WorldWideScience

Sample records for incoloy 800h

  1. Tritium Permeability of Incoloy 800H and Inconel 617

    Energy Technology Data Exchange (ETDEWEB)

    Philip Winston; Pattrick Calderoni; Paul Humrickhouse

    2012-07-01

    Design of the Next Generation Nuclear Plant (NGNP) reactor and its high-temperature components requires information regarding the permeation of fission generated tritium and hydrogen product through candidate heat exchanger alloys. Release of fission-generated tritium to the environment and the potential contamination of the helium coolant by permeation of product hydrogen into the coolant system represent safety basis and product contamination issues. Of the three potential candidates for high-temperature components of the NGNP reactor design, only permeability for Incoloy 800H has been well documented. Hydrogen permeability data have been published for Inconel 617, but only in two literature reports and for partial pressures of hydrogen greater than one atmosphere, far higher than anticipated in the NGNP reactor. To support engineering design of the NGNP reactor components, the tritium permeability of Inconel 617 and Incoloy 800H was determined using a measurement system designed and fabricated at Idaho National Laboratory. The tritium permeability of Incoloy 800H and Inconel 617, was measured in the temperature range 650 to 950°C and at primary concentrations of 1.5 to 6 parts per million volume tritium in helium. (partial pressures of 10-6 atm)—three orders of magnitude lower partial pressures than used in the hydrogen permeation testing. The measured tritium permeability of Incoloy 800H and Inconel 617 deviated substantially from the values measured for hydrogen. This may be due to instrument offset, system absorption, presence of competing quantities of hydrogen, surface oxides, or other phenomena. Due to the challenge of determining the chemical composition of a mixture with such a low hydrogen isotope concentration, no categorical explanation of this offset has been developed.

  2. Tritium Permeability of Incoloy 800H and Inconel 617

    Energy Technology Data Exchange (ETDEWEB)

    Philip Winston; Pattrick Calderoni; Paul Humrickhouse

    2011-09-01

    Design of the Next Generation Nuclear Plant (NGNP) reactor and its high-temperature components requires information regarding the permeation of fission generated tritium and hydrogen product through candidate heat exchanger alloys. Release of fission-generated tritium to the environment and the potential contamination of the helium coolant by permeation of product hydrogen into the coolant system represent safety basis and product contamination issues. Of the three potential candidates for high-temperature components of the NGNP reactor design, only permeability for Incoloy 800H has been well documented. Hydrogen permeability data have been published for Inconel 617, but only in two literature reports and for partial pressures of hydrogen greater than one atmosphere, far higher than anticipated in the NGNP reactor. To support engineering design of the NGNP reactor components, the tritium permeability of Inconel 617 and Incoloy 800H was determined using a measurement system designed and fabricated at Idaho National Laboratory. The tritium permeability of Incoloy 800H and Inconel 617, was measured in the temperature range 650 to 950 C and at primary concentrations of 1.5 to 6 parts per million volume tritium in helium. (partial pressures of 10-6 atm) - three orders of magnitude lower partial pressures than used in the hydrogen permeation testing. The measured tritium permeability of Incoloy 800H and Inconel 617 deviated substantially from the values measured for hydrogen. This may be due to instrument offset, system absorption, presence of competing quantities of hydrogen, surface oxides, or other phenomena. Due to the challenge of determining the chemical composition of a mixture with such a low hydrogen isotope concentration, no categorical explanation of this offset has been developed.

  3. Intergranular stresses in Incoloy-800

    International Nuclear Information System (INIS)

    Holden, T.M.; Holt, R.A.; Clarke, A.P.

    1997-01-01

    The generation of intergranular residual strains under uniaxial loading conditions in the plastic regime has been measured in detail by neutron diffraction in Incoloy-800. A relatively simple theory, based on the Taylor model, gives a good semiquantitative account of the magnitudes of the strains. The results clarify the interpretation of measurements made earlier on Incoloy-800 steam generator tubes. (author)

  4. Microstructural characterization of dissimilar welds between Incoloy 800H and 321 Austenitic Stainless Steel

    Energy Technology Data Exchange (ETDEWEB)

    Sayiram, G., E-mail: sayiram.g@vit.ac.in; Arivazhagan, N.

    2015-04-15

    In this work, the microstructural character of dissimilar welds between Incoloy 800H and 321 Stainless Steel has been discussed. The microscopic examination of the base metals, fusion zones and interfaces was characterized using an optical microscope and scanning electron microscopy. The results revealed precipitates of Ti (C, N) in the austenitic matrix along the grain boundaries of the base metals. Migration of grain boundaries in the Inconel 82 weld metal was very extensive when compared to Inconel 617 weldment. Epitaxial growth was observed in the 617 weldment which increases the strength and ductility of the weld metal. Unmixed zone near the fusion line between 321 Stainless Steel and Inconel 82 weld metal was identified. From the results, it has been concluded that Inconel 617 filler metal is a preferable choice for the joint between Incoloy 800H and 321 Stainless Steel. - Highlights: • Failure mechanisms produced by dissimilar welding of Incoloy 800H to AISI 321SS • Influence of filler wire on microstructure properties • Contemplative comparisons of metallurgical aspects of these weldments • Microstructure and chemical studies including metallography, SEM–EDS • EDS-line scan study at interface.

  5. High-temperature corrosion and mechanical properties of protective scales on Incoloy 800H: The influence of preoxidation and ion implantation

    NARCIS (Netherlands)

    Polman, E.A.; Fransen, T.; Gellings, P.J.

    1990-01-01

    Coatings, obtained by preoxidation of Incoloy 800H at low PO2 show good sulphidation resistance due to the higher chromia content in the oxide scale. Yttrium-ion implantation of Incoloy 800H has also a beneficial effect on sulphidation, if preoxidation is applied. The reason for this is presumably

  6. Artificial neural network modeling studies to predict the friction welding process parameters of Incoloy 800H joints

    Directory of Open Access Journals (Sweden)

    K. Anand

    2015-09-01

    Full Text Available The present study focuses on friction welding process parameter optimization using a hybrid technique of ANN and different optimization algorithms. This optimization techniques are not only for the effective process modelling, but also to illustrate the correlation between the input and output responses of the friction welding of Incoloy 800H. In addition the focus is also to obtain optimal strength and hardness of joints with minimum burn off length. ANN based approaches could model this welding process of INCOLOY 800H in both forward and reverse directions efficiently, which are required for the automation of the same. Five different training algorithms were used to train ANN for both forward and reverse mapping and ANN tuned force approach was used for optimization. The paper makes a robust comparison of the performances of the five algorithms employing standard statistical indices. The results showed that GANN with 4-9-3 for forward and 4-7-3 for reverse mapping arrangement could outperform the other four approaches in most of the cases but not in all. Experiments on tensile strength (TS, microhardness (H and burn off length (BOL of the joints were performed with optimised parameter. It is concluded that this ANN model with genetic algorithm may provide good ability to predict the friction welding process parameters to weld Incoloy 800H.

  7. The oxidation behavior of three different zones of welded Incoloy 800H alloy

    International Nuclear Information System (INIS)

    Chen, W.S.; Kai, W.; Tsay, L.W.; Kai, J.J.

    2014-01-01

    Highlights: • The oxidation kinetics of 800H followed the parabolic-rate law in dry-air. • The scales formed on the alloys were composed of Cr 2 O 3 and MCr 2 O 4 (M = Fe, Cr). • Internal-oxidation of Al 2 O 3 and SiO 2 dissolved T i were observed in 800H-SUB and 800H-HAZ • The weight loss behavior of 800H-SUB and 800H-HAZ were observed in wet air. • The mass-loss behavior of 800H-HAZ is more severe than 800H-SUB in wet air. - Abstract: The oxidation behavior of three different zones of welded Incoloy 800H alloys, containing the substrate (800H-SUB), heat-affected zone (800H-HAZ) and the melt zone (800H-MZ) was studied at 950 °C in dry and wet air. The steady-state oxidation rate constants (k p values) were calculated based on the mass-gain data, and the oxidation resistant ability of the alloys followed by the rank of 800H-MZ > 800H-SUB > 800H-HAZ in dry air. The scales formed on the 800H-SUB and 800H-HAZ consisted of a heterophasic mixture of Cr 2 O 3 and FeCr 2 O 4 , while a mixture of Cr 2 O 3 and MnCr 2 O 4 was observed on the 800H-MZ. On the other hand, the oxidation kinetics of the alloy, initially followed the parabolic-rate law up to 48 h, while a significant mass-lost kinetics was observed for a prolong exposure in wet air. The detail oxidation mechanisms for the alloys in both environments were investigated

  8. The microstructure of Incoloy 800 H after long-time creep

    International Nuclear Information System (INIS)

    Sheng Zhongqi; Katerbau, K.

    1993-01-01

    The microstructural change of Incoloy 800 H after creep tests with low loads and long rupture time has been investigated. Cavities nucleate at one side of M 23 C 6 carbide particles on grain boundaries. Microcrack propagate by passing through a string of these cavities, M 23 C 6 carbide particles on grain boundaries have a coherent relationship with one of both neighbouring grains, so grain boundaries are strengthened, and the strengthening effect can be estimated for enhanced activation energy. G phase precipitation can be observed on grain boundaries, but no γ' phase particles can be found. Dislocation substructure is different from the typical recovery creep. Dislocation piles appear near M 23 C 6 carbide particles on grain boundaries. Subgrain structure poorly develop and network distribution of dislocation can remain after relative long creep

  9. Some observations about the Incoloy 800 corrosion

    International Nuclear Information System (INIS)

    Baptista, W.; Sathler, L.; Mattos, O.R.

    1985-01-01

    The chemical and electrochemical characteristics of synthetic solutions similar to those inside the occluded cell corrosion - OCC (pitting, cracks from stress corrosion) of incoloy 800, 25 0 C are studied. (E.G.) [pt

  10. J-integral flaw resistance curves of Incoloy 800H at room temperature

    International Nuclear Information System (INIS)

    Krompholz, K.; Ullrich, G.

    1985-08-01

    J-integral experiments at room temperature were performed on three point bend type specimens of the iron-nickel base alloy Incoloy 800H with a/w-ratios of 0.3 and 0.5. These experiments are performed within the frame of a round robin test in cooperation with German- and US-partners. The tests were performed in stroke control as well as in load control. Three different evaluation procedures were applied: -The signal of the dc potential drop technique -The partial unloading procedure and -The multiple specimen technique. Evaluating the dc potential drop technique and the multiple specimen method delivered reasonable results while the partial unloading procedure failed. The different methods are discussed and fractographic results support these results under discussion. (author)

  11. Pitting of Incoloy 800 in presence of CuII

    International Nuclear Information System (INIS)

    Bianchi, G.L.; Alvarez, M.G.

    1993-01-01

    The pitting behaviour of Incoloy 800 in presence of Cu II ions, at 60 degrees C and 280 degrees C was studied by long term exposition of specimens in aqueous cupric chloride solutions. At 60 degrees C experiments were performed in aerated (7 ppm O 2 ) and deaerated solutions containing 500, 1000, 2000, 10000 and 20000 ppm CuCl 2 . At 280 degrees C experiments were performed in deaerated 20 ppm, 50 ppm and 100 ppm CuCl 2 solutions. During each experiment the open circuit potential of the alloy was measured as a function of time. After corrosion test the specimens were examined by Scanning Electron Microscopy for the presence of pits. In another set of experiments potentiodynamic anodic polarization curves were used to determine the pitting potential of Incoloy 800 in deaerated NaCl solutions at chloride concentrations and pH values corresponding to those possessed by solutions containing 20 ppm to 20000 ppm CuCl 2 . At 60 degrees C pitting was observed in those solutions where the CuCl 2 concentration is higher than 1000 ppm. At 280 degrees C pitting was found in the specimens exposed to those solutions where the CuCl 2 concentration was higher than 20 ppm. (author). 3 refs

  12. Stress corrosion cracking of 316 SS and Incoloy-800 in high temperature aqueous containing sulfate and chloride

    International Nuclear Information System (INIS)

    Zhang Weiguo; Lin Fangliang; Gao Fengqin; Zhou Hongyi; Cao Xiaoning

    1992-03-01

    The stress corrosion cracking (SCC) susceptibility of 316 stainless steel (SS) which was welded for primary pipe and Incoloy-800 (shot peening) for steam generator (SG) tube have been investigated by a slow strain rate test (SSRT) at a strain rate of 4.2 x 10 -6 /s. Tests were conducted at 315 C degree for 316 SS and 270 C degree for In-800 in the oxygenated simulated resin intrusion environment (acidic sulfate). Tests of the effect of combination of SO 4 2- and Cl - on SCC of Incoloy-800 were also carried out. The results indicate that Incoloy-800 is unsusceptible to SCC either in the environment with SO 4 2- (from a few ppm to 1000 ppm, pH 3 ∼ 4) or in the environment of combination of SO 4 2- (1000 ppm) and Cl - (from 2 to 1000 ppm). The 316 NG SS is susceptible to transgranular stress corrosion cracking (TGSCC) in the resin intrusion environment with SO 4 2- in high temperature water

  13. Incoloy 800 anodic behavior in sulfate and chloride solutions at high temperature

    International Nuclear Information System (INIS)

    Lafont, C.; Alvarez, M.G.

    1992-01-01

    The anodic behavior and pitting corrosion resistance of Incoloy 800 in concentrated aqueous chloride and sulphate solutions has been studied by means of electrochemical techniques. The effect of different environmental variables, such as temperature (in the 100 0 C to 280 0 C range) and sulphate ion concentration (0.02 M to 2 M), was evaluated. In another set of experiments, the influence of sulphate ions additions on the pitting resistance and pitting morphology of Incoloy 800 in chloride solutions at high temperature was also examined. (author)

  14. Caustic stress corrosion cracking of Inconel-600, Incoloy-800, and Type 304 stainless steel

    International Nuclear Information System (INIS)

    Theus, G.J.

    1976-01-01

    High-temperature electrochemical tests have resulted in the stress corrosion cracking of Inconel-600 and Incoloy-800 (registered trademarks, International Nickel Company), and Type 304 stainless steel in caustic solutions. Results show that stress corrosion cracking of these alloys can be prevented or accelerated by varying their electrochemical potential. To a certain extent, the same effect can be achieved by altering the gas atmosphere above the test solution from a pure nitrogen cover gas to a mixture of 5 percent H 2 and 95 percent N 2 . The effect of the cover gas can then be negated by adjusting the specimen's electrochemical potential either to cause or to inhibit stress corrosion cracking. Some specifics of the test results reveal that in deoxygenated caustic solutions, Inconel-600 cracks intergranularly at mildly anodic potentials; Incoloy-800 cracks transgranularly at reduced potentials (at or near the open circuit potential) and intergranularly at highly oxidizing potentials; and cracking is mixed (transgranular/intergranular) for Type 304 stainless steel at or near the open circuit potential. The severity of cracking for both Inconel-600 and Incoloy-800 in deoxygenated caustic solutions is reduced by giving the materials a simulated post-weld heat treatment (1150 0 F for 18 h). Test results on Inconel-600 show that high-carbon (0.06 percent) material cracks less severely than low-carbon (0.02 percent) material, in both the simulated post-weld heat-treated condition and the mill-annealed condition

  15. Incoloy 800 stands up to radiation and corrosion in high temperature gas cooled reactors

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Incoloy 800 has been selected for heat exchangers in helium cooled nuclear reactor prototypes for exposure to 350 to 800 0 C helium and high temperature high purity water and steam. 304H stainless steel used in heat exchangers in original design cracked in the superheater area, bellows and tubing after static pressure tests but before exposure to steam. Residual stress, chlorides, and oxygen were deduced to have caused the failures

  16. Properties of protective oxide scales containing cerium on Incoloy 800H in oxidizing and sulfidizing environments. I. Constant-extension-rate study of mechanical properties

    NARCIS (Netherlands)

    Haanappel, V.A.C.; Fransen, T.; Geerdink, Bert; Gellings, P.J.

    1988-01-01

    The mechanical properties of ceramic coatings containing cerium oxide, prepared by the sol-gel method and used to protect Incoloy 800H against aggressive environments, are reported. Deformation and cracking behavior in oxidizing and sulfidizing environments has been investigated by

  17. Effects of PbO on the oxide films of incoloy 800HT in simulated primary circuit of PWR

    International Nuclear Information System (INIS)

    Tan, Yu; Yang, Junhan; Wang, Wanwan; Shi, Rongxue; Liang, Kexin; Zhang, Shenghan

    2016-01-01

    Effects of trace PbO on oxide films of Incoloy 800HT were investigated in simulated primary circuit water chemistry of PWR, also with proper Co addition. The trace PbO addition in high temperature water blocked the protective spinel oxides formation of the oxide films of Incoloy 800HT. XPS results indicated that the lead, added as PbO into the high temperature water, shows not only +2 valance but also +4 and 0 valances in the oxide film of 800HT co-operated with Fe, Cr and Ni to form oxides films. Potentiodynamic polarization results indicated that as PbO concentration increased, the current densities of the less protective oxide films of Incoloy 800HT decreased in a buffer solution tested at room temperature. The capacitance results indicated that the donor densities of oxidation film of Incoloy 800HT decreased as trace PbO addition into the high temperature water. - Highlights: • Trace PbO addition into the high temperature water block the formation of spinel oxides on Incoloy 800HT. • The donor density of oxide film decreases with trace PbO addition. • The current density of potentiodynamic polarization decreases of oxide film with trace PbO addition.

  18. Study of Incoloy 800HT alloy tested by heat-cycling

    International Nuclear Information System (INIS)

    Velciu, L.; Meleg, T.; Pantiru, M.; Petrescu, D.; Voicu, F.

    2016-01-01

    This paper investigated Incoloy 800HT (UNS N08811) alloy after some heat-cycling tests. The study continues prior tests realized in INR Pitesti concerning utilization of some nickel-based alloys in the heat exchangers and steam generators construction. The thermal-cycling consist in a successive series of heating and cooling with some rates in a range temperature. Technical parameters of thermal cycling: 50 & 200 cycles, 25 °C/minute heating-cooling rate, temperature range 450-1000°C, and argon working medium. The analysis consisted in metallographic examination (microstructure), Vickers microhardness, and traction tests. The average grain size was determined by linear interception method (ASTM E-112). The micro hardness was calculated by the relationship of the device technical book. On the Strength-Deformation diagrams were obtained: tensile strength and elongation. The tested samples were compared with the ''as received'' material. The results showed a good metallographic and mechanical behaviour of Incoloy 800HT at these thermal-cycling tests. (authors)

  19. Corrosion of superalloy Incoloy 800H/HT in eutectic mixture LiF-NaF-KF with different addition of chromium fluoride; Korozia superzliatiny Incoloy 800H/HT v eutektickej zmesi LiF-NaF-KF s ruznym pridavkom fluoridu chromiteho

    Energy Technology Data Exchange (ETDEWEB)

    Kontrik, M.; Pavlik, V.; Simko, F. [Slovenska Akademia Vied, Ustav Anorganickej Chemie, Oddelenie Taveninovych Sustav, 84636 Bratislava (Slovakia)

    2013-04-16

    Thesis deals with investigating the addition of chromium trifluoride to eutectic mixture of LiF-NaF-KF (46.5 - 11.5 - 42 mol %) on the corrosion of superalloy Incoloy 800H/HT with static tests. The corrosion losses of the alloy and type of corrosion attack was observed. It was found that the addition of chromium fluoride into the mixture generally increases of corrosion of the material. Several types of corrosion attacks were observed. On the surface of the samples the spotted, pitting and transgranular corrosions were found. On the cross-sections of the samples the subsurface and lamellar corrosions were detected. (authors)

  20. Proposed changes to Incoloy Alloy 800 and 800H specifications

    International Nuclear Information System (INIS)

    Bassford, T.H.; Rahoi, D.W.

    1978-01-01

    Preliminary results from an extensive investigation of Alloy 800 and 800H have led the authors to recommend changes to the specifications covering these alloys usage under Code Case 1592-10 and Sec. VIII, Div. 7. The compositional changes recommended would result in changes in rupture ductility and design stress. (Auth.)

  1. Creep and fatigue properties of Incoloy 800H in a high-temperature gas-cooled reactor (HTGR) helium environment

    International Nuclear Information System (INIS)

    Chow, J.G.Y.; Soo, P.; Epel, L.

    1978-01-01

    A mechanical test program to assess the effects of a simulated HTGR helium environment on the fatigue and creep properties of Incoloy 800H and other primary-circuit metals is described. The emphasis and the objectives of this work are directed toward obtaining information to assess the integrity and safety of an HTGR throughout its service life. The helium test environment selected for study contained 40 μ atm H 2 O, 200 μ atm H 2 , 40 μ atm CO, 10 μ atm CO 2 , and 20 μ atm CH 4 . It is believed that this ''wet'' environment simulates that which could exist in a steam-cycle HTGR containing some leaking steam-generator tubes. A recirculating helium loop operating at about 4 psi in which impurities can be maintained at a constant level, has been constructed to supply the desired environment for fatigue and creep testing

  2. Microstructural characterization and electrochemical corrosion behavior of Incoloy 800 in sulphate and chloride solutions

    International Nuclear Information System (INIS)

    Mansur, Fabio Abud; Schvartzman, Monica Maria de Abreu Mendonca; Campos, Wagner Reis da Costa; Aguiar, Antonio Eugenio de; Chaim, Marcos Souza

    2011-01-01

    Corrosion has been the major cause of tube failures in steam generators (SG) tubes in nuclear power plants. Problems have resulted from impurities in the secondary water systems which are originated from leaks of cooling water. It is important to understand the compatibility of steam generator tube materials with the environment. This study presents the microstructural characterization and electrochemical behavior of the Incoloy 800 in sodium chloride and sodium sulphate aqueous solutions at 80 degree C. Potentiodynamic anodic polarization, cyclic polarization and open circuit potential (OCP) measurements were the electrochemical techniques applied in this work. The pitting resistance of Incoloy 800 in chloride plus sulphate mixtures were also examined. Experiments performed in solutions with different concentrations of Cl- and SO 4 2- ions in solution (200 ppb, 500 ppb, 1ppm, 5 ppm, 50 ppm and 100 ppm) showed that this concentrations range had no substantial effect on the anodic behavior of the alloy. After polarization no localized corrosion was found on the samples. (author)

  3. J-resistance curves for Inconel 690 and Incoloy 800 nuclear steam generators tubes at room temperature and at 300 °C

    Energy Technology Data Exchange (ETDEWEB)

    Bergant, Marcos A., E-mail: marcos.bergant@cab.cnea.gov.ar [Gerencia CAREM, Centro Atómico Bariloche (CNEA), Av. Bustillo 9500, San Carlos de Bariloche 8400 (Argentina); Yawny, Alejandro A., E-mail: yawny@cab.cnea.gov.ar [División Física de Metales, Centro Atómico Bariloche (CNEA) / CONICET, Av. Bustillo 9500, San Carlos de Bariloche 8400 (Argentina); Perez Ipiña, Juan E., E-mail: juan.perezipina@fain.uncoma.edu.ar [Grupo Mecánica de Fractura, Universidad Nacional del Comahue / CONICET, Buenos Aires 1400, Neuquén 8300 (Argentina)

    2017-04-01

    The structural integrity of steam generator tubes is a relevant issue concerning nuclear plant safety. In the present work, J-resistance curves of Inconel 690 and Incoloy 800 nuclear steam generator tubes with circumferential and longitudinal through wall cracks were obtained at room temperature and 300 °C using recently developed non-standard specimens' geometries. It was found that Incoloy 800 tubes exhibited higher J-resistance curves than Inconel 690 for both crack orientations. For both materials, circumferential cracks resulted into higher fracture resistance than longitudinal cracks, indicating a certain degree of texture anisotropy introduced by the tube fabrication process. From a practical point of view, temperature effects have found to be negligible in all cases. The results obtained in the present work provide a general framework for further application to structural integrity assessments of cracked tubes in a variety of nuclear steam generator designs. - Highlights: •Non-standard fracture specimens were obtained from nuclear steam generator tubes. •Specimens with circumferential and longitudinal through-wall cracks were used. •Inconel 690 and Incoloy 800 steam generator tubes were tested at 24 and 300 °C. •Fracture toughness for circumferential cracks was higher than for longitudinal cracks. •Incoloy 800 showed higher fracture toughness than Inconel 690 steam generator tubes.

  4. Effect of lead on Inconel 600 and Incoloy 800 oxide layers formed in simulated steam generator secondary environments

    International Nuclear Information System (INIS)

    Garcia-Mazario, M.; Lancha, A.M.; Hernandez, M.; Maffiotte, C.

    1996-01-01

    The existence of lead in steam generators, detected during the analysis of deposits in the damaged areas of tubing, supports the hypothesis that lead may contribute to the cracking problems experienced in steam generator tubes. In addition, the harmful effect of lead on Inconel 600 is known not only through laboratory tests but also as a result of operating experience. Operating experience of Incoloy 800 is, however, much more limited and there are very few laboratory studies in this area. Taking into account that thin films formed on metals reflect the interaction between such metals and the aqueous environment and also that incoloy 800 is considered to be a suitable material for new steam generators as a substitute for Inconel 600, attempts to determine the effect of lead on corrosion films are considered useful with a view to better understanding the stress-corrosion-cracking behaviour of these materials. For these reasons the objective of this paper is to gain some insights into the effect of lead on the oxide layers forming on Inconel 600 and Incoloy 800 tested in the laboratory in various aggressive lead-containing environments. Auger electron spectroscopy (AES) and electron spectroscopy for chemical analysis (ESCA) have been used to study the composition of these oxide layers. (orig.)

  5. Electro chemical studies on stress corrosion cracking of Incoloy-800 in caustic solution, part I: As received samples

    Directory of Open Access Journals (Sweden)

    Dinu Alice

    2005-01-01

    Full Text Available Many non-volatile impurities accidentally introduced into the steam generator tend to Concentrate on its surface in restricted flow areas. In this way these impurities can lead to stress corrosion cracking (SCC on stressed tubes of the steam generator. Such impurities can be strong alkaline or acid solutions. To evaluate the effect of alkaline concentrated environments on SCC of steam generator tubes, the tests were con ducted on stressed samples of Incoloy-800 in 10% NaOH solution. To accelerate the SCC process, stressed specimens were anodically polarised in a caustic solution in an electro chemical cell. The method of stressing of Incoloy-800 tubes used in our experiments was the C-ring. Using the cathodic zone of the potentiodynamic curves it was possible to calculate the most important electrochemical parameters: the corrosion current, the corrosion rate, and the polarization resistance. We found that the value of the corrosion potential to initiate the SCC microcracks was -100 mV. The tested samples were examined using the metallographic method. The main experimental results showed that the in crease of the stress state promoted the in crease of the SCC susceptibility of Incoloy-800 samples tested under the same conditions, and that the length of the SCC-type microcracks in creased with the growth of the stress value.

  6. Surface analytical and electrochemical characterization of oxide films formed on Incoloy-800 and carbon steel in simulated secondary water chemistry conditions of PHWRs

    International Nuclear Information System (INIS)

    Rangarajan, S.; Sinu, C.; Balaji, V.; Narasimhan, S.V.

    2010-01-01

    The water chemistry in the Steam Generator (SG) Circuits of Indian Pressurized Heavy Water Reactors (PHWRs) is controlled by the all volatile treatment (AVT) procedure, wherein volatile amines are used to maintain the alkaline pH required for minimizing the corrosion of the structural materials. Earlier, Monel and morpholine were used as the Steam Generator material and the alkalizing agent respectively. However, currently they are replaced by Incoloy-800 and Ethanolamine (ETA). ETA was chosen because of its beneficial effects due to low pK b and K d values, loading behaviour on condensate polishing unit (CPU) and also on cost comparison with other amines. Since we have Incoloy-800 on the tube side and Carbon steel(CS) on the shell side in the SG circuits, efforts were taken to study the nature of the oxide films formed on these surfaces and to evaluate the corrosion resistance and electrochemical properties of the same, under simulated secondary water chemistry conditions of PHWRs containing different dissolved oxygen (DO) concentration. In this context, experiments were carried out by exposing finely polished CS and Incoloy -800 coupons to ETA based medium in the presence and absence of Hydrazine (pH: 9.2) at 240 o C under two different DO conditions (< 10 ppb and 200 ppb) for 24 hours. Oxide films formed under these conditions were characterized using SEM, Raman spectroscopy, electrochemical impedance, polarization and Mott-Schottky techniques. Further, studies at a controlled DO level ( < 10 ppb) were carried out for different time durations viz., 7- and 30- days. The composition, surface morphology, oxide thickness, resistance, type of semi-conductivity and defect density of the oxide films were evaluated and correlated with the DO levels and discussed elaborately in this paper. (author)

  7. Electrochemical and surface characterisation of oxide films on nano-grain nickel films electrodeposited on INCOLOY-800

    International Nuclear Information System (INIS)

    Navin Vinayak, S.; Sunitha, Y.; Rangarajan, S.; Narasimhan, S.V.

    2008-01-01

    Nano materials have different properties from the corresponding bulk materials because of fine grain size, large fraction of surface atoms, high surface energy and high grain boundary volume fraction. For similar reasons, the nano-alloy coatings show superior high-temperature corrosion resistance and are generally more resistant to stress corrosion cracking. Hence, it is of interest to know the materials performance, if the structural materials used in nuclear reactors are made of nano-grains. In Indian PHWRs, Incoloy-800 is being used as the steam generator tubing material. It's corrosion resistance property is very important as it forms not only the pressure boundary between the radioactive primary water and non-active secondary water but also from the view point of loss of heavy water, in case of any corrosion damage. In this paper, the corrosion resistance of the oxide films formed on nano-grain nickel film electrodeposited on Incoloy-800 (a) in the presence of saccharine (WS) and (b) in the absence of saccharine (WOS) were compared with that formed on Commercial Ni foil, using electrochemical dc polarization and ac impedance techniques. The surface morphology, elemental analysis and grain size were studied with SEM, EDX and XRD techniques respectively. The nano-grain nickel films were prepared on Incoloy-800 by electrodeposition using Watt's Bath with saccharine sodium as a surfactant. The oxide films were developed by exposing them to LiOH solution (pH-10.0) at 245 deg C for 3 days (A-group) and 7 days (B-group). XRD results showed that the grain size of Ni formed in the absence of saccharine (WOS) was ∼ 60 nm and did not change after being autoclaved. But, for Ni formed in the presence of saccharine (WS), the grain size was ∼ 16 nm which increased to 40-50 nm after being autoclaved. With both A and B-group specimens, the PDAP curves showed an active-passive transition, a passive region and a transpassive region in 2N H 2 SO 4 . However, the critical

  8. On the significance of a subsequent ageing after cold working of Incoloy 800 at operational temperatures

    International Nuclear Information System (INIS)

    Ullrich, G.; Krompholz, K.

    1993-01-01

    The influence of cold working and subsequent ageing at operational temperatures on the long-term and short-term mechanical properties of components made from the iron-nickel-chromium base alloy Incoloy 800 are discussed. Long-term properties are time-to-rupture strengths, which are included in the design code, over a lifetime of 300,000 hours. For LWR operating temperatures of 350 o C, this is of minor importance. An operating temperature of 550 o C is possible for Incoloy 800 with up to 25% cold working and a subsequent solution annealing at 950 o C, without loss of time-to-rupture strength compared with the 'as received' state. The short-term mechanical properties are strongly influenced by cold working, in the form of increasing yield strength and rupture strength, and decreasing ductility and consequently loss in impact energies. A subsequent ageing at 550 o C leads to a decrease of the yield strength and rupture strength, and an increase of ductility as well as the impact energies. The environmental influence are discussed. (author) 3 figs., 1 tab., 8 refs

  9. Resistance of Incoloy 800 steam generator tube to pitting corrosion in PWR secondary water at 250°C

    International Nuclear Information System (INIS)

    Schvartzman, Mônica M.A.M.; Albuquerque, Adriana Silva de; Esteves, Luiza; Rabello, Emerson G.; Mansur, Fábio Abud

    2017-01-01

    The steam generator (SG) is one of the main components of a PWR, so the performance of this type of nuclear power plant depends to a large extent on the trouble-free operation of SGs. Its degradation significantly affects the overall plant performance. Alloy 800NG (Incoloy® 800) is a nickel-iron-chromium alloy used for steam generator tubes in PWRs due to their high strength, good workability and resistance to corrosion. This behavior is attributed to the protective oxide film formed on the metal surface by contact with the high temperature pressurized water. However, chloride is one of major SG impurities that cause the breakdown of the passive film and initiate localized corrosion in passive metals as Alloy 800NG. The aim of this study is to provide information about the pitting corrosion behavior of the Incoloy® 800 steam generator tube under normal secondary circuit parameters (250 deg C and 5 MPa) and abnormal conditions of operation (presence of chloride ions in the secondary water). For this, optical microscopy, XRD and EDS analysis and electrochemical tests have been carried out under simulated PWR secondary water operating conditions. The susceptibility to pitting corrosion was evaluated using electrochemical tests and the oxide layer formed on material was examined by means of scanning electron microscopy (SEM) and energy dispersive X-ray spectrometer (EDS) analyses. (author)

  10. Resistance of Incoloy 800 steam generator tube to pitting corrosion in PWR secondary water at 250°C

    Energy Technology Data Exchange (ETDEWEB)

    Schvartzman, Mônica M.A.M. [Pontifícia Universidade Católica de Minas Gerais (PUC-Minas), Belo Horizonte, MG (Brazil); Albuquerque, Adriana Silva de; Esteves, Luiza; Rabello, Emerson G.; Mansur, Fábio Abud, E-mail: monicacdtn@gmail.com, E-mail: asa@cdtn.br, E-mail: luiza.esteves@cdtn.br, E-mail: egr@cdtn.br, E-mail: fametalurgica@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    The steam generator (SG) is one of the main components of a PWR, so the performance of this type of nuclear power plant depends to a large extent on the trouble-free operation of SGs. Its degradation significantly affects the overall plant performance. Alloy 800NG (Incoloy® 800) is a nickel-iron-chromium alloy used for steam generator tubes in PWRs due to their high strength, good workability and resistance to corrosion. This behavior is attributed to the protective oxide film formed on the metal surface by contact with the high temperature pressurized water. However, chloride is one of major SG impurities that cause the breakdown of the passive film and initiate localized corrosion in passive metals as Alloy 800NG. The aim of this study is to provide information about the pitting corrosion behavior of the Incoloy® 800 steam generator tube under normal secondary circuit parameters (250 deg C and 5 MPa) and abnormal conditions of operation (presence of chloride ions in the secondary water). For this, optical microscopy, XRD and EDS analysis and electrochemical tests have been carried out under simulated PWR secondary water operating conditions. The susceptibility to pitting corrosion was evaluated using electrochemical tests and the oxide layer formed on material was examined by means of scanning electron microscopy (SEM) and energy dispersive X-ray spectrometer (EDS) analyses. (author)

  11. Study of the polarization for Incoloy 800 and for the stainless stell AISI 304 in mixtures of Iron, Nickel and Chromium Chlorides

    International Nuclear Information System (INIS)

    Travalloni, A.M.; Sathler, L.; Mattos, O.R.

    1985-01-01

    Polarization curves for the Incoloy 800 and for the stainless stell AISI 304 were obtained with static and rotational electrodes. The electrolytes employed showed growing concentrations of mixtures as Iron, Nickel and Chromium Chlorides their proportion being the same as the content of these elements in the respective alloys. The alloys under investigation exhibited a continuous transition behaviour from the passive to the active-passive and to the active conditions. Also, the pH was found the main parameter controlling the anodic behaviour of the alloy. (Author) [pt

  12. Multi-response optimization of process parameters for TIG welding of Incoloy 800HT by Taguchi grey relational analysis

    Directory of Open Access Journals (Sweden)

    Arun Kumar Srirangan

    2016-06-01

    Full Text Available Incoloy 800HT which was selected as one of the prominent material for fourth generation power plant can exhibit appreciable strength, good resistance to corrosion and oxidation in high temperature environment. This study focuses on the multi-objective optimization using grey relational analysis for Incoloy 800HT welded with tungsten inert arc welding process with N82 filler wire of diameter 1.2 mm. The welding input parameters play a vital role in determining desired weld quality. The experiments were conducted according to L9 orthogonal array. The input parameter chosen were the welding current, Voltage and welding speed. The output response for quality targets chosen were the ultimate tensile strength and yield strength (at room temperature, 750 °C and impact toughness. Grey relational analysis was applied to optimize the input parameters simultaneously considering multiple output variables. The optimal parameters combination was determined as A2B1C2 i.e. welding current at 110 A, voltage at 10 V and welding speed at 1.5 mm/s. ANOVA method was used to assess the significance of factors on the overall quality of the weldment. The output of the mechanical properties for best and least grey relational grade was validated by the metallurgical characteristics:

  13. Analysis of incoloy 800ht alloy tested in thermal transient conditions

    International Nuclear Information System (INIS)

    Velciu, L.; Meleg, T.; Nitu, A.; Popa, L.

    2015-01-01

    This paper investigated Incoloy 800 HT alloy after following thermal transient tests: fast heating rates (50° and 90°C/minute) up to 1,000°C, maintaining this temperature level (0 and 60 minutes), furnace-cooling until 220°C, and then air-cooling. This alloy is one of the candidate materials for construction of the steam generators of the future NPP reactors. The analysis consisted in metallographic examination and traction tests. The samples were investigated using the Olympus GX 71 optical microscope, the OPL microdurometer with automatic cycle and WALTER BAI traction device. The average grain size was determined by linear interception method. The micro hardness was calculated by the relationship from the device technical book. On the traction diagrams were obtained: strength resistance (Rm), elongation at rupture (A) and elastic modulus (E). The tested alloy was compared with the ''as received'' material, and the results showed a good behavior of this alloy in the presented conditions. (authors)

  14. Why incoloy 800 was selected as tube material for the new steam generators of Doel 3

    International Nuclear Information System (INIS)

    Stubbe, J.; Wolters, F.; Somville, P.; De Ranter, K.

    1990-01-01

    Incoloy 800 or Inconel 690. This was the basic question for the SG of DOEL 3, to be replaced in 1993. A comparative evaluation was made, focused on the service behaviour, more particularly the corrosion resistance. It was concluded that both materials may be considered for SG replacement. They are indeed substantially superior to alloy 600, but none of them is really better than the other one: - they are both nearly completely immune to primary water stress corrosion cracking; - they are both susceptible to some types of attack from the secondary side. To the 690 credit are the globally better performances in the secondary side corrosion tests. However if the aggressive environments which are unlikely to occur at DOEL 3 are discarded, it appears that the margin between 690 and 800 is small. To the 800 credit is the favourable service experience except the secondary side wastage due to phosphate conditioning. 800 was finally selected not only because of favourable economic arguments, but also because of the important weight attributed to the service behaviour by the Belgian Utilities [fr

  15. The effect of borate and phosphate inhibitors on corrosion rate material SS321 and incoloy 800 in chloride containing solution by using potentiodynamic method

    International Nuclear Information System (INIS)

    Febriyanto; Sriyono; Satmoko, Ari

    1998-01-01

    Determination of corrosion rate of steam generator materials (SS 321 and incoloy 800) in chloride containing solution using potentiodynamic method from CMS 100. NaCl 1%, 3% and 5% solution using is used as tested solution. A tested material is grounded by grinding paper on grade 400 600, 800 and 1000, then polished by METADI 1/4 microns paste to get homogeneity. Furthermore, the tested materials is mounted by epoxide resin, so only the surface which contacts to tested solution is open. From the result obtained that borate and phosphate inhibitor can reduce corrosion rate and aggressiveness of chloride ion

  16. Electrochemical studies on stress corrosion cracking of incoloy-800 in caustic solution. Part II: Precracking samples

    Directory of Open Access Journals (Sweden)

    Dinu Alice

    2006-01-01

    Full Text Available Stress corrosion cracking (SCC in a caustic medium may affect the secondary circuit tubing of a CANDU NPP cooled with river water, due to an accidental formation of a concentrated alkaline environment in the areas with restricted circulation, as a result of a leakage of cooling water from the condenser. To evaluate the susceptibility of Incoloy-800 (used to manufacture steam generator tubes for CANDU NPP to SCC, some accelerated corrosion tests were conducted in an alkaline solution (10% NaOH, pH = 13. These experiments were performed at ambient temperature and 85 °C. We used the potentiodynamic method and the potentiostatic method, simultaneously monitoring the variation of the open circuit potential during a time period (E corr/time curve. The C-ring method was used to stress the samples. In order to create stress concentrations, mechanical precracks with a depth of 100 or 250 μm were made on the outer side of the C-rings. Experimental results showed that the stressed samples were more susceptible to SCC than the unstressed samples whereas the increase in temperature and crack depth lead to an increase in SCC susceptibility. Incipient micro cracks of a depth of 30 μm were detected in the area of the highest peak of the mechanical precrack.

  17. Effects of Heat Input on the Mechanical and Metallurgical Characteristics of Tig Welded Incoloy 800Ht Joints

    Directory of Open Access Journals (Sweden)

    Kumar S. Arun

    2017-09-01

    Full Text Available This study focuses on the effect of heat input on the quality characteristics of tungsten inert arc gas welded incoloy 800HT joints using inconel-82 filler wire. Butt welding was done on specimens with four different heat inputs by varying the process parameters like welding current and speed. The result indicated that higher heat input levels has led to the formation of coarser grain structure, reduced mechanical properties and sensitization issues on the weldments. The formation of titanium nitrides provided resistance to fracture and increased the tensile strength of the joints at high temperatures. Further aging was done on the welded sample at a temperature of 750°C for 500 hours and the metallographic result showed formation of carbides along the grain boundaries in a chain of discrete and globular form which increased the hardness of the material. The formation of spinel NiCr2O4 provided oxidation resistance to the material during elevated temperature service.

  18. Temperature dependence of the dynamic fracture toughness of the alloy Incoloy 800 after cold work

    International Nuclear Information System (INIS)

    Krompholz, K.; Ullrich, G.

    1991-02-01

    Precracked charpy-V-notch specimens of the iron-nickel base alloy Incoloy 800 in the as-received condition and after cold work have been tested using an instrumented impact tester (hammer) in the temperature range 293 ≤ T/K ≤ 1223. The specific impact energies were determined by dial readings, from the integration of the load versus time and the load versus load point displacement diagrams; in all cases the agreement was excellent. The specific impact energies and the impulses are correlated with the test temperature and with the degree of cold work, respectively. The dynamic fracture toughness values were determined following the equivalent energy approach. In all cases a distinct decrease of the mechanical properties in the range between the as-received state and after 5 % cold work was found. The temperature behaviour of the impact energies clearly reveals an increase of its value between room temperature and 673 K. This increase is distinctly reduced after cold work. The dynamic fracture toughness decreases with increasing temperature. The fracture surfaces clearly show elasto-plastic fracture behaviour of the material in the temperature regime investigated. (author) 19 figs., 3 tabs., 7 refs

  19. Experimental research regarding the corrosion of incoloy-800 and SA 508 cl.2 in the CANDU steam generator

    International Nuclear Information System (INIS)

    Lucan, D.; Fulger, M.; Savu, G.; Velciu, L.

    2004-01-01

    Steam generators (SGs) are crucial components of pressurized water reactors. The failure of the steam generator as a result of tube degradation by corrosion has been a major cause of Pressurized Water Reactor (PWR) plant unavailability. Steam generator problems have caused major economic losses in terms of lost electricity production through forced unit outages and, in cases of extreme damage, as additional direct cost for large-scale repair or replacement of steam generators. Steam generator tubes are susceptible to failure by a variety of mechanisms, the vast majority of which are related a corrosion. The feedwater that enters into the steam generators under normal operating conditions is extremely pure, but nevertheless contains low levels (generally in the μg/l concentration range) of impurities such as iron, chloride, sulphate, silicate, etc. When water is converted to steam and exits the steam generator, the non-volatile impurities are left behind. As a result, their concentration in the bulk steam generator water is considerably higher than those in the feedwater. Nevertheless, the concentrations of corrosive impurities are still generally sufficiently low that the bulk water is not significantly aggressive towards steam generator materials. The excellent performance to date of CANDU steam generators can be attributed, in part, to their design and performance characteristics, which typically involve higher recirculation ratios and lower heat fluxes and temperatures. The purpose of this paper consists in assessment of generalized corrosion behaviour of the tubes materials (Incoloy-800) and tubesheet material (carbon steel SA 508 cl.2) at the normal secondary circuit parameters (temperature-260 deg C, pressure-5.1MPa). The testing environment was the demineralized water without impurities, at pH=9.5 regulated with morpholine and ciclohexilamine (all volatile treatment - AVT). The results are presented like micrographies and graphics representing loss of metal

  20. Residual stresses determination in an 8 mm Incoloy 800H weld via neutron diffraction

    International Nuclear Information System (INIS)

    Chen, Xizhang; Zhang, Shu Yan; Wang, Jingjun; Kelleher, Joe F.

    2015-01-01

    Highlights: • Stress through thickness at 5 mm from weld centerline indicates a “U” distribution. • Declining of tensile stress through thickness occurred at weld centerline. • Residual stress between layers is the lowest. - Abstract: To investigate the distribution of residual stresses, the 8 mm 800H alloy was joined by multi-layer butt TIG process. Residual stresses in the longitudinal, transverse and normal directions were measured via neutron diffraction. These residual stress measurements were taken at a series of points 2 mm below the top surface, covering the fusion zone, heat affected zone (HAZ) and base metal. In addition, two lines of longitudinal residual stress values at the weld centerline and 5 mm from weld centerline through thickness were measured. Results show that both the longitudinal and transverse stresses from the weld centerline to base metal are mainly tensile stresses. The longitudinal residual stress is the largest, with a maximum value of 330 MPa. As for the normal residual stress, the weld zone shows tensile stress, while the HAZ shows compressive stress. The middle of the thickness shows compressive residual stress along the thickness direction. The longitudinal stress at weld centerline through thickness reveals the interlayer heat treat effects leads to a declining of tensile stress. While the stress at 5 mm from weld centerline indicates a “U” distribution due to the mixed microstructure close to fusion line. With the increasing distance from weld seam, the residual stress decreases gradually

  1. Creep and low cycles fatigue behaviour of inconel 617 and alloy 800H in the temperature range 1073-1223

    International Nuclear Information System (INIS)

    Yun, H.M.

    1984-01-01

    The creep rupture properties of high temperature alloys are being determined as part of the materials programme for the development of the high temperature, gas-cooled reactor (HTGR) as a source of nuclear process heat, especially for the gasification of lignite and coal. INCOLOY 800H AND INCONEL 617 have been tested in the temperature range from 1073 K to 1223 K in air as well as in helium with HTGR specific impurities. The static and dynamic creep behaviour of INCONEL 617 have been determined in constant load creep tests, relaxation tests and stress reduction tests. The results have been interpreted using the internal stress on the applied stress and test temperature was determined. In a few experiments the influence of cold deformation prior to the creep test on the magnitude of the internal stress was also investigated. (Author)

  2. Corrosion Characterization in Nickel Plated 110 ksi Low Alloy Steel and Incoloy 925: An Experimental Case Study

    Science.gov (United States)

    Thomas, Kiran; Vincent, S.; Barbadikar, Dipika; Kumar, Shresh; Anwar, Rebin; Fernandes, Nevil

    2018-04-01

    Incoloy 925 is an age hardenable Nickel-Iron-Chromium alloy with the addition of Molybdenum, Copper, Titanium and Aluminium used in many applications in oil and gas industry. Nickel alloys are preferred mostly in corrosive environments where there is high concentration of H2S, CO2, chlorides and free Sulphur as sufficient nickel content provides protection against chloride-ion stress-corrosion cracking. But unfortunately, Nickel alloys are very expensive. Plating an alloy steel part with nickel would cost much lesser than a part make of nickel alloy for large quantities. A brief study will be carried out to compare the performance of nickel plated alloy steel with that of an Incoloy 925 part by conducting corrosion tests. Tests will be carried out using different coating thicknesses of Nickel on low alloy steel in 0.1 M NaCl solution and results will be verified. From the test results we can confirm that Nickel plated low alloy steel is found to exhibit fairly good corrosion in comparison with Incoloy 925 and thus can be an excellent candidate to replace Incoloy materials.

  3. Nickel-plating for active metal dissolution resistance in molten fluoride salts

    Energy Technology Data Exchange (ETDEWEB)

    Olson, Luke [Department of Engineering Physics, 1500 Engineering Drive, University of Wisconsin, Madison, WI 53706 (United States); Sridharan, Kumar, E-mail: kumar@engr.wisc.edu [Department of Engineering Physics, 1500 Engineering Drive, University of Wisconsin, Madison, WI 53706 (United States); Anderson, Mark; Allen, Todd [Department of Engineering Physics, 1500 Engineering Drive, University of Wisconsin, Madison, WI 53706 (United States)

    2011-04-15

    Ni electroplating of Incoloy-800H was investigated with the goal of mitigating Cr dissolution from this alloy into molten 46.5%LiF-11.5%NaF-42%KF eutectic salt, commonly referred to as FLiNaK. Tests were conducted in graphite crucibles at a molten salt temperature of 850 deg. C. The crucible material graphite accelerates the corrosion process due to the large activity difference between the graphite and the alloy. For the purposes of providing a baseline for this study, un-plated Incoloy-800H and a nearly pure Ni-alloy, Ni-201 were also tested. Results indicate that Ni-plating has the potential to significantly improve the corrosion resistance of Incoloy-800H in molten fluoride salts. Diffusion of Cr from the alloy through the Ni-plating does occur and if the Ni-plating is thin enough this Cr eventually dissolves into the molten salt. The post-corrosion test microstructure of the Ni-plating, particularly void formation was also observed to depend on the plating thickness. Diffusion anneals in a helium environment of Ni-plated Incoloy-800H and an Fe-Ni-Cr model alloy were also investigated to understand Cr diffusion through the Ni-plating. Further enhancements in the efficacy of the Ni-plating as a protective barrier against Cr dissolution from the alloy into molten fluoride salts can be achieved by thermally forming a Cr{sub 2}O{sub 3} barrier film on the surface of the alloy prior to Ni electroplating.

  4. Compatibility of heat resistant alloys with boron carbide, 5

    International Nuclear Information System (INIS)

    Baba, Shinichi; Kurasawa, Toshimasa; Endow, Taichi; Someya, Hiroyuki; Tanaka, Isao.

    1986-08-01

    This paper includes an experimental result of out-of-pile compatibility and capsule design for irradiation test in Japan Materials Testing Reactor (JMTR). The compatibility between sheath material and neutron absorber materials for control rod devices (CRD) was examined for potential use in a very high temperature reactor (VHTR) which is under development at JAERI. The purpose of the compatibility tests are preliminary evaluation of safety prior to irradiation tests. Preliminary compatibility evaluation was concerned with three items as follows : 1) Lithium effects on the penetrating reaction of Incoloy 800H alloy in contact with a mixture of boronated graphite and lithium hydroxide powders, 2) Short term tensile properties of Incoloy 800H and Hastelloy XR alloy reacted with boronated graphite and fracture mode analysis, 3) Reaction behavior of both alloys under transient power conditions of a VHTR. It was clear that the reaction rate constant of the Incoloy 800H alloy was accelerated by doping lithium hydroxide into the boron carbide and graphite powder. The mechanical properties of Incoloy 800H and Hastelloy XR alloy reacted with boronated graphite were decreased. Ultimate tensile strength and tensile ductilities at temperatures over 850 deg C were reduced, but there was no change in the proof (yield) stress. Both alloys exhibited a brittle intergranular fracture mode during transient power conditions of a VHTR and also exhibited severe penetration. Irradiation capsules for compatibility test were designed to simulate three irradiation conditions of VHTR: 1) steady state for VHTR, 2) Transient power condition, 3) Service limited life of CRD. Capsule irradiation experiments have been carried out satisfactorily and thus confirm the validity of the capsule design procedure. (author)

  5. Effect of a helium environment on the mechanical properties of HTGR primary system metals

    International Nuclear Information System (INIS)

    Chow, J.G.Y.; Soo, P.; Sabatini, R.L.

    1978-01-01

    Creep and high cycle fatigue tests have been carried out on Incoloy 800H and Hastelloy X in a helium environment containing 40 μ atm of H 2 O, 200 μ atm H 2 , 40 μ atm CO, 20 μ atm CH 4 and 10 μ atm CO 2 . The creep behavior of Incoloy 800H does not appear to show significant differences from that measured in air. However, the Hastelloy X at the maximum test temperature studied (871 0 C, 1600 0 F) shows behavior which is inferior. With respect to high cycle fatigue, the Incoloy 800H is weaker in the helium environment at a test temperature of 649 0 C (1200 0 F). At 760 0 C (1400 0 F) the strength in helium is higher but there is a tendency to lose strength more rapidly than for the air tests as the test time increases. Hastelloy X tested at 871 0 C (1600 0 F) also shows higher strength in helium for short test times but for extended tests the strengths in air and helium become similar. Scanning electron microprobe analyses have been carried out to correlate the strength measurements with surface oxidation characteristics and internal structural changes

  6. Multiaxial creep of tubes from Incoloy 800 H and Inconel 617 under static and cyclic loading conditions

    International Nuclear Information System (INIS)

    Penkalla, H.J.; Nickel, H.; Schubert, F.

    1989-01-01

    At temperatures above 800 0 C the material behaviour under mechanical load is determined by creep. The service of heat exchanging components leads to multiaxial loading conditions. For design and inelastic analysis of the component behaviour time dependent design values and suitable constitutive equations are necessary. The present report gives a survey of the approaches to describing creep under multiaxial loading. Norton's law and v. Mises' theory are applied. The load combinations of internal pressure, tensile and torsional stress are studied more closely, cyclic stress superposition in the tensile-pulsating range is discussed and cases of partial relaxation are examined. Experimental results are presented for the loading conditions discussed, and satisfactory agreement between theory and experiment has been found up to now for these results. Regarding lifetime determination under multiaxial creep load, a more precise analysis of creep damage is presented suggesting a suitable deviatoric stress for evaluation in the long-time range. (orig.)

  7. Development of high temperature property database for Alloy 800H

    International Nuclear Information System (INIS)

    Yokoyama, Norio; Watanabe, Katsutoshi; Tsuji, Hirokazu; Nakajima, Hajime.

    1993-07-01

    JAERI Material Performance Database (JMPD) has been developed since 1989 in JAERI with a view to utilizing the various kinds of characteristic data of nuclear materials efficiently. Using relational database management system, PLANNER on the mainframe, the JMPD provides the retrieval supporting system, graphic and statistical analyses system. The data obtained with 7868 sets on characteristic data of metallic materials including fatigue crack growth data, etc. have been stored in the JMPD at the end of March in 1993. A ferritic superalloy, Alloy 800H is used for the structural material of the control rods of the High Temperature Engineering Test Reactor (HTTR). Thermal stress generates which might cause a severe creep damage at a reactor scram. It therefore needs to be designed with consideration on the fracture modes induced by creep deformation after neutron irradiation. The creep data (approximately 240 sets) and tensile data (approximately 100 sets) of Alloy 800H including the effects of test environment, aging treatment and neutron irradiation have been stored in the JMPD. Furthermore, using a personal computer, high temperature property database for Alloy 800H has been developed. The present report outlines the development of high temperature property database for Alloy 800H. (author)

  8. On the influence of cold work on the oxidation behavior of some austenitic stainless steels: High temperature oxidation

    NARCIS (Netherlands)

    Langevoort, J.C.; Fransen, T.; Gellings, P.J.

    1984-01-01

    AISI 304, 314, 321, and Incoloy 800H have been subjected to several pretreatments: polishing, milling, grinding, and cold drawing. In the temperature range 800–1400 K, cold work improves the oxidation resistance of AISI 304 and 321 slightly, but has a relatively small negative effect on the

  9. Use of ferritic steels in breeder reactors worldwide

    International Nuclear Information System (INIS)

    Patriarca, P.

    1983-01-01

    The performance of LMFBR reactor steam generator materials is reviewed. Tensile properties of stainless steel-304, stainless steel-316, chromium-molybdenum steels, and Incoloy 800H are presented for elevated temperatures

  10. Long range plan for flexible joint development program

    International Nuclear Information System (INIS)

    Objective is to develop bellows expansion joints into CDS and subsequent LMFBR and liquid metal applications. An assessment was performed on the use of Incoloy 800H and Inconel 718 as bellows materials

  11. Effects of HTGR helium on the high cycle fatigue of structural materials

    International Nuclear Information System (INIS)

    Soo, P.; Sabatini, R.L.; Gerlach, L.

    1982-01-01

    High cycle fatigue tests have been conducted on Incoloy 800H and Hastelloy X in air and in HTGR helium environments containing low and high levels of moisture. For the helium environments, a higher mositure level usually gives a lower fatigue strength. For air, however, the strength is usually much lower than those for helium. For long test times at higher test temperatures, the fatigue strengths for Incoloy 800H often show a large decrease, and the fatigue limits are much lower than those anticipated from low cycle tests. Optical and scanning electron microscope observations were made to correlate fatigue life with surface and bulk microstructural changes in the material during test. Oxide scale cracking and spallation, surface recrystallization and intergranular attack appear to contribute to losses in fatigue strength

  12. Weldability and mechanical property characterization of weld clad alloy 800H tubesheet forging

    International Nuclear Information System (INIS)

    King, J.F.; McCoy, H.E.

    1984-09-01

    The weldability of an alloy 800H forging that simulates a steam generator tubesheet is studied. Weldability was of concern because a wide range of microstructures was present in this forging. The top and portions of the bottom were weld clad with ERNiC-3 weld metal to a thickness of 19 mm similar to that anticipated for HTGR steam generators. Examinations of the clad fusion line in various regions revealed no weldability problems except possibly on the bottom portion, which contained large grains and some as-cast structure. A few microfissures were evident in this region, but no excessive hot cracking tendency was observed. The tensile properties in all areas of the clad forging were reasonable and not influenced greatly by the microstructure. The elevated-temperature tests showed strong tendency for fracture in the heat-affected zone of the alloy 800H. Creep failure at 649 0 C consistently occurred in the heat-affected zone of the alloy 800H, but the creep strength exceeded the expected values for alloy 800H

  13. Creep properties of heat-resistant superalloys for nuclear plants in helium

    International Nuclear Information System (INIS)

    Shimizu, Shigeki; Satoh, Keisuke; Matsuda, Shozo; Murase, Hirokazu; Fujioka, Junzo.

    1979-01-01

    In order to estimate the creep and rupture strengths of candidate alloys for the intermediate heat exchanger of VHTR, creep and stress rupture tests in impure helium were conducted on Hastelloy X, Inconel 617, Inconel 625, Incoloy 800 and Incoloy 807 at 900 0 C. The results were discussed in comparison with those in air and the alloys were examined from the point of view of the elevated temperature structural design. The main results obtained are summarized as follows: (1) No appreciable decrease in creep and rupture strengths in helium as compared with those in air is observed on Hastelloy X and Inconel 625. On the contrary, the creep and rupture strengths of Inconel 617 in helium decrease slightly as compared with those in air. In the case of Incoloy 807, the creep strength to cause 1 percent total strain and that to initiate secondary creep increase remarkably in helium as compared with those in air. However, the creep strength to cause initiation of tertiary creep and the rupture strength in helium remarkably decrease as compared with those in air. (2) The order of magnitude of the S 0 value for each material in helium is as follows; Hastelloy X > Inconel 617 > Incoloy 807 > Inconel 625 > Incoloy 800 Meanwhile, that of the S sub(t) value in helium is; Inconel 617 > Hastelloy X > Incoloy 807 > Inconel 625 > Incoloy 800. (author)

  14. Tangential turning of Incoloy alloy 925 using abrasive water jet technology

    Czech Academy of Sciences Publication Activity Database

    Cárach, J.; Hloch, S.; Hlaváček, Petr; Ščučka, Jiří; Martinec, Petr; Petrů, J.; Zlámal, T.; Zeleňák, Michal; Monka, P.

    -, 11 July 2015 (2015), s. 1-6 ISSN 0268-3768 R&D Projects: GA MŠk ED2.1.00/03.0082; GA MŠk(CZ) LO1406 Institutional support: RVO:68145535 Keywords : incoloy alloy 925 * abrasivewater jet turning * traverse speed * surface roughness Subject RIV: JQ - Machines ; Tools Impact factor: 1.568, year: 2015 http://link.springer.com/article/10.1007/s00170-015-7489-0

  15. Tangential turning of Incoloy alloy 925 using abrasive water jet technology

    Czech Academy of Sciences Publication Activity Database

    Cárach, J.; Hloch, S.; Hlaváček, Petr; Ščučka, Jiří; Martinec, Petr; Petrů, J.; Zlámal, T.; Zeleňák, Michal; Monka, P.; Lehocká, D.; Krolczyk, J.

    2016-01-01

    Roč. 82, č. 9 (2016), s. 1747-1752 ISSN 0268-3768 R&D Projects: GA MŠk ED2.1.00/03.0082; GA MŠk(CZ) LO1406 Institutional support: RVO:68145535 Keywords : incoloy alloy 925 * abrasive water jet turning * traverse speed Subject RIV: JQ - Machines ; Tools Impact factor: 2.209, year: 2016 http://link.springer.com/article/10.1007%2Fs00170-015-7489-0

  16. Creep crack growth verification testing in alloy 800H tubular components

    International Nuclear Information System (INIS)

    Hunter, C.P.; Hurst, R.C.

    1992-01-01

    A method for determining the creep crack growth, CCG, and stress rupture behaviour of Alloy 800H tubular components containing longitudinal notches at 800deg C is described. The presence of the notch is found to systematically weaken the tube, the degree of weaking dependent upon the notch length and depth. The creep crack growth rates, determined from a specially adapted potential drop technique are compared with those obtained from conventional compact tension type specimens. Using the stress intensity factor, K 1 , and the C * parameter as the basis of comparison it is found that the latter gives excellent correlation between the specimen and component behaviour. Finally attention is drawn to the potential dangers of predicting the component creep crack growth behaviour from the data obtained using conventional specimens for a structure sensitive material such as Alloy 800H and conversely to the advantages of the component type CCG tests developed in the present work. (orig.)

  17. The crystallography of fatigue crack initiation in Incoloy-908 and A-286 steel

    International Nuclear Information System (INIS)

    Krenn, C.R.

    1996-12-01

    Fatigue crack initiation in the austenitic Fe-Ni superalloys Incoloy-908 and A-286 is examined using local crystallographic orientation measurements. Results are consistent with sharp transgranular initiation and propagation occurring almost exclusively on {111} planes in Incoloy-908 but on a variety of low index planes in A-286. This difference is attributed to the influence of the semicoherent grain boundary η phase in A-286. Initiation in each alloy occurred both intergranularly and transgranularly and was often associated with blocky surface oxide and carbide inclusions. Taylor factor and resolved shear stress and strain crack initiation hypotheses were tested, but despite an inconclusive suggestion of a minimum required {111} shear stress, none of the hypotheses were found to convincingly describe preferred initiation sites, even within the subsets of transgranular cracks apparently free from the influence of surface inclusions. Subsurface inclusions are thought to play a significant role in crack initiation. These materials have applications for use in structural conduit for high field superconducting magnets designed for fusion energy use

  18. Relaxation and corrosion resistance of alloy 800 used for steam generator tubes of ship borne boilers

    International Nuclear Information System (INIS)

    Corrieu, J.M.; Cortial, F.; Maillard, J.L.; Vernot-Loier, C.; Lebeau, M.

