WorldWideScience

Sample records for included column chromatography

  1. Monolithic column in gas chromatography.

    Science.gov (United States)

    Kurganov, A

    2013-05-02

    Monolithic columns invented in chromatographic praxis almost 40 years ago gained nowadays a lot of popularity in separations by liquid chromatographic technique. At the same time, application of monolithic columns in gas chromatography is less common and only a single review published by Svec et al. covers this field of research. Since that time a lot of new findings on application and properties of monolithic columns in gas chromatography have been published in the literature deserving consideration and discussion. This review considers preparation of monolithic columns for GC, an impact of preparation conditions on column performance, optimization of separation conditions for GC analysis on monolithic columns and other important aspects of preparation and usage of monolithic capillary columns in GC. A final part of the review discusses the modern trends and possible applications in the future of capillary monolithic columns in GC. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Temperature programmable microfabricated gas chromatography column

    Science.gov (United States)

    Manginell, Ronald P.; Frye-Mason, Gregory C.

    2003-12-23

    A temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by the integration of a resistive heating element and temperature sensing on the microfabricated column. Additionally, means are provided to thermally isolate the heated column from their surroundings. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  3. Inert carriers for column extraction chromatography

    International Nuclear Information System (INIS)

    Katykhin, G.S.

    1978-01-01

    Inert carriers used in column extraction chromatography are reviewed. Such carriers are devided into two large groups: hydrophilic carriers which possess high surface energy and are well wetted only with strongly polar liquids (kieselguhrs, silica gels, glasses, cellulose, Al 2 O 3 ) and water-repellent carriers which possess low surface energy and are well wetted with various organic solvents (polyethylene, polytetrafluorethylene polytrifluorochlorethylene). Properties of various carriers are presented: structure, chemical and radiation stability, adsorption properties, extracting agent capacity. The effect of structure and sizes of particles on the efficiency of chromatography columns is considered. Ways of immovable phase deposition on the carrier and the latter's regeneration. Peculiarities of column packing for preparative and continuous chromatography are discussed

  4. "Dry-column" chromatography of plant pigments

    Science.gov (United States)

    Woeller, F. H.; Lehwalt, M. F.; Oyama, V. I.

    1973-01-01

    Separation of plant pigments which can be accomplished on thin-layer silica plates with mixture of petroleum ether, halocarbon, acetone, and polar solvent can be readily translated into dry-column technique that yields reproducible chromatograms after elution in fashion of liquid chromatography with fluorimeter as detector. Best solvent system was found to be mixture of petroleum ether, dichloromethane, acetone, and ethyl acetate.

  5. Column-to-column packing variation of disposable pre-packed columns for protein chromatography.

    Science.gov (United States)

    Schweiger, Susanne; Hinterberger, Stephan; Jungbauer, Alois

    2017-12-08

    In the biopharmaceutical industry, pre-packed columns are the standard for process development, but they must be qualified before use in experimental studies to confirm the required performance of the packed bed. Column qualification is commonly done by pulse response experiments and depends highly on the experimental testing conditions. Additionally, the peak analysis method, the variation in the 3D packing structure of the bed, and the measurement precision of the workstation influence the outcome of qualification runs. While a full body of literature on these factors is available for HPLC columns, no comparable studies exist for preparative columns for protein chromatography. We quantified the influence of these parameters for commercially available pre-packed and self-packed columns of disposable and non-disposable design. Pulse response experiments were performed on 105 preparative chromatography columns with volumes of 0.2-20ml. The analyte acetone was studied at six different superficial velocities (30, 60, 100, 150, 250 and 500cm/h). The column-to-column packing variation between disposable pre-packed columns of different diameter-length combinations varied by 10-15%, which was acceptable for the intended use. The column-to-column variation cannot be explained by the packing density, but is interpreted as a difference in particle arrangement in the column. Since it was possible to determine differences in the column-to-column performance, we concluded that the columns were well-packed. The measurement precision of the chromatography workstation was independent of the column volume and was in a range of±0.01ml for the first peak moment and±0.007 ml 2 for the second moment. The measurement precision must be considered for small columns in the range of 2ml or less. The efficiency of disposable pre-packed columns was equal or better than that of self-packed columns. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  6. Design, testing, and simulation of microscale gas chromatography columns

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, M.L.; Kottenstette, R.; Matzke, C.M.; Frye-Mason, G.C.; Shollenberger, K.A.; Adkins, D.R.; Wong, C.C.

    1998-08-01

    A microscale gas chromatography column is one component in a microscale chemistry laboratory for detecting chemical agents. Several columns were fabricated using the Bosch etch process which allows deep, high aspect ratio channels of rectangular cross-section. A design tool, based on analytical models, was developed to evaluate the effects of operating conditions and column specifications on separation resolution and time. The effects of slip flow, channel configuration, and cross-sectional shape were included to evaluate the differences between conventional round, straight columns and the microscale rectangular, spiral columns. Experimental data were obtained and compared with the predicted flowrates and theoretical number of plates. The design tool was then employed to select more optimum channel dimensions and operating conditions for high resolution separations.

  7. Microchip-based monolithic column for high performance liquid chromatography

    Data.gov (United States)

    National Aeronautics and Space Administration — We have developed microchip based monolithic columns that can be used for liquid chromatography of small organic molecules, as well as, macromolecules such as...

  8. Direct probing of chromatography columns by laser-induced fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    McGuffin, V.L.

    1992-12-07

    This report summarizes the progress and accomplishments of this research project from September 1, 1989 to February 28, 1993. During this period, we have accomplished all of the primary scientific objectives of the research proposal: (1) constructed and evaluated a laser-induced fluorescence detection system that allows direct examination of the chromatographic column, (2) examined nonequilibrium processes that occur upon solute injection and elution, (3) examined solute retention in liquid chromatography as a function of temperature and pressure, (4) examined solute zone dispersion in liquid chromatography as a function of temperature and pressure, and (5) developed appropriate theoretical models to describe these phenomena. In each of these studies, substantial knowledge has been gained of the fundamental processes that are responsible for chromatographic separations. In addition to these primary research objectives, we have made significant progress in three related areas: (1) examined pyrene as a fluorescent polarity probe insupercritical fluids and liquids as a function of temperature and pressure, (2) developed methods for the class-selective identification of polynuclear aromatic hydrocarbons in coal-derived fluids by microcolumn liquid chromatography with fluorescence quenching detection, and (3) developed methods for the determination of saturated and unsaturated (including omega-3) fatty acids in fish oil extracts by microcolumn liquid chromatography with laser-induced fluorescence detection. In these studies, the advanced separation and detection techniques developed in our laboratory are applied to practical problems of environmental and biomedical significance.

  9. Coupling of column liquid chromatography and Fourier transform infrared spectrometry

    NARCIS (Netherlands)

    Somsen, G.W; Gooijer, C; Velthorst, N.H; Brinkman, U.A Th

    1998-01-01

    This paper provides an extensive overview of the literature on the coupling of column liquid chromatography (LC) and Fourier transform infrared spectrometry (FT-IR). Flow-cell-based FT-IR detection and early solvent-elimination interfaces for LC-FT-IR are discussed in brief. A comprehensive

  10. Column Chromatography To Obtain Organic Cation Sorption Isotherms.

    Science.gov (United States)

    Jolin, William C; Sullivan, James; Vasudevan, Dharni; MacKay, Allison A

    2016-08-02

    Column chromatography was evaluated as a method to obtain organic cation sorption isotherms for environmental solids while using the peak skewness to identify the linear range of the sorption isotherm. Custom packed HPLC columns and standard batch sorption techniques were used to intercompare sorption isotherms and solid-water sorption coefficients (Kd) for four organic cations (benzylamine, 2,4-dichlorobenzylamine, phenyltrimethylammonium, oxytetracycline) with two aluminosilicate clay minerals and one soil. A comparison of Freundlich isotherm parameters revealed isotherm linearity or nonlinearity was not significantly different between column chromatography and traditional batch experiments. Importantly, skewness (a metric of eluting peak symmetry) analysis of eluting peaks can establish isotherm linearity, thereby enabling a less labor intensive means to generate the extensive data sets of linear Kd values required for the development of predictive sorption models. Our findings clearly show that column chromatography can reproduce sorption measures from conventional batch experiments with the benefit of lower labor-intensity, faster analysis times, and allow for consistent sorption measures across laboratories with distinct chromatography instrumentation.

  11. Highly stable surface modification of hypercrosslinked monolithic capillary columns and their application in hydrophilic interaction chromatography.

    Science.gov (United States)

    Škeříková, Veronika; Urban, Jiří

    2013-09-01

    A two-step surface modification of poly(styrene-co-vinylbenzyl chloride-co-divinylbenzene) monolithic stationary phases, including hypercrosslinking and thermally initiated surface grafting of [2-(methacryloyloxy)ethyl]dimethyl(3-sulfopropyl)ammonium hydroxide, has been used to prepare capillary columns for the isocratic separation of small polar compounds in hydrophilic interaction chromatography (HILIC). The prepared monolithic columns provided a dual retention mechanism, combining RP and hydrophilic interaction chromatography, controlled by the composition of the mobile phase. By the optimization of the surface grafting reaction using response surface methodology, we have found that the grafting time is the main synergistic effect controlling the retention of polar compounds in HILIC. The prepared monolithic columns achieved long column lifetimes and did not lose their separation power following >10,000 injections. Finally, hypercrosslinked columns have been used in the 1- and 2D LC of phenolic compounds. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Evaluating two process scale chromatography column header designs using CFD.

    Science.gov (United States)

    Johnson, Chris; Natarajan, Venkatesh; Antoniou, Chris

    2014-01-01

    Chromatography is an indispensable unit operation in the downstream processing of biomolecules. Scaling of chromatographic operations typically involves a significant increase in the column diameter. At this scale, the flow distribution within a packed bed could be severely affected by the distributor design in process scale columns. Different vendors offer process scale columns with varying design features. The effect of these design features on the flow distribution in packed beds and the resultant effect on column efficiency and cleanability needs to be properly understood in order to prevent unpleasant surprises on scale-up. Computational Fluid Dynamics (CFD) provides a cost-effective means to explore the effect of various distributor designs on process scale performance. In this work, we present a CFD tool that was developed and validated against experimental dye traces and tracer injections. Subsequently, the tool was employed to compare and contrast two commercially available header designs. © 2014 American Institute of Chemical Engineers.

  13. Robust naphthyl methacrylate monolithic column for high performance liquid chromatography of a wide range of solutes.

    Science.gov (United States)

    Jonnada, Murthy; El Rassi, Ziad

    2015-08-28

    An organic monolithic column based on the co-polymerization of 2-naphthyl methacrylate (NAPM) as the functional monomer and trimethylolpropane trimethacrylate (TRIM) as the crosslinker was introduced for high performance reversed-phase liquid chromatography (RPC). The co-polymerization was performed in situ in a stainless steel column of 4.6mm i.d. in the presence of a ternary porogen consisting of 1-dodecanol and cyclohexanol. This monolithic column (referred to as naphthyl methacrylate monolithic column or NMM column) showed high mechanical stability at relatively high mobile phase flow velocity indicating that the column has excellent hydrodynamic characteristics. To characterize the NMM column, different probe molecules including alkyl benzenes, and aniline, benzene, toluene and phenol derivatives were chromatographed on the column and the results in terms of k, selectivity and plate counts were compared to those obtained on an octadecyl silica (ODS) column in order to assess the presence of π-π and hydrophobic interactions on the NMM column under otherwise the same elution conditions. The NMM column offered additional π-π interactions with aromatic molecules in addition to hydrophobic interactions under RPC elution conditions. Run-to-run and column-to-column reproducibility of solute k values were evaluated, and percent relative standard deviation of column using shallow (30min at 1.0mL/min), steep (10min at 1.0mL/min) and ultra steep (1min at 3.0mL/min) linear gradient elution at increasing ACN concentration in the mobile phase using a 10cm×4.6mm i.d. column in case of shallow and steep linear gradients and a 3cm×4.6mm i.d. column for ultra steep linear gradient. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Ideal versus real automated twin column recycling chromatography process.

    Science.gov (United States)

    Gritti, Fabrice; Leal, Mike; McDonald, Thomas; Gilar, Martin

    2017-07-28

    The full baseline separation of two compounds (selectivity factors αcolumn of any length given the pressure limitations of current LC instruments. The maximum efficiency is that of an infinitely long column operated at infinitely small flow rates. It is determined by the maximum allowable system pressure, the column permeability (particle size), the viscosity of the eluent, and the intensity of the effective diffusivity of the analytes along the column. Alternatively, the twin-column recycling separation process (TCRSP) can overcome the efficiency limit of the single-column approach. In the TCRSP, the sample mixture may be transferred from one to a second (twin) column until its band has spread over one column length. Basic theory of chromatography is used to confirm that the speed-resolution performance of the TCRSP is intrinsically superior to that of the single-column process. This advantage is illustrated in this work by developing an automated TCRSP for the challenging separation of two polycyclic aromatic hydrocarbon (PAH) isomers (benzo[a]anthracene and chrysene) in the reversed-phase retention mode at pressure smaller than 5000psi. The columns used are the 3.0mm×150mm column packed with 3.5μm XBridge BEH-C 18 material (α=1.010) and the 3.0mm or 4.6mm×150mm columns packed with the same 3.5μm XSelect HSST 3 material (α=1.025). The isocratic mobile phase is an acetonitrile-water mixture (80/20, v/v). Remarkably, significant differences are observed between the predicted retention times and efficiencies of the ideal TCRSP (given by the number of cycles multiplied by the retention time and efficiency of one column) and those of the real TCRSP. The fundamental explanation lies in the pressure-dependent retention of these PAHs or in the change of their partial molar volume as they are transferred from the mobile to the stationary phase. A revisited retention and efficiency model is then built to predict the actual performance of real TCRSPs. The

  15. Boron isotope fractionation in column chromatography with glucamine type fibers

    International Nuclear Information System (INIS)

    Sonoda, Akinari; Makita, Yoji; Hirotsu, Takahiro

    2008-01-01

    Glucamine type polymers have specific affinity toward boric acid and borate ion. Among them, Chelest Fiber GRY-L showed larger fractionation for boron isotopes than other polymers in our previous study. For this study, we used Chelest Fibers with different fiber lengths (1.0 mm, 0.5 mm, and 0.3 mm) as column packing materials to perform chromatographic separation of boron isotopes. The shorter fiber has larger packing density when packed into the column using a dry method. The 0.3-mm-long fiber has a larger backpressure than fibers of other lengths. Boron adsorption capacities were measured using the breakthrough operation. At this time, the 0.5-mm-long fiber showed the highest capacity. When we measured the isotope ratio profile for fibers of different length using column chromatography, 0.5-mm-long fibers displayed the highest boron isotope fractionation. The 0.5-mm-long fiber is promising as a packing material of column chromatography for boron isotope separation. We also changed operation methods. The lower eluent concentration and the slower flow rate are suitable for boron isotope separation. (author)

  16. Environmental Conditions Influencing Sorption of Inorganic Anions to Multiwalled Carbon Nanotubes Studied by Column Chromatography.

    Science.gov (United States)

    Metzelder, Florian; Schmidt, Torsten C

    2017-05-02

    Sorption to carbon-based nanomaterials is typically studied in batch experiments. An alternative method offering advantages to study sorption is column chromatography. Sorbent packed columns are used and sorption data are determined by relating sorbate retention to that of a nonretarded tracer. We have now for the first time applied this technique to study the influence of environmental conditions on sorption of inorganic anions (bromide, nitrite, nitrate, and iodide) to multiwalled carbon nanotubes. Deuterium oxide was used as nonretarded tracer. Sorption isotherms were best described by the Freundlich model. Sorption increased in the order bromide 4.5 the surface charge was negative, but sorption was still detectable at pH 6 and 9. Consequently, other forces than electrostatic attraction contributed to sorption. These forces may include H-bonding as indicated by sorption enthalpy determined by variation of column temperature. Overall, column chromatography represents a promising alternative in sorption studies to reveal sorbent properties.

  17. Evaluation of a silicon oxynitride hydrophilic interaction liquid chromatography column in saccharide and glycoside separations.

    Science.gov (United States)

    Wan, Huihui; Sheng, Qianying; Zhong, Hongmin; Guo, Xiujie; Fu, Qing; Liu, Yanfang; Xue, Xingya; Liang, Xinmiao

    2015-05-01

    The retention characteristics of a silicon oxynitride stationary phase for carbohydrate separation were studied in hydrophilic interaction chromatography mode. Four saccharides including mono-, di-, and trisaccharides were employed to investigate the effects of water content and buffer concentration in the mobile phase on hydrophilic interaction liquid chromatography retention. For the tested saccharides, the silicon oxynitride column demonstrated excellent performance in terms of separation efficiency, hydrophilicity, and interesting separation selectivity for carbohydrates compared to the bare silica stationary phase. Finally, the silicon oxynitride hydrophilic interaction liquid chromatography column was employed in the separation of complex samples of fructooligosaccharides, saponins, and steviol glycoside from natural products. The resulting chromatograms demonstrated good separation efficiency and longer retention compared with silica, which further confirmed the advantages and potential application of silicon oxynitride stationary phase for hydrophilic interaction liquid chromatography separation. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Electronic Nose using Gas Chromatography Column and Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Hari Agus Sujono

    2011-08-01

    Full Text Available The conventional electronic nose usually consists of an array of dissimilar chemical sensors such as quartz crystal microbalance (QCM combined with pattern recognition algorithm such as Neural network. Because of parallel processing, the system needs a huge number of sensors and circuits which may emerge complexity and inter-channel crosstalk problems. In this research, a new type of odor identification which combines between gas chromatography (GC and electronic nose methods has been developed. The system consists of a GC column and a 10-MHz quartz crystal microbalance sensor producing a unique pattern for an odor in time domain. This method offers advantages of substantially reduced size, interferences and power consumption in comparison to existing odor identification system. Several odors of organic compounds were introduced to evaluate the selectivity of the system. Principle component analysis method was used to visualize the classification of each odor in two-dimensional space. This system could resolve common organic solvents, including molecules of different classes (aromatic from alcohols as well as those within a particular class (methanol from ethanol and also fuels (premium from pertamax. The neural network can be taught to recognize the odors tested in the experiment with identification rate of 85 %. It is therefore the system may take the place of human nose, especially for poisonous odor evaluations.

  19. Design and control of integrated chromatography column sequences.

    Science.gov (United States)

    Andersson, Niklas; Löfgren, Anton; Olofsson, Marianne; Sellberg, Anton; Nilsson, Bernt; Tiainen, Peter

    2017-07-01

    To increase the productivity in biopharmaceutical production, a natural step is to introduce integrated continuous biomanufacturing which leads to fewer buffer and storage tanks, smaller sizes of integrated unit operations, and full automation of the operation. The main contribution of this work is to illustrate a methodology for design and control of a downstream process based on integrated column sequences. For small scale production, for example, pre-clinical studies, integrated column sequences can be implemented on a single chromatography system. This makes for a very efficient drug development platform. The proposed methodology is composed of four steps and is governed by a set of tools, that is presented, that makes the transition from batch separations to a complete integrated separation sequence as easy as possible. This methodology, its associated tools and the physical implementation is presented and illustrated on a case study where the target protein is separated from impurities through an integrated four column sequence. This article shows that the design and control of an integrated column sequence was successfully implemented for a tertiary protein separation problem. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:923-930, 2017. © 2017 American Institute of Chemical Engineers.

  20. Applications of monolithic columns in liquid chromatography-based clinical chemistry assays.

    Science.gov (United States)

    Bunch, Dustin R; Wang, Sihe

    2011-08-01

    Monolithic columns have slowly been applied to HPLC methods for clinical chemistry testing in the last 10 years. The application areas include therapeutic drug monitoring, drugs of abuse, vitamins, porphyrins, and steroids. In comparison with conventional particulate columns, the monolithic columns may offer shorter chromatography time, more robustness, and better resolution for certain analytes. The potential drawback of large mobile phase consumption may be improved with smaller id columns, which are currently on the market. Methods covered in this review are those searchable in PubMed up to December 2010. This review highlights the emergence of monolithic column technology in HPLC methods used for clinical chemistry testing. The goals of this review are threefold: (i) To identify the areas of clinical chemistry that analytical monolithic columns have been used in HPLC methods. (ii) To demonstrate the application of analytical monolithic columns in HPLC methods using different detection systems. (iii) To discuss the advantages and limitations of the monolithic columns compared with particulate columns in the clinical chemistry applications. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Column properties and flow profiles of a flat, wide column for high-pressure liquid chromatography.

    Science.gov (United States)

    Mriziq, Khaled S; Guiochon, Georges

    2008-04-11

    The design and the construction of a pressurized, flat, wide column for high-performance liquid chromatography (HPLC) are described. This apparatus, which is derived from instruments that implement over-pressured thin layer chromatography, can carry out only uni-dimensional chromatographic separations. However, it is intended to be the first step in the development of more powerful instruments that will be able to carry out two-dimensional chromatographic separations, in which case, the first separation would be a space-based separation, LC(x), taking place along one side of the bed and the second separation would be a time-based separation, LC(t), as in classical HPLC but proceeding along the flat column, not along a tube. The apparatus described consists of a pressurization chamber made of a Plexiglas block and a column chamber made of stainless steel. These two chambers are separated by a thin Mylar membrane. The column chamber is a cavity which is filled with a thick layer (ca. 1mm) of the stationary phase. Suitable solvent inlet and outlet ports are located on two opposite sides of the sorbent layer. The design allows the preparation of a homogenous sorbent layer suitable to be used as a chromatographic column, the achievement of effective seals of the stationary phase layer against the chamber edges, and the homogenous flow of the mobile phase along the chamber. The entire width of the sorbent layer area can be used to develop separations or elute samples. The reproducible performance of the apparatus is demonstrated by the chromatographic separations of different dyes. This instrument is essentially designed for testing detector arrays to be used in a two-dimensional LC(x) x LC(t) instrument. The further development of two-dimension separation chromatographs based on the apparatus described is sketched.

  2. Second dimension column ensemble pressure tuning in comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Sharif, Khan M; Kulsing, Chadin; Junior, Ademario I da Silva; Marriott, Philip J

    2018-02-09

    A pressure tunable (PT) coupled column ensemble has been implemented for the second dimension ( 2 D) separation in comprehensive two dimensional gas chromatography (GC×PTGC). This process requires two columns to be connected by a pressure junction, as a replacement for a single narrow bore, short column in 2 D. Various 2 D 1 and 2 D 2 columns may be selected to provide complementary selectivity (polarity) compared to the 1 D column. The tunable residence time arising from differential pressure drop in each 2 D column results in a tunable fractional contribution of each column in the 2 D separation. A sample mixture comprising different chemical classes, including alkanes and alcohols, is used to identify the feasibility and extent of selectivity tuning possible in GC×PTGC. The column length is also varied due to the imposed challenge of wraparound in the PT coupled column system as pressures are adjusted in the 2 D separation. Different experimental parameters, stationary phase materials and column lengths have been applied to investigate and understand the separation behaviour of the 2 D PT coupled column GC×GC system. Results are discussed considering analyte retention time, peak width, linear velocity and the contribution of each 2 D column. A specific and unexpected example of GC×GC separation was demonstrated where the peak positions of polar and apolar compounds could almost swap their 2 D retention position by application of PT. Kerosene was analysed as an example of complex sample analysis by GC×PTGC system. This process is shown to be a practical approach for altering different stationary phase selectivities in a single 2 D arrangement in GC×GC. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Measurement of dihydro testosterone by radioimmunoassay after celite column chromatography

    International Nuclear Information System (INIS)

    Lando, V.S.

    1992-01-01

    A method for measuring dihydro testosterone after celite column chromatography is developed. One milliliter of serum containing 1000 cpm of tritiated dihydro testosterone was extracted with hexane: ethyl acetate (2:3): dried, diluted with non saturated iso octane and injected in the column previously washed with 3.5 ml of pure iso octane. The serum was eluted from the column with pure iso octane (3.5 ml) followed by 5% ethyl acetate in iso octane. The quantity of tritiated dihydro testosterone which was recovered ranged from 50% to 80% in all assays. The sensitivity of the method was 4 ng/d l. The intra-assay variation was less than 9% and the inter-assay variation was less than 9,7%. It was measured dihydro testosterone, testosterone and testosterone/dihydro testosterone ratio in the following groups: Group 1- forty-one normal adult subjects in basal conditions, Group 2 - six normal adult subjects, evaluated in basal conditions and after stimulus with 6000 International Unity of human Chorionic Gonadotropin; Group 3- six pre-puberal children with unilateral cryptochidism. Group 4- eight patients with male pseudo hermaphroditism due to 5-alpha-reductase deficiency in basal conditions and after HCG. (author)

  4. Optimization and simulation of tandem column supercritical fluid chromatography separations using column back pressure as a unique parameter.

    Science.gov (United States)

    Wang, Chunlei; Tymiak, Adrienne A; Zhang, Yingru

    2014-04-15

    Tandem column supercritical fluid chromatography (SFC) has demonstrated to be a useful technique to resolve complex mixtures by serially coupling two columns of different selectivity. The overall selectivity of a tandem column separation is the retention time weighted average of selectivity from each coupled column. Currently, the method development merely relies on extensive screenings and is often a hit-or-miss process. No attention is paid to independently adjust retention and selectivity contributions from individual columns. In this study, we show how tandem column SFC selectivity can be optimized by changing relative dimensions (length or inner diameter) of the coupled columns. Moreover, we apply column back pressure as a unique parameter for SFC optimization. Continuous tuning of tandem column SFC selectivity is illustrated through column back pressure adjustments of the upstream column, for the first time. In addition, we show how and why changing coupling order of the columns can produce dramatically different separations. Using the empirical mathematical equation derived in our previous study, we also demonstrate a simulation of tandem column separations based on a single retention time measurement on each column. The simulation compares well with experimental results and correctly predicts column order and back pressure effects on the separations. Finally, considerations on instrument and column hardware requirements are discussed.

  5. Preparation and characterization of alkyl methacrylate-based monolithic columns for capillary gas chromatography applications.

    Science.gov (United States)

    Yusuf, Kareem; Aqel, Ahmad; A L Othman, Zeid; Badjah-Hadj-Ahmed, Ahmed Yacine

    2013-08-02

    Gas chromatography (GC) is considered the least common application of both polymer and silica-based monolithic columns. This study describes the fabrication of alkyl methacrylate monolithic materials for use as stationary phases in capillary gas chromatography. Following the deactivation of the capillary surface with 3-(trimethoxysilyl)propyl methacrylate (TMSM), the monoliths were formed by the co-polymerization of either hexyl methacrylate (HMA) or lauryl methacrylate (LMA) with different percentage of ethylene glycol dimethacrylate (EDMA) in presence of an initiator (azobisisobutyronitrile, AIBN) and a mixture of porogens include 1-propanol, 1,4-butanediol and water. The monoliths were prepared in 500mm length capillaries possessing inner diameters of 250μm. The efficiencies of the monolithic columns for low molecular weight compounds significantly improved as the percentage of crosslinker was increased, because of the greater proportion of pores less than 50nm. The columns containing lower percentages of crosslinker were able to rapidly separate a series of 8 alkane members in 0.7min, but the separation was less efficient for the light alkanes. Columns prepared with the lauryl methacrylate monomer yielded a different morphology for the monolith-interconnected channels. The channels were more branched, which increased the separation time, and unlike the other columns, allowed for temperature programming. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Column liquid chromatography-ultraviolet and column liquid chromatography/mass spectrometry evaluation of stress degradation behavior of escitalopram oxalate.

    Science.gov (United States)

    Dhaneshwar, Sunil R; Mahadik, Mahadeo V; Kulkarni, Mahesh J

    2009-01-01

    The objective of this work was to study the degradation behavior of escitalopram oxalate under different International Conference on Harmonization (ICH)-recommended stress conditions by column liquid chromatography (LC)-UV and LC/mass spectrometry (LC/MS) and to establish a validated stability-indicating LC assay method. Escitalopram oxalate was subjected to stress conditions of hydrolysis, oxidation, photolysis, and thermal decomposition. Extensive degradation was found to occur in alkaline medium. Mild degradation was observed in acidic and oxidative conditions. Escitalopram oxalate was stable to neutral, photolytic, and thermal stress. Successful separation of the drug from degradation products formed under stress conditions was achieved on a PerfectSil-100 ODS-3 column [C18 (5 microm, 25 cm x 4.6 mm id)] using methanol-0.01 M acetate buffer pH 3.8 adjusted with acetic acid (45 + 55) as the mobile phase. The flow rate was 1 ml/min, and the detection wavelength was 239 nm. The method was validated according to ICH guidelines. Major degradation products formed in hydrolysis and oxidative conditions were isolated, and structural elucidation of degradation products was done by LCIMS and infrared spectrometry studies. The major hydrolysis degradation product was confirmed as 1-(3-dimethylaminopropyl)-1-(4-fluoro- phenyl)-1,3dihydroisobenzofuran-5-carboxylic acid, and the major oxidative degradation product was confirmed as 1-{[3-dimethylamino(oxide)- propyl]-1-(4-fluro-phenyl)}-1,3-dihydro-isobenzofuran- 5-carbonitrile.

  7. X-ray computed tomography of packed bed chromatography columns for three dimensional imaging and analysis.

    Science.gov (United States)

    Johnson, T F; Levison, P R; Shearing, P R; Bracewell, D G

    2017-03-03

    Physical characteristics critical to chromatography including geometric porosity and tortuosity within the packed column were analysed based upon three dimensional reconstructions of bed structure in-situ. Image acquisition was performed using two X-ray computed tomography systems, with optimisation of column imaging performed for each sample in order to produce three dimensional representations of packed beds at 3μm resolution. Two bead materials, cellulose and ceramic, were studied using the same optimisation strategy but resulted in differing parameters required for X-ray computed tomography image generation. After image reconstruction and processing into a digital three dimensional format, physical characteristics of each packed bed were analysed, including geometric porosity, tortuosity, surface area to volume ratio as well as inter-bead void diameters. Average porosities of 34.0% and 36.1% were found for ceramic and cellulose samples and average tortuosity readings at 1.40 and 1.79 respectively, with greater porosity and reduced tortuosity overall values at the centre compared to the column edges found in each case. X-ray computed tomography is demonstrated to be a viable method for three dimensional imaging of packed bed chromatography systems, enabling geometry based analysis of column axial and radial heterogeneity that is not feasible using traditional techniques for packing quality which provide an ensemble measure. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  8. Intact-protein trapping columns for proteomic analysis in capillary high-performance liquid chromatography.

    Science.gov (United States)

    Guan, Xia; Yan, Guoquan; Gao, Mingxia; Hong, Guangfeng; Deng, Chunhui; Zhang, Xiangmin

    2010-10-29

    A new type of monolithic trapping columns with high mechanical strength was prepared by thin-layer sol-gel coating method and applied to trapping intact proteins for on-line capillary liquid chromatography. Monolithic trapping columns were fabricated by entrapping C8 reversed-phase particles into the capillary columns through a sol-gel network, which was formed by hydrolysis and polycondensation of methyltriethoxysilane. Hundreds times of trapping/untrapping for intact proteins were carried out. The trapping columns showed long-term stability up to 300 bar. Recovery, loading capacity and reproducibility of trapping columns were evaluated using four proteins. The recovery of four protein mixtures for the C8 monolithic trapping columns was 99.3% on average. The loading capacity of 5 mm × 320 μm i.d. C8 trapping columns for the protein mixtures was 30 μg. Day-to-day relative standard deviation (RSD) values for recoveries of protein mixtures on the same C8 trapping column ranged from 2.34 to 5.87%, column-to-column RSD values were from 3.01 to 6.81%. The C8 trapping columns were used to trap normal mouse liver intact proteins in a capillary liquid chromatography system. Results demonstrated high efficiency of the monolithic trapping columns for trapping intact proteins for proteomic analysis in on-line capillary liquid chromatography system. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Ready-made chromatography columns for extracellular vesicle isolation from plasma.

    Science.gov (United States)

    Welton, Joanne Louise; Webber, Jason Paul; Botos, Laur-Alexandru; Jones, Michael; Clayton, Aled

    2015-01-01

    Proteomic studies of circulating vesicles are hampered by difficulties in purifying vesicles from plasma and serum. Isolations are contaminated with high-abundance blood proteins that may mask genuine vesicular-associated proteins and/or simply provide misleading data. In this brief report, we explored the potential utility of a commercially available size exclusion chromatography column for rapid vesicle purification. We evaluated the performance of the column, with cancer cell line conditioned medium or healthy donor plasma, in terms of removing non-vesicular protein and enriching for vesicles exhibiting exosome characteristics. Serial fractions revealed a peak for typical exosomal proteins (CD9, CD81 etc.) that preceded the peak for highly abundant proteins, including albumin, for either sample type, and harvesting only this peak would represent elimination of >95% of protein from the sample. The columns showed good reproducibility, and streamlining the workflow would allow the exosome-relevant material to be collected in less than 10 minutes. Surprisingly, however, subsequent post-column vesicle concentration steps whilst resulting in some protein loss also lead to low vesicle recoveries, with a net effect of reducing sample purity (assessed by the particle-to-protein ratio). The columns provide a convenient, reproducible and highly effective means of eliminating >95% of non-vesicular protein from biological fluid samples such as plasma.

  10. Ready-made chromatography columns for extracellular vesicle isolation from plasma

    Directory of Open Access Journals (Sweden)

    Joanne Louise Welton

    2015-03-01

    Full Text Available Proteomic studies of circulating vesicles are hampered by difficulties in purifying vesicles from plasma and serum. Isolations are contaminated with high-abundance blood proteins that may mask genuine vesicular-associated proteins and/or simply provide misleading data. In this brief report, we explored the potential utility of a commercially available size exclusion chromatography column for rapid vesicle purification. We evaluated the performance of the column, with cancer cell line conditioned medium or healthy donor plasma, in terms of removing non-vesicular protein and enriching for vesicles exhibiting exosome characteristics. Serial fractions revealed a peak for typical exosomal proteins (CD9, CD81 etc. that preceded the peak for highly abundant proteins, including albumin, for either sample type, and harvesting only this peak would represent elimination of >95% of protein from the sample. The columns showed good reproducibility, and streamlining the workflow would allow the exosome-relevant material to be collected in less than 10 minutes. Surprisingly, however, subsequent post-column vesicle concentration steps whilst resulting in some protein loss also lead to low vesicle recoveries, with a net effect of reducing sample purity (assessed by the particle-to-protein ratio. The columns provide a convenient, reproducible and highly effective means of eliminating >95% of non-vesicular protein from biological fluid samples such as plasma.

  11. Histone fractionation by high-performance liquid chromatography on cyanoalkylsilane (CN) reverse-phase columns

    International Nuclear Information System (INIS)

    Gurley, L.R.; Prentice, D.A.; Valdez, J.G.; Spall, W.D.

    1983-01-01

    Previous work described conditions for the rapid fractionation of histones by high-performance liquid chromatography (HPLC) using a reverse-phase μBondapak C 18 column. That procedure resolved the major classes of histones with one exception: the more hydrophobic H2A variant, (MHP)H2A, was not resolved from the H4 histone class. This report extends that work describing experiments using a μBondapak CN column which better resolves the classes of histones from each other including the resolution of (MHP)H2A from the H4. In addition, the less hydrophobic H2A variant, (LHP)H2A, is partially resolved from the (MHP)H2A, and the less hydrophobic H3 variant, (LHP)H3, is resolved from the more hydrophobic H3 variant, (MHP)H3. Lower trifluoroacetic acid (TFA) concentrations (0.1%) in the eluting water/acetonitrile solvent were used with the CN column than were used with the C 18 column which increased the sensitivity of histone detection by ultraviolet absorption at 206 nm. Greater than 95% of the total [ 3 H]lysine-labeled protein applied to the CN column was eluted from the column. Contaminating nonhistone proteins were found to chromatograph in the region of histone elution. These were greatly reduced by isolating nuclei prior to histone preparation. The fractionation of the histones appears to be based on the hydrophobic properties of the proteins. The histone fractions (identified by their electrophoretic mobilities) were eluted from the CN column in the following order: H1, H2B, (LHP)H2A, (MHP)H2A, H4, (LHP)H3, and (MHP)H3. Phosphorylated and acetylated histone species were not resolved from their unmodified parental species

  12. The development of an evaluation method for capture columns used in two-dimensional liquid chromatography.

    Science.gov (United States)

    Cao, Liwei; Yu, Danhua; Wang, Xinliang; Ke, Yanxiong; Jin, Yu; Liang, Xinmiao

    2011-11-07

    Capture columns are important interface tools for on line two-dimensional liquid chromatography (2D-LC). In this study, a systematic method was developed to evaluate and optimize the capture ability of capture columns by off-line method. First, the parameter Δt(R) (Δt(R)=t(2)-t(1)-t(0)-W) was introduced to quantitatively represent the capture ability of the capture column by connecting a capture column behind the first dimensional column. Based on the value of Δt(R), an appropriate capture column was selected after the first dimensional column was fixed. Then, the capture ability of the selected column was promoted by adjusting the mobile phase of the first dimensional column. Capture ability was also optimized using complex sample analysis software system (CSASS) software. Second, the elution mode of the trapped compounds on the capture column was investigated by connecting the capture column before the second dimensional column. More specifically, in mode I, capture column was connected to the second dimension without changing the flow rate direction and the trapped compounds must pass through the capture column and be eluted into the second dimensional column. The contrary connection mode was mode II. It was found that mode I is more suitable method for 2D-LC. Finally, an off-line reversed-phase/hydrophilic interaction liquid chromatography two-dimensional liquid chromatography (RP/HILIC 2D-LC) system with a C18 capture column was developed to demonstrate the practical application of this method. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Safety operation of chromatography column system with discharging hydrogen radiolytically generated

    Directory of Open Access Journals (Sweden)

    Watanabe Sou

    2015-01-01

    Full Text Available In the extraction chromatography system, accumulation of hydrogen gas in the chromatography column is suspected to lead to fire or explosion. In order to prevent the hazardous accidents, it is necessary to evaluate behaviors of gas radiolytically generated inside the column. In this study, behaviors of gas inside the extraction chromatography column were investigated through experiments and Computation Fluid Dynamics (CFD simulation. N2 gas once accumulated as bubbles in the packed bed was hardly discharged by the flow of mobile phase. However, the CFD simulation and X-ray imaging on γ-ray irradiated column revealed that during operation the hydrogen gas generated in the column was dissolved into the mobile phase without accumulation and discharged.

  14. Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification

    Science.gov (United States)

    Murphy, Patrick J. M.; Stone, Orrin J.; Anderson, Michelle E.

    2011-01-01

    In contrast to other chromatographic methods for purifying proteins (e.g. gel filtration, affinity, and ion exchange), hydrophobic interaction chromatography (HIC) commonly requires experimental determination (referred to as screening or "scouting") in order to select the most suitable chromatographic medium for purifying a given protein 1. The method presented here describes an automated approach to scouting for an optimal HIC media to be used in protein purification. HIC separates proteins and other biomolecules from a crude lysate based on differences in hydrophobicity. Similar to affinity chromatography (AC) and ion exchange chromatography (IEX), HIC is capable of concentrating the protein of interest as it progresses through the chromatographic process. Proteins best suited for purification by HIC include those with hydrophobic surface regions and able to withstand exposure to salt concentrations in excess of 2 M ammonium sulfate ((NH4)2SO4). HIC is often chosen as a purification method for proteins lacking an affinity tag, and thus unsuitable for AC, and when IEX fails to provide adequate purification. Hydrophobic moieties on the protein surface temporarily bind to a nonpolar ligand coupled to an inert, immobile matrix. The interaction between protein and ligand are highly dependent on the salt concentration of the buffer flowing through the chromatography column, with high ionic concentrations strengthening the protein-ligand interaction and making the protein immobile (i.e. bound inside the column) 2. As salt concentrations decrease, the protein-ligand interaction dissipates, the protein again becomes mobile and elutes from the column. Several HIC media are commercially available in pre-packed columns, each containing one of several hydrophobic ligands (e.g. S-butyl, butyl, octyl, and phenyl) cross-linked at varying densities to agarose beads of a specific diameter 3. Automated column scouting allows for an efficient approach for determining which HIC media

  15. Q Sepharose micro-column chromatography: A simple screening method for identifying beta thalassemia traits and hemoglobin E carriers.

    Science.gov (United States)

    Wong, Peerapon; Sritippayawan, Suchila; Suwannakhon, Narutchala; Tapprom, Akamon; Deoisares, Rawisut; Sanguansermsri, Torpong

    2016-11-01

    For beta thalassemia control program in pregnancy, mass screening of the carrier state by determination of the hemoglobin (Hb) A 2 and Hb E proportions and mutation analysis is a preferred method for making prenatal diagnoses. Q Sepharose micro-column chromatography, developed for the determination of Hb A 2 and Hb E for screening purposes, was compared with high performance liquid chromatography (HPLC) to ascertain its relative accuracy and reliability. Results using Q Sepharose micro-column chromatography in 350 blood specimens, including 50 samples genetically proven to be beta thalassemia heterozygotes, were compared to HPLC for validation. An additional study was conducted to test a clinical application on a large-scale survey for beta thalassemia in 1581 pregnant women and their spouses. The mean (±SD) Hb A 2 proportions in the normal and genetically proven beta thalassemia heterozygotes were 2.70±0.40% and 6.30±1.23%, respectively, as determined by Q-Sepharose micro-column chromatography, and 2.65±0.31% and 5.37±0.96%, respectively, as determined by HPLC. The mean Hb E proportions in the Hb E heterozygotes were 23.25±4.13% and 24.72±3.5% as determined by Q Sepharose micro-column chromatography and HPLC, respectively. In the large-scale survey for beta thalassemia, 23 at risk couples were detected. Seven affected fetuses were identified by prenatal diagnosis. Q Sepharose micro-column chromatography was found to be reliable, reproducible and well-suited for large-scale surveys. Additionally, by being reusable and convenient, this simple and economical chromatography method may be an alternative means to screen for beta thalassemia and Hb E carriers in the mass population. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Pressure-dependent boron isotopic fractionation observed by column chromatography

    Science.gov (United States)

    Musashi, M.; Oi, T.; Matsuo, M.; Nomura, M.

    2007-12-01

    Boron isotopic fractionation factor ( S ) between boron taken up in strongly basic anion exchange resin and boron in aqueous solution was determined by breakthrough column chromatography at 5 and 17 MPa at 25°C, using 0.1 mmol/L boric acid solution as feed solution. The S values obtained were 1.018 and 1.012, respectively, which were smaller than the value reported by using the same chromatographic method at atmospheric pressure at 25°C with the boron concentration of 10 mmol/L, but were larger than the values at the same condition with much higher concentration of 100 and 501 mmol/L, indicating that borate-polymerization reducing the isotopic fractionation was negligible. However, calculations based on the theory of isotope distribution between two phases estimated that 21% (5MPa) and 47% (17MPa) of boron taken up in the resin phase was in the three-coordinated B(OH)3-form, instead of in the four-coordinated B(OH)4--form, at high pressures even with the very diluted solution. We discussed this discrepancy by introducing (1) hydration or (2) a partial molar volume difference between isotopic molecules. It was inferred that borate ions were partially dehydrated upon transfer from the solution phase to the resin phase at high pressures, which resulted in smaller S values compared with those at the atmospheric pressure. Alternatively, it was likely that the S value decreased with increasing pressure, because the difference of the partial isotopic molar volumes between 10B(OH)3 and 11B(OH)3 was larger than that between 10B(OH)4- and 11B(OH)4-. If either will be the case, the influence of a pressure upon the isotope effect may not be negligible for boron isotopic exchange equilibrium. This knowledge is crucial for the principle of the boron isotopic pH-metry reconstructing a chemical variation at the paleo-deep oceanic environment where the early life may have been evolved.

  17. Multivariate data analysis to characterize gas chromatography columns for dioxin analysis.

    Science.gov (United States)

    Do, Lan; Geladi, Paul; Haglund, Peter

    2014-06-20

    Principal component analysis (PCA) was applied for evaluating the selectivity of 22 GC columns for which complete retention data were available for the 136 tetra- to octa-chlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Because the hepta- and octa-homologues are easy to separate the PCA was focused on the 128 tetra- to hexa-CDD/Fs. The analysis showed that 21 of the 22 GC columns could be subdivided into four groups with different selectivity. Group I consists of columns with non-polar thermally stable phases (Restek 5Sil MS and Dioxin 2, SGE BPX-DXN, Supelco Equity-5, and Agilent DB-1, DB-5, DB-5ms, VF-5ms, VF-Xms and DB-XLB). Group II includes ionic liquid columns (Supelco SLB-IL61, SLB-IL111 and SLB-IL76) with very high polarity. Group III includes columns with high-percentage phenyl and cyanopropyl phases (Agilent DB-17 and DB-225, Quadrex CPS-1, Supelco SP-2331, and Agilent CP-Sil 88), and Group IV columns with shape selectivity (Dionex SB-Smectic and Restek LC-50, Supelco βDEXcst, Agilent VF-Xms and DB-XLB). Thus, two columns appeared in both Group I and IV (Agilent VF-Xms and DB-XLB). The selectivity of the other column, Agilent DB-210, differs from those of these four groups. Partial least squares (PLS) regression was used to correlate the retention times of the tetra- to hexa-CDD/Fs on the 22 stationary phases with a set of physicochemical and structural descriptors to identify parameters that significantly influence the solute-stationary phase interactions. The most influential physicochemical parameters for the interaction were associated with molecular size (as reflects in the total energy, electron energy, core-core repulsion and standard entropy), solubility (aqueous solubility and n-octanol/water partition coefficient), charge distribution (molecular polarizability and dipolar moment), and reactivity (relative Gibbs free energy); and the most influential structural descriptors were related to these parameters, in particular, size and

  18. Hydrodynamic chromatography of polystyrene microparticles in micropillar array columns

    NARCIS (Netherlands)

    Op de Beeck, Jeff; de Malsche, Wim; Vangelooven, Joris; Gardeniers, Johannes G.E.; Desmet, Gert

    2010-01-01

    We report on the possibility to perform HDC in micropillar array columns and the potential advantages of such a system. The HDC performance of a pillar array column with pillar diameter = 5 μm and an interpillar distance of 2.5 μm has been characterized using both a low MW tracer (FITC) and

  19. Characterization of retentivity of reversed phase liquid chromatography columns.

    Science.gov (United States)

    Ying, P T; Dorsey, J G

    1991-03-01

    There are dozens of commercially available reversed phase columns, most marketed as C-8 or C-18 materials, but with no useful way of classifying their retentivity. A useful way of ranking these columns in terms of column "strength" or retentivity is presented. The method utilizes a value for ln k'(w), the estimated retention of a solute from a mobile phase of 100% water, and the slope of the plot of ln k' vsE(T)(30), the solvent polarity. The method is validated with 26 solutes varying in ln k'(w) from about 2 to over 20, on 14 different reversed phase columns. In agreement with previous work, it is found that the phase volume ratio of the column is the most important parameter in determining retentivity. It is strongly suggested that manufacturers adopt a uniform method of calculating this value and that it be made available in advertising, rather than the uninterpretable "% carbon".

  20. An efficient hydrophilic interaction liquid chromatography separation of 7 phospholipid classes based on a diol column

    NARCIS (Netherlands)

    Zhu, C.; Dane, A.; Spijksma, G.; Wang, M.; Greef, J. van der; Luo, G.; Hankemeier, T.; Vreeken, R.J.

    2012-01-01

    A hydrophilic interaction liquid chromatography (HILIC) - ion trap mass spectrometry method was developed for separation of a wide range of phospholipids. A diol column which is often used with normal phase chromatography was adapted to separate different phospholipid classes in HILIC mode using a

  1. Surface-enhanced resonance Raman spectroscopy as an identification tool in column liquid chromatography

    NARCIS (Netherlands)

    Seifar, R.M.; Altelaar, M.A.F.; Dijkstra, R.J.; Ariese, F.; Brinkman, U.A.T.; Gooijer, C.

    2000-01-01

    The compatibility of ion-pair reversed-phase column liquid chromatography and surface-enhanced resonance Raman spectroscopy (SERRS) for separation and identification of anionic dyes has been investigated, with emphasis on the at-line coupling via a thin-layer chromatography (TLC) plate. SERR spectra

  2. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    Energy Technology Data Exchange (ETDEWEB)

    Zacharis, Constantinos K., E-mail: zacharis@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece); Department of Food Technology, School of Food Technology and Nutrition, Alexander Technological Educational Institute (ATEI) of Thessaloniki, 57400 Thessaloniki (Greece); Tzanavaras, Paraskevas D., E-mail: ptzanava@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotelian University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2013-10-10

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables.

  3. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: A review on instrumentation and chemistries

    International Nuclear Information System (INIS)

    Zacharis, Constantinos K.; Tzanavaras, Paraskevas D.

    2013-01-01

    Graphical abstract: -- Highlights: •Review on liquid chromatography coupled to post-column derivatization. •Overview of instrumentation for post-column derivatization. •Post-column chemistries for analysis of organic compounds. -- Abstract: Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular “chemistries” that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables

  4. Use of laminar chromatographic methods for determination of separation conditions in column extraction chromatography

    International Nuclear Information System (INIS)

    Ghersini, G.; Cerrai, E.

    1978-01-01

    Possibilities of using laminar chromatographic methods (paper and thin-layer chromatography) to determine optimal separation conditions in column extraction chromatography are analysed. Most of the given laminar methods are presented as Rf-spectra, i.e. as dependences of Rf found experimentally on eluating solution component concentration. Interrelation between Rf and distribution coefficients of corresponding liquid extraction systems and retention volumes of chromatographic columns is considered. Literature data on extraction paper and thin-layer chromatography of elements with various immovable phases are presented

  5. Receptor-ligand interactions measured by an improved spun column chromatography technique. A high efficiency and high throughput size separation method

    DEFF Research Database (Denmark)

    Buus, S; Stryhn, A; Kirkby, N

    1995-01-01

    Size exclusion chromatography may under the right circumstances be an easy and powerful way to measure in solution the interaction between a receptor an dits ligand. Spun column chromatography is a fast size exclusion technique of increasing popularity, however, little information exists on the m......Size exclusion chromatography may under the right circumstances be an easy and powerful way to measure in solution the interaction between a receptor an dits ligand. Spun column chromatography is a fast size exclusion technique of increasing popularity, however, little information exists...... on the method development essential to obtain efficient separation in particular when used for analytical purposes. In this paper we describe a systematic approach to select the optimal parameters for spun column separation including a simple modification of the technique whereby the spun columns are eluted...

  6. Resistive mode in rotating plasma columns including the hall current

    International Nuclear Information System (INIS)

    Galvao, R.M.O.

    1983-01-01

    A new resistive mode is shown to exist in rotating plasma columns. The mode is localized in the neighbourhood of the radius where the angular velocity of the bulk plasma is equal to minus half the local angular velocity of the ions. This singular point is caused by the Hall term in the generalized Ohm law. The growth rate of the mode scales with eta sup(1/2), where eta is the plasma resistivity. (Author) [pt

  7. How to select equivalent and complimentary reversed phase liquid chromatography columns from column characterization databases.

    Science.gov (United States)

    Borges, Endler M

    2014-01-07

    Three RP-LC column characterization protocols [Tanaka et al. (1989), Snyder et al. (PQRI, 2002), and NIST SRM 870 (2000)] were evaluated using both Euclidian distance and Principal Components Analysis to evaluate effectiveness at identifying equivalent columns. These databases utilize specific chromatographic properties such as hydrophobicity, hydrogen bonding, shape/steric selectivity, and ion exchange capacity of stationary phases. The chromatographic parameters of each test were shown to be uncorrelated. Despite this, the three protocols were equally successful in identifying similar and/or dissimilar stationary phases. The veracity of the results has been supported by some real life pharmaceutical separations. The use of Principal Component Analysis to identify similar/dissimilar phases appears to have some limitations in terms of loss of information. In contrast, the use of Euclidian distances is a much more convenient and reliable approach. The use of auto scaled data is favoured over the use of weighted factors as the former data transformation is less affected by the addition or removal of columns from the database. The use of these free databases and their corresponding software tools shown to be valid for identifying similar columns with equivalent chromatographic selectivity and retention as a "backup column". In addition, dissimilar columns with complimentary chromatographic selectivity can be identified for method development screening strategies. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. High-throughput liquid chromatography for drug analysis in biological fluids: investigation of extraction column life.

    Science.gov (United States)

    Zeng, Wei; Fisher, Alison L; Musson, Donald G; Wang, Amy Qiu

    2004-07-05

    A novel method was developed and assessed to extend the lifetime of extraction columns of high-throughput liquid chromatography (HTLC) for bioanalysis of human plasma samples. In this method, a 15% acetic acid solution and 90% THF were respectively used as mobile phases to clean up the proteins in human plasma samples and residual lipids from the extraction and analytical columns. The 15% acetic acid solution weakens the interactions between proteins and the stationary phase of the extraction column and increases the protein solubility in the mobile phase. The 90% THF mobile phase prevents the accumulation of lipids and thus reduces the potential damage on the columns. Using this novel method, the extraction column lifetime has been extended to about 2000 direct plasma injections, and this is the first time that high concentration acetic acid and THF are used in HTLC for on-line cleanup and extraction column lifetime extension.

  9. Improved Reversed Phase Chromatography of Hydrophilic Peptides from Spatial and Temporal Changes in Column Temperature

    DEFF Research Database (Denmark)

    Young, Clifford; Podtelejnikov, Alexandre V; Nielsen, Michael Lund

    2017-01-01

    Reversed phase chromatography is an established method for peptide separation and frequently coupled to electrospray ionization-mass spectrometry for proteomic analysis. Column temperature is one parameter that influences peptide retention and elution, but it is often overlooked as its implementa...... version when the analytical column temperature was decreased to 5 °C. Aside from demonstrating the utility of lower temperatures for improved chromatography, its application at specific locations and time points is critical for peptide detection and separation.......Reversed phase chromatography is an established method for peptide separation and frequently coupled to electrospray ionization-mass spectrometry for proteomic analysis. Column temperature is one parameter that influences peptide retention and elution, but it is often overlooked as its...

  10. Adiabatic packed column supercritical fluid chromatography using a dual-zone still-air column heater.

    Science.gov (United States)

    Helmueller, Shawn C; Poe, Donald P; Kaczmarski, Krzysztof

    2018-02-02

    An approach to conducting SFC separations under pseudo-adiabatic condition utilizing a dual-zone column heater is described. The heater allows for efficient separations at low pressures above the critical temperature by imposing a temperature profile along the column wall that closely matches that for isenthalpic expansion of the fluid inside the column. As a result, the efficiency loss associated with the formation of radial temperature gradients in this difficult region can be largely avoided in packed analytical scale columns. For elution of n-octadecylbenzene at 60 °C with 5% methanol modifier and a flow rate of 3 mL/min, a 250 × 4.6-mm column packed with 5-micron Kinetex C18 particles began to lose efficiency (8% decrease in the number of theoretical plates) at outlet pressures below 142 bar in a traditional forced air oven. The corresponding outlet pressure for onset of excess efficiency loss was decreased to 121 bar when the column was operated in a commercial HPLC column heater, and to 104 bar in the new dual-zone heater operated in adiabatic mode, with corresponding increases in the retention factor for n-octadecylbenzene from 2.9 to 6.8 and 14, respectively. This approach allows for increased retention and efficient separations of otherwise weakly retained analytes. Applications are described for rapid SFC separation of an alkylbenzene mixture using a pressure ramp, and isobaric separation of a cannabinoid mixture. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Seismic behavior of circular reinforced concrete bridge columns under combined loading including torsion.

    Science.gov (United States)

    2009-12-01

    Reinforced concrete (RC) columns of skewed and curved bridges with unequal spans and column heights can be subjected to : combined loading including axial, flexure, shear, and torsion loads during earthquakes. The combination of axial loads, shear : ...

  12. Twin-column CaptureSMB: a novel cyclic process for protein A affinity chromatography.

    Science.gov (United States)

    Angarita, Monica; Müller-Späth, Thomas; Baur, Daniel; Lievrouw, Roel; Lissens, Geert; Morbidelli, Massimo

    2015-04-10

    A twin-column counter-current chromatography processes, CaptureSMB, was used for the protein A affinity capture of a monoclonal antibody (mAb). By means of sequential loading, the process improves the utilization of the stationary phase by achieving loadings much closer to the static binding capacity of the resin in comparison to batch chromatography. Using a mAb capture case study with protein A affinity chromatography, the performance and product quality obtained from CaptureSMB and batch processes were compared. The effect of the flow rate, column length and titer concentration on the process performance and product quality were evaluated. CaptureSMB showed superior performance compared to batch chromatography with respect to productivity, capacity utilization, product concentration and buffer consumption. A simplified economic evaluation showed that CaptureSMB could decrease resin costs of 10-30% depending on the manufacturing scenario. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Single-column ion chromatography with determination of hydrazoic acid produced in spent nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Ma Guilan; Tan Shuping

    2006-01-01

    The reaction of hydrazine and its derivative with ammonium metavanadate may produce hydrazoic acid (HN 3 ). A single-column ion chromatography is used for the determination of HN 3 after neutralizing the rest acid in the sample with sodium hydroxide. Chromatography separation of HN 3 is carried out on a 25 cm x 0.46 cm (inside diameter) stainless steel column packed with Vydac IC302 ion Chromatography packing. The eluent is 1 mmol/L o-phthalic acid, and the ion is detected by conductivity detector. The detection limit in the presence chromatography is 5 μg/mL, the linear range is from 5 to 201 μg/mL, the linear correlation coefficient is 0.9994, respectively. The analysis accuracy is 2% for standard sample, and the detection limit is 51 μg/mL for HN 3 in the real sample. (authors)

  14. Phytochemical analysis of ethanolic extract of Dichrostachys Cinerea W and Arn leaves by a thin layer chromatography, high performance thin layer chromatography and column chromatography

    Directory of Open Access Journals (Sweden)

    M Vijayalakshmi

    2013-01-01

    Full Text Available Background: The leaves of Dichrostachys cinerea are used as laxative, diuretic, painkiller. It is also used in the treatment of gonorrhoea, boils, oedema, gout, veneral diseases and nasopharyngeal affections, etc. Materials and Methods: The Phytochemical investigation of ethanolic extract of D. cinerea leaves were performed by standard chemical tests, thin layer chromatography (TLC by using various solvent systems, and by high performance liquid chromatography (HPTLC. Two compounds were isolated by column chromatography and one of the compounds was identified by various spectral studies. Result : Preliminary phytochemical screening of ethanolic extract of D. cinerea leaves showed the presence of Carbohydrates, proteins, Glycosides, Saponins, Tannins, Aminoacids and Terpenoids. The TLC and HPTLC fingerprint of ethanolic extract were studied and various fractions were isolated by column chromatography and one of the fraction contain β-amyrin glucoside which was confirmed by Infra Red[IR] Spectroscopy, 1 H-Nuclear Magnetic Resonance (NMR, C- 13 NMR and Mass spectroscopic (MS studies.

  15. [Preparation of divinylbenzene polymer monolithic columns and their applications in gas chromatography].

    Science.gov (United States)

    Tian, Hongxu; Li, Yun; Chen, Jiping

    2010-11-01

    The preparation of divinylbenzene polymer monolithic columns and their applications in gas chromatography (GC) are discussed. Based on liquid chromatographic (LC) monolithic columns, the high-permeable monolithic columns can be applied in GC through changing the ratio of toluene and dodecanol. It is shown that the monolithic columns possess fastness configuration and good mechanical intensity via the bonding of 3-(trimethoxysilyl) propyl methacrylate (TMP) to the capillary wall and the polymerization of the crosslinker itself. Compared with a commercial porous layer open tube (PLOT) column and a PEG-20M column, the monolithic columns demonstrate good performance in the analysis of low carbon alcohols in water, the analysis of mixed solvents and the standard liquor sample. In the mixed solvents, the peak symmetries of alcohols, ketones, esters and aromatics precede those on the PLOT column. The separation of methanol, acetaldehyde and ethyl acetate in the standard liquor sample on the monolithic column is much more convenient than that on PEG-20M columns.

  16. A hybrid FIA/HPLC system incorporating monolithic column chromatography

    International Nuclear Information System (INIS)

    Adcock, Jacqui L.; Francis, Paul S.; Agg, Kent M.; Marshall, Graham D.; Barnett, Neil W.

    2007-01-01

    We have combined the generation of solvent gradients using milliGAT pumps, chromatographic separations with monolithic columns and chemiluminescence detection in an instrument manifold that approaches the automation and separation efficiency of HPLC, whilst maintaining the positive attributes of flow injection analysis (FIA), such as manifold versatility, speed of analysis and portability. As preliminary demonstrations of this hybrid FIA/HPLC system, we have determined six opiate alkaloids (morphine, pseudomorphine, codeine, oripavine, ethylmorphine and thebaine) and four biogenic amines (vanilmandelic acid, serotonin, 5-hydroxyindole-3-acetic acid and homovanillic acid) in human urine, using tris(2,2'-bipyridyl)ruthenium(III) and acidic potassium permanganate chemiluminescence detection

  17. Preparation of phenylboronic acid-silica hybrid monolithic column with one-pot approach for capillary liquid chromatography of biomolecules.

    Science.gov (United States)

    Lin, Zian; Huang, Hui; Li, Shihua; Wang, Juan; Tan, Xiaoqing; Zhang, Lan; Chen, Guonan

    2013-01-04

    A phenylboronic acid-silica hybrid monolithic column for capillary liquid chromatography (cLC) was prepared through one-pot process by using 4-vinylphenylboronic acid (VPBA) and alkoxysilanes simultaneously. The effects of the molar ratio of tetramethyloxysilane/γ-methacryloxypropyltrimethoxysilane (TMOS/γ-MAPS), amount of VPBA, and the volume of diethylene glycol (DEG) on the morphologies, permeabilities and pore properties of the prepared VPBA-silica hybrid monolithic columns were studied in detail. A relatively uniform monolithic structure with high porosity was obtained with optimized ingredients. A series of cis-diol-containing compounds, alkylbenzenes, amides, and anilines were utilized to evaluate the retention behaviors of the VPBA-silica hybrid monolithic column. The result demonstrated that the prepared VPBA-silica hybrid monolithic column exhibited multiple interactions including hydrophobicity, hydrophilicity, as well as cation exchange apart from the expected affinity interaction. The run-to-run, column-to-column and batch-to-batch reproducibility of the VPBA-silica hybrid monolith were satisfactory with the relative standard deviations (RSDs) less than 1.63% (n=5), 2.02% (n=3) and 2.90% (n=5), respectively, indicating the effectiveness and practicability of the proposed method. In addition, the VPBA-silica hybrid monolithic column was further applied to the separation of proteins and tryptic digest of bovine serum albumin (BSA), respectively. The successful applications suggested the potential of the VPBA-silica hybrid monolith in proteome analysis. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Sub-to super-ambient temperature programmable microfabricated gas chromatography column

    Science.gov (United States)

    Robinson, Alex L.; Anderson, Lawrence F.

    2004-03-16

    A sub- to super-ambient temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by combining a thermoelectric cooler and temperature sensing on the microfabricated column. Sub-ambient temperature programming enables the efficient separation of volatile organic compounds and super-ambient temperature programming enables the elution of less volatile analytes within a reasonable time. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  19. Purification of antibody against Ara h 2 by a homemade immunoaffinity chromatography column.

    Science.gov (United States)

    Wu, Zhihua; Li, Kun; Zhan, Shaode; Tong, Ping; Li, Xin; Yang, Anshu; Chen, Hongbing

    2017-09-14

    Antibodies are used extensively in numerous applications both in vivo and in vitro. To purify anti-Ara h 2 polyclonal antibody, a homemade immunoaffinity chromatography (IAC) column method was established. The properties of homemade column were compared with those of the mAb affinity protein G (MPG) agarose high flow, a commercially available column successfully used in capturing polyclonal antibodies. During antibody purification from rabbits' antiserum against Ara h 2, the column capacity, recovery, and purification factor were characterized for IAC and MPG. The homemade IAC could separate the corresponding antibody with higher specificity and lower cost but with lower recovery and column capacity than those of MPG. Thus, the homemade IAC is a specific, inexpensive, and suitable method that can be used for various laboratory purifications.

  20. Carrier effect on separation efficiency of the column in reversed-phase partition chromatography

    International Nuclear Information System (INIS)

    Pszonicka, M.; Siekierski, S.

    1972-01-01

    Chromatographic columns were filled with carriers of diatomaceous earth type (Hyflo Super Cell, and Celite 545) of large pores, and two microporous silica gels respectively. These columns were used for the separation of europium and gadolinium by reversed-phase partition chromatography in the system: stationary phase-diethylhexylphosphoric acid (HDEHP) mobile phase-0.4 N nitric acid. In each case the separation of the above mentioned elements was achieved. The plate height that characterizes separation efficiency of the column, decreases with the decrease of particle diameter of the carrier. Best columns were obtained from carriers of large pores (Hyflo Super Cell and Celite 545) for which plate hights below 0.1 mm could be achieved. Columns filled with microporous silica gels showed plate heights of 0.2-0.3 mm. (author)

  1. Selective isolation of β-glucan from corn pericarp hemicelluloses by affinity chromatography on cellulose column.

    OpenAIRE

    Yoshida, Tomoki; Honda, Yoichi; Tsujimoto, Takashi; Uyama, Hiroshi; Azuma, Jun-ichi

    2014-01-01

    A combination of anion-exchange chromatography and affinity chromatography on a cellulose column was found to be effective for the isolation of β-(1, 3;1, 4)-glucan (BG) from corn pericarp hemicelluloses (CPHs). CPHs containing 6.6% BG were extracted from corn pericarp with 6M urea-2 wt% NaOH solution and initially fractionated into neutral and acidic parts by anion exchange chromatography to remove acidic arabinoxylan consisting of arabinose (35.6%) and xylose (50.9%). The neutral fraction (...

  2. Determination of betaine, l-carnitine, and choline in human urine using a self-packed column and column-switching ion chromatography with nonsuppressed conductivity detection.

    Science.gov (United States)

    Wei, Dan; Liu, Junwei; Guo, Ming; Zhu, Yan

    2017-11-01

    A simple method for the determination of betaine, l-carnitine, and choline in human urine was developed based on column-switching ion chromatography coupled with nonsuppressed conductivity detection by using a self-packed column. A pretreatment column (50 mm × 4.6 mm, id) packed with poly(glycidyl methacrylate-divinylbenzene) microspheres was used for the extraction and cleanup of analytes. Chromatographic separation was achieved within 10 min on a cationic exchange column (150 mm × 4.6 mm, id) using maleic anhydride modified poly(glycidyl methacrylate-divinylbenzene) as the particles for packing. The detection was performed by ion chromatography with nonsuppressed conductivity detection. Parameters including column-switching time, eluent type, flow rates of eluent, and interfering effects were optimized. Linearity (r 2 ≥ 0.99) was obtained for the concentration range of 0.50-100, 0.75-100, and 0.25-100 μg/mL for betaine, l-carnitine, and choline, respectively. Detection limits were 0.12, 0.20, and 0.05 μg/mL for betaine, l-carnitine, and choline, respectively. The intra- and interday accuracy and precision for all quality controls were within ±10.11%. Satisfactory recovery was observed between 92.5 and 105.0%. The validated method was successfully applied for the determination of betaine, l-carnitine, and choline in urine samples from healthy people. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Phase Equilibrium and Diffusion of Solvents in Polybutadiene: A Capillary-Column Inverse Gas Chromatography Study

    NARCIS (Netherlands)

    Cai, W.D.; Ramesh, N.; Tihminlioglu, F.; Danner, R.P.; Duda, J.L.; de Haan, A.B.

    2002-01-01

    The capillary-column inverse gas chromatography method was used to measure the diffusion and partition coefficients of ethylbenzene, styrene, and acrylonitrile in polybutadiene (PBD) at infinite dilution of the solvents. Experiments were performed over a temperature range of 50-125 °C. At

  4. Separation of the Carotenoid Bixin from Annatto Seeds Using Thin-Layer and Column Chromatography

    Science.gov (United States)

    McCullagh, James V.; Ramos, Nicholas

    2008-01-01

    In this experiment the carotenoid bixin is isolated from annatto ("Bixa orellana") seeds using column chromatography. The experiment has several key advantages over previous pigment separation experiments. First, unlike other experiments significant quantities of the carotenoid (typically 20 to 25 mg) can be isolated from small quantities of plant…

  5. Novel approach to determine ghrelin analogs by liquid chromatography with mass spectrometry using a monolithic column

    Czech Academy of Sciences Publication Activity Database

    Zemenová, Jana; Sýkora, D.; Adámková, H.; Maletínská, Lenka; Elbert, Tomáš; Marek, Aleš; Blechová, Miroslava

    2017-01-01

    Roč. 40, č. 5 (2017), s. 1032-1039 ISSN 1615-9306 Institutional support: RVO:61388963 Keywords : enzyme-linked immunosorbent assay * ghrelin * lipopeptides * liquid chromatography mass spectrometry * monolithic columns Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 2.557, year: 2016

  6. Mechanized sephadex LH-20 multiple column chromatography as a prerequisite to automated multi-steroid radioimmunoassays

    International Nuclear Information System (INIS)

    Sippell, W.G.; Bidlingmaier, F.; Knorr, D.

    1977-01-01

    In order to establish a procedure for the simultaneous determination of all major corticosteroid hormones and their immediate biological precursors in the same plasma sample, two different mechanized methods for the simultaneous isolation of aldosterone (A), corticosterone (B), 11-deoxycorticosterone (DOC), progesterone (P), 17-hydroxyprogesterone (17-OHP), 11-deoxycorticol (S), cortisol (F), and cortisone (E) from the methylene chloride extracts of 0.1 to 2.0 ml plasma samples have been developed. In both methods, eluate fractions of each of the isolated steroids are automatically pooled and collected from all parallel columns by one programmable linear fraction collector. Due to the high reproducibility of the elution patterns both between different parallel columns and between 30 to 40 consecutive elutions, mean recoveries of tritiated steroids including extraction are 60 to 84% after a single elution and still over 50% after an additional chromatography on 40cm LH-20 colums, with coefficients of variation below 15%. Thus, the eight steroids can be completely isolated from each of ten plasma extracts within 3 to 4 hours, yielding 80 samples readily prepared for subsequent quantitation by radioimmunoassay. (orig./AJ) [de

  7. Coupling of column liquid chromatography and surface-enhanced resonance Raman spectroscopy via a thin-layer chromatographic plate.

    NARCIS (Netherlands)

    Coulter, S.K.; Gooijer, C.; Velthorst, N.H.; Brinkman, U.A.T.; Somsen, G.W.

    1997-01-01

    Surface-enhanced resonance Raman (SERR) spectroscopy was used to characterize compounds separated by column liquid chromatography (LC). Three percent of the effluent from a conventional-size LC column were immobilized on a moving thinlayer chromatography (TLC) plate using a spray-jet

  8. Preparative separation of polyphenols from artichoke by polyamide column chromatography and high-speed counter-current chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Xikai; Wang, Mei; Liu, Daicheng [College of Life Science, Shandong Normal University, Jinan, Shandong (China); Wang, Daijie; Lin, Xiaojing; Liu, Jianhua; Wang, Xiao; Huang, Luqi, E-mail: wxjn1998@126.com [Shandong Analysis and Test Center, Shandong Academy of Sciences, Jinan, Shandong (China)

    2013-09-01

    An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-{beta}-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-{beta}-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR). (author)

  9. Preparative separation of polyphenols from artichoke by polyamide column chromatography and high-speed counter-current chromatography

    Directory of Open Access Journals (Sweden)

    Xikai Shu

    2013-01-01

    Full Text Available An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I, 24.5 mg of luteolin-7-O-β-D-rutinoside (compound II, 18.4 mg of luteolin-7-O-β-D-glucoside (compound III, and 33.4 mg of cynarin (compound IV with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS and nuclear magnetic resonance (NMR.

  10. 5-O-caffeoylshikimic acid from Solanum somalense leaves: advantage of centrifugal partition chromatography over conventional column chromatography.

