WorldWideScience

Sample records for indirect ct venography

  1. Primary research on direct multi-slice spiral CT venography in inferior vena cava

    International Nuclear Information System (INIS)

    Gong Peiyou; Liu Fengli; Ma Xianying; Zhao Li; Wang Liping; Li Xuehua; Li Jian

    2010-01-01

    Objective: To investigate the superiority of direct multi-slice spiral CT venography in inferior vena cava. Methods: Twenty-eight patients performed MSCT venography in inferior vena cava, including 2 cases with both indirect and direct venography, 10 cases with indirect venography, 20 cases with direct venography through unilateral or bilateral lower extremity venous injection. The image quality and enhancement degree of the inferior vena cava were compared in double-blind method. Results: Of 10 cases with indirect venography of inferior vena cava, 1 case was failed due to mild enhancement in inferior vena cava. Image quality was good in 2 cases, poor in 7 cases, no excellent case. Of 20 cases with direct venography of inferior vena cava, the enhancement degree was scored 1, 2 degree in 16, 4 cases respectively and no case was scored 3 degree, the image quality was excellent, good in 16, 4 cases and no case was bad. The success rate was 100%. Conclusion: The image quality of direct MSCT venography in inferior vena cava is better than that of indirect method. (authors)

  2. The Interobserver Agreement between Residents and Experienced Radiologists for Detecting Pulmonary Embolism and DVT with Using CT Pulmonary Angiography and Indirect CT Venography

    International Nuclear Information System (INIS)

    Yavas, Ulas Savas; Calisir, Cuneyt; Ozkan; Ibrahim Ragip

    2008-01-01

    We wanted to prospectively evaluate the interobserver agreement between radiology residents and expert radiologists for interpreting CT images for making the diagnosis of pulmonary embolism (PE). We assessed 112 consecutive patients, from April 2007 to August 2007, who were referred for combined CT pulmonary angiography and indirect CT venography for clinically suspected acute PE. CT scanning was performed with a 64x0.5 collimation multi-detector CT scanner. The CT studies were initially interpreted by the radiology residents alone and then the CT images were subsequently interpreted by a consensus of the resident plus an experienced general radiologist and an experienced chest radiologist. Two of the 112 CTs were unable to be interpreted (1.7%). Pulmonary artery clots were seen on 36 of the thoracic CT angiographies (32%). The interobserver agreement between the radiology residents and the consensus interpretation was good (a kappa index of 0.73). All of the disagreements (15 cases) were instances of overcall by the resident on the initial interpretation. Deep venous thrombosis was detected in 72% (26 of 36) of the patients who had PE seen on thoracic CT. The initial and consensus interpretations of the CT venography images disagreed for two cases (kappa statistic: 0.96). It does not seem adequate to base the final long-term treatment of PE on only the resident's reading, as false positives occurred in 13% of such cases. Timely interpretation of the CT pulmonary angiography and CT venography images should be performed by experienced radiologists for the patients with suspected PE

  3. Floating venous thrombi: diagnosis with spiral-CT-venography

    International Nuclear Information System (INIS)

    Gartenschlaeger, M.; Schmidt, J.A.

    1996-01-01

    Local application of contrast agent into an ipsilateral dorsal foot vein and spiral CT were used to examine 16 consecutive cases with deep venous thrombosis proven at conventional venography; in addition, colour Doppler flow imaging was performed. At conventional venography, 8/16 thrombi appeared to be floating and the remaining 8/16 were adherent to the vessel wall. Spiral-CT showed 15/16 thrombi to be adherent to the vessel wall; the floating thrombus correlated with findings in conventional venography. At colour Doppler flow imaging 3/16 thrombi were considered floating, one of them was discordant to conventional venography. The comparison of conventional venography to spiral-CT demonstrates complete agreement for adherence to vessel wall seen in conventional venography (p=1,0) and significant discordance in cases with free-floating appearance in conventional venography. Adherence of thrombi to the wall of the vessel at conventional venography is in agreement with computed tomography. Conventional venography probably overestimates the prevalence of free floating thrombi. (orig./MG) [de

  4. Floating venous thrombi: diagnosis with spiral-CT-venography; Diagnose flottierender venoeser Thromben mittels Phlebo-Spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Gartenschlaeger, M. [Mainz Univ. (Germany). Klinik fuer Radiologie; Klose, K.J. [Univ. Marburg, Medizinisches Zentrum fuer Innere Medizin, Abt. Poliklinik (Germany); Schmidt, J.A. [Univ. Marburg, Medizinisches Zentrum fuer Radiologie, Abt. fuer Strahlendiagnostik (Germany)

    1996-05-01

    Local application of contrast agent into an ipsilateral dorsal foot vein and spiral CT were used to examine 16 consecutive cases with deep venous thrombosis proven at conventional venography; in addition, colour Doppler flow imaging was performed. At conventional venography, 8/16 thrombi appeared to be floating and the remaining 8/16 were adherent to the vessel wall. Spiral-CT showed 15/16 thrombi to be adherent to the vessel wall; the floating thrombus correlated with findings in conventional venography. At colour Doppler flow imaging 3/16 thrombi were considered floating, one of them was discordant to conventional venography. The comparison of conventional venography to spiral-CT demonstrates complete agreement for adherence to vessel wall seen in conventional venography (p=1,0) and significant discordance in cases with free-floating appearance in conventional venography. Adherence of thrombi to the wall of the vessel at conventional venography is in agreement with computed tomography. Conventional venography probably overestimates the prevalence of free floating thrombi. (orig./MG) [Deutsch] Mittels lokaler Kontrastmittelapplikation in eine ipsilaterale Fussrueckenvene und Spiral-CT wurden 16 konsekutive Faelle konventionell phlebographisch gesicherter Phlebothrombose untersucht, zusaetzlich wurde die farbkodierte Doppler-Ultraschalluntersuchung durchgefuehrt. In der konventionellen Phlebographie waren 8/16 Thromben flottierend, die uebrigen 8/16 wandadhaerent. In der Spiral-CT zeigten sich Wandadhaerenzen in 15/16 Faellen; der nachgewiesene flottierende Thrombus stimmte mit der konventionellen Phlebographie ueberein. Im farbkodierten Doppler-Ultraschall erschienen die Thromben in 3/16 Faellen flottierend, darunter ein von der konventionellen Phlebographie abweichender Befund. Der Vergleich von konventioneller und CT-Phlebographie ergab eine komplette Uebereinstimmung fuer konventionell phlebographisch nachgewiesene Wandadhaerenz und eine signifikante Abweichung

  5. CT-Venography for the diagnosis of deep venous thrombosis of the lower extremities

    Energy Technology Data Exchange (ETDEWEB)

    Matsuhashi, Toshio [Iwaki Kyoritsu Hospital, Fukushima (Japan); Ishii, Kiyoshi; Tsuboi, Masahiro; Saito, Haruo; Ishibashi, Tadashi; Takahashi, Shoki

    2000-12-01

    We evaluated imaging of deep venous thrombosis (DVT) of the lower extremities using CT-Venography. CT-Venography was performed in 11 patients with suspected DVT. This method clearly demonstrated thrombus extension of DVT and collateral circulation. We concluded that CT-Venography was useful in the evaluation of DVT of the lower extremities. (author)

  6. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  7. The diagnostic value of indirect lower limb CT venography in the lower extremity deep venous thrombosis

    International Nuclear Information System (INIS)

    Zhu Li; Guo Youmin; Wang Jianguo; Guo Xiaojuan; Liu Min; Guo Yulin

    2009-01-01

    Objective: To evaluate indirect CT venography (CTV) in the diagnosis of deep venous thrombosis (DVT). Methods: A total of 516 acute pulmonary embolism patients proved by objective test were analyzed retrospectively. Using the results of lower limb compression sonography as reference standard, the sensitivity, specificity, positive predictive value and negative predictive value of indirect CTV were calculated. The agreement between lower extremity venous sonography and indirect CTV were assessed by Kappa analysis. Results: Among 516 patients with acute pulmonary thromboembolism (PTE), 110 patients underwent both CTV and CTPA and lower extremity sonography. DVT were detected by CTV and sonography simultaneously in 48 patients, while no DVT was detected in 39 patients by both examinations. Thirteen patients were diagnosed to have DVT by CTV without sonography detection, and DVT was detected in other 10 patients only by sonography. The sensitivity, specificity, positive predictive value and negative predictive value of indirect CTV was 82.8% (48/58), 75.0% (39/52), 78.7% (48/61) and 79.6% (39/49). The agreement between lower extremity venous sonography and indirect CTV was good for femoropopliteal vein (Kappa value range from 0.874 to 0.914, P=0.000). Thrombi detected by CTV were 62 and 52 respectively, and for sonography were 67 and 51 respectively. For calf veins, the agreement decreased (Kappa value range from 0.464 to 0.584, P=0.000). Thrombi detected by CTV were 6, 25 and 13 respectively, and for sonography were 13, 38 and 19 respectively. The agreement for external iliac vein was poor (Kappa value range from 0.230 to 0.262, P=0.067 and 0.004, respectively). Thrombi detected by CTV were 33, and for sonography were 17. Conclusions: The indirect CTV has high accuracy in the diagnosis of DVT. Combined CTPA and CTV can image pulmonary arteries and lower extremity veins in one examination. Indirect CTV can reveal thrombus in large pelvic veins, which has an advantage

  8. Elaboration of angio-CT protocols and CT venography in the radiology service of Hospital Calderon Guardia

    International Nuclear Information System (INIS)

    Valverde Sanchez, Allan

    2009-01-01

    A review and analysis was made of the existing literature of publications in medical journals of radiology. Angio-CT protocols and venography have been the sources most used in hospitals.The topics to be reviewed are: the pathogenesis and tomographic findings of major vascular pathologies of the aorta at the thoracic, abdominal, peripheral arterial system of the upper and lower limbs; as well as, to level of the inferior vein cava, vascular pathologies in the kidney, hepatic, pulmonary and splanchnic circulation, neck trauma and complications have been associated with vascular injury with CT correlation. CT angiography protocols related to pathology of the chest are focused, also, the abdomen, upper and lower limbs and neck trauma and CT venography protocol for the valuation of the inferior vein cava and the deep veins of the lower limbs have been described. The approach and treatment of vascular pathologies related have been provided. (author) [es

  9. Improving image quality in portal venography with spectral CT imaging

    International Nuclear Information System (INIS)

    Zhao, Li-qin; He, Wen; Li, Jian-ying; Chen, Jiang-hong; Wang, Ke-yang; Tan, Li

    2012-01-01

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  10. Improving image quality in portal venography with spectral CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Li-qin, E-mail: zhaolqzr@sohu.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); He, Wen, E-mail: hewen1724@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Li, Jian-ying, E-mail: jianying.li@med.ge.com [CT Advanced Application and Research, GE Healthcare, 100176 China (China); Chen, Jiang-hong, E-mail: chenjianghong1973@hotmail.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Wang, Ke-yang, E-mail: ke7ke@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Tan, Li, E-mail: Litan@ge.com [CT product, GE Healthcare, 100176 China (China)

    2012-08-15

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  11. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact; Angio TC y flebo TC combinados en el diagnostico de la enfermedad tramboembolica: impacto clinico

    Energy Technology Data Exchange (ETDEWEB)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J. [Complejo Hospitalario Xerar-Cies. Vigo. Pontevedra (Spain)

    2002-07-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs.

  12. Indirect MR venography: contrast medium protocols, postprocessing and combination in diagnosing pulmonary emboli with MRI

    International Nuclear Information System (INIS)

    Kluge, A.; Bachmann, G.; Rominger, M.; Schoenburg, M.

    2004-01-01

    Purpose: Integration of MR venography in a comprehensive MR imaging protocol in patients with suspected pulmonary embolism (PE) and evaluation of contrast media dosage, timing and postprocessing for diagnostic accuracy. Materials and Methods: Fortyeight consecutive inpatients with suspected PE or deep vein thrombosis were examined by MR venography according to one of the following protocols: protocol I: MR venography only, 0.25 mmol/kg bodyweight (BW) Gadopentate dimeglumine(Gd-DTPA) as single dose, bolus timing; protocol II: MR angiography of pulmonary arteries with a cumulative dosage of 0.25 mmol/kg contrast media, modification of coil setting for MR venography without further contrast media application; protocol III: as protocol II but with 0.125 mmol/kg BW, followed by MR venography. Signal-to-noise ratio, contrast-to-noise ratio, number of definable vascular segments and image quality were evaluated. The results were compared to conventional bilateral venography. Results: All MR venography examinations were of diagnostic quality and the examination time was below 10 min. MR venography could be performed in all 48 patients comparted to 43 of 48 patients for conventional venography. Significantly more superficial and deep veins of the leg could be visualized by MR venography (94% compared to 83% for conventional venography). Sensitivity and specificity were 100% and 92%, respectively. Quality differed significantly between 0.125 mmol/kg (protocol III) and 0.25 mmol/kg Gd-DTPA (protocols I and II) while timing did not influence quality (protocol I vs. II). (orig.) [de

  13. The oblique occipital sinus: anatomical study using bone subtraction 3D CT venography.

    Science.gov (United States)

    Shin, Hwa Seon; Choi, Dae Seob; Baek, Hye Jin; Choi, Ho Cheol; Choi, Hye Young; Park, Mi Jung; Kim, Ji Eun; Han, Jeong Yeol; Park, SungEun

    2017-06-01

    An occipital sinus draining into the sigmoid sinus has been termed the oblique occipital sinus (OOS). The frequency, anatomical features, patterns, and relationship with the transverse sinus of the oblique occipital sinus were analyzed in this study. The study included 1805 patients who underwent brain CT angiography during a 3-year period from 2013 to 2015. CT examinations were performed using a 64-slice MDCT system. The OOS was identified in 41 patients (2.3%). There were many anatomical variations in the oblique occipital sinuses. A hypoplastic or aplastic TS was seen in 31 (75.6%) of the 41 patients with OOS. Many anatomical variations in the oblique occipital sinus can be seen on CT venography. Some OOSs function as the main drainage route of the intracranial veins instead of the TS. Thus, careful examination is essential for preoperative evaluation in posterior fossa lesions.

  14. Selecting optimal monochromatic level with spectral CT imaging for improving imaging quality in hepatic venography

    International Nuclear Information System (INIS)

    Sun Jun; Luo Xianfu; Wang Shou'an; Wang Jun; Sun Jiquan; Wang Zhijun; Wu Jingtao

    2013-01-01

    Objective: To investigate the effect of spectral CT monochromatic images for improving imaging quality in hepatic venography. Methods: Thirty patients underwent spectral CT examination on a GE Discovery CT 750 HD scanner. During portal phase, 1.25 mm slice thickness polychromatic images and optimal monochromatic images were obtained, and volume rendering and maximum intensity projection were created to show the hepatic veins respectively. The overall imaging quality was evaluated on a five-point scale by two radiologists. Inter-observer agreement in subjective image quality grading was assessed by Kappa statistics. Paired-sample t test were used to compare hepatic vein attenuation, hepatic parenchyma attenuation, CT value difference between the hepatic vein and the liver parenchyma, image noise, vein-to-liver contrast-to-noise ratio (CNR), the image quality score of hepatic venography between the two image data sets. Results: The monochromatic images at 50 keV were found to demonstrate the best CNR for hepatic vein.The hepatic vein attenuation [(329 ± 47) HU], hepatic parenchyma attenuation [(178 ± 33) HU], CT value difference between the hepatic vein and the liver parenchyma [(151 ± 33) HU], image noise (17.33 ± 4.18), CNR (9.13 ± 2.65), the image quality score (4.2 ± 0.6) of optimal monochromatic images were significantly higher than those of polychromatic images [(149 ± 18) HU], [(107 ± 14) HU], [(43 ±11) HU], 12.55 ± 3.02, 3.53 ± 1.03, 3.1 ± 0.8 (t values were 24.79, 13.95, 18.85, 9.07, 13.25 and 12.04, respectively, P < 0.01). In the comparison of image quality, Kappa value was 0.81 with optimal monochromatic images and 0.69 with polychromatic images. Conclusion: Monochromatic images of spectral CT could improve CNR for displaying hepatic vein and improve the image quality compared to the conventional polychromatic images. (authors)

  15. Dynamic multidetector CT and non-contrast-enhanced MR for right adrenal vein imaging: comparison with catheter venography in adrenal venous sampling

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideki; Seiji, Kazumasa; Kawabata, Masahiro; Satani, Nozomi; Matsuura, Tomonori; Tominaga, Junya; Takase, Kei [Tohoku University Hospital, Department of Diagnostic Radiology, Sendai (Japan); Omata, Kei; Ono, Yoshikiyo; Iwakura, Yoshitsugu; Morimoto, Ryo; Kudo, Masataka; Satoh, Fumitoshi; Ito, Sadayoshi [Tohoku University Hospital, Division of Nephrology, Endocrinology and Vascular Medicine, Sendai (Japan)

    2016-03-15

    To evaluate visualization of the right adrenal vein (RAV) with multidetector CT and non-contrast-enhanced MR imaging in patients with primary aldosteronism. A total of 125 patients (67 men) scheduled for adrenal venous sampling (AVS) were included. Dynamic 64-detector-row CT and balanced steady-state free precession-based non-contrast-enhanced 3-T MR imaging were performed. RAV visualization based on a four-point score was documented. Both anatomical location and variation on cross-sectional imaging were evaluated, and the findings were compared with catheter venography as the gold standard. The RAV was visualized in 93.2 % by CT and 84.8 % by MR imaging (p = 0.02). Positive predictive values of RAV visualization were 100 % for CT and 95.2 % for MR imaging. Imaging score was significantly higher in CT than MR imaging (p < 0.01). The RAV formed a common trunk with an accessory hepatic vein in 16 % of patients. The RAV orifice level on cross-sectional imaging was concordant with catheter venography within the range of 1/3 vertebral height in >70 % of subjects. Success rate of AVS was 99.2 %. Dynamic CT is a reliable way to map the RAV prior to AVS. Non-contrast-enhanced MR imaging is an alternative when there is a risk of complication from contrast media or radiation exposure. (orig.)

  16. MR-Venography Using High Resolution True-FISP

    Energy Technology Data Exchange (ETDEWEB)

    Spuentrup, E. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Buecker, A.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Stuber, M. [Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Philips Med. Syst., Best (Netherlands)

    2001-08-01

    A new fast MR-venography approach using a high resolution True-FISP imaging sequence was investigated in 20 patients suffering from 23 deep vein thromboses. Diagnosis was proven by X-ray venography, CT or ultrasound examination. The presented technique allowed for clear thrombus visualization with a high contrast to the surrounding blood pool even in calf veins. Acquisition time was less than 10 minutes for imaging the pelvis and the legs. No contrast media was needed. The presented high resolution True-FISP MR-veography is a promising non-invasive, fast MR-venography approach for detection of deep venous thrombosis. (orig.) [German] Eine neue schnelle, oertlich hochaufgeloeste MR-Phlebographietechnik mit einer axialen True-FISP Bildgebungssequenz wurde an 20 Patienten mit 23 nach-gewiesenen tiefen Beinvenenthrombosen untersucht. Die Befunde wurden mit einer konventionellen Roentgenphlebographie, einer CT oder einer Sonographie gesichert. Die vorgestellte Technik erlaubte in allen Faellen eine Thrombusdarstellung mit hohem Kontrast zum umgebenden venoesen Blut, wobei aufgrund der hohen Ortsaufloesung auch die Unterschenkelvenen beurteilt werden konnten. Die Datenaufnahmezeit zur Untersuchung des Beckens und der Beine betrug weniger als 10 Minuten. Kontrastmittel wurde nicht benoetigt. Die vorgestellte MR-Phlebographietechnik unter Verwendung einer oertlich hochauf-geloesten True-FISP Sequenz ist eine neue, vielversprechende, nicht-invasive Technik zur Diagnostik der tiefen Bein- und Beckenvenenthrombose. (orig.)

  17. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    International Nuclear Information System (INIS)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong; Kim, Jeong Ho; Park, Chul Hi

    2008-01-01

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean±standard deviation) of the beam hardening artifact was 4.5±0.8 cm in the arthroplastic knees and 3.9±2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients

  18. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong [Inha University, College of Medicine, Incheon (Korea, Republic of); Kim, Jeong Ho; Park, Chul Hi [Gachon University, Gil Medical Center, Incheon (Korea, Republic of)

    2008-02-15

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean{+-}standard deviation) of the beam hardening artifact was 4.5{+-}0.8 cm in the arthroplastic knees and 3.9{+-}2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients.

  19. Comparison of the image qualities of filtered back-projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction for CT venography at 80 kVp

    International Nuclear Information System (INIS)

    Kim, Jin Hyeok; Choo, Ki Seok; Moon, Tae Yong; Lee, Jun Woo; Jeon, Ung Bae; Kim, Tae Un; Hwang, Jae Yeon; Yun, Myeong-Ja; Jeong, Dong Wook; Lim, Soo Jin

    2016-01-01

    To evaluate the subjective and objective qualities of computed tomography (CT) venography images at 80 kVp using model-based iterative reconstruction (MBIR) and to compare these with those of filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) using the same CT data sets. Forty-four patients (mean age: 56.1 ± 18.1) who underwent 80 kVp CT venography (CTV) for the evaluation of deep vein thrombosis (DVT) during 4 months were enrolled in this retrospective study. The same raw data were reconstructed using FBP, ASIR, and MBIR. Objective and subjective image analysis were performed at the inferior vena cava (IVC), femoral vein, and popliteal vein. The mean CNR of MBIR was significantly greater than those of FBP and ASIR and images reconstructed using MBIR had significantly lower objective image noise (p <.001). Subjective image quality and confidence of detecting DVT by MBIR group were significantly greater than those of FBP and ASIR (p <.005), and MBIR had the lowest score for subjective image noise (p <.001). CTV at 80 kVp with MBIR was superior to FBP and ASIR regarding subjective and objective image qualities. (orig.)

  20. Dual Energy CT (DECT) Monochromatic Imaging: Added Value of Adaptive Statistical Iterative Reconstructions (ASIR) in Portal Venography.

    Science.gov (United States)

    Zhao, Liqin; Winklhofer, Sebastian; Jiang, Rong; Wang, Xinlian; He, Wen

    2016-01-01

    To investigate the effect of the adaptive statistical iterative reconstructions (ASIR) on image quality in portal venography by dual energy CT (DECT) imaging. DECT scans of 45 cirrhotic patients obtained in the portal venous phase were analyzed. Monochromatic images at 70keV were reconstructed with the following 4 ASIR percentages: 0%, 30%, 50%, and 70%. The image noise (IN) (standard deviation, SD) of portal vein (PV), the contrast-to-noise-ratio (CNR), and the subjective score for the sharpness of PV boundaries, and the diagnostic acceptability (DA) were obtained. The IN, CNR, and the subjective scores were compared among the four ASIR groups. The IN (in HU) of PV (10.05±3.14, 9.23±3.05, 8.44±2.95 and 7.83±2.90) decreased and CNR values of PV (8.04±3.32, 8.95±3.63, 9.80±4.12 and 10.74±4.73) increased with the increase in ASIR percentage (0%, 30%, 50%, and 70%, respectively), and were statistically different for the 4 ASIR groups (pASIR percentages (pASIR (pASIR addition in DECT portal venography could improve the 70 keV monochromatic image quality.

  1. Optimal Adaptive Statistical Iterative Reconstruction Percentage in Dual-energy Monochromatic CT Portal Venography.

    Science.gov (United States)

    Zhao, Liqin; Winklhofer, Sebastian; Yang, Zhenghan; Wang, Keyang; He, Wen

    2016-03-01

    The aim of this article was to study the influence of different adaptive statistical iterative reconstruction (ASIR) percentages on the image quality of dual-energy computed tomography (DECT) portal venography in portal hypertension patients. DECT scans of 40 patients with cirrhosis (mean age, 56 years) at the portal venous phase were retrospectively analyzed. Monochromatic images at 60 and 70 keV were reconstructed with four ASIR percentages: 0%, 30%, 50%, and 70%. Computed tomography (CT) numbers of the portal veins (PVs), liver parenchyma, and subcutaneous fat tissue in the abdomen were measured. The standard deviation from the region of interest of the liver parenchyma was interpreted as the objective image noise (IN). The contrast-noise ratio (CNR) between PV and liver parenchyma was calculated. The diagnostic acceptability (DA) and sharpness of PV margins were obtained using a 5-point score. The IN, CNR, DA, and sharpness of PV were compared among the eight groups with different keV + ASIR level combinations. The IN, CNR, DA, and sharpness of PV of different keV + ASIR groups were all statistically different (P ASIR and 70 keV + 0% ASIR (filtered back-projection [FBP]) combination, respectively, whereas the largest and smallest objective IN were obtained in the 60 keV + 0% ASIR (FBP) and 70 keV + 70% combination. The highest DA and sharpness values of PV were obtained at 50% ASIR for 60 keV. An optimal ASIR percentage (50%) combined with an appropriate monochromatic energy level (60 keV) provides the highest DA in portal venography imaging, whereas for the higher monochromatic energy (70 keV) images, 30% ASIR provides the highest image quality, with less IN than 60 keV with 50% ASIR. Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  2. Multidetector CT venography and contrast-enhanced MR venography of the inferior mesenteric vein in paediatric extrahepatic portal vein obstruction

    International Nuclear Information System (INIS)

    Chennur, Vikash SrinivasaiahSetty; Sharma, Raju; Gamanagatti, Shivanand; Gupta, Arun Kumar; Bhatnagar, Veereshwar; Vishnubhatla, Sreenivas

    2011-01-01

    Extrahepatic portal vein obstruction (EHPVO) is a common cause of paediatric portal hypertension and the only permanent treatment is shunt surgery. The inferior mesenteric vein (IMV) is a portal venous channel that can be used for the shunt when the splenic vein/superior mesenteric vein is thrombosed or when a lienorenal shunt is not possible. To compare MDCT venography (MDCTV) and contrast-enhanced MR venography (CEMRV) for visualisation of the IMV in children with EHPVO. This was a prospective study of 26 children (4-12 years, median 10 years) who underwent MDCTV and CEMRV. The IMV visualisation was graded using 4- and 2-point scales and the difference in visualisation was assessed by calculating the exact significance probability (P). The IMV was visualised in all children on MDCTV and 25/26 children on CEMRV (96%). The images were diagnostic in 23/26 children (88%) on MDCTV and in 18/26 (69%) children on CEMRV (P = 0.063). MDCTV and CEMRV are comparable for IMV visualisation with a tendency toward MDCTV being superior. (orig.)

  3. Multidetector CT venography and contrast-enhanced MR venography of the inferior mesenteric vein in paediatric extrahepatic portal vein obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Chennur, Vikash SrinivasaiahSetty; Sharma, Raju; Gamanagatti, Shivanand; Gupta, Arun Kumar [All India Institute of Medical Sciences (AIIMS), Department of Radiology, New Delhi (India); Bhatnagar, Veereshwar [AIIMS, Department of Paediatric Surgery, New Delhi (India); Vishnubhatla, Sreenivas [AIIMS, Department of Biostatistics, New Delhi (India)

    2011-03-15

    Extrahepatic portal vein obstruction (EHPVO) is a common cause of paediatric portal hypertension and the only permanent treatment is shunt surgery. The inferior mesenteric vein (IMV) is a portal venous channel that can be used for the shunt when the splenic vein/superior mesenteric vein is thrombosed or when a lienorenal shunt is not possible. To compare MDCT venography (MDCTV) and contrast-enhanced MR venography (CEMRV) for visualisation of the IMV in children with EHPVO. This was a prospective study of 26 children (4-12 years, median 10 years) who underwent MDCTV and CEMRV. The IMV visualisation was graded using 4- and 2-point scales and the difference in visualisation was assessed by calculating the exact significance probability (P). The IMV was visualised in all children on MDCTV and 25/26 children on CEMRV (96%). The images were diagnostic in 23/26 children (88%) on MDCTV and in 18/26 (69%) children on CEMRV (P = 0.063). MDCTV and CEMRV are comparable for IMV visualisation with a tendency toward MDCTV being superior. (orig.)

  4. Dual Energy CT (DECT Monochromatic Imaging: Added Value of Adaptive Statistical Iterative Reconstructions (ASIR in Portal Venography.

    Directory of Open Access Journals (Sweden)

    Liqin Zhao

    Full Text Available To investigate the effect of the adaptive statistical iterative reconstructions (ASIR on image quality in portal venography by dual energy CT (DECT imaging.DECT scans of 45 cirrhotic patients obtained in the portal venous phase were analyzed. Monochromatic images at 70keV were reconstructed with the following 4 ASIR percentages: 0%, 30%, 50%, and 70%. The image noise (IN (standard deviation, SD of portal vein (PV, the contrast-to-noise-ratio (CNR, and the subjective score for the sharpness of PV boundaries, and the diagnostic acceptability (DA were obtained. The IN, CNR, and the subjective scores were compared among the four ASIR groups.The IN (in HU of PV (10.05±3.14, 9.23±3.05, 8.44±2.95 and 7.83±2.90 decreased and CNR values of PV (8.04±3.32, 8.95±3.63, 9.80±4.12 and 10.74±4.73 increased with the increase in ASIR percentage (0%, 30%, 50%, and 70%, respectively, and were statistically different for the 4 ASIR groups (p<0.05. The subjective scores showed that the sharpness of portal vein boundaries (3.13±0.59, 2.82±0.44, 2.73±0.54 and 2.07±0.54 decreased with higher ASIR percentages (p<0.05. The subjective diagnostic acceptability was highest at 30% ASIR (p<0.05.30% ASIR addition in DECT portal venography could improve the 70 keV monochromatic image quality.

  5. CT portal venography manifestations of portal collateral circulation in patients with portal hypertension due to cirrhosis

    International Nuclear Information System (INIS)

    Ni Ming; Lv Weifu; Deng Kexue

    2009-01-01

    Objective: To analyze CT portal venography (CTPV) manifestations of portal collateral circulation in patients with cirrhosis by using a 16-detector row spiral CT scanner. Methods: CTPV was performed in 36 patients with portal hypertension due to cirrhosis, the diagnosis was proved by clinical data, hepatic function findings and imaging signs. By using post-processing reconstruction technique, 3D images of portal venous system and portal collateral circulation were obtained. Results: CTPV images displayed the portal venous system and its collateral circulation stereoscopically. Of 36 patients, left gastric varices were seen in 29(80.6%), lower esophageal varices in 18(50.0%), short gastric or posterior gastric varices in 15(41.7%), paraesophageal varices in 9(25.0%), gastro-renal or splenorenal shunts in 8(22.2%), spongelike transformation of portal vein in 7(19.4%), paraumbilical and abdominal wall varices in 6(16.7%), congenital cavernous in 6(16.7%) and paravertebral venous shunts in 4(11.1%). Conclusion: CTPV can well display the site, extent and severity of the portal collateral circulation in patients with portal hypertension due to cirrhosis,which is of great clinical importance for judging the patient's condition, for selecting therapeutic protocols and for estimating prognosis. (authors)

  6. Comparison radiation dose of Z-axis automatic tube current modulation technique with fixed tube current multi-detector row CT scanning of lower extremity venography

    International Nuclear Information System (INIS)

    Yoo, Beong Gyu; Kweon, Dae Cheol; Lee, Jong Seok; Jang, Keun Jo; Jeon, Sang Hwan; Kim, Yong Soo

    2007-01-01

    Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of Multi-Detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, 70∼450 mA). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, Z-axis modulation resulted in reduction of CTDIvol (range, -6.5%∼-35.6%) and DLP (range,-0.2%∼-20.2%). Compared with manually selected fixed tube current, Z-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography

  7. Subtraction MR venography acquired from time-resolved contrast-enhanced MR angiography: Comparison with phase-contrast MR venography and single-phase contrast-enhanced MR venography

    International Nuclear Information System (INIS)

    Jang, Jin Hee; Kim, Bum Soo; KIm, Bom Yi; Choi, Hyun Seok; Jung, So Lyung; Ahn, Kook Jin; Sung, Ji Kyeong

    2015-01-01

    To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). Subtraction magnetic

  8. Intraosseous Venography with Carbon Dioxide in Percutaneous Vertebroplasty: Carbon Dioxide Retention in Renal Veins

    International Nuclear Information System (INIS)

    Komemushi, Atsushi; Tanigawa, Noboru; Kariya, Shuji; Kojima, Hiroyuki; Shomura, Yuzo; Tokuda, Takanori; Nomura, Motoo; Terada, Jiro; Kamata, Minoru; Sawada, Satoshi

    2008-01-01

    The objective of the present study was to determine the frequency of gas retention in the renal vein following carbon dioxide intraosseous venography in the prone position and, while citing references, to examine its onset mechanisms. All percutaneous vertebroplasties performed at our hospital from January to December 2005 were registered and retrospectively analyzed. Of 43 registered procedures treating 79 vertebrae, 28 procedures treating 54 vertebrae were analyzed. Vertebral intraosseous venography was performed using carbon dioxide as a contrast agent in all percutaneous vertebroplasty procedures. In preoperative and postoperative vertebral CT, gas retention in the renal vein and other areas was assessed. Preoperative CT did not show gas retention (0/28 procedures; 0%). Postoperative CT confirmed gas retention in the renal vein in 10 of the 28 procedures (35.7%). Gas retention was seen in the right renal vein in 8 procedures (28.6%), in the left renal vein in 5 procedures (17.9%), in the left and right renal veins in 3 procedures (10.7%), in vertebrae in 22 procedures (78.6%), in the soft tissue around vertebrae in 14 procedures (50.0%), in the spinal canal in 12 procedures (42.9%), and in the subcutaneous tissue in 5 procedures (17.9%). In conclusion, in our study, carbon dioxide gas injected into the vertebra frequently reached and remained in the renal vein.

  9. CASE SERIES Multi-detector computer tomography venography ...

    African Journals Online (AJOL)

    in the curved coronal plane with particular reference to the course of the common and external iliac veins through the pelvis. Axial venous. Aim. To evaluate the role of multi-detector computer tomography venography (MDCTV), compared with conventional venography, as a diagnostic tool in the management of patients with ...

  10. Indirect MR venography: contrast medium protocols, postprocessing and combination in diagnosing pulmonary emboli with MRI; Indirekte MR-Phlebografie: Kontrastmittelprotokolle, Nachverarbeitung und Kombination mit Lungenemboliediagnostik in der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Kluge, A.; Bachmann, G. [Diagnostische Radiologie, Kerckhoff-Klinik, Bad Nauheim (Germany); Rominger, M. [Diagnostische Radiologie, Phillips-Univ. Marburg (Germany); Schoenburg, M. [Herzchirurgie, Kerckhoff-Klinik, Bad Nauheim (Germany)

    2004-07-01

    Purpose: Integration of MR venography in a comprehensive MR imaging protocol in patients with suspected pulmonary embolism (PE) and evaluation of contrast media dosage, timing and postprocessing for diagnostic accuracy. Materials and Methods: Fortyeight consecutive inpatients with suspected PE or deep vein thrombosis were examined by MR venography according to one of the following protocols: protocol I: MR venography only, 0.25 mmol/kg bodyweight (BW) Gadopentate dimeglumine(Gd-DTPA) as single dose, bolus timing; protocol II: MR angiography of pulmonary arteries with a cumulative dosage of 0.25 mmol/kg contrast media, modification of coil setting for MR venography without further contrast media application; protocol III: as protocol II but with 0.125 mmol/kg BW, followed by MR venography. Signal-to-noise ratio, contrast-to-noise ratio, number of definable vascular segments and image quality were evaluated. The results were compared to conventional bilateral venography. Results: All MR venography examinations were of diagnostic quality and the examination time was below 10 min. MR venography could be performed in all 48 patients comparted to 43 of 48 patients for conventional venography. Significantly more superficial and deep veins of the leg could be visualized by MR venography (94% compared to 83% for conventional venography). Sensitivity and specificity were 100% and 92%, respectively. Quality differed significantly between 0.125 mmol/kg (protocol III) and 0.25 mmol/kg Gd-DTPA (protocols I and II) while timing did not influence quality (protocol I vs. II). (orig.) [German] Ziel: Integration der MR-Phlebografie in ein umfassendes Konzept der MRT-Diagnostik bei Verdacht auf Lungenembolie (LE). Untersuchung des Einflusses von Kontrastmittelmenge, -bolusform und Verzoegerungszeit sowie der Nachverarbeitung auf die diagnostische Qualitaet von MR-Phlebografien. Material und Methode: Bei 48 konsekutiven stationaeren Patienten mit Verdacht auf Beinvenenthrombose (TVT

  11. Hypoadrenia following adrenal venography in Cushing's disease

    International Nuclear Information System (INIS)

    Goth, M.; Szilagy, G.; Irsy, G.; Szabolcs, I.; Berentey, E.; Molnar, F.; Magyar, E.

    1984-01-01

    Three patients with Cushing's disease are reported. In two patients the hyperfunction of the adrenal glands creased following selective adrenal venography, moreover hypoadrenia has developed. In the third case necrosis following venography was proved by surgery and confirmed by histology. Regarding the therapeutic possibilities of Cushing's diesease the use of this diagnostic procedure is taken into consideration but not recommended. (orig.)

  12. Venous thromboembolism: Additional diagnostic value and radiation dose of pelvic CT venography in patients with suspected pulmonary embolism

    International Nuclear Information System (INIS)

    Reichert, Miriam; Henzler, Thomas; Krissak, Radko; Apfaltrer, Paul; Huck, Kurt; Buesing, Karen; Sueselbeck, Tim; Schoenberg, Stefan O.; Fink, Christian

    2011-01-01

    Purpose: To assess the additional diagnostic value of indirect CT venography (CTV) of the pelvis and upper thighs performed after pulmonary CT angiography (CTA) for the diagnosis of venous thromboembolism (VTE). Materials and methods: In a retrospective analysis, the radiology information system entries between January 2003 and December 2007 were searched for patients who received pulmonary CTA and additional CTV of the pelvis and upper thighs. Of those patients, the radiology reports were reviewed for the diagnosis of pulmonary embolism (PE) and deep venous thrombosis (DVT) in the pelvic veins and veins of the upper thighs. In cases with an isolated pelvic thrombosis at CTV (i.e. which only had a thrombosis in the pelvic veins but not in the veins of the upper thigh) ultrasound reports were reviewed for the presence of DVT of the legs. The estimated radiation dose was calculated for pulmonary CTA and for CTV of the pelvis. Results: In the defined period 3670 patients were referred to our institution for exclusion of PE. Of those, 642 patients (353 men, 289 women; mean age, 65 ± 15 years, age range 18-98 years) underwent combined pulmonary CTA and CTV. Among them, PE was found in 227 patients (35.4%). In patients without PE CTV was negative in all cases. In patients with PE, CTV demonstrated pelvic thrombosis in 24 patients (3.7%) and thrombosis of the upper thighs in 43 patients (6.6%). Of those patients 14 (2.1%) had DVT in the pelvis and upper thighs. In 10 patients (1.5%) CTV showed an isolated pelvic thrombosis. Of those patients ultrasound reports were available in 7 patients, which revealed DVT of the leg veins in 5 cases (1%). Thus, the estimated prevalence of isolated pelvic thrombosis detected only by pelvic CTV ranges between 1-5/642 patients (0.1-0.7%). Radiation dose ranges between 4.8 and 9.7 mSv for additional CTV of the pelvis. Conclusion: CTV of the pelvis performed after pulmonary CTA is of neglectable additional diagnostic value for the

  13. Diagnostic value of computed tomographic findings of nutcracker syndrome: Correlation with renal venography and renocaval pressure gradients

    International Nuclear Information System (INIS)

    Kim, Kyung Won; Cho, Jeong Yeon; Kim, Seung Hyup; Yoon, Jeong-Hee; Kim, Dae Sik; Chung, Jin Wook; Park, Jae Hyung

    2011-01-01

    Purpose: To evaluate the diagnostic values of CT findings of nutcracker syndrome (NCS). Methods and materials: Twenty seven subjects that underwent CT and renal venography, were divided into three groups based on the venographic renocaval pressure gradient (PG) and collateral veins of the left renal vein (LRV): non-compensated NCS patients with PG ≥ 3 mm Hg (group 1, n = 12), partially compensated NCS patients with borderline PG (1 2 test). Mean values of all quantitative CT parameters differed significantly only between groups 1 and 3 (P < .05, one-way ANOVA test). For differentiating the non-compensated NCS from the control group, the beak sign showed 91.7% sensitivity and 88.9% specificity. Of the various CT parameters, the beak sign and LRV diameter ratio of ≥4.9 showed the greatest diagnostic accuracy (AUC 0.903, ROC analysis). Conclusion: Beak sign of the LRV and CT findings can be useful in diagnosing the non-compensated NCS.

  14. Cushing's syndrome with an apparently normal CT scan

    International Nuclear Information System (INIS)

    Vlahos, L.; Strigaris, K.; Aliferopoulos, D.; Pontifex, G.

    1981-01-01

    A case of Cushing's syndrome is described in which the CT scan was considered as normal. The diagnosis was established with selective venography and blood sampling and was verified surgically. (orig.)

  15. MR venography of the abdomen

    International Nuclear Information System (INIS)

    Alfke, H.; Ishaque, N.; Froelich, J.J.; Klose, K.J.

    1998-01-01

    Purpose: To evaluate the image quality of magnetic resonance venography (MRV) of pelvic and abdominal veins. Methods: A retrospective analysis of all MRV between 1993 and 1996 was conducted. A 2D-FLASH-TOF without breath hold and with arterial presaturation was used. All venous segments have been assessed for the quality of visualisation and an overall image quality was determined. 43% of our patients h[ malignant disease and phlebothrombosis h[ alre[y been diagnosed in 64%. Results: 126 examinations and 1696 venous segments were analysed. The overall quality of the examinations was good, however one examination was non diagnostic because of motion artefacts. Vessels along the vertical axis were good visualised in over 90%. Most important reasons for insufficient visualisation were breathing, motion and metal artefacts as well as compression and displacement of veins due to tumour disease. Conclusions: Magnetic resonance venography without breath hold TOF-technique is practical and robust for routine clinical applications. (orig.) [de

  16. Delineation of calf deep veins using 2D-TOF MR venography without contrast media. Efficacy of tourniquet and leg-warming

    International Nuclear Information System (INIS)

    Nagayoshi, Kensuke; Okada, Munemasa; Monzen, Yoshio; Kimura, Shojiro; Hamanaka, Yoshiharu; Ochi, Makoto; Hayashi, Kuniaki.

    1997-01-01

    We evaluated the imaging quality of 2D-TOF MR venography of the lower part of the leg and the efficacy of a tourniquet around the knee and leg-warming. In 8 healthy volunteers, MR venography was carried out under the following four conditions: usual MR venography, MR venography with tourniquet around the knee, MR venography after leg-warming and MR venography with tourniquet after leg-warming. Our results suggested that MR venography with tourniquet after leg-warming is best suited for imaging the veins of the leg. We also compared the diagnostic image quality of MR venography and conventional contrast venography in 7 patients with varices. The results showed no significant differences between the two methods. We conclude that MR venography with tourniquet after leg-warming is a technique that provides reliable information about the veins of the leg. (author)

  17. Gd-DTPA-enhanced MR venography for varicose veins of the calf

    International Nuclear Information System (INIS)

    Kohata, Yoshiko; Naito, Akira; Ito, Katuhide.

    1995-01-01

    2D time-of-flight MR venography (2D TOF MRV) was performed in 16 patients (25 calves) with varicose veins and 2 volunteers (4 calves), and compared with venography. Sequential SPGR (TR/TE/FA=45 ms/7 ms/60deg) transverse images and/or GRASS (TR/TE/FA=100 ms/13 ms/60deg) transverse images were obtained for MRV. Superior presaturation pulse (S-SAT) was placed in 21 calves, and 0.05 mmol/kg Gd-DTPA was used in all calves. Projection MRVs were generated with maximum intensity projection (MIP) reconstruction. Regarding sequence parameter, S-SAT was useful to eliminate signal from artery that would obscure the signal of deep veins. The detectability of deep veins was improved with the use of S-SAT. In the comparison with venography, MRV could more clearly demonstrate varicose veins more than 5 mm in diameter and their drainage veins than venography. But it could not so clearly demonstrate deep veins as venography. It could not detect fine varicose veins less than 5 mm in diameter and connecting veins with valve insufficiency. In the examination of varicose veins, detection of deep veins, large varicose veins and their main drainage veins is clinically important, because diagnosis of patency of deep veins and dilatation of the drainage veins is necessary to choose the treatment, concluding conservative therapy, stripping and sclerotherapy. However, detection of fine varicose veins and connecting veins are not so important because those veins seldom need treatment. MRV was not so suitable for detection of deep veins, but very useful for detection of varicose veins more than 5 mm in diameter and their main drainage veins. In conclusion, MRV is non-invasive and effective method in varicose veins of calf, and it can take the place of venography with the improvement of deep vein detectability. (author)

  18. Adrenal hormones before and after venography during adrenal venous sampling: a self-controlled study.

    Science.gov (United States)

    Koike, Yuya; Matsui, Seishi; Omura, Masao; Makita, Kohzoh; Obara, Alfonso W D; Moriya, Nobukazu; Nishikawa, Tetsuo

    2017-03-01

    A stress reaction involving increased adrenal hormone release occurs when starting adrenal venous sampling (AVS). The purpose of the present study was to investigate the effect of single shot venography on adrenal hormone production during AVS. This was a prospective self-controlled study. We enrolled 54 consecutive patients (21 men, 33 women; mean age 52 ± 11 years) with primary aldosteronism who underwent AVS from May 2014 to February 2015. Under non-stimulated conditions, blood samples were obtained from a common trunk of the left adrenal vein before and after single shot venography. The initial plasma aldosterone and cortisol concentration (PAC and PCC) were compared with those measured after venography for each patient. PAC and PCC were slightly but significantly decreased between before and after venography (after log transformation 2.12 ± 0.73 vs 2.07 ± 0.72, P = 0.00066, 1.89 ± 0.52 vs 1.83 ± 0.53, P = 0.00031, respectively). During non-stimulated left AVS, adrenal hormone secretion was slightly but significantly decreased after venography, similar to the normal time-related stress reaction. Venography did not increase the adrenal hormone secretion.

  19. Where is the most common site of DVT? Evaluation by CT venography

    International Nuclear Information System (INIS)

    Yoshimura, Norihiko; Hori, Yoshiro; Horii, Yosuke; Takano, Toru; Ishikawa, Hiroyuki; Aoyama, Hidefumi

    2012-01-01

    Our aim was to clarify the common site of deep venous thrombosis (DVT) in patients suspected of having pulmonary embolism using computed tomography pulmonary angiography with computed tomography venography (CTV). We evaluated 215 patients. For all studies, 100 ml of 370 mg I/ml nonionic contrast material was administered. CTV were scanned with helical acquisition starting at 3 min in four-slice multidetector-row computed tomography (MDCT) or 5 min in 64-MDCT after the start of contrast material injection. The site of DVT was divided into iliac vein, femoral vein, popliteal vein, or calf vein. Calf vein was divided into muscular (soleal and gastrocnemius) and nonmuscular (anterior/posterior tibial and peroneal) veins. The 2 x 2 chi-square test was used. One hundred and thirty-seven patients showed DVT; the muscular calf vein was more prevalent than other veins (P<0.01). Our study showed that the most common site of DVT was the muscular calf vein. (author)

  20. Cerebral sinus venography in the dog: a new technique

    International Nuclear Information System (INIS)

    Pluhar, G.E.; Tucker, R.L.; Gavin, P.R.; Bagley, R.S.; Takeuchi, M.

    1997-01-01

    A new method of performing cerebral sinus venography was developed that opacifies both the ventral and most of the dorsal venous sinus systems, A pediatric angiographic catheter was introduced into the external jugular vein and advanced to the level of the temporal sinus, Iodinated contrast medium was injected manually and radiographs were made, Subtraction radiography was used to visualize vessels filled with contrast medium, Venography was simple and relatively non-invasive and was considered safe, The technique was used to confirm occlusion of the transverse venous sinus in healthy dogs that had undergone radical craniectomies

  1. Radionuclide venography of lower limbs by subcutaneous injection; A clinical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Chung-Chieng; Jong, Shiang-Bin (Kaohsiung Medical Coll., Taiwan (China))

    1993-02-01

    SC-RNV, radionuclide venography by subcutaneous injection of Tc-99m pertechnetate at acupuncture points K-3, a new alternative of lower limb venography, was recently developed in our clinical laboratory. In some of the previous studies, we have proved its superiority to radionuclide venography by intravenous injection. The current investigation was conducted to understand the reliability of SC-RNV in the diagnosis of deep vein thrombosis (DVT). Fifty-seven cases with lower leg edema, from November 1989 through October 1990, received both SC-RNV and duplex US for causative evaluation. As a result of duplex US, 26 were considered normal (non-DVT), 19 were classified as unilateral DVT, and 12 as bilateral DVT. In nineteen cases (61%, 19/31) with DVT also a XCT and/or a CV (contrast venography) was taken, that showed compatible results. All of the non-DVT had a normal pattern of SC-RNV, all of the unilateral DVT had unilateral impairment of deep vein drainage in SC-RNV, and all of the bilateral DVT had impaired deep venous drainage bilaterally in SC-RNV. It is therefore, concluded that SC-RNV is one of the best choices among available non-invasive lower-limb venographic methods. (author).

  2. Contrast-enhanced magnetic resonance venography in pediatric patients with chronic kidney disease: initial experience with ferumoxytol

    International Nuclear Information System (INIS)

    Luhar, Aarti; Khan, Sarah; Ghahremani, Shahnaz; Griggs, Rachel; Hall, Theodore R.; Finn, J.P.; Zaritsky, Joshua; Salusky, Isidro

    2016-01-01

    Ferumoxytol is an ultra-small superparamagnetic iron oxide (USPIO) particle that is FDA-approved for parenteral treatment of iron deficiency anemia in adults with chronic kidney disease. Because of the association between gadolinium-based contrast agents and nephrogenic systemic fibrosis in patients with severe chronic kidney disease, we sought to evaluate the diagnostic role of ferumoxytol-enhanced MR venography in children with chronic kidney disease. Twenty children underwent 22 high-resolution ferumoxytol-enhanced MR venography examinations at 3.0 T. High-resolution 3-D contrast-enhanced imaging was performed at a minimum of 3 time points following injection of ferumoxytol at a total dose of 4 mg/kg. Two blinded pediatric radiologists independently scored six named veins on ferumoxytol-enhanced MR venography examinations according to a three-point subjective score, where a score ≥2 was considered diagnostic. Additionally, all relevant venous structures in the included field of view were analyzed for occlusive or non-occlusive thrombosis, compression and presence of collaterals. All patients underwent ferumoxytol-enhanced MR venography successfully and without adverse event. The overall scores of the reviewing radiologists for all venous structures were 2.7-2.9. In all cases, the reviewers were confident basing their diagnoses on the ferumoxytol-enhanced MR venography findings. In 12 of 22 examinations, findings on follow-up imaging or invasive procedures were available to correlate with the findings on ferumoxytol-enhanced MR venography. There was complete concordance between the findings from follow-up imaging and invasive procedures with findings from ferumoxytol-enhanced MR venography. Ferumoxytol holds promise as a powerful alternative to gadolinium-based contrast agents for reliable, high-resolution MR venography in children with chronic kidney disease. (orig.)

  3. Multi-detector computer tomography venography (MDCTV) as a ...

    African Journals Online (AJOL)

    MDCTV), compared with conventional venography, as a diagnostic tool in the management of patients with atypical, complicated and/or recurrent varicose veins. Materials and methods. Retrospective review of 21 patients who had undergone ...

  4. Direct contrast-enhanced MR venography in the diagnosis of May-Thurner Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Gurel, Kamil, E-mail: kamilgurel@hotmail.com [Baskent University, School of Medicine, Adana Medical and Research Center, Department of Radiology (Turkey); Gurel, Safiye; Karavas, Erdal [Abant Izzet Baysal University, Izzet Baysal School of Medicine, Department of Radiology (Turkey); Buharalioglu, Yavuz; Daglar, Bahadir [Abant Izzet Baysal University, Izzet Baysal School of Medicine, Department of Cardiovascular Surgery (Turkey)

    2011-11-15

    Visualization of lower extremity veins with MR venography still needs improvement. The latest advancement is direct contrast-enhanced 3D MR venography which is based on display of venous system during direct injection of paramagnetic extracellular contrast agent into pedal veins. We used automated injection of contrast agent with a power injector makings this application simpler and faster, achieved to show the iliac vein compression syndrome and post-thrombotic changes of the left iliac and femoral veins.

  5. Radionuclide venography of lower limbs by subcutaneous injection; Comparison with venography by intravenous injection

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Chung-Chieng; Jong, Shiang-Bin (Kaohsiung Medical College, Kaohsiung (Taiwan))

    1989-11-01

    We have proved that subcutaneous injection (SC) of a small dose of Tc-99m pertechnetate (1 to 2 mCi: 37 to 74 MBq) at acupuncture points (K-3 and B-60) may offer an alternative method of radionuclide venography (RNV) of the lower limbs. In this study, we compared intravenous (IV) RNV and SC-RNV in 22 consecutive cases with typical signs and symptoms suggesting venous abnormality of the lower limb(s) from March to May 1988. They are 11 male and 11 female, aged 47.7{plus minus}15.7 years. Among the 44 limbs of the 22 cases, 4 were normal, 12 (27.3%) were found to have varicose veins in the legs only, 18 (40.9%) had partial stenosis of the deep veins (14 poplito-tibial and 4 superficial femoral), and 13 (29.6%) had complete stenosis of the deep veins (4 poplito-tibial, 1 superficial femoral and 8 ilio-femoral). SC-RNV showed almost the same results as IV-RNV in 21 (47.7%), superior to IV-RNV in 22 (50%) (including 4.6% failure of IV-RNV), and inferior to IV-RNV in 1 (2.3%). We conclude that SC-RNV is definitely an alternative method of lower-limb venography. Since it is in most cases superior to IV-RNV, we suggest that it can take the place of IV-RNV in routine work. (author) 62 refs.

  6. Lower extremity venography with iohexol: results and complications

    NARCIS (Netherlands)

    Lensing, A. W.; Prandoni, P.; Büller, H. R.; Casara, D.; Cogo, A.; ten Cate, J. W.

    1990-01-01

    The frequency of side effects of a nonionic contrast agent (iohexol) was studied in 463 consecutive patients who underwent venography for clinically suspected deep-vein thrombosis (DVT) and compared with the frequency of adverse reactions of another series in which patients received either the same

  7. Trombose venosa profunda e suspeita de tromboembolismo pulmonar: avaliação simultânea por meio de angiotomografia pulmonar e venotomografia combinadas Deep venous thrombosis with suspected pulmonary embolism: simultaneous evaluation using combined CT venography and pulmonary CT angiography

    Directory of Open Access Journals (Sweden)

    Laura de Moraes Gomes

    2006-02-01

    alone. Among the 23 cases of PE, 15 (65.2% had concomitant DVT whereas 8 (34.8% had only PE. Among the 24 cases of DVT, 15 (62.5% had associated PE and 9 (37.5% had DVT alone. CONCLUSION: The results showed a strong relationship between PE and DVT, as well as the importance of investigating DVT in cases with suspected PE and the benefits of performing indirect CT venography after pulmonary CT angiography as a single examination alternative method for simultaneous investigation of PE and DVT.

  8. Multidetector CT portal venography in evaluation of portosystemic collateral vessels

    International Nuclear Information System (INIS)

    Agarwal, A.; Jain, M.

    2008-01-01

    This essay shows the usefulness of multidetector CT angiography for evaluation of the splenoportal venous system, which is essential in the management of patients with portal hypertension and its complications, such as portal vein thrombosis. By providing scanning with reconstruction of thin axial source images and reformatting into thicker multiplanar reformats, multidetector CT can help to determine the extent and location of portosystemic collateral vessels in patients with portal hypertension and is probably the optimal imaging technique in this setting.

  9. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography.

    Science.gov (United States)

    Owen, Joshua M; Gaba, Ron Charles

    2016-01-01

    The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US), and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS) dysfunction. Forty-one patients (M:F 30:11, median age 55 years) who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding) were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s), absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77%) patients were symptomatic, 33/52 (64%) US examinations were abnormal, and 20/52 (38%) TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52), while the agreement between US and shunt venography was 65% (34/52). Clinical symptoms and the US concurred in 60% (31/52) of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20) and 85% (17/20), respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32) for venographically abnormal shunts. Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  10. Diagnostic performance of CT and MRI on the detection of symptomatic intracranial dural arteriovenous fistula: a meta-analysis with indirect comparison

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yen-Heng [National Taiwan University, Institute of Epidemiology and Preventive Medicine, Taipei (China); National Taiwan University Hospital in Taipei and Yuan-Lin Branch, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China); Lin, Hsien-Ho [National Taiwan University, Institute of Epidemiology and Preventive Medicine, Taipei (China); Liu, Hon-Man; Lee, Chung-Wei; Chen, Ya-Fang [National Taiwan University Hospital in Taipei and Yuan-Lin Branch, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China)

    2016-08-15

    This study aims to review the diagnostic performance of computed tomography (CT) and magnetic resonance imaging (MRI) in symptomatic dural arteriovenous fistula (DAVF). EMBASE, PubMed, and Cochrane Library were searched until April 2015 for studies which compared CT, MRI, or both with angiography for the detection of DAVF. The diagnostic performances of MRI and CT were indirectly compared using modality as a covariate in the analysis. Thirteen studies met our inclusion criteria. MRI had a sensitivity of 0.90 (95 % confidence interval (CI) = 0.83-0.94) and specificity of 0.94 (95 % CI = 0.90-0.96). CT had a sensitivity of 0.80 (95 % CI = 0.62-0.90) and specificity of 0.87 (95 % CI = 0.74-0.94). MRI showed better diagnostic performance than CT (p = 0.02). Contrast medium use and time-resolved MR angiography did not improve MRI diagnostic performance (p = 0.31 and 0.44, respectively). Both CT and MRI had good diagnostic performance. MRI was better than CT on the detection of symptomatic intracranial dural arteriovenous fistula in the indirect comparison. (orig.)