    1994-01-01

    The INCO ''INCOLOY 800'' trademark groups the Fe-Cr-Ni alloys containing 30 to 35% nickel, 19 to 23% chromium, 0,15 to 0,60% aluminium, 0,15 to 0,60% titanium and less than 0,10% carbon contents, used as construction materials for condenser and heat exchanger tubes. In parallel with water chemistry control and studies aimed at reducing the residual stresses resulting from tube expansion, studies have been conducted to a better understanding of this alloy, its metallurgy and its corrosion behaviour under accurately defined fabrication and heat treatment conditions. The purpose of this paper is to present the results of a behaviour study of INDRET alloy 800 concerning isothermal relaxation and effects of the said relaxation heat treatments on alloy microstructure studied with a transmission electron-chemical method to determine the sensitiveness to intergranular corrosion, and by electrochemistry in pressurized hot water. (authors). 4 figs., 5 tabs., 7 refs

  19. Correlation between microstructure and the creep behaviour at high temperature of Alloy 800 H

    International Nuclear Information System (INIS)

    Spiradek, K.; Degischer, H.P.; Lahodny, H.

    1989-01-01

    A systematic metallographic study was performed to identify the nature of the microstructural changes occurring during high temperature creep deformation of Alloy 800 H. Creep tests were carried out at 800 deg. C under constant load conditions corresponding to the initial stresses between 25 and 80 MPa. Some tests were interrupted after certain elongations to provide the samples for electron microscopy. Emphasis was put on the creep periods relevant to design where only a few per cent of deformation are tolerable. The influence of the initial material conditions on the creep behaviour was examined. Variations of the initial microstructures were achieved by different solution treatments (980/1250) deg. C, preageing at 800 deg. C (0/6400) h and cold deformation up to 10% followed by ageing at 800 deg. C. The results of the microstructural examinations were correlated with the creep curves that provide a basis for identification of the creep mechanisms operating at the test conditions. (author). 14 refs, 17 figs

  20. Corrosion of Inconel-625, Hastelloy-X280 and Incoloy-800 in 550 - 750°C superheated steam. Influence of alloy heat treatment, surface treatment, steam temperature and steam velocity. Part I: Results up to 6000 hours exposure time. RCN Report

    International Nuclear Information System (INIS)

    Tilborg, P.J. van; Linde, A. van der

    1969-10-01

    Sheet samples of Inconel-625, Hastelloy-X280 and Incoloy-800 were tested, in the solution annealed and in the solution annealed + 20% cold worked + 800°C tempered condition, in steam with a velocity of 5 m/sec. at 550, 650 and 750°C and in steam with a volocity of 15 and 85 m/sec. at 550°C. At 550°C and 750°C the samples were tested in the heat treated, annealed or tempered and the heat treated + electropolished condition. At 650°C moreover as heat treated + ground and pickled samples were tested. Post-corrosion sample investigations involved measurement of the adherent oxide thickness, the total amount of corroded metal, the metal loss to system, and the metallographic and microprobe investigation of the adherent oxide film and adjacent diffusion disturbed alloy layer. The results obtained up to 6000 hours exposure time showed that the surface treatment has a decisive influence on the corrosion behaviour of all three alloys tested. The differences in the corrosion data for the two heat treatment conditions are small. The influence of the steam velocity, as tested at 550°C, on the initial corrosion rate was surprisingly high, while the long-term linear corrosion rates are only slightly influenced by the gas velocity. In general the linear corrosion rates were low, 1-5 mg/dm 2 month, and not consistently affected by the test-temperature. The metal loss to system values were 2 <15 mg/dm 2 in the low velocity steam at all three test temperatures and <30 mg/dm 2 in the high velocity steam at 550°C. The metallographic and microprobe examinations revealed no remarkable results, as compared with the results of analogous tests reported in literature. (author)

  1. Protection of stainless-steels against corrosion in sulphidizing environments by Ce oxide coatings: X-ray absorption and thermogravimetric studies

    NARCIS (Netherlands)

    Fransen, T.; Gellings, P.J.; Fuggle, J.C.; van der Laan, G.; Esteva, J.-M.; Karnatak, R.C.

    1985-01-01

    In this paper a study is reported concerning ceramic coatings containing cerium oxide, prepared by the sol-gel method, used to protect Incoloy 800H against sulphidation. When the coating is sintered in air at 850°C good protection is obtained. In an X-ray absorption spectroscopic study of the

  2. On the grain boundary character distribution of Incoloy 800H during dynamic recrystallization

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Yu, E-mail: vieri32825@126.com [College of Materials Science and Engineering, Chongqing University, Chongqing 400045 (China); Di, Hongshuang [State Key Laboratory of Rolling and Automation, Northeastern University, Shenyang 110819 (China); Huang, Guangjie [College of Materials Science and Engineering, Chongqing University, Chongqing 400045 (China)

    2017-04-01

    In this paper, we investigated the influence of hot deformation parameters on the distribution and proliferation of twin boundaries during dynamic recrystallization (DRX). The results showed that microstructure evolution is characterized by a process of “dynamic recovery (DRV)→necklace/multiple necklace→fully DRX” with increasing temperature and decreasing strain rate. The predominant proliferation mechanism of Σ3{sup n} (1 ≤ n ≤ 3) boundaries is transformed from Σ3 regeneration to new twinning during the growth of DRX grains.

  3. On the grain boundary character distribution of Incoloy 800H during dynamic recrystallization

    International Nuclear Information System (INIS)

    Cao, Yu; Di, Hongshuang; Huang, Guangjie

    2017-01-01

    In this paper, we investigated the influence of hot deformation parameters on the distribution and proliferation of twin boundaries during dynamic recrystallization (DRX). The results showed that microstructure evolution is characterized by a process of “dynamic recovery (DRV)→necklace/multiple necklace→fully DRX” with increasing temperature and decreasing strain rate. The predominant proliferation mechanism of Σ3 n (1 ≤ n ≤ 3) boundaries is transformed from Σ3 regeneration to new twinning during the growth of DRX grains.

  4. General Corrosion studies of a Titanium and Incoloy based alloys under ammoniacal medium and at 290 deg. C

    International Nuclear Information System (INIS)

    Gokhale, B.K.; Keny, S.J.; Kumbhar, A.G.; Rangarajan, S.; Bera, S.; Nuwad Jitendra; Kumar, Sanjukta A.; Wagh, D. N.; Pradhan, S.

    2012-09-01

    For their use in future PWR applications, the general corrosion behaviors of two modified alloys of titanium and Incoloy were studied at high temperature and high pressure (290 deg. C, 7400 Kpa) under ammoniated atmosphere and compared. Coupons were exposed to solutions of varying ammonia concentrations of (10, 50 and 100 ppm ) at 290 deg. C under non-deaerated conditions in a static autoclave for 20 days. Surface characteristics of exposed coupons were studied using XRF, SEM, EDAX and XPS. The solution in the autoclave was analyzed for its specific conductivity, pH and for the elemental concentrations leached from alloy. The exposed titanium based alloy showed deposition of white crystalline material (300-1000 nm size) on the surface. Depletion of Ti and increase in the oxygen concentration on the exposed surface was observed. This indicated dissolution of Ti in solution from surface at high temperature and pressure and its reaction with oxygen in solution to form oxide and its redeposition on surface. The oxide film compositions were found to change drastically between 10 and 50 ppm ammoniated solution. Ti was found to be enriched in the oxide film when the solution contained 50 ppm of ammonia whereas the opposite effect was observed at 10 ppm of ammonia. The presence Ti 4+ in oxide environment and traces of Cr 3+ were observed but no nitrogen or Zr was detected. Specific conductivity of the exposed solution was found to increase by 30 μS/cm and pH to decrease by 1.5 units. Slight leaching of Ti was observed in solution. No Zr was found in the leached solution. Presence of other elements like Al, Cr, Ni in the exposed solution indicated leaching of autoclave construction material (hastelloy). This alloy showed good resistance for corrosion under the experimental conditions. The exposed surface of Incoloy based alloy showed Ni, Cr, Cu and Mn on the surface with deposition of crystalline particles (200-300 nm size). The exposed surface also showed a decrease in Cr

  5. Modell experiments to determine the effect of inhibitive oxide layers on metals against hydrogen permeation

    International Nuclear Information System (INIS)

    Zink, U.

    1983-11-01

    The coupling of H 2 -permeation and corrosion has been examined with the high-temperature alloys Incoloy 800 and Incoloy 802. Permeationsrates as well as corrosionsrates have been measured simultanously under H 2 O-H 2 atmospheres in the test-facility HD-PERM. Test parameters have been temperature and oxidationpotential. Parabolic laws for the growth of the oxide scales have been identified and are considered to be highly important for the efficiency of a permeation barrier. A comparison between the temperature dependencies of corrosionsrates and H 2 -permeationsrates has revealed that permeation and corrosion are coupled only in so far that the permeation barrier is formed by the corrosion reaction. The corrosion data (parabolic rate constant, activation energy) of the oxide scales have given clear indications for the existence of a Cr 2 O 3 -layer, which is considered to be responsible for efficient oxide permeation barriers. (orig.) [de

  6. A Review of Alloy 800H for Applications in the Gen IV Nuclear Energy Systems

    International Nuclear Information System (INIS)

    Ren, Weiju; Swindeman, Robert W.

    2010-01-01

    Alloy 800H is currently under consideration for applications in the Next Generation Nuclear Plant at operational temperatures above 750 C. To provide supporting information in this paper at the attempt to facilitate the consideration, service requirements of the nuclear system for structural materials is first described; and then an extensive review of Alloy 800H is given on its codification with respect to development and research history, mechanical behavior and design allowables, metallurgical aging resistance, environmental effect considerations, data requirements and availability, weldments, as well as many other aspects relevant to the intended nuclear application; an finally further research and development activities to support the materials qualification are suggested.

  7. The tensile properties of alloys 800H and 617 in the range 20 to 950deg C

    International Nuclear Information System (INIS)

    Abd El-Azim, M.E.; Ennis, P.J.; Schuster, H.; Nickel, H.

    1990-01-01

    The tensile properties of Alloy 800H and Alloy 617 in the solution treated condition and after ageing or carburization have been determined for the temperature range 20 to 950deg C. It was found that ageing at 900deg C prior to testing led to an increase in strength and a decrease in ductility at test temperatures up to 700deg C. Above 700deg C, there was no significant difference between the tensile properties of solution treated and aged material. Carburization caused a severe loss of ductility in both alloys at temperatures of 20 to around 800deg C, but the ductility increased sharply at test temperatures above 800deg C, accompanied by a change in the fracture mode from fracture of the carbide particles themselves to void formation and separation at the carbide/matrix interface. The correlation between tensile properties and creep data was investigated in tests carried out at different strain rates. Reasonable agreement was found at 800 to 950deg C for Alloy 617 and at 800 to 900deg C for Alloy 800H. Strain ageing effects were observed in both alloys at some temperatures and strain rates; these effects were serrated flow, negative strain rate sensitivity, peaks in the normalized UTS-temperature curves and plateaus in the elongation-temperature curves. The experimental results were interpreted in the light of two current models for strain ageing, the dislocation-dislocation interaction model and the dislocation-solute interaction model. (orig.) [de

  8. Total photoabsorption cross sections for {sup 1}H, {sup 2}H and {sup 3}He from 200 to 800 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Mac Cormick, M.; Audit, G. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Astrophysique, de la Physique des Particules, de la Physique Nucleaire et de l`Instrumentation Associee; Altieri, S.; Braghieri, A. [Istituto Nazionale di Fisica Nucleare, Pavia (Italy)]|[Pavia Univ. (Italy). Ist. di Fisica Nucleare; Ahrens, J.; Beck, R. [Mainz Univ. (Germany). Inst. fuer Kernphysik; Annand, J.R.M.; Crawford, R.A. [Glasgow Univ. (United Kingdom). Dept. of Physics and Astronomy; Dolbilkin, B.; Zabrodin, A. [AN SSSR, Moscow (Russian Federation). Inst. Yadernykh Issledovanij] [and others

    1996-01-01

    The total photoabsorption cross sections for {sup 1}H, {sup 2}H and {sup 3}He have been measured for incident photon energies ranging from 200 to 800 MeV. The results show clearly the changes in the nucleon resonances in going from {sup 1}H to {sup 3}He. In particular, for the D{sub 13} region the behaviour for {sup 3}He is intermediate between that for {sup 1}H, {sup 2}H and heavier nuclei. (author). Submitted to Physical Review, C (US); 26 refs.

  9. Creep properties of superalloys for the HTGR in impure helium environments

    International Nuclear Information System (INIS)

    Kawakami, H.; Nakanishi, T.

    1981-01-01

    This paper describes creep behaviors of two heat resistant alloys, Hastelloy X and Incoloy 800, in helium environments of the HTGR. In impure helium environments, these alloys are susceptible to carburization and oxidization. We have investigated these effects separately, and related them to the creep behaviors of the alloys. Experiments were carried out at 900 0 C both in helium and in air. Carburization results in decrease of secondary creep strain rate and delay of tertiary creep initiation. Oxidization caused decrease in tertiary creep strain rate of Hastelloy X, but did not that of Incoloy 800. Enhancement in tertiary creep strain rate of Hastelloy X in a very weakly oxidizing environment was confirmed in creep crack growth experiment using notched plate specimens. The rupture time of Hastelloy X in helium was short when compared with in air. Stress versus rupture time curves for both environments were parallel up to 5000 hours test, and a ratio of rupture stress in helium to that in air was about 0.9. In case of Incoloy 800, rupture time in helium was markedly prolonged as compared with that in air. (orig.)

  10. Testing of degradation of alloy 800 H in impure helium at 760 °C

    Czech Academy of Sciences Publication Activity Database

    Berka, J.; Vilémová, Monika; Sajdl, P.

    2015-01-01

    Roč. 464, September (2015), s. 221-229 ISSN 0022-3115 Institutional support: RVO:61389021 Keywords : High temperature corrosion * impure helium * 800 H * Generation IV nuclear reactors Subject RIV: JF - Nuclear Energetics OBOR OECD: Nuclear related engineering Impact factor: 2.199, year: 2015 http://www.sciencedirect.com/science/article/pii/S0022311515002019#

  11. Characterization of high temperature tensile and creep–fatigue properties of Alloy 800H for intermediate heat exchanger components of (V)HTRs

    Energy Technology Data Exchange (ETDEWEB)

    Kolluri, M., E-mail: kolluri@nrg.eu; Pierick, P. ten, E-mail: tenpierick@nrg.eu; Bakker, T., E-mail: t.bakker@nrg.eu

    2015-04-01

    Highlights: • High temperature tensile, creep–fatigue (C–F) properties of Alloy 800H are studied. • Strength and uniform elongation properties at 800 °C are much lower than RT values. • Strong influence of hold time and Δε{sub tot} on low cycle fatigue life was observed. • The total allowable C–F damage (D) at 800 °C decreases with the decreasing Δε{sub tot}. • Synergetic effect of C–F interactions showed stronger effect at lower Δε{sub tot} values. - Abstract: Alloy 800H is considered as a candidate material for intermediate heat exchanger (IHX) components of (very) high temperature reactors (V)HTRs. Qualification of the this alloy for the aforementioned nuclear applications requires understanding of its high temperature tensile, low-cycle fatigue behavior and creep–fatigue interactions because the IHX components suffer from combined creep–fatigue loadings resulting from thermally induced strain cycles associated with start-up and shutdown cycles. To this end, in this paper, the tensile properties of the Alloy 800H base and tungsten inert gas (TIG) welded materials are studied at three different temperatures, room temperature 21, 700 and 800 °C. Low cycle fatigue (LCF) behavior of the base material is investigated at 800 °C with no-hold time (no-HT) and hold time (HT) to study creep–fatigue interactions. The tensile test results showed substantial differences between the strength and ductility properties of the base and weld materials at all 3 temperatures, however, the trends in temperature dependence of tensile properties are similar for both base and weld materials. LCF studies with no-HT and HT showed a strong influence of HT on the low cycle fatigue life of this alloy illustrating the substantial influence of creep mechanisms at 800 °C. Finally, cumulative values of creep versus fatigue damage fractions are plotted in a creep–fatigue interaction diagram and these results are discussed with respect to the existing bi

  12. Creep properties of heat-resistant superalloys for nuclear plants in helium

    International Nuclear Information System (INIS)

    Shimizu, Shigeki; Satoh, Keisuke; Honda, Yoshio; Matsuda, Shozo; Murase, Hirokazu

    1979-01-01

    Creep properties of candidate superalloys for VHTR components in a helium environment at both temperatures of 800 0 C and 900 0 C were compared with those of the same alloys in the atmospheric condition, and the superalloys were contrasted with each other from the viewpoint of high temperature structural design. At 800 0 C, no significant effect of a helium environment on creep properties of the superalloys is observed. At 900 0 C, however, creep strength of Inconel 617, Incoloy 800 and Incoloy 807 in the helium environment decrease more than in the atmospheric environment. In Hastelloy X and Inconel 625, there is no significant difference between creep strengths in helium and those in the atmospheric condition. Concerning So and St values in helium at 900 0 C, Inconel 617 and Hastelloy X are clearly superior to other superalloys. (author)

  13. Corrosion of heat exchanger materials under heat transfer conditions

    International Nuclear Information System (INIS)

    Tapping, R.L.; Lavoie, P.A.; Disney, D.J.

    1987-01-01

    Severe pitting has occurred in moderator heat exchangers tubed with Incoloy-800 in Pickering Nuclear Generating Station. The pitting originated on the cooling side (outside) of the tubes and perforation occurred in less than two years. It was known from corrosion testing at CRNL that Incoloy-800 was not susceptible to pitting in Lake Ontario water under isothermal conditions. Corrosion testing with heat transfer across the tube wall was carried out, and it was noted that severe pitting could occur under deposits formed on the tubes in silty Lake Ontario water. Subsequent testing, carried out in co-operation with Ontario Hydro Research Division, investigated the pitting resistance of other candidate tubing alloys: Incoloy-825, 904 L stainless steel, AL-6X, Inconel-625, 70:30 Cu:Ni, titanium, Sanicro-30 and Sanicro-28 1 . Of these, only titanium and Sanicro-28 have not suffered some degree of pitting attack in silt-containing Lake Ontario Water. In the absence of silt, and hence deposits, no pitting took place on any of the alloys tested

  14. Some factors influencing the creep behaviour of alloy 800

    International Nuclear Information System (INIS)

    Asbury, F.E.; Willoughby, G.

    1975-01-01

    Studies have been made of the stability of the creep behaviour of two commercial casts of Incoloy 800, one high carbon and the other low carbon. The effects of pre-ageing, of prolonged creep up to 10 4 hours duration, and of grain size were investigated. Three factors were found to excercise a major influence on creep behaviour. Firstly, when the high carbon alloy was heat treated at 1150degC super-saturation effects, ascribed principally to carbon, gave some initial strengthening which would not, however, persist for the duration of service life in nuclear power plant applications above 600degC. Secondly, a gamma-dash type phase precipitated readily at 550 to 600degC, giving a marked increase in creep strength. Nucleation was sluggish at higher temperatures but once established, this form of strengthening could persist up to at least 650degC. Creep under non-isothermal conditions at 600 to 700degC would be complex on account of the behaviour of this phase. The hardening associated with its precipitation was greater in the low carbon alloy. Finally it was demonstrated that, in spite of gamma-dash precipitation, fine grained low carbon material was weak in creep at low stresses and temperatures. This was ascribed to the occurrence of grain boundary diffusion creep. It appears that this source of weakening would persist in service, and severely restrict the maximum temperature of usage for fined grained high tensile material. (author)

  15. V S30, slope, H 800 and f 0: performance of various site-condition proxies in reducing ground-motion aleatory variability and predicting nonlinear site response

    Science.gov (United States)

    Derras, Boumédiène; Bard, Pierre-Yves; Cotton, Fabrice

    2017-09-01

    The aim of this paper is to investigate the ability of various site-condition proxies (SCPs) to reduce ground-motion aleatory variability and evaluate how SCPs capture nonlinearity site effects. The SCPs used here are time-averaged shear-wave velocity in the top 30 m ( V S30), the topographical slope (slope), the fundamental resonance frequency ( f 0) and the depth beyond which V s exceeds 800 m/s ( H 800). We considered first the performance of each SCP taken alone and then the combined performance of the 6 SCP pairs [ V S30- f 0], [ V S30- H 800], [ f 0-slope], [ H 800-slope], [ V S30-slope] and [ f 0- H 800]. This analysis is performed using a neural network approach including a random effect applied on a KiK-net subset for derivation of ground-motion prediction equations setting the relationship between various ground-motion parameters such as peak ground acceleration, peak ground velocity and pseudo-spectral acceleration PSA ( T), and M w, R JB, focal depth and SCPs. While the choice of SCP is found to have almost no impact on the median ground-motion prediction, it does impact the level of aleatory uncertainty. V S30 is found to perform the best of single proxies at short periods ( T < 0.6 s), while f 0 and H 800 perform better at longer periods; considering SCP pairs leads to significant improvements, with particular emphasis on [ V S30- H 800] and [ f 0-slope] pairs. The results also indicate significant nonlinearity on the site terms for soft sites and that the most relevant loading parameter for characterising nonlinear site response is the "stiff" spectral ordinate at the considered period.[Figure not available: see fulltext.

  16. Optimizing the Diffusion Welding Process for Alloy 800H: Thermodynamic, Diffusion Modeling, and Experimental Work

    International Nuclear Information System (INIS)

    Mizia, R.E.; Clark, D.E.; Glazoff, M.V.; Lister, Tedd E.; Trowbridge, T.L.

    2011-01-01

    A research effort was made to evaluate the usefulness of modern thermodynamic and diffusion computational tools, Thermo-Calc(copyright) and Dictra(copyright), in optimizing the parameters for diffusion welding of Alloy 800H. This would achieve a substantial reduction in the overall number of experiments required to achieve optimal welding and post-weld heat treatment conditions. This problem is important because diffusion welded components of Alloy 800H are being evaluated for use in assembling compact, micro-channel heat exchangers that are being proposed in the design of a high temperature gas-cooled reactor by the US Department of Energy. The modeling was done in close contact with experimental work. The latter included using the Gleeble 3500 System(reg sign) for welding simulation, mechanical property measurement, and light optical and Scanning Electron Microscopy. The modeling efforts suggested a temperature of 1150 C for 1 hour with an applied pressure of 5 MPa using a 15 μm Ni foil as a joint filler to reduce chromium oxidation on the welded surfaces. Good agreement between modeled and experimentally determined concentration gradients was achieved, and model refinements to account for the complexity of actual alloy materials are suggested.

  17. Synodic periods of asteroids 333, 402, 481, and 800

    Science.gov (United States)

    Denchev, P.; Shkodrov, V.; Ivanova, V.

    2000-08-01

    The asteroids 333 Badenia, 402 Chloe, 481 Emita and 800 Kressmannia have been observed using photoelectric photometry during their 1997 apparations. The obtained synodic periods are: 333 Badenia - 9.96 h; 402 Chloe - 7.111 h; 481 Emita - 14.35 h and 800 Kressmannia - 4.457 h. There are no published periods so far for the first three. We obtained the phase parameters of 402 Chloe, they are H=8.86 and G=0.11.

  18. Creep rupture behavior of candidate materials for nuclear process heat applications

    International Nuclear Information System (INIS)

    Schubert, F.; te Heesen, E.; Bruch, U.; Cook, R.; Diehl, H.; Ennis, P.J.; Jakobeit, W.; Penkalla, H.J.; Ullrich, G.

    1984-01-01

    Creep and stress rupture properties are determined for the candidate materials to be used in hightemperature gas-cooled reactor (HTGR) components. The materials and test methods are briefly described based on experimental results of test durations of about20000 h. The medium creep strengths of the alloys Inconel-617, Hastelloy-X, Nimonic-86, Hastelloy-S, Manaurite-36X, IN-519, and Incoloy-800H are compared showing that Inconel-617 has the best creep rupture properties in the temperature range above 800 0 C. The rupture time of welded joints is in the lower range of the scatterband of the parent metal. The properties determined in different simulated HTGR atmospheres are within the scatterband of the properties obtained in air. Extrapolation methods are discussed and a modified minimum commitment method is favored

  19. Creep crack growth investigations for elevated temperature material application

    International Nuclear Information System (INIS)

    Krompholz, K.; Pierick, J.B.; Grosser, E.D.

    1981-01-01

    Creep crack growth data for the cast alloys IN-519 at 1123 K, Manaurite 36 X at 1123 K and 1173 K, and for the wrought alloys Incoloy 800 H and Inconel 617 at 1123 K, 1173 K, 1223 K, and 1273 K are reported. Up to 1273 K the crack lengths were measured by means of the potential drop technique. The data are plotted da/dt vs. net section stress. These results are compared with data on Inconel 617 analyzed according to stress intensity. (orig.)

  20. The properties of protective oxide scales containing cerium on alloy 800H in oxidizing and oxidizing/sulphidizing environments

    NARCIS (Netherlands)

    Haanappel, V.A.C.; Haanappel, V.A.C.; Fransen, T.; Geerdink, Bert; Gellings, P.J.; Stroosnijder, M.F.

    1991-01-01

    The corrosion protection of oxide scales formed by electrophoretic deposition in a cerium-containing sol on Alloy 800H, a 32Ni-20Cr steel, followed by firing in air at 1123 K was studied in oxidizing and mixed oxidizing/sulphidizing environments at elevated temperatures. In particular, the influence

  1. Influence of S, P, C on grain boundary diffusion and creep properties of Alloy 800; Einfluss von S, P, C auf die Korngrenzendiffusion und Kriecheigenschaften von Alloy 800

    Energy Technology Data Exchange (ETDEWEB)

    Lindemann, J.; Hannesen, K.; Mast, R.; Viefhaus, H. [Max-Planck-Institut fuer Eisenforschung GmbH, Duesseldorf (Germany); Grabke, H.J.

    1998-12-31

    The paper reports examinations of Alloy 800 and specific commercially available variants known under the names of 800H, 800HT, and 800LC, differing in their concentrations of C, Al, and Ti. In addition, melts also containing phosphorus (0.09 wt-%) or sulfur (0.04 wt-%) as additional alloying materials have been prepared for the experiments. The volume diffusion and the grain boundary diffusion of {sup 59}Fe in those alloys was measured at temperatures between 800 and 1000 C by means of a radioactive tracer method combined with residual activity measurements. It was found that accompanying elements like phosphorus and sulfur increase the activation energy of the grain boundary diffusion of the iron and thus delay the grain boundary self-diffusion in Alloy 800. Creep curves were measured of the same materials after age-hardening treatment for 100 hours at 800 C, measurements performed at constant temperature but at three different, constant creep stress loads. The results showed that addition of phosphorus markedly increases the lifetime of Alloy 800, and reduces the creep rupture strain. The minimum strain rate in Alloy 800 containing 0.09 wt-% of phosphorus was found to be lower by a factor of 100, as compared to the other Alloy 800 materials used. (orig./CB) [Deutsch] Alloy 800 ist ein austenitischer Fe-Ni-Cr Stahl, der relativ geringe, aber wichtige Konzentrationen von Kohlenstoff, Aluminium und Titan enthaelt. Besondere Varianten von Alloy 800, bekannt als 800H, 800HT und 800LC, unterscheiden sich in den Konzentrationen dieser Elemente. Diese kommerziellen Legierungen wurden untersucht, und zusaetzlich wurden Schmelzen mit zulegiertem Phosphor (0,09 Gew-%) bzw. Schwefel (0,04 Gew-%) hergestellt. Mittels einer radioaktiven Tracermethode in Verbindung mit Restaktivitaetsmessungen wurde die Volumen- und Korngrenzendiffusion von {sup 59}Fe in diesen Legierungen im Temperaturbereich 800-1000 C gemessen. Es wurde gefunden, dass Begleitelemente wie Phosphor und

  2. A comparative study of the corrosion resistance of incoloy MA 956 and PM 2000 superalloys

    Directory of Open Access Journals (Sweden)

    Maysa Terada

    2010-12-01

    Full Text Available Austenitic stainless steels, titanium and cobalt alloys are widely used as biomaterials. However, new medical devices require innovative materials with specific properties, depending on their application. The magnetic properties are among the properties of interest for some biomedical applications. However, due to the interaction of magnetic materials with Magnetic Resonance Image equipments they might used only as not fixed implants or for medical devices. The ferromagnetic superalloys, Incoloy MA 956 and PM 2000, produced by mechanical alloying, have similar chemical composition, high corrosion resistance and are used in high temperature applications. In this study, the corrosion resistance of these two ferritic superalloys was compared in a phosphate buffer solution. The electrochemical results showed that both superalloys are passive in this solution and the PM 2000 present a more protective passive film on it associated to higher impedances than the MA 956.

  3. Relationship between carburization and zero-applied-stress creep dilation in Alloy 800H and Hastelloy X

    International Nuclear Information System (INIS)

    Inouye, H.; Rittenhouse, P.L.

    1981-01-01

    Typical HTGR candidate alloys can carburize when exposed to simulated service environments. The carbon concentration gradients so formed give rise to internal stresses which could cause dilation. Studies performed with Hastelloy X and Alloy 800H showed that dilations of up to almost 1% can occur at 1000 0 C when carbon pickup is high. Dilation was normally observed only when the carbon increase was >1000 μg/cm 2 and ceased when diffusing carbon reached the center of the specimen. (Auth.)

  4. Liquid Salts as Media for Process Heat Transfer from VHTR's: Forced Convective Channel Flow Thermal Hydraulics, Materials, and Coating

    Energy Technology Data Exchange (ETDEWEB)

    Sridharan, Kumar; Anderson, Mark; Allen, Todd; Corradini, Michael

    2012-01-30

    The goal of this NERI project was to perform research on high temperature fluoride and chloride molten salts towards the long-term goal of using these salts for transferring process heat from high temperature nuclear reactor to operation of hydrogen production and chemical plants. Specifically, the research focuses on corrosion of materials in molten salts, which continues to be one of the most significant challenges in molten salts systems. Based on the earlier work performed at ORNL on salt properties for heat transfer applications, a eutectic fluoride salt FLiNaK (46.5% LiF-11.5%NaF-42.0%KF, mol.%) and a eutectic chloride salt (32%MgCl2-68%KCl, mole %) were selected for this study. Several high temperature candidate Fe-Ni-Cr and Ni-Cr alloys: Hastelloy-N, Hastelloy-X, Haynes-230, Inconel-617, and Incoloy-800H, were exposed to molten FLiNaK with the goal of understanding corrosion mechanisms and ranking these alloys for their suitability for molten fluoride salt heat exchanger and thermal storage applications. The tests were performed at 850C for 500 h in sealed graphite crucibles under an argon cover gas. Corrosion was noted to occur predominantly from dealloying of Cr from the alloys, an effect that was particularly pronounced at the grain boundaries Alloy weight-loss due to molten fluoride salt exposure correlated with the initial Cr-content of the alloys, and was consistent with the Cr-content measured in the salts after corrosion tests. The alloys weight-loss was also found to correlate to the concentration of carbon present for the nominally 20% Cr containing alloys, due to the formation of chromium carbide phases at the grain boundaries. Experiments involving molten salt exposures of Incoloy-800H in Incoloy-800H crucibles under an argon cover gas showed a significantly lower corrosion for this alloy than when tested in a graphite crucible. Graphite significantly accelerated alloy corrosion due to the reduction of Cr from solution by graphite and formation

  5. Effect of helium on creep and fatigue (MAT 11)

    International Nuclear Information System (INIS)

    Schroeder, H.

    1991-03-01

    This final report contains experimental results on mechanical properties (creep, fatigue, tensile) and microstructural investigations (SEM, TEM) of pre-implanted samples of steels or alloys. (AISI 316, AISI 316L, DIN 1.4970, JPCA 8206, DIN 1.4914; Incoloy 800H, Hastelloy X, DIN 1.4981, (Fe 0.49 Ni 0.51 ) 3 V, Fe17Ni17Cr, Fe15Ni15Cr, Nimonic PE 16, Ni8Si). Furthermore theoretical aspects and developed models and mechanisms for helium embrittlement are described. This report is presented in the form of an extended summary without figures. (MM)

  6. Correlation of substructure with mechanical properties of plastically deformed reactor structural materials. Progress report, January 1, 1976--June 30, 1977

    International Nuclear Information System (INIS)

    Moteff, J.

    1977-01-01

    Transmission electron microscopy used to evaluate the deformation (creep, fatigue and tensile) induced microstructure of 304 SS, Incoloy 800, 330 SS and three of the experimental alloys (E19, E23 and E36) obtained from the National Alloy Program clearly shows that the relationship between the subgrain size (lambda) and the applied stress (sigma) obeys the equation lambda = Ab (sigma/E) -1 where A is a constant of the order of 4, b the Burgers rector and E is Young's modulus. Hot-hardness studies on 304 SS, 316 SS, Incoloy 800, 2 1 / 4 Cr-1 Mo steels, 330 SS, Inconel 718, PE-16, Inconel 706, M-813 and the above three experimental alloys suggests that reasonable effective activation energies for creep may be obtained through the use of the hardness test as a strength microprobe tool. The ordering of the strength levels obtained through hot-hardness follows quite closely that obtained in tensile tests when those data are available

  7. Properties of super alloys for high temperature gas cooled reactor

    International Nuclear Information System (INIS)

    Izaki, Takashi; Nakai, Yasuo; Shimizu, Shigeki; Murakami, Takashi

    1975-01-01

    The existing data on the properties at high temperature in helium gas of iron base super alloys. Incoloy-800, -802 and -807, nickel base super alloys, Hastelloy-X, Inconel-600, -617 and -625, and a casting alloy HK-40 were collectively evaluated from the viewpoint of the selection of material for HTGRs. These properties include corrosion resistance, strength and toughness, weldability, tube making, formability, radioactivation, etc. Creep strength was specially studied, taking into consideration the data on the creep characteristics in the actual helium gas atmosphere. The necessity of further long run creep data is suggested. Hastelloy-X has completely stable corrosion resistance at high temperature in helium gas. Incoloy 800 and 807 and Inconel 617 are not preferable in view of corrosion resistance. The creep strength of Inconel 617 extraporated to 1,000 deg C for 100,000 hours in air was the greatest rupture strength of 0.6 kg/mm 2 in all above alloys. However, its strength in helium gas began to fall during a relatively short time, so that its creep strength must be re-evaluated in the use for long time. The radioactivation and separation of oxide film in primary construction materials came into question, Inconel 617 and Incoloy 807 showed high induced radioactivity intensity. Generally speaking, in case of nickel base alloys such as Hastelloy-X, oxide film is difficult to break away. (Iwakiri, K.)

  8. Fatigue tests and life estimation of Incoloy alloy 908

    International Nuclear Information System (INIS)

    Feng, J.; Toma, L.S.; Jang, C.H.; Steeves, M.M.

    1997-01-01

    Incoloy reg-sign alloy 908* is a candidate conduit material for Nb 3 Sn cable-in-conduit superconductors. The conduit is expected to experience cyclic loads at 4 K. Fatigue fracture of the conduit is one possible failure mode. So far, fatigue life has been estimated from fatigue crack growth data, which provide conservative results. The more traditional practice of life estimation using S-N curves has not been done for alloy 908 due to a lack of data at room and cryogenic temperatures. This paper presents a series of fatigue test results in response to this need. Tests were performed in reversed bending, rotating bending, and uniaxial fatigue machines. The test matrix included different heat treatments, two load ratios (R=-1 and 0.1), two temperatures (298 and 77 K), and two orientations (longitudinal and transverse). As expected, there is a semi-log linear relation between the applied stress and fatigue life above an applied stress (e.g., 310 MPa for tests at 298 K and R=-1). Below this stress the curves show an endurance limit. The aged and cold-worked materials have longer fatigue lives and higher endurance limits than the others. Different orientations have no apparent effect on life. Cryogenic temperature results in a much high fatigue life than room temperature. A higher tensile mean stress gives shorter fatigue life. It was also found that the fatigue lives of the reversed bending specimens were of the same order as those of the uniaxial test specimens, but were only half the lives of the rotating bending specimens for given stresses. A sample application of the S-N data is discussed

  9. Dynamic behavior and microstructural evolution during moderate to high strain rate hot deformation of a Fe–Ni–Cr alloy (alloy 800H)

    International Nuclear Information System (INIS)

    Cao, Yu; Di, Hongshuang; Zhang, Jiecen; Yang, Yaohua

    2015-01-01

    The objective of the study is to fundamentally understand the dynamic behavior of alloy 800H at moderate to high strain rate using hot compression tests and propose nucleation mechanism associated with dynamic crystallization (DRX). We firstly investigated the dynamic behavior of alloy 800H with industrial scale strain rates using hot compression tests and adiabatic correction was performed to correct as-measured flow curves. Secondly, a Johnson–Cook model was established by using the corrected data and could give a precise prediction of elevated temperature flow stress for the studied alloy. Finally, the nucleation mechanism of DRX grains at high strain rates was studied. The results showed that the predominant nucleation mechanism for DRX is the formation of “bulge” at parent grain boundary. Additionally, the fragmentation of original grain at low deformation temperatures and the twinning near the bulged regions at high deformation temperatures also accelerate the DRX process

  10. Dynamic behavior and microstructural evolution during moderate to high strain rate hot deformation of a Fe-Ni-Cr alloy (alloy 800H)

    Science.gov (United States)

    Cao, Yu; Di, Hongshuang; Zhang, Jiecen; Yang, Yaohua

    2015-01-01

    The objective of the study is to fundamentally understand the dynamic behavior of alloy 800H at moderate to high strain rate using hot compression tests and propose nucleation mechanism associated with dynamic crystallization (DRX). We firstly investigated the dynamic behavior of alloy 800H with industrial scale strain rates using hot compression tests and adiabatic correction was performed to correct as-measured flow curves. Secondly, a Johnson-Cook model was established by using the corrected data and could give a precise prediction of elevated temperature flow stress for the studied alloy. Finally, the nucleation mechanism of DRX grains at high strain rates was studied. The results showed that the predominant nucleation mechanism for DRX is the formation of "bulge" at parent grain boundary. Additionally, the fragmentation of original grain at low deformation temperatures and the twinning near the bulged regions at high deformation temperatures also accelerate the DRX process.

  11. Effects of mean tensile stresses on high-cycle fatigue life and strain accumulation in some reactor materials

    International Nuclear Information System (INIS)

    Soo, P.; Chow, J.G.Y.

    1977-05-01

    An assessment has been made of the effects of mean tensile stresses on the high-cycle fatigue behavior of solution-treated Type 304 stainless steel, normalized and tempered 2 1 / 4 Cr-1Mo steel, Incoloy-800H, and low-carbon Incoloy-800. Mean stresses are usually detrimental to fatigue strength, especially at high temperatures and stress levels, where significant creep can occur during fatigue cycling. Depending on the magnitudes of the alternating and mean stresses, failure may be creep or fatigue controlled. Strain accumulation is also affected by these stress levels and possibly, also, by the cyclic work-hardening characteristics of the material. It is shown that the Goodman Law for estimating mean stress effects is inadequate, since it does not account for time-dependent deformation. An alternative expression not having such a limitation was, therefore, derived and this relates the alternating and mean stresses to the time to failure. Based on limited metallographic observations of fatigue striations in the 2 1 / 4 Cr-1Mo steel an estimate was made of the crack propagation rate. It was found that a crack of critical size could, under certain conditions, propagate through most of the specimen diameter in a matter of seconds. This presents a more significant safety problem than the case for a crack extending under low-cycle conditions since preventative measures probably could not be implemented before the crack had grown to a large size

  12. Modelling the long-term corrosion behaviour of candidate alloys for Canadian SCWR

    Energy Technology Data Exchange (ETDEWEB)

    Steeves, G.; Cook, W., E-mail: wcook@unb.ca, E-mail: graham.steeves@unb.ca [University of New Brunswick, Department of Chemical Engineering, Fredericton, NB (Canada)

    2015-07-01

    Corrosion behaviour of Inconel 625 and Incoloy 800H, two of the candidate fuel cladding materials for Canadian supercritical water (SCW) reactor designs, were evaluated by exposing the metals to SCW in UNB's SCW flow loop. Individual experiments were conducted over a range of 370{sup o}C and 600{sup o}C. Exposure times were typically intervals of 100, 250, and 500 hours. Experimental data was used to create an empirical kinetic equation for each material. Activation energies for the alloys were determined, and showed a distinct difference between low-temperature electrochemical corrosion mechanism and direct high-temperature chemical oxidation. (author)

  13. The influence of cold work on the oxidation behaviour of stainless steel

    International Nuclear Information System (INIS)

    Langevoort, J.C.

    1985-01-01

    In this thesis the study of the interaction of oxygen gas with stainless steel surfaces is described. Thermogravimetry, microscopy and ellipsometry have been used to follow the oxidation in situ, while EDX, AES and XPS have been used to determine the oxide compositions. The aim of this thesis is to reveal the influence on the oxidation behaviour of stainless steel of i) cold work (rolling, drawing, milling, polishing and Ar ion bombardment) ii) the initially formed oxide and iii) the experimental conditions. Two types of stainless steels have been used (AISI 304 (a 18/8 Cr/Ni steel) and Incoloy 800 H (a 20/30 Cr/Ni steel)). (Auth.)

  14. Considerations in selecting tubing materials for CANDU steam generators

    International Nuclear Information System (INIS)

    Hemmings, R.L.

    1978-01-01

    Corrosion resistance is the major consideration in selecting tubing material for CANDU steam generators. Corrosion, and additional considerations, lead to the following steam generator tubing material recommendations: for CANDU-BPHWR's (boiling pressurized heavy water reactors) low-cobalt Incoloy-800; for CANDU-PHWR's (pressurized, non-boiling, heavy water reactors), low-cobalt Monel-400

  15. Evaluation of SCC susceptibility of alloy 800 under CANDU SG secondary-side conditions

    International Nuclear Information System (INIS)

    Liu, S.; Lu, Y.

    2006-01-01

    As part of a coordinated program, AECL is developing a set of tools to aid with the prediction and management of steam generator performance. Although stress corrosion cracking (of Alloy 800) has not been detected in any operating steam generator, for life management it is necessary to develop mechanistic models to predict the conditions under which stress corrosion cracking is plausible. Therefore, constant extension rate tests were carried out for Alloy 800 under various steam generator crevice chemistry conditions at applied potentials. These tests were designed to evaluate the stress corrosion cracking susceptibility of Alloy 800 under CANDU( steam generator operating conditions. Based on the experimental results, the recommended electrochemical corrosion potential/pH zone for Alloy 800 determined by electrochemical polarization measurements was verified with the respect of stress corrosion cracking susceptibility. The effects of lead contamination on the stress corrosion cracking susceptibility of Alloy 800 tubing were also evaluated. The experimental results from constant extension rate tests obtained under applied potentials suggest that Alloy 800 has good performance inside much of a previously recommended electrochemical corrosion potential/pH zone determined by electrochemical analysis. Alloy 800 is not susceptible to stress corrosion cracking under normal CANDU steam generator operating conditions. However, Alloy 800 may be susceptible to stress corrosion cracking under near-neutral crevice chemistry conditions in the presence of oxidants. In addition, stress corrosion cracking susceptibility is increased by lead contamination. This observation suggests that the previously defined electrochemical corrosion potential limit under near-neutral crevice conditions could be modified to minimize stress corrosion cracking of Alloy 800. The test results from this work also suggest that the pH dependency of the stress corrosion cracking susceptibility of Alloy 800

  16. Cosmic ray H and He spectra from 2 to 800 TeV/nucleon from the JACEE experiments

    International Nuclear Information System (INIS)

    Nilsen, B. S.; Cherry, M. L.; Sengupta, K.; Wefel, J. P.; Asakimori, K.; Burnett, T. H.; Iwai, J.; Lord, J.; Olson, E. D.; Strausz, S. C.; Wilkes, R. J.; Zager, E.; Chevli, K.; Gregory, J. C.; Johnson, J.; Shiina, T.; Takahashi, Y.; Christl, M. J.; Derrickson, J. H.; Fountain, W. F.

    1997-01-01

    Results for the cosmic ray hydrogen and helium spectra up to 800 TeV, near the 'knee' region, are presented. There is no sign of a break in either the hydrogen or helium spectra. The differential power law slopes are 2.80±0.04 for hydrogen and 2.68±0.06 for helium. With these new H and He measurements, together with earlier reported results for the heavier elements, the sum of the spectra give an all-particle spectrum that is in good agreement with the all-particle spectrum measured using extensive air showers

  17. Corrosion behavior of alloy 800H (Fe-21Cr-32Ni) in supercritical water

    International Nuclear Information System (INIS)

    Tan, L.; Allen, T.R.; Yang, Y.

    2011-01-01

    Research highlights: → Testing conditions and sample microstructures showed effects on corrosion behaviors. → EBSD and FIB/TEM were used to characterize microstructure in addition to SEM/EDS and XRD. → The formation mechanism of mushroom-shaped oxidation is proposed. → Oxidation thermodynamics and kinetics predict and interpret the corrosion behaviors. - Abstract: The effect of testing conditions (temperature, time, and oxygen content) and material's microstructure (the as-received and the grain boundary engineered conditions) on the corrosion behavior of alloy 800H in high-temperature pressurized water was studied using a variety of characterization techniques. Oxidation was observed as the primary corrosion behavior on the samples. Oxide exfoliation was significantly mitigated on the grain boundary engineered samples compared to the as-received ones. The oxide formation, including some 'mushroom-shaped oxidation', is predicted via a combination of thermodynamics and kinetics influenced by the preferential diffusion of specific species using short-cut diffusion paths.

  18. Compatibility of potential containment materials with molten lithium hydride at 800 C

    International Nuclear Information System (INIS)

    Pawel, S.J.

    1993-01-01

    A series of compatibility experiments has been performed for several stainless steels, carbon steels, and a nickel-base alloy in molten lithium hydride at 800 C for comparison with previous experiments on type 304L stainless steel. The results indicate that the mechanism of corrosion is the same for each of 304L, 304, 316L, and 309 stainless steel and that very similar corrosion in molten LiH is expected for each stainless alloy. Deviation from parabolic kinetics at extended exposure time for each stainless alloy is attributed in part to weight gains associated with lithium penetration. Stabilized (Nb and Ti) low carbon (< 0.06%) steels are observed to be essentially inert in LiH at 800 C with stable carbides and no grain growth. Mild steel (type 1020) is decarburized rapidly and exhibits extensive grain growth in LiH at 800 C. Both steels exhibit weight gains during exposure to molten LiH that are also related in part to lithium penetration. Alloy X (UNS N06002) exhibits extreme corrosion with essentially linear kinetics and dissolution of nickel sufficient to form subsurface voids. (orig.)

  19. Oxidation behavior of steels and Alloy 800 in supercritical water

    International Nuclear Information System (INIS)

    Olmedo, A.M.; Bordoni, R.; Dominguez, G.; Alvarez, M.G.

    2011-01-01

    The oxidation behavior of a ferritic-martensitic steel T91 and a martensitic steel AISI 403 up to 750 h, and of AISI 316L and Alloy 800 up to 336 h in deaerated supercritical water, 450ºC-25 MPa, was investigated in this paper. After exposure up to 750 h, the weight gain data, for steels T91 and AISI 403, was fitted by ∆W=k t n , were n are similar for both steels and k is a little higher for T91. The oxide films grown in the steels were characterized using gravimetry, scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS) and X-ray diffraction. The films were adherent and exhibited a low porosity. For this low oxygen content supercritical water exposure, the oxide scale exhibited a typical duplex structure, in which the scale is composed of an outer iron oxide layer of magnetite (Fe 3 O 4 ) and an inner iron/chromium oxide layer of a non-stoichiometric iron chromite (Fe,Cr) 3 O 4 . Preliminary results, with AISI 316L and Alloy 800, for two exposure periods (168 and 336 h), are also reported. The morphology shown for the oxide films grown on both materials up to 336 h of oxidation in supercritical water, resembles that of a duplex layer film like that shown by stainless steels and Alloy 800 oxide films grown in a in a high temperature and pressure (220-350ºC) of a primary or secondary coolant of a plant. (author) [es

  20. Creep-rupture behavior of 2-1/4 Cr-1 Mo steel, Alloy 800H and Hastelloy Alloy X in a simulated HTGR helium environment

    International Nuclear Information System (INIS)

    Lai, G.Y.; Wolwowicz, R.J.

    1979-12-01

    Creep-rupture testing was conducted on 1 1/4 Cr-1 Mo steel, Alloy 800H and Hastelloy Alloy X in flowing helium containing nominal concentration of following gases: 1500 μatm H 2 , 450 μatm CO, 50 μatm CH 4 , 50 μatm H 2 O and 5 μatm CO 2 . This environment is believed to represent maximum permissible levels of impurities in the primary coolant for the steam-cycle system of a high-temperature gas-cooled reactor (HTGR) when it is operating continuously with a water and/or steam leak at technical specification limits. Two or three heats of material for each alloy were investigated. Tests were conducted at 482 0 C and 760 0 C (1200 0 F and 1400 0 F) for Alloy 800H, and at 760 0 C and 871 0 C (1400 0 F and 1600 0 F) for Hastelloy Alloy X for times up to 10,000 h. Selected tests were performed on same heat of material in both air and helium environments to make a direct comparison of creep-rupture behaviors between two environments. Metallurgical evaluation was performed on selected post test specimens with respect to gas-metal interactions which included oxidation, carburization and/or decarburization. Correlation between gaseous corrosion and creep-rupture behavior was attempted. Limited tests were also performed to investigate the specimen size effects on creep-rupture behavior in the helium environment

  1. Incoloy 800 steam generator tubes stubbing by laser and electron beams process

    International Nuclear Information System (INIS)

    Bonnin, P.; Noel, J.P.; Gauthier, J.P.; Peigney, A.

    1988-01-01

    The electron beam welding conditions are optimized for different thermal cycles and chemical compositions of the fusion zone. The metallurgical and mechanical properties of the joints are described and compared with the properties of laser and TIG welds [fr

  2. Creep behavior of materials for high-temperature reactor application

    International Nuclear Information System (INIS)

    Schneider, K.; Hartnagel, W.; Iischner, B.; Schepp, P.

    1984-01-01

    Materials for high-temperature gas-cooled reactor (HTGR) application are selected according to their creep behavior. For two alloys--Incoloy-800 used for the live steam tubing of the thorium high-temperature reactor and Inconel-617 evaluated for tubings in advanced HTGRs--creep curves are measured and described by equations. A microstructural interpretation is given. An essential result is that nonstable microstructures determine the creep behavior

  3. Chemical decontamination of reactor components

    International Nuclear Information System (INIS)

    Riess, R.; Berthold, H.O.

    1977-08-01

    A solution for the decontamination of reactor components of the primary system was developed. This solution is a modification of the APAC- (Alkaline Permanganate Ammonium Citrate) system described in the literature. The most important advantage of the present solution over the APAC-method is that it does not induce any selective corrosion attack on materials like stainless steel (austenitic), Inconel 600 and Incoloy 800. (orig.) [de

  4. 31 CFR 800.509 - Materiality.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Materiality. 800.509 Section 800.509 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF INVESTMENT... FOREIGN PERSONS Committee Procedures: Review and Investigation § 800.509 Materiality. The Committee...

  5. 49 CFR 800.2 - Organization.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Organization. 800.2 Section 800.2 Transportation... ORGANIZATION AND FUNCTIONS OF THE BOARD AND DELEGATIONS OF AUTHORITY Organization and Functions § 800.2 Organization. The Board consists of five Members appointed by the President with the advice and consent of the...

  6. 10 CFR 800.301 - Monitoring.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Monitoring. 800.301 Section 800.301 Energy DEPARTMENT OF ENERGY LOANS FOR BID OR PROPOSAL PREPARATION BY MINORITY BUSINESS ENTERPRISES SEEKING DOE CONTRACTS AND ASSISTANCE Loan Administration § 800.301 Monitoring. The Secretary shall have the right to audit any and all...

  7. Liquid metal fast breeder reactor steam generator: behaviour of heat exchange tubes in face of a through crack resulting in a contact between sodium and water

    International Nuclear Information System (INIS)

    Quinet, J.L.; Lannou, L.

    1978-01-01

    The results of a survey made Electricite de France on the behaviour of cracked tubes under operating conditions of an industrial steam generator are submitted in this communication. A comparison is made of the tube material: INCOLOY 800, 2 1/4 Cr-1 Mo, 9 Cr-2 Mo land to the initial leak. Finally, a description is given of the self-development process of a water leak into sodium. (author)

  8. 10 CFR 800.304 - Default.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Default. 800.304 Section 800.304 Energy DEPARTMENT OF... ASSISTANCE Loan Administration § 800.304 Default. (a) In the event that the borrower fails to perform the terms and conditions of the loan, the borrower shall be in default and the Secretary shall have the...

  9. Stress corrosion cracking susceptibility of steam generator tubing on secondary side in restricted flow areas

    International Nuclear Information System (INIS)

    Fulger, M.; Lucan, D.; Radulescu, M.; Velciu, L.

    2003-01-01

    Nuclear steam generator tubes operate in high temperature water and on the secondary side in restricted flow areas many nonvolatile impurities accidentally introduced into circuit tend to concentrate. The concentration process leads to the formation of highly aggressive alkaline or acid solutions in crevices, and these solutions can cause stress corrosion cracking (SCC) on stressed tube materials. Even though alloy 800 has shown to be highly resistant to general corrosion in high temperature water, it has been found that the steam generator tubes may crack during service from the primary and/or secondary side. Stress corrosion cracking is still a serious problem occurring on outside tubes in operating steam generators. The purpose of this study was to evaluate the environmental factors affecting the stress corrosion cracking of steam generators tubing. The main test method was the exposure for 1000 hours into static autoclaves of plastically stressed C-rings of Incoloy 800 in caustic solutions (10% NaOH) and acidic chloride solutions because such environments may sometimes form accidentally in crevices on secondary side of tubes. Because the kinetics of corrosion of metals is indicated by anodic polarization curves, in this study, some stressed specimens were anodically polarized in caustic solutions in electrochemical cell, and other in chloride acidic solutions. The results presented as micrographs, potentiokinetic curves, and electrochemical parameters have been compared to establish the SCC behavior of Incoloy 800 in such concentrated environments. (authors)

  10. 47 CFR 65.800 - Rate base.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Rate base. 65.800 Section 65.800 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES (CONTINUED) INTERSTATE RATE OF RETURN PRESCRIPTION PROCEDURES AND METHODOLOGIES Rate Base § 65.800 Rate base. The rate base shall...

  11. 10 CFR 800.002 - Program management.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Program management. 800.002 Section 800.002 Energy DEPARTMENT OF ENERGY LOANS FOR BID OR PROPOSAL PREPARATION BY MINORITY BUSINESS ENTERPRISES SEEKING DOE CONTRACTS AND ASSISTANCE General § 800.002 Program management. Program management responsibility for...

  12. 20 CFR 638.800 - Program management.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Program management. 638.800 Section 638.800... TITLE IV-B OF THE JOB TRAINING PARTNERSHIP ACT Administrative Provisions § 638.800 Program management. (a) The Job Corps Director shall establish and use internal program management procedures sufficient...

  13. 30 CFR 800.21 - Collateral bonds.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Collateral bonds. 800.21 Section 800.21 Mineral... FOR SURFACE COAL MINING AND RECLAMATION OPERATIONS UNDER REGULATORY PROGRAMS § 800.21 Collateral bonds. (a) Collateral bonds, except for letters of credit, cash accounts, and real property, shall be...

  14. 31 CFR 800.201 - Business day.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Business day. 800.201 Section 800.201 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF INVESTMENT... FOREIGN PERSONS Definitions § 800.201 Business day. The term business day means Monday through Friday...

  15. 31 CFR 800.225 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 800.225 Section 800... TAKEOVERS BY FOREIGN PERSONS Definitions § 800.225 United States. The term United States or U.S. means the United States of America, the States of the United States, the District of Columbia, and any commonwealth...

  16. 14 CFR 1212.800 - Civil remedies.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Civil remedies. 1212.800 Section 1212.800... Comply With Requirements of This Part § 1212.800 Civil remedies. Failure to comply with the requirements of the Privacy Act and this part could subject NASA to civil suit under the provisions of 5 U.S.C...

  17. Investigation of the behaviour of 35% nickel alloys in the presence of helium coolant impurities

    International Nuclear Information System (INIS)

    Dixmier, J.; Leclercq, D.; Olivier, P.; Vincent, L.; Willermoz, H.

    1976-01-01

    Alloys of the Incoloy 800 type containing 35% nickel are being considered for the heat exchangers of steam-cycle high-temperature reactors for electricity production. Corrosion tests at 650 and 800 0 C have been carried out at atmospheric pressure and at 50 bar on four such alloys (commercially available and specially produced ones) with different titanium and aluminium contents. It appears that the degree of intergranular attack occurring in these materials increases with the titanium and aluminium concentration. Examination with a scanning electron microscope fitted with analysers confirms the decisive role of these two elements which are actually to be found in oxidized form at the grain boundaries to the exclusion of other components of the alloy. This type of corrosion can lead in the long run to a deterioration in the alloy's mechanical characteristics at high temperature. To assess the true risk of in-service rupture, various rigs have been developed for investigating corrosion under stress conditions. The atmosphere in these rigs consists of helium, of which the impurity content is rigorously controlled. In particular, the Aida high-pressure loop installed at the Grenoble Nuclear Research Centre can accommodate a large number of test-pieces. These are either subjected to a definite tensile stress or placed in a circuit through which helium is passed at high velocity. At present experiments are being conducted at 700 and 750 0 C on an Incoloy 800 alloy corresponding to the designers' specifications. The experiments are performed at atmospheric pressure and a pressure of 50 bar with the same impurity pressures. (author)

  18. 17 CFR 230.800 - Definitions for §§ 230.800, 230.801 and 230.802.

    Science.gov (United States)

    2010-04-01

    ... Rights Offerings, Exchange Offers and Business Combinations § 230.800 Definitions for §§ 230.800, 230.801... combination. Business combination means a statutory amalgamation, merger, arrangement or other reorganization... of the exchange offer or business combination. (f) Home jurisdiction. Home jurisdiction means both...

  19. Effect of the structure on the low-cycle fatigue behaviour of alloy 800

    International Nuclear Information System (INIS)

    Robert, G.; Mathiot, A.; Regnard, C.; Dessus, J.; Claret, J.

    1982-04-01

    Alloy 800 (grade I) is used for making the steam generators of liquid metal fast breeder reactors. At working temperature (525 0 C) alloy 800 is strengthned by γ' (Ni 3 (Ti,Al)) precipitation which occurs during thermal aging. The mechanical properties of this alloy depend on the parameters which define the γ' precipitation and obviously on the structural characteristics due to the thermomechanical treatments which govern the manufacture of the product. For one cast of alloy 800 this work aims to analyse the influence, on low cycle fatigue behaviour at 550 0 C, of structural and microstructural variations originating either in different elaboration procedures or in γ' precipitation obtained by a thermal aging of 3000h at 550 0 C with or without a preceeding cold working of 10% [fr

  20. 24 CFR 241.800 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... SUPPLEMENTARY FINANCING FOR INSURED PROJECT MORTGAGES Contract Rights and Obligations-Multifamily Projects Without a HUD-Insured or HUD-Held Mortgage § 241.800 Definitions. All of the definitions contained in... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Definitions. 241.800 Section 241...

  1. IMac G4/800 (Flat Panel)

    CERN Multimedia

    2002-01-01

    Apple introduced the iMac G4/800 on January 7, 2002. The total cost was about $2000 (base price of $1799 plus RAM upgrade). The iMac G4/800 has an 800 MHz G4 processor. The G4/800 has the following ports: three USB 1.1 ports, two Fire Wire 400-Mbps ports, one RJ-45, 10/100BASE-T Ethernet port, one RJ-11 56K V.90 modem port, one Mini-VGA output port, one speaker jack, and one headphone jack. There is a built in microphone set on the front of the monitor in the bottom left corner. There is a single internal SuperDrive capable of reading and writing CDs and DVDs. The disk drive is on the front of the computer. It opens by pushing the disk drive button on the iMac's keyboard. The monitor size is 15 inches. The G4/800 has a NVIDIA GeForce2 MX graphics processor with AGP 2X support that provides 32 MB of dedicated Double Data Rate (DDR) video memory. Native resolution is 1024 x 768, but the built in monitor is also capable of 640 x 480 and 800 x 600. RAM can be changed by removing a panel on the bottom of the chas...

  2. Corrosion problems of PWR steam generators

    International Nuclear Information System (INIS)

    Urbancik, L.; Kostal, M.

    Literature data are assessed on corrosion failures of steam generator tubes made of INCONEL 600 or INCOLOY 800. It was found that both alloys with high nickel content showed good stability in a corrosion environment while being sensitive to carbide formation on grain boundaries. The gradual depletion of chromium results from the material and corrosion resistance deteriorates. INCOLOY 800 whose chromium carbide precipitation on grain boundaries in pure water and steam is negligible up to 75O degC and which is not subject to corrosion attacks in the above media and in an oxidizing environment at a temperature to about 700 degC shows the best corrosion resistance. Its favourable properties were tested in long-term operation in the Peach Bottom 1 nuclear power plant where no failures due to corrosion of this material have been recorded since 1967. In view of oxygenic-acid surface corrosion, it is necessary to work in a neutral or slightly basic environment should any one of the two alloys be used for steam generator construction. The results are summed up of an analysis conducted for the Beznau I NOK reactor. Water treatment with ash-free amines can be used as prevention against chemical corrosion mechanisms, although the treatment itself does not ensure corrosion resistance of steam generator key components. (J.B.)

  3. 31 CFR 800.204 - Control.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Control. 800.204 Section 800.204 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF INVESTMENT... preferences of the particular class of stock held by minority investors, as provided in the relevant corporate...

  4. 31 CFR 800.211 - Entity.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Entity. 800.211 Section 800.211 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF INVESTMENT... separate legal entity) operated by any one of the foregoing as a business undertaking in a particular...

  5. 7 CFR 800.138 - Conflict of interest.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Conflict of interest. 800.138 Section 800.138 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD... Inspection Services § 800.138 Conflict of interest. Official personnel cannot perform or participate in...

  6. 7 CFR 800.128 - Conflicts of interest.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Conflicts of interest. 800.128 Section 800.128 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD... Reinspection Services and Review of Weighing Services § 800.128 Conflicts of interest. Official personnel...

