.9%) had retinal angiomatous proliferation. The size of choroidal neovascularization (CNV) was significantly smaller with indocyanine green angiography than with fluorescein angiography (P macular edema, older age, scar, extrafoveal macular edema, subfoveal CNV, large branching vascular network, and hard exudates. Japanese patients with AMD are predominantly male, lack drusen, and have a high rate of PCV.

  11. Corantes vitais em cromovitrectomia Vital dyes in chromovitrectomy

    Directory of Open Access Journals (Sweden)

    Eduardo Dib

    2009-12-01

    Full Text Available O objetivo do artigo é apresentar os dados atuais da aplicação de corantes vitais durante cirurgia vitreorretiniana, "cromovitrectomia", bem como uma revisão da literatura atual sobre o assunto no tocante às técnicas de aplicação, indicações e complicações em cromovitrectomia. Um grande número de publicações tem abordado o perfil tóxico da indocianina verde na cromovitrectomia. Dados experimentais mostram uma toxicidade dose-dependente da mesma em várias populações de células retinianas. Novas gerações de corantes incluem: azul tripan, azul patente, acetato de triancinolona, infracianina verde, fluoresceína sódica, azul de bromofenol, acetato de fluorometolona e azul brilhante. Novos instrumentos podem permitir um corar seletivo de estruturas durante a vitrectomia. Este artigo mostra que o campo da cromovitrectomia está em plena expansão de pesquisas. Os corantes de primeira linha são a indocianina verde, infracianina verde e o azul brilhante. Azul patente, azul de bromofenol e azul tripan surgem como novos adjuvantes para melhor observação da membrana epirretiniana. Demais corantes que surgiram merecem maior investigação.The aim of this article is to present the current data with regard to the application of vital dyes during vitreoretinal surgery, "chromovitrectomy", as well as to overview the current literature regarding the properties of dyes, techniques of application, indications and complications in chromovitrectomy. A large body of published research has recently addressed the toxicity profile of indocyanine green for chromovitrectomy. Experimental data demonstrate dose-dependent toxicity of indocyanine green to various retinal cells. Newer generation vital dyes for chromovitrectomy include trypan blue, patent blue, triamcinolone acetonide, infracyanine green, sodium fluorescein, bromophenol blue, fluorometholone acetate and brilliant blue. Novel instruments may enable a selective painting of preretinal

  12. Near-infrared intraoperative imaging during resection of an anterior mediastinal soft tissue sarcoma.

    Science.gov (United States)

    Predina, Jarrod D; Newton, Andrew D; Desphande, Charuhas; Singhal, Sunil

    2018-01-01

    Sarcomas are rare malignancies that are generally treated with multimodal therapy protocols incorporating complete local resection, chemotherapy and radiation. Unfortunately, even with this aggressive approach, local recurrences are common. Near-infrared intraoperative imaging is a novel technology that provides real-time visual feedback that can improve identification of disease during resection. The presented study describes utilization of a near-infrared agent (indocyanine green) during resection of an anterior mediastinal sarcoma. Real-time fluorescent feedback provided visual information that helped the surgeon during tumor localization, margin assessment and dissection from mediastinal structures. This rapidly evolving technology may prove useful in patients with primary sarcomas arising from other locations or with other mediastinal neoplasms.

  13. Laser welding of vas deferens in rodents: initial experience with fluid solders.

    Science.gov (United States)

    Trickett, R I; Wang, D; Maitz, P; Lanzetta, M; Owen, E R

    1998-01-01

    This study evaluates the use of sutureless laser welding for vasovasostomy. In 14 rodents, the left vas deferens underwent vasovasostomy using an albumin-based solder applied to the adventitia of the vas deferens. The solder contained the dye, indocyanine green, to allow selective absorption and denaturation by a fiber-coupled 800-nm diode laser. The right vas deferens served as a control, receiving conventional layered microsurgical repair. We used a removable 4/0 nylon stent and microclamps to appose the vas deferens during repair, with no need for stay sutures. The mean time to perform laser solder repair (23.5 min) and conventional repair (23.3 min) were not significantly different (P=0.91). However, examination after 8 weeks showed that granuloma formation (G) and patency (P) rates for the conventional suture technique (G, 14%; P, 93%) were significantly better than observed for the laser solder technique (G, 57%; P, 50%).

  14. Atomic force microscopy and transmission electron microscopy analyses of low-temperature laser welding of the cornea.

    Science.gov (United States)

    Matteini, Paolo; Sbrana, Francesca; Tiribilli, Bruno; Pini, Roberto

    2009-07-01

    Low-temperature laser welding of the cornea is a technique used to facilitate the closure of corneal cuts. The procedure consists of staining the wound with a chromophore (indocyanine green), followed by continuous wave irradiation with an 810 nm diode laser operated at low power densities (12-16 W/cm(2)), which induces local heating in the 55-65 degrees C range. In this study, we aimed to investigate the ultrastructural modifications in the extracellular matrix following laser welding of corneal wounds by means of atomic force microscopy and transmission electron microscopy. The results evidenced marked disorganization of the normal fibrillar assembly, although collagen appeared not to be denatured under the operating conditions we employed. The mechanism of low-temperature laser welding may be related to some structural modifications of the nonfibrillar extracellular components of the corneal stroma.

  15. Laser tissue welding in ophthalmic surgery.

    Science.gov (United States)

    Rossi, Francesca; Matteini, Paolo; Ratto, Fulvio; Menabuoni, Luca; Lenzetti, Ivo; Pini, Roberto

    2008-09-01

    Laser welding of ocular tissues is an alternative technique or adjunct to conventional suturing in ophthalmic surgery. It is based on the photothermal interaction of laser light with the main components of the extracellular matrix of connective tissues. The advantages of the welding procedure with respect to standard suturing and stapling are reduced operation times, lesser inflammation, faster healing and increased ability to induce tissue regeneration. The procedure we set up is based on the use of an infrared diode laser in association with the topical application of the chromophore Indocyanine Green. Laser light may be delivered either continuously or in pulses, thus identifying two different techniques that have been applied clinically in various types of transplants of the cornea.

  16. Laser-activated solid protein bands for peripheral nerve repair: an vivo study.

    Science.gov (United States)

    Lauto, A; Trickett, R; Malik, R; Dawes, J M; Owen, E R

    1997-01-01

    Severed tibial nerves in rats were repaired using a novel technique, utilizing a semiconductor diode-laser-activated protein solder applied longitudinally across the join. Welding was produced by selective laser denaturation of solid solder bands containing the dye indocyanine green. An in vivo study, using 48 adult male Wistar rats, compared conventional microsuture-repaired tibial nerves with laser solder-repaired nerves. Nerve repairs were characterised immediately after surgery and after 3 months. Successful regeneration with average compound muscle action potentials of 2.5 +/- 0.5 mV and 2.7 +/- 0.3 mV (mean and standard deviation) was demonstrated for the laser-soldered nerves and the sutured nerves, respectively. Histopathology confirmed comparable regeneration of axons in laser- and suture-operated nerves. The laser-based nerve repair technique was easier and faster than microsuture repair, minimising manipulation damage to the nerve.

  17. Tracheal anastomosis with the diode laser and fibrin tissue adhesive: an in vitro and in vivo investigation.

    Science.gov (United States)

    Gleich, L L; Wang, Z; Pankratov, M M; Aretz, H T; Shapshay, S M

    1995-05-01

    Absorbable sutures have been advocated for tracheal anastomosis to reduce fibrosis and foreign body reaction leading to recurrent stenosis. Fibrin tissue adhesive (FTA) and diode laser welding with indocyanine green-dyed fibrinogen were evaluated in tracheal anastomosis to reduce the number of sutures and to improve healing. In vitro studies demonstrated strong anastomoses with a combination of laser welding and FTA with minimal tissue damage. In a controlled in vivo study, circumferential resections of canine tracheas were repaired with laser welding and FTA augmented with a few stay sutures. These anastomoses had less fibrosis and tissue damage than anastomoses in control animals repaired with sutures alone. This study supports investigation of laser welding and FTA in human beings for tracheal anastomosis and other procedures in which suturing may be difficult.

  18. Alternative wavelengths for sutureless laser microvascular anastomosis: a preliminary study on acute samples.

    Science.gov (United States)

    Bass, L S; Oz, M C; Libutti, S K; Treat, M R

    1992-06-01

    Attempts to improve the speed and patency of microvascular anastomosis with laser-assisted techniques have provided a modest reduction in operative time and comparable success rates. Using sutureless microvascular anastomoses, 30 end-to-end anastomoses were created in the rat carotid artery using the gallium-aluminum-arsenide diode laser (808 nm). Indocyanine green and fibrinogen were applied to enhance tissue absorption of the laser energy and strengthen the bond created. These were compared with previously reported welds using the THC:YAG laser (2150 nm). Mean welding times were 140 and 288 s, and mean bursting pressures immediately after welding were 515 and 400 mmHg for the diode and THC:YAG laser groups, respectively. Histologically, both lateral and vertical spread of thermal damage was limited. Since both lasers create welds of adequate initial strength without stay sutures and are faster and easier to use than existing systems, evaluation of long-term patency would be worthwhile.

  19. Laser tissue welding mediated with a protein solder

    Science.gov (United States)

    Small, Ward, IV; Heredia, Nicholas J.; Celliers, Peter M.; Da Silva, Luiz B.; Eder, David C.; Glinsky, Michael E.; London, Richard A.; Maitland, Duncan J.; Matthews, Dennis L.; Soltz, Barbara A.

    1996-05-01

    A study of laser tissue welding mediated with an indocyanine green dye-enhanced protein solder was performed. Freshly obtained sections of porcine artery were used for the experiments. Sample arterial wall thickness ranged from two to three millimeters. Incisions approximately four millimeters in length were treated using an 805 nanometer continuous- wave diode laser coupled to a one millimeter diameter fiber. Controlled parameters included the power delivered by the laser, the duration of the welding process, and the concentration of dye in the solder. A two-color infrared detection system was constructed to monitor the surface temperatures achieved at the weld site. Burst pressure measurements were made to quantify the strengths of the welds immediately following completion of the welding procedure.

  20. Prevention of pharyngocutaneous fistulas by means of laser-weld techniques.

    Science.gov (United States)

    Shohet, J A; Reinisch, L; Ossoff, R H

    1995-07-01

    Although much has been written on methods of dealing with pharyngocutaneous fistulas once they have formed, there are few reports of methods of preventing fistula formation from occurring. We examined the use of laser-weld techniques with the neodymium:yttrium aluminum garnet (Nd:YAG) and diode lasers to seal pharyngotomy closures. Laser-weld techniques have been used successfully in many other tissues, but reports documenting use in the upper aerodigestive tract are minimal. Indocyanine-green dye-enhanced collagen and fibrinogen were studied as laser solder materials for the diode laser. Twenty-nine experimental animals were studied. Neither the Nd:YAG nor the diode laser was successful in preventing fistula formation. Tensiometric studies documented significant strength of the laser welds ex vivo, but this finding was not clinically significant.

  1. Endoscopic diode laser welding of mucosal grafts on the larynx: a new technique.

    Science.gov (United States)

    Wang, Z; Pankratov, M M; Rebeiz, E E; Perrault, D F; Shapshay, S M

    1995-01-01

    Epithelial coverage of a laryngotracheal wound is an important factor in preventing stenosis, and endoscopic transplantation of a free mucosal graft without stents or sutures would be a significant therapeutic advance. In vitro and in vivo canine studies were performed to explore the feasibility of transplantation with a low-power diode laser (400 mW) enhanced by indocyanine green dye-doped albumin. The tensile strength of graft adherence in 10 cadaver larynges was strong (35.25 +/- 10.39 g). Survival studies in live canine models with a specially designed endoscopic instrument set showed excellent healing at 6, 14, and 28 days. Healing was documented with photography and by histologic examination. Successful endoscopic transplantation of a free mucosal graft should improve results of treatment for laryngotracheal stenosis and laryngeal reconstructive surgery.

  2. Benchtop and animal validation of a portable fluorescence microscopic imaging system for potential use in cholecystectomy

    Science.gov (United States)

    Ye, Jian; Liu, Guanghui; Liu, Peng; Zhang, Shiwu; Shao, Pengfei; Smith, Zachary J.; Liu, Chenhai; Xu, Ronald X.

    2018-02-01

    We propose a portable fluorescence microscopic imaging system (PFMS) for intraoperative display of biliary structure and prevention of iatrogenic injuries during cholecystectomy. The system consists of a light source module, a camera module, and a Raspberry Pi computer with an LCD. Indocyanine green (ICG) is used as a fluorescent contrast agent for experimental validation of the system. Fluorescence intensities of the ICG aqueous solution at different concentration levels are acquired by our PFMS and compared with those of a commercial Xenogen IVIS system. We study the fluorescence detection depth by superposing different thicknesses of chicken breast on an ICG-loaded agar phantom. We verify the technical feasibility for identifying potential iatrogenic injury in cholecystectomy using a rat model in vivo. The proposed PFMS system is portable, inexpensive, and suitable for deployment in resource-limited settings.

  3. Value of internal limiting membrane peeling in surgery for idiopathic macular hole stage 2 and 3: a randomised clinical trial

    DEFF Research Database (Denmark)

    Christensen, U C; Krøyer, K; Sander, B

    2009-01-01

    AIM: To determine the effect of internal limiting membrane (ILM) peeling on anatomical and functional success rates in stage 2 and 3 idiopathic macular hole surgery (MHS). METHODS: Randomised clinical trial of stage 2 and 3 idiopathic macular hole without visible epiretinal fibrosis and with less...... than 1 year's duration of symptoms. Eyes were randomised to (1) vitrectomy alone without retinal surface manipulation, (2) vitrectomy plus 0.05% isotonic Indocyanine Green (ICG)-assisted ILM peeling or (3) vitrectomy plus 0.15% Trypan Blue (TB)-assisted ILM peeling. Main outcomes were hole closure...... after 3 and 12 months and best-corrected visual acuity after 12 months. RESULTS: 78 eyes were enrolled. Primary closure rates were significantly higher with ILM peeling than without peeling for both stage 2 holes (ICG peeling 100%, non-peeling 55%, p = 0.014) and for stage 3 holes (ICG peeling 91%, TB...

  4. Macular morphology and visual acuity after macular hole surgery with or without internal limiting membrane peeling

    DEFF Research Database (Denmark)

    Christensen, U.C.; Kroyer, K.; Sander, B.

    2010-01-01

    Aim: To examine postoperative macular morphology and visual outcome after 12 months in relation to internal limiting membrane (ILM) peeling versus no peeling, indocyanine green (ICG) staining and re-operation in eyes that achieved macular hole closure after surgery. Methods: Seventy-four eyes...... with closed stage 2 or 3 macular holes were recruited from a randomised clinical trial comparing: (1) vitrectomy without ILM peeling; (2) vitrectomy with 0.05% isotonic ICG-assisted ILM peeling; and (3) vitrectomy with 0.15% trypan blue-assisted ILM peeling. Contrast-enhanced Stratus optical coherence...... between subgroups. Conclusions: Poor vision after 12 months despite macular hole closure was associated with attenuation and disruption of the foveolar photoreceptor matrix. The extent of attenuation and disruption was independent of peeling and staining....

  5. Effect of capsid proteins to ICG mass ratio on fluorescent quantum yield of virus-resembling optical nano-materials

    Science.gov (United States)

    Gupta, Sharad; Ico, Gerardo; Matsumura, Paul; Rao, A. L. N.; Vullev, Valentine; Anvari, Bahman

    2012-03-01

    We recently reported construction of a new type of optical nano-construct composed of genome-depleted plant infecting brome mosaic virus (BMV) doped with Indocyanine green (ICG), an FDA-approved chromophore. We refer to these constructs as optical viral ghosts (OVGs) since only the capsid protein (CP) subunits of BMV remain to encapsulate ICG. To utilize OVGs as effective nano-probes in fluorescence imaging applications, their fluorescence quantum yield needs to be maximized. In this study, we investigate the effect of altering the CP to ICG mass ratio on the fluorescent quantum yield of OVGs. Results of this study provide the basis for construction of OVGs with optimal amounts of CP and ICG to yield maximal fluorescence quantum yield.

  6. Quantification of fluorescence angiography in a porcine model

    DEFF Research Database (Denmark)

    Nerup, Nikolaj; Andersen, Helene Schou; Ambrus, Rikard

    2017-01-01

    PURPOSE: There is no consensus on how to quantify indocyanine green (ICG) fluorescence angiography. The aim of the present study was to establish and gather validity evidence for a method of quantifying fluorescence angiography, to assess organ perfusion. METHODS: Laparotomy was performed on seven...... pigs, with two regions of interest (ROIs) marked. ICG and neutron-activated microspheres were administered and the stomach was illuminated in the near-infrared range, parallel to continuous recording of fluorescence signal. Tissue samples from the ROIs were sent for quantification of microspheres...... to calculate the regional blood flow. A software system was developed to assess the fluorescent recordings quantitatively, and each quantitative parameter was compared with the regional blood flow. The parameter with the strongest correlation was then compared with results from an independently developed...

  7. [Intraoperative detection of the sentinel lymph nodes in lung cancer].

    Science.gov (United States)

    Akopov, A L; Papayan, G V; Chistyakov, I V

    2015-01-01

    An analysis of the scientific data was made. It was used the literature devoted to the intraoperative visualization of the sentinel lymph nodes in patients with lung cancer. Correct detection of such lymph nodes with following pathologic investigation allowed limiting the volume of lympho-dissection in a number of patients. There is the possibility of maximal in-depth study of the sentinel lymph nodes by purposeful application of most sensible pathologic and molecular methods for detection their micrometastatic lesions. At the same time the treatment strategy and prognosis could be determined. The authors present the results of an application of dye techniques, radioactive preparation and fluorescence imaging for sentinel lymph node detection. Advantages and disadvantages of the methods are shown in the article. There are validated the prospects of technical development, study of information value of new applications and the most perspective method of fluorescence indocyanine green visualization by lymph outflow.

  8. Errors of the backextrapolation method in determination of the blood volume

    Science.gov (United States)

    Schröder, T.; Rösler, U.; Frerichs, I.; Hahn, G.; Ennker, J.; Hellige, G.

    1999-01-01

    Backextrapolation is an empirical method to calculate the central volume of distribution (for example the blood volume). It is based on the compartment model, which says that after an injection the substance is distributed instantaneously in the central volume with no time delay. The occurrence of recirculation is not taken into account. The change of concentration with time of indocyanine green (ICG) was observed in an in vitro model, in which the volume was recirculating in 60 s and the clearance of the ICG could be varied. It was found that the higher the elimination of ICG, the higher was the error of the backextrapolation method. The theoretical consideration of Schröder et al ( Biomed. Tech. 42 (1997) 7-11) was proved. If the injected substance is eliminated somewhere in the body (i.e. not by radioactive decay), the backextrapolation method produces large errors.

  9. Nitric oxide and prostaglandins influence local skeletal muscle blood flow during exercise in humans: coupling between local substrate uptake and blood flow

    DEFF Research Database (Denmark)

    Kalliokoski, Kari K; Langberg, Henning; Ryberg, Ann Kathrine

    2006-01-01

    -legged dynamic knee-extension exercise. Local blockade was produced by infusing nitro-L-arginine methyl ester and indomethacin directly in the muscle via a microdialysis catheter. Blood flow and glucose uptake were measured in the region of blockade and in two additional regions of vastus lateralis muscle 1......Synergic action of nitric oxide (NO) and prostaglandins (PG) in the regulation of muscle blood flow during exercise has been demonstrated. In the present study, we investigated whether these vasodilators also regulate local blood flow, flow heterogeneity, and glucose uptake within the exercising...... skeletal muscle. Skeletal muscle blood flow was measured in seven healthy young men using near-infrared spectroscopy and indocyanine green and muscle glucose uptake using positron emission tomography and 2-fluoro-2-deoxy-D-[(18)F]glucose without and with local blockade of NO and PG at rest and during one...

  10. Preliminary results with sutured colonic anastomoses reinforced with dye-enhanced fibrinogen and a diode laser

    Science.gov (United States)

    Libutti, Steven K.; Williams, Matthew R.; Oz, Mehmet C.; Forde, Kenneth A.; Bass, Lawrence S.; Weinstein, Samuel; Auteri, Joseph S.; Treat, Michael R.; Nowygrod, Roman

    1991-07-01

    A common cause of morbidity in patients recovering from bowel surgery is leakage from colonic anastomoses. A technique utilizing a laser activated protein solder to strengthen colonic anastomoses in a canine model was evaluated. Following creation of six single-layer interrupted suture anastomoses in four dogs, a protein solder consisting of indocyanine green dye and fibrinogen was topically appied to the serosal surface and exposed to 808 nm continuous wave diode laser energy. Immediately following anastomosis, the mean leakage pressure of sutures alone was 129 +/- 14 mm hg (n equals 6), while the mean leakage pressure of sutures reinforced with the laser welded solder was 312 +/- 32 mm hg (n equals 6) (p anastomoses without causing appreciable thermal injury to surrounding tissues.

  11. Effect of isolated hepatic ischemia on organic anion clearance and oxidative metabolism.

    Science.gov (United States)

    Minard, G; Bynoe, R; Wood, G C; Fabian, T C; Croce, M; Kudsk, K A

    1992-04-01

    Hepatic failure is frequently seen following severe hemorrhagic shock, sepsis, and trauma. Clearance of various drugs has been used to evaluate hepatocellular dysfunction, including indocyanine green (ICG), an organic anionic dye that is transported similarly to bilirubin, and antipyrine (AP), a marker of oxidative phosphorylation. Previous investigators have noted a decrease in ICG excretion following systemic hemorrhage. The effect of isolated hepatic ischemia on the clearances of ICG and AP was studied in 16 pigs after 90 minutes of vascular occlusion to the liver. Antipyrine clearance decreased almost 50% from baseline values at 24 and 72 hours after the ischemia procedure, indicating a significant depression in the cytochrome P-450 system. On the other hand, ICG clearance did not change significantly. In conclusion, ICG clearance is not depressed after isolated hepatic ischemia in pigs. Changes in organic anion clearance after systemic hemorrhage may be because of release of toxic products from ischemic peripheral tissue.

  12. Functional Near-Infrared Fluorescence Imaging for Cardiac Surgery and Targeted Gene Therapy

    Directory of Open Access Journals (Sweden)

    Akira Nakayama

    2002-10-01

    Full Text Available Cardiac revascularization is presently performed without realtime visual assessment of myocardial blood flow or perfusion. Moreover, gene therapy of the heart cannot, at present, be directed to specific territories at risk for myocardial infarction. We have developed a surgical imaging system that exploits the low autofluorescence, deep tissue penetration, low tissue scatter, and invisibility of near-infrared (NIR fluorescent light. By completely isolating visible and NIR light paths, one is able to visualize, simultaneously, the anatomy and/or function of the heart, or any desired tissue. In rat model systems, we demonstrate that the heptamethine indocyanine-type NIR fluorophores IR-786 and the carboxylic acid form of IRDye78 can be injected intravenously in the living animal to provide real-time visual assessment of myocardial blood flow or perfusion intraoperatively. This imaging system may prove useful for the refinement of revascularization techniques, and for the administration of cardiac gene therapy.

  13. Thermoacoustic Molecular Imaging of Small Animals

    Directory of Open Access Journals (Sweden)

    Robert A. Kruger

    2003-04-01

    Full Text Available We have designed, constructed, and tested a thermoacoustic computed tomography (TCT scanner for imaging optical absorption in small animals in three dimensions. The device utilizes pulsed laser irradiation (680–1064 nm and a unique, 128-element transducer array. We quantified the isotropic spatial resolution of this scanner to be 0.35 mm. We describe a dual-wavelength subtraction technique for isolating optical dyes with TCT. Phantom experiments demonstrate that we can detect 5 fmol of a near-infrared dye (indocyanine green, ICG in a 1-ML volume using dual-wavelength subtraction. Initial TCT imaging in phantoms and in two sacrificed mice suggests that three-dimensional, optical absorption patterns in small animals can be detected with an order of magnitude better spatial resolution and an order of magnitude better low-contrast detectability in small animals when compared to fluorescence imaging or diffusion optical tomography.

  14. Near infrared spatial frequency domain fluorescence imaging of tumor phantoms containing erythrocyte-derived optical nanoplatforms

    Science.gov (United States)

    Burns, Joshua M.; Schaefer, Elise; Anvari, Bahman

    2018-02-01

    Light-activated theranostic constructs provide a multi-functional platform for optical imaging and phototherapeutic applications. Our group has engineered nano-sized vesicles derived from erythrocytes that encapsulate the FDAapproved near infrared (NIR) absorber indocyanine green (ICG). We refer to these constructs as NIR erythrocytemimicking transducers (NETs). Once photo-excited by NIR light these constructs can transduce the photons energy to emit fluorescence, generate heat, or induce chemical reactions. In this study, we investigated fluorescence imaging of NETs embedded within tumor phantoms using spatial frequency domain imaging (SFDI). Using SFDI, we were able to fluorescently image simulated tumors doped with different concentration of NETs. These preliminary results suggest that NETs can be used in conjunction with SFDI for potential tumor imaging applications.

  15. Fundus Autofluorescence in Multiple Evanescent White Dot Syndrome

    Directory of Open Access Journals (Sweden)

    Fernando Marcondes Penha

    2011-01-01

    Full Text Available A patient complained of photopsia and vision loss in the left eye for two days, with visual acuity of 20/32. Right eye was normal. Funduscopy revealed foveal granularity and gray-white lesions in the posterior pole, mainly temporal to the fovea. The lesions (dots and spots, along with a few other areas surrounding them, showed hyperautofluorescence on autofluorescence imaging. Fluorescein angiogram (FA depicted some early hyperfluorescent dots with late staining. Indocyanine green angiogram (ICGA showed hypofluorescent lesions in a greater number compared with funduscopy, autofluorescence, and FA. Thirty days later, BCVA was 20/20 in both eyes and the complimentary exams were almost normal, despite an ICGA that showed few small hypofluorescent lesions. This case supports the hypothesis that the choroidal involvement occurs primarily in MEWDS, with secondary involvement of the RPE and the neurosensory retina.

  16. Adaptive optics scanning laser ophthalmoscopy in fundus imaging, a review and update

    Directory of Open Access Journals (Sweden)

    Bing Zhang

    2017-11-01

    Full Text Available Adaptive optics scanning laser ophthalmoscopy (AO-SLO has been a promising technique in funds imaging with growing popularity. This review firstly gives a brief history of adaptive optics (AO and AO-SLO. Then it compares AO-SLO with conventional imaging methods (fundus fluorescein angiography, fundus autofluorescence, indocyanine green angiography and optical coherence tomography and other AO techniques (adaptive optics flood-illumination ophthalmoscopy and adaptive optics optical coherence tomography. Furthermore, an update of current research situation in AO-SLO is made based on different fundus structures as photoreceptors (cones and rods, fundus vessels, retinal pigment epithelium layer, retinal nerve fiber layer, ganglion cell layer and lamina cribrosa. Finally, this review indicates possible research directions of AO-SLO in future.

  17. Update on wide- and ultra-widefield retinal imaging

    Directory of Open Access Journals (Sweden)

    Samir S Shoughy

    2015-01-01

    Full Text Available The peripheral retina is the site of pathology in many ocular diseases and ultra-widefield (UWF imaging is one of the new technologies available to ophthalmologists to manage some of these diseases. Currently, there are several imaging systems used in practice for the purpose of diagnostic, monitoring disease progression or response to therapy, and telemedicine. These include modalities for both adults and pediatric patients. The current systems are capable of producing wide- and UWF color fundus photographs, fluorescein and indocyanine green angiograms, and autofluorescence images. Using this technology, important clinical observations have been made in diseases such as diabetic retinopathy, uveitides, retinal vascular occlusions and tumors, intraocular tumors, retinopathy of prematurity, and age-related macular degeneration. Widefield imaging offers excellent postoperative documentation of retinal detachment surgery. New applications will soon be available to integrate this technology into large volume routine clinical practice.

  18. Surgical treatment of cerebral ischemia by means of diode laser: first experimental results and comparison with theoretical model

    Science.gov (United States)

    Signorelli, C. D.; Giaquinta, A.; Iofrida, G.; Donato, G.; Signorelli, Fr.; Bellecci, C.; Lo Feudo, T.; Gaudio, P.; Gelfusa, M.

    2007-07-01

    In the present paper feasibility and potential advantages of using diode laser for surgical treatment of cerebral ischemia and intracranial aneurysms will be evaluated. At this purpose non linear mathematical model was developed and experimentally validated to investigate the effects of the changes in tissue physical properties, in terms of operating time, tensile strength and tissue damage during medical laser application. The numerical simulations have been carried on by a finite-elements based software package (FEMLAB). In vitro results of human saphenous veins of inferior limbs (n=55) after 799 nm diode laser soldering, combined with an indocyanine green-enhanced, will be presented. The simulations results and their comparison with experimental measurements will be reported.

  19. Quantitative self-assembly prediction yields targeted nanomedicines

    Science.gov (United States)

    Shamay, Yosi; Shah, Janki; Işık, Mehtap; Mizrachi, Aviram; Leibold, Josef; Tschaharganeh, Darjus F.; Roxbury, Daniel; Budhathoki-Uprety, Januka; Nawaly, Karla; Sugarman, James L.; Baut, Emily; Neiman, Michelle R.; Dacek, Megan; Ganesh, Kripa S.; Johnson, Darren C.; Sridharan, Ramya; Chu, Karen L.; Rajasekhar, Vinagolu K.; Lowe, Scott W.; Chodera, John D.; Heller, Daniel A.

    2018-02-01

    Development of targeted nanoparticle drug carriers often requires complex synthetic schemes involving both supramolecular self-assembly and chemical modification. These processes are generally difficult to predict, execute, and control. We describe herein a targeted drug delivery system that is accurately and quantitatively predicted to self-assemble into nanoparticles based on the molecular structures of precursor molecules, which are the drugs themselves. The drugs assemble with the aid of sulfated indocyanines into particles with ultrahigh drug loadings of up to 90%. We devised quantitative structure-nanoparticle assembly prediction (QSNAP) models to identify and validate electrotopological molecular descriptors as highly predictive indicators of nano-assembly and nanoparticle size. The resulting nanoparticles selectively targeted kinase inhibitors to caveolin-1-expressing human colon cancer and autochthonous liver cancer models to yield striking therapeutic effects while avoiding pERK inhibition in healthy skin. This finding enables the computational design of nanomedicines based on quantitative models for drug payload selection.

  20. Using fluorescence lymphangiography to define the ileocolic mesentery: proof of concept for the watershed area using real-time imaging.

    Science.gov (United States)

    Keller, D S; Joshi, H M; Rodriguez-Justo, M; Walsh, D; Coffey, J C; Chand, M

    2017-09-01

    Recent advances in mesenteric science have demonstrated that the mesentery is a continuous structure with a 'watershed' area at the mesenteric apex between the right colon and terminal ileum, where lymphatic flow can proceed either proximally or distally. With this new understanding of the anatomy, functional features are emerging, which can have an impact on surgical management. Fluorescence lymphangiography or lymphoscintigraphy with indocyanine green allows real-time visualization of lymphatic channels, which highlights sentinel lymph nodes and may facilitate identification of the ideal margins for mesenteric lymphadenectomy during bowel resection for colon cancer. By using this novel technology, it is possible to demonstrate a watershed area in the ileocolic region and may facilitate more precise mesenteric dissection. In the present study, we provide proof of concept for the ileocolic watershed area using fluorescence lymphangiography.

  1. Glucose production during exercise in humans

    DEFF Research Database (Denmark)

    Bergeron, R; Kjaer, M; Simonsen, L

    1999-01-01

    at 50.4 +/- 1.5(SE)% maximal O(2) consumption, followed by 30 min at 69.0 +/- 2.2% maximal O(2) consumption. The splanchnic blood flow was estimated by continuous infusion of indocyanine green, and net splanchnic glucose output was calculated as the product of splanchnic blood flow and a-hv blood...... glucose concentration differences. Glucose appearance rate was determined by a primed, continuous infusion of [3-(3)H]glucose and was calculated by using formulas for a modified single compartment in non-steady state. Glucose production was similar whether determined by the a-hv balance technique......The present study compared the arteriohepatic venous (a-hv) balance technique and the tracer-dilution method for estimation of hepatic glucose production during both moderate and heavy exercise in humans. Eight healthy young men (aged 25 yr; range, 23-30 yr) performed semisupine cycling for 40 min...

  2. Peptide-Based Optical uPAR Imaging for Surgery

    DEFF Research Database (Denmark)

    Juhl, Karina; Christensen, Anders; Persson, Morten

    2016-01-01

    Near infrared intra-operative optical imaging is an emerging technique with clear implications for improved cancer surgery by enabling a more distinct delineation of the tumor margins during resection. This modality has the potential to increase the number of patients having a curative radical...... tumor resection. In the present study, a new uPAR-targeted fluorescent probe was developed and the in vivo applicability was evaluated in a human xenograft mouse model. Most human carcinomas express high level of uPAR in the tumor-stromal interface of invasive lesions and uPAR is therefore considered...... an ideal target for intra-operative imaging. Conjugation of the flourophor indocyanine green (ICG) to the uPAR agonist (AE105) provides an optical imaging ligand with sufficiently high receptor affinity to allow for a specific receptor targeting in vivo. For in vivo testing, human glioblastoma xenograft...

  3. Lateral gaze palsy as the initial clinical sign in a case of brainstem glioma

    International Nuclear Information System (INIS)

    Nakamura, Reiko; Saitou, Tamiya; Deguchi, Tatsuya; Yoneya, Shin

    1997-01-01

    Three patients were diagnosed as radiation retinopathy with characteristic funduscopic features. Fluorescein angiography showed areas of retinal capillary nonperfusion corresponding to cotton-wool spots. Indocyanine green (ICG) angiography in two elder patients showed patchy hyperfluorescent spots and disseminated hypofluorescent areas suggesting occlusion of choroidal vessels. The choroidal vascular lesions involved wider areas than retinal vascular occlusions. In the third patient aged 20, ICG angiography showed retarded dye inflow and moderate hypofluorescence in the choroid in spite of drastic retinal vascular lesions. The findings suggest that choroidal vascular lesions may be present in radiation retinopathy and that the severity and distribution of choroidal lesions do not necessarily correspond to those in the retina. (author)

  4. Transient spectral domain optical coherence tomography findings in classic MEWDS: a case report.

    Science.gov (United States)

    Lavigne, Luciana Castro; Isaac, David Leonardo Cruvinel; Duarte Júnior, José Osório; Avila, Marcos Pereira de

    2014-01-01

    The purpose of this study was to describe a patient with multiple evanescent white dot syndrome (MEWDS) who presented with classic retinal findings and transient changes in outer retinal anatomy. A 20-year-old man presented with mild blurred vision in the left eye, reporting flu-like symptoms 1 week before the visual symptoms started. Fundus examination of the left eye revealed foveal granularity and multiple scattered spots deep to the retina in the posterior pole. Fluorescein angiography and indocyanine green angiography showed typical MEWDS findings. Spectral Domain Optical Coherence Tomography has shown transient changes in outer retinal anatomy with disappearance of inner segment-outer segment junction and mild attenuation of external limiting membrane. Six months later, Spectral Domain Optical Coherence Tomography has shown complete resolution with recovery of normal outer retinal aspect.

  5. [A Case of Gastric Cancer with Splenic Artery Aneurysm, Intraoperative ICG Fluorography Is Useful in Evaluating the Blood Flow of Stomach and Spleen].

    Science.gov (United States)

    Usui, Kenji; Sakamoto, Kaoru; Akabane, Kentaro; Hayasaka, Kazuki; Mizuki, Toru; Yagi, Yutaka; Shirahata, Yasuhiro; Ichikawa, Hiroshi; Hanyu, Takaaki; Ishikawa, Takashi; Kameyama, Hitoshi; Suzuki, Satoshi; Saito, Kiyohiro; Wakai, Toshifumi

    2017-11-01

    An 81-year-oldwoman with advancedgastric cancer was referredto our hospital. Preoperative contrast-enhancedCT revealeda roundcalcification of the splenic hilum with 15mm in diameter as a splenic artery aneurysm. She underwent transcatheter arterial embolization(TAE)for the splenic artery aneurysm. Celiac artery angiography showedcollateral arterial network of the spleen from left gastric artery. Surgery for the gastric cancer was performed1 4 days after TAE. We cut the right gastric andbilateral epigastric arteries. After the left gastric artery clamping, we performedintraoperative indocyanine green(ICG)fluorography. ICG fluorography confirmedthat the bloodflow of the upper thirdof the stomach andspleen were maintained. We safely performed distal gastrectomy, and the postoperative course was uneventful.

  6. Histological study of subcutaneous fat at NIR laser treatment of the rat skin in vivo

    Science.gov (United States)

    Yanina, I. Y.; Svenskaya, Yu. I.; Navolokin, N. A.; Matveeva, O. V.; Bucharskaya, A. B.; Maslyakova, G. N.; Gorin, D. A.; Sukhorukov, G. B.; Tuchin, V. V.

    2015-07-01

    The goal of this work is to quantify impact of in vivo photochemical treatment using indocyanine green (ICG) or encapsulated ICG and NIR laser irradiation through skin of rat with obesity by the follow up tissue sampling and histochemistry. After 1 hour elapsed since 1-min light exposure samples of rat skin with subcutaneous tissue of thickness of 1.5-2.5 mm were taken by surgery from rats within marked 4-zones of the skin site. For hematoxylin-eosin histological examination of excised tissue samples, fixation was carried out by 10%-formaldehyde solution. For ICG and encapsulated ICG subcutaneous injection and subsequent 1-min diode laser irradiation with power density of 8 W/cm2, different necrotic regions with lipolysis of subcutaneous fat were observed. The obtained data can be used for safe layer-by-layer laser treatment of obesity and cellulite.

  7. Three-dimensional in vivo fluorescence diffuse optical tomography of breast cancer in humans

    Science.gov (United States)

    Corlu, Alper; Choe, Regine; Durduran, Turgut; Rosen, Mark A.; Schweiger, Martin; Arridge, Simon R.; Schnall, Mitchell D.; Yodh, Arjun G.

    2007-05-01

    We present three-dimensional (3D) in vivo images of human breast cancer based on fluorescence diffuse optical tomography (FDOT). To our knowledge, this work represents the first reported 3D fluorescence tomography of human breast cancer in vivo. In our protocol, the fluorophore Indocyanine Green (ICG) is injected intravenously. Fluorescence excitation and detection are accomplished in the soft-compression, parallel-plane, transmission geometry using laser sources at 786 nm and spectrally filtered CCD detection. Phantom and in vivo studies confirm the signals are due to ICG fluorescence, rather than tissue autofluorescence and excitation light leakage. Fluorescence images of breast tumors were in good agreement with those of MRI, and with DOT based on endogenous contrast. Tumorto- normal tissue contrast based on ICG fluorescence was two-to-four-fold higher than contrast based on hemoglobin and scattering parameters. In total the measurements demonstrate that FDOT of breast cancer is feasible and promising.

  8. Meal-induced changes in splanchnic blood flow and oxygen uptake in middle-aged healthy humans

    DEFF Research Database (Denmark)

    Madsen, Jan Lysgård; Søndergaard, SB; Møller, Søren

    2006-01-01

    OBJECTIVE: For decades, the determination of changes in splanchnic blood flow and oxygen uptake after a meal has been used in the management of patients with suspected chronic intestinal ischaemia. However, little is known about the normal meal-induced responses. The aim of the present study...... was therefore to measure the splanchnic blood flow and oxygen uptake before and after a standardized meal in a group of middle-aged normal volunteers. MATERIAL AND METHODS: Splanchnic blood flow and oxygen uptake were determined at baseline and after a 3600-kJ mixed meal in 8 healthy women (50-70 years) and 10...... healthy men (52-76 years). Splanchnic blood flow was measured during hepatic vein catheterization by indirect Fick principle with indocyanine green as the indicator. Splanchnic oxygen uptake was calculated from splanchnic blood flow and the arteriovenous oxygen difference. RESULTS: The meal induced...

  9. Remodelling of choroidal blood flow in radiation choroidopathy

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Hideo; Muraoka, Kanemitsu; Takahashi, Kyoichi; Sutoh, Noriko [Gunma Univ., Maebashi (Japan). School of Medicine

    1997-02-01

    Two males, aged 68 and 34 years each, presented with radiation retinopathy. One had received radiation therapy to the whole brain for intracranial metastasis of lung carcinoma 29 months before. The other underwent surgery and radiation for melanoma of the upper eyelid 15 years before. When examined by indocyanine green angiography. both cases showed vasoocclusive changes in the choroid involving the choriocapillaris and major vessels in the affected fundus area. In one eye with severe retinal vascular lesions in the superior temporal quadrant, the vortex vein in the quadrant had obliterated. The venous blood in this quadrant was drained into the inferior temporal vortex vein crossing the presumed watershed zone temporal to the macula. Collaterals had formed between choroidal arteries and between choroidal veins. These cases illustrate that choroidal vascular lesions may be present in radiation retinopathy, that the former may be more pronounced than the latter and that choroidal vessels may undergo extensive remodelling to compensate for the disturbed choroidal circulation. (author)

  10. Remodelling of choroidal blood flow in radiation choroidopathy

    International Nuclear Information System (INIS)

    Kobayashi, Hideo; Muraoka, Kanemitsu; Takahashi, Kyoichi; Sutoh, Noriko

    1997-01-01

    Two males, aged 68 and 34 years each, presented with radiation retinopathy. One had received radiation therapy to the whole brain for intracranial metastasis of lung carcinoma 29 months before. The other underwent surgery and radiation for melanoma of the upper eyelid 15 years before. When examined by indocyanine green angiography. both cases showed vasoocclusive changes in the choroid involving the choriocapillaris and major vessels in the affected fundus area. In one eye with severe retinal vascular lesions in the superior temporal quadrant, the vortex vein in the quadrant had obliterated. The venous blood in this quadrant was drained into the inferior temporal vortex vein crossing the presumed watershed zone temporal to the macula. Collaterals had formed between choroidal arteries and between choroidal veins. These cases illustrate that choroidal vascular lesions may be present in radiation retinopathy, that the former may be more pronounced than the latter and that choroidal vessels may undergo extensive remodelling to compensate for the disturbed choroidal circulation. (author)

  11. Infrared-laser-based fundus angiography

    Science.gov (United States)

    Klingbeil, Ulrich; Canter, Joseph M.; Lesiecki, Michael L.; Reichel, Elias

    1994-06-01

    Infrared fundus angiography, using the fluorescent dye indocyanine green (ICG), has shown great potential in delineating choroidal neovascularization (CNV) otherwise not detectable. A digital retinal imaging system containing a diode laser for illumination has been developed and optimized to perform high sensitivity ICG angiography. The system requires less power and generates less pseudo-fluorescence background than nonlaser devices. During clinical evaluation at three retinal centers more than 200 patients, the majority of which had age-related macular degeneration, were analyzed. Laser based ICG angiography was successful in outlining many of the ill-defined or obscure CNV as defined by fluorescein angiography. The procedure was not as successful with classic CNV. ICG angiograms were used to prepare and guide laser treatment.

  12. Dye-enhanced diode laser photocoagulation of choroidal neovascularizations

    Science.gov (United States)

    Klingbeil, Ulrich; Puliafito, Carmen A.; McCarthy, Dan; Reichel, Elias; Olk, Joseph; Lesiecki, Michael L.

    1994-06-01

    Dye-enhanced diode laser photocoagulation, using the dye indocyanine green (ICG), has shown some potential in the treatment of choroidal neovascularizations (CNV). A diode laser system was developed and optimized to emit at the absorption maximum of ICG. In a clinical study at two retinal centers, more than 70 patients, the majority of which had age-related macular degeneration, were treated. Eighteen cases with ill-defined subfoveal CNV were followed an average of 11 months after laser treatment. The results show success in resolving the CNV with an average long-term preservation of visual function equal to or superior to data provided by the Macular Photocoagulation Study for confluent burns of low intensity applied to the CNV. Details of the technique and discussion of the controversies inherent in such a treatment strategy will be presented.

  13. Complementary angiographic and autofluorescence findings in pseudoxanthoma elasticum.

    Science.gov (United States)

    Lee, Thomas K M; Forooghian, Farzin; Cukras, Catherine; Wong, Wai T; Chew, Emily Y; Meyerle, Catherine B

    2010-02-01

    Pseudoxanthoma elasticum (PXE) is a systemic disease with characteristic findings on fundus examination. The fundus findings may be difficult to detect with ophthalmoscopy. A case report is described as follows. A PXE patient had subtle retinal findings on fundoscopy that were more prominently seen using a combination of both fundus autofluorescence (FAF) imaging and indocyanine green (ICG) angiography. The fundus features visualized using each of these two modalities appeared different from each other. FAF imaging and ICG angiography may be able to more prominently detect pathology at the level of the retinal pigment epithelium and Bruch's membrane, respectively. The use of these imaging modalities together may be complementary and useful in the evaluation of patients with PXE.

  14. Targeting pancreatic cancer with magneto-fluorescent theranostic gold nanoshells.

    Science.gov (United States)

    Chen, Wenxue; Ayala-Orozco, Ciceron; Biswal, Nrusingh C; Perez-Torres, Carlos; Bartels, Marc; Bardhan, Rizia; Stinnet, Gary; Liu, Xian-De; Ji, Baoan; Deorukhkar, Amit; Brown, Lisa V; Guha, Sushovan; Pautler, Robia G; Krishnan, Sunil; Halas, Naomi J; Joshi, Amit

    2014-01-01

    We report a magneto-fluorescent theranostic nanocomplex targeted to neutrophil gelatinase-associated lipocalin (NGAL) for imaging and therapy of pancreatic cancer. Gold nanoshells resonant at 810 nm were encapsulated in silica epilayers doped with iron oxide and the near-infrared (NIR) dye indocyanine green, resulting in theranostic gold nanoshells (TGNS), which were subsequently conjugated with antibodies targeting NGAL in AsPC-1-derived xenografts in nude mice. Anti-NGAL-conjugated TGNS specifically targeted pancreatic cancer cells in vitro and in vivo providing contrast for both NIR fluorescence and T2-weighted MRI with higher tumor contrast than can be obtained using long-circulating, but nontargeted, PEGylated nanoparticles. The nanocomplexes also enabled highly specific cancer cell death via NIR photothermal therapy in vitro. TGNS with embedded NIR and magnetic resonance contrasts can be specifically targeted to pancreatic cancer cells with expression of early disease marker NGAL, and enable molecularly targeted imaging and photothermal therapy.

  15. Quantitative radiocardiography by single-probe counting using sup(99m)technetium albumin

    International Nuclear Information System (INIS)

    Man in 't Veld, A.J.; Wenting, G.J.; Verhoeven, R.P.; Schalekamp, M.A.D.H.

    1978-01-01

    Quantitative radiocardiography with sup(99m)Technetium albumin, using a single probe for percordial counting of radioactivity is a non-invasive technique to measure cardiac output. sup(99m)Technetium pertechnetate is bound to albumin by electrolytic complexation. Preparations of sup(99m)Technetium albumin showed small percentages of free radioactivity. In-vivo stability of the complex was confirmed by comparison with distribution volumes of 131 Iodine albumin and sup(113m)Indium transferrin. The isotope dilution cardiac output technique was validated by comparison with a classical indocyanine green dilution method. Results obtained by peripheral intravenous injection of the isotope were not different from those after intracardiac injection. Exact localization of the collimator over the heart was not critical. Duplicate measurements showed good reproducibility. Examples of serial measurements in patients with hyperthyroidism, primary aldosteronism and essential hypertinsion are given. The method is reliable, accurate and safe and causes no discomfort to the patient. (C.F.)

  16. Application of OCT angiography in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ai-Ping Yang

    2017-11-01

    Full Text Available Optical coherence tomography angiography(OCTAis a new technology of angiography in recent years. In addition to the advantages of traditional OCT, it can observe blood flow in different retinal and choroidal segmentation slab. By using the pseudo-color, abnormal vascular structure can be distinguished from normal vascular structure of the retina. Dye injection is not needed with OCTA, which is different from fundus fluorescein angiography(FFAand indocyanine green angiography(ICGA. OCTA provides more and more accurate blood flow information. However, like other biometric technology, OCTA has its limitations and shortcomings. This review will analyze and summarize the operating principle of OCTA, its application in ophthalmology, as well as its advantages and limitations.

  17. Decompression Retinopathy after ExPRESS Shunt Implantation for Steroid-Induced Ocular Hypertension: A Case Report

    Directory of Open Access Journals (Sweden)

    Khawla Abu Samra

    2011-01-01

    Full Text Available Purpose. To present a unique case of decompression retinopathy after the implantation of ExPRESS drainage device. Method. A 25-year-old female patient underwent implantation of ExPRESS drainage device in the left eye for the management of steroid-induced ocular hypertension. Results. On the postoperative day one, best-corrected visual acuity in the left eye was 20/50. Fundus examination revealed diffuse intraretinal hemorrhages, some white-centered, throughout the retina. There was also marked tortuosity to the retinal vasculature and no evidence of choroidal effusion. Intravenous fluorescein angiography and indocyanine green did not contribute to the aetiopathogenesis. Conclusion. Decompression retinopathy can occur following the implantation of ExPRESS drainage device. It is very important to be aware of this complication in patients with relatively high intraocular pressure who is planned for filtration surgery, including the ExPRESS implant.

  18. Quantitative radionuclide angiocardiography

    International Nuclear Information System (INIS)

    Scholz, P.M.; Rerych, S.K.; Moran, J.F.; Newman, G.E.; Douglas, J.M.; Sabiston, D.C. Jr.; Jones, R.H.

    1980-01-01

    This study introduces a new method for calculating actual left ventricular volumes and cardiac output from data recorded during a single transit of a radionuclide bolus through the heart, and describes in detail current radionuclide angiocardiography methodology. A group of 64 healthy adults with a wide age range were studied to define the normal range of hemodynamic parameters determined by the technique. Radionuclide angiocardiograms were performed in patients undergoing cardiac catherization to validate the measurements. In 33 patients studied by both techniques on the same day, a close correlation was documented for measurement of ejection fraction and end-diastolic volume. To validate the method of volumetric cardiac output calcuation, 33 simultaneous radionuclide and indocyanine green dye determinations of cardiac output were performed in 18 normal young adults. These independent comparisons of radionuclide measurements with two separate methods document that initial transit radionuclide angiocardiography accurately assesses left ventricular function

  19. Confinement of carbon dots localizing to the ultrathin layered double hydroxides toward simultaneous triple-mode bioimaging and photothermal therapy.

    Science.gov (United States)

    Weng, Yangziwan; Guan, Shanyue; Lu, Heng; Meng, Xiangmin; Kaassis, Abdessamad Y; Ren, Xiaoxue; Qu, Xiaozhong; Sun, Chenghua; Xie, Zheng; Zhou, Shuyun

    2018-07-01

    It is a great challenge to develop multifunctional nanocarriers for cancer diagnosis and therapy. Herein, versatile CDs/ICG-uLDHs nanovehicles for triple-modal fluorescence/photoacoustic/two-photon bioimaging and effective photothermal therapy were prepared via a facile self-assembly of red emission carbon dots (CDs), indocyanine green (ICG) with the ultrathin layered double hydroxides (uLDHs). Due to the J-aggregates of ICG constructed in the self-assembly process, CDs/ICG-uLDHs was able to stabilize the photothermal agent ICG and enhanced its photothermal efficiency. Furthermore, the unique confinement effect of uLDHs has extended the fluorescence lifetime of CDs in favor of bioimaging. Considering the excellent in vitro and in vivo phototherapeutics and multimodal imaging effects, this work provides a promising platform for the construction of multifunctional theranostic nanocarrier system for the cancer treatment. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Large-spot subthreshold transpupillary thermotherapy for chronic serous macular detachment

    Directory of Open Access Journals (Sweden)

    Giuseppe Lo Giudice

    2011-03-01

    Full Text Available Giuseppe Lo Giudice1, Valentina de Belvis2, Marco Tavolato1, Alessandro Galan11San Paolo Ophthalmic Center, San Antonio Hospital, Padova, Italy; 2Paediatric Low Vision Center, Paediatric Rare Eye Disease Center, Department of Paediatrics, University of Padova, ItalyPurpose: To report the effect of subthreshold transpupillary thermotherapy (TTT in treating serous detachment of the neurosensory retina secondary to chronic central serous chorioretinopathy (CCSC.Methods: Seven eyes from five patients with CCSC, persistent serous detachment of the neurosensory retina and a clinical course of between 12 and 60 months were treated. All eyes received large-spot TTT guided by indocyanine green angiography (ICGA. Subthreshold TTT was performed using an 810 nm diode laser with a spot size of 3.0 mm (power was set at 350 mW. Treatment was applied for 60 seconds to the areas of choroidal hyperfluorescence on ICGA.Results: The mean number of TTT sessions was 1.4 ± 0.5. All eyes were followed up for at least 6 months (mean 9.6 ± 3.2 standard deviation; range 6–12 months. The mean logarithm of the minimum angle of resolution best-corrected visual acuity was significantly better compared with baseline. All TTT-treated eyes had stable or improved vision (P < 0.001. Mean optical coherence tomography (OCT central foveal thickness was significantly lower in all patients (P < 0.001 compared with pretreatment OCT, with a reduction in subretinal fluid and resolution of serous detachment associated with anatomical fovea restoration. No patient had any treatment-related side effects.Conclusion: Modified subthreshold TTT appears to have a beneficial effect in treating patients with CCSC and persistent neurosensory detachment. The encouraging results and lack of visually significant complications suggest that further investigation is warranted.Keywords: central serous chorioretinopathy, indocyanine green angiography, neurosensory detachment, transpupillary

  1. A feasibility study of NIR fluorescent image-guided surgery in head and neck cancer based on the assessment of optimum surgical time as revealed through dynamic imaging

    Directory of Open Access Journals (Sweden)

    Yokoyama J

    2013-04-01

    Full Text Available Junkichi Yokoyama,* Mitsuhisa Fujimaki,* Shinichi Ohba, Takashi Anzai, Ryota Yoshii, Shin Ito, Masataka Kojima, Katsuhisa IkedaDepartment of Otolaryngology-Head and Neck Surgery, Juntendo University School of Medicine, Tokyo, Japan *These authors contributed equally to this study Background: In order to minimize surgical stress and preserve organs, endoscopic or robotic surgery is often performed when conducting head and neck surgery. However, it is impossible to physically touch tumors or to observe diffusely invaded deep organs through the procedure of endoscopic or robotic surgery. In order to visualize and safely resect tumors even in these cases, we propose using an indocyanine green (ICG fluorescence method for navigation surgery in head and neck cancer. Objective: To determine the optimum surgical time for tumor resection after the administration of ICG based on the investigation of dynamic ICG fluorescence imaging. Methods: Nine patients underwent dynamic ICG fluorescence imaging for 360 minutes, assessing tumor visibility at 10, 30, 60, 120, 180, and 360 minutes. All cases were scored according to near-infrared (NIR fluorescence imaging visibility scored from 0 to 5. Results: Dynamic NIR fluorescence imaging under the HyperEye Medical System indicated that the greatest contrast in fluorescent images between tumor and normal tissue could be observed from 30 minutes to 1 hour after the administration of ICG. The optimum surgical time was determined to be between 30 minutes to 2 hours after ICG injection. These findings are particularly useful for detection and safe resection of tumors invading the parapharyngeal space. Conclusion: ICG fluorescence imaging is effective for the detection of head and neck cancer. Preliminary findings suggest that the optimum timing for surgery is from 30 minutes to 2 hours after the ICG injection. Keywords: indocyanine green (ICG, navigation surgery, robotic surgery, endoscopic surgery, minimally invasive

  2. A New Composite Eyeball-Periorbital Transplantation Model in Humans: An Anatomical Study in Preparation for Eyeball Transplantation.