  11. CT cavography: The diagnosis of ilio-caval thrombosis by contrast injection into the foot

    International Nuclear Information System (INIS)

    Bostel, F.; Hauger, W.

    1988-01-01

    CT permits demonstration of thrombus in the iliac veins and inferior vena cava by injecting contrast material into vein in the dorsum of the foot. This technique, called CT covography in this paper, has advantages over conventional venography or DSA and also over sonography. It is indicated following phlebographic demonstration of recent pelvic thrombosis and for demonstrating tumour thrombi in patients with carcinomas of the kidney. (orig.) [de

  12. Collateral pathways in lumbar epidural venography

    International Nuclear Information System (INIS)

    Thijssen, H.O.M.; Ike, B.W.; Chevrot, A.; Bijlsma, R.

    1982-01-01

    Opacification of collateral pathways other than the central channels is very rare in lumbar epidural venography. Two cases of opacification of the inferior mesenteric vein following extravasation of contrast medium at the tip of the lateral sacral vein catheter are reported. One case is presented in which filling of normal parametrial venous plexuses and the left ovarian vein occurred as a consequence of incompetent or absent valves in the internal iliac vein. The literature containing comparable collateral flow patterns in disease is reviewed. The significance of the phlebographic features in our cases is discussed. (orig.)

  13. Transjugular Intrahepatic Portosystemic Shunt Dysfunction: Concordance of Clinical Findings, Doppler Ultrasound Examination, and Shunt Venography

    Directory of Open Access Journals (Sweden)

    Joshua M Owen

    2016-01-01

    Full Text Available Objectives: The objective of this study was to evaluate the concordance between clinical symptoms, Doppler ultrasound (US, and shunt venography for the detection of stent-graft transjugular intrahepatic portosystemic shunt (TIPS dysfunction. Materials and Methods: Forty-one patients (M:F 30:11, median age 55 years who underwent contemporaneous clinical exam, Doppler US, and TIPS venography between 2003 and 2014 were retrospectively studied. Clinical symptoms (recurrent ascites or variceal bleeding were dichotomously classified as present/absent, and US and TIPS venograms were categorized in a binary fashion as normal/abnormal. US abnormalities included high/low (>190 or 50 cm/s, absent flow, and return of antegrade intra-hepatic portal flow. Venographic abnormalities included shunt stenosis/occlusion and/or pressure gradient elevation. Clinical and imaging concordance rates were calculated. Results: Fifty-two corresponding US examinations and venograms were assessed. The median time between studies was 3 days. Forty of 52 (77% patients were symptomatic, 33/52 (64% US examinations were abnormal, and 20/52 (38% TIPS venograms were abnormal. Concordance between clinical symptoms and TIPS venography was 48% (25/52, while the agreement between US and shunt venography was 65% (34/52. Clinical symptoms and the US concurred in 60% (31/52 of the patients. The sensitivity of clinical symptoms and US for the detection of venographically abnormal shunts was 80% (16/20 and 85% (17/20, respectively. Both clinical symptoms and the US had low specificity (25%, 8/32 and 50%, 16/32 for venographically abnormal shunts. Conclusion: Clinical findings and the US had low concordance rates with TIPS venography, with acceptable sensitivity but poor specificity. These findings suggest the need for improved noninvasive imaging methods for stent-graft TIPS surveillance.

  14. Diagnostic significance of hepatic venography and retrograde portography in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Fukunaga, Masaki

    1987-07-01

    In this series, we studied about diagnostic significance of hepatic venography and retrograde portography in portal hypertension by using stepwise discriminant analysis. The accuracy rate of the discrimination was 95 % in liver cirrhosis (LC), 86 % in B' type LC, 83 % in primary biliary cirrhosis (PBC) and 57 % in idiopathic portal hypertension (IPH). The difficulty in differential diagnosis of IPH from PBC was due to similarity of hepatic vascular changes in both diseases. Next we studied about the relationship between venographic findings and the causes of LC. The size of regenerated nodule in alcoholic LC was significantly smaller than the others, so venographic findings were different from others. It was concluded that hepatic venography was useful examination for differential diagnosis in portal hypertension, and was effective for considering about the causes of LC.

  15. Diagnostic significance of hepatic venography and retrograde portography in portal hypertension

    International Nuclear Information System (INIS)

    Fukunaga, Masaki

    1987-01-01

    In this series, we studied about diagnostic significance of hepatic venography and retrograde portography in portal hypertension by using stepwise discriminant analysis. The accuracy rate of the discrimination was 95 % in liver cirrhosis (LC), 86 % in B' type LC, 83 % in primary biliary cirrhosis (PBC) and 57 % in idiopathic portal hypertension (IPH). The difficulty in differential diagnosis of IPH from PBC was due to similarity of hepatic vascular changes in both diseases. Next we studied about the relationship between venographic findings and the causes of LC. The size of regenerated nodule in alcoholic LC was significantly smaller than the others, so venographic findings were different from others. It was concluded that hepatic venography was useful examination for differential diagnosis in portal hypertension, and was effective for considering about the causes of LC. (author)

  16. Widening of mediastinum with persistent left superior Vena cava - CT diagnosis

    International Nuclear Information System (INIS)

    Neuwirth, J.; Kolar, J.

    1992-01-01

    Described in this paper are radiographic findings recorded from a case of persistent left superior vena cava which grew manifest by widening of the left contour of the upper mediastinal region. Contrast-enhanced computed tomography (CT) was undertaken to clear up suspicion of mediastinal tumour and revealed double superior vena cava. The diagnosis was then confirmed by digital subtraction venography. (orig.) [de

  17. Hepatic venography in noncirrhotic idiopathic portal hypertension: comparison with cirrhosis of the liver

    International Nuclear Information System (INIS)

    Futagawa, S.; Fukazawa, M.; Musha, H.

    1981-01-01

    Free and wedged hepatic venography were carried out in 37 patients with idiopathic portal hypertension (IPH) and the findings compared with those in 88 patients with cirrhosis of the liver. Characteristic changes in IPH included frequent vein-to-vein anastomoses, narrower angles between large veins and their tributaries, smooth and wavy middle-sized to large branches (giving a general ''weeping willow'' appearance), homogeneous sinusoidal filling, and minimal to absent filling of the portal venous system on wedged retrograde portography. In cirrhosis, by contrast, changes included rare vein-to-vein anastomoses, wide angles between veins and tributaries, irregular stenoses of large veins and branches at various levels, spotty sinusoidal filling, and frequent retrograde flow in the portal venous system. Hepatic venography is helpful in differentiating IPH from cirrhosis

  18. 3D gadolinium-enhanced MRI venography: Evaluation of central chest veins and impact on patient management

    International Nuclear Information System (INIS)

    Oxtoby, J.W.; Widjaja, E.; Gibson, K.M.; Uzoka, K.

    2001-01-01

    AIM: To assess the value of a simplified 3D gadolinium-enhanced magnetic resonance imaging (MRI) venography for central chest veins. MATERIALS AND METHODS: In this retrospective study of 24 patients, the MRI findings and medical records were reviewed to determine whether MRI results correlated with subsequent findings, and to determine the effect on clinical management. 3D steady state gradient-echo sequence, fast imaging with steady state precession (FISP), was used. We employed a simplified protocol not requiring bolus timing or subtraction to achieve rapid data acquisition and hence good compliance in this group of frail patients. Following intravenous administration of a bolus of gadolinium, two acquisitions were obtained in order to ensure adequate opacification of all veins. Individual partitions and maximum intensity projections were then analysed to determine whether the veins were patent, stenosed or occluded. RESULTS: The indications for MRI were to assess the patency of central veins for the purpose of cannulation or arteriovenous fistula formation in 17 patients. Out of the 12 patients who proceeded to an intervention, MRI venography successfully predicted an appropriate site in 10 patients. In the remaining seven patients, MRI venography was valuable in confirming or excluding the clinical suspicion of central venous thrombosis and directly influenced the management in five patients. CONCLUSION: 3D gadolinium-enhanced MRI venography is a valuable means of providing a global representation of the central venous system and guiding subsequent central venous cannulation. Oxtoby, J.W. et al. (2001)

  19. Fine-needle percutaneous transhepatic parenchymal portal venography by using carbon dioxide: a pilot study in pigs

    International Nuclear Information System (INIS)

    Sun, Fei; Hernandez, Javier; Crisostomo, Veronica; Pineda, Luis-Fernando; Lima, Juan Rafael; Uson, Jesus; Maynar, Manuel

    2003-01-01

    Our purpose was to evaluate the feasibility and safety of carbon dioxide (CO 2 ) in fine-needle percutaneous transhepatic parenchymal portal venography and its potential clinical applications. Three Belgian landrace pigs received fine-needle percutaneous transhepatic parenchymal portal venography by using CO 2 as a contrast agent. Under fluoroscopic and B-mode ultrasonic guidance, right or left lobe of liver was punctured with a 22-G Chiba needle, through which CO 2 was injected with a dedicated CO 2 injector at injection rate of 20 ml/s for 20 ml, 40 ml/s for 40 ml, 40 ml/s for 60 ml, and 40 ml/s for 80 ml, respectively. The portal venograms were obtained by use of digital subtraction angiography (DSA) system with animal in supine position. In one pig transarterial portal venography was performed, in addition, using iodinated contrast agent. The portal vein was visualized in each run of venography. Optimal images of portal tree structure up to four-order branches were obtained in all those with CO 2 injection rate of 40 ml/s, which appeared much better in quality than those obtained by cranial mesenteric arteriography with iodinated contrast agent. No extravasation of CO 2 , liver laceration, or any other complication occurred during the procedures. The technique we proposed demonstrated optimal portography, which appeared to be safe, minimally invasive, less time-consuming, cost-effective, and easy to perform, with great potential in clinical applications. (orig.)

  20. Compression of the posterior fossa venous sinuses by epidural hemorrhage simulating venous sinus thrombosis: CT and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Sumit; Ramakrishnaiah, Raghu H.; Hegde, Shilpa V.; Glasier, Charles M. [University of Arkansas for Medical Sciences, Pediatric Radiology, Little Rock, AR (United States)

    2016-01-15

    Posterior fossa dural venous sinus thrombus is a well-described complication of head trauma, especially when fracture crosses the dural sinus grooves or in association with epidural hemorrhage. We have found that post-traumatic posterior fossa epidural hematoma compressing a dural venous sinus can mimic dural venous thrombus. To discuss the CT and MRI findings of posterior fossa epidural hemorrhages simulating sinus thrombosis, to make radiologists aware of this important imaging pitfall. We describe radiologic findings in four children in whom a posterior fossa epidural hemorrhage mimicked dural venous sinus thrombus. Routine CT head and CT venography were obtained on Toshiba volume and helical CT scanners. MRI and MR venography were performed on a Philips scanner. In all cases there was medial displacement and compression of the posterior fossa dural venous sinuses without intraluminal thrombosis. The epidural hemorrhage was seen tracking along sinus grooves in the occipital bone, peeling the dura containing the sinuses from the calvarium and compressing the sinus, simulating thrombosis on axial CT views. Both venous sinus thrombosis and posterior fossa epidural hemorrhages in children are well-described complications of head trauma. Posterior fossa epidural hemorrhage can mimic a sinus thrombus by compressing and displacing the sinuses. It is important to recognize this pitfall because treatment of a suspected thrombus with anticoagulation can worsen epidural hemorrhage. (orig.)

  1. Compression of the posterior fossa venous sinuses by epidural hemorrhage simulating venous sinus thrombosis: CT and MR findings

    International Nuclear Information System (INIS)

    Singh, Sumit; Ramakrishnaiah, Raghu H.; Hegde, Shilpa V.; Glasier, Charles M.

    2016-01-01

    Posterior fossa dural venous sinus thrombus is a well-described complication of head trauma, especially when fracture crosses the dural sinus grooves or in association with epidural hemorrhage. We have found that post-traumatic posterior fossa epidural hematoma compressing a dural venous sinus can mimic dural venous thrombus. To discuss the CT and MRI findings of posterior fossa epidural hemorrhages simulating sinus thrombosis, to make radiologists aware of this important imaging pitfall. We describe radiologic findings in four children in whom a posterior fossa epidural hemorrhage mimicked dural venous sinus thrombus. Routine CT head and CT venography were obtained on Toshiba volume and helical CT scanners. MRI and MR venography were performed on a Philips scanner. In all cases there was medial displacement and compression of the posterior fossa dural venous sinuses without intraluminal thrombosis. The epidural hemorrhage was seen tracking along sinus grooves in the occipital bone, peeling the dura containing the sinuses from the calvarium and compressing the sinus, simulating thrombosis on axial CT views. Both venous sinus thrombosis and posterior fossa epidural hemorrhages in children are well-described complications of head trauma. Posterior fossa epidural hemorrhage can mimic a sinus thrombus by compressing and displacing the sinuses. It is important to recognize this pitfall because treatment of a suspected thrombus with anticoagulation can worsen epidural hemorrhage. (orig.)

  2. Atrophic inferior vena cava is a marker of chronicity of intra-filter and inferior vena cava thrombosis: based on CT findings.

    Science.gov (United States)

    Chen, Liang; Shi, Wanyin; Gu, Jianping; He, Xu; Lou, Wensheng

    2018-04-11

    A permanently indwelling filter in the inferior vena cava (IVC) may induce caval thrombosis, which could develop and evolve from an acute to a chronic phase. The differential diagnosis of acute and chronic thromboses determines the treatment strategy. The role of computed tomography (CT) in diagnosing acute and chronic intra-filter and IVC thromboses has not been well established. This retrospective study summarizes the CT signs that indicate acute and chronic phases of intra-filter and IVC thromboses. This study included eight patients who developed a lower-extremity deep venous thrombosis (DVT) and were treated with intracaval filter placement as an alternative to anticoagulation and thrombolysis. During the follow-up, all patients developed an intra-filter thrombosis in the IVC confirmed by CT and/or CT venography (CTV). Demographic and CT data of all patients during the follow-up period were collected for analysis. All patients had normal-appearing IVCs prior to filter placement, as shown on trans-femoral venography. Eight filters (five TrapEase, three OptEase) were placed in the eight IVCs, respectively. Subsequently, IVC-CT or CTV revealed acute intra-filter or IVC thrombosis in all eight patients, manifesting as an intracaval filling defect and thickened IVC wall. Filter protrusion and secondary caval atrophy seen on CT indicated a chronically occluded IVC. IVC thrombosis may result from filter placement. The chronicity of caval thrombotic occlusion is likely to be associated with filter protrusion and secondary IVC atrophy revealed on CT scans.

  3. Rapid MR venography in children using a blood pool contrast agent and multi-station fat-water-separated volumetric imaging

    International Nuclear Information System (INIS)

    Ghanouni, Pejman; Walters, Shannon G.; Vasanawala, Shreyas S.

    2012-01-01

    A rapid, reliable radiation-free method of pediatric body venography might complement US by evaluating veins in the abdomen and pelvis and by providing a global depiction of venous anatomy. We describe a MR venography technique utilizing gadofosveset, a blood pool contrast agent, in children. The technique allows high-spatial-resolution imaging of the veins from the diaphragm to the knees in less than 15 min of total exam time. (orig.)

  4. Radionuclide venography of lower limbs by subcutaneous injection

    International Nuclear Information System (INIS)

    Wu, Chung-Chieng; Jong, Shiang-Bin

    1989-01-01

    We have proved that subcutaneous injection (SC) of a small dose of Tc-99m pertechnetate (1 to 2 mCi: 37 to 74 MBq) at acupuncture points (K-3 and B-60) may offer an alternative method of radionuclide venography (RNV) of the lower limbs. In this study, we compared intravenous (IV) RNV and SC-RNV in 22 consecutive cases with typical signs and symptoms suggesting venous abnormality of the lower limb(s) from March to May 1988. They are 11 male and 11 female, aged 47.7±15.7 years. Among the 44 limbs of the 22 cases, 4 were normal, 12 (27.3%) were found to have varicose veins in the legs only, 18 (40.9%) had partial stenosis of the deep veins (14 poplito-tibial and 4 superficial femoral), and 13 (29.6%) had complete stenosis of the deep veins (4 poplito-tibial, 1 superficial femoral and 8 ilio-femoral. SC-RNV showed almost the same results as IV-RNV in 21 (47.7%), superior to IV-RNV in 22 (50%) (including 4.6% failure of IV-RNV), and inferior to IV-RNV in 1 (2.3%). We conclude that SC-RNV is definitely an alternative method of lower-limb venography. Since it is in most cases superior to IV-RNV, we suggest that it can take the place of IV-RNV in routine work. (author) 62 refs

  5. Sixteen-row multislice computed tomography in the assessment of pulmonary veins prior to ablative treatment: validation vs conventional pulmonary venography and study of reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Maksimovic, R.; Cademartiri, F.; Pattynama, P.M.T. [Erasmus Medical Center, Rotterdam (Netherlands). Dept. of Radiology; Scholten, M; Jordaens, L.J. [Erasmus Medical Center, Rotterdam (Netherlands). Dept. of Cardiology

    2004-03-01

    The aim of this study was to validate multislice computed tomography (MSCT) venography measurements of pulmonary vein (PV) diameters vs conventional pulmonary venography (CPV), and to assess the reproducibility of MSCT data. The study included 21 consecutive patients with atrial fibrillation who were planned for cryothermal ablation of PVs. One day before ablation, all patients underwent CPV and contrast-enhanced non-gated MSCT venography. The MSCT was repeated 3 months after ablation. The CPV images of the treated PVs (n=40) were analyzed and compared with the results of MSCT measurements. Reproducibility of MSCT venography-based data was assessed by interobserver (n=84 PVs) and interexamination (n=44 PVs) variability. Pre-treatment PV diameters on MSCT and CPV showed good correlation (r=0.87, p<0.01; 18.9{+-}2.3 mm, 188.5{+-}2.4 mm, respectively). Interobserver agreement and interexamination reproducibility were good (r=0.91, r=0.82, respectively, p<0.01), with narrow limits of agreement (Bland and Altman method). The MSCT venography allows accurate and reproducible assessment of PVs. It can be used both in non-invasive planning of treatment for ablative therapy and in the follow-up of patients.

  6. Comparison of sonography and venography in the diagnosis of lower extremity deep venous thrombosis

    International Nuclear Information System (INIS)

    Mostbeck, G.H.; Kettenbach, J.; Henk, C.

    1993-01-01

    In recent years, non-invasive sonographic techniques [real-time ultrasound (US), duplex ultrasonography (DU) and color-coded duplex sonography (CCDS)] have increased in importance for the diagnosis of lower extremity deep venous thrombosis. To ascertain the accuracy and limitations of these techniques prospectively, various studies have been performed to compare sonography with venography. This review deals with basic methodologic considerations when two imaging methds are compared and describes the features of deep venous thrombosis seen on US, DU and CCDS. Reports comparing sonography and phlebography for the diagnosis of deep venous thrombosis are presented and discussed. The advantages and limitations of US, DU and CCDS for the diagnosis of iliac, femoral, popliteal and infrapopliteal venous thrombosis are compared with those of venography, and controversial areas are touched on. (orig.) [de

  7. Vertebral uptake of Tc-99m macroaggregated albumin (MAA) with SPECT/CT occurring in superior vena cava obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Karls, Shawn; Hassoun, Hani; Derbekyan, Vilma [Dept. of Nuclear Madicine, Royal Victoria Hospital, Montreal (Canada)

    2016-09-15

    A 67-year-old male presented with dyspnea for which lung scintigraphy was ordered to rule out pulmonary embolus. Planar images demonstrated abnormal midline uptake of Tc-99m macroaggregated albumin, which SPECT/CT localized to several thoracic vertebrae. Thoracic vertebral uptake on perfusion lung scintigraphy was previously described on planar imaging. Radionuclide venography and contrast-enhanced CT subsequently demonstrated superior vena cava (SVC) obstruction with collateralization through the azygous/hemiazygous system and vertebral venous plexus. SPECT/CT differentiated residual esophageal/tracheal ventilation activity, a clinically insignificant finding, from vertebral uptake indicative of SVC obstruction, a potentially life-threatening condition.

  8. Analysis of hepatic vein variations in healthy people with 64-slice spiral CT

    International Nuclear Information System (INIS)

    Zhang Rong; Li Yong; Shen Jun; Zeng Weike; Li Jieting; Huang Suiqiao; Liang Biling; Liu Chao

    2007-01-01

    Objective: To analyze variations of hepatic vein in healthy people with 64-slice spiral CT. Methods: Seventy-five healthy subjects underwent multi-slice spiral computed (MSCT) hepatic venography. The anatomy of the junction of the hepatic veins with the inferior vena cava and the intrahepatic drainage territory of the hepatic veins and tributaries were evaluated. The hepatic veins were classified according to three anatomic classification (Nakamura's, Marcos's and Kawasaki's classification) methods respectively. Results: There was a common trunk of the middle and left hepatic veins before joining the IVC in 86.7% (65/75)of the cases. In 13.3% (10/75)of the cases, the three main hepatic veins joined the IVC separately. The ratios of Nakamma's classification type A, B, C of hepatic veins were 49.4% (37/75), 37.3% (28/75), and 13.3% (10/75) respectively. The ratios of Marcos's classification type A, B, C of hepatic veins were 56.0% (42/75), 24.0% (18/75), and 20.0% (15/75) respectively. The ratios of Kawasaki's classification type I, II of hepatic vein were 40.0% (30/75) and 60.0% (45/75). Conclusion: Multi-slice spiral CT hepatic venography can provide visualization of peripheral hepatic venous branches in details. (authors)

  9. An ovine model of cerebral catheter venography for implantation of an endovascular neural interface.

    Science.gov (United States)

    Oxley, Thomas James; Opie, Nicholas Lachlan; Rind, Gil Simon; Liyanage, Kishan; John, Sam Emmanuel; Ronayne, Stephen; McDonald, Alan James; Dornom, Anthony; Lovell, Timothy John Haynes; Mitchell, Peter John; Bennett, Iwan; Bauquier, Sebastien; Warne, Leon Norris; Steward, Chris; Grayden, David Bruce; Desmond, Patricia; Davis, Stephen M; O'Brien, Terence John; May, Clive N

    2018-04-01

    OBJECTIVE Neural interface technology may enable the development of novel therapies to treat neurological conditions, including motor prostheses for spinal cord injury. Intracranial neural interfaces currently require a craniotomy to achieve implantation and may result in chronic tissue inflammation. Novel approaches are required that achieve less invasive implantation methods while maintaining high spatial resolution. An endovascular stent electrode array avoids direct brain trauma and is able to record electrocorticography in local cortical tissue from within the venous vasculature. The motor area in sheep runs in a parasagittal plane immediately adjacent to the superior sagittal sinus (SSS). The authors aimed to develop a sheep model of cerebral venography that would enable validation of an endovascular neural interface. METHODS Cerebral catheter venography was performed in 39 consecutive sheep. Contrast-enhanced MRI of the brain was performed on 13 animals. Multiple telescoping coaxial catheter systems were assessed to determine the largest wide-bore delivery catheter that could be delivered into the anterior SSS. Measurements of SSS diameter and distance from the motor area were taken. The location of the motor area was determined in relation to lateral and superior projections of digital subtraction venography images and confirmed on MRI. RESULTS The venous pathway from the common jugular vein (7.4 mm) to the anterior SSS (1.2 mm) was technically challenging to selectively catheterize. The SSS coursed immediately adjacent to the motor cortex (SSS. Attempted access with 5-Fr and 6-Fr delivery catheters was associated with longer procedure times and higher complication rates. A 4-Fr catheter (internal lumen diameter 1.1 mm) was successful in accessing the SSS in 100% of cases with no associated complications. Complications included procedure-related venous dissection in two major areas: the torcular herophili, and the anterior formation of the SSS. The

  10. CT imaging of hepatic veno-occlusive disease (an analysis 14 cases)

    International Nuclear Information System (INIS)

    Zhang Guohua; Kong Azhao; Fang Junwei; Chen Yuejing; Zheng Weiliang; Dong Danjun; Zhang Shizheng

    2006-01-01

    Objective: To probe imaging characteristics of the hepatic veno-occlusive disease (VOD) based on clinical features and abdomen CT findings. Methods: Fourteen patients including 6 male and 8 female aged from 41 to 73 years were enrolled in this study. They all had previous trauma history and notoginseng was given as herbal remedy. Dynamic enhanced CT and color Dopplor ultrasound examinations were routinely used. Two of them received venous angiography and four cases were pathologically proved as VOD after CT guided needle biopsy. Results: Hepatic swelling and ascites were found on plain CT scan. Diffuse patchy areas without enhancement indicative of poorly hepatic perfusion were found. Hepatic veins were compressed and became thin, and inferior vena cava was flat and narrow without distal dilation or collateral circulation. No obstruction of hepatic veins and inferior vena cava was found on ultrasound and venography. Conclusion: Dynamic enhanced CT is highly valuable for early assessing VOD and imaging features of venous hepatic congestion found on CT was strongly suggestive of VOD if there's previous history of treatment of gynura segetum. (authors)

  11. Adopting wedge hepatic venography with CO2 during transjugular intrahepatic portosystemic shunt procedures

    International Nuclear Information System (INIS)

    Zhang Linpeng; Chen Songtao; Shi Xiulan

    2012-01-01

    Objective: To renovate angiography in identifying portal vein anatomy during transjugular intrahepatic portosystemic shunt (TIPS) procedures, saving the time of TIPS procedures, decreasing the risk of the complications of the post-procedure. Methods: The difference between the Wedge hepatic venography with Carbon Dioxide in 6 cases and Inferior Mesenteric artery angiography in 7 cases during TIPS procedures were compared in the identification of portal vein anatomy. The quality of images, their effects on the procedures, the complications and the recovery post-procedure were evaluated. Results: Using CO 2 , the portal veins were opacified in all 6 cases. TIPS procedures succeeded in all cases except 1 case because of poor coagulation function. Using Inferior Mesenteric artery angiography, the portal veins were opacified in all 7 cases. TIPS procedure succeeded in all cases except 1 case because of chronic portal occlusion. Puncture-site hematoma occurred in 1 case after TIPS procedure. Conclusion: Wedge hepatic venography with Carbon Dioxide is superior, safer and more convenient than Inferior Mesenteric Artery angiography in identifying portal vein anatomy during TIPS. (authors)

  12. Experimental study on venography with carbon dioxide by fine-needle direct-puncture of abdominal viscera

    International Nuclear Information System (INIS)

    Zhu Chi; Xu Changliang; Zhang Dezhi; Zheng Feiqun; Sheng Qiang; Zhang Xiuze; Xiong Zhuang; Yu Yongqiang

    2005-01-01

    Objective: To evaluate the feasibility and safety of CO 2 venography by fine-needle direct-puncture of abdominal viscera. Methods: Two healthy female pigs and two healthy female dogs were used in this study. Multi-point punctures of abdominal viscera including liver, spleen, kidney, pancreas, walls of small intestines, and uterus with 25-gauge needle were performed for CO 2 venography in all animals. Diagnostic image quality of the angiographic images was assessed by 3 independent observers. Results: Splenic-portal vein, hepatic vein, portal vein, renal vein and inferior vena cava, uterine vein and ovarian vein could be visualized by fine needle direct CO 2 injection into the related organic parenchyma, while draining vein of small intestines and pancreas could not be shown. Splenic-portal veins were revealed especially well with grade A of 87.5% (7/8) , grade B of 12.5% (1/8), and grade C of 0%. The image quality of hepatic veins were 81.8% (9/11), 18.2% (2/11), and 0% for grade A, B, and C, respectively. The portal veins were 77.8% (7/9), 22.2%(2/9), and 0% for grade A, B, and C, respectively. The renal vein and inferior vena cava were 38.5% (5/13), 61.5% (8/13), and 0% for grade A, B, and C respectively. The uterine veins and ovarian veins were 0%, 33.3% (2/6), and 66.7% (4/6) for grade A, B, and C, respectively. During the CO 2 angiographic procedure, vital signs remained stable in all animals. Conclusion: CO 2 venography with fine-needle direct-puncture of abdominal viscera, excluding small intestines and pancreas, is feasible and safe. (authors)

  13. Pattern of magnetic resonance imaging and magnetic resonance venography changes in cerebral venous sinus thrombosis

    International Nuclear Information System (INIS)

    Zafar, A.; Ali, Z.

    2012-01-01

    Background: Cerebral venous sinus thrombosis is a common but highly under-recognised condition, which is missed not only by general practitioners but also by neurologists. Computerised tomography (CT) or magnetic resonance imaging (MRI) of brain alone is not sufficient to diagnose this condition. Objective of this study was to explore the pattern of magnetic resonance imaging (MRI) and magnetic resonance venography (MRV) changes in cerebral venous sinus thrombosis (CVST). Methods: This was a descriptive study in which 52 cases of cerebral venous sinus thrombosis with special emphasis on their MRI and MRV findings were included. The study was conducted in Neurology Unit, Lady Reading Hospital, Peshawar, Pakistan, from January 2010 to July 2011. All patients suffering from cerebral venous sinus thrombosis were included in the study. Multi-planar/multi-sequential, Tesla 1.5 MRI/MRV time of flight images were done in all cases where there was suspicion of cerebral venous sinus thrombosis. Results: Out of 52 patients with cerebral venous sinus thrombosis 41 (78.84%) were female and 11 (21.15%) were male. Mean age was 37+-5 years. Definite risk factors were found in 38 (73.076%) patients with pregnancy, use of oral contraceptives or puerperium being the most frequently found risk factor in 20 (73.076%) patients. Most common complaint was headache found in 41 (78.84%) patients, followed by focal neurological deficits, and altered mental status and seizures. Papilloedema was seen in 20 (38.46%) patients. The cerebral venous sinuses most frequently involved were transverse and sigmoid sinuses in 17 patients (32.69%) while superior sagittal sinus alone in 10 (19.23%) patients. Overall CT brain was normal in 30% and MRI brain in 23.07% patients; however, MRV of these patients revealed CVST. Conclusion: Imaging plays a primary role in the diagnosis of cerebral venous sinus thrombosis because the clinical picture of CVST is non-specific and highly variable. Thrombosis of

  14. Jugular bulb diverticulum combined with high jugular bulb: a case report with CT and MRA findings

    International Nuclear Information System (INIS)

    Ko, Seog Wan

    2004-01-01

    Jugular bulb diverticulum is a rare condition that is characterized by the outpouching of the jugular bulb, and this can lead to hearing loss, tinnitus and vertigo. A few reports have revealed the radiologic findings about jugular bulb diverticulum, but none of them have described the MRA findings concerning this lesion. We present here the CT and MR venography findings in regards to a large high jugular blub and diverticulum we observed in a 47-year-old woman

  15. Jugular bulb diverticulum combined with high jugular bulb: a case report with CT and MRA findings

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Seog Wan [College of Medicine, Chonbuk National Univ., Jeonju (Korea, Republic of)

    2004-12-01

    Jugular bulb diverticulum is a rare condition that is characterized by the outpouching of the jugular bulb, and this can lead to hearing loss, tinnitus and vertigo. A few reports have revealed the radiologic findings about jugular bulb diverticulum, but none of them have described the MRA findings concerning this lesion. We present here the CT and MR venography findings in regards to a large high jugular blub and diverticulum we observed in a 47-year-old woman.

  16. The technique advantages of 16-detector multic-slice spiral CT in evaluating combined pulmonary and deep vein thromboembolism

    International Nuclear Information System (INIS)

    Xia Shuang; Qi Ji; Lei Xinwei; Wen Lianqing; Li Yiming; Liu Jisheng

    2004-01-01

    Objective: To study the scanning technique of 16-detector multic-slice spiral CT(MSCT) for combined pulmonary artery and deep vein of lower limb in pulmonary thromboembolism (PE) patients. Methods: Forty suspected pulmonary thromboembolism patients were performed both pulmonary artery angiography (CTA) and indirect deep vein venography (CTV) on 16-detector MSCT. The parameters of the latter as following: total contrast volume 120-150 ml, injection rate 4.0-4.5 ml/s (from antecubital vein), delay time 4.0 for CTA 20-23 s, CTV 120-180 s, collimation for CTA 1.25 mm and 0.625 mm, CTV 2.5 mm, scan range of CTV: from popliteal vein to the level of bilateral renal vein into the inferior vena cava. Postprocessing include MPR, MIP, and VR. The test was used to analyzed the images. Results: Twenty five patients had both pulmonary thromboembolism (PE) and deep vein thromboembolism (DVT), 8 patients had only DVT, 2 had only PE, and 5 had neither. There was no difference between different collimation in depicting thrombus. The CT value number of enhanced pulmonary artery and lower deep vein was obviously higher than the thrombus. The value of MPR, MIP, VR for PE was 100%, 100%, and 65%, The value of MPR, MIP, VR for DVT is 100%, 60%, and 50%. Conclusion: The technique of combined pulmonary CTA and deep vein CTV of 16-detector MSCT will provide a new modality for pulmonary thromboembolism patients. (author)

  17. Selective testicular venography for the localization of undescended testicles

    International Nuclear Information System (INIS)

    Vlahos, L.; Haliasos, N.; Pantazopoulos, C.; Pontifex, G.; King Paul's Hospital, Athens

    1980-01-01

    Percutaneous venography of the internal spermatic vein was performed for the localization of unpalpable testicles in 5 patients varying from 4 to 45 years of age. The catheterization of the vein on the left side was successful in all 5 cases; and the testicle was localized and verified by surgery in all but one case in which a competent valve prevented the retrograde filling of the whole length of the vein down to the testicle. In the two patients with bilateral undescended testicles the right internal vein could not be identified in one patient, and in the other patient a semiselective injection was done into that vein which appeared to represent the spermatic vein, but the examination was not conclusive. (orig.) [de

  18. Selective testicular venography for the localization of undescended testicles

    Energy Technology Data Exchange (ETDEWEB)

    Vlahos, L.; Haliasos, N.; Pantazopoulos, C.; Pontifex, G.

    1980-04-01

    Percutaneous venography of the internal spermatic vein was performed for the localization of unpalpable testicles in 5 patients varying from 4 to 45 years of age. The catheterization of the vein on the left side was successful in all 5 cases; and the testicle was localized and verified by surgery in all but one case in which a competent valve prevented the retrograde filling of the whole length of the vein down to the testicle. In the two patients with bilateral undescended testicles the right internal vein could not be identified in one patient, and in the other patient a semiselective injection was done into that vein which appeared to represent the spermatic vein, but the examination was not conclusive.

  19. Contrast venography of the leg: diagnostic efficacy, tolerance, and complication rates with ionic and nonionic contrast media

    International Nuclear Information System (INIS)

    Bettmann, M.A.; Robbins, A.; Braun, S.D.; Wetzner, S.; Dunnick, N.R.; Finkelstein, J.

    1987-01-01

    A prospective, three-center study of two contrast agents for leg venography was performed to evaluate both the relative frequency of adverse effects and whether low-osmolality agents provided significant advantages for this procedure. Fifty-four patients were studied with the standard preparation (iothalamate meglumine) and 57 with a nonionic agent (iopamidol). Both were used at an iodine concentration of 200 mg/mL, and there were no differences in volume of contrast material, duration of infusion, percentage of positive studies, or overall diagnostic adequacy. Patient discomfort was less with iopamidol than with iothalamate (18% vs. 44%), although discomfort was generally mild in both groups. By objective follow-up studies, the frequency of postvenographic thrombosis was not significantly different in the two groups (8% vs. 9%). Contrast venography, then, had a low frequency of complications when either a dilute conventional or a low-osmolality agent was employed. Although the frequency of postvenographic thrombosis was low with both agents, patient discomfort was less with the low-osmolality formulation

  20. Infarction and Laceration of Liver Parenchyma Caused by Wedged CO2 Venography Before TIPS Insertion

    International Nuclear Information System (INIS)

    Theuerkauf, Ingo; Strunk, Holger; Brensing, Karl August; Schild, Hans Heinz; Pfeifer, Ulrich

    2001-01-01

    We describe the fatal outcome of an elective TIPS procedure performed in a 43-year-old man with alcoholic cirrhosis. Wedged hepatic venography with CO 2 was the reason for infarction and laceration of liver parenchyma resulting in a subcapsular hematoma and subsequent intra-abdominal bleeding. This is the first report of this complication after the use of CO 2 in a cirrhotic patient

  1. Contrast-enhanced MR venography of the head using magnetization prepared rapid gradient echo imaging. Comparison between head and body radiofrequency transmitter coil systems

    International Nuclear Information System (INIS)

    Matsunobu, Satosi; Amanuma, Makoto; Tsukuda, Shunji

    2004-01-01

    The purpose of this study was to evaluate the image quality and vascular selectivity of MR venography of the head using an magnetization prepared rapid gradient echo (MP-RAGE) technique when obtained with a body radiofrequency transmitter coil system. A total of 24 patients were imaged with a head or body radiofrequency (RF) transmission system. Subtraction MR angiography (MRA) was processed with 0.1 mmol Gd-DTPA administration, and signal-to-noise ratios of the vascular system were measured. Venous demonstration and selectivity were also assessed. MP-RAGE MR venography with a body transmission system showed almost the same signal intensity for the venous and arterial systems, resulting in nonspecific vascular demonstration, while the head transmission system showed semi-selective venograms owing to inflow-induced high signal on precontrast images. However, MRA with a body transmission system provided a 1.5- to 2.5-fold higher signal-to-noise ratios based on higher gradient performance and excellent demonstration of the head veins, especially those below the skull base. Although selective venography was difficult, MRA with a body transmission coil provided excellent vascular images of the brain. (author)

  2. Mineralocorticoid hypertension: clinical and laboratory studies with special reference to selective percutaneous venography combined with aldosterone assay in the adrenal venous blood

    International Nuclear Information System (INIS)

    Wajchenberg, B.L.; Liberman, B.; Novaes, M.

    1977-01-01

    With the purpose of demonstrating the presence of hypertension, hypokalemia and alkalosis were studied. The presence of daily aldosteronism was verified in five patients; the sixth one presented no daily aldosteronism but an increase of 18-OH-DOCA production, an ACTH dependente mineralocorticoid. The presence of tumor (less than 0.9cm) could not be shown in two patients by bilateral selective adrenal venography. The aldosterone assay during catherization of adrenal vein of those patients permitted to determine the tumoral side. Attention must be given to the fact that the blood collection of adrenal vein must always be made during adrenal venography to demonstrate the presence of short unilateral tumor or bilateral disease [pt

  3. Infarction and Laceration of Liver Parenchyma Caused by Wedged CO{sub 2} Venography Before TIPS Insertion

    Energy Technology Data Exchange (ETDEWEB)

    Theuerkauf, Ingo [Department of Pathology, University of Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Strunk, Holger [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Brensing, Karl August [Department of Internal Medicine, University of Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Schild, Hans Heinz [Department of Radiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Pfeifer, Ulrich [Department of Pathology, University of Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany)

    2001-01-15

    We describe the fatal outcome of an elective TIPS procedure performed in a 43-year-old man with alcoholic cirrhosis. Wedged hepatic venography with CO{sub 2} was the reason for infarction and laceration of liver parenchyma resulting in a subcapsular hematoma and subsequent intra-abdominal bleeding. This is the first report of this complication after the use of CO{sub 2} in a cirrhotic patient.

  4. Dual compression is not an uncommon type of iliac vein compression syndrome.

    Science.gov (United States)

    Shi, Wan-Yin; Gu, Jian-Ping; Liu, Chang-Jian; Lou, Wen-Sheng; He, Xu

    2017-09-01

    Typical iliac vein compression syndrome (IVCS) is characterized by compression of left common iliac vein (LCIV) by the overlying right common iliac artery (RCIA). We described an underestimated type of IVCS with dual compression by right and left common iliac arteries (LCIA) simultaneously. Thirty-one patients with IVCS were retrospectively included. All patients received trans-catheter venography and computed tomography (CT) examinations for diagnosing and evaluating IVCS. Late venography and reconstructed CT were used for evaluating the anatomical relationship among LCIV, RCIA and LCIA. Imaging manifestations as well as demographic data were collected and evaluated by two experienced radiologists. Sole and dual compression were found in 32.3% (n = 10) and 67.7% (n = 21) of 31 patients respectively. No statistical differences existed between them in terms of age, gender, LCIV diameter at the maximum compression point, pressure gradient across stenosis, and the percentage of compression level. On CT and venography, sole compression was commonly presented with a longitudinal compression at the orifice of LCIV while dual compression was usually presented as two types: one had a lengthy stenosis along the upper side of LCIV and the other was manifested by a longitudinal compression near to the orifice of external iliac vein. The presence of dual compression seemed significantly correlated with the tortuous LCIA (p = 0.006). Left common iliac vein can be presented by dual compression. This type of compression has typical manifestations on late venography and CT.

  5. Anomalies of the vena cava inferior

    International Nuclear Information System (INIS)

    Koen, F.R.; Bouwer, A.J.; Bornman, M.S.; Du Plessis, D.J.

    1986-01-01

    Two cases of anomalous inferior vena cava are presented, with the emphasis on embryology. The firts patient was investigated by venography for a clinically proven varicocele as a probable cause of infertility. A double inferior vena cava was found during venography, and was confirmed by computed tomography (CT). In the second case a left-sided inferior vena cava was an incidental finding when a CT scan was done as a diagnostic procedure in a case of Hodgkin's disease. A short summary of the embryology and the significance of the variants is presented

  6. Tolosa-Hunt syndrome. A CT demonstration of a high-density lesion

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Kazuhiro; Muramoto, Masato; Chiba, Yasuhiro; Yagishita, Saburo

    1987-08-01

    CT scan studies of the Tolosa-Hunt syndrome have seldom been reported; positive abnormal findings are especially rare. A 36-year-old man suffered from steady, boring pain behind the left eye for one year. On admission he complained of diplopia on the right lateral gaze and hypesthesea of the first and second divisions of the left trigeminal nerve. A CT scan demonstrated a slightly high-density lesion, which was homogeneously enhanced, in the left cavernous portion and the superior orbital fissure. Carotid angiograms demonstrated no abnormal finding, and the cavernous sinus venography revealed no filling of the left cavernous sinus. A left front-temporal craniotomy was performed for the purpose of biopsy. A histological examination revealed non-specific focal granulomatous pachymeningitis. He responded dramatically to systemic steroid therapy, and he became pain-free by the fourth post-operative day. This diagnosis of the Tolosa-Hunt syndrome was confirmed both clinically and etiologically; however, the CT scan after the treatment demonstrated no definitive change in the lesion. The CT scan is useful for the diagnosis of this syndrome. Considering the stage of the illness, it is possible that the high-resolution CT scan can demonstrate this lesion with an advanced technique. The clinical diagnosis is almost easy, and surgical exploration is not always necessary if there is a prompt remission upon systemic steroid therapy. However, this syndrome should be differentiated from the other causes by appropriate examinations. Some cases similar to ours, especially suspected tumors, need surgical exploration because these angiographic findings are not specific.

  7. Diagnosis of nutcracker syndrome of the left renal vein. Value of the corticomedullary phase of helical CT

    International Nuclear Information System (INIS)

    Igari, Hidenori

    2001-01-01

    The clinical significance of the corticomedullary phase of helical CT in the diagnosis of nutcracker syndrome of the left renal vein (LRV) was evaluated. A total of 38 patients with hematuria of unknown origin (12 men and 26 women, mean age 24 years [range: 18-32 years]) were examined by helical CT of the kidneys, retrograde left renal venography, and measurement of renocaval pressure gradients. The sensitivity and specificity of the corticomedullary and nephrographic phases of helical CT for detecting the nutcracker syndrome were determined. The nutcracker syndrome was diagnosed on the basis of the renography findings combined with pressure measurements in 19 patients: 12 with LRV hypertension and collateral veins, 1 with hypertension and no collateral veins, and 6 with collateral veins and normal pressure gradients or borderline hypertension. Both the corticomedullary- and nephrographic-phase images revealed distended LRVs in 26 (68%) of the 38 patients. The LRV mean attenuation values in the corticomedullary phase (164±22 Hounsfield units [H], range: 138-209 H) was significantly greater (p<0.001) than in the nephrographic phase (80±14 H, range: 62-100 H). During the corticomedullary phase, opacified blood from the renal vein was mixed with unopacified blood in the IVC. In the nephrographic phase, however, the IVC was enhanced homogeneously, but only slightly. Corticomedullary-phase imaging detected collateral veins that exhibited early enhancement, indicating retrograde flow from the LRVs in 15 out of 18 patients (83% of those with collateral veins), while the nephrographic-phase imaging revealed collateral veins in 8 patients (44% of those with collateral veins). The sensitivity and specificity of the corticomedullary-phase scan for detecting the nutcracker syndrome were 79% and 100%, respectively, as opposed to 42% and 100%, respectively, for the nephrographic phase. Retrograde flow from the LRV into the collateral veins in the corticomedullary phase is a

  8. Right diaphragmatic rupture and hepatic hernia: an indirect sign on computed tomography

    International Nuclear Information System (INIS)

    Sadeghi, N.; Nicaise, N.; Struyven, J.; Gansbeke, D. van; DeBacker, D.

    1999-01-01

    We report a case of blunt traumatic right diaphragm rupture with hepatic hernia. The diagnosis was first suggested by an abnormal hepatic location depicted on axial CT. This finding can be considered as a potentially new indirect sign of right diaphragm rupture in patients with blunt trauma. The diagnosis was then confirmed by reformatted CT and MR images. (orig.)

  9. Multidetector-row computed tomography management of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Yasui, Takahiro; Tanabe, Nobuhiro; Terada, Jiro

    2007-01-01

    The purpose of this study was to evaluate the usefulness and safety of multidetector-row computed tomography (MDCT) pulmonary angiography and indirect venography management of acute pulmonary embolism (PE), including indication for inferior vena cava (IVC) filter. Seventy-one consecutive patients who were clinically suspected of PE and underwent 16-slice MDCT pulmonary angiography and indirect venography were enrolled. Management included indication of IVC filter for patients with extensive deep venous thrombosis (DVT) in submassive or massive PE. A right ventricular to left ventricular short-axis diameter by MDCT >1.0 was judged as submassive PE. All patients were followed for 1 year. MDCT identified 50 patients with venous thromboembolism and 47 patients had acute PE: 4 were judged as massive, 14 as submassive, and 29 as non-massive by MDCT; 3 patients had DVT alone and 7 patients had caval or iliac DVT. Only 1 patient with massive PE and DVT near the right atrium died of recurrence. No other patients died of PE. Management based on MDCT pulmonary angiography combined with indirect venography is considered to be safe and reliable in patients with suspected acute PE. (author)

  10. Anatomical variation of the main and right portal vein on indirect portogram : correlated with CT and hepatic angiogram

    International Nuclear Information System (INIS)

    Park, Won Kyu; Chang, Jae Chun; Bae, Kyoung Kug; Cho, Jae Ho

    1996-01-01

    To describe variations of the main and right portal veins as visualized by indirect portograms and to examine the surgical implications of these findings. A retrospective review was conducted of 632 indirect portograms of 632 patients in whom third-order branches were visualized. All patients also underwent dynamic CT and AP and oblique hepatic angiography. Variations of the main portal vein were found in 165 patients(26.1%) and involned an immediate trifurcation of the main portal vein in 102 patients(16.1%), early division of the right posterior portal vein in 53(8.4%), simultaneous division into four branches in three (0.5%), five branches in two (0.3%), a replaced P4 originating from the right portal vein in two (0.3%), and an accessory P6 originating from the main portal vein, a replaced P6 originating from the main protal vein, or a replaced left lateral portal vein originating from the right portal vein in one (0.2%), respectively. Of 468 patients who had a common right portal vein, absence of the right posterior portal vein was seen in 26 patients(5.6%) and an accessory subsegmental branch originating from the right portal vein in 17 patients(3.6%). Recognition of such variations of the portal vein assists in the localization and apperciation of the hepatic segmental anatomy, in preoperative evaluations for hepatic resections, and in radiologic interventional procedures through the portal vein

  11. Hexabrix (ioxaglate), a new low osmolality contrast agent for lumbar epidural double-catheter venography

    International Nuclear Information System (INIS)

    Meijenhorst, G.C.H.; Bruin, J.N.T. de

    1980-01-01

    Hexabrix (ioxaglate), a new low osmolality contrast agent, has been compared with Telebrix (ioxitalamate) in a series of 50 lumbar epidural venograms. The intensity of the pain and heat sensation experienced by the patient was significantly lower following the injection of Hexabrix. For this reason Hexabrix may be considered the contrast medium of choice for epidural venography. In 15 additional cases Hexabrix was compared with Amipaque (metrizamide) in the same iodine concentration (320 mg/ml). In these patients hardly any difference in pain and heat sensation was observed after the injection of both contrast agents. Frequently only a slight feeling of warmth was noticed. A minimal sensation of pain was occasionally observed to the same degree with both contrast agents. (orig.)

  12. Right diaphragmatic rupture and hepatic hernia: an indirect sign on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, N.; Nicaise, N.; Struyven, J.; Gansbeke, D. van [Department of Radiology, Hopital Erasme, Brussel (Belgium); DeBacker, D. [Intensive Care Unit, Hopital Erasme, Brussels (Belgium)

    1999-06-01

    We report a case of blunt traumatic right diaphragm rupture with hepatic hernia. The diagnosis was first suggested by an abnormal hepatic location depicted on axial CT. This finding can be considered as a potentially new indirect sign of right diaphragm rupture in patients with blunt trauma. The diagnosis was then confirmed by reformatted CT and MR images. (orig.) With 1 fig., 16 refs.

  13. Diagnosis of deep vein thrombosis using multi-detector helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya [Wakayama Medical Coll. (Japan)] [and others

    2002-11-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5{+-}7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  14. Diagnosis of deep vein thrombosis using multi-detector helical CT

    International Nuclear Information System (INIS)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya

    2002-01-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5±7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  15. CT findings in ileo-caval thrombosis

    International Nuclear Information System (INIS)

    Harder, T.; Distelmaier, W.; Koester, O.

    1982-01-01

    Thrombosis of a large vein can be demonstrated by CT. The thrombosed vein has a hyperdense lumen, with a somewhat increased diameter which does not opacify after intravenous contrast injection, but which shows a narrow hyperdense margin. Collateral vesels in the pelvic or paravertebral plexus and dilated veins in the abdominal skin are indirect evidence of ileo-caval thrombosis. CT can also demonstrate the cranial extent of a caval thrombosis. Venous thrombosis demonstrated by CT is an important additional finding in the pre-operative examination of the abdomen. (orig.) [de

  16. Magnetic resonance venography of congenital vascular malformations of the extremities

    International Nuclear Information System (INIS)

    Laor, T.; Burrows, P.E.; Hoffer, F.A.

    1996-01-01

    Contrast angiography can demonstrate the vascular components of a vascular malformation, but can be technically challenging in small patients with complex venous anomalies. We reviewed the role of magnetic resonance venography (MRV) in the evaluation of children with predominantly low-flow, vascular malformations of the extremities. MRV (2D time-of-flight technique) and magnetic resonance (MR) imaging examinations were performed in ten young patients with congential predominantly low-flow vascular malformations of the extremities. MR imaging was used to characterize and determine the extent of the malformations, and MRV to evaluate the deep and superficial venous channels. In all patients, MRV studies were reviewed in conjunction with contrast angiograms, considered the gold standard, to confirm the findings. All signficant channel anomalies seen with contrast angiography were identified with MRV. In addition, MRV demonstrated some veins that were not intentionally opacified during contrast studies. MRV demonstrates both the superficial and deep conducting veins, whereas contrast angiography is a more directed study, evaluating only those channels intentionally opacified. Together, MR imaging and MRV data can non-invasively form the basis for determining the prognosis and choosing the individual treatment of congenital vascular malformations of the extremities. (orig.)

  17. Upper limb vein anatomy before hemodialysis fistula creation: cross-sectional anatomy using MR venography

    International Nuclear Information System (INIS)

    Laissy, Jean-Pierre; Fernandez, Pedro; Karila-Cohen, Pascale; Chillon, Sylvie; Schouman-Claeys, Elisabeth; Delmas, Vincent; Dupuy, Emmanuel; Mignon, Francoise

    2003-01-01

    Preoperative imaging is indicated to discriminate patent, adequate superficial veins of the upper limbs undetectable by clinical inspection that could be anastomosed for the creation of a durable and functional hemodialysis fistula. The aim of this pictorial review is to provide a venous anatomic map of the upper limbs using MR venography (MRV) which could help surgeons before creation of hemodialysis access fistulas (AVF). At the level of the forearm, the antebrachial cephalic vein is the most commonly identified as patent. At the level of the elbow and distal arm, the cephalic vein is patent in 80% of normal subjects, and less often patent (23-26%) than basilic vein (33-38%) in patients. Overall, reading transaxial MR views can help for assessing upper limb vein anatomy before creation of a hemodialysis access fistula. (orig.)

  18. Upper limb vein anatomy before hemodialysis fistula creation: cross-sectional anatomy using MR venography

    Energy Technology Data Exchange (ETDEWEB)

    Laissy, Jean-Pierre; Fernandez, Pedro; Karila-Cohen, Pascale; Chillon, Sylvie; Schouman-Claeys, Elisabeth [Department of Radiology, Hopital Bichat, 46 rue Henri Huchard, 75877 Paris Cedex 18 (France); Delmas, Vincent [Department of Urology, Hopital Bichat, 46 rue Henri Huchard, 75877 Paris Cedex 18 (France); Dupuy, Emmanuel; Mignon, Francoise [Department of Nephrology, Hopital Bichat, 46 rue Henri Huchard, 75877 Paris Cedex 18 (France)

    2003-02-01

    Preoperative imaging is indicated to discriminate patent, adequate superficial veins of the upper limbs undetectable by clinical inspection that could be anastomosed for the creation of a durable and functional hemodialysis fistula. The aim of this pictorial review is to provide a venous anatomic map of the upper limbs using MR venography (MRV) which could help surgeons before creation of hemodialysis access fistulas (AVF). At the level of the forearm, the antebrachial cephalic vein is the most commonly identified as patent. At the level of the elbow and distal arm, the cephalic vein is patent in 80% of normal subjects, and less often patent (23-26%) than basilic vein (33-38%) in patients. Overall, reading transaxial MR views can help for assessing upper limb vein anatomy before creation of a hemodialysis access fistula. (orig.)

  19. Non-invasive assessment of congenital pulmonary vein stenosis in children using cardiac-non-gated CT with 64-slice technology

    International Nuclear Information System (INIS)

    Ou, Phalla; Marini, Davide; Celermajer, David S.; Agnoletti, Gabriella; Vouhe, Pascal; Sidi, Daniel; Bonnet, Damien; Brunelle, Francis

    2009-01-01

    Background: Management of congenital pulmonary vein stenosis is a diagnostic challenge. Echocardiography may be insufficient and thus cardiac catheterization remains the reference standard in this setting. The aim of the study was to investigate the accuracy of cardiac-non-gated CT using 64-slice technology in detecting congenital pulmonary vein stenosis in children. Materials and methods: CT examinations were consecutively performed from May 2005 to December 2006 in 13 children aged 1.5-12 months (median 5 months) for suspected congenital pulmonary vein stenosis. Cardiac-non-gated CT acquisitions were performed after the peripheral injection of contrast agent. Pulmonary veins were evaluated for their pattern of connectivity from the lung to the left atrium and for the presence of stenosis. CT findings of pulmonary vein stenosis were compared with combined findings available from echocardiography, catheterization and surgery. Results: Pulmonary veins from the right lung (n = 29) and left lung (n = 26) were evaluated as separate structures (N = 55). Of the 55 structures, 32 had surgical and/or catheterization data and 45 had echocardiography for comparison. CT visualized 100% (55/55) of the investigated structures, while echocardiography visualized 82% (45/55). In the 13 subjects CT identified 10 stenotic pulmonary veins. CT confirmed the echocardiography suspicion of pulmonary vein stenosis in 100% (7/7) and established a new diagnosis in 3 other patients. CT agreed with surgery/catheterization in 100% (10/10) of the available comparisons. Conclusion: Cardiac-non-gated CT assessed the pulmonary veins more completely than echocardiography and should be considered as a viable alternative for invasive pulmonary venography for detecting pulmonary vein stenosis in children.

  20. CT evaluation of sigmoid plate dehiscence causing pulsatile tinnitus

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Pengfei; Lv, Han; Dong, Cheng; Wang, Zhenchang [Capital Medical University, Department of Radiology, Beijing Friendship Hospital, Beijing (China); Niu, Yantao; Xian, Junfang [Capital Medical University, Department of Radiology, Beijing Tongren Hospital, Beijing (China)

    2016-01-15

    To evaluate the characteristics of sigmoid plate dehiscence (SPD) causing pulsatile tinnitus (PT) on CT arteriography and venography (CTA + V). Thirty PT patients treated successfully with SPD reconstruction were enrolled. Sixty asymptomatic patients were matched. The location, extent, number of SPD cases and concomitant signs, including venous outflow dominance, transverse sinus stenosis, high jugular bulb, temporal bone pneumatization, height of pituitary gland and pituitary fossa, abnormal mastoid emissary vein, were detected and compared using CTA + V. More than one SPD was found on the symptomatic side in 13/30 PT patients (43.3 %). The upper segment of the sigmoid plate was involved in 29/44 SPDs in the vertical direction (65.9 %); the lateral wall was involved in 38/44 SPDs in the horizontal direction (86.4 %). Singular SPD was detected in 3/60 asymptomatic patients (1.67 ± 0.35 mm{sup 2}), less so in PT patients (7.97 ± 5.17 mm{sup 2}). Compared with the control group, ipsilateral venous outflow dominance, high jugular bulb and bilateral transverse sinus stenosis were more common in the PT group, together with deeper pituitary fossa and flatter pituitary glands. SPD causing PT has characteristic CT findings. It may be generated by vascular or intracranial pressure abnormalities and act as a common key to triggering PT's perception. (orig.)

