WorldWideScience

Sample records for incision repair nir

  1. Tubularized incised plate urethroplasty repair in adult hypospadias ...

    African Journals Online (AJOL)

    Objective: Most studies published in the literature report on the results of tubularized incised plate urethroplasty (TIPU) for hypospadias repair in children. Hence, the objective of this study was to evaluate the results of TIPU repair in adults. Patients and methods: The records of 60 adult patients with primary hypospadias ...

  2. Incision Coordination in Nucleotide Excision Repair

    NARCIS (Netherlands)

    W.L. de Laat (Wouter)

    1998-01-01

    textabstractThis thesis aims to contribute to the understanding of the molecular mechanism that underlies one of the main DNA repair pathways in mammals, nucleotide excision rcpair. In chapter 1 the relevance of DNA repair in general is outlined. An overview of mammalian strategies to counteract DNA

  3. Small incision transcutaneous levator aponeurotic repair for blepharoptosis.

    Science.gov (United States)

    Baroody, Michael; Holds, John B; Sakamoto, Douglas K; Vick, Valerie L; Hartstein, Morris E

    2004-06-01

    Patients presenting with blepharoptosis due to disinsertion or thinning of the levator aponeurosis require surgical repair. A minimally invasive approach directed specifically at the levator aponeurotic anatomic defect may provide benefits to the patient. Proposed advantages of a small eyelid incision (8-13 mm) include less local anesthetic and tissue distortion, less ecchymosis and edema, decreased operative times, a shortened recovery period, and improved surgical results. We describe our results with the use of a small incision ptosis repair in select patients. A retrospective chart review between January 2000 and September 2001 included 91 patients and 118 eyelids with blepharoptosis due to aponeurotic disinsertion, corrected by a minimally invasive approach. The small incision technique comprised levator aponeurotic resection and advancement. Pre- and postoperative upper eyelid marginal reflex distances (MRD1), eyelid contour, need for reoperation, and complications (overcorrection, undercorrection, hematoma, and infection) were recorded. The average preoperative MRD1 measured 0.5 +/- 1.1 mm, with a range of -2.0 to 2.5 mm. The average postoperative MRD1 measured 2.6 +/- 0.8 mm, with a range of 1 to 5.5 mm (P < 0.0001). Of the 118 eyelids corrected by a small incision technique, there were 4 overcorrections, 3 undercorrections, 1 failure, 1 postoperative ptosis procedure of the contralateral upper eyelid secondary to Hering's law ptosis, and 4 patients requesting surgical treatment of dermatochalasis. No symptomatic dry eye, exposure keratopathy, or other complication resulted in association with the overcorrections. No contour abnormalities, infections, hematomas, or other complications were noted. Our experience suggests that utilization of a small skin incision is safe, precise, and efficient and allows for more rapid recovery from surgery. The authors note a decreased incidence of reoperation and postoperative complaints compared with historical larger-incision

  4. Highly mutagenic exocyclic DNA adducts are substrates for the human nucleotide incision repair pathway.

    Directory of Open Access Journals (Sweden)

    Paulina Prorok

    Full Text Available BACKGROUND: Oxygen free radicals induce lipid peroxidation (LPO that damages and breaks polyunsaturated fatty acids in cell membranes. LPO-derived aldehydes and hydroxyalkenals react with DNA leading to the formation of etheno(ε-bases including 1,N(6-ethenoadenine (εA and 3,N(4-ethenocytosine (εC. The εA and εC residues are highly mutagenic in mammalian cells and eliminated in the base excision repair (BER pathway and/or by AlkB family proteins in the direct damage reversal process. BER initiated by DNA glycosylases is thought to be the major pathway for the removal of non-bulky endogenous base damage. Alternatively, in the nucleotide incision repair (NIR pathway, the apurinic/apyrimidinic (AP endonucleases can directly incise DNA duplex 5' to a damaged base in a DNA glycosylase-independent manner. METHODOLOGY/PRINCIPAL FINDINGS: Here we have characterized the substrate specificity of human major AP endonuclease 1, APE1, towards εA, εC, thymine glycol (Tg and 7,8-dihydro-8-oxoguanine (8oxoG residues when present in duplex DNA. APE1 cleaves oligonucleotide duplexes containing εA, εC and Tg, but not those containing 8oxoG. Activity depends strongly on sequence context. The apparent kinetic parameters of the reactions suggest that APE1 has a high affinity for DNA containing ε-bases but cleaves DNA duplexes at an extremely slow rate. Consistent with this observation, oligonucleotide duplexes containing an ε-base strongly inhibit AP site nicking activity of APE1 with IC(50 values in the range of 5-10 nM. MALDI-TOF MS analysis of the reaction products demonstrated that APE1-catalyzed cleavage of εA•T and εC•G duplexes generates, as expected, DNA fragments containing 5'-terminal ε-base residue. CONCLUSIONS/SIGNIFICANCE: The fact that ε-bases and Tg in duplex DNA are recognized and cleaved by APE1 in vitro, suggests that NIR may act as a backup pathway to BER to remove a large variety of genotoxic base lesions in human cells.

  5. A new incision for unilateral cleft lip repair developed using animated simulation of repair on computer

    Directory of Open Access Journals (Sweden)

    Sahay A

    2007-01-01

    Full Text Available Background: Unilateral cleft lip repair continues to leave behind some amount of dissatisfaction, as a scope for further improvement is always felt. Most surgeons do not like to deviate from the standard Millard′s/ triangular techniques, or their minor modifications, as no one likes to experiment on the face for fear of unfavourable outcomes. The computer can be utilized as a useful tool in the analysis and planning of surgery and new methods can be developed and attempted subsequently with greater confidence. Aim: We decided to see if an improved lip repair could be developed with the use of computers. Materials and Methods: Analysis of previous lip repairs was done to determine where an improvement was required. Movement of tissues, by simulating an ideal repair, using image warping software, on digital images of cleft lip was studied in animation sequences. A repair which could reproduce these movements was planned. A new incision emerged, which had combined the principles of Millard′s and Randall / Tennyson repairs, with additional features. The new method was performed on 30 cases. Conclusions: The results were encouraging as the shortcomings of these methods were minimized, and the advantages maximized.

  6. Single Incision Distal Biceps Repair With Hemi-Krackow Suture Technique: Surgical Technique and Early Outcomes

    OpenAIRE

    Goljan, Peter; Patel, Nimit; Stull, Justin D.; Donnelly, Brandon P.; Culp, Randall W.

    2016-01-01

    Background: Many surgical methods exist for distal biceps repair. We present the technique and early outcomes of a series of distal biceps repairs completed with a novel suturing technique utilizing a hemi-Krackow locking stitch at the tendon-bone interface. Methods: A retrospective review was performed of patients who underwent primary distal biceps repair using a single anterior incision with 2 suture anchors utilizing a hemi-Krackow stitch. With both anchors, a locking stitch along the ten...

  7. Dual daughter strand incision is processive and increases the efficiency of DNA mismatch repair.

    Science.gov (United States)

    Hermans, Nicolaas; Laffeber, Charlie; Cristovão, Michele; Artola-Borán, Mariela; Mardenborough, Yannicka; Ikpa, Pauline; Jaddoe, Aruna; Winterwerp, Herrie H K; Wyman, Claire; Jiricny, Josef; Kanaar, Roland; Friedhoff, Peter; Lebbink, Joyce H G

    2016-08-19

    DNA mismatch repair (MMR) is an evolutionarily-conserved process responsible for the repair of replication errors. In Escherichia coli, MMR is initiated by MutS and MutL, which activate MutH to incise transiently-hemimethylated GATC sites. MMR efficiency depends on the distribution of these GATC sites. To understand which molecular events determine repair efficiency, we quantitatively studied the effect of strand incision on unwinding and excision activity. The distance between mismatch and GATC site did not influence the strand incision rate, and an increase in the number of sites enhanced incision only to a minor extent. Two GATC sites were incised by the same activated MMR complex in a processive manner, with MutS, the closed form of MutL and MutH displaying different roles. Unwinding and strand excision were more efficient on a substrate with two nicks flanking the mismatch, as compared to substrates containing a single nick or two nicks on the same side of the mismatch. Introduction of multiple nicks by the human MutLα endonuclease also contributed to increased repair efficiency. Our data support a general model of prokaryotic and eukaryotic MMR in which, despite mechanistic differences, mismatch-activated complexes facilitate efficient repair by creating multiple daughter strand nicks. © The Author(s) 2016. Published by Oxford University Press on behalf of Nucleic Acids Research.

  8. In vitro conjunctival incision repair by temperature-controlled laser soldering

    Science.gov (United States)

    Norman, Galia; Rabi, Yaron; Assia, Ehud; Katzir, Abraham

    2009-11-01

    The common method of closing conjunctival incisions is by suturing, which is associated with several disadvantages. It requires skill to apply and does not always provide a watertight closure, which is required in some operations (e.g., glaucoma filtration). The purpose of the present study was to evaluate laser soldering as an alternative method for closing conjunctival incisions. Conjunctival incisions of 20 ex vivo porcine eyes were laser soldered using a temperature-controlled fiberoptic laser system and an albumin mixed with indocyanine green as a solder. The control group consisted of five repaired incisions by a 10-0 nylon running suture. The leak pressure of the repaired incisions was measured. The mean leak pressure in the laser-soldered group was 132 mm Hg compared to 4 mm Hg in the sutured group. There was no statistically significant difference in both the incision's length and distance from the limbus between the groups, before and after the procedure, indicating that there was no severe thermal damage. These preliminary results clearly demonstrate that laser soldering may be a useful method for achieving an immediate watertight conjunctival wound closure. This procedure is faster and easier to apply than suturing.

  9. Dual-incision approach for repair of peroneal tendon dislocation associated with fractures of the calcaneus.

    Science.gov (United States)

    Mak, May Fong; Tay, Guan Tzu; Stern, Richard; Assal, Mathieu

    2014-02-01

    Dislocation of the peroneal tendons associated with calcaneus fractures should be repaired during fracture fixation to prevent complications. The only documented approach for repair is by proximal extension of the vertical limb of the lateral extensile approach to the calcaneus. However, enlarging the inherently fragile calcaneus flap places it at further risk of damage. Using a separate anterior incision to repair the dislocation, thus avoiding problems caused by excessive flap elevation, seemed intuitive. This approach proved technically effective and reliable in producing favorable outcomes in a series of 14 patients. Copyright 2014, SLACK Incorporated.

  10. Comparison of Fasanella-Servat and Small-Incision Techniques for Involutional Ptosis Repair.

    Science.gov (United States)

    Sohrab, Mahsa A; Lissner, Gary S

    2016-01-01

    To compare the results of the classic Fasanella-Servat internal approach to the newer, small-incision external approach in the repair of involutional ptosis. Retrospective review identified 93 patients (104 surgical procedures) at Northwestern Ophthalmology from June 2005 until October 2011 who underwent either the Fasanella-Servat or the small-incision approaches for involutional ptosis repair. Change in vertical palpebral fissure measurement, change in marginal reflex distance 1 (MRD1) measurement, patient satisfaction, surgical complications, operating time, and postoperative pain were compared between groups. Of the 93 patients, most were female with an average age of 69 years. Of the procedures, 48% were small incision and 52% were Fasanella-Servat approaches. Average postoperative follow up was 34.0 days. Vertical palpebral fissure height increased an average of 3.36 mm (±1.15) in the Fasanella-Servat group and 2.74 mm (±1.18) in the small-incision group (p = 0.003). Preoperative vertical palpebral fissure height was lower in the Fasanella-Servat group, but postoperative vertical palpebral fissure height was similar between the 2 groups (p=0.3). MRD1 increased an average of 3.42 mm (±0.86) in the Fasanella-Servat group and 2.68 mm (±0.93) in the small-incision group (p MRD1 was lower in the Fasanella-Servat group, but postoperative MRD1 was similar between the 2 groups (p = 0.15). Average operating time was 53 minutes (±16) in the small-incision group and 27 minutes (±6) in the Fasanella-Servat group (p MRD1.

  11. Single Incision Distal Biceps Repair With Hemi-Krackow Suture Technique

    Science.gov (United States)

    Goljan, Peter; Patel, Nimit; Stull, Justin D.; Donnelly, Brandon P.; Culp, Randall W.

    2016-01-01

    Background: Many surgical methods exist for distal biceps repair. We present the technique and early outcomes of a series of distal biceps repairs completed with a novel suturing technique utilizing a hemi-Krackow locking stitch at the tendon-bone interface. Methods: A retrospective review was performed of patients who underwent primary distal biceps repair using a single anterior incision with 2 suture anchors utilizing a hemi-Krackow stitch. With both anchors, a locking stitch along the tendon edge was complimented by the other strand passing through the central aspect of the distal tendon and advanced to pull the tendon edge down to the bone with appropriate tension. Patients with revision surgery and the use of allograft were excluded. Clinical outcomes included elbow range of motion and grip strength. All patients completed a Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) questionnaire and reported satisfaction level, pain level, and any postoperative complications. Results: Fourteen patients with an average age of 51.3 years (range, 27.8-66.4 years) were included in the study. The dominant arm was injured in 9 cases. At an average of 16.4 months’ follow-up (range, 6.8-34.3 months), all patients had elbow range of motion of 0° to >130°, and grip strength was 101.5% of the uninjured arm (range, 70.6%-121.4%). The Average QuickDASH score was 6.5 (range, 0-36.5). Conclusion: Single incision biceps repair with suture anchor fixation using our hemi-Krackow stitch provided a strong repair allowing easy tensioning of the biceps tendon to bone and showed satisfactory functional outcomes at early follow-up. No patients required revision surgery, and there was only 1 case of transient nerve complaints. PMID:27390570

  12. 5-year results of the 1.5cm incision Achilles tendon repair.

    Science.gov (United States)

    Ling, Samuel K K; Slocum, Amanda; Lui, T H

    2017-12-01

    To study a hypothesis that the cost-effective 1.5cm medial incision Achilles tendon repair technique will provide good functional outcomes which are maintained for over 5 years. Prospective study of 12 consecutive cases with a minimal 5-year follow-up were recruited from April 2008 to November 2010. Cases whom were mentally incompetent or those which required concomitant procedures were excluded. Outcomes measures included the numeric pain rating scale, motor power strength, range of motion, functional scoring using the AOFAS hindfoot score and patient's self-assessment using the Foot and Ankle Outcome Score (FAOS). No re-ruptures or sural nerve injured were identified after a minimal 5-year follow-up. Pain was minimal at 0.5/10, calf power was 5/5 and ankle range was good (plantarflexion: 38°/dorsiflexion: 21°). The AOFAS hindfoot score was 97.4 and all 5 sub-categories of the Foot and Ankle Outcome Score (FAOS) were good. The 1.5cm medial incision repair of the Achilles tendon is an economically sound surgical technique, with minimal complications, which gives good medium length functional outcomes. IV. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Primary pulley enlargement in zone 2 by incision and repair with an extensor retinaculum graft.

    Science.gov (United States)

    Bunata, Robert E

    2010-05-01

    This retrospective study documents the results of primary enlargement of tendon sheath pulleys by incision and extensor retinaculum graft repair during flexor tendon repairs in zone 2 in 9 fingers. The entire A2 or A4 pulley was enlarged by complete incision and repaired with an interposed extensor retinaculum graft at the time of primary flexor tendon repair in a total of 9 fingers in 7 patients, ages 15 to 54 years. The indication for primary pulley enlargement was failure of the tendon repair to glide smoothly and without snagging through the normally tight-fitting pulley system. In no case was more than one major pulley enlarged, and the entire A1 pulley was never enlarged. The zone 2 tendon repairs were done using a 2-strand modified Kessler 3-0 core suture and a 6-0 nylon running circumferential suture. The follow-up averaged 3.6 years. Interphalangeal total active motion and Strickland-Glogovac grade in patients with adequate follow-up of more than 6 months or obtaining full range of motion were obtained from a retrospective chart review. Interphalangeal total active motion averaged 127 degrees and the scores according to the Strickland-Glogovac system were excellent for 3, good for 2, fair for 2, and poor for 2. There were no tendon ruptures. Two fingers in one patient required a tenolysis and a third finger had secondary skin scar lengthening. Two fingers had visible and palpable bowstringing when seen at long-term follow-up and there was an average flexion contracture of 21 degrees. Primary pulley enlargement using a free graft in zone 2 tendon injuries may achieve the 3 goals of providing a good gliding environment, avoiding triggering, and minimizing bowstringing. These initial clinical outcomes are average for zone 2 tendon repair, but encouraging. Further research and refinement in surgical technique and rehabilitation method are needed to minimize flexion contractures. Copyright 2010 American Society for Surgery of the Hand. Published by Elsevier Inc

  14. Minimal Incision Scar-Less Open Umbilical Hernia Repair in Adults - Technical Aspects and Short Term Results

    Directory of Open Access Journals (Sweden)

    Sanoop Koshy Zachariah

    2014-09-01

    Full Text Available Background: There is no gold standard technique for umbilical hernia repair .Conventional open umbilical hernia repair often produces an undesirable scar. Laparoscopic umbilical hernia repair requires multiple incisions beyond the umbilicus, specialized equipments, and expensive tissue separating mesh. We describe our technique of open umbilical hernia repair utilizing a small incision. The technique was derived from our experience with single incision laparoscopy. We report the technical details and short term results. Methods: This is a retrospective analysis of the first 20 patients who underwent minimal incision scar-less open umbilical hernia repair, from June 2011 to February 2014. A single intra-umbilical curved incision was used to gain access to the hernia sac. Primary suture repair was performed for defects upto 2cm.Larger defects were repaired using an onlay mesh. In patients with a BMI of 30 kg/m2 or greater, onlay mesh hernioplasty was performed irrespective of the defect size.Results: A total of 20 patients, 12 males and 8 females underwent the procedure. Mean age was 50 (range 29 - 82 years. Mean BMI was 26.27 (range 20. -33.1 kg/m2. Average size of the incision was 1.96 range (1.5 to 2.5 cm. Mesh hernioplasty was done in 9 patients. 11 patients underwent primary suture repair alone. There were no postoperative complications associated with his technique. Average post operative length of hospital stay was 3.9 (range 2-10 days. Mean follow-up was 29.94 months, (2 weeks to 2.78 years. On follow up there was no externally visible scar in any of the patients. There were no recurrences on final follow up. Conclusion: This technique provides a similar cosmetic effect as obtained from single port laparoscopy. It is easy to perform safe, offers good cosmesis, does not require incisions beyond the umbilicus and cost effective, with encouraging results on short term follow up. Further research is needed to assess the true potential of the

  15. Acute Achilles tendon rupture: Mini-incision repair with double-Tsuge loop suture vs. open repair with modified Kessler suture.

    Science.gov (United States)

    Fu, Chongyang; Qu, Wei

    2015-08-01

    Achilles tendon rupture is a common injury of the foot and ankle. However, the optimal treatment strategy for Achilles tendon rupture is still not established. This study was conducted to compare the efficacy and complications of mini-incision repair with double-Tsuge loop sutures and open repair with modified Kessler sutures. We evaluated data from 60 patients with acute closed Achilles tendon ruptures who underwent mini-incision repair with double-Tsuge loop sutures (n = 30) or open repair with modified Kessler sutures (n = 30) from 2006 to 2010 in an ongoing prospective study conducted by us and have finished at least 18-month follow-up or finished the study. The AOFAS Ankle-Hindfoot score, ATRS, maximal ankle range of motion and the time to achieve 20 continuous single heel raises after operation were recorded to compare the efficacy. The complications were also evaluated. During a mean follow-up of 25 months after surgery, the time to achieve 20 continuous single heel raises after operation of patients in Group Mini was significantly shorter than patients in Group Open. Moreover, the mini-incision with double-Tsuge repair was associated with a significantly shorter operating time, smaller incision length, and lower rate of complications. The mini-incision with double-Tsuge suture method in our study was shown to provide earlier strength recovery, as well as shorter operation time, less complications and improved cosmetic appearance. Copyright © 2014 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  16. Lys98 substitution in human AP endonuclease 1 affects the kinetic mechanism of enzyme action in base excision and nucleotide incision repair pathways.

    Directory of Open Access Journals (Sweden)

    Nadezhda A Timofeyeva

    Full Text Available Human apurinic/apyrimidinic endonuclease 1 (APE1 is a key enzyme in the base excision repair (BER and nucleotide incision repair (NIR pathways. We recently analyzed the conformational dynamics and kinetic mechanism of wild-type (wt protein, in a stopped-flow fluorescence study. In this study, we investigated the mutant enzyme APE1K98A using the same approach. Lys98 was known to hydrogen bond to the carboxyl group of Asp70, a residue implicated in binding the divalent metal ion. Our data suggested that the conformational selection and induced fit occur during the enzyme action. We expanded upon the evidence that APE1 can pre-exist in two conformations. The isomerization of an enzyme-product complex in the BER process and the additional isomerization stage of enzyme-substrate complex in the NIR process were established for APE1K98A. These stages had not been registered for the wtAPE1. We found that the K98A substitution resulted in a 12-fold reduction of catalytic constant of 5'-phosphodiester bond hydrolysis in (3-hydroxytetrahydrofuran-2-ylmethyl phosphate (F, tetrahydrofuran containing substrate, and in 200-fold reduction in 5,6-dihydrouridine (DHU containing substrate. Thus, the K98A substitution influenced NIR more than BER. We demonstrated that the K98A mutation influenced the formation of primary unspecific enzyme-substrate complex in a complicated manner, depending on the Mg(2+ concentration and pH. This mutation obstructed the induced fit of enzyme in the complex with undamaged DNA and F-containing DNA and appreciably decreased the stability of primary complex upon interaction of enzyme with DNA, containing the natural apurinic/apyrimidinic (AP site. Furthermore, it significantly delayed the activation of the less active form of enzyme during NIR and slowed down the conformational conversion of the complex of enzyme with the cleavage product of DHU-substrate. Our data revealed that APE1 uses the same active site to catalyze the cleavage

  17. Blepharoptosis repair through the small orbital septum incision and minimal dissection technique in patients with coexisting dermatochalasis.

    Science.gov (United States)

    Jung, Younhea; La, Tae Yoon

    2013-02-01

    To describe a modified surgical technique for blepharoptosis repair through a small orbital septum incision and minimal dissection, along with the results obtained in patients with coexisting dermatochalasis. A retrospective chart review included 33 patients (52 eyelids) with blepharoptosis coexisting with dermatochalasis, surgically corrected through a small orbital septum incision and minimal dissection after redundant upper lid skin excision, by placing a single fixation suture between the levator aponeurosis and the tarsal plate. Outcome measures included the pre- and postoperative marginal reflex distances (MRD1), eyelid contour, post-operative complications, and need for reoperation. The pre- and postoperative MRD1 averaged 1.1 ± 0.8 mm and 2.8 ± 1.1 mm, respectively. Of the 33 patients, 9 patients (9 eyelids) underwent surgery on one eyelid for unilateral blepharoptosis and dermatochalasis (Group I), 5 patients (5 eyelids) underwent a simple skin excision blepharoplasty of the contralateral eyelid (Group II), and 19 patients (38 eyelids) underwent bilateral blepharoptosis and dermatochalasis repair (Group III). Of the 14 eyelids that underwent unilateral ptosis repair (Groups I and II), 12 eyelids (85.7%) showed less than a 1-mm difference from the contralateral eyelid. Of the 38 eyelids that underwent bilateral ptosis repair (Group III), 27 eyelids (71.1%), 5 eyelids (13.1%), and 6 eyelids (15.8%) had excellent, good, and poor outcomes, respectively. Overall, 44 eyelids (84.6%) out of a total of 52 eyelids had successful outcomes; the remaining 8 eyelids demonstrated unsatisfactory eyelid contour was corrected by an additional surgery. Blepharoptosis repair through a small orbital septum incision and minimal dissection can be considered an efficient technique in patients with ptosis and dermatochalasis.

  18. Vaginal mesh repair SYSTEMS for pelvic organ prolapse: Anatomical study comparing transobturator/trangluteal versus single incision techniques.

    Science.gov (United States)

    Campagna, Giuseppe; Panico, Giovanni; Morciano, Andrea; Gadonneix, Pierre; Delmas, Vincent; Cervigni, Mauro; Ercoli, Alfredo; Scambia, Giovanni

    2017-09-18

    The present study aim to compare the anatomic landmarks of two pelvic floor repair systems, in order to identify the potential neurovascular lesions related to different mesh fixation techniques. Abdominal and perineal dissections of 10 fresh cadavers after prolapse surgery using transobturator/transgluteal versus single incision techniques. Neuro-vascular structures of obturator region and perineum were isolated. Distances between needles and anatomical structures were measured. During transobturator anterior repair, the superficial cannula passed 2.5 ± 0.6 cm medially to the obturator canal. The distance of superficial arm to the anterior obturator vessels was 2.2 ± 0.4 cm. The distance of deep cannula to the posterior obturator vessels branches was 1.3 ± 0.5 cm. In two of these cases we observed a lesion of posterior obturator vessels. During single incision repair the distance between the obturator canal and the superficial arms was 2.3 ± 0.7. The mean distances of superficial arms to the anterior and posterior obturator vessels were, respectively, 2.3 ± 0.5 cm and 3.2 ± 0.7 cm. During transgluteal posterior repair the distance between the cannula guide and the ischial spine was 1.7 ± 0.5 cm while it measured 2.3 ± 0.4 cm when single incision posterior device was placed. Anterior transobturator system presents an increased risk of posterior obturator vessels branches injury. During posterior transgluteal repair the distance of the ischio-anal fossa to sacrospinous ligament represents a way that could rule against the correct needle positioning with increased risk of pudendal lesions. Single incision approach offers an easier access to the sacrospinous ligament with lower risk of pudendal lesions. © 2017 Wiley Periodicals, Inc.

  19. Distal biceps brachii tendon repairs: a single-incision technique using a cortical button with interference screw versus a double-incision technique using suture fixation through bone tunnels.

    Science.gov (United States)

    Shields, Edward; Olsen, Joshua R; Williams, Richard B; Rouse, Lucien; Maloney, Michael; Voloshin, Ilya

    2015-05-01

    Distal biceps brachii tendon repairs performed with a tension slide technique using a cortical button (CB) and interference screw are stronger than those based on suture fixation through bone tunnels (BTs) in biomechanical studies. However, clinical comparison of these 2 techniques is lacking in the literature. To perform a clinical comparison of the single-incision CB and double-incision BT techniques. Cohort study; Level of evidence, 3. Distal biceps tendon ruptures repaired through either the single-incision CB or double-incision BT technique were retrospectively identified at a single institution. Patients>1 year out from surgery were assessed for range of motion, strength, and complications, and they completed a DASH questionnaire (Disabilities of the Arm, Shoulder, and Hand). Patients in the CB group (n=20) were older (52±9.5 vs 43.7±8.7 years; P=.008), had a shorter interval from surgery to evaluation (17.7±5 vs 30.8±16.5 months; P=.001), and were less likely to smoke (0% vs 28.5%; P=.02) compared with the BT patients (n=21). DASH scores were similar between groups (4.46±4.4 [CB] vs 5.7±7.5 [BT]; P=.65). Multivariate analysis revealed no differences in range of motion or strength between groups. More CB patients (30%; n=6) experienced a complication compared with those in the BT group (4.8%; n=1) (P=.04), and these complications were predominantly paresthesias of the superficial radial nerve that did not resolve. There were no reoperations or repair failures in either group. Both the single-incision CB and double-incision BT techniques provided excellent clinical results. Complications were more common in the single-incision CB group and most commonly involved paresthesias of the superficial radial nerve. © 2015 The Author(s).

  20. A randomized controlled trial of uterine exteriorization versus in situ repair of the uterine incision during cesarean delivery.

    Science.gov (United States)

    El-Khayat, Waleed; Elsharkawi, Mohamed; Hassan, Amr

    2014-11-01

    To compare extra-abdominal repair of the uterine incision at cesarean delivery with in situ repair. The present study was a double-blind randomized controlled trial conducted at a university hospital in Egypt during 2012-2013, and included women with an indication for cesarean delivery. Extra-abdominal repair was used in group 1 (n=500) and in situ repair in group 2 (n=500). The primary outcome measure was the surgery duration. Surgery duration was significantly longer in group 1 than group 2 (49.9±2.3 minutes vs 39.9±1.8 minutes; P<0.001). More patients in group 1 than in group 2 had postoperative moderate-to-severe pain (165 [33.0%] vs 115 [23.0%]; P=0.001) and needed additional postoperative analgesia (100 [20.0%] vs 50 [10.0%]; P<0.001). Moreover, mean time to bowel movement was longer in group 1 than in group 2 (17.0±2.7 hours vs 14.0±1.9 hours; P<0.001). In situ uterine closure is more advantageous than extra-abdominal repair in terms of surgery duration, postoperative pain and need for additional analgesia, and return of bowel movement. ClinicalTrials.gov:NCT01723605. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  1. Tubularized incised plate urethroplasty with or without stent in Hypospadias repair: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Seyed Abdollah Mousavi

    2014-07-01

    Full Text Available Numerous methods for repair of hypospadias have been introduced. The technique of Tubularized Incised Plate urethroplasty has gained widespread acceptance. In the classical method of Tubularized Incised Plate urethroplasty, to divert urine flow and preventing urethral stenosis, a stent was used, but its necessity is questionable for some surgeons. In this paper we systematically compared the results of operations in different studies. Searching the databases such as PubMed, SCOPUS, and Google Scholar was done and articles found from January 1994 to September 2013 were included. Then articles about the impact of use or non-use of urinary catheters on surgical outcomes were analyzed. By reviewing 168 studies related to repair of hypospadias with TIP, we selected 11 studies that met our inclusion criteria which did not use a stent. A total of 708 children had urethroplasty using the TIP method without stent. The overall complication rate such as meatal stenosis and fistula compared with stents was not significant. It could tell us that at least in some cases especially in distal types, use of stent can be avoided, because its least benefit would be reduction of bladder spasm and urinary tract infections.

  2. [Repair of distal biceps brachii tendon ruptures: long term retrospective follow-up for two-incision technique].

    Science.gov (United States)

    Sigmundsson, Freyr Gauti; Olafsson, Ari H; Ingvarsson, Thorvaldur

    2009-01-01

    Rupture of the distal tendon of the biceps muscle is a rare injury. If unrepaired the patient will be left with weakness of supination of the arm and flexion in the elbow. Long term results for the 2-incision approach for tendon reinsertion are few but in this study we describe the long term, clinical, functional, and subjective results of surgical repair using the 2-incision method described by Boyd and Anderson. All patients who were operated at FSA hospital during the years 1986-2000 because of rupture of the distal tendon of the biceps muscle were asked to participate in the study. Twelve of 16 patients accepted and answered the DASH questionnaire. Strength was tested with handheld dynamometer and ROM where measured. Radiograph was taken of the affected arm. From 1986 through 2006 we operated on 16 patients because of rupture of the distal biceps tendon, one female and 15 male. Mean age at the time of rupture was 46 years (24-53).The average follow up were seven years (1-17). Ten of 12 patients were operated within two weeks from the injuries. No difference in strength was found between operated and non-operated arms. Late repair was associated with high DASH score and poor subjective results. Six patients developed heterotopic ossification but none of them developed radioulnar synostosis. One reoperation because entrapment of the median nerve was done. Despite heterotopic ossification and a small ROM deficit the Boyd and Anderson technique for repair of distal biceps ruptures yields good long term results in a low volume rural hospital. Early diagnosis and tendon reinsertion is of great importance to avoid persistent anterior elbow pain and poor subjective results.

  3. Patch bulging after plaque incision and grafting procedure for Peyronie’s disease. Surgical repair with a collagen fleece

    Directory of Open Access Journals (Sweden)

    Andrea Fabiani

    2015-07-01

    Full Text Available The incision/excision and grafting techniques (PIG for surgical therapy of Peyronie’s disease (PD have gained popularity in recent years. Several different graft materials have been used but the ideal graft has yet to be established. The use of grafting materials could cause complications. In the daily clinical practice it will always be more frequent to manage complications arising from their use. We present herein the case of a patch bulging repaired with a ready-to-use collagen fleece (Tachosil®, Takeda, Linz, Austria, Europe in a 61 years old man subjected to intervention of geometric corporoplasty with Paulo Egydio technique using an acellular collagen material (Xenform® patch, Boston Scientific, Natick, MA, USA as graft. We also discuss the possible implications of PIG procedure.

  4. Tubularized proximally-incised plate in distal/midshaft hypospadias repair

    Directory of Open Access Journals (Sweden)

    Antonio Marte

    2017-06-01

    Full Text Available The aim of this study was to verify the validity, feasibility, and the functional results, by uroflowmetry, of Tubularized proximallyincised plate technique in selected case of distal/midshaft hypospadias. Out of 120 patients scheduled to undergo TIP (or Snodgrass procedure, 23 were selected between January 2013 and January 2016 (19.1%. This case series comprised 16 patients with distal and 7 with midshaft hypospadias. Mean age at surgery was 2.9 years. The inclusion criteria were a deep and wide glandular groove and a proximal narrow urethral plate. The procedure was carried out as described by Snodgrass but the incision of the urethral plate, including the mucosal and submucosal tissue, was made only proximally, between the original meatus and the glandular groove in no case extending to the entire length of the plate. Postoperatively a foley catheter was left in place from 4 to 7 days. Uroflowmetry was performed when the patients age ranged from 2.5 to 5.7 years (mean age 3.11 years and mean follow-up 1.8 years, body surface 2. No patient presented fistulas nor perioperative complications. At uroflowmetry, eighteen patients presented values above the 25th percentile and 5 showed a borderline flow. All patients in this group remained stable without urinary symptoms. In selected cases, the tubularized proximally-incised plate yields satisfactory cosmetic and functional results for the treatment of midshaft proximal hypospadias. A long-term follow-up study is needed for further evaluation. Patient selection is crucial for the success of this technique.

  5. Closed incision prophylactic negative pressure wound therapy in patients undergoing major complex abdominal wall repair

    NARCIS (Netherlands)

    de Vries, F. E. E.; Atema, J. J.; Lapid, O.; Obdeijn, M. C.; Boermeester, M. A.

    2017-01-01

    Purpose To evaluate if incisional prophylactic negative pressure wound therapy (pNPWT) reduces wound infections and other wound complications in high-risk patients undergoing major complex ventral abdominal wall repair. Methods Retrospective before-after comparison nested in a consecutive series of

  6. The DNA Repair Repertoire of Mycobacterium smegmatis FenA Includes the Incision of DNA 5' Flaps and the Removal of 5' Adenylylated Products of Aborted Nick Ligation.

    Science.gov (United States)

    Uson, Maria Loressa; Ghosh, Shreya; Shuman, Stewart

    2017-09-01

    We characterize Mycobacterium smegmatis FenA as a manganese-dependent 5'-flap endonuclease homologous to the 5'-exonuclease of DNA polymerase I. FenA incises a nicked 5' flap between the first and second nucleotides of the duplex segment to yield a 1-nucleotide gapped DNA, which is then further resected in dinucleotide steps. Initial FenA cleavage at a Y-flap or nick occurs between the first and second nucleotides of the duplex. However, when the template 3' single strand is eliminated to create a 5'-tailed duplex, FenA incision shifts to between the second and third nucleotides. A double-flap substrate with a mobile junction (mimicking limited strand displacement synthesis during gap repair) is preferentially incised as the 1-nucleotide 3'-flap isomer, with the scissile phosphodiester shifted by one nucleotide versus a static double flap. FenA efficiently removes the 5' App(dN) terminus of an aborted nick ligation reaction intermediate, thereby highlighting FenA as an agent of repair of such lesions, which are formed under a variety of circumstances by bacterial NAD + -dependent DNA ligases and especially by mycobacterial DNA ligases D and C. IMPORTANCE Structure-specific DNA endonucleases are implicated in bacterial DNA replication, repair, and recombination, yet there is scant knowledge of the roster and catalytic repertoire of such nucleases in Mycobacteria This study identifies M. smegmatis FenA as a stand-alone endonuclease homologous to the 5'-exonuclease domain of mycobacterial DNA polymerase 1. FenA incises 5' flaps, 5' nicks, and 5' App(dN) intermediates of aborted nick ligation. The isolated N-terminal domain of M. smegmatis Pol1 is also shown to be a flap endonuclease. Copyright © 2017 American Society for Microbiology.

  7. Probing for DNA damage with β-hairpins: Similarities in incision efficiencies of bulky DNA adducts by prokaryotic and human nucleotide excision repair systems in vitro

    Science.gov (United States)

    Liu, Yang; Reeves, Dara; Kropachev, Konstantin; Cai, Yuqin; Ding, Shuang; Kolbanovskiy, Marina; Kolbanovskiy, Alexander; Bolton, Judith L.; Broyde, Suse; Van Houten, Bennett; Geacintov, Nicholas E.

    2011-01-01

    Nucleotide excision repair (NER) is an important prokaryotic and eukaryotic defense mechanism that removes a large variety of structurally distinct lesions in cellular DNA. While the proteins involved are completely different, the mode of action of these two repair systems is similar, involving a cut-and-patch mechanism in which an oligonucleotide sequence containing the lesion is excised. The prokaryotic and eukaryotic NER damage-recognition factors have common structural features of β-hairpin intrusion between the two DNA strands at the site of the lesion. In the present study, we explored the hypothesis that this common β-hairpin intrusion motif is mirrored in parallel NER incision efficiencies in the two systems. We have utilized human HeLa cell extracts and the prokaryotic UvrABC proteins to determine their relative NER incision efficiencies. We report here comparisons of relative NER efficiencies with a set of stereoisomeric DNA lesions derived from metabolites of benzo[a]pyrene and equine estrogens in different sequence contexts, utilizing 21 samples. We found a general qualitative trend towards similar relative NER incision efficiencies for ~ 65% of these substrates; the other cases deviate mostly by ~ 30% or less from a perfect correlation, although several more distant outliers are also evident. This resemblance is consistent with the hypothesis that lesion recognition through β-hairpin insertion, a common feature of the two systems, is facilitated by local thermodynamic destabilization induced by the lesions in both cases. In the case of the UvrABC system, varying the nature of the UvrC endonuclease, while maintaining the same UvrA/B proteins, can markedly affect the relative incision efficiencies. These observations suggest that, in addition to recognition involving the initial modified duplexes, downstream events involving UvrC can also play a role in distinguishing and processing different lesions in prokaryotic NER. PMID:21741328

  8. Feasibility of a tubularised incised-plate urethroplasty with double de-epithelised dartos flaps in a failed hypospadias repair: A preliminary report

    Directory of Open Access Journals (Sweden)

    Abdullah Yildiz

    2012-01-01

    Full Text Available Background: Reoperation for failed hypospadias has been considered to be seriously problematic. The dense fibrotic tissue causes difficulties in wound healing and increases the rate of complications. The tubularised incised-plate urethroplasty (TIPU method has become a preferred method for all varieties of hypospadias in the past decade. However, fistulas are still one of the most common complications of this technique. The aim of this paper was to present the preliminary results of TIPU procedure with double de-epithelised dartos flaps in failed hypospadias repair. Materials and Methods: All patients were treated between January 2009 and August 2010 by the same procedure, utilising TIPU with double de-epithelised dartos flaps. Vascularised ventral dartos flaps harvested from each side of the penis with their vascular supply were transposed to cover the suture line by wrapping them from either side of the penis. Results: There were 21 boys with failed hypospadias: 20 had previously undergone TIPU, and one Koyanagi repair. Patients presented with very large fistulas in four and dehiscence in 17. Repair of the failed hypospadias using TIPU with double de-epithelised dartos flaps was quite successful, with no fistula recurrence or dehiscence observed. Conclusion: The preliminary results showed that TIPU with double de-epithelised dartos flaps is a useful method of successfully repairing failed hypospadias.

  9. The feasibility and safety of single-incision totally extraperitoneal inguinal hernia repair after previous lower abdominal surgery: 350 procedures at a single center.

    Science.gov (United States)

    Wakasugi, Masaki; Suzuki, Yozo; Tei, Mitsuyoshi; Anno, Kana; Mikami, Tsubasa; Tsukada, Ryo; Koh, Masahiro; Furukawa, Kenta; Masuzawa, Toru; Kishi, Kentaro; Tanemura, Masahiro; Akamatsu, Hiroki

    2017-03-01

    To evaluate the feasibility and safety of single-incision laparoscopic surgery for totally extraperitoneal inguinal hernia repair (SILS-TEP) with previous lower abdominal surgery (PLAS). A retrospective analysis of 350 patients undergoing SILS-TEP for a primary inguinal hernia from January 2012 to December 2015 at Osaka Police Hospital was performed, and the outcomes of the patients with and without PLAS were compared. SILS-TEP was performed in 84 patients with PLAS and 266 patients without PLAS. Appendectomy was the most common previous operative procedure. There were more patients with an ASA score of ≥3 in the PLAS group than in the control group (p < 0.05). The mean operative time, and the rates of conversion and postoperative complications were comparable between the two groups. There were no cases of recurrence in either group. SILS-TEP could be safely performed in patients with PLAS and achieved better cosmetic outcomes than conventional laparoscopic surgery.

  10. Purse-string double-layer closure: a novel technique for repairing the uterine incision during cesarean section.

    Science.gov (United States)

    Turan, Cem; Büyükbayrak, Esra Esim; Yilmaz, Aylin Onan; Karsidag, Yasemin Karageyim; Pirimoglu, Meltem

    2015-04-01

    To compare the classical double-layer uterine closure to a double-layer purse-string uterine closure (Turan technique) in cesarean section regarding short- and long-term results. Patients were randomized into either the double-layer purse-string uterine closure arm (study group, 84 patients) or the classical double-layer uterine closure arm (control group, 84 patients). For short-term comparison, a detailed transvaginal ultrasound examination was planned in all patients 6 weeks after the operation and a wedge-shaped defect in the uterine incision scar was accepted as uterine scar defect and recorded. For the long-term comparison, subsequent pregnancies of these patients were followed up for any complication. The number of patients with ultrasonographically visible uterine scar defect was 12 (23.5% of all scar defects) in the study group whereas it was 39 (76.5% of all scar defects) in the control group (P complication during their pregnancies and second cesarean operation were encountered. With the Turan technique, the uterine incision length becomes shorter, and the frequency of uterine scar defect is lower regarding short-term results. More data is needed for long-term results. ClinicalTrials.gov NCT01287611. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  11. Structural comparison of AP endonucleases from the exonuclease III family reveals new amino acid residues in human AP endonuclease 1 that are involved in incision of damaged DNA.

    Science.gov (United States)

    Redrejo-Rodríguez, Modesto; Vigouroux, Armelle; Mursalimov, Aibek; Grin, Inga; Alili, Doria; Koshenov, Zhanat; Akishev, Zhiger; Maksimenko, Andrei; Bissenbaev, Amangeldy K; Matkarimov, Bakhyt T; Saparbaev, Murat; Ishchenko, Alexander A; Moréra, Solange

    2016-01-01

    Oxidatively damaged DNA bases are substrates for two overlapping repair pathways: DNA glycosylase-initiated base excision repair (BER) and apurinic/apyrimidinic (AP) endonuclease-initiated nucleotide incision repair (NIR). In the BER pathway, an AP endonuclease cleaves DNA at AP sites and 3'-blocking moieties generated by DNA glycosylases, whereas in the NIR pathway, the same AP endonuclease incises DNA 5' to an oxidized base. The majority of characterized AP endonucleases possess classic BER activities, and approximately a half of them can also have a NIR activity. At present, the molecular mechanism underlying DNA substrate specificity of AP endonucleases remains unclear mainly due to the absence of a published structure of the enzyme in complex with a damaged base. To identify critical residues involved in the NIR function, we performed biochemical and structural characterization of Bacillus subtilis AP endonuclease ExoA and compared its crystal structure with the structures of other AP endonucleases: Escherichia coli exonuclease III (Xth), human APE1, and archaeal Mth212. We found conserved amino acid residues in the NIR-specific enzymes APE1, Mth212, and ExoA. Four of these positions were studied by means of point mutations in APE1: we applied substitution with the corresponding residue found in NIR-deficient E. coli Xth (Y128H, N174Q, G231S, and T268D). The APE1-T268D mutant showed a drastically decreased NIR activity and an inverted Mg(2+) dependence of the AP site cleavage activity, which is in line with the presence of an aspartic residue at the equivalent position among other known NIR-deficient AP endonucleases. Taken together, these data show that NIR is an evolutionarily conserved function in the Xth family of AP endonucleases. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Conserved structural chemistry for incision activity in structurally non-homologous apurinic/apyrimidinic endonuclease APE1 and endonuclease IV DNA repair enzymes.

    Energy Technology Data Exchange (ETDEWEB)

    Tsutakawa, Susan E.; Shin, David S.; Mol, Clifford D.; Izum, Tadahide; Arvai, Andrew S.; Mantha, Anil K.; Szczesny, Bartosz; Ivanov, Ivaylo N.; Hosfield, David J.; Maiti, Buddhadev; Pique, Mike E.; Frankel, Kenneth A.; Hitomi, Kenichi; Cunningham, Richard P.; Mitra, Sankar; Tainer, John A.

    2013-03-22

    Non-coding apurinic/apyrimidinic (AP) sites in DNA form spontaneously and as DNA base excision repair intermediates are the most common toxic and mutagenic in vivo DNA lesion. For repair, AP sites must be processed by 5' AP endonucleases in initial stages of base repair. Human APE1 and bacterial Nfo represent the two conserved 5' AP endonuclease families in the biosphere; they both recognize AP sites and incise the phosphodiester backbone 5' to the lesion, yet they lack similar structures and metal ion requirements. Here, we determined and analyzed crystal structures of a 2.4 ? resolution APE1-DNA product complex with Mg(2+) and a 0.92 Nfo with three metal ions. Structural and biochemical comparisons of these two evolutionarily distinct enzymes characterize key APE1 catalytic residues that are potentially functionally similar to Nfo active site components, as further tested and supported by computational analyses. We observe a magnesium-water cluster in the APE1 active site, with only Glu-96 forming the direct protein coordination to the Mg(2+). Despite differences in structure and metal requirements of APE1 and Nfo, comparison of their active site structures surprisingly reveals strong geometric conservation of the catalytic reaction, with APE1 catalytic side chains positioned analogously to Nfo metal positions, suggesting surprising functional equivalence between Nfo metal ions and APE1 residues. The finding that APE1 residues are positioned to substitute for Nfo metal ions is supported by the impact of mutations on activity. Collectively, the results illuminate the activities of residues, metal ions, and active site features for abasic site endonucleases.

  13. What is the best choice for repair of distal penile hypospadias: The tubularized incised plate urethroplasty or anterior urethral advancement technique?

    Directory of Open Access Journals (Sweden)

    Awad Mohamed

    2007-01-01

    Full Text Available Background and Aim: Numerous ingenious methods have been introduced to repair hypospadias with variable results. We tried to evaluate the two techniques, tubularized incised plate urethroplasty (TIP and anterior urethral advancement (AUA for repair of distal hypospadias and choose the best method to treat the distal type of penile hypospadias with the least complications. Materials and Methods : A total of 140 boys with distal penile hypospadias were divided into two groups. Group A (68 patients was treated with TIP and Group B (72 patients was treated with AUA. All the patients had an average age of three years (2-19 with variable meatal sites coronal (44 sub coronal (53 and anterior penile hypospadias (43. There was no significant difference between both groups with respect to the age and meatal sites. Results: The fistula rate in Group A was 8.8% versus 1.3% in Group B. There was no urethral stricture in both procedures. Wound dehiscence did not occur in Group A versus one case in Group B (1.3%. In Group A, 26 cases (38.3% had mild glanular torsion and five (7.3% had moderate glanular torsion versus none in Group B postoperatively. No postoperative chordee or binding in Group A, versus four patients (5.5% in Group B. No significant difference was observed in both groups with respect to meatal stenosis (7.3% versus 5.5% respectively. There was a significant difference between both groups with regard to the operative time in favour of Group B. Good cosmetic appearance of the glans was achieved in both techniques. Conclusion: Both techniques can treat this anomaly with a high success rate but the modified AUA technique appears to be a good choice due to its simplicity, short operative time and less fistula rate with good cosmetic results.

  14. Tubularized Incised Plate (TIP) Urethroplasty: Extended Use in ...

    African Journals Online (AJOL)

    Objective: Recently, tubularized incised plate (TIP) urethroplasty (Snodgrass repair) has gained popularity for the primary repair of distal and proximal hypospadias. This study was carried out to evaluate TIP urethroplasty in the repair of failed and complicated hypospadias cases. Patients and Methods: This study was ...

  15. Incised plate urethroplasty in perineal and perineo-scrotal ...

    African Journals Online (AJOL)

    Objective: The ideal replacement of the urethra is the urethra itself. However, when the urethra is not available, flaps or tubes are used as substitutes in hypospadias repair. The urethral plate, when preserved, is an excellent tool for tubularization and urethral reconstruction. Tubularized incise plate (TIP) repair has become ...

  16. Incised plate urethroplasty in perineal and perineo-scrotal ...

    African Journals Online (AJOL)

    A. Bhat

    Abstract. Objective: The ideal replacement of the urethra is the urethra itself. However, when the urethra is not available, flaps or tubes are used as substitutes in hypospadias repair. The urethral plate, when preserved, is an excellent tool for tubularization and urethral reconstruction. Tubularized incise plate (TIP) repair.

  17. Alopecia Following Bicoronal Incisions.

    Science.gov (United States)

    Kadakia, Sameep; Badhey, Arvind; Ashai, Sara; Lee, Thomas S; Ducic, Yadranko

    2017-05-01

    Multiple techniques may be used to perform bicoronal incisions, and alopecia is a known postoperative complication of this procedure. To date, no large studies exist comparing alopecia outcomes among bicoronal incision techniques with and without the use of Raney clips. To determine (1) whether postoperative alopecia is more common when bicoronal incisions are performed with monopolar cautery, Colorado microdissection tip cautery, or traditional cold steel and (2) whether this outcome is affected by the use of Raney clips. This retrospective study of postoperative alopecia included 505 patients undergoing bicoronal incisions in a single head and neck surgery practice from 1997 to 2015 with a minimum follow-up of 1 year. Patients with preexisting baldness as well as patients not following up for the minimum period were excluded. All data analysis took place between 1997 and 2015. Maximum alopecia width was measured in the postoperative period and compared among the technique groups both with and without Raney clip use. Raney clip duration as a product of surgery length was also compared. A total of 505 patients (301 male, 204 female) ranging in age from 3 to 97 years were included in the study (median age, 53.9 years). Of these, 236 underwent bicoronal incisions to approach the skull base, 78 to treat chronic frontal sinusitis unresponsive to endoscopic management or frontal sinus mucocele, 143 for trauma, and 48 for craniofacial surgery. For 173 patients, the cold steel technique was used for both skin and subcutaneous incision, 102 of whom needed Raney clips. For 161 patients, cold steel technique was used for skin incisions and monopolar cautery for subcutaneous incision; 81 of these patients required Raney clips. For 171 patients, Colorado tip microdissection cautery was used for both skin and subcutaneous incision, with Raney clips used in 66 of these patients. Incisions made with cold steel for both skin and subcutaneous tissue, regardless of Raney clip use

  18. UV-induced DNA incision and proliferating cell nuclear antigen recruitment to repair sites occur independently of p53-replication protein A interaction in p53 wild type and mutant ovarian carcinoma cells

    NARCIS (Netherlands)

    Riva, F.; Zuco, V.; Vink, A.A.; Supino, R.; Prosperi, E.

    2001-01-01

    The tumour suppressor gene TP53 plays an important role in the regulation of DNA repair, and particularly of nucleotide excision repair. The influence of p53 status on the efficiency of the principal steps of this repair pathway was investigated after UV-C irradiation in the human ovarian carcinoma

  19. NIR Analysis for Textiles

    Science.gov (United States)

    Near Infrared (NIR) spectroscopy has been found to be a useful technique to characterize raw materials and finished textile products, and NIR methods and techniques continue to find increasingly diverse and wide-ranging quantitative and qualitative applications in the textile industry. NIR methods ...

  20. The mandibular incisive foramen.

    OpenAIRE

    Serman, N J

    1989-01-01

    An anatomical variant in the region of the mental foramen is discussed. In these cases the inferior alveolar nerve divides into its two terminal branches only after it has exited through the mental foramen. The incisive nerve thus commences outside the mandible, and has a short extra-osseous course before it enters the mandible through a separate foramen on the same horizontal plane. For the distance between these two foramina there is no nerve supply within the mandible. The groove between t...

  1. Long-Term Incisal Relationships After Palatoplasty in Patients With Isolated Cleft Palate.

    Science.gov (United States)

    Odom, Elizabeth B; Woo, Albert S; Mendonca, Derick A; Huebener, Donald V; Nissen, Richard J; Skolnick, Gary B; Patel, Kamlesh B

    2016-06-01

    Various palatoplasty techniques have limited incisions in the hard palate due to concerns that these incisions may limit maxillary growth. There is little convincing long-term evidence to support this. Our purpose is to determine incisal relationships, an indicator for future orthognathic procedure, in patients after repair of an isolated cleft of the secondary palate. Our craniofacial database was used to identify patients aged 10 years or greater with an isolated cleft of the secondary palate who underwent palatoplasty between 1985 and 2002. Data collected included age at palatoplasty and follow-up, cleft type, associated syndrome, Robin sequence, surgeon, repair technique, number of operations, and occlusion. Incisal relationship was determined through clinical observation by a pediatric dentist and orthodontist. Seventy eligible patients operated on by 9 surgeons were identified. Class III incisal relationship was seen in 5 patients (7.1%). Palatoplasty techniques over the hard palate (63 of 70 patients) included 2-flap palatoplasty, VY-pushback, and Von Langenbeck repair. There was an association between class III incisal relationship and syndromic diagnosis (P cleft of the secondary palate, there was no association between class III incisal relationship and surgeon, age at repair, cleft type, palatoplasty technique, or number of operations. Increased likelihood of class III incisal relationship was associated primarily with syndromic diagnosis.

  2. The inverted Batman incision: a new incision in transcolumellar incision for open rhinoplasty.

    Science.gov (United States)

    Nakanishi, Yuji; Nagasao, Tomohisa; Shimizu, Yusuke; Miyamoto, Junpei; Fukuta, Keizo; Kishi, Kazuo

    2013-12-01

    Columellar and nostril shapes often present irregularity after transcolumellar incision for open rhinoplasty, because of the contracture of the incised wound. The present study introduces a new technique to prevent this complication, and verifies its efficacy in improving cosmetic appearance. In our new method, a zig-zag incision with three small triangular flaps is made on the columella and in the pericolumellar regions of the bilateral nostril rims. Since the shape of the incision resembles the contour of an inverted "batman", we term our new method the "Inverted Batman" incision. To verify the effectiveness of the Inverted Batman incision, aesthetic evaluation was conducted for 21 patients operated on using the conventional transcolumellar incision (Conventional Group) and 19 patients operated on using the Inverted Batman incision (Inverted Batman Group). The evaluation was performed by three plastic surgeons, using a four-grade scale to assess three separate items: symmetry of bilateral soft triangles, symmetry of bilateral margins of the columella, and evenness of the columellar surface. The scores of the two groups for these three items were compared using a non-parametric test (Mann-Whitney U-test). With all three items, the Inverted Batman group patients present higher scores than Conventional Group patients. The Inverted Batman incision is effective in preserving the correct anatomical structure of the columella, soft triangle, and nostril rims. Hence, we recommend the Inverted Batman incision as a useful technique for open rhinoplasty.

  3. The fourth incision: a cosmetic autopsy incision technique.

    Science.gov (United States)

    Patowary, Amarjyoti

    2010-03-01

    Autopsy procedure includes thorough external examination as well as internal examination including opening of all the body cavities for proper visualization of all the visceral organs. As such, there remains incision marks with stitches which harts the sentiment of the already traumatized relatives of the deceased. Moreover, it looks odd especially in cases of otherwise healthy dead bodies. So, autopsy incisions should be such that, we can get maximum possible visualization of the body cavities, particularly the thorax and abdomen, and at the same time the incision as well as the stitch marks are also hidden. This article is aimed to describe few modifications in the autopsy incisions for opening the thorax and abdomen and also proper visualization of the neck structures during autopsy where the incisions and the stitches are kept hidden.

  4. Effects of post-treatment incubation on recombinogenesis in incision-proficient and incision-deficient strains of saccharomyces cerevisiae, 2

    International Nuclear Information System (INIS)

    Saeki, Tetsuya; Machida, Isamu

    1991-01-01

    After the photoaddition of mono- and bifunctional furocoumarins to G1 phase cells, most gene conversion and crossing-over occurred without post-irradiation incubation of these cells in incision-proficient strains. In contrast, incision-deficient cells showed marked induction of both recombinational events only after treated cells had been incubated for several hours before selection. These results indicate that when furocoumarins are photoadded to G1 cells, initiation of recombinational events occurs during the same G1 phase in the incision-proficient cells; whereas, it occurs only after post-irradiation DNA replication in incision-deficient cells. The action of the PSO2 gene product specific for the repair of DNA crosslinks in recombination induction is discussed and compared to the actions of the excision repair genes RAD1 and RAD2. (author)

  5. Dorsal inlay inner preputial graft for primary hypospadias repair ...

    African Journals Online (AJOL)

    Background: The most commonly performed operation to repair distal hypospadias is the Tubularised incised plate (TIP) repair. The key step is midline incision of the urethral plate, which widens a narrow plate and converts a flat into a deep plate groove, ensuring a vertical, slit neomeatus and a normal-calibre neourethra.

  6. Diversity of nitrite reductase (nirK and nirS) gene fragments in forested upland and wetland soils

    DEFF Research Database (Denmark)

    Priemé, Anders; Braker, Gesche; Tiedje, James M.

    2002-01-01

    The genetic heterogeneity of nitrite reductase gene (nirK and nirS) fragments from denitrifying prokaryotes in forested upland and marsh soil was investigated using molecular methods. nirK gene fragments could be amplified from both soils, whereas nirS gene fragments could be amplified only from...... the marsh soil. PCR products were cloned and screened by restriction fragment length polymorphism (RFLP), and representative fragments were sequenced. The diversity of nirK clones was lower than the diversity of nirS clones. Among the 54 distinct nirK RFLP patterns identified in the two soils, only one...... marsh clones and all upland clones. Only a few of the nirK clone sequences branched with those of known denitrifying bacteria. The nirS clones formed two major clusters with several subclusters, but all nirS clones showed less than 80% identity to nirS sequences from known denitrifying bacteria. Overall...

  7. Maturation of the cytochrome cd1 nitrite reductase NirS from Pseudomonas aeruginosa requires transient interactions between the three proteins NirS, NirN and NirF.

    OpenAIRE

    Nicke, Tristan; Schnitzer, Tobias; Münch, Karin; Adamczack, Julia; Haufschildt, Kristin; Buchmeier, Sabine; Kucklick, Martin; Felgenträger, Undine; Jänsch, Lothar; Riedel, Katharina; Layer, Gunhild

    2013-01-01

    The periplasmic cytochrome cd 1 nitrite reductase NirS occurring in denitrifying bacteria such as the human pathogen Pseudomonas aeruginosa contains the essential tetrapyrrole cofactors haem c and haem d 1. Whereas the haem?c is incorporated into NirS by the cytochrome c maturation system I, nothing is known about the insertion of the haem d 1 into NirS. Here, we show by co-immunoprecipitation that NirS interacts with the potential haem d 1 insertion protein NirN in?vivo. This NirS?NirN inter...

  8. NIRS in Space?

    Science.gov (United States)

    Peterson, David L.; Condon, Estelle (Technical Monitor)

    2000-01-01

    Proponents of near infrared reflectance spectroscopy (NIRS) have been exceptionally successful in applying NIRS techniques to many instances of organic material analyses. While this research and development began in the 1950s, in recent years, stimulation of advancements in instrumentation is allowing NIRS to begin to find its way into the food processing systems, into food quality and safety, textiles and much more. And, imaging high spectral resolution spectrometers are now being evaluated for the rapid scanning of foodstuffs, such as the inspection of whole chicken carcasses for fecal contamination. The imaging methods are also finding their way into medical applications, such as the non-intrusive monitoring of blood oxygenation in newborns. Can these scientific insights also be taken into space and successfully used to measure the Earth's condition? Is there an analog between the organic analyses in the laboratory and clinical settings and the study of Earth's living biosphere? How are the methods comparable and how do they differ?

  9. Single incision pediatric endoscopic surgery: advantages of relatively large incision

    International Nuclear Information System (INIS)

    Yilmaz, E.; Afsarlar, E.; Karaman, I.

    2015-01-01

    To describe Single Incision Pediatric Endoscopic Surgery (SIPES) performed on children with various diagnoses, emphasizing its advantages. Study Design: An observational case series. Place and Duration of Study: Department of Pediatric Surgery, Dr. Sami Ulus Maternity and Child Health Hospital, Ankara, Turkey, from January 2011 to November 2014. Methodology: A review of patient charts was conducted in which SIPES was preferred as the surgical procedure. Patient demographics, operative details, operative time, clinical outcomes, postoperative pain and cosmesis were analyzed. Results: SIPES was performed on 45 patients (21 girls, 24 boys). Thirty-three appendectomies, 5 varicocelectomies, 3 oophorectomies, 2 ovarian and one paratubal cyst excision, and one fallopian tube excision were performed. All except one procedures were performed through our standard 2cm umbilical vertical or smile incision. In 18 cases, abdominal irrigation/aspiration was easily performed through the existing larger incision, as is done with open surgical technique. None of the patients had early postoperative shoulder/back pain since complete disinflation of CO/sub 2/ could be ensured. All of the patients/parents were satisfied with the cosmesis. Conclusion: SIPES has the advantages of limiting the surgical scar to within the umbilicus and providing easy disinflation of CO/sub 2/, allowing intraabdominal cleaning and extraction of large volume tissue samples through a single large umbilical incision. (author)

  10. Incision for pleural tissue biopsy (image)

    Science.gov (United States)

    ... open pleural biopsy, a small piece of the pleural tissue is removed through a surgical incision in the chest. After the sample is obtained, a chest tube is placed and the incision is closed with ...

  11. In vivo near infrared (NIRS) sensor attachment using fibrin bioadhesive

    Science.gov (United States)

    Macnab, Andrew; Pagano, Roberto; Kwon, Brian; Dumont, Guy; Shadgan, Babak

    2018-02-01

    Background: `Tisseel' (Baxter Healthcare, Deerfield, IL) is a fibrin-based sealant that is commonly used during spine surgery to augment dural repairs. We wish to intra-operatively secure a near infrared spectroscopy (NIRS) sensor to the dura in order to monitor the tissue hemodynamics of the underlying spinal cord. To determine if `Tisseel' sealant adversely attenuates NIR photon transmission. Methods: We investigated `Tisseel' in both an in vitro and in vivo paradigm. For in vitro testing, we used a 1 mm pathlength cuvette containing either air or `Tisseel' interposed between a NIR light source (760 and 850 nm) and a photodiode detector and compared transmittance. For in vivo testing, a continuous wave (760 and 850 nm) spatiallyresolved NIRS device was placed over the triceps muscle using either conventional skin apposition (overlying adhesive bandage) or bioadhesion with `Tisseel'. Raw optical data and tissue saturation index (TSI%) collected at rest were compared. Results: In-vitro NIR light absorption by `Tisseel' was very high, with transmittance reduced by 95% compared to air. In-vivo muscle TSI% values were 80% with conventional attachment and 20% using fibrin glue. Conclusion: The optical properties of `Tisseel' significantly attenuate NIR light during in-vitro transmittance and critically compromise photon transmission in-vivo.

  12. On children's dyslexia with NIRS

    Science.gov (United States)

    Gan, Zhuo; Li, Chengjun; Gong, Hui; Luo, Qingming; Yao, Bin; Song, Ranran; Wu, Hanrong

    2003-12-01

    Developmental dyslexia is a kind of prevalent psychologic disease. Some functional imaging technologies, such as FMRI and PET, have been used to study the brain activities of dyslexics. NIRS is a kind of novel technology which is more and more widely being used for study of the cognitive psychology. However, there aren"t reports about the dyslexic research using NIRS to be found until now. This paper introduces a NIRS system of four measuring channels. Brain activities of dyslexic subjects and normal subjects during reading task were studied with the NIRS system. Two groups of subjects, the group of dyslexia and the group of normal, were appointed to perform two reading tasks. At the same time, their cortical activities were measured with the NIRS system. This experimental result indicates that the brain activities of the dyslexic group were significantly higher than the control group in BA 48 and that NIRS can be used for the study of human brain activity.

  13. Three versus four radial keratotomy incisions.

    Science.gov (United States)

    Melles, G R; Go, A T; Beekhuis, W H; van Rij, G; Binder, P S

    1992-01-01

    Radial keratotomy (RK) is currently performed with four or eight semi-radial incisions. To evaluate the effect of a theoretically more stable three-incision RK pattern, centripetal incisions were made in 16 human donor eyes (eight pairs), using a double-edged diamond blade set to 90% of central pachymetry and a 3.5 mm optical clear zone. Intraocular pressure was maintained at 15 mm Hg during surgery and while keratometry readings were made. One randomly selected eye of each pair had three radial incisions made at 12, 4 and 8 o'clock; the other eye had four radial incisions at 12, 3, 6, and 9 o'clock. Corneal flattening was 6.08 diopters (D) with four incisions and 4.84 D with three incisions (P less than .05). Astigmatism increased 0.44 D and 0.69 D, respectively (P greater than .1). Histologically measured mean incision depth (77.4%) did not differ significantly between the groups (P greater than .1). This study shows that 80% of the effect of a four-incision RK pattern can be obtained with a theoretically more stable three-incision pattern.

  14. Modified tubularized incised plate urethroplasty

    Directory of Open Access Journals (Sweden)

    Shivaji Mane

    2013-01-01

    Full Text Available Aim: To share our experience of doing tubularized incised plate urethroplasty with modifications. Materials and Methods: This is a single surgeon personal series from 2004 to 2009. One hundred patients of distal hypospadias were subjected for Snodgrass urethroplasty with preputioplasty. The age range was 1 to 5 year with mean age of 2.7 years. Selection criteria were good urethral plate, without chordee and torsion needing complete degloving. Main technical modification from original Snodgrass procedure was spongioplasty, preputioplasty, and dorsal slit when inability to retract prepuce during surgery. Results: Average follow-up period is 23 months. Seven (7% patients developed fistula and one patient had complete preputial dehiscence. Phimosis developed in three (3% patients and required circumcision. Dorsal slit was required in seven patients. One patient developed meatal stenosis in postoperative period. All other patients are passing single urinary stream and have cosmesis that is acceptable. Conclusions: Modified tubularized incised plate urethroplasty with preputioplasty effectively gives cosmetically normal looking penis with low complications.

  15. Mesenchymal stem cells promote incision wound repair in a mouse ...

    African Journals Online (AJOL)

    Care Committee of the Department of Burn and. Plastic Surgery, Affiliated Hospital of PLA. General Hospital (approval no. 4203441). All experimental procedures were conducted in accordance with institutional guidelines and conformed to the National Research Council. Guide for Care and Use of Laboratory Animals. [15].