    Science.gov (United States)

    Siemionow, Maria; Bozkurt, Mehmet; Zor, Fatih; Kulahci, Yalcin; Uygur, Safak; Ozturk, Can; Djohan, Risal; Papay, Frank

    2018-04-01

    Vascularized composite allotransplantation offers a new hope for restoration of orbital content and perhaps vision. The aim of this study was to introduce a new composite eyeball-periorbital transplantation model in fresh cadavers in preparation for composite eyeball allotransplantation in humans. The composite eyeball-periorbital transplantation flap borders included the inferior border, outlined by the infraorbital rim; the medial border, created by the nasal dorsum; the lateral border, created by the lateral orbital rim; and the superior border, created by the superior part of the eyebrow. The pedicle of the flap included the facial artery, superficial temporal artery, and external jugular vein. The skin and subcutaneous tissues of the periorbital region were dissected and the bony tissue was reached. A coronal incision was performed and the frontal lobe of the brain was reached by means of frontal osteotomy. Ophthalmic and oculomotor nerves were also included in the flap. After a "box osteotomy" around the orbit, the dissection was completed. Methylene blue and indocyanine green injection (SPY Elite System) was performed to show the integrity of the vascular territories after facial flap harvest. Adequate venous return was observed within the flap after methylene blue dye injection. Laser-assisted indocyanine green angiography identified a well-defined vascular network within the entire composite eyeball-periorbital transplantation flap. For the first time, a novel composite eyeball-periorbital transplantation model in human cadavers was introduced. Good perfusion of the flap confirmed the feasibility of composite eyeball-periorbital transplantation in the clinical setting. Although harvesting of the flap is challenging, it introduces a new option for reconstruction of the periorbital region including the eyeball.

  3. Preliminary results of laser-assisted sealing of hand-sewn canine esophageal anastomoses

    Science.gov (United States)

    Auteri, Joseph S.; Oz, Mehmet C.; Sanchez, Juan A.; Bass, Lawrence S.; Jeevanandam, Valluvan; Williams, Matthew R.; Smith, Craig R.; Treat, Michael R.

    1991-07-01

    Dehiscence rates of esophageal anastomoses range between 5 and 20%. Causative factors include ischemia, tension, foreign body reaction, microabscesses, and the negative pressure within the thoracic cavity. Laser assisted tissue sealing (LATS) has been shown to decrease anastomotic leakage rates in other tissues. Using a canine model the efficacy of LATS in enhancing single layer hand swen intrathoracic esophageal anastomoses was assessed. Via a left thoracotomy, paired two centimeter transverse incisions (one laser sealed, one control) were made in the proximal and distal esophagus in nine dogs. Both were sewn using a single layer of 4-0 polyglycolic acid. A combination of albumin (0.2 cc), sodium hyaluronate (0.4 cc), and indocyanine green (1 gtt) was applied to one of the randomly chosen hand sewn repairs. The albumin/hyaluronate combination is used to provide a protein matrix across the anastomosis for ingrowth of fibroblasts. Indocyanine green dye selectively absorbs at OM805 nm which matches the output of the diode laser (808 +/- 1 nm), thus improving uptake of laser energy by the targeted tissues. The anastomosis was then exposed to continuous wave diode laser energy for OM2 minutes at a power density of 9.6 W/cm2. The esophagus was recovered either at the time of sealing or two days postoperatively and infused with saline under pressure. Bursting pressures were considered the point of initial saline leakage. At time 0 there was no significant difference in bursting pressures between the LATS group and controls. However, at two days postoperatively controls burst at 121 +/- 14 mmHg while the laser assisted anastomoses burst at 295 +/- 35 mmHg (p anastomoses revealed minimal thermal injury to the mucosal surface initially, with some regeneration of mucosal lining at two days postoperatively. No foreign body reaction to the solder was noted. Laser reinforcement of single layer hand sewn esophageal anastomoses appears to increase bursting pressure and may result

  4. CHARACTERISTICS OF EPIRETINAL MEMBRANE REMNANT EDGE BY OPTICAL COHERENCE TOMOGRAPHY AFTER PARS PLANA VITRECTOMY.

    Science.gov (United States)

    Gaber, Raouf; You, Qi Sheng; Muftuoglu, Ilkay Kilic; Alam, Mostafa; Tsai, Frank F; Mendoza, Nadia; Freeman, William R

    2017-11-01

    To evaluate the incidence, characteristics, and the progression of epiretinal membrane (ERM) remnant edge seen by optical coherence tomography after ERM peeling. A retrospective chart review was conducted for 86 eyes of 85 consecutive patients who were diagnosed with ERM and underwent pars plana vitrectomy for epiretinal membrane peeling between 2013 and 2014. Data collected and analyzed included age, gender, preoperative and postoperative visual acuity, use of indocyanine green dye to stain internal limiting membrane, tamponade used after vitrectomy, ERM edge boundaries, presence of cystoid macular edema, and central foveal thickness. An ERM remnant edge was detected in 33/86 study eyes (38.4%) at the first postoperative optical coherence tomography scan. Compared with those without an ERM remnant, patients with an ERM remnant after surgery were significantly older at baseline and had a higher incidence of ERM recurrence at their last visit. They were not significantly different in terms of gender, preoperative and postoperative visual acuity, reduction of central foveal thickness from baseline, proportion of eyes with preoperative ERM elevation on optical coherence tomography, presence of macular edema before surgery, intraoperative use of indocyanine green staining for ILM peeling, or tamponade used. Based on the edge morphology, we classified the ERM remnant into three types: Type 1 was flat and blended with the retina (14/33 eyes, 42.4%), Type 2 was flat but stepped (17/33 eyes, 51.5%), and Type 3 was elevated (2/33 eyes, 6.0%). A significantly higher risk of ERM recurrence was seen in Type 2 and Type 3 ERM remnants (75% and 100%, respectively) than Type 1 ERM remnants (10%). An ERM remnant edge was detected by optical coherence tomography after ERM peeling in 38.4% of eyes. The presence of a postoperative ERM edge was associated with a higher risk of ERM recurrence, particularly in Type 2 and Type 3 ERM remnants.

  5. Synovitis in mice with inflammatory arthritis monitored with quantitative analysis of dynamic contrast-enhanced NIR fluorescence imaging using iRGD-targeted liposomes as fluorescence probes

    Directory of Open Access Journals (Sweden)

    Wu H

    2018-03-01

    Full Text Available Hao Wu,1,2,* Haohan Wu,1,2,* Yanni He,1 Zhen Gan,2 Zhili Xu,1,2 Meijun Zhou,1,2 Sai Liu,1,2 Hongmei Liu1 1Department of Ultrasonography, Guangdong Second Provincial General Hospital Affiliated to Southern Medical University, Guangzhou, China; 2Department of Ultrasonography, The Third Affiliated Hospital of Southern Medical University, Guangzhou, China *These authors contributed equally to this work Background: Rheumatoid arthritis (RA is a common inflammatory disorder characterized primarily by synovitis and pannus formation in multiple joints, causing joints destruction and irreversible disability in most cases. Early diagnosis and effective therapy monitoring of RA are of importance for achieving the favorable prognosis. Methods: We first prepared the targeted fluorescence probes, and then explored the feasibility of near-infrared (NIR fluorescence molecular imaging to detect and evaluate the RA via the targeted fluorescence probes by quantitative analysis in this study. Results: The targeted fluorescence probes (indocyanine green-liposomes decorated with iRGD peptide [iLPs] was successfully prepared. The quantitative analysis found that strong fluorescence signal was detected in inflamed paws and the fluorescence signal in iLPs group was 3.03-fold higher than that in non-targeted (indocyanine green-liposomes decorated without iRGD peptide [LPs] group (P<0.01 at 15 min after injection, whereas the fluorescence signal from iLPs signal can almost not be observed in the non-inflamed paws, showing the high sensitivity and accuracy for arthritis by the NIR fluorescence imaging based on iLPs. Conclusion: The NIR fluorescence imaging by iLPs may facilitate improved arthritis diagnosis and early assessment of the disease progression by providing an in vivo characterization of angiogenesis in inflammatory joint diseases. Keywords: rheumatoid arthritis, synovitis, diagnosis, near-infrared fluorescence imaging, iRGD-targeted probes

  6. Preoperative Estimation of Future Remnant Liver Function Following Portal Vein Embolization Using Relative Enhancement on Gadoxetic Acid Disodium-Enhanced Magnetic Resonance Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Yozo [Department of Radiology, Aichi Medical University, Aichi 480-1195 (Japan); Department of Diagnostic and Interventional Radiology, Aichi Cancer Center Hospital, Nagoya 464-8681 (Japan); Matsushima, Shigeru; Inaba, Yoshitaka [Department of Diagnostic and Interventional Radiology, Aichi Cancer Center Hospital, Nagoya 464-8681 (Japan); Sano, Tsuyoshi [Department of Gastroenterological Surgery, Aichi Cancer Center Hospital, Nagoya 464-8681 (Japan); Yamaura, Hidekazu; Kato, Mina [Department of Diagnostic and Interventional Radiology, Aichi Cancer Center Hospital, Nagoya 464-8681 (Japan); Shimizu, Yasuhiro; Senda, Yoshiki [Department of Gastroenterological Surgery, Aichi Cancer Center Hospital, Nagoya 464-8681 (Japan); Ishiguchi, Tsuneo [Department of Radiology, Aichi Medical University, Aichi 480-1195 (Japan)

    2015-11-01

    To retrospectively evaluate relative enhancement (RE) in the hepatobiliary phase of gadoxetic acid disodium-enhanced magnetic resonance (MR) imaging as a preoperative estimation of future remnant liver (FRL) function in a patients who underwent portal vein embolization (PVE). In 53 patients, the correlation between the indocyanine green clearance (ICG-K) and RE imaging was analyzed before hepatectomy (first analysis). Twenty-three of the 53 patients underwent PVE followed by a repeat RE imaging and ICG test before an extended hepatectomy and their results were further analyzed (second analysis). Whole liver function and FRL function were calculated on the MR imaging as follows: RE x total liver volume (RE Index) and FRL-RE x FRL volume (Rem RE Index), respectively. Regarding clinical outcome, posthepatectomy liver failure (PHLF) was evaluated in patients undergoing PVE. Indocyanine green clearance correlated with the RE Index (r = 0.365, p = 0.007), and ICG-K of FRL (ICG-Krem) strongly correlated with the Rem RE Index (r = 0.738, p < 0.001) in the first analysis. Both the ICG-Krem and the Rem RE Index were significantly correlated after PVE (r = 0.508, p = 0.013) at the second analysis. The rate of improvement of the Rem RE Index from before PVE to after PVE was significantly higher than that of ICG-Krem (p = 0.014). Patients with PHLF had a significantly lower Rem RE Index than patients without PHLF (p = 0.023). Relative enhancement imaging can be used to estimate FRL function after PVE.

  7. Estimating functional liver reserve following hepatic irradiation: Adaptive normal tissue response models

    International Nuclear Information System (INIS)

    Stenmark, Matthew H.; Cao, Yue; Wang, Hesheng; Jackson, Andrew; Ben-Josef, Edgar; Ten Haken, Randall K.; Lawrence, Theodore S.; Feng, Mary

    2014-01-01

    Purpose: To estimate the limit of functional liver reserve for safe application of hepatic irradiation using changes in indocyanine green, an established assay of liver function. Materials and methods: From 2005 to 2011, 60 patients undergoing hepatic irradiation were enrolled in a prospective study assessing the plasma retention fraction of indocyanine green at 15-min (ICG-R15) prior to, during (at 60% of planned dose), and after radiotherapy (RT). The limit of functional liver reserve was estimated from the damage fraction of functional liver (DFL) post-RT [1 − (ICG-R15 pre-RT /ICG-R15 post-RT )] where no toxicity was observed using a beta distribution function. Results: Of 48 evaluable patients, 3 (6%) developed RILD, all within 2.5 months of completing RT. The mean ICG-R15 for non-RILD patients pre-RT, during-RT and 1-month post-RT was 20.3%(SE 2.6), 22.0%(3.0), and 27.5%(2.8), and for RILD patients was 6.3%(4.3), 10.8%(2.7), and 47.6%(8.8). RILD was observed at post-RT damage fractions of ⩾78%. Both DFL assessed by during-RT ICG and MLD predicted for DFL post-RT (p < 0.0001). Limiting the post-RT DFL to 50%, predicted a 99% probability of a true complication rate <15%. Conclusion: The DFL as assessed by changes in ICG during treatment serves as an early indicator of a patient’s tolerance to hepatic irradiation

  8. Differential uptake of [18F]FET and [3H]L-methionine in focal cortical ischemia

    International Nuclear Information System (INIS)

    Salber, Dagmar; Stoffels, Gabriele; Pauleit, Dirk; Reifenberger, Guido; Sabel, Michael; Shah, Nadim Jon; Hamacher, Kurt; Coenen, Heinz H.; Langen, Karl-Josef

    2006-01-01

    Amino acids such as [ 11 C-methyl]L-methionine are particularly useful in brain tumor diagnosis, but unspecific uptake (e.g., in cerebral ischemia) has been reported. O-(2-[ 18 F]fluoroethyl)-L-tyrosine ([ 18 F]FET) shows a clinical potential similar to that of L-methionine (MET) in brain tumor diagnosis but is applicable on a wider clinical scale. The aim of this study was to evaluate the uptake of [ 18 F]FET and [ 3 H]MET in focal cortical ischemia in rats by dual-tracer autoradiography. Methods: Focal cortical ischemia was induced in 25 CDF rats using the photothrombosis (PT) model. At different time points up to 6 weeks after the induction of PT, [ 18 F]FET and [ 3 H]MET were injected intravenously. Additionally, contrast-enhanced magnetic resonance imaging (MRI) was performed in 10 animals. One hour after tracer injection, brains were cut in coronal sections and evaluated by dual-tracer autoradiography. Lesion-to-brain (L/B) ratios were calculated by dividing the maximal uptake in the lesion by the mean uptake in the brain. An L/B ratio of >2.0 was considered indicative of pathological uptake. Histological slices were stained by cresyl violet and supplemented by immunostainings for glial fibrillary acidic protein (GFAP) and CD68 in selected cases. Results: A variably increased uptake of both tracers was observed in the PT lesion and its demarcation zone up to 7 days after PT for [ 18 F]FET and up to 6 weeks for [ 3 H]MET. The cutoff level of 2.0 was exceeded in 12/25 animals for [ 18 F]FET and in 18/25 animals for [ 3 H]MET. Focally increased tracer uptake matched contrast enhancement in MRI in 3/10 cases for [ 18 F]FET and in 5/10 cases for [ 3 H]MET. Immunohistochemical staining in lesions with differential uptake of [ 18 F]FET and [ 3 H]MET revealed that selective uptake of [ 18 F]FET was associated with GFAP-positive astrogliosis while selective [ 3 H]MET uptake correlated with CD68-positive macrophage infiltration. Conclusions: [ 18 F]FET, like [ 3 H

  9. Vasculopatia polipoidal idiopática da coróide: aspectos extremos da evolução da doença em um paciente - Relato de caso Idiopathic polypoidal choroidal vasculopathy: its extreme aspects in one patient - Case report

    Directory of Open Access Journals (Sweden)

    Ieda Maria Alexandre Barreira

    2005-04-01

    Full Text Available O artigo descreve um caso de vasculopatia polipoidal idiopática da coróide (VPIC e demonstra o papel relevante da indocianinografia no diagnóstico diferencial com outras causas de neovascularização subretiniana, particularmente degeneração macular relacionada à idade (DMRI, bem como avalia os aspectos extremos na evolução da doença em um único paciente. Paciente de 54 anos, sexo masculino, cor parda, com queixas de baixa de acuidade visual súbita em OD, foi submetido a exame oftalmológico, pelo qual se constatou hemorragia vítrea em OD e, posteriormente, descolamento sero-hemorrágico do epitélio pigmentário da retina em OE. A angiofluoresceinografia e indocianinografia mostraram quadro compatível com vasculopatia polipoidal idiopática da coróide. O paciente foi submetido a vitrectomia via pars plana em OD e foi acompanhado por período de 5 meses, evoluindo com perda de visão secundária a descolamento de retina e cicatriz macular disciforme em OD. No olho contralateral, ocorreu involução da vasculopatia com preservação de acuidade visual 20/25. A vasculopatia polipoidal idiopática da coróide é entidade clínica cujas anormalidades do fundo de olho se sobrepõem às manifestações da degeneração macular relacionada à idade exsudativa. A indocianinografia é de vital importância no diagnóstico diferencial entre as duas doenças que tem evolução e prognóstico distintos. Além disso, consideramos este caso muito ilustrativo pelas diferentes nuances com que a doença se manifestou e evoluiu em um único paciente.To describe a case of idiopathic polypoidal choroidal vasculopathy and the role of indocyanine green angiography findings in the differential diagnosis of exsudative maculopathies, particularly with age-related macular degeneration, and the extreme evolution of idiopathic polypoidal choroidal vasculopathy in one patient. A patient with vitreous hemorrhage was examined and evaluated by fluorescein and

  10. Comparison of the application of three different methods in the diagnosis of early diabetic retinopathy%三种不同造影方式在糖尿病性视网膜病变诊断中的应用对比

    Institute of Scientific and Technical Information of China (English)

    夏蓉; 冯春阳; 周莅斌

    2017-01-01

    目的:比较分析虹膜荧光血管造影(iris fluorescein angiography,IFA)联合眼底荧光血管造影(fundus fluorescein angiography,FFA)、吲哚菁绿血管造影(indocyanine green angiogrsphy,ICGA)和FFA在早期糖尿病性视网膜病变(diabetic retinitis,DR)中的诊断价值.方法:选择2015-08/2016-08期间我院收治的DR患者70例136眼,全部患者分别接受ICGA、FFA、IFA+ FFA检查,分析三种造影方式的检出结果.结果:FFA检出病变120眼(88.2%),ICGA检出病变124眼(91.2%),IFA+FFA检出病变130眼(95.6%),三种检查方法病变检出率比较,差异无统计学意义(P>0.05);FFA检出48眼出现新生血管,18眼玻璃体积血,38眼黄斑水肿,16眼无灌注区;ICGA检出49眼新生血管,38眼黄斑水肿,17眼玻璃体积血,20眼无灌注区;IFA+FFA检出17眼增殖性糖尿病性虹膜病变(DI),22眼非增殖性DI,5眼NVG,92眼无DI.结论:在DR诊断中,IFA+ FFA、FFA、ICGA均具有不错的诊断价值,但IFA+ FFA可及时发现合并的糖尿病虹膜病变,为及时治疗提供帮助.%AIM:To compare and analyze the diagnostic value of iris fluorescein angiography (IFA) combined with fundus fluorescein angiography (FFA),indocyanine green angiograph (ICGA),fundus fluorescein angiography in the diagnosis of early diabetic retinitis (DR).METHODS:Totally 70 patients (136 eyes) with early diabetic retinopathy enrolled in our hospital from August 2015 to August 2016 were selected in this study.All patients were respectively treated with ICGA,FFA and IFA+FFA,and the detection results of three kinds of imaging methods were analyzed.RESULTS:There were 120 pathological eyes (88.2%)were detected by FFA,124 pathological eyes (91.2%)were detected by ICGA,130 pathological eyes (95.6%)were detected by IFA+ FFA,and there was no significant difference in the detection rate between the three methods (P>0.05).FFA detected 48 eyes with neovascularization,18 eyes with vitreous hemorrhage,38 eyes with macular edema,16

  11. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery.

    Science.gov (United States)

    KleinJan, Gijs H; van den Berg, Nynke S; de Jong, Jeroen; Wit, Esther M; Thygessen, Helene; Vegt, Erik; van der Poel, Henk G; van Leeuwen, Fijs W B

    2016-07-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-(99m)Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-(99m)Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  12. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    Energy Technology Data Exchange (ETDEWEB)

    KleinJan, Gijs H. [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Berg, Nynke S. van den [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Jong, Jeroen de [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Pathology, Amsterdam (Netherlands); Wit, Esther M.; Poel, Henk G. van der [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Thygessen, Helene [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Biostatistics, Amsterdam (Netherlands); Vegt, Erik [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Leeuwen, Fijs W.B. van [Leiden University Medical Hospital, Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands)

    2016-07-15

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green-{sup 99m}Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green-{sup 99m}Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs

  13. Multimodal hybrid imaging agents for sentinel node mapping as a means to (re)connect nuclear medicine to advances made in robot-assisted surgery

    International Nuclear Information System (INIS)

    KleinJan, Gijs H.; Berg, Nynke S. van den; Jong, Jeroen de; Wit, Esther M.; Poel, Henk G. van der; Thygessen, Helene; Vegt, Erik; Leeuwen, Fijs W.B. van

    2016-01-01

    Radical prostatectomy and complementary extended pelvic lymph node dissection (ePLND) of sentinel lymph nodes (SNs) and non-sentinel lymph nodes (LNs) at risk of containing metastases are increasingly being performed using high-tech robot-assisted approaches. Although this technological evolution has clear advantages, the physical nature of robotic systems limits the integrated use of routine radioguided surgery technologies. Hence, engineering effort in robotics are focused on the integration of fluorescence guidance technologies. Using the hybrid SN tracer indocyanine green- 99m Tc-nanocolloid (radioactive and fluorescent), for the first time in combination with a robot-integrated laparoscope, we investigated whether the robot-assisted approach affects the accuracy of fluorescence detection of SNs identified preoperatively using nuclear medicine. The study included 55 patients (Briganti nomogram-based risk >5 % on LN metastases) scheduled for robot-assisted radical prostatectomy, SN biopsy and ePLND. Following indocyanine green- 99m Tc-nanocolloid injection, preoperative nuclear imaging (lymphoscintigraphy and SPECT/CT) was used to locate the SN(s). The fluorescence laparoscope was used intraoperatively to identify the SN(s) with standard fluorescence settings (in 50 patients) and with customized settings (in 5 patients). The number and location of the SNs, the radioactive, fluorescence (both in vivo and ex vivo) and tumour status of the resected SNs/LNs, and postoperative complications were recorded and analysed. Combined, preoperative lymphoscintigraphy and SPECT/CT imaging identified 212 SNs (median 4 per patient). Intraoperative fluorescence imaging using standard fluorescence settings visualized 80.4 % (148/184 SNs; 50 patients; ex vivo 97.8 %). This increased to 85.7 % (12/14 SNs; 5 patients; ex vivo 100 %) with customized fluorescence settings. SPECT/CT images provided guidance towards the residual SNs. Ex vivo all removed SNs were radioactive. SNs were

  14. A Wearable Goggle Navigation System for Dual-Mode Optical and Ultrasound Localization of Suspicious Lesions: Validation Studies Using Tissue-Simulating Phantoms and an Ex Vivo Human Breast Tissue Model.

    Directory of Open Access Journals (Sweden)

    Zeshu Zhang

    Full Text Available Surgical resection remains the primary curative treatment for many early-stage cancers, including breast cancer. The development of intraoperative guidance systems for identifying all sites of disease and improving the likelihood of complete surgical resection is an area of active ongoing research, as this can lead to a decrease in the need of subsequent additional surgical procedures. We develop a wearable goggle navigation system for dual-mode optical and ultrasound imaging of suspicious lesions. The system consists of a light source module, a monochromatic CCD camera, an ultrasound system, a Google Glass, and a host computer. It is tested in tissue-simulating phantoms and an ex vivo human breast tissue model. Our experiments demonstrate that the surgical navigation system provides useful guidance for localization and core needle biopsy of simulated tumor within the tissue-simulating phantom, as well as a core needle biopsy and subsequent excision of Indocyanine Green (ICG-fluorescing sentinel lymph nodes. Our experiments support the contention that this wearable goggle navigation system can be potentially very useful and fully integrated by the surgeon for optimizing many aspects of oncologic surgery. Further engineering optimization and additional in vivo clinical validation work is necessary before such a surgical navigation system can be fully realized in the everyday clinical setting.

  15. Usefulness of granular BCAA after hepatectomy for liver cancer complicated with liver cirrhosis.

    Science.gov (United States)

    Togo, Shinji; Tanaka, Kuniya; Morioka, Daisuke; Sugita, Mitsutaka; Ueda, Michio; Miura, Yasuhiko; Kubota, Toru; Nagano, Yasuhiko; Matsuo, Kenichi; Endo, Itaru; Sekido, Hitoshi; Shimada, Hiroshi

    2005-04-01

    Nutritional disturbances such as ascites and hypoalbuminemia frequently arise after hepatectomy for liver cancer with liver cirrhosis. We examined the possibility of maintaining a favorable state of nutrition by outpatient administration of branched-chain amino acid (BCAA) granules. Forty-three patients who had gross liver cirrhosis complicated by liver cancer and underwent surgery up to May 2002 were given BCAA granules (n = 21, BCAA group) or no granules (n = 22, control group). 1) Background details such as age, sex, surgical technique, blood loss, and duration of surgery showed no significant differences. 2) Among objective findings, improvement of ascites and edema tended to occur sooner in the BCAA group, but without a significant difference. 3) Although serum albumin recovered its preoperative value 9 mo after surgery in the control group, only 6 mo was required for recovery in the BCAA group. Total protein showed similar changes, but neither group showed any difference in changes of aspartate aminotransferase, alanine transferase, or platelets. 4) One year postoperatively, the change from the preoperative indocyanine green retention rate at 15 min after intravenous administration tended to be worse in the control group, but not significantly so. 5) In the BCAA group, hyaluronic acid and type IV collagen 7S improved significantly sooner than in the control group. BCAA supplementation after hepatectomy promotes rapid improvement in protein metabolism and inhibits progression to liver cirrhosis. Administration of BCAA after hepatectomy is considered beneficial to a patient's nutritional state.

  16. Purification of optical imaging ligand-Cybesin by high-speed counter-current chromatography

    Science.gov (United States)

    Ma, Zhiyong; Ma, Ying; Sun, Xilin; Ye, Yunpeng; Shen, Baozhong; Chen, Xiaoyuan; Ito, Yoichiro

    2010-01-01

    Fluorescent Cybesin (Cypate-Bombesin Peptide Analogue Conjugate) was synthesized from Indocyanine Green (ICG) and the bombesin receptor ligand as a contrast agent for detecting pancreas tumors. However, the LC–MS analysis indicated that the target compound was only a minor component in the reaction mixture. Since preparative HPLC can hardly separate such a small amount of the target compound directly from the original crude reaction mixture without a considerable adsorptive loss onto the solid support, high-speed counter-current chromatography (HSCCC) was used for purification since the method uses no solid support and promises high sample recovery. A suitable two-phase solvent system composed of hexane/ethyl acetate/methanol/methyl t.-butyl ether/acetonitrile/water) at a volume ratio of 1:1:1:4:4:7 was selected based on the partition coefficient of Cybesin (K ≈ 0.9) determined by LC–MS. The separation was performed in two steps using the same solvent system with lower aqueous mobile phase. From 400 mg of the crude reaction mixture the first separation yielded 7.7 mg of fractions containing the target compound at 12.8% purity, and in the second run 1 mg of Cybesin was obtained at purity of 94.0% with a sample recovery rate of over 95% based on the LC–MS Analysis. PMID:20933483

  17. Tuberculosis.

    Science.gov (United States)

    Tabbara, Khalid F

    2007-11-01

    The purpose of this report is to present an update on the manifestations and management of ocular tuberculosis. Tuberculosis affects one-third of the world's population. The incidence of tuberculosis has increased with the increase in the HIV infected population. Following a resurgence of the disease in the US, the incidence has recently declined. Patients may develop scleritis that can be focal, nodular or diffuse with or without keratitis. Anterior granulomatous uveitis may occur. The posterior segment reveals vitritis, choroiditis, and can mimic serpiginous choroiditis and other entities. Patients who are immunosuppressed or HIV infected may develop active mycobacterial disease in the eye leading to rapid destruction of the ocular structures. The diagnosis of ocular tuberculosis is made by isolation of Mycobacterium tuberculosis on Löwestein-Jensen medium or by PCR. The diagnosis is supported by the clinical findings, imaging techniques including optical coherence tomography, fluorescein angiography, indocyanine green and ultrasonography. Tuberculin skin test helps to confirm the diagnosis. Ocular tuberculosis may occur in the absence of pulmonary disease. Patients present with a spectrum of clinical signs. The disease may mimic several clinical entities. Early diagnosis and prompt treatment of ocular tuberculosis may prevent ocular morbidity and blindness.

  18. Dual-wavelength OR-PAM with compressed sensing for cell tracking in a 3D cell culture system

    Science.gov (United States)

    Huang, Rou-Xuan; Fu, Ying; Liu, Wang; Ma, Yu-Ting; Hsieh, Bao-Yu; Chen, Shu-Ching; Sun, Mingjian; Li, Pai-Chi

    2018-02-01

    Monitoring dynamic interactions of T cells migrating toward tumor is beneficial to understand how cancer immunotherapy works. Optical-resolution photoacoustic microscope (OR-PAM) can provide not only high spatial resolution but also deeper penetration than conventional optical microscopy. With the aid of exogenous contrast agents, the dual-wavelength OR-PAM can be applied to map the distribution of CD8+ cytotoxic T lymphocytes (CTLs) with gold nanospheres (AuNS) under 523nm laser irradiation and Hepta1-6 tumor spheres with indocyanine green (ICG) under 800nm irradiation. However, at 1K laser PRF, it takes approximately 20 minutes to obtain a full sample volume of 160 × 160 × 150 μm3 . To increase the imaging rate, we propose a random non-uniform sparse sampling mechanism to achieve fast sparse photoacoustic data acquisition. The image recovery process is formulated as a low-rank matrix recovery (LRMR) based on compressed sensing (CS) theory. We show that it could be stably recovered via nuclear-norm minimization optimization problem to maintain image quality from a significantly fewer measurement. In this study, we use the dual-wavelength OR-PAM with CS to visualize T cell trafficking in a 3D culture system with higher temporal resolution. Data acquisition time is reduced by 40% in such sample volume where sampling density is 0.5. The imaging system reveals the potential to understand the dynamic cellular process for preclinical screening of anti-cancer drugs.

  19. Ruptured Retinal Arterial Macroaneurysm Secondary to Toxoplasmic Kyrieleis Arteriolitis: A Case Report

    Directory of Open Access Journals (Sweden)

    Natalie Huang

    2017-07-01

    Full Text Available Purpose: The aim of this report was to describe multimodal ocular imaging findings in a patient who presented with a ruptured retinal arterial macroaneurysm (RAM associated with toxoplasmic Kyrieleis arteriolitis. Methods: We report the case of a 64-year-old man with a history of systemic hypertension and dense amblyopia of the left eye who presented with decreased vision and new floaters in the left eye. Color fundus photography, spectral-domain optical coherence tomography, fluorescein angiography, and indocyanine green angiography were used as diagnostic imaging tools. Results: No signs of hypertensive retinopathy were noted in the right eye. Multiple chorioretinal scars characteristic of previous toxoplasmosis were revealed in the left eye, with one covering most of the macula. Periarterial plaques or Kyrieleis arteriolitis were observed in retinal arteries surrounding the toxoplasmic retinal scars. Multiple RAMs were observed in these vessels, one of which was acutely ruptured. A perivenular plaque associated with a chronic branch retinal vein occlusion (BRVO was noted along the same arcade at the arteriovenous crossing. Conclusion: RAM formation and BRVO can present as possible long-term complications of toxoplasmic Kyrieleis arteriolitis. This is the first reported case demonstrating an association between toxoplasmic Kyrieleis arteriolitis and RAM formation.

  20. Lateral supraorbital approach to ipsilateral PCA-P1 and ICA-PCoA aneurysms.

    Science.gov (United States)

    Goehre, Felix; Jahromi, Behnam Rezai; Elsharkawy, Ahmed; Lehto, Hanna; Shekhtman, Oleg; Andrade-Barazarte, Hugo; Munoz, Francisco; Hijazy, Ferzat; Makhkamov, Makhkam; Hernesniemi, Juha

    2015-01-01

    Aneurysms of the posterior cerebral artery (PCA) are rare and often associated with anterior circulation aneurysms. The lateral supraorbital approach allows for a very fast and safe approach to the ipsilateral lesions Circle of Willis. A technical note on the successful clip occlusion of two aneurysms in the anterior and posterior Circle of Willis via this less invasive approach has not been published before. The objective of this technical note is to describe the simultaneous microsurgical clip occlusion of an ipsilateral PCA-P1 and an internal carotid artery - posterior communicating artery (ICA-PCoA) aneurysm via the lateral supraorbital approach. The authors present a technical report of successful clip occlusions of ipsilateral located PCA-P1 and ICA-PCoA aneurysms. A 59-year-old female patient was diagnosed with a PCA-P1 and an ipsilateral ICA-PCoA aneurysm by computed tomography angiography (CTA) after an ischemic stroke secondary to a contralateral ICA dissection. The patient underwent microsurgical clipping after a lateral supraorbital craniotomy. The intraoperative indocyanine green (ICG) videoangiography and the postoperative CTA showed a complete occlusion of both aneurysms; the parent vessels (ICA and PCA) were patent. The patient presents postoperative no new neurologic deficit. The lateral supraorbital approach is suitable for the simultaneous microsurgical treatment of proximal anterior circulation and ipsilateral proximal PCA aneurysms. Compared to endovascular treatment, direct visual control of brainstem perforators is possible.

  1. How I do it: assessment of hepatic functional reserve for indication of hepatic resection.

    Science.gov (United States)

    Lee, Sung-Gyu; Hwang, Shin

    2005-01-01

    Liver resection of up to 75% of the total liver volume (TLV) has been regarded as safe in normal livers, but this concept was challenged by the results of living donor hepatectomies. In normal livers or livers with resolved jaundice, hepatectomy of 65% of TLV may be safe, except for patients with an indocyanine green retention rate at 15 min (ICG R15) of over 15%, excessive hepatic steatosis, and age of over 70 years. However, the permissible extent of hepatectomy has been much restricted in cirrhotic livers because most post-hepatectomy liver failure (PHLF) has occurred in cirrhotic livers. Our routine protocols for the assessment of functional hepatic reserve (FHR) include biochemical liver function tests, ICG R15, Doppler ultrasonography, and triphasic liver computed tomogram (CT) with volumetry. Blood cell count and gastroesophageal endoscopic findings are taken into consideration for cirrhotic livers, as well as age, diabetes, cardiopulmonary function, and general performance. Preoperative portal vein embolization has been used for safe hepatectomy even in cirrhotic livers. We think that any cirrhotic liver showing optimal FHR should have a remnant liver of 40% of TLV to prevent PHLF. ICG R15 and triphasic CT with volumetry have been the most useful methods for assessment of FHR and determination of hepatectomy extent in our institution.

  2. Sutureless liver repair and hemorrhage control using laser-mediated fusion of human albumin as a solder.

    Science.gov (United States)

    Wadia, Y; Xie, H; Kajitani, M

    2001-07-01

    Major liver trauma has a high mortality because of immediate exsanguination and a delayed morbidity from septicemia, peritonitis, biliary fistulae, and delayed secondary hemorrhage. We evaluated laser soldering using liquid albumin for welding liver injuries. Fourteen lacerations (6 x 2 cm) and 13 nonanatomic resection injuries (raw surface, 8 x 2 cm) were repaired. An 805-nm laser was used to weld 53% liquid albumin-indocyanine green solder to the liver surface, reinforcing it by welding a free autologous omental scaffold. The animals were heparinized and hepatic inflow occlusion was used for vascular control. For both laceration and resection injuries, 16 soldering repairs were evaluated acutely at 3 hours. Eleven animals were evaluated chronically, two at 2 weeks and nine at 4 weeks. All 27 laser mediated-liver repairs had minimal blood loss compared with the suture controls. No dehiscence, hemorrhage, or bile leakage was seen in any of the laser repairs after 3 hours. All 11 chronic repairs healed without complication. This modality effectively seals the liver surface, joins lacerations with minimal thermal injury, and works independently of the patient's coagulation status.

  3. Investigation on fibrous collagen modifications during corneal laser welding by second harmonic generation microscopy

    Science.gov (United States)

    Matteini, Paolo; Ratto, Fulvio; Rossi, Francesca; Cicchi, Riccardo; Stringari, Chiara; Kapsokalyvas, Dimitrios; Pavone, Francesco S.; Pini, Roberto

    2009-02-01

    The structural modifications in the collagen lattice of corneal stroma induced by near-infrared laser welding were investigated with second-harmonic generation (SHG) imaging. The corneal laser welding procedure is performed by staining the wound edges with a saturated water solution of Indocyanine Green (ICG) followed by irradiation with a 810 nm diode laser operated in continuous (CWLW: continuous wave laser welding) or pulsed (PLW: pulsed laser welding) mode. Both these procedures can provide closure of corneal wounds by inducing different structural modifications in the extracellular matrix. SHG imaging of native corneal stroma revealed collagen bundles composed of many regularly aligned collagen fibrils. After CWLW the regular lamellar arrangement was lost; collagen bundles appeared densely packed with an increasing disordered arrangement toward the welded cut. The weld was characterized by a loss of details; nevertheless, the observation of the second harmonic signal at this site indicated the lack of collagen denaturation. By contrast, PLW mode produced welding spots at the interface between donor and recipient corneal layers, which were characterized by a severe loss of the SHG signal, suggesting the occurrence of a complete collagen denaturation. SHG imaging appeared to be a powerful tool for visualizing the supramolecular morphological modifications in the collagen matrix after laser welding.

  4. An “All-laser” Endothelial Transplant

    Science.gov (United States)

    Rossi, Francesca; Canovetti, Annalisa; Malandrini, Alex; Lenzetti, Ivo; Pini, Roberto; Menabuoni, Luca

    2015-01-01

    The “all laser” assisted endothelial keratoplasty is a procedure that is performed with a femtosecond laser used to cut the donor tissue at an intended depth, and a near infrared diode laser to weld the corneal tissue. The proposed technique enables to reach the three main goals in endothelial keratoplasty: a precise control in the thickness of the donor tissue; its easy insertion in the recipient bed and a reduced risk of donor lenticule dislocation. The donor cornea thickness is measured in the surgery room with optical coherence tomography (OCT), in order to correctly design the donor tissue dimensions. A femtosecond laser is used to cut the donor cornea. The recipient eye is prepared by manual stripping of the descemetic membrane. The donor endothelium is inserted into a Busin-injector, the peripheral inner side is stained with a proper chromophore (a water solution of Indocyanine Green) and then it is pulled in the anterior chamber. The transplanted tissue is placed in the final and correct location and then diode laser welding is induced from outside the eyeball. The procedure has been performed on more than 15 patients evidencing an improvement in surgery performances, with a good recovery of visual acuity and a reduced donor lenticule dislocation event. PMID:26167711

  5. Electrophoretic mobility patterns of collagen following laser welding

    Science.gov (United States)

    Bass, Lawrence S.; Moazami, Nader; Pocsidio, Joanne O.; Oz, Mehmet C.; LoGerfo, Paul; Treat, Michael R.

    1991-06-01

    Clinical application of laser vascular anastomosis in inhibited by a lack of understanding of its mechanism. Whether tissue fusion results from covalent or non-covalent bonding of collagen and other structural proteins is unknown. We compared electrophoretic mobility of collagen in laser treated and untreated specimens of rat tail tendon (>90% type I collagen) and rabbit aorta. Welding was performed, using tissue shrinkage as the clinical endpoint, using the 808 nm diode laser (power density 14 watts/cm2) and topical indocyanine green dye (max absorption 805 nm). Collagen was extracted with 8 M urea (denaturing), 0.5 M acetic acid (non-denaturing) and acetic acid/pepsin (cleaves non- helical protein). Mobility patterns on gel electrophoresis (SDS-PAGE) after urea or acetic acid extraction were identical in the lasered and control tendon and vessel (confirmed by optical densitometry), revealing no evidence of formation of novel covalent bonds. Alpha and beta band intensity was diminished in pepsin incubated lasered specimens compared with controls (optical density ratio 0.00 +/- 9 tendon, 0.65 +/- 0.12 aorta), indicating the presence of denatured collagen. With the laser parameters used, collagen is denatured without formation of covalent bonds, suggesting that non-covalent interaction between denatured collagen molecules may be responsible for the weld. Based on this mechanism, welding parameters can be chosen which produce collagen denaturation without cell death.

  6. Intraosseous repair of the inferior alveolar nerve in rats: an experimental model.

    Science.gov (United States)

    Curtis, N J; Trickett, R I; Owen, E; Lanzetta, M

    1998-08-01

    A reliable method of exposure of the inferior alveolar nerve in Wistar rats has been developed, to allow intraosseous repair with two microsurgical techniques under halothane inhalational anaesthesia. The microsuturing technique involves anastomosis with 10-0 nylon sutures; a laser-weld technique uses an albumin-based solder containing indocyanine green, plus an infrared (810 nm wavelength) diode laser Seven animals had left inferior alveolar nerve repairs performed with the microsuture and laser-weld techniques. Controls were provided by unoperated nerves in the repaired cases. Histochemical analysis was performed utilizing neuron counts and horseradish peroxidase tracer (HRP) uptake in the mandibular division of the trigeminal ganglion, following sacrifice and staining of frozen sections with cresyl violet and diaminobenzidene. The results of this analysis showed similar mean neuron counts and mean HRP uptake by neurons for the unoperated controls and both microsuture and laser-weld groups. This new technique of intraosseous exposure of the inferior alveolar nerve in rats is described. It allows reliable and reproducible microsurgical repairs using both microsuture and laser-weld techniques.

  7. Dye-enhanced laser welding for skin closure.

    Science.gov (United States)

    DeCoste, S D; Farinelli, W; Flotte, T; Anderson, R R

    1992-01-01

    The use of a laser to weld tissue in combination with a topical photosensitizing dye permits selective delivery of energy to the target tissue. A combination of indocyanine green (IG), absorption peak 780 nm, and the near-infrared (IR) alexandrite laser was studied with albino guinea pig skin. IG was shown to bind to the outer 25 microns of guinea pig dermis and appeared to be bound to collagen. The optical transmittance of full-thickness guinea pig skin in the near IR was 40% indicating that the alexandrite laser should provide adequate tissue penetration. Laser "welding" of skin in vivo was achieved at various concentrations of IG from 0.03 to 3 mg/cc using the alexandrite at 780 nm, 250-microseconds pulse duration, 8 Hz, and a 4-mm spot size. A spectrum of welds was obtained from 1- to 20-W/cm2 average irradiance. Weak welds occurred with no thermal damage obtained at lower irradiances: stronger welds with thermal damage confined to the weld site occurred at higher irradiances. At still higher irradiances, local vaporization occurred with failure to "weld." Thus, there was an optimal range of irradiances for "welding," which varied inversely with dye concentration. Histology confirmed the thermal damage results that were evident clinically. IG dye-enhanced laser welding is possible in skin and with further optimization may have practical application.

  8. Tissue soldering with biodegradable polymer films: in-vitro investigation of hydration effects on weld strength

    Science.gov (United States)

    Sorg, Brian S.; Welch, Ashley J.

    2001-05-01

    Previous work demonstrated increased breaking strengths of tissue repaired with liquid albumin solder reinforced with a biodegradable polymer film compared to unreinforced control specimens. It was hypothesized that the breaking strength increase was due to reinforcement of the liquid solder cohesive strength. Immersion in a moist environment can decrease the adhesion of solder to tissue and negate any strength benefits gained from reinforcement. The purpose of this study was to determine if hydrated specimens repaired with reinforced solder would still be stronger than unreinforced controls. A 50%(w/v) bovine serum albumin solder with 0.5 mg/mL Indocyanine Green dye was used to repair an incision in bovine aorta. The solder was coagulated with 806-nm diode laser light. A poly(DL-lactic- co-glycolic acid) film was used to reinforce the solder (the controls had no reinforcement). The repaired tissues were immersed in phosphate buffered saline for time periods of 1 and 2 days. The breaking strengths of all of the hydrated specimens decreased compared to the acute breaking strengths. However, the reinforced specimens still had larger breaking strengths than the unreinforced controls. These results indicate that reinforcement of a liquid albumin solder may have the potential to improve the breaking strength in a clinical setting.

  9. Changes in type I collagen following laser welding.

    Science.gov (United States)

    Bass, L S; Moazami, N; Pocsidio, J; Oz, M C; LoGerfo, P; Treat, M R

    1992-01-01

    Selection of ideal laser parameters for tissue welding is inhibited by poor understanding of the mechanism. We investigated structural changes in collagen molecules extracted from rat tail tendon (> 90% type I collagen) after tissue welding using an 808 nm diode laser and indocyanine green dye applied to the weld site. Mobility patterns on SDS-PAGE were identical in the lasered and untreated tendon extracts with urea or acetic acid. Pepsin incubation after acetic acid extraction revealed a reduction of collagen alpha and beta bands in lasered compared with untreated specimens. Circular dichroism studies of rat tail tendon showed absence of helical structure in collagen from lasered tendon. No evidence for covalent bonding was present in laser-treated tissues. Collagen molecules are denatured by the laser wavelength and parameters used in this study. No significant amount of helical structure is regenerated on cooling. We conclude that non-covalent interactions between denatured collagen molecules may be responsible for the creation of tissue welding.

  10. Liver repair and hemorrhage control by using laser soldering of liquid albumin in a porcine model.

    Science.gov (United States)

    Wadia, Y; Xie, H; Kajitani, M

    2000-01-01

    We evaluated laser soldering by using liquid albumin for welding liver injuries. Major liver trauma has a high mortality because of immediate exsanguination and a delayed morbidity from septicemia, peritonitis, biliary fistulae, and delayed secondary hemorrhage. Eight laceration (6 x 2 cm) and eight nonanatomic resection injuries (raw surface, 6 x 2 cm) were repaired. An 805-nm laser was used to weld 50% liquid albumin-indocyanine green solder to the liver surface, reinforcing it with a free autologous omental scaffold. The animals were heparinized and hepatic inflow occlusion was used for vascular control. All 16 soldering repairs were evaluated at 3 hours. All 16 laser mediated liver repairs had minimal blood loss as compared with the suture controls. No dehiscence, hemorrhage, or bile leakage was seen in any of the laser repairs after 3 hours. Laser fusion repair of the liver is a reliable technique to gain hemostasis on the raw surface as well as weld lacerations. Copyright 2000 Wiley-Liss, Inc.

  11. Experimental and computational laser tissue welding using a protein patch.

    Science.gov (United States)

    Small, W; Heredia, N J; Maitland, D J; Eder, D C; Celliers, P M; Da Silva, L B; London, R A; Matthews, D L

    1998-01-01

    An in vitro study of laser tissue welding mediated with a dye-enhanced protein patch was conducted. Fresh sections of porcine aorta were used for the experiments. Arteriotomies were treated using an indocyanine green dye-enhanced collagen patch activated by an 805-nm continuous-wave fiber-delivered diode laser. Temperature histories of the surface of the weld site were obtained using a hollow glass optical fiber-based two-color infrared thermometer. The experimental effort was complemented by simulations with the LATIS (LAser-TISsue) computer code, which uses coupled Monte Carlo, thermal transport, and mass transport models. Comparison of simulated and experimental thermal data indicated that evaporative cooling clamped the surface temperature of the weld site below 100 °C. For fluences of approximately 200 J/cm2, peak surface temperatures averaged 74°C and acute burst strengths consistently exceeded 0.14×106 dyn/cm (hoop tension). The combination of experimental and simulation results showed that the inclusion of water transport and evaporative losses in the computer code has a significant impact on the thermal distributions and hydration levels throughout the tissue volume. The solid-matrix protein patch provided a means of controllable energy delivery and yielded consistently strong welds. © 1998 Society of Photo-Optical Instrumentation Engineers.

  12. Preliminary results of laser tissue welding in extravesical reimplantation of the ureters.

    Science.gov (United States)

    Kirsch, A J; Dean, G E; Oz, M C; Libutti, S K; Treat, M R; Nowygrod, R; Hensle, T W

    1994-02-01

    One exciting potential use of laparoscopic technology is the extravesical reimplantation of the ureters. We have assessed the efficacy of laser-activated fibrinogen solder to close vesical muscle flaps over submucosal ureters (Lich-Gregoir technique) in a canine model. Four dogs were subjected to unilateral flap closures via a protein solder (indocyanine green and fibrinogen) applied to the bladder serosa and exposed to 808 nm. continuous wave diode laser energy. Contralateral reimplantation was performed using 4-zero vicryl muscle flap closures (controls). At 7, 14 and 28 days postoperatively, intravenous pyelograms confirmed bilateral ureteral patency. At intravesical pressures above 100 cm. H2O, there was no evidence of wound disruption in either group. Nondisrupted wound closures were sectioned and strained until ultimate breakage to determine tensile strength. At each study interval the laser-welded closures withstood greater stress than the controls. Although these data represent single tissue samples and are not amenable to statistical analysis, laser-welded closures appeared to be stronger at each study interval. In conclusion, laser-welded vesical wound closures appear at least as strong as suture closures in the canine model.

  13. Optimal dye concentration and irradiance for laser-assisted vascular anastomosis.

    Science.gov (United States)

    Ren, Zhen; Xie, Hua; Lagerquist, Kathryn A; Burke, Allen; Prahl, Scott; Gregory, Kenton W; Furnary, Anthony P

    2004-04-01

    This investigation was done in order to find optimal indocyanine green (ICG) concentration and energy irradiance in laser vascular welding. Many studies have shown that laser tissue welding with albumin solder/ICG may be an effective technique in surgical reconstruction. However, there are few reports regarding optimal laser settings and concentrations of ICG within the albumin solder in laser-assisted vascular anastomosis. Porcine carotid artery strips (n = 120) were welded in end-to-end by diode laser with 50% albumin solder of 0.01, 0.1, and 1.0 mM ICG at irradiance of 27.7, 56.7, and 76.9 W/cm(2), respectively. Temperature was measured by inserting thermocouples outside and inside the vessel. Tensile strength and histology were studied. Temperature and strength of the anastomosis significantly decreased (all p < 0.05) with increasing ICG concentration at 56.7 W/cm(2). Histological study showed minimal thermal injury limited to adventitia and no appreciable difference between all groups. ICG concentration within solder is the most important factor affecting both vascular temperature and tensile strength. The optimal balance between strength and minimal thermal injury may be achieved primarily at 56.7 W/cm(2) and 0.01 mM ICG.

  14. Laser-assisted fibrinogen bonding of umbilical vein grafts.

    Science.gov (United States)

    Oz, M C; Williams, M R; Souza, J E; Dardik, H; Treat, M R; Bass, L S; Nowygrod, R

    1993-06-01

    Despite success with autologous tissue welding, laser welding of synthetic vascular prostheses has not been possible. The graft material appears inert and fails to allow the collagen breakdown and electrostatic bonding that results in tissue welding. To develop a laser welding system for graft material, we repaired glutaraldehyde-tanned human umbilical cord vein graft incisions using laser-assisted fibrinogen bonding (LAFB) technology. Modified umbilical vein graft was incised transversely (1.2 cm). Incisions were repaired using sutures, laser energy alone, or LAFB. For LAFB, indocyanine green dye was mixed with human fibrinogen and the compound applied with forceps onto the weld site prior to exposure to 808 nm diode laser energy (power density 4.8 W/cm 2). Bursting pressures for sutured repairs (126.6 +/- 23.4 mm Hg) were similar to LAFB anastomoses (111.6 +/- 55.0 mm Hg). No evidence of collateral thermal injury to the graft material was noted. In vivo evaluation of umbilical graft bonding with canine arteries demonstrates that LAFB can reliably reinforce sutured anastomoses. The described system for bonding graft material with laser exposed fibrinogen may allow creation or reinforcement of vascular anastomoses in procedures where use of autologous tissue is not feasible.

  15. An "All-laser" Endothelial Transplant.

    Science.gov (United States)

    Rossi, Francesca; Canovetti, Annalisa; Malandrini, Alex; Lenzetti, Ivo; Pini, Roberto; Menabuoni, Luca

    2015-07-06

    The "all laser" assisted endothelial keratoplasty is a procedure that is performed with a femtosecond laser used to cut the donor tissue at an intended depth, and a near infrared diode laser to weld the corneal tissue. The proposed technique enables to reach the three main goals in endothelial keratoplasty: a precise control in the thickness of the donor tissue; its easy insertion in the recipient bed and a reduced risk of donor lenticule dislocation. The donor cornea thickness is measured in the surgery room with optical coherence tomography (OCT), in order to correctly design the donor tissue dimensions. A femtosecond laser is used to cut the donor cornea. The recipient eye is prepared by manual stripping of the descemetic membrane. The donor endothelium is inserted into a Busin-injector, the peripheral inner side is stained with a proper chromophore (a water solution of Indocyanine Green) and then it is pulled in the anterior chamber. The transplanted tissue is placed in the final and correct location and then diode laser welding is induced from outside the eyeball. The procedure has been performed on more than 15 patients evidencing an improvement in surgery performances, with a good recovery of visual acuity and a reduced donor lenticule dislocation event.

  16. Effect of laser wavelength and protein solder concentration on acute tissue repair using laser welding: initial results in a canine ureter model.