  1. CT evaluation of sigmoid plate dehiscence causing pulsatile tinnitus

    International Nuclear Information System (INIS)

    Zhao, Pengfei; Lv, Han; Dong, Cheng; Wang, Zhenchang; Niu, Yantao; Xian, Junfang

    2016-01-01

    To evaluate the characteristics of sigmoid plate dehiscence (SPD) causing pulsatile tinnitus (PT) on CT arteriography and venography (CTA + V). Thirty PT patients treated successfully with SPD reconstruction were enrolled. Sixty asymptomatic patients were matched. The location, extent, number of SPD cases and concomitant signs, including venous outflow dominance, transverse sinus stenosis, high jugular bulb, temporal bone pneumatization, height of pituitary gland and pituitary fossa, abnormal mastoid emissary vein, were detected and compared using CTA + V. More than one SPD was found on the symptomatic side in 13/30 PT patients (43.3 %). The upper segment of the sigmoid plate was involved in 29/44 SPDs in the vertical direction (65.9 %); the lateral wall was involved in 38/44 SPDs in the horizontal direction (86.4 %). Singular SPD was detected in 3/60 asymptomatic patients (1.67 ± 0.35 mm 2 ), less so in PT patients (7.97 ± 5.17 mm 2 ). Compared with the control group, ipsilateral venous outflow dominance, high jugular bulb and bilateral transverse sinus stenosis were more common in the PT group, together with deeper pituitary fossa and flatter pituitary glands. SPD causing PT has characteristic CT findings. It may be generated by vascular or intracranial pressure abnormalities and act as a common key to triggering PT's perception. (orig.)

  2. CT of the pulmonary ligament

    International Nuclear Information System (INIS)

    Godwin, J.D.; Vock, P.; Osborne, D.R.

    1983-01-01

    Most computed tomographic (CT) scans of the chest show the inferior pulmonary ligament and an associated septum in the lower lobe, although CT descriptions of these structures have not been reported. Conventional radiography of the ligament has relied on indirect signs: the position of the lower lobe in the presence of pneumothorax or pleural effusion, soft-tissue peaks along the upper surface of the diaphragm, and the rare traumatic paramediastinal pneumatocele (attributed to air in the ligament). CT clarifies the anatomic relations of the ligament and alterations caused by pleural effusion and pneumothorax. The ligament is probably responsible for some long linear shadows at the lung bases, and CT helps to distinguish these from scars, walls of bullae, and normal structures such as the phrenic nerve and the interlobar fissures

  3. CT of the pulmonary ligament

    Energy Technology Data Exchange (ETDEWEB)

    Godwin, J.D.; Vock, P.; Osborne, D.R.

    1983-08-01

    Most computed tomographic (CT) scans of the chest show the inferior pulmonary ligament and an associated septum in the lower lobe, although CT descriptions of these structures have not been reported. Conventional radiography of the ligament has relied on indirect signs: the position of the lower lobe in the presence of pneumothorax or pleural effusion, soft-tissue peaks along the upper surface of the diaphragm, and the rare traumatic paramediastinal pneumatocele (attributed to air in the ligament). CT clarifies the anatomic relations of the ligament and alterations caused by pleural effusion and pneumothorax. The ligament is probably responsible for some long linear shadows at the lung bases, and CT helps to distinguish these from scars, walls of bullae, and normal structures such as the phrenic nerve and the interlobar fissures.

  4. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic ...

  5. The clinical evaluation of radionuclide venography for the diagnosis of deep vein thrombosis

    International Nuclear Information System (INIS)

    Zhu Ruisen

    1992-01-01

    53 cases of deep vein thrombosis (DVT), 7 cases of post phlebitis syndrome (PPS), 3 cases of edema of leg with unknown etiology and 3 normal persons have been studied with radionuclide venography (RNV) using 99m Tc-MAA. The authors also analysed the relationships between the RNV images and the different course of diseases, acute, chronic phase, and summarized the imaging characteristics in PPS. Finally, the value of RNV in evaluation of the therapeutic effect of DVT patients was illustrated. The advantages and disadvantages of RNV, the cause of false positive and false negative have also been discussed. The sensitivity of RNV using 99m Tc-MAA was 85.2%, the specificity was 95.5%, the positive prevalence was 89.2%, and the negative prevalence rate was 93.7%. It was concluded that the RNV can be used for the diagnosis of DVT and pulmonary thrombosis at one injection, and was simple, feasible, sensitive and valuable one

  6. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  7. Experimental and clinical studies on CT lymphography

    International Nuclear Information System (INIS)

    Hirata, Yuzo; Kono, Michio

    1982-01-01

    Indirect lymphography using computed tomographic apparatus (CT Lymphography) was attempted in 15 dogs with newly devised contrast medium for the opacification of hilar and mediastinal lymphnodes. Clinical application was performed in 2 cases of lung cancer. Newly devised contrast material is an emulsion, which consists of oily contrast medium, non-ionic surfactant and glucose solution. The contrast medium was injected percutaneously into subdiaphragmatic space, or into bronchial walls by bronchofiberscopic technique. CT was able to demonstrate the opacified hilar and mediastinal nodes much more in number than demonstrated in conventional radiograms. It was true in 6 to 11 cases when injected into subdiaphragmatic spaces, and in 2 of 4 cases with an injection into bronchial walls. In clinical studies, CT revealed opacification of mediastinal nodes in one case of lung cancer. Although the procedure is still inferior to the demonstrability of routine indirect lymphography for the evaluation of the fine structure of each node, it showed no remarkable side effects. As the satisfactory method of opacifying hilar and mediastinal nodes has not yet been established, our method is thought to be of value in applying for detection of the metastatic lymphnodes. (author)

  8. Dynamic subtraction magnetic resonance venography: a new real time imaging technique for the detection of dural sinus thrombosis

    International Nuclear Information System (INIS)

    Mandel, C.; Birchall, D.; Connolly, D.; English, P.

    2002-01-01

    Full text: Requests for imaging suspected dural sinus thrombosis are increasing. Conventional magnetic imaging (MRI) and magnetic resonance venography (MRV) are often used to detect venous sinus thrombosis, but these techniques are prone to technical problems. Catheter angiography is sometimes required as the final arbiter in the evaluation of the dural venous sinuses. Recent technical developments in MR scanning have allowed the development of dynamic subtraction MRA. This technique is beginning to be applied to the assessment of intracranial vascular malformations. We have recently applied the technique to the imaging of the dural venous sinuses, and describe our early experience with the technique. Imaging was performed on a Philips Intera 1.5T scanner with gradient strength 33 mT and slew rate 130 T/m/sec. T1-weighed fast field echo imaging was performed (flip angle 400, TR 1.5 msec) during bolus injection of gadolinium (5ml gadolinium followed by a 10 ml saline chaser) at 5-6 ml/sec using a MRI-compatible pump injector. Slice thickness depended on the plane of acquisition, but was between 100- 150 mm. Images were acquired in three orthogonal projections in each case, using 3 separate contrast injections. Mask images were obtained before the arrival of contrast, and subtracted reconstructed images were obtained in real time, providing a dynamic display of the intracranial circulation including the dural venous sinuses. Frame rate was 1 frame per 0.8 seconds. We will present dynamic MR angiographic images in a number of patients. Normal appearances and those seen in venous sinus thrombosis will be presented in the video display. Dynamic MR venography is a new technique for the imaging of dural venous sinuses. In our practice, it has proved a valuable adjunct for the imaging of patients with dural venous sinus thrombosis. Copyright (2002) Blackwell Science Pty Ltd

  9. Gadobutrol versus gadofosveset-trisodium in MR venography of the lower extremities

    Energy Technology Data Exchange (ETDEWEB)

    Arnoldussen, Carsten W.K.P. [Maastricht University Medical Center, Department of Radiology, Maastricht (Netherlands); VieCuri Medical Center, Department of Radiology, Venlo (Netherlands); Lam, Yeelai [Maastricht University Medical Center, Department of Vascular Surgery, Maastricht (Netherlands); Ito, Nobutake [National Hospital Organization Tokyo Medical Center, Department of Diagnostic Radiology, Tokyo (Japan); Keio University Hospital, Department of Diagnostic Radiology, Tokyo (Japan); Winkens, Bjorn [Maastricht University, Department of Methodology and Statistics, Maastricht (Netherlands); Kooi, M.E.; Wildberger, Joachim E. [Maastricht University Medical Center, Department of Radiology, Maastricht (Netherlands); Maastricht University Medical Center, CARIM - School for Cardiovascular Diseases, Maastricht (Netherlands); Wittens, Cees H.A. [Maastricht University Medical Center, Department of Vascular Surgery, Maastricht (Netherlands); University Hospital RWTH Aachen, Department of Vascular Surgery, Aachen (Germany)

    2017-12-15

    MR venography (MRV) protocols have used bloodpool contrast agents and long scan sequences to identify patients suitable for treatment and preoperatively. However, variable availability of bloodpool contrast agents, high costs and a need to shorten acquisition times for routine MR protocols hamper everyday practice. 20 patients (11 men; mean age 54 ± 11.8 years; body mass index 23.6 ± 2.5) were enrolled in this prospective study. An intra-individual comparison of image quality, interpretation and findings for two different contrast agents (regular gadolinium contrast agent gadobutrol vs. bloodpool contrast agent gadofosveset-trisodium) and two different scan protocols (long acquisition time protocol using a high-resolution fast field echo (FFE) sequence vs. short acquisition time protocol using an ultra-fast gradient echo (GE) sequence) were performed. Image quality (average of 4.94 vs. 4.92 on a five-point scale), interpretation and contrast-to-noise ratio (44 vs. 45) were equal for both contrast agents. Image findings showed no statistical significant differences between the MR protocols or contrast agents (overall p = 0.328). For high-resolution MRV, it is possible to replace gadofosveset-trisodium with gadobutrol. Furthermore, an ultra-fast GE sequence for MRV might considerably shorten acquisition time, without loss of image quality or diagnostic yield. (orig.)

  10. Detection and characterization of Budd-Chiari syndrome with inferior vena cava obstruction: Comparison of fixed and flexible delayed scan time of computed tomography venography.

    Science.gov (United States)

    Zhou, Peng-Li; Wu, Gang; Han, Xin-Wei; Bi, Yong-Hua; Zhang, Wen-Guang; Wu, Zheng-Yang

    2017-06-01

    To compare the results of computed tomography venography (CTV) with a fixed and a flexible delayed scan time for Budd-Chiari syndrome (BCS) with inferior vena cava (IVC) obstruction. A total of 209 consecutive BCS patients with IVC obstruction underwent either a CTV with a fixed delayed scan time of 180s (n=87) or a flexible delayed scan time for good image quality according to IVC blood flow in color Doppler ultrasonography (n=122). The IVC blood flow velocity was measured using a color Doppler ultrasound prior to CT scan. Image quality was classified as either good, moderate, or poor. Image quality, surrounding structures and the morphology of the IVC obstruction were compared between the two groups using a χ 2 -test or paired or unpaired t-tests as appropriate. Inter-observer agreement was assessed using Kappa statistics. There was no significant difference in IVC blood flow velocity between the two groups. Overall image quality, surrounding structures and IVC obstruction morphology delineation on the flexible delayed scan time of CTV images were rated better relative to those obtained by fixed delayed scan time of CTV images (ptime of CTV. There were no significant differences in Kappa statistics between Group A and Group B. The flexible delayed scan time of CTV was associated with better detection and more reliable characterization of BCS with IVC obstruction compared to a fixed delayed scan time. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Neck after total laryngectomy: CT study

    International Nuclear Information System (INIS)

    DiSantis, D.J.; Balfe, D.M.; Hayden, R.E.; Sagel, S.S.; Sessions, D.; Lee, J.K.T.

    1984-01-01

    Computed tomographic scans in 23 patients who had undergone total laryngectomy were analyzed retrospectively to determine normal postoperative appearance and to evaluate the role of CT in assessing recurrent neoplasm. Nine patients without clinical evidence of recurrence illustrated the normal postoperative changes: a round or ovoid neopharynx connecting the base of the tongue with the cervical esophagus and intact fat planes surrounding the neopharynx, neurovascular bundles, and sternocleidomastoid muscles. In the 12 patients with recurrent neoplasm, the CT manifestations included masses involving the internal jugular lymph node chain, tracheostomy site, or paratracheal region. CT supplemented physical examination and indirect mirror examination, providing data regarding presence and extent of recurrent tumor and aiding in planning the mode and scope of therapy

  12. Development of a cone-beam CT system for radiological technologist education

    International Nuclear Information System (INIS)

    Teramoto, Atsushi; Ohara, Ken; Ozaki, Kaho; Miyashita, Mariko; Ohno, Tomoyuki; Tsuzaka, Masatoshi; Fujita, Hiroshi

    2011-01-01

    For radiological technologists, it is very important to understand the principle of computed tomography (CT) and CT artifacts derived from mechanical and electrical failure. In this study, a CT system for educating radiological technologists was developed. The system consisted of a cone-beam CT scanner and educational software. The cone-beam CT scanner has a simple structure, using a micro-focus X-ray tube and an indirect-conversion flat panel detector. For the educational software, we developed various educational functions of image reconstruction and reconstruction parameters as well as CT artifacts. In the experiments, the capabilities of the system were evaluated using an acrylic phantom. We verified that the system produced the expected results. (author)

  13. Generating Evidence for Clinical Benefit of PET/CT in Diagnosing Cancer Patients

    DEFF Research Database (Denmark)

    Vach, Werner; Høilund-Carlsen, Poul Flemming; Gerke, Oke

    2011-01-01

    For diagnostic methods such as PET/CT, not only diagnostic accuracy but also clinical benefit must be demonstrated. However, there is a lack of consensus about how to approach this task. Here we consider 6 clinical scenarios to review some basic approaches to demonstrating the clinical benefit...... of PET/CT in cancer patients: replacement of an invasive procedure, improved accuracy of initial diagnosis, improved accuracy of staging for curative versus palliative treatment, improved accuracy of staging for radiation versus chemotherapy, response evaluation, and acceleration of clinical decisions....... We also develop some guidelines for the evaluation of clinical benefit. First, it should be clarified whether there is a direct benefit of the use of PET/CT or an indirect benefit because of improved diagnostic accuracy. If there is an indirect benefit, then decision modeling should be used initially...

  14. Ranking of CT in persistent vertigo after implantation of stapes prostheses

    International Nuclear Information System (INIS)

    Koesling, S.; Woldag, K.; Meister, E.F.; Reschke, I.; Schulz, H.G.

    1995-01-01

    10 of 150 patients had persistent vertigo after implanation of stapes prostheses. These patients were evaluated by high resolution CT in the axial and coronal plane. Scans showed in all cases findings which related to the symptoms. The CT findings were proved intraoperatively in 9 cases. A new indirect sign of a perilymphatic fistula is described in form of an air bulla at the end of the prosthesis. Retympanotomy could be planned better with the help of HR-CT. (orig.) [de

  15. Does pain relief by CT-guided indirect cervical nerve root injection with local anesthetics and steroids predict pain relief after decompression surgery for cervical nerve root compression?

    Science.gov (United States)

    Antoniadis, Alexander; Dietrich, Tobias J; Farshad, Mazda

    2016-10-01

    The relationship of pain relief from a recently presented CT-guided indirect cervical nerve root injection with local anesthetics and steroids to surgical decompression as a treatment for single-level cervical radiculopathy is not clear. This retrospective study aimed to compare the immediate and 6-week post-injection effects to the short- and long-term outcomes after surgical decompression, specifically in regard to pain relief. Patients (n = 39, age 47 ± 10 years) who had undergone CT-guided indirect injection with local anesthetics and steroids as an initial treatment for single cervical nerve root radiculopathy and who subsequently needed surgical decompression were included retrospectively. Pain levels (VAS scores) were monitored before, immediately after, and 6 weeks after injection (n = 34), as well as 6 weeks (n = 38) and a mean of 25 months (SD ± 12) after surgical decompression (n = 36). Correlation analysis was performed to find potential associations of pain relief after injection and after surgery to investigate the predictive value of post-injection pain relief. There was no correlation between immediate pain relief after injection (-32 ± 27 %) and 6 weeks later (-7 ± 19 %), (r = -0.023, p = 0.900). There was an association by tendency between immediate pain relief after injection and post-surgical pain relief at 6 weeks (-82 ± 27 %), (r = 0.28, p = 0.08). Pain relief at follow-up remained high at -70 ± 21 % and was correlated with the immediate pain amelioration effect of the injection (r = 0.37, p = 0.032). Five out of seven patients who reported no pain relief from injection had a pain relief from surgery in excess of 50 %. The amount of immediate radiculopathic pain relief after indirect cervical nerve root injection is associated with the amount of pain relief achieved at long-term follow-up after surgical decompression of single-level cervical radiculopathy

  16. Abnormal skull shape

    International Nuclear Information System (INIS)

    Blaser, Susan I.

    MRI may be required in cases at risk of acquired tonsillar herniation or central nervous system anomalies. Additional CT or MR venography or catheter angiography may be necessary to map anomalous or vigorous collateral venous drainage preoperatively. (orig.)

  17. CT and MR imaging after middle ear surgery

    International Nuclear Information System (INIS)

    Koesling, Sabrina; Bootz, F.

    2001-01-01

    This article describes the current value of imaging in patients after stapes surgery and surgery after chronic otitis media including cholesteatoma. Possibilities and limits of computed tomography (CT) and MRI are described and most important investigation parameters are mentioned. After otosclerosis surgery, CT is the method of first choice in detection of reasons for vertigo and/or recurrent hearing loss in the later postoperative phase. CT may show the position and condition of prosthesis, scarring around the prosthesis and otospongiotic foci. Sometimes, it gives indirect hints for perilymphatic fistulas and incus necrosis. MRI is able to document inner ear complications. CT has a high negative predictive value in cases with a free cavity after mastoidectomy. Localized opacities or total occlusion are difficult to distinguish by CT alone. MRI provides important additional information in the differentiation of cholesterol granuloma, cholesteatoma, effusion, granulation and scar tissue

  18. CT and MR imaging after middle ear surgery

    Energy Technology Data Exchange (ETDEWEB)

    Koesling, Sabrina E-mail: sabrina.koesling@medizin.uni-halle.de; Bootz, F

    2001-11-01

    This article describes the current value of imaging in patients after stapes surgery and surgery after chronic otitis media including cholesteatoma. Possibilities and limits of computed tomography (CT) and MRI are described and most important investigation parameters are mentioned. After otosclerosis surgery, CT is the method of first choice in detection of reasons for vertigo and/or recurrent hearing loss in the later postoperative phase. CT may show the position and condition of prosthesis, scarring around the prosthesis and otospongiotic foci. Sometimes, it gives indirect hints for perilymphatic fistulas and incus necrosis. MRI is able to document inner ear complications. CT has a high negative predictive value in cases with a free cavity after mastoidectomy. Localized opacities or total occlusion are difficult to distinguish by CT alone. MRI provides important additional information in the differentiation of cholesterol granuloma, cholesteatoma, effusion, granulation and scar tissue.

  19. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Radiologist and patient consultation. View full size ... X-Ray and CT Exams Contrast Materials Venography Images related to Transjugular Intrahepatic Portosystemic Shunt (TIPS) Sponsored ...

  20. Intra- and Extracranial MR Venography: Technical Notes, Clinical Application, and Imaging Development

    Directory of Open Access Journals (Sweden)

    M. Paoletti

    2016-01-01

    Full Text Available Scientific debate over chronic cerebrospinal venous insufficiency (CCSVI has drawn attention to venous system involvement in a series of pathologic brain conditions. In the last few decades, the MRI venography (MRV field has developed a number of valuable sequences to better investigate structural anatomy, vessel patency, and flow characteristics of venous drainage in the intra- and extracranial systems. A brief two-tier protocol is proposed to encompass the study of intra- and extracranial venous drainage with and without contrast administration, respectively. Contrast-enhanced protocol is based on time-resolved contrast-enhanced MRV of the whole region plus extracranial flow quantification through 2D Cine phase contrast (PC; non-contrast-enhanced protocol includes intracranial 3D PC, extracranial 2D time of flight (TOF, and 2D Cine PC flow quantification. Total scanning time is reasonable for clinical applications: approximately seven minutes is allocated for the contrast protocol (most of which is due to 2D Cine PC, while the noncontrast protocol accounts for around twenty minutes. We believe that a short though exhaustive MRI scan of the whole intra- and extracranial venous drainage system can be valuable for a variety of pathologic conditions, given the possible venous implication in several neurological conditions.

  1. The diagnostic accuracy of magnetic resonance venography in the detection of deep venous thrombosis: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Abdalla, G.; Fawzi Matuk, R.; Venugopal, V.; Verde, F.; Magnuson, T.H.; Schweitzer, M.A.; Steele, K.E.

    2015-01-01

    Aim: To search the literature for further evidence for the use of magnetic resonance venography (MRV) in the detection of suspected DVT and to re-evaluate the accuracy of MRV in the detection of suspected deep vein thrombosis (DVT). Materials and methods: PubMed, EMBASE, Scopus, Cochrane, and Web of Science were searched. Study quality and the risk of bias were evaluated using the QUADAS 2. A random effects meta-analysis including subgroup and sensitivity analyses were performed. Results: The search resulted in 23 observational studies all from academic centres. Sixteen articles were included in the meta-analysis. The summary estimates for MRV as a diagnostic non-invasive tool revealed a sensitivity of 93% (95% confidence interval [CI]: 89% to 95%) and specificity of 96% (95% CI: 94% to 97%). The heterogeneity of the studies was high. Inconsistency (I2) for sensitivity and specificity was 80.7% and 77.9%, respectively. Conclusion: Further studies investigating the use of MRV in the detection of suspected DVT did not offer further evidence to support the replacement of ultrasound with MRV as the first-line investigation. However, MRV may offer an alternative tool in the detection/diagnosis of DVT for whom ultrasound is inadequate or not feasible (such as in the obese patient). -- Highlights: •We aimed to search the literature for evidence for the use of MRV in the detection of suspected DVT. •We questioned the use of MRV in special populations like the obese where contrast venography may not be feasible or safe. •MRV may not replace ultrasound as the first-line modality for DVT detection. •Consider MRV use in special populations like the obese where other diagnostic tools are not feasible. •Studies to compare MRV vs. ultrasound as a screening tool for DVT in the obese should be considered

  2. Hyperemic peripheral red marrow in a patient with sickle cell anemia demonstrated on Tc-99m labeled red blood cell venography

    International Nuclear Information System (INIS)

    Heiden, R.A.; Locko, R.C.; Stent, T.R.

    1991-01-01

    A 25-year-old gravid woman, homozygous for sickle cell anemia, with a history of recent deep venous thrombosis, was examined using Tc-99m labeled red blood cell venography for recurrent thrombosis. Although negative for thrombus, the study presented an unusual incidental finding: the patient's peripheral bone marrow was hyperemic in a distribution consistent with peripheral red bone marrow expansion. Such a pattern has not been documented before using this technique. This report supports other literature that has demonstrated hyperemia of peripheral red bone marrow in other hemolytic anemias. This finding may ultimately define an additional role of scintigraphy in assessing the pathophysiologic status of the sickle cell patient

  3. Transjugular Intrahepatic Portosystemic Shunt (TIPS)

    Medline Plus

    Full Text Available ... so as not to expose the fetus to radiation. If an x-ray is necessary, precautions will be taken to ... denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Contrast Materials Venography Images ...

  4. Iterative Metallic Artifact Reduction for In-Plane Gonadal Shielding During Computed Tomographic Venography of Young Males.

    Science.gov (United States)

    Choi, Jin Woo; Lee, Sang Yub; Kim, Jong Hyo; Jin, Hyeongmin; Lee, Jaewon; Choi, Young Hun; Lee, Hyeon-Kyeong; Park, Jae Hyung

    The purpose of this study was to evaluate a gonadal shield (GS) and iterative metallic artifact reduction (IMAR) during computed tomography scans, regarding the image quality and radiation dose. A phantom was imaged with and without a GS. Prospectively enrolled, young male patients underwent lower extremity computed tomography venography (precontrast imaging without the GS and postcontrast imaging with the GS). Radiation dose was measured each time, and the GS-applied images were reconstructed by weighted filtered back projection and IMAR. In the phantom study, image artifacts were significantly reduced by using IMAR (P = 0.031), whereas the GS reduced the radiation dose by 61.3%. In the clinical study (n = 29), IMAR mitigated artifacts from the GS, thus 96.6% of the IMAR image sets were clinically usable. Gonadal shielding reduced the radiation dose to the testes by 69.0%. The GS in conjunction with IMAR significantly reduced the radiation dose to the testes while maintaining the image quality.

  5. CT manifestation of peritoneal metastasis

    International Nuclear Information System (INIS)

    Cha, Soon Joo; Kang, Eun Young; Suh, Won Hyuck

    1989-01-01

    Peritoneal metastasis is frequent mode of dissemination of intraabdominal malignancies. Radiologic diagnosis of peritoneal metastasis has relied on indirect evidence on a barium UGI series and small bowel examination. With the advent of CT scanning, CT is capable of direct imaging of peritoneum. The sensitivity of CT in detecting peritoneal metastasis and CT manifestation of peritoneal metastatic lesions had reported occasionally, but rarely in Korea. So, authors illustrated the CT manifestation of peritoneal metastatic lesions in 32 cases of macroscopically proven cases in laparoscopy or laparotomy in Korea University Hae Wha Hospital during recent 4 years. The results are as follows. 1. Of total 32 cases, 18 cases were male and 14 cases were female. Age incidence was the most common in 6th decade. 2. The most common type of malignancy that cause peritoneal metastasis was the stomach cancer and next common type of malignancies were pancreas cancer in men and ovarian cancer in women. 3. Of total 32 cases of peritoneal metastasis which was confirmed by laparoscopy or laparotomy macroscopically, 23 cases (72%) were detected peritoneal thickening and/or omental pathology by CT, and the remaining 9 cases (28%) were not detected by CT. 4. Ascites was present in 19 cases (59%). 5. Parietal peritoneal thickening was present in 16 cases (50%) by CT and sheetlike pattern was the most common findings. The patterns of peritoneal thickening was relatively nonspecific and was not correlated with primary tumor type. 6. Tumor involvement of greater omentum by CT was present in 19 cases (59%). There were 7 cases of smudged appearance pattern, 6 cases of nodular pattern, 6 cases of omental cake pattern and no cystic mass pattern. The patterns of omental pathology was relatively nonspecific and was nor correlated with primary tumor type

  6. Hydatid disease of the spleen; Ultrasonography, CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sinner, W.N. von; Stridbeck, H. (Dept. of Diagnostic Radiology, King Faisal Specialist Hospital, and Research Center, Riyadh (Saudi Arabia) Lund Univ. Hospital (Sweden))

    1992-09-01

    Seven patients with hydatid disease of the spleen were examined by radiography, ultrasound, CT, and in one case MR imaging. The observations were confirmed by patho-anatomic findings except in 2 patients where high indirect hemagglutination tests confirmed the diagnosis. (orig./MG).

  7. CT appearance and features of tubal pregnancy

    Energy Technology Data Exchange (ETDEWEB)

    Xiaohong, Wang; Hong, Shan; Zaibo, Jiang; Xinghe, Deng; Xiaochun, Meng; Bingbing, Ye; Mingyue, Luo; Yunya, Lin [Sun Yat-sen Univ., Guangzhou (China). The Third Univ. Hospital, Dept. of Radiology

    2004-06-01

    Objective: To investigate the CT appearance and features of tubal pregnancy. Methods: Precontrast and postcontrast CT scans were employed in 38 patients who were clinically and ultrasonographically suspected of tubal pregnancy. 34 of them were verified as tubal pregnancy through operative pathology. Results: 1. The direct CT imaging feature was the whole pregnancies sac (4/34, 11.8%) or half-baked pregnancies sac (14/34, 41.2%); 2. The indirect CT imaging features were: (1) abnormal density image, which could be enhanced, in a cystic mass around adnexal area (8/34, 23.5%); (2) mix density mass around adnexal area, which was mainly solid and had mild to moderate inhomogeneous enhancement (19/34, 55.9%); (3) large area irregular shadow with high density were found beside the uterus, with no enhancement (3/34, 8.8%). (4) bloody density in uterus-rectum-fossa (23/34, 67.6%). 3. The CT imaging features of tubal pregnancy was classified as: (1) Pregnant sac type (4/34, 11.8%); (2) Cystic (8/34, 23.5%); (3) Massive type (17/34, 50%); (4) Chronic mass type (2/34, 5.9%); (5) Bleeding type (3/34, 8.8%). 4. The CT imaging appearance of tubal pregnancy related with the pregnancy location; 5. The CT imaging appearance of tubal pregnancy related with the clinical significant. Conclusion: The CT imaging appearance of tubal pregnancy has some features, which can help in the diagnosis or differential diagnosis of the pelvis masses. CT scan is an effective supplementary attempt to the clinically and ultrasonographically suspected tubal pregnancy patients.

  8. CT appearance and features of tubal pregnancy

    International Nuclear Information System (INIS)

    Wang Xiaohong; Shan Hong; Jiang Zaibo; Deng Xinghe; Meng Xiaochun; Ye Bingbing; Luo Mingyue; Lin Yunya

    2004-01-01

    Objective: To investigate the CT appearance and features of tubal pregnancy. Methods: Precontrast and postcontrast CT scans were employed in 38 patients who were clinically and ultrasonographically suspected of tubal pregnancy. 34 of them were verified as tubal pregnancy through operative pathology. Results: 1. The direct CT imaging feature was the whole pregnancies sac (4/34, 11.8%) or half-baked pregnancies sac (14/34, 41.2%); 2. The indirect CT imaging features were: (1) abnormal density image, which could be enhanced, in a cystic mass around adnexal area (8/34, 23.5%); (2) mix density mass around adnexal area, which was mainly solid and had mild to moderate inhomogeneous enhancement (19/34, 55.9%); (3) large area irregular shadow with high density were found beside the uterus, with no enhancement (3/34, 8.8%). (4) bloody density in uterus-rectum-fossa (23/34, 67.6%). 3. The CT imaging features of tubal pregnancy was classified as: (1) Pregnant sac type (4/34, 11.8%); (2) Cystic (8/34, 23.5%); (3) Massive type (17/34, 50%); (4) Chronic mass type (2/34, 5.9%); (5) Bleeding type (3/34, 8.8%). 4. The CT imaging appearance of tubal pregnancy related with the pregnancy location; 5. The CT imaging appearance of tubal pregnancy related with the clinical significant. Conclusion: The CT imaging appearance of tubal pregnancy has some features, which can help in the diagnosis or differential diagnosis of the pelvis masses. CT scan is an effective supplementary attempt to the clinically and ultrasonographically suspected tubal pregnancy patients

  9. Preoperative assessment of gastric artery in patients with gastric cancer by CT angiography on 64-slice spiral CT

    International Nuclear Information System (INIS)

    Tang Lei; Zhang Xiaopeng; Sun Yingshi; Cao Kun; Qi Liping; Cui Yong; Wang Ning

    2010-01-01

    Objective: To evaluate the efficacy of different three-dimensional CTA methods on 64-slice sprial CT in the preoperative assessment of gastric arteries and their variations. Methods: Sixty-six consecutive patients with gastric cancer who underwent 64-slice spiral CT examinations preoperatively were retrospectively studied. To get the STS-MIP images, the thickness of slab was adjusted according to the inner diameter of targeted blood vessels and their cross-layer distribution. After four weeks, the AVVR images of all cases was got by the auto-vessel technique. The demonstration rates and origins of the direct and indirect feeding arteries were analyzed on AVVR and STS-MIP. McNemar tests were used to compare the detection rates of gastric feeding arteries by STS-MIP and AVVR. The relationship between CT value and display rate of vessels was analyzed using independent-samples t test. The variations of blood vessels were analyzed. Results: The display rate of indirect feeding arteries were all 100% (66/66) by STS-MIP and AVVR. The display rates of left gastric artery (LGA) and right gastroepiploic artery (RGEA) were 98.5% (65/66), 100.0% (66/66) and 97.0% (64/66), 100.0% (66/66) by STS-MIP and AVVR respectively. The display rates of right artery (RGA), left gastroepiploic artery (LGEA), short gastric artery (SGA) and posterior gastric artery (RGA), left gastroepiploic artery (LGEA), short gastric artery (SGA) and posterior gastric artery (PGA) by AVVR were lower than those of STS-MIP with statistical significances [RGA: 68.2% (45/66) vs. 98.5% (65/66), P<0.01; LGEA: 53.0% (35/66) vs. 97.0% (64/66), P<0.01; SGA: 7.6%(5/66) vs. 59.1% (39/66), P<0.01; PGA: 18.2% (12/66) vs. 63.6% (42/66), P<0.01]. The demonstration rates of LGEA, RGEA and SGA increased accompanied with the increasing of CT value in celiac axis (LGEA: 35 cases displayed with mean CT value of (272 ± 44) HU, 31 cases did not display with mean CT value of (229 ± 42) HU, t=4.043, P<0.01; RGEA: 64 cases

  10. MR Venography of Deep Veins: Changes with Uterine Fibroid Embolization

    International Nuclear Information System (INIS)

    Katsumori, Tetsuya; Kasahara, Toshiyuki; Tsuchida, Yoko; Nara, Yoshinori

    2009-01-01

    Deep veins (DVs) can be compressed by a uterus enlarged with fibroids. The purpose of this study was to assess the degree of luminal narrowing of DVs caused by a myomatous uterus, and the change in DV narrowing in women with symptomatic fibroids after embolization using time-of-flight (TOF)-magnetic resonance venography (MRV). Twenty-nine consecutive women with symptomatic uterine fibroids underwent TOF-MRV and pelvic MRI before and 4 months after embolization. Based on the TOF-MRV, we evaluated the luminal narrowing of three DVs, including the inferior vena cava, and the bilateral common and external iliac veins, and divided the findings into three grades. The scores for each DV were added for each patient (lowest, 0; highest, 6). DV scores and symptom severity (SS) scores were compared between the baseline and 4 months after embolization using the paired t-test. The relationship between DV scores and uterine volume was investigated using Pearson's test. DV scores decreased significantly, from 1.52 ± 1.70 at baseline to 0.93 ± 1.56 at 4 months after embolization (p = 0.004). The uterine volume decreased from 948 ± 647 mL at baseline to 617 ± 417 mL at 4 months after embolization (p < 0.001). DV score correlated with uterine volume (r = 0.856, p < 0.001). SS scores decreased from 54.5 ± 14.6 at baseline to 26.8 ± 15.4 at 4 months after embolization (p < 0.001). In conclusion, the degree of luminal narrowing of DVs caused by a uterus with fibroids is correlated with the uterine volume. Uterine artery embolization may induce an improvement of luminal narrowing of DVs due to a reduction of the myomatous uterus volume.

  11. Confirmation of T1-Bright Vein of Galen Aneurysm Spontaneous Thrombosis by Subtraction Magnetic Resonance Venography: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Irfan, M.; Lohman, B.; McKinney, A.M. (Dept. of Radiology/Neuroradiology, Univ. of Minnesota, Minneapolis, Minnesota (United States))

    2009-08-15

    Spontaneous thrombosis of a vein of Galen aneurysmal malformation (VOGM) is rare. We describe a 2-month-old patient with a patent VOGM and hydrocephalus, also confirmed patent at 6 months, but with subsequent lack of filling on pre-embolization catheter digital subtraction angiography (DSA) at 9 months' age. Due to the presence of T1- and T2-bright signal, noncontrast T1-weighted images (T1WI), T2-weighted images (T2WI), two-dimensional (2D) time-of-flight (TOF) magnetic resonance venography (MRV), and postcontrast T1WI were ambiguous for patency. However, subtracting the pre- from the postcontrast MRV images confirmed closure compared to subtracted images at 6 months' age. The factors contributing to thrombosis were likely a combination of a disproportionately small straight sinus, ventriculostomy, and contrast medium from DSA.

  12. A differentiated approach to the diagnosis of pulmonary embolism and deep venous thrombosis using multi-slice CT

    International Nuclear Information System (INIS)

    Wildberger, J.E.; Mahnken, A.H.; Stargardt, A.; Haage, P.; Guenther, R.W.; Sinha, A.M.; Schaller, S.

    2002-01-01

    Purpose: To establish a differentiated protocol for multi-slice CT (MSCT) examinations in cases of clinically suspected pulmonary embolism (PE) using pulmonary CT-angiography (CTA) and indirect CT-phlebography (CTP). Materials and Methods: 161 patients with suspected PE were examined using an MSCT (SOMATOM Volume Zoom; Siemens, Forchheim, Germany). After intravenous administration of 120 ml of contrast material, a thin collimation chest-CT scan was performed (120 kV, 100 mAs, collimation: 4 x 1 mm). If PE was present, or previous examinations and clinical signs suggested deep venous thrombosis (DVT), a CTP was subsequently completed. CTPs were performed using a 4 x 5 mm protocol (120 kV, 170 mAs). Venous phase scanning, starting from the pelvic crest, was completed in the popliteal fossa three minutes after contrast material injection. In 73 extremities, CTP were compared to the results of ultrasound, phlebography and autopsy. Scan ranges were documented in all patients. Cumulative doses were calculated for male and female subgroups. Results: 62 patients in our series suffered from PE and in 47 of these patients deep venous thrombosis was seen additionally. Of the 99 patients without PE, 47 also received indirect CTP. CTP confirmed the suspicion and extent of DVT in 8 patients. Only in 2 of 39 patients (5.1%) was previously unknown DVT found, despite the exclusion of PE. Regarding DVT, sensitivity was 94.3% and specificity was 92.1% for indirect CTP. Cumulative chest CT doses averaged 3.3 mSv for males and 4.2 mSv for females, the calculated CTP dosage was 9.3 mSv (according to ICRP 60). Conclusions: the examination protocol presented its suitable for clinical usage in patients with suspected PE. If PE is confirmed, indirect CTP is justified, so that detailed information of the venous system can be obtained. However, the relatively high radiation dosage of an additional CTP requires a strict indication regiment in patients with a negative CTA. (orig.) [de

  13. PET-CT in oncological patients: analysis of informal care costs in cost-benefit assessment.

    Science.gov (United States)

    Orlacchio, Antonio; Ciarrapico, Anna Micaela; Schillaci, Orazio; Chegai, Fabrizio; Tosti, Daniela; D'Alba, Fabrizio; Guazzaroni, Manlio; Simonetti, Giovanni

    2014-04-01

    The authors analysed the impact of nonmedical costs (travel, loss of productivity) in an economic analysis of PET-CT (positron-emission tomography-computed tomography) performed with standard contrast-enhanced CT protocols (CECT). From October to November 2009, a total of 100 patients referred to our institute were administered a questionnaire to evaluate the nonmedical costs of PET-CT. In addition, the medical costs (equipment maintenance and depreciation, consumables and staff) related to PET-CT performed with CECT and PET-CT with low-dose nonenhanced CT and separate CECT were also estimated. The medical costs were 919.3 euro for PET-CT with separate CECT, and 801.3 euro for PET-CT with CECT. Therefore, savings of approximately 13% are possible. Moreover, savings in nonmedical costs can be achieved by reducing the number of hospital visits required by patients undergoing diagnostic imaging. Nonmedical costs heavily affect patients' finances as well as having an indirect impact on national health expenditure. Our results show that PET-CT performed with standard dose CECT in a single session provides benefits in terms of both medical and nonmedical costs.

  14. Imaging in pulsatile tinnitus

    International Nuclear Information System (INIS)

    Madani, G.; Connor, S.E.J.

    2009-01-01

    Tinnitus may be continuous or pulsatile. Vascular lesions are the most frequent radiologically demonstrable cause of pulsatile tinnitus. These include congenital vascular anomalies (which may be arterial or venous), vascular tumours, and a variety of acquired vasculopathies. The choice of imaging depends on the clinical findings. If a mass is present at otoscopy, thin-section computed tomography (CT) is indicated. In the otoscopically normal patient, there is a range of possible imaging approaches. However, combined CT angiography and venography is particularly useful

  15. Imaging in pulsatile tinnitus

    Energy Technology Data Exchange (ETDEWEB)

    Madani, G. [Radiology Department, St Mary' s Hospital, London (United Kingdom)], E-mail: gittamadani@yahoo.com; Connor, S E.J. [Neuroradiology Department, King' s College Hospital, London (United Kingdom)

    2009-03-15

    Tinnitus may be continuous or pulsatile. Vascular lesions are the most frequent radiologically demonstrable cause of pulsatile tinnitus. These include congenital vascular anomalies (which may be arterial or venous), vascular tumours, and a variety of acquired vasculopathies. The choice of imaging depends on the clinical findings. If a mass is present at otoscopy, thin-section computed tomography (CT) is indicated. In the otoscopically normal patient, there is a range of possible imaging approaches. However, combined CT angiography and venography is particularly useful.

  16. Utilizing optical coherence tomography for CAD/CAM of indirect dental restorations

    Science.gov (United States)

    Chityala, Ravishankar; Vidal, Carola; Jones, Robert

    Optical Coherence Tomography (OCT) has seen broad application in dentistry including early carious lesion detection and imaging defects in resin composite restorations. This study investigates expanding the clinical usefulness by investigating methods to use OCT for obtaining three-dimensional (3D) digital impressions, which can be integrated to CAD/CAM manufacturing of indirect restorations. 3D surface topography `before' and `after' a cavity preparation was acquired by an intraoral cross polarization swept source OCT (CP-OCT) system with a Micro-Electro-Mechanical System (MEMS) scanning mirror. Image registration and segmentation methods were used to digitally construct a replacement restoration that modeled the original surface morphology of a hydroxyapatite sample. After high resolution additive manufacturing (e.g. polymer 3D printing) of the replacement restoration, micro-CT imaging was performed to examine the marginal adaptation. This study establishes the protocol for further investigation of integrating OCT with CAD/CAM of indirect dental restorations.

  17. How to manage RI venography in pre-orthopedic surgery patients

    International Nuclear Information System (INIS)

    Terazawa, Kaori; Otsuka, Hideki; Otomi, Yoichi; Morita, Naomi; Takao, Shoichiro; Iwamoto, Seiji; Osaki, Kyosuke; Harada, Masafumi; Nishitani, Hiromu

    2010-01-01

    The preoperative evaluation of venous thromboembolism (VTE) is important to avoid complications, because VTE is often induced by orthopedic surgery. We focused on radioisotope venography (RIV) using 99m Tc-macroaggregated human serum albumin, examining orthopedic patients. We conducted 34 examinations in 33 patients who were referred for RIV and lung perfusion scintigraphy for the pre-orthopedic operative evaluation of VTE. Two board-certified (one nuclear medicine board-certified) radiologists interpreted the images based on the following: flow defect of the lower extremities; interruption of flow; irregular or asymmetric filling of the deep vein (low flow); presence of collateral vessels; and abnormal RI retention on delayed-phase images. Scoring was based on a 5-point scale, and more than 2 points was considered VTE positive. Abnormal findings were noted in 27 of the 34 examinations performed in the 33 patients and normal findings in the other 7 examinations. According to the RI score, 21 patients were classified into the VTE-positive group and 12 into the VTE-negative group. Surgery was canceled because of advanced age and respiratory dysfunction in 2 of the 21 patients in the VTE-positive group. Of the 19 patients who underwent surgery, an IVH filter was placed before surgery in 2 and anticoagulant treatment with heparin and warfarin was initiated on the day of surgery in 12 to prevent postoperative VTE, and only one of the patients receiving anticoagulant treatment developed PTE after surgery. Surgery was canceled due to advanced age and at patient's request in 2 of 12 patients in the VTE-negative group. Anticoagulant treatment with heparin/warfarin was performed to prevent postoperative VTE in only 3 patients: one with a past medical history of pulmonary infarction, one with atrial fibrillation, and one suspected of having antiphospholipid antibody syndrome. No patient in the VTE-negative group developed VTE after surgery. The preoperative identification of

  18. Gastro-duodenal perforations: conventional plain film, US and CT findings in 166 consecutive patients

    International Nuclear Information System (INIS)

    Grassi, Roberto; Romano, Stefania; Pinto, Antonio; Romano, Luigia

    2004-01-01

    Introduction: Gastro-duodenal perforations may be suspected in patients with history of ulceration, who present with acute pain and abdominal wall rigidity, but radiological findings in these cases may be unable to confirm a clinical diagnosis. The aim of our study was to report our experience in the diagnosis of gastro-duodenal perforation by conventional radiography, US and CT examinations. Material and methods: We retrospectively reviewed medical records of 166 consecutive patients who presented in the last 2 years to our institutions with symptoms of acute abdomen and submitted to surgery at the Emergency Unit of the ''A.Cardarelli'' Hospital of Naples with a surgical finding of perforated gastro-duodenal ulcer. The evidence of free intraperitoneal air on abdominal plain film was considered as a direct or suggestive finding of perforation. Evidence of intraperitoneal free fluid and/or reduced intestinal peristalsis at sonographic examination were considered indirect signs of gastro-duodenal perforation. Evidence of free peritoneal gas at CT was considered as a direct evidence of gastro-duodenal perforation. Results: Twenty patients underwent immediate surgery with no preoperative imaging evaluation, in 10 of them the site of perforation was found in a juxta-pyloric region and in the others at level of duodenum. In 146 patients submitted to serial radiological investigations before surgery, the site of perforation was in 56 (38.3%) duodenal, in 52 (35.6%) juxta-pyloric, in 28 (19.1%) gastric and in 10 (6.8%) pyloric. The cause of perforation was in all cases gastric or duodenal ulceration, in seven cases involving pancreatic parenchyma. In 110 (75.4%) patients with direct findings of perforation, in 94 cases (85.5%) the correct diagnosis was established on abdominal plain film, in two (1.8%) with radiographic and sonographic examinations and in 14 (12.7%) on CT findings. In 36 (24,6%) patients with no direct findings of perforation, only 24 (16,4%) of them

  19. Gastro-duodenal perforations: conventional plain film, US and CT findings in 166 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Grassi, Roberto; Romano, Stefania E-mail: stefromano@libero.it; Pinto, Antonio; Romano, Luigia

    2004-04-01

    Introduction: Gastro-duodenal perforations may be suspected in patients with history of ulceration, who present with acute pain and abdominal wall rigidity, but radiological findings in these cases may be unable to confirm a clinical diagnosis. The aim of our study was to report our experience in the diagnosis of gastro-duodenal perforation by conventional radiography, US and CT examinations. Material and methods: We retrospectively reviewed medical records of 166 consecutive patients who presented in the last 2 years to our institutions with symptoms of acute abdomen and submitted to surgery at the Emergency Unit of the ''A.Cardarelli'' Hospital of Naples with a surgical finding of perforated gastro-duodenal ulcer. The evidence of free intraperitoneal air on abdominal plain film was considered as a direct or suggestive finding of perforation. Evidence of intraperitoneal free fluid and/or reduced intestinal peristalsis at sonographic examination were considered indirect signs of gastro-duodenal perforation. Evidence of free peritoneal gas at CT was considered as a direct evidence of gastro-duodenal perforation. Results: Twenty patients underwent immediate surgery with no preoperative imaging evaluation, in 10 of them the site of perforation was found in a juxta-pyloric region and in the others at level of duodenum. In 146 patients submitted to serial radiological investigations before surgery, the site of perforation was in 56 (38.3%) duodenal, in 52 (35.6%) juxta-pyloric, in 28 (19.1%) gastric and in 10 (6.8%) pyloric. The cause of perforation was in all cases gastric or duodenal ulceration, in seven cases involving pancreatic parenchyma. In 110 (75.4%) patients with direct findings of perforation, in 94 cases (85.5%) the correct diagnosis was established on abdominal plain film, in two (1.8%) with radiographic and sonographic examinations and in 14 (12.7%) on CT findings. In 36 (24,6%) patients with no direct findings of perforation, only 24

  20. An algorithm for intelligent sorting of CT-related dose parameters

    Science.gov (United States)

    Cook, Tessa S.; Zimmerman, Stefan L.; Steingal, Scott; Boonn, William W.; Kim, Woojin

    2011-03-01

    Imaging centers nationwide are seeking innovative means to record and monitor CT-related radiation dose in light of multiple instances of patient over-exposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose-length product (DLP)-an indirect estimate of radiation dose-requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, Arterial could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired, and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  1. An algorithm for intelligent sorting of CT-related dose parameters.

    Science.gov (United States)

    Cook, Tessa S; Zimmerman, Stefan L; Steingall, Scott R; Boonn, William W; Kim, Woojin

    2012-02-01

    Imaging centers nationwide are seeking innovative means to record and monitor computed tomography (CT)-related radiation dose in light of multiple instances of patient overexposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival, and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose length product (DLP)--an indirect estimate of radiation dose--requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, "arterial" could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  2. Imaging of adrenal disorders

    International Nuclear Information System (INIS)

    Fukuchi, Soitsu

    1982-01-01

    Adrenal scintillation scanning, CT and ultrasonography are compared with the conventional imaging methods. The accuracy of retroperitoneal pneumography and adrenal venography are not high, and they detected only large tumors such as Cushing's syndrome and pheochromocytoma. Scintillation scanning is highly effective for the diagnoses of primary aldosteronism and Cushing's syndrome. However, this technique does not visualize pheochromocytoma or hypopituitarism. CT is noninvasive and of high diagnostic value. It is impossible to diagnose tumors by ultrasonography unless the size is more than 3 cm. (Chiba, N.)

  3. Radioisotopic phlebography in investigating venous diseases of lower limbs

    International Nuclear Information System (INIS)

    San-Galli, F.; Vendaud-Busquet, M.; Philippe, J.C; Leccia, F.; Beylot, C.; Ducassous, D.

    1984-01-01

    The aim of this study is to analyse the interest of isotope phlebography in diagnosis of deep thrombosis and of chronic venous disease in the lower extremity as well as its value in relation to contrast venography. Out of 30 patients, 17 underwent both examinations. With contrast venography as a means of testing, radioisotope phlebography has a sensitivity of 71%, a specificity of 100%, an accuracy of 88%. Thirteen patients only had isotope phlebography. Results were confirmed everybody by clinical developments. The main interest of isotope phlebography is the diagnosis of femoral and iliac thromboses with a sensitivity and specificity of 100% at this point. In chronic venous disease isotope phlebography only shows indirect signs but gives information on the permeability of deep veins, wich is enough to make a therapeutic decision [fr

  4. Radioisotopic phlebography in investigating venous diseases of lower limbs

    Energy Technology Data Exchange (ETDEWEB)

    San-Galli, F.; Vendaud-Busquet, M.; Philippe, J.C; Leccia, F.; Beylot, C.; Ducassous, D. (Hopital du Haut-Leveque, 33 - Pessac (France))

    1984-10-01

    The aim of this study is to analyse the interest of isotope phlebography in diagnosis of deep thrombosis and of chronic venous disease in the lower extremity as well as its value in relation to contrast venography. Out of 30 patients, 17 underwent both examinations. With contrast venography as a means of testing, radioisotope phlebography has a sensitivity of 71%, a specificity of 100%, an accuracy of 88%. Thirteen patients only had isotope phlebography. Results were confirmed everybody by clinical developments. The main interest of isotope phlebography is the diagnosis of femoral and iliac thromboses with a sensitivity and specificity of 100% at this point. In chronic venous disease isotope phlebography only shows indirect signs but gives information on the permeability of deep veins, which is enough to make a therapeutic decision.

  5. Relevance of CT and MRI in retinoblastoma for the diagnosis of postlaminar invasion with normal-size optic nerve: a retrospective study of 150 patients with histological comparison

    International Nuclear Information System (INIS)

    Brisse, Herve J.; Guesmi, Myriam; Neuenschwander, Sylvia; Aerts, Isabelle; Sastre-Garau, Xavier; Savignoni, Alexia; Asselain, Bernard; Bours, Daniele; Lumbroso-Le Rouic, Livia; Desjardins, Laurence; Doz, Francois

    2007-01-01

    Detection of optic nerve invasion is mandatory in children primarily enucleated for retinoblastoma to ensure a free resection margin. To assess the accuracy of CT and MRI for the detection of postlaminar invasion in normal-size nerves. A total of 150 patients enucleated for retinoblastoma were included. Imaging data (119 CT and 46 MRI) were retrospectively reviewed and compared with histological findings. Abnormal contrast enhancement of the optic nerve was used as diagnostic criterion for invasion. The associations between postlaminar invasion and several indirect signs were also assessed. Statistical analysis was performed with the Kruskal-Wallis and Fisher exact tests. Postlaminar invasion on histology was observed in 8% (12/150). The sensitivity, specificity, accuracy and negative and positive predictive values were 60%, 95%, 91%, 95% and 60% for MRI, and 0%, 100%, 94% and 94% (PPV not assessable) for CT, respectively. Tumour diameter was the only indirect radiological sign significantly associated with postlaminar optic nerve invasion (P=0.002). Our results suggest that MRI is more relevant than CT for preoperative detection of optic nerve invasion in patients with retinoblastoma. Tumour diameter is the only indirect sign significantly associated with postlaminar invasion. (orig.)

  6. Relevance of CT and MRI in retinoblastoma for the diagnosis of postlaminar invasion with normal-size optic nerve: a retrospective study of 150 patients with histological comparison

    Energy Technology Data Exchange (ETDEWEB)

    Brisse, Herve J.; Guesmi, Myriam; Neuenschwander, Sylvia [Institute Curie, Department of Radiology, Paris (France); Aerts, Isabelle [Institute Curie, Department of Paediatric Oncology, Paris (France); Sastre-Garau, Xavier [Institute Curie, Department of Pathology, Paris (France); Savignoni, Alexia; Asselain, Bernard; Bours, Daniele [Institute Curie, Department of Biostatistics, Paris (France); Lumbroso-Le Rouic, Livia; Desjardins, Laurence [Institute Curie, Department of Ocular Oncology, Paris (France); Doz, Francois [Institute Curie, Department of Paediatric Oncology, Paris (France); Faculty of Medicine, Department of Paediatrics, Paris (France)

    2007-07-15

    Detection of optic nerve invasion is mandatory in children primarily enucleated for retinoblastoma to ensure a free resection margin. To assess the accuracy of CT and MRI for the detection of postlaminar invasion in normal-size nerves. A total of 150 patients enucleated for retinoblastoma were included. Imaging data (119 CT and 46 MRI) were retrospectively reviewed and compared with histological findings. Abnormal contrast enhancement of the optic nerve was used as diagnostic criterion for invasion. The associations between postlaminar invasion and several indirect signs were also assessed. Statistical analysis was performed with the Kruskal-Wallis and Fisher exact tests. Postlaminar invasion on histology was observed in 8% (12/150). The sensitivity, specificity, accuracy and negative and positive predictive values were 60%, 95%, 91%, 95% and 60% for MRI, and 0%, 100%, 94% and 94% (PPV not assessable) for CT, respectively. Tumour diameter was the only indirect radiological sign significantly associated with postlaminar optic nerve invasion (P=0.002). Our results suggest that MRI is more relevant than CT for preoperative detection of optic nerve invasion in patients with retinoblastoma. Tumour diameter is the only indirect sign significantly associated with postlaminar invasion. (orig.)

  7. CT findings of lumbar intervertebral disc: II. Disc herniation (HNP)

    International Nuclear Information System (INIS)

    Yang, W. J.; Lee, J. M.; Bahk, Y. W.

    1984-01-01

    In lumbar region the epidural fat pad is relatively abundant so that CT can provides sufficient information in diagnosis of lumbar HNP. Many authors have reported on the CT findings of HNP such as focal nodular protrusion of the posterior disc margin, obliteration of epidural fat pad, impingement of dural sac and nerve root, swelling of nerve root, soft tissue density in the spinal canal and calcification of disc. However there was so previous report describing incidence and reliability of the findings. It is the purpose of the present study to survey the frequency, reliability, and limitation of these CT findings. The clinical material was consisted of 30 operatively proven cases of HNP of the lumbar spine. Each lumbar CT scan was reviewed retrospectively and the findings were analysed by two radiologists independently. There were 20 males and 10 females and the mean age was 36.7 years. Involvement of L4-S5 level was 2.3 times more frequent than that of L5-S1 level. Of 30 cases, 22 were unilateral posterolateral types and 8 cases central or unilateral far lateral types. CT findings observed were nodular protrusion of the posterior margin of the disc, obliteration of epidural fat pad, impingement of dural sac or nerve root, soft tissue density in the spinal canal and calcification in the posterior portion of the protruded disc, in order of decreasing frequency. The conclusions are follows: 1. Nodular protrusion of the posterior disc margin accompanied by obliteration of epidural fat pad was observed in every case. The former findings was designated as direct sign and the latter indirect. 2. Obliteration of the epidural fat appears to be significant in lateral recesses especially when it occurs unilaterally. This was not true, however, in the centrally located fat pad. 3. Impingement of the dural sac and nerve root were observed in 90% and 67%, respectively, and were very helpful in establishing HNP diagnosis when the direct and indirect signs were equivocal

  8. A performance comparison of direct- and indirect-detection flat-panel imagers

    International Nuclear Information System (INIS)

    Partridge, M.; Hesse, B.-M.; Mueller, L.