  16. Mesenchymal stem cells promote incision wound repair in a mouse ...

    African Journals Online (AJOL)

    Chalkley method was used to determine vascular density. A score was given, for each field examined, for CD31-positive areas, and the results of blind analysis were confirmed by independent analysis of a second evaluator. Results: The tensile strength of the wound area was significantly lower in older versus younger mice ...

  17. Tubularized incised plate urethroplasty repair in adult hypospadias ...

    African Journals Online (AJOL)

    A. Bhat

    2016-03-05

    Mar 5, 2016 ... Received 5 November 2014; received in revised form 23 March 2015; accepted 1st April 2015. Available online 5 March ... patients with a narrow urethral plate developed complications, compared to 15% of the patients whose ... In such cases, single-stage flap urethroplasty or two-stage buccal mucosal.

  18. NIR annual report 1987

    International Nuclear Information System (INIS)

    1988-01-01

    The fourth annual report of the Niedersaechsisches Institut fuer Radiooekologie (NIR) is intended to describe the scientific work of the institute and its members in 1987. The central part of this publication are the fourteen reports on scientific activities, to be divided into four large categories: - Behaviour of tritium in the atmosphere and the soil - on this, important new knowledge was gained in 1987 in an experiment in Canada on the release of this substance; - Investigations in the radioecology of iodine 129, the dependence of its mobility in the soil on humus substances and microorganisms, and its enrichment in the human thyroid gland; - Establishment of transfer factors in the food chain for fission products like cesium 137, cesium 134 and strontium 90 - this being a field where exact knowledge has regained great importance after the accident at Chernobyl; - Aerosol-physical investigations: on the one hand, to obtain data on the propagation of nutrient aerosols and aerosols carrying harmful substances in areas with vegetation, and on the other hand to measure 'snow-out' and 'fog-out' coefficients. To this are added a number of papers on the stability of the decontamination substance for cesium 137 - ammonium-iron-hexacyanoferrate (AIHCF) - in the soil, on the translocation of cesium in apple-trees, and on the improvement of the analytics for uranium and plutonium in environmental specimens. (orig./MG) [de

  19. Single-incision total laparoscopic hysterectomy

    Directory of Open Access Journals (Sweden)

    Sinha Rakesh

    2011-01-01

    Full Text Available Single-incision laparoscopic surgery is an alternative to conventional multiport laparoscopy. Single-access laparoscopy using a transumbilical port affords maximum cosmetic benefits because the surgical incision is hidden in the umbilicus. The advantages of single-access laparoscopic surgery may include less bleeding, infection, and hernia formation and better cosmetic outcome and less pain. The disadvantages and limitations include longer surgery time, difficulty in learning the technique, and the need for specialized instruments. Ongoing refinement of the surgical technique and instrumentation is likely to expand its role in gynecologic surgery in the future. We perform single-incision total laparoscopic hysterectomy using three ports in the single transumbilical incision.

  20. Single Incision Laparoscopic Splenectomy: Our First Experiences

    Directory of Open Access Journals (Sweden)

    Umut Barbaros

    2011-06-01

    Full Text Available Objective: Most laparoscopic surgeons have attempted to reduce incisional morbidity and improve cosmetic outcomes by using less and smaller trocars. Single incision laparoscopic splenectomy is a new laparoscopic procedure. Herein we would like to present our experiences.Material and Methods: Between January 2009 and June 2009, data of the 7 patients who underwent single incision laparoscopic splenectomy were evaluated retrospectively.Results: There were 7 patients (5 females and 2 males with a mean age of 29.9 years. The most common splenectomy indication was idiopathic thrombocytopenic purpura. Single incision laparoscopic splenectomy was performed successfully in 6 patients. In one patient the operation was converted to an open procedure.Conclusion: With surgeons experienced in minimally invasive surgery, single incision laparoscopic splenectomy could be performed successfully. However, in order to demonstrate the differneces between standard laparoscopic splenectomy and SILS splenetomy, prospective randomized comparative studies are required.

  1. Mast Quadrant-assisted Minimally Invasive Modified Transforaminal Lumbar Interbody Fusion: Single Incision Versus Double Incision

    Directory of Open Access Journals (Sweden)

    Xin-Lei Xia

    2015-01-01

    Full Text Available Background: The concept of minimally invasive techniques is to make every effort to reduce tissue damage. Certainly, reducing skin incision is an important part of these techniques. This study aimed to investigate the clinical feasibility of Mast Quadrant-assisted modified transforaminal lumbar interbody fusion (TLIF with a small single posterior median incision. Methods: During the period of March 2011 to March 2012, 34 patients with single-segment degenerative lumbar disease underwent the minimally invasive modified TLIF assisted by Mast Quadrant with a small single posterior median incision (single incision group. The cases in this group were compared to 37 patients with single-segment degenerative lumbar disease in the double incision group. The perioperative conditions of patients in these two groups were statistically analyzed and compared. The Oswestry Disability Index (ODI scores, Visual Analog Scale (VAS scores, and sacrospinalis muscle damage evaluation indicators before operation and 3, 12 months postoperation were compared. Results: A total of 31 and 35 cases in the single incision and double incision groups, respectively, completed at least 12 months of systemic follow-up. The differences in perioperative conditions between the two groups were not statistically significant. The incision length of the single incision group was significantly shorter than that of the double incision group (P < 0.01. The ODI and VAS scores of patients in both groups improved significantly at 3 and 12 months postoperation. However, these two indicators at 3 and 12 months postoperation and the sacrospinalis muscle damage evaluation indicators at 3 months postoperation did not differ significantly between the two groups (P ≥ 0.05. Conclusions: Mast Quadrant-assisted modified TLIF with a small single posterior median incision has excellent clinical feasibility compared to minimally invasive TLIF with a double paramedian incision.

  2. Surgical Treatment of Distal Biceps Tendon Ruptures: An Analysis of Complications in 784 Surgical Repairs.

    Science.gov (United States)

    Dunphy, Taylor R; Hudson, Justin; Batech, Michael; Acevedo, Daniel C; Mirzayan, Raffy

    2017-11-01

    Distal biceps brachii tendon ruptures lead to substantial deficits in elbow flexion and supination; surgical repair restores muscle strength and endurance. To examine clinical and surgical outcomes for distal biceps tendon repairs in a large, multispecialty, integrated health care system. Cohort study; Level of evidence, 3. Retrospective cohort study of distal biceps tendon repairs performed between January 1, 2008, and December 31, 2015. The repair methods were classified as double-incision approach using bone tunnel-suture fixation or anterior single-incision approach. Anterior single incisions were further classified according to the fixation method: cortical button alone, cortical button and interference screw, or suture anchors alone. Patient demographics, surgeon characteristics, range of motion, and complications were analyzed for all repair types. Of the 784 repairs that met the inclusion criteria, 639 (81.5%) were single-incision approaches. When comparing double-incision and single-incision repairs, there was a significantly higher rate of posterior interosseous nerve palsy (3.4% vs 0.8%, P = .010), heterotopic bone formation (7.6% vs 2.7%, P = .004), and reoperation (8.3% vs 2.3%, P biceps tendon ruptures has an overall low rate of serious complications, regardless of approach or technique. However, the double-incision technique has a higher rate of posterior interosseous nerve palsy, heterotopic bone formation, and reoperation rate. Surgeon's years of practice, fellowship training, and case volume do not affect the rate of major complications.

  3. DNA Methylation Modulates Nociceptive Sensitization after Incision.

    Directory of Open Access Journals (Sweden)

    Yuan Sun

    Full Text Available DNA methylation is a key epigenetic mechanism controlling DNA accessibility and gene expression. Blockade of DNA methylation can significantly affect pain behaviors implicated in neuropathic and inflammatory pain. However, the role of DNA methylation with regard to postoperative pain has not yet been explored. In this study we sought to investigate the role of DNA methylation in modulating incisional pain and identify possible targets under DNA methylation and contributing to incisional pain. DNA methyltranferase (DNMT inhibitor 5-Aza-2'-deoxycytidine significantly reduced incision-induced mechanical allodynia and thermal sensitivity. Aza-2'-deoxycytidine also reduced hindpaw swelling after incision, suggesting an anti-inflammatory effect. Global DNA methylation and DNMT3b expression were increased in skin after incision, but none of DNMT1, DNMT3a or DNMT3b was altered in spinal cord or DRG. The expression of proopiomelanocortin Pomc encoding β-endorphin and Oprm1 encoding the mu-opioid receptor were upregulated peripherally after incision; moreover, Oprm1 expression was further increased under DNMT inhibitor treatment. Finally, local peripheral injection of the opioid receptor antagonist naloxone significantly exacerbated incision-induced mechanical hypersensitivity. These results suggest that DNA methylation is functionally relevant to incisional nociceptive sensitization, and that mu-opioid receptor signaling might be one methylation regulated pathway controlling sensitization after incision.

  4. Single scrotal incision orchiopexy - a systematic review

    Directory of Open Access Journals (Sweden)

    Hugo Fabiano Fernandes Novaes

    2013-06-01

    Full Text Available Objective To conduct a systematic review on single scrotal incision orchiopexy. Materials and Methods A search was performed using Pubmed, through which 16 articles were selected out of a total of 133. The following conditions were considered exclusion criteria: other surgical methods such as an inguinal procedure or a laparoscopic approach, retractile testes, or patients with previous testicular or inguinal surgery. Results A total of 1558 orchiopexy surgeries initiated with a transcrotal incision were analyzed. Patients' ages ranged between 5 months and 21 years. Thirteen studies used high scrotal incisions, and low scrotal incisions were performed in the remainder of the studies. In 55 cases (3.53%, there was a need for inguinal incision. Recurrence was observed in 9 cases, testicular atrophy in 3, testicular hypotrophy in 2, and surgical site infections in 13 cases. High efficacy rates were observed, varying between 88% and 100%. Conclusions Single scrotal incision orchiopexy proved to be an effective technique and is associated with low rates of complications.

  5. A small incision technique facilitates pterygium removal

    Directory of Open Access Journals (Sweden)

    Shu Zhang

    2015-09-01

    Full Text Available AIM: To verify the advantages of an improved protocol for pterygium surgery(small incision removalover a conventional protocol of this surgery.METHODS: Totally 40 primary pterygium cases were divided into two groups(n=20 eachaccording to the protocols: small incision removal versus conventional removal. In our small incision removal, group 1, the pterygium body was cut open with a small incision firstly, through which the conjunctiva was separated from the underlying degenerated Tenon's layer; while in the conventional protocol, group 2, the whole head of pterygium was taken down before the separation. Then the head of pterygium was torn down in our protocol using a forceps instead of cutting it down with a blade, which was facilitated by a special corneal epithelial flap formation method. Surgery time, pain score and corneal wound healing were measured to provide objective comparison of outcome between the two protocols. RESULTS: In the group using small incision removal, the average surgery time was 7.72min(or 48.9%shorter than that of the control group using conventional protocol(PPCONCLUSION: The small incision pterygium removal protocol was easier to perform and resulted in a better outcome than the conventional protocol.

  6. Abdominal incisions in General Surgery: a review | Ajao | Annals of ...

    African Journals Online (AJOL)

    There is this wrong notion that the only standard abdominal incision is the midline incision. Cases have been seen in which an abdominal incision extends from the xyphoid process to the symphysis pubis just to remove a perforated appendix! It is also not unusual to see a groin incision together with a lower abdominal ...

  7. Laparoscopic cholecystectomy with two mini cosmetic incisions.

    Science.gov (United States)

    Tavassoli, Alireza; Noorshafiee, Sajad

    2017-12-18

    Minimally invasive surgery gained popularity between general surgeons especially laparoscopic four-port cholecystectomy. By introducing different methods such as NOTES and SILS, the costs elevated with its cosmetics. We aim to study a new technique of laparoscopic cholecystectomy by two incisions with best cosmetics, and same quality and lower cost as conventional four-port laparoscopic cholecystectomy and make a comparison between them. In a double-blind clinical trial from December 2012 to September 2014, patients with cholelithiasis who presented to general surgery clinic and candidate for laparoscopic cholecystectomy were studied. Half of patients underwent double-incision laparoscopic cholecystectomy and other half underwent conventional four-port laparoscopic cholecystectomy. The mean age and BMI were higher in double-incision and four-port group, respectively, but not statistically different. Also male to female ratio was 6:1 in double-incision group and 9:1 in four-port group, and they were not statistically different. The mean operation time was about 2 min more in double-incision group, but it is trivial to consider a significant difference at level of 5%. The mean pain score (0-10) was significantly lower in double incision group in comparison with four-port group (p < 0.0001). Patients in double incision group reported higher satisfaction and were sooner in return to work than in four-port group (p < 0.0001). It seems that DILS for uncomplicated cholelithiasis is safe. By reducing port number, we succeed in reducing the pain and need for analgesics, reducing hospital staying and sooner return to work. By taking into account using conventional CLS instrument and lowering the hospital charges, it could be a good alternative to SILS.

  8. Comparison of surgically induced astigmatism in various incisions in manual small incision cataract surgery

    Directory of Open Access Journals (Sweden)

    Nidhi Jauhari

    2014-12-01

    Full Text Available AIM:To determine the surgically induced astigmatism (SIA in Straight, Frown and Inverted V shape (Chevron incisions in manual small incision cataract surgery (SICS.METHODS:A prospective cross sectional study was done on a total of 75 patients aged 40y and above with senile cataract. The patients were randomly divided into three groups (25 each. Each group received a particular type of incision (Straight, Frown or Inverted V shape incisions. Manual SICS with intraocular lens (IOL implantation was performed. The patients were compared 4wk post operatively for uncorrected visual acuity (UCVA, best corrected visual acuity (BCVA and SIA. All calculations were performed using the SIA calculator version 2.1, a free software program. The study was analyzed using SPSS version 15.0 statistical analysis software.RESULTS:The study found that 89.5% of patients in Straight incision group, 94.2% in Frown incision group and 95.7% in Inverted V group attained BCVA post-operatively in the range of 6/6 to 6/18. Mean SIA was minimum (-0.88±0.61D×90 degrees with Inverted V incision which was statistically significant.CONCLUSION:Inverted V (Chevron incision gives minimal SIA.

  9. Single incision laparoscopic colorectal resection: Our experience

    Directory of Open Access Journals (Sweden)

    Chinnusamy Palanivelu

    2012-01-01

    Full Text Available Background: A prospective case series of single incision multiport laparoscopic colorectal resections for malignancy using conventional laparoscopic trocars and instruments is described. Materials and Methods: Eleven patients (seven men and four women with colonic or rectal pathology underwent single incision multiport laparoscopic colectomy/rectal resection from July till December 2010. Four trocars were placed in a single transumblical incision. The bowel was mobilized laparoscopically and vessels controlled intracorporeally with either intra or extracorporeal anastomosis. Results: Three patients had carcinoma in the caecum, one in the hepatic flexure, two in the rectosigmoid, one in the descending colon, two in the rectum and two had ulcerative pancolitis (one with high grade dysplasia and another with carcinoma rectum. There was no conversion to standard multiport laparoscopy or open surgery. The median age was 52 years (range 24-78 years. The average operating time was 130 min (range 90-210 min. The average incision length was 3.2 cm (2.5-4.0 cm. There were no postoperative complications. The average length of stay was 4.5 days (range 3-8 days. Histopathology showed adequate proximal and distal resection margins with an average lymph node yield of 25 nodes (range 16-30 nodes. Conclusion: Single incision multiport laparoscopic colorectal surgery for malignancy is feasible without extra cost or specialized ports/instrumentation. It does not compromise the oncological radicality of resection. Short-term results are encouraging. Long-term results are awaited.

  10. Comparison of primary total hip replacements performed with a standard incision or a mini-incision.

    Science.gov (United States)

    Woolson, Steven T; Mow, Christopher S; Syquia, Jose Fernando; Lannin, John V; Schurman, David J

    2004-07-01

    Primary total hip replacement performed through an incision that is a minimally invasive technique. Proponents have claimed that mini-incision techniques reduce blood loss, transfusion requirements, postoperative pain, and the length of the hospital stay compared with standard techniques through a longer incision. However, we are aware of no well-designed comparison study that supports these claims. The purpose of the present study was to compare the short-term results of a mini-incision with a standard incision technique for total hip replacement. A consecutive series of patients who underwent 135 primary unilateral total hip replacements (fifty with use of a mini-incision [a standard incision) by three surgeons at one hospital were studied. Each surgeon selected patients to have a mini-incision procedure and performed a standard approach in the remaining patients. A posterior approach was used for all procedures. In-hospital data were collected retrospectively, and the initial postoperative radiographs were analyzed. Because of the selection process, the patients who had a mini-incision had both a significantly lower average body-mass index (p = 0.008) and a lower average score on the American Society of Anesthesiologists rating (p = 0.006), indicating that they were thinner and healthier than the patients who had a standard incision. With the numbers of patients available, no significant differences were found between the groups with respect to the average surgical time, intraoperative blood loss, in-hospital transfusion rate, length of hospital stay, or the patients' disposition after discharge. The mini-incision group was found to have a significantly higher risk of a wound complication (p = 0.02), a higher percentage of acetabular component malposition (p = 0.04), and poor fit and fill of femoral components inserted without cement (p = 0.0036). There was no evidence that the mini-incision technique resulted in less bleeding or less trauma to the soft tissues

  11. Small Incision Cataract Surgery (SICS with Clear Corneal Incision and SICS with Scleral Incision – A Comparative Study

    Directory of Open Access Journals (Sweden)

    Md Shafiqul Alam

    2014-01-01

    Full Text Available Background: Age related cataract is the leading cause of blindness and visual impairment throughout the world. With the advent of microsurgical facilities simple cataract extraction surgery has been replaced by small incision cataract surgery (SICS with posterior chamber intra ocular lens implant, which can be done either with clear corneal incision or scleral incision. Objective: To compare the post operative visual outcome in these two procedures of cataract surgery. Materials and method: This comparative study was carried out in the department of Ophthalmology, Delta Medical College & Hospital, Dhaka, Bangladesh, during the period of January 2010 to December 2012. Total 60 subjects indicated for age related cataract surgery irrespective of sex with the age range of 40-80 years with predefined inclusion and exclusion criteria were enrolled in the study. Subjects were randomly and equally distributed in 2 groups; Group A for SICS with clear corneal incision and group B for SICS with scleral incision. Post operative visual out come was evaluated by determining visual acuity and astigmatism in different occasions and was compared between groups. Statistical analysis was done by SPSS for windows version12. Results: The highest age incidence (43.3% was found between 61 to 70 years of age group. Among study subjects 40 were male and 20 were female. Preoperative visual acuity and astigmatism were evenly distributed between groups. Regarding postoperative unaided visual outcome, 6/12 or better visual acuity was found in 19.98% cases in group A and 39.6% cases in group B at 1st week. At 6th week 6/6 vision was found in 36.3% in Group A and 56.1% in Group B and 46.2% in group A and 66% in group B without and with correction respectively. With refractive correction, 6/6 vision was attained in 60% subjects of group A and 86.67% of group B at 8th week. Post operative visual acuity was statistically significant in all occasions. Postoperative astigmatism of

  12. [EFFECTIVENESS OF ADVANCED SKIN FLAP AND V-SHAPED VENTRAL INCISION ALONG THE ROOT OF PENILE SHAFT FOR CONCEALED PENIS].

    Science.gov (United States)

    Lin, Junshan; Li, Dumiao; Zhang, Jianxing; Wu, Qiang; Xu, Yali; Lin, Li

    2015-09-01

    To investigate effectiveness of advanced skin flap and V-shaped ventral incision along the root of penile shaft for concealed penis in children. Between July 2007 and January 2015, 121 boys with concealed penis were treated with advanced skin flap and V-shaped ventral incision along the root of penile shaft. The age varied from 18 months to 13 years (mean, 7.2 years). Repair was based on a vertical incision in median raphe, complete degloving of penis and tacking its base to the dermis of the skin. Advanced skin flap and a V-shaped ventral incision along the root of penile shaft were used to cover the penile shaft. The operation time ranged from 60 to 100 minutes (mean, 75 minutes). Disruption of wound occurred in 1 case, and was cured after dressing change; and primary healing of incision was obtained in the others. The follow-up period ranged from 3 months to 7 years (median, 24 months). All patients achieved good to excellent cosmetic results with a low incidence of complications. The results were satisfactory in exposure of penis and prepuce appearance. No obvious scar was observed. The penis had similar appearance to that after prepuce circumcision. A combination of advanced skin flap and V-shaped ventral incision along the root of penile shaft is a simple, safe, and effective procedure for concealed penis with a similar appearance result to the prepuce circumcision.

  13. Generating passive NIR images from active LIDAR

    Science.gov (United States)

    Hagstrom, Shea; Broadwater, Joshua

    2016-05-01

    Many modern LIDAR platforms contain an integrated RGB camera for capturing contextual imagery. However, these RGB cameras do not collect a near-infrared (NIR) color channel, omitting information useful for many analytical purposes. This raises the question of whether LIDAR data, collected in the NIR, can be used as a substitute for an actual NIR image in this situation. Generating a LIDAR-based NIR image is potentially useful in situations where another source of NIR, such as satellite imagery, is not available. LIDAR is an active sensing system that operates very differently from a passive system, and thus requires additional processing and calibration to approximate the output of a passive instrument. We examine methods of approximating passive NIR images from LIDAR for real-world datasets, and assess differences with true NIR images.

  14. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  15. DOES TUBULARIZED INCISED PLATE URETHROPLASTY FIT ...

    African Journals Online (AJOL)

    Objective To evaluate prospectively our experience using tubularized incised plate (TIP) urethroplasty in primary and repeat penile shaft hypospadias. Patients and Methods Thirty-two boys with penile shaft hypospadias were selected to undergo TIP procedure. Their age ranged from 22 months to 9 years. Twenty-two cases ...

  16. Single scrotal incision orchidopexy for palpable undescended

    International Nuclear Information System (INIS)

    Ahmad, A.; Safdar, C.A.; Yasir, U.; Rasool, N.; Kanwal, S.; Boota, M.; Rehman, J.U.

    2014-01-01

    To retrospectively asses the results of single scrotal incision orchidopexy (SSIO) performed at our centre with ligation of the patent processus vaginalis in children having palpable undescended testes (UDT). Study Design: Quasi-experimental with retrospective data. Place and Duration of Study: Department of Paediatric surgery Military Hospital Rawalpindi, from April 2007 to December 2011. Patients and Methods: After making a single transverse incision at superior scrotal border, the testis was identified; gubernaculums and the sac were dissected to the highest level and divided. The testis was placed into the scrotum and fixed to the scrotal fascia/skin. All patients were assessed at 2 weeks, 2 months and 6 months post operatively, and then yearly. Results: A total of 38 orchidopexies were performed in 33 patients. The patients age ranged from 14 months to 7 years (mean:2.1 years). Bilateral UDT were found in 5 patients (15.1%). Operative time ranged from 20 to 45 minutes (mean: 36 minutes). The single scrotal incision technique was successful in all 38 cases (100%). All testes were easily fixed in the scrotum. Two patients (5.2%) developed scrotal haematoma and one patient (2.6%) developed stitch abscess. All showed good an atomical and cosmetic results up to a minimum of six months of follow-up. Conclusion: Single scrotal incision orchidopexy for palpable undescended testis is a simple and safe technique. It has shown to consume shorter time and give good cosmetic results. (author)

  17. DNA-repair measurements by use of the modified comet assay

    DEFF Research Database (Denmark)

    Godschalk, Roger W L; Ersson, Clara; Riso, Patrizia

    2013-01-01

    The measurement of DNA-repair activity by extracts from cells or tissues by means of the single-cell gel electrophoresis (comet) assay has a high potential to become widely used in biomonitoring studies. We assessed the inter-laboratory variation in reported values of DNA-repair activity...... on substrate cells that had been incubated with Ro19-8022 plus light to generate oxidatively damaged DNA. Eight laboratories assessed the DNA-repair activity of three cell lines (i.e. one epithelial and two fibroblast cell lines), starting with cell pellets or with cell extracts provided by the coordinating...... laboratory. There was a large inter-laboratory variation, as evidenced by the range in the mean level of repair incisions between the laboratory with the lowest (0.002incisions/10(6)bp) and highest (0.988incisions/10(6)bp) incision activity. Nevertheless, six out of eight laboratories reported the same cell...

  18. The Antinociceptive Effect of Light-Emitting Diode Irradiation on Incised Wounds Is Correlated with Changes in Cyclooxygenase 2 Activity, Prostaglandin E2, and Proinflammatory Cytokines

    Directory of Open Access Journals (Sweden)

    Yuan-Yi Chia

    2017-01-01

    Full Text Available Background. Light-emitting diode (LED phototherapy has been reported to relieve pain and enhance tissue repair through several mechanisms. However, the analgesic effect of LED on incised wounds has never been examined. Objectives. We examined the analgesic effect of LED therapy on incision pain and the changes in cyclooxygenase 2 (COX-2, prostaglandin E2 (PGE2, and the proinflammatory cytokines interleukin 6 (IL-6, IL-1β, and tumor necrosis factor α (TNF-α. Methods. Rats received LED therapy on incised skin 6 days before incision (L-I group or 6 days after incision (I-L group or from 3 days before incision to 3 days after incision (L-I-L group. Behavioral tests and analysis of skin tissue were performed after LED therapy. Results. LED therapy attenuated the decrease in thermal withdrawal latency in all the irradiated groups and the decrease in the mechanical withdrawal threshold in the L-I group only. The expression levels of COX-2, PGE2, and IL-6 were significantly decreased in the three LED-treated groups, whereas IL-1β and TNF-α were significantly decreased only in the L-I group compared with their levels in the I groups (p<0.05. Conclusions. LED therapy provides an analgesic effect and modifies the expression of COX-2, PGE2, and proinflammatory cytokines in incised skin.

  19. Radiological findings after endoscopic incision of ureterocele

    International Nuclear Information System (INIS)

    Cheon, Jung Eun; Kim, In One; Seok, Eul Hye; Cha, Joo Hee; Choi, Gook Myung; Kim, Woo Sun; Yeon, Kyung Mo; Kim, Kwang Myung; Choi, Hwang; Cheon, Jung Eun; Seok, Eul Hye; Cha, Joo Hee; Choi, Guk Myung

    2001-01-01

    Endoscopic incision of ureterocele is considered a simple and safe method for decompression of urinary tract obstruction above ureterocele. The purpose of this study was to evaluate the radiological findings after endoscopic incision of ureterocele. We retrospectively reviewed the radiological findings (ultrasonography (US), intravenous urography, and voiding cystourethrography(VCU)) in 16 patients with ureterocele who underwent endoscopic incision (mean age at surgery, 15 months; M:F 3:13; 18 ureteroceles). According to the postoperative results, treatment was classified as successful when medical treatment was still required, and second operation when additional surgical treatment was required. Postoperative US (n=10) showed that in all patients, urinary tract obstruction was relieved: the kidney parenchima was thicker and the ureterocele was smaller. Intravenous urography (n=8), demonstrated that in all patients, urinary tract obstruction and the excretory function of the kidney had improved. Postoperative VCU indicated that in 92% of patients (12 of 13), endoscopic incision of the ureterocele led to vesicoureteral reflux(VUR). Of these twelve, seven (58%) showed VUR of more than grade 3, while newly developed VUR was seen in five of eight patients (63%) who had preoperative VCU. Surgery was successful in four patients (25%), partially successful in three (19%), and a second operation-on account of recurrent urinary tract infection and VUR of more than grase 3 during the follow-up period-was required by nine (56%). Although endoscopic incision of a ureterocele is a useful way of relieving urinary tract obstruction, an ensuing complication may be VUR. Postoperative US and intravenous urography should be used to evaluate parenchymal change in the kidney and improvement of uronary tract obstructon, while to assess the extend of VUR during the follow-up period , postoperative VCU is required

  20. COMPARISON OF POSTOP SIA IN MSICS WITH STRAIGHT INCISION VERSUS FROWN INCISION

    Directory of Open Access Journals (Sweden)

    Shayana Bhumbla

    2017-05-01

    Full Text Available BACKGROUND Surgically-Induced Astigmatism (SIA is one of the commonest causes of poor postoperative vision even after uneventful cataract surgery. Recent advances have led to a newer concept of “refractive cataract surgery.” The aim of the study is to study the comparison of postop SIA in Manual Small Incision Cataract Surgery (MSICS with straight versus frown incision. MATERIALS AND METHODS 50 patients of cataract were divided into 2 groups (25 each - group A underwent MSICS with 6 mm straight incision, group B underwent MSICS with 6 mm frown incision. BCVA, keratometry readings were recorded with auto kerato-refractometer preop, at 1 week, 1 month, 3 months and SIA was calculated with SIA calculator version 2.1, a free software program. RESULTS Mean SIA in group A and B were - 1.14D versus 0.92D at 1 week; 1.26D versus 0.97D at 1 month; 1.29D versus 0.95D at 3 months. The difference was statistically significant at each follow up visit (p<0.05. CONCLUSION Frown incision gives lesser SIA than straight incision in MSICS.

  1. DNA repair

    International Nuclear Information System (INIS)

    Setlow, R.

    1978-01-01

    Some topics discussed are as follows: difficulty in extrapolating data from E. coli to mammalian systems; mutations caused by UV-induced changes in DNA; mutants deficient in excision repair; other postreplication mechanisms; kinds of excision repair systems; detection of repair by biochemical or biophysical means; human mutants deficient in repair; mutagenic effects of UV on XP cells; and detection of UV-repair defects among XP individuals

  2. Analysis of single-incision versus dual-incision fasciotomy for tibial fractures with acute compartment syndrome.

    Science.gov (United States)

    Bible, Jesse E; McClure, D Jake; Mir, Hassan R

    2013-11-01

    To analyze the rate of postoperative infection and nonunion after tibial fractures in patients treated for acute compartment syndrome (ACS) using (1) single-incision versus (2) dual-incision fasciotomy technique. Retrospective. Level I trauma center. Review of all adult tibial fractures operatively treated (n = 2756) over a 12-year period identified 175 patients with concurrent ACS requiring fasciotomy. Of 60 patients treated with intramedullary nails, 36 patients had single-incision fasciotomy and 24 had dual-incision fasciotomy. Of 81 patients treated with plate fixation, 59 patients had single-incision fasciotomy and 22 had dual-incision fasciotomy. Tibial fixation with fasciotomy for ACS. Occurrence of postoperative infection and nonunion. Both fasciotomy groups were similar across recorded patient and treatment characteristics. Need for skin graft was similar between fasciotomy groups. For patients treated with intramedullary nail (n = 60), 1 infection (2.8%) occurred in single-incision group versus 2 (8.3%) in dual-incision group (P = 0.558). Seven nonunions (19.4%) occurred in single-incision group versus 3 (12.5%) in dual-incision group (P = 0.726). For plate fixation patients (n = 81), 15 infections (25.4%) occurred with single-incision fasciotomy versus 5 infections (22.7%) with dual-incision fasciotomy (P = 1.000). Seven nonunions (11.9%) occurred with single-incision group versus 4 nonunions (18.2%) with dual-incision group (P = 0.479). This is the first study to compare a single-incision fasciotomy technique to a dual-incision technique in the setting of tibial fractures with ACS, with similar infection and nonunion rates with either technique. The choice of fasciotomy technique can be based on surgeon experience or patient condition as opposed to a suspected elevated infection or nonunion risk with either technique. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  3. Drainage basins and channel incision on Mars

    Science.gov (United States)

    Aharonson, Oded; Zuber, Maria T.; Rothman, Daniel H.; Schorghofer, Norbert; Whipple, Kelin X.

    2002-02-01

    Measurements acquired by the Mars Orbiter Laser Altimeter on board the Mars Global Surveyor indicate that large drainage systems on Mars have geomorphic characteristics inconsistent with prolonged erosion by surface runoff. We find the topography has not evolved to an expected equilibrium terrain form, even in areas where runoff incision has been previously interpreted. By analogy with terrestrial examples, groundwater sapping may have played an important role in the incision. Longitudinally flat floor segments may provide a direct indication of lithologic layers in the bedrock, altering subsurface hydrology. However, it is unlikely that floor levels are entirely due to inherited structures due to their planar cross-cutting relations. These conclusions are based on previously unavailable observations, including extensive piece-wise linear longitudinal profiles, frequent knickpoints, hanging valleys, and small basin concavity exponents.

  4. Primary closure of equine laryngotomy incisions

    DEFF Research Database (Denmark)

    Lindegaard, C.; Karlsson, L.; Ekstrøm, Claus Thorn

    2016-01-01

    The objective was to report healing characteristics and complications after primary closure of equine laryngotomies and analyse factors potentially associated with complications. This retrospective case series of the medical records of horses (n = 180) undergoing laryngoplasty and laryngotomy...... after primary closure of equine laryngotomy incisions are infrequent and considered of minimal severity and can be performed safely when paying careful attention to the closure of the cricothyroid membrane....

  5. Diversity of nitrite reductase genes (nirS) in the denitrifying water column of the coastal Arabian Sea

    Digital Repository Service at National Institute of Oceanography (India)

    Jayakumar, D.A.; Francis, C.A.; Naqvi, S.W.A.; Ward, B.B.

    are investigated. Nitrite reduction to nitric oxide is the key step in the denitrification pathway, and is catalyzed by the enzyme nitrite reductase, which is encoded by the genes nirS and nirK. The diversity and distribution of nirS genes in relation to nitrite...

  6. Right Kocher’s incision: a feasible and effective incision for right hemicolectomy: a retrospective study

    Directory of Open Access Journals (Sweden)

    Theodosopoulos Theodosios

    2012-06-01

    Full Text Available Abstract Background The choice of surgical incision is determined by access to the surgical field, particularly when an oncological resection is required. Special consideration is also given to other factors, such as postoperative pain and its sequelae, fewer complications in the early postoperative period and a lower occurrence of incisional hernias. The purpose of this study is to compare the right Kocher’s and the midline incision, for patients undergoing right hemicolectomy, by focusing on short- and longterm results. Methods Between 1995 and 2009, hospital records for 213 patients that had undergone a right hemicolectomy for a right- sided adenocarcinoma were retrospectively studied. 113 patients had been operated via a Kocher’s and 100 via a midline incision. Demographic details, operative data (explorative access to the peritoneal cavity, time of operation, recovery parameters (time with IV analgesic medication, time to first oral fluid intake, time to first solid meal, time to discharge, and oncological parameters (lymph node harvest, TNM stage and resection margins were analyzed. Postoperative complications were also recorded. The two groups were retrospectively well matched with respect to demographic parameters and oncological status of the tumor. Results The median length of the midline incision was slightly longer (12 vs. 10 cm, p  Conclusions The Kocher’s incision approach for right- sided colon cancer is technically feasible, safe and overall very well tolerated. It can achieve the same standards of tumor resection and surgical field accessibility as the midline approach, while reducing postoperative recovery.

  7. Hypospadias repair

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003000.htm Hypospadias repair To use the sharing features on this page, please enable JavaScript. Hypospadias repair is surgery to correct a defect in ...

  8. Greenhouse cooling by NIR-reflection

    NARCIS (Netherlands)

    Hemming, S.; Kempkes, F.; Braak, van der N.; Dueck, T.A.; Marissen, A.

    2007-01-01

    Wageningen UR investigated the potential of several NIR-filtering methods to be applied in horticulture. In this paper the analysis of the optical properties of available NIR-filtering materials is given including a calculation method to quantify the energy reduction under these materials and to

  9. Present status of NIRS ECR ion sources

    NARCIS (Netherlands)

    Muramatsu, M.; Kitagawa, A.; Iwata, Y.; Yamamoto, K.; Ogawa, H.; Hojo, S.; Sakamoto, Y.; Honma, T.; Takasugi, W.; Wakaisami, M.; Yoshida, Y.; Kubo, T.; Kato, Y.; Biri, S.; Drentje, A. G.

    Four ECR ion sources have been operated in National Institute of Radiological Sciences (NIRS). Two ECR ion sources supply various ion species for the Heavy Ion Medical Accelerator in Chiba (HIMAC). The 10GHz NIRS-ECR ion source mainly produces C2+ ions for the heavy-ion therapy. Ions of Si, Ar, Fe,

  10. Large myelomeningocele repair

    Directory of Open Access Journals (Sweden)

    Farideh Nejat

    2011-01-01

    Full Text Available Background: Wound closure is accomplished in most cases of myelomeningocele (MMC by undermining of the skin edges surrounding the defect. However, large defects cannot be closed reliably by this simple technique. Due to the technical challenge associated with large MMC, surgeons have devised different methods for repairing large defects. In this paper, we report our experience of managing large defects, which we believe bears a direct relationship to decrease the incidence of wound complications. Materials and Methods: Forty children with large MMCs underwent surgical repair and represent our experience. We recommend using all hairy skin around the defect as a way to decrease the tension on the edges of the wound and the possible subsequent necrosis. It is our experience that vertical incision on one or two flanks parallel to the midline can decrease the tension of the wound. Moreover, ventriculo-peritoneal shunting for children who developed hydrocephalus was performed simultaneously, which constitutes another recommendation for preventing fluid collection and build up of pressure on the wound. Results: Patients in this study were in the age range of 2 days to 8 years. The most common location of MMC was in the thoracolumbar area. All but four patients had severe weakness in lower extremities. We used as much hairy skin around the MMC sac as possible in all cases. Vertical incisions on one or both flanks and simultaneous shunt procedure were performed in 36 patients. We treated children with large MMC defects with acceptable tension-free closure. Nonetheless, three patients developed superficial skin infection and partial wound dehiscence, and they were managed conservatively. Conclusions: We recommend using all hairy skin around the MMC defect for closure of large defects. In cases that were expected to be at a higher risk to develop dehiscence release incisions on one or two flanks towards the fascia were found to be useful. Simultaneous

  11. Small-incision lenticule extraction (SMILE)

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    2016-01-01

    PURPOSE: To study the outcomes of small-incision lenticule extraction (SMILE) for treatment of myopia and myopic astigmatism. METHODS: Retrospective study of patients treated for myopia or myopic astigmatism with SMILE, using a VisuMax(®) femtosecond laser (Carl Zeiss Meditec, Jena, Germany...... surgery was 0.07 ± 0.03 (logMAR). However, 12 eyes (1.6 %) lost 2 or more lines of CDVA from before surgery to 3 months postoperatively. Simultaneous treatment of up to 3.00 D of astigmatism was not associated with less predictable refractive outcomes. CONCLUSIONS: In the short term, SMILE seemed...

  12. The longitudinal epineural incision and complete nerve transection method for modeling sciatic nerve injury

    Directory of Open Access Journals (Sweden)

    Xing-long Cheng

    2015-01-01

    Full Text Available Injury severity, operative technique and nerve regeneration are important factors to consider when constructing a model of peripheral nerve injury. Here, we present a novel peripheral nerve injury model and compare it with the complete sciatic nerve transection method. In the experimental group, under a microscope, a 3-mm longitudinal incision was made in the epineurium of the sciatic nerve to reveal the nerve fibers, which were then transected. The small, longitudinal incision in the epineurium was then sutured closed, requiring no stump anastomosis. In the control group, the sciatic nerve was completely transected, and the epineurium was repaired by anastomosis. At 2 and 4 weeks after surgery, Wallerian degeneration was observed in both groups. In the experimental group, at 8 and 12 weeks after surgery, distinct medullary nerve fibers and axons were observed in the injured sciatic nerve. Regular, dense myelin sheaths were visible, as well as some scarring. By 12 weeks, the myelin sheaths were normal and intact, and a tight lamellar structure was observed. Functionally, limb movement and nerve conduction recovered in the injured region between 4 and 12 weeks. The present results demonstrate that longitudinal epineural incision with nerve transection can stably replicate a model of Sunderland grade IV peripheral nerve injury. Compared with the complete sciatic nerve transection model, our method reduced the difficulties of micromanipulation and surgery time, and resulted in good stump restoration, nerve regeneration, and functional recovery.

  13. Single-incision laparoscopic bariatric surgery

    Directory of Open Access Journals (Sweden)

    Huang Chih-Kun

    2011-01-01

    Full Text Available Background: Bariatric surgery has been established as the best option of treatment for morbid obesity. In recent years single-incision laparoscopic surgery (SILS has emerged as another modality of carrying out the bariatric procedures. While SILS represents an advance, its application in morbid obesity at present is limited. In this article, we review the technique and results of SILS in bariatric surgery. Methods: The PubMed database was searched and totally 11 series reporting SILS in bariatric surgery were identified and analyzed. The case reports were excluded. Since 2008, 114 morbidly obese patients receiving SILS bariatric surgeries were reported. Results: The procedures performed included SILS gastric banding, sleeve gastrectomy and gastric bypass. No mortality was reported in the literatures. Sixteen patients (14.05% needed an additional incision for a liver retractor, a trocar or for conversion. Only one complication of wound infection was reported in these series. All the surgeons reported that the patients were highly satisfied with the scar. Conclusion: Because of abundant visceral and subcutaneous fat and multiple comorbidities in morbid obesity, it is more challenging for surgeons to perform the procedures with SILS. It is clear that extensive development of new instruments and technical aspects of these procedures as well as randomized studies to compare them with traditional laparoscopy are essential before these procedures can be utilized in day-to-day clinical practice.

  14. Two-Step Incision for Periarterial Sympathectomy of the Hand.

    Science.gov (United States)

    Jeon, Seung Bae; Ahn, Hee Chang; Ahn, Yong Su; Choi, Matthew Seung Suk

    2015-11-01

    Surgical scars on the palmar surface of the hand may lead to functional and also aesthetic and psychological consequences. The objective of this study was to introduce a new incision technique for periarterial sympathectomy of the hand and to compare the results of the new two-step incision technique with those of a Koman incision by using an objective questionnaire. A total of 40 patients (17 men and 23 women) with intractable Raynaud's disease or syndrome underwent surgery in our hospital, conducted by a single surgeon, between January 2008 and January 2013. Patients who had undergone extended sympathectomy or vessel graft were excluded. Clinical evaluation of postoperative scars was performed in both groups one year after surgery using the patient and observer scar assessment scale (POSAS) and the Wake Forest University rating scale. The total patient score was 8.59 (range, 6-15) in the two-step incision group and 9.62 (range, 7-18) in the Koman incision group. A significant difference was found between the groups in the total PS score (P-value=0.034) but not in the total observer score. Our analysis found no significant difference in preoperative and postoperative Wake Forest University rating scale scores between the two-step and Koman incision groups. The time required for recovery prior to returning to work after surgery was shorter in the two-step incision group, with a mean of 29.48 days in the two-step incision group and 34.15 days in the Koman incision group (P=0.03). Compared to the Koman incision, the new two-step incision technique provides better aesthetic results, similar symptom improvement, and a reduction in the recovery time required before returning to work. Furthermore, this incision allows the surgeon to access a wide surgical field and a sufficient exposure of anatomical structures.

  15. Current Status of Single-incision Laparoscopic Surgery

    DEFF Research Database (Denmark)

    Ahmed, Irfan; Ciancio, Fabio; Ferrara, Vincenzo

    2012-01-01

    Recent advances in minimally invasive surgery have centered on reducing the number of incisions required, which has led to the development of the single-incision laparoscopic technique. A panel of European single-incision laparoscopy experts met to discuss the current status of, and the future ex...... to be published to confirm its value. An ideal training route for surgeons who are adopting the technique was agreed upon, as was the need for a single, large clinical registry of data....

  16. Two-Step Incision for Periarterial Sympathectomy of the Hand

    Directory of Open Access Journals (Sweden)

    Seung Bae Jeon

    2015-11-01

    Full Text Available BackgroundSurgical scars on the palmar surface of the hand may lead to functional and also aesthetic and psychological consequences. The objective of this study was to introduce a new incision technique for periarterial sympathectomy of the hand and to compare the results of the new two-step incision technique with those of a Koman incision by using an objective questionnaire.MethodsA total of 40 patients (17 men and 23 women with intractable Raynaud's disease or syndrome underwent surgery in our hospital, conducted by a single surgeon, between January 2008 and January 2013. Patients who had undergone extended sympathectomy or vessel graft were excluded. Clinical evaluation of postoperative scars was performed in both groups one year after surgery using the patient and observer scar assessment scale (POSAS and the Wake Forest University rating scale.ResultsThe total patient score was 8.59 (range, 6-15 in the two-step incision group and 9.62 (range, 7-18 in the Koman incision group. A significant difference was found between the groups in the total PS score (P-value=0.034 but not in the total observer score. Our analysis found no significant difference in preoperative and postoperative Wake Forest University rating scale scores between the two-step and Koman incision groups. The time required for recovery prior to returning to work after surgery was shorter in the two-step incision group, with a mean of 29.48 days in the two-step incision group and 34.15 days in the Koman incision group (P=0.03.ConclusionsCompared to the Koman incision, the new two-step incision technique provides better aesthetic results, similar symptom improvement, and a reduction in the recovery time required before returning to work. Furthermore, this incision allows the surgeon to access a wide surgical field and a sufficient exposure of anatomical structures.

  17. Sediment denitrifier community composition and nirS gene expression investigated with functional gene microarrays

    DEFF Research Database (Denmark)

    Francis, C.A.; Jackson, G.A.; Ward, B.B.

    2008-01-01

    A functional gene microarray was used to investigate denitrifier community composition and nitrite reductase (nirS) gene expression in sediments along the estuarine gradient in Chesapeake Bay, USA. The nirS oligonucleotide probe set was designed to represent a sequence database containing 539...... Chesapeake Bay clones, as well as sequences from many other environments. Greatest nirS diversity was detected at the freshwater station at the head of the bay and least diversity at the higher salinity station near the mouth of the Bay. The most common OTUs from the sequence database were detected...... on the array with high signal strength in most samples. One of the most abundant OTUs, CB2-S-138, was identified as dominant at the mid-bay site by both microarray and quantitative PCR assays, but it comprised a much smaller fraction of the assemblage in the north and south bay samples. cDNA (transcribed from...

  18. Meningocele repair

    Science.gov (United States)

    ... is surgery to repair birth defects of the spine and spinal membranes. Meningocele and myelomeningocele are types of spina bifida . Description For both meningoceles and myelomeningoceles, the surgeon ...

  19. Hypospadias and concomitant undescended testis: Comparison of no skin incision with inguinal and scrotal skin incision orchiopexy.

    Science.gov (United States)

    Sabetkish, Shabnam; Kajbafzadeh, Abdol-Mohammad; Sabetkish, Nastaran

    2015-10-01

    To present the feasibility of no skin incision orchiopexy in children with concomitant hypospadias and undescended testis (UDT) by a single subcoronal incision technique. To introduce the creation of subdartos muscle scrotal pouch with no scrotal skin incision. From one thousand and twenty-one children with hypospadias, 61 patients presented with concomitant palpable UDT and hypospadias. In group I (N = 34) single subcoronal incision with no scrotal skin incision was applied. In group II (N = 27), multi-incision technique was applied for classical orchiopexy and hypospadias surgery. For hypospadias reconstruction, all patients had classical subcoronal and para urethral plate incision with penile skin degloving according to the location of urethral meatus. Early and late complications, surgical time, hospital stay, and cosmetic results were recorded. Children with unilateral UDT and hypospadias had one incision in group I and three skin incisions in group II. Patients with bilateral UDT had one incision in group I and five skin incisions in group II. The operation time was significantly shorter in group I (93 ± 11 min) compared with group II (138 ± 17 min) (P = 0.03). Both groups were operated as day care basis; however, the hospital stay was slightly longer in group II (group I = 12 ± 2 h, vs group II = 16 ± 3 h) (P = 0.07). All testes were satisfactorily positioned into the bottom of the scrotum without development of any testicular atrophy. Single subcoronal penile skin incision is a feasible, safe, and cosmetically satisfactory technique in patients with hypospadias and concomitant UDT. Reduced postoperative pain, better objective cosmetic results, shorter operative time and comfortable post-operative period are the most significant advantages of this approach. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  20. Lateral Nail Fold Incision Technique for Venous Anastomosis in Fingertip Replantation.

    Science.gov (United States)

    Jeon, Byung-Joon; Yang, Jae-Won; Roh, Si Young; Ki, Sae Hwi; Lee, Dong Chul; Kim, Jin Soo

    2016-01-01

    Successful venous anastomosis is one of the most important factors in fingertip replantation. Volar veins in the fingertip course proximally in a random pattern, which makes it difficult to find out the exact locations. Although dorsal veins in the lateral nail fold have constant location and adequate diameter for anastomosis, they have been known as hard to dissect from the immobile subcutaneous tissue. The authors present a new lateral nail fold incision technique for venous anastomosis in the fingertip amputations. From February 2010 to October 2010, 9 replantations using the new incision and venous anastomosis technique were performed in 9 patients. The levels of amputations were from the nail base to half of the nail bed. After repairing the proper digital arteries, a skin incision was made along the junction between the lateral nail fold and nail bed. Careful dissection was performed to isolate the veins in the lateral nail fold. After evaluation of the suitability of the vessel, venous anastomosis was performed. Seven male and 2 female patients were enrolled in this study. Appropriate dorsal veins for anastomosis could be found in 8 of 9 patients. All the replanted stumps survived without venous congestion and following additional procedures. A sizable volar or dorsal vein could not be found in 1 patient. The salvage technique was required in this patient. Dorsal veins in the lateral nail fold can be found easily because of the constant anatomical location. The new incision on the lateral nail fold provides not only sufficient operative field for anastomosis but also additional opportunity of successful venous anastomosis in the selected cases. The authors, therefore, propose this technique as an effective method for an alternative venous anastomosis in the zone I replantation.

  1. Intern's Experiences with Episiotomy and its Repair | Nzeribe ...

    African Journals Online (AJOL)

    Background: Episiotomy ‑an incision of the perineum at the time of vaginal delivery is a common obstetric procedure. If the repair is inadequately done, it may leave the woman suffering from perineal pain and other long term conditions with serious impact on the woman's health and social wellbeing. The importance of skill ...

  2. Human DNA repair and recombination genes

    International Nuclear Information System (INIS)

    Thompson, L.H.; Weber, C.A.; Jones, N.J.

    1988-09-01

    Several genes involved in mammalian DNA repair pathways were identified by complementation analysis and chromosomal mapping based on hybrid cells. Eight complementation groups of rodent mutants defective in the repair of uv radiation damage are now identified. At least seven of these genes are probably essential for repair and at least six of them control the incision step. The many genes required for repair of DNA cross-linking damage show overlap with those involved in the repair of uv damage, but some of these genes appear to be unique for cross-link repair. Two genes residing on human chromosome 19 were cloned from genomic transformants using a cosmid vector, and near full-length cDNA clones of each gene were isolated and sequenced. Gene ERCC2 efficiently corrects the defect in CHO UV5, a nucleotide excision repair mutant. Gene XRCC1 normalizes repair of strand breaks and the excessive sister chromatid exchange in CHO mutant EM9. ERCC2 shows a remarkable /approximately/52% overall homology at both the amino acid and nucleotide levels with the yeast RAD3 gene. Evidence based on mutation induction frequencies suggests that ERCC2, like RAD3, might also be an essential gene for viability. 100 refs., 4 tabs

  3. Pear quality characteristics by Vis / NIR spectroscopy.

    Science.gov (United States)

    Machado, Nicácia P; Fachinello, José C; Galarça, Simone P; Betemps, Débora L; Pasa, Mateus S; Schmitz, Juliano D

    2012-09-01

    Recently, non-destructive techniques such as the Vis / NIR spectroscopy have been used to evaluate the characteristics of maturation and quality of pears. The study aims to validate the readings by the Vis / NIR spectroscopy as a non-destructive way to assess the qualitative characteristics of pear cultivars 'Williams', 'Packams' and 'Carrick', produced according to Brazilian conditions. The experiment was conducted at the Pelotas Federal University, UFPel, in Pelotas / RS, and the instrument used to measure the fruit quality in a non-destructive way was the NIR- Case spectrophotometer (SACMI, Imola, Italy). To determine pears' soluble solids (SS) and pulp firmness (PF), it was established calibration equations for each variety studied, done from the evaluations obtained by a non-destructive method (NIR-Case) and a destructive method. Further on, it was tested the performance of these readings by linear regressions. The results were significant for the soluble solids parameter obtained by the Vis / NIR spectroscopy; however, it did not achieve satisfactory results for the pear pulp firmness of these cultivars. It is concluded that the Vis / NIR spectroscopy, using linear regression, allows providing reliable estimates of pears' quality levels, especially for soluble solids.

  4. Single-Incision Laparoscopic Surgery (SILS Assisted Sigma Resection Via Pfannenstiel Incision for Complicated Diverticulitis

    Directory of Open Access Journals (Sweden)

    Arne Dietrich

    2014-02-01

    Results: The operation time ranged from 89 to 280 min. There were no conversions, and no additional trocars were used. The postoperative hospital stay ranged from 5 to 14 days. All patients were discharged without any intraoperative or postoperative complications. Conclusions: SILS sigma or anterior rectum resection for complicated diverticulitis can be performed via a Pfannenstiel incision. This approach provides direct visualization and access into the pelvis as well as the option to benefit from open surgery devices. The Pfannenstiel incision may generally be recommended for the favorable cosmetic effect and the very low rate of incisional hernias, as reported in the literature. [Arch Clin Exp Surg 2014; 3(1.000: 10-15

  5. Diathermy versus Scalpel incision in elective midline laparotomy: A ...

    African Journals Online (AJOL)

    ... two groups with respect to the mean length of hospital stay (p = 0.834). Conclusion: We conclude that diathermy incision in elective midline laparotomy has significant advantages compared with the scalpel because of reduced incision time, less blood loss, reduced early postoperative pain and analgesic requirements.

  6. Temporal versus Superior Limbal Incision: Any difference in visual ...

    African Journals Online (AJOL)

    Dr. C. Pedro-Egbe

    Department of Ophthalmology, University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria. ABSTRACT. Aim: To compare the visual outcome of a superiorly placed limbal incision ..... Roman SJ, Auclin FX, Chong-Sit DA, Ullern MM. Surgically induced astigmatism with superior and temporal incisions in cases of ...

  7. Mini transverse versus longitudinal incision in carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Korkmaz, M.; Cepoglu, M.C.

    2013-01-01

    Objective: To evaluate the effectiveness of mini-transverse compared with mini-longitudinal incision for carpal tunnel release (CTR) with reference to postoperative functional capacity, symptom severity and complication rate. Study Design: Analytical study. Place and Duration of Study: Cumhuriyet University Medical Faculty, Department of Orthopaedics, Tokat State Hospital, Department of Orthopaedics and Medical Park Tokat Hospital, Department of Neurosurgery, from January 2007 to January 2009. Methodology: This study included 93 hands of 79 patients with carpal tunnel syndrome (CTS), which were operated between 2007 and 2009. Patients were divided according to incision types into Group-1 (undergoing mini-longitudinal incision) and Group-2 (undergoing mini-transverse incision). Patients were evaluated initially and at 3 weeks after treatment according to symptom severity and functional status of Boston Questionnaire (BQ). Demographic and clinical data were analyzed and compared statistically between two groups. Results: Statistically significant differences were observed in BQ symptom and functional scores between the pre- and postoperative period (p < 0.0001). BQ symptom and functional scores at postoperative period were better in Group-1 than Group-2 (p = 0.044 and p = 0.023 respectively). The scar hypersensitivity (p = 0.258) and tenderness (p = 1.00) associated with the incision sites were not statistically different. Conclusion: Longitudinal incision is more effective on symptom and functional conditions than transverse incision. However, there was less scar formation with transverse incision. (author)

  8. Transurethral incision of urethral diverticulum in the female

    DEFF Research Database (Denmark)

    Miskowiak, J; Honnens de Lichtenberg, M

    1989-01-01

    A new technique of transurethral incision of urethral diverticulum was successfully used in two women. The method described is safe, simple and shortens operating time.......A new technique of transurethral incision of urethral diverticulum was successfully used in two women. The method described is safe, simple and shortens operating time....

  9. Temporal versus Superior Limbal Incision: Any difference in visual ...

    African Journals Online (AJOL)

    Aim: To compare the visual outcome of a superiorly placed limbal incision with a temporal limbal incision in extracapsular cataract surgery. The main outcome measures are visual acuity and the degree of stigmatism based on refraction. Method: A retrospective non randomized comparative study. Medical records of 40 ...

  10. Keyhole approach for repair of congenital duodenal obstruction.

    Science.gov (United States)

    Kozlov, Y; Novogilov, V; Yurkov, P; Podkamenev, A; Weber, I; Sirkin, N

    2011-03-01

    We report on our experience of repair of congenital duodenal obstruction using a circumumbilical incision. The aim of this report is to describe how a Bianchi approach provides a safe and invisible alternative to transverse abdominal incision for the repair of duodenal atresia. Between January 2005 and December 2009, we treated 13 cases with congenital duodenal obstruction using a circumumbilical incision (Group I) and 14 cases with this condition repaired using a standard transverse right upper abdominal incision (Group II). Surgical procedures included a diamond-shaped duodenoduodenostomy as originally described by Kimura and standard duodenal web excision. The circumumbilical incision utilized at our institution is a classic Bianchi procedure. The 2 groups were compared with regard to patient demographics, operative reports and postoperative outcomes. There were no differences in preoperative parameters such as gestational age, age at surgery, or body weight at operation between the 2 groups. The circumumbilical cohort and transverse incision cohort had similar rates of congenital anomalies (61.54% vs. 64.29%), Kimura diamond-shaped anastomosis (61.54% vs. 64.29%) with only a slight female predominance in Group I. The mean operating time in Group I was 65.0 min while mean duration of the operation in Group II was 64.64 min. The difference between groups was statistically not significant (p>0.05). The mean time to full enteral feeding for patients with an umbilical incision was significantly shorter (p<0.0001) compared to patients with a standard incision (6.92 days vs. 11.86 days). Mean postoperative hospital stay was longer for patients in Group II (19.71 days vs. 12.38 days; p<0.0001). The postoperative course was uneventful for all patients. There were no intra- or postoperative complications. We report on a first series comparing umbilical and transverse right upper abdominal incision for the treatment of congenital duodenal obstruction. Our results suggest

  11. First Canadian experience with robotic single-incision pyeloplasty: Comparison with multi-incision technique.

    Science.gov (United States)

    Law, Jeffrey; Rowe, Neal; Archambault, Jason; Nastis, Sofia; Sener, Alp; Luke, Patrick P

    2016-01-01

    We compared the outcomes of single-incision, robot-assisted laparoscopic pyeloplasty vs. multiple-incision pyeloplasty using the da Vinci robotic system. We reviewed all consecutive robotic pyeloplasties by a single surgeon from January 2011 to August 2015. A total of 30 procedures were performed (16 single:14 multi-port). Two different single-port devices were compared: the GelPort (Applied Medical, Rancho Santa Margarita, CA) and the Intuitive single-site access port (Intuitive Surgical, Sunnyvale, CA). Patient demographics were similar between the two groups. Mean operating time was similar among the single and multi-port groups (225.2 min vs. 198.9 minutes [p=0.33]). There was no significant difference in length of hospital stay in either group (86.2 hr vs. 93.2 hr [p=0.76]). There was no difference in success rates or postoperative complications among groups. Single-port robotic pyeloplasty is non-inferior to multiple-incision robotic surgery in terms of operative times, hospitalization time, success rates, and complications. Verifying these results with larger cohorts is required prior to the wide adoption of this technique. Ongoing objective measurements of cosmesis and patient satisfaction are being evaluated.

  12. Vertical compared with transverse incisions in abdominal surgery

    DEFF Research Database (Denmark)

    Grantcharov, T P; Rosenberg, J

    2001-01-01

    OBJECTIVE: To reach an evidence-based consensus on the relative merits of vertical and transverse laparotomy incisions. DESIGN: Review of all published randomised controlled trials that compared the postoperative complications after the two main types of abdominal incisions, vertical and transverse...... postoperative pain and fewer pulmonary complications. Vertical laparotomy, however, is associated with shorter operating time and better possibilities for extension of the incision. The pooled odds ratio for burst abdomen in the vertical incision group was 2.86 (95% confidence interval 1.72 to 4.73, p = 0.......0001), and regarding late incisional hernia the pooled odds ratio was 1.68 (95% confidence interval 1.10 to 2.57. p = 0.02). CONCLUSIONS: Transverse incisions in abdominal surgery are based on better anatomical and physiological principles. They should be recommended, as the early postoperative period is associated...

  13. Incisive canal deflation for correct implant placement: case report.

    Science.gov (United States)

    Spin-Neto, Rubens; Bedran, Telma Blanca Lombardo; de Paula, Wagner Nunes; de Freitas, Rubens Moreno; de Oliveira Ramalho, Lizeti Toledo; Marcantonio, Elcio

    2009-12-01

    This article is a case report of a patient in whom the prosthetic planning indicated the necessity of an incisive canal deflation for the correct installation of an implant that is to be osseointegrated. In the reopening phase after the bone graft installation, the incisive canal deflation (biopsy of its content) was done and titanium implants were installed with one of them invading the anatomical space occupied previously by the incisive canal. The biopsy analysis showed fragments of the incisive artery and nerve, which are responsible for the anterior upper-tooth pulp, the periodontium vascularization and the innervation. From the anastomosis present along with other structures allied with the absence of teeth in the region, there was no detriment to the patient caused by the deflation. Incisive canal deflation is a viable technique in implantology. It can permit ideal prosthetic planning with no detriment to the patient.

  14. Influence of Incision Location on Transmitter Loss, Healing, Incision Lengths, Suture Retention, and Growth of Juvenile Chinook Salmon

    Energy Technology Data Exchange (ETDEWEB)

    Panther, Jennifer L.; Brown, Richard S.; Gaulke, Greggory L.; Woodley, Christa M.; Deters, Katherine A.

    2010-05-11

    In this study, conducted by Pacific Northwest National Laboratory for the U.S. Army Corps of Engineers, Portland District, we measured differences in survival and growth, incision openness, transmitter loss, wound healing, and erythema among abdominal incisions on the linea alba, lateral and parallel to the linea alba (muscle-cutting), and following the underlying muscle fibers (muscle-sparing). A total of 936 juvenile Chinook salmon were implanted with both Juvenile Salmon Acoustic Tracking System transmitters (0.43 g dry) and passive integrated transponder tags. Fish were held at 12°C (n = 468) or 20°C (n = 468) and examined once weekly over 98 days. We found survival and growth did not differ among incision groups or between temperature treatment groups. Incisions on the linea alba had less openness than muscle-cutting and muscle-sparing incisions during the first 14 days when fish were held at 12°C or 20°C. Transmitter loss was not different among incision locations by day 28 when fish were held at 12°C or 20°C. However, incisions on the linea alba had greater transmitter loss than muscle-cutting and muscle-sparing incisions by day 98 at 12°C. Results for wound closure and erythema differed among temperature groups. Results from our study will be used to improve fish-tagging procedures for future studies using acoustic or radio transmitters.

  15. Cleft Palate Repair Using a Double Opposing Z-Plasty.

    Science.gov (United States)

    Moores, Craig; Shah, Ajul; Steinbacher, Derek M

    2016-07-01

    Cleft palate is a common congenital defect with several described surgical repairs. The most successful treatment modality remains a controversy. The goals of repair focus on achievement of normal speech and optimizing velopharyngeal function while minimizing both fistula formation and facial growth restriction. In this video, the authors demonstrate use of the double opposing Z-plasty technique in the repair of a Veau II type cleft palate. The video demonstrates the marking, incisions, dissection, and repair of the cleft. It also examines the use of von Langenbeck-type relaxing incisions and demonstrates a specific approach to the repair of this particular cleft. The authors believe that the Furlow double opposing Z-plasty with the von Langenbeck relaxing incision can provide the best postoperative outcome by combining the benefits of each individual operation. The Z-plasty technique works to correct the aberrant muscle of the soft palate while increasing the length of the palate. The authors believe that this results in better velopharyngeal function.

  16. Assessment of corneal astigmatism following frown and straight incision forms in sutureless manual small incision cataract surgery

    Directory of Open Access Journals (Sweden)

    Amedo AO

    2016-04-01

    Full Text Available Angela Ofeibea Amedo, Kwadwo Amoah, Nana Yaa Koomson, David Ben Kumah, Eugene Appenteng Osae Department of Optometry and Visual Science, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana Abstract: To investigate which of two tunnel incision forms (frown versus straight in sutureless manual small incision cataract surgery creates more corneal astigmatism. Sixty eyes of 60 patients who had consented to undergo cataract surgery and to partake in this study were followed from baseline through >12-week postoperative period. Values of preoperative and postoperative corneal astigmatism for the 60 eyes, measured with a Bausch and Lomb keratometer, were extracted from the patients’ cataract surgery records. Residual astigmatism was computed as the difference between preoperative and postoperative keratometry readings. Visual acuity was assessed during the preoperative period and at each postoperative visit with a Snellen chart at 6 m. Fifty eyes of 50 patients were successfully followed-up on. Overall, the mean residual astigmatism was 0.75±0.12 diopters. The differences in mean residual astigmatism between the two different incision groups were statistically significant (t [48]=6.33, P<0.05; frown incision group recorded 1.00±0.12 diopters, whereas the straight incision group recorded 0.50±0.12 diopters. No significant difference was observed between male and female groups (t [48]=0.24, P>0.05. Residual corneal astigmatism in the frown incision group was significantly higher than in the straight incision group. Fisher’s exact test did not reveal a significant association between incision forms and visual acuity during the entire postoperative period (P>0.05. Keywords: cataract, residual corneal astigmatism, frown incision, straight incision

  17. Enzymatic repair of uv-irradiated DNA in vitro

    International Nuclear Information System (INIS)

    Hamilton, L.D.; Mahler, I.; Grossman, L.

    1975-01-01

    Excision repair of uv-damaged Bacillus subtilis transforming DNA has been carried out by a sequential enzyme system in vitro. Incision adjacent to the pyrimidine dimer in the DNA strand by correndonuclease II-initiated excision of the damage by the 5' → 3'-directed exonuclease of the Micrococcus luteus DNA polymerase. Reinsertion of nucleotides into the gap in the strand by the DNA polymerase at 10 0 C terminated in a single-strand break which was sealed by a polynucleotide ligase, thereby repairing the DNA strand. This restored biological activity to damaged DNA up to doses resulting in 60 percent inactivation of transforming activity. At higher doses, less repair was achieved, due to the development of double-strand breaks during the in vitro incision and excision steps

  18. Improving NIR snow pit stratigraphy observations by introducing a controlled NIR light source

    Science.gov (United States)

    Dean, J.; Marshall, H.; Rutter, N.; Karlson, A.

    2013-12-01

    Near-infrared (NIR) photography in a prepared snow pit measures mm-/grain-scale variations in snow structure, as reflectivity is strongly dependent on microstructure and grain size at the NIR wavelengths. We explore using a controlled NIR light source to maximize signal to noise ratio and provide uniform incident, diffuse light on the snow pit wall. NIR light fired from the flash is diffused across and reflected by an umbrella onto the snow pit; the lens filter transmits NIR light onto the spectrum-modified sensor of the DSLR camera. Lenses are designed to refract visible light properly, not NIR light, so there must be a correction applied for the subsequent NIR bright spot. To avoid interpolation and debayering algorithms automatically performed by programs like Adobe's Photoshop on the images, the raw data are analyzed directly in MATLAB. NIR image data show a doubling of the amount of light collected in the same time for flash over ambient lighting. Transitions across layer boundaries in the flash-lit image are detailed by higher camera intensity values than ambient-lit images. Curves plotted using median intensity at each depth, normalized to the average profile intensity, show a separation between flash- and ambient-lit images in the upper 10-15 cm; the ambient-lit image curve asymptotically approaches the level of the flash-lit image curve below 15cm. We hypothesize that the difference is caused by additional ambient light penetrating the upper 10-15 cm of the snowpack from above and transmitting through the wall of the snow pit. This indicates that combining NIR ambient and flash photography could be a powerful technique for studying penetration depth of radiation as a function of microstructure and grain size. The NIR flash images do not increase the relative contrast at layer boundaries; however, the flash more than doubles the amount of recorded light and controls layer noise as well as layer boundary transition noise.