  7. 30 CFR 800.30 - Replacement of bonds.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Replacement of bonds. 800.30 Section 800.30... REQUIREMENTS FOR SURFACE COAL MINING AND RECLAMATION OPERATIONS UNDER REGULATORY PROGRAMS § 800.30 Replacement... replacement performance bonds. Replacement of a performance bond pursuant to this section shall not constitute...

  8. 33 CFR 117.800 - Mill Neck Creek.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Mill Neck Creek. 117.800 Section 117.800 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY BRIDGES DRAWBRIDGE OPERATION REGULATIONS Specific Requirements New York § 117.800 Mill Neck Creek. The draw of the...

  9. Creep and fatigue of alloy 800 in helium

    International Nuclear Information System (INIS)

    Cook, R.H.

    1975-01-01

    Proposals for use of Alloy 800 as a H.T.R. boiler material have prompted studies of its creep and high temperature fatigue properties in impure helium with comparative tests in air. In impure helium, as expected in a H.T.R., reactions of potential importance are selective oxidation (of chromium, aluminium and titanium) and possibly carburisation from carbon monoxide or methane. In air, general oxidation will occur, possibly accompanied by nitridation. The effects of these reactions will depend on specimen geometry and the nature of the deformation. Two important possibilities are: (i) that environment affects the structure and properties of a surface zone of material undegoing uniform deformation (this may modify creep rate and crack nucleation); and (ii) that environment affects behaviour of a small region (e.g. at the root of a notch or ahead of a crack) in a specimen undergoing non-uniform deformation (this will modify crack growth and hence rupture life or fatigue endurance). This paper summarises experimental work demonstrating an influence of the above reactions on mechanical properties of austenitic steels and nickel-based alloys, drawing examples where possible from the limited data available on Alloy 800. Whilst nitridation and carburisation may simply increase creep resistance at the expense of ductility (and possibly of fatigue resistance), the effects of oxidation are complex. A high oxygen pressures (as in air) oxygen may reduce creep and fatigue resistance by promoting cavitation but formation of oxide in cracks can reduce their propagation rate. At low oxygen pressures, as expected in H.T.R. helium, oxygen enhanced cavitation is less likely, but selective oxidation along grain boundaries can sometimes assist crack nucleation. (author)

  10. 47 CFR 90.672 - Unacceptable interference to non-cellular 800 MHz licensees from 800 MHz cellular systems or part...

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Unacceptable interference to non-cellular 800 MHz licensees from 800 MHz cellular systems or part 22 Cellular Radiotelephone systems, and within the... Procedures and Process-Unacceptable Interference § 90.672 Unacceptable interference to non-cellular 800 MHz...

  11. 7 CFR 800.88 - Loss of identity.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Loss of identity. 800.88 Section 800.88 Agriculture... Methods and Procedures § 800.88 Loss of identity. (a) Lots. Except as noted in paragraph (d) of this... personnel performing a reinspection, appeal inspection, or Board appeal inspection service, the identity of...

  12. 47 CFR 54.800 - Terms and definitions.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Terms and definitions. 54.800 Section 54.800... SERVICE Interstate Access Universal Service Support Mechanism § 54.800 Terms and definitions. (a) Average... § 61.3(d) of this chapter, except that it includes exogenous changes in effect prior to the effective...

  13. Analysis of LTE 800MHz Network Deployment Strategy%LTE 800MHz网络部署策略分析

    Institute of Scientific and Technical Information of China (English)

    余扬尧; 陈杨; 杨芙蓉

    2016-01-01

    Starting ifrst with the current mobile user development situation of the three operators, the paper analyzed the necessity of China telecom LTE 800 MHz network construction, the network coverage, terminal market, construction speed, the business competition, and etc., concluded the short-term, mid-term and long-term deployment strategy for LTE 800 MHz.%首先从当前三大运营商的移动业务用户发展情况入手,分析了中国电信LTE 800 MHz网络建设的必要性,对LTE 800 MHz的网络覆盖、终端市场、建设速度、业务竞争等几个方面进行分析,得出了LTE 800 MHz近、中、远期的部署策略。

  14. 31 CFR 800.226 - U.S. business.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false U.S. business. 800.226 Section 800... TAKEOVERS BY FOREIGN PERSONS Definitions § 800.226 U.S. business. The term U.S. business means any entity... subsidiary is a U.S. business. Corporation A and its branch or subsidiary is each also a foreign person...

  15. Safety of panitumumab-IRDye800CW and cetuximab-IRDye800CW for fluorescence-guided surgical navigation in head and neck cancers.

    Science.gov (United States)

    Gao, Rebecca W; Teraphongphom, Nutte; de Boer, Esther; van den Berg, Nynke S; Divi, Vasu; Kaplan, Michael J; Oberhelman, Nicholas J; Hong, Steven S; Capes, Elissa; Colevas, A Dimitrios; Warram, Jason M; Rosenthal, Eben L

    2018-01-01

    Purpose: To demonstrate the safety and feasibility of leveraging therapeutic antibodies for surgical imaging. Procedures: We conducted two phase I trials for anti-epidermal growth factor receptor antibodies cetuximab-IRDye800CW (n=12) and panitumumab-IRDye800CW (n=15). Adults with biopsy-confirmed head and neck squamous cell carcinoma scheduled for standard-of-care surgery were eligible. For cetuximab-IRDye800CW, cohort 1 was intravenously infused with 2.5 mg/m 2 , cohort 2 received 25 mg/m 2 , and cohort 3 received 62.5 mg/m 2 . For panitumumab-IRDye800CW, cohorts received 0.06 mg/kg, 0.5 mg/kg, and 1 mg/kg, respectively. Electrocardiograms and blood samples were obtained, and patients were followed for 30 days post-study drug infusion. Results: Both fluorescently labeled antibodies had similar pharmacodynamic properties and minimal toxicities. Two infusion reactions occurred with cetuximab and none with panitumumab. There were no grade 2 or higher toxicities attributable to cetuximab-IRDye800CW or panitumumab-IRDye800CW; fifteen grade 1 adverse events occurred with cetuximab-IRDye800CW, and one grade 1 occurred with panitumumab-IRDye800CW. There were no significant differences in QTc prolongation between the two trials (p=0.8). Conclusions: Panitumumab-IRDye800CW and cetuximab-IRDye800CW have toxicity and pharmacodynamic profiles that match the parent compound, suggesting that other therapeutic antibodies may be repurposed as imaging agents with limited preclinical toxicology data.

  16. Mechanical Alterations during 800-m Self-Paced Track Running.

    Science.gov (United States)

    Girard, Olivier; Millet, Gregoire P; Micallef, Jean-Paul

    2017-04-01

    We assessed the time course of running mechanical alterations during an 800-m. On a 200-m indoor track, 18 physical education students performed an 800-m self-paced run. Once per lap, ground reaction forces were measured by a 5-m-long force platform system, and used to determine running kinetics/kinematics and spring-mass characteristics. Compared with 100 m (19.4±1.8 km.h -1 ) running velocity progressively decreased at 300, 500 m but levelled-off at 700 m marks (-5.7±4.6, -10.4±8.3, and -9.1±13.5%, respectively; Ppush-off forces (-5.1±7.2%, P0.05) and leg compression (+2.8±3.9%; P>0.05) remained unchanged, whereas centre of mass vertical displacement (+24.0±7.0%; P0.05). During an 800 m by physical education students, highest running velocity was achieved early during the run, with a progressive decrease in the second half of the trial. While vertical ground force characteristics remained unchanged, non-specialist runners produced lower peak braking and push-off forces, in turn leading to shorter stride length. Spring-mass model characteristics changed toward lower vertical stiffness values, whereas leg stiffness did not change. © Georg Thieme Verlag KG Stuttgart · New York.

  17. 800 C Silicon Carbide (SiC) Pressure Sensors for Engine Ground Testing

    Science.gov (United States)

    Okojie, Robert S.

    2016-01-01

    MEMS-based 4H-SiC piezoresistive pressure sensors have been demonstrated at 800 C, leading to the discovery of strain sensitivity recovery with increasing temperatures above 400 C, eventually achieving up to, or near, 100 recovery of the room temperature values at 800 C. This result will allow the insertion of highly sensitive pressure sensors closer to jet, rocket, and hypersonic engine combustion chambers to improve the quantification accuracy of combustor dynamics, performance, and increase safety margin. Also, by operating at higher temperature and locating closer to the combustion chamber, reduction of the length (weight) of pressure tubes that are currently used will be achieved. This will result in reduced costlb to access space.

  18. Swelling in neutron irradiated nickel-base alloys

    International Nuclear Information System (INIS)

    Brager, H.R.; Bell, W.L.

    1972-01-01

    Inconel 625, Incoloy 800 and Hastelloy X were neutron irradiated at 500 to 700 0 C. It was found that of the three alloys investigated, Inconel 625 offers the greatest swelling resistance. The superior swelling resistance of Inconel 625 relative to that of Hastelloy-X is probably related to differences in the concentrations of the minor rather than major alloy constituents, and can involve (a) enhanced recombination of defects in the Inconel 625 and (b) preferential attraction of vacancies to incoherent precipitates. (U.S.)

  19. 31 CFR 800.207 - Covered transaction.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Covered transaction. 800.207 Section 800.207 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF..., which could result in control of a U.S. business by a foreign person. ...

  20. BN-800 - history and perspective

    International Nuclear Information System (INIS)

    Krivitski, I.Yu.

    2001-01-01

    The sodium cooled fast reactors are one of the most developed and advanced directions of future nuclear engineering. Russia is the first among other countries in field of fast reactor development. The idea of fast reactor designing was proposed in the former Soviet Union by Dr. A.I. Leipunski at the end of 40 th . The successful operation of Russian fast reactors (BOR-60, BN-350 and BN-600 and the world experience proved the feasibility, reliability and safety of this direction of nuclear engineering and allowed to begin the development of the BN-800 reactor project as the commercial fast reactor. In 1992 Russian Government confirmed the construction of BN-800 reactors on South Ural NPP in Chelyabinsk region and on Beloyarskaya NPP. This report presents the brief review on main directions of BN-800 reactor development carrying out in IPPE. (authors)

  1. Molten Chloride Salts for Heat Transfer in Nuclear Systems

    Science.gov (United States)

    Ambrosek, James Wallace

    2011-12-01

    A forced convection loop was designed and constructed to examine the thermal-hydraulic performance of molten KCl-MgCl2 (68-32 at %) salt for use in nuclear co-generation facilities. As part of this research, methods for prediction of the thermo-physical properties of salt mixtures for selection of the coolant salt were studied. In addition, corrosion studies of 10 different alloys were exposed to the KCl-MgCl2 to determine a suitable construction material for the loop. Using experimental data found in literature for unary and binary salt systems, models were found, or developed to extrapolate the available experimental data to unstudied salt systems. These property models were then used to investigate the thermo-physical properties of the LINO3-NaNO3-KNO 3-Ca(NO3), system used in solar energy applications. Using these models, the density, viscosity, adiabatic compressibility, thermal conductivity, heat capacity, and melting temperatures of higher order systems can be approximated. These models may be applied to other molten salt systems. Coupons of 10 different alloys were exposed to the chloride salt for 100 hours at 850°C was undertaken to help determine with which alloy to construct the loop. Of the alloys exposed, Haynes 230 had the least amount of weight loss per area. Nickel and Hastelloy N performed best based on maximum depth of attack. Inconel 625 and 718 had a nearly uniform depletion of Cr from the surface of the sample. All other alloys tested had depletion of Cr along the grain boundaries. The Nb in Inconel 625 and 718 changed the way the Cr is depleted in these alloys. Grain-boundary engineering (GBE) of Incoloy 800H improved the corrosion resistance (weight loss and maximum depth of attack) by nearly 50% as compared to the as-received Incoloy 800H sample. A high temperature pump, thermal flow meter, and pressure differential device was designed, constructed and tested for use in the loop, The heat transfer of the molten chloride salt was found to

  2. 31 CFR 800.208 - Critical infrastructure.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Critical infrastructure. 800.208 Section 800.208 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE... infrastructure means, in the context of a particular covered transaction, a system or asset, whether physical or...

  3. Solubility of apatite in H2O-NaCl and silicate-bearing solutions at 0.7-3.0 GPa, 800° C

    Science.gov (United States)

    Antignano, A.; Manning, C. E.

    2004-12-01

    Apatite is a major reservoir for the rare-earth elements (REE) in the earth's crust. However, little is known about its solubility in metamorphic fluids. We measured the solubility of apatite in H2O-NaCl and silicate bearing fluids at 800° C and 1.0-2.0 GPa using a piston-cylinder apparatus with NaCl-graphite furnaces. A single Durango fluor-apatite crystal was loaded into a 1.6 mm OD Pt inner capsule, which was crimped and then placed in a 3.5 OD Pt outer capsule with ultra pure H2O and NaCl or powdered albite. Solubility was determined by the weight loss of the apatite grain after 24 hrs. In the H2O-NaCl experiments, total dissolved solids (TDS) were initially below detection (0.4 millimolal) between XNaCl= 0 and XNaCl= 0.025. At XNaCl= 0.035, solubility was 3.3(0.2) millimolal (errors are 1s), and it increased to 57.5(0.4) millimolal at XNaCl= 0.526. Our results show that there is an enhancement in apatite solubility with increasing pressure in pure H2O. Solubility is initially below detection at bearing solutions. This probably explains textures in which monazite mantles apatite, which are common in granulite metamorphic terranes, such as the Kiirunavaara magnetite-apatite ore.

  4. 31 CFR 800.212 - Foreign entity.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Foreign entity. 800.212 Section 800.212 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... business is outside the United States or its equity securities are primarily traded on one or more foreign...

  5. 10 CFR 800.306 - Noninterference with other laws.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Noninterference with other laws. 800.306 Section 800.306 Energy DEPARTMENT OF ENERGY LOANS FOR BID OR PROPOSAL PREPARATION BY MINORITY BUSINESS ENTERPRISES SEEKING DOE CONTRACTS AND ASSISTANCE Loan Administration § 800.306 Noninterference with other laws...

  6. Effect of lead and silicon on localized corrosion of Alloy 800 in steam generator crevice environments

    International Nuclear Information System (INIS)

    Lu, Y.C.; Wright, M.D.; Cleland, R.D.

    2001-09-01

    The Alloy 800 tubes used in CANDU 6 steam generators have not experienced significant corrosion damage to date, which may be attributed to successful water chemistry control strategies. However, it is known that Alloy 800, like other steam generator (SG) tubing materials, is not immune to corrosion, especially pitting, under some plausible but off-specification operating scenarios. Electrochemical measurements provide information on corrosion susceptibility and rate, which are known to be a function of water chemistry. Using laboratory data in combination with chemistry monitoring and diagnostic software it is possible to assess the impact of plant operating conditions on SG tube corrosion for plant life management (PLIM). In this context, this paper discusses the results of electrochemical measurements made to elucidate the corrosion behaviour of Alloy 800 SG tubes under conditions simulating those plausible in SG crevices. In addition to crevice pH, the influence of PbO, acting alone or in combination with SiO 2 , on localized corrosion such as pitting or stress corrosion-cracking (SCC) was determined. Possible transient chemistry regimes that could significantly shorten expected tube lifetimes have been identified from the data analysis. Of equal significance, the results also support the position that under normal, near neutral pH and low dissolved oxygen conditions, pitting and cracking of Alloy 800 steam generator tubing will not be initiated. (author)

  7. 30 CFR 75.800-1 - Circuit breakers; location.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Circuit breakers; location. 75.800-1 Section 75.800-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... § 75.800-1 Circuit breakers; location. Circuit breakers protecting high-voltage circuits entering an...

  8. 31 CFR 800.303 - Lending transactions.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Lending transactions. 800.303 Section 800.303 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... the creation in the foreign person of a secured interest in securities or other assets of the U.S...

  9. 7 CFR 800.116 - How to request original services.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false How to request original services. 800.116 Section 800... Original Services § 800.116 How to request original services. (a) General. Except as otherwise provided for in § 800.117, requests for original services shall be filed with an agency or field office authorized...

  10. 7 CFR 800.199 - Conflict-of-interest provisions.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Conflict-of-interest provisions. 800.199 Section 800... Delegations, Designations, Approvals, Contracts, and Conflicts of Interest § 800.199 Conflict-of-interest...) Prohibited conflicts of interest. Unless waived on a case-by-case basis by the Administrator under section 11...

  11. Research on the hot deformation behavior of a Fe-Ni-Cr alloy (800H) at temperatures above 1000 °C

    Science.gov (United States)

    Cao, Yu; Di, Hongshuang

    2015-10-01

    Considering the pinning effect of fine carbides on grain boundaries, hot compression tests were performed above the dissolution temperature of Cr23C6 to investigate the hot deformation behavior of a Fe-Ni-Cr alloy (800H). The results show that the single peak stress associated with dynamic recrystalization (DRX) became more distinct at higher temperature and lower strain rate. The process of DRX was thoroughly stimulated when deformed above 1000 °C. Constitutive equations for hot deformation were established by regression analysis of conventional hyperbolic sine equation. The relationships between Zener-Hollomon parameter (Z) and the characteristic points of flow curves were established using the power law relation. Furthermore, kernel average misorientation (KAM) and grain orientation spread (GOS) were used to map the distribution of local misorientation and estimate the fraction of DRX, respectively. The critical strain and peak strain were used to predict the kinetics of DRX with the Avrami-type equation.

  12. 7 CFR 800.99 - Checkweighing sacked grain.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Checkweighing sacked grain. 800.99 Section 800.99 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD ADMINISTRATION (FEDERAL GRAIN INSPECTION SERVICE), DEPARTMENT OF AGRICULTURE GENERAL REGULATIONS Weighing...

  13. The welding of alloy 800

    International Nuclear Information System (INIS)

    Ward, M.; Norman, P.L.

    1975-01-01

    This paper reviews the technical literature published on the welding of alloy 800. Much of this work has been carried out using the Varestraint and Gleeble tests to investigate the susceptibility of the alloy and of high nickel consumables to hot-cracking. Inspite of much reported work, it is pointed out that many years of experience in the use of alloy 800 shows it to be readily weldable without any major problems occurring due to hot-cracking. The elements investigated include titanium, aluminium, sulphur, phosphorus and carbon, and the effects of these elements are discuused in terms of their effects on the hot-ductility curves obtained by Gleeble testing. Conclusions reached by various researchers state that the individual effects of the above five elements may be masked by other unknown factors. It is concluded that with correct welding procedures alloy 800 can be welded without cracking problems even with high heat input welding processes using either high-nickel filler wires or a matching electrode. Matching composition filler wires have been used with success but none are at present available commercially. (author)

  14. 7 CFR 800.25 - Required elevator and merchandising records.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Required elevator and merchandising records. 800.25 Section 800.25 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION... REGULATIONS Recordkeeping and Access to Facilities § 800.25 Required elevator and merchandising records. (a...

  15. 7 CFR 800.115 - Who may request original services.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Who may request original services. 800.115 Section 800... Original Services § 800.115 Who may request original services. (a) General. Any interested person may request original inspection and weighing services. The kinds of inspection and weighing services are...

  16. Effect of aging and cold working on the high-temperature low-cycle fatigue behavior of alloy 800H. Part I. The effect of hardening processes on the initial stress--strain curve

    International Nuclear Information System (INIS)

    Villagrana, R.E.; Kaae, J.L.; Ellis, J.R.; Gantzel, P.K.

    1978-01-01

    The individual and combined effects of cold working (5 and 10%) and aging (4000 and 8000 h at 538 to 760 0 C) on the microstructure and high-temperature yield strength of alloy 800H have been investigated. The specimens were tested at the aging temperatures. During testing some of the specimens showed the phenomenon of serrated yielding. In order of importance, the principal hardening agents observed in this work were: cold work, the precipitation of Cr 23 C 6 at the grain boundaries, and, in some cases, the precipitation of a Perovskite-type γ' phase in the grain interiors

  17. Study of Oxide Formation on Alloy 800 by Potentiostatic Polarization

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Chong Hun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Momenib, M.; Wren, C. J. [University of Western Ontario, London (Canada)

    2015-10-15

    The objectives of study are to investigate the effect of potential on oxide formation and conversion on alloy 800 under potentiostatic conditions. For this study we have focused primarily on corrosion at pH{sub 25.}deg. C8.4. The results presented in Figures 1 show that in the range from -0.8 V{sub SCE} to +0.2 V{sub SCE} there are four potential regions having distinctly different short- and long-term characteristics in the log |i| vs. log t and Q vs. t plots. At a potential below -0.8 V{sub SCE}, the current becomes cathodic immediately (< 10 s) upon polarization, indicating negligible metal oxidation and hence is not of interest. In nuclear power plants, it is used for steam generator tubing in pressurized water reactors (PWRs), including Canadian Deuterium Uranium (CANDU) reactors. However, failures resulting from localized corrosion such as pitting, crevice and stress corrosion cracking (SCC) have been observed in the service environments. There exists still considerable controversy over the type of oxide that can be formed and the mechanism of oxide formation on Alloy 800.

  18. Near-Infrared Fluorescence Detection of Acetylcholine in Aqueous Solution Using a Complex of Rhodamine 800 and p-Sulfonato-calix[8]arene

    Science.gov (United States)

    Jin, Takashi

    2010-01-01

    The complexing properties of p-sulfonatocalix[n]arenes (n = 4: S[4], n = 6: S[6], and n = 8: S[8]) for rhodamine 800 (Rh800) and indocyanine green (ICG) were examined to develop a near-infrared (NIR) fluorescence detection method for acetylcholine (ACh). We found that Rh800 (as a cation) forms an inclusion complex with S[n], while ICG (as a twitter ion) have no binding ability for S[n]. The binding ability of Rh800 to S[n] decreased in the order of S[8] > S[6] >> S[4]. By the formation of the complex between Rh800 and S[8], fluorescence intensity of the Rh800 was significantly decreased. From the fluorescence titration of Rh800 by S[8], stoichiometry of the Rh800-S[8] complex was determined to be 1:1 with a dissociation constant of 2.2 μM in PBS. The addition of ACh to the aqueous solution of the Rh800-S[8] complex caused a fluorescence increase of Rh800, resulting from a competitive replacement of Rh800 by ACh in the complex. From the fluorescence change by the competitive fluorophore replacement, stoichiometry of the Rh800-ACh complex was found to be 1:1 with a dissociation constant of 1.7 mM. The effects of other neurotransmitters on the fluorescence spectra of the Rh800-S[8] complex were examined for dopamine, GABA, glycine, and l-asparatic acid. Among the neurotransmitters examined, fluorescence response of the Rh800-S[8] complex was highly specific to ACh. Rh800-S[8] complexes can be used as a NIR fluorescent probe for the detection of ACh (5 × 10−4−10−3 M) in PBS buffer (pH = 7.2). PMID:22294934

  19. The one-parameter-model - a constitutive equation applied to a heat resistant alloy

    International Nuclear Information System (INIS)

    Schwarze, E.; Schuster, H.; Nickel, H.

    1992-01-01

    In the present work a constitutive model earlier developed and used to predict experimental results of hot tests and fatigue tests from creep experiments of metallic materials were modified to comply with the properties of a high temperature resistant material. The improved model accounts for the properties of a material developing a density and a structure of dislocation lines which are capable of interactions with particles (carbides) from a second phase. The time and temperature dependent evolution of the carbide structure has been described by an equation which explains the formation of seeds as well as their growths (Ostwald ripening). The extended model was applied to Incoloy 800H which is known to develop a carbide structure. Therefore hot tensile and fatigue tests, creep and relaxation experiments using the heats ADU and BAK (KFA specifications) at temperature between 800deg C and 900deg C were performed including both solution treated specimens and specimens heat treated for 10, 100 and 1000 hours. As compared with the results from tensile tests where the carbide structures play a subordinated role, alternately, these structures have a decisive influence on the creep properties of specimens during the primary creep phase, i.e. low stresses and high temperatures. (orig.) [de

  20. A Field-Shaking System to Reduce the Screening Current-Induced Field in the 800-MHz HTS Insert of the MIT 1.3-GHz LTS/HTS NMR Magnet: A Small-Model Study.

    Science.gov (United States)

    Lee, Jiho; Park, Dongkeun; Michael, Philip C; Noguchi, So; Bascuñán, Juan; Iwasa, Yukikazu

    2018-04-01

    In this paper, we present experimental results, of a small-model study, from which we plan to develop and apply a full-scale field-shaking system to reduce the screening current-induced field (SCF) in the 800-MHz HTS Insert (H800) of the MIT 1.3-GHz LTS/HTS NMR magnet (1.3G) currently under construction-the H800 is composed of 3 nested coils, each a stack of no-insulation (NI) REBCO double-pancakes. In 1.3G, H800 is the chief source of a large error field generated by its own SCF. To study the effectiveness of the field-shaking technique, we used two NI REBCO double-pancakes, one from Coil 2 (HCoil2) and one from Coil 3 (HCoil3) of the 3 H800 coils, and placed them in the bore of a 5-T/300-mm room-temperature bore low-temperature superconducting (LTS) background magnet. The background magnet is used not only to induce the SCF in the double-pancakes but also to reduce it by the field-shaking technique. For each run, we induced the SCF in the double-pancakes at an axial location where the external radial field Br > 0, then for the field-shaking, moved them to another location where the external axial field Bz ≫ B R . Due to the geometry of H800 and L500, top double-pancakes of 3 H800 coils will experience the considerable radial magnetic field perpendicular to the REBCO tape surface. To examine the effect of the field-shaking on the SCF, we tested each NI REBCO DP in the absence or presence of a radial field. In this paper, we report 77-K experimental results and analysis of the effect and a few significant remarks of the field-shaking.

  1. Fatigue and fatigue crack growth properties of 316LN and Incoloy 908 below 10 K

    International Nuclear Information System (INIS)

    Nyilas, A.; Zhang, J.; Obst, B.; Ulbricht, A.

    1992-01-01

    The cyclic loading characteristics of Tokamak type thermonuclear machines demand study of the fatigue response of the materials used in critical components. The large superconducting magnets and their superconductors will operate under cyclic mechanical stress conditions. The present paper is biased towards the current superconductor design of the NET (Next European Torus) model coil concept. The superconductor of this coil will be a cable-in-conduit Nb 3 Sn type with an enveloped stiff external jacket structure. The wall thickness of the jacket structure is within the range of 4-5 mm. The manufacturing of the jacket lengths for several hundred meters require an appropriate joining process due to the prefabricated section pieces available only in short lengths of 5-7 meters. The recently anticipated solution favors the flash butt welding technique. The performance of the superconductors jacket will depend on the material selection and the proper structural design according to the existing low temperature structural materials data base. The wind and react Nb 3 Sn-manufacturing process must also account the materials properties after ageing. A program was set up to elucidate the fatigue-life behavior and fatigue crack growth rate (FCGR) of the selected two candidate materials. These materials were the AISI 316LN with a specified low carbon content to avoid the embrittlement after the ageing process and the Incoloy 908. The 316LN material in the as received condition was tested with respect to its fatigue-life for specimens bearing predefined flaws and cracks. The propagation of surface cracks at 12 K and at 295 K was characterized with non standard specimens. The tests were performed in a cryogenic dynamic test facility under helium gas environment between 7 K and 20 K. Using the reference growth laws obtained from these measurements the total crack propagation starting with the initial crack length of the specimen could be predicted by numerical computation

  2. Alloy 800 specifications in compliance with component requirements

    International Nuclear Information System (INIS)

    Diehl, H.; Bodmann, E.

    1990-01-01

    In view of the importance of the material Alloy 800 in high-temperature reactor plants (HTR), a material data bank was established which is used for statistical evaluation of mechanical and physical material behaviour. Based on investigations on the interconnection between the mechanical properties at high temperatures and the metallurgical parameters, different types of Alloy 800 were specified in compliance with the component requirements. In addition, aspects of corrosion and toughness behaviour were taken into consideration. The specifications and strength characteristics for the different variants of Alloy 800 were incorporated into draft DIN standards after discussion and approval in expert committees. Further important characteristics of the mechanical and physical material behaviour were summarized in HTR material data sheets so as to furnish an improved basis for the design and stress analyses of Alloy 800 components. (orig.)

  3. FTIR study of the influence of minor alloying elements on the high temperature oxidation of nickel alloys

    International Nuclear Information System (INIS)

    Lenglet, M.; Delaunay, F.; Lefez, B.

    1997-01-01

    The purpose of this paper is to study the reflectance spectra of the different single oxide layer systems : Cr 2 O 3 /Fe, MnCr 2 O 4 /Fe, TiO 2 /Fe, NiCr 2 O 4 /Fe and NiFe 2 O 4 /Fe and to extend the theoretical calculations to multilayer oxide systems on metallic substrates. The interpretation of the resulting reflectance spectra for these systems is used to explain the initial stages of oxide formation and the influence of minor alloying elements on the high temperature oxidation of three commercial nickel alloys : Incoloy 800, Inconel 600 and X. (orig.)

  4. Properties and application study of Inconel alloy tube made in China

    International Nuclear Information System (INIS)

    Yang Xiang; Su Xingwan; Wen Yan

    1997-01-01

    The mech-physical properties and the corrosion resistance properties of the SG tube of Inconel alloy made in China under any conditions are briefly presented, and the test and research for bending and expending the tubes have been performed. In the process of corrosion experiments the Inconel alloy tubes were compared with that of the same kind of materials made in foreign countries. The Inconel alloy tubes have better stress corrosion resistance cracking prosperities than Inconel 600 and Incoloy 800 when they were in the solutions which contained high concentrated chlorine ion and alkali at high temperature

  5. Fabrication and loading of long-term stress corrosion cracking surveillance specimens for the Dresden 1 decontamination program

    International Nuclear Information System (INIS)

    Walker, W.L.

    1979-10-01

    Stress-corrosion cracking test specimens were prepared for Dow Nuclear Services for insertion in the Dresden 1 reactor during the chemical decontamination of the primary system, and for subsequent exposure under operating conditions when the station returns to service. The specimens consist of pressurized tubes fabricated from Type-304 and -304L stainless steel, Inconel 600, Incoloy 800, and Zircaloy 2. In addition, constant radius bent-beam specimens of 3/4 hard Type-410 stainless steel were also included. All specimens were stressed to, or slightly above, their respective 0.2% offset yield strengths at the temperatures of interest

  6. Thermal cycling influence on microstructural characterization of alloys with high nickel content

    International Nuclear Information System (INIS)

    Abrudeanu, M.; Gradin, O.; Vulpe, S. C.; Ohai, D.

    2013-01-01

    The IV nuclear energy generation systems are aimed at making revolutionary improvements in economics, safety and reliability, and sustainability. To achieve these goals, Generation IV systems will operate at higher temperatures and in higher radiation fields. This paper shows the thermal cycling influences on microstructure and hardness of nickel based alloys: Incoloy 800 HT and Inconel 617. These alloys were meekly at a thermal cycling of 25, 50, 75 and 100 cycles. The temperature range of a cycle was between 400 O C and 700 O C. Nickel base alloys develop their properties by solid solution and/or precipitation strengthening. (authors)

  7. 7 CFR 800.30 - Foreign commerce grain business.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Foreign commerce grain business. 800.30 Section 800.30 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD ADMINISTRATION (FEDERAL GRAIN INSPECTION SERVICE), DEPARTMENT OF AGRICULTURE GENERAL REGULATIONS Registration...

  8. Structural behaviour of a welded superalloy cylinder with internal pressure in a high temperature environment

    International Nuclear Information System (INIS)

    Udoguchi, T.; Nakanishi, T.

    1981-01-01

    Steady and cyclic creep tests with internal pressure were performed at temperatures of 800 to 1000 0 C on Hastelloy X cylinders with and without a circumferential Tungsten Inert Gas (TIG) welding technique. The creep rupture strength of the TIG welded cylinders was much lower than that of the non-welded cylinders whilst creep rupture strength reduction by the TIG technique was not observed in uniaxial creep tests. The reason for the low creep strength of welded cylinders is discussed and it is noted that the creep ductility of weld metal plays an essentially important role. In order to improve the creep strength of the TIG welded cylinder, various welding procedures with assorted weld metals were investigated. Some improvements were obtained by using welding techniques which had either Incoloy 800 or a modified Hastelloy X material as the filler metal. (U.K.)

  9. 42 CFR 423.800 - Administration of subsidy program.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Administration of subsidy program. 423.800 Section 423.800 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICARE PROGRAM VOLUNTARY MEDICARE PRESCRIPTION DRUG BENEFIT Premiums and Cost...

  10. Bithermal and isothermal experimental test design and resulting influence on the pore formation during high-temperature-induced fatigue of the alloy 800 H

    International Nuclear Information System (INIS)

    Hurta, S.

    1991-01-01

    For investigating the damaging mechanism, bithermal TMF tests have been carried out with the alloy 800H, applying fast pressure half-cycles at low temperature (e.g. 300 C) and slow tensile phases at high temperature (e.g. 700 C). The experimental data thus obtained have been compared with the results of isothermal tests performed at 700 C. Most of the experiments have been performed stress-controlled and with a constant range of plastic strain. Under this regime, deformation is induced in the case of asymmetric test design within the tensile load phase, at various constant tensile stresses each, wheras in the compressive load phase, the stress is constantly increased for compressive stress-governed testing. The results obtained from both test types show that the type of compressive load phase is the factor governing the efficiency of pore formation. (orig.) [de

  11. 30 CFR 800.70 - Bonding for anthracite operations in Pennsylvania.

    Science.gov (United States)

    2010-07-01

    ... Pennsylvania. 800.70 Section 800.70 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT... REGULATORY PROGRAMS § 800.70 Bonding for anthracite operations in Pennsylvania. (a) All of the provisions of... operations in Pennsylvania except that— (1) Specified bond limits shall be determined by the regulatory...

  12. 31 CFR 800.214 - Foreign government-controlled transaction.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Foreign government-controlled transaction. 800.214 Section 800.214 Money and Finance: Treasury Regulations Relating to Money and Finance... control of a U.S. business by a foreign government or a person controlled by or acting on behalf of a...

  13. 31 CFR 800.102 - Effect on other law.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Effect on other law. 800.102 Section... TAKEOVERS BY FOREIGN PERSONS General § 800.102 Effect on other law. Nothing in this part shall be construed..., or review provided by or established under any other provision of federal law, including the...

  14. A better cure rate with 800 mg than with 400 mg clarithromycin regimens in one-week triple therapy for Helicobacter pylori infection in cigarette-smoking peptic ulcer patients.

    Science.gov (United States)

    Ishioka, Hidehiko; Mizuno, Motowo; Take, Susumu; Ishiki, Kuniharu; Nagahara, Yasuhiro; Yoshida, Tomowo; Okada, Hiroyuki; Yokota, Kenji; Oguma, Keiji

    2007-01-01

    In Helicobacter pylori eradication therapy, using a proton pump inhibitor plus amoxicillin and clarithromycin (PPI/AC regimen), the impact of the clarithromycin dose and smoking on efficacy is conflicting. Here, we compared the efficacy of 400 and 800 mg of clarithromycin in the regimen in relation to smoking in patients with peptic ulcer disease. We studied 601 H. pylori-positive patients with peptic ulcer disease who had received amoxicillin 750 mg and clarithromycin 200 or 400 mg together with lansoprazole 30 mg b.i.d. 305 patients were treated with a regimen containing 400 mg of clarithromycin (C400 group), and 296 patients with a regimen containing 800 mg (C800 group). Overall cure rates between the two groups were not significantly different, but the cure rate in the C800 group was significantly better than that in the C400 group among patients infected with clarithromycin-sensitive strains (p = 0.03). This difference could be attributed to differences among smokers versus non-smokers: the cure rate among smokers in the C800 group (91.0%) was better than that in the C400 group (80.0%, p = 0.003). 800 mg of clarithromycin is recommended in the PPI/AC regimen for patients who smoke and are infected with clarithromycin-sensitive H. pylori. 2007 S. Karger AG, Basel

  15. Reduction of tritium permeation through Inconel 718 and Incoloy 800 HT by means of natural oxides

    Energy Technology Data Exchange (ETDEWEB)

    Aiello, A., E-mail: antonio.aiello@enea.it [ENEA C.R. Brasimone, I-40032 Camugnano (Italy); Utili, M.; Ciampichetti, A. [ENEA C.R. Brasimone, I-40032 Camugnano (Italy)

    2011-10-01

    Chronical releases of tritium from the helium primary coolant into the water secondary coolant is a fundamental safety issue in the design of a fusion reactor steam generator. It is well known that the steam/water circuit of a fusion reactor would be considered not relevant from a radiological point of view, while if a strong permeation of tritium will be present it will be released together with incondensable gases in the condenser. The permeation of hydrogen isotopes through candidate steam generator materials in different conditions was studied in the past. Further experiments demonstrated that nickel alloys of nuclear interest are always covered by a thin and adherent oxide layer able to reduce permeation of orders of magnitude. The major objective of this work is the evaluation of the permeated flux through nickel alloys, when exposed to pure hydrogen and to an oxidant gas stream, to verify the real permeability of these materials in conditions close to those foreseen in the helium side of the steam generator.

  16. 7 CFR 800.16 - Certification requirements for export grain.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Certification requirements for export grain. 800.16 Section 800.16 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD ADMINISTRATION (FEDERAL GRAIN INSPECTION SERVICE), DEPARTMENT OF AGRICULTURE GENERAL...

  17. 31 CFR 800.217 - Hold.

    Science.gov (United States)

    2010-07-01

    ... and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF INVESTMENT... FOREIGN PERSONS Definitions § 800.217 Hold. The terms hold(s) and holding mean legal or beneficial ownership, whether direct or indirect, whether through fiduciaries, agents, or other means. ...

  18. Current CTR-related tritium handling studies at ORNL

    International Nuclear Information System (INIS)

    Watson, J.S.; Bell, J.T.; Clinton, S.D.; Fisher, P.W.; Redman, J.D.; Smith, F.J.; Talbot, J.B.; Tung, C.P.

    1976-01-01

    The Oak Ridge National Laboratory has a comprehensive program concerned with plasma fuel recycle, tritium recovery from blankets, and tritium containment in fusion reactors. Two studies of most current interest are investigations of cryosorption pumping of hydrogen isotopes and measurements of tritium permeation rates through steam generator materials. Cryosorption pumping speeds have been measured for hydrogen, deuterium, and helium at pressures from 10 -8 torr to 3 x 10 -3 torr. Permeation rates through Incoloy 800 have been shown to be drastically reduced when the low pressure side of permeation tubes are exposed to steam. These results will be important considerations in the design of fusion reactor steam generators

  19. 14 CFR 1206.800 - Failure to release records to the public.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Failure to release records to the public. 1206.800 Section 1206.800 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION AVAILABILITY OF AGENCY RECORDS TO MEMBERS OF THE PUBLIC Failure To Release Records to the Public § 1206.800...

  20. Exclusive measurement of the Ne = Pb → π ±, H, He at E/A = 400 and 800 MeV

    International Nuclear Information System (INIS)

    Poitou, J.; Babinet, R.; De Marco, N.

    1987-06-01

    This work is part of a systematic investigation of Ne-nucleus collisions undertaken with the 4 π detector Diogene. Only data obtained with Ne at 400 and 800 MeV/A on Pb nuclei are presented. Experimental data are also compared with the resuts of an intranuclear cascade calculation which takes, into account nuclear binding, Pauli blocking and isospin

  1. 48 CFR 219.800 - General.

    Science.gov (United States)

    2010-10-01

    ... (Acquisition, Technology, and Logistics) its authority under paragraph 8(a)(1)(A) of the Small Business Act (15... DEFENSE SOCIOECONOMIC PROGRAMS SMALL BUSINESS PROGRAMS Contracting With the Small Business Administration (The 8(a) Program) 219.800 General. (a) By Partnership Agreement (PA) between the Small Business...

  2. 21 CFR 522.800 - Droperidol and fentanyl citrate injection.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Droperidol and fentanyl citrate injection. 522.800... § 522.800 Droperidol and fentanyl citrate injection. (a) Specifications. Droperidol and fentanyl citrate injection is a sterile solution containing 20 milligrams of droperidol and 0.4 milligram of fentanyl citrate...

  3. 7 CFR 800.117 - Who shall perform original services.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Who shall perform original services. 800.117 Section... REGULATIONS Original Services § 800.117 Who shall perform original services. (a) General. Original services... official agency is not available on a regular basis to provide original services, and no official agency...

  4. 8 CFR 204.308 - Where to file Form I-800A or Form I-800.

    Science.gov (United States)

    2010-01-01

    ... IMMIGRANT PETITIONS Intercountry Adoption of a Convention Adoptee § 204.308 Where to file Form I-800A or... adjudicate the child's application for an immigrant or nonimmigrant visa has jurisdiction to grant final.... When, and if, USCIS adopts electronic, internet-based or other digital means for filing Convention...

  5. An experimental study of the solubility of molybdenum in H2O and KCl-H2O solutions from 500 ºC to 800 ºC, and 150 to 300 MPa

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, Thomas; Mavrogenes, John [Australian National University

    2008-04-22

    The solubility of molybdenum (Mo) was determined at temperatures from 500 °C to 800 °C and 150 to 300 MPa in KCl-H2O and pure H2O solutions in cold-seal experiments. The solutions were trapped as synthetic fluid inclusions in quartz at experimental conditions, and analyzed by laser ablation inductively coupled plasma mass spectrometry (LA ICPMS). Mo solubilities of 1.6 wt% in the case of KCl-bearing aqueous solutions and up to 0.8 wt% in pure H2O were found. Mo solubility is temperature dependent, but not pressure dependent over the investigated range, and correlates positively with salinity (KCl concentration). Molar ratios of ~1 for Mo/Cl and Mo/K are derived based on our data. In combination with results of synchrotron X-ray absorption spectroscopy of individual fluid inclusions, it is suggested that Mo-oxo-chloride complexes are present at high salinity (>20 wt% KCl) and ion pairs at moderate to low salinity (<11 wt% KCl) in KCl-H2O aqueous solutions. Similarly, in the pure H2O experiments molybdic acid is the dominant species in aqueous solution. The results of these hydrothermal Mo experiments fit with earlier studies conducted at lower temperatures and indicate that high Mo concentrations can be transported in aqueous solutions. Therefore, the Mo concentration in aqueous fluids seems not to be the limiting factor for ore formation, whereas precipitation processes and the availability of sulfur appear to be the main controlling factors in the formation of molybdenite (MoS2).

  6. From Viking to Crusader. Scandinavia and Europe 800-1200

    DEFF Research Database (Denmark)

    1st edtion in Danish: Viking og Hvidekrist. Norden og Europa 800-1200, 1992; 2nd edition 1993. Swedish edition: Från Vikingar till Korsfarare, 1992. German edition: Wikinger Waräger Normannen. Die Skandinavier und Europa 800-1200, 1992. French edition with J.-P. Mohen & F.-X. Dillmann: Les Vikings...

  7. Comparison study of the rates of manual peripheral blood smear review from 3 automated hematology analyzers, Unicel DxH 800, ADVIA 2120i, and XE 2100, using international consensus group guidelines.

    Science.gov (United States)

    Kim, Sue Jung; Kim, Yoonjung; Shin, Saeam; Song, Jaewoo; Choi, Jong Rak

    2012-11-01

    In the clinical laboratory, it is important both to reduce the number of peripheral blood slide reviews to save time and money and to avoid reporting false results. To determine differences in the slide review rates of 3 widely used automated hematologic analyzers, the Unicel DxH 800 (Beckman Coulter Inc, Fullerton, California), ADVIA 2120i (Siemens Diagnostics, Tarrytown, New York), and XE 2100 (Sysmex, Kobe, Japan), using International Consensus Group for Hematology Review guidelines. A total of 1485 samples were tested, and 300 were manually reviewed. Slide review rates, sensitivity, specificity, and false-positive and false-negative rates were estimated using consensus group rules and compared using χ(2) tests, Fisher exact tests, or generalized estimating equations. Unicel DxH 800, ADVIA 2120i, and XE 2100 showed 22.8%, 20.2%, and 28.6% slide review rates; 14.3%, 14.3%, and 9.7% false-negative rates; and 13.7, 11.3%, and 17.3% false-positive rates, respectively. All analyzers showed significantly higher false-negative rates than that of the consensus group (2.9%). False-negative rates were higher than the recommended levels. Among 3 automated hematologic analyzers, XE 2100 showed the highest rate of slide review. Because the present study clearly shows that the slide review rates have distinct characteristics among the studied analyzers, each individual laboratory should consider selecting the most appropriate analyzer according to clinical characteristics. Analyzers with high sensitivity may be advantageous in outpatient settings for screening patients, whereas analyzers with high specificity may be beneficial in inpatient settings for efficient patient care.

  8. 13 CFR 120.800 - The purpose of the 504 program.

    Science.gov (United States)

    2010-01-01

    ..., and stimulate growth, expansion, and modernization of small businesses. ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false The purpose of the 504 program. 120.800 Section 120.800 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS...

  9. A 800 kV compact peaking capacitor for nanosecond generator.

    Science.gov (United States)

    Jia, Wei; Chen, Zhiqiang; Tang, Junping; Chen, Weiqing; Guo, Fan; Sun, Fengrong; Li, Junna; Qiu, Aici

    2014-09-01

    An extremely compact high voltage peaking capacitor is developed. The capacitor has a pancake structure with a diameter of 315 mm, a thickness of 59 mm, and a mass of 6.1 kg. The novel structural design endows the capacitor with a better mechanical stability and reliability under hundreds of kilovolts pulse voltage and an inner gas pressure of more than 1.5 MPa. The theoretical value of the capacitor self-inductance is near to 17 nH. Proved by series of electrical experiments, the capacitor can endure a high-voltage pulse with a rise time of about 20 ns, a half-width duration of around 25 ns, and an amplitude of up to 800 kV in a single shot model. When the capacitor was used in an electromagnetic pulse simulator as a peaking capacitor, the rise time of the voltage pulse can be reduced from 20 ns to less than 3 ns. The practical value of the capacitor's inductance deduced from the experimental date is no more than 25 nH.

  10. 22 CFR 208.800 - What are the causes for debarment?

    Science.gov (United States)

    2010-04-01

    ... accordance with the terms of one or more public agreements or transactions; (2) A history of failure to... 22 Foreign Relations 1 2010-04-01 2010-04-01 false What are the causes for debarment? 208.800 Section 208.800 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT GOVERNMENTWIDE DEBARMENT AND...

  11. 7 CFR 800.17 - Special inspection and weighing requirements for sacked export grain.

    Science.gov (United States)

    2010-01-01

    ... sacked export grain. 800.17 Section 800.17 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD ADMINISTRATION (FEDERAL GRAIN INSPECTION SERVICE... Requirements § 800.17 Special inspection and weighing requirements for sacked export grain. (a) General...

  12. On Eddy current examination (ECE) of Incoloy 800 SG tube using OD encircling and ID bobbin coil

    International Nuclear Information System (INIS)

    Kapoor, K.; Sunder Krishna, K.; Bakshu, S.A.

    2015-01-01

    The purpose of this paper is to present and compare the results of ECE carried out on steam generator tubes from OD side and ID side. During the manufacturing of the tubes Eddy current testing is being carried out using OD encircling probe as per ASTM E 571. Here the purpose of the test is to capture the manufacturing defects. The parameters of the test are optimized to achieve best sensitivity to this requirement. These tubes are then installed in the steam generator and once again ECE is carried out during installation (pre-service inspection-PSI) and during in-service inspection (ISI) by using ID bobbin coil. These tests are carried out as per ASME section V article 8 appendix 1. Here the purpose of the test is to detect wall thinning, dent, pits etc due to operation and to locate these defects (OD side or ID side). Here the operating parameters are optimized for phase separation of defects from OD and ID. These parameters are quite different from those used during the manufacturing ECE. Interpretation of the signals detected in PSI/ISI in must be done with care to correlate with defect indications detected during manufacturing. In the present study, tubes with certain manufacturing defects, detected with OD encircling test were subjected to ID bobbin coil examination. Also certain tubes with signal picked up during test from ID were examined by using the OD encircling probe. This comparison of the results provides a clear picture about the sensitivity and deficiency of the either type of test. (author)

  13. Stress corrosion cracking of steam generator tube and primary pipe in PWR type nuclear power plants

    International Nuclear Information System (INIS)

    Zhang Weiguo; Gao Fengqin; Zhou Hongyi

    1992-03-01

    The behavior of stress corrosion cracking (SCC) was studied by slow strain rate test (SSRT), constant load test (CLT) and low frequency cyclic loading test (LFCLT). The purpose of these tests is to get the test data for evaluating the integrity of pressurized boundary of pipes in Qinshan and Guangdong nuclear power plants (NPPs). Tested materials are 316 nuclear grade stainless steel (SS) for primary pipes in welded heat affected zone (WHAZ) and tubes of heat transfer, such as Incoloy-800, Inconel-600 and 321 SS which are used for steam generator in PWR NPPs. The effects of material metallurgy, shot peening treatment, tensile load, strain rate, cyclic load and water chemistry on the behavior of SCC were considered

  14. A study of small leaks of water into sodium-heated steam generators - self evolution and wastage

    International Nuclear Information System (INIS)

    Feburie, V.; Desmas, T.; Cronier, B.

    1987-01-01

    MICROMEGAS is a fully automatic test loop operating without human surveillance. It is utilized to study small leaks of water into sodium, specially the spontaneous development of a fatigue-induced crack in a tube of Incoloy 800 (dormant period, microleak, self-evolution) and the wastage of neighbouring tubes. The thermohydraulic conditions of the last tests corresponded to the economizer zone of SUPER-PHENIX steam generators, at 350 0 C. These tests were compared with those which had been done before, corresponding to the superheating zone, at 490 0 C. The main result was that the microleak phase was longer and the self-evolution slower at 350 0 C than at 490 0 C. (author)

  15. Stress corrosion cracking of steam generator tube and primary pipe in PWR type nuclear power plants

    International Nuclear Information System (INIS)

    Zhang Weiguo; Gao Fengqin; Zhou Hongyi

    1993-01-01

    The behavior of stress corrosion cracking (SCC) is studied by slow strain rate test (SSRT), constant load test (CLT) and low frequency cyclic loading test (LFCLT). The purpose of these tests is to get the test data for evaluating the integrity of pressurized boundary of pipes in Qinshan and Guangdong nuclear power plants. Tested materials are 316 nuclear grade stainless steel (SS) for primary pipes in welded heat affected zone (WHAZ) and steam generator tubes, such as Incoloy-800, Inconel-600, Inconel-690 and 321 SS which are used for steam generator in PWR. The effects of material metallurgy, shot-peening treatment, tensile load, strain rate, cyclic load and water chemistry on the behavior of SCC are investigated

  16. 7 CFR 800.83 - Sampling provisions by kind of movement.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Sampling provisions by kind of movement. 800.83... REGULATIONS Inspection Methods and Procedures § 800.83 Sampling provisions by kind of movement. (a) Export cargo movements—(1) Bulk grain. Except as may be approved by the Administrator on a shipment-by-shipment...

  17. 49 CFR 800.28 - Delegation to the Chief Financial Officer.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Delegation to the Chief Financial Officer. 800.28... Authority to Staff Members § 800.28 Delegation to the Chief Financial Officer. The Board delegates to the Chief Financial Officer the authority to settle claims for money damages of $2,500 or less against the...

  18. Hydrogen permeation behavior through F82H at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, S.; Katayama, K.; Shimozori, M.; Fukada, S. [Interdisciplinary Graduate School of Engineering Science, Kyushu University, Kyushu (Japan); Ushida, H. [Energy Science and Engineering, Faculty of Engineering, Kyushu University, Kyushu (Japan); Nishikawa, M. [Malaysia-Japan International Institute of Technology, UTM, Kuala Lumpur (Malaysia)

    2015-03-15

    F82H is a primary candidate of structural material and coolant pipe material in a blanket of a fusion reactor. Understanding tritium permeation behavior through F82H is important. In a normal operation of a fusion reactor, the temperature of F82H will be controlled below 550 C. degrees because it is considered that F82H can be used up to 30,000 hours at 550 C. degrees. However, it is necessary to assume the situation where F82H is heated over 550 C. degrees in a severe accident. In this study, hydrogen permeation behavior through F82H was investigated in the temperature range from 500 to 800 C. degrees. In some cases, water vapor was added in a sample gas to investigate an effect of water vapor on hydrogen permeation. The permeability of hydrogen in the temperature range from 500 to 700 C. degrees agreed well with the permeability reported by E. Serra et al. The degradation of the permeability by water vapor was not observed. After the hydrogen permeation reached in a steady state at 700 C. degrees, the F82H sample was heated to 800 C. degrees. The permeability of hydrogen through F82H sample which was once heated up to 800 C. degrees was lower than that of the original one. (authors)

  19. Effect of different ions on the anodic behaviour of alloy 800 chloride solutions at high temperature

    International Nuclear Information System (INIS)

    Lafont, C.J.; Alvarez, M.G.

    1993-01-01

    The anodic behaviour and passivity breakdown of alloy 800 in sodium bicarbonate and sodium phosphate aqueous solutions were studied in the temperature range from 100 degrees C to 280 degrees C by means of electrochemical techniques. The effect of phosphate or bicarbonate additions on the pitting susceptibility and pitting morphology of the alloy in chloride solutions was also examined. Experiments were performed in the following solutions: 0.1M NaHCO 3 , at 100 degrees C, 200 degrees C, 280 degrees C; 0.06M NaH 2 PO 4 + 0.04M Na 2 HPO 4 , at 100 degrees C, 200 degrees C and 280 degrees C, and 0.1M NaCl with different additions of bicarbonate ion (0.02M, 0.05M and 0.1M) and phosphate ion (0.01M, 0.05M and 0.1M) at 100 degrees C and 280 degrees C. The anodic polarization curves of alloy 800 in deaerated 0.1M NaHCO 3 and 0.06M NaH 2 PO 4 + 0.04M Na 2 HPO 4 solutions exhibited a similar shape at all the tested temperatures. No localized or generalized corrosion was detected on the metallic surface after polarization. The results obtained in chloride plus bicarbonate and chloride plus phosphate mixtures showed that the pitting potential of alloy 800 in chloride solutions was increased by the presence of bicarbonate or phosphate ions. In those solutions where the inhibitor concentration in the mixture is equal or higher than the chloride concentration , the behaviour of the alloy is similar to the one observed in the absence of chlorides. Changes in pitting morphology were found in phosphate containing solutions, while the pits found in bicarbonate containing solutions were similar to those formed in pure chloride solutions. (author). 3 refs., 4 figs

  20. Qualification of Alloy 800 for sodium heated steam generators

    International Nuclear Information System (INIS)

    Duke, J.M.; Sessions, C.E.; Ray, W.E.

    1976-01-01

    A reference specification of Alloy 800 for use in LMFBR steam generators is defined considering waterside corrosion, weldability and mechanical properties. Additional mechanical test data are being generated to support ASME Code acceptance. Candidate weld filler metals were assessed for use in subsequent weld process development. Progress on resolving technical concerns related to the role of tertiary creep identified the impact of test conditions and gamma prime strengthening in determining the creep behavior of Alloy 800

  1. Pharmacokinetics and pharmacodynamics of SCT800, a new recombinant FVIII, in hemophilia A mice

    Science.gov (United States)

    Gu, Ruo-lan; Liu, Liang; Xie, Liang-zhi; Gai, Wen-lin; Cao, Si-shuo; Meng, Zhi-yun; Gan, Hui; Wu, Zhuo-na; Li, Jian; Zheng, Ying; Zhu, Xiao-xia; Dou, Gui-fang

    2016-01-01

    Aim: SCT800 is a new third-generation recombinant FVIII agent that is undergoing promising preclinical study. This study aimed to investigate the pharmacokinetic and pharmacodynamic profiles of SCT800 in hemophilia A mice. Methods: After hemophilia A mice were intravenously injected with single dose of SCT800 (80, 180, and 280 IU/kg) or the commercially available product Xyntha (280 IU/kg), pharmacokinetics profiles were evaluated based on measuring plasma FVIII: C. For pharmacodynamics study, dose-response curves of SCT800 and Xyntha (1–200 IU/kg) were constructed using a tail bleeding model monitoring both bleeding time and blood loss. Results: Pharmacokinetics profile analysis showed a dose independency of SCT800 ranging from 80 to 280 IU/kg and comparable pharmacokinetic profiles between SCT800 and Xyntha at the doses tested. Pharmacodynamics study revealed comparable ED50 values of SCT800 and Xyntha in the tail bleeding model: 14.78 and 15.81 IU/kg for bleeding time, respectively; 13.50 and 13.58 IU/kg for blood loss, respectively. Moreover, at the doses tested, the accompanying dose-related safety evaluation in the tail bleeding model showed lower hypercoagulable tendency and wider dosage range potential for SCT800 than Xyntha. Conclusion: In hemophilia A mice, SCT800 shows comparable pharmacokinetics and pharmacodynamics to Xyntha at the doses tested, and possibly with better safety properties. PMID:26806305

  2. H0 precessor computer code

    International Nuclear Information System (INIS)

    van Dyck, O.B.; Floyd, R.A.

    1981-05-01

    A spin precessor using H - to H 0 stripping, followed by small precession magnets, has been developed for the LAMPF 800-MeV polarized H - beam. The performance of the system was studied with the computer code documented in this report. The report starts from the fundamental physics of a system of spins with hyperfine coupling in a magnetic field and contains many examples of beam behavior as calculated by the program

  3. JAZZ-800信号处理器

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Miranda推出的JAZZ-800是一个仅1RU的单/双通道通用信号处理器,它结合高性能的信号处理功能和便捷的操作控制,提供了上/下/交叉/ARC和高/标清变换功能,以及数/模之间的转换功能,适合多信号的工作环境。JAZZ-800配备带功能菜单和视频监视的本地控制面板,具备噪音屏蔽的高/标清画面显示,

  4. The Effects of Temperature, Humidity and Aircraft Fluid Exposure on T800H/3900-2 Composites Bonded with AF-555M Adhesive

    Science.gov (United States)

    Miner, Gilda A.; Hou, Tan-Hung; Lowther, Sharon E.; Thibeault, Sheila A.; Connell, John W.; Blasini, Sheila Roman

    2010-01-01

    Fiber reinforced resin matrix composites and structural adhesives have found increased usage on commercial and military aircraft in recent years. Due to the lack of service history of these relatively new material systems, their long-term aging performance has not been well established. In this study, single lap shear specimens (SLS) were fabricated by secondary bonding of Scotch-Weld(TradeMark) AF-555M between pre-cured adherends comprised of T800H/3900-2 uni-directional laminates. The adherends were co-cured with wet peel-ply for surface preparation. Each bond-line of the SLS specimen was measured to determine thickness and inspected visually using an optical microscope for voids. A three-year environmental aging plan for the SLS specimens at 82 C (180 F) and 85% relative humidity was initiated. SLS strengths were measured for both controls and aged specimens at room temperature and 82 C. The effect of this exposure on lap shear strength and failure modes to date is reported. In addition, the effects of water, saline water, deicing fluid, JP-5 jet fuel and hydraulic fluid on both the composite material and the adhesive bonds were investigated. The up to date results on the effects of these exposures will be discussed.

  5. 47 CFR 80.303 - Watch on 156.800 MHz (Channel 16).

    Science.gov (United States)

    2010-10-01

    ... Section 80.303 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Coast Station Safety... maintain a safety watch on the frequency 156.800 MHz except when transmitting on 156.800 MHz. (b) A coast...

  6. Processing results of 1,800 gallons of mercury and radioactively contaminated mixed waste rinse solution

    International Nuclear Information System (INIS)

    Thiesen, B.P.

    1993-01-01

    The mercury-contaminated rinse solution (INEL waste ID number-sign 123; File 8 waste) was successfully treated at the Idaho National Engineering Laboratory (INEL). This waste was generated during the decontamination of the Heat Transfer Reactor Experiment 3 (HTRE-3) reactor shield tank. Approximately 1,800 gal of waste was generated and was placed into 33 drums. Each drum contained precipitated sludge material ranging from 1--10 in. in depth, with the average depth of about 2.5 in. The pH of each drum varied from 3--11. The bulk liquid waste had a mercury level of 7.0 mg/l, which exceeded the Resource Conservation and Recovery Act (RCRA) limit of 0.2 mg/l. The average liquid bulk radioactivity was about 2.1 pCi/ml, while the average sludge contamination was about 13,800 pci/g. Treatment of the waste required separation of the liquid from the sludge, filtration, pH adjustment, and ion exchange. Because of difficulties in processing, three trials were required to reduce the mercury levels to below the RCRA limit. In the first trial, insufficient filtration of the waste allowed solid particulate produced during pH adjustment to enter into the ion exchange columns and ultimately the waste storage tank. In the second trial, the waste was filtered down to 0.1 μ to remove all solid mercury compounds. However, before filtration could take place, a solid mercury complex dissolved and mercury levels exceeded the RCRA limit after filtration. In the third trial, the waste was filtered through 0.3-A filters and then passed through the S-920 resin to remove the dissolved mercury. The resulting solut

  7. The determination of 800 to 30 μg lead(II) by potentiometric titration with molybdate

    International Nuclear Information System (INIS)

    Campiglio, A.

    1985-01-01

    The determination of 800 to 30 μg Pb(II) by potentiometric titration with molybdate by using a lead(II)-selective electrode was investigated. Under suitable conditions, 800 to 300 μg Pb(II) in aqueous solution by automatic or manual titration with 4x10 -3 M molybdate can be determined with an accuracy of +-0.57% and +-0.45% and a precision of +-0.43% and 0.30% (standard deviation = 0.25% and 0.17%, resp.). For determining amounts of Pb(II) below 300 μg, a 2x10 -3 M molybdate solution has to be used. Although 300 to 100μg Pb(II) are determinable again in water with satisfactory results, the titration in 40% ethanol is however more reliable: in this medium, amounts of 300 to 30μg Pb(II) can be determined with an accuracy of +-1% and a precision of +-2% (standard deviation from 20 titrations of 100μg Pb(II)=0.60%). The titration of 300-800μg Pb(II) in water and of 30-300μg Pb(II) in 40% ethanol is also possible in 0.1 M NaNO 3 sub- snd 0.1 M NaClO 4 sub- medium and can be used in the lead determination in organic compounds after mineralization with HNO 3 sub-HClO 4 sub-H 2 O 2 . (Author)

  8. 49 CFR 219.800 - Annual reports.

    Science.gov (United States)

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Annual Report § 219.800 Annual reports. (a) Each... also use the electronic version of the MIS form provided by the DOT. The Administrator may designate... submission to FRA. For information on where to submit MIS forms and for the electronic version of the form...

  9. Laser spectroscopy of relativistic beams of H- and H

    International Nuclear Information System (INIS)

    Smith, W.W.; Tang, C.Y.; Harris, P.G.; Mohagheghi, A.H.; Bryant, H.C.; Reeder, R.A.; Toutounchi, H.; Sharifian, H.