    2002-01-01

    A comparison of the performance of a direct- and an indirect-detection amorphous silicon flat-panel X-ray imager is presented for a 6 MV beam. Experimental measurements of the noise characteristics, image lag, spectral response, spatial resolution and quantum efficiency are described, compared and discussed. The two systems are comprised of 512x512 pixel, 400 μm pitch, arrays of a-Si:H p-i-n photodiodes and thin-film transistors. In the direct-detection system, X-rays interact to produce electron/hole pairs directly in the silicon photodiodes. For the indirect-detection system, a phosphor screen converts energy from the incident X-rays into visible light, which is then detected by the photodiodes. Both systems are shown to be quantum noise limited, with the total electronic noise in the detector 10-15 times smaller than the Poisson noise level in detected signal. The measured lag for both systems is 1.0±0.1% or less in the first frame with subsequent signals decaying exponentially with frame read-out, with a half-life of between 3.3 and 3.8 frames. Both systems are demonstrated to have a pronounced sensitivity to low-energy multiply scattered photons, although this is shown to be effectively filtered out using a 2 mm copper build-up plate. The direct-detection system, with the 2 mm Cu build-up, shows greater sensitivity to scattered radiation than the indirect system. The spatial resolutions of both systems were effectively equal with an f 50 of 0.25 mm -1 when pixels are binned 2x2, although a slight contribution from optical scattering in the phosphor screen is seen for the indirect-detection system. The quantum efficiency of the direct-detection system is a factor of 0.45 lower than that of the indirect-detection system. The application of these detectors to megavoltage CT is discussed, with the conclusion that the indirect-detection system is to be preferred

  9. CT and US findings of ovarian torsion within an incarcerated inguinal hernia.

    Science.gov (United States)

    Hyun, Park Mee; Jung, Ah Young; Lee, Yul; Yang, Ik; Yang, Dae Hyun; Hwang, Ji-Young

    2015-02-01

    Inguinal hernia is relatively common in children. Although inguinal hernia is not frequently encountered in girls in comparison to boys, there are occasional cases of uterine or ovarian herniation in female indirect inguinal hernia. Incarcerated ovary in hernia sac has the risk of torsion and strangulation. We present an 8-year-old girl with painful mass in her left groin. With computed tomography (CT) and ultrasonography (US), we made the diagnosis of ovarian strangulation within an incarcerated inguinal hernia. Since ultrasound is primarily used for evaluation of groin mass, CT findings of an incarcerated inguinal hernia is rarely reported.

  10. The comparative study of lumbar disc disruption with MRI and CT discography

    International Nuclear Information System (INIS)

    Chen Xingcan; Liu Naifang; Li Xiaohong; Xu Wengen; Zou Qing; Yang Yonghong

    2005-01-01

    Objective: To compare MRI with CT discography (CTD) for diagnostic assessment of lumbar disc disruption. Methods: Paired comparative examination in 16 patients with chronic lower back pain without radicular pain and no disc herniation was conducted using CT or MRI. The standard of CTD classification and positive disc was formulated and the correlation between the induced lower back pain and dosage used in CTD was observed. Results: For a total of 21 discs in the 16 patients, CTD showed the disc as type 2 in 12 discs and type 5 in 1 disc with 13 positive discs, while MRI only showed the high-intensity zone of posterior annulus in 6 discs as the indirect sign of disc disruption and disc degeneration in 7 discs. Conclusion: CTD was the only method for showing the direct sign of disc disruption. The induced lower back pain was related with the type of disc disruption. MRI can show some of the indirect signs of disc disruption and CTD can show the direct sign of disc disruption. (authors)

  11. Indirection and computer security.

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Michael J.

    2011-09-01

    The discipline of computer science is built on indirection. David Wheeler famously said, 'All problems in computer science can be solved by another layer of indirection. But that usually will create another problem'. We propose that every computer security vulnerability is yet another problem created by the indirections in system designs and that focusing on the indirections involved is a better way to design, evaluate, and compare security solutions. We are not proposing that indirection be avoided when solving problems, but that understanding the relationships between indirections and vulnerabilities is key to securing computer systems. Using this perspective, we analyze common vulnerabilities that plague our computer systems, consider the effectiveness of currently available security solutions, and propose several new security solutions.

  12. Desfechos clínicos após investigação para Embolia Pulmonar utilizando TC de tórax/membros inferiores Clinical outcomes after investigation for pulmonary embolism using CT angiography and venography

    Directory of Open Access Journals (Sweden)

    Eduardo S. Darze

    2012-08-01

    assess clinical outcomes after a negative investigation using a combined protocol of CT pulmonary angiography and CT venography (CTA/CTV as a sole diagnostic test in unselected patients with suspected PE. METHODS: This retrospective cohort study enrolled consecutive patients with suspected PE who were investigated with a combined CTA/CTV protocol. Patients who had an initially negative investigation and were not anticoagulated were followed for 6 months for the occurrence of recurrent venous thromboembolic events. RESULTS: Out of 425 patients with suspected PE, 62 (14.6% had venous thromboembolism diagnosed on the initial CTA/CTV. The mean age was 56 ± 19 years and 61% of the population fell into the low clinical probability category. Isolated deep vein thrombosis represented 21% of all venous thromboembolic events, and when considering the whole population, CTV was associated with an increment in diagnostic yield of 3.1%. Our cohort was composed of 320 patients with initially negative CTA/CTVs and who were not anticoagulated. After 6 months of follow up, only three patients presented with recurrent thromboembolic events (0.9%; 95% CI -0.1% - 2.0% and none was fatal. There were no PE-related deaths. CONCLUSION: Our study suggests that a diagnostic strategy that utilizes CTA/CTV as a sole diagnostic test can safely rule out PE in a low to moderate risk population and is associated with favorable outcomes with a negative predictive value of 99.1%. (Arq Bras Cardiol. 2012; [online].ahead print, PP.0-0

  13. Diagnosis of acute flank pain caused by ureteral stones: value of combined direct and indirect signs on IVU and unenhanced helical CT

    International Nuclear Information System (INIS)

    Wang, Li-Jen; Wong, Yon-Cheong; Ng, Chip-Jin; Chen, Jih-Chang; Chiu, Te-Fa

    2004-01-01

    The aim of this study was to assess the usefulness of combined direct and indirect signs on intravenous urography (IVU) and unenhanced helical computed tomography (UHCT) for the diagnosis of ureteral stones in emergency patients with acute flank pain. During an 8-month period, 82 emergency patients with acute flank pain undergoing IVU and UHCT with sufficient clinical follow-up formed the study group. The presence or absence of direct sign (visualization of ureteral stones) and indirect signs on IVU and UHCT was recorded. The diagnostic accuracy of each direct/indirect sign and their combination for the diagnosis of ureteral stones on IVU and UHCT were analyzed and compared. Of the 82 patients, 66 had ureteral stones, four had passed urinary stones prior to imaging and 12 had other diseases. The diagnostic accuracies of direct signs on IVU and UHCT for the diagnosis of ureteral stones were 79.3 and 98.8%, respectively, which was more accurate than that of any single indirect sign on IVU and UHCT. However, the diagnostic accuracy of ureteral stones by IVU increased to 90.2% when using diagnostic criteria requiring the presence of a direct sign or at least three indirect signs, and by UHCT, it increased to 100% when using diagnostic criteria requiring the presence of a direct sign with at least one indirect sign. Therefore, for emergency patients with acute flank pain, the use of the above combinations of direct/indirect signs is useful as the diagnostic criterion for ureteral stones. (orig.)

  14. Blunt traumatic rupture of a mainstem bronchus: spiral CT demonstration of the ''fallen lung'' sign

    International Nuclear Information System (INIS)

    Wintermark, M.; Schnyder, P.; Wicky, S.

    2001-01-01

    Tracheo-bronchial injuries occur in less than 1 % of blunt chest trauma patients. Indirect signs, such as pneumomediastinum, pneumothorax, and/or subcutaneous emphysema, are revealed on admission plain films and chest CT survey. In most instances, however, tracheo-bronchoscopy is mandatory in assessing the definite diagnosis of tracheo-bronchial lesion. Occasionally, an abnormal course of a mainstem bronchus or a ''fallen lung'' sign, featuring a collapsed lung in a dependent position, hanging on the hilum only by its vascular attachments, may allow for CT diagnosis of a blunt traumatic bronchial injury. (orig.)

  15. Percutaneous vertebroplasty for osteoporotic vertebral compression fractures with intraosseous cystic cavity phenomena

    International Nuclear Information System (INIS)

    He Shicheng; Teng Gaojun; Deng Gang; Fang Wen; Guo Jinhe; Zhu Guangyu; Li Guozao; Shen Zhiping; Ding Huijuan

    2005-01-01

    Objective: To evaluate the key technique, short term clinical efficacy and degree of changes in vertebral body height for percutaneous vertebroplasty in treating patients with osteoporotic vertebral compression fractures containing intraosseous cystic cavity phenomena. Methods: Thirty two vertebrae of painful compression fractures with intraosseous vacuum sign occurring in 27 patients were identified from 326 percutaneous vertebroplasties performed in 207 patients during 4 years. PVP was performed under C-arm fluoroscopy guidance only with local anesthesia. Intaosseous venography was performed on each vertebra by hand injection with non-ionic contrast agent, with CT monitoring after PMMA injection for the PMMA distribution in the vertebrae and looking for leakage. The heights of 32 vertebral bodies were measured before and after the vertebroplasty. The efficacy of PVP was evaluated during the follow-up. Results: The successful rate of PVP was 100%. Main appearance of vertebral venography showed cystic cavity-like, stasis of contrast medium within the marrow space of the fractured vertebra. 6.8 ml of PMMA in average was injected into each vertebra. CR, PR and NR were obtained respectively 66.7%, 18.5%, 14.8% mm centrally and 0.06 mm posteriorly. The heights restoration of vertebrae anteriorly and centrally were significantly different (P 0.05). No serious complications related to the technique occurred, except 3 cases with asymptomatic PMMA leakage around vertebrae demonstrated by CT. Conclusions: Significant pain relief and vertebral height restoration by PVP in the treatment of patients with painful vertebral compression fractures accompanied by intraosseous cysticavitary change, are promising with low-rate of PMMA leakage. The basic successful mechanism lies on the proper complete PMMA filling predicting through venography. (authors)

  16. Imaging of bridging vein thrombosis in infants with abusive head trauma: the ''Tadpole Sign''

    Energy Technology Data Exchange (ETDEWEB)

    Hahnemann, Maria L.; Kinner, Sonja; Schweiger, Bernd [University Hospital Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Bajanowski, Thomas [University Hospital Essen, Institute of Legal Medicine, Essen (Germany); Karger, Bernd; Pfeiffer, Heidi; Wittschieber, Daniel [University Hospital Muenster, Institute of Legal Medicine, Muenster (Germany)

    2014-10-03

    Abusive head trauma (AHT) in infants is usually diagnosed using a multi-disciplinary approach by investigating the circumstances and identifying morphological indicators, for example, subdural hematomas (SDHs), subdural hygromas (SDHys), retinal haemorrhages and encephalopathy. The present morphological study investigates the incidence, radiological characteristics and non-radiological co-factors of bridging vein thrombosis (BVT) in infants with AHT. From 2002 to 2013, computed tomography (CT) and magnetic resonance imaging (MRI) material of 628 infants aged 0-2 years were analysed retrospectively. If available, medicolegal expert opinions were additionally considered. Cases with SDHs and/or SDHys were identified and systematically evaluated as to the presence and characteristics of BVT. SDHs and/or SDHys were present in 29 of the 81 cases exhibiting morphological abnormalities in the initial CT. Among these, 11 cases (40 %) had BVT (mean age = 5.0 months). BVT could be best depicted in the T1-weighted spin echo and T2*/susceptibility-weighted MRI. In one case, BVT could be depicted indirectly using time-of-flight MR venography. The predominant (73 %) BVT shape was found to be tadpole-like (''Tadpole Sign''). In the absence of appropriate accidental trauma, BVT appears to be a strong indicator of AHT. Therefore, the BVT/Tadpole Sign represents compelling cause to search for other signs of AHT. (orig.)

  17. Thin-section CT of Cushing's disease

    International Nuclear Information System (INIS)

    Takahashi, Tatsuo; Kuwayama, Akio; Katoh, Tetsuo; Ichihara, Kaoru; Kageyama, Naoki; Nakamura, Koji.

    1983-01-01

    Using 1.5 mm contiguous sections with a GE CT/T 8800 scanner, we investigated the sellar regions of 22 cases of Cushing's diseases which had been diagnosed endocrinologically. Each sellar turcica was normal in size, and in only 5 cases were there significant findings on 2 mm-thick sellar-floor polytomography. Nine tumors appeared as regions of a hypodense area, and three tumors were diagnosed by indirect signs, for example, stalk deviation and diaphragmatic plane asymmetry. The other 10 cases, especially those previously operated on or irradiated, were diagnosed as falsely positive or negative. Because it is best of the microadenomas appear hypodense within the strongly contrast-enhanced anterior pituitary glands, it is better for scans to be obtained immediately after rapid intravenous contrast infusion. Hypodense areas of microadenomas are best demonstrated on direct coronal scans or reversed scans of 1.5 mm-thickness thin-slice sections. By these methods, microadenomas, if they are over 5-6 mm in diameter, can appear as hypodense. Sellar floor findings by means of thin-section CT were more sensitive than those of polytomography and had more advantages in local diagnosis. If the tumor were over 4 mm in diameter, local changes in the sellar floor could be demonstrated by thin-section CT, but by polytomography no changes in the sellar floor could be demonstrated until the tumor size reached 6 mm. (author)

  18. Comparison of imaging properties of direct-type and indirect-type of flat-panel detector

    International Nuclear Information System (INIS)

    Matsumoto, Masao; Suekane, Koji; Ichimaru, Yasunobu; Ogata, Yuji; Inamura, Kiyonari; Kanai, Kouzou; Kanamori, Hitoshi

    2002-01-01

    A Flat-Panel Detector (FPD) has many advantages such as eliminating cassette handling and being able to display a preview image immediately in addition to the digital image processing and the networking. Thus, the FPD has ability to innovate the radiology department. We measured and evaluated the digital and over-all imaging properties (characteristic curves, modulation Transfer Functions, Wiener spectra and Noise Equivalent Quanta (NEQ) for the direct-type and indirect-type of FPD. The pre-sampling and overall NEQ of the indirect-type of FPD were better than the NEQ of the direct-type of FPD at lower spatial frequencies, but were worse at higher spatial frequencies. The FPD can take image data at real-time and be easy to digitalize. From these results, Screen/Film system and Computed Radiography system will be replaced by the FPD system, together with diffusion of CAD, cone beam Computed Tomography (CT) system and open-type Magnetic Resonance Imagining (MRI) system. (T. Tanaka)

  19. Budd-Chiari syndrome: CT and MRI findings

    International Nuclear Information System (INIS)

    Xu Kai; Li Lingsun

    2008-01-01

    Budd-Chiari syndrome is an uncommon but often fatal disorder resulting from obstruction of hepatic venous outflow tract at the level of the hepatic veins, the inferior vena cava. The CT and MRI characteristics of Budd-Chiari syndrome are reviewed in this article especially for displaying the exact site and extent of the obstruction. In addition to this direct sign, the indirect findings of venous obstruction such as the presence of intra-and extrahepatic collateral veins, caudate lobe enlargement, inhomogeneous liver enhancement, and regenerative nodules can also be demonstrated. Awareness of these findings is important for early diagnosis and appropriate treatment. (authors)

  20. Cruel intentions on television and in real life: can viewing indirect aggression increase viewers' subsequent indirect aggression?

    Science.gov (United States)

    Coyne, Sarah M; Archer, John; Eslea, Mike

    2004-07-01

    Numerous studies have shown that viewing violence in the media can influence an individual's subsequent aggression, but none have examined the effect of viewing indirect aggression. This study examines the immediate effect of viewing indirect and direct aggression on subsequent indirect aggression among 199 children ages 11 to 14 years. They were shown an indirect, direct, or no-aggression video and their subsequent indirect aggression was measured by negative evaluation of a confederate and responses to a vignette. Participants viewing indirect or direct aggression gave a more negative evaluation of and less money to a confederate than participants viewing no-aggression. Participants viewing indirect aggression gave less money to the confederate than those viewing direct aggression. Participants viewing indirect aggression gave more indirectly aggressive responses to an ambiguous situation and participants viewing direct aggression gave more directly aggressive responses. This study provides the first evidence that viewing indirect aggression in the media can have an immediate impact on subsequent aggression.

  1. CT-guided cervical nerve root injections: comparing the immediate post-injection anesthetic-related effects of the transforaminal injection with a new indirect technique

    International Nuclear Information System (INIS)

    Sutter, Reto; Pfirrmann, Christian W.A.; Peterson, Cynthia K.; Zanetti, Marco; Hodler, Juerg

    2011-01-01

    To describe an ''indirect'' cervical nerve root injection technique with a dorsal approach that should carry less inherent risk than the ''direct'' cervical transforaminal injection approach, and to compare the immediate post-injection results of the two procedures. The indirect and direct cervical nerve root injection procedures are described in detail. Fifty-three consecutive patients receiving the indirect nerve root injections during 2009-2010 were age- and gender-matched to 53 patients who underwent direct transforaminal nerve root injections performed in 2006. Pain level data were collected immediately before and 20-30 min after each procedure. The percentages of pain change in the two groups were compared using the unpaired Student's t test. Fifty-two men (mean age 49) and 54 women (mean age 55) were included. The mean percentage of pain reduction for patients receiving indirect nerve root injections was 38.4% and for those undergoing the direct nerve root injections approach it was 43.2%. This was not significantly different (P = 0.455). No immediate or late adverse effects were reported after either injection procedure. The indirect cervical nerve root injection procedure is a potentially safer alternative to direct cervical transforaminal nerve root injections. The short-term pain reduction is similar using the two injection methods. (orig.)

  2. Deep Vein Thrombosis of the Left Leg: A Case of May-Thurner Syndrome

    Directory of Open Access Journals (Sweden)

    Jiten Desai

    2018-02-01

    Full Text Available A 56-year-old woman presented with gradually worsening shortness of breath associated with dull left leg pain over 5 days. She denied any recent travel, recent surgeries or immobilization. CT pulmonary angiography and CT venography revealed multiple bilateral pulmonary emboli and extensive left pelvic and left lower extremity deep vein thromboses. Contrast-enhanced CT showed that the right common iliac artery crossed the left common iliac vein and compressed it externally, indicative of May–Thurner syndrome. Catheter-directed thrombolysis of the left lower extremity was performed and heparin infusion was started. The patient also underwent left iliac vein balloon angioplasty with stenting and infra-renal inferior vena cava filter placement via the jugular approach to prevent further embolization.

  3. Micro-CT evaluation of microleakage under orthodontic ceramic brackets bonded with different bonding techniques and adhesives.

    Science.gov (United States)

    Öztürk, Fırat; Ersöz, Mustafa; Öztürk, Seyit Ahmet; Hatunoğlu, Erdem; Malkoç, Sıddık

    2016-04-01

    The aim of this study was to evaluate microleakage under orthodontic ceramic brackets bonded with direct and different indirect bonding techniques and adhesives using micro-computed tomography. A total of 30 human maxillary premolars were randomly separated into five groups with six teeth in each group. In group I, teeth were bonded directly with Transbond XT (3M Unitek). In group II, group III, group IV, and group V, teeth were bonded through an indirect technique with Custom I.Q. (Reliance Orthodontic Products), Sondhi Rapid-Set (3M Unitek), RMbond (RMO), and Transbond IDB (3M Unitek), respectively, following the manufacturer's instructions. Micro-CT system model 1172 of Skyscan (Kontich, Belgium) was used to scan all samples. NRecon (Skyscan) version 1.6, CT-Analyser V.1.11 (Skyscan), and TView (SkyScan, Bvba) software programs were used for microleakage evaluation. Microleakage values between the test groups were assessed using the Kruskal-Wallis test, while the Wilcoxon signed rank test was used for within-group comparisons. The level of significance was set at P Kruskal-Wallis analysis of variance test, there were no significant differences among the tested groups, with regard to volume and percentage (microleakage/region of interest × 100) of microleakage values (P test showed that coronal microleakage volume and percentage values significantly differed for RMbond and Transbond IDB groups. In the study, only ceramic brackets were used and microleakage into mini gaps did not show up on the micro-CT image because 50% silver nitrate solution could not penetrate into mini gaps which are smaller than silver nitrate particles. Use of direct and indirect bonding techniques with different adhesives did not significantly affect the amount of microleakage. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  4. Indirect taxation in the European Union

    OpenAIRE

    Ene, Sebastian; Micuda, Dan

    2007-01-01

    Indirect taxes are levied on the production and consumption of goods and services. They influence the retail price, and hence affect patterns of trade and consumption. Indirect taxes are ultimately paid by the final consumer. Sales and turnover taxes, excise duties and tariffs are the basic indirect taxes. In contrast with direct taxes, indirect taxes are seldom progressive. The principles for the levying of these taxes will be considered before the analysis of indirect taxes.

  5. CT studies of mesentery and related vascular findings in strangulating intestinal obstruction

    International Nuclear Information System (INIS)

    Li Wenhua; Cao Qingxuan; Yang Shifeng; Li Jianhai; Lu Shenglin; Zhang Qiang; Wu Tian

    2006-01-01

    Objective: To investigate the CT appearance of mesentery and related vascular (MRV) findings in strangulating obstruction (SO) and evaluate the value of CT examination for diagnosing SO. Methods: Thirty patients with SO were included in the investigation. The diagnosis was confirmed by operation in 26 cases and 4 cases by clinic. The cause of SO included adhesion in 9 cases, volvulus in 8 cases, intussusception in 6 cases, infarction of mesenteric vesseles in 4 cases, and internal hernia in 3 cases, respectively. All patients was examined with CT and 20 of them with enhanced CT. Results: Eleven items of CT findings were revealed in these patients. The findings could be divided into 3 types: (1) direct signs: including embolism of mesenteric vasculature in 2 cases and mesenteric edema and related vascular enlargement in 19 cases. (2)indirect signs: including bowel wall edema and thickenning in 24 cases, abnormal enhancement of the wall in 6 cases, massive fluid in the bowel in 13 cases, abnormal form of loops in 10 cases, and hemorrhage of bowel wall and mesentery in 1 case each. (3) complicated signs: including intramural gas in 3 cases, intrahepatic portal veins gas in 1 case, gas in mesentery in 1 case, and ascites and pneumoperitoneum in 11 cases. Conclusion: The CT findings of mesenteric edema, ischemia and infarction are reliable and characteristic signs for diagnosing SO. The diagnosis of SO can be correctly made before operation if these signs are recognized, at the same time, CT may demonstrate some complications which can not be revealed by traditional X-ray examinations. (authors)

  6. MCNPX simulation of proton dose distribution in homogeneous and CT phantoms

    International Nuclear Information System (INIS)

    Lee, C.C.; Lee, Y.J.; Tung, C.J.; Cheng, H.W.; Chao, T.C.

    2014-01-01

    A dose simulation system was constructed based on the MCNPX Monte Carlo package to simulate proton dose distribution in homogeneous and CT phantoms. Conversion from Hounsfield unit of a patient CT image set to material information necessary for Monte Carlo simulation is based on Schneider's approach. In order to validate this simulation system, inter-comparison of depth dose distributions among those obtained from the MCNPX, GEANT4 and FLUKA codes for a 160 MeV monoenergetic proton beam incident normally on the surface of a homogeneous water phantom was performed. For dose validation within the CT phantom, direct comparison with measurement is infeasible. Instead, this study took the approach to indirectly compare the 50% ranges (R 50% ) along the central axis by our system to the NIST CSDA ranges for beams with 160 and 115 MeV energies. Comparison result within the homogeneous phantom shows good agreement. Differences of simulated R 50% among the three codes are less than 1 mm. For results within the CT phantom, the MCNPX simulated water equivalent R eq,50% are compatible with the CSDA water equivalent ranges from the NIST database with differences of 0.7 and 4.1 mm for 160 and 115 MeV beams, respectively. - Highlights: ► Proton dose simulation based on the MCNPX 2.6.0 in homogeneous and CT phantoms. ► CT number (HU) conversion to electron density based on Schneider's approach. ► Good agreement among MCNPX, GEANT4 and FLUKA codes in a homogeneous water phantom. ► Water equivalent R 50 in CT phantoms are compatible to those of NIST database

  7. Risk-benefit analysis and cost-effectiveness analysis of lung cancer screening by spiral CT

    International Nuclear Information System (INIS)

    Iinuma, Takeshi

    1999-01-01

    Mass screening of lung cancer has been widely performed using indirect chest X-ray method in Japan. However reduction of the mortality for lung cancer is questioned. We have proposed that recently developed spiral CT should be adopted for the screening of lung cancer, since CT has an excellent detectability for small nodule. Lung Cancer Screening CT (LSCT) has been developed by author's group using spiral CT with low dose and light weight in order to make a mobile unit. In this paper risk-benefit analysis and cost-effectiveness analysis are described for the LSCT screening of lung cancer. As a risk, radiation carcinogenesis due to exposure from LSCT are compared with gain of life-expectancy by screening and men of 40 years or more and women of 45 years or more are justified. The cost per person-year is estimated for LSCT screening which is better than that of present method, although total cost is higher. The LSCT screening could be recommended if total cost is affordable. (author)

  8. Evaluation of a low-dose CT protocol with oral contrast for assessment of acute appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Platon, Alexandra; Jlassi, Helmi; Becker, Christoph D.; Poletti, Pierre-Alexandre [University Hospital of Geneva, Department of Radiology, Geneva 14 (Switzerland); Rutschmann, Olivier T. [University Hospital of Geneva, Emergency Center, Geneva (Switzerland); Verdun, Francis R. [University Institute for Radiation Physics, Lausanne (Switzerland); Gervaz, Pascal [University Hospital of Geneva, Clinic of Digestive Surgery, Geneva (Switzerland)

    2009-02-15

    The aim of this study was to evaluate a low-dose CT with oral contrast medium (LDCT) for the diagnosis of acute appendicitis and compare its performance with standard-dose i.v. contrast-enhanced CT (standard CT) according to patients' BMIs. Eighty-six consecutive patients admitted with suspicion of acute appendicitis underwent LDCT (30 mAs), followed by standard CT (180 mAs). Both examinations were reviewed by two experienced radiologists for direct and indirect signs of appendicitis. Clinical and surgical follow-up was considered as the reference standard. Appendicitis was confirmed by surgery in 37 (43%) of the 86 patients. Twenty-nine (34%) patients eventually had an alternative discharge diagnosis to explain their abdominal pain. Clinical and biological follow-up was uneventful in 20 (23%) patients. LDCT and standard CT had the same sensitivity (100%, 33/33) and specificity (98%, 45/46) to diagnose appendicitis in patients with a body mass index (BMI) {>=} 18.5. In slim patients (BMI < 18.5), sensitivity to diagnose appendicitis was 50% (2/4) for LDCT and 100% (4/4) for standard CT, while specificity was identical for both techniques (67%, 2/3). LDCT may play a role in the diagnostic workup of patients with a BMI {>=} 18.5. (orig.)

  9. Evaluation of a low-dose CT protocol with oral contrast for assessment of acute appendicitis

    International Nuclear Information System (INIS)

    Platon, Alexandra; Jlassi, Helmi; Becker, Christoph D.; Poletti, Pierre-Alexandre; Rutschmann, Olivier T.; Verdun, Francis R.; Gervaz, Pascal

    2009-01-01

    The aim of this study was to evaluate a low-dose CT with oral contrast medium (LDCT) for the diagnosis of acute appendicitis and compare its performance with standard-dose i.v. contrast-enhanced CT (standard CT) according to patients' BMIs. Eighty-six consecutive patients admitted with suspicion of acute appendicitis underwent LDCT (30 mAs), followed by standard CT (180 mAs). Both examinations were reviewed by two experienced radiologists for direct and indirect signs of appendicitis. Clinical and surgical follow-up was considered as the reference standard. Appendicitis was confirmed by surgery in 37 (43%) of the 86 patients. Twenty-nine (34%) patients eventually had an alternative discharge diagnosis to explain their abdominal pain. Clinical and biological follow-up was uneventful in 20 (23%) patients. LDCT and standard CT had the same sensitivity (100%, 33/33) and specificity (98%, 45/46) to diagnose appendicitis in patients with a body mass index (BMI) ≥ 18.5. In slim patients (BMI < 18.5), sensitivity to diagnose appendicitis was 50% (2/4) for LDCT and 100% (4/4) for standard CT, while specificity was identical for both techniques (67%, 2/3). LDCT may play a role in the diagnostic workup of patients with a BMI ≥ 18.5. (orig.)

  10. Color Doppler US of normal cerebral venous sinuses in neonates: a comparison with MR venography

    International Nuclear Information System (INIS)

    Miller, Elka; Daneman, Alan; Doria, Andrea S.; Blaser, Susan; Traubici, Jeffrey; Jarrin, Jose; Shroff, Manohar; Moineddin, Rahim; Moore, Aideen

    2012-01-01

    Color Doppler US (CDUS) has been used for evaluation of cerebral venous sinuses in neonates. However, there is very limited information available regarding the appearance of superficial and deep normal cerebral venous sinuses using CDUS and the specificity of the technique to rule out disease. To determine the specificity, inter-modality and inter-reader agreement of color Doppler US (CDUS). To evaluate normal cerebral venous sinuses in neonates in comparison to MR venography (MRV). Newborns undergoing a clinically indicated brain MRI were prospectively evaluated. All underwent a dedicated CDUS of the cerebral venous sinuses within 10 h (mean, 3.5 h, range, and 2-7.6 h) of the MRI study using a standard protocol. Fifty consecutive neonates participated in the study (30 males [60%]; 25-41 weeks old; mean, 37 weeks). The mean time interval between the date of birth and the CDUS study was 19.1 days. No cases showed evidence of thrombosis. Overall agreement for US reading was 97% (range, 82-100%), for MRV reading, 99% (range, 96-100%) and for intermodality, 100% (range, 96-100%). Excellent US-MRI agreement was noted for superior sagittal sinus, cerebral veins, straight sinus, torcular Herophili, sigmoid sinus, superior jugular veins (94-98%) and transverse sinuses (82-86%). In 10 cases (20%), MRV showed flow gaps whereas normal flow was demonstrated with US. Visualization of the inferior sagittal sinus was limited with both imaging techniques. Excellent reading agreement was noted for US, MRV and intermodality. CDUS is highly specific to rule out cerebral venous thrombosis in neonates and holds potential for clinical application as part of clinical-laboratory-imaging algorithms of pre/post-test probabilities of disease. (orig.)

  11. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  12. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  13. Vascular Complications of Intercavernous Sinuses during Transsphenoidal Surgery: An Anatomical Analysis Based on Autopsy and Magnetic Resonance Venography.

    Science.gov (United States)

    Deng, Xuefei; Chen, Shijun; Bai, Ya; Song, Wen; Chen, Yongchao; Li, Dongxue; Han, Hui; Liu, Bin

    2015-01-01

    Vascular complications induced by intercavernous sinus injury during dural opening in the transsphenoidal surgery may contribute to incomplete tumour resections. Preoperative neuro-imaging is of crucial importance in planning surgical approach. The aim of this study is to correlate the microanatomy of intercavernous sinuses with its contrast-enhanced magnetic resonance venography (CE-MRV). Eighteen human adult cadavers and 24 patients were examined based on autopsy and CE-MRV. Through dissection of the cadavers and CE-MRV, the location, shape, number, diameter and type of intercavernous sinuses were measured and compared. Different intercavernous sinuses were identified by their location and shape in all the cadavers and CE-MRV. Compared to the cadavers, CE-MRV revealed 37% of the anterior intercavernous sinus, 48% of the inferior intercavernous sinus, 30% of the posterior intercavernous sinus, 30% of the dorsum sellae sinus and 100% of the basilar sinus. The smaller intercavernous sinuses were not seen in the neuro-images. According to the presence of the anterior and inferior intercavernous sinus, four types of the intercavernous sinuses were identified in cadavers and CE-MRV, and the corresponding operative space in the transsphenoidal surgical approach was implemented. The morphology and classification of the cavernous sinus can be identified by CE-MRV, especially for the larger vessels, which cause bleeding more easily. Therefore, CE-MRV provides a reliable measure for individualized preoperative planning during transsphenoidal surgery.

  14. Role of contrast-enhanced MR venography in the preoperative evaluation of parasagittal meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Bozzao, Alessandro; Finocchi, Vanina; Romano, Andrea; Ferrante, Michele; Fasoli, Fabrizio; Fantozzi, Luigi Maria [S. Andrea Hospital, Neuroradiological Section, Rome (Italy); Trillo, Giuseppe; Ferrante, Luigi [S. Andrea Hospital, Neurosurgical Section, Rome (Italy)

    2005-09-01

    Parasagittal meningiomas (PSM) may pose a difficult surgical challenge since venous patency and collateral anastomoses have to be clearly defined for correct surgical planning. The aim of this study was to assess the diagnostic value of contrast-enhanced (CE) magnetic resonance venography (MRV) in the preoperative evaluation of venous infiltration and collateral venous anastomoses in patients with PSM. CE-MRV was compared with phase-contrast (PC) magnetic resonance (MR) angiography, conventional angiography (when available), and surgery as a reference. Twenty-three patients undergoing surgery for meningiomas located adjacent to the superior sagittal sinus were prospectively evaluated. All the patients underwent both conventional MR examination and MRV. This was performed by means of PC and CE techniques. Both sets of angiograms (CE and PC) were evaluated by two expert neuroradiologists to assess (1) patency of the sinus (patent/occluded), (2) the extent of occlusion (in centimeters), and (3) the number of collateral anastomoses close to the insertion of the meningioma. Eight patients underwent digital subtraction angiography (DSA). All patients were operated on, and intraoperative findings were taken as the gold standard to evaluate the diagnostic value of MRA techniques. PC-MRV showed a flow void inside the sinus compatible with its occlusion in 15 cases, whereas CE-MRV showed the sinus to be occluded in five cases. CE-MRV data were confirmed by surgery, showing five patients to have an occlusion of the superior sagittal sinus. The PC-MRV sensitivity was thus 100% with a specificity of 50%. In those cases in which both MRV techniques documented occlusion of the sinus, the extent of occlusion was overestimated by PC compared with CE and surgery. CE-MRV depicted 87% of collateral venous anastomoses close to the meningioma as subsequently confirmed by surgery, while PC showed 58%. In the preoperative planning for patients with meningiomas located close to a venous

  15. Role of contrast-enhanced MR venography in the preoperative evaluation of parasagittal meningiomas

    International Nuclear Information System (INIS)

    Bozzao, Alessandro; Finocchi, Vanina; Romano, Andrea; Ferrante, Michele; Fasoli, Fabrizio; Fantozzi, Luigi Maria; Trillo, Giuseppe; Ferrante, Luigi

    2005-01-01

    Parasagittal meningiomas (PSM) may pose a difficult surgical challenge since venous patency and collateral anastomoses have to be clearly defined for correct surgical planning. The aim of this study was to assess the diagnostic value of contrast-enhanced (CE) magnetic resonance venography (MRV) in the preoperative evaluation of venous infiltration and collateral venous anastomoses in patients with PSM. CE-MRV was compared with phase-contrast (PC) magnetic resonance (MR) angiography, conventional angiography (when available), and surgery as a reference. Twenty-three patients undergoing surgery for meningiomas located adjacent to the superior sagittal sinus were prospectively evaluated. All the patients underwent both conventional MR examination and MRV. This was performed by means of PC and CE techniques. Both sets of angiograms (CE and PC) were evaluated by two expert neuroradiologists to assess (1) patency of the sinus (patent/occluded), (2) the extent of occlusion (in centimeters), and (3) the number of collateral anastomoses close to the insertion of the meningioma. Eight patients underwent digital subtraction angiography (DSA). All patients were operated on, and intraoperative findings were taken as the gold standard to evaluate the diagnostic value of MRA techniques. PC-MRV showed a flow void inside the sinus compatible with its occlusion in 15 cases, whereas CE-MRV showed the sinus to be occluded in five cases. CE-MRV data were confirmed by surgery, showing five patients to have an occlusion of the superior sagittal sinus. The PC-MRV sensitivity was thus 100% with a specificity of 50%. In those cases in which both MRV techniques documented occlusion of the sinus, the extent of occlusion was overestimated by PC compared with CE and surgery. CE-MRV depicted 87% of collateral venous anastomoses close to the meningioma as subsequently confirmed by surgery, while PC showed 58%. In the preoperative planning for patients with meningiomas located close to a venous

  16. Indirect Self-Destructiveness and Emotional Intelligence.

    Science.gov (United States)

    Tsirigotis, Konstantinos

    2016-06-01

    While emotional intelligence may have a favourable influence on the life and psychological and social functioning of the individual, indirect self-destructiveness exerts a rather negative influence. The aim of this study has been to explore possible relations between indirect self-destructiveness and emotional intelligence. A population of 260 individuals (130 females and 130 males) aged 20-30 (mean age of 24.5) was studied by using the Polish version of the chronic self-destructiveness scale and INTE, i.e., the Polish version of the assessing emotions scale. Indirect self-destructiveness has significant correlations with all variables of INTE (overall score, factor I, factor II), and these correlations are negative. The intensity of indirect self-destructiveness differentiates significantly the height of the emotional intelligence and vice versa: the height of the emotional intelligence differentiates significantly the intensity of indirect self-destructiveness. Indirect self-destructiveness has negative correlations with emotional intelligence as well as its components: the ability to recognize emotions and the ability to utilize emotions. The height of emotional intelligence differentiates the intensity of indirect self-destructiveness, and vice versa: the intensity of indirect self-destructiveness differentiates the height of emotional intelligence. It seems advisable to use emotional intelligence in the prophylactic and therapeutic work with persons with various types of disorders, especially with the syndrome of indirect self-destructiveness.

  17. Chronic thromboembolic pulmonary hypertension: Evaluation with 64-detector row CT versus digital substraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Reichelt, Angela [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Str. 1, 30625 Hannover (Germany)], E-mail: Reichelt.Angela@mh-hannover.de; Hoeper, Marius M. [Department of Respiratory Medicine, Hannover Medical School (Germany); Galanski, Michael [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Str. 1, 30625 Hannover (Germany); Keberle, Marc [Department of Diagnostic Radiology and Nuclear Medicine, Bruederkrankenhaus St. Josef Paderborn (Germany)

    2009-07-15

    The aim of the study was to evaluate the role of 64-row CT in the diagnostic workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH) using digital substraction angiography (DSA) as the method of diagnostic reference. CT and DSA studies of 27 patients (54 main, 162 lobar and 540 segmental arteries) with a clinical suspicion of CTEPH were included in this retrospective and blinded analysis. Axial images and multiplanar thin maximum intensity projections (MIPs) (3 mm) were consequently used for exact image interpretation whereas additional reconstructed thick MIPs gave an overview of the entire vascular tree comparable to DSA. Sensitivity and specificity of CT regarding CTEPH-related pathological changes in general were 98.3% and 94.8% at main/lobar level and 94.1% and 92.9% at segmental level, respectively. Sensitivity and specificity of CT regarding the different pathological criteria of CTEPH (complete obstruction, intimal irregularities, bands and webs, indirect signs) were 88.9-100% and 96.1-100% at main/lobar level and 84.3-90.5% and 92-98.7% at segmental level, respectively. Our results show that CT is an accurate and reliable non-invasive alternative to conventional DSA in the diagnostic workup in patients with CTEPH.

  18. Chronic thromboembolic pulmonary hypertension: Evaluation with 64-detector row CT versus digital substraction angiography

    International Nuclear Information System (INIS)

    Reichelt, Angela; Hoeper, Marius M.; Galanski, Michael; Keberle, Marc

    2009-01-01

    The aim of the study was to evaluate the role of 64-row CT in the diagnostic workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH) using digital substraction angiography (DSA) as the method of diagnostic reference. CT and DSA studies of 27 patients (54 main, 162 lobar and 540 segmental arteries) with a clinical suspicion of CTEPH were included in this retrospective and blinded analysis. Axial images and multiplanar thin maximum intensity projections (MIPs) (3 mm) were consequently used for exact image interpretation whereas additional reconstructed thick MIPs gave an overview of the entire vascular tree comparable to DSA. Sensitivity and specificity of CT regarding CTEPH-related pathological changes in general were 98.3% and 94.8% at main/lobar level and 94.1% and 92.9% at segmental level, respectively. Sensitivity and specificity of CT regarding the different pathological criteria of CTEPH (complete obstruction, intimal irregularities, bands and webs, indirect signs) were 88.9-100% and 96.1-100% at main/lobar level and 84.3-90.5% and 92-98.7% at segmental level, respectively. Our results show that CT is an accurate and reliable non-invasive alternative to conventional DSA in the diagnostic workup in patients with CTEPH.

  19. TU-AB-BRA-02: An Efficient Atlas-Based Synthetic CT Generation Method

    International Nuclear Information System (INIS)

    Han, X

    2016-01-01

    Purpose: A major obstacle for MR-only radiotherapy is the need to generate an accurate synthetic CT (sCT) from MR image(s) of a patient for the purposes of dose calculation and DRR generation. We propose here an accurate and efficient atlas-based sCT generation method, which has a computation speed largely independent of the number of atlases used. Methods: Atlas-based sCT generation requires a set of atlases with co-registered CT and MR images. Unlike existing methods that align each atlas to the new patient independently, we first create an average atlas and pre-align every atlas to the average atlas space. When a new patient arrives, we compute only one deformable image registration to align the patient MR image to the average atlas, which indirectly aligns the patient to all pre-aligned atlases. A patch-based non-local weighted fusion is performed in the average atlas space to generate the sCT for the patient, which is then warped back to the original patient space. We further adapt a PatchMatch algorithm that can quickly find top matches between patches of the patient image and all atlas images, which makes the patch fusion step also independent of the number of atlases used. Results: Nineteen brain tumour patients with both CT and T1-weighted MR images are used as testing data and a leave-one-out validation is performed. Each sCT generated is compared against the original CT image of the same patient on a voxel-by-voxel basis. The proposed method produces a mean absolute error (MAE) of 98.6±26.9 HU overall. The accuracy is comparable with a conventional implementation scheme, but the computation time is reduced from over an hour to four minutes. Conclusion: An average atlas space patch fusion approach can produce highly accurate sCT estimations very efficiently. Further validation on dose computation accuracy and using a larger patient cohort is warranted. The author is a full time employee of Elekta, Inc.

  20. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  1. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  2. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  3. Comment traduire en japonais les styles indirect et indirect libre de Madame Bovary ?

    Directory of Open Access Journals (Sweden)

    Hisaki Sawasaki

    2012-03-01

    Full Text Available Parmi les difficultés rencontrées lors de la traduction des textes littéraires occidentaux, en japonais, nous examinons le problème des styles indirect et indirect libre. Pour cela, en effectuant une petite mise au point grammaticale, nous comparons sept traductions de Madame Bovary de Gustave Flaubert, dont les dates de parution s’étendent sur une cinquantaine d’années. Cette période s’apparente, de notre point de vue, à un long itinéraire pour assimiler la notion occidentale des styles direct et indirect, tout en la conciliant avec les particularités du japonais. D’un autre côté, ce travail acharné des traducteurs a influencé quelque peu la langue japonaise. On trouve dans l’annexe tous les textes en japonais examinés.We will examine the difficulties met when translating Western literary texts in Japanese, in particular the problem of indirect and free indirect styles. We will define the grammatical issue and compare seven translations of Madame Bovary, published over a fifty year period. This time can be likened to a long path taken to digest the Western notion of direct and indirect styles, while reconciling it with Japanese language characteristics. On the other hand the translators’ relentless work has somewhat influenced the Japanese language. The annex will present all the Japanese texts examined.

  4. Language shifts in free indirect discourse

    NARCIS (Netherlands)

    Maier, Emar

    Free indirect discourse is a way of reporting what a protagonist thinks or says that is distinct from both direct and indirect discourse. In particular, while pronouns and tenses are presented from the narrator's perspective, as in indirect discourse, other indexical and expressive elements reflect

  5. Directe en indirecte werknemersparticipatie in Europa

    NARCIS (Netherlands)

    van Houten, Gijs; Akkerman, Agnes; Sluiter, Roderick; Jansen, Giedo; Vermeylen, Greet

    2016-01-01

    This study looks at different forms of direct and indirect employee participation in the EU. The research questions are: (1) which forms of direct and indirect employee participation can we distinguish?; (2) to what extent do forms of direct and indirect employee participation coincide within

  6. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  7. The logic of indirect speech

    Science.gov (United States)

    Pinker, Steven; Nowak, Martin A.; Lee, James J.

    2008-01-01

    When people speak, they often insinuate their intent indirectly rather than stating it as a bald proposition. Examples include sexual come-ons, veiled threats, polite requests, and concealed bribes. We propose a three-part theory of indirect speech, based on the idea that human communication involves a mixture of cooperation and conflict. First, indirect requests allow for plausible deniability, in which a cooperative listener can accept the request, but an uncooperative one cannot react adversarially to it. This intuition is supported by a game-theoretic model that predicts the costs and benefits to a speaker of direct and indirect requests. Second, language has two functions: to convey information and to negotiate the type of relationship holding between speaker and hearer (in particular, dominance, communality, or reciprocity). The emotional costs of a mismatch in the assumed relationship type can create a need for plausible deniability and, thereby, select for indirectness even when there are no tangible costs. Third, people perceive language as a digital medium, which allows a sentence to generate common knowledge, to propagate a message with high fidelity, and to serve as a reference point in coordination games. This feature makes an indirect request qualitatively different from a direct one even when the speaker and listener can infer each other's intentions with high confidence. PMID:18199841

  8. Indirect Cost Reimbursement: An Industrial View.

    Science.gov (United States)

    Bolton, Robert

    1987-01-01

    The meaning of indirect costs in an industrial environment is discussed. Other factors considered are corporate policies; nature of work being supported; the uniqueness of the work; who is doing the negotiating for industry; and indirect rates. Suggestions are offered for approaches to indirect cost reimbursement. (Author/MLW)

  9. Blunt traumatic rupture of a mainstem bronchus: spiral CT demonstration of the ''fallen lung'' sign

    Energy Technology Data Exchange (ETDEWEB)

    Wintermark, M.; Schnyder, P.; Wicky, S. [Dept. of Diagnostic and Interventional Radiology, University Hospital, Lausanne (Switzerland)

    2001-03-01

    Tracheo-bronchial injuries occur in less than 1 % of blunt chest trauma patients. Indirect signs, such as pneumomediastinum, pneumothorax, and/or subcutaneous emphysema, are revealed on admission plain films and chest CT survey. In most instances, however, tracheo-bronchoscopy is mandatory in assessing the definite diagnosis of tracheo-bronchial lesion. Occasionally, an abnormal course of a mainstem bronchus or a ''fallen lung'' sign, featuring a collapsed lung in a dependent position, hanging on the hilum only by its vascular attachments, may allow for CT diagnosis of a blunt traumatic bronchial injury. (orig.)

  10. Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.

    Science.gov (United States)

    Holly, Brian P; Steenburg, Scott D

    2011-01-01

    Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.

  11. Assessment of airway lesion in obstructive lung diseases by CT

    International Nuclear Information System (INIS)

    Niimi, Akio; Matsumoto, Hisako; Ueda, Tetsuya; Mishima, Michiaki

    2002-01-01

    Airway lesion in obstructive pulmonary diseases, such as asthma or chronic obstructive pulmonary disease (COPD), has recently been assessed quantitatively. Especially in asthma, wall thickening of central airways, and its relation to the severity of disease or airflow obstruction has been clarified. Pathophysiologic importance of peripheral airway lesion has also been highlighted by pathologic or physiologic studies. However, direct evaluation of peripheral airway lesion is beyond resolutional limitation of CT. To assess airway trapping, an indirect CT finding of peripheral airway disease, by quantitative and semiquantitative measures and compare them with clinical indices such as pulmonary function, airway responsiveness, or airway inflammation. Patients with stable asthma (n=20) were studied. HRCT at 3 levels of both lungs were scanned. Low attenuation area (LAA)% and mean lung density were quantitatively assessed by an automatic method. Distribution of mosaic pattern was visually scored semiquantitatively. LAA% and mean lung density at full expiratory phase correlated with the degree of airflow obstruction. Mosaic score at full inspiratory phase correlated with the severity of disease and airflow obstruction. Expiratory/inspiratory ratio of mean lung density was also associated with airway responsiveness or residual volume/total lung capacity (RV/TLC). These CT findings may be useful as markers of asthma pathophysiology. (author)

  12. MR venography using the 3D-MEDIC (multi echo data imaging combination) sequence for lower extremities

    International Nuclear Information System (INIS)

    Kitagawa, Hisashi; Kishi, Takayuki; Saito, Ryo; Shohji, Tomokazu; Noguchi, Keiji; Sunohara, Nobuo

    2008-01-01

    It is possible to diagnose varicose vein from medical history and physical examinations including inspection and palpation. Non-contrast enhanced MRV (magnetic resonance venography) is becoming popular because it can be easily performed without being affected by the radiographer's skill. We thought that the use of MEDIC (multi echo data imaging combination) would enable us to delineate varicose veins within a short acquisition time and without need for synchronization or contrast enhancement. We used the SIEMENS MAGNETOM Avanto 1.5-Tesla unit to acquire images. Our subjects were five healthy volunteers and five patients with varicose vein. The signal strength of deep veins and muscles were measured. The SNR (signal-to-nose ratio) of deep veins and the CNR (contrast-to-noise ratio) between deep veins and muscles were also measured. Flip angle, fat suppression methods, MTC (magnetic transfer contrast) pulse, and combined echo. Using the optimum image acquisition protocol following our preliminary study with varicose vein patients, the ability of the 3D-MEDIC method to delineate varicose veins was compared with that of the electrocardiogram (ECG)-synchronized two-dimensional time of flight (2D-TOF) method. We found that the following settings would enable us to acquire images from a wide range=coronal, within short acquisition time and needless ECG-triggering. Flip angle=20 degrees, fat suppression method=water excitation, MTC pulse=ON, combined echo=2. 3D-MEDIC was better than the 2D-TOF method in delineating the varicose vein itself and the connection between the varicose vein and deep veins. It is expected that 3D-MEDIC may be useful in the clinical diagnosis of varicose veins. (author)

  13. Vascular Complications of Intercavernous Sinuses during Transsphenoidal Surgery: An Anatomical Analysis Based on Autopsy and Magnetic Resonance Venography.

    Directory of Open Access Journals (Sweden)

    Xuefei Deng

    Full Text Available Vascular complications induced by intercavernous sinus injury during dural opening in the transsphenoidal surgery may contribute to incomplete tumour resections. Preoperative neuro-imaging is of crucial importance in planning surgical approach. The aim of this study is to correlate the microanatomy of intercavernous sinuses with its contrast-enhanced magnetic resonance venography (CE-MRV.Eighteen human adult cadavers and 24 patients were examined based on autopsy and CE-MRV. Through dissection of the cadavers and CE-MRV, the location, shape, number, diameter and type of intercavernous sinuses were measured and compared.Different intercavernous sinuses were identified by their location and shape in all the cadavers and CE-MRV. Compared to the cadavers, CE-MRV revealed 37% of the anterior intercavernous sinus, 48% of the inferior intercavernous sinus, 30% of the posterior intercavernous sinus, 30% of the dorsum sellae sinus and 100% of the basilar sinus. The smaller intercavernous sinuses were not seen in the neuro-images. According to the presence of the anterior and inferior intercavernous sinus, four types of the intercavernous sinuses were identified in cadavers and CE-MRV, and the corresponding operative space in the transsphenoidal surgical approach was implemented.The morphology and classification of the cavernous sinus can be identified by CE-MRV, especially for the larger vessels, which cause bleeding more easily. Therefore, CE-MRV provides a reliable measure for individualized preoperative planning during transsphenoidal surgery.

  14. Indirect Calorimetry in Mechanically Ventilated Patients

    DEFF Research Database (Denmark)

    Allingstrup, Matilde Jo; Kondrup, Jens; Perner, Anders

    2017-01-01

    Background and Aims: The 2 currently available indirect calorimeters, CCM Express Indirect Calorimeter (MedGraphics, St Paul, MN) and Quark RMR ICU Indirect Calorimeter (COSMED, Rome, Italy), have not been validated against a gold standard in mechanically ventilated patients. Our aim was to do so...... using a gold-standard, modified Tissot bell-spirometer method in mechanically ventilated patients who were hemodynamically, respiratory, and metabolically stable. Methods: We studied 30 patients undergoing general anesthesia and major gynecological surgery. We measured oxygen consumption ((Formula...... of 77 (167) with limits of agreement −249 to 404 kcal/d. Conclusions: The QUARK RMR ICU Indirect Calorimeter compared better with the gold standard for values of (Formula presented.) O2 and REE than did the CCM Express Indirect Calorimeter in mechanically ventilated patients who were circulatory...

  15. Ranking of CT in persistent vertigo after implantation of stapes prostheses; Stellenwert der Computertomographie bei persistierenden Gleichgewichtsstoerungen nach dem Einsatz von Stapesplastiken

    Energy Technology Data Exchange (ETDEWEB)

    Koesling, S. [Leipzig Univ. (Germany). Klinik fuer Diagnostische Radiologie; Woldag, K. [Leipzig Univ. (Germany). Klinik und Poliklinik fuer Hals-Nasen-Ohren-Krankheiten; Meister, E.F. [Leipzig Univ. (Germany). Klinik und Poliklinik fuer Hals-Nasen-Ohren-Krankheiten; Reschke, I. [Leipzig Univ. (Germany). Klinik fuer Diagnostische Radiologie; Schulz, H.G. [Leipzig Univ. (Germany). Klinik fuer Diagnostische Radiologie

    1995-01-01

    10 of 150 patients had persistent vertigo after implanation of stapes prostheses. These patients were evaluated by high resolution CT in the axial and coronal plane. Scans showed in all cases findings which related to the symptoms. The CT findings were proved intraoperatively in 9 cases. A new indirect sign of a perilymphatic fistula is described in form of an air bulla at the end of the prosthesis. Retympanotomy could be planned better with the help of HR-CT. (orig.) [Deutsch] Von 150 Patienten zeigten 10 nach dem Einsatz einer Stapesprothese eine persistierende vestibulaere Symptomatik. Mittels der hochaufloesenden Felsenbein-CT in axialer und koronarer Schnittfuehrung konnten in allen Faellen in Symptomatik erklaerende Befunde erhoben werden. Eine operative Bestaetigung erfolgte in 9 Faellen. Als bisher in der Literatur in diesem Zusammenhang nicht beschriebenes, indirektes Zeichen einer Perilymphfistel wurde eine kleine Luftblase am Prothesenende nachgewiesen. Die HR-CT hat sich als wesentliche Erleichterung bei der Planung einer Retympanotomie erwiesen. (orig.)

  16. The Complexity of Indirect Translation

    DEFF Research Database (Denmark)

    Wenjie, L. I.

    2017-01-01

    its complex nature, and thus determined that many facets of ITr remain to be studied. The present article will try to encompass the complexity of ITr by looking into the reasons for translating indirectly, the challenge of finding out mediating texts (MTs), indirectness in both translation...... of which have been translated and interpreted indirectly through major languages like English, will be employed as examples. Hopefully, this study will offer more insights into the nature of translation as a social activity and raise further interests in studying translation as a complex phenomenon....

  17. A simplified indirect bonding technique

    Directory of Open Access Journals (Sweden)

    Radha Katiyar

    2014-01-01

    Full Text Available With the advent of lingual orthodontics, indirect bonding technique has become an integral part of practice. It involves placement of brackets initially on the models and then their transfer to teeth with the help of transfer trays. Problems encountered with current indirect bonding techniques used are (1 the possibility of adhesive flash remaining around the base of the brackets which requires removal (2 longer time required for the adhesive to gain enough bond strength for secure tray removal. The new simplified indirect bonding technique presented here overcomes both these problems.

  18. Cost-effectiveness of trauma CT in the trauma room versus the radiology department: the REACT trial

    Energy Technology Data Exchange (ETDEWEB)

    Saltzherr, T.P.; Goslings, J.C. [Academic Medical Center, Trauma Unit Department of Surgery, Amsterdam (Netherlands); Bakker, F.C. [VU University Medical Center, Department of Traumatology, Amsterdam (Netherlands); Beenen, L.F.M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Olff, M. [Academic Medical Center, AMC de Meren, Department of Psychiatry, Amsterdam (Netherlands); Meijssen, K. [VU University Medical Center, Economics Department, Amsterdam (Netherlands); Asselman, F.F. [Academic Medical Center, Concern Staff Department, Amsterdam (Netherlands); Reitsma, J.B. [Academic Medical Center, Department of Clinical Epidemiology, Biostatistics and Bioinformatics, Amsterdam (Netherlands); Dijkgraaf, M.G.W. [Academic Medical Center, Clinical Research Unit, Amsterdam (Netherlands); Collaboration: on behalf of the REACT study group

    2013-01-15

    To determine the cost-effectiveness of trauma room CT compared with CT performed at the radiology department. In this randomised controlled trial, adult patients requiring evaluation in a level 1 trauma centre were included. In the intervention hospital the CT system was located within the trauma room and in the control hospital within the radiology department. Direct and indirect medical costs of the institutionalised stay and diagnostic and therapeutic procedures were calculated. A total of 1,124 patients were randomised with comparable demographic characteristics. Mean number of non-institutionalised days alive was 322.5 in the intervention group (95 % CI 314-331) and 320.7 in the control group (95 % CI 312.1-329.2). Mean costs of diagnostic and therapeutic procedures per hospital inpatient day were EUR554 for the intervention group and EUR468 for the control group. Total mean costs in the intervention group were EUR16,002 (95 % CI 13,075-18,929) and EUR16,635 (95 % CI 13,528-19,743) for the control group (P = 0.77). The present study showed that in trauma patients the setting with a CT system located in the trauma room did not provide any advantages or disadvantages from a health economics perspective over a CT system located in the radiology department. (orig.)