  19. Repair of DNA damage in Deinococcus radiodurans

    International Nuclear Information System (INIS)

    Evans, D.M.

    1984-01-01

    The repair of DNA lesions in Deinococcus radiodurans was examined with particular reference to DNA excision repair of ultraviolet light (UV) induced pyrimidine dimers. The characteristics of excision repair via UV endonucleases α and β in vivo varied with respect to (a) the substrate range of the enzymes, (b) the rate of repair of DNA damage (c) the requirement for a protein synthesised in response to DNA damage to attenuate exonuclease action at repairing regions. UV endonuclease α is postulated to incise DNA in a different manner from UV endonuclease β thus defining the method of subsequent repair. Several DNA damage specific endonuclease activities independent of α and β are described. Mutations of the uvsA, uvsF and uvsG genes resulted in an increase in single-strand breaks in response to DNA damage producing uncontrolled DNA degradation. Evidence is presented that these genes have a role in limiting the access of UV endonuclease β to DNA lesions. uvsF and uvsG are also shown to be linked to the mtoA gene. Mutation of uvsH and reo-1 produces further distinct phenotypes which are discussed. An overall model of excision repair of DNA damage in Deinococcus radiodurans is presented. (author)

  20. Hydrocele repair

    Science.gov (United States)

    ... about 4 to 7 days. Outlook (Prognosis) The success rate for hydrocele repair is very high. The ... ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow ...

  1. Craniosynostosis repair

    Science.gov (United States)

    ... children having an open repair may need a transfusion) Reaction to medicines Risks for this surgery are: Infection in the brain Bones connect together again, and more surgery is needed Brain swelling Damage to brain tissue

  2. Optimize steam cracking with online NIR analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, D.; Descales, B.; Bages, S.; Bellet, S.; Llinas, J.R. [BP Chemicals S.N.C., Lavera (France); Loublier, M.; Maury, J.P. [Naphtachimie, Lavera (France); Martens, A. [AMS Conseil, Martigues (France)

    1995-12-01

    At Lavera, the steam cracker of Naphtachimie (a 50/50 subsidiary of BP Chemicals and Elf Atochem) was the first equipped with online NIR analysis of naphtha feedstock. The 24 furnaces of the plant produce more than 670,000 tpy of ethylene. Since 1991, these furnaces have been controlled by an in-house, online process control model that uses the 13 naphtha properties provided by the online NIR analyzer to adjust the furnaces` operating conditions in real time. The naphtha represents between 70% and 95% of the unit feedstock. With the high level of NIR spectroscopy repeatability and the robustness of in-house models based on more than 15 years of experience, optimization of steam cracker operations allows a substantial induced benefit in the range of $1 million/yr. Other NIR online applications have been installed at BP Lavera on major industrial units such as motor gasoline blending optimization and crude oil distillation monitoring. The paper describes the principle of operation, online NIR analysis, and advantages and benefits.

  3. Ptosis repair.

    Science.gov (United States)

    Ng, John; Hauck, Matthew J

    2013-02-01

    Acquired blepharoptosis presents as both a functional and cosmetic problem commonly encountered by facial plastic surgeons. Ptosis repair can be both challenging and frustrating, especially given ever-increasing demands for an optimal cosmetic surgical result. The authors present a brief overview of key points to consider when attempting to achieve excellent blepharoptosis repair outcomes. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Upconverting and NIR emitting rare earth based nanostructures for NIR-bioimaging.

    Science.gov (United States)

    Hemmer, Eva; Venkatachalam, Nallusamy; Hyodo, Hiroshi; Hattori, Akito; Ebina, Yoshie; Kishimoto, Hidehiro; Soga, Kohei

    2013-12-07

    In recent years, significant progress was achieved in the field of nanomedicine and bioimaging, but the development of new biomarkers for reliable detection of diseases at an early stage, molecular imaging, targeting and therapy remains crucial. The disadvantages of commonly used organic dyes include photobleaching, autofluorescence, phototoxicity and scattering when UV (ultraviolet) or visible light is used for excitation. The limited penetration depth of the excitation light and the visible emission into and from the biological tissue is a further drawback with regard to in vivo bioimaging. Lanthanide containing inorganic nanostructures emitting in the near-infrared (NIR) range under NIR excitation may overcome those problems. Due to the outstanding optical and magnetic properties of lanthanide ions (Ln(3+)), nanoscopic host materials doped with Ln(3+), e.g. Y2O3:Er(3+),Yb(3+), are promising candidates for NIR-NIR bioimaging. Ln(3+)-doped gadolinium-based inorganic nanostructures, such as Gd2O3:Er(3+),Yb(3+), have a high potential as opto-magnetic markers allowing the combination of time-resolved optical imaging and magnetic resonance imaging (MRI) of high spatial resolution. Recent progress in our research on over-1000 nm NIR fluorescent nanoprobes for in vivo NIR-NIR bioimaging will be discussed in this review.

  5. NIR optimerer produktionen af gammeldags modnede sild

    DEFF Research Database (Denmark)

    Svensson, Vibeke Tølbøl; Bro, Rasmus; Nielsen, Henrik Hauch

    2005-01-01

    Måling med nærinfrarødt (NIR) lys er et godt supplement til de nuværende metoder til at følge modningen af sild saltede i tønder. Det viser resultaterne af et forskningsprojekt udført i samarbejde mellem Lykkeberg A/S, Danmarks Fiskeriundersøgelser og Den Kgl Veterinær- og Landbohøjskole. Ved hjælp...... af avanceret matematik er det nemt og hurtigt at bestemme modningsgraden af sild direkte fra en NIR måling....

  6. Using Massive Multivariate NIRS Data in Ryegrass

    DEFF Research Database (Denmark)

    Edriss, Vahid; Greve-Pedersen, Morten; Jensen, Christian S

    variance and the heritability for each bin were estimated using a mixed model. To use all the information for prediction, since we have 366 bins, a reduction in number of parameters is necessary. The usual method is to combine principal component analysis (PCA) and partial least square (PLS). Another...... (e.g. dry matter, protein content, etc.) for the next generation. In total 1984 NIRS data from 995 ryegrass families (first cut) were used. The Absorption of radiation in the region of 960 – 1690 nm in every 2 nm distance produced 366 bins to represent the NIRS spectrum. The amount of genetic...

  7. Cyclic steps incised on experimental bedrock

    Science.gov (United States)

    Yokokawa, M.; Kyogoku, A.; Kotera, A.; Izumi, N.

    2013-12-01

    the step shape has been predicted by the mathematical model (Izumi et al., 2012). Among three cases of sediment supply: 1 g/sec, 3 g/sec, and 6 g/sec with fixed water discharge (52 g/sec), the erosion rate was maximized in the cases of the sediment supply of 3 g/sec both in the cement-sand-water ratios of 2:150:50 and 3:150:50. The erosion rate is higher in the case of the moderate amount of sediment supply rather than in the case of the largest amount of sediment supply in which the alluvial cover effect inhibited erosion. This result is consistent with that observed in previous studies (Sklar & Dietrich, 2004; Johnson & Whipple, 2010). References Izumi, N., Yokokawa, M. & Parker G. 2012. Cyclic step morphology formed on bedrock. Annual Journal of Hydraulic Engineering 68(4) : I_955-I_960. Johnson, J.P.L. & Whipple, K.X. 2010. Evaluating the controls of shear stress, sediment supply, alluvial cover, and channel morphology on experimental bedrock incision rate. Journal of Geophysical Research 115, F02018, doi:10.1029/2009JF001335. Sklar, L.S. & Dietrich, W.E. 2004. A mechanistic model for river incision into bedrock by sultating bedload. Water Resources Re-search 40, W06301, doi:10.1029/2003WR002496.

  8. A skin abscess model for teaching incision and drainage procedures.

    Science.gov (United States)

    Fitch, Michael T; Manthey, David E; McGinnis, Henderson D; Nicks, Bret A; Pariyadath, Manoj

    2008-07-03

    Skin and soft tissue infections are increasingly prevalent clinical problems, and it is important for health care practitioners to be well trained in how to treat skin abscesses. A realistic model of abscess incision and drainage will allow trainees to learn and practice this basic physician procedure. We developed a realistic model of skin abscess formation to demonstrate the technique of incision and drainage for educational purposes. The creation of this model is described in detail in this report. This model has been successfully used to develop and disseminate a multimedia video production for teaching this medical procedure. Clinical faculty and resident physicians find this model to be a realistic method for demonstrating abscess incision and drainage. This manuscript provides a detailed description of our model of abscess incision and drainage for medical education. Clinical educators can incorporate this model into skills labs or demonstrations for teaching this basic procedure.

  9. Morphodynamic Model of Submarine Canyon Incision by Sandblasting

    Science.gov (United States)

    Zhang, L.; Parker, G.; Izumi, N.; Cartigny, M.; Li, T.; Wang, G.

    2017-12-01

    Submarine canyons are carved by turbidity currents under the deep sea. As opposed to subaerial canyons, the relevant processes are not easy to observe directly. Turbidity currents are bottom-hugging sediment gravity flows of that can incise or deposit on the seafloor to create submarine canyons or fans. The triggers of turbidity currents can be storms, edge waves, internal waves, canyon wall sapping, delta failure, breaching and hyperpycnal flows. The formation and evolution mechanisms of submarine canyons are similar to those of subaerial canyons, but have substantial differences. For example, sandblasting, rather than wear due to colliding gravel clasts is more likely to be the mechanism of bedrock incision. Submarine canyons incise downward, and often develop meander bends and levees within the canyon, so defining "fairways". Here we propose a simple model for canyon incision. The starting point of our model is the Macro Roughness Saltation Abrasion Alluviation model of Zhang et al. [2015], designed for bedrock incision by gravel clasts in mixed bedrock-alluvial rivers. We adapt this formulation to consider sandblasting as a means of wear. We use a layer-averaged model for turbidity current dynamics. The current contains a mixture of mud, which helps drive the flow but which does not cause incision, and sand, which is the agent of incision. We show that the model can successfully model channel downcutting, and indeed illustrate the early formation of net incisional cyclic steps, i.e. upstream-migrating undulations on the bed associated with transcritical (in the Froude sense) flow. These steps can be expected to abet the process of incision.

  10. Vertical compared with transverse incisions in abdominal surgery

    DEFF Research Database (Denmark)

    Grantcharov, T P; Rosenberg, J

    2001-01-01

    . SETTING: Teaching hospital, Denmark. SUBJECTS: Patients undergoing open abdominal operations. INTERVENTIONS: For some of the variables (burst abdomen and incisional hernia) it was considered adequate to include retrospective studies. Studies were identified through Medline, Cochrane library, Embase...... with fewer complications (pain, burst abdomen, and pulmonary morbidity) and there is lower incidence of late incisional hernia after transverse compared with vertical laparotomy. A midline incision is still the incision of choice in conditions that require rapid intra-abdominal entry (such as trauma...

  11. Diathermy versus scalpel incisions for open cholecystectomy comparative study

    International Nuclear Information System (INIS)

    Ali, M.A.; Niazi, W.A.K.

    2014-01-01

    The aim of the study was to make a comparison between skin incisions made with electrocautery versus scalpel in terms of their safety, efficacy and post-operative complications. Design: A randomized controlled study. Setting: The study was conducted in Combined Military Hospital (CMH) Kharian, Pakistan airforce (PAF) Hospital Sargodha. Duration of Study: May 2008 to August 2011. Patients and Methods: Ninety seven patients who underwent open cholecystectomy were randomly divided into two groups on the basis of the use of electrocautery versus steel scalpel for making skin incision and sub-cutaneous tissue dissection. Parameters recorded were, time taken from skin incision to full incising of the peritoneum, length of the wound, amount of blood loss during this step of surgery in each group. Post-operative pain scoring using visual analogue scale was done. Wound complications such as infection, haematoma/seroma and dehiscence were noted too. One month of follow up was recorded in each group. Subsequently a comparison of these findings was done. Results: Incision time (sec/cm/sub 2/) was longer in scalpel group than in diathermy group (p = 0.001), whereas, incision blood loss (ml/cm/sub 2/) was significantly less in diathermy group than in scalpel group (p = 0.03). There was no difference in post-operative pain perception as delineated by visual pain analogue scoring system between the two groups (p = 0.57). Post-operative wound complications and the final healing of wound at 01 month of follow-up were almost similar in both groups. Conclusion: Electrocautery may be used safely without any untoward complication in making skin incision and sub-cutaneous tissue dissection with an advantage of reduced incision time and and less blood loss. (author)

  12. Rectus abdominis atrophy after ventral abdominal incisions: midline versus chevron.

    Science.gov (United States)

    Vigneswaran, Y; Poli, E; Talamonti, M S; Haggerty, S P; Linn, J G; Ujiki, M B

    2017-08-01

    Although many outcomes have been compared between a midline and chevron incision, this is the first study to examine rectus abdominis atrophy after these two types of incisions. Patients undergoing open pancreaticobiliary surgery between 2007 and 2011 at our single institution were included in this study. Rectus abdominis muscle thickness was measured on both preoperative and follow-up computed tomography (CT) scans to calculate percent atrophy of the muscle after surgery. At average follow-up of 24.5 and 19.0 months, respectively, rectus abdominis atrophy was 18.9% greater in the chevron (n = 30) than in the midline (n = 180) group (21.8 vs. 2.9%, p 20% atrophy at follow-up compared with 10% with a midline incision [odds ratio (OR) 9.0, p atrophy of the rectus abdominis compared with midline incisions. The long-term effects of transecting the rectus abdominis and disrupting its innervation creates challenging abdominal wall pathology. Atrophy of the abdominal wall can not be readily fixed with an operation, and this significant side effect of a transverse incision should be factored into the surgeon's decision-making process when choosing a transverse over a midline incision.

  13. Benzene-derived N2-(4-hydroxyphenyl)-deoxyguanosine adduct: UvrABC incision and its conformation in DNA

    Energy Technology Data Exchange (ETDEWEB)

    Hang, Bo; Rodriguez, Ben; Yang, Yanu; Guliaev, Anton B.; Chenna, Ahmed

    2010-06-14

    Benzene, a ubiquitous human carcinogen, forms DNA adducts through its metabolites such as p-benzoquinone (p-BQ) and hydroquinone (HQ). N(2)-(4-Hydroxyphenyl)-2'-deoxyguanosine (N(2)-4-HOPh-dG) is the principal adduct identified in vivo by (32)P-postlabeling in cells or animals treated with p-BQ or HQ. To study its effect on repair specificity and replication fidelity, we recently synthesized defined oligonucleotides containing a site-specific adduct using phosphoramidite chemistry. We here report the repair of this adduct by Escherichia coli UvrABC complex, which performs the initial damage recognition and incision steps in the nucleotide excision repair (NER) pathway. We first showed that the p-BQ-treated plasmid was efficiently cleaved by the complex, indicating the formation of DNA lesions that are substrates for NER. Using a 40-mer substrate, we found that UvrABC incises the DNA strand containing N(2)-4-HOPh-dG in a dose- and time-dependent manner. The specificity of such repair was also compared with that of DNA glycosylases and damage-specific endonucleases of E. coli, both of which were found to have no detectable activity toward N(2)-4-HOPh-dG. To understand why this adduct is specifically recognized and processed by UvrABC, molecular modeling studies were performed. Analysis of molecular dynamics trajectories showed that stable G:C-like hydrogen bonding patterns of all three Watson-Crick hydrogen bonds are present within the N(2)-4-HOPh-G:C base pair, with the hydroxyphenyl ring at an almost planar position. In addition, N(2)-4-HOPh-dG has a tendency to form more stable stacking interactions than a normal G in B-type DNA. These conformational properties may be critical in differential recognition of this adduct by specific repair enzymes.

  14. Treatment of bilateral mammary ptosis and pectus excavatum through the same incision in one surgical stage

    Directory of Open Access Journals (Sweden)

    Fernando Passos Rocha

    Full Text Available CONTEXT: Congenital deformities of the anterior thoracic wall are characterized by unusual development of the costal cartilages. All these medical conditions are frequently associated with a variety of breast deformities. Several surgical techniques have been described for correcting them, going from sternochondroplasty to, nowadays, minimally invasive techniques and silicone prosthesis implantation. CASE REPORT: The present article reports the case of a young female patient who presented bilateral mammary ptosis and moderate pectus excavatum that caused a protrusion between the eighth and the tenth ribs and consequent esthetic disharmony. The proposed surgical treatment included not only subglandular breast implants of polyurethane, but also resection of part of the rib cartilage and a bone segment from the eighth, ninth and tenth ribs by means of a single submammary incision in order to make the scar minimally visible. Correction through a single incision benefited the patient and provided an excellent esthetic result. CONCLUSIONS: The techniques used to repair bilateral mammary ptosis and pectus excavatum by plastic and thoracic surgery teams, respectively, have been shown to be efficient for correcting both deformities. An excellent esthetic and functional result was obtained, with consequent reestablishment of the patient's self-esteem.

  15. Technique and results after distal braquial biceps tendon reparation, through two anterior mini-incisions

    Science.gov (United States)

    Pascarelli, Luciano; Righi, Lúcio César Silva; Bongiovanni, Roberto Rangel; Imoto, Rogério Sano; Teodoro, Renato Loureiro; Ferro, Hemanoel Fernando dos Anjos

    2013-01-01

    OBJECTIVE: Evaluation of postoperative results of repair of distal biceps brachii ruptures through a two anterior mini-incisions. METHODS: Nine patients with clinical and imaging (MRI) diagnosis of total lesion of the biceps brachii at its insertion were operated with a surgical technique with two mini-incisions between 2008 and 2011. The patients were evaluated after three months of evolution and all of them recovered the fully flexion-extension arch. RESULTS: Two patients (22.2%) presented a limitation of 20 degrees of supination. One patient (11.1%) had radial nerve palsy, but was totally recovered after five months. In one patient (11.1%) the muscle remained retracted, but the insertion was recovered. In three patients (33.3%) adhesion was observed on the proximal scar. There was no clinical or radiographic evidence of radioulnar synostosis after six months of evolution. All patients reported satisfaction with the treatment. CONCLUSIONS: We conclude that the presented method shows good results as well as other techniques, with less risk of adhesion on the flexor fold of the elbow. Level of Evidence IV, Case Series. PMID:24453647

  16. Distal biceps tendon rupture reconstruction using muscle-splitting double-incision approach.

    Science.gov (United States)

    Tarallo, Luigi; Mugnai, Raffaele; Zambianchi, Francesco; Adani, Roberto; Catani, Fabio

    2014-08-16

    To evaluate the clinical and functional results after repair of distal biceps tendon tears, following the Morrey's modified double-incision approach. We retrospectively reviewed 47 patients with distal rupture of biceps brachii treated between 2003 and 2012 in our Orthopedic Department with muscle-splitting double-incision technique. Outcome measures included the Mayo elbow performance, the DASH questionnaire, patient's satisfaction, elbow and forearm motion, grip strength and complications occurrence. At an average 18 mo follow-up (range, 7 mo-10 years) the average Mayo elbow performance and DASH score were respectively 97.2 and 4.8. The elbow flexion range was 94%, extension was -2°, supination was 93% and pronation 96% compared with the uninjured limb. The mean grip strength, expressed as percentage of respective contralateral limb, was 83%. The average patient satisfaction rating on a Likert scale (from 0 to 10) was 9.4. The following complications were observed: 3 cases of heterotopic ossification (6.4%), one (2.1%) re-rupture of the tendon at the site of reattachment and 2 cases (4.3%) of posterior interosseous nerve palsy. No complication required further surgical treatment. This technique allows an anatomic reattachment of distal biceps tendon at the radial tuberosity providing full functional recovery with low complication rate.

  17. Outcome of pediatric hypospadias repair in adulthood

    Directory of Open Access Journals (Sweden)

    Boris Chertin

    2010-04-01

    Full Text Available Boris Chertin1, Dan Prat1, Ofer Z Shenfeld21Division of Pediatric Urology, 2Department of Urology, Shaare Zedek Medical Center, Jerusalem, Faculty of Medical Science, Hebrew University, Jerusalem, IsraelPurpose: To review the evolution of the technique of hypospadias repair.Methods: A search of Pubmed, Medline and the Journal of Pediatric Urology was performed, and papers dealing with surgical techniques for hypospadias repair were critally reviewed. Special emphasis was given to papers on the effects in the long term of hypospadias repair on voiding and sexual dysfunction.Results: The techniques for hypospadias repair have evolved over the years. The most popular technique now is tubularized incised plate urethroplasty. Long-term results with the use of the new techniques of the hypospadias repair in terms of voiding and sexual problems should be addressed.Conclusion: There is a need for valid studies on the outcomes of hypospadias repair in adults that were performed in childhood in terms of cosmetic appearance, voiding and sexual performance.Keywords: hypospadias, hypospadias surgery, adult, later outcome

  18. Experimental radiation carcinogenesis is studies at NIRS

    International Nuclear Information System (INIS)

    Sado, Toshihiko

    1992-01-01

    Experimental radiation carcinogenesis studies conducted during the past decade at NIRS are briefly reviewed. They include the following: 1) Age dependency of susceptibility to radiation carcinogenesis. 2) Radiation-induced myeloid leukemia. 3) Mechanism of fractionated X-irradiation (FX) induced thymic lymphomas. 4) Significance of radiation-induced immunosuppression in radiation carcinogenesis in vivo. 5) Other ongoing studies. (author)

  19. Monitoring of whey quality with NIR spectroscopy

    DEFF Research Database (Denmark)

    Kucheryavskiy, Sergey; Lomborg, Carina

    2015-01-01

    The possibility of using near-infrared (NIR) spectroscopy for monitoring of liquid whey quality parameters during protein production process has been tested. The parameters included total solids, lactose, protein and fat content. The samples for the experiment were taken from real industrial...

  20. Agricultural applications of NIR reflectance and transmittance

    DEFF Research Database (Denmark)

    Gislum, René

    2009-01-01

    There has been a considerable increase in the use of near infrared (NIR) reflectance and transmittance spectroscopy technologies for rapid determination of quality parameters in agriculture, including applications within crop product quality, feed and food quality, manure quality, soil analyses etc...

  1. Chromatin factors affecting DNA repair in mammalian cell nuclei

    International Nuclear Information System (INIS)

    Harless, J.; Hittelman, W.; Meyn, R.; Hewitt, R.

    1983-01-01

    We are investigating chromatin factors that participate in the incision step of DNA repair in eukaryotic cells. Localization of repair activity within nuclei, the stability and extractability of activity, the specificity for recognizing damage in chromatin or purified DNA as substrates are of interest in this investigation of human cells, CHO cells, and their radiation sensitive mutants. We have developed procedures that provide nuclei in which their DNA behaves as a collection of circular molecules. The integrity of the DNA in human nuclei can be maintained during incubation in appropriate buffers for as long as 60 minutes. When cells or nuclei are exposed to uv light prior to incubation, incisions presumably associated with DNA repair can be demonstrated. Incision activity is stable to prior extraction of nuclei with 0.6 M NaCl, which removes many nonhistone proteins. Our studies are consistent with an hypothesis that factors responsible for initiating DNA repair are localized in the nuclear matrix. 18 references, 3 figures

  2. Repair process and a repaired component

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, III, Herbert Chidsey; Simpson, Stanley F.

    2018-02-20

    Matrix composite component repair processes are disclosed. The matrix composite repair process includes applying a repair material to a matrix composite component, securing the repair material to the matrix composite component with an external securing mechanism and curing the repair material to bond the repair material to the matrix composite component during the securing by the external securing mechanism. The matrix composite component is selected from the group consisting of a ceramic matrix composite, a polymer matrix composite, and a metal matrix composite. In another embodiment, the repair process includes applying a partially-cured repair material to a matrix composite component, and curing the repair material to bond the repair material to the matrix composite component, an external securing mechanism securing the repair material throughout a curing period, In another embodiment, the external securing mechanism is consumed or decomposed during the repair process.

  3. Motorcycle Repair.

    Science.gov (United States)

    Hein, Jim; Bundy, Mike

    This motorcycle repair curriculum guide contains the following ten areas of study: brake systems, clutches, constant mesh transmissions, final drives, suspension, mechanical starting mechanisms, electrical systems, fuel systems, lubrication systems, and overhead camshafts. Each area consists of one or more units of instruction. Each instructional…

  4. Repair of distal biceps brachii tendon ruptures.

    Science.gov (United States)

    Bell, R H; Wiley, W B; Noble, J S; Kuczynski, D J

    2000-01-01

    This study consisted of 26 male patients with distal biceps tendon ruptures, 2 of whom had bilateral injuries, making the total number of ruptures 28. The average age at injury was 45 years. The treatment groups were the following: 3 were treated without surgery, 4 were repaired with brachialis tenodesis, and 21 were reattached to the radial tuberosity by the 2-incision Boyd-Anderson approach. Patients underwent follow-up a minimum of 14 months after surgery, with the average being 43 months. Outcome was evaluated based on the physical examination, isokinetic testing of strength and endurance of flexion and supination, and radiographic analysis.

  5. Effects of two different incision phacoemulsification on corneal astigmatism

    Directory of Open Access Journals (Sweden)

    Lu Huo

    2014-12-01

    Full Text Available AIM:To compare the effect of different incision in corneal astigmatism after phacoemulsification. METHODS: Totally 88 cases(122 eyeswith pure cataract were randomly divided into two groups. Forty cases(60 eyeswere clarity corneal incision in group A, and 48 cases(62 eyeswere sclera tunnel incision in group B. Mean corneal astigmatism, surgically induced astigmatism(SIA, uncorrected visual acuity(UCVAand best correct vision acuity(BCVAwere observed in pre- and post-operation at 1d; 1wk; 1mo.RESULTS: The mean astigmatism had statistically significant difference between two groups at 1d; 1wk; 1mo after operation(PPP>0.05. UCVA≥0.5 and BCVA≥0.8 had statistically significant difference at 1d; 1wk(PP>0.05.CONCLUSION: Phacoemulsification with scleral tunnel incision remove combined intraocular lens(IOLimplantation has small changes to corneal astigmatism. By selecting personalized corneal incision according to the corneal topography might be more beneficial.

  6. Small incision removal of nylon foil orbital implants.

    Science.gov (United States)

    Liu, Catherine Y; Vemuri, Swapna; Tao, Jeremiah P

    2015-01-01

    To describe a small incision technique for the removal of a nylon foil orbital wall implant. The authors retrospectively reviewed the charts of 9 patients who underwent a minimally invasive anterior orbitotomy for nylon foil explantation. Indications for removal and surgical technique, including size of orbitotomy incision and extent of orbital dissection, were recorded. Motility, globe position, strabismus pre- and post procedure, and complications were also assessed. Photographs, videos, and postoperative imaging were included, when available. The indications for removal were adjacent sinusitis (4 cases), undesirable implant position (3), orbital abscess (1), and adjacent orbital emphysema (1). The removal technique was associated with no changes in motility, globe position, or strabismus postprocedure. The average incision size was 1.1 cm, and the procedure was rapid, usually seconds once the anterior aspect of the implant was exposed and grasped with a hemostat. The dissection in all cases was to the anterior aspect of the implant without a need for deep orbital manipulation. The authors demonstrate through video that the implant folds to exit through a small incision. No adverse events were noted. Nasal endoscopy and radiography demonstrated a fibrous capsule that maintained orbital structure and support. Thin nylon foil implant can be explanted safely and efficiently through a very small incision. The orbit maintains structure and configuration postexplantation in this series.

  7. External defibrillation failure due to antimicrobial incise drape.

    Science.gov (United States)

    Barbara, David W; Dietz, Niki M; White, Roger D; Pochettino, Alberto; Nuttall, Gregory A

    2013-09-01

    Antimicrobial incise drapes adhere to a patient's skin during surgery in an attempt to reduce surgical infections. We describe a patient undergoing repeated aortic valve replacement who experienced sudden ventricular fibrillation before median sternotomy. External defibrillation was unsuccessful on multiple attempts using several defibrillators. On removal of the incise drape from the patient's chest, external defibrillation was immediately successful. Increased transthoracic impedance can be caused by multiple factors and may prevent defibrillation. To our knowledge, this is the first reported case of an antimicrobial incise drape preventing defibrillation. If external defibrillation, cardioversion, or pacing is indicated intraoperatively, we recommend prompt removal of the antimicrobial incise drapes before electrode placement if the drapes overlay the intended pad position. Since this case, our institutional practice has now changed to placement of 2 external adhesive defibrillator electrodes onto the patient's skin lateral to the surgical field before incise drape application to allow for defibrillation. Copyright © 2013 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  8. Open, intraperitoneal, ventral hernia repair: lessons learned from laparoscopy.

    Science.gov (United States)

    Ponsky, Todd A; Nam, Arthur; Orkin, Bruce A; Lin, Paul P

    2006-03-01

    Recent literature suggests that laparoscopic repair of ventral hernias may have very low recurrence rates. However, laparoscopy may not be feasible in certain situations. We describe an open technique that uses the tension-free retrofascial principles of laparoscopic repair without the need for subcutaneous flaps. Through an incision in the hernia, the peritoneum is entered and adhesions are taken down. A piece of DualMesh (W.L. Gore & Associates, Inc, Newark, Del) is trimmed to fit with a 5-cm circumferential overlap. A vertical incision is made in the mid portion of the mesh. The mesh is fixed in an intraperitoneal retrofascial position using GORE-TEX sutures (W.L. Gore & Associates, Inc). The sutures are brought through the abdominal wall using a laparoscopic suture passer and tied into place on one side of the mesh. That side is then tacked to the posterior fascia with a spiral tacking device. The other side is sutured into place in a similar fashion and then tacked to the fascia by passing the spiral tacking device through the incision in the mesh. The mesh incision is closed with a running GORE-TEX suture. The overlying tissues are closed in layers.

  9. NIR spectroscopic properties of aqueous acids solutions.

    Science.gov (United States)

    Omar, Ahmad Fairuz; Atan, Hanafi; Matjafri, Mohd Zubir

    2012-06-15

    Acid content is one of the important quality attributes in determining the maturity index of agricultural product, particularly fruits. Despite the fact that much research on the measurement of acidity in fruits through non-destructive spectroscopy analysis at NIR wavelengths between 700 to 1,000 nm has been conducted, the same response towards individual acids is not well known. This paper presents NIR spectroscopy analysis on aqueous citric, tartaric, malic and oxalic solutions through quantitative analysis by selecting a set of wavelengths that can best be used to measure the pH of the solutions. The aquaphotomics study of the acid solutions has generated R² above 0.9 for the measurement of all acids. The most important wavelengths for pH are located at 918-925 nm and 990-996 nm, while at 975 nm for water.

  10. Optical NIR monitoring of skeletal muscle contraction

    Science.gov (United States)

    Lago, Paolo; Gelmetti, Andrea; Pavesi, Roberta; Zambarbieri, Daniela

    1996-12-01

    NIR spectroscopy allows monitoring of muscle oxygenation and perfusion during contraction. The knowledge of modifications of blood characteristics in body tissues has relevant clinical interest. A compact and reliable device, which makes use of two laser diodes at 750 and 810 nm coupled with the skin surface through optical fibers, was tested. NIR and surface EMG signals during isometric contractions both in normal and ischaemic conditions were analyzed. A set of parameters from the 750/810 spectroscopic curve was analyzed. Two different categories depending on the recovery rate from maximal voluntary contraction to basal oxygenation conditions were found. This behavior can give information about metabolic modifications during muscle fatigue. Interesting results in testing isokinetic rehabilitation training were also obtained.

  11. A possible mechanism for exonuclease 1-independent eukaryotic mismatch repair

    Science.gov (United States)

    Kadyrov, Farid A.; Genschel, Jochen; Fang, Yanan; Penland, Elisabeth; Edelmann, Winfried; Modrich, Paul

    2009-01-01

    Mismatch repair contributes to genetic stability, and inactivation of the mammalian pathway leads to tumor development. Mismatch correction occurs by an excision-repair mechanism and has been shown to depend on the 5′ to 3′ hydrolytic activity exonuclease 1 (Exo1) in eukaryotic cells. However, genetic and biochemical studies have indicated that one or more Exo1-independent modes of mismatch repair also exist. We have analyzed repair of nicked circular heteroduplex DNA in extracts of Exo1-deficient mouse embryo fibroblast cells. Exo1-independent repair under these conditions is MutLα-dependent and requires functional integrity of the MutLα endonuclease metal-binding motif. In contrast to the Exo1-dependent reaction, we have been unable to detect a gapped excision intermediate in Exo1-deficient extracts when repair DNA synthesis is blocked. A possible explanation for this finding has been provided by analysis of a purified system comprised of MutSα, MutLα, replication factor C, proliferating cell nuclear antigen, replication protein A, and DNA polymerase δ that supports Exo1-independent repair in vitro. Repair in this system depends on MutLα incision of the nicked heteroduplex strand and dNTP-dependent synthesis-driven displacement of a DNA segment spanning the mismatch. Such a mechanism may account, at least in part, for the Exo1-independent repair that occurs in eukaryotic cells, and hence the modest cancer predisposition of Exo1-deficient mammalian cells. PMID:19420220

  12. Sharp compared with blunt fascial incision at cesarean delivery

    DEFF Research Database (Denmark)

    Aabakke, Anna J M; Hare, Kristine J; Krebs, Lone

    2014-01-01

    OBJECTIVE: To compare patient preference for either sharp incision with scissors or blunt manual cleavage of the fascia at cesarean delivery in a randomized controlled trial in which each woman was her own control. STUDY DESIGN: Women undergoing primary cesarean delivery (n=34) were randomized...... to side distribution of sharp or blunt incision of the fascia (sharp right and blunt left or blunt right and sharp left) and followed three months postoperatively. The primary outcome was patient preference for the right or left side of the scar 3 months postoperatively and modeled by polytomous logistic...... difference was found in patient preference with regard to sharp or blunt incision of the fascia, nor was there a significant difference in postoperative pain scores. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov: www.clinicaltrials.org;NCT01297725....

  13. The problem of insufficient incisal display: a case presentation.

    Science.gov (United States)

    Castillo, Rodrigo

    2010-01-01

    Enhancement of facial beauty is one of the primary elective goals of patients seeking dental care. Frequently, improvements in natural beauty can be expected to follow restoration of ideal relationships between the denture and the facial soft tissues. A very important feature in a youthful appearance is the incisal tooth display; the amount of maxillary incisal exposure gradually decreases with age, accompanied by a gradual increase in mandibular incisal exposure. However, this problem could be present in young people where the effects of age should not be apparent yet. There are some other factors that could accelerate this process. The present case illustrates the improvement and rejuvenation of an unesthetic young smile through restorative treatment.

  14. Giant Nasolabial Cyst Treated Using Neumann Incision: Case Report

    Directory of Open Access Journals (Sweden)

    Ordones, Alexandre Beraldo

    2013-09-01

    Full Text Available Introduction: A nasolabial cyst is an ectodermal development cyst. It presents as a fullness of canine fossa, nasal ala, or vestibule of the nose. It is rare and usually small. Treatment consists of complete surgical excision or transnasal endoscopic marsupialization. Objective: To describe a giant nasolabial cyst case treated using Neumann incision. Case Report: A 37-year-old man was referred to the otolaryngology department with nasal obstruction and nasal deformity. Computed tomography showed a nasal cystic lesion 4 × 4.5 × 5 cm wide. Surgical excision using Neumann incision was performed. Discussion: Neumann incision provides wide access to the nasal cavity and may be useful in nasolabial cyst treatment.

  15. Force modeling for incision surgery into tissue with haptic application

    Science.gov (United States)

    Kim, Pyunghwa; Kim, Soomin; Choi, Seung-Hyun; Oh, Jong-Seok; Choi, Seung-Bok

    2015-04-01

    This paper presents a novel force modeling for an incision surgery into tissue and its haptic application for a surgeon. During the robot-assisted incision surgery, it is highly urgent to develop the haptic system for realizing sense of touch in the surgical area because surgeons cannot sense sensations. To achieve this goal, the force modeling related to reaction force of biological tissue is proposed in the perspective on energy. The force model describes reaction force focused on the elastic feature of tissue during the incision surgery. Furthermore, the force is realized using calculated information from the model by haptic device using magnetorheological fluid (MRF). The performance of realized force that is controlled by PID controller with open loop control is evaluated.

  16. Design and construction of a NIR spectrometer

    CERN Document Server

    Barcala-Riveira, J M; Fernandez-Marron, J L; Molero-Menendez, F; Navarrete-Marin, J J; Oller-Gonzalez, J C

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs.

  17. Design and construction of a NIR spectrometer

    International Nuclear Information System (INIS)

    Barcala Riveira, J. M.; Fernandez Marron, J. L.; Alberdi Primicia, J.; Molero Menendez, F.; Navarrete Marin, J. J.; Oller Gonzalez, J. C.

    2003-01-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs

  18. Complications of Supine Surgical Achilles Tendon Repair.

    Science.gov (United States)

    Marcel, John J; Sage, Katherine; Guyton, Gregory P

    2018-02-01

    Open Achilles tendon surgery with the patient in the supine position potentially avoids the complications of the prone position, but the safety and viability of the supine position for this procedure are not known. The aim of this study was to test the hypothesis that supine positioning for open repair of acute Achilles tendon ruptures would be safe, with low wound and neurologic complication rates. Supine position safety in acute Achilles tendon repair was investigated. Consecutive cases of supine Achilles tendon surgical repair performed by one surgeon from 2010 to 2015 were retrospectively reviewed. Patients were included if they were surgically treated with primary repair in the supine position within 15 days of injury and did not undergo concomitant surgery. A paramedian incision 1 cm medial to the Achilles sheath was used. Initial chart review identified 161 patients who underwent any type of Achilles tendon surgery in the supine position, of whom 45 patients met the inclusion criteria. This group included 39 men and 6 women with an average age of 41 years (range, 20-66 years). Median length of follow-up was 116 days (range, 25-1,589 days). Average body mass index was 29 kg/m 2 (range, 23-36 kg/m 2 ). There were no infections, sural nerve injuries, or reruptures. The supine position was safe for primary open Achilles tendon repair, with no wound or neurologic complications. Level IV, Case Series.

  19. Minimizing surgical skin incision scars with a latex surgical glove.

    Science.gov (United States)

    Han, So-Eun; Ryoo, Suk-Tae; Lim, So Young; Pyon, Jai-Kyung; Bang, Sa-Ik; Oh, Kap-Sung; Mun, Goo-Hyun

    2013-04-01

    The current trend in minimally invasive surgery is to make a small surgical incision. However, the excessive tensile stress applied by the retractors to the skin surrounding the incision often results in a long wound healing time and extensive scarring. To minimize these types of wound problems, the authors evaluated a simple and cost-effective method to minimize surgical incision scars based on the use of a latex surgical glove. The tunnel-shaped part of a powder-free latex surgical glove was applied to the incision and the dissection plane. It was fixed to the full layer of the dissection plane with sutures. The glove on the skin surface then was sealed with Ioban (3 M Health Care, St. Paul, MN, USA) to prevent movement. The operation proceeded as usual, with the retractor running through the tunnel of the latex glove. It was possible to complete the operation without any disturbance of the visual field by the surgical glove, and the glove was neither torn nor separated by the retractors. The retractors caused traction and friction during the operation, but the extent of damage to the postoperative skin incision margin was remarkably less than when the operation was performed without a glove. This simple and cost-effective method is based on the use of a latex surgical glove to protect the surgical skin incision site and improve the appearance of the postoperative scar. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  20. Single-incision sling operations for urinary incontinence in women.

    Science.gov (United States)

    Nambiar, Arjun; Cody, June D; Jeffery, Stephen T

    2014-06-01

    Urinary incontinence has been shown to affect up to 50% of women. Studies in the United States have shown that up to 80% of these women have an element of stress urinary incontinence. Colposuspension and now mid-urethral slings have been shown to be effective in treating patients with stress incontinence. However, associated adverse events include bladder and bowel injury, groin pain and haematoma formation. This has led to the development of third-generation single-incision slings, also referred to as mini-slings.It should be noted that TVT-Secur (Gynecare, Bridgewater, NJ, USA) is one type of single-incision sling; it has been withdrawn from the market because of poor results. However, it is one of the most widely studied single-incision slings and was used in several of the trials included in this review. Despite its withdrawal from clinical use, it was decided that data pertaining to this sling should be included in the first iteration of this review, so that level 1a data are available in the literature to confirm its lack of efficacy. To assess the effectiveness of mini-sling procedures in women with urodynamic clinical stress or mixed urinary incontinence in terms of improved continence status, quality of life or adverse events. We searched the Cochrane Incontinence Group Specialised Trials Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and MEDLINE in process; we handsearched journals and conference proceedings (searched 6 February 2013) and searched ClinicalTrials.gov (searched 20 September 2012), the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (searched 20 September 2012) and the reference lists of relevant articles. Randomised or quasi-randomised controlled trials in women with urodynamic stress incontinence, symptoms of stress incontinence or stress-predominant mixed urinary incontinence, in which at least one trial arm involves one of the

  1. Better outcome from arthroscopic partial meniscectomy than skin incisions only?

    DEFF Research Database (Denmark)

    Roos, Ewa M; Hare, Kristoffer Borbjerg; Nielsen, Sabrina Mai

    2018-01-01

    . In total, nine participants experienced 11 adverse events; six in the surgery group and three in the skin-incisions-only group. CONCLUSION: We found greater improvement from arthroscopic partial meniscectomy compared with skin incisions only at 2 years, with the statistical uncertainty of the between......-group difference including what could be considered clinically relevant. Because of the study being underpowered, nearly half in the sham group being non-blinded and one-third crossing over to surgery, the results cannot be generalised to the greater patient population. TRIAL REGISTRATION NUMBER: NCT01264991....

  2. Ultrasonic diagnosis and transurethral incision of ureterocele with hydronephrosis

    DEFF Research Database (Denmark)

    Waaddegaard, P; Miskowiak, J; Stage, P

    1991-01-01

    In a 65-year-old woman with right-sided loin pain, ultrasonography revealed a grossly dilated and obstructed right pyelogram due to a 50-mm ureterocele. After transurethral lateral incision of the ureterocele, there was complete recovery without vesicoureteric reflux. Ultrasonography is advantage......In a 65-year-old woman with right-sided loin pain, ultrasonography revealed a grossly dilated and obstructed right pyelogram due to a 50-mm ureterocele. After transurethral lateral incision of the ureterocele, there was complete recovery without vesicoureteric reflux. Ultrasonography...

  3. Meta-analysis of the effectiveness of surgical scalpel or diathermy in making abdominal skin incisions.

    LENUS (Irish Health Repository)

    Ahmad, Nasir Zaheer

    2012-02-01

    BACKGROUND: Surgical scalpels are traditionally used to make skin incisions. Diathermy incisions on contrary are less popular among the surgeons. The aim of this meta-analysis was to compare the effectiveness of both techniques and address the common fallacies about diathermy incisions. METHODS: A literature search of MEDLINE and Cochrane databases was done, using the keywords diathermy, cold scalpel, and incisions. Eleven clinical trials comparing both methods of making skin incisions were selected for meta-analysis. The end points compared included postoperative wound infection, pain in first 24 hours after surgery, time taken to complete the incisions, and incision-related blood loss. RESULTS: Postoperative wound infection rate was comparable in both techniques (P = 0.147, odds ratio = 1.257 and 95% CI = 0.923-1.711). Postoperative pain was significantly less with diathermy incisions in first 24 hours (P = 0.031, weighted mean difference = 0.852 and 95% CI = 0.076-1.628). Similarly, the time taken to complete the incision and incision-related blood loss was significantly less with diathermy incisions (95% CI = 0.245-0.502 and 0.548-1.020, respectively). CONCLUSION: Diathermy incisions are equally prone to get wound infection, as do the incisions made with scalpel. Furthermore, lower incidence of early postoperative pain, swiftness of the technique, and a reduced blood loss are the encouraging facts supporting routine use of diathermy for abdominal skin incisions after taking careful precautions.

  4. Pharmaceutical applications using NIR technology in the cloud

    Science.gov (United States)

    Grossmann, Luiz; Borges, Marco A.

    2017-05-01

    NIR technology has been available for a long time, certainly more than 50 years. Without any doubt, it has found many niche applications, especially in the pharmaceutical, food, agriculture and other industries due to its flexibility. There are a number of advantages over other existing analytical technologies we can list, for example virtually no need for sample preparation; usually NIR does not demand sample destruction and subsequent discard; NIR provides fast results; NIR does not require extensive operator training and carries small operating costs. However, the key point about NIR technology is the fact that it's more related to statistics than chemistry or, in other words, we are more concerned about analyzing and distinguishing features within the data than looking deep into the chemical entities themselves. A simple scan reading in the NIR range usually involves huge inflows of data points. Usually we decompose the signals into hundreds of predictor variables and use complex algorithms to predict classes or quantify specific content. NIR is all about math, especially by converting chemical information into numbers. Easier said than done. A NIR signal is a very complex one. Usually the signal responses are not specific to a particular material, rather, each grouṕs responses add up, thus providing low specificity of a spectral reading. This paper proposes a simple and efficient method to analyze and compare NIR spectra for the purpose of identifying the presence of active pharmaceutical ingredients in finished products using low cost NIR scanning devices connected to the internet cloud.

  5. Formulation and Evaluation of Exotic Fat Based Cosmeceuticals for Skin Repair

    OpenAIRE

    Mandawgade, S. D.; Patravale, Vandana B.

    2008-01-01

    Mango butter was explored as a functional, natural supplement and active skin ingredient in skin care formulations. A foot care cream was developed with mango butter to evaluate its medicinal value and protective function in skin repair. Qualitative comparison and clinical case studies of the product were carried out. Wound healing potential of foot care cream was investigated on the rat excision and incision wound models. Results of the clinical studies demonstrated complete repair of worn a...

  6. Herniotomy in resource-scarce environment: Comparison of incisions and techniques

    Directory of Open Access Journals (Sweden)

    Musa Ibrahim

    2015-01-01

    Full Text Available Background: There are various methods for surgical treatment of hernia and hydrocele in children with variable cost-effectiveness, recovery and cosmetic outcomes. This study analyses our experience with mini-incision/invasive herniotomy in children in resource-limited centre. Materials and Methods: Seven hundred and eighty-four n = 784 patients underwent herniotomy via conventional and mini-invasive methods were assigned into Group A and Group B. Three hundred and seventy-six n = 376 (47.95% in Group A while four hundred and eight n = 408 (52.04% in Group B. Eight hundred and seventeen (817 herniotomy was performed. Demographic data, hernia/hydrocele sides, volume of surgical suture used, surgery duration, and complications analysed. Results: Right side hernia and/or hydrocele were 464 (59.18%. 287 (36.60% had left sided while 33 (4.21% had bilateral hernia and/or hydrocele. There were 14 bilateral hernia repair in Group A and 19 in Group B. The lengths of operation time for unilateral repair ranged from 14 to 54 min in Group A (median, 23 min and 7-44 min in Group B (median, 15 min with a mean surgical duration of 15.48 ± 4.16 min in Group B versus 23.41 ± 5.94 min in Group A (P < 0.001 while the range of the lengths of operation time for bilateral repair in Group A was 20-54 min (median, 36 and 12-30 min (median, 21 in Group B with a mean duration of 36.35 ± 9.89 min in Group A versus 20.42 ± 4.83 min in Group B P = 0.00563. 376 sachets of 45 cm suture material were used in Group A versus 137 in Group B. There were total of 87 (23.13% complications in Group A versus 3 (1.47% in Group B P = 0.000513. Superficial wound infection and abscess were 9 (2.36% and 16 (4.25% in Group A versus none (0 in Group B. Conclusion: Mini-incision/invasive herniotomy in children and adolescents is fast, cost-effective with satisfactory cosmetic outcome and limited complications

  7. Urethrocutaneous fistulae after hypospadias repair: When do they occur?

    Science.gov (United States)

    Liao, Adelene Y; Smith, Grahame Hh

    2016-05-01

    The aim is to determine the incidence and timing of urethrocutaneous fistula diagnosis after hypospadias surgery. A retrospective review of all patients who had both initial hypospadias surgery and subsequent fistula repair from 1995 to 2012. A comparison was made between patients who had an initial onlay island flap procedure and those who had a tubularised incised plate repair. Patient age at initial surgery ranged from 6 months to 16 years of age. The median time to fistula presentation was 8.5 months with a range of less than 1 month to 13.9 years post-hypospadias surgery. The median time to fistula repair was 17 months. The overall fistula rate was 8%. There was no significant difference between the rates of fistulae for onlay island flap (9%) versus tubularised incised plate procedure (7%). Urethrocutaneous fistulae can present many years after the original hypospadias repair. The majority are diagnosed within the first year after surgery. Rates of fistulae are probably underreported due to short follow-up, but more importantly, due to patients transferring to other surgeons for fistula repair. © 2016 The Author Journal of Paediatrics and Child Health © 2016 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  8. The role of two-stage repair in modern hypospadiology

    Directory of Open Access Journals (Sweden)

    Aivar Bracka

    2008-01-01

    Full Text Available Hypospadias surgery continues to evolve. The enthusiasm for flap-based urethroplasty is waning and instead there is an increasing preference for urethroplasty that uses either the urethral plate alone or in combination with grafts. From the vast armamentarium of hypospadias repairs that are still in use, the author suggests a simple protocol of just three closely related procedures with which we can now repair almost all hypospadias. The tubularised incised plate (TIP repair and the ′Snodgraft′ modification of the TIP principle are simple and effective one-stage solutions when partial circumference urethroplasty is required. Conversely, the Bracka two-stage graft repair remains an ideal and versatile solution when a full circumference urethroplasty is required. It is particularly appropriate for severe primary hypospadias associated with a poor plate and marked chordee and also to replace a scarred, hairy or balanitis xerotica obliterans diseased urethra in re-operative salvage hypospadias.

  9. NIR-NIR fluorescence: A new genre of fingermark visualisation techniques.

    Science.gov (United States)

    King, Roberto S P; Hallett, Peter M; Foster, Doug

    2016-05-01

    A preliminary study reveals that finely divided cuprorivaite powder may be used to efficiently develop and subsequently image latent fingermarks across a range of highly patterned, coloured non-porous and semi-porous substrates using near infrared illumination and imaging. Problematic multi-coloured backgrounds provide very little interference under the illumination conditions used, and invoked fluorescence observed, when using this material. This is the first reported example of a NIR-NIR fluorophore for use within latent fingermark visualisation and offers the potential for application at the scene and in the laboratory. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Role of tubularization of urethral plate in development of urethrocutaneous fistula post hypospadias repair

    Directory of Open Access Journals (Sweden)

    Basim S Alsaywid

    2017-01-01

    Conclusion: Incision of the urethral plate did not affect the fistula rate. In comparison to international literature, the incidence of fistula was significantly higher which could be explained by the fact that one-third of those patients had a previous hypospadias repair.

  11. Superficial fascial system repair: an abdominoplasty technique to reduce local complications after caesarean delivery.

    Science.gov (United States)

    Al-Benna, Sammy; Al-Ajam, Yazan; Tzakas, Elias

    2009-05-01

    Abdominal incision complications are a major source of morbidity after caesarean delivery. Repair of the superficial fascial system may avert local complications after caesarean delivery by minimising tension to the skin and increasing the initial biomechanical strength of wound which has the potential to decrease early wound dehiscence and as a by-product correct suprapubic bulging.

  12. Versatility of tubularized incised plate urethroplasty in the ...

    African Journals Online (AJOL)

    Background: The outcomes of urethroplasty in the management of different types of hypospadias have continued to improve since the introduction of the tubularized incised plate (TIP) urethroplasty (Snodgrass method). The aim of this study was to evaluate the feasibility and applicability of TIP urethroplasty in the ...

  13. Feasibility of a tubularised incised-plate urethroplasty with double ...

    African Journals Online (AJOL)

    Background: Reoperation for failed hypospadias has been considered to be seriously problematic. The dense fibrotic tissue causes difficulties in wound healing and increases the rate of complications. The tubularised incised-plate urethroplasty (TIPU) method has become a preferred method for all varieties of hypospadias ...

  14. Combined use of Mathieu and incised plate technique (Snodgrass ...

    African Journals Online (AJOL)

    Objectives: To evaluate the results and complications after combined use of Mathieu and incised plate technique for management of distal hypospadias in older children. Patients and methods: A total of 33 patients with primary distal penile hypospadias were operated upon using the Mathieu technique combined with deep ...

  15. Tubularized incised plate technique for recurrent hypospadias: a ...

    African Journals Online (AJOL)

    Annals of Pediatric Surgery 2012, 8:80–85. Keywords: recurrent hypospadias, salvage hypospadias, tubularized incised plate. aDepartment of Surgery, Division of Pediatric and Plastic Surgery, Faculty of. Medicine, Suez Canal University, Ismailia and bDepartment of Surgery, Faculty of. Medicine, Menoufia University ...

  16. a comparative study between manual small incision cataract surgery ...

    African Journals Online (AJOL)

    ... October 2012 to October 2014 for cataract surgery were followed up for 6 weeks after surgery. They were divided into two groups based on the type of surgical procedure opted by the patients. Group A consisted of 50 patients who underwent Manual Small Incision Cataract. Surgery with rigid Polymethyl Methacrylate IOL ...

  17. Anastomosis Procedure through an Inguinal Hernia Incision in ...

    African Journals Online (AJOL)

    was laparoscopically transected by a stapler. A 4 cm skin incision was then made in the left inguinal region and carried down to the peritoneum through the hernia sac [Figure 1]. Bowel resection was performed extracorporeally, and an anvil was placed at the proximal end of the colon, over a purse-string suture. [Figure 2].

  18. rubularised Incised Plate Hypospadias Urethroplasty In A Regional ...

    African Journals Online (AJOL)

    1t the Coast Province General Hospital in Mombasa. Xenya and in some private hospitals, nearby. junction. Artificial erection test is done to check for residual chordee20. Residual penile curvature is corrected by dorsal tunica albuginea plication8. - The glans wings are mobilized laterally. A midline relaxing incision is made ...

  19. Treatment of pharyngocutaneous fistula acquired from incisions and ...

    African Journals Online (AJOL)

    Treatment of pharyngocutaneous fistula acquired from incisions and drainage of deep neck space abscess in a patient with occult third branchial anomaly. ... We did surgical exploration to excise and close the fistula but only succeeded at the second attempt. Conclusion: We conclude that branchial apparatus anomaly ...

  20. Single-incision laparoscopic surgery for pyloric stenosis.

    Science.gov (United States)

    Kozlov, Yury; Novogilov, Vladimir; Podkamenev, Alexey; Rasputin, Andrey; Weber, Irina; Solovjev, Alexey; Yurkov, Pavel

    2012-04-01

    Laparoscopy is the most common procedure for correction of congenital pyloric stenosis. The standard laparoscopic approach is based on the three-port technique. In contrast to the standard laparoscopic technique, the single-incision laparoscopic surgery (SILS) requires only one incision. We report on our experience with this surgical approach. Between September 2009 and August 2010 a total of 24 children underwent a laparoscopic pyloromyotomy, 12 in SILS technique. The single incision was carried through the center of the umbilicus. The working instruments were introduced in a two-dimensional direction into the peritoneal cavity via the same umbilical incision. The two groups were compared for patients' demographics, operative report and early postoperative outcomes. All SILS procedures were performed successfully with no conversion rate. There were no differences in the preoperative parameters between the two groups regarding age before surgery and body weight at operation. Operative time and time of full enteral intake was similar to comparable procedures with usage of a standard laparoscopic approach. There were no operative or postoperative complications. The early experience described in this study confirms that SILS can be applied for treatment of pyloric stenosis with outcomes similar to the standard laparoscopic surgery.

  1. Better outcome from arthroscopic partial meniscectomy than skin incisions only?

    DEFF Research Database (Denmark)

    Roos, Ewa M; Hare, Kristoffer Borbjerg; Nielsen, Sabrina Mai

    2018-01-01

    OBJECTIVE: Compare arthroscopic partial meniscectomy to a true sham intervention. METHODS: Sham-controlled superiority trial performed in three county hospitals in Denmark comparing arthroscopic partial meniscectomy to skin incisions only in patients aged 35-55 years with persistent knee pain and...

  2. Feasibility of reduced port surgery applying Higuchi's transverse incision

    Directory of Open Access Journals (Sweden)

    Kazu Ueda

    2017-02-01

    Conclusion: We reported novel forms of reduced port surgery applying Higuchi's transverse incision. It was suggested that these procedures are relatively simple, but ensure the same safety and efficacy as conventional methods. We intend to increase the number of cases and examine safety, efficacy, and patient satisfaction for these procedures.

  3. Short communication Combined use of Mathieu and incised plate ...

    African Journals Online (AJOL)

    Objectives: To evaluate the results and complications after combined use of Mathieu and incised plate technique for management of distal hypospadias in older children. Patients and methods: A total of 33 patients with primary distal penile hypospadias were operated upon using the Mathieu technique combined with deep ...

  4. Topical‑intracameral anesthesia in manual small incision cataract ...

    African Journals Online (AJOL)

    Background: Cataract remains a leading cause of blindness worldwide. Manual small incision cataract surgery (MSICS) is currently practiced as the technique of choice in Sub‑Saharan Africa to reduce the backlog of cataract blindness. Optimal pain control during surgery remains a challenge to cataract surgeons. Aim: To ...

  5. Visual Outcome after Small Incision Cataract Surgery in ...

    African Journals Online (AJOL)

    Objective: The aim of this study was to determine the visual outcome of patients who had manual small incision cataract surgery in a high volume secondary eye hospital in southwestern Nigeria, and to identify reasons for poor outcome. Methodology: This is an observational descriptive, longitudinal study of consecutive ...

  6. Ankle fusion using a 2-incision, 3-screw technique

    NARCIS (Netherlands)

    Hendrickx, R. P. M.; Kerkhoffs, G. M. M. J.; Stufkens, S. A. S.; van Dijk, C. N.; Marti, R. K.

    2011-01-01

    Reliable fusion and optimal correction of the alignment of the ankle joint using a 2-incision, 3-screw technique. Symptomatic osteoarthritis of the ankle joint after insufficient other treatment, severe deformity of the osteoarthritic ankle joint, or salvation procedure after failed arthroplasty.

  7. DOES CONJUNCTIVAL INCISION INFLUENCE MEDIAL RECTUS MUSCLE RECESSIONS?

    Directory of Open Access Journals (Sweden)

    Galina G. Dimitrova

    2015-09-01

    Full Text Available Purpose: To evaluate the role of conjunctival incision in medial rectus muscle recessions as surgical treatment of choice in esotropia. Methods: The study included 200 patients (370 eyes, operated on for esotropia in the period of 2000-2014. 170 of them (340 eyes underwent bilateral medial rectus muscle recessions and 30- unilateral medial rectus muscle recession for various forms of alternating/alternated esotropia. We compared the effect (Δ/mm recession of fornix and limbal approach. Diagnostic, surgical and statistical methods were used. Results: Limbal incision was performed on 110 patients (55,3% and fornix approach was done in 89 cases (44,7%. The mean effect corrected prism diopters for each mm of recession (Δ/mm differed significantly in the two groups, being bigger in cases with fornix incision (p<0,001 . Conclusion: The type of conjunctival incision in medial rectus muscle recessions have an influence not only on the cosmetic appearance, but also on the functional result. This is especially true for large recessions.

  8. A Fluorescent Probe to Measure DNA Damage and Repair.

    Directory of Open Access Journals (Sweden)

    Allison G Condie

    Full Text Available DNA damage and repair is a fundamental process that plays an important role in cancer treatment. Base excision repair (BER is a major repair pathway that often leads to drug resistance in DNA-targeted cancer chemotherapy. In order to measure BER, we have developed a near infrared (NIR fluorescent probe. This probe binds to a key intermediate, termed apurinic/apyrimidinic (AP site, in the BER pathway where DNA damage and repair occurs. We have developed an assay to show the efficacy of the probe binding to AP sites and have shown that it can distinguish AP sites in DNA extract from chemotherapy treated cells. This probe has potential application in monitoring patient response to chemotherapy and evaluating new drugs in development.

  9. Discrimination of Finger Area of Somatosensory Cortex by NIRS

    Science.gov (United States)

    Xu, Mingdi; Hayami, Takehito; Iramina, Keiji

    We carried out a near-infrared spectroscopy (NIRS) study to observe the hemodynamic responses associated with cortical activation in the primary somatosensory cortex (SI) by finger electrical stimulation. We examined whether NIRS can assist in investigating the somatotopic arrangement of fingers on the SI hand area. We found that although relatively low in spatial resolution, NIRS can to some extent help to discriminate the representations of thumb and ring finger on the SI hand area.

  10. The histone acetyltransferase inhibitor Nir regulates epidermis development.

    Science.gov (United States)

    Duteil, Delphine; Tourrette, Yves; Eberlin, Adrien; Willmann, Dominica; Patel, Dharmeshkumar; Friedrichs, Nicolaus; Müller, Judith M; Schüle, Roland

    2018-03-21

    In addition to its function as an inhibitor of histone acetyltransferases, Nir (Noc2l) binds to p53 and TAp63 to regulate their activity. Here, we show that epidermis-specific ablation of Nir impairs epidermal stratification and barrier function, resulting in perinatal lethality. Nir-deficient epidermis lacks appendages and remains single layered during embryogenesis. Cell proliferation is inhibited, whereas apoptosis and p53 acetylation are increased, indicating that Nir is controlling cell proliferation by limiting p53 acetylation. Transcriptome analysis revealed that Nir regulates the expression of essential factors in epidermis development, such as keratins, integrins and laminins. Furthermore, Nir binds to and controls the expression of p63 and limits H3K18ac at the p63 promoter. Corroborating the stratification defects, asymmetric cell divisions were virtually absent in Nir-deficient mice, suggesting that Nir is required for correct mitotic spindle orientation. In summary, our data define Nir as a key regulator of skin development. © 2018. Published by The Company of Biologists Ltd.

  11. Food quality assessment by NIR hyperspectral imaging

    Science.gov (United States)

    Whitworth, Martin B.; Millar, Samuel J.; Chau, Astor

    2010-04-01

    Near infrared reflectance (NIR) spectroscopy is well established in the food industry for rapid compositional analysis of bulk samples. NIR hyperspectral imaging provides new opportunities to measure the spatial distribution of components such as moisture and fat, and to identify and measure specific regions of composite samples. An NIR hyperspectral imaging system has been constructed for food research applications, incorporating a SWIR camera with a cooled 14 bit HgCdTe detector and N25E spectrograph (Specim Ltd, Finland). Samples are scanned in a pushbroom mode using a motorised stage. The system has a spectral resolution of 256 pixels covering a range of 970-2500 nm and a spatial resolution of 320 pixels covering a swathe adjustable from 8 to 300 mm. Images are acquired at a rate of up to 100 lines s-1, enabling samples to be scanned within a few seconds. Data are captured using SpectralCube software (Specim) and analysed using ENVI and IDL (ITT Visual Information Solutions). Several food applications are presented. The strength of individual absorbance bands enables the distribution of particular components to be assessed. Examples are shown for detection of added gluten in wheat flour and to study the effect of processing conditions on fat distribution in chips/French fries. More detailed quantitative calibrations have been developed to study evolution of the moisture distribution in baguettes during storage at different humidities, to assess freshness of fish using measurements of whole cod and fillets, and for prediction of beef quality by identification and separate measurement of lean and fat regions.

  12. Brain aneurysm repair

    Science.gov (United States)

    ... aneurysm repair; Dissecting aneurysm repair; Endovascular aneurysm repair - brain; Subarachnoid hemorrhage - aneurysm ... Your scalp, skull, and the coverings of the brain are opened. A metal clip is placed at ...

  13. On the terminology of the spectral vegetation index (NIR – SWIR)/(NIR + SWIR)

    Science.gov (United States)

    Ji, Lel; Zhang, Li; Wylie, Bruce K.; Rover, Jennifer R.

    2011-01-01

    The spectral vegetation index (ρNIR – ρSWIR)/(ρNIR + ρSWIR), where ρNIR and ρSWIR are the near-infrared (NIR) and shortwave-infrared (SWIR) reflectances, respectively, has been widely used to indicate vegetation moisture condition. This index has multiple names in the literature, including infrared index (II), normalized difference infrared index (NDII), normalized difference water index (NDWI), normalized difference moisture index (NDMI), land surface water index (LSWI), and normalized burn ratio (NBR), etc. After reviewing each term’s definition, associated sensors, and channel specifications, we found that the index consists of three variants, differing only in the SWIR region (1.2–1.3 µm, 1.55–1.75 µm, or 2.05–2.45 µm). Thus, three terms are sufficient to represent these three SWIR variants; other names are redundant and therefore unnecessary. Considering the spectral representativeness, the term’s popularity, and the “rule of priority” in scientific nomenclature, NDWI, NDII, and NBR, each corresponding to the three SWIR regions, are more preferable terms.

  14. Incisional hernia after upper abdominal surgery: A randomised controlled trial of midline versus transverse incision

    NARCIS (Netherlands)

    J.A. Halm (Jens); H. Lip (Harm); P.I.M. Schmitz (Paul); J. Jeekel (Hans)

    2009-01-01

    textabstractObjectives: To determine whether a transverse incision is an alternative to a midline incision in terms of incisional hernia incidence, surgical site infection, postoperative pain, hospital stay and cosmetics in cholecystectomy. Summary background data: Incisional hernias after midline

  15. Mismatch Repair*

    Science.gov (United States)

    Fishel, Richard

    2015-01-01

    Highly conserved MutS homologs (MSH) and MutL homologs (MLH/PMS) are the fundamental components of mismatch repair (MMR). After decades of debate, it appears clear that the MSH proteins initiate MMR by recognizing a mismatch and forming multiple extremely stable ATP-bound sliding clamps that diffuse without hydrolysis along the adjacent DNA. The function(s) of MLH/PMS proteins is less clear, although they too bind ATP and are targeted to MMR by MSH sliding clamps. Structural analysis combined with recent real-time single molecule and cellular imaging technologies are providing new and detailed insight into the thermal-driven motions that animate the complete MMR mechanism. PMID:26354434

  16. DNA repair , cell repair and radiosensitivity

    International Nuclear Information System (INIS)

    Zhestyanikov, V.D.