    Science.gov (United States)

    Chideh, Saïda; Pilard, Serge; Attoumbré, Jacques; Saguez, Robert; Hassan-Abdallah, Alshaimaa; Cailleu, Dominique; Wadouachi, Anne; Baltora-Rosset, Sylvie

    2014-09-01

    Solanum somalense leaves, used in Djibouti for their medicinal properties, were extracted by MeOH. Because of the high polyphenol and flavonoid contents of the extract, respectively, determined at 80.80 ± 2.13 mg gallic acid equivalent/g dry weight and 24.4 ± 1.01 mg quercetin equivalent/g dry weight, the isolation and purification of the main polyphenols were carried out by silica gel column chromatography and centrifugal partition chromatography. Column chromatography led to 11 enriched fractions requiring further purification, while centrifugal partition chromatography allowed the easy recovery of the main compound of the extract. In a solvent system composed of CHCl3/MeOH/H2O (9.5:10:5), 21.8 mg of this compound at 97% purity was obtained leading to a yield of 2.63%. Its structure was established as 5-O-caffeoylshikimic acid by mass spectrometry and NMR spectroscopy. This work shows that S. somalense leaves contain very high level of 5-O-caffeoylshikimic acid (0.74% dry weight), making it a potential source of production of this secondary metabolite that is not commonly found in nature but could be partly responsible of the medicinal properties of S. somalense leaves. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Taming axial dispersion in hydrodynamic chromatography columns through wall patterning

    Science.gov (United States)

    Adrover, Alessandra; Cerbelli, Stefano; Giona, Massimiliano

    2018-04-01

    A well-known limitation of hydrodynamic chromatography arises from the synergistic interaction between transverse diffusion and streamwise convection, which enhances axial dispersion through the Taylor-Aris mechanism. We show that a periodic sequence of slip/no-slip conditions at the channel walls (e.g., representing wall indentations hosting stable air pockets) can significantly reduce axial dispersion, thus enhancing separation performance. The theoretical/numerical analysis is based on a generalization of Brenner's macrotransport approach to solute transport, here modified to account for the finite-size of the suspended particles. The most effective dispersion-taming outcome is observed when the alternating sequence of slip/no-slip conditions yields non-vanishing cross-sectional flow components. The combination of these components with the hindering interaction between the channel boundaries and the finite-sized particles gives rise to a non-trivial solution of Brenner's problem on the unit periodic cell, where the cross-sectional particle number density departs from the spatially homogeneous condition. In turn, this effect impacts upon the solution of the so-called b-field defining the large-scale dispersion tensor, with an overall decremental effect on the axial dispersion coefficient and on the Height Equivalent of a Theoretical Plate.

  12. Behavior of macroporous vinyl silica and silica monolithic columns in high pressure gas chromatography.

    Science.gov (United States)

    Maniquet, Adrien; Bruyer, Nicolas; Raffin, Guy; Baco-Antionali, Franck; Demesmay, Claire; Dugas, Vincent; Randon, Jérôme

    2017-06-30

    80% vinyltrimethoxysilane-based hybrid silica monoliths (80-VTMS), which have been initially developed for separation in reversed-phase liquid chromatography, have been investigated in high pressure gas chromatography separations (carrier gas pressure up to 60bar) and compared to silica monolithic columns. The behavior of both silica and 80-VTMS monolithic columns was investigated using helium, nitrogen and carbon dioxide as carrier gas. The efficiency of 80-VTMS monolithic columns was shown to vary differently than silica monolithic columns according to the temperature and the carrier gas used. Carrier gas nature was a significant parameter on the retention for both silica and vinyl columns in relation to its adsorption onto the stationary phase in such high pressure conditions. The comparison of retention and selectivity between 80-VTMS monoliths and silica was performed under helium using the logarithm of the retention factor according to the number of carbon atoms combined to Kovats indexes. The very good performances of these columns were demonstrated, allowing the separation of 8 compounds in less than 1min. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Quantification of PSP toxins in toxic shellfish matrices using post-column oxidation liquid chromatography and pre-column oxidation liquid chromatography methods suggests post-column oxidation liquid chromatography as a good monitoring method of choice.

    Science.gov (United States)

    Rey, Verónica; Botana, Ana M; Botana, Luis M

    2017-04-01

    Different shellfish samples were analyzed by Pre- and Post-Column Oxidation Liquid Chromatography to compare the toxins profiles and get information about the degree of accomplishment of both methods. Comparison of the results obtained, the linear correlation coefficient (r 2  = 0.94) and the paired t test (two tails, α = 0.05), indicated that there were not significant differences between both sets of data. Nevertheless, important differences related to toxins profiles were found: it was remarkable the difference in results for both Gonyautoxins 1 and 4 and Decarbamoylgonyautoxins 2 and 3, depending on the method of choice, due to an overestimation in the Pre-Column method. It was necessary to modify the elution conditions in the Post-Column method to avoid the interference of matrix peaks at retention times closer to the retention times of the calibrants, mostly when working with oyster and scallop matrices, although it is a good method to use routinely. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. The art and science of forming packed analytical high-performance liquid chromatography columns.

    Science.gov (United States)

    Kirkland, J J; Destefano, J J

    2006-09-08

    Columns of packed particles still are the most popular devices for high-performance liquid chromatography (HPLC) separations because of their great utility, excellent performance and wide variety. However, the forming of packed beds for efficient, stable columns traditionally has been an art where the basics of how to form optimum beds generally was not well understood. The recent development of monolith rods was introduced in part to overcome the difficulty of producing stable beds of packing particles. However, these materials are less versatile than packed particle columns. Technology developments in recent years have produced a better understanding among those skilled in the practice of how to form optimized packed beds, and this has led to widely available, high-quality commercial columns. This presentation discusses the developments that led to the present state of column packing technology. Important steps in the packing of efficient, stable beds are described. The key step of selecting the best solvent for the slurry packing method is emphasized. Factors affecting the mechanical stability of packed columns also are discussed. The early art of packing columns now has evolved into a more scientific approach that allows the packing of good columns with a minimum of effort and time.

  15. Regenerated silica gel as stationary phase on vacuum column chromatography to purify temulawak's extracts

    Science.gov (United States)

    Cahyono, Bambang; Maduwu, Ratna Dewi; Widayat, Suzery, Meiny

    2015-12-01

    Commercial silica gel only used once by many researchers and affected high cost for purification process, also less support the green chemistry program. This research focused in regeneration silica gel that used purification of temulawak's extracts (Curcuma xanthorrhiza Roxb) by vacuum column chromatography. Sample extracts (contains 10.1195±0.5971% of curcuminoids) was purified by vacuum column chromatography (pressure: 45 kPa, column: 100mm on length and 16mm on diameter). Ethanol 96% and acetone were compared as eluent. The amount of solvent and yield of curcuminoids used as indicator purification. The silica gel was regenerated with heating in 600°C for 8 hours The silica gels were analyzed by IR spectroscopy and X-ray diffraction. Furthermore, regenerated silica gel was used as the stationary phase in vacuum column chromatography under the same conditions with the previous purification. All the purification experiments were performed in three repetitions. Based on regression equation, y=0.132x+0.0011 (r2=0.9997) the yield of curcuminoids on purified products using ethanol as the eluent was improved 4.26% (to 14.3724±0.5749%) and by acetone was improved 3,03% (to 13.1450 ±0.6318%). The IR spectrum of both silica gel showed the same vibration profile and also there were three crystallinity peaks missing on its X-ray diffraction. Regenerated silica gel has the same performance with new silica gel in purification of temulawak's extract: by ethanol has increased 4.08% (14.1947±0.7415%) and 2.93% (13.0447±0.4822) by acetone. In addition, all purification products showed similar TLC profiles. Purification using regenerated silica gel as the adsorbent on vacuum column chromatography has exactly same potential with the new silica gel.

  16. Regenerated silica gel as stationary phase on vacuum column chromatography to purify temulawak’s extracts

    International Nuclear Information System (INIS)

    Cahyono, Bambang; Maduwu, Ratna Dewi; Widayat,; Suzery, Meiny

    2015-01-01

    Commercial silica gel only used once by many researchers and affected high cost for purification process, also less support the green chemistry program. This research focused in regeneration silica gel that used purification of temulawak’s extracts (Curcuma xanthorrhiza Roxb) by vacuum column chromatography. Sample extracts (contains 10.1195±0.5971% of curcuminoids) was purified by vacuum column chromatography (pressure: 45 kPa, column: 100mm on length and 16mm on diameter). Ethanol 96% and acetone were compared as eluent. The amount of solvent and yield of curcuminoids used as indicator purification. The silica gel was regenerated with heating in 600°C for 8 hours The silica gels were analyzed by IR spectroscopy and X-ray diffraction. Furthermore, regenerated silica gel was used as the stationary phase in vacuum column chromatography under the same conditions with the previous purification. All the purification experiments were performed in three repetitions. Based on regression equation, y=0.132x+0.0011 (r 2 =0.9997) the yield of curcuminoids on purified products using ethanol as the eluent was improved 4.26% (to 14.3724±0.5749%) and by acetone was improved 3,03% (to 13.1450 ±0.6318%). The IR spectrum of both silica gel showed the same vibration profile and also there were three crystallinity peaks missing on its X-ray diffraction. Regenerated silica gel has the same performance with new silica gel in purification of temulawak’s extract: by ethanol has increased 4.08% (14.1947±0.7415%) and 2.93% (13.0447±0.4822) by acetone. In addition, all purification products showed similar TLC profiles. Purification using regenerated silica gel as the adsorbent on vacuum column chromatography has exactly same potential with the new silica gel

  17. Regenerated silica gel as stationary phase on vacuum column chromatography to purify temulawak’s extracts

    Energy Technology Data Exchange (ETDEWEB)

    Cahyono, Bambang; Maduwu, Ratna Dewi; Widayat,; Suzery, Meiny [Organic Chemistry Laboratory, Departement of Chemistry, Diponegoro University Jln Prof. Soedharto SH, Tembalang, Semarang 50275, Indonesia Tel / Fax: (024) 7460058 (Indonesia)

    2015-12-29

    Commercial silica gel only used once by many researchers and affected high cost for purification process, also less support the green chemistry program. This research focused in regeneration silica gel that used purification of temulawak’s extracts (Curcuma xanthorrhiza Roxb) by vacuum column chromatography. Sample extracts (contains 10.1195±0.5971% of curcuminoids) was purified by vacuum column chromatography (pressure: 45 kPa, column: 100mm on length and 16mm on diameter). Ethanol 96% and acetone were compared as eluent. The amount of solvent and yield of curcuminoids used as indicator purification. The silica gel was regenerated with heating in 600°C for 8 hours The silica gels were analyzed by IR spectroscopy and X-ray diffraction. Furthermore, regenerated silica gel was used as the stationary phase in vacuum column chromatography under the same conditions with the previous purification. All the purification experiments were performed in three repetitions. Based on regression equation, y=0.132x+0.0011 (r{sup 2}=0.9997) the yield of curcuminoids on purified products using ethanol as the eluent was improved 4.26% (to 14.3724±0.5749%) and by acetone was improved 3,03% (to 13.1450 ±0.6318%). The IR spectrum of both silica gel showed the same vibration profile and also there were three crystallinity peaks missing on its X-ray diffraction. Regenerated silica gel has the same performance with new silica gel in purification of temulawak’s extract: by ethanol has increased 4.08% (14.1947±0.7415%) and 2.93% (13.0447±0.4822) by acetone. In addition, all purification products showed similar TLC profiles. Purification using regenerated silica gel as the adsorbent on vacuum column chromatography has exactly same potential with the new silica gel.

  18. Column chromatography as a useful step in purification of diatom pigments.

    Science.gov (United States)

    Tokarek, Wiktor; Listwan, Stanisław; Pagacz, Joanna; Leśniak, Piotr; Latowski, Dariusz

    2016-01-01

    Fucoxanthin, diadinoxanthin and diatoxanthin are carotenoids found in brown algae and most other heterokonts. These pigments are involved in photosynthetic and photoprotective reactions, and they have many potential health benefits. They can be extracted from diatom Phaeodactylum tricornutum by sonication, extraction with chloroform : methanol and preparative thin layer chromatography. We assessed the utility of an additional column chromatography step in purification of these pigments. This novel addition to the isolation protocol increased the purity of fucoxanthin and allowed for concentration of diadinoxanthin and diatoxanthin before HPLC separation. The enhanced protocol is useful for obtaining high purity pigments for biochemical studies.

  19. [Preparative separation of aloin diastereoisomers by high-speed countercurrent chromatography combined with silica gel column chromatography].

    Science.gov (United States)

    Huang, Danfeng; Cao, Xueli; Zhao, Hua; Dong, Yinmao

    2006-01-01

    Aloin, naturally a mixture of two diastereoisomers, aloin A and aloin B, is the major anthraquinone in aloe, and now served as one of the important control constituents in most of the commercial aloe products. High-speed countercurrent chromatography (HSCCC) combined with silica gel column chromatography was developed for the preparative separation of the two individual aloins. Aloin A (98%) and aloin B (96%) were obtained. Fast atom bombardment mass spectrometry (FAB-MS), 1H nuclear magnetic resonance (1H NMR) and GOESY (gradient-enhanced nuclear Overhauser effect spectroscopy) were employed for the elucidation of their structure conformation. The developed method is of high preparative capacity and high efficiency in resolution.

  20. Metal-Organic Framework Thin Films as Stationary Phases in Microfabricated Gas-Chromatography Columns.

    Energy Technology Data Exchange (ETDEWEB)

    Read, Douglas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Sillerud, Colin Halliday [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    The overarching goal of this project is to integrate Sandia's microfabricated gas-chromatography ( GC) columns with a stationary phase material that is capable of retaining high-volatility chemicals and permanent gases. The successful integration of such a material with GCs would dramatically expand the repertoire of detectable compounds for Sandia's various microanalysis systems. One such promising class of candidate materials is metal-organic frameworks (MOFs). In this report we detail our methods for controlled deposition of HKUST-1 MOF stationary phases within GC columns. We demonstrate: the chromatographic separation of natural gas; a method for determining MOF film thickness from chromatography alone; and the first-reported GC x GC separation of natural gas -- in general -- let alone for two disparate MOF stationary phases. In addition we determine the fundamental thermodynamic constant for mass sorption, the partition coefficient, for HKUST-1 and several light hydrocarbons and select toxic industrial chemicals.

  1. Evaluation of phytochemical screening & extraction of lycopene from Citrullus lanatus by using column chromatography

    OpenAIRE

    lalitha govindaraj; Suseela vivek

    2015-01-01

    The present study focused on the phytochemical constituents, isolation of lycopene of the Citrullus lanatusis fruits which were collected from the local market in around sulur area, India. The phytochemical analysis of fruit extracts revealed the presence of   bioactive compounds such as phenolics, alkaloids, saponins, tannins, steroids and flavonoids in the extract. The isolation of lycopene were quantified by using column chromatography that depicted (lycopene - 68.0285 mg/k fresh wt) respe...

  2. Column chromatography with almecega resin: a project for experimental organic chemistry

    International Nuclear Information System (INIS)

    Vieira Junior, Gerardo Magela; Carvalho, Adonias Almeida; Gonzaga, Wellington de Abreu; Chaves, Mariana H.

    2007-01-01

    The use of natural products to demonstrate the silica gel column chromatography technique is proposed in the present article. It describes the separation of the triterpenes α- and β-amirin from the diol breine and maniladiol, obtained from almecega resin (Protium heptaphyllum March.). The experiment uses an accessible material, was accomplished in 4 h, and can be applied with success an the experimental course of organic chemistry for undergraduate students. (author)

  3. Flow rate dependent extra-column variance from injection in capillary liquid chromatography.

    Science.gov (United States)

    Aggarwal, Pankaj; Liu, Kun; Sharma, Sonika; Lawson, John S; Dennis Tolley, H; Lee, Milton L

    2015-02-06

    Efficiency and resolution in capillary liquid chromatography (LC) can be significantly affected by extra-column band broadening, especially for isocratic separations. This is particularly a concern in evaluating column bed structure using non-retained test compounds. The band broadening due to an injector supplied with a commercially available capillary LC system was characterized from experimental measurements. The extra-column variance from the injection valve was found to have an extra-column contribution independent of the injection volume, showing an exponential dependence on flow rate. The overall extra-column variance from the injection valve was found to vary from 34 to 23 nL. A new mathematical model was derived that explains this exponential contribution of extra-column variance on chromatographic performance. The chromatographic efficiency was compromised by ∼130% for a non-retained analyte because of injection valve dead volume. The measured chromatographic efficiency was greatly improved when a new nano-flow pumping system with integrated injection valve was used. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Selective isolation of β-glucan from corn pericarp hemicelluloses by affinity chromatography on cellulose column.

    Science.gov (United States)

    Yoshida, Tomoki; Honda, Yoichi; Tsujimoto, Takashi; Uyama, Hiroshi; Azuma, Jun-ichi

    2014-10-13

    A combination of anion-exchange chromatography and affinity chromatography on a cellulose column was found to be effective for the isolation of β-(1,3;1,4)-glucan (BG) from corn pericarp hemicelluloses (CPHs). CPHs containing 6.6% BG were extracted from corn pericarp with 6M urea-2 wt% NaOH solution and initially fractionated into neutral and acidic parts by anion exchange chromatography to remove acidic arabinoxylan consisting of arabinose (35.6%) and xylose (50.9%). The neutral fraction (yield; 10.1% on the basis of CPHs) consisting of 1.0% arabinose, 10.1% xylose and 80.3% glucose containing 28.4% BG was then applied to a cellulose column of Whatman CF-11. BG could be recovered from the adsorbed fraction on the cellulose column by elution with 2% NaOH in a yield of 2.6% on the basis of CPHs with a purity of 84.7%. The chemical structure of the isolated corn pericarp BG was confirmed by (13)C NMR spectroscopic, methylation and lichenase treatment analyses. The results indicate that the ratios of (1,4)/(1,3) linkage and cellotriosyl/cellotetraosyl segments of the BG were 2.60 and 2.5, respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Exogenous factors contributing to column bed heterogeneity: Part 1: Consequences of 'air' injections in liquid chromatography.

    Science.gov (United States)

    Samuelsson, Jörgen; Fornstedt, Torgny; Shalliker, Andrew

    2015-08-07

    It has been shown that not only the packing homogeneity, but also factors external to the column bed, such as, frits and distributors can have important effects on the column performance. This current communication is the first in a series focusing on the impact of exogenous factors on the column bed heterogeneity. This study is based on several observations by us and others that chromatographic runs often, for technical reasons, include more or less portions of air in the injections. It is therefore extremely important to find out the impact of air on the column performance, the reliability of the results derived from analyses where air was injected, and the effect on the column homogeneity. We used a photographic approach for visualising the air transport phenomena, and found that the air transport through the column is comprised of many different types of transport phenomena, such as laminal flow, viscous fingering like flows, channels and bulbs, and pulsations. More particularly, the air clouds within the column definitely interact in the adsorption, i.e. mobile phase adsorbed to the column surface is displaced. In addition, irrespective of the type of air transport phenomena, the air does not penetrate the column homogeneously. This process is strongly flow dependent. In this work we study air transport both in an analytical scale and a semi-prep column. Copyright © 2015. Published by Elsevier B.V.

  6. Preparation and application of novel zwitterionic monolithic column for hydrophilic interaction chromatography.

    Science.gov (United States)

    Liu, Zhenghua; Peng, Yongbo; Wang, Tingting; Yuan, Guangxin; Zhang, Qiaoxuan; Guo, Jialiang; Jiang, Zhengjin

    2013-01-01

    A novel zwitterionic hydrophilic porous monolithic stationary phase was prepared based on the thermal-initiated copolymerization of N,N-dimethyl-N-(3-methacryl-amidopropyl)-N-(3-(sulfopropyl)ammonium betaine and ethylene glycol dimethacrylate. A typical hydrophilic separation mechanism was observed at a highly organic mobile phase (ACN >60%) on this optimized zwitterionic hydrophilic interaction chromatography (HILIC) monolithic stationary phase. Good permeability, stability, and column efficiency were observed on the final monolithic column. Additionally, a weak electrostatic interaction for charged analytes was confirmed in analysis of six benzoic acids by studying the influence of mobile phase pH and salt concentration on their retention behaviors on the obtained zwitterionic HILIC monolithic column. The optimized zwitterionic HILIC monolith exhibited good selectivity for a range of polar test analytes. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Fabrication of electrolytic cell for online post-column electrochemical derivatization in ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Wu Shuchao [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China); Xu Wei [State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310028, Zhejiang (China); Yang Bingcheng [School of Pharmacy, East China University of Science and Technology, Shanghai 200237 (China); Ye Mingli [Thermofisher scientific (China), Shanghai 201203 (China); Zhang Peimin [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China); Shentu Chao [College of Biology and Environmental Engineering, Zhejiang Shuren University, Hangzhou 310015 (China); Zhu Yan, E-mail: zhuyan@zju.edu.cn [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China)

    2012-07-20

    Highlight: Black-Right-Pointing-Pointer An electrolytic cell including ruthenium modified titanium electrode was fabricated. Black-Right-Pointing-Pointer Ion chromatography/electrochemical derivatization/fluorescence detection was developed. Black-Right-Pointing-Pointer Strong oxidation capacity of this EC was obtained by using the Ru/Ti electrode with large surface area. - Abstract: An electrolytic cell (EC), composed of two ruthenium-plated titanium electrodes separated by cation-exchange membranes, was fabricated and evaluated for online postcolumn derivatization in ion chromatography (IC). Folic acid (FA) and methotrexate (MTX) were preliminarily used as prototype analytes to test the performance of EC. After separation by an anion exchange column, FA and MTX, which emit very weak fluorescence when excited, were electrochemically oxidized online in the anode chamber of the EC. The compounds with strong fluorescence, which are oxidation products, were detected by the fluorescence detector. The phosphate buffer solution (100 mM KH{sub 2}PO{sub 4}) served as an optimal eluent for anion exchange chromatographic separation and a suitable supporting electrolyte for electro-oxidation, leading to ideal compatibility between IC separation and the postcolumn electrochemical derivatization. For the presently proposed method, the linear ranges were from 0.01 mg L{sup -1} to 5 mg L{sup -1} for both FA and MTX. The detection limits of FA and MTX were 1.8 and 2.1 {mu}g L{sup -1}, and the relative standard deviations (RSD, n = 7) were 2.9% and 3.6%, respectively. The method was applied for the simultaneous determination of FA and MTX in the plasma of patients being treated for rheumatoid arthritis. The determination of MTX in the urine of the patients of diffuse large B cell lymphoma was also demonstrated.

  8. Column chromatography isolation of nicotine from tobacco leaf extract (Nicotiana tabaccum L.)

    Science.gov (United States)

    Fathi, Raden Muhammad; Fauzantoro, Ahmad; Rahman, Siti Fauziyah; Gozan, Misri

    2018-02-01

    Restrictions on the use of dried tobacco leaf for cigarette production must be accompanied by the development of non-cigarette alternative products that are made from tobacco leaves. One of the alternative that can be done is to use the nicotine compound in tobacco leaf extract as medical product, such as Parkinson's medication or to be used as active substance in biopesticide. Nicotine was isolated using column chromatography method with the variation of mobile phase mixture ratio (petroleum ether and ethanol), started from 8:2, 6:4, 4:6, 2:8, to 0:10. All of the chromatographic fraction from each mobile phase's ratio was then tested qualitatively using thin layer chromatography (TLC) and also quantitatively using HPLC instrument. The column chromatography process could isolate 4.006% of nicotine compound from 4.19% tobacco leaf extract's nicotine. It is also known that ethanol is a good solution to be used as chromatography's mobile phase for nicotine isolation from tobacco leaf extract.

  9. Novel design for centrifugal counter-current chromatography: VI. Ellipsoid column.

    Science.gov (United States)

    Gu, Dongyu; Yang, Yi; Xin, Xuelei; Aisa, Haji Akber; Ito, Yoichiro

    2015-01-01

    A novel ellipsoid column was designed for centrifugal counter-current chromatography. Performance of the ellipsoid column with a capacity of 3.4 mL was examined with three different solvent systems composed of 1-butanol-acetic acid-water (4:1:5, v/v) (BAW), hexane-ethyl acetate-methanol-0.1 M HCl (1:1:1:1, v/v) (HEMH), and 12.5% (w/w) PEG1000 and 12.5% (w/w) dibasic potassium phosphate in water (PEG-DPP) each with suitable test samples. In dipeptide separation with BAW system, both stationary phase retention (Sf) and peak resolution (Rs) of the ellipsoid column were much higher at 0° column angle (column axis parallel to the centrifugal force) than at 90° column angle (column axis perpendicular to the centrifugal force), where elution with the lower phase at a low flow rate produced the best separation yielding Rs at 2.02 with 27.8% Sf at a flow rate of 0.07 ml/min. In the DNP-amino acid separation with HEMW system, the best results were obtained at a flow rate of 0.05 ml/min with 31.6% Sf yielding high Rs values at 2.16 between DNP-DL-glu and DNP-β-ala peaks and 1.81 between DNP-β-ala and DNP-L-ala peaks. In protein separation with PEG-DPP system, lysozyme and myolobin were resolved at Rs of 1.08 at a flow rate of 0.03 ml/min with 38.9% Sf. Most of those Rs values exceed those obtained from the figure-8 column under similar experimental conditions previously reported.

  10. Determination of zearalenone content in cereals and feedstuffs by immunoaffinity column coupled with liquid chromatography.

    Science.gov (United States)

    Fazekas, B; Tar, A

    2001-01-01

    The zearalenone content of maize, wheat, barley, swine feed, and poultry feed samples was determined by immunoaffinity column cleanup followed by liquid chromatography (IAC-LC). Samples were extracted in methanol-water (8 + 2, v/v) solution. The filtered extract was diluted with distilled water and applied to immunoaffinity columns. Zearalenone was eluted with methanol, dried by evaporation, and dissolved in acetonitrile-water (3 + 7, v/v). Zearalenone was separated by isocratic elution of acetonitrile-water (50 + 50, v/v) on reversed-phase C18 column. The quantitative analysis was performed by fluorescence detector and confirmation was based on the UV spectrum obtained by a diode array detector. The mean recovery rate of zearalenone was 82-97% (RSD, 1.4-4.1%) on the original (single-use) immunoaffinity columns. The limit of detection of zearalenone by fluorescence was 10 ng/g at a signal-to-noise ratio of 10:1 and 30 ng/g by spectral confirmation in UV. A good correlation was found (R2 = 0.89) between the results obtained by IAC-LC and by the official AOAC-LC method. The specificity of the method was increased by using fluorescence detection in parallel with UV detection. This method was applicable to the determination of zearalenone content in cereals and other kinds of feedstuffs. Reusability of immunoaffinity columns was examined by washing with water after sample elution and allowing columns to stand for 24 h at room temperature. The zearalenone recovery rate of the regenerated columns varied between 79 and 95% (RSD, 3.2-6.3%). Columns can be regenerated at least 3 times without altering their performance and without affecting the results of repeated determinations.

  11. Ultra high pressure liquid chromatography. Column permeability and changes of the eluent properties.

    Science.gov (United States)

    Gritti, Fabrice; Guiochon, Georges

    2008-04-11

    The behavior of four similar liquid chromatography columns (2.1mm i.d. x 30, 50, 100, and 150 mm, all packed with fine particles, average d(p) approximately 1.7 microm, of bridged ethylsiloxane/silica hybrid-C(18), named BEH-C(18)) was studied in wide ranges of temperature and pressure. The pressure and the temperature dependencies of the viscosity and the density of the eluent (pure acetonitrile) along the columns were also derived, using the column permeabilities and applying the Kozeny-Carman and the heat balance equations. The heat lost through the external surface area of the chromatographic column was directly derived from the wall temperature of the stainless steel tube measured with a precision of +/-0.2 degrees C in still air and +/-0.1 degrees C in the oven compartment. The variations of the density and viscosity of pure acetonitrile as a function of the temperature and pressure was derived from empirical correlations based on precise experimental data acquired between 298 and 373 K and at pressures up to 1.5 kbar. The measurements were made with the Acquity UPLC chromatograph that can deliver a maximum flow rate of 2 mL/min and apply a maximum column inlet pressure of 1038 bar. The average Kozeny-Carman permeability constant of the columns was 144+/-3.5%. The temperature hence the viscosity and the density profiles of the eluent along the column deviate significantly from linear behavior under high-pressure gradients. For a 1000 bar pressure drop, we measured DeltaT=25-30 K, (Deltaeta/eta) approximately 100%, and (Deltarho/rho) approximately 10%. These results show that the radial temperature profiles are never fully developed within 1% for any of the columns, even under still-air conditions. This represents a practical advantage regarding the apparent column efficiency at high flow rates, since the impact of the differential analyte velocity between the column center and the column wall is not maximum. The interpretation of the peak profiles recorded in

  12. Preparation and evaluation of molecularly imprinted polymer liquid chromatography column for the separation of ephedrine enantiomers

    Directory of Open Access Journals (Sweden)

    Krishnamoorthy balamurugan

    2016-09-01

    Full Text Available In this study molecular imprinting technology was employed to prepare a specific affinity sorbent for the resolution of Ephedrine, a chiral drug. The molecularly imprinted polymer (MIP was prepared by non-covalent molecular imprinting with either (+ or (--Ephedrine ((R∗,S∗-2-(methylamino-1-phenylpropan-1-ol as the template. Methacrylic acid and ethylene glycol di-methacrylate were copolymerized in the presence of the template molecule. The bulk polymerization was carried out in chloroform with 2,2′-azobisisobutyronitrile as the initiator, at 5°C and under UV radiation. The resulting MIP was ground into powders, which were slurry packed into analytical columns. After removal of template molecules, the MIP-packed columns were found to be effective for the resolution of (±-Ephedrine racemates. The separation factor for the enantiomers ranged between 1.3 and 2.1 when the column was packed with MIP prepared with (+-Ephedrine as the template. A separation factor ranging from 1.3 to 2.6 could be achieved from the column packed with MIP, prepared with (--Ephedrine as the template. Although the separation factor was higher with that previously obtained from reversed-phase column chromatography following derivatization with a chiral agent, elution peaks were broader due to the heterogeneity of binding sites on the MIP particles and the possible non-specific interaction.

  13. In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies

    Science.gov (United States)

    Boulet-Audet, Maxime; Kazarian, Sergei G.; Byrne, Bernadette

    2016-01-01

    In recent years many monoclonal antibodies (mAb) have entered the biotherapeutics market, offering new treatments for chronic and life-threatening diseases. Protein A resin captures monoclonal antibody (mAb) effectively, but the binding capacity decays over repeated purification cycles. On an industrial scale, replacing fouled Protein A affinity chromatography resin accounts for a large proportion of the raw material cost. Cleaning-in-place (CIP) procedures were developed to extend Protein A resin lifespan, but chromatograms cannot reliably quantify any remaining contaminants over repeated cycles. To study resin fouling in situ, we coupled affinity chromatography and Fourier transform infrared (FTIR) spectroscopy for the first time, by embedding an attenuated total reflection (ATR) sensor inside a micro-scale column while measuring the UV 280 nm and conductivity. Our approach quantified the in-column protein concentration in the resin bed and determined protein conformation. Our results show that Protein A ligand leached during CIP. We also found that host cell proteins bound to the Protein A resin even more strongly than mAbs and that typical CIP conditions do not remove all fouling contaminants. The insights derived from in-column ATR-FTIR spectroscopic monitoring could contribute to mAb purification quality assurance as well as guide the development of more effective CIP conditions to optimise resin lifespan. PMID:27470880

  14. In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies

    Science.gov (United States)

    Boulet-Audet, Maxime; Kazarian, Sergei G.; Byrne, Bernadette

    2016-07-01

    In recent years many monoclonal antibodies (mAb) have entered the biotherapeutics market, offering new treatments for chronic and life-threatening diseases. Protein A resin captures monoclonal antibody (mAb) effectively, but the binding capacity decays over repeated purification cycles. On an industrial scale, replacing fouled Protein A affinity chromatography resin accounts for a large proportion of the raw material cost. Cleaning-in-place (CIP) procedures were developed to extend Protein A resin lifespan, but chromatograms cannot reliably quantify any remaining contaminants over repeated cycles. To study resin fouling in situ, we coupled affinity chromatography and Fourier transform infrared (FTIR) spectroscopy for the first time, by embedding an attenuated total reflection (ATR) sensor inside a micro-scale column while measuring the UV 280 nm and conductivity. Our approach quantified the in-column protein concentration in the resin bed and determined protein conformation. Our results show that Protein A ligand leached during CIP. We also found that host cell proteins bound to the Protein A resin even more strongly than mAbs and that typical CIP conditions do not remove all fouling contaminants. The insights derived from in-column ATR-FTIR spectroscopic monitoring could contribute to mAb purification quality assurance as well as guide the development of more effective CIP conditions to optimise resin lifespan.

  15. Analysis of underivatised low volatility compounds by comprehensive two-dimensional gas chromatography with a short primary column.

    Science.gov (United States)

    Novaes, Fábio Junior Moreira; Kulsing, Chadin; Bizzo, Humberto Ribeiro; de Aquino Neto, Francisco Radler; Rezende, Claudia Moraes; Marriott, Philip John

    2018-02-09

    Comprehensive two-dimensional gas chromatography (GC×GC) approaches with cryogenic modulation were developed for the qualitative analysis of selected low volatility compounds in raw coffee bean extracts, without derivatisation. The approaches employed short first ( 1 D) and second ( 2 D) dimension columns, specifically a 1 D 65% phenyl methyl siloxane column (11m) and a 2 D 5% phenyl methyl siloxane column (1m), which allowed elution of high molar mass compounds (e.g.>600Da). Solutes included hydrocarbons, fatty acids, diterpenes, tocopherols, sterols, diterpene esters, and di- and triacylglycerides. An oven temperature program up to 370°C was employed. The effects of experimental conditions were investigated, revealing that the GC×GC results strongly depended on the cryogenic trap T, and oven T program. An appropriate condition was selected and further applied for group type analysis of low volatility compounds in green Arabica coffee beans. Retention indices were compiled for 1D GC analysis and were similar for the composite column data in GC×GC. The elution of some compounds was confirmed by use of authentic standards. The approach allowed direct analysis of coffee extract in ethyl acetate solution, with improved analyte peak capacity (approximately 200 compounds were detected) without prior fractionation or pre-treatment of the sample. This avoided potential hydrolysis of high molar mass conjugate esters as well as degradation of thermally labile compounds such as the derivatives of the diterpenes cafestol and kahweol. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Two-column sequential injection chromatography for fast isocratic separation of two analytes of greatly differing chemical properties.

    Science.gov (United States)

    Šatínský, Dalibor; Chocholouš, Petr; Válová, Olga; Hanusová, Lucia; Solich, Petr

    2013-09-30

    This paper deals with a novel approach to separate two analytes with different chemical properties and different lipophilicity. The newly described methodology is based on the two column system that was used for isocratic separation of two analytes with very different lipophilicity-dexamethasone and cinchocaine. Simultaneous separation of model compounds cinchocaine and dexamethasone was carried under the following conditions in two-column sequential injection chromatography system (2-C SIC). A 25×4.6 mm C-18 monolithic column was used in the first dimension for retention and separation of dexamethasone with mobile phase acetonitrile:water 30:70 (v/v), flow rate 0.9 mL min(-1) and consumption of 1.7 mL. A 10×4.6 mm C-18 monolithic column with 5×4.6 mm C-18 precolumn was used in the second dimension for retention and separation of cinchocaine using mobile phase acetonitrile:water 60:40 (v/v), flow rate 0.9 mL min(-1) and consumption 1.5 mL. Whole analysis time including both mobile phase's aspirations and both column separations was performed in less than 4 min. The method was fully validated and used for determination of cinchocaine and dexamethasone in pharmaceutical otic drops. The developed 2-C SIC method was compared with HPLC method under the isocratic conditions of separation on monolithic column (25×4.6 mm C-18). Spectrophotometric detection of both compounds was performed at wavelength 240 nm. System repeatability and method precision were found in the range (0.39-3.12%) for both compounds. Linearity of determination was evaluated in the range 50-500 μg mL(-1) and coefficients of determination were found to be r(2)=0.99912 for dexamethasone and r(2)=0.99969 for cinchocaine. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Schinus terebinthifolius countercurrent chromatography (Part III): Method transfer from small countercurrent chromatography column to preparative centrifugal partition chromatography ones as a part of method development.

    Science.gov (United States)

    das Neves Costa, Fernanda; Hubert, Jane; Borie, Nicolas; Kotland, Alexis; Hewitson, Peter; Ignatova, Svetlana; Renault, Jean-Hugues

    2017-03-03

    Countercurrent chromatography (CCC) and centrifugal partition chromatography (CPC) are support free liquid-liquid chromatography techniques sharing the same basic principles and features. Method transfer has previously been demonstrated for both techniques but never from one to another. This study aimed to show such a feasibility using fractionation of Schinus terebinthifolius berries dichloromethane extract as a case study. Heptane - ethyl acetate - methanol -water (6:1:6:1, v/v/v/v) was used as solvent system with masticadienonic and 3β-masticadienolic acids as target compounds. The optimized separation methodology previously described in Part I and II, was scaled up from an analytical hydrodynamic CCC column (17.4mL) to preparative hydrostatic CPC instruments (250mL and 303mL) as a part of method development. Flow-rate and sample loading were further optimized on CPC. Mobile phase linear velocity is suggested as a transfer invariant parameter if the CPC column contains sufficient number of partition cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Direct probing of chromatography columns by laser-induced fluorescence. Technical progress report, September 1, 1989--February 28, 1993

    Energy Technology Data Exchange (ETDEWEB)

    McGuffin, V.L.

    1992-12-07

    This report summarizes the progress and accomplishments of this research project from September 1, 1989 to February 28, 1993. During this period, we have accomplished all of the primary scientific objectives of the research proposal: (1) constructed and evaluated a laser-induced fluorescence detection system that allows direct examination of the chromatographic column, (2) examined nonequilibrium processes that occur upon solute injection and elution, (3) examined solute retention in liquid chromatography as a function of temperature and pressure, (4) examined solute zone dispersion in liquid chromatography as a function of temperature and pressure, and (5) developed appropriate theoretical models to describe these phenomena. In each of these studies, substantial knowledge has been gained of the fundamental processes that are responsible for chromatographic separations. In addition to these primary research objectives, we have made significant progress in three related areas: (1) examined pyrene as a fluorescent polarity probe insupercritical fluids and liquids as a function of temperature and pressure, (2) developed methods for the class-selective identification of polynuclear aromatic hydrocarbons in coal-derived fluids by microcolumn liquid chromatography with fluorescence quenching detection, and (3) developed methods for the determination of saturated and unsaturated (including omega-3) fatty acids in fish oil extracts by microcolumn liquid chromatography with laser-induced fluorescence detection. In these studies, the advanced separation and detection techniques developed in our laboratory are applied to practical problems of environmental and biomedical significance.

  19. Scalability of pre-packed preparative chromatography columns with different diameters and lengths taking into account extra column effects.

    Science.gov (United States)

    Schweiger, Susanne; Jungbauer, Alois

    2018-02-16

    Small pre-packed columns are commonly used to estimate the optimum run parameters for pilot and production scale. The question arises if the experiments obtained with these columns are scalable, because there are substantial changes in extra column volume when going from a very small scale to a benchtop column. In this study we demonstrate the scalability of pre-packed disposable and non-disposable columns of volumes in the range of 0.2-20 ml packed with various media using superficial velocities in the range of 30-500 cm/h. We found that the relative contribution of extra column band broadening to total band broadening was not only high for columns with small diameters, but also for columns with a larger volume due to their wider diameter. The extra column band broadening can be more than 50% for columns with volumes larger than 10 ml. An increase in column diameter leads to high additional extra column band broadening in the filter, frits, and adapters of the columns. We found a linear relationship between intra column band broadening and column length, which increased stepwise with increases in column diameter. This effect was also corroborated by CFD simulation. The intra column band broadening was the same for columns packed with different media. An empirical engineering equation and the data gained from the extra column effects allowed us to predict the intra, extra, and total column band broadening just from column length, diameter, and flow rate. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  20. Using the column wall itself as resistive heater for fast temperature gradients in liquid chromatography.

    Science.gov (United States)

    De Pauw, Ruben; Pursch, Matthias; Desmet, Gert

    2015-11-13

    A new system is proposed for applying fast temperature gradients in liquid chromatography. It consists of a 0.7 mm × 150 mm fused-silica column coated with a 50 μm Nickel-layer, which is connecting with a power source and a temperature control system to perform fast and reproducible temperature gradients using the column wall itself as a resistive heater. Applying a current of 4A and passive cooling results in a maximal heating and cooling rate of, respectively, 71 and -21 °C/min. Multi-segment temperature gradients were superimposed on mobile phase gradients to enhance the selectivity for three sets of mixtures (pharmaceutical compounds, a highly complex mixture and an insecticide sample). This resulted in a higher peak count or better selectivities for the various mixtures. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Electrochemically-modulated liquid chromatography (EMLC): Column design, retention processes, and applications

    Energy Technology Data Exchange (ETDEWEB)

    Ting, En -Yi [Iowa State Univ., Ames, IA (United States)

    1997-10-08

    This work describes the continued development of a new separation technique, electrochemically-modulated liquid chromatography (EMLC), from column design, retention mechanisms to pharmaceutical applications. The introduction section provides a literature review of the technique as well as a brief overview of the research in each of the chapters. This section is followed by four chapters which investigate the issues of EMLC column design, the retention mechanism of monosubstituted aromatic compounds, and the EMLC-based applications to two important classes of pharmaceutical compounds (i.e., corticosteroids and benzodiazepines). These four sections have been removed to process separately for inclusion on the database. The dissertation concludes with a general summary, a prospectus, and a list of references cited in the General Introduction. 32 refs.

  2. Separation of rare earth by column chromatography using organic resins XAD/DEPHA

    Energy Technology Data Exchange (ETDEWEB)

    Zini, J.; Ferreira, J.C.; Bergamaschi, V.S.; Santos, I.; Carvalho, F.M.S., E-mail: jcferrei@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (CCCH/IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Celulas a Combustivel e Hidrogenio

    2013-07-01

    The designation of light and heavy rare earth was used the fractionation used in separation processes. In this study the process of separation of rare earth, in groups, by chromatographic column consisting in fixing of cations these elements in an organic resin Amberlite XAD16 functionalized with the extracting agent DEPHA and another portion functionalized with a mixture of extractors DEPHA/TOP. The preparation of these resins was performed in two forms, one directly as the extracting agent to the resin and the other to be used in ethyl alcohol. Conditioned resins were introduced in chromatographic columns in separation of groups, light and heavy, using a standard solution of cerium nitrate and standard solution of holmium nitrate groups to represent light and heavy respectively. The characterization technique used to identify the rare earth elements was Spectrometry X-Ray Fluorescence (XRF). The results using the technique of chromatography were satisfactory, obtaining 100% separation of the elements. (author)

  3. Chlorine and bromine isotope fractionation of halogenated organic pollutants on gas chromatography columns.

    Science.gov (United States)

    Tang, Caiming; Tan, Jianhua; Xiong, Songsong; Liu, Jun; Fan, Yujuan; Peng, Xianzhi

    2017-09-08

    Compound-specific chlorine/bromine isotope analysis (CSIA-Cl/Br) has become a powerful approach to investigate degradation pathways and apportion sources of halogenated organic pollutants (HOPs) in the environment. CSIA-Cl/Br is usually conducted by gas chromatography-mass spectrometry (GC-MS), which could be negatively impacted by isotope fractionation on GC columns. In this study, on-column Cl/Br isotope fractionation of 31 organochlorines and 4 organobromines was explored using GC-double focus magnetic-sector high resolution MS (GC-DFS-HRMS). Twenty-nine HOPs exhibited inverse Cl/Br isotope fractionation for which the heavier isotopologues eluted faster than the lighter ones on GC columns, and two polychlorinated biphenyls (PCB-138 and PCB-153) showed normal isotope fractionation, whereas the rest four HOPs did not show observable isotope fractionation. The isotope fractionation extents varied from -13.0‰ to 73.1‰. Mechanisms of the on-column Cl/Br isotope fractionation were tentatively elucidated with a modified two-film model. The results demonstrate that integrating peak area as complete as possible for separable chromatographic peaks and integrating the middle retention-time segments for the inseparable peaks are helpful to improve precision and accuracy of the CSIA-Cl/Br data. The findings of this study will shed light on development of CSIA-Cl/Br methods with respect to improving precision and accuracy. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Surfactant-bound monolithic columns for separation of proteins in capillary high performance liquid chromatography.

    Science.gov (United States)

    Gu, Congying; He, Jun; Jia, Jinping; Fang, Nenghu; Simmons, Robert; Shamsi, Shahab A

    2010-01-22

    A surfactant-bound monolithic stationary phase based on the co-polymerization of 11-acrylamino-undecanoic acid (AAUA) is designed for capillary high performance liquid chromatography (HPLC). Using D-optimal design, the effect of the polymerization mixture (concentrations of monomer, crosslinker and porogens) on the chromatographic performance (resolution and analysis time) of the AAUA-EDMA monolithic column was evaluated. The polymerization mixture was optimized using three proteins as model test solutes. The D-optimal design indicates a strong dependence of chromatographic parameters on the concentration of porogens (1,4-butanediol and water) in the polymerization mixture. Optimized solutions for fast separation and high resolution separation, respectively, were obtained using the proposed multivariate optimization. Differences less than 6.8% between the predicted and the experimental values in terms of resolution and retention time indeed confirmed that the proposed approach is practical. Using the optimized column, fast separation of proteins could be obtained in 2.5 min, and a tryptic digest of myoglobin was successfully separated on the high resolution column. The physical properties (i.e., morphology, porosity and permeability) of the optimized monolithic column were thoroughly investigated. It appears that this surfactant-bound monolith may have a great potential as a new generation of capillary HPLC stationary phase. Copyright 2009 Elsevier B.V. All rights reserved.

  5. Surfactant-Bound Monolithic Columns for Separation of Proteins in Capillary High Performance Liquid Chromatography

    Science.gov (United States)

    Gu, Congying; He, Jun; Jia, Jinping; Fang, Nenghu; Simmons, Robert; Shamsi, Shahab A.

    2011-01-01

    A surfactant bound monolithic stationary phase based on the co-polymerization of 11-acrylamino-undecanoic acid (AAUA) is designed for capillary high performance liquid chromatography (HPLC). Using D-optimal design, the effect of the polymerization mixture (concentrations of monomer, crosslinker and porogens) on the chromatographic performance (resolution and analysis time) of the AAUA-EDMA monolithic column was evaluated. The polymerization mixture was optimized using three proteins as model test solutes. The D-optimal design indicates a strong dependence of chromatographic parameters on the concentration of porogens (1,4-butanediol and water) in the polymerization mixture. Optimized solutions for fast separation and high resolution separation, respectively, were obtained using the proposed multivariate optimization. Differences less than 6.8% between the predicted and the experimental values in terms of resolution and retention time indeed confirmed that the proposed approach is practical. Using the optimized column, fast separation of proteins could be obtained in 2.5 min, and a tryptic digest of myoglobin was successfully separated on the high resolution column. The physical properties (i.e. morphology, porosity and permeability) of the optimized monolithic column were thoroughly investigated. It appears that this surfactant-bound monolith may have a great potential as a new generation of capillary HPLC stationary phase. PMID:20031139

  6. Simple, specific analysis of organophosphorus and carbamate pesticides in sediments using column extraction and gas chromatography

    Science.gov (United States)

    Belisle, A.A.; Swineford, D.M.

    1988-01-01

    A simple, specific procedure was developed for the analysis of organophosphorus and carbamate pesticides in sediment. The wet soil was mixed with anhydrous sodium sulfate to bind water and the residues were column extracted in acetone:methylene chloride (1:l,v/v). Coextracted water was removed by additional sodium sulfate packed below the sample mixture. The eluate was concentrated and analyzed directly by capillary gas chromatography using phosphorus and nitrogen specific detectors. Recoveries averaged 93 % for sediments extracted shortly after spiking, but decreased significantly as the samples aged.

  7. Selection of column dimensions and gradient conditions to maximize the peak-production rate in comprehensive off-line two-dimensional liquid chromatography using monolithic columns

    NARCIS (Netherlands)

    Eeltink, S.; Dolman, S.; Vivo-Truyols, G.; Schoenmakers, P.; Swart, R.; Ursem, M.; Desmet, G.

    2010-01-01

    The peak-production rate (peak capacity per unit time) in comprehensive off-line two-dimensional liquid chromatography (LC/x/LC) was optimized for the separation of peptides using poly(styrene-co-divinylbenzene) monolithic columns in the reversed-phase (RP) mode. A first-dimension (D-1) separation

  8. Oxidative protein refolding on size exclusion chromatography: From batch single-column to multi-column counter-current continuous processing

    NARCIS (Netherlands)

    Saremirad, Pegah; Wood, Jeffery A.; Zhang, Yan; Ray, Ajay K.

    2015-01-01

    Recently protein refolding on size exclusion chromatography (SEC) operated in multi-column continuous simulated moving bed (SMB) configurations (hereinafter SMB-SEC) has been investigated for future industrial applications. This is due to several advantages offered by SMB configurations particularly

  9. Liquid chromatography coupled to on-line post column derivatization for the determination of organic compounds: a review on instrumentation and chemistries.

    Science.gov (United States)

    Zacharis, Constantinos K; Tzanavaras, Paraskevas D

    2013-10-10

    Analytical derivatization either in pre or post column modes is one of the most widely used sample pretreatment techniques coupled to liquid chromatography. In the present review article we selected to discuss the post column derivatization mode for the analysis of organic compounds. The first part of the review focuses to the instrumentation of post-column setups including not only fundamental components such as pumps and reactors but also less common parts such as static mixers and back-pressure regulators; the second part of the article discusses the most popular "chemistries" that are involved in post column applications, including reagent-less approaches and new sensing platforms such as the popular gold nanoparticles. Some representative recent applications are also presented as tables. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Standardization of the measurement of dihydro testosterone by radioimmunoassay by after celite column chromatography

    International Nuclear Information System (INIS)

    Lando, V.S.; Mendonca, B.B. de; Nicolau, W.

    1993-01-01

    We developed a method for measuring dihydro testosterone after previous chromatography. One ml of serum containing 1000 cpm of tritiated dihydro testosterone was extracted with hexane ethyl acetate (2:3) dried diluted with non saturated iso octane and injected in the column previously washed with 3.5 ml of pure iso octane. The serum was eluted from the column with pure iso octane (3.5 ml) followed by 5% ethyl acetate in iso octane. The quantity of tritiated dihydro testosterone which was recovered 50% and 80%in all assays. This paper measured dihydro testosterone e testosterone and testosterone/dihydro testosterone ratio in the following groups. GROUP I: Forty one normal adult subjects in basal conditions, with chronological age varying from 19 to 40 years old. GROUP II: Six normal adult subjects with chronological age between 21 and 33 years old, evaluated in basal conditions and after stimulus with 6000 UI of human chorionic Gonadotropin. GROUP III: Seven pre-puberal children with chronological age varying from 2 to 7 years old. GROUP IV: Eight patients with chronological age varying from 13 to 33 years old with male pseudo- hermaphroditism due to 5-alpha-reductase deficiency in basal conditions. This paper conclude that the measurement of dihydro testosterone in celite column chromatograph is an affordable, easy-to-perform method which was able to identify patients with male pseudo-hermaphroditism due to 5-alpha-reductase deficiency. (author)

  11. Host cell protein clearance during protein A chromatography: development of an improved column wash step.

    Science.gov (United States)

    Shukla, Abhinav A; Hinckley, Peter

    2008-01-01

    Host cell protein (HCP) contaminant clearance is a significant concern during downstream process development for biopharmaceuticals. Protein A chromatography as a capture step for monoclonal antibodies and Fc fusion proteins can clear a large proportion of these impurities from cell culture harvest. Nevertheless, remaining levels of this process-related impurity class do present significant constraints on the rapid development of effective and robust polishing steps. Conventionally, an intermediate pH wash is employed between column loading and elution to minimize HCP levels after Protein A chromatography. A significant mechanistic finding presented in this work is that HCP contaminants that persist following Protein A capture predominantly comprise species that associate with the product in preference to direct interaction with the chromatographic resin. This suggests that the development of improved column wash techniques to maximize HCP clearance ought to focus on disrupting protein-HCP interactions rather than Protein A-HCP interactions. A higher wash pH to preserve product--Protein A binding along with the use of additive combinations to disrupt interactions between HCPs and the product are investigated. This strategy was successfully applied to develop a broadly applicable wash condition that has the potential for eliminating the need for product specific optimization of wash conditions. A combination of 1 M urea and 10% isopropanol in the wash buffer were successfully applied as a platform wash condition for Protein A chromatography. Use of this (and other similar) wash conditions are anticipated to aid the rapid development of effective downstream processes for monoclonal antibodies and Fc fusion proteins resulting in their rapid introduction into clinical trials.

  12. Water quality monitoring system for determination of ionic nutrients by ion-exclusion chromatography with spectrophotometric detection on cation- and anion-exchange resin columns using water eluent.

    Science.gov (United States)

    Kozaki, Daisuke; Nakatani, Nobutake; Mori, Masanobu; Nakagoshi, Nobukazu; Tanaka, Kazuhiko

    2012-07-01

    A unified ion-exclusion chromatography (IEC) system for monitoring anionic and cationic nutrients like NH4+, NO2-, NO3-, phosphate ion, silicate ion and HCO3- was developed and applied to several environmental waters. The IEC system consisted of four IEC methodologies, including the IEC with ultraviolet (UV) form connected with detection at 210 nm for determining NH4+ on anion-exchange separation column in OH anion-exchange UV-conversion column in I- form in tandem, the IEC with UV-detection at 210 nm for determining simultaneously NO3- and NO3- on cation-exchange separation column in H+ form, the IEC with UV-detection at 210 nm for determining HCO3- on cation-exchange separation column in H+ form connected with anion-exchange UV-conversion column in I- form in tandem, and the IEC with visible-detection based on molybdenum-blue reaction for determining simultaneously silicate and phosphate ions on cation-exchange separation column in H+ form. These IEC systems were combined through three manually-driven 6-port column selection valves to select each separation column to determine selectively the ionic nutrients. Using this sequential water quality monitoring system, the analytical performances such as calibration linearity, reproducibility, detection limit and recovery were also tested under the optimized chromatographic conditions. This novel water quality monitoring system has been applied successfully for the determination of the ionic eutrophication components in sub-urban river waters.

  13. Multilayered particle-packed column: Evaluation and comparison with monolithic and core-shell particle columns for the determination of red azo dyes in Sequential Injection Chromatography.

    Science.gov (United States)

    Chocholouš, Petr; Gil, Renato; Acebal, Carolina C; Kubala, Viktor; Šatínský, Dalibor; Solich, Petr

    2017-03-01

    A recently presented new type of "multilayered" organic-inorganic hybrid silica particle packed column YMC-Triart C 18 (50 mm × 4.6 mm, 5 μm) was used for the development of a sequential injection chromatography method for determination of five azo dyes (Sudan I, Sudan II, Sudan III, Sudan orange G, and para red) in selected food seasonings. The use of a novel sorbent brings attractive features, reduced backpressure, and broader chemical stability together with high separation performance, which are discussed and compared with that of three types of columns typically used in medium-pressure flow chromatography techniques (classic monolithic, narrow monolithic, and core-shell particle columns). The separation was performed in gradient elution mode created by the zone mixing of two mobile phases (acetonitrile/water 90:10, 1.5 mL + acetonitrile/water 100:0, 2.3 mL) at a flow rate of 0.60 mL/min and time of analysis <9.5 min. The spectrophotometric detection wavelengths were set to 400, 480, and 500 nm. The high performance of the developed method with multilayered particle column was well documented and the results indicate a broad capability of sequential injection chromatography. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Efficiency of short, small-diameter columns for reversed-phase liquid chromatography under practical operating conditions.

    Science.gov (United States)

    Ma, Yan; Chassy, Alexander W; Miyazaki, Shota; Motokawa, Masanori; Morisato, Kei; Uzu, Hideyuki; Ohira, Masayoshi; Furuno, Masahiro; Nakanishi, Kazuki; Minakuchi, Hiroyoshi; Mriziq, Khaled; Farkas, Tivadar; Fiehn, Oliver; Tanaka, Nobuo

    2015-02-27

    Prototype small-size (1.0mm I.D., 5cm long) columns for reversed-phase HPLC were evaluated in relation to instrument requirements. The performance of three types of columns, monolithic silica and particulate silica (2μm, totally porous and 2.6μm, core-shell particles) was studied in the presence of considerable or minimal extra-column effects, while the detector contribution to band broadening was minimized by employing a small size UV-detector cell (6- or 90nL). A micro-LC instrument having small system volume (column band variance of only 0.01-0.02μL(2). The three columns generated about 8500 theoretical plates for solutes with retention factor, k>1-3 (depending on the column), in acetonitrile/water mobile phase (65/35=vol/vol) at 0.05mL/min, with the instrument specified above. The column efficiency was lower by up to 30% than that observed with a 2.1mm I.D. commercial column. The small-size columns also provided 8000-8500 theoretical plates for well retained solutes with a commercial ultrahigh-pressure liquid chromatography (UHPLC) instrument when extra-column contributions were minimized. While a significant extra-column effect was observed for early eluting solutes (kcolumn) with methanol/water (20/80=vol/vol) as weak-wash solvent, the use of methanol/water=50/50 as wash solvent affected the column efficiency for most analytes. The results suggest that the band compression effect by the weak-wash solvent associated with partial-loop injection may provide a practical means to reducing the extra-column effect for small-size columns, while the use of an instrument with minimum extra-column effect is highly desirable. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Preparation of polymer monolithic column functionalized by arsonic acid groups for mixed-mode capillary liquid chromatography.

    Science.gov (United States)

    Qin, Zhang-Na; Yu, Qiong-Wei; Wang, Ren-Qi; Feng, Yu-Qi

    2018-04-27

    A mixed-mode polymer monolithic column functionalized by arsonic acid groups was prepared by single-step in situ copolymerization of monomers p-methacryloylaminophenylarsonic acid (p-MAPHA) and pentaerythritol triacrylate (PETA). The prepared poly(p-MAPHA-co-PETA) monolithic column has a homogeneous monolithic structure with good permeability and mechanical stability. Zeta potential measurements reveal that the monolithic stationary phase holds a negative surface charge when the mobile phase resides in the pH range of 3.0-8.0. The retention mechanisms of prepared monolithic column are explored by the separation of selected polycyclic aromatic hydrocarbons (PAHs), nucleosides, and three basic compounds. The results indicate that the column functions in three different separation modes associated with reversed-phase chromatography based on hydrophobic interaction, hydrophilic interaction chromatography, and cation-exchange chromatography. The column efficiency of prepared monolithic column is estimated to be 70,000 and 76,000 theoretical plates/m for thiourea and naphthalene, respectively, at a linear flow velocity of 0.85 mm/s using acetonitrile/H 2 O (85/15, v/v) as the mobile phase. Furthermore, an analysis of the retention factors obtained for the PAHs indicates that the prepared monolithic column exhibits good reproducibility with relative standard deviations of 2.9%, 4.0%, and 4.7% based on run-to-run injections, column-to-column preparation, and batch-to-batch preparation, respectively. Finally, we investigate the separation performance of the proposed monolithic column for select phenols, sulfonamides, nucleobases and nucleosides. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Integration of On-Column Chemical Reactions in Protein Characterization by Liquid Chromatography/Mass Spectrometry: Cross-Path Reactive Chromatography.

    Science.gov (United States)

    Pawlowski, Jake W; Carrick, Ian; Kaltashov, Igor A

    2018-01-16

    Profiling of complex proteins by means of mass spectrometry (MS) frequently requires that certain chemical modifications of their covalent structure (e.g., reduction of disulfide bonds), be carried out prior to the MS or MS/MS analysis. Traditionally, these chemical reactions take place in the off-line mode to allow the excess reagents (the majority of which interfere with the MS measurements and degrade the analytical signal) to be removed from the protein solution prior to MS measurements. In addition to a significant increase in the analysis time, chemical reactions may result in a partial or full loss of the protein if the modifications adversely affect its stability, e.g,, making it prone to aggregation. In this work we present a new approach to solving this problem by carrying out the chemical reactions online using the reactive chromatography scheme on a size exclusion chromatography (SEC) platform with MS detection. This is achieved by using a cross-path reaction scheme, i.e., by delaying the protein injection onto the SEC column (with respect to the injection of the reagent plug containing a disulfide-reducing agent), which allows the chemical reactions to be carried out inside the column for a limited (and precisely controlled) period of time, while the two plugs overlap inside the column. The reduced protein elutes separately from the unconsumed reagents, allowing the signal suppression in ESI to be avoided and enabling sensitive MS detection. The new method is used to measure fucosylation levels of a plasma protein haptoglobin at the whole protein level following online reduction of disulfide-linked tetrameric species to monomeric units. The feasibility of top-down fragmentation of disulfide-containing proteins is also demonstrated using β 2 -microglobulin and a monoclonal antibody (mAb). The new online technique is both robust and versatile, as the cross-path scheme can be readily expanded to include multiple reactions in a single experiment (as

  17. Combining prior knowledge with data driven modeling of a batch distillation column including start-up

    NARCIS (Netherlands)

    van Lith, PF; Betlem, BHL; Roffel, B

    2003-01-01

    This paper presents the development of a simple model which describes the product quality and production over time of an experimental batch distillation column, including start-up. The model structure is based on a simple physical framework, which is augmented with fuzzy logic. This provides a way

  18. On-line separation of native proteins by two-dimensional liquid chromatography using a single column.

    Science.gov (United States)

    Geng, Xindu; Ke, Congyu; Chen, Gang; Liu, Peng; Wang, Fei; Zhang, Huiqiang; Sun, Xuan

    2009-04-17

    This paper reports the on-line separation of native (N) proteins by two-dimensional liquid chromatography (2D-LC) using a single column with one phase (called 2D column). The 2D column exhibits excellent resolution, selectivity, and retention of proteins in the N state and functions in two retention modes--hydrophobic interaction chromatography (HIC) and weak-cation exchange chromatography (WCX). We describe a new approach to on-line buffer exchange and collection of fractions from the first retention mode and their quantitative re-injection into the same column, followed by re-separation in the second retention mode. Thus, liquid chromatography in a closed system and in an on-line manner could be successfully carried out. This method was termed on-line protein separation by 2D-LC using only a single column (on-line 2D-LC-1C). The applicability of this method was experimentally demonstrated using standard proteins and a human serum sample. The total hypothetical maximum possible peak capacity n(c,total) and total sample peak capacity n(c,total)(*) of the 2D column were 329 and 199, respectively. By comparison against several popular commercially available columns, it was found that the 2D column had not only comparable resolution and better selectivity but also some unique characteristics. This 2D-LC-1C method could be applied to the fast purification of intact proteins in the N state, such protein drugs from natural products, and recombinant proteins and also for the fast pre-fractionation of intact proteins in the "top-down" MS strategy in proteomics.

  19. Temperature-assisted On-column Solute Focusing: A General Method to Reduce Pre-column Dispersion in Capillary High Performance Liquid Chromatography

    Science.gov (United States)

    Groskreutz, Stephen R.; Weber, Stephen G.

    2014-01-01

    Solvent-based on-column focusing is a powerful and well known approach for reducingthe impact of pre-column dispersion in liquid chromatography. Here we describe an orthogonal temperature-based approach to focusing called temperature-assisted on-column solute focusing (TASF). TASF is founded on the same principles as the more commonly used solvent-based method wherein transient conditions are created thatlead to high solute retention at the column inlet. Combining the low thermal mass of capillary columns and the temperature dependence of solute retentionTASF is used effectivelyto compress injection bands at the head of the column through the transient reduction in column temperature to 5 °C for a defined 7 mm segment of a 6 cm long 150 μm I.D. column. Following the 30 second focusing time, the column temperature is increased rapidly to the separation temperature of 60 °C releasing the focused band of analytes. We developed a model tosimulate TASF separations based on solute retention enthalpies, focusing temperature, focusing time, and column parameters. This model guides the systematic study of the influence of sample injection volume on column performance.All samples have solvent compositions matching the mobile phase. Over the 45 to 1050 nL injection volume range evaluated, TASF reducesthe peak width for all soluteswith k’ greater than or equal to 2.5, relative to controls. Peak widths resulting from injection volumes up to 1.3 times the column fluid volume with TASF are less than 5% larger than peak widths from a 45 nL injection without TASF (0.07 times the column liquid volume). The TASF approach reduced concentration detection limits by a factor of 12.5 relative to a small volume injection for low concentration samples. TASF is orthogonal to the solvent focusing method. Thus, it canbe used where on-column focusing is required, but where implementation of solvent-based focusing is difficult. PMID:24973805

  20. Modeling on-column reduction of trisulfide bonds in monoclonal antibodies during protein A chromatography.

    Science.gov (United States)

    Ghose, Sanchayita; Rajshekaran, Rupshika; Labanca, Marisa; Conley, Lynn

    2017-01-06

    Trisulfides can be a common post-translational modification in many recombinant monoclonal antibodies. These are a source of product heterogeneity that add to the complexity of product characterization and hence, need to be reduced for consistent product quality. Trisulfide bonds can be converted to the regular disulfide bonds by incorporating a novel cysteine wash step during Protein A affinity chromatography. An empirical model is developed for this on-column reduction reaction to compare the reaction rates as a function of typical operating parameters such as temperature, cysteine concentration, reaction time and starting level of trisulfides. The model presented here is anticipated to assist in the development of optimal wash conditions for the Protein A step to effectively reduce trisulfides to desired levels. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Effect of pre- and post-column band broadening on the performance of high-speed chromatography columns under isocratic and gradient conditions.

    Science.gov (United States)

    Vanderlinden, Kim; Broeckhoven, Ken; Vanderheyden, Yoachim; Desmet, Gert

    2016-04-15

    We report on the results of an experimental and theoretical study of the effect of the extra-column band broadening (ECBB) on the performance of narrow-bore columns filled with the smallest particles that are currently commercially available. Emphasis is on the difference between the effect of ECBB under gradient and isocratic conditions, as well as on the ability to model and predict the ECBB effects using well-established band broadening expressions available from the theory of chromatography. The fine details and assumptions that need to be taken into account when using these expressions are discussed. The experiments showed that, the steeper the gradient, the more pronounced the extra-column band broadening losses become. Whereas the pre-column band broadening can in both isocratic and gradient elution be avoided by playing on the possibilities to focus the analytes on top of the column (e.g. by using the POISe injection method when running isocratic separations), the post-column extra-column band broadening is inescapable in both cases. Inducing extra-column band broadening by changing the inner diameter of the post-column tubing from 65 to 250 μm, we found that all peaks in the chromatogram are strongly affected (around a factor of 1.9 increase in relative peak width) when running steep gradients, while usually only the first eluting peak was affected in the isocratic mode or when running shallow gradients (factor 1.6-1.8 increase in relative peak width for the first eluting analyte). Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Simultaneous Separation and Purification of Tea Bioactives from summer Green Tea by Column Chromatography

    International Nuclear Information System (INIS)

    Zhang, X.; Lei, S.C.; Sun, B.H.; ZENG, X.X.

    2013-01-01

    In the present study, feasibility of producing high quality of tea polyphenols, the anine and caffeine from the extract of summer green tea by column chromatography was investigated. Crude extract of summer green tea obtained by hot water extraction was passed through columns of polyamide and NKA-II macroporous resin respectively, resulting in tea polyphenols-enriched fraction (96.27 +- 1.78%), the anine-enriched fraction (99.02 +- 0.43%) and caffeine-enriched fraction (99.25 +- 0.36%). The recovery rates for tea polyphenols, the anine and caffeine were 72.42 +- 1.41%, 66.12 +- 1.66% and 62.07 +- 2.17%, respectively. The separation procedure allowed the production of such products by decreasing impurities and avoiding the use of poisonous organic solvent. The results suggested that it was possible to produce high-quality products of rich-in tea polyphenols, the anine and caffeine by a simple way. From industrial point of view, this novel method has many merits such as high efficiency of separation, low consumption of energy and environment-friendly procedure. (author)

  3. [Determination of ethylene glycol in workplace air by capillary column gas chromatography].

    Science.gov (United States)

    Li, Tiandi; Lin, Yiran; Zhang, Wen; He, Juntao

    2015-12-01

    To establish the method of capillary column gas chromatography for determination of ethylene glycol in workplace air. Ethylene glycol in workplace air was collected with silicone tube, desorbed with methanol, separated with FFAP (nitroterephthalic acid-modified polyethylene glycol)capillary column, and measured with flame ionization detector. The detection limit of ethylene glycol was 0.41 mg/L, the lower limit of quantification was 1.4 mg/L, the range of measurement was 1.4~163.9 mg/L, and the minimum detectable concentration was 0.3 mg/m3 (1.5 L of air was collected as the sample). This method had a good repeatability, the relative standard deviation was 1.4%~5.2%, the average desorption efficiency was 94.4%~101.7%, and the sampling efficiency was 99.2%~100%. The penetrating capacity of 200 mg silicone was higher than 6.9 mg, and the samples could be preserved for 14 days at room temperature. The method has a low detection limit, high accuracy, and good precision, which is feasible for determination of ethylene glycol in workplace air.

  4. Understanding and diminishing the extra-column band broadening effects in supercritical fluid chromatography.

    Science.gov (United States)

    De Pauw, Ruben; Shoykhet Choikhet, Konstantin; Desmet, Gert; Broeckhoven, Ken

    2015-07-17

    Supercritical fluid chromatography, where a low-viscosity mobile phase such as carbon dioxide is used, proves to be an excellent technique for fast and efficient separations, especially when sub-2μm particles are used. However, to achieve high velocities when using these small particles, and in order to stay within the flow rate range of current SFC-instruments, narrow columns (e.g. 2.1mm ID) must be used. Unfortunately, state-of-the-art instrumentation is limiting the full separation power of these narrower columns due to significant extra-column band broadening effects. The present work identifies and quantifies the different contributions to extra-column band broadening in SFC such as the influence of the sample solvent, injection volume, extra-column volumes and detector cell volume/design. When matching the sample solvent to the mobile phase in terms of elution strength and polarity (e.g. using hexane/ethanol/isopropanol 85/10/5vol%) and lowering the injection volume to 0.4μL, the plate count can be increased from 7600 to 21,300 for a low-retaining compound (k'=2.3) on a 2.1mm×150mm column (packed with 1.8μm particles). The application of a water/acetonitrile mixture as sample solvent was also investigated. It was found that when the volumetric ratio of water/acetonitrile was optimized, only a slightly lower plate count was measured compared to the hexane-based solvent when minimizing injection and extra-column volume. This confirms earlier results that water/acetonitrile can be used if water-soluble samples are considered or when a less volatile solvent is preferred. Minimizing the ID of the connection capillaries from 250 to 65μm, however, gives no further improvement in obtained efficiency for early-eluting compounds when a standard system configuration with optimized sample solvent was used. When switching to a state-of-the-art detector design with reduced (dispersion) volume (1.7-0.6μL), an increase in plate count is observed (from 11,000 to 14

  5. High-Efficiency On-Line Solid-Phase Extraction Coupling to 15-150 um I.D. Column Liquid Chromatography for Proteomic Analysis

    International Nuclear Information System (INIS)

    Shen, Yufeng; Moore, Ronald J.; Zhao, Rui; Blonder, Josip; Auberry, Deanna L.; Masselon, Christophe D.; Pasa Tolic, Ljiljana; Hixson, Kim K.; Auberry, Kenneth J.; Smith, Richard D.

    2003-01-01

    Flexible manipulation of various properties of proteomic samples is important for proteomic analyses, but it has been little explored for newly developed approaches based on liquid chromatography (LC) in combination with mass spectrometry (MS). With miniaturization of the LC column inner diameter dimensions (required for improving the analysis sensitivity), this issue becomes more challenging due to the small flow rates and the increasing effects of extra column volume on the separation quality and its use for resolving complex proteomic mixtures. In this study, we used commercial switching valves (150-mm channels) to implement the on-line coupling of capillary LC columns with relatively large solid phase extraction (SPE) columns operated at 10,000 psi. With optimized column connections, switching modes, and SPE column dimensions, high-efficiency on-line SPE-capillary and nanoscale LC separations were obtained with peak capacities of ∼1000 for capillaries having inner diameters between 15 to 150 mm. The on-line coupled SPE columns increased the sample processing capabilities by ∼400-fold for sample solution volume and ∼10-fold for sample mass. The proteomic applications of this on-line SPE-capillary LC system were evaluated for analysis of both soluble and membrane protein tryptic digests. Used with an ion trap tandem MS we could typically identify 1100-1500 peptides for analyses in a single 5-hour run. Peptides extracted on the SPE column and eluted from the LC column covered a hydrophilicity/hydrophobicity range that include an estimated ∼98% of all the tryptic peptides. The present implementation also facilitates automation and enables use of both disposable SPE columns and electrospray emitters, providing a robust basis for routine proteomic analyses.