    Science.gov (United States)

    Wright, E J; Poppas, D P

    1997-01-01

    Successful tissue approximation can be performed using low power laser energy combined with human albumin solder. In vitro studies were undertaken to investigate the acute repair strengths achieved using different laser wavelengths. Furthermore, we evaluated the change in repair strength with that resulted from changes in protein solder concentration. Intraluminal bursting pressure following ureterotomy repair was measured for the following laser wavelengths: 532, 808, 1,320, 2,100, and 10,600 nm. The tissue absorption characteristics of the 808-nm diode and the KTP-532-nm lasers required the addition of the exogenous chromophores indocyanine green and fluorescein, respectively. A 40% human albumin solder was incorporated in the repair of a 1.0-cm longitudinal defect in the canine ureter. Following determination of an optimal welding wavelength, human albumin solder of varying concentrations (25%, 38%, 45%, and 50%) were prepared and tested. The 1,320-nm YAG laser achieved the highest acute bursting pressure and was the most effective in this model. Of the concentrations of albumin tested, 50% human albumin yielded the greatest bursting pressures. We conclude that of the laser wavelengths evaluated, the 1,320-nm YAG achieves the strongest tissue weld in the acute ex vivo dog ureter model. In addition, when this laser system is used, the acute strength of a photothermal weld appears to be directly proportional to the concentration of human albumin solder in the range of 25 to 50%.

  17. Experimental study on the healing process following laser welding of the cornea.

    Science.gov (United States)

    Rossi, Francesca; Pini, Roberto; Menabuoni, Luca; Mencucci, Rita; Menchini, Ugo; Ambrosini, Stefano; Vannelli, Gabriella

    2005-01-01

    An experimental study evaluating the application of laser welding of the cornea and the subsequent healing process is presented. The welding of corneal wounds is achieved after staining the cut walls with a solution of the chromophore indocyanine green, and irradiating them with a diode laser (810 nm) operating at low power (60 to 90 mW). The result is a localized heating of the cut, inducing controlled welding of the stromal collagen. In order to optimize this technique and to study the healing process, experimental tests, simulating cataract surgery and penetrating keratoplasty, were performed on rabbits: conventional and laser-induced suturing of corneal wounds were thus compared. A follow-up study 7 to 90 days after surgery was carried out by means of objective and histological examinations, in order to optimize the welding technique and to investigate the subsequent healing process. The analyses of the laser-welded corneas evidenced a faster and more effective restoration of the architecture of the stroma. No thermal damage of the welded stroma was detected, nor were there foreign body reactions or other inflammatory processes. Copyright 2005 Society of Photo-Optical Instrumentation Engineers.

  18. Comparative in vitro study of tissue welding using a 808 nm diode laser and a Ho:YAG laser.

    Science.gov (United States)

    Ott, B; Züger, B J; Erni, D; Banic, A; Schaffner, T; Weber, H P; Frenz, M

    2001-01-01

    In vitro porcine arteries and veins have been welded end-to-end using either a 808 nm diode laser combined with an indocyanine green enhanced albumin solder, or with a continuous-wave (cw) Ho:YAG laser without biological solder. The vascular stumps were approached to each other over a coronary dilatation catheter in order to obtain a precise alignment and good coaptation. Standard histology revealed for both welding techniques lateral tissue damage between 2 and 3 mm caused by laser-induced heat. Good solder attachment to the tissue was observed by the use of a scanning electron microscope. The vessels soldered with the 808 nm diode laser using albumin solder showed considerably higher tensile strength (1 N compared to 0.3 N) than vessels welded exclusively by Ho:YAG laser radiation. In contrast, leaking pressure (350 +/- 200 mmHg) and bursting pressure (457 +/- 200 mmHg) were found to be independent of the welding technique used. This study demonstrates that fast (total welding time about 2-5 min), stable and tight microvascular anastomosis can be achieved with the use of a dye-enhanced albumin laser soldering technique and an ancillary coronary dilatation catheter.

  19. Laser tissue welding in genitourinary reconstructive surgery: assessment of optimal suture materials.

    Science.gov (United States)

    Poppas, D P; Klioze, S D; Uzzo, R G; Schlossberg, S M

    1995-02-01

    Laser tissue welding in genitourinary reconstructive surgery has been shown in animal models to decrease operative time, improve healing, and decrease postoperative fistula formation when compared with conventional suture controls. Although the absence of suture material is the ultimate goal, this has not been shown to be practical with current technology for larger repairs. Therefore, suture-assisted laser tissue welding will likely be performed. This study sought to determine the optimal suture to be used during laser welding. The integrity of various organic and synthetic sutures exposed to laser irradiation were analyzed. Sutures studied included gut, clear Vicryl, clear polydioxanone suture (PDS), and violet PDS. Sutures were irradiated with a potassium titanyl phosphate (KTP)-532 laser or an 808-nm diode laser with and without the addition of a light-absorbing chromophore (fluorescein or indocyanine green, respectively). A remote temperature-sensing device obtained real-time surface temperatures during lasing. The average temperature, time, and total energy at break point were recorded. Overall, gut suture achieved significantly higher temperatures and withstood higher average energy delivery at break point with both the KTP-532 and the 808-nm diode lasers compared with all other groups (P welding appears to be between 60 degrees and 80 degrees C. Gut suture offers the greatest margin of error for KTP and 808-nm diode laser welding with or without the use of a chromophore.

  20. Laser-activated protein solder for peripheral nerve repair

    Science.gov (United States)

    Trickett, Rodney I.; Lauto, Antonio; Dawes, Judith M.; Owen, Earl R.

    1995-05-01

    A 100 micrometers core optical fiber-coupled 75 mW diode laser operating at a wavelength of 800 nm has been used in conjunction with a protein solder to stripe weld severed rat tibial nerves, reducing the long operating time required for microsurgical nerve repair. Welding is produced by selective laser denaturation of the albumin based solder which contains the dye indocyanine green. Operating time for laser soldering was 10 +/- 5 min. (n equals 20) compared to 23 +/- 9 min. (n equals 10) for microsuturing. The laser solder technique resulted in patent welds with a tensile strength of 15 +/- 5 g, while microsutured nerves had a tensile strength of 40 +/- 10 g. Histopathology of the laser soldered nerves, conducted immediately after surgery, displayed solder adhesion to the outer membrane with minimal damage to the inner axons of the nerves. An in vivo study is under way comparing laser solder repaired tibial nerves to conventional microsuture repair. At the time of submission 15 laser soldered nerves and 7 sutured nerves were characterized at 3 months and showed successful regeneration with compound muscle action potentials of 27 +/- 8 mV and 29 +/- 8 mW respectively. A faster, less damaging and long lasting laser based anastomotic technique is presented.

  1. The Effect of NIR Light and the Light-Activated Antimicrobial Agent on Wound Pathogenic Biofilms; Implication for Nonpharmacologic Chronic Wound Treatment

    DEFF Research Database (Denmark)

    Omar, Ghada Said Mohammed

    2015-01-01

    to the increase of lifestyle diseases, as diabetes, obesity, and cardiovascular diseases. The presence of bacterial biofilms is considered an important factor responsible for wounds chronicity. Therefore, this study investigates the efficacy of near-infrared (NIR) laser in vitro, in disrupting wound pathogenic...... biofilms. Metoder / Methods Biofilms of Staphylococcus aureus and Pseudomonas aeruginosa were grown in a 96-well microtiter plate for 18-22 h. The study included 4 arms: (a) control; (b) 200 µg/mL Indocyanin green (ICG) kept in the dark, (c) NIR laser alone; (d) NIR laser combined with 200 µg/mL. ICG....... The biofilms were exposed to different light doses from the 808 nm NIR laser at a fluence rate of 0.3 W/cm2. Crystal violate assay and viable count were used to detect the effect. (Foreløbige) resultater / (Preliminary) Results A light dose of 90 J/cm2 killed approximately 99.9% of P. aeruginosa bacterial...

  2. Hyaluronan-Based Nanohydrogels as Effective Carriers for Transdermal Delivery of Lipophilic Agents: Towards Transdermal Drug Administration in Neurological Disorders

    Directory of Open Access Journals (Sweden)

    Seong Uk Son

    2017-12-01

    Full Text Available We suggest a convenient nanoemulsion fabrication method to create hyaluronan (HA-based nanohydrogels for effective transdermal delivery. First, hyaluronan-conjugated dodecylamine (HA–Do HA-based polymers to load the lipophilic agents were synthesized with hyaluronan (HA and dodecylamine (Do by varying the substitution ratio of Do to HA. The synthetic yield of HA–Do was more than 80% (HA–Do (A: 82.7 ± 4.7%, HA–Do (B: 87.1 ± 3.9% and HA–Do (C: 81.4 ± 4.5%. Subsequently, nanohydrogels were fabricated using the nanoemulsion method. Indocyanine green (ICG simultaneously self-assembled with HA–Do, and the size depended on the substitution ratio of Do in HA–Do (nanohydrogel (A: 118.0 ± 2.2 nm, nanohydrogel (B: 121.9 ± 11.4 nm, and nanohydrogel (C: 142.2 ± 3.8 nm. The nanohydrogels were delivered into cells, and had excellent biocompatibility. Especially, nanohydrogel (A could deliver and permeate ICG into the deep skin layer, the dermis. This suggests that nanohydrogels can be potent transdermal delivery systems.

  3. Splanchnic blood flow and hepatic glucose production in exercising humans

    DEFF Research Database (Denmark)

    Bergeron, R; Kjaer, M; Simonsen, L

    2001-01-01

    The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin-converti......The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin......-converting enzyme (ACE) blockade] or without (control) administration of the ACE inhibitor enalapril (10 mg iv). Splanchnic blood flow was estimated by indocyanine green, and splanchnic substrate exchange was determined by the arteriohepatic venous difference. Exercise led to an approximately 20-fold increase (P ...-blockade group vs. the control group, hormones, metabolites, VO(2), and RER followed the same pattern of changes in ACE-blockade and control groups during exercise. Splanchnic blood flow (at rest: 1.67 +/- 0.12, ACE blockade; 1.59 +/- 0.18 l/min, control) decreased during moderate exercise (0.78 +/- 0.07, ACE...

  4. Lymphatic imaging in unsedated infants and children

    Science.gov (United States)

    Rasmussen, John C.; Balaguru, Duraisamy; Douglas, William I.; Breinholt, John P.; Greives, Matthew R.; Aldrich, Melissa B.; Sevick-Muraca, Eva M.

    2017-02-01

    Primary lymphedema and lymphatic malformations in the pediatric population remains poorly diagnosed and misunderstood due to a lack of information on the underlying anatomy and function of the lymphatic system. Diagnostics for the lymphatic vasculature are limited, consisting of lymphoscintigraphy or invasive lymphangiography, both of which require sedation that can restrict use in infants and children. As a result, therapeutic protocols for pediatric patients with lymphatic disorders remain sparse and with little evidence to support them. Because near-infrared fluorescence (NIRF) imaging enables image acquisition on the order of tenths of seconds with trace administration of fluorescent dye, sedation is not necessary. The lack of harmful radiation and radioactive contrast agents further facilitates imaging. Herein we summarize our experiences in imaging infants and children who are suspected to have disorders of the lymphatic vascular system using indocyanine green (ICG) and who have developed chylothorax following surgery for congenital heart defects. The results show both anatomical as well as functional lymphatic deficits in children with congenital disease. In the future, NIRF lymphatic imaging could provide new opportunities to tailor effective therapies and monitor responses. The opportunity to use expand NIRF imaging for pediatric diagnostics beyond the lymphatic vasculature is also afforded by the rapid acquisition following trace administration of NIRF contrast agent.

  5. Virus-resembling nano-structures for near infrared fluorescence imaging of ovarian cancer HER2 receptors

    Science.gov (United States)

    Guerrero, Yadir A.; Bahmani, Baharak; Singh, Sheela P.; Vullev, Valentine I.; Kundra, Vikas; Anvari, Bahman

    2015-10-01

    Ovarian cancer remains the dominant cause of death due to malignancies of the female reproductive system. The capability to identify and remove all tumors during intraoperative procedures may ultimately reduce cancer recurrence, and lead to increased patient survival. The objective of this study is to investigate the effectiveness of an optical nano-structured system for targeted near infrared (NIR) imaging of ovarian cancer cells that over-express the human epidermal growth factor receptor 2 (HER2), an important biomarker associated with ovarian cancer. The nano-structured system is comprised of genome-depleted plant-infecting brome mosaic virus doped with NIR chromophore, indocyanine green, and functionalized at the surface by covalent attachment of monoclonal antibodies against the HER2 receptor. We use absorption and fluorescence spectroscopy, and dynamic light scattering to characterize the physical properties of the constructs. Using fluorescence imaging and flow cytometry, we demonstrate the effectiveness of these nano-structures for targeted NIR imaging of HER2 receptors in vitro. These functionalized nano-materials may provide a platform for NIR imaging of ovarian cancer.

  6. Virus-resembling nano-structures for near infrared fluorescence imaging of ovarian cancer HER2 receptors

    International Nuclear Information System (INIS)

    Guerrero, Yadir A; Bahmani, Baharak; Vullev, Valentine I; Anvari, Bahman; Singh, Sheela P; Kundra, Vikas

    2015-01-01

    Ovarian cancer remains the dominant cause of death due to malignancies of the female reproductive system. The capability to identify and remove all tumors during intraoperative procedures may ultimately reduce cancer recurrence, and lead to increased patient survival. The objective of this study is to investigate the effectiveness of an optical nano-structured system for targeted near infrared (NIR) imaging of ovarian cancer cells that over-express the human epidermal growth factor receptor 2 (HER2), an important biomarker associated with ovarian cancer. The nano-structured system is comprised of genome-depleted plant-infecting brome mosaic virus doped with NIR chromophore, indocyanine green, and functionalized at the surface by covalent attachment of monoclonal antibodies against the HER2 receptor. We use absorption and fluorescence spectroscopy, and dynamic light scattering to characterize the physical properties of the constructs. Using fluorescence imaging and flow cytometry, we demonstrate the effectiveness of these nano-structures for targeted NIR imaging of HER2 receptors in vitro. These functionalized nano-materials may provide a platform for NIR imaging of ovarian cancer. (paper)

  7. Unusual optical coherence tomography and fundus autofluorescence findings of eclipse retinopathy

    Directory of Open Access Journals (Sweden)

    Kun-Hsien Li

    2012-01-01

    Full Text Available A 63-year-old female patient complained of dimness in the central field of vision in the left eye after viewing an annular partial eclipse without adequate eye protection on 22 July 2009. Fundoscopy showed a wrinkled macular surface. Fundus autofluorescence study revealed well-demarcated hyperautofluorescence at the fovea. Optical coherence tomography demonstrated tiny intraretinal cysts. Fluorescein angiography and indocyanine green angiography were unremarkable. Epimacular membrane developed in the following month with deteriorated vision. Vitrectomy, epiretinal membrane and internal limiting membrane peeling were performed. Vision was restored to 20/20 after the operation. Direct sun-gazing may damage the retinal structures resulting in macular inflammation and increased focal metabolism, which explains the hyperautofluorescence. It may also induce epimacular membrane. Fundus autofluorescence might represent a useful technique to detect subtle solar-induced injuries of the retina. The visual prognosis is favorable but prevention remains the mainstay of treatment. Public health education is mandatory in reducing visual morbidity.

  8. Valsalva-Related Subretinal Hemorrhage as a Presenting Symptom of Polypoidal Choroidal Vasculopathy

    Directory of Open Access Journals (Sweden)

    Yousif Subhi

    2017-01-01

    Full Text Available Purpose. To describe a case of Valsalva-related subretinal hemorrhage as a presenting symptom of polypoidal choroidal vasculopathy (PCV. The patient refrained from treatment against our best advice, and thus this is also a rare case of the natural course of an untreated PCV. Methods. Case report. Results. A 66-year-old female with a respiratory infection coughed intensely until exhaustion, after which she developed visual symptoms on the right eye. Primary care ophthalmologist examined the patient on the same day of the onset of symptoms and referred her to our tertiary medical retinal service for detailed retinal diagnosis including fluorescein and indocyanine green angiography. The right eye had a large subretinal hemorrhage and pigment epithelium detachment in the lower temporal arcade with foveal involvement. Against our best advice, the patient refused treatment. In the following 9 months, the BCVA decreased from 68 to 55 ETDRS letters, the subretinal hemorrhage almost regressed, pigment epithelium detachments persisted, and macular edema, intraretinal cysts, and subretinal fibrosis developed. Conclusions. Although classic Valsalva retinopathy with preretinal hemorrhage in most cases can be managed by careful observation and no treatment, this case demonstrates that Valsalva-related subretinal hemorrhage needs different attention and approach.

  9. New opportunities in endocrine ophthalmopathy diagnostics (review

    Directory of Open Access Journals (Sweden)

    Elizaveta S. Taskina

    2017-12-01

    Full Text Available Endocrine ophthalmopathy (EOP is a progressive autoimmune disease that affects soft retrobulbar tissues in thyroid gland diseases. The statistical data on this disease are presented. The review presents both generally accepted and alternative approaches to the diagnosis of EOP different stages. Detailed clinical symptoms, main severity and activity score classifications of EOP, the required list of physical and instrumental examinations are given. We described the diagnostic value of computed tomography, magnetic resonance imaging, optical coherence tomography, Heidelberg Retina Tomography, radioisotope studies, triplex scanning of the major vessels of the eye, the Doppler mapping method, indocyanine-green angiography, as well as the histological examination of soft retrobulbar tissues biopsy in EOP. Generally accepted diagnostic methods of EOP have their disadvantages. Therefore, nowadays the promising direction is immunological, biochemical and genetic studies of EOP activity markers. The peculiarity of these methods in EOP diagnosis is an accuracy, possibility of multiple measurements, few side effects and a relatively low cost. Further studies of key mechanisms of the development of edema, leukocyte infiltration with subsequent formation of fibrosis of extraocular muscles and retrobulbar fiber in EOP is of significance, which may improve diagnostics of clinical complicated cases and initial stages of the disease.

  10. Oral Administration and Detection of a Near-Infrared Molecular Imaging Agent in an Orthotopic Mouse Model for Breast Cancer Screening.

    Science.gov (United States)

    Bhatnagar, Sumit; Verma, Kirti Dhingra; Hu, Yongjun; Khera, Eshita; Priluck, Aaron; Smith, David E; Thurber, Greg M

    2018-05-07

    Molecular imaging is advantageous for screening diseases such as breast cancer by providing precise spatial information on disease-associated biomarkers, something neither blood tests nor anatomical imaging can achieve. However, the high cost and risks of ionizing radiation for several molecular imaging modalities have prevented a feasible and scalable approach for screening. Clinical studies have demonstrated the ability to detect breast tumors using nonspecific probes such as indocyanine green, but the lack of molecular information and required intravenous contrast agent does not provide a significant benefit over current noninvasive imaging techniques. Here we demonstrate that negatively charged sulfate groups, commonly used to improve solubility of near-infrared fluorophores, enable sufficient oral absorption and targeting of fluorescent molecular imaging agents for completely noninvasive detection of diseased tissue such as breast cancer. These functional groups improve the pharmacokinetic properties of affinity ligands to achieve targeting efficiencies compatible with clinical imaging devices using safe, nonionizing radiation (near-infrared light). Together, this enables development of a "disease screening pill" capable of oral absorption and systemic availability, target binding, background clearance, and imaging at clinically relevant depths for breast cancer screening. This approach should be adaptable to other molecular targets and diseases for use as a new class of screening agents.

  11. Evaluation of reserved hepatic function in patients with hepatobiliary tumor by {sup 99m}Tc-GSA. Effect of hyperbilirubinemia and usefulness of regional reserved hepatic functional imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jin Wu; Ishikawa, Nobuyoshi; Takeda, Tohoru; Sato, Motohiro; Todoroki, Takeshi; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Fukunaga, Kiyoshi; Okumura, Toshiyuki; Hatakeyama, Rokurou

    1996-02-01

    The evaluation of the reserved hepatic function was performed by {sup 99m}Tc-galactosyl serum albumin ({sup 99m}Tc-GSA) in 70 patients with hepatobiliary tumor. The dynamic study was performed to evaluate global reserved hepatic function following the intravenous bolus injection of {sup 99m}Tc-GSA, and the hepatic single photon emission computed tomography (SPECT) was obtained to assess the regional reserved hepatic function. The functional hepatic index (LHL{sub 15}) was derived from liver time-activity data, and it was compared with serum total-bilirubin level, serum albumin level and plasma disappearance rate of indocyanine green (ICG{sub 15}). In the patients with hepatocellular carcinoma, LHL{sub 15} value agreed well with ICG{sub 15} value, serum total-bilirubin level, and serum albumin level. Moderate or severe hepatic dysfunction was observed at 65.4% of these patients. In the patients with cholangiocellular carcinoma, a discrepancy of LHL{sub 15} value and ICG{sub 15} value was observed. Increment of the ICG{sub 15} value was correlated with that of the serum total-bilirubin level, whereas the correlation was not observed between the LHL{sub 15} value and the serum total-bilirubin level. These results indicate that {sup 99m}Tc-GSA scintigraphy can evaluate the reserved hepatic function without the embellishment of jaundice. This method is useful for assessing the global and regional reserved hepatic function. (author).

  12. [A case of ophthalmic artery occlusion following injection of hyaluronic acid into the glabellar area].

    Science.gov (United States)

    Nonomura, Sakiko; Oshitari, Toshiyuki; Miura, Gen; Chiba, Akihiro; Yamamoto, Shuichi

    2014-09-01

    We report a case of unilateral blindness due to ophthalmic artery occlusion following injection of hyaluronic acid into the glabellar area for facial soft-tissue augmentation. A 20-year old woman underwent injection of hyaluronic acid into the glabellar area at an aesthetic plastic clinic. Immediately after injection, she suffered nausea, pain, paralysis of limbs and visual loss in her right eye. Hyaluronidase was instanly injected into the same place, but these symptoms did not improve. She was transferred to our hospital's emergency department. At the first examination, she had no light perception in the right eye and her right pupil was dilated. The fundus examination revealed right central artery occlusion. No significant findings were detected in her head. Eye ball massage, hyperbaric oxygen therapy, and drip infusion of urokinase were conducted, but no improvement resulted. Fluorescein and indocyanine green angiography showed no filling of the right retinal and choroidal arteries. Electroretinogram was completely disappeared. Magnetic resonance angiography could not reveal the obstruction point of the ophthalmic artery. Ophthalmic artery occlusion was believed to have occured after injection of hyaluronic acid into the glabellar area.

  13. Laser welding and collagen crosslinks

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, K.M.; Last, J.A. [California Univ., Davis, CA (United States). Dept. of Medicine; Small, W. IV; Maitland, D.J.; Heredia, N.J.; Da Silva, L.B.; Matthews, D.L. [Lawrence Livermore National Lab., CA (United States)

    1997-02-20

    Strength and stability of laser-welded tissue may be influenced, in part, by effects of laser exposure on collagen crosslinking. We therefore studied effects of diode laser exposure (805 nm, 1-8 watts, 30 seconds) + indocyanine green dye (ICG) on calf tail tendon collagen crosslinks. Effect of ICG dye alone on crosslink content prior to laser exposure was investigated; unexpectedly, we found that ICG-treated tissue had significantly increased DHLNL and OHP, but not HLNL. Laser exposure after ICG application reduced elevated DHLNL and OHP crosslink content down to their native levels. The monohydroxylated crosslink HLNL was inversely correlated with laser output (p<0.01 by linear regression analysis). DHLNL content was highly correlated with content of its maturational product, OHP, suggesting that precursor-product relations are maintained. We conclude that: (1)ICG alone induces DHLNL and OHP crosslink formation; (2)subsequent laser exposure reduces the ICG-induced crosslinks down to native levels; (3)excessive diode laser exposure destroys normally occurring HLNL crosslinks.

  14. Polypoidal Choroidal Vasculopathy Associated with Optic Disc Coloboma

    Directory of Open Access Journals (Sweden)

    Yumiko Nakano

    2018-01-01

    Full Text Available Purpose: To report a case of polypoidal choroidal vasculopathy associated with optic disc coloboma. Methods: Case report. Results: A 50-year-old woman presented with optic disc coloboma and retinochoroidal coloboma associated with subretinal hemorrhage and serous retinal detachment (SRD in her left eye. Optical coherence tomography (OCT confirmed SRD at the macula and showed a sharply elevated retinal epithelial detachment at the choroidal excavation. OCT also revealed choroidal cavitation along the temporal side of the optic coloboma. Fluorescein angiography showed hyperfluorescent dye leakage and indocyanine green angiography revealed polypoidal lesions. We diagnosed polypoidal choroidal vasculopathy (PCV. PCV was located at the end of the choroidal cavitation. Her left eye was treated with an intraocular injection of the anti-vascular endothelial growth factor aflibercept (2 mg. Photodynamic therapy was performed using the standard protocol 1 week after the intravitreal application of aflibercept. One month after the combined treatment, OCT showed completely resolved SRD and her symptoms disappeared. Her best-corrected visual acuity remained stable and no recurrence was found during a 12-month follow-up period. Conclusion: PCV associated with optic disc coloboma has not been previously reported. The morphological abnormality of choroidal cavitation and choroidal excavation connecting with optic disc coloboma may contribute to the development of PCV in this case.

  15. Suture retraction technique to prevent parent vessel obstruction following aneurysm tandem clipping.

    Science.gov (United States)

    Rayan, Tarek; Amin-Hanjani, Sepideh

    2015-08-01

    With large or giant aneurysms, the use of multiple tandem clips can be essential for complete obliteration of the aneurysm. One potential disadvantage, however, is the considerable cumulative weight of these clips, which may lead to kinking of the underlying parent vessels and obstruction of flow. The authors describe a simple technique to address this problem, guided by intraoperative blood flow measurements, in a patient with a ruptured near-giant 2.2 × 1.7-cm middle cerebral artery bifurcation aneurysm that was treated with the tandem clipping technique. A total of 11 clips were applied in a vertical stacked fashion. The cumulative weight of the clips caused kinking of the temporal M2 branch of the bifurcation with reduction of flow. A 4-0 Nurolon suture tie was applied to the hub of one of the clips and was tethered to the dura of the sphenoid ridge by a small mini-clip and reinforced by application of tissue sealant. The patient underwent intraoperative indocyanine green videoangiography as well as catheter angiography, which demonstrated complete aneurysmal obliteration and preservation of vessel branches. Postoperative angiography confirmed patency of the bifurcation vessels with mild vasospasm. The patient had a full recovery with no postoperative complications and was neurologically intact at her 6-month follow-up. The suture retraction technique allows a simple solution to parent vessel obstruction following aneurysm tandem clipping, in conjunction with the essential guidance provided by intraoperative flow measurements.

  16. Meaning of visualizing retinal cone mosaic on adaptive optics images.

    Science.gov (United States)

    Jacob, Julie; Paques, Michel; Krivosic, Valérie; Dupas, Bénédicte; Couturier, Aude; Kulcsar, Caroline; Tadayoni, Ramin; Massin, Pascale; Gaudric, Alain

    2015-01-01

    To explore the anatomic correlation of the retinal cone mosaic on adaptive optics images. Retrospective nonconsecutive observational case series. A retrospective review of the multimodal imaging charts of 6 patients with focal alteration of the cone mosaic on adaptive optics was performed. Retinal diseases included acute posterior multifocal placoid pigment epitheliopathy (n = 1), hydroxychloroquine retinopathy (n = 1), and macular telangiectasia type 2 (n = 4). High-resolution retinal images were obtained using a flood-illumination adaptive optics camera. Images were recorded using standard imaging modalities: color and red-free fundus camera photography; infrared reflectance scanning laser ophthalmoscopy, fluorescein angiography, indocyanine green angiography, and spectral-domain optical coherence tomography (OCT) images. On OCT, in the marginal zone of the lesions, a disappearance of the interdigitation zone was observed, while the ellipsoid zone was preserved. Image recording demonstrated that such attenuation of the interdigitation zone co-localized with the disappearance of the cone mosaic on adaptive optics images. In 1 case, the restoration of the interdigitation zone paralleled that of the cone mosaic after a 2-month follow-up. Our results suggest that the interdigitation zone could contribute substantially to the reflectance of the cone photoreceptor mosaic. The absence of cones on adaptive optics images does not necessarily mean photoreceptor cell death. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. The formulation, characterization and in vivo evaluation of a magnetic carrier for brain delivery of NIR dye

    Energy Technology Data Exchange (ETDEWEB)

    Raut, S L; Kirthivasan, B; Bommana, M M; Squillante, E; Sadoqi, M, E-mail: squillae@stjohns.edu, E-mail: sadoqim@stjohns.edu [College of Pharmacy and Allied Health Professions, St John' s University, Queens, NY 11439 (United States)

    2010-10-01

    This work reports the targeting of the near infrared (NIR) dye indocyanine green (ICG) to the brain using composite nanoparticles. Thermal decomposition of iron pentacarbonyl was used to synthesize monodisperse oleic acid coated magnetic nanoparticles (OAMNP). Synthesized OAMNP and ICG were encapsulated in a poly (lactide-co-glycolide) matrix using an emulsion evaporation method. Different batches containing OAMNP:PLGA ratios (1:4, 1:2 and 3:4) were prepared with ICG (group B-1, 2, 3) and without ICG (group A-1, 2, 3) loading. All the formulations were characterized in terms of morphology, particle size, zeta potential, magnetic content, ICG encapsulation efficiency and the spectral properties of ICG. The optimized formulation showed an encapsulation efficiency of 56 {+-} 4.6% for ICG and 57 {+-} 1.37% for OAMNP. The biodistribution and brain targeting study involved three groups of six animals, each with 0.4 mg kg{sup -1} equivalent of ICG, given as neat ICG solution, composite nanoparticles without the aid of a magnetic field, and composite nanoparticles under the influence of a magnetic field (8000 G) to groups 1, 2 and 3 respectively. The tissue analysis and microscopy images revealed a significantly higher brain concentration of ICG (p < 0.05) for group 3 than the two control groups. These results are encouraging for the brain delivery of hydrophilic dyes/drugs using this method for biomedical applications.

  18. Differentiation of hepatocytes from induced pluripotent stem cells derived from human hair follicle mesenchymal stem cells.

    Science.gov (United States)

    Shi, Xu; Lv, Shuang; He, Xia; Liu, Xiaomei; Sun, Meiyu; Li, Meiying; Chi, Guangfan; Li, Yulin

    2016-10-01

    Due to the limitations of organ donors and immune rejection in severe liver diseases, stem cell-based therapy presents a promising application for tissue repair and regeneration. As a novel cell source, mesenchymal stem cells separated from human hair follicles (HF-MSCs) are convenient to obtain and have no age limit. To date, the differentiation of HF-MSCs into hepatocytes has not been reported. In this study, we explored whether HF-MSCs and HF-MSC-derived-induced pluripotent stem cells (HF-iPS) could differentiate into hepatocytes in vitro. Flow cytometry, Oil Red O stain and Alizarin Red stain were used to identify the characteristics of HF-MSCs. The expression of liver-specific gene was detected by immunofluorescence and Quantitative Polymerase Chain Reaction. Periodic Acid-Schiff stain, Indocyanine Green stain and Low-Density Lipoprotein stain were performed to evaluate the functions of induced hepatocyte-like cells (HLCs). HF-MSCs were unable to differentiate into HLCs using previously reported procedures for MSCs from other tissues. However, HF-iPS efficiently induced the generation of HLCs that expressed hepatocyte markers and drug metabolism-related genes. HF-iPS can be used as novel and alternative cellular tools for inducing hepatocytes in vitro, simultaneously benefiting from utilizing HF-MSCs as a noninvasive and convenient cell source for reprogramming.

  19. Real-time visualization and quantification of retrograde cardioplegia delivery using near infrared fluorescent imaging.

    Science.gov (United States)

    Rangaraj, Aravind T; Ghanta, Ravi K; Umakanthan, Ramanan; Soltesz, Edward G; Laurence, Rita G; Fox, John; Cohn, Lawrence H; Bolman, R M; Frangioni, John V; Chen, Frederick Y

    2008-01-01

    Homogeneous delivery of cardioplegia is essential for myocardial protection during cardiac surgery. Presently, there exist no established methods to quantitatively assess cardioplegia distribution intraoperatively and determine when retrograde cardioplegia is required. In this study, we evaluate the feasibility of near infrared (NIR) imaging for real-time visualization of cardioplegia distribution in a porcine model. A portable, intraoperative, real-time NIR imaging system was utilized. NIR fluorescent cardioplegia solution was developed by incorporating indocyanine green (ICG) into crystalloid cardioplegia solution. Real-time NIR imaging was performed while the fluorescent cardioplegia solution was infused via the retrograde route in five ex vivo normal porcine hearts and in five ex vivo porcine hearts status post left anterior descending (LAD) coronary artery ligation. Horizontal cross-sections of the hearts were obtained at proximal, middle, and distal LAD levels. Videodensitometry was performed to quantify distribution of fluorophore content. The progressive distribution of cardioplegia was clearly visualized with NIR imaging. Complete visualization of retrograde distribution occurred within 4 minutes of infusion. Videodensitometry revealed retrograde cardioplegia, primarily distributed to the left ventricle (LV) and anterior septum. In hearts with LAD ligation, antegrade cardioplegia did not distribute to the anterior LV. This deficiency was compensated for with retrograde cardioplegia supplementation. Incorporation of ICG into cardioplegia allows real-time visualization of cardioplegia delivery via NIR imaging. This technology may prove useful in guiding intraoperative decisions pertaining to when retrograde cardioplegia is mandated.

  20. Nanoparticles target early-stage breast cancer metastasis in vivo

    Science.gov (United States)

    Goldman, Evgeniya; Zinger, Assaf; da Silva, Dana; Yaari, Zvi; Kajal, Ashima; Vardi-Oknin, Dikla; Goldfeder, Mor; Schroeder, Josh E.; Shainsky-Roitman, Janna; Hershkovitz, Dov; Schroeder, Avi

    2017-10-01

    Despite advances in cancer therapy, treating cancer after it has metastasized remains an unmet clinical challenge. In this study we demonstrate that 100 nm liposomes target triple-negative murine breast-cancer metastases post intravenous administration. Metastatic breast cancer was induced in BALB/c mice either experimentally, by a tail vein injection of 4T1 cells, or spontaneously, after implanting a primary tumor xenograft. To track their biodistribution in vivo the liposomes were labeled with multi-modal diagnostic agents, including indocyanine green and rhodamine for whole-animal fluorescent imaging, gadolinium for magnetic resonance imaging (MRI), and europium for a quantitative biodistribution analysis. The accumulation of liposomes in the metastases peaked at 24 h post the intravenous administration, similar to the time they peaked in the primary tumor. The efficiency of liposomal targeting to the metastatic tissue exceeded that of a non-liposomal agent by 4.5-fold. Liposomes were detected at very early stages in the metastatic progression, including metastatic lesions smaller than 2 mm in diameter. Surprisingly, while nanoparticles target breast cancer metastasis, they may also be found in elevated levels in the pre-metastatic niche, several days before metastases are visualized by MRI or histologically in the tissue. This study highlights the promise of diagnostic and therapeutic nanoparticles for treating metastatic cancer, possibly even for preventing the onset of the metastatic dissemination by targeting the pre-metastatic niche.

  1. In vitro conjunctival incision repair by temperature-controlled laser soldering.

    Science.gov (United States)

    Norman, Galia; Rabi, Yaron; Assia, Ehud; Katzir, Abraham

    2009-01-01

    The common method of closing conjunctival incisions is by suturing, which is associated with several disadvantages. It requires skill to apply and does not always provide a watertight closure, which is required in some operations (e.g., glaucoma filtration). The purpose of the present study was to evaluate laser soldering as an alternative method for closing conjunctival incisions. Conjunctival incisions of 20 ex vivo porcine eyes were laser soldered using a temperature-controlled fiberoptic laser system and an albumin mixed with indocyanine green as a solder. The control group consisted of five repaired incisions by a 10-0 nylon running suture. The leak pressure of the repaired incisions was measured. The mean leak pressure in the laser-soldered group was 132 mm Hg compared to 4 mm Hg in the sutured group. There was no statistically significant difference in both the incision's length and distance from the limbus between the groups, before and after the procedure, indicating that there was no severe thermal damage. These preliminary results clearly demonstrate that laser soldering may be a useful method for achieving an immediate watertight conjunctival wound closure. This procedure is faster and easier to apply than suturing.

  2. A compact bio-inspired visible/NIR imager for image-guided surgery (Conference Presentation)

    Science.gov (United States)

    Gao, Shengkui; Garcia, Missael; Edmiston, Chris; York, Timothy; Marinov, Radoslav; Mondal, Suman B.; Zhu, Nan; Sudlow, Gail P.; Akers, Walter J.; Margenthaler, Julie A.; Liang, Rongguang; Pepino, Marta; Achilefu, Samuel; Gruev, Viktor

    2016-03-01

    Inspired by the visual system of the morpho butterfly, we have designed, fabricated, tested and clinically translated an ultra-sensitive, light weight and compact imaging sensor capable of simultaneously capturing near infrared (NIR) and visible spectrum information. The visual system of the morpho butterfly combines photosensitive cells with spectral filters at the receptor level. The spectral filters are realized by alternating layers of high and low dielectric constant, such as air and cytoplasm. We have successfully mimicked this concept by integrating pixelated spectral filters, realized by alternating silicon dioxide and silicon nitrate layers, with an array of CCD detectors. There are four different types of pixelated spectral filters in the imaging plane: red, green, blue and NIR. The high optical density (OD) of all spectral filters (OD>4) allow for efficient rejections of photons from unwanted bands. The single imaging chip weighs 20 grams with form factor of 5mm by 5mm. The imaging camera is integrated with a goggle display system. A tumor targeted agent, LS301, is used to identify all spontaneous tumors in a transgenic PyMT murine model of breast cancer. The imaging system achieved sensitivity of 98% and selectivity of 95%. We also used our imaging sensor to locate sentinel lymph nodes (SLNs) in patients with breast cancer using indocyanine green tracer. The surgeon was able to identify 100% of SLNs when using our bio-inspired imaging system, compared to 93% when using information from the lymphotropic dye and 96% when using information from the radioactive tracer.

  3. The Development of a Canine Anorectal Autotransplantation Model Based on Blood Supply: A Preliminary Case Report

    Science.gov (United States)

    Nakamura, Tatsuo; Sato, Tomoyuki; Naito, Munekazu; Fujii, Satoshi; Mihara, Makoto; Koshima, Isao

    2012-01-01

    Colostomy is conventionally the only treatment for anal dysfunction. Recently, a few trials of anorectal transplantation in animals have been published; however, further development of this technique is required. Moreover, it is crucial to perform this research in dogs, which resemble humans in anorectal anatomy and biology. We designed a canine anorectal transplantation model, wherein anorectal autotransplantation was performed by anastomoses of the rectum, inferior mesenteric artery (IMA) and vein, and pudendal nerves. Resting pressure in the anal canal and anal canal pressure fluctuation were measured before and after surgery. Graft pathology was examined three days after surgery. The anal blood supply was compared with that in three beagles using indocyanine green (ICG) fluorescence angiography. The anorectal graft had sufficient arterial blood supply from the IMA; however, the graft’s distal end was congested and necrotized. Functional examination demonstrated reduced resting pressure and the appearance of an irregular anal canal pressure wave after surgery. ICG angiography showed that the pudendal arteries provided more blood flow than the IMA to the anal segment. This is the first canine model of preliminary anorectal autotransplantation, and it demonstrates the possibility of establishing a transplantation model in dogs using appropriate vascular anastomoses, thus contributing to the progress of anorectal transplantation. PMID:22970198

  4. A portable fluorescence microscopic imaging system for cholecystectomy

    Science.gov (United States)

    Ye, Jian; Yang, Chaoyu; Gan, Qi; Ma, Rong; Zhang, Zeshu; Chang, Shufang; Shao, Pengfei; Zhang, Shiwu; Liu, Chenhai; Xu, Ronald

    2016-03-01

    In this paper we proposed a portable fluorescence microscopic imaging system to prevent iatrogenic biliary injuries from occurring during cholecystectomy due to misidentification of the cystic structures. The system consisted of a light source module, a CMOS camera, a Raspberry Pi computer and a 5 inch HDMI LCD. Specifically, the light source module was composed of 690 nm and 850 nm LEDs, allowing the CMOS camera to simultaneously acquire both fluorescence and background images. The system was controlled by Raspberry Pi using Python programming with the OpenCV library under Linux. We chose Indocyanine green(ICG) as a fluorescent contrast agent and then tested fluorescence intensities of the ICG aqueous solution at different concentration levels by our fluorescence microscopic system compared with the commercial Xenogen IVIS system. The spatial resolution of the proposed fluorescence microscopic imaging system was measured by a 1951 USAF resolution target and the dynamic response was evaluated quantitatively with an automatic displacement platform. Finally, we verified the technical feasibility of the proposed system in mouse models of bile duct, performing both correct and incorrect gallbladder resection. Our experiments showed that the proposed system can provide clear visualization of the confluence between the cystic duct and common bile duct or common hepatic duct, suggesting that this is a potential method for guiding cholecystectomy. The proposed portable system only cost a total of $300, potentially promoting its use in resource-limited settings.

  5. Efficacy of intravitreal Ranibizumab injection for choroidal neovascularization secondary to pathologic myopia

    Directory of Open Access Journals (Sweden)

    Li-Hong Cui

    2016-03-01

    Full Text Available AIM:To observe the efficacy and safety of intravitreal Ranibizumab injection in patiens with choroidal neovascularization(CNVsecondary to pathologic myopia.METHODS:In this retrospective and comparative study,24 patients(25 eyeswith CNV secondary to pathologic myopia were enrolled. All patients were assessed by examinations of ETDRS visual acuity chart, preplaced-mirror ophthalmoscopy, fundus fluorescein angiography(FFA, indocyanine green angiography(ICGAand optical coherence tomography(OCT. Patiens received intravitreally injected ranibizumab 0.5mg(0.05mL. Treatments were repeated if the follow-up indicated that it was necessary. The follow-up periods were 4~10mo. Best corrected visual acuity(BCVA, central macular thickness(CMTand leakage of CNV before and after the treatment were compared. RESULTS:No local or systemic complications occurred in any patients during the treatment or follow-up. The average time of injection was 1.52. The mean BCVA was 23.93±12.46 letters before the therapy. In the last follow-up, the mean BCVA was 40.63±7.25 letters, improved by 14.27±9.36 letters and the difference was statically significant(t=5.74, Pt=3.96, PCONCLUSION:Intravitreal ranibizumab injection for CNV secondary to pathologic myopia is safe and effective, and this treatment can improve visual acuity, reduce retina edema and leakage of CNV.

  6. Liver function assessment using 99mTc-GSA single-photon emission computed tomography (SPECT)/CT fusion imaging in hilar bile duct cancer: A retrospective study.

    Science.gov (United States)

    Sumiyoshi, Tatsuaki; Shima, Yasuo; Okabayashi, Takehiro; Kozuki, Akihito; Hata, Yasuhiro; Noda, Yoshihiro; Kouno, Michihiko; Miyagawa, Kazuyuki; Tokorodani, Ryotaro; Saisaka, Yuichi; Tokumaru, Teppei; Nakamura, Toshio; Morita, Sojiro

    2016-07-01

    The objective of this study was to determine the utility of Tc-99m-diethylenetriamine-penta-acetic acid-galactosyl human serum albumin ((99m)Tc-GSA) single-photon emission computed tomography (SPECT)/CT fusion imaging for posthepatectomy remnant liver function assessment in hilar bile duct cancer patients. Thirty hilar bile duct cancer patients who underwent major hepatectomy with extrahepatic bile duct resection were retrospectively analyzed. Indocyanine green plasma clearance rate (KICG) value and estimated KICG by (99m)Tc-GSA scintigraphy (KGSA) and volumetric and functional rates of future remnant liver by (99m)Tc-GSA SPECT/CT fusion imaging were used to evaluate preoperative whole liver function and posthepatectomy remnant liver function, respectively. Remnant (rem) KICG (= KICG × volumetric rate) and remKGSA (= KGSA × functional rate) were used to predict future remnant liver function; major hepatectomy was considered unsafe for values liver were significantly higher than volumetric rates (median: 0.54 vs 0.46; P liver failure and mortality did not occur in the patients for whom hepatectomy was considered unsafe based on remKICG. remKGSA showed a stronger correlation with postoperative prothrombin time activity than remKICG. (99m)Tc-GSA SPECT/CT fusion imaging enables accurate assessment of future remnant liver function and suitability for hepatectomy in hilar bile duct cancer patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. The association of elastin gene variants with two angiographic subtypes of polypoidal choroidal vasculopathy.

    Directory of Open Access Journals (Sweden)

    Suiho Yanagisawa

    Full Text Available To compare the association of elastin (ELN gene variants between two different angiographic phenotypes of polypoidal choroidal vasculopathy (PCV.We included 411 treatment-naïve PCV patients and 350 controls in the present study. PCV was classified into two phenotypes (152 Type 1 and 259 Type 2 according to the presence or absence of feeding vessels found in indocyanine-green angiography. Single nucleotide polymorphisms (SNPs in the ELN region including rs868005, rs884843, rs2301995, rs13239907 and rs2856728 were genotyped using TaqMan Genotyping Assays.In the allelic association analyses, rs868005 showed the strongest association with Type 2 PCV (allelic odds ratio 1.56; p = 7.4x10(-6, while no SNP was significantly associated with Type 1 PCV. Genotype association analyses revealed the significant association of rs868005 with Type 2 PCV in log additive model and predominant model (odds ratio 1.75; p = 1.5x10(-6 and odds ratio 1.60; p = 0.0044, respectively, but not with Type 1 PCV. These findings were further corroborated by another control group in the literature.There may be significantly different associations in genetic variants of elastin between two angiographic phenotypes of PCV.

  8. Laser welding in penetrating keratoplasty and cataract surgery of pediatric patients: early results

    Science.gov (United States)

    Rossi, Francesca; Pini, Roberto; Menabuoni, Luca; Malandrini, Alex; Canovetti, Annalisa; Lenzetti, Ivo; Capozzi, Paolo; Valente, Paola; Buzzonetti, Luca

    2013-03-01

    Diode laser welding of ocular tissues is a procedure that enables minimally invasive closure of a corneal wound. This procedure is based on a photothermal effect: a water solution of Indocyanine Green (ICG) is inserted in the surgical wound, in order to stain the corneal tissue walls. The stained tissue is then irradiated with a low power infrared diode laser, delivering laser light through a 300-μm core diameter optical fiber. This procedure enables an immediate closure of the wounds: it is thus possible to reduce or to substitute the use of surgical threads. This is of particular interest in children, because the immediate closure improves refractive outcome and anti-amblyopic effect; moreover this procedure avoids several general anaesthesia for suture management. In this work, we present the first use of diode laser welding procedure in paediatric patients. 5 selected patients underwent cataract surgery (Group 1), while 4 underwent fs-laserassisted penetrating keratoplasty (Group 2). In Group 1 the conventional surgery procedure was performed, while no stitches were used for the closure of the surgical wounds: these were laser welded and immediately closed. In Group 2 the donor button was sutured upon the recipient by 8 single stitches, instead of 16 single stitches or a running suture. The laser welding procedure was performed in order to join the donor tissue to the recipient bed. Objective observations in the follow up study evidenced a perfect adhesion of the laser welded tissues, no collateral effects and an optimal restoration of the treated tissues.

  9. Sutureless closure of scleral wounds in animal models by the use of laser welded biocompatible patches

    Science.gov (United States)

    Rossi, Francesca; Matteini, Paolo; Menabuoni, Luca; Lenzetti, Ivo; Pini, Roberto

    2011-03-01

    The common procedures used to seal the scleral or conjunctival injuries are based on the traditional suturing techniques, that may induce foreign body reaction during the follow up, with subsequent inflammation and distress for the patient. In this work we present an experimental study on the laser welding of biocompatible patches onto ocular tissues, for the closure of surgical or trauma wounds. The study was performed ex vivo in animal models (porcine eyes). A penetrating perforation of the ocular tissue was performed with a surgical knife. The wound walls were approximated, and a biocompatible patch was put onto the outer surface of the tissue, in order to completely cover the wound as a plaster. The patches were prepared with a biocompatible and biodegradable polymer, showing high mechanical strength, good elasticity, high permeability for vapour and gases and rather low biodegradation. During preparation, Indocyanine Green (ICG) was included in the biopolymeric matrix, so that the films presented high absorption at 810 nm. Effective adhesion of the membranes to the ocular tissues was obtained by using diode laser light emitted from an 810 nm diode laser and delivered by means of a 300 μm core diameter optical fiber, to produce spots of local film/tissue adhesion, due to the photothermal effect at the interface. The result is an immediate closure of the wound, thus reducing post-operative complications due to inflammation.

  10. IRDye78 Conjugates for Near-Infrared Fluorescence Imaging

    Directory of Open Access Journals (Sweden)

    Atif Zaheer

    2002-10-01

    Full Text Available The detection of human malignancies by near-infrared (NIR fluorescence will require the conjugation of cancer-specific ligands to NIR fluorophores that have optimal photoproperties and pharmacokinetics. IRDye78, a tetra-sulfonated heptamethine indocyanine NIR fluorophore, meets most of the criteria for an in vivo imaging agent, and is available as an N-hydroxysuccinimide ester for conjugation to low-molecular-weight ligands. However, IRDye78 has a high charge-to-mass ratio, complicating purification of conjugates. It also has a potentially labile linkage between fluorophore and ligand. We have developed an ion-pairing purification strategy for IRDye78 that can be performed with a standard C18 column under neutral conditions, thus preserving the stability of fluorophore, ligand, and conjugate. By employing parallel evaporative light scatter and absorbance detectors, all reactants and products are identified, and conjugate purity is maximized. We describe reversible and irreversible conversions of IRDye78 that can occur during sample purification, and describe methods for preserving conjugate stability. Using seven ligands, spanning several classes of small molecules and peptides (neutral, charged, and/or hydrophobic, we illustrate the robustness of these methods, and confirm that IRDye78 conjugates so purified retain bioactivity and permit NIR fluorescence imaging of specific targets.

  11. Quantitation of Brown Adipose Tissue Perfusion in Transgenic Mice Using Near-Infrared Fluorescence Imaging

    Directory of Open Access Journals (Sweden)

    Akira Nakayama

    2003-01-01

    Full Text Available Brown adipose tissue (BAT; brown fat is the principal site of adaptive thermogenesis in the human newborn and other small mammals. Of paramount importance for thermogenesis is vascular perfusion, which controls the flow of cool blood in, and warmed blood out, of BAT. We have developed an optical method for the quantitative imaging of BAT perfusion in the living, intact animal using the heptamethine indocyanine IR-786 and near-infrared (NIR fluorescent light. We present a detailed analysis of the physical, chemical, and cellular properties of IR-786, its biodistribution and pharmacokinetics, and its uptake into BAT. Using transgenic animals with homozygous deletion of Type II iodothyronine deiodinase, or homozygous deletion of uncoupling proteins (UCPs 1 and 2, we demonstrate that BAT perfusion can be measured noninvasively, accurately, and reproducibly. Using these techniques, we show that UCP 1/2 knockout animals, when compared to wild-type animals, have a higher baseline perfusion of BAT but a similar maximal response to β3-receptor agonist. These results suggest that compensation for UCP deletion is mediated, in part, by the control of BAT perfusion. Taken together, BAT perfusion can now be measured noninvasively using NIR fluorescent light, and pharmacological modulators of thermogenesis can be screened at relatively high throughput in living animals.

  12. Time-resolved near-infrared technique for bedside monitoring of absolute cerebral blood flow

    Science.gov (United States)

    Diop, Mamadou; Tichauer, Kenneth M.; Elliott, Jonathan T.; Migueis, Mark; Lee, Ting-Yim; St. Lawrence, Keith

    2010-02-01

    A primary focus of neurointensive care is monitoring the injured brain to detect harmful events that can impair cerebral blood flow (CBF). Since current non-invasive bedside methods can only indirectly assess blood flow, the goal of this research was to develop an optical technique for measuring absolute CBF. A time-resolved near-infrared (NIR) apparatus was built and its ability to accurately measure changes in optical properties was demonstrated in tissue-mimicking phantoms. The time-resolved system was combined with a bolus-tracking method for measuring CBF using the dye indocyanine green (ICG) as an intravascular flow tracer. Cerebral blood flow was measured in newborn piglets and for comparison, CBF was concurrently measured using a previously developed continuous-wave NIR method. Measurements were acquired with both techniques under three conditions: normocapnia, hypercapnia and following occlusion of the carotid arteries. Mean CBF values (N = 3) acquired with the TR-NIR system were 31.9 +/- 11.7 ml/100g/min during occlusion, 39.7 +/- 1.6 ml/100g/min at normocapnia, and 58.8 +/- 9.9 ml/100g/min at hypercapnia. Results demonstrate that the developed TR-NIR technique has the sensitivity to measure changes in CBF; however, the CBF measurements were approximately 25% lower than the values obtained with the CW-NIRS technique.

  13. Comparison of time-resolved and continuous-wave near-infrared techniques for measuring cerebral blood flow in piglets

    Science.gov (United States)

    Diop, Mamadou; Tichauer, Kenneth M.; Elliott, Jonathan T.; Migueis, Mark; Lee, Ting-Yim; Lawrence, Keith St.

    2010-09-01

    A primary focus of neurointensive care is monitoring the injured brain to detect harmful events that can impair cerebral blood flow (CBF), resulting in further injury. Since current noninvasive methods used in the clinic can only assess blood flow indirectly, the goal of this research is to develop an optical technique for measuring absolute CBF. A time-resolved near-infrared (TR-NIR) apparatus is built and CBF is determined by a bolus-tracking method using indocyanine green as an intravascular flow tracer. As a first step in the validation of this technique, CBF is measured in newborn piglets to avoid signal contamination from extracerebral tissue. Measurements are acquired under three conditions: normocapnia, hypercapnia, and following carotid occlusion. For comparison, CBF is concurrently measured by a previously developed continuous-wave NIR method. A strong correlation between CBF measurements from the two techniques is revealed with a slope of 0.79+/-0.06, an intercept of -2.2+/-2.5 ml/100 g/min, and an R2 of 0.810+/-0.088. Results demonstrate that TR-NIR can measure CBF with reasonable accuracy and is sensitive to flow changes. The discrepancy between the two methods at higher CBF could be caused by differences in depth sensitivities between continuous-wave and time-resolved measurements.

  14. Nanoscaled red blood cells facilitate breast cancer treatment by combining photothermal/photodynamic therapy and chemotherapy.