    1983-01-01

    Data obtained in laboratory of radiation cytology and literature data testifying to a considerable role of DNA repair in cell sensitivity to radiation and chemical DNA-tropic agents have been considered. Data pointing to the probability of contribution of inducible repair of DNA into plant cells sensitivity to X-rays are obtained. Certain violations of DNA repair do not result in the increase of radiosensitivity. It is assumed that in the cases unknown mechanisms of DNA repair operate

  17. Functional and aesthetic results of various lip-splitting incisions: A clinical analysis of 60 cases.

    Science.gov (United States)

    Rapidis, A D; Valsamis, S; Anterriotis, D A; Skouteris, C A

    2001-11-01

    This study retrospectively evaluated the functional and aesthetic results of various types of lip-splitting incisions in a group of patients in whom this approach was used to treat intraoral tumors. Between 1992 and 1998, 87 consecutive patients were subjected to either mandibulotomy or mandibulectomy using a lip-splitting incision. During this period, 4 types of incisions were sequentially used: straight midline incision, lateral lip-splitting incision, midline splitting with extension around the contour of the chin, and the chevron chin-contour incision. Sixty patients with a follow-up of at least 6 months were included in the study. The patients were asked to answer a questionnaire regarding the degree of satisfaction with the cosmetic result of the procedure and were clinically assessed for sensory and functional impairment resulting from the incision. The remaining 27 patients were lost to follow-up or had died of their disease. The lateral lip-splitting incision caused the fewest postoperative problems in patients subjected to either mandibulotomy or mandibulectomy. The best overall results were achieved by the chevron-chin contour incision. The incision that followed the contour of the chin and the straight midline incision showed less satisfactory results. The chevron chin-contour incision, along with meticulous soft tissue closure, produces the best aesthetic and functional results. Copyright 2001 American Association of Oral and Maxillofacial Surgeons

  18. The cutting edges in DNA repair, licensing, and fidelity: DNA and RNA repair nucleases sculpt DNA to measure twice, cut once.

    Science.gov (United States)

    Tsutakawa, Susan E; Lafrance-Vanasse, Julien; Tainer, John A

    2014-07-01

    To avoid genome instability, DNA repair nucleases must precisely target the correct damaged substrate before they are licensed to incise. Damage identification is a challenge for all DNA damage response proteins, but especially for nucleases that cut the DNA and necessarily create a cleaved DNA repair intermediate, likely more toxic than the initial damage. How do these enzymes achieve exquisite specificity without specific sequence recognition or, in some cases, without a non-canonical DNA nucleotide? Combined structural, biochemical, and biological analyses of repair nucleases are revealing their molecular tools for damage verification and safeguarding against inadvertent incision. Surprisingly, these enzymes also often act on RNA, which deserves more attention. Here, we review protein-DNA structures for nucleases involved in replication, base excision repair, mismatch repair, double strand break repair (DSBR), and telomere maintenance: apurinic/apyrimidinic endonuclease 1 (APE1), Endonuclease IV (Nfo), tyrosyl DNA phosphodiesterase (TDP2), UV Damage endonuclease (UVDE), very short patch repair endonuclease (Vsr), Endonuclease V (Nfi), Flap endonuclease 1 (FEN1), exonuclease 1 (Exo1), RNase T and Meiotic recombination 11 (Mre11). DNA and RNA structure-sensing nucleases are essential to life with roles in DNA replication, repair, and transcription. Increasingly these enzymes are employed as advanced tools for synthetic biology and as targets for cancer prognosis and interventions. Currently their structural biology is most fully illuminated for DNA repair, which is also essential to life. How DNA repair enzymes maintain genome fidelity is one of the DNA double helix secrets missed by James Watson and Francis Crick, that is only now being illuminated though structural biology and mutational analyses. Structures reveal motifs for repair nucleases and mechanisms whereby these enzymes follow the old carpenter adage: measure twice, cut once. Furthermore, to measure

  19. Dorsal inlay inner preputial graft for primary hypospadias repair

    Directory of Open Access Journals (Sweden)

    Rajendra B. Nerli

    2014-01-01

    Full Text Available Background: The most commonly performed operation to repair distal hypospadias is the Tubularised incised plate (TIP repair. The key step is midline incision of the urethral plate, which widens a narrow plate and converts a flat into a deep plate groove, ensuring a vertical, slit neomeatus and a normal-calibre neourethra. At times in cases of proximal hypospadias, the urethral plate is very narrow and needs to be augmented or substituted for further tubularisation. We report our experience with primary single stage dorsal inlay urethroplasty using preputial skin grafts. Patients and Methods: Children with proximal hypospadias with a narrow urethral plate formed the study group. Children needing transection of the urethral plate, having undergone circumcision/hypospadias repair previously or having an inadequate prepuce was excluded. Results: Twelve children with a mean age of 48.83 months underwent primary dorsal inlay preputial graft urethroplasty for proximal hypospadias with a very narrow urethral plate. At an average follow-up of 42.16 months, 2 (16.66% children had a breakdown of ventral shaft skin. None of the children had meatal stenosis, and none of these 12 children developed urethrocutaneous fistula. Conclusion: Primary dorsal inlay inner preputial graft urethroplasty successfully fulfills all traditional hypospadias repair criteria. It offers a viable, safe, rapid and easy option in the management of proximal hypospadias with a narrow urethral plate.

  20. Base excision repair of DNA in γ-irradiated human cells

    International Nuclear Information System (INIS)

    Moran, M.F.; Ebisuzaki, Kaney

    1987-01-01

    Escherichia coli endonuclease IV was used to incise cellular DNA specifically at apurinic/apyrimidinic (AP) sites prior to alkaline elution to measure the resulting DNA strand breaks. γ-Irradiated HeLa cells initially contained DNA strand breaks and no AP sites. Upon incubation at 37 0 C the strand breaks were rapidly repaired and AP sites were generated and subsequently repaired. The transient nature of the AP sites indicates the in vivo operation of a base excision repair pathway whereby damaged bases are removed from DNA by DNA glycosylases to produce AP intermediates that are then substrates for AP endonucleases. (author)

  1. T-Fix endoscopic meniscal repair: technique and approach to different types of tears.

    Science.gov (United States)

    Barrett, G R; Richardson, K; Koenig, V

    1995-04-01

    Endoscopic meniscus repair using the T-Fix suture device (Acufex Microsurgical, Inc, Mansfield, MA) allows ease of suture placement for meniscus stability without the problems associated with ancillary incisions such as neurovascular compromise. It is ideal for the central posterior horn tears that are difficult using conventional techniques. Vertical tears, bucket handle tears, flap tears, and horizontal tears can be approached using a temporary "anchor stitch" to stabilize the meniscus before T-Fix repair. The basic method of repair and our approach to these different types of tears is presented.

  2. Incision of Licus Vallis, Mars, From Multiple Lake Overflow Floods

    Science.gov (United States)

    Goudge, Timothy A.; Fassett, Caleb I.

    2018-02-01

    Licus Vallis is a large valley (>350 km long, >2 km wide, and >150 m deep) that heads at the outlet breach of an 30 km diameter impact crater. We present observations of the geomorphology and topography of this paleolake outlet valley and associated tributary valleys to constrain the history of incision of the Licus Vallis system. Licus Vallis has an abrupt increase in gradient by a factor of approximately 4 along its longitudinal profile, and a knickpoint that drops 200 m over a reach of 2 km approximately 12 km downstream from the valley head. We also describe a set of paired terraces within Licus Vallis, which are continuous for tens of kilometers and define an interior valley >2 km in width. We interpret the geomorphology of Licus Vallis as recording at least two discrete, major episodes of valley incision, both driven by lake overflow floods. The main portion of Licus Vallis formed by overflow flooding from a large ( 103-104 km2) lake contained in an intercrater basin. Subsequently, overflow flooding from a lake within the 30 km diameter impact crater reactivated Licus Vallis, forming a major knickpoint at the valley head and establishing the upstream section of the valley at a lower slope. Farther down the valley, this flood event incised an interior valley bounded by paired terraces. Regional tributary valleys that feed Licus Vallis also have prominent knickpoints, which have retreated farthest for downstream valleys. We conclude that these knickpoints record successive waves of incision that swept up Licus Vallis during lake overflow flooding, with erosion in the main trunk of the valley (from overflow floods) significantly outpacing erosion in the tributary valleys (from regional surface runoff). These observations of Licus Vallis illustrate how lake overflow floods may have provided an important control on the pace of landscape evolution on Mars.

  3. Robot-assisted submandibular gland excision via modified facelift incision

    OpenAIRE

    Jung, Seung Wook; Kim, Young Kwan; Cha, Yong Hoon; Koh, Yoon Woo; Nam, Woong

    2017-01-01

    Background The conventional transcervical resection for submandibular gland disease has some risks and an unsatisfactory cosmetic result. Recently, robot-assisted surgery has been developed as a plausible substitute for conventional surgery which provides an excellent cosmetic outcome. Case presentation The authors performed robot-assisted sialadenectomy via modified facelift incision using the da Vinci Xi surgical system (Intuitive Surgical Inc., CA, USA) with two endowrist arms (monopolar c...

  4. Rehabilitation of anterior teeth with customised incisal guide table.

    Science.gov (United States)

    Mall, Priyanka; Singh, Kamleshwar; Rao, Jitendra; Kumar, Lakshya

    2013-05-24

    Restoration of anterior guidance is a major challenge to the clinician in planning of all restorative treatments. An accurate anterior guidance is important for proper function, aesthetics, comfort and phonetics. This article describes anterior rehabilitation of a patient who met with a road traffic accident and lost his anterior teeth. Anterior guidance developed in the provisional restorations was accurately recorded in the customised incisal guide table and permanent restorations were fabricated accordingly.

  5. Rehabilitation of anterior teeth with customised incisal guide table

    OpenAIRE

    Mall, Priyanka; Singh, Kamleshwar; Rao, Jitendra; Kumar, Lakshya

    2013-01-01

    Restoration of anterior guidance is a major challenge to the clinician in planning of all restorative treatments. An accurate anterior guidance is important for proper function, aesthetics, comfort and phonetics. This article describes anterior rehabilitation of a patient who met with a road traffic accident and lost his anterior teeth. Anterior guidance developed in the provisional restorations was accurately recorded in the customised incisal guide table and permanent restorations were fabr...

  6. Rehabilitation of anterior teeth with customised incisal guide table

    Science.gov (United States)

    Mall, Priyanka; Singh, Kamleshwar; Rao, Jitendra; Kumar, Lakshya

    2013-01-01

    Restoration of anterior guidance is a major challenge to the clinician in planning of all restorative treatments. An accurate anterior guidance is important for proper function, aesthetics, comfort and phonetics. This article describes anterior rehabilitation of a patient who met with a road traffic accident and lost his anterior teeth. Anterior guidance developed in the provisional restorations was accurately recorded in the customised incisal guide table and permanent restorations were fabricated accordingly. PMID:23709546

  7. Mini incision open pyeloplasty - Improvement in patient outcome

    Directory of Open Access Journals (Sweden)

    Vishwajeet Singh

    2015-10-01

    Full Text Available ABSTRACT Purpose: To assess the subjective and objective outcomes of mini-incision dismembered Anderson-Hynes pyeloplasty in the treatment of primary ureteropelvic junction obstruction (UPJO. Materials and Methods: Between January 2008 to January 2013, Anderson-Hynes pyeloplasty was performed in 71 patients diagnosed with primary UPJO. Small subcostal muscle splitting incision was used in all cases. Sixteen patients with renal calculi underwent concomitant pyelolithotomy. Subjective outcome was assessed using visual pain analogue score (VAS. For objective assessment, the improvement in differential renal function (DRF and radio-tracer wash out time (T1/2 on Tc-99m DTPA scan and decrease in hydronephrosis (HDN on renal ultrasound (USG and urography (IVU were assessed. Results: Mean incision length was 5.2 cm. The average operating time and postoperative hospital stay was 63 (52-124 minutes and 2.5 (2–6 days respectively. Concomitant renal calculi were successfully removed in all the patients. Overall complication rates were 8.4% and overall success rate was 98.6% at median follow-up of 16 months. There was significant improvement in pain score (p=0.0001 and significant decrease in HDN after the procedure. While preoperative mean T1/2 was 26.7±6.4 minutes, postoperative half-time decreased to 7.8±4.2 minutes at 6 months and to 6.7±3.3 minutes at 1 year. Mean pre-operative DRF was 26.45% and it was 31.38% and 33.19% at 6 months and 1 year respectively. Conclusions: Mini-incision pyeloplasty is a safe and effective technique with combined advantage of high success rates of standard open pyeloplasty with decreased morbidity of laparoscopic approach. Excellent functional and objective outcomes can be achieved without extra technical difficulty.

  8. Single incision laparoscopic hepatectomy: Advances in laparoscopic liver surgery.

    Science.gov (United States)

    Tayar, Claude; Claude, Tayar; Subar, Daren; Daren, Subar; Salloum, Chady; Chady, Salloum; Malek, Alexandre; Alexandre, Malek; Laurent, Alexis; Alexis, Laurent; Azoulay, Daniel; Daniel, Azoulay

    2014-01-01

    Laparoscopic liver surgery is now an established practice in many institutions. It is a safe and feasible approach in experienced hands. Single incision laparoscopic surgery (SILS) has been performed for cholecystectomies, nephrectomies, splenectomies and obesity surgery. However, the use of SILS in liver surgery has been rarely reported. We report our initial experience in seven patients on single incision laparoscopic hepatectomy (SILH). From October 2010 to September 2012, seven patients underwent single-incision laparoscopic liver surgery. The abdomen was approached through a 25 mm periumbilical incision. No supplemental ports were required. The liver was transected using a combination of LigaSure™ (Covidien-Valleylab. Boulder. USA), Harmonic Scalpel and Ligaclips (Ethicon Endo-Surgery, Inc.). Liver resection was successfully completed for the seven patients. The procedures consisted of two partial resections of segment three, two partial resections of segment five and three partial resections of segment six. The mean operative time was 98.3 min (range: 60-150 min) and the mean estimated blood loss was 57 ml (range: 25-150 ml). The postoperative courses were uneventful and the mean hospital stay was 5.1 days (range: 1-13 days). Pathology identified three benign and four malignant liver tumours with clear margins. SILH is a technically feasible and safe approach for wedge resections of the liver without oncological compromise and with favourable cosmetic results. This surgical technique requires relatively advanced laparoscopic skills. Further studies are needed to determine the potential advantages of this technique, apart from the better cosmetic result, compared to the conventional laparoscopic approach.

  9. Incisive papilla and positions of maxillary anterior teeth among ...

    African Journals Online (AJOL)

    Results: One hundred and twelve maxillary casts generated from participants aged 18-35 years (mean age 22.39±2.00 years), with well aligned arches were studied. The maxillary central incisor exhibited a mean of 14.93±1.52mm from the posterior limit of the incisive papilla while the inter-canine line scored a mean of ...

  10. Single incision laparoscopic hepatectomy: Advances in laparoscopic liver surgery

    Directory of Open Access Journals (Sweden)

    Tayar Claude

    2014-01-01

    Full Text Available Background: Laparoscopic liver surgery is now an established practice in many institutions. It is a safe and feasible approach in experienced hands. Single incision laparoscopic surgery (SILS has been performed for cholecystectomies, nephrectomies, splenectomies and obesity surgery. However, the use of SILS in liver surgery has been rarely reported. We report our initial experience in seven patients on single incision laparoscopic hepatectomy (SILH. Patients and Methods: From October 2010 to September 2012, seven patients underwent single-incision laparoscopic liver surgery. The abdomen was approached through a 25 mm periumbilical incision. No supplemental ports were required. The liver was transected using a combination of LigaSure TM (Covidien-Valleylab. Boulder. USA, Harmonic Scalpel and Ligaclips (Ethicon Endo-Surgery, Inc.. Results: Liver resection was successfully completed for the seven patients. The procedures consisted of two partial resections of segment three, two partial resections of segment five and three partial resections of segment six. The mean operative time was 98.3 min (range: 60-150 min and the mean estimated blood loss was 57 ml (range: 25-150 ml. The postoperative courses were uneventful and the mean hospital stay was 5.1 days (range: 1-13 days. Pathology identified three benign and four malignant liver tumours with clear margins. Conclusion: SILH is a technically feasible and safe approach for wedge resections of the liver without oncological compromise and with favourable cosmetic results. This surgical technique requires relatively advanced laparoscopic skills. Further studies are needed to determine the potential advantages of this technique, apart from the better cosmetic result, compared to the conventional laparoscopic approach.

  11. Omphalocele repair - series (image)

    Science.gov (United States)

    ... abdominal wall defect at the base of the umbilical cord (umbilicus); the infant is born with a sac ... stable. While the baby is deep asleep and pain-free (under general anesthesia) an incision is made ...

  12. Gastroschisis repair - series (image)

    Science.gov (United States)

    ... abdominal wall defect to the side of the umbilical cord (umbilicus). The infant is born with intestines protruding ... lungs. While the infant is deep asleep and pain-free (under general anesthesia) an incision is made ...

  13. Endoscope-assisted transoral thyroidectomy using a frenotomy incision.

    Science.gov (United States)

    Woo, Seung Hoon

    2014-05-01

    Natural orifice translumenal endoscopic surgery (NOTES(®); American Society for Gastrointestinal Endoscopy [Oak Brook, IL] and Society of American Gastrointestinal and Endoscopic Surgeons [Los Angeles, CA]) has generated excitement among surgeons as potentially scar-free surgery. We developed this technique while taking into consideration that it could also be applied to transoral thyroid surgery. We report the case of a 35-year-old woman with a 0.5×0.5-cm papillary thyroid microcarcinoma. We implemented a modified approach for the removal of the thyroid by using a frenotomy incision of the mouth, accompanied by an endoscope system. A modified approach for the removal of the thyroid was used on the patient. The total operating time was 120 minutes, and there were no specific complications. The patient continues to be free of any diseases 12 months after the excision. Thyroidectomy can be performed by a transoral endoscope-assisted approach through a frenotomy incision of the mouth. We describe the detailed procedures for an endoscope-assisted transoral thyroidectomy using a frenotomy incision.

  14. 3D NIR-II Molecular Imaging Distinguishes Targeted Organs with High-Performance NIR-II Bioconjugates.

    Science.gov (United States)

    Zhu, Shoujun; Herraiz, Sonia; Yue, Jingying; Zhang, Mingxi; Wan, Hao; Yang, Qinglai; Ma, Zhuoran; Wang, Yan; He, Jiahuan; Antaris, Alexander L; Zhong, Yeteng; Diao, Shuo; Feng, Yi; Zhou, Ying; Yu, Kuai; Hong, Guosong; Liang, Yongye; Hsueh, Aaron J; Dai, Hongjie

    2018-02-15

    Greatly reduced scattering in the second near-infrared (NIR-II) region (1000-1700 nm) opens up many new exciting avenues of bioimaging research, yet NIR-II fluorescence imaging is mostly implemented by using nontargeted fluorophores or wide-field imaging setups, limiting the signal-to-background ratio and imaging penetration depth due to poor specific binding and out-of-focus signals. A newly developed high-performance NIR-II bioconjugate enables targeted imaging of a specific organ in the living body with high quality. Combined with a home-built NIR-II confocal set-up, the enhanced imaging technique allows 900 µm-deep 3D organ imaging without tissue clearing techniques. Bioconjugation of two hormones to nonoverlapping NIR-II fluorophores facilitates two-color imaging of different receptors, demonstrating unprecedented multicolor live molecular imaging across the NIR-II window. This deep tissue imaging of specific receptors in live animals allows development of noninvasive molecular imaging of multifarious models of normal and neoplastic organs in vivo, beyond the traditional visible to NIR-I range. The developed NIR-II fluorescence microscopy will become a powerful imaging technique for deep tissue imaging without any physical sectioning or clearing treatment of the tissue. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Prediction of pork quality with near infrared spectroscopy (NIRS): 1. Feasibility and robustness of NIRS measurements at laboratory scale

    NARCIS (Netherlands)

    Kapper, C.; Klont, R.E.; Verdonk, J.M.A.J.; Urlings, H.A.P.

    2012-01-01

    The objective was to study prediction of pork quality by near infrared spectroscopy (NIRS) technology in the laboratory. A total of 131 commercial pork loin samples were measured with NIRS. Predictive equations were developed for drip loss %, colour L*, a*, b* and pH ultimate (pHu). Equations with

  16. Near Infrared (nir) Imaging for Nde

    Science.gov (United States)

    Diamond, G. G.; Pallav, P.; Hutchins, D. A.

    2008-02-01

    A novel application of near infrared (NIR) signals is presented, which can be used to provide images of many different materials and objects. It is effectively a very low cost non-ionising alternative to many applications currently being investigated using electromagnetic waves at other frequencies, such as THz and X-ray imaging. This alternative technique can be realised by very simple and inexpensive electronics and is inherently far more portable and easy to use. Transmission imaging results from this technique are presented from examples industrial quality control, food inspection and various security applications, and the results compared to existing techniques. In addition, this technique can be used in through-transmission mode on biological and medical samples, and images are presented that differentiate between not only flesh and bone, but also various types of soft tissue.

  17. Diseno y construccion de un espectrometro NIR; Design and construction of a NIR spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Barcala Riveira, J. M.; Fernandez Marron, J. L.; Alberdi Primicia, J.; Molero Menendez, F.; Navarrete Marin, J. J.; Oller Gonzalez, J. C.

    2003-07-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs.

  18. Gamma-ray induced inhibition of DNA synthesis in ataxia telangiectasia fibroblasts is a function of excision repair capacity

    International Nuclear Information System (INIS)

    Smith, P.J.; Paterson, M.C.

    1980-01-01

    The extent of the deficiency in γ-ray induced DNA repair synthesis in an ataxia telangiectasia (AT) human fibroblast strain was found to show no oxygen enhancement, consistent with a defect in the repair of base damage. Repair deficiency, but not repair proficiency, in AT cells was accompanied by a lack of inhibition of DNA synthesis by either γ-rays or the radiomimetic drug bleomycin. Experiments with 4-nitroquinoline 1-oxide indicated that lack of inhibition was specific for radiogenic-type damage. Thus excision repair, perhaps by DNA strand incision or chromatin modification, appears to halt replicon initiation in irradiated repair proficient cells whereas in repair defective AT strains this putatively important biological function is inoperative

  19. NIRS-based noninvasive cerebrovascular regulation assessment

    Science.gov (United States)

    Miller, S.; Richmond, I.; Borgos, J.; Mitra, K.

    2016-03-01

    Alterations to cerebral blood flow (CBF) have been implicated in diverse neurological conditions, including mild traumatic brain injury, microgravity induced intracranial pressure (ICP) increases, mild cognitive impairment, and Alzheimer's disease. Near infrared spectroscopy (NIRS)-measured regional cerebral tissue oxygen saturation (rSO2) provides an estimate of oxygenation of the interrogated cerebral volume that is useful in identifying trends and changes in oxygen supply to cerebral tissue and has been used to monitor cerebrovascular function during surgery and ventilation. In this study, CO2-inhalation-based hypercapnic breathing challenges were used as a tool to simulate CBF dysregulation, and NIRS was used to monitor the CBF autoregulatory response. A breathing circuit for the selective administration of CO2-compressed air mixtures was designed and used to assess CBF regulatory responses to hypercapnia in 26 healthy young adults using non-invasive methods and real-time sensors. After a 5 or 10 minute baseline period, 1 to 3 hypercapnic challenges of 5 or 10 minutes duration were delivered to each subject while rSO2, partial pressure of end tidal CO2 (PETCO2), and vital signs were continuously monitored. Change in rSO2 measurements from pre- to intrachallenge (ΔrSO2) detected periods of hypercapnic challenges. Subjects were grouped into three exercise factor levels (hr/wk), 1: 0, 2:>0 and 10. Exercise factor level 3 subjects showed significantly greater ΔrSO2 responses to CO2 challenges than level 2 and 1 subjects. No significant difference in ΔPETCO2 existed between these factor levels. Establishing baseline values of rSO2 in clinical practice may be useful in early detection of CBF changes.

  20. Cosmetic Outcome of Tubularized Incised Plate Depends on The Type of Hypospadias: A Case Control Study

    Directory of Open Access Journals (Sweden)

    Gede Wirya Kusuma Duarsa

    2016-08-01

    Full Text Available Background: Recent studies show Tubularized Incised Plate (TIP urethroplasty, commonly used for distal hypospadias repair, can be used in proximal hypospadias with a decent success rate. It was contented that the age of the patient when undertook the surgery influences the outcome, with young age gaining more favourable outcome than the older. One the objectives of hypospadias repair is the cosmetic outcome, which can be evaluated using Hypospadias Objective Penile Evaluation (HOPE questionnaires. Our objective is to compare the proportion of the young and the older patients based on the cosmetic surgical outcome. Methods: In Sanglah General Hospital, Denpasar, 38 patients who had undergone a TIP urethroplasty from January 2012 until December 2015 were evaluated using HOPE questionnaires. Results: The sample are divided into two equally-numbered groups based on the HOPE total score. The median of the age of the subjects when they undergone the surgery is 4.8 years (1.89-18.10. The proportion of the over 5 year old in the cosmetically unsatisfying group (case is the same as the proportion in the cosmetically satisfying group (control, 52.63%, EOR=1 (p>0.05. The proportion based on the year of surgery are different, but not statistically significant (p>0.05. Based on the type of hypospadias, the proportion of subjects with proximal hypospadias in the case group is more than in the control group, EOR=14.95 (p<0.05. It shows proximal hypospadias is a risk factor for cosmetically unsatisfying result post TIP urethroplasty. Conclusions: It should be taken into account that TIP in proximal hypospadias has a greater risk to produce an unsatisfying cosmetical result.

  1. In vivo architectural analysis of clear corneal incisions using anterior segment optical coherence tomography.

    Science.gov (United States)

    Dupont-Monod, Sylvère; Labbé, Antoine; Fayol, Nicolas; Chassignol, Alexis; Bourges, Jean-Louis; Baudouin, Christophe

    2009-03-01

    To use anterior segment optical coherence tomography (AS-OCT) to analyze the in vivo architecture of clear corneal incisions after phacoemulsification using different techniques. Department of Ophthalmology, Quinze-Vingts National Ophthalmology Hospital, Paris, France. This prospective observational study analyzed clear corneal incisions used in phacoemulsification. All wounds were evaluated 1 day and 8 days postoperatively by AS-OCT (Visante). Incision architecture and pachymetry at the wound level were analyzed. Thirty-five clear corneal incisions were analyzed. Six eyes had 2.75 mm coaxial phacoemulsification, 19 had 2.20 mm microincision coaxial phacoemulsification, and 10 had 1.30 mm bimanual microincision phacoemulsification. The 1.30 mm incision had a straight-line configuration. The 2.20 mm and 2.75 mm incisions had an arcuate configuration. The angles of incidence of 1.30 mm incisions were greater than those of 2.20 mm incisions (P<.001). All incisions had slight corneal edema limited to the incision area. The edema was slightly greater around 1.30 mm incisions (mean pachymetry 1143 microm +/- 140 [SD]) than around 2.20 mm incisions (mean 1012 +/- 101 microm) (P = .001). Bimanual procedures had satisfactory endothelial apposition in the enlarged areas, where stromal edema was less than that surrounding the unenlarged 1.30 mm incisions. The 3 phacoemulsification techniques induced gaping of the endothelial edge, minor inadequate endothelial apposition, and mild stromal edema in the area of the clear corneal incisions. Bimanual microincision sleeveless phacoemulsification may alter the wound slightly more than coaxial 2.75 mm and microcoaxial 2.20 mm sleeved-tip phacoemulsification.

  2. Vascularized dorsal dartos flap to prevent fistula in tubularized incised plate urethroplasty for primary distal and mid shaft hypospadias

    Directory of Open Access Journals (Sweden)

    A. K. M. Zahid Hossain

    2016-08-01

    Full Text Available The aim of the present study was to evaluate the importance of neourethral covering using vascularized dorsal flap for preventing fistula in Tabularized incised plate (TIP urethroplasty. The study included 52 children (aged 2-10 years who had hypospadias repaired including 44  with distal and 8  with mid shaft hypospadias. In all children, a standard tabularized incised plate urethroplasty was followed by reconstruction of new surrounding urethral tissue. A longitudinal dartos flap was harvested from excessive dorsal preputial and penile hypospadiac skin and transposed to ventral side by a buttonhole maneuver. It was sutured to the glans wings and the neomeatus and to the corpora covernosa over the neo-urethra. Thus the new urethra was completely covered with well-vascularzed subcutaneous tissue. At a mean follow-up of 18 months, the result was successful with no fistula or urethral stenosis, except 2 of the mid penile hypospadias. All patients had good functional and cosmetic results with straight penis and vertical slit shaped meatus at the tip of the penis. The 2 patients developed tiny fistula, which were closed spontaneously after meatal dilatation. In conclusion, urethral covering should be part of TIP urethroplasty. A dorsal well-vascularized dartos flap, button holed ventrally is a good choice for preventing fistula for distal and mid shaft hypospadias. 

  3. Multipurpose internal retractor for Single-incision surgery (SIS): single-institution case series.

    Science.gov (United States)

    Galvani, Carlos A; Garza, Ulises; Echeverria, Angela; Kaul, Amit; Samamé, Julia

    2014-04-01

    Single-incision laparoscopic surgery (SIS) is less invasive than standard laparoscopic surgery; however, it is more difficult due to restriction of motion and the impossibility to use assistants. To overcome these obstacles, we developed a self-sustaining multipurpose internal retractor by attaching a Lone Star retractor hook to a laparoscopic bulldog clamp. Herein, we report our SIS experience using our novel retractor. Between October 2008 and April 2011, 104 patients underwent SIS using the internal retractor: 67 bandings (43% simultaneous hiatal hernia repair), 8 sleeve gastrectomies, 27 cholecystectomies, and 2 Nissen fundoplication. Mean age was 40 (range, 21 to 85) and mean body mass index was 40 kg/m (range, 20 to 64 kg/m). No intraoperative complications were observed from the use of the retractor but 2 cases required additional retraction due to liver size. This retractor has been successfully used for different SIS procedures showing to be safe, adaptable, and easy to use, lessening some challenges of SIS.

  4. Portable wide-field hand-held NIR scanner

    Science.gov (United States)

    Jung, Young-Jin; Roman, Manuela; Carrasquilla, Jennifer; Erickson, Sarah J.; Godavarty, Anuradha

    2013-03-01

    Near-infrared (NIR) optical imaging modality is one of the widely used medical imaging techniques for breast cancer imaging, functional brain mapping, and many other applications. However, conventional NIR imaging systems are bulky and expensive, thereby limiting their accelerated clinical translation. Herein a new compact (6 × 7 × 12 cm3), cost-effective, and wide-field NIR scanner has been developed towards contact as well as no-contact based real-time imaging in both reflectance and transmission mode. The scanner mainly consists of an NIR source light (between 700- 900 nm), an NIR sensitive CCD camera, and a custom-developed image acquisition and processing software to image an area of 12 cm2. Phantom experiments have been conducted to estimate the feasibility of diffuse optical imaging by using Indian-Ink as absorption-based contrast agents. As a result, the developed NIR system measured the light intensity change in absorption-contrasted target up to 4 cm depth under transillumination mode. Preliminary in-vivo studies demonstrated the feasibility of real-time monitoring of blood flow changes. Currently, extensive in-vivo studies are carried out using the ultra-portable NIR scanner in order to assess the potential of the imager towards breast imaging..

  5. Time domain functional NIRS imaging for human brain mapping.

    Science.gov (United States)

    Torricelli, Alessandro; Contini, Davide; Pifferi, Antonio; Caffini, Matteo; Re, Rebecca; Zucchelli, Lucia; Spinelli, Lorenzo

    2014-01-15

    This review is aimed at presenting the state-of-the-art of time domain (TD) functional near-infrared spectroscopy (fNIRS). We first introduce the physical principles, the basics of modeling and data analysis. Basic instrumentation components (light sources, detection techniques, and delivery and collection systems) of a TD fNIRS system are described. A survey of past, existing and next generation TD fNIRS systems used for research and clinical studies is presented. Performance assessment of TD fNIRS systems and standardization issues are also discussed. Main strengths and weakness of TD fNIRS are highlighted, also in comparison with continuous wave (CW) fNIRS. Issues like quantification of the hemodynamic response, penetration depth, depth selectivity, spatial resolution and contrast-to-noise ratio are critically examined, with the help of experimental results performed on phantoms or in vivo. Finally we give an account on the technological developments that would pave the way for a broader use of TD fNIRS in the neuroimaging community. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Biomechanical analysis of distal biceps tendon repair methods.

    Science.gov (United States)

    Henry, Jon; Feinblatt, Jeff; Kaeding, Christopher C; Latshaw, James; Litsky, Alan; Sibel, Roman; Stephens, Julie A; Jones, Grant L

    2007-11-01

    The 1-incision and 2-incision techniques are commonly used methods to repair a distal biceps rupture, and they differ in the location of reinsertion of tendon into bone. The native distal biceps brachii tendon inserts on the posterior-ulnar aspect of the bicipital tuberosity, which functions as a cam, increasing the tendon's moment arm during its principal action of forearm supination. Repair of the distal biceps tendon to the anterior aspect of the tuberosity compromises forearm supination due to absence of the bicipital tuberosity's cam effect. Controlled laboratory study. Eleven matched pairs of fresh-frozen cadaveric upper extremities were prepared for repair of the distal biceps tendon using either anterior or posterior reattachment with transosseous suture fixation. Specimens were tested on a materials testing machine with intact distal biceps insertion and after repair. A load cell at the distal radial-ulnar joint measured resultant elbow flexion and forearm supination torque produced by 100-N force applied to the proximal aspect of the tendon. Although there was a trend (P= .104) toward loss of supination torque with the anterior reconstruction method, no significant differences in torque (0.80 vs 0.89 N.m) or flexion force (11.87 vs 12.07 N) were found between the anterior and posterior reconstruction techniques. There is no statistically significant difference in flexion force or supination torque between the anterior and posterior reconstruction techniques. This study supports existing limited clinical data suggesting no functional differences exist between 2 common repair methods. Further biomechanical and clinical investigations directly comparing the results of distal biceps tendon repairs made to the anterior aspect versus the posterior aspect of the tuberosity are necessary to definitely determine if differences exist in resultant elbow flexion and forearm supination functions.

  7. One-incision versus two-incision techniques for arthroscopically assisted anterior cruciate ligament reconstruction in adults.

    Science.gov (United States)

    Rezende, Fernando C; Moraes, Vinícius Y; Franciozi, Carlos Es; Debieux, Pedro; Luzo, Marcus V; Belloti, João Carlos

    2017-12-15

    Anterior cruciate ligament (ACL) tears are serious knee injuries that are frequently treated surgically in the form of arthroscopically assisted reconstruction with grafts from the patella or hamstrings tendons. We reviewed the evidence for the choice of arthroscopically assisted ACL reconstruction technique in terms of whether it should involve one incision (femoral tunnel drilled from inside the knee joint under arthroscopic visualisation) or two incisions (femoral tunnel drilled from outside to inside the knee joint). To assess the effects (benefits and harms) of one-incision versus two-incision techniques for arthroscopically assisted ACL reconstruction in adults. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, Latin American and Caribbean Health Sciences (LILACS), the World Health Organization International Clinical Trials Registry Platform, ClinicalTrials.gov, reference lists, and conference abstracts. The date of the search was 16 August 2017. Randomised and quasi-randomised controlled clinical trials evaluating one-incision versus two-incision techniques for arthroscopically assisted ACL reconstruction in adults. Two review authors independently searched and selected studies, and extracted data and assessed the risk of bias of the eligible studies. We undertook limited pooling of data using the fixed-effect model. We included five trials (four randomised and one quasi-randomised) evaluating a total of 320 participants who were mainly in their 20s. All participants underwent ACL reconstruction with patella tendon grafts. All five included trials were at a high risk of bias, particularly performance bias. Based on these limitations and the insufficiency of the available data resulting in imprecision of effect estimates, we judged the quality of the evidence as very low for all outcomes. This means that we are uncertain of the findings of the

  8. Rapid road repair vehicle

    Science.gov (United States)

    Mara, Leo M.

    1998-01-01

    Disclosed is a rapid road repair vehicle capable of moving over a surface to be repaired at near normal posted traffic speeds to scan for and find an the high rate of speed, imperfections in the pavement surface, prepare the surface imperfection for repair by air pressure and vacuum cleaning, applying a correct amount of the correct patching material to effect the repair, smooth the resulting repaired surface, and catalog the location and quality of the repairs for maintenance records of the road surface. The rapid road repair vehicle can repair surface imperfections at lower cost, improved quality, at a higher rate of speed than was was heretofor possible, with significantly reduced exposure to safety and health hazards associated with this kind of road repair activities in the past.

  9. Intelligent MEMS spectral sensor for NIR applications (Conference Presentation)

    Science.gov (United States)

    Kantojärvi, Uula; Antila, Jarkko E.; Mäkynen, Jussi; Suhonen, Janne

    2017-05-01

    Near Infrared (NIR) spectrometers have been widely used in many material inspection applications, but mainly in central laboratories. The role of miniaturization, robustness of spectrometer and portability are really crucial when field inspection tools should be developed. We present an advanced spectral sensor based on a tunable Microelectromechanical (MEMS) Fabry-Perot Interferometer which will meet these requirements. We describe the wireless device design, operation principle and easy-to-use algorithms to adapt the sensor to number of applications. Multiple devices can be operated simultaneously and seamlessly through cloud connectivity. We also present some practical NIR applications carried out with truly portable NIR device.

  10. Pressure Irrigation of Surgical Incisions and Traumatic Wounds.

    Science.gov (United States)

    Fry, Donald E

    Pressure irrigation of surgical incisions and traumatic wounds is commonly used to prevent infections. Commercial pressure irrigation devices have proliferated rapidly, but scientific validation of clinical benefit or appropriate use remains uncertain. The published experimental and clinical investigations of pressure irrigation have been reviewed since the introduction of the Waterpik device in 1967 to identify the evidence for use to prevent soft tissue infections associated with injury wounds or surgical incisions. The published literature favors low pressure irrigation between 5-15 pounds/square inch (psi) for experimental removal of bacteria from contaminated tissues, with pressures higher being associated with soft tissue and bone injury. No experimental or clinical data have demonstrated improved benefit from pulsed over continuous lavage. Clinical studies have been very heterogeneous in patient populations and study design; meta-analysis was not feasible. High-risk abdominal operations may have lower surgical site infection rates with pressure irrigation. Pressure irrigation in fractures and joint replacement surgery has shown mixed results. The largest multi-center randomized trial showed no benefit of pulsed (8-10 psi) lavage over conventional continuous gravity irrigation of open fractures. Experimental studies have shown effective removal of bacteria and contamination, but with a potential risk of tissue injury or displacement of contamination deeper into the soft tissues. Rigorous clinical documentation has not validated the optimum flow or pressure characteristics of pressure lavage in clinical practice. There is need for randomized clinical trials to validate pressure lavage in the prevention of infections in soft tissue injuries or high-risk surgical incisions.

  11. Single transverse extended incision for radical neck dissection

    Directory of Open Access Journals (Sweden)

    José Francisco Sales Chagas

    Full Text Available ABSTRACT Objective: to assess the efficacy of the single transverse extended cervical incision in radical neck dissection. Method: we conducted a prospective study, from January 2008 to January 2009, with 18 patients undergoing surgical treatment of malignant tumors of the upper aero-digestive tract. The primary lesion was located in the oral cavity in eight cases, in the oropharynx in three, in the hypopharynx in three, in the larynx in two, in the maxillary sinus, and in one case, the primary injury was hidden. There were 29 neck dissections, eight bilateral and 10 unilateral (26 radical and three selective. Staging revealed nine patients with T4 tumor, one T3, six T2, one T1 and one Tx. Five patients were N0, nine N2b, one N2c and three N3. The average number of dissected lymph nodes was 34.25. We performed the neck dissection through a single incision located in the middle neck, coincident with the skinfold, with a length of about 2 to 3 cm behind the anterior edge of the trapezius muscle and 3 to 4 cm from the midline for the unilateral neck dissections. Results: as complications, there were myocutaneous flap necrosis in one patient with prior radiation therapy, one lymphatic fistula, one dehiscence of the tracheostomy, one cervical abscess, one salivary fistula and one suture dehiscence. Conclusions: the single extended incision provides adequate exposure of the neck structures, without compromising surgical time, even in bilateral dissections. It does not compromise the resection of all cervical lymph nodes; it has excellent aesthetic and functional results and is easily associated with other approaches to resection of the primary tumor.

  12. Signatures of Late Pleistocene fluvial incision in an Alpine landscape

    Science.gov (United States)

    Leith, Kerry; Fox, Matthew; Moore, Jeffrey R.

    2018-02-01

    Uncertainty regarding the relative efficacy of fluvial and glacial erosion has hindered attempts to quantitatively analyse the Pleistocene evolution of alpine landscapes. Here we show that the morphology of major tributaries of the Rhone River, Switzerland, is consistent with that predicted for a landscape shaped primarily by multiple phases of fluvial incision following a period of intense glacial erosion after the mid-Pleistocene transition (∼0.7 Ma). This is despite major ice sheets reoccupying the region during cold intervals since the mid-Pleistocene. We use high-resolution LiDAR data to identify a series of convex reaches within the long-profiles of 18 tributary channels. We propose these reaches represent knickpoints, which developed as regional uplift raised tributary bedrock channels above the local fluvial baselevel during glacial intervals, and migrated upstream as the fluvial system was re-established during interglacial periods. Using a combination of integral long-profile analysis and stream-power modelling, we find that the locations of ∼80% of knickpoints in our study region are consistent with that predicted for a fluvial origin, while the mean residual error over ∼100 km of modelled channels is just 26.3 m. Breaks in cross-valley profiles project toward the elevation of former end-of-interglacial channel elevations, supporting our model results. Calculated long-term uplift rates are within ∼15% of present-day measurements, while modelled rates of bedrock incision range from ∼1 mm/yr for low gradient reaches between knickpoints to ∼6-10 mm/yr close to retreating knickpoints, typical of observed rates in alpine settings. Together, our results reveal approximately 800 m of regional uplift, river incision, and hillslope erosion in the lower half of each tributary catchment since 0.7 Ma.

  13. DNA Mismatch Repair

    Science.gov (United States)

    MARINUS, M. G.

    2014-01-01

    DNA mismatch repair functions to correct replication errors in newly synthesized DNA and to prevent recombination between related, but not identical (homeologous), DNA sequences. The mechanism of mismatch repair is best understood in Escherichia coli and is the main focus of this review. The early genetic studies of mismatch repair are described as a basis for the subsequent biochemical characterization of the system. The effects of mismatch repair on homologous and homeologous recombination are described. The relationship of mismatch repair to cell toxicity induced by various drugs is included. The VSP (Very Short Patch) repair system is described in detail. PMID:26442827

  14. Avoiding thermal injury during near-infrared photoimmunotherapy (NIR-PIT): the importance of NIR light power density.

    Science.gov (United States)

    Okuyama, Shuhei; Nagaya, Tadanobu; Ogata, Fusa; Maruoka, Yasuhiro; Sato, Kazuhide; Nakamura, Yuko; Choyke, Peter L; Kobayashi, Hisataka

    2017-12-22

    Near-infrared photoimmunotherapy (NIR-PIT) is a newly-established cancer treatment which employs the combination of an antibody-photoabsorber conjugate (APC) and NIR light. When NIR light is absorbed by APC-bound tissues, a certain amount of heat is generated locally. For the most part this results in a subclinical rise in skin temperature, however, excessive light exposure may cause non-specific thermal damage. In this study, we investigated the potential for thermal damage caused by NIR-PIT by measuring surface temperature. Two sources of light, laser and light emitting diode (LED), were compared in a mouse tumor model. First, we found that the skin was heated rapidly by NIR light regardless of whether laser or LED light sources were used. Air cooling at the surface reduced the rise in temperature. There were no associations between the rise of skin temperature and tumor volume of the treated tumor, or APC concentration. Second, we investigated the extent of thermal damage to the skin at various light doses. We detected burn injuries 1 day after NIR-PIT, when the NIR light was at a power density higher than 600 mW/cm 2 . Successful treatments at lower power density could be achieved if the total light energy absorbed by the tumor was the same, i.e. by extending the duration of light exposure. In conclusion, this study demonstrates that thermal injury after NIR-PIT can be avoided by either employing a cooling system or by lowering the power density of the light source and prolonging the exposure time such that the total energy is constant. Thus, thermal damage is preventable side effect of NIR-PIT.

  15. The extended minimal incision approach to midface rejuvenation.

    Science.gov (United States)

    Pontius, Allison T; Williams, Edwin F

    2005-08-01

    Recent major advancements in comprehensive facial rejuvenation have focused on management of midfacial aging. Multiple techniques have been described to treat the aging midface; the mere nature of so many approaches is evidence that no one technique has prevailed. Although the nasolabial region remains a challenge to correct, the approach described herein provides comprehensive rejuvenation of the midface, lateral brow, and jawline. The technique is performed via a minimal incision brow-lift approach and has been performed (with minor modifications) by the senior author in more than 650 patients over the past 9 years. The technique has proven to be safe, reliable, and effective.

  16. A case of endophthalmitis associated with limbal relaxing incision

    Directory of Open Access Journals (Sweden)

    Aravind Haripriya

    2012-01-01

    Full Text Available Limbal relaxing incisions (LRIs are considered a relatively safe procedure with rapid stabilization and absence of infectious complications. Do we need to readdress this last impression? We report a case of nocardia endophthalmitis associated with an exudate at the site of an LRI in a patient who underwent routine cataract surgery. This case, to the best of our knowledge, is the first report of its kind, stressing the need for a cautious approach to the adoption of this method of astigmatic correction.

  17. [Preliminary clinical experience of single incision laparoscopic colorectal surgery].

    Science.gov (United States)

    Wu, S D; Han, J Y

    2016-06-01

    Objective: To discuss the preliminary experience of single incision laparoscopic colorectal surgery. Methods: The clinical data and surgical outcomes of 104 selected patients who underwent single incision laparoscopic colorectal surgery in the 2 nd Department of General Surgery, Shengjing Hospital of China Medical University from January 2010 to September 2015 were retrospectively analyzed. There were 62 male and 42 female patients, aging from 21 to 87 years with a mean of (61±12) years. Eighty-five patients were diagnosed with malignancy while the rest 19 cases were benign diseases. All the procedures were performed by the same surgeon using the rigid laparoscopic instruments. Surgical and oncological outcomes were analyzed in 4 kinds of procedures which are over 5 cases respectively, including low anterior resection, abdominoperineal resection, radical right colon resection and radical sigmoidectomy. Results: Single incision laparoscopic colorectal surgery was performed in 104 selected patients and was successfully managed in 99 cases with a total conversion rate of 4.8%. Radical procedures for malignancy in cases with the number of patients more than 5 were performed for 74 cases. For low anterior resection, 35 cases with an average surgical time of (191±57) minutes, average estimated blood loss of (117±72) ml and average number of harvested lymph nodes of 14.6±1.1. For abdominoperineal resection, 9 cases with an average surgical time of (226±54) minutes, average estimated blood loss of (194±95) ml and average number of harvested lymph nodes of 14.1±1.5. For radical right colon resection, 16 cases with an average surgical time of (222±62) minutes, average estimated blood loss of (142±68) ml and average number of harvested lymph nodes of 15.4±2.4. For radical sigmoidectomy, 14 cases with an average surgical time of (159±32) minutes, average estimated blood loss of (94±33) ml and average number of harvested lymph nodes of 13.9±1.5. The overall

  18. Meniscal repair using large diameter horizontal sutures increases fixation strength: an in vitro study.

    Science.gov (United States)

    Kocabey, Yavuz; Taşer, Omer; Hapa, Onur; Güçlü, Aycan; Bozdag, Ergun; Sünbüloglu, Emin; Doral, Mahmutnedim

    2011-02-01

    the purpose of this study was to compare the mechanical characteristics of meniscal repair fixation using horizontal sutures and two different diameter sutures under submaximal cyclic and load to failure test conditions. a 2-cm long anteroposterior vertical longitudinal incision was created in two groups of bovine medial menisci. Lesions were repaired using either #2-0 (Group 1), or #2 (Group 2) Fiberwire suture. Following repair, the lesion was extended through the posterior and anterior meniscal horns so that no tissue secured the repair site. Specimens underwent submaximal cyclic (5-50 N at 1 Hz for 500 cycles) and load to failure testing (5 mm/min crosshead speed) in a servo hydraulic device. Specimen failure mode was verified by the primary investigator. An alpha level of P meniscal tissue. Larger diameter suture provided superior mechanical meniscal fixation. if horizontal suture would be used in meniscal repair, the most suitable larger diameter suture should be used.

  19. Laparoscopic repair for vesicouterine fistulae

    Directory of Open Access Journals (Sweden)

    Rafael A. Maioli

    2015-10-01

    Full Text Available ABSTRACT Objective: The purpose of this video is to present the laparoscopic repair of a VUF in a 42-year-old woman, with gross hematuria, in the immediate postoperative phase following a cesarean delivery. The obstetric team implemented conservative management, including Foley catheter insertion, for 2 weeks. She subsequently developed intermittent hematuria and cystitis. The urology team was consulted 15 days after cesarean delivery. Cystoscopy indicated an ulcerated lesion in the bladder dome of approximately 1.0cm in size. Hysterosalpingography and a pelvic computed tomography scan indicated a fistula. Materials and Methods: Laparoscopic repair was performed 30 days after the cesarean delivery. The patient was placed in the lithotomy position while also in an extreme Trendelenburg position. Pneumoperitoneum was established using a Veress needle in the midline infra-umbilical region, and a primary 11-mm port was inserted. Another 11-mm port was inserted exactly between the left superior iliac spine and the umbilicus. Two other 5-mm ports were established under laparoscopic guidance in the iliac fossa on both sides. The omental adhesions in the pelvis were carefully released and the peritoneum between the bladder and uterus was incised via cautery. Limited cystotomy was performed, and the specific sites of the fistula and the ureteral meatus were identified; thereafter, the posterior bladder wall was adequately mobilized away from the uterus. The uterine rent was then closed using single 3/0Vicryl sutures and two-layer watertight closure of the urinary bladder was achieved by using 3/0Vicryl sutures. An omental flap was mobilized and inserted between the uterus and the urinary bladder, and was fixed using two 3/0Vicryl sutures, followed by tube drain insertion. Results: The operative time was 140 min, whereas the blood loss was 100ml. The patient was discharged 3 days after surgery, and the catheter was removed 12 days after surgery

  20. HARDERSEN IRTF ASTEROID NIR REFLECTANCE SPECTRA V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset includes average near-infrared (NIR) reflectance spectra for 68 main-belt asteroids that were observed at the NASA Infrared Telescope Facility (IRTF),...

  1. Identification of transgenic foods using NIR spectroscopy: A review

    Science.gov (United States)

    Alishahi, A.; Farahmand, H.; Prieto, N.; Cozzolino, D.

    2010-01-01

    The utilization of chemometric methods in the quantitative and qualitative analysis of feeds, foods, medicine and so on has been accompanied with the great evolution in the progress and in the near infrared spectroscopy (NIRS). Hence, recently the application of NIR spectroscopy has extended on the context of genetics and transgenic products. The aim of this review was to investigate the application of NIR spectroscopy to identificate transgenic products and to compare it with the traditional methods. The results of copious researches showed that the application of NIRS technology was successful to distinguish transgenic foods and it has advantages such as fast, avoiding time-consuming, non-destructive and low cost in relation to the antecedent methods such as PCR and ELISA.

  2. HAYABUSA NIRS RAW SPECTRA V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set includes the 117,937 raw spectra returned by the Near-Infrared Spectrometer (NIRS) of the Hayabusa mission. The targets include the asteroid 25143...

  3. NIRS Characterization of Paper Pulps to Predict Kappa Number

    Directory of Open Access Journals (Sweden)

    Ana Moral

    2015-01-01

    Full Text Available Rice is one of the most abundant food crops in the world and its straw stands as an important source of fibres both from an economic and an environmental point of view. Pulp characterization is of special relevance in works involving alternative raw materials, since pulp properties are closely linked to the quality of the final product. One of the analytical techniques that can be used in pulp characterization is near-infrared spectroscopy (NIRS. The use of NIRS has economic and technical advantages over conventional techniques. This paper aims to discuss the convenience of using NIRS to predict Kappa number in rice straw pulps produced under different conditions. We found that the resulting Kappa number can be acceptably estimated by NIRS, as the errors obtained with that method are similar to those found for other techniques.

  4. Toward Adaptation of fNIRS Instrumentation to Airborne Environments

    Science.gov (United States)

    Adamovsky, Grigory; Mackey, Jeffrey; Harrivel, Angela; Hearn, Tristan; Floyd, Bertram

    2014-01-01

    The paper reviews potential applications of functional Near-Infrared Spectroscopy (fNIRS), a well-known medical diagnostic technique, to monitoring the cognitive state of pilots with a focus on identifying ways to adopt this technique to airborne environments. We also discuss various fNIRS techniques and the direction of technology maturation of associated hardware in view of their potential for miniaturization, maximization of data collection capabilities, and user friendliness.

  5. Preliminary study of muscle contraction assessment by NIR spectroscopy

    Science.gov (United States)

    Gelmetti, Andrea; Giardini, Mario E.; Lago, Paolo; Pavesi, Roberta; Zambarbieri, Daniela; Maestri, R.; Felicetti, G.

    1998-01-01

    NIR spectroscopy allows monitoring of muscle oxygenation and perfusion during contraction. The knowledge of modifications of blood characteristics in body tissues has relevant clinical interest. A compact and reliable device, which makes use of two laser diodes at 750 and 810 nm coupled with the skin surface through optical fibers, was tested. NIR and surface EMG signals during isokinetic contractions were studied. A set of parameters was analyzed in order to obtain information about metabolic modifications during muscle fatigue.

  6. Concurrent MR-NIR Imaging for Breast Cancer Diagnosis

    Science.gov (United States)

    2008-06-01

    fibroadenoma , which corresponds to a mass estimated to be 1–2 cm in diameter within a breast of 9 cm diameter located at 6–7 o’clock. Second case (case 2) is...AD_________________ Award Number: W81XWH-04-1-0559 TITLE: Concurrent MR-NIR Imaging for Breast ...CONTRACT NUMBER Concurrent MR-NIR Imaging for Breast Cancer Diagnosis 5b. GRANT NUMBER W81XWH-04-1-0559 5c. PROGRAM ELEMENT NUMBER 6

  7. Compensation techniques in NIRS proton beam radiotherapy

    International Nuclear Information System (INIS)

    Akanuma, A.; Majima, H.; Furukawa, S.

    1982-01-01

    Proton beam has the dose distribution advantage in radiation therapy, although it has little advantage in biological effects. One of the best advantages is its sharp fall off of dose after the peak. With proton beam, therefore, the dose can be given just to cover a target volume and potentially no dose is delivered thereafter in the beam direction. To utilize this advantage, bolus techniques in conjunction with CT scanning are employed in NIRS proton beam radiation therapy planning. A patient receives CT scanning first so that the target volume can be clearly marked and the radiation direction and fixation method can be determined. At the same time bolus dimensions are calculated. The bolus frames are made with dental paraffin sheets according to the dimensions. The paraffin frame is replaced with dental resin. Alginate (a dental impression material with favorable physical density and skin surface contact) is now employed for the bolus material. With fixation device and bolus on, which are constructed individually, the patient receives CT scanning again prior to a proton beam treatment in order to prove the devices are suitable. Alginate has to be poured into the frame right before each treatments. Further investigations are required to find better bolus materials and easier construction methods

  8. Compensation techniques in NIRS proton beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Akanuma, A. (Univ. of Tokyo, Japan); Majima, H.; Furukawa, S.

    1982-09-01

    Proton beam has the dose distribution advantage in radiation therapy, although it has little advantage in biological effects. One of the best advantages is its sharp fall off of dose after the peak. With proton beam, therefore, the dose can be given just to cover a target volume and potentially no dose is delivered thereafter in the beam direction. To utilize this advantage, bolus techniques in conjunction with CT scanning are employed in NIRS proton beam radiation therapy planning. A patient receives CT scanning first so that the target volume can be clearly marked and the radiation direction and fixation method can be determined. At the same time bolus dimensions are calculated. The bolus frames are made with dental paraffin sheets according to the dimensions. The paraffin frame is replaced with dental resin. Alginate (a dental impression material with favorable physical density and skin surface contact) is now employed for the bolus material. With fixation device and bolus on, which are constructed individually, the patient receives CT scanning again prior to a proton beam treatment in order to prove the devices are suitable. Alginate has to be poured into the frame right before each treatments. Further investigations are required to find better bolus materials and easier construction methods.

  9. SHARK-NIR system design analysis overview

    Science.gov (United States)

    Viotto, Valentina; Farinato, Jacopo; Greggio, Davide; Vassallo, Daniele; Carolo, Elena; Baruffolo, Andrea; Bergomi, Maria; Carlotti, Alexis; De Pascale, Marco; D'Orazi, Valentina; Fantinel, Daniela; Magrin, Demetrio; Marafatto, Luca; Mohr, Lars; Ragazzoni, Roberto; Salasnich, Bernardo; Verinaud, Christophe

    2016-08-01

    In this paper, we present an overview of the System Design Analysis carried on for SHARK-NIR, the coronagraphic camera designed to take advantage of the outstanding performance that can be obtained with the FLAO facility at the LBT, in the near infrared regime. Born as a fast-track project, the system now foresees both coronagraphic direct imaging and spectroscopic observing mode, together with a first order wavefront correction tool. The analysis we here report includes several trade-offs for the selection of the baseline design, in terms of optical and mechanical engineering, and the choice of the coronagraphic techniques to be implemented, to satisfy both the main scientific drivers and the technical requirements set at the level of the telescope. Further care has been taken on the possible exploitation of the synergy with other LBT instrumentation, like LBTI. A set of system specifications is then flown down from the upper level requirements to finally ensure the fulfillment of the science drivers. The preliminary performance budgets are presented, both in terms of the main optical planes stability and of the image quality, including the contributions of the main error sources in different observing modes.

  10. Hypospadias repair - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000158.htm Hypospadias repair - discharge To use the sharing features on this page, please enable JavaScript. Your child had hypospadias repair to fix a birth defect in which ...

  11. Anterior vaginal wall repair

    Science.gov (United States)

    ... may have you: Learn pelvic floor muscle exercises ( Kegel exercises ) Use estrogen cream in your vagina Try ... repair; Urinary incontinence - vaginal wall repair Patient Instructions Kegel exercises - self-care Self catheterization - female Suprapubic catheter ...

  12. Retinal detachment repair

    Science.gov (United States)

    ... area (the macula). This can help prevent further detachment of the retina. It also will increase the chance of preserving ... buckling; Vitrectomy; Pneumatic retinopexy; Laser retinopexy; Rhegmatogenous retinal detachment repair Images ... detachment repair - series References Connolly BP, Regillo ...

  13. Collision Repair Campaign

    Science.gov (United States)

    The Collision Repair Campaign targets meaningful risk reduction in the Collision Repair source category to reduce air toxic emissions in their communities. The Campaign also helps shops to work towards early compliance with the Auto Body Rule.

  14. Single Incision Laparoscopic Cholecystectomy vs Conventional Cholecystectomy in Developing Country

    Directory of Open Access Journals (Sweden)

    P B Thapa

    2010-09-01

    Full Text Available INTRODUCTION: Use of laparoscopic surgery has demanded principles of less trauma of access hence less scar and so probably less complications. Hence conventional laparoscopic surgeries were tried with natural orifice transluminal surgery (NOTES and then single incision laparoscopic surgery (SILS. With refinement in instruments and surgeons skills SILS have bridged up between conventional and NOTES in order to quench the desire of less or no scar at all. METHODS: Comparative case control study between conventional laparoscopic cholecystectomy and SILS in public teaching hospital. RESULTS: Total 20 patients underwent SILS cholecystectomy and 20 underwent conventional cholecystectomy and found that no difference between both in terms of post operative pain score, hospital stay and post operative wound infection except significant difference in mean operative time and patient's level of satisfaction was less in patient with SILC if were subjected to pay for instruments in order to maintain cosmesis. CONCLUSIONS: Though SILS have gained rapid acceptance in surgical fraternity, large number of randomized controlled trials are necessary to show its benefit over conventional laparoscopic cholecystectomy. Keywords: cholecystectomy, conventional, laparoscopy, single incision, surgery

  15. Single-incision laparoscopic surgery for diverticulitis in overweight patients.

    Science.gov (United States)

    Rink, Andreas D; Vestweber, Boris; Hahn, Jasmina; Alfes, Angelika; Paul, Claudia; Vestweber, Karl-Heinz

    2015-10-01

    Single-incision laparoscopic surgery (SILS) has been introduced as a new technique for the treatment of various colorectal diseases. Recurrent or complicated diverticulitis of the sigmoid colon is a frequent indication for minimally invasive sigmoid colectomy. The aim of this study was to investigate the impact of obesity on the outcome of SILS sigmoid colectomy. From September 2009 to October 2014, data from 377 patients who had intended SILS sigmoid colectomy for diverticulitis at our institution were collected in a prospective database. The patients were categorized in the following subgroups: group 1 (normal weight, body mass index (BMI)  35 kg/m(2)). The groups were equivalent for sex, age, status of diverticulitis, the presence of acute inflammation in the specimen, and the percentage of teaching operations, but the percentage of patients with accompanying diseases was significantly more frequent in groups 2, 3, and 4 (p = 0.04, 0.008, and 0.018, respectively). As compared to group 1, the conversion rate was significantly increased in groups 2 and 4 (2.3 vs. 9.3% (p = 0.013) and 2.3 vs. 12.5% (p = 0.017), respectively). The duration of surgery, hospitalization, and morbidity did not differ between the four groups. Up to a body mass index of 35 kg/m(2), increased body weight does not significantly reduce the feasibility and outcome of single-incision laparoscopic surgery for diverticulitis.

  16. Muscle sparing lateral thoracotomy: the standard incision for thoracic procedures

    Directory of Open Access Journals (Sweden)

    Mihai Dumitrescu

    2017-05-01

    Full Text Available Lateral thoracotomy is a versatile approach with many variations and is currently the most widely used incision in thoracic surgery. In the current article we are presenting the muscle-sparing lateral thoracotomy in the lateral decubitus position which we consider to be the “standard” for lateral thoracotomies. Indications, surgical technique and pitfalls are described alongside our experience with thoracic drainage. Although there is no consensus regarding the name of this incision, some authors call it “axillary thoracotomy” while others call it a “modified lateral thoracotomy”, they all agree on one aspect – the importance of muscle sparing – which makes it the go-to thoracotomy for both small and large procedures involving the lung. Lateral muscle sparing thoracotomy allows for good exposure of the pulmonary hilum, fissures, apex and diaphragm. The approach is easy and quick to perform while at the same time ensuring faster postoperative recovery by sparing the latissimus dorsi muscle, better cosmetics and lower postoperative pain score when compared to the posterolateral or classical lateral thoracotomies.

  17. Unilateral corneal ectasia following small-incision lenticule extraction.

    Science.gov (United States)

    Sachdev, Gitansha; Sachdev, Mahipal S; Sachdev, Ritika; Gupta, Hemlata

    2015-09-01

    We describe a case of unilateral corneal ectasia in a 26-year-old man following small-incision lenticule extraction. The preoperative corneal topography was normal, with a minimum corneal thickness of 511 μm and 513 μm in the right eye and left eye, respectively. Lenticules of 85 μm and 82 μm were fashioned to offer a refractive correction of -3.75 -1.50 × 180 and -3.50 -1.50 × 165 in the right eye and left eye, respectively. Twelve months after small-incision lenticule extraction, the patient presented with early signs of ectasia in the left eye on corneal topography, which had worsened at the 18-month examination. Intrastromal corneal ring segment implantation with corneal collagen crosslinking was performed to arrest further progression and to improve uncorrected distance visual acuity. On the last examination, the corrected distance visual acuity was 20/20(-2). Dr. Mahipal S. Sachdev receives travel grants from Carl Zeiss Meditec AG. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Endoscopy-assisted cerebral falx incision via unilateral

    Directory of Open Access Journals (Sweden)

    DONG Ji-rong

    2012-04-01

    Full Text Available 【Abstract】Objective: To investigate the clinical features and treatment strategy of dissymmetric bilateral frontal contusion, and to summarize our experience in treat-ing these patients by minimally invasive surgery. Methods: Over the past 3 years, we have treated a total of 31 patients with dissymmetric bilateral frontal contusion using endoscopy-assisted unilateral cerebral falx incision. Other 30 patients treated by routine bilateral approaches within the same period were taken as control. Results: Seventeen cases (54.8% in the unilateral operation group survived and were in good condition, 8 (25.8% had moderate disability, 4 (12.9% had severe disability, 1 (3.2% was in vegetative state, and 1 (3.2% died. Compared with the control group, the Glasgow Out-come Scale score was not significantly different in the uni-lateral operation group, but the operation time, blood trans-fusion volume, the length of hospital stay, the incidences of mental disorder and olfactory nerve injury were greatly reduced in the unilateral operation group. Conclusions: Endoscopy-assisted unilateral cerebral falx incision can shorten the operation time, reduce surgical trauma and complications in treatment of patients with dis-symmetric bilateral frontal contusion. It can obviously di-minish the chance of delayed intracerebral hematoma and subsequently minimize the incidences of subfalcial and centrencephalic herniation. Key words: Brain injuries; Intracranial hemorrage, traumatic; Endoscopy; Surgically procedures, minimally invasive

  19. Single incision laparoscopic liver resection (SILL – a systematic review

    Directory of Open Access Journals (Sweden)

    Benzing, Christian

    2015-12-01

    Full Text Available Background: Today, minimally invasive liver resections for both benign and malignant tumors are routinely performed. Recently, some authors have described single incision laparoscopic liver resection (SILL procedures. Since SILL is a relatively young branch of laparoscopy, we performed a systematic review of the current literature to collect data on feasibility, perioperative results and oncological outcome.Methods: A literature research was performed on Medline for all studies that met the eligibility criteria. Titles and abstracts were screened by two authors independently. A study was included for review if consensus was obtained by discussion between the authors on the basis of predefined inclusion criteria. A thorough quality assessment of all included studies was performed. Data were analyzed and tabulated according to predefined outcome measures. Synthesis of the results was achieved by narrative review. Results: A total of 15 eligible studies were identified among which there was one prospective cohort study and one randomized controlled trial comparing SILL to multi incision laparoscopic liver resection (MILL. The rest were retrospective case series with a maximum of 24 patients. All studies demonstrated convincing results with regards to feasibility, morbidity and mortality. The rate of wound complications and incisional hernia was low. The cosmetic results were good.Conclusions: This is the first systematic review on SILL including prospective trials. The results of the existing studies reporting on SILL are favorable. However, a large body of scientific evidence on the field of SILL is missing, further randomized controlled studies are urgently needed.

  20. Magnetic resonance imaging evaluation of incision healing after cesarean sections

    International Nuclear Information System (INIS)

    Dicle, O.; Kuecuekler, C.; Pirnar, T.; Erata, Y.; Posaci, C.