    1989-01-01

    Laser spectroscopy on near-light velocity H- ions and H atoms has been carried out at the Los Alamos Meson Physics Facility using a variety of fixed frequency lasers intersecting accelerated beams at variable angles. Beam energies up to 800 MeV (v/c) = 0.84 make possible an unusually wide tuning range at modestly high resolution. A dedicated beam line, the High Resolution Atomic Beam (HIRAB), also makes possible Stark effect and field ionization studies in the multi-megavolt/cm range. Preliminary results on multiphoton detachment of fast H-ions using a pulsed CO 2 laser focussed to ∼10 11 W/cm 2 over a factor 10 photon energy range (CM frame) are presented in this paper

  10. 78 FR 28749 - Private Land Mobile Radio Stations Below 800 MHz

    Science.gov (United States)

    2013-05-16

    ... these proposals, with the exception of those issues relating to Wireless Medical Telemetry Services... accomplished in the PLMR bands below 800 MHz. A trunked radio system employs technology that can search two or... prohibited by Sec. 1.935). We also take this opportunity to correct the 800 MHz band trunking rules to set...

  11. Stark absorption spectroscopy on the carotenoids bound to B800-820 and B800-850 type LH2 complexes from a purple photosynthetic bacterium, Phaeospirillum molischianum strain DSM120.

    Science.gov (United States)

    Horibe, Tomoko; Qian, Pu; Hunter, C Neil; Hashimoto, Hideki

    2015-04-15

    Stark absorption spectroscopy was applied to clarify the structural differences between carotenoids bound to the B800-820 and B800-850 LH2 complexes from a purple photosynthetic bacterium Phaeospirillum (Phs.) molischianum DSM120. The former complex is produced when the bacteria are grown under stressed conditions of low temperature and dim light. These two LH2 complexes bind carotenoids with similar composition, 10% lycopene and 80% rhodopin, each with the same number of conjugated CC double bonds (n=11). Quantitative classical and semi-quantum chemical analyses of Stark absorption spectra recorded in the carotenoid absorption region reveal that the absolute values of the difference dipole moments |Δμ| have substantial differences (2 [D/f]) for carotenoids bound to either B800-820 or B800-850 complexes. The origin of this striking difference in the |Δμ| values was analyzed using the X-ray crystal structure of the B800-850 LH2 complex from Phs. molischianum DSM119. Semi-empirical molecular orbital calculations predict structural deformations of the major carotenoid, rhodopin, bound within the B800-820 complex. We propose that simultaneous rotations around neighboring CC and CC bonds account for the differences in the 2 [D/f] of the |Δμ| value. The plausible position of the rotation is postulated to be located around C21-C24 bonds of rhodopin. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Low concentration NP preoxidation condition for PWR decontamination

    International Nuclear Information System (INIS)

    Huang Fuduan; Yu Degui; Lu Jingju; Ding Dejun; Zhao Yukun

    1991-02-01

    To use preoxidation condition with low concentration NP (nitric acid permanganate) instead of conventional high concentration AP (alkline permanganate ) for PWR oxidation decontamination (POD) was summarized. Experiments including three parts have been performed. The defilming performance and decontamination factor of preoxidation with low concentration NP, which is 100, 10 times lower than that of AP are better than that with high concentration AP. The reason has been studied with the aid of prefilmed specimens of corrosion potential measuring in NP solution and chromium release in NP and AP solutions. The behaviour of alloy 13 prefilmed specimen in NP preoxidation solution is different from 18-8 ss and Incoloy 800. In the low acidity, the corrosion potential moves toward positive direction as the acidity becomes high

  13. Effect of fission product interactions on the corrosion and mechanical properties of HTGR alloys

    International Nuclear Information System (INIS)

    Aronson, S.; Chow, J.G.Y.; Soo, P.; Friedlander, M.

    1978-01-01

    Preliminary experiments have been carried out to determine how fission product interactions may influence the mechanical integrity of reference HTGR structural metals. In this work Type 304 stainless steel, Incoloy 800 and Hastelloy X were heated to 550 to 650 0 C in the presence of CsI. It was found that no corrosion of the alloys occurred unless air or oxygen was also present. A mechanism for the observed behavior is proposed. A description is also given of some long term exposures of HTGR materials to more prototypic, low concentrations of I 2 , Te 2 and CsI in the presence of low partial pressures of O 2 . These samples are scheduled for mechanical bend tests after exposure to determine the degree of embrittlement

  14. Evaluation of the Control Rod Super Alloy Material of HTR-PM

    International Nuclear Information System (INIS)

    Li Pengjun; Yan He; Diao Xingzhong

    2014-01-01

    The control rod drive mechanism (CRDM) system is served as the first reactivity control and shutdown system for the high temperature reactor pebble-bed module (HTR-PM) in Shandong, China. And the control rod, which is pulled up and down by a chain sprocket mechanism of CRDM to realize reactivity control, compensation and shutdown, has to be durable under temperature as high as 550℃ for a long time. Thus the material persistent strength under high temperature is quite important for the reliability of the CRDM. In this paper, a review on material selection of control rod of high temperature gas cooled reactors, including AVR and THTR-300 in Germany, HTTR in Japan, PBMR in South Africa and Dragon in Britain, was summarized. The major parameters of two kinds of high temperature alloy, incoloy 800H and alloy 625, were compared and discussed. According to the ASME NH volume, a design criterion for the control rod was established and applied in the analysis of the chain by using finite element method. The numerical simulations showed that the chain made of alloy 625 could meet the condition and work for a long time under high temperature. (author)

  15. The phase system Fe-Ir-S at 1100, 1000 and 800 degree C

    DEFF Research Database (Denmark)

    Makovicky, Emil; Karup-Møller, Sven

    1999-01-01

    Phase relations in the dry condensed Fe-Ir-S system were determined at 1100, 1000 and 800 degrees C. Orientational runs were performed at 500 degrees C. Between 1100 and 800 degrees C, the system comprises five sulphides and an uninterrupted field of gamma(Fe, Ir). Fe1-xS dissolves 5.8 at.% Ir...... at 1100 degrees C, 3.4 at.% Ir at 1000 degrees C and 1.0 at.% Ir at 800 degrees C. The solubility of Fe in Ir2S3, IrS2 and IrSsimilar to 3 increases with decreasing temperature, reaching 2.5 at.% in the latter two sulphides at 800 degrees C. Thiospinel 'FeIr2S4' is nonstoichiometric, from Fe22.3Ir19.8S58...

  16. 奥林巴斯Stylus 800 Digital数码相机

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    这一款高达800万像素的最新数码相机,它外形小巧,在经典的μ mini DIGITAL基础上作了一些调整,使之操作手感更强。DIGITAL 800采用1/1.8英寸,800万有效像素CCD,3倍光学变焦,相当于35mm相机的38~114mm,属于一般家用的配置。2.5英寸的液晶显示屏,分辨率达到21.5万像素。采用xD卡,可充式锂电池。

  17. Application of the ASME-code-case N 47 to a typical thickwalled HTR-component made of Incoloy 800

    International Nuclear Information System (INIS)

    Kemter, F.; Schmidt, A.

    Several components of the HTR-plant are exposed to temperatures beyond 500 0 C, i.e. within the high-temperature range. The service life of those components is not only limited by fatigue damage but also mainly by creep damage and accumulated inelastic strain. These can be conservatively estimated according to the ASME-Code (high temperature part CC N47) by means of the results of elastic calculations, yet this simplified method to provide evidence often leads to calculated overloads such as the present case of the live steam collector of the steam generator of a HTR. For providing the evidence that the actual loads of the component are within permissible limits, comprehensive inelastic analyses have to be referred to in such a case. The two-dimensional inelastic analysis which is reported here in detail shows that the creep and fatigue failure as well as the inelastic extensions of the live steam collectors accumulated during the service time are below the permissible limit stated in the ASME-Code and failure of those components while used in the reactor can this be excluded. (orig.) [de

  18. Phase diagram of the Fe-Sn-Zr system at 800 °C

    International Nuclear Information System (INIS)

    Nieva, N.; Corvalán, C.; Jiménez, M.J.; Gómez, A.; Arreguez, C.; Joubert, J.-M.; Arias, D.

    2017-01-01

    New experimental results on the Fe-Sn-Zr phase diagram at 800 °C are presented, particularly in the central, Fe rich and Sn rich regions of the Gibbs triangle. Seven ternary alloys were designed, produced and examined by different techniques: optical and scanning electron microscopy, semi-quantitative microanalysis, quantitative microanalysis and X-ray diffraction. The results of this work and previous experimental data were used to determine the phase diagram section at 800 °C which contains at least five ternary compounds: Fe 6 Sn 6 Zr, Y, X′, θ and C36. - Highlights: •A phase diagram of Fe-Sn-Zr system at 800 °C is proposed. •The isothermal section of Fe-Sn-Zr system at 800 °C and that at 900 °C determined previously allow reliable extrapolations at low temperatures. •The study at different temperatures (900 °C and 800 °C in this case) is highly desirable because it allows the separation between enthalpic and entropic effects in a future Calphad modelling.

  19. Phase diagram of the Fe-Sn-Zr system at 800 °C

    Energy Technology Data Exchange (ETDEWEB)

    Nieva, N. [Laboratorio de Física del Sólido, Departamento de Física, Facultad de Ciencias Exactas y Tecnología, Universidad Nacional de Tucumán (Argentina); Corvalán, C., E-mail: corvalan@cnea.gov.ar [Gerencia de Materiales, Comisión Nacional de Energía Atómica Argentina (CNEA), Universidad Nacional de Tres de Febrero, Argentina, CONICET, Consejo Nacional de Ciencia y Técnica (Argentina); Jiménez, M.J. [IFISUR, CONICET, Departamento de Física, Universidad Nacional del Sur, Bahía Blanca (Argentina); Gómez, A. [Grupo LMFAE – PPFAE, Centro Atómico Ezeiza, Comisión Nacional de Energía Atómica (Argentina); Arreguez, C. [Laboratorio de Física del Sólido, Departamento de Física, Facultad de Ciencias Exactas y Tecnología, Universidad Nacional de Tucumán (Argentina); Joubert, J.-M. [Chimie Métallurgique des Terres Rares (CMTR), Institut de Chimie et des Matériaux Paris-Est (ICMPE), CNRS, Université Paris-Est Créteil, 2-8 rue Henri Dunant, 94320 Thiais Cedex (France); Arias, D. [Instituto de Tecnología J. Sabato, Universidad Nacional de San Martín-CNEA (Argentina)

    2017-04-15

    New experimental results on the Fe-Sn-Zr phase diagram at 800 °C are presented, particularly in the central, Fe rich and Sn rich regions of the Gibbs triangle. Seven ternary alloys were designed, produced and examined by different techniques: optical and scanning electron microscopy, semi-quantitative microanalysis, quantitative microanalysis and X-ray diffraction. The results of this work and previous experimental data were used to determine the phase diagram section at 800 °C which contains at least five ternary compounds: Fe{sub 6}Sn{sub 6}Zr, Y, X′, θ and C36. - Highlights: •A phase diagram of Fe-Sn-Zr system at 800 °C is proposed. •The isothermal section of Fe-Sn-Zr system at 800 °C and that at 900 °C determined previously allow reliable extrapolations at low temperatures. •The study at different temperatures (900 °C and 800 °C in this case) is highly desirable because it allows the separation between enthalpic and entropic effects in a future Calphad modelling.

  20. R I 800. A new cobalt-60 sealed source design

    International Nuclear Information System (INIS)

    Freijo, Jose L.; Gomez, Gonzalo

    2006-01-01

    The consolidation of the international market of Co-60 sources and the perspective of its growth has encouraged the development of new types of sealed sources. The model R I 800 is designed for activities up to 65 kCi and allows a large spectrum of capsules with different specific activities. During three years Dioxitek developed the process of fabrication and qualifications to comply the design requirements and succeeded in the product approval. Today, the initial lot at an industrial scale of R I 800 sources is under fabrication and a first partial shipment of 100 kCi to the United Kingdom was successfully carried out at the end of October 2005. The whole lot is for export. Due to the versatility of the R I 800 sealed sources it was possible to use as raw material 1 MCi of Co-60 imported from Russia, irradiated in Leningrad nuclear power plant. (author) [es

  1. IND-directed safety and biodistribution study of intravenously injected cetuximab-IRDye800 in cynomolgus macaques.

    Science.gov (United States)

    Zinn, Kurt R; Korb, Melissa; Samuel, Sharon; Warram, Jason M; Dion, David; Killingsworth, Cheryl; Fan, Jinda; Schoeb, Trenton; Strong, Theresa V; Rosenthal, Eben L

    2015-02-01

    The use of receptor-targeted antibodies conjugated to fluorophores is actively being explored for real-time imaging of disease states; however, the toxicity of the bioconjugate has not been assessed in non-human primates. To this end, the in vivo toxicity and pharmacokinetics of IRDye800 conjugated to cetuximab (cetuximab-IRDye800; 21 mg/kg; equivalent to 250 mg/m(2) human dose) were assessed in male cynomolgus monkeys over 15 days following intravenous injection and compared with an unlabeled cetuximab-dosed control group. Cetuximab-IRDye800 was well tolerated. There were no infusion reactions, adverse clinical signs, mortality, weight loss, or clinical histopathology findings. The plasma half-life for the cetuximab-IRDye800 and cetuximab groups was equivalent (2.5 days). The total recovered cetuximab-IRDye800 in all tissues at study termination was estimated to be 12 % of the total dose. Both cetuximab-IRDye800 and cetuximab groups showed increased QTc after dosing. The QTc for the cetuximab-dosed group returned to baseline by day 15, while the QTc of the cetuximab-IRDye800 remained elevated compared to baseline. IRDye800 in low molar ratios does not significantly impact cetuximab half-life or result in organ toxicity. These studies support careful cardiac monitoring (ECG) for human studies using fluorescent dyes.

  2. Effect of coatings on long term behaviour of a commercial stainless steel for solid oxide electrolyser cell interconnect application in H2/H2O atmosphere

    International Nuclear Information System (INIS)

    Ardigo, M.R.; Popa, I.; Chevalier, S.; Girardon, P.; Perry, F.; Laucournet, R.; Brevet, A.; Desgranges, C.

    2014-01-01

    K41X (AISI 441) stainless steel evidenced a high electrical conductivity after 3000 h ageing in H 2 /H 2 O side when used as interconnect for solid oxide electrolyser cells (SOEC) working at 800 C. Perovskite (La 1-x Sr x MnO 3-δ ) and spinel (Co 3 O 4 ) oxides coatings were applied on the surface of the ferritic steel for ageing at 800 C for 3000 h. Both coatings improved the behaviour of the steel and give interesting opportunities to use the K41X steel as interconnect for hydrogen production via high temperature steam electrolysis. Co 3 O 4 reduced into Co leading to a very good Area Specific Resistance (ASR) parameter, 0.038 Ωcm 2 . Despite a good ASR (0.06 Ωcm 2 ), La 1-x Sr x MnO 3-δ was less promising because it partially decomposed into MnO and La 2 O 3 during ageing in H 2 /H 2 O atmosphere. (authors)

  3. On Light-Induced Photoconversion of B800 Bacteriochlorophylls in the LH2 Antenna of the Purple Sulfur Bacterium Allochromatium vinosum.

    Science.gov (United States)

    Kell, Adam; Jassas, Mahboobe; Hacking, Kirsty; Cogdell, Richard J; Jankowiak, Ryszard

    2017-11-02

    The B800-850 LH2 antenna from the photosynthetic purple sulfur bacterium Allochromatium vinosum exhibits an unusual spectral splitting of the B800 absorption band; i.e., two bands are well-resolved at 5 K with maxima at 805 nm (B800 R ) and 792 nm (B800 B ). To provide more insight into the nature of the B800 bacteriochlorophyll (BChl) a molecules, high-resolution hole-burning (HB) spectroscopy is employed. Both white light illumination and selective laser excitations into B800 R or B800 B lead to B800 R → B800 B phototransformation. Selective excitation into B800 B leads to uncorrelated excitation energy transfer (EET) to B800 R and subsequent B800 R → B800 B phototransformation. The B800 B → B800 R EET time is 0.9 ± 0.1 ps. Excitation at 808.4 nm (into the low-energy side of B800 R ) shows that the lower limit of B800 R → B850 EET is about 2 ps, as the B800 R → B800 B phototransformation process could contribute to the corresponding zero-phonon hole width. The phototransformation of B800 R leads to a ∼ 200 cm -1 average blue-shift of transition energies, i.e., B800 R changes into B800 B . We argue that it is unlikely that B800-B850 excitonic interactions give rise to a splitting of the B800 band. We propose that the latter is caused by different protein conformations that can lead to both strong or weak hydrogen bond(s) between B800 pigments and the protein scaffolding. Temperature-dependent absorption spectra of B800, which revealed a well-defined isosbestic point, support a two-site model, likely with strongly and weakly hydrogen-bonded B800 BChls. Thus, BChls contributing to B800 R and B800 B could differ in the position of the proton in the BChl carbonyl-protein hydrogen bond, i.e., proton dynamics along the hydrogen bond may well be the major mechanism of this phototransformation. However, the effective tunneling mass is likely larger than the proton mass.

  4. 47 CFR 22.970 - Unacceptable interference to part 90 non-cellular 800 MHz licensees from cellular radiotelephone...

    Science.gov (United States)

    2010-10-01

    ...-cellular 800 MHz licensees from cellular radiotelephone or part 90-800 MHz cellular systems. 22.970 Section... MOBILE SERVICES Cellular Radiotelephone Service § 22.970 Unacceptable interference to part 90 non-cellular 800 MHz licensees from cellular radiotelephone or part 90-800 MHz cellular systems. (a) Definition...

  5. Temporal and spatial variability of rainfall pH

    Science.gov (United States)

    Richard G. Semonin

    1977-01-01

    The distribution of average rainwater pH over an area of 1,800 km² containing 81 collectors was determined from 25 storm events. The areal average of the data was pH 4.9, with a range of values from 4.3 to 6.8. A single storm event was studied to determine the change of pH as a function of time. The initial rain was pH 7.1, decreasing to 4.1. An excellent...

  6. 7 CFR 800.147 - Maintenance and retention of records on delegations, designations, contracts, and approval of...

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Maintenance and retention of records on delegations, designations, contracts, and approval of scale testing organizations. 800.147 Section 800.147 Agriculture... and Forms (general) § 800.147 Maintenance and retention of records on delegations, designations...

  7. High Temperature Fuel Cladding Chemical Interactions Between TRIGA Fuels and 304 Stainless Steel

    Energy Technology Data Exchange (ETDEWEB)

    Perez, Emmanuel [Idaho National Lab. (INL), Idaho Falls, ID (United States); Keiser, Jr., Dennis D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Forsmann, Bryan [Boise State Univ., ID (United States); Janney, Dawn E. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Henley, Jody [Idaho National Lab. (INL), Idaho Falls, ID (United States); Woolstenhulme, Eric C. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-02-01

    High-temperature fuel-cladding chemical interactions (FCCI) between TRIGA (Training, Research, Isotopes, General Atomics) fuel elements and the 304 stainless steel (304SS) are of interest to develop an understanding of the fuel behavior during transient reactor scenarios. TRIGA fuels are composed of uranium (U) particles dispersed in a zirconium-hydride (Zr-H) matrix. In reactor, the fuel is encased in 304-stainless-steel (304SS) or Incoloy 800 clad tubes. At high temperatures, the fuel can readily interact with the cladding, resulting in FCCI. A number of FCCI can take place in this system. Interactions can be expected between the cladding and the Zr-H matrix, and/or between the cladding and the U-particles. Other interactions may be expected between the Zr-H matrix and the U-particles. Furthermore, the fuel contains erbium-oxide (Er-O) additions. Interactions can also be expected between the Er-O, the cladding, the Zr-H and the U-particles. The overall result is that very complex interactions may take place as a result of fuel and cladding exposures to high temperatures. This report discusses the characterization of the baseline fuel microstructure in the as-received state (prior to exposure to high temperature), characterization of the fuel after annealing at 950C for 24 hours and the results from diffusion couple experiments carries out at 1000C for 5 and 24 hours. Characterization was carried out via scanning electron microscopy (SEM) and transmission electron microscopy (TEM) with sample preparation via focused ion beam in situ-liftout-technique.

  8. Corrosion behavior of the tube - tubular plate joint zone in the presence of sediments

    International Nuclear Information System (INIS)

    Lucan, D.; Fulger, M.; Pirvan, I.; Cotolan, V.

    1997-01-01

    The corrosion is a very important problem which concerns the safe operation of steam generators. The predominant part of corrosion problems is related to the local concentration of aggressive species and/or to the impurities from the slow-flow regions, like those created by cracks in tube - tubular plate joint zones. The consequences of such local concentrations are very important and as such entail interest in the design and utilization of steam generators. This study presents the results of the corrosion tests performed under specific operation conditions of the secondary circuit in NPP (temperature, 260 o C; pressure, 5.1 MPa) on a crack simulating device made of carbon steel SA 508 cl.2 (forming the tubular plate) and Incoloy-800 (forming the tubes). The chemical medium of these tests was the following: solution of NaCl, 25g/l (pH=10.5); solution of NaCl, 50 g/l (pH=10.5); solution of NaCl, 75g/l (pH=10.5); solution of NaCl, 75g/l + solution of Na 2 SO 4 , 10 g/l (pH=10.5). The behavior of these two materials to corrosion was studied by metallographic investigations. The results are presented as microphotographs evidencing the occurrence of pitting corrosion first on material of the tubular plate, in the presence of medium particularly aggressive and on the material of the tubes. The aim of this study is to establish the corrosion mechanism as well as the formation of the oxide layer on the carbon steel in crack simulating devices. (authors)

  9. High Temperature Fuel Cladding Chemical Interactions Between TRIGA Fuels and 304 Stainless Steel

    International Nuclear Information System (INIS)

    Perez, Emmanuel; Keiser Jr, Dennis D.; Forsmann, Bryan; Janney, Dawn E.; Henley, Jody; Woolstenhulme, Eric C.

    2016-01-01

    High-temperature fuel-cladding chemical interactions (FCCI) between TRIGA (Training, Research, Isotopes, General Atomics) fuel elements and the 304 stainless steel (304SS) are of interest to develop an understanding of the fuel behavior during transient reactor scenarios. TRIGA fuels are composed of uranium (U) particles dispersed in a zirconium-hydride (Zr-H) matrix. In reactor, the fuel is encased in 304-stainless-steel (304SS) or Incoloy 800 clad tubes. At high temperatures, the fuel can readily interact with the cladding, resulting in FCCI. A number of FCCI can take place in this system. Interactions can be expected between the cladding and the Zr-H matrix, and/or between the cladding and the U-particles. Other interactions may be expected between the Zr-H matrix and the U-particles. Furthermore, the fuel contains erbium-oxide (Er-O) additions. Interactions can also be expected between the Er-O, the cladding, the Zr-H and the U-particles. The overall result is that very complex interactions may take place as a result of fuel and cladding exposures to high temperatures. This report discusses the characterization of the baseline fuel microstructure in the as-received state (prior to exposure to high temperature), characterization of the fuel after annealing at 950C for 24 hours and the results from diffusion couple experiments carries out at 1000C for 5 and 24 hours. Characterization was carried out via scanning electron microscopy (SEM) and transmission electron microscopy (TEM) with sample preparation via focused ion beam in situ-liftout-technique.

  10. The Seismic Analysis of 800kV Gas Insulated Switchgear (GIS) for the Dangjin Thermal Plant

    Energy Technology Data Exchange (ETDEWEB)

    Shin, I.H.; Song, W.P.; Kweon, K.Y. [Hyosung Corporation (Korea)

    1999-05-01

    800kV GIS (Gas Insulated Switchgear) which was first developed in korea at Dec. 1998 and is going to be installed in the dangjin thermal plant. We checked the stability of 800kV GIS under seismic load. pro-ENGINEER and PATRAN were used for modeling exactly 800kV GIS geometry. The 800kV GIS was modeled as shell elements for the enclosures and beam elements for the conductors and the support insulators. (author). 2 refs., 9 figs., 2 tabs.

  11. Heavy Hyperfragments produced by 800 MeV/c k in Nuclear Emulsions; Hiperfragmentos pesados producidos por K de 800 MeV c en emulsiones nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Marcial, P

    1967-07-01

    A statistical and phenomenological survey of nearly 1200 heavy hyperfragments produced by interaction of 800 MeV/c K with the heavy nuclei of llford K{sub 5} emulsion is presented. The emulsion was exposed A statistical and phenomenological survey of nearly 1200 heavy hyperfragments produced by interaction of 800 MeV/c K with the heavy nuclei of llford K5 emulsion is presented. The emulsion was exposed in Berkeley. The variation of long list of parameters dealing with both the production and desintegration of the hyperfragments, with the size of the primary interaction is given. (Author)

  12. 7 CFR 57.800 - Identification of restricted eggs.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Identification of restricted eggs. 57.800 Section 57... AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 AND THE EGG PRODUCTS INSPECTION ACT (CONTINUED) INSPECTION OF EGGS (EGG PRODUCTS INSPECTION ACT) Regulations Governing the Inspection of Eggs...

  13. Magnifying lens for 800 MeV proton radiography

    International Nuclear Information System (INIS)

    Merrill, F. E.; Campos, E.; Espinoza, C.; Hogan, G.; Hollander, B.; Lopez, J.; Mariam, F. G.; Morley, D.; Morris, C. L.; Murray, M.; Saunders, A.; Schwartz, C.; Thompson, T. N.

    2011-01-01

    This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.

  14. 9 CFR 590.800 - Identification of restricted eggs.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Identification of restricted eggs. 590... AGRICULTURE EGG PRODUCTS INSPECTION INSPECTION OF EGGS AND EGG PRODUCTS (EGG PRODUCTS INSPECTION ACT) Identification of Restricted Eggs Or Egg Products Not Intended for Human Consumption § 590.800 Identification of...

  15. A survey on the corrosion susceptibility of Alloy 800 CANDU steam generator tubing materials

    International Nuclear Information System (INIS)

    Lu, Y.C.; Dupuis, M.; Burns, D.

    2008-01-01

    To provide support for a proactive steam generator (SG) aging management strategy, a survey on the corrosion susceptibility of the archived Alloy 800 tubing from CANDU SGs under plausible crevice chemistry conditions was conducted to assess the potential material degradation issues in CANDU SGs. Archived Alloy 800 samples were collected from four CANDU utilities. High-temperature electrochemical analysis was carried out to assess the corrosion susceptibility of the archived SG tubing under simulated CANDU crevice chemistry conditions at both 150 o C and 300 o C. The potentiodynamic polarization results obtained from the archived CANDU SG tubes were compared to the data from ex-service tubes removed from Darlington Nuclear Generating Station (DNGS) SGs and a reference nuclear grade Alloy 800 tubing. It was found that the removed Darlington SG tubes, with signs of in-service degradation, were more susceptible to pitting corrosion than the reference nuclear grade Alloy 800 tubing. At 150 o C, under the same neutral crevice chemistry conditions, the potentiodynamic polarization curve of the ex-service Darlington SG tubing has an active peak, which is a sign of propensity to crevice/underdeposit corrosion. This active peak was not observed in any of the potentiodynamic polarization curves of all archived Alloy 800 CANDU SG tubing indicating that archived CANDU SG tubes are less susceptible to the underdeposit corrosion under SG startup conditions. The corrosion behaviour of the archived Alloy 800 tubes from CANDU SG was similar to that of the reference nuclear grade Alloy 800 tubing. The results of this survey suggest that the Alloy 800 tubing materials used in the existing CANDU utilities (other than ex-service DNGS tubing) will continue to have reliable performance under specified CANDU operating conditions. Ex-service SG tubing from DNGS, although showing lower than average corrosion resistance, still has a wide acceptable operating margin and the in

  16. RBS/channeling analysis of hydrogen-implanted single crystals of FZ silicon and 6H silicon

    International Nuclear Information System (INIS)

    Irwin, R.B.

    1984-01-01

    Single crystals of FZ silicon and 6H silicon carbide were implanted with hydrogen ions (50 and 80 keV, respectively) to fluences from 2 x 10 16 H + /cm 2 to 2 x 10 18 H+/cm 2 . The implantations were carried out at three temperatures: approx.95K, 300 K, and approx.800 K. Swelling of the samples was measured by surface profilometry. RBS/channeling was used to obtain the damage profiles and to determine the amount of hydrogen retained in the lattice. The damage profiles are centered around X/sub m/ for the implants into silicon and around R/sub p/ for silicon carbide. For silicon carbide implanted at 95 K and 300 K and for silicon implanted at 95 K, the peak damage region is amorphous for fluences above 8 x 10 16 H + /cm 2 , 4 x 10 17 H + /cm 2 , and 2 x 10 17 H + /cm 2 , respectively. Silicon implanted at 300 and 800 K and silicon carbide implanted at 800 K remain crystalline up to fluences of 1 x 10 18 H + /cm 2 . The channeling damage results agree with previously reported TEM and electron diffraction data. The predictions of a simple disorder-accumulation model with a linear annealing term explains qualitatively the observed damage profiles in silicon carbide. Quantitatively, however, the model predicts faster development of the damage profiles than is observed at low fluences in both silicon and silicon carbide. For samples implanted at 300 and 800 K, the model also predicts substantially less peak disorder than is observed. The effect of the surface, the retained hydrogen, the shape of S/sub D/(X), and the need for a nonlinear annealing term may be responsible for the discrepancy

  17. 7 CFR 97.800 - Publication of public variety descriptions.

    Science.gov (United States)

    2010-01-01

    ... Section 97.800 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY... Office will be accepted for publication in the Official Journal. Such publication shall not constitute...

  18. The metallurgy of alloy 800

    International Nuclear Information System (INIS)

    Stone, P.G.; Orr, J.; Guest, J.C.

    1975-01-01

    Following a review of published information on the metallurgy of the iron/chromium/nickel system, attention is directed to the metallurgical significance of relatively minor compositional variations introduced in Alloy 800 to meet the stress corrosion requirements of the nuclear power industry. These include the effect of carbon, nitrogen, titanium, and aluminium restrictions in the context of Light Water Reactor, High Temperature Reactor, and Fast Reactor applications. Solubility effects are also considered in relation to heat treatment procedures, metallurgical phenomena, and associated properties. The aging behaviour is also discussed and related to fabrication and service performance; particularly stress rupture behaviour. The effect of strain at ambient and elevated temperatures on these aspects is indicated. (author)

  19. Preliminary design of the cooling system for a gas-cooled, high-fluence fast pulsed reactor (HFFPR)

    International Nuclear Information System (INIS)

    Monteith, H.C.

    1978-10-01

    The High-Fluence Fast Pulsed Reactor (HFFPR) is a research reactor concept currently being evaluated as a source for weapon effects experimentation and advanced reactor safety experiments. One of the designs under consideration is a gas-cooled design for testing large-scale weapon hardware or large bundles of full-length, fast reactor fuel pins. This report describes a conceptual cooling system design for such a reactor. The primary coolant would be helium and the secondary coolant would be water. The size of the helium-to-water heat exchanger and the water-to-water heat exchanger will be on the order of 0.9 metre (3 feet) in diameter and 3 metres (10 feet) in length. Analysis indicates that the entire cooling system will easily fit into the existing Sandia Engineering Reactor Facility (SERF) building. The alloy Incoloy 800H appears to be the best candidate for the tube material in the helium-to-water heat exchanger. Type 316 stainless steel has been recommended for the shell of this heat exchanger. Estimates place the cost of the helium-to-water heat exchanger at approximately $100,000, the water-to-water heat exchanger at approximately $25,000, and the helium pump at approximately $450,000. The overall cost of the cooling system will approach $2 million

  20. Rhodamine 800 as reference substance for fluorescence quantum yield measurements in deep red emission range

    Energy Technology Data Exchange (ETDEWEB)

    Alessi, A., E-mail: andrea.alessi@eni.com [Centro Ricerche per le Energie non Convenzionali, Istituto eni Donegani, e.n.i. S.p.A., Via G. Fauser 4, 28100 Novara (Italy); Salvalaggio, M. [Centro Ricerche per le Energie non Convenzionali, Istituto eni Donegani, e.n.i. S.p.A., Via G. Fauser 4, 28100 Novara (Italy); Ruzzon, G. [HORIBA Jobin Yvon Srl, Via Cesare Pavese 35/AB, 20090 Opera Milano (Italy)

    2013-02-15

    The determination of fluorescence quantum yields ({Phi}{sub f}) of deep red dyes emitting at 635-900 nm is difficult due to lack of suitable standards. In this work, we propose a commercial dye, rhodamine 800 (Rho800), as reference standard which belongs to the family of xanthenes. The quantum yield of rhodamine 800 in absolute ethanol has been studied using a relative method with cresyl violet (CV) and rhodamine 101 (Rho101) as references, and an absolute fluorometric method by integrating sphere measurements. - Highlights: Black-Right-Pointing-Pointer A red emitting dye Rhodamine 800 was electronic spectroscopy characterized. Black-Right-Pointing-Pointer Its fluorescence quantum yield was studied using a relative and an absolute method. Black-Right-Pointing-Pointer The values found are greater than the values currently known in the literature.

  1. Penentuan konsentrasi stainless steel 316L dan kobalt kromium remanium GM-800 pada uji GPMT

    Directory of Open Access Journals (Sweden)

    Ikmal Hafizi

    2016-12-01

    Full Text Available Concentration determination of stainless steel 316L and cobalt chromium remanium GM - 800 on GPMT test. Dentistry had used metals such as cobalt chromium and stainless steel in maxillofacial surgery, cardiovascular, and as a dental material. 316L stainless steel is austenistic stainless steel which has low carbon composition to improve the corrosion resistance as well as the content of molybdenum in the material. Cobalt chromium (CoCr is a cobaltbased alloy with a mixture of chromium. Density of a metal cobalt chromium alloy is about 8-9 g/cm3 that caused metal interference relatively mild. Remanium GM-800 is one type of a cobalt chromium alloy with the advantages of having high resistance to fracture and high modulus of elasticity. This study aims to determine the exact concentration used in 316L stainless steel and cobalt chromium GM-800 as the GPMT test material. Subjects were cobalt chromium Remanium GM-800 and 316L stainless steel concentration of 5%, 10%, 20%, 40% and 80%. Patch containing stainless steel or cobalt chromium paste was af xed for 24 hours each on three experimental animals, then the erythema and edema were observed using the Magnusson and Kligman scale. In the study, concentration of 5% is the concentration recommended for stainless steel 316L and cobalt chromium GM-800 as material in challenge phase GPMT test, while the concentration of 40% is the concentration recommended for stainless steel 316L and cobalt chromium GM-800 in the induction phase. ABSTRAK Dunia kedokteran gigi banyak menggunakan logam pada pembedahan maxillofacial, cardiovascular, dan sebagai material dental. Logam yang banyak digunakan antara lain adalah kobalt kromium dan stainless steel. Stainless steel 316L merupakan austenistic stainless steel yang memiliki komposisi karbon rendah sehingga dapat meningkatkan ketahanan terhadap korosi sama halnya dengan kandungan molybdenum pada material tersebut. Kobalt kromium (CoCr adalah cobalt-based alloy dengan

  2. Progressive degradation of alloy 690 and the development of a significant improvement in alloy 800CR

    International Nuclear Information System (INIS)

    Staehle, Roger W.; Arioka, Koji; Tapping, Robert

    2015-01-01

    The present most widely used alloys for tubing in steam generators and structural materials in water cooled reactors are Alloy 690 and Alloy 800. However, both alloys, while improved over Alloy 600 may not meet the needs of longer range applications in the range of 80-100 years. Alloy 690 sustains damage resulting from the formation of cavities at grain boundaries which eventually cover about 50% of the area of the grain boundaries with the remainder covering being covered with carbides. The cavities seem to nucleate on the carbides leaving the grain boundaries a structure of cavities and carbides. Such a structure will lead the Alloy 690 to fail completely. Normal Alloy 800 does not produce such cavities and probably retains a large amount of its corrosion resistance but does sustain progressive SCC at low rate. A new alloy, 800CR, has been developed in a collaboration among Arioka, Tapping, and Staehle. This alloy is based on a Cr composition of 23.5-27% with the remainder retaining the previous Alloy 800 composition. 800CR sustains a crack velocity about 100 times less than Alloy 690 and a negligible rate of initiation. The 800CR, alloy is now seeking a patent. (authors)

  3. Theoretical-experimental assessment of the variables affecting fretting of Atucha I nuclear power plant utility steam generators tubes

    International Nuclear Information System (INIS)

    Kulichevsky, Raul M.

    1995-01-01

    Fretting wear of Steam Generator tubes caused by flow induced vibrations generates uncertainty on their integrity. The knowledge of the controlling variables of the wear process may give a criterion to evaluate the tubes residual life. Information on vibratory response and dynamic interaction between tubes and their supports are prerequisites for understanding the relationship between fretting wear and tube vibration. Experimental results of the vibratory response of an Atucha-I nuclear power plant type U-tube, the influence of tube/support clearance on this response and a study of tube/support dynamic interaction, which allow the verification of a finite element model of this type of tubes, are presented in this work. Also wear results for the Incoloy 800/DIN 1.4550 austenitic stainless steel pair of materials and a first evaluation of the wear constant of this pair are presented. (author)

  4. Steam generator materials and secondary side water chemistry in nuclear power stations

    International Nuclear Information System (INIS)

    Rudelli, M.D.

    1979-04-01

    The main purpose of this work is to summarize the European and North American experiences regarding the materials used for the construction of the steam generators and their relative corrosion resistance considering the water chemestry control method. Reasons underlying decision for the adoption of Incoloy 800 as the material for the secondary steam generator system for Atucha I Nuclear Power Plant (Atucha Reactor) and Embalse de Rio III Nuclear Power Plant (Cordoba Reactor) are pointed out. Backup information taken into consideration for the decision of utilizing the All Volatil Treatment for the water chemistry control of the Cordoba Reactor is detailed. Also all the reasonswhich justify to continue with the congruent fosfatic method for the Atucha Reactor are analyzed. Some investigation objectives which would eventually permit the revision of the decisions taken on these subjects are proposed. (E.A.C.) [es

  5. Analysis of structural materials for fast-breeder reactors by X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Roca, M.; Diaz-Guerra, J.P.

    1978-01-01

    A procedure for the X-ray spectrometric determination of Co, Cr, Cu, Mn, Mo, Nb, Ni, P, S, Si and Ti in stainless steels and some nickel-base alloys, such as incoloy-800, is described. The use of different sets of standards has allowed the calculation of the inter-element influence coefficients for the correction of matrix effects, making the method suited for wide concentration range determinations. The efficiency of X-ray tubes with Cr and W targets has been studied, the former allowing the determination of all the above-named elements. The average relative error is 3.7%, except for P and S, where the determinations are semiquantitative. The use of a programmable spectrometer interfaced with a 16 K computer facilitates considerably the treatment of data with a proper mathematic model and furthermore provides an automatic performance of the analyses. (author)

  6. International standard on auditing 800 the auditor`s report on special purpose audit engagements

    OpenAIRE

    Jovanova, Blagica

    2011-01-01

    The purpose of this report is to show the main characteristics of the international standard on auditing 800. ISA 800 explains requirements by making a report on financial statements prepared in accordance with another comprehensive basis of accounting, on a component of financial statements, on compliance with contractual agreements or reports on summarized financial statements.

  7. Low Cost Silicon Solar Array Project. Feasibility of Low-cost, High-volume Production of Silane and Pyrolysis of Silane to Semiconductor-grade Silicon

    Science.gov (United States)

    Breneman, W. C.; Farrier, E. G.; Morihara, H.

    1978-01-01

    The presence of copper promotes a more rapid approach to the steady stete operating condition and results in a more consistent reactor effluent composition. The average kinetic and equilibrium yield are unchanged. Incoloy has been identified as the preferred choice of material of construction for the hydrogenation reactor although certain metallurgical changes were noted in samples exposed to the H2/HCl atmosphere at 500 C which indicate the need for more testing.

  8. Construction and Test Results of Coils 2 and 3 of a 3-Nested-Coil 800-MHz REBCO Insert for the MIT 1.3-GHz LTS/HTS NMR Magnet.

    Science.gov (United States)

    Park, Dongkeun; Bascuñán, Juan; Michael, Philip C; Lee, Jiho; Hahn, Seungyong; Iwasa, Yukikazu

    2018-04-01

    We present construction and test results of Coils 2 and 3 of a 3-coil 800-MHz REBCO insert (H800) for the MIT 1.3 GHz LTS/HTS NMR magnet currently under construction. Each of three H800 coils (Coils 1-3) is a stack of no-insulation REBCO double pancakes (DPs). The innermost 8.67-T Coil 1 (26 DPs) was completed in 2016; the middle 5.64-T Coil 2 (32 DPs) has been wound, assembled, and tested; and for the outermost 4.44-T Coil 3, its 38 DPs have been wound and preliminary tests were performed to characterize each DP at 77 K. Included for Coil 2 are: 1) 77-K data of critical current, index, and turn-to-turn characteristic resistivity of each DP; 2) stacking order of the 32 DPs optimized to maximize the Coil 2 current margin and minimize its Joule dissipation in the pancake-to-pancake joints; 3) procedure to experimentally determine and apply a room-temperature preload to the DP stack; 4) 77-K and 4.2-K test results after each of 64 pancakes was over-banded with 75-μm-thick stainless steel tape for a radial thickness of 5 mm. Presented for each DP in Coil 3 are 77-K dada of critical current, index, and turn-to-turn characteristic resistivity.

  9. Friction and wear behavior of laser cladding Ni/hBN self-lubricating composite coating

    International Nuclear Information System (INIS)

    Zhang Shitang; Zhou Jiansong; Guo Baogang; Zhou Huidi; Pu Yuping; Chen Jianmin

    2008-01-01

    Ni/hBN coating was successfully prepared on 1Cr18Ni9Ti stainless steel substrate by means of laser cladding. The microhardness profile of the composite coating along the depth direction was measured, while its cross-sectional microstructures and phase compositions were analyzed by means of scanning electron microscopy and X-ray diffraction. Moreover, the friction and wear behavior of the composite coatings sliding against Si 3 N 4 from ambient to 800 deg. C was evaluated using a ball-on-disc friction and wear tester, and the worn surface morphologies of the composite coatings and counterpart ceramic balls were observed using a scanning electron microscope. At the same time, the worn surfaces of the ceramic balls were also analyzed using a 3D non-contact surface mapping profiler as well. It was found that the laser cladding Ni/hBN coating on the stainless steel substrate had high microhardness and good friction-reducing and antiwear abilities at elevated temperatures up to 800 deg. C. The composite coating registered slightly increased friction coefficient and wear rate as the temperature rose from ambient to 100 deg. C; then the friction coefficient and wear rate decreased with increasing temperature up to 800 deg. C (with the slight increase in the wear rate at 700 deg. C and 800 deg. C to be an exception). The laser cladding Ni/hBN coating was dominated by mixed adhesion and abrasive wear as it slid against the ceramic ball below 300 deg. C. With further increase in the test temperature up to 400 deg. C and above, it was characterized by mild adhesion wear and plastic deformation. Since the laser cladding Ni/hBN coating registered an increased wear rate at temperatures of 600 deg. C and above, it was not suggested to be used for wear prevention and protection of the stainless steel at elevated temperature above 800 deg. C

  10. Friction and wear behavior of laser cladding Ni/hBN self-lubricating composite coating

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Shitang [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate School, Chinese Academy of Sciences, Beijing 100039 (China); Zhou Jiansong [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Guo Baogang [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate School, Chinese Academy of Sciences, Beijing 100039 (China); Zhou Huidi [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Pu Yuping [Central Iron and Steel Research Institute, Beijing 100081 (China); Chen Jianmin [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)], E-mail: chenjm@lzb.ac.cn

    2008-09-15

    Ni/hBN coating was successfully prepared on 1Cr18Ni9Ti stainless steel substrate by means of laser cladding. The microhardness profile of the composite coating along the depth direction was measured, while its cross-sectional microstructures and phase compositions were analyzed by means of scanning electron microscopy and X-ray diffraction. Moreover, the friction and wear behavior of the composite coatings sliding against Si{sub 3}N{sub 4} from ambient to 800 deg. C was evaluated using a ball-on-disc friction and wear tester, and the worn surface morphologies of the composite coatings and counterpart ceramic balls were observed using a scanning electron microscope. At the same time, the worn surfaces of the ceramic balls were also analyzed using a 3D non-contact surface mapping profiler as well. It was found that the laser cladding Ni/hBN coating on the stainless steel substrate had high microhardness and good friction-reducing and antiwear abilities at elevated temperatures up to 800 deg. C. The composite coating registered slightly increased friction coefficient and wear rate as the temperature rose from ambient to 100 deg. C; then the friction coefficient and wear rate decreased with increasing temperature up to 800 deg. C (with the slight increase in the wear rate at 700 deg. C and 800 deg. C to be an exception). The laser cladding Ni/hBN coating was dominated by mixed adhesion and abrasive wear as it slid against the ceramic ball below 300 deg. C. With further increase in the test temperature up to 400 deg. C and above, it was characterized by mild adhesion wear and plastic deformation. Since the laser cladding Ni/hBN coating registered an increased wear rate at temperatures of 600 deg. C and above, it was not suggested to be used for wear prevention and protection of the stainless steel at elevated temperature above 800 deg. C.

  11. System 800xA - a control system for the next generation of power plants; System 800xA - Das Leitsystem der naechsten Kraftwerksgeneration

    Energy Technology Data Exchange (ETDEWEB)

    Bruns, H. [ABB AG, Mannheim (Germany); Lauxtermann, S. [ABB AG, Minden (Germany)

    2006-07-01

    The system 800 x A developed by ABB is a power plant control system that is capable of combining the latest technologies in this field with best-practice solutions and integrating the I and C equipment already installed in a plant. System 800 x A offers plant owners a future-oriented integration platform for process control and sub-station control systems on the basis of the new IEC 61850 standard. Through optimised integration and networking of information in combination with direct and context-sensitive information access, decision-taking processes and the analysis of disturbances are speeded up considerably. Consistent data structures, ranging from field data to plant management data, and a simplified system configuration can reliably lower the system operating costs and increase operational reliability for a long time. This consistent technology can integrate turbine automation, unit automation, and all sorts of control functions and thus create single-source automation solutions that are highly harmonised and easy to handle. (orig.)

  12. 30 CFR 942.800 - Bond and insurance requirements for surface coal mining and reclamation operations.

    Science.gov (United States)

    2010-07-01

    ... required for postmining water treatment must remain bonded. However, the trust fund or annuity may serve as... coal mining and reclamation operations. 942.800 Section 942.800 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR PROGRAMS FOR THE CONDUCT OF SURFACE MINING...

  13. D/H fractionation in the H2-H2O system at supercritical water conditions: Compositional and hydrogen bonding effects

    Science.gov (United States)

    Foustoukos, Dionysis I.; Mysen, Bjorn O.

    2012-06-01

    A series of experiments has been conducted in the H2-D2-D2O-H2O-Ti-TiO2 system at temperatures ranging from 300 to 800 °C and pressures between ∼0.3 and 1.3 GPa in a hydrothermal diamond anvil cell, utilizing Raman spectroscopy as a quantitative tool to explore the relative distribution of hydrogen and deuterium isotopologues of the H2 and H2O in supercritical fluids. In detail, H2O-D2O solutions (1:1) were reacted with Ti metal (3-9 h) in the diamond cell, leading to formation of H2, D2, HD, and HDO species through Ti oxidation and H-D isotope exchange reactions. Experimental results obtained in situ and at ambient conditions on quenched samples indicate significant differences from the theoretical estimates of the equilibrium thermodynamic properties of the H-D exchange reactions. In fact, the estimated enthalpy for the H2(aq)-D2(aq) disproportionation reaction (ΔHrxn) is about -3.4 kcal/mol, which differs greatly from the +0.16 kcal/mol predicted for the exchange reaction in the gas phase by statistical mechanics models. The exothermic behavior of the exchange reaction implies enhanced stability of H2 and D2 relative to HD. Accordingly, the significant energy difference of the internal H2(aq)-D2(aq)-HD(aq) equilibrium translates to strong differences of the fractionation effects between the H2O-H2 and D2O-D2 isotope exchange relationships. The D/H fractionation factors between H2O-H2(aq) and D2O-D2(aq) differ by 365‰ in the 600-800 °C temperature range, and are indicative of the greater effect of D2O contribution to the δD isotopic composition of supercritical fluids. The negative ΔHrxn values for the H2(aq)-D2(aq)-HD(aq) equilibrium and the apparent decrease of the equilibrium constant with increasing temperature might be because of differences of the Henry’s law constant between the H- and D-bearing species dissolved in supercritical aqueous solutions. Such effects may be attributed to the stronger hydrogen bonding in the O-H⋯O relative to the

  14. Radiology of the AS 800 artificial urinary sphincter

    International Nuclear Information System (INIS)

    Hamilton, S.; Shetty, M.K.; Flood, H.D.; Grainger, R.

    1991-01-01

    Thirteen adult male patients who had an AS 800 artificial urinary sphincter inserted are reviewed. Five have had malfunction, and in four the causes were diagnosed radiologically. These included: fistula formation, leakage of hydraulic fluid, air in the system, and inadequate deflation of the cuff. Since the sphincter is filled with contrast medium, it is ideally suited to radiological assessment. (author). 5 refs.; 6 figs

  15. 1300°F 800 MWe USC CFB Boiler Design Study

    Science.gov (United States)

    Robertson, Archie; Goidich, Steve; Fan, Zhen

    Concern about air emissions and the effect on global warming is one of the key factors for developing and implementing new advanced energy production solutions today. One state-of-the-art solution is circulating fluidized bed (CFB) combustion technology combined with a high efficiency once-through steam cycle. Due to this extremely high efficiency, the proven CFB technology offers a good solution for CO2 reduction. Its excellent fuel flexibility further reduces CO2 emissions by co-firing coal with biomass. Development work is under way to offer CFB technology up to 800MWe capacities with ultra-supercritical (USC) steam parameters. In 2009 a 460MWe once-through supercritical (OTSC) CFB boiler designed and constructed by Foster Wheeler will start up. However, scaling up the technology further to 600-800MWe with net efficiency of 45-50% is needed to meet the future requirements of utility operators. To support the move to these larger sizes, an 800MWe CFB boiler conceptual design study was conducted and is reported on herein. The use of USC conditions (˜11 00°F steam) was studied and then the changes, that would enable the unit to generate 1300°F steam, were identified. The study has shown that by using INTREX™ heat exchangers in a unique internal-external solids circulation arrangement, Foster Wheeler's CFB boiler configuration can easily accommodate 1300°F steam and will not require a major increase in heat transfer surface areas.

  16. Studies on the growth of oxide films on alloy 800 and alloy 600 in lithiated water at high temperature

    International Nuclear Information System (INIS)

    Olmedo, A.M.; Bordon, R.

    2007-01-01

    In this work, the oxide films grown on Alloy 800 and Alloy 600 in lithiated (pH 25 C d egrees = 10.2-10.4) water at high temperature, with and without hydrogen overpressure (HO) and an initial oxygen dissolved in the water have been studied. The oxide films were grown at different temperatures (220-350 C degrees) and exposure times with HO, and at 315 C degrees without HO in static autoclaves. Some results are also reported for oxide layers grown on Alloy 800 coupons exposed in a high temperature loop during extended exposure times. The average oxide thickness was determined using descaling procedures. The morphology and composition of the oxide films were analyzed with scanning electron microscopy (SEM), EDS and X-ray diffraction (XRD). For both Alloys, at 350 C degrees with HO, the oxide layers were clearly composed of a double layer: an inner one of very small crystallites and an outer layer formed by bigger crystals scattered over the inner one. The analysis by X-ray diffraction indicated the presence of spinel structures like magnetite (Fe 3 O 4 ) and ferrites and/or nickel chromites. In this case the average oxide thickness was around 0.12 to 0.15 μm for both Alloys. Similar values were found at lower temperatures. The morphology of the oxide layer was similar at lower temperatures for Alloy 800, but a different morphology consisting of platelets or needles was found for Alloy 600. The oxide morphology found at 315 C degrees, without HO and with initial dissolved oxygen in the water, was also very different between both Alloys. The oxide film grown on Alloy 600 with an initial dissolved oxygen in the water, showed clusters of platelets forming structures like flowers that were dispersed on an rather homogeneous layer consisting of smaller platelets or needles. The average oxide film grown in this case was around 0.25 μm for Alloy 600 and 0.18 μm for Alloy 800. (author) [es

  17. Characterization of Laves phase in Crofer 22 H stainless steel.

    Science.gov (United States)

    Hsiao, Zheng-Wen; Kuhn, Bernd; Chen, Delphic; Singheiser, Lorenz; Kuo, Jui-Chao; Lin, Dong-Yih

    2015-07-01

    This study investigated the effect of annealing temperature on the precipitation behavior of Crofer(®) 22 H at 600°C, 700°C, and 800°C. The grain size distribution, precipitate phase identification, and microstructure were analyzed using electron backscatter diffraction (EBSD) and energy dispersive X-ray spectroscopy (EDS). The morphology of Laves phase (Fe,Cr,Si)(2)(Nb,W) precipitates having the Cr(2)Nb structure changed from strip-like to needle-shaped as the annealing temperature was increased. The precipitates of the Laves phase also shifted from the grain boundaries to the grain interiors when the temperature was increased. However, the average grain size (150 μm) of the ferritic matrix did not significantly change at 600°C, 700°C, and 800°C for 10 h. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. 120 MW, 800 MHz Magnicon for a Future Muon Collider

    International Nuclear Information System (INIS)

    Jay L. Hirshfield

    2005-01-01

    Development of a pulsed magnicon at 800 MHz was carried out for the muon collider application, based on experience with similar amplifiers in the frequency range between 915 MHz and 34.3 GHz. Numerical simulations using proven computer codes were employed for the conceptual design, while established design technologies were incorporated into the engineering design. A cohesive design for the 800 MHz magnicon amplifier was carried out, including design of a 200 MW diode electron gun, design of the magnet system, optimization of beam dynamics including space charge effects in the transient and steady-state regimes, design of the drive, gain, and output cavities including an rf choke in the beam exit aperture, analysis of parasitic oscillations and design means to eliminate them, and design of the beam collector capable of 20 kW average power operation

  19. Heavy Hyperfragments produced by 800 MeV/c k in Nuclear Emulsions

    International Nuclear Information System (INIS)

    Marcial, P.

    1967-01-01

    A statistical and phenomenological survey of nearly 1200 heavy hyperfragments produced by interaction of 800 MeV/c K with the heavy nuclei of llford K 5 emulsion is presented. The emulsion was exposed A statistical and phenomenological survey of nearly 1200 heavy hyperfragments produced by interaction of 800 MeV/c K tilde with the heavy nuclei of llford K5 emulsion is presented. The emulsion was exposed in Berkeley. The variation of long list of parameters dealing with both the production and desintegration of the hyperfragments, with the size of the primary interaction is given. (Author)

  20. Relationships between Sprint, Jumping and Strength Abilities, and 800 M Performance in Male Athletes of National and International Levels.

    Science.gov (United States)

    Bachero-Mena, Beatriz; Pareja-Blanco, Fernando; Rodríguez-Rosell, David; Yáñez-García, Juan Manuel; Mora-Custodio, Ricardo; González-Badillo, Juan José

    2017-09-01

    This study analysed the relationships between sprinting, jumping and strength abilities, with regard to 800 m running performance. Fourteen athletes of national and international levels in 800 m (personal best: 1:43-1:58 min:ss) completed sprint tests (20 m and 200 m), a countermovement jump, jump squat and full squat test as well as an 800 m race. Significant relationships (p relationship between the first to the last 50 m interval times and the 800 m time tended to increase (1st 50 m: r = 0.71; 2nd 50 m: r = 0.72; 3rd 50 m: r = 0.81; 4th 50 m: r = 0.85). Performance in 800 m also correlated significantly (p < 0.01-0.05) with strength variables: the countermovement jump (r = -0.69), jump squat (r = -0.65), and full squat test (r = -0.58). Performance of 800 m in high-level athletes was related to sprint, strength and jumping abilities, with 200 m and the latest 50 m of the 200 m being the variables that most explained the variance of the 800 m performance.

  1. Updating the HST/ACS G800L Grism Calibration

    Science.gov (United States)

    Hathi, Nimish P.; Pirzkal, Norbert; Grogin, Norman A.; Chiaberge, Marco; ACS Team

    2018-06-01

    We present results from our ongoing work on obtaining newly derived trace and wavelength calibrations of the HST/ACS G800L grism and comparing them to previous set of calibrations. Past calibration efforts were based on 2003 observations. New observations of an emission line Wolf-Rayet star (WR96) were recently taken in HST Cycle 25 (PID: 15401). These observations are used to analyze and measure various grism properties, including wavelength calibration, spectral trace/tilt, length/size of grism orders, and spacing between various grism orders. To account for the field dependence, we observe WR96 at 3 different observing positions over the HST/ACS field of view. The three locations are the center of chip 1, the center of chip 2, and the center of the WFC1A-2K subarray (center of WFC Amp A on chip 1). This new data will help us to evaluate any differences in the G800L grism properties compared to previous calibration data, and to apply improved data analysis techniques to update these old measurements.

  2. A review of the structural characteristics of alloy 800

    International Nuclear Information System (INIS)

    Orr, J.

    1978-01-01

    The published literature is reviewed and supplemented by current information from the author's laboratory, to show the influence of various compositional, heat treatment and thermomechanical factors on the structural characteristics of Alloy 800. The features discussed include carbon, aluminium, titanium and boron, solution treatment, ageing treatments with and without applied strain, and cold working. Examples of the aspects reviewed include the effect of heat treatment and service or testing temperature on the austenite grain size, and the relative importance of M 23 C 6 and TiC, the influence of carbon level on gamma prime, the effect of residual or steady stress combined with time at temperature on changes in carbide or gamma prime morphology, and on the appearance of sigma or other intermetallic phases. The questions posed by these features are discussed generally, in terms of their effect on the mechanical properties at ambient and elevated temperatures and on the time-dependent properties. The review also suggests areas where further research work is required on Alloy 800. (Auth.)

  3. 75 FR 15321 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2010-03-29

    ... Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation Administration... Based on the service information, we estimate that this AD will affect about 138 RB211 Trent 800 series... will cost about $2,000 per engine. Based on these figures, we estimate the cost of the AD on U.S...

  4. Perfect 800 Advanced Strategies for Top Students

    CERN Document Server

    Celenti, Dan

    2010-01-01

    Getting into the nation's most competitive universities requires more than a good SAT score, it requires a perfect score. Perfect 800: SAT Math gives advanced students the tools needed to master the SAT math test. Covering areas including arithmetic concepts; algebra; geometry; and additional topics such as probability and weighted average, the book offers exposure to a wide range of degrees of difficulty in a holistic approach that allows students to experience the "real thing," including the impact of time constraints on their performance. By emphasizing critical thinking and analytic skills

  5. The H2 control problem: a general transfer-function solution

    Czech Academy of Sciences Publication Activity Database

    Kučera, Vladimír

    2007-01-01

    Roč. 80, č. 5 (2007), s. 800-815 ISSN 0020-7179 Institutional research plan: CEZ:AV0Z10750506 Keywords : linear system * polynomial design methods * H_2 control problem Subject RIV: BC - Control Systems Theory Impact factor: 0.861, year: 2007

  6. X-ray measurement of residual stress in metals at Chalk River Nuclear Laboratories

    International Nuclear Information System (INIS)

    Winegar, J.E.

    1980-06-01

    X-ray diffraction is used at CRNL to measure residual stress in metals. This report summarizes the basic principles of stress measurement, and reviews factors affecting accuracy of measurement. The technique and equipment described were developed at CRNL to give reliable measurements. Accuracy of measurement is achieved by using fixed-count step-scanning and by computer analysis of intensity data using a cubic spline curve smoothing routine. Specific reference is made to the measurement of residual stress in Inconel-600 and Incoloy-800 boiler tubing. Because it measures stress in thin surface layers, the X-ray method can also be used to measure the depth profile of stresses. As there are no standardized procedures for measuring residual stress, this report will be useful both to those unfamiliar with the measurement of residual stress and to those already making such measurements in other laboratories. (auth)

  7. Arc-discharge system for nondestructive detection of flaws in thin ceramic coatings

    International Nuclear Information System (INIS)

    Scott, G.W.; Davis, E.V.

    1978-04-01

    The feasibility of nondestructively detecting small cracks or holes in plasma-sprayed ceramic coatings with an electric arc-discharge system was studied. We inspected ZrO 2 coatings 0.46 mm (0.018 in.) thick on Incoloy alloy 800 substrates. Cracks were artificially induced in controlled areas of the specimens by straining the substrates in tension. We designed and built a system to scan the specimen's surface at approximately 50 μm (0.002 in.) clearance with a sharp-pointed metal-tipped probe at high dc potential. The system measures the arc currents occurring at flaws, or plots a map of the scanned area showing points where the arc current exceeds a preset threshold. A theoretical model of the probe-specimen circuit shows constant dc potential to be the best choice for arc-discharge inspection of insulating coatings. Experimental observations and analysis of the data disclosed some potential for flaw description

  8. Reversible p-type conductivity in H passivated nitrogen and phosphorous codoped ZnO thin films using rapid thermal annealing

    Energy Technology Data Exchange (ETDEWEB)

    Mannam, Ramanjaneyulu, E-mail: ramu.nov9@gmail.com [Department of Physics, Nano Functional Materials Technology Centre and Materials Science Research Centre, Indian Institute of Technology Madras, Chennai 600036 (India); Kumar, E. Senthil [SRM Research Institute, Department of Physics and Nanotechnology, SRM University, Kattankulathur 603203, Tamil Nadu (India); DasGupta, Nandita [Microelectronics and MEMS Laboratory, Electrical Engineering Department, Indian Institute of Technology Madras, Chennai 600036 (India); Ramachandra Rao, M.S., E-mail: msrrao@iitm.ac.in [Department of Physics, Nano Functional Materials Technology Centre and Materials Science Research Centre, Indian Institute of Technology Madras, Chennai 600036 (India)

    2017-04-01

    Highlights: • Electrical transport measurements revel that the (P, N) codoped ZnO thin films exhibited change in conductivity from p-type to n-type over a span of 120 days. • Hydrogen and carbon are found to be the main unintentional impurities in n-type (P, N) codoped ZnO thin films. • Rapid thermal annealing has been used to remove both H and C from the films. • Carbon can be removed at an annealing temperature of 600 °C, whereas, the dissociation of N−H complex takes place only at 800 °C. • The n-type (P, N) codoped ZnO thin film exhibited change in conductivity to p-type at an annealing temperature of 800 °C. - Abstract: We demonstrate reversible p-type nature of pulsed laser deposited (P, N) codoped ZnO thin films using rapid thermal annealing process. As grown thin films exhibited change in conductivity from p to n-type over a span of 120 days. Non-annealed n-type thin films contain unintentional donor impurities such as hydrogen and carbon. X-ray photoelectron spectroscopy and Raman measurements conclusively show that hydrogen passivates nitrogen acceptors by forming N−H complex. Carbon can be annealed out at 600 °C, whereas, the dissociation of N−H complex takes place at 800 °C. The films revert its p-type nature at an annealing temperature of 800 °C.