    Science.gov (United States)

    Wan, Guoyun; Chen, Bowei; Li, Ling; Wang, Dan; Shi, Shurui; Zhang, Tao; Wang, Yue; Zhang, Lianyun; Wang, Yinsong

    2018-02-01

    Red blood cells (RBCs)-based vesicles have been widely used for drug delivery due to their unique advantages. Intact RBCs contain a large amount of oxyhemoglobin (oxyHb), which can assist with photodynamic therapy (PDT). Indocyanine green (ICG), a photosensitizer both for photothermal therapy (PTT) and PDT, shows potent anticancer efficacy when combined with chemotherapeutic drug doxorubicin (DOX). In this study, we prepared nanoscaled RBCs (RAs) containing oxyHb and gas-generating agent ammonium bicarbonate (ABC) for co-loading and controlled release of ICG and DOX, thus hoping to achieve synergistic effects of PTT/PDT and chemotherapy against breast cancer. Compared to free ICG, ICG and DOX co-loaded RAs (DIRAs) exhibited nearly identical PTT efficiency both in vitro and in vivo, but meanwhile their PDT efficiency was enhanced significantly. In mouse breast cancer cells, DIRAs significantly inhibited cell growth and induced cell apoptosis after laser irradiation. In breast tumor-bearing mice, intratumoral injection of DIRAs and followed by local laser irradiation almost completely ablated breast tumor and further suppressed tumor recurrence and metastasis. In conclusion, this biomimetic multifunctional nanosystem can facilitate breast cancer treatment by combining PTT/PDT and chemotherapy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Quantitative fluorescence angiography for neurosurgical interventions.

    Science.gov (United States)

    Weichelt, Claudia; Duscha, Philipp; Steinmeier, Ralf; Meyer, Tobias; Kuß, Julia; Cimalla, Peter; Kirsch, Matthias; Sobottka, Stephan B; Koch, Edmund; Schackert, Gabriele; Morgenstern, Ute

    2013-06-01

    Present methods for quantitative measurement of cerebral perfusion during neurosurgical operations require additional technology for measurement, data acquisition, and processing. This study used conventional fluorescence video angiography--as an established method to visualize blood flow in brain vessels--enhanced by a quantifying perfusion software tool. For these purposes, the fluorescence dye indocyanine green is given intravenously, and after activation by a near-infrared light source the fluorescence signal is recorded. Video data are analyzed by software algorithms to allow quantification of the blood flow. Additionally, perfusion is measured intraoperatively by a reference system. Furthermore, comparing reference measurements using a flow phantom were performed to verify the quantitative blood flow results of the software and to validate the software algorithm. Analysis of intraoperative video data provides characteristic biological parameters. These parameters were implemented in the special flow phantom for experimental validation of the developed software algorithms. Furthermore, various factors that influence the determination of perfusion parameters were analyzed by means of mathematical simulation. Comparing patient measurement, phantom experiment, and computer simulation under certain conditions (variable frame rate, vessel diameter, etc.), the results of the software algorithms are within the range of parameter accuracy of the reference methods. Therefore, the software algorithm for calculating cortical perfusion parameters from video data presents a helpful intraoperative tool without complex additional measurement technology.

  16. Preliminary study of Conbercept injected intravitreally for the treatment of wet age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Ying Qin

    2017-08-01

    Full Text Available AIM:To observe the preliminary efficacy of conbercept injected intravitreally for the treatment of wet age-related macular degeneration(wAMD.METHODS:Seventeen wAMD patients(18 eyeswere selected to receive conbercept injection. All patients were given a single conbercept injection every month, 3 times. Before and after 1, 2, 3mo of the injection, the best corrected visual acuity(BCVA, intraocular pressure(IOP, measured by Non-contact tonometer, fundus photography, fundus fluorescein angiography(FFA, indocyanine green angiography(ICG, optical coherence tomography(OCTexamination and the complications incidence were compared.RESULTS:Three months after conbercept injection, the BCVA improved in 15 eyes(83%, stable in 3 eyes(17%. Before treatment, the average central macular thickness was 421.72±54.43μm, at 1 and 2 and 3mo after treatment, the average central macular thickness was 337.89±25.88μm, 293.56±26.87μm, 266.89±19.10μm respectively. There were significant differences compared with before and after injection(PCONCLUSION:Intravitreal injection conbercept for wAMD can significantly improve the visual function, reduce the macular edema and the leakage with higher safety and less complications. However the prolonged efficacy needs further observation.

  17. Development of an Extracorporeal Perfusion Device for Small Animal Free Flaps.

    Directory of Open Access Journals (Sweden)

    Andreas M Fichter

    Full Text Available Extracorporeal perfusion (ECP might prolong the vital storage capabilities of composite free flaps, potentially opening a wide range of clinical applications. Aim of the study was the development a validated low-cost extracorporeal perfusion model for further research in small animal free flaps.After establishing optimal perfusion settings, a specially designed extracorporeal perfusion system was evaluated during 8-hour perfusion of rat epigastric flaps followed by microvascular free flap transfer. Controls comprised sham-operation, ischemia and in vivo perfusion. Flaps and perfusate (diluted blood were closely monitored by blood gas analysis, combined laser Doppler flowmetry and remission spectroscopy and Indocyanine-Green angiography. Evaluations were complemented by assessment of necrotic area and light microscopy at day 7.ECP was established and maintained for 8 hours with constant potassium and pH levels. Subsequent flap transfer was successful. Notably, the rate of necrosis of extracorporeally perfused flaps (27% was even lower than after in vivo perfusion (49%, although not statistically significant (P = 0,083. After sham-operation, only 6% of the total flap area became necrotic, while 8-hour ischemia led to total flap loss (98%. Angiographic and histological findings confirmed these observations.Vital storage capabilities of microvascular flaps can be prolonged by temporary ECP. Our study provides important insights on the pathophysiological processes during extracorporeal tissue perfusion and provides a validated small animal perfusion model for further studies.

  18. Optical coherence tomography angiography in acute arteritic and non-arteritic anterior ischemic optic neuropathy.

    Science.gov (United States)

    Balducci, Nicole; Morara, Mariachiara; Veronese, Chiara; Barboni, Piero; Casadei, Nicoletta Lelli; Savini, Giacomo; Parisi, Vincenzo; Sadun, Alfredo A; Ciardella, Antonio

    2017-11-01

    The purpose of our study was to describe the feature of acute non-arteritic or arteritic anterior ischemic optic neuropathy (NA-AION and A-AION) using optical coherence tomography angiography (OCT-A) and to compare it with fluorescein angiography (FA) and indocyanine green angiography (ICGA). In this retrospective, observational case-control study four NA-AION patients and one A-AION patient were examined by FA, ICGA and OCT-A within 2 weeks from disease presentation. The characteristics of the images were analyzed. Optic nerve head (ONH) and radial peripapillary capillaries (RPC) vessel densities (VDs) were compared between NA-AION and controls. In two of four NA-AION cases and in the A-AION patient, OCT-A clearly identified the boundary of the ischemic area at the level of the optic nerve head, which was comparable to optic disc filling defects detected by FA. In the other two NA-AION cases, a generalized leakage from the disc was visible with FA, yet OCT-A still demonstrated sectorial peripapillary capillary network reduction. Both ONH and RPC VDs were reduced in NA-AION patients, when compared to controls. OCT-A was able to identify microvascular defects and VD reduction in cases of acute optic disc edema due to NA-AION and A-AION. OCT-A provides additional information in ischemic conditions of the optic nerve head.

  19. Simultaneous Confocal Scanning Laser Ophthalmoscopy Combined with High-Resolution Spectral-Domain Optical Coherence Tomography: A Review

    Directory of Open Access Journals (Sweden)

    Verônica Castro Lima

    2011-01-01

    Full Text Available We aimed to evaluate technical aspects and the clinical relevance of a simultaneous confocal scanning laser ophthalmoscope and a high-speed, high-resolution, spectral-domain optical coherence tomography (SDOCT device for retinal imaging. The principle of confocal scanning laser imaging provides a high resolution of retinal and choroidal vasculature with low light exposure. Enhanced contrast, details, and image sharpness are generated using confocality. The real-time SDOCT provides a new level of accuracy for assessment of the angiographic and morphological correlation. The combined system allows for simultaneous recordings of topographic and tomographic images with accurate correlation between them. Also it can provide simultaneous multimodal imaging of retinal pathologies, such as fluorescein and indocyanine green angiographies, infrared and blue reflectance (red-free images, fundus autofluorescence images, and OCT scans (Spectralis HRA + OCT; Heidelberg Engineering, Heidelberg, Germany. The combination of various macular diagnostic tools can lead to a better understanding and improved knowledge of macular diseases.

  20. Atypical vitelliform macular dystrophy misdiagnosed as chronic central serous chorioretinopathy: case reports

    Directory of Open Access Journals (Sweden)

    Lee Young

    2012-07-01

    Full Text Available Abstract Background To report two cases of atypical vitelliform macular dystrophy misdiagnosed as chronic central serous chorioretinopathy. Case presentation Two patients with incidentally discovered abnormalities of the retina without specific symptoms were referred to our hospital for consultation. Bilateral macula atrophic lesions were observed and optical coherence tomography revealed serous retinal detachment in the macula. Fluorescein angiography showed multiple leakages around the central hypofluorescent area and indocyanine green angiography showed partially dilated choroidal vessels. Fundus autofluorescence (FAF showed a decreasing pattern of autofluorescence in the subretinal fluid area, and increasing autofluorescence at the border of the serous retinal detachment. Both patients were diagnosed with chronic central serous chorioretinopathy. Photodynamic therapy and intravitreal bevacizumab injection were administered for engorged choroidal vessels during follow-up, but neither patient showed improvement in symptoms or ophthalmologic findings. Based on re-evaluation by fundus photography, optical coherence tomography, fluorescein angiography, and comparison of the results of FAF with the first visit, vitelliform macular dystrophy was suspected and a definite diagnosis was made by electrooculography and genetic testing. Conclusion In patients with continuous serous retinal detachment without response to photodynamic therapy or intravitreal bevacizumab injection, careful fundus exam and FAF can be used to diagnose atypical vitelliform macular dystrophy.

  1. Infrared imaging and spectral-domain optical coherence tomography findings correlate with microperimetry in acute macular neuroretinopathy: a case report

    Directory of Open Access Journals (Sweden)

    Grover Sandeep

    2011-10-01

    Full Text Available Abstract Introduction Spectral-domain optical coherence tomography findings in a patient with acute macular neuroretinopathy, and correlation with functional defects on microperimetry, are presented. Case presentation A 25-year old Caucasian woman presented with bitemporal field defects following an upper respiratory tract infection. Her visual acuity was 20/20 in both eyes and a dilated fundus examination revealed bilateral hyperpigmentary changes in the papillomacular bundle. Our patient underwent further evaluation with spectral-domain optical coherence tomography, infrared and fundus autofluorescence imaging. Functional changes were assessed by microperimetry. Infrared imaging showed the classic wedge-shaped defects and spectral-domain optical coherence tomography exhibited changes at the inner segment-outer segment junction, with a thickened outer plexiform layer overlying these areas. Fluorescein and indocyanine green angiography did not demonstrate any perfusion defects or any other abnormality. Microperimetry demonstrated focal elevation in threshold correlating with the wedge-shaped defects in both eyes. Conclusion Spectral-domain optical coherence tomography findings provide new evidence of the involvement of the outer plexiform layer of the retina in acute macular neuroretinopathy.

  2. “En-Face” Spectral-Domain Optical Coherence Tomography Findings in Multiple Evanescent White Dot Syndrome

    Directory of Open Access Journals (Sweden)

    Flore De bats

    2014-01-01

    Full Text Available Purpose. The recent use of “en-face” enhanced-depth imaging spectral-domain optical coherence tomography (EDI SD-OCT helps distinguish the retinal layers involved in the physiopathology of multiple evanescent white dot syndrome (MEWDS. Methods. Four patients presenting with MEWDS underwent a comprehensive ocular examination including C-scan (“en-face” EDI SD-OCT at the initial visit and during follow-up. Results. C-scans combined with the other multimodal imaging enabled the visualization of retinal damage. Acute lesions appeared as diffuse and focal disruptions occurring in the ellipsoid and interdigitation zones. The match between autofluorescence imaging, indocyanine green angiography, and “en-face” OCT helped identify the acute microstructural damages in the outer retina further than the choroid. Follow-up using “en-face” EDI-OCT revealed progressive and complete recovery of the central outer retinal layers. Conclusion. “En-face” EDI SD-OCT identified the site of initial damage in MEWDS as the photoreceptors and the interdigitation layers rather than the choroid. Moreover, “en-face” OCT is helpful in the follow-up of these lesions by being able to show the recovery of the outer retinal layers.

  3. Retinal pigment epithelial changes in chronic Vogt-Koyanagi-Harada disease: fundus autofluorescence and spectral domain optical coherence tomography findings

    Science.gov (United States)

    Vasconcelos-Santos, Daniel V.; Sohn, Elliott H.; Sadda, Srinivas; Rao, Narsing A.

    2009-01-01

    Purpose To determine whether fundus autofluorescence (FAF) and spectral-domain optical coherence tomography (SD-OCT) imaging allows better assessment of RPE and outer retina (OR) in subjects with chronic VKH compared to examination and angiography alone. Methods Cross-sectional analysis of a series of seven consecutive patients with chronic VKH undergoing FAF and SD-OCT. Chronic VKH was defined as during >3 months. Color fundus photographs were correlated to FAF and SD-OCT images. The images were later correlated to fluorescein angiography (FA) and indocyanine green angiography (ICG-A). Results All patients had sunset glow fundus, which resulted in no apparent corresponding abnormality on FAF or SD-OCT. Lesions with decreased autofluorescence signal were observed in 11 eyes (85%), being associated with loss of the RPE and involvement of OR on SD-OCT. In 5 eyes (38%) some of these lesions were very subtle on clinical examination but easily detected by FAF. Lesions with increased autofluorescence signal were seen in 8 eyes (61.5%), showing variable involvement of the OR on SD-OCT and corresponding clinically to areas of RPE proliferation and cystoid macular edema. Conclusion Combined use of FAF and SD-OCT imaging allowed noninvasive delineation of RPE/OR changes in patients with chronic VKH, which were consistent with previous histopathological reports. Some of these changes were not apparent on clinical examination. PMID:20010321

  4. Chronic central serous choroidopathy with severe visual loss in hyperopic microphthalmic identical twins

    Directory of Open Access Journals (Sweden)

    Fabry, Annelies

    2011-01-01

    Full Text Available Objective: To report chronic central serous choroidopathy with severe visual loss in hyperopic microphthalmic identical twins. Methods: The index patient was first examined in 1994, at age 31, and has been followed up closely for 17 years. He had repeated fluorescein and indocyanine green angiograms, OCT, ultrasound biometry, and recently also autofluorescence and EDI OCT. His twin brother was first examined in 2010, at age 47, and had a similar extensive exploration. Results: The index patient had a mean refractive error of +6 D OU and VA was 20/32++ in the RE and 20/200 in the LE in 1994. Vision slowly went down to 20/800+ in the RE and 20/600 in the LE in 2011. His twin brother has a mean refractive error of +6 D OU and VA 20/400 OU. Both have a short axial length of the eye, a thick choroid with dilated vessels, and central serous choroidopathy with cystic degeneration of the macula and retina in the posterior pole. Conclusions: We add to the reported complications of microphthalmos, chronic central serous choroidopathy.

  5. Long-term effects of short-term retinal bleb detachments in rabbits.

    Science.gov (United States)

    Ivert, Lena; Kjeldbye, Hild; Gouras, Peter

    2002-03-01

    To examine the effects of saline-induced bleb detachments in rabbit retina. Retinal bleb detachments were produced by the injection of 50 microl of balanced salt solution (BSS) into the subretinal space of one eye of each of six rabbits using a glass pipette with a flat tip, 50 microm in diameter. The retina was examined by biomicroscopy, scanning laser ophthalmoscopy (SLO), auto-fluorescence and simultaneous fluorescein and indocyanine green (ICG) angiography. Histological examination was carried out at 1, 2, 3 and 4 months after surgery. All rabbits showed leakage of fluorescein for at least a day after detachment, but within 1 month the leakage ceased. ICG staining developed gradually at the level of the RPE or Bruch's membrane near sites of previous staining. Lipofuscin fluorescence also developed gradually around areas of staining. Histology revealed the source of the excessive lipofuscin to be in the RPE layer, especially in cells migrating away from Bruch's membrane. Short-term bleb detachments cause a transient breakdown in the blood-retinal barrier, long-term ICG staining at or deep to the RPE layer, hyperlipofuscinosis and migration of the RPE. The abnormal lipofuscin accumulation is apparent on fluorescence ophthalmoscopy and can be confused with markers such as green fluorescent protein.

  6. The association of age-related maculopathy susceptibility 2 (ARMS2) and complement factor H (CFH) variants with two angiographic subtypes of polypoidal choroidal vasculopathy.

    Science.gov (United States)

    Miki, Akiko; Honda, Shigeru; Kondo, Naoshi; Negi, Akira

    2013-09-01

    To compare the association of age-related maculopathy susceptibility 2 (ARMS2) and complement factor H (CFH) variants between two different angiographic phenotypes of polypoidal choroidal vasculopathy (PCV). We included 175 Japanese patients with PCV and 150 age- and sex-matched controls. PCV was classified into two phenotypes (Type 1 and Type 2) according to the presence or absence of the feeding vessels found in indocyanine-green angiography. The single nucleotide polymorphism (SNP) at rs10490924 (A69S) in ARMS2 and rs800292 (I62V), rs1061170 (Y402H) in the CFH region were genotyped using the TaqMan assay. The minor allele frequency (MAF) of rs10490924 was significantly different between Type 1 PCV (n = 81) and control (p < 0.0001), while no difference was found between Type 2 PCV (n = 94) and control (p = 0.20). The MAF of rs800292 was significantly different between each type of PCV and control (p < 0.0001 and 0.0001 for Type 1 versus control and Type 2 versus control, respectively). The MAF of rs1061170 was not significantly different between either type of PCV and control (p = 0.084 and 0.15, respectively). There may be significantly different associations in the genetic variants of ARMS2 between two angiographic phenotypes of PCV.

  7. Non-invasive assessment of the liver using imaging

    Science.gov (United States)

    Thorling Thompson, Camilla; Wang, Haolu; Liu, Xin; Liang, Xiaowen; Crawford, Darrell H.; Roberts, Michael S.

    2016-12-01

    Chronic liver disease causes 2,000 deaths in Australia per year and early diagnosis is crucial to avoid progression to cirrhosis and end stage liver disease. There is no ideal method to evaluate liver function. Blood tests and liver biopsies provide spot examinations and are unable to track changes in function quickly. Therefore better techniques are needed. Non-invasive imaging has the potential to extract increased information over a large sampling area, continuously tracking dynamic changes in liver function. This project aimed to study the ability of three imaging techniques, multiphoton and fluorescence lifetime imaging microscopy, infrared thermography and photoacoustic imaging, in measuring liver function. Collagen deposition was obvious in multiphoton and fluorescence lifetime imaging in fibrosis and cirrhosis and comparable to conventional histology. Infrared thermography revealed a significantly increased liver temperature in hepatocellular carcinoma. In addition, multiphoton and fluorescence lifetime imaging and photoacoustic imaging could both track uptake and excretion of indocyanine green in rat liver. These results prove that non-invasive imaging can extract crucial information about the liver continuously over time and has the potential to be translated into clinic in the assessment of liver disease.

  8. Adjunctive Application of Antimicrobial Photodynamic Therapy in Nonsurgical Periodontal Treatment: A Review of Literature

    Directory of Open Access Journals (Sweden)

    Takeshi Kikuchi

    2015-10-01

    Full Text Available Periodontal disease is caused by dental plaque biofilms, and the removal of these biofilms from the root surface of teeth plays a central part in its treatment. The conventional treatment for periodontal disease fails to remove periodontal infection in a subset of cases, such as those with complicated root morphology. Adjunctive antimicrobial photodynamic therapy (aPDT has been proposed as an additional treatment for this infectious disease. Many periodontal pathogenic bacteria are susceptible to low-power lasers in the presence of dyes, such as methylene blue, toluidine blue O, malachite green, and indocyanine green. aPDT uses these light-activated photosensitizer that is incorporated selectively by bacteria and absorbs a low-power laser/light with an appropriate wavelength to induce singlet oxygen and free radicals, which are toxic to bacteria. While this technique has been evaluated by many clinical studies, some systematic reviews and meta-analyses have reported controversial results about the benefits of aPDT for periodontal treatment. In the light of these previous reports, the aim of this review is to provide comprehensive information about aPDT and help extend knowledge of advanced laser therapy.

  9. pH-stimuli-responsive near-infrared optical imaging nanoprobe based on poly(γ-glutamic acid)/poly(β-amino ester) nanoparticles

    International Nuclear Information System (INIS)

    Park, Hye Sun; Lee, Jung Eun; Cho, Mi Young; Noh, Young-Woock; Lim, Yong Taik; Sung, Moon Hee; Poo, Haryoung; Hong, Kwan Soo

    2011-01-01

    pH-stimuli-responsive near-infrared optical imaging nanoprobes are designed and synthesized in this study in a facile one-step synthesis process based on the use of the biocompatible and biodegradable polymer poly(γ-glutamic acid) (γ-PGA)/poly(β-amino ester) (PBAE). PBAE has good transfection efficiency and promotes degradation properties under acidic conditions. This pH-responsive degradability can be used for the effective release of encapsulating materials after cellular uptake. As an optical imaging probe, indocyanine green (ICG) is an FDA-approved near-infrared fluorescent dye with a quenching property at a high concentration. In this regard, we focus here on the rapid degradation of PBAE in an acidic environment, in which the nanoparticles are disassembled. This allows the ICG dyes to show enhanced fluorescence signals after being releasing from the particles. We demonstrated this principle in cellular uptake experiments. We expect that the developed pH-stimuli-responsive smart nanoprobes can be applied in intracellular delivery signaling applications.

  10. Understanding the three-dimensional anatomy of the superficial lymphatics of the limbs.

    Science.gov (United States)

    Tourani, Saam S; Taylor, G Ian; Ashton, Mark W

    2014-11-01

    There are minimal data in the current literature regarding the depth of the superficial lymphatic collectors of the limbs in relation to the various subcutaneous tissue layers. Injection, microdissection, radiographic, and histologic studies of the superficial lymphatics and the subcutaneous tissues of 32 limbs from 15 human cadavers were performed. Five layers were consistently identified in the integument of all the upper and lower limb specimens: (1) skin, (2) subcutaneous fat, (3) superficial fascia, (4) loose areolar tissue, and (5) deep fascia. Layer 2 was further divided into superficial (2a) and deep (2c) compartments by a thin, transparent, horizontal septum (layer 2b). The main superficial veins and the superficial nerves coursed in layer 4. The lymphatic collectors were found at layer 2c and layer 4. The use of consistent nomenclature to describe the subcutaneous tissue layers facilitates a greater understanding and discussion of the anatomy. In lymphovenous anastomosis for the treatment of lymphedema, indocyanine green lymphography is an unreliable method for identification of the superficial collectors of the thigh. The medial proximal leg, the dorsum of the wrist over the anatomical snuffbox, and the volar proximal forearm provide suitable areas for locating superficial collectors with nearby matching size veins. In vertical medial thigh lift, choosing a dissection plane superficial to the great saphenous vein is unlikely to preserve the collectors of the ventromedial bundle.

  11. Combination therapy of surgical tumor resection with implantation of a hydrogel containing camptothecin-loaded poly(lactic-co-glycolic acid) microspheres in a C6 rat glioma model.

    Science.gov (United States)

    Ozeki, Tetsuya; Kaneko, Daiki; Hashizawa, Kosuke; Imai, Yoshihiro; Tagami, Tatsuaki; Okada, Hiroaki

    2012-01-01

    We have developed a drug-loaded poly(lactic-co-glycolic acid) (PLGA) microsphere-containing thermoreversible gelation polymer (TGP) (drug/PLGA/TGP) formulation as a novel device for implantation after surgical glioma resection. TGP is a thermosensitive polymer that is a gel at body temperature and a sol at room temperature. When a drug/PLGA/TGP formulation is injected into a target site, PLGA microspheres in TGP gel localize at the injection site and do not diffuse across the entire brain tissue, and thus, sustained drug release from the PLGA microspheres at the target site is expected. Using in vivo imaging, we confirmed that the implantation of indocyanine green (ICG)/PLGA/TGP formulation exhibited a stronger localization of ICG at the injection site 28 d after injection compared with that of ICG/PLGA formulation. The therapeutic effect (mean survival) was evaluated in a C6 rat glioma model. Surgical tumor resection alone showed almost no effect on survival (controls, 18 d; surgical resection; 18.5 d). Survival was prolonged after the treatment with a camptothecin (CPT; 10 µg)/PLGA/TGP formulation (24 d). The combination treatment of surgical tumor resection and CPT/PLGA/TGP showed almost the same therapeutic effect (24 d) compared with CPT/PLGA/TGP alone, while the combination treatment produced long term survivors (>60 d). Therefore, the CPT/PLGA/TGP formulation can be an effective candidate for localized and sustained long-term glioma therapy.

  12. Elevated plasma factor VIII enhances venous thrombus formation in rabbits: contribution of factor XI, von Willebrand factor and tissue factor.

    Science.gov (United States)

    Sugita, Chihiro; Yamashita, Atsushi; Matsuura, Yunosuke; Iwakiri, Takashi; Okuyama, Nozomi; Matsuda, Shuntaro; Matsumoto, Tomoko; Inoue, Osamu; Harada, Aya; Kitazawa, Takehisa; Hattori, Kunihiro; Shima, Midori; Asada, Yujiro

    2013-07-01

    Elevated plasma levels of factor VIII (FVIII) are associated with increased risk of deep venous thrombosis. The aim of this study is to elucidate how elevated FVIII levels affect venous thrombus formation and propagation in vivo. We examined rabbit plasma FVIII activity, plasma thrombin generation, whole blood coagulation, platelet aggregation and venous wall thrombogenicity before and one hour after an intravenous infusion of recombinant human FVIII (rFVIII). Venous thrombus induced by the endothelial denudation of rabbit jugular veins was histologically assessed. Thrombus propagation was evaluated as indocyanine green fluorescence intensity. Argatroban, a thrombin inhibitor, and neutralised antibodies for tissue factor (TF), factor XI (FXI), and von Willebrand factor (VWF) were infused before or after thrombus induction to investigate their effects on venous thrombus formation or propagation. Recombinant FVIII (100 IU/kg) increased rabbit plasma FVIII activity two-fold and significantly enhanced whole blood coagulation and total plasma thrombin generation, but did not affect initial thrombin generation time, platelet aggregation and venous wall thrombogenicity. The rFVIII infusion also increased the size of venous thrombus 1 hour after thrombus induction. Argatroban and the antibodies for TF, FXI or VWF inhibited such enhanced thrombus formation and all except TF suppressed thrombus propagation. In conclusion, elevated plasma FVIII levels enhance venous thrombus formation and propagation. Excess thrombin generation by FXI and VWF-mediated FVIII recruitment appear to contribute to the growth of FVIII-driven venous thrombus.

  13. Image navigation as a means to expand the boundaries of fluorescence-guided surgery.

    Science.gov (United States)

    Brouwer, Oscar R; Buckle, Tessa; Bunschoten, Anton; Kuil, Joeri; Vahrmeijer, Alexander L; Wendler, Thomas; Valdés-Olmos, Renato A; van der Poel, Henk G; van Leeuwen, Fijs W B

    2012-05-21

    Hybrid tracers that are both radioactive and fluorescent help extend the use of fluorescence-guided surgery to deeper structures. Such hybrid tracers facilitate preoperative surgical planning using (3D) scintigraphic images and enable synchronous intraoperative radio- and fluorescence guidance. Nevertheless, we previously found that improved orientation during laparoscopic surgery remains desirable. Here we illustrate how intraoperative navigation based on optical tracking of a fluorescence endoscope may help further improve the accuracy of hybrid surgical guidance. After feeding SPECT/CT images with an optical fiducial as a reference target to the navigation system, optical tracking could be used to position the tip of the fluorescence endoscope relative to the preoperative 3D imaging data. This hybrid navigation approach allowed us to accurately identify marker seeds in a phantom setup. The multispectral nature of the fluorescence endoscope enabled stepwise visualization of the two clinically approved fluorescent dyes, fluorescein and indocyanine green. In addition, the approach was used to navigate toward the prostate in a patient undergoing robot-assisted prostatectomy. Navigation of the tracked fluorescence endoscope toward the target identified on SPECT/CT resulted in real-time gradual visualization of the fluorescent signal in the prostate, thus providing an intraoperative confirmation of the navigation accuracy.

  14. HLA-A29-POSITIVE BIRDSHOT CHORIORETINOPATHY IN AN AFRICAN AMERICAN PATIENT.

    Science.gov (United States)

    Knezevic, Alexander; Munk, Marion R; Pappas, Frankie; Merrill, Pauline T; Goldstein, Debra A

    2016-01-01

    To report the first documented case of HLA-A29-positive birdshot chorioretinopathy in an African American patient. A 51-year-old African American woman presented with a 10-year history of photopsia, progressive decrease in visual acuity, metamorphopsia, and new nyctalopia. Both fundi showed evidence of periphlebitis, arterial attenuation, macular edema, and diffuse chorioretinal atrophy. Fluorescein angiography revealed diffuse vascular leakage, and indocyanine green showed evenly distributed and symmetrical hypofluorescent spots, which were difficult to appreciate on fundoscopy. Workup revealed a positive HLA-A29 and was negative for sarcoid, tuberculosis, and syphilis. Birdshot chorioretinopathy overwhelmingly affects non-Hispanic Caucasians, but there have been rare reported cases in other ethnicities including Hispanics and African Americans. This patient's ethnicity may have contributed to the 10-year delay in diagnosis. To our knowledge, this is the first documented HLA-A29 positive case of birdshot chorioretinopathy in an African American. HLA-A29 may be a useful supportive test in cases with classic clinical presentation in non-Caucasian patients to enable the correct diagnose in a timely manner.

  15. Clinical Approach of High Technology Techniques for Control and Elimination of Endodontic Microbiota

    Science.gov (United States)

    Chiniforush, Nasim; Pourhajibagher, Maryam; Shahabi, Sima; Bahador, Abbas

    2015-01-01

    The main goal in endodontic treatment is to eradicate or at least reduce intraradicular microbial population to levels that are more compatible with periapical lesions healing process. Since endodontic infections are polymicrobial in nature, intraradicular survival of endodontic microbiota and their pathogenic properties are influenced by a combination of their virulence factors. The purpose of this article is to review the endodontic microbiota and their respective virulence attributes, as well as perform a literature review of the effects of disinfection procedures in the treatment of endodontic infections to gain best practices. Conventional technique for root canal preparation includes mechanical debridement and application of antimicrobial irrigants. Recently, laser irradiation has been used to enhance the results of root canal treatment through its thermal effect. To reduce thermal side effects, laser activated irrigation (LAI) and photon induced photoacoustic streaming (PIPS) were introduced. Antimicrobial photodynamic therapy (aPDT) by photochemical reaction uses light at a specific wavelength to activate a nontoxic photosensitizer (PS) in the presence of oxygen to produce cytotoxic products. Different PSs are used in dentistry including methylene blue (MB), toluidine blue O (TBO), indocyanine green (ICG) and curcumin. Among different options, ICG could be the best choice due to its peak absorption at wavelength of 808 nm, which coincides with the commercial diode laser devices. Also, this wavelength has more penetration depth compared to other wavelengths used in aPDT. PMID:26705458

  16. In vivo near-infrared dual-axis confocal microendoscopy in the human lower gastrointestinal tract

    Science.gov (United States)

    Piyawattanametha, Wibool; Ra, Hyejun; Qiu, Zhen; Friedland, Shai; Liu, Jonathan T. C.; Loewke, Kevin; Kino, Gordon S.; Solgaard, Olav; Wang, Thomas D.; Mandella, Michael J.; Contag, Christopher H.

    2012-02-01

    Near-infrared confocal microendoscopy is a promising technique for deep in vivo imaging of tissues and can generate high-resolution cross-sectional images at the micron-scale. We demonstrate the use of a dual-axis confocal (DAC) near-infrared fluorescence microendoscope with a 5.5-mm outer diameter for obtaining clinical images of human colorectal mucosa. High-speed two-dimensional en face scanning was achieved through a microelectromechanical systems (MEMS) scanner while a micromotor was used for adjusting the axial focus. In vivo images of human patients are collected at 5 frames/sec with a field of view of 362×212 μm2 and a maximum imaging depth of 140 μm. During routine endoscopy, indocyanine green (ICG) was topically applied a nonspecific optical contrasting agent to regions of the human colon. The DAC microendoscope was then used to obtain microanatomic images of the mucosa by detecting near-infrared fluorescence from ICG. These results suggest that DAC microendoscopy may have utility for visualizing the anatomical and, perhaps, functional changes associated with colorectal pathology for the early detection of colorectal cancer.

  17. Three-dimensional fluorescence lifetime tomography

    International Nuclear Information System (INIS)

    Godavarty, Anuradha; Sevick-Muraca, Eva M.; Eppstein, Margaret J.

    2005-01-01

    Near-infrared fluorescence tomography using molecularly targeted lifetime-sensitive, fluorescent contrast agents have applications for early-stage cancer diagnostics. Yet, although the measurement of fluorescent lifetime imaging microscopy (FLIM) is extensively used in microscopy and spectroscopy applications, demonstration of fluorescence lifetime tomography for medical imaging is limited to two-dimensional studies. Herein, the feasibility of three-dimensional fluorescence-lifetime tomography on clinically relevant phantom volumes is established, using (i) a gain-modulated intensified charge coupled device (CCD) and modulated laser diode imaging system, (ii) two fluorescent contrast agents, e.g., Indocyanine green and 3-3'-Diethylthiatricarbocyanine iodide differing in their fluorescence lifetime by 0.62 ns, and (iii) a two stage approximate extended Kalman filter reconstruction algorithm. Fluorescence measurements of phase and amplitude were acquired on the phantom surface under different target to background fluorescence absorption (70:1, 100:1) and fluorescence lifetime (1:1, 2.1:1) contrasts at target depths of 1.4-2 cm. The Bayesian tomography algorithm was employed to obtain three-dimensional images of lifetime and absorption owing to the fluorophores

  18. A review of performance of near-infrared fluorescence imaging devices used in clinical studies

    Science.gov (United States)

    Zhu, B

    2015-01-01

    Near-infrared fluorescence (NIRF) molecular imaging holds great promise as a new “point-of-care” medical imaging modality that can potentially provide the sensitivity of nuclear medicine techniques, but without the radioactivity that can otherwise place limitations of usage. Recently, NIRF imaging devices of a variety of designs have emerged in the market and in investigational clinical studies using indocyanine green (ICG) as a non-targeting NIRF contrast agent to demark the blood and lymphatic vasculatures both non-invasively and intraoperatively. Approved in the USA since 1956 for intravenous administration, ICG has been more recently used off label in intradermal or subcutaneous administrations for fluorescence imaging of the lymphatic vasculature and lymph nodes. Herein, we summarize the devices of a variety of designs, summarize their performance in lymphatic imaging in a tabular format and comment on necessary efforts to develop standards for device performance to compare and use these emerging devices in future, NIRF molecular imaging studies. PMID:25410320

  19. ICG-fluorescence imaging for detection of peritoneal metastases and residual tumoral scars in locally advanced ovarian cancer: A pilot study.

    Science.gov (United States)

    Veys, Isabelle; Pop, Florin-Catalin; Vankerckhove, Sophie; Barbieux, Romain; Chintinne, Marie; Moreau, Michel; Nogaret, Jean-Marie; Larsimont, Denis; Donckier, Vincent; Bourgeois, Pierre; Liberale, Gabriel

    2018-02-01

    No intraoperative imaging techniques exist for detecting tumor nodules or tumor scar tissues in patients treated with upfront or interval cytoreductive surgery (CS) after neoadjuvant chemotherapy (NAC). The aims of this study were to evaluate the role of indocyanine green (ICG) fluorescence imaging (FI) for the detection of peritoneal metastases (PM) and evaluate whether it can be used to detect remnant tumor cells in scar tissue. Patients with PM from ovarian cancer admitted for CS were included. ICG, at 0.25 mg per kg of patient weight, was injected intraoperatively after explorative laparotomy before CS. A total of 108 peritoneal lesions, including 25 scars, were imaged in 20 patients. Seventy-three were malignant (67.6%) and 35 benign (32.4%). The mean Tumor to Background Ratio (ex vivo) was 1.8 (SD 1.3) in malignant and 1.0 (SD 0.79) in benign nodules (P = 0.007). Of 25 post-NAC scars, the mean Tumor to Background Ratio (TBR) (in vivo) was 2.06 (SD 1.15) in malignant and 1.21 (SD 0.50) in benign nodules (P = 0.26). The positive predictive value of ICG-FI to detect tumor cells in scars was 57.1%. ICG-FI is accurate to demonstrate PM in ovarian cancer but unable to discriminate between benign and malignant post-NAC. © 2017 Wiley Periodicals, Inc.

  20. Nerve fiber layer (NFL) degeneration associated with acute q-switched laser exposure in the nonhuman primate

    Science.gov (United States)

    Zwick, Harry; Zuclich, Joseph A.; Stuck, Bruce E.; Gagliano, Donald A.; Lund, David J.; Glickman, Randolph D.

    1995-01-01

    We have evaluated acute laser retinal exposure in non-human primates using a Rodenstock scanning laser ophthalmoscope (SLO) equipped with spectral imaging laser sources at 488, 514, 633, and 780 nm. Confocal spectral imaging at each laser wavelength allowed evaluation of the image plane from deep within the retinal vascular layer to the more superficial nerve fiber layer in the presence and absence of the short wavelength absorption of the macular pigment. SLO angiography included both fluorescein and indocyanine green procedures to assess the extent of damage to the sensory retina, the retinal pigment epithelium (RPE), and the choroidal vasculature. All laser exposures in this experiment were from a Q-switched Neodymium laser source at an exposure level sufficient to produce vitreous hemorrhage. Confocal imaging of the nerve fiber layer revealed discrete optic nerve sector defects between the lesion site and the macula (retrograde degeneration) as well as between the lesion site and the optic disk (Wallerian degeneration). In multiple hemorrhagic exposures, lesions placed progressively distant from the macula or overlapping the macula formed bridging scars visible at deep retinal levels. Angiography revealed blood flow disturbance at the retina as well as at the choroidal vascular level. These data suggest that acute parafoveal laser retinal injury can involve both direct full thickness damage to the sensory and non-sensory retina and remote nerve fiber degeneration. Such injury has serious functional implications for both central and peripheral visual function.

  1. Technology needs for tomorrow's treatment and diagnosis of macular diseases

    Science.gov (United States)

    Soubrane, Gisèle

    2008-02-01

    Retinal imaging is the basis of macular disease's diagnosis. Currently available technologies in clinical practice are fluorescein and indocyanin green (ICG) angiographies, in addition to optical coherence tomography (OCT), which is an in vivo "histology-like" cross-sectional images of the retina. Recent developments in the field of OCT imaging include Spectral-Domain OCT. However OCT remains a static view of the macula with no direct link with dynamic observation obtained by angiographies. Adaptative optics is an encouraging perspective for fundus analysis in the future, and could be linked to OCT or angiographies. Treatments of macular disease have exploded these past few years. Pharmacologic inhibition of angiogenesis represents a novel approach in the treatment of choroidal neovascularization in eyes with age-related macular degeneration. The major action explored is the direct inhibition of the protein VEGF with antibody-like products. New anti-VEGF drugs are in development aiming at the VEGF receptors or synthesis of VEGF. But various components of the neovascular cascade, including growth factor expression, extracellular matrix modulation, integrin inhibition represent potential targets for modulation with drugs. Intra-vitreal injections are nowadays the main route of administration for these new treatments but they are potentially responsible of side effects such as endophtalmitis. Development of other routes of treatment would require new formulation of used drugs. The improvement of retinal imaging leads to a better understanding of macular disease mechanisms and will help to develop new routes and targets of treatment.

  2. Bevacizumab (Avastin® no tratamento da membrana neovascular coroidal secundária à degeneração macular relacionada à idade: relato de caso Bevacizumab (Avastin® in treatment of choroidal neovascularization secondary to age-related macular degeneration: a case report

    Directory of Open Access Journals (Sweden)

    Tiago Eugênio Faria e Arantes

    2007-12-01

    Full Text Available As drogas anti-angiogênicas foram introduzidas recentemente no arsenal terapêutico das membranas neovasculares coroidais. O objetivo deste relato é descrever um caso de membranas neovasculares coroidais oculta com extenso descolamento do epitélio pigmentado da retina, tratada com bevacizumab (Avastin® intravítrea. A eficácia da medicação foi avaliada por meio da acuidade visual e de exames complementares (angiografia fluoresceínica, videoangiografia com indocianina verde e tomografia de coerência óptica. Após três injeções intravítreas de bevacizumab, obteve-se uma resposta anatômica e visual satisfatória, denotando benefícios da droga, apesar do extenso descolamento do epitélio pigmentado da retina associada a membranas neovasculares coroidais oculta.The antiangiogenic drugs have been recently introduced in the therapeutic armamentarium of choroidal neovascularization. The purpose of this report is to describe a case of occult choroidal neovascularization with extensive retinal pigment epithelial detachment treated with intravitreal bevacizumab (Avastin®. The efficacy of the medication was evaluated by means of visual acuity and complementary exams (fluorescein angiography, indocyanine green video angiography and optical coherence tomography. After three intravitreal injections of bevacizumab a satisfactory anatomic and visual response was achieved, showing benefits of the drug, despite the extensive retinal pigment epithelial detachment associated with occult choroidal neovascularization.

  3. Evaluation of reserved hepatic function in patients with hepatobiliary tumor by 99mTc-GSA. Effect of hyperbilirubinemia and usefulness of regional reserved hepatic functional imaging

    International Nuclear Information System (INIS)

    Jin Wu; Ishikawa, Nobuyoshi; Takeda, Tohoru; Sato, Motohiro; Todoroki, Takeshi; Itai, Yuji; Fukunaga, Kiyoshi; Okumura, Toshiyuki; Hatakeyama, Rokurou.

    1996-01-01

    The evaluation of the reserved hepatic function was performed by 99m Tc-galactosyl serum albumin ( 99m Tc-GSA) in 70 patients with hepatobiliary tumor. The dynamic study was performed to evaluate global reserved hepatic function following the intravenous bolus injection of 99m Tc-GSA, and the hepatic single photon emission computed tomography (SPECT) was obtained to assess the regional reserved hepatic function. The functional hepatic index (LHL 15 ) was derived from liver time-activity data, and it was compared with serum total-bilirubin level, serum albumin level and plasma disappearance rate of indocyanine green (ICG 15 ). In the patients with hepatocellular carcinoma, LHL 15 value agreed well with ICG 15 value, serum total-bilirubin level, and serum albumin level. Moderate or severe hepatic dysfunction was observed at 65.4% of these patients. In the patients with cholangiocellular carcinoma, a discrepancy of LHL 15 value and ICG 15 value was observed. Increment of the ICG 15 value was correlated with that of the serum total-bilirubin level, whereas the correlation was not observed between the LHL 15 value and the serum total-bilirubin level. These results indicate that 99m Tc-GSA scintigraphy can evaluate the reserved hepatic function without the embellishment of jaundice. This method is useful for assessing the global and regional reserved hepatic function. (author)

  4. Optical Coherence Tomography Angiography: Employing a Novel Technique for Investigation in Vogt-Koyanagi-Harada Disease.

    Science.gov (United States)

    Giannakouras, Panagiotis; Andreanos, Konstantinos; Giavi, Barbara; Diagourtas, Andreas

    2017-01-01

    To report a case of Vogt-Koyanagi-Harada (VKH) disease and describe the imaging findings by means of optical coherence tomography angiography (OCTA). Medical and ophthalmological history, ophthalmological examination, laboratory evaluation, B-scan ultrasonography, fluorescein and indocyanine angiography, and optical coherence tomography (OCT) were performed at baseline, as well as OCTA. A 50-year-old healthy female presented with decreased vision in both eyes. A Topcon DRI OCT Triton Plus swept source OCT system was used to visualize and evaluate the retinal and choroidal vascular plexus. Patchy and confluent dark areas in the superficial and deep retinal capillary plexus and choriocapillaris corresponded to areas of hypoperfusion, analyzed as areas of ischemia. VKH disease is characterized by ocular, neurological, and integumentary findings in its complete form. We present a case of incomplete disease in a 50-year-old female evaluated by means of OCTA which is a novel technique that provides depth-resolved images of the retina and choroidal microvasculature without dye injection that allows better visualization and detailed evaluation of the retinal and choroidal vascular plexus.

  5. Optical Coherence Tomography Angiography: Employing a Novel Technique for Investigation in Vogt-Koyanagi-Harada Disease

    Directory of Open Access Journals (Sweden)

    Panagiotis Giannakouras

    2017-07-01

    Full Text Available Purpose: To report a case of Vogt-Koyanagi-Harada (VKH disease and describe the imaging findings by means of optical coherence tomography angiography (OCTA. Methods: Medical and ophthalmological history, ophthalmological examination, laboratory evaluation, B-scan ultrasonography, fluorescein and indocyanine angiography, and optical coherence tomography (OCT were performed at baseline, as well as OCTA. Results: A 50-year-old healthy female presented with decreased vision in both eyes. A Topcon DRI OCT Triton Plus swept source OCT system was used to visualize and evaluate the retinal and choroidal vascular plexus. Patchy and confluent dark areas in the superficial and deep retinal capillary plexus and choriocapillaris corresponded to areas of hypoperfusion, analyzed as areas of ischemia. Conclusions and Importance: VKH disease is characterized by ocular, neurological, and integumentary findings in its complete form. We present a case of incomplete disease in a 50-year-old female evaluated by means of OCTA which is a novel technique that provides depth-resolved images of the retina and choroidal microvasculature without dye injection that allows better visualization and detailed evaluation of the retinal and choroidal vascular plexus.

  6. Validation of curve-fitting method for blood retention of 99mTc-GSA. Comparison with blood sampling method

    International Nuclear Information System (INIS)

    Ha-Kawa, Sang Kil; Suga, Yutaka; Kouda, Katsuyasu; Ikeda, Koshi; Tanaka, Yoshimasa

    1997-01-01

    We investigated a curve-fitting method for the rate of blood retention of 99m Tc-galactosyl serum albumin (GSA) as a substitute for the blood sampling method. Seven healthy volunteers and 27 patients with liver disease underwent 99m Tc-GSA scanning. After normalization of the y-intercept as 100 percent, a biexponential regression curve for the precordial time-activity curve provided the percent injected dose (%ID) of 99m Tc-GSA in the blood without blood sampling. The discrepancy between %ID obtained by the curve-fitting method and that by the multiple blood samples was minimal in normal volunteers 3.1±2.1% (mean±standard deviation, n=77 sampling). Slightly greater discrepancy was observed in patients with liver disease (7.5±6.1%, n=135 sampling). The %ID at 15 min after injection obtained from the fitted curve was significantly greater in patients with liver cirrhosis than in the controls (53.2±11.6%, n=13; vs. 31.9±2.8%, n=7, p 99m Tc-GSA and the plasma retention rate for indocyanine green (r=-0.869, p 99m Tc-GSA and could be a substitute for the blood sampling method. (author)

  7. Ablation of intervertebral discs in dogs using a MicroJet-assisted dye-enhanced injection device coupled with the diode laser

    Science.gov (United States)

    Bartels, Kenneth E.; Henry, George A.; Dickey, D. Thomas; Stair, Ernest L.; Powell, Ronald; Schafer, Steven A.; Nordquist, Robert E.; Frederickson, Christopher J.; Hayes, Donald J.; Wallace, David B.

    1998-07-01

    Use of holmium laser energy for vaporization/coagulation of the nucleus pulposus in canine intervertebral discs has been previously reported and is currently being applied clinically in veterinary medicine. The procedure was originally developed in the canine model and intended for potential human use. Since the pulsed (15 Hz) holmium laser energy exerts photomechanical and photothermal effects, the potential for extrusion of additional disc material to the detriment of the patient is possible using the procedure developed for the dog. To reduce this potential complication, use of diode laser (805 nm - CW mode) energy, coupled with indocyanine green (ICG) as a selective laser energy absorber, was formulated as a possible alternative. Delivery of the ICG and diode laser energy was through a MicroJet device that could dispense dye interactively between individual laser 'shots.' Results have shown that it is possible to selectively ablate nucleus pulposus in the canine model using the device described. Acute observations (gross and histopathologic) illustrate that accurate placement of the spinal needle before introduction of the MicroJet device is critically dependent on the expertise of the interventional radiologist. In addition, the success of the overall technique depends on consistent delivery of both ICG and diode laser energy. Minimizing tissue carbonization on the tip of the MicroJet device is also of crucial importance for effective application of the technique in clinical veterinary medicine.

  8. Clinical trial of pin-point photodynamic therapy using an optic fiber for the improvement of enlarged facial pores: a case study.

    Science.gov (United States)

    Kim, Sangeun; Cho, Kyeong-Hun

    2009-01-01

    There are few publications on the treatment options for facial pore size reduction. A focused therapy is needed. To evaluate the efficacy of selective photodynamic therapy (PDT) using an optic fiber for the size reduction of large facial pores. A series of five patients (skin phototypes IV-V) with large facial pores received two successive weekly treatments with an 810-nm diode laser using a fine optic fiber after indocyanine green (ICG) was applied selectively to enlarged pores. Patients were evaluated using digital photography at each treatment session, and at 3 months post-operation. Clinical assessment scores were determined at each treatment session and follow-up visit. Patient satisfaction surveys were obtained at the end of the study. All five participants who completed the 3-month follow-up gave a subjective assessment of reduction of facial pore size. Modest to excellent improvement was achieved. This study demonstrates that treatment with pin-point PDT using an optic fiber is a well-tolerated and effective regimen for the reduction of facial pore size.

  9. [Krypton laser photocoagulation at low power setting for age-related macular degeneration complicated with subfoveal choroidal neovascularization].

    Science.gov (United States)

    Zhang, Cheng-fen; Jia, Yan; Li, Zhi-qing; Du, Hong; Han, Bao-ling

    2004-12-01

    To evaluate the efficacy of krypton laser photocoagulation for treatment of age-related macular degeneration (AMD) complicated with mainly subfoveal classic choroidal neovascularization (CNV). Seventeen eyes of 17 cases, aged 50 - 74 years (averaged 60.8 years) with mainly subfoveal classic choroidal neovascularization were treated with krypton laser at lower power setting. The treatment was completed in one session. Another course of treatment was given 4 weeks later if there was active leakage demonstrated at the CNV area. Visual acuity, anterior segment and fundus examination, perimetry test, fundus fluorescein angiography (FFA) and indocyanine green angiography (ICGA) were performed before and after treatment. The follow-up period was 3.5 years on average (1 - 8 years). There was no immediately decrease of visual acuity after treatment. All treated eyes showed absorption of hemorrhages and/or exudates and diminished leakages. Visual acuity was stable in 8 eyes; improved in 6 eyes (>/= 2 lines), and decreased in 3 eyes (Krypton laser photocoagulation at low power setting is an effective treatment for AMD with mainly classic subfoveal choroidal neovascularization.

  10. Multimodal imaging findings in 'hyper-early' stage MEWDS.

    Science.gov (United States)

    Cahuzac, Armelle; Wolff, Benjamin; Mathis, Thibaud; Errera, Marie-Hélène; Sahel, José-Alain; Mauget-Faÿsse, Martine

    2017-10-01

    To describe a new stage of multiple evanescent white dot syndrome (MEWDS), occurring at a very early phase of the disease. Retrospective analysis of clinical, angiographic and tomographic findings in four patients with 'hyper-early' stage MEWDS. In four patients seen within 1 week of the onset of symptoms, fundus analysis revealed macular granity and the classic yellow-white dots, some having no corresponding hyperautofluorescent pattern. Spectral-domain optical coherence tomography (SD-OCT) showed central foveal disruption of the ellipsoid zone (EZ) and interdigitation layer with a hyper-reflective dome-shaped lesion. In two patients, fluorescein angiography (FA) revealed an intermediate hypofluorescent perimacular halo, whereas late indocyanine green angiography (ICGA) showed a hyperfluorescent halo as well as the classic MEWDS features. After a few days, the EZ disruption appeared complete on OCT and fundus autofluorescence (FAF) in all patients. Visual acuity, OCT and FAF findings had fully recovered within 3 months. We have shown a new feature of MEWDS on FAF, OCT, FA and ICGA, corresponding to a very early stage of the disease. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Xenotransplantation of neonatal porcine liver cells.

    Science.gov (United States)

    Garkavenko, O; Emerich, D F; Muzina, M; Muzina, Z; Vasconcellos, A V; Ferguson, A B; Cooper, I J; Elliott, R B

    2005-01-01

    Xenotransplantation of porcine liver cell types may provide a means of overcoming the shortage of suitable donor tissues to treat hepatic diseases characterized by inherited inborn errors of metabolism or protein production. Here we report the successful isolation, culture, and xenotransplantation of liver cells harvested from 7- to 10-day-old piglets. Liver cells were isolated and cultured immediately after harvesting. Cell viability was excellent (>90%) over the duration of the in vitro studies (3 weeks) and the cultured cells continued to significantly proliferate. These cells also retained their normal secretory and metabolic capabilities as determined by continued release of albumin, factor 8, and indocyanin green (ICG) uptake. After 3 weeks in culture, porcine liver cells were loaded into immunoisolatory macro devices (Theracyte devices) and placed into the intraperitoneal cavity of immunocompetant CD1 mice. Eight weeks later, the devices were retrieved and the cells analyzed for posttransplant determinations of survival and function. Post mortem analysis confirmed that the cell-loaded devices were biocompatible, and were well-tolerated without inducing any notable inflammatory reaction in the tissues immediately surrounding the encapsulated cells. Finally, the encapsulated liver cells remained viable and functional as determined by histologic analyses and ICG uptake/release. The successful harvesting, culturing, and xenotransplantation of functional neonatal pig liver cells support the continued development of this approach for treating a range of currently undertreated or intractable hepatic diseases.

  12. Characteristic appearances of fundus autofluorescence in treatment-naive and active polypoidal choroidal vasculopathy: a retrospective study of 170 patients.