  6. Evaluation of steric exclusion chromatography on cryogel column for the separation of serum proteins.

    Science.gov (United States)

    Wang, Chuan; Bai, Shu; Tao, Shi-Peng; Sun, Yan

    2014-03-14

    Steric exclusion chromatography (SXC) is a new mode of protein chromatography, in which large proteins are retained on hydrophilic stationary phase surface due to the steric exclusion of polyethylene glycol (PEG) in the mobile phase, and thereafter the retained proteins can be eluted by reducing PEG concentration. In this work, SXC was evaluated on a polyacrylamide cryogel monolith. Microscopic observation of γ-globulin precipitates on the gel surface in SXC was reported for the first time. Due to the compact packing of protein precipitates on the stationary phase surface, the dynamic retention capacity of the cryogel monolith for γ-globulin reached 20 mg/mL bed volume, much higher than those of cryogel beds in adsorption-based chromatography. The effect of molecular weight and concentration of PEG, solution pH and salt concentration on protein retention capacity was in agreement with the earlier work on SXC. Because the cryogel monoliths with interconnected macropores (10-100 μm) allow much easy flow-through of viscous PEG buffer, the SXC can be operated at low back pressure. Hence, the cryogel monoliths are more suitable for SXC than other monoliths of narrow pores reported previously. In the separation of bovine serum proteins, albumin was recovered in the breakthrough fraction with high purity, and globulin was over eight times concentrated in the elution pool. This work has, thus, demonstrated the rapid serum protein separation and concentration by SXC on the cryogel monolith columns. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Selection of column dimensions and gradient conditions to maximize the peak-production rate in comprehensive off-line two-dimensional liquid chromatography using monolithic columns.

    Science.gov (United States)

    Eeltink, Sebastiaan; Dolman, Sebastiaan; Vivo-Truyols, Gabriel; Schoenmakers, Peter; Swart, Remco; Ursem, Mario; Desmet, Gert

    2010-08-15

    The peak-production rate (peak capacity per unit time) in comprehensive off-line two-dimensional liquid chromatography (LC/x/LC) was optimized for the separation of peptides using poly(styrene-co-divinylbenzene) monolithic columns in the reversed-phase (RP) mode. A first-dimension ((1)D) separation was performed on a monolithic column operating at a pH of 8, followed by sequential analysis of all the (1)D fractions on a monolithic column operating at a pH of 2. To obtain the highest peak-production rate, effects of column length, gradient duration, and sampling time were examined. RP/x/RP was performed at undersampling conditions using a short 10 min (1)D gradient. The peak-production rate was highest using a 50 mm long (2)D column applying an 8-10 min (2)D gradient time and was almost a factor of two higher than when a 250 mm monolithic column was used. The best way to obtain a higher peak-production rate in off-line LC/x/LC proved to be an increase in the number of (1)D fractions collected. Increasing the (2)D gradient time was less effective. The potential of the optimized RP/x/RP method is demonstrated by analyzing proteomics samples of various complexities. Finally, the trade-off between peak capacity and analysis time is discussed in quantitative terms for both one-dimensional RP gradient-elution chromatography and the off-line two-dimensional (RP/x/RP) approach. At the conditions applied, the RP/x/RP approach provided a higher peak-production rate than the (1)D-LC approach when collecting three (1)D fractions, which corresponds to a total analysis time of 60 min.

  8. Sensitive absorption detection for micro-column liquid chromatography by ultraviolet forward-scattering degenerate four-wave mixing.

    NARCIS (Netherlands)

    de Beer, T.; Beso, P.; Velthorst, N.H.; Brinkman, U.A.T.; Gooijer, C.; Hoornweg, G.Ph.

    1999-01-01

    The performance of forward-scattering degenerate four-wave mixing (F-D4WM) in the mid-ultraviolet (UV) region (351nm) as a detection technique for micro-column liquid chromatography (μLC) is studied, using nitro-substituted polycyclic aromatic hydrocarbons (NO

  9. Analysis of polycyclic aromatic hydrocarbons I. Determination by gas chromatography with glass and fused silica capillary columns

    International Nuclear Information System (INIS)

    Perez, M. M.; Gonzalez, D.

    1987-01-01

    A study of the analysis by gas chromatography of aromatic polycyclic hydrocarbons is presented. The separation has been carried out by glass and fused silica capillary column. The limitations and the advantages of the procedure are discussed in terms of separation efficiency, sensitivity and precision. (Author) 17 refs

  10. Boehringer immunoinhibition procedure for creatine kinase-MB evaluated and compared with column ion-exchange chromatography

    NARCIS (Netherlands)

    ter Welle, H. F.; Baartscheer, T.; Fiolet, J. W.

    1983-01-01

    In determination of creatine kinase isoenzyme MB (CK-MB), the Boehringer immunoinhibition method gives a high and variable blank activity as compared with column-chromatography. Thus a correction must be applied. Furthermore, a second correction of 1% of total creatine kinase activity is necessary

  11. Analysis of polycyclic aromatic hydrocarbons. I. Determination by gas chromatography with glass and fused solica capillary columns

    International Nuclear Information System (INIS)

    Perez Garcia, M.; Gonzalez, D.

    1987-01-01

    A study of the analysis by gas chromatography of aromatic polycyclic hydrocarbons is presented. The separation has been carried out by glass and fused silice capillary column. The limitations and the advantages of the procedure are discussed in terms of separation efficiency, sensitivity and precision. (author). 3 figs., 17 refs

  12. Using Artificial Soil and Dry-Column Flash Chromatography to Simulate Organic Substance Leaching Process: A Colorful Environmental Chemistry Experiment

    Science.gov (United States)

    de Avellar, Isa G. J.; Cotta, Tais A. P. G.; Neder, Amarilis de V. Finageiv

    2012-01-01

    Soil is an important and complex environmental compartment and soil contamination contributes to the pollution of aquifers and other water basins. A simple and low-cost experiment is described in which the mobility of three organic compounds in an artificial soil is examined using dry-column flash chromatography. The compounds were applied on top…

  13. At-line hyphenation of high-speed countercurrent chromatography with Sephadex LH-20 column chromatography for bioassay-guided separation of antioxidants from vine tea (Ampelopsis grossedentata).

    Science.gov (United States)

    Ma, Ruyi; Zhou, Rongrong; Tong, Runna; Shi, Shuyun; Chen, Xiaoqing

    2017-01-01

    Vine tea (Ampelopsis grossedentata), a widely used healthy tea, beverage and herbal medicine, exhibited strong antioxidant activity. However, systematic purification of antioxidants, especially for those with similar structures or polarities, is a challenging work. Here, we present a novel at-line hyphenation of high-speed countercurrent chromatography with Sephadex LH-20 column chromatography (HSCCC-Sephadex LH-20 CC) for rapid and efficient separation of antioxidants from vine tea target-guided by 1,1-diphenyl-2-picryl-hydrazyl radical-high performance liquid chromatography (DPPH-HPLC) experiment. A makeup pump, a six-port switching valve and a trapping column were served as interface. The configuration had no operational time and mobile phase limitations between two dimensional chromatography and showed great flexibility without tedious sample-handling procedure. Seven targeted antioxidants were firstly separated by stepwise HSCCC using petroleum ether-ethyl acetate-methanol-water (4:9:4:9, v/v/v/v) and (4:9:5:8, v/v/v/v) as solvent systems, and then co-eluted antioxidants were on-line trapped, concentrated and desorbed to Sephadex LH-20 column for further off-line purification by methanol. It is noted that six elucidated antioxidants with purity over 95% exhibited stronger activity than ascorbic acid (VC). More importantly, this at-line hyphenated strategy could sever as a rapid and efficient pathway for systematic purification of bioactive components from complex matrix. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Hydrophilic interaction chromatography using a meter-scale monolithic silica capillary column for proteomics LC-MS.

    Science.gov (United States)

    Horie, Kanta; Kamakura, Takeo; Ikegami, Tohru; Wakabayashi, Masaki; Kato, Takashi; Tanaka, Nobuo; Ishihama, Yasushi

    2014-04-15

    A meter-scale monolithic silica capillary column modified with urea-functional groups for hydrophilic interaction liquid chromatography (HILIC) was developed for highly efficient separation of biological compounds. We prepared a ureidopropylsilylated monolithic silica capillary column with a minimum plate height of 12 μm for nucleosides and a permeability of 2.1 × 10(-13) m(2), which is comparable with the parameters of monolithic silica-C18 capillary columns. Over 300,000 theoretical plates were experimentally obtained in HILIC with a 4 m long column at 8 MPa; this is the best result yet reported for HILIC. A 2 m long ureidopropylsilylated monolithic silica capillary column was utilized to develop a HILIC mode LC-MS system for proteomics applications. Using tryptic peptides from human HeLa cell lysate proteins, we identified the comparable numbers of peptides and proteins in HILIC with those in reversed-phase liquid chromatography (RPLC) using a C18-modified monolithic silica column when shallow gradients were applied. In addition, approximately 5-fold increase in the peak response on average was observed in HILIC for commonly identified tryptic peptides due to the high acetonitrile concentration in the HILIC mobile phase. Since HILIC mode LC-MS shows orthogonal selectivity to RPLC mode LC-MS, it is useful as a complementary tool to increase proteome coverage in proteomics studies.

  15. Micro-fabricated semi-packed column for gas chromatography by using functionalized parylene as a stationary phase

    International Nuclear Information System (INIS)

    Nakai, T; Nishiyama, S; Shuzo, M; Delaunay, J-J; Yamada, I

    2009-01-01

    The conformal coating of effective stationary phases onto micro-fabricated columns having complex geometries such as semi-packed columns poses a real challenge. Here, we report for the first time the conformal coating of a semi-packed column with amino-functionalized parylene diX-AM (poly-aminomethyl-[2,2]-paracyclophane), which was found to be an effective stationary-phase material for the chromatography of short-retention-time compounds. A semi-packed column (consisting of a zigzag array of 30 µm square micro-pillars in a 1.0 m long, 180 µm wide and 230 µm deep channel) and an open tubular column (1.0 m long, 160 µm wide and 230 µm deep channel) used for comparison purposes were micro-fabricated on silicon that was subsequently coated with diX-AM parylene and thermally bonded. The chromatograms recorded on a commercial gas chromatograph demonstrated the usefulness of the conformal diX-AM coating as a stationary phase for semi-packed columns. The separation efficiency of the semi-packed column was found to be more than ten times that of the open tubular column

  16. Online micro-solid-phase extraction based on boronate affinity monolithic column coupled with high-performance liquid chromatography for the determination of monoamine neurotransmitters in human urine.

    Science.gov (United States)

    Yang, Xiaoting; Hu, Yufei; Li, Gongke

    2014-05-16

    Quantification of monoamine neurotransmitters is very important in diagnosing and monitoring of patients with neurological disorders. We developed an online analytical method to selectively determine urinary monoamine neurotransmitters, which coupled the boronate affinity monolithic column micro-solid-phase extraction with high-performance liquid chromatography (HPLC). The boronate affinity monolithic column was prepared by in situ polymerization of vinylphenylboronic acid (VPBA) and N,N'-methylenebisacrylamide (MBAA) in a stainless capillary column. The prepared monolithic column showed good permeability, high extraction selectivity and capacity. The column-to-column reproducibility was satisfactory and the enrichment factors were 17-243 for four monoamine neurotransmitters. Parameters that influence the online extraction efficiency, including pH of sample solution, flow rate of extraction and desorption, extraction volume and desorption volume were investigated. Under the optimized conditions, the developed method exhibited low limit of detection (0.06-0.80μg/L), good linearity (with R(2) between 0.9979 and 0.9993). The recoveries in urine samples were 81.0-105.5% for four monoamine neurotransmitters with intra- and inter-day RSDs of 2.1-8.2% and 3.7-10.6%, respectively. The online analytical method was sensitive, accurate, selective, reliable and applicable to analysis of trace monoamine neurotransmitters in human urine sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Caprylic acid-induced impurity precipitation from protein A capture column elution pool to enable a two-chromatography-step process for monoclonal antibody purification.

    Science.gov (United States)

    Zheng, Ji; Wang, Lu; Twarowska, Barbara; Laino, Sarah; Sparks, Colleen; Smith, Timothy; Russell, Reb; Wang, Michelle

    2015-01-01

    This article presents the use of caprylic acid (CA) to precipitate impurities from the protein A capture column elution pool for the purification of monoclonal antibodies (mAbs) with the objective of developing a two chromatography step antibody purification process. A CA-induced impurity precipitation in the protein A column elution pool was evaluated as an alternative method to polishing chromatography techniques for use in the purification of mAbs. Parameters including pH, CA concentrations, mixing time, mAb concentrations, buffer systems, and incubation temperatures were evaluated on their impacts on the impurity removal, high-molecular weight (HMW) formation and precipitation step yield. Both pH and CA concentration, but not mAb concentrations and buffer systems, are key parameters that can affect host-cell proteins (HCPs) clearance, HMW species, and yield. CA precipitation removes HCPs and some HMW species to the acceptable levels under the optimal conditions. The CA precipitation process is robust at 15-25°C. For all five mAbs tested in this study, the optimal CA concentration range is 0.5-1.0%, while the pH range is from 5.0 to 6.0. A purification process using two chromatography steps (protein A capture column and ion exchange polishing column) in combination with CA-based impurity precipitation step can be used as a robust downstream process for mAb molecules with a broad range of isoelectric points. Residual CA can be effectively removed by the subsequent polishing cation exchange chromatography. © 2015 American Institute of Chemical Engineers.

  18. Experimental investigation of liquid chromatography columns by means of computed tomography

    DEFF Research Database (Denmark)

    Astrath, D.U.; Lottes, F.; Vu, Duc Thuong

    2007-01-01

    dispersive model (EDM) and varying the so called apparent axial dispersion coefficient. The additivity of the first and second central moments was exploited to estimate column efficiency in different regions of the column. The results showed that the columns under investigation offered a higher column...

  19. Two-column sequential injection chromatography--new approach for fast and effective analysis and its comparison with gradient elution chromatography.

    Science.gov (United States)

    Chocholous, Petr; Satínský, Dalibor; Sklenárová, Hana; Solich, Petr

    2010-05-23

    This work presents novel approach in low-pressure chromatography flow systems--two-column Sequential Injection Chromatography (2-C SIC) and its comparison with gradient elution chromatography on the same instrument. The system was equipped with two different chromatographic columns (connected to selection valve in parallel design) for isocratic separation and determination of all components in composed anti-inflammatory pharmaceutical preparation (tablets). The sample was first injected on the first column of length 30 mm where less retained analytes were separated and then the sample was injected on the second column of length 10 mm where more retained analytes were separated. The SIC system was based on a commercial SIChrom manifold (8-port high-pressure selection valve and medium-pressure syringe pump with 4 mL reservoir) (FIAlab, USA) with two commercially available monolithic columns the "first column" Chromolith Flash RP-18e (25 mm x 4.6 mm i.d. with guard column 5 mm x 4.6 mm i.d.) and the "second column" Chromolith RP-18e (10 mm x 4.6 mm i.d.) and CCD UV-vis detector USB 4000 with micro-volume 1.0 cm Z flow cell. Two mobile phases were used for analysis (one for each column). The mobile phase 1 used for elution of paracetamol, caffeine and salicylic acid (internal standard) was acetonitrile/water (10:90, v/v, the water part of pH 3.5 adjusted with acetic acid), flow rate was 0.9 mL min(-1) (volume 3.0 mL of mobile phase per analysis). The mobile phase 2 used for elution of propyphenazone was acetonitrile/water (30:70, v/v); flow rate was 1.2 mL min(-1) (volume 1.5 mL of mobile phase per analysis). Absorbance was monitored at 210 nm. Samples were prepared by dissolving of one tablet in 30% acetonitrile and 10 microL of filtered supernatant was injected on each column (2 x 10 microL). The chromatographic resolution between all compounds was >1.45 and analysis time was 5.5 min under the optimal conditions. Limits of detection were determined at 0.4 microg m

  20. Preparation of organic-silica hybrid monolithic columns via crosslinking of functionalized mesoporous carbon nanoparticles for capillary liquid chromatography.

    Science.gov (United States)

    Liu, Shengju; Peng, Jiaxi; Zhang, Hongyan; Li, Xin; Liu, Zheyi; Kang, Xiaohui; Wu, Minghuo; Wu, Ren'an

    2017-05-19

    An organic-silica hybrid monolithic capillary column was fabricated by crosslinking (3-aminopropyl)trimethoxysilane (APTMS) modified mesoporous carbon nanoparticles (AP-MCNs) with tetramethoxysilane (TMOS) and n-butyltrimethoxysilane (C4-TriMOS). Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy, mercury intrusion porosimetry and inverse size-exclusion chromatography characterization proved the successful immobilization of mesoporous carbon nanoparticles (MCNs). The crosslinking of AP-MCNs into the hybrid monolithic matrix has significantly increased the reversed-phase retention of alkylbenzenes and chromatographic performance for small molecules separations in comparison with the neat one without MCNs. The resulting column efficiency of the mesoporous carbon nanoparticle-based butyl-silica hybrid monolithic column (MCN-C4-monolith) was up to ca. 116,600N/m for the capillary liquid chromatography (cLC) separation of butylbenzene. Enhanced performance of proteins separation was achieved on the MCN-C4-monolith in comparison with the butyl-silica hybrid monolithic column without MCN (C4-monolith). The separation of peptides from bovine serum albumin (BSA) digest was carried out on the MCN-C4-monolith by capillary liquid chromatography-tandem mass spectrometry (cLC-MS/MS) with protein sequence coverage of 81.9%, suggesting its potential application in proteomics. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Simultaneous chirality and enantiomer separation of metallic single-wall carbon nanotubes by gel column chromatography.

    Science.gov (United States)

    Tanaka, Takeshi; Urabe, Yasuko; Hirakawa, Takuya; Kataura, Hiromichi

    2015-09-15

    We report the chirality and enantiomer separation of metallic single-wall carbon nanotubes (SWCNTs) using gel chromatography, which has been the last remaining issue in SWCNT separation that has yet to be achieved. The key to the separation is summarized as the following three points: (i) the use of a preseparated metallic SWCNT mixture to eliminate the semiconducting SWCNTs that are more interactive with the gel; (ii) the reduction of the concentration of dispersant to increase the interaction between the metallic SWCNTs and the gel; and (iii) the use of a long column to increase the number of interaction sites that enhance the slight differences between metallic SWCNT species. Using these three separation conditions, we obtained chirality-sorted metallic SWCNTs, especially (10,4) metallic SWCNTs were highly enriched. Circular dichroism spectra demonstrated the enantiomer separation of metallic SWCNTs. The discrimination of the enantiomers is derived from the dextran in the gel, which is the only enantiomeric moiety in this system. This is the first report on the enantiomer separation of metallic SWCNTs and will contribute to progress in the fundamental physics and applications of SWCNTs.

  2. Enrichment and purification of gardenia yellow from Gardenia jasminoides var. radicans Makino by column chromatography technique.

    Science.gov (United States)

    Chen, Jian-Fang; Fu, Gui-Ming; Wan, Yin; Liu, Cheng-Mei; Chai, Jian-Xin; Li, Hong-Ge; Wang, Jian-Tao; Ming-Hu; Zhang, Lun-Ning

    2012-04-15

    In present study, the performance and separation characteristics of nine macroporous resins for the enrichment and purification of gardenia yellow from Gardenia jasminoides var. radicans Makino have been evaluated. The adsorption and desorption properties of crude gardenia yellow solution on macroporous resins including HPD722, HPD100, HPD100A, HPD400, HPD400A, D101, AB-8, XAD-16, and NKA-9 have been compared. Then, HPD722 was chosen to purify gardenia yellow because of its strong adsorption and desorption abilities as well as high selectivity. Column packed with HPD722 resin was used to perform dynamic adsorption and desorption tests to optimize the separation process of gardenia yellow. The optimal conditions were as follows: The crude gardenia yellow solution with concentration of 15 mg/mL was loaded in column packed with HPD722 resin at the flow rate of 1.0 mL/min, and the adsorbate-laden column was washed with 800 mL water, 600 mL 15% ethanol water solution respectively at the speed of 2.5 mL/min, then desorbed with 200 mL 80% ethanol water solution at the speed of 3.5 mL/min. The colority of the product obtained were up to 300. The method developed in this study provides a new approach for scale-up separation and purification of gardenia yellow from G. jasminoides var. radicans Makino. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. [Preparation of new hydrophilic monolithic columns and their applications in capillary liquid chromatography and pressurized capillary electrochromatography].

    Science.gov (United States)

    Gao, Ye; Wang, Yan; Wang, Chaoran; Gu, Xue; Yan, Chao

    2012-05-01

    New hydrophilic monolithic columns were prepared with {[3-(methacryloylamino) propyl] dimethyl(3-sulfopropyl)ammonium hydroxide inner salt (SPP)} as monomer, pentaerythritol triacrylate (PETA) as crosslinking agent, azobisisobutyronitrile (AIBN) as initiator with two different porogens consisting of ethanol/ethylene glycol and methanol/1 ,4-butanediol, separately. In order to obtain monolithic columns with satisfactory efficiency, electroosmotic flow (EOF) velocity and permeability, the contents of the polymerization mixture were investigated and optimized. The performances of the two columns were compared in the permeability and separation performance. It was found that the monolithic column prepared with ethanol/ ethylene glycol had a better column efficiency and selectivity than that with methanol/1,4-butanediol, but was inferior to the latter in permeability. The effect of salt concentration (from 10 to 70 mmol/L ammonium formate) on the retention of nucleosides was investigated. It was observed that the retention factors of these nucleosides increased at first and then decreased. The columns were used in capillary liquid chromatography (cLC) and pressurized capillary electrochromatography (pCEC) for the separation of a test mixture of amines, phenols and nucleosides separately, and satisfactory separations for these samples were achieved. The column used in pCEC system showed better separation and higher speed of the mixture consisted of phenols and nucleosides compared to those used in cLC system.

  4. The preparation of a poly (pentaerythritol tetraglycidyl ether-co-poly ethylene imine) organic monolithic capillary column and its application in hydrophilic interaction chromatography for polar molecules.

    Science.gov (United States)

    Chen, Ye; Shu, Yan; Yang, Zihui; Lv, Xumei; Tan, Wangming; Chen, Yingzhuang; Ma, Ming; Chen, Bo

    2017-10-02

    An easy single-step thermal treatment "one-pot" approach for the preparation of poly (pentaerythritol tetraglycidyl ether-co-poly ethylene imine) organic monolithic capillary columns was developed successfully. The column was prepared by the epoxy-amine ring-opening polymerization of pentaerythritol tetraglycidyl ether (PTE) with poly (ethylene imine) (PEI) using acetonitrile (ACN) and polyethylene glycol 600 (PEG 600) as the porogenic system at 60 °C for 12 h. The obtained monolith was homogeneous and permeable. It achieved the high-efficiency separation of polar molecules including amides, nucleosides, bases, phenols, and benzoic acids in capillary liquid chromatography (cLC). The highest column efficiency reached ca. 101,000 plates/m (for guanine) on monolith poly(PTE-co-PEI) at 0.64 mm/s, and satisfactory chromatographic performance with column efficiencies ranged from 45,500 to 97,000 plates/m was achieved for the four amides. A typical hydrophilic interaction liquid chromatography (HILIC) retention mechanism was observed with high organic solvent contents (>60% ACN). Also, the polymer-based monolithic column was successfully applied to separate the tumor markers. Furthermore, the poly(PTE-co-PEI) monolith could be easily modified with 1, 2-epoxydodecane, which reacted with the amino groups presented on the surface of the poly(PTE-co-PEI) monolith. Hydrophobic interactions were observed during the separation of alkylbenzenes and anilines on the post-modified poly(PTE-co-PEI) monolith. Together, these results confirm the feasibility of the epoxy-amine ring-opening polymerization reaction during the fabrication of a monolithic column with high efficiency for cLC applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Seismic performance of square RC bridge columns under combined loading including torsion with low shear.

    Science.gov (United States)

    2009-12-01

    During earthquake excitations, reinforced concrete bridge columns can be subjected to a combination of axial load, shear force, : flexural moments, and torsional moments. The torsional moment can be much more significant in columns of bridges that ar...

  6. Separation and purification of three stilbenes from the radix of Polygonum cillinerve (Nakai Ohwl by macroporous resin column chromatography combined with high-speed counter-current chromatography

    Directory of Open Access Journals (Sweden)

    Xiaofeng Chi

    2014-01-01

    Full Text Available An effective method for the rapid separation and purification of three stilbenes from the radix of Polygonum cillinerve (Nakai Ohwl by macroporous resin column chromatography combined with high-speed counter-current chromatography (HSCCC was successfully established. In the present study, a two-phase solvent system composed of chloroform-n-butanol-methanol-water (4:1:4:2, v/v/v/v was used for HSCCC separation. A one-step separation in 4 h from 150 mg of crude extract produced 26.3 mg of trans-resveratrol-3-O-glucoside, 42.0 mg of pieceid-2"-O-gallate, and 17.9 mg of trans-resveratrol with purities of 99.1%, 97.8%, and 99.4%, respectively, as determined by high-performance liquid chromatography (HPLC. The chemical structures of these compounds were identified by nuclear magnetic resonance (NMR spectroscopy.

  7. Design of two-column batch-to-batch recirculation to enhance performance in ion-exchange chromatography.

    Science.gov (United States)

    Persson, Oliver; Andersson, Niklas; Nilsson, Bernt

    2018-01-05

    Preparative liquid chromatography is a separation technique widely used in the manufacturing of fine chemicals and pharmaceuticals. A major drawback of traditional single-column batch chromatography step is the trade-off between product purity and process performance. Recirculation of impure product can be utilized to make the trade-off more favorable. The aim of the present study was to investigate the usage of a two-column batch-to-batch recirculation process step to increase the performance compared to single-column batch chromatography at a high purity requirement. The separation of a ternary protein mixture on ion-exchange chromatography columns was used to evaluate the proposed process. The investigation used modelling and simulation of the process step, experimental validation and optimization of the simulated process. In the presented case the yield increases from 45.4% to 93.6% and the productivity increases 3.4 times compared to the performance of a batch run for a nominal case. A rapid concentration build-up product can be seen during the first cycles, before the process reaches a cyclic steady-state with reoccurring concentration profiles. The optimization of the simulation model predicts that the recirculated salt can be used as a flying start of the elution, which would enhance the process performance. The proposed process is more complex than a batch process, but may improve the separation performance, especially while operating at cyclic steady-state. The recirculation of impure fractions reduces the product losses and ensures separation of product to a high degree of purity. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Column extraction chromatography with HEH (EHP) for separating rare earth elements from coexistent elements and its application

    International Nuclear Information System (INIS)

    Peng Chunlin; Sun Baocheng; Zhao Junwu; Liu Xuan

    1985-01-01

    For separating rare earths from large amount of coexistent elements a new method of column extraction chromatography with HEH (EHP) as a stationary phase and sulphosalicylic acid, gluconic acid, ascorbic acid respectively as a mobile phase has been developed. It has been applied to the determination of trace rare earth elements in nickel-base alloys and iron-nickel-base alloys with satisfactory results

  9. Separation of hexabromocyclododecane diastereomers: Application of C18 and phenyl-hexyl ultra-performance liquid chromatography columns.

    Science.gov (United States)

    Baek, Song-Yee; Lee, Sunyoung; Kim, Byungjoo

    2017-03-10

    This study was performed to establish the proper liquid chromatographic conditions for the separation of hexabromocyclododecane (HBCD) diastereomers. Column selectivity towards HBCD diastereomers was evaluated for C18 and phenyl-hexyl stationary phases. First, the baseline separation of the primary HBCDs (α-, β-, and γ-HBCD) was obtained using the ultra-performance liquid chromatography (UPLC) column with C18 stationary phase chosen in most previous studies for HBCD analysis; however, co-elution of δ- and ε-HBCD with the primary HBCD diastereomers was observed. To prevent the interference from δ- and ε-HBCD, we adopted a phenyl-hexyl UPLC column to resolve the HBCD diastereomers. The phenyl-hexyl UPLC column showed significantly different selectivity for the HBCD diastereomers compared with the C18 column, which allowed the clear isolation of δ-HBCD and ε-HBCD from the primary HBCD diastereomers. In addition, by checking the retention times of all HBCD diastereomers using both C18 and phenyl-hexyl columns, we confirmed the presence of δ-, ε-, η-, and θ-HBCDs in two technical HBCD mixtures. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Poly[hydroxyethyl acrylate-co-poly(ethylene glycol) diacrylate] monolithic column for efficient hydrophobic interaction chromatography of proteins.

    Science.gov (United States)

    Li, Yuanyuan; Tolley, H Dennis; Lee, Milton L

    2009-11-15

    Rigid poly[hydroxyethyl acrylate-co-poly(ethylene glycol) diacrylate] monoliths were synthesized inside 75 mum i.d. capillaries by one-step UV-initiated copolymerization using methanol and ethyl ether as porogens. The optimized monolithic column was evaluated for hydrophobic interaction chromatography (HIC) of standard proteins. Six proteins were separated within 20 min with high resolution using a 20 min elution gradient, resulting in a peak capacity of 54. The effect of gradient rate and initial salt concentration on the retention of proteins were investigated. Mass recovery was found to be greater than 96%, indicating the biocompatibility of this monolith. The monolith was mechanically stable and showed nearly no swelling or shrinking in different polarity solvents. The preparation of this in situ polymerized acrylate monolithic column was highly reproducible. The run-to-run and column-to-column reproducibilities were less than 2.0% relative standard deviation (RSD) on the basis of the retention times of protein standards. The performance of this monolithic column for HIC was comparable or superior to the performance of columns packed with small particles.

  11. Research on the separation properties of empty-column gas chromatography (EC-GC) and conditions for simulated distillation (SIMDIS).

    Science.gov (United States)

    Boczkaj, Grzegorz; Kamiński, Marian

    2013-10-01

    Previous studies have revealed it is possible to separate a high-boiling mixture by gas chromatography in empty fused-silica capillary tubing rather than in columns coated with stationary phase. Chromatographic separation occurs solely on the basis of the different boiling points of the substances separated. The high similarity of such separations to those in classic distillation seems advantageous when gas chromatography is used for simulated distillation. This paper presents results from further research on the separation properties of empty fused silica tubing. The efficiency of this chromatographic system has been examined. The usefulness of such conditions has been studied for simulated distillation, i.e. to determine the boiling-point distribution of complex mixtures, mainly petroleum fractions and products, on the basis of their retention relative to reference substances. The results obtained by use of empty-column gas chromatography (EC-GC) and by use of classical simulated distillation columns have been compared for solutes of different polarity. Studies revealed boiling points determined by EC-GC were more accurate than those obtained by the standard method of simulated distillation.

  12. Improved separation by at-column dilution in preparative hydrophilic interaction chromatography.

    Science.gov (United States)

    Jaffuel, Geoffrey; Chappuis, Laura; Guillarme, Davy; Turlings, Ted C J; Glauser, Gaétan

    2018-01-12

    We evaluated at-column dilution (ACD) as a possible approach to reduce peak distortion caused by the injection of strong solvents in preparative hydrophilic interaction chromatography (HILIC). Three model compounds, namely uridine, cytidine and guanosine were selected and injected either in conventional or ACD conditions, using various proportions of water and acetonitrile in the sample diluent. Plate number and peak capacity were systematically investigated under both isocratic and gradient elution conditions, respectively. In isocratic conditions, ACD was found to provide higher plate numbers with sample diluent containing more than 40% water, but lower plate numbers with injections of less than 40% water, in comparison to a conventional injection system at the preparative scale. These contrasting results were attributed to the fact that i) efficiency was fundamentally reduced in ACD, due to the low make-up flow rate that was used to flush the injection loop, but ii) the trend was reversed for highly aqueous injection thanks to the capacity of ACD to maintain similar efficiency regardless of the injection solvent. On the other hand, peak capacity was comparable between ACD and conventional systems in gradient elution for injections containing low amounts of water. However, ACD became increasingly advantageous as the proportion of water in the injection solvent and/or the injection volume increased. This was confirmed by the separation of a plant root aqueous extract. Altogether, our findings suggest that ACD is beneficial both in isocratic and gradient modes when strongly aqueous solutions are injected, offering an attractive approach to increase loadability, while preserving peak shapes in preparative HILIC. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Purification of Peptide Components including Melittin from Bee Venom using gel filtration chromatography and propionic acid/urea polyacrylamide gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Young Chon Choi

    2006-06-01

    Full Text Available Objectives : This study was conducted to carry out Purification of Melittin and other peptide components from Bee Venom using gel filtration chromatography and propionic acid/urea polyacrylamide gel electrophoresis Methods : Melittin and other peptide components were separated from bee venom by using gel filtration chromatography on Sephadex G-50 column in 0.05M ammonium acetate buffer. Results : Melittin and other peptide components were separated from bee venom by using gel filtration chromatography on Sephadex G-50 column in 0.05M ammonium acetate buffer. The fractions obtained from gel filtration chromatography was analyzed by using SDS-PAGE and propionic acid/urea polyacrylamide gel electrophoresis. The melittin obtained from the gel filtration contained residual amount of phospholipase A2 and a protein with molecular weight of 6,000. The contaminating proteins were removed by the second gel filtration chromatography. Conclusion : Gel filtration chromatography and propionic acid/urea polyacrylamide gel electrophoresis are useful to separate peptide components including melittin from bee venom.

  14. Using the hydrophobic subtraction model to choose orthogonal columns for online comprehensive two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune; Nielsen, Nikoline Juul; Christensen, Jan H.

    2014-01-01

    A method for choosing orthogonal columns for a specific sample set in on-line comprehensive two-dimensional liquid chromatography (LC×LC) was developed on the basis of the hydrophobic subtraction model. The method takes into account the properties of the sample analytes by estimating new F......-weights for the prediction of orthogonality. We compared sets of F-weights and used these F-weights to predict orthogonal column combinations: (1) the standard F-weights determined by Gilroy et al. [1], (2) F-weights determined from the retention of sample analytes, and the same procedure of calculation as described...... neutral and 4 acidic oxygenated polycyclic aromatic compounds (PACs) and 3 nitrogen-containing PAC bases was measured isocratically on 12 columns. The isocratic runs were used to determine the hydrophobic subtraction model analyte parameters, and these were used to estimate new F-weights and predict...

  15. Determination of sulfite in dried garlic by reversed-phase ion-pairing liquid chromatography with post-column detection.

    Science.gov (United States)

    Perfetti, Gracia A; Diachenko, Gregory W

    2003-01-01

    A method is described for determining sulfite in dried garlic. Garlic is extracted with an HCl solution to inhibit the formation of allicin, which interferes with the determination of sulfite. After cleanup of the extract on a C18 solid-phase extraction column, sulfite is converted to hydroxymethylsulfonate (HMS) by adding formaldehyde and heating to 50 degrees C. HMS is determined by reversed-phase ion-pairing liquid chromatography with post-column detection. The post-column reaction system consists of the addition of KOH to convert HMS to sulfite ion, followed by the addition of 5,5'-dithiobis(2-nitrobenzoic acid) to produce 5-mercapto-2-nitrobenzoic acid which is detected spectrophotometrically at 450 nm. Background levels in unsulfited dried garlic equivalent to method for determining sulfite in garlic is discussed.

  16. Highly sensitive determination of 2,4,6-trinitrotoluene and related byproducts using a diol functionalized column for high performance liquid chromatography.

    Directory of Open Access Journals (Sweden)

    Burcu Gumuscu

    Full Text Available In this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT; 2,4-dinitrotoluene (2,4-DNT; 2,6-dinitrotoluene (2,6-DNT; 2-aminodinitrotoluene (2-ADNT and 4-aminodinitrotoluene (4-ADNT molecules in high-performance liquid-chromatography (HPLC with UV sensor has been developed using diol column. This approach improves on cost, time, and sensitivity over the existing methods, providing a simple and effective alternative. Total analysis time was less than 13 minutes including column re-equilibration between runs, in which water and acetonitrile were used as gradient elution solvents. Under optimized conditions, the minimum resolution between 2,4-DNT and 2,6-DNT peaks was 2.06. The recovery rates for spiked environmental samples were between 95-98%. The detection limits for diol column ranged from 0.78 to 1.17 µg/L for TNT and its byproducts. While the solvent consumption was 26.4 mL/min for two-phase EPA and 30 mL/min for EPA 8330 methods, it was only 8.8 mL/min for diol column. The resolution was improved up to 49% respect to two-phase EPA and EPA 8330 methods. When compared to C-18 and phenyl-3 columns, solvent usage was reduced up to 64% using diol column and resolution was enhanced approximately two-fold. The sensitivity of diol column was afforded by the hydroxyl groups on polyol layer, joining the formation of charge-transfer complexes with nitroaromatic compounds according to acceptor-donor interactions. Having compliance with current requirements, the proposed method demonstrates sensitive and robust separation.

  17. Chromatography

    Science.gov (United States)

    ... that are bonded together. For example, water is a chemical bond of oxygen and hydrogen. Proteins are another type of chemical compound. There are different kinds of chromatography. These include gas, high pressure liquid, or ion ...

  18. Fingerprinting of traditional Chinese medicines on the C18-Diol mixed-mode column in online or offline two-dimensional liquid chromatography on the single column modes.

    Science.gov (United States)

    Wang, Qing; Tong, Ling; Yao, Lin; Zhang, Peng; Xu, Li

    2016-06-05

    In the present study, a mixed-mode stationary phase, C18-Diol, was applied for fingerprint analysis of traditional Chinese medicines. Hydrophobic, hydrogen bonding and electrostatic interactions were demonstrated to contribute the retention separately or jointly, which endowed the C18-Diol stationary phase with distinct selectivity compared to the bare C18 one. The separation of total alkaloids extracted from Fritillaria hupehensis was compared on the C18-Diol and conventional C18 column with the greater resolving power and better symmetry responses on the former one. Besides, a novel two-dimensional liquid chromatography on the single column (2D-LC-1C) was realized on C18-Diol with the offline mode for the alcohol extract of Fritillaria hupehensis and online mode for Ligusticum chuanxiong Hort. The early co-eluted extracted components with great polarity on the first dimension were reinjected on the same column and well separated on the second dimension. The results exhibited that the two complementary RPLC and HILIC modes on C18-Diol stationary phase enhanced the separation capacity and revealed more abundant chemical information of the sample, which was a powerful tool in analyzing complex herbal medicines. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Hydrodynamic impact of particle shape in slurry packed liquid chromatography columns

    DEFF Research Database (Denmark)

    Lottes, F.; Arlt, W.; Minceva, M.

    2009-01-01

    for visualization of the inner part of a packed column and measurement of the spatial resolved column packing properties. For evaluation of the influence of the particle shape on the velocity distribution and column performance, irregular and spherical reversed phases were studied in detail. The results showed......We report on a series of flow velocity and efficiency profiles, which were measured across the cross section of preparative chromatographic columns packed with different stationary phase materials using computed tomography. It is shown that this non-invasive technique is very useful...... a decreasing velocity towards the column wall most certainly due to a lower permeability. This effect was much less pronounced in the case of spherical particles, indicating a more homogenous packing structure. The influence of the column packing pressure, as a possible measure for improvement of the packing...

  20. Column selectivity in reversed-phase liquid chromatography I. A general quantitative relationship.

    Science.gov (United States)

    Wilson, N S; Nelson, M D; Dolan, J W; Snyder, L R; Wolcott, R G; Carr, P W

    2002-07-05

    Retention factors k have been measured for 67 neutral, acidic and basic solutes of highly diverse molecular structure (size, shape, polarity, hydrogen bonding, pKa, etc.) on 10 different C18 columns (other conditions constant). These data have been combined with k values from a previous study (86 solutes, five different C8 and C18 columns) to develop a six-term equation for the correlation of retention as a function of solute and column. Values of k can be correlated with an accuracy of +/- 1-2% (1 standard deviation). This suggests that all significant contributions to column selectivity have been identified (and can be measured) for individual alkyl-silica columns which do not have an embedded polar group. That is, columns of the latter kind can be quantitatively characterized in terms of selectivity for use in the separation of any sample.

  1. Band broadening in fast gradient high-performance liquid chromatography: application to the second generation of 4.6 mm I.D. silica monolithic columns.

    Science.gov (United States)

    Gritti, Fabrice; Guiochon, Georges

    2012-05-18

    The sources of band broadening in fast gradient elution chromatography include the contributions of the tubings placed upstream the column, the isocratic migration of the sample that takes place in the column until the moment when the front of the gradient catches up with it, dispersion and mass transfer resistance during band migration under gradient elution to the column outlet, and dispersion in the tubings downstream the column to the detector. The measurements of all these contributions is meticulously described, analyzed, and applied to assess the kinetic performance of monolithic columns of the second generation (KGaA Merck) in gradient elution, at the highest possible speed at which they can be operated (t(0)=25s at P=200 bar). These results are compared to those provided by several 4.6mm × 100mm columns packed with sub-3 μm core-shell particles (Kinetex, Phenomenex and Halo, Advanced Material Technologies) and by a 2.1mm × 100mm column packed with fully porous 1.7 μm BEH particles (Waters). A RPLC checkout sample (Agilent) containing nine alkanophenones (molecular weights between 120 and 204 g/mol) was used for this purpose. The mobile phase was a mixture of acetonitrile and water and the instrument, an optimized version of the 1290 Infinity HPLC system (Agilent). The results show that the overall peak capacity provided by this second generation of monolithic columns is nearly 30% smaller than that provided by commercial columns packed with sub-3 μm core-shell particles and 20% smaller than that provided by a narrow-bore column packed with sub-2 μm fully porous particles. After isolating the sole band broadening contribution due to the gradient migration of the analytes along the columns, the BEH column proved to provide the highest resolution power (apparent average plate height, of 2 μm), followed by the 2.6 μm Kinetex particles (3.0 μm), the Halo particles (3.2 μm), and the second generation of 4.6mm I.D. monolithic columns (6.5 μm). This

  2. Advances in organic polymer-based monolithic column technology for high-resolution liquid chromatography-mass spectrometry profiling of antibodies, intact proteins, oligonucleotides, and peptides.

    Science.gov (United States)

    Eeltink, Sebastiaan; Wouters, Sam; Dores-Sousa, José Luís; Svec, Frantisek

    2017-05-19

    This review focuses on the preparation of organic polymer-based monolithic stationary phases and their application in the separation of biomolecules, including antibodies, intact proteins and protein isoforms, oligonucleotides, and protein digests. Column and material properties, and the optimization of the macropore structure towards kinetic performance are also discussed. State-of-the-art liquid chromatography-mass spectrometry biomolecule separations are reviewed and practical aspects such as ion-pairing agent selection and carryover are presented. Finally, advances in comprehensive two-dimensional LC separations using monolithic columns, in particular ion-exchange×reversed-phase and reversed-phase×reversed-phase LC separations conducted at high and low pH, are shown. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Tuning preparation conditions towards optimized separation performance of thermally polymerized organo-silica monolithic columns in capillary liquid chromatography.

    Science.gov (United States)

    Gharbharan, Deepa; Britsch, Denae; Soto, Gabriela; Weed, Anna-Marie Karen; Svec, Frantisek; Zajickova, Zuzana

    2015-08-21

    Tuning of preparation conditions, such as variations in the amount of a porogen, concentration of an aqueous acid catalyst, and adjustment in polymerization temperature and time, towards optimized chromatographic performance of thermally polymerized monolithic capillaries prepared from 3-(methacryloyloxy)propyltrimethoxysilane has been carried out. Performance of capillary columns in reversed-phase liquid chromatography was assessed utilizing various sets of solutes. Results describing hydrophobicity, steric selectivity, and extent of hydrogen bonding enabled comparison of performance of hybrid monolithic columns prepared under thermal (TSG) and photopolymerized (PSG) conditions. Reduced amounts of porogen in the polymerization mixture, and prolonged reaction times were necessary for the preparation of monolithic columns with enhanced retention and column efficiency that reached to 111,000 plates/m for alkylbenzenes with shorter alkyl chains. Both increased concentration of catalyst and higher temperature resulted in faster polymerization but inevitably in insufficient time for pore formation. Thermally polymerized monoliths produced surfaces, which were slightly more hydrophobic (a methylene selectivity of 1.28±0.002 TSG vs 1.20±0.002 PSG), with reduced number of residual silanols (a caffeine/phenol selectivity of 0.13±0.001 TSG vs 0.17±0.003 PSG). However, steric selectivity of 1.70±0.01 was the same for both types of columns. The batch-to-batch repeatability was better using thermal initiation compared to monolithic columns prepared under photopolymerized conditions. RSD for retention factor of benzene was 3.7% for TSG capillaries (n=42) vs. 6.6% for PSG capillaries (n=18). A similar trend was observed for columns prepared within the same batch. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Accurate measurements of infinite dilution activity coefficients using gas chromatography with static-wall-coated open-tubular columns.

    Science.gov (United States)

    Xu, Qianqian; Su, Baogen; Luo, Xinyi; Xing, Huabin; Bao, Zongbi; Yang, Qiwei; Yang, Yiwen; Ren, Qilong

    2012-11-06

    Wall-coated open-tubular (WCOT) columns provide higher column efficiency and lower solute interfacial adsorption effect than packed columns. However, previous efforts used to measure the infinite dilution activity coefficient (γ(∞)) via a chromatographic technique have used packed columns, because the low carrier gas flow rate (U) and the small stationary phase amount (n(2)) in WCOT columns raise large errors. By rationally revising the γ(∞)-calculation equation for static-wall-coated open-tubular column, we observed that U and n(2) are not necessarily needed and the resulting error could be reduced, and WCOT column gas chromatography subsequently became a superior method for the accurate γ(∞) determination. In this study, we validate our revised γ(∞)-calculation equation by measuring γ(∞) in an ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate system, in which 55 organic compounds covering a wide range of functional groups were used as probe solutes and their γ(∞) values in the ionic liquid were determined at 40.0, 50.0, and 60.0 °C. Experimental error analysis shows that our revised equation remarkably reduces the error compared to the common γ(∞)-calculation equation. Our data is consistent with previously reported values obtained via other techniques, which further proves the credibility of our revised equation. The accurately determined γ(∞) values can be directly used to calculate the partial molar excess enthalpy, selectivity, and capacity, which will benefit for the rapid screening of solvents (especially ionic liquids) in separation approaches.

  5. Organic solvent modifier and temperature effects in non-aqueous size-exclusion chromatography on reversed-phase columns.

    Science.gov (United States)

    Caltabiano, Anna M; Foley, Joe P; Striegel, André M

    2018-01-05

    Common reversed-phase columns (C 18 , C 4 , phenyl, and cyano) offer inert surfaces suitable for the analysis of polymers by size-exclusion chromatography (SEC). The effect of tetrahydrofuran (THF) solvent and the mixtures of THF with a variety of common solvents used in high performance liquid chromatography (acetonitrile, methanol, dimethylformamide, 2-propanol, ethanol, acetone and chloroform) on reversed-phase stationary phase characteristics relevant to size exclusion were studied. The effect of solvent on the elution of polystyrene (PS) and poly(methyl methacrylate) (PMMA) and the effect of column temperature (within a relatively narrow range corresponding to typical chromatographic conditions, i.e., 10°C-60°C) on the SEC partition coefficients K SEC of PS and PMMA polymers, were also investigated. The bonded phases show remarkable differences in size separations when binary mixtures of THF with other solvents are used as the mobile phase. The solvent impact can be two-fold: (i) change of the polymeric coil size, and possible shape, and (ii) change of the stationary phase pore volume. If the effect of this impact is properly moderated, then the greatest benefit of optimized solute resolution can be achieved. Additionally, this work provides an insight on solvent-stationary phase interactions and their effects on column pore volume. The only effect of temperature observed in our studies was a decreased elution volume of the polymers with increasing temperature. SEC partition coefficients were temperature-independent in the range of 10°C-60°C and therefore, over this temperature range elution of PS and PMMA polymers is by near-ideal SEC on reversed-phase columns. Non-ideal SEC appears to occur for high molar mass PMMA polymers on a cyano column when alcohols are used as mobile phase modifiers. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Effects of a malfunctional column on conventional and FeedCol-simulated moving bed chromatography performance.

    Science.gov (United States)

    Song, Ji-Yeon; Oh, Donghoon; Lee, Chang-Ha

    2015-07-17

    The effects of a malfunctional column on the performance of a simulated moving bed (SMB) process were studied experimentally and theoretically. The experimental results of conventional four-zone SMB (2-2-2-2 configuration) and FeedCol operation (2-2-2-2 configuration with one feed column) with one malfunctional column were compared with simulation results of the corresponding SMB processes with a normal column configuration. The malfunctional column in SMB processes significantly deteriorated raffinate purity. However, the extract purity was equivalent or slightly improved compared with the corresponding normal SMB operation because the complete separation zone of the malfunctional column moved to a lower flow rate range in zones II and III. With the malfunctional column configuration, FeedCol operation gave better experimental performance (up to 7%) than conventional SMB operation because controlling product purity with FeedCol operation was more flexible through the use of two additional operating variables, injection time and injection length. Thus, compared with conventional SMB separation, extract with equivalent or slightly better purity could be produced from FeedCol operation even with a malfunctional column, while minimizing the decrease in raffinate purity (less than 2%). Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Overloading study of basic compounds with a positively charged C18 column in liquid chromatography.

    Science.gov (United States)

    Wang, Chaoran; Guo, Zhimou; Long, Zhen; Zhang, Xiuli; Liang, Xinmiao

    2013-03-15

    While tailing and overloading of basic compounds remain problematic on most RP columns, a new kind of positively charged RP column named XCharge C18 was found to be superior good for the separation of alkaloids in our practical use. In this work, the surface charge property of the XCharge C18 column was evaluated by the retention of NO(3)(-) under different pH values and buffer concentrations. A considerable and pH-dependent positive charge was confirmed on the column. Then overloading behaviors of bases were systematically studied using amitriptyline as a basic probe. Good peak shapes (TfC18 column to achieve the good performance for bases, which could be explained by the multiple-site adsorption theory as ionic repulsion would shield the solute from occupying high-energy sites deeper in C18 layer. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Capillary column switching restricted-access media-liquid chromatography-electrospray ionization-tandem mass spectrometry system for simultaneous and direct analysis of drugs in biofluids.

    Science.gov (United States)

    Santos-Neto, Alvaro J; Markides, Karin E; Sjöberg, Per J R; Bergquist, Jonas; Lancas, Fernando M

    2007-08-15

    Capillary online restricted-access media-liquid chromatography-electrospray ionization-tandem mass spectrometry (RAM-LC-ESI-MS/MS) for direct analysis of drugs and metabolites spiked in biological fluids was developed. Using a column switching setup it was possible to perform effective sample preparation and analysis of raw biological fluids (plasma and urine) without matrix effects in the electrospray mass spectrometric detection step. The peak focusing efficiency of the extraction column was more effective in backflush compared to foreflush mode. The system was able to concentrate diminished samples of polar drugs and their metabolites reaching quantifiable results as low as 1 ng/mL utilizing a sample volume of only 333 nL of biofluids. New column hardware was developed to circumvent clogging problems experienced with plasma injections. The glass fiber filter frit, which is commonly used, was replaced with a short piece of 20 microm i.d. fused silica capillary. The extraction columns were able to handle up to 60 injections and showed a high loading capacity, making the saturation of the MS detector the limiting factor on the linear dynamic range. The simultaneous separation and detection of 10 drugs and metabolites was obtained in 8 min of analysis, including the online sample preparation and enrichment step.

  9. Sequential injection chromatography with post-column reaction/derivatization for the determination of transition metal cations in natural water samples.

    Science.gov (United States)

    Horstkotte, Burkhard; Jarošová, Patrícia; Chocholouš, Petr; Sklenářová, Hana; Solich, Petr

    2015-05-01

    In this work, the applicability of Sequential Injection Chromatography for the determination of transition metals in water is evaluated for the separation of copper(II), zinc(II), and iron(II) cations. Separations were performed using a Dionex IonPAC™ guard column (50mm×2mm i.d., 9 µm). Mobile phase composition and post-column reaction were optimized by modified SIMPLEX method with subsequent study of the concentration of each component. The mobile phase consisted of 2,6-pyridinedicarboxylic acid as analyte-selective compound, sodium sulfate, and formic acid/sodium formate buffer. Post-column addition of 4-(2-pyridylazo)resorcinol was carried out for spectrophotometric detection of the analytes׳ complexes at 530nm. Approaches to achieve higher robustness, baseline stability, and detection sensitivity by on-column stacking of the analytes and initial gradient implementation as well as air-cushion pressure damping for post-column reagent addition were studied. The method allowed the rapid separation of copper(II), zinc(II), and iron(II) within 6.5min including pump refilling and aspiration of sample and 1mmol HNO3 for analyte stacking on the separation column. High sensitivity was achieved applying an injection volume of up to 90µL. A signal repeatability of<2% RSD of peak height was found. Analyte recovery evaluated by spiking of different natural water samples was well suited for routine analysis with sub-micromolar limits of detection. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Displacement chromatography of proteins using a retained pH front in a hydrophobic charge induction chromatography column.

    Science.gov (United States)

    Pinto, N D S; Frey, Douglas D

    2015-03-27

    The chromatographic separation of two proteins into a displacement train of two adjoined rectangular bands was accomplished using a novel method for hydrophobic charge induction chromatography (HCIC) which employs a self-sharpening pH front as the displacer. This method exploits the fact that protein elution in HCIC is promoted by a pH change, but is relatively independent of salt effects, so that a retained pH front can be used in place of a traditional displacer in displacement chromatography. The retained pH front was produced using the two adsorbed buffering species tricine and acetic acid. The separation of lysozyme and α-chymotrypsinogen A into adjoined, rectangular bands was accomplished with overall recoveries based on the total mass injected greater than 90 and 70%, respectively. The addition of urea to the buffer system increased the sharpness of the pH front by 36% while the yields of lysozyme and α-chymotrypsinogen A based on the total mass eluted increased from 76% to 99% and from 37% to 85%, respectively, when the purities of both proteins in their product fractions were fixed at 85%. The results demonstrate that the method developed in this study is a useful variant of HCIC and is also a useful alternative to other displacement chromatography methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. The fractionation of dinucleoside monophosphate and some trinucleoside diphosphate isonicotinoyl hydrazones by column chromatography

    Science.gov (United States)

    Hunt, John A.

    1970-01-01

    A column-chromatographic system using DEAE-cellulose and gradient elution with triethylammonium formate at pH4.0–3.5 is described. It is capable of separating the oligonucleotide isonicotinoyl hydrazones that are produced by nuclease digestion of RNA oxidized with periodate and coupled with isonicotinic acid hydrazide. Fifteen dinucleoside monophosphate isonicotinoyl hydrazones were characterized by their elution positions on the columns, so that all but two of them could readily be identified. Twelve trinucleoside diphosphate hydrazones were also characterized by their elution positions on the column. The application of this method of fractionation to terminal-sequence studies of RNA is discussed. PMID:5414095

  12. Rapid determination of Papaver somniferum alkaloids in process streams using monolithic column high-performance liquid chromatography with chemiluminescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Costin, Jason W. [School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3217 (Australia); Lewis, Simon W. [Department of Applied Chemistry, Curtin University of Technology, Perth, WA 6845 (Australia); Purcell, Stuart D. [GlaxoSmithKline, Port Fairy, Victoria 3284 (Australia); Waddell, Lucy R. [GlaxoSmithKline, Port Fairy, Victoria 3284 (Australia); Francis, Paul S. [School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3217 (Australia); Barnett, Neil W. [School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3217 (Australia)]. E-mail: barnie@deakin.edu.au

    2007-07-30

    We have combined high-performance liquid chromatography (HPLC) separations using a monolithic column with acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection in a rapid and highly sensitive method to monitor the process of extracting opiate alkaloids from Papaver somniferum. Due to the high flow rates allowed with the monolithic column and the inherent selectivity of the chemiluminescence reactions, the four predominant alkaloids - morphine, codeine, oripavine and thebaine - were determined in less than 2 min. The results obtained with numerous process samples compared favourable with those of the standard HPLC methodology. Limits of detection were 1 x 10{sup -10} M, 5 x 10{sup -10} M, 5 x 10{sup -10} M and 1 x 10{sup -9} M, for morphine, codeine, oripavine and thebaine, respectively.

  13. Simple determination of betaine, l-carnitine and choline in human urine using self-packed column and column-switching ion chromatography with nonsuppressed conductivity detection.

    Science.gov (United States)

    Wei, Dan; Zhu, Yan; Guo, Ming

    2018-02-01

    A sequential online extraction, clean-up and separation system for the determination of betaine, l-carnitine and choline in human urine using column-switching ion chromatography with nonsuppressed conductivity detection was developed in this work. A self-packed pretreatment column (50 × 4.6 mm, i.d.) was used for the extraction and clean-up of betaine, l-carnitine and choline. The separation was achieved using self-packed cationic exchange column (150 × 4.6 mm, i.d.), followed by nonsuppressed conductivity detection. Under optimized experimental conditions, the developed method presented good analytical performance, with excellent linearity in the range of 0.60-100 μg mL -1 for betaine, 0.75-100 μg mL -1 for l-carnitine and 0.50-100 μg mL -1 for choline, with all correlation coefficients (R 2 ) >0.99 in urine. The limits of detection were 0.15 μg mL -1 for betaine, 0.20 μg mL -1 for l-carnitine and 0.09 μg mL -1 for choline. The intra- and inter-day accuracy and precision for all quality controls were within ±10.32 and ±9.05%, respectively. Satisfactory recovery was observed between 92.8 and 102.0%. The validated method was successfully applied to the detection of urinary samples from 10 healthy people. The values detected in human urine using the proposed method showed good agreement with the measurement reported previously. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Supercritical Fluid Chromatography of Drugs: Parallel Factor Analysis for Column Testing in a Wide Range of Operational Conditions

    Science.gov (United States)

    Al-Degs, Yahya; Andri, Bertyl; Thiébaut, Didier; Vial, Jérôme

    2017-01-01

    Retention mechanisms involved in supercritical fluid chromatography (SFC) are influenced by interdependent parameters (temperature, pressure, chemistry of the mobile phase, and nature of the stationary phase), a complexity which makes the selection of a proper stationary phase for a given separation a challenging step. For the first time in SFC studies, Parallel Factor Analysis (PARAFAC) was employed to evaluate the chromatographic behavior of eight different stationary phases in a wide range of chromatographic conditions (temperature, pressure, and gradient elution composition). Design of Experiment was used to optimize experiments involving 14 pharmaceutical compounds present in biological and/or environmental samples and with dissimilar physicochemical properties. The results showed the superiority of PARAFAC for the analysis of the three-way (column × drug × condition) data array over unfolding the multiway array to matrices and performing several classical principal component analyses. Thanks to the PARAFAC components, similarity in columns' function, chromatographic trend of drugs, and correlation between separation conditions could be simply depicted: columns were grouped according to their H-bonding forces, while gradient composition was dominating for condition classification. Also, the number of drugs could be efficiently reduced for columns classification as some of them exhibited a similar behavior, as shown by hierarchical clustering based on PARAFAC components. PMID:28695040

  15. Ion-Exclusion High-Performance Liquid Chromatography of Aliphatic Organic Acids Using a Surfactant-Modified C18 Column.

    Science.gov (United States)

    Fasciano, Jennifer M; Mansour, Fotouh R; Danielson, Neil D

    2016-07-01

    Ion exclusion chromatography (IELC) of short chain aliphatic carboxylic acids is normally done using a cation exchange column under standard HPLC conditions but not in the ultra-HPLC (UHPLC) mode. A novel IELC method for the separation of this class of carboxylic acids by either HPLC or UHPLC utilizing a C18 column dynamically modified with sodium dodecyl sulfate has been developed. The sample capacity is estimated to be near 10 mM for a 20 µL injection or 0.2 µmol using a 150 × 4.6 mm column. The optimum mobile phase determined for three standard mixtures of organic acids is 1.84 mM sulfuric acid at pH 2.43 and a flow rate of 0.6 mL/min. Under optimized conditions, a HPLC separation of four aliphatic carboxylic acids such as tartaric, malonic, lactic and acetic can be achieved in under 4 min and in C18 column can be easily extended when needed to IELC under either standard or UHPLC conditions. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Activity behavior of a HPLC column including α-chymotrypsin immobilized monosized-porous particles

    International Nuclear Information System (INIS)

    Bilici, Z.; Camli, S.T.; Unsal, E.; Tuncel, A.

    2004-01-01

    In this study, a polymer-based, α-chymotrypsin (CT) immobilized HPLC column was prepared as a potential material for affinity-HPLC and chiral separation applications. Monosized-macroporous particles were synthesized as the support material by a relatively new polymerization protocol, the so-called, 'modified seeded polymerization'. The particles were obtained in the form of styrene-glycidyl methacrylate- divinylbenzene terpolymer approximately 11 μm in size. The particles were treated with aqueous ammonia to have primary amine groups on the porous surface. The amine functionalized particles were reacted by glutaraldehyde and the enzyme, CT, was covalently attached. CT carrying monosized-porous particles were slurry packed into the HPLC column 50 mmx4.6 mm in size. Since the activity behavior of immobilized CT played an important role in the enantiomeric separations performed by similar columns, the enzymatic activity behavior of the column produced by our protocol was determined. For this purpose, HPLC column was used as a packed bed reactor and the enzymatic reaction was continuously followed by measuring the absorbance of the output flow by the UV-detector of HPLC. S-shaped absorbance-time curves were obtained by monitoring the reactor output both in dynamic and steady-state periods. The columns with relatively lower immobilized enzyme content were more sensitive to the changes in the operating conditions and responded with more appreciable substrate conversion changes. The maximum reaction rate of the immobilized enzyme was estimated as approximately 25% of the free one by the mathematical model describing the activity behavior of the column. No significant loss was observed in the activity of the immobilized enzyme during the course of the experiments

  17. Detection of radiation-induced hydrocarbons in Camembert irradiated before and after the maturing process-comparison of florisil column chromatography and on-line coupled liquid chromatography-gas chromatography

    International Nuclear Information System (INIS)

    Schulzki, G.; Spiegelberg, A.; Bögl, K.W.; Schreiber, G.A.

    1995-01-01

    The influence of the maturing process on the detection of radiation-induced volatile hydrocarbons in the fat of Camembert has been investigated. Two analytical methods for separation of the hydrocarbon fraction from the lipid were applied: Florisil column chromatography with subsequent gas chromatographic-mass spectrometric (GC-MS) determination as well as on-line coupled liquid chromatography-GC-MS. The maturing process had no influence on the detection of radiation-induced volatiles. Comparable results were achieved with both analytical methods. However, preference is given to the more effective on-line coupled LC-GC method

  18. Separation of beta-human chorionic gonadotropin and immunoglobulin G by a miniaturized size exclusion chromatography column

    Science.gov (United States)

    Yang, Yongmo; Chae, Junseok

    2009-04-01

    This report describes a miniaturized size exclusion chromatography column that effectively preseparates raw samples for medical point-of-care testing (POCT) devices. The minicolumn is constructed of polydimethylsiloxane fabricated on a glass slide. The minicolumn separates 300 ng/ml of beta-human chorionic gonadotropin (β-hCG) from an immunoglobulin G (IgG)-rich solution (100 μg/ml) in 7.7 min, with 2.23 resolution and 0.018 mm plate height. The complete analyte discrimination shows potential for the sample preparation stage of POCT devices for cancer screening, prognosis, and monitoring.

  19. Gas-liquid chromatography of bacterial fatty acids with a fused-silica capillary column.

    OpenAIRE

    Moss, C W; Dees, S B; Guerrant, G O

    1980-01-01

    The use of flexible, fused-silica capillary column for gas-liquid chromatographic analysis of bacterial fatty acids is illustrated with Propionibacterium acnes, Propionibacterium shermanii, and a standard methyl ester mixture.

  20. Determination of trace lanthanide impurities in nuclear grade uranium by coupled-column liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Lucy, C.A.; Gureli, L.; Elchuk, S. (Chalk River Lab., Ontario (Canada))

    1993-11-15

    Impurities such as Sm, Gd, Eu, and Dy will degrade the neutron economy of a nuclear reactor when present even at sub-parts-per-million levels, as a result of their high neutron absorption cross sections. Conventional determinations of lanthanide impurities in uranium require 0.5-100 g of uranium. A coupled-column chromatographic procedure has been developed which dramatically reduces the quantity of uranium required. The first column, a semipreparative reversed-phase column, removes the uranium matrix, while the second column, an analytical-scale cation exchange column, concentrates and separates the lanthanides prior to their postcolumn reaction detection with arsenazo III. The maximum loading of uranium onto the reversed-phase column is determined by the volume overload of the lanthanides rather than the concentration overload of the uranium. Using 20 mg of uranium, a detection limit of 0.02 [mu]g/g of U is achieved for Sm, Gd, Eu, and Dy with no interference from transition or alkaline earth metals present in the uranium. 39 refs., 5 figs., 2 tabs.

  1. Affinity-based screening of combinatorial libraries using automated, serial-column chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Evans, D.M.; Williams, K.P.; McGuinness, B. [PerSeptive Biosystems, Framingham, MA (United States)] [and others

    1996-04-01

    The authors have developed an automated serial chromatographic technique for screening a library of compounds based upon their relative affinity for a target molecule. A {open_quotes}target{close_quotes} column containing the immobilized target molecule is set in tandem with a reversed-phase column. A combinatorial peptide library is injected onto the target column. The target-bound peptides are eluted from the first column and transferred automatically to the reversed-phase column. The target-specific peptide peaks from the reversed-phase column are identified and sequenced. Using a monoclonal antibody (3E-7) against {beta}-endorphin as a target, we selected a single peptide with sequence YGGFL from approximately 5800 peptides present in a combinatorial library. We demonstrated the applicability of the technology towards selection of peptides with predetermined affinity for bacterial lipopolysaccharide (LPS, endotoxin). We expect that this technology will have broad applications for high throughput screening of chemical libraries or natural product extracts. 21 refs., 4 figs.

  2. The Binding of Biotin to Sepharose-Avidin Column: Demonstration of the Affinity Chromatography Technique

    Science.gov (United States)

    Landman, A. D.; Landman, N. N.

    1976-01-01

    Describes a biochemistry experiment that illustrates the methodology of affinity chromatography by attaching avidin, a glycoprotein in egg white, to a Sepharose matrix in order to bind biotin-containing proteins. (MLH)

  3. Application of liquid column chromatography to preconcentration, separation and determination of platinum metals

    International Nuclear Information System (INIS)

    Alimarin, I.P.; Basova, E.M.; Bol'shova, T.A.; Ivanov, V.M.

    1986-01-01

    Separation and determination of platimum metals using the methods of adsorption, ion-pair, ion-exchange, distributing and sieve chromatography are discussed in the review of literature in 1971-1984. Separation and determination of metals as chelates using the method of adsorption and ion-pair chromatograpy are noted to be most perspective directions of developing highly effective liquid chromatography of inorganic systems

  4. CHROMATOGRAPHY OF BLOOD-CLOTTING FACTORS AND SERUM PROTEINS ON COLUMNS OF DIATOMACEOUS EARTH

    Science.gov (United States)

    Milstone, J. H.

    1955-01-01

    1. In batch adsorptions with prothrombin solutions, hyflo was the weakest adsorbent, standard super-cel intermediate, and filter-cel strongest. Of these three grades of diatomaceous earth, hyflo has the smallest surface area per gram and filter-cel the largest. In parallel breakthrough experiments, a column of standard super-cel had a capacity almost six times that of a hyflo column. 2. After partial removal of impurities by diatomaceous earth, prothrombin preparations contained less thrombokinase, were more stable, and displayed less tendency to form thrombin "spontaneously." Thrombokinase (or its precursor) was removed from a preparation of prothrombin by passage through a filter cake of standard super-cel. The specific activity of the prothrombin was increased; and 62 per cent of the activity was recovered. 3. Prothrombin was adsorbed from an ammonium sulfate solution at pH 5.26 by columns of hyflo or standard super-cel. When eluted by phosphate solutions, the protein moved down the columns more readily at higher pH and higher concentration of phosphate salts, within the pH range 5.0 to 6.6, and within the phosphate range 0.1 to 1.0 M. 4. Thrombin was adsorbed on a column of standard super-cel at pH 5.11. As successive eluents passed through the column, the thrombin emerged between two bands of impurities. The specific activity of the thrombin was raised; and 83 per cent of the activity was recovered. 5. With a column of standard super-cel, and with a series of eluents within the pH range 5.1 to 6.3, total serum proteins were separated into four major bands. About 94 per cent of the protein was recovered. PMID:13242761

  5. Phytochemical analysis of ethanolic extract of Dichrostachys Cinerea W and Arn leaves by a thin layer chromatography, high performance thin layer chromatography and column chromatography

    OpenAIRE

    M Vijayalakshmi; K Periyanayagam; K Kavitha; K Akilandeshwari

    2013-01-01

    Background: The leaves of Dichrostachys cinerea are used as laxative, diuretic, painkiller. It is also used in the treatment of gonorrhoea, boils, oedema, gout, veneral diseases and nasopharyngeal affections, etc. Materials and Methods: The Phytochemical investigation of ethanolic extract of D. cinerea leaves were performed by standard chemical tests, thin layer chromatography (TLC) by using various solvent systems, and by high performance liquid chromatography (HPTLC). Two compounds were...

  6. Bed morphological features associated with an optimal slurry concentration for reproducible preparation of efficient capillary ultrahigh pressure liquid chromatography columns.

    Science.gov (United States)

    Reising, Arved E; Godinho, Justin M; Jorgenson, James W; Tallarek, Ulrich

    2017-06-30

    Column wall effects and the formation of larger voids in the bed during column packing are factors limiting the achievement of highly efficient columns. Systematic variation of packing conditions, combined with three-dimensional bed reconstruction and detailed morphological analysis of column beds, provide valuable insights into the packing process. Here, we study a set of sixteen 75μm i.d. fused-silica capillary columns packed with 1.9μm, C18-modified, bridged-ethyl hybrid silica particles slurried in acetone to concentrations ranging from 5 to 200mg/mL. Bed reconstructions for three of these columns (representing low, optimal, and high slurry concentrations), based on confocal laser scanning microscopy, reveal morphological features associated with the implemented slurry concentration, that lead to differences in column efficiency. At a low slurry concentration, the bed microstructure includes systematic radial heterogeneities such as particle size-segregation and local deviations from bulk packing density near the wall. These effects are suppressed (or at least reduced) with higher slurry concentrations. Concomitantly, larger voids (relative to the mean particle diameter) begin to form in the packing and increase in size and number with the slurry concentration. The most efficient columns are packed at slurry concentrations that balance these counteracting effects. Videos are taken at low and high slurry concentration to elucidate the bed formation process. At low slurry concentrations, particles arrive and settle individually, allowing for rearrangements. At high slurry concentrations, they arrive and pack as large patches (reflecting particle aggregation in the slurry). These processes are discussed with respect to column packing, chromatographic performance, and bed microstructure to help reinforce general trends previously described. Conclusions based on this comprehensive analysis guide us towards further improvement of the packing process. Copyright

  7. 3D printed titanium micro-bore columns containing polymer monoliths for reversed-phase liquid chromatography.

    Science.gov (United States)

    Gupta, Vipul; Talebi, Mohammad; Deverell, Jeremy; Sandron, Sara; Nesterenko, Pavel N; Heery, Brendan; Thompson, Fletcher; Beirne, Stephen; Wallace, Gordon G; Paull, Brett

    2016-03-03

    The potential of 3D selective laser melting (SLM) technology to produce compact, temperature and pressure stable titanium alloy chromatographic columns is explored. A micro bore channel (0.9 mm I.D. × 600 mm long) was produced within a 5 × 30 × 30 mm titanium alloy (Ti-6Al-4V) cuboid, in form of a double handed spiral. A poly(butyl methacrylate-co-ethyleneglycoldimethacrylate) (BuMA-co-EDMA) monolithic stationary phase was thermally polymerised within the channel for application in reversed-phase high-performance liquid chromatography. The prepared monolithic column was applied to the liquid chromatographic separation of intact proteins and peptides. Peak capacities of 69-76 (for 6-8 proteins respectively) were observed during isothermal separation of proteins at 44 °C which were further increased to 73-77 using a thermal step gradient with programmed temperature from 60 °C to 35 °C using an in-house built direct-contact heater/cooler platform based upon matching sized Peltier thermoelectric modules. Rapid temperature gradients were possible due to direct-contact between the planar metal column and the Peltier module, and the high thermal conductivity of the titanium column as compared to a similar stainless steel printed column. The separation of peptides released from a digestion of E.coli was also achieved in less than 35 min with ca. 40 distinguishable peaks at 210 nm. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Pre-column dilution large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry for the analysis of multi-class pesticides in cabbages.