  9. Cross sections from 800 MeV proton irradiation of terbium

    Energy Technology Data Exchange (ETDEWEB)

    Engle, J.W., E-mail: jwengle@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Mashnik, S.G.; Bach, H.; Couture, A.; Jackman, K.; Gritzo, R.; Ballard, B.D.; Fassbender, M.; Smith, D.M.; Bitteker, L.J.; Ullmann, J.L.; Gulley, M.S.; Pillai, C.; John, K.D.; Birnbaum, E.R. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Nortier, F.M., E-mail: meiring@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2012-11-02

    Terbium foils were irradiated with 800 MeV protons to ascertain the potential for production of lanthanide isotopes of interest in medical, astrophysical, and basic science research and to contribute to nuclear data repositories. Isotopes produced in the foil were quantified by gamma spectroscopy. Cross sections for 35 isotopes produced in the irradiation are reported and compared with predictions by the MCNP6 transport code using the CEM03.03, Bertini and INCL + ABLA event generators. Our results indicate the need to accurately consider fission and fragmentation of relatively light target nuclei like terbium in the modeling of nuclear reactions at 800 MeV. The predictive power of the code was found to be different for each event generator tested but was satisfactory for most of the product yields in the mass region where spallation reactions dominate. However, none of the event generators' results are in complete agreement with measured data.

  10. Tactical Behaviors in Men's 800-m Olympic and World-Championship Medalists: A Changing of the Guard.

    Science.gov (United States)

    Sandford, Gareth N; Pearson, Simon; Allen, Sian V; Malcata, Rita M; Kilding, Andrew E; Ross, Angus; Laursen, Paul B

    2018-02-01

    To assess the longitudinal evolution of tactical behaviors used to medal in men's 800-m Olympic Games (OG) or world-championship (WC) events in the recent competition era (2000-2016). Thirteen OG and WC events were characterized for 1st- and 2nd-lap splits using available footage from YouTube. Positive pacing strategies were defined as a faster 1st lap. Season's best 800-m time and world ranking, reflective of an athlete's "peak condition," were obtained to determine relationships between adopted tactics and physical condition prior to the championships. Seven championship events provided coverage of all medalists to enable determination of average 100-m speed and sector pacing of medalists. From 2011 onward, 800-m OG and WC medalists showed a faster 1st lap by 2.2 ± 1.1 s (mean, ±90% confidence limits; large difference, very likely), contrasting a possibly faster 2nd lap from 2000 to 2009 (0.5, ±0.4 s; moderate difference). A positive pacing strategy was related to a higher world ranking prior to the championships (r = .94, .84-.98; extremely large, most likely). After 2011, the fastest 100-m sector from 800-m OG and WC medalists was faster than before 2009 by 0.5, ±0.2 m/s (large difference, most likely). A secular change in tactical racing behavior appears evident in 800-m championships; since 2011, medalists have largely run faster 1st laps and have faster 100-m sector-speed requirements. This finding may be pertinent for training, tactical preparation, and talent identification of athletes preparing for 800-m running at OGs and WCs.

  11. Equilibrium states of the systems B-Cl-H and B-Cl-H-O at elevated temperatures

    International Nuclear Information System (INIS)

    Wagner, W.; Bochmann, G.

    1982-01-01

    By means of the computer program EHMSYS the equilibrium compositions are calculated in the reaction systems H 2 /BCl 3 and H 2 /BCl 3 /H 2 O with initial mixtures of 50, 25, 10, 5, 2, and 1 volume percent BCl 3 as well as initial volume portions of 0, 0.02, 0.05, 0.10, 0.25, and 0.50 volume percent gaseous water at temperatures of 800, 1000, 1200, and 1400 K. The results confirm the great complexity of the reaction system. The presence of oxygen causes the formation of gaseous B 3 H 3 O 3 and B 3 Cl 3 O 3 and in general a total suppression or at least a drastic decrease of the deposition of solid boron. Coincidentally, the amounts of gaseous haloboranes at the eqiulibrium are increased

  12. Harmonic Inverse FEL Interaction at 800nm

    CERN Document Server

    Sears, C M S; Siemann, R; Spencer, J E

    2005-01-01

    The inverse Free Electron Laser (IFEL) interaction has recently been proposed and demonstrated as a premodulator for High Gain Harmonic Generation (HGHG) experiments. These experiments utilized the fundamental of the interaction between the laser field and electron bunch. In the current experiment, we explore the higher order resonances of the IFEL interaction from a 3 period, 1.8 centimeter wavelength undulator with a picosecond, 0.25 mJ/pulse laser at 800nm. The resonances are observed by adjusting the gap of the undulator while keeping the beam energy constant. The harmonic IFEL can add flexibility to HGHG FEL design.

  13. 7 CFR 3017.800 - What are the causes for debarment?

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false What are the causes for debarment? 3017.800 Section... customers between competitors, and bid rigging; (3) Commission of embezzlement, theft, forgery, bribery... a debarment or suspension action; or (5) Violation of the provisions of the Drug-Free Workplace Act...

  14. Fuel component of electricity generation cost for the BN-800 reactor with 800 MOX fuel and uranium oxide fuel, increased fuel burnup, and removal of radial breeding blanket

    International Nuclear Information System (INIS)

    Raskach, A.

    2000-01-01

    There are two completed design concepts of NPP with BN-800 type reactors developed with due regard for enhanced safety requirements. They have been created for the 3 rd unit of Beloyarsk NPP and for three units of South Ural NPP. Both concepts are proposed to use mixed oxide fuel (MOX) based on civil plutonium. At this moment economical estimations carried out for these projects need to be revised in connection with the changes of economical situation in Russia and the world nuclear market structure. It is also essential to take into account the existing problem of the excess ex-weapons plutonium utilization and the possibility of using this plutonium to fabricate MOX fuel for the BN-800 reactors. (authors)

  15. 76 FR 78805 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2011-12-20

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... all Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines. This AD results from mandatory... inspection of the FOHE mounts. We did not change the AD based on this comment. Request To Add Requirement To...

  16. Microstructure studies of interdiffusion behavior of U{sub 3}Si{sub 2}/Zircaloy-4 at 800 and 1000 °C

    Energy Technology Data Exchange (ETDEWEB)

    He, Lingfeng, E-mail: Lingfeng.He@inl.gov; Harp, Jason M., E-mail: Jason.Harp@inl.gov; Hoggan, Rita E.; Wagner, Adrian R.

    2017-04-01

    Fuel swelling during normal reactor operations could lead to unfavorable chemical interactions when in contact with its cladding. As new fuel types are developed, it is crucial to understand the interaction behavior between fuel and its cladding. Diffusion experiments between U{sub 3}Si{sub 2} and Zricaloy-4 (Zry-4) were conducted at 800 and 1000 °C up to 100 h. The microstructure of pristine U{sub 3}Si{sub 2} and U{sub 3}Si{sub 2}/Zry-4 interdiffusion products were examined using scanning electron microscopy (SEM) and transmission electron microscopy (TEM) equipped with an energy dispersive X-ray spectroscopy (EDS) system. The primary interdiffusion product observed at 800 °C is ZrSi{sub 2}, with secondary phases of U-Zr in the Zry-4, and Fe-Cr-W-Zr-Si phases at Zry-4/ZrSi{sub 2} interface and Fe-Cr-U-Si phases at ZrSi{sub 2}/U-Si interface. The primary interdiffusion products at 1000 °C were Zr{sub 2}Si, U-Zr-Fe-Ni, U, U-Zr, and a low melting point phase U{sub 6}Fe.

  17. 34 CFR 85.800 - What are the causes for debarment?

    Science.gov (United States)

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false What are the causes for debarment? 85.800 Section 85... customers between competitors, and bid rigging; (3) Commission of embezzlement, theft, forgery, bribery... debarment or suspension action; or (5) Violation of the provisions of the Drug-Free Workplace Act of 1988...

  18. 800 kW transmission line research at Leatherhead

    Energy Technology Data Exchange (ETDEWEB)

    1964-05-29

    The experimental transmission line was installed at Leatherhead to enable the Central Electricity Research Laboratories to study the insulators, fittings, and conductors likely to be needed for ac power transmission at voltages up to the equivalent of 800 kV three-phase. Continuous recording will be made of corona power loss and radio and television interference. For this purpose C.E.R.L. has developed a statistical radio-interference recorder. The instrumentation also includes an automatic corona-loss bridge and data logger.

  19. Development of a procedure for estimating the high cycle fatigue strength of some high temperature structural alloys

    International Nuclear Information System (INIS)

    Soo, P.; Chow, J.G.Y.

    1979-01-01

    The generation of strain controlled fatigue data, for the standard strain rate of 4 x 10 -3 sec -1 , presents a problem when the cycles to failure exceed 10 5 because of the prohibitively long test times involved. In an attempt to circumvent this difficulty an evaluation has been made of a test procedure involving a fast cycling rate (40 Hz) and load controlled conditions. The validity of this procedure for extending current fatigue curves from 10 5 to 10 8 cycles and beyond, hinges upon the selection of an appropriate effective strain value, since the strain usually changes rapidly during the early stage of fatigue. Results from annealed 2 1/4 Cr-1 Mo, type 304 stainless steel, Incoloy 800H and Hastelloy X, tested over a wide range of temperatures, show that the strain measured N/sub f/2 is a reasonable estimate since it gives an excellent correlation between the strain and load controlled tests in the 10 5 cycle range where the data overlap. It seems clear that the differences in cycling rate and early stress-strain history for the two tests do not significantly affect the correlation. It may, therefore, be concluded that such load control test procedures may be used as a valid fast way for extending currently available fatigue curves from 10 5 to 10 8 cycles, and beyond

  20. Capture and dissociation in the complex-forming CH + H2 → CH2 + H, CH + H2 reactions.

    Science.gov (United States)

    González, Miguel; Saracibar, Amaia; Garcia, Ernesto

    2011-02-28

    The rate coefficients for the capture process CH + H(2)→ CH(3) and the reactions CH + H(2)→ CH(2) + H (abstraction), CH + H(2) (exchange) have been calculated in the 200-800 K temperature range, using the quasiclassical trajectory (QCT) method and the most recent global potential energy surface. The reactions, which are of interest in combustion and in astrochemistry, proceed via the formation of long-lived CH(3) collision complexes, and the three H atoms become equivalent. QCT rate coefficients for capture are in quite good agreement with experiments. However, an important zero point energy (ZPE) leakage problem occurs in the QCT calculations for the abstraction, exchange and inelastic exit channels. To account for this issue, a pragmatic but accurate approach has been applied, leading to a good agreement with experimental abstraction rate coefficients. Exchange rate coefficients have also been calculated using this approach. Finally, calculations employing QCT capture/phase space theory (PST) models have been carried out, leading to similar values for the abstraction rate coefficients as the QCT and previous quantum mechanical capture/PST methods. This suggests that QCT capture/PST models are a good alternative to the QCT method for this and similar systems.

  1. The origin of the split B800 absorption peak in the LH2 complexes from Allochromatium vinosum.

    Science.gov (United States)

    Löhner, Alexander; Carey, Anne-Marie; Hacking, Kirsty; Picken, Nichola; Kelly, Sharon; Cogdell, Richard; Köhler, Jürgen

    2015-01-01

    The absorption spectrum of the high-light peripheral light-harvesting (LH) complex from the photosynthetic purple bacterium Allochromatium vinosum features two strong absorptions around 800 and 850 nm. For the LH2 complexes from the species Rhodopseudomonas acidophila and Rhodospirillum molischianum, where high-resolution X-ray structures are available, similar bands have been observed and were assigned to two pigment pools of BChl a molecules that are arranged in two concentric rings (B800 and B850) with nine (acidophila) or eight (molischianum) repeat units, respectively. However, for the high-light peripheral LH complex from Alc. vinosum, the intruiging feature is that the B800 band is split into two components. We have studied this pigment-protein complex by ensemble CD spectroscopy and polarisation-resolved single-molecule spectroscopy. Assuming that the high-light peripheral LH complex in Alc. vinosum is constructed on the same modular principle as described for LH2 from Rps. acidophila and Rsp. molischianum, we used those repeat units as a starting point for simulating the spectra. We find the best agreement between simulation and experiment for a ring-like oligomer of 12 repeat units, where the mutual arrangement of the B800 and B850 rings resembles those from Rsp. molischianum. The splitting of the B800 band can be reproduced if both an excitonic coupling between dimers of B800 molecules and their interaction with the B850 manifold are taken into account. Such dimers predict an interesting apoprotein organisation as discussed below.

  2. 78 FR 42526 - Compliance Policy Guide Sec. 690.800 Salmonella

    Science.gov (United States)

    2013-07-16

    ... food for animals. It does not create or confer any rights for or on any person and does not operate to...] Compliance Policy Guide Sec. 690.800 Salmonella in Food for Animals; Availability AGENCY: Food and Drug... Animals'' (the CPG). The CPG provides guidance to FDA staff on Salmonella-contaminated food for animals...

  3. Assessment of effects of Fort St. Vrain HTGR primary coolant on Alloy 800. Final report

    International Nuclear Information System (INIS)

    Trester, P.W.; Johnson, W.R.; Simnad, M.T.; Burnette, R.D.; Roberts, D.I.

    1982-08-01

    A comprehensive review was conducted of primary helium coolant chemistry data, based on current and past operating histories of helium-cooled, high-temperature reactors (HTGRs), including the Fort St. Vrain (FSV) HTGR. A reference observed FSV reactor coolant environment was identified. Further, a slightly drier expected FSV coolant chemistry was predicted for reactor operation at 100% of full power. The expected environment was compared with helium test environments used in the US, United Kingdom, Germany, France, and Japan. Based on a comprehensive review and analysis of mechanical property data reported for Alloy 800 tested in controlled-impurity helium environments (and in air when appropriate for comparison), an assessment was made of the effect of FSV expected helium chemistry on material properties of alloy 800, with emphasis on design properties of the Alloy 800 material utilized in the FSV steam generators

  4. 2 CFR 180.800 - What are the causes for debarment?

    Science.gov (United States)

    2010-01-01

    ... 2 Grants and Agreements 1 2010-01-01 2010-01-01 false What are the causes for debarment? 180.800..., theft, forgery, bribery, falsification or destruction of records, making false statements, tax evasion... the provisions of the Drug-Free Workplace Act of 1988 (41 U.S.C. 701); or (d) Any other cause of so...

  5. 29 CFR 1471.800 - What are the causes for debarment?

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false What are the causes for debarment? 1471.800 Section 1471...) Commission of embezzlement, theft, forgery, bribery, falsification or destruction of records, making false...) Violation of the provisions of the Drug-Free Workplace Act of 1988 (41 U.S.C. 701); or (d) Any other cause...

  6. Deposition of magnetite particles onto alloy-800 steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Basset, M.; Arbeau, N.; McInerney, J.; Lister, D.H. [Univ. of New Brunswick, Dept. of Chemical Engineering, Fredericton, NB (Canada)

    1998-07-01

    Fouling is a particularly serious problem in the power generating industry. Deposits modify the thermalhydraulic characteristics of heat transfer surfaces by changing the resistance to heat transfer and the resistance to fluid flow, and, if thick enough, can harbour aggressive chemicals. Deposits are also implicated in the increase of radiation fields around working areas in the primary heat transfer systems of nuclear power plants. In order to understand the preliminary steps of the formation of corrosion product deposits on the outsides of steam generator tubes, a laboratory program has investigated the deposition of magnetite particles from suspension in water onto Alloy-800 surfaces under various conditions of flow, chemistry and boiling heat transfer. A recirculating loop made of stainless steel operating at less than 400kPa pressure, with a nominal coolant temperature of 90 degrees C, was equipped with a vertical glass column which housed a 2.5E-01m-long Alloy-800 boiler tube capable of generating a heat flux of 240kW/m{sup 2} . A concentration of suspended magnetite of 5.0E-03kg/m{sup 3} was maintained in the recirculating coolant, which was maintained at a pH of 7.5. The magnetite was synthesized with a sol-gel process, which was developed to produce reproducibly monodispersed, colloidal (<1{mu}m) and nearly spherical particles. A radiotracing method was used to characterize the deposit evolution with time and to quantify the removal of magnetite particles. The results from a series of deposition experiments are presented here. The deposition process is described in terms of a two-step mechanism: the transport step, involving the transport from the bulk of the liquid to the vicinity of the surface, followed by the attachment step, involving the attachment of the particle onto the surface. Under non-boiling heat transfer conditions, diffusion seems to be the dominant factor ruling deposition with a small contribution from thermophoresis; removal was

  7. Deposition of magnetite particles onto alloy-800 steam generator tubes

    International Nuclear Information System (INIS)

    Basset, M.; Arbeau, N.; McInerney, J.; Lister, D.H.

    1998-01-01

    Fouling is a particularly serious problem in the power generating industry. Deposits modify the thermalhydraulic characteristics of heat transfer surfaces by changing the resistance to heat transfer and the resistance to fluid flow, and, if thick enough, can harbour aggressive chemicals. Deposits are also implicated in the increase of radiation fields around working areas in the primary heat transfer systems of nuclear power plants. In order to understand the preliminary steps of the formation of corrosion product deposits on the outsides of steam generator tubes, a laboratory program has investigated the deposition of magnetite particles from suspension in water onto Alloy-800 surfaces under various conditions of flow, chemistry and boiling heat transfer. A recirculating loop made of stainless steel operating at less than 400kPa pressure, with a nominal coolant temperature of 90 degrees C, was equipped with a vertical glass column which housed a 2.5E-01m-long Alloy-800 boiler tube capable of generating a heat flux of 240kW/m 2 . A concentration of suspended magnetite of 5.0E-03kg/m 3 was maintained in the recirculating coolant, which was maintained at a pH of 7.5. The magnetite was synthesized with a sol-gel process, which was developed to produce reproducibly monodispersed, colloidal (<1μm) and nearly spherical particles. A radiotracing method was used to characterize the deposit evolution with time and to quantify the removal of magnetite particles. The results from a series of deposition experiments are presented here. The deposition process is described in terms of a two-step mechanism: the transport step, involving the transport from the bulk of the liquid to the vicinity of the surface, followed by the attachment step, involving the attachment of the particle onto the surface. Under non-boiling heat transfer conditions, diffusion seems to be the dominant factor ruling deposition with a small contribution from thermophoresis; removal was considered

  8. BN-800 as a new stage in development of fast neutron sodium cooled reactors

    International Nuclear Information System (INIS)

    Poplavskij, V.M.; Chebeskov, A.N.; Matveev, V.I.

    2004-01-01

    The role of fast reactors in the strategy of evolution of the nuclear power of Russia is discussed, BN-800 under construction, where unique technical and construction decisions are used, is viewed. Economical estimations of expenses with regard for all life cycle demonstrate that fast reactors may be no higher-priced than the most popular in the world water moderated reactors. Closing of nuclear fuel cycle of BN-800 makes possible decision of the problem of plutonium and actinide utilization, that makes the fast reactor more safety for the environment [ru

  9. Intraoperative Detection of Cell Injury and Cell Death with an 800 nm Near-Infrared Fluorescent Annexin V Derivative

    Science.gov (United States)

    Ohnishi, Shunsuke; Vanderheyden, Jean-Luc; Tanaka, Eiichi; Patel, Bhavesh; De Grand, Alec; Laurence, Rita G.; Yamashita, Kenichiro; Frangioni, John V.

    2008-01-01

    The intraoperative detection of cell injury and cell death is fundamental to human surgeries such as organ transplantation and resection. Because of low autofluorescence background and relatively high tissue penetration, invisible light in the 800 nm region provides sensitive detection of disease pathology without changing the appearance of the surgical field. In order to provide surgeons with real-time intraoperative detection of cell injury and death after ischemia/reperfusion (I/R), we have developed a bioactive derivative of human annexin V (annexin800), which fluoresces at 800 nm. Total fluorescence yield, as a function of bioactivity, was optimized in vitro, and final performance was assessed in vivo. In liver, intestine and heart animal models of I/R, an optimal signal to background ratio was obtained 30 min after intravenous injection of annexin800, and histology confirmed concordance between planar reflectance images and actual deep tissue injury. In summary, annexin800 permits sensitive, real-time detection of cell injury and cell death after I/R in the intraoperative setting, and can be used during a variety of surgeries for rapid assessment of tissue and organ status. PMID:16869796

  10. Acquisition and Initial Analysis of H+- and H--Beam Centroid Jitter at LANSCE

    Science.gov (United States)

    Gilpatrick, J. D.; Bitteker, L.; Gulley, M. S.; Kerstiens, D.; Oothoudt, M.; Pillai, C.; Power, J.; Shelley, F.

    2006-11-01

    During the 2005 Los Alamos Neutron Science Center (LANSCE) beam runs, beam current and centroid-jitter data were observed, acquired, analyzed, and documented for both the LANSCE H+ and H- beams. These data were acquired using three beam position monitors (BPMs) from the 100-MeV Isotope Production Facility (IPF) beam line and three BPMs from the Switchyard transport line at the end of the LANSCE 800-MeV linac. The two types of data acquired, intermacropulse and intramacropulse, were analyzed for statistical and frequency characteristics as well as various other correlations including comparing their phase-space like characteristics in a coordinate system of transverse angle versus transverse position. This paper will briefly describe the measurements required to acquire these data, the initial analysis of these jitter data, and some interesting dilemmas these data presented.

  11. Influence of acidic pH on hydrogen and acetate production by an electrosynthetic microbiome.

    Directory of Open Access Journals (Sweden)

    Edward V LaBelle

    Full Text Available Production of hydrogen and organic compounds by an electrosynthetic microbiome using electrodes and carbon dioxide as sole electron donor and carbon source, respectively, was examined after exposure to acidic pH (∼ 5. Hydrogen production by biocathodes poised at -600 mV vs. SHE increased >100-fold and acetate production ceased at acidic pH, but ∼ 5-15 mM (catholyte volume/day acetate and >1,000 mM/day hydrogen were attained at pH ∼ 6.5 following repeated exposure to acidic pH. Cyclic voltammetry revealed a 250 mV decrease in hydrogen overpotential and a maximum current density of 12.2 mA/cm2 at -765 mV (0.065 mA/cm2 sterile control at -800 mV by the Acetobacterium-dominated community. Supplying -800 mV to the microbiome after repeated exposure to acidic pH resulted in up to 2.6 kg/m3/day hydrogen (≈ 2.6 gallons gasoline equivalent, 0.7 kg/m3/day formate, and 3.1 kg/m3/day acetate ( = 4.7 kg CO2 captured.

  12. Corrosion behaviour of Alloy 800 in high temperature aqueous solutions: Electrochemical studies

    International Nuclear Information System (INIS)

    Olmedo, A.M.; Villegas, M.; Alvarez, M.G.

    1996-01-01

    The anodic behaviour and passivity breakdown of Alloy 800 in aqueous solutions of sodium chloride, sodium sulphate and sodium bicarbonate were studied by electrochemical techniques in the temperature range from 60 C to 280 C. The pitting resistance and pitting morphology of the alloy in chloride plus sulphate and chloride plus bicarbonate mixtures, at 60 C and 280 C, were also examined. Increasing bicarbonate or sulphate additions to chloride solutions shift the characteristic pitting potential of Alloy 800 to higher values, both at low and high temperatures. Changes in pitting morphology were observed in sulphate containing solutions while the morphology of the attack found in bicarbonate containing solutions was similar to that in pure chloride solutions. Finally, no localized or substantial generalized corrosion was detected in pure sulphate or bicarbonate solutions at any temperature. (orig.)

  13. Comparison of French and German NPP water chemistry programs

    International Nuclear Information System (INIS)

    Staudt, U.; Odar, S.; Stutzmann, A.

    2002-01-01

    PWRs in the western hemisphere obey basically the same rules concerning design, choice of material and operational mode. In spite of these basic similarities, the manufacturers of PWRs in different countries developed different solutions in respect to single components in the steam/water cycle. Looking specifically at France and Germany, the difference in the tubing material of the steam generators (Inconel 600/690 chosen by Framatome and Incoloy 800 chosen by the former Siemens KWU) led to specific differences in the respective chemistry programs and in some respect to different 'philosophies' in operating the water/steam cycle. Compared to this, basic differences in operating the reactor coolant system cannot be observed. Nevertheless specific solutions as zinc injection and the use of enriched B-10 are applied in German PWRs. The application of such measures arises from a specific dose rate situation in older PWRs (zinc injection) or from economic reasons mainly (B-10). (authors)

  14. Tritium permeation through helium-heated steam generators of ceramic breeder blankets for DEMO

    International Nuclear Information System (INIS)

    Fuetterer, M.A.; Raepsaet, X.; Proust, E.

    1994-01-01

    The specifications of permeation barriers, tritium recovery process maintaining a very low tritium activity in the coolant, and control of the coolant chemistry, required the evaluation of the tritium losses through the steam generators and include the definition of its operating conditions by thermodynamic cycle calculations and its thermal-hydraulic design. For both tasks specific computer tools were developed. The obtained geometry, surface area, and temperature profiles along the heat exchanger tubes were then used to estimate the daily tritium permeation into the steam cycle. Steam oxidized Incoloy 800 austenitic stainless steel was identified as the best suited existing material; in nominal steady-state operation, the tritium escape into the steam cycle could be restricted to less than 10 Ci/d. Tritium permeation during temperature and pressure transients in the steam generator (destruction and possible self-healing of the permeation barrier) is identified to bear a large tritium release potential. Solutions are proposed. (from authors). 4 figs., 1 tab

  15. Tritium permeation through helium-heated steam generators of ceramic breeder blankets for DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Fuetterer, M A; Raepsaet, X; Proust, E

    1994-12-31

    The specifications of permeation barriers, tritium recovery process maintaining a very low tritium activity in the coolant, and control of the coolant chemistry, required the evaluation of the tritium losses through the steam generators and include the definition of its operating conditions by thermodynamic cycle calculations and its thermal-hydraulic design. For both tasks specific computer tools were developed. The obtained geometry, surface area, and temperature profiles along the heat exchanger tubes were then used to estimate the daily tritium permeation into the steam cycle. Steam oxidized Incoloy 800 austenitic stainless steel was identified as the best suited existing material; in nominal steady-state operation, the tritium escape into the steam cycle could be restricted to less than 10 Ci/d. Tritium permeation during temperature and pressure transients in the steam generator (destruction and possible self-healing of the permeation barrier) is identified to bear a large tritium release potential. Solutions are proposed. (from authors). 4 figs., 1 tab.

  16. Determination of safety margins for creep loaded primary circuit components in case of loss of pressure accidents of a HTR plant (SR 383)

    International Nuclear Information System (INIS)

    Breitbach, G.; Ahmed, K.; Over, H.; Schubert, F.; Nickel, H.

    1991-10-01

    The wall thickness of tubes in high temperature plants must be limited in such a way that pressure differences can not produce unadmissible deformations. For HTR (PNP-Plant) the postulated loss of secondary pressure is one of the considered accidents. In that case the tubes of the heat exchangers are loaded by the outher pressure of the primary coolant. So the risk of a creep collapse is given. The report is related to experimental and theoretical work for the creep collapse phenomena. HTR relevant tube geometries of the high temperature alloys NiCr22Co12Mo (INCONEL 617) and X10NiCrAlTi 32 20 (INCOLOY 800) were tested at temperatures of 900 and 950deg C and outer pressure loads in the range 40 bars. The experimental results are compared with theoretically computed values and discussed. The problem of safety margin is treated. Further, simplified procedures are developed for the estimation of the collapse time. (orig.) [de

  17. Temperature measurement: Development work on noise thermometry and improvement of conventional thermocouples for applications in nuclear process heat (PNP)

    International Nuclear Information System (INIS)

    Brixy, H.; Hecker, R.; Oehmen, J.; Barbonus, P.; Hans, R.

    1982-06-01

    The behaviour was studied of NiCr-Ni sheathed thermocouples (sheath Inconel 600 or Incoloy 800, insulation MgO) in a helium and carbon atmosphere at temperatures of 950-1150 deg. C. All the thermocouples used retained their functional performance. The insulation resistance tended towards a limit value which is dependent on the temperature and quality of the thermocouple. Temperature measurements were loaded with great uncertainty in the temperature range of 950-1150 deg. C. Recalibrations at the temperature of 950 deg. C showed errors of up to 6%. Measuring sensors were developed which consist of a sheathed double thermocouple with a noise resistor positioned between the two hot junctions. Using the noise thermometer it is possible to recalibrate the thermocouple at any time in situ. A helium system with a high temperature experimental area was developed to test the thermocouples and the combined thermocouple-noise thermometer sensors under true experimental conditions

  18. Comparison of French and German NPP water chemistry programs

    Energy Technology Data Exchange (ETDEWEB)

    Staudt, U. [VGB Powertech (Germany); Odar, S. [Framatome ANP GmbH (Germany); Stutzmann, A. [EDF/GDL (France)

    2002-07-01

    PWRs in the western hemisphere obey basically the same rules concerning design, choice of material and operational mode. In spite of these basic similarities, the manufacturers of PWRs in different countries developed different solutions in respect to single components in the steam/water cycle. Looking specifically at France and Germany, the difference in the tubing material of the steam generators (Inconel 600/690 chosen by Framatome and Incoloy 800 chosen by the former Siemens KWU) led to specific differences in the respective chemistry programs and in some respect to different 'philosophies' in operating the water/steam cycle. Compared to this, basic differences in operating the reactor coolant system cannot be observed. Nevertheless specific solutions as zinc injection and the use of enriched B-10 are applied in German PWRs. The application of such measures arises from a specific dose rate situation in older PWRs (zinc injection) or from economic reasons mainly (B-10). (authors)

  19. 75 FR 66769 - Draft Compliance Policy Guide Sec. 690.800 Salmonella

    Science.gov (United States)

    2010-10-29

    ...] Draft Compliance Policy Guide Sec. 690.800 Salmonella in Animal Feed; Availability; Extension of Comment... that are adulterated due to the presence of Salmonella. The Agency is taking this action in response to... action against animal feed or feed ingredients that are adulterated due to the presence of Salmonella...

  20. Characterization of the SPS 800MHz travelling wave cavities.

    CERN Document Server

    Bazyl, Dmitry

    2015-01-01

    It is well known that HOMs in RF cavities are a potentially dangerous source of beam impedance. Therefore, HOMs (both longitudinal and transverse) can drive the beam unstable . The 800MHz cavities of the SPS were studied in the past. However, very little documentation was left behind. Currently, the performance of the SPS is limited by a longitudinal beam instability. In order to study this instability, an accurate impedance model of the whole SPS is needed.

  1. High-Temperature Corrosion of T92 Steel in N{sub 2}/H{sub 2}O/H{sub 2}S-Mixed Gas

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Yuke; Kim, Min Jung; Park, Soon Yong; Abro, M. Ali; Yadav, Poonam; Lee, Dong Bok [Sungkyunkwan University, Suwon (Korea, Republic of)

    2016-06-15

    The ASTM T92 steel was corroded at 600 ℃ and 800 ℃ at 1 atm of N{sub 2}/3.1%H{sub 2}O/2.42%H{sub 2}S-mixed gas. The formed scales were thick and fragile. They consisted primarily of the outer FeS scale and the inner (FeS, FeCr{sub 2}S{sub 4})-mixed scale containing a small amount of the Cr{sub 2}O{sub 3} scale. This indicated that corrosion occurred mainly via sulfidation rather than oxidation due to the H{sub 2}S gas. Since FeS was present throughout the whole scale, T92 steel was non-protective, displaying high corrosion rates.

  2. 13 CFR 108.800 - Financings in the form of equity interests.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Financings in the form of equity... VENTURE CAPITAL (âNMVCâ) PROGRAM Financing of Small Businesses by NMVC Companies Structuring Nmvc Company's Financing of Eligible Small Businesses § 108.800 Financings in the form of equity interests. You...

  3. Degradation of Alloy 800 steam generator tubing and its long-term behaviour predictions for plant life management

    International Nuclear Information System (INIS)

    Lu, Y.C.; Tapping, R.L.; Pandey, M.D.

    2009-01-01

    Alloy 800 tubing has a good service record in steam generators (SGs) in both German pressurized water reactors and CANDU 6 reactors, however, a recent comprehensive examination of several ex-service SG tubes removed from Darlington Nuclear Generating Station (DNGS) found that these SG tubes (which had experienced shallow pitting in service) were more susceptible to pitting corrosion in laboratory tests than a reference nuclear grade Alloy 800 tubing under SG crevice chemistry conditions. This was an unexpected finding and has raised questions about possible effects of in-service 'aging' on SG tubing. In addition, there has also been recent evidence that a few Alloy 800 tubes have experienced stress corrosion cracking (SCC) in some German pressurized water reactors (PWRs), possibly after many years of degradation-free service, although the inspection history of these tubes is not available to confirm that the reported degradation initiated recently. These findings suggest that Alloy 800 tubing may have some aging degradation susceptibility after many years of service. To provide support for a proactive SG aging management, a survey on the corrosion susceptibility of the archived Alloy 800 tubing from CANDU SGs under plausible crevice chemistry conditions was conducted to assess the potential material degradation issues in CANDU SGs. Experimental work was also performed to investigate the root cause leading to Alloy 800 SG tubing degradation. The results from this study suggested that a combination of negative factors; aggressive chemistry resulting from impurity ingress into the secondary side of the SGs, elevated electrochemical corrosion potential (ECP) during SG transients and surface strain/plastic deformation, might have led to the degradation of the ex-service SG tubing. The studies have shown that each of these conditions in isolation does not cause degradation of Alloy 800 SG tubing; a synergistic combination of factors is required. The OPEX and experimental

  4. The influence of the water chemistry regime of the third circuit on the corrosion hydrogen burden to the secondary sodium circuit in the steam generator model of BN-800 reactor

    International Nuclear Information System (INIS)

    Smykov, V.B.; Ermolaev, N.P.; Kolesnik, A.I.; Egorov, V.A.; Shevchenko, N.N.

    1994-01-01

    An experimental program was conducted to determine the influence of water chemistry on the corrosion hydrogen burden from the III circuit to the secondary sodium in sodium-heated rig of OTSG of NPP BN-800. Combined water chemistry has given the best passivative effect on steam-generating surfaces and smallest hydrogen burden to secondary sodium during start-up. Common hydrogen increasing in secondary sodium was less then 0.2 ppm. In case of AVT water chemistry (NH 3 +N 2 H 4 ) in III side of OTSG-rig the hydrogen level in secondary sodium was 1.0-1.2 ppm. It means that during first start-up at NPP BN-800 the common hydrogen level in secondary sodium may reaches 0.80-0.85 ppm. 4 figs.; 4 tabs

  5. High power test of low enriched UZrH

    Energy Technology Data Exchange (ETDEWEB)

    West, Gordon [General Atomic Co., San Diego, CA (United States)

    1980-07-01

    TRIGA-LEU fuel is currently undergoing high power tests in the 30 MW Oak Ridge Reactor. These tests are being funded by the Department of Energy through the RERTR program [Reduced Enrichment Research and Test Reactor program administered by Argonne National Laboratory] and began in mid-December, 1979 on a 16-rod shrouded cluster. The fuel rods are 0.51 in. 0D, clad with 0.16 in. Incoloy and the fuel length is 22 in. It is planned to test the UZrH fuel with 45, 30 and 20 wt-% U (nominal 20% enriched), to burnup values of about 50% of the contained U-235 in the 45 wt-% rods and about 40% and 35% burnup in the 30 wt-%, and 20 wt-% U fuel. It will take about 2 years of irradiation to produce the desired burnup in the 45 wt-% U fuel. Currently being tested are six 45 wt-% U and five 30 wt-% U rods. The remaining 5 rods are stainless steel dummies which were necessary to meet an operational requirement of the ORR which limits the power generation in a fuel rod to a value which would not raise the coolant temperature above the saturation level. Maximum calculated fuel rod powers were 40 kW, which would produce a fuel temperature of about 650 deg. C. The measured temperatures are about 400 deg. C and 350 deg. C for the 45 and 30 wt-% U fuel, respectively. Flow and {delta}T measurements show the cluster power generation to be about 250 kW, or about 65% of the design value. Reasons for the lower than expected power are still being evaluated and a proposal has been submitted for rearrangement of the fuel rods within the cluster to raise the powers and temperatures in the TRIGA-LEU fuel rods. (author)

  6. Enhancement of 800 nm upconversion emission in a thulium doped tellurite microstructured fiber pumped by a 1560 nm femtosecond fiber laser

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Zhixu; Zheng, Kezhi [State Key Laboratory of Optical Fiber and Cable Manufacture Technology, Yangtze Optical Fiber and Cable Joint Stock Limited Company, Wuhan 430073 (China); State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012 (China); Yao, Chuanfei; Wang, Shunbin; Qin, Guanshi, E-mail: qings@jlu.edu.cn; Qin, Weiping, E-mail: wpqin@jlu.edu.cn [State Key Laboratory on Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun 130012 (China); Xiong, Liangming; Luo, Jie; Lv, Dajuan [State Key Laboratory of Optical Fiber and Cable Manufacture Technology, Yangtze Optical Fiber and Cable Joint Stock Limited Company, Wuhan 430073 (China); Ohishi, Yasutake [Research Center for Advanced Photon Technology, Toyota Technological Institute, 2-12-1 Hisakata, Tempaku, Nagoya 468–8511 (Japan)

    2016-04-28

    We report enhanced upconversion (UC) fluorescence in Tm{sup 3+} doped tellurite microstructured fibers (TDTMFs) fabricated by using a rod-in-tube method. Under the pumping of a 1560 nm femtosecond fiber laser, ultrabroadband supercontinuum light expanding from ∼1050 to ∼2700 nm was generated in a 4 cm long TDTMF. Simultaneously, intense 800 nm UC emission from the {sup 3}H{sub 4} → {sup 3}H{sub 6} transition of Tm{sup 3+} was observed in the same TDTMF. Compared to that pumped by a 1560 nm continuous wave fiber laser, the UC emission intensity was enhanced by ∼4.1 times. The enhancement was due to the spectral broadening in the TDTMF under the pumping of the 1560 nm femtosecond fiber laser.

  7. Laidoneri-Savisaare villa hinnati juba 2003. aastal 800 000 kroonile / Martti Kass

    Index Scriptorium Estoniae

    Kass, Martti

    2005-01-01

    Edgar Savisaare firma ostetud suvila Keila-Joal oli 2003. aastal Arco Vara hinnangul väärt 800 000 krooni. Kinnisvaraekspertide hinnangul on Keila-Joa kinnisvara väärtus viimaste aastatega mitu korda suurenenud. Lisa: Ojulandi ja Käo maja hinnati 3,25 miljonile

  8. Adsorption of CO, CO2, H2, and H2O on titania surfaces with different oxidation states

    International Nuclear Information System (INIS)

    Raupp, G.B.; Dumesic, J.A.

    1985-01-01

    The adsorptive properties of titania surfaces with different oxidation states were proved by temperature-programmed desorption (TPD) of CO, H 2 , CO 2 , and H 2 O. Auger electron spectroscopy and X-ray photoelectron spectroscopy revealed that vacuum annealing an oxidized titanium foil at temperatures from 300 to 800 K was an effective means of systematically varying the average surface oxidation state from Ti 4+ to Ti 2+ . Carbon monoxide weakly adsorbed (desorption energy of 44-49 kJ x mol -1 ) in a carbonyl fashion on coordinatively unsaturated cation sites. Titania surfaces were inert with respect to H 2 adsorption and dissociation. Carbon dioxide adsorbed in a linear molecular fashion. Water adsorbed both molecularly and dissociatively. Results are discussed in terms of the role of titania oxidation state in CO hydrogenation over titania-supported metal catalysts. 74 references, 7 figures

  9. Comparative study of oxalic and malonic acid behaviour in the chemical cleaning of alloy 800 surfaces

    International Nuclear Information System (INIS)

    Garcia, Damian A.; Bruyere, Vivienne I.E.; Bordoni, Roberto A.; Olmedo, Ana M.; Morando, Pedro J.

    2004-01-01

    This work consisted, in a first stage, on a basic study of the dissolution mechanism of nickel ferrite in aqueous malonic acid. Powdered oxides (Ni x Fe 3-x O 4 ) were synthesized by wet procedures and heated at 750 C degrees. These oxides were characterized by conventional methods and dissolved under different experimental conditions (pH, reagent concentration, temperature, etc.) in order to determine the dissolution rates. Optimal dissolution conditions were explored and compared to the corresponding oxalic acid ones. In a second stage, these conditions were applied to oxides grown on Alloy 800 coupons. Before oxidation, all coupons were ground polished and then were exposed to hydrothermal conditions (350 C degrees, pH 25Cdegrees ≅ 10.4 -LiOH-, 20-22 days) in static autoclaves. Finally, oxidized and unoxidized coupons were treated with chemical solutions containing oxalic or malonic acid at conditions optimized in the first stage. These results were also compared to those obtained on coupons exposed to a commercial formulation, APAC (Alkaline Permanganate Ammonium Citrate), as a reference. The results on coupon descaling using APMAL (AP + Malonic), APOX (AP + oxalic) and the comparison with APAC leads to conclude that malonic acid is a reagent whose chemical behavior is much better than oxalic acid and comparable to commercial formulations. (author) [es

  10. Orbital and millennial Antarctic climate variability over the past 800,000 years

    DEFF Research Database (Denmark)

    Jouzel, J.; Masson-Delmotte, V.; Cattani, O.

    2007-01-01

    A high-resolution deuterium profile is now available along the entire European Project for Ice Coring in Antarctica Dome C ice core, extending this climate record back to marine isotope stage 20.2, 800,000 years ago. Experiments performed with an atmospheric general circulation model including wa...

  11. High-Temperature Test of 800HT Printed Circuit Heat Exchanger in HELP

    International Nuclear Information System (INIS)

    Kim, Chan Soo; Hong, Sung-Deok; Kim, Min Hwan; Shim, Jaesool

    2014-01-01

    Korea Atomic Energy Research Institute has developed high-temperature Printed Circuit Heat Exchangers (PCHE) for a Very High Temperature gas-cooled Reactor and operated a very high temperature Helium Experimental LooP (HELP) to verify the performance of the high temperature heat exchanger at the component level environment. PCHE is one of the candidates for the intermediate heat exchanger in a VHTR, because its design temperature and pressure are larger than any other compact heat exchanger types. High temperature PCHEs in HELP consist of an alloy617 PCHE and an 800HT PCHE. This study presents the high temperature test of an 800HT PCHE in HELP. The experimental data include the pressure drops, the overall heat transfer coefficients, and the surface temperature distributions under various operating conditions. The experimental data are compared with the thermo-hydraulic analysis from COMSOL. In addition, the single channel tests are performed to quantify the friction factor under normal nitrogen and helium inlet conditions. (author)

  12. 78 FR 42701 - Improving Public Safety Communications in the 800 MHz Band

    Science.gov (United States)

    2013-07-17

    ...] Improving Public Safety Communications in the 800 MHz Band AGENCY: Federal Communications Commission. ACTION...-901 MHz/935- 940 MHz band (900 MHz B/ILT Band) to allow a qualified entity to file an application for..., manufacturing, energy) to non-commercial (e.g., clerical, educational, philanthropic, medical). In 2004, the...

  13. Microstructural Effects on Hydrogen Delayed Fracture of 600 MPa and 800 MPa grade Deposited Weld Metal

    International Nuclear Information System (INIS)

    Kang, Hee Jae; Lee, Tae Woo; Cho, Kyung Mox; Kang, Namhyun; Yoon, Byung Hyun; Park, Seo Jeong; Chang, Woong Seong

    2012-01-01

    Hydrogen-delayed fracture (HDF) was analyzed from the deposited weld metals of 600-MPa and 800-MPa flux-cored arc (FCA) welding wires, and then from the diffusible hydrogen behavior of the weld zone. Two types of deposited weld metal, that is, rutile weld metal and alkali weld metal, were used for each strength level. Constant loading test (CLT) and thermal desorption spectrometry (TDS) analysis were conducted on the hydrogen pre-charged specimens electrochemically for 72 h. The effects of microstructures such as acicular ferrite, grain-boundary ferrite, and low-temperature-transformation phase on the time-to failure and amount of diffusible hydrogen were analyzed. The fracture time for hydrogen-purged specimens in the constant loading tests decreased as the grain size of acicular ferrite decreased. The major trapping site for diffusible hydrogen was the grain boundary, as determined by calculating the activation energies for hydrogen detrapping. As the strength was increased and alkali weld metal was used, the resistance to HDF decreased.

  14. Submicrosecond linear pulse transformer for 800 kV voltage with modular low-inductance primary power supply

    Energy Technology Data Exchange (ETDEWEB)

    Bykov, Yu. A.; Krastelev, E. G., E-mail: ekrastelev@yandex.ru; Popov, G. V.; Sedin, A. A.; Feduschak, V. F. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2016-12-15

    A pulsed power source with voltage amplitude up to 800 kV for fast charging (350–400 ns) of the forming line of a high-current nanosecond accelerator is developed. The source includes capacitive energy storage and a linear pulse transformer. The linear transformer consists of a set of 20 inductors with circular ferromagnetic cores surrounded by primary windings inside of which a common stock adder of voltage with film-glycerol insulation is placed. The primary energy storage consists of ten modules, each of which is a low-inductance assembly of two capacitors with a capacitance of 0.35 μF and one gas switch mounted in the same frame. The total energy stored in capacitors is 5.5 kJ at the operating voltage of 40 kV. According to test results, the parameters of the equivalent circuit of the source are the following: shock capacitance = 17.5 nF, inductance = 2 μH, resistance = 3.2 Ω.

  15. 21 CFR 800.12 - Contact lens solutions and tablets; tamper-resistant packaging.

    Science.gov (United States)

    2010-04-01

    ... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800... packer who packages for retail sale a product regulated as a medical device that is a solution intended... bottle with a shrink band could say “For your protection, this bottle has an imprinted seal around the...

  16. Comparison of higher order modes damping techniques for 800 MHz single cell superconducting cavities

    Energy Technology Data Exchange (ETDEWEB)

    Shashkov, Ya.V., E-mail: shashkovyv@mail.ru [National Research Nuclear University MEPhI, Moscow (Russian Federation); Sobenin, N.P.; Petrushina, I.I. [National Research Nuclear University MEPhI, Moscow (Russian Federation); Zobov, M.M. [Laboratori Nazionali di Frascati INFN, Rome (Italy)

    2014-12-11

    At present, applications of 800 MHz harmonic cavities in both bunch lengthening and shortening regimes are under consideration and discussion in the framework of the High Luminosity LHC project. In this paper we study electromagnetic characteristics of high order modes (HOMs) for a single cell 800 MHz superconducting cavity and arrays of such cavities connected by drifts tubes. Different techniques for the HOMs damping such as beam pipe grooves, coaxial-notch loads, fluted beam pipes etc. are investigated and compared. The influence of the sizes and geometry of the drift tubes on the HOMs damping is analyzed. The problems of a multipacting discharge in the considered structures are discussed and the operating frequency detuning due to the Lorentz force is evaluated.

  17. Comparison of higher order modes damping techniques for 800 MHz single cell superconducting cavities

    Science.gov (United States)

    Shashkov, Ya. V.; Sobenin, N. P.; Petrushina, I. I.; Zobov, M. M.

    2014-12-01

    At present, applications of 800 MHz harmonic cavities in both bunch lengthening and shortening regimes are under consideration and discussion in the framework of the High Luminosity LHC project. In this paper we study electromagnetic characteristics of high order modes (HOMs) for a single cell 800 MHz superconducting cavity and arrays of such cavities connected by drifts tubes. Different techniques for the HOMs damping such as beam pipe grooves, coaxial-notch loads, fluted beam pipes etc. are investigated and compared. The influence of the sizes and geometry of the drift tubes on the HOMs damping is analyzed. The problems of a multipacting discharge in the considered structures are discussed and the operating frequency detuning due to the Lorentz force is evaluated.

  18. Photoluminescence Spectroscopy of Rhodamine 800 Aqueous Solution and Dye-Doped Polymer Thin-Film: Concentration and Solvent Effects

    Science.gov (United States)

    Le, Khai Q.; Dang, Ngo Hai

    2018-05-01

    This paper investigates solvent and concentration effects on photoluminescence (PL) or fluorescence properties of Rhodamine 800 (Rho800) dyes formed in aqueous solution and polymer thin-film. Various commonly used organic solvents including ethanol, methanol and cyclopentanol were studied at a constant dye concentration. There were small changes in the PL spectra for the different solvents in terms of PL intensity and peak wavelength. The highest PL intensity was observed for cyclopentanol and the lowest for ethanol. The longest peak wavelength was found in cyclopentanol (716 nm) and the shortest in methanol (708 nm). Dissolving the dye powder in the methanol solvent and varying the dye concentration in aqueous solution from the high concentrated solution to highly dilute states, the wavelength tunability was observed between about 700 nm in the dilute state and 730 nm at high concentration. Such a large shift may be attributed to the formation of dye aggregates. Rho800 dye-doped polyvinyl alcohol (PVA) polymer thin-film was further investigated. The PL intensity of the dye in the form of thin-film is lower than that of the aqueous solution form whereas the peak wavelength is redshifted due to the presence of PVA. This paper, to our best knowledge, reports the first study of spectroscopic properties of Rho800 dyes in various forms and provides useful guidelines for production of controllable organic luminescence sources.

  19. Sacarose e pH na germinação in vitro de grãos de pólen de citros Sucrose and pH on in vitro pollen germination of citros

    Directory of Open Access Journals (Sweden)

    Leila Aparecida Salles

    2006-02-01

    Full Text Available Objetivou-se avaliar o efeito da sacarose e pH na germinação in vitro de grãos de pólen das cultivares Valência, Natal e Pêra. Para testar o efeito da sacarose, os grãos de pólen foram distribuídos uniformemente em placas de Petri contendo meio de cultura básico constituído de 10 gL-1 de ágar, 800 mgL-1 de nitrato de cálcio e 200 mgL-1 de ácido bórico, acrescido de sacarose (0, 50, 100, 150 e 200 gL-1. Para verificação do pH satisfatório, os grãos de pólen foram inoculados em meio de cultura contendo 10 gL-1 de ágar e 800 mgL-1 de nitrato de cálcio, 200 mgL-1 de ácido bórico,100 gL-1 de sacarose e pH de 3,5; 4,0; 4,5; 5,0; 5,5; 6,0; 6,5. Após inoculação, os grãos de pólen foram incubados em BOD a 25ºC por 12 horas. A porcentagem de germinação foi obtida com auxílio de microscópio óptico com objetiva de 10 X. Para todas as cultivares estudadas, a maior porcentagem de germinação foi obtida com 100 gL-1 de sacarose e o maior número de grãos de pólen germinados foi verificado em pH 6,5, sendo observado que maiores valores de pH aumentaram também a quantidade de polens estourados para as cultivares Natal e Pêra e diminuíram para Valência.This work was carried out in order to evaluate the effect of sucrose and pH on in vitro pollen germination of cultivars Valencia, Natal and Pera (Citrus sinensis Osbeck. Pollens were distributed in Petri dishes containing culture medium with 10 gL-1 of agar 800 mgL-1 calcium nitrate, 200 mgL-1 boric acid, added of sucrose (0, 50, 100, 150 and 200 gL-1 In order to verify the satisfactory pH, the pollen were inoculated in culture middle containing 10 agar gL-1 and 800 mgL-1 calcium nitrate, 200 mgL-1 acid bórico,100 sucrose gL-1 and pH values of 3,5; 4,0; 4,5; 5,0; 5,5; 6,0; 6,5. After inoculation, pollen were incubated at 25ºC for 12 hours B.O.D. The largest germination percentage was obtained with an aid of optical microscope with lens of 10 X. For all the studied

  20. 7 CFR 800.97 - Weighing grain in containers, land carriers, barges, and shiplots.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Weighing grain in containers, land carriers, barges... (Continued) GRAIN INSPECTION, PACKERS AND STOCKYARD ADMINISTRATION (FEDERAL GRAIN INSPECTION SERVICE), DEPARTMENT OF AGRICULTURE GENERAL REGULATIONS Weighing Provisions and Procedures § 800.97 Weighing grain in...

  1. Interaction of relativistic H- ions with thin foils

    International Nuclear Information System (INIS)

    Mohagheghi, A.H.

    1990-09-01

    The response of relativistic H - ions to thin carbon foils was investigated for beam energies ranging from 226 MeV to 800 MeV. For the foil thicknesses we have studied, ranging from 15 to 300 μg/cm 2 , an appreciable fraction of the H - beam survives intact, some H - ions are stripped down to protons, and the remainder is distributed over the states of H 0 . This experiment is different from the low energy studies in that the projectile velocity is comparable to the speed of light, leading to an interaction time of typically less than a femtosecond. The present results challenge the theoretical understanding of the interaction mechanisms. An electron spectrometer was used to selectively field-ionize the Rydberg states, 9 < n < 17, at beam energies of 581 MeV and 800 MeV. The yield of low-lying states were measured by Doppler tuning a Nd:YAG laser to excite transitions to a Rydberg state which was then field-ionized and detected. A simple model is developed to fit the yield of each state as a function of foil thickness. The simple model is successful in predicting the general features of the yield data. However, the data are suggestive of a more complex structure in the yield curves. The yield of a given state depends strongly on the foil thickness, demonstrating that the excited states are formed during the passage of the ions through a foil. The optimum thickness to produce a given state increases with the principal quantum number of the state suggesting an excitation process which is at least pratially stepwise. The results of a Monte Carlo simulation are compared with the experimental data to estimate the distribution of the excited states coming out of a foil. The distributions of the excited states and their dependence on foil thickness are discussed

  2. Parity Nonconservation in Proton-water Scattering at 800 MeV

    Science.gov (United States)

    Nagle, D. E.; Bowman, J. D.; Carlini, R.; Mischke, R. E.; Frauenfelder, H.; Harper, R. W.; Yuan, V.; McDonald, A. B.; Talaga, R.

    1982-01-01

    A search has been made for parity nonconservation in the scattering of 800 MeV polarized protons from an unpolarized water target. The result is for the longitudinal asymmetry, A{sub L} = +(6.6 +- 3.2) x 10{sup -7}. Control runs with Pb, using a thickness which gave equivalent beam broadening from Coulomb multiple scattering, but a factor of ten less nuclear interactions than the water target, gave A{sub L} = -(0.5 +- 6.0) x 10{sup -7}.

  3. Why did the FDA approve efavirenz 800 mg when co-administered with rifampin?

    Science.gov (United States)

    Liu, Jiang; Chan-Tack, Kirk M; Jadhav, Pravin; Seo, Shirley; Robertson, Sarah M; Kraft, Jeffrey; Singer, Mary E; Struble, Kimberly A; Arya, Vikram

    2014-06-01

    Literature reports regarding the efficacy of efavirenz (EFV) 600 mg with rifampin (RIF) are not consistent. Evaluation of a drug-drug interaction (DDI) study and supportive semi-mechanistic population pharmacokinetic (PK) analyses were undertaken to help delineate this issue. DDI study and supportive semi-mechanistic population PK analyses were provided by BMS. Population PK analysis was based on six studies with intensive EFV PK sampling. An ACTG study with sparse PK sampling was used for model evaluation. Simulations compared EFV exposure at various doses in combination with RIF to EFV exposures at 600 mg once daily (QD). Effects of CYP2B6 genotypes on the magnitude of EFV-RIF interaction were also explored. In DDI study, co-administering EFV 600 mg QD and RIF reduced mean EFV exposure by ~ 30%. Population PK model provided acceptable predictive performance of central tendency and variability for EFV C0, Cmax, and AUC. Simulations predicted that increasing EFV to 800 mg QD with RIF would result in EFV AUC and Cmax similar to EFV 600 mg QD alone. EFV AUC and Cmax were ~ 2 times higher in subjects with reduced function CYP2B6 genotypes. However, the RIF effect was consistent across all genotypes. EFV dose adjustment to 800 mg QD did not increase the risk of overexposure compared to 600 mg EFV QD within each genotype. Dose adjustment based on matching systemic exposure was recommended to mitigate the potential for sub-therapeutic EFV exposures. Our review did not reveal any safety concerns in subjects receiving EFV 800 mg QD with RIF.

  4. 49 CFR 800.27 - Delegation to investigative officers and employees of the Board.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Delegation to investigative officers and employees... (Continued) NATIONAL TRANSPORTATION SAFETY BOARD ORGANIZATION AND FUNCTIONS OF THE BOARD AND DELEGATIONS OF AUTHORITY Delegations of Authority to Staff Members § 800.27 Delegation to investigative officers and...

  5. 45 CFR 2519.800 - What are the evaluation requirements for Higher Education programs?

    Science.gov (United States)

    2010-10-01

    ... (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE HIGHER EDUCATION INNOVATIVE PROGRAMS FOR COMMUNITY SERVICE Evaluation Requirements § 2519.800 What are the evaluation requirements for Higher Education... 45 Public Welfare 4 2010-10-01 2010-10-01 false What are the evaluation requirements for Higher...

  6. Comparison of nickel, cobalt, palladium, and tungsten Schottky contacts on n-4H-silicon carbide

    Science.gov (United States)

    Gora, V. E.; Chawanda, A.; Nyamhere, C.; Auret, F. D.; Mazunga, F.; Jaure, T.; Chibaya, B.; Omotoso, E.; Danga, H. T.; Tunhuma, S. M.

    2018-04-01

    We have investigated the current-voltage (I-V) characteristics of nickel (Ni), cobalt (Co), tungsten (W) and palladium (Pd) Schottky contacts on n-type 4H-SiC in the 300-800 K temperature range. Results extracted from I-V measurements of Schottky barrier diodes showed that barrier height (ФBo) and ideality factor (n) were strongly dependent on temperature. Schottky barrier heights for contacts of all the metals showed an increase with temperature between 300 K and 800 K. This was attributed to barrier inhomogeneities at the interface between the metal and the semiconductor, which resulted in a distribution of barrier heights at the interface. Ideality factors of Ni, Co and Pd decreased from 1.6 to 1.0 and for W the ideality factor decreased from 1.1 to 1.0 when the temperature was increased from 300 K to 800 K respectively. The device parameters were compared to assess advantages and disadvantages of the metals for envisaged applications.

  7. MHD-activity in ohmic, diverted and limited H-mode plasmas in TCV

    International Nuclear Information System (INIS)

    Pochelon, A.; Anton, M.; Buehlmann, F.; Dutch, M.J.; Duval, B.P.; Hirt, A.; Hofmann, F.; Joye, B.; Lister, J.B.; Llobet, X.; Martin, Y.; Moret, J.M.; Nieswand, C.; Pietrzyk, A.Z.; Tonetti, G.; Weisen, H.

    1994-01-01

    During its first year of operation the TCV tokamak has produced a variety of plasma configurations with currents in the range 150 to 800 kA and elongations in the range of 1.0 to 2.05. Ohmic H-modes have been obtained in diverted discharges and discharges limited on the graphite tiles inner wall. After boronisation in May 1994 H-modes with line average densities up to 1.7x10 20 m -3 , corresponding to a Murakami parameter of 10, were obtained. (author) 5 figs., 2 refs

  8. Observation of Fermi and Gamow-Teller strength in the 800 MeV(p,n) reaction

    Energy Technology Data Exchange (ETDEWEB)

    King, N S.P.; Lisowski, P W; Morgan, G L; Craig, P N; Jeppesen, R G; Lind, D A; Shepard, J R; Ullmann, J L; Zafiratos, C D; Goodman, C D

    1986-08-07

    Angular distributions have been measured for the (p,n) reaction on targets of /sup 6/Li, /sup 12/C, /sup 13/C, and /sup 15/N at 800 MeV with an energy resolution of 2.7 MeV allowing observation of discrete nuclear levels. As is the case at lower energies, this reaction is very selective, emphasizing Gamow-Teller (GT) and Fermi transitions. Absolute cross sections of pure GT transitions are reproduced by impulse approximation calculations. The ratio vertical strokeJsub(sigmatau)vertical stroke/sup 2//vertical strokeJsub(tau)vertical stroke/sup 2/ was extracted from /sup 13/C and /sup 15/N measurements at 800 MeV and from a /sup 13/C measurement at 318 MeV.

  9. Assessment of the Polyacrylic Acid for an Ammonia Water Treatment and for Alloy 800NG SG Tube Material in Pressurized Water Reactors

    International Nuclear Information System (INIS)

    Lamouroux, Christine; You, Dominique; Plancque, Gabriel; Roy, Marc; Laire, Charles; Schnongs, Philippe

    2012-09-01

    To prevent the Steam Generators (SG) fouling by corrosion products or the Tube Support Plate (TSP) blockage the on-line injection of a dispersant such the Polyacrylic Acid (PAA) could be a relevant water treatment. Long-term trials performed in PWRs have shown that the PAA, injected at the SG inlet, facilitate the evacuation of the iron oxides by the SG blowdown. Given the ammonia treatment of the secondary water of the Belgian PWRs, the R and D program carried out was devoted to: - Verify the innocuousness of the PAA and its degradation products versus Alloy 800NG SCC susceptibility in case of over concentrations and sludge presence, - Assess the potential impact of the PAA and its thermal degradation products on the specific NH 3 water treatment. The main results can be summarized as following: The corrosion tests performed with PAA in case of over concentrations and sludge couldn't point out any negative effect of the dispersant on the SCC susceptibility of tubing materials such as Alloy 800NG. No significant modification of the tube oxide layer has been observed. At the SG operating temperature, the PAA is decomposed and a large spectrum from high to lower molecular weights polymers than the initial PAA arises. The fragmentation of the polymer into low molecular weight polyacrylic acids is obtained within 20 minutes and the average molecular weight is reduced by 50% from the original one. The thermal degradation products, their quantity and their kinetic of appearance, have been determined. The generated acetate concentration during the on-line dispersant application should remain low compared to the current values observed in the SG water. From the numerical simulation based on acetate concentration and on the kinetic law deduced from the experimental work, it can be concluded that in a 2-phase medium, the margin on the water pH compared to the neutral pH remains high. At 180 deg. C, no impact on the water pH is identified, taking into account realistic

  10. On the Origin of Multidecadal to Centennial Greenland Temperature Anomalies Over the Past 800 yr

    Science.gov (United States)

    Kobashi, T.; Shindell, D. T.; Kodera, K.; Box, J. E.; Nakaegawa, T.; Kawamura, K.