    Science.gov (United States)

    Zhao, Xinyu; Xia, Song; Chen, Youxin

    2018-06-01

    To investigate the characteristic appearances of fundus autofluorescence (FAF) in patients with treatment-naive and active polypoidal choroidal vasculopathy (PCV). Cases with the diagnosis of treatment-naive and active PCV from November 2012 to May 2017 at Peking Union Medical College Hospital were retrospectively reviewed. All patients underwent comprehensive ophthalmologic examination. Autofluorescence (AF) findings were described at the retinal sites of the corresponding lesions identified and diagnosed using indocyanine green angiography and spectral-domain optical coherence tomography. One hundred seventy patients with 192 affected eyes were included. The logMAR BCVA of the patients were 0.53 ± 0.28. The six AF patterns of 243 polypoidal lesions were confluent hypo-AF with hyper-AF ring (49.8%), confluent hypo-AF (22.6%), hyper-AF with hypo-AF ring (3.7%), granular hypo-AF (7.0%), blocked hypo-AF due to hemorrhage (8.6%), and polyps without apparent AF changes (8.2%). For 146 branching vascular networks (BVNs), 97.3% were granular hypo-AF, and others were blocked hypo-AF due to hemorrhage. In eyes with treatment-naive and active PCV, the polypoidal lesions and BVNs induce characteristic FAF changes. FAF images provide reliable adjunct reference for the diagnosis of PCV.

  13. Challenges and advantages in wide-field optical coherence tomography angiography imaging of the human retinal and choroidal vasculature at 1.7-MHz A-scan rate

    Science.gov (United States)

    Poddar, Raju; Migacz, Justin V.; Schwartz, Daniel M.; Werner, John S.; Gorczynska, Iwona

    2017-10-01

    We present noninvasive, three-dimensional, depth-resolved imaging of human retinal and choroidal blood circulation with a swept-source optical coherence tomography (OCT) system at 1065-nm center wavelength. Motion contrast OCT imaging was performed with the phase-variance OCT angiography method. A Fourier-domain mode-locked light source was used to enable an imaging rate of 1.7 MHz. We experimentally demonstrate the challenges and advantages of wide-field OCT angiography (OCTA). In the discussion, we consider acquisition time, scanning area, scanning density, and their influence on visualization of selected features of the retinal and choroidal vascular networks. The OCTA imaging was performed with a field of view of 16 deg (5 mm×5 mm) and 30 deg (9 mm×9 mm). Data were presented in en face projections generated from single volumes and in en face projection mosaics generated from up to 4 datasets. OCTA imaging at 1.7 MHz A-scan rate was compared with results obtained from a commercial OCTA instrument and with conventional ophthalmic diagnostic methods: fundus photography, fluorescein, and indocyanine green angiography. Comparison of images obtained from all methods is demonstrated using the same eye of a healthy volunteer. For example, imaging of retinal pathology is presented in three cases of advanced age-related macular degeneration.

  14. Optical Coherence Tomography Angiography in Retinal Vascular Diseases and Choroidal Neovascularization

    Directory of Open Access Journals (Sweden)

    Rodolfo Mastropasqua

    2015-01-01

    Full Text Available Purpose. To assess the ability of optical coherence tomography-angiography (OCT-A to show and analyze retinal vascular patterns and the choroidal neovascularization (CNV in retinal vascular diseases. Methods. Seven eyes of seven consecutive patients with retinal vascular diseases were examined. Two healthy subjects served as controls. All eyes were scanned with the SD-OCT XR Avanti (Optovue Inc, Fremont CA, USA. Split spectrum amplitude decorrelation angiography algorithm was used to identify the blood flow within the tissue. Fluorescein angiography (FA and indocyanine green angiography (ICGA with Spectralis HRA + OCT (Heidelberg Engineering GmbH were performed. Results. In healthy subjects OCT-A visualized major macular vessels and detailed capillary networks around the foveal avascular zone. Patients were affected with myopic CNV (2 eyes, age-related macular degeneration related (2, branch retinal vein occlusion (BRVO (2, and branch retinal artery occlusion (BRAO (1. OCT-A images provided distinct vascular patterns, distinguishing perfused and nonperfused areas in BRVO and BRAO and recognizing the presence, location, and size of CNV. Conclusions. OCT-A provides detailed images of retinal vascular plexuses and quantitative data of pathologic structures. Further studies are warranted to define the role of OCT-A in the assessment of retinovascular diseases, with respect to conventional FA and ICG-A.

  15. Laser Soldering of Rat Skin Using a Controlled Feedback System

    Directory of Open Access Journals (Sweden)

    Mohammad Sadegh Nourbakhsh

    2009-03-01

    Full Text Available Introduction: Laser tissue soldering using albumin and indocyanine green dye (ICG is an effective technique utilized in various surgical procedures. The purpose of this study was to perform laser soldering of rat skin under a feedback control system and compare the results with those obtained using standard sutures. Material and Methods: Skin incisions were made over eight rats’ dorsa, which were subsequently closed using different wound closure interventions in two groups: (a using a temperature controlled infrared detector or (b by suture. Tensile strengths were measured at 2, 5, 7 and 10 days post-incision. Histological examination was performed at the time of sacrifice. Results: Tensile strength results showed that during the initial days following the incisions, the tensile strengths of the sutured samples were greater than the laser samples. However, 10 days after the incisions, the tensile strengths of the laser soldered incisions were higher than the sutured cuts. Histopathological examination showed a preferred wound healing response in the soldered skin compared with the control samples. The healing indices of the laser soldered repairs (426 were significantly better than the control samples (340.5. Conclusion: Tissue feedback control of temperature and optical changes in laser soldering of skin leads to a higher tensile strength and better histological results and hence this method may be considered as an alternative to standard suturing.

  16. Thermographic analysis of photodynamic therapy with intense pulsed light and needle-free injection photosensitizer delivery: an animal study

    Science.gov (United States)

    Requena, Michelle B.; Stringasci, Mirian D.; Pratavieira, Sebastião.; Vollet-Filho, José Dirceu; de Nardi, Andrigo B.; Escobar, Andre; da Rocha, Rozana W.; Bagnato, Vanderlei S.; de Menezes, Priscila F. C.

    2018-02-01

    The photodynamic therapy (PDT) is a therapeutic modality that depends mostly on photosensitizer (PS), light and molecular oxygen species. However, there are still technical limitations in clinical PDT that are under constant development, particularly concerning PS and light delivery. Intense Pulsed Light (IPL) sources are systems able to generate pulses of high energy with polychromatic light. IPL is a technique mainly used in the cosmetic area to perform various skin treatments for therapeutic and aesthetic applications. The goals of this study were to determine temperature variance during the application of IPL in porcine skin model, and the PDT effects using this light source with PS delivery by a commercial high pressure, needle-free injection system. The PSs tested were Indocyanine Green (ICG) and Photodithazine (PDZ), and the results showed an increase bellow 10 °C in the skin surface using a thermographic camera to measure. In conclusion, our preliminary study demonstrated that IPL associated with needle-free injection PS delivery could be a promising alternative to PDT.

  17. Magnetic Enrichment of Dendritic Cell Vaccine in Lymph Node with Fluorescent-Magnetic Nanoparticles Enhanced Cancer Immunotherapy

    Science.gov (United States)

    Jin, Honglin; Qian, Yuan; Dai, Yanfeng; Qiao, Sha; Huang, Chuan; Lu, Lisen; Luo, Qingming; Chen, Jing; Zhang, Zhihong

    2016-01-01

    Dendritic cell (DC) migration to the lymph node is a key component of DC-based immunotherapy. However, the DC homing rate to the lymphoid tissues is poor, thus hindering the DC-mediated activation of antigen-specific T cells. Here, we developed a system using fluorescent magnetic nanoparticles (α-AP-fmNPs; loaded with antigen peptide, iron oxide nanoparticles, and indocyanine green) in combination with magnetic pull force (MPF) to successfully manipulate DC migration in vitro and in vivo. α-AP-fmNPs endowed DCs with MPF-responsiveness, antigen presentation, and simultaneous optical and magnetic resonance imaging detectability. We showed for the first time that α-AP-fmNP-loaded DCs were sensitive to MPF, and their migration efficiency could be dramatically improved both in vitro and in vivo through MPF treatment. Due to the enhanced migration of DCs, MPF treatment significantly augmented antitumor efficacy of the nanoparticle-loaded DCs. Therefore, we have developed a biocompatible approach with which to improve the homing efficiency of DCs and subsequent anti-tumor efficacy, and track their migration by multi-modality imaging, with great potential applications for DC-based cancer immunotherapy. PMID:27698936

  18. Effect of Qi Ming Granule on the choroidal circulation in diabetic patients

    Directory of Open Access Journals (Sweden)

    Ke-Jun Li

    2016-03-01

    Full Text Available AIM:To investigate the effect of a Chinese medicine(Qi Ming granuleon the retinal and choroidal circulation in diabetes patients. METHODS: According to the results of fundus fluorescein angiography(FFA, all the 45 diabetes patients were divided into no diabetic retinopathy(NDRgroup and nonproliferative diabetic retinopathy(NPDRgroup. All subjects were examined by FFA and indocyanine green angiography(ICGAat the same time. After taken Qi Ming granule for 3mo, all subjects were examined by the same method. FFA and ICGA were used to evaluate the retinal and choroidal circulation and their features. The key points were filling time for the retinal and choroidal circulation before and after treatments. The accuracy data was used to evaluate the effect.RESULTS: After taken Qi Ming granule for 3mo, there were significant decrease of the retina and the choroid filling time in NDR and NPDR groups. The occurrence rate of various abnormal angiographic features were significantly decreased. CONCLUSION: Qi Ming granule can accelerate the blood flow of retina and choroid, improve the blood circulation in diabetes patients, and delay the occurrence and development of diabetic retinopathy.

  19. Noninvasive measurement of cardiopulmonary blood volume: evaluation of the centroid method

    International Nuclear Information System (INIS)

    Fouad, F.M.; MacIntyre, W.J.; Tarazi, R.C.

    1981-01-01

    Cardiopulmonary blood volume (CPV) and mean pulmonary transit time (MTT) determined by radionuclide measurements (Tc-99m HSA) were compared with values obtained from simultaneous dye-dilution (DD) studies (indocyanine green). The mean transit time was obtained from radionuclide curves by two methods: the peak-to-peak time and the interval between the two centroids determined from the right and left-ventricular time-concentration curves. Correlation of dye-dilution MTT and peak-to-peak time was significant (r = 0.79, p < 0.001), but its correlation with centroid-derived values was better (r = 0.86, p < 0.001). CPV values (using the centroid method for radionuclide technique) correlated significantly with values derived from dye-dilution curves (r = 0.74, p < 0.001). Discrepancies between the two were greater the more rapid the circulation (r = 0.61, p < 0.01), suggesting that minor inaccuracies of dye-dilution methods, due to positioning or delay of the system, can become magnified in hyperkinetic conditions. The radionuclide method is simple, repeatable, and noninvasive, and it provides simultaneous evaluation of pulmonary and systemic hemodynamics. Further, calculation of the ratio of cardiopulmonary to total blood volume can be used as an index of overall venous distensibility and relocation of intravascular blood volume

  20. Time reversal optical tomography locates fluorescent targets in a turbid medium

    Science.gov (United States)

    Wu, Binlin; Cai, W.; Gayen, S. K.

    2013-03-01

    A fluorescence optical tomography approach that extends time reversal optical tomography (TROT) to locate fluorescent targets embedded in a turbid medium is introduced. It uses a multi-source illumination and multi-detector signal acquisition scheme, along with TR matrix formalism, and multiple signal classification (MUSIC) to construct pseudo-image of the targets. The samples consisted of a single or two small tubes filled with water solution of Indocyanine Green (ICG) dye as targets embedded in a 250 mm × 250 mm × 60 mm rectangular cell filled with Intralipid-20% suspension as the scattering medium. The ICG concentration was 1μM, and the Intralipid-20% concentration was adjusted to provide ~ 1-mm transport length for both excitation wavelength of 790 nm and fluorescence wavelength around 825 nm. The data matrix was constructed using the diffusely transmitted fluorescence signals for all scan positions, and the TR matrix was constructed by multiplying data matrix with its transpose. A pseudo spectrum was calculated using the signal subspace of the TR matrix. Tomographic images were generated using the pseudo spectrum. The peaks in the pseudo images provided locations of the target(s) with sub-millimeter accuracy. Concurrent transmission TROT measurements corroborated fluorescence-TROT findings. The results demonstrate that TROT is a fast approach that can be used to obtain accurate three-dimensional position information of fluorescence targets embedded deep inside a highly scattering medium, such as, a contrast-enhanced tumor in a human breast.

  1. Considering photodynamic therapy as a therapeutic modality in selected cases of dome-shaped macula complicated by foveal serous retinal detachment.

    Science.gov (United States)

    Arapi, Ilir; Neri, Piergiorgio; Mariotti, Cesare; Gesuita, Rosaria; Pirani, Vittorio; Freddo, Francesco; Lutaj, Pajtim; Giovannini, Alfonso

    2015-02-01

    To study the role of photodynamic therapy (PDT) as a therapeutic modality in myopic patients with dome-shaped macula (DSM) associated with foveal serous retinal detachment (SRD). Retrospective interventional case series. The medical records of 10 consecutive myopic patients (10 eyes) with DSM associated with subfoveal SRD and treated with PDT were reviewed. Visual gain and loss were considered as increasing or decreasing of two or more lines of best corrected visual acuity (BCVA), respectively, and eyes with fluid resolution were deemed responsive to PDT. All eyes underwent several PDT treatments, with a median of three and a median follow-up time of 15.5 months. At final follow-up, six eyes (60%) showed complete resolution of the foveal SRD. The baseline hypocyanescent macular area observed during late indocyanine green angiography (ICGA) frames was significantly lower in the group of patients who responded to PDT and had an increase of at least two Snellen lines in BCVA (P = .01). Data suggest that myopic eyes associated with DSM and foveal SRD may be responsive to PDT, showing total resolution of fluid accumulation and positive BCVA changes if baseline ICGA findings show evidence of a limited hypocyanescent macular area. Copyright 2015, SLACK Incorporated.

  2. Herniation of the retina in the central macula in an adult after iridocyclitis.

    Science.gov (United States)

    Guo, Qing; Pi, Yuli; Gao, Ting

    2014-09-01

    To report an unusual case of retinal hernia in the central macula in an adult after iridocyclitis. We report a case of a 46-year-old male who presented with blurred vision 2 weeks after complete resolution of acute iridocyclitis. Anterior segment and vitreous body examinations were unremarkable. Yellowish spots in the macular area were observed. Spectral domain optical coherence tomography (SD-OCT) imaging of the macula showed loss of the inner segment/outer segment (IS/OS) photoreceptor junction, with irregularity of the retinal pigment epithelium (RPE), and a V-shaped hernia of the retina into the choroid. The macular lesions emerged as mild window defects on fluorescein angiography and were visualized as hypofluorescent patches on all-phase indocyanine green angiography. At a one month follow-up, the best-corrected visual acuity improved to 20/20, which was followed by partial restoration of the IS/OS line, but a V-shaped hernia of the retina remained unchanged on SD-OCT. Ophthalmologists should be alert to the changes in OCT of the macula in patients after iridocyclitis and further research on the cause and possible predisposing factors for retinal herniation is warranted.

  3. Choroidal findings in dome-shaped macula in highly myopic eyes: a longitudinal study.

    Science.gov (United States)

    Viola, Francesco; Dell'Arti, Laura; Benatti, Eleonora; Invernizzi, Alessandro; Mapelli, Chiara; Ferrari, Fabio; Ratiglia, Roberto; Staurenghi, Giovanni; Barteselli, Giulio

    2015-01-01

    To describe choroidal findings in dome-shaped macula associated with high myopia using fluorescein angiography (FA), indocyanine green angiography (ICGA), and spectral-domain optical coherence tomography (SD OCT), and to elucidate the mechanism and natural course of serous retinal detachment (RD) associated with dome-shaped macula. Retrospective, observational case series. We reviewed longitudinal imaging results of 52 highly myopic eyes with dome-shaped macula. Changes on FA and ICGA were assessed. Retinal, choroidal, and scleral thicknesses and bulge height were measured on SD OCT. Serous RD was the most common abnormality associated with dome-shaped macula, detected by SD OCT in 44% of the cases with no associated choroidal neovascularization. Significant differences in the proportion of eyes with pinpoint leakage on FA (P macula was likely caused by choroidal vascular changes, similar to central serous chorioretinopathy, but specifically confined in the inward bulge of the staphyloma and secondary to excessive scleral thickening. Serous retinal detachment showed fluctuating changes over time, with alternating active and inactive stages. Angiographic findings in dome-shaped macula suggest the choroid as a target for possible treatment strategies. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. The combination design for open and endoscopic surgery using fluorescence molecular imaging technology

    Science.gov (United States)

    Mao, Yamin; Jiang, Shixin; Ye, Jinzuo; An, Yu; Yang, Xin; Chi, Chongwei; Tian, Jie

    2015-03-01

    For clinical surgery, it is still a challenge to objectively determine tumor margins during surgery. With the development of medical imaging technology, fluorescence molecular imaging (FMI) method can provide real-time intraoperative tumor margin information. Furthermore, surgical navigation system based on FMI technology plays an important role for the aid of surgeons' precise tumor margin decision. However, detection depth is the most limitation exists in the FMI technique and the method convenient for either macro superficial detection or micro deep tissue detection is needed. In this study, we combined advantages of both open surgery and endoscopic imaging systems with FMI technology. Indocyanine green (ICG) experiments were performed to confirm the feasibility of fluorescence detection in our system. Then, the ICG signal was photographed in the detection area with our system. When the system connected with endoscope lens, the minimum quantity of ICG detected by our system was 0.195 ug. For aspect of C mount lens, the sensitivity of ICG detection with our system was 0.195ug. Our experiments results proved that it was feasible to detect fluorescence images with this combination method. Our system shows great potential in the clinical applications of precise dissection of various tumors

  5. Novel techniques of real-time blood flow and functional mapping: technical note.

    Science.gov (United States)

    Kamada, Kyousuke; Ogawa, Hiroshi; Saito, Masato; Tamura, Yukie; Anei, Ryogo; Kapeller, Christoph; Hayashi, Hideaki; Prueckl, Robert; Guger, Christoph

    2014-01-01

    There are two main approaches to intraoperative monitoring in neurosurgery. One approach is related to fluorescent phenomena and the other is related to oscillatory neuronal activity. We developed novel techniques to visualize blood flow (BF) conditions in real time, based on indocyanine green videography (ICG-VG) and the electrophysiological phenomenon of high gamma activity (HGA). We investigated the use of ICG-VG in four patients with moyamoya disease and two with arteriovenous malformation (AVM), and we investigated the use of real-time HGA mapping in four patients with brain tumors who underwent lesion resection with awake craniotomy. Real-time data processing of ICG-VG was based on perfusion imaging, which generated parameters including arrival time (AT), mean transit time (MTT), and BF of brain surface vessels. During awake craniotomy, we analyzed the frequency components of brain oscillation and performed real-time HGA mapping to identify functional areas. Processed results were projected on a wireless monitor linked to the operating microscope. After revascularization for moyamoya disease, AT and BF were significantly shortened and increased, respectively, suggesting hyperperfusion. Real-time fusion images on the wireless monitor provided anatomical, BF, and functional information simultaneously, and allowed the resection of AVMs under the microscope. Real-time HGA mapping during awake craniotomy rapidly indicated the eloquent areas of motor and language function and significantly shortened the operation time. These novel techniques, which we introduced might improve the reliability of intraoperative monitoring and enable the development of rational and objective surgical strategies.

  6. Factors influencing liver and spleen volume changes after donor hepatectomy for living donor liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Ji Hee; Ryeom, Hunku; Song, Jung Hup [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2013-11-15

    To define the changes in liver and spleen volumes in the early postoperative period after partial liver donation for living-donor liver transplantation (LDLT) and to determine factors that influence liver and spleen volume changes. 27 donors who underwent partial hepatectomy for LDLT were included in this study. The rates of liver and spleen volume change, measured with CT volumetry, were correlated with several factors. The analyzed factors included the indocyanine green (ICG) retention rate at 15 minutes after ICG administration, preoperative platelet count, preoperative liver and splenic volumes, resected liver volume, resected-to-whole liver volume ratio (LV{sub R}/LV{sub W}), resected liver volume to the sum of whole liver and spleen volume ratio [LV{sub R}/(LV{sub W} + SV{sub 0})], and pre and post hepatectomy portal venous pressures. In all hepatectomy donors, the volumes of the remnant liver and spleen were increased (increased rates, 59.5 ± 50.5%, 47.9 ± 22.6%). The increment rate of the remnant liver volume revealed a positive correlation with LV{sub R}/LV{sub W} (r = 0.759, p < 0.01). The other analyzed factors showed no correlation with changes in liver and spleen volumes. The spleen and remnant liver volumes were increased at CT volumetry performed 2 weeks after partial liver donation. Among the various analyzed factors, LV{sub R}/LV{sub W} influences the increment rate of the remnant liver volume.

  7. Factors influencing liver and spleen volume changes after donor hepatectomy for living donor liver transplantation

    International Nuclear Information System (INIS)

    Bae, Ji Hee; Ryeom, Hunku; Song, Jung Hup

    2013-01-01

    To define the changes in liver and spleen volumes in the early postoperative period after partial liver donation for living-donor liver transplantation (LDLT) and to determine factors that influence liver and spleen volume changes. 27 donors who underwent partial hepatectomy for LDLT were included in this study. The rates of liver and spleen volume change, measured with CT volumetry, were correlated with several factors. The analyzed factors included the indocyanine green (ICG) retention rate at 15 minutes after ICG administration, preoperative platelet count, preoperative liver and splenic volumes, resected liver volume, resected-to-whole liver volume ratio (LV R /LV W ), resected liver volume to the sum of whole liver and spleen volume ratio [LV R /(LV W + SV 0 )], and pre and post hepatectomy portal venous pressures. In all hepatectomy donors, the volumes of the remnant liver and spleen were increased (increased rates, 59.5 ± 50.5%, 47.9 ± 22.6%). The increment rate of the remnant liver volume revealed a positive correlation with LV R /LV W (r = 0.759, p R /LV W influences the increment rate of the remnant liver volume.

  8. Pachychoroid neovasculopathy in extramacular choroidal neovascularization

    Directory of Open Access Journals (Sweden)

    Gupta MP

    2016-07-01

    Full Text Available Mrinali Patel Gupta, Irene Rusu, Carly Seidman, Anton Orlin, Donald J D’Amico, Szilard Kiss Department of Ophthalmology, Weill Cornell Medicine, New York-Presbyterian Hospital, New York, NY, USA Purpose: To review a series of extramacular choroidal neovascular membranes (CNVMs in the context of their choroidal features, as determined by optical coherence tomography (OCT.Methods: Patients with extramacular CNVMs were identified from a tertiary care center through a review of records. The charts and cases were reviewed using multimodal imaging including fundus photography, OCT, fluorescein angiography (FA, and indocyanine angio­graphy (ICG.Results: Of six patients with extramacular CNVMs evaluated in this series, four patients (66.7% exhibited pachychoroidopathy on OCT imaging under or adjacent to the extramacular CNVM. All four of these patients also exhibited pachychoroidopathy in the macular OCT distant from the CNVM.Conclusion: Pachychoroidopathy is implicated in some cases of extramacular CNVMs. This represents the first report, to our knowledge, of pachychoroidopathy in extramacular CNVM. Keywords: choroidal neovascularization, pachychoroidopathy, pachychoroid neovasculopathy, peripheral disciform lesions, extramacular choroidal neovascularization, polypoidal choroidal vasculopathy

  9. Retinal pigment epithelial detachments and tears, and progressive retinal degeneration in light chain deposition disease.

    Science.gov (United States)

    Spielberg, Leigh H; Heckenlively, John R; Leys, Anita M

    2013-05-01

    Light-chain deposition disease (LCDD) is a rare condition characterised by deposition of monoclonal immunoglobulin light chains (LCs) in tissues, resulting in varying degrees of organ dysfunction. This study reports the characteristic clinical ocular findings seen in advanced LCDD upon development of ocular fundus changes. This is the first report to describe this entity in vivo in a series of patients. A case series of ocular fundus changes in three patients with kidney biopsy-proven LCDD. All patients underwent best corrected visual acuity (BCVA) exam, perimetry, colour fundus photography and fluorescein angiography; two patients underwent indocyanine green angiography, optical coherence tomography, ultrasound and electroretinography; and one patient underwent fundus autofluorescence. Three patients, 53-60 years old at initial presentation, were studied. All three presented with night blindness, poor dark adaptation, metamorphopsia and visual loss. Examination revealed serous and serohaemorrhagic detachments, multiple retinal pigment epithelial (RPE) tears, diffuse RPE degeneration and progressive fibrotic changes. Neither choroidal neovascularisation nor other vascular abnormalities were present. Final best corrected visual acuity (BCVA) ranged from 20/40 to 20/300. Progressive LC deposition in the fundus seems to damage RPE pump function with flow disturbance between choroid and retina. This pathogenesis can explain the evolution to RPE detachments and subsequent rips and progressive retinal malfunction.

  10. Multimodal scanning laser ophthalmoscopy for image guided treatment of age-related macular degeneration

    Science.gov (United States)

    Hammer, Daniel X.; Ferguson, R. D.; Patel, Ankit H.; Iftimia, Nicusor V.; Mujat, Mircea; Husain, Deeba

    2009-02-01

    Subretinal neovascular membranes (SRNM) are a deleterious complication of laser eye injury and retinal diseases such as age-related macular degeneration (AMD), choroiditis, and myopic retinopathy. Photodynamic therapy (PDT) and anti-vascular endothelial growth factor (VEGF) drugs are approved treatment methods. PDT acts by selective dye accumulation, activation by laser light, and disruption and clotting of the new leaky vessels. However, PDT surgery is currently not image-guided, nor does it proceed in an efficient or automated manner. This may contribute to the high rate of re-treatment. We have developed a multimodal scanning laser ophthalmoscope (SLO) for automated diagnosis and image-guided treatment of SRNMs associated with AMD. The system combines line scanning laser ophthalmoscopy (LSLO), fluorescein angiography (FA), indocyanine green angiography (ICGA), PDT laser delivery, and retinal tracking in a compact, efficient platform. This paper describes the system hardware and software design, performance characterization, and automated patient imaging and treatment session procedures and algorithms. Also, we present initial imaging and tracking measurements on normal subjects and automated lesion demarcation and sizing analysis of previously acquired angiograms. Future pre-clinical testing includes line scanning angiography and PDT treatment of AMD subjects. The automated acquisition procedure, enhanced and expedited data post-processing, and innovative image visualization and interpretation tools provided by the multimodal retinal imager may eventually aid in the diagnosis, treatment, and prognosis of AMD and other retinal diseases.

  11. Improved hepatocyte function of future liver remnant of cirrhotic rats after portal vein ligation: a bonus other than volume shifting.

    Science.gov (United States)

    Lin, Kun-Ju; Liao, Chien-Hung; Hsiao, Ing-Tsung; Yen, Tzu-Chen; Chen, Tse-Ching; Jan, Yi-Yin; Chen, Miin-Fu; Yeh, Ta-Sen

    2009-02-01

    Preoperative portal vein embolization is increasingly employed for those with hepatocellular carcinoma and cirrhosis to gain a volume-shifting effect. However, the alterations of histologic architecture and hepatocyte function of future liver remnant (FLR) remain unexplored. Portal vein ligation (PVL) was performed in cirrhotic and noncirrhotic rats. Regeneration indices that include the DNA synthesis index, restituted liver mass, and the redistributed volume ratio were measured. The indocyanine green 15' retention test (ICG-R15), histologic changes, total Knodell score, and activated hepatic stellate cells (HSCs) were measured before and after PVL. Tc-99m sulfur-colloid liver single photon emission computed tomography (SPECT) and diisopropyl iminoacetic acid (DISIDA) SPECT were conducted. The redistributed volume ratio of cirrhotic rats was less than noncirrhotic rats (63% vs 80%, P baseline (6.0 +/- 4.1% vs 15.8 +/- 4.6%, P baseline. The redistributed volume ratio of noncirrhotic and cirrhotic rats based on 99mTc sulfur-colloid SPECT were 79% and 64%, respectively. The clearance T(1/2) of FLR in cirrhotic rats based on DISIDA SPECT was decreased compared with baseline (5.2 +/- 1.9 min vs 8.6 +/- 3.1 min). The regenerated functional liver mass of cirrhotic rats after PVL is less than noncirrhotic rats, whereas the hepatocyte function of FLR in cirrhotic rats is improved relevant to tissue remodeling.

  12. Principal component analysis of dynamic fluorescence images for diagnosis of diabetic vasculopathy

    Science.gov (United States)

    Seo, Jihye; An, Yuri; Lee, Jungsul; Ku, Taeyun; Kang, Yujung; Ahn, Chulwoo; Choi, Chulhee

    2016-04-01

    Indocyanine green (ICG) fluorescence imaging has been clinically used for noninvasive visualizations of vascular structures. We have previously developed a diagnostic system based on dynamic ICG fluorescence imaging for sensitive detection of vascular disorders. However, because high-dimensional raw data were used, the analysis of the ICG dynamics proved difficult. We used principal component analysis (PCA) in this study to extract important elements without significant loss of information. We examined ICG spatiotemporal profiles and identified critical features related to vascular disorders. PCA time courses of the first three components showed a distinct pattern in diabetic patients. Among the major components, the second principal component (PC2) represented arterial-like features. The explained variance of PC2 in diabetic patients was significantly lower than in normal controls. To visualize the spatial pattern of PCs, pixels were mapped with red, green, and blue channels. The PC2 score showed an inverse pattern between normal controls and diabetic patients. We propose that PC2 can be used as a representative bioimaging marker for the screening of vascular diseases. It may also be useful in simple extractions of arterial-like features.

  13. Clinical application of photodynamic medicine technology using light-emitting fluorescence imaging based on a specialized luminous source.

    Science.gov (United States)

    Namikawa, Tsutomu; Fujisawa, Kazune; Munekage, Eri; Iwabu, Jun; Uemura, Sunao; Tsujii, Shigehiro; Maeda, Hiromichi; Kitagawa, Hiroyuki; Fukuhara, Hideo; Inoue, Keiji; Sato, Takayuki; Kobayashi, Michiya; Hanazaki, Kazuhiro

    2018-04-04

    The natural amino acid 5-aminolevulinic acid (ALA) is a protoporphyrin IX (PpIX) precursor and a new-generation photosensitive substance that accumulates specifically in cancer cells. When indocyanine green (ICG) is irradiated with near-infrared (NIR) light, it shifts to a higher energy state and emits infrared light with a longer wavelength than the irradiated NIR light. Photodynamic diagnosis (PDD) using ALA and ICG-based NIR fluorescence imaging has emerged as a new diagnostic technique. Specifically, in laparoscopic examinations for serosa-invading advanced gastric cancer, peritoneal metastases could be detected by ALA-PDD, but not by conventional visible-light imaging. The HyperEye Medical System (HEMS) can visualize ICG fluorescence as color images simultaneously projected with visible light in real time. This ICG fluorescence method is widely applicable, including for intraoperative identification of sentinel lymph nodes, visualization of blood vessels in organ resection, and blood flow evaluation during surgery. Fluorescence navigation by ALA-PDD and NIR using ICG imaging provides good visualization and detection of the target lesions that is not possible with the naked eye. We propose that this technique should be used in fundamental research on the relationship among cellular dynamics, metabolic enzymes, and tumor tissues, and to evaluate clinical efficacy and safety in multicenter cooperative clinical trials.

  14. Stereoscopic Integrated Imaging Goggles for Multimodal Intraoperative Image Guidance.

    Directory of Open Access Journals (Sweden)

    Christopher A Mela

    Full Text Available We have developed novel stereoscopic wearable multimodal intraoperative imaging and display systems entitled Integrated Imaging Goggles for guiding surgeries. The prototype systems offer real time stereoscopic fluorescence imaging and color reflectance imaging capacity, along with in vivo handheld microscopy and ultrasound imaging. With the Integrated Imaging Goggle, both wide-field fluorescence imaging and in vivo microscopy are provided. The real time ultrasound images can also be presented in the goggle display. Furthermore, real time goggle-to-goggle stereoscopic video sharing is demonstrated, which can greatly facilitate telemedicine. In this paper, the prototype systems are described, characterized and tested in surgeries in biological tissues ex vivo. We have found that the system can detect fluorescent targets with as low as 60 nM indocyanine green and can resolve structures down to 0.25 mm with large FOV stereoscopic imaging. The system has successfully guided simulated cancer surgeries in chicken. The Integrated Imaging Goggle is novel in 4 aspects: it is (a the first wearable stereoscopic wide-field intraoperative fluorescence imaging and display system, (b the first wearable system offering both large FOV and microscopic imaging simultaneously,

  15. Co-delivery of cisplatin and CJM-126 via photothermal conversion nanoparticles for enhanced synergistic antitumor efficacy

    Science.gov (United States)

    You, Chaoqun; Wu, Hongshuai; Wang, Mingxin; Gao, Zhiguo; Zhang, Xiangyang; Sun, Baiwang

    2018-01-01

    Polymeric biomaterials that can be smartly disassembled through the cleavage of the covalent bonds in a controllable way upon an environmental stimulus such as pH change, redox, special enzymes, temperature, or ultrasound, as well as light irradiation, but are otherwise stable under normal physiological conditions have attracted great attention in recent decades. The 2-(4-aminophenyl) benzothiazole molecule (CJM-126), as one of the benzothiazole derivatives, has exhibited a synergistic effect with cisplatin (CDDP) and restrains the bioactivities of a series of human breast cancer cell lines. In our study, novel NIR-responsive targeted binary-drug-loaded nanoparticles encapsulating indocyanine green (ICG) dye were prepared as a new co-delivery and combined therapeutic vehicle. The prepared drug-loaded polymeric nanoparticles (TNPs/CDDP-ICG) are stable under normal physiological conditions, while burst drugs release upon NIR laser irradiation in a mild acidic environment. The results further confirmed that the designed co-delivery platform showed higher cytotoxicity than the single free CDDP due to the synergistic treatment of CJM-126 and CDDP in vitro. Taken together, the work might provide a promising approach for effective site-specific antitumor therapy.

  16. Remotely Triggered Nano-Theranostics For Cancer Applications

    Science.gov (United States)

    Sneider, Alexandra; VanDyke, Derek; Paliwal, Shailee; Rai, Prakash

    2017-01-01

    Nanotechnology has enabled the development of smart theranostic platforms that can concurrently diagnose disease, start primary treatment, monitor response, and, if required, initiate secondary treatments. Recent in vivo experiments demonstrate the promise of using theranostics in the clinic. In this paper, we review the use of remotely triggered theranostic nanoparticles for cancer applications, focusing heavily on advances in the past five years. Remote triggering mechanisms covered include photodynamic, photothermal, phototriggered chemotherapeutic release, ultrasound, electro-thermal, magneto-thermal, X-ray, and radiofrequency therapies. Each section includes a brief overview of the triggering mechanism and summarizes the variety of nanoparticles employed in each method. Emphasis in each category is placed on nano-theranostics with in vivo success. Some of the nanotheranostic platforms highlighted include photoactivatable multi-inhibitor nanoliposomes, plasmonic nanobubbles, reduced graphene oxide-iron oxide nanoparticles, photoswitching nanoparticles, multispectral optoacoustic tomography using indocyanine green, low temperature sensitive liposomes, and receptor-targeted iron oxide nanoparticles loaded with gemcitabine. The studies reviewed here provide strong evidence that the field of nanotheranostics is rapidly evolving. Such nanoplatforms may soon enable unique advances in the clinical management of cancer. However, reproducibility in the synthesis procedures of such “smart” platforms that lend themselves to easy scale-up in their manufacturing, as well as the development of new and improved models of cancer that are more predictive of human responses, need to happen soon for this field to make a rapid clinical impact. PMID:28191450

  17. Application of fluorescence in robotic general surgery: review of the literature and state of the art.

    Science.gov (United States)

    Marano, Alessandra; Priora, Fabio; Lenti, Luca Matteo; Ravazzoni, Ferruccio; Quarati, Raoul; Spinoglio, Giuseppe

    2013-12-01

    The initial use of the indocyanine green fluorescence imaging system was for sentinel lymph node biopsy in patients with breast or colorectal cancer. Since then, application of this method has received wide acceptance in various fields of surgical oncology, and it has become a valid diagnostic tool for guiding cancer treatment. It has also been employed in numerous conventional surgical procedures with much success and benefit to the patient. The advent of minimally invasive surgery brought with it a new use for fluorescence in helping to improve the safety of these procedures, particularly for single-site procedures. In 2010, a near-infrared camera was integrated into the da Vinci Si System, creating a combination of technical and minimally invasive advantages that have been embraced by several experienced surgeons. The use of fluorescence, although useful, is considered challenging. Only a few studies are currently available on the use of fluorescence in robotic general surgery, whereas many articles have focused on its application in open and laparoscopic surgery. Many of these reports describe promising and satisfactory results, although with some shortcomings. The purpose of this article is to review the current status of the use of fluorescence in general surgery and particularly its role in robotic surgery. We also review potential uses in the future.

  18. Choriocapillary blood propagation in normal volunteers and in patients with central serous chorioretinopathy.

    Science.gov (United States)

    Komatsu, Hideki; Young-Devall, Josephine; Peyman, Gholam A; Yoneya, Shin

    2010-03-01

    To evaluate early choroidal vascular dye-filling and dye propagation patterns in normal subjects and in patients with central serous chorioretinopathy (CSC) using indocyanine green (ICG) angiography. Seventeen healthy volunteers (21-81 years old) and six patients with CSC were included. ICG angiography was performed using a modified Topcon ICG video-camera system. Subtracted images were made using the early ICG frames at a time interval of 0.12 s. Ninety frames of time-sequential images for 3 s starting from the initial dye appearance in the choroid were prepared to construct an animated video. The animated video demonstrated dye-filling and propagation patterns at the level of the choroid-choriocapillaris. In normal young volunteers, the initial phase of dye filling appeared as a uniform patchy fluorescence in the sub-foveal area, and then spread evenly in a centrifugal manner in all directions in a wave-like, pulsed fashion towards the equator. In normal older volunteers, the initial phase was similar to that in young volunteers, but centrifugal flow propagation of fluorescence towards the periphery showed an uneven progression and border. In patients with CSC, the initial dye showed a multiple patchy dye appearance with a significant time delay and loss of the centrifugal extension pattern. Using this new approach, various choroidal dye propagation patterns were observed in normal volunteers and in patients with CSC. A video of subtracted images allowed evaluation of the dynamics of dye propagation in the choroid-choriocapillaris.

  19. Age, splanchnic vasoconstriction, and heat stress during tilting

    Science.gov (United States)

    Minson, C. T.; Wladkowski, S. L.; Pawelczyk, J. A.; Kenney, W. L.

    1999-01-01

    During upright tilting, blood is translocated to the dependent veins of the legs and compensatory circulatory adjustments are necessary to maintain arterial pressure. For examination of the effect of age on these responses, seven young (23 +/- 1 yr) and seven older (70 +/- 3 yr) men were head-up tilted to 60 degrees in a thermoneutral condition and during passive heating with water-perfused suits. Measurements included heart rate (HR), cardiac output (Qc; acetylene rebreathing technique), central venous pressure (CVP), blood pressures, forearm blood flow (venous occlusion plethysmography), splanchnic and renal blood flows (indocyanine green and p-aminohippurate clearance), and esophageal and mean skin temperatures. In response to tilting in the thermoneutral condition, CVP and stroke volume decreased to a greater extent in the young men, but HR increased more, such that the fall in Qc was similar between the two groups in the upright posture. The rise in splanchnic vascular resistance (SVR) was greater in the older men, but the young men increased forearm vascular resistance (FVR) to a greater extent than the older men. The fall in Qc during combined heat stress and tilting was greater in the young compared with older men. Only four of the young men versus six of the older men were able to finish the second tilt without becoming presyncopal. In summary, the older men relied on a greater increase in SVR to compensate for a reduced ability to constrict the skin and muscle circulations (as determined by changes in FVR) during head-up tilting.

  20. Case Report of Optic Disc Drusen with Simultaneous Peripapillary Subretinal Hemorrhage and Central Retinal Vein Occlusion

    Directory of Open Access Journals (Sweden)

    David Zhiwei Law

    2014-01-01

    Full Text Available A 52-year-old Chinese gentleman presented with right eye floaters and photopsia over one week. His visual acuities were 20/20 bilaterally. Posterior segment examination showed a right eye swollen optic disc and central retinal vein occlusion (CRVO associated with an area of subretinal hemorrhage adjacent to the optic disc. Fundus fluorescein (FA and indocyanine green angiographies (ICGA of the right eye did not demonstrate choroidal neovascularization (CNV, polypoidal choroidal vasculopathy (PCV, or retinal ischemia. Ultrasound B-scan revealed optic disc drusen (ODD. In view of good vision and absence of CNV, he was managed conservatively with spontaneous resolution after two months. Commonly, ODD may directly compress and mechanically rupture subretinal vessels at the optic disc, resulting in peripapillary subretinal hemorrhage, as was likely the case in our patient. Mechanical impairment of peripapillary circulation also results in retinal ischemia and may trigger the development of choroidal neovascularization (CNV and/or polypoidal choroidal vasculopathy (PCV, leading to subretinal haemorrhage. Compromise in central venous outflow with increased retinal central venous pressure from the direct mechanical effects of enlarging ODD results in central retinal vein occlusion (CRVO. Patients with subretinal hemorrhage and CRVO from ODD should be monitored closely for the development of potentially sight-threatening complications.

  1. Self-interference fluorescence microscopy with three-phase detection for depth-resolved confocal epi-fluorescence imaging.

    Science.gov (United States)

    Braaf, Boy; de Boer, Johannes F

    2017-03-20

    Three-dimensional confocal fluorescence imaging of in vivo tissues is challenging due to sample motion and limited imaging speeds. In this paper a novel method is therefore presented for scanning confocal epi-fluorescence microscopy with instantaneous depth-sensing based on self-interference fluorescence microscopy (SIFM). A tabletop epi-fluorescence SIFM setup was constructed with an annular phase plate in the emission path to create a spectral self-interference signal that is phase-dependent on the axial position of a fluorescent sample. A Mach-Zehnder interferometer based on a 3 × 3 fiber-coupler was developed for a sensitive phase analysis of the SIFM signal with three photon-counter detectors instead of a spectrometer. The Mach-Zehnder interferometer created three intensity signals that alternately oscillated as a function of the SIFM spectral phase and therefore encoded directly for the axial sample position. Controlled axial translation of fluorescent microsphere layers showed a linear dependence of the SIFM spectral phase with sample depth over axial image ranges of 500 µm and 80 µm (3.9 × Rayleigh range) for 4 × and 10 × microscope objectives respectively. In addition, SIFM was in good agreement with optical coherence tomography depth measurements on a sample with indocyanine green dye filled capillaries placed at multiple depths. High-resolution SIFM imaging applications are demonstrated for fluorescence angiography on a dye-filled capillary blood vessel phantom and for autofluorescence imaging on an ex vivo fly eye.

  2. Internal Limiting Membrane Peeling to Prevent Post-vitrectomy Epiretinal Membrane Development in Retinal Detachment.

    Science.gov (United States)

    Akiyama, Kunihiko; Fujinami, Kaoru; Watanabe, Ken; Tsunoda, Kazushige; Noda, Toru

    2016-11-01

    To determine the efficacy of internal limiting membrane (ILM) peeling during vitrectomy for rhegmatogenous retinal detachment (RRD) regarding post-vitrectomy epiretinal membrane (ERM) development and visual outcomes. Retrospective, interventional, comparative case series. Setting: Institutional. One hundred and two consecutive eyes with RRD treated with vitrectomy and followed for at least 6 months. ILM was peeled without using dye such as indocyanine green (ICG). Observational Procedures: Patients were divided into 2 groups based on postoperative ERM development: Group 1, 81 eyes without ERM formation; Group 2, 21 eyes with ERM development. Patients also were divided into 2 subgroups: those with and without ILM peeling (58 and 44 eyes, respectively). Statistical analyses were performed between the 2 groups with/without ERM formation and between the 2 subgroups with/without ILM peeling for 5 preoperative factors including foveal involvement of the RRD, 4 intraoperative factors including ILM peeling, baseline best-corrected visual acuity (BCVA), and final BCVA. An association of ILM peeling with ERM prevention and the influence of ILM peeling on visual outcomes. ILM peeling was significantly (P peeling. ILM peeling without ICG staining during the initial vitrectomy for RRDs may prevent postoperative ERM formation with favorable visual outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Clinical outcomes of double staining and additional ILM peeling during ERM surgery.

    Science.gov (United States)

    Oh, Ha Na; Lee, Joo Eun; Kim, Hyun Woong; Yun, Il Han

    2013-08-01

    To assess the clinical outcomes in idiopathic epiretinal membrane (ERM) patients after vitrectomy and ERM removal with or without additional indocyanine green (ICG)-assisted internal limiting membrane (ILM) peeling. The medical records of 43 patients with an idiopathic ERM that underwent vitrectomy and ERM removal between July 2007 and April 2010 were reviewed. The patients were divided into two groups: triamcinolone-assisted simple ERM peeling only (group A, n = 23) and triamcinolone-assisted ERM peeling followed by ICG staining and peeling of the remaining internal ILM (group B, n = 20). No difference was found between the two groups in terms of visual acuity, macular thickness, P1 amplitude or implicit time on multifocal-electroretinogram (mfERG) at six and 12 months postoperatively. In group B, ICG staining after ERM peeling demonstrated that the ILM had been removed together with the ERM in 12 eyes (60%), and all 12 eyes showed punctate retinal hemorrhages during ERM peeling. There was no recurrence of an ERM in either group. Additional procedures involving ICG staining and ILM peeling during ERM surgery do not appear to have an additive effect on the clinical outcomes in terms of visual acuity, retinal function based on mfERG, or recurrence rate.

  4. Foveal hemorrhage in an eye with foveal hypoplasia associated with albinism.

    Science.gov (United States)

    Masuda, Naonori; Hasegawa, Taiji; Yamashita, Mariko; Ogata, Nahoko

    2014-01-01

    Oculocutaneous albinism is a group of congenital disorders caused by alterations of melanin biosynthesis. We report our findings in a patient with oculocutaneous albinism who presented with foveal hypoplasia and a foveal hemorrhage. A 48-year-old man noted a dark spot in the middle of the visual field of his right eye. He had depigmented skin, white hair, white eyebrows, and white cilia. He also had horizontal nystagmus and depigmented irides. His best-corrected visual acuity was 2/100 with -14.0 diopters in the right eye and 3/100 with -5.0 diopters in the left eye. Ophthalmoscopy showed diffuse depigmentation in both eyes and a foveal hemorrhage in the right eye. Optical coherence tomography showed the absence of a foveal pit in both eyes and a subretinal hyperreflective lesion corresponding to the foveal hemorrhage in the right eye. Fluorescein angiography showed that the retinal and choroidal vessels were relatively hypofluorescent because of the lack of a blocking effect of the pigments in the retinal pigment epithelium. Fluorescein angiography and indocyanine green angiography did not show any evidence of choroidal neovascularization in either eye. The foveal hemorrhage in the right eye spontaneously regressed and finally resolved at 3 months after onset. At the final examination, the patient reported that his vision had recovered. A foveal hemorrhage is a rare condition in an eye with foveal hypoplasia associated with albinism. The hemorrhage may be related to high myopia and also to the hypoplasia of the fovea associated with albinism.

  5. Improving drug accumulation and photothermal efficacy in tumor depending on size of ICG loaded lipid-polymer nanoparticles.

    Science.gov (United States)

    Zhao, Pengfei; Zheng, Mingbin; Yue, Caixia; Luo, Zhenyu; Gong, Ping; Gao, Guanhui; Sheng, Zonghai; Zheng, Cuifang; Cai, Lintao

    2014-07-01

    A key challenge to strengthen anti-tumor efficacy is to improve drug accumulation in tumors through size control. To explore the biodistribution and tumor accumulation of nanoparticles, we developed indocyanine green (ICG) loaded poly (lactic-co-glycolic acid) (PLGA) -lecithin-polyethylene glycol (PEG) core-shell nanoparticles (INPs) with 39 nm, 68 nm and 116 nm via single-step nanoprecipitation. These INPs exhibited good monodispersity, excellent fluorescence and size stability, and enhanced temperature response after laser irradiation. Through cell uptake and photothermal efficiency in vitro, we demonstrated that 39 nm INPs were more easily be absorbed by pancreatic carcinoma tumor cells (BxPC-3) and showed better photothermal damage than that of 68 nm and 116 nm size of INPs. Simultaneously, the fluorescence of INPs offered a real-time imaging monitor for subcellular locating and in vivo metabolic distribution. Near-infrared imaging in vivo and photothermal therapy illustrated that 68 nm INPs showed the strongest efficiency to suppress tumor growth due to abundant accumulation in BxPC-3 xenograft tumor model. The findings revealed that a nontoxic, size-dependent, theranostic INPs model was built for in vivo cancer imaging and photothermal therapy without adverse effect. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Lipidots: competitive organic alternative to quantum dots for in vivo fluorescence imaging

    Science.gov (United States)

    Gravier, Julien; Navarro, Fabrice P.; Delmas, Thomas; Mittler, Frédérique; Couffin, Anne-Claude; Vinet, Françoise; Texier, Isabelle

    2011-09-01

    The use of fluorescent nanostructures can bring several benefits on the signal to background ratio for in vitro microscopy, in vivo small animal imaging, and image-guided surgery. Fluorescent quantum dots (QDs) display outstanding optical properties, with high brightness and low photobleaching rate. However, because of their toxic element core composition and their potential long term retention in reticulo-endothelial organs such as liver, their in vivo human applications seem compromised. The development of new dye-loaded (DiO, DiI, DiD, DiR, and Indocyanine Green (ICG)) lipid nanoparticles for fluorescence imaging (lipidots) is described here. Lipidot optical properties quantitatively compete with those of commercial QDs (QTracker®705). Multichannel in vivo imaging of lymph nodes in mice is demonstrated for doses as low as 2 pmols of particles. Along with their optical properties, fluorescent lipidots display very low cytotoxicity (IC50 > 75 nM), which make them suitable tools for in vitro, and especially in vivo, fluorescence imaging applications.

  7. Fluorescence guided lymph node biopsy in large animals using direct image projection device

    Science.gov (United States)

    Ringhausen, Elizabeth; Wang, Tylon; Pitts, Jonathan; Akers, Walter J.

    2016-03-01

    The use of fluorescence imaging for aiding oncologic surgery is a fast growing field in biomedical imaging, revolutionizing open and minimally invasive surgery practices. We have designed, constructed, and tested a system for fluorescence image acquisition and direct display on the surgical field for fluorescence guided surgery. The system uses a near-infrared sensitive CMOS camera for image acquisition, a near-infra LED light source for excitation, and DLP digital projector for projection of fluorescence image data onto the operating field in real time. Instrument control was implemented in Matlab for image capture, processing of acquired data and alignment of image parameters with the projected pattern. Accuracy of alignment was evaluated statistically to demonstrate sensitivity to small objects and alignment throughout the imaging field. After verification of accurate alignment, feasibility for clinical application was demonstrated in large animal models of sentinel lymph node biopsy. Indocyanine green was injected subcutaneously in Yorkshire pigs at various locations to model sentinel lymph node biopsy in gynecologic cancers, head and neck cancer, and melanoma. Fluorescence was detected by the camera system during operations and projected onto the imaging field, accurately identifying tissues containing the fluorescent tracer at up to 15 frames per second. Fluorescence information was projected as binary green regions after thresholding and denoising raw intensity data. Promising results with this initial clinical scale prototype provided encouraging results for the feasibility of optical projection of acquired luminescence during open oncologic surgeries.

  8. Simple method of measuring pulmonary extravascular water using heavy water

    Energy Technology Data Exchange (ETDEWEB)

    Basset, G; Moreau, F; Scaringella, M; Tistchenko, S; Botter, F; Marsac, J

    1975-11-20

    The field of application of the multiple indicators dilution method in human pathology, already used to study pulmonary edema, can be extended to cover the identification and testing of all conditions leading to increase lung water. To be really practical it must be simple, fast, sensitive, inexpensive and subject to repetition; the use of non-radioactive tracers is implied. Indocyanine Green and heavy water were chosen respectively as vascular and diffusible indicators. Original methods have been developed for the treatment and isotopic analysis of blood: mass spectrometric analysis of aqueous blood extracts after deproteinisation by zinc sulphate then rapid distillation of the supernatant under helium; infrared analysis either of acetone extracts from small blood samples (100..mu..litre) or of blood itself in a continuous measurement. The infrared technique adopted has been used on rats and on men in normal and pathological situations. The results show that the method proposed for the determination of pulmonary extravascular water meets the requirements of clinicians while respecting the patients' safety, and could be generalized to other organs.

  9. Preparation of Multifunctional Fe@Au Core-Shell Nanoparticles with Surface Grafting as a Potential Treatment for Magnetic Hyperthermia

    Directory of Open Access Journals (Sweden)

    Ren-Jei Chung

    2014-01-01

    Full Text Available Iron core gold shell nanoparticles grafted with Methotrexate (MTX and indocyanine green (ICG were synthesized for the first time in this study, and preliminarily evaluated for their potential in magnetic hyperthermia treatment. The core-shell Fe@Au nanoparticles were prepared via the microemulsion process and then grafted with MTX and ICG using hydrolyzed poly(styrene-alt-maleic acid (PSMA to obtain core-shell Fe@Au-PSMA-ICG/MTX nanoparticles. MTX is an anti-cancer therapeutic, and ICG is a fluorescent dye. XRD, TEM, FTIR and UV-Vis spectrometry were performed to characterize the nanoparticles. The data indicated that the average size of the nanoparticles was 6.4 ± 09 nm and that the Au coating protected the Fe core from oxidation. MTX and ICG were successfully grafted onto the surface of the nanoparticles. Under exposure to high frequency induction waves, the superparamagnetic nanoparticles elevated the temperature of a solution in a few minutes, which suggested the potential for an application in magnetic hyperthermia treatment. The in vitro studies verified that the nanoparticles were biocompatible; nonetheless, the Fe@Au-PSMA-ICG/MTX nanoparticles killed cancer cells (Hep-G2 via the magnetic hyperthermia mechanism and the release of MTX.

  10. Preparation of Multifunctional Fe@Au Core-Shell Nanoparticles with Surface Grafting as a Potential Treatment for Magnetic Hyperthermia.