  19. Cost-effectiveness of trauma CT in the trauma room versus the radiology department: the REACT trial

    International Nuclear Information System (INIS)

    Saltzherr, T.P.; Goslings, J.C.; Bakker, F.C.; Beenen, L.F.M.; Olff, M.; Meijssen, K.; Asselman, F.F.; Reitsma, J.B.; Dijkgraaf, M.G.W.

    2013-01-01

    To determine the cost-effectiveness of trauma room CT compared with CT performed at the radiology department. In this randomised controlled trial, adult patients requiring evaluation in a level 1 trauma centre were included. In the intervention hospital the CT system was located within the trauma room and in the control hospital within the radiology department. Direct and indirect medical costs of the institutionalised stay and diagnostic and therapeutic procedures were calculated. A total of 1,124 patients were randomised with comparable demographic characteristics. Mean number of non-institutionalised days alive was 322.5 in the intervention group (95 % CI 314-331) and 320.7 in the control group (95 % CI 312.1-329.2). Mean costs of diagnostic and therapeutic procedures per hospital inpatient day were EUR554 for the intervention group and EUR468 for the control group. Total mean costs in the intervention group were EUR16,002 (95 % CI 13,075-18,929) and EUR16,635 (95 % CI 13,528-19,743) for the control group (P = 0.77). The present study showed that in trauma patients the setting with a CT system located in the trauma room did not provide any advantages or disadvantages from a health economics perspective over a CT system located in the radiology department. (orig.)

  20. Combined MR direct thrombus imaging and non-contrast magnetic resonance venography reveal the evolution of deep vein thrombosis: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Mendichovszky, I.A.; Lomas, D.J. [Addenbrooke' s Hospital, Department of Radiology, Cambridge (United Kingdom); University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Priest, A.N.; Bowden, D.J.; Hunter, S.; Joubert, I.; Hilborne, S.; Graves, M.J. [Addenbrooke' s Hospital, Department of Radiology, Cambridge (United Kingdom); Baglin, T. [Addenbrooke' s Hospital, Department of Haematology, Cambridge (United Kingdom)

    2017-06-15

    Lower limb deep venous thrombosis (DVT) is a common condition with high morbidity and mortality. The aim of the study was to investigate the temporal evolution of the acute thrombus by magnetic resonance imaging (MRI) and its relationship to venous recanalization in patients with recurrent DVTs. Thirteen patients with newly diagnosed lower limb DVTs underwent MRI with non-contrast MR venography (NC-MRV) and MR direct thrombus imaging (MR-DTI), an inversion-recovery water-selective fast gradient-echo acquisition. Imaging was performed within 7 days of the acute thrombotic event, then at 3 and 6 months. By 3 months from the thrombotic event a third of the thrombi had resolved and by 6 months about half of the cases had resolved on the basis of vein recanalisation using NC-MRV. On the initial MR-DTI acute thrombus was clearly depicted by hyperintense signal, while the remaining thrombi were predominantly low signal at 3 and 6 months. Some residual thrombi contained small and fragmented persisting hyperintense areas at 3 months, clearing almost completely by 6 months. Our study suggests that synergistic venous assessment with combined NC-MRV and MR-DTI is able to distinguish acute venous thrombosis from the established (old) or evolving DVT detected by ultrasound. (orig.)

  1. Combined MR direct thrombus imaging and non-contrast magnetic resonance venography reveal the evolution of deep vein thrombosis: a feasibility study

    International Nuclear Information System (INIS)

    Mendichovszky, I.A.; Lomas, D.J.; Priest, A.N.; Bowden, D.J.; Hunter, S.; Joubert, I.; Hilborne, S.; Graves, M.J.; Baglin, T.

    2017-01-01

    Lower limb deep venous thrombosis (DVT) is a common condition with high morbidity and mortality. The aim of the study was to investigate the temporal evolution of the acute thrombus by magnetic resonance imaging (MRI) and its relationship to venous recanalization in patients with recurrent DVTs. Thirteen patients with newly diagnosed lower limb DVTs underwent MRI with non-contrast MR venography (NC-MRV) and MR direct thrombus imaging (MR-DTI), an inversion-recovery water-selective fast gradient-echo acquisition. Imaging was performed within 7 days of the acute thrombotic event, then at 3 and 6 months. By 3 months from the thrombotic event a third of the thrombi had resolved and by 6 months about half of the cases had resolved on the basis of vein recanalisation using NC-MRV. On the initial MR-DTI acute thrombus was clearly depicted by hyperintense signal, while the remaining thrombi were predominantly low signal at 3 and 6 months. Some residual thrombi contained small and fragmented persisting hyperintense areas at 3 months, clearing almost completely by 6 months. Our study suggests that synergistic venous assessment with combined NC-MRV and MR-DTI is able to distinguish acute venous thrombosis from the established (old) or evolving DVT detected by ultrasound. (orig.)

  2. Indirect Reciprocity; A Field Experiment.

    Science.gov (United States)

    van Apeldoorn, Jacobien; Schram, Arthur

    2016-01-01

    Indirect reciprocity involves cooperative acts towards strangers, either in response to their kindness to third parties (downstream) or after receiving kindness from others oneself (upstream). It is considered to be important for the evolution of cooperative behavior amongst humans. Though it has been widely studied theoretically, the empirical evidence of indirect reciprocity has thus far been limited and based solely on behavior in laboratory experiments. We provide evidence from an online environment where members can repeatedly ask and offer services to each other, free of charge. For the purpose of this study we created several new member profiles, which differ only in terms of their serving history. We then sent out a large number of service requests to different members from all over the world. We observe that a service request is more likely to be rewarded for those with a profile history of offering the service (to third parties) in the past. This provides clear evidence of (downstream) indirect reciprocity. We find no support for upstream indirect reciprocity (in this case, rewarding the service request after having previously received the service from third parties), however. Our evidence of downstream indirect reciprocity cannot be attributed to reputational effects concerning one's trustworthiness as a service user.

  3. Role of contrast-enhanced helical CT in the evaluation of acute thoracic aortic injuries after blunt chest trauma

    International Nuclear Information System (INIS)

    Scaglione, M.; Pinto, A.; Pinto, F.; Romano, L.; Ragozzino, A.; Grassi, R.

    2001-01-01

    The purpose of this retrospective study was to determine the value of contrast-enhanced helical CT for detecting and managing acute thoracic aortic injury (ATAI). Between June 1995 and February 2000, 1419 consecutive chest CT examinations were performed in the setting of major blunt trauma. The following CT findings were considered indicative of ATAI: intimal flap; pseudoaneurysm; contour irregularity; lumen abnormality; and extravasation of contrast material. On the basis of these direct findings no further diagnostic investigations were performed. Isolated mediastinal hematoma on CT scans was considered an indirect sign of ATAI: In these cases, thoracic aortography was performed even if CT indicated normal aorta. Seventy-seven patients had abnormal CT scans: Among the 23 patients with direct CT signs, acute thoracic aortic injuries was confirmed at thoracotomy in 21. Two false-positive cases were observed. The 54 remaining patients had isolated mediastinal hematoma without aortic injuries at CT and corresponding negative angiograms. The 1342 patients with negative CT scans were included in the 8-month follow-up program and did not show any adverse sequela based on clinical and radiographic criteria. Contrast-enhanced helical CT has a critical role in the exclusion of thoracic aortic injuries in patient with major blunt chest trauma and prevents unnecessary thoracic aortography. Direct CT signs of ATAI do not require further diagnostic investigations to confirm the diagnosis: Isolated aortic bands or contour vessel abnormalities should be first considered as possible artifacts or related to non-traumatic etiologies especially when mediastinal hematoma is absent. In cases of isolated mediastinal hematoma other possible sources of bleeding should be considered before directing patients to thoracic aortography. (orig.)

  4. Pedal indirect lymphangiography

    International Nuclear Information System (INIS)

    Lee, Kil Woo; Hong, Myung Sun; Kim, In Jae

    1994-01-01

    Recently, indirect lymphangiography has been developed as a relatively good and noninvasive imaging modality of the lymphatic system at extremities. But the disadvantage of the indirect lymphangiography is a low contrast ratio between the surrounding tissues and the contrast media in lymphatic vessels, because dimeric nonionic contrast media is water soluble and diluted in the proximal leg lymphatic vessels. We could have relatively better image than previously published images for the leg lymphatic system, when we injected contrast media with adequate high pressure in intradermal space of the interdigital areas at the foot dorsum. So, we would like to report the results. We could study all 9 lymphedemas(primary: 6, secondary: 3) from April 1990 to May 1993 on outpatient base. They were diagnosed as lymphedema clinically and radiologically. Ten ml of dimeric nonionic aget, iotrolan(Isovist 300) was injected into intradermal space with five 30-gauge needles. The injection speed was more than 0.2 ml/min. We have done one side pedal lymphangiogram in 30 minutes. The evaluation of the anterior superficial lymphatics was according to the criteria of the Weissleder. The results were as follows: 1. All lymphatic vessels from foot to inguinal area could be visualized. 2. Two or three inferior inguinal lymph nodes could be visualized about 42%. 3. The most common abnormal finding of the lymphedma was the neovascularization of the lymphatics on indirect pedal lymphangiogram. If we use adequate technique relatively high pressure injection, correct intradermal needle insertion, adequate soft tissue exposure technique indirect lymphangiography is considered to be a safe and noninvasive imaging modality for the evaluation of the lymphedema of lower extremity lymphatics including inferior inguinal lymph nodes

  5. Characterising and linking X-ray CT derived macroporosity parameters to infiltration in soils with contrasting structures

    DEFF Research Database (Denmark)

    Müller, Karin; Katuwal, Sheela; Young, Iain

    2018-01-01

    with X-ray CT. Kunsat was significantly higher in the Andosol than in the Gleysol at all water potentials, and decreased significantly with depth in both soils. The in situ measurements guided the definition of new macroporosity parameters from the X-ray CT reconstructions. For the Andosol, Kunsat......Soils deliver the regulating ecosystem services of water infiltration and distribution, which can be controlled by macropores. Parameterizing macropore hydraulic properties is challenging due to the lack of direct measurement methods. With tension-disc infiltrometry hydraulic properties near...... saturation can be measured. Differentiating between hydrologically active and non-active pores, at a given water potential, indirectly assesses macropore continuity. Water flow through macropores is controlled by macropore size distribution, tortuosity, and connectivity, which can be directly derived by X...

  6. Supersymmetric dark matter: Indirect detection

    International Nuclear Information System (INIS)

    Bergstroem, L.

    2000-01-01

    Dark matter detection experiments are improving to the point where they can detect or restrict the primary particle physics candidates for non baryonic dark matter. The methods for detection are usually categorized as direct, i.e., searching for signals caused by passage of dark matter particles in terrestrial detectors, or indirect. Indirect detection methods include searching for antimatter and gamma rays, in particular gamma ray lines, in cosmic rays and high-energy neutrinos from the centre of the Earth or Sun caused by accretion and annihilation of dark matter particles. A review is given of recent progress in indirect detection, both on the theoretical and experimental side

  7. INDIRECT LABOR COSTS AND IMPLICATIONS FOR OVERHEAD ALLOCATION

    OpenAIRE

    Bea Chiang

    2013-01-01

    Cost accounting typically allocates indirect labor cost to cost object based on direct labor hours. The allocation process implicitly assumes that indirect labor costs vary proportionally with direct labor hours. The assumption of a linear relationship between indirect and direct labor is particularly suspicious at low production volume levels because there tends to be a fixed component in indirect labor. The linearity assumption is also challenged by recent increasing complexity of indirect ...

  8. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  9. Inertial fusion energy power plant design using the Compact Torus Accelerator: HYLIFE-CT

    International Nuclear Information System (INIS)

    Moir, R.W.; Hammer, J.H.; Hartman, C.W.; Leber, R.L.; Logan, B.G.; Petzoldt, R.W.; Tabak, M.; Tobin, M.T.; Bieri, R.L.; Hoffman, M.A.

    1992-01-01

    The Compact Torus Accelerator (CTA), under development at Lawrence Livermore National Laboratory, offers the promise of a low-cost, high-efficiency, high energy, high-power-density driver for ICF and MICF (Magnetically Insulated ICF) type fusion systems. A CTA with 100 MJ driver capacitor bank energy is predicted to deliver ∼30 MJ CT kinetic energy to a 1 cm 2 target in several nanoseconds for a power density of ∼10 16 watts/cm 2 . The estimated cost of delivered energy is ∼3$/Joule, or $100M for 30 MJ. This driver appears to be cost-effective and, in this regard, is virtually alone among IFE drivers. We discuss indirect-drive ICF with a DT fusion energy gain Q = 70 for a total yield of 2 GJ. The CT can be guided to the target inside a several-meter-long disposable cone made of frozen Li 2 BeF 4 , the same material as the coolant. We have designed a power plant including CT injection, target emplacement, containment, energy recovery, and tritium breeding. The cost of electricity is predicted to be 4.8 cents/kWh, which is competitive with future coal and nuclear costs

  10. Analysis of indirect taxation in Ukraine

    Directory of Open Access Journals (Sweden)

    Khodyakova Olga V.

    2014-01-01

    Full Text Available The goal of the article is analysis of the structure and dynamics of indirect taxes for the previous five years and also the influence of indirect taxation upon formation of income of the State Budget of Ukraine. The article analyses the modern state of indirect taxation in Ukraine. Specific weight of the value added tax, excise tax and customs duty are considered in the structure of tax receipts of the consolidated budget of Ukraine as indirect taxes. The article shows that receipts of the State Budget of Ukraine are mostly provided by indirect taxes. The Ukrainian taxation system is mostly a factor of reduction of the level of economic growth and investment activity in the country and the existing system of administering is not completely capable of excluding the possibility of tax evasion. The prospect of further studies in this direction is improvement of organisation of tax control in Ukraine and differentiation of the value added tax rates depending on the level of consumption of goods and level of income of consumers.

  11. CT of hepatocellular carcinoma. Analysis of contrast-enhanced CT using CT arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Hori, S; Tokunaga, K; Yoshioka, H [Osaka Univ. (Japan). Faculty of Medicine

    1981-02-01

    Although changes in the CT appearance resulting from contrast enhancement (CE) for hepatocellular carcinoma have been considered in association with vascularity of tumors, no detailed studies have yet been made. We analyzed changes in the CT appearance following CE by comparing with hepatic arteriogram and CT arteriogram (CTA) performed during intraarterial infusion of contrast medium. When tumors showing low density in the plain CT were enhanced by contrast, the results were variable, ranging from intensification of the low density to replacement by high density, and the results were classified into L/sub 0/ to L/sub 3/ according to vascularity of tumors. The results after CE could also be classified into I/sub 0/ to I/sub 3/ when tumors showed isodensity in the plain CT. There was a correlation between vascularity presumed from CE and vascularity by CTA. It may be concluded that tumor vascularity could be estimated by the findings of CE which might indicate a possibility of qualitative diagnosis of tumors.

  12. A semiempirical linear model of indirect, flat-panel x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Shih-Ying; Yang Kai; Abbey, Craig K.; Boone, John M. [Department of Biomedical Engineering, University of California, Davis, California, One Shields Avenue, Davis, California 95616 (United States) and Department of Radiology, University of California, Davis, Medical Center, 4860 Y Street, Ambulatory Care Center Suite 0505, Sacramento, California 95817 (United States); Department of Radiology, University of California, Davis, Medical Center, 4860 Y Street, Ambulatory Care Center Suite 0505, Sacramento, California 95817 (United States); Department of Psychological and Brain Sciences, University of California, Santa Barbara, California 92106 (United States); Department of Biomedical Engineering, University of California, Davis, California, One Shields Avenue, Davis, California 95616 (United States) and Department of Radiology, University of California, Davis, Medical Center, 4860 Y Street, Ambulatory Care Center Suite 3100, Sacramento, California 95817 (United States)

    2012-04-15

    Purpose: It is important to understand signal and noise transfer in the indirect, flat-panel x-ray detector when developing and optimizing imaging systems. For optimization where simulating images is necessary, this study introduces a semiempirical model to simulate projection images with user-defined x-ray fluence interaction. Methods: The signal and noise transfer in the indirect, flat-panel x-ray detectors is characterized by statistics consistent with energy-integration of x-ray photons. For an incident x-ray spectrum, x-ray photons are attenuated and absorbed in the x-ray scintillator to produce light photons, which are coupled to photodiodes for signal readout. The signal mean and variance are linearly related to the energy-integrated x-ray spectrum by empirically determined factors. With the known first- and second-order statistics, images can be simulated by incorporating multipixel signal statistics and the modulation transfer function of the imaging system. To estimate the semiempirical input to this model, 500 projection images (using an indirect, flat-panel x-ray detector in the breast CT system) were acquired with 50-100 kilovolt (kV) x-ray spectra filtered with 0.1-mm tin (Sn), 0.2-mm copper (Cu), 1.5-mm aluminum (Al), or 0.05-mm silver (Ag). The signal mean and variance of each detector element and the noise power spectra (NPS) were calculated and incorporated into this model for accuracy. Additionally, the modulation transfer function of the detector system was physically measured and incorporated in the image simulation steps. For validation purposes, simulated and measured projection images of air scans were compared using 40 kV/0.1-mm Sn, 65 kV/0.2-mm Cu, 85 kV/1.5-mm Al, and 95 kV/0.05-mm Ag. Results: The linear relationship between the measured signal statistics and the energy-integrated x-ray spectrum was confirmed and incorporated into the model. The signal mean and variance factors were linearly related to kV for each filter material (r

  13. A semiempirical linear model of indirect, flat-panel x-ray detectors

    International Nuclear Information System (INIS)

    Huang, Shih-Ying; Yang Kai; Abbey, Craig K.; Boone, John M.

    2012-01-01

    Purpose: It is important to understand signal and noise transfer in the indirect, flat-panel x-ray detector when developing and optimizing imaging systems. For optimization where simulating images is necessary, this study introduces a semiempirical model to simulate projection images with user-defined x-ray fluence interaction. Methods: The signal and noise transfer in the indirect, flat-panel x-ray detectors is characterized by statistics consistent with energy-integration of x-ray photons. For an incident x-ray spectrum, x-ray photons are attenuated and absorbed in the x-ray scintillator to produce light photons, which are coupled to photodiodes for signal readout. The signal mean and variance are linearly related to the energy-integrated x-ray spectrum by empirically determined factors. With the known first- and second-order statistics, images can be simulated by incorporating multipixel signal statistics and the modulation transfer function of the imaging system. To estimate the semiempirical input to this model, 500 projection images (using an indirect, flat-panel x-ray detector in the breast CT system) were acquired with 50-100 kilovolt (kV) x-ray spectra filtered with 0.1-mm tin (Sn), 0.2-mm copper (Cu), 1.5-mm aluminum (Al), or 0.05-mm silver (Ag). The signal mean and variance of each detector element and the noise power spectra (NPS) were calculated and incorporated into this model for accuracy. Additionally, the modulation transfer function of the detector system was physically measured and incorporated in the image simulation steps. For validation purposes, simulated and measured projection images of air scans were compared using 40 kV/0.1-mm Sn, 65 kV/0.2-mm Cu, 85 kV/1.5-mm Al, and 95 kV/0.05-mm Ag. Results: The linear relationship between the measured signal statistics and the energy-integrated x-ray spectrum was confirmed and incorporated into the model. The signal mean and variance factors were linearly related to kV for each filter material (r 2 of

  14. A semiempirical linear model of indirect, flat-panel x-ray detectors.

    Science.gov (United States)

    Huang, Shih-Ying; Yang, Kai; Abbey, Craig K; Boone, John M

    2012-04-01

    It is important to understand signal and noise transfer in the indirect, flat-panel x-ray detector when developing and optimizing imaging systems. For optimization where simulating images is necessary, this study introduces a semiempirical model to simulate projection images with user-defined x-ray fluence interaction. The signal and noise transfer in the indirect, flat-panel x-ray detectors is characterized by statistics consistent with energy-integration of x-ray photons. For an incident x-ray spectrum, x-ray photons are attenuated and absorbed in the x-ray scintillator to produce light photons, which are coupled to photodiodes for signal readout. The signal mean and variance are linearly related to the energy-integrated x-ray spectrum by empirically determined factors. With the known first- and second-order statistics, images can be simulated by incorporating multipixel signal statistics and the modulation transfer function of the imaging system. To estimate the semiempirical input to this model, 500 projection images (using an indirect, flat-panel x-ray detector in the breast CT system) were acquired with 50-100 kilovolt (kV) x-ray spectra filtered with 0.1-mm tin (Sn), 0.2-mm copper (Cu), 1.5-mm aluminum (Al), or 0.05-mm silver (Ag). The signal mean and variance of each detector element and the noise power spectra (NPS) were calculated and incorporated into this model for accuracy. Additionally, the modulation transfer function of the detector system was physically measured and incorporated in the image simulation steps. For validation purposes, simulated and measured projection images of air scans were compared using 40 kV∕0.1-mm Sn, 65 kV∕0.2-mm Cu, 85 kV∕1.5-mm Al, and 95 kV∕0.05-mm Ag. The linear relationship between the measured signal statistics and the energy-integrated x-ray spectrum was confirmed and incorporated into the model. The signal mean and variance factors were linearly related to kV for each filter material (r(2) of signal mean to k

  15. Indirect Reciprocity under Incomplete Observation

    Science.gov (United States)

    Nakamura, Mitsuhiro; Masuda, Naoki

    2011-01-01

    Indirect reciprocity, in which individuals help others with a good reputation but not those with a bad reputation, is a mechanism for cooperation in social dilemma situations when individuals do not repeatedly interact with the same partners. In a relatively large society where indirect reciprocity is relevant, individuals may not know each other's reputation even indirectly. Previous studies investigated the situations where individuals playing the game have to determine the action possibly without knowing others' reputations. Nevertheless, the possibility that observers of the game, who generate the reputation of the interacting players, assign reputations without complete information about them has been neglected. Because an individual acts as an interacting player and as an observer on different occasions if indirect reciprocity is endogenously sustained in a society, the incompleteness of information may affect either role. We examine the game of indirect reciprocity when the reputations of players are not necessarily known to observers and to interacting players. We find that the trustful discriminator, which cooperates with good and unknown players and defects against bad players, realizes cooperative societies under seven social norms. Among the seven social norms, three of the four suspicious norms under which cooperation (defection) to unknown players leads to a good (bad) reputation enable cooperation down to a relatively small observation probability. In contrast, the three trustful norms under which both cooperation and defection to unknown players lead to a good reputation are relatively efficient. PMID:21829335

  16. An atlas of radiological anatomy

    International Nuclear Information System (INIS)

    Weir, J.; Abrahams, P.

    1986-01-01

    This book contains a wealth of radiologic images of normal human anatomy; plain radiographs, contrast-enhanced radiographs, and computed tomography (CT) scans. There are 18 pages of magnetic resonance (MR) images, most on the brain and spinal cord, so that there are only two pages on MR imaging of the heart and two pages on abdominal and pelvic MR imaging. Twelve pages of ultrasound (US) images are included. This book has the radiologic image paired with an explanatory drawing; the image is on the left with a paragraph or two of text, and the drawing is on the right with legends. This book includes images of the brain and spinal cord obtained with arteriography, venography, myelography, encephalography, CT, and MR imaging

  17. Traumatic facial nerve palsy: CT patterns of facial nerve canal fracture and correlation with clinical severity

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jae Cheol; Kim, Sang Joon; Park, Hyun Min; Lee, Young Suk; Lee, Jee Young [College of Medicine, Dankook Univ., Chonan (Korea, Republic of)

    2002-07-01

    To analyse the patterns of facial nerve canal injury seen at temporal bone computed tomography (CT) in patients with traumatic facial nerve palsy and to correlate these with clinical manifestations and outcome. Thirty cases of temporal bone CT in 29 patients with traumatic facial nerve palsy were analyzed with regard to the patterns of facial nerve canal involvement. The patterns were correlated with clinical grade, the electroneurographic (ENoG) findings, and clinical outcome. For clinical grading, the House-Brackmann scale was used, as follows:grade I-IV, partial palsy group; grade V-VI, complete palsy group. The electroneuronographic findings were categorized as mild to moderate (below 90%) or severe (90% and over) degeneration. In 25 cases, the bony wall of the facial nerve canals was involved directly (direct finding): discontinuity of the bony wall was onted in 22 cases, bony spicules in ten, and bony wall displacement in five. Indirect findings were canal widening in nine cases and adjacent bone fracture in two. In one case, there were no direct or indirect findings. All cases in which there was complete palsy (n=8) showed one or more direct findings including spicules in six, while in the incomplete palsy group (n=22), 17 cases showed direct findings. In the severe degeneration group (n=13), on ENog, 12 cases demonstrated direct findings, including spicules in nine cases. In 24 patients, symptoms of facial palsy showed improvement at follow up evaluation. Four of the five patients in whom symptoms did not improve had spicules. Among ten patients with spicules, five underwent surgery and symptoms improved in four of these; among the five patients not operated on , symptoms did not improve in three. In most patients with facial palsy after temporal bone injury, temporal bone CT revealed direct or indirect facial nerve canal involvement, and in complete palsy or severe degeneration groups, there were direct findings in most cases. We believe that meticulous

  18. An Indirect Route for Ethanol Production

    Energy Technology Data Exchange (ETDEWEB)

    Eggeman, T.; Verser, D.; Weber, E.

    2005-04-29

    The ZeaChem indirect method is a radically new approach to producing fuel ethanol from renewable resources. Sugar and syngas processing platforms are combined in a novel way that allows all fractions of biomass feedstocks (e.g. carbohydrates, lignins, etc.) to contribute their energy directly into the ethanol product via fermentation and hydrogen based chemical process technologies. The goals of this project were: (1) Collect engineering data necessary for scale-up of the indirect route for ethanol production, and (2) Produce process and economic models to guide the development effort. Both goals were successfully accomplished. The projected economics of the Base Case developed in this work are comparable to today's corn based ethanol technology. Sensitivity analysis shows that significant improvements in economics for the indirect route would result if a biomass feedstock rather that starch hydrolyzate were used as the carbohydrate source. The energy ratio, defined as the ratio of green energy produced divided by the amount of fossil energy consumed, is projected to be 3.11 to 12.32 for the indirect route depending upon the details of implementation. Conventional technology has an energy ratio of 1.34, thus the indirect route will have a significant environmental advantage over today's technology. Energy savings of 7.48 trillion Btu/yr will result when 100 MMgal/yr (neat) of ethanol capacity via the indirect route is placed on-line by the year 2010.

  19. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  20. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  1. Performance comparison of direct and indirect lighting systems

    International Nuclear Information System (INIS)

    Rubinstein, F.; Morse, O.; Clark, T.

    1993-01-01

    The performance of a retrofitted indirect lighting system was compared to the performance of a typical de-lamped direct lighting system in a partitioned office space. Power, illuminance and luminance measurements were made for the de-lamped direct lighting system and after installation of the indirect lighting system with various lamp and ballast combinations. Using the same lamps and ballasts, average workplace illuminance was slightly higher with indirect lighting than with direct lighting. With indirect lighting, workplace lumen efficacy was 4.5% lower due to the higher power draw of the lamps in the more open and cooler indirect fixtures. Indirect lighting with 36 watt T-8 lamps and electronic ballasts achieved an initial average workplace illuminance of 45 foot-candles in the partitioned office space at only 1.1 w/ft 2

  2. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  3. Radiologic evaluation of adrenal glands

    International Nuclear Information System (INIS)

    Pradel, J.; Bruel, J.M.; Taourel, P.; Garnier, T.; Cyteval, C.; Lamarque, J.L.

    1990-01-01

    When a diagnosis of adrenal disorder is suspected on the basis of clinical manifestations and/or laboratory findings, computed tomography (CT) is generally accepted as the imaging procedure of choice for visualization of adrenal areas and localization of lesions. Sonography keeps an important role in discovering adrenal masses during investigation for other suspected abnormality (incidentaloma). 131 I MIBG scintigraphy provides an efficious mean of pheochromocytoma localization and functional characterization. These non invasive procedures have greatly reduced the need for arteriography and venography; adrenal venous sampling is still an useful method for localizing either a tumor or hyperplasia related to primary aldosteronism. MR imaging and CT are nearly equivalent in the detection of adrenal masses: besides MR imaging has a potential for characterization of adrenal masses which might be useful, especially in distinguishing adrenal adenomas from malignant neoplasms, obviating, in some cases, the need of CT guided adrenal biopsy [fr

  4. CT findings of pancreatic carcinoma. Evaluation with the combined method of early enhancement CT and high dose enhancement CT

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Endo, Tokiko; Isomura, Takayuki; Ishigaki, Takeo; Ikeda, Mitsuru; Senda, Kouhei.

    1995-01-01

    Computed tomographic (CT) findings of pancreatic ductal adenocarcinoma were studied with the combined method of early enhancement CT and high dose enhancement CT in 72 carcinomas. Common Findings were change in pancreatic contour, abnormal attenuation in a tumor and dilatation of the main pancreatic duct. The incidence of abnormal attenuation and dilatation of the main pancreatic duct and bile duct was constant regardless of tumor size. The finding of hypoattenuation at early enhancement CT was most useful for demonstrating a carcinoma. However, this finding was negative in ten cases, five of which showed inhomogenous hyperattenuation at high dose enhancement CT. The detection of change in pancreatic contour and dilatation of the main pancreatic duct was most frequent at high dose enhancement CT. The finding of change in pancreatic contour and/or abnormal attenuation in a tumor could be detected in 47 cases at plain CT, 66 at early enhancement CT and 65 at high dose enhancement CT. Since the four cases in which neither finding was detected by any CT method showed dilatated main pancreatic duct, there was no case without abnormal CT findings. This combined CT method will be a reliable diagnostic technique in the imaging of pancreatic carcinoma. (author)

  5. CT in neuromuscular disorders: A comparison of CT and histology

    International Nuclear Information System (INIS)

    Vliet, A.M. van der; Thijssen, H.O.M.; Merx, J.L.; Joosten, E.

    1988-01-01

    The value of CT-examination of the muscles compared to histology was studied in a retrospective analysis of 30 patients with clinical suspicion of neuromuscular disorder. In the evaluation of the CT-results descriptive criteria were used. The histologic diagnosis came from needle-biopsies taken from the quadriceps muscle. Considering the whole group of neuromuscular disorders, CT has an overall accuracy of 84.8%, a positive predictive value of 95.5% and a negative predictive value of 63.6%. This makes the use of CT as a diagnostic tool in neuromuscular disorders a reliable examination technique. In patients with a polymyositis there is even a 100% correlation between CT findings and biopsy results. Discrepancy between the biopsy results is remarkable of the quadriceps muscle and the CT findings: The number of abnormal histological findings is twice the number of abnormal CT findings. Using the more proximal gluteal region as a biopsy site would have decreased this discrepancy and would therefore have given a better correlation between CT and histology. The choice of protocol in determining the levels to be scanned is of great importance in achieving good reproducability in follow-up CT examinations. (orig.)

  6. Ballistic fractures: indirect fracture to bone.

    Science.gov (United States)

    Dougherty, Paul J; Sherman, Don; Dau, Nathan; Bir, Cynthia

    2011-11-01

    Two mechanisms of injury, the temporary cavity and the sonic wave, have been proposed to produce indirect fractures as a projectile passes nearby in tissue. The purpose of this study is to evaluate the temporal relationship of pressure waves using strain gauge technology and high-speed video to elucidate whether the sonic wave, the temporary cavity, or both are responsible for the formation of indirect fractures. Twenty-eight fresh frozen cadaveric diaphyseal tibia (2) and femurs (26) were implanted into ordnance gelatin blocks. Shots were fired using 9- and 5.56-mm bullets traversing through the gelatin only, passing close to the edge of the bone, but not touching, to produce an indirect fracture. High-speed video of the impact event was collected at 20,000 frames/s. Acquisition of the strain data were synchronized with the video at 20,000 Hz. The exact time of fracture was determined by analyzing and comparing the strain gauge output and video. Twenty-eight shots were fired, 2 with 9-mm bullets and 26 with 5.56-mm bullets. Eight indirect fractures that occurred were of a simple (oblique or wedge) pattern. Comparison of the average distance of the projectile from the bone was 9.68 mm (range, 3-20 mm) for fractured specimens and 15.15 mm (range, 7-28 mm) for nonfractured specimens (Student's t test, p = 0.036). In this study, indirect fractures were produced after passage of the projectile. Thus, the temporary cavity, not the sonic wave, was responsible for the indirect fractures.

  7. Indirect effects in dual radiation action

    International Nuclear Information System (INIS)

    Zaider, M.; Rossi, H.H.

    1988-01-01

    The basic aim in this paper is to establish the link between indirect effects of radiation action and the spatial distribution of radicals at the time of energy deposition as well as throughout subsequent diffusion and interaction. The fact that radicals diffuse for a finite distance before damaging a biomolecule has dramatic effects on their subsequent probability to result in lesions. Thus at very low DMSO concentrations, where p = 0.5, one expects - all other things being equal - some 75% of the lesions to result from indirect or semidirect lesions. The number calculated here is lower (15%), a direct result of the fact that such lesions involve proximity functions modulated by diffusion. At higher DMSO concentrations this percentage becomes progressively smaller, as expected. It appears thus that for low-LET radiation, the relative amount of indirect damage in single tracks (also termed intratrack or single events) action is very small. By contrast, intertrack (or two-event) contributions will have the ratio between direct and (indirect + semidirect) contributions given by p 2 /(1-p 2 ). The reason for this is that sublesions from different tracks are uniformly distributed throughout the cell nucleus; their probability of interaction should not depend on any previous diffusional processes. For the example given above (p = 0.5) they do expect 65% of intertrack (two-hit) lesions to have resulted from indirect or semidirect mechanisms. This contrast between the almost exclusively direct character of intratrack lesions and the dominant role of indirect action in intertrack lesions produced by low-LET radiation is an important conclusion of this study

  8. Did low tube voltage CT combined with low contrast media burden protocols accomplish the goal of "double low" for patients? An overview of applications in vessels and abdominal parenchymal organs over the past 5 years.

    Science.gov (United States)

    Shen, Yaqi; Hu, Xuemei; Zou, Xianlun; Zhu, Di; Li, Zhen; Hu, Daoyu

    2016-09-01

    Imaging communities have already reached a consensus that the radiation dose of computed tomography (CT) should be reduced as much as reasonably achievable to lower population risks. Increasing attention is being paid to iodinated contrast media (CM) induced nephrotoxicity (CIN); a decrease in the intake of iodinated CM is required by increasingly more radiologists. Theoretically, the radiation dose varies with the tube current time and square of the tube voltage, with higher iodine contrast at low photon energies (Huda et al. [2000] Radiology, 21 7, 430-435).The use of low tube voltage is a promising strategy to reduce both the radiation dose and CM burden. The term 'double low' has been coined to describe scanning protocols that reduce radiation dose and iodine intake synchronously. These protocols are becoming increasingly popular in the clinical setting. The aim of this review was to describe all original studies using the 'double low' strategy in the last 5 years. We searched an online electronic database (PubMed) from January 2011 to December 2015 for original studies published on the relationship of low tube voltage with low radiation dose and low iodine contrast media burden in patients undergoing CT scans. Studies that failed to reduce radiation dose or iodine CM burden were excluded in this study. Thirty-seven studies aimed at reducing radiation dose using low tube voltage combined with iodine CM reduced protocols were included in this study. Most studies evaluated conditions associated with arteries. Four were cerebral and neck computed tomography angiography (CTA) studies, 15 were pulmonary CTA (pCTA) and coronary CTA (cCTA) studies, one concerned myocardial perfusion, five studies focused on the thoracic and abdominal aorta, and one investigated renal arteries. Three studies consisted of CT venography (CTV) of the pelvis and lower extremities. Six publications examined the liver, and two focused on the kidney. Overall, this review demonstrates that

  9. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  10. Expression of future prospective in indirect speech

    Directory of Open Access Journals (Sweden)

    Bodnaruk Elena Vladimirovna

    2015-03-01

    Full Text Available The article analyzes the characteristics and use of grammatical semantics and lexical and grammatical means used to create future prospects in double indirect discourse. The material for the study were epic works by contemporary German writers. In the analysis of the empirical material it has been pointed out that indirect discourse has preterial basis and is the kind of most frequent inner speech of characters. The most widely used form with future semantics in preterial indirect speech is conditional I, formally having a conjunctive basis, but is mostly used with the indicative semantics. Competitive to conditional I in indirect speech is preterial indicative. A characteristic feature of the indirect speech is the use of modal verbs, which, thanks to its semantics is usually referred as an action at a later term, creating the prospect of future statements. The most frequent were modal verbs wollen and sollen in the form of the preterite, more rare verbs were m ssen and k nnen. German indirect speech distinguishes the ability to use forms on the basis of conjunctive: preterite and plusquamperfect of conjunctive. Both forms express values similar to those of the indicative. However, conjunctive forms the basis of the data shown in a slightly more pronounced seme of uncertainty that accompanies future uses of these forms in indirect speech. In addition, plusquamperfect conjunctive differs from others by the presence of the seme of completeness.

  11. CT portography by multidetector helical CT. Comparison of three rendering models

    International Nuclear Information System (INIS)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki

    2002-01-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  12. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  13. Synchronization of indirectly coupled Lorenz oscillators

    Indian Academy of Sciences (India)

    Synchronization of indirectly coupled Lorenz oscillators: An experimental study. Amit Sharma Manish Dev Shrimali. Synchronization, Coupled Systems and Networks Volume 77 Issue 5 November 2011 pp 881-889 ... The in-phase and anti-phase synchronization of indirectly coupled chaotic oscillators reported in Phys. Rev ...

  14. Indirect estimators in US federal programs

    CERN Document Server

    1996-01-01

    In 1991, a subcommittee of the Federal Committee on Statistical Methodology met to document the use of indirect estimators - that is, estimators which use data drawn from a domain or time different from the domain or time for which an estimate is required. This volume comprises the eight reports which describe the use of indirect estimators and they are based on case studies from a variety of federal programs. As a result, many researchers will find this book provides a valuable survey of how indirect estimators are used in practice and which addresses some of the pitfalls of these methods.

  15. CT arterial portography and CT arteriography with a triple-lumen balloon catheter

    International Nuclear Information System (INIS)

    Murakami, T.; Oi, H.; Hori, M.; Kim, T.; Takahashi, S.; Matsushita, M.; Narumi, Y.; Nakamura, H.

    1997-01-01

    Purpose: To evaluate the usefulness of the triple-lumen balloon catheter in the serial performance of CT arterial portography (CT-AP) and CT arteriography (CT-A). Material and Methods: A combined CT-AP and CT-A examination of 58 patients was carried out in which a cobra-type triple-lumen balloon catheter was used. CT-AP was performed by injecting contrast medium either into the splenic artery through a side-hole in the catheter proximal to the balloon inflated in the common hepatic artery, or into the superior mesentric artery through an end-hole in the catheter. Then CT-A was serially performed by delivering contrast medium either to the common hepatic artery or the proper hepatic artery from the end-hole, or to the accessory right hepatic artery through a side-hole proximal to the inflated balloon. Results: Sufficient CT-APs were obtained in 53 of the 58 patients (91%), CT-A in 42 (72%), and both in 42 (72%). Incomplete CT-AP was due to technical failure or anatomical anomaly, as was incomplete CT-A. No complications were seen. (orig.)

  16. CT-Urography; Urografia CT

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, Ludovico; Grotto, Maurizio [Trieste Univ., Trieste (Italy). Dipartimento di scienze cliniche, morfologiche e tecnologiche, UCO di radiologia; Morra, Aldo [CRO, Aviano (Italy). Reparto di radiologia

    2005-09-15

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography. [Italian] Gli Autori presentano una panoramica sulla Urografia TC (Uro TC). L'avvento della TC multistrato e l'evoluzione delle tecniche di elaborazione consentono di ottenere dei quadri urografici ottimali comparativi con quelli convenzionali. Vengono ricordate le varie tecniche di acquisizione e i protocolli usati dai vari Autori. La dose effettiva di radiazioni ha rappresentato uno dei fattori condizionanti per cui oggi prevale l'orientamento di ridurre il numero di scansioni, considerando dopo la scansione senza mezzo di contrasto un'unica scansione contrasto grafica comprendente sia la fase nefrografica che quella urografica. Con l'uso della TC multistrato la qualita dell'urogramma migliora con l'aumento del numero degli strati. Vengono descritte le varie tecniche di elaborazione, la

  17. THE INDIRECT OBJECT (IO) – ALBANIAN AND ENGLISH

    OpenAIRE

    Shkelqim Millaku; Xhevahire Topanica

    2016-01-01

    The aim of this study is too corporate the function of the indirect object between Albanian and English language. The function and the Albanian typical case for indirect object are dative and ablative. This grammatical phenomena is the full contrast between two languages because in English language doesn’t exist dative and ablative us in Albanian. In Albanian and English language, the indirect object is more heterogenic than the direct object. The indirect (direct) object in both of languages...

  18. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  19. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  20. Indirect reciprocity with optional interactions.

    Science.gov (United States)

    Ghang, Whan; Nowak, Martin A

    2015-01-21

    Indirect reciprocity is a mechanism for the evolution of cooperation that is relevant for prosocial behavior among humans. Indirect reciprocity means that my behavior towards you also depends on what you have done to others. Indirect reciprocity is associated with the evolution of social intelligence and human language. Most approaches to indirect reciprocity assume obligatory interactions, but here we explore optional interactions. In any one round a game between two players is offered. A cooperator accepts a game unless the reputation of the other player indicates a defector. For a game to take place, both players must accept. In a game between a cooperator and a defector, the reputation of the defector is revealed to all players with probability Q. After a sufficiently large number of rounds the identity of all defectors is known and cooperators are no longer exploited. The crucial condition for evolution of cooperation can be written as hQB>1, where h is the average number of rounds per person and B=(b/c)-1 specifies the benefit-to-cost ratio. We analyze both stochastic and deterministic evolutionary game dynamics. We study two extensions that deal with uncertainty: hesitation and malicious gossip. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Indirect Medical Education and Disproportionate Share Adj...

    Data.gov (United States)

    U.S. Department of Health & Human Services — Indirect Medical Education and Disproportionate Share Adjustments to Medicare Inpatient Payment Rates The indirect medical education (IME) and disproportionate share...

  2. Indirect Comorbidity in Childhood and Adolescence

    Directory of Open Access Journals (Sweden)

    William eCopeland

    2013-11-01

    Full Text Available Objective: Comorbidity between psychiatric disorders is common, but pairwise associations between two disorders may be explained by the presence of other diagnoses that are associated with both disorders or indirect comorbidity. Method: Comorbidities of common childhood psychiatric disorders were tested in three community samples of children ages 6 to 17 (8931 observations of 2965 subjects. Psychiatric disorder status in all three samples was assessed with the Child and Adolescent Psychiatric Assessment. Indirect comorbidity was defined as A-B associations that decreased from significance to nonsignificance after adjusting for other disorders. Results: All tested childhood psychiatric disorders were positively associated in bivariate analyses. After adjusting for comorbidities, many ssociations involving a behavioral disorder and an emotional disorder were attenuated suggesting indirect comorbidity. Generalized anxiety and depressive disorders displayed a very high level of overlap (adjusted OR=37.9. All analyses were rerun with depressive disorders grouped with generalized anxiety disorder in a single distress disorders category. In these revised models, all associations between and emotional disorder and a behavior disorder met our criteria for indirect comorbidity except for the association of oppositional defiant disorder with distress disorders (OR=11.3. Follow-up analyses suggested that the indirect associations were primarily accounted for by oppositional defiant disorder and the distress disorder category. There was little evidence of either sex differences or differences by developmental period Conclusions: After accounting for the overlap between depressive disorders with generalized anxiety disorder, direct comorbidity between emotional and behavioral disorders was uncommon. When there was evidence of indirect comorbidity, ODD and distress disorders were the key intermediary diagnoses accounting for the apparent associations.

  3. Optimization of Protocol CT, PET-CT, whole body; Optimizacion de protocolo CT, en PET-CT, de cuerpo entero

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Fredys Santos, E-mail: fsantos@ccss.sa.cr [Caja Costarricense de Seguro Social (ACCPR/CCSS), San Jose (Costa Rica). Area Control de Calidade Y Proteccion Radiologica; Namias, Mauro, E-mail: mnamias@gmail.com [Comision Nacional de Energia Atomica (FCDN/CNEA), Buenos Aires (Argentina). Fundacion Centro Diagnostico Nuclear

    2013-11-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study.

  4. New possibilities in the diagnosis of ischemia. CT-FFR and CT-Perfusion; Neue Moeglichkeiten der Ischaemiediagnostik. CT-FFR und CT-Perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, Lukas [Herz- und Gefaessklinik, Bad Neustadt an der Saale (Germany). Abt. fuer Radiologie; Krieghoff, Christian [Herzzentrum Leipzig (Germany); Gutberlet, Matthias [Herzzentrum Leipzig (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Leipzig Univ. (Germany). Kardiologische Bildgebung

    2017-12-15

    Coronary CT-angiography (CCTA) plays an increasing role in the primary diagnostics of coronary artery disease (CAD) according to the present guidelines but also in clinical reality. The sensitivity and negative predictive value of CCTA is very high, but the specificity could still be improved. Newer techniques to assess myocardial ischemia like CT-FFR and CT-Perfusion may help to achieve that goal.

  5. Forecasting of indirect consumables for a Job Shop

    Science.gov (United States)

    Shakeel, M.; Khan, S.; Khan, W. A.

    2016-08-01

    A job shop has an arrangement where similar machines (Direct consumables) are grouped together and use indirect consumables to produce a product. The indirect consumables include hack saw blades, emery paper, painting brush etc. The job shop is serving various orders at a particular time for the optimal operation of job shop. Forecasting is required to predict the demand of direct and indirect consumables in a job shop. Forecasting is also needed to manage lead time, optimize inventory cost and stock outs. The objective of this research is to obtain the forecast for indirect consumables. The paper shows how job shop can manage their indirect consumables more accurately by establishing a new technique of forecasting. This results in profitable use of job shop by multiple users.

  6. CT of laryngotracheal trauma

    International Nuclear Information System (INIS)

    Lupetin, A.R.; Daffner, R.H.

    1991-01-01

    This paper evaluates the usefulness of CT for the diagnosis of traumatic laryngotracheal abnormalities. The authors retrospectively evaluated the neck CT studies of 50 patients (36 males, 14 females; age range, 16-75 years) who presented to a level I trauma center after suffering a blunt or penetrating laryngotracheal injury. CT results were correlated with endoscopic or surgical findings in 43 cases. Three groups emerge. CT positive: hyloid bone or laryngotracheal cartilage injury; CT positive: soft-tissue injury only; and CT negative. In group 1, CT demonstrated all bony or cartilaginous injuries proved at surgery or suggested at endoscopy. CT failed to demonstrate laryngotracheal separation in 1 case. In group 2, CT demonstrated all soft-tissue injuries suggested at endoscopy. In group 3, CT findings agreed with those of endoscopy in 7 cases, but minor soft-tissue findings seen at endoscopy were missed in 3 cases. Seven patients were studied only with CT. Ct is an accurate technique for detecting bony or cartilaginous laryngotracheal traumatic abnormalities. However, laryngotracheal separation and minor soft-tissue injuries can be missed

  7. CT-Urography

    International Nuclear Information System (INIS)

    Dalla Palma, Ludovico; Grotto, Maurizio; Morra, Aldo

    2005-01-01

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography [it

  8. CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current

    International Nuclear Information System (INIS)

    Kamel, Ehab; Hany, Thomas F.; Burger, Cyrill; Treyer, Valerie; Schulthess von, Gustav K.; Buck, Alfred; Lonn, Albert H.R.

    2002-01-01

    With the introduction of combined positron emission tomography/computed tomography (PET/CT) systems, several questions have to be answered. In this work we addressed two of these questions: (a) to what value can the CT tube current be reduced while still yielding adequate maps for the attenuation correction of PET emission scans and (b) how do quantified uptake values in tumours derived from CT and germanium-68 attenuation correction compare. In 26 tumour patients, multidetector CT scans were acquired with 10, 40, 80 and 120 mA (CT 10 , CT 40 , CT 80 and CT 120 ) and used for the attenuation correction of a single FDG PET emission scan, yielding four PET scans designated PET CT10 -PET CT120 . In 60 tumorous lesions, FDG uptake and lesion size were quantified on PET CT10 -PET CT120 . In another group of 18 patients, one CT scan acquired with 80 mA and a standard transmission scan acquired using 68 Ge sources were employed for the attenuation correction of the FDG emission scan (PET CT80 , PET 68Ge ). Uptake values and lesion size in 26 lesions were compared on PET CT80 and PET 68Ge . In the first group of patients, analysis of variance revealed no significant effect of CT current on tumour FDG uptake or lesion size. In the second group, tumour FDG uptake was slightly higher using CT compared with 68 Ge attenuation correction, especially in lesions with high FDG uptake. Lesion size was similar on PET CT80 and PET 68Ge . In conclusion, low CT currents yield adequate maps for the attenuation correction of PET emission scans. Although the discrepancy between CT- and 68 Ge-derived uptake values is probably not relevant in most cases, it should be kept in mind if standardised uptake values derived from CT and 68 Ge attenuation correction are compared. (orig.)

  9. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.; Ganzkoerper-Computertomographie. Spiral- und Multislice-CT

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-07-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  10. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  11. Direct and indirect punishment among strangers in the field.

    Science.gov (United States)

    Balafoutas, Loukas; Nikiforakis, Nikos; Rockenbach, Bettina

    2014-11-11

    Many interactions in modern human societies are among strangers. Explaining cooperation in such interactions is challenging. The two most prominent explanations critically depend on individuals' willingness to punish defectors: In models of direct punishment, individuals punish antisocial behavior at a personal cost, whereas in models of indirect reciprocity, they punish indirectly by withholding rewards. We investigate these competing explanations in a field experiment with real-life interactions among strangers. We find clear evidence of both direct and indirect punishment. Direct punishment is not rewarded by strangers and, in line with models of indirect reciprocity, is crowded out by indirect punishment opportunities. The existence of direct and indirect punishment in daily life indicates the importance of both means for understanding the evolution of cooperation.

  12. Imaging diagnosis of alveolar echinococcosis in young patients

    International Nuclear Information System (INIS)

    Sasaki, F.; Ohkawa, Y.; Sato, N.; Uchino, J.; Hata, Y.

    1997-01-01

    We review the imaging findings in seven children with alveolar echinococcosis of the liver. Calcification was seen on plain abdominal films in five of seven patients (66.6 %); the calcifications were small or coarse with irregular margins. Ultrasound was performed in four cases, identifying the lesions in all four as small calcifications with or without cysts. Computed tomography (CT) was performed in four cases and showed small calcifications, calcifications surrounding a cyst, or an aggregate of calcifications. Angiography was performed in all seven patients and showed changes of intrahepatic arterial stretching, overgrowth of small arteries, and a honeycomb pattern in the capillary phase. Venography revealed compression of the inferior vena cava in two patients. Serum screening together with ultrasonography and CT are useful for diagnostic imaging of alveolar echinococcosis. (orig.). With 3 figs., 2 tabs

  13. The effect of the cranial bone CT numbers on the brain CT numbers

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Hitoshi; Kobayashi, Shotai; Koide, Hiromi; Yamaguchi, Shuhei; Okada, Kazunori; Shimote, Koichi; Tsunematsu, Tokugoro (Shimane Medical Univ., Izumo (Japan))

    1989-06-01

    The effects of the cranial size and the computed tomography (CT) numbers of the cranial bone on that of the brain were studied in 70 subjects, aged from 30 to 94 years. The subjects had no histories of cerebrovascular accidents and showed no abnormalities in the central nervous system upon physical examinations and a CT scan. We measured the average attenuation values (CT numbers) of each elliptical region (165 pixels, 0.39 cm{sup 2}) at the bilateral thalamus and at twelve areas of the deep white matter. Multiple regression analysis was used to assess the effects of age, cranial size, and cranial bone CT numbers on the brain CT numbers. The effect of the cranial bone CT numbers on the brain CT numbers was statistically significant. The brain CT numbers increased with the increase in the cranial bone CT numbers. There was, however, no significant correlation between brain CT numbers and cranial size. In measuring the brain CT numbers, it is desirable that consideration be given to the cranial bone CT numbers. (author).

  14. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    Science.gov (United States)

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by

  15. JUSTIFICATION FOR INDIRECT DISCRIMINATION IN EU

    Directory of Open Access Journals (Sweden)

    Cătălina-Adriana Ivănuş

    2014-11-01

    Full Text Available The right to non-discrimination is very important for a civilized society. EU legislation establishes direct and indirect discrimination, harassment, sexual harassment, instruction to discriminate and any less favourable treatment of a woman related to pregnancy or maternity leave as forms of discrimination. The law and the Court of Justice permit the justification of indirect discrimination.

  16. JUSTIFICATION FOR INDIRECT DISCRIMINATION IN EU

    OpenAIRE

    Cătălina-Adriana Ivănuş

    2014-01-01

    The right to non-discrimination is very important for a civilized society. EU legislation establishes direct and indirect discrimination, harassment, sexual harassment, instruction to discriminate and any less favourable treatment of a woman related to pregnancy or maternity leave as forms of discrimination. The law and the Court of Justice permit the justification of indirect discrimination.

  17. Picture analysis in CT-HF and its CT photographs

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Kohirasawa, Hideo; Shinojima, Masayasu; Tokui, Mitsuru; Seo, Kunihiko.

    1980-01-01

    CT (computed tomography) apparatus is rarely used yet in the field of dentistry, though it seems useful. It is possibly because of the artefacts caused by the metallic parts attached to teeth, the large partial volume effect due to many bones and the problems of positioning and reproducibility. After considering the various requirements of the CT apparatuses in dental field, CT-HF (of T/R type) was chosen as such apparatus, and installed as the first in dentistry. In the CT-HF apparatus, the inner diameter of the gantry is up to 300 mm, and the position of a tomographic plane is only 40 mm away from the front of gantry. Mainly the usefulness of scanography in positioning and the usefulness of the CT apparatus in the picture analysis and processing in dental field are described. (J.P.N.)

  18. Indirect Genetic Effects for group-housed animals

    DEFF Research Database (Denmark)

    Alemu, Setegn Worku

    This thesis investigated social interactions in group-housed animals. The main findings of this thesis: 1) Statistical methods to estimate indirect genetic effects when interactions differ between kin vs. non-kin were developed. 2) Indirect genetic effects contribute a substantial amount...... of heritable variation for bite mark traits in group-housed min. 3) Indirect genetic effects estimation needs to take into account systematic interactions due to sex or kin for bite mark trait in group-housed min. 4) Genomic selection can be used to increase the response to selection for survival time in Brown...

  19. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  20. Accuracy of software-assisted contour propagation from planning CT to cone beam CT in head and neck radiotherapy

    DEFF Research Database (Denmark)

    Hvid, Christian A.; Elstrøm, Ulrik V.; Jensen, Kenneth

    2016-01-01

    ) algorithm for organs at risk (OAR) in the neck region, when applied to CBCT. Material and methods: For 30 head and neck cancer (HNC) patients 14 OARs including parotid glands, swallowing structures and spinal cord were delineated. Contours were propagated by DIR from CT to the CBCTs of the first and last...... consequences of uncertainties in DIR were reviewed. Results: Mean DSC values of ≥0.8 were considered adequate and were achieved in tongue base (0.91), esophagus (0.85), glottic (0.81) and supraglottic larynx (0.83), inferior pharyngeal constrictor muscle (0.84), spinal cord (0.89) and all salivary glands...... in the first CBCT. For the last CBCT by direct propagation, adequate DSC values were achieved for tongue base (0.85), esophagus (0.84), spinal cord (0.87) and all salivary glands. Using indirect propagation only tongue base (0.80) and parotid glands (0.87) were ≥0.8. Mean relative dose difference between...

  1. Indirectness in Discourse: Ethnicity as Conversational Style.

    Science.gov (United States)

    Tannen, Deborah

    1981-01-01

    Examines social differences in expectations of indirectness in conversations between married couples, both Greek and Greek-American. Concludes that Greeks are more likely to expect indirectness in the context presented and that Greek-Americans have retained the Greek communicative patterns. (FL)

  2. Manifestation of Aerosol Indirect Effects in Arctic Clouds

    Science.gov (United States)

    Lubin, D.; Vogelmann, A. M.

    2009-12-01

    The first aerosol indirect effect has traditionally been conceived as an enhancement of shortwave cloud reflectance in response to decreased effective droplet size at fixed liquid water path, as cloud nucleating aerosol becomes entrained in the cloud. The high Arctic, with its pervasive low-level stratiform cloud cover and frequent episodes of anthropogenic aerosol (Artic "haze"), has in recent years served as a natural laboratory for research on actual manifestations of aerosol indirect effects. This paper will review the surprising set of developments: (1) the detection of the indirect effect as a source of surface warming, rather than cooling, throughout early spring, (2) a transition to a cooling effect in late spring, corresponding to the beginning of the sea ice melt season, and (3) detection of an indirect effect during summer, outside of the "Arctic haze" season. This paper will also discuss measurements of spectral shortwave irradiance (350-2200 nm) made at Barrow, Alaska, during the U.S. Department of Energy's Indirect and Semi-Direct Aerosol Campaign (ISDAC), which reveal complications in our conception of the indirect effect related to the ice phase in Arctic stratiform clouds.