    2013-01-01

    The surface temperature of the Greenland ice sheet is among the most important climate variables for assessing how climate change may impact human societies due to its association with sea level rise. However, the causes of multidecadal-to-centennial temperature changes in Greenland temperatures are not well understood, largely owing to short observational records. To examine these, we calculated the Greenland temperature anomalies (GTA[G-NH]) over the past 800 yr by subtracting the standardized northern hemispheric (NH) temperature from the standardized Greenland temperature. This decomposes the Greenland temperature variation into background climate (NH); polar amplification; and regional variability (GTA[G-NH]). The central Greenland polar amplification factor as expressed by the variance ratio Greenland/NH is 2.6 over the past 161 yr, and 3.3-4.2 over the past 800 yr. The GTA[G-NH] explains 31-35%of the variation of Greenland temperature in the multidecadal-to-centennial time scale over the past 800 yr. We found that the GTA[G-NH] has been influenced by solar-induced changes in atmospheric circulation patterns such as those produced by the North Atlantic Oscillation/Arctic Oscillation (NAO/AO). Climate modeling and proxy temperature records indicate that the anomaly is also likely linked to solar-paced changes in the Atlantic meridional overturning circulation (AMOC) and associated changes in northward oceanic heat transport.

  11. On the origin of multidecadal to centennial Greenland temperature anomalies over the past 800 yr

    Directory of Open Access Journals (Sweden)

    T. Kobashi

    2013-03-01

    Full Text Available The surface temperature of the Greenland ice sheet is among the most important climate variables for assessing how climate change may impact human societies due to its association with sea level rise. However, the causes of multidecadal-to-centennial temperature changes in Greenland temperatures are not well understood, largely owing to short observational records. To examine these, we calculated the Greenland temperature anomalies (GTA[G-NH] over the past 800 yr by subtracting the standardized northern hemispheric (NH temperature from the standardized Greenland temperature. This decomposes the Greenland temperature variation into background climate (NH; polar amplification; and regional variability (GTA[G-NH]. The central Greenland polar amplification factor as expressed by the variance ratio Greenland/NH is 2.6 over the past 161 yr, and 3.3–4.2 over the past 800 yr. The GTA[G-NH] explains 31–35% of the variation of Greenland temperature in the multidecadal-to-centennial time scale over the past 800 yr. We found that the GTA[G-NH] has been influenced by solar-induced changes in atmospheric circulation patterns such as those produced by the North Atlantic Oscillation/Arctic Oscillation (NAO/AO. Climate modeling and proxy temperature records indicate that the anomaly is also likely linked to solar-paced changes in the Atlantic meridional overturning circulation (AMOC and associated changes in northward oceanic heat transport.

  12. Anti-Toxoplasma Activity of 2-(Naphthalene-2-γlthiol-1H Indole.

    Directory of Open Access Journals (Sweden)

    Qasem Asgari

    2015-06-01

    Full Text Available This study was undertaken to evaluate the viability, infectivity and immunity of Toxoplasma gondii tachyzoites exposed to 2-(naphthalene-2-ylthio-1H-indole.Tachyzoites of RH strain were incubated in various concentrations of 2-(naphthalene-2-ylthio-1H-indole (25-800 μM for 1.5 hours. Then, they were stained by PI and analyzed by Fluorescence-activated cell sorting (FACS. To evaluate the infectivity, the tachyzoites exposed to the different concentrations of the compound were inoculated to 10 BALB/c mice groups. For Control, parasites exposed to DMSO (0.2% v/v were also intraperitoneally inoculated into two groups of mice. The immunity of the exposed tachyzoites was evaluated by inoculation of the naïve parasite to the survived mice.The LD50 of 2-(naphthalene-2-ylthio-1H-indole was 57 μmol. The longevity of mice was dose dependent. Five mice out of group 400μmol and 3 out of group 800μmol showed immunization to the parasite.Our findings demonstrated the toxoplasmocidal activity of the compound. The presence of a well-organized transporter mechanism for indole compounds within the parasite in conjunction with several effective mechanisms of these compounds on Toxoplasma viability would open a window for production of new drugs and vaccines.

  13. In situ Raman study of C60 polymerization during isothermal pressurizing at 800 K

    International Nuclear Information System (INIS)

    Talyzin, A V; Dubrovinsky, L S

    2004-01-01

    The first in situ Raman study of C 60 isothermal compression at 800 K and up to 32 GPa was performed using rhombohedral and tetragonal phases as starting materials. The rhombohedral phase shows a phase transition to 3D polymer above 10 GPa, similar to that in experiments where isobaric heating was used at pressures of 9-13 GPa. It is shown that the T-P diagram of C 60 polymeric phases (temperature increase followed by pressurizing) is significantly different from the known P-T diagram (pressurizing followed by heating). Tetragonal polymer exhibited significantly stronger stability and can be followed at least up to ∼15 GPa. Heating up to 800 K of tetragonal polymer at pressures of 6-8 GPa confirms that, due to geometrical frustrations, the tetragonal phase remains stable even at pressure and temperature conditions at which rhombohedral polymer is usually formed

  14. Porosity Evolution of Activated Carbon Fiber Prepared from Liquefied Wood. Part I: Water Steam Activation at 650 to 800 °C

    Directory of Open Access Journals (Sweden)

    Zhi Jin

    2014-03-01

    Full Text Available Activated carbon fiber is known as an excellent adsorbent material due to its well-developed pore structure. In this work, the porosity evolution of activated carbon fiber prepared from phenol liquefied wood with water steam activation at 650 to 800 °C for 20 to 260 min was examined by physical adsorption of N2 at -196 °C. By the series of activation processes, the specific surface area and pore volume were increased with the increase of activation time, most significantly by activation at 750 °C for 20 to 180 min and by activation at 800 °C for 20 to 260 min. The microporosity was gently and progressively developed with increasing activation time at 650 to 700 °C, while it was sharply developed at the early stage of activations at 750 to 800 °C, and then tended to almost stabilize. The mesoporosity was well developed only by activation at 800 °C for longer than 100 min. The pore size distributions were principally ultramicropores (0.5 - 0.7 nm during activations at 650 to 700 °C. By activations at 750 to 800 °C, the supermicropores (0.7 to 2.0 nm as well as mesopores (2 to 4 nm became progressively more important as the activation time was increased.

  15. BN800: The advanced sodium cooled fast reactor plant based on close fuel cycle

    International Nuclear Information System (INIS)

    Wu Xingman

    2011-01-01

    As one of the advanced countries with actually fastest reactor technology, Russia has always taken a leading role in the forefront of the development of fast reactor technology. After successful operation of BN600 fast reactor nuclear power station with a capacity of six hundred thousand kilowatts of electric power for nearly 30 years, and after a few decades of several design optimization improved and completed on its basis, it is finally decided to build Unit 4 of Beloyarsk nuclear power station (BN800 fast reactor power station). The BN800 fast reactor nuclear power station is considered to be the project of the world's most advanced fast reactor nuclear power being put into implementation. The fast reactor technology in China has been developed for decades. With the Chinese pilot fast reactor to be put into operation soon, the Chinese model fast reactor power station has been put on the agenda. Meanwhile, the closed fuel cycle development strategy with fast reactor as key aspect has given rise to the concern of experts and decision-making level in relevant areas. Based on the experiences accumulated in many years in dealing the Sino-Russian cooperation in fast reactor technology, with reference to the latest Russian published and authoritative literatures regarding BN800 fast reactor nuclear power station, the author compiled this article into a comprehensive introduction for reference by leaders and experts dealing in the related fields of nuclear fuel cycle strategy and fast reactor technology development researches, etc. (authors)

  16. Next Generation Nuclear Plant Steam Generator and Intermediate Heat Exchanger Materials Research and Development Plan

    Energy Technology Data Exchange (ETDEWEB)

    J. K. Wright

    2010-09-01

    application in heat exchangers and core internals for the NGNP. The primary candidates are Inconel 617, Haynes 230, Incoloy 800H and Hastelloy XR. Based on the technical maturity, availability in required product forms, experience base, and high temperature mechanical properties all of the vendor pre-conceptual design studies have specified Alloy 617 as the material of choice for heat exchangers. Also a draft code case for Alloy 617 was developed previously. Although action was suspended before the code case was accepted by ASME, this draft code case provides a significant head start for achieving codification of the material. Similarly, Alloy 800H is the material of choice for control rod sleeves. In addition to the above listed considerations, Alloy 800H is already listed in the nuclear section of the ASME Code; although the maximum use temperature and time need to be increased.

  17. Next Generation Nuclear Plant Intermediate Heat Exchanger Materials Research and Development Plan (PLN-2804)

    Energy Technology Data Exchange (ETDEWEB)

    J. K. Wright

    2008-04-01

    application in heat exchangers and core internals for the NGNP. The primary candidates are Inconel 617, Haynes 230, Incoloy 800H and Hastelloy XR. Based on the technical maturity, availability in required product forms, experience base, and high temperature mechanical properties all of the vendor pre-conceptual design studies have specified Alloy 617 as the material of choice for heat exchangers. Also a draft code case for Alloy 617 was developed previously. Although action was suspended before the code case was accepted by ASME, this draft code case provides a significant head start for achieving codification of the material. Similarly, Alloy 800H is the material of choice for control rod sleeves. In addition to the above listed considerations, Alloy 800H is already listed in the nuclear section of the ASME Code; although the maximum use temperature and time need to be increased.

  18. Multipole Stack for the 800 MeV PS Booster

    CERN Multimedia

    1975-01-01

    The 800 MeV PS Booster had seen first beam in its 4 superposed rings in 1972, routine operation began in 1973. In the strive for ever higher beam intensities, the need for additional multipole lenses became evident. After detailed studies, the manufacture of 8 stacks of multipoles was launched in 1974. Each stack consists of 4 superposed multipoles and each multipole has 4 concentric shells. From the innermost to the outermost shell, Type A contains octupole, skew-octupole, sextupole, skew-sextupole. Type B contains skew-octupole, skew-sextupole, vertical dipole, horizontal dipole. Completion of installation in 1976 opened the way to higher beam intensities. M. Battiaz is seen here with a multipole stack and its many electrical connections.

  19. Photometry of Cygnus A at 800 and 1100 μm

    International Nuclear Information System (INIS)

    Eales, S.A.

    1989-01-01

    We have measured the fluxes of the hotspots and core of the archetypical radio galaxy Cygnus A at 800 and 1100 μm. The values for the hotspots lie on the extrapolation of the spectrum from cm-wavelengths, and are consistent with a model in which the relativistic electrons are continuously injected into a reservoir from which they escape to fill the lobes. For the central source, our data are also consistent with an extrapolation from longer wavelengths and therefore suggest that the far-infrared emission discovered by IRAS from the nucleus is from heated dust. (author)

  20. Search for exotic baryons in 800 GeV/c pp → pX

    Science.gov (United States)

    Christian, D. C.; Felix, J.; Gottschalk, E. E.; Gutierrez, G.; Hartouni, E. P.; Knapp, B. C.; Kreisler, M. N.; Moreno, G.; Reyes, M. A.; Sosa, M.; Wang, M. H. L. S.; Wehmann, A.

    2006-05-01

    We present preliminary results of the search for the pentaquark candidates Θ(1540) and Ξ(1862) using data from Fermilab experiment E690 in the reaction pp → pX at 800 GeV/c. We find that production of pentaquark resonances is heavily suppressed with respect to the production of normal baryon and antibaryon resonances.

  1. Search for exotic baryons in 800 GeV/c pp {yields} pX

    Energy Technology Data Exchange (ETDEWEB)

    Christian, D C [Fermi National Accelerator Laboratory, Batavia, Illinois (United States); Felix, J [University of Guanajuato, Leon, Guanajuato (Mexico); Gottschalk, E E [Fermi National Accelerator Laboratory, Batavia, Illinois (United States); Gutierrez, G [Fermi National Accelerator Laboratory, Batavia, Illinois (United States); Hartouni, E P [Lawrence Livermore National Laboratory, Livermore, California (United States); Knapp, B C [Columbia University, Nevis Laboratory, New York (United States); Kreisler, M N [University of Massachusetts, Amherst, Massachusetts (United States); Moreno, G [University of Guanajuato, Leon, Guanajuato (Mexico); Reyes, M A [University of Guanajuato, Leon, Guanajuato (Mexico); Sosa, M [University of Guanajuato, Leon, Guanajuato (Mexico); Wang, M H L S [Fermi National Accelerator Laboratory, Batavia, Illinois (United States); Wehmann, A [Fermi National Accelerator Laboratory, Batavia, Illinois (United States)

    2006-05-15

    We present preliminary results of the search for the pentaquark candidates {theta}(1540) and {xi}(1862) using data from Fermilab experiment E690 in the reaction pp {yields} p{sup X} at 800 GeV/c. We find that production of pentaquark resonances is heavily suppressed with respect to the production of normal baryon and antibaryon resonances.

  2. Etch pit and γ' precipitate evolution in controlled Waspaloy microstructures aged at 725, 800 and 875 deg. C

    International Nuclear Information System (INIS)

    Kelekanjeri, V. Siva Kumar G.; Gerhardt, Rosario A.

    2009-01-01

    In this paper, controlled microstructures of Waspaloy were produced with the objective of studying the kinetic mechanisms that drive microstructural evolution during short-term aging. Three individual sets of controlled microstructures were produced by an initial solution-treatment at 1145 deg. C followed by aging-treatments at 725, 800 and 875 deg. C for times up to 263.5 h. The resulting microstructures varied markedly from one aging set to the next. The three sets of aged specimens were systematically characterized via microscopy (SEM and AFM), DC four-point probe resistivity and X-ray diffraction techniques. The occurrence of perfect polygonal etch-pit shapes in the solution-treated microstructures, which transformed upon aging first into corner-rounded shapes, followed by irregular shapes and eventual dissolution, was evidenced here. This phenomenon of transformation of etch-pit shapes appears to occur concurrently with gamma prime nucleation and growth. The formation mechanism of the etch-pits and subsequent microstructural evolution upon aging are discussed herein

  3. Design & simulation of a 800 kV dynamitron accelerator by CST studio

    Directory of Open Access Journals (Sweden)

    A M Aghayan

    2015-09-01

    Full Text Available Nowadays, middle energy electrostatic accelerators in industries are widely used due to their high efficiency and low cost compared with other types of accelerators. In this paper, the importance and applications of electrostatic accelerators with 800 keV energy are studied. Design and simulation of capacitive coupling of a dynamitron accelerator is proposed. Furthermore, accelerating tube are designed and simulated by means of CST Suit Studio

  4. Experimental and petrological constraints on local-scale interaction of biotite-amphibole gneiss with H2O-CO2-(K, NaCl fluids at middle-crustal conditions: Example from the Limpopo Complex, South Africa

    Directory of Open Access Journals (Sweden)

    Oleg G. Safonov

    2012-11-01

    Full Text Available Reaction textures and fluid inclusions in the ∼2.0 Ga pyroxene-bearing dehydration zones within the Sand River biotite-hornblende orthogneisses (Central Zone of the Limpopo Complex suggest that the formation of these zones is a result of close interplay between dehydration process along ductile shear zones triggered by H2O-CO2-salt fluids at 750–800 °C and 5.5–6.2 kbar, partial melting, and later exsolution of residual brine and H2O-CO2 fluids during melt crystallization at 650–700 °C. These processes caused local variations of water and alkali activity in the fluids, resulting in various mineral assemblages within the dehydration zone. The petrological observations are substantiated by experiments on the interaction of the Sand River gneiss with the H2O-CO2-(K, NaCl fluids at 750 and 800 °C and 5.5 kbar. It follows that the interaction of biotite-amphibole gneiss with H2O-CO2-(K, NaCl fluids is accompanied by partial melting at 750–800 °C. Orthopyroxene-bearing assemblages are characteristic for temperature 800 °C and are stable in equilibrium with fluids with low salt concentrations, while salt-rich fluids produce clinopyroxene-bearing assemblages. These observations are in good agreement with the petrological data on the dehydration zones within the Sand River orthogneisses.

  5. Physiological responses of coccolithophores to abrupt exposure of naturally low pH deep seawater.

    Science.gov (United States)

    Iglesias-Rodriguez, Maria Debora; Jones, Bethan M; Blanco-Ameijeiras, Sonia; Greaves, Mervyn; Huete-Ortega, Maria; Lebrato, Mario

    2017-01-01

    Upwelling is the process by which deep, cold, relatively high-CO2, nutrient-rich seawater rises to the sunlit surface of the ocean. This seasonal process has fueled geoengineering initiatives to fertilize the surface ocean with deep seawater to enhance productivity and thus promote the drawdown of CO2. Coccolithophores, which inhabit many upwelling regions naturally 'fertilized' by deep seawater, have been investigated in the laboratory in the context of ocean acidification to determine the extent to which nutrients and CO2 impact their physiology, but few data exist in the field except from mesocosms. Here, we used the Porcupine Abyssal Plain (north Atlantic Ocean) Observatory to retrieve seawater from depths with elevated CO2 and nutrients, mimicking geoengineering approaches. We tested the effects of abrupt natural deep seawater fertilization on the physiology and biogeochemistry of two strains of Emiliania huxleyi of known physiology. None of the strains tested underwent cell divisions when incubated in waters obtained from seawater from ~1,000 m (pH = 7.9; CO2 ~560 p.p.m.; 14-17 μM nitrate) and ~4,800 m (pH = 7.9; CO2 ~600 p.p.m.; 21 μM nitrate). Emiliania huxleyi strain CCMP 88E showed no differences in growth rate or in cellular content or production rates of particulate organic (POC) and inorganic (PIC) carbon and cellular particulate organic nitrogen (PON) between treatments using water from 1,000 m and 4,800 m. However, despite the N:P ratio of seawater being comparable in water from ~1,000 and ~4,800 m, the PON production rates were three times lower in one incubation using water from ~1,000 m compared to values observed in water from ~4,800 m. Thus, the POC:PON ratios were threefold higher in cells that were incubated in ~1,000 m seawater. The heavily calcified strain NZEH exhibited lower growth rates and PIC production rates when incubated in water from ~4,800 m compared to ~1,000 m, while cellular PIC, POC and PON were higher in water from 4,800 m

  6. Secondary side IGA/IGSCC of SG alloys 600, 690 and 800 : R and D program in EDF Laboratories

    International Nuclear Information System (INIS)

    Vaillant, F.; DeBouvier, O.; Bouchacourt, M.; Stutzmann, A.; Lemaire, P.

    1998-01-01

    Many steam generators (SGs) equipped with 'mill-annealed' (MA) Alloy 600 tubings suffer significant secondary side corrosion. Until now, no degradation has been observed with either Alloy 600 TT or Alloy 690 for new SGs. The understanding of IGA/SCC of Alloy 600 MA in plants and the development of predictive models have become an important challenge to assess the life span and to reduce the maintenance costs of SGs. As degradation occurs in crevice environments which are varied and little known, EDF has undertaken an important program to improve the knowledge of crevice environments which lead to cracking. Corrosion tests are performed on Alloys 600 MA (also on 600 TT) in various environments in order to reproduce the deposits and the cracking observed on pulled tubes in laboratory conditions. Other corrosion tests are conducted in environments containing some pollutants identified by analyses of secondary water after hideout-return (sulfates) or oxidizing compounds : the influences of pH and potential are evaluated on Alloy 600 (MA or TT) and also on Alloys 690 and 800. A comprehensive model is proposed using IGA/SCC results of Alloy 600 in caustic environments. The thermomechanical parameters of the tubes and the field environmental conditions, introduced in the model, confirm some important features of SGs tubings. The model will be improved to include other detrimental environments. It will provide a useful tool to predict the life span (then steam generator replacements) and to optimize the maintenance policy of SGs still equipped with Alloys 600 MA and particularly with 600 TT (frequency and best locations of inspections). Margins will also be assessed for new SGs equipped with Alloy 690, and a comparison will be performed with Alloy 800. (author)

  7. High dielectric constant PrYxOy sensing films electrolyte-insulator-semiconductor pH-sensor for the detection of urea

    International Nuclear Information System (INIS)

    Wu, Min-Hsien; Lee, Cheng-Da; Pan, Tung-Ming

    2009-01-01

    In this paper, we describe the structural and sensing properties of high-k PrY x O y sensing films deposited on Si substrates through reactive co-sputtering. Secondary ion mass spectrometry and atomic force microscopy were employed to analyze the compositional and morphological features of these films after annealing at various temperatures. The electrolyte-insulator-semiconductor (EIS) device incorporating a PrY x O y sensing membrane that had been annealed at 800 o C exhibited good sensing characteristics, including a high sensitivity (59.07 mV pH -1 in solutions from pH 2 to 12), a low hysteresis voltage (2.4 mV in the pH loop 7 → 4 → 7 → 10 → 7), and a small drift rate (0.62 mV h -1 in the buffer solution at pH 7). The PrY x O y EIS device also showed a high selective response towards H + . This improvement can be attributed to the small number of crystal defects and the large surface roughness. In addition, the enzymatic EIS-based urea biosensor incorporating a high-k PrY x O y sensing film annealed at 800 o C allowed the potentiometric analysis of urea, at concentrations ranging from 1 to 16 mM, with a sensitivity of 9.59 mV mM -1 .

  8. Determination of an instability temperature for alloys in the cooling gas of a high temperature reactor

    International Nuclear Information System (INIS)

    Grimmer, H.; Grman, D.; Krompholz, K.; Zimmermann, U.; Ullrich, G.

    1985-05-01

    High temperature alloys designed to be used for components in the primary circuit of a helium cooled high temperature nuclear reactor show massive CO production above a certain temperature, called the instability temperature T/sub i/, which increases with increasing partial pressure of CO in the cooling gas. At p/sub CO/ = 15 microbar, T/sub i/ lies between 900 and 950 degrees C for the four alloys under investigation: T/sub i/ is lowest for the iron base alloy Incoloy 800 H and increases for the nickel base alloys in the order Inconel 617, HDA 230 and Nimonic 86. Measurements of T/sub i/ made at 3 different laboratories were compared and shown to agree for p/sub CO/ 25 microbar, compatible with CO production by a reaction of Cr2O3 with carbides. Some measurements of T/sub i/ on HDA 230 and Nimonic 86 were performed in the course of simulated reactor disturbances. They showed that the oxide layer looses its protective properties above T/sub i/. A highlight of the examinations was the detection of eta-carbides (M6C) with unusual properties. M6C is the only type of carbide occuring in HDA 230. An eta-carbide with a lattice constant of 1088.8 pm had developed at the surface of Nimonic 86 during pre-oxidation before the disturbance simulation. Its composition is estimated at Ni3SiMo2C. Eta-carbides containing Si and especially eta-carbides with lattice constants as low as 1088.8 pm have been described only rarely until now. (author)

  9. Corrosion Processes of the CANDU Steam Generator Materials in the Presence of Silicon Compounds

    International Nuclear Information System (INIS)

    Lucan, Dumitra; Fulger, Manuela; Velciu, Lucian; Lucan, Georgiana; Jinescu, Gheorghita

    2006-01-01

    The feedwater that enters the steam generators (SG) under normal operating conditions is extremely pure but, however, it contains low levels (generally in the μg/l concentration range) of impurities such as iron, chloride, sulphate, silicate, etc. When water is converted into steam and exits the steam generator, the non-volatile impurities are left behind. As a result of their concentration, the bulk steam generator water is considerably higher than the one in the feedwater. Nevertheless, the concentrations of corrosive impurities are in general sufficiently low so that the bulk water is not significantly aggressive towards steam generator materials. The impurities and corrosion products existing in the steam generator concentrate in the porous deposits on the steam generator tubesheet. The chemical reactions that take place between the components of concentrated solutions generate an aggressive environment. The presence of this environment and of the tubesheet crevices lead to localized corrosion and thus the same tubes cannot ensure the heat transfer between the fluids of the primary and secondary circuits. Thus, it becomes necessary the understanding of the corrosion process that develops into SG secondary side. The purpose of this paper is the assessment of corrosion behavior of the tubes materials (Incoloy-800) at the normal secondary circuit parameters (temperature = 2600 deg C, pressure = 5.1 MPa). The testing environment was demineralized water containing silicon compounds, at a pH=9.5 regulated with morpholine and cyclohexyl-amine (all volatile treatment - AVT). The paper presents the results of metallographic examinations as well as the results of electrochemical measurements. (authors)

  10. 30 CFR 227.800 - How will MMS monitor a State's performance of delegated functions?

    Science.gov (United States)

    2010-07-01

    ... visits and Office of the Inspector General, General Accounting Office, and MMS audits of your performance... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How will MMS monitor a State's performance of... THE INTERIOR MINERALS REVENUE MANAGEMENT DELEGATION TO STATES Performance Review § 227.800 How will...

  11. Production of 800 kW of electrical power using medium calorific gas from a biomass gasifier integrated in a combined cycle

    Energy Technology Data Exchange (ETDEWEB)

    Gulyurtlu, I.; Cabrita, I. [Instituto Nacional de Engenharia e Tecnologia Industrial, Lisboa (Portugal)

    1993-12-31

    An allothermal fluidized bed biomass gasifier is under construction to operate at a pressure slightly above atmospheric to produce a gaseous fuel of medium heating value. The output of the gasifier is 2.5 {times} 10{sup 6} kcal/h and will be attached to a gas turbine that is specifically modified to burn the gas produced. The amount of electricity to be generated will be 800 kW. The gasifying medium used is superheated steam at 2.5 bars and 400{degrees}C and the amount needed will be 280 kg/h. The gasifier will have a cross sectional area of 2.1 m{sup 2} with dimensions of 1 500 mm {times} 1 400 mm. There is a heat exchanger to provide the heat needed for the gasification reactions. The gasifier will operate at about 850{degrees}C and the biomass throughput will be about 950 kg/h. The amount of gas that is to be produced will be about 1 300 kg/h or 1 900 Nm{sup 3}/h. Part of the gas obtained will be burned in an external combustor to provide the heat for the gasifier. The gas turbine to be employed is a single shaft turbine designed to drive 750 kVA electrical generator. The turbine combustion chamber is somewhat modified to allow for the lower heating value of the gas. However, there is no loss of efficiency in the turbine output due to lower calorific value of the fuel. The turbine inlet temperature is 900/{degrees}C and that of the exhaust will be 500{degrees}C. The amount of gas to be used is about 745 Nm{sup 3}/h. The paper reports the experimental results obtained from a pilot-scale gasifier operating under similar conditions. The results of test runs carried out with a gas turbine are also presented.

  12. Kinetics and equilibria of cyanide binding to prostaglandin H synthase.

    Science.gov (United States)

    MacDonald, I D; Dunford, H B

    1989-09-01

    Cyanide binding to prostaglandin H (PGH) synthase results in a spectral shift in the Soret region. This shift was exploited to determine equilibrium and kinetic parameters of the cyanide binding process. At pH 8.0, ionic strength 0.22 M, 4 degrees C, the cyanide dissociation constant, determined from equilibrium experiments, is (65 +/- 10) microM. The binding rate constant is (2.8 +/- 0.2) x 10(3) M-1 s-1, and the dissociation rate constant is zero within experimental error. Through a kinetic study of the binding process as a function of pH, from pH 3.96 to 8.00, it was possible to determine the pKa of a heme-linked acid group on the enzyme of 4.15 +/- 0.10 with citrate buffer. An apparent pKa of 4.75 +/- 0.03 was determined with acetate buffer; this different value is attributed to complexation of the enzyme with one of the components of the acetate buffer.

  13. Multifractal property of Chinese stock market in the CSI 800 index based on MF-DFA approach

    Science.gov (United States)

    Zhu, Huijian; Zhang, Weiguo

    2018-01-01

    CSI 800 index consists of CSI 500 index and CSI 300 index, aiming to reflect the performance of stocks with large, mid and small size of China A share market. In this paper we analyze the multifractal structure of Chinese stock market in the CSI 800 index based on the multifractal detrended fluctuation analysis (MF-DFA) method. We find that the fluctuation of the closing logarithmic returns have multifractal properties, the shape and width of multifractal spectrum are depended on the weighing order q. More interestingly, we observe a bigger market crash in June-August 2015 than the one in 2008 based on the local Hurst exponents. The result provides important information for further study on dynamic mechanism of return fluctuation and whether it would trigger a new financial crisis.

  14. Investigation of creep rupture properties in air and He environments of alloy 617 at 800 °C

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woo-Gon, E-mail: wgkim@kaeri.re.k [Korea Atomic Energy Research Institute, 989-111 Daedeok-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of); Ekaputra, I.M.W.; Park, Jae-Young [Pukyong National University, Busan 608-739 (Korea, Republic of); Kim, Min-Hwan; Kim, Yong-Wan [Korea Atomic Energy Research Institute, 989-111 Daedeok-daero, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)

    2016-09-15

    Creep rupture properties for Alloy 617 were investigated by a series of creep tests under different applied stresses in air and He environments at 800 °C. The creep rupture time in air and He environments exhibited almost similar life in a short rupture time. However, when the creep rupture time reaches above 3000 h, the creep life in the He environment reduced compared with those of the air environment. The creep strain rate in the He environment was a little faster than that in the air environment above 3000 h. The reduction of creep life in the He environment was due to the difference of various microstructure features such as the carbide depleted zone, oxidation structures, surface cracking, voids below the surface, and voids in the matrix in air and He environments. Alloy 617 followed Norton’s power law and the Monkman–Grant relationship well. As the stress decreased, the creep ductility decreased slightly. The thickness of the outer and internal oxide layers presented the trend of a parabolic increase with an increase in creep rupture time in both the air and He environments. The thickness in the He environment was found to be thicker than in the air environment, although pure helium gas of 99.999% was used in the present investigation. The differences in the oxide-layer thickness caused detrimental effects on the creep resistance, even in a low oxygen-containing He agent.

  15. Investigation of creep rupture properties in air and He environments of alloy 617 at 800 °C

    International Nuclear Information System (INIS)

    Kim, Woo-Gon; Ekaputra, I.M.W.; Park, Jae-Young; Kim, Min-Hwan; Kim, Yong-Wan

    2016-01-01

    Creep rupture properties for Alloy 617 were investigated by a series of creep tests under different applied stresses in air and He environments at 800 °C. The creep rupture time in air and He environments exhibited almost similar life in a short rupture time. However, when the creep rupture time reaches above 3000 h, the creep life in the He environment reduced compared with those of the air environment. The creep strain rate in the He environment was a little faster than that in the air environment above 3000 h. The reduction of creep life in the He environment was due to the difference of various microstructure features such as the carbide depleted zone, oxidation structures, surface cracking, voids below the surface, and voids in the matrix in air and He environments. Alloy 617 followed Norton’s power law and the Monkman–Grant relationship well. As the stress decreased, the creep ductility decreased slightly. The thickness of the outer and internal oxide layers presented the trend of a parabolic increase with an increase in creep rupture time in both the air and He environments. The thickness in the He environment was found to be thicker than in the air environment, although pure helium gas of 99.999% was used in the present investigation. The differences in the oxide-layer thickness caused detrimental effects on the creep resistance, even in a low oxygen-containing He agent.

  16. Ground-water flow and quality in the Atlantic City 800-foot sand, New Jersey

    Science.gov (United States)

    McAuley, Steven D.; Barringer, Julia L.; Paulachok, Gary N.; Clark, Jeffrey S.; Zapecza, Otto S.

    2001-01-01

    The regional, confined Atlantic City 800-foot sand is the principal source of water supply for coastal communities of southern New Jersey. In response to extensive use of the aquifer--nearly 21 million gallons per day in 1986--water levels have declined to about 100 feet below sea level near Atlantic City and remain below sea level throughout the coastal areas of southern New Jersey, raising concerns about the potential for saltwater intrusion into well fields. Water levels in the Atlantic City 800-foot sand have declined in response to pumping from the aquifer since the 1890's. Water levels in the first wells drilled into the Atlantic City 800-foot sand were above land surface, and water flowed continuously from the wells. By 1986, water levels were below sea level throughout most of the coastal areas. Under current conditions, wells near the coast derive most of their supply from lateral flow contributed from the unconfined part of the aquifer northwest of the updip limit of the confining unit that overlies the Atlantic City 800- foot sand. Ground water also flows laterally from offshore areas and leaks vertically through the overlying and underlying confining units into the Atlantic City 800-foot sand. The decline in water levels upsets the historical equilibrium between freshwater and ancient saltwater in offshore parts of the aquifer and permits the lateral movement of saltwater toward pumping centers. The rate of movement is accelerated as the decline in water levels increases. The chloride concentration of aquifer water 5.3 miles offshore of Atlantic City was measured as 77 mg/L (milligrams per liter) in 1985 at a U.S. Geological Survey observation well. Salty water has also moved toward wells in Cape May County. The confined, regional nature of the Atlantic City 800-foot sand permits water levels in Cape May County to decline in response to pumping in Atlantic County and vice versa. Historically, chloride concentrations as great as 1 ,510 mg/L have been

  17. Static Magnetic Properties of AL800 Garnet Material

    Energy Technology Data Exchange (ETDEWEB)

    Kuharik, J. [Fermilab; Madrak, R. [Fermilab; Makarov, A. [Fermilab; Pellico, W. [Fermilab; Sun, S. [Fermilab; Tan, C. Y. [Fermilab; Terechkine, I. [Fermilab

    2017-05-17

    A second harmonic tunable RF cavity is being devel-oped for the Fermilab Booster. This device, which prom-ises reduction of the particle beam loss at the injection, transition, and extraction stages, employs perpendicularly biased garnet material for frequency tuning. The required range of the tuning is significantly wider than in previously built and tested tunable RF devices. As a result, the mag-netic field in the garnet comes fairly close to the gyromag-netic resonance line at the lower end of the frequency range. The chosen design concept of a tuner for the cavity cannot ensure uniform magnetic field in the garnet mate-rial; thus, it is important to know the static magnetic prop-erties of the material to avoid significant increase in the lo-cal RF loss power density. This report summarizes studies performed at Fermilab to understand variations in the mag-netic properties of the AL800 garnet material used to build the tuner of the cavity.

  18. Comparison of five automated hematology analyzers in a university hospital setting: Abbott Cell-Dyn Sapphire, Beckman Coulter DxH 800, Siemens Advia 2120i, Sysmex XE-5000, and Sysmex XN-2000.

    Science.gov (United States)

    Bruegel, Mathias; Nagel, Dorothea; Funk, Manuela; Fuhrmann, Petra; Zander, Johannes; Teupser, Daniel

    2015-06-01

    Various types of automated hematology analyzers are used in clinical laboratories. Here, we performed a side-by-side comparison of five current top of the range routine hematology analyzers in the setting of a university hospital central laboratory. Complete blood counts (CBC), differentials, reticulocyte and nucleated red blood cell (NRBC) counts of 349 patient samples, randomly taken out of routine diagnostics, were analyzed with Cell-Dyn Sapphire (Abbott), DxH 800 (Beckman Coulter), Advia 2120i (Siemens), XE-5000 and XN-2000 (Sysmex). Inter-instrument comparison of CBCs including reticulocyte and NRBC counts and investigation of flagging quality in relation to microscopy were performed with the complete set of samples. Inter-instrument comparison of five-part differential was performed using samples without atypical cells in blood smear (n=292). Automated five-part differentials and NRBCs were additionally compared with microscopy. The five analyzers showed a good concordance for basic blood count parameters. Correlations between instruments were less well for reticulocyte counts, NRBCs, and differentials. The poorest concordance for NRBCs with microscopy was observed for Advia 2120i (Kendall's τb=0.37). The highest flagging sensitivity for blasts was observed for XN-2000 (97% compared to 65%-76% for other analyzers), whereas overall specificity was comparable between different instruments. To the best of our knowledge, this is the most comprehensive side-by-side comparison of five current top of the range routine hematology analyzers. Variable analyzer quality and parameter specific limitations must be considered in defining laboratory algorithms in clinical practice.

  19. Periodical climate variations and their impact on Earth rotation for the last 800Kyr

    Science.gov (United States)

    Chapanov, Yavor; Gambis, Daniel

    2010-05-01

    The Earth rotation variations are highly affected by climatic variations associated with the glacial cycles in the late Pleistocene. The processes of glaciation, followed by ice melting, are connected with significant changes of the mean sea level. These processes redistribute great amount of water masses between oceans and ice sheets, which lead to changes of the axial moment of inertia and corresponding variations of the Universal Time UT1 and Length of Day LOD, according to the law of angular momentum conservation. The climatic variations for the last 800Kyr are analyzed by means of time series of temperature changes, determined by deuterium data from Antarctica ice core. Reconstructed glacial sea level variations for the last 380Kyr, determined by the sediments from the Red sea, are used, too. Common periodicities of the temperature and mean sea level variations are determined. Time series of the long-periodical UT1 and LOD oscillations for the last 380Kyr and 800Kyr are reconstructed by means of empirical hydrological model of global water redistribution between the ocean and ice sheets during the last glacial events.

  20. H-index in medicine is driven by original research.

    Science.gov (United States)

    Nowak, Jan K; Lubarski, Karol; Kowalik, Lukasz M; Walkowiak, Jaroslaw

    2018-02-28

    To investigate the contribution of selected types of articles to h-indices of medical researchers. We used the Web of Science to export the publication records of various members from 26 scientific medical societies (13 European, 13 North American) associated with 13 medical specialties. Those included were presidents (n=26), heads of randomly chosen committees (n=52), and randomly selected members of those committees (n=52). Publications contributing to h-index were categorized as research articles, reviews, guidelines, meta-analyses, or other published work. Overall, 3259 items authored by 129 scholars were analyzed. The median h-index was 19.5. The median contribution of research articles to h-index was 84.4%. Researchers in the upper h-index tercile (≥28.5) had a larger share of research articles that contributed to h-index in comparison with those in the lower h-index tercile (≤12.5) (median 87.3% [1st-3rd quartile: 80.0%-93.1%] vs 80.0% [50.0%-88.9%], P=0.015). We observed an analogous difference with regard to guidelines (1.1% [0%-3.7%] vs 0% [0%-0%], P=0.007). Original research drives h-indices in medicine. Although guidelines contribute to h-indices in medicine, their influence is low. The specific role of randomized controlled trials in building h-index in medicine remains to be assessed.

  1. 75 FR 801 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 500, 700, and 800 Series Turbofan Engines

    Science.gov (United States)

    2010-01-06

    ...The FAA proposes to supersede an existing airworthiness directive (AD) for Rolls-Royce plc RB211-Trent 800 series turbofan engines. That AD currently requires replacing the fuel-to-oil heat exchanger (FOHE). This proposed AD would require replacing the FOHE on the RB211-Trent 500 and RB211-Trent 700 series turbofan engines in addition to the RB211-Trent 800 series turbofan engines. This proposed AD results from mandatory continuing airworthiness information (MCAI) issued by an aviation authority of another country to identify and correct an unsafe condition on an aviation product, and results from the risk of engine FOHE blockage. The MCAI describes the unsafe condition as:

  2. 75 FR 80828 - Draft Compliance Policy Guide Sec. 510.800 Beverages-Serving Size Labeling; Availability

    Science.gov (United States)

    2010-12-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-D-0575] Draft Compliance Policy Guide Sec. 510.800 Beverages--Serving Size Labeling; Availability AGENCY: Food... comments on the draft CPG to the Division of Dockets Management (HFA-305), Food and Drug Administration...

  3. High Harmonic Inverse Free-Electron-Laser Interaction at 800 NM

    CERN Document Server

    Sears, Chris M S; Colby, Eric R; Cowan, Benjamin; Plettner, Tomas; Siemann, Robert; Spencer, James

    2005-01-01

    The inverse Free Electron Laser (IFEL) interaction has recently been proposed and used as a short wavelength modulator forμbunching of beams for laser acceleration experiments*,**. These experiments utilized the fundamental of the interaction between the laser field and electron bunch. In the current experiment, we explore the higher order resonances of the IFEL interaction from a 3 period, 1.8 centimeter wavelength undulator with a picosecond, 0.25 mJ/pulse laser at 800 nm. The resonances are observed by adjusting the gap of the undulator while keeping the beam energy constant. We will also discuss diagnostics for obtaining beam overlap and statistical techniques used to account for machine drifts and analyze the data.

  4. Effect of Al Hot-Dipping on High-Temperature Corrosion of Carbon Steel in N2/0.1% H2S Gas

    Directory of Open Access Journals (Sweden)

    Muhammad Ali Abro

    2016-02-01

    Full Text Available High-temperature corrosion of carbon steel in N2/0.1% H2S mixed gas at 600–800 °C for 50–100 h was studied after hot-dipping in the aluminum molten bath. Hot-dipping resulted in the formation of the Al topcoat and the Al-Fe alloy layer firmly adhered on the substrate. The Al-Fe alloy layer consisted primarily of a wide, tongue-like Al5Fe2 layer and narrow Al3Fe layer. When corroded at 800 °C for 100 h, the Al topcoat partially oxidized to the protective but non-adherent α-Al2O3 layer, and the interdiffusion converted the Al-Fe alloy layer to an (Al13Fe4, AlFe3-mixed layer. The interdiffusion also lowered the microhardness of the hot-dipped steel. The α-Al2O3 layer formed on the hot-dipped steel protected the carbon steel against corrosion. Without the Al hot-dipping, the carbon steel failed by forming a thick, fragile, and non-protective FeS scale.

  5. Effects of high voltage electrical stimulation on the rate of pH decline, meat quality and color stability in chilled beef carcasses

    OpenAIRE

    Mombeni, Ehsan Gharib; Mombeini, Manoochehr Gharib; Figueiredo, Lucas Chaves; Siqueira, Luciano Soares Jacintho; Dias, Debora Testoni

    2013-01-01

    Objective: To determine the effects of high voltage electrical stimulation (HVES, 800 Voltage) on rapid decreases in pH values and improvements in meat quality. Methods: A total of 50 beef carcasses were applied, divided into two groups, one as a control and another for HVES. Meat quality was evaluated based on M. longissimus dorsi by examining pH and temperature levels at 1, 2, 5, 10 and 24 h, while color stability was examined seven days after slaughter. Results: HVES decreased the pH...

  6. Clinical trials in near infrared fluorescence imaging with IRDye 800CW

    Science.gov (United States)

    Draney, Daniel R.

    2015-03-01

    A monofunctional, heptamethine dye, IRDye® 800CW, is being manufactured under GMP conditions for use in human clinical trials. When attached to a suitable targeting agent and paired with an appropriate camera system, the dye allows Near Infrared (NIR) fluorescence imaging of tumor tissue during surgery. The talk will describe the properties of the dye and give an overview of current and planned clinical trials in Europe and the USA. The dye is available in both the NHS ester and carboxylate forms for conjugation to targeting molecules. A GMP toxicology study of the dye was described in a previous publication.

  7. Synthesis, structural characterization, and dehydration analysis of uranyl zinc mellitate, (UO{sub 2})Zn(H{sub 2}O){sub 4}(H{sub 2}mel).2H{sub 2}O

    Energy Technology Data Exchange (ETDEWEB)

    Olchowka, Jakub; Volkringer, Christophe; Henry, Natacha; Loiseau, Thierry [Unite de Catalyse et Chimie du Solide (UCCS) - UMR CNRS 8181, Universite de Lille Nord de France, USTL-ENSCL, Villeneuve d' Ascq (France)

    2013-04-15

    A new heterometallic uranyl zinc carboxylate, (UO{sub 2})Zn(H{sub 2}O){sub 4}(H{sub 2}mel).2H{sub 2}O, has been hydrothermally prepared (150 C, 24 h) by using 1,2,3,4,5,6-benzenehexacarboxylic acid (mellitic acid) as organic linker in order to form a three-dimensional network. Four of the six carboxylate groups of the mellitate ligand interact with mononuclear uranyl or zinc cations, which are eightfold (hexagonal bipyramid, UO{sub 8}) or sixfold [octahedron, ZnO{sub 2}(H{sub 2}O){sub 4}] coordinated, respectively. The remaining free carboxylate arms of the mellitate species preferentially interact through hydrogen bonds with water molecules trapped within the framework. Thermogravimetric and X-ray thermodiffraction (up to 800 C) analyses and in situ infrared spectroscopy (up to 210 C) indicated that both free and bound water species are evacuated from the structure in one step between 80 and 170 C, followed by its transformation into an unknown, anhydrous, poorly crystalline phase [UO{sub 2}Zn(mel)] up to 320 C. After the formation of an amorphous phase, the re-crystallization of oxides α-ZnU{sub 3}O{sub 10} and ZnO was observed from 460 C. The fluorescence spectrum of the as-synthesized uranyl zinc mellitate shows the six bands that are typical for vibronic couplings of the [O=U=O]{sup 2+} moiety. (Copyright copyright 2013 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. 76 FR 24796 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2011-05-03

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation.... Request To Revise the Compliance Times Four commenters, American Airlines, Delta Airlines, Rolls-Royce plc... SNPRM were developed to minimize the risk of uncontained disc failure, based on the age of the parts in...

  9. Diffusion-controlled melting in granitic systems at 800-900degC and 100-200 MPa. Temperature and pressure dependence of the minimum diffusivity in granitic melts

    International Nuclear Information System (INIS)

    Yuguchi, Takashi; Yamaguchi, Takashi; Iwamoto, Manji-rou; Eguchi, Hibiki; Isobe, Hiroshi; Nishiyama, Tadao

    2012-01-01

    This paper presents the temperature and pressure dependence of the minimum binary diffusivity in granitic melts. The minimum diffusivities are determined by monitoring the temporal development of the diffusion-controlled melt layer(DCM) in granitic systems (albite (Ab)-quartz (Qtz)-H 2 O and orthoclase (Or)-Qtz-H 2 O) gathered during 31 melting experiments under conditions of 800-900degC and 100-200 MPa for durations of 19-72 h. The DCM is formed between single crystals (Ab or Or crystals) and powdered quartz in all runs and is characterized by a distinct concentration gradient. The maximum thickness of the DCM increases systematically with temperature, pressure, and run duration. Temporal development of the DCM obeys the parabolic growth rate law, using which the diffusivity can be estimated. Plots of concentrations along the diffusion paths in ternary diagrams (Na 2 O-Al 2 O 3 -SiO 2 diagram for the Ab-Qtz-H 2 O system and K 2 O-Al 2 O 3 -SiO 2 diagram for the Or-Qtz-H 2 O system) show linear trends rather than S-shaped trends, indicating that binary nature of diffusion occurs in these systems. Therefore, the diffusive component can be interpreted as an albite component or orthoclase and quartz components (SiO 2 ) rather than an oxide or a cation. (author)

  10. Accidental situations analysis in BN-800 reactor bounded with an untimely ascension of the control rods

    International Nuclear Information System (INIS)

    Gorbunov, V.S.; Zaets, N.P.

    1987-12-01

    In this document the conditions and the results of one or more control rods untimely ascension out of the BN-800 core are examined. The mathematical model which describes the reactor kinetic, the temperature core and the feedback is presented [fr

  11. Photon stimulated desorption investigations of positive ions of MgO, TiO2, Yb2O3, Nd2O3, H2O/Si(100), CaF2/Si and of H2O, CO and NO on Yb and Nd in the energy range 14 eV up to 800 eV

    International Nuclear Information System (INIS)

    Senf, F.

    1987-01-01

    Photon-stimulated desorption of positive ions from surfaces has been studied with synchrotron radiation in the photon energy range 14 -800 eV of the 'FLIPPER'-monochromator using a time-of-flight mass spectrometer. TiO 2 , as a prototype of a maximal valency ionic compound, shows a strong desorption of O +- in the photon energy range of the Ti 3 p → 3d- and Ti 2p → 3d-resonance as well as at the 0 1s-excitation due to intraatomic respectively intraatomic Auger decays, which is in agreement with the Knotek-Feibelman model. The desorption of F + from CaF 2 -covered silicon is found to follow the respective excitation and decay processes in Ca and F. In addition, the very large cross section for the F + desorption causes a radiation damage by photons of more than about 30 eV. The adsorbate system H 2 O/Si (100) needs a multiple electron excitation to show a significant desorption setting in only 30 eV above the 0 1s threshold. The rare earth metals Yb and Nd covered with O 2 , H 2 O, CO or NO exhibit a competitive desorption of O + partly due to intraatomic Auger decays caused by single electron excitations and partly due to multiple electron excitations. The variation of the 0 + yield with regard to the different adsorbates on Yb and Nd is unexpectedly low. A detailed investigation was concerned with thin oxidized Mg-films and differently prepared MgO-single-crystals. Here we found a very efficient desorption of O + and H + resulting from the excitation of O 1s-surface-excitons. In addition, the strong hole-hole-interaction energy of crystalline MgO appears to be responsible for a suppressed O + -signal in the energy range of the Mg 2p-excitation. (orig./BHO)

  12. Diffractively Produced Charm Final States in 800-GeV/c pp Collisions

    Science.gov (United States)

    Wang, M. H.; Berisso, M. C.; Christian, D. C.; Félix, J.; Gara, A.; Gottschalk, E.; Gutiérrez, G.; Hartouni, E. P.; Knapp, B. C.; Kreisler, M. N.; Lee, S.; Markianos, K.; Moreno, G.; Reyes, M. A.; Sosa, M.; Wehmann, A.; Wesson, D.

    2001-08-01

    We report the first observation of diffractively produced open charm in 800-GeV/c pp collisions of the type pp-->pD*X. We measure cross sections of σdiff(D*+) = (0.185+/-0.044+/-0.054) μb and σdiff(D*-) = (0.174+/-0.034+/-0.029) μb. Our measurements are based on 4.3×109 events recorded by FNAL E690 in the fixed-target run of 1991. We compare our results with previous fixed-target charm experiments.

  13. High Transverse Momentum Hadron Production in 400-GeV/c and 800-GeV/c Proton - Nucleon Collisions

    Energy Technology Data Exchange (ETDEWEB)

    Jaffe, David Edward [SUNY, Stony Brook

    1987-08-01

    Results of high transverse momentum hadron production in 400 Gev/c proton-proton and proton-deuteron and 800 Gev /c proton-proton collisions are presented in this dissertation. The transverse momentum range of the data was from 5.2 to 9.0 Gev/c for the 400 Gev/c collisions and from 3.6 to 11.0 Gev /c for the 800 Gev /c collisions; the data were centered around the proton-nucleon center-of-momentum production angle of 90°. Single pion invariant cross sections and particle ratios were measured at both energies and the unlike-sign dihadron correlation function was measured at the higher energy. The results are compared to previous experiments and the Lund model.

  14. A Living Landscape : Bronze Age settlement sites in the Dutch river area (c. 2000-800 BC)

    NARCIS (Netherlands)

    Arnoldussen, Stijn

    2008-01-01

    "A Living Landscape. Bronze Age settlements in the Dutch river area (c. 2000-800 BC)" Academisch proefschrift over de aard en dynamiek van bronstijdnederzettingen in het rivierengebied. Het bevat een introductie op de geologische processen en de paleogeografie van de Nederlandse rivierdelta als

  15. 75 FR 61114 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2010-10-04

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation.... Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, England, DE248BJ; telephone: 011-44... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  16. Two body photodisintegration of the deuteron from 100 to 800 MeV

    International Nuclear Information System (INIS)

    Crawford, R.; Annand, J.R.M.; Anthony, I.; Altieri, S.; Pavia Univ.; Audit, G.; D'Hose, N.

    1996-01-01

    The total and the differential cross sections for the D(γ,p)n reaction have been measured over the photon energy range 100-800 MeV at the 855 MeV MAMI Microtron in Mainz. The data are presented in the form of thirty-five angular distributions at c.m. proton angles between 30 deg-160 deg in 10 deg intervals and at photon energies in steps of 20 MeV. Previous experimental work is reassessed in the light of the present results and the results compared with some recent theoretical calculations. (author)

  17. Stable structures of Al510–800 clusters and lowest energy sequence of truncated octahedral Al clusters up to 10,000 atoms

    International Nuclear Information System (INIS)

    Wu, Xia; He, Chengdong

    2012-01-01

    Highlights: ► The stable structures of Al 510–800 clusters are obtained with the NP-B potential. ► Al 510–800 clusters adopt truncated octahedral (TO) growth pattern based on complete TOs at Al 405 , Al 586 , and Al 711 . ► The lowest energy sequence of complete TOs up to the size 10,000 is proposed. -- Abstract: The stable structures of Al 510–800 clusters are obtained using dynamic lattice searching with constructed cores (DLSc) method by the NP-B potential. According to the structural growth rule, octahedra and truncated octahedra (TO) configurations are adopted as the inner cores in DLSc method. The results show that in the optimized structures two complete TO structures are found at Al 586 and Al 711 . Furthermore, Al 510–800 clusters adopt TO growth pattern on complete TOs at Al 405 , Al 586 , and Al 711 , and the configurations of the surface atoms are investigated. On the other hand, Al clusters with complete TO motifs are studied up to the size 10,000 by the geometrical construction method. The structural characteristics of complete TOs are denoted by the term “family”, and the growth sequence of Al clusters is investigated. The lowest energy sequence of complete TOs is proposed.

  18. GASSAR-6 (General Atomic Standard Safety Analysis Report). Volume 1

    International Nuclear Information System (INIS)

    1975-01-01

    A standard nuclear steam system for a 3000 MW(t), 1160 MW(e) high temperature gas-cooled reactor (HTGR) nuclear power station is described. The HTGR operates on a uranium-235/thorium-232 cycle. Spherical fuel pellets are coated with multiple layers of pyrolytic carbon, bonded into rods, and encased in hexagonal graphite fuel elements. The core is nuclear-purity-grade, near isotropic graphite machined in hexagonal blocks, which serves as moderator and the heat transfer medium between the fuel and the coolant. Forced helium is the primary coolant and water is the secondary coolant. A prestressed concrete reactor vessel (PCRV) houses the reactor core, primary coolant system and portions of the secondary coolant system, steam generators and circulators. A continuous internal steel liner in the PCRV acts as the primary coolant boundary and sealing membrane. The control rods contain boron carbide in a graphite matrix sheathed in Incoloy 800 cans. Boron constitutes about 40 percent of the absorber material by volume. The control rod drives provide insertion and withdrawal rates consistent with the required reactivity changes for operational load fluctuations and reactor shutdown. Control rods have shim and trip capability. (U.S.)

  19. Alloy SCR-3 resistant to stress corrosion cracking

    International Nuclear Information System (INIS)

    Kowaka, Masamichi; Fujikawa, Hisao; Kobayashi, Taiki

    1977-01-01

    Austenitic stainless steel is used widely because the corrosion resistance, workability and weldability are excellent, but the main fault is the occurrence of stress corrosion cracking in the environment containing chlorides. Inconel 600, most resistant to stress corrosion cracking, is not necessarily safe under some severe condition. In the heat-affected zone of SUS 304 tubes for BWRs, the cases of stress corrosion cracking have occurred. The conventional testing method of stress corrosion cracking using boiling magnesium chloride solution has been problematical because it is widely different from actual environment. The effects of alloying elements on stress corrosion cracking are remarkably different according to the environment. These effects were investigated systematically in high temperature, high pressure water, and as the result, Alloy SCR-3 with excellent stress corrosion cracking resistance was found. The physical constants and the mechanical properties of the SCR-3 are shown. The states of stress corrosion cracking in high temperature, high pressure water containing chlorides and pure water, polythionic acid, sodium phosphate solution and caustic soda of the SCR-3, SUS 304, Inconel 600 and Incoloy 800 are compared and reported. (Kako, I.)

  20. Investigation of the 800 keV Peak in the Gamma Spectrum of Swedish Laplanders

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Nilsson, I; Eckerstig, K

    1962-08-15

    The gamma spectrum of the body radioactivity in reindeer raising Laplanders has shown a peak at 800 keV, which has not been discussed before in connection with whole body counting. We present here an investigation that was made to be able to identify the isotope. The result is that the peak comes from cesium 134. The possibility to find cesium 134 in fallout is discussed.

  1. Investigation of the 800 keV Peak in the Gamma Spectrum of Swedish Laplanders

    International Nuclear Information System (INIS)

    Andersson, I.Oe.; Nilsson, I.; Eckerstig, K.

    1962-08-01

    The gamma spectrum of the body radioactivity in reindeer raising Laplanders has shown a peak at 800 keV, which has not been discussed before in connection with whole body counting. We present here an investigation that was made to be able to identify the isotope. The result is that the peak comes from cesium 134. The possibility to find cesium 134 in fallout is discussed

  2. De taalvaardigheid van 800 instromende studenten in het Vlaamse hoger onderwijs in kaart gebracht

    OpenAIRE

    Van Houtven, Tine; Peters, Elke

    2010-01-01

    Taal en taalachterstand zijn actuele thema’s in het hoger onderwijs en steeds vaker wordt de vraag gesteld of instromende studenten talig wel over voldoendestartcompetenties beschikken. Hoewel heel wat instellingen voor hoger onderwijs de laatste jaren instaptaaltoetseninvoeren, bestaan er weinig gemeten gegevens over de taalvaardigheid van instromende studenten. We rapporteren over een studie waarbij 800 Vlaamse eerstejaarsstudenten op hun taalvaardigheid werden getest. In deze poster lichte...

  3. 76 FR 2605 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2011-01-14

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, DERBY, DE24 8BJ, UK; telephone 44 (0... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  4. Developing an international consortium to build an 800 MW coal fired power plant in Indonesia

    International Nuclear Information System (INIS)

    Jones, R.H.; Hashima, T.

    1990-01-01

    This paper describes the cooperative construction of a fossil-fueled power plant in Indonesia. The topics discussed in the paper include energy use and the market for electric power, fuel resources, history of business activities, the role of joint resources and government business policy, and preparing for bidding an 800MW coal-fired power plant

  5. Two-body photodisintegration of [sup 3]He between 200 and 800 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Isbert, V. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); Audit, G. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); D' Hose, N. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); Kerhoas, S. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); MacCormick, M. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); Tamas, G. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); Wallace, P.A. (SPhN-DAPNIA, C.E.N. Saclay, 91191 Gif sur Yvette (France)); Altieri, S. (INFN-Sezione di Pavia, via Bassi 6, 27100 Pavia (Italy) Dipartimento di Fisica Nucleare e Teorica, Universita degli Studi di Pavia, via Bassi 6, 27100 Pavia (Italy)); Braghieri, A. (INFN-Sezione di Pavia, via Bassi 6, 27100 Pavia (Italy) Dipartimento di Fisica Nucleare e Teorica, Universita degli Studi di Pavia, via Bassi 6, 27100 Pavia (Italy)); Pedroni, P. (INFN-Sezione di Pavia, via Bassi 6, 27100 Pavia (Italy)); Pinelli, T. (INFN-Sezione di Pavia, via Bassi 6; DAPHNE Collaboration

    1994-10-10

    Differential cross sections for the [sup 3]He([gamma],pd) reaction at photon energies between 200 and 800 MeV at all proton c.m. angles between 35[sup circle] and 145[sup circle] have been measured using the tagged photon beam facility of the 855 MeV MAMI accelerator in Mainz. Reaction products were detected using the large acceptance detector DAPHNE. The results confirm the rapid decrease of forward-angle cross sections with increasing E[sub [gamma

  6. The extension of the range of application of the CTC-800 climate chamber

    OpenAIRE

    DOLGIKH ARTEM; ALEXANDROVA NATALIA; POPOVA IRINA

    2017-01-01

    The article presents a research work aimed at potential improvement of the climate chamber CTC-800 to simplify the proof test of it and automate the processes it performs. To this end, the authors justify the need to apply the meter and controller of temperature and humidity of the MPR51 type as well as consider the functional MPR51-SHCH 4, its link with computer, and the compatibility of its operation with the climate chamber.

  7. Cloning and enhancing production of a detergent- and organic-solvent-resistant nattokinase from Bacillus subtilis VTCC-DVN-12-01 by using an eight-protease-gene-deficient Bacillus subtilis WB800.

    Science.gov (United States)

    Nguyen, Thao Thi; Quyen, Thi Dinh; Le, Hoang Thanh

    2013-09-10

    Nattokinases/Subtilisins (EC 3.4.21.62) belong to the second large family of serine proteases, which gain significant attention and play important role in many biotechnology processes. Thus, a number of nattokinases/subtilisins from various Bacillus species, especially from B. subtilis strains, extensively have been investigated to understand their biochemical and physical properties as well as to improve the production for industrial application. The purpose of this study was to clone a nattokinase gene from Bacillus subtilis strain VTCC-DVN-12-01, enhance its production in B. subtilis WB800, which is deficient in eight extracellular proteases and characterize its physicochemical properties for potential application in organic synthesis and detergent production. A gene coding for the nattokinase (Nk) from B. subtilis strain VTCC-DVN-12-01 consisted of an ORF of 1146 nucleotides, encoding a pre-pro-protein enzyme (30-aa pre-signal peptide, 76-aa pro-peptide and 275-aa mature protein with a predicted molecular mass of 27.7 kDa and pI 6.6). The nattokinase showed 98-99% identity with other nattokinases/subtilisins from B. subtilis strains in GenBank. Nk was expressed in B. subtilis WB800 under the control of acoA promoter at a high level of 600 mg protein per liter culture medium which is highest yield of proteins expressed in any extracellular-protease-deficient B. subtilis system till date. Nk was purified to homogeneity with 3.25 fold purification, a specific activity of 12.7 U/mg, and a recovery of 54.17%. The purified Nk was identified by MALDI-TOF mass spectrometry through three peptides, which showed 100% identity to corresponding peptides of the B. subtilis nattokinase (CAC41625). An optimal activity for Nk was observed at 65 °C and pH 9. The nattokinase was stable at temperature up to 50 °C and in pH range of 5-11 and retained more than 85% of its initial activity after incubation for 1 h. Mg2+ activated Nk up to 162% of its activity. The addition of

  8. Inclusive proton spectra and total reaction cross sections for proton-nucleus scattering at 800 MeV

    International Nuclear Information System (INIS)

    McGill, J.A.

    1981-08-01

    Current applications of multiple scattering theory to describe the elastic scattering of medium energy protons from nuclei have been shown to be quite successful in reproducing the experimental cross sections. These calculations use the impulse approximation, wherein the scattering from individual nucleons in the nucleus is described by the scattering amplitude for a free nucleon. Such an approximation restricts the inelastic channels to those initiated by nucleon-nucleon scattering. As a first step in determining the nature of p + nucleus scattering at 800 MeV, both total reaction cross sections and (p,p') inclusive cross sections were measured and compared to the free p + p cross sections for hydrogen, deuterium, calcium 40, carbon 12, and lead 208. It is concluded that as much as 85% of all reactions in a nucleus proceed from interactions with a single nucleon in the nucleus, and that the impulse approximation is a good starting point for a microscopic description of p + nucleus interactions at 800 MeV

  9. Out-of-plane emission of nuclear matter in Au+Au collisions between 100 and 800 AMeV

    International Nuclear Information System (INIS)

    Bastid, N.; Buta, A.; Crochet, P.