    Science.gov (United States)

    Chung, Ren-Jei; Shih, Hui-Ting

    2014-01-24

    Iron core gold shell nanoparticles grafted with Methotrexate (MTX) and indocyanine green (ICG) were synthesized for the first time in this study, and preliminarily evaluated for their potential in magnetic hyperthermia treatment. The core-shell Fe@Au nanoparticles were prepared via the microemulsion process and then grafted with MTX and ICG using hydrolyzed poly(styrene-alt-maleic acid) (PSMA) to obtain core-shell Fe@Au-PSMA-ICG/MTX nanoparticles. MTX is an anti-cancer therapeutic, and ICG is a fluorescent dye. XRD, TEM, FTIR and UV-Vis spectrometry were performed to characterize the nanoparticles. The data indicated that the average size of the nanoparticles was 6.4 ± 09 nm and that the Au coating protected the Fe core from oxidation. MTX and ICG were successfully grafted onto the surface of the nanoparticles. Under exposure to high frequency induction waves, the superparamagnetic nanoparticles elevated the temperature of a solution in a few minutes, which suggested the potential for an application in magnetic hyperthermia treatment. The in vitro studies verified that the nanoparticles were biocompatible; nonetheless, the Fe@Au-PSMA-ICG/MTX nanoparticles killed cancer cells (Hep-G2) via the magnetic hyperthermia mechanism and the release of MTX.

  11. Robotic liver surgery: technical aspects and review of the literature

    Science.gov (United States)

    Bianco, Francesco Maria; Daskalaki, Despoina; Gonzalez-Ciccarelli, Luis Fernando; Kim, Jihun; Benedetti, Enrico

    2016-01-01

    Minimally invasive surgery for liver resections has a defined role and represents an accepted alternative to open techniques for selected cases. Robotic technology can overcome some of the disadvantages of the laparoscopic technique, mainly in the most complex cases. Precise dissection and microsuturing is possible, even in narrow operative fields, allowing for a better dissection of the hepatic hilum, fine lymphadenectomy, and biliary reconstruction even with small bile ducts and easier bleeding control. This technique has the potential to allow for a greater number of major resections and difficult segmentectomies to be performed in a minimally invasive fashion. The implementation of near-infrared fluorescence with indocyanine green (ICG) also allows for a more accurate recognition of vascular and biliary anatomy. The perspectives of this kind of virtually implemented imaging are very promising and may be reflected in better outcomes. The overall data present in current literature suggests that robotic liver resections are at least comparable to both open and laparoscopic surgery in terms of perioperative and postoperative outcomes. This article provides technical details of robotic liver resections and a review of the current literature. PMID:27500143

  12. Evaluation of a radioactive and fluorescent hybrid tracer for sentinel lymph node biopsy in head and neck malignancies: prospective randomized clinical trial to compare ICG-{sup 99m}Tc-nanocolloid hybrid tracer versus {sup 99m}Tc-nanocolloid

    Energy Technology Data Exchange (ETDEWEB)

    Stoffels, Ingo; Leyh, Julia; Schadendorf, Dirk; Klode, Joachim [University Hospital Essen University of Duisburg-Essen, Department of Dermatology, Venerology and Allergology, Essen (Germany); University Duisburg-Essen, West German Cancer Center, Essen (Germany); German Cancer Consortium (DKTK), Essen (Germany); Poeppel, Thorsten [University Hospital Essen University of Duisburg-Essen, Department of Nuclear Medicine, Essen (Germany)

    2015-10-15

    There is some controversy about the value of sentinel lymph node excision (SLNE) in patients with head and neck malignancies. The gold standard for detection and targeted extirpation of the SLN is lymphoscintigraphy with {sup 99m}Tc-nanocolloid. The purpose of this prospective randomized study was to analyse the feasibility and clinical benefit of a hybrid tracer comprising the near-infrared (NIR) fluorescent indocyanine green (ICG) and {sup 99m}Tc-nanocolloid (ICG-{sup 99m}Tc-nanocolloid) in direct comparison with standard {sup 99m}Tc-nanocolloid for guiding SLNE in patients with head and neck cutaneous malignancies. We analysed the data from 40 clinically lymph node-negative patients with melanoma, high-risk cutaneous squamous cell carcinoma, Merkel cell carcinoma or sweat gland carcinoma who underwent SLNE with ICG-{sup 99m}Tc-nanocolloid (cohort A) or with the standard {sup 99m}Tc-nanocolloid (cohort B). Overall SLNs were identified preoperatively in all 20 patients (100 %) in cohort A and in 18 of 20 patients (90 %) in cohort B. The SLN basin was detected preoperatively in 18 patients (90 %) in cohort A and also in 18 patients (90 %) in cohort B. SLNs were identified intraoperatively in all 20 patients (100 %) in cohort A and in 19 patients (95 %) in cohort B (p = 0.487). Metastatic SLNs were detected in 9 patients (22.5 %), 3 (15.0 %) in cohort A and 6 (30.0 %) in cohort B (p = 0.228). The hybrid tracer ICG-{sup 99m}Tc-nanocolloid is an innovative imaging tracer, reliably and readily providing additional information for the detection and excision of SLN in the head and neck region. Therefore, SLNE with combined radioactive and NIR fluorescence guidance is an attractive option for improving the SLN detection rate in patients with cutaneous head and neck malignancies. (orig.)

  13. Changes in Hepatic Blood Flow and Liver Function during Closed Abdominal Hyperthermic Intraperitoneal Chemotherapy following Cytoreduction Surgery

    Directory of Open Access Journals (Sweden)

    Stéphanie Dupont

    2018-01-01

    Full Text Available Background. The increase in intra-abdominal pressure (IAP during closed abdominal hyperthermic intraperitoneal chemotherapy (HIPEC leads to major haemodynamic changes and potential organ dysfunction. We investigated these effects on hepatic blood flow (HBF and liver function in patients undergoing HIPEC following cytoreductive surgery and fluid management guided by dynamic preload indices. Methods. In this prospective observational clinical study including 15 consecutive patients, we evaluated HBF by transesophageal echocardiography and liver function by determination of the indocyanine green plasma disappearance rate (ICG-PDR. Friedman’s two-way analysis of variance by ranks and Wilcoxon signed-rank test were performed for statistical analysis. Results. During HIPEC, HBF was markedly reduced, resulting in the loss of any pulsatile Doppler flow signal in all but one patient. The ICG-PDR, expressed as median (interquartile 25–75, decreased from 23 (20–30 %/min to 18 (12.5–19 %/min (p<0.001. Despite a generous crystalloid infusion rate (27 (22–35 ml/kg/h, cardiac index decreased during the increased IAP period, inferior vena cava diameter decreased, stroke volume variation and pulse pressure variation increased, lung compliance dropped, and there was an augmentation in plateau pressure. All changes were significant (p<0.001 and reversed to baseline values post HIPEC. Conclusion. Despite optimizing intravenous fluids during closed abdominal HIPEC, we observed a marked decrease in HBF and liver function. Both effects were transient and limited to the period of HIPEC but could influence the choice between closed or open abdominal cavity procedure for HIPEC and should be considered in similar clinical situations of increased IAP.

  14. Light/laser therapy in the treatment of acne vulgaris.

    Science.gov (United States)

    Nouri, Keyvan; Villafradez-Diaz, L Magaly

    2005-12-01

    Acne vulgaris is one of the most prevalent skin diseases known. As common as this condition is, the social and psychological consequences are limitless. Although current treatments are available and include topical or oral antibiotics, it is crucial to develop a less risky and more effective therapy such as light/laser therapy. This article focuses specifically on the benefits of the light/laser treatment on acne vulgaris. Porphyrins accumulated in the bacteria, Propionibacterium acnes, one of the etiologic factors involved in the pathogenesis, allows phototherapy to be a successful modality. They have specific absorption peaks at which lasers have optimal effects. The longer the wavelength of the light is, the deeper its penetration and thus the greater its damage to the sebaceous glands. Although blue light is best for the activation of porphyrins, red light is best for deeper penetration and an anti-inflammatory effect. Ultraviolet (UV) light, although it may have initial an anti-inflammatory effects, has been proven to be potentially carcinogenic and have adverse effects such as aging (by UV-A) and burning (by UV-B). Previous studies indicate successful long-term intervention and selective damage of the sebaceous glands by using a diode laser with indocyanine green (ICG) dye. Mid-infrared lasers have been found to decrease lesion counts while also reducing the oiliness of skin and the scarring process. Nonablative laser treatment of acne scars using the Er:YAG laser with a short-pulsed mode has been successful in reducing the appearance of scars by stimulating neocollagenesis. The light/laser therapy has started to be explored with promising results in highly selected patients that require further investigation in greater populations and well-designed protocols.

  15. Microjet-assisted dye-enhanced diode laser ablation of cartilaginous tissue

    Science.gov (United States)

    Pohl, John; Bell, Brent A.; Motamedi, Massoud; Frederickson, Chris J.; Wallace, David B.; Hayes, Donald J.; Cowan, Daniel

    1994-08-01

    Recent studies have established clinical application of laser ablation of cartilaginous tissue. The goal of this study was to investigate removal of cartilaginous tissue using diode laser. To enhance the interaction of laser light with tissue, improve the ablation efficiency and localize the extent of laser-induced thermal damage in surrounding tissue, we studied the use of a novel delivery system developed by MicroFab Technologies to dispense a known amount of Indocyanine Green (ICG) with a high spatial resolution to alter the optical properties of the tissue in a controlled fashion. Canine intervertebral disks were harvested and used within eight hours after collection. One hundred forty nL of ICG was topically applied to both annulus and nucleus at the desired location with the MicroJet prior to each irradiation. Fiber catheters (600 micrometers ) were used and positioned to irradiate the tissue with a 0.8 mm spot size. Laser powers of 3 - 10 W (Diomed, 810 nm) were used to irradiate the tissue with ten pulses (200 - 500 msec). Discs not stained with ICG were irradiated as control samples. Efficient tissue ablation (80 - 300 micrometers /pulse) was observed using ICG to enhance light absorption and confine thermal damage while there was no observable ablation in control studied. The extent of tissue damage observed microscopically was limited to 50 - 100 micrometers . The diode laser/Microjet combination showed promise for applications involving removal of cartilaginous tissue. This procedure can be performed using a low power compact diode laser, is efficient, and potentially more economical compared to procedures using conventional lasers.

  16. Factors Associated with Lower Extremity Dysmorphia Caused by Lower Extremity Lymphoedema.

    Science.gov (United States)

    Yamamoto, T; Yamamoto, N; Yoshimatsu, H; Narushima, M; Koshima, I

    2017-07-01

    Indocyanine green (ICG) lymphography has been reported to be useful for the early diagnosis of lymphoedema. However, no study has reported the usefulness of ICG lymphography for evaluation of lymphoedema with lower extremity dysmorphia (LED). This study aimed to elucidate independent factors associated with LED in secondary lower extremity lymphoedema (LEL) patients. This was a retrospective observational study of 268 legs of 134 secondary LEL patients. The medical charts were reviewed to obtain data of clinical demographics and ICG lymphography based severity stage (leg dermal backflow [LDB] stage). LED was defined as a leg with a LEL index of 250 or higher. Logistic regression analysis was used to identify independent factors associated with LED. LED was observed in 106 legs (39.6%). Multivariate analysis revealed that independent factors associated with LED were higher LDB stages compared with LDB stage 0 (LDB stage III; OR 17.586; 95% CI 2.055-150.482; p = .009) (LDB stage IV; OR 76.794; 95% CI 8.132-725.199; p < .001) (LDB stage V; OR 47.423; 95% CI 3.704-607.192; p = .003). On the other hand, inverse associations were observed in higher age (65 years or older; OR 0.409; 95% CI 0.190-0.881; p = .022) and higher body mass index (25 kg/m 2 or higher; OR 0.408; 95% CI 0.176-0.946; p = .037). Independent factors associated with LED were elucidated. ICG lymphography based severity stage showed the strongest association with LED, and was useful for evaluation of progressed LEL with LED. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  17. First-in-human evaluation of a hybrid modality that allows combined radio- and (near-infrared) fluorescence tracing during surgery

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Nynke S. van den [Leiden University Medical Center, Interventional Molecular Imaging Laboratory, Department of Radiology (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Simon, Herve [Eurorad S.A., Eckbolsheim (France); Kleinjan, Gijs H. [Leiden University Medical Center, Interventional Molecular Imaging Laboratory, Department of Radiology (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Engelen, Thijs [Leiden University Medical Center, Interventional Molecular Imaging Laboratory, Department of Radiology (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands); Bunschoten, Anton; Welling, Mick M. [Leiden University Medical Center, Interventional Molecular Imaging Laboratory, Department of Radiology (Netherlands); Tijink, Bernard M. [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands); Horenblas, Simon [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); Chambron, Jacques [The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Leeuwen, Fijs W.B. van [Leiden University Medical Center, Interventional Molecular Imaging Laboratory, Department of Radiology (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Urology, Amsterdam (Netherlands); The Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands)

    2015-10-15

    The clinical introduction of the hybrid tracer indocyanine green (ICG)-{sup 99m}Tc-nanocolloid, composed of a radioactive and a near-infrared (NIR) fluorescence component, has created the need for surgical (imaging) modalities that allow for simultaneous detection of both signals. This study describes the first-in-human use of a prototype opto-nuclear probe during sentinel node (SN) biopsy using ICG-{sup 99m}Tc-nanocolloid. To allow for fluorescence tracing, a derivative of the conventional gamma probe technology was generated in which two optical fibers were integrated to allow for excitation (785 nm) and emission signal collection (> 810 nm). The ability of this opto-nuclear probe to detect the fluorescence signal of the hybrid tracer ICG-{sup 99m}Tc-nanocolloid was firstly determined ex vivo in (non)SNs samples obtained from 41 patients who underwent hybrid tracer-based SN biopsy in the head and neck or urogenital area. In an in vivo proof-of-concept study in nine of these 41 patients, SNs were localized using combined gamma and fluorescence tracing with the opto-nuclear probe. Fluorescence tracing was performed in a similar manner as gamma tracing and under ambient light conditions. Ex vivo, the gamma tracing option of the opto-nuclear probe correctly identified the SN in all 150 evaluated (non)SN samples. Ex vivo fluorescence tracing in the low-sensitivity mode correctly identified 71.7 % of the samples. This increased to 98.9 % when fluorescence tracing was performed in the high-sensitivity mode. In vivo fluorescence tracing (high-sensitivity mode) accurately identified the SNs in all nine patients (20 SNs evaluated; 100 %). This study demonstrates the first-in-human evaluation of a hybrid modality capable of detecting both gamma and fluorescence signals during a surgical procedure. Fluorescence tracing could be performed in ambient light. (orig.)

  18. Microscopic characterization of collagen modifications induced by low-temperature diode-laser welding of corneal tissue.

    Science.gov (United States)

    Matteini, Paolo; Rossi, Francesca; Menabuoni, Luca; Pini, Roberto

    2007-08-01

    Laser welding of corneal tissue that employs diode lasers (810 nm) at low power densities (12-20 W/cm(2)) in association with Indocyanine Green staining of the wound is a technique proposed as an alternative to conventional suturing procedures. The aim of this study is to evaluate, by means of light (LM) and transmission electron microscopy (TEM) analyses, the structural modifications induced in laser-welded corneal stroma. Experiments were carried out in 20 freshly enucleated pig eyes. A 3.5 mm in length full-thickness cut was produced in the cornea, and was then closed by laser welding. Birefringence modifications in samples stained with picrosirius red dye were analyzed by polarized LM to assess heat damage. TEM analysis was performed on ultra-thin slices, contrasted with uranyl acetate and lead citrate, in order to assess organization and size of type I collagen fibrils after laser welding. LM evidenced bridges of collagen bundles between the wound edges, with a loss of regular lamellar organization at the welded site. Polarized LM indicated that birefringence properties were mostly preserved after laser treatment. TEM examinations revealed the presence of quasi-ordered groups of fibrils across the wound edges preserving their interfibrillar spacing. These fibrils appeared morphologically comparable to those in the control tissue, indicating that type I collagen was not denatured during the diode laser corneal welding. The preservation of substantially intact, undenatured collagen fibrils in laser-welded corneal wounds supported the thermodynamic studies that we carried out recently, which indicated temperatures below 66 degrees C at the weld site under laser irradiation. This observation enabled us to hypothesize that the mechanism, proposed in the literature, of unwinding of collagen triple helixes followed by fibrils "interdigitation" is not likely to occur in the welding process that we set up for the corneal suturing.

  19. Laser solder welding of articular cartilage: tensile strength and chondrocyte viability.

    Science.gov (United States)

    Züger, B J; Ott, B; Mainil-Varlet, P; Schaffner, T; Clémence, J F; Weber, H P; Frenz, M

    2001-01-01

    The surgical treatment of full-thickness cartilage defects in the knee joint remains a therapeutic challenge. Recently, new techniques for articular cartilage transplantation, such as mosaicplasty, have become available for cartilage repair. The long-term success of these techniques, however, depends not only on the chondrocyte viability but also on a lateral integration of the implant. The goal of this study was to evaluate the feasibility of cartilage welding by using albumin solder that was dye-enhanced to allow coagulation with 808-nm laser diode irradiation. Conventional histology of light microscopy was compared with a viability staining to precisely determine the extent of thermal damage after laser welding. Indocyanine green (ICG) enhanced albumin solder (25% albumin, 0.5% HA, 0.1% ICG) was used for articular cartilage welding. For coagulation, the solder was irradiated through the cartilage implant by 808-nm laser light and the tensile strength of the weld was measured. Viability staining revealed a thermal damage of typically 500 m in depth at an irradiance of approximately 10 W/cm(2) for 8 seconds, whereas conventional histologies showed only half of the extent found by the viability test. Heat-bath investigations revealed a threshold temperature of minimum 54 degrees C for thermal damage of chondrocytes. Efficient cartilage bonding was obtained by using bovine albumin solder as adhesive. Maximum tensile strength of more than 10 N/cm(2) was achieved. Viability tests revealed that the thermal damage is much greater (up to twice) than expected after light microscopic characterization. This study shows the feasibility to strongly laser weld cartilage on cartilage by use of a dye-enhanced albumin solder. Possibilities to reduce the range of damage are suggested. Copyright 2001 Wiley-Liss, Inc.

  20. Dye-enhanced protein solders and patches in laser-assisted tissue welding.

    Science.gov (United States)

    Small, W; Heredia, N J; Maitland, D J; Da Silva, L B; Matthews, D L

    1997-01-01

    This study examines the use of dye-enhanced protein bonding agents in 805 nm diode laser-assisted tissue welding. A comparison of an albumin liquid solder and collagen solid-matrix patches used to repair arteriotomies in an in vitro porcine model is presented. Extrinsic bonding media in the form of solders and patches have been used to enhance the practice of laser tissue welding. Preferential absorption of the laser wavelength has been achieved by the incorporation of chromophores. Both the solder and the patch included indocyanine green dye (ICG) to absorb the 805 nm continuous-wave diode laser light used to perform the welds. Solder-mediated welds were divided into two groups (high power/short exposure and low power/long exposure), and the patches were divided into three thickness groups ranging from 0.1 to 1.3 mm. The power used to activate the patches was constant, but the exposure time was increased with patch thickness. Burst pressure results indicated that solder-mediated and patched welds yielded similar average burst strengths in most cases, but the patches provided a higher success rate (i.e., more often exceeded 150 mmHg) and were more consistent (i.e., smaller standard deviation) than the solder. The strongest welds were obtained using 1.0-1.3 mm thick patches, while the high power/short exposure solder group was the weakest. Though the solder and patches yielded similar acute weld strengths, the solid-matrix patches facilitated the welding process and provided consistently strong welds. The material properties of the extrinsic agents influenced their performance.

  1. Laser-tissue soldering with biodegradable polymer films in vitro: film surface morphology and hydration effects.

    Science.gov (United States)

    Sorg, B S; Welch, A J

    2001-01-01

    Previous research introduced the concept of using biodegradable polymer film reinforcement of a liquid albumin solder for improvement of the tensile strength of repaired incisions in vitro. In this study, the effect of creating small pores in the PLGA films on the weld breaking strength is studied. Additionally, the effect of hydration on the strength of the reinforced welds is investigated. A 50%(w/v) bovine serum albumin solder with 0.5 mg/mL Indocyanine Green dye was used to repair an incision in bovine aorta. The solder was coagulated with an 806-nm CW diode laser. A poly(DL-lactic-co-glycolic acid) (PLGA) film was used to reinforce the solder (the controls had solder but no reinforcement). Breaking strengths were measured acutely and after hydration in saline for 1 and 2 days. The data were analyzed by ANOVA (P < 0.05) and multiple comparisons of means were performed using the Newman-Keuls test. The creation of pores in the PLGA films qualitatively improved the film flexibility without having an apparent adverse effect on the breaking strength, while the actual technique of applying the film and solder had more of an effect. The acute maximum average breaking strengths of some of the film reinforced specimens (114.7 g-134.4 g) were significantly higher (P < 0.05) than the acute maximum average breaking strength of the unreinforced control specimens (68.3 g). Film reinforced specimens were shown to have a statistically significantly higher breaking strength than unreinforced controls after 1- and 2-day hydration. Reinforcement of liquid albumin solders in laser-assisted incision repair appears to have advantages over conventional methods that do not reinforce the cohesive strength of the solder in terms of acute breaking strength and after immersion in moist environments for short periods of time. Using a film with the solder applied to one surface only may be advantageous over other techniques.

  2. Optimal parameters for laser tissue soldering

    Science.gov (United States)

    McNally-Heintzelman, Karen M.; Sorg, Brian S.; Chan, Eric K.; Welch, Ashley J.; Dawes, Judith M.; Owen, Earl R.

    1998-07-01

    Variations in laser irradiance, exposure time, solder composition, chromophore type and concentration have led to inconsistencies in published results of laser-solder repair of tissue. To determine optimal parameters for laser tissue soldering, an in vitro study was performed using an 808-nm diode laser in conjunction with an indocyanine green (ICG)- doped albumin protein solder to weld bovine aorta specimens. Liquid and solid protein solders prepared from 25% and 60% bovine serum albumin (BSA), respectively, were compared. The effects of laser irradiance and exposure time on tensile strength of the weld and temperature rise as well as the effect of hydration on bond stability were investigated. Optimum irradiance and exposure times were identified for each solder type. Increasing the BSA concentration from 25% to 60% greatly increased the tensile strength of the weld. A reduction in dye concentration from 2.5 mg/ml to 0.25 mg/ml was also found to result in an increase in tensile strength. The strongest welds were produced with an irradiance of 6.4 W/cm2 for 50 s using a solid protein solder composed of 60% BSA and 0.25 mg/ml ICG. Steady-state solder surface temperatures were observed to reach 85 plus or minus 5 degrees Celsius with a temperature gradient across the solid protein solder strips of between 15 and 20 degrees Celsius. Finally, tensile strength was observed to decrease significantly (20 to 25%) after the first hour of hydration in phosphate-buffered saline. No appreciable change was observed in the strength of the tissue bonds with further hydration.

  3. Gingiva laser welding: preliminary study on an ex vivo porcine model.

    Science.gov (United States)

    Rasca, Emilia; Nyssen-Behets, Catherine; Tielemans, Marc; Peremans, André; Hendaoui, Nordine; Heysselaer, Daniel; Romeo, Umberto; Nammour, Samir

    2014-08-01

    The use of lasers to fuse different tissues has been studied for 50 years. As none of these experiments concerned the oral soft tissues, our objective was to assess the feasibility of laser gingiva welding. Porcine full-thickness gingival flaps served to prepare calibrated samples in the middle of which a 2 cm long incision was closed, either by conventional suture or by laser tissue welding (LTW). To determine the irradiation conditions yielding the best tensile strength, 13 output power values, from 0.5 to 5 W, delivered either at 10 Hz or in continuous wave mode, were tested on six indocyanine green (ICG) concentrations, from 8% to 13% (588 samples). Then, some samples served to compare the tensile strength between the laser welded and the sutured gingiva; the other samples were histologically processed in order to evaluate the thermal damage extent. The temperature rise during the LTW was measured by thermocouples. Another group of 12 samples was used to measure the temperature elevation by thermal camera. In the laser welding groups, the best tensile strength (pwelded gingiva at 4.5 W, 10 Hz, and 9% ICG solution. The mean temperature was 74±5.4°C at the upper surface and 42±8.9°C at the lower surface. The damaged zone averaged 333 μm at the upper surface. The 808 nm diode laser associated with ICG can achieve oral mucosa LTW, which is conceivable as a promising technique of gingival repair.

  4. Laser-activated protein bands for peripheral nerve repair

    Science.gov (United States)

    Lauto, Antonio; Trickett, Rodney I.; Malik, Richard; Dawes, Judith M.; Owen, Earl R.

    1996-01-01

    A 100 micrometer core optical fiber-coupled 75 mW diode laser operating at a wavelength of 800 nm has been used in conjunction with a protein solder to stripe weld severed rat tibial nerves, reducing the long operating time required for microsurgical nerve repair. Welding is produced by selective laser denaturation of the protein based solder which contains the dye indocyanine green. Operating time for laser soldering was 10 plus or minus 5 min. (n equals 24) compared to 23 plus or minus 9 min (n equals 13) for microsuturing. The laser solder technique resulted in patent welds with a tensile strength of 15 plus or minus 5 g, while microsutured nerves had a tensile strength of 40 plus or minus 10 g. Histopathology of the laser soldered nerves, conducted immediately after surgery, displayed solder adhesion to the outer membrane with minimal damage to the inner axons of the nerves. An in vivo study, with a total of fifty-seven adult male wistar rats, compared laser solder repaired tibial nerves to conventional microsuture repair. Twenty-four laser soldered nerves and thirteen sutured nerves were characterized at three months and showed successful regeneration with average compound muscle action potentials (CMAP) of 2.4 plus or minus 0.7 mV and 2.7 plus or minus 0.8 mV respectively. Histopathology of the in vivo study, confirmed the comparable regeneration of axons in laser and suture operated nerves. A faster, less damaging and long lasting laser based anastomotic technique is presented.

  5. Near-Infrared Fluorescence Detection of Acetylcholine in Aqueous Solution Using a Complex of Rhodamine 800 and p-Sulfonato-calix[8]arene

    Science.gov (United States)

    Jin, Takashi

    2010-01-01

    The complexing properties of p-sulfonatocalix[n]arenes (n = 4: S[4], n = 6: S[6], and n = 8: S[8]) for rhodamine 800 (Rh800) and indocyanine green (ICG) were examined to develop a near-infrared (NIR) fluorescence detection method for acetylcholine (ACh). We found that Rh800 (as a cation) forms an inclusion complex with S[n], while ICG (as a twitter ion) have no binding ability for S[n]. The binding ability of Rh800 to S[n] decreased in the order of S[8] > S[6] >> S[4]. By the formation of the complex between Rh800 and S[8], fluorescence intensity of the Rh800 was significantly decreased. From the fluorescence titration of Rh800 by S[8], stoichiometry of the Rh800-S[8] complex was determined to be 1:1 with a dissociation constant of 2.2 μM in PBS. The addition of ACh to the aqueous solution of the Rh800-S[8] complex caused a fluorescence increase of Rh800, resulting from a competitive replacement of Rh800 by ACh in the complex. From the fluorescence change by the competitive fluorophore replacement, stoichiometry of the Rh800-ACh complex was found to be 1:1 with a dissociation constant of 1.7 mM. The effects of other neurotransmitters on the fluorescence spectra of the Rh800-S[8] complex were examined for dopamine, GABA, glycine, and l-asparatic acid. Among the neurotransmitters examined, fluorescence response of the Rh800-S[8] complex was highly specific to ACh. Rh800-S[8] complexes can be used as a NIR fluorescent probe for the detection of ACh (5 × 10−4−10−3 M) in PBS buffer (pH = 7.2). PMID:22294934

  6. Confocal laser endomicroscopy for diagnosis and histomorphologic imaging of brain tumors in vivo.

    Directory of Open Access Journals (Sweden)

    Sebastian Foersch

    Full Text Available Early detection and evaluation of brain tumors during surgery is crucial for accurate resection. Currently cryosections during surgery are regularly performed. Confocal laser endomicroscopy (CLE is a novel technique permitting in vivo histologic imaging with miniaturized endoscopic probes at excellent resolution. Aim of the current study was to evaluate CLE for in vivo diagnosis in different types and models of intracranial neoplasia. In vivo histomorphology of healthy brains and two different C6 glioma cell line allografts was evaluated in rats. One cell line expressed EYFP, the other cell line was used for staining with fluorescent dyes (fluorescein, acriflavine, FITC-dextran and Indocyanine green. To evaluate future application in patients, fresh surgical resection specimen of human intracranial tumors (n = 15 were examined (glioblastoma multiforme, meningioma, craniopharyngioma, acoustic neurinoma, brain metastasis, medulloblastoma, epidermoid tumor. Healthy brain tissue adjacent to the samples served as control. CLE yielded high-quality histomorphology of normal brain tissue and tumors. Different fluorescent agents revealed distinct aspects of tissue and cell structure (nuclear pattern, axonal pathways, hemorrhages. CLE discrimination of neoplastic from healthy brain tissue was easy to perform based on tissue and cellular architecture and resemblance with histopathology was excellent. Confocal laser endomicroscopy allows immediate in vivo imaging of normal and neoplastic brain tissue at high resolution. The technology might be transferred to scientific and clinical application in neurosurgery and neuropathology. It may become helpful to screen for tumor free margins and to improve the surgical resection of malignant brain tumors, and opens the door to in vivo molecular imaging of tumors and other neurologic disorders.

  7. Introducing navigation during melanoma-related sentinel lymph node procedures in the head-and-neck region.

    Science.gov (United States)

    KleinJan, Gijs H; Karakullukçu, Baris; Klop, W Martin C; Engelen, Thijs; van den Berg, Nynke S; van Leeuwen, Fijs W B

    2017-08-17

    Intraoperative sentinel node (SN) identification in patients with head-and-neck malignancies can be challenging due to unexpected drainage patterns and anatomical complexity. Here, intraoperative navigation-based guidance technologies may provide outcome. In this study, gamma camera-based freehandSPECT was evaluated in combination with the hybrid tracer ICG- 99m Tc-nanocolloid. Eight patients with melanoma located in the head-and-neck area were included. Indocyanine green (ICG)- 99m Tc-nanocolloid was injected preoperatively, whereafter lymphoscintigraphy and SPECT/CT imaging were performed in order to define the location of the SN(s). FreehandSPECT scans were generated in the operation room using a portable gamma camera. For lesion localization during surgery, freehandSPECT scans were projected in an augmented reality video-view that was used to spatially position a gamma-ray detection probe. Intraoperative fluorescence imaging was used to confirm the accuracy of the navigation-based approach and identify the exact location of the SNs. Preoperatively, 15 SNs were identified, of which 14 were identified using freehandSPECT. Navigation towards these nodes using the freehandSPECT approach was successful in 13 nodes. Fluorescence imaging provided optical confirmation of the navigation accuracy in all patients. In addition, fluorescence imaging allowed for the identification of (clustered) SNs that could not be identified based on navigation alone. The use of gamma camera-based freehandSPECT aids intraoperative lesion identification and, with that, supports the transition from pre- to intraoperative imaging via augmented reality display and directional guidance.

  8. Combined Partial Penectomy With Bilateral Robotic Inguinal Lymphadenectomy Using Near-infrared Fluorescence Guidance.

    Science.gov (United States)

    Sávio, Luís Felipe; Panizzutti Barboza, Marcelo; Alameddine, Mahmoud; Ahdoot, Michael; Alonzo, David; Ritch, Chad R

    2018-03-01

    To describe our novel technique for performing a combined partial penectomy and bilateral robotic inguinal lymphadenectomy using intraoperative near-infrared (NIR) fluorescence guidance with indocyanine green (ICG) and the DaVinci Firefly camera system. A 58-year-old man presented status post recent excisional biopsy of a 2-cm lesion on the left coronal aspect of the glans penis. Pathology revealed "invasive squamous cell carcinoma of the penis with multifocal positive margins." His examination was suspicious for cT2 primary and his inguinal nodes were cN0. He was counseled to undergo partial penectomy with possible combined vs staged bilateral robotic inguinal lymphadenectomy. Preoperative computed tomography scan was negative for pathologic lymphadenopathy. Before incision, 5 mL of ICG was injected subcutaneously beneath the tumor. Bilateral thigh pockets were then developed simultaneously and a right, then left robotic modified inguinal lymphadenectomy was performed using NIR fluorescence guidance via the DaVinci Firefly camera. A partial penectomy was then performed in the standard fashion. The combined procedure was performed successfully without complication. Total operative time was 379 minutes and total robotic console time was 95 minutes for the right and 58 minutes to the left. Estimated blood loss on the right and left were 15 and 25 mL, respectively. A total of 24 lymph nodes were retrieved. This video demonstrates a safe and feasible approach for combined partial penectomy and bilateral inguinal lymphadenectomy with NIR guidance using ICG and the DaVinci Firefly camera system. The combined robotic approach has minimal morbidity and avoids the need for a staged procedure. Furthermore, use of NIR guidance with ICG during robotic inguinal lymphadenectomy is feasible and may help identify sentinel lymph nodes and improve the quality of dissection. Further studies are needed to confirm the utility of NIR guidance for robotic sentinel lymph node

  9. Short-term efficacy of intravitreal conbercept in treatment-naive patients with polypoidal choroidal vasculopathy

    Directory of Open Access Journals (Sweden)

    Peng Y

    2018-02-01

    Full Text Available Yuting Peng, Xiongze Zhang, Miaoling Li, Bing Liu, Lan Mi, Chengguo Zuo, Feng Wen State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China Introduction: To evaluate the functional and morphological outcomes of intravitreal conbercept monotherapy in patients with polypoidal choroidal vasculopathy (PCV. Materials and methods: In this retrospective, observational case series study, we reviewed medical records of 48 eyes (48 patients with naive PCV that were treated with a series of 3 monthly intravitreal injections of 0.5 mg of conbercept followed by as-needed injections (3+pro re nata. All patients completed at least 6 months of monthly follow-up. Changes in the best-corrected visual acuity, optical coherence tomography, and indocyanine green angiography were retrospectively evaluated. Results: At 6 months, the mean best-corrected visual acuity significantly improved from 0.89±0.35 (20/160 in Snellen equivalent at baseline to 0.58±0.26 (Snellen equivalent of 20/80; P<0.001, and 60.42% (29/48 of eyes had an improvement of three lines of vision; the mean central retinal thickness significantly decreased from 333.56±171.04 µm at baseline to 187.65±54.46 µm (P<0.001, and 93.75% (45/48 achieved a dry macula. At 3 months, 6 of 32 eyes (18.75% showed partial regression of branching vascular network, 14 of 32 (43.75% patients showed complete resolution of polyps. The mean number of injections was 3.4±0.9 through 6 months. No conbercept-related systemic or ocular adverse effects were observed. Conclusion: Intravitreal injection of conbercept using “3+pro re nata” regimen significantly improved visual acuity and anatomical outcomes in treatment-naive patients with PCV. Keywords: conbercept, intravitreal injection, PCV, short-term efficacy, “3+PRN”

  10. Novel Index (Hepatic Receptor: IHR) to Evaluate Hepatic Functional Reserve Using (99m)Tc-GSA Scintigraphy.

    Science.gov (United States)

    Hasegawa, Daisuke; Onishi, Hideo; Matsutomo, Norikazu

    2016-02-01

    This study aimed to evaluate the novel index of hepatic receptor (IHR) on the regression analysis derived from time activity curve of the liver for hepatic functional reserve. Sixty patients had undergone (99m)Tc-galactosyl serum albumin ((99m)Tc-GSA) scintigraphy in the retrospective clinical study. Time activity curves for liver were obtained by region of interest (ROI) on the whole liver. A novel hepatic functional predictor was calculated with multiple regression analysis of time activity curves. In the multiple regression function, the objective variables were the indocyanine green (ICG) retention rate at 15 min, and the explanatory variables were the liver counts in 3-min intervals until end from beginning. Then, this result was defined by IHR, and we analyzed the correlation between IHR and ICG, uptake ratio of the heart at 15 minutes to that at 3 minutes (HH15), uptake ratio of the liver to the liver plus heart at 15 minutes (LHL15), and index of convexity (IOC). Regression function of IHR was derived as follows: IHR=0.025×L(6)-0.052×L(12)+0.027×L(27). The multiple regression analysis indicated that liver counts at 6 min, 12 min, and 27 min were significantly related to objective variables. The correlation coefficient between IHR and ICG was 0.774, and the correlation coefficient between ICG and conventional indices (HH15, LHL15, and IOC) were 0.837, 0.773, and 0.793, respectively. IHR had good correlation with HH15, LHL15, and IOC. The finding results suggested that IHR would provide clinical benefit for hepatic functional assessment in the (99m)Tc-GSA scintigraphy.

  11. Role of ICG-{sup 99m}Tc-nanocolloid for sentinel lymph node detection in cervical cancer: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Paredes, Pilar; Vidal-Sicart, Sergi; Lomena, Francisco [Hospital Clinic, Nuclear Medicine Department, Barcelona (Spain); Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Campos, Francisco [Hospital Clinic, Nuclear Medicine Department, Radiopharmacy Unit, Barcelona (Spain); Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Tapias, Andres; Sanchez, Nuria [Hospital Clinic, Nuclear Medicine Department, Barcelona (Spain); Martinez, Sergio; Pahisa, Jaume; Torne, Aureli; Carmona, Francesc [Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Institut Clinic of Gynecology, Obstetrics and Neonatology, Hospital Clinic, Barcelona (Spain); Carballo, Lorena [Hospital Clinic, Nuclear Medicine Department, Radiopharmacy Unit, Barcelona (Spain); Ordi, Jaume [Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Barcelona (Spain); Hospital Clinic, Department of Pathology, Barcelona (Spain); Centre de Recerca en Salut Internacional de Barcelona (CRESIB), Barcelona (Spain)

    2017-10-15

    Sentinel lymph node biopsy (SLNB) can be used for nodal staging in early cervical cancer. For this purpose, the tracers most commonly used are radiotracers based on technetium. For the last decade, indocyanine green (ICG) has been used as a tracer for SLNB in other malignancies with excellent results and, more recently, a combination of ICG and a radiotracer has been shown to have the advantages of both tracers. The aim of this study was to evaluate the role of ICG-{sup 99m}Tc-nanocolloid in SLN detection in patients with cervical cancer. This prospective study included 16 patients with cervical cancer. The hybrid tracer was injected the day (19-21 h) before surgery for planar and SPECT/CT lymphoscintigraphy. Blue dye was administered periorificially in 14 patients. SLNs were removed according to their distribution on lymphoscintigraphy and when radioactive, fluorescent and/or stained with blue dye. Nodal specimens were pathologically analysed for metastases including by immunochemistry. Lymphoscintigraphy and SPECT/CT showed drainage in all patients. A total of 69 SLNs were removed, of which 66 were detected by their radioactivity signal and 67 by their fluorescence signal. Blue dye identified only 35 SLNs in 12 of the 14 patients (85.7%). All patients showed bilateral pelvic drainage. Micrometastases were diagnosed in two patients, and were the only lymphatic nodes involved. SLNB with ICG-{sup 99m}Tc-nanocolloid is feasible and safe in patients with early cervical cancer. This hybrid tracer provided bilateral SLN detection in all patients and a higher detection rate than blue dye, so it could become an alternative to the combined technique. (orig.)

  12. MuSIC report III: tumour microcirculation patterns and development of metastasis in long-term follow-up of melanocytic uveal tumours.

    Science.gov (United States)

    Klingenstein, Annemarie; Schaumberger, Markus M; Freeman, William R; Folberg, Robert; Mueller, Arthur J; Schaller, Ulrich C

    2016-03-01

    To statistically determine differences in microcirculation patterns between nevi and uveal melanomas and the influence of these patterns on metastatic potential in the long-term follow-up of 112 patients with melanocytic uveal tumours. In vivo markers indicating malignancy and metastatic potential have implications for treatment decision. Primary diagnosis and work-up included clinical examination, fundus photography, standardized A and B scan echography as well as evaluation of tumour microcirculation patterns via confocal fluorescein and indocyanine green angiography (ICGA). Patient data were collected from the patient files, the tumour registry or personal contact. Statistical analysis was performed with spss 22.0 using chi-square, Fisher's exact test and Kaplan-Meier survival analysis. Forty-three uveal melanocytic lesions remained untreated and were retrospectively classified as benign nevi, whereas 69 lesions were malignant melanomas (T1: 32, T2: 28, T3: 6 and T4: 3). 'Silent' and 'arcs without branching' were found significantly more often in nevi (p = 0.001 and p = 0.010), whereas 'parallel with cross-linking' and 'networks' were significantly more frequent in melanomas (p = 0.022 and p = 0.029). The microcirculation pattern 'parallel with cross-linking' proved significantly more frequent in patients who developed metastases (p = 0.001). Certain microcirculation patterns may guide us in differentiating uveal nevi from malignant melanomas. A non-invasive prognostic marker can be of great value for borderline lesions in which cytology is less likely taken. 'Parallel with cross-linking' did not only indicate malignancy, but it was also associated with later tumour metastasis. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Near-infrared fluorescence imaging with a mobile phone (Conference Presentation)

    Science.gov (United States)

    Ghassemi, Pejhman; Wang, Bohan; Wang, Jianting; Wang, Quanzeng; Chen, Yu; Pfefer, T. Joshua

    2017-03-01

    Mobile phone cameras employ sensors with near-infrared (NIR) sensitivity, yet this capability has not been exploited for biomedical purposes. Removing the IR-blocking filter from a phone-based camera opens the door to a wide range of techniques and applications for inexpensive, point-of-care biophotonic imaging and sensing. This study provides proof of principle for one of these modalities - phone-based NIR fluorescence imaging. An imaging system was assembled using a 780 nm light source along with excitation and emission filters with 800 nm and 825 nm cut-off wavelengths, respectively. Indocyanine green (ICG) was used as an NIR fluorescence contrast agent in an ex vivo rodent model, a resolution test target and a 3D-printed, tissue-simulating vascular phantom. Raw and processed images for red, green and blue pixel channels were analyzed for quantitative evaluation of fundamental performance characteristics including spectral sensitivity, detection linearity and spatial resolution. Mobile phone results were compared with a scientific CCD. The spatial resolution of CCD system was consistently superior to the phone, and green phone camera pixels showed better resolution than blue or green channels. The CCD exhibited similar sensitivity as processed red and blue pixels channels, yet a greater degree of detection linearity. Raw phone pixel data showed lower sensitivity but greater linearity than processed data. Overall, both qualitative and quantitative results provided strong evidence of the potential of phone-based NIR imaging, which may lead to a wide range of applications from cancer detection to glucose sensing.

  14. Transit time dispersion in pulmonary and systemic circulation: effects of cardiac output and solute diffusivity.

    Science.gov (United States)

    Weiss, Michael; Krejcie, Tom C; Avram, Michael J

    2006-08-01

    We present an in vivo method for analyzing the distribution kinetics of physiological markers into their respective distribution volumes utilizing information provided by the relative dispersion of transit times. Arterial concentration-time curves of markers of the vascular space [indocyanine green (ICG)], extracellular fluid (inulin), and total body water (antipyrine) measured in awake dogs under control conditions and during phenylephrine or isoproterenol infusion were analyzed by a recirculatory model to estimate the relative dispersions of transit times across the systemic and pulmonary circulation. The transit time dispersion in the systemic circulation was used to calculate the whole body distribution clearance, and an interpretation is given in terms of a lumped organ model of blood-tissue exchange. As predicted by theory, this relative dispersion increased linearly with cardiac output, with a slope that was inversely related to solute diffusivity. The relative dispersion of the flow-limited indicator antipyrine exceeded that of ICG (as a measure of intravascular mixing) only slightly and was consistent with a diffusional equilibration time in the extravascular space of approximately 10 min, except during phenylephrine infusion, which led to an anomalously high relative dispersion. A change in cardiac output did not alter the heterogeneity of capillary transit times of ICG. The results support the view that the relative dispersions of transit times in the systemic and pulmonary circulation estimated from solute disposition data in vivo are useful measures of whole body distribution kinetics of indicators and endogenous substances. This is the first model that explains the effect of flow and capillary permeability on whole body distribution of solutes without assuming well-mixed compartments.

  15. The Role of Intraoperative Cerebral Angiography in Transorbital Intracranial Penetrating Trauma: A Case Report and Literature Review.

    Science.gov (United States)

    Riley, Jonathan P; Boucher, Andrew B; Kim, Denise S; Barrow, Daniel L; Reynolds, Matthew R

    2017-01-01

    Transorbital intracranial penetrating trauma with a retained intracranial foreign body is a rare event lacking a widely accepted diagnostic and therapeutic algorithm. Intraoperative catheter angiography (IOA) has been advocated by some authorities to rule out cerebrovascular injury before and/or after removal of the object, but no standard of care currently exists. A 19-year-old man was involved in a construction site accident whereby a framing nail penetrated the left globe, traversed the lateral bony orbit, and terminated in the midtemporal lobe. No hematoma or injury to the middle cerebral arteries (MCAs) was apparent on noncontrast head computed tomography (CT) or CT angiography, respectively. The foreign body was removed in the operating room under direct visualization after a frontotemporal craniotomy without incident. No significant venous or arterial bleeding was encountered. All visualized MCA branches appeared intact. Indocyanine green videoangiography performed immediately after object removal showed adequate filling of the MCA branches. Given these uneventful clinical and radiographic findings, IOA was not performed. Postoperative head CT and CT angiography showed no obvious neurovascular injury. On postoperative day 2, the patient was noted to have an expressive aphasia. Cerebral angiography showed absent antegrade filling of the angular artery with some retrograde perfusion. Magnetic resonance imaging confirmed an ischemic infarction in the midtemporal lobe. The patient's expressive aphasia improved to near baseline during his hospitalization and he made an excellent clinical recovery. In transorbital intracranial penetrating trauma with a retained intracranial object, we advocate microsurgical removal of the object under direct visualization followed immediately by IOA. IOA should be strongly considered even in the setting of minimal intraoperative bleeding and normal findings on videoangiography (a course of action that was not followed in the

  16. Cardiac function and perfusion dynamics measured on a beat-by-beat basis in the live mouse using ultra-fast 4D optoacoustic imaging

    Science.gov (United States)

    Ford, Steven J.; Deán-Ben, Xosé L.; Razansky, Daniel

    2015-03-01

    The fast heart rate (~7 Hz) of the mouse makes cardiac imaging and functional analysis difficult when studying mouse models of cardiovascular disease, and cannot be done truly in real-time and 3D using established imaging modalities. Optoacoustic imaging, on the other hand, provides ultra-fast imaging at up to 50 volumetric frames per second, allowing for acquisition of several frames per mouse cardiac cycle. In this study, we combined a recently-developed 3D optoacoustic imaging array with novel analytical techniques to assess cardiac function and perfusion dynamics of the mouse heart at high, 4D spatiotemporal resolution. In brief, the heart of an anesthetized mouse was imaged over a series of multiple volumetric frames. In another experiment, an intravenous bolus of indocyanine green (ICG) was injected and its distribution was subsequently imaged in the heart. Unique temporal features of the cardiac cycle and ICG distribution profiles were used to segment the heart from background and to assess cardiac function. The 3D nature of the experimental data allowed for determination of cardiac volumes at ~7-8 frames per mouse cardiac cycle, providing important cardiac function parameters (e.g., stroke volume, ejection fraction) on a beat-by-beat basis, which has been previously unachieved by any other cardiac imaging modality. Furthermore, ICG distribution dynamics allowed for the determination of pulmonary transit time and thus additional quantitative measures of cardiovascular function. This work demonstrates the potential for optoacoustic cardiac imaging and is expected to have a major contribution toward future preclinical studies of animal models of cardiovascular health and disease.

  17. Prospective evaluation of subretinal vessel location in polypoidal choroidal vasculopathy (PCV) and response of hemorrhagic and exudative PCV to high-dose antiangiogenic therapy (an American Ophthalmological Society thesis).

    Science.gov (United States)

    Kokame, Gregg T

    2014-07-01

    The purpose of this study was to determine the following: (1) Is polypoidal choroidal vasculopathy (PCV) a subretinal neovascular process, rather than a choroidal vascular anomaly? and (2) Is a higher dose of ranibizumab (2.0 mg/0.05 mL) more effective in treating PCV than the current dose (0.5 mg/0.05 mL) approved for treatment of age-related macular degeneration? Retrospective evaluation of PCV in 104 eyes of 86 patients was accomplished with use of indocyanine green angiography plus optical coherence tomography to localize the branching vascular network and the polyps. Nineteen eyes of 19 patients with active leaking and exudation underwent a prospective open-label trial of monthly high-dose intravitreal ranibizumab (2.0 mg/0.05 mL). The primary outcome was prevention of major vision loss (≤15 ETDRS letters). Secondary outcomes included adverse events, improved vision, and changes in subretinal hemorrhage, subretinal fluid, macular edema, and polypoidal complexes at 6 months. The PCV vessels were localized beneath the retinal pigment epithelium (RPE) and above Bruch's membrane in 103 (99%) of 104 eyes. In the high-dose ranibizumab trial at 6 months, none of the patients lost ≥15 letters in visual acuity, and 5 (26%) of 19 gained ≥15 letters. Decreases were noted in subretinal fluid in 14 (82%) of 17 eyes, subretinal hemorrhage in 12 (100%) of 12, RPE detachment in 14 (88%) of 16, macular edema in 11 (92%) of 12, and polyps in 15 (79%) of 19 eyes. PCV vessels are a subtype of subretinal neovascularization located above Bruch's membrane and below RPE. High-dose ranibizumab (2.0 mg/0.05 mL) decreased exudation and hemorrhage and resulted in significant polyp regression, although branching vascular networks persisted.

  18. Critical role of oxygen radicals in the initiation of hepatic depression after trauma hemorrhage.

    Science.gov (United States)

    Jarrar, D; Wang, P; Cioffi, W G; Bland, K I; Chaudry, I H

    2000-11-01

    Although depression in hepatocellular function occurs early after trauma and severe hemorrhage and persists despite fluid resuscitation, it remains unknown whether reactive oxygen species (ROS) play any role in the initiation of hepatocellular depression and damage under those conditions. We hypothesized that administration of a ROS scavenger at the beginning of resuscitation will attenuate organ injury after severe shock. Male Sprague-Dawley rats (275-325 g) underwent laparotomy (i.e., induction of soft tissue trauma) and were then bled to and maintained at a mean arterial pressure of 40 mm Hg until 40% of the maximal bleed-out volume was returned in the form of Ringer's lactate. The animals were then resuscitated with four times the volume of maximal bleed-out with RL over 60 minutes. The ROS scavenger 2-mercaptopropionyl glycine (30 mg/kg) or vehicle was administered intravenously as a bolus at the beginning of resuscitation. At 2 hours after the completion of crystalloid resuscitation or the equivalent interval after sham-operation, cardiac index was measured by a dye dilution technique. Hepatocellular function, i.e., the maximum velocity of indocyanine green clearance (Vmax) and the efficiency of the active transport (Km), was determined using an in vivo hemoreflectometer. Serum levels of tumor necrosis factor (TNF)-alpha and alanine aminotransferase were determined with ELISA and colorimetrically, respectively. The results indicate that at 2 hours after trauma hemorrhage and resuscitation, cardiac index and hepatocellular function were markedly depressed with concomitantly increased serum levels of TNF-alpha and alanine aminotransferase (p hepatic function and markedly attenuated liver enzyme release and serum levels of TNF-alpha (p trauma hemorrhage and resuscitation.

  19. Is gut the "motor" for producing hepatocellular dysfunction after trauma and hemorrhagic shock?

    Science.gov (United States)

    Wang, P; Ba, Z F; Cioffi, W G; Bland, K I; Chaudry, I H

    1998-02-01

    Although studies suggest that the gut may be the "motor" responsible for producing sepsis and multiple organ failure after injury, it is not known whether enterectomy prior to the onset of hemorrhage alters proinflammatory cytokines TNF and IL-6 and, if so, whether hepatocellular dysfunction and damage are prevented or attenuated under such conditions. Under methoxyflurane anesthesia, an enterectomy in the rat was performed by excision of the duodenum, jejunum, and ileum. The rats were then bled to and maintained at a mean arterial pressure of 40 mm Hg until 40% of the maximal shed volume was returned in the form of Ringer's lactate. The animals were then resuscitated with four times the volume of shed blood with Ringer's lactate over 1 h. At 1.5 h after the completion of resuscitation, hepatocellular function [i.e., the maximal velocity (Vmax) and transport efficiency (Km) of indocyanine green (ICG) clearance] was assessed by an in vivo ICG clearance technique. Blood samples were taken for the measurement of TNF, IL-6, and liver enzymes (i.e., SGPT and SGOT). Cardiac output and microvascular blood flow were determined by ICG dilution and laser Doppler flowmetry, respectively. The increase in circulating levels of TNF but not IL-6 was prevented by enterectomy prior to hemorrhage. The reduced Vmax and K(m) and elevated SGPT and SGOT following hemorrhage and resuscitation, however, were not significantly affected by prior enterectomy. Moreover, enterectomy before hemorrhage further reduced hepatic perfusion. Since enterectomy prior to the onset of hemorrhage does not prevent or attenuate the reduced ICG clearance and elevated liver enzymes despite downregulation of TNF production, it appears that the small intestine does not play a significant role in producing hepatocellular dysfunction and injury following trauma and hemorrhagic shock.

  20. Chronic resuscitation after trauma-hemorrhage and acute fluid replacement improves hepatocellular function and cardiac output.

    Science.gov (United States)

    Remmers, D E; Wang, P; Cioffi, W G; Bland, K I; Chaudry, I H

    1998-01-01

    To determine whether prolonged (chronic) resuscitation has any beneficial effects on cardiac output and hepatocellular function after trauma-hemorrhage and acute fluid replacement. Acute fluid resuscitation after trauma-hemorrhage restores but does not maintain the depressed hepatocellular function and cardiac output. Male Sprague-Dawley rats underwent a 5-cm laparotomy (i.e., trauma was induced) and were bled to and maintained at a mean arterial pressure of 40 mmHg until 40% of maximal bleed-out volume was returned in the form of Ringer's lactate (RL). The animals were acutely resuscitated with RL using 4 times the volume of maximum bleed-out over 60 minutes, followed by chronic resuscitation of 0, 5, or 10 mL/kg/hr RL for 20 hours. Hepatocellular function was determined by an in vivo indocyanine green clearance technique. Hepatic microvascular blood flow was assessed by laser Doppler flowmetry. Plasma levels of interleukin-6 (IL-6) were determined by bioassay. Chronic resuscitation with 5 mL/kg/hr RL, but not with 0 or 10 mL/kg/hr RL, restored cardiac output, hepatocellular function, and hepatic microvascular blood flow at 20 hours after hemorrhage. The regimen above also reduced plasma IL-6 levels. Because chronic resuscitation with 5 mL/kg/hr RL after trauma-hemorrhage and acute fluid replacement restored hepatocellular function and hepatic microvascular blood flow and decreased plasma levels of IL-6, we propose that chronic fluid resuscitation in addition to acute fluid replacement should be routinely used in experimental studies of trauma-hemorrhage.