    1997-01-01

    The purpose of this study was to examine the healing period of incision scar in myometrial wall and the normal pelvis after cesarean sections by means of MRI. In this study 17 voluntary women were examined after their first delivery with cesarean section in the early postpartum period (first 5 days), and following this, three more times in 3-month intervals. The MRI examinations were performed on a 1.0-T system (Magnetom, Siemens, Erlangen, Germany), and sagittal T1-weighted (550/17 TR/TE) and T2-weighted (2000/80 TR/TE) spin-echo (SE) images of the pelvis were obtained. During follow-up examinations incision scar tissues lost their signals within the first 3 months on both SE sequences, and little alteration was observed in the subsequent tests. Zonal anatomy of the uterus reappeared completely 6 months after cesarean sections. The time for the involution of the uterus was independent of the zonal anatomy recovery, and the maximum involution was inspected within the first 3 months. In conclusion, the maturation time of myometrial scar tissue in uncomplicated cesarean sections, which can be evaluated by the signal alterations in MRI, is approximately 3 months, whereas the complete involution and the recovery of the zonal anatomy need at least 6 months. (orig.). With 6 figs

  1. Magnetic resonance imaging evaluation of incision healing after cesarean sections

    Energy Technology Data Exchange (ETDEWEB)

    Dicle, O. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Kuecuekler, C. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Pirnar, T. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Erata, Y. [Department of Gynecology and Obstetrics, Dokuz Eyluel University, Izmir (Turkey); Posaci, C. [Department of Gynecology and Obstetrics, Dokuz Eyluel University, Izmir (Turkey)

    1997-02-01

    The purpose of this study was to examine the healing period of incision scar in myometrial wall and the normal pelvis after cesarean sections by means of MRI. In this study 17 voluntary women were examined after their first delivery with cesarean section in the early postpartum period (first 5 days), and following this, three more times in 3-month intervals. The MRI examinations were performed on a 1.0-T system (Magnetom, Siemens, Erlangen, Germany), and sagittal T1-weighted (550/17 TR/TE) and T2-weighted (2000/80 TR/TE) spin-echo (SE) images of the pelvis were obtained. During follow-up examinations incision scar tissues lost their signals within the first 3 months on both SE sequences, and little alteration was observed in the subsequent tests. Zonal anatomy of the uterus reappeared completely 6 months after cesarean sections. The time for the involution of the uterus was independent of the zonal anatomy recovery, and the maximum involution was inspected within the first 3 months. In conclusion, the maturation time of myometrial scar tissue in uncomplicated cesarean sections, which can be evaluated by the signal alterations in MRI, is approximately 3 months, whereas the complete involution and the recovery of the zonal anatomy need at least 6 months. (orig.). With 6 figs.

  2. Novel INHAT repressor (NIR) is required for early lymphocyte development.

    Science.gov (United States)

    Ma, Chi A; Pusso, Antonia; Wu, Liming; Zhao, Yongge; Hoffmann, Victoria; Notarangelo, Luigi D; Fowlkes, B J; Jain, Ashish

    2014-09-23

    Novel inhibitor of histone acetyltransferase repressor (NIR) is a transcriptional corepressor with inhibitor of histone acetyltransferase activity and is a potent suppressor of p53. Although NIR deficiency in mice leads to early embryonic lethality, lymphoid-restricted deletion resulted in the absence of double-positive CD4(+)CD8(+) thymocytes, whereas bone-marrow-derived B cells were arrested at the B220(+)CD19(-) pro-B-cell stage. V(D)J recombination was preserved in NIR-deficient DN3 double-negative thymocytes, suggesting that NIR does not affect p53 function in response to physiologic DNA breaks. Nevertheless, the combined deficiency of NIR and p53 provided rescue of DN3L double-negative thymocytes and their further differentiation to double- and single-positive thymocytes, whereas B cells in the marrow further developed to the B220(+)CD19(+) pro-B-cell stage. Our results show that NIR cooperate with p53 to impose checkpoint for the generation of mature B and T lymphocytes.

  3. Convolutional Sparse Coding for RGB+NIR Imaging.

    Science.gov (United States)

    Hu, Xuemei; Heide, Felix; Dai, Qionghai; Wetzstein, Gordon

    2018-04-01

    Emerging sensor designs increasingly rely on novel color filter arrays (CFAs) to sample the incident spectrum in unconventional ways. In particular, capturing a near-infrared (NIR) channel along with conventional RGB color is an exciting new imaging modality. RGB+NIR sensing has broad applications in computational photography, such as low-light denoising, it has applications in computer vision, such as facial recognition and tracking, and it paves the way toward low-cost single-sensor RGB and depth imaging using structured illumination. However, cost-effective commercial CFAs suffer from severe spectral cross talk. This cross talk represents a major challenge in high-quality RGB+NIR imaging, rendering existing spatially multiplexed sensor designs impractical. In this work, we introduce a new approach to RGB+NIR image reconstruction using learned convolutional sparse priors. We demonstrate high-quality color and NIR imaging for challenging scenes, even including high-frequency structured NIR illumination. The effectiveness of the proposed method is validated on a large data set of experimental captures, and simulated benchmark results which demonstrate that this work achieves unprecedented reconstruction quality.

  4. Epoch making NIRS studies seen through citation trends

    International Nuclear Information System (INIS)

    Dan, Ippeita

    2009-01-01

    Near-infrared spectroscopy (NIRS) studies through citation trends are investigated of literature concerning only the brain function measurement and its methodology together with NIRS principle, technological development, present state and future view. Investigation is conducted firstly for the survey of important author name of those concerned papers in Web of Science and Google Scholar with search words of NIRS, brain and optical topography as an option. Second, >100 papers of those authors citing any of them are picked up and their papers are ranked in accordance with Web of Science citation number, of which top-nineteen are presented here. Impact and epoch making papers are reviewed with explanations of: the establishment of measuring technology of cerebral blood flow change and subsequent brain function by NIRS; development with multi-channel detection; simultaneous measurement with other imaging modalities; examination of NIRS validity; spatial analysis of NIRS; and measurement of brain function. The highest times of citation are 1,238 of the paper by F. F. Jobsis in 'Science' (1977). It should be noted that 10 of top 19 papers are those by Japanese authors. However, review articles omitted in the present literature survey are mostly described by foreign authors: an effort to systemize the concerned fields might be required in this country. (K.T.)

  5. Influence of upper and temporal transconjunctival sclerocorneal incision on marginal reflex distance after cataract surgery

    OpenAIRE

    Tamaki, Rikiya; Gosho, Masahiko; Mizumoto, Kyoichi; Kato, Nahoko; Zako, Masahiro

    2016-01-01

    Background Ptosis incidence following cataract surgery is reduced with a recently developed phacoemulsification technique using a small incision. However, it remains uncertain whether an upper transconjunctival sclerocorneal incision can cause minor blepharoptosis. In the present prospective study, patients underwent cataract surgery with either an upper or temporal 2.4-mm transconjunctival sclerocorneal incision. We measured the marginal reflex distance 1 (MRD1) preoperatively and postoperat...

  6. Autogenic entrenchment patterns and terraces due to coupling with lateral erosion in incising alluvial channels

    Science.gov (United States)

    Malatesta, Luca C.; Prancevic, Jeffrey P.; Avouac, Jean-Philippe

    2017-01-01

    The abandonment of terraces in incising alluvial rivers can be used to infer tectonic and climatic histories. A river incising into alluvium erodes both vertically and laterally as it abandons fill-cut terraces. We argue that the input of sediment from the valley walls during entrenchment can alter the incision dynamics of a stream by promoting vertical incision over lateral erosion. Using a numerical model, we investigate how valley wall feedbacks may affect incision rates and terrace abandonment as the channel becomes progressively more entrenched in its valley. We postulate that erosion of taller valley walls delivers large pulses of sediment to the incising channel, potentially overwhelming the local sediment transport capacity. Based on field observations, we propose that these pulses of sediment can form talus piles that shield the valley wall from subsequent erosion and potentially force progressive channel narrowing. Our model shows that this positive feedback mechanism can enhance vertical incision relative to 1-D predictions that ignore lateral erosion. We find that incision is most significantly enhanced when sediment transport rates are low relative to the typical volume of material collapsed from the valley walls. The model also shows a systematic erosion of the youngest terraces when river incision slows down. The autogenic entrenchment due to lateral feedbacks with valley walls should be taken into account in the interpretation of complex-response terraces.

  7. Safety of cesarean delivery through placental incision in patients with anterior placenta previa.

    Science.gov (United States)

    Hong, Deok-Ho; Kim, Eugene; Kyeong, Kyu-Sang; Hong, Seung Hwa; Jeong, Eun-Hwan

    2016-03-01

    To demonstrate the safety of fetal delivery through placental incision in a placenta previa pregnancy. We examined the medical records of 80 women with singleton pregnancy diagnosed with placenta previa who underwent cesarean section between May 2010 and May 2015 at the Department of Obstetrics and Gynecology, Chungbuk National University Hospital. Among the women with placenta previa, those who did not have the placenta in the uterine incision site gave birth via conventional uterine incision, while those with anterior placenta previa or had placenta attached to the uterine incision site gave birth via uterine incision plus placental incision. We compared the postoperative hemoglobin level and duration of hospital stay for the mother and newborn of the two groups. There was no difference between the placental incision group and non-incision group in terms of preoperative and postoperative hemoglobin change, the amount of blood transfusions required by the mother, newborns with 1-min or 5-min Apgar scores below 7 points or showing signs of acidosis on umbilical cord blood gas analysis result of pH below 7.20. Moreover, neonatal hemoglobin levels did not differ between the two groups. Fetal delivery through placental incision during cesarean section for placenta previa pregnancy does not negatively influence the prognosis of the mother or the newborn, and therefore, is considered a safe surgical technique.

  8. Aromatic Fused [30] Heteroannulenes with NIR Absorption and NIR Emission: Synthesis, Characterization, and Excited-State Dynamics.

    Science.gov (United States)

    Mallick, Abhijit; Oh, Juwon; Kim, Dongho; Rath, Harapriya

    2016-06-06

    Two hitherto unknown planar aromatic [30] fused heterocyclic macrocycles (1.1.0.1.1.0), with NIR absorption in free-base form and protonation-induced enhanced NIR emission, have been synthesized from easy to make precursors. The induced correspondence of fusion on the macrocyclic structure, electronic absorption, and emission spectra have been highlighted. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Advantages of the modified double ring areolar incision over the traditional areolar incision in multicentric breast fibroadenoma surgery.

    Science.gov (United States)

    Zhang, Mingliang; Shen, Gongjin; Zhang, Song; Cui, Zhen; Qian, Jun

    2017-09-01

    This study was conducted to investigate the clinical advantages of modified double ring areola incision (MDRAI) compared to ordinary areola incision (OAI) in multicentric breast fibroadenoma in women. Sixty cases of multicentric benign breast tumor were recruited from the First Affiliated Hospital of Bengbu Medical College from January to December 2016. The cases were divided into two groups according to surgical approach: MDRAI (n = 20) and OAI (n = 40). The operation duration, intraoperative blood loss, drainage time, and postoperative recurrence rate in the first six months were compared. The mean age and tumor locations were not statistically different between the groups (P > 0.05). However, more lesions and larger tumor diameter were found in the MDRAI group than in the OAI group, with statistical difference (P  0.05). However, the intraoperative blood loss was statistically different between the two groups (P < 0.05). All 60 cases received six months of follow-up. Eight recurrent cases were found in the OAI group, but none in the MDRAI group. The recurrence rate was significantly different (χ 2  = 4.62, P < 0.05). Compared with OAI, MDRAI offers greater advantages in the aspects of blood loss and recurrence for the treatment of breast benign tumor, especially for multicentric larger lesions. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  10. Sensitivity of fNIRS to cognitive state and load

    Directory of Open Access Journals (Sweden)

    Frank Anthony Fishburn

    2014-02-01

    Full Text Available Functional near-infrared spectroscopy (fNIRS is an emerging low-cost noninvasive neuroimaging technique that measures cortical bloodflow. While fNIRS has gained interest as a potential alternative to fMRI for use with clinical and pediatric populations, it remains unclear whether fNIRS has the necessary sensitivity to serve as a replacement for fMRI. The present study set out to examine whether fNIRS has the sensitivity to detect linear changes in activation and functional connectivity in response to cognitive load, and functional connectivity changes when transitioning from a task-free resting state to a task. Sixteen young adult subjects were scanned with a continuous-wave fNIRS system during a 10-minute resting-state scan followed by a letter n-back task with three load conditions. Five optical probes were placed over frontal and parietal cortices, covering bilateral dorsolateral PFC (dlPFC, bilateral ventrolateral PFC (vlPFC, frontopolar cortex (FP, and bilateral parietal cortex. Activation was found to scale linearly with working memory load in bilateral prefrontal cortex. Functional connectivity increased with increasing n-back loads for fronto-parietal, interhemispheric dlPFC, and local connections. Functional connectivity differed between the resting state scan and the n-back scan, with fronto-parietal connectivity greater during the n-back, and interhemispheric vlPFC connectivity greater during rest. These results demonstrate that fNIRS is sensitive to both cognitive load and state, suggesting that fNIRS is well-suited to explore the full complement of neuroimaging research questions and will serve as a viable alternative to fMRI.

  11. Mouse preferential incising force orientation changes during jaw closing muscle hyperalgesia and is sex dependent.

    Science.gov (United States)

    Widmer, C G; Morris-Wiman, J

    2016-12-01

    Mouse incising is controlled by a central pattern generator and this activity can change in the presence of pain. The incising frequency and maximum force generation decreases with pain. In this study, we used repetitive acidic injections in the left masseter muscle of male and female mice to determine differences between baseline and jaw muscle pain conditions and the effect of sex on preferential incising direction. A within subject design was used to evaluate data previously acquired using multi-axis force data (X, Y and Z) from the 4th baseline recording day and day 7 post-injection (day of maximal pain response) for each mouse of each sex. A total of 34 female and male (age 3-9months) CD-1 mice were evaluated. After mathematically rotating the X and Y axes to align the Y axis to be parallel to the wire struts of the cage top, data were analyzed to determine incising direction preference during baseline (non-pain) and pain (day 7) conditions and between sex. Radar plots of X-Y, X-Z and Y-Z axes depicted the average direction of incising preference between baseline and pain conditions for each sex. Statistical differences among groups were tested using a mixed model ANOVA. Similar to previous findings, female mice had a more robust difference in incising direction preference when comparing male and female pain conditions and this was most evident in the X-Z axes. The incising frequencies most commonly affected were 5.3, 6.2 and 7.6Hz. Male mice varied little in their incising direction preference between the baseline and pain conditions. In addition, statistical comparison of ratios of the percent of time spent incising in the Z versus X axes for each incising frequency found that the incising preference was not different when comparing 5.3 and 7.6Hz frequencies. Finally, female mice used a novel approach to minimize pain while incising by rotating their head and body nearly 180 degrees while males did not use this strategy as frequently. The preferred incising

  12. Single-incision laparoscopic splenectomy with innovative gastric traction suture

    Directory of Open Access Journals (Sweden)

    Srikanth G

    2011-01-01

    Full Text Available Laparoscopic splenectomy is now the gold standard for patients with idiopathic thrombocytopenic purpura (ITP undergoing splenectomy. There are a few reports in literature on single-incision laparoscopic (SIL splenectomy. Herein, we describe a patient undergoing SIL splenectomy for ITP without the use of a disposable port device. We report a 20-year-old female patient with steroid-refractory ITP having a platelet count of 14,000/cmm who underwent a SIL splenectomy. Dissection was facilitated by the use of a single articulating grasper and a gastric traction suture and splenic vessels were secured at the hilum with an endo-GIA stapler. She made an uneventful postoperative recovery and was discharged on the second postoperative day. She is doing well with no visible scar at 8-month follow-up.

  13. Median sternotomy - gold standard incision for cardiac surgeons

    Directory of Open Access Journals (Sweden)

    Radu Matache

    2016-05-01

    Full Text Available Sternotomy is the gold standard incision for cardiac surgeons but it is also used in thoracic surgery especially for mediastinal, tracheal and main stem bronchus surgery. The surgical technique is well established and identification of the correct anatomic landmarks, midline tissue preparation, osteotomy and bleeding control are important steps of the procedure. Correct sternal closure is vital for avoiding short- and long-term morbidity and mortality. The two sternal halves have to be well approximated to facilitate healing of the bone and to avoid instability, which is a risk factor for wound infection. New suture materials and techniques would be expected to be developed to further improve the patients evolution, in respect to both immediate postoperative period and long-term morbidity and mortality

  14. A case of bifocal endometriosis involving a pfannenstiel incision.

    Science.gov (United States)

    Evsen, Mehmet Sidik; Sak, Muhammet Erdal; Yalinkaya, Ahmet; Firat, Ugur; Caca, Fatma Nur

    2011-01-01

    A 25-year-old woman was referred to our clinic for atypical cyclic pain and masses at both ends of a Pfannenstiel incision scar. Ultrasound of the anterior abdominal wall showed two masses. Both masses were hypoechoic, heterogeneous lesions located at opposite ends of the scar. The lesions were surgically excised with. Microscopic examination revealed endometrial gland structures with endometrial stroma in fibroadipose tissue in sections of both specimens indicative of endometriosis. Incisional endometriosis (IE) is a form of extrapelvic endometriosis especially in scars of obstetric or gynecologic surgery IE may be multifocal at surgical scars. We report the a case of bifocal incisional endometriosis in Pfannesteil scar. Whole scar evaluation should be done for incisional endometriosis and surgical excision should be performed for treatment.

  15. A 1-D morphodynamic model of postglacial valley incision

    Science.gov (United States)

    Tunnicliffe, Jon F.; Church, Michael

    2015-11-01

    Chilliwack River is typical of many Cordilleran valley river systems that have undergone dramatic Holocene degradation of valley fills that built up over the course of Pleistocene glaciation. Downstream controls on base level, mainly blockage of valleys by glaciers, led to aggradation of significant glaciofluvial and glaciolacustrine valley fills and fan deposits, subsequently incised by fluvial action. Models of such large-scale, long-term degradation present a number of important challenges since the evolution of model parameters, such as the rate of bedload transport and grain size characteristics, are governed by the nature of the deposit. Sediment sampling in the Chilliwack Valley reveals a complex sequence of very coarse to fine textural modes. We present a 1-D numerical morphodynamic model for the river-floodplain system tailored to conditions in the valley. The model is adapted to dynamically adjust channel width to optimize sediment transporting capacity and to integrate relict valley fill material as the channel incises through valley deposits. Sensitivity to model parameters is studied using four principal criteria: profile concavity, rate of downstream grain size fining, bed surface sand content, and the timescale to equilibrium. Model results indicate that rates of abrasion and coarsening of the grain size distributions exert the strongest controls on all of the interrelated model performance criteria. While there are a number of difficulties in satisfying all model criteria simultaneously, results indicate that 1-D models of valley bottom sedimentary systems can provide a suitable framework for integrating results from sediment budget studies and chronologies of sediment evacuation established from dating.

  16. Anastomosis Procedure through an Inguinal Hernia Incision in ...

    African Journals Online (AJOL)

    The bowel resection was performed extracorporeally, and an anvil was placed at the proximal end of the colon over a purse-string suture. After colorectal anastomosis was performed using a circular stapler inserted through the anus, the inguinal hernia was repaired with a mesh. The inguinal wound healed without surgical ...

  17. Combined use of Mathieu and incised plate technique (Snodgrass ...

    African Journals Online (AJOL)

    H.K. Salem

    Snodgrass technique) for repair of distal hypospadias in older children. H.K. Salema, A. Shelbaiaa,∗. , A. Elnasharb a Department of Urology, Kasr Al Ainy Hospital and Student hospital Cairo University, Cairo, Egypt b Department of Urology, ...

  18. Assessment of postoperative outcomes of hypospadias repair with validated questionnaires.

    Science.gov (United States)

    Liu, Mona M Y; Holland, Andrew J A; Cass, Danny T

    2015-12-01

    A standardized assessment for the optimal repair of hypospadias remains elusive. This study utilized validated questionnaires to assess the postoperative functional, cosmetic, and psychosocial outcomes of hypospadias repair. 172 patients who underwent hypospadias repair under the care of a single surgeon were identified. 25 agreed for follow-up using the validated questionnaires of Hypospadias Objective Scoring Evaluation (HOSE), Pediatric Penile Perception Scale (PPPS), and Pediatric Quality of Life Inventory (PedsQL™4.0). Mean follow-up was 59months postoperatively (range 7-113months). Techniques used included tubularized incised plate urethroplasty, meatal advancement and glanuloplasty, and a 2-stage repair. 23 of 25 patients achieved a HOSE score of 14 or more (maximum of 16). The PPPS scores correlated with severity of the hypospadias. Those with glanular hypospadias (mean score=10) scored higher than those with coronal (mean score=9) and penile/penoscrotal hypospadias (mean score=7). There was no correlation between PedsQL™4.0 scores and the severity of hypospadias or procedure used. Validated questionnaires revealed generally good functional, cosmetic, and early psychosocial outcomes after hypospadias repair. The use of validated questionnaires in routine follow-up sessions may facilitate objective assessment of both functional outcomes and patient satisfaction. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. The current state of eukaryotic DNA base damage and repair.

    Science.gov (United States)

    Bauer, Nicholas C; Corbett, Anita H; Doetsch, Paul W

    2015-12-02

    DNA damage is a natural hazard of life. The most common DNA lesions are base, sugar, and single-strand break damage resulting from oxidation, alkylation, deamination, and spontaneous hydrolysis. If left unrepaired, such lesions can become fixed in the genome as permanent mutations. Thus, evolution has led to the creation of several highly conserved, partially redundant pathways to repair or mitigate the effects of DNA base damage. The biochemical mechanisms of these pathways have been well characterized and the impact of this work was recently highlighted by the selection of Tomas Lindahl, Aziz Sancar and Paul Modrich as the recipients of the 2015 Nobel Prize in Chemistry for their seminal work in defining DNA repair pathways. However, how these repair pathways are regulated and interconnected is still being elucidated. This review focuses on the classical base excision repair and strand incision pathways in eukaryotes, considering both Saccharomyces cerevisiae and humans, and extends to some important questions and challenges facing the field of DNA base damage repair. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  20. True Lies: The Double Life of the Nucleotide Excision Repair Factors in Transcription and DNA Repair

    Directory of Open Access Journals (Sweden)

    Nicolas Le May

    2010-01-01

    Full Text Available Nucleotide excision repair (NER is a major DNA repair pathway in eukaryotic cells. NER removes structurally diverse lesions such as pyrimidine dimers, arising upon UV irradiation or bulky chemical adducts, arising upon exposure to carcinogens and some chemotherapeutic drugs. NER defects lead to three genetic disorders that result in predisposition to cancers, accelerated aging, neurological and developmental defects. During NER, more than 30 polypeptides cooperate to recognize, incise, and excise a damaged oligonucleotide from the genomic DNA. Recent papers reveal an additional and unexpected role for the NER factors. In the absence of a genotoxic attack, the promoters of RNA polymerases I- and II-dependent genes recruit XPA, XPC, XPG, and XPF to initiate gene expression. A model that includes the growth arrest and DNA damage 45α protein (Gadd45α and the NER factors, in order to maintain the promoter of active genes under a hypomethylated state, has been proposed but remains controversial. This paper focuses on the double life of the NER factors in DNA repair and transcription and describes the possible roles of these factors in the RNA synthesis process.

  1. Repair of chronic distal biceps brachii tendon rupture using free autogenous semitendinosus tendon.

    Science.gov (United States)

    Hang, D W; Bach, B R; Bojchuk, J

    1996-02-01

    Distal biceps brachii tendon ruptures occur much less frequently than do their proximal counterparts. Distal tendon ruptures usually are associated with considerable function deficits and may require surgical treatment. Repair of chronic distal biceps brachii ruptures are extremely unusual. A free autogenous semitendinosus tendon graft was used to reconstruct the distal biceps tendon by reattaching the graft to the radial tuberosity via a 2-incision technique in a patient with symptoms and a chronic injury.

  2. Meniscal repair by synovial flap transfer. Healing of the avascular zone in rabbits.

    Science.gov (United States)

    Cisa, J; Basora, J; Madarnas, P; Ghibely, A; Navarro-Quilis, A

    1995-02-01

    We studied repair of a longitudinal incision of the right medial meniscus in 44 rabbits after the transfer of a pedunculated synovial flap, without immobilization of the knee. The left medial meniscus was used as the control, after creating the same lesion without synovial flap. Healing was analyzed by histologic studies, including India ink perfusion after 8, 12, 24, and 48 weeks. In three quarters of the cases, the meniscus showed healing with vascularization of an originally avascular zone.

  3. Laser-activated nano-biomaterials for tissue repair and controlled drug release

    Energy Technology Data Exchange (ETDEWEB)

    Matteini, P; Ratto, F; Rossi, F; Pini, R [Institute of Applied Physics ' Nello Carrara' , National Research Council, via Madonna del Piano 10 50019 Sesto Fiorentino (Italy)

    2014-07-31

    We present recent achievements of minimally invasive welding of biological tissue and controlled drug release based on laser-activated nano-biomaterials. In particular, we consider new advancements in the biomedical application of near-IR absorbing gold nano-chromophores as an original solution for the photothermal repair of surgical incisions and as nanotriggers of controlled drug release from hybrid biopolymer scaffolds. (laser biophotonics)

  4. Parotid Duct Repair by Facial Vein Graft versus Gore-Tex, A Sialographic Evaluation

    OpenAIRE

    Gheisari, R; Mohamadinezhad, C; Mehravaran, R; Ziaei, M

    2013-01-01

    Statement of Problem: The most common method for parotid duct anastomosis is suturing. A ductal defect of greater than 1cm may prevent a direct anastomosis. Purpose: The goal of this study was a sialographic evaluation to compare repairing a parotid duct with facial vein graft versus Gore-Tex tub in 19 dogs. Material and Methods: Nineteen dogs were studied in this experimental trial. Extra oral transverse incisions were made in buccal regions bilaterally to expose parotid ducts and a defect (...

  5. Monitoring osteoarthritis progression using near infrared (NIR) spectroscopy.

    Science.gov (United States)

    Afara, Isaac O; Prasadam, Indira; Arabshahi, Zohreh; Xiao, Yin; Oloyede, Adekunle

    2017-09-13

    We demonstrate in this study the potential of near infrared (NIR) spectroscopy as a tool for monitoring progression of cartilage degeneration in an animal model. Osteoarthritic degeneration was artificially induced in one joint in laboratory rats, and the animals were sacrificed at four time points: 1, 2, 4, and 6 weeks (3 animals/week). NIR spectra were acquired from both (injured and intact) knees. Subsequently, the joint samples were subjected to histological evaluation and glycosaminoglycan (GAG) content analysis, to assess disease severity based on the Mankin scoring system and to determine proteoglycan loss, respectively. Multivariate spectral techniques were then employed for classification (principal component analysis and support vector machines) and prediction (partial least squares regression) of the samples' Mankin scores and GAG content from their NIR spectra. Our results demonstrate that NIR spectroscopy is sensitive to degenerative changes in articular cartilage, and is capable of distinguishing between mild (weeks 1&2; Mankin 3) cartilage degeneration. In addition, the spectral data contains information that enables estimation of the tissue's Mankin score (error = 12.6%, R 2  = 86.2%) and GAG content (error = 7.6%, R 2  = 95%). We conclude that NIR spectroscopy is a viable tool for assessing cartilage degeneration post-injury, such as, post-traumatic osteoarthritis.

  6. Multipoint-NIR-measurements in pharmaceutical powder applications

    International Nuclear Information System (INIS)

    Heikkilae, A.

    2009-01-01

    In this paper, multipoint near-infrared (NIR) spectroscopy is used in studying particulate pharmaceutical ingredients and their mixing and granulation processes. Homogeneous mixing of active pharmaceutical ingredients with excipients is essential in getting the correct dosage in the tableting phase. The basic principles of NIR spectroscopy and the associated molecular vibrations are briefly reviewed in the beginning of the work, followed by a summary of typical applications of NIR spectroscopy. A multipoint NIR measurement system developed at VTT is presented in this work. It consists of a spectral camera with fiber-optic inputs, a fiber-optic light source and twelve fiber-optic probes. The performance of the system in the laboratory is thoroughly reported, including signal-to-noise ratio, stability and probe-to-probe variability. The system was also tested in a fluidized bed granulator at Helsinki University. Eight probes were attached in two rows into the granulator, and several granulations were run. The mixing period in the beginning of the granulation process was clearly visible, as well as the changes in the moisture level during liquid spraying and final drying. The study shows that multipoint NIR spectroscopy is a valuable tool in monitoring the granulation process. In particular, it gives information about the macroscopic homogeneity of the fluidized bed. (orig.)

  7. Multipoint-NIR-measurements in pharmaceutical powder applications

    Energy Technology Data Exchange (ETDEWEB)

    Heikkilae, A.

    2009-01-15

    In this paper, multipoint near-infrared (NIR) spectroscopy is used in studying particulate pharmaceutical ingredients and their mixing and granulation processes. Homogeneous mixing of active pharmaceutical ingredients with excipients is essential in getting the correct dosage in the tableting phase. The basic principles of NIR spectroscopy and the associated molecular vibrations are briefly reviewed in the beginning of the work, followed by a summary of typical applications of NIR spectroscopy. A multipoint NIR measurement system developed at VTT is presented in this work. It consists of a spectral camera with fiber-optic inputs, a fiber-optic light source and twelve fiber-optic probes. The performance of the system in the laboratory is thoroughly reported, including signal-to-noise ratio, stability and probe-to-probe variability. The system was also tested in a fluidized bed granulator at Helsinki University. Eight probes were attached in two rows into the granulator, and several granulations were run. The mixing period in the beginning of the granulation process was clearly visible, as well as the changes in the moisture level during liquid spraying and final drying. The study shows that multipoint NIR spectroscopy is a valuable tool in monitoring the granulation process. In particular, it gives information about the macroscopic homogeneity of the fluidized bed. (orig.)

  8. Role of the urethral plate characters in the success of tubularized incised plate urethroplasty

    Directory of Open Access Journals (Sweden)

    Hamdy Aboutaleb

    2014-01-01

    Full Text Available Background: Today, tubularized incised plate (TIP urethroplasty is the most commonly performed operation for distal and mid-penile hypospadias. Reports from different centers worldwide confirm its nearly universal applicability and low complications rate. Aim: Evaluation of the urethral plate characters and its effect on the outcome of TIP urethroplasty. Materials and Methods: Between 2010 and 2013, 100 children with primary distal penile hypospadias underwent TIP urethroplasty. Urethral plates were categorized as flat, cleft, and deeply grooved. Postoperatively, patients were followed-up for evaluation of meatal stenosis, fistula formation, and glandular dehiscence at 1 st , 3 rd and 6 th months. Patients were followed-up for urethral calibration by urethral sound 8 Fr at 3 rd and 6 months follow-up. Data were statistically analysed using Epi info program to correlate between the width, plate shape, and complications. Results: Mean age at surgery was 4.3 years. Patients were followed-up for an average period of 6.4 months. Pre-operative location of the meatus was reported as coronal in 46, subcoronal in 50 and anterior penile in 4 cases. Urethral plate characters were flat in 26 cases, cleft in 52, and deeply grooved in 22. Urethral plate width was >8 mm in 74 cases and 8 mm. In addition, we also founds higher fistula rate and failed 8 Fr calibrations in flat urethral plate. Conclusions: An adequate urethral plate width (>8 mm is essential for successful TIP repair. Lower success rates with flat plates may need buccal mucosal augmentation to improve the results.

  9. European Hernia Society guidelines on the closure of abdominal wall incisions

    DEFF Research Database (Denmark)

    Muysoms, F E; Antoniou, S A; Bury, K

    2015-01-01

    BACKGROUND: The material and the surgical technique used to close an abdominal wall incision are important determinants of the risk of developing an incisional hernia. Optimising closure of abdominal wall incisions holds a potential to prevent patients suffering from incisional hernias and for im...

  10. Performance of fast-absorbable suture and histo-glue in closing incisions in Brown trout

    DEFF Research Database (Denmark)

    Jepsen, Niels; Larsen, Martin Hage; Aarestrup, Kim

    2017-01-01

    , growth, tag expulsion rate and incision healing was compared among three groups of dummy transmitter-tagged wild brown trout Salmo trutta where incisions were closed with two types of suture material (absorbable vs. fast absorbable) and Histo-glue. The tagged fish were kept in semi-natural ponds for 20...

  11. Midline versus transverse incision for cesarean delivery in low-income countries

    DEFF Research Database (Denmark)

    Maaløe, Nanna; Aabakke, Anna J M; Secher, Niels J

    2014-01-01

    While transverse incision is the recommended entry technique for cesarean delivery in high-income countries, it is our experience that midline incision is still used routinely in many low-income settings. Accordingly, international guidelines lack uniformity on this matter. Although evidence...

  12. Influence of upper and temporal transconjunctival sclerocorneal incision on marginal reflex distance after cataract surgery.

    Science.gov (United States)

    Tamaki, Rikiya; Gosho, Masahiko; Mizumoto, Kyoichi; Kato, Nahoko; Zako, Masahiro

    2016-07-07

    Ptosis incidence following cataract surgery is reduced with a recently developed phacoemulsification technique using a small incision. However, it remains uncertain whether an upper transconjunctival sclerocorneal incision can cause minor blepharoptosis. In the present prospective study, patients underwent cataract surgery with either an upper or temporal 2.4-mm transconjunctival sclerocorneal incision. We measured the marginal reflex distance 1 (MRD1) preoperatively and postoperatively, and compared these measurements between the two different incision types. Further we explored the risk factors of the postoperative MRD1 reduction. The study population included patients who underwent cataract surgery on both eyes at Aichi Medical University between October 2013 and September 2015. In each patient, one eye was operated using an upper 2.4-mm transconjunctival sclerocorneal incision, and the other with a temporal incision. We prespecified that an MRD1 difference of ≥0.5 mm between the pre- and post-surgical measurements indicated postoperative ptosis, which was a strict criterion. MRD1 was measured using digital photography, and we calculated the difference between the preoperative and postoperative MRD1 values. This change in MRD1 was compared between the groups with different incision locations. The change in MRD1 was analyzed by using the multivariate regression model including incision position (temporal or upper), preoperative MRD1, and preoperative distance between medial and lateral canthi. We assessed data from a total of 34 patients. The mean change in MRD1 from pre-operation to post-operation measurements was -0.26 ± 0.93 with the temporal incision and -0.24 ± 0.86 with the upper incision. The mean difference in the change in MRD1 between the different two incision types was -0.02, with a 95 % CI of -0.24 to 0.20, establishing equivalence between these incision types. The multivariate regression analysis showed that the preoperative MRD1 was

  13. Transscleral tunnel incision related arterial hemorrhage in 23-gauge Vitrectomy: case report.

    Science.gov (United States)

    Liu, Bingqian; Li, Yonghao; Li, Tao; Lin, Ying; Ma, Wei; Lu, Lin

    2018-01-17

    Transscleral tunnel incisions are commonly made to avoid postoperative leakage in small gauge sutureless vitrectomy. We present an unreported intraoperative complication, tunnel incision related arterial hemorrhage from sclerotomy, in 23-gauge (23G) vitrectomy. Two cases of intraocular arterial hemorrhage from superonasal sclerotomy were observed at the beginning of vitrectomy. The bleeding filled the vitreous cavity quickly and gushed out from the incision port after the involved supronasal cannula was removed. The active bleeding seemed not to stop spontaneously. We controlled the active bleeding by relocating the involved cannula, elevating the intraocular pressure and compressing the sclera wound. Post-operative intraocular hemorrhage from the sclerotomy was not found in any of the two cases. We suggest that the bleeding was from injured ciliary artery when the incision crossed 3 or 9 o'clock accidently. Surgeons might avoid this complication by locating the superior incisions away from the horizontal axis, and should be aware the proper management.

  14. A simple novel technique [PUIT] for closure of urethrocutaneous fistula after hypospadias repair: Preliminary results

    Directory of Open Access Journals (Sweden)

    Awad M

    2005-01-01

    Full Text Available Urethrocutaneous fistula is a common complication of urethroplasty for severe hypospadias, even when a microsurgical technique is applied, the closure of the fistula is a challenging problem. We present a simple surgical procedure, posterior urethral incision technique [PUIT] to close the fistula in our department. Between February 2001 and December 2004 we prospectively evaluated 32 patients, 26 patients with initial hypospadias fistulas and 6 with recurrent fistulas who underwent closure of urethrocutaneous fistula after hypospadias repair. The mean age of patients was 5 years, the operation consisted of trimming the fistula edge after mobilization of the skin all-around then a midline posterior urethral incision was done 2 mm above and 2 mm below the fistula opening then re-approximation of the urethral edges using 6/0 vicryl sutures with loop magnification. The timing of fistula repair was between 6 and 13 months after it was formed, all of these were effectively closed except three cases with stricture and fistula. Of these, two were completely relieved after repeated urethral dilatation, three times a week for 2 weeks. The third failed case will need another sitting after 6 months. The posterior midline urethral incision gives a good opportunity for repair without tension with a good cosmetic outcome. This may be done under local anesthesia in adults. The procedure is considered simple rapid and easy to be done for variable fistulas types whatever of its site and the age.

  15. Two-stage repair in hypospadias

    Directory of Open Access Journals (Sweden)

    K N Haxhirexha

    2008-01-01

    Full Text Available We provide the reader with a nonsystematic review concerning the use of the two-stage approach in hypospadias repairs. A one-stage approach using the tubularized incised plate urethroplasty is a well-standardized approach for the most cases of hypospadias. Nevertheless, in some primary severe cases, in most hypospadias failures and in selected patients with balanitis xerotica obliterans a two-stage approach is preferable. During the first stage the penis is straightened, if necessary and the urethral plate is substituted with a graft of either genital (prepuce or extragenital origin (oral mucosa or postauricular skin. During the second stage, performed around 6 months later, urethroplasty is accomplished by graft tubulization. Graft take is generally excellent, with only few cases requiring an additional inlay patch at second stage due to graft contracture. A staged approach allows for both excellent cosmetic results and a low morbidity including an overall 6% fistula rate and 2% stricture rate. Complications usually occur in the first year after the second stage and are higher in secondary repairs. Complications tend to decrease as experience increases and use of additional waterproofing layers contributes to reduce the fistula rate significantly. Long-term cosmetic results are excellent, but voiding and ejaculatory problems may occur in as much as 40% of cases if a long urethral tube is constructed. The procedure has a step learning curve but because of its technical simplicity does not require to be confined only to highly specialized centers.

  16. Sports hernia repair with adductor tenotomy.

    Science.gov (United States)

    Harr, J N; Brody, F

    2017-02-01

    Sports hernias, or athletic pubalgia, is common in athletes, and primarily involves injury to the fascia, muscles, and tendons of the inguinal region near their insertion onto the pubic bone. However, management varies widely, and rectus and adductor tenotomies have not been adequately described. The purpose of this manuscript is to demonstrate a suture repair and a rectus and adductor longus tenotomy technique for sports hernias. After magnetic-resonance-imaging confirmation of sports hernias with rectus and adductor tendonitis, 22 patients underwent a suture herniorrhaphy with adductor tenotomy. The procedure is performed through a 4-cm incision, and a fascial release of the rectus abdominis and adductor tenotomy is performed to relieve the opposing vector forces on the pubic bone. All 22 patients returned to their respective sports and regained their ability to perform at a high level, including professional status. No further surgery was required. In athletes with MRI confirmation of rectus and adductor longus injuries, tenotomies along with a herniorraphy may improve outcomes. A suture repair to reinforce the inguinal floor prevents mesh-related complications, especially in young athletes.

  17. Recent, climate-driven river incision rate fluctuations in the Mercantour crystalline massif, southern French Alps

    Science.gov (United States)

    Petit, C.; Goren, L.; Rolland, Y.; Bourlès, D.; Braucher, R.; Saillard, M.; Cassol, D.

    2017-06-01

    We present a new geomorphological analysis of the Tinée River tributaries in the southern French Alps based on numerical inverse and forward modelling of their longitudinal profiles. We model their relative uplift history with respect to the main channel, hence the incision rate history of this channel. Inverse models show that all tributaries have consistent incision rate histories with alternating high and low values. A comparison with global temperature curves shows that these variations correlate with quaternary climate changes. We suggest that during warm periods, a wave of regressive erosion propagates in the Tinée River, while its tributaries deeply incise their substratum to catch up with the falling base-level. We also show that the post 140 ka history of this landscape evolution is dominated by fluvial incision. We then perform forward models of river incision and simulate the incision of the Tinée River system over a time span of 600 ka. This model allows us to extract time and space incision rate variations of the Tinée River. With a background of a few mm.yr-1, incision rate can increase up to more than 1 cm yr-1 during short periods of time due to climatic oscillations. This result is compatible with published cosmogenic nuclide based dating, which evidenced incision rates from 0.2 to 24 mm yr-1. The part of the channel located between 12 and 20 km downstream from the source has undergone several periods of rapid incision rates, which could explain the steep hillslopes and the triggering of a landslide ∼10 ka ago.

  18. Plasmonic nanostructure assisted HHG in NIR spectrum and thermal analysis

    Science.gov (United States)

    Ebadian, H.; Mohebbi, M.

    2018-02-01

    We study plasmonic nanoparticle assisted high-order harmonic generation (HHG), illuminated by near infrared (NIR) laser sources, and the effect of the geometry of some different dimers on HHG cutoff frequency is evaluated. Dimers are installed on different dielectric substrates and the electric field enhancement factors are simulated. We demonstrate that NIR femto-fiber sources are good options for the HHG process. Such sources can induce significant inhomogeneous electric fields in the nanogaps; and consequently, high harmonic cutoff orders more than 250 will be obtained. Moreover, by time dependent thermal analysis of Au nanoparticles exposed to NIR ultrafast high power lasers, we could determine the temperature distribution in the nanoparticle and substrate.

  19. 'Regular' and 'emergency' repair

    International Nuclear Information System (INIS)

    Luchnik, N.V.

    1975-01-01

    Experiments on the combined action of radiation and a DNA inhibitor using Crepis roots and on split-dose irradiation of human lymphocytes lead to the conclusion that there are two types of repair. The 'regular' repair takes place twice in each mitotic cycle and ensures the maintenance of genetic stability. The 'emergency' repair is induced at all stages of the mitotic cycle by high levels of injury. (author)

  20. fNIRS-based brain-computer interfaces: a review.

    Science.gov (United States)

    Naseer, Noman; Hong, Keum-Shik

    2015-01-01

    A brain-computer interface (BCI) is a communication system that allows the use of brain activity to control computers or other external devices. It can, by bypassing the peripheral nervous system, provide a means of communication for people suffering from severe motor disabilities or in a persistent vegetative state. In this paper, brain-signal generation tasks, noise removal methods, feature extraction/selection schemes, and classification techniques for fNIRS-based BCI are reviewed. The most common brain areas for fNIRS BCI are the primary motor cortex and the prefrontal cortex. In relation to the motor cortex, motor imagery tasks were preferred to motor execution tasks since possible proprioceptive feedback could be avoided. In relation to the prefrontal cortex, fNIRS showed a significant advantage due to no hair in detecting the cognitive tasks like mental arithmetic, music imagery, emotion induction, etc. In removing physiological noise in fNIRS data, band-pass filtering was mostly used. However, more advanced techniques like adaptive filtering, independent component analysis (ICA), multi optodes arrangement, etc. are being pursued to overcome the problem that a band-pass filter cannot be used when both brain and physiological signals occur within a close band. In extracting features related to the desired brain signal, the mean, variance, peak value, slope, skewness, and kurtosis of the noised-removed hemodynamic response were used. For classification, the linear discriminant analysis method provided simple but good performance among others: support vector machine (SVM), hidden Markov model (HMM), artificial neural network, etc. fNIRS will be more widely used to monitor the occurrence of neuro-plasticity after neuro-rehabilitation and neuro-stimulation. Technical breakthroughs in the future are expected via bundled-type probes, hybrid EEG-fNIRS BCI, and through the detection of initial dips.

  1. fNIRS-based brain-computer interfaces: a review

    Directory of Open Access Journals (Sweden)

    Noman eNaseer

    2015-01-01

    Full Text Available A brain-computer interface (BCI is a communication system that allows the use of brain activity to control computers or other external devices. It can, by bypassing the peripheral nervous system, provide a means of communication for people suffering from severe motor disabilities or in a persistent vegetative state. In this paper, brain-signal generation tasks, noise removal methods, feature extraction/selection schemes, and classification techniques for fNIRS-based BCI are reviewed. The most common brain areas for fNIRS BCI are the primary motor cortex and the prefrontal cortex. In relation to the motor cortex, motor imagery tasks were preferred to motor execution tasks since possible proprioceptive feedback could be avoided. In relation to the prefrontal cortex, fNIRS showed a significant advantage due to no hair in detecting the cognitive tasks like mental arithmetic, music imagery, emotion induction, etc. In removing physiological noise in fNIRS data, band-pass filtering was mostly used. However, more advanced techniques like adaptive filtering, independent component analysis, multi optodes arrangement, etc. are being pursued to overcome the problem that a band-pass filter cannot be used when both brain and physiological signals occur within a close band. In extracting features related to the desired brain signal, the mean, variance, peak value, slope, skewness, and kurtosis of the noised-removed hemodynamic response were used. For classification, the linear discriminant analysis method provided simple but good performance among others: support vector machine, hidden Markov model, artificial neural network, etc. fNIRS will be more widely used to monitor the occurrence of neuro-plasticity after neuro-rehabilitation and neuro-stimulation. Technical breakthroughs in the future are expected via bundled-type probes, hybrid EEG-fNIRS BCI, and through the detection of initial dips.

  2. [Advances of NIR spectroscopy technology applied in seed quality detection].

    Science.gov (United States)

    Zhu, Li-wei; Ma, Wen-guang; Hu, Jin; Zheng, Yun-ye; Tian, Yi-xin; Guan, Ya-jing; Hu, Wei-min

    2015-02-01

    Near infrared spectroscopy (NIRS) technology developed fast in recent years, due to its rapid speed, less pollution, high-efficiency and other advantages. It has been widely used in many fields such as food, chemical industry, pharmacy, agriculture and so on. The seed is the most basic and important agricultural capital goods, and seed quality is important for agricultural production. Most methods presently used for seed quality detecting were destructive, slow and needed pretreatment, therefore, developing one kind of method that is simple and rapid has great significance for seed quality testing. This article reviewed the application and trends of NIRS technology in testing of seed constituents, vigor, disease and insect pests etc. For moisture, starch, protein, fatty acid and carotene content, the model identification rates were high as their relative contents were high; for trace organic, the identification rates were low as their relative content were low. The heat-damaged seeds with low vigor were discriminated by NIRS, the seeds stored for different time could also been identified. The discrimination of frost-damaged seeds was impossible. The NIRS could be used to identify health and infected disease seeds, and did the classification for the health degree; it could identify parts of the fungal pathogens. The NIRS could identify worm-eaten and health seeds, and further distinguished the insect species, however the identification effects for small larval and low injury level of insect pests was not good enough. Finally, in present paper existing problems and development trends for NIRS in seed quality detection was discussed, especially the single seed detecting technology which was characteristic of the seed industry, the standardization of its spectral acquisition accessories will greatly improve its applicability.

  3. Important NIR brightening of the Blazar PKS1244-255

    Science.gov (United States)

    Carrasco, L.; Recillas, E.; Porras, A.; Escobedo, G.; Chavushyan, V.

    2018-02-01

    We report on NIR photometry of the flat spectrum radio source PKS1244-255, cross identified with the intermediate redshift quasar CGRaBSJ1246-2547 (z=0.633) and the Gamma-ray source 3FGL1246.7-2547, We observed the source in the NIR, finding that on January 27th, 2017 (MJD 2458145.970579) its fluxes corresponded to J = 13.895 +/- 0.03, H = 12.937 +/- 0.02 and Ks = 12.042 +/- 0.04.

  4. Dynamic Filtering Improves Attentional State Prediction with fNIRS

    Science.gov (United States)

    Harrivel, Angela R.; Weissman, Daniel H.; Noll, Douglas C.; Huppert, Theodore; Peltier, Scott J.

    2016-01-01

    Brain activity can predict a person's level of engagement in an attentional task. However, estimates of brain activity are often confounded by measurement artifacts and systemic physiological noise. The optimal method for filtering this noise - thereby increasing such state prediction accuracy - remains unclear. To investigate this, we asked study participants to perform an attentional task while we monitored their brain activity with functional near infrared spectroscopy (fNIRS). We observed higher state prediction accuracy when noise in the fNIRS hemoglobin [Hb] signals was filtered with a non-stationary (adaptive) model as compared to static regression (84% +/- 6% versus 72% +/- 15%).

  5. Single transverse extended incision for radical neck dissection.

    Science.gov (United States)

    Chagas, José Francisco Sales; Pascoal, Maria Beatriz Nogueira; Aquino, José Luís Braga; Brandi, Luís Antônio; Previtale, Evandro Von Zuben; Trillo, Ana Sofia Pontes; Curioni, Otávio Alberto; Rapoport, Abrão; Dedivitis, Rogério Aparecido

    2016-01-01

    to assess the efficacy of the single transverse extended cervical incision in radical neck dissection. we conducted a prospective study, from January 2008 to January 2009, with 18 patients undergoing surgical treatment of malignant tumors of the upper aero-digestive tract. The primary lesion was located in the oral cavity in eight cases, in the oropharynx in three, in the hypopharynx in three, in the larynx in two, in the maxillary sinus, and in one case, the primary injury was hidden. There were 29 neck dissections, eight bilateral and 10 unilateral (26 radical and three selective). Staging revealed nine patients with T4 tumor, one T3, six T2, one T1 and one Tx. Five patients were N0, nine N2b, one N2c and three N3. The average number of dissected lymph nodes was 34.25. We performed the neck dissection through a single incision located in the middle neck, coincident with the skinfold, with a length of about 2 to 3 cm behind the anterior edge of the trapezius muscle and 3 to 4 cm from the midline for the unilateral neck dissections. as complications, there were myocutaneous flap necrosis in one patient with prior radiation therapy, one lymphatic fistula, one dehiscence of the tracheostomy, one cervical abscess, one salivary fistula and one suture dehiscence. the single extended incision provides adequate exposure of the neck structures, without compromising surgical time, even in bilateral dissections. It does not compromise the resection of all cervical lymph nodes; it has excellent aesthetic and functional results and is easily associated with other approaches to resection of the primary tumor. verificar a eficácia da incisão cervical única, transversa e estendida, para o esvaziamento cervical radical. estudo prospectivo, de janeiro de 2008 a janeiro de 2009, de 18 pacientes submetidos a tratamento cirúrgico de tumores malignos da via aero-digestiva superior. A lesão primária se situava na cavidade oral em oito casos, na orofaringe em três, no seio

  6. Effect of incision design on interproximal bone loss of teeth adjacent to single implants. A randomized controlled clinical trial comparing intrasulcular vs paramarginal incision.

    Science.gov (United States)

    Girbés-Ballester, Paula; Viña-Almunia, Jose; Balaguer-Martí, Jose C; Peñarrocha-Diago, Miguel; Peñarrocha-Oltra, David

    2018-02-16

    To evaluate the effect of incision design in implant surgery on interproximal bone loss of posterior teeth adjacent to interdental single implants, comparing intrasulcular and paramarginal incision. A further aim was to assess the influence of the incision technique on peri-implant bone remodeling. A controlled randomized clinical trial was carried out in a University Clinic. All the patients received an interdental posterior single implant. The incision type was randomly divided into two groups: (a) intrasulcular or (b) paramarginal. Standardized periapical digital radiographs were made with the parallel technique and a silicone index individualized in each patient. Radiographs were made immediately after implant placement, at abutment connection, 6 and 12 months post-loading. Two radiographic reference points were detected at the interproximal aspect of the adjacent teeth: (A) the cementoenamel junction and (B) the most coronal aspect of the bone crest. The interproximal bone loss of the adjacent teeth was calculated as the difference from A to B between the different follow-up periods and baseline. Two different examiners evaluated the radiographic measurements twice. Sixty patients, each with one implant, were included, 30 in each group. A mean interproximal bone loss in teeth of 0.09 mm in the intrasulcular and 0.10 mm in the paramarginal group was found at 12 months post-loading. Mean peri-implant bone remodeling was 0.17 mm in the intrasulcular group and 0.15 mm in the paramarginal group. Differences between incision types were not statistically significant (p > .05). Both incision designs used to place interdental single implants resulted in minimum bone loss at the interproximal aspect of adjacent teeth. The incision design did not significantly influence the radiographically assessed interproximal bone loss nor peri-implant bone remodeling. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Mesh Plug Repair of Inguinal Hernia; Single Surgeon Experience

    Directory of Open Access Journals (Sweden)

    Ahmet Serdar Karaca

    2013-10-01

    Full Text Available Aim: Mesh repair of inguinal hernia repairs are shown to be an effective and reliable method. In this study, a single surgeon%u2019s experience with plug-mesh method performs inguinal hernia repair have been reported. Material and Method: 587 patients with plug-mesh repair of inguinal hernia, preoperative age, body / mass index, comorbid disease were recorded in terms of form. All of the patients during the preoperative and postoperative hernia classification of information, duration of operation, antibiotics, perioperative complications, and later, the early and late postoperative complications, infection, recurrence rates and return to normal daily activity, verbal pain scales in terms of time and postoperative pain were evaluated. Added to this form of long-term pain ones. The presence of wound infection was assessed by the presence of purulent discharge from the incision. Visual analog scale pain status of the patients was measured. Results: 587 patients underwent repair of primary inguinal hernia mesh plug. One of the patients, 439 (74% of them have adapted follow-ups. Patients%u2019 ages ranged from 18-86. Was calculated as the mean of 47±18:07. Follow-up period of the patients was found to be a minimum of 3 months, maximum 55 months. Found an average of 28.2±13.4 months. Mean duration of surgery was 35.07±4.00 min (min:22mn-max:52mn, respectively. When complication rates of patients with recurrence in 2 patients (0.5%, hematoma development (1.4% in 6 patients, the development of infection in 11 patients (2.5% and long-term groin pain in 4 patients (0.9% appeared. Discussion: In our experience, the plug-mesh repair of primary inguinal hernia repair safe, effective low recurrence and complication rates can be used.

  8. [Application of the xenogenic acellular dermal matrix membrane application used in the postoperative tissue shortage repair].

    Science.gov (United States)

    Bai, Yanxia; Yan, Liying; Zhang, Shaoqiang; Shao, Yuan; Yao, Xiaobao; Li, Honghui; Zhao, Ruimin; Zhao, Qian; Zhang, Pengfei; Yang, Qi

    2014-09-01

    To observe the short-term and long-term curative effect of the xenogenic acellular dermal matrix membrane (or joint muscle flap transfer) application used in the 82 cases postoperative tissue shortage repair that after the head neck carcinoma resection. To held the 82 cases head neck carcinoma postoperative mucosa shortage repaired after resection by the xenogenic acellular dermal matrix membrane (or joint muscle flap transfer), 65 cases mucosa shortage wound be directly covered by the repair membrane and the other 17 cases mucosa shortage wound be repaired by the tranfered muscle tissue flap with the repair membrane covered; 53 cases underwent additional postoperative radiotherapy between 2-4 weeks and follow-up in 1, 3, 6, 12, 18, 24, 30, 36, 48, 60 months and observed the operation site repair process through the electronic laryngoscope, observed the patients respiration, swallow, phonation function. Seventy-seven cases patients operation incision reached I phase healing standard, another 5 cases patients operation incision reached II phase healing standard because of the wound infection and fully-recovered through the local wound drainage,dressing process. All the patients tracheal cannula,the stomach tube be extubated successfully and without the local cicatricial constriction occurred. Seventy-eight cases follow up period reached 1 year including 53 cases who underwent postoperative radiotherapy, 49 cases follow up period reached 3 years including 32 cases who underwent postoperative radiotherapy, 14 cases follow up period reached 5 years including 12 cases who underwent postoperative radiotherapy. The patients with static local lesions discovered no reaction such as exclusion, allergy. The application of xenogenic acellular dermal matrix membrane (or joint muscle flap transfer used in in the postoperative tissue shortage repair that after the head neck carcinoma resection have several advantage such as comparatively easily implementation, operation safety

  9. A 980 nm laser-activated upconverted persistent probe for NIR-to-NIR rechargeable in vivo bioimaging.

    Science.gov (United States)

    Xue, Zhenluan; Li, Xiaolong; Li, Youbin; Jiang, Mingyang; Ren, Guozhong; Liu, Hongrong; Zeng, Songjun; Hao, Jianhua

    2017-06-01

    Long-lasting persistent luminescent nanoparticles (PLNPs) with efficient near-infrared (NIR) emission have emerged as a new generation of probes for in vivo optical bioimaging owing to their advantages of zero-autofluorescence benefited from the self-sustained emission after excitation, deep penetration depth, and a high signal-to-noise ratio. However, most of the PLNPs are charged by ultraviolet (UV) or visible light, remarkably limiting their applications for in vivo long-term bioimaging. Here we demonstrate 980 nm laser activated upconversion-PLNPs (UC-PLNPs) with efficient NIR emission. The NIR-emitting UC-PLNPs (Zn 3 Ga 2 GeO 8 :Yb/Er/Cr) were synthesized by a sol-gel method with subsequent calcination. Owing to the efficient energy-transfer between Er and Cr ions, these UC-PLNPs present long-lasting up to 15 h NIR emission at 700 nm after the excitation of a 980 nm laser; in which both excitation and emission bands fall within the biological transparent window. The results of in vitro/in vivo toxicity assessments indicate that UC-PLNPs after surface modification present low biotoxicity and side effects in living animals. More importantly, the synthesized UC-PLNPs can be effectively recharged by 980 nm laser to restore in vivo persistent bioimaging signals and can also be employed as nanoprobes for in vivo UC optical bioimaging. This is the first demonstration of rechargeable UC-PLNPs for NIR-to-NIR in vivo bioimaging. We believe that the synthesized UC-PLNPs by combining UC and persistent luminescence properties into a single host may have potential applications in the bioimaging area and pave the way for widely using PLNPs for in vivo renewable long-lasting bioimaging.

  10. A NIR phosphorescent osmium(ii) complex as a lysosome tracking reagent and photodynamic therapeutic agent.

    Science.gov (United States)

    Zhang, Pingyu; Wang, Yi; Qiu, Kangqiang; Zhao, Zhiqian; Hu, Rentao; He, Chuanxin; Zhang, Qianling; Chao, Hui

    2017-11-14

    A novel near infrared (NIR) phosphorescent osmium complex (Os1) was developed for lysosome tracking and photodynamic therapy. Owing to its NIR photophysical properties, cellular imaging ability and phototoxicity, it has advantages over its ruthenium analogue (Ru1).

  11. Increased rate of repair of ultraviolet-induced DNA strand breaks in mitogen stimulated lymphocytes

    International Nuclear Information System (INIS)

    Hamlet, S.M.; Lavin, M.F.; Jennings, P.A.; Queensland Univ., St. Lucia; Queensland Univ. St. Lucia

    1982-01-01

    Previous results have shown that phytohaemagglutinin-stimulated bovine lymphocytes exhibit a peak of ultraviolet-induced DNA repair synthesis 3 to 4 days after addition of mitogen. The level of repair synthesis was approximately tenfold higher than that in unstimulated lymphocytes. These studies have been extended to examine the rate of repair of strand breaks in U.V.-irradiated bovine lymphocytes. The extent of breakage of DNA was shown to be the same in mitogen-stimulated and unstimulated lymphocytes from two breeds of cattle, when determined by sedimentation of nucleoids on sucrose gradients. However, in mitogen-stimulated cells the time taken to repair DNA strand breaks was 6 hours compared with 12 hours in stationary phase lymphocytes after a U.V. dose of 5 J/m 2 . These results suggest that the increased rate of repair of strand breaks is due to the induction of enzymes involved at the post-incision stage of DNA repair. Thus the increased level of repair synthesis observed in earlier work correlates with an increased rate of repair of DNA strand breaks in phytohaemagglutinin-stimulated bovine lymphocytes. (author)

  12. DSC, FT-IR, NIR, NIR-PCA and NIR-ANOVA for determination of chemical stability of diuretic drugs: impact of excipients

    Directory of Open Access Journals (Sweden)

    Gumieniczek Anna

    2018-03-01

    Full Text Available It is well known that drugs can directly react with excipients. In addition, excipients can be a source of impurities that either directly react with drugs or catalyze their degradation. Thus, binary mixtures of three diuretics, torasemide, furosemide and amiloride with different excipients, i.e. citric acid anhydrous, povidone K25 (PVP, magnesium stearate (Mg stearate, lactose, D-mannitol, glycine, calcium hydrogen phosphate anhydrous (CaHPO4 and starch, were examined to detect interactions. High temperature and humidity or UV/VIS irradiation were applied as stressing conditions. Differential scanning calorimetry (DSC, FT-IR and NIR were used to adequately collect information. In addition, chemometric assessments of NIR signals with principal component analysis (PCA and ANOVA were applied.

  13. De Qeurvian Tenosynovitis: Clinical Outcomes of Surgical Treatment with Longitudinal and Transverse Incision

    Directory of Open Access Journals (Sweden)

    Arefah Dehghani Tafti

    2011-03-01

    Full Text Available AbstractObjectives: De Quervain disease is a mechanical tenosynovitis due to inadequacy volume between abductor pollicis longus, extensor pollicis brevis and their tunnel. Treatment methods include immobilization, steroid injections, and operation. For the first time Fritz De Quervain described surgical treatment of this disease. Since then, various ways of treatment have been reported. The purpose of this study is to compare the clinical outcomes of a longitudinal incision with a transverse incision in De Quervain disease.Methods: This was a randomized controlled clinical trial conducted in three hospitals in Iran, Yazd from March 2003 to September 2008. One hundred-twenty patients with De Quervain disease who did not respond to conservative treatment were operated with two different incisions. The patients were followed for three months to compare the surgical outcomes.Results: During a three month follow-up, a significant difference was shown between the two methods (p=0.03. Results of surgical treatment with longitudinal incision were excellent (only 5 hypertrophic scars, but there were 13 postoperative complaints with transverse incision.Conclusion: According to our findings, longitudinal incision in surgical treatment of De Quervain disease is better than transverse incision.

  14. THE EFFECT OF WOUND INCISION CARE USING HONEY AND POVIDONE IODINE 10%

    Directory of Open Access Journals (Sweden)

    M. Zakariya

    2017-07-01

    Full Text Available Introduction : Povidoe iodine often used in incision treatment. This study was aimed to explain the differences between honey and povidone iodine 10% on incision healing, were unknown. Method : This study used a true experiment design with 18 samples of 3 years old-male guinea pigs, divided into three groups. One-control group and 2 treatment groups. This classification was done randomize. The independent variable was used of honey and 10-% povidon iodin and the dependent variable was inflammation phase (squeezing, edema, plasma of incision and proliferation (granulation, incision edge unification, skin structure were assessed in the third and sixth days.  Data were collected by using observation of the signs both of inflammation and proliferation phase and analyzed using Chi Square with level of significance α ≤ 0.05. Result : Results showed that there was no significant difference in the third and sixth days inflammation. In contrast, a significant difference was obtained in the third and sixth days proliferation. Granulation (p< 0,05, incision edge unification (p< 0,05, establishment of skin structures (p< 0,05. Analysis : It can be concluded that the honey usage was proven to be more effective in accelerated incision healing, increasing proliferation and reduce any infection risks. Discussion : For future research there is neeed to conduct a microscopically observation of numerous changes in collagen, PMN-cell (neutrophile and MN-cell (lymphocyte and monocyte, inflammation and proliferation as well as incision healing process.

  15. Nuclear management in manual small incision cataract surgery by snare technique

    Directory of Open Access Journals (Sweden)

    Bhattacharya Debasish

    2009-01-01

    Full Text Available Manual small incision cataract surgery has evolved into a popular method of cataract surgery in India. However, in supra hard cataract, bringing out the whole nucleus through the sclerocorneal flap valve incision becomes difficult. A bigger incision required in such cataracts loses its value action, as the internal incision and corneal valve slips beyond the limbus into sclera. Struggling with the supra hard cataracts through a regular small incision. Phacofracture in the anterior chamber becomes a useful option in these cases. In the snare technique, a stainless steel wire loop when lassoed around the nucleus in the anterior chamber constricts from the equator, easily dividing the hardest of the nuclei into two halves. The wire loop constricts in a controlled way when the second cannula of snare is pulled. The divided halves can easily be brought out by serrated crocodile forceps. This nuclear management can be safely performed through a smaller sclerocorneal flap valve incision where the corneal valve action is retained within the limbus without sutures, and the endothelium or the incision is not disturbed. However, the technique requires space in the anterior chamber to maneuver the wire loop and anterior chamber depth more than 2.5 mm is recommended. Much evidence to this wonderful technique is not available in literature, as its popularity grew through live surgical workshops and small interactive conferences.

  16. Reproductive Outcome of Transcervical Uterine Incision in Unicornuate Uterus.

    Science.gov (United States)

    Xia, En-Lan; Li, Tin-Chiu; Choi, Sze-Ngar Sylvia; Zhou, Qiao-Yun

    2017-02-05

    The pregnancy outcome of the unicornuate uterus is associated with an increased risk of miscarriage, cervical incompetence, and a number of obstetric complications. However, at present, there is no accepted treatment method for women with unicornuate uterus, other than expectant measures. The aim of this study was to evaluate the reproductive outcome of transcervical uterine incision (TCUI) in patients with unicornuate uterus. Thirty-three patients with unicornuate uterus presented to our tertiary center for infertility or miscarriage. All 33 patients underwent TCUI and were followed up for 10-52 months. The pregnancy outcomes ( first-trimester miscarriage, second-trimester miscarriage, preterm, term, intrauterine death, ongoing pregnancy, and live birth) before and after TCUI were compared by t- test. Among 31 patients who attempted to conceive after TCUI, twenty conceived including one termination of pregnancy, one second-trimester miscarriage, one ectopic pregnancy, five preterm deliveries, 11 term delivery, and one ongoing pregnancy. There were 16 live births in total. There was significant reduction in the first-trimester miscarriage rate (t = 4.890; Puterus presenting with infertility or miscarriage.

  17. Small incision lenticule extraction (SMILE) monovision for presbyopia correction.

    Science.gov (United States)

    Luft, Nikolaus; Siedlecki, Jakob; Sekundo, Walter; Wertheimer, Christian; Kreutzer, Thomas C; Mayer, Wolfgang J; Priglinger, Siegfried G; Dirisamer, Martin

    2017-11-04

    To evaluate the outcomes of myopic small incision lenticule extraction (SMILE) monovision in presbyopic patients. This study included 49 presbyopic patients older than 45 years seeking surgical correction of myopia or myopic astigmatism who underwent bilateral SMILE with planned monovision in the SMILE Eyes Clinic Linz, Austria. Target refraction was plano for dominant (distance) eyes and ranged between -1.25 and -0.50 D for nondominant (near) eyes. Best-corrected distance visual acuity, uncorrected distance visual acuity (UDVA), uncorrected near visual acuity, as well as spectacle dependence were assessed after a mean postoperative period of 7.2 ± 4.8 months. Mean age was 49 ± 3 years and female to male ratio was 30:19. Distance eyes achieved a spherical equivalent correction of ±0.50 D from target refraction in 80% of patients and 96% were within ±1.0 D. Binocular UDVA of 20/20 or better was achieved by 90% of patients and all patients achieved 20/25 or better. The proportion of patients with a binocular UDVA of 20/20 or better who could read J2 or better amounted to 84%. Complete spectacle independence was achieved by 84% of patients and independence from reading glasses was achieved in 92% of cases. No patient requested refractive enhancement or monovision reversal. This first evaluation of SMILE monovision endorses the approach as a safe and effective option for the correction of presbyopia in myopic patients seeking refractive surgery.