    1996-01-01

    We present new experimental results concerning the azimuthal distributions of light and intermediate mass fragments at midrapidity for Au (100 - 800 AMeV) +Au collisions measured with the phase I setup of the FOPI detector at GSI in Darmstadt. The azimuthal distributions are investigated as a function of the collision centrality, the incident energy, the fragment charge and transverse momentum. The maximum of the azimuthal anisotropy is obtained for collisions associated with impact parameters around 7 fm. Intermediate mass fragments present a stronger out-of-plane emission signal that light fragments. We show in particular that the azimuthal anisotropy as a function of the scaled fragment transverse momentum follows an universal curve for incident energies ranging from 250 to 800 AMeV. A signature for a transition from in-plane to out-of-plane emission is evidenced at the lowest beam energies. (author)

  10. Out-of-plane emission of nuclear matter in Au+Au collisions between 100 and 800 AMeV

    Energy Technology Data Exchange (ETDEWEB)

    Bastid, N.; Buta, A.; Crochet, P. [and others; FOPI Collaboration

    1996-12-31

    We present new experimental results concerning the azimuthal distributions of light and intermediate mass fragments at midrapidity for Au (100 - 800 AMeV) +Au collisions measured with the phase I setup of the FOPI detector at GSI in Darmstadt. The azimuthal distributions are investigated as a function of the collision centrality, the incident energy, the fragment charge and transverse momentum. The maximum of the azimuthal anisotropy is obtained for collisions associated with impact parameters around 7 fm. Intermediate mass fragments present a stronger out-of-plane emission signal that light fragments. We show in particular that the azimuthal anisotropy as a function of the scaled fragment transverse momentum follows an universal curve for incident energies ranging from 250 to 800 AMeV. A signature for a transition from in-plane to out-of-plane emission is evidenced at the lowest beam energies. (author).

  11. Some mechanical properties of borided AISI H13 and 304 steels

    International Nuclear Information System (INIS)

    Taktak, Sukru

    2007-01-01

    In the present study, mechanical properties of borides formed on AISI H13 hot work tool and AISI 304 stainless steels have been investigated. Both steels have high chromium content and have a widespread use in the engineering application. Boriding treatment was carried out in slurry salt bath consisting of borax, boric acid, and ferrosilicon at temperature range of 800-950 deg. C for 3, 5, and 7 h. X-ray diffraction analysis of boride layers on the surface of steels revealed various peaks of FeB, Fe 2 B, CrB, and Ni 3 B. Metallographic studies showed that the boride layer has a flat and smooth morphology in the 304 steel while H13 steel was a ragged morphology. The characterization of the boride layer is also carried out by means of the micro-hardness, surface roughness, adhesion, and fracture toughness studies

  12. Zircon/fluid trace element partition coefficients measured by recrystallization of Mud Tank zircon at 1.5 GPa and 800-1000 °C

    Science.gov (United States)

    Ayers, John C.; Peters, Timothy J.

    2018-02-01

    Hydrothermal zircon grains have trace element characteristics such as low Th/U, high U, and high rare earth element (REE) concentrations that distinguish them from magmatic, metamorphic, and altered zircon grains, but it is unclear whether these characteristics result from distinctive fluid compositions or zircon/fluid fractionation effects. New experiments aimed at measuring zircon/fluid trace element partition coefficients Dz/f involved recrystallizing natural Mud Tank zircon with low trace element concentrations in the presence of H2O, 1 m NaOH, or 1 m HCl doped with ∼1000 ppm of rare earth elements (REE), Y, U and Th and ∼500 ppm of Li, B, P, Nb, Ba, Hf, and Ta. Experiments were run for 168 h at 1.5 GPa, 800-1000 °C, and fO2 = NNO in a piston cylinder apparatus using the double capsule method. LA-ICP-MS analysis shows that run product zircon crystals have much higher trace element concentrations than in Mud Tank zircon starting material. Dz/f values were estimated from run product zircon analyses and bulk composition using mass balance. Most elements behave incompatibly, with median Dz/f being highest for Hf = 8 and lowest for B = 0.02. Addition of NaOH or HCl had little influence on Dz/f values. Dz/f for LREE are anomalously high, likely due to contamination of run product zircon with quenched solutes enriched in incompatible elements, so DLREE were estimated using lattice strain theory. Brice curves for +3 ions yield zircon/fluid DLu/DLa of ∼800-5000. A Brice curve fit to +4 ions yielded DCe4+ values. Estimated concentrations of Ce3+ and Ce4+ show that the average Ce4+/Ce3+ in zircon of 27 is much higher than in fluid of 0.02. Th and U show little fractionation, with median DTh/DU = 0.7, indicating that the low Th/U in natural hydrothermal zircon is inherited from the fluid. Natural fluid compositions estimated from measured Dz/f and published compositions of hydrothermal zircon grains from aplite and eclogite reflect the mineralogy of the host rock, e

  13. Modeling parameters that characterize pacing of elite female 800-m freestyle swimmers.

    Science.gov (United States)

    Lipińska, Patrycja; Allen, Sian V; Hopkins, Will G

    2016-01-01

    Pacing offers a potential avenue for enhancement of endurance performance. We report here a novel method for characterizing pacing in 800-m freestyle swimming. Websites provided 50-m lap and race times for 192 swims of 20 elite female swimmers between 2000 and 2013. Pacing for each swim was characterized with five parameters derived from a linear model: linear and quadratic coefficients for effect of lap number, reductions from predicted time for first and last laps, and lap-time variability (standard error of the estimate). Race-to-race consistency of the parameters was expressed as intraclass correlation coefficients (ICCs). The average swim was a shallow negative quadratic with slowest time in the eleventh lap. First and last laps were faster by 6.4% and 3.6%, and lap-time variability was ±0.64%. Consistency between swimmers ranged from low-moderate for the linear and quadratic parameters (ICC = 0.29 and 0.36) to high for the last-lap parameter (ICC = 0.62), while consistency for race time was very high (ICC = 0.80). Only ~15% of swimmers had enough swims (~15 or more) to provide reasonable evidence of optimum parameter values in plots of race time vs. each parameter. The modest consistency of most of the pacing parameters and lack of relationships between parameters and performance suggest that swimmers usually compensated for changes in one parameter with changes in another. In conclusion, pacing in 800-m elite female swimmers can be characterized with five parameters, but identifying an optimal pacing profile is generally impractical.

  14. Kaon scattering from C and Ca at 800 MeV/c

    International Nuclear Information System (INIS)

    Marlow, D.; Barnes, P.D.; Colella, N.J.; Dytman, S.A.; Eisenstein, R.A.; Grace, R.; Takeutchi, F.; Wharton, W.R.; Bart, S.; Hancock, D.; Hackenberg, R.; Hungerford, E.; Mayes, W.; Pinsky, L.; Williams, T.; Chrien, R.; Palevsky, H.; Sutter, R.

    1982-01-01

    Results from K +- elastic and inelastic scattering from 12 C and 40 Ca are reported. The data were all taken at an incident momentum of 800 MeV/c over an angular range from 2 to 38 0 . The elastic data are compared to first-order optical model calculations in coordinate and momentum space; good qualitative agreement is obtained. The inelastic data (from 12 C only) are compared to distorted-wave Born approximation calculations, and good agreement is found if ''realistic'' inelastic transition densities are used. Although a first-order optical potential description does not describe the data fully, there are strong indications of the increased penetrability of K + over K - in this energy range

  15. Status and initial commissioning of a high gain 800 nm SASE FEL

    CERN Document Server

    Tremaine, Aaron M; Murokh, A; Musumeci, P; Pellegrini, C; Rosenzweig, J; Babzien, M; Ben-Zvi, I; Johnson, E; Malone, R; Rakowsky, G; Skaritka, J; Wang, X J; Yu, L H; Van Bibber, K A; Hill, J M; Le Sage, G P; Carr, R; Cornacchia, M; Nuhn, H D; Ruland, R; Nguyen, D C

    2000-01-01

    We describe the status and initial commissioning of the Visible to Infrared SASE Amplifier (VISA) experiment. VISA uses a strong focusing 4 m undulator, the Brookhaven National Laboratory ATF linac with an energy of 72 MeV, and a photoinjector electron source. The VISA fundamental radiation wavelength is near 800 nm and the power expected at saturation is near 60 MW. Power, angular and spectral measurements are planned for the VISA radiation and these results will be analyzed and compared with SASE FEL theory and computer simulation. In addition, the induced electron beam micro-bunching will be measured using coherent transition radiation.

  16. Status and initial commissioning of a high gain 800 nm SASE FEL

    International Nuclear Information System (INIS)

    Tremaine, A.; Frigola, P.; Murokh, A.; Musumeci, P.; Pellegrini, C.; Rosenzweig, J.; Babzien, M.; Ben-Zvi, I.; Johnson, E.; Malone, R.; Rakowsky, G.; Skaritka, J.; Wang, X.J.; Yu, L.H.; Van Bibber, K.A.; Hill, J.M.; Le Sage, G.P.; Carr, R.; Cornacchia, M.; Nuhn, H.-D.; Ruland, R.; Nguyen, D.C.

    2000-01-01

    We describe the status and initial commissioning of the Visible to Infrared SASE Amplifier (VISA) experiment. VISA uses a strong focusing 4 m undulator, the Brookhaven National Laboratory ATF linac with an energy of 72 MeV, and a photoinjector electron source. The VISA fundamental radiation wavelength is near 800 nm and the power expected at saturation is near 60 MW. Power, angular and spectral measurements are planned for the VISA radiation and these results will be analyzed and compared with SASE FEL theory and computer simulation. In addition, the induced electron beam micro-bunching will be measured using coherent transition radiation

  17. Two body photodisintegration of the deuteron from 100 to 800 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, R.; Annand, J.R.M.; Anthony, I. [Glasgow Univ. (United Kingdom). Dept. of Physics and Astronomy; Ahrens, J.; Beck, R. [Mainz Univ. (Germany). Inst. fuer Kernphysik; Braghieri, A.; Pedroni, P. [Istituto Nazionale di Fisica Nucleare, Pavia (Italy); Altieri, S. [Istituto Nazionale di Fisica Nucleare, Pavia (Italy)]|[Pavia Univ. (Italy). Ist. di Fisica Nucleare; Audit, G.; D`Hose, N. [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Astrophysique, de la Physique des Particules, de la Physique Nucleaire et de l`Instrumentation Associee] [and others

    1996-01-01

    The total and the differential cross sections for the D({gamma},p)n reaction have been measured over the photon energy range 100-800 MeV at the 855 MeV MAMI Microtron in Mainz. The data are presented in the form of thirty-five angular distributions at c.m. proton angles between 30 deg-160 deg in 10 deg intervals and at photon energies in steps of 20 MeV. Previous experimental work is reassessed in the light of the present results and the results compared with some recent theoretical calculations. (author). Submitted to Nuclear Physics, B (NL); 23 refs.

  18. 77 FR 10355 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2012-02-22

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... service of certain critical engine parts based on reduced life limits. This new AD reduces the life limits... effective March 28, 2012. ADDRESSES: For service information identified in this AD, contact Rolls-Royce plc...

  19. Cl- channels of the gastric parietal cell that are active at low pH.

    Science.gov (United States)

    Cuppoletti, J; Baker, A M; Malinowska, D H

    1993-06-01

    HCl secretion across mammalian gastric parietal cell apical membrane may involve Cl- channels. H(+)-K(+)-ATPase-containing membranes isolated from gastric mucosa of histamine-stimulated rabbits were fused to planar lipid bilayers. Channels were recorded with symmetric 800 mM CsCl solutions, pH 7.4. A linear current-voltage (I-V) relationship was obtained, and conductance was 28 +/- 1 pS at 800 mM CsCl. Conductance was 6.9 +/- 2 pS at 150 mM CsCl. Reversal potential was +22 mV with a fivefold cis-trans CsCl concentration gradient, indicating that the channel was anion selective with a discrimination ratio of 6:1 for Cl- over Cs+. Anion selectivity of the channel was I- > Cl- > or = Br- > NO3-, and gluconate was impermeant. Channels obtained at pH 7.4 persisted when pH of medium bathing the trans side of the bilayer (pHtrans) was reduced to pH 3, without a change in conductance, linearity of I-V relationship, or ion selectivity. In contrast, asymmetric reduction of pH of medium bathing the cis side of the bilayer from 7.4 to 3 always resulted in loss of channel activity. At pH 7.4, open probability (Po) of the channel was voltage dependent, i.e., predominantly open at +80 mV but mainly closed at -80 mV. In contrast, with low pHtrans, channel Po at -80 mV was increased 3.5-fold. The Cl- channel was Ca2+ indifferent. In absence of ionophores, ion selectivity for support of H(+)-K(+)-ATPase activity and H+ transport was consistent with that exhibited by the channel and could be limited by substitution with NO3-, whereas maximal H(+)-K(+)-ATPase activity was indifferent to anion present, demonstrating that anion transport can be rate limiting. Cl- channels with similar characteristics (conductance, linear I-V relationship, and ion selectivity) were also present in H(+)-K(+)-ATPase-containing vesicles isolated from resting (cimetidine-treated) gastric mucosa, exhibiting at -80 mV a pH-independent approximately 3.5-fold lower Po than stimulated vesicle channels. At -80 m

  20. Microstructural features of dissimilar welds between 316LN austenitic stainless steel and alloy 800

    International Nuclear Information System (INIS)

    Sireesha, M.; Sundaresan, S.

    2000-01-01

    For joining type 316LN austenitic stainless steel to modified 9Cr-1Mo steel for power plant application, a trimetallic configuration using an insert piece (such as alloy 800) of intermediate thermal coefficient of expansion (CTE) has been sometimes suggested for bridging the wide gap in CTE between the two steels. Two joints are thus involved and this paper is concerned with the weld between 316LN and alloy 800. These welds were produced using three types of filler materials: austenitic stainless steels corresponding to 316,16Cr-8Ni-2Mo, and the nickel-base Inconel 182 1 . The weld fusion zones and the interfaces with the base materials were characterised in detail using light and transmission electron microscopy. The 316 and Inconel 182 weld metals solidified dendritically, while the 16-8-2(16%Cr-8%Ni-2%Mo) weld metal showed a predominantly cellular substructure. The Inconel weld metal contained a large number of inclusions when deposited from flux-coated electrodes, but was relatively inclusion-free under inert gas-shielded welding. Long-term elevated-temperature aging of the weld metals resulted in embrittling sigma phase precipitation in the austenitic stainless steel weld metals, but the nickel-base welds showed no visible precipitation, demonstrating their superior metallurgical stability for high-temperature service. (orig.)

  1. Deuteron production in α-nucleus collisions from 200 to 800 MeV per nucleon

    International Nuclear Information System (INIS)

    Montarou, G.; Alard, J.P.; Augerat, J.; Fraysse, L.; Parizet, M.J.; Babinet, R.; Fodor, Z.; Girard, J.; Gosset, J.; Laspalles, C.; Lemaire, M.C.; L'Hote, D.; Lucas, B.; Poitou, J.; Schimmerling, W.; Terrien, Y.; Brochard, F.; Gorodetzky, P.; Racca, C.; Cugnon, J.; Vandermeulen, J.

    1991-01-01

    Deuteron spectra at laboratory angles from 30 degree to 90 degree were measured in α+(Pb, Cu, and C) collisions at 800, 600, and 200 MeV/nucleon, and α+(Pb and C) collisions at 400 MeV/nucleon. The coalescence relation between protons and deuterons was examined for the inclusive part of the spectra. The size of the interacting region was evaluated from the observed coalescence coefficients. The rms radius is typically 4--5 fm, depending of the target mass. The proton and deuteron energy spectra corresponding to central collisions were fitted assuming emission from a single source moving with a velocity intermediate between that of the projectile and the target. The extracted ''temperatures'' are independent of the nature of the emitted particle, indicating that the fragments have a common source. The best fits were achieved for 200- and 400-MeV/nucleon reactions. Spectra of deuteron-like pairs, including real deuterons and neutron-proton pairs that may be contained in a larger nuclear cluster, are compared to the prediction of an intranuclear cascade model incorporating a clustering algorithm based on a classical coalescence prescription. Best agreements between experimental and predicted deuteron-like spectra occur for 800- and 600-MeV/nucleon collisions

  2. Proton spectra from 800 MeV protons on selected nuclei. Progress report, January 1, 1979-December 31, 1979

    International Nuclear Information System (INIS)

    Stearns, R.L.

    1979-09-01

    The emission of protons from targets of 6 Li, Li, 12 C, 27 Al, 40 Ca, 51 V, 90 Zr, and Pb under bombardment from 800 MeV protons was studied using the high resolution proton spectrometer at the Los Alamos Meson Physics Facility. Laboratory scattering angles of 5, 7, 9, 11, 13, 15, 20, 25, and 30 0 were measured, with special emphasis on the quasi-free region. Outgoing momenta corresponding to the region of pion production were examined at 11 and 15 0 . Absolute cross sections derived by reference to known (p,p) scattering data at 800 MeV. The quasi-free scattering has been fit with a DWIA analysis by summing over the unobserved (struck) nucleon. The systematics of proton production and the applicability of the DWIA analyses are discussed. 26 references

  3. Calculated neutron spectrum from 800-MeV protons incident on a copper beam stop

    International Nuclear Information System (INIS)

    Perry, D.G.

    1975-10-01

    A Monte Carlo calculation was performed to obtain the neutron spectrum generated by 800-MeV protons incident on the LAMPF main copper beam stop. The total flux is calculated to be of the order of 10 13 n/cm 2 -sec-mA at full-beam intensity of 1 mA, with flux spectra calculated for angles of 20 0 , 30 0 , 60 0 , 90 0 , 120 0 , and 150 0 . (auth)

  4. Oxidation behavior of stainless steel 430 and 441 at 800 C in single (air/air) and dual atmosphere (air/hydrogen) exposures

    Energy Technology Data Exchange (ETDEWEB)

    Rufner, J.; Gannon, P.; White, P.; Deibert, M.; Teintze, S. [Chemical and Biological Engineering, Montana State University, 306 Cobleigh Hall, Bozeman, MT 59717-3920 (United States); Smith, R.; Chen, H. [Physics, Montana State University, 306 Cobleigh Hall, Bozeman, MT 59717-3920 (United States)

    2008-02-15

    Intermediate temperature ({proportional_to}800 {sup o}C) planar solid oxide fuel cells (SOFCs) allow the use of ferritic stainless steel (FSS) interconnects. SOFC FSS interconnects are used to stack individual cells into series, and are simultaneously exposed to air on the cathode side and fuel on the anode side, creating a 'dual atmosphere' exposure. The thermally grown oxide (TGO) layers on the air side of FSSs 430 and 441 were analyzed as a function of simulated dual atmosphere exposures (moist air/moist hydrogen) for up to 300 h. FSS 430 showed some changes in oxidation behavior, with a slight Fe concentration increase and localized Fe{sub 2}O{sub 3} nodule formation observed in the dual atmosphere TGO layer relative to its single atmosphere (air/air) counterpart. Significantly accelerated and anomalous oxidation was observed with FSS 441 subjected to dual atmosphere exposures compared with air/air exposures. The TGO layer formed on the 441 exposed to air/air was comprised of Mn-rich, Cr and Fe-containing isomorphic spinel surface crystallites, with a Cr{sub 2}O{sub 3} (eskolaite)-based bottom layer, having a total TGO layer thickness of <2{mu} m after 300 h. In contrast, the TGO layer formed on 441 during dual atmosphere exposure was much faster-growing (>6{mu} m in 20 h) and exhibited a continuous, porous Fe{sub 2}O{sub 3}-rich surface layer with a relatively thin (<2{mu} m) sublayer of similar composition to the TGO layer formed during the air/air exposure. Spontaneous TGO layer spallation was also observed for the air side of 441 exposed to dual atmosphere for >100h. The observed oxidation behavior and TGO layer evolution of 441 in both air/air and dual atmosphere are presented, with possible mechanisms and implications discussed. (author)

  5. The pH-influenced PET processes between pyronine and different heterocycles.

    Science.gov (United States)

    Yang, Ling; Niu, Jin-Yun; Sun, Ru; Xu, Yu-Jie; Ge, Jian-Feng

    2017-10-11

    The OFF-ON and ON-OFF type pH probes based on rosamine were designed by using the relative electron densities between pyronine and various linked heterocycles. Probe 1a with an indole-pyronine skeleton gave an OFF-ON pH response (pK a = 1.41) with decreasing pH, and the relative fluorescence intensity increased 15-fold, while probe 1b with an imidazole-pyronine skeleton did not give an ON-OFF response to different pH values. When pyronine was connected with a quinolinyl group, i.e., probes 1c-d, the red emission (around 575-800 nm) gave a monotonous ON-OFF pH response (pK a = 3.26 and 2.62, respectively) with decreasing pH. The relative fluorescence intensities decreased 263- and 46-fold, respectively. Changes in the electron donating abilities of the nitrogen containing heterocycles were used to explain variations in PET processes within the probes, and their pH-dependent PET mechanisms were verified using time-dependent density functional theory calculations. Confocal fluorescence imaging was also used to evaluate the potential biomedical application of probes 1a-d. Ultimately, probe 1d with an appropriate pK a value and good biocompatibility showed lysosome targeting ability.

  6. pH-responsive lyotropic liquid crystals for the preparation of pure cubic zirconia nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    He, Wei Yan; Liu, Jin Rong; He, Zhang; Cao, Zhen Zhu; Li, Cai Hong; Gao, Yan Fang [Inner Mongolia University of Technology, School of Chemical Engineering, Hohhot (China)

    2016-07-15

    We present a lyotropic liquid crystal system consisting of SDS/Triton X-100/water at 25 C. This system is respond to pH variations with a phase switch. When pH is altered from alkaline (pH 13) to acidic (pH 2) conditions, phase change occurs from a bicontinuous hexagonal phase to a partially hexagonal phase until it disappears. The hexagonal phase under alkaline conditions is stable. Thus, this system is an ideal candidate for the preparation of pure cubic ZrO{sub 2} nanoparticles. XRD results confirm that the as-synthesized powder is composed of pure cubic ZrO{sub 2}. These nanoparticles also exhibit a thermal stability of up to 800 C. The size and morphological characteristics of the nanoparticles are greatly affected by ZrOCl{sub 2} concentration. The mechanism of zirconia nanoparticle synthesis in a lyotropic hexagonal phase was proposed. (orig.)

  7. Orbital and millennial-scale features of atmospheric CH4 over the past 800,000 years

    DEFF Research Database (Denmark)

    Loulergue, Laetitia; Schilt, Adrian; Spahni, Renato

    2008-01-01

    Atmospheric methane is an important greenhouse gas and a sensitive indicator of climate change and millennial-scale temperature variability. Its concentrations over the past 650,000 years have varied between approximately 350 and approximately 800 parts per 10(9) by volume (p.p.b.v.) during glaci...

  8. Proton nucleus elastic scattering at 800 MeV: the role of intermediate isobars

    International Nuclear Information System (INIS)

    Auger, J.P.; Maillet, J.P.; Lazard, C.; Lombard, R.J.

    1984-10-01

    Proton nucleus elastic scattering at 800 MeV has been calculated in the Glauber model for 16 O, 40 Ca, 48 Ca and 208 Pb. Nuclear densities are taken from Hartree-Fock-BCS calculations. For the nucleon-nucleon amplitudes, use is made of two recent phase shift analysis. The effects of intermediate isobars are included by means of a simple model. The results show that the experimental data are qualitatively understood. The polarization turns out to be quite sensitive to the intermediate isobar effects, which consequently need to be calculated more carefully

  9. The Beckman DxI 800 prolactin assay demonstrates superior specificity for monomeric prolactin.

    LENUS (Irish Health Repository)

    Byrne, Brendan

    2010-02-01

    Commercially available prolactin immunoassays detect macroprolactin to variable degrees. Best practice requires laboratories to assess the cross-reactivity of their prolactin assay with macroprolactin, and where appropriate, introduce a screen for the presence of macroprolactin. Our policy has been to reanalyse hyperprolactinaemic samples following polyethylene glycol (PEG) precipitation and to report the resultant value as the monomeric prolactin content of the sample. The goal of this study was to determine the need to continue PEG precipitation when prolactin measurements with the Wallac AutoDELFIA were replaced by the Beckman DxI 800.

  10. 200 kW, 800 MHz transmitter system for lower hybrid heating

    International Nuclear Information System (INIS)

    Deitz, A.

    1975-01-01

    This paper describes a new rf heating system which has just been completed and is now operational on the ATC machine. The system utilizes four UHF TV klystrons to generate at least 200 kW of power at a frequency of 800 MHz. Pulse widths can be varied from 20 μsec up to 20 msec. A radar type floating deck modulator along with photo-optical transmitting and receiving devices have been incorporated into the system to provide the pulse fidelity and versatility which characterizes this equipment. Modular construction was emphasized in the design, when possible, to reduce maintenance and down time in the advent of component falilure. Hybrid combining techniques are utilized in order to provide two 100 kW feeds into the machine

  11. Reference: 800 [Arabidopsis Phenome Database[Archive

    Lifescience Database Archive (English)

    Full Text Available cloned the gene encoding this P450 by T-DNA tagging and have confirmed the identity of the cloned gene by co...mplementation of the mutant phenotype. F5H shows 34% amino acid sequence identity... with the avocado ripening-induced P450 CYP71A1 and 32% identity with the flavonoid-3',5'-hydroxylases of Pe...anoid pathway. Since the highest degree of identity between F5H and previously sequenced P450s is only 34%,

  12. Measurements of threshold behavior for one- and two-electron photodetachment from the H/sup -/ ion

    Energy Technology Data Exchange (ETDEWEB)

    Frost, C.A.

    1981-09-01

    One and two-electron photodetachment from the H/sup -/ ion by a single photon has been studied using a crossed beam apparatus. A Q-switched laser beam was directed across the 800 MeV H/sup -/ beam at LAMPF (..beta..=0.842) resulting in Doppler-shifted photon energies in the H/sup -/ barycentric frame, which were tunable from 0.4 eV to 15.5 eV by changing the intersection angle. The particles (e/sup -/, H/sup 0/, H/sup +/) resulting from photodetachment reactions were magnetically deflected into scintillation detectors allowing the total and partial cross sections for 1e/sup -/ and 2e/sup -/ processes to be separately measured. The 2e/sup -/ signal (H/sup +/) was produced by two different mechanisms, the true signal ..gamma.. + H/sup -/ ..-->.. H/sup +/ + 2e/sup -/ and the background process ..gamma.. + H/sup -/ ..-->.. H/sup 0/(n), followed by motional electric field ionization of excited H/sup 0/. Two-electron photodetachment which had been predicted theoretically was observed for the first time, and the relative cross section was measured from threshold to 15.5 eV.

  13. Dilepton and dihadron production in proton-nucleus collisions at 800 GeV

    International Nuclear Information System (INIS)

    Mishra, C.S.

    1990-05-01

    A high statistics measurement of the atomic mass dependence of Drell-Yan, J/ψ, ψ' and Υ production induced by 800 GeV protons on deuterium, carbon, calcium, iron and tungsten targets has been performed at FermiLab (E772). The data consist of about 700,000 muon pairs covering the mass region 3 GeV ≤Mμμ 2 2 < 0.1 is slightly less than unity for heavy nuclei. J/ψ and ψ' production are strongly suppressed in heavy nuclei. An upgraded version on the spectrometer designed to measure two-body decays of neutral c and b-quark hadrons (E789) will be discussed. 17 refs., 8 figs

  14. Palliative radiation therapy for AIDS-associated Kaposi's sarcoma by using a single fraction of 800 cGy

    NARCIS (Netherlands)

    de Wit, R.; Smit, W. G.; Veenhof, K. H.; Bakker, P. J.; Oldenburger, F.; González, D. G.

    1990-01-01

    A single radiation fraction of 800 cGy was used in the treatment of acquired immunodeficiency syndrome (AIDS)-associated Kaposi's sarcoma (KS). A total of 74 radiation treatments was given to a total of 31 patients. Of all 74 evaluable treatments, there were 25 objective major responses (6 complete,

  15. Lead optimization of 3-carboxyl-4(1H)-quinolones to deliver orally bioavailable antimalarials.

    Science.gov (United States)

    Zhang, Yiqun; Clark, Julie A; Connelly, Michele C; Zhu, Fangyi; Min, Jaeki; Guiguemde, W Armand; Pradhan, Anupam; Iyer, Lalitha; Furimsky, Anna; Gow, Jason; Parman, Toufan; El Mazouni, Farah; Phillips, Margaret A; Kyle, Dennis E; Mirsalis, Jon; Guy, R Kiplin

    2012-05-10

    Malaria is a protozoal parasitic disease that is widespread in tropical and subtropical regions of Africa, Asia, and the Americas and causes more than 800,000 deaths per year. The continuing emergence of multidrug-resistant Plasmodium falciparum drives the ongoing need for the development of new and effective antimalarial drugs. Our previous work has explored the preliminary structural optimization of 4(1H)-quinolone ester derivatives, a new series of antimalarials related to the endochins. Herein, we report the lead optimization of 4(1H)-quinolones with a focus on improving both antimalarial potency and bioavailability. These studies led to the development of orally efficacious antimalarials including quinolone analogue 20g, a promising candidate for further optimization.

  16. Material híbrido orgánico-inorgánico para almacenamiento y liberación de principios activos

    OpenAIRE

    Corma, Avelino; Arrica, María Antonia; Díaz Morales, Urbano

    2007-01-01

    Material híbrido orgánico-inorgánico para almacenamiento y liberación de principios activos. La presente invención se refiere a un material híbrido compuesto por partículas de naturaleza orgánica-inorgánica caracterizado porque dichas partículas tienen un diámetro comprendido entre 10 y 800 nm, y está estructurado en dos partes: - una parte interna que comprende una fase micelar en la que se encuentran inmersos uno o más principios activos, - una parte externa compu...

  17. Comparison of temperature standards. 800 deg C to 1500 deg C (radiation pyrometers). Pt. 2

    International Nuclear Information System (INIS)

    Jimenez Rebagliati, M.; Hildebrand, E.; Tischler, M.

    1990-01-01

    A comparison between implementations of the temperature scale (IPTS-68) between 800 deg C to 1500 deg C was made at the Department of Physics and Metrology at INTI, using pyrometric lamps with a tungsten filament which were calibrated at the Physikalisch-Technische Bundesanstalt (PTB). The purpose of this analysis was the detection of possible systematic errors as well as the evaluation of the uncertainty limit. (Author) [es

  18. Observation of high-lying resonances in the H- ion

    International Nuclear Information System (INIS)

    Harris, P.G.; New Mexico Univ., Albuquerque, NM

    1990-05-01

    This dissertation reports the observation of several series of resonances, for which both electrons are in excited states, in the photodetachment cross section of H - . These 1 P doubly-excited states interfere with the continuum in which they are embedded, and appear as dips in the production cross section of excited neutral hydrogen. The experiment was performed by intersecting an 800 MeV H - beam with a (266 nm) laser beam at varying angles; the relativistic Doppler shift then ''tuned'' the photon energy in the barycentric frame. The process was observed by using a magnet strong enough the strip the electrons from the excited hydrogen atoms in selected states n and detecting the resulting protons, which allowed the isolation of the individual n channels. Three resonances are clearly visible in each channel. The data support recent theoretical calculations for the positions of doubly-excited 1 P resonances, and verify a new Rydberg-like formula for the modified Coulomb potential

  19. Alloy 800 - A review of properties and metallurgy

    International Nuclear Information System (INIS)

    Stone, P.G.; Orr, J.

    1976-01-01

    It is shown that the properties and metallurgy of alloy 800 are significantly influenced by relatively small changes in composition introduced by the nuclear industry in order to obtain better stress corrosion resistance. Two particular metallurgical effects are considered: the influence of lower TiC volume fraction on grain coarsening behavior and grain size; the influence of increased amounts of titanium in solid solution on Ni 3 (AlTi) precipitation. The first effect has a direct influence on proof stress properties, and the second on stress rupture strength and ductility. However, the important effect of aluminium on this behavior is emphasized. Other aspects considered are the effect of long reheating times during operation on proof strength and impact resistance. The final part of the paper deals with two fabrication aspects. After demonstrating the detrimental effect of cold working on stress rupture ductility, the susceptibility to premature failure is examined, using notched stress rupture specimens. Although notch sensitivity was found in short term tests, additional work suggests that it may not occur after longer testing times. The effect of stress relieving on this behavior is reported. The welding aspects considered include the compositional factors influencing liquation cracking, grain growth during welding, and the proof strength and stress rupture properties of welded material

  20. Collective effects in Au(100-800 AMeV) + Au semi-central collisions; Effets collectifs dans les collisions semi-centrales Au(100-800 AMeV) + Au

    Energy Technology Data Exchange (ETDEWEB)

    Crochet, P.

    1996-04-04

    The present work has been carried out in the framework of the experimental program of the FOPI collaboration. It is devoted to a systematic study of the different forms of collective expansion of nuclear matter in semi-central Au+Au collisions at incident energies ranging from 100 AMeV to 800 AMeV. The aim is to investigate the influence of compressional effects, momentum dependence of the nuclear interaction and nucleon-nucleon cross section on the observed phenomena. Important changes in the reaction mechanisms are evidenced, in particular at low incident energies where one observes, on the one hand, a transition from an enhanced in-plane emission to a preferential out-of-plane emission pattern and, on the other hand, a strong reduction of the directed in-plane component. Experimental results are compared to the predictions of the Quantum Molecular Dynamics (QMD) model for different parametrizations of the nuclear interaction. (author).

  1. Comparison between calculation and measurement of energy deposited by 800 MeV protons

    International Nuclear Information System (INIS)

    Loewe, W.E.

    1980-01-01

    The High Energy Transport Code, HETC, was obtained from the Radiation Shielding Information Center (RSIC) at Oak Ridge National Laboratory and altered as necessary to run on a CDC 7600 using the LTSS software in use at LLNL. HETC was then used to obtain calculated estimates of energy deposited, for comparison with a series of benchmark experiments done by LLNL. These experiments used proton beams of various energies incident on well-defined composite targets in good geometry. In this report, two aspects of the comparison between calculated and experimental energy depositions from an 800 MeV proton beam are discussed. Both aspects involve the fact that workers at SAI had previously used their version of HETC to calculate this experiment and reported their comparison with the measured data. The first aspect addressed is that their calculated data and LLNL calculations do not agree, suggesting an error in the conversion process from the RSIC code. The second aspect is not independent of the first, but is of sufficient importance to merit separate emphasis. It is that the SAI calculations agree well with experiments at the detector plate located some distance from the shower plate, whereas the LLNL calculations show a clearcut discrepancy there in comparison with the experiment. A contract was let in January 1980 by LLNL with SAI in order to obtain full details on the two cited aspects of the comparison between calculated and experimental energy depositions from an 800 MeV proton beam. The ensuing discussion is based on the final report of that contracted work

  2. Multiaxial creep of tubes of Alloy 800 and Alloy 617 at high temperature

    International Nuclear Information System (INIS)

    Penkalla, H.J.; Schubert, F.; Nickel, H.

    1989-01-01

    The deformation behaviour under multiaxial loading at temperature higher than 800 deg. C is strongly controlled by creep. For dimensioning and inelastic analysis the use of v. Mises theory and Norton's creep law for stationary creep are demonstrated for different combination of internal pressure and axial or torsional stress or strains. The experimental results are in satisfactory agreement with the theoretical predicted deformation behaviour if values for the coefficient k and n in Norton's creep law are used, which are close to the real creep resistance in the component. (author). 11 refs, 12 figs, 2 tabs

  3. Measurement of parity nonconservation in the proton-proton total cross section at 800 MeV

    International Nuclear Information System (INIS)

    Bowman, J.D.

    1986-01-01

    A report is made of a measurement of parity nonconservation in the transmission of 800-MeV longitudinally polarized protons through an unpolarized, 1-m liquid-hydrogen target. The dependence of transmission on beam properties was studied to measure and to correct for systematic errors. The measured longitudinal asymmetry in the total cross section is A/sub L/ = [+2.4 +- 1.1 (statistical) +- 0.1 (systematic)] x 10 -7 . 25 refs., 2 figs

  4. Two-body photodisintegration of the deuteron from 100 to 800 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, R.; Ahrens, J.; Altieri, S.; Annand, J.R.M.; Anthony, I.; Audit, G.; Beck, R.; Braghieri, A.; D`Hose, N.; Hall, S.; Isbert, V.; Kellie, J.D.; Kerhoas, S.; MacCormick, M.; MacGeorge, J.C.; Medaglia, R.; Miller, G.J.; Murphy, L.Y.; Owens, R.O.; Pedroni, P.; Pinelli, T.; Tamas, G.; Wallace, P.A. [Glasgow Univ. (United Kingdom). Dept. of Phys. and Astron.]|[Mainz Univ. (Germany). Inst. fuer Kernphys.]|[INFN, Sezione di Pavia (Italy)]|[Pavia Univ. (Italy). Dipartimento di Fisica Nucleare e Teorica]|[CEA-DAPNIA/SPhN, 91 - Gif-sur-Yvette (France)

    1996-06-24

    The total and the differential cross sections for the D({gamma},p)n reaction have been measured over the photon energy range 100-800 MeV at the 855 MeV MAMI Microtron in Mainz. Using the large acceptance detector DAPHNE in conjunction with the Glasgow tagging spectrometer, high precision results with small systematic errors were obtained. The data are presented in the form of thirty-five angular distributions at c.m. proton angles between 30 {sup circle} -160 {sup circle} in 10 {sup circle} intervals and at photon energies in steps of 20 MeV. Previous experimental work is reassessed in the light of the present results and comparison with some recent theoretical calculations. (orig.).

  5. INFLUENCE OF FUNCTIONAL ABILITY IN RUNNING 400 AND 800 METERS

    Directory of Open Access Journals (Sweden)

    Abdulla Elezi

    2013-07-01

    Full Text Available Goal of the research was to assess on the grounds of data collected that were used to assess the functional ability of the cardio-respiratory system and the results of running to determine the relation of these sum of variables. Basic statistical indicators of the physiological variables and results of running were calculated. For determining the relation, the regression analysis was used in the manifested space. Criterion variable (running for 100 meters did not demonstrate statistically significant coefficient of multiple variation with predictor variables. The time span in running 400 meters is short in order to engage mechanisms that supply and transform the energy for oxidative processes. Criterion variable (of running 800 meters has demonstrated statistically significant coefficient of multiple correlations with predictor variable and its value was 0.377 tested through F-test. This is understandable given that the time effect of engagement of systems responsible for transfer and transformation of energy compared to time needed for running 400 meters.

  6. Improvement of the oxidation resistance of Tribaloy T-800 alloy by the additions of yttrium and aluminium

    International Nuclear Information System (INIS)

    Zhang, Y.-D.; Zhang, C.; Lan, H.; Hou, P.Y.; Yang, Z.-G.

    2011-01-01

    Research highlights: → The additions of yttrium (Y) reduced the oxidation rate of Tribaloy T-800 alloy. → Y promoted selective oxidation of Cr due to refinement of alloy phase size. → The oxidation rate was further reduced by Y plus Al with a protective Al 2 O 3 scale. → The positive effect of Y and Al being more pronounced at the higher temperature. - Abstract: The microstructures and oxidation behaviour of the modified Tribaloy T-800 alloys by additions of yttrium and yttrium plus aluminium have been studied. At the presence of yttrium alone, the oxidation rate decreased, and the selective oxidation of chromium was promoted, which was related to the refinement of alloy phase size. The addition of yttrium plus aluminium further reduced the oxidation rate. The selective oxidation of chromium and aluminium were both promoted significantly. The benefits were especially pronounced at 1000 o C, with the formation of protective alumina external layer and no internal oxides, which may be detrimental to the alloy mechanical property.

  7. Lead corrosion and transport in simulated secondary feedwater

    Energy Technology Data Exchange (ETDEWEB)

    McGarvey, G.B. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Ross, K.J.; McDougall, T.E. [Atomic Energy of Canada Limited, Pinawa, Manitoba (Canada); Turner, C.W

    1999-07-01

    The ubiquitous presence of lead at trace levels in secondary feedwater is a concern to all operators of steam generators and has prompted laboratory studies of its interaction with Inconel 600, Inconel 690, Monel 400 and Incoloy 800. Acute exposures of steam generator alloys to high levels of lead in the laboratory and in the field have accelerated the degradation of these alloys. There is some disagreement over the role of lead when the exposure is to chronic levels. It has been proposed that most of the present degradation of steam generator tubes is caused by low levels of lead although few, if any, failures have been experimentally linked to lead when it is present in sub-parts per billion in the feedwater. One reason for the difficulty in assigning the role of the lead is related to its possible immobilization on the surfaces of corrosion products or iron oxide films in the feedwater system. We have measured lead adsorption profiles on the 3 principal corrosion products in the secondary feedwater: magnetite, lepidocrocite and hematite. In all cases, essentially complete adsorption of the lead is achieved at pH values that are lower than the pH of the feedwater (9 to 10). If lead is maintained in this adsorbed state, it may be more chemically benign than lead that is free to dissolve in the feedwater and subsequently adsorb on steam generator tube surfaces. In this paper, we report on lead adsorption onto simulated corrosion products under simulated feedwater conditions and propose a physical model for the transport and fate of lead under operating conditions. The nature of lead adsorption onto the surfaces of different corrosion products will be discussed. The desorption behaviour of lead from iron oxide surfaces after different treatment conditions will be used to propose a model for the transport and probable fate of lead in the secondary feedwater system. (author)

  8. Evidence of incomplete annealing at 800 °C and the effects of 120 °C baking on the crystal orientation and the surface superconducting properties of cold-worked and chemically polished Nb

    Science.gov (United States)

    Sung, Z.-H.; Dzyuba, A.; Lee, P. J.; Larbalestier, D. C.; Cooley, L. D.

    2015-07-01

    High-purity niobium rods were cold-worked by wire-drawing, followed by various combinations of chemical polishing and high-vacuum baking at 120 °C or annealing at 800 °C in order to better understand changes to the surface superconducting properties resulting from typical superconducting radio-frequency cavity processing. AC susceptibility measurements revealed an enhanced upper transition Tc at ˜ 9.3-9.4 K in all samples that was stable through all annealing steps, a value significantly above the accepted Tc of 9.23 K for pure annealed niobium. Corresponding elevations were seen in the critical fields, the ratio of the surface critical field Hc3 to the bulk upper critical field Hc2 rising to 2.3, well above the Ginzburg-Landau value of 1.695. Orientation imaging revealed an extensive dislocation rich sub-grain structure in the as-drawn rods, a small reduction of the surface strain after baking at 120 °C, and a substantial but incomplete recrystallization near the surface after annealing at 800 °C. We interpret these changes in surface superconducting and structural properties to extensive changes in the near-surface interstitial contamination produced by baking and annealing and to synergistic interactions between H and surface O introduced during electropolishing and buffered chemical polishing.

  9. Compressive pre-strain in Nb3Sn strand by steel tube and effect on the critical current measured on standard ITER barrel

    NARCIS (Netherlands)

    Nijhuis, Arend; Wessel, Wilhelm A.J.; Knoopers, H.G.; Ilyin, Y.; ten Kate, Herman H.J.; Della Corte, A.

    2005-01-01

    The large Cable-In-Conduit Conductors (CICC) designed for the magnet coils in the International Thermonuclear Experimental Reactor (ITER), are composed of Nb/sub 3/Sn strand bundles in a Stainless Steel (SS) or Incoloy conduit. Both, the thermal contraction of the strand composite and the conduit

  10. Residual stress measurement of the jacket material for ITER coil by neutron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Yoshinori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1998-03-01

    Nickel-Iron based super alloy INCOLOY 908 is used for the jacket of a central solenoid coil (CS coil) of the International Thermonuclear Experimental Reactor (ITER). INCOLOY 908, however, has a possibility of fracture due to Stress Accelerated Grain Boundary Oxidation (SAGBO) under a tensile residual stress beyond 200MPa. Therefore it is necessary to measure the residual stress of the jacket to avoid SAGBO. We performed residual stress measurement of the jacket by neutron diffraction using the neutron diffractometer for residual stress analysis (RESA) installed at JRR-3M in JAERI. A sample depth dependence of internal strain was obtained from the (111) plane spacing. A residual stress distribution was calculated from the strain using Young`s modulus and Poisson`s ratio that were evaluated by a tensile test with neutron diffraction. The result shows that the tensile residual stress exceeds 200MPa of the SAGBO condition in some regions inside the jacket. (author)

  11. Low cost, patterning of human hNT brain cells on parylene-C with UV & IR laser machining.

    Science.gov (United States)

    Raos, Brad J; Unsworth, C P; Costa, J L; Rohde, C A; Doyle, C S; Delivopoulos, E; Murray, A F; Dickinson, M E; Simpson, M C; Graham, E S; Bunting, A S

    2013-01-01

    This paper describes the use of 800nm femtosecond infrared (IR) and 248nm nanosecond ultraviolet (UV) laser radiation in performing ablative micromachining of parylene-C on SiO2 substrates for the patterning of human hNT astrocytes. Results are presented that support the validity of using IR laser ablative micromachining for patterning human hNT astrocytes cells while UV laser radiation produces photo-oxidation of the parylene-C and destroys cell patterning. The findings demonstrate how IR laser ablative micromachining of parylene-C on SiO2 substrates can offer a low cost, accessible alternative for rapid prototyping, high yield cell patterning.

  12. Measurements of threshold behavior for one- and two-electron photodetachment from the H- ion

    International Nuclear Information System (INIS)

    Frost, C.A.

    1981-09-01

    One and two-electron photodetachment from the H - ion by a single photon has been studied using a crossed beam apparatus. A Q-switched laser beam was directed across the 800 MeV H - beam at LAMPF (β=0.842) resulting in Doppler-shifted photon energies in the H - barycentric frame, which were tunable from 0.4 eV to 15.5 eV by changing the intersection angle. The particles (e - , H 0 , H + ) resulting from photodetachment reactions were magnetically deflected into scintillation detectors allowing the total and partial cross sections for 1e - and 2e - processes to be separately measured. The 2e - signal (H + ) was produced by two different mechanisms, the true signal γ + H - → H + + 2e - and the background process γ + H - → H 0 (n), followed by motional electric field ionization of excited H 0 . Two-electron photodetachment which had been predicted theoretically was observed for the first time, and the relative cross section was measured from threshold to 15.5 eV. Tfrared absorption spectra of intrinsic a-Si:H films by the argon working gas partial pressure, hydrogen partial pressure, and substrate temperature variperiods of time at lower temperatures because aromatic hydrocarbons economic conditions. The symptomology of the various trace metals and oxides isen as potentially more efficient for both employer and employee than is the use of regulatory standards

  13. Surface passivation at low temperature of p- and n-type silicon wafers using a double layer a-Si:H/SiNx:H

    International Nuclear Information System (INIS)

    Focsa, A.; Slaoui, A.; Charifi, H.; Stoquert, J.P.; Roques, S.

    2009-01-01

    Surface passivation of bare silicon or emitter region is of great importance towards high efficiency solar cells. Nowadays, this is usually accomplished by depositing an hydrogenated amorphous silicon nitride (a-SiNx:H) layer on n + p structures that serves also as an excellent antireflection layer. On the other hand, surface passivation of p-type silicon is better assured by an hydrogenated amorphous silicon (a-Si:H) layer but suffers from optical properties. In this paper, we reported the surface passivation of p-type and n-type silicon wafers by using an a-Si:H/SiNx:H double layer formed at low temperature (50-400 deg. C) with ECR-PECVD technique. We first investigated the optical properties (refraction index, reflectance, and absorbance) and structural properties by FTIR (bonds Si-H, N-H) of the deposited films. The hydrogen content in the layers was determined by elastic recoil detection analysis (ERDA). The passivation effect was monitored by measuring the minority carrier effective lifetime vs. different parameters such as deposition temperature and amorphous silicon layer thickness. We have found that a 10-15 nm a-Si film with an 86 nm thick SiN layer provides an optimum of the minority carriers' lifetime. It increases from an initial value of about 50-70 μs for a-Si:H to about 760 and 800 μs for a-Si:H/SiNx:H on Cz-pSi and FZ-nSi, respectively, at an injection level 2 x 10 15 cm -3 . The effective surface recombination velocity, S eff , for passivated double layer on n-type FZ Si reached 11 cm/s and for FZ-pSi-14 cm/s, and for Cz-pSi-16-20 cm/s. Effect of hydrogen in the passivation process is discussed.

  14. Effect of membrane protein concentration on binding of 3H-imipramine in human platelets

    International Nuclear Information System (INIS)

    Barkai, A.I.; Kowalik, S.; Baron, M.

    1985-01-01

    Binding of 3 H-imipramine to platelet membranes has been implicated as a marker for depression. Comparing 3 H-IMI binding between depressed patients and normal subjects we observed an increase in the dissociation constant Kd with increasing membrane protein. This phenomenon was studied more rigorously in five normal subjects. Platelet membranes were prepared and adjusted to four concentrations of protein ranging from 100 to 800 micrograms/ml. The 3 H-IMI binding parameters of maximum binding sites number (Bmax) and Kd were obtained by Scatchard analysis at each membrane concentration. A positive linear relationship was found between K/sub d/ values and the concentration of membrane protein in the assay, but no change was observed in Bmax. The variability in Kd values reported in the literature may be accounted for in part by the different concentrations of membrane protein used in various studies

  15. Preparation of acridine orange-doped silica nanoparticles for pH measurement

    International Nuclear Information System (INIS)

    Liu, Jinshui; Zang, Lingjie; Wang, Yiru; Liu, Guoning

    2014-01-01

    Acridine orange was first encapsulated into silica shell via a facile reverse microemusion method to built core–shell fluorescent nanoparticles. The nanoparticles are all in spherical shape and have a narrow size distribution, and its application as a optical pH sensor has been demonstrated. This novel sensor is based on the pH-dependent fluorescence intensities of acridine orange in different pH value. The fluorescence intensity of acridine orange-doped silica nanoparticles was decreased by increasing pH value. Under optimum conditions, the changes of fluorescence intensity were proportional to the pH value in the range of 8.00–10.90. In addition, the sensor can be easily separated by centrifugation and adds no pollution to the environment compared to the free dyes. Furthermore, the effects of ionic strength and co-existing substances were proved to have little influence on the determination of pH. The sensor has been successfully applied to determine the pH of two artificial samples. Hence, the core–shell fluorescent nanoparticles show potential for practical application. -- Highlights: • Acridine orange was encapsulated into silica shell via a facile reverse microemusion method to built core–shell fluorescent nanoparticles. • The fluorescence intensity of acridine orange-doped silica nanoparticles was decreased by increasing pH value. • Its can be used as an optical pH sensor. • The sensor can be easily separated by centrifugation and adds no pollution to the environment compared to the free dyes. • The sensor has been successfully applied to determine the pH of artificial samples

  16. Problems in the design and specification of containers for vitrified high-level liquid waste

    International Nuclear Information System (INIS)

    Corbet, A.D.W.; Hall, G.G.; Spiller, G.T.

    1976-01-01

    In the United Kingdom the growing problem of ensuring the safe storage of high-level liquid waste over long time scales has led to a policy for implementing solidification. A brief description is given of the HARVEST vitrification process, which is essentially a scaled-up version of the FINGAL process with increased throughput. The functional requirements of the container are considered. It must be made of a material which can be fabricated to a high standard. Diameters up to 600 mm for right circular cylindrical containers and 1200 mm for annular containers are contemplated. Computer aids for axisymmetric and three-dimensional heat transfer and stress analysis are identified. One example is given of the thermal profile for the cylindrical container in the furnace and another example for the annular container following an accident condition. Measured values are given for high temperature oxidation, emissivity and the short-term creep strength of various alloys. Corrosion in fresh water and sea water over long time periods and leaching of partially exposed solid waste are discussed and a conceptual package for sea bed disposal is described. The relative merits of the different methods of manufacture are pointed out and the paper concludes that HK-40 or better INCOLOY alloy 800L are suitable materials of construction. (author)

  17. Fracture toughness determination in steam generator tubes

    International Nuclear Information System (INIS)

    Bergant M; Yawny, A; Perez Ipina, J

    2012-01-01

    The assessment of the structural integrity of steam generator tubes in nuclear power plants deserved increasing attention in the last years due to the negative impact related to their failures. In this context, elastic plastic fracture mechanics (EPFM) methodology appears as a potential tool for the analysis. The application of EPFM requires, necessarily, knowledge of two aspects, i.e., the driving force estimation in terms of an elastic plastic toughness parameter (e.g., J) and the experimental measurement of the fracture toughness of the material (e.g., the material J-resistance curve). The present work describes the development of a non standardized experimental technique aimed to determine J-resistance curves for steam generator tubes with circumferential through wall cracks. The tubes were made of Incoloy 800 (Ni: 30.0-35.0; Cr: 19.0-23.0; Fe: 35.5 min, % in weight). Due to its austenitic microstructure, this alloy shows very high toughness and is widely used in applications where a good corrosion resistance in aqueous environment or an excellent oxidation resistance in high temperature environment is required. Finally, a procedure for the structural integrity analysis of steam generator tubes with crack-like defects, based on a FAD diagram (Failure Assessment Diagram), is briefly described (author)

  18. The material concept in German light water reactors. Contribution to plant safety economic efficiency and failure provision; Das Werkstoffkonzept in deutschen Leichtwasserreaktoren. Beitrag zur Anlagensicherheit, Wirtschaftlichkeit und Schadensvorsorge

    Energy Technology Data Exchange (ETDEWEB)

    Ilg, Ulf [EnBW Kernkraft GmbH (Germany). Kernkraftwerk Philippsburg; Koenig, Guenter [EnBW Kernkraft GmbH (Germany). Kernkraftwerk Neckarwestheim; Erve, Manfred [AREVA NP GmbH, Erlangen (Germany)

    2008-07-01

    In the design and construction stage of nuclear power plants relevant decisions may affect the service life of a component, and thus influence safety and availability of the plant. The German ''basic safety concept'' has an important effect on the quality of the BOL (begin of life) status. Materials selection and qualification are of significant importance for the component lifetime and the profitability of the plant. Examples for the implementation of this concept are demonstrated for the steam generator tubing material Incoloy 800, the inside-plated ferritic compound tubes as control rod drive mechanism nozzle through the RPV head of BWR plants that are not susceptible for corrosion enhanced cracking that was observed for Inconel 600 tubing. A fundamental failure analysis of crack formation in Ti stabilized austenitic pipes of BWR plants found since 1993 were definitely identified as intergranular stress corrosion caused by a local sensitization of the welding process induced overheated structured in the heat affected zone. This allowed target-oriented mitigation measures. The safety culture implemented in German nuclear plants in connection with the break preclusion or integrity concept, respectively, including a continuous actualization with respect to the state-of-the art are the technical prerequisites for damage precaution and possible life time extension.

  19. Development of expanded type plugging technique for leaky tubes of steam generators of Indian PHWRs

    International Nuclear Information System (INIS)

    Das, Nirupam; Samuel, K.A.; Joemon, V.; Rupani, B.B.

    2006-01-01

    Steam generators are very important component of Nuclear Power Plant (NPP), as they are part of Primary Heat Transport (PHT) system of Pressurised Heavy Water Reactors (PHWRs). A nuclear power plant of 220 MWe capacity has four mushroom type steam generators, each consisting of 1830 U-tubes (16 mm outside diameter and 1 mm wall thickness) made of Incoloy-800 material. The tubes of 'tube and shell type steam generator' act as the pressure boundary of PHT System. Any structural failure of these tubes may lead to release of radioactivity along with plant outage and significant economic loss. Hence, it is necessary to plug the leaky tubes for continued and safe operation of a steam generator. An expanded type plugging technique has been developed at Reactor Engineering Division to plug the leaky tubes. This plugging technique is selected because of low residual stress imparted in the adjacent 'tube to tube-sheet' joints. This plug meets the various codal requirements of steam generator. A number of qualification trials have been carried out with such plugs in the mock up facility. The expanded plugs meet the design requirements for pull out strength and leak-tightness. This paper describes the design concept of the plug, developmental aspects and qualification of the plugging technique. (author)

  20. The irradiation behaviour of boron carbide/graphite between 800 and 1,1000C

    International Nuclear Information System (INIS)

    Hattenbach, K.; Hilgendorff, W.; Weiler, K.; Zimmermann, H.U.

    1975-01-01

    64 samples of boron carbide/graphite, a material used as burnable poison in high temperature reactors, were irradiated at temperatures between 800 and 1,100 0 C up to a fluence of 1-2 x 10 20 nvt. The following post-investigations were extended to dimensional measurements to determime a possible swelling or shrinking of the pellet, corrosion tests in completely desalinated water at 300 0 C, preparation of metallographic microsections to check for crack formation, determination of the helium hold back power and the thus involved gas chromatic analysis, as well as burn-up determinations by determining the boron 10/boron 11 ratio and the lithium concentration. (orig./LN) [de

  1. 75 FR 15326 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 500, 700, and 800 Series Turbofan Engines

    Science.gov (United States)

    2010-03-29

    ... ambient conditions, ice can accumulate on the walls of the fuel pipes within the aircraft fuel system... aircraft in combination with Rolls-Royce engines that feature similar fuel systems to the RB211-Trent 800... the aircraft fuel system, which can then be released downstream when fuel flow demand is increased...

  2. New 200 kW, 800 MHz transmitter system for lower hybrid heating

    International Nuclear Information System (INIS)

    Deitz, A.

    1975-07-01

    A new rf heating system which has just been completed and is being installed on the ATC machine is described. The system utilizes four uhf TV klystrons to generate at least 200 kW of power at a frequency of 800 MHz. Pulse widths can be varied from 20 μsec. up to 20 msec. A radar type floating deck modulator along with photo-optical transmitting and receiving devices have been incorporated into the system to provide the pulse fidelity and versatility which characterizes this equipment. Modular construction was emphasized in the design, when possible, to reduce maintenance and down time in the advent of component failure. Hybrid combining techniques are utilized in order to provide two 100 kW feeds into the machine. (U.S.)

  3. Contaminants in light water reactor coolants

    International Nuclear Information System (INIS)

    Michael, I.; Bechtold, G.

    1975-01-01

    At a lower oxygen content of the pressurized water a reduced metal loss by about 10% was detected. The state of oxidation for incoloy resulting from surface examination was 2,3 +- 0,3 which corresponds to Fe 3 O 4 and a smaller fraction of iron hydroxide. (orig.) [de

  4. Spectral diffusion and electron-phonon coupling of the B800 BChl a molecules in LH2 complexes from three different species of purple bacteria.

    Science.gov (United States)

    Baier, J; Gabrielsen, M; Oellerich, S; Michel, H; van Heel, M; Cogdell, R J; Köhler, J

    2009-11-04

    We have investigated the spectral diffusion and the electron-phonon coupling of B800 bacteriochlorophyll a molecules in the peripheral light-harvesting complex LH2 for three different species of purple bacteria, Rhodobacter sphaeroides, Rhodospirillum molischianum, and Rhodopseudomonas acidophila. We come to the conclusion that B800 binding pockets for Rhodobacter sphaeroides and Rhodopseudomonas acidophila are rather similar with respect to the polarity of the protein environment but that the packaging of the alphabeta-polypeptides seems to be less tight in Rb. sphaeroides with respect to the other two species.

  5. Design and Fabrication Technique of the Key Components for Very High Temperature Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ho Jin; Song, Ki Nam; Kim, Yong Wan

    2006-12-15

    The gas outlet temperature of Very High Temperature Reactor (VHTR) may be beyond the capability of conventional metallic materials. The requirement of the gas outlet temperature of 950 .deg. C will result in operating temperatures for metallic core components that will approach very high temperature on some cases. The materials that are capable of withstanding this temperature should be prepared, or nonmetallic materials will be required for limited components. The Ni-base alloys such as Alloy 617, Hastelloy X, XR, Incoloy 800H, and Haynes 230 are being investigated to apply them on components operated in high temperature. Currently available national and international codes and procedures are needed reviewed to design the components for HTGR/VHTR. Seven codes and procedures, including five ASME Codes and Code cases, one French code (RCC-MR), and on British Procedure (R5) were reviewed. The scope of the code and code cases needs to be expanded to include the materials with allowable temperatures of 950 .deg. C and higher. The selection of compact heat exchangers technology depends on the operating conditions such as pressure, flow rates, temperature, but also on other parameters such as fouling, corrosion, compactness, weight, maintenance and reliability. Welding, brazing, and diffusion bonding are considered proper joining processes for the heat exchanger operating in the high temperature and high pressure conditions without leakage. Because VHTRs require high temperature operations, various controlled materials, thick vessels, dissimilar metal joints, and precise controls of microstructure in weldment, the more advanced joining processes are needed than PWRs. The improved solid joining techniques are considered for the IHX fabrication. The weldability for Alloy 617 and Haynes 230 using GTAW and SMAW processes was investigated by CEA.

  6. Lead corrosion and transport in simulated secondary feedwater

    International Nuclear Information System (INIS)

    McGarvey, G.B.; Ross, K.J.; McDougall, T.E.; Turner, C.W.