  1. Testosterone receptor blockade after trauma-hemorrhage improves cardiac and hepatic functions in males.

    Science.gov (United States)

    Remmers, D E; Wang, P; Cioffi, W G; Bland, K I; Chaudry, I H

    1997-12-01

    Although studies have shown that testosterone receptor blockade with flutamide after hemorrhage restores the depressed immune function, it remains unknown whether administration of flutamide following trauma and hemorrhage and resuscitation has any salutary effects on the depressed cardiovascular and hepatocellular functions. To study this, male rats underwent a laparotomy (representing trauma) and were then bled and maintained at a mean arterial pressure (MAP) of 40 mmHg until the animals could not maintain this pressure. Ringer lactate was given to maintain a MAP of 40 mmHg until 40% of the maximal shed blood volume was returned in the form of Ringer lactate. The rats were then resuscitated with four times the shed blood volume in the form of Ringer lactate over 60 min. Flutamide (25 mg/kg) or an equal volume of the vehicle propanediol was injected subcutaneously 15 min before the end of resuscitation. Various in vivo heart performance parameters (e.g., maximal rate of the pressure increase or decrease), cardiac output, and hepatocellular function (i.e., the maximum velocity and the overall efficiency of indocyanine green clearance) were determined at 20 h after resuscitation. Additionally, hepatic microvascular blood flow (HMBF) was determined using a laser Doppler flowmeter. The results indicate that left ventricular performance, cardiac output, HMBF, and hepatocellular function decreased significantly at 20 h after the completion of trauma, hemorrhage, and resuscitation. Administration of the testosterone receptor blocker flutamide, however, significantly improved cardiac performance, HMBF, and hepatocellular function. Thus flutamide appears to be a novel and useful adjunct for improving cardiovascular and hepatocellular functions in males following trauma and hemorrhagic shock.

  2. Dehydroepiandrosterone restores hepatocellular function and prevents liver damage in estrogen-deficient females following trauma and hemorrhage.

    Science.gov (United States)

    Kuebler, J F; Jarrar, D; Wang, P; Bland, K I; Chaudry, I H

    2001-05-15

    Recent studies have shown that administration of the sex steroid dehydroepiandrosterone (DHEA) in males following trauma-hemorrhagic shock has salutary effects on the depressed cardiovascular and immunological functions under those conditions. Since the effects of sex steroids are gender specific, we examined whether administration of DHEA has any beneficial effects on hepatocellular function in female rats with low estrogen levels following trauma-hemorrhage. Ovariectomy was performed in female Sprague-Dawley rats 14 days prior to the experiments. The animals then underwent a 5-cm midline laparotomy and were subjected to hemorrhagic shock (40 mm Hg for 90 min). This was followed by fluid resuscitation (Ringer's lactate over 60 min) and administration of DHEA (30 mg/kg BW) or vehicle subcutaneously at the end of resuscitation. At 24 h after resuscitation hepatocellular function, i.e., clearance of indocyanine green (ICG), and hepatocyte damage (serum alanine aminotransferase) were measured. Plasma levels of DHEA and 17beta-estradiol were also assayed. Vehicle-treated rats had significantly reduced hepatocellular function, increased ALT activity, and decreased levels of 17beta-estradiol following trauma-hemorrhage compared to sham-operated animals (P trauma-hemorrhage, hepatocellular function and ALT activity were similar to those of shams. However, administration of DHEA did not influence the plasma levels of 17beta-estradiol. Administration of DHEA following trauma-hemorrhage restored hepatocellular function and reduced hepatic damage that was observed in ovariectomized female rats under such conditions. This salutary effect of DHEA did not appear to be due to elevated levels of plasma 17beta-estradiol. We therefore propose that DHEA should be considered a novel, safe, and useful adjunct in the treatment of trauma-induced hepatocellular dysfunction in ovariectomized and postmenopausal females. Copyright 2001 Academic Press.

  3. Kupffer cell ablation attenuates cyclooxygenase-2 expression after trauma and sepsis.

    Science.gov (United States)

    Keller, Steve A; Paxian, Marcus; Lee, Sun M; Clemens, Mark G; Huynh, Toan

    2005-03-01

    Prostaglandins, synthesized by cyclooxygenase (COX), play an important role in the pathophysiology of inflammation. Severe injuries result in immunosuppression, mediated, in part, by maladaptive changes in macrophages. Herein, we assessed Kupffer cell-mediated cyclooxygenase-2 (COX-2) expression on liver function and damage after trauma and sepsis. To ablate Kupffer cells, Sprague Dawley rats were treated with gadolinium chloride (GdCl3) 48 and 24 h before experimentation. Animals then underwent femur fracture (FFx) followed 48 h later by cecal ligation and puncture (CLP). Controls received sham operations. After 24 h, liver samples were obtained, and mRNA and protein expression were determined by PCR, Western blot, and immunohistochemistry. Indocyanine-Green (ICG) clearance and plasma alanine aminotransferase (ALT) levels were determined to assess liver function and damage, respectively. One-way analysis of variance (ANOVA) with Student-Newman-Keuls test was used to assess statistical significance. After CLP alone, FFx+CLP, and GdCl3+FFx+CLP, clearance of ICG decreased. Plasma ALT levels increased in parallel with severity of injury. Kupffer cell depletion attenuated the increased ALT levels after FFx+CLP. Femur fracture alone did not alter COX-2 protein compared with sham. By contrast, COX-2 protein increased after CLP and was potentiated by sequential stress. Again, Kupffer cell depletion abrogated the increase in COX-2 after sequential stress. Immunohistochemical data confirmed COX-2 positive cells to be Kupffer cells. In this study, sequential stress increased hepatic COX-2 protein. Depletion of Kupffer cells reduced COX-2 and attenuated hepatocellular injuries. Our data suggest that Kupffer cell-dependent pathways may contribute to the inflammatory response leading to increased mortality after sequential stress.

  4. Hepatic drug clearance following traumatic injury.

    Science.gov (United States)

    Slaughter, R L; Hassett, J M

    1985-11-01

    Trauma is a complex disease state associated with physiologic changes that have the potential to alter hepatic drug clearance mechanisms. These responses include alterations in hepatic blood flow, reduction in hepatic microsomal activity, reduction in hepatic excretion processes, and changes in protein binding. Hepatic blood flow is influenced by sympathomimetic activity. Both animal and human studies demonstrate an initial reduction and subsequent increase in hepatic blood flow, which coincides with an observed increase and subsequent return to normal in serum catecholamine concentrations. Unfortunately, there are no human studies that address the importance these findings may have to the clearance processes of high intrinsic clearance compounds. Animal studies of trauma indicate that hepatic microsomal activity is depressed during the post-traumatic period. Reduction in the hepatic clearance of antipyrine, a model low intrinsic compound, has also been demonstrated in animal models of trauma. In addition to these effects, hepatic excretion of substances such as indocyanine green and bilirubin have been demonstrated to be impaired in both traumatized animals and humans. Finally, substantial increases in the serum concentration of the binding protein alpha 1-acid glycoprotein occur in trauma patients. This has been reported to be associated with subsequent decreases in the free fraction of lidocaine and quinidine. In addition to changing serum drug concentration/response relationships, the pharmacokinetic behavior of drugs bound to alpha 1-acid glycoprotein should also change. Preliminary observations in our laboratory in a dog model of surgically-induced trauma have shown a reduction in the total clearance of lidocaine and reduction in free lidocaine concentration.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Estradiol improves cardiac and hepatic function after trauma-hemorrhage: role of enhanced heat shock protein expression.

    Science.gov (United States)

    Szalay, László; Shimizu, Tomoharu; Suzuki, Takao; Yu, Huang-Ping; Choudhry, Mashkoor A; Schwacha, Martin G; Rue, Loring W; Bland, Kirby I; Chaudry, Irshad H

    2006-03-01

    Although studies indicate that 17beta-estradiol administration after trauma-hemorrhage (T-H) improves cardiac and hepatic functions, the underlying mechanisms remain unclear. Because the induction of heat shock proteins (HSPs) can protect cardiac and hepatic functions, we hypothesized that these proteins contribute to the salutary effects of estradiol after T-H. To test this hypothesis, male Sprague-Dawley rats ( approximately 300 g) underwent laparotomy and hemorrhagic shock (35-40 mmHg for approximately 90 min) followed by resuscitation with four times the shed blood volume in the form of Ringer lactate. 17beta-estradiol (1 mg/kg body wt) was administered at the end of the resuscitation. Five hours after T-H and resuscitation there was a significant decrease in cardiac output, positive and negative maximal rate of left ventricular pressure. Liver function as determined by bile production and indocyanine green clearance was also compromised after T-H and resuscitation. This was accompanied by an increase in plasma alanine aminotransferase (ALT) levels and liver perfusate lactic dehydrogenase levels. Furthermore, circulating levels of TNF-alpha, IL-6, and IL-10 were also increased. In addition to decreased cardiac and hepatic function, there was an increase in cardiac HSP32 expression and a reduction in HSP60 expression after T-H. In the liver, HSP32 and HSP70 were increased after T-H. There was no change in heart HSP70 and liver HSP60 after T-H and resuscitation. Estradiol administration at the end of T-H and resuscitation increased heart/liver HSPs expression, ameliorated the impairment of heart/liver functions, and significantly prevented the increase in plasma levels of ALT, TNF-alpha, and IL-6. The ability of estradiol to induce HSPs expression in the heart and the liver suggests that HSPs, in part, mediate the salutary effects of 17beta-estradiol on organ functions after T-H.

  6. Detecting thermal phase transitions in corneal stroma by fluorescence micro-imaging analysis

    Science.gov (United States)

    Matteini, P.; Rossi, F.; Ratto, F.; Bruno, I.; Nesi, P.; Pini, R.

    2008-02-01

    Thermal modifications induced in corneal stroma were investigated by the use of fluorescence microscopy. Freshly extracted porcine corneas were immersed for 5 minutes in a water bath at temperatures in the 35-90°C range and stored in formalin. The samples were then sliced in 200-μm-thick transversal sections and analyzed under a stereomicroscope to assess corneal shrinkage. Fluorescence images of the thermally treated corneal samples were acquired using a slow-scan cooled CCD camera, after staining the slices with Indocyanine Green (ICG) fluorescent dye which allowed to detect fluorescence signal from the whole tissue. All measurements were performed using an inverted epifluorescence microscope equipped with a mercury lamp. The thermally-induced modifications to the corneal specimens were evaluated by studying the grey level distribution in the fluorescence images. For each acquired image, Discrete Fourier Transform (DFT) and entropy analyses were performed. The spatial distribution of DFT absolute value indicated the spatial orientation of the lamellar planes, while entropy was used to study the image texture, correlated to the stromal structural transitions. As a result, it was possible to indicate a temperature threshold value (62°C) for high thermal damage, resulting in a disorganization of the lamellar planes and in full agreement with the measured temperature for corneal shrinkage onset. Analysis of the image entropy evidenced five strong modifications in stromal architecture at temperatures of ~45°C, 53°C, 57°C, 66°C, 75°C. The proposed procedure proved to be an effective micro-imaging method capable of detecting subtle changes in corneal tissue subjected to thermal treatment.

  7. Efficacy of liver parenchymal enhancement and liver volume to standard liver volume ratio on Gd-EOB-DTPA-enhanced MRI for estimation of liver function

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, Tomohide; Fukukura, Yoshihiko; Kamimura, Kiyohisa; Takumi, Koji; Umanodan, Aya; Nakajo, Masayuki [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Radiology, Kagoshima City (Japan); Ueno, Shinichi [Kagoshima University Graduate School of Medical and Dental Sciences, Department of Surgical Oncology and Digestive Surgery, Kagoshima City (Japan)

    2014-04-15

    We aimed to develop and assess the efficacy of a liver function index that combines liver enhancement and liver volume to standard liver volume (LV/SLV) ratio on gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA)-enhanced MRI. In all, 111 patients underwent a Gd-EOB-DTPA-enhanced MRI, including T1 mapping, before and 20 min after Gd-EOB-DTPA administration. We calculated the following Gd-EOB-DTPA-enhanced MRI-based liver function indices: relative enhancement of the liver, corrected enhancement of the liver-to-spleen ratio, LSC{sub N}20, increase rate of the liver-to-muscle ratio, reduction rate of T1 relaxation time of the liver, ΔR1 of the liver and K{sub Hep}; the indices were multiplied by the LV/SLV ratio. We calculated the correlations between an indocyanine green (ICG) clearance and the Gd-EOB-DTPA-enhanced MRI-based liver function indices multiplied by the LV/SLV ratio, by using Pearson correlation analysis. There were significant correlations between all Gd-EOB-DTPA-enhanced MRI-based liver function indices and ICG clearance (r = -0.354 to -0.574, P < 0.001). All Gd-EOB-DTPA-enhanced MRI-based liver function indices multiplied by the LV/SLV ratio (r = -0.394 to -0.700, P < 0.001) were more strongly correlated with the ICG clearance than those without multiplication by the LV/SLV ratio. Gd-EOB-DTPA-enhanced MRI-based liver function indices that combine liver enhancement and the LV/SLV ratio may more reliably estimate liver function. (orig.)

  8. A surgical navigation system for non-contact diffuse optical tomography and intraoperative cone-beam CT

    Science.gov (United States)

    Daly, Michael J.; Muhanna, Nidal; Chan, Harley; Wilson, Brian C.; Irish, Jonathan C.; Jaffray, David A.

    2014-02-01

    A freehand, non-contact diffuse optical tomography (DOT) system has been developed for multimodal imaging with intraoperative cone-beam CT (CBCT) during minimally-invasive cancer surgery. The DOT system is configured for near-infrared fluorescence imaging with indocyanine green (ICG) using a collimated 780 nm laser diode and a nearinfrared CCD camera (PCO Pixelfly USB). Depending on the intended surgical application, the camera is coupled to either a rigid 10 mm diameter endoscope (Karl Storz) or a 25 mm focal length lens (Edmund Optics). A prototype flatpanel CBCT C-Arm (Siemens Healthcare) acquires low-dose 3D images with sub-mm spatial resolution. A 3D mesh is extracted from CBCT for finite-element DOT implementation in NIRFAST (Dartmouth College), with the capability for soft/hard imaging priors (e.g., segmented lymph nodes). A stereoscopic optical camera (NDI Polaris) provides real-time 6D localization of reflective spheres mounted to the laser and camera. Camera calibration combined with tracking data is used to estimate intrinsic (focal length, principal point, non-linear distortion) and extrinsic (translation, rotation) lens parameters. Source/detector boundary data is computed from the tracked laser/camera positions using radiometry models. Target registration errors (TRE) between real and projected boundary points are ~1-2 mm for typical acquisition geometries. Pre-clinical studies using tissue phantoms are presented to characterize 3D imaging performance. This translational research system is under investigation for clinical applications in head-and-neck surgery including oral cavity tumour resection, lymph node mapping, and free-flap perforator assessment.

  9. Liver stiffness value-based risk estimation of late recurrence after curative resection of hepatocellular carcinoma: development and validation of a predictive model.

    Directory of Open Access Journals (Sweden)

    Kyu Sik Jung

    Full Text Available Preoperative liver stiffness (LS measurement using transient elastography (TE is useful for predicting late recurrence after curative resection of hepatocellular carcinoma (HCC. We developed and validated a novel LS value-based predictive model for late recurrence of HCC.Patients who were due to undergo curative resection of HCC between August 2006 and January 2010 were prospectively enrolled and TE was performed prior to operations by study protocol. The predictive model of late recurrence was constructed based on a multiple logistic regression model. Discrimination and calibration were used to validate the model.Among a total of 139 patients who were finally analyzed, late recurrence occurred in 44 patients, with a median follow-up of 24.5 months (range, 12.4-68.1. We developed a predictive model for late recurrence of HCC using LS value, activity grade II-III, presence of multiple tumors, and indocyanine green retention rate at 15 min (ICG R15, which showed fairly good discrimination capability with an area under the receiver operating characteristic curve (AUROC of 0.724 (95% confidence intervals [CIs], 0.632-0.816. In the validation, using a bootstrap method to assess discrimination, the AUROC remained largely unchanged between iterations, with an average AUROC of 0.722 (95% CIs, 0.718-0.724. When we plotted a calibration chart for predicted and observed risk of late recurrence, the predicted risk of late recurrence correlated well with observed risk, with a correlation coefficient of 0.873 (P<0.001.A simple LS value-based predictive model could estimate the risk of late recurrence in patients who underwent curative resection of HCC.

  10. Nonclinical Profile of BLZ-100, a Tumor-Targeting Fluorescent Imaging Agent.

    Science.gov (United States)

    Parrish-Novak, Julia; Byrnes-Blake, Kelly; Lalayeva, Narine; Burleson, Stefanie; Fidel, Janean; Gilmore, Rhonda; Gayheart-Walsten, Pamela; Bricker, Gregory A; Crumb, William J; Tarlo, K S; Hansen, Stacey; Wiss, Valorie; Malta, Errol; Dernell, William S; Olson, James M; Miller, Dennis M

    BLZ-100 is a single intravenous use, fluorescent imaging agent that labels tumor tissue to enable more complete and precise surgical resection. It is composed of a chlorotoxin peptide covalently bound to the near-infrared fluorophore indocyanine green. BLZ-100 is in clinical development for intraoperative visualization of human tumors. The nonclinical safety and pharmacokinetic (PK) profile of BLZ-100 was evaluated in mice, rats, canines, and nonhuman primates (NHP). Single bolus intravenous administration of BLZ-100 was well tolerated, and no adverse changes were observed in cardiovascular safety pharmacology, PK, and toxicology studies in rats and NHP. The single-dose no-observed-adverse-effect-levels (NOAELs) were 7 mg (28 mg/kg) in rats and 60 mg (20 mg/kg) in NHP, corresponding to peak concentration values of 89 400 and 436 000 ng/mL and area-under-the-curve exposure values of 130 000 and 1 240 000 h·ng/mL, respectively. Based on a human imaging dose of 3 mg, dose safety margins are >100 for rat and monkey. BLZ-100 produced hypersensitivity reactions in canine imaging studies (lethargy, pruritus, swollen muzzle, etc). The severity of the reactions was not dose related. In a follow-up study in dogs, plasma histamine concentrations were increased 5 to 60 minutes after BLZ-100 injection; this coincided with signs of hypersensitivity, supporting the conclusion that the reactions were histamine based. Hypersensitivity reactions were not observed in other species or in BLZ-100 human clinical studies conducted to date. The combined imaging, safety pharmacology, PK, and toxicology studies contributed to an extensive initial nonclinical profile for BLZ-100, supporting first-in-human clinical trials.

  11. Importance of intrahepatic mechanisms to gluconeogenesis from alanine during exercise and recovery

    International Nuclear Information System (INIS)

    Wasserman, D.H.; Williams, P.E.; Lacy, D.B.; Green, D.R.; Cherrington, A.D.

    1988-01-01

    These studies were performed to assess the importance of intrahepatic mechanisms to gluconeogenesis in the dog during 150 min of treadmill exercise and 90 min of recovery. Sampling catheters were implanted in an artery and portal and hepatic veins 16 days before experimentation. Infusions of [U- 14 C]alanine, [3- 3 H]glucose, and indocyanine green were used to assess gluconeogenesis. During exercise, a decline in arterial and portal vein plasma alanine and in hepatic blood flow led to a decrease in hepatic alanine delivery. During recovery, hepatic blood flow was restored to basal, causing an increase in hepatic alanine delivery beyond exercise rates but still below resting rates. Hepatic fractional alanine extraction increased from 0.26 +/- 0.02 at rest to 0.64 +/- 0.03 during exercise and remained elevated during recovery. Net hepatic alanine uptake was 2.5 +/- 0.2 mumol.kg-1.min-1 at rest and remained unchanged during exercise but was increased during recovery. The conversion rate of [ 14 C]alanine to glucose had increased by 248 +/- 38% by 150 min of exercise and had increased further during recovery. The efficiency with which alanine was channeled into glucose in the liver was accelerated to a rate of 338 +/- 55% above basal by 150 min of exercise but declined slightly during recovery. In conclusion, 1) gluconeogenesis from alanine is accelerated during exercise, due to an increase in the hepatic fractional extraction of the amino acid and through intrahepatic mechanisms that more efficiently channel it into glucose

  12. Effects of chlorphentermine and phentermine on the pulmonary disposition of 5-hydroxytryptamine in the rat in vivo

    International Nuclear Information System (INIS)

    Morita, T.; Mehendale, H.M.

    1983-01-01

    This study was designed to examine whether chlorphentermine (CP) affects pulmonary disposition of 5-hydroxytryptamine (5-HT) in rat in vivo. Further, the effects of CP were compared with those of phentermine (P), the nonchlorinated congener. The right jugular vein and left carotid artery of male Sprague-Dawley rats were cannulated and fresh saline solution containing 150 micrograms indocyanine green and a mixture of labeled and unlabeled 5-HT was injected into the jugular vein, and arterial blood samples were collected for 20 s. In order to compare the effect of CP and P on pulmonary disposition of 5-HT, 2.6 nmol [ 14 C]-5-HT was employed for in vivo single-pass experiments. Each animal was used for 2 in vivo single-pass experiments. After the first experiment, which served as a control, animals received an indicated dose of CP or P, to commence the second ''drug-treated'' in vivo experiment. Pulmonary clearance of 5-HT was inhibited by prior administration of CP (1 mg/kg) by 42%, whereas at the highest dose (20 mg/kg) P inhibited 5-HT clearance by only 25%. Pulmonary accumulation of CP was greater than P at higher doses, and the inhibition of 5-HT clearance correlated with the pulmonary accumulation of these drugs. In addition to the in vivo demonstration of the CP inhibition of pulmonary clearance of 5-HT in the rat, these studies also demonstrate a higher affinity of the lung tissue for CP than for P and a greater propensity for the impairment of pulmonary 5-HT clearance

  13. Pure 3D laparoscopic living donor right hemihepatectomy in a donor with separate right posterior and right anterior hepatic ducts and portal veins.

    Science.gov (United States)

    Hong, Suk Kyun; Suh, Kyung-Suk; Kim, Hyo-Sin; Yoon, Kyung Chul; Ahn, Sung-Woo; Oh, Dongkyu; Kim, Hyeyoung; Yi, Nam-Joon; Lee, Kwang-Woong

    2017-11-01

    Despite increases in the performance of pure laparoscopic living donor hepatectomy, variations in the bile duct or portal vein have been regarded as relative contraindications to this technique [1-3]. This report describes a donor with separate right posterior and right anterior hepatic ducts and portal veins who underwent pure laparoscopic living donor right hemihepatectomy, integrated with 3D laparoscopy and indocyanine green (ICG) near-infrared fluorescence cholangiography [1, 4, 5]. A 50-year-old man offered to donate part of his liver to his older brother, who required a transplant for hepatitis B-associated liver cirrhosis and hepatocellular carcinoma. Donor height was 178.0 cm, body weight was 82.7 kg, and body mass index was 26.1 kg/m 2 . Preoperative computed tomography and magnetic resonance cholangiopancreatography showed that the donor had separate right posterior and right anterior hepatic ducts and portal veins. The entire procedure was performed under 3D laparoscopic view. Following intravenous injections of 0.05 mg/kg ICG, ICG near-infrared fluorescence camera was used to demarcate the exact transection line and determine the optimal bile duct division point. The total operation time was 443 min; the donor required no transfusions and experienced no intraoperative complications. The graft weighed 1146 g with a graft-to-recipient weight ratio of 1.88%. The optimal bile duct division point was identified using ICG fluorescence cholangiography, and the bile duct was divided with good patency without any stricture. The right anterior and posterior portal veins were transected with endostaplers without any torsion. The patient was discharged on postoperative day 8, with no complications. Using a 3D view and ICG fluorescence cholangiography, pure 3D laparoscopic living donor right hemihepatectomy is feasible in a donor with separate right posterior and right anterior hepatic ducts and portal veins.

  14. Dynamic and accurate assessment of acetaminophen-induced hepatotoxicity by integrated photoacoustic imaging and mechanistic biomarkers in vivo.

    Science.gov (United States)

    Brillant, Nathalie; Elmasry, Mohamed; Burton, Neal C; Rodriguez, Josep Monne; Sharkey, Jack W; Fenwick, Stephen; Poptani, Harish; Kitteringham, Neil R; Goldring, Christopher E; Kipar, Anja; Park, B Kevin; Antoine, Daniel J

    2017-10-01

    The prediction and understanding of acetaminophen (APAP)-induced liver injury (APAP-ILI) and the response to therapeutic interventions is complex. This is due in part to sensitivity and specificity limitations of currently used assessment techniques. Here we sought to determine the utility of integrating translational non-invasive photoacoustic imaging of liver function with mechanistic circulating biomarkers of hepatotoxicity with histological assessment to facilitate the more accurate and precise characterization of APAP-ILI and the efficacy of therapeutic intervention. Perturbation of liver function and cellular viability was assessed in C57BL/6J male mice by Indocyanine green (ICG) clearance (Multispectral Optoacoustic Tomography (MSOT)) and by measurement of mechanistic (miR-122, HMGB1) and established (ALT, bilirubin) circulating biomarkers in response to the acetaminophen and its treatment with acetylcysteine (NAC) in vivo. We utilised a 60% partial hepatectomy model as a situation of defined hepatic functional mass loss to compared acetaminophen-induced changes to. Integration of these mechanistic markers correlated with histological features of APAP hepatotoxicity in a time-dependent manner. They accurately reflected the onset and recovery from hepatotoxicity compared to traditional biomarkers and also reported the efficacy of NAC with high sensitivity. ICG clearance kinetics correlated with histological scores for acute liver damage for APAP (i.e. 3h timepoint; r=0.90, P<0.0001) and elevations in both of the mechanistic biomarkers, miR-122 (e.g. 6h timepoint; r=0.70, P=0.005) and HMGB1 (e.g. 6h timepoint; r=0.56, P=0.04). For the first time we report the utility of this non-invasive longitudinal imaging approach to provide direct visualisation of the liver function coupled with mechanistic biomarkers, in the same animal, allowing the investigation of the toxicological and pharmacological aspects of APAP-ILI and hepatic regeneration. Copyright © 2017

  15. Blockade of Tumor Necrosis Factor-Alpha: A Role for Adalimumab in Neovascular Age-Related Macular Degeneration Refractory to Anti-Angiogenesis Therapy

    Directory of Open Access Journals (Sweden)

    Beatriz Fernández-Vega

    2016-03-01

    Full Text Available Aims: To report a case of wet age-related macular degeneration (wet-AMD refractory to intravitreal anti-vascular endothelial growth factor (anti-VEGF therapy in a patient who showed visual and anatomical improvement and stabilization after starting a subcutaneous treatment course with adalimumab, an anti-tumor necrosis factor-alpha (TNF-α drug, for concomitant Crohn's disease. Methods: Observational case report of a female patient. Ophthalmological evaluation was performed by slit lamp and ophthalmoscopy (posterior pole and anterior segment. Best-corrected visual acuity (BCVA was determined, and imaging was performed by fluorescein angiography, indocyanine green angiography, and optical coherence tomography (OCT. Intravitreal therapies used and treatment with anti-TNF-α were recorded. Results: A 64-year-old woman with wet-AMD was treated with fourteen intravitreal injections of ranibizumab (0.5 mg for a period of 40 months with intervals of 1-6 months. She initially showed a good visual and anatomical response to periodic anti-VEGF treatment but during check visits, anatomical and functional responses deteriorated. At the 40-month follow-up, the patient had developed Crohn's disease, and her rheumatologist started treatment with adalimumab (40 mg subcutaneously every 2 weeks. During the 25 months of treatment with adalimumab, the patient did not require any additional intravitreal anti-VEGF treatments because her BCVA, clinical, and OCT findings improved and remained stable. Conclusions: We described a case of a patient with wet-AMD refractory to anti-VEGF therapy, which clinically benefited from subcutaneous adalimumab therapy. Treatment with subcutaneous anti-TNF-α in combination with anti-VEGF therapy avoids the high cost and risks related to multiple intravitreal anti-VEGF injections with good functional and anatomic outcomes.

  16. Validation of ALFIA: a platform for quantifying near-infrared fluorescent images of lymphatic propulsion in humans

    Science.gov (United States)

    Rasmussen, John C.; Bautista, Merrick; Tan, I.-Chih; Adams, Kristen E.; Aldrich, Melissa; Marshall, Milton V.; Fife, Caroline E.; Maus, Erik A.; Smith, Latisha A.; Zhang, Jingdan; Xiang, Xiaoyan; Zhou, Shaohua Kevin; Sevick-Muraca, Eva M.

    2011-02-01

    Recently, we demonstrated near-infrared (NIR) fluorescence imaging for quantifying real-time lymphatic propulsion in humans following intradermal injections of microdose amounts of indocyanine green. However computational methods for image analysis are underdeveloped, hindering the translation and clinical adaptation of NIR fluorescent lymphatic imaging. In our initial work we used ImageJ and custom MatLab programs to manually identify lymphatic vessels and individual propulsion events using the temporal transit of the fluorescent dye. In addition, we extracted the apparent velocities of contractile propagation and time periods between propulsion events. Extensive time and effort were required to analyze the 6-8 gigabytes of NIR fluorescent images obtained for each subject. To alleviate this bottleneck, we commenced development of ALFIA, an integrated software platform which will permit automated, near real-time analysis of lymphatic function using NIR fluorescent imaging. However, prior to automation, the base algorithms calculating the apparent velocity and period must be validated to verify that they produce results consistent with the proof-of-concept programs. To do this, both methods were used to analyze NIR fluorescent images of two subjects and the number of propulsive events identified, the average apparent velocities, and the average periods for each subject were compared. Paired Student's t-tests indicate that the differences between their average results are not significant. With the base algorithms validated, further development and automation of ALFIA can be realized, significantly reducing the amount of user interaction required, and potentially enabling the near real-time, clinical evaluation of NIR fluorescent lymphatic imaging.

  17. Iris autofluorescence in Fuchs' heterochromic uveitis.

    Science.gov (United States)

    Liu, Qian; Jia, Yading; Zhang, Suhua; Xie, Juan; Chang, Xin; Hou, Jia; Li, Gaiyun; Koch, Douglas D; Wang, Li

    2016-10-01

    To explore the characteristic autofluorescence patterns of iris depigmentation in eyes diagnosed with Fuchs' heterochromic uveitis (FHU). Near-infrared autofluorescence images and colour images of iris were taken in 21 eyes of 21 patients with FHU, 30 eyes of 15 normal subjects, 30 eyes of 15 normal age-related iris atrophy and 33 eyes of 20 patients with uveitis other than FHU. The confocal scanning laser ophthalmoscope (Heidelberg Retina Angiograph 2, HRA2) was used for melanin-related autofluorescence imaging. The indocyanine green angiography mode of HRA2 was applied for near-infrared laser imaging, and the wavelength of the excitation laser was 795 nm. Iris colour images were also taken with the slit lamp. In normal iris, moderately intense autofluorescence was noted for the pigment ruff at the pupillary border, the crests in the pupillary zone and the collarette; and there was mild autofluorescence in the ciliary zone. In eyes with age-related iris atrophy and uveitis, much less autofluorescence was seen than the healthy normal irides. In eyes with FHU, there was moderate but discontinuous autofluorescence in the pigment ruff, a petaloid pattern of autofluorescence in the pupillary zone, moderate autofluorescence in the collarette and reticular pattern of autofluorescence in the ciliary zone. Characteristic autofluorescence patterns appeared in eyes diagnosed with FHU. Near-infrared autofluorescence is a promising objective technique to document the iris changes in FHU. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Retinal pigment epithelial changes in chronic Vogt-Koyanagi-Harada disease: fundus autofluorescence and spectral domain-optical coherence tomography findings.

    Science.gov (United States)

    Vasconcelos-Santos, Daniel V; Sohn, Elliott H; Sadda, Srinivas; Rao, Narsing A

    2010-01-01

    The purpose of this study was to determine whether fundus autofluorescence (FAF) and spectral domain-optical coherence tomography (SD-OCT) imaging allow better assessment of retinal pigment epithelium and the outer retina in subjects with chronic Vogt-Koyanagi-Harada disease compared with examination and angiography alone. A cross-sectional analysis of a series of seven consecutive patients with chronic Vogt-Koyanagi-Harada disease undergoing FAF and SD-OCT was conducted. Chronic disease was defined as duration of intraocular inflammation >3 months. Color fundus photographs were correlated to FAF and SD-OCT images. The images were later correlated to fluorescein angiography and indocyanine green angiography. All patients had sunset glow fundus, which resulted in no apparent corresponding abnormality on FAF or SD-OCT. Lesions with decreased autofluorescence signal were observed in 11 eyes (85%), being associated with loss of the retinal pigment epithelium and involvement of the outer retina on SD-OCT. In 5 eyes (38%), some of these lesions were very subtle on clinical examination but easily detected by FAF. Lesions with increased autofluorescence signal were seen in 8 eyes (61.5%), showing variable involvement of the outer retina on SD-OCT and corresponding clinically to areas of retinal pigment epithelium proliferation and cystoid macular edema. Combined use of FAF and SD-OCT imaging allowed noninvasive delineation of retinal pigment epithelium/outer retina changes in patients with chronic Vogt-Koyanagi-Harada disease, which were consistent with previous histopathologic reports. Some of these changes were not apparent on clinical examination.

  19. Characterization and functional correlation of multiple imaging modalities with focal choroidal excavation

    Directory of Open Access Journals (Sweden)

    Yun-Chen Chen

    2018-05-01

    Full Text Available Background: To investigate the clinical manifestations and imaging features of near-infrared autofluorescence (NIA, infrared reflectance (IR, fundus autofluorescence (FAF, indocyanine green angiography (ICGA and fluorescein angiography (FAG in the detection of patients with focal choroidal excavation (FCE identified by cross-sectional spectral-domain optical coherence tomography (SD-OCT. Methods: This retrospective cross-sectional study included 12 eyes of 10 Taiwanese patients with FCE diagnosed by SD-OCT. The areas and depths of FCE in serial cross-sectional and en-face OCT were compared in different imaging modalities. NIA, IR, FAF, ICGA and FAG images were obtained. Best corrected visual acuity, subjective distortion area in the Amsler grid and history of maculopathies were also recorded. Results: In areas where the choroid started to excavate as shown in SD-OCT, hypo-autofluorescence in NIA was noted. The area of hypo-fluorescence in NIA of all the FCE lesions showed good correlation with the size. The area of FCE was associated with complications such as choroidal neovascularization and central serous chorioretinopathy (p = 0.014, d.f = 1 and the volume (NIA area × Depth measured by SD-OCT × 1/3 was associated with subjective distortion strongly (p = 0.051, Spearman's correlation = 0.600. Conclusion: Among all image modalities, NIA was the most sensitive tool in area measurement of FCE and peripheral lesion detection. Also, the volume of FCE was associated with subjective distortion and the area was related to complications. Recording the area and volume of FCE could play an important role in monitoring complications. Keywords: Choroid-retina disease, Focal choroidal excavation, Near-infrared autofluorescence, Spectral-domain optical coherence tomography

  20. Characteristics of Fundus Autofluorescence in Active Polypoidal Choroidal Vasculopathy

    Directory of Open Access Journals (Sweden)

    Zafer Öztaş

    2016-08-01

    Full Text Available Objectives: To define characteristic fundus autofluorescence (FAF findings in eyes with active polypoidal choroidal vasculopathy (PCV. Materials and Methods: Thirty-five eyes of 29 patients with active PCV who were diagnosed at Ege University Faculty of Medicine, Department of Ophthalmology, Retina Division between January 2012 and November 2014 were included in the study. All the patients underwent a complete ophthalmological examination including fundus photography, spectral-domain optical coherence tomography, fluorescein angiography, FAF photography, and indocyanine green angiography (ICGA. ICGA was used to diagnose active PCV and identify lesion components. FAF findings were described at the retinal site of the corresponding lesions identified and diagnosed using ICGA. Results: The mean age of the 29 study patients (15 men, 14 women was 64.6±7.5 years (range, 54-82 years. ICGA revealed active PCV in 35 eyes, consisting of polypoid lesions in 11 eyes (31.4%, branching vascular networks (BVN in 10 eyes (28.6%, and a combination of polypoid lesions and BVNs in 14 eyes (40%. On FAF images, 4 different patterns were detected at the corresponding retinal sites of 25 polypoid lesions detected by ICGA: confluent hypoautofluorescence with a hyperautofluorescent ring in 18 eyes (72%, hyperautofluorescence with hypoautofluorescent ring in 2 eyes (8%, confluent hypoautofluorescence in 1 eye (4%, and granular hypoautofluorescence in 1 eye (4%. The remaining 3 eyes (12% demonstrated blocked hypoautofluorescence because of the excessive hemorrhaging in the macula. The FAF images showed the granular hypoautofluorescent FAF pattern in all 24 BVNs (100% consistent with the location of the lesions on ICGA. Conclusion: The typical PCV lesions, polypoid lesions and BVNs had characteristic autofluorescent findings on FAF imaging. Non-invasive, quick, and repeatable FAF imaging can be considered a reliable and helpful diagnostic technique for the diagnosis of

  1. Desgarro de epitelio pigmentario retiniano periférico idiopático Tear of the idiopathic peripheral retinal pigmentary epithelium

    Directory of Open Access Journals (Sweden)

    Raúl Reinaldo Leyva Almarales

    2011-06-01

    Full Text Available Los desgarros del epitelio pigmentario de la retina constituyen entidades asociadas a degeneración macular relacionada con la edad con desprendimiento de epitelio pigmentario retiniano. Aunque puede tener múltiples causas, también puede ser idiopático y su localización más frecuente ocurre a nivel del polo posterior retiniano. Se presenta un caso de desgarro de epitelio pigmentario retiniano periférico en paciente sin patología del polo posterior retiniano, el cual se produjo de manera espontánea y no se encontró causa alguna; se realizaron fotos de fondo de ojo a color, autofluorescencia y angiografía con verde indiocianina, que confirmaron el diagnóstico. Por su carácter infrecuente hemos decidido presentar este caso de desgarro de epitelio pigmentario de retina de localización periférica y de causa idiopática.The tears of the retina pigmentary epithelium are entities associated with a macular degeneration related to age in which occur such tears. Although it may to have multiple causes, also may be idiopathic and its more frequent location is at level of retinal posterior pole. Authors present a case of peripheral retinal pigmentary epithelium tear diagnosed in a patient without pathology or retinal posterior pole, which occurred in a spontaneous way with any cause; the fundus oculi color photos were taken, auto-fluorescence and indocyanine green confirmed diagnosis. Due to its infrequent character authors decide to present this above mentioned case and of idiopathic cause.

  2. Catheter-based time-gated near-infrared fluorescence/OCT imaging system

    Science.gov (United States)

    Lu, Yuankang; Abran, Maxime; Cloutier, Guy; Lesage, Frédéric

    2018-02-01

    We developed a new dual-modality intravascular imaging system based on fast time-gated fluorescence intensity imaging and spectral domain optical coherence tomography (SD-OCT) for the purpose of interventional detection of atherosclerosis. A pulsed supercontinuum laser was used for fluorescence and OCT imaging. A double-clad fiber (DCF)- based side-firing catheter was designed and fabricated to have a 23 μm spot size at a 2.2 mm working distance for OCT imaging. Its single-mode core is used for OCT, while its inner cladding transports fluorescence excitation light and collects fluorescent photons. The combination of OCT and fluorescence imaging was achieved by using a DCF coupler. For fluorescence detection, we used a time-gated technique with a novel single-photon avalanche diode (SPAD) working in an ultra-fast gating mode. A custom-made delay chip was integrated in the system to adjust the delay between the excitation laser pulse and the SPAD gate-ON window. This technique allowed to detect fluorescent photons of interest while rejecting most of the background photons, thus leading to a significantly improved signal to noise ratio (SNR). Experiments were carried out in turbid media mimicking tissue with an indocyanine green (ICG) inclusion (1 mM and 100 μM) to compare the time-gated technique and the conventional continuous detection technique. The gating technique increased twofold depth sensitivity, and tenfold SNR at large distances. The dual-modality imaging capacity of our system was also validated with a silicone-based tissue-mimicking phantom.

  3. Investigation of arginine A-specific cysteine proteinase gene expression profiling in clinical Porphyromonas gingivalis isolates against photokilling action of the photo-activated disinfection.

    Science.gov (United States)

    Pourhajibagher, Maryam; Ghorbanzadeh, Roghayeh; Bahador, Abbas

    2018-02-01

    Porphyromonas gingivalis is a significant root canal pathogen capable of causing endodontic infections, which during their treatment may receive sub-lethal doses of photo-activated disinfection (sPAD). As sPAD can influence microbial virulence, this study was designed to evaluate the effect of sPAD on gene expression level of arginine A-specific cysteine proteinase (rgpA), as one of the underlying virulence factors involved in the development of endodontic infection via P. gingivalis strains. To find out the sPAD against 16 clinical isolates of PAD-resistant P. gingivalis that were isolated in vivo, we used toluidine blue O (TBO), methylene blue (MB), and indocyanine green (ICG) as the photosensitizers, which were excited with specific wavelength of light in vitro. Quantitative real-time PCR (qRT-PCR) was then applied to monitor gene expression of rgpA in P. gingivalis isolates to characterize its virulence agent and understand the effect of sPAD on its pathogenicity. Maximal sPAD that could not decrease the count of P. gingivalis isolates were 6.25, 15.6, and 25 μg/mL at fluencies of 171.87, 15.6, and 93.75 J/cm 2 for TBO, ICG, and MB, respectively. ICG-sPAD could suppress the rgpA gene expression about 14-fold, while MB and TBO-mediated sPAD could cause the attenuation of rgpA expression about 4.9- and 11.6-fold, respectively. ICG-sPAD with the maximum ability to reduce rgpA gene expression compared with other photosensitizers can be an appropriate candidate for the treatment of endodontic infections.

  4. Dose-Volume Histogram Analysis of the Safety of Proton Beam Therapy for Unresectable Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Kawashima, Mitsuhiko; Kohno, Ryosuke; Nakachi, Kohei; Nishio, Teiji; Mitsunaga, Shuichi; Ikeda, Masafumi; Konishi, Masaru; Takahashi, Shinichiro; Gotohda, Naoto; Arahira, Satoko; Zenda, Sadamoto; Ogino, Takashi; Kinoshita, Taira

    2011-01-01

    Purpose: To evaluate the safety and efficacy of radiotherapy using proton beam (PRT) for unresectable hepatocellular carcinoma. Methods and Materials: Sixty consecutive patients who underwent PRT between May 1999 and July 2007 were analyzed. There were 42 males and 18 females, with a median age of 70 years (48-92 years). All but 1 patient had a single lesion with a median diameter of 45 mm (20-100 mm). Total PRT dose/fractionation was 76-cobalt Gray equivalent (CGE)/20 fractions in 46 patients, 65 CGE/26 fractions in 11 patients, and 60 CGE/10 fractions in 3 patients. The risk of developing proton-induced hepatic insufficiency (PHI) was estimated using dose-volume histograms and an indocyanine-green retention rate at 15 minutes (ICG R15). Results: None of the 20 patients with ICG R15 of less than 20% developed PHI, whereas 6 of 8 patients with ICG R15 values of 50% or higher developed PHI. Among 32 patients whose ICG R15 ranged from 20% to 49.9%, PHI was observed only in patients who had received 30 CGE (V30) to more than 25% of the noncancerous parts of the liver (n = 5) Local progression-free and overall survival rates at 3 years were 90% (95% confidence interval [CI], 80-99%) and 56% (95% CI, 43-69%), respectively. A gastrointestinal toxicity of Grade ≥2 was observed in 3 patients. Conclusions: ICG R15 and V30 are recommended as useful predictors for the risk of developing PHI, which should be incorporated into multidisciplinary treatment plans for patients with this disease.

  5. Imaging of solid tumor using near-infrared emitting purple bacteria

    International Nuclear Information System (INIS)

    Moon, Sung Min; Min, Jung Joon; Kim, Sun A; Choy, Hyon E.; Bom, Hee Seung

    2005-01-01

    Rhodobacter sphaeroides 2.4.1 is α-3 purple nonsulfur eubacterium with an extensive metabolism. Under anaerobic conditions, it is able to grow by photosynthesis, respiration and fermentation. When grown photosynthetically, it uses wavelengths of light in the near-infrared and contains a reaction center that is the peripheral light-harvesting (LH2) complex. These molecules absorb and emit near-infrared light. Using this near-infrared fluorescent bacterial we investigated its targeting capacity of solid tumor in small animals. R. sphaeroides 2.4.1 strains were cultured in sistrons minimal medium A (SIS) at 32 C. Xenograft tumor model has been established by subcutaneous injection of CT26 mouse colon cancer cell line. 1X10 8 Rhodobacter sphaeroides cells suspended in 100 ul of PBS were injected via tail vein with 1-cc insulin syringe into tumor bearing mouse. In vivo fluorescence imaging has been done after 20 min to 30 days of purple bacteria using indocyanine (ICG) emission filter (Em=810∼835 nm). Near-infrared imaging signal from Rhodobacter sphaeroides was initially detected at liver for 3 days but at the necrotic region of tumor mass thereafter. Total photon flux measured 5.5X10 8 (p/s/cm 2 /sr) at Day 1. Also it was increased to 7.8X10 8 (p/s/cm 2 /sr) at 12 day. One of important characteristic is that the signal appeared only at central necrosis area. It has been monitored for 36 day. We successfully imaged cancer with near-infrared fluorescence bacteria. Our result indicate that near-infrared fluorescence purple bacteria are able to be used to monitor bacterial trafficking in living tumor models

  6. Sentinel lymph node biopsy in endometrial cancer-Feasibility, safety and lymphatic complications.

    Science.gov (United States)

    Geppert, Barbara; Lönnerfors, Céline; Bollino, Michele; Persson, Jan

    2018-03-01

    To compare the rate of lymphatic complications in women with endometrial cancer undergoing sentinel lymph node biopsy versus a full pelvic and infrarenal paraaortic lymphadenectomy, and to examine the overall feasibility and safety of the former. A prospective study of 188 patients with endometrial cancer planned for robotic surgery. Indocyanine green was used to identify the sentinel lymph nodes. In low-risk patients the lymphadenectomy was restricted to removal of sentinel lymph nodes whereas in high-risk patients also a full lymphadenectomy was performed. The impact of the extent of the lymphadenectomy on the rate of complications was evaluated. The bilateral detection rate of sentinel lymph nodes was 96% after cervical tracer injection. No intraoperative complication was associated with the sentinel lymph node biopsy per se. Compared with hysterectomy alone, the additional average operative time for removal of sentinel lymph nodes was 33min whereas 91min were saved compared with a full pelvic and paraaortic lymphadenectomy. Sentinel lymph node biopsy alone resulted in a lower incidence of leg lymphedema than infrarenal paraaortic and pelvic lymphadenectomy (1.3% vs 18.1%, p=0.0003). The high feasibility, the absence of intraoperative complications and the low risk of lymphatic complications supports implementing detection of sentinel lymph nodes in low-risk endometrial cancer patients. Given that available preliminary data on sensitivity and false negative rates in high-risk patients are confirmed in further studies, we also believe that the reduction in lymphatic complications and operative time strongly motivates the sentinel lymph node concept in high-risk endometrial cancer. Copyright © 2017. Published by Elsevier Inc.

  7. In-vitro investigations of skin closure using diode laser and protein solder containing gold nano shells

    International Nuclear Information System (INIS)

    Nourbakhsh, M. S.; Etrati Khosroshahi, M.

    2011-01-01

    Laser tissue soldering is a new technique for repair of various tissues including the skin, liver, articular cartilage and nerves and is a promising alternative to suture. To overcome the problems of thermal damage to surrounding tissues and low laser penetration depth, some exogenous chromophores such as gold nano shells, a new class of nanoparticles consisting of a dielectric core surrounded by a thin metal shell, are used. The aims of this study were to use two different concentrations of gold nano shells as the exogenous material for skin tissue soldering and also to examine the effects of laser soldering parameters on the properties of the repaired skin. Material and Methods: Two mixtures of albumin solder and different concentrations of gold nano shells were prepared. A full thickness incision of 2*20 mm 2 was made on the surface and after placing 50 μ1 of the solder mixture on the incision, an 810 nm diode laser was used to irradiate it at different power densities. The changes of tensile strength, σt, due to temperature rise, number of scan (Ns), and scan velocity (Vs) were investigated. Results: The results showed that the tensile strength of the repaired skin increased with increasing irradiance for both gold nano shell concentrations. In addition, at constant laser irradiance (I), the tensile strength of the repaired incision increased with increasing Ns and decreasing Vs. In our case, this corresponded to σt = 1610 g/cm 2 at I ∼ 60 W cm-2, T ∼ 65 d egree C , Ns = 10 and Vs = 0.2 mms-1. Discussion and Conclusion: Gold nano shells can be used as an indocyanine green dye alterative for laser tissue soldering. Although by increasing the laser power density, the tensile strength of the repaired skin increases, an optimum power density must be considered due to the resulting increase in tissue temperature.

  8. Visualized Evaluation of Blood Flow to the Gastric Conduit and Complications in Esophageal Reconstruction.

    Science.gov (United States)

    Noma, Kazuhiro; Shirakawa, Yasuhiro; Kanaya, Nobuhiko; Okada, Tsuyoshi; Maeda, Naoaki; Ninomiya, Takayuki; Tanabe, Shunsuke; Sakurama, Kazufumi; Fujiwara, Toshiyoshi

    2018-03-01

    Evaluation of the blood supply to gastric conduits is critically important to avoid complications after esophagectomy. We began visual evaluation of blood flow using indocyanine green (ICG) fluorescent imaging in July 2015, to reduce reconstructive complications. In this study, we aimed to statistically verify the efficacy of blood flow evaluation using our simplified ICG method. A total of 285 consecutive patients who underwent esophagectomy and gastric conduit reconstruction were reviewed and divided into 2 groups: before and after introduction of ICG evaluation. The entire cohort and 68 patient pairs after propensity score matching (PS-M) were evaluated for clinical outcomes and the effect of visualized evaluation on reducing the risk of complication. The leakage rate in the ICG group was significantly lower than in the non-ICG group for each severity grade, both in the entire cohort (285 subjects) and after PS-M; the rates of other major complications, including recurrent laryngeal nerve palsy and pneumonia, were not different. The duration of postoperative ICU stay was approximately 1 day shorter in the ICG group than in the non-ICG group in the entire cohort, and approximately 2 days shorter after PS-M. Visualized evaluation of blood flow with ICG methods significantly reduced the rate of anastomotic complications of all Clavien-Dindo (CD) grades. Odds ratios for ICG evaluation decreased with CD grade (0.3419 for CD ≥ 1; 0.241 for CD ≥ 2; and 0.2153 for CD ≥ 3). Objective evaluation of blood supply to the reconstructed conduit using ICG fluorescent imaging reduces the risk and degree of anastomotic complication. Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Choroidal Round Hyporeflectivities in Geographic Atrophy.

    Directory of Open Access Journals (Sweden)

    Eleonora Corbelli

    Full Text Available In geographic atrophy (GA, choroidal vessels typically appear on structural optical coherence tomography (OCT as hyperreflective round areas with highly reflective borders. We observed that some GA eyes show choroidal round hyporeflectivities with highly reflective borders beneath the atrophy, and futher investigated the charcteristcs by comparing structural OCT, indocyanine green angiography (ICGA and OCT angiography (OCT-A.Round hyporeflectivities were individuated from a pool of patients with GA secondary to non-neovascular age-related macular degeneration consecutively presenting between October 2015 and March 2016 at the Medical Retina & Imaging Unit of the University Vita-Salute San Raffaele. Patients underwent a complete ophthalmologic examination including ICGA, structural OCT and OCT-A. The correspondence between choroidal round hyporeflectivities beneath GA on structural OCT and ICGA and OCT-A imaging were analyzed.Fifty eyes of 26 consecutive patients (17 females and 9 males; mean age 76.8±6.2 years with GA were included. Twenty-nine round hyporeflectivities have been found by OCT in choroidal layers in 21 eyes of 21 patients (42.0%; estimated prevalence of 57.7%. All 29 round hyporeflectivities showed constantly a hyperreflective border and a backscattering on structural OCT, and appeared as hypofluorescent in late phase ICGA and as dark foci with non detectable flow in the choroidal segmentation of OCT-A. Interestingly, the GA area was greater in eyes with compared to eyes without round hyporeflectivities (9.30±5.74 and 5.57±4.48mm2, respectively; p = 0.01.Our results suggest that most round hyporeflectivities beneath GA may represent non-perfused or hypo-perfused choroidal vessels with non-detectable flow.

  10. Choroidal Round Hyporeflectivities in Geographic Atrophy.

    Science.gov (United States)

    Corbelli, Eleonora; Sacconi, Riccardo; De Vitis, Luigi Antonio; Carnevali, Adriano; Rabiolo, Alessandro; Querques, Lea; Bandello, Francesco; Querques, Giuseppe

    2016-01-01

    In geographic atrophy (GA), choroidal vessels typically appear on structural optical coherence tomography (OCT) as hyperreflective round areas with highly reflective borders. We observed that some GA eyes show choroidal round hyporeflectivities with highly reflective borders beneath the atrophy, and futher investigated the charcteristcs by comparing structural OCT, indocyanine green angiography (ICGA) and OCT angiography (OCT-A). Round hyporeflectivities were individuated from a pool of patients with GA secondary to non-neovascular age-related macular degeneration consecutively presenting between October 2015 and March 2016 at the Medical Retina & Imaging Unit of the University Vita-Salute San Raffaele. Patients underwent a complete ophthalmologic examination including ICGA, structural OCT and OCT-A. The correspondence between choroidal round hyporeflectivities beneath GA on structural OCT and ICGA and OCT-A imaging were analyzed. Fifty eyes of 26 consecutive patients (17 females and 9 males; mean age 76.8±6.2 years) with GA were included. Twenty-nine round hyporeflectivities have been found by OCT in choroidal layers in 21 eyes of 21 patients (42.0%; estimated prevalence of 57.7%). All 29 round hyporeflectivities showed constantly a hyperreflective border and a backscattering on structural OCT, and appeared as hypofluorescent in late phase ICGA and as dark foci with non detectable flow in the choroidal segmentation of OCT-A. Interestingly, the GA area was greater in eyes with compared to eyes without round hyporeflectivities (9.30±5.74 and 5.57±4.48mm2, respectively; p = 0.01). Our results suggest that most round hyporeflectivities beneath GA may represent non-perfused or hypo-perfused choroidal vessels with non-detectable flow.