  18. Single-Incision Laparoscopic Sterilization of the Cheetah (Acinonyx jubatus).

    Science.gov (United States)

    Hartman, Marthinus J; Monnet, Eric; Kirberger, Robert M; Schmidt-Küntzel, Anne; Schulman, Martin L; Stander, Jana A; Stegmann, George F; Schoeman, Johan P

    2015-07-01

    To describe laparoscopic ovariectomy and salpingectomy in the cheetah (Acinonyx jubatus) using single-incision laparoscopic surgery (SILS). Prospective cohort. Female cheetahs (Acinonyx jubatus) (n = 21). Cheetahs were randomly divided to receive either ovariectomy (n = 11) or salpingectomy (n = 10). The use and complications of a SILS port was evaluated in all of cheetahs. Surgery duration and insufflation volumes of carbon dioxide (CO2 ) were recorded and compared across procedures. Laparoscopic ovariectomy and salpingectomy were performed without complications using a SILS port. The poorly-developed mesosalpinx and ovarian bursa facilitated access to the uterine tube for salpingectomy in the cheetah. The median surgery duration for ovariectomy was 24 minutes (interquartile range 3) and for salpingectomy was 19.5 minutes (interquartile range 3) (P = .005). The median volume of CO2 used for ovariectomy was 11.25 L (interquartile range 3.08) and for salpingectomy was 4.90 L (interquartile range 2.52), (P = .001) CONCLUSIONS: Laparoscopic ovariectomy and salpingectomy can be performed in the cheetah using SILS without perioperative complications. Salpingectomy is faster than ovariectomy and requires less total CO2 for insufflation. © Copyright 2015 by The American College of Veterinary Surgeons.

  19. Surgical incision can alter capsaicin-induced central sensitization in rat brainstem nociceptive neurons.

    Science.gov (United States)

    Lam, D K; Sessle, B J; Hu, J W

    2008-10-15

    Surgical trauma can affect spinal neuronal excitability, but there have been no studies of the effects of surgical cutaneous injury on central nociceptive processing of deep afferent inputs evoked by noxious stimuli such as capsaicin. Thus our aim was to test the effect of surgical cutaneous incision in influencing central sensitization induced by capsaicin injection into the temporomandibular joint (TMJ). The activity of single nociceptive neurons activated by noxious mechanical stimulation of the TMJ was recorded in the trigeminal subnucleus caudalis/upper cervical cord of halothane-anesthetized rats. The cutaneous mechanoreceptive field (RF), cutaneous mechanical activation threshold (MAT) and TMJ MAT of neurons before and after both surgical cutaneous incision alone and capsaicin injection were compared with results of incision and lidocaine pretreatment of the facial skin overlying the TMJ and capsaicin injection into the TMJ. Incision itself induced a barrage of neuronal spikes and excitability increases reflecting central sensitization (cutaneous RF expansion, cutaneous MAT reduction) in most neurons tested whereas lidocaine pretreatment significantly attenuated the barrage and central sensitization. Capsaicin injection into the TMJ induced cutaneous RF expansion, cutaneous MAT reduction and TMJ MAT reduction following lidocaine pretreatment of the cutaneous incision site whereas capsaicin injection following incision alone not only failed to induce further central sensitization but also decreased the existing incision-induced central sensitization (no cutaneous RF expansion, increased cutaneous MAT and TMJ MAT) in most neurons tested. These findings suggest that central sensitization induced by capsaicin alone or by cutaneous incision alone can readily occur in TMJ-responsive nociceptive neurons and that following incision-induced excitability increases, capsaicin may result in a temporary suppression of nociceptive neuronal changes reflecting central

  20. Incision rate changes in the upper Var River catchment, southern French Alps: from observations to models.

    Science.gov (United States)

    Petit, Carole; Rolland, Yann; Goren, Liran; Bourlès, Didier; Braucher, Régis; Saillard, Marianne; Cassol, Davide

    2017-04-01

    Cosmic Ray Exposure (CRE) dating on river polished surfaces from gorges located in the Var River catchment (Southern French Alps) reveals high incision rate pulses (>10 mm.yr-1) related with climate changes, and in particular with glacial-interglacial transitions. In addition, they show that the onset of the last deglaciation in this area occurred shortly after the Last Glacial Maximum (LGM), i.e. 16-19 ka ago. Extrapolating these results to longer time scales suggests that the post 140 ka history of this landscape was dominated by fluvial incision. Inverse models based on the stream power law are then used to determine uplift rate variations in several small tributaries of this catchment with respect to the main channel. These inverse models show that all tributaries have consistent incision rate histories with alternating high and low values, and a comparison with global temperature curves shows that these variations significantly correlate with quaternary climate changes. We suggest that during warm periods, a wave of regressive erosion propagates in the main channel, while its tributaries deeply incise their substratum to catch up with the falling base-level. We then perform forward models of river incision and simulate the incision of the main channel system over a time span of 600 ka. This model allows us to extract time and space incision rate variations along the Tinée River channel (the largest tributary of the Var River). With a background of a few mm.yr-1, incision rate can increase up to more than 10 mm.yr-1 during short episodes, in agreement with CRE dating. The part of the channel located between 12 and 20 km downstream from the source has undergone several periods of rapid incision rates, which could explain the steep hillslopes and the triggering of a landslide 10 kyr ago.

  1. Repairing fuel for reinsertion

    International Nuclear Information System (INIS)

    Cruickshank, A.

    1985-01-01

    The tools and techniques developed in the United States and FR Germany to repair damaged fuels assemblies are examined. Two methods of repair are considered:- removal of damaged fuel rods and replacement with sound rods (reconstitution); and removal of sound rods from one assembly structure and placing them into a fresh assembly structure (reassembly). (UK)

  2. Rare-Earth-Based Nanoparticles with Simultaneously Enhanced Near-Infrared (NIR)-Visible (Vis) and NIR-NIR Dual-Conversion Luminescence for Multimodal Imaging.

    Science.gov (United States)

    Ma, Dandan; Xu, Xiang; Hu, Min; Wang, Jing; Zhang, Zhenxi; Yang, Jian; Meng, Lingjie

    2016-04-05

    Multifunctional NaGdF4 :Yb(3+),Er(3+),Nd(3+) @NaGdF4 :Nd(3+) core-shell nanoparticles (called Gd:Yb(3+),Er(3+),Nd(3+) @Gd:Nd(3+) NPs) with simultaneously enhanced near-infrared (NIR)-visible (Vis) and NIR-NIR dual-conversion (up and down) luminescence (UCL/DCL) properties were successfully synthesized. The resulting core-shell NPs simultaneously emitted enhanced UCL at 522, 540, and 660 nm and DCL at 980 and 1060 nm under the excitation of a 793 nm laser. The enhanced UCL and DCL can be explained by complex energy-transfer processes, Nd(3+) →Yb(3+) →Er(3+) and Nd(3+) →Yb(3+) , respectively. The effects of Nd(3+) concentration and shell thickness on the UCL/DCL properties were systematically investigated. The UCL and DCL properties of NPs were observed under the optimal conditions: a shell Nd(3+) content of 20 % and a shell thickness of approximately 5 nm. Moreover, the Gd:Yb(3+) ,Er(3+) ,Nd(3+) @Gd:20 % Nd(3+) NPs exhibited remarkable magnetic resonance imaging (MRI) properties similar to that of a clinical agent, Omniscan. Thus, the core-shell NPs with excellent UCL/DCL/magnetic resonance imaging (MRI) properties have great potential for both in vitro and in vivo multimodal bioimaging. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. DNA repair protocols

    DEFF Research Database (Denmark)

    Bjergbæk, Lotte

    In its 3rd edition, this Methods in Molecular Biology(TM) book covers the eukaryotic response to genomic insult including advanced protocols and standard techniques in the field of DNA repair. Offers expert guidance for DNA repair, recombination, and replication. Current knowledge of the mechanisms...... that regulate DNA repair has grown significantly over the past years with technology advances such as RNA interference, advanced proteomics and microscopy as well as high throughput screens. The third edition of DNA Repair Protocols covers various aspects of the eukaryotic response to genomic insult including...... recent advanced protocols as well as standard techniques used in the field of DNA repair. Both mammalian and non-mammalian model organisms are covered in the book, and many of the techniques can be applied with only minor modifications to other systems than the one described. Written in the highly...

  4. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Bill Bruce; Nancy Porter; George Ritter; Matt Boring; Mark Lozev; Ian Harris; Bill Mohr; Dennis Harwig; Robin Gordon; Chris Neary; Mike Sullivan

    2005-07-20

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without

  5. VIS/NIR imaging application for honey floral origin determination

    NARCIS (Netherlands)

    Minaei, Saeid; Shafiee, Sahameh; Polder, Gerrit; Moghadam-Charkari, Nasrolah; Ruth, van Saskia; Barzegar, Mohsen; Zahiri, Javad; Alewijn, Martin; Kuś, Piotr M.

    2017-01-01

    Nondestructive methods are of utmost importance for honey characterization. This study investigates the potential application of VIS-NIR hyperspectral imaging for detection of honey flower origin using machine learning techniques. Hyperspectral images of 52 honey samples were taken in

  6. NIR monitoring of in-service wood structures

    Science.gov (United States)

    Michela Zanetti; Timothy G. Rials; Douglas Rammer

    2005-01-01

    Near infrared spectroscopy (NIRS) was used to study a set of Southern Yellow Pine boards exposed to natural weathering for different periods of exposure time. This non-destructive spectroscopic technique is a very powerful tool to predict the weathering of wood when used in combination with multivariate analysis (Principal Component Analysis, PCA, and Projection to...

  7. The recent NIR Flare of the Blazar 3C279

    Science.gov (United States)

    Carrasco, L.; Recillas, E.; Porras, A.; Escobedo, G.; Chavushyan, V.

    2018-02-01

    In our monitoring campaign of AGNs we found the Blazar 3C279 flaring in the NIR on January 27th,2018. this source is cross identified with the quasar HB891253-055 and the Gamma-ray source 3FGLJ1256.1-054.

  8. NIR Flare of radio source GB60713+5738

    Science.gov (United States)

    Carrasco, L.; Porras, A.; Recillas, E.; Chavushyan, V.

    2018-02-01

    In ATel#11331, we reported the NIR detection of the radio source GB60713+5738 and the suggestion of it being in flaring state. However, we found a previous observation in our archive that fully confirms a recent giant flare of this object.

  9. Greenhouse with a CPV system and NIR reflecting lamellae

    NARCIS (Netherlands)

    H.J.J. Janssen; B.A.J. van Tuijl; Gert-Jan Swinkels; Piet Sonneveld; G.P.A. Bot

    2012-01-01

    In previous research a new type of greenhouse with an integrated concentrated photovoltaic system (CPV) was developed based on a circular covering geometry and an integrated filter for reflecting the near infrared radiation (NIR) of the greenhouse and exploiting this radiation in a solar energy

  10. Design of a NIR concentrator system integrated in a greenhouse

    NARCIS (Netherlands)

    Piet Sonneveld; Gert-Jan Swinkels; H.J.J. Janssen; B.A.J. van Tuijl

    2012-01-01

    In this paper the design and development of a new type of greenhouse with an integrated filter for reflecting near infrared radiation (NIR) and a solar energy delivery system is described. Especially the optical parts as the spectral selective film, the properties of the circular reflector and the

  11. Solar Energy Delivering Greenhouse with an Integrated NIR filter

    NARCIS (Netherlands)

    Sonneveld, P.J.; Swinkels, G.L.A.M.; Holterman, H.J.; Tuijl, van B.A.J.; Bot, G.P.A.

    2008-01-01

    The scope of this investigation is the design and development of a new type of greenhouse with an integrated filter for rejecting near infrared radiation (NIR) and a solar energy delivery system. Cooled greenhouses are an important issue to cope with the combination of high global radiation and high

  12. New NIR light-curve templates for classical Cepheids

    NARCIS (Netherlands)

    Inno, L.; Matsunaga, N.; Romaniello, M.; Bono, G.; Monson, A.; Ferraro, I.; Iannicola, G.; Persson, E.; Buonanno, R.; Freedman, W.; Gieren, W.; Groenewegen, M.A.T.; Ita, Y.; Laney, C.D.; Lemasle, B.; Madore, B.F.; Nagayama, T.; Nakada, Y.; Nonino, M.; Pietrzyński, G.; Primas, F.; Scowcroft, V.; Soszyński, I.; Tanabé, T.; Udalski, A.

    2015-01-01

    Aims. We present new near-infrared (NIR) light-curve templates for fundamental (FU, J, H, KS) and first overtone (FO, J) classical Cepheids. The new templates together with period-luminosity and period-Wesenheit (PW) relations provide Cepheid distances from single-epoch observations with a precision

  13. TROPOMI and TROPI: UV/VIS/NIR/SWIR instruments

    NARCIS (Netherlands)

    Levelt, P.F.; Oord, G.H.J. van den; Dobber, M.; Eskes, H.; Weele, M. van; Veefkind, P.; Oss, R. van; Aben, I.; Jongma, R.T.; Landgraf, J.; Vries, J. de; Visser, H.

    2006-01-01

    TROPOMI (Tropospheric Ozone-Monitoring Instrument) is a five-channel UV-VIS-NIR-SWIR non-scanning nadir viewing imaging spectrometer that combines a wide swath (114°) with high spatial resolution (10 × 10 km 2). The instrument heritage consists of GOME on ERS-2, SCIAMACHY on Envisat and, especially,

  14. Less transpiration and good quality thanks to NIR-screen

    NARCIS (Netherlands)

    Stanghellini, C.; Kempkes, F.L.K.; Hemming, S.; Jianfeng, D.

    2009-01-01

    Materials or additives for greenhouse cover that reflect or absorb a part of the NIR radiation can decrease the cooling requirement for the greenhouse and increase water use efficiency of the crop. By reducing the ventilation requirement, it might even decrease emissions of carbon dioxide from

  15. Developing and evaluating a multisite and multispecies NIR ...

    African Journals Online (AJOL)

    To elevate NIR from proof-of-concept to a pilot scale, a large multisite, multispecies calibration was developed over iterative cycles to: (1) determine whether KPY in eucalypts can be predicted from a single calibration independent of site and species, and (2) identify the potential limits of accuracy and precision. This paper ...

  16. Greenhouse with a CPV system based on NIR reflecting lamellae

    NARCIS (Netherlands)

    Sonneveld, P.J.; Swinkels, G.L.A.M.; Tuijl, van B.A.J.; Janssen, H.J.J.; Bot, G.P.A.

    2012-01-01

    In previous research a new type of greenhouse with an integrated concentrated photovoltaic system (CPV) was developed based on a circular covering geometry and an integrated filter for reflecting the near infrared radiation (NIR) of the greenhouse and exploiting this radiation in a solar energy

  17. Techniques for creating inconspicuous face-lift scars: avoiding visible incisions and loss of temporal hair.

    Science.gov (United States)

    Kridel, Russell W H; Liu, Edmund S

    2003-01-01

    Patients seeking rhytidectomy desire an improved neckline, jawline, and midface, but rarely at the price of signs that betray a face-lift, namely, visible incisions. We describe our face-lift incisional planning and the rationale behind specific surgical maneuvers for preventing unwanted sequelae. The telltale signs of poorly placed incisions include temporal hair loss, conspicuous scars, an unnatural appearance to the tragus, and a posterior hairline distorsion. Special considerations are given to the male patient and to the salvage of readily visible incision lines from previous surgery.

  18. Towards achieving small-incision cataract surgery 99.8% of the time.

    Directory of Open Access Journals (Sweden)

    Thomas R

    2000-01-01

    Full Text Available A surgical approach designed to reliably attain the modern goal of small incision cataract surgery 99.8% of the time is described. Phacoemulsification as well as a manual small incision technique is utilised to achieve the desired outcome as often as possible and for all types of cataracts. The logic, and required surgical steps are described and illustrated. This surgical technique allows the advantages of small incision surgery to be reliably achieved. The method is flexible and allows decisions and steps to be modified depending on the skill and comfort zone of the individual surgeon.

  19. 7 CFR 801.7 - Reference methods and tolerances for near-infrared spectroscopy (NIRS) analyzers.

    Science.gov (United States)

    2010-01-01

    ... Association Method A-20, Analysis for Starch in Corn, Second revision, April 15, 1986, Standard Analytical... Method 992.23. (3) NIRS corn oil, protein, and starch analyzers. The maintenance tolerances for the NIRS... Starch method, Corn Refiners Association Method A-20. (4) NIRS barley protein analyzers. The maintenance...

  20. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

    2004-12-31

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without

  1. Phacoemulsification versus small incision cataract surgery in patients with uveitis

    Directory of Open Access Journals (Sweden)

    Rahul Bhargava

    2015-10-01

    Full Text Available AIM: To compare the safety and efficacy of phacoemulsification and small incision cataract surgery (SICS in patients with uveitic cataract.METHODS:In aprospective, randomized multi-centric study, consecutive patients with uveitic cataract were randomized to receive phacoemulsification or manual SICS by either of two surgeons well versed with both the techniques. A minimum inflammation free period of 3mo (defined as less than 5 cells per high power field in anterior chamber was a pre-requisite for eligibility for surgery. Superior scleral tunnel incisions were used for both techniques. Improvement in visual acuity post-operatively was the primary outcome measure and the rate of post-operative complications and surgical time were secondary outcome measures, respectively. Means of groups were compared using t-tests. One way analysis of variance (ANOVA was used when there were more than two groups. Chi-square tests were used for proportions. Kaplan Meyer survival analysis was done and means for survival time was estimated at 95% confidence interval (CI. A P value of <0.05 was considered statistically significant.RESULTS:One hundred and twenty-six of 139 patients (90.6% completed the 6-month follow-up. Seven patients were lost in follow up and another six excluded due to either follow-up less than six months (n=1 or inability implant an intraocular lens (IOL because of insufficient capsular support following posterior capsule rupture (n=5. There was significant improvement in vision after both the procedures (paired t-test; P<0.001. On first postoperative day, uncorrected distance visual acuity (UDVA was 20/63 or better in 31 (47% patients in Phaco group and 26 (43.3% patients in SICS group (P=0.384. The mean surgically induced astigmatism (SIA was 0.86±0.34 dioptres (D in the phacoemulsification group and 1.16±0.28 D in SICS group. The difference between the groups was significant (t-test, P=0.002. At 6mo, corrected distance visual acuity (CDVA

  2. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

    2004-08-17

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners

  3. Early clinical outcomes after small incision lenticule extraction surgery (SMILE).

    Science.gov (United States)

    Recchioni, Alberto; Hartwig, Andreas; Dermott, Jay; Vaswani, Sundeep; Bhatt, Jay; Morris, Robert; O'Donnell, Clare

    2018-02-01

    Dry eye is known to impact on clinical outcomes after laser vision correction and the use of a newer 'all femtosecond laser' surgical approach may be associated with less impact on the ocular surface post-operatively. The purpose of this study was to evaluate the early clinical outcomes and tear instability after the first small incision lenticule extraction (SMILE) cases undertaken by three surgeons at a single site in the UK. Retrospective audit. Seventy-one eyes of 37 patients underwent SMILE surgery using the Zeiss VisuMax laser system (Carl Zeiss Meditec, Germany). Uncorrected and corrected distance visual acuity, spherical equivalent refraction, fluorescein enhanced tear break up time, simulated keratometry and complications were evaluated pre- and post-operatively where applicable. The study population consisted of 21 males and 16 females. The mean±standard deviation age was 33±8years. The results showed that 100% of eyes achieved 20/40 or better and 88% achieved 20/20 or better uncorrected distance visual acuity. The spherical equivalent refraction after surgery was within ±0.50D in 82% of eyes at three months. There was no significant difference in tear break up time from pre-operative levels at three months. Complications were infrequent. This early data from surgeons' first SMILE procedures suggest SMILE provides good outcomes in terms of refractive predictability and visual acuity with minimal impact on the tear film. Longitudinal research will further improve our understanding of the longer-term impact of SMILE on clinical outcomes, ocular surface metrics and patient reported outcomes. Copyright © 2017. Published by Elsevier Ltd.

  4. Polydioxanone versus polypropylene closure for midline abdominal incisions

    International Nuclear Information System (INIS)

    Naz, S.; Jamali, M.A.

    2017-01-01

    Background: Midline laparotomy is the most common technique of abdominal incisions because it is simple, provides adequate exposure to all four quadrants, and is rapid to open. A major problem after midline laparotomy remains the adequate technique of abdominal fascia closure. This study was conducted to see the role of Polydioxanone and Prolene for midline abdominal closure in terms of postoperative wound infection and wound pain. Methods: This study was carried out at surgical unit II, Federal Government Services Hospital Islamabad. Patients were equally divided in two groups, i.e., A and B. Groups A and B patients undergone midline abdominal closure with Polydioxanone number 1 and Polypropylene number 1 sutures respectively. Results: Total 620 patients were included in this study. Post-operative wound pain score according to Visual analogue scale (VAS) was compared in terms of no pain (0), mild pain (1-3), moderate pain (4-6), severe pain (7-9). In group A (Polydioxanone), the frequency and percentages of no, mild, moderate and severe pain were 101 (32.6%), 95 (30.6%), 81 (26.1%) and 33 (10.6%) respectively, where as in group B (polypropylene) it was 82 (26.5%), 43 (13.9%), 59 (19%) and 126 (40.6%) respectively. Similarly, the frequency and percentages of post-operative wound infection in group A (Polydioxanone) and group B (polypropylene) was 105 (33.9%) and 208 (67.1%) respectively. Conclusion: Polydioxanone results in less wound pain and wound infection when compared to Polypropylene. (author)

  5. Office-based relaxing incision procedure for correction of astigmatism after deep anterior lamellar keratoplasty

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Javadi

    2017-01-01

    Conclusion: Office-based relaxing incision is a safe and effective procedure for the treatment of corneal graft astigmatism after DALK. This approach effectively decreases the need for the more costly alternative in the operating room.

  6. Relaxation incisions of venomous snake "Japanese mamushi" bites to the hand

    Directory of Open Access Journals (Sweden)

    Sugamata A

    2011-12-01

    Full Text Available Akira Sugamata, Naoki Yoshizawa, Takahiro OkadaDepartment of Plastic and Reconstructive Surgery, Tokyo Medical University Hachioji Medical Center, Tokyo, JapanAbstract: Gloydius blomhoffii, commonly known as Japanese mamushi, is a venomous viper species found widely in Japan. The most frequently bitten regions are the fingers and toes, and severe swelling causes compression of peripheral arteries and/or compartment syndrome of the extremities. We experienced four cases of mamushi bites to the hand, and undertook relaxation incision in the hands of three of these patients. As a result, the patients who underwent relaxation incision did not show any skin necrosis or permanent sensory disturbance in the affected fingers. Relaxation incision can be useful to not only decompress subcutaneous and compartment pressure of the hand, but also to wash out the venom from the bitten region by improving venous and lymphatic drainage.Keywords: mamushi, snakebite, viper, relaxation incision

  7. Type of incision does not predict abdominal wall outcome after emergency surgery for colonic anastomotic leakage

    DEFF Research Database (Denmark)

    Jensen, Kristian Kiim; Oma, Erling; Harling, Henrik

    2017-01-01

    PURPOSE: Most literature on abdominal incision is based on patients undergoing elective surgery. In a cohort of patients with anastomotic leakage after colonic cancer resection, we analyzed the association between type of incision, fascial dehiscence, and incisional hernia. METHODS: Data were...... extracted from the Danish Colorectal Cancer Group database and merged with information from the Danish National Patient Register. All patients with anastomotic leakage after colonic resection in Denmark from 2001 until 2008 were included and surgical records on re-operations were retrieved. The primary...... for anastomotic leakage were included with a median follow-up of 5.4 years. Incisional hernia occurred in 41 of 227 (15.3%) patients undergoing midline incision compared with 14 of 81 (14.7%) following transverse incision, P = 1.00. After adjusting for confounders, there was no association between the type...

  8. Induced astigmatism in a 6.0 mm no-stitch frown incision.

    Science.gov (United States)

    Sinskey, R M; Stoppel, J O

    1994-07-01

    Fifty-five consecutive patients had cataract extraction with a 6 mm no-stitch frown incision and implantation of a 6 mm optic three-piece posterior chamber lens. Vector analysis calculations of diopters (D) of mean induced keratometric astigmatism for this incision were 0.70 D at one day, 0.76 D at one week, 0.50 D at one month, and 0.50 D at three months. The Naeser's polar value showed a mean with-the-rule astigmatism of +0.42 D at one day and -0.08 D against-the-rule astigmatism at three months. The results suggest that the 6.0 mm no-stitch frown incision induces a low postoperative astigmatism and provides a stable incision.

  9. Intraoperative ventricular puncture during supraorbital craniotomy via an eyebrow incision. Technical note.

    NARCIS (Netherlands)

    Menovsky, T.; Vries, J. de; Wurzer, J.A.; Grotenhuis, J.A.

    2006-01-01

    The authors determined the landmarks and coordinates for intraoperative ventricular puncture directly from the supraorbital craniotomy opening via an eyebrow incision. Fifty magnetic resonance (MR) imaging studies were obtained from patients with no pathological cerebral characteristics or

  10. Erbium: YAG Laser Incision of Urethral Strictures for Treatment of Urinary Incontinence after Prostate Cancer Surgery

    National Research Council Canada - National Science Library

    Fried, Nathaniel

    2004-01-01

    .... The purpose of this research project is to test a new laser, the Erbium:YAG laser, which is capable of precisely incising the urethral stricture with minimal peripheral damage to adjacent healthy tissue...

  11. Salvage hypospadias repairs

    Directory of Open Access Journals (Sweden)

    Sripathi V

    2008-01-01

    Full Text Available Aim: Review of our experience and to develop an algorithm for salvage procedures in the management of hypospadias cripples and treatment of urethral strictures following hypospadias repair. Methods: This is a retrospective review of hypospadias surgeries over a 41-month period. Out of a total 168 surgeries, 20 were salvage/re-operative repairs. In three children a Duplay repair was feasible, while in four others a variety of single-stage repairs could be done. The repair was staged in seven children - buccal mucosal grafts (BMGs in five, buccal mucosal tube in one, and skin graft in one. Five children with dense strictures were managed by dorsal BMG inlay grafting in one, vascularized tunical onlay grafting on the ventrum in one, and a free tunical patch in one. Three children were treated by internal urethrotomy and stenting for four weeks with a poor outcome. Results: The age of children ranged from 1.5-15 years (mean 4.5. Follow-up ranged from 3 months to 3.5 years. Excellent results were obtained in 10 children (50% with a well-surfaced erect penis and a slit-like meatus. Glans closure could not be achieved and meatus was coronal in three. Two children developed fistulae following a Duplay repair and following a staged BMG. Three repairs failed completely - a composite repair broke down, a BMG tube stenosed with a proximal leak, and a stricture recurred with loss of a ventral free tunical graft. Conclusions: In salvage procedures performed on hypospadias cripples, a staged repair with buccal mucosa as an inlay in the first stage followed by tubularization 4-6 months later provides good results. A simple algorithm to plan corrective surgery in failed hypospadias cases and obtain satisfactory results is devised.

  12. Determination of Aluminium Content in Aluminium Hydroxide Formulation by FT-NIR Transmittance Spectroscopy

    DEFF Research Database (Denmark)

    Lai, Xuxin; Zheng, Yiwu; Søndergaard, Ib

    2007-01-01

    A method for determining the aluminium content of an aluminium hydroxide suspension using near infrared (NIR) transmittance spectroscopy has been developed. Inductively coupled plasma-atomic emission spectroscopy (ICP-AES) was used as reference method. The factors influencing the NIR analysis......-AES and NIR transmittance spectroscopy exhibit comparable precision and accuracy. The NIR method provides several advantages: no complicated sample preparation; easy to operate; fast and non-destructive. In conclusion, NIR transmittance spectroscopy can be an alternative analytical method for determining...

  13. [In hospital and mid-term outcome of patients with NIR stent implantation: multicenter ESPORT-NIR registry].

    Science.gov (United States)

    Iñiguez, A; García, E; Seabra, R; Bordes, P; Bethencourt, A; Rigla, J

    2001-05-01

    Despite improvements in the results and techniques of catheter-based revascularization, few studies have evaluated the clinical results of the application of new stent designs. We describe the in-hospital and mid-term outcome of patients undergoing a stent NIR implantation. At least 1 Stent NIR was implanted in 1.004 patients (1.136 lesions) recruited from 50 centers in an international, multicenter, prospective, registry (Spain and Portugal NIR stent registry). Inclusion criteria were objective coronary ischemia related to a severe de novo lesion or first restenosis in native vessels with a reference diameter >= 2.75 mm. The primary end-point was the incidence of major adverse cardiac events within the first 7 months of follow-up. The mean age of the patients was 60 years and 82% were male. Angioplasty was indicated due to unstable angina in 61% of the cases. Stent implantation was successfully achieved in 99.6%. Clinical success (angiographic success without in-hospital major events) was achieved in 98.6% of patients. The rate of angiographic restenosis (> 50% stenosis narrowing) was 16% (CI 95%; 11.7-21.2). The accumulated major cardiac adverse event rate at seven months of follow-up was 8.7%: death (0.9%), acute myocardial infarction (1.2%) and target lesion revascularization (6.6%). In the wide setting of the population included in the ESPORT-NIR registry, stent NIR implantation was a highly effective therapy with a good mid-term clinical and angiographic outcome.

  14. Repairing fuel for reinsertion

    International Nuclear Information System (INIS)

    Krukshenk, A.

    1986-01-01

    Eqiupment for nuclear reactor fuel assembly repairing produced by Westinghouse and Brawn Bovery companies is described. Repair of failed fuel assemblies replacement of defect fuel elements gives a noticeable economical effect. Thus if the cost of a new fuel assembly is 450-500 thousand dollars, the replacement of one fuel element in it costs approximately 40-60 thousand dollars. In simple cases repairing includes either removal of failed fuel elements from a fuel assembly and its reinsertion with the rest of fuel elements into the reactor core (reactor refueling), or replacement of unfailed fuel elements from one fuel assembly to a new one (fuel assembly overhaul and reconditioning)

  15. Influence of orographic precipitation on the incision within a mountain-piedmont system

    Science.gov (United States)

    Zavala, Valeria; Carretier, Sébastien; Bonnet, Stephane

    2017-04-01

    The geomorphological evolution of a mountain-piedmont system depends both on tectonics and climate, as well as on couplings between the mountain and its piedmont. Although the interactions between climate and tectonics are a fundamental point for understanding the landscape evolution, the erosion of a mountain range and the sediment deposition at the mountain front, or piedmont, have been poorly studied as a coupled system. Here we focus on the conditions driving an incision within such a system. Classically, it is thought that incision results from a change in climate or uplift rates. However, it is not clear which are the specific conditions that favor the occurrence of river incision in the piedmont. In particular, studies have shown that the presence of a piedmont can modify the incision patterns, and even drive autogenic incision, without any change in external forcings. This is a crucial issue in order to interpret natural incisions in terms of uplift or climatic modifications. Such a problem is further complicated by the modification of local precipitations and temperatures during uplift, because the progressive effect of climate change may superimpose to uplift. In this work we explore the hypothesis that a mountain-piedmont coupled system may develop incision in its piedmont as a result of enhanced orographic precipitations during surface uplift. We use a landscape evolution model, Cidre, in order to explore the response of a mountain-piemont system in which the mountain is continuously uplifted but in which precipitation rates depend on elevations. Thus precipitation amounts change during the mountain uplift. We test different peaks and amplitudes of the orographic precipitation pattern, maintaining the other conditions constant. Preliminary results show that elevation-dependent precipitations drive temporary but pronounced incisions of the main rivers within the piedmont, contrary to experiments without orographic precipitations.

  16. Clear corneal incisions in bimanual microincision cataract surgery: long-term wound-healing architecture.

    Science.gov (United States)

    Cavallini, Gian Maria; Campi, Luca; Torlai, Giulio; Forlini, Matteo; Fornasari, Elisa

    2012-10-01

    To evaluate bimanual microincision cataract surgery (MICS) clear corneal incision (CCI) architectural features over the long-term using anterior segment optical coherence tomography (AS-OCT). Case series. Institute of Ophthalmology, University of Modena, Modena, Italy. Patients who had uneventful bimanual MICS in the previous 2 to 16 months were examined using AS-OCT. Images were used to measure corneal thickness, incision length, incision angle, incidence of epithelial or endothelial gaping, misalignment, Descemet membrane detachment, and posterior wound retraction. Fifty-two eyes (33 patients) were enrolled. Mean incision length and incision angle were, respectively, 1427.91 μm and 31.19 degrees for the right hand, 1440.63 μm and 31.54 degrees for the left hand, 1474.13 μm and 31.27 degrees for temporal incisions, and 1394.41 μm and 31.46 degrees for nasal CCIs. Posterior wound retraction was the only architectural feature found. Its prevalence was 7.10% at 2 to 3 months, 31.8% at 4 to 11 months, and 33.3% at 12 months. Fifty-three percent of posterior wound retractions were in 1.8 mm CCIs and 47% in 1.4 mm CCIs. Bimanual MICS was not related to particular morphologic features of CCIs. The enlargement of 1 incision or construction of the incision with the dominant or the nondominant hand did not affect long-term wound architecture. Posterior wound retraction was the only architectural feature; however, its prevalence seems substantially lower than with other surgical techniques. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Spontaneous alignment of crowded inferior incisives after the extractionof temporary canines

    OpenAIRE

    Orellana Manrique, Tomás Oriel; Calderón Cortez, Iván; Orellana Manrique, Martín

    2014-01-01

    This investigation evaluated the behavior of permanent inferior incisives after the primary canine’s extractions. The study was carried out in the Pediatric Clinic of Dental Faculty of San Marcos University. The sample was conformed by 10 patients, male and female children, between 8 and 9 years of age, with good general health, having Class I malocclusion and severe crowding of the inferior incisives. It was taken Cephalometric and Panoramic radiographies, as well as models to make the ortho...

  18. Shed a light of wireless technology on portable mobile design of NIRS

    Science.gov (United States)

    Sun, Yunlong; Li, Ting

    2016-03-01

    Mobile internet is growing rapidly driven by high-tech companies including the popular Apple and Google. The wireless mini-NIRS is believed to deserve a great spread future, while there is sparse report on wireless NIRS device and even for the reported wireless NIRS, its wireless design is scarcely presented. Here we focused on the wireless design of NIRS devices. The widely-used wireless communication standards and wireless communication typical solutions were employed into our NIRS design and then compared on communication efficiency, distance, error rate, low-cost, power consumption, and stabilities, based on the requirements of NIRS applications. The properly-performed wireless communication methods matched with the characteristics of NIRS are picked out. Finally, we realized one recommended wireless communication in our NIRS, developed a test platform on wireless NIRS and tested the full properties on wireless communication. This study elaborated the wireless communication methods specified for NIRS and suggested one implementation with one example fully illustrated, which support the future mobile design on NIRS devices.

  19. Evaluation of four suture materials for surgical incision closure in Siberian sturgeon

    Science.gov (United States)

    Boone, S. Shaun; Hernandez, Sonia M.; Camus, Alvin C.; Peterson, Douglas C.; Jennings, Cecil A.; Shelton, James L.; Divers, Stephen J.

    2015-01-01

    The visual and microscopic tissue reactions to the absorbable monofilament Monocryl, absorbable monofilament triclosan-coated Monocryl-Plus, absorbable multifilament Vicryl, and nonabsorbable monofilament Prolene were evaluated for their use of surgical closure in Siberian Sturgeon Acipenser baerii. Postoperative assessments were conducted at 1, 2, 8, 12, and 26 and 55 weeks to visually evaluate the surgical incision for suture retention, incision healing, erythema, and swelling. Incisions were also assessed microscopically at 1, 2, and 8 weeks for necrosis, inflammation, hemorrhage, and fibroplasia. The results indicated that incisions closed with either Vicryl or Prolene suture materials were more likely to exhibit more erythema or incomplete healing compared with those closed with Monocryl or Monocryl-Plus. The surgical implantation of a transmitter in the coelomic cavity did not significantly affect the response variables among the four suture materials. Monocryl or Monocryl-Plus were equally effective and superior to other suture materials used for closing surgical incisions in Siberian Sturgeon or closely related species of sturgeon. Furthermore, Monocryl or Monocryl-Plus may decrease the risk of transmitter expulsion through the incision, as surgical wounds appear to heal faster and exhibit less erythema compared with those closed with Vicryl.

  20. Watershed-scale modeling of streamflow change in incised montane meadows

    Science.gov (United States)

    Essaid, Hedeff I.; Hill, Barry R.

    2014-01-01

    Land use practices have caused stream channel incision and water table decline in many montane meadows of the Western United States. Incision changes the magnitude and timing of streamflow in water supply source watersheds, a concern to resource managers and downstream water users. The hydrology of montane meadows under natural and incised conditions was investigated using watershed simulation for a range of hydrologic conditions. The results illustrate the interdependence between: watershed and meadow hydrology; bedrock and meadow aquifers; and surface and groundwater flow through the meadow for the modeled scenarios. During the wet season, stream incision resulted in less overland flow and interflow and more meadow recharge causing a net decrease in streamflow and increase in groundwater storage relative to natural meadow conditions. During the dry season, incision resulted in less meadow evapotranspiration and more groundwater discharge to the stream causing a net increase in streamflow and a decrease in groundwater storage relative to natural meadow conditions. In general, for a given meadow setting, the magnitude of change in summer streamflow and long-term change in watershed groundwater storage due to incision will depend on the combined effect of: reduced evapotranspiration in the eroded meadow; induced groundwater recharge; replenishment of dry season groundwater storage depletion in meadow and bedrock aquifers by precipitation during wet years; and groundwater storage depletion that is not replenished by precipitation during wet years.

  1. Dynamic topographical pattern classification of multichannel prefrontal NIRS signals

    Science.gov (United States)

    Schudlo, Larissa C.; Power, Sarah D.; Chau, Tom

    2013-08-01

    Objective. Near-infrared spectroscopy (NIRS) is an optical imaging technique that has recently been considered for brain-computer interface (BCI) applications. To date, NIRS-BCI studies have primarily made use of temporal features of brain activity, derived from the time-course of optical signals measured from discrete locations, to differentiate mental states. However, functional brain imaging studies have indicated that the spatial distribution of haemodynamic activity is also rich in information. Thus, the progression of a response over both time and space may be valuable to brain state classification. In this paper, we investigate the implication of including spatiotemporal features in the single-trial classification of haemodynamic events for a two-class problem by exploiting this information from dynamic NIR topograms. Approach. The value of spatiotemporal information was explored through a comparative analysis of four different classification schemes performed on multichannel NIRS data collected from the prefrontal cortex during a mental arithmetic activation task and rest. Employing a linear discriminant classifier, data were analysed using spatiotemporal features, temporal features, and a collective pool of spatiotemporal and temporal features. We also considered a majority vote combination of three classifiers; each established using one of the above feature sets. Lastly, two separate task durations (20 and 10 s) were considered for feature extraction. Main results. With features from the longer task interval, the highest overall classification accuracy was achieved using the majority voting classifier (76.1 ± 8.4%), which was greater than the accuracy obtained using temporal features alone (73.5 ± 8.5%) (F3,144 = 7.04, p = 0.0002). While results from the shorter task duration were lower overall, the classifier employing only spatiotemporal features (with an average accuracy of 67.9 ± 9.3%) achieved a higher average accuracy than the rate obtained

  2. Laparoscopic repair of a Morgagni diaphragmatic hernia in a child, using a trans-sternal technique

    Directory of Open Access Journals (Sweden)

    Shah Amar

    2005-01-01

    Full Text Available Laparoscopic repair of Morgagni hernia has been described in adults and children. In the published reports, the crux of the repair consists of suturing the posterior part of the diaphragmatic defect to the undersurface of the sternum or the posterior rectus sheath. The tissue on the undersurface of the sternum is variable is in its nature and may be inadequate for suturing, hence compromising the strength of the repair. A technique that circumvents this problem and offers a strong anatomical repair is described. A Morgagni hernia was diagnosed in a 2-year-old girl with trisomy 21, who presented with recurrent chest infections. She underwent laparoscopic repair of the hernia using three ports. The tissue on the undersurface of the sternum was inadequate for a conventional repair. The procedure was modified as follows: a small transverse incision was made over the lower end of the sternum. Three nonabsorbable mattress sutures were inserted through the sternum, the anterior edge of the diaphragmatic defect, and back through the sternum and tied with extracorporeal knots. The child was discharged home on the second postoperative day. At 6-month follow up, the child was asymptomatic, and had been infection free. A chest radiograph was normal. This is a simple, novel, noninvasive method, which offers a secure anatomical repair and it is not dependent on the adequacy of the tissue on the undersurface of the sternum.

  3. Two sides of the same coin: TFIIH complexes in transcription and DNA repair.

    Science.gov (United States)

    Zhovmer, Alexander; Oksenych, Valentyn; Coin, Frédéric

    2010-04-13

    TFIIH is organized into a seven-subunit core associated with a three-subunit Cdk-activating kinase (CAK) module. TFIIH has roles in both transcription initiation and DNA repair. During the last 15 years, several studies have been conducted to identify the composition of the TFIIH complex involved in DNA repair. Recently, a new technique combining chromatin immunoprecipitation and western blotting resolved the hidden nature of the TFIIH complex participating in DNA repair. Following the recruitment of TFIIH to the damaged site, the CAK module is released from the core TFIIH, and the core subsequently associates with DNA repair factors. The release of the CAK is specifically driven by the recruitment of the DNA repair factor XPA and is required to promote the incision/excision of the damaged DNA. Once the DNA lesions have been repaired, the CAK module returns to the core TFIIH on the chromatin, together with the release of the repair factors. These data highlight the dynamic composition of a fundamental cellular factor that adapts its subunit composition to the cell needs.

  4. Valve Repair or Replacement

    Science.gov (United States)

    ... Replacement Menu Topics Topics FAQs Valve Repair or Replacement Heart valves play a key role in this ... leaflets with a tissue patch. What is valve replacement? Severe valve damage means the valve must be ...

  5. INTERNAL REPAIR OF PIPELINES

    Energy Technology Data Exchange (ETDEWEB)

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; Nancy Porter; Mike Sullivan; Chris Neary

    2004-04-12

    The two broad categories of deposited weld metal repair and fiber-reinforced composite liner repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repair and for fiber-reinforced composite liner repair. Evaluation trials have been conducted using a modified fiber-reinforced composite liner provided by RolaTube and pipe sections without liners. All pipe section specimens failed in areas of simulated damage. Pipe sections containing fiber-reinforced composite liners failed at pressures marginally greater than the pipe sections without liners. The next step is to evaluate a liner material with a modulus of elasticity approximately 95% of the modulus of elasticity for steel. Preliminary welding parameters were developed for deposited weld metal repair in preparation of the receipt of Pacific Gas & Electric's internal pipeline welding repair system (that was designed specifically for 559 mm (22 in.) diameter pipe) and the receipt of 559 mm (22 in.) pipe sections from Panhandle Eastern. The next steps are to transfer welding parameters to the PG&E system and to pressure test repaired pipe sections to failure. A survey of pipeline operators was conducted to better understand the needs and performance requirements of the natural gas transmission industry regarding internal repair. Completed surveys contained the following principal conclusions: (1) Use of internal weld repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling (HDD) when a new bore must be created

  6. Phosphate steering by Flap Endonuclease 1 promotes 5′-flap specificity and incision to prevent genome instability

    KAUST Repository

    Tsutakawa, Susan E.

    2017-06-27

    DNA replication and repair enzyme Flap Endonuclease 1 (FEN1) is vital for genome integrity, and FEN1 mutations arise in multiple cancers. FEN1 precisely cleaves single-stranded (ss) 5\\'-flaps one nucleotide into duplex (ds) DNA. Yet, how FEN1 selects for but does not incise the ss 5\\'-flap was enigmatic. Here we combine crystallographic, biochemical and genetic analyses to show that two dsDNA binding sites set the 5\\'polarity and to reveal unexpected control of the DNA phosphodiester backbone by electrostatic interactions. Via phosphate steering\\', basic residues energetically steer an inverted ss 5\\'-flap through a gateway over FEN1\\'s active site and shift dsDNA for catalysis. Mutations of these residues cause an 18,000-fold reduction in catalytic rate in vitro and large-scale trinucleotide (GAA) repeat expansions in vivo, implying failed phosphate-steering promotes an unanticipated lagging-strand template-switch mechanism during replication. Thus, phosphate steering is an unappreciated FEN1 function that enforces 5\\'-flap specificity and catalysis, preventing genomic instability.

  7. No difference in incidence of port-site hernia and chronic pain after single-incision laparoscopic cholecystectomy versus conventional laparoscopic cholecystectomy

    DEFF Research Database (Denmark)

    Christoffersen, Mette W; Brandt, Erik; Oehlenschläger, Jacob

    2015-01-01

    and matched 1:2 with patients subjected to CLC using pre-defined criteria. Follow-up data were obtained from the Danish National Patient Registry, mailed patient questionnaires, and clinical examination. A port-site hernia was defined as a repair for a port-site hernia or clinical hernia located at one......BACKGROUND: Conventional laparoscopic cholecystectomy (CLC) is regarded as the gold standard for cholecystectomy. However, single-incision laparoscopic cholecystectomy (SLC) has been suggested to replace CLC. This study aimed at comparing long-term incidences of port-site hernia and chronic pain...... after SLC versus CLC. METHODS: We conducted a matched cohort study based on prospective data (Jan 1, 2009-June 1, 2011) from the Danish Cholecystectomy Database with perioperative information and clinical follow-up. Consecutive patients undergoing elective SLC during the study period were included...

  8. Celebrating DNA's Repair Crew.

    Science.gov (United States)

    Kunkel, Thomas A

    2015-12-03

    This year, the Nobel Prize in Chemistry has been awarded to Tomas Lindahl, Aziz Sancar, and Paul Modrich for their seminal studies of the mechanisms by which cells from bacteria to man repair DNA damage that is generated by normal cellular metabolism and stress from the environment. These studies beautifully illustrate the remarkable power of DNA repair to influence life from evolution through disease susceptibility. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Human brain activity with functional NIR optical imager

    Science.gov (United States)

    Luo, Qingming

    2001-08-01

    In this paper we reviewed the applications of functional near infrared optical imager in human brain activity. Optical imaging results of brain activity, including memory for new association, emotional thinking, mental arithmetic, pattern recognition ' where's Waldo?, occipital cortex in visual stimulation, and motor cortex in finger tapping, are demonstrated. It is shown that the NIR optical method opens up new fields of study of the human population, in adults under conditions of simulated or real stress that may have important effects upon functional performance. It makes practical and affordable for large populations the complex technology of measuring brain function. It is portable and low cost. In cognitive tasks subjects could report orally. The temporal resolution could be millisecond or less in theory. NIR method will have good prospects in exploring human brain secret.

  10. FT-NIR: A Tool for Process Monitoring and More.

    Science.gov (United States)

    Martoccia, Domenico; Lutz, Holger; Cohen, Yvan; Jerphagnon, Thomas; Jenelten, Urban

    2018-03-30

    With ever-increasing pressure to optimize product quality, to reduce cost and to safely increase production output from existing assets, all combined with regular changes in terms of feedstock and operational targets, process monitoring with traditional instruments reaches its limits. One promising answer to these challenges is in-line, real time process analysis with spectroscopic instruments, and above all Fourier-Transform Near Infrared spectroscopy (FT-NIR). Its potential to afford decreased batch cycle times, higher yields, reduced rework and minimized batch variance is presented and application examples in the field of fine chemicals are given. We demonstrate that FT-NIR can be an efficient tool for improved process monitoring and optimization, effective process design and advanced process control.

  11. Diagnosis method of cucumber downy mildew with NIR hyperspectral imaging

    Science.gov (United States)

    Tian, Youwen; Li, Tianlai; Zhang, Lin; Zhang, Xiaodong

    2011-11-01

    This study was carried out to develop a hyperspectral imaging system in the near infrared (NIR) region (900-1700 nm) to diagnose cucumber downy mildew. Hyperspectral images were acquired from each diseased cucumber leaf samples with downy mildew and then their spectral data were extracted. Spectral data were analyzed using principal component analysis (PCA) to reduce the high dimensionality of the data and for selecting some important wavelengths. Out of 256 wavelengths, only two wavelengths (1426 and 1626nm) of first PC were selected as the optimum wavelengths for the diagnosis of cucumber downy mildew. The data analysis showed that it is possible to diagnose cucumber downy mildew with few numbers of wavelengths on the basis of their statistical image features and histogram features. The results revealed the potentiality of NIR hyperspectral imaging as an objective and non-destructive method for the authentication and diagnosis of cucumber downy mildew.

  12. NIR FRET Fluorophores for Use as an Implantable Glucose Biosensor

    Directory of Open Access Journals (Sweden)

    Majed DWEIK

    2008-12-01

    Full Text Available Development of an in vivo optical sensor requires the utilization of Near Infra Red (NIR fluorophores due to their ability to operate within the biological tissue window. Alexa Fluor 750 (AF750 and Alexa Fluor 680 (AF680 were examined as potential NIR fluorophores for an in vivo fluorescence resonance energy transfer (FRET glucose biosensor. AF680 and AF750 found to be a FRET pair and percent energy transfer was calculated. Next, the tested dye pair was utilized in a competitive binding assay in order to detect glucose. Concanavalin A (Con A and dextran have binding affinity, but in the presence of glucose, glucose displaces dextran due to its higher affinity to Con A than dextran. Finally, the percent signal transfer through porcine skin was examined. The results showed with approximately 4.0 mm porcine skin thickness, 1.98 % of the fluorescence was transmitted and captured by the detector.

  13. Outcomes of Phacoemulsification Using Different Size of Clear Corneal Incision in Eyes with Previous Radial Keratotomy.

    Directory of Open Access Journals (Sweden)

    Jing Shang Zhang

    Full Text Available To evaluate visual outcomes and complications after phacoemulsification in eyes with cataract and previous radial keratotomy (RK cuts using different sizes of clear corneal incisions.The study was a retrospective study. Thirty eyes with cataract and previous RK underwent phacoemulsification and intraocular lens (IOL implantation. Among them 7 eyes had 8 RK cuts, 13 eyes had 12 RK cuts, and 10 eyes had 16 RK cuts. Phacoemulsification and IOL implantation were performed through a 2.0-3.2 mm clear corneal incision by a single surgeon. In the 8 RK cuts group, 3.2 mm clear corneal incisions were used in 4 eyes, and 3.0 mm clear corneal incisions were used in 3 eyes. In the 12 RK cuts group, 3.2 mm clear corneal incisions were used in 6 eyes, and 2.2 mm clear corneal incisions were used in 7 eyes. In the 16 RK cuts group, 3.2 mm clear corneal incisions were used in 5 eyes, and 2.0 mm clear corneal incisions were used in 5 eyes. Patients were followed up 1 day, 1 week, 1 month, 3 months, 6 months, 1 year, 2 years, and 3 years postoperatively and were examined for the dehiscence of RK cuts during or after the surgery, post-operative best-corrected visual acuity (BCVA, corneal astigmatism, corneal endothelial cell density and complications.Successful phacoemulsification with IOL implantation was performed in all eyes. No wound dehiscence was noted in any eyes with 8 or 12 RK cuts. Wound dehiscence was noted in 2 eyes with 16 RK cuts. The dehiscence of RK cuts was closed successfully by injecting an air bubble with or without viscoelastic agent into the anterior chamber at the end of surgery. During the follow-up, the cuts were well apposed in all eyes, and no new dehiscence of RK cuts was noted. At the last follow-up, mean BCVA (0.2 ± 0.18 logMAR was better than preoperative BCVA(0.45±0.19 logMAR (P < 0.001. There was no significant difference between the long-term preoperative and postoperative mean corneal astigmatism (P = 0.3. However, there was a

  14. Prospective randomized comparison of the safety, efficacy, and cosmetic outcome associated with mini-transverse and mini-longitudinal radical prostatectomy incisions

    Directory of Open Access Journals (Sweden)

    Bruce R Kava

    2010-01-01

    Conclusions : Seven-centimeter transverse and longitudinal mini-incisions offer alternatives to the standard ORP incision, and to minimally invasive approaches. Both incisions are safe, associated with little postoperative pain, and a short postoperative LOS. Both incisions provide highly satisfactory cosmesis for the patient.

  15. [EMD Time-Frequency Analysis of Raman Spectrum and NIR].

    Science.gov (United States)

    Zhao, Xiao-yu; Fang, Yi-ming; Tan, Feng; Tong, Liang; Zhai, Zhe

    2016-02-01

    This paper analyzes the Raman spectrum and Near Infrared Spectrum (NIR) with time-frequency method. The empirical mode decomposition spectrum becomes intrinsic mode functions, which the proportion calculation reveals the Raman spectral energy is uniform distributed in each component, while the NIR's low order intrinsic mode functions only undertakes fewer primary spectroscopic effective information. Both the real spectrum and numerical experiments show that the empirical mode decomposition (EMD) regard Raman spectrum as the amplitude-modulated signal, which possessed with high frequency adsorption property; and EMD regards NIR as the frequency-modulated signal, which could be preferably realized high frequency narrow-band demodulation during first-order intrinsic mode functions. The first-order intrinsic mode functions Hilbert transform reveals that during the period of empirical mode decomposes Raman spectrum, modal aliasing happened. Through further analysis of corn leaf's NIR in time-frequency domain, after EMD, the first and second orders components of low energy are cut off, and reconstruct spectral signal by using the remaining intrinsic mode functions, the root-mean-square error is 1.001 1, and the correlation coefficient is 0.981 3, both of these two indexes indicated higher accuracy in re-construction; the decomposition trend term indicates the absorbency is ascending along with the decreasing to wave length in the near-infrared light wave band; and the Hilbert transform of characteristic modal component displays, 657 cm⁻¹ is the specific frequency by the corn leaf stress spectrum, which could be regarded as characteristic frequency for identification.

  16. NIR observations of V404 Cyg with PANIC

    Science.gov (United States)

    Shaw, A. W.; Knigge, C.; Meisenheimer, K.; Ibanez, J. M.

    2015-07-01

    We report on NIR photometry of the black hole X-ray transient, V404 Cyg during its current outburst (GCN #17929). The source was observed between 27 Jun 22:47 UT - 29 Jun UT 02:28 with the PANoramic Near Infrared Camera (PANIC) on the 2.2m telescope at the Centro Astron & oacute;mico Hispano-Alem & aacute;n (CAHA) on Calar Alto, Spain.

  17. Relationship between muscle oxygenation by NIRS and blood lactate

    Energy Technology Data Exchange (ETDEWEB)

    Xu Guodong [School of Physical Education, Jianghan University, Hubei Wuhan 430056 (China); Mao Zongzhen; Ye Yanjie; Lv Kunru, E-mail: xguodong@wipe.edu.cn [School of Health Sciences, Wuhan Institute of Physical Education, Hubei Wuhan 430079 (China)

    2011-01-01

    The aim of the study was to investigate the relationship of muscle oxygenation in term of oxy-hemoglobin concentration change ({Delta}HbO{sub 2}) by NIRS and blood lactate (BLA) in local skeletal muscle and evaluate the capability of NIRS in the research of exercise physiology Twenty-three athlete in the national fin-swimming team took the increasing load training on the power bicycle while their {Delta}HbO{sub 2} and BLA were simultaneously recorded. The initial powers used in the training were set as 100 w for males and 40 w for females. During the experiment, the power kept constant for 3 min before each abrupt increment of 30 w until the limit of the athlete's capability. Statistical analysis and data visualization were performed. Following the increasing load training, {Delta}HbO{sub 2} step-likely increased in the phase of aerobic metabolism but linearly decreased in the phase of anaerobic metabolism. The variation tendency of BLA was the same as {Delta}HbO{sub 2} and the concurrency of crucial turning points between {Delta}HbO{sub 2} and BLA was revealed. This relationship between {Delta}HbO{sub 2} and BLA presented in the increasing load training suggested that {Delta}HbO{sub 2} might be capable for taking the place of the invasively measured parameter BLA. Considering that {Delta}HbO{sub 2} can be noninvasively measured by NIRS, {Delta}HbO{sub 2} has the potential in the evaluation of athletes' physiological function and training effect on the athletes and accordingly NIRS can be well used in this field.

  18. Relationship between muscle oxygenation by NIRS and blood lactate

    International Nuclear Information System (INIS)

    Xu Guodong; Mao Zongzhen; Ye Yanjie; Lv Kunru

    2011-01-01

    The aim of the study was to investigate the relationship of muscle oxygenation in term of oxy-hemoglobin concentration change (ΔHbO 2 ) by NIRS and blood lactate (BLA) in local skeletal muscle and evaluate the capability of NIRS in the research of exercise physiology Twenty-three athlete in the national fin-swimming team took the increasing load training on the power bicycle while their ΔHbO 2 and BLA were simultaneously recorded. The initial powers used in the training were set as 100 w for males and 40 w for females. During the experiment, the power kept constant for 3 min before each abrupt increment of 30 w until the limit of the athlete's capability. Statistical analysis and data visualization were performed. Following the increasing load training, ΔHbO 2 step-likely increased in the phase of aerobic metabolism but linearly decreased in the phase of anaerobic metabolism. The variation tendency of BLA was the same as ΔHbO 2 and the concurrency of crucial turning points between ΔHbO 2 and BLA was revealed. This relationship between ΔHbO 2 and BLA presented in the increasing load training suggested that ΔHbO 2 might be capable for taking the place of the invasively measured parameter BLA. Considering that ΔHbO 2 can be noninvasively measured by NIRS, ΔHbO 2 has the potential in the evaluation of athletes' physiological function and training effect on the athletes and accordingly NIRS can be well used in this field.

  19. Greenhouse with a CPV system based on NIR reflecting lamellae

    OpenAIRE

    Sonneveld, P.J.; Swinkels, G.L.A.M.; Tuijl, van, B.A.J.; Janssen, H.J.J.; Bot, G.P.A.

    2012-01-01

    In previous research a new type of greenhouse with an integrated concentrated photovoltaic system (CPV) was developed based on a circular covering geometry and an integrated filter for reflecting the near infrared radiation (NIR) of the greenhouse and exploiting this radiation in a solar energy system. The performance of the system was promising. In this study further optimalisation of the CPV system is made to avoid the large construction for solar tracing and the high investment. Hereto all...

  20. The application of near infrared spectroscopy (NIR technique for

    Directory of Open Access Journals (Sweden)

    Sandor Barabassy

    2001-06-01

    Full Text Available The production of cow’s milk in Hungary fluctuates by 15-20 % annualy. Surplus milk is dried into powder and can also be converted to modified milk powders using techniques such as ultra filtration. From approximetely 20.000 tonnes, of all milk powder types, 3.000 tonnes, is converted using ultra filtration technology. Multivariable near infrared (NIR calibration was performed on powder mixtures of whole milk, skimmed milk, whey, retenate (protein concentrate and lactose for rapid fat, protein, lactose, water and ash content determination. More than 150 samples were prepared and measured in two NIRS labs (Scottish Agriculture College – SAC – Aberdeen and University of Horticulture and Food Science - UHFS – Budapest. The results obtained from the same samples were compared. The aims of the study were: 1. Rapid quantitative and qualitative determination of mixtures of milk powder products using NIR technique. 2. Comparison of the results achieved in Aberdeen (SAC and Budapest (UHFS institutes. The mass per cent varied between 0.0-2.8% for fat, 0.0-80% for protein, 6.6-100 % for lactose, 0.0-5.0 % for water and 0.0-8.0 % for ash. High correlation coefficients (0.97-0.99 were found for all five components.

  1. UV-VIS-NIR spectroscopy and microscopy of heterogeneous catalysts.

    Science.gov (United States)

    Schoonheydt, Robert A

    2010-12-01

    This critical review article discusses the characterization of heterogeneous catalysts by UV-VIS-NIR spectroscopy and microscopy with special emphasis on transition metal ion containing catalysts. A review is given of the transitions, that can be observed in the UV-VIS-NIR region and the peculiarities of catalytic solids that have to be taken into account. This is followed by a short discussion of the techniques that have been developed over the years: diffuse reflectance spectroscopy, UV-VIS microscopy, in situ or operando spectroscopy, the combination of UV-VIS spectroscopy with other spectroscopic techniques, with chemometrics and with quantum chemistry. In the third part of this paper four successes of UV-VIS-NIR spectroscopy and microscopy are discussed; (1) coordination of transition metal ions to surface oxygens; (2) quantitative determination of the oxidation states of transition metal ions; (3) characterization of active sites and (4) study of the distribution of transition metal ions and carbocations in catalytic bodies, particles and crystals (104 references).

  2. GSH-Activated NIR Fluorescent Prodrug for Podophyllotoxin Delivery.

    Science.gov (United States)

    Liu, Yajing; Zhu, Shaojia; Gu, Kaizhi; Guo, Zhiqian; Huang, Xiaoyu; Wang, Mingwei; Amin, Hesham M; Zhu, Weihong; Shi, Ping

    2017-09-06

    Theranostic prodrug therapy enables the targeted delivery of anticancer drugs with minimized adverse effects and real-time in situ monitoring of activation of the prodrugs. In this work, we report the synthesis and biological assessment of the near-infrared (NIR) prodrug DCM-S-PPT and its amphiphilic copolymer (mPEG-DSPE)-encapsulated nanoparticles. DCM-S-PPT is composed of podophyllotoxin (PPT) as the anticancer moiety and a dicyanomethylene-4H-pyran (DCM) derivative as the NIR fluorescent reporter, which are linked by a thiol-specific cleavable disulfide bond. In vitro experiments indicated that DCM-S-PPT has low cytotoxicity and that glutathione (GSH) can activate DCM-S-PPT resulting in PPT release and a concomitant significant enhancement in NIR fluorescence at 665 nm. After being intravenously injected into tumor-bearing nude mice, DCM-S-PPT exhibited excellent tumor-activated performance. Furthermore, we have demonstrated that mPEG-DSPE as a nanocarrier loaded with DCM-S-PPT (mPEG-DSPE/DCM-S-PPT) showed even greater tumor-targeting performance than DCM-S-PPT on account of the enhanced permeability and retention effect. Its tumor-targeting ability and specific drug release in tumors make DCM-S-PPT a promising prodrug that could provide a significant strategy for theranostic drug delivery systems.

  3. Characterization of Mind Wandering using fNIRS

    Directory of Open Access Journals (Sweden)

    Gautier eDurantin

    2015-03-01

    Full Text Available Assessing whether someone is attending to a task has become importantfor educational and professional applications. Such attentional drifts are usually termed mind wandering. The purpose of the current study is to test to what extent a recent neural imaging modality can be used to detect mind wandering episodes. Functional near infra-red spectroscopy is a non-invasive neuro-imaging technique that has never been studied so far to measure mind wandering. The Sustained Attention to Response Task was used to assess when subjects attention leaves a primary task. 16-channel fNIRS data were collected over frontal cortices. We observed significant activations over the medial prefrontal cortex during mind wandering, a brain region associated with the default mode network. fNIRS data were used to classify mind wandering data above chance level. In line with previous brain-imaging studies of mind wandering, our results confirm the ability of fNIRS to detect Default Network activations in the context of mind wandering.

  4. Principle and application of portable NIR tea drinks analyzer

    Science.gov (United States)

    Jiang, Liyi; Chen, Huacai; Liu, Fuli

    2009-11-01

    Tea polyphenols (Tp) and free amino acids (Aa) are the most important quality materials in tea drinks. Due to the high number of samples to be analyzed, new analytical techniques providing fast and reliable data about the quality are essential. Therefore, a portable near-infrared spectroscopy (NIR) analyzer was developed for real-time, continuous and quantitative determination of Tp and Aa in tea drinks. The portable NIR tea drinks analyzer is composed of a lamphouse, a temperature-controlled sample chamber, an optical fiber and an InGaAs array mini grating spectrometer. The analyzer is compact, lightweight and robust with no movable elements. The software with the functions of spectrum acquisition, model establishment, method selection and real-time analysis was also developed for the analyzer. Using partial least squares (PLS) regression, the calibration models for the quantification of Tp and Aa were established with reference to the GB methods (the national standard methods). The values of root mean square error of cross validation (RMSECV) of the models for Tp and Aa calibration were 0.059 mg/mL, 0.005 mg/mL, the values of the correlation coefficients (R2) were 0.99 and 0.98 respectively. The relative standard deviation (RSD) of ten repetitive testing were 3.17% and 4.15%. It suggested that the portable NIR tea drinks analyzer could be a fast and reliable alternative for tea drinks quality testing.

  5. Joint attention studies in normal and autistic children using NIRS

    Science.gov (United States)

    Chaudhary, Ujwal; Hall, Michael; Gutierrez, Anibal; Messinger, Daniel; Rey, Gustavo; Godavarty, Anuradha

    2011-03-01

    Autism is a socio-communication brain development disorder. It is marked by degeneration in the ability to respond to joint attention skill task, from as early as 12 to 18 months of age. This trait is used to distinguish autistic from nonautistic. In this study Near infrared spectroscopy (NIRS) is being applied for the first time to study the difference in activation and connectivity in the frontal cortex of typically developing (TD) and autistic children between 4-8 years of age in response to joint attention task. The optical measurements are acquired in real time from frontal cortex using Imagent (ISS Inc.) - a frequency domain based NIRS system in response to video clips which engenders a feeling of joint attention experience in the subjects. A block design consisting of 5 blocks of following sequence 30 sec joint attention clip (J), 30 sec non-joint attention clip (NJ) and 30 sec rest condition is used. Preliminary results from TD child shows difference in brain activation (in terms of oxy-hemoglobin, HbO) during joint attention interaction compared to the nonjoint interaction and rest. Similar activation study did not reveal significant differences in HbO across the stimuli in, unlike in an autistic child. Extensive studies are carried out to validate the initial observations from both brain activation as well as connectivity analysis. The result has significant implication for research in neural pathways associated with autism that can be mapped using NIRS.

  6. Near-infrared (NIR) up-conversion optogenetics

    Science.gov (United States)

    Hososhima, Shoko; Yuasa, Hideya; Ishizuka, Toru; Hoque, Mohammad Razuanul; Yamashita, Takayuki; Yamanaka, Akihiro; Sugano, Eriko; Tomita, Hiroshi; Yawo, Hiromu

    2015-11-01

    Non-invasive remote control technologies designed to manipulate neural functions have been long-awaited for the comprehensive and quantitative understanding of neuronal network in the brain as well as for the therapy of neurological disorders. Recently, it has become possible for the neuronal activity to be optically manipulated using biological photo-reactive molecules such as channelrhodopsin (ChR)-2. However, ChR2 and its relatives are mostly reactive to visible light, which does not effectively penetrate through biological tissues. In contrast, near-infrared (NIR) light (650-1450 nm) penetrates deep into the tissues because biological systems are almost transparent to light within this so-called ‘imaging window’. Here we used lanthanide nanoparticles (LNPs), composed of rare-earth elements, as luminous bodies to activate ChRs since they absorb low-energy NIR light to emit high-energy visible light (up-conversion). Here, we created a new type of optogenetic system which consists of the donor LNPs and the acceptor ChRs. The NIR laser irradiation emitted visible light from LNPs, then induced the photo-reactive responses in the near-by cells that expressed ChRs. However, there remains room for large improvements in the energy efficiency of the LNP-ChR system.