    Science.gov (United States)

    Zhong, Qisheng; Shen, Lingling; Liu, Jiaqi; Yu, Dianbao; Li, Siming; Yao, Jinting; Zhan, Song; Huang, Taohong; Hashi, Yuki; Kawano, Shin-ichi; Liu, Zhaofeng; Zhou, Ting

    2016-04-15

    Pre-column dilution large volume injection (PD-LVI), a novel sample injection technique for reverse phase ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), was developed in this study. The PD-LVI UHPLC-MS/MS system was designed by slightly modifying the commercial UHPLC-MS/MS equipment with a mixer chamber. During the procedure of PD-LVI, sample solution of 200μL was directly carried by the organic mobile phase to the mixer and diluted with the aqueous mobile phase. After the mixture was introduced to the UHPLC column in a mobile phase of acetonitrile-water (15/85, v/v), the target analytes were stacked on the head of the column until following separation. Using QuEChERS extraction, no additional steps such as solvent evaporation or residue redissolution were needed before injection. The features of PD-LVI UHPLC-MS/MS system were systematically investigated, including the injection volume, the mixer volume, the precondition time and the gradient elution. The efficiency of this approach was demonstrated by direct analysis of 24 pesticides in cabbages. Under the optimized conditions, low limits of detection (0.00074-0.8 ng/kg) were obtained. The recoveries were in the range of 63.3-109% with relative standard deviations less than 8.1%. Compared with common UHPLC-MS/MS technique, PD-LVI UHPLC-MS/MS showed significant advantages such as excellent sensitivity and reliability. The mechanism of PD-LVI was demonstrated to be based on the column-head stacking effect with pre-column dilution. Based on the results, PD-LVI as a simple and effective sample injection technique of reverse phase UHPLC-MS/MS for the analysis of trace analytes in complex samples showed a great promising prospect. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of semivolatile organic compounds in bottom sediment by solvent extraction, gel permeation chromatographic fractionation, and capillary-column gas chromatography/mass spectrometry

    Science.gov (United States)

    Furlong, E.T.; Vaught, D.G.; Merten, L.M.; Foreman, W.T.; Gates, Paul M.

    1996-01-01

    A method for the determination of 79 semivolatile organic compounds (SOCs) and 4 surrogate compounds in soils and bottom sediment is described. The SOCs are extracted from bottom sediment by solvent extraction, followed by partial isolation using high-performance gel permeation chromatography (GPC). The SOCs then are qualitatively identified and quantitative concentrations determined by capillary-column gas chromatography/mass spectrometry (GC/MS). This method also is designed for an optional simultaneous isolation of polychlorinated biphenyls (PCBs) and organochlorine (OC) insecticides, including toxaphene. When OCs and PCBs are determined, an additional alumina- over-silica column chromatography step follows GPC cleanup, and quantitation is by dual capillary- column gas chromatography with electron-capture detection (GC/ECD). Bottom-sediment samples are centrifuged to remove excess water and extracted overnight with dichloromethane. The extract is concentrated, centrifuged, and then filtered through a 0.2-micrometer polytetrafluoro-ethylene syringe filter. Two aliquots of the sample extract then are quantitatively injected onto two polystyrene- divinylbenzene GPC columns connected in series. The SOCs are eluted with dichloromethane, a fraction containing the SOCs is collected, and some coextracted interferences, including elemental sulfur, are separated and discarded. The SOC-containing GPC fraction then is analyzed by GC/MS. When desired, a second aliquot from GPC is further processed for OCs and PCBs by combined alumina-over-silica column chromatography. The two fractions produced in this cleanup then are analyzed by GC/ECD. This report fully describes and is limited to the determination of SOCs by GC/MS.

  10. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  11. Critical evaluation and comparison of fluid distribution systems for industrial scale expanded bed adsorption chromatography columns

    DEFF Research Database (Denmark)

    Arpanaei, Ayyoob; Heebøll-Nielsen, Anders; Hubbuch, Jürgen

    2008-01-01

    The hydrodynamic properties of an expanded bed contactor with 30 cm or 150 cm internal diameter, which employs a rotating or oscillating fluid distributor, were compared to prototype columns of 60 cm or 150 cm diameter employing local stirring (fixed wall nozzles plus central bottom mounted stirrer......) for fluid distribution. Fluid introduction through a rotating fluid distributor was found to give superior hydrodynamic characteristics in the 30 cm and 150 cm diameter column compared to using the local stirrer in both the 60 cm and 150 cm diameter columns. The shortcomings of the local stirring...... distributor at large scale were apparent: dead zones were present which could not be removed by increasing rotation rates or flow rates, and such changes led to a deterioration in hydrodynamic properties. In contrast, during fluid introduction through a rotating distributor no dead zones were observed...

  12. Semi-automated hydrophobic interaction chromatography column scouting used in the two-step purification of recombinant green fluorescent protein.

    Science.gov (United States)

    Stone, Orrin J; Biette, Kelly M; Murphy, Patrick J M

    2014-01-01

    Hydrophobic interaction chromatography (HIC) most commonly requires experimental determination (i.e., scouting) in order to select an optimal chromatographic medium for purifying a given target protein. Neither a two-step purification of untagged green fluorescent protein (GFP) from crude bacterial lysate using sequential HIC and size exclusion chromatography (SEC), nor HIC column scouting elution profiles of GFP, have been previously reported. Bacterial lysate expressing recombinant GFP was sequentially adsorbed to commercially available HIC columns containing butyl, octyl, and phenyl-based HIC ligands coupled to matrices of varying bead size. The lysate was fractionated using a linear ammonium phosphate salt gradient at constant pH. Collected HIC eluate fractions containing retained GFP were then pooled and further purified using high-resolution preparative SEC. Significant differences in presumptive GFP elution profiles were observed using in-line absorption spectrophotometry (A395) and post-run fluorimetry. SDS-PAGE and western blot demonstrated that fluorometric detection was the more accurate indicator of GFP elution in both HIC and SEC purification steps. Comparison of composite HIC column scouting data indicated that a phenyl ligand coupled to a 34 µm matrix produced the highest degree of target protein capture and separation. Conducting two-step protein purification using the preferred HIC medium followed by SEC resulted in a final, concentrated product with >98% protein purity. In-line absorbance spectrophotometry was not as precise of an indicator of GFP elution as post-run fluorimetry. These findings demonstrate the importance of utilizing a combination of detection methods when evaluating purification strategies. GFP is a well-characterized model protein, used heavily in educational settings and by researchers with limited protein purification experience, and the data and strategies presented here may aid in development other of HIC-compatible protein

  13. Semi-Automated Hydrophobic Interaction Chromatography Column Scouting Used in the Two-Step Purification of Recombinant Green Fluorescent Protein

    Science.gov (United States)

    Murphy, Patrick J. M.

    2014-01-01

    Background Hydrophobic interaction chromatography (HIC) most commonly requires experimental determination (i.e., scouting) in order to select an optimal chromatographic medium for purifying a given target protein. Neither a two-step purification of untagged green fluorescent protein (GFP) from crude bacterial lysate using sequential HIC and size exclusion chromatography (SEC), nor HIC column scouting elution profiles of GFP, have been previously reported. Methods and Results Bacterial lysate expressing recombinant GFP was sequentially adsorbed to commercially available HIC columns containing butyl, octyl, and phenyl-based HIC ligands coupled to matrices of varying bead size. The lysate was fractionated using a linear ammonium phosphate salt gradient at constant pH. Collected HIC eluate fractions containing retained GFP were then pooled and further purified using high-resolution preparative SEC. Significant differences in presumptive GFP elution profiles were observed using in-line absorption spectrophotometry (A395) and post-run fluorimetry. SDS-PAGE and western blot demonstrated that fluorometric detection was the more accurate indicator of GFP elution in both HIC and SEC purification steps. Comparison of composite HIC column scouting data indicated that a phenyl ligand coupled to a 34 µm matrix produced the highest degree of target protein capture and separation. Conclusions Conducting two-step protein purification using the preferred HIC medium followed by SEC resulted in a final, concentrated product with >98% protein purity. In-line absorbance spectrophotometry was not as precise of an indicator of GFP elution as post-run fluorimetry. These findings demonstrate the importance of utilizing a combination of detection methods when evaluating purification strategies. GFP is a well-characterized model protein, used heavily in educational settings and by researchers with limited protein purification experience, and the data and strategies presented here may aid in

  14. Supercritical Fluid Chromatography of Drugs: Parallel Factor Analysis for Column Testing in a Wide Range of Operational Conditions

    Directory of Open Access Journals (Sweden)

    Ramia Z. Al Bakain

    2017-01-01

    Full Text Available Retention mechanisms involved in supercritical fluid chromatography (SFC are influenced by interdependent parameters (temperature, pressure, chemistry of the mobile phase, and nature of the stationary phase, a complexity which makes the selection of a proper stationary phase for a given separation a challenging step. For the first time in SFC studies, Parallel Factor Analysis (PARAFAC was employed to evaluate the chromatographic behavior of eight different stationary phases in a wide range of chromatographic conditions (temperature, pressure, and gradient elution composition. Design of Experiment was used to optimize experiments involving 14 pharmaceutical compounds present in biological and/or environmental samples and with dissimilar physicochemical properties. The results showed the superiority of PARAFAC for the analysis of the three-way (column × drug × condition data array over unfolding the multiway array to matrices and performing several classical principal component analyses. Thanks to the PARAFAC components, similarity in columns’ function, chromatographic trend of drugs, and correlation between separation conditions could be simply depicted: columns were grouped according to their H-bonding forces, while gradient composition was dominating for condition classification. Also, the number of drugs could be efficiently reduced for columns classification as some of them exhibited a similar behavior, as shown by hierarchical clustering based on PARAFAC components.

  15. Separation of mercury(II), methylmercury and phenylmercury by micellar high-performance liquid chromatography on short columns

    International Nuclear Information System (INIS)

    Hutta, M.; Megova, S.; Halko, R.

    1998-01-01

    Three environmentally and agrochemically important mercury species: methylmercury, phenylmercury and mercury(II) are separated within 4 minutes as bromocomplexes by micellar liquid chromatography using very short reversed-phase (RP) C18 columns (up to 30 mm). The micellar mobile phase containing 0.05M cetyltrimethylammonium bromide (CTMA + Br - ), 1% (v/v) 2-propanol, 0.001M cyclohexylenediaminetetraacetic acid (DCTA) and sulfuric acid (pH 2) showed good selectivity in mixed reversed-phase and anion-exchange mode. The above mentioned separation order in which organomercurials are eluted far behind the void volume of the column, but before the mercury(II) peak is advantageous in all instances where mercury(II) is present in real samples in great excess. Environmental and agrochemical samples contain humic material which does not interfere in this particular system. The low cost photometric detection at 500 nm after post-column derivatization by CTMA + Br - micellized dithizone is almost free from interferences and enables detection limits at the 1-3 ng level (e.g., 0.1 ppm Hg) for 20 μl samples. (author)

  16. Application of a low impedance contactless conductometric detector for the determination of inorganic cations in capillary monolithic column chromatography.

    Science.gov (United States)

    Shen, Dazhong; Li, Dongdong; Yang, Xiuwen; Zhu, Yan; Dong, Jianfeng; Kang, Qi

    2011-03-15

    Poly(glycidyl methacrylate) cation exchange monolithic column was prepared in fused-silica capillaries of 320 μm i.d. by thermally initiated radical polymerization and utilized in capillary ion chromatography. With 15 mM methanesulfonic acid as the mobile phase, the separations of a mixture of inorganic cations (Li(+), Na(+), NH(4)(+), K(+)) was tested by using a capacitively coupled contactless conductivity detector (C(4)D) and a low impedance C(4)D (LIC(4)D). The LIC(4)D is the series combination of a C(4)D and a quartz crystal resonator. At the resonant frequency of the series combination, the capacitor impedance from capillary wall was offset by the inductance impedance from the quartz crystal resonator. A minimum impedance was obtained in the impedance-frequency curve of the combination. The responses of the C(4)D and LIC(4)D were analyzed based on an equivalent circuit model. It was shown that the sensitivity of the C(4)D to the change in analyte concentration is rather poor due to the high ratio of the impedance from the capillary wall capacitor to the solution impedance. The LIC(4)D has the similar sensitivity as a contact conductivity detector but a much smaller cell volume. The on-column detection model was realized by LiC(4)D without preparation of optical detection window in monolithic column. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Zwitterionic silica-based monolithic capillary columns for isocratic and gradient hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Moravcová, Dana; Planeta, Josef; Kahle, Vladislav; Roth, Michal

    2012-12-28

    This study introduces zwitterionic monolithic capillary columns intended for isocratic and gradient HILIC separations. Silica-based monolithic capillary columns (100 μm × 150 mm) prepared by acidic hydrolysis of tetramethoxysilane in the presence of polyethylene glycol and urea were modified by a sulfoalkylbetaine zwitterion ([2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl)-ammonium hydroxide) to HILIC stationary phase. The prepared columns were evaluated under the isocratic and gradient separation conditions using a standard mixture containing nucleic acid bases, nucleosides, and 2-deoxynucleosides. Mobile phases contained high concentration of acetonitrile (95-85%, v/v) and 5-50mM ammonium acetate or ammonium formate in the pH range of 3-6. The synthesized columns showed a long-term stability under the separation conditions while the high permeability and efficiency originating from dual structure of the silica monolith were preserved. The relative standard deviations (RSDs) for the retention times of tested solutes were lower than 2% under the isocratic conditions and lower than 3.5% under the gradient conditions. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Preparation of a monolitich capillary column with immobilized a-mannose for affinity chromatography of lectins

    NARCIS (Netherlands)

    Tetala, K.K.R.; Chen, B.; Visser, G.M.; Maruska, A.; Kornysova, O.; Beek, van T.A.; Sudhölter, E.J.R.

    2007-01-01

    A simple method for the preparation of an affinity monolithic (also called continuous bed) capillary column for ¿-mannose-specific lectins is described. 2-Hydroxyethyl methacrylate in combination with (+)-N,N´-diallyltartardiamide (DATD) and piperazine diacrylamide (PDA, 1,4-bisacryloyl-piperazine)

  19. Monolithic columns with immobilized monomeric avidin: preparation and application for affinity chromatography.

    Science.gov (United States)

    Spross, Jens; Sinz, Andrea

    2012-03-01

    A poly(glycidyl methacrylate-co-acrylamide-co-ethylene dimethacrylate) monolith and a poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith were prepared in fused silica capillaries (100 μm ID) and modified with monomeric avidin using the glutaraldehyde technique. The biotin binding capacity of monolithic affinity columns with immobilized monomeric avidin (MACMAs) was determined by fluorescence spectroscopy using biotin (5-fluorescein) conjugate, as well as biotin- and fluorescein-labeled bovine serum albumin (BSA). The affinity columns were able to bind 16.4 and 3.7 μmol biotin/mL, respectively. Columns prepared using the poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith retained 7.1 mg BSA/mL, almost six times more than commercially available monomeric avidin beads. Protocols based on MALDI-TOF mass spectrometry monitoring were optimized for the enrichment of biotinylated proteins and peptides. A comparison of enrichment efficiencies between MACMAs and commercially available monomeric avidin beads yielded superior results for our novel monolithic affinity columns. However, the affinity medium presented in this work suffers from a significant degree of nonspecific binding, which might hamper the analysis of more complex mixtures. Further modifications of the monolith's surface are envisaged for the future development of monoliths with improved enrichment characteristics.

  20. Capillary liquid chromatography separations using non-porous pillar array columns

    NARCIS (Netherlands)

    de Malsche, Wim; de Bruyne, S.; op de Beek, J.; Sandra, P.; Gardeniers, Johannes G.E.; Desmet, G.; Lynen, F.

    2012-01-01

    We report on a series of explorative experiments wherein a non-porous pillar array column (NP-PAC) is coupled to a commercial capillary LC instrument. The performance of the system was evaluated by both non-retained and retained experiments using several types of samples. In order to minimize

  1. Three column intermittent simulated moving bed chromatography: 1. Process description and comparative assessment.

    Science.gov (United States)

    Jermann, Simon; Mazzotti, Marco

    2014-09-26

    The three column intermittent simulated moving bed (3C-ISMB) process is a new type of multi-column chromatographic process for binary separations and can be regarded as a modification of the I-SMB process commercialized by Nippon Rensui Corporation. In contrast to conventional I-SMB, this enables the use of only three instead of four columns without compromising product purity and throughput. The novel mode of operation is characterized by intermittent feeding and product withdrawal as well as by partial recycling of the weakly retained component from section III to section I. Due to the smaller number of columns with respect to conventional I-SMB, higher internal flow rates can be applied without violating pressure drop constraints. Therefore, the application of 3C-ISMB allows for a higher throughput whilst using a smaller number of columns. As a result, we expect that the productivity given in terms of throughput per unit time and unit volume of stationary phase can be significantly increased. In this contribution, we describe the new process concept in detail and analyze its cyclic steady state behavior through an extensive simulation study. The latter shows that 3C-ISMB can be easily designed by Triangle Theory even under highly non-linear conditions. The simple process design is an important advantage to other advanced SMB-like processes. Moreover, the simulation study demonstrates the superior performance of 3C-ISMB, namely productivity increases by roughly 60% with respect to conventional I-SMB without significantly sacrificing solvent consumption. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Preparation of organic monolithic columns in polytetrafluoroethylene tubes for reversed-phase liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Catalá-Icardo, M., E-mail: mocaic@qim.upv.es [Research Institute for Integrated Management of Coastal Areas, Universitat Politècnica de València, Paranimf 1, 46730, Grao de Gandía, Valencia (Spain); Torres-Cartas, S.; Meseguer-Lloret, S.; Gómez-Benito, C. [Research Institute for Integrated Management of Coastal Areas, Universitat Politècnica de València, Paranimf 1, 46730, Grao de Gandía, Valencia (Spain); Carrasco-Correa, E.; Simó-Alfonso, E.F.; Ramis-Ramos, G. [Department of Analytical Chemistry, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia (Spain); Herrero-Martínez, J.M., E-mail: jmherrer@uv.es [Department of Analytical Chemistry, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia (Spain)

    2017-04-01

    In this work, a method for the preparation and anchoring of polymeric monoliths in a polytetrafluoroethylene (PTFE) tubing as a column housing for microbore HPLC is described. In order to assure a covalent attachment of the monolith to the inner wall of the PTFE tube, a two-step procedure was developed. Two surface etching reagents, a commercial sodium naphthalene solution (Fluoroetch{sup ®}), or mixtures of H{sub 2}O{sub 2} and H{sub 2}SO{sub 4}, were tried and compared. Then, the obtained hydroxyl groups on the PTFE surface were modified by methacryloylation. Attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification of the tubing wall and the stable anchorage of monolith to the wall, respectively. Special emphasis was also put on the reduction of the unwanted effects of shrinking of monolith during polymerization, by using an external proper mold and by selecting the adequate monomers in order to increase the flexibility of the polymer. Poly(glycidyl methacrylate-co-divinylbenzene) monoliths were in situ synthesized by thermal polymerization within the confines of surface-vinylized PTFE tubes. The modified PTFE tubing tightly held the monolith, and the monolithic column exhibited good pressure resistance up to 20 MPa. The column performance was also evaluated via the isocratic separation of a series of alkylbenzenes in the reversed-phase mode. The optimized monolithic columns gave plate heights ranged between 70 and 80 μm. The resulting monoliths were also satisfactorily applied to the separation of proteins. - Highlights: • Successful surface etching of PTFE inner wall tubing was done. • The modified PTFE support was next methacryloylated with GMA. • Organic polymeric monolith was in situ prepared in the functionalized PTFE tube. • The monolithic columns gave suitable pressure resistance and separation of proteins.

  3. Comprehensive and Reproducible Phosphopeptide Enrichment Using Iron Immobilized Metal Ion Affinity Chromatography (Fe-IMAC) Columns

    NARCIS (Netherlands)

    Ruprecht, Benjamin; Koch, Heiner; Medard, Guillaume; Mundt, Max; Kuster, Bernhard; Lemeer, Simone

    Advances in phosphopeptide enrichment methods enable the identification of thousands of phosphopeptides from complex samples. Current offline enrichment approaches using TiO2, Ti, and Fe immobilized metal ion affinity chromatography (IMAC) material in batch or microtip format are widely used, but

  4. Column liquid chromatography- mass spectrometry: selected techniques in environmental applications for polar pesticides and related compounds.

    NARCIS (Netherlands)

    Slobodnik, J.; van Baar, B.L.M.; Brinkman, U.A.T.

    1995-01-01

    A review covering the field of environmental applications of liquid chromatography-mass spectrometry (LC-MS) is presented. Recent developments and advances are discussed with emphasis on the presently popular thermospray, particle beam and atmospheric pressure ionisation interfaces. Each interface

  5. Extending the upper temperature range of gas chromatography with all-silicon microchip columns using a heater/clamp assembly.

    Science.gov (United States)

    Ghosh, Abhijit; Johnson, Jacob E; Nuss, Johnathan G; Stark, Brittany A; Hawkins, Aaron R; Tolley, Luke T; Iverson, Brian D; Tolley, H Dennis; Lee, Milton L

    2017-09-29

    Miniaturization of gas chromatography (GC) instrumentation is of interest because it addresses current and future issues relating to compactness, portability and field application. While incremental advancements continue to be reported in GC with columns fabricated in microchips (referred to in this paper as "microchip columns"), the current performance is far from acceptable. This lower performance compared to conventional GC is due to factors such as pooling of the stationary phase in corners of non-cylindrical channels, adsorption of sensitive compounds on incompletely deactivated surfaces, shorter column lengths and less than optimum interfacing to injector and detector. In this work, a GC system utilizing microchip columns was developed that solves the latter challenge, i.e., microchip interfacing to injector and detector. A microchip compression clamp was constructed to heat the microchip (i.e., primary heater), and seal the injector and detector fused silica interface tubing to the inlet and outlet ports of the microchip channels with minimum extra-column dead volume. This clamp allowed occasional operation up to 375°C and routine operation up to 300°C. The compression clamp was constructed of a low expansion alloy, Kovar™, to minimize leaking due to thermal expansion mismatch at the interface during repeated thermal cycling, and it was tested over several months for more than one hundred injections without forming leaks. A 5.9m long microcolumn with rectangular cross section of 158μm×80μm, which approximately matches a 100μm i.d. cylindrical fused silica column, was fabricated in a silicon wafer using deep reactive ion etching (DRIE) and high temperature fusion bonding; finally, the channel was coated statically with a 1% vinyl, 5% phenyl, 94% methylpolysiloxane stationary phase. High temperature separations of C10-C40 n-alkanes and a commercial diesel sample were demonstrated using the system under both temperature programmed GC (TPGC) and thermal

  6. Zwitterionic silica-based monolithic capillary columns for isocratic and gradient hydrophilic interaction liquid chromatography

    Czech Academy of Sciences Publication Activity Database

    Moravcová, Dana; Planeta, Josef; Kahle, Vladislav; Roth, Michal

    2012-01-01

    Roč. 1270, DEC 28 (2012), s. 178-185 ISSN 0021-9673 R&D Projects: GA MV VG20112015021; GA ČR(CZ) GAP206/11/0138; GA ČR(CZ) GAP106/12/0522 Institutional support: RVO:68081715 Keywords : HILIC * Monolithic silica column * Nucleoside separation * Nucleic acid base Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.612, year: 2012

  7. Bridged polysilsesquioxane-based wide-bore monolithic capillary columns for hydrophilic interaction chromatography

    Czech Academy of Sciences Publication Activity Database

    Šesták, Jozef; Moravcová, Dana; Křenková, Jana; Planeta, Josef; Roth, Michal; Foret, František

    2017-01-01

    Roč. 1479, JAN (2017), s. 204-209 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GA14-06319S; GA ČR(CZ) GA16-03749S Institutional support: RVO:68081715 Keywords : silica monolithic column * HILIC * oligosaccharides * nucleosides Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 3.981, year: 2016

  8. Behavior of short silica monolithic columns in high pressure gas chromatography.

    Science.gov (United States)

    Maniquet, Adrien; Bruyer, Nicolas; Raffin, Guy; Baco-Antoniali, Franck; Demesmay, Claire; Dugas, Vincent; Randon, Jérôme

    2016-08-19

    In order to analyze light hydrocarbons mixtures with silica monolithic columns, a conventional gas chromatograph was modified to work with carrier gas pressure as high as 60bar. To understand hydrodynamic flow and retention with short columns (less than 30cm), special attention was required due to the temperature difference between the oven area and the FID detector which contain a significant length of the column. Efficiency and selectivity using various carrier gases (helium, nitrogen and carbon dioxide) at different inlet pressure for different oven temperature were studied. Carrier gas nature was a very significant parameter: on one side, linked to adsorption mechanism for gases like nitrogen and carbon dioxide onto the stationary phase modifying retention and selectivity, on the other side in relation to the minimum theoretical plate height which was as low as 15μm (66 000 platem(-1)) using carbon dioxide as carrier gas. The chromatographic system was then used to separate methane, ethane, ethylene, acetylene, propane, cyclopropane, and butane in less than 30s. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. A Continuous Procedure Based on Column Chromatography to Purify Anthocyanins from Schisandra chinensis by a Macroporous Resin plus Gel Filtration Chromatography

    Directory of Open Access Journals (Sweden)

    Daran Yue

    2016-02-01

    Full Text Available In our previous study, as natural food colorants and antioxidants, the color and content stabilities of Schisandra chinensis (S. chinensis anthocyanins were investigated. In this work, the purification process parameters of S. chinensis anthocyanins using a macroporous resin and gel filtration chromatography were evaluated. The optimized parameters of static adsorption and desorption were as follows. The selected resin is HPD-300 (nonpolar copolymer styrene type resin, and the anthocyanins adsorption saturation capacity of HPD-300 resin was 0.475 mg/g dry resin. Adsorption time was 4 h, and 0.517 mg/mL of S. chinensis anthocyanins was adsorbed on the resin column with a flow rate of 39 mL/h (3 BV/h. After adsorption, the anthocyanins were completely desorpted with 2.5 BV of 90% (v/v ethanol solution, and the desorption flow rate was 13 mL/h (1 BV/h. After purification by dynamic adsorption and desorption, the anthocyanins content in the effluent increased from 47.6 mg/g to 128.4 mg/g, the purity of anthocyanins increased six-fold from 5.08% to 30.43%, and the anthocyanins recovery was 96.5%. The major constituent of S. chinensis anthocyanins was isolated with Bio-Gel P2 gel filtration chromatography, and it was detected by liquid chromatography electrospray ionisation tandem mass spectrometry (LC-ESI-MS as cyanidin-3-O-xylosylrutinoside. Moreover, the antioxidant activities of S. chinensis anthocyanins were investigated. After purification using the HPD-300 resin, the antioxidant activities of anthocyanins were increased 1.2-fold (FRAP and 1.7-fold (ABTS.

  10. Combining prior knowledge with data-driven modeling of a batch distillation column including start-up

    NARCIS (Netherlands)

    van Lith, P.F.; van Lith, Pascal F.; Betlem, Bernardus H.L.; Roffel, B.

    2003-01-01

    This paper presents the development of a simple model which describes the product quality and production over time of an experimental batch distillation column, including start-up. The model structure is based on a simple physical framework, which is augmented with fuzzy logic. This provides a way

  11. Separation of PCBs by liquid chromatography on reversed phase sub-2-micron particle columns

    Czech Academy of Sciences Publication Activity Database

    Olšovská, Jana; Křesinová, Zdena; Flieger, Miroslav; Cajthaml, Tomáš

    2010-01-01

    Roč. 80, č. 5 (2010), s. 1849-1855 ISSN 0039-9140 R&D Projects: GA MŠk 2B06156; GA ČR GA525/09/1058 Institutional research plan: CEZ:AV0Z50200510 Keywords : Ultra high-performance liquid chromatography * PCB * Congener analysis Subject RIV: EE - Microbiology, Virology Impact factor: 3.722, year: 2010

  12. Automatic collection of the rare-earths with post chromatography column detection

    International Nuclear Information System (INIS)

    David, P.; Metzger, G.; Repellin, M.

    1987-01-01

    The complete separation of rare-earths (in the aim of radio-isotopes measurement) requires High Performance Liquid Chromatography with ternary elution gradient. To automatize their collection with satisfying conditions, we have realized a non polluting, reliable and easy to operate detection method. This one is based on a derivation colorimetric system with arsenazo I (3 -(2 arsophenylazo 4.5) - dihydroxy - 2.7 naphtalene disulfonic acid)

  13. Microfluidic Columns with Nanotechnology-Enabled Stationary Phases for Gas Chromatography

    OpenAIRE

    Shakeel, Hamza

    2015-01-01

    Advances in micro-electro-mechanical-systems (MEMS) along with nanotechnology based methods have enabled the miniaturization of analytical chemistry instrumentation. The broader aim is to provide a portable, low-cost, and low-power platform for the real-time detection and identification of organic compounds in a wide variety of applications. A benchtop gas chromatography (GC) system is considered a gold standard for chemical analysis by analytical chemists. Similarly, miniaturization of key G...

  14. A two-column flash chromatography approach to pyoverdin production from Pseudomonas putida GB1.

    Science.gov (United States)

    Duckworth, Owen W; Markarian, Dawn S; Parker, Dorothy L; Harrington, James M

    2017-04-01

    Our knowledge of the biological and environmental reactivity of siderophores is limited by the difficulty and cost of obtaining reasonable quantities by purification or synthesis. In this note, we describe a modified procedure for the low-cost, mg-scale purification of pyoverdin-type siderophores using a dual-flash chromatography (reverse-phase absorption and size exclusion) approach. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Preparation of quaternary amine monolithic column for strong anion-exchange chromatography and its application to the separation of Enterovirus 71.

    Science.gov (United States)

    Gu, Huimin; Yin, Dezhong; Ren, Jie; Zhang, Baoliang; Zhang, Qiuyu

    2016-10-15

    Large size virion is unable to diffuse into pores of conventional porous chromatography particles. Therefore, separation of virion by conventional column-packing materials is not quite efficient. To solve this problem, a monolithic column with large convective pores and quaternary amine groups was prepared and was applied to separate Enterovirus 71 (EV71, ≈5700-6000kDa). Cross-section, pore structure, hydrodynamic performance, adsorption property and dynamic binding capacity of prepared monolithic column were determined. Double-pore structures, macropore at 2472nm and mesopore at 5-60nm, were formed. The porosity was up to 63.3%, which enable higher permeability and lower back pressure of the monolithic column than commercial UNO™ Q1 column. Based on the breakthrough curves, the loading capacity of bovine serum albumin was calculated to be 42.0mg per column. In addition, prepared quaternary amine monolithic column was proved to be suitable for the separation of protein mixture by strong anion-exchange chromatography. As a practical application, prepared monolith column presents excellent performance to the separation of EV71 from virus-proteins mixture. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Acylhydrazone bond dynamic covalent polymer gel monolithic column online coupling to high-performance liquid chromatography for analysis of sulfonamides and fluorescent whitening agents in food.

    Science.gov (United States)

    Zhang, Chengjiang; Luo, Xialin; Wei, Tianfu; Hu, Yufei; Li, Gongke; Zhang, Zhuomin

    2017-10-13

    A new dynamic covalent polymer (DCP) gel was well designed and constructed based on imine chemistry. Polycondensation of 4,4'-biphenyldicarboxaldehyde and 1,3,5-benzenetricarbohydrazide via Schiff-base reaction resulted in an acylhydrazone bond gel (AB-gel) DCP. AB-gel DCP had three-dimensional network of interconnected nanoparticles with hierarchically porous structure. AB-gel DCP was successfully fabricated as a monolithic column by an in-situ chemical bonding method for online enrichment and separation purpose with excellent permeability. AB-gel DCP based monolithic column showed remarkable adsorption affinity towards target analytes including sulfonamides (SAs) and fluorescent whitening agents (FWAs) due to its strong π-π affinity, hydrophobic effect and hydrogen bonding interaction. Then, AB-gel DCP based monolithic column was applied for online separation and analysis of trace SAs and FWAs in food samples coupled with high-performance liquid chromatography (HPLC). Sulfathiazole (ST) and sulfadimidine (SM2) in one positive weever sample were actually found and determined with concentrations of 273.8 and 286.3μg/kg, respectively. 2,5-Bis(5-tert-butyl-2-benzoxazolyl) thiophene (FWA184) was actually quantified in one tea infusion sample with the concentration of 268.5ng/L. The spiked experiments suggested the good recoveries in range of 74.5-110% for SAs in weever and shrimp samples with relative standard deviations (RSDs) less than 9.7% and in range of 74.0-113% for FWAs in milk and tea infusion samples with RSDs less than 9.0%. AB-gel DCP monolithic column was proved to be a promising sample preparation medium for online separation and analysis of trace analytes in food samples with complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Online hyphenation of extraction, Sephadex LH-20 column chromatography, and high-speed countercurrent chromatography: A highly efficient strategy for the preparative separation of andrographolide from Andrographis paniculata in a single step.

    Science.gov (United States)

    Zhang, Ying-Qi; Wang, Shan-Shan; Han, Chao; Xu, Jin-Fang; Luo, Jian-Guang; Kong, Ling-Yi

    2017-12-01

    A novel isolation strategy, online hyphenation of ultrasonic extraction, Sephadex LH-20 column chromatography combined with high-speed countercurrent chromatography, was developed for pure compounds extraction and purification. Andrographolide from Andrographis paniculata was achieved only in a single step purification protocol via the present strategy. The crude powder was ultrasonic extracted and extraction was pumped into Sephadex LH-20 column directly to cut the nontarget fractions followed by the second-dimensional high-speed countercurrent chromatography, hyphenated by a six-port valve equipped at the post-end of Sephadex LH-20 column, for the final purification. The results yielded andrographolide with the amount of 1.02 mg and a purity of 98.5% in a single step, indicating that the present method is effective to harvest target compound from medicinal plant. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Study of the enantiomeric separation of oxfendazole and cetirizine using subcritical fluid chromatography on an amylose-based column.

    Science.gov (United States)

    Toribio, L; del Nozal, M J; Bernal, J L; Cristofol, C; Alonso, C

    2006-07-21

    The enantiomeric separation of cetirizine and oxfendazole on a Chiralpak AD column using subcritical fluid chromatography has been studied in this work. The enantioseparation of cetirizine was only possible when 2-propanol was used as a modifier, obtaining better results in presence of the additives triethylamine (TEA) and trifluoroacetic acid (TFAA). On the contrary, 2-propanol provided the lowest enantioresolutions for oxfendazole, in this case the best results in terms of high resolution and short analysis time were obtained with ethanol. The study of the temperature effect revealed that in the case of cetirizine using 2-propanol, and oxfendazole using methanol, the separation was enthalpy-driven and the isoelution temperature was above the working range. Using ethanol or 2-propanol, the results showed that the oxfendazole enantioseparation was entropically driven and the isoelution temperatures were below the range studied.

  19. Simultaneous determination of metoprolol and metabolites in urine by capillary column gas chromatography as oxazolidineone and trimethylsilyl derivatives.

    Science.gov (United States)

    Gyllenhaal, O; Hoffmann, K J

    1984-08-10

    A method for the determination of metoprolol and its main metabolites in urine is presented. The method comprises derivatization of the aminopropanol side-chain with phosgene at alkaline pH and isolation in an organic phase at acidic pH. After trimethylsilylation, separation and quantification are performed by capillary column gas chromatography with flame ionization detection. The reaction is performed at pH 12 with 60 microliters of 2 M phosgene in toluene added in three portions. Diethyl ether--dichloromethane is used as extraction medium and bis(trimethylsilyl) acetamide as silylating agent. With spiked samples linear standard curves were obtained for metoprolol and three of its main metabolites with a detection limit varying between 4 and 20 mumol/l of urine. The method was applied to urine samples from a normal individual who had taken 292 mumol of metoprolol as tartrate.

  20. Speciation of mercury by ion chromatography with post-column derivatization

    International Nuclear Information System (INIS)

    Foltin, M.; Megova, S.; Prochakova, T.; Steklac, M.

    1996-01-01

    The chromatographic behaviour of Hg(II), methylmercury, phenylmercury and Cu(II) on three different sorbents, strong acidic sulfobutyl cation-exchanger, weak basic aminopropyl anion-exchanger and silicagel has been studied. A dithizone solution in cetyltrimethylammonium hydrogensulfate water micellar medium was found as a useful post-column derivatization reagent for UV-VIS detection. The detection limits 1.1 ng, 2.2 ng, 6.2 ng and 1.6 ng were found in silicagel chromatographic system and dithizone detection system for Hg(II), methylmercury, phenylmercury and respectively for Cu(II). (author). 18 refs., 4 figs., 3 tabs

  1. Immunoaffinity column clean-up and thin layer chromatography for determination of ochratoxin A in green coffee.

    Science.gov (United States)

    Santos, E A; Vargas, E A

    2002-05-01

    An immunoaffinity clean-up-based method for determining ochratoxin A (OTA) in green coffee aiming at one-dimensional thin layer chromatography (TLC) analysis was established. OTA was extracted with a mixture of methanol and aqueous sodium hydrogen carbonate solution, purified through an immunoaffinity column, separated on normal or reversed-phase (RP) TLC plates and detected and quantified by visual and densitometric analysis. The linear equation of the standard calibration curve by densitometric analysis gave R(2) > 0.999 (0.04-84 ng). The mean recovery (R) of OTA from spiked samples (1.8-109 microg kg(-1)) by densitometric and visual analyses were 98.4 and 103.8%, respectively. The relative standard deviations (RSD) for densitometric and visual analysis varied from 1.1 to 24.9% and from 0.0 to 18.8%, respectively. The RSD for naturally contaminated samples by densitometry (three levels of contamination, n = 3) varied from 11.1 to 18.1%. The correlation (R(2)) between high-performance liquid chromatography (HPLC) and densitometry, and between visual and densitometric analysis for spiked samples were > 0.99. The limit of detection (LOD) of the method was 0.5 microg kg(-1) for normal TLC. Toluene-ethyl acetate-88% formic acid (6:3:1 v/v/v) and acetonitrile-methanol-water-glacial acetic acid (35:35:29:10 v/v/v/v) were regarded as the suitable TLC solvents for eluting both standards and samples on normal and RP TLC plates, respectively. Toluene-acetic acid (99:1 v/v) was chosen as the spotting solvent among several others for giving the best sensitivity and resolution of OTA on TLC plates as well as the best recovery of OTA from standard and sample extract residues. Preliminary studies were carried out to investigate the reuse of the immunoaffinity column and the interference of caffeine in the OTA recovery.

  2. Quantitative analysis of three chiral pesticide enantiomers by high-performance column liquid chromatography.

    Science.gov (United States)

    Wang, Peng; Liu, Donghui; Gu, Xu; Jiang, Shuren; Zhou, Zhiqiang

    2008-01-01

    Methods for the enantiomeric quantitative determination of 3 chiral pesticides, paclobutrazol, myclobutanil, and uniconazole, and their residues in soil and water are reported. An effective chiral high-performance liquid chromatographic (HPLC)-UV method using an amylose-tris(3,5-dimethylphenylcarbamate; AD) column was developed for resolving the enantiomers and quantitative determination. The enantiomers were identified by a circular dichroism detector. Validation involved complete resolution of each of the 2 enantiomers, plus determination of linearity, precision, and limit of detection (LOD). The pesticide enantiomers were isolated by solvent extraction from soil and C18 solid-phase extraction from water. The 2 enantiomers of the 3 pesticides could be completely separated on the AD column using n-hexane isopropanol mobile phase. The linearity and precision results indicated that the method was reliable for the quantitative analysis of the enantiomers. LODs were 0.025, 0.05, and 0.05 mg/kg for each enantiomer of paclobutrazol, myclobutanil, and uniconazole, respectively. Recovery and precision data showed that the pretreatment procedures were satisfactory for enantiomer extraction and cleanup. This method can be used for optical purity determination of technical material and analysis of environmental residues.

  3. Aflatoxin evaluation in ready-to-eat brazil nuts using reversed-phase liquid chromatography and post-column derivatisation.

    Science.gov (United States)

    Iamanaka, Beatriz Thie; Nakano, Felipe; Lemes, Daniel Ponciano; Ferranti, Larissa Souza; Taniwaki, Marta Hiromi

    2014-01-01

    A high-performance liquid chromatography-fluorescence (HPLC-FD) method for aflatoxin quantification in brazil nuts was developed. Samples of brazil nuts collected in Brazilian markets were extracted with methanol:water and cleaned using an immunoaffinity column. Aflatoxins were eluted with methanol and a post-column derivatisation was performed with bromine, using a Kobra Cell system. The optimised method for total aflatoxins was sensitive, with detection and quantification limits of 0.05 and 0.25 µg kg⁻¹, respectively. The method was accurate, with recovery values of 87.6%; 85.3% and 85.0% for 0.5, 5.0 and 14.6 µg kg⁻¹ spiked levels, respectively. It was shown that the method was applicable to brazil nuts. From a total of 95 brazil nut samples analysed from 21 São Paulo supermarket samples and 51 Manaus and 23 Belém street markets samples, 37.9% showed detectable levels of aflatoxins and three exceeded the recommended Codex Alimentarius limit of 10 µg kg⁻¹ for ready-to-eat brazil nuts.

  4. Columns and optimum gradient conditions for fast second-dimension separations in comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Hájek, Tomáš; Jandera, Pavel

    2012-07-01

    Gradient elution provides significantly higher peak capacity in comparison to the isocratic elution mode, hence it is very useful in online comprehensive two-dimensional liquid chromatography (LC). We compared suitability of five commercial core-shell columns and one monolithic column for fast gradients in the second LC dimension, where the time of separation is strictly limited by the fraction cycle time. In two-dimensional reversed-phase systems with partially correlated retention, the resolution, the peak capacity, and the regularity of coverage of the second-dimension retention space can be improved by appropriate adjusting the gradient time and the gradient range to suit the sample properties. We developed a new strategy for adjusting the gradient mobile phase composition range in the second-dimension, employing the retention data of representative sample standards characterizing the sample properties, which can be calibrated using the reference alkylbenzene series. Optimized second-dimension gradients with single-step or segmented profiles covering two or more fraction ranges, employed for the separation of subsequent fractions from the first-dimension, improve significantly the resolution, the separation time, and the regularity of coverage of the two-dimensional retention plane. The approach was applied to the two-dimensional comprehensive separation of phenolic acids and flavonoid compounds occurring as natural antioxidants. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Modeling retention and selectivity as a function of pH and column temperature in liquid chromatography.

    Science.gov (United States)

    Gagliardi, Leonardo G; Castells, Cecilia B; Ràfols, Clara; Rosés, Martí; Bosch, Elisabeth

    2006-08-15

    In reversed-phase liquid chromatography (RPLC), the retention of weak acids and bases is a sigmoidal function of the mobile-phase pH. Therefore, pH is a key chromatographic variable to optimize retention and selectivity. Furthermore, at an eluent pH close to the pKa of the solute, the dependence of ionization of the buffer and solute on temperature can be used to improve chromatographic separations involving ionizable solutes by an adequate handling of column temperature. In this paper, we derive a general equation for the prediction of the retentive behavior of ionizable compounds upon simultaneous changes in mobile-phase pH and column temperature. Four experiments, two limiting pH values and two temperatures, provide the input data that allow predictions in the whole range of these two variables, based on the thermodynamic fundamentals of the involved equilibria. Also, the study demonstrates the significant role that the choice of the buffer compound would have on selectivity factors in RPLC at temperatures higher than 25 degrees C.

  6. Analysis of trace inorganic anions in weak acid salts by single pump cycling-column-switching ion chromatography.

    Science.gov (United States)

    Huang, Zhongping; Ni, Chengzhu; Zhu, Zhuyi; Pan, Zaifa; Wang, Lili; Zhu, Yan

    2015-05-01

    The application of ion chromatography with the single pump cycling-column-switching technique was described for the analysis of trace inorganic anions in weak acid salts within a single run. Due to the hydrogen ions provided by an anion suppressor electrolyzing water, weak acid anions could be transformed into weak acids, existing as molecules, after passing through the suppressor. Therefore, an anion suppressor and ion-exclusion column were adopted to achieve on-line matrix elimination of weak acid anions with high concentration for the analysis of trace inorganic anions in weak acid salts. A series of standard solutions consisting of target anions of various concentrations from 0.005 to 10 mg/L were analyzed, with correlation coefficients r ≥ 0.9990. The limits of detection were in the range of 0.67 to 1.51 μg/L, based on the signal-to-noise ratio of 3 and a 25 μL injection volume. Relative standard deviations for retention time, peak area, and peak height were all less than 2.01%. A spiking study was performed with satisfactory recoveries between 90.3 and 104.4% for all anions. The chromatographic system was successfully applied to the analysis of trace inorganic anions in five weak acid salts. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Residual on column host cell protein analysis during lifetime studies of protein A chromatography.

    Science.gov (United States)

    Lintern, Katherine; Pathak, Mili; Smales, C Mark; Howland, Kevin; Rathore, Anurag; Bracewell, Daniel G

    2016-08-26

    Capacity reduction in protein A affinity chromatography with extended cycling during therapeutic antibody manufacture is well documented. Identification of which residual proteins remain from previous cycles during the lifetime of these adsorbent materials is required to understand their role in this ageing process, but represents a significant metrological challenge. Scanning electron microscopy (SEM) and liquid chromatography mass spectrometry (LC-MS/MS) are combined to detect and map this phenomenon of protein carry-over. We show that there is a morphological change at the surface of the agarose resin, revealing deposits on the polymer fibres increasing with cycle number. The amount of residual host cell proteins (HCPs) by LC-MS/MS present on the resin is shown to increase 10-fold between 50 and 100 cycles. During this same period the functional class of the predominant HCPs associated with the resin increased in diversity, with number of proteins identified increasing 5-fold. This ageing is observed in the context of the product quality of the eluate HCP and protein A leachate concentration remaining constant with cycle number. Copyright © 2016 The Author(s). Published by Elsevier B.V. All rights reserved.

  8. pH transients in hydroxyapatite chromatography columns-Effects of operating conditions and media properties.

    Science.gov (United States)

    Dattolo, Laura; Keller, Emily L; Carta, Giorgio

    2010-11-26

    pH transitions occur in hydroxyapatite (HAP) columns that are subject to step changes in salt concentration, which have been shown to be controlled by proton exchange on the HAP surface. The pH temporarily decreases before gradually returning to the feed value when the salt concentration increases, potentially compromising the stability of the HAP when either the magnitude or duration of the pH drop is excessive. The opposite happens when the salt concentration decreases. In this work we address the effects of several key variables: the flow rate, the particle size, the use of salt gradients instead of steps, the use of different co-buffers, the surface area of the HAP, and the use of a slightly alkaline wash prior to increasing the salt concentration. Flow rate and particle size were found to have virtually no effect, demonstrating that the pH transitions are equilibrium rather than kinetically driven. Salt gradients resulted in smaller pH drops compared to steps since the exchanged protons are diluted over the gradient volume. MES and histidine used as co-buffers were effective at reducing the duration of the pH transitions but did not affect their magnitude. The same result was found when comparing HAP samples with different surface areas, with the lower surface area HAP yielding much shorter duration but similar pH drops and rises. Finally, washing the HAP column with a pH 7.5 buffer prior to the salt step was found to dramatically reduce the subsequent pH drop. In general, there was good agreement between these results and predictions based on our previously developed model. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Separation techniques: Chromatography

    Science.gov (United States)

    Coskun, Ozlem

    2016-01-01

    Chromatography is an important biophysical technique that enables the separation, identification, and purification of the components of a mixture for qualitative and quantitative analysis. Proteins can be purified based on characteristics such as size and shape, total charge, hydrophobic groups present on the surface, and binding capacity with the stationary phase. Four separation techniques based on molecular characteristics and interaction type use mechanisms of ion exchange, surface adsorption, partition, and size exclusion. Other chromatography techniques are based on the stationary bed, including column, thin layer, and paper chromatography. Column chromatography is one of the most common methods of protein purification. PMID:28058406

  10. A column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry method to determine anandamide and 2-arachidonoylglycerol in plasma samples.

    Science.gov (United States)

    Marchioni, Camila; de Souza, Israel Donizeti; Grecco, Caroline Fernandes; Crippa, José Alexandre; Tumas, Vitor; Queiroz, Maria Eugênia Costa

    2017-05-01

    This study reports a fast, sensitive, and selective column switching ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine the endocannabinoids (eCBs), anandamide (AEA), and 2-arachidonoylglycerol (2-AG) in plasma samples. This bidimensional system used a restricted access media column (RP-8 ADS, 25 mm × 4 mm × 25 μM) in the first dimension and a core-shell Kinetex C18 (100 mm × 2, 1.7 mm × 1 μM) column in the second dimension, followed by detection in a mass spectrometer triple quadrupole (multiple reactions monitoring mode) operating in the positive mode. RP-8 ADS was used for trace enrichment of eCBs (reverse phase partitioning) and macromolecular matrix size exclusion; the core-shell column was used for the chromatographic separation. The column switching UHPLC-MS/MS method presented a linear range spanning from 0.1 ng mL -1 (LOQ) to 6 ng mL -1 for AEA and from 0.04 ng mL -1 (LOQ) to 10 ng mL -1 for 2-AG. Excluding the LLOQ values, the precision assays provided coefficients of variation lower than 8% and accuracy with relative standard error values lower than 14%. Neither carryover nor matrix effects were detected. This high-throughput column switching method compared to conventional methods is time saving as it involves fewer steps, consumes less solvent, and presents lower LLOQ. The column switching UHPLC-MS/MS method was successfully applied to determine AEA and 2-AG in plasma samples obtained from Alzheimer's disease patients. Graphical abstract A column switching ultra high-performance liquid chromatography-tandem mass spectrometry method using RP-8 ADS column and core shell column to determine endocannabinoids in plasma samples.

  11. Separation of the Components of a Commercial Analgesic Tablet: A Two-Week Sequence Comparing Purification by Two-Base Extraction and Column Chromatography

    Science.gov (United States)

    Revell, Kevin D.

    2011-01-01

    A new laboratory experiment is described in which students compare two benchtop separation methods to isolate the three active components of the commercial analgesic Excedrin. In the two-week sequence, aspirin, acetaminophen, and caffeine are separated using either a two-base liquid-liquid extraction or silica column chromatography. Students then…

  12. Post-column mobile phase adjustment: a strategy to eliminate the contradiction between liquid chromatography and mass spectrometry in the determination of flavonoids in rat plasma.

    Science.gov (United States)

    Zheng, Shirui; Ma, Zhiyuan; Han, Haixia; Ye, Jianfeng; Wang, Ruwei; Cai, Sheng; Zhou, Hui; Yu, Lushan; Zeng, Su; Jiang, Huidi

    2014-07-01

    Flavonoids are a group of important naturally occurring polyphenolic compounds with a wide range of biological effects. In this study, a sensitive liquid chromatography tandem mass spectrometry method was developed to simultaneously determine multiple active flavonoids, including quercetin (Que), kaempferol (Kae), apigenin (Api), isorhamnetin (Iso), luteolin (Lut), and naringenin (Nar), in rat plasma. To achieve a satisfied peak shape and LC separation, formic acid with the concentration between 0.05 and 0.2%, or in some case 5%, was generally used to acidify the LC mobile phase in reported studies. Here we found that even 0.05% formic acid could lead to strong mass signal suppression, and the absence of formic acid could reverse the signal suppression but cause serious peak tailing. There is an irreconcilable contradiction between liquid chromatography (LC) and mass spectrometry (MS). In order to simultaneously satisfy LC and MS, LC mobile phase with 0.00075% formic acid and post column mobile phase adjustment with 0.0677% ammonium solution in isopropanol were applied. Compared with the conventional method with mobile phase containing 0.05% formic acid, the mass signal response of Que, Kae, Api, Iso, Lut, Nar, and Oka increased 26.2, 18.6, 13.6, 23.5, 17.5, 15.6 and 15.4 fold, respectively. In addition, the post column mobile phase addition exhibited the better peak shape for the reduction of analytes longitudinal diffusion. The method has been fully validated according to FDA guidelines within the linear range between 0.328 ng mL⁻¹ and 168 ng mL⁻¹, and successfully applied to a pilot pharmacokinetic study of rats after administering 5.43 g kg⁻¹ Pollen of Brassica campestris. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Determination of 3-hydroxypropylmercapturic acid in urine by three column-switching high-performance liquid chromatography with electrochemical detection using a diamond electrode.

    Science.gov (United States)

    Higashi, Kyohei; Shibasaki, Mana; Kuni, Kyoshiro; Uemura, Takeshi; Waragai, Masaaki; Uemura, Kenichi; Igarashi, Kazuei; Toida, Toshihiko

    2017-09-29

    A three column-switching high-performance liquid chromatography (HPLC) using an electrochemical detector (ECD) equipped with a diamond electrode was established to determine 3-hydroxypropylmercapturic acid (3-HPMA) in urine. An extracted urine sample was consecutively fractionated using a strong anion-exchange column (first column) and a C8 column (second column) via a switching valve before application on an Octa Decyl Silyl (ODS) column (third column), followed by ECD analysis. The% recovery of 3-HPMA standard throughout the three-column process and limit of detection (LOD) were 94±1% and 0.1pmol, respectively. A solid phase extraction step is required for the sensitive analysis of 3-HPMA in urine by column-switching HPLC-ECD despite a decreased% recovery (55%) of urine sample spiked with 100pmol of 3-HPMA. To test the utility of our column-switching HPLC-ECD method, 3-HPMA levels of 27 urine samples were determined, and the correlation between HPLC-ECD and LC-Electrospray ionization (ESI)-MS/MS method was examined. As a result, the median values of μmol 3-HPMA/g Creatinine (Cre) in urine obtained by column-switching HPLC-ECD and LC-MS/MS were 2.19±2.12μmol/g Cre and 2.13±3.38μmol/g Cre, respectively, and the calibration curve (y=1.5171x-1.007) exhibited good linearity within a defined range (r 2 =0.907). These results indicate that the combination of column-switching HPLC and ECD is a powerful tool for the specific, reliable detection of 3-HPMA in urine. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Scale-up protein separation on stainless steel wide bore toroidal columns in the type-J counter-current chromatography.

    Science.gov (United States)

    Guan, Yue Hugh; Hewitson, Peter; van den Heuvel, Remco N A M; Zhao, Yan; Siebers, Rick P G; Zhuang, Ying-Ping; Sutherland, Ian

    2015-12-11

    Manufacturing high-value added biotech biopharmaceutical products (e.g. therapeutic proteins) requires quick-to-develop, GMP-compliant, easy-to-scale and cost effective preparatory chromatography technologies. In this work, we describe the construction and testing of a set of 5-mm inner diameter stainless steel toroidal columns for use on commercially available preparatory scale synchronous J-type counter-current chromatography (CCC) machinery. We used a 20.2m long column with an aqueous two-phase system containing 14% (w/w) PEG1000 and 14% (w/w) potassium phosphate at pH 7, and tested a sample loading of 5% column volume and a mobile phase flow rate of 20ml/min. We then satisfactorily demonstrated the potential for a weekly protein separation and preparation throughput of ca. 11g based on a normal weekly routine for separating a pair of model proteins by making five stacked injections on a single portion of stationary phase with no stripping. Compared to our previous 1.6mm bore PTFE toroidal column, the present columns enlarged the nominal column processing throughput by nearly 10. For an ideal model protein injection modality, we observed a scaling up factor of at least 21. The 2 scales of protein separation and purification steps were realized on the same commercial CCC device. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Evaluation and application of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry for complex sample analysis.

    Science.gov (United States)

    Denawaka, Chamila J; Fowlis, Ian A; Dean, John R

    2014-04-18

    An evaluation of static headspace-multicapillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS) has been undertaken to assess its applicability for the determination of 32 volatile compounds (VCs). The key experimental variables of sample incubation time and temperature have been evaluated alongside the MCC-GC variables of column polarity, syringe temperature, injection temperature, injection volume, column temperature and carrier gas flow rate coupled with the IMS variables of temperature and drift gas flow rate. This evaluation resulted in six sets of experimental variables being required to separate the 32 VCs. The optimum experimental variables for SHS-MCC-GC-IMS, the retention time and drift time operating parameters were determined; to normalise the operating parameters, the relative drift time and normalised reduced ion mobility for each VC were determined. In addition, a full theoretical explanation is provided on the formation of the monomer, dimer and trimer of a VC. The optimum operating condition for each VC calibration data was obtained alongside limit of detection (LOD) and limit of quantitation (LOQ) values. Typical detection limits ranged from 0.1ng bis(methylthio)methane, ethylbutanoate and (E)-2-nonenal to 472ng isovaleric acid with correlation coefficient (R(2)) data ranging from 0.9793 (for the dimer of octanal) through to 0.9990 (for isobutyric acid). Finally, the developed protocols were applied to the analysis of malodour in sock samples. Initial work involved spiking an inert matrix and sock samples with appropriate concentrations of eight VCs. The average recovery from the inert matrix was 101±18% (n=8), while recoveries from the sock samples were lower, that is, 54±30% (n=8) for sock type 1 and 78±24% (n=6) for sock type 2. Finally, SHS-MCC-GC-IMS was applied to sock malodour in a field trial based on 11 volunteers (mixed gender) over a 3-week period. By applying the SHS-MCC-GC-IMS database, four VCs were

  16. Temperature-based on-column solute focusing in capillary liquid chromatography reduces peak broadening from pre-column dispersion and volume overload when used alone or with solvent-based focusing.

    Science.gov (United States)

    Groskreutz, Stephen R; Horner, Anthony R; Weber, Stephen G

    2015-07-31

    On-column focusing is essential for satisfactory performance using capillary scale columns. On-column focusing results from generating transient conditions at the head of the column that lead to high solute retention. Solvent-based on-column focusing is a well-known approach to achieve this. Temperature-assisted on-column focusing (TASF) can also be effective. TASF improves focusing by cooling a short segment of the column inlet to a temperature that is lower than the column temperature during the injection and then rapidly heating the focusing segment to the match the column temperature. A troublesome feature of an earlier implementation of TASF was the need to leave the capillary column unpacked in that portion of the column inside the fitting connecting it to the injection valve. We have overcome that problem in this work by packing the head of the column with solid silica spheres. In addition, technical improvements to the TASF instrumentation include: selection of a more powerful thermo-electric cooler to create faster temperature changes and electronic control for easy incorporation into conventional capillary instruments. Used in conjunction with solvent-based focusing and with isocratic elution, volumes of paraben samples (esters of p-hydroxybenzoic acid) up to 4.5-times the column liquid volume can be injected without significant bandspreading due to volume overload. Interestingly, the shapes of the peaks from the lowest volume injections that we can make, 30nL, are improved when using TASF. TASF is very effective at reducing the detrimental effects of pre-column dispersion using isocratic elution. Finally, we show that TASF can be used to focus the neuropeptide galanin in a sample solvent with elution strength stronger than the mobile phase. Here, the stronger solvent is necessitated by the need to prevent peptide adsorption prior to and during analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Detection of peptides by precolumn derivatization with biuret reagent and preconcentration on capillary liquid chromatography columns with electrochemical detection.

    Science.gov (United States)

    Shen, H; Witowski, S R; Boyd, B W; Kennedy, R T

    1999-03-01

    The separation and detection of biuret complexes of neuropeptides by capillary liquid chromatography with electrochemical detection was explored. Capillaries of 25-micron inner diameter packed with base-resistant, polymer-based reversed-phase particles were used for separation, and C-fiber electrodes were used for detection. Detection at the C-fiber electrode was found to have some differences in relative sensitivity for peptides compared to glassy carbon electrodes used previously. On-column preconcentration of preformed complexes allowed up to 1-microL samples to be injected with minimal band broadening resulting in a 100-fold improvement in concentration detection limit with no effect on mass detection limit. Concentration detection limits ranged from 5 to 59 pM, depending upon the peptide, corresponding to 5-59 amol injected. The low concentration detection limit was possible because of minimal baseline disturbances, minimal formation of unwanted products, and high efficiency of complex formation associated with biuret derivatization. The method was applied to determination of vasopressin and bradykinin in dialysates collected with 5-min sampling frequency from the rat supraoptic nucleus.

  18. Impact of injection solvent composition on protein identification in column-switching chip-liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Houbart, V; Cobraiville, G; Nys, G; Merville, M-P; Fillet, M

    2016-05-06

    In shotgun proteomics, the gold standard technique is reversed-phase liquid chromatography coupled to mass spectrometry. Many researches have been carried out to study the effects on identification performances of chromatographic parameters such as the stationary phase and column dimensions, mobile phase composition and flow rate, as well as the gradient slope and length. However, little attention is usually paid to the injection solvent composition. In this study, we investigated the effect of the injection solvent on protein identification parameters (number of distinct peptides, amino acid coverage and MS/MS search score) as well as sensitivity. Tryptic peptides from six different proteins, covering a wide range of physicochemical properties, were employed as training set. Design of experiments was employed as a tool to highlight the factors related to the composition of the injection solvent that significantly influenced the obtained results. Optimal results for the training set were applied to analysis of more complex samples. The experiments pointed out optimising the composition of the injection solvent had a strong beneficial effect on all the considered responses. On the basis of these results, an approach to determine optimal conditions was proposed to maximise the protein identification performances and detection sensitivity. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Determination of trace inorganic anions in weak acids by single-pump column-switching ion chromatography.

    Science.gov (United States)

    Zhu, Haibao; Chen, Huadong; Zhong, Yingying; Ren, Dandan; Qian, Yaling; Tang, Hongfang; Zhu, Yan

    2010-08-01

    Ion chromatography has been proposed for the determination of three common inorganic anions (chloride, nitrate, and sulfate) in nine weak acids (tartaric acid, citric acid, formic acid, acetic acid, metacetonic acid, butyric acid, butanedioic acid, hexafluorophosphoric acid, and salicylic acid) using a single pump, two valves, a single eluent, and a single conductivity detector. The present system uses ion exclusion, concentrator, and anion-exchange columns connected in series via 6-port and 10-port valves in a Dionex ICS-2100 ion chromatograph. The valves were switched for the determination of three inorganic anions from weak acids in a single chromatographic run. Sample matrices of weak acids with a series of concentrations can be investigated. Complete separations of the previously mentioned anions are demonstrated within 40 min. Under the optimum conditions, the relative standard deviation values ranged from 1.3 to 3.8%. The detection limits of the three inorganic anions (S/N = 3) were in the range of 0.3-1.7 microg/L. The recoveries were in the range of 75.2-117.6%. With this system, automation for routine analysis, short analysis time, and low cost can be achieved.

  20. A microfluidic device for preparing next generation DNA sequencing libraries and for automating other laboratory protocols that require one or more column chromatography steps.

    Science.gov (United States)

    Tan, Swee Jin; Phan, Huan; Gerry, Benjamin Michael; Kuhn, Alexandre; Hong, Lewis Zuocheng; Min Ong, Yao; Poon, Polly Suk Yean; Unger, Marc Alexander; Jones, Robert C; Quake, Stephen R; Burkholder, William F

    2013-01-01

    Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation.

  1. Evaluation of 1.0 mm i.d. column performances on ultra high pressure liquid chromatography instrumentation.

    Science.gov (United States)

    Lestremau, François; Wu, Di; Szücs, Roman

    2010-07-23

    The present study focuses on the evaluation of 1.0 mm i.d. (internal diameter) columns on a commercial Ultra-High Pressure system. These systems have been developed specifically to operate columns with small volumes, typically 2.1 mm i.d., by reducing extra-column volume dispersion. The use of columns with smaller i.d. results in a reduced solvent consumption and required sample volume. The evaluation of the columns was carried out with samples containing neutral and pharmaceutical compounds. In isocratic mode, the extra-column volume produced additional band broadening leading to poor performances compared to equivalent 2.1 mm i.d. columns. By increasing the length of the column, the influence of the extra-column bandspreading could be reduced and 75,000 plates were obtained when four columns were coupled. In gradient mode, the effect of the extra-column contribution on efficiency was limited and about 80% of the performance of the 2.1 mm i.d. columns was obtained. Optimum conditions in gradient mode were further investigated by changing flow rate, gradient time and column length. A different approach of the calculation of peak capacity was also considered for the comparison of the influence of these different parameters. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  2. A study of retention characteristics and quality control of nutraceuticals containing resveratrol and polydatin using fused-core column chromatography.

    Science.gov (United States)

    Fibigr, Jakub; Šatínský, Dalibor; Solich, Petr

    2016-02-20

    A new high-performance liquid chromatography method using fused-core column for fast separation of resveratrol and polydatin has been developed and used for quality control of nutraceuticals with resveratrol and polydatin content. Retention characteristics (log k) were studied under different conditions on C-18, RP-Amide C-18, Phenyl-hexyl, Pentafluorophenyl (F5) and Cyano stationary phases for both compounds. The effect of the volume fraction of acetonitrile on a retention factors log k of resveratrol and polydatin were evaluated. The optimal separation conditions for resveratrol, polydatin and internal standard p-nitrophenol were found on the fused-core column Ascentis Express ES-Cyano (100×3.0mm), particle size 2.7μm, with mobile phase acetonitrile/water solution with 0.5% acetic acid pH 3 (20:80, v/v) at a flow rate of 1.0mL/min and at 60°C. The detection wavelength was set at 305nm. Under the optimal chromatographic conditions, good linearity with regression coefficients in the range (r=0.9992-0.9998; n=10) for both compounds was achieved. Commercial samples of nutraceuticals were extracted with methanol using ultrasound bath for 15min. A 5μL sample volume of the filtered solution was directly injected into the HPLC system. Accuracy of the method defined as a mean recovery was in the range 83.2-107.3% for both nutraceuticals. The intraday method precision was found satisfactory and relative standard deviations of sample analysis were in the range 0.8-4.7%. The developed method has shown high sample throughput during sample preparation process, modern separation approach, and short time (3min) of analysis. The results of study showed that the declared content of resveratrol and polydatin varied widely in different nutraceuticals according the producers (71.50-115.00% of declared content). Copyright © 2015 Elsevier B.V. All rights reserved.

  3. P61-S Multidimensional Liquid Chromatography of Proteins Using Monolithic Weak Anion Exchange and Reversed-Phase Columns

    OpenAIRE

    Sneekes, E.; van Ling, R.; de Haan, B.; Dolman, B.; Swart, R.; van Gils, M.

    2007-01-01

    Recent developments in monolithic column technology have yielded significant improvements in the biopolymer analysis field. Monolithic columns offer several advantages over particulate columns due to their macroporous structure, which provides fast mass transfer, low back pressure and high resolution. Polystyrene divinylbenzene (PS-DVB) monolithic columns are chemically inert; they offer high pH stability and excellent chromatographic performance in reversed-phase LC. While the application of...

  4. Novel on-line column extraction apparatus coupled with binary peak focusing for high-performance liquid chromatography determination of rifampicin in human plasma: a strategy for therapeutic drug monitoring.

    Science.gov (United States)

    Li, Wei; Peng, Min; Long, Minghui; Qiu, Ximin; Yang, Liping

    2014-12-01

    In order to develop a method that is completely suitable for the routine therapeutic drug monitoring, a sensitive and fully automated on-line column extraction apparatus in combination with high-performance liquid chromatography allowing binary peak focusing was developed and validated for the determination of rifampicin in human plasma. Rifapentine was used as an internal standard. The analytical cycle started with the injection of 100 μL of the sample pretreated by protein precipitation in a Venusil SCX extraction column. After the elution, the analytes were transferred and concentrated in an Xtimate C18 trap column. Finally, the trapped analytes were separated by an Xtimate C18 analytical column and were analyzed by an ultraviolet detector at 336 nm. With this new strategy, continuous on-line analysis of the compounds was successfully performed. The method showed excellent performance for the analysis of rifampicin in plasma samples, including calibration curve linearity (All r were larger than 0.9996), sensitivity (lowest limit of quantification was 0.12 μg/mL), method accuracy (within 6.6% in terms of relative error), and precision (relative standard deviations of intra- and interday precision were less than 7.8%). These results demonstrated that the simple, reliable, and automatic method based on on-line column extraction and binary peak focusing is a promising approach for therapeutic drug monitoring in complex biomatrix samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Determination of aspirin by pre-column transacetylation reaction of 3-aminophenol and reversed-phase high-performance liquid chromatography: simultaneous determination of aspirin, acetaminophen, and caffeine.

    Science.gov (United States)

    Verma, K K; Sanghi, S K; Jain, A; Gupta, D

    1987-07-01

    The accuracy of the measurement of aspirin by high-performance liquid chromatography (HPLC) is reduced by its hydrolysis into salicylic and acetic acids during sample preparation. The ready and quantitative transacetylation of 3-aminophenol by aspirin, giving 3-hydroxyacetanilide (which is stable), has been utilized as a pre-column reaction for the determination of aspirin either alone or in the presence of acetaminophen and caffeine by reversed-phase HPLC.

  6. The use of phospholipid modified column for the determination of lipophilic properties in high performance liquid chromatography.

    Science.gov (United States)

    Godard, Tal; Grushka, Eli

    2011-03-04

    A new chromatographic stationary phase obtained by coating a reversed phase amide column with phosphatidylcholine based liposomes solution to yield a phospholipid modified column (PLM). The modification is achieved by the dynamic coating method which recycles the coating solution through the column in a closed loop for a period of 24 h. The chromatographic properties of the new column have changed significantly as compared to the original amide column due to the phospholipid coating. A good correlation was observed between n-octanol/water logP values and the logarithm of the retention factor obtained on the PLM column for a large number of solutes. In addition the PLM column was characterized using the linear solvation energy relationship (LSER). The values of the LSER system constants for the PLM column were calculated and were found to be very close to those of the n-octanol/water extraction system thus suggesting that the PLM column can be used for the estimation of n-octanol/water partition coefficient and serve as a possible alternative to the shake-flask method for lipophilicity determination. In addition, the results suggest that the PLM column can provide an alternative to other phospholipid-based column such as the IAM and the DPC columns. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Preparation and evaluation of 400μm I.D. polymer-based hydrophilic interaction chromatography monolithic columns with high column efficiency.

    Science.gov (United States)

    Liu, Chusheng; Li, Haibin; Wang, Qiqin; Crommen, Jacques; Zhou, Haibo; Jiang, Zhengjin

    2017-08-04

    The quest for higher column efficiency is one of the major research areas in polymer-based monolithic column fabrication. In this research, two novel polymer-based HILIC monolithic columns with 400μm I.D.×800μm O.D. were prepared based on the thermally initiated co-polymerization of N,N-dimethyl-N-(3-methacrylamidopropyl)-N-(3-sulfopropyl) ammonium betaine (SPP) and ethylene glycol dimethacrylate (EDMA) or N,N'-methylenebisacrylamide (MBA). In order to obtain a satisfactory performance in terms of column permeability, mechanical stability, efficiency and selectivity, the polymerization parameters were systematically optimized. Column efficiencies as high as 142, 000 plates/m and 120, 000 plates/m were observed for the analysis of neutral compounds at 0.6mm/s on the poly(SPP-co-MBA) and poly(SPP-co-EDMA) monoliths, respectively. Furthermore, the Van Deemter plots for thiourea on the two monoliths were compared with that on a commercial silica based ZIC-HILIC column (3.5μm, 200Å, 150mm×300μm I.D.) using ACN/H 2 O (90/10, v/v) as the mobile phase at room temperature. It was noticeable that the Van Deemter curves for both monoliths, particularly the poly(SPP-co-MBA) monolith, are significantly flatter than that obtained for the ZIC-HILIC column, which indicates that in spite of their larger internal diameters, they yield better overall efficiency, with less peak dispersion, across a much wider range of usable linear velocities. A clearly better separation performance was also observed for nucleobases, nucleosides, nucleotides and small peptides on the poly(SPP-co-MBA) monolith compared to the ZIC-HILIC column. It is particularly worth mentioning that these 400μm I.D. polymer-based HILIC monolithic columns exhibit enhanced mechanical strength owing to the thicker capillary wall of the fused-silica capillaries. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Physical properties and structure of fine core-shell particles used as packing materials for chromatography Relationships between particle characteristics and column performance.