    1998-01-01

    The ubiquitous presence of lead at trace levels in secondary feedwater is a concern to all operators of steam generators and has prompted laboratory studies of its interaction with Inconel 600, Inconel 690, Monel 400 and Incoloy 800. Acute exposures of steam generator alloys to high levels of,lead in the laboratory and in the field have accelerated the degradation of these alloys. There is some disagreement over the role of lead when the exposure is to chronic levels. It has been proposed that most of the present degradation of steam generator tubes is due to low levels of lead although few if any failures have been experimentally linked to lead when sub-parts per billion levels are present in the feedwater. One reason for the difficulty in assigning the role of the lead is related to its possible immobilization on the surfaces of corrosion products or iron oxide films in the feedwater system. We have measured lead adsorption profiles on the three principal corrosion products in the secondary feedwater; magnetite, lepidocrocite and hematite. In all cases, essentially complete adsorption of the lead is achieved at pH values less than that of the feedwater (9-10). If lead is maintained in this adsorbed state, it may be more chemically benign than lead that is free to dissolve in the feedwater and subsequently adsorb on steam generator tube surfaces. In this paper, we report on lead adsorption onto simulated corrosion products under simulated feedwater conditions and propose a physical model for the transport and fate of lead under operating conditions. The nature of lead adsorption onto the surfaces of different corrosion products will be discussed. The desorption behaviour of lead from iron oxide surfaces following different treatment conditions will be used to propose a model for tile transport and probable fate of lead in the secondary feedwater system. (author)

  7. Lead corrosion and transport in simulated secondary feedwater

    Energy Technology Data Exchange (ETDEWEB)

    McGarvey, G.B. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Ross, K.J.; McDougall, T.E. [Atomic Energy of Canada Limited, Pinawa, Manitoba (Canada); Turner, C.W. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    1998-07-01

    The ubiquitous presence of lead at trace levels in secondary feedwater is a concern to all operators of steam generators and has prompted laboratory studies of its interaction with Inconel 600, Inconel 690, Monel 400 and Incoloy 800. Acute exposures of steam generator alloys to high levels of,lead in the laboratory and in the field have accelerated the degradation of these alloys. There is some disagreement over the role of lead when the exposure is to chronic levels. It has been proposed that most of the present degradation of steam generator tubes is due to low levels of lead although few if any failures have been experimentally linked to lead when sub-parts per billion levels are present in the feedwater. One reason for the difficulty in assigning the role of the lead is related to its possible immobilization on the surfaces of corrosion products or iron oxide films in the feedwater system. We have measured lead adsorption profiles on the three principal corrosion products in the secondary feedwater; magnetite, lepidocrocite and hematite. In all cases, essentially complete adsorption of the lead is achieved at pH values less than that of the feedwater (9-10). If lead is maintained in this adsorbed state, it may be more chemically benign than lead that is free to dissolve in the feedwater and subsequently adsorb on steam generator tube surfaces. In this paper, we report on lead adsorption onto simulated corrosion products under simulated feedwater conditions and propose a physical model for the transport and fate of lead under operating conditions. The nature of lead adsorption onto the surfaces of different corrosion products will be discussed. The desorption behaviour of lead from iron oxide surfaces following different treatment conditions will be used to propose a model for tile transport and probable fate of lead in the secondary feedwater system. (author)

  8. Design and Fabrication Technique of the Key Components for Very High Temperature Reactor

    International Nuclear Information System (INIS)

    Lee, Ho Jin; Song, Ki Nam; Kim, Yong Wan

    2006-12-01

    The gas outlet temperature of Very High Temperature Reactor (VHTR) may be beyond the capability of conventional metallic materials. The requirement of the gas outlet temperature of 950 .deg. C will result in operating temperatures for metallic core components that will approach very high temperature on some cases. The materials that are capable of withstanding this temperature should be prepared, or nonmetallic materials will be required for limited components. The Ni-base alloys such as Alloy 617, Hastelloy X, XR, Incoloy 800H, and Haynes 230 are being investigated to apply them on components operated in high temperature. Currently available national and international codes and procedures are needed reviewed to design the components for HTGR/VHTR. Seven codes and procedures, including five ASME Codes and Code cases, one French code (RCC-MR), and on British Procedure (R5) were reviewed. The scope of the code and code cases needs to be expanded to include the materials with allowable temperatures of 950 .deg. C and higher. The selection of compact heat exchangers technology depends on the operating conditions such as pressure, flow rates, temperature, but also on other parameters such as fouling, corrosion, compactness, weight, maintenance and reliability. Welding, brazing, and diffusion bonding are considered proper joining processes for the heat exchanger operating in the high temperature and high pressure conditions without leakage. Because VHTRs require high temperature operations, various controlled materials, thick vessels, dissimilar metal joints, and precise controls of microstructure in weldment, the more advanced joining processes are needed than PWRs. The improved solid joining techniques are considered for the IHX fabrication. The weldability for Alloy 617 and Haynes 230 using GTAW and SMAW processes was investigated by CEA

  9. S100a8/NF-κB signal pathway is involved in the 800-nm diode laser-induced skin collagen remodeling.

    Science.gov (United States)

    Ren, Xiaolin; Ge, Minggai; Qin, Xiaofeng; Xu, Peng; Zhu, Pingya; Dang, Yongyan; Gu, Jun; Ye, Xiyun

    2016-05-01

    The 800-nm diode laser is widely used for hair removal and also promotes collagen synthesis, but the molecular mechanism by which dermis responses to the thermal damage induced by the 800-nm diode laser is still unclear. Ten 2-month-old mice were irradiated with the 800-nm diode laser at 20, 40, and 60 J/cm(2), respectively. Skin samples were taken for PCR, Western blot analysis, and histological study at day 3 or 30 after laser irradiation. The expression of S100a8 and its two receptors (advanced glycosylation end product-specific receptor, RAGE and toll-like receptor 4, TRL4) was upregulated at day 3 after laser treatments. P-p65 levels were also elevated, causing the increase of cytokine (tumor necrosis factor, TNF-α and interleukin 6, IL-6) and MMPs (MMP1a, MMP9). At day 30, PCR and Western blot analysis showed significant increase of type I and III procollagen in the dermis treated with laser. Importantly, skin structure was markedly improved in the laser-irradiated skin compared with the control. Thus, it seemed that S100a8 upregulation triggered NF-κB signal pathway through RAGE and TLR4, responding to laser-induced dermis wound healing. The involvement of the NF-κB pathway in MMP gene transcription promoted the turnover of collagen in the skin, accelerating new collagen synthesis.

  10. Comparison of the Effect of 800 mg Ibuprofen and 30 mg Predenisolone on Relief of Post Endodontic Pain

    Directory of Open Access Journals (Sweden)

    S.M. Jalalzadeh

    2009-04-01

    Full Text Available Introduction & Objective: One of the important problems in dentistry is post endodontic pains .The purpose of this study was comparison of the effect of prophylactic oral ibuprofen 800mg and oral predenisolone 30mg on prevention of post endodontic pain.Materials & Methods: The present study is a double-blind, randomized and controlled trial. It was conducted on 60 patient (16men and 44 women between the ages of 18-63 who needed endodontic treatment. Inclusive criteria for selecting of patients were: need for root canal therapy in one of the posterior teeth, having no systemic problem, no evidence of abscess; not taking analgesic or similar drug for at least 6 hours before treatment. Patients were divided into three experimental groups randomly taking one of the drugs before the treatment {ibuprofen 800 mg, prednisolone30mg and placebo (oral dextrose}. Patients completed VAS at 6,12 and 24 hours post root canal therapy and analyzed using the spss15 by chi-square, ANOVA test and Tukey test.Results: During 24 hours after treatment post endodontic pain is 95%- 100% in the placebo group. The prevalence of no-pain was not significant 6, 12 and 24 hours after treatment between the ibuprofen and predenisolone groups. The mean scale of pain in ibuprofen and predenisolone groups was significantly lower than placebo group 6, 12 and 24 hours after treatment. Differences between the drug groups are significant only on 6 and 12 hours after treatment.Conclusion: Post endodontic pains are present 24 hours after treatment. 6 and 12 hours after treatment 30 mg predenisolone are significantly better for pain relief than 800 mg ibuprofen. But after 24 hours it is not significant.

  11. 75 FR 58290 - Airworthiness Directives; Rolls-Royce plc RB211 Trent 700 and Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2010-09-24

    ... Airworthiness Directives; Rolls-Royce plc RB211 Trent 700 and Trent 800 Series Turbofan Engines AGENCY: Federal... or increase the scope of the AD. Costs of Compliance Based on the service information, we estimate.... Required parts would cost about $15,000 per product. Based on these figures, we estimate the cost of the AD...

  12. Alat Monitoring Suhu Melalui Aplikasi Android Menggunakan Sensor LM35 dan Modul SIM800L Berbasis Mikrokontroler ATMega16

    Directory of Open Access Journals (Sweden)

    I Kadek Agus Sara Sawita

    2017-10-01

    Full Text Available It has been successfully designed a temperature monitoring instrument through android application using LM35 sensor and SIM800L module based on ATMega16 microcontroller. The temperature is measured using a LM35 sensor which produces a voltage and sent to ADC. Microcontroller ATMega16 is using as the main processor of this monitoring instrument to calculate the program, so that analog data in the form of input voltage are converted into digital data form a measurable temperature. The measurable temperature is sent and saved in the database on the server computer using the SIM800L module so it can be displayed on the website. The website pages are accessed with android programs that installed on the smartphone so that measurable temperature data can be monitored using a smartphone. The measurable temperature results can be displayed on a 2x16-character LCD in the instrument designed. Compatibility of monitoring instrument with comparison instrument is 99,97 %.

  13. Structural evolution of a 2205 duplex stainless steel between 500 C and 800 C and pitting corrosion resistance

    International Nuclear Information System (INIS)

    Kordatos, J.D.; Papadimitriou, G.; Fourlaris, G.

    1999-01-01

    The cooling rate of a duplex stainless steel from high temperature (region of stability of α-ferrite) down to the ambient temperature is critical for the mutual formation of its constituent phases, i.e. ferrite and austenite, and for their content in alloying elements. Therefore it is expected that cooling rates will affect indirectly the transformation and precipitation phenomena occuring during subsequent heat treatment. The aim of this study is to investigate the influence of the cooling rate on the transformation behavior of a SAF 2205 duplex stainless steel subjected to heat treatments in the temperature range between 500 C to 800 C. The specimens were solution annealed at 1100 C and then cooled in air, oil or water. They were subsequently subjected to isothermal heat treatment for 5 hours at temperatures of 500, 600, 700 and 800 C. The structural evolution was investigated using several techniques, among them optical, scanning and transmission electron microscopy coupled with extensive EDS X-ray microanalysis and selected area electron diffraction pattern analysis. (orig.)

  14. A data management program for the Electra 800 automatic analyser.

    Science.gov (United States)

    Cambus, J P; Nguyen, F; de Graeve, J; Aragon, B; Valdiguie, P

    1994-10-01

    The Electra 800 automatic coagulation analyser rapidly performs most chronometric coagulation tests with high precision. To facilitate data handling, software, adaptable to any PC running under MS-DOS, was written to manage the analyser. Data are automatically collected via the RS232 interface or can be manually input. The software can handle 64 different analyses, all entirely 'user defined'. An 'electronic worksheet' presents the results in pages of ten patients. This enables the operator to assess the data and to perform verifications or complementary tests if necessary. All results outside a predetermined range can be flagged and results can be deleted, modified or added. A patient's previous files can be recalled as the data are archived at the end of the day. A 120 Mb disk can store approximately 130,000 patient files. A daily archive function can print the day's work in alphabetical order. A communication protocol allows connection to a mainframe computer. This program and the user's manual are available on request, free of charge, from the authors.

  15. Spectral dynamics in the B800 band of LH2 from Rhodospirillum molischianum: a single-molecule study

    International Nuclear Information System (INIS)

    Hofmann, Clemens; Aartsma, Thijs J; Michel, Hartmut; Koehler, Juergen

    2004-01-01

    The BChl a absorptions in the B800 spectrum of individual LH2 complexes from Rhodospirillum molischianum show sudden, reversible spectral jumps between a finite number of spectral positions. From our data, we conclude that these fluctuations result from conformational changes of the protein backbone in close vicinity of the chromophores which provides a sensitive tool to monitor local modulations of the pigment-protein interaction

  16. Thermally stimulated currents between 300 K and 800 K in beryllium oxide

    International Nuclear Information System (INIS)

    Martinelli, J.R.

    1979-01-01

    Thermally Stimulated Polarization/Depolarization Currents (ISPC/ISDC) have been measured in ceramic Beryllium Oxide in the temperature range RT-800 K. Specimens dc biased above RT show a Thermoelectret behaviour at RT. The thermal destruction of the thermoelectret state gives rise to a TSDC spectrum with at least three current maxima. Two contributions to the induced polarization are found: one volumetric uniform and another due to space charge formation. These polarizations are related to the impurity content (mainly Si and Al) as well as to the microstructure (average grain size, grain boundary distribution, pore distribution, glassy phases) of the ceramic specimens. Some mechanisms, based on Al 3+ - compensation vacancies and charge carriers transport via grain boundaries (through pore glassy phases) are proposed to explain the observed TSDC Spectra and the electrical conductivity results. (Author) [pt

  17. 800,000 year old mammoth DNA, modern elephant DNA or PCR artefact?

    DEFF Research Database (Denmark)

    Binladen, Jonas; Gilbert, M Thomas P; Willerslev, Eske

    2007-01-01

    Poulakakis and colleagues (Poulakakis et al. 2006: Biol. Lett. 2, 451-454), report the recovery of 'authentic' mammoth DNA from an 800,000-year-old fragment of bone excavated on the island of Crete. In light of results from other ancient DNA studies that indicate how DNA survival is unlikely...... in samples, which are recovered from warm environments and are relatively old (e.g. more than 100,000 years), these findings come as a great surprise. Here, we show that problems exist with the methodological approaches used in the study. First, the nested PCR technique as reported is nonsensical...... polymorphisms. Finally, we demonstrate using a simple BLAST search in GenBank that the claimed 'uniquely derived character state' for mammoths is in fact also found within modern elephants. Udgivelsesdato: 2007-Feb-22...

  18. The mechanical design of a proton microscope for radiography at 800 MeV

    International Nuclear Information System (INIS)

    Valdiviez, R.; Sigler, F.E.; Barlow, D.B.; Blind, B.; Jason, A.J.; Mottershead, C.T.; Gomez, J.J.; Espinoza, C.J.

    2003-01-01

    A proton microscope has been developed for radiography applications using the 800-MeV linear accelerator at the Los Alamos Neutron Science Center (LANSCE). The microscope provides a magnified image of a static device, or of a dynamic event such as a high-speed projectile impacting a target. The microscope assembly consists primarily of four Permanent Magnet Quadrupoles (PMQ's) that are supported on movable platforms. The platform supports, along with the rest of the support structure, are designed to withstand the residual dynamic loads that are expected from the dynamic tests. This paper covers the mechanical design of the microscope assembly, including the remote positioning system that allows for fine-tuning the focus of an object being imaged.

  19. Isolation and evaluation of a high H{sub 2}-producing lab isolate from cow dung

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Anjana; Sinha, Pallavi [Nanotechnology and Molecular Biology Lab, Department of Biotechnology, University of Allahabad, Allahabad-211002, Uttar Pradesh (India); Kotay, Shireen Meher; Das, Debabrata [Department of Biotechnology, Indian Institute of Technology, Kharagpur-721302, West Bengal (India)

    2009-09-15

    Hydrogen producing bacterial strain was isolated from Indian cow dung and identified of the bacterial family Enterobacteriaceae. This lab isolate was differentiated from Citrobacter Y-19 at molecular level by using RAPD, PCR based technique, and OPO-03{sub 460} and OPO-17{sub 800} RAPD marker for this specific strain (lab isolate) was identified. Fermentative studies were investigated for important parameters, starting with pH of the culture, temperature, inoculum age and inoculum volume, initial substrate concentration and different substrates. Among different substrates, dextrose and sucrose were the preferred substrates for hydrogen production. The optimal starting pH of the culture was found to be 5.0. The H{sub 2} production increased with increase in temperature up to 30 C. The maximum value of H{sub 2} production was recorded when inoculum volume was 12.5% of the culture broth and inoculum age was 14 h. Under batch fermentation conditions, the maximum hydrogen production rate and yield were 355.2 ml l{sup -1} h{sup -1} and 2.1 mol/mol glucose (conversion 35%), respectively. These results indicate that this lab isolate is an ideal hydrogen producer. (author)

  20. Final Technical Report - High-Performance, Oxide-Dispersion-Strengthened Tubes for Production of Ethylene adn Other Industrial Chemicals

    Energy Technology Data Exchange (ETDEWEB)

    McKimpson, Marvin G.

    2006-04-06

    This project was undertaken by Michigan Technological University and Special Metals Corporation to develop creep-resistant, coking-resistant oxide-dispersion-strengthened (ODS) tubes for use in industrial-scale ethylene pyrolysis and steam methane reforming operations. Ethylene pyrolysis tubes are exposed to some of the most severe service conditions for metallic materials found anywhere in the chemical process industries, including elevated temperatures, oxidizing atmospheres and high carbon potentials. During service, hard deposits of carbon (coke) build up on the inner wall of the tube, reducing heat transfer and restricting the flow of the hydrocarbon feedstocks. About every 20 to 60 days, the reactor must be taken off-line and decoked by burning out the accumulated carbon. This decoking costs on the order of $9 million per year per ethylene plant, accelerates tube degradation, and requires that tubes be replaced about every 5 years. The technology developed under this program seeks to reduce the energy and economic cost of coking by creating novel bimetallic tubes offering a combination of improved coking resistance, creep resistance and fabricability not available in current single-alloy tubes. The inner core of this tube consists of Incoloy(R) MA956, a commercial ferritic Fe-Cr-Al alloy offering a 50% reduction in coke buildup combined with improved carburization resistance. The outer sheath consists of a new material - oxide dispersion strengthened (ODS) Alloy 803(R) developed under the program. This new alloy retains the good fireside environmental resistance of Alloy 803, a commercial wrought alloy currently used for ethylene production, and provides an austenitic casing to alleviate the inherently-limited fabricability of the ferritic Incoloy(R) MA956 core. To provide mechanical compatibility between the two alloys and maximize creep resistance of the bimetallic tube, both the inner Incoloy(R) MA956 and the outer ODS Alloy 803 are oxide dispersion

  1. Effect of thermal oxidation treatment on pH sensitivity of AlGaN/GaN heterostructure ion-sensitive field-effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lei; Bu, Yuyu [Institute of Science and Technology, Tokushima University, Tokushima 770-8506 (Japan); Li, Liuan, E-mail: liliuan@mail.sysu.edu.cn [School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou 510275 (China); Ao, Jin-Ping, E-mail: jpao@ee.tokushima-u.ac.jp [Institute of Science and Technology, Tokushima University, Tokushima 770-8506 (Japan)

    2017-07-31

    Highlights: • AlGaN/GaN ISFETs were fabricated and evaluated with thermal oxidation treatment. • Sensitivity was improved to 57.7 mV/pH after 700 °C treatment. • Sensitivity became poor after 800 °C treatment. • The pure α-Al{sub 2}O{sub 3} crystal phase generated on the surface of the 700 °C treatment sample. • Ga{sub 2}O{sub 3} phase content in the metal oxide layer increased after 800 °C treatment. - Abstract: In this article, AlGaN/GaN heterostructure ion-sensitive field-effect transistors (ISFETs) were prepared and evaluated by thermal oxidation treatment on the AlGaN surface. The ISFETs were fabricated on the AlGaN/GaN heterostructure and then thermally oxidized with dry oxygen in 600, 700, and 800 °C, respectively. It indicates that the performance of the AlGaN/GaN heterostructure ISFETs, such as noise and sensitivity, has been improved owing to the thermal oxidation treatment process at different temperatures. The X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) results indicate that after thermal oxidation treatment at different temperatures, hydroxide who possesses high surface state density will transfer to oxide owing to the higher chemical stability of the latter. Moreover, a crystalline α-Al{sub 2}O{sub 3} phase generated at 700 °C can not only provide a relatively smooth surface, but also improve the sensitivity to 57.7 mV/pH for the AlGaN/GaN heterostructure ISFETs, which is very close to the Nernstian limit.

  2. Sr{sub 2}CoMoO{sub 6} anode for solid oxide fuel cell running on H{sub 2} and CH{sub 4} fuels

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ping [Engineering Research Center of Nano-GEO Materials of Education Ministry, China University of Geosciences, Wuhan 430074 (China); Texas Materials Institute, ETC 9.102, The University of Texas at Austin, Austin, TX 78712 (United States); Huang, Yun-Hui [Texas Materials Institute, ETC 9.102, The University of Texas at Austin, Austin, TX 78712 (United States); State Key Laboratory of Materials Processing and Die and Mould Technology, School of Materials Science and Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074 (China); Cheng, Jin-Guang; Goodenough, John B. [Texas Materials Institute, ETC 9.102, The University of Texas at Austin, Austin, TX 78712 (United States); Mao, Zong-Qiang [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China)

    2011-02-15

    The double perovskite Sr{sub 2}CoMoO{sub 6-{delta}} was investigated as a candidate anode for a solid oxide fuel cell (SOFC). Thermogravimetric analysis (TGA) and powder X-ray diffraction (XRD) showed that the cation array is retained to 800 C in H{sub 2} atmosphere with the introduction of a limited concentration of oxide-ion vacancies. Stoichiometric Sr{sub 2}CoMoO{sub 6} has an antiferromagnetic Neel temperature T{sub N} {approx} 37 K, but after reduction in H{sub 2} at 800 C for 10 h, long-range magnetic order appears to set in above 300 K. In H{sub 2}, the electronic conductivity increases sharply with temperature in the interval 400 C < T < 500 C due to the onset of a loss of oxygen to make Sr{sub 2}CoMoO{sub 6-{delta}} a good mixed oxide-ion/electronic conductor (MIEC). With a 300-{mu}m-thick La{sub 0.8}Sr{sub 0.12}Ga{sub 0.83}Mg{sub 0.17}O{sub 2.815} (LSGM) as oxide-ion electrolyte and SrCo{sub 0.8}Fe{sub 0.2}O{sub 3-{delta}} as the cathode, the Sr{sub 2}CoMoO{sub 6-{delta}} anode gave a maximum power density of 1017 mW cm{sup -2} in H{sub 2} and 634 mW cm{sup -2} in wet CH{sub 4}. A degradation of power in CH{sub 4} was observed, which could be attributed to coke build up observed by energy dispersive spectroscopy (EDS). (author)

  3. Observation of high-lying resonances in the H sup minus ion

    Energy Technology Data Exchange (ETDEWEB)

    Harris, P.G. (Los Alamos National Lab., NM (USA) New Mexico Univ., Albuquerque, NM (USA). Dept. of Physics and Astronomy)

    1990-05-01

    This dissertation reports the observation of several series of resonances, for which both electrons are in excited states, in the photodetachment cross section of H{sup {minus}}. These {sup 1}P doubly-excited states interfere with the continuum in which they are embedded, and appear as dips in the production cross section of excited neutral hydrogen. The experiment was performed by intersecting an 800 MeV H{sup {minus}} beam with a (266 nm) laser beam at varying angles; the relativistic Doppler shift then tuned'' the photon energy in the barycentric frame. The process was observed by using a magnet strong enough the strip the electrons from the excited hydrogen atoms in selected states n and detecting the resulting protons, which allowed the isolation of the individual n channels. Three resonances are clearly visible in each channel. The data support recent theoretical calculations for the positions of doubly-excited {sup 1}P resonances, and verify a new Rydberg-like formula for the modified Coulomb potential.

  4. Viscosities of cesium vapor to 1,620 K and of liquid gallium to 1,800 K

    International Nuclear Information System (INIS)

    Tippelskirch, H. v.

    1976-01-01

    The viscosity of cesium at 1,620 K and 40 bar has been determined to 41 x 10 -6 (Pa x s) by the oscillating cup method. The saturated vapor density at 1,580 K could be derived from the viscosity measurements. The viscosity of liquid gallium has been determined from 370 K to 1,800 K. The experimental results have been compared with calculations based on the Enskog hard-sphere transport theory for dense fluids. (orig.) [de

  5. 76 FR 24793 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series and RB211 Trent 500, 700, and 800...

    Science.gov (United States)

    2011-05-03

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series and RB211 Trent 500, 700, and 800 Series... the AD. Costs of Compliance Based on the service information, we estimate that this AD would affect...

  6. Neutron spectrum at 900 from 800 MeV (p,n) reactions on a Ta target

    International Nuclear Information System (INIS)

    Howe, S.D.; Lisowski, P.W.; King, N.S.P.; Russell, G.J.; Donnert, H.J.

    1979-01-01

    The neutron time-of-flight spectrum produced by a thick tantalum target bombarded by 800-MeV protons was measured at an angle of 90 0 . The data were taken at the Weapons Neutron Research facility by use of a cylindrical Ta target with a radius of 1.27 cm and a length of 15 cm. An NE-213 liquid scintillator was used to detect the neutrons over an energy range of 0.5 to 350 MeV. The neutron yield is presented and compared to a intranuclear-cascade/evaporation model prediction. 3 figures

  7. Constraints on Primordial Non-Gaussianity from 800 000 Photometric Quasars.

    Science.gov (United States)

    Leistedt, Boris; Peiris, Hiranya V; Roth, Nina

    2014-11-28

    We derive robust constraints on primordial non-Gaussianity (PNG) using the clustering of 800 000 photometric quasars from the Sloan Digital Sky Survey in the redshift range 0.5quasar halo bias at the largest scales, while discarding as little as possible of the data. The standard local-type PNG parameters f_{NL} and g_{NL} both imprint a k^{-2} scale-dependent effect in the bias. Constraining these individually, we obtain -49quasar clustering to the underlying dark matter. These are the strongest constraints obtained to date on PNG using a single population of large-scale structure tracers, and are already at the level of pre-Planck constraints from the cosmic microwave background. A conservative forecast for a Large Synoptic Survey Telescope (LSST)-like survey incorporating mode projection yields σ(f_{NL})∼5-competitive with the Planck result-highlighting the power of upcoming large scale structure surveys to probe the initial conditions of the Universe.

  8. 800-MeV proton irradiation of thorium and depleted uranium targets

    Energy Technology Data Exchange (ETDEWEB)

    Russell, G.J.; Brun, T.O.; Pitcher, E.J. [Los Alamos National Laboratory, NM (United States)] [and others

    1995-10-01

    As part of the Los Alamos Fertile-to-Fissile-Conversion (FERFICON) program in the late 1980`s, thick targets of the fertile materials thorium and depleted uranium were bombarded by 800-MeV protons to produce the fissile materials {sup 233}U and {sup 239}Pu, respectively. The amount of {sup 233}U made was determined by measuring the {sup 233}Pa activity, and the yield of {sup 239}Pu was deduced by measuring the activity of {sup 239}Np. For the thorium target, 4 spallation products and 34 fission products were also measured. For the depleted uranium target, 3 spallation products and 16 fission products were also measured. The number of fissions in each target was deduced from fission product mass-yield curves. In actuality, axial distributions of the products were measured, and the distributions were then integrated over the target volume to obtain the total number of products for each reaction.

  9. Bi[NC5H3(CO2)2](OH2)xF (x=1 and 2): New one-dimensional Bi-coordination materials—Reversible hydration and topotactic decomposition to α-Bi2O3

    International Nuclear Information System (INIS)

    Jeon, Hye Rim; Lee, Dong Woo; Ok, Kang Min

    2012-01-01

    Two one-dimensional bismuth-coordination materials, Bi[NC 5 H 3 (CO 2 ) 2 ](OH 2 ) x F (x=1 and 2), have been synthesized by hydrothermal reactions using Bi 2 O 3 , 2,6-NC 5 H 3 (CO 2 H) 2 , HF, and water at 180 °C. Structures of the two materials were determined by single-crystal X-ray diffraction. Although they have different crystal structures, both Bi-organic materials shared a common structural motif, a one-dimensional chain structure consisting of Bi 3+ cations and pyridine dicarboxylate linkers. Detailed structural analyses include infrared spectroscopy, thermogravimetric analysis, and reversible hydration reactions for the coordinated water molecules were reported. Also, thermal decomposition of the rod-shaped Bi[NC 5 H 3 (CO 2 ) 2 ](OH 2 )F single crystals at 800 °C led to α-Bi 2 O 3 that maintained the same morphology of the original crystals. - Graphical abstract: Calcination of the Bi[NC 5 H 3 (CO 2 ) 2 ](OH 2 )F single crystals at 800 °C results in the α-Bi 2 O 3 rods that maintain the original morphology of the crystals. Highlights: ► Synthesis of one-dimensional chain Bi-organic frameworks. ► Reversible hydration reactions of Bi[NC 5 H 3 (CO 2 ) 2 ](OH 2 )F. ► Topotactic decomposition maintaining the same morphology of the original crystals.

  10. The reaction p12C→ηX from Tp=800 MeV to Tp=1500 MeV

    International Nuclear Information System (INIS)

    Chiavassa, E.; Dellacasa, G.; De Marco, N.; De Oliveira Martins, O.; Gallio, M.; Guaita, P.; Musso, A.; Piccotti, A.; Scomparin, E.; Vercellin, E.

    1998-01-01

    The reaction p 12 C→nX has been studied, at several proton kinetic energies ranging from 800 MeV to 1500 MeV, at the proton synchrotron Saturne at Saclay. The measured doubly differential cross-sections are presented and discussed in the framework of a simple theoretical model. The model fails in describing the deepest subthreshold data while the above-threshold data are fairly well reproduced. (orig.)

  11. Evaluation of Beckman Coulter DxI 800 immunoassay system using clinically oriented performance goals.

    Science.gov (United States)

    Akbas, Neval; Schryver, Patricia G; Algeciras-Schimnich, Alicia; Baumann, Nikola A; Block, Darci R; Budd, Jeffrey R; Gaston, S J Stephen; Klee, George G

    2014-11-01

    We evaluated the analytical performance of 24 immunoassays using the Beckman Coulter DxI 800 immunoassay systems at Mayo Clinic, Rochester, MN for trueness, precision, detection limits, linearity, and consistency (across instruments and reagent lots). Clinically oriented performance goals were defined using the following methods: trueness-published desirable accuracy limits, precision-published desirable biologic variation; detection limits - 0.1 percentile of patient test values, linearity - 50% of total error, and consistency-percentage test values crossing key decision points. Local data were collected for precision, linearity, and consistency. Data were provided by Beckman Coulter, Inc. for trueness and detection limits. All evaluated assays except total thyroxine were within the proposed goals for trueness. Most of the assays met the proposed goals for precision (86% of intra-assay results and 75% of inter-assay results). Five assays had more than 15% of the test results below the minimum detection limits. Carcinoembryonic antigen, total thyroxine and free triiodothyronine exceeded the proposed goals of ±6.3%, ±5% and ±5.7% for dilution linearity. All evaluated assays were within the proposed goals for instrument consistency. Lot-to-lot consistency results for cortisol, ferritin and total thyroxine exceeded the proposed goals of 3.3%, 11.4% and 7% at one medical decision level, while vitamin B12 exceeded the proposed goals of 5.2% and 3.8% at two decision levels. The Beckman Coulter DxI 800 immunoassay system meets most of these proposed goals, even though these clinically focused performance goals represent relatively stringent limits. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Subsolidus Phase Relations of the CaO-WO3-CuO System at 800 °C in Air

    DEFF Research Database (Denmark)

    Grivel, J. -C.

    2012-01-01

    The subsolidus phase relations of the CaO-WO3-CuO system were investigated in air. The samples were equilibrated at 800 degrees C. Under these conditions, five binary oxide phases are stable: Ca2CuO3, Cu3WO6, CuWO4, CaWO4 and Ca3WO6. The pseudo-ternary section is characterised by 6 three...

  13. Effect of deposition temperature and thermal annealing on the dry etch rate of a-C: H films for the dry etch hard process of semiconductor devices

    International Nuclear Information System (INIS)

    Lee, Seung Moo; Won, Jaihyung; Yim, Soyoung; Park, Se Jun; Choi, Jongsik; Kim, Jeongtae; Lee, Hyeondeok; Byun, Dongjin

    2012-01-01

    The effect of deposition and thermal annealing temperatures on the dry etch rate of a-C:H films was investigated to increase our fundamental understanding of the relationship between thermal annealing and dry etch rate and to obtain a low dry etch rate hard mask. The hydrocarbon contents and hydrogen concentration were decreased with increasing deposition and annealing temperatures. The I(D)/I(G) intensity ratio and extinction coefficient of the a-C:H films were increased with increasing deposition and annealing temperatures because of the increase of sp 2 bonds in the a-C:H films. There was no relationship between the density of the unpaired electrons and the deposition temperature, or between the density of the unpaired electrons and the annealing temperature. However, the thermally annealed a-C:H films had fewer unpaired electrons compared with the as-deposited ones. Transmission electron microscopy analysis showed the absence of any crystallographic change after thermal annealing. The density of the as-deposited films was increased with increasing deposition temperature. The density of the 600 °C annealed a-C:H films deposited under 450 °C was decreased but at 550 °C was increased, and the density of all 800 °C annealed films was increased. The dry etch rate of the as-deposited a-C:H films was negatively correlated with the deposition temperature. The dry etch rate of the 600 °C annealed a-C:H films deposited at 350 °C and 450 °C was faster than that of the as-deposited film and that of the 800 °C annealed a-C:H films deposited at 350 °C and 450 °C was 17% faster than that of the as-deposited film. However, the dry etch rate of the 550 °C deposited a-C:H film was decreased after annealing at 600 °C and 800 °C. The dry etch rate of the as-deposited films was decreased with increasing density but that of the annealed a-C:H films was not. These results indicated that the dry etch rate of a-C:H films for dry etch hard masks can be further decreased by

  14. Chirp and temperature effects in parametric down conversion from crystals pumped at 800 nm

    Science.gov (United States)

    Sánchez-Lozano, X.; Wiechers, C.; Lucio, J. L.

    2018-04-01

    We consider spontaneous parametric down conversion from aperiodic poled crystals pumped at 800 nm. Our analyses account the effect of internal and external parameters, where, in the former, we include the crystal chirp and length, while in the latter temperature, also the pump chirp and other beam properties. The typical distribution produced is a pop-tab like structure in frequency-momentum space, and our results show that this system is a versatile light source, appropriated to manipulate the frequency and transverse momentum properties of the light produced. We briefly comment on the potential usefulness of the types of telecom wavelength light produced, in particular for quantum information applications.

  15. Theoretical study of H- stripping with a wiggler magnet

    International Nuclear Information System (INIS)

    Hutson, R.L.

    1991-01-01

    The first step for injecting protons into the LAMPF Proton Storage Ring (PSR) at LANL is to strip a beam of 800-MeV H - ions to H 0 with a 1.8-T dipole magnet. Because of the finite lifetime of energetic H - ions in the magnetic field, their trajectories bend before stripping causing the angular spread of the beam, and therefore its emittance, to grow during the stripping process. In the case of the PSR, the horizontal beam emittance grows by a factor of roughly three during injection. As a consequence, beam losses in the ring are significantly greater than they would be if there were not emittance growth. A speculative technique is proposed in which the beam divergence growth and resulting emittance growth is reduced by stripping the H - in a wiggler magnet whose transverse field alternates in direction as a function of position along the beam axis. The wiggler field configuration is adjusted so that the angular beam spread introduced during passage through one unidirectional-field increment of path is relatively small and so that 99.99% of the beam is stripped after passing through the whole magnet. With careful field design the net added angular beam spread is reduced because the incremental angular spreads are painted back and forth over the same small range. In the hypothetical case described, the calculated emittance growth and beam loss increase are significantly smaller than those calculated for a conventional stripper magnet. 3 refs., 3 figs

  16. Parity nonconservation in the proton-deuteron total cross section at 800 MeV

    International Nuclear Information System (INIS)

    Mischke, R.E.

    1988-01-01

    A measurement of parity nonconservation in the transmission of 800-MeV longitudinally-polarized protons through an unpolarized, one- meter liquid-deuterium target is discussed. The apparatus was essentially that same as for a previous measurement of the effect in p-p scattering. The longitudinal asymmetry is measured from the change in transmission of the beam through the target as the helicity of the beam is reversed. The preliminary result is A/sub L/ = (1.7 +- 0.8(stat) +- 1.0(sys)) /times/ 10/sup /minus/7/. Further study of the dependence of transmission on beam properties should allow the estimate of systematic errors to be reduced and may alter the central value of the result. 11 refs., 2 figs., 1 tab

  17. 21 CFR 800.55 - Administrative detention.

    Science.gov (United States)

    2010-04-01

    ... obtained and confirmed by written memorandum within FDA as soon as possible. (f) Labeling or marking a...) Issuance of detention order. (1) The detention order shall be issued in writing, in the form of a detention... permitted under paragraph (h) of this section, without the written permission of an authorized FDA...

  18. Multiquanta photodetachment from the H- ion

    International Nuclear Information System (INIS)

    Tang, Chen-Yau.

    1992-03-01

    Multiphoton detachment (MPD) of an electron from the loosely bound H - system (binding energy = 0.7542 eV) has been studied at various photon energies and laser intensities. In the center of mass of 800-MeV H - ions the CO 2 laser photon energy, 0.117 eV, was Doppler tuned over a wide range, from 0.15 to 0.39 eV. The peak laser intensity in the lab frame was varied from 2 to 12 GW/cm 2 . The general behavior of MPD versus photon energy and the ac-Stark/pondermotive effects are of special interest in the study. Characteristic threshold structures by absorption of 2, 3, 4, and 5 photons were observed, as evidenced by rapid changes in the signal amplitudes. These thresholds provide a straightforward picture of channel opening in MPD as the photon energy is increased. A fit of two-photon detachment data to the Wigner threshold law showed a good match with a small intensity-induced shift in the threshold energy. A study of laser intensity effects demonstrated departures from the simple power law predicted by lowest-order perturbation theory, which is possibly another indication of pondermotive shifts in the threshold. The absolute MPD rates have been estimated and found to be in fairly good agreement with the results of Floquet theory

  19. Fully automated dual-frequency three-pulse-echo 2DIR spectrometer accessing spectral range from 800 to 4000 wavenumbers

    Energy Technology Data Exchange (ETDEWEB)

    Leger, Joel D.; Nyby, Clara M.; Varner, Clyde; Tang, Jianan; Rubtsova, Natalia I.; Yue, Yuankai; Kireev, Victor V.; Burtsev, Viacheslav D.; Qasim, Layla N.; Rubtsov, Igor V., E-mail: irubtsov@tulane.edu [Department of Chemistry, Tulane University, New Orleans, Louisiana 70118 (United States); Rubtsov, Grigory I. [Institute for Nuclear Research of the Russian Academy of Sciences, Moscow 117312 (Russian Federation)

    2014-08-15

    A novel dual-frequency two-dimensional infrared instrument is designed and built that permits three-pulse heterodyned echo measurements of any cross-peak within a spectral range from 800 to 4000 cm{sup −1} to be performed in a fully automated fashion. The superior sensitivity of the instrument is achieved by a combination of spectral interferometry, phase cycling, and closed-loop phase stabilization accurate to ∼70 as. The anharmonicity of smaller than 10{sup −4} cm{sup −1} was recorded for strong carbonyl stretching modes using 800 laser shot accumulations. The novel design of the phase stabilization scheme permits tuning polarizations of the mid-infrared (m-IR) pulses, thus supporting measurements of the angles between vibrational transition dipoles. The automatic frequency tuning is achieved by implementing beam direction stabilization schemes for each m-IR beam, providing better than 50 μrad beam stability, and novel scheme for setting the phase-matching geometry for the m-IR beams at the sample. The errors in the cross-peak amplitudes associated with imperfect phase matching conditions and alignment are found to be at the level of 20%. The instrument can be used by non-specialists in ultrafast spectroscopy.

  20. La0.8Sr0.2Co0.8Ni0.2O3-δ impregnated oxygen electrode for H2O/CO2 co-electrolysis in solid oxide electrolysis cells

    Science.gov (United States)

    Zheng, Haoyu; Tian, Yunfeng; Zhang, Lingling; Chi, Bo; Pu, Jian; Jian, Li

    2018-04-01

    High-temperature H2O/CO2 co-electrolysis through reversible solid oxide electrolysis cell (SOEC) provides potentially a feasible and eco-friendly way to convert electrical energy into chemicals stored in syngas. In this work, La0.8Sr0.2Co0.8Ni0.2O3-δ (LSCN) impregnated Gd0.1Ce0.9O1.95 (GDC)-(La0.8Sr0.2)0.95MnO3-δ (LSM) composite oxygen electrode is studied as high-performance electrode for H2O/CO2 co-electrolysis. The LSCN impregnated cell exhibits competitive performance with the peak power density of 1057 mW cm-2 at 800 °C in solid oxide fuel cell (SOFC) mode; in co-electrolysis mode, the current density can reach 1.60 A cm-2 at 1.5 V at 800 °C with H2O/CO2 ratio of 2/1. With LSCN nanoparticles dispersed on the surface of GDC-LSM to maximize the reaction active sites, the LSCN impregnated cell shows significant enhanced electrochemical performance at both SOEC and SOFC modes. The influence of feed gas composition (H2O-H2-CO2) and operating voltages on the performance of co-electrolysis are discussed in detail. The cell shows a very stable performance without obvious degradation for more than 100 h. Post-test characterization is analyzed in detail by multiple measurements.

  1. Stress corrosion cracking of candidate materials for nuclear waste containers

    International Nuclear Information System (INIS)

    Maiya, P.S.; Shack, W.J.; Kassner, T.F.

    1989-09-01

    Types 304L and 316L stainless steel (SS), Incoloy 825, Cu, Cu-30%Ni, and Cu-7%Al have been selected as candidate materials for the containment of high-level nuclear waste at the proposed Yucca Mountain Site in Nevada. The susceptibility of these materials to stress corrosion cracking has been investigated by slow-strain-rate tests (SSRTs) in water which simulates that from well J-13 (J-13 water) and is representative of the groundwater present at the Yucca Mountain site. The SSRTs were performed on specimens exposed to simulated J-13 water at 93 degree C and at a strain rate 10 -7 s -1 under crevice conditions and at a strain rate of 10 -8 s -1 under both crevice and noncrevice conditions. All the tests were interrupted after nominal elongation strains of 1--4%. Examination by scanning electron microscopy showed some crack initiation in virtually all specimens. Optical microscopy of metallographically prepared transverse sections of Type 304L SS suggests that the crack depths are small (<10 μm). Preliminary results suggest that a lower strain rate increases the severity of cracking of Types 304L and 316L SS, Incoloy 825, and Cu but has virtually no effect on Cu-30%Ni and Cu-7%Al. Differences in susceptibility to cracking were evaluated in terms of a stress ratio, which is defined as the ratio of the increase in stress after local yielding in the environment to the corresponding stress increase in an identical test in air, both computed at the same strain. On the basis of this stress ratio, the ranking of materials in order of increasing resistance to cracking is: Types 304L SS < 316L SS < Incoloy 825 congruent Cu-30%Ni < Cu congruent Cu-7%Al. 9 refs., 12 figs., 7 tabs

  2. Fuel component of electricity generation cost for the BN-800 reactor with MOX fuel and uranium oxide fuel with increasing of fuel burnup and removing of radial breeding blanket

    International Nuclear Information System (INIS)

    Raskach, A.

    2001-01-01

    Nowadays there are two completed design concepts of Nuclear Power Plants (NPPs) with the BN-800 type reactors developed with due regard for advanced safety requirements. One of them is the design of the fourth unit of the Beloyarsk Nuclear Power Plant; the other one is the design of three units of the South Ural Nuclear Power Plant. The both concepts are to use mixed oxide fuel (MOX fuel) based on civil plutonium. Studies on any project include economical analyses and cost of fuel is an essential parameter. In the course of the design works on the both projects such evaluations were done. For BN-800 on the Beloyarsk site nuclear fuel costs were taken from actual expenses of the BN-600 reactor and converted to rated thermal power and design capacity factor of the BN-800 and then increased by 20% in connection with turning to MOX fuel. Then this methodology was rewarding, but the ratio of uranium fuel and MOX fuel costs might change for the last years. For the project of three units of the South Ural Nuclear Power Plant nuclear fuel expenses were calculated from the data on a MOX fuel fabrication production facility (Complex-300). However, investigations performed recently shown that the methodology of economical assessments should be revised, as well as design and technology of MOX fuel fabrication at Complex-300 should be revised to meet all the existing safety requirements. Excepting there is a great bulk of civil plutonium to be reproduced, now we came up against the problem to utilize the exceeding ex-weapons plutonium that obviously can be used for MOX fuel fabrication as well. Construction of the MOX fuel fabrication facility - Complex-300 - was started in 1983. Its design output was planned to provide simultaneously 4 fast reactors of the BN-800 type with MOX fuel. By now about 50% of construction works (taking into account auxiliary buildings and arrangements) and 20% of installation works have been done at Complex-300. Along this, first works to construct

  3. Subsolidus phase relations of the SrO–WO3–CuO system at 800 °C in air

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude; Norby, Poul

    2012-01-01

    The subsolidus phase relations of the SrO–WO3–CuO system were investigated in air. The samples were equilibrated at 800 °C. Under these conditions, eight binary oxides are stable. The pseudo-ternary section contains two ternary oxide phases: the previously described Sr2CuWO6 phase as well as a new...

  4. 75 FR 8928 - Announcement of IS-GPS-200, IS-GPS-705, IS-GPS-800 Interface Control Working Group (ICWG...

    Science.gov (United States)

    2010-02-26

    ... DEPARTMENT OF DEFENSE Department of the Air Force Announcement of IS-GPS-200, IS-GPS-705, IS-GPS... document/s IS-GPS-200E (NAVSTAR GPS Space Segment/Navigation User Interfaces), IS-GPS-705A (NAVSTAR GPS Space Segment/User Segment L5 Interfaces), and IS-GPS-800A (NAVSTAR GPS Space Segment/User Segment L1C...

  5. Examination of the Effects of Activated Carbon Produced from Coal Using Single-Step H3PO4/N2+H2O Vapor Activation on the Adsorption of Bovine Serum Albumin at Different Temperatures and pH Values

    Directory of Open Access Journals (Sweden)

    Atakan Toprak

    2017-12-01

    Full Text Available This study examined protein adsorption equilibrium and kinetics on activated carbon (AC that we obtained from coal by single-step H3PO4 activation under N2+H2O vapor at 800 °C. Surface properties, pore size distribution, and volumes of AC were determined using the volumetric method with N2 adsorption at 77 K. Also, the textural properties were characterized by SEM-EDAX and XRD. The zeta potential values were measured to elucidate the electrostatic interactions between the protein and AC. The obtained AC discrete system was also used as an adsorbent for adsorbing bovine serum albumin (BSA from aqueous solution. The effects of pH (4.0, 5.0, and 7.4 and temperatures (20, 30 and 40 °C on the adsorption of BSA on AC were examined. The surface area, micropore, mesopore and total pore volumes of AC were found to be 1175 m2/g, 0.477 cm3/g, 0.061 cm3/g and 0.538 cm3/g, respectively. The optimum temperature for AC in BSA adsorption was found to be 40 °C and the pH was found to be 4.0. The highest BSA adsorption was found to be 159 mg/g and pH to be 4.0. The experimental equilibrium data were compared with the Langmuir and Freundlich models and found to be compatible with both models. The adsorption process is best described by the pseudo-first-order kinetic model. As a result, it was found out that AC obtained by single step H3PO4/N2+H2O vapor activation is an effective adsorbent for the adsorption of BSA from aqueous solution.

  6. Examination of steam generator alloy 800 NG tube from the Almaraz unit 2 NPP

    International Nuclear Information System (INIS)

    Diego, G. de; Gomez Briceno, D.; Maffiotte, C.; Baladia, M.; Arias, C.J.

    2015-01-01

    The steam generators of Almaraz Unit 2 were replaced in 1997 by the model 61W/D3 (Siemens) with Alloy 800NG steam generator tubes. Denting indications were firstly detected in 2006 in the SG-3. Crack indications were identified in 2009. At the end of 2011, three tubes were recovered from this steam generator to carry out destructive examination in order to identify the root cause of the tubes degradation. Analysis of deposits point out the existence of multiples elements in the removed OD (Outer Diameter) deposits as well as in the deposits at the free tube under sludge and at the transition zone. Deposits are more abundant at the transition zone than at free tube. About 10% Na concentration has been detected, whereas S and Cl appear in small concentrations. Si appears regularly and Cr, Ni concentrations in the deposits are similar. Multiple intergranular cracks have been detected at 3 mm above the last contact point between the tube and the TS (tube support), in a band of around 5 mm, practically in the whole perimeter of the tube. Fracture surface of crack-B was partially covered by a Si rich layer, whereas fracture surface of crack-A seems to be cleaner. However, no significant differences in composition, except higher amount of S in crack-B, were found in the deposits of both cracks. EDX mapping and Auger profiles point out Ni enrichment with slight Cr enrichment or depletion and Fe depletion. The comparison of Auger profiles with available results for Alloy 800 tested in caustic and acid sulfate environments seems to indicate that the environment inside the cracks detected in the tube R67C48 is neutral or moderately caustic

  7. Compact high efficiency, light weight 200-800 MHz high power RF source

    International Nuclear Information System (INIS)

    Shrader, M.B.; Preist, D.H.

    1985-01-01

    There has long been a need for a new more efficient less bulky high power RF power source to drive accelerators in the 200 to 800 MHz region. Results on a recent 5-year EIMAC sponsored R and D program which have lead to the introduction of the Klystrode for UHF television and troposcatter applications indicate that at power levels of 1MW or more efficiencies in excess of 75% can be obtained at 450 MHz. Efficiencies of this order coupled with potential size and weight parameters which are a fraction of those of existing high power UHF generators open up new applications which heretofore would have been impractical if not impossible. Measurements at 470 MHz on existing Klystrodes are given. Projected operating conditions for a 1MW 450 MHz Klystrode having an overall length of 60 inches and a total tube, circuit, and magnet weight of 250 pounds is presented

  8. Molecular origins and consequences of High-800 LH2 in Roseobacter denitrificans.

    Science.gov (United States)

    Duquesne, Katia; Blanchard, Cecile; Sturgis, James N

    2011-08-09

    Roseobacter denitrificans is a marine bacterium capable of using a wide variety of different metabolic schemes and in particular is an anoxygenic aerobic photosynthetic bacterium. In the work reported here we use a deletion mutant that we have constructed to investigate the structural origin of the unusual High-800 light-harvesting complex absorption in this bacterium. We suggest that the structure is essentially unaltered when compared to the usual nonameric complexes but that a change in the environment of the C(13:1) carbonyl group is responsible for the change in spectrum. We tentatively relate this change to the presence of a serine residue in the α-polypeptide. Surprisingly, the low spectral overlap between the peripheral and core light-harvesting systems appears not to compromise energy collection efficiency too severely. We suggest that this may be at the expense of maintaining a low antenna size. © 2011 American Chemical Society

  9. Chronological evidence fails to support claim of an isochronous widespread layer of cosmic impact indicators dated to 12,800 years ago

    Science.gov (United States)

    Meltzer, David J.; Holliday, Vance T.; Cannon, Michael D.; Miller, D. Shane

    2014-05-01

    According to the Younger Dryas Impact Hypothesis (YDIH), ∼12,800 calendar years before present, North America experienced an extraterrestrial impact that triggered the Younger Dryas and devastated human populations and biotic communities on this continent and elsewhere. This supposed event is reportedly marked by multiple impact indicators, but critics have challenged this evidence, and considerable controversy now surrounds the YDIH. Proponents of the YDIH state that a key test of the hypothesis is whether those indicators are isochronous and securely dated to the Younger Dryas onset. They are not. We have examined the age basis of the supposed Younger Dryas boundary layer at the 29 sites and regions in North and South America, Europe, and the Middle East in which proponents report its occurrence. Several of the sites lack any age control, others have radiometric ages that are chronologically irrelevant, nearly a dozen have ages inferred by statistically and chronologically flawed age-depth interpolations, and in several the ages directly on the supposed impact layer are older or younger than ∼12,800 calendar years ago. Only 3 of the 29 sites fall within the temporal window of the YD onset as defined by YDIH proponents. The YDIH fails the critical chronological test of an isochronous event at the YD onset, which, coupled with the many published concerns about the extraterrestrial origin of the purported impact markers, renders the YDIH unsupported. There is no reason or compelling evidence to accept the claim that a cosmic impact occurred ∼12,800 y ago and caused the Younger Dryas.

  10. Subsurface methane formation in graphite due to exposure to H+ and D+

    International Nuclear Information System (INIS)

    Chiu, S.; Haasz, A.A.

    1994-01-01

    The extent of H-D mixing in the form of mixed-isotope methane formation during simultaneous H + /D + bombardment of graphite was measured and found to be a sensitive function of H + -D + ion range separation. The result strongly supports the model that methane molecules are formed at the end of ion range in the bulk of graphite. A long steadily decreasing transient was observed in the methane emission when bombarding a virgin graphite sample with 10 keV D + at 800 K. The effect was less pronounced for low density fine grain isographites (EK98) than for high density pyrolytic graphite (HPG99) and monocrystal carbons. We propose a model which attributes this transient to the creation of new internal ''surfaces'', formed during ion irradiation along with ion-created micropaths. The increase in internal surface area effectively ''dilutes'' the inner surface hydrogen concentration in the region where incident hydrogen ions thermalize. We propose that, initially, methane molecules are formed mainly on inherent internal surfaces (pore and grain/crystallite boundary surfaces) in the region where hydrogen ions thermalize; then as damage builds up, newly produced internal ''surfaces'' also contribute to methane formation. (orig.)

  11. Crack growth under combined creep and fatigue conditions in alloy 800

    International Nuclear Information System (INIS)

    Pfaffelhuber, M.; Roedig, M.; Schubert, F.; Nickel, H.

    1989-08-01

    To investigate the crack growth behaviour under combined creep-fatigue loading, CT 25 mm-specimens of X10NiCrAlTi 32 20 (Alloy 800) have been tested in experiments with cyclic loadings and hold times, with static loadings and short stress rekief interrupts, with ramp type loadings and with sequences of separate fatigue and creep crack growth periods. The test temperature of 700deg C was selected because only in this temperature range this alloy provides similar amounts of crack growth under creep and fatigue conditions due to equivalent stress levels. For the estimation of crack growth under combined loading conditions a linear accumulation of increase in crack length was proved using the crack growth laws of pure creep and fatigue crack growth. Hold time and ramp loadings lead to a higher crack growth rate compared with pure creep or pure fatigue crack growth tests. In hold time experiments the crack growth rate is higher than ramp tests of the same period time. The results of hold time tests can be fairly enough predicted by linear damage accumulation rules. (orig.) [de

  12. In situ pH within particle beds of bioactive glasses.

    Science.gov (United States)

    Zhang, Di; Hupa, Mikko; Hupa, Leena

    2008-09-01

    The in vitro behavior of three bioactive glasses with seven particle size distributions was studied by measuring the in situ pH inside the particle beds for 48h in simulated body fluid (SBF). After immersion, the surface of the particles was characterized with a field emission scanning electron microscope equipped with an energy-dispersive X-ray analyzer. In addition, the results were compared with the reactions of the same glasses formed as plates. A similar trend in pH as a function of immersion time was observed for all systems. However, the pH inside the particle beds was markedly higher than that in the bulk SBF of the plates. The pH decreased as power functions with increasing particle size, i.e. with decreasing surface area. The in vitro reactivity expressed as layer formation strongly depended on the particle size and glass composition. The average thickness of the total reaction layer decreased with the increase in sample surface area. Well-developed silica and calcium phosphate layers typically observed on glass plates could be detected only on some particles freely exposed to the solution. No distinct reaction layers were observed on the finest particles, possibly because the layers spread out on the large surface area. Differences in the properties of the bulk SBF and the solution inside the particle bed were negligible for particles larger than 800microm. The results enhance our understanding of the in vitro reactions of bioactive glasses in various product forms and sizes.

  13. Effect of chloride and sulphate ions on the electrochemical corrosion behavior of alloy 800NG in PWR secondary water environment at 250 deg C

    International Nuclear Information System (INIS)

    Mansur, Fabio A.; Schvartzman, Monica Maria de A.M.; Quinan, Marco A.D.; Soares, Antonio E.G.; Nogueira, Pedro Henrique B.O.

    2013-01-01

    Alloy 800NG (nuclear grade) is used in nuclear steam generators (SG) as the tubing material for pressurized water reactors (PWRs) because of its high corrosion resistance. The corrosion resistance is due to the protective character of the oxide film formed on the tube surface by contact with the high temperature pressurized water. Nevertheless, corrosion has been the major cause of tube failures in nuclear SGs. The existing experience of different nuclear power plants shows that the water chemistry has an important role in maintaining the integrity of the protective oxide films. Many of such problems have been attributed to secondary side water chemistry conditions and excursions, many of which have been resulted from condenser cooling water ingress. Alloy 800 is known to undergo passivity breakdown and pitting in the presence of chloride ions under oxidative water conditions. In this work the effect of chloride and sulphate ions at various concentrations on the corrosion behavior of Alloy 800 tube at 250 deg C was investigated using the potentiodynamic anodic polarization technique. An active-passive transition occurred at 250 deg C in all studied conditions and the oxide film grown on surface showed greater porosity and lower resistance to localised corrosion in all studied conditions. (author)

  14. Conceptual core model for the reactor core test

    International Nuclear Information System (INIS)

    Swenson, L.D.

    1970-01-01

    Several design options for the ZrH Flight System Reactor were investigated which involved tradeoffs of core excess reactivity, reactor control, coolant mixing and cladding thickness. A design point was selected which is to be the basis for more detailed evaluation in the preliminary design phase. The selected design utilizes 295 elements with 0.670 inch element-to-element pitch, 32 mil thick Incoloy cladding, 18.00 inches long fuel meat, hydrogen content of 6.3 x 10 22 atoms/cc fuel, 10.5 w/o uranium, and a spiraled fin configuration with alternate elements having fins with spiral to the right, spiral to the left, and no fin at all (R-L-N fin configuration). Fin height is 30 mils for the center region of the core and 15 mils for the outer region. (U.S.)

  15. Numerical-experimental investigation of load paths in DP800 dual phase steel during Nakajima test

    Science.gov (United States)

    Bergs, Thomas; Nick, Matthias; Feuerhack, Andreas; Trauth, Daniel; Klocke, Fritz

    2018-05-01

    Fuel efficiency requirements demand lightweight construction of vehicle body parts. The usage of advanced high strength steels permits a reduction of sheet thickness while still maintaining the overall strength required for crash safety. However, damage, internal defects (voids, inclusions, micro fractures), microstructural defects (varying grain size distribution, precipitates on grain boundaries, anisotropy) and surface defects (micro fractures, grooves) act as a concentration point for stress and consequently as an initiation point for failure both during deep drawing and in service. Considering damage evolution in the design of car body deep drawing processes allows for a further reduction in material usage and therefore body weight. Preliminary research has shown that a modification of load paths in forming processes can help mitigate the effects of damage on the material. This paper investigates the load paths in Nakajima tests of a DP800 dual phase steel to research damage in deep drawing processes. Investigation is done via a finite element model using experimentally validated material data for a DP800 dual phase steel. Numerical simulation allows for the investigation of load paths with respect to stress states, strain rates and temperature evolution, which cannot be easily observed in physical experiments. Stress triaxiality and the Lode parameter are used to describe the stress states. Their evolution during the Nakajima tests serves as an indicator for damage evolution. The large variety of sheet metal forming specific load paths in Nakajima tests allows a comprehensive evaluation of damage for deep drawing. The results of the numerical simulation conducted in this project and further physical experiments will later be used to calibrate a damage model for simulation of deep drawing processes.

  16. Orbital and millennial-scale features of atmospheric CH4 over the past 800,000 years.

    Science.gov (United States)

    Loulergue, Laetitia; Schilt, Adrian; Spahni, Renato; Masson-Delmotte, Valérie; Blunier, Thomas; Lemieux, Bénédicte; Barnola, Jean-Marc; Raynaud, Dominique; Stocker, Thomas F; Chappellaz, Jérôme

    2008-05-15

    Atmospheric methane is an important greenhouse gas and a sensitive indicator of climate change and millennial-scale temperature variability. Its concentrations over the past 650,000 years have varied between approximately 350 and approximately 800 parts per 10(9) by volume (p.p.b.v.) during glacial and interglacial periods, respectively. In comparison, present-day methane levels of approximately 1,770 p.p.b.v. have been reported. Insights into the external forcing factors and internal feedbacks controlling atmospheric methane are essential for predicting the methane budget in a warmer world. Here we present a detailed atmospheric methane record from the EPICA Dome C ice core that extends the history of this greenhouse gas to 800,000 yr before present. The average time resolution of the new data is approximately 380 yr and permits the identification of orbital and millennial-scale features. Spectral analyses indicate that the long-term variability in atmospheric methane levels is dominated by approximately 100,000 yr glacial-interglacial cycles up to approximately 400,000 yr ago with an increasing contribution of the precessional component during the four more recent climatic cycles. We suggest that changes in the strength of tropical methane sources and sinks (wetlands, atmospheric oxidation), possibly influenced by changes in monsoon systems and the position of the intertropical convergence zone, controlled the atmospheric methane budget, with an additional source input during major terminations as the retreat of the northern ice sheet allowed higher methane emissions from extending periglacial wetlands. Millennial-scale changes in methane levels identified in our record as being associated with Antarctic isotope maxima events are indicative of ubiquitous millennial-scale temperature variability during the past eight glacial cycles.

  17. Polarization observables D/sub NN/, P and A for vector pp → vector pπ+n at 800 MeV

    International Nuclear Information System (INIS)

    Bonner, B.E.; McNaughton, M.W.; van Dyck, O.B.

    1983-01-01

    In conjunction with a vector polarization transfer measurement in the vector pp → vector dπ + reaction, we also obtained data on polarization observables for vector pp → vector pπ + n at 800 MeV incident proton energy. Scattered protons were detected in a spectrometer at angles from 5 0 to 11 0 . Pions were detected in coincidence at angles 80 0 to 130 0 . The proton momentum range covered was from 800 to 1300 MeV/c. The prominent peak observed near 1150 MeV/c in the proton spectrum is a reflection of Δ ++ production at center of mass angles from 0 0 to 30 0 . Regions of the spectrum corresponding to Δ ++ production at backward THETA/sub cm/ angles and to the 1 S 0 np final state interaction fall below the momentum acceptance limit for the spectrometer setting used in the present measurements. The events were binned into five proton momentum bins for the determination of the polarization observables D/sub NN/, P, and A

  18. Visible learning a synthesis of over 800 meta-analyses relating to achievement

    CERN Document Server

    Hattie, John A C

    2009-01-01

    This unique and ground-breaking book is the result of 15 years research and synthesises over 800 meta-analyses on the influences on achievement in school-aged students. It builds a story about the power of teachers, feedback, and a model of learning and understanding. The research involves many millions of students and represents the largest ever evidence based research into what actually works in schools to improve learning. Areas covered include the influence of the student, home, school, curricula, teacher, and teaching strategies. A model of teaching and learning is developed based on the notion of visible teaching and visible learning. A major message is that what works best for students is similar to what works best for teachers - an attention to setting challenging learning intentions, being clear about what success means, and an attention to learning strategies for developing conceptual understanding about what teachers and students know and understand. Although the current evidence based fad has turn...

  19. Universal description of inelastic and non(single)-diffractive multiplicity distributions in pp collisions at 250, 360 and 800 GeV/c

    International Nuclear Information System (INIS)

    Krasznovszky, S.; Wagner, I.

    1987-06-01

    A distribution function is proposed for multiplicity in accordance with the stochastic number evolution. This function gives a universal description of inelastic and nondiffractive multiplicity distributions in pp collisions at 250, 360 and 800 GeV/c. The negative binomial distribution fails in the description of inelastic data. (author)

  20. Analytical evaluation of the environment effect on creep rupture strength

    International Nuclear Information System (INIS)

    Tamura, Manabu; Ogawa, Yutaka; Kurata, Yuji; Kondo, Tatsuo

    1982-04-01

    An analytical approach was made in evaluating semi-quantitatively the effect of environment on rupture strength of materials. In the analysis the zone formed in the material by reaction with the environment was assumed to bear the applied load as one of the strength members. In calculations a law of mixtures of creep strength and the linear damage rule were applied. In the modeling of the load bearing by the composite structure of the environment-affected and intact zones, both parallel and series models were considered to formulate the equations. The equation for the parallel-loaded model was properly adopted in explaining semi-quantitatively the case of Incoloy alloy 800 crept in air, which was strengthened with the layer formed by nitrization. The equation for the serially loaded model was more successfully adopted to the evaluation of the rupture strength of dissimilar weld joints. The latter was also considered to be potentially adoptable to the problems of the effect of specimen size and shape on rupture strength, which had been often taken into account in evaluating the environment effect. For application of the developed method, examination was made to the possible decrease in rupture strength of Hastelloy alloy XR in long term tests by the formation of Cr depleted zone due to oxidation in HTGR impure helium, and the results were compared with the values obtained by experiments. (author)