  11. Comparison of Near-Infrared Imaging Camera Systems for Intracranial Tumor Detection.

    Science.gov (United States)

    Cho, Steve S; Zeh, Ryan; Pierce, John T; Salinas, Ryan; Singhal, Sunil; Lee, John Y K

    2018-04-01

    Distinguishing neoplasm from normal brain parenchyma intraoperatively is critical for the neurosurgeon. 5-Aminolevulinic acid (5-ALA) has been shown to improve gross total resection and progression-free survival but has limited availability in the USA. Near-infrared (NIR) fluorescence has advantages over visible light fluorescence with greater tissue penetration and reduced background fluorescence. In order to prepare for the increasing number of NIR fluorophores that may be used in molecular imaging trials, we chose to compare a state-of-the-art, neurosurgical microscope (System 1) to one of the commercially available NIR visualization platforms (System 2). Serial dilutions of indocyanine green (ICG) were imaged with both systems in the same environment. Each system's sensitivity and dynamic range for NIR fluorescence were documented and analyzed. In addition, brain tumors from six patients were imaged with both systems and analyzed. In vitro, System 2 demonstrated greater ICG sensitivity and detection range (System 1 1.5-251 μg/l versus System 2 0.99-503 μg/l). Similarly, in vivo, System 2 demonstrated signal-to-background ratio (SBR) of 2.6 ± 0.63 before dura opening, 5.0 ± 1.7 after dura opening, and 6.1 ± 1.9 after tumor exposure. In contrast, System 1 could not easily detect ICG fluorescence prior to dura opening with SBR of 1.2 ± 0.15. After the dura was reflected, SBR increased to 1.4 ± 0.19 and upon exposure of the tumor SBR increased to 1.8 ± 0.26. Dedicated NIR imaging platforms can outperform conventional microscopes in intraoperative NIR detection. Future microscopes with improved NIR detection capabilities could enhance the use of NIR fluorescence to detect neoplasm and improve patient outcome.

  12. Three-dimensional reconstruction of the topographical cerebral surface anatomy for presurgical planning with free OsiriX Software.

    Science.gov (United States)

    Harput, Mehmet V; Gonzalez-Lopez, Pablo; Türe, Uğur

    2014-09-01

    During surgery for intrinsic brain lesions, it is important to distinguish the pathological gyrus from the surrounding normal sulci and gyri. This task is usually tedious because of the pia-arachnoid membranes with their arterial and venous complexes that obscure the underlying anatomy. Moreover, most tumors grow in the white matter without initially distorting the cortical anatomy, making their direct visualization more difficult. To create and evaluate a simple and free surgical planning tool to simulate the anatomy of the surgical field with and without vessels. We used free computer software (OsiriX Medical Imaging Software) that allowed us to create 3-dimensional reconstructions of the cerebral surface with and without cortical vessels. These reconstructions made use of magnetic resonance images from 51 patients with neocortical supratentorial lesions operated on over a period of 21 months (June 2011 to February 2013). The 3-dimensional (3-D) anatomic images were compared with the true surgical view to evaluate their accuracy. In all patients, the landmarks determined by 3-D reconstruction were cross-checked during surgery with high-resolution ultrasonography; in select cases, they were also checked with indocyanine green videoangiography. The reconstructed neurovascular structures were confirmed intraoperatively in all patients. We found this technique to be extremely useful in achieving pure lesionectomy, as it defines tumor's borders precisely. A 3-D reconstruction of the cortical surface can be easily created with free OsiriX software. This technique helps the surgeon perfect the mentally created 3-D picture of the tumor location to carry out cleaner, safer surgeries.

  13. Direct induction of hepatocyte-like cells from immortalized human bone marrow mesenchymal stem cells by overexpression of HNF4α

    International Nuclear Information System (INIS)

    Hu, Xiaojun; Xie, Peiyi; Li, Weiqiang; Li, Zhengran; Shan, Hong

    2016-01-01

    Hepatocytes from human bone marrow-derived mesenchymal stem cells (hBM-MSCs) are expected to be a useful source for cell transplantation. However, relatively low efficiency and repeatability of hepatic differentiation of human BM-MSCs remains an obstacle for clinical translation. Hepatocyte nuclear factor 4 alpha (HNF4α), a critical transcription factor, plays an essential role in the entire process of liver development. In this study, immortalized hBM-MSCs, UE7T-13 cells were transduced with a lentiviral vector containing HNF4α. The typical fibroblast-like morphology of the MSCs changed, and polygonal, epithelioid cells grew out after HNF4α transduction. In hepatocyte culture medium, HNF4α-transduced MSCs (E7-hHNF4α cells) strongly expressed the albumin (ALB), CYP2B6, alpha-1 antitrypsin (AAT), and FOXA2 mRNA and exhibited morphology markedly similar to that of mature hepatocytes. The E7-hHNF4α cells showed hepatic functions such as Indocyanine green (ICG) uptake and release, glycogen storage, urea production and ALB secretion. Approximately 28% of E7-hHNF4α cells expressed both ALB and AAT. Furthermore, these E7-hHNF4α cells via superior mesenteric vein (SMV) injection expressed human ALB in mouse chronic injured liver. In conclusion, this study represents a novel strategy by directly inducing hepatocyte-like cells from MSCs. - Highlights: • We overexpressed HNF4α in immortalized BM-MSCs by lentiviral transduction. • HNF4α-transduced MSCs transdifferentiated into hepatocytes with mature hepatic metabolic functions. • Our study represents a novel strategy by direct induction of hepatocyte-like cells from MSCs.

  14. A Technique to Define Extrahepatic Biliary Anatomy Using Robotic Near-Infrared Fluorescent Cholangiography.

    Science.gov (United States)

    Maker, Ajay V; Kunda, Nicholas

    2017-11-01

    Bile duct injury is a rare but serious complication of minimally invasive cholecystectomy. Traditionally, intraoperative cholangiogram has been used in difficult cases to help delineate anatomical structures, however, new imaging modalities are currently available to aid in the identification of extrahepatic biliary anatomy, including near-infrared fluorescent cholangiography (NIFC) using indocyanine green (ICG).1-5 The objective of the study was to evaluate if this technique may aid in safe dissection to obtain the critical view. Thirty-five consecutive multiport robotic cholecystectomies using NIFC with ICG were performed using the da Vinci Firefly Fluorescence Imaging System. All patients received 2.5 mg ICG intravenously at the time of intubation, followed by patient positioning, draping, and establishment of pneumoperitoneum. No structures were divided until the critical view of safety was achieved. Real-time toggling between NIFC and bright-light illumination was utilized throughout the case to define the extrahepatic biliary anatomy. ICG was successfully administered to all patients without complication, and in all cases the extrahepatic biliary anatomy was able to be identified in real-time 3D. All procedures were completed without biliary injury, conversion to an open procedure, or need for traditional cholangiography to obtain the critical view. Specific examples of cases where x-ray cholangiography or conversion to open was avoided and NIFC aided in safe dissection leading to the critical view are demonstrated, including (1) evaluation for aberrant biliary anatomy, (2) confirmation of non-biliary structures, and (3) use in cases where the infundibulum is fused to the common bile duct. NIFC using ICG is demonstrated as a useful technique to rapidly identify and aid in the visualization of extrahepatic biliary anatomy. Techniques that selectively utilize this technology specifically in difficult cases where the anatomy is unclear are demonstrated in order

  15. Prediction of Liver Function by Using Magnetic Resonance-based Portal Venous Perfusion Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cao Yue, E-mail: yuecao@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Wang Hesheng [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Johnson, Timothy D. [Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Pan, Charlie [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Hussain, Hero [Department of Radiology, University of Michigan, Ann Arbor, Michigan (United States); Balter, James M.; Normolle, Daniel; Ben-Josef, Edgar; Ten Haken, Randall K.; Lawrence, Theodore S.; Feng, Mary [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2013-01-01

    Purpose: To evaluate whether liver function can be assessed globally and spatially by using volumetric dynamic contrast-enhanced magnetic resonance imaging MRI (DCE-MRI) to potentially aid in adaptive treatment planning. Methods and Materials: Seventeen patients with intrahepatic cancer undergoing focal radiation therapy (RT) were enrolled in institution review board-approved prospective studies to obtain DCE-MRI (to measure regional perfusion) and indocyanine green (ICG) clearance rates (to measure overall liver function) prior to, during, and at 1 and 2 months after treatment. The volumetric distribution of portal venous perfusion in the whole liver was estimated for each scan. We assessed the correlation between mean portal venous perfusion in the nontumor volume of the liver and overall liver function measured by ICG before, during, and after RT. The dose response for regional portal venous perfusion to RT was determined using a linear mixed effects model. Results: There was a significant correlation between the ICG clearance rate and mean portal venous perfusion in the functioning liver parenchyma, suggesting that portal venous perfusion could be used as a surrogate for function. Reduction in regional venous perfusion 1 month after RT was predicted by the locally accumulated biologically corrected dose at the end of RT (P<.0007). Regional portal venous perfusion measured during RT was a significant predictor for regional venous perfusion assessed 1 month after RT (P<.00001). Global hypovenous perfusion pre-RT was observed in 4 patients (3 patients with hepatocellular carcinoma and cirrhosis), 3 of whom had recovered from hypoperfusion, except in the highest dose regions, post-RT. In addition, 3 patients who had normal perfusion pre-RT had marked hypervenous perfusion or reperfusion in low-dose regions post-RT. Conclusions: This study suggests that MR-based volumetric hepatic perfusion imaging may be a biomarker for spatial distribution of liver function, which

  16. Recent development of fluorescent imaging for specific detection of tumors

    International Nuclear Information System (INIS)

    Nakata, Eiji; Morii, Takashi; Uto, Yoshihiro; Hori, Hitoshi

    2011-01-01

    Increasing recent studies on fluorescent imaging for specific detection of tumors are described here on strategies of molecular targeting, metabolic specificity and hypoxic circumstance. There is described an instance of a conjugate of antibody and pH-activable fluorescent ligand, which specifically binds to the tumor cells, is internalized in the cellular lysozomes where their pH is low, and then is activated to become fluorescent only in viable tumor cells. For the case of metabolic specificity, excessive loading of the precursor (5-aminolevulinic acid) of protoporphyrin IX (ppIX), due to their low activity to convert ppIX to heme B, results in making tumors observable in red as ppIX emits fluorescence (red, 585 nm) when excited by blue ray of 410 nm. Similarly, imaging with indocyanine green which is accumulated in hepatoma cells is reported in success in detection of small lesion and metastasis when the dye is administered during operation. Reductive reactions exceed in tumor hypoxic conditions, of which feature is usable for imaging. Conjugates of nitroimidazole and fluorescent dye are reported to successfully image tumors by nitro reduction. Authors' UTX-12 is a non-fluorescent nitroaromatic derivative of pH-sensitive fluorescent dye seminaphtharhodafluor (SNARF), and is designed for the nitro group, the hypoxia-responding sensor, to be reduced in tumor hypoxic conditions and then for the aromatic moiety to be cleaved to release free SNARF. Use of hypoxia-inducible factor-1 (HIF-1) for imaging has been also reported in many. As above, studies on fluorescent imaging for specific detection of tumors are mostly at fundamental step but its future is conceivably promising along with advances in other technology like fluorescent endoscopy and multimodal imaging. (author)

  17. Sentinel lymph node mapping in minimally invasive surgery: Role of imaging with color-segmented fluorescence (CSF).

    Science.gov (United States)

    Lopez Labrousse, Maite I; Frumovitz, Michael; Guadalupe Patrono, M; Ramirez, Pedro T

    2017-09-01

    Sentinel lymph node mapping, alone or in combination with pelvic lymphadenectomy, is considered a standard approach in staging of patients with cervical or endometrial cancer [1-3]. The goal of this video is to demonstrate the use of indocyanine green (ICG) and color-segmented fluorescence when performing lymphatic mapping in patients with gynecologic malignancies. Injection of ICG is performed in two cervical sites using 1mL (0.5mL superficial and deep, respectively) at the 3 and 9 o'clock position. Sentinel lymph nodes are identified intraoperatively using the Pinpoint near-infrared imaging system (Novadaq, Ontario, CA). Color-segmented fluorescence is used to image different levels of ICG uptake demonstrating higher levels of perfusion. A color key on the side of the monitor shows the colors that coordinate with different levels of ICG uptake. Color-segmented fluorescence may help surgeons identify true sentinel nodes from fatty tissue that, although absorbing fluorescent dye, does not contain true nodal tissue. It is not intended to differentiate the primary sentinel node from secondary sentinel nodes. The key ranges from low levels of ICG uptake (gray) to the highest rate of ICG uptake (red). Bilateral sentinel lymph nodes are identified along the external iliac vessels using both standard and color-segmented fluorescence. No evidence of disease was noted after ultra-staging was performed in each of the sentinel nodes. Use of ICG in sentinel lymph node mapping allows for high bilateral detection rates. Color-segmented fluorescence may increase accuracy of sentinel lymph node identification over standard fluorescent imaging. The following are the supplementary data related to this article. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Fluorescence optical imaging and 3T-MRI for detection of synovitis in patients with rheumatoid arthritis in comparison to a composite standard of reference.

    Science.gov (United States)

    Thuermel, Klaus; Neumann, Jan; Jungmann, Pia M; Schäffeler, Christoph; Waldt, Simone; Heinze, Alexander; Beckmann, Alexander; Hauser, Christine; Hasenau, Anna-Lena; Wildgruber, Moritz; Clotten, Sigrun; Sievert, Matti; Haller, Bernhard; Woertler, Klaus; Harasser, Norbert; Rummeny, Ernst J; Meier, Reinhard

    2017-05-01

    To address whether Indocyanine Green (ICG) enhanced fluorescence optical imaging (FOI) is more sensitive than magnetic resonance imaging (MRI) in the detection of synovitis of the wrist and finger joints in rheumatoid arthritis and to analyze the performance of FOI depending on the grade of synovitis. Twenty patients with highly active rheumatoid arthritis (mean DAS28-ESR 5.25±1.0) and thirteen healthy volunteers underwent clinical examination, FOI and contrast-enhanced 3T-MRI. Joints were rated by three independent readers semiquantitatively (grade 0-3: no, low, moderate and high grade synovitis) and compared to a semiquantitative composite standard of reference (cSOR, grade 0-3) that incorporated clinical parameters, FOI and MRI results. 2.868 evaluations in 956 joints were performed. FOI had an overall sensitivity of 57.3% and a specificity of 92.1%, whereas MRI had a sensitivity of 89.2% and a specificity of 92.6%. The sensitivity of FOI increased with the degree of synovitis to 65.0% for moderate and severe synovitis (specificity 88.1%) and 76,3% for severe synovitis (specificity 80.5%). The performance of FOI decreased with the degree of synovitis with false negative results predominantly for mild (156/343, 45.5%) and moderate (160/343, 46.6%) synovitis and false positive FOI evaluations predominantly based on weak (grade 1) signals (133/163, 81,6%). FOI has a lower sensitivity than 3T-MRI in the detection of synovitis of the hand and finger joints. The diagnostic performance of FOI decreases with the degree of synovitis and with the strength of FOI signals. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Evaluation of focal choroidal excavation in the macula using swept-source optical coherence tomography.

    Science.gov (United States)

    Lim, F P M; Loh, B K; Cheung, C M G; Lim, L S; Chan, C M; Wong, D W K

    2014-09-01

    To evaluate imaging findings of patients with focal choroidal excavation (FCE) in the macula using swept-source optical coherence tomography (SS-OCT) and correlate it clinically. Prospective observational case series. Eleven consecutive patients (12 eyes) with FCE were described. Data on demographics and clinical presentation were collected and imaging findings (including color photography, fundus autofluorescence imaging, fluorescein angiography, indocyanine green angiography, spectral-domain optical coherence tomography, and SS-OCT) were analyzed. The primary diagnosis was epiretinal membrane (two eyes), choroidal neovascularization (one eye), polypoidal choroidal vasculopathy (three eyes), central serous chorioretinopathy (one eye), and dry age-related macular degeneration (two eyes). Eleven out of 12 of the lesions were conforming. One presented with a non-conforming lesion that progressed to a conforming lesion. One eye had multiFCE and two had two overlapping choroidal excavations. Using the SS-OCT, we found the choroid to be thinned out at the area of FCE but sclera remained normal. The choroidal tissue beneath the FCE was abnormal, with high internal reflectivity and poor visualization of choroidal vessels. There was loss of contour of the outer choroidal boundary that appeared to be pulled inward by this abnormal choroidal tissue. A suprachoroidal space was noted beneath this choroidal tissue and the choroidal-scleral interface was smooth. Repeat SS-OCT 6 months after presentation showed the area of excavation to be stable in size. FCE can be associated with epiretinal membrane, central serous chorioretinopathy, and age-related macular degeneration. The choroid was thinned out in the area of FCE.

  20. Surgical anatomy and preservation of the middle meningeal artery during bypass surgery for moyamoya disease.

    Science.gov (United States)

    Hori, Satoshi; Kashiwazaki, Daina; Akioka, Naoki; Hayashi, Tomohide; Hori, Emiko; Umemura, Kimiko; Horie, Yukio; Kuroda, Satoshi

    2015-01-01

    The middle meningeal artery (MMA) is known to function as one of the important collateral routes in moyamoya disease. However, the anterior branch frequently courses within the lesser wing of the sphenoid bone and can easily be damaged during craniotomy for bypass surgery. This prospective study aimed to study the surgical anatomy of the MMA and to establish the technique to preserve it during bypass surgery for moyamoya disease. Twenty-two patients with moyamoya disease underwent STA-MCA anastomosis combined with indirect bypass on 27 sides. The anatomical relationship between the anterior branch of the MMA and lesser wing was classified into three types: the bridge, monorail, and tunnel types. During surgery, the lesser wing was carefully resected with a rongeur or high-speed diamond drill to preserve the anterior branch of the MMA. The anterior branch of the MMA was classified into the bridge type in 5 sides (18.5 %), monorail type in 10 sides (37.0 %), and tunnel type in 12 sides (44.5 %). Patient age was closely related to the anatomical findings (χ (2) test, p = 0.0168). Careful resection of the lesser wing with a rongeur could preserve bridge- and monorail-type MMAs (100 and 71.4 %, respectively). However, drilling out of the lesser wing under a surgical microscope was essential to preserve the tunnel-type MMA. Intraoperative indocyanine green videoangiography was useful to confirm patency during surgery. It is essential to understand the surgical anatomy of the MMA around the pterion in order to preserve its anterior branch during bypass surgery for moyamoya disease.

  1. Study of krypton laser-induced choroidal neovascularization in a Guinea pig model of high anisometropia.

    Science.gov (United States)

    Wang, Jianghui; Jiang, Wei; Kang, Zefeng; Liang, Lina; Liu, Xiaoman; Tian, Nannan; Zhang, Qing

    2012-06-01

    To investigate the association between high anisometropia and the area of choroidal neovascularization (CNV) induced by krypton laser in guinea pigs and better understand the pathogenesis and prevention of myopic CNV. Nine 3-week old male guinea pigs with anisometropia >6.00D were randomly assigned to three groups according to examination date after laser photocoagulation (7d, 14d and 28d). All animals underwent refraction. The eye with higher myopia was used as the experimental eye, and the other as the control eye. All eyes received repeated multi-wavelength krypton laser photocoagulation treatments (wavelength: 532nm; laser power: 400mW; spot diameter: 50μm; exposure time: 0.1s). Fundus photography and indocyanine green angiography (ICGA) were performed. Afterwards, the animals were sacrificed immediately, and the eyes were enucleated and processed for histopathologic examination and flat mounts. CNV appeared at 7d after laser treatment. The area of CNV peaked at 14d, and decrease in area and the presence of scarring was noted at 28 d. CNV was present in 66.7% of eyes by ICGA at 14 d. CNV could be observed under light microscopy at all three time points. At 14d, flat mount showed the neovascular plexus around the lesion. Semi-quantitative analysis revealed that the area of CNV in treated eyes was greater than that of control eyes. Since the mechanism of CNV in this study resembles that of CNV in pathological myopia, this model can be used to investigate the etiology, pathogenesis and treatment of CNV in pathological myopia.

  2. Fluorescent Angiography Used to Evaluate the Perfusion Status of Anastomosis in Laparoscopic Anterior Resection.

    Science.gov (United States)

    Koh, Frederick H; Tan, Ker-Kan

    2016-12-01

    Anastomotic leakage after gastrointestinal surgery is associated with significant morbidity and mortality.1 Insufficient vascular supply is one cause.2 Recent reports of using intraoperative indocyanine green (ICG) fluorescent angiography to evaluate whether perfusion of the anastomosis is adequate has yielded positive outcomes.3 - 6 The authors describe their use of ICG-enhanced fluorescence angiography in a laparoscopic anterior resection. The patient was an 80-year-old with an upper rectal adenocarcinoma and significant cardiovascular risk factors. Fluorescence angiography with 0.4 mg/kg of ICG was administered intravenously just before the colorectal anastomosis was fashioned. A near-infrared (NIR) laparoscopic camera (KARLSTORZ, GmbH & Co. KG, Tuttlingen, Germany) was used to inspect the anastomosis. For this video, 0.4 mg/kg of ICG also was injected after ligation of the inferior mesenteric artery to demonstrate the appearance of a poorly perfused sigmoid bowel. Just before the staple was fired to fashion the colorectal anastomosis, an intravenous bolus of ICG was administered. Within seconds, vessels on both ends of the anastomosis turned fluorescent blue, indicating adequacy of perfusion. The use of ICG did not significantly lengthen the operative time (285 min) because its effect appeared within seconds after its administration. The patient recovered well and was discharged on postoperative day 5. Another four patients who also underwent intraoperative fluorescent angiography for left-sided colorectal lesions did not experience anastomotic leakage. The study showed that ICG fluorescent angiography is a simple and quick intraoperative tool for evaluating the perfusion of the anastomosis. The authors' experience with ICG fluorescent angiography has shown promising results, with a 0 % anastomotic leak rate.

  3. Transected sciatic nerve repair by diode laser protein soldering.

    Science.gov (United States)

    Fekrazad, Reza; Mortezai, Omid; Pedram, MirSepehr; Kalhori, Katayoun Am; Joharchi, Khojasteh; Mansoori, Korosh; Ebrahimi, Roja; Mashhadiabbas, Fatemeh

    2017-08-01

    Despite advances in microsurgical techniques, repair of peripheral nerve injuries (PNI) is still a major challenge in regenerative medicine. The standard treatment for PNI includes suturing and anasthomosis of the transected nerve. The objective of this study was to compare neurorraphy (nerve repair) using standard suturingto diode laser protein soldering on the functional recovery of transected sciatic nerves. Thirty adult male Fischer-344 Wistar rats were randomly assigned to 3 groups: 1. The control group, no repair, 2. the standard of care suture group, and 3. The laser/protein solder group. For all three groups, the sciatic nerve was transected and the repair was done immediately. For the suture repair group, 10.0 prolene suture was used and for the laser/protein solder group a diode laser (500mW output power) in combination with bovine serum albumen and indocyanine green dye was used. Behavioral assessment by sciatic functional index was done on all rats biweekly. At 12weeks post-surgery, EMG recordings were done on all the rats and the rats were euthanized for histological evaluation of the sciatic nerves. The one-way ANOVA test was used for statistical analysis. The average time required to perform the surgery was significantly shorter for the laser-assisted nerve repair group compared to the suture group. The EMG evaluation revealed no difference between the two groups. Based on the sciatic function index the laser group was significantly better than the suture group after 12weeks (pneurorraphy using standard suturing methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. The characterization of an economic and portable LED-based photoacoustic imaging system to facilitate molecular imaging

    Directory of Open Access Journals (Sweden)

    Ali Hariri

    2018-03-01

    Full Text Available Photoacoustic imaging (PAI is a non-invasive, high-resolution hybrid imaging modality that combines optical excitation and ultrasound detection. PAI can image endogenous chromophores (melanin, hemoglobin, etc. and exogenous contrast agents in different medical applications. However, most current equipment uses sophisticated and complicated OPO lasers with tuning and stability features inconsistent with broad clinical deployment. As the number of applications of PAI in medicine increases, there is an urgent need to make the imaging equipment more compact, portable, and affordable. Here, portable light emitting diode – based photoacoustic imaging (PLED-PAI was introduced and characterized in terms of system specifications, light source characterizations, photoacoustic spatial/temporal resolution, and penetration. The system uses two LED arrays attached to the sides of a conventional ultrasound transducer. The LED pulse repetition rate is tunable between 1 K Hz, 2 K Hz, 3 K Hz, and 4 K Hz. The axial resolution was 0.268 mm, and the lateral resolution was between 0.55 and 0.59 mm. The system could detect optical absorber (pencil lead at a depth of 3.2 cm and the detection limits of indocyanine green (ICG and methylene blue (MB were 9 μM and 0.78 mM. In vivo imaging of labeled human mesenchymal stem cells was achieved to confirm compatibility with small animal imaging. The characterization we report here may have value to other groups evaluating commercially available photoacoustic imaging equipment. Keywords: Portable photoacoustic imaging, LED, Optoacoustic imaging, Molecular imaging

  5. Rapid multi-wavelength optical assessment of circulating blood volume without a priori data

    Science.gov (United States)

    Loginova, Ekaterina V.; Zhidkova, Tatyana V.; Proskurnin, Mikhail A.; Zharov, Vladimir P.

    2016-03-01

    The measurement of circulating blood volume (CBV) is crucial in various medical conditions including surgery, iatrogenic problems, rapid fluid administration, transfusion of red blood cells, or trauma with extensive blood loss including battlefield injuries and other emergencies. Currently, available commercial techniques are invasive and time-consuming for trauma situations. Recently, we have proposed high-speed multi-wavelength photoacoustic/photothermal (PA/PT) flow cytometry for in vivo CBV assessment with multiple dyes as PA contrast agents (labels). As the first step, we have characterized the capability of this technique to monitor the clearance of three dyes (indocyanine green, methylene blue, and trypan blue) in an animal model. However, there are strong demands on improvements in PA/PT flow cytometry. As additional verification of our proof-of-concept of this technique, we performed optical photometric CBV measurements in vitro. Three label dyes—methylene blue, crystal violet and, partially, brilliant green—were selected for simultaneous photometric determination of the components of their two-dye mixtures in the circulating blood in vitro without any extra data (like hemoglobin absorption) known a priori. The tests of single dyes and their mixtures in a flow system simulating a blood transfusion system showed a negligible difference between the sensitivities of the determination of these dyes under batch and flow conditions. For individual dyes, the limits of detection of 3×10-6 M‒3×10-6 M in blood were achieved, which provided their continuous determination at a level of 10-5 M for the CBV assessment without a priori data on the matrix. The CBV assessment with errors no higher than 4% were obtained, and the possibility to apply the developed procedure for optical photometric (flow cytometry) with laser sources was shown.

  6. The Expansion of RPE Atrophy after the Inverted ILM Flap Technique for a Chronic Large Macular Hole

    Directory of Open Access Journals (Sweden)

    Hisanori Imai

    2014-03-01

    Full Text Available Purpose: To report a case of the expansion of submacular retinal pigment epithelium (RPE atrophy after using the inverted internal limiting membrane (ILM flap technique for a persisting, large, stage IV macular hole (MH. Case Report: A 79-year-old woman presented with a chronic large MH that remained open despite pars plana vitrectomy (PPV. The surgery was performed twice for the MH closure 14 years earlier. ILM peeling was not performed during the previous surgeries. The best-corrected visual acuity (BCVA with the Landolt ring chart was 0.08 at her visit. The minimum MH diameter was 1,240 μm. Inverted ILM flap technique with 20% SF6 gas tamponade was performed for the MH closure. For the inverted ILM flap technique, 25-gauge PPV and ILM staining with indocyanine green were used. The ILM was peeled off for 2 disc diameters around the MH, but the ILM was not removed completely. The ILM was then inverted and covered the MH. Results: One month after surgery, the MH was closed, accompanied by glial cell proliferation spreading from the inverted ILM flap (as reported before. On the other hand, the area of the submacular RPE atrophy, which was already observed 1 week after surgery, gradually increased in size. BCVA improved to 0.3 six months after the surgery. Conclusions: The inverted ILM flap technique may be promising even for persisting large MH which were not closed in previous surgeries, but long-term observation is needed because the detailed behavior of the inverted ILM and the Müller cells after surgery is not yet known.

  7. Characterizing the Utility and Limitations of Repurposing an Open-Field Optical Imaging Device for Fluorescence-Guided Surgery in Head and Neck Cancer Patients.

    Science.gov (United States)

    Moore, Lindsay S; Rosenthal, Eben L; Chung, Thomas K; de Boer, Esther; Patel, Neel; Prince, Andrew C; Korb, Melissa L; Walsh, Erika M; Young, E Scott; Stevens, Todd M; Withrow, Kirk P; Morlandt, Anthony B; Richman, Joshua S; Carroll, William R; Zinn, Kurt R; Warram, Jason M

    2017-02-01

    The purpose of this study was to assess the potential of U.S. Food and Drug Administration-cleared devices designed for indocyanine green-based perfusion imaging to identify cancer-specific bioconjugates with overlapping excitation and emission wavelengths. Recent clinical trials have demonstrated potential for fluorescence-guided surgery, but the time and cost of the approval process may impede clinical translation. To expedite this translation, we explored the feasibility of repurposing existing optical imaging devices for fluorescence-guided surgery. Consenting patients (n = 15) scheduled for curative resection were enrolled in a clinical trial evaluating the safety and specificity of cetuximab-IRDye800 (NCT01987375). Open-field fluorescence imaging was performed preoperatively and during the surgical resection. Fluorescence intensity was quantified using integrated instrument software, and the tumor-to-background ratio characterized fluorescence contrast. In the preoperative clinic, the open-field device demonstrated potential to guide preoperative mapping of tumor borders, optimize the day of surgery, and identify occult lesions. Intraoperatively, the device demonstrated robust potential to guide surgical resections, as all peak tumor-to-background ratios were greater than 2 (range, 2.2-14.1). Postresection wound bed fluorescence was significantly less than preresection tumor fluorescence (P open-field imaging device was successfully repurposed to distinguish cancer from normal tissue in the preoperative clinic and throughout surgical resection. This study illuminated the potential for existing open-field optical imaging devices with overlapping excitation and emission spectra to be used for fluorescence-guided surgery. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  8. In-vitro Investigations of Skin Closure using Diode Laser and Protein Solder Containing Gold Nanoshells

    Directory of Open Access Journals (Sweden)

    Mohammad Sadegh Nourbakhsh

    2010-12-01

    Full Text Available Introduction: Laser tissue soldering is a new technique for repair of various tissues including the skin, liver, articular cartilage and nerves and is a promising alternative to suture. To overcome the problems of thermal damage to surrounding tissues and low laser penetration depth, some exogenous chromophores such as gold nanoshells, a new class of nanoparticles consisting of a dielectric core surrounded by a thin metal shell, are used. The aims of this study were to use two different concentrations of gold nanoshells as the exogenous material for skin tissue soldering and also to examine the effects of laser soldering parameters on the properties of the repaired skin. Material and Methods: Two mixtures of albumin solder and different concentrations of gold nanoshells were prepared. A full thickness incision of 2×20 mm2 was made on the surface and after placing 50 μl of the solder mixture on the incision, an 810 nm diode laser was used to irradiate it at different power densities. The changes of tensile strength, σt, due to temperature rise, number of scan (Ns, and scan velocity (Vs were investigated. Results: The results showed that the tensile strength of the repaired skin increased with increasing irradiance for both gold nanoshell concentrations. In addition, at constant laser irradiance (I, the tensile strength of the repaired incision increased with increasing Ns and decreasing Vs. In our case, this corresponded to st = 1610 g/cm2 at I ~ 60 Wcm-2, T ~ 65ºC, Ns = 10 and Vs = 0.2 mms-1. Discussion and Conclusion: Gold nanoshells can be used as an indocyanine green dye (ICG alterative for laser tissue soldering.  Although by increasing the laser power density, the tensile strength of the repaired skin increases, an optimum power density must be considered due to the resulting increase in tissue temperature.

  9. Concomitant radio- and fluorescence-guided sentinel lymph node biopsy in squamous cell carcinoma of the oral cavity using ICG-{sup 99m}Tc-nanocolloid

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Nynke S. van den; Leeuwen, Fijs W.B. van [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Leiden University Medical Center, Department of Radiology, Interventional Molecular Imaging Section, Albinusdreef 2 (C2-S zone), P.O. Box 9600, Leiden (Netherlands); Brouwer, Oscar R.; Valdes Olmos, Renato A. [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Klop, W.M.C.; Karakullukcu, Baris; Zuur, Charlotte L.; Tan, I.B.; Balm, Alfons J.M.; Brekel, Michiel W.M. van den [Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Department of Head and Neck Surgery and Oncology, Amsterdam (Netherlands)

    2012-07-15

    For oral cavity malignancies, sentinel lymph node (SLN) mapping is performed by injecting a radiocolloid around the primary tumour followed by lymphoscintigraphy. Surgically, SLNs can then be localized using a handheld gamma ray detection probe. The aim of this study was to evaluate the added value of intraoperative fluorescence imaging to the conventional radioguided procedure. For this we used indocyanine green (ICG)-{sup 99m}Tc-nanocolloid, a hybrid tracer that is both radioactive and fluorescent. Fourteen patients with oral cavity squamous cell carcinoma were peritumourally injected with ICG-{sup 99m}Tc-nanocolloid. SLNs were preoperatively identified with lymphoscintigraphy followed by single photon emission computed tomography (SPECT)/CT for anatomical localization. During surgery, SLNs were detected with a handheld gamma ray detection probe and a handheld near-infrared fluorescence camera. Pre-incision and post-excision imaging with a portable gamma camera was performed to confirm complete removal of all SLNs. SLNs were preoperatively identified using the radioactive signature of ICG-{sup 99m}Tc-nanocolloid. Intraoperatively, 43 SLNs could be localized and excised with combined radio- and fluorescence guidance. Additionally, in four patients, an SLN located close to the primary injection site (in three patients this SLN was located in level I) could only be intraoperatively localized using fluorescence imaging. Pathological analysis of the SLNs revealed a metastasis in one patient. Combined preoperative SLN identification and intraoperative radio- and fluorescence guidance during SLN biopsies for oral cavity cancer proved feasible using ICG-{sup 99m}Tc-nanocolloid. The addition of fluorescence imaging was shown to be of particular value when SLNs were located in close proximity to the primary tumour. (orig.)

  10. The utility of quantitative 99mTc-GSA liver scintigraphy in the evaluation of hepatic functional reserve

    International Nuclear Information System (INIS)

    Shuke, Noriyuki; Aburano, Tamio; Nakajima, Kenichi

    1992-01-01

    Using data from 17 patients with liver cirrhosis and 3 patients with fatty liver, we have compared the utility of 3 hepatic imaging agents in the evalution of hepatic functional reserve. Evaluated here were 99m Tc-galactosyl human serum albumin (GSA) which is a new ligand for hepatic binding protein, 99m Tc-N-pyridoxyl-5-methyl tryptophan (PMT) of a hepatobiliary agent, and 99m Tc-Sn colloid. In each patient, we performed these 3 imaging studies within a week and also examined hepatic function tests (indocyanine green test, hepaplastin test, choline-esterase, etc). In each imaging study, serial images and dynamic data were obtained after the injection of 99m Tc-GSA (185 MBq/3 mg), 99m Tc-PMT (185 MBq), or 99m Tc-Sn colloid (185 MBq). Using the dynamic data obtained, we analyzed the liver kinetics of the 3 agents based on 1 compartment model with 3 parameters (hepatic clearance, hepatic excretion rate, non-specific volume of distribution). From fitting the liver and heart data to this model, three unknown parameters were determined. Patlak plot was also applied in order to estimate liver uptake rate. Both curve fitting and Patlak plot could determine appropriate parameters in every study. In 99m Tc-GSA, a nonlinear 3 compartment model was also applied in order to estimate hepatic blood flow, liver receptor density, and affinity of receptor-GSA binding separately. Using the parameters obtained, we analyzed the correlations between the parameters and the results of hepatic function tests. In all of the parameters, those obtained from 99m Tc-GSA imaging showed the most significant statistical correlation with the results of hepatic function tests. From the present results, 99m Tc-GSA imaging was concluded to be the best for evaluation of hepatic functional reserve. (author)

  11. The characterization of an economic and portable LED-based photoacoustic imaging system to facilitate molecular imaging.

    Science.gov (United States)

    Hariri, Ali; Lemaster, Jeanne; Wang, Junxin; Jeevarathinam, AnanthaKrishnan S; Chao, Daniel L; Jokerst, Jesse V

    2018-03-01

    Photoacoustic imaging (PAI) is a non-invasive, high-resolution hybrid imaging modality that combines optical excitation and ultrasound detection. PAI can image endogenous chromophores (melanin, hemoglobin, etc.) and exogenous contrast agents in different medical applications. However, most current equipment uses sophisticated and complicated OPO lasers with tuning and stability features inconsistent with broad clinical deployment. As the number of applications of PAI in medicine increases, there is an urgent need to make the imaging equipment more compact, portable, and affordable. Here, portable light emitting diode - based photoacoustic imaging (PLED-PAI) was introduced and characterized in terms of system specifications, light source characterizations, photoacoustic spatial/temporal resolution, and penetration. The system uses two LED arrays attached to the sides of a conventional ultrasound transducer. The LED pulse repetition rate is tunable between 1 K Hz, 2 K Hz, 3 K Hz, and 4 K Hz. The axial resolution was 0.268 mm, and the lateral resolution was between 0.55 and 0.59 mm. The system could detect optical absorber (pencil lead) at a depth of 3.2 cm and the detection limits of indocyanine green (ICG) and methylene blue (MB) were 9 μM and 0.78 mM. In vivo imaging of labeled human mesenchymal stem cells was achieved to confirm compatibility with small animal imaging. The characterization we report here may have value to other groups evaluating commercially available photoacoustic imaging equipment.

  12. Evaluation of focal choroidal excavation in the macula using swept-source optical coherence tomography

    Science.gov (United States)

    Lim, F P M; Loh, B K; Cheung, C M G; Lim, L S; Chan, C M; Wong, D W K

    2014-01-01

    Purpose To evaluate imaging findings of patients with focal choroidal excavation (FCE) in the macula using swept-source optical coherence tomography (SS-OCT) and correlate it clinically. Methods Prospective observational case series. Eleven consecutive patients (12 eyes) with FCE were described. Data on demographics and clinical presentation were collected and imaging findings (including color photography, fundus autofluorescence imaging, fluorescein angiography, indocyanine green angiography, spectral-domain optical coherence tomography, and SS-OCT) were analyzed. Results The primary diagnosis was epiretinal membrane (two eyes), choroidal neovascularization (one eye), polypoidal choroidal vasculopathy (three eyes), central serous chorioretinopathy (one eye), and dry age-related macular degeneration (two eyes). Eleven out of 12 of the lesions were conforming. One presented with a non-conforming lesion that progressed to a conforming lesion. One eye had multiFCE and two had two overlapping choroidal excavations. Using the SS-OCT, we found the choroid to be thinned out at the area of FCE but sclera remained normal. The choroidal tissue beneath the FCE was abnormal, with high internal reflectivity and poor visualization of choroidal vessels. There was loss of contour of the outer choroidal boundary that appeared to be pulled inward by this abnormal choroidal tissue. A suprachoroidal space was noted beneath this choroidal tissue and the choroidal–scleral interface was smooth. Repeat SS-OCT 6 months after presentation showed the area of excavation to be stable in size. Conclusion FCE can be associated with epiretinal membrane, central serous chorioretinopathy, and age-related macular degeneration. The choroid was thinned out in the area of FCE. PMID:24946847

  13. ICG-assisted blood vessel detection during stereotactic neurosurgery: simulation study on excitation power limitations due to thermal effects in human brain tissue.

    Science.gov (United States)

    Rühm, Adrian; Göbel, Werner; Sroka, Ronald; Stepp, Herbert

    2014-09-01

    Intraoperative blood vessel detection based on intraluminal indocyanin-green (ICG) would allow to minimize the risk of blood vessel perforation during stereotactic brain tumor biopsy. For a fiber-based approach compatible with clinical conditions, the maximum tolerable excitation light power was derived from simulations of the thermal heat load on the tissue. Using the simulation software LITCIT, the temperature distribution in human brain tissue was calculated as a function of time for realistic single-fiber probes (0.72mm active diameter, numerical aperture 0.35, optional focusing to 0.29mm diameter) and for the optimum ICG excitation wavelength of 785nm. The asymptotic maximum temperature in the simulated tissue region was derived for different radiant fluxes at the distal fiber end. Worst case values were assumed for all other parameters. In addition to homogeneous (normal and tumor) brain tissue with homogeneous blood perfusion, models with localized extra blood vessels incorporated ahead of the distal fiber end were investigated. If one demands that destruction of normal brain tissue must be excluded by limiting the tissue heating to 42°C, then the radiant flux at the distal fiber end must be limited to 33mW with and 43mW without focusing. When considering extra blood vessels of 0.1mm diameter incorporated into homogeneously perfused brain tissue, the tolerable radiant flux is reduced to 22mW with and 32mW without focusing. The threshold value according to legal laser safety regulations for human skin tissue is 28.5mW. For the envisaged modality of blood vessel detection, light power limits for an application-relevant fiber configuration were determined and found to be roughly consistent with present legal regulations for skin tissue. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. The pharmacokinetics of cefazolin in patients undergoing elective & semi-elective abdominal aortic aneurysm open repair surgery

    Directory of Open Access Journals (Sweden)

    Roberts Michael S

    2011-02-01

    Full Text Available Abstract Background Surgical site infections are common, so effective antibiotic concentrations at the sites of infection are required. Surgery can lead to physiological changes influencing the pharmacokinetics of antibiotics. The aim of the study is to evaluate contemporary peri-operative prophylactic dosing of cefazolin by determining plasma and subcutaneous interstitial fluid concentrations in patients undergoing elective of semi-elective abdominal aortic aneurysm (AAA open repair surgery. Methods/Design This is an observational pharmacokinetic study of patients undergoing AAA open repair surgery at the Royal Brisbane and Women's Hospital. All patients will be administered 2-g cefazolin by intravenous injection within 30-minutes of the procedure. Participants will have samples from blood and urine, collected at different intervals. Patients will also have a microdialysis catheter inserted into subcutaneous tissue to measure interstitial fluid penetration by cefazolin. Participants will be administered indocyanine green and sodium bromide as well as have cardiac output monitoring performed and tetrapolar bioimpedance to determine physiological changes occurring during surgery. Analysis of samples will be performed using validated liquid chromatography tandem mass-spectrometry. Pharmacokinetic analysis will be performed using non-linear mixed effects modeling to determine individual and population pharmacokinetic parameters and the effect of peri-operative physiological changes on cefazolin disposition. Discussion The study will describe cefazolin levels in plasma and the interstitial fluid of tissues during AAA open repair surgery. The effect of physiological changes to the patient mediated by surgery will also be determined. The results of this study will guide clinicians and pharmacists to effectively dose cefazolin in order to maximize the concentration of antibiotics in the tissues which are the most common site of surgical site infections.

  15. Spectrum of ocular manifestations in CLN2-associated batten (Jansky-Bielschowsky disease correlate with advancing age and deteriorating neurological function.

    Directory of Open Access Journals (Sweden)

    Anton Orlin

    Full Text Available BACKGROUND: Late infantile neuronal ceroid lipofuscinosis (LINCL, one form of Batten's disease is a progressive neurodegenerative disorder resulting from a CLN2 gene mutation. The spectrum of ophthalmic manifestations of LINCL and the relationship with neurological function has not been previously described. METHODS: Patients underwent ophthalmic evaluations, including anterior segment and dilated exams, optical coherence tomography, fluorescein and indocyanine green angiography. Patients were also assessed with the LINCL Neurological Severity Scale. Ophthalmic findings were categorized into one of five severity scores, and the association of the extent of ocular disease with neurological function was assessed. RESULTS: Fifty eyes of 25 patients were included. The mean age at the time of exam was 4.9 years (range 2.5 to 8.1. The mean ophthalmic severity score was 2.6 (range 1 to 5. The mean neurological severity score was 6.1 (range 2 to 11. Significantly more severe ophthalmic manifestations were observed among older patients (p<0.005 and patients with more severe neurological findings (p<0.03. A direct correlation was found between the Ophthalmic Severity Scale and the Weill Cornell Neurological Scale (p<0.002. A direct association was also found between age and the ophthalmic manifestations (p<0.0002, with older children having more severe ophthalmic manifestations. CONCLUSIONS: Ophthalmic manifestations of LINCL correlate closely with the degree of neurological function and the age of the patient. The newly established LINCL Ophthalmic Scale may serve as an objective marker of LINCL severity and disease progression, and may be valuable in the evaluation of novel therapeutic strategies for LINCL, including gene therapy.

  16. Engineering of near infrared fluorescent proteinoid-poly(L-lactic acid) particles for in vivo colon cancer detection.

    Science.gov (United States)

    Kolitz-Domb, Michal; Grinberg, Igor; Corem-Salkmon, Enav; Margel, Shlomo

    2014-08-12

    The use of near-infrared (NIR) fluorescence imaging techniques has gained great interest for early detection of cancer owing to the negligible absorption and autofluorescence of water and other intrinsic biomolecules in this region. The main aim of the present study is to synthesize and characterize novel NIR fluorescent nanoparticles based on proteinoid and PLLA for early detection of colon tumors. The present study describes the synthesis of new proteinoid-PLLA copolymer and the preparation of NIR fluorescent nanoparticles for use in diagnostic detection of colon cancer. These fluorescent nanoparticles were prepared by a self-assembly process in the presence of the NIR dye indocyanine green (ICG), a FDA-approved NIR fluorescent dye. Anti-carcinoembryonic antigen antibody (anti-CEA), a specific tumor targeting ligand, was covalently conjugated to the P(EF-PLLA) nanoparticles through the surface carboxylate groups using the carbodiimide activation method. The P(EF-PLLA) nanoparticles are stable in different conditions, no leakage of the encapsulated dye into PBS containing 4% HSA was detected. The encapsulation of the NIR fluorescent dye within the P(EF-PLLA) nanoparticles improves significantly the photostability of the dye. The fluorescent nanoparticles are non-toxic, and the biodistribution study in a mouse model showed they evacuate from the body over 24 h. Specific colon tumor detection in a chicken embryo model and a mouse model was demonstrated for anti-CEA-conjugated NIR fluorescent P(EF-PLLA) nanoparticles. The results of this study suggest a significant advantage of NIR fluorescence imaging using NIR fluorescent P(EF-PLLA) nanoparticles over colonoscopy. In future work we plan to broaden this study by encapsulating cancer drugs such as paclitaxel and/or doxorubicin, within these biodegradable NIR fluorescent P(EF-PLLA) nanoparticles, for both detection and therapy of colon cancer.

  17. IDIOPATHIC MULTIFOCAL CHOROIDITIS PRESENTING WITH A TRANSIENT PERIPAPILLARY WHITE RING.

    Science.gov (United States)

    Gattoussi, Sarra; Ghadiali, Quraish; Dolz-Marco, Rosa; Freund, K Bailey

    2017-11-22

    We describe with multimodal imaging the presentation and follow-up for a patient with idiopathic multifocal choroiditis and a transient peripapillary white ring. Case report. A 39-year-old Asian woman was initially seen for an evaluation of lattice degeneration in 2015. Her medical history included Graves disease and psoriasis. Best-corrected visual acuity was 20/25 in her right eye and 20/25 in her left eye. Ultra-widefield fundus autofluorescence imaging showed a curvilinear hyperautofluorescent line in her right eye. One year later, the patient returned complaining of floaters in her right eye for 1 month. Her visual acuity was unchanged. Funduscopic examination showed new inflammatory yellowish lesions in the right eye corresponding to hyperreflective sub-retinal pigment epithelium lesions on structural spectral domain optical coherence tomography. Fluorescein angiography showed corresponding late staining of these active lesions. Late-phase indocyanine green angiography showed multiple nummular hypocyanescent dots. Ultra-widefield fundus autofluorescence showed large areas of hyperautofluorescence. The patient was started on a 60-mg oral prednisone taper and demonstrated subsequent regression of the inflammatory lesions. Ten months later, the patient returned emergently with complaints of floaters in both eyes for 2 days and a new temporal scotoma in her left eye. Funduscopic examination demonstrated a white ring around the optic nerve of the left eye corresponding to a hyperautofluorescent lesion. Ultra-widefield fundus autofluorescence showed new areas of hyperautofluorescence in both eyes. Structural spectral domain optical coherence tomography showed new sub-retinal pigment epithelium inflammatory lesions and a disruption of the ellipsoid zone in both eyes. The patient was again treated with a 60-mg oral prednisone taper and demonstrated subsequent restoration of the ellipsoid zone. To our knowledge, this is the first report of a transient annular white

  18. Optical imaging for the diagnosis of oral cancer and oral potentially malignant disorders

    Science.gov (United States)

    Yoshida, K.

    2016-03-01

    Optical Imaging is being conducted as a therapeutic non-invasive. Many kinds of the light source are selected for this purpose. Recently the oral cancer screening is conducted by using light-induced tissue autofluorescence examination such as several kinds of handheld devices. However, the mechanism of its action is still not clear. Therefore basic experimental research was conducted. One of auto fluorescence Imaging (AFI) device, VELscopeTM and near-infrared (NIR) fluorescence imaging using ICG-labeled antibody as a probe were compared using oral squamous cell carcinoma (OSCC) mouse models. The experiments revealed that intracutaneous tumor was successfully visualized as low density image by VELscopeTM and high density image by NIR image. In addition, VELscopeTM showed higher sensitivity and lower specificity than that of NIR fluorescence imaging and the sensitivity of identification of carcinoma areas with the VELscopeTM was good results. However, further more studies were needed to enhance the screening and diagnostic uses, sensitivity and specificity for detecting malignant lesions and differentiation from premalignant or benign lesions. Therefore, additional studies were conducted using a new developed near infrared (NIR) fluorescence imaging method targeting podoplanine (PDPN) which consists of indocyanine green (ICG)-labeled anti-human podoplanin antibody as a probe and IVIS imaging system or a handy realtime ICG imaging device that is overexpressed in oral malignant neoplasm to improve imaging for detection of early oral malignant neoplasm. Then evaluated for its sensitivity and specificity for detection of oral malignant neoplasm in xenografted mice model and compared with VELscopeTM. The results revealed that ICG fluorescence imaging method and VELscopeTM had the almost the same sensitivity for detection of oral malignant neoplasm. The current topics of optical imaging about oral malignant neoplasm were reviewed.

  19. Dual-wavelength optical-resolution photoacoustic microscopy for cells with gold nanoparticle bioconjugates in three-dimensional cultures

    Science.gov (United States)

    Lee, Po-Yi; Liu, Wei-Wen; Chen, Shu-Ching; Li, Pai-Chi

    2016-03-01

    Three-dimensional (3D) in vitro models bridge the gap between typical two-dimensional cultures and in vivo conditions. However, conventional optical imaging methods such as confocal microscopy and two-photon microscopy cannot accurately depict cellular processing in 3D models due to limited penetration of photons. We developed a dualwavelength optical-resolution photoacoustic microscopy (OR-PAM), which provides sufficient penetration depth and spatial resolution, for studying CD8+ cytotoxic T lymphocytes (CTLs) trafficking in an in vitro 3D tumor microenvironment. CTLs play a cardinal role in host defense against tumor. Efficient trafficking of CTLs to the tumor microenvironment is a critical step for cancer immunotherapy. For the proposed system, gold nanospheres and indocyanine green (ICG) have been remarkable choices for contrast agents for photoacoustic signals due to their excellent biocompatibility and high optical absorption. With distinct absorption spectrums, targeted cells with gold nanospheres and ICG respectively can be identified by switching 523-nm and 800-nm laser irradiation. Moreover, we use an x-y galvanometer scanner to obtain high scanning rate. In the developed system, lateral and axial resolutions were designed at 1.6 μm and 5 μm, respectively. We successfully showed that dual-spectral OR-PAM can map either the distribution of CTLs with gold nanospheres at a visible wavelength of 523 nm or the 3D structure of tumor spheres with ICG in an in vitro 3D microenvironment. Our OR-PAM can provide better biological relevant information in cellular interaction and is potential for preclinical screening of anti-cancer drugs.

  20. In vivo two-photon imaging of retina in rabbits and rats.

    Science.gov (United States)

    Jayabalan, Gopal Swamy; Wu, Yi-Kai; Bille, Josef F; Kim, Samuel; Mao, Xiao Wen; Gimbel, Howard V; Rauser, Michael E; Fan, Joseph T

    2018-01-01

    The purpose of this study was to evaluate the retina using near-infrared (NIR) two-photon scanning laser ophthalmoscopy. New Zealand white rabbits, albino rats, and brown Norway rats were used in this study. An autofluorescence image of the retina, including the retinal cells and its associated vasculatures was obtained by a real-time scan using the ophthalmoscope. Furthermore, the retinal vessels, nerve fiber layers and the non-pigmented retina were recorded with two-photon fluorescein angiography (FA); and the choroidal vasculatures were recorded using two-photon indocyanine green angiography (ICGA). Two-photon ICGA was achieved by exciting a second singlet state at ∼398 nm. Simultaneous two-photon FA and two-photon ICGA were performed to characterize the retinal and choroidal vessels with a single injection. The minimum laser power threshold required to elicit two-photon fluorescence was determined. The two-photon ophthalmoscope could serve as a promising tool to detect and monitor the disease progression in animal models. Moreover, these high-resolution images of retinal and choroidal vessels can be acquired in a real-time scan with a single light source, requiring no additional filters for FA or ICGA. The combination of FA and ICGA using the two-photon ophthalmoscope will help researchers to characterize the retinal diseases in animal models, and also to classify the types (classic, occult or mixed) of choroidal neovascularization (CNV) in macular degeneration. Furthermore, the prototype can be adapted to image the retina of rodents and rabbits. Copyright © 2017 Elsevier Ltd. All rights reserved.