  7. The contemporary role of 1 vs. 2-stage repair for proximal hypospadias

    Science.gov (United States)

    Dason, Shawn; Wong, Nathan

    2014-01-01

    This review discusses the most commonly employed techniques in the repair of proximal hypospadias, highlighting the advantages and disadvantages of single versus staged surgical techniques. Hypospadias can have a spectrum of severity with a urethral meatus ranging from the perineum to the glans. Associated abnormalities are commonly found with proximal hypospadias and encompass a large spectrum, including ventral curvature (VC) up to 50 degrees or more, ventral skin deficiency, a flattened glans, penile torsion and penoscrotal transposition. Our contemporary understanding of hypospadiology is comprised of a foundation built by experts who have described a number of techniques and their outcomes, combined with survey data detailing practice patterns. The two largest components of hypospadias repair include repair of VC and urethroplasty. VC greater than 20 degrees is considered clinically relevant to warrant surgical correction. To repair VC, the penis is first degloved—a procedure that may reduce or remove curvature by itself in some cases. Residual curvature is then repaired with dorsal plication techniques, transection of the urethral plate, and/or ventral lengthening techniques. Urethroplasty takes the form of 1- or 2-stage repairs. One-stage options include the tubularized incised urethroplasty (TIP) or various graft or flap-based techniques. Two-stage options also include grafts or flaps, including oral mucosal and preputial skin grafting. One stage repairs are an attractive option in that they may reduce cost, hospital stay, anesthetic risks, and time to the final result. The downside is that these repairs require mastery of multiple techniques may be more complex, and—depending on technique—have higher complication rates. Two-stage repairs are preferred by the majority of surveyed hypospadiologists. The 2-stage repair is versatile and has satisfactory outcomes, but necessitates a second procedure. Given the lack of clear high-quality evidence

  8. Vitamin C deficiency in weanling guinea pigs: differential expression of oxidative stress and DNA repair in liver and brain

    DEFF Research Database (Denmark)

    Lykkesfeldt, Jens; Trueba, Gilberto Perez; Poulsen, Henrik E

    2007-01-01

    Neonates are particularly susceptible to malnutrition due to their limited reserves of micronutrients and their rapid growth. In the present study, we examined the effect of vitamin C deficiency on markers of oxidative stress in plasma, liver and brain of weanling guinea pigs. Vitamin C deficiency...... incision repair (P = 0.014) were all increased, while protein oxidation decreased (P = 0.003). The results show that the selective preservation of brain ascorbate and induction of DNA repair in vitamin C-deficient weanling guinea pigs is not sufficient to prevent oxidative damage. Vitamin C deficiency may...

  9. A Two-Dimensional Biodegradable Niobium Carbide (MXene) for Photothermal Tumor Eradication in NIR-I and NIR-II Biowindows.

    Science.gov (United States)

    Lin, Han; Gao, Shanshan; Dai, Chen; Chen, Yu; Shi, Jianlin

    2017-11-15

    Conventionally, ceramics-based materials, fabricated by high-temperature solid-phase reaction and sintering, are preferred as bone scaffolds in hard-tissue engineering because of their tunable biocompatibility and mechanical properties. However, their possible biomedical applications have rarely been considered, especially the cancer phototherapeutic applications in both the first and second near-infrared light (NIR-I and NIR-II) biowindows. In this work, we explore, for the first time as far as we know, a novel kind of 2D niobium carbide (Nb 2 C), MXene, with highly efficient in vivo photothermal ablation of mouse tumor xenografts in both NIR-I and NIR-II windows. The 2D Nb 2 C nanosheets (NSs) were fabricated by a facile and scalable two-step liquid exfoliation method combining stepwise delamination and intercalation procedures. The ultrathin, lateral-nanosized Nb 2 C NSs exhibited extraordinarily high photothermal conversion efficiency (36.4% at NIR-I and 45.65% at NIR-II), as well as high photothermal stability. The Nb 2 C NSs intrinsically feature unique enzyme-responsive biodegradability to human myeloperoxidase, low phototoxicity, and high biocompatibility. Especially, these surface-engineered Nb 2 C NSs present highly efficient in vivo photothermal ablation and eradication of tumor in both NIR-I and NIR-II biowindows. This work significantly broadens the application prospects of 2D MXenes by rationally designing their compositions and exploring related physiochemical properties, especially on phototherapy of cancer.

  10. Indocyanine green fluorescence in second near-infrared (NIR-II) window.

    Science.gov (United States)

    Starosolski, Zbigniew; Bhavane, Rohan; Ghaghada, Ketan B; Vasudevan, Sanjeev A; Kaay, Alexander; Annapragada, Ananth

    2017-01-01

    Indocyanine green (ICG), a FDA approved near infrared (NIR) fluorescent agent, is used in the clinic for a variety of applications including lymphangiography, intra-operative lymph node identification, tumor imaging, superficial vascular imaging, and marking ischemic tissues. These applications operate in the so-called "NIR-I" window (700-900 nm). Recently, imaging in the "NIR-II" window (1000-1700 nm) has attracted attention since, at longer wavelengths, photon absorption, and scattering effects by tissue components are reduced, making it possible to image deeper into the underlying tissue. Agents for NIR-II imaging are, however, still in pre-clinical development. In this study, we investigated ICG as a NIR-II dye. The absorbance and NIR-II fluorescence emission of ICG were measured in different media (PBS, plasma and ethanol) for a range of ICG concentrations. In vitro and in vivo testing were performed using a custom-built spectral NIR assembly to facilitate simultaneous imaging in NIR-I and NIR-II window. In vitro studies using ICG were performed using capillary tubes (as a simulation of blood vessels) embedded in Intralipid solution and tissue phantoms to evaluate depth of tissue penetration in NIR-I and NIR-II window. In vivo imaging using ICG was performed in nude mice to evaluate vascular visualization in the hind limb in the NIR-I and II windows. Contrast-to-noise ratios (CNR) were calculated for comparison of image quality in NIR-I and NIR-II window. ICG exhibited significant fluorescence emission in the NIR-II window and this emission (similar to the absorption profile) is substantially affected by the environment of the ICG molecules. In vivo imaging further confirmed the utility of ICG as a fluorescent dye in the NIR-II domain, with the CNR values being ~2 times those in the NIR-I window. The availability of an FDA approved imaging agent could accelerate the clinical translation of NIR-II imaging technology.

  11. Indocyanine green fluorescence in second near-infrared (NIR-II window.

    Directory of Open Access Journals (Sweden)

    Zbigniew Starosolski

    Full Text Available Indocyanine green (ICG, a FDA approved near infrared (NIR fluorescent agent, is used in the clinic for a variety of applications including lymphangiography, intra-operative lymph node identification, tumor imaging, superficial vascular imaging, and marking ischemic tissues. These applications operate in the so-called "NIR-I" window (700-900 nm. Recently, imaging in the "NIR-II" window (1000-1700 nm has attracted attention since, at longer wavelengths, photon absorption, and scattering effects by tissue components are reduced, making it possible to image deeper into the underlying tissue. Agents for NIR-II imaging are, however, still in pre-clinical development. In this study, we investigated ICG as a NIR-II dye. The absorbance and NIR-II fluorescence emission of ICG were measured in different media (PBS, plasma and ethanol for a range of ICG concentrations. In vitro and in vivo testing were performed using a custom-built spectral NIR assembly to facilitate simultaneous imaging in NIR-I and NIR-II window. In vitro studies using ICG were performed using capillary tubes (as a simulation of blood vessels embedded in Intralipid solution and tissue phantoms to evaluate depth of tissue penetration in NIR-I and NIR-II window. In vivo imaging using ICG was performed in nude mice to evaluate vascular visualization in the hind limb in the NIR-I and II windows. Contrast-to-noise ratios (CNR were calculated for comparison of image quality in NIR-I and NIR-II window. ICG exhibited significant fluorescence emission in the NIR-II window and this emission (similar to the absorption profile is substantially affected by the environment of the ICG molecules. In vivo imaging further confirmed the utility of ICG as a fluorescent dye in the NIR-II domain, with the CNR values being ~2 times those in the NIR-I window. The availability of an FDA approved imaging agent could accelerate the clinical translation of NIR-II imaging technology.

  12. A study of incisive canal using a cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-03-15

    To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70 kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. The mean length of incisive canal was 15.87 mm {+-} 2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm {+-} 0.76 and 3.89 mm {+-} 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3 {+-} 6.96 and 117.45 {+-} 7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r 0.258). This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  13. Neogene unroofing and incision of the Ethiopian Plateau constrained from apatite (U-Th)/He thermochronometry

    Science.gov (United States)

    Gani, N. D.; Van Soest, M. C.; Gani, M. R.; Tadesse, K.; Neupane, P. C.; Falster, A.

    2011-12-01

    Ethiopian Plateau in East Africa, one of the large igneous provinces, has been deeply incised by the Blue Nile River. The plateau has experienced extensive volcanisms at ~30 Ma linked to outpouring of the Afar mantle plume that accumulated average 1 km thick flood basalt. This event, along with later repetitive volcanisms in the region, has complicated (e.g., partial resetting of mineral cooling ages, abnormal geothermal gradients) the application of thermochronological modeling to constrain the Cenozoic unroofing and incision history of the plateau. In this study, we used (U-Th)/He thermochronometry of apatite grains extracted from gneissic and granitic basement rocks and overlying sandstones in a 1.2 km vertical elevation profile within the Blue Nile Canyon to partition incision in geologic time. Our apatite cooling ages are comparatively older than that of previous thermochronological studies of the area. These cooling ages show wide range and random distribution with elevation but positively correlate with effective uranium (eU) concentration of apatite minerals. Thus we chose recently developed RDAAM (Radiation Damage Accumulation and Annealing model) inverse modeling in HeFTy that was demonstrated to be appropriate for regions with complex thermal history and variable eU concentration. Initial results of RDAAM model, guided by reasonable thermal history of the plateau, show gradual cooling and thus slow incision during Early Neogene after the rapid heating of the region linked to the accumulation of thick flood basalt around 30 Ma. Importantly, these simulations predict rapid cooling, thus fast incision, during Late Neogene. This incision history of the Ethiopian Plateau interpreted from apatite thermal modeling is consistent with the previous GIS-and-geochronology-based study that showed increased incision rates around 10 Ma and 6 Ma.

  14. Oblique lateral incision and subpectoral dissection in modified Nuss procedure minimize future breast deformity.

    Science.gov (United States)

    Kimura, Hiroaki; Yasuoka, Tomoyuki; Nagao, Munetomo; Kudoh, Shin; Kobayashi, Seiichiro

    2015-05-01

    We experienced the occurrence of breast deformity in some young female patients who underwent a modified Nuss procedure before breast development. We studied the causes of and preventive measures for this complication. We classified 13 prepubescent female patients who underwent our modified Nuss procedure into three groups according to the direction of the skin incision and the dissection layer for bar insertion. Four patients who underwent transverse lateral thoracic skin incision and bar insertion through a subpectoral dissection were assigned to the T/SP group, five who underwent oblique skin incision along the rib and bar insertion through a suprapectoral dissection were assigned to the O/IP group, and four who underwent oblique skin incision and subpectoral dissection were assigned to the O/SP group. Each patient in the T/SP group underwent the operation by a different surgeon, two of whom were the authors, including the first author; the first author performed all operations in the O/IP and O/SP groups. The first author evaluated the shape of the developed breasts using the frontal- and oblique-view photographs. We also investigated the location of the lateral border of the mammary gland in seven other adolescent and adult female patients using three-dimensional computed tomography images. Lateral depression of the breast occurred in four of eight breasts with a transverse incision, and flattening of the lowermost portion of the inframammary fold occurred in six of 10 breasts with suprapectoral dissection. None of the eight breasts with an oblique incision and subpectoral dissection exhibited deformities. The lateral border of the mammary gland was on the fifth rib in five patients and on the fifth intercostal space in two patients. An oblique lateral thoracic skin incision along the sixth rib and subpectoral dissection may reduce the occurrence of breast deformity. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons

  15. Regression analysis of controllable factors of surgical incision complications in closed calcaneal fractures

    Directory of Open Access Journals (Sweden)

    Kai Wu

    2014-01-01

    Full Text Available Background: In surgeries of closed calcaneal fractures, the lateral L-shaped incision is usually adopted. Undesirable post-operative healing of the incision is a common complication. In this retrospective study, controllable risk factors of incision complications after closed calcaneal fracture surgery through a lateral L-shaped incision are discussed and the effectiveness of clinical intervention is assessed. Materials and Methods: A review of medical records was conducted of 209 patients (239 calcaneal fractures surgically treated from June 2005 to October 2012. Univariate analyses were performed of seven controllable factors that might influence complications associated with the surgical incision. Binomial multiple logistic regression analysis was performed to determine factors of statistical significance. Results: Twenty-one fractures (8.79% involved surgical incision complications, including 8 (3.35% cases of wound dehiscence, 7 (2.93% of flap margin necrosis, 5 (2.09% of hematoma, and 1 (0.42% of osteomyelitis. Five factors were statistically significant : t0 he time from injury to surgery, operative duration, post-operative drainage, retraction of skin flap, bone grafting, and patients′ smoking habits. The results of multivariate analyses showed that surgeries performed within 7 days after fracture, operative time > 1.5 h, no drainage after surgery, static skin distraction, and patient smoking were risk factors for calcaneal incision complications. The post-operative duration of antibiotics and bone grafting made no significant difference. Conclusion: Complications after calcaneal surgeries may be reduced by postponing the surgery at least 7 days after fracture, shortening the time in surgery, implementing post-operative drainage, retracting skin flaps gently and for as short a time as possible, and prohibiting smoking.

  16. Surgical repair of incisional ventral hernias: tension-free technique using prosthetic materials (expanded polytetrafluoroethylene Gore-Tex Dual Mesh).

    Science.gov (United States)

    Chrysos, E; Athanasakis, E; Saridaki, Z; Kafetzakis, A; Dimitriadou, D; Koutsoumpas, V; Chalkiadakis, G; Xynos, E; Zoras, O

    2000-07-01

    Repairing an incisional ventral hernia is a major challenge for a surgeon. The high recurrence rates observed during hernia repair by tissue approximation led to development of tension-free procedures by using prosthetic materials. The purpose of this study is to report the results of a tension-free repair technique using expanded polytetrafluoroethylene Gore-Tex Dual Mesh (Gore-Tex Soft Tissue Patch, W.L. Gore and Associates Inc, Flagstaff, AZ) in patients with primary or recurrent incisional ventral hernias. Over 3 years, 52 patients with incisional hernias have undergone this procedure in our clinic. Fourteen of them had recurrent hernias which had been primarily repaired by Mayo hernioplasty. Six of our patients had irreducible hernias preoperatively. Twenty-five patients had hernias on midline incisions, and the rest of them had hernias on transverse abdominal incisions. The median patient age was 65 years, and all were operated on under general anesthesia. The majority of the patients had 4 to 6 days of hospitalization. A subcutaneous seroma developed in eight patients. They all were treated by multiple paracentesis. Four of our patients experienced wound infection and were treated by mesh removal. None of the patients presented with cardiovascular or pulmonary complications. During the follow-up period, no other hernia recurrence, except the cases with mesh removal, has been noticed. The tension-free incisional hernia repair using expanded polytetrafluoroethylene mesh is, to our experience, a safe and easy procedure with no major morbidity or recurrence.

  17. Evaluation of a new range of light-activated surgical adhesives for tissue repair in a porcine model

    Science.gov (United States)

    Riley, Jill N.; Hodges, Diane E.; March, Keith L.; McNally-Heintzelman, Karen M.

    2001-05-01

    An in vitro study was conducted to determine the feasibility of using a new range of light-activated surgical adhesives for incision repair in a wide range of tissue types. Biodegradable polymer membranes of controlled porosity were fabricated with poly(L-lactic-co-glycolic acid) (PLGA) and salt particles using a solvent-casting and particulate- leaching technique. The porous membranes were doped with protein solder composed of 50%(w/v) bovine serum albumin solder and 0.5 mg/ml indocyanine green (ICG) dye mixed in deionized water. Tissue incisions were repaired using the surgical adhesive in conjunction with an 805-nm diode laser. Nine organs were tested ranging from skin to liver to the small intestine, as well as the coronary, pulmonary, carotid, femoral and splenetic arteries. Acute breaking strengths were measured and the data were analyzed by Student's T-test. Repairs formed on the small intestine were most successful followed by spleen, atrium, kidney, muscle and skin. The strongest vascular repairs were achieved in the carotid artery and femoral artery. The new surgical adhesive could possibly be used as a simple and effective method to stop bleeding and repair tissue quickly in an emergency situation, or as a substitute to mechanical staples or sutures in many clinical applications.

  18. A pregnant woman with a surgical site infection after mesh repair of an abdominal wall incisional hernia: a case report.

    Science.gov (United States)

    Ozaki, Kana; Tanimura, Kenji; Ebina, Yasuhiko; Kanemitsu, Kiyonori; Yamada, Hideto

    2017-03-11

    Surgical meshes are widely used in incisional hernia repair. However, there are no reports of pregnancies complicated by infection of surgical meshes used for hernia repair. This is the first case report of a pregnant woman who experienced surgical site infection associated with surgical mesh used for repair of an abdominal wall incisional hernia. We report a case of a 41-year-old pregnant Japanese woman with surgical site infection after mesh repair of an abdominal wall incisional hernia. She was diagnosed with an abdominal wall incisional hernia at 3 months after her third cesarean section, and she underwent an operation of hernia repair with use of monofilament polypropylene mesh 7 months after the third cesarean section. However, a surgical site infection associated with surgical mesh occurred. During antibiotic treatment, she was found to be pregnant. She was referred to our hospital at 13 weeks and 2 days of gestation. The surgeons removed the infected mesh at 16 weeks and 3 days of gestation. Neither the hernia nor infection at the surgical site recurred throughout pregnancy. We planned a cesarean section using a transverse uterine fundal incision method with an upper abdominal incision. The patient delivered a 2478-g healthy female infant. The present report shows that removal of mesh can safely control surgical site infection during pregnancy.

  19. REPAIR OF LARGE SKULL BASE DEFECT FOLLOWING EXCISION OF BASALOID SQUAMOUS CELL CARCINOMA OF MAXILLO - ETHMOID REGION : A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Monoj Mukherjee

    2015-02-01

    Full Text Available AIM: To present a case of basaloid squamous cell carcinoma of maxillo - ethmoid region with intracranial extradural extention and its surgical management including repair of the skull base defect. MATERIAL : A 30 year female presented with progressive bilateral nasal obstruction, facial deformity for 5 years duration. She developed blindness in last 6 months. Recent CT s can showed large heterogeneous enhancing soft tissue mass in right maxillary sinus, nasal cavity and right ethmoid sinus invading the skull base . INTERVENTION : She underwent excision of the mass by modified weber ferguson incision and repair of skull base defect with temporalis muscle flap. Skin defect over the face and nose was repaired by median forehead flap. RESULT : There was total tumor clearance and no CSF leakage following surgery. CONCLUSION : Sinonasal malignancy with intracranial extradural extenti on is not a contraindication for successful surgical management. Resultant skull base defect can be repaired by a temporalis muscle flap to prevent CSF leak and intracranial infection

  20. Augmented Repair of Degenerative Tears of Tendo Achilles Using Peroneus Brevis Tendon: Early Results

    Directory of Open Access Journals (Sweden)

    Tawari Akhil A

    2013-03-01

    Full Text Available Reconstruction of degenerated ruptures of the tendoachilles is a challenge. Ruptured tendons and the remaining tendon ends are abnormal. A number of methods have been described in literature reconstruct the tendoachilles, but with variable results. We used peroneus brevis tendon in 20 patients to augment the repair of degenerated tendoachilles tears by creating a dynamic loop as described by Teuffer et al. All patients were followed up for atleast 18 months. At the last postoperative visit, 18 out of 20 patients were able to do a toe raise. Eighty-five per cent of patients had excellent or good results and 15% had fair or poor results using modified Rupp scoring. Advantages offered by this procedure are the use of a single incision and mini incision and use of a dispensable tendon such as the peroneus brevis without entirely depending on the damaged tendon for healing.

  1. Factors that influence telomeric oxidative base damage and repair by DNA glycosylase OGG1

    DEFF Research Database (Denmark)

    Rhee, David B; Ghosh, Avik; Lu, Jian

    2011-01-01

    Telomeres are nucleoprotein complexes at the ends of linear chromosomes in eukaryotes, and are essential in preventing chromosome termini from being recognized as broken DNA ends. Telomere shortening has been linked to cellular senescence and human aging, with oxidative stress as a major...... contributing factor. 7,8-Dihydro-8-oxogaunine (8-oxodG) is one of the most abundant oxidative guanine lesions, and 8-oxoguanine DNA glycosylase (OGG1) is involved in its removal. In this study, we examined if telomeric DNA is particularly susceptible to oxidative base damage and if telomere-specific factors...... affect the incision of oxidized guanines by OGG1. We demonstrated that telomeric TTAGGG repeats were more prone to oxidative base damage and repaired less efficiently than non-telomeric TG repeats in vivo. We also showed that the 8-oxodG-incision activity of OGG1 is similar in telomeric and non...

  2. [A modified Onizuka cheiloplasty for repairing the unilateral cleft lip].

    Science.gov (United States)

    Zhang, Bin; Wang, Chao; Liu, Qiang; Li, Zengjian; Xu, Xianyi

    2011-08-01

    To explore the surgical technique of a modified Onizuka cheiloplasty for repairing the unilateral cleft lip. 24 patients with unilateral cleft lip were repaired by modified Onizuka cheiloplasty. The rotation flap ended at the midpoint of nasal columella crease. A small triangle skin flap was formed above the vermilion border of the advancement flap. The small triangle flap was inserted to the medial side after the Cupid's bow was built. The skin of the flap C was denuded along the nasal columella crease and the muscle was sutured to the alar base for augmentation of nostril floor on the cleft side. The tip of the advancement flap was sutured at the midpoint of nasal columella crease and the skin of nasal floor was trimmed to hide the incision line around the nasal columella base. It was found that the Cupid's bow was rebuilt in a natural form and the configuration of the upper lip was reconstructed symmetrically. The long term follow up studies showed that the philtrum column was not disturbed by the small triangle flap and the nasal floor was rebuilt without obvious scars. The modified Onizuka cheiloplasty is an easy learning technique and efficient for repairing the unilateral cleft lip. This technique can satisfy the patients by reducing the length of scar as well as rebuilding a natural form of upper lip and nostril floor.

  3. Latest Quaternary rapid river incision across an inactive fold in the northern Chinese Tian Shan foreland

    Science.gov (United States)

    Lu, Honghua; Cheng, Lu; Wang, Zhen; Zhang, Tianqi; Lü, Yanwu; Zhao, Junxiang; Li, Youli; Zheng, Xiangmin

    2018-01-01

    This work focuses on the incision process over the Tuostai anticline, a fold of the proximal structure Belt I in the northern Chinese Tian Shan foreland, where the Sikeshu River has incised deeply into the alluvial gravels and the fold's underlying bedrock strata. Field investigation and geomorphic mapping define five terraces of the Sikeshu River (designated as T1 to T5 from oldest to youngest) preserved within the Tuostai anticline. 10Be surface exposure dating and optically stimulated luminescence dating constrain stabilization of the highest three terrace surfaces at about 80 ka (T1), 16 ka (T2), and 15 ka (T3), respectively. Around 16 ka, the calculated river incision rates significantly increase from 6 mm/yr. Undeformed longitudinal profiles of terraces T2, T3 and T4 over the Tuostai anticline suggest that this structure may have been tectonically inactive since stabilization of these three terraces. We thus think that the observed rapid river incision over the Tuostai anticline has not been largely forced by tectonic uplift. Instead, the progressively warmer and wetter palaeoclimatic condition within the Tian Shan range and its surrounding area during the period of ∼20-10 ka may have enhanced river incision across the Tuostai anticline. A reduced sediment/water ratio might have lowered the gradient of the Sikeshu River.

  4. Circumareolar incision-subdermal tunneling dissection for excision of multiple breast fibroadenomata

    Directory of Open Access Journals (Sweden)

    S O Agodirin

    2017-01-01

    Full Text Available Excision of multiple fibroadenomas (MF in separate breast quadrants presents difficulties of number and location of incision(s and extent of tissue dissection and may be associated with more complications and poorer cosmetic outcome. This is a report of excision of MF in multiple quadrants of the breast using a modification of subcutaneous dissection technique dubbed the circumareolar incision and subdermal tunneling (CAST dissection. After exposure of the superficial fascia with circumareolar incision, subdermal cone-wise dissection was made to allow mobilization of the segment bearing the lump(s. The lump(s were enucleated and removed. MF were removed from four breasts in three young unmarried females. The first patient had multiple adenomas removed from three quadrants of both breasts: 14 on the right and six on the left. The second patient had excision of three lumps in three separate quadrants, and the third patient had excision of two lumps in two separate quadrants. All patients had edema and bruising. One breast had wound infection and dehiscence. There were no skin necrosis, no nipple loss, and no breast distortion. All ensuing scars were camouflaged. CAST dissection was used for excision of MF in multiple quadrants of the breast with preservation of excellent cosmetic outcome of a single circumareolar incision.

  5. Panoramic radiographs underestimate extensions of the anterior loop and mandibular incisive canal

    Energy Technology Data Exchange (ETDEWEB)

    De Brito, Ana Caroline Ramos; Nejaim, Yuri; De Freitas, Deborah Queiroz [Dept. of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Sao Paulo (Brazil); De Oliveira Santos, Christiano [Dept. of Stomatology, Public Oral Health and Forensic Dentistry, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Sao Paulo (Brazil)

    2016-09-15

    The purpose of this study was to detect the anterior loop of the mental nerve and the mandibular incisive canal in panoramic radiographs (PAN) and cone-beam computed tomography (CBCT) images, as well as to determine the anterior/mesial extension of these structures in panoramic and cross-sectional reconstructions using PAN and CBCT images. Images (both PAN and CBCT) from 90 patients were evaluated by 2 independent observers. Detection of the anterior loop and the incisive canal were compared between PAN and CBCT. The anterior/mesial extension of these structures was compared between PAN and both cross-sectional and panoramic CBCT reconstructions. In CBCT, the anterior loop and the incisive canal were observed in 7.7% and 24.4% of the hemimandibles, respectively. In PAN, the anterior loop and the incisive canal were detected in 15% and 5.5% of cases, respectively. PAN presented more difficulties in the visualization of structures. The anterior/mesial extensions ranged from 0.0 mm to 19.0 mm on CBCT. PAN underestimated the measurements by approximately 2.0 mm. CBCT appears to be a more reliable imaging modality than PAN for preoperative workups of the anterior mandible. Individual variations in the anterior/mesial extensions of the anterior loop of the mental nerve and the mandibular incisive canal mean that is not prudent to rely on a general safe zone for implant placement or bone surgery in the interforaminal region.

  6. Two hundred seventy-five single-incision laparoscopic gastric band insertions: what have we learnt?

    Science.gov (United States)

    Murgatroyd, Beth; Chakravartty, Saurav; Sarma, Diwakar R; Patel, Ameet G

    2014-07-01

    Single-incision surgery in the morbidly obese patient has not been widely adopted, but remains a popular choice amongst patients. In the bariatric patient, it presents its own surgical challenges with hepatomegaly and increased abdominal adiposity. Here, we present our experience of 275 single-incision laparoscopic gastric bands.Between June 2009 and April 2013, 275 obese patients underwent single-incision laparoscopic adjustable gastric banding through a single incision using a multichannel single port and via a pars flaccida approach. Prospective data collection was undertaken including operating time, additional ports and additional procedures undertaken.In this series, median operative time was 60 (range 34-170) min. An additional port was placed in 15 patients (5%), including two conversions to four-port technique (0.7%). Of these patients (n = 15), the majority were male (p rate of success for all BMIs. Following 275 single-incision band insertions additional port placements were more commonly required in male patients, BMI >45 and earlier in the learning curve.

  7. Microincision versus small-incision coaxial cataract surgery using different power modes for hard nuclear cataract.

    Science.gov (United States)

    Kim, Eun Chul; Byun, Yong Soo; Kim, Man Soo

    2011-10-01

    To compare the efficacy of microincision and small-incision coaxial phacoemulsification in treating hard cataracts using different ultrasound power modes. Department of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea. Randomized clinical trial. Eyes with hard cataract were randomized to have an initial incision of 1.80 mm, 2.20 mm, or 2.75 mm. The eyes in each group were equally randomized to treatment with burst, pulse, or continuous mode. Ultrasound time (UST), mean cumulative dissipated energy (CDE), corrected distance visual acuity (CDVA), surgically induced corneal astigmatism, incisional and central corneal thickness (CCT), and endothelial cell counts were evaluated. The study enrolled 180 eyes, 60 in each group. Two months postoperatively, there were no statistically significant differences in UST, CDE, CDVA, CCT, or percentage endothelial cell loss between the 3 incision groups. The 2.75 mm incision induced more astigmatism at 2 months and less incisional corneal edema at 1 week than the 1.80 mm or 2.20 mm incision (Phard cataract. The intraoperative energy use and ocular damage was less with the pulse and burst modes than with the continuous mode. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Incision and stress regulation in borderline personality disorder: neurobiological mechanisms of self-injurious behaviour.

    Science.gov (United States)

    Reitz, Sarah; Kluetsch, Rosemarie; Niedtfeld, Inga; Knorz, Teresa; Lis, Stefanie; Paret, Christian; Kirsch, Peter; Meyer-Lindenberg, Andreas; Treede, Rolf-Detlef; Baumgärtner, Ulf; Bohus, Martin; Schmahl, Christian

    2015-08-01

    Patients with borderline personality disorder frequently show non-suicidal self-injury (NSSI). In these patients, NSSI often serves to reduce high levels of stress. Investigation of neurobiological mechanisms of NSSI in borderline personality disorder. In total, 21 women with borderline personality disorder and 17 healthy controls underwent a stress induction, followed by either an incision into the forearm or a sham treatment. Afterwards participants underwent resting-state functional magnetic resonance imaging while aversive tension, heart rate and heart rate variability were assessed. We found a significant influence of incision on subjective and objective stress levels with a stronger decrease of aversive tension in the borderline personality disorder group following incision than sham. Amygdala activity decreased more and functional connectivity with superior frontal gyrus normalised after incision in the borderline personality disorder group. Decreased stress levels and amygdala activity after incision support the assumption of an influence of NSSI on emotion regulation in individuals with borderline personality disorder and aids in understanding why these patients use self-inflicted pain to reduce inner tension. © The Royal College of Psychiatrists 2015.

  9. Force modeling for incisions into various tissues with MRF haptic master

    Science.gov (United States)

    Kim, Pyunghwa; Kim, Soomin; Park, Young-Dai; Choi, Seung-Bok

    2016-03-01

    This study proposes a new model to predict the reaction force that occurs in incisions during robot-assisted minimally invasive surgery. The reaction force is fed back to the manipulator by a magneto-rheological fluid (MRF) haptic master, which is featured by a bi-directional clutch actuator. The reaction force feedback provides similar sensations to laparotomy that cannot be provided by a conventional master for surgery. This advantage shortens the training period for robot-assisted minimally invasive surgery and can improve the accuracy of operations. The reaction force modeling of incisions can be utilized in a surgical simulator that provides a virtual reaction force. In this work, in order to model the reaction force during incisions, the energy aspect of the incision process is adopted and analyzed. Each mode of the incision process is classified by the tendency of the energy change, and modeled for realistic real-time application. The reaction force model uses actual reaction force information with three types of actual tissues: hard tissue, medium tissue, and soft tissue. This modeled force is realized by the MRF haptic master through an algorithm based on the position and velocity of a scalpel using two different control methods: an open-loop algorithm and a closed-loop algorithm. The reaction forces obtained from the proposed model are compared with a desired force in time domain.

  10. Uptake of gallium-67 citrate in clean surgical incisions after colorectal surgery

    International Nuclear Information System (INIS)

    Lin Wanyu; Wang Shyhjen; Tsai Shihchuan; Chao Tehsin

    2001-01-01

    Non-specific accumulation of gallium-67 citrate (gallium) in uncomplicated surgical incisions is not uncommon. It is important to know the normal pattern of gallium uptake at surgical incision sites in order to properly interpret the gallium scan when investigating possible wound infection in patients who have undergone abdominal surgery. We studied 42 patients without wound infection after colorectal surgery and performed gallium scans within 40 days after surgery. Patients were divided into three groups according to the interval between the operation and the scan. In group A (26 patients) gallium scan was performed within 7 days after surgery, in group B (8 patients) between 8 and 14 days after surgery, and in group C (8 patients) between 15 and 40 days after surgery. Our data showed that in group A, 61.5% had gallium accumulation at the surgical incision site. In group B, 50% had accumulation of gallium at the surgical incision site, while in group C only one patient (12.5%) showed gallium uptake. It is concluded that the incidence of increased gallium uptake at clean surgical incision sites is high after colorectal surgery. Nuclear medicine physicians should bear in mind the high incidence of non-specific gallium uptake at such sites during the interpretation of possible wound infection in patients after colorectal surgery. (orig.)

  11. Single incision laparoscopic pancreas resection for pancreatic metastasis of renal cell carcinoma.

    Science.gov (United States)

    Barbaros, Umut; Sümer, Aziz; Demirel, Tugrul; Karakullukçu, Nazlı; Batman, Burçin; Içscan, Yalın; Sarıçam, Gülay; Serin, Kürçsat; Loh, Wei-Liang; Dinççağ, Ahmet; Mercan, Selçuk

    2010-01-01

    Transumbilical single incision laparoscopic surgery (SILS) offers excellent cosmetic results and may be associated with decreased postoperative pain, reduced need for analgesia, and thus accelerated recovery. Herein, we report the first transumbilical single incision laparoscopic pancreatectomy case in a patient who had renal cell cancer metastasis on her pancreatic corpus and tail. A 59-year-old female who had metastatic lesions on her pancreas underwent laparoscopic subtotal pancreatectomy through a 2-cm umbilical incision. Single incision pancreatectomy was performed with a special port (SILS port) and articulated equipment. The procedure lasted 330 minutes. Estimated blood loss was 100mL. No perioperative complications occurred. The patient was discharged on the seventh postoperative day with a low-volume (20mL/day) pancreatic fistula that ceased spontaneously. Pathology result of the specimen was renal cell cancer metastases. This is the first reported SILS pancreatectomy case, demonstrating that even advanced surgical procedures can be performed using the SILS technique in well-experienced centers. Transumbilical single incision laparoscopic pancreatectomy is feasible and can be performed safely in experienced centers. SILS may improve cosmetic results and allow accelerated recovery for patients even with malignancy requiring advanced laparoscopic interventions.

  12. A Semicircular Incision in the Superior Umbilical Fold for SILS Preserves the Umbilical Profile

    Directory of Open Access Journals (Sweden)

    S. C. Blackburn

    2012-01-01

    Full Text Available Background. Single Incision Laparoscopic Surgery (SILS has been highlighted in the recent literature as a means of performing a range of common, minimal access, paediatric surgical procedures. The primary attraction is the absence of visible scarring. Aim. This study aims to describe a cosmetically advantageous means of SILS port placement in children, which preserves the umbilical profile. Methods. We describe a paediatric case series utilising a semicircular incision in the superior umbilical fold for SILS procedures. The linea alba is exposed over 2 cm just superior to the umbilical ring and stay sutures are applied. A vertical incision is made over this distance without entering the umbilical ring. Data were recorded prospectively in a Microsoft Excel database. Results. Twenty-one cases were performed in a 1-year period. Ten appendicectomies, 5 ovarian/paraovarian cystectomies, 2 Palomo procedures, 3 nephrectomy/heminephrectomies, and 1 Meckel’s diverticulectomy were performed. There was 1 wound infection. No incisional hernias occurred. Discussion. We believe that our technique, which maintains the integrity of the umbilical ring and allows preservation of the umbilical profile, offers a distinct cosmetic advantage over other incisions for SILS which distort it. Conclusion. We have demonstrated the aesthetic benefits of utilising a superior umbilical-fold incision for SILS in children.

  13. A Semicircular Incision in the Superior Umbilical Fold for SILS Preserves the Umbilical Profile.

    Science.gov (United States)

    Blackburn, S C; Adams, S D; Mahomed, A A

    2012-01-01

    Background. Single Incision Laparoscopic Surgery (SILS) has been highlighted in the recent literature as a means of performing a range of common, minimal access, paediatric surgical procedures. The primary attraction is the absence of visible scarring. Aim. This study aims to describe a cosmetically advantageous means of SILS port placement in children, which preserves the umbilical profile. Methods. We describe a paediatric case series utilising a semicircular incision in the superior umbilical fold for SILS procedures. The linea alba is exposed over 2 cm just superior to the umbilical ring and stay sutures are applied. A vertical incision is made over this distance without entering the umbilical ring. Data were recorded prospectively in a Microsoft Excel database. Results. Twenty-one cases were performed in a 1-year period. Ten appendicectomies, 5 ovarian/paraovarian cystectomies, 2 Palomo procedures, 3 nephrectomy/heminephrectomies, and 1 Meckel's diverticulectomy were performed. There was 1 wound infection. No incisional hernias occurred. Discussion. We believe that our technique, which maintains the integrity of the umbilical ring and allows preservation of the umbilical profile, offers a distinct cosmetic advantage over other incisions for SILS which distort it. Conclusion. We have demonstrated the aesthetic benefits of utilising a superior umbilical-fold incision for SILS in children.

  14. Postreplicative Mismatch Repair

    Science.gov (United States)

    Jiricny, Josef

    2013-01-01

    The mismatch repair (MMR) system detects non-Watson–Crick base pairs and strand misalignments arising during DNA replication and mediates their removal by catalyzing excision of the mispair-containing tract of nascent DNA and its error-free resynthesis. In this way, MMR improves the fidelity of replication by several orders of magnitude. It also addresses mispairs and strand misalignments arising during recombination and prevents synapses between nonidentical DNA sequences. Unsurprisingly, MMR malfunction brings about genomic instability that leads to cancer in mammals. But MMR proteins have recently been implicated also in other processes of DNA metabolism, such as DNA damage signaling, antibody diversification, and repair of interstrand cross-links and oxidative DNA damage, in which their functions remain to be elucidated. This article reviews the progress in our understanding of the mechanism of replication error repair made during the past decade. PMID:23545421

  15. Development of visible and NIR imaging equipment for small animals with smart pad.

    Science.gov (United States)

    Eum, Nyeon Sik; Han, Jung Hyun; Seong, Ki Woong; Lee, Jong Ha; Park, Hee Joon

    2014-01-01

    The portable visible and near-infrared (NIR) imaging equipment for a pre-clinical test with small animals was designed and developed in this paper. The developed equipment is composed of a CCD camera, a focusing lens, an objective lens, a NIR band pass filter and a NIR filter driving motor. An NIR ray is mainly used for imaging equipment because it has high light penetration depth in biological tissue. Therefore, NIR fluorescent agents are available for chemical conjugation to targeting molecules in vivo. This equipment can provide a visible image, NIR image and merged image simultaneously. A communication system was specifically established to check obtained images through a smart pad in real time. It is less dependent on space and time than the conventional system.

  16. DNA repair and cancer

    International Nuclear Information System (INIS)

    Rathore, Shakuntla; Joshi, Pankaj Kumar; Gaur, Sudha

    2012-01-01

    DNA repair refers to a collection of processes by which a cell identifies and corrects damage to the DNA molecule that encode it's genome. In human cells, both normal metabolic activities and environmental factors such as UV light and radiation can cause DNA damage, resulting in as many one million individual molecular lesions per day. Many of these lesions cause structural damage to the DNA molecule and can alter or eliminate the cell's ability to transcribe the gene that the affected DNA encodes. Other lesions include potentially harmful mutation in cell's genome which affect the survival of it's daughter cells after it undergoes mitosis. As a consequence, the DNA repair process is constantly active as it responds to damage in the DNA structure. Inherited mutation that affect DNA repair genes are strongly associated with high cancer risks in humans. Hereditary non polyposis colorectal cancer (HNPCC) is strongly associated with specific mutation in the DNA mismatch repair pathway. BRCA1, BRCA2 two famous mutation conferring a hugely increased risk of breast cancer on carrier, are both associated with a large number of DNA repair pathway, especially NHEJ and homologous recombination. Cancer therapy procedures such as chemotherapy and radiotherapy work by overwhelming the capacity of the cell to repair DNA damage, resulting in cell death. Cells that are most rapidly dividing most typically cancer cells are preferentially affected. The side effect is that other non-cancerous but rapidly dividing cells such as stem cells in the bone marrow are also affected. Modern cancer treatment attempt to localize the DNA damage to cells and tissue only associated with cancer, either by physical means (concentrating the therapeutic agent in the region of the tumor) or by biochemical means (exploiting a feature unique to cancer cells in the body). (author)

  17. Surgical repair of chronic rupture of the distal end of the biceps brachii. A modified anterior surgical repair technique.

    Science.gov (United States)

    Sharma, Dinesh K; Goswami, Ved; Wood, Jane

    2004-06-01

    The authors have used a modified surgical technique for repair of the distal end of the biceps brachii in three patients who presented with chronic rupture, all more than 6 weeks old. All patients were males; two lesions were on the dominant right side and one was on the non-dominant left side. An anterior incision was made over the cubital fossa, a hole was drilled over the radial tuberosity and a simple pull-through technique with an Ethibond suture was used to attach the tendon to an endobutton over the posterior surface of the radius. All patients returned to their employment and preinjury activity levels by six months. There were no postoperative complications and clinically all repairs remained intact. The patients regained their normal range of movements in 3 months; all but one regained the endurance and strength of their bicep in 6 months as assessed by Cybex testing. Surgical repair of the distal end of the biceps using the technique reported has given excellent results in these three patients.

  18. Nuclear fuel assembly repair

    International Nuclear Information System (INIS)

    Bassler, E.A.; Stavsky, R.

    1986-01-01

    In response to utility needs to recover investment in nuclear fuel assemblies, Westinghouse Electric Corporation has developed tools and equipment to repair damaged fuel assemblies in an economical and safe manner, to enable utilities to reinsert these assemblies in the core. There are two possible repair techniques - bottom nozzle reconstitution and top nozzle reconstitution. Both techniques have been approved through formal design review; prototype tools have been built and successfully tested. The tools are modular in nature, easily transportable, and designed to fit the spent fuel pool at a reactor site. (author)

  19. Biological radiolesions and repair

    International Nuclear Information System (INIS)

    Laskowski, W.

    1981-01-01

    In 7 chapters, the book answers the following questions: 1) What reactions are induced in biological matter by absorption of radiation energy. 2) In what parts of the cell do the radiation-induced reactions with detectable biological effects occur. 3) In which way are these cell components changed by different qualities of radiation. 4) What are the cell mechanisms by which radiation-induced changes can be repaired. 5) What is the importance of these repair processes for man, his life and evolution. At the end of each chapter, there is a bibliography of relevant publications in this field. (orig./MG) [de

  20. Comparison of the effects of 23-gauge and 25-gauge microincision vitrectomy blade designs on incision architecture.

    Science.gov (United States)

    Inoue, Makoto; Abulon, Dina Joy K; Hirakata, Akito

    2014-01-01

    To compare the effects of different 23- and 25-gauge microincision vitrectomy trocar cannula entry systems on incision architecture. We tested one ridged microvitreoretinal (MVR), one non-ridged MVR, one pointed beveled, and one round-tipped beveled blade (n=10 per blade design per incision type). Each blade's straight and oblique incision architecture was assessed in a silicone disc simulating the sclera. Wound leakage under pressure and endoscopic observations were conducted on sclerotomy sites of isolated porcine eyes (n=4 per blade design) after simulated vitrectomy. Differences in blade design created distinct incision architecture. Incisions were linear with the ridged MVR blade, flattened "M-shaped" with the non-ridged MVR blade, asymmetrical chevron-shaped with the pointed beveled blade, and curved with the round-tipped beveled blade. With the exception of oblique entry incision thickness, both MVR blade designs created thinner incisions than the beveled blades at entry and exit sites. Only the ridged MVR blade created incisions with no leakage. Vitreous incarceration was observed with all trocar cannula systems. Wound closure in porcine eyes was similar with all blades despite differences in incision architecture. Wound leakage occurred at low to moderate infusion pressures with most blades; no wound leakage was observed with ridged MVR blades.

  1. Oral subcutaneous midline leiomyomatous hamartoma presenting as congenital incisive papilla overgrowth in a toddler

    Directory of Open Access Journals (Sweden)

    Ashish Loomba

    2017-01-01

    Full Text Available Congenital soft-tissue tumors of oral cavity are mostly hyperplastic and benign in nature. This article presents an unusual case of congenital subcutaneous hamartoma of incisive papilla in a 2-year-old female child causing feeding and breathing difficulty. Total excisional biopsy was done under local anesthesia. Histopathology of tissue in reticulin-stained slide showed the presence of immature muscle fibers whereas Masson's trichrome stain revealed collagen fibers and smooth muscles confirming the diagnosis of oral midline subcutaneous smooth muscle (leiomyomatous hamartoma of incisive papilla. It is important for dental professionals to be aware of this oral lesion present from birth mimicking overgrowth of incisive papilla, by its presentation, differential diagnosis, histopathology, and management.

  2. Influence of Lateral Incision on Inhomogeneous Deformation of a Nickel [001] - Single Cristal at Axial Compression

    Science.gov (United States)

    Lychagin, D. V.; Alfyorova, E. A.; Lychagin, M. V.; Dilun, Czyan

    2016-04-01

    We used the scanning electron microscopy and the electron backscattered diffraction to investigate a deformation relief and a crystallographic disorientation of a nickel [001] single crystal with {100} faces with a lateral incision. We identified that the lateral incision can change the shear domains distribution pattern in the sample by creating additional deformation domains near the incision. The change in the patterns of the misorientation accumulation on the mutually perpendicular faces accompanies this deformation. We established that the orientation alteration occurs toward the increase of the Schmid factor for the slip systems in two of the four (previously equally loaded) slip planes. This method of shear deformation contributes to an optimal mutually consistent deformation in the adjacent areas of the single crystal.

  3. Incision of the heart during meat inspection of fattening pigs - A risk-profile approach.

    Science.gov (United States)

    Leps, J; Fries, R

    2009-01-01

    Meat inspection in the EU is based on Regulation (EC) 854/2004. Accordingly a risk based meat inspection should be implemented. In this paper, the incision of the heart in pig meat inspection is discussed with respect to efficacy. The incision especially can reveal the presence of endocarditis. Here, Erysipelothrixrhusiopathiae (E. rhusiopathiae) and/or Streptococcussuis (S. suis) are of particular concern. Both agents are regarded to be zoonotic agents. There is some evidence for infection of humans via an alimentary pathway. Hence, the occurrence of E. rhusiopathiae and S. suis is a concern of public health (PH) as well as veterinary public health (VPH). However, other measures, including on-farm disease prevention and diagnosis, seem to be more important for food safety. It is concluded that the incision and inspection of the heart is not justifiable with respect to PH aspects.

  4. Saccharomyces cerevisiae MutLα IS A MISMATCH REPAIR ENDONUCLEASE*

    Science.gov (United States)

    Kadyrov, Farid A.; Holmes, Shannon F.; Arana, Mercedes E.; Lukianova, Olga A.; O’Donnell, Mike; Kunkel, Thomas A.; Modrich, Paul

    2008-01-01

    MutL homologs are crucial for mismatch repair and genetic stability, but their function is not well understood. Human MutLα (MLH1-PMS2 heterodimer) harbors a latent endonuclease that is dependent on integrity of a PMS2 DQHA(X)2E(X)4E motif (Kadyrov et al. (2006) Cell 126, 297-308). This sequence element is conserved in many MutL homologs, including the PMS1 subunit of Saccharomyces cerevisiae MutLα, but is absent in MutL proteins from bacteria like Escherichia coli that rely on d(GATC) methylation for strand directionality. We show that yeast MutLα is a strand-directed endonuclease that incises DNA in a reaction that depends on a mismatch, yMutSα, yRFC, yPCNA, ATP, and a pre-existing strand break, whereas E. coli MutL is not. Amino acid substitution within the PMS1 DQHA(X)2E(X)4E motif abolishes yMutLα endonuclease activity in vitro and confers strong genetic instability in vivo, but does not affect yMutLα ATPase activity or the ability of the protein to support assembly of the yMutLα•yMutSα•heteroduplex ternary complex. The loaded form of yPCNA may play an important effector role in directing yMutLα incision to the discontinuous strand of a nicked heteroduplex. PMID:17951253

  5. Elevated metals compromise repair of oxidative DNA damage via the base excision repair pathway: implications of pathologic iron overload in the brain on integrity of neuronal DNA.

    Science.gov (United States)

    Li, Hui; Swiercz, Rafal; Englander, Ella W

    2009-09-01

    Tissue-specific iron content is tightly regulated to simultaneously satisfy specialized metabolic needs and avoid cytotoxicity. In the brain, disruption of iron homeostasis may occur in acute as well as progressive injuries associated with neuronal dysfunction and death. We hypothesized that adverse effects of disrupted metal homeostasis on brain function may involve impairment of DNA repair processes. Because in the brain, the base excision repair (BER) pathway is central for handling oxidatively damaged DNA, we investigated effects of elevated iron and zinc on key BER enzymes. In vitro DNA repair assays revealed inhibitory effects of metals on BER activities, including the incision of abasic sites, 5'-flap cleavage, gap filling DNA synthesis and ligation. Using the comet assay, we showed that while metals at concentrations which inhibit BER activities in in vitro assays, did not induce direct genomic damage in cultured primary neurons, they significantly delayed repair of genomic DNA damage induced by sublethal exposure to H(2)O(2). Thus, in the brain even a mild transient metal overload, may adversely affect the DNA repair capacity and thereby compromise genomic integrity and initiate long-term deleterious sequelae including neuronal dysfunction and death.

  6. Elevated metals compromise repair of oxidative DNA damage via the base excision repair pathway: implications of pathologic iron-overload in the brain on integrity of neuronal DNA

    Science.gov (United States)

    Li, Hui; Swiercz, Rafal; Englander, Ella W.

    2009-01-01

    Tissue-specific iron content is tightly regulated to simultaneously satisfy specialized metabolic needs and avoid cytotoxicity. In the brain, disruption of iron homeostasis may occur in acute as well as progressive injuries associated with neuronal dysfunction and death. We hypothesized that adverse effects of disrupted metal homeostasis on brain function may involve impairment of DNA repair processes. Since in the brain, the base excision repair (BER) pathway is central for handling oxidatively damaged DNA, we investigated effects of elevated iron and zinc on key BER enzymes. In vitro DNA repair assays revealed inhibitory effects of metals on BER activities, including the incision of abasic sites, 5’-flap cleavage, gap filling DNA synthesis and ligation. Using the comet assay, we showed that while metals at concentrations, which inhibit BER activities in in vitro assays, do not induce direct genomic damage in cultured primary neurons, they significantly delay repair of genomic DNA damage induced by sub-lethal exposure to H2O2. Thus, in the brain even a mild transient metal overload, may adversely affect the DNA repair capacity and thereby compromise genomic integrity and initiate long-term deleterious sequelae including neuronal dysfunction and death. PMID:19619136

  7. Groin hernia repair in young males: mesh or sutured repair?

    DEFF Research Database (Denmark)

    Bisgaard, T; Bay-Nielsen, M; Kehlet, H

    2010-01-01

    Large-scale data for the optimal inguinal hernia repair in younger men with an indirect hernia is not available. We analysed nationwide data for risk of reoperation in younger men after a primary repair using a Lichtenstein operation or a conventional non-mesh hernia repair....

  8. Electro active repair of concrete: innovation for increased repair durability

    NARCIS (Netherlands)

    Polder, R.B.; Geiker, M.R.

    2017-01-01

    Many repairs of chloride induced corrosion in practice fail within 10 years due to chloride remaining after cleaning the steel, causing corrosion re-activation. An improvement of conventional repair was invented, Electro Active Repair, that electrochemically removes chlorides. After concrete

  9. Correlations between in situ denitrification activity and nir-gene abundances in pristine and impacted prairie streams

    International Nuclear Information System (INIS)

    Graham, David W.; Trippett, Clare; Dodds, Walter K.; O'Brien, Jonathan M.; Banner, Eric B.K.; Head, Ian M.; Smith, Marilyn S.; Yang, Richard K.; Knapp, Charles W.

    2010-01-01

    Denitrification is a process that reduces nitrogen levels in headwaters and other streams. We compared nirS and nirK abundances with the absolute rate of denitrification, the longitudinal coefficient of denitrification (i.e., K den , which represents optimal denitrification rates at given environmental conditions), and water quality in seven prairie streams to determine if nir-gene abundances explain denitrification activity. Previous work showed that absolute rates of denitrification correlate with nitrate levels; however, no correlation has been found for denitrification efficiency, which we hypothesise might be related to gene abundances. Water-column nitrate and soluble-reactive phosphorus levels significantly correlated with absolute rates of denitrification, but nir-gene abundances did not. However, nirS and nirK abundances significantly correlated with K den , as well as phosphorus, although no correlation was found between K den and nitrate. These data confirm that absolute denitrification rates are controlled by nitrate load, but intrinsic denitrification efficiency is linked to nirS and nirK gene abundances. - Denitrification efficiency best correlated to nirS and nirK gene abundances.

  10. Transcriptional repressor NIR interacts with the p53-inhibiting ubiquitin ligase MDM2.

    Science.gov (United States)

    Heyne, Kristina; Förster, Juliane; Schüle, Roland; Roemer, Klaus

    2014-04-01

    NIR (novel INHAT repressor) can bind to p53 at promoters and inhibit p53-mediated gene transactivation by blocking histone acetylation carried out by p300/CBP. Like NIR, the E3 ubiquitin ligase MDM2 can also bind and inhibit p53 at promoters. Here, we present data indicating that NIR, which shuttles between the nucleolus and nucleoplasm, not only binds to p53 but also directly to MDM2, in part via the central acidic and zinc finger domain of MDM2 that is also contacted by several other nucleolus-based MDM2/p53-regulating proteins. Like some of these, NIR was able to inhibit the ubiquitination of MDM2 and stabilize MDM2; however, unlike these nucleolus-based MDM2 regulators, NIR did not inhibit MDM2 to activate p53. Rather, NIR cooperated with MDM2 to repress p53-induced transactivation. This cooperative repression may at least in part involve p300/CBP. We show that NIR can block the acetylation of p53 and MDM2. Non-acetylated p53 has been documented previously to more readily associate with inhibitory MDM2. NIR may thus help to sustain the inhibitory p53:MDM2 complex, and we present evidence suggesting that all three proteins can indeed form a ternary complex. In sum, our findings suggest that NIR can support MDM2 to suppress p53 as a transcriptional activator.

  11. Mental Task Evaluation for Hybrid NIRS-EEG Brain-Computer Interfaces

    Directory of Open Access Journals (Sweden)

    Hubert Banville

    2017-01-01

    Full Text Available Based on recent electroencephalography (EEG and near-infrared spectroscopy (NIRS studies that showed that tasks such as motor imagery and mental arithmetic induce specific neural response patterns, we propose a hybrid brain-computer interface (hBCI paradigm in which EEG and NIRS data are fused to improve binary classification performance. We recorded simultaneous NIRS-EEG data from nine participants performing seven mental tasks (word generation, mental rotation, subtraction, singing and navigation, and motor and face imagery. Classifiers were trained for each possible pair of tasks using (1 EEG features alone, (2 NIRS features alone, and (3 EEG and NIRS features combined, to identify the best task pairs and assess the usefulness of a multimodal approach. The NIRS-EEG approach led to an average increase in peak kappa of 0.03 when using features extracted from one-second windows (equivalent to an increase of 1.5% in classification accuracy for balanced classes. The increase was much stronger (0.20, corresponding to an 10% accuracy increase when focusing on time windows of high NIRS performance. The EEG and NIRS analyses further unveiled relevant brain regions and important feature types. This work provides a basis for future NIRS-EEG hBCI studies aiming to improve classification performance toward more efficient and flexible BCIs.

  12. The effect of kidney morcellation on operative time, incision complications, and postoperative analgesia after laparoscopic nephrectomy

    Directory of Open Access Journals (Sweden)

    Affonso H. Camargo

    2006-06-01

    Full Text Available INTRODUCTION: Compare the outcomes between kidney morcellation and two types of open specimen extraction incisions, several covariates need to be taken into consideration that have not yet been studied. MATERIALS AND METHODS: We retrospectively reviewed 153 consecutive patients who underwent laparoscopic nephrectomy at our institution, 107 who underwent specimen morcellation and 46 with intact specimen removal, either those with connected port sites with a muscle-cutting incision and those with a remote, muscle-splitting incision. Operative time, postoperative analgesia requirements, and incisional complications were evaluated using univariate and multivariate analysis, comparing variables such as patient age, gender, body mass index (BMI, laterality, benign versus cancerous renal conditions, estimated blood loss, specimen weight, overall complications, and length of stay. RESULTS: There was no significant difference for operative time between the 2 treatment groups (p = 0.65. Incision related complications occurred in 2 patients (4.4% from the intact specimen group but none in the morcellation group (p = 0.03. Overall narcotic requirement was lower in patients with morcellated (41 mg compared to intact specimen retrieval (66 mg on univariate (p = 0.03 and multivariate analysis (p = 0.049. Upon further stratification, however, there was no significant difference in mean narcotic requirement between the morcellation and muscle-splitting incision subgroup (p = 0.14. CONCLUSION: Morcellation does not extend operative time, and is associated with significantly less postoperative pain compared to intact specimen retrieval overall, although this is not statistically significant if a remote, muscle-splitting incision is made. Morcellation markedly reduces the risk of incisional-related complications.

  13. Cutting electrocautery versus scalpel for surgical incisions: a systematic review and meta-analysis.

    Science.gov (United States)

    Ismail, Ammar; Abushouk, Abdelrahman Ibrahim; Elmaraezy, Ahmed; Menshawy, Amr; Menshawy, Esraa; Ismail, Mahmoud; Samir, Esraa; Khaled, Anas; Zakarya, Hagar; El-Tonoby, Abdelrahman; Ghanem, Esraa

    2017-12-01

    Although cutting electrocautery can be superior to the scalpel in reducing blood loss and incisional time, several reports associated electrocautery with higher rates of wound infection, impaired healing, and worse cosmesis. We performed this systematic review and meta-analysis to compare cutting electrocautery versus scalpel for surgical incisions. We conducted a computerized literature search of five electronic databases and included all published original studies comparing cutting electrocautery and scalpel surgical incisions. Relevant data were extracted from eligible studies and pooled as odds ratios (ORs) or standardized mean difference (SMD) values in a meta-analysis model, using RevMan and Comprehensive Meta-analysis software. Forty-one studies (36 randomized trials, four observational, and one quasirandom study) were included in the pooled analysis (6422 participants). Compared with the scalpel incision, cutting electrocautery resulted in significantly less blood loss (SMD = -1.16, 95% CI [-1.60 to -0.72]), shorter incisional (SMD = -0.63, 95% CI [-0.96 to -0.29]) and operative times (SMD = -0.59, 95% CI [-1.12 to -0.05]), and lower pain scores (SMD = -0.91, 95% CI [-1.27 to -0.55]) with no significant differences in terms of wound infection rates (OR = 0.92, 95% CI [0.74-1.15]) or overall subjective scar score (SMD = -0.49, 95% CI [-1.72 to 0.75]). Surgical incision using electrocautery can be quicker with less blood loss and postoperative pain scores than the scalpel incision. No statistically significant difference was found between both techniques in terms of postoperative wound complications, hospital stay duration, and wound cosmetic characteristics. Therefore, we recommend routine use of cutting electrocautery for surgical incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Ship Repair Workflow Cost Model

    National Research Council Canada - National Science Library

    McDevitt, Mike

    2003-01-01

    The effects of intermittent work patterns and funding on the costs of ship repair and maintenance were modeled for the San Diego region in 2002 for Supervisor of Shipbuilding and Repair (SUPSHIP) San Diego...

  15. Composite Repair System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — GTL has developed an innovative composite repair methodology known as the Composite Repair System (CRS). In this phase I effort, CRS is being developed for the...

  16. About the Collision Repair Campaign

    Science.gov (United States)

    EPA developed the Collision Repair Campaign to focus on meaningful risk reduction in the Collision Repair source sector to complement ongoing community air toxics work and attain reductions at a faster rate.

  17. Transitions in nirS-type denitrifier diversity, community composition, and biogeochemical activity along the Chesapeake Bay estuary.

    Science.gov (United States)

    Francis, Christopher A; O'Mullan, Gregory D; Cornwell, Jeffrey C; Ward, Bess B

    2013-01-01

    Chesapeake Bay, the largest estuary in North America, can be characterized as having steep and opposing gradients in salinity and dissolved inorganic nitrogen along the main axis of the Bay. In this study, the diversity of nirS gene fragments (encoding cytochrome cd 1-type nitrite reductase), physical/chemical parameters, and benthic N2-fluxes were analyzed in order to determine how denitrifier communities and biogeochemical activity vary along the estuary salinity gradient. The nirS gene fragments were PCR-amplified, cloned, and sequenced from sediment cores collected at five stations. Sequence analysis of 96-123 nirS clones from each station revealed extensive overall diversity in this estuary, as well as distinct spatial structure in the nirS sequence distributions. Both nirS-based richness and community composition varied among stations, with the most dramatic shifts occurring between low-salinity (oligohaline) and moderate-salinity (mesohaline) sites. For four samples collected in April, the nirS-based richness, nitrate concentrations, and N2-fluxes all decreased in parallel along the salinity gradient from the oligohaline northernmost station to the highest salinity (polyhaline) station near the mouth of the Bay. The vast majority of the 550 nirS sequences were distinct from cultivated denitrifiers, although many were closely related to environmental clones from other coastal and estuarine systems. Interestingly, 8 of the 172 OTUs identified accounted for 42% of the total nirS clones, implying the presence of a few dominant and many rare genotypes, which were distributed in a non-random manner along the salinity gradient of Chesapeake Bay. These data, comprising the largest dataset to investigate nirS clone sequence diversity from an estuarine environment, also provided information that was required for the development of nirS microarrays to investigate the interaction of microbial diversity, environmental gradients, and biogeochemical activity.

  18. Transitions in nirS-type Denitrifier Diversity, Community Composition, and Biogeochemical Activity along the Chesapeake Bay Estuary

    Directory of Open Access Journals (Sweden)

    Christopher A Francis

    2013-08-01

    Full Text Available Chesapeake Bay, the largest estuary in North America, can be characterized as having steep and opposing gradients in salinity and dissolved inorganic nitrogen along the main axis of the Bay. In this study, the diversity of nirS gene fragments (encoding cytochrome cd1-type nitrite reductase, physical/chemical parameters, and benthic N2-fluxes were analyzed in order to determine how denitrifier communities and biogeochemical activity vary along the estuary salinity gradient. The nirS gene fragments were PCR-amplified, cloned, and sequenced from sediment cores collected at five stations. Sequence analysis of 96 to 123 nirS clones from each station revealed extensive overall diversity in this estuary, as well as distinct spatial structure in the nirS sequence distributions. Both nirS-based richness and community composition varied among stations, with the most dramatic shifts occurring between low-salinity (oligohaline and moderate-salinity (mesohaline sites. For four samples collected in April, the nirS-based richness, nitrate concentrations, and N2-fluxes all decreased in parallel along the salinity gradient from the oligohaline northernmost station to the highest salinity (polyhaline station near the mouth of the Bay. The vast majority of the 550 nirS sequences were distinct from cultivated denitrifiers, although many were closely related to environmental clones from other coastal and estuarine systems. Interestingly, 8 of the 172 OTUs identified accounted for 42% of the total nirS clones, implying the presence of a few dominant and many rare genotypes, which were distributed in a non-random manner along the salinity gradient of Chesapeake Bay. These data, comprising the largest dataset to investigate nirS clone sequence diversity from an estuarine environment, also provided information that was required for the development of nirS microarrays to investigate the interaction of microbial diversity, environmental gradients, and biogeochemical

  19. Incision of the Yangtze River at the First Bend Determined by Three-Nuclide Burial Dating

    Science.gov (United States)

    McPhillips, D. F.; Hoke, G. D.; Rood, D. H.; Bierman, P. R.

    2015-12-01

    On the southeast margin of the Tibetan Plateau, the evolution of the Yangtze River and its major tributaries has become an important source of data for investigating geodynamics. In particular, the timing of river incision is frequently interpreted as a proxy for the timing of surface uplift in the absence of structural evidence. We investigate the timing of the incision of the gorge at the First Bend using cosmogenic nuclide burial dating of coarse, quartz sediments from caves. Sediments were deposited when the caves were near river level and subsequently abandoned as the river incised. To resolve burial ages >5 Ma, we measured the radionuclides 10Be and 26Al, and the stable nuclide 21Ne. Results from 4 caves show that 26Al and 10Be concentrations are an order of magnitude lower in abandoned cave samples than in a river-level cave sample where deposition is active (10Be: 1.3x104 and 3.4x105 at/g). In contrast, 26Al/10Be ratios in all caves are ≥6.2 and indistinguishable within error. 21Ne concentrations range from 2.1x106 to 7.8x106 at/g. The results are consistent with an old age for the abandoned cave deposits, such that most of the radionuclides initially present have decayed and the concentrations that we measure today are the result of millions of years of exposure to muons. We solve for burial ages, taking into account in situ muogenic production, and find that the majority of the gorge (1 km) was likely incised between ~12 and 9 Ma. The results also require that the rate of river incision declined after the gorge was cut below the lowest elevation cave at 9 Ma. Inverse modeling of published low-temperature thermochronology (Ouimet et al., 2010) supports our burial age results. River capture near the First Bend, which likely integrated the modern Yangtze, likely occurred prior to the mid-Miocene incision of the gorge. In view of the geographic position of the First Bend—just downslope from the southeast margin of the Plateau—it is difficult to explain

  20. Fingertip replantation using a single volar arteriovenous anastomosis and drainage with a transverse tip incision.

    Science.gov (United States)

    Yabe, T; Muraoka, M; Motomura, H; Ozawa, T

    2001-11-01

    Four cases of fingertip replantation using a single volar arteriovenous anastomosis and drainage with a transverse tip incision are reported. Because of lack of suitable arteries for anastomosis in the amputated finger, in each case a volar radial vein was anastomosed to the proximal digital artery and external drainage was performed through a transverse tip incision. In 3 cases the replanted fingertip survived completely; partial necrosis occurred in 1 case. Because veins are more superficial and larger than arteries, they are more available for anastomosis. The results indicate that this method is a useful alternative in fingertip replantation.