    Science.gov (United States)

    Gritti, Fabrice; Leonardis, Irene; Abia, Jude; Guiochon, Georges

    2010-06-11

    The recent development of new brands of packing materials made of fine porous-shell particles, e.g., Halo and Kinetex, has brought great improvements in potential column efficiency, demanding considerable progress in the design of chromatographic instruments. Columns packed with Halo and Kinetex particles provide minimum values of their reduced plate heights of nearly 1.5 and 1.2, respectively. These packing materials have physical properties that set them apart from conventional porous particles. The kinetic performance of 4.6mm I.D. columns packed with these two new materials is analyzed based on the results of a series of nine independent and complementary experiments: low-temperature nitrogen adsorption (LTNA), scanning electron microscopy (SEM), inverse size-exclusion chromatography (ISEC), Coulter counter particle size distributions, pycnometry, height equivalent to a theoretical plate (HETP), peak parking method (PP), total pore blocking method (TPB), and local electrochemical detection across the column exit section (LED). The results of this work establish links between the physical properties of these superficially porous particles and the excellent kinetic performance of columns packed with them. It clarifies the fundamental origin of the difference in the chromatographic performances of the Halo and the Kinetex columns. Copyright 2010 Elsevier B.V. All rights reserved.

  9. Quality by design: a systematic and rapid liquid chromatography and mass spectrometry method for eprosartan mesylate and its related impurities using a superficially porous particle column.

    Science.gov (United States)

    Kalariya, Pradipbhai D; Kumar Talluri, Murali V N; Gaitonde, Vinay D; Devrukhakar, Prashant S; Srinivas, Ragampeta

    2014-08-01

    The present work describes the systematic development of a robust, precise, and rapid reversed-phase liquid chromatography method for the simultaneous determination of eprosartan mesylate and its six impurities using quality-by-design principles. The method was developed in two phases, screening and optimization. During the screening phase, the most suitable stationary phase, organic modifier, and pH were identified. The optimization was performed for secondary influential parameters--column temperature, gradient time, and flow rate using eight experiments--to examine multifactorial effects of parameters on the critical resolution and generated design space representing the robust region. A verification experiment was performed within the working design space and the model was found to be accurate. This study also describes other operating features of the column packed with superficially porous particles that allow very fast separations at pressures available in most liquid chromatography instruments. Successful chromatographic separation was achieved in less than 7 min using a fused-core C18 (100 mm × 2.1 mm, 2.6 μm) column with linear gradient elution of 10 mM ammonium formate (pH 3.0) and acetonitrile as the mobile phase. The method was validated for specificity, linearity, accuracy, precision, and robustness in compliance with the International Conference on Harmonization Q2 (R1) guidelines. The impurities were identified by liquid chromatography with mass spectrometry. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Capillary ion chromatography with on-column focusing for ultra-trace analysis of methanesulfonate and inorganic anions in limited volume Antarctic ice core samples.

    Science.gov (United States)

    Rodriguez, Estrella Sanz; Poynter, Sam; Curran, Mark; Haddad, Paul R; Shellie, Robert A; Nesterenko, Pavel N; Paull, Brett

    2015-08-28

    Preservation of ionic species within Antarctic ice yields a unique proxy record of the Earth's climate history. Studies have been focused until now on two proxies: the ionic components of sea salt aerosol and methanesulfonic acid. Measurement of the all of the major ionic species in ice core samples is typically carried out by ion chromatography. Former methods, whilst providing suitable detection limits, have been based upon off-column preconcentration techniques, requiring larger sample volumes, with potential for sample contamination and/or carryover. Here, a new capillary ion chromatography based analytical method has been developed for quantitative analysis of limited volume Antarctic ice core samples. The developed analytical protocol applies capillary ion chromatography (with suppressed conductivity detection) and direct on-column sample injection and focusing, thus eliminating the requirement for off-column sample preconcentration. This limits the total sample volume needed to 300μL per analysis, allowing for triplicate sample analysis with Application to composite ice-core samples is demonstrated, with coupling of the capillary ion chromatograph to high resolution mass spectrometry used to confirm the presence and purity of the observed methanesulfonate peak. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Enantiomeric quantification of (S)-(+)-methamphetamine in urine by an immunoaffinity column and liquid chromatography-electrospray-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lua, Ahai C. [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China); Sutono, Yenny [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China); Chou, T.-Y. [Department of Laboratory Medicine and Biotechnology and Graduate Institute of Medical Biotechnology, Tzu Chi University, 701, Chung Yang Road Section 3, Hualien, 970, Taiwan (China)]. E-mail: cty@mail.tcu.edu.tw

    2006-08-18

    A method using an immunoaffinity column (IAC) and liquid chromatography-electrospray ionization mass spectrometry (LC/MS) for on-line detecting the presence of MA in the effluent was developed for the quantitative and enantiomeric determination of (S)-(+)-methamphetamine (D-MA) in urine. The IAC was made in our laboratory and utilized in the LC/MS to simultaneously extract and separate enantiomers of MA from urine samples. An aqueous ammonium acetate buffer was used as the mobile phase. Urine samples were spiked with racemic deuterated methamphetamine (MA-d{sub 14}) as internal standard (IS), filtered through a membrane, and injected into the LC/MS without any further pre-treatment. Protonated molecular ion of MA and MA-d{sub 14} (m/z 150 and 164) were isolated and further fragmented, the respective product ions, m/z 119 and 130, were collected for quantitative determination. This is an improvement of our previous method (A.C. Lua, Tsong-Yung Chou, J. Chromatogr. A 967 (2002) 191). In the previous method, MA was separated with HPLC, the efflux was fractionated and each fraction was either determined with an immunoassay or GC/MS. Monitoring of MA in the efflux is tedious and time consuming. Urine samples spiked with different concentrations of D-MA were measured by this method. A linear relationship exists in the 150-1050 ng/mL range, and the detection limit (defined as signal-to-noise ratio 3) of D-MA was determined to be 18 ng/mL. The linearity of the method for D-MA can be described by the equation (Y = 1.415 x 10{sup -3} X + 0.034, correlation coefficient: r {sup 2} = 0.999). Within run, accuracy and precision (n = 6, relative error: -7.2 to +4.0% and relative standard deviation: 3.8-9.3%) of the method are fairly good.

  12. The synthesis of surface-glycosylated porous monolithic column via aqueous two-phase graft copolymerization and its application in capillary-liquid chromatography.

    Science.gov (United States)

    Xiong, Xiyue; He, Haiqin; Shu, Yan; Li, Yuxin; Yang, Zihui; Chen, Yingzhuang; Ma, Ming; Chen, Bo

    2016-12-01

    A facile, flexible process was developed for the preparation of surface-glycosylated porous monolithic columns via aqueous two-phase graft copolymerization of polyethylene glycol diacrylate (PEGDA) and water-soluble dextran (dextran sulfate). The formation of poly(PEGDA) porous skeletons and surface glycosylation were achieved via a one-step process without pre-modification of the dextran. The synthesis conditions were thoroughly optimized. The optimal monolithic column exhibited a large dry state surface area (greater than 400m 2 /g), and it was evaluated as a hydrophilic liquid chromatography (HILIC) stationary phase. A typical HILIC mechanism was observed at high organic solvent content (≥65% acetonitrile). In addition, the resulting monolithic column demonstrated the potential use in analysis of complex biological sample and enviroment water. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. On-line immunoaffinity column-liquid chromatography-tandem mass spectrometry method for trace analysis of diuron in wastewater treatment plant effluent sample.

    Science.gov (United States)

    Zhang, Xiuli; Martens, Dieter; Krämer, Petra M; Kettrup, Antonius A; Liang, Xinmiao

    2006-11-10

    An on-line immunoaffinity column with liquid chromatography/tandem mass spectrometry (IAC-LC-MS/MS) method for the determination of diuron in water matrices was described. This method used a sol-gel immunoaffinity column (20 mm x 4 mm I.D.) for on-line sample cleanup and enrichment, a monolithic analytical column (100 mm x 4.6 mm I.D.) for separation, and a triple quadrupole mass spectrometer for quantitation. The major challenges for the on-line set-up were discussed. The optimized on-line protocol was emphasized by the fact that low limit of quantitation (LOQ) of 1.0 ng/L was achieved with only 2.5-mL sample. In addition, a satisfactory accuracy ( approximately 90% of recovery) and precision (effect, the on-line IAC-LC-MS/MS analysis method can reliably determine diuron in wastewater treatment plant effluent sample.

  14. Determination of lansoprazole enantiomers in dog plasma by column-switching liquid chromatography with tandem mass spectrometry and its application to a preclinical pharmacokinetic study.

    Science.gov (United States)

    Wang, Hao; Sun, Yantong; Meng, Xiangjun; Yang, Bo; Wang, Jian; Yang, Yan; Gu, Jingkai

    2015-09-01

    Lansoprazole, a selective proton pump inhibitor, has a chiral benzimidazole sulfoxide structure and is used for the treatment of gastric acid hypersecretory related diseases. To investigate its stereoselective pharmacokinetics, a column-switching liquid chromatography with tandem mass spectrometry method was developed for the determination of lansoprazole enantiomers in dog plasma using (+)-pantoprazole as an internal standard. After a simple protein precipitation procedure with acetonitrile, matrix components left behind after sample preparation were further eliminated from the sample by reversed-phase chromatography on a C18 column. The fluent was fed to a chiral column for the separation of lansoprazole enantiomers. Baseline separation of lansoprazole enantiomers was achieved on a Chiralcel OZ-RH column using acetonitrile/0.1% formic acid in water (35:65, v/v) as the mobile phase at 40°C. The linearity of the calibration curves ranged from 3 to 800 ng/mL for each enantiomer. Intra- and inter-day precisions ranged from 2.1 to 7.3% with an accuracy of ±1.7% for (+)-lansoprazole, and from 1.6 to 6.9% with an accuracy of ±3.5% for (-)-lansoprazole, respectively. The validated method was successfully applied for the stereoselective pharmacokinetic study of lansoprazole in beagle dog after intravenous infusion. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Optimization of gas chromatography using short glass capillary column with mass spectrometry for identification and evaluation of commercial heavy alkylbenzene structures.

    Science.gov (United States)

    Ghoreishi, S M; Beiggy, M; Mazloum Ardekani, M

    2003-04-01

    Heavy alkylbenzene (HAB) is one of the by-products when producing linear alkylbenzene (LAB). Identification of the fine structures of HAB is difficult because of its complex structure and high boiling point. The gas chromatography/mass spectrometry (GC/MS) technique with a short glass capillary column is the best method applicable to analysis of high-boiling and thermally labile compounds. The column efficiency is evaluated on the basis of Van Deemter curves. The experimental results show that the reduction in the optimum column efficiency for a short glass capillary column occurs along with a reduction in effective theoretical plates. A second important result is that the shift in the value of the flow velocity is related to the optimum point in height equivalent theoretical plate (HETP). The flow velocity is higher than that of conventional gas chromatography(GC). The optimized conditions were used to analyse HAB produced through the hydrogen fluoride (HF) alkylation process. The results show acceptable relative separation of a product in an extended boiling point range. The optimized conditions were also used to analyse three other special samples supplied by BASF company's AlCl(3 )alkylation process and to approve the previous structures. The results also show that HAB from Iran Chemical Industries Investment Company (ICIIC) produced through LAB complex consists of an additional part and has more linearity than the other three samples of HAB obtained from BASF.

  16. Comparison of high-performance liquid chromatography separation of red wine anthocyanins on a mixed-mode ion-exchange reversed-phase and on a reversed-phase column.

    Science.gov (United States)

    Vergara, Carola; Mardones, Claudia; Hermosín-Gutiérrez, Isidro; von Baer, Dietrich

    2010-09-03

    Anthocyanins, which confer the characteristic color to red wine, can be used as markers to classify wines according to the grape variety. It is a complex separation that requires very high chromatographic efficiency, especially in the case of aged red wines, due to the formation of pyranoanthocyanins. A coelution between these kinds of compounds can affect the R(ac/coum) ratio of aged wines, and might lead to false results when classifying the wine variety. In 2007, the use of a novel mixed-mode ion-exchange reversed-phase column was reported to separate anthocyanins extracted from grapes of Vitis labrusca with different selectivity than C-18 columns. In the present work, the separation of anthocyanins including pyranoanthocyanins in young and aged Cabernet Sauvignon wines and other varieties is evaluated. The most interesting contributions of this research are the different elution order and selectivity obtained for anthocyanins and pyranoanthocyanins (only formed in wine), compared with those observed in C-18 stationary phases. Also interesting is the separation of the polymeric fraction, which elutes as a clearly separated peak at the chromatogram's end. However, a comparison with a high efficiency C-18 column with the same dimensions and particle size demonstrated that the tested mixed-mode column shows broader peaks with a theoretical plate number below 8000, for malvidin-3-glucoside peak, while it can be up to 10 times higher for a high efficiency C-18 column, depending on the column manufacturer. Under the tested conditions, in mixed-mode phase, the analysis time is almost twice that of a C-18 column with the same dimensions and particle size. A mixed-mode phase with increased efficiency should provide an interesting perspective for separation of anthocyanins in wine, due to its improved selectivity, combined with a useful role in a second-dimension separation in preparative anthocyanin chromatography. 2010 Elsevier B.V. All rights reserved.

  17. Relating pressure tuned coupled column ensembles with the solvation parameter model for tunable selectivity in gas chromatography.

    Science.gov (United States)

    Sharif, Khan M; Kulsing, Chadin; Chin, Sung-Tong; Marriott, Philip J

    2016-07-15

    The differential pressure drop of carrier gas by tuning the junction point pressure of a coupled column gas chromatographic system leads to a unique selectivity of the overall separation, which can be tested using a mixture of compounds with a wide range of polarity. This study demonstrates a pressure tuning (PT) GC system employing a microfluidic Deans switch located at the mid-point of the two capillary columns. This PT system allowed variations of inlet-outlet pressure differences of the two columns in a range of 52-17psi for the upstream column and 31-11psi for the downstream column. Peak shifting (differential migration) of compounds due to PT difference are related to a first order regression equation in a Plackett-Burman factorial study. Increased first (upstream) column pressure drop makes the second column characteristics more significant in the coupled column retention behavior, and conversely increased second (downstream) column pressure drop makes the first column characteristics more apparent; such variation can result in component swapping between polar and non-polar compounds. The coupled column system selectivity was evaluated in terms of linear solvation energy relationship (LSER) parameters, and their relation with different pressure drop effects has been constructed by applying multivariate principle component analysis (PCA). It has been found that the coupled column PT system descriptors provide a result that shows a clear clustering of different pressure settings, somewhat intermediate between those of the two commercial columns. This is equivalent to that obtained from a conventional single-column GC analysis where the interaction energy contributed from the stationary phases can be significantly adjusted by choice of midpoint PT. This result provides a foundation for pressure differentiation for selectivity enhancement. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of chlorinated pesticides in aquatic tissue by capillary-column gas chromatography with electron-capture detection

    Science.gov (United States)

    Leiker, Thomas J.; Madsen, J.E.; Deacon, J.R.; Foreman, W.T.

    1995-01-01

    A method for the determination of chlorinated organic compounds in aquatic tissue by dual capillary-column gas chromatography with electron-capture detection is described. Whole-body-fish or corbicula tissue is homogenized, Soxhlet extracted, lipid removed by gel permeation chromatography, and fractionated using alumina/silica adsorption chromatography. The extracts are analyzed by dissimilar capillary-column gas chromatography with electron-capture detection. The method reporting limits are 5 micrograms per kilogram (μg/kg) for chlorinated compounds, 50 μg/kg for polychlorinated biphenyls, and 200 μg/kg for toxaphene.

  19. Determination of Wastewater Compounds in Whole Water by Continuous Liquid-Liquid Extraction and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Zaugg, Steven D.; Smith, Steven G.; Schroeder, Michael P.

    2006-01-01

    A method for the determination of 69 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals on aquatic organisms in wastewater. This method also is useful for evaluating the effects of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are indicators of wastewater or have endocrine-disrupting potential. These compounds include the alkylphenol ethoxylate nonionic surfactants, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Wastewater compounds in whole-water samples were extracted using continuous liquid-liquid extractors and methylene chloride solvent, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 0.5 microgram per liter averaged 72 percent ? 8 percent relative standard deviation. The concentration of 21 compounds is always reported as estimated because method recovery was less than 60 percent, variability was greater than 25 percent relative standard deviation, or standard reference compounds were prepared from technical mixtures. Initial method detection limits averaged 0.18 microgram per liter. Samples were preserved by adding 60 grams of sodium chloride and stored at 4 degrees Celsius. The laboratory established a sample holding-time limit prior to sample extraction of 14 days from the date of collection.

  20. Development and characterization of the α3β4α5 nicotinic receptor cellular membrane affinity chromatography column and its application for on line screening of plant extracts.

    Science.gov (United States)

    Ciesla, L; Okine, M; Rosenberg, A; Dossou, K S S; Toll, L; Wainer, I W; Moaddel, R

    2016-01-29

    The α3β4α5 nAChR has been recently shown to be a useful target for smoking cessation pharmacotherapies. Herein, we report on the development and characterization of the α3β4α5 nicotinic receptor column by frontal displacement chromatography. The binding affinity of the nicotine and minor alkaloids found in tobacco smoke condensates were determined for both the α3β4 and α3β4α5 nicotinic receptors. It was demonstrated that while no subtype selectivity was observed for nicotine and nornicotine, anabasine was selective for the α3β4α5 nicotinic receptor. The non-competitive inhibitor binding site was also studied and it was demonstrated while mecamylamine was not selective between subtypes, buproprion showed subtype selectivity for the α3β4 nicotinic receptor. The application of this methodology to complex mixtures was then carried out by screening aqueous-alcoholic solutions of targeted plant extracts, including Lycopodium clavatum L. (Lycopodiaceae) and Trigonella foenum graecum L. (Fabaceae) against both the α3β4 and α3β4α5 nAChRs. Published by Elsevier B.V.

  1. Properties of hydrodynamic J-type countercurrent chromatography for protein separation using aqueous two-phase systems: With special reference to constructing conical columns.

    Science.gov (United States)

    Ding, Jianjian; Li, Shifei; Zhao, Yuqing; Guan, Yue Hugh; Deng, Li; Deng, Qiuyun

    2017-05-26

    Protein separation using hydrodynamic countercurrent chromatography (CCC), where low backpressure is inherent, is more challenging, more time consuming and more costly when compared with separating small molecules. The most hopeful approach is to rationally design suitable columns for already commercialized J-type CCC machinery. By comparing 3 column geometries (3D helix, 2D spiral and 3D cone), we firstly constructed the mechanical model tailored to the conical column on J-type CCC using aqueous two-phase system (ATPS) on protein separation. Aimed at mechanistically understanding hydrodynamic CCC, we then developed a semi-quantitative model to account for contributions of both hydrodynamic and hydrostatic forces to stationary phase retention, and have subsequently compared the modelling outcomes with experimental results. We practiced a methodology to delineate both phase mixing and stationary phase retention before committing to physically constructing CCC columns. Following theoretical analyses, we finally constructed conical columns for J-type CCC. Using model proteins (myoglobin and lysozyme) and with 2 ATPSs containing PEG1000 and phosphate, sound protein separation has been achieved (resolution reaches 1.5-2.0 and stationary phase retention also exceeds 40%) for the selected ATPSs and under a varied level of sample volumes and loadings. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Determination of gas-liquid partition coefficients of several organic solutes in trihexyl(tetradecyl)phosphonium bromide using capillary gas chromatography columns.

    Science.gov (United States)

    Ronco, Nicolás R; Menestrina, Fiorella; Romero, Lílian M; Castells, Cecilia B

    2017-06-09

    In this paper, we report gas-liquid partition constants for thirty-five volatile organic solutes in the room temperature ionic liquid trihexyl(tetradecyl)phosphonium bromide measured by gas-liquid chromatography using capillary columns. The relative contribution of gas-liquid partition and interfacial adsorption to retention was evaluated through the use of columns with different the phase ratio. Four capillary columns with exactly known phase ratios were constructed and employed to measure the solute retention factors at four temperatures between 313.15 and 343.15K. The partition coefficients were calculated from the slopes of the linear regression between solute retention factors and the reciprocal of phase ratio at a given temperature according to the gas-liquid chromatographic theory. Gas-liquid interfacial adsorption was detected for a few solutes and it has been considered for the calculations of partition coefficient. Reliable solute's infinite dilution activity coefficients can be obtained when retention data are determined by a unique partitioning mechanism. The partial molar excess enthalpies at infinite dilution have been estimated from the dependence of experimental values of solute activity coefficients with the column temperature. A thorough discussion of the uncertainties of the experimental measurements and the main advantages of the use of capillary columns to acquire the aforementioned relevant thermodynamic information was performed. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Simultaneous analysis of perfluoroalkyl and polyfluoroalkyl substances including ultrashort-chain C2 and C3 compounds in rain and river water samples by ultra performance convergence chromatography.

    Science.gov (United States)

    Yeung, Leo W Y; Stadey, Christopher; Mabury, Scott A

    2017-11-03

    An analytical method using ultra performance convergence chromatography (UPC 2 ) coupled to a tandem mass spectrometer operated in negative electrospray mode was developed to measure perfluoroalkyl and polyfluoroalkyl substances (PFASs) including the ultrashort-chain PFASs (C2-C3). Compared to the existing liquid chromatography tandem mass spectrometry method using an ion exchange column, the new method has a lower detection limit (0.4pg trifluoroacetate (TFA) on-column), narrower peak width (3-6s), and a shorter run time (8min). Using the same method, different classes of PFASs (e.g., perfluoroalkyl sulfonates (PFSAs) and perfluorinated carboxylates (PFCAs), perfluorinated phosphonates (PFPAs) and phosphinates (PFPiAs), polyfluoroalkyl phosphate diesters (diPAPs)) can be measured in a single analysis. Rain (n=2) and river water (n=2) samples collected in Toronto, ON, were used for method validation and application. Results showed that short-chain PFAS (C2-C7 PFCAs and C4 PFSA) contributed to over 80% of the detectable PFASs in rain samples and the C2-C3 PFASs alone accounted for over 40% of the total. Reports on environmental levels of these ultrashort-chain PFASs are relatively scarce. Relatively large contribution of these ultrashort-chain PFASs to the total PFASs indicate the need to include the measurement of short-chain PFASs, especially C2 and C3 PFASs, in environmental monitoring. The sources of TFA and other short-chain PFASs in the environment are not entirely clear. The newly developed analytical method may help further investigation on the sources and the environmental levels of these ultrashort-chain PFASs. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. On-line sample enrichment-capillary gas chromatography of aqueous samples using geometrically deformed open-tubular extraction columns.

    NARCIS (Netherlands)

    Mol, H.G.J.; Janssen, H.G.; Cramers, C.A.; Brinkman, U.A.T.

    1996-01-01

    The effect of geometrical deformation of open‐tubular extraction columns on peak dispersion of retained solutes is evaluated. By coiling or stitching of the columns peak dispersion is decreased, with a factor of two and more than five, respectively, due to secondary flow enhanced radial dispersion.

  5. Pressure-driven reverse-phase liquid chromatography separations in ordered non-porous pillar array columns

    NARCIS (Netherlands)

    de Malsche, Wim; Eghbali, Hamed; Clicq, David; Vangelooven, Joris; Gardeniers, Johannes G.E.; Desmet, Gert

    2007-01-01

    Building upon the micromachined column idea proposed by the group of Regnier in 1998, we report on the first high-resolution reversed-phase separations in micromachined pillar array columns under pressure-driven LC conditions. A three component mixture could be separated in 3 s using arrays of

  6. Determination of D- and L-Amino Acids in Biological Samples by Two Dimensional Column Liquid Chromatography.

    NARCIS (Netherlands)

    van de Merbel, N.C.; Lingeman, H.; Brinkman, U.A.T.; Stenberg, M.; Oste, R.; Marko-Varga, G.; Gorton, L.

    1995-01-01

    A two-dimensional, column liquid chromatographic system is used for the determination of the D- and L-enantiomers of amino acids in biological samples. Separation of the amino acids is first on ion-exchange column by gradient elution with a sodium citrate-sodium chloride buffer. Enantioseparation is

  7. The three-dimensional model for helical columns on type-J synchronous counter-current chromatography.

    Science.gov (United States)

    Guan, Y H; van den Heuvel, Remco

    2011-08-05

    Unlike the existing 2-D pseudo-ring model for helical columns undergoing synchronous type-J planetary motion of counter-current chromatograph (CCC), the 3-D "helix" model developed in this work shows that there is a second normal force (i.e. the binormal force) applied virtually in the axial direction of the helical column. This force alternates in the two opposite directions and intensifies phase mixing with increasing the helix angle. On the contrary, the 2-D spiral column operated on the same CCC device lacks this third-dimensional mixing force. The (principal) normal force quantified by this "helix" model has been the same as that by the pseudo-ring model. With β>0.25, this normal centrifugal force has been one-directional and fluctuates cyclically. Different to the spiral column, this "helix" model shows that the centrifugal force (i.e. the hydrostatic force) does not contribute to stationary phase retention in the helical column. Between the popular helical columns and the emerging spiral columns for type-J synchronous CCC, this work has thus illustrated that the former is associated with better phase mixing yet poor retention for the stationary phase whereas the latter has potential for better retention for the stationary phase yet poor phase mixing. The methodology developed in this work may be regarded as a new platform for designing optimised CCC columns for analytical and engineering applications. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Rapid trace level determination of sulfonamide residues in honey with online extraction using short C-18 column by high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Sajid, Muhammad; Na, Na; Safdar, Muhammad; Lu, Xin; Ma, Lin; He, Lan; Ouyang, Jin

    2013-11-01

    A sensitive and inexpensive quantification method with online extraction using a short C-18 column for sulfonamide residues in honey by high performance liquid chromatography with fluorescence detector was developed and validated. In sample preparation, acid hydrolysis was used to break the N-glycoside bond between the honey sugar and sulfonamide drugs and derivatization of sulfonamide residues with fluorescamine was conducted at pH 3.5 using a citrate buffer (0.5M) in the honey matrix. The chromatography was carried out on Zorbax Extended C-18 (250mm×4.6mm; 5μm) column, using a mixture of acetonitrile and an acetate buffer (pH 4.50, 20mM) as a mobile phase. A Zorbax Extended C-18 (12mm×4.6mm; 5μm) column was used for online extraction of fifteen sulfonamide residues from honey sample with the help of a two position valve. The limit of quantification of sulfonamide residues in honey was less than 3ngg(-1), and the percentage recovery of study compounds in spiked honey sample was from 80% for sulfacetamide to 100% of sulfachloropyridazine. The developed method has excellent linearity for all studied sulfonamides with a correlation coefficient 0.993. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Development of molecular imprinted column-on line-two dimensional liquid chromatography for selective determination of clenbuterol residues in biological samples.

    Science.gov (United States)

    Guo, Pengqi; Luo, Zhimin; Xu, Xinya; Zhou, Yulan; Zhang, Bilin; Chang, Ruimiao; Du, Wei; Chang, Chun; Fu, Qiang

    2017-02-15

    A novel method coupling molecular imprinted monolithic column with two-dimensional liquid chromatography was developed and validated for the analysis of clenbuterol in pork liver and swine urine samples. The polymers were characterized by using Fourier transform infrared spectroscopy, nitrogen adsorption desorption analyses, frontal analysis and the adsorption of selectivity. The results indicated that the imprinted columns were well prepared and possessed high selectivity adsorption capacity. Subsequently, the MIMC-2D-LC (molecular imprinted monolithic column-two dimensional liquid chromatography) method was developed for the selective analysis of clenbuterol in practical samples. The accuracy ranged from 94.3% to 99.7% and from 93.7% to 99.6% for liver and urine, respectively. The relative standard deviation (RSD) of repeatability was lower than 8.6% for both analyses. The limit of detections was 16ng·mL(-1) for liver and 25ng·mL(-1) for urine, respectively. Compared with the reported methods, the disturbance of endogenous impurity could be avoided by the 2D-LC method. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Comprehensive on-line two-dimensional liquid chromatography × supercritical fluid chromatography with trapping column-assisted modulation for depolymerised lignin analysis.

    Science.gov (United States)

    Sun, Mingzhe; Sandahl, Margareta; Turner, Charlotta

    2018-03-16

    Lignin depolymerisation produces a large variety of low molecular weight phenolic compounds that can be upgraded to value-added chemicals. Detailed analysis of these complex depolymerisation mixtures is, however, hampered by the lack of resolving power of traditional analysis techniques. In this study, a novel online comprehensive two-dimensional reversed-phase liquid chromatography (RPLC) × supercritical fluid chromatography (SFC) method with trapping column interface was developed for the separation of phenolic compounds in depolymerised lignin samples. The trapping capacities of different trapping columns were evaluated. The influence of large volume water-containing injection on SFC performance was studied. The relation between peak capacity and first dimension flow rate and gradient was investigated. The optimized method was applied for the analysis of a depolymerised lignin sample. The RPLC × SFC system exhibited high degree of orthogonality. Compared with traditional loop based interface, trapping column interface can significantly shorten the analysis time and offer higher detectability, with the disadvantage of more severe undersampling in the first dimension. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Polystyrene-co-Divinylbenzene PolyHIPE Monoliths in 1.0 mm Column Formats for Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Sidratul Choudhury

    2016-03-01

    Full Text Available The reversed phase liquid chromatographic (RP-HPLC separation of small molecules using a polystyrene-co-divinylbenzene (PS-co-DVB polyHIPE stationary phases housed within 1.0 mm i.d. silcosteel columns is presented within this study. A 90% PS-co-DVB polyHIPE was covalently attached to the walls of the column housing by prior wall modification with 3-(trimethoxysilyl propyl methacrylate and could withstand operating backpressures in excess of 200 bar at a flow rate of 1.2 mL/min. Permeability studies revealed that the monolith swelled slightly in 100% acetonitrile relative to 100% water but could nevertheless be used to separate five alkylbenzenes using a flow rate of 40 µL/min (linear velocity: 0.57 mm/s. Remarkable column-to-column reproducibility is shown with retention factor variation between 2.6% and 6.1% for two separately prepared columns.

  12. On-line solid-phase extraction-short-column liquid chromatography combined with various tandem mass spectrometric scanning strategies for the rapid study of transformation of pesticides in surface water.

    NARCIS (Netherlands)

    Hogenboom, A.C.; Niessen, W.M.A.; Brinkman, U.A.T.

    1999-01-01

    The applicability of solid-phase extraction-short-column liquid chromatography using two short columns (i.e., 10 and 20 mm long) coupled on-line with tandem mass spectrometric detection is demonstrated for the rapid degradation study of pesticides and their transformation products in water at the

  13. Conventional and enantioselective gas chromatography with microfabricated planar columns for analysis of real-world samples of plant volatile fraction.

    Science.gov (United States)

    Cagliero, C; Galli, S; Galli, M; Elmi, I; Belluce, M; Zampolli, S; Sgorbini, B; Rubiolo, P; Bicchi, C

    2016-01-15

    Within a project exploring the application of lab-on-chip GC to in-field analysis of the plant volatile fraction, this study evaluated the performance of a set of planar columns (also known as microchannels, MEMS columns, or microfabricated columns) of different dimensions installed in a conventional GC unit. Circular double-spiral-shaped-channel planar columns with different square/rectangular sections up to 2m long were applied to the analysis of both essential oils and headspace samples of a group of medicinal and aromatic plants (chamomile, peppermint, sage, rosemary, lavender and bergamot) and of standard mixtures of related compounds; the results were compared to those obtained with reference narrow-bore columns (l:5m, dc:0.1mm, df:0.1 μm). The above essential oils and headspaces were first analyzed quali-and quantitatively with planar columns statically coated with conventional stationary phases (5%-phenyl-polymethylsiloxane and auto-bondable nitroterephthalic-acid-modified polyethylene glycol), and then submitted to chiral recognition of their diagnostic markers, by enantioselective GC with a planar columns coated with a cyclodextrin derivative (30% 6(I-VII)-O-TBDMS-3(I-VII)-O-ethyl-2(I-VII)-O-ethyl-β-cyclodextrin in PS-086). Column characteristics and analysis conditions were first optimized to obtain suitable retention and efficiency for the samples investigated. The planar columns tested showed performances close to the reference conventional narrow-bore columns, with theoretical plate numbers per meter (N/m) ranging from 6100 to 7200 for those coated with the conventional stationary phases, and above 5600 for those with the chiral selector. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Chromatographic column evaluation for the untargeted profiling of glucosinolates in cauliflower by means of ultra-high performance liquid chromatography coupled to high resolution mass spectrometry.

    Science.gov (United States)

    Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Montone, Carmela Maria; Piovesana, Susy; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2018-03-01

    The untargeted profiling is a promising approach for the characterization of secondary metabolites in biological matrices. Thanks to the recent rapid development of high-resolution mass spectrometry (HRMS) instrumentations, the number of applications by untargeted approaches for biological samples profiling has widely increased in the recent years. Despite the high potentialities of HRMS, however, a major issue in natural products analysis often arises in the upstream process of compounds separation. A separation technique is necessary to avoid phenomena such as signal suppression, and it is especially needed in the presence of isomeric metabolites, which are otherwise indistinguishable. Glucosinolates (GLSs), a group of secondary metabolites widely distributed among plants, resulted to be associated to the prevention of some serious diseases, such as cancer. This led to the development of several methods for the analysis of GLSs in vegetables tissues. The issue of GLSs chromatographic separation has been widely studied in the past because of the difficulty in the analysis of this highly polar and variable class of compounds. Several alternatives to reversed phase (RP) chromatography, sometimes not compatible with the coupling of liquid chromatography with mass spectrometry, have been tested for the analysis of intact GLSs. However, the availability of new stationary phases, in the last years, could allow the re-evaluation of RP chromatography for the analysis of intact GLSs. In this work, a thorough evaluation of four RP chromatographic columns for the analysis of GLSs in cauliflower (Brassica oleracea L. var. botrytis) extracts by an ultra-high performance liquid chromatographic system coupled via electrospray source to a hybrid quadrupole-Orbitrap mass spectrometer is presented. The columns tested were the following: one column Luna Omega polar C 18 , one column Kinetex Biphenyl, one column Kinetex core-shell XB-C 18 , two columns Kinetex core-shell XB-C 18

  15. Performance of different C18 columns in reversed-phase liquid chromatography with hydro-organic and micellar-organic mobile phases.

    Science.gov (United States)

    Ruiz-Angel, M J; Pous-Torres, S; Carda-Broch, S; García-Alvarez-Coque, M C

    2014-05-30

    Column selection in reversed-phase liquid chromatography (RPLC) can become a challenge if the target compounds interact with the silica-based packing. One of such interactions is the attraction of cationic solutes to the free silanols in silica-based columns, which is a slow sorption-desorption interaction process that gives rise to tailed and broad peaks. The effect of silanols is minimised by the addition of a competing agent in the mobile phase, such as the anionic surfactant sodium dodecyl sulphate (SDS). In micellar-organic RPLC, the adsorption of an approximately fixed amount of SDS monomers gives rise to a stable modified stationary phase, with properties remarkably different from those of the underlying bonded phase. The chromatographic behaviour (in terms of selectivity, analysis time and peak shape) of eight C18 columns in the analysis of weakly acidic phenols and basic β-blockers was examined with hydro-organic and micellar-organic mobile phases. The behaviour of the columns differed significantly when the cationic basic drugs were eluted with hydro-organic mobile phases. With micellar-organic mobile phases, the adsorption of surfactant, instead of making the columns similar, gave rise to a greater diversity of behaviours (especially in terms of selectivity and analysis time), for both groups of phenols and β-blockers, which should be explained by the residual effect of the underlying bonded stationary phase and the different amount of surfactant covering the packing. Therefore, the implementation of a micellar-organic procedure in RPLC will depend significantly on the selected type of C18 column. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Isolation and identification of arctiin and arctigenin in leaves of burdock (Arctium lappa L.) by polyamide column chromatography in combination with HPLC-ESI/MS.

    Science.gov (United States)

    Liu, Shiming; Chen, Kaoshan; Schliemann, Willibald; Strack, Dieter

    2005-01-01

    A simple method involving polyamide column chromatography in combination with HPLC-PAD and HPLC-ESI/MS for isolating and identifying two kinds of lignans, arctiin and arctigenin, in the leaves of burdock (Arctium lappa L.) has been established. After extraction of burdock leaves with 80% methanol, the aqueous phase of crude extracts was partitioned between water and chloroform and the aqueous phase was fractionated on a polyamide glass column. The fraction, eluting with 100% methanol, was concentrated and gave a white precipitate at 4 degrees C from which two main compounds were purified by semi-preparative HPLC. In comparison with the UV and ESI-MS spectra and the HPLC retention time of authentic standards, the compounds were determined to be arctiin and arctigenin. The extraction/separation technique was validated using an internal standard method.

  17. Chemometrics-assisted high performance liquid chromatography-diode array detection strategy to solve varying interfering patterns from different chromatographic columns and sample matrices for beverage analysis.

    Science.gov (United States)

    Yin, Xiao-Li; Wu, Hai-Long; Gu, Hui-Wen; Hu, Yong; Wang, Li; Xia, Hui; Xiang, Shou-Xia; Yu, Ru-Qin

    2016-02-26

    This work reports a chemometrics-assisted high performance liquid chromatography-diode array detection (HPLC-DAD) strategy to solve varying interfering patterns from different chromatographic columns and sample matrices for the rapid simultaneous determination of six synthetic colorants in five kinds of beverages with little sample pretreatment. The investigation was performed using two types of LC columns under the same elution conditions. Although analytes using different columns have different co-elution patterns that appear more seriously in complex backgrounds, all colorants were properly resolved by alternating trilinear decomposition (ATLD) method and accurate chromatographic elution profiles, spectral profiles as well as relative concentrations were obtained. The results were confirmed by those obtained from traditional HPLC-UV method at a particular wavelength and the results of both methods were consistent with each other. All results demonstrated that the proposed chemometrics-assisted HPLC-DAD method is accurate, economical and universal, and can be promisingly applied to solve varying interfering patterns from different chromatographic columns and sample matrices for the analysis of complex food samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Efficient on-column conversion of IgG1 trisulfide linkages to native disulfides in tandem with Protein A affinity chromatography.

    Science.gov (United States)

    Aono, Hiromasa; Wen, Dingy; Zang, Li; Houde, Damian; Pepinsky, R Blake; Evans, David R H

    2010-08-06

    Protein trisulfide linkages are generated by the post-translational insertion of a sulfur atom into a disulfide bond. Molecular heterogeneity was detected in a recombinant IgG(1) monoclonal antibody (mAb) and attributed to the presence of a protein trisulfide moiety. The predominant site of trisulfide modification was the bond between the heavy and light chains. The trisulfide was eliminated during purification of the IgG(1) mAb via a cysteine wash step incorporated into Protein A affinity column chromatography. Analysis of the cysteine-treated mAb by electrophoresis and peptide mapping indicated that the trisulfide linkages were efficiently converted to intact disulfide bonds (13% trisulfide decreased consistently to 1% or less) without disulfide scrambling or an increase in free sulfhydryls. The on-column trisulfide conversion caused no change in protein folding detectable by hydrogen/deuterium exchange or differential scanning calorimetry. Consistent with this, binding of the mAb to its antigen in vitro was insensitive to the presence of the trisulfide modification and to its removal by the on-column cysteine treatment. Similar, high efficiency trisulfide conversion was achieved for a second IgG(1) mAb using the column wash strategy (at least 7% trisulfide decreased to 1% or less). Therefore, trisulfide/disulfide heterogeneity can be eliminated from IgG(1) molecules via a convenient and inexpensive procedure compatible with routine Protein A affinity capture. Copyright 2010 Elsevier B.V. All rights reserved.

  19. Development and characterization of the α3β4α5 nicotinic receptor cellular membrane affinity chromatography column and its application for on line screening of plant extracts

    OpenAIRE

    Ciesla, L.; Okine, M.; Rosenberg, A.; Dossou, K.S.S.; Toll, L.; Wainer, I.W.; Moaddel, R.

    2015-01-01

    The α3β4α5 nAChR has been recently shown to be a useful target for smoking cessation pharmacotherapies. Herein, we report on the development and characterization of the α3β4α5 nicotinic receptor column by frontal displacement chromatography. The binding affinity of the nicotine and minor alkaloids found in tobacco smoke condensates were determined for both the α3β4 and α3β4α5 nicotinic receptors. It was demonstrated that while no subtype selectivity was observed for nicot...

  20. Polymethacrylate Monolithic and Hybrid Particle-Monolithic Columns for Reversed-Phase and Hydrophilic Interaction Capillary Liquid Chromatography

    Czech Academy of Sciences Publication Activity Database

    Jandera, P.; Urban, J.; Škeříková, V.; Langmeier, P.; Kubíčková, R.; Planeta, Josef

    2010-01-01

    Roč. 1217, č. 1 (2010), s. 22-33 ISSN 0021-9673 R&D Projects: GA ČR GA203/08/1536 Institutional research plan: CEZ:AV0Z40310501 Keywords : particle-monolithic columns * hybrid columns * polymethacrylate monoliths * capillary HPLC * HILIC * proteins * phenolic acids Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.194, year: 2010

  1. Considerations for the use of ultra-high pressures in liquid chromatography for 2.1mm inner diameter columns.

    Science.gov (United States)

    Broeckhoven, K; Desmet, G

    2017-11-10

    The current contribution investigates the effects of viscous heat dissipation in chromatographic columns (with an emphasis on so-called narrow bore columns with an inner diameter of 2.1mm) using numerical simulations of the temperature and velocity profiles and the resulting band broadening, for the first time at operating pressures up to 2000bar. When operating columns under well-thermostatted conditions to maintain a constant temperature of the mobile phase, a dramatic increase in plate heights can be observed that voids any advantage one could expect from the possibility to use smaller particles offered by the increased pressure limit. It is also clearly demonstrated that, even when the column is not temperature controlled, the backflow of heat along the wall can causes a significant loss in performance under standard operating conditions in a still air oven. It is found that for operating pressure above 1250bar, a significant (relative to the typical column performance) contribution to the observed plate height will be caused by viscous heating effects, which increases with increasing temperature dependency of the retention factor. In addition, unprecedented experimental measurements of the temperature effects at an operating pressure up to 2600bar were performed on a 10cm long, 2.1mm ID column showing a dramatic temperature increase up to 60°C relative to the inlet temperature when using methanol as a mobile phase. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Analysis of packing microstructure and wall effects in a narrow-bore ultrahigh pressure liquid chromatography column using focused ion-beam scanning electron microscopy.

    Science.gov (United States)

    Reising, Arved E; Schlabach, Sabine; Baranau, Vasili; Stoeckel, Daniela; Tallarek, Ulrich

    2017-09-01

    Column wall effects are well recognized as major limiting factor in achieving high separation efficiency in HPLC. This is especially important for modern analytical columns packed with small particles, where wall effects dominate the band broadening. Detailed knowledge about the packing microstructure of packed analytical columns has so far not been acquired. Here, we present the first three-dimensional reconstruction protocol for these columns utilizing focused ion-beam scanning electron microscopy (FIB-SEM) on a commercial 2.1mm inner diameter×50mm length narrow-bore analytical column packed with 1.7μm bridged-ethyl hybrid silica particles. Two sections from the packed bed are chosen for reconstruction by FIB-SEM: one from the bulk packing region of the column and one from its critical wall region. This allows quantification of structural differences between the wall region and the center of the bed due to effects induced by the hard, confining column wall. Consequences of these effects on local flow velocity in the column are analyzed with flow simulations utilizing the lattice-Boltzmann method. The reconstructions of the bed structures reveal significant structural differences in the wall region (extending radially over approximately 62 particle diameters) compared to the center of the column. It includes the local reduction of the external porosity by up to 10% and an increase of the mean particle diameter by up to 3%, resulting in a decrease of the local flow velocity by up to 23%. In addition, four (more ordered) layers of particles in the direct vicinity of the column wall induce local velocity fluctuations by up to a factor of three regarding the involved velocity amplitudes. These observations highlight the impact of radial variations in packing microstructure on band migration and column performance. This knowledge on morphological peculiarities of column wall effects helps guiding us towards further optimization of the packing process for analytical

  3. Mesoporous polybutadiene-modified zirconia for high-temperature packed capillary liquid chromatography: column preparation and temperature programming stability.

    Science.gov (United States)

    Andersen, Thomas; Nguyen, Quynh-Nhu T; Trones, Roger; Greibrokk, Tyge

    2003-11-07

    In the present study, three different methods for packing of 3 microm PBD-ZrO2 particles in 0.5 mm i.d. glass-lined stainless steel columns have been examined. The two first methods were based on a traditional downstream high-pressure technique using tetrachloromethane (Method I) or aqueous Triton X-100 (Method II) as slurry solvents, while Method III was an upstream high-pressure flocculating method with stirring, using isopropanol both as the slurry and packing solvent. Method I was found to be superior in terms of efficiency, producing 0.5 mm i.d. x 10 cm columns with almost 90,000 plates m(-1) for toluene (R.S.D. = 8.7%, n = 3), using a slurry concentration of 600 mg ml(-1), ACN-water (50:50 (v/v)) as the packing solvent and a packing pressure of 650 bars. For Method I, the slurry concentration, column i.d., column length and initial packing pressure were found to have a significant effect on column efficiency. Finally, the long-term temperature stability of the prepared columns was investigated. In isothermal mode, using ACN-20 mM phosphate buffer, pH 7 (50:50 (v/v)) as the mobile phase, the columns were found to be stable for at least 3,000 void volumes at 100 degrees C. At this temperature, the solute efficiencies changed about 5-18% and the retention factors changed about 6-8%. In temperature programming mode (not exceeding 100 degrees C), on the other hand, a rapid decrease in both column efficiency and retention factors was observed. However, when the columns were packed as initially described, ramped up and down from 50 to 100 degrees C for 48 h and refilled, fairly stable columns with acceptable efficiencies were obtained. Although not fully regaining their initial efficiency after refilling, the solute efficiencies changed about 19-28% (32-37%) and the retention factors changed about 4-5% (13-17%) after running 3,000 (25,000) void volumes or 500 (3,900) temperature programs.

  4. The separation of flavonoids from Pongamia pinnata using combination columns in high-speed counter-current chromatography with a three-phase solvent system.

    Science.gov (United States)

    Yin, Hao; Zhang, Si; Long, Lijuan; Yin, Hang; Tian, Xinpeng; Luo, Xiongming; Nan, Haihan; He, Sha

    2013-11-08

    The mangrove plant Pongamia pinnata (Leguminosae) is well known as a plant pesticide. Previous studies have indicated that the flavonoids are responsible of the biological activities of the plant. A new high-speed counter-current chromatography (HSCCC) method for the separation of three flavonoids, karanjin (1), pinnatin (2), and pongaflavone (3), from P. pinnata was developed in the present study. The lower and intermediate phase (LP and IP) of a new three-phase solvent system, n-hexane-acetonitrile-dichloromethane-water, at a volume ratio of 5:5:1:5, were used as the stationary phases, while the upper phase (UP) was used as the mobile phase, and the volume ratio between the stationary phases in the CCC column could be tuned by varying the initial pumped volume ratio of the stationary phases. The CCC columns containing all three phases of the solvent system were considered combination columns. According to the theories of combination column, it is possible to optimize the retention time of the target compounds by varying the volume ratio of the stationary phases in the HSCCC combination columns, as well as the suitable volume ratios of the stationary phases for the separation of the target compounds were predicted from the partition coefficients of the compounds in the three-phase solvent system. Then, three HSCCC separations using the combination columns with initial pumped LP:IP volume ratios of 1:0, 0.9:0.1, and 0.7:0.3 were performed separately based on the prediction. Three target compounds were prepared with high purity when the initial pumped volume ratio of the stationary phases was 0.9:0.1. The baseline separation of compounds 2 and 3 was achieved on the combination column with an initial pumped volume ratio of 0.7:0.3. Furthermore, the three experiments clearly demonstrated that the retentions and resolutions of the target compounds increased with an increasing volume ratio of IP, which is consistent with the prediction for the retention times for the

  5. Continuous bind-and-elute protein A capture chromatography: Optimization under process scale column constraints and comparison to batch operation.

    Science.gov (United States)

    Kaltenbrunner, Oliver; Diaz, Luis; Hu, Xiaochun; Shearer, Michael

    2016-07-08

    Recently, continuous downstream processing has become a topic of discussion and analysis at conferences while no industrial applications of continuous downstream processing for biopharmaceutical manufacturing have been reported. There is significant potential to increase the productivity of a Protein A capture step by converting the operation to simulated moving bed (SMB) mode. In this mode, shorter columns are operated at higher process flow and corresponding short residence times. The ability to significantly shorten the product residence time during loading without appreciable capacity loss can dramatically increase productivity of the capture step and consequently reduce the amount of Protein A resin required in the process. Previous studies have not considered the physical limitations of how short columns can be packed and the flow rate limitations due to pressure drop of stacked columns. In this study, we are evaluating the process behavior of a continuous Protein A capture column cycling operation under the known pressure drop constraints of a compressible media. The results are compared to the same resin operated under traditional batch operating conditions. We analyze the optimum system design point for a range of feed concentrations, bed heights, and load residence times and determine achievable productivity for any feed concentration and any column bed height. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:938-948, 2016. © 2016 American Institute of Chemical Engineers.

  6. Evaluation of size exclusion chromatography columns packed with sub-3μm particles for the analysis of biopharmaceutical proteins.

    Science.gov (United States)

    Goyon, Alexandre; Beck, Alain; Colas, Olivier; Sandra, Koen; Guillarme, Davy; Fekete, Szabolcs

    2017-05-19

    The aim of this study was to evaluate the practical possibilities and limitations of several recently introduced size exclusion chromatographic (SEC) columns of 150×4.6mm, sub-3μm (Agilent AdvanceBioSEC 2.7μm, Tosoh TSKgel UP-SW3000 2.0μm, Phenomenex Yarra SEC X-150 1.8μm and Waters Acquity BEH200 1.7μm) for the separation of biopharmaceutical proteins. For this purpose, some model proteins were tested, as well as several commercial therapeutic monoclonal antibodies (mAbs) and antibody-drug-conjugates (ADCs). Calibration curves were drawn to highlight the applicability of these new SEC columns for the separation of mAbs, ADCs and their aggregates, despite some differences in their nominal pore diameter (vary from 150 to 300Å). The kinetic performance (van Deemter curves and kinetic pots) was evaluated. Columns packed with 1.7-2.0μm particles improved the plate count by a factor of 1.5-2 compared to 2.7μm particles, which is in agreement with theoretical expectations. Finally, possible secondary hydrophobic and/or electrostatic interactions between the SEC stationary phases and biopharmaceutical proteins were systematically studied. Significant differences in nonspecific interactions were observed, with hydrophobic interactions generally exerting more influence than electrostatic interactions. The use of a novel bond chemistry with the AdvanceBioSEC column was found highly effective to limit non-specific interactions and pave the way to further improvements for column provider. At the end, the average resolutions achieved on the four sub-3μm SEC columns between monomer and dimer structures were comparable for ten approved mAbs products. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Application of a simple column-switching ion chromatography technique for removal of matrix interferences and sensitive fluorescence determination of acidic compounds (pharmaceutical drugs) in complex samples.

    Science.gov (United States)

    Muhammad, Nadeem; Subhani, Qamar; Wang, Fenglian; Guo, Dandan; Zhao, Qiming; Wu, Shuchao; Zhu, Yan

    2017-09-15

    This work illustrates the introduction of a simple, rugged and flexible column-switching ion chromatography (IC) technique for an automated on-line QuEChERS extracted samples extracts washing followed by sensitive fluorescence (FLD) determination of five acidic pharmaceutical drugs namely; clofibric acid (CLO), ibuprofen (IBU), aspirin (ASP), naproxen (NAP) and flurobrofen (FLU) in three complex samples (spinach, apple and hospital sewage sludge). An old anion exchange column IonPac ® AS11-HC was utilized as a pre-treatment column for on-line washing of inorganic and organic interferences followed by isocratic separation of five acidic drugs with another anion exchange IonPac ® AS12A analytical column by exploiting the column-switching technique. This novel method exhibited good linearity with correlation coefficients (r 2 ) for all drugs were in the range 0.976-0.996. The limit of detection and quantification of all five acidic drugs were in the range 0.024μg/kg to 8.70μg/kg and 0.082μg/kg to 0.029mg/kg, respectively, and better recoveries in the range 81.17-112.5% with percentage relative standard deviations (RSDs) less than 17.8% were obtained. This on-line sample pre-treatment method showed minimum matrix effect in the range of 0.87-1.25 except for aspirin. This simple rugged and flexible column-switching system required only 28min for maximum elimination of matrices and interferences in three complex samples extracts, isocratic separation of five acidic drugs and for the continuous regeneration of pre-treatment column prior to every subsequent analysis. Finally, this simple automated IC system was appeared so rugged and flexible, which can eliminate and wash out most of interference, impurities and matrices in complex samples, simply by adjusting the NaOH and acetonitrile concentration in washing mobile phase with maximum recoveries of acidic analytes of interest. Copyright © 2017. Published by Elsevier B.V.

  8. [Simultaneous determination of zeranols and chloramphenicol in foodstuffs of animal origin by combination immunoaffinity column clean-up and liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Wang, Qing; Wang, Guomin; Xi, Cunxian; Li, Xianliang; Chen, Dongdong; Tang, Bobin; Zhang, Lei; Zhao, Hua

    2014-06-01

    A combination immunoaffinity column (IAC-CZ) clean-up and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical method was successfully developed for zearalenol, beta-zearalenol and zearalenone) and chloramphenicol (CAP) in foodstuffs of animal origin. The samples (fish, liver, milk and honey) were enzymatically digested by beta-glucuronidase/sulfatase for about 16 h and then extracted with ether. The extracts were evaporated to dryness and then the residues were dissolved by 1.0 mL of 50% acetonitrile solution. After filtered and diluted with PBS buffer, the reconstituted solution were cleaned-up with a IAC-CZ and then analyzed by LC-MS/MS in multiple reaction monitoring (MRM) mode. The chromatographic separation was performed on a Shimadzu Shim-pack VP-ODS column with gradient elution by acetonitrile and 2 mmol/L ammonium acetate solution. The detection was carried out by electrospray negative ionization mass spectrometry in MRM mode. The proposed method was validated by the limit of detection (0.04-0.10 microg/kg), linearity (R2 > or = 0.999 0), average recoveries (70.9%-95.6%) and precisions (2.0% - 11.8%). The developed method is reliable, sensitive and has good applicability. The combination immunoaffinity column was proved to be an effective pretreatment technique to decrease the matrix effect, and it met the requirements of residue analysis of co-occurring zeranols and chloramphenicol.

  9. Silica-based monolithic capillary columns modified by liposomes for characterization of analyte–liposome interactions by capillary liquid chromatography

    Czech Academy of Sciences Publication Activity Database

    Moravcová, Dana; Planeta, Josef; Wiedmer, S. K.

    2013-01-01

    Roč. 1317, SI (2013), s. 159-166 ISSN 0021-9673 R&D Projects: GA MV VG20112015021; GA ČR(CZ) GAP206/11/0138 Institutional support: RVO:68081715 Keywords : monolithic silica capillary column * immobilized liposomes * biomimicking stationary phase Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.258, year: 2013

  10. Characterization of polymer-based monolithic capillary columns by inverse size-exclusion chromatography and mercury-intrusion porosimetry

    NARCIS (Netherlands)

    Urban, J.; Eeltink, S.; Jandera, P.; Schoenmakers, P.J.

    2008-01-01

    Organic-polymer monolithic capillary columns were prepared in fused-silica capillaries by a radical copolymerization reaction of butyl methacrylate and ethylene dimethacrylate monomers in the presence of 1,4-butanediol and 1-propanol as porogen solvents and azobisisobutyronitrile as the initiator.

  11. Portable automated separation system for routine purification and/or pre-concentration of radionuclides based on column chromatography

    International Nuclear Information System (INIS)

    Zoriy, M.V.; Flucht, R.; Burow, M.

    2013-01-01

    In recent years the purification and/or pre-concentration of radionuclides before the measurement has grown increasing interest in analytical chemistry. In this study, a new compact and portable stand-alone equipment permitting automatisation of various separation tasks is developed. The new system allows performing quick and reliable automated separation of the selected radionuclide. Since there is no need for permanent manual control of the separation procedures (automatic loading of the sample, washing and stripping solution on the column are controlled via a computer program) the system can be operated overnight. The new system posses the possibility of more variable control for the separation process via new developed user-friendly software, is shielded against the chemical vapors and could be universally equipped with any available chromatographic column. For the automated separation of U, Pu and Am isotopes (achieved recoveries were in the range of 65-95 %, depending on the element separated. The data, presented, show that the application of the module should be also straightforward for other elements: simply by changing the chromatographic columns with the resin having high chemical selectivity for the target ion. The developed separation column module, software and hardware can be readily adapted in any laboratory to meet defined analytical requirements. (author)

  12. Analysis of oil-biodiesel samples by high performance liquid chromatography using the normal phase column of new generation and the evaporative light scattering detector.

    Science.gov (United States)

    Fedosov, Sergey N; Fernandes, Natalia A; Firdaus, Mohd Y

    2014-01-24

    Conversion of vegetable oil to biodiesel is usually monitored by gas chromatography. This is not always convenient because of (i) an elaborate derivatization of the samples; (ii) inhibition of this process by methanol and water; (iii) low stability of the derivatives under storage. HPLC methods are apparently more convenient, but none of the described variants had won a wide recognition so far. This can be ascribed to the problems of reproducibility (in the case of normal phase chromatography) and limited separation of some analytes (in the case of reverse phase chromatography). Here we report an HPLC procedure suitable for separation of biodiesel, free fatty acids, glycerides, glycerol and lecithin. The normal phase column of new generation (Poroshell 120 HILIC) and the novel gradient were used. The method was tested on both the artificial mixtures and the crude reaction samples. Elution of the analytes was monitored by an evaporative light scattering detector. This method is usually confined to a very limited range of masses, where only a part of the complex calibration curve is used. We have analyzed the light scattering signal within a very broad range of masses, whereupon the calibration curves were produced. The data were approximated by the appropriate equations used afterward to recalculate the signal to the mass in a convenient way. An experimental conversion of rapeseed oil to biodiesel was performed by a liquid lipase formulation. This process was monitored by HPLC to illustrate advantages of the suggested registration method. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Monolithic columns based on a poly(styrene-divinylbenzene-methacrylic acid) copolymer for capillary liquid chromatography of small organic molecules

    Czech Academy of Sciences Publication Activity Database

    Svobodová, A.; Křížek, T.; Širc, Jakub; Šálek, Petr; Tesařová, E.; Coufal, P.; Štulík, K.

    2011-01-01

    Roč. 1218, č. 11 (2011), s. 1544-1547 ISSN 0021-9673 R&D Projects: GA AV ČR KAN200520804 Institutional research plan: CEZ:AV0Z40500505 Keywords : capillary liquid chromatography * methacrylic acid * polystyrene-based monolithic stationary phase Subject RIV: EI - Biotechnology ; Bionics Impact factor: 4.531, year: 2011

  14. Programmed temperature vaporizing injector to filter off disturbing high boiling and involatile material for on-line high performance liquid chromatography gas chromatography with on-column transfer.

    Science.gov (United States)

    Biedermann, Maurus; Grob, Koni

    2013-03-15

    Insertion of a programmed temperature vaporizing (PTV) injector under conditions of concurrent solvent recondensation (CSR) into the on-line HPLC-GC interface for on-column transfer (such as the retention gap technique with partially concurrent eluent evaporation) enables filtering off high boiling or involatile sample constituents by a desorption temperature adjusted to the required cut-off. Details of this technique were investigated and optimized. Memory effects, observed when transferred liquid was sucked backwards between the transfer line and the wall of the injector liner, can be kept low by a small purge flow rate through the transfer line at the end of the transfer and the release of the liquid through a narrow bore capillary kept away from the liner wall. The column entrance should be within the well heated zone of the injector to prevent losses of solute material retained on the liner wall during the splitless period. The desorption temperature must be maintained until an elevated oven temperature is reached to prevent peak broadening resulting of a cool inlet section in the bottom part of the injector. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. High-resolution ultrahigh-pressure long column reversed-phase liquid chromatography for top-down proteomics

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Yufeng; Tolic, Nikola; Piehowski, Paul D.; Shukla, Anil K.; Kim, Sangtae; Zhao, Rui; Qu, Yi; Robinson, E. W.; Smith, Richard D.; Pasa-Tolic, Ljiljana

    2017-05-01

    We report development of an approach providing high-resolution RPLC of proteins and its utility for mass spectrometry-based top-down proteomics. A chromatographic peak capacity of ~450 was achieved for proteins and large polypeptides having MWs up to 43 kDa in the context of proteomics applications. RPLC column lengths from 20 to 200 cm, particle sizes from 1.5 to 5 m, bonding alkyl chains from C1 to C2, C4, C8, and C18, and particle surface structures that spanned porous, superficially porous (porous shell, core-shell), and nonporous were investigated at pressures up to14K psi. Column length was found as the most important factor for >20 kDa proteins in gradient RPLC, and shortening column length degraded RPLC resolution and sensitivity regardless of the size and surface structure of the packing particles used. The alkyl chains bonded to the silica particle surface significantly affected the RPLC recovery and efficiency, and short alkyl C1-C4 phases provided higher sensitivity and resolution than C8 and C18 phases. Long gradient separations (e.g., >10 hours) with long columns (e.g., 100 cm) were particularly effective in conjunction with use of high accuracy mass spectrometers (e.g., the Orbitrap Elite) for top-down proteomics with improved proteoform coverage by allowing multiple HCD, CID, and ETD dissociation modes. It was also found that HCD produced small fragments useful for proteoform identification, while low energy CID and ETD often complemented HCD by providing large fragments.

  16. Kinetic performance of reversed-phase C18 high-performance liquid chromatography columns compared by means of the Kinetic Plot Method in pharmaceutically relevant applications.

    Science.gov (United States)

    Fanigliulo, A; Cabooter, D; Bellazzi, G; Allieri, B; Rottigni, A; Desmet, G

    2011-05-27

    Four fully porous C18 columns (Hypersil Gold, ACE3, Xbridge and Gemini NX), widely employed in the pharmaceutical industry, were compared in terms of efficiency and analysis speed with the Kinetic Plot Method. Weakly basic, medium-sized, N-containing pharmaceutical compounds from GlaxoSmithKline Research and Development were used as test molecules. Isocratic elution was carried out at pH 4.5 and pH 8.0 with acetonitrile as organic modifier. The columns under evaluation included highly pure silica supports (Hypersil Gold, ACE3) and hybrid polymer-silica supports (XBridge, Gemini NX). Both types of columns claim for nearly absent secondary interactions with ionized silanol groups and are therefore applicable in a wide pH range. This is an important feature for method development purposes in pharmaceutical industries. The Kinetic Plot Method was used to compare the support characteristics and assess the kinetic performance of the columns in different experimental conditions. Although the evaluated columns have roughly identical particle diameters (from 3.0 to 3.5μm) according to their manufacturers, large differences in kinetic performance were observed at pH 4.5 that can be accounted for by different flow resistances, porosities and average particle diameters, experimentally determined from scanning electron microscopy and laser light scattering experiments on loose stationary phase material. The ACE3 column was the best performing support among the evaluated columns, due to its excellent efficiency and average flow resistance. The better performance of the ACE3 column was due to its better packing quality, as could be derived from its impedance plot. Kinetic plots of resolution of a critical pair versus analysis time and column length were established at pH 8.0. These plots can be used as a method development tool to tailor the separation conditions to the required resolution of a given critical pair, combining efficiency and selectivity features of the column

  17. A Quadrature Method of Moments for Polydisperse Flow in Bubble Columns Including Poly-Celerity, Breakup and Coalescence

    Directory of Open Access Journals (Sweden)

    Thomas Acher

    2014-12-01

    Full Text Available A simulation model for 3D polydisperse bubble column flows in an Eulerian/Eulerian framework is presented. A computationally efficient and numerically stable algorithm is created by making use of quadrature method of moments (QMOM functionalities, in conjunction with appropriate breakup and coalescence models. To account for size dependent bubble motion, the constituent moments of the bubble size distribution function are transported with individual velocities. Validation of the simulation results against experimental and numerical data of Hansen [1] show the capability of the present model to accurately predict complex gas-liquid flows.

  18. Evaluation and comparison of the kinetic performance of ultra-high performance liquid chromatography and high-performance liquid chromatography columns in hydrophilic interaction and reversed-phase liquid chromatography conditions.

    Science.gov (United States)

    Song, Huiying; Adams, Erwin; Desmet, Gert; Cabooter, Deirdre

    2014-11-21

    An intrinsic performance comparison is made of the reduction in analysis time that can be obtained when switching from HPLC to UHPLC column formats in HILIC and reversed-phase conditions. A detailed overview of the packing characteristics of both stationary phase types is given first. It is demonstrated that HILIC columns demonstrate higher external porosity values than their reversed-phase counterparts resulting in lower flow resistance values. Column total porosity values determined from the elution time of a small marker molecule are shown to depend strongly on the composition of the mobile phase. To omit errors that might arise from an over- or underestimation of the column void time, all plate height and kinetic plot data are therefore expressed as a function of the interstitial velocity. Although only a limited number of columns are evaluated in this study, it is shown that the column efficiency of the HILIC columns is lower than that of their reversed-phase counterparts, at least for the compounds evaluated here. Despite this lower efficiency, the kinetic performance of both stationary phase types is similar, due to the much lower viscosity of the mobile phases typically used in HILIC conditions. Finally, it is demonstrated that a similar, yet slightly larger reduction in analysis time can be obtained when switching from HPLC column formats to UHPLC formats in HILIC compared to reversed-phase conditions. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Gas chromatography for in situ analysis of a cometary nucleus V. Study of capillary columns' robustness submitted to long-term reduced environmental pressure conditions.

    Science.gov (United States)

    Szopa, C; Sternberg, R; Coscia, D; Goesmann, F; Gomes, R; Legrand, S; Jerome, M; Meierhenrich, U J; Raulin, F

    2014-11-14

    With the European Space Agency's Rosetta space mission to comet 67P/Churyumov-Gerasimenko, a gas chromatograph, part of the COmetary Sampling And Composition (COSAC) experiment, travelled for about 10 years in the interplanetary medium before operating at the surface of the cometary nucleus in November 2014. During its journey in space, the instrument was exposed to the constraining conditions of the interplanetary medium, including reduced environmental pressures. In order to estimate the potential influence of this severe condition on the chromatographic capillary columns, their stationary phase and the subsequent separation capability, a set of flight spare columns were kept under reduced environmental pressure in the laboratory for the same duration as the probe sent to the comet. The columns' analytical performances were evaluated recently and compared to the original ones obtained just before the launch of the Rosetta probe. The results presented here show that the chromatographic performances of the spare chromatographic columns were not altered in time. From this result, it can be expected that the flight instrument will perform nominally for the analysis of the first cometary nucleus sample to be collected ever, and that the preparation of the interpretation of the data to be taken at the cometary surface nucleus can be done through calibration of these spare columns, and other spare components of the instrument. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Validation of a method for simultaneous determination of menthol and methyl salicylate in pharmaceuticals by capillary gas chromatography with cool on-column injection.

    Science.gov (United States)

    Krzek, Jan; Czekaj, Janusz Sławomir; Rzeszutko, Włodzimierz

    2003-01-01

    The conditions for the identification and quantitative determination of menthol and methyl salicylate in ointment Balsamum Mentholi Compositum on a hydrocarbon-ester base (vaseline-lanolin), have been established by using capillary gas chromatography with cool on-column injection and flame ionization detection (FID). The good separation of menthol (tR = 7.2 min), methyl salicylate (tR = 8.7 min) and thymol (tR = 12.3 min) and camphor (tR = 6.0 min), used as alternative internal standards, beside vehiculum constituents (peak of tR = 15.8 min) was obtained. The method features a high sensitivity - detection limit for menthol and methyl salicylate was 0.1 ng and 5.0 ng, respectively, high accuracy, precision and recovery for active substances: 100.0% +/- 2.2%, when camphor was used as an internal standard.

  1. Determination of Formaldehyde in Frozen Fish with Formaldehyde Dehydrogenase Using a Flow Injection System with an Incorporated Gel-filtration Chromatography Column

    DEFF Research Database (Denmark)

    Bechmann, Iben Ellegaard

    1996-01-01

    A flow injection analysis (FIA) system for determination of formaldehyde in frozen fish products is described. The system provides a rapid and selective determination of formaldehyde in aqueous fish extracts by the combination of a deproteinization procedure and a stopped-flow enzymatic approach...... in a FIA system. The FIA system is furnished with a gel-filtration chromatography column for on-line removal of the proteins from the extract before the enzymatic analysis is performed. Compared with the standard methods for determination of formaldehyde in fish products the present method is much faster...... and less affected by interferences. The limit of detection for the proposed method is 2.5 mg/l of formaldehyde. The sampling frequency is about 10 determinations per hour....

  2. Determination of Wastewater Compounds in Sediment and Soil by Pressurized Solvent Extraction, Solid-Phase Extraction, and Capillary-Column Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Burkhardt, Mark R.; Zaugg, Steven D.; Smith, Steven G.; ReVello, Rhiannon C.

    2006-01-01

    A method for the determination of 61 compounds in environmental sediment and soil samples is described. The method was developed in response to increasing concern over the effects of endocrine-disrupting chemicals in wastewater and wastewater-impacted sediment on aquatic organisms. This method also may be used to evaluate the effects of combined sanitary and storm-sewer overflow on the water and sediment quality of urban streams. Method development focused on the determination of compounds that were chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Sediment and soil samples are extracted using a pressurized solvent extraction system. The compounds of interest are extracted from interfering matrix components by high-pressure water/isopropyl alcohol extraction. The compounds were isolated using disposable solid-phase extraction (SPE) cartridges containing chemically modified polystyrene-divinylbenzene resin. The cartridges were dried with nitrogen gas, and then sorbed compounds were eluted with methylene chloride (80 percent)-diethyl ether (20 percent) through Florisil/sodium sulfate SPE cartridge, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-sand samples fortified at 4 to 72 micrograms averaged 76 percent ?13 percent relative standard deviation for all method compounds. Initial method reporting levels for single-component compounds ranged from 50 to 500 micrograms per kilogram. The concentrations of 20 out of 61 compounds initially will be reported as estimated with the 'E' remark code for one of three reasons: (1) unacceptably low-biased recovery (less than 60 percent) or highly variable method performance

  3. Separation of aliphatic carboxylic acids and benzenecarboxylic acids by ion-exclusion chromatography with various cation-exchange resin columns and sulfuric acid as eluent.

    Science.gov (United States)

    Ohta, Kazutoku; Ohashi, Masayoshi; Jin, Ji-Ye; Takeuchi, Toyohide; Fujimoto, Chuzo; Choi, Seong-Ho; Ryoo, Jae-Jeong; Lee, Kwang-Pill

    2003-05-16

    The application of various hydrophilic cation-exchange resins for high-performance liquid chromatography (sulfonated silica gel: TSKgel SP-2SW, carboxylated silica gel: TSKgel CM-2SW, sulfonated polymethacrylate resin: TSKgel SP-5PW, carboxylated polymethacrylate resins: TSKgel CM-5PW and TSKgel OA-Pak A) as stationary phases in ion-exclusion chromatography for C1-C7 aliphatic carboxylic acids (formic, acetic, propionic, butyric, isovaleric, valeric, isocaproic, caproic, 2-methylhexanoic and heptanoic acids) and benzenecarboxylic acids (pyromellitic, trimellitic, hemimellitic, o-phthalic, m-phthalic, p-phthalic, benzoic, salicylic acids and phenol) was carried out using diluted sulfuric acid as the eluent. Silica-based cation-exchange resins (TSKgel SP-2SW and TSKgel CM-2SW) were very suitable for the ion-exclusion chromatographic separation of these benzenecarboxylic acids. Excellent simultaneous separation of these benzenecarboxylic acids was achieved on a TSKgel SP-2SW column (150 x 6 mm I.D.) in 17 min using a 2.5 mM sulfuric acid at pH 2.4 as the eluent. Polymethacrylate-based cation-exchange resins (TSKgel SP-5PW, TSKgel CM-5PW and TSKgel OA-Pak A) acted as advanced stationary phases for the ion-exclusion chromatographic separation of these C1-C7 aliphatic carboxylic acids. Excellent simultaneous separation of these C1-C7 acids was achieved on a TSKgel CM-5PW column (150 x 6 mm I.D.) in 32 min using a 0.05 mM sulfuric acid at pH 4.0 as the eluent.