  3. Smoking Cessation Is Associated With Lower Indirect Costs.

    Science.gov (United States)

    Baker, Christine L; Bruno, Marianna; Emir, Birol; Li, Vicky W; Goren, Amir

    2018-06-01

    This study quantified differences in indirect costs due to decreased work productivity between current and former smokers. Former smokers were further categorized by number of years since quitting to assess corresponding differences. Data on employed individuals were obtained from the 2013 US National Health and Wellness Survey (NHWS; N = 75,000). Indirect costs were calculated for current smokers and former smokers from weekly wages based on age and sex. The annual total indirect costs for current smokers were $1327.53, $1560.18, and $1839.87 higher than for those who quit 0 to 4 years, 5 to 10 years, and more than or equal to 11 years prior, respectively. There were no significant differences in mean total indirect costs between the former smoker groups. Current smokers showed significantly higher total annual indirect costs compared with former smokers, independently of the number of years since quitting smoking.

  4. Metal artifact reduction of CT scans to improve PET/CT

    NARCIS (Netherlands)

    Van Der Vos, Charlotte S.; Arens, Anne I.J.; Hamill, James J.; Hofmann, Christian; Panin, Vladimir Y.; Meeuwis, Antoi P.W.; Visser, Eric P.; De Geus-Oei, Lioe Fee

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  5. Metal Artifact Reduction of CT Scans to Improve PET/CT

    NARCIS (Netherlands)

    Vos, C.S. van der; Arens, A.I.J.; Hamill, J.J.; Hofmann, C.; Panin, V.Y.; Meeuwis, A.P.W.; Visser, E.P.; Geus-Oei, L.F. de

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  6. On the Relative Size of Direct and Indirect Taxation

    OpenAIRE

    Soldatos, Gerasimos T.

    2014-01-01

    Modifying the standard analytical apparatuses for direct and indirect tax evasion to incorporate forward indirect tax shift in a monopolistically competitive environment, this paper maintains that indirect tax evasion would exceed for sure direct tax evasion only under consumer risk neutrality and a tax policy zeroing the tax shift. Also, in the presence of tax evasion, there cannot be optimal direct-indirect tax mix, because tax evasion is accompanied by uncertainty and hence, nonlinearities...

  7. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  8. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    Science.gov (United States)

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  9. THORACIC COMPLICATIONS OF OESOPHAGEAL CARCINOMA- A RETROSPECTIVE ANALYSIS OF CT APPEARANCES

    Directory of Open Access Journals (Sweden)

    Piyush Joshi

    2017-07-01

    Full Text Available BACKGROUND Oesophageal cancer is a common gastrointestinal tract malignancy and Computed Tomography (CT is generally used for its initial evaluation and staging. Due to the anatomical relationships of the oesophagus, malignancies afflicting it can also give rise to various pulmonary and thoracic complications. The staging CT can also be used to detect and evaluate these complications. Detection of concurrent thoracic complications in addition to the primary malignancy is imperative to institute appropriate management. The aim of the study is to analyse and discuss the various thoracic complications in cases of oesophageal carcinoma detected on Multidetector Computed Tomography (MDCT. MATERIALS AND METHODS MDCT images of 27 cases of histopathologically-proven carcinoma oesophagus who had thoracic complications in addition to features of malignancy and metastases were retrospectively analysed. The various pulmonary and thoracic complications in addition to the primary lesions were assessed and evaluated. RESULTS There were 27 cases of oesophageal carcinoma with complications, of which there were 20 patients who had pulmonary consolidation/pneumonitis, 5 had oesophago-respiratory fistulae, 1 had a lung abscess, 2 had pericardial effusions, 3 had pleural effusions, 2 cases of airway compromise with atelectasis and 2 cases with Pulmonary Thromboembolism (PTE. CONCLUSION The routine chest CT for evaluation and staging of the primary tumour in cases of oesophageal carcinoma can also reveal thoracic complications directly or indirectly related the cancer some of which may alter management. The most common of these are pneumonia and oesophago-respiratory fistulas. Others like pulmonary thromboembolism may require immediate intervention. An awareness of the spectrum of imaging appearances of these complications and due vigilance while interpreting chest CT studies will aid decision making and institution of appropriate management.

  10. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  11. System markets: Indirect network effects in action, or inaction?

    NARCIS (Netherlands)

    J.L.G. Binken (Jeroen)

    2010-01-01

    textabstractIn this dissertation, I empirically examine system markets up close. More specifically I examine indirect network effects, both demand-side and supply-side indirect network effects. Indirect network effects are the source of positive feedback in system markets, or so network effect

  12. 21 CFR 870.3640 - Indirect pacemaker generator function analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Indirect pacemaker generator function analyzer... Indirect pacemaker generator function analyzer. (a) Identification. An indirect pacemaker generator function analyzer is an electrically powered device that is used to determine pacemaker function or...

  13. Analysis of death in major trauma: value of prompt post mortem computed tomography (pmCT) in comparison to office hour autopsy.

    Science.gov (United States)

    Schmitt-Sody, Markus; Kurz, Stefanie; Reiser, Maximilian; Kanz, Karl Georg; Kirchhoff, Chlodwig; Peschel, Oliver; Kirchhoff, Sonja

    2016-03-29

    To analyze diagnostic accuracy of prompt post mortem Computed Tomography (pmCT) in determining causes of death in patients who died during trauma room management and to compare the results to gold standard autopsy during office hours. Multiple injured patients who died during trauma room care were enrolled. PmCT was performed immediately followed by autopsy during office hours. PmCT and autopsy were analyzed primarily regarding pmCT ability to find causes of death and secondarily to define exact causes of death including accurate anatomic localizations. For the secondary analysis data was divided in group-I with equal results of pmCT and autopsy, group-II with autopsy providing superior results and group-III with pmCT providing superior information contributing to but not majorly causing death. Seventeen multiple trauma patients were enrolled. Since multiple trauma patients were enrolled more injuries than patients are provided. Eight patients sustained deadly head injuries (47.1%), 11 chest (64.7%), 4 skeletal system (23.5%) injuries and one patient drowned (5.8%). Primary analysis revealed in 16/17 patients (94.1%) causes of death in accordance with autopsy. Secondary analysis revealed in 9/17 cases (group-I) good agreement of autopsy and pmCT. In seven cases autopsy provided superior results (group-II) whereas in 1 case pmCT found more information (group-III). The presented work studied the diagnostic value of pmCT in defining causes of death in comparison to standard autopsy. Primary analysis revealed that in 94.1% of cases pmCT was able to define causes of death even if only indirect signs were present. Secondary analysis showed that pmCT and autopsy showed equal results regarding causes of death in 52.9%. PmCT is useful in traumatic death allowing for an immediate identification of causes of death and providing detailed information on bony lesions, brain injuries and gas formations. It is advisable to conduct pmCT especially in cases without consent to

  14. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  16. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  17. Bursae and abscess cavities communicating with the hip: diagnosis using arthrography and CT

    International Nuclear Information System (INIS)

    Steinbach, L.S.; Schneider, R.; Goldman, A.B.; Kazam, E.; Ranawat, C.S.; Ghelman, B.

    1985-01-01

    Bursae or abscess cavities communicating with the hip joint were demonstrated by hip arthrography or by computed tomography (CT) in 40 cases. The bursae or abscess cavities were associated with underlying abnormalities in the hip, including painful hip prostheses, infection, and inflammatory or degenerative arthritis. Symptoms may be produced directly as a result of infection or indirectly as a result of inflammation or pressure on adjacent structures. Hip arthrography can confirm a diagnosis of bursae and abscess cavities communicating with the hip joint in patients with hip pain or soft-tissue masses around the groin. Differentiation of enlarged bursae from other abnormalities is important to avoid unnecessary or incorrect surgery

  18. Optimization of Protocol CT, PET-CT, whole body

    International Nuclear Information System (INIS)

    Gutierrez, Fredys Santos; Namias, Mauro

    2013-01-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study

  19. 10 CFR 602.15 - Indirect cost limitations.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Indirect cost limitations. 602.15 Section 602.15 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS EPIDEMIOLOGY AND OTHER HEALTH STUDIES FINANCIAL ASSISTANCE PROGRAM § 602.15 Indirect cost limitations. Awards issued under this part for conferences and...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  1. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-02-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author).

  2. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Abdomen and Pelvis Computed tomography (CT) of the abdomen and pelvis is a ... is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as a CT or CAT ...

  3. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

    Science.gov (United States)

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Theysohn, Jens; Wetter, Axel

    2018-03-28

    To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose index vol (CTDI vol ); dose-length product (DLP body ); size-specific dose estimate (SSDE)] were also compared. Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

  4. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  5. Use of a Trellis Device for Endovascular Treatment of Venous Thrombosis Involving a Duplicated Inferior Vena Cava

    Energy Technology Data Exchange (ETDEWEB)

    Saettele, Megan R., E-mail: SaetteleM@umkc.edu [University of Missouri, Kansas City, Department of Radiology, Saint Luke' s Hospital (United States); Morelli, John N., E-mail: dr.john.morelli@gmail.com [Texas A and M University Health Science Center, Department of Radiology, Scott and White Clinic and Hospital (United States); Chesis, Paul; Wible, Brandt C. [University of Missouri, Kansas City, Department of Interventional Radiology, Saint Luke' s Hospital (United States)

    2013-12-15

    Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot involving the infrarenal segment of a duplicated left IVC who underwent pharmacomechanical thrombectomy and tissue plasminogen activator catheter-directed thrombolysis with complete deep venous thrombosis resolution. To our knowledge this is the first reported case in the English literature of the use of a Trellis thrombectomy catheter in the setting of duplicated IVC.

  6. 10 CFR 605.16 - Indirect cost limitations.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Indirect cost limitations. 605.16 Section 605.16 Energy DEPARTMENT OF ENERGY (CONTINUED) ASSISTANCE REGULATIONS THE OFFICE OF ENERGY RESEARCH FINANCIAL ASSISTANCE PROGRAM § 605.16 Indirect cost limitations. Awards issued under this part for conferences and scientific...

  7. 77 FR 41899 - Indirect Food Additives: Polymers

    Science.gov (United States)

    2012-07-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 177 [Docket No. FDA-2012-F-0031] Indirect Food Additives: Polymers AGENCY: Food and Drug Administration, HHS. ACTION... CFR part 177 is amended as follows: PART 177--INDIRECT FOOD ADDITIVES: POLYMERS 0 1. The authority...

  8. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  9. Performance evaluation of the General Electric eXplore CT 120 micro-CT using the vmCT phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bahri, M.A., E-mail: M.Bahri@ulg.ac.be [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Warnock, G.; Plenevaux, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Choquet, P.; Constantinesco, A. [Biophysique et Medecine Nucleaire, Hopitaux universitaires de Strasbourg, Strasbourg (France); Salmon, E.; Luxen, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Seret, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); ULg-Liege University, Experimental Medical Imaging, Liege (Belgium)

    2011-08-21

    The eXplore CT 120 is the latest generation micro-CT from General Electric. It is equipped with a high-power tube and a flat-panel detector. It allows high resolution and high contrast fast CT scanning of small animals. The aim of this study was to compare the performance of the eXplore CT 120 with that of the eXplore Ultra, its predecessor for which the methodology using the vmCT phantom has already been described . The phantom was imaged using typical a rat (fast scan or F) or mouse (in vivo bone scan or H) scanning protocols. With the slanted edge method, a 10% modulation transfer function (MTF) was observed at 4.4 (F) and 3.9-4.4 (H) mm{sup -1} corresponding to 114 {mu}m resolution. A fairly larger MTF was obtained by the coil method with the MTF for the thinnest coil (3.3 mm{sup -1}) equal to 0.32 (F) and 0.34 (H). The geometric accuracy was better than 0.3%. There was a highly linear (R{sup 2}>0.999) relationship between measured and expected CT numbers for both the CT number accuracy and linearity sections of the phantom. A cupping effect was clearly seen on the uniform slices and the uniformity-to-noise ratio ranged from 0.52 (F) to 0.89 (H). The air CT number depended on the amount of polycarbonate surrounding the area where it was measured; a difference as high as approximately 200 HU was observed. This hindered the calibration of this scanner in HU. This is likely due to the absence of corrections for beam hardening and scatter in the reconstruction software. However in view of the high linearity of the system, the implementation of these corrections would allow a good quality calibration of the scanner in HU. In conclusion, the eXplore CT 120 achieved a better spatial resolution than the eXplore Ultra (based on previously reported specifications) and future software developments will include beam hardening and scatter corrections that will make the new generation CT scanner even more promising.

  10. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  11. Indirect inference with time series observed with error

    DEFF Research Database (Denmark)

    Rossi, Eduardo; Santucci de Magistris, Paolo

    estimation. We propose to solve this inconsistency by jointly estimating the nuisance and the structural parameters. Under standard assumptions, this estimator is consistent and asymptotically normal. A condition for the identification of ARMA plus noise is obtained. The proposed methodology is used......We analyze the properties of the indirect inference estimator when the observed series are contaminated by measurement error. We show that the indirect inference estimates are asymptotically biased when the nuisance parameters of the measurement error distribution are neglected in the indirect...... to estimate the parameters of continuous-time stochastic volatility models with auxiliary specifications based on realized volatility measures. Monte Carlo simulations shows the bias reduction of the indirect estimates obtained when the microstructure noise is explicitly modeled. Finally, an empirical...

  12. Preoperative 4D CT Localization of Nonlocalizing Parathyroid Adenomas by Ultrasound and SPECT-CT.

    Science.gov (United States)

    Hinson, Andrew M; Lee, David R; Hobbs, Bradley A; Fitzgerald, Ryan T; Bodenner, Donald L; Stack, Brendan C

    2015-11-01

    To evaluate 4-dimensional (4D) computed tomography (CT) for the localization of parathyroid adenomas previously considered nonlocalizing on ultrasound and single-photon emission CT with CT scanning (SPECT-CT). To measure radiation exposure associated with 4D-CT and compared it with SPECT-CT. Case series with chart review. University tertiary hospital. Nineteen adults with primary hyperparathyroidism who underwent preoperative 4D CT from November 2013 through July 2014 after nonlocalizing preoperative ultrasound and technetium-99m SPECT-CT scans. Sensitivity, specificity, predictive values, and accuracy of 4D CT were evaluated. Nineteen patients (16 women and 3 men) were included with a mean age of 66 years (range, 39-80 years). Mean preoperative parathyroid hormone level was 108.5 pg/mL (range, 59.3-220.9 pg/mL), and mean weight of the excised gland was 350 mg (range, 83-797 mg). 4D CT sensitivity and specificity for localization to the patient's correct side of the neck were 84.2% and 81.8%, respectively; accuracy was 82.9%. The sensitivity for localizing adenomas to the correct quadrant was 76.5% and 91.5%, respectively; accuracy was 88.2%. 4D CT radiation exposure was significantly less than the radiation associated with SPECT-CT (13.8 vs 18.4 mSv, P = 0.04). 4D CT localizes parathyroid adenomas with relatively high sensitivity and specificity and allows for the localization of some adenomas not observed on other sestamibi-based scans. 4D CT was also associated with less radiation exposure when compared with SPECT-CT based on our study protocol. 4D CT may be considered as first- or second-line imaging for localizing parathyroid adenomas in the setting of primary hyperparathyroidism. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  13. Dose reduction during CT scanning in an anthropomorphic phantom by the use of a male gonad shield.

    Science.gov (United States)

    Price, R; Halson, P; Sampson, M

    1999-05-01

    Shielding the radiosensitive gonads during X-ray exposure has been advocated for plain film radiography for many years. In the UK, gonad shields are not widely employed in routine CT scanning, possibly owing to a perceived difficulty in protecting the gonads from a multidirectional X-ray source. The increasing numbers of CT scanners in the UK, with the large doses they deliver to patients, make potential dose reduction methods an important issue. This study measures the dose reduction achievable by shielding the male gonads with a lead wrap-around protection device. The reductions in dose when shielded both from direct radiation and from indirect radiation scattered from local tissues were studied. The use of the device resulted in a statistically significant reduction in the absorbed testicular dose from both direct and scattered radiation, with no increase in the dose measured in surrounding tissues. In three clinically relevant experimental protocols where the testes were not irradiated directly, the testicular absorbed dose from indirect scatter was reduced by 77-93% of the corresponding non-shielded figure. In these three experiments, image quality was unaltered by the use of the shield. A larger dose reduction was obtained when the shield was used to protect the testes from direct irradiation. However, this was achieved at the expense of considerable image degradation from streak artefact that would effectively prevent the clinical use of the device in this setting.

  14. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  15. Long term outcomes from CT-guided indirect cervical nerve root blocks and their relationship to the MRI findings. A prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Bensler, Susanne; Sutter, Reto; Pfirrmann, Christian W.A.; Peterson, Cynthia K. [Orthopedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); University of Zurich, Faculty of Medicine, Zurich (Switzerland)

    2015-11-15

    To investigate long-term pain reduction and 'improvement' in patients with indirect cervical nerve-root-blocks in comparison to MRI findings. One hundred and twelve patients with MRI confirmed cervical radiculopathy and an indirect cervical nerve-root-block were included. Two radiologists independently evaluated the MRI examinations. 12 different MRI abnormalities at the level and side of infiltration were compared to pain relief and 'improvement' at 1-month, 3-months and 1-year post injection. The proportion of patients reporting clinically relevant 'improvement' was 36.7 % at 1-month, 53.9 % at 3-months and 68.1 % at 1-year. At 1-month post injection, a statistically significantly lower percentage of patients eventually requiring surgery reported improvement and lower NRS change scores compared to those who did not undergo surgery (p = 0.001). Patients with extrusion of the disc were around 4-times more likely to have surgery. At 1-year post-injection the presence of nerve-root compromise was significantly linked to treatment outcome (p = 0.011). Patients with nerve root compression were more likely to report improvement at 1 year. Patients with disc extrusions have less pain relief and are 4 times more likely to go to surgery than patients with disc protrusions. (orig.)

  16. Long term outcomes from CT-guided indirect cervical nerve root blocks and their relationship to the MRI findings. A prospective study

    International Nuclear Information System (INIS)

    Bensler, Susanne; Sutter, Reto; Pfirrmann, Christian W.A.; Peterson, Cynthia K.

    2015-01-01

    To investigate long-term pain reduction and 'improvement' in patients with indirect cervical nerve-root-blocks in comparison to MRI findings. One hundred and twelve patients with MRI confirmed cervical radiculopathy and an indirect cervical nerve-root-block were included. Two radiologists independently evaluated the MRI examinations. 12 different MRI abnormalities at the level and side of infiltration were compared to pain relief and 'improvement' at 1-month, 3-months and 1-year post injection. The proportion of patients reporting clinically relevant 'improvement' was 36.7 % at 1-month, 53.9 % at 3-months and 68.1 % at 1-year. At 1-month post injection, a statistically significantly lower percentage of patients eventually requiring surgery reported improvement and lower NRS change scores compared to those who did not undergo surgery (p = 0.001). Patients with extrusion of the disc were around 4-times more likely to have surgery. At 1-year post-injection the presence of nerve-root compromise was significantly linked to treatment outcome (p = 0.011). Patients with nerve root compression were more likely to report improvement at 1 year. Patients with disc extrusions have less pain relief and are 4 times more likely to go to surgery than patients with disc protrusions. (orig.)

  17. Indications for chest CT. Retrospective study of cases with normal chest CT

    International Nuclear Information System (INIS)

    Obata, Shiro

    1995-01-01

    The usefulness of computed tomography (CT) in thoracic radiology is now well appreciated, and the number of chest CTs has greatly increased. There are, however, many chest CT cases that are completely or almost completely normal. Indications for chest CT should be re-evaluated considering the cost and radiation exposure associated with the examination. Reviewing the reports of 4930 chest CT examinations performed in three hospitals during the period of two years, the author found 620 (12.6%) negative CT examinations. In 312 of the 620, the CT was requested because of 'abnormal shadow' on chest radiograph. When the same chest radiographs were re-evaluated by two radiologists, no abnormality was noted in 257 cases (82.4%). CT examinations were considered justified in only 55 cases (17.6%). There was a significant difference in the frequency of normal chest CT examinations between the university hospital and two other hospitals. The causes of false positive interpretation of chest radiographs were analyzed, and it was felt that fundamental knowledge necessary to interpret chest radiographs was lacking. The importance of close cooperation between clinicians and radiologists should be emphasized. (author)

  18. Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.

    Science.gov (United States)

    Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan

    2017-12-01

    To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.

  19. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  20. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Takenaka, Daisuke [Department of Radiology, Hyogo Cancer Center, Akashi (Japan); Fujisawa, Yasuko; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine (Japan)

    2017-01-15

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV{sub 1}. Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV{sub 1} (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  1. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  2. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-01-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  5. Indirect techniques in nuclear astrophysics

    International Nuclear Information System (INIS)

    Mukhamedzhanov, A.M.; Tribble, R.E.; Blokhintsev, L.D.; Cherubini, S.; Spitaleri, C.; Kroha, V.; Nunes, F.M.

    2005-01-01

    It is very difficult or often impossible to measure in the lab conditions nuclear cross sections at astrophysically relevant energies. That is why different indirect techniques are used to extract astrophysical information. In this talk different experimental possibilities to get astrophysical information using radioactive and stable beams will be addressed. 1. The asymptotic normalization coefficient (ANC) method. 2. Radiative neutron captures are determined by the spectroscopic factors (SP). A new experimental technique to determine the neutron SPs will be addressed. 3. 'Trojan Horse' is another unique indirect method, which allows one to extract the astrophysical factors for direct and resonant nuclear reactions at astrophysically relevant energies. (author)

  6. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  7. Indirect Taxes in Romania – an Econometric Analysis

    Directory of Open Access Journals (Sweden)

    Daniela Penu

    2016-03-01

    Full Text Available Indirect taxes have a significant weight in the GDP. Statistical data reveals that the new states that joined the EU in its funding sources to the greatest extent through indirect taxes. They reveal, on the one hand, reducing the tax burden on the producer, and on the other hand, the difficulty faced by the country in direct tax collection, but also some problems of social nature. This article proposes an econometric analysis of the relationship between indirect taxes and household final consumption expenditure.

  8. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  9. The power of indirect social ties

    OpenAIRE

    Zuo, Xiang; Blackburn, Jeremy; Kourtellis, Nicolas; Skvoretz, John; Iamnitchi, Adriana

    2014-01-01

    While direct social ties have been intensely studied in the context of computer-mediated social networks, indirect ties (e.g., friends of friends) have seen little attention. Yet in real life, we often rely on friends of our friends for recommendations (of good doctors, good schools, or good babysitters), for introduction to a new job opportunity, and for many other occasional needs. In this work we attempt to 1) quantify the strength of indirect social ties, 2) validate it, and 3) empiricall...

  10. Two distinct neural mechanisms underlying indirect reciprocity.

    Science.gov (United States)

    Watanabe, Takamitsu; Takezawa, Masanori; Nakawake, Yo; Kunimatsu, Akira; Yamasue, Hidenori; Nakamura, Mitsuhiro; Miyashita, Yasushi; Masuda, Naoki

    2014-03-18

    Cooperation is a hallmark of human society. Humans often cooperate with strangers even if they will not meet each other again. This so-called indirect reciprocity enables large-scale cooperation among nonkin and can occur based on a reputation mechanism or as a succession of pay-it-forward behavior. Here, we provide the functional and anatomical neural evidence for two distinct mechanisms governing the two types of indirect reciprocity. Cooperation occurring as reputation-based reciprocity specifically recruited the precuneus, a region associated with self-centered cognition. During such cooperative behavior, the precuneus was functionally connected with the caudate, a region linking rewards to behavior. Furthermore, the precuneus of a cooperative subject had a strong resting-state functional connectivity (rsFC) with the caudate and a large gray matter volume. In contrast, pay-it-forward reciprocity recruited the anterior insula (AI), a brain region associated with affective empathy. The AI was functionally connected with the caudate during cooperation occurring as pay-it-forward reciprocity, and its gray matter volume and rsFC with the caudate predicted the tendency of such cooperation. The revealed difference is consistent with the existing results of evolutionary game theory: although reputation-based indirect reciprocity robustly evolves as a self-interested behavior in theory, pay-it-forward indirect reciprocity does not on its own. The present study provides neural mechanisms underlying indirect reciprocity and suggests that pay-it-forward reciprocity may not occur as myopic profit maximization but elicit emotional rewards.

  11. Indirect effects in community ecology: Their definition, study and importance.

    Science.gov (United States)

    Strauss, S Y

    1991-07-01

    The diversity of indirect interactions that can occur within communities is large. Recent research on indirect interactions is scattered in the literature under numerous labels. The definition of indirect effects is an important aspect of their study, and clarifies some of the subtle differences among indirect effects found in natural communities. Choosing which species to study, how to manipulate species and for what duration, which attributes to measure and, finally, which analytical techniques to use are all problems facing the community ecologist. Ultimately, we are striving for the best means of determining the relative importance of direct and indirect effects in structuring communities. Copyright © 1991. Published by Elsevier Ltd.

  12. Preschool children's behavioral tendency toward social indirect reciprocity.

    Directory of Open Access Journals (Sweden)

    Mayuko Kato-Shimizu

    Full Text Available Social indirect reciprocity seems to be crucial in enabling large-scale cooperative networks among genetically unrelated individuals in humans. However, there are relatively few studies on social indirect reciprocity in children compared to adults. Investigating whether young children have a behavioral tendency toward social indirect reciprocity will help us understand how and when the fundamental ability to form cooperative relationships among adults is acquired. Using naturalistic observation at a nursery school, this study examined whether 5- to 6-year-olds show a behavioral tendency to engage in social indirect reciprocity in response to their peers' prosocial behavior toward a third party. The results revealed that bystander children tended to display prosocial behavior toward their peers more frequently after observing these peers' prosocial behavior toward third-party peers, compared with control situations; this suggests that 5- to 6-year-olds may have an essential behavioral tendency to establish social indirect reciprocity when interacting with peers in their daily lives. In addition, bystanders tended to display affiliative behavior after observing focal children's prosocial behavior. In other words, observing peers' prosocial behavior toward third-party peers evoked bystanders' positive emotions toward the helpers. Considering both the present results and previous findings, we speculate that in preschoolers, such positive emotions might mediate the increase in the bystander's prosocial behavior toward the helper. In addition, an intuitional emotional process plays an important role in the preschooler's behavioral tendency toward social indirect reciprocity in natural interactions with peers.

  13. Preschool children's behavioral tendency toward social indirect reciprocity.

    Science.gov (United States)

    Kato-Shimizu, Mayuko; Onishi, Kenji; Kanazawa, Tadahiro; Hinobayashi, Toshihiko

    2013-01-01

    Social indirect reciprocity seems to be crucial in enabling large-scale cooperative networks among genetically unrelated individuals in humans. However, there are relatively few studies on social indirect reciprocity in children compared to adults. Investigating whether young children have a behavioral tendency toward social indirect reciprocity will help us understand how and when the fundamental ability to form cooperative relationships among adults is acquired. Using naturalistic observation at a nursery school, this study examined whether 5- to 6-year-olds show a behavioral tendency to engage in social indirect reciprocity in response to their peers' prosocial behavior toward a third party. The results revealed that bystander children tended to display prosocial behavior toward their peers more frequently after observing these peers' prosocial behavior toward third-party peers, compared with control situations; this suggests that 5- to 6-year-olds may have an essential behavioral tendency to establish social indirect reciprocity when interacting with peers in their daily lives. In addition, bystanders tended to display affiliative behavior after observing focal children's prosocial behavior. In other words, observing peers' prosocial behavior toward third-party peers evoked bystanders' positive emotions toward the helpers. Considering both the present results and previous findings, we speculate that in preschoolers, such positive emotions might mediate the increase in the bystander's prosocial behavior toward the helper. In addition, an intuitional emotional process plays an important role in the preschooler's behavioral tendency toward social indirect reciprocity in natural interactions with peers.

  14. Separating astrophysical sources from indirect dark matter signals

    Science.gov (United States)

    Siegal-Gaskins, Jennifer M.

    2015-01-01

    Indirect searches for products of dark matter annihilation and decay face the challenge of identifying an uncertain and subdominant signal in the presence of uncertain backgrounds. Two valuable approaches to this problem are (i) using analysis methods which take advantage of different features in the energy spectrum and angular distribution of the signal and backgrounds and (ii) more accurately characterizing backgrounds, which allows for more robust identification of possible signals. These two approaches are complementary and can be significantly strengthened when used together. I review the status of indirect searches with gamma rays using two promising targets, the Inner Galaxy and the isotropic gamma-ray background. For both targets, uncertainties in the properties of backgrounds are a major limitation to the sensitivity of indirect searches. I then highlight approaches which can enhance the sensitivity of indirect searches using these targets. PMID:25304638

  15. CT and MR imaging of the kidney and adrenal glands: CT of the kidney

    International Nuclear Information System (INIS)

    Levine, E.

    1987-01-01

    Because of its high diagnostic yield, safety, and cost-effectiveness, CT has become a major imaging technique for evaluating the kidney. CT is highly accurate for determining the nature and extent of renal masses, and this has become the main indication for renal CT. However, CT is also valuable in assessing patients with renal cystic disease, trauma, inflammatory disease, infarction, hemorrhage and hydronephrosis of unknown cause. This presentation reviews the normal CT anatomy of the kidneys and the usefulness of CT in the diagnosis of all these conditions. Examination techniques are discussed with particular emphasis on avoiding diagnostic pitfalls and tailoring the examination to the nature of the clinical problem. CT findings in various renal disorders are compared with those of other imaging techniques, particularly US and angiography, and the place of CT in the diagnostic approach to these disorders is considered

  16. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    Science.gov (United States)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  17. Deep venous thrombophlebitis: detection with 4-hour versus 24-hour platelet scintigraphy

    International Nuclear Information System (INIS)

    Seabold, J.E.; Conrad, G.R.; Ponto, J.A.; Kimball, D.A.; Frey, E.E.; Ahmed, F.; Coughlan, J.D.; Jensen, K.C.

    1987-01-01

    Thirty-one nonheparinized patients with suspected deep venous thrombophlebitis (DVT) underwent contrast venography and indium-111 platelet scintigraphy (In-111 PS). Venography permitted identification of acute DVT in 12 of 31 cases (39%). One additional patient was considered to have acute DVT despite nonconclusive venography results. In-111 PS results were positive at 4 hours in nine of 13 cases (69%) and at 24 hours in 12 of 13 cases (92%). Two of four patients with false-negative 4-hour In-111 PS studies had received warfarin. Thus, the sensitivity of 4-hour In-111 PS in patients not receiving anticoagulants was 82%. Venography results were negative for acute DVT in 18 cases, and 4-hour In-111 PS studies were negative or equivocal in each. In-111 PS is an alternative to contrast venography for detecting acute DVT. If 4-hour In-111 PS results are positive, anticoagulation can be initiated. Delayed images are necessary if the 4-hour images are negative or equivocal

  18. Indirect search for dark matter with AMS

    International Nuclear Information System (INIS)

    Goy, Corinne

    2006-01-01

    This document summarises the potential of AMS in the indirect search for Dark Matter. Observations and cosmology indicate that the Universe may include a large amount of Dark Matter of unknown nature. A good candidate is the Ligthest Supersymmetric Particle in R-Parity conserving models. AMS offers a unique opportunity to study Dark Matter indirect signature in three spectra: gamma, antiprotons and positrons

  19. A modified VMAT adaptive radiotherapy for nasopharyngeal cancer patients based on CT-CT image fusion

    International Nuclear Information System (INIS)

    Jin, Xiance; Han, Ce; Zhou, Yongqiang; Yi, Jinling; Yan, Huawei; Xie, Congying

    2013-01-01

    To investigate the feasibility and benefits of a modified adaptive radiotherapy (ART) by replanning in the initial CT (iCT) with new contours from a repeat CT (rCT) based on CT-CT image fusion for nasopharyngeal cancer (NPC) patients underwent volumetric modulated arc radiotherapy (VMAT). Nine NPC patients underwent VMAT treatment with a rCT at 23rd fraction were enrolled in this study. Dosimetric differences for replanning VMAT plans in the iCT and in the rCT were compared. Volumetric and dosimetric changes of gross tumor volume (GTV) and organs at risk (OARs) of this modified ART were also investigated. No dosimetric differences between replanning in the iCT and in the rCT were observed. The average volume of GTV decreased from 78.83 ± 38.42 cm 3 in the iCT to 71.44 ± 37.46 cm 3 in the rCT, but with no significant difference (p = 0.42).The average volume of the left and right parotid decreased from 19.91 ± 4.89 cm 3 and 21.58 ± 6.16 cm 3 in the iCT to 11.80 ± 2.79 cm 3 and 13.29 ± 4.17 cm 3 in the rCT (both p < 0.01), respectively. The volume of other OARs did not shrink very much. No significant differences on PTV GTV and PTV CTV coverage were observed for replanning with this modified ART. Compared to the initial plans, the average mean dose of the left and right parotid after re-optimization were decreased by 62.5 cGy (p = 0.05) and 67.3 cGy (p = 0.02), respectively, and the V5 (the volume receiving 5 Gy) of the left and right parotids were decreased by 7.8% (p = 0.01) and 11.2% (p = 0.001), respectively. There was no significant difference on the dose delivered to other OARs. Patients with NPC undergoing VMAT have significant anatomic and dosimetric changes to parotids. Repeat CT as an anatomic changes reference and re-optimization in the iCT based on CT-CT image fusion was accurate enough to identify the volume changes and to ensure safe dose to parotids

  20. A review of Indirect Matrix Converter Topologies

    Directory of Open Access Journals (Sweden)

    Salem Rahmani

    2015-08-01

    Full Text Available Abstract—Matrix Converter (MC is a modern direct AC/AC electrical power converter without dc-link capacitor. MC is operated in four quadrant, assuring a control of the output voltage, amplitude and frequency. The matrix converter has recently attracted significant attention among researchers and it has become increasing attractive for applications of wind energy conversion, military power supplies, induction motor drives, etc. Recently, different MC topologies have been proposed and developed which have their own advantages and disadvantages. Matrix converter can be classified as direct and indirect structures. The direct one has been elaborated in previous work. In this paper the indirect MCs are reviewed. Different characteristics of the indirect MC topologies are mentioned to show the strengths and weaknesses of such converter topologies.

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  4. Indirect Control for Demand Side Management – A Conceptual Introduction

    DEFF Research Database (Denmark)

    Heussen, Kai; You, Shi; Biegel, Benjamin

    2012-01-01

    The concept of “indirect control” has become a relevant discussion term in relation to activation distributed and small-scale demand and generation units to provide resources for power system balancing. The term and its association with price signals has, however caused some confusion as to its...... correct definition, either as a control or a market concept. This paper aims to provide a conceptual introduction to "indirect control" for management of small and distributed demand side resources. A review of control concepts and an analysis of "indirectness" features are provided to create a framework...... for systematic classification of indirect control strategies. The concepts developed then enable a discussion of control performance and valuation of direct- and indirect control strategies....

  5. The Influence of Direct and Indirect Speech on Source Memory

    Directory of Open Access Journals (Sweden)

    Anita Eerland

    2018-02-01

    Full Text Available People perceive the same situation described in direct speech (e.g., John said, “I like the food at this restaurant” as more vivid and perceptually engaging than described in indirect speech (e.g., John said that he likes the food at the restaurant. So, if direct speech enhances the perception of vividness relative to indirect speech, what are the effects of using indirect speech? In four experiments, we examined whether the use of direct and indirect speech influences the comprehender’s memory for the identity of the speaker. Participants read a direct or an indirect speech version of a story and then addressed statements to one of the four protagonists of the story in a memory task. We found better source memory at the level of protagonist gender after indirect than direct speech (Exp. 1–3. When the story was rewritten to make the protagonists more distinctive, we also found an effect of speech type on source memory at the level of the individual, with better memory after indirect than direct speech (Exp. 3–4. Memory for the content of the story, however, was not influenced by speech type (Exp. 4. While previous research showed that direct speech may enhance memory for how something was said, we conclude that indirect speech enhances memory for who said what.

  6. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  7. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  8. Postoperative CT in pancreas transplantation

    International Nuclear Information System (INIS)

    Powell, F.E.; Harper, S.J.F.; Callaghan, C.J.; Shaw, A.; Godfrey, E.M.; Bradley, J.A.; Watson, C.J.E.; Pettigrew, G.J.

    2015-01-01

    Aim: To examine the usage and value of computed tomography (CT) following simultaneous pancreas and kidney (SPK) transplantation. Materials and methods: Indications for postoperative CT, key findings, and their influence on management were determined by retrospective analysis. Results: Ninety-eight patients underwent 313 CT examinations. Common indications for the examinations included suspected intra-abdominal collection (31.1%) and elevated serum amylase/lipase (24.1%). CT findings most frequently showed non-specific mild inflammation (27.6%), a normal scan (17.1%) and fluid collections (16.3%). High capillary blood glucose (CBG) was associated with resultant CT demonstration of graft vascular abnormalities, but otherwise, particular clinical indications were not associated with specific CT findings. Conclusion: Clinical findings in patients with SPK transplants are non-specific. The pattern of abnormalities encountered is significantly different to those seen in native pancreatic disease and demands a tailored protocol. CT enables accurate depiction of vascular abnormalities and fluid collections, thus reducing the number of surgical interventions that might otherwise be required. Elevated CBG should prompt urgent CT to exclude potentially reversible vascular complications. - Highlights: • The value of CT following simultaneous pancreas and kidney transplantation was assessed. • 313 CT scans were performed on 98 patients between January 2005 and August 2010. • Elevated blood glucose was associated with CT findings of graft vascular anomalities. • CT was particularly useful in directing operative versus non-operative intervention.

  9. Spinal CT scan, 2

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival. (Chiba, N.)

  10. Analysis of the association between periportal low attenuation, as seen on CT, after blunt abdominal trauma, and elevated central venous pressure

    International Nuclear Information System (INIS)

    Lee, Jae Hung; Lee, Hyeon Kyeong; Lee, Chae Kyeong; Ku, Kwan Min; Lee, Sung Woo; Kim, Miu Woon; Ahn, Woo Sub; Yoon, Ji Young

    1999-01-01

    To assess the causes of periportal low attenuation, as seen on CT, in patients with blunt abdominal trauma. From among 812 patients who underwent abdominal CT after blunt abdominal trauma, we retrospectively analysed the findings in 124 with evidence of periportal low attenuation. Among these, hepatic injury was noted in only 87. The presence or absence, and extent of hepatic injury, and of periportal low attenuation, as seen on CT, were carefully evaluated. In each case, the ratio of the transverse diameter of the inferior vena cava(IVC) to the aorta at the level of the right adrenal gland provided an indirect measurement of central venous pressure ; for control purposes, the ratio was also obtained in 21 non-traumatic patients with no abnormal abdominal CT findings. Of the 87 patients with hepatic injury, 46 showed no periportal low attenuation, and average value of the ratio between the IVC and aorta was 1.16±0.12, while the remaining 41 patients showed periportal low attenuation with a ratio of 1.51±0.21(p<0.05). In the 37 patients with periportal low attenuation but no evidence of concomitant hepatic injury, the average ratio was 1.52±0.25, while in 21 non-traumatic patients it was 1.15±0.16. For resuscitation, all patients had received 0.5-5.0 litre of IV fluid therapy before CT, and at the time of CT, were normotensive. Rapidly elevated central venous pressure following massive IV infusion therapy in patients with blunt abdominal trauma can be one of the causes of periportal low attenuation, as seen on CT

  11. Analysis of the association between periportal low attenuation, as seen on CT, after blunt abdominal trauma, and elevated central venous pressure

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hung; Lee, Hyeon Kyeong; Lee, Chae Kyeong; Ku, Kwan Min; Lee, Sung Woo; Kim, Miu Woon; Ahn, Woo Sub [Dongguk Univ. College of Medicine, Pohang (Korea, Republic of); Yoon, Ji Young [Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-01-01

    To assess the causes of periportal low attenuation, as seen on CT, in patients with blunt abdominal trauma. From among 812 patients who underwent abdominal CT after blunt abdominal trauma, we retrospectively analysed the findings in 124 with evidence of periportal low attenuation. Among these, hepatic injury was noted in only 87. The presence or absence, and extent of hepatic injury, and of periportal low attenuation, as seen on CT, were carefully evaluated. In each case, the ratio of the transverse diameter of the inferior vena cava(IVC) to the aorta at the level of the right adrenal gland provided an indirect measurement of central venous pressure ; for control purposes, the ratio was also obtained in 21 non-traumatic patients with no abnormal abdominal CT findings. Of the 87 patients with hepatic injury, 46 showed no periportal low attenuation, and average value of the ratio between the IVC and aorta was 1.16{+-}0.12, while the remaining 41 patients showed periportal low attenuation with a ratio of 1.51{+-}0.21(p<0.05). In the 37 patients with periportal low attenuation but no evidence of concomitant hepatic injury, the average ratio was 1.52{+-}0.25, while in 21 non-traumatic patients it was 1.15{+-}0.16. For resuscitation, all patients had received 0.5-5.0 litre of IV fluid therapy before CT, and at the time of CT, were normotensive. Rapidly elevated central venous pressure following massive IV infusion therapy in patients with blunt abdominal trauma can be one of the causes of periportal low attenuation, as seen on CT.

  12. Indirect reciprocity and the evolution of "moral signals"

    Science.gov (United States)

    Smead, Rory

    2010-01-01

    Signals regarding the behavior of others are an essential element of human moral systems and there are important evolutionary connections between language and large-scale cooperation. In particular, social communication may be required for the reputation tracking needed to stabilize indirect reciprocity. Additionally, scholars have suggested that the benefits of indirect reciprocity may have been important for the evolution of language and that social signals may have coevolved with large-scale cooperation. This paper investigates the possibility of such a coevolution. Using the tools of evolutionary game theory, we present a model that incorporates primitive "moral signaling" into a simple setting of indirect reciprocity. This model reveals some potential difficulties for the evolution of "moral signals." We find that it is possible for "moral signals" to evolve alongside indirect reciprocity, but without some external pressure aiding the evolution of a signaling system, such a coevolution is unlikely.

  13. Indirect self-destructiveness in individuals with schizophrenia

    Directory of Open Access Journals (Sweden)

    Konstantinos Tsirigotis

    2017-06-01

    Full Text Available Objective: To explore the indirect self-destructiveness syndrome in patients with schizophrenia. Methods: Two hundred individuals with paranoid schizophrenia (117 men and 83 women, mean age 37.15 years, all in remission, were examined using the Polish version of the Chronic Self-Destructiveness Scale. Two hundred well-matched healthy individuals served as a control group. Results: The intensity of indirect self-destructiveness was greater in the schizophrenia group than in controls. The intensity of each manifestation was as follows (in decreasing order: helplessness and passiveness in the face of difficulties (A5, personal and social neglects (A3, lack of planfulness (A4, poor health maintenance (A2, transgression and risk (A1. Conclusion: Patients with schizophrenia displayed more behaviors that were indirectly self-destructive than healthy controls; they scored better than healthy controls only on caring for their own health. The patients showed the lowest intensity of behaviors connected with the active form of indirect self-destructiveness, and the highest intensity of behaviors connected with the passive form. These findings may enable delivery of more effective forms of pharmacological and psychosocial help to patients with schizophrenia.

  14. Epidemic spreading through direct and indirect interactions.

    Science.gov (United States)

    Ganguly, Niloy; Krueger, Tyll; Mukherjee, Animesh; Saha, Sudipta

    2014-09-01

    In this paper we study the susceptible-infected-susceptible epidemic dynamics, considering a specialized setting where popular places (termed passive entities) are visited by agents (termed active entities). We consider two types of spreading dynamics: direct spreading, where the active entities infect each other while visiting the passive entities, and indirect spreading, where the passive entities act as carriers and the infection is spread via them. We investigate in particular the effect of selection strategy, i.e., the way passive entities are chosen, in the spread of epidemics. We introduce a mathematical framework to study the effect of an arbitrary selection strategy and derive formulas for prevalence, extinction probabilities, and epidemic thresholds for both indirect and direct spreading. We also obtain a very simple relationship between the extinction probability and the prevalence. We pay special attention to preferential selection and derive exact formulas. The analysis reveals that an increase in the diversity in the selection process lowers the epidemic thresholds. Comparing the direct and indirect spreading, we identify regions in the parameter space where the prevalence of the indirect spreading is higher than the direct one.

  15. An indecent proposal: the dual functions of indirect speech.

    Science.gov (United States)

    Chakroff, Aleksandr; Thomas, Kyle A; Haque, Omar S; Young, Liane

    2015-01-01

    People often use indirect speech, for example, when trying to bribe a police officer by asking whether there might be "a way to take care of things without all the paperwork." Recent game theoretic accounts suggest that a speaker uses indirect speech to reduce public accountability for socially risky behaviors. The present studies examine a secondary function of indirect speech use: increasing the perceived moral permissibility of an action. Participants report that indirect speech is associated with reduced accountability for unethical behavior, as well as increased moral permissibility and increased likelihood of unethical behavior. Importantly, moral permissibility was a stronger mediator of the effect of indirect speech on likelihood of action, for judgments of one's own versus others' unethical action. In sum, the motorist who bribes the police officer with winks and nudges may not only avoid public punishment but also maintain the sense that his actions are morally permissible. Copyright © 2014 Cognitive Science Society, Inc.

  16. CT manifestations of liver abscess

    International Nuclear Information System (INIS)

    Yan Jianfeng; Peng Yongjun

    2006-01-01

    Objective: To study CT findings of hepatic abscess. Methods: CT findings and clinical materials of 38 patients with liver abscess verified by aspiration were retrospectively viewed. All patients were examined by non-enhanced and contrast enhanced CT. Results: In 25 cases, inhomogeneous hypodense lesions with unclear demarcation were found on non-enhanced CT. On contrast enhanced CT scan, target or cluster enhancement was found Additionally, air was found within some lesions. In the rest 13 cases with early stage liver abscess, no typical sign was found on non-enhanced CT, while rosette sign and continued enhancement sign were demonstrated after the contrast agent was given. Conclusion: Various CT findings are found in different stages of liver abscess. The diagnosis and differential diagnosis should be based on CT manifestations and clinical history as well. (authors)

  17. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  18. CT of the knee

    International Nuclear Information System (INIS)

    Ghelman, B.

    1987-01-01

    CT can be combined with arthrography of the knee to study the following abnormalities: meniscal tears and cysts, synovial plicae, chondromalacia patellae, and osteochondritis dissecans. The CT-arthrogram images present abnormalities in a manner that resembles the ''in situ'' surgical findings, allowing management decisions to be made with greater confidence. The CT techniques for imaging the knee after arthrography are discussed, as is the use of plain CT

  19. Indirect techniques in nuclear astrophysics: a review

    International Nuclear Information System (INIS)

    Tribble, R E; Mukhamedzhanov, A M; Bertulani, C A; Cognata, M La; Spitaleri, C

    2014-01-01

    In this review, we discuss the present status of three indirect techniques that are used to determine reaction rates for stellar burning processes, asymptotic normalization coefficients, the Trojan Horse method and Coulomb dissociation. A comprehensive review of the theory behind each of these techniques is presented. This is followed by an overview of the experiments that have been carried out using these indirect approaches. (review article)

  20. Indirect techniques in nuclear astrophysics: a review.

    Science.gov (United States)

    Tribble, R E; Bertulani, C A; Cognata, M La; Mukhamedzhanov, A M; Spitaleri, C

    2014-10-01

    In this review, we discuss the present status of three indirect techniques that are used to determine reaction rates for stellar burning processes, asymptotic normalization coefficients, the Trojan Horse method and Coulomb dissociation. A comprehensive review of the theory behind each of these techniques is presented. This is followed by an overview of the experiments that have been carried out using these indirect approaches.

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  3. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  4. The Indirect cost of illness in Africa

    Directory of Open Access Journals (Sweden)

    Joses Muthuri Kirigia

    2018-06-01

    Full Text Available Background: The current study estimated (a the indirect costs associated with non-fatal disability and premature death across a wide range of diseases and health conditions in Africa in 2015 and (b the potential savings that could be accrued if countries were to meet the 3 health targets of the substainable development goal (SDG compared to the costs under the status quo. Methods: This study used the lost output or human capital approach to quantify the gross domestic product (GDP losses associated with the disability-adjusted-life-years (DALYs lost due to all causes by age group as well as by country economic classification (Group 1: 10 high/upper-middle income countries; Group 2: 17 lower-middle income countries; and Group 3: 27 low income countries. Results: The expected indirect cost of the 704,765,879 DALYs lost in Africa in 2015 was Int$ 2,983,187,560,197. Of this amount, 25.17%, 57.84% and 16.99% were incurred by the economies of the countries comprising Group 1, Group 2 and Group 3, respectively. Of the total continental indirect cost, 36.9%, 10.5%, 13.7%, 17.0%, 7.6%, 6.8% and 7.5% were associated with people aged 0-4, 5-14, 15-29, 30-49, 50-59, 60-69 and 70 years or older, respectively. Most of the total indirect cost (56.61% was attributable to maternal conditions, AIDS, tuberculosis (TB, malaria, neglected tropicald diseases (NTDs, non-communicable diseases and traffic injuries. Approximately half (47% of this cost could be avoided (or saved every year if the 3 (health targets of the SDG were fully met. Conclusion: The study estimated the total indirect cost of illness due to all causes by age group and country economic classification. The annual indirect cost is substantial. The findings contained in this paper suggest that health system strengthening should focus on both rich and poor countries, people of all ages and specific disease categories.

  5. Selection for components of complex characteristics - indirect selection

    International Nuclear Information System (INIS)

    Haensel, H.

    1984-01-01

    A hierarchy of complexity exists in plant characteristics. The efficiency of indirect selection for a complex characteristic by a sub-trait depends on the heritability of the complex characteristic (hsub(c)), the heritability of the sub-trait (hsub(s)), and the genotypic correlation between sub-trait and complex characteristic (rsub(s.c)). In 1961 hsub(s)Xrsub(s.c)>hsub(c) was postulated, when indirect selection becomes more efficient than direct selection. Numerical examples for this relationship are given and a table for indirect selection for yield in wheat is elaborated. Efficiency ranking of sub-traits in indirect selection may change with climate, conditions of cultivation, the level of other sub-traits, the level of the complex characteristic already reached by breeding, and the breeding material. An example shows that regression analysis for different sub-traits on the same complex characteristic, and an estimation of the differences of the within - and the between - variety slopes, may help to select the more efficient sub-trait. In another example, where simultaneous selection was made for two polygenic characteristics, one directly and the other indirectly by two sub-traits, less than half the F 5 -lines had to be continued, when using the more efficient sub-trait. (author)

  6. Indirect reciprocity in three types of social dilemmas.

    Science.gov (United States)

    Nakamura, Mitsuhiro; Ohtsuki, Hisashi

    2014-08-21

    Indirect reciprocity is a key mechanism for the evolution of human cooperation. Previous studies explored indirect reciprocity in the so-called donation game, a special class of Prisoner's Dilemma (PD) with unilateral decision making. A more general class of social dilemmas includes Snowdrift (SG), Stag Hunt (SH), and PD games, where two players perform actions simultaneously. In these simultaneous-move games, moral assessments need to be more complex; for example, how should we evaluate defection against an ill-reputed, but now cooperative, player? We examined indirect reciprocity in the three social dilemmas and identified twelve successful social norms for moral assessments. These successful norms have different principles in different dilemmas for suppressing cheaters. To suppress defectors, any defection against good players is prohibited in SG and PD, whereas defection against good players may be allowed in SH. To suppress unconditional cooperators, who help anyone and thereby indirectly contribute to jeopardizing indirect reciprocity, we found two mechanisms: indiscrimination between actions toward bad players (feasible in SG and PD) or punishment for cooperation with bad players (effective in any social dilemma). Moreover, we discovered that social norms that unfairly favor reciprocators enhance robustness of cooperation in SH, whereby reciprocators never lose their good reputation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. On the comprehensibility and perceived privacy protection of indirect questioning techniques.

    Science.gov (United States)

    Hoffmann, Adrian; Waubert de Puiseau, Berenike; Schmidt, Alexander F; Musch, Jochen

    2017-08-01

    On surveys that assess sensitive personal attributes, indirect questioning aims at increasing respondents' willingness to answer truthfully by protecting confidentiality. However, the assumption that subjects understand questioning procedures fully and trust them to protect their privacy is rarely tested. In a scenario-based design, we compared four indirect questioning procedures in terms of their comprehensibility and perceived privacy protection. All indirect questioning techniques were found to be less comprehensible by respondents than a conventional direct question used for comparison. Less-educated respondents experienced more difficulties when confronted with any indirect questioning technique. Regardless of education, the crosswise model was found to be the most comprehensible among the four indirect methods. Indirect questioning in general was perceived to increase privacy protection in comparison to a direct question. Unexpectedly, comprehension and perceived privacy protection did not correlate. We recommend assessing these factors separately in future evaluations of indirect questioning.

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  9. Self-taught axillary vein access without venography for pacemaker implantation: prospective randomized comparison with the cephalic vein access.

    Science.gov (United States)

    Squara, Fabien; Tomi, Julien; Scarlatti, Didier; Theodore, Guillaume; Moceri, Pamela; Ferrari, Emile

    2017-12-01

    Axillary vein access for pacemaker implantation is uncommon in many centres because of the lack of training in this technique. We assessed whether the introduction of the axillary vein technique was safe and efficient as compared with cephalic vein access, in a centre where no operators had any previous experience in axillary vein puncture. Patients undergoing pacemaker implantation were randomized to axillary or cephalic vein access. All three operators had no experience nor training in axillary vein puncture, and self-learned the technique by reading a published review. Axillary vein puncture was fluoroscopy-guided without contrast venography. Cephalic access was performed by dissection of delto-pectoral groove. Venous access success, venous access duration (from skin incision to guidewire or lead in superior vena cava), procedure duration, X-ray exposure, and peri-procedural (1 month) complications were recorded. results We randomized 74 consecutive patients to axillary (n = 37) or cephalic vein access (n = 37). Axillary vein was successfully accessed in 30/37 (81.1%) patients vs. 28/37 (75.7%) of cephalic veins (P = 0.57). Venous access time was shorter in axillary group than in cephalic group [5.7 (4.4-8.3) vs. 12.2 (10.5-14.8) min, P < 0.001], as well as procedure duration [34.8 (30.6-38.4) vs. 42.0 (39.1-46.6) min, P = 0.043]. X-ray exposure and peri-procedural overall complications were comparable in both groups. Axillary puncture was safe and faster than cephalic access even for the five first procedures performed by each operator. Self-taught axillary vein puncture for pacemaker implantation seems immediately safe and faster than cephalic vein access, when performed by electrophysiologists trained to pacemaker implantation but not to axillary vein puncture. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  10. CT after transsphenoidal surgery

    International Nuclear Information System (INIS)

    Tazawa, Satoru

    1991-01-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author)

  11. CT after transsphenoidal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Tazawa, Satoru [Tohoku Univ., Sendai (Japan). School of Medicine

    1991-03-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author).

  12. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  13. Evaluation of CT in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Norio; Miura, Yukio; Ohnishi, Mitsunori; Kamikon-ya, Norihiko; Sakamoto, Yoshisato; Miura, Takashi; Sakamoto, Kiyoshi; Takayasu, Yoshio

    1985-06-01

    In order to evaluate the diagnostic ability of CT in hepatocellular carcinoma, four kinds of CT images were comparatively studied by the accuracy and ROC (receiver operating characteristic) curve analysis. As a result, it was clarified that CT images were evaluated more objectively by ROC curve analysis than by accuracy. The diagnostic ability of existence and differentiation of tumor in the liver were higher in order of plain CT, contrast enhanced CT (CECT), bolus CT and CT arteriography (CTA). Therefore, in an usual CT examination intended to make differential diagnosis in space occupying liver disease, bolus CT seems to be indispensable, and also CTA is essential where diagnosis is difficult even by bolus CT.

  14. Tipping and Concentration in Markets with Indirect Network Effects

    OpenAIRE

    Jean-Pierre H. Dubé; Günter J. Hitsch; Pradeep K. Chintagunta

    2010-01-01

    This paper develops a framework for measuring “tipping”—the increase in a firm's market share dominance caused by indirect network effects. Our measure compares the expected concentration in a market to the hypothetical expected concentration that would arise in the absence of indirect network effects. In practice, this measure requires a model that can predict the counterfactual market concentration under different parameter values capturing the strength of indirect network effects. We build...

  15. Low-dose Dental-CT

    International Nuclear Information System (INIS)

    Gahleitner, A.; Imhof, H.; Homolka, P.; Fuerhauser, R.; Freudenthaler, J.; Watzek, G.

    2000-01-01

    Dental-CT is a relatively new, increasingly used investigation technique in dental radiology. Several authors have stated that the indication for Dental-CT has to be chosen on a strict basis, due to high dose values. This article describes the technique of performing dental-CT and calculates the effective dose based on published data and own measurements as well as the dose reduction potential to achieve an optimized protocol for Dental-CT investigations. (orig.) [de

  16. The Adoption of Indirect Instruments of Monetary Policy

    OpenAIRE

    Tomás J. T. Baliño; Charles Enoch; William E. Alexander

    1995-01-01

    This paper examines the experience of implementing indirect instruments of monetary policy. The experiences of country studies illustrate the variety of circumstances under which indirect instruments of monetary policy have been introduced. Case Studies are presented for Chile, Egypt, Ghana, Indonesia, Mexico, New Zealand, and Poland.