  1. Incision of the Jezero Crater Outflow Channel by Fluvial Sediment Transport

    Science.gov (United States)

    Holo, S.; Kite, E. S.

    2017-12-01

    Jezero crater, the top candidate landing site for the Mars 2020 rover, once possessed a lake that over-spilled and eroded a large outflow channel into the Eastern rim. The Western deltaic sediments that would be the primary science target of the rover record a history of lake level, which is modulated by the inflow and outflow channels. While formative discharges for the Western delta exist ( 500 m3/s), little work has been done to see if these flows are the same responsible for outflow channel incision. Other models of the Jezero outflow channel incision assume that a single rapid flood (incision timescales of weeks), with unknown initial hydraulic head and no discharge into the lake (e.g. from the inflow channels or the subsurface), incised an open channel with discharge modulated by flow over a weir. We present an alternate model where, due to an instability at the threshold of sediment motion, the incision of the outflow channel occurs in concert with lake filling. In particular, we assume a simplified lake-channel-valley system geometry and that the channel is hydraulically connected to the filling/draining crater lake. Bed load sediment transport and water discharge through the channel are quantified using the Meyer-Peter and Mueller relation and Manning's law respectively. Mass is conserved for both water and sediment as the lake level rises/falls and the channel incises. This model does not resolve backwater effects or concavity in the alluvial system, but it does capture the non-linear feedbacks between lake draining, erosion rate, channel flow rate, and slope relaxation. We identify controls on incision of the outflow channel and estimate the time scale of outflow channel formation through a simple dynamical model. We find that the observed 300m of channel erosion can be reproduced in decades to centuries of progressive bed load as the delta forming flows fill the lake. This corresponds to time scales on the order of or smaller than the time scale

  2. NIR spectrometry for counterfeit drug detection - A feasibility study

    DEFF Research Database (Denmark)

    Rodionova, O.Y.; Houmøller, Lars P.; Pomerantsev, A.L.

    2005-01-01

    for mathematical data processing for false drugs detection is demonstrated. Also, multivariate hyperspectral image analysis is applied providing additional diagnostic information. Hyperspectral imaging is becoming a useful diagnostic tool for identifying non-homogeneous spatial regions of drug formulation. Two......Express-methods for detection of counterfeit drugs are of vital necessity. Visual control, dissociating tests or simple color reaction tests reveal only very rough forgeries. The feasibility of information-rich NIR-measurements as an analytical method together with multivariate calibration...... types of drugs are used to demonstrate the applicability of these approaches....

  3. NIRS - Near infrared spectroscopy - investigations in neurovascular diseases

    DEFF Research Database (Denmark)

    Schytz, Henrik Winther

    2015-01-01

    The purpose of this thesis was to explore and develop methods, where continuous wave near infrared spectroscopy (CW-NIRS) can be applied in different neurovascular diseases, in order to find biological markers that are useful in clinical neurology. To develop a new method to detect changes...... to sympathetic activity was investigated in obstructive sleep apnoea (OSA) patients, who have increased sympathetic activity and risk of stroke. Following successful continuous positive airway pressure (CPAP) therapy, OSA patients decreased their LFOs amplitude, which was interpreted as a marker of decreased...

  4. In situ Vis NIR and Raman spectroelectrochemistry at fullerene peapods

    Science.gov (United States)

    Kavan, Ladislav; Dunsch, Lothar; Kataura, Hiromichi

    2002-07-01

    The population of valence-band electronic states of fullerene peapods (C 60@SWCNT) was tuned electrochemically in acetonitrile solutions. Electrochemistry of peapods was dominated by their capacitive charging without distinct faradaic processes. In situ Vis-NIR spectra of peapods showed similar features as those of empty nanotubes. Electrochemical charging caused reversible bleaching of the transitions between Van Hove singularities. This bleaching was mirrored by quenching of resonance Raman spectra of the tube-related modes. The A g(2) mode of C 60 exhibits considerable intensity increase upon anodic doping of peapods, but this mode is not enhanced at cathodic charging.

  5. [Visible-NIR spectral feature of citrus greening disease].

    Science.gov (United States)

    Li, Xiu-hua; Li, Min-zan; Won Suk, Lee; Reza, Ehsani; Ashish, Ratn Mishra

    2014-06-01

    Citrus greening (Huanglongbing, or HLB) is a devastating disease caused by Candidatus liberibacter which uses psyllids as vectors. It has no cure till now, and poses a huge threat to citrus industry around the world. In order to diagnose, assess and further control this disease, it is of great importance to first find a quick and effective way to detect it. Spectroscopy method, which was widely considered as a fast and nondestructive way, was adopted here to conduct a preliminary exploration of disease characteristics. In order to explore the spectral differences between the healthy and HLB infected leaves and canopies, this study measured the visible-NIR spectral reflectance of their leaves and canopies under lab and field conditions, respectively. The original spectral data were firstly preprocessed with smoothing (or moving average) and cluster average procedures, and then the first derivatives were also calculated to determine the red edge position (REP). In order to solve the multi-peak phenomenon problem, two interpolation methods (three-point Lagrangian interpolation and four-point linear extrapolation) were adopted to calculate the REP for each sample. The results showed that there were, obvious differences at the visible & NIR spectral reflectance between the healthy and HLB infected classes. Comparing with the healthy reflectance, the HLB reflectance was higher at the visible bands because of the yellowish symptoms on the infected leaves, and lower at NIR bands because the disease blocked water transportation to leaves. But the feature at NIR bands was easily affected by environmental factors such as light, background, etc. The REP was also a potential indicator to distinguish those two classes. The average REP was slowly moving toward red bands while the infection level was getting higher. The gap of the average REPs between the healthy and HLB classes reached to a maximum of 20 nm. Even in the dataset with relatively lower variation, the classification

  6. Enhanced surface structuring by ultrafast XUV/NIR dual action

    Czech Academy of Sciences Publication Activity Database

    Jakubczak, Krzysztof; Mocek, Tomáš; Chalupský, Jaromír; Lee, G.H.; Kim, T.K.; Park, S.B.; Nam, Ch. H.; Hájková, Věra; Toufarová, Martina; Juha, Libor; Rus, Bedřich

    2011-01-01

    Roč. 13, č. 5 (2011), s. 1-12 ISSN 1367-2630 R&D Projects: GA AV ČR KAN300100702; GA MŠk(CZ) LC528; GA MŠk LA08024; GA ČR GC202/07/J008 Grant - others:AV ČR(CZ) M100100911 Institutional research plan: CEZ:AV0Z10100523 Keywords : XUV beam * ultrafast NIR laser pulses * high-order harmonics * laser-induced periodic surface structures Subject RIV: BH - Optics, Masers, Lasers Impact factor: 4.177, year: 2011 http://iopscience.iop.org/1367-2630/13/5/053049

  7. New NIR Calibration Models Speed Biomass Composition and Reactivity Characterization

    Energy Technology Data Exchange (ETDEWEB)

    2015-09-01

    Obtaining accurate chemical composition and reactivity (measures of carbohydrate release and yield) information for biomass feedstocks in a timely manner is necessary for the commercialization of biofuels. This highlight describes NREL's work to use near-infrared (NIR) spectroscopy and partial least squares multivariate analysis to develop calibration models to predict the feedstock composition and the release and yield of soluble carbohydrates generated by a bench-scale dilute acid pretreatment and enzymatic hydrolysis assay. This highlight is being developed for the September 2015 Alliance S&T Board meeting.

  8. DNA Repair Systems

    Indian Academy of Sciences (India)

    Thanks to the pioneering research work of Lindahl, Sancar, Modrich and their colleagues, we now have an holistic awareness of how DNA damage occurs and how the damage is rectified in bacteria as well as in higher organisms including human beings. A comprehensive understanding of DNA repair has proven crucial ...

  9. DNA Repair Systems

    Indian Academy of Sciences (India)

    D N Rao is a professor at the. Department of Biochemistry,. Indian Institute of Science,. Bengaluru. His research work primarily focuses on. DNA interacting proteins in prokaryotes. This includes restriction-modification systems, DNA repair proteins from pathogenic bacteria and and proteins involved in horizontal gene ...

  10. Comprehensive Small Engine Repair.

    Science.gov (United States)

    Hires, Bill; And Others

    This curriculum guide contains the basic information needed to repair all two- and four-stroke cycle engines. The curriculum covers four areas, each consisting of one or more units of instruction that include performance objectives, suggested activities for teacher and students, information sheets, assignment sheets, job sheets, visual aids,…

  11. Aircraft Propeller Hub Repair

    Energy Technology Data Exchange (ETDEWEB)

    Muth, Thomas R [ORNL; Peter, William H [ORNL

    2015-02-13

    The team performed a literature review, conducted residual stress measurements, performed failure analysis, and demonstrated a solid state additive manufacturing repair technique on samples removed from a scrapped propeller hub. The team evaluated multiple options for hub repair that included existing metal buildup technologies that the Federal Aviation Administration (FAA) has already embraced, such as cold spray, high velocity oxy-fuel deposition (HVOF), and plasma spray. In addition the team helped Piedmont Propulsion Systems, LLC (PPS) evaluate three potential solutions that could be deployed at different stages in the life cycle of aluminum alloy hubs, in addition to the conventional spray coating method for repair. For new hubs, a machining practice to prevent fretting with the steel drive shaft was recommended. For hubs that were refurbished with some material remaining above the minimal material condition (MMC), a silver interface applied by an electromagnetic pulse additive manufacturing method was recommended. For hubs that were at or below the MMC, a solid state additive manufacturing technique using ultrasonic welding (UW) of thin layers of 7075 aluminum to the hub interface was recommended. A cladding demonstration using the UW technique achieved mechanical bonding of the layers showing promise as a viable repair method.

  12. Role of DNA repair in repair of cytogenetic damages. Slowly repaired DNA injuries involved in cytogenetic damages repair

    International Nuclear Information System (INIS)

    Zaichkina, S.I.; Rozanova, O.M.; Aptikaev, G.F.; Ganassi, E.Eh.

    1989-01-01

    Caffeine was used to study the kinetics of cytogenetic damages repair in Chinese hamster fibroblasts. Its half-time (90 min) was shown to correlate with that of repair of slowly repaired DNA damages. The caffeine-induced increase in the number of irreparable DNA damages, attributed to inhibition of double-strand break repair, is in a quantitative correlation with the effect of the cytogenetic damage modification

  13. The journey of DNA repair.

    Science.gov (United States)

    Saini, Natalie

    2015-12-01

    21 years ago, the DNA Repair Enzyme was declared "Molecule of the Year". Today, we are celebrating another "year of repair", with the 2015 Nobel Prize in Chemistry being awarded to Aziz Sancar, Tomas Lindahl and Paul Modrich for their collective work on the different DNA repair pathways.

  14. DNA repair in human cells

    International Nuclear Information System (INIS)

    Regan, J.D.; Carrier, W.L.; Kusano, I.; Furuno-Fukushi, I.; Dunn, W.C. Jr.; Francis, A.A.; Lee, W.H.

    1982-01-01

    Our primary objective is to elucidate the molecular events in human cells when cellular macromolecules such as DNA are damaged by radiation or chemical agents. We study and characterize (i) the sequence of DNA repair events, (ii) the various modalities of repair, (iii) the genetic inhibition of repair due to mutation, (iv) the physiological inhibition of repair due to mutation, (v) the physiological inhibition of repair due to biochemical inhibitors, and (vi) the genetic basis of repair. Our ultimate goals are to (i) isolate and analyze the repair component of the mutagenic and/or carcinogenic event in human cells, and (ii) elucidate the magnitude and significance of this repair component as it impinges on the practical problems of human irradiation or exposure to actual or potential chemical mutagens and carcinogens. The significance of these studies lies in (i) the ubiquitousness of repair (most organisms, including man, have several complex repair systems), (ii) the belief that mutagenic and carcinogenic events may arise only from residual (nonrepaired) lesions or that error-prone repair systems may be the major induction mechanisms of the mutagenic or carcinogenic event, and (iii) the clear association of repair defects and highly carcinogenic disease states in man [xeroderma pigmentosum (XP)

  15. Cleft lip and palate repair

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002979.htm Cleft lip and palate repair To use the sharing features on this ... Cheiloplasty; Cleft rhinoplasty; Palatoplasty; Tip rhinoplasty Patient Instructions Cleft lip and palate repair - discharge Images Cleft lip repair - series References ...

  16. Large Extremity Peripheral Nerve Repair

    Science.gov (United States)

    2016-12-01

    rodents as a function of time after surgery. As predicted, those animals in the negative control group (no repair following nerve deficit injury ...80% of penetrating injuries being associated with peripheral nerve damage, typically involve large segmental nerve deficits. Standard repair uses...technology for repair of peripheral nerve injuries involving significant neural deficit with improved functional outcomes for the wounded warrior. The

  17. Comparison of the effects of 23-gauge and 25-gauge microincision vitrectomy blade designs on incision architecture

    Directory of Open Access Journals (Sweden)

    Inoue M

    2014-11-01

    Full Text Available Makoto Inoue,1 Dina Joy K Abulon,2 Akito Hirakata1 1Kyorin Eye Center, School of Medicine, Kyorin University, Tokyo, Japan; 2Alcon Research, Ltd., Irvine, CA, USA Purpose: To compare the effects of different 23- and 25-gauge microincision vitrectomy trocar cannula entry systems on incision architecture.Methods: We tested one ridged microvitreoretinal (MVR, one non-ridged MVR, one pointed beveled, and one round-tipped beveled blade (n=10 per blade design per incision type. Each blade’s straight and oblique incision architecture was assessed in a silicone disc simulating the sclera. Wound leakage under pressure and endoscopic observations were conducted on sclerotomy sites of isolated porcine eyes (n=4 per blade design after simulated vitrectomy.Results: Differences in blade design created distinct incision architecture. Incisions were linear with the ridged MVR blade, flattened “M-shaped” with the non-ridged MVR blade, asymmetrical chevron-shaped with the pointed beveled blade, and curved with the round-tipped beveled blade. With the exception of oblique entry incision thickness, both MVR blade designs created thinner incisions than the beveled blades at entry and exit sites. Only the ridged MVR blade created incisions with no leakage. Vitreous incarceration was observed with all trocar cannula systems.Conclusion: Wound closure in porcine eyes was similar with all blades despite differences in incision architecture. Wound leakage occurred at low to moderate infusion pressures with most blades; no wound leakage was observed with ridged MVR blades. Keywords: entry system, incision closure, leakage, pars plana incision, sclerotomy, trocar blade 

  18. Simultaneous bilateral distal biceps tendon ruptures repaired using an endobutton technique: a case report.

    Science.gov (United States)

    Dacambra, Mark P; Walker, Richard Ea; Hildebrand, Kevin A

    2013-08-23

    The simultaneous rupture of both distal biceps tendons is a rare clinical entity that is difficult to treat and can have poor outcomes. A variety of treatment and rehabilitation options exist and have been reported for single sided and staged bilateral repairs, but none have described an approach for acute bilateral ruptures. Repairing distal biceps tendon ruptures using a single anterior incision and a cortical suspensory button technique has become increasingly popular in recent years. We present a report of our surgical approach using an endobutton technique and rehabilitation algorithm for this unusual injury pattern. A 43-year-old Caucasian man presented with acute onset bilateral elbow pain while lifting a large sheet of drywall off the ground. He initially felt a 'pop' on the right and almost immediately felt another on the left after having to quickly shift the weight. He was unable to continue working and sought medical attention. His pain was predominantly in his bilateral antecubital fossae and he had significant swelling and ecchymoses. His clinical examination demonstrated no palpable tendon, a retracted biceps muscle belly, and clear supination weakness. Magnetic resonance imaging was performed and showed bilateral distal biceps tendon ruptures with retraction on both sides. After discussion with our patient, we decided that both sides would be repaired using a single anterior incision with endobutton fixation, first his right followed by his left six weeks later. Overall, our patient did very well and had returned to full manual work by our last follow-up at 30 months. Although he was never able to return to competitive recreational hockey and was left with mild lateral antebrachial cutaneous nerve dysesthesias on his right, he felt he was at 85% of his premorbid level of function. We describe what we believe to be, to the best of our knowledge, the first case of simultaneous bilateral distal biceps tendon ruptures successfully treated with a single-incision

  19. Analysis of powder phenomena inside a Fette 3090 feed frame using in-line NIR spectroscopy.

    Science.gov (United States)

    Mateo-Ortiz, Daniel; Colon, Yleana; Romañach, Rodolfo J; Méndez, Rafael

    2014-11-01

    New analytical methods are needed to understand and optimize the processes by which tablets are produced. Fette 3090 tablet presses are commonly used in the pharmaceutical industry. A near-infrared (NIR) probe was installed into a Fette 3090 feed frame to understand and monitor the die filling process. The second objective was to analyze in detail the different factors that could affect the prediction of the developed NIR calibration models. Two monitoring positions for NIR spectrometers were evaluated; one at each side of the feed frame. A powder wave behavior caused by the paddle motion was observed inside the feed frame. The study also revealed that NIR spectra can help in the understanding of powder flow inside the feed frame. It was demonstrated that NIR spectra baselines can also be used to determine changes in mass inside the feed frame. The new NIR method showed that the paddle wheel speed has a significant impact in the powder dynamics inside the feed frame. The baselines of the NIR spectra depended on the mass hold-up inside the feed frame and paddle wheel speed. Studies using blends were performed to develop a NIR calibration model based on the feed frame system dynamics to determine acetaminophen drug concentration variability during the die filling process. The study found that variation in the distance from the powder to the probe due to paddle wheel speed has a significant effect on the NIR prediction. This study found that with NIR spectroscopy, blend uniformity can be assessed with high accuracy during the die filling process using the corresponding paddle wheel speed in-line calibration model. NIR was demonstrated to be a good development tool for the in-line monitoring of powder during the die filling process. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Quality control of tablets by Near Infrared (NIR)-Spectroscopy.

    Science.gov (United States)

    Petri, J; Kaunzinger, A; Niemöller, A; Karas, M

    2005-10-01

    Today, NIR-spectroscopy is an established analytical technique not only in the identification of raw materials but also in the quantification of active ingredients in tablets. In this work calibration models were set up with tablets of the same active ingredient but of miscellaneous origin and manufacturess. Consequently the tablets had different excipients and appearance. The pharmaceutical preparations used included atenolol 100 mg tablets, enalapril 20 mg tablets and acetylsalicylic acid (ASS) tablets of different dosage units. In order to proof if the calibration models set up are generally feasible the assay declared by the manufacturer was used to calculate the partial least square (PLS) calibration. With respect to enalapril tablets simultaneous analysis by HPLC, according to USP 26 was carried out. It was investigated if such methods allow a determination of active ingredients in tablets within limits of +/- 10% of declaration. It was shown that it is possible to set up calibration models to quantify active ingredients in tablets independent of adjuvants or optical appearance. Additionally it could be shown that NIR-spectroscopy is also applicable to determine the concentration of active ingredients in blister-packed tablets.

  1. Predicting pork quality using Vis/NIR spectroscopy.

    Science.gov (United States)

    Balage, Juliana Monteiro; da Luz E Silva, Saulo; Gomide, Catarina Abdalla; Bonin, Marina de Nadai; Figueira, Ana Cristina

    2015-10-01

    Visible and near-infrared reflectance spectroscopy (Vis/NIRS) was used to predict the ultimate pH (pHu), color, intramuscular fat (IMF) and shear force (WBSF) of pork samples and to build classifiers capable of categorizing the samples by tenderness (tender or tough) and juiciness (juicy and dry). Spectra were collected from 400 to 1495nm, and 200 data points were generated for every sample (n=134). Sixty-seven percent of the sample set was used for calibration, and 33% was used for validation. Partial least squares (PLS) calibration models were developed for each characteristic measured. A coefficient of determination (R(2)) and residual prediction deviation (RPD) were used to evaluate the accuracy of the calibration models. The pHu and color prediction models developed in this study fit this classification, indicating that these predictive models can be used to predict quality traits of intact pork samples. The Vis/NIRS offered great potential for correctly classifying pork Longissimus into two tenderness and two juiciness classes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. VIS/NIR imaging application for honey floral origin determination

    Science.gov (United States)

    Minaei, Saeid; Shafiee, Sahameh; Polder, Gerrit; Moghadam-Charkari, Nasrolah; van Ruth, Saskia; Barzegar, Mohsen; Zahiri, Javad; Alewijn, Martin; Kuś, Piotr M.

    2017-11-01

    Nondestructive methods are of utmost importance for honey characterization. This study investigates the potential application of VIS-NIR hyperspectral imaging for detection of honey flower origin using machine learning techniques. Hyperspectral images of 52 honey samples were taken in transmittance mode in the visible/near infrared (VIS-NIR) range (400-1000 nm). Three different machine learning algorithms were implemented to predict honey floral origin using honey spectral images. These methods, included radial basis function (RBF) network, support vector machine (SVM), and random forest (RF). Principal component analysis (PCA) was also exploited for dimensionality reduction. According to the obtained results, the best classifier (RBF) achieved a precision of 94% in a fivefold cross validation experiment using only the first two PCs. Mapping of the classifier results to the test set images showed 90% accuracy for honey images. Three types of honey including buckwheat, rapeseed and heather were classified with 100% accuracy. The proposed approach has great potential for honey floral origin detection. As some other honey properties can also be predicted using image features, in addition to floral origin detection, this method may be applied to predict other honey characteristics.

  3. Use of FT-NIR Spectroscopy for Bovine Colostrum Analysis

    Directory of Open Access Journals (Sweden)

    P. Navrátilová

    2006-01-01

    Full Text Available Fourier transformation near infrared spectroscopy (FT-NIR in combination with partial least squares (PLS method were used to determine the content of total solids, fat, non-fatty solids, lactose and proteins in bovine colostrum. Spectra of 90 samples were measured in the reflectance mode with a transflectance cuvette in the 10000-4000 cm-1 spectral ranges with 100 scans. Calibration was performed and statistical values of correlation coefficients (R and standard error of calibration values (SEC were computed for total solids (0.986 and 0.919, respectively, fat (0.997 and 0.285, respectively, non-fatty solids (0.995 and 0.451, respectively, lactose (0.934 and 0.285, respectively and protein (0.999 and 0.149, respectively. The calibration models developed were verified by cross validation. It follows from the study that FT-NIR spectroscopy can be used to determine the components of bovine colostrum.

  4. NIR-light triggered delivery of macromolecules into the cytosol.

    Science.gov (United States)

    Carregal-Romero, Susana; Ochs, Markus; Rivera-Gil, Pilar; Ganas, Carolin; Pavlov, Anton M; Sukhorukov, Gleb B; Parak, Wolfgang J

    2012-04-10

    Light-responsive microcapsules constructed by layer-by-layer self-assembly are used as microcarriers to deliver different macromolecules inside cells. The microcapsules carry the macromolecules as cargo in their cavity, while their walls are modified with agglomerated gold nanoparticles. Microcapsules are incorporated by living cells and are then located in lysosomal compartments. Controlled release of the encapsulated material from the interior of the capsule to the cytosol is possible upon NIR-light irradiation. This is based on local heating of the gold nanoparticles upon NIR light and disruption of the capsule wall, what results on release of encapsulated materials. We illustrate several key advances in controlled release induced by light. First, we demonstrate that capsules can be opened individually, which allows for sequentially releasing cargo from different capsules within one single cell. Second, by using a pH-indicator as cargo the claim of release from the acidic lysosomal compartments to the neutral cytosol is experimentally evident which until now has been only speculated. Third, green fluorescent protein (GFP) is released to the cytosol while retaining its functionality. This demonstrates that proteins can be released without destruction by the local heating. Fourth, GFP is also administered in biodegradable capsules, which leads to a different release mechanism compared to externally triggering for light-responsive microcapsules. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Probing Shock Compressed Silicon Metallization using VIS/NIR Reflectivity

    Science.gov (United States)

    Ali, S. J.; Bolme, C.; Jeanloz, R.; Collins, G. W.

    2013-12-01

    Broadband reflectivity measurements provide detailed information about the optical and electronic properties of shocked matter, complementing other spectroscopic techniques and increasing the accuracy of pyrometric measurements, which is vital for improving models of planetary cores. A time resolved broadband VIS/NIR reflectivity diagnostic was constructed and used to observe the metallization of shock compressed single crystal silicon phase at Jupiter Laser Facility at Lawrence Livermore National Lab. Silicon is the second most abundant element in the Earth's crust and was considered to be an excellent candidate for initial testing of this diagnostic due to accessible phase changes that should result in dramatic increases in reflectivity. A 50-100 fs 800 nm pulse was first sent through a pulse stacker and then an intense white light pulse with wavelengths from ~400 nm to ~1200 nm was generated by focusing the stacked pulses into a water cell. The white light pulses were then sent into the chamber and reflected from the target surface. The reflected light was dispersed using a custom spectrometer which was coupled to a streak camera. On transition to the higher pressure phase a dramatic increase in reflectivity was observed in the NIR, and to a lesser extent in the visible. This is congruent with the decrease in resistivity that accompanies closure of the silicon band gap and metallization.

  6. Miniature near-infrared (NIR) spectrometer engine for handheld applications

    Science.gov (United States)

    O'Brien, Nada A.; Hulse, Charles A.; Friedrich, Donald M.; Van Milligen, Fred J.; von Gunten, Marc K.; Pfeifer, Frank; Siesler, Heinz W.

    2012-06-01

    While substantial progress has been made recently towards the miniaturization of Raman, mid-infrared (IR), and near-infrared (NIR) spectrometers, there remains continued interest from end-users and product developers in pushing the technology envelope toward even smaller and lower cost analyzers. The potential of these instruments to revolutionize on-site and on-line applications can only be realized if the reduction in size does not compromise performance of the spectrometer beyond the practical need of a given application. In this paper, the working principle of a novel, extremely miniaturized NIR spectrometer will be presented. The ultra-compact spectrometer relies on thin-film linear variable filter (LVF) technology for the light dispersing element. We will also report on an environmental study whereby the contamination of soil by oil is determined quantitatively in the range of 0-12% by weight of oil contamination. The achieved analytical results will be discussed in terms of the instrument's competitiveness and suitability for on-site and in-the-field measurements.

  7. NIR photoacoustic spectroscopy for non-invasive glucose measurement.

    Science.gov (United States)

    Pai, Praful P; Kumar Sanki, Pradyut; De, Arijit; Banerjee, Swapna

    2015-08-01

    The use of near infra red (NIR) photoacoustic spectroscopy (PAS) for continuous non-invasive glucose measurement is outlined in the paper. A photoacoustic (PA) measurement apparatus was constructed and PA measurements were made on glucose solutions at multiple NIR excitation wavelengths. A variety of time and frequency domain features, including amplitude and area based features, were extracted from the PA measurements. These features were observed to be proportional to the glucose concentration of the sample. PA measurements from samples of whole blood at different glucose concentrations showed similar results. Subsequently, in vivo PA measurements made on a cohort of 30 volunteers were calibrated using a quadratic fit, and the results were compared to reference glucose concentrations made using a regular blood glucose meter. A comparison of 196 measurement pairs of predicted and reference glucose concentrations using a Clarke Error Grid gave a point distribution of 87.24% and 12.76% over zones A and B of the grid, with no measurement pairs falling in unacceptable zones C-E of the error grid. The predicted measurements had a mean absolute difference (MAD) of 12.57 ± 13.90 mg/dl and a mean absolute relative difference (MARD) of 9.61% ± 10.55%. This is an improvement over previous results obtained using PAS and other non-invasive techniques, validating the potential of PAS for continuous noninvasive glucose monitoring.

  8. Infrared and NIR Raman spectroscopy in medical microbiology

    Science.gov (United States)

    Naumann, Dieter

    1998-04-01

    FTIR and FT-NIR Raman spectra of intact microbial cells are highly specific, fingerprint-like signatures which can be used to (i) discriminate between diverse microbial species and strains, (ii) detect in situ intracellular components or structures such as inclusion bodies, storage materials or endospores, (iii) detect and quantify metabolically released CO2 in response to various different substrate, and (iv) characterize growth-dependent phenomena and cell-drug interactions. The characteristic information is extracted from the spectral contours by applying resolution enhancement techniques, difference spectroscopy, and pattern recognition methods such as factor-, cluster-, linear discriminant analysis, and artificial neural networks. Particularly interesting applications arise by means of a light microscope coupled to the spectrometer. FTIR spectra of micro-colonies containing less than 103 cells can be obtained from colony replica by a stamping technique that transfers micro-colonies growing on culture plates to a special IR-sample holder. Using a computer controlled x, y- stage together with mapping and video techniques, the fundamental tasks of microbiological analysis, namely detection, enumeration, and differentiation of micro- organisms can be integrated in one single apparatus. FTIR and NIR-FT-Raman spectroscopy can also be used in tandem to characterize medically important microorganisms. Currently novel methodologies are tested to take advantage of the complementary information of IR and Raman spectra. Representative examples on medically important microorganisms will be given that highlight the new possibilities of vibrational spectroscopies.

  9. Base excision repair activities differ in human lung cancer cells and corresponding normal controls

    DEFF Research Database (Denmark)

    Karahalil, Bensu; Bohr, Vilhelm A; De Souza-Pinto, Nadja C

    2010-01-01

    for the repair of oxidized modifications both in nuclear and mitochondrial DNA. In order to ascertain whether diminished BER capacity might account for increased levels of oxidative DNA damage in cancer cells, the activities of BER enzymes in three different lung cancer cell lines and their non...... cell lines used. However, the specific activities and cancer versus control comparison differed significantly between the nuclear and mitochondrial compartments. OGG1 activity, as measured by 8-oxodA incision, was up-regulated in cancer cell mitochondria but down-regulated in the nucleus when compared...

  10. N-Butyrate alters chromatin accessibility to DNA repair enzymes

    International Nuclear Information System (INIS)

    Smith, P.J.

    1986-01-01

    Current evidence suggests that the complex nature of mammalian chromatin can result in the concealment of DNA damage from repair enzymes and their co-factors. Recently it has been proposed that the acetylation of histone proteins in chromatin may provide a surveillance system whereby damaged regions of DNA become exposed due to changes in chromatin accessibility. This hypothesis has been tested by: (i) using n-butyrate to induce hyperacetylation in human adenocarcinoma (HT29) cells; (ii) monitoring the enzymatic accessibility of chromatin in permeabilised cells; (iii) measuring u.v. repair-associated nicking of DNA in intact cells and (iv) determining the effects of n-butyrate on cellular sensitivity to DNA damaging agents. The results indicate that the accessibility of chromatin to Micrococcus luteus u.v. endonuclease is enhanced by greater than 2-fold in n-butyrate-treated cells and that there is a corresponding increase in u.v. repair incision rates in intact cells exposed to the drug. Non-toxic levels of n-butyrate induce a block to G1 phase transit and there is a significant growth delay on removal of the drug. Resistance of HT29 cells to u.v.-radiation and adriamycin is enhanced in n-butyrate-treated cells whereas X-ray sensitivity is increased. Although changes in the responses of cells to DNA damaging agents must be considered in relation to the effects of n-butyrate on growth rate and cell-cycle distribution, the results are not inconsistent with the proposal that increased enzymatic-accessibility/repair is biologically favourable for the resistance of cells to u.v.-radiation damage. Overall the results support the suggested operation of a histone acetylation-based chromatin surveillance system in human cells

  11. Characterization of oxidative guanine damage and repair in mammalian telomeres.

    Directory of Open Access Journals (Sweden)

    Zhilong Wang

    2010-05-01

    Full Text Available 8-oxo-7,8-dihydroguanine (8-oxoG and 2,6-diamino-4-hydroxy-5-formamidopyrimidine (FapyG are among the most common oxidative DNA lesions and are substrates for 8-oxoguanine DNA glycosylase (OGG1-initiated DNA base excision repair (BER. Mammalian telomeres consist of triple guanine repeats and are subject to oxidative guanine damage. Here, we investigated the impact of oxidative guanine damage and its repair by OGG1 on telomere integrity in mice. The mouse cells were analyzed for telomere integrity by telomere quantitative fluorescence in situ hybridization (telomere-FISH, by chromosome orientation-FISH (CO-FISH, and by indirect immunofluorescence in combination with telomere-FISH and for oxidative base lesions by Fpg-incision/Southern blot assay. In comparison to the wild type, telomere lengthening was observed in Ogg1 null (Ogg1(-/- mouse tissues and primary embryonic fibroblasts (MEFs cultivated in hypoxia condition (3% oxygen, whereas telomere shortening was detected in Ogg1(-/- mouse hematopoietic cells and primary MEFs cultivated in normoxia condition (20% oxygen or in the presence of an oxidant. In addition, telomere length abnormalities were accompanied by altered telomere sister chromatid exchanges, increased telomere single- and double-strand breaks, and preferential telomere lagging- or G-strand losses in Ogg1(-/- mouse cells. Oxidative guanine lesions were increased in telomeres in Ogg1(-/- mice with aging and primary MEFs cultivated in 20% oxygen. Furthermore, oxidative guanine lesions persisted at high level in Ogg1(-/- MEFs after acute exposure to hydrogen peroxide, while they rapidly returned to basal level in wild-type MEFs. These findings indicate that oxidative guanine damage can arise in telomeres where it affects length homeostasis, recombination, DNA replication, and DNA breakage repair. Our studies demonstrate that BER pathway is required in repairing oxidative guanine damage in telomeres and maintaining telomere integrity

  12. Differential effects of procaine and phenethyl alcohol on excision repair of DNA in u.v.-irradiated Escherichia coli

    International Nuclear Information System (INIS)

    Tomiyama, H.; Tachibana, A.; Yonei, S.

    1986-01-01

    Experiments were performed to investigate the involvement of the cell membrane in the excision DNA repair process in Escherichia coli. Two membrane-binding drugs, procaine and phenethyl alcohol (PEA), inhibited liquid-holding recovery (LBR) in u.v.-irradiated E. coli wild-type and recA strains. In uvrB and polA strains where, after u.v.-irradiation, LHR was absent the two drugs had no effect. Both drugs markedly reduced the removal of u.v.-induced thymine dimers in the DNA of wild-type cells (H/r30). Analysis by alkaline sucrose gradients revealed that PEA inhibited the incision step in excision repair. In contrast, procaine had no effect on incision but apparently inhibited the late steps in excision repair. PEA dissociated DNA from the cell membrane, whereas procaine did not. The results suggest that the two drugs PEA and procaine inhibit LHR and the excision repair process operating on u.v.-induced damage in E. coli by at least two different mechanisms each of which may involve the cell membrane. (author)

  13. Nuclear-Targeting Gold Nanorods for Extremely Low NIR Activated Photothermal Therapy.

    Science.gov (United States)

    Pan, Limin; Liu, Jianan; Shi, Jianlin

    2017-05-17

    Photorelated nanomedicine is of particular interest as an emerging paradigm toward precise cancer therapy, as demonstrated by recent developments of photothermal therapy (PTT), an emerging technique employing light-converting agents to burn cancerous cells by overdosed optical energy-converted heat. However, most of the laser irradiations needed for effective PTT significantly exceed the maximal permissible power density in human skin, which is likely to damage surrounding normal tissues. Herein, we report a strategy of intranuclear PTT of cancer enabled by nuclear-targeted delivery of gold nanorods of ∼10.5 × 40.5 nm in size via conjugation with nuclear location signal peptides (GNRs-NLS) under an extremely low near-infrared irradiation of 0.2 W/cm 2 , much below the maximal permissible exposure of skin. Interestingly, we found that a mild but nuclear-focused temperature increase generated by GNRs-NLS is sufficient to cause damage to intranuclear DNA and the inhibition of DNA repair process, which, interestingly, led to the cancer cell apoptosis rather than to conventional cell necrosis by thermal ablation during PTT. Correspondingly, tumors treated with GNRs-NLS exhibited gradual but significant regressions rather than traditional harsh burning-up of tumors, in comparison with negligible antitumor effect by GNRs without nuclear targeting under the same ultralow NIR irradiation. This report demonstrates the successful intranuclear efficient photothermal therapy of cancer via cell apoptosis by photoadsorbing agents, e.g., GNRs-NLS in the present case, with largely mitigated side-effect on normal tissues and therefore substantially improved biosafety.

  14. Endoscope-assisted intraoral removal of the thyroid isthmus mass using a frenotomy incision.

    Science.gov (United States)

    Woo, Seung Hoon

    2013-09-01

    A thyroid isthmus nodule is a relatively rare condition. A small number of patients will present with thyroid mass isolated at the thyroid isthmus, which can cause discomfort in swallowing and cosmetic problems. Thus, some patients choose to have these nodules excised. The surgical removal of the thyroid isthmus mass is usually accomplished through an external incision of the neck. However, this procedure inevitably results in a neck scar. We report a case of an 18-year-old woman with a thyroid isthmus mass. We implemented a modified approach for the removal of the thyroid isthmus mass by using a frenotomy incision of the mouth, accompanied by an endoscope system. A modified approach for the removal of the thyroid isthmus mass was used on the patient. The total operating time was 70 minutes. The patient continues to be free of any diseases 12 months after the excision. Resection of the thyroid isthmus mass can be performed by an intraoral endoscope-assisted approach through a frenotomy incision of the mouth. We described the detailed procedures for an endoscope-assisted transoral thyroid isthmus mass excision using a frenotomy incision.

  15. Intraoral removal of a thyroglossal duct cyst using a frenotomy incision.

    Science.gov (United States)

    Kim, Jin Pyeong; Park, Jung Je; Lee, Eun Jae; Woo, Seung Hoon

    2011-12-01

    Thyroglossal duct cyst (TGDC) is one of the most common causes of anterior neck swelling close to the midline. Surgical removal of a TGDC is usually accomplished through an external neck incision, including the removal of the middle part of hyoid bone and a block of tissues extending to the foramen cecum. However, this procedure inevitably results in a neck scar. We report the case of a 20-year-old woman with TGDC. We implemented a modified approach to TGDC removal through a frenotomy incision of the mouth using an endoscope system. The patient received a modified approach to TGDC removal. The total operative time was 60 minutes. She remains free of disease 12 months after her surgery. We describe, in a single patient, a procedure in detail for endoscope-assisted transoral TGDC excision using an intraoral frenotomy incision. The advantage of this approach is the avoidance of a neck scar. Our experience with this patient indicates that resection of a TGDC appears to be feasible through a transoral endoscope-assisted approach using a frenotomy incision in the mouth. Further experience with this procedure is required.

  16. Normalized Urinary Flow at Puberty after Tubularized Incised Plate Urethroplasty for Hypospadias in Childhood.

    Science.gov (United States)

    Andersson, Marie; Doroszkiewicz, Monika; Arfwidsson, Charlotte; Abrahamsson, Kate; Sillén, Ulla; Holmdahl, Gundela

    2015-11-01

    An obstructive urinary flow pattern is frequently seen after tubularized incised plate urethroplasty for hypospadias. However, the significance of this finding has not been determined and long-term results are few. We describe postoperative long-term uroflowmetry results after puberty in males who underwent tubularized incised plate urethroplasty in childhood. A total of 126 boys underwent tubularized incised plate urethroplasty for distal penile to mid shaft hypospadias at Queen Silvia Children's Hospital in Gothenburg between 1999 and 2003. Of the patients 48 were toilet trained at surgery. We report on 40 patients who had data available at 2 and 12 months postoperatively, 7 years postoperatively and at puberty (median age 15.0 years, range 13.7 to 17.1). Of the patients 31 had distal and 9 had mid penile hypospadias. Clinical examination, urinary medical history, uroflowmetry and ultrasound measuring residual urine were performed. Maximum urinary flow was correlated to age and voided volume, using Miskolc nomograms for comparison of percentiles. At 1 year postoperatively 15 boys (37.5%) had normal urinary flow (above 25th percentile), compared to 16 (40%) at 7 years and 38 (95%) at puberty (p hypospadias (p = 0.008), as well as in patients who did (p = 0.0078) and did not undergo intervention (p hypospadias treated with tubularized incised plate urethroplasty. Unless symptoms occur, a conservative approach seems preferable. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. The Evolution of the Appendectomy: From Open to Laparoscopic to Single Incision

    Directory of Open Access Journals (Sweden)

    Noah J. Switzer

    2012-01-01

    Full Text Available Beginning with its initial description by Fitz in the 19th century, acute appendicitis has been a significant long-standing medical challenge; today it remains the most common gastrointestinal emergency in adults. Already in 1894, McBurney advocated for the surgical removal of the inflamed appendix and is credited with the initial description of an Open Appendectomy (OA. With the introduction of minimally invasive surgery, this classic approach evolved into a procedure with multiple, smaller incisions; a technique termed Laparoscopic Appendectomy (LA. There is much literature describing the advantages of this newer approach. To name a few, patients have significantly less wound infections, reduced pain, and a reduction in ileus compared with the OA. In the past few years, Single Incision Laparoscopic Appendectomy (SILA has gained popularity as the next major evolutionary advancement in the removal of the appendix. Described as a pioneer in the era of “scarless surgery,” it involves only one transumbilical incision. Patients are postulated to have reduced post-operative complications such as infection, hernias, and hematomas, as well as a quicker recovery time and less post-operative pain scores, in comparison to its predecessors. In this review, we explore the advancement of the appendectomy from open to laparoscopic to single incision.

  18. Outcomes of single-stage total arch replacement via clamshell incision

    Directory of Open Access Journals (Sweden)

    Ishizaka Toru

    2011-09-01

    Full Text Available Abstract Background Treatment of complex aortic pathologies involving the transverse arch with extensive involvement of the descending aorta remains a surgical challenge. Since clamshell incision provides superior exposure of the entire thoracic aorta, we evaluated the use of this technique for single-stage total arch replacement by arch vessel reconstruction. Methods The arch-first technique combined with clamshell incision was used in 38 cases of aneurysm and aortic disease in 2008 and 2009. Extensive total arch replacement was used with clamshell incision for reconstruction of arch vessels under deep hypothermic circulatory arrest. Results Overall 30-day mortality was 13%. The mean operating time was approximately 8 hours. Deep hypothermia resulted in mean CPB time exceeding 4.5 hours and mean duration of circulatory arrest was 25 minutes. The overall postoperative temporary and permanent neurologic dysfunction rates were 3% and 3% for elective and 3% and 0% for emergency surgery, respectively. All patients except the five who died in hospital were discharged without nursing care after an average post-operative hospital stay of 35 days. Conclusions The arch-first technique, combined with clamshell incision, provides expeditious replacement of the thoracic aorta with an acceptable duration of hypothermic circulatory arrest and minimizes the risk of retrograde atheroembolism by using antegrade perfusion.

  19. Two-incision minimally invasive total hip arthroplasty - results and complications

    NARCIS (Netherlands)

    van Oldenrijk, Jakob; Hoogervorst, Paul; Schaap, Gerard R.; van Dijk, C. Niek; Schafroth, Matthias U.

    2011-01-01

    The purpose of this study was to determine the complication rate and functional result after two-incision minimally invasive total hip arthroplasty in a retrospective consecutive case series of the first 45 patients treated by a single surgeon. The mean follow up period was 2.1 years. There were 4

  20. Computed tomography contrast media extravasation: treatment algorithm and immediate treatment by squeezing with multiple slit incisions.

    Science.gov (United States)

    Kim, Sue Min; Cook, Kyung Hoon; Lee, Il Jae; Park, Dong Ha; Park, Myong Chul

    2017-04-01

    In our hospital, an adverse event reporting system was initiated that alerts the plastic surgery department immediately after suspecting contrast media extravasation injury. This system is particularly important for a large volume of extravasation during power injector use. Between March 2011 and May 2015, a retrospective chart review was performed on all patients experiencing contrast media extravasation while being treated at our hospital. Immediate treatment by squeezing with multiple slit incisions was conducted for a portion of these patients. Eighty cases of extravasation were reported from approximately 218 000 computed tomography scans. The expected extravasation volume was larger than 50 ml, or severe pressure was felt on the affected limb in 23 patients. They were treated with multiple slit incisions followed by squeezing. Oedema of the affected limb disappeared after 1-2 hours after treatment, and the skin incisions healed within a week. We propose a set of guidelines for the initial management of contrast media extravasation injuries for a timely intervention. For large-volume extravasation cases, immediate management with multiple slit incisions is safe and effective in reducing the swelling quickly, preventing patient discomfort and decreasing skin and soft tissue problems. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  1. Forensic aspects of incised wounds and bruises in pigs established post-mortem.

    Science.gov (United States)

    Barington, Kristiane; Jensen, Henrik Elvang

    2017-06-01

    Recognizing post-mortem (PM) changes is of crucial importance in veterinary forensic pathology. In porcine wounds established PM contradicting observations regarding infiltration of leukocytes have been described. In the present study, skin, subcutis and muscle tissue sampled from experimental pigs with PM incised wounds (n=8), PM bruises (n=8) and no lesions, i.e. controls (n=4), were examined for signs of vitality over time. All tissue samples were subjected to gross and histopathological evaluation. Hemorrhages were present along the edges of PM incised wounds but deposits of fibrin were never observed. PM bruise led to hemorrhage in the subcutis visible on cross section of the skin in 3 out of 8 pigs. Histologically, hemorrhages in the subcutaneous tissue and disrupted muscle fibers were observed in PM bruises and could not be differentiated from similar lesions in ante-mortem (AM) bruises. Vital reactions, i.e. infiltrating leukocytes, hyper-leukocytosis and pavement of leukocytes, were absent in all incised wounds and bruises regardless of the time of sampling after traumatization. In conclusion, a vital reaction was not present in PM incised wounds, regardless of the time of sampling. Moreover, it was found that AM bruises free of leukocyte infiltration cannot be distinguished from PM bruises, an observation which is of crucial importance when timing bruises in forensic cases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Holocene valley-floor deposition and incision in a small drainage basin in western Colorado, USA

    Science.gov (United States)

    Jones, Lawrence S.; Rosenburg, Margaret; Figueroa, Maria del Mar; McKee, Kathleen; Haravitch, Ben; Hunter, Jenna

    2010-09-01

    The valley floor of a 33.9 km 2 watershed in western Colorado experienced gradual sedimentation from before ˜ 6765 to ˜ 500 cal yr BP followed by deep incision, renewed aggradation, and secondary incision. In contrast, at least four terraces and widespread cut-and-fill architecture in the valley floor downstream indicate multiple episodes of incision and deposition occurred during the same time interval. The upper valley fill history is atypical compared to other drainages in the Colorado Plateau. One possible reason for these differences is that a bedrock canyon between the upper and lower valley prevented headward erosion from reaching the upper valley fill. Another possibility is that widespread, sand-rich, clay-poor lithologies in the upper drainage limited surface runoff and generally favored alluviation, whereas more clay-rich lithologies in the lower drainage resulted in increased surface runoff and more frequent incision. Twenty-two dates from valley fill charcoal indicate an approximate forest fire recurrence interval of several hundred years, similar to that from other studies in juniper-piñon woodlands. Results show that closely spaced vertical sampling of alluvium in headwater valleys where linkages between hillslope processes and fluvial activity are relatively direct can provide insight about the role of fires in alluvial chronologies of semi-arid watersheds.

  3. Effects of Bank Vegetation and Incision on Erosion Rates in an Urban Stream

    Directory of Open Access Journals (Sweden)

    Emily Arnold

    2018-04-01

    Full Text Available Changing land-use associated with urbanization has resulted in shifts in riparian assemblages, stream hydraulics, and sediment dynamics leading to the degradation of waterways. To combat degradation, restoration and management of riparian zones is becoming increasingly common. However, the relationship between flora, especially the influence of invasive species, on sediment dynamics is poorly understood. Bank erosion and turbidity were monitored in the Tookany Creek and its tributary Mill Run in the greater Philadelphia, PA region. To evaluate the influence of the invasive species Reynoutria japonica (Japanese knotweed on erosion, reaches were chosen based on their riparian vegetation and degree of incision. Bank pins and turbidity loggers were used to estimate sediment erosion. Erosion calculations based on bank pins suggest greater erosion in reaches dominated by knotweed than those dominated by trees. For a 9.5-month monitoring period, there was 29 cm more erosion on banks that were also incised, and 9 cm more erosion in banks with little incision. Turbidity responses to storm events were also higher (77 vs. 54 NTU (nephelometric turbidity unit in reaches with knotweed, although this increase was found when the reach dominated by knotweed was also incised. Thus, this study linked knotweed to increased erosion using multiple methods.

  4. Carpal tunnel release using the radial sided approach compared with the two-incision approach.

    Science.gov (United States)

    Calleja, Henry; Tsai, Tsu-Min; Kaufman, Christina

    2014-01-01

    We compared carpal tunnel release using a radial sided approach (RCTR) with a two-incision approach with regards to complications, grip strength, and functional outcomes. Retrospective chart review was done and data was collected pre-operatively, and post-operatively at six weeks and three months. A total of 32 and 26 patients were included in the two-incision and RCTR groups respectively. At six weeks, the RCTR group showed an increased grip strength (+32.24%) while the two-incision group was weaker (-6.75%). Both groups showed an increased strength at three months, RCTR at 98.4% while the two-incision group was significantly lower at 38.6% increase. Both techniques provided improvement in outcome scores, with no statistical difference. RCTR was associated with a significantly earlier return of grip strength and had better grip strength at six weeks and three months post-operatively. Both techniques provided symptom relief and good functional outcome.

  5. Seismic evidence of glacial-age river incision into the Tahaa barrier reef, French Polynesia

    Science.gov (United States)

    Toomey, Michael; Woodruff, Jonathan D.; Ashton, Andrew D.; Perron, J. Taylor

    2016-01-01

    Rivers have long been recognized for their ability to shape reef-bound volcanic islands. On the time-scale of glacial–interglacial sea-level cycles, fluvial incision of exposed barrier reef lagoons may compete with constructional coral growth to shape the coastal geomorphology of ocean islands. However, overprinting of Pleistocene landscapes by Holocene erosion or sedimentation has largely obscured the role lowstand river incision may have played in developing the deep lagoons typical of modern barrier reefs. Here we use high-resolution seismic imagery and core stratigraphy to examine how erosion and/or deposition by upland drainage networks has shaped coastal morphology on Tahaa, a barrier reef-bound island located along the Society Islands hotspot chain in French Polynesia. At Tahaa, we find that many channels, incised into the lagoon floor during Pleistocene sea-level lowstands, are located near the mouths of upstream terrestrial drainages. Steeper antecedent topography appears to have enhanced lowstand fluvial erosion along Tahaa's southwestern coast and maintained a deep pass. During highstands, upland drainages appear to contribute little sediment to refilling accommodation space in the lagoon. Rather, the flushing of fine carbonate sediment out of incised fluvial channels by storms and currents appears to have limited lagoonal infilling and further reinforced development of deep barrier reef lagoons during periods of highstand submersion.

  6. Single-incision sleeve gastrectomy versus conventional laparoscopic sleeve gastrectomy--a randomised pilot study.

    Science.gov (United States)

    Lakdawala, Muffazal A; Muda, Nor Hisham; Goel, Sunita; Bhasker, Aparna

    2011-11-01

    This is a prospective pilot study done to evaluate the feasibility and to assess the outcomes and complication rates of the single-incision sleeve gastrectomy versus the conventional five-port laparoscopic sleeve gastrectomy. A prospective comparative analysis was done of 50 patients in each arm who underwent laparoscopic sleeve gastrectomy and single-incision sleeve gastrectomy from September 2009 until April 2010. Both groups were matched for age, gender and BMI and were then randomly assigned to either group. Postoperative pain scoring was done using the visual analogue scale. Postoperative outcomes in terms of pain scores, excess weight loss, resolution of comorbidities and complication rates were compared in both groups, at the end of 6 months. Operating times in both groups were comparable with experience. Intraoperative blood loss was similar in both groups. VAS scoring revealed lesser postoperative pain after the first 8 h in the single-incision group as compared to the laparoscopy group-P < 0.0001. At 6 months, excess weight loss and resolution of comorbidities were comparable in both groups. There were no major complications or mortalities in either group. Single-incision laparoscopic sleeve gastrectomy is a feasible surgical procedure for morbid obesity in selected individuals. When compared to conventional laparoscopic sleeve gastrectomy, it has equally effective weight loss and resolution of comorbidities. It also has the added benefits of little or no visible scarring and reduced postoperative pain.

  7. Quality-of-Life and Visual Function after Manual Small Incision ...

    African Journals Online (AJOL)

    Background: Outcome studies after cataract surgery should focus on functional status and quality of life instead of visual acuity measurement alone. Objective: To assess patients' quality of life (QoL) and overall visual function (VF) after manual small incision cataract surgery (SICS) with intraocular lens (IOL) implantation.

  8. Full-Thickness Retinochoroidal Incision in the Management of Central Retinal Vein Occlusion

    Directory of Open Access Journals (Sweden)

    San-Ni Chen

    2015-01-01

    Full Text Available Purpose. To evaluate the clinical outcomes in patients with central retinal vein occlusion (CRVO treated with full-thickness retinochoroidal incisions and to compare whether there is difference in treatment response in ischemic and nonischemic CRVO. Methods. Retrospective study of patients of CRVO receiving full-thickness retinochoroidal incisions in Changhua Christian Hospital. Fluorescein angiography (FA, slit-lamp biomicroscopy, indirect funduscopy, best corrected visual acuity, and central macular thickness (CMT measured by optical coherence tomography were performed pre- and postoperatively. Patients were divided into an ischemic and nonischemic group according to the findings of FA. Patients were followed up for at least 1 year. Results. Twenty-eight eyes (14 ischemic and 14 nonischemic CRVO were included. Functional retinochoroidal venous anastomosis (RCVA was achieved in 48 of the 65 retinochoroidal incisions (73.8%. Central macular thickness (CMT and retinal hemorrhage decreased significantly after the surgery. Significant visual gain was observed postoperatively in the nonischemic group, but not in the ischemic group. Postoperative complications included vitreous hemorrhage (17.8%, neovascular glaucoma (7.1%, and preretinal fibrovasular membrane (10.7%, all of which were in the ischemic group. Conclusions. RCVA formation induced by retinochoroidal incisions could improve venous flow, and decrease CMT and retinal hemorrhage. However, only eyes with nonischemic CRVO showed visual improvement.

  9. Gene Therapy for Cartilage Repair

    Science.gov (United States)

    Madry, Henning; Orth, Patrick; Cucchiarini, Magali

    2011-01-01

    The concept of using gene transfer strategies for cartilage repair originates from the idea of transferring genes encoding therapeutic factors into the repair tissue, resulting in a temporarily and spatially defined delivery of therapeutic molecules to sites of cartilage damage. This review focuses on the potential benefits of using gene therapy approaches for the repair of articular cartilage and meniscal fibrocartilage, including articular cartilage defects resulting from acute trauma, osteochondritis dissecans, osteonecrosis, and osteoarthritis. Possible applications for meniscal repair comprise meniscal lesions, meniscal sutures, and meniscal transplantation. Recent studies in both small and large animal models have demonstrated the applicability of gene-based approaches for cartilage repair. Chondrogenic pathways were stimulated in the repair tissue and in osteoarthritic cartilage using genes for polypeptide growth factors and transcription factors. Although encouraging data have been generated, a successful translation of gene therapy for cartilage repair will require an ongoing combined effort of orthopedic surgeons and of basic scientists. PMID:26069580

  10. DNA repair deficiency in neurodegeneration

    DEFF Research Database (Denmark)

    Jeppesen, Dennis Kjølhede; Bohr, Vilhelm A; Stevnsner, Tinna V.

    2011-01-01

    Deficiency in repair of nuclear and mitochondrial DNA damage has been linked to several neurodegenerative disorders. Many recent experimental results indicate that the post-mitotic neurons are particularly prone to accumulation of unrepaired DNA lesions potentially leading to progressive...... neurodegeneration. Nucleotide excision repair is the cellular pathway responsible for removing helix-distorting DNA damage and deficiency in such repair is found in a number of diseases with neurodegenerative phenotypes, including Xeroderma Pigmentosum and Cockayne syndrome. The main pathway for repairing oxidative...... base lesions is base excision repair, and such repair is crucial for neurons given their high rates of oxygen metabolism. Mismatch repair corrects base mispairs generated during replication and evidence indicates that oxidative DNA damage can cause this pathway to expand trinucleotide repeats, thereby...

  11. Safety and feasibility of single-incision laparoscopic cholecystectomy in obese patients

    Directory of Open Access Journals (Sweden)

    Masaki Wakasugi

    2017-01-01

    Full Text Available Current literature frequently indicates that experienced laparoscopic surgeons can safely perform single-incision laparoscopic cholecystectomy, but there have been few reports evaluating the feasibility and safety of performing single-incision laparoscopic cholecystectomy for obese patients. Therefore, a large single-center database was retrospectively reviewed to evaluate the feasibility and safety of single-incision laparoscopic cholecystectomy for obese patients by comparing the outcomes of normal-weight and obese patients undergoing single-incision laparoscopic cholecystectomy.A retrospective analysis of 608 patients undergoing SILC between May 2009 and May 2015 at Osaka Police Hospital was performed, and the outcomes of obese [body mass index (BMI ≥ 30 kg/m2] and normal-weight patients (18.5 ≤ BMI < 25 kg/m2 were compared.Thirty-eight obese patients (mean BMI 32.5 kg/m2 were compared to 362 normal-weight patients (mean BMI 22.0 kg/m2. The American Society of Anesthesiologists (ASA scores of the obese patients were significantly higher than those of normal-weight patients. The mean operative times in the normal-weight and the obese groups were 110 min vs. 127 min, respectively (p < 0.05. There were no significant differences in the bleeding volume and the conversion rate to a different operative procedure. Perioperative complications were seen in 6% (23/362 of the patients in the normal-weight group and 8% (3/38 of the patients in the obese group (p = 0.7. The mean postoperative hospital stay was 4.5 days for the normal-weight group and 4.4 days for the obese group (p = 0.8.Single-incision laparoscopic cholecystectomy, which offers good cosmetic outcomes, seems feasible and safe in obese patients.•Single-incision laparoscopic cholecystectomy offers good cosmetic outcomes.•Single-incision laparoscopic cholecystectomy seems feasible and safe in obese patients.

  12. New constraints on the late Cenozoic incision history of the New River, Virginia

    Science.gov (United States)

    Ward, Dylan J.; Spotila, James A.; Hancock, Gregory S.; Galbraith, John M.

    2005-12-01

    The New River crosses three physiogeologic provinces of the ancient, tectonically quiescent Appalachian orogen and is ideally situated to record variability in fluvial erosion rates over the late Cenozoic. Active erosion features on resistant bedrock that floors the river at prominent knickpoints demonstrate that the river is currently incising toward base level. However, thick sequences of alluvial fill and fluvial terraces cut into this fill record an incision history for the river that includes several periods of stalled downcutting and aggradation. We used cosmogenic 10Be exposure dating, aided by mapping and sedimentological examination of terrace deposits, to constrain the timing of events in this history. 10Be concentration depth profiles were used to help account for variables such as cosmogenic inheritance and terrace bioturbation. Fill-cut and strath terraces at elevations 10, 20, and 50 m above the modern river yield model cosmogenic exposure ages of 130, ˜600, and 600-950 ka, respectively, but uncertainties on these ages are not well constrained. These results provide the first direct constraint on the history of alluvial aggradation and incision events recorded by New River terrace deposits. The exposure ages yield a long-term average incision rate of 43 m/my, which is comparable to rates measured elsewhere in the Appalachians. During specific intervals over the last 1 Ma, however, the New River's incision rate reached ˜100 m/my. Modern erosion rates on bedrock at a prominent knickpoint are between ˜28 and ˜87 m/my, in good agreement with rates calculated between terrace abandonment events and significantly faster than ˜2 m/my rates of surface erosion from ancient terrace remnants. Fluctuations between aggradation and rapid incision operate on timescales of 10 4- 10 5 year, similar to those of late Cenozoic climate variations, though uncertainties in model ages preclude direct correlation of these fluctuations to specific climate change events

  13. European Hernia Society guidelines on the closure of abdominal wall incisions.

    Science.gov (United States)

    Muysoms, F E; Antoniou, S A; Bury, K; Campanelli, G; Conze, J; Cuccurullo, D; de Beaux, A C; Deerenberg, E B; East, B; Fortelny, R H; Gillion, J-F; Henriksen, N A; Israelsson, L; Jairam, A; Jänes, A; Jeekel, J; López-Cano, M; Miserez, M; Morales-Conde, S; Sanders, D L; Simons, M P; Śmietański, M; Venclauskas, L; Berrevoet, F

    2015-02-01

    The material and the surgical technique used to close an abdominal wall incision are important determinants of the risk of developing an incisional hernia. Optimising closure of abdominal wall incisions holds a potential to prevent patients suffering from incisional hernias and for important costs savings in health care. The European Hernia Society formed a Guidelines Development Group to provide guidelines for all surgical specialists who perform abdominal incisions in adult patients on the materials and methods used to close the abdominal wall. The guidelines were developed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach and methodological guidance was taken from Scottish Intercollegiate Guidelines Network (SIGN). The literature search included publications up to April 2014. The guidelines were written using the AGREE II instrument. An update of these guidelines is planned for 2017. For many of the Key Questions that were studied no high quality data was detected. Therefore, some strong recommendations could be made but, for many Key Questions only weak recommendations or no recommendation could be made due to lack of sufficient evidence. To decrease the incidence of incisional hernias it is strongly recommended to utilise a non-midline approach to a laparotomy whenever possible. For elective midline incisions, it is strongly recommended to perform a continuous suturing technique and to avoid the use of rapidly absorbable sutures. It is suggested using a slowly absorbable monofilament suture in a single layer aponeurotic closure technique without separate closure of the peritoneum. A small bites technique with a suture to wound length (SL/WL) ratio at least 4/1 is the current recommended method of fascial closure. Currently, no recommendations can be given on the optimal technique to close emergency laparotomy incisions. Prophylactic mesh augmentation appears effective and safe and can be suggested in high

  14. Recovering fNIRS brain signals: physiological interference suppression with independent component analysis

    Science.gov (United States)

    Zhang, Y.; Shi, M.; Sun, J.; Yang, C.; Zhang, Yajuan; Scopesi, F.; Makobore, P.; Chin, C.; Serra, G.; Wickramasinghe, Y. A. B. D.; Rolfe, P.

    2015-02-01

    Brain activity can be monitored non-invasively by functional near-infrared spectroscopy (fNIRS), which has several advantages in comparison with other methods, such as flexibility, portability, low cost and fewer physical restrictions. However, in practice fNIRS measurements are often contaminated by physiological interference arising from cardiac contraction, breathing and blood pressure fluctuations, thereby severely limiting the utility of the method. Hence, further improvement is necessary to reduce or eliminate such interference in order that the evoked brain activity information can be extracted reliably from fNIRS data. In the present paper, the multi-distance fNIRS probe configuration has been adopted. The short-distance fNIRS measurement is treated as the virtual channel and the long-distance fNIRS measurement is treated as the measurement channel. Independent component analysis (ICA) is employed for the fNIRS recordings to separate the brain signals and the interference. Least-absolute deviation (LAD) estimator is employed to recover the brain activity signals. We also utilized Monte Carlo simulations based on a five-layer model of the adult human head to evaluate our methodology. The results demonstrate that the ICA algorithm has the potential to separate physiological interference in fNIRS data and the LAD estimator could be a useful criterion to recover the brain activity signals.

  15. The role of cell hydration in realization of biological effects of non-ionizing radiation (NIR).

    Science.gov (United States)

    Ayrapetyan, Sinerik

    2015-09-01

    The weak knowledge on the nature of cellular and molecular mechanisms of biological effects of NIR such as static magnetic field, infrasound frequency of mechanical vibration, extremely low frequency of electromagnetic fields and microwave serves as a main barrier for adequate dosimetry from the point of Public Health. The difficulty lies in the fact that the biological effects of NIR depend not only on their thermodynamic characteristics but also on their frequency and intensity "windows", chemical and physical composition of the surrounding medium, as well as on the initial metabolic state of the organism. Therefore, only biomarker can be used for adequate estimation of biological effect of NIR on organisms. Because of the absence of such biomarker(s), organizations having the mission to monitor hazardous effects of NIR traditionally base their instruction on thermodynamic characteristics of NIR. Based on the high sensitivity to NIR of both aqua medium structure and cell hydration, it is suggested that cell bathing medium is one of the primary targets and cell hydration is a biomarker for NIR effects on cells and organisms. The purpose of this article is to present a short review of literature and our own experimental data on the effects of NIR on plants' seeds germination, microbe growth and development, snail neurons and heart muscle, rat's brain and heart tissues.

  16. Single seed NIR as a fast method to predict germination ability in Pak Choi

    DEFF Research Database (Denmark)

    Gislum, René; Deleuran, Lise Christina; Olesen, Merete Halkjær

    2012-01-01

    Single seed NIR has further been tested to determine the applicability for prediction of seed viability in radish (Raphanus sativus L.) seeds and spinach (Spinacia oleracea L.) seeds. The studies show the possibility of using NIR spectroscopy in a seed separating process in the future, provided...

  17. The use of near infrared spectroscopy (NIRS) to predict the chemical ...

    African Journals Online (AJOL)

    The wet chemical analysis of feed samples is time consuming and expensive. Near infrared spectroscopy (NIRS) was developed as a rapid technique to predict the chemical composition of feeds. The prediction of accuracy of NIRS relies heavily on obtaining a calibration set which represents the variation in the main ...

  18. A New Framework for the Assessment of Cerebral Hemodynamics Regulation in Neonates Using NIRS

    NARCIS (Netherlands)

    Caicedo, Alexander; Alderliesten, Thomas; Naulaers, Gunnar; Lemmers, Petra; van Bel, Frank; Van Huffel, Sabine

    2016-01-01

    We present a new framework for the assessment of cerebral hemodynamics regulation (CHR) in neonates using near-infrared spectroscopy (NIRS). In premature infants, NIRS measurements have been used as surrogate variables for cerebral blood flow (CBF) in the assessment of cerebral autoregulation (CA).

  19. Meniscal repair: Technique.

    Science.gov (United States)

    Beaufils, P; Pujol, N

    2018-02-01

    Meniscal repair aims to achieve meniscal healing, avoiding the adverse effects of meniscectomy. Longitudinal vertical tears in a vascularized area are the reference indication. The technique generally uses hybrid all-inside implants. The outside-in technique has other indications in more anterior tears. Healing has been demonstrated on CT-arthrography and arthroscopy. Specific techniques have been developed for other pathological situations. Posterior meniscosynovial lesions in a context of chronic anterior laxity are identified by exploration of the posterior compartment, and fixed by all-inside hook suture. Horizontal lesions in young athletes can be treated by open meniscal suture. Radial tears, when deep, can be repaired. Root tears, when traumatic, can be treated by transosseous pullout reinsertion. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. Electrically Mediated Trauma Repair.

    Science.gov (United States)

    1986-03-01

    Freindenberg and Brighton (5) found such "bioelectric potentials" to be negative in articular and epiphyseal regions and in the fracture site. Conversely...LB., and H.G. Smith. 1969. "Electric potentials in intact and fractured tibia . " Clin-. Orton. 63:222-225. 7. Borgens, .B. 1982. "What is the role of...development) or regeneration (such as fracture repair and axonal elongation) In some cases we can modify the battery driving these currents by