  4. Measuring Ochratoxin A Concentrations in Coffee Beverages with Immunoaffinity Columns and Ultra-Performance Liquid Chromatography/Tandem Mass Spectrometry.

    Science.gov (United States)

    Chen, Wen-Ling; Chang, Chiung-Wen; Chen, Chia-Yang

    2016-01-01

    This study developed and validated a method for measuring concentrations of ochratoxin A (OTA) in coffee beverages, not coffee beans. The new method involved extraction using immunoaffinity columns and ultra-performance LC (UPLC)-MS/MS using isotope-dilution techniques. The combination of a fused-core column and UPLC significantly shortened chromatographic time to 3 min compared to reported UPLC methods. The method was sensitive, with an LOD and LOQ of 0.52 and 1.73 pg/mL, respectively. Quantitative intraday (n = 4) and interday (n = 4) biases and RSD were both below 15%. The OTA levels in 40 samples of freshly brewed coffee from chain stores, 24 samples of canned ready-to-drink coffee, and 6 beverages made from instant coffee granules ranged from 1.60 to 93.2 pg/mL (90% positive), 6.00 to 131 pg/mL (100% positive), and 21.8 to 59.0 pg/mL (100% positive), respectively. Based on published tolerable daily intake, men and women in Taiwan should consume no more than 6.3 and 5.1 fifteen gram packages of instant coffee per day, respectively. Specific suggestions were not made for brewed coffee and canned coffee because of their large variation in OTA concentrations. This study should be more relevant to actual human exposure than those studying OTA in green, roasted, and ground coffee beans alone.

  5. Express analysis of explosives, chemical warfare agents and drugs with multicapillary column gas chromatography and ion mobility increment spectrometry.

    Science.gov (United States)

    Buryakov, Igor A

    2004-02-05

    Description of a gas chromatograph designed for express analysis of explosives (2,4-dinitrotoluene, 2,4,6-trinitrotoluene, pentaerythritol tetranitrate), chemical warfare agents (mustard gas, lewisite, sarin) and drugs (heroin, cocaine hydrochloride, crack) is given. The devices comprises a multicapillary chromatographic column and an ion mobility increment spectrometer (MCC-IMIS). The main analytical characteristics of an IMIS (estimated detection limit (DL), linear dynamic range (LDR), speed of response) and a chromatographic column (separation power, degree of separation, a number of possible peaks at a chromatogram section, divided by analysis time) are determined. The maximum value of DL equal to 5 pg/ml was registered for cis-alpha-LW, and the lowest one of 0.001 pg/ml was for cocaine. The maximum value of LDR equal to 1000 was registered for sarin and the lowest one of 150 was for the ions of lewisite. Speed of response of one compound detection with the IMIS was 0.7 s.

  6. Highly sensitive and selective determination of 9, 10-phenanthrenequinone in airborne particulates using high-performance liquid chromatography with pre-column derivatization and fluorescence detection.

    Science.gov (United States)

    Kishikawa, Naoya; Wada, Mitsuhiro; Ohba, Yoshihito; Nakashima, Kenichiro; Kuroda, Naotaka

    2004-11-19

    9,10-Phenanthrenequinone (PQ), is one of the components of diesel exhaust particulates, has potent harmful effects on human health. For the determination of PQ in airborne particulates, a highly sensitive and selective high-performance liquid chromatography (HPLC) method was developed with fluorescence detection following the pre-column fluorescent derivatization. PQ was derivatized with benzaldehyde as a derivatizing reagent in the presence of ammonium acetate to give fluorescent 2-phenyl-1H-phenanthro [9,10-d] imidazole. The maximum fluorescence intensity of the derivative was observed by the reaction with 0.2M benzaldehyde and 0.5 M ammonium acetate at 100 degrees C for 30 min. The HPLC separation of fluorescent derivative of PQ was performed within 20 min on an ODS column with a mixture of acetonitrile-water (55:45, v/v) as a mobile phase. Highly sensitive and selective determination of PQ was attained with the detection limit of 5 fmol (S/N = 3). By the proposed method, PQ in airborne particulates was successfully determined in the range 0.26-0.30 ng/m3 (n = 3).

  7. Development of a high-performance liquid chromatography method based on a core-shell column approach for the rapid determination of multiclass polyphenols in grape pomaces.

    Science.gov (United States)

    Fontana, Ariel R; Antoniolli, Andrea; Bottini, Rubén

    2016-02-01

    A rapid and economically affordable reverse-phase chromatographic approach based on a core-shell column with high-performance liquid chromatography multi-wavelength detector (HPLC-MWD) is proposed for the quantification and quality control of multiclass polyphenols (PPs). The separation of 20 relevant polyphenols from grape pomace extracts (GPEs) was achieved in less than 12 min by using a Kinetex C18 column (3.0 mm × 100 mm, 2.6 μm) with a gradient system of ultrapure water (0.1% formic acid) and acetonitrile, a temperature of 35 °C and a flow rate of 0.8 mL min(-1). The maximum backpressure reached was 327 bar, meaning the developed method is adequate for standard HPLC instruments. The applicability of the method was demonstrated by the determination of PPs in GPEs of different red grape varieties. Cabernet Sauvignon GPE showed the highest content of studied PPs (9804.2 μg g(-1)GPE) followed by Bonarda GPE (7302.0 μg g(-1)GPE). Besides the methodological development for a high throughput routine quality control of GPEs, this is the first report of PPs content for Bonarda and Aspirant Bouchet GPE, so the results add knowledge for these grape varieties cultivated in Argentina. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. A sensitive and selective quantification of catecholamine neurotransmitters in rat microdialysates by pre-column dansyl chloride derivatization using liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Nirogi, Ramakrishna; Komarneni, Prashanth; Kandikere, Vishwottam; Boggavarapu, Rajeshkumar; Bhyrapuneni, Gopinadh; Benade, Vijay; Gorentla, Srinivasarao

    2013-01-15

    A rapid and sensitive liquid chromatography tandem mass spectrometry method for simultaneous quantification of catecholamine neurotransmitters in microdialysates was developed. The catecholamine neurotransmitters dopamine (DA) and norepinephrine (NE) were pre-column derivatized with dansyl chloride and analyzed. A gradient elution method was used to separate the analytes from the interferences on an Agilent Poroshell 120 EC-C18 outer porous micro particulate column. The method was robust and sensitive to determine with the lower limit of quantification value of 0.068pmol/mL and 0.059pmol/mL for DA and NE, respectively. It has acceptable precision and accuracy for concentrations over the standard curve range. The method was successfully applied for simultaneous quantitation of DA and NE in the prefrontal cortex (PFC) dialysates of rats obtained from a microdialysis study dosed with vehicle and atomoxetine through intra peritoneal (i.p.) route at a dose of 3mg/kg to monitor the change in extracellular concentrations. Thus, accomplishment of this method would facilitate the neurochemical monitoring for discovery of new chemical entities targeted for the treatment of attention deficit hyperactivity disorder (ADHD). Copyright © 2012. Published by Elsevier B.V.

  9. [Determination of pyrethroid pesticides in tea by series two-solid phase extraction-columns cleanup and gas chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Liu, Li; Zhang, Qi; Wang, Haiyan; Feng, Feng; Cao, Hairong; Yang, Zhen; Ke, Zhijun; Chen, Xiyao

    2017-08-08

    A rapid determination method of three pyrethroid pesticides (cyfluthrin, cypermethrin and fenvalerate) in tea was developed by series two-solid phase extraction-column cleanup and external standard method coupled with gas chromatography-tandem mass spectrometry (GC-MS/MS) in 30 min. The pesticide residues in tea were extracted with acetonitrile, and cleaned up by Carb/NH 2 and SLH solid-phase extraction columns. After filtration, the target compounds were analyzed by GC-MS and quantified by the external standard method. Under the optimized conditions, good linear ranges of 0.05-2.00 mg/kg were obtained. The limits of detection varied from 0.3 to 1.0 μ g/kg. The linear correlation coefficients were greater than 0.999. At three spiked levels (0.10, 0.50 and 2.00 mg/L), the average recoveries were determined between 80.6% and 116.3% in the four matrices. The inter-day relative standard deviations were between 1.3%-12.6%, and the intra-day relative standard deviations were between 2.7% and 12.1%. This method is simple, fast, and has a good reproducibility, which can meet the requirements of the rapid detection of pyrethroid pesticides in tea.

  10. [Determination of six main components in compound theophylline tablet by convolution curve method after prior separation by column partition chromatography

    Science.gov (United States)

    Zhang, S. Y.; Wang, G. F.; Wu, Y. T.; Baldwin, K. M. (Principal Investigator)

    1993-01-01

    On a partition chromatographic column in which the support is Kieselguhr and the stationary phase is sulfuric acid solution (2 mol/L), three components of compound theophylline tablet were simultaneously eluted by chloroform and three other components were simultaneously eluted by ammonia-saturated chloroform. The two mixtures were determined by computer-aided convolution curve method separately. The corresponding average recovery and relative standard deviation of the six components were as follows: 101.6, 1.46% for caffeine; 99.7, 0.10% for phenacetin; 100.9, 1.31% for phenobarbitone; 100.2, 0.81% for theophylline; 99.9, 0.81% for theobromine and 100.8, 0.48% for aminopyrine.

  11. Effects of pressure and frictional heating on protein separation using monolithic columns in reversed-phase chromatography.

    Science.gov (United States)

    Mann, Benjamin F; Makarov, Alexey A; Wang, Heather; Welch, Christopher J

    2017-03-17

    Pressure is not typically controlled or adjusted independently of flow rate during method development in reversed-phase LC (RPLC). However, it has been shown that pressure has an effect on analyte molecular molar volume, and the magnitude of this effect is greater for proteins and ionizable compounds than neutral small molecules. This phenomenon has received attention recently in the context of porous sub-2-micron particle packed columns. The present study surveys the effect of pressure and frictional heating on RPLC separations using commercially-available monolithic columns at constant flow rate and with controlled external temperature. Because the current monoliths cannot be operated at high pressures, all experiments were conducted with pressures at or below 200bar. Nonetheless, substantial changes in retention were still observed; for example, an increase in pressure of 75bar shifted the retention factor for bovine insulin from 1.27 to 1.78, a 40% increase, while a similar experiment with the neutral small molecule, toluene, showed no change in retention. Results are presented from investigations of model peptides and proteins ranging in size from 1kDa to 30kDa, as well as experiments performed with a silica-based C18 monolith and a polystyrene divinylbenzene monolith functionalized with a phenyl stationary phase. This work indicates that protein separations in monoliths are highly pressure sensitive, and pressure should therefore be considered as an additional parameter in method development for optimizing retention and selectivity. Given these findings, and the ever-increasing importance of chromatographic separations of proteins in both industrial and academic laboratories, improved instrumentation and mechanisms for directly controlling system backpressure could be of great practical value. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Identification and quantification of flavonoids in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, S. E.; Freese, R.; Cornett, Claus

    2000-01-01

    by column-switching, using the first column (a Zorbax 300SB C-3 column) for sample cleanup and eluting the heart-cut flavonoid fraction onto the second column (a Zorbax SE C-18 column) for separation and detection by ultraviolet and atmospheric pressure chemical ionization MS using single ion monitoring...

  13. Analysis of polycyclic aromatic hydrocarbons I. Determination by gas chromatography with glass and fused silica capillary columns; Analisis de Hidrocarburos aromaticos policiclicos. I. Determinacion por cromatografia de gases con columnas capilares de vidrio de silice fundida

    Energy Technology Data Exchange (ETDEWEB)

    Perez, M. M.; Gonzalez, D.

    1987-07-01

    A study of the analysis by gas chromatography of aromatic polycyclic hydrocarbons is presented. The separation has been carried out by glass and fused silica capillary column. The limitations and the advantages of the procedure are discussed in terms of separation efficiency, sensitivity and precision. (Author) 17 refs.

  14. Determination of the total concentration of highly protein-bound drugs in plasma by on-line dialysis and column liquid chromatography : application to non-steroidal anti-inflammatory drugs

    NARCIS (Netherlands)

    Herráez-Hernández, R; van de Merbel, N C; Brinkman, U A

    1995-01-01

    The potential of on-line dialysis as a sample preparation procedure for compounds highly bound to plasma proteins is evaluated, using non-steroidal anti-inflammatory drugs as model compounds and column liquid chromatography as the separation technique. Different strategies to reduce the degree of

  15. A Laboratory Experiment To Measure Henry's Law Constants of Volatile Organic Compounds with a Bubble Column and a Gas Chromatography Flame Ionization Detector (GC-FID)

    Science.gov (United States)

    Lee, Shan-Hu; Mukherjee, Souptik; Brewer, Brittany; Ryan, Raphael; Yu, Huan; Gangoda, Mahinda

    2013-01-01

    An undergraduate laboratory experiment is described to measure Henry's law constants of organic compounds using a bubble column and gas chromatography flame ionization detector (GC-FID). This experiment is designed for upper-division undergraduate laboratory courses and can be implemented in conjunction with physical chemistry, analytical…

  16. An ultra-sensitive method for the analysis of perfluorinated alkyl acids in drinking water using a column switching high-performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Dasu, Kavitha; Nakayama, Shoji F; Yoshikane, Mitsuha; Mills, Marc A; Wright, J Michael; Ehrlich, Shelley

    2017-04-21

    In epidemiological research, it has become increasingly important to assess subjects' exposure to different classes of chemicals in multiple environmental media. It is a common practice to aliquot limited volumes of samples into smaller quantities for specific trace level chemical analyses. A novel method was developed for the determination of 14 perfluorinated alkyl acids (PFAAs) in small volumes (10mL) of drinking water using off-line solid phase extraction (SPE) pre-treatment followed by on-line pre-concentration on a WAX column before analysis on column-switching high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). In general, large volumes (100-1000mL) have been used for the analysis of PFAAs in drinking water. The current method requires approximately 10mL of drinking water concentrated by using an SPE cartridge and eluted with methanol. A large volume injection of the extract was introduced on to a column-switching HPLC-MS/MS using a mix-mode SPE column for the trace level analysis of PFAAs in water. The recoveries for most of the analytes in the fortified laboratory blanks ranged from 73±14% to 128±5%. The lowest concentration minimum reporting levels (LCMRL) for the 14 PFAAs ranged from 0.59 to 3.4ng/L. The optimized method was applied to a pilot-scale analysis of a subset of drinking water samples from an epidemiological study. These samples were collected directly from the taps in the households of Ohio and Northern Kentucky, United States and the sources of drinking water samples are both surface water and ground water, and supplied by different water distribution facilities. Only five PFAAs, perfluoro-1-butanesulfonic acid (PFBS), perfluoro-1- -hexanesulfonic acid (PFHxS), perfluoro-1-octanesulfonic acid (PFOS), perfluoro-n-heptanoic acid (PFHpA) and perfluoro-n-octanoic acid (PFOA) are detected above the LCMRL values. The median concentrations of these five PFAAs detected in the samples was ≤4.1ng/L with PFOS at 7.6ng

  17. Evaluation of the chiral recognition properties and the column performances of three chiral stationary phases based on cellulose for the enantioseparation of six dihydropyridines by high-performance liquid chromatography.

    Science.gov (United States)

    Yu, Jia; Tang, Jing; Yuan, Xiaowei; Guo, Xingjie; Zhao, Longshan

    2017-03-01

    Separations of six dihydropyridine enantiomers on three commercially available cellulose-based chiral stationary phases (Chiralcel OD-RH, Chiralpak IB, and Chiralpak IC) were evaluated with high-performance liquid chromatography (HPLC). The best enantioseparation of the six chiral drugs was obtained with a Chiralpak IC (250 × 4.6 mm i.d., 5 μm) column. Then the influence of the mobile phase including an alcohol-modifying agent and alkaline additive on the enantioseparation were investigated and optimized. The optimal mobile phase conditions and maximum resolution for every analyte were as follows respectively: n-hexane/isopropanol (85:15, v/v) for nimodipine (R = 5.80) and cinildilpine (R = 5.65); n-hexane/isopropanol (92:8, v/v) for nicardipine (R = 1.76) and nisoldipine (R = 1.92); and n-hexane/isopropanol/ethanol (97:2:1, v/v/v) for felodipine (R = 1.84) and lercanidipine (R = 1.47). Relative separation mechanisms are discussed based on the separation results, and indicate that the achiral parts in the analytes' structure showed an important influence on the separation of the chiral column. © 2017 Wiley Periodicals, Inc.

  18. Anion-exchange high-performance liquid chromatography with post-column detection for the analysis of phytic acid and other inositol phosphates

    Science.gov (United States)

    Rounds, M. A.; Nielsen, S. S.; Mitchell, C. A. (Principal Investigator)

    1993-01-01

    The use of gradient anion-exchange HPLC, with a simple post-column detection system, is described for the separation of myo-inositol phosphates, including "phytic acid" (myo-inositol hexaphosphate). Hexa-, penta-, tetra-, tri- and diphosphate members of this homologous series are clearly resolved within 30 min. This method should facilitate analysis and quantitation of "phytic acid" and other inositol phosphates in plant, food, and soil samples.

  19. Determination of Phenolic Acids and Flavonoids in Taraxacum formosanum Kitam by Liquid Chromatography-Tandem Mass Spectrometry Coupled with a Post-Column Derivatization Technique

    Directory of Open Access Journals (Sweden)

    Hung-Ju Chen

    2011-12-01

    Full Text Available A liquid chromatography-tandem mass spectrometry method (LC-MS/MS was developed for the determination of phenolic acids and flavonoids in a medicinal Chinese herb Taraxacum formosanum Kitam. Initially, both phenolic acids and flavonoids were extracted with 50% ethanol in a water-bath at 60 °C for 3 h and eventually separated into acidic fraction and neutral fraction by using a C18 cartridge. A total of 29 compounds were separated within 68 min by employing a Gemini C18 column and a gradient solvent system of 0.1% formic acid and acetonitrile at a flow rate of 1.0 mL/min. Based on the retention behavior as well as absorption and mass spectra, 19 phenolic acids and 10 flavonoids were identified and quantified in T. formosanum, with the former ranging from 14.1 μg/g to 10,870.4 μg/g, and the latter from 9.9 μg/g to 325.8 μg/g. For further identification of flavonoids, a post-column derivatization method involving shift reagents such as sodium acetate or aluminum chloride was used and the absorption spectral characteristics without or with shift reagents were compared. An internal standard syringic acid was used for quantitation of phenolic acids, whereas (± naringenin was found suitable for quantitation of flavonoids. The developed LC-MS/MS method showed high reproducibility, as evident from the relative standard deviation (RSD values for intra-day and inter-day variability being 1.0–6.8% and 2.0–7.7% for phenolic acids and 3.7–7.4% and 1.5–8.1% for flavonoids, respectively, and thus may be applied for simultaneous determination of phenolic acids and flavonoids in Chinese herb and nutraceuticals.

  20. Isolation and purification of lignans from Schisandra chinensis by combination of silica gel column and high-speed counter-current chromatography

    Directory of Open Access Journals (Sweden)

    Sun Yu

    2013-01-01

    Full Text Available Silica gel column combined with high-speed counter-current chromatography separation was successfully applied to the separation of schizandrin (I, angeloylgomisin H (II, gomisin A (III, schisantherin C (IV, deoxyschizandrin (V, γ-schisandrin (VI and schisandrin C (VII from the fruits of Schisandra chinensis (Turcz. Baillon. The petroleum ether extracts of the fruits of S. chinensis were pre-separated first on a silica gel column and divided into two fractions as sample 1 and sample 2. 260 mg of sample 1 was separated by HSCCC using petroleum ether-ethyl acetate-methanol-water (10:8:10:8, v/v as the two-phase solvent system and 18.2 mg of schizandrin, 15.7 mg of angeloylgomisin H, 16.5 mg of gomisin A and 16.7 mg of schisantherin C were obtained. 230 mg of sample 2 was separated using petroleum ether-ethyl acetate-methanol-water (10:0.5:10:1, v/v as the two-phase solvent system and 19.7 mg of deoxyschizandrin, 23.4 mg of γ-schisandrin and 18.2 mg of schisandrin C were obtained. The purities of the separated compounds were all over 94% as determined by HPLC. The chemical structures of these compounds were confirmed by ESI-MS and 1H NMR. [Acknowledgments. Natural Science Foundation of China (20872083, scientific and technological major special project (2010ZX09401-302-5-12 and the Key Science and Technology Program of Shandong Province (BS2009SW047

  1. [Determination of iminodiacetic acid and glycine in dehydrogenation products of diethanolamine by pre-column derivatization and high performance liquid chromatography].

    Science.gov (United States)

    Zhang, Lei; Duan, Zhengkang; Zhu, Hongwen; Yin, Ke

    2017-11-08

    An analytical method was developed for the determination of iminodiacetic acid (IDA) and glycine (Gly), the dehydrogenation products of diethanolamine, by high performance liquid chromatography (HPLC) coupled with pre-column derivatization using p -toluenesulfonyl chloride (PTSC) as the derivatization reagent. IDA and Gly reacted with PTSC in the alkaline environment (pH 11) under 45℃ for 15 min. Then the derivatization products were analyzed by HPLC-MS. The separation was carried out on a high performance liquid chromatograph equipped with an ultraviolet detector. A VP-ODS column (200 mm×4.6 mm, 5 μm) was employed using 0.03 mol/L ammonium acetate (pH 5.5)-acetonitrile (87:13, v/v) as mobile phases for isocratic elution at a flow rate of 1 mL/min and detection wavelength of 235 nm. The results showed good linearities for iminodiacetic acid of 900-2100 mg/L, and for glycine of 20-100 mg/L, respectively. The linear correlation coefficients ( R 2 ) were both greater than 0.999. The limits of detection (LODs) of IDA and Gly were 0.0897 mg/L and 0.0262 mg/L and the recoveries were in the range of 98.7%-99.3% and 98.0%-99.5%, respectively. The relative standard deviations (RSDs) of IDA and Gly were in the range of 0.89%-1.23% and 0.95%-1.11% ( n =3). The method has the characteristics of mild reaction conditions and high accuracy, and is well suitable for the determination of IDA and Gly in industrial production.

  2. A new method for rapid determination of indole-3-carbinol and its condensation products in nutraceuticals using core-shell column chromatography method.

    Science.gov (United States)

    Fibigr, Jakub; Šatínský, Dalibor; Havlíková, Lucie; Solich, Petr

    2016-02-20

    Indole-3-carbinol is a natural glucosinolate known for prevention of human breast, prostate and other types of cancer and it started to be used in commercial preparations, as food supplements. However no analytical method has been proposed for quality control of nutraceuticals with this substance yet. In this paper a new high-performance liquid chromatography (HPLC) method using core-shell column for separation of indole-3-carbinol and its condensation/degradation products was developed and used for the quantitative determination of indole-3-carbinol in nutraceuticals. Separation of indole-3-carbinol, its condensation/degradation products and internal standard ethylparaben was performed on the core-shell column Kinetex 5μ XB-C18 100A (100×4.6mm), particle size 5.0μm, with mobile phase acetonitrile/water according to the gradient program at a flow rate of 1.25mLmin(-1) and at temperature 50°C. The detection wavelength was set at 270nm. Under the optimal chromatographic conditions good linearity of determination was achieved. Available commercial samples of nutraceuticals were extracted with 100% methanol using ultrasound bath. A 5-μL sample volume of the supernatant was directly injected into the HPLC system. The developed method provided rapid and accurate tool for quality control of nutraceuticals based on cruciferous vegetable extracts with indole-3-carbinol content. The presented study showed that the declared content of indole-3-carbinol significantly varied in the different nutraceuticals available on the market. Two analyzed preparations showed the presence of condensation/degradation products of indole-3-carbinol which were not officially declared by the manufacturer. Moreover, further two analyzed nutraceutical preparations showed absolutely no content of declared amount of indole-3-carbinol. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Determination of Myo-Inositol in Infant, Pediatric, and Adult Formulas by Liquid Chromatography-Pulsed Amperometric Detection with Column Switching: Collaborative Study, Final Action 2011.18.

    Science.gov (United States)

    Butler-Thompson, Linda D; Jacobs, Wesley A; Schimpf, Karen J

    2015-01-01

    AOAC First Action Method 2011.18, Myo-Inositol (Free and Bound as Phosphatidylinositol) in Infant and Pediatric Formulas and Adult Nutritionals, was collaboratively studied. With this method free myo-inositol and phosphatidylinositol bound myo-inositol are extracted using two different sample preparation procedures, separated by ion chromatography using a combination of Dionex Carbo Pac PA1 and MA1 columns with column switching, and detected with pulsed amperometry using a gold electrode. Free myo-inositol is extracted from samples with dilute hydrochloric acid and water. Phosphatidylinositol is extracted from samples with chloroform and separated from other fats with silica SPE cartridges. Myo-inositol is then released from the glycerol backbone with concentrated acetic and hydrochloric acids at 120°C. During this collaborative study, nine laboratories from five different countries analyzed blind duplicates of nine infant and pediatric nutritional formulas for both free and phosphatidylinositol bound myo-inositol, and one additional laboratory only completed the free myo-inositol analyses. The method demonstrated acceptable repeatability and reproducibility and met the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) Standard Method Performance Requirements (SMPRs®) for free myo-inositol plus phosphatidylinositol bound myo-inositol for all the matrixes analyzed. SMPRs for repeatability were ≤5% RSD at myo-inositol concentrations of 2-68 mg/100 g ready-to-feed (RTF) liquid. SMPRs for reproducibility were ≤8% RSD in products with myo-inositol concentrations ranging from 2 to 68 mg/100 g RTF liquid. During this collaborative study, repeatability RSDs ranged from 0.51 to 3.22%, and RSDs ranged from 2.66 to 7.55% for free myo-inositol plus phosphatidylinositol bound myo-inositol.

  4. Simultaneous identification and quantification of tetrodotoxin in fresh pufferfish and pufferfish-based products using immunoaffinity columns and liquid chromatography/quadrupole-linear ion trap mass spectrometry

    Science.gov (United States)

    Guo, Mengmeng; Wu, Haiyan; Jiang, Tao; Tan, Zhijun; Zhao, Chunxia; Zheng, Guanchao; Li, Zhaoxin; Zhai, Yuxiu

    2017-07-01

    In this study, we established a comprehensive method for simultaneous identification and quantification of tetrodotoxin (TTX) in fresh pufferfish tissues and pufferfish-based products using liquid chromatography/quadrupole-linear ion trap mass spectrometry (LC-QqLIT-MS). TTX was extracted by 1% acetic acid-methanol, and most of the lipids were then removed by freezing lipid precipitation, followed by purification and concentration using immunoaffinity columns (IACs). Matrix effects were substantially reduced due to the high specificity of the IACs, and thus, background interference was avoided. Quantitation analysis was therefore performed using an external calibration curve with standards prepared in mobile phase. The method was evaluated by fortifying samples at 1, 10, and 100 ng/g, respectively, and the recoveries ranged from 75.8%-107%, with a relative standard deviation of less than 15%. The TTX calibration curves were linear over the range of 1-1 000 μg/L, with a detection limit of 0.3 ng/g and a quantification limit of 1 ng/g. Using this method, samples can be further analyzed using an information-dependent acquisition (IDA) experiment, in the positive mode, from a single liquid chromatography-tandem mass spectrometry injection, which can provide an extra level of confirmation by matching the full product ion spectra acquired for a standard sample with those from an enhanced product ion (EPI) library. The scheduled multiple reaction monitoring method enabled TTX to be screened for, and TTX was positively identified using the IDA and EPI spectra. This method was successfully applied to analyze a total of 206 samples of fresh pufferfish tissues and pufferfish-based products. The results from this study show that the proposed method can be used to quantify and identify TTX in a single run with excellent sensitivity and reproducibility, and is suitable for the analysis of complex matrix pufferfish samples.

  5. Assembly for connecting the column ends of two capillary columns

    International Nuclear Information System (INIS)

    Kolb, B.; Auer, M.; Pospisil, P.

    1984-01-01

    In gas chromatography, the column ends of two capillary columns are inserted into a straight capillary from both sides forming annular gaps. The capillary is located in a tee out of which the capillary columns are sealingly guided, and to which carrier gas is supplied by means of a flushing flow conduit. A ''straight-forward operation'' having capillary columns connected in series and a ''flush-back operation'' are possible. The dead volume between the capillary columns can be kept small

  6. Improved Thermal Modulator for Gas Chromatography

    Science.gov (United States)

    Hasselbrink, Ernest Frederick, Jr.; Hunt, Patrick J.; Sacks, Richard D.

    2008-01-01

    An improved thermal modulator has been invented for use in a variant of gas chromatography (GC). The variant in question denoted as two-dimensional gas chromatography (2DGC) or GC-GC involves the use of three series-connected chromatographic columns, in the form of capillary tubes coated interiorly with suitable stationary phases (compounds for which different analytes exhibit different degrees of affinity). The two end columns are relatively long and are used as standard GC columns. The thermal modulator includes the middle column, which is relatively short and is not used as a standard GC column: instead, its temperature is modulated to affect timed adsorption and desorption of analyte gases between the two end columns in accordance with a 2DGC protocol.

  7. An improved liquid chromatography/tandem mass spectrometry method for the determination of 8-oxo-7,8-dihydro-2'-deoxyguanosine in DNA samples using immunoaffinity column purification.

    Science.gov (United States)

    Singh, Rajinder; McEwan, Michael; Lamb, John H; Santella, Regina M; Farmer, Peter B

    2003-01-01

    The analysis of 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) represents an important biomarker of oxidative stress. A sensitive method for the detection of 8-oxodG in DNA samples has been developed that utilizes immunoaffinity column purification of 8-oxodG followed by liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) multiple reaction monitoring (MRM) mode analysis. An internal standard of stable-isotopically labelled 8-oxodG containing [(15)N(5)] was added prior to the enzymatic digestion of DNA to deoxynucleosides, which was then subjected to immunoaffinity column purification followed by microbore positive ion LC/MS/MS MRM. The 8-oxo-7,8-dihydroguanine (8-oxoG) base product ion at m/z 168 was monitored following cleavage of the glycosidic bond of the 8-oxodG [M+H](+) ion at m/z 284. Similar determinations were made for [(15)N(5)]8-oxodG by monitoring the [(15)N(5)]8-oxoG base product ion at m/z 173 formed from the [M+H](+) ion at m/z 289. The introduction of the immunoaffinity column purification step into the method represents a significant improvement for the accurate determination of 8-oxodG since all artefactual peaks that are observed following the direct injection of digested DNA onto the LC/MS/MS system are removed. The identity of these artefactual peaks has been confirmed to be 2'-deoxyguanosine (dG), thymidine (dT) and 2'-deoxyadenosine (dA). The presence of these artefactual peaks in MRM mode analysis can be explained as a consequence of a concentration effect due to their considerably higher relative abundance in DNA compared to 8-oxodG. The highest signal intensity was observed for the artefactual peak for dA due to the fact that the adenine base formed an adduct with methanol, which is a constituent of the mobile phase. The resulting [M+H](+) ion at m/z 284 (dA m/z 252 + CH(3)OH m/z 32) gave rise to a product ion at m/z 168 following the loss of deoxyribose in MRM mode analysis. Control calf thymus DNA was digested to

  8. A method for simultaneous determination of 20 Fusarium toxins in cereals by high-resolution liquid chromatography-Orbitrap mass spectrometry with a pentafluorophenyl column.

    Science.gov (United States)

    Tamura, Masayoshi; Mochizuki, Naoki; Nagatomi, Yasushi; Harayama, Koichi; Toriba, Akira; Hayakawa, Kazuichi

    2015-05-14

    A high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitrap MS) method was developed for simultaneous determination of 20 Fusarium toxins (nivalenol, fusarenon-X, deoxynivalenol, 3-acetyl deoxynivalenol, 15-acetyl deoxynivalenol, HT-2 toxin, T-2 toxin, neosolaniol, diacetoxyscirpenol, fumonisin B1, fumonisin B2, fumonisin B3, fumonisin A1, fumonisin A2, fumonisin A3, zearalenone, α-zearalenol, β-zearalenol, α-zearalanol, and β-zearalanol) in cereals. The separation of 20 Fusarium toxins with good peak shapes was achieved using a pentafluorophenyl column, and Orbitrap MS was able to detect accurately from cereal matrix components within ±0.77 ppm. The samples were prepared using a QuEChERS kit for extraction and a multifunctional cartridge for purification. The linearity, repeatability, and recovery of the method were >0.9964, 0.8%-14.7%, and 71%-106%, respectively. Using this method, an analysis of 34 commercially available cereals detected the presence of deoxynivalenol, 15-acetyl deoxynivalenol, fumonisin B1, fumonisin B2, fumonisin B3, fumonisn A1, fumonisin A2, fumonisin A3, and zearalenone in corn samples with high concentration and frequency. Trichothecenes was detected from wheat samples with high frequency; in particular, the concentration of deoxynivalenol was high. Conversely, α-zearalenol, β-zearalenol, α-zearalanol, and β-zearalanol were not detected in any of the samples.

  9. A Method for Simultaneous Determination of 20 Fusarium Toxins in Cereals by High-Resolution Liquid Chromatography-Orbitrap Mass Spectrometry with a Pentafluorophenyl Column

    Directory of Open Access Journals (Sweden)

    Masayoshi Tamura

    2015-05-01

    Full Text Available A high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitrap MS method was developed for simultaneous determination of 20 Fusarium toxins (nivalenol, fusarenon-X, deoxynivalenol, 3-acetyl deoxynivalenol, 15-acetyl deoxynivalenol, HT-2 toxin, T-2 toxin, neosolaniol, diacetoxyscirpenol, fumonisin B1, fumonisin B2, fumonisin B3, fumonisin A1, fumonisin A2, fumonisin A3, zearalenone, α-zearalenol, β-zearalenol, α-zearalanol, and β-zearalanol in cereals. The separation of 20 Fusarium toxins with good peak shapes was achieved using a pentafluorophenyl column, and Orbitrap MS was able to detect accurately from cereal matrix components within ±0.77 ppm. The samples were prepared using a QuEChERS kit for extraction and a multifunctional cartridge for purification. The linearity, repeatability, and recovery of the method were >0.9964, 0.8%–14.7%, and 71%–106%, respectively. Using this method, an analysis of 34 commercially available cereals detected the presence of deoxynivalenol, 15-acetyl deoxynivalenol, fumonisin B1, fumonisin B2, fumonisin B3, fumonisn A1, fumonisin A2, fumonisin A3, and zearalenone in corn samples with high concentration and frequency. Trichothecenes was detected from wheat samples with high frequency; in particular, the concentration of deoxynivalenol was high. Conversely, α-zearalenol, β-zearalenol, α-zearalanol, and β-zearalanol were not detected in any of the samples.

  10. Development of molecularly imprinted column-on line-two dimensional liquid chromatography for rapidly and selectively monitoring estradiol in cosmetics.

    Science.gov (United States)

    Guo, Pengqi; Xu, Xinya; Xian, Liang; Ge, Yanhui; Luo, Zhimin; Du, Wei; Jing, Wanghui; Zeng, Aiguo; Chang, Chun; Fu, Qiang

    2016-12-01

    Nowadays, the illegal use of estradiol in cosmetics has caused a series of events which endangering public health seriously. Therefore, it is imperative to establish a simple, fast and specific method for monitoring the illegal use of estradiol in cosmetics. In current study, we developed a molecular imprinted monolithic column two dimensional liquid chromatography method (MIMC-2D-LC) for rapid and selective determination of estradiol in various cosmetic samples. The best polymerization, morphology, structure property, surface groups, and the adsorption performance of the prepared material were investigated. The MIMC-2D-LC was validated and successfully used for detecting estradiol in cosmetic samples with good selectivity, sensitivity, efficiency and reproducibility. The linear range of the MIMC-2D-LC for estradiol was 0.5-50μgg -1 with the limit of detection of 0.08μgg -1 . Finally, six batches of cosmetic samples obtained from local markets were tested by the proposed method. The test results showed that the illegal use of estradiol still existed in the commercially available samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Fully automated dynamic in-syringe liquid-phase microextraction and on-column derivatization of carbamate pesticides with gas chromatography/mass spectrometric analysis.

    Science.gov (United States)

    Lee, Jingyi; Lee, Hian Kee

    2011-09-01

    A new fully automated dynamic in-syringe liquid-phase microextraction (LPME) and on-column derivatization approach, with gas chromatography/mass spectrometric (GC/MS) analysis, was developed to determine carbamate pesticides from water samples. With the use of a CTC CombiPal autosampler and its associated Cycle Composer software, a sample preparation-GC/MS method was enabled that allowed sample extraction, extract injection, and analyte derivatization to be carried out completely automatically. Optimization of extraction parameters was carried out by orthogonal array design which required a minimum of 16 experiments; the entire set of experiments was performed completely automatically and consecutively without any human intervention. Low limits of detection ranging from 0.05 to 0.1 μg/L were achieved for the carbamates. Effective enrichment of the analytes at a low concentration of 0.01 mg/L was also achieved (enrichment factors of between 57 and 138). The precision of the optimized method was satisfactory, with relative standard deviations of <6.0% (n = 6). High relative recoveries of between 81 and 125% were obtained when the method was applied to the analysis of real water samples, indicating that the sample matrix had little effect on the developed method. This automated dynamic in-syringe LPME approach demonstrated the feasibility of a complete analytical system comprising sample preparation and GC/MS that might be operated onsite, fully automatically without human intervention.

  12. Analysis of alkyl phosphates in petroleum samples by comprehensive two-dimensional gas chromatography with nitrogen phosphorus detection and post-column Deans switching.

    Science.gov (United States)

    Nizio, Katie D; Harynuk, James J

    2012-08-24

    Alkyl phosphate based gellants used as viscosity builders for fracturing fluids used in the process of hydraulic fracturing have been implicated in numerous refinery-fouling incidents in North America. In response, industry developed an inductively coupled plasma optical emission spectroscopy (ICP-OES) based method for the analysis of total volatile phosphorus in distillate fractions of crude oil; however, this method is plagued by poor precision and a high limit of detection (0.5±1μg phosphorus mL(-1)). Furthermore this method cannot provide speciation information, which is critical for developing an understanding of the challenge of alkyl phosphates at a molecular level. An approach using comprehensive two-dimensional gas chromatography with nitrogen phosphorus detection (GC×GC-NPD) and post-column Deans switching is presented. This method provides qualitative and quantitative profiles of alkyl phosphates in industrial petroleum samples with increased precision and at levels comparable to or below those achievable by ICP-OES. A recovery study in a fracturing fluid sample and a profiling study of alkyl phosphates in four recovered fracturing fluid/crude oil mixtures (flowback) are also presented. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Rapid determination of 12 antibiotics and caffeine in sewage and bioreactor effluent by online column-switching liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Lima Gomes, Paulo C F; Tomita, Inês N; Santos-Neto, Álvaro J; Zaiat, Marcelo

    2015-11-01

    This study presents a column-switching solid-phase extraction online-coupled to a liquid chromatography/tandem mass spectrometry (SPE-LC-MS/MS) method for simultaneous analysis of 12 antibiotics (7 sulfonamides and 5 fluoroquinolones) and caffeine detected in the sewage and effluent of a pilot anaerobic reactor used in sewage treatment. After acidification and filtration, the samples were directly injected into a simple and conventional LC system. Backflush and foreflush modes were compared based on the theoretical plates and peak asymmetry observed. The method was tested in terms of detection (MDL) and quantification limit (MQL), linearity, relative recovery, and precision intra- and inter-day in lab-made sewage samples. The method presented suitable figures of merit in terms of detection, varying from 8.00 × 10(-5) to 6.00 × 10(-2) ng (0.800 up to 600 ng L(-1); caffeine) with direct injection volume of only 100 μL and 13 min of total analysis time (sample preparation and chromatographic run). When the method was applied in the analysis of sewage and effluent of the anaerobic reactor (n = 15), six antibiotics and caffeine were detected in concentrations ranging from 0.018 to 1097 μg L(-1). To guarantee a reliable quantification, standard addition was used to overcome the matrix effect.

  14. Preparative Isolation of Two Prenylated Biflavonoids from the Roots and Rhizomes of Sinopodophyllum emodi by Sephadex LH-20 Column and High-Speed Counter-Current Chromatography

    Directory of Open Access Journals (Sweden)

    Yan-Jun Sun

    2015-12-01

    Full Text Available Two prenylated biflavonoids, podoverines B–C, were isolated from the dried roots and rhizomes of Sinopodophyllum emodi using a Sephadex LH-20 column (SLHC and high-speed counter-current chromatography (HSCCC. The 95% ethanol extract was partitioned with ethyl acetate in water. Target compounds from the ethyl acetate fraction were further enriched and purified by the combined application of SLHC and HSCCC. n-Hexane–ethyl acetate–methanol–water (3.5:5:3.5:5, v/v was chosen as the two phase solvent system. The flow rate of mobile phase was optimized at 2.0 mL·min−1. Finally, under optimized conditions, 13.8 mg of podoverine B and 16.2 mg of podoverine C were obtained from 200 mg of the enriched sample. The purities of podoverines B and C were 98.62% and 99.05%, respectively, as determined by HPLC. For the first time, podoverins B and C were found in the genus Sinopodophyllum. Their structures were determined by spectroscopic methods (HR-ESI-MS, 1H-NMR, 13C-NMR, HSQC, HMBC. Their absolute configurations were elucidated by comparison of their experimental and calculated ECD spectra. The cytotoxic activities were evaluated against MCF-7 and HepG2 cell lines. The separation procedures proved to be practical and economical, especially for trace prenylated biflavonoids from traditional Chinese medicine.

  15. Separation and purification of five phenylpropanoid glycosides from Lamiophlomis rotata (Benth.) Kudo by a macroporous resin column combined with high-speed counter-current chromatography.

    Science.gov (United States)

    Yue, Hui-Lan; Zhao, Xiao-Hui; Mei, Li-Juan; Shao, Yun

    2013-09-01

    Five phenylethanoid glycosides (PhGs), forsythoside B, verbascoside, alyssonoside, isoverbascoside, and leucosceptoside B, were isolated and purified from Lamiophlomis rotata (Benth.) Kudo by high-speed counter-current chromatography (HSCCC) combined with macroporous resin (MR) column separation. In the present study, the two-phase solvent system composed of ethyl acetate/n-butanol/water (13:3:10, v/v/v) was used for HSCCC separation. A total of 27 mg of forsythoside B, 41 mg of verbascoside, 29 mg of alyssonoside, 23 mg of isoverbascoside, and 13 mg of leucosceptoside B with purities of 97.7, 99.2, 99.5, 99.3, and 97.3%, respectively, were obtained in a one-step separation within 4 h from 150 mg of crude extract. The recoveries of the five PhGs after MR-HSCCC separation were 74.5, 76.5, 72.5, 76.4, and 77.0%, respectively. The chemical structures of all five compounds were identified by (1) H and (13) C NMR spectroscopy. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Large volume cold on-column injection for gas chromatography-negative chemical ionization-mass spectrometry analysis of selected pesticides in air samples.

    Science.gov (United States)

    Bailey, Renata; Belzer, Wayne

    2007-02-21

    A new gas chromatographic method is described for the analysis of fungicides captan, captafol, and folpet from organic extracts of air samples using large volume injection (LVI) via a cold on-column (COC) inlet coupled with gas chromatography-negative chemical ionization-mass spectrometry (GC-NCI-MS). Although standard split/splitless injection due to high injection port temperatures (>225 degrees C) have been shown to degrade these thermally labile fungicides, COC injection minimizes degradation. Insecticides such as chlorpyrifos and diazinon were also examined to show added selectivity. By using a solvent vapor exit with the COC inlet, injection volumes of 10-100 microL can be made to lower detection levels. GC-NCI-MS was compared to GC-electron impact ionization-mass spectrometry for each pesticide using LVI-COC injections and was found to be 2-80 times more sensitive, depending on the pesticide. Method detection limit (MDL) values with 100 microL injections were 2.5 microg L-1 for captan, folpet, and diazinon, 5.0 microg L-1 captafol, and 1.0 microg L-1 for chlorpyrifos, with the normal working range examined for sample analysis from MDL to 100 microg L-1. Detection of all pesticides except captafol, used only in the United States but not Canada, was demonstrated from air samples taken from Abbotsford, British Columbia, Canada.

  17. Fast analysis of curcuminoids from turmeric (Curcuma longa L.) by high-performance liquid chromatography using a fused-core column.

    Science.gov (United States)

    Osorio-Tobón, J Felipe; Carvalho, Pedro I N; Barbero, Gerardo Fernández; Nogueira, Gislaine Chrystina; Rostagno, Mauricio Ariel; Meireles, Maria Angela de Almeida

    2016-06-01

    The recent development of fused-core technology in HPLC columns is enabling faster and highly efficient separations. This technology was evaluated for the development of a fast method for the analysis of main curcuminoids (curcumin, demethoxycurcumin and bisdemethoxycurcumin) present in extracts of turmeric (Curcuma longa L.). A step-by-step strategy was used to optimize temperature (40-55 °C), flow rate (1.0-2.5 mL min(-1)), mobile phase composition and equilibration time (1-5 min). A gradient method was developed using acidified water and acetonitrile combined with high column temperature (55 °C) and flow rate (2.5 mL min(-1)). Optimized conditions provided a method for the separation of these three curcuminoids in approximately 1.3 min with a total analysis time (sample-to-sample) of 7 min, including the clean-up and the re-equilibration of the column. Evaluation of chromatographic performance revealed excellent intraday and interday reproducibility (>99%), resolution (>2.23), selectivity (>1.12), peak symmetry (1.24-1.42) while presenting low limits of detection (turmeric rhizome and products that use turmeric in their formulation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. The fabrication of monolithic capillary column based on poly (bisphenol A epoxy vinyl ester resin-co-ethylene glycol dimethacrylate) and its applications for the separation of small molecules in high performance liquid chromatography.

    Science.gov (United States)

    Niu, Wenjing; Wang, Lijuan; Bai, Ligai; Yang, Gengliang

    2013-07-05

    A new polymeric monolith was synthesized in fused-silica capillary by in situ polymerization technique. In the polymerization, bisphenol A epoxy vinyl ester resin (VER) was used as the functional monomer, ethylene glycol dimethacrylate (EDMA) as the crosslinking monomer, 1,4-butanediol, 1-propanol and water as the co-porogens, and azobisisobutyronitrile (AIBN) as the initiator. The conditions of polymerization have been optimized. Morphology of the prepared poly (VER-co-EDMA) monolith was investigated by the scanning electron microscopy (SEM); pore properties were assayed by mercury porosimetry and nitrogen adsorption. The optimized poly (VER-co-EDMA) monolith showed a uniform structure, good permeability and mechanical stability. Then, the column was used as the stationary phase of high performance liquid chromatography (HPLC) to separate the mixture of benzene derivatives. The best column efficiency achieved for phenol was 235790 theoretical plates per meter. Baseline separations of benzene derivatives and halogenated benzene compounds under optimized isocratic mode conditions were achieved with high column efficiency. The column showed good reproducibility: the relative standard deviation (RSD) values based on the retention times (n=3) for run-to-run, column-to-column and batch-to-batch were less than 0.98, 1.68, 5.48%, respectively. Compared with poly (BMA-co-EDMA) monolithic column, the proposed monolith exhibited more efficiency in the separation of small molecules. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Separation of three anthraquinone glycosides including two isomers by preparative high-performance liquid chromatography and high-speed countercurrent chromatography from Rheum tanguticum Maxim. ex Balf.

    Science.gov (United States)

    Chen, Tao; Li, Hongmei; Zou, Denglang; Liu, Yongling; Chen, Chen; Zhou, Guoying; Li, Yulin

    2016-08-01

    Anthraquinone glycosides, such as chrysophanol 1-O-β-d-glucoside, chrysophanol 8-O-β-d-glucoside, and physion 8-O-β-d-glucoside, are the accepted important active components of Rheum tanguticum Maxim. ex Balf. due to their pharmacological properties: antifungal, antimicrobial, cytotoxic, and antioxidant activities. However, an effective method for the separation of the above-mentioned anthraquinone glycosides from this herb is not currently available. Especially, greater difficulty existed in the separation of the two isomers chrysophanol 1-O-β-d-glucoside and chrysophanol 8-O-β-d-glucoside. This study demonstrated an efficient strategy based on preparative high-performance liquid chromatography and high-speed countercurrent chromatography for the separation of the above-mentioned anthraquinone glycosides from Rheum tanguticum Maxim.ex Balf. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextraction and liquid chromatography with post-column derivatization.

    Science.gov (United States)

    Miralles, Pablo; Chisvert, Alberto; Alonso, M José; Hernandorena, Sandra; Salvador, Amparo

    2018-03-30

    An analytical method for the determination of traces of formaldehyde in cosmetic products containing formaldehyde-releasing preservatives has been developed. The method is based on reversed-phase dispersive liquid-liquid microextraction (RP-DLLME), that allows the extraction of highly polar compounds, followed by liquid chromatography-ultraviolet/visible (LC-UV/vis) determination with post-column derivatization. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the selected conditions, a mixture of 500 μL of acetonitrile (disperser solvent) and 50 μL of water (extraction solvent) was rapidly injected into 5 mL of toluene sample solution. The extracts were injected into the LC-UV/vis system using phosphate buffer 6 mmol L -1 at pH 2 as mobile phase. After chromatographic separation, the eluate merged with a flow stream of pentane-2,4-dione in ammonium acetate solution as derivatizing reagent and passed throughout a post-column reactor at 85 °C in order to derivatize formaldehyde into 3,5-diacetyl-1,4-dihydrolutidine, according to Hantzsch reaction, which was finally measured spectrophotometrically at 407 nm. The method was successfully validated showing good linearity, an enrichment factor of 86 ± 2, limits of detection and quantification of 0.7 and 2.3 ng mL -1 , respectively, and good repeatability (RSD < 9.2%). Finally, the proposed analytical method was applied to the determination of formaldehyde in different commercial cosmetic samples containing formaldehyde-releasing preservatives, such as bronopol, diazolidinyl urea, imidazolidinyl urea, and DMDM hydantoin, with good relative recovery values (91-113%) thus showing that matrix effects were negligible. The good analytical features of the proposed method besides of its simplicity and affordability, make it useful to carry out the quality control of cosmetic products containing formaldehyde-releasing preservatives. Copyright

  1. 1,4-Anthraquinone: A new useful pre-column reagent for the determination of N-acetylcysteine and captopril in pharmaceuticals by high performance liquid chromatography.

    Science.gov (United States)

    Gatti, Rita; Morigi, Rita

    2017-09-05

    1,4-Anthraquinone (ANQ) is proposed as a novel pre-column reagent for high performance liquid chromatography (HPLC) determination of N-acetylcysteine (NAC) and captopril (CAP) in pharmaceutical formulations. The derivatization reactions were carried out at room temperature: NAC at pH 8 for 1min, while CAP at pH 7.5 for 20min. Both reactions reached completeness at a reagent to thiol molar ratio of about 2.5. The synthesised derivatives were characterized by 1 H NMR and IR. The chromatographic separations were performed on a C 18 Phenomenex Synergi Fusion 4μm (250mm×4.6mm I.D.) stainless steel column with detection at λ=300nm. The mobile phase consisted of methanol/triethylammonium (TEA) phosphate buffer (pH 3; 0.05mol/L) 75:25 (v/v) at a flow-rate of 0.4mL/min for NAC and 88:12 (v/v), at a flow-rate of 0.6mL/min for CAP. The validation parameters (linearity, sensitivity, accuracy, precision, specificity and stability) were highly satisfactory. Linear response was observed (determination coefficient ≥0.9996). Detection limits were about 8 and 18ng/mL for NAC and CAP, respectively. Intra-day precision (relative standard deviation, R.S.D.) was ≤1.58%, for thiol to internal standard (IS) peak area ratio and ≤0.33%, for thiol and IS retention times (t R ), without significant differences between intra- and inter-day data. Thiol recovery studies were satisfactory (99.50%) with R.S.D. ≤0.56%. The results highlight the high sensitivity of the method and the remarkable reactivity and selectivity of the reagent towards the thiol function. The developed method is suitable for the quality control of both thiols in commercial products. The method can be applied in any analytical laboratory not requiring a sophisticated instrumentation. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Liquid Chromatography with a Fluorimetric Detection Method for Analysis of Paralytic Shellfish Toxins and Tetrodotoxin Based on a Porous Graphitic Carbon Column

    Directory of Open Access Journals (Sweden)

    Veronica Rey

    2016-06-01

    Full Text Available Paralytic shellfish toxins (PST traditionally have been analyzed by liquid chromatography with either pre- or post-column derivatization and always with a silica-based stationary phase. This technique resulted in different methods that need more than one run to analyze the toxins. Furthermore, tetrodotoxin (TTX was recently found in bivalves of northward locations in Europe due to climate change, so it is important to analyze it along with PST because their signs of toxicity are similar in the bioassay. The methods described here detail a new approach to eliminate different runs, by using a new porous graphitic carbon stationary phase. Firstly we describe the separation of 13 PST that belong to different groups, taking into account the side-chains of substituents, in one single run of less than 30 min with good reproducibility. The method was assayed in four shellfish matrices: mussel (Mytillus galloprovincialis, clam (Pecten maximus, scallop (Ruditapes decussatus and oyster (Ostrea edulis. The results for all of the parameters studied are provided, and the detection limits for the majority of toxins were improved with regard to previous liquid chromatography methods: the lowest values were those for decarbamoyl-gonyautoxin 2 (dcGTX2 and gonyautoxin 2 (GTX2 in mussel (0.0001 mg saxitoxin (STX·diHCl kg−1 for each toxin, decarbamoyl-saxitoxin (dcSTX in clam (0.0003 mg STX·diHCl kg−1, N-sulfocarbamoyl-gonyautoxins 2 and 3 (C1 and C2 in scallop (0.0001 mg STX·diHCl kg−1 for each toxin and dcSTX (0.0003 mg STX·diHCl kg−1 in oyster; gonyautoxin 2 (GTX2 showed the highest limit of detection in oyster (0.0366 mg STX·diHCl kg−1. Secondly, we propose a modification of the method for the simultaneous analysis of PST and TTX, with some minor changes in the solvent gradient, although the detection limit for TTX does not allow its use nowadays for regulatory purposes.

  3. SENSITIVE METHOD FOR THE DETERMINATION OF VINCRISTINE IN HUMAN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AFTER ONLINE COLUMN-EXTRACTION

    NARCIS (Netherlands)

    BLOEMHOF, H; VANDIJK, KN; DEGRAAF, SSN; VENDRIG, DEMM; UGES, DRA

    1991-01-01

    A column-switching high-performance liquid chromatographic method was developed for the determination of vincristine in serum. Sample preparation was carried out by means of on-line column-extraction, using a C18 reversed-phase preconcentration column. This technique is simple (minimizing manual

  4. Lewisite Metabolites in Urine by Solid Phase Extraction-Dual Column Reversed-Phase Liquid Chromatography-Isotope Dilution Tandem Mass Spectrometry.

    Science.gov (United States)

    Palcic, Jason D; Donovan, Stephen F; Jones, Janet S; Flagg, E Lindsay; Salonga, Redentor A; Mock, Walter E; Asirvatham, Victor S

    2016-07-01

    Lewisite (2-chlorovinyldichloroarsine) is a chemical warfare agent developed during World War I. A quantitative method using solid phase extraction (SPE) followed by dual column liquid chromatography (LC)-isotope dilution tandem mass spectrometry (MS-MS) was developed for the determination of (2-chlorovinyl)arsonic acid (CVAOA), a metabolite of Lewisite, in human urine. The sample was treated with hydrogen peroxide to oxidize any (2-chlorovinyl)arsonous acid (CVAA) that remained in the trivalent arsenic oxidation state. There was 1.19% (arsenic purity) of bis-(2-chlorovinyl)arsinic acid (BCVAOA), a minor Lewisite metabolite, in the stock CVAA material. The high-throughput method qualitatively assessed BCVAOA simultaneously utilizing normal-phase silica SPE followed by reversed-phase C18 LC for an orthogonal separation. The chromatographic method results in a 5.8-min cycle time with adequate retention (k' = 2.4) of CVAOA. The mass spectrometer was operated in positive electrospray ionization mode with quantitative m/z 186.9→61.0 and confirmation 186.9→91.0 mass transitions. This selective method demonstrated linearity, accuracy and reproducibility for the clinically relevant calibration range (25-3,200 µg/L as CVAA). The method detection limit was 3.3 µg/L as CVAA from a 10 µL injection. This LC-MS-MS emergency response method has a throughput of >240 samples (2.5 extracted 96-well plates) per day. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Determination of hexavalent chromium concentration in industrial waste incinerator stack gas by using a modified ion chromatography with post-column derivatization method.

    Science.gov (United States)

    Miyake, Yuichi; Tokumura, Masahiro; Iwazaki, Yuta; Wang, Qi; Amagai, Takashi; Horii, Yuichi; Otsuka, Hideyuki; Tanikawa, Noboru; Kobayashi, Takeshi; Oguchi, Masahiro

    2017-06-16

    An ion chromatography with post-column derivatization with 1,5-diphenylcarbazide (IC-DPC) analytical method was modified to enable measurement of trace-level hexavalent chromium (Cr(VI)) in air. One of the difficulties in determining trace levels of Cr(VI) in air with conventional IC-DPC methods is co-elution of the solvent and ion peaks due to high concentrations of ionic compounds in the extract. However, by using gradient elution rather than isocratic elution we were able to fully resolve the Cr(VI) ion peak from the solvent peak without the need for diluting the extract, which would have reduced the minimum quantifiable level of the method. With this method, we were able to detect Cr(VI) in air at concentrations of 5.3ng/m 3 (assuming a sampling volume of 1m 3 and a final solution volume of 10mL). Recovery tests at three different concentrations of Cr(VI) (50, 250, 1000ng) were performed with or without fly ash; recovery rates at all the concentrations of Cr(VI), with or without fly ash, ranged from 68% to 110% (mean±relative standard deviation, 96%±11%), and there were no differences in recovery rates with respect to the presence or absence of fly ash. Finally, we used the developed method to determine the concentration of Cr(VI) in stack gases collected from eight industrial waste incinerators located in Japan. The concentration of Cr(VI) in the stack gases ranged from below the method quantification limit to 3100ng/m 3 . The highest concentrations of Cr(VI) detected in the stack gases were two to three orders of magnitude higher than that in ambient air in Japan. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Temperature-based on-column solute focusing in capillary liquid chromatography reduces peak broadening from precolumn dispersion and volume overload when used alone or with solvent-based focusing

    Science.gov (United States)

    Groskreutz, Stephen R.; Horner, Anthony R.; Weber, Stephen G.

    2015-01-01

    On-column focusing is essential for satisfactory performance using capillary scale columns. On-column focusing results from generating transient conditions at the head of the column that lead to high solute retention. Solvent-based on-column focusing is a well-known approach to achieve this. Temperature-assisted on-column focusing (TASF) can also be effective. TASF improves focusing by cooling a short segment of the column inlet to a temperature that is lower than the column temperature during the injection and then rapidly heating the focusing segment to the match the column temperature. A troublesome feature of an earlier implementation of TASF was the need to leave the capillary column unpacked in that portion of the column inside the fitting connecting it to the injection valve. We have overcome that problem in this work by packing the head of the column with solid silica spheres. In addition, technical improvements to the TASF instrumentation include: selection of a more powerful thermo-electric cooler to create faster temperature changes and electronic control for easy incorporation into conventional capillary instruments. Used in conjunction with solvent-based focusing and with isocratic elution, volumes of paraben samples (esters of p-hydroxybenzoic acid) up to 4.5-times the column liquid volume can be injected without significant bandspreading due to volume overload. Interestingly, the shapes of the peaks from the lowest volume injections that we can make, 30 nL, are improved when using TASF. TASF is very effective at reducing the detrimental effects of precolumn dispersion using isocratic elution. Finally, we show that TASF can be used to focus the neuropeptide galanin in a sample solvent with elution strength stronger than the mobile phase. Here, the stronger solvent is necessitated by the need to prevent peptide adsorption prior to and during analysis. PMID:26091787

  7. Post column derivatisation analyses review. Is post-column derivatisation incompatible with modern HPLC columns?

    Science.gov (United States)

    Jones, Andrew; Pravadali-Cekic, Sercan; Dennis, Gary R; Shalliker, R Andrew

    2015-08-19

    Post Column derivatisation (PCD) coupled with high performance liquid chromatography or ultra-high performance liquid chromatography is a powerful tool in the modern analytical laboratory, or at least it should be. One drawback with PCD techniques is the extra post-column dead volume due to reaction coils used to enable adequate reaction time and the mixing of reagents which causes peak broadening, hence a loss of separation power. This loss of efficiency is counter-productive to modern HPLC technologies, -such as UHPLC. We reviewed 87 PCD methods published from 2009 to 2014. We restricted our review to methods published between 2009 and 2014, because we were interested in the uptake of PCD methods in UHPLC environments. Our review focused on a range of system parameters including: column dimensions, stationary phase and particle size, as well as the geometry of the reaction loop. The most commonly used column in the methods investigated was not in fact a modern UHPLC version with sub-2-micron, (or even sub-3-micron) particles, but rather, work-house columns, such as, 250 × 4.6 mm i.d. columns packed with 5 μm C18 particles. Reaction loops were varied, even within the same type of analysis, but the majority of methods employed loop systems with volumes greater than 500 μL. A second part of this review illustrated briefly the effect of dead volume on column performance. The experiment evaluated the change in resolution and separation efficiency of some weak to moderately retained solutes on a 250 × 4.6 mm i.d. column packed with 5 μm particles. The data showed that reaction loops beyond 100 μL resulted in a very serious loss of performance. Our study concluded that practitioners of PCD methods largely avoid the use of UHPLC-type column formats, so yes, very much, PCD is incompatible with the modern HPLC column. Copyright © 2015. Published by Elsevier B.V.

  8. RpeakChrom: Novel R package for the automated characterization and optimization of column efficiency in high-performance liquid chromatography analysis.

    Science.gov (United States)

    Peris-Díaz, Manuel David; Alcoriza-Balaguer, Maria Isabel; García-Cañaveras, Juan Carlos; Santonja, Francisco; Sentandreu, Enrique; Lahoz, Agustín

    2017-11-01

    Characterization of chromatographic columns using the traditional van Deemter method is limited by the necessity of calculating extra-column variance, issue particularly relevant when modeling asymmetrical peaks eluted from monolithic columns. A novel R package that implements Parabolic Variance Modified Gaussian approach for accurate peak modeling, van Deemter equation and two alternatives approaches, based on van Deemter, has been developed to calculate the height equivalent to a theoretical plate (HETP). To assess package capabilities conventional packed reverse-phase and monolithic HPLC columns were characterized. Peaks eluted from the monolithic column showed a high value of factor asymmetry due, in part, to the contribution of extra-column factors. Such deviation can be circumvented by the two alternatives approaches implemented in the R-package. Furthermore, increased values of eddy diffusion and mass transfer kinetics terms in HETP were observed for the packed column, while accuracy was below 9% in all cases. These results showed the usefulness of the R-package for both modeling chromatographic peaks and assessing column efficiency. The RpeakChrom package could become a helpful tool for testing new stationary phases during column development and to evaluate column during its lifetime. This R tool is freely available from CRAN (https://CRAN.R-project.org/package=RpeakChrom). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Chromatographic selectivity of poly(alkyl methacrylate-co-divinylbenzene) monolithic columns for polar aromatic compounds by pressure-driven capillary liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Shu-Ling; Wang, Chih-Chieh; Fuh, Ming-Ren, E-mail: msfuh@scu.edu.tw

    2016-10-05

    In this study, divinylbenzene (DVB) was used as the cross-linker to prepare alkyl methacrylate (AlMA) monoliths for incorporating π-π interactions between the aromatic analytes and AlMA-DVB monolithic stationary phases in capillary LC analysis. Various AlMA/DVB ratios were investigated to prepare a series of 30% AlMA-DVB monolithic stationary phases in fused-silica capillaries (250-μm i.d.). The physical properties (such as porosity, permeability, and column efficiency) of the synthesized AlMA-DVB monolithic columns were investigated for characterization. Isocratic elution of phenol derivatives was first employed to evaluate the suitability of the prepared AlMA-DVB columns for small molecule separation. The run-to-run (0.16–1.20%, RSD; n = 3) and column-to-column (0.26–2.95%, RSD; n = 3) repeatabilities on retention times were also examined using the selected AlMA-DVB monolithic columns. The π-π interactions between the aromatic ring and the DVB-based stationary phase offered better recognition on polar analytes with aromatic moieties, which resulted in better separation resolution of aromatic analytes on the AlMA-DVB monolithic columns. In order to demonstrate the capability of potential environmental and/or food safety applications, eight phenylurea herbicides with single benzene ring and seven sulfonamide antibiotics with polyaromatic moieties were analyzed using the selected AlMA-DVB monolithic columns. - Highlights: • First investigation on chromatographic selectivity of AlMA-DVB monolithic columns. • Good run-to-run/column-to-column repeatability (<3%) on AlMA-DVB monolithic columns. • Efficient separation of phenylurea herbicides and sulfonamides on AlMA-DVB columns.

  10. Evaluation of fused-core and monolithic versus porous silica-based C18 columns and porous graphitic carbon for ion-pairing liquid chromatography analysis of catecholamines and related compounds.

    Science.gov (United States)

    Chirita, Raluca-Ioana; Finaru, Adriana-Luminita; Elfakir, Claire

    2011-03-15

    This paper evaluates the performances of reversed-phase (RPLC) and ion-pairing chromatography (IPLC) coupled with UV detection for the analysis of a set of 12 catecholamines and related compounds. Different chromatographic columns (porous C18-silica, perfluorinated C18-silica, porous graphitic carbon, monolithic and fused-core silica-based C18 columns) were tested using semi-long perfluorinated carboxylic acids as volatile ion-pairing reagents. Much more promising results were obtained by IPLC than by RPLC and important improvements in analytes peak symmetry and separation resolution were observed when using the "fast chromatography" columns (monolithic and fused-core C18) under IPLC conditions. For UV detection, a satisfactory separation of the 12 selected analytes was achieved in less than 20 min by using a fused-core particles column (Halo C18) and a mobile phase composed of a 1.25 mM nonafluoropentanoic acid aqueous solution and methanol under gradient elution mode. The chromatographic method developed can be directly coupled with electrospray ionization tandem mass spectrometry (ESI-MS/MS) in positive ionization mode and 10 solutes among those selected can be observed. The presence of the acidic ion-pairing reagent in the mobile phase makes this system incompatible with negative ionization mode and thus unable to detect the two acidic compounds that only responded in negative mode. In terms of MS detection, Monolithic C18 column proved to be the best one to reach the lowest detection limits (LODs) (from 0.5 ngmL(-1) to 10 ngmL(-1) depending on the neurotransmitter). The applicability of the optimized LC-MS/MS method to a "real world" sample was finally evaluated. The presence of the matrix leads to signal suppression for several solutes and thus to higher LODs. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. An optimized method for fatty acid analysis, including quantification of trans fatty acids, in human adipose tissue by gas-liquid chromatography

    DEFF Research Database (Denmark)

    Bysted, Anette; Cold, S; Hølmer, Gunhild Kofoed

    1999-01-01

    for 25 min, and finally raised at 25 degrees C/min to 225 degrees C. The trans and cis isomers of18:1 were well separated from each other, as shown by silver-ion thin-layer chromatography. Verification by standardsshowed that the trans 18:1 isomers with a double bond in position 12 or lower were......Considering the need for a quick direct method for measurement of the fatty acid composition including trans isomers ofhuman adipose tissue we have developed a procedure using gas-liquid chromatography (GLC) alone, which is thussuitable for validation of fatty acid status in epidemiological studies...

  12. Quantitative determination of azithromycin in plasma, blood and isolated neutrophils by liquid chromatography using pre-column derivatization with 9-fluorenylmethyloxycarbonyl-chloride and fluorescence detection

    NARCIS (Netherlands)

    Wilms, Erik; Trumpie, Henk; Veenendaal, Wim; Touw, Daan

    2005-01-01

    In this study, a high-performance liquid chromatographic method with pre-column derivatization and fluorescence detection was optimised and validated for the quantification of azithromycin (AZM) in plasma. Clarithromycin (CLM) was used as an internal standard. Pre-column derivatization was done with

  13. "Supermarket Column Chromatography of Leaf Pigments" Revisited: Simple and Ecofriendly Separation of Plant Carotenoids, Chlorophylls, and Flavonoids from Green and Red Leaves

    Science.gov (United States)

    Dias, Alice M.; Ferreira, Maria La Salete

    2015-01-01

    A simple and ecofriendly procedure was developed in order to prepare extracts from red and green leaves. This procedure enables the separation of yellow, green, and red band pigments and optimizes the previously reported baking soda "supermarket column". The same extract also led to a novel and colorful potato starch column, which can…

  14. Identification and quantification of flavonoids in human urine samples by column switching liquid chromatography coupled to atmospheric pressure chemical ionization mass spectrometry

    DEFF Research Database (Denmark)

    Nielsen, Salka E.; Freese, R.; Cornett, C.

    2000-01-01

    A rapid and sensitive high-performance liquid chromatographic mass spectrometric (HPLC-MS) method is described for the determination and quantification of 12 dietary flavonoid glycosides and aglycons in human urine samples. Chromatographic separation of the analytes of interest was achieved...... by column-switching, using the first column (a Zorbax 300SB C-3 column) for sample cleanup and eluting the heart-cut flavonoid fraction onto the second column (a Zorbax SE C-18 column) for separation and detection by ultraviolet and atmospheric pressure chemical ionization MS using single ion monitoring...... of variation for the analysis of the 12 different flavonoids in quality control urine samples were 12.3% on average (range 11.0-13.7%, n = 24, reproducibility) and the repeatability of the assay were 5.0% (mean, range 0.1-14.8%, it = 12). A subset of 10 urine samples from a human dietary intervention study...

  15. Gas chromatography for in situ analysis of a cometary nucleus. II. Analysis of permanent gases and light hydrocarbons with a carbon molecular sieve porous layer open tubular column.

    Science.gov (United States)

    Szopa, C; Sternberg, R; Coscia, D; Raulin, F; Vidal-Madjar, C

    2000-12-22

    Considering the severe constraints of space instrumentation, a great improvement for the in situ gas chromatographic (GC) determination of permanent and noble gases in a cometary nucleus is the use of a new carbon molecular sieve porous layer open tubular (PLOT) column called Carbobond. No exhaustive data dealing with this column being available, studies were carried out to entirely characterize its analytical performances, especially when used under the operating conditions of the cometary sampling and composition (COSAC) experiment of the European Space Agency (ESA) Rosetta space mission to be launched in 2003 for a rendezvous with comet 46 P/Wirtanen in 2011. The high efficiency and speed of analysis of this column at both atmospheric and vacuum outlet column pressure is demonstrated, and the kinetic mass transfer contribution of this carbon molecular sieve adsorbent is calculated. Besides, differential adsorption enthalpies of several gases and light hydrocarbons were determined from the variation of retention volume with temperature. The data indicate close adsorption behaviors on the Carbobond porous layer adsorbent and on the carbon molecular sieve Carboxen support used to prepare the packed columns. Moreover, taking into account the in situ operating conditions of the experiment, a study of two columns with different porous layer thicknesses allowed one to optimize the separation of the target components and to select the column parameters compatible with the instrument constraints. Comparison with columns of similar selectivity shows that these capillary columns are the first ones able to perform the same work as the packed and micro-packed columns dedicated to the separation of this range of compounds in GC space exploration.

  16. Preparation and evaluation of poly(alkyl methacrylate-co-methacrylic acid-co-ethylene dimethacrylate) monolithic columns for separating polar small molecules by capillary liquid chromatography.

    Science.gov (United States)

    Lin, Shu-Ling; Wu, Yu-Ru; Lin, Tzuen-Yeuan; Fuh, Ming-Ren

    2015-04-29

    In this study, methacrylic acid (MAA) was incorporated with alkyl methacrylates to increase the hydrophilicity of the synthesized ethylene dimethacrylate-based (EDMA-based) monoliths for separating polar small molecules by capillary LC analysis. Different alkyl methacrylate-MAA ratios were investigated to prepare a series of 30% alkyl methacrylate-MAA-EDMA monoliths in fused-silica capillaries (250-μm i.d.). The porosity, permeability, and column efficiency of the synthesized MAA-incorporated monolithic columns were characterized. A mixture of phenol derivatives is employed to evaluate the applicability of using the prepared monolithic columns for separating small molecules. Fast separation of six phenol derivatives was achieved in 5 min with gradient elution using the selected poly(lauryl methacrylate-co-MAA-co-EDMA) monolithic column. In addition, the effect of acetonitrile content in mobile phase on retention factor and plate height as well as the plate height-flow velocity curves were also investigated to further examine the performance of the selected poly(lauryl methacrylate-co-MAA-co-EDMA) monolithic column. Moreover, the applicability of prepared polymer-based monolithic column for potential food safety applications was also demonstrated by analyzing five aflatoxins and three phenicol antibiotics using the selected poly(lauryl methacrylate-co-MAA-co-EDMA) monolithic column. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. [Analysis of hydrogen isotopes by gas chromatography using a MnCl2 coated γ-Al2O3 capillary packed column].

    Science.gov (United States)

    Chen, Ping; Fu, Xiaolong; Hu, Peng; Xiao, Chengjian; Ren, Xingbi; Xia, Xiulong; Wang, Heyi

    2017-07-08

    The conventional packed column gas chromatographic analysis of hydrogen isotopes has low column efficiency, broad peak and long retention time. In this work, a γ -Al 2 O 3 with MnCl 2 coated capillary packed column was tested at cryogenic temperature. The systematic column efficiency analysis and the hydrogen isotopes analytical technique research had been carried out. The results showed that, the γ -Al 2 O 3 with MnCl 2 coating could greatly improve the surface degree of order, pore structure and adsorption properties. Also the o -H 2 peak and p -H 2 peak were eluted in a single area. The γ -Al 2 O 3 with MnCl 2 coating was packed into a 0.53 mm inner diameter and 1.0 m long fused silica capillary column. It had a good linear relationship used this column with thermal conductivity detector (TCD) to detect the volume concentrations of hydrogen isotopes from 1 to 10 mL/L, and the relative error was less than 5% for low concentration sample testing. For H 2 , HD and D 2 , the retention times can be shortened to 39, 46 and 60 s, respectively. The limits of detection were reduced to 0.046, 0.067 and 0.072 mL/L, respectively. Compared with conventional packed column, capillary packed column had sharper peak form, higher separation degree of adjacent components, shorter retention time and lower detection limits. The above results indicate that the capillary packed column with TCD detector can be used for fast detection of low concentration of hydrogen isotopes and their online analysis.

  18. Preparation and evaluation of poly(alkyl methacrylate-co-methacrylic acid-co-ethylene dimethacrylate) monolithic columns for separating polar small molecules by capillary liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Shu-Ling; Wu, Yu-Ru; Lin, Tzuen-Yeuan; Fuh, Ming-Ren, E-mail: msfuh@scu.edu.tw

    2015-04-29

    Highlights: • Methacrylic acid (MAA) was used to increase hydrophilicity of polymeric monoliths. • Fast separation of phenol derivatives was achieved in 5 min using MAA-incorporated column. • Separations of aflatoxins and phenicol antibiotics were achieved using MAA-incorporated column. - Abstract: In this study, methacrylic acid (MAA) was incorporated with alkyl methacrylates to increase the hydrophilicity of the synthesized ethylene dimethacrylate-based (EDMA-based) monoliths for separating polar small molecules by capillary LC analysis. Different alkyl methacrylate–MAA ratios were investigated to prepare a series of 30% alkyl methacrylate–MAA–EDMA monoliths in fused-silica capillaries (250-μm i.d.). The porosity, permeability, and column efficiency of the synthesized MAA-incorporated monolithic columns were characterized. A mixture of phenol derivatives is employed to evaluate the applicability of using the prepared monolithic columns for separating small molecules. Fast separation of six phenol derivatives was achieved in 5 min with gradient elution using the selected poly(lauryl methacrylate-co-MAA-co-EDMA) monolithic column. In addition, the effect of acetonitrile content in mobile phase on retention factor and plate height as well as the plate height-flow velocity curves were also investigated to further examine the performance of the selected poly(lauryl methacrylate-co-MAA-co-EDMA) monolithic column. Moreover, the applicability of prepared polymer-based monolithic column for potential food safety applications was also demonstrated by analyzing five aflatoxins and three phenicol antibiotics using the selected poly(lauryl methacrylate-co-MAA-co-EDMA) monolithic column.

  19. An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography - A case study on the determination of bisphenol A in environmental water samples.

    Science.gov (United States)

    Háková, Martina; Chocholoušová Havlíková, Lucie; Chvojka, Jiří; Solich, Petr; Šatínský, Dalibor

    2018-02-01

    Polyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini-column cartridge (5 × 4.6mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-µL sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascentis ® Express C18 (10cm × 4.6mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (λ ex = 225nm and λ em = 320nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500µgL -1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2µgL -1 , respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohře, Labe, Nisa, Úpa, and Opava Rivers). Copyright © 2017 Elsevier B.V. All rights reserved.

  20. [Determination of five avermectins in bovine liver by on-line solid-phase extraction with hydrophobic monolithic column coupled with high performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Li, Xin; Zhang, Yaoqin; Ai, Lianfeng; Wang, Xuesheng; Wang, Manman; Xu, Houjun; Hao, Yulan

    2015-06-01

    A method based on on-line solid-phase extraction (SPE) with hydrophobic monolithic column coupled with high performance liquid chromatography-tandem mass spectrometry was developed for the simultaneous determination of five avermectins in bovine liver. A poly(butyl methacrylate-co-ethylene dimethacrylate) monolithic column was used as the sorbent. The parameters influenced on on-line SPE and separation process such as the loading mobile phase, the eluting flow rate and the solvent for the separation were investigated in detail. Blank samples, spiked samples, matrix effect and recovery experiments were investigated to evaluate the extraction efficiency and potential interfering compounds originating from the matrix. Under the optimized conditions, the method showed a linear range of 1-100 µg/L and the quantification limit of 5 µg/kg for each analyte. The presented method gave recoveries of 77.4%-98.4%. The relative standard deviations of intra-day and inter-day were 4.46%-8.03% and 4.79%-8.68%, respectively. Moreover, no significant changes were found in the extraction performance after more than 400 usages on one monolithic column, and even on the monoliths with various batches. The feasibility of the developed poly (butyl methacrylate-coethylene dimethacrylate) monolithic column based on the on-line SPE method for the determination of avermectins was further demonstrated by the analysis of real samples.

  1. A simple and rapid technique for recovery of 99mTc from low specific activity (n,γ)99Mo based on solid-liquid extraction and column chromatography methodologies

    International Nuclear Information System (INIS)

    Chattopadhyay, Sankha; Das, Sujata Saha; Barua, Luna

    2010-01-01

    A simple and inexpensive method has been developed for the separation of 99m Tc from 99 Mo produced from the neutron activation of 98 Mo by 98 Mo(n,γ) 99 Mo nuclear reaction. The recovery of 99m Tc was performed by solid-liquid extraction based on alumina column chromatography. The overall radiochemical yield for the complete separation of 99m Tc was 85-97% (n=5). The separated Na[ 99m Tc]TcO 4 was of high radionuclidic, radiochemical and chemical purities. The method can be adopted for routine processing and use of 99m Tc in radiopharmacy operations.

  2. Dosages d'hydrocarbures dans l'eau et le sédiment marins par infrarouge et chromatographie gazeuse sur colonne capillaire Hydrocarbon Titration in Water and Marine Sediments by Infrared Analysis and Gas Chromatography in a Capillary Column

    Directory of Open Access Journals (Sweden)

    Morel G.

    2006-11-01

    Full Text Available Nous avons étudié l'évolution des hydrocarbures pétroliers dans un site confiné, celui de l'Aber-Benoît (Finistère, à la suite de l'accident du super-pétrolier Amoco-Cadiz en mars 1978. Pour ce faire, plusieurs méthodes ont été mises en oeuvre, et tout particulièrement la chromato-graphie gazeuse sur colonne capillaire : le protocole analytique est décrit pour l'eau et pour le sédiment, après optimisation des techniques de filtration, de préconcentration et de fractionnement préalables à la mesure. Il est possible de travailler sur des échantillons de deux litres d'eau de mer ou de cinquante grammes de sédiment, avec des seuils de détection du niveau de la partie par trillion (ppt dans l'eau et de la centaine de ppt dans le sédiment. The evolution of petroleum hydrocarbons was analyzed in a confined site, at Aber-Benoît in the Finistère department, following the accident of the supertanker Amoco Cadiz in March 1978. To do this, several methods were developed, including, in particular, capillary coulumn as chromatography. The analytical procedure is described for water and sediment after optimization of filtering, preconcentrating and fractionating techniques prior to measuring. Analyses can be made with two liters of seawater or fifty grams of sediment, with detection thresholds in parts per trillion (ppt in water and the hundredth of a ppt in sediment.

  3. Quantitative analysis of twelve sulfonamides in honey after acidic hydrolysis by high-performance liquid chromatography with post-column derivatization and fluorescence detection.

    Science.gov (United States)

    Maudens, Kristof E; Zhang, Guo-Fang; Lambert, Willy E

    2004-08-20

    A quantitative HPLC-fluorescence method for the simultaneous determination of 12 sulfonamides (sulfaguanidine, sulfanilamide, sulfacetamide, sulfadiazine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamether, sulfamethazine, sulfamethoxypyridazine, sulfachloropyridazine and sulfadoxine) in honey was developed and validated. Sample pretreatment included acidic hydrolysis, followed by liquid-liquid extraction and solid-phase extraction on a strong cation exchanger. LC separation was performed in 45 min, with a total analysis time of 60 min. Identification and quantitation were based on retention time and fluorescence intensity, respectively. Peak area ratios of the target analytes and the internal standard were fit to a linear least-squares regression curve with a weighting factor of 1/x. Limits of detection and quantitation (LOQ) had values of 1 or 2 and 2 or 5 ng/g, respectively. Linearity was obtained with an average coefficient of determination (R2) higher than 0.997, over a dynamic range from the LOQ value up to 100ng/g. The method demonstrated good intra- and interbatch precision and accuracy. No interferences with the peaks of interest were observed throughout the chromatographic run. Sample pretreatment provided efficient cleanup, while post-column derivatization with fluorescamine proved to be a reproducible derivatization technique enabling a sensitive and rugged quantitative determination of sulfonamides.

  4. A simple and highly sensitive on-line column extraction liquid chromatography-tandem mass spectrometry method for the determination of protein-unbound tacrolimus in human plasma samples.

    Science.gov (United States)

    Bittersohl, Heike; Schniedewind, Björn; Christians, Uwe; Luppa, Peter B

    2018-04-27

    Therapeutic drug monitoring (TDM) of the immunosuppressive drug tacrolimus is essential to avoid side effects and rejection of the allograft after transplantation. In the blood circulation, tacrolimus is largely located inside erythrocytes or bound to plasma proteins and less than 0.1% is protein-unbound (free). One basic principle of clinical pharmacology is that only free drug is pharmacologically active and monitoring this portion has the potential to better reflect the drug effect than conventional measurements of total tacrolimus in whole blood. To address this, a highly sensitive and straightforward on-line liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed, validated and applied to patient plasma samples. The sample preparation included ultracentrifugation and addition of the stable isotope labeled drug analogue D2,13C-tacrolimus, followed by on-line sample extraction and measurement using a Sciex QTRAP ® 6500 in the multiple reaction monitoring mode. Due to very low concentrations of protein-unbound tacrolimus, it was important to develop a highly sensitive, precise and accurate assay. Here, we first report the efficient formation of tacrolimus lithium adduct ions, which greatly increased assay sensitivity. A lower limit of quantification (LLOQ) of 1 pg/mL (10 fg on column) was achieved and the assay was linear between 1 and 200 pg/mL. There was no carry-over detected. The inaccuracy ranged from -9.8 to 7.4% and the greatest imprecision was 7.5%. The matrix factor was found to be smaller than 1.1%. In summary, this method represents a suitable tool to investigate the potential clinical value of free tacrolimus monitoring in organ transplant recipients. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Automated dual two-dimensional liquid chromatography approach for fast acquisition of three-dimensional data using combinations of zwitterionic polymethacrylate and silica-based monolithic columns.

    Science.gov (United States)

    Hájek, Tomáš; Jandera, Pavel; Staňková, Magda; Česla, Petr

    2016-05-13

    A monolithic sulfobetaine polymethacrylate micro-column BIGDMA-MEDSA designed in our laboratory, shows dual retention mechanism: In acetonitrile-rich mobile phase, hydrophilic interactions control the retention (HILIC system), whereas in more aqueous mobile phases the column shows essentially reversed-phase behavior with major role of hydrophobic interactions. The zwitterionic polymethacrylate micro-column can be used in the first dimension of two-dimensional LC in alternating reversed-phase (RP) and HILIC modes, coupled with an alkyl-bonded core-shell or silica-based monolithic column in the second dimension, for HILIC×RP and RP×RP comprehensive two-dimensional separations. During the HILIC×RP period, a gradient of decreasing acetonitrile gradient is used for separation in the first dimension, so that at the end of the gradient the polymeric monolithic micro-column is equilibrated with a highly aqueous mobile phase and is ready for repeated sample injection, this time for separation under reversed-phase gradient conditions with increasing concentration of acetonitrile in the first dimension. The fast repeating reversed-phase gradients on a short silica-monolithic or core-shell column in the second dimension can be optimized independently of the actual running first-dimension gradient program. As the alternating HILIC and RP separations on the first-dimension zwitterionic methacrylate column are based on complementary retention mechanisms, the instrumental setup essentially represents two coupled two-dimensional systems. It is first time that such an automated dual LCxLC approach is reported. The novel system allows obtaining three-dimensional data in a relatively short time and can be applied not only to multidimensional gradient separations of flavones and related polyphenolic compounds. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Preparation and evaluation of open-tubular capillary column combining a metal-organic framework and a brush-shaped polymer for liquid chromatography.

    Science.gov (United States)

    Chen, Kai; Zhang, Lingyi; Zhang, Weibing

    2018-03-30

    In this work, an open-tubular capillary liquid-phase column was prepared by modifying chain polymer on the inner surface of capillary and chemical bonding of metal organic frameworks, NH 2 -UiO-66, to the brushes of chain polymer (poly(glycidyl methacrylate)). Besides advantages of facial preparation and good permeability, the chain polymer effectively increases the modification amount of NH 2 -UiO-66 nanoparticles to increase the phase ratio of open-tubular capillary column and enhance the interactions with analytes. The results of scanning electron microscope energy-dispersive X-ray spectra indicated that NH 2 -UiO-66 nanoparticles were successfully bonded to the chain polymer. Because of the hydrophobic interaction and hydrogen bonding interaction between the analytes and the ligand of NH 2 -UiO-66, different analytes were well separated on the NH 2 -UiO-66-modified poly(glycidyl methacrylate) capillary (1.12 m × 25 μm id × 365 μm od) with the high absolute column efficiency reaching 121 477 plates, benefiting from an open-tubular column and low mass transfer resistance provided by polymer brush and metal-organic framework crystal. The relative standard deviations of the retention time for run-to-run, day-to-day, and column-to-column (n = 3) runs are below 4.28%, exhibiting good repeatability. Finally, the column was successfully applied to separation of flavonoids in licorice. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Chromatography resin support

    Science.gov (United States)

    Dobos, James G.

    2002-01-01

    An apparatus and method of using an improved chromatography resin support is disclosed. The chromatography support platform is provided by a stainless steel hollow cylinder adapted for being inserted into a chromatography column. An exterior wall of the stainless steel cylinder defines a groove for carrying therein an "O"-ring. The upper surface of the stainless steel column is covered by a fine stainless steel mesh welded to the edges of the stainless steel cylinder. When placed upon a receiving ledge defined within a chromatography column, the "O"-ring provides a fluid tight seal with the inner edge wall of the chromatography cylinder. The stainless steel mesh supports the chromatography matrix and provides a back flushable support which is economical and simple to construct.

  8. Simultaneous quantification of sulfamethoxazole and trimethoprim in whole egg samples by column-switching high-performance liquid chromatography using restricted access media column for on-line sample clean-up.

    Science.gov (United States)

    de Paula, F C C R; de Pietro, A C; Cass, Q B

    2008-05-02

    This work reports the application of restricted access media (RAM) column, in a multidimensional configuration, for simultaneous analysis of sulfamethoxazole (SMX) and trimethoprim (TMP) in whole eggs with ultraviolet detection. The proteins were partially precipitated by adding 0.5 mL of acetonitrile into 1.0 mL of blended egg followed by centrifugation. The supernatant was injected (250 microL) directly into the multidimensional system. At the first dimension, a restricted access medium (RAM) bovine serum albumin (BSA) octadecyl column (100 mm x 46 mm I.D., Luna silica, 10 microm particle size and 100 A pore size), was used for extraction and concentration of the analytes and at second dimension, an octadecyl column (150 mm x 46 mm I.D., Luna silica, 10 microm particle size and 100 A pore size), for analysis. The developed method showed good selectivity, accuracy and precision for quantification of these different compounds in eggs, and the limits of quantification were 80 ng/mL, for both compounds. The validated method is reliable and sensitive for monitoring residues in whole eggs samples and thus, to determine withdraw period for laying hens using veterinary medicine having SMX-TMP combination.

  9. Towards point of care testing for C. difficile infection by volatile profiling, using the combination of a short multi-capillary gas chromatography column with metal oxide sensor detection

    International Nuclear Information System (INIS)

    McGuire, N D; Ewen, R J; De Lacy Costello, B; Garner, C E; Vaughan, K; Ratcliffe, N M; Probert, C S J

    2014-01-01

    Rapid volatile profiling of stool sample headspace was achieved using a combination of short multi-capillary chromatography column (SMCC), highly sensitive heated metal oxide semiconductor sensor and artificial neural network software. For direct analysis of biological samples this prototype offers alternatives to conventional gas chromatography (GC) detectors and electronic nose technology. The performance was compared to an identical instrument incorporating a long single capillary column (LSCC). The ability of the prototypes to separate complex mixtures was assessed using gas standards and homogenized in house ‘standard’ stool samples, with both capable of detecting more than 24 peaks per sample. The elution time was considerably faster with the SMCC resulting in a run time of 10 min compared to 30 min for the LSCC. The diagnostic potential of the prototypes was assessed using 50 C. difficile positive and 50 negative samples. The prototypes demonstrated similar capability of discriminating between positive and negative samples with sensitivity and specificity of 85% and 80% respectively. C. difficile is an important cause of hospital acquired diarrhoea, with significant morbidity and mortality around the world. A device capable of rapidly diagnosing the disease at the point of care would reduce cases, deaths and financial burden. (paper)

  10. Transfer of pharmacopoeial liquid chromatography reversedphase methods for determination of related compounds in diclofenac sodium and metamizole sodium from conventional to core-shell column

    Directory of Open Access Journals (Sweden)

    Katerina Brezovska

    2015-04-01

    Full Text Available Core-shell silica particles were developed as a new material for chromatographic stationary phases in order to provide fast and high efficiency separations of small and large molecules and complex samples, at pressures compatible with conventional HPLC equipment. The aim of our work was to show the applicability of the HPLC columns based on a core-shell technology for determination of related substances in diclofenac sodium and in metamizole sodium using the methods described in the corresponding monographs of the European pharmacopoeia. The obtained results have shown that the proposed methods can be successfully transferred on core shell column, with suitable adjustment of injection volume and flow rate. The advantage of using core-shell column is fast and highly efficient separation on conventional HPLC equipment with increased sensitivity of the method and high throughput of the analysis, providing enhanced lab productivity and reduced costs.

  11. Determination of aflatoxins and ochratoxin A in ginseng and other botanical roots by immunoaffinity column cleanup and liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Trucksess, Mary; Weaver, Carol; Oles, Carolyn; D'Ovidio, Kathleen; Rader, Jeanne

    2006-01-01

    Mycotoxins are toxic secondary metabolites produced by certain molds and are common contaminants of many important food crops, such as grains, nuts, and spices. Some mycotoxins are found in fruits, vegetables, and botanical roots. These contaminants have a broad range of toxic effects, including carcinogenicity, immunotoxicity, neurotoxicity, and reproductive and developmental toxicity. The public health concerns related to both acute and chronic effects of mycotoxins in animals have prompted more than 100 countries to establish regulatory limits for some of the well-known mycotoxins, such as the aflatoxins (AFL). Our research focused on method development for 2 of these toxins, AFL and ochratoxin A (OTA), in ginseng and other selected botanical roots. Methods using an immunoaffinity column (IAC) cleanup, liquid chromatographic separation, and fluorescence detection were modified and evaluated. Two types of IAC cleanup were evaluated: IAC for AFL, and IAC for both AFL and OTA. Three derivatization techniques to enhance the fluorescence of the AFL were compared: precolumn trifluoroacetic acid, postcolumn bromination, and postcolumn ultraviolet irradiation. No derivatization was needed for OTA. Results for AFL using the single analyte IAC cleanup and the 3 derivatization techniques were all comparable for ginseng and for other roots such as ginger, licorice, and kava-kava. Recoveries of added AFL for ginseng at levels from 2 to 16 ng/g were about 80%. Using IAC cleanup for both AFL and OTA recoveries of added AFL for ginseng at 4-16 ng/g were about 70%, and for ginger, licorice, and kava-kava were about 60%. Recoveries of added OTA for ginseng, ginger, and echinacea at 4 ng/g were about 55%.

  12. Effects of column fractions on the leaves extract of Bridelia ...

    African Journals Online (AJOL)

    The in vitro antibacterial studies were carried out on both crude extracts and fractions obtained after column chromatography against medically important bacterial strains including; Escherichia coli, Staphylococcus aureus, Micrococcus species and Pseudomonas aeruginosa for different concentrations of 30mg/ml, 60mg/ml, ...

  13. Multifunctional column coupled with liquid chromatography for determination of aflatoxins B1, B2, G1, and G2 in corn, almonds, brazil nuts, peanuts, and pistachio nuts: collaborative study.

    Science.gov (United States)

    Trucksess, M W; Stack, M E; Nesheim, S; Albert, R H; Romer, T R

    1994-01-01

    An AOAC/IUPAC collaborative study was conducted to evaluate the effectiveness of a multifunctional column for the determination of aflatoxins. The test portion is extracted with acetonitrile-water (9 + 1), the extract is filtered, and the filtrate is passed through the column. The aflatoxins in the eluate are determined by reversed-phase liquid chromatography after derivatization with trifluoroacetic acid. Naturally contaminated corn, almonds, Brazil nuts, peanuts, and pistachio nuts spiked with total aflatoxins at 5, 10, 20, and 30 ng/g were sent to 12 collaborators in the United States, Denmark, France, Japan, and Switzerland. Eleven collaborators completed the study. Average recoveries of total aflatoxins for each spike level for the various commodities (excluding Brazil nuts at 5 ng/g) were 93, 97, 95, and 95%, respectively; the repeatability relative standard deviation (RSDr) ranged from 6.0 to 23.2% and the reproducibility relative standard deviation (RSDR) ranged from 12.0 to 69.4%. The multifunctional column coupled with a liquid chromatographic method for determination of aflatoxins in corn, almonds, Brazil nuts, peanuts, and pistachio nuts has been adopted first action by AOAC INTERNATIONAL.

  14. Characterization of cis- and trans-octadecenoic acid positional isomers in edible fat and oil using gas chromatography-flame ionisation detector equipped with highly polar ionic liquid capillary column.

    Science.gov (United States)

    Yoshinaga, Kazuaki; Asanuma, Masaharu; Mizobe, Hoyo; Kojima, Koichi; Nagai, Toshiharu; Beppu, Fumiaki; Gotoh, Naohiro

    2014-10-01

    In this study, the characterisation of all cis- and trans-octadecenoic acid (C18:1) positional isomers in partially hydrogenated vegetable oil (PHVO) and milk fat, which contain several cis- and trans-C18:1 positional isomers, was achieved by gas chromatography-flame ionisation detector equipped with a highly polar ionic liquid capillary column (SLB-IL111). Prior to analysis, the cis- and trans-C18:1 fractions in PHVO and milk fat were separated using a silver-ion cartridge. The resolution of all cis-C18:1 positional isomers was successfully accomplished at the optimal isothermal column temperature of 120 °C. Similarly, the positional isomers of trans-C18:1, except for trans-6-C18:1 and trans-7-C18:1, were separated at 120 °C. The resolution of trans-6-C18:1 and trans-7-C18:1 isomers was made possible by increasing the column temperature to 160 °C. This analytical method is suitable for determining the cis- and trans-C18:1 positional isomers in edible fats and oils. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Low-level bromate analysis in drinking water by ion chromatography with optimized suppressed conductivity cell current followed by a post-column reaction and UV/Vis detection.

    Science.gov (United States)

    Fotsing, Marcellin; Barbeau, Benoit; Prevost, Michele

    2011-01-01

    In the present work, a high capacity anion exchange column was used to efficiently and simultaneously separate traces of oxyhalide disinfection byproducts (DBP) anions and bromide by an ion chromatography system followed by a post-column reaction (PCR). The PCR generates in situ hydroiodic (HI) acid from the excess of potassium iodate that combines with bromate from the column effluent to form the triiodide anion detectable by UV/Vis absorbance at 352 nm. The suppressed conductivity cell current was optimized at 70 mA, with a flow rate of 1.0 mL/min and a 9 mM carbonate eluent. Its performance was investigated on a trace-level determination of bromate in ozonated municipal and bottled drinking water. Based on ozonated municipal drinking water matrix, the method detection limit of 0.27 μg BrO(-)(3)/L was evaluated with the Method Quantification Limit (MQL) of 0.89 μg BrO(-)(3)/L. However, in ultrapure water, a MDL of 0.015 μg BrO(-)(3)/L and a MRL of 0.052 μg BrO(-)(3)/L were achieved. The recovery for spiked municipal samples was in the range of 90%-115%.

  16. Simultaneous determination of F-beta-alanine and beta-alanine in plasma and urine with dual-column reversed-phase high-performance liquid chromatography

    NARCIS (Netherlands)

    van Kuilenburg, A. B.; Stroomer, A. E.; Peters, G. J.; van Gennip, A. H.

    2001-01-01

    F-beta-Alanine and beta-alanine were detected in plasma and urine samples with fluorescence detection of orthophthaldialdehyde derivatives of F-beta-alanine and beta-alanine after separation with dual-column reversed-phase HPLC. The detection limits of F-beta-alanine and beta-alanine in the HPLC

  17. TOXICOLOGICAL ANALYSIS OF WHOLE-BLOOD SAMPLES BY MEANS OF BOND-ELUT CERTIFY COLUMNS AND GAS-CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

    NARCIS (Netherlands)

    ZWEIPFENNING, PGM; WILDERINK, AHCM; HORSTHUIS, P; FRANKE, JP; DEZEEUW, RA

    1994-01-01

    The application of Bond-Elut Certify solid-phase extraction columns to the systematic toxicological analysis of whole blood was evaluated. The reproducibility of the extraction was tested with thirteen drugs varying in physico-chemical properties. Analysis was performed with capillary gas

  18. Determination of cyclodextrins in biological fluids by high-performance liquid chromatography with negative colorimetric detection using post-column complexation with phenolphthalein

    NARCIS (Netherlands)

    Frijlink, H.W.; Visser, J.; Drenth, B.F.H.

    1987-01-01

    A rapid and sensitive high-performance liquid chromatographic method for the analysis of beta- and gamma-cyclodextrin in aqueous biological fluids such as plasma, urine, or tissue homogenate is described. The chromatographic system consists of a microBondapak Phenyl column as stationary phase and a

  19. Wall modified photonic crystal fibre capillaries as porous layer open tubular columns for in-capillary micro-extraction and capillary chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Kazarian, Artaches A. [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); W.M. Keck FT-ICR-MS Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC (United States); Sanz Rodriguez, Estrella; Deverell, Jeremy A. [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); McCord, James; Muddiman, David C. [W.M. Keck FT-ICR-MS Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC (United States); Paull, Brett, E-mail: Brett.Paull@utas.edu.au [Australian Centre for Research on Separation Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia); ARC Centre of Excellence for Electromaterials Science, School of Physical Sciences, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001 (Australia)

    2016-01-28

    Wall modified photonic crystal fibre capillary columns for in-capillary micro-extraction and liquid chromatographic separations is presented. Columns contained 126 internal parallel 4 μm channels, each containing a wall bonded porous monolithic type polystyrene-divinylbenzene layer in open tubular column format (PLOT). Modification longitudinal homogeneity was monitored using scanning contactless conductivity detection and scanning electron microscopy. The multichannel open tubular capillary column showed channel diameter and polymer layer consistency of 4.2 ± 0.1 μm and 0.26 ± 0.02 μm respectively, and modification of 100% of the parallel channels with the monolithic polymer. The modified multi-channel capillaries were applied to the in-capillary micro-extraction of water samples. 500 μL of water samples containing single μg L{sup −1} levels of polyaromatic hydrocarbons were extracted at a flow rate of 10 μL min{sup −1}, and eluted in 50 μL of acetonitrile for analysis using HPLC with fluorescence detection. HPLC LODs were 0.08, 0.02 and 0.05 μg L{sup −1} for acenaphthene, anthracene and pyrene, respectively, with extraction recoveries of between 77 and 103%. The modified capillaries were also investigated briefly for direct application to liquid chromatographic separations, with the retention and elution of a standard protein (cytochrome c) under isocratic conditions demonstrated, proving chromatographic potential of the new column format, with run-to-run retention time reproducibility of below 1%. - Highlights: • Novel PS-DVB modified photonic crystal fibres for in-capillary micro-extraction. • New method for micro-extraction of PAHs and HPLC-FL detection at sub-ppb levels. • Demonstration of PS-DVB modified photonic crystal fibres for capillary bioseparations.

  20. Highly Sensitive Determination of 2,4,6-Trinitrotoluene and Related Byproducts Using a Diol Functionalized Column for High Performance Liquid Chromatography

    NARCIS (Netherlands)

    Gümüscü, B.; Erdogan, Zeynep; Guler, Mustafa O.; Tekinay, Turgay

    2016-01-01

    In this work, a new detection method for complete separation of 2,4,6-trinitrotoluene (TNT); 2,4-dinitrotoluene (2,4-DNT); 2,6-dinitrotoluene (2,6-DNT); 2-aminodinitrotoluene (2-ADNT) and 4-aminodinitrotoluene (4-ADNT) molecules in high-performance liquid-chromatography (HPLC) with UV sensor has

  1. Reliability of simulated robustness testing in fast liquid chromatography, using state-of-the-art column technology, instrumentation and modelling software.

    Science.gov (United States)

    Kormány, Róbert; Fekete, Jenő; Guillarme, Davy; Fekete, Szabolcs

    2014-02-01

    The goal of this study was to evaluate the accuracy of simulated robustness testing using commercial modelling software (DryLab) and state-of-the-art stationary phases. For this purpose, a mixture of amlodipine and its seven related impurities was analyzed on short narrow bore columns (50×2.1mm, packed with sub-2μm particles) providing short analysis times. The performance of commercial modelling software for robustness testing was systematically compared to experimental measurements and DoE based predictions. We have demonstrated that the reliability of predictions was good, since the predicted retention times and resolutions were in good agreement with the experimental ones at the edges of the design space. In average, the retention time relative errors were software, we proved that the separation was feasible on all columns within the same analysis time (less than 4min), by proper adjustments of variables. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. High-performance liquid chromatography analysis of polyacetylenes and polyenes in Echinacea pallida by using a monolithic reversed-phase silica column.

    Science.gov (United States)

    Pellati, Federica; Calò, Samuele; Benvenuti, Stefania

    2007-05-11

    In this study, a RP-HPLC method for the analysis of polyacetylenes and polyenes in Echinacea pallida roots and phytopharmaceuticals was developed. The reference compounds used for quantification were isolated from the plant material and their structures were determined on the basis of the analysis of UV, IR, NMR and MS data. The complete structure elucidation of three compounds, namely 8-hydroxy-tetradec-(9E)-ene-11,13-diyn-2-one (1), tetradec-(8Z)-ene-11,13-diyn-2-one (6) and pentadec-(8Z)-en-2-one (9) is described. In the analysis of the n-hexane extracts of E. pallida roots, the comparison between conventional and monolithic columns showed that the elution order in both cases is identical and the selectivity is equivalent. However, the retention times achieved by the monolithic column are shorter, resulting in a faster separation (20 min). Therefore, the analyses were carried out on a Chromolith Performance RP-18e (100 mm x 4.6 mm i.d.), with a gradient mobile phase composed by H(2)O and ACN at the flow rate of 2 mL/min. The column was thermostatted at 20 degrees C. The photodiode array detector monitored the eluent at 210 nm. The validation procedure confirmed that this technique affords reliable analysis of these components and is appropriate for the quality control of complex matrices, such as E. pallida roots and phytopharmaceuticals.

  3. Development and characterization of a novel plug and play liquid chromatography-mass spectrometry (LC-MS) source that automates connections between the capillary trap, column, and emitter.

    Science.gov (United States)

    Bereman, Michael S; Hsieh, Edward J; Corso, Thomas N; Van Pelt, Colleen K; Maccoss, Michael J

    2013-06-01

    We report the development and characterization of a novel, vendor-neutral ultra-high pressure-compatible (~10,000 p.s.i.) LC-MS source. This device is the first to make automated connections with user-packed capillary traps, columns, and capillary emitters. The source uses plastic rectangular inserts (referred to here as cartridges) where individual components (i.e. trap, column, or emitter) can be exchanged independent of one another in a plug and play manner. Automated robotic connections are made between the three cartridges using linear translation powered by stepper motors to axially compress each cartridge by applying a well controlled constant compression force to each commercial LC fitting. The user has the versatility to tailor the separation (e.g. the length of the column, type of stationary phase, and mode of separation) to the experimental design of interest in a cost-effective manner. The source is described in detail, and several experiments are performed to evaluate the robustness of both the system and the exchange of the individual trap and emitter cartridges. The standard deviation in the retention time of four targeted peptides from a standard digest interlaced with a soluble Caenorhabditis elegans lysate ranged between 3.1 and 5.3 s over 3 days of analyses. Exchange of the emitter cartridge was found to have an insignificant effect on the abundance of various peptides. In addition, the trap cartridge can be replaced with minimal effects on retention time (<20 s).

  4. A novel application of Onyxtrade mark monolithic column for simultaneous determination of salicylic acid and triamcinolone acetonide by sequential injection chromatography.

    Science.gov (United States)

    Chocholous, Petr; Holík, Pavel; Satínský, Dalibor; Solich, Petr

    2007-04-30

    A novel and fast simultaneous determination of triamcinolone acetonide (TCA) and salicylic acid (SA) in topical pharmaceutical formulations by sequential injection chromatography (SIC) as an alternative to classical high performance liquid chromatography (HPLC) has been developed. A recently introduced Onyxtrade mark monolithic C18 (50mmx4.6mm, Phenomenex((R))) with 5mm monolithic precolumn were used for the first time for creating sequential injection chromatography system based on a FIAlab((R)) 3000 with a six-port selection valve and 5.0mL syringe pump in study. The mobile phase used was acetonitrile/water (35:65, v/v), pH 3.3 adjusted with acetic acid at flow rate 0.9mLmin(-1). UV detection provided by fibre-optic DAD detector was set up at 240nm. Propylparaben was chosen as suitable internal standard (IS). There is only simple pre-adjustment of the sample of topical solution (dilution with mobile phase) so the analysis is not uselessly elongated. Parameters of the method showed good linearity in wide range, correlation coefficient >0.999; system precision (relative standard deviation, R.S.D.) in the range 0.45-1.95% at three different concentration levels, detection limits (3sigma) 1.00mugmL(-1) (salicylic acid), 0.66mugmL(-1) (triamcinolone acetonide) and 0.33mugmL(-1) (propylparaben) and recovery from the pharmaceutical preparations in the range 97.50-98.94%. The chromatographic resolution between peaks of compounds was more than 4.5 and analysis time was 5.1min under the optimal conditions. The advantages of sequential injection chromatography against classical HPLC are discussed and showing that SIC can be a method of option in many cases.

  5. Monolithic and core-shell columns in comprehensive two-dimensional HPLC: a review.

    Science.gov (United States)

    Jandera, Pavel; Hájek, Tomáš; Staňková, Magda

    2015-01-01

    The crucial point affecting the separation time in comprehensive two-dimensional liquid chromatography is the performance of the column used in the second dimension, which should allow highly efficient fast chromatographic separations in the short time available for the analysis of fractions transferred from the first to the second dimension (often 1 min or less). This can be accomplished on short columns packed with sub-2-μm particles, at the cost of very high operation pressure. Core-shell or silica monolithic columns have better permeability, and their use in the second dimension of comprehensive two-dimensional liquid chromatography with conventional liquid chromatography instrumentation is continuously increasing. Monolithic columns based on organic polymer matrices offer a wide selection of stationary phase chemistries, including new hydrophilic interaction liquid chromatography materials, which can be used in the design of novel two-dimensional separations. Some organic polymer monolithic materials offer a dual retention mechanism (reversed-phase hydrophilic interaction liquid chromatography), so a single column can be used in alternating runs for highly orthogonal off-line two-dimensional and even three-dimensional separations. In the present work, the properties of core-shell and silica gel monolithic columns are briefly summarized and their applications in two-dimensional separations of peptides, proteins, oligomer surfactants, fats and oils, carotenoids, phenolic and flavone compounds in plant extracts, food, and beverages are reviewed.

  6. Determination of acrolein in serum by high-performance liquid chromatography with fluorescence detection after pre-column fluorogenic derivatization using 1,2-diamino-4,5-dimethoxybenzene.

    Science.gov (United States)

    Imazato, Takahiro; Kanematsu, Mariko; Kishikawa, Naoya; Ohyama, Kaname; Hino, Takako; Ueki, Yukitaka; Maehata, Eisuke; Kuroda, Naotaka

    2015-09-01

    Acrolein is a major unsaturated aldehyde that is generated during the lipid peroxidation process. The measurement of acrolein in biological samples should be useful to estimate the degree of lipid peroxidation and to evaluate the effect of hazardous properties of acrolein on human health. In this study, a highly sensitive and selective high-performance liquid chromatography with fluorescence detection method was developed for the determination of acrolein in human serum. The proposed method involves the pre-column fluorogenic derivatization of acrolein with 1,2-diamino-4,5-dimethoxybenzene (DDB) as a reagent. The fluorescent derivative of acrolein could be detected clearly without any interfering reagent blank peaks because DDB does not have intrinsic fluorescence itself, and the detection limit was 10 nM (signal-to-noise ratio = 3). The proposed method could selectively detect acrolein in human serum with a simple protein precipitation treatment. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Simultaneous determination of 13 carotenoids by a simple C18 column-based ultra-high-pressure liquid chromatography method for carotenoid profiling in the astaxanthin-accumulating Haematococcus pluvialis.

    Science.gov (United States)

    Jin, Hui; Lao, Yong Min; Zhou, Jin; Zhang, Huai Jin; Cai, Zhong Hua

    2017-03-10

    A simple ultra-high-pressure liquid chromatography (UHPLC) method for rapidly and simultaneously identifying thirteen carotenoids in Haematococcus pluvialis was developed in this study. The method is capable of effectively separating two astaxanthin isomers, two ζ-carotene isomers, and three phytoene isomers on two simple C18 columns within 9 and 12min only by using methanol and acetonitrile, respectively. To our best knowledge, this is the rapidest method for these carotenoid isomers, currently. Using this method, carotenoid profiling in the astaxanthin-accumulating H. pluvialis under environmental stresses was successfully carried out. Results indicated that carotenoid biosynthesis was differentially perturbed by environmental stresses, indicating that this simple and rapid method is suitable to not only bacterial but also algal samples, with potential applications for a wide range of samples from plant to animal. Finally, possible reasons for the elution order of carotenoids were studied. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Utilizing immunoaffinity chromatography (IAC) cross-reactivity in GC-MS/MS exemplified at the measurement of prostaglandin E1 in human plasma using prostaglandin E2-specific IAC columns.

    Science.gov (United States)

    Tsikas, Dimitrios; Suchy, Maria-Theresia; Tödter, Klaus; Heeren, Joerg; Scheja, Ludger

    2016-05-15

    Immunoaffinity chromatography (IAC) is an elegant and highly efficient method to isolate a particular compound from biological samples for measurement by mass spectrometry coupled to GC, CE, or LC. The utility of IAC for the quantitative determination of several prostaglandins including prostaglandin E2 (PGE2) by GC-MS/MS and LC-MS/MS has been demonstrated. The aim of the present work was to test whether the cross-reactivity of the antibody immobilized on an insoluble support can be utilized for the quantitative determination of biomolecules by stable-isotope dilution mass spectrometry. In this communication, we provide evidence that this is indeed possible for prostaglandin E1 (PGE1) in human plasma by GC-MS/MS using commercially available Sepharose 4-based IAC columns with immobilized mouse anti-PGE2 monoclonal antibody with a declared cross-reactivity of about 19% toward PGE1. Endogenous PGE1 and the internal standard [3,3',4,4'-(2)H4]-PGE1 (d4-PGE1) externally added to human plasma samples were extracted by IAC, converted to their pentafluorobenzyl ester-methoxime-trimethylsilyl ether derivatives and analyzed by GC-MS/MS in the electron-capture negative-ion chemical ionization mode. Quantification was performed by selected-reaction monitoring of the mass transition m/z 526→m/z 258 for PGE1 and m/z 530→m/z 262 for d4-PGE1. By this method we measured PGE1 concentrations in EDTA plasma samples (1mL) of six healthy volunteers in the range 10-25pg/mL (29-72pM). PGE1 plasma concentration showed a trend for positive correlation with plasma parameters such as low density lipoprotein (LDL)-cholesterol, total cholesterol and glucose. The method described here provides a novel tool to study the potential link of PGE1 formation to dyslipidemia, insulin resistance and related metabolic disorders. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Characterisation of acid dyes in forensic fibre analysis by high-performance liquid chromatography using narrow-bore columns and diode array detection.

    Science.gov (United States)

    Laing, D K; Gill, R; Blacklaws, C; Bickley, H M

    1988-06-17

    A gradient elution high-performance liquid chromatographic (HPLC) system with a diode array detector and a short narrow-bore (40 x 1 mm I.D.) column has been used to characterise a number of acid dyes. The resolution and reproducibility of the HPLC system have been evaluated and the detection limits for various dyes have been estimated. Comparisons are made with current methods of fibre dyestuff examination used in forensic science. The system has been applied to the analysis of dye extracted from single fibres. Using diode array detection, both chromatographic and spectral data can be produced in a single operation from casework sized samples.

  10. Applications of a post-column fluorigenic reaction in liquid chromatography for the determination of glucose and fructose in biological matrices

    International Nuclear Information System (INIS)

    Coquet, A.; Veuthey, J.-L.; Haerdi, W.; Degli Agosti, R.

    1991-01-01

    A post-column fluorigenic reaction with benzamidine coupled to liquid chromatographic separation was used for the determination of reducing carbohydrates in three complex biological samples. This method allows the simultaneous determination of the different reducing sugars, which represent an improvement over batch enzymatic tests where in most instances only single monosaccharides can be determined. This selective liquid chromatographic method has a broad linear range. The method was validated by simultaneous analyses with a specific enzymatic test for glucose. Results are presented for the determination of glucose in human serum and mustard plants and glucose and fructose in white wines. (author). 14 refs.; 3 figs.; 3 tabs

  11. Liquid Chromatography with Post-Column Reagent Addition of Ammonia in Methanol Coupled to Negative Ion Electrospray Ionization Tandem Mass Spectrometry for Determination of Phenoxyacid Herbicides and their Degradation Products in Surface Water

    Directory of Open Access Journals (Sweden)

    Michele L. Etter

    2010-02-01

    Full Text Available A new liquid chromatography (LC-negative ion electrospray ionization (ESI–tandem mass spectrometry (MS/MS method with post-column addition of ammonia in methanol has been developed for the analysis of acid herbicides: 2,4-dichlorophenoxy ace- tic acid, 4-chloro-o-tolyloxyacetic acid, 2-(2-methyl-4-chlorophenoxybutyric acid, mecoprop, dichlorprop, 4-(2,4-dichlorophenoxy butyric acid, 2,4,5-trichlorophenoxy propionic acid, dicamba and bromoxynil, along with their degradation products: 4-chloro-2- methylphenol, 2,4-dichlorophenol, 2,4,5-trichlorophenol and 3,5-dibromo-4-hydroxybenzoic acid. The samples were extracted from the surface water matrix using solid-phase extraction (SPE with a polymeric sorbent and analyzed with LC ESI- with selected reaction monitoring (SRM using a three-point confirmation approach. Chromatography was performed on a Zorbax Eclipse XDB-C18 (50 × 4.6 mm i.d., 1.8 µm with a gradient elution using water-methanol with 2 mM ammonium acetate mobile phase at a flow rate of 0.15 mL/min. Ammonia in methanol (0.8 M was added post-column at a flow rate of 0.05 mL/min to enhance ionization of the deg- radation products in the MS source. One SRM transition was used for quantitative analysis while the second SRM along with the ratio of SRM1/SRM2 within the relative standard deviation determined by standards for each individual pesticide and retention time match were used for confirmation. The standard deviation of ratio of SRM1/SRM2 obtained from standards run on the day of analysis for different phenoxyacid herbicides ranged from 3.9 to 18.5%. Limits of detection (LOD were between 1 and 15 ng L-1 and method detection limits (MDL with strict criteria requiring

  12. Development and validation of a high-performance liquid chromatography method for determination of ractopamine residue in pork samples by solid phase extraction and pre-column derivatization.

    Science.gov (United States)

    Ding, Guanglong; Li, Deguang; Qin, Jiao; Zhu, Juanli; Wang, Baitao; Geng, Qianqian; Guo, Mingcheng; Punyapitak, Darunee; Cao, Yongsong

    2015-08-01

    Ractopamine (RAC) has been approved as a feed additive for swine, cattle or turkey, and is likely to have residue in edible animal products and may pose a potential risk for consumer health. Therefore, it is essential to establish a method to detect the residue of RAC in animal products. This work presents a rapid and sensitive HPLC method for the determination of RAC in pork samples with pre-column derivatization. The RAC derivative was separated on a kromasil C18 column and detected at 284nm with a UV detector. The detection capability (CCβ) was 0.078μgg(-1) and the linearity was established over the concentration range of 0.15-100.0μgg(-1). The overall mean recovery in spike range of 0.2μgg(-1) to 100μgg(-1) was 89.9% with the overall mean relative standard deviation of 4.1%. This method can be used for the quantification of RAC in pork samples and help to establish adequate monitoring of the residue of RAC. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Selective determination of quinones by high-performance liquid chromatography with on-line post column ultraviolet irradiation and peroxyoxalate chemiluminescence detection.

    Science.gov (United States)

    Ahmed, Sameh; Fujii, Shuu; Kishikawa, Naoya; Ohba, Yoshihito; Nakashima, Kenichiro; Kuroda, Naotaka

    2006-11-10

    A new HPLC method was developed for the simultaneous determination of quinones with peroxyoxalate chemiluminescence (PO-CL) detection following on-line UV irradiation. Quinones [i.e., 1,2-naphthoquinone, 1,4-naphthoquinone, 9,10-anthraquinone, 9,10-phenanthrenequinone] were UV irradiated (254 nm, 15 W) to generate hydrogen peroxide and a fluorescent product that were determined via PO-CL detection. Generation of hydrogen peroxide from quinones with on-line UV irradiation was confirmed using flow injection analysis (FIA) system whereby incorporating an enzyme column reactor immobilized with catalase. Moreover, the structure of the produced fluorophore was confirmed using LC-MS, IR, and (1)H NMR. Afterwards, the conditions for UV irradiation and PO-CL detection were optimized. The separation of four quinones by HPLC was accomplished isocratically on an ODS column within 25 min. The detection limits (signal-to-noise ratio=3) were 6.0 pmol/injection for 1,2-naphthoquinone, 4.4 pmol/injection for 1,4-naphthoquinone, 0.2 pmol/injection for 9,10-anthraquinone, and 0.45 pmol/injection for 9,10-phenanthrenequinone.

  14. Plasma chromatography

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    This book examines the fundamental theory and various applications of ion mobility spectroscopy. Plasma chromatography developed from research on the diffusion and mobility of ions. Topics considered include instrument design and description (e.g., performance, spectral interpretation, sample handling, mass spectrometry), the role of ion mobility in plasma chromatography (e.g., kinetic theory of ion transport), atmospheric pressure ionization (e.g., rate equations), the characterization of isomers by plasma chromatography (e.g., molecular ion characteristics, polynuclear aromatics), plasma chromatography as a gas chromatographic detection method (e.g., qualitative analysis, continuous mobility monitoring, quantitative analysis), the analysis of toxic vapors by plasma chromatography (e.g., plasma chromatograph calibration, instrument control and data processing), the analysis of semiconductor devices and microelectronic packages by plasma chromatography/mass spectroscopy (e.g., analysis of organic surface contaminants, analysis of water in sealed electronic packages), and instrument design and automation (hardware, software)

  15. A fast and accurate method for the pharmacokinetic research of four coumarin analogs in Fructus cnidii using capillary electro-chromatography with a methacrylate ester-based monolithic column.

    Science.gov (United States)

    Chen, Zhao; Xu, Aili; Bi, Xiaoli; Luo, Wenhui; Li, Ji; Fan, Guorong; Sun, Dongmei

    2017-11-01

    In the present study, a monolithic capillary column with higher permeability was developed for the in vivo discrimination of four coumarin analogs (bergapten, 2'-acetylangelicin, imperatorin, and osthole) that typically require long separation times in HPLC. Instead of conventional methacrylate ester monolith (containing 19.5% porogen) with insufficient permeability (K = 1.52 - 1.66 × 10 -14 M 2 ) for plasma sample, the proposed column (20.5% porogen) had better permeability (around 3.80 × 10 -14 M 2 ) while properties such as pore distribution, stability, and resolution changed slightly. As a result, due to the negatively charged electro-dynamic flow of the methacrylate ester groups in the monolith, the migration of targeted analytes was achieved within 6 min (compared with 30 min in HPLC) with acceptable resolution and improved sensitivity (0.005-0.02 μg/mL vs. 0.04 μg/mL). The proposed method was also applied to pharmacokinetic research: accelerated solvent extraction (ASE) was used to improve the extraction efficiency, which prepared extract much faster and more pure than conventional methods. As the pharmacokinetic parameters indicated, the monolithic capillary electro-chromatography method was efficient, sensitive, specific, and durable, guaranteeing its utility for the determination of multiple structure-related compounds in rat plasma. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Liquid chromatography coupled to different atmospheric pressure ionization sources-quadrupole-time-of-flight mass spectrometry and post-column addition of metal salt solutions as a powerful tool for the metabolic profiling of Fusarium oxysporum.

    Science.gov (United States)

    Cirigliano, Adriana M; Rodriguez, M Alejandra; Gagliano, M Laura; Bertinetti, Brenda V; Godeas, Alicia M; Cabrera, Gabriela M

    2016-03-25

    Fusarium oxysporum L11 is a non-pathogenic soil-borne fungal strain that yielded an extract that showed antifungal activity against phytopathogens. In this study, reversed-phase high-performance liquid chromatography (RP-HPLC) coupled to different atmospheric pressure ionization sources-quadrupole-time-of-flight mass spectrometry (API-QTOF-MS) was applied for the comprehensive profiling of the metabolites from the extract. The employed sources were electrospray (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). Post-column addition of metal solutions of Ca, Cu and Zn(II) was also tested using ESI. A total of 137 compounds were identified or tentatively identified by matching their accurate mass signals, suggested molecular formulae and MS/MS analysis with previously reported data. Some compounds were isolated and identified by NMR. The extract was rich in cyclic peptides like cyclosporins, diketopiperazines and sansalvamides, most of which were new, and are reported here for the first time. The use of post-column addition of metals resulted in a useful strategy for the discrimination of compound classes since specific adducts were observed for the different compound families. This technique also allowed the screening for compounds with metal binding properties. Thus, the applied methodology is a useful choice for the metabolic profiling of extracts and also for the selection of metabolites with potential biological activities related to interactions with metal ions. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Ultra-fast liquid chromatography with tandem mass spectrometry determination of ochratoxin A in traditional Chinese medicines based on vortex-assisted solid-liquid microextraction and aptamer-affinity column clean-up.

    Science.gov (United States)

    Yang, Xihui; Hu, Yichen; Kong, Weijun; Chu, Xianfeng; Yang, Meihua; Zhao, Ming; Ouyang, Zhen

    2014-11-01

    A rapid, selective, and sensitive ultra-fast liquid chromatography with tandem mass spectrometry method was developed for the determination of ochratoxin A in traditional Chinese medicines based on vortex-assisted solid-liquid microextraction and aptamer-affinity column clean-up. Through optimizing the sample pretreatment procedures and chromatographic conditions, good linearity (r(2) ≥ 0.9993), low limit of detection (0.5-0.8 μg/kg), and satisfactory recovery (83.54-94.44%) expressed the good reliability and applicability of the established method in various traditional Chinese medicines. Moreover, the aptamer-affinity column, prepared in-house, showed an excellent feasibility owing to its specific identification of ochratoxin A in various kinds of selected traditional Chinese medicines. The maximum adsorption amount and applicability value were 188.96 ± 10.56 ng and 72.3%, respectively. The matrix effects were effectively eliminated, especially for m/z 404.2→358.0 of ochratoxin A. The application of the developed method for screening the natural contamination levels of ochratoxin A in 25 random traditional Chinese medicines on the market in China indicated that only eight samples were contaminated with low levels below the legal limit (5.0 μg/kg) set by the European Union. This study provided a preferred choice for the rapid and accurate monitoring of ochratoxin A in complex matrices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. On the use of ionic liquid capillary columns for analysis of aromatic hydrocarbons in low-boiling petrochemical products by one-dimensional and comprehensive two-dimensional gas chromatography.

    Science.gov (United States)

    Krupčík, Ján; Gorovenko, Roman; Špánik, Ivan; Bočková, Ingrid; Sandra, Pat; Armstrong, Daniel W

    2013-08-02

    One-dimensional and comprehensive two-dimensional flow modulated gas chromatography with simultaneous flame ionization and mass spectrometric detection were applied for the identification and quantification of benzene, toluene, ethyl benzene and xylenes (BTEX) as well as of all C9-C11 aromatic hydrocarbons in the low-boiling petroleum products gasoline, reformate and fluid catalytic cracking (FCC) samples. GC×GC experiments were performed on two reversed phase polarity column sets namely SLB-IL100 (25m×250μm i.d.×0.2μm df)+HP-5MS (5m×250μm i.d.×0.25μm df) and SLB-IL111 (30m×250μm i.d.×0.2μm df)+HP-5MS (5m×250μm i.d.×0.25μm df). The one-dimensional GC experiments were carried out on the same ionic liquid columns. The most powerful method is GC×GC on the SLB-111+HP-5MS column combination. Quantitative analysis of individual aromatic hydrocarbons (C6-C11) present in gasoline, reformate and fluid catalytic cracking (FCC) samples was performed by GC×GC-FID using the internal normalization method. Mass spectra obtained by GC×GC-qMSD were used for identification of the aromatic hydrocarbons in these samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Analysis of Listeria using exogenous volatile organic compound metabolites and their detection by static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS).

    Science.gov (United States)

    Taylor, Carl; Lough, Fraser; Stanforth, Stephen P; Schwalbe, Edward C; Fowlis, Ian A; Dean, John R

    2017-07-01

    Listeria monocytogenes is a Gram-positive bacterium and an opportunistic food-borne pathogen which poses significant risk to the immune-compromised and pregnant due to the increased likelihood of acquiring infection and potential transmission of infection to the unborn child. Conventional methods of analysis suffer from either long turn-around times or lack the ability to discriminate between Listeria spp. reliably. This paper investigates an alternative method of detecting Listeria spp. using two novel enzyme substrates that liberate exogenous volatile organic compounds in the presence of α-mannosidase and D-alanyl aminopeptidase. The discriminating capabilities of this approach for identifying L. monocytogenes from other species of Listeria are investigated. The liberated volatile organic compounds (VOCs) are detected using an automated analytical technique based on static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS). The results obtained by SHS-MCC-GC-IMS are compared with those obtained by the more conventional analytical technique of headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS). The results found that it was possible to differentiate between L. monocytogenes and L. ivanovii, based on their VOC response from α-mannosidase activity.

  20. Determination of 9, 10-phenanthrenequinone in airborne particulates by High-Performance Liquid Chromatography with post-column fluorescence derivatization using 2-aminothiophenol.

    Science.gov (United States)

    Kishikawa, Naoya; Nakashima, Hajime; Ohyama, Kaname; Nakashima, Kenichiro; Kuroda, Naotaka

    2010-06-15

    9, 10-Phenanthrenequinone (PQ) is regarded as a harmful environmental pollutant and its presence has been reported in atmospheric environment. The measurement of PQ in environment should be necessary to evaluate the influence of PQ on human health. We found that PQ reacted with 2-aminothiophenol under acidic condition to form fluorescent derivative which emits green fluorescence at 510nm. Based on this reaction, a simple and rapid determination method for PQ was developed by HPLC with post-column derivatization and fluorescence detection. By the proposed HPLC system, PQ was detected at 24min and the detection limit was 67fmol/injection (S/N=3). The proposed method was able to determine the atmospheric PQ concentrations by the direct injection of extract from airborne particulates.

  1. Improved separation and quantification of dioxin and furan congeners using novel low-bleed capillary gas chromatography columns and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dorman, F. [Restek Corporation, Bellefonte, PA (United States); Reese, S. [Folsom Lake College, Folsom, CA (United States); Reiner, E.; MacPherson, K. [Ontario Ministry of the Environment, Ottawa, Ontario (Canada); Focant, J. [Liege Univ. (Belgium); Cochran, J. [LECO Corporation, St. Josephs, MI (United States)

    2004-09-15

    This presentation will address the development of two new stationary phase chemistries that allow for improved separation of the toxic dioxin and furan congeners. Using conventional high-resolution mass spectrometry, it is possible to separate all of the congeners of interest in a single analysis on one column. Quantitation values from standard reference materials, fly ash, and previously characterized samples will be shown as evidence of how this separation is faster and more accurate than has previously been available. Finally results from comprehensive two-dimensional GC coupled to time-of-flight MS will be shown to demonstrate how this technique can rival the high-resolution method in terms of quality of information.

  2. Small Column Ion Exchange

    International Nuclear Information System (INIS)

    Huff, Thomas

    2010-01-01

    Small Column Ion Exchange (SCIX) leverages a suite of technologies developed by DOE across the complex to achieve lifecycle savings. Technologies are applicable to multiple sites. Early testing supported multiple sites. Balance of SRS SCIX testing supports SRS deployment. A forma Systems Engineering Evaluation (SEE) was performed and selected Small Column Ion Exchange columns containing Crystalline Silicotitanate (CST) in a 2-column lead/lag configuration. SEE considered use of Spherical Resorcinol-Formaldehyde (sRF). Advantages of approach at SRS include: (1) no new buildings, (2) low volume of Cs waste in solid form compared to aqueous strip effluent; and availability of downstream processing facilities for immediate processing of spent resin.

  3. Thin-layer and paper chromatography

    International Nuclear Information System (INIS)

    Sherma, J.

    1986-01-01

    This selective review covers the literature of thin-layer chromatography (TLC) and paper chromatography (PC) cited in Chemical Abstracts from December 5, 1983, through November 25, 1985, and Analytical Abstracts from November 1983 to November 1985. Also researched directly were the following important journals publishing papers on TLC and PC: the Journal of Chromatography (including its bibliography issues), Journal of High Resolution Chromatography and Chromatography Communications, Journal of Chromatographic Science, Chromatographia, Analytical Chemistry, JAOAC, and the special TLC issues of the Journal of Liquid Chromatography. Many of the inherent advantages of TLC that are obvious to workers familiar with high performance, quantitative theory and practice still are not appreciated adequately by the majority of people using chromatography. These include unrestricted access to the separation process; introducing magnetic, thermal, electrical, and other physical forces to improve resolution; high sample throughput; truly multidimensional separations; and the use of controlled multiple gradients. Many advantages of TLC relative to column chromatography were discussed in the Introductions to our 1982 and 1984 reviews of TLC in this Journal. No complete commercial robotics system specifically for TLC has been developed, but all necessary modules are available for such a system. The combination of robotics, with the continued development of theory, practice, and instrumentation will lead eventually to TLC systems that are unrivaled for speed, versatility, accuracy, precision, and sensitivity. 573 references

  4. Charge heterogeneity profiling of monoclonal antibodies using low ionic strength ion-exchange chromatography and well-controlled pH gradients on monolithic columns.

    Science.gov (United States)

    Talebi, Mohammad; Nordborg, Anna; Gaspar, Andras; Lacher, Nathan A; Wang, Qian; He, Xiaoping Z; Haddad, Paul R; Hilder, Emily F

    2013-11-22

    In this work, the suitability of employing shallow pH gradients generated using single component buffer systems as eluents through cation-exchange (CEX) monolithic columns is demonstrated for the high-resolution separation of monoclonal antibody (mAb) charge variants in three different biopharmaceuticals. A useful selection of small molecule buffer species is described that can be used within very narrow pH ranges (typically 1 pH unit) defined by their buffer capacity for producing controlled and smooth pH profiles when used together with porous polymer monoliths. Using very low ionic strength eluents also enabled direct coupling with electrospray ionisation mass spectrometry. The results obtained by the developed pH gradient approach for the separation of closely related antibody species appear to be consistent with those obtained by imaged capillary isoelectric focusing (iCE) in terms of both resolution and separation profile. Both determinants of resolution, i.e., peak compression and peak separation contribute to the gains in resolution, evidently through the Donnan potential effect, which is increased by decreasing the eluent concentration, and also through the way electrostatic charges are distributed on the protein surface. Retention mechanisms based on the trends observed in retention of proteins at pH values higher than the electrophoretic pI are also discussed using applicable theories. Employing monolithic ion-exchangers is shown to enable fast method development, short analysis time, and high sample throughput owing to the accelerated mass transport of the monolithic media. The possibility of short analysis time, typically less than 15 min, and high sample throughput is extremely useful in the assessment of charge-based changes to the mAb products, such as during manufacturing or storage. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Multiresidue pesticide analysis of botanical dietary supplements using salt-out acetonitrile extraction, solid-phase extraction cleanup column, and gas chromatography-triple quadrupole mass spectrometry.

    Science.gov (United States)

    Hayward, Douglas G; Wong, Jon W; Shi, Feng; Zhang, Kai; Lee, Nathaniel S; DiBenedetto, Alex L; Hengel, Mathew J

    2013-05-07

    Dietary supplements form an increasing part of the American diet, yet broadly applicable multiresidue pesticide methods have not been evaluated for many of these supplements. A method for the analysis of 310 pesticides, isomers, and pesticide metabolites in dried botanical dietary supplements has been developed and validated. Sample preparation involved acetonitrile:water added to the botanical along with anhydrous magnesium sulfate and sodium chloride for extraction, followed by cleanup with solid-phase extraction using a tandem cartridge consisting of graphitized carbon black (GCB) and primary-secondary amine sorbent (PSA). Pesticides were measured by gas chromatography-tandem mass spectrometry. Accuracy and precision were evaluated through fortifications of 24 botanicals at 10, 25, 100, and 500 μg/kg. Mean pesticide recoveries and relative standard deviations (RSDs) for all botanicals were 97%, 91%, 90%, and 90% and 15%, 10%, 8%, and 6% at 10, 25, 100, and 500 μg/kg, respectively. The method was applied to 21 incurred botanicals. Quinoxyfen was measured in hops (100-620 μg/kg). Tetraconazole (48 μg/kg), tetramethrin (15 μg/kg), methamidophos (50 μg/kg), and chlorpyrifos (93 μg/kg) were measured in licorice, mallow, tea, and tribulus, respectively. Quintozene, its metabolites and contaminants (pentachloroaniline, pentachlorobenzene, pentachloroanisole, and pentachlorothioanisole and hexachlorobenzene and tecnazene, respectively), with hexachlorocyclohexanes and DDT were identified in ginseng sources along with azoxystrobin, diazinon, and dimethomorph between 0.7 and 2800 μg/kg. Validation with these botanicals demonstrated the extent of this method's applicability for screening 310 pesticides in a wide array of botanical dietary supplements.

  6. Impact of the limitations of state-of-the-art micro-fabrication processes on the performance of pillar array columns for liquid chromatography.

    Science.gov (United States)

    Op de Beeck, Jeff; De Malsche, Wim; Tezcan, Deniz S; De Moor, Piet; Desmet, Gert

    2012-05-25

    We report on the practical limitations of the current state-of-the-art in micro-fabrication technology to produce the small pillar sizes that are needed to obtain high efficiency pillar array columns. For this purpose, nine channels with a different pillar diameter, ranging from 5 to 0.5 μm were fabricated using state-of the-art deep-UV lithography and deep reactive ion etching (DRIE) etching technology. The obtained results strongly deviated from the theoretically expected trend, wherein the minimal plate height (H(min)) would reduce linearly with the pillar diameter. The minimal plate height decreases from 1.7 to 1.2 μm when going from 4.80 to 3.81 μm diameter pillars, but as the dimensions are further reduced, the minimal plate heights rise again to values around 2 μm. The smallest pillar diameter even produced the worst minimal plate height (4 μm). An in-depth scanning electron microscopy (SEM) inspection of the different channels clearly reveals that these findings can be attributed to the micro-fabrication limitations that are inevitably encountered when exploring the limits of deep-UV lithography and DRIE etching processes. When the target dimensions of the design approach the etching resolution limits, the band broadening increases in a strongly non-linear way with the decreased pillar dimensions. This highly non-linear relationship can be understood from first principles: when the machining error is of the order of 100-200 nm and when the target design size for the inter-pillar distance is of the order of 250 nm, this inevitably leads to pores that will range in size between 50 and 450 nm that we want to highlight with our paper highly non-linear relationship. This highly non-linear relationship can be understood from first principles: when the machining error is of the order of 100-200 nm and when the target design size for the inter-pillar distance is of the order of 250 nm, this inevitably leads to pores that will range in size between 50 and 450

  7. Simultaneous determination of multiclass preservatives including isothiazolinones and benzophenone-type UV filters in household and personal care products by micellar electrokinetic chromatography.

    Science.gov (United States)

    Lopez-Gazpio, Josu; Garcia-Arrona, Rosa; Millán, Esmeralda

    2015-04-01

    In this work, a simple and reliable micellar electrokinetic chromatography method for the separation and quantification of 14 preservatives, including isothiazolinones, and two benzophenone-type UV filters in household, cosmetic and personal care products was developed. The selected priority compounds are widely used as ingredients in many personal care products, and are included in the European Regulation concerning cosmetic products. The electrophoretic separation parameters were optimized by means of a modified chromatographic response function in combination with an experimental design, namely a central composite design. After optimization of experimental conditions, the BGE selected for the separation of the targets consisted of 60 mM SDS, 18 mM sodium tetraborate, pH 9.4 and 10% v/v methanol. The MEKC method was checked in terms of linearity, LODs and quantification, repeatability, intermediate precision, and accuracy, providing appropriate values (i.e. R(2) ≥ 0.992, repeatability RSD values ˂9%, and accuracy 90-115%). Applicability of the validated method was successfully assessed by quantifying preservatives and UV filters in commercial consumer products. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. JCE Feature Columns

    Science.gov (United States)

    Holmes, Jon L.

    1999-05-01

    The Features area of JCE Online is now readily accessible through a single click from our home page. In the Features area each column is linked to its own home page. These column home pages also have links to them from the online Journal Table of Contents pages or from any article published as part of that feature column. Using these links you can easily find abstracts of additional articles that are related by topic. Of course, JCE Online+ subscribers are then just one click away from the entire article. Finding related articles is easy because each feature column "site" contains links to the online abstracts of all the articles that have appeared in the column. In addition, you can find the mission statement for the column and the email link to the column editor that I mentioned above. At the discretion of its editor, a feature column site may contain additional resources. As an example, the Chemical Information Instructor column edited by Arleen Somerville will have a periodically updated bibliography of resources for teaching and using chemical information. Due to the increase in the number of these resources available on the WWW, it only makes sense to publish this information online so that you can get to these resources with a simple click of the mouse. We expect that there will soon be additional information and resources at several other feature column sites. Following in the footsteps of the Chemical Information Instructor, up-to-date bibliographies and links to related online resources can be made available. We hope to extend the online component of our feature columns with moderated online discussion forums. If you have a suggestion for an online resource you would like to see included, let the feature editor or JCE Online (jceonline@chem.wisc.edu) know about it. JCE Internet Features JCE Internet also has several feature columns: Chemical Education Resource Shelf, Conceptual Questions and Challenge Problems, Equipment Buyers Guide, Hal's Picks, Mathcad

  9. Comparison of microbial communities in Lake Tahoe surface sample with Tonga Trench water column samples using High Pressure Liquid Chromatography - Electrospray Ionization - Mass Spectroscopy (HPLC - ESI - MS) and Global Natural Products Social Molecular Network (GNPS)

    Science.gov (United States)

    Belmonte, M. A.

    2015-12-01

    Intact polar lipids (IPLs) are lipids composed of a head group, a glycerol, and a fatty acid chain that make up the lipid bilayer of cell membranes in living cells; and the varying head groups can be indicative of the type of microbes present in the environment (Van Mooy 2010). So by distinguishing and identifying the IPL distribution in an environment one can make inferences about the microbial communities in the said environment. In this study, we used High Pressure Liquid Chromatography-Electrospray Ionization- Mass Spectroscopy (HPLC-ESI-MS) and Global Natural Products Social Molecular Networking (GNPS) to compare the IPL distributions of two oligotrophic environments: surface waters of Lake Tahoe in the Sierra Nevada Mountains, and the water column of the Tonga Trench in the South Pacific. We hypothesized that the similar nutrient dynamics of the two oligotrophic environments would result in similar eukaryotic and prokaryotic communities, which would be reflected in the IPL composition of suspended particulate organic matter (POM). For simplicity we focused on the classes of IPLs most commonly observed in the marine environment: phosphotidylglycerol (PG), phosphotidylethanolamine (PE), diacylglyceryl-trimethyl-homoserine (DGTS), diacylglyceryl-hydroxymethyl-trimethylalanine (DGTA), sulfoquinovosyldiacylglycerol (SQDG), monoglycosyldiacylglycerol (MGDG) and diglycosyldiacylglycerol (DGDG). Our results showed that all of the marine IPLs of interest were present in Lake Tahoe which confirms that there are many of the same microbial communities in the fresh waters of Lake Tahoe and the salt waters Tonga Trench.

  10. Sample pre-treatment to eliminate cationic methylated arsenic for determining arsenite on an anion-exchange column by high performance liquid chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Huang, Jen-How; Ilgen, Gunter; Decker, Berryinne

    2008-03-17

    Co-elution of cationic methylated arsenic, e.g. arsenobetaine may interfere with the determination of arsenite on the Hamilton PRP-X100 anion-exchange column using a phosphate buffer isocratically. Therefore, a sample pre-treatment method with self-packed AG MP-50 cation-exchange cartridges was proposed, which enables the arsenite determination in samples containing arsenobetaine on a PRP-X100 column using a phosphate buffer (pH 5.6) isocratically. Methylated arsenic, including dimethylarsinic acid, trimethylarsine oxide, tetramethylarsonium ion, arsenobetaine and arsenocholine, with concentrations below 1000microgAsL(-1), may be completely retained in the AG MP-50 cartridge without any changes of arsenite, arsenate and monomethylarsonic acid speciation. Such retention was independent of the pH and matrix. It is proposed to be based on hydrophobic interaction. With the help of AG MP-50 cartridges, 11 arsenic species were detected in fish (DORM-2), mussels (BCR-477) and red algae (Porphyra tenera) in 10min on the PRP-X100 column using a phosphate buffer isocratically. Arsenite was the only minor species (up to 0.9%) among all water extractable arsenic species in fish, mussel and red algae.

  11. Liquid chromatography detection unit, system, and method

    Science.gov (United States)

    Derenzo, Stephen E.; Moses, William W.

    2015-10-27

    An embodiment of a liquid chromatography detection unit includes a fluid channel and a radiation detector. The radiation detector is operable to image a distribution of a radiolabeled compound as the distribution travels along the fluid channel. An embodiment of a liquid chromatography system includes an injector, a separation column, and a radiation detector. The injector is operable to inject a sample that includes a radiolabeled compound into a solvent stream. The position sensitive radiation detector is operable to image a distribution of the radiolabeled compound as the distribution travels along a fluid channel. An embodiment of a method of liquid chromatography includes injecting a sample that comprises radiolabeled compounds into a solvent. The radiolabeled compounds are then separated. A position sensitive radiation detector is employed to image distributions of the radiolabeled compounds as the radiolabeled compounds travel along a fluid channel.

  12. Supercritical fluid chromatography of fish, shark and seal oils

    DEFF Research Database (Denmark)

    Borch-Jensen, Christina; Mollerup, Jørgen

    1996-01-01

    Various natural and treated fish, shark liver and seal oils have been analyzed by supercritical fluid chromatography (SFC) using a non-polar capillary column. The lipids are separated according to molecular mass. The lipid groups found included free fatty acids, cholesterol, squalene, vitamins, wax...

  13. Investigation of pyrrolizidine alkaloids including their respective N-oxides in selected food products available in Hong Kong by liquid chromatography electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Chung, Stephen W C; Lam, Aaron C H

    2017-07-01

    This study determined the levels of pyrrolizidine alkaloids (PAs), including their respective N-oxides, in foodstuffs available in Hong Kong by liquid chromatography-electrospray ionisation tandem mass spectrometry. A total of 234 samples (48 food items) were collected randomly from a local market and analysed. About 50% of samples were found to contain detectable amount of PAs. Amongst the 48 food items, PAs were not detected in 11 food items, including barley flour, beef, cattle liver, pork, pig liver, chicken meat, chicken liver, milk, non-fermented tea, Melissa tea and linden tea. For those found to contain detectable PAs, the summed PA content ranged up to 11,000 µg kg -1 . The highest sum of PA content among the 37 food items calculated with lower bound was cumin seed, then followed by oregano, tarragon and herbs de Provence with ranges of 2.5-11,000, 1.5-5100, 8.0-3300 and 18-1300 µg kg -1 respectively. Among the samples, the highest sum of PA content was detected in a cumin seed sample (11,000 µg kg -1 ), followed by an oregano (5100 µg kg -1 ), a tarragon (3300 µg kg -1 ) and a herbs de Provence (1300 µg kg -1 ). In general, the results of this study agreed well with other published results in peer-reviewed journals, except that the total PAs in honey and specific tea infusion in this study were comparatively lower.

  14. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of 86 volatile organic compounds in water by gas chromatography/mass spectrometry, including detections less than reporting limits

    Science.gov (United States)

    Connor, Brooke F.; Rose, Donna L.; Noriega, Mary C.; Murtaugh, Lucinda K.; Abney, Sonja R.

    1998-01-01

    This report presents precision and accuracy data for volatile organic compounds (VOCs) in the nanogram-per-liter range, including aromatic hydrocarbons, reformulated fuel components, and halogenated hydrocarbons using purge and trap capillary-column gas chromatography/mass spectrometry. One-hundred-four VOCs were initially tested. Of these, 86 are suitable for determination by this method. Selected data are provided for the 18 VOCs that were not included. This method also allows for the reporting of semiquantitative results for tentatively identified VOCs not included in the list of method compounds. Method detection limits, method performance data, preservation study results, and blank results are presented. The authors describe a procedure for reporting low-concentration detections at less than the reporting limit. The nondetection value (NDV) is introduced as a statistically defined reporting limit designed to limit false positives and false negatives to less than 1 percent. Nondetections of method compounds are reported as ?less than NDV.? Positive detections measured at less than NDV are reported as estimated concentrations to alert the data user to decreased confidence in accurate quantitation. Instructions are provided for analysts to report data at less than the reporting limits. This method can support the use of either method reporting limits that censor detections at lower concentrations or the use of NDVs as reporting limits. The data-reporting strategy for providing analytical results at less than the reporting limit is a result of the increased need to identify the presence or absence of environmental contaminants in water samples at increasingly lower concentrations. Long-term method detection limits (LTMDLs) for 86 selected compounds range from 0.013 to 2.452 micrograms per liter (?g/L) and differ from standard method detection limits (MDLs) in that the LTMDLs include the long-term variance of multiple instruments, multiple operators, and multiple

  15. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  16. Solvent extraction columns

    International Nuclear Information System (INIS)

    Middleton, P.; Smith, J.R.

    1979-01-01

    In pulsed columns for use in solvent extraction processes, e.g. the reprocessing of nuclear fuel, the horizontal perforated plates inside the column are separated by interplate spacers manufactured from metallic neutron absorbing material. The spacer may be in the form of a spiral or concentric circles separated by radial limbs, or may be of egg-box construction. Suitable neutron absorbing materials include stainless steel containing boron or gadolinium, hafnium metal or alloys of hafnium. (UK)

  17. Development and validation of a multi-residue method for pesticide determination in honey using on-column liquid-liquid extraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Pirard, C; Widart, J; Nguyen, B K; Deleuze, C; Heudt, L; Haubruge, E; De Pauw, E; Focant, J-F

    2007-06-08

    We report on the development and validation under ISO 17025 criteria of a multi-residue confirmatory method to identify and quantify 17 widely chemically different pesticides (insecticides: Carbofuran, Methiocarb, Pirimicarb, Dimethoate, Fipronil, Imidacloprid; herbicides: Amidosulfuron, Rimsulfuron, Atrazine, Simazine, Chloroturon, Linuron, Isoxaflutole, Metosulam; fungicides: Diethofencarb) and 2 metabolites (Methiocarb sulfoxide and 2-Hydroxytertbutylazine) in honey. This method is based on an on-column liquid-liquid extraction (OCLLE) using diatomaceous earth as inert solid support and liquid chromatography (LC) coupled to mass spectrometry (MS) operating in tandem mode (MS/MS). Method specificity is ensured by checking retention time and theoretical ratio between two transitions from a single precursor ion. Linearity is demonstrated all along the range of concentration that was investigated, from 0.1 to 20 ng g(-1) raw honey, with correlation coefficients ranging from 0.921 to 0.999, depending on chemicals. Recovery rates obtained on home-made quality control samples are between 71 and 90%, well above the range defined by the EC/657/2002 document, but in the range we had fixed to ensure proper quantification, as levels found in real samples could not be corrected for recovery rates. Reproducibility is found to be between 8 and 27%. Calculated CCalpha and CCbeta (0.0002-0.943 ng g(-1) for CCalpha, and 0.0002-1.232 ng g(-1) for CCbeta) show the good sensitivity attained by this multi-residue analytical method. The robustness of the method has been tested in analyzing more than 100 raw honey samples collected from different areas in Belgium, as well as some wax and bee samples, with a slightly adapted procedure.

  18. Ochratoxin A determination in beer by immunoaffinity column clean-up and high-performance liquid chromatography Determinação de ocratoxina A em cerveja por coluna de imunoafinidade e cromatografia líquida

    Directory of Open Access Journals (Sweden)

    Guilherme Prado

    2003-12-01

    Full Text Available Analyses of ochratoxin A (OTA in domestic and imported beers were perfomed by immunoaffinity column and high - perfomance liquid chromatography (HPLC using a fluorescence detector. Recoveries of OTA from beer samples spiked at levels from 8.0 to 800pg/mL ranged from 81.2% to 95.0%, with coefficient of variation between 0% e 11.0%. Detection limit and quantification limit were 2.0pg/mL and 8.0pg/mL, respectively. Of the total of 26 samples produced in Brazil only 6 (23%, contained trace amounts of OTA. Of the 4 imported beers, in 2, Ireland and Germany, were detected OTA at levels of 25pg/mL and 82pg/mL, respectively.Análises de ocratoxina A em cervejas nacionais e importadas foram executadas por coluna de imunoafinidade e cromatografia líquida de alta eficiência (CLAE com detetor de fluorescência. Recuperações de ocratoxina A em amostras de cervejas contaminadas em níveis de 8.0 a 800pg/mL, foram de 81,2% a 95%, com coeficiente de variação entre 0% e 11%. O limite de detecção e o de quantificação foram 2.0pg/mL e 8.0pg/mL, respectivamente. De um total de 26 amostras fabricadas no Brasil, somente 6 (23% apresentavam traços (pg/mL de ocratoxina A. Das 4 amostras de cerveja importadas analisadas, em duas, Irlanda e Alemanha, foram detectadas ocratoxina A em níveis de 25pg/mL e 82pg/mL, respectivamente.

  19. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory : determination of organophosphate pesticides in whole water by continuous liquid-liquid extraction and capillary-column gas chromatography with flame photometric detection

    Science.gov (United States)

    Jha, Virendra K.; Wydoski, Duane S.

    2003-01-01

    A method for the isolation of 20 parent organophosphate pesticides and 5 organophosphate pesticide degradates from natural-water samples is described. Compounds are extracted from water samples with methylene chloride using a continuous liquid-liquid extractor for 6 hours. The solvent is evaporated using heat and a flow of nitrogen to a volume of 1 milliliter and solvent exchanged to ethyl acetate. Extracted compounds are determined by capillary-column gas chromatography with flame photometric detection. Single-operator derived method detection limits in three water-matrix samples ranged from 0.003 to 0.009 microgram per liter. Method performance was validated by spiking all compounds in three different matrices at three different concentrations. Eight replicates were analyzed at each concentration in each matrix. Mean recoveries of most method compounds spiked in surface-water samples ranged from 54 to 137 percent and those in ground-water samples ranged from 40 to 109 percent for all pesticides. Recoveries in reagent-water samples ranged from 42 to 104 percent for all pesticides. The only exception was O-ethyl-O-methyl-S-propylphosphorothioate, which had variable recovery in all three matrices ranging from 27 to 79 percent. As a result, the detected concentration of O-ethyl-O-methyl-S-propylphosphorothioate in samples is reported in this method with an estimated remark code. Based on the performance issue, two more compounds, disulfoton and ethion monoxon, also will be reported in this method with an estimated remark code. Estimated-value compounds, which are ?E-coded? in the data base, do not meet the performance criteria for unqualified quantification, but are retained in the method because the compounds are important owing to high use or potential environmental effects and because analytical performance has been consistent and reproducible.

  20. Ion-pair in-tube solid-phase microextraction and capillary liquid chromatography using a titania-based column: application to the specific lauralkonium chloride determination in water.

    Science.gov (United States)

    Prieto-Blanco, M C; Moliner-Martínez, Y; López-Mahía, P; Campíns-Falcó, P

    2012-07-27

    A quick, miniaturized and on-line method has been developed for the determination in water of the predominant homologue of benzalkonium chloride, dodecyl dimethyl benzyl ammonium chloride or lauralkonium chloride (C(12)-BAK). The method is based on the formation of an ion-pair in both in-tube solid-phase microextraction (IT-SPME) and capillary liquid chromatography. The IT-SPME optimization required the study of the length and nature of the stationary phase of capillary and the processed sample volume. Because to the surfactant character of the analyte both, the extracting and replacing solvents, have played a decisive role in the IT-SPME optimized procedure. Conditioning the capillary with the mobile phase which contains the counter ion (acetate), using an organic additive (tetrabutylammonium chloride) added to the sample and a mixture water/methanol as replacing solvent (processed just before the valve is switched to the inject position), allowed to obtain good precision of the retention time and a narrow peak for C(12)-BAK. A reversed-phase capillary based TiO(2) column and a mobile phase containing ammonium acetate at pH 5.0 for controlling the interactions of cationic surfactant with titania surface were proposed. The optimized procedure provided adequate linearity, accuracy and precision at the concentrations interval of 1.5-300 μg L(-1) .The limit of detection (LOD) was 0.5 μg L(-1) using diode array detection (DAD). The applicability of proposed IT-SPME-capillary LC method has been assessed in several water samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Determination of glyphosate residuals and of their metabolite Aminomethyl-Phosphonic acid in waters, by means of liquid chromatography of high efficiency with post-column derivation and fluorescence detection

    International Nuclear Information System (INIS)

    Rodriguez, Hugo A; Guerrero, Jairo; Castro, Rene

    2002-01-01

    The glyphosate is a no selective herbicide largely used in the world in order to control annual and perennial weeds. Its principal metabolite in soils and waters is the Aminomethyl-Phosphonic Acid (AMPA) formed by micro organism's action. This herbicide is used in Colombia in high doses to illegal crops eradication of coca and Amapola and like natural accelerator in sugar cane, constituting an environmental and social problem for the country, being necessary the evaluation of glyphosate residues in different matrices. This study describes the validation of the analytical methodology for the simultaneous determination of glyphosate and its metabolite AMPA in waters of some Colombian regions. The experimental procedure pointed out two main steps: the first one was a cleaning, extraction and concentration step by solid phase extraction; the second step is the separation, identification and quantification of the compounds by High Performance Liquid Chromatography (HPLC) with post-column derivation and fluorescence detection. The results of the validation show that the methodology is specific, selective, precise and robust with linear calibration curve in the linear range between 10 and 750 μg/L, with limits of detection of 0.8 μg/L and limits of quantification of 2 μg/L for the two analyses. The recoveries are in the order of 73% for glyphosate and 70% for AMPA. More over analysis results are presented for water samples of some country regions where glyphosate is applied in different doses with different purposes, finding residues of the herbicide and its metabolite in concentrations above the allowed values in drinking waters for pesticides of toxicology category IV, like the glyphosate, according with the Colombian legislation

  2. Preparation and application of organic-silica hybrid monolithic capillary columns.

    Science.gov (United States)

    Wu, Minghuo; Wu, Ren'an; Zhang, Zhenbin; Zou, Hanfa

    2011-01-01

    Organic-silica hybrid monolithic columns have drawn more and more attention due to the ease of preparation and good mechanical stability in recent years. Many synthetic approaches have been developed and a variety of hybrid monolithic capillary columns have been prepared. The sol-gel process is well recognized in the fabrication of hybrid monolithic columns, which can be mainly classified as one-step, acid/base two-step procedures. The new approaches such as the "one-pot" and nano-scaled inorganic-organic hybrid reagent of polyhedral oligomeric silsesquioxane used as a cross-linker have also emerged for the preparation of hybrid monolithic columns. The applications of the organic-silica hybrid monolithic capillary columns for capillary electrochromatography, micro high-performance liquid chromatography, solid-phase micro-extraction and enzymatic reactor etc. are included in this review. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Report: Affinity Chromatography.

    Science.gov (United States)

    Walters, Rodney R.

    1985-01-01

    Supports, affinity ligands, immobilization, elution methods, and a number of applications are among the topics considered in this discussion of affinity chromatography. An outline of the basic principles of affinity chromatography is included. (JN)

  4. Preparation and application of hydrophilic monolithic columns.

    Science.gov (United States)

    Jiang, Zhengjin; Smith, Norman William; Liu, Zhenghua

    2011-04-29

    Hydrophilic interaction chromatography (HILIC) has experienced increasing attention in recent years. Much research has been carried out in the area of HILIC separation mechanisms, column techniques and applications. Because of their good permeability, low resistance to mass transfer and easy preparation within capillaries, hydrophilic monolithic columns represent a trend among novel HILIC column techniques. This review attempts to present an overview of the preparation and applications of HILIC monolithic columns carried out in the past decade. The separation mechanism of various hydrophilic monolithic stationary phases is also reviewed. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Recent advances in column switching sample preparation in bioanalysis.

    Science.gov (United States)

    Kataoka, Hiroyuki; Saito, Keita

    2012-04-01

    Column switching techniques, using two or more stationary phase columns, are useful for trace enrichment and online automated sample preparation. Target fractions from the first column are transferred online to a second column with different properties for further separation. Column switching techniques can be used to determine the analytes in a complex matrix by direct sample injection or by simple sample treatment. Online column switching sample preparation is usually performed in combination with HPLC or capillary electrophoresis. SPE or turbulent flow chromatography using a cartridge column and in-tube solid-phase microextraction using a capillary column have been developed for convenient column switching sample preparation. Furthermore, various micro-/nano-sample preparation devices using new polymer-coating materials have been developed to improve extraction efficiency. This review describes current developments and future trends in novel column switching sample preparation in bioanalysis, focusing on innovative column switching techniques using new extraction devices and materials.

  6. Determination of Single Sugars, Including Inulin, in Plants and Feed Materials by High-Performance Liquid Chromatography and Refraction Index Detection

    Directory of Open Access Journals (Sweden)

    Kirsten Weiß

    2017-08-01

    Full Text Available The exact and reliable detection of sugar monomers and fructans provides important information for the evaluation of carbohydrate metabolism in plants and animals. Using the HPLC method; a large number of samples and single sugars; with both high sensitivity and selectivity; may be analysed. It was shown that the described method—using a Nucleosil column loaded with Pb2+ ions; a refractive index detector (RID; and HPLC-grade water as the eluent—gives precise and reproducible results regarding the detection of individual sugars in extracts of plants and feed materials. The method can be applied for the detection of sucrose; maltose; lactose; xylose; glucose; galactose; arabinose; fructose; ribose; and mannitol. Furthermore; depending on the plant material; the sugars verbascose; stachyose; and raffinose can be separated. The peaks were well resolved and the reproducibility of the analysis; with 94–108% of recovery (RC and relative standard deviation (RSD of up to 5%; was very good. The method was successfully applied to a variety of green forages and samples of sugar beet pulp silages. It is also possible to determine fructan with inulin as a standard; together with the other sugars; or alone by a different protocol and column.

  7. Simultaneous analysis of circulating 25-hydroxy-vitamin D3, 25-hydroxy-vitamin D2, retinol, tocopherols, carotenoids, and oxidized and reduced coenzyme Q10 by high performance liquid chromatography with photo diode-array detection using C18 and C30 columns alone or in combination.

    Science.gov (United States)

    Franke, Adrian A; Morrison, Cynthia M; Custer, Laurie J; Li, Xingnan; Lai, Jennifer F

    2013-08-02

    Circulating lipid-phase micronutrients (LPM) such as 25-hydroxylated D vitamers, retinol, tocopherols, carotenoids including their isomers, and coenzyme Q10 play important roles in health maintenance and disease prevention and can serve as useful biomarkers. We developed fast, affordable, and accurate HPLC assays that simultaneously measured all above LPM in a single run using UV/VIS detection at 265nm, 295nm, and 480nm with (1) a C18 column alone; (2) a C30 column alone; or (3) each of these columns connected in series. The C18 column alone could separate all major LPM of interest in less than 17min but insufficiently resolved the lycopene isomers, the 25-hydroxylated D vitamers, lutein from zeaxanthin and β- from γ-tocopherol. The C30 column alone separated all LPM of interest including many isomeric analytes but failed to resolve the Q10 compounds, which co-eluted with carotenoids. Connecting the C18 and C30 columns in series with a detector after the C30 column and a pressure resistant detector between the columns resulted in ideal resolution and accurate quantitation of all LPM of interest but required software capable of processing the acquired data from both detectors. Connecting the C18 and C30 columns in series with exclusively one detector after the C30 column resulted in carotenoid-Q10 interferences, however, this was remedied by heart-cutting 2D-LC with a 6-port valve between the columns, which resolved all analytes in 42min. Faster run times led to some analytes not being resolved. Many variations of these methods are possible to meet the needs of individual requirements while minimizing sample material and turn-around-times. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Thermally stable dexsil-400 glass capillary columns

    International Nuclear Information System (INIS)

    Maskarinec, M.P.; Olerich, G.

    1980-01-01

    The factors affecting efficiency, thermal stability, and reproducibility of Dexsil-400 glass capillary columns for gas chromatography in general, and for polycyclic aromatic hydrocarbons (PAHs) in particular were investigated. Columns were drawn from Kimble KG-6 (soda-lime) glass or Kimox (borosilicate) glass. All silylation was carried out at 200 0 C. Columns were coated according to the static method. Freshly prepared, degassed solutions of Dexsil-400 in pentane or methylene chloride were used. Thermal stability of the Dexsil 400 columns with respect to gas chromatography/mass spectrometry (GC/MS) were tested. Column-to-column variability is a function of each step in the fabrication of the columns. The degree of etching, extent of silylation, and stationary phase film thickness must be carefully controlled. The variability in two Dexsil-400 capillary column prepared by etching, silylation with solution of hexa methyl disilazone (HMDS), and static coating is shown and also indicates the excellent selectivity of Dexsil-400 for the separation of alkylated aromatic compounds. The wide temperature range of Dexsil-400 and the high efficiency of the capillary columns also allow the analysis of complex mixtures with minimal prefractionation. Direct injection of a coal liquefaction product is given. Analysis by GC/MS indicated the presence of parent PAHs, alkylated PAHs, nitrogen and sulfur heterocycles, and their alkylated derivatives. 4 figures

  9. Determination of drugs in surface water and wastewater samples by liquid chromatography-mass spectrometry: Methods and preliminary results including toxicity studies with Vibrio fischeri

    Science.gov (United States)

    Farre, M.; Ferrer, I.; Ginebreda, A.; Figueras, M.; Olivella, L.; Tirapu, L.; Vilanova, M.; Barcelo, D.

    2001-01-01

    In the present work a combined analytical method involving toxicity and liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) was developed for the determination of pharmaceutical compounds in water samples. The drugs investigated were the analgesics: ibuprofen, ketoprofen, naproxen, and diclofenac, the decomposition product of the acetyl salicylic acid: salicylic acid and one lipid lowering agent, gemfibrozil. The selected compounds are acidic substances, very polar and all of them are analgesic compounds that can be purchased without medical prescription. The developed protocol consisted, first of all, on the use Microtox?? and ToxAlert??100 toxicity tests with Vibrio fischeri for the different pharmaceutical drugs. The 50% effective concentration (EC50) values and the toxicity units (TU) were determined for every compound using both systems. Sample enrichment of water samples was achieved by solid-phase extraction procedure (SPE), using the Merck LiChrolut?? EN cartridges followed by LC-ESI-MS. Average recoveries loading 1 l of samples with pH=2 varied from 69 to 91% and the detection limits in the range of 15-56 ng/l. The developed method was applied to real samples from wastewater and surface-river waters of Catalonia (north-east of Spain). One batch of samples was analyzed in parallel also by High Resolution Gas Chromatography coupled with Mass Spectrometry (HRGC-MS) and the results have been compared with the LC-ESI-MS method developed in this work. ?? 2001 Elsevier Science B.V. All rights reserved.

  10. Buckling of a holey column.

    Science.gov (United States)

    Pihler-Puzović, D; Hazel, A L; Mullin, T

    2016-09-14

    We report the results from a combined experimental and numerical investigation of buckling in a novel variant of an elastic column under axial load. We find that including a regular line of centred holes in the column can prevent conventional, global, lateral buckling. Instead, the local microstructure introduced by the holes allows the column to buckle in an entirely different, internal, mode in which the holes are compressed in alternate directions, but the column maintains the lateral reflection symmetry about its centreline. The internal buckling mode can be accommodated within a smaller external space than the global one; and it is the preferred buckling mode over an intermediate range of column lengths for sufficiently large holes. For very short or sufficiently long columns a modification of the classical, global, lateral buckling is dominant.

  11. Stationary phases for superheated water chromatography

    CERN Document Server

    Saha, S

    2002-01-01

    This project focused on the comparison of conventional liquid chromatography and superheated water chromatography. It examined the differences in efficiency and retention of a range of different stationary phases. Alkyl aryl ketones and eight aromatic compounds were separated on PBD-zirconia, Xterra RP 18, Luna C sub 1 sub 8 (2) and Oasis HLB columns using conventional LC and superheated water chromatography system. The retention indices were determined in the different eluents. On changing the organic component of the eluent from methanol to acetonitrile to superheated water considerable improvements were found in the peak shapes and column efficiencies on the PBD-zirconia and Oasis HLB columns. PS-DVB, PBD-zirconia and Xterra RP 18 columns have been used in efficiency studies. It was found that simply elevating the column temperature did not increase the efficiency of a separation in superheated water chromatography. The efficiency depended on flow rate, injection volume and also mobile phase preheating sys...

  12. Atomic Force Microscope Mediated Chromatography

    Science.gov (United States)

    Anderson, Mark S.

    2013-01-01

    The atomic force microscope (AFM) is used to inject a sample, provide shear-driven liquid flow over a functionalized substrate, and detect separated components. This is demonstrated using lipophilic dyes and normal phase chromatography. A significant reduction in both size and separation time scales is achieved with a 25-micron-length column scale, and one-second separation times. The approach has general applications to trace chemical and microfluidic analysis. The AFM is now a common tool for ultra-microscopy and nanotechnology. It has also been demonstrated to provide a number of microfluidic functions necessary for miniaturized chromatography. These include injection of sub-femtoliter samples, fluidic switching, and sheardriven pumping. The AFM probe tip can be used to selectively remove surface layers for subsequent microchemical analysis using infrared and tip-enhanced Raman spectroscopy. With its ability to image individual atoms, the AFM is a remarkably sensitive detector that can be used to detect separated components. These diverse functional components of microfluidic manipulation have been combined in this work to demonstrate AFM mediated chromatography. AFM mediated chromatography uses channel-less, shear-driven pumping. This is demonstrated with a thin, aluminum oxide substrate and a non-polar solvent system to separate a mixture of lipophilic dyes. In conventional chromatographic terms, this is analogous to thin-layer chromatography using normal phase alumina substrate with sheardriven pumping provided by the AFM tip-cantilever mechanism. The AFM detection of separated components is accomplished by exploiting the variation in the localized friction of the separated components. The AFM tip-cantilever provides the mechanism for producing shear-induced flows and rapid pumping. Shear-driven chromatography (SDC) is a relatively new concept that overcomes the speed and miniaturization limitations of conventional liquid chromatography. SDC is based on a

  13. Large scale chromatographic separations using continuous displacement chromatography (CDC)

    International Nuclear Information System (INIS)

    Taniguchi, V.T.; Doty, A.W.; Byers, C.H.

    1988-01-01

    A process for large scale chromatographic separations using a continuous chromatography technique is described. The process combines the advantages of large scale batch fixed column displacement chromatography with conventional analytical or elution continuous annular chromatography (CAC) to enable large scale displacement chromatography to be performed on a continuous basis (CDC). Such large scale, continuous displacement chromatography separations have not been reported in the literature. The process is demonstrated with the ion exchange separation of a binary lanthanide (Nd/Pr) mixture. The process is, however, applicable to any displacement chromatography separation that can be performed using conventional batch, fixed column chromatography

  14. Numerical Simulation of Fluid Dynamics in a Monolithic Column

    Directory of Open Access Journals (Sweden)

    Kazuhiro Yamamoto

    2017-01-01

    Full Text Available As for the measurement of polycyclic aromatic hydrocarbons (PAHs, ultra-performance liquid chromatography (UPLC is used for PAH identification and densitometry. However, when a solvent containing a substance to be identified passes through a column of UPLC, a dedicated high-pressure-proof device is required. Recently, a liquid chromatography instrument using a monolithic column technology has been proposed to reduce the pressure of UPLC. The present study tested five types of monolithic columns produced in experiments. To simulate the flow field, the lattice Boltzmann method (LBM was used. The velocity profile was discussed to decrease the pressure drop in the ultra-performance liquid chromatography (UPLC system.

  15. Reversed-phase liquid chromatography with electrospray mass detection and 1H and 13C NMR characterization of new process-related impurities, including forced degradants of efavirenz: related substances correlated to the synthetic pathway.

    Science.gov (United States)

    Gadapayale, Kamalesh; Kakde, Rajendra; Sarma, V U M

    2015-01-01

    In this study, a stability-indicating reversed-phase liquid chromatographic electrospray mass spectrometric method was developed and validated for the determination of process-related impurities and forced degradants of Efavirenz in bulk drugs. Efavirenz was subjected to acid, alkaline hydrolysis, H2O2 oxidation, photolysis, and thermal stress. Significant degradation was observed during alkaline hydrolysis, and the degradants were isolated on a mass-based purification system and characterized by high-resolution mass spectrometry, positive electrospray ionization tandem mass spectrometry, and (1)H and (13)C NMR spectroscopy. Accurate mass measurement and NMR spectroscopy revealed the possible structure of process-related impurities and degradant under stress conditions. The acceptable separation was accomplished on Waters bondapak C18 column (250 mm × 4.6 mm; 5 μm), using 5 mM ammonium acetate and acetonitrile as a mobile phase in a gradient elution mode at a flow rate of 1.0 mL/min. The eluents were monitored by diode array detector at 247 nm and quantitation limits were obtained in the range of 0.1-2.5 μg/mL for Efavirenz, degradants, and process-related impurities. The liquid chromatography method was validated with respect to accuracy, precision, linearity, robustness, and limits of detection and quantification as per International Conference on Harmonization guidelines. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Deformation and degradation of polymers in ultra-high-pressure liquid chromatography

    NARCIS (Netherlands)

    Uliyanchenko, E.; van der Wal, S.; Schoenmakers, P.J.

    2011-01-01

    Ultra-high-pressure liquid chromatography (UHPLC) using columns packed with sub-2 μm particles has great potential for separations of many types of complex samples, including polymers. However, the application of UHPLC for the analysis of polymers meets some fundamental obstacles. Small particles

  17. Admittance Scanning for Whole Column Detection.

    Science.gov (United States)

    Stamos, Brian N; Dasgupta, Purnendu K; Ohira, Shin-Ichi

    2017-07-05

    Whole column detection (WCD) is as old as chromatography itself. WCD requires an ability to interrogate column contents from the outside. Other than the obvious case of optical detection through a transparent column, admittance (often termed contactless conductance) measurements can also sense changes in the column contents (especially ionic content) from the outside without galvanic contact with the solution. We propose here electromechanically scanned admittance imaging and apply this to open tubular (OT) chromatography. The detector scans across the column; the length resolution depends on the scanning velocity and the data acquisition frequency, ultimately limited by the physical step resolution (40 μm in the present setup). Precision equal to this step resolution was observed for locating an interface between two immiscible liquids inside a 21 μm capillary. Mechanically, the maximum scanning speed was 100 mm/s, but at 1 kHz sampling rate and a time constant of 25 ms, the highest practical scan speed (no peak distortion) was 28 mm/s. At scanning speeds of 0, 4, and 28 mm/s, the S/N for 180 pL (zone length of 1.9 mm in a 11 μm i.d. column) of 500 μM KCl injected into water was 6450, 3850, and 1500, respectively. To facilitate constant and reproducible contact with the column regardless of minor variations in outer diameter, a double quadrupole electrode system was developed. Columns of significant length (>1 m) can be readily scanned. We demonstrate its applicability with both OT and commercial packed columns and explore uniformity of retention along a column, increasing S/N by stopped-flow repeat scans, etc. as unique applications.

  18. Water Column Sonar Data Collection

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The collection and analysis of water column sonar data is a relatively new avenue of research into the marine environment. Primary uses include assessing biological...

  19. [Plant drugs with residues of organochlorine compounds. 2. Identification of residues of DDT and its analogs by comparison of gas chromatography on packed and capillary columns and GC/MS coupling].

    Science.gov (United States)

    Benecke, R; Brotka, J; Wijsbeek, J; Franke, J P; Bruins, A P; de Zeeuw, R A

    1986-07-01

    For the GC analysis of DDT isomers and metabolites in extracts of Flores Chamomillae end Radix Valerianae the separation on a packed QF-1/OV-17 column was compared with various capillary columns of the CP-Sil type. Identification of the individual compounds could be achieved by comparing the retention behavior, chemical transformation of DDT and DDE, as well as by capillary GC-MS using single ion monitoring of substance-characteristic ion mass. In this way, residues of p,p'-DDT, o,p'-DDE and p,p'-TDE could be identified.

  20. Spiral Countercurrent Chromatography

    Science.gov (United States)

    Ito, Yoichiro; Knight, Martha; Finn, Thomas M.

    2013-01-01

    For many years, high-speed countercurrent chromatography conducted in open tubing coils has been widely used for the separation of natural and synthetic compounds. In this method, the retention of the stationary phase is solely provided by the Archimedean screw effect by rotating the coiled column in the centrifugal force field. However, the system fails to retain enough of the stationary phase for polar solvent systems such as the aqueous–aqueous polymer phase systems. To address this problem, the geometry of the coiled channel was modified to a spiral configuration so that the system could utilize the radially acting centrifugal force. This successfully improved the retention of the stationary phase. Two different types of spiral columns were fabricated: the spiral disk assembly, made by stacking multiple plastic disks with single or four interwoven spiral channels connected in series, and the spiral tube assembly, made by inserting the tetrafluoroethylene tubing into a spiral frame (spiral tube support). The capabilities of these column assemblies were successfully demonstrated by separations of peptides and proteins with polar two-phase solvent systems whose stationary phases had not been well retained in the earlier multilayer coil separation column for high-speed countercurrent chromatography. PMID:23833207

  1. [Analysis of residues of organochlorine compounds in plant drugs. 3. Identification of residues of polychlorobiphenyl compounds by comparison of gas chromatography on packed and capillary columns and GCMS coupling].

    Science.gov (United States)

    Benecke, R; Brotka, J; Wijsbeek, J; Franke, J P; Bruins, A P; de Zeeuw, R A

    1988-02-01

    The identification of residues of polychlorinated biphenyls in a test sample of Flores Chamomillae could be achieved by the retention behavior at gas chromatographic analyses on packed and capillary columns compared with reference standard Clophen A 60, respectively as well as well by capillary GC/MS using single ion monitoring of substance-characteristic ion mass.

  2. Design concept of control system for cryogenic distillation columns of fusion reactor

    International Nuclear Information System (INIS)

    Yamanishi, Toshihiko; Okuno, Kenji

    1993-09-01

    Control systems were designed for cryogenic distillation columns in the main fuel cycle and the breeder blanket interface systems of fusion reactors. Three basic control modes were proposed for the column whose top product was more important; the column whose bottom product is more important; and the column having a feed back stream. The key component in the important product stream was selected for each column, and the analysis method for measurement of this key component was discussed. Some of the columns need the gas chromatography as the analysis instrument of the control system. The time required for the measurement of product purity by the gas chromatography considerably affects the stability of the control system. A significant conclusion is that permissible time is about 20 min. It is possible to complete the measurement within 20 minute by the gas chromatography. The gas chromatography is applicable for the control system of the column. (author)

  3. Automated mini-column solid-phase extraction cleanup for high-throughput analysis of chemical contaminants in foods by low-pressure gas chromatography – tandem mass spectrometry

    Science.gov (United States)

    This study demonstrated the application of an automated high-throughput mini-cartridge solid-phase extraction (mini-SPE) cleanup for the rapid low-pressure gas chromatography – tandem mass spectrometry (LPGC-MS/MS) analysis of pesticides and environmental contaminants in QuEChERS extracts of foods. ...

  4. Methacrylate monolithic capillary columns for gradient peptide separations

    NARCIS (Netherlands)

    Pruim, P.; Öhman, M.; Huo, Y.; Schoenmakers, P.J.; Kok, W.Th.

    2008-01-01

    For the separation of peptides with gradient-elution liquid chromatography a poly(butyl methacrylate-co-ethylene dimethacrylate) (BMA) monolithic capillary column was prepared and tested. The conditional peak capacity was used as a metric for the performance of this column, which was compared with a

  5. Deformation and degradation of polymers in ultra-high-pressure liquid chromatography.

    Science.gov (United States)

    Uliyanchenko, Elena; van der Wal, Sjoerd; Schoenmakers, Peter J

    2011-09-28

    Ultra-high-pressure liquid chromatography (UHPLC) using columns packed with sub-2 μm particles has great potential for separations of many types of complex samples, including polymers. However, the application of UHPLC for the analysis of polymers meets some fundamental obstacles. Small particles and narrow bore tubing in combination with high pressures generate significant shear and extensional forces in UHPLC systems, which may affect polymer chains. At high stress conditions flexible macromolecules may become extended and eventually the chemical bonds in the molecules can break. Deformation and degradation of macromolecules will affect the peak retention and the peak shape in the chromatogram, which may cause errors in the obtained results (e.g. the calculated molecular-weight distributions). In the present work we explored the limitations of UHPLC for the analysis of polymers. Degradation and deformation of macromolecules were studied by collecting and re-injecting polymer peaks and by off-line two-dimensional liquid chromatography. Polystyrene standards with molecular weight of 4 MDa and larger were found to degrade at UHPLC conditions. However, for most polymers degradation could be avoided by using low linear velocities. No degradation of 3-MDa PS (and smaller) was observed at linear velocities up to 7 mm/s. The column frits were implicated as the main sources of polymer degradation. The extent of degradation was found to depend on the type of the column and on the column history. At high flow rates degradation was observed without a column being installed. We demonstrated that polymer deformation preceded degradation. Stretched polymers eluted from the column in slalom chromatography mode (elution order opposite to that in SEC or HDC). Under certain conditions we observed co-elution of large and small PS molecules though a convolution of slalom chromatography and hydrodynamic chromatography. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Radial Chromatography for the Separation of Nitroaniline Isomers

    Science.gov (United States)

    Miller, Robert B.; Case, William S.

    2011-01-01

    Separation techniques are usually presented in the undergraduate organic laboratory to teach students how to purify and isolate compounds. Often the concept of liquid chromatography is introduced by having students create "silica gel columns" to separate components of a reaction mixture. Although useful, column chromatography can be a laborious…

  7. PHARMACEUTICAL AND BIOMEDICAL APPLICATIONS OF AFFINITY CHROMATOGRAPHY: RECENT TRENDS AND DEVELOPMENTS

    Science.gov (United States)

    Hage, David S.; Anguizola, Jeanethe A.; Bi, Cong; Li, Rong; Matsuda, Ryan; Papastavros, Efthimia; Pfaunmiller, Erika; Vargas, John; Zheng, Xiwei

    2012-01-01

    Affinity chromatography is a separation technique that has become increasingly important in work with biological samples and pharmaceutical agents. This method is based on the use of a biologically-related agent as a stationary phase to selectively retain analytes or to study biological interactions. This review discusses the basic principles behind affinity chromatography and examines recent developments that have occurred in the use of this method for biomedical and pharmaceutical analysis. Techniques based on traditional affinity supports are discussed, but an emphasis is placed on methods in which affinity columns are used as part of HPLC systems or in combination with other analytical methods. General formats for affinity chromatography that are considered include step elution schemes, weak affinity chromatography, affinity extraction and affinity depletion. Specific separation techniques that are examined include lectin affinity chromatography, boronate affinity chromatography, immunoaffinity chromatography, and immobilized metal ion affinity chromatography. Approaches for the study of biological interactions by affinity chromatography are also presented, such as the measurement of equilibrium constants, rate constants, or competition and displacement effects. In addition, related developments in the use of immobilized enzyme reactors, molecularly imprinted polymers, dye ligands and aptamers are briefly considered. PMID:22305083

  8. Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters.

    Science.gov (United States)

    Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz

    2016-01-21

    This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis.

  9. Modeling Stone Columns.

    Science.gov (United States)

    Castro, Jorge

    2017-07-11

    This paper reviews the main modeling techniques for stone columns, both ordinary stone columns and geosynthetic-encased stone columns. The paper tries to encompass the more recent advances and recommendations in the topic. Regarding the geometrical model, the main options are the "unit cell", longitudinal gravel trenches in plane strain conditions, cylindrical rings of gravel in axial symmetry conditions, equivalent homogeneous soil with improved properties and three-dimensional models, either a full three-dimensional model or just a three-dimensional row or slice of columns. Some guidelines for obtaining these simplified geometrical models are provided and the particular case of groups of columns under footings is also analyzed. For the latter case, there is a column critical length that is around twice the footing width for non-encased columns in a homogeneous soft soil. In the literature, the column critical length is sometimes given as a function of the column length, which leads to some disparities in its value. Here it is shown that the column critical length mainly depends on the footing dimensions. Some other features related with column modeling are also briefly presented, such as the influence of column installation. Finally, some guidance and recommendations are provided on parameter selection for the study of stone columns.

  10. Profiling of drug binding proteins by monolithic affinity chromatography in combination with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Xuepei; Wang, Tongdan; Zhang, Hanzhi; Han, Bing; Wang, Lishun; Kang, Jingwu

    2014-09-12

    A new approach for proteome-wide profiling drug binding proteins by using monolithic capillary affinity chromatography in combination with HPLC-MS/MS is reported. Two immunosuppresive drugs, namely FK506 and cyclosporin A, were utilized as the experimental models for proof-of-concept. The monolithic capillary affinity columns were prepared through a single-step copolymerization of the drug derivatives with glycidyl methacrylate and ethylene dimethacrylate. The capillary chromatography with the affinity monolithic column facilitates the purification of the drug binding proteins from the cell lysate. By combining the capillary affinity column purification and the shot-gun proteomic analysis, totally 33 FK506- and 32 CsA-binding proteins including all the literature reported target proteins of these two drugs were identified. Among them, two proteins, namely voltage-dependent anion-selective channel protein 1 and serine/threonine-protein phosphatase PGAM5 were verified by using the recombinant proteins. The result supports that the monolithic capillary affinity chromatography is likely to become a valuable tool for profiling of binding proteins of small molecular drugs as well as bioactive compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Determination of sulfonamides in bovine milk with column-switching high performance liquid chromatography using surface imprinted silica with hydrophilic external layer as restricted access and selective extraction material.

    Science.gov (United States)

    Xu, Wenjuan; Su, Shufang; Jiang, Ping; Wang, Huaisong; Dong, Xiangchao; Zhang, Min

    2010-11-12

    A novel restricted access-molecularly imprinted material (RA-MIP) with selectivity for sulfonamides was synthesized using initiator-transfer agent-terminator (iniferter) method, a "living"/controlled radical polymerization technique. The material was prepared by grafting two layers with different functions on the silica support. To perform a "grafting from" polymerization, iniferter was immobilized on the surface of silica. The internal sulfamethazine imprinted polymer and the external poly(glycidyl methacrylate) [poly(GMA)] were then grafted successively. The hydrophilic structures were formed on the external layer of the material by the hydrolysis of the linear poly(GMA) for protein removal. The result has shown that this restricted access-MIP grafted silica (RA-MIP-SG) not only has the selectivity for the template and its analog, but also has the ability of exclusion for bovine serum albumin (BSA). It indicated that the material possesses both properties of molecularly imprinted polymer (MIP) and restricted access material (RAM). Using RA-MIP-SG as pre-column, a column-switching HPLC method was established for the determination of sulfonamides in bovine milk. Direct sample injection was performed in the analysis, which provides a convenient analytical procedure. Good linearity in the range of 2-400 ng mL(-1) (R>0.998) has been obtained for seven sulfonamides in the study. The recoveries of all the analytes at three concentration levels are between 93% and 107% with the RSDsulfonamides in bovine milk by direct injection and column-switching HPLC with good efficiency and reliability. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Separation of cannabinoids on three different mixed-mode columns containing carbon/nanodiamond/amine-polymer superficially porous particles.

    Science.gov (United States)

    Hung, Chuan-Hsi; Zukowski, Janusz; Jensen, David S; Miles, Andrew J; Sulak, Clayton; Dadson, Andrew E; Linford, Matthew R

    2015-09-01

    Three mixed-mode high-performance liquid chromatography columns packed with superficially porous carbon/nanodiamond/amine-polymer particles were used to separate mixtures of cannabinoids. Columns evaluated included: (i) reversed phase (C18 ), weak anion exchange, 4.6 × 33 mm, 3.6 μm, and 4.6 × 100 mm, 3.6 μm, (ii) reversed phase, strong anion exchange (quaternary amine), 4.6×33 mm, 3.6 μm, and (iii) hydrophilic interaction liquid chromatography, 4.6 × 150 mm, 3.6 μm. Different selectivities were achieved under various mobile phase and stationary phase conditions. Efficiencies and peak capacities were as high as 54 000 N/m and 56, respectively. The reversed phase mixed-mode column (C18 ) retained tetrahydrocannabinolic acid strongly under acidic conditions and weakly under basic conditions. Tetrahydrocannabinolic acid was retained strongly on the reversed phase, strong anion exchange mixed-mode column under basic polar organic mobile phase conditions. The hydrophilic interaction liquid chromatography column retained polar cannabinoids better than the (more) neutral ones under basic conditions. A longer reversed phase (C18 ) mixed-mode column (4.6 × 100 mm) showed better resolution for analytes (and a contaminant) than a shorter column. Fast separations were achieved in less than 5 min and sometimes 2 min. A real world sample (bubble hash extract) was also analyzed by gradient elution. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. ( Anogeissus leiocarpus ) timber columns

    African Journals Online (AJOL)

    A procedure for designing axially loaded Ayin (Anogeissus leiocarpus) wood column or strut has been investigated. Instead of the usual categorization of columns into short, intermediate and slender according to the value of slenderness ratio, a continuous column formula representing the three categories was derived.

  14. Self-Interaction Chromatography of mAbs: Accurate Measurement of Dead Volumes.

    Science.gov (United States)

    Hedberg, S H M; Heng, J Y Y; Williams, D R; Liddell, J M

    2015-12-01

    Measurement of the second virial coefficient B22 for proteins using self-interaction chromatography (SIC) is becoming an increasingly important technique for studying their solution behaviour. In common with all physicochemical chromatographic methods, measuring the dead volume of the SIC packed column is crucial for accurate retention data; this paper examines best practise for dead volume determination. SIC type experiments using catalase, BSA, lysozyme and a mAb as model systems are reported, as well as a number of dead column measurements. It was observed that lysozyme and mAb interacted specifically with Toyopearl AF-Formyl dead columns depending upon pH and [NaCl], invalidating their dead volume usage. Toyopearl AF-Amino packed dead columns showed no such problems and acted as suitable dead columns without any solution condition dependency. Dead volume determinations using dextran MW standards with protein immobilised SIC columns provided dead volume estimates close to those obtained using Toyopearl AF-Amino dead columns. It is concluded that specific interactions between proteins, including mAbs, and select SIC support phases can compromise the use of some standard approaches for estimating the dead volume of SIC columns. Two other methods were shown to provide good estimates for the dead volume.

  15. Stereoselective determination of unchanged and glucuroconjugated eliprodil, a new anti-ischaemic drug, in human plasma and urine by precolumn derivatization and column-switching high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Malavasi, B; Ripamonti, M; Rouchouse, A; Ascalone, V

    1996-04-05

    An HPLC method was developed and validated for the determination in human plasma and urine of the enantiomers of eliprodil, (+/-)-alpha-(4-chlorophenyl)-4[(4-fluorophenyl) methyl]piperidine-1-ethanol hydrochloride, a new anti-ischaemic agent administered as a racemate. Both enantiomers are present in human plasma in unchanged and glucuroconjugated form, whereas only the glucuroconjugated form is excreted into urine; as a consequence, such metabolites in human plasma and urine should be submitted to enzymatic deconjugation with beta-glucuronidase (Escherichia coli) before being extracted. The general method involves a liquid-liquid extraction of eliprodil and internal standard from alkalinized plasma or urine with n-hexane, evaporation of the organic phase and derivatization with (S)-(+)-naphthylethyl isocyanate to give carbamate diastereoisomeric derivatives of (S)-(+)- and (R)-(-)-eliprodil and internal standard; after evaporation of the derivatizing mixture and dissolution of the residue in a small volume of phosphate buffer-acetonitrile (60:40, v/v), an aliquot is injected into a column-switching HPLC system. The derivatized sample extract is purified on a precolumn filled with C8-bonded silica material, which is flushed with acetonitrile-water, then diastereoisomers of eliprodil and the internal standard are automatically transferred by the mobile phase to the analytical column. The analytical column is a C8 type, specially deactivated for basic compounds, the mobile phase is 0.025 M phosphate buffer (pH 2.6)-methanol-acetonitrile (42:2:56) at a flow-rate of 1.2 ml min-1 and fluorimetric detector operating at lambda ex = 275 nm and lambda em = 336 nm is used. The retention times, under these conditions, are about 16 and 17 min for (S)-(+)- and (R)-(-)-eliprodil diastereoisomers, respectively, and about 19 min for the first-eluted diastereoisomer of the internal standard. During the analysis time, the precolumn, reset in a different path from that of the

  16. Method of analysis of a selected group of pyrethroids in soil samples using off-line flow-through extraction and on-column direct large-volume injection in reversed phase high performance liquid chromatography.

    Science.gov (United States)

    Chalányová, Mária; Paulechová, Martina; Hutta, Milan

    2006-09-01

    An analytical method using flow-through extraction of a soil sample filled in a short HPLC column with methanol or methanol-water mixtures and large-volume injection in RP-HPLC has been developed for the simultaneous determination of residues of three pyrethroids--kadethrin, cypermethrin, and permethrin--from soil samples. The developed RP-HPLC method enables separation of four diastereoisomers of cypermethrin into three peaks and resolution of two diastereoisomers of permethrin. The UV photometric detection limits of direct on-column large-volume injection of 1.00 mL of extract were 30 ng/mL of kadethrin, 37 ng/mL of total content of cypermethrin, and 65 ng/mL of trans-permethrin, which corresponds to a pyrethroid soil content of around 0.3 mg/kg. Effects of extractant flow rate and optimal extractant volume on the percentage recovery of pyrethroids from Slovak soil samples were studied. Recovery studies were performed at 0.5- 5.0 microg/g fortification level of kadethrin and 1.0-2.5 microg/g fortification level of cypermethrin and permethrin in a soil sample. Recoveries ranged from 83 to 90% for kadethrin, from 87 to 94% for total cypermethrin, and from 85 to 98% for trans-permethrin. This work comprises a basic study aimed at elaboration of an RP-HPLC method of direct analysis of pyrethroids in a soil matrix at low concentration levels achieved by a "solid sample injection" in HPLC--on-line interfacing of analyte extraction, extract clean-up, and analysis.

  17. Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones.

    Science.gov (United States)

    Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S

    2017-09-01

    A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Contributions to reversed-phase column selectivity: III. Column hydrogen-bond basicity.

    Science.gov (United States)

    Carr, P W; Dolan, J W; Dorsey, J G; Snyder, L R; Kirkland, J J

    2015-05-22

    Column selectivity in reversed-phase chromatography (RPC) can be described in terms of the hydrophobic-subtraction model, which recognizes five solute-column interactions that together determine solute retention and column selectivity: hydrophobic, steric, hydrogen bonding of an acceptor solute (i.e., a hydrogen-bond base) by a stationary-phase donor group (i.e., a silanol), hydrogen bonding of a donor solute (e.g., a carboxylic acid) by a stationary-phase acceptor group, and ionic. Of these five interactions, hydrogen bonding between donor solutes (acids) and stationary-phase acceptor groups is the least well understood; the present study aims at resolving this uncertainty, so far as possible. Previous work suggests that there are three distinct stationary-phase sites for hydrogen-bond interaction with carboxylic acids, which we will refer to as column basicity I, II, and III. All RPC columns exhibit a selective retention of carboxylic acids (column basicity I) in varying degree. This now appears to involve an interaction of the solute with a pair of vicinal silanols in the stationary phase. For some type-A columns, an additional basic site (column basicity II) is similar to that for column basicity I in primarily affecting the retention of carboxylic acids. The latter site appears to be associated with metal contamination of the silica. Finally, for embedded-polar-group (EPG) columns, the polar group can serve as a proton acceptor (column basicity III) for acids, phenols, and other donor solutes. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Affinity monolith chromatography: A review of general principles and applications.

    Science.gov (United States)

    Li, Zhao; Rodriguez, Elliott; Azaria, Shiden; Pekarek, Allegra; Hage, David S

    2017-11-01

    Affinity monolith chromatography, or AMC, is a liquid chromatographic method in which the support is a monolith and the stationary phase is a biological-binding agent or related mimic. AMC has become popular for the isolation of biochemicals, for the measurement of various analytes, and for studying biological interactions. This review will examine the principles and applications of AMC. The materials that have been used to prepare AMC columns will be discussed, which have included various organic polymers, silica, agarose, and cryogels. Immobilization schemes that have been used in AMC will also be considered. Various binding agents and applications that have been reported for AMC will then be described. These applications will include the use of AMC for bioaffinity chromatography, immunoaffinity chromatography, dye-ligand affinity chromatography, and immobilized metal-ion affinity chromatography. The use of AMC with chiral stationary phases and as a tool to characterize biological interactions will also be examined. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Ultrafast UPLC-ESI-MS and HPLC with monolithic column for determination of principal flavor compounds in vanilla pods.

    Science.gov (United States)

    Sharma, Upendra K; Sharma, Nandini; Sinha, Arun K; Kumar, Neeraj; Gupta, Ajai P

    2009-10-01

    In this study, two novel chromatographic methods based on monolithic column high-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were developed for the ultrafast determination of principal flavor compounds namely vanillin, vanillic acid, p-hydroxybenzoic acid, and p-hydroxybenzaldehyde in ethanolic extracts of Vanilla planifolia pods. Good separation was achieved within 2.5 min using Chromolith RP18e column (100 mm x 4.6 mm) for HPLC and Acquity BEH C-18 (100 mm x 2.1 mm, 1.7 microm) column for UPLC. Both methods were compared in terms of total analysis time, mobile phase consumption, sensitivity, and validation parameters like precision, accuracy, LOD, and LOQ. Further, system suitability test data including resolution, capacity factor, theoretical plates, and tailing factor was determined for both the methods by ten replicate injections. Monolithic column based HPLC gave better results for most of the selected parameters while UPLC was found to be more eco-friendly with low mobile phase consumption and better sensitivity. Both methods may be used conveniently for the high throughput analysis of large number of samples in comparison to traditional particulate column.

  1. Fully automated multidimensional reversed-phase liquid chromatography with tandem anion/cation exchange columns for simultaneous global endogenous tyrosine nitration detection, integral membrane protein characterization, and quantitative proteomics mapping in cerebral infarcts.

    Science.gov (United States)

    Quan, Quan; Szeto, Samuel S W; Law, Henry C H; Zhang, Zaijun; Wang, Yuqiang; Chu, Ivan K

    2015-10-06

    Protein tyrosine nitration (PTN) is a signature hallmark of radical-induced nitrative stress in a wide range of pathophysiological conditions, with naturally occurring abundances at substoichiometric levels. In this present study, a fully automated four-dimensional platform, consisting of high-/low-pH reversed-phase dimensions with two additional complementary, strong anion (SAX) and cation exchange (SCX), chromatographic separation stages inserted in tandem, was implemented for the simultaneous mapping of endogenous nitrated tyrosine-containing peptides within the global proteomic context of a Macaca fascicularis cerebral ischemic stroke model. This integrated RP-SA(C)X-RP platform was initially benchmarked through proteomic analyses of Saccharomyces cerevisiae, revealing extended proteome and protein coverage. A total of 27 144 unique peptides from 3684 nonredundant proteins [1% global false discovery rate (FDR)] were identified from M. fascicularis cerebral cortex tissue. The inclusion of the S(A/C)X columns contributed to the increased detection of acidic, hydrophilic, and hydrophobic peptide populations; these separation features enabled the concomitant identification of 127 endogenous nitrated peptides and 137 transmembrane domain-containing peptides corresponding to integral membrane proteins, without the need for specific targeted enrichment strategies. The enhanced diversity of the peptide inventory obtained from the RP-SA(C)X-RP platform also improved analytical confidence in isobaric tags for relative and absolute quantitation (iTRAQ)-based proteomic analyses.

  2. Ionic liquids monolithic columns for protein separation in capillary electrochromatography.

    Science.gov (United States)

    Liu, Cui-Cui; Deng, Qi-Liang; Fang, Guo-Zhen; Liu, Hui-Lin; Wu, Jian-Hua; Pan, Ming-Fei; Wang, Shuo

    2013-12-04

    A series of ionic liquids (ILs) monolithic capillary columns based on 1-vinyl-3-octylimidazolium (ViOcIm(+)) were prepared by two approaches ("one-pot" approach and "anion-exchange" approach). The effects of different anions (bromide, Br(-); tetrafluoroborate, BF4(-); hexafluorophosphate, PF6(-); and bis-trifluoromethanesulfonylimide, NTf2(-)) on chromatography performance of all the resulting columns were investigated systematically under capillary electrochromatography (CEC) mode. The results indicated that all these columns could generate a stable reversed electroosmotic flow (EOF) over a wide pH range from 2.0 to 12.0. For the columns prepared by "one-pot" approach, the EOF decreased in the order of ViOcIm(+)Br(-)>ViOcIm(+)BF4(-)>ViOcIm(+)PF6(-)>ViOcIm(+)NTf2(-) under the same CEC conditions; the ViOcIm(+)Br(-) based column exhibited highest column efficiencies for the test small molecules; the ViOcIm(+)NTf2(-) based column possessed the strongest retention for aromatic hydrocarbons; and baseline separation of four standard proteins was achieved on ViOcIm(+)NTf2(-) based column corresponding to the highest column efficiency of 479,000 N m(-1) for cytochrome c (Cyt c). These results indicated that the property of ILs based columns could be tuned successfully by changing anions, which gave these columns potential to separate both small molecules and macro biomolecules. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  3. Effect of pioglitazone on various parameters of insulin resistance including lipoprotein subclass according to particle size by a gel-permeation high-performance liquid chromatography in newly diagnosed patients with type 2 diabetes.

    Science.gov (United States)

    Nakano, Koji; Hasegawa, Goji; Fukui, Michiaki; Yamasaki, Masahiro; Ishihara, Kiyoshi; Takashima, Tooru; Kitagawa, Yoshihiro; Fujinami, Aya; Ohta, Mitsuhiro; Hara, Hirokazu; Adachi, Tetsuo; Ogata, Masakazu; Obayashi, Hiroshi; Nakamura, Naoto

    2010-01-01

    Pioglitazone is an insulin-sensitizing agent that has been reported to have anti-arteriosclerotic effects. The aim of this study was to obtain a better understanding of the mechanism involved in the insulin sensitizing effect of pioglitazone. A total of 50 newly diagnosed patients with type 2 diabetes were enrolled in this study and divided into two groups, 25 of who were treated with 15 mg/day pioglitazone and 25 with 500 mg/day metformin for 12 weeks. Changes in various parameters of insulin resistance including lipoprotein subclass according to particle size determined by high performance liquid chromatography, as well as glucose metabolism, were monitored to determine the relationship between lipoprotein subclass and other insulin resistance parameters. Both pioglitazone and metformin treatment were associated with significant reductions in hyperglycemia, HOMA-IR and HbA1c levels. Pioglitazone treatment, but not metformin treatment resulted in significant reductions in serum large very low-density lipoprotein (VLDL: 44.5-64.0 nm) and increases in serum adiponectin levels (both net electronegative charged modified-LDL (r=0.412, P=0.0399), and inversely with changes in adiponectin level (r=-0.526, P=0.0061). The results in this study suggest that the hypoglycemic effect of pioglitazone is achieved mainly through improvement of hepatic insulin resistance, and that pioglitazone may have an antiatherosclerotic effect by decreasing serum atherogenic modified-LDL and by increasing adiponectin.

  4. Impact of energy-related pollutants on chromosome structure. Progress report, January 1-December 31, 1980. IQUID COLUMN CHROMATOGRAPHY; ABSORPTION SPECTRA; COMPUTER CODES; DICHROISM; EQUIPMENT INTERFACES; MICROPROCESSORS; SPECTROPHOTOMETERS; ; CARBON 13; COMPLEXES; NUCLEAR MAGNETIC RESONANCE

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    Methods for rapidly analyzing methylated and ethylated nucleosides and bases by high pressure liquid chromatography were investigated. Deoxyribonucleotides were alkylated with alkyl iodides and dialkyl sulfates. Several unreported products of the reactions of methyl and ethyl iodide in dimethylsulfoxide were found and are being characterized. The Cary 219 UV-Vis spectrophotometer was interfaced to a microcomputer and several utility programs were written. Preliminary absorption and circular dichroism studies of the binding of ethidium to DNA and nucleosome cores showed binding to cores to be quite different from binding to DNA. Free radical and additional reactions of bisulfite with DNA in chromatin were examined. Free radical attack was minimal. Some conversion of cytosine to uracil was noted, but protein crosslinking to DNA was not detected. The first valid natural abundance /sup 13/C nmr spectra of double-stranded DNA and double-stranded DNA complexed with ethidium were obtained. These spectra suggested that DNA undergoes considerable internal motion. The data show that 13-C nmr studies of the conformational and motional properties of native DNA and of complexes of native DNA with small molecules are practical and promising. Studies of subnucleosomes derived from nucleosomes were completed. Based on these studies, a model of the linear arrangement of histone C-terminal and N-terminal chain regions along nucleosome DNA was proposed. The use of staphylococcal protease to probe histone conformations in nucleosomes was explored. Preliminary data indicate that H3 is much more susceptible to protease than other core histones, and is cleaved in its hydrophobic domain. A procedure for fractionating chromatin was alos developed. (ERB)

  5. Recent Advances and Uses of Monolithic Columns for the Analysis of Residues and Contaminants in Food

    Directory of Open Access Journals (Sweden)

    Mónica Díaz-Bao

    2015-02-01

    Full Text Available Monolithic columns are gaining interest as excellent substitutes to conventional particle-packed columns. These columns show higher permeability and lower flow resistance than conventional liquid chromatography columns, providing high-throughput performance, resolution and separation in short run times. Monoliths possess also great potential for the clean-up and preparation of complex mixtures. In situ polymerization inside appropriate supports allows the development of several microextraction formats, such as in-tube solid-phase and pipette tip-based extractions. These techniques using porous monoliths offer several advantages, including miniaturization and on-line coupling with analytical instruments. Additionally, monoliths are ideal support media for imprinting template-specific sites, resulting in the so-called molecularly-imprinted monoliths, with ultra-high selectivity. In this review, time-saving LC columns and preparative applications applied to the analysis of residues and contaminants in food in 2010–2014 are described, focusing on recent improvements in design and with emphasis in automated on-line systems and innovative materials and formats.

  6. Gas Chromatography.

    Science.gov (United States)

    Cram, Stuart P.; And Others

    1980-01-01

    Selects fundamental developments in theory, methodology, and instrumentation in gas chromatography (GC). A special section reviews GC in the People's Republic of China. Over 1,000 references are cited. (CS)

  7. Electrochemically modulated liquid chromatography: Theoretical investigations and applications from the perspectives of chromatography and interfacial electrochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Keller, David W. [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    Electrochemically modulated liquid chromatography (EMLC) employs a conductive material as both a stationary phase for chromatographic separations and as a working electrode for performing electrochemistry experiments. This dual functionality gives EMLC the capacity to manipulate chromatographic separations by changing the potential applied (Eapp) to the stationary phase with respect to an external reference. The ability to monitor retention as a function of Eapp provides a means to chromatographically monitor electrosorption processes at solid-liquid interfaces. In this dissertation, the retention mechanism for EMLC is examined from the perspective of electrical double layer theory and interfacial thermodynamics. From the chromatographic data, it is possible to determine the interfacial excess (Λ) of a solute and changes in interfacial tension (dγ) as a function of both Eapp and the supporting electrolyte concentration. Taken together, these two experimentally manipulated parameters can be examined within the context of the Gibbs adsorption equation to delineate the contribution of a variety of interfacial properties, including the charge of solute on the stationary phase and the potential of zero charge (PZC), to the mechanism behind EMLC-based retention. The chromatographic probing of interfacial phenomena is complemented by electroanalytical experiments that exploit the ability to monitor the electronic current flowing through an EMLC column. Cyclic voltammetry and chronoamperometry of an EMLC column are used to determine the electronic performance characteristics of an EMLC column. An electrochemical flow injection analysis of a column is provided in which the current required to maintain a constant Eapp is monitored and provides a way to examine the influence that acetonitrile and supporting electrolyte composition, flow rate, column backpressure, and ionic strength have on the structure of electrified interfaces.

  8. Continuous countercurrent tangential chromatography for mixed mode post-capture operations in monoclonal antibody purification.

    Science.gov (United States)

    Dutta, Amit K; Fedorenko, Dmitriy; Tan, Jasmine; Costanzo, Joseph A; Kahn, David S; Zydney, Andrew L; Shinkazh, Oleg

    2017-08-18

    Continuous Countercurrent Tangential Chromatography (CCTC) has been shown to demonstrate significant advantages over column chromatography including higher productivity, lower operational pressure, disposable flow path, and lower resin use. Previous applications of CCTC have been limited to initial capture of monoclonal antibodies (mAb) from clarified cell culture harvest. In this present article, a CCTC system was designed and tested for a post-capture antibody purification step. Mixed mode cation exchange-hydrophobic interaction chromatography resins with two different particle sizes were used to reduce host cell protein (HCP), leached protein A, DNA, and aggregates from a mAb stream after a protein A operation. Product output from CCTC was obtained at a steady-state concentration in sharp contrast to the periodic output of product in multi-column systems. The results show up to 101g of mAb/L of resin/hr productivity, which is 10× higher than in a batch column. A 5% yield increase (95% with CCTC vs. 90% in batch column) resulted from optimizing elution pH within a narrow operational window (pH 4-4.5). Contaminant removal was found to be similar to conventional column performance. Data obtained with the smaller particle size resin showed faster binding kinetics leading to reduced CCTC system volume and increased productivity. Buffer and water usage were modeled to show potential for utilization of in-line mixing and buffer tank volume reduction. The experimental results were used to perform a scale up exercise that predicts a compact CCTC flow path for 500 and 2000L batches using commercially available membranes. These results demonstrate the potential of using CCTC for post-capture operations as an alternative to packed bed chromatography, and provide a framework for the design and development of an integrated continuous bioprocessing platform based on CCTC technology. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Distillation Column Flooding Predictor

    Energy Technology Data Exchange (ETDEWEB)

    George E. Dzyacky

    2010-11-23

    The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillation columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid

  10. Nuclear reactor control column

    International Nuclear Information System (INIS)

    Bachovchin, D.M.

    1982-01-01

    The nuclear reactor control column comprises a column disposed within the nuclear reactor core having a variable cross-section hollow channel and containing balls whose vertical location is determined by the flow of the reactor coolant through the column. The control column is divided into three basic sections wherein each of the sections has a different cross-sectional area. The uppermost section of the control column has the greatest crosssectional area, the intermediate section of the control column has the smallest cross-sectional area, and the lowermost section of the control column has the intermediate cross-sectional area. In this manner, the area of the uppermost section can be established such that when the reactor coolant is flowing under normal conditions therethrough, the absorber balls will be lifted and suspended in a fluidized bed manner in the upper section. However, when the reactor coolant flow falls below a predetermined value, the absorber balls will fall through the intermediate section and into the lowermost section, thereby reducing the reactivity of the reactor core and shutting down the reactor

  11. [Preparation of a reversed-phase capillary monolithic column and its application in the separation of polypeptide mixtures].

    Science.gov (United States)

    Xie, Jingxin; Bi, Kaishun; Qian, Xiaohong; Zuang, Yangiun

    2009-03-01

    Capillary monolithic columns (75 microm i.d.) were prepared by the copolymerization of lauryl methacrylate as the basic monomer, ethylene dimethacrylate as the cross-linking agent and 1-dodecyl alcohol, 1,4-butanediol and dimethyl sulfoxide as the porogenic mixture. The synthetic stationary phases had better mechanical properties and chemical stabilities. A series of characterization and evaluations were performed on the capillary monolithic columns including the scanning electron microscope (SEM) images, the influences of pressure and the effects on the separation of peptide mixtures by changing the proportions of the porogen solution and cross-linking agent. The final prescription ciontained 15% (w/w) monomer, 15% (w/ w) cross-linking agent, and 70% (w/w) porogenic agent. Then the solution was heated at 70 1C for 24 h. The test of relationship between column length and back pressure showed that the capillary monolithic columns prepared have superior permeability, so a longer column can be used to improve the effects of separation. The prepared capillary monolithic columns are fitted on the nano-scale high performance liquid chromatography for the separation of tryptic digests of bovine serum albumin (BSA) and human plasma samples, and better results have been obtained.

  12. Counter-current motion in counter-current chromatography.

    Science.gov (United States)

    Ito, Yoichiro

    2014-12-12

    After the CCC2012 meeting, I have received an e-mail regarding the terminology of "Countercurrent Chromatography". It stated that the term "Countercurrent" is a misnomer, because its stationary phase is motionless in the column and that the method should be renamed as liquid-liquid separations or centrifugal separations. However, it was found that these names are already used for various other techniques as found via Google search. The term "Countercurrent Chromatography" was originally made after two preparative methods of Countercurrent distribution and liquid Chromatography, both having no countercurrent motion in the column. However, it is surprising to find that this F1 hybrid method "Countercurrent Chromatography" can clearly exhibit countercurrent motion within the separation column in both hydrodynamic and hydrostatic equilibrium systems. This justifies that "Countercurrent Chromatography" is a proper term for this chromatographic method. Published by Elsevier B.V.

  13. Buckling of liquid columns

    NARCIS (Netherlands)

    Habibi, M.; Rahmani, Y.; Bonn, D.; Ribe, N.M.

    2010-01-01

    Under appropriate conditions, a column of viscous liquid falling onto a rigid surface undergoes a buckling instability. Here we show experimentally and theoretically that liquid buckling exhibits a hitherto unsuspected complexity involving three different modes—viscous, gravitational, and

  14. Fast temperature programming in gas chromatography using resistive heating

    NARCIS (Netherlands)

    Dallüge, J.; Ou-Aissa, R.; Vreuls, J.J.; Brinkman, U.A.T.; Veraart, J.R.

    1999-01-01

    The features of a resistive-heated capillary column for fast temperature-programmed gas chromatography (GC) have been evaluated. Experiments were carried out using a commercial available EZ Flash GC, an assembly which can be used to upgrade existing gas chromatographs. The capillary column is placed

  15. Analytical chromatography. Methods, instrumentation and applications

    International Nuclear Information System (INIS)

    Yashin, Ya I; Yashin, A Ya

    2006-01-01

    The state-of-the-art and the prospects in the development of main methods of analytical chromatography, viz., gas, high performance liquid and ion chromatographic techniques, are characterised. Achievements of the past 10-15 years in the theory and general methodology of chromatography and also in the development of new sorbents, columns and chromatographic instruments are outlined. The use of chromatography in the environmental control, biology, medicine, pharmaceutics, and also for monitoring the quality of foodstuffs and products of chemical, petrochemical and gas industries, etc. is considered.

  16. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    Science.gov (United States)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better

  17. Cyclodextrin-Functionalized Monolithic Capillary Columns: Preparation and Chiral Applications.

    Science.gov (United States)

    Adly, Frady G; Antwi, Nana Yaa; Ghanem, Ashraf

    2016-02-01

    In this review, the recently reported approaches for the preparation of cyclodextrin-functionalized capillary monolithic columns are highlighted, with few applications in chiral separations using capillary liquid chromatography (CLC) and capillary electrochromatography (CEC). Chirality 28:97-109, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  18. Applications of monolithic silica capillary columns in proteomics

    NARCIS (Netherlands)

    Barroso, B.; Lubda, D; Bischoff, Rainer

    2003-01-01

    The use and applicability of silica based capillary monolithic reversed-phase columns in proteomic analysis has been evaluated by liquid chromatography-mass spectrometry (LC-MS). Chromatographic performance of the monolithic capillaries was evaluated with a tryptic digest of cytochrome C showing

  19. Monolithic and Small Particle Column Materials for Application in Proteomics

    NARCIS (Netherlands)

    Rozenbrand, J.

    2012-01-01

    In this thesis the influence of the capillary liquid chromatography separation on the identification of protein digests is studied. In the first part the chromatographic parameters for silica monolithic columns are optimized to obtain a high throughput or a high separation performance. in the second

  20. Pseudo-affinity chromatography of rumen microbial cellulase on ...

    African Journals Online (AJOL)

    Pseudo-affinity chromatography of rumen microbial cellulase on Sepharose- Cibacron Blue F3GA. ... African Journal of Biotechnology ... Pseudo affinity adsorption of bioproducts on Sepharose-cibacron blue F3-GA was subjected to rumen microbial enzyme evaluation through batch binding and column chromatography of ...