  17. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    International Nuclear Information System (INIS)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun; Pan Tinsu

    2008-01-01

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACT from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma (γ) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass γ criteria

  18. CT pelvimetry

    International Nuclear Information System (INIS)

    Vicens, J.L.; Charles, G.; Le Berre, J.; Flageat, J.

    1989-01-01

    Pelvimetry aims at providing the obstetrician with information on the size and morphology of the female pelvis, thus enabling him to assess the obstetrical prognosis as accurately as possible. Computed tomography (CT) has several advantages, in particular the lower mother and fetus radiation dose. After a brief description of obstetrical anatomy, the usual CT exploration method is presented and its results are considered in terms of measurements, indices and morphological findings. If performed with a very strict exploration procedure, CT pelvimetry is a very reliable, fact and comfortable method of examination. All these advantages, combined with the minimized patient dose, should lead to an increasingly widespread use of this technique [fr

  19. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. CT-based postimplant dosimetry of prostate brachytherapy. Comparison of 1-mm and 5-mm section CT

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Kanematsu, Masayuki; Matsuo, Masayuki; Hoshi, Hiroaki; Nakano, Masahiro; Maeda, Sanaho; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V 100 (percent of the prostate volume receiving at least the full prescribed dose), and prostate D 90 (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. The mean ±1 standard deviation (SD) postimplant pVol was 20.17±6.66 cc by 1-mm section CT and 22.24±8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P 100 was 80.44%±7.06% by 1-mm section CT and 77.33%±10.22% by 5-mm section CT. The mean postimplant prostate D 90 was 83.28%±10.81% by 1-mm section CT and 78.60%±15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility. (author)

  1. The association between reality-based beliefs and indirectly experienced traumatization.

    Science.gov (United States)

    Shiri, Shimon; Wexler, Isaiah D; Schwartz, Isabella; Kadari, Michal; Kreitler, Shulamith

    2010-12-01

    The purpose of the study was to examine the association between belief types and the magnitude of indirect traumatization. Specific types of beliefs were defined in terms of the cognitive orientation theory, which is a cognitive-motivational approach to the understanding, predicting, and changing of behaviors. Belief types that were analyzed included beliefs about self, general beliefs, beliefs about norms, and goal beliefs as they relate to personal growth. Study participants included 38 rescuers (body handlers), 37 nurses, and 31 rehabilitation workers who treated injured civilians that had been exposed to politically motivated violence. The Cognitive Orientation for Posttraumatic Growth Scale was used to assess beliefs about personal growth. The Revised Posttraumatic Stress Disorder Inventory was administered to evaluate indirect traumatization. The results indicate that three of the four belief types related to personal growth were associated with the level of indirect traumatization. Optimistic and positive beliefs about self and general beliefs were associated with a lower level of indirect traumatization symptomatology, suggesting that these types of beliefs may counteract indirect traumatization. On the other hand, stronger goal beliefs were associated with greater indirect traumatization. The negative association between positive goal beliefs and indirect trauma may be related to the gap the individual perceives between the hoped-for ideals and the trauma-stricken reality. These results indicate the importance of cognitive beliefs and their possible role in determining the response to indirect traumatization.

  2. Direct versus indirect detection of supersymmetric dark matter

    International Nuclear Information System (INIS)

    2003-01-01

    This document gathers the slides that were presented during the workshop 'direct versus indirect detection of supersymmetric dark matter'(about 30 contributions). This workshop intended to bring together people from the particle theory community, astrophysicists and cosmologists, as well as experimentalists involved in the detection of dark matter. The aim is to generate a discussion about current and future strategies for detection of SUSY dark matter (with focus, but not exclusively, on neutralinos). Complementarities between accelerator, direct and indirect searches as well as a comparison between the uncertainties in direct and indirect searches of dark matter, are supposed to be discussed. Among the issues which will be addressed are: -) the crucial questions related to the structure of galaxies (local dark matter density, clumping, anomalous velocity distributions, etc.) ; -) the possibilities offered by the present and future experimental facilities for direct and indirect (photon, neutrino) searches; -) the potential for the discovery of SUSY at LHC and beyond; and -) the parameterization of the SUSY breaking models beyond the minimal versions

  3. Theoretical and testing performance of an innovative indirect evaporative chiller

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yi; Xie, Xiaoyun [Department of Building Science and Technology, Tsinghua University, Beijing (China)

    2010-12-15

    An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirect evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller

  4. Hereditary haemorrhagic telangiectasia: study of hepatic vascular alterations with multi-detector row helical CT and reconstruction programs

    International Nuclear Information System (INIS)

    Memeo, Maurizio; Stabile Ianora, Amato Antonio; Scaldapane, Arnaldo; Rotondo, Antonio; Angelelli, Giuseppe; Suppressa, Patrizia; Cirulli, Anna; Sabba', Carlo

    2005-01-01

    Purpose: To evaluate hepatic alterations in patients affected by Hereditary Haemorrhagic Telangiectasia (HHT) by using multidetector row helical CT (MDCT) and new reconstruction programs. Materials and methods: An MDCT multiphasic study of the liver was performed in 105 consecutive patients: 89 considered to be affected by HHT and 16 with suspicion of disease alone. The scan delay was determined by using a test bolus of contrast material. The CT examination was performed with a triphasic technique (double arterial phase and portal venous phase). multiplanar and angiographic reconstructions were then obtained, and the images checked for the presence of shunts, hepatic perfusion disorders, vascular lesions (telangiectasis and large confluent vascular masses), indirect signs of portal hypertension, and anatomical vascular variants. Results: Hepatic vascular alterations were found in 78/105 cases (67/89) patients affected by HHT and 11/16 patients with clinical suspicion alone). Therefore HHT diagnosis was excluded in 5 patients. 78/100 (78%) patients with HHT had intrahepatic vascular alterations: arterioportal shunts in 40/78 (51.2%) arteriosystemic shunts in 16/78 (20.5%) and both shunt types in 22/78 (28.3%). Intraparenchymal perfusion disorders were found in 46/78 (58.9%) patients. Telangiectasis were recognised in 50/78 (64.1%) patients. Large confluent vascular masses (LCVMs) were identified in 20/78 (25.6%) patients. indirect signs of portal hypertension were found in 46/78 (58.9%) cases. Variant hepatic arterial anatomy was present in 38/100 cases (38%). Conclusions: Multiphasic MDCT and the new reconstruction programs enable the identification and characterisation of the complex vascular alterations typical of HHT [it

  5. Functional CT imaging: load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptionmetry (CT-OAM); Funktionelle Computertomographie: Beanspruchungsabhaengige Darstellung der subchondralen Mineralisierung mittels CT gestuetzter Osteoabsorptiometrie (CTOAM)

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U.; Schlichtenhorst, K.; Pfeifer, K.J.; Reiser, M. [Inst. fuer Klinische Radiologie, Innenstadt, Ludwig-Maximilians-Univ. Muenchen (Germany); Kersting, S.; Putz, R.; Mueller-Gerbl, M. [Anatomische Anstalt, Ludwig-Maximilians-Univ. Muenchen (Germany)

    2003-05-01

    Purpose: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM). Materials and Methods: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (triangle 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a.p. projection). Results: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p < 0.001). Conclusion: CT-OAM is a functional CT technique for visualizing and quantifying the distribution of the subchondral bone density, enabling a noninvasive load-dependent assessment of the joint surfaces. Load-dependent densitograms of hallux valgus specimens show a characteristic correlation with an increase of the HV-angle. (orig.) [German] Ziel: Darstellung und Quantifizierung der subchondralen Mineralisierung in Abhaengigkeit von unterschiedlichen Beanspruchungssituationen mittels funktioneller Computertomographie als CT-Osteoabsorptiometrie (CT-OAM). Methode: An 46 humanen Praeparaten mit Hallux valgus (HV) wurden exemplarisch die TMT I (Tarsometatarsal)- und MTP I (Metatarsophalangeal)-Gelenke des ersten Strahles (sagittal 1/1/1 mm) an einem Singleslice Spiral-CT (SCT, Somatom Plus 4, Siemens AG) untersucht. Der subchondrale Knochen wurde segmentiert, den Pixel wurde mittels Volume Rendering Technik (VRT) 10 Graustufenbereiche (D100 HU

  6. Combined MR direct thrombus imaging and non-contrast magnetic resonance venography reveal the evolution of deep vein thrombosis: a feasibility study.

    Science.gov (United States)

    Mendichovszky, I A; Priest, A N; Bowden, D J; Hunter, S; Joubert, I; Hilborne, S; Graves, M J; Baglin, T; Lomas, D J

    2017-06-01

    Lower limb deep venous thrombosis (DVT) is a common condition with high morbidity and mortality. The aim of the study was to investigate the temporal evolution of the acute thrombus by magnetic resonance imaging (MRI) and its relationship to venous recanalization in patients with recurrent DVTs. Thirteen patients with newly diagnosed lower limb DVTs underwent MRI with non-contrast MR venography (NC-MRV) and MR direct thrombus imaging (MR-DTI), an inversion-recovery water-selective fast gradient-echo acquisition. Imaging was performed within 7 days of the acute thrombotic event, then at 3 and 6 months. By 3 months from the thrombotic event a third of the thrombi had resolved and by 6 months about half of the cases had resolved on the basis of vein recanalisation using NC-MRV. On the initial MR-DTI acute thrombus was clearly depicted by hyperintense signal, while the remaining thrombi were predominantly low signal at 3 and 6 months. Some residual thrombi contained small and fragmented persisting hyperintense areas at 3 months, clearing almost completely by 6 months. Our study suggests that synergistic venous assessment with combined NC-MRV and MR-DTI is able to distinguish acute venous thrombosis from the established (old) or evolving DVT detected by ultrasound. • MRI can distinguish between acute and evolving or chronic lower limb DVT • Two advanced MRI techniques can follow the evolution of lower limb DVT • MRI could be used to avoid an incorrect diagnosis of recurrent DVT • MRI could help avoid the risks and complications of lifelong anticoagulation therapy.

  7. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  8. Comparison SPECT-CT with PET-CT in several applications of small-animal models

    International Nuclear Information System (INIS)

    Pan Yifan; Song Shaoli; Huang Gang

    2009-01-01

    With the development of medical science, monitoring dynamic biologic processes in small-animal models of diseases has become one of the most important approaches in medical studies. Important physiologic parameters that traditionally have been characterized by nuclear medicine imaging include blood flow, biochemical metabolism, and cellular receptors. Recently, nuclear medicine has been greatly facilitated by the newer development of dual-modality integrated imaging systems (SPECT-CT and PET-CT), which provide functional and anatomical images in the same scanning session, with the acquired images co-registered by means of the hardware. The purpose of this review is to compare SPECT-CT with PET-CT in several applications of small-animal models. Conclusicn: PET-CT for small animal modes in nledical research in the applications has great advantages, but SPECT-CT is still a very important role, and research low cost. (authors)

  9. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  10. System markets: Indirect network effects in action, or inaction?

    OpenAIRE

    Binken, Jeroen

    2010-01-01

    textabstractIn this dissertation, I empirically examine system markets up close. More specifically I examine indirect network effects, both demand-side and supply-side indirect network effects. Indirect network effects are the source of positive feedback in system markets, or so network effect theory tells us. Systems are composed of complementary and interdependent products, such as hardware and software. For instance, a video game system is composed of the video game console, on the one han...

  11. Indirect detection methods: Looking for what is not there

    International Nuclear Information System (INIS)

    Yeung, E.S.

    1989-01-01

    Indirect detection allows one to monitor species that normally do not give a response. It has grown from an intellectual curiosity to become an extremely useful tool. For volume displacement, polarimetry gives the best results. For charge displacement, ion chromatography and capillary zone electrophoresis are ideal situations for applying indirect fluorescence detection. LOD surpasses all but the most specialized detection schemes. Future developments in systems specially designed for indirect detection should make these schemes even more powerful

  12. Physics and basic technology of CT

    International Nuclear Information System (INIS)

    Mahesh, Mahadevappa

    2017-01-01

    Computed Tomography is one of the prime imaging modalities in any hospital around the globe. From its inception in 1973, CT technology have advanced leaps and bounds in medical diagnosis. Advances in X-ray tubes, detection technologies and image reconstruction methods led to the development of multiple-row detector CT (MDCT) technologies in early 2000, that has been the impetus for new fields such as Cardiovascular CT, Hybrid CT (PET-CT and SPECT-CT), CT Perfusion, Cone Beam CT, etc. It is now possible to image the entire organ (such as heart) in less than 0.3 seconds providing isotropic resolution images with high temporal resolution. With all X-ray imaging modalities, including CT, the concern is the radiation dose. Since CT procedures are one of the major imaging procedures performed in any hospital, it is important to optimize CT protocols in order to provide quality images at optimal radiation dose

  13. CONTRIBUTION OF INDIRECT TAXES

    Directory of Open Access Journals (Sweden)

    CHIRCULESCU MARIA FELICIA

    2015-08-01

    Full Text Available The work is based on the fact that at any time and in any society, taxation is regarded as undesirable for all taxpayers. The existence and it's manifestation is justified, because the operation of any company involves costs that must be covered by sufficient resources. Since ancient times, each state has adopted its own tax system, more or less perfected, as the state has experienced a greater or lesser economic and military power At the base of this work stays the fact that tax systems are a key factor influencing the overall efficiency of the economy. They determine the size tendency to save, invest and work, influencing the increase in production and employment, which is essential sights integral economic strategy, making tax reform an important component of economic reform. This paper aims to analyze the indirect taxes and their contribution to the public revenues in Romania, the purpose paper contains an analysis based on statistical series as indirect taxation is where tax harmonization was possible. Through analyzes, the paper aims to provide answers to the problem of the contradiction between the growing need for budgetary revenues, which entails a continuous amplification and diversification of taxation, on the one hand, and the need to stimulate economic development, on the other hand. The harmonization of indirect taxation had been achieved since this touches the free movement of goods and the freedom to supply services, not being able to say the same thing about direct taxation, which is why the European Community Treaty does not specify expressly the alignment of direct taxation, considering that direct taxation is a matter of Internal Policies that, for a country free option.

  14. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K [Department of Radiation Oncology, NYU Langone Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  15. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    International Nuclear Information System (INIS)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K

    2016-01-01

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  18. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  1. CT of the heart

    International Nuclear Information System (INIS)

    Lipton, M.J.

    1986-01-01

    Advances based upon the detector elements instead of X-ray film have greatly increased the power of X-ray imaging. Computed tomography (CT) creates cross sectional rather than projected images. Recently, high speed CT devices have been developed for cardiovascular studies. The Cine-CT scanner employs a scanning electron beam deflected on an extended tungsten target ring. Fast scans of 50 millisecond exposures at multiple levels can provide information concerning blood flow in vessels and tissues, myocardial wall motion, valve integrity, coronary bypass graft patency and proximal coronary artery anatomy. Cine-CT dynamic scanning can also provide volume imaging with small quantities (0.05 - 1.5 ml/kg) of contrast medium administered via peripheral vein injections. Cine-CT provides simultaneous measurements of cardiac dimensions and function and is rapidly becoming a new tool for quantitating myocardial blood flow, cardiac chamber volumes and wall mechanics. The future outlook is very promising for this three-dimensional cine-CT technique with high spatial resolution. High speed CT should provide unique diagnostic information and as the technology continues to improve at a rapid speed, this new imaging modality could be a challenge for angiography. (Auth.)

  2. CT-docking patient stretcher

    International Nuclear Information System (INIS)

    Mirvis, S.E.; Owens, E.; Maslyn, J.; Rizutto, M.

    1990-01-01

    This paper assesses the use of a patient stretcher that directly docks to a CT scanner for acutely injured and/or critically ill patients. The stretcher permits performance of radiography and acts as a platform for critical care monitoring and patient support devices. During a 1-year period, the prototype CT-docking stretcher was used for 35 patients sustaining acute trauma and 25 patients from critical care units. Observations were elicited from physicians, nurses and technologists concerning the advantages or disadvantages of the docking stretcher. Advantages of the CT-docking stretcher included time saved in moving patients to the CT table from the admitting/emergency ward, transfer of critically ill patients onto the stretcher in the controlled environment of the intensive care unit rather than the CT suite, increasing CT throughput by direct docking of the patient stretcher to the CT scanner rather than manual transfer of complex support and monitoring devices with the patient, decreased risk associated with physical movement of patients with potentially unstable spinal injuries or unstable physiologic status, and decrease in potential for injury to medical personnel performing patient transfer

  3. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: A phantom study

    International Nuclear Information System (INIS)

    Feng Shiting; Law, Martin Wai-Ming; Huang Bingsheng; Ng, Sherry; Li Ziping; Meng Quanfei; Khong, Pek-Lan

    2010-01-01

    Objective: To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk. Materials and methods: Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data. Results: The effective doses for head, thorax, abdomen and pelvis CT, were 0.7 mSv, 3.5 mSv, 3.0 mSv, 1.3 mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33 mGy); for thorax CT, breast (7.89 mGy); for abdomen CT, colon (6.62 mGy); for pelvis CT, bladder (4.28 mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%). Conclusion: The effective doses from these common pediatric CT examinations ranged from 0.7 mSv to 3.5 mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs.

  4. Indirect taxes on food in Southern Brazil

    Directory of Open Access Journals (Sweden)

    Denize Mirian da Silva

    2013-12-01

    Full Text Available The objective of this paper is to estimate the indirect tax burden on food for ten income classes, based on income and household total expenditure in southern Brazil. Thus it can be seen as indirect taxes on foods affect the monetary income and consumption pattern of households. To reach the objectives proposed, will be used the Pintos-Payeras (2008 model. The database iscomposed by microdata from the Household Budgeting Survey (POF 2008-2009 and the tax regulations of the country and the southern states of Brazil. The results show that indirect taxes on food in Southern Brazil is regressive when based on income and expenditure of household , ie , the poorest people pay proportionately more taxes and have their consumption pattern highest taxed ICMS (Brazilian value added tax is the tax that contributes most to the regressivity.

  5. CT arteriography of the upper abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, K; Matsuura, K; Baba, H; Numaguchi, Y; Komaki, S [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1980-04-01

    The technique of CT arteriography was introduced, and CT images of the upper abdomen were explained. Very clear enhancement of parenchyma and vessels (especially portal vein) of the object organs could be obtained by CT arteriography of the upper abdomen, anatomical structures of organs were identified more easily by CT arteriography than by conventional CT, and the amount of information obtained was increased by using CT arteriography. However, the indication of CT arteriography must be limited, because of its complexity that CT arteriography is performed after angiography and involves the invasion of patients' bodies. As described in many reports, CT arteriography is useful for malignant tumors of the liver, and it is worthwhile, especially when surgery for hepatocellular carcinoma is considered. CT arteriography for organs except the liver has not been discussed sufficiently. Therefore, an application of this method for other organs must be decided after consideration of the balance of the amount of information obtained by CT arteriography with invasion to patients.

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  7. Functional CT imaging: load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptionmetry (CT-OAM)

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Schlichtenhorst, K.; Pfeifer, K.J.; Reiser, M.; Kersting, S.; Putz, R.; Mueller-Gerbl, M.

    2003-01-01

    Purpose: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM). Materials and Methods: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (triangle 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a.p. projection). Results: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p [de

  8. CT diagnosis of the primary lung cancer and usefulness of biopsy under CT

    International Nuclear Information System (INIS)

    Fujisawa, Hidefumi; Kushihashi, Tamio

    2011-01-01

    CT especially plays an important role in imaging diagnosis of lung cancer (LC) which gives quite multiple CT findings and this paper describes details to be noted for CT findings of individual lung lesion and cancer according to 5 classes below, together with usefulness of CT-guided biopsy and positron emission tomography (PET) usage. Explained are as follows: Important points in histopathology and CT findings from adenomatous hyperplasia (AH) to atypical AH (pre-invasive lesion); Differential CT diagnosis of benignity or malignancy of pulmonary nodes and tumors; Typical CT findings of LC of peripheral type of invasive or exclusive proliferative type, and pulmonary hillar type; Atypical CT findings of LC/having atypical inner structure such as presenting atypical calcification and atypical cavity/having atypical morphology such as presenting pneumonia-like finding, exhibiting regular or linear edge, and existing at atypical region like extrapleural lumen /having atypical progression rate such as showing rapid or slow doubling time of the volume and shrinking tentatively during the progress/of juvenile LC/and generated from background lung diseases such as interstitial pneumonia, tuberculosis, pneumoconiosis like asbestosis, pneumosilicosis, and pulmonary emphysema and bulla; and Regional ground glass opacity. As well, authors mention about the usefulness of CT-guided needle biopsy of the pulmonary lesion which enables to take the nodal specimen as small as <10 mm. Most frequent complication of the biopsy is pneumothorax (10-50%). How to use PET for LC examination is also commented with its usability and limitation. (T.T.)

  9. CT of thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Sone, S.; Higashihara, T.; Morimoto, S.; Ikezoe, J.; Arisawa, J. (Osaka Univ. (Japan). Faculty of Medicine)

    1982-08-01

    Based on 17 patients with thymoma (8 with myasthenia gravis and 9 free from it); 1. The effectiveness of CT, conventional radiography and pneumomediastinography in the detection of thymomas was determined and the results compared. 2. The CT findings of thymomas were discussed and the CT features which seemed to suggest malignant thymomas were evaluated. The results were as follows: 1. Of the 17 cass with thymomas, 13 were diagnosed from p-a films, 13 from lateral films, and 16 from CT. Of the 16 thymomas, 14 were diagnosed from lateral tomography. Mass densities were shown in all 15 cases in which pneumomediastinography were performed. 2. Benign thymomas showed round or oval smoothly marginated mass. The fatty plane between the mass and the mediastinal structures was nicely preserved. 3. Malignant thymoma frequently showed a plaque-like mass with more or less irregular or lobulated contours with obliteration of the fatty planes of the cardiovascular structures. Tumor calcification was shown in 4 of 10 malignant thymomas. 4. Slight tumor invasion to the mediastinal pleura and lung was difficult to predict from the CT images.

  10. Fibrosing mediastinitis and thrombosis of superior vena cava associated with Behcet's disease

    International Nuclear Information System (INIS)

    Harman, Mustafa; Sayarlioglu, Mehmet; Arslan, Halil; Ayakta, Hayati; Harman, Ece

    2003-01-01

    We present CT, MRI and venography findings in 13-year boy with mediastinal fibrosis and superior vena cava (SVC) thrombosis associated with Behcet's disease. Fibrosing mediastinitis is an excessive fibrotic reaction that occurs in the mediastinum and may lead to compression of mediastinal structures (especially vascular). This condition is usually idiopathic, though many (and perhaps most) cases in the USA are thought to be caused by an abnormal immunologic response to Histoplasma capsulatum infection. SVC syndrome secondary to extrinsic compression by mediastinal fibrosis combined with Behcet's disease has rarely been described. Radiological investigations of this syndrome are necessary to avoid a useless anticoagulant therapy

  11. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  12. Indirect Estimation of Selected Measures of Fertility and Marital ...

    African Journals Online (AJOL)

    DLHS6

    2018-01-09

    Jan 9, 2018 ... marital status distribution data of India especially of the 2011 census in deriving indirectly the fertility measures .... 2011 Census, Economic and Political weekly, EPW Vol. ... Indirect Estimates of Total Fertility Rate Using Child.

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  15. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  16. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  17. Brain tumor and CT, 1

    International Nuclear Information System (INIS)

    Suzuki, Nobuyuki; Katada, Kazuhiro; Shinomiya, Youichi; Sano, Hirotoshi; Kanno, Tetsuo

    1981-01-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information which is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively 27 cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor. (author)

  18. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  19. Direct versus indirect detection of supersymmetric dark matter

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    This document gathers the slides that were presented during the workshop 'direct versus indirect detection of supersymmetric dark matter'(about 30 contributions). This workshop intended to bring together people from the particle theory community, astrophysicists and cosmologists, as well as experimentalists involved in the detection of dark matter. The aim is to generate a discussion about current and future strategies for detection of SUSY dark matter (with focus, but not exclusively, on neutralinos). Complementarities between accelerator, direct and indirect searches as well as a comparison between the uncertainties in direct and indirect searches of dark matter, are supposed to be discussed. Among the issues which will be addressed are: -) the crucial questions related to the structure of galaxies (local dark matter density, clumping, anomalous velocity distributions, etc.) ; -) the possibilities offered by the present and future experimental facilities for direct and indirect (photon, neutrino) searches; -) the potential for the discovery of SUSY at LHC and beyond; and -) the parameterization of the SUSY breaking models beyond the minimal versions.

  20. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    Science.gov (United States)

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  1. Molecular imaging with {sup 68}Ga-SSTR PET/CT and correlation to immunohistochemistry of somatostatin receptors in neuroendocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Kaemmerer, Daniel; Haugvik, Sven-Petter; Hommann, Merten [Zentralklinik Bad Berka GmbH, Department of General and Visceral Surgery, Bad Berka (Germany); Peter, Luisa; Lupp, Amelie; Schulz, Stefan [University of Jena, Department of Pharmacology and Toxicology, Jena (Germany); Saenger, Joerg [Laboratory of Pathology and Cytology, Bad Berka (Germany); Prasad, Vikas; Kulkarni, Harshad; Baum, Richard Paul [Zentralklinik Bad Berka, Department of Nuclear Medicine and Center for PET, Bad Berka (Germany)

    2011-09-15

    Somatostatin receptors (SSTR) are known for an overexpression in gastroenteropancreatic neuroendocrine tumours (GEP-NET). The aim of the present study was to find out if the receptor density predicted by the semi-quantitative parameters generated from the static positron emission tomography (PET/CT) correlated with the in vitro immunohistochemistry using a novel rabbit monoclonal anti-SSTR2A antibody (clone UMB-1) for specific SSTR2A immunohistochemistry and polyclonal antibodies for SSTR1 and 3-5. Overall 14 surgical specimens generated from 34 histologically documented GEP-NET patients were correlated with the preoperative {sup 68}Ga-DOTA-NOC PET/CT. Quantitative assessment of the receptor density was done using the immunoreactive score (IRS) of Remmele and Stegner; the additional 4-point IRS classification for immunohistochemistry and standardized uptake values (SUV{sub max} and SUV{sub mean}) were used for PET/CT. The IRS for SSTR2A and SSTR5 correlated highly significant with the SUV{sub max} on the PET/CT (p < 0.001; p < 0.05) and the IRS for SSTR2A with the SUV{sub mean} (p < 0.013). The level of SSTR2A score correlated significantly with chromogranin A staining and indirectly to the tumour grading. The highly significant correlation between SSTR2A and SSTR5 and the SUV{sub max} on the {sup 68}Ga-DOTA-NOC PET/CT scans is concordant with the affinity profile of {sup 68}Ga-DOTA-NOC to the SSTR subtypes and demonstrates the excellent qualification of somatostatin analogues in the diagnostics of NET. This study correlating somatostatin receptor imaging using {sup 68}Ga-DOTA-NOC PET/CT with immunohistochemically analysed SSTR also underlines the approval of therapy using somatostatin analogues, follow-up imaging as well as radionuclide therapy. (orig.)

  2. Estimating direct and indirect costs of premenstrual syndrome.

    Science.gov (United States)

    Borenstein, Jeff; Chiou, Chiun-Fang; Dean, Bonnie; Wong, John; Wade, Sally

    2005-01-01

    To quantify the economic impact of premenstrual syndrome (PMS) on the employer. Data were collected from 374 women aged 18-45 with regular menses. Direct costs were quantified using administrative claims of these patients and the Medicare Fee Schedule. Indirect costs were quantified by both self-reported days of work missed and lost productivity at work. Regression analyses were used to develop a model to project PMS-related direct and indirect costs. A total of 29.6% (n = 111) of the participants were diagnosed with PMS. A PMS diagnosis was associated with an average annual increase of $59 in direct costs (P increase in direct medical costs and a large increase in indirect costs.

  3. PET/CT and radiotherapy

    International Nuclear Information System (INIS)

    Messa, C.; CNR, Milano; S. Gerardo Hospital, Monza; Di Muzio, N.; Picchio, M.; Bettinardi, V.; Gilardi, M.C.; CNR, Milano; San Raffaele Scientific Institute, Milano; Fazio, F.; CNR, Milano; San Raffaele Scientific Institute, Milano; San Raffaele Scientific Institute, Milano

    2006-01-01

    This article reviews the state of the art of PET/CT applications in radiotherapy, specifically its use in disease staging, patient selection, treatment planning and treatment evaluation. Diseases for which radiotherapy with radical intent is indicated will be considered, as well as those in which PET/CT may actually change the course of disease. The methodological and technological aspects of PET/CT in radiotherapy are discussed, focusing on the problem of target volume definition with CT and PET functional imaging and the problem of tumor motion with respect to imaging and dose delivery

  4. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  5. Direct spondylolisthesis identification and measurement in MR/CT using detectors trained by articulated parameterized spine model

    Science.gov (United States)

    Cai, Yunliang; Leung, Stephanie; Warrington, James; Pandey, Sachin; Shmuilovich, Olga; Li, Shuo

    2017-02-01

    The identification of spondylolysis and spondylolisthesis is important in spinal diagnosis, rehabilitation, and surgery planning. Accurate and automatic detection of spinal portion with spondylolisthesis problem will significantly reduce the manual work of physician and provide a more robust evaluation for the spine condition. Most existing automatic identification methods adopted the indirect approach which used vertebrae locations to measure the spondylolisthesis. However, these methods relied heavily on automatic vertebra detection which often suffered from the pool spatial accuracy and the lack of validated pathological training samples. In this study, we present a novel spondylolisthesis detection method which can directly locate the irregular spine portion and output the corresponding grading. The detection is done by a set of learning-based detectors which are discriminatively trained by synthesized spondylolisthesis image samples. To provide sufficient pathological training samples, we used a parameterized spine model to synthesize different types of spondylolysis images from real MR/CT scans. The parameterized model can automatically locate the vertebrae in spine images and estimate their pose orientations, and can inversely alter the vertebrae locations and poses by changing the corresponding parameters. Various training samples can then be generated from only a few spine MR/CT images. The preliminary results suggest great potential for the fast and efficient spondylolisthesis identification and measurement in both MR and CT spine images.

  6. Indirect methods for reference interval determination - review and recommendations.

    Science.gov (United States)

    Jones, Graham R D; Haeckel, Rainer; Loh, Tze Ping; Sikaris, Ken; Streichert, Thomas; Katayev, Alex; Barth, Julian H; Ozarda, Yesim

    2018-04-19

    Reference intervals are a vital part of the information supplied by clinical laboratories to support interpretation of numerical pathology results such as are produced in clinical chemistry and hematology laboratories. The traditional method for establishing reference intervals, known as the direct approach, is based on collecting samples from members of a preselected reference population, making the measurements and then determining the intervals. An alternative approach is to perform analysis of results generated as part of routine pathology testing and using appropriate statistical techniques to determine reference intervals. This is known as the indirect approach. This paper from a working group of the International Federation of Clinical Chemistry (IFCC) Committee on Reference Intervals and Decision Limits (C-RIDL) aims to summarize current thinking on indirect approaches to reference intervals. The indirect approach has some major potential advantages compared with direct methods. The processes are faster, cheaper and do not involve patient inconvenience, discomfort or the risks associated with generating new patient health information. Indirect methods also use the same preanalytical and analytical techniques used for patient management and can provide very large numbers for assessment. Limitations to the indirect methods include possible effects of diseased subpopulations on the derived interval. The IFCC C-RIDL aims to encourage the use of indirect methods to establish and verify reference intervals, to promote publication of such intervals with clear explanation of the process used and also to support the development of improved statistical techniques for these studies.

  7. Adenocarcinoma Prostate With Neuroendocrine Differentiation: Potential Utility of 18F-FDG PET/CT and 68Ga-DOTANOC PET/CT Over 68Ga-PSMA PET/CT.

    Science.gov (United States)

    Parida, Girish Kumar; Tripathy, Sarthak; Datta Gupta, Shreya; Singhal, Abhinav; Kumar, Rakesh; Bal, Chandrasekhar; Shamim, Shamim Ahmed

    2018-04-01

    Ga-PSMA PET/CT is the upcoming imaging modality for staging, restaging and response assessment of prostate cancer. However, due to neuroendocrine differentiation in some of patients with prostate cancer, they express somatostatin receptors instead of prostate specific membrane antigen. This can be exploited and other modalities like Ga-DOTANOC PET/CT and F-FDG PET/CT should be used in such cases for guiding management. We hereby discuss a similar case of 67-year-old man of adenocarcinoma prostate with neuroendocrine differentiation, which shows the potential pitfall of Ga-PSMA PET/CT imaging and benefit of Ga-DOTANOC PET/CT and F-FDG PET/CT in such cases.

  8. NMR-CT scanner

    International Nuclear Information System (INIS)

    Kose, Katsumi; Sato, Kozo; Sugimoto, Hiroshi; Sato, Masataka.

    1983-01-01

    A brief explanation is made on the imaging methods for a practical diagnostic NMR-CT scanner : A whole-body NMR-CT scanner utilizing a resistive magnet has been developed by Toshiba in cooperation with the Institute for Solid State Physics, the University of Tokyo. Typical NMR-CT images of volunteers and patients obtained in the clinical experiments using this device are presented. Detailed specifications are also shown about the practical NMR-CTs which are to be put on the market after obtaining the government approval. (author)

  9. CT and HR-CT of exogenous allergic alveolitis

    International Nuclear Information System (INIS)

    Lederer, A.; Kullnig, P.; Pongratz, M.

    1992-01-01

    The CT changes on conventional and high resolution CT in 14 patients with exogeneous allergic alveolitis (EAA) were analysed retrospectively. There were 8 patients with clinically subacute disease, 5 patients in a chronic stage and 1 patient with acute EAA. The appearances and their distribution were examined. Seven of the 8 patients in the subacute stage showed a ground glass pattern and multiple nodules of less than 2 mm. All patients in the chronic stage showed a combination of fine infiltrates, small nodules and irregular linear densities; distortion of the pulmonary pattern was present in 3 cases. The patient with acute EAA showed diffuse dense areas of consolidation in both lungs as well as multiple nodules and a ground glass pattern. The CT appearances of EAA correspond with the basic micropathology and, within the clinical context, permit diagnostic classification. (orig.) [de

  10. Circumventing resistance: using values to indirectly change attitudes.

    Science.gov (United States)

    Blankenship, Kevin L; Wegener, Duane T; Murray, Renee A

    2012-10-01

    Most research on persuasion examines messages that directly address the attitude of interest. However, especially when message recipients are inclined to resist change, indirect methods might be more effective. Because values are rarely attacked and defended, value change could serve as a useful indirect route for attitude change. Attitudes toward affirmative action changed more when the value of equality was attacked (indirect change) than when affirmative action was directly attacked using the same message (Experiments 1-2). Changes in confidence in the value were responsible for the indirect change when the value was attacked (controlling for changes in favorability toward the value), whereas direct counterarguments to the message were responsible for the relative lack of change when the attitude was attacked directly (Experiment 2). Attacking the value of equality influenced attitudes toward policies related to the value but left policy attitudes unrelated to the value unchanged (Experiment 3). Finally, a manipulation of value confidence that left attitudes toward the value intact demonstrated similar confidence-based influences on policies related to the value of freedom (Experiment 4). Undermined value confidence also resulted in less confidence in the resulting policy attitudes controlling for the changes in the policy attitudes themselves (Experiments 3 and 4). Therefore, indirect change through value attacks presented a double threat--to both the policy attitudes and the confidence with which those policy attitudes were held (potentially leaving them open to additional influence).

  11. Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutt, Antoine; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [CHRU et Universite de Lille, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Duhamel, Alain; Deken, Valerie [CHRU et Universite de Lille, Department of Biostatistics (EA 2694), Lille (France); Molinari, Francesco [Centre Hospitalier General de Tourcoing, Department of Radiology, Tourcoing (France)

    2016-06-15

    To investigate the reliability of ungated, high-pitch dual-source CT for coronary artery calcium (CAC) screening. One hundred and eighty-five smokers underwent a dual-source CT examination with acquisition of two sets of images during the same session: (a) ungated, high-pitch and high-temporal resolution acquisition over the entire thorax (i.e., chest CT); (b) prospectively ECG-triggered acquisition over the cardiac cavities (i.e., cardiac CT). Sensitivity and specificity of chest CT for detecting positive CAC scores were 96.4 % and 100 %, respectively. There was excellent inter-technique agreement for determining the quantitative CAC score (ICC = 0.986). The mean difference between the two techniques was 11.27, representing 1.81 % of the average of the two techniques. The inter-technique agreement for categorizing patients into the four ranks of severity was excellent (weighted kappa = 0.95; 95 % CI 0.93-0.98). The inter-technique differences for quantitative CAC scores did not correlate with BMI (r = 0.05, p = 0.575) or heart rate (r = -0.06, p = 0.95); 87.2 % of them were explained by differences at the level of the right coronary artery (RCA: 0.8718; LAD: 0.1008; LCx: 0.0139; LM: 0.0136). Ungated, high-pitch dual-source CT is a reliable imaging mode for CAC screening in the conditions of routine chest CT examinations. (orig.)

  12. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  13. Comparison of the 68Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT in the Evaluation of Suspected Primary Pheochromocytomas and Paragangliomas.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Wang, Ling; Wang, Zhenghua; Li, Wei; Huo, Li; Zhang, Jingjing

    2017-07-01

    Anatomical imaging modalities including CT and MRI are the mainstay of evaluation of primary pheochromocytoma or paraganglioma. However, nuclear medicine imaging is frequently necessary to determine the nature of the lesions. The purpose of this investigation is to assess which commonly used nuclear medicine modality might have a better diagnostic value in this clinical setting. Eight patients who had been suspected of having either primary pheochromocytoma or primary paraganglioma and 1 patient with known pheochromocytoma were included in the analysis. Among the 8 patients without known diagnosis, 7 had been suggested by anatomical imaging modalities, whereas one of them presented with initial negative anatomical imaging interpretation. All of 9 patients underwent Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT for further evaluation. The imaging findings were compared with postsurgical pathology and follow-up. Both Ga-DOTATATA PET/CT and MIBG SPECT/CT accurately identified 9 primary tumors, whereas FDG PET/CT showed increased activity in 8 of 9 primary tumors. Both Ga-DOTATATA and FDG PET/CT are able to detect associated extra-adrenal lesions not shown on MIBG study in patients with multiple endocrine neoplasia syndrome. Ga-DOTATATA PET/CT could be the nuclear medicine imaging choice to evaluate suspected primary pheochromocytoma or paraganglioma, especially in the situation of multiple endocrine neoplasia syndrome.

  14. Global indirect aerosol effects: a review

    Directory of Open Access Journals (Sweden)

    U. Lohmann

    2005-01-01

    Full Text Available Aerosols affect the climate system by changing cloud characteristics in many ways. They act as cloud condensation and ice nuclei, they may inhibit freezing and they could have an influence on the hydrological cycle. While the cloud albedo enhancement (Twomey effect of warm clouds received most attention so far and traditionally is the only indirect aerosol forcing considered in transient climate simulations, here we discuss the multitude of effects. Different approaches how the climatic implications of these aerosol effects can be estimated globally as well as improvements that are needed in global climate models in order to better represent indirect aerosol effects are discussed in this paper.

  15. Indirect methods for wake potential integration

    International Nuclear Information System (INIS)

    Zagorodnov, I.

    2006-05-01

    The development of the modern accelerator and free-electron laser projects requires to consider wake fields of very short bunches in arbitrary three dimensional structures. To obtain the wake numerically by direct integration is difficult, since it takes a long time for the scattered fields to catch up to the bunch. On the other hand no general algorithm for indirect wake field integration is available in the literature so far. In this paper we review the know indirect methods to compute wake potentials in rotationally symmetric and cavity-like three dimensional structures. For arbitrary three dimensional geometries we introduce several new techniques and test them numerically. (Orig.)

  16. CT findings of infant epilepsy

    International Nuclear Information System (INIS)

    Hojoh, Hiroatsu; Kataoka, Kenkichi; Nakagawa, Yoshihiro; Nakano, Shozo; Tomita, Yutaka.

    1982-01-01

    CT diagnosis of infantile epilepsy was evaluated. High incidence of abnormal CT findings in infantile spasms and Lennox-Gastaut syndrome was same as in other reports. Comparison between CT findings and neurological complications and that between CT findings and electroencephalogram findings revealed a stronger relationship existing in the former. This suggested that CT is more useful as a measure to detect underlying diseases which are due to organic change of the brain to cause epilepsy, rather than as that to disclose epileptic primary lesions of functional change. (Ueda, J.)

  17. CT of thymoma

    International Nuclear Information System (INIS)

    Sone, Shusuke; Higashihara, Tokuro; Morimoto, Shizuo; Ikezoe, Junpei; Arisawa, Jun

    1982-01-01

    Based on 17 patients with thymoma (8 with myasthenia gravis and 9 free from it); 1. The effectiveness of CT, conventional radiography and pneumomediastinography in the detection of thymomas was determined and the results compared. 2. The CT findings of thymomas were discussed and the CT features which seemed to suggest malignant thymomas were evaluated. The results were as follows: 1. Of the 17 cases with thymomas, 13 were diagnosed from p-a films, 13 from lateral films, and 16 from CT. Of the 16 thymomas, 14 were diagnosed from lateral tomography. Mass densities were shown in all 15 cases in which pneumomediastinography were performed. 2. Benign thymomas showed round or oval smoothly marginated mass. The fatty plane between the mass and the mediastinal structures was nicely preserved. 3. Malignant thymoma frequently showed a plaque-like mass with more or less irregular or lobulated contoures with obliteration of the fatty planes of the cardiovascular structures. Tumor calcification was shown in 4 of 10 malignant thymomas. 4. Slight tumor invasion to the mediastinal pleura and lung was difficult to predict from the CT images. (author)

  18. F-FDG PET/CT (PET/CT) influences management in patients with known or suspected pancreatic cancer

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Kalff, Victor; Cherk, Martin H.; Yap, Kenneth SK.; Evans, Peter; Kelly, Michael J.

    2009-01-01

    Full text: Objective: To assess the impact on clinical management of PET/CT in patients with known or suspected pancreatic cancer. Methods: Between April 2006 and September 2008,25 PET/CT scans were performed using a dedicated PET/CT (22 scans) or a coincidence hybrid PET/CT camera (3 scans) in 23 patients with known or suspected pancreatic cancer. 17 scans were performed for initial evaluation and 8 for restaging of disease. The pre-PET/CT management plan and for intent were prospectively recorded in all cases. The post-PET/CT management plan was determined from the medical record and for discussions with treating clinicians. The impact of PET/CT on management was classified as High, Medium, Low or None, defined using ANZAPNM PET data collection project criteria. Follow-up was used to reconcile any discordance between PET/CT and conventional imaging. Results: Overall, PET/CT management impact was classified as high (n equal 7), medium (n equal 4), low (n equal 10) or none (n equal 4). Impact was either high or medium in l l/25 patients (44%) (95% confidence interval; 24 - 64%). Impact was high in 4/17 patients imaged for initial evaluation, predominantly by clarifying equivocal lesions on conventional imaging. In restaged patients, PET/CT impact was high in 3/8, and it correctly modified disease extent in 5/8. In the 16 discordant studies, PET/CT assessment was correct in 10, conventional imaging in 4 and there was insufficient information in 2. Conclusion: PET/CT has high or medium management impact in 44% of patients imaged for known or suspected pancreatic cancer, more commonly during restaging. Discordant PET/CT results were usually correct.

  19. SedCT: MATLAB™ tools for standardized and quantitative processing of sediment core computed tomography (CT) data collected using a medical CT scanner

    Science.gov (United States)

    Reilly, B. T.; Stoner, J. S.; Wiest, J.

    2017-08-01

    Computed tomography (CT) of sediment cores allows for high-resolution images, three-dimensional volumes, and down core profiles. These quantitative data are generated through the attenuation of X-rays, which are sensitive to sediment density and atomic number, and are stored in pixels as relative gray scale values or Hounsfield units (HU). We present a suite of MATLAB™ tools specifically designed for routine sediment core analysis as a means to standardize and better quantify the products of CT data collected on medical CT scanners. SedCT uses a graphical interface to process Digital Imaging and Communications in Medicine (DICOM) files, stitch overlapping scanned intervals, and create down core HU profiles in a manner robust to normal coring imperfections. Utilizing a random sampling technique, SedCT reduces data size and allows for quick processing on typical laptop computers. SedCTimage uses a graphical interface to create quality tiff files of CT slices that are scaled to a user-defined HU range, preserving the quantitative nature of CT images and easily allowing for comparison between sediment cores with different HU means and variance. These tools are presented along with examples from lacustrine and marine sediment cores to highlight the robustness and quantitative nature of this method.

  20. CT in normal pressure hydrocephalus. Correlation between CT and clinical response to shunting

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, K.; Nogaki, H.; Noda, M.; Kusunoki, T.; Tamaki, N. (Kobe Univ. (Japan). School of Medicine)

    1981-02-01

    CT scans were obtained on 33 patients (age 73y. to 31y.) with the diagnosis of normal pressure hydrocephalus. In each case, the diagnosis was made on the basis of the symptoms, CT and cisternographic findings. Underlying diseases of normal pressure hydrocephalus are ruptured aneurysms (21 cases), arteriovenous malformations (2 cases), head trauma (1 case), cerebrovascular accidents (1 case) and idiopathie (8 cases). Sixteen of 33 patients showed marked improvement, five, moderate or minimal improvement, and twelve, no change. The results were compared with CT findings and clinical response to shunting. CT findings were classified into five types, bases on the degree of periventricular hypodensity (P.V.H.), the extent of brain damage by underlying diseases, and the degree of cortical atrophy. In 17 cases of type (I), CT shows the presence of P.V.H. with or without minimal frontal lobe damage and no cortical atrophy. The good surgical improvements were achieved in all cases of type (I) by shunting. In 4 cases of type (II), CT shows the presence of P.V.H. and severe brain damage without cortical atrophy. The fair clinical improvements were achieved in 2 cases (50%) by shunting. In one case of type (III), CT shows the absence of P.V.H. without brain damage nor cortical atrophy. No clinical improvement was obtained by shunting in this type. In 9 cases of type (IV) with mild cortical atrophy, the fair clinical improvement was achieved in two cases (22%) and no improvement in 7 cases. In 2 cases of type (V) with moderate or marked cortical atrophy, no clinical improvement was obtained by shunting. In conclusion, it appeared from the present study that there was a good correlation between the result of shunting and the type of CT, and clinical response to shunting operation might be predicted by classification of CT findings.

  1. Estimation of skull table thickness with clinical CT and validation with microCT.

    Science.gov (United States)

    Lillie, Elizabeth M; Urban, Jillian E; Weaver, Ashley A; Powers, Alexander K; Stitzel, Joel D

    2015-01-01

    Brain injuries resulting from motor vehicle crashes (MVC) are extremely common yet the details of the mechanism of injury remain to be well characterized. Skull deformation is believed to be a contributing factor to some types of traumatic brain injury (TBI). Understanding biomechanical contributors to skull deformation would provide further insight into the mechanism of head injury resulting from blunt trauma. In particular, skull thickness is thought be a very important factor governing deformation of the skull and its propensity for fracture. Current computed tomography (CT) technology is limited in its ability to accurately measure cortical thickness using standard techniques. A method to evaluate cortical thickness using cortical density measured from CT data has been developed previously. This effort validates this technique for measurement of skull table thickness in clinical head CT scans using two postmortem human specimens. Bone samples were harvested from the skulls of two cadavers and scanned with microCT to evaluate the accuracy of the estimated cortical thickness measured from clinical CT. Clinical scans were collected at 0.488 and 0.625 mm in plane resolution with 0.625 mm thickness. The overall cortical thickness error was determined to be 0.078 ± 0.58 mm for cortical samples thinner than 4 mm. It was determined that 91.3% of these differences fell within the scanner resolution. Color maps of clinical CT thickness estimations are comparable to color maps of microCT thickness measurements, indicating good quantitative agreement. These data confirm that the cortical density algorithm successfully estimates skull table thickness from clinical CT scans. The application of this technique to clinical CT scans enables evaluation of cortical thickness in population-based studies. © 2014 Anatomical Society.

  2. CT-based virtual tracheobronchoscopy in children - comparison with axial CT and multiplanar reconstruction: preliminary results

    International Nuclear Information System (INIS)

    Sorantin, Erich; Lindbichler, Franz; Eber, Ernst; Schimpl, Guenther

    2002-01-01

    Background: 3D post-processing of spiral-CT (S-CT) data using perspective projection allows the generation of virtual views similar to endoscopy. Objective: To evaluate whether simultaneous reading of axial S-CT, multiplanar reconstruction (MPR) and virtual tracheobronchoscopy (VTB) is more precise and accurate than reading of axial S-CT and MPR alone in paediatric patients. Materials and methods: S-CT studies of 15 symptomatic and 4 normal patients were investigated. Two radiologists independently read two sets of images for airway abnormalities: first axial CT and MPR, followed by axial CT, MPR and VTB. A final decision was later made by consensus. All results were compared to fibre-optic bronchoscopy (FTB). Interobserver agreement was used as an indicator of precision for the display technique used. Results: At reading of axial S-CT and MPR an interobserver agreement of 89.5% (κ=0.776, P<0.00103) was found. Based on the consensus decision, a diagnostic accuracy of 89.5% at a sensitivity 86.6% and specificity of 100% (κ=0.776, 95% CI 0.491-1.062, P<0.00103) was achieved. At reporting on axial S-CT, MPR and VTB, all cases were classified correctly by both readers, indicating 100% accuracy, interobserver agreement, sensitivity and specificity (κ=1.00, 95% CI 1.0-1.0, P<0.000258). Conclusions: The simultaneous display of axial S-CT, MPR and VTB raises the precision, accuracy and sensitivity of radiological reports. (orig.)

  3. Indirect Catastrophic Injuries in Olympic Styles of Wrestling in Iran

    OpenAIRE

    Kordi, Ramin; Ziaee, Vahid; Rostami, Mohsen; Wallace, W. Angus

    2011-01-01

    Background: Data on indirect catastrophic injuries in wrestling are scarce. Objectives: To develop a profile of indirect catastrophic injuries in international styles of wrestling and to describe possible risk factors. Study Design: Retrospective case series; Level of evidence, 3. Methods: Indirect catastrophic injuries that occurred in wrestling clubs in Iran from July 1998 to June 2005 were identified by contacting several sources. The cases were retrospectively reviewed. Results: The injur...

  4. CT of splenic trauma

    International Nuclear Information System (INIS)

    Griffiths, B.G.; Federle, M.P.; Minagi, H.; Jeffrey, R.B.

    1986-01-01

    Fifty-five consecutive cases of surgically proved splenic injuries were evaluated by CT. CT correctly identified 54 splenic injuries, with one false-negative and three false-positive studies. In the single false-negative study and in two of the three false-positive studies, CT correctly indicated the presence of a large hemoperitoneum and other abdominal visceral lacerations and so correctly indicated the need for surgery. Of the 55 proved cases of splenic injury, CT revealed hemoperitoneum in 54 (99%), perisplenic clot in 47 (85%), splenic laceration in 39 (71%), and subcapsular hematoma in 13 (24%). Perisplenic clot can be distinguished from lysed blood in the peritoneal cavity and is a sensitive and specific sign of splenic trauma, even in the absence of visible splenic laceration. The authors conclude that CT is highly reliable means of evaluating splenic trauma

  5. Inconsistency between direct and indirect comparisons of competing interventions: meta-epidemiological study.

    Science.gov (United States)

    Song, Fujian; Xiong, Tengbin; Parekh-Bhurke, Sheetal; Loke, Yoon K; Sutton, Alex J; Eastwood, Alison J; Holland, Richard; Chen, Yen-Fu; Glenny, Anne-Marie; Deeks, Jonathan J; Altman, Doug G

    2011-08-16

    To investigate the agreement between direct and indirect comparisons of competing healthcare interventions. Meta-epidemiological study based on sample of meta-analyses of randomised controlled trials. Data sources Cochrane Database of Systematic Reviews and PubMed. Inclusion criteria Systematic reviews that provided sufficient data for both direct comparison and independent indirect comparisons of two interventions on the basis of a common comparator and in which the odds ratio could be used as the outcome statistic. Inconsistency measured by the difference in the log odds ratio between the direct and indirect methods. The study included 112 independent trial networks (including 1552 trials with 478,775 patients in total) that allowed both direct and indirect comparison of two interventions. Indirect comparison had already been explicitly done in only 13 of the 85 Cochrane reviews included. The inconsistency between the direct and indirect comparison was statistically significant in 16 cases (14%, 95% confidence interval 9% to 22%). The statistically significant inconsistency was associated with fewer trials, subjectively assessed outcomes, and statistically significant effects of treatment in either direct or indirect comparisons. Owing to considerable inconsistency, many (14/39) of the statistically significant effects by direct comparison became non-significant when the direct and indirect estimates were combined. Significant inconsistency between direct and indirect comparisons may be more prevalent than previously observed. Direct and indirect estimates should be combined in mixed treatment comparisons only after adequate assessment of the consistency of the evidence.

  6. Evaluation of pre and post-operative spinal plain CT and CT-myelography

    International Nuclear Information System (INIS)

    Nagase, Joji; Inoue, Shunichi; Miyasaka, Hitoshi; Kamata, Sakae; Shinohara, Hiroyasu.

    1983-01-01

    Confirmation of the level of scan slices is essential for the CT diagnosis of spinal and spinal-cord diseases. Pre- and postoperative comparison should be made on the same level. For reading of plain CT and CTM, window levels should be identical pre- and postoperatively. Both methods demonstrated the spinal canal, morphology of the spinal cord, and three-Fdimensional pathologic pictures inside and outside the spinal cord. Preoperative CT contributed useful information on the pathologic conditions and selection of surgical procedures and routes. Postoperative plain CT confirmed surgical results, and CTM revealed the spinal cord and the subarachnoid space, as well as the range and degree of decompression from the spinal cord. (Chiba, N.)

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow new CT scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ...

  8. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  9. Variation in quantitative CT air trapping in heavy smokers on repeat CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Mets, Onno M.; Gietema, Hester A.; Jong, Pim A. de [University Medical Center Utrecht, Radiology, Heidelberglaan 100, Postbus 85500, Utrecht (Netherlands); Isgum, Ivana; Mol, Christian P. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Zanen, Pieter [University Medical Center Utrecht, Pulmonology, Utrecht (Netherlands); Prokop, Mathias [Radboud University Nijmegen Medical Centre, Radiology, Nijmegen (Netherlands); University Medical Center Utrecht, Radiology, Heidelberglaan 100, Postbus 85500, Utrecht (Netherlands)

    2012-12-15

    To determine the variation in quantitative computed tomography (CT) measures of air trapping in low-dose chest CTs of heavy smokers. We analysed 45 subjects from a lung cancer screening trial, examined by CT twice within 3 months. Inspiratory and expiratory low-dose CT was obtained using breath hold instructions. CT air trapping was defined as the percentage of voxels in expiratory CT with an attenuation below -856 HU (EXP{sub -856}) and the expiratory to inspiratory ratio of mean lung density (E/I-ratio{sub MLD}). Variation was determined using limits of agreement, defined as 1.96 times the standard deviation of the mean difference. The effect of both lung volume correction and breath hold reproducibility was determined. The limits of agreement for uncorrected CT air trapping measurements were -15.0 to 11.7 % (EXP{sub -856}) and -9.8 to 8.0 % (E/I-ratio{sub MLD}). Good breath hold reproducibility significantly narrowed the limits for EXP{sub -856} (-10.7 to 7.5 %, P = 0.002), but not for E/I-ratio{sub MLD} (-9.2 to 7.9 %, P = 0.75). Statistical lung volume correction did not improve the limits for EXP{sub -856} (-12.5 to 8.8 %, P = 0.12) and E/I-ratio{sub MLD} (-7.5 to 5.8 %, P = 0.17). Quantitative air trapping measures on low-dose CT of heavy smokers show considerable variation on repeat CT examinations, regardless of lung volume correction or reproducible breath holds. (orig.)

  10. Clinical values of CT and dynamic CT in brain infarction

    International Nuclear Information System (INIS)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul

    1985-01-01

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre-and postcontrast CT

  11. Clinical values of CT and dynamic CT in brain infarction

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University College of Medicine, Jeonju (Korea, Republic of)

    1985-04-15

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre

  12. Social Dilemmas and Indirect Reciprocity: A systematic review

    Directory of Open Access Journals (Sweden)

    Cristian Acosta

    2014-08-01

    Full Text Available Indirect reciprocity is an evolutionary theory of altruism and cooperation in social dilemmas. Its explanation of cooperation incorporates information on the reputation people hold of other people regarding whether they are cooperative or not. This study systematically reviewed the current empirical literature on indirect reciprocity in social dilemma situations. The following databases were consulted: ScienceDirect, EBSCO, and OVID, using has key words "indirect reciprocity" AND "dilemma" OR "cooperation" OR "charity". Twenty-three articles were selected which met the inclusion criteria (papers written in English and studies whose methodology was based on experimental games and the theories, objectives, the main types of samples used, and main results were analyzed. The results show that the games used were the indirect reciprocity and public goods games, which may vary according to the objectives. It was found that reputation is a key variable that helps to promote cooperation. In turn, information on previous cooperation helps to build reputation, which is subsequently involved in the decision to cooperate with others. Finally, we highlight the need for more experimental studies that incorporate other explanatory variables and evaluate them in new contexts.

  13. Biomass Indirect Liquefaction Strategy Workshop Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-07-01

    This report is based on the proceedings of the U.S. Department of Energy Bioenergy Technologies Office Biomass Indirect Liquefaction Strategy Workshop. The workshop, held March 20–21, 2014, in Golden, Colorado, discussed and detailed the research and development needs for biomass indirect liquefaction. Discussions focused on pathways that convert biomass-based syngas (or any carbon monoxide, hydrogen gaseous stream) to liquid intermediates (alcohols or acids) and further synthesize those intermediates to liquid hydrocarbons that are compatible as either a refinery feed or neat fuel.

  14. CT findings at lupus mesenteric vasculitis

    International Nuclear Information System (INIS)

    Ko, S.F.; Lee, T.Y.; Cheng, T.T.; Ng, S.H.; Lai, H.M.; Cheng, Y.F.; Tsai, C.C.

    1997-01-01

    Purpose: To describe the spectrum of early CT findings of lupus mesenteric vasculitis (LMV) and to assess the utility of CT in the management of this uncommon entity. Methods: Abdominal CT was performed within 1-4 days (average 2.2 days) of the onset of severe abdominal pain and tenderness in 15 women with systemic lupus erythematosus. Prompt high-dose i.v. corticosteroid in 11 patients after the CT diagnosis of LMV was made. CT was performed after abdominal symptoms subsided. Results: Eleven cases revealed CT features suggestive of LMV including conspicuous prominence of mesentric vessels with palisade pattern or comb-like appearance (CT comb sign) supplying focal or diffuse dilated bowel loops (n=11), ascites with slightly increased peritoneal enhancement (n=11), small bowel wall thickening (n=10) with double halo or target sign (n=8). Follow-up CT before high-dose steroid therapy revealed complete or marked resolution of the abnormal CT findings. Conclusion: CT is helpful for confirming the diagnosis of LMV, especially the comb sign which may be an early sign. Bowel ischemia due to LMV is less ominous than previously expected, and the abnormal CT findings were reversible when early diagnosis and prompt i.v. steroid therapy could be achieved. (orig.)

  15. CT findings at lupus mesenteric vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Ko, S.F. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Lee, T.Y. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Cheng, T.T. [Chang Gung Medical College and Memorial Hospital, Dept. of Rheumatology, Kaohsiung Hsien (Taiwan); Ng, S.H. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Lai, H.M. [Chang Gung Medical College and Memorial Hospital, Dept. of Rheumatology, Kaohsiung Hsien (Taiwan); Cheng, Y.F. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Tsai, C.C. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan)

    1997-01-01

    Purpose: To describe the spectrum of early CT findings of lupus mesenteric vasculitis (LMV) and to assess the utility of CT in the management of this uncommon entity. Methods: Abdominal CT was performed within 1-4 days (average 2.2 days) of the onset of severe abdominal pain and tenderness in 15 women with systemic lupus erythematosus. Prompt high-dose i.v. corticosteroid in 11 patients after the CT diagnosis of LMV was made. CT was performed after abdominal symptoms subsided. Results: Eleven cases revealed CT features suggestive of LMV including conspicuous prominence of mesentric vessels with palisade pattern or comb-like appearance (CT comb sign) supplying focal or diffuse dilated bowel loops (n=11), ascites with slightly increased peritoneal enhancement (n=11), small bowel wall thickening (n=10) with double halo or target sign (n=8). Follow-up CT before high-dose steroid therapy revealed complete or marked resolution of the abnormal CT findings. Conclusion: CT is helpful for confirming the diagnosis of LMV, especially the comb sign which may be an early sign. Bowel ischemia due to LMV is less ominous than previously expected, and the abnormal CT findings were reversible when early diagnosis and prompt i.v. steroid therapy could be achieved. (orig.).

  16. The impact of the PET/CT in comparison with the same day contrast enhanced CT in breast cancer management

    International Nuclear Information System (INIS)

    Piperkova, E.; Raphael, B.; Altinyay, M.; Castellon, I.; Libes, R.; Abdel-Dayem, H.

    2006-01-01

    Full text: The aim of this study is to evaluate the impact of 18F-fluorodeoxyglucose FDG positron emission tomography with fused computerized tomography (PET/CT) in comparison with the same day contrast enhanced CT (CE-CT) in the breast cancer (BC) management. 68 studies in 48 BC patients, 8 for initial and 60 for restaging disease, after surgery, radiation/chemotherapy, for radiation therapy planning or evaluating treatment response were included. All patients underwent whole body PET/CT for diagnostic purposes followed by CE-CT diagnostic scans of selected body regions. PET/CT was performed approximately 90 minutes following 10-15 mCi of 18F-FDG on a GE Discovery PET/CT system. CT part acquired with low dose X-ray for localization and attenuation correction. The CE-CT was performed according to departmental protocol. Out of a total of 235 lesions in 68 PET/CT and CE-CT studies, 189 were concordant between PET/CT and CE-CT. However, there were 46 discordant lesions, which were verified by either follow-up or biopsy. PET/CT correctly identified 25 (True Positive-TP). CE-CT identified 2 TP lesions missed by PET/CT (False negative): one liver metastasis with necrosis, which is a known non-avid FDG, the other was a missed abdominal metastatic node, which did not change staging or treatment. PET/CT incorrectly identified 2 lesions (False Positive) while CE-CT incorrectly identified 17 FP. For evaluating treatment response in 40 follow up studies PET/CT reported complete response in 15, partial response in 11, stable disease in 2, progression in 5, and free of disease following surgery - in 7. The CE-CT described progression of the disease in 1 PET/CT true negative study and no progression in 2 TP PET/CT studies. In this study, PET/CT played more important role than CECT scans alone and provided an impact on the management of BC patients

  17. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    International Nuclear Information System (INIS)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo

    2016-01-01

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value

  18. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo [Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value.

  19. CT of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Sai, H; Kawamoto, S; Morimoto, K [Osaka Univ. (Japan). Faculty of Medicine

    1982-06-01

    CT was investigated in 125 cases of hepatocelluar carcinoma and 47 cases of metastatic hepatic neoplasm. The entire contour of each tumor was traced and the average CT value in the tumor was estimated. As a result, the CT value for hepatocellular carcinoma tended to be higher on plain CT and also after contrast enhancement. The CT findings seen frequently were as follows: capsule in 76 cases (60.8%) and septum in 67 cases (53.6%); tumor thrombus in portal vein in 39 cases (31.2%) and that in inferior vena cava in 3 cases (2.4%); localized enlargement of hepatic bile duct in 24 cases (19.2%). These findings were rarely seen in the cases of metastatic hepatic neoplasm. As a relatively outstanding feature of hepatic metastases, a double contour, like concentric circles or contour lines, with a relatively large inner circle or contour line, was found in 21 cases (44.7%). By paying attention to the change of CT value on contrast enhancement and the characteristic image of each case, hepatocellular carcinoma could be differentiated from metastatic hepatic neoplasm with high probability.

  20. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    It has been said that chronic subdural hematoma cannot be diagnosed by CT. In our cases, CT was used, and the results were described. According to the density of the picture, CT findings of chronic subdural hematoma could be classified into 3 types, those of higher density than that of the cerebral paranchyma, those of isodensity, and those of lower density than that of the cerebral parenchyma. The difference among them appeared to be due to variation in the fluid in hematoma, especially that in hemoglobin concentration. Chronic subdural hematoma was found in 27 of 388 cases of head trauma in which CT was undertaken in our department of surgery for last 2 years. It is difficult to differenciate this disease from subdural edema or subarachnoideal retention of the cerebrospinal fluid. In many cases, use of contrast medium added no change to the CT picture. Cerebral angiography is necessary for definite diagnosis of the disease. Chronic subdural hematoma gives more varieties of findings than other intracranial hematomas. However, if the film is very carefully read, CT is still useful for diagnosing this disease in spite of initially remarked difficulties. (Ueda, J.)

  1. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    Science.gov (United States)

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  2. CT-guided stereotactic neurosurgery

    International Nuclear Information System (INIS)

    Takizawa, Takaaki; Sato, Shoju; Matsumoto, Akira; Sano, Akira; Takahashi, Kazunori; Murakami, Yuji; Ohta, Kosuke

    1985-01-01

    Brown-Roberts-Wells stereotactic instruments were used for CT guided stereotactic surgery in 54 cases (65 operations). Stereotactic biopsy was done in 9 cases and successive regional chemotherapy was done in 3 cases. Stereotactic drainage was done in 2 cases of bacterial abcess, 3 cases of cystic neoplasm and 33 cases (43 operations) of intracerebral hematoma. CT guided stereotactic procedure was valuable for the correct cannulation to the center of the cavity. We tried to utilize CT image for the selection of targets for stereotactic functional neurosurgical procedures in 6 cases. In the cases of thalamotomy, the information derived from CT made the operation safer than that by contrast ventriculography alone. In all cases of electrode implantation for deep brain stimulation, accurate and precise electrode placement was achieved from CT images alone. This rapid and easy surgical technique was useful also for poor risk patients. (author)

  3. Thyroid lymphography-computed tomography (TLG-CT)

    International Nuclear Information System (INIS)

    Matsuyama, Koukichi

    1992-01-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author)

  4. [Accurate 3D free-form registration between fan-beam CT and cone-beam CT].

    Science.gov (United States)

    Liang, Yueqiang; Xu, Hongbing; Li, Baosheng; Li, Hongsheng; Yang, Fujun

    2012-06-01

    Because the X-ray scatters, the CT numbers in cone-beam CT cannot exactly correspond to the electron densities. This, therefore, results in registration error when the intensity-based registration algorithm is used to register planning fan-beam CT and cone-beam CT. In order to reduce the registration error, we have developed an accurate gradient-based registration algorithm. The gradient-based deformable registration problem is described as a minimization of energy functional. Through the calculus of variations and Gauss-Seidel finite difference method, we derived the iterative formula of the deformable registration. The algorithm was implemented by GPU through OpenCL framework, with which the registration time was greatly reduced. Our experimental results showed that the proposed gradient-based registration algorithm could register more accurately the clinical cone-beam CT and fan-beam CT images compared with the intensity-based algorithm. The GPU-accelerated algorithm meets the real-time requirement in the online adaptive radiotherapy.

  5. CT scanning in pediatric head trauma: correlation of clinical features with CT scan diagnosis

    International Nuclear Information System (INIS)

    Arkoncel, Mary Ann P.; Posadas, Ma. Belen A.

    1997-01-01

    A retrospective review was conducted on 205 cases of pediatric head trauma for which cranial computed tomography scans were done at the Makati Medical Center, to determine which clinical features might positively predict an abnormality on CT scan. The clinical findings of loss of consciousness, GCS < 12, vomiting headache, seizures, and focal abnormalities on Neurologic Examination were significantly associated with abnormal findings on CT scan. However, a significant discrepancy does exist as to how accurately clinical findings do in fact predict normal and abnormal CT scan findings. Such a discrepancy allows us to conclude that a more liberal use of CT Scanning in cases of pediatric head trauma must be stressed to insure proper diagnosis. This study shows that when a patient presents with the aforementioned positive signs and symptoms, or with a focal neurologic deficit, or in combination, a 60-100 % positive prediction of abnormal CT Scan can be made. However, prediction of normal CT Scan is only 0-40%. (Author)

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... or nurse at the time of the CT examination. If your child has a known contrast material ... be given to your child for the CT examination. top of page What does the CT equipment ...

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  8. CT diagnosis of acute spinal injury

    International Nuclear Information System (INIS)

    Ohhama, Mitsuru; Niimiya, Hikosuke; Kimura, Ko; Yamazaki, Gyoji; Nasu, Yoshiro; Shioya, Akihide

    1982-01-01

    CT pictures of 22 acute spinal injuries with damage of the spinal cord were evaluated. In the cases of spinal cord damage with bone injury, changes in the vertebral canal were fully observed by CT. In some of spinal cord damages without bone injury, narrowing of the vertebral canal was demonstrated by CT combined with CT myelography and reconstruction. Evaluation of CT number showed a high density area in damaged spinal cord in some cases. CT was thus considered to be useful as an adjunct diagnostic aid. (Ueda, J.)

  9. Positron emission tomography/computed tomography (PET/CT) and CT for N staging of non-small cell lung cancer.

    Science.gov (United States)

    Vegar Zubović, Sandra; Kristić, Spomenka; Hadžihasanović, Besima

    2017-08-01

    Aim The aim of this study is to investigate the possibilities of non-invasive diagnostic imaging methods, positron emission tomography/computed tomography (PET/CT) and CT, in clinical N staging of non-small cell lung cancer (NSCLC). Methods Retrospective clinical study included 50 patients with diagnosed NSCLC who have undergone PET/CT for the purpose of disease staging. The International association for the study of lung cancer (IASLC) nodal mapping system was used for analysis of nodal disease. Data regarding CT N-staging and PET/CT Nstaging were recorded. Two methods were compared using χ2 test and Spearman rank correlation coefficient. Results Statistical analysis showed that although there were some differences in determining the N stage between CT and PET/CT, these methods were in significant correlation. CT and PET/CT findings established the same N stage in 74% of the patients. In five patients based on PET/CT findings the staging was changed from operable to inoperable, while in four patients staging was changed from inoperable to operable. Conclusion PET/CT and CT are noninvasive methods that can be reliably used for N staging of NSCLC. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  10. Indirect Reciprocity : A Field Experiment

    NARCIS (Netherlands)

    van Apeldoorn, J.; Schram, A.

    2016-01-01

    Indirect reciprocity involves cooperative acts towards strangers, either in response to their kindness to third parties (downstream) or after receiving kindness from others oneself (upstream). It is considered to be important for the evolution of cooperative behavior amongst humans. Though it has

  11. Volume-artifact reduction modality by helical CT of the anterior, middle and posterior carnial fossae. Comparison with conventional CT; Volumen-Artefakt-Reduktionstechnik mittels Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube. Vergleich mit der konventionellen kranialen CT

    Energy Technology Data Exchange (ETDEWEB)

    Dorenbeck, U.; Finkenzeller, T.; Hill, K.; Feuerbach, S.; Link, J. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik

    2000-04-01

    Purpose: The object of this study was to determine the extent to which a new volume-artifact reduction (VAR) modality using helical CT was able to reduce artifacts in the anterior, middle and posterior fossae in comparison with conventional CT (sequential mode). Methods: In a prospective, randomized trial, 50 patients underwent helical CT (VAR) and 50 underwent sequential CT. The results were evaluated by three radiologists; influences on image quality where scaled between 1 (no artifact) and 4 (not assessable). Eight regions of the anterior, middle and posterior fossae were evaluated. Results: On average, artifacts were scaled at 2.5 in helical CT (VAR) and 3.1 in conventional CT. Significant differences were seen at the eyeball, anterior to the petrosol bone, at the internal occipital crest, and at the level of the transverse sinus (p<0.005). Conclusions: Helical CT with the VAR modality is superior to conventional, sequential CT in the area of the anterior, middle and posterior fossae. (orig.) [German] Ziel: Das Ziel dieser Studie war herauszufinden, inwieweit ein neuer Volumen-Artefakt-Reduktionsmodus (VAR) im Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube gegenueber der Einzelschicht-CT zu einer Artefaktverringerung beitragen kann. Methoden: In einer prospektiven randomisierten Studie wurden 50 Untersuchungen mit Spiral-CT und 50 mit Einzelschicht-CT bezueglich Artefakten verglichen. Die Auswertung erfolgte durch drei Radiologen, die Bildqualitaet wurde in einer Skala zwischen 1 (kein Artefakt) und 4 (Beurteilung der Region wegen Artefakten nicht moeglich) angegeben. Acht anatomische Regionen in der vorderen, mittleren und hinteren Schaedelgrube wurden auf Beeintraechtigung durch Artefakte untersucht. Ergebnisse: Im Durchschnitt betrug die Bewertung fuer die Artefaktbeeintraechtigung beim Spiral-CT (VAR) 2,5 gegenueber 3,1 bei der Einzelschicht-CT. Der VAR-Modus ermoeglichte in der mittleren und hinteren Schaedelgrube sowie im Balbus oculi

  12. Flat-detector computed tomography (FD-CT)

    International Nuclear Information System (INIS)

    Kalender, Willi A.; Kyriakou, Yiannis

    2007-01-01

    Flat-panel detectors or, synonymously, flat detectors (FDs) have been developed for use in radiography and fluoroscopy with the defined goal to replace standard X-ray film, film-screen combinations and image intensifiers by an advanced sensor system. FD technology in comparison to X-ray film and image intensifiers offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. Respective efforts date back a few years only, but FD-CT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. FD-CT provides a very efficient way of combining two-dimensional (2D) radiographic or fluoroscopic and 3D CT imaging. In addition, FD technology made its way into a number of dedicated CT scanner developments, such as scanners for the maxillo-facial region or for micro-CT applications. This review focuses on technical and performance issues of FD technology and its full range of applications for CT imaging. A comparison with standard clinical CT is of primary interest. It reveals that FD-CT provides higher spatial resolution, but encompasses a number of disadvantages, such as lower dose efficiency, smaller field of view and lower temporal resolution. FD-CT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations; but it has already proven unique for a number of dedicated CT applications, offering distinct practical advantages, above all the availability of immediate CT imaging in the interventional suite or the operating room. (orig.)

  13. Neutron-capture Cross Sections from Indirect Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Escher, J E; Burke, J T; Dietrich, F S; Ressler, J J; Scielzo, N D; Thompson, I J

    2011-10-18

    Cross sections for compound-nuclear reactions play an important role in models of astrophysical environments and simulations of the nuclear fuel cycle. Providing reliable cross section data remains a formidable task, and direct measurements have to be complemented by theoretical predictions and indirect methods. The surrogate nuclear reactions method provides an indirect approach for determining cross sections for reactions on unstable isotopes, which are difficult or impossible to measure otherwise. Current implementations of the method provide useful cross sections for (n,f) reactions, but need to be improved upon for applications to capture reactions.

  14. 42 CFR 412.322 - Indirect medical education adjustment factor.

    Science.gov (United States)

    2010-10-01

    ... Payment System for Inpatient Hospital Capital Costs Basic Methodology for Determining the Federal Rate for Capital-Related Costs § 412.322 Indirect medical education adjustment factor. (a) Basic data. CMS.... The indirect teaching adjustment factor equals [e (raised to the power of .2822×the ratio of residents...

  15. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  16. Manifestations of Indirect Self-Destructiveness and Dimensions of Emotional Intelligence.

    Science.gov (United States)

    Tsirigotis, Konstantinos; Łuczak, Joanna

    2016-09-01

    While indirect self-destructiveness exerts a rather negative influence on the life and psychological and social functioning of the individual, emotional intelligence may have a favourable effect. The aim of this study has been to explore possible relationships between manifestations of indirect self-destructiveness and dimensions of emotional intelligence. A population of 260 individuals (130 females and 130 males) aged 20-30 (mean age of 24.5) was studied by using the Polish version of the Chronic Self-Destructiveness Scale and INTE, i.e., the Polish version of the Assessing Emotions Scale. Manifestations of indirect self-destructiveness show many significant correlations with variables of the INTE, and those correlations are negative. Generally, it can be said that low emotional intelligence is associated with poor psychosocial and social functioning, which, in turn, is associated with indirect self-destructiveness and its manifestations. It seems advisable to use emotional intelligence in the prophylactic and therapeutic work with individuals suffering from various types of disorders, especially the syndrome of indirect self-destructiveness.

  17. Direct and indirect pathways for choosing objects and actions.

    Science.gov (United States)

    Hikosaka, Okihide; Kim, Hyoung F; Amita, Hidetoshi; Yasuda, Masaharu; Isoda, Masaki; Tachibana, Yoshihisa; Yoshida, Atsushi

    2018-02-23

    A prominent target of the basal ganglia is the superior colliculus (SC) which controls gaze orientation (saccadic eye movement in primates) to an important object. This 'object choice' is crucial for choosing an action on the object. SC is innervated by the substantia nigra pars reticulata (SNr) which is controlled mainly by the caudate nucleus (CD). This CD-SNr-SC circuit is sensitive to the values of individual objects and facilitates saccades to good objects. The object values are processed differently in two parallel circuits: flexibly by the caudate head (CDh) and stably by the caudate tail (CDt). To choose good objects, we need to reject bad objects. In fact, these contrasting functions are accomplished by the circuit originating from CDt: The direct pathway focuses on good objects and facilitates saccades to them; the indirect pathway focuses on bad objects and suppresses saccades to them. Inactivation of CDt deteriorated the object choice, because saccades to bad objects were no longer suppressed. This suggests that the indirect pathway is important for object choice. However, the direct and indirect pathways for 'object choice', which aim at the same action (i.e., saccade), may not work for 'action choice'. One possibility is that circuits controlling different actions are connected through the indirect pathway. Additional connections of the indirect pathway with brain areas outside the basal ganglia may also provide a wider range of behavioral choice. In conclusion, basal ganglia circuits are composed of the basic direct/indirect pathways and additional connections and thus have acquired multiple functions. © 2018 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  18. CT of abdominal abscesses

    International Nuclear Information System (INIS)

    Korobkin, M.T.

    1987-01-01

    The imaging search for a suspected abdominal abscess is common in hospitalized patients, especially after recent abdominal surgery. This paper examines the role of CT in the detection, localization, and treatment of abdominal abscess. The accuracy, limitations, and technical aspects of CT in this clinical setting are discussed. The diagnosis of an abscess is based on the demonstration of a circumscribed abnormal fluid collection. Although percutaneous aspiration with gram stain and culture is usually indicated to differentiate abscess from other fluid collections, the CT-based detection of extraluminal gas bubbles makes the diagnosis of an abscess highly likely. CT is compared with conventional radiographic studies, US, and radio-nuclide imaging. Specific CT and clinical features of abscesses in the following sites are emphasized: subphrenic space, liver, pancreas, kidneys, psoas muscle, appendix, and colonic diverticula. Most abdominal abscesses can be successfully treated with percutaneous drainage techniques. The techniques, results, and limitations of percutaneous abscess drainage are reviewed

  19. CT of tracheal agenesis

    International Nuclear Information System (INIS)

    Strouse, Peter J.; Hernandez, Ramiro J.; Newman, Beverley

    2006-01-01

    Tracheal agenesis is a rare and usually lethal anomaly. In the past, opaque contrast medium was injected via the esophagus to demonstrate the anatomy. To demonstrate the utility of helical and multidetector CT in delineating the aberrant anatomy in newborns with tracheal agenesis. Four newborns with tracheal agenesis were identified from three institutions. Imaging studies and medical records were reviewed. Each child was imaged with chest radiography. One child was imaged on a single-detector helical CT scanner and the other three on multidetector scanners. Helical and multidetector CT with 2D and 3D reconstructions clearly delineated the aberrant tracheobronchial and esophageal anatomy in each infant. Minimum intensity projection reformatted CT images were particularly helpful. One infant each had type I and type II tracheal agenesis. Two infants had type III tracheal agenesis. All four infants died. CT is a useful tool for delineating the aberrant anatomy of newborns with tracheal agenesis and thus helps in making rational clinical decisions. (orig.)

  20. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    In our cases of acute and subacute subdural hematoma, the use of CT was evaluated. In our department of surgery, acute subdural hematoma was found in 46 of 388 patients of head trauma who underwent CT. Acute subdural hematoma, like epidural hematoma was usually visualized as a high-density area along the cranial inner table, and this was easily differenciated from epidural hematoma because of difference in shape from the other. The picture of acute subdural hematoma was occasionally confused with that of intracerebral hematoma or cerebral contusion. Single use of CT does not differenciate subacute subdural hematoma from chronic subdural hematoma. However, CT usually visualized acute hematoma as a high-density area, showing the extent of hematoma. Comparison of the thickness of hematoma with the axis deviation of the median part such as the 3rd cerebral ventricle suggested severity of cerebral edema. CT also revealed bilateral or multiple lesions of cerebral contusion or intracerebral hematoma. (Ueda, J.)

  1. CT of laryngeal trauma

    International Nuclear Information System (INIS)

    Jeffrey, R.B.

    1986-01-01

    Computed tomography has made a significant contribution to the radiologic assessment of the injured larynx. CT is an accurate, noninvasive modality that can rapidly diagnose both soft tissue and cartilaginous injuries. CT of the larynx involves a minimal degree of patient manipulation and discomfort and can be performed in conjunction with CT evaluation of intracranial or facial injuries. Conventional radiologic studies (anteroposterior and lateral soft tissue films of the neck, tomograms, or xerograms) are capable of demonstrating some cartilaginous fractures but are of limited value in defining the extent of soft tissue injury. In the acute trauma setting, laryngography is often technically difficult to perform because of patient discomfort and inability to cooperate. Although the overall experience is somewhat limited, CT appears to overcome many of the limitations of these conventional radiologic methods. The following is a discussion of the role of CT scanning in evaluating injuries to the larynx and cervical soft tissues

  2. Congenital bronchopulmonary malformation: CT histopathological correlation.

    Science.gov (United States)

    Kyncl, Martin; Koci, Martin; Ptackova, Lea; Hornofova, Ludmila; Ondrej, Fabian; Snajdauf, Jiri; Pychova, Marcela

    2016-12-01

    This study evaluated the accuracy of postnatal computed tomography (CT) imaging in the identification of congenital bronchopulmonary malformation (BPM) in comparison with histopathological analysis. CT scans of prenatally diagnosed BPMs from 24 patients with available histology were analysed retrospectively. The CT images were reviewed blinded to histological findings by two radiologists. Specific diagnosis was assigned based on predetermined criteria. The accuracy of CT was evaluated. The agreement rate in CT diagnosis between two radiologists was 100%. In 75% the lesions were located in the lower lobes. An overlap of 71% in CT and histopathological diagnoses was reached. The least matching diagnosis was type 2 CPAM. Contrast enhanced chest CT is very accurate in characterizing the BPM spectrum and provides important information on lesion type and structure.

  3. Ancestry of indirect techniques for X-ray imaging

    International Nuclear Information System (INIS)

    Mertz, L.

    1989-01-01

    Historical citations concerning the origins of coded-aperture imaging are corrected. Another scheme is presented for synthetic indirect imaging to overcome certain shortcomings of simple coded apertures. Pairs of Fresnel zone patterns are used to create moire patterns that can be Fourier transformed for image reconstruction. It is also conjectured that image reconstructions that are constrained to be nonnegative should overcome certain complaints concerning indirect imaging. 20 refs

  4. Heard it through the grapevine: indirect networks and employee creativity.

    Science.gov (United States)

    Hirst, Giles; Van Knippenberg, Daan; Zhou, Jing; Quintane, Eric; Zhu, Cherrie

    2015-03-01

    Social networks can be important sources of information and insights that may spark employee creativity. The cross-fertilization of ideas depends not just on access to information and insights through one's direct network-the people one actually interacts with--but at least as much on access to the indirect network one's direct ties connect one to (i.e., people one does not interact with directly, but with whom one's direct ties interact). We propose that the reach efficiency of this indirect network--its nonredundancy in terms of interconnections--is positively related to individual creativity. To help specify the boundaries of this positive influence of the indirect network, we also explore how many steps removed the indirect network still adds to creativity. In addition, we propose that the efficiency (nonredundancy) of one's direct network is important here, because more efficient direct networks give one access to indirect networks with greater reach efficiency. Our hypotheses were supported in a multilevel analysis of multisource survey data from 223 sales representatives nested within 11 divisions of a Chinese pharmaceutical company. This analysis also showed that the creative benefits of reach efficiency were evident for 3 and 4 degrees of separation but were greatest for indirect ties that depend only on one's direct ties. PsycINFO Database Record (c) 2015 APA, all rights reserved.

  5. An improved recommendation algorithm via weakening indirect linkage effect

    International Nuclear Information System (INIS)

    Chen Guang; Qiu Tian; Shen Xiao-Quan

    2015-01-01

    We propose an indirect-link-weakened mass diffusion method (IMD), by considering the indirect linkage and the source object heterogeneity effect in the mass diffusion (MD) recommendation method. Experimental results on the MovieLens, Netflix, and RYM datasets show that, the IMD method greatly improves both the recommendation accuracy and diversity, compared with a heterogeneity-weakened MD method (HMD), which only considers the source object heterogeneity. Moreover, the recommendation accuracy of the cold objects is also better elevated in the IMD than the HMD method. It suggests that eliminating the redundancy induced by the indirect linkages could have a prominent effect on the recommendation efficiency in the MD method. (paper)

  6. CT findings of inoperable lung carcinoma

    International Nuclear Information System (INIS)

    Gay, S.B.; Black, W.C.

    1987-01-01

    CT is useful in the evaluation of patients with newly diagnosed or highly suspected lung cancer. The principal role of CT is to screen those patients with metastatic disease beyond the hili from an attempt at curative thoracotomy. While CT is regarded as very sensitive, it is not considered highly specific, and thus a surgical procedure is usually recommended for definitive diagnosis of most ''positive'' CT findings. However, the authors demonstrate a few characteristic CT findings that are highly predictive of unresectable metastatic disease. These CT findings include massive mediastinal lymphadenopathy, diffuse mediastinal infiltration, pericardial involvement, vascular encasement, and advanced chest wall invasion

  7. Thyroid lymphography-computed tomography (TLG-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, Koukichi (Kansai Medical Univ., Moriguchi, Osaka (Japan))

    1992-10-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author).

  8. CT diagnosis of hepatoma

    Energy Technology Data Exchange (ETDEWEB)

    Itai, Yuji [Tokyo Univ. (Japan). Faculty of Medicine

    1982-04-01

    In hepatocellular carcinoma, present status of CT diagnosis was discussed. Hepatocellular carcinoma is sometimes imaged in same concentration as that of surrounding tissues, and the detection rate ranged from 79 to 94%. The rate of differential diagnosis between primary and metastatic carcinoma was only 83% (includes 22% of false diagnosis) using contrast enhancement. The rates of detection of hepatocellular carcinoma and metastatic one were also only 87% and 75%, respectively, even by the combined use of arterial infusion CT and dynamic CT. However, the CT images is reproducible, and is supplemented by the information of US. Thus, the combination of these methods is useful in diagnosing the presence, extension, and nature of liver carcinoma.

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... What is Children's CT? What are some common uses of the procedure? How should we prepare for the CT scan? What does the CT equipment look like? How does the procedure work? How is the procedure performed? What will my ...

  10. The role of CT in diagnosing small hepatic tumors; Usefulness of table incremental dynamic CT (ICT)

    Energy Technology Data Exchange (ETDEWEB)

    Usuki, Noriaki; Daikokuya, Hideo; Fukuda, Haruyuki; Saiwai, Shigeo; Nakajima, Hideyuki; Miyamoto, Takeshi; Kudo, Masatoshi (Kobe General Hospital, Hyogo (Japan))

    1992-11-01

    Twenty-seven cases of small hepatic tumors were examined by MRI and CT (ICT). MRI was more sensitive than plain and contrast CT. But ICT could detect more small lesions than MRI. CT is not more superior modality than MRI untill ICT is performed. It is concluded ICT should be done when diagnosing small hepatic tumors by CT. (author).

  11. CT of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    Itoh, Harumi; Murata, Kiyoshi; Todo, Giro

    1987-01-01

    While the theory of chest radiographic interpretation in diagnosing diffuse pulmonary diseases has not yet been established, X-ray computed tomography (CT), having intrinsic high contrast resolution and improved spatial resolution, has proved to offer important imformation concerning the location and invasion of diffuse pulmonary lesions. This study related to CT-pathologic correlation, focusing on perivascular interstitial space and secondary pulmonary lobule at macroscopic levels. The perivascular interstitial space was thickened as a result of the infiltration of cancer, granulomas, and inflammatory cells. This finding appeared as irregular contour of the blood vessel on CT. Centrilobular nodules were distributed at the tip of the bronchus or pulmonary artery on CT. The distance from the terminal and respiratory bronchioles to the lobular border was 2 to 3 mm. Lobular lesions were delineated as clear margin on CT. Contribution of these CT features to chest radiographic interpretation must await further studies. (Namekawa, K.)

  12. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  13. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  14. Indirect Comprehensive Review Board (ICRB). Final Report

    International Nuclear Information System (INIS)

    1996-12-01

    Lockheed Martin Idaho Technologies Company (LMITCO) used a systems engineering approach to take the first step toward defining a requirements baseline for all indirect work at the Idaho National Engineering Laboratory. The intent of this effort was to define the requirements for indirect work, identify the activities necessary to meet the requirements, and to produce defensible cost estimates for the work. The result of this effort is a scrubbed-down, defensible budget for all indirect work in FY 1997. Buying power for each dollar of direct work was increased by $.02. Recommendations are identified for improvements to this process in FY 1998. The purpose of this report is twofold. First is to report the final results of the 1996 ICRB process, and second is to document the process used such that incremental improvements may be made in future years. Objectives, processes, and approaches are described to provide a trail for future boards. Appendices contain copies of board composition, documentation of the process, as well as the actual training materials

  15. Interactive indirect illumination using adaptive multiresolution splatting.

    Science.gov (United States)

    Nichols, Greg; Wyman, Chris

    2010-01-01

    Global illumination provides a visual richness not achievable with the direct illumination models used by most interactive applications. To generate global effects, numerous approximations attempt to reduce global illumination costs to levels feasible in interactive contexts. One such approximation, reflective shadow maps, samples a shadow map to identify secondary light sources whose contributions are splatted into eye space. This splatting introduces significant overdraw that is usually reduced by artificially shrinking each splat's radius of influence. This paper introduces a new multiresolution approach for interactively splatting indirect illumination. Instead of reducing GPU fill rate by reducing splat size, we reduce fill rate by rendering splats into a multiresolution buffer. This takes advantage of the low-frequency nature of diffuse and glossy indirect lighting, allowing rendering of indirect contributions at low resolution where lighting changes slowly and at high-resolution near discontinuities. Because this multiresolution rendering occurs on a per-splat basis, we can significantly reduce fill rate without arbitrarily clipping splat contributions below a given threshold-those regions simply are rendered at a coarse resolution.

  16. Indirect carotid cavernous fistula mimicking ocular myasthenia.

    Science.gov (United States)

    Leishangthem, Lakshmi; Satti, Sudhakar Reddy

    2017-10-19

    71-year-old woman with progressive left-sided, monocular diplopia and ptosis. Her symptoms mimicked ocular myasthenia, but she had an indirect carotid cavernous fistula (CCF). She was diagnosed with monocular myasthenia gravis (negative acetylcholinesterase antibody) after a positive ice test and started on Mestinon and underwent a thymectomy complicated by a brachial plexus injury. Months later, she developed left-sided proptosis and ocular bruit. She was urgently referred to neuro-interventional surgery and was diagnosed with an indirect high-flow left CCF, which was treated with Onyx liquid and platinum coil embolisation. Mestinon was discontinued. Her ophthalmic symptoms resolved. However, she was left with a residual left arm and hand hemiparesis and dysmetria secondary to a brachial plexus injury. Indirect CCF usually can present with subtle and progressive symptoms leading to delayed diagnosis or misdiagnosis. It is important for ophthalmologists to consider this differential in a patient with progressive ocular symptoms. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Acute pancreatitis: clinical vs. CT findings

    International Nuclear Information System (INIS)

    Hill, M.C.; Barkin, J.; Isikoff, M.B.; Silver stein, W.; Kalser, M.

    1982-01-01

    In a prospective study of 91 patients with acute pancreatitis, computed tomographic (CT) findings were correlated with the clinical type of acute pancreatitis. In acute edematous pancreatitis (63 patients; 16 with repeat CT), CT was normal (28%) or showed inflammation limited to the pancreas (61%). Phlegmonous changes were present in 11%, including one patient with focal pancreatic hemorrhage, indicating that clinically unsuspected hemorrhagic pancreatitis can occur. In acute necrotizing (hemorrhagic, suppurative) pancreatitis (nine patients; eight with repeat CT), no patient had a normal CT scan and 89% had phlegmonous changes. One patient had hemorrhagic pancreatitis and three had abscesses. In acute exacerbation of chronic pancreatitis (10 patients; three with repeat CT), there were pancreatic calcifications (70%), a focal mass (40%), and pancreatic ductal dilation (30%). On follow-up CT, the findings of acute pancreatitis did not always disappear with resolution of the clinical symptons. This was especialy true of phlegmonous pancreatitis, where the CT findings could persist for months

  18. Multidetector CT of the colon

    International Nuclear Information System (INIS)

    Luboldt, W.; Hoepffner, N.; Holzer, K.

    2003-01-01

    Multidetector technology, enabling faster imaging, higher spatial resolution and reduction in radiation dose, increases the role of CT in colonic diagnostic. The higher spatial resolution in the z-direction also changes the way to analyze the images. Instead of reading axial sections, now the colon can be systematically assessed in 3D by scrolling through multiplanar reconstructions or in CT colonography by virtual endoscopy. With ongoing improvements in computer-aided diagnosis CT colonography becomes an alternative to fiberoptic colonocopy for screening (http://www.multiorganscreening.org). In this article we propose a CT examination protocol for the colon, describe the typical imaging findings of different colonic diseases, and summarize the current status of CT colonography. (orig.)

  19. CT examination of the kidneys

    International Nuclear Information System (INIS)

    Handa, Youji; Ishida, Ken; Arita, Takeshi; Ishine, Kenji; Tezen, Takashi; Ohta, Nobuhiro

    1985-01-01

    Plain CT scanning of the kidney was performed in 16 patients with renal failure whose basic renal disorder had been not necessarily known beforehand. The findings of the CT examination were composed of renal atrophy of various degree (12 cases), cystic lesions (8 cases), polycystic renal disease (one case), nephrosclerosis (2 cases), hydronephrosis (2 cases), ureter and renal stones (one case), and normal CT profile (2 cases). Being based on these CT findings and other clinical informations, basic renal disorders could be either presumed or confirmed. It was concluded that plain CT scanning of the kidney was useful to decide a method of treatment and to estimate prognosis in patients with renal failure. (author)

  20. A case misdiagnosed as bilateral abducens palsy

    International Nuclear Information System (INIS)

    Takeda, Naoya; Kuwamura, Keiichi; Shirataki, Kunio; Tamaki, Norihiko; Matsumoto, Satoshi

    1984-01-01

    A 66-year-old male was admitted to our neurosurgical floor because of double vision and gait disturbance. Neurological examinations revealed bilateral 6th nerve palsy with both eyes pointing toward the midline. Initially, using a tentative diagnosis of intracranial mass lesions, especially localized at the base of the skull, computerized tomography of the head, cerebral angiography, orbital venography, and metrizamide CT cisternography were performed; the findings were normal. An orbital CT scan showed an enlargement of the bilateral medial rectus muscles, and the thyroid functions of T 3 and T 4 and the T 3 uptake were all elevated, which was compatible with the diagnosis of Graves' disease. The limitations of both eyeballs were considered to be due not to the 6th nerve palsy, but to the hypertrophy of the bilateral medial rectus muscles. We neurosurgeons should recall Graves' disease as well as intracranial lesions, cerebrovascular disease, and post-traumatic sequelae when examining a patient who presents limitations of external ocular movement. (author)

  1. Cerebral venous thrombosis

    International Nuclear Information System (INIS)

    Soralova, T.; Sevcikova, H.; Petersky, D.

    2014-01-01

    We decided to process this theme due to its nonspecific clinical features as they often cause diagnostic problems not only to clinicians but also to diagnostic. It is important to think of this disease mainly in young women who administer hormonal contraception. Imaging methods play the crucial role in diagnostic of cerebral venous sinus thrombosis. The gold standard is a native CT of brain which shows the venous sinus thrombosis as a hyperdense lesion in the locus of the sinus (dense triangle sign), CT venography shows the sinus thrombosis as a defect in a contrast filling of the venous sinus (empty delta sign). Other investigative methods are magnetic resonance imaging or MRA. In short we also mention quite a rare but more serious thrombosis of profound cerebral veins v. cerebri magna-Galeni, vv. cerebri internae). The importance of early diagnostic and non specificity of symptoms is presented in 3 clinical cases that are the part of this work. (author)

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  3. Do SNOMED CT Relationships Qualify?

    NARCIS (Netherlands)

    Cornet, Ronald

    2008-01-01

    An important feature of SNOMED CT is post-coordination, which is enabled as SNOMED CT specifies refinability of target concepts of relationships. In this paper the use of refinable relationships in SNOMED CT is analysed, and the interplay between refinable and defining relationships. Refinability is

  4. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  5. {sup 18}F-FDG PET/CT and contrast-enhanced CT findings of pulmonary cryptococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Si-yun, E-mail: wang_shuxia@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Chen, Gang, E-mail: cgggh@outlook.com [Department of Thoracic Surgery, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Luo, Dong-lan, E-mail: 695532870@qq.com [Department of Pathology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Shao, Dan, E-mail: shaodan501@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Liu, En-tao, E-mail: GDGH2015@gmail.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Sun, Taotao, E-mail: sunmoodsdaisy@bjmu.edu.cn [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Wang, Shu-Xia, E-mail: wsyggh@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China)

    2017-04-15

    Purpose: Pulmonary cryptococcosis is an uncommon cause of pulmonary nodules in non-AIDS patients. This study reports the {sup 18}F-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG PET/CT) and contrast-enhanced CT (CE-CT) findings of 42 patients with pulmonary cryptococcosis. Materials and methods: A retrospective review of the {sup 18}F-FDG PET/CT and CE-CT findings of 42 patients with histologically proven pulmonary cryptococcosis was conducted. All patients underwent PET/CT and CE-CT in the same session. The CT diagnosis was based on the location, morphological features, and enhancement of lesions. The PET/CT findings were recorded, and clinical data and surgical and histopathological findings were collected. Results: The results of the PET scans revealed that 37 (88%) of 42 patients showed higher FDG uptake, and 5 (12%) patients demonstrated lower FDG uptake than the mediastinal blood pool. The maximum standardized uptake value (SUV) of pulmonary cryptococcosis ranged from 1.4 to 13.0 (average: 5.7 ± 3.3, median 4.9). A single nodular pattern was the most prevalent pattern observed and was found in 29 (69%) patients. This pattern was followed by scattered nodular (n = 4, 10%), clustered nodular (n = 3, 7%), mass-like (n = 3, 7%), and bronchopneumonic (n = 3, 7%) patterns. The most frequent pattern of immunocompetent patients was the single nodular pattern (29 of 33, 88%). Immunocompromised patients most frequently pattern exhibited mass-like (3 of 9, 33%) and bronchopneumonic (3 of 9, 33%) patterns. Conclusion: Pulmonary cryptococcosis most commonly appears as single nodules in immunocompetent patients. Mass-like and bronchopneumonic patterns were common in immunocompromised patients. In 88% of patients, lung lesions showed high FDG uptake, thus mimicking a possible malignant condition.

  6. The Indirect Costs of Financial Distress in Indonesia

    Directory of Open Access Journals (Sweden)

    Wijantini Wijantini

    2007-06-01

    Full Text Available This paper presents quantitative estimates of the indirect cost of financial distress and its determinants. In order to measure the cost, this study estimates the annualized changes in industry-adjusted operation profit and sales from a year before the onset of distress to the resolution year. Using those approaches, the median of indirect financial distress cost is estimated between three and 11 percent annually. To the extent that the direct cost of financial distress reduces reported operating income, the estimated costs are overstated. The simple regressions analysis suggest that the indirect cost of financial distress significantly increases with size, leverage, number of creditors, and poor industry performance, but is not related to degree of bank loan reliance. The findings provide a weak support for the financial distress theory which suggests that conflicts of interest render the costs of financial distress.

  7. Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography

    International Nuclear Information System (INIS)

    Wang Min; Qi Hengtao; Wang Ximing; Wang Tao; Chen, Jiu-Hong; Liu Cheng

    2009-01-01

    Objective: To evaluate dose performance and image quality of 64-slice dual source CT (DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA). Methods: 100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP). Results: At low heart rates ( 0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P 70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT.

  8. Patient-specific dose estimation for pediatric chest CT

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P. [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Global Applied Science Laboratory, GE Healthcare, Waukesha, Wisconsin 53188 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 and Department of Radiology, Division of Pediatric Radiology, Duke University Medical Center, Durham North Carolina 27710 (United States)

    2008-12-15

    Current methods for organ and effective dose estimations in pediatric CT are largely patient generic. Physical phantoms and computer models have only been developed for standard/limited patient sizes at discrete ages (e.g., 0, 1, 5, 10, 15 years old) and do not reflect the variability of patient anatomy and body habitus within the same size/age group. In this investigation, full-body computer models of seven pediatric patients in the same size/protocol group (weight: 11.9-18.2 kg) were created based on the patients' actual multi-detector array CT (MDCT) data. Organs and structures in the scan coverage were individually segmented. Other organs and structures were created by morphing existing adult models (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. Organ and effective dose of these patients from a chest MDCT scan protocol (64 slice LightSpeed VCT scanner, 120 kVp, 70 or 75 mA, 0.4 s gantry rotation period, pitch of 1.375, 20 mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated to simulate radiation transport in the same CT system. The seven patients had normalized effective dose of 3.7-5.3 mSv/100 mAs (coefficient of variation: 10.8%). Normalized lung dose and heart dose were 10.4-12.6 mGy/100 mAs and 11.2-13.3 mGy/100 mAs, respectively. Organ dose variations across the patients were generally small for large organs in the scan coverage (<7%), but large for small organs in the scan coverage (9%-18%) and for partially or indirectly exposed organs (11%-77%). Normalized effective dose correlated weakly with body weight (correlation coefficient: r=-0.80). Normalized lung dose and heart dose correlated strongly with mid-chest equivalent diameter (lung: r=-0.99, heart: r=-0.93); these strong correlation relationships can be used to estimate patient-specific organ

  9. Early small-bowel ischemia: dual-energy CT improves conspicuity compared with conventional CT in a swine model.

    Science.gov (United States)

    Potretzke, Theodora A; Brace, Christopher L; Lubner, Meghan G; Sampson, Lisa A; Willey, Bridgett J; Lee, Fred T

    2015-04-01

    To compare dual-energy computed tomography (CT) with conventional CT for the detection of small-bowel ischemia in an experimental animal model. The study was approved by the animal care and use committee and was performed in accordance with the Guide for Care and Use of Laboratory Animals issued by the National Research Council. Ischemic bowel segments (n = 8) were created in swine (n = 4) by means of surgical occlusion of distal mesenteric arteries and veins. Contrast material-enhanced dual-energy CT and conventional single-energy CT (120 kVp) sequences were performed during the portal venous phase with a single-source fast-switching dual-energy CT scanner. Attenuation values and contrast-to-noise ratios of ischemic and perfused segments on iodine material-density, monospectral dual-energy CT (51 keV, 65 keV, and 70 keV), and conventional 120-kVp CT images were compared. Linear mixed-effects models were used for comparisons. The attenuation difference between ischemic and perfused segments was significantly greater on dual-energy 51-keV CT images than on conventional 120-kVp CT images (mean difference, 91.7 HU vs 47.6 HU; P conventional CT by increasing attenuation differences between ischemic and perfused segments on low-kiloelectron volt and iodine material density images. © RSNA, 2014.

  10. Chest Computed Tomography (CT) Immediately after CT-Guided Transthoracic Needle Aspiration Biopsy as a Predictor of Overt Pneumothorax

    Science.gov (United States)

    Noh, Tae June; Lee, Chang Hoon; Kang, Young Ae; Kwon, Sung-Youn; Yoon, Ho-Il; Kim, Tae Jung; Lee, Kyung Won; Lee, Jae Ho

    2009-01-01

    Background/Aims This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation. Methods Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients. Results Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax. Conclusions CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax. PMID:19949733

  11. Dynamic CT of the renal parenchyma

    International Nuclear Information System (INIS)

    Ohyama, Yukio; Imanishi, Yoshimasa; Ishikawa, Tohru; Fujii, Masamichi; Uji, Teruyuki

    1985-01-01

    Normal renal dynamic CT findings of 57 cases were analysed in termes of sequential change of renal parenchymal CT image. Cortex, outer medulla and inner medulla were delineated and their sequential CT image was well correlated with the anatomicophysiological character of the kidney. Dynamic CT of 32 abnormal cases showed abnormal sequential CT findings explaining the mechanism of the abnormalities. Especially, delayed enhancement of renal cortex was noted in 17 of 19 kidneys with arterial obstruction and delayed enhancement of renal medulla in 22 of 25 cases with renal dysfunction. Compaired with excretory urography in 11 cases with renal dysfunction, advantage of dynamic CT were noted. (author)

  12. Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

    Science.gov (United States)

    Yeh, Benjamin M; FitzGerald, Paul F; Edic, Peter M; Lambert, Jack W; Colborn, Robert E; Marino, Michael E; Evans, Paul M; Roberts, Jeannette C; Wang, Zhen J; Wong, Margaret J; Bonitatibus, Peter J

    2017-04-01

    The introduction of spectral CT imaging in the form of fast clinical dual-energy CT enabled contrast material to be differentiated from other radiodense materials, improved lesion detection in contrast-enhanced scans, and changed the way that existing iodine and barium contrast materials are used in clinical practice. More profoundly, spectral CT can differentiate between individual contrast materials that have different reporter elements such that high-resolution CT imaging of multiple contrast agents can be obtained in a single pass of the CT scanner. These spectral CT capabilities would be even more impactful with the development of contrast materials designed to complement the existing clinical iodine- and barium-based agents. New biocompatible high-atomic number contrast materials with different biodistribution and X-ray attenuation properties than existing agents will expand the diagnostic power of spectral CT imaging without penalties in radiation dose or scan time. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Suspected pulmonary embolism and deep venous thrombosis: A comprehensive MDCT diagnosis in the acute clinical setting

    International Nuclear Information System (INIS)

    Salvolini, Luca; Scaglione, Mariano; Giuseppetti, Gian Marco; Giovagnoni, Andrea

    2008-01-01

    Both pulmonary arterial and peripheral venous sides of venous thromboembolism (VTE) can now be efficiently and safely investigated by multi-detector CT (MDCT) at the same time by a combined CT angiography/CT venography protocol. In the emergency setting, the use of such a single test for patients suspected of suffering from VTE on a clinical grounds may considerably shorten and simplify diagnostic algorithms. The selection of patients to be submitted to MDCT must follow well-established clinical prediction rules in order to avoid generalized referral to CT on a generic clinical suspicion basis and excessive population exposure to increased ionizing radiation dose, especially in young patients. Clinical and anatomical wide-panoramic capabilities of MDCT allow identification of underlying disease that may explain patients' symptoms in a large number of cases in which VTE is not manifest. The analysis of MDCT additional findings on cardiopulmonary status and total thrombus burden can lead to better prognostic stratification of patients and influence therapeutic options. Some controversial points such as optimal examination parameters, clinical significance of subsegmentary emboli, CT pitfalls and/or possible falsely positive diagnoses, and outcome of untreated patients in which VTE has been excluded by MDCT without additional testing, must of course be taken into careful consideration before the definite role of comprehensive MDCT VTE 'one-stop-shop' diagnosis in everyday clinical practice can be ascertained

  14. Suspected pulmonary embolism and deep venous thrombosis: A comprehensive MDCT diagnosis in the acute clinical setting

    Energy Technology Data Exchange (ETDEWEB)

    Salvolini, Luca [Radiology Department, ' Umberto I' Hospital - Ospedali Riuniti - ' Politecnica delle Marche' University, Via Conca, 60020 Ancona (Italy)], E-mail: lucasalvolini@alice.it; Scaglione, Mariano [Emergency and Trauma CT Section, Department of Radiology, Cardarelli Hospital, Via G. Merliani 31, 80127 Naples (Italy); Giuseppetti, Gian Marco; Giovagnoni, Andrea [Radiology Department, ' Umberto I' Hospital - Ospedali Riuniti - ' Politecnica delle Marche' University, Via Conca, 60020 Ancona (Italy)

    2008-03-15

    Both pulmonary arterial and peripheral venous sides of venous thromboembolism (VTE) can now be efficiently and safely investigated by multi-detector CT (MDCT) at the same time by a combined CT angiography/CT venography protocol. In the emergency setting, the use of such a single test for patients suspected of suffering from VTE on a clinical grounds may considerably shorten and simplify diagnostic algorithms. The selection of patients to be submitted to MDCT must follow well-established clinical prediction rules in order to avoid generalized referral to CT on a generic clinical suspicion basis and excessive population exposure to increased ionizing radiation dose, especially in young patients. Clinical and anatomical wide-panoramic capabilities of MDCT allow identification of underlying disease that may explain patients' symptoms in a large number of cases in which VTE is not manifest. The analysis of MDCT additional findings on cardiopulmonary status and total thrombus burden can lead to better prognostic stratification of patients and influence therapeutic options. Some controversial points such as optimal examination parameters, clinical significance of subsegmentary emboli, CT pitfalls and/or possible falsely positive diagnoses, and outcome of untreated patients in which VTE has been excluded by MDCT without additional testing, must of course be taken into careful consideration before the definite role of comprehensive MDCT VTE 'one-stop-shop' diagnosis in everyday clinical practice can be ascertained.

  15. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  16. CT diagnostic significance of tuboovarian abscess

    International Nuclear Information System (INIS)

    Du Tieqiao; Dong Jie; Xu Quanying; An Haiqin; Sang Chunyu

    2006-01-01

    Objective: To analyze computed tomographic (CT) imaging features of tuboovarian abscess as well as to discuss CT diagnostic significance. Methods: Ten patients with tuboovarian abscess were performed CT enhancing scans. Results: Ten patients manifested thick-walled, cystic-solid complex adnexal mass and indistinct margins on CT imaging. Internal thick septations and layered enhancement of the mass border on CT contrast images were common. Associated findings of CT included thickening of' the uterosacral ligaments in 9 of 10 patients, increased attenuation of the presacral and perirectal fat secondary to edema in 9 patients, serpiginous structure corresponding to a dilated, pus-filled fallopian tube in 6 patients and fluid-filled within uterine cavity in 4 patients. On CT scans, the inflammatory infiltration of adnexal abscesses involved pelvic structure included adhesion with borders of uterus in 9 patients, adhesion with rectal or sigmoid in 4 patients and pelvic wall or bowel loop in 3 patients. Two cases with peritoneal thicken showed ascites on CT images and right adnexal tuboovarian abscess in 2 patients were associated with appendicitis. Conclusion: CT can reveal pelvic adjacent organs involvement or adhesion and inflammatory infihration of pelvic floor soft-tissues or fascial planes except showing cystic solid complex mass of adnexal location so that indicating characteristics and the extent of the suspected pelvic inflammatory diseases. CT can be valuable in difficult cases of gynecologic infective diseases. (authors)

  17. Correlation of CT perfusion and CT volumetry in patients with Alzheimers disease

    International Nuclear Information System (INIS)

    Czarnecka, A.; Zimny, A.; Sasiadek, M.

    2010-01-01

    Background: Both brain atrophy and decrease of perfusion are observed in dementive diseases. The aim of the study was to correlate the results of brain perfusion CT (pCT) and CT volumetry in patients with Alzheimers disease (AD). Material/Methods: Forty-eight patients with AD (mean age of 71.3 years) underwent brain pCT and CT volumetry. The pCT was performed at the level of basal ganglia after the injection of contrast medium (50 ml, 4 ml/sec.) with serial scanning (delay 7 sec, 50 scans, 1 scan/sec). Volumetric measurements were carried out on the basis of source images, with the use of a dedicated CT software combined with manual outlining of the regions of interest in extracerebral and intraventricular CSF spaces. Perfusion parameters of the cerebral blood flow (CBF) and cerebral blood volume (CBV) from the grey matter of frontal and temporal as well as basal ganglia were compared statistically with the volumetric measurements of frontal and temporal cortical atrophy as well as subcortical atrophy. Results: A statistically significant positive correlation was found between the values of CBF and CBV in the basal ganglia and the volumes of the lateral and third ventricles. The comparison of CBF and CBV results with the volumetric measurements in the areas of the frontal and temporal lobes showed mostly negative correlations, but none of them was of statistical significance. Conclusions: In patients with AD, the degree of cortical atrophy is not correlated with the decrease of perfusion in the grey matter and subcortical atrophy is not correlated with the decrease of perfusion in the basal ganglia region. It suggests that functional and structural changes in AD are not related to each other. (authors)

  18. Third European Company Survey – Direct and indirect employee participation

    NARCIS (Netherlands)

    Akkerman, Agnes; Sluiter, Roderick; Jansen, Giedo

    2015-01-01

    This report studies practices in EU establishments for direct and indirect employee participation in decision-making. Indirect employee participation is the involvement of employee representatives in decision-making processes, while direct employee participation describes direct interaction between

  19. Neutron-capture cross sections from indirect measurements

    Directory of Open Access Journals (Sweden)

    Scielzo N.D.

    2012-02-01

    Full Text Available Cross sections for compound-nuclear reactions reactions play an important role in models of astrophysical environments and simulations of the nuclear fuel cycle. Providing reliable cross section data remains a formidable task, and direct measurements have to be complemented by theoretical predictions and indirect methods. The surrogate nuclear reactions method provides an indirect approach for determining cross sections for reactions on unstable isotopes, which are difficult or impossible to measure otherwise. Current implementations of the method provide useful cross sections for (n,f reactions, but need to be improved upon for applications to capture reactions.

  20. Brain tumor and CT, 1. Relationship between the consistency of a brain tumor and the CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, N.; Katada, K.; Shinomiya, Y.; Sano, H.; Kanno, T. (Fujita Gakuen Univ., School of Medicine, Toyoake, Aichi (Japan))

    1981-08-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively. Twenty-seven cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor.