WorldWideScience

Sample records for incision repair nir

  1. New insights in the removal of the hydantoins, oxidation product of pyrimidines, via the base excision and nucleotide incision repair pathways.

    Directory of Open Access Journals (Sweden)

    Modesto Redrejo-Rodríguez

    Full Text Available BACKGROUND: Oxidative damage to DNA, if not repaired, can be both miscoding and blocking. These genetic alterations can lead to mutations and/or cell death, which in turn cause cancer and aging. Oxidized DNA bases are substrates for two overlapping repair pathways: base excision (BER and nucleotide incision repair (NIR. Hydantoin derivatives such as 5-hydroxyhydantoin (5OH-Hyd and 5-methyl-5-hydroxyhydantoin (5OH-5Me-Hyd, major products of cytosine and thymine oxidative degradation pathways, respectively, have been detected in cancer cells and ancient DNA. Hydantoins are blocking lesions for DNA polymerases and excised by bacterial and yeast DNA glycosylases in the BER pathway. However little is known about repair of pyrimidine-derived hydantoins in human cells. METHODOLOGY/PRINCIPAL FINDINGS: Here, using both denaturing PAGE and MALDI-TOF MS analyses we report that the bacterial, yeast and human AP endonucleases can incise duplex DNA 5' next to 5OH-Hyd and 5OH-5Me-Hyd thus initiating the NIR pathway. We have fully reconstituted the NIR pathway for these lesions in vitro using purified human proteins. Depletion of Nfo in E. coli and APE1 in HeLa cells abolishes the NIR activity in cell-free extracts. Importantly, a number of redundant DNA glycosylase activities can excise hydantoin residues, including human NTH1, NEIL1 and NEIL2 and the former protein being a major DNA glycosylase activity in HeLa cells extracts. CONCLUSIONS/SIGNIFICANCE: This study demonstrates that both BER and NIR pathways can compete and/or back-up each other to remove hydantoin DNA lesions in vivo.

  2. In vitro conjunctival incision repair by temperature-controlled laser soldering.

    Science.gov (United States)

    Norman, Galia; Rabi, Yaron; Assia, Ehud; Katzir, Abraham

    2009-01-01

    The common method of closing conjunctival incisions is by suturing, which is associated with several disadvantages. It requires skill to apply and does not always provide a watertight closure, which is required in some operations (e.g., glaucoma filtration). The purpose of the present study was to evaluate laser soldering as an alternative method for closing conjunctival incisions. Conjunctival incisions of 20 ex vivo porcine eyes were laser soldered using a temperature-controlled fiberoptic laser system and an albumin mixed with indocyanine green as a solder. The control group consisted of five repaired incisions by a 10-0 nylon running suture. The leak pressure of the repaired incisions was measured. The mean leak pressure in the laser-soldered group was 132 mm Hg compared to 4 mm Hg in the sutured group. There was no statistically significant difference in both the incision's length and distance from the limbus between the groups, before and after the procedure, indicating that there was no severe thermal damage. These preliminary results clearly demonstrate that laser soldering may be a useful method for achieving an immediate watertight conjunctival wound closure. This procedure is faster and easier to apply than suturing.

  3. Coupling of the nucleotide incision and 3' {yields} 5' exonuclease activities in Escherichia coli endonuclease IV: Structural and genetic evidences

    Energy Technology Data Exchange (ETDEWEB)

    Golan, Gali [Hebrew University of Jerusalem, Jerusalem 91904 (Israel); Ishchenko, Alexander A. [Groupe Reparation de l' ADN, CNRS UMR 8126, Univ. Paris-Sud, Institut de Cancerologie Gustave Roussy, 39, rue Camille Desmoulins, F-94805 Villejuif Cedex (France); Khassenov, Bekbolat [National Center for Biotechnology, Astana (Kazakhstan); Shoham, Gil, E-mail: gil2@vms.huji.ac.il [Hebrew University of Jerusalem, Jerusalem 91904 (Israel); Saparbaev, Murat K., E-mail: smurat@igr.fr [Groupe Reparation de l' ADN, CNRS UMR 8126, Univ. Paris-Sud, Institut de Cancerologie Gustave Roussy, 39, rue Camille Desmoulins, F-94805 Villejuif Cedex (France)

    2010-03-01

    Aerobic respiration generates reactive oxygen species (ROS) as a by-product of cellular metabolism which can damage DNA. The complex nature of oxidative DNA damage requires actions of several repair pathways. Oxidized DNA bases are substrates for two overlapping pathways: base excision repair (BER) and nucleotide incision repair (NIR). In the BER pathway a DNA glycosylase cleaves the N-glycosylic bond between the abnormal base and deoxyribose, leaving either an abasic site or single-stranded DNA break. Alternatively, in the NIR pathway, an apurinic/apyrimidinic (AP) endonuclease incises duplex DNA 5' next to oxidatively damaged nucleotide. The multifunctional Escherichia coli endonuclease IV (Nfo) is involved in both BER and NIR pathways. Nfo incises duplex DNA 5' of a damaged residue but also possesses an intrinsic 3' {yields} 5' exonuclease activity. Herein, we demonstrate that Nfo-catalyzed NIR and exonuclease activities can generate a single-strand gap at the 5' side of 5,6-dihydrouracil residue. Furthermore, we show that Nfo mutants carrying amino acid substitutions H69A and G149D are deficient in both NIR and exonuclease activities, suggesting that these two functions are genetically linked and governed by the same amino acid residues. The crystal structure of Nfo-H69A mutant reveals the loss of one of the active site zinc atoms (Zn1) and rearrangements of the catalytic site, but no gross changes in the overall enzyme conformation. We hypothesize that these minor changes strongly affect the DNA binding of Nfo. Decreased affinity may lead to a different kinking angle of the DNA helix and this in turn thwart nucleotide incision and exonuclease activities of Nfo mutants but to lesser extent of their AP endonuclease function. Based on the biochemical and genetic data we propose a model where nucleotide incision coupled to 3' {yields} 5' exonuclease activity prevents formation of lethal double-strand breaks when repairing bi

  4. Minimal Incision Scar-Less Open Umbilical Hernia Repair in Adults - Technical Aspects and Short Term Results

    Directory of Open Access Journals (Sweden)

    Sanoop Koshy Zachariah

    2014-09-01

    Full Text Available Background: There is no gold standard technique for umbilical hernia repair .Conventional open umbilical hernia repair often produces an undesirable scar. Laparoscopic umbilical hernia repair requires multiple incisions beyond the umbilicus, specialized equipments, and expensive tissue separating mesh. We describe our technique of open umbilical hernia repair utilizing a small incision. The technique was derived from our experience with single incision laparoscopy. We report the technical details and short term results. Methods: This is a retrospective analysis of the first 20 patients who underwent minimal incision scar-less open umbilical hernia repair, from June 2011 to February 2014. A single intra-umbilical curved incision was used to gain access to the hernia sac. Primary suture repair was performed for defects upto 2cm.Larger defects were repaired using an onlay mesh. In patients with a BMI of 30 kg/m2 or greater, onlay mesh hernioplasty was performed irrespective of the defect size.Results: A total of 20 patients, 12 males and 8 females underwent the procedure. Mean age was 50 (range 29 - 82 years. Mean BMI was 26.27 (range 20. -33.1 kg/m2. Average size of the incision was 1.96 range (1.5 to 2.5 cm. Mesh hernioplasty was done in 9 patients. 11 patients underwent primary suture repair alone. There were no postoperative complications associated with his technique. Average post operative length of hospital stay was 3.9 (range 2-10 days. Mean follow-up was 29.94 months, (2 weeks to 2.78 years. On follow up there was no externally visible scar in any of the patients. There were no recurrences on final follow up. Conclusion: This technique provides a similar cosmetic effect as obtained from single port laparoscopy. It is easy to perform safe, offers good cosmesis, does not require incisions beyond the umbilicus and cost effective, with encouraging results on short term follow up. Further research is needed to assess the true potential of the

  5. Behaviour of UV-sensitive mutants of Proteus mirabilis to repair incision breaks

    International Nuclear Information System (INIS)

    Stoerl, K.; Mund, C.

    1977-01-01

    In U.V.-sensitive mutants of P. mirabilis with the phenotype HCR, REC and EXR single-strand breaks appeared immediately after UV-irradiation. The behaviour of REC- and EXR-mutants was similar to the wildtype. The number of incision breaks observed by sedimentation analysis in these strains was very low. They could be joined during the excision repair process. From the ability of REC- and EXR-strains to rejoin most of the induced single-strand breaks it can be concluded that these strains have approximately the same capacity for excision repair as the wildtype. HCR-mutants of P. mirabilis produced single-strand breaks after UV-irradiation in contrast to HCR-mutants of E. coli. Therefore we suggest that HCR-mutants of P. mirabilis are not completely inhibited in the incision step. The single-strand breaks introduced in the DNA at the beginning of the repair process were not rejoined during further incubation. Experiments with toluenized cells led to the same results. The newly synthesized daughter DNA-strands of UV-irradiated HCR-mutants were of low molecular weight in comparison with those from unirradiated control cells during the repair period. This result is in agreement with the incapability of HCR-mutants to remove the pyrimidine dimers from the parental template strand. (author)

  6. A new incision for unilateral cleft lip repair developed using animated simulation of repair on computer

    Directory of Open Access Journals (Sweden)

    Sahay A

    2007-01-01

    Full Text Available Background: Unilateral cleft lip repair continues to leave behind some amount of dissatisfaction, as a scope for further improvement is always felt. Most surgeons do not like to deviate from the standard Millard′s/ triangular techniques, or their minor modifications, as no one likes to experiment on the face for fear of unfavourable outcomes. The computer can be utilized as a useful tool in the analysis and planning of surgery and new methods can be developed and attempted subsequently with greater confidence. Aim: We decided to see if an improved lip repair could be developed with the use of computers. Materials and Methods: Analysis of previous lip repairs was done to determine where an improvement was required. Movement of tissues, by simulating an ideal repair, using image warping software, on digital images of cleft lip was studied in animation sequences. A repair which could reproduce these movements was planned. A new incision emerged, which had combined the principles of Millard′s and Randall / Tennyson repairs, with additional features. The new method was performed on 30 cases. Conclusions: The results were encouraging as the shortcomings of these methods were minimized, and the advantages maximized.

  7. Single incision laparoscopic surgery (SILS) inguinal hernia repair - recent clinical experiences of this novel technique.

    Science.gov (United States)

    Yussra, Y; Sutton, P A; Kosai, N R; Razman, J; Mishra, R K; Harunarashid, H; Das, S

    2013-01-01

    Inguinal hernia remains the most commonly encountered surgical problem. Various methods of repair have been described, and the most suitable one debated. Single port access (SPA) surgery is a rapidly evolving field, and has the advantage of affording 'scarless' surgery. Single incision laparoscopic surgery (SILS) for inguinal hernia repair is seen to be feasible in both total extraperitoneal (TEP) and transabdominal pre-peritoneal (TAPP) approaches. Data and peri-operative information on both of these however are limited. We aimed to review the clinical experience, feasibility and short term complications related to laparoscopic inguinal hernia repair via single port access. A literature search was performed using Google Scholar, Springerlink Library, Highwire Press, Surgical Endoscopy Journal, World Journal of Surgery and Medscape. The following search terms were used: laparoscopic hernia repair, TAPP, TEP, single incision laparoscopic surgery (SILS). Fourteen articles in English language related to SILS inguinal hernia repair were identified. Nine articles were related to TEP repair and the remaining 5 to TAPP. A total of 340 patients were reported within these studies: 294 patients having a TEP repair and 46 a TAPP. Only two cases of recurrence were reported. Various ports have been utilized, including the SILS port, Tri-Port and a custom- made port using conventional laparoscopic instruments. The duration of surgery was 40-100 minutes and the average length of hospital stay was one day. Early outcomes of this novel technique show it to be feasible, safe and with potentially better cosmetic outcome.

  8. STUDY OF VARIOUS MODALITIES IN MANAGEMENT OF INCISION HERNIA REPAIR

    Directory of Open Access Journals (Sweden)

    Raghu Rachha

    2018-03-01

    Full Text Available BACKGROUND Incisional hernias are a major problem following abdominal surgery and their repairs are among the common surgeries done by a general surgeon.1 Besides the preoperative factors such as anaemia, BMI over 25 kg/m2 and smoking which are leading causes contributing to the development of Incisional hernia, laparotomy performed through the abdominal incision doubles the risk of IH.2 In addition, wound infection, increases the risk of IH formation by 1.9 times.3 If left unattended they may attain large size therefore cause discomfort and lead to the complications like Obstruction, Strangulation, Incarceration increasing the risk of morbidity and mortality.4 Treatment of IH involves further major surgery and the results may be poor, with the recurrence rates of up to 49% reported.5 A wide spectrum of surgical techniques have been developed and recommended ranging from sutured techniques to the various types of prosthetic mesh. MATERIALS AND METHODS 30 patients were studied who presented to emergency department with incisional hernias during August 2014 – September 2016 at Gandhi Medical College and Hospital. All patients underwent definitive treatment. RESULTS From our study it is observed that 1. The maximum cases of incisional hernias presenting to the emergency surgical department were found to be in 51-60 years age group. 2. There was female preponderance. 3. Obstruction is the most common presenting symptom found in 60% of cases followed by irreducibility (33.3% and strangulation (6.67%. 4. The onset of incisional hernias is more after 10 years following previous surgery. 5. Among 30 patients, bowel was viable in 18 patients (60% and mesh repair was done in 13 patients. Bowel was gangrenous in 12 patients (40% and anatomical repair was done in 17 patients. 6. Out of 30, women got infected in 11 patients (36.67% wound dehiscence noted in 5 patients (16.67%. 7. The recurrence rate was 6.67% with 6 months follow up. CONCLUSION 1. The mean

  9. A Simple Method for Closure of Urethrocutaneous Fistula after Tubularized Incised Plate Repair: Preliminary Results.

    Science.gov (United States)

    Shirazi, Mehdi; Ariafar, Ali; Babaei, Amir Hossein; Ashrafzadeh, Abdosamad; Adib, Ali

    2016-11-01

    Urethrocutaneous fistula (UCF) is the most prevalent complication after hypospadias repair surgery. Many methods have been developed for UCF correction, and the best technique for UCF repair is determined based on the size, location, and number of fistulas, as well as the status of the surrounding skin. In this study, we introduced and evaluated a simple method for UCF correction after tubularized incised plate (TIP) repair. This clinical study was conducted on children with UCFs ≤ 4 mm that developed after TIP surgery for hypospadias repair. The skin was incised around the fistula and the tract was released from the surrounding tissues and the dartos fascia, then ligated with 5 - 0 polydioxanone (PDS) sutures. The dartos fascia, as the second layer, was covered on the fistula tract with PDS thread (gauge 5 - 0) by the continuous suture method. The skin was closed with 6 - 0 Vicryl sutures. After six months of follow-up, surgical outcomes were evaluated based on fistula relapse and other complications. After six months, relapse occurred in only one patient, a six-year-old boy with a single 4-mm distal opening, who had undergone no previous fistula repairs. Therefore, in 97.5% of the cases, relapse was non-existent. Other complications, such as urethral stenosis, intraurethral obstruction, and epidermal inclusion cysts, were not seen in the other patients during the six-month follow-up period. This repair method, which is simple, rapid, and easily learned, is highly applicable, with a high success rate for the closure of UCFs measuring up to 4 mm in any location.

  10. Comparison between Tubularised Incised Plate Urethroplasty and Onlay Island Flap Repair in Mid and Proximal Penile Hypospadias

    Energy Technology Data Exchange (ETDEWEB)

    Javid, L.; Pansota, M. S.; Ahmad, I.; Tariq, M.; Tabassum, S. A. [Bahawal Victoria Hospital Quaid-e-Azam Medical College, Bahawalpur (Pakistan). Dept. of Urology

    2014-04-15

    Objectives: To evaluate the surgical outcome of tubularised incised plate urethroplasty and onlay island flap repair for mid and proximal penile hypospadias. Methods: The prospective study was conducted at the Bahawal Victoria Hospital, Bahawalpur from June 2011 to May 2013. A total of 60 patients with mid and proximal penile hypospadias in the age range of 02 to 06 years were included. Patients with hypospadias other than mid and proximal penile, with chordee and history of previous hypospadias repair were excluded. Patients were divided into two equal groups. Urethroplasty was done for group I and flap repair for group II. The follow-up period was 12-24 months. SPSS 16 was used for statistical analysis. Results: The mean duration of surgery was 62+-8.72 minutes for group I and 90+-11.25 minutes for group II (p<0.0001). In group I, only 03 (10.0%) patients had complications, while in group II, 09 (30.0%) patients developed complications (p=0.02). Cosmetic results were also excellent in group I compared to group II. Conclusion: Tubularised incised plate urethroplasty was better and superior than onlay island flap repair in terms of less operative time, complication rate and satisfactory cosmetic results for mid and proximal penile hypospadias. (author)

  11. Comparison between tubularised incised plate urethroplasty and onlay island flap repair in mid and proximal penile hypospadias.

    Science.gov (United States)

    Javid, Latif; Pansota, Mudassar Saeed; Ahmad, Iftikhar; Tariq, Muhammad; Tabassum, Shafqat Ali

    2014-04-01

    To evaluate the surgical outcome of tubularised incised plate urethroplasty and onlay island flap repair for mid and proximal penile hypospadias. The prospective study was conducted at the Bahawal Victoria Hospital, Bahawalpur from June 2011 to May 2013. A total of 60 patients with mid and proximal penile hypospadias in the age range of 02 to 06 years were included. Patients with hypospadias other than mid and proximal penile, with chordee and history of previous hypospadias repair were excluded. Patients were divided into two equal groups. Urethroplasty was done for group I and flap repair for group II. The follow-up period was 12-24 months. SPSS 16 was used for statistical analysis. The mean duration of surgery was 62 +/- 8.72 minutes for group I and 90 +/- 11.25 minutes for group II (p < 0.0001). In group I, only 03 (10.0%) patients had complications, while in group II, 09 (30.0%) patients developed complications (p = 0.02). Cosmetic results were also excellent in group I compared to group II. Tubularised incised plate urethroplasty was better and superior than onlay island flap repair in terms of less operative time, complication rate and satisfactory cosmetic results for mid and proximal penile hypospadias.

  12. Comparison between Tubularised Incised Plate Urethroplasty and Onlay Island Flap Repair in Mid and Proximal Penile Hypospadias

    International Nuclear Information System (INIS)

    Javid, L.; Pansota, M.S.; Ahmad, I.; Tariq, M.; Tabassum, S.A.

    2014-01-01

    Objectives: To evaluate the surgical outcome of tubularised incised plate urethroplasty and onlay island flap repair for mid and proximal penile hypospadias. Methods: The prospective study was conducted at the Bahawal Victoria Hospital, Bahawalpur from June 2011 to May 2013. A total of 60 patients with mid and proximal penile hypospadias in the age range of 02 to 06 years were included. Patients with hypospadias other than mid and proximal penile, with chordee and history of previous hypospadias repair were excluded. Patients were divided into two equal groups. Urethroplasty was done for group I and flap repair for group II. The follow-up period was 12-24 months. SPSS 16 was used for statistical analysis. Results: The mean duration of surgery was 62+-8.72 minutes for group I and 90+-11.25 minutes for group II (p<0.0001). In group I, only 03 (10.0%) patients had complications, while in group II, 09 (30.0%) patients developed complications (p=0.02). Cosmetic results were also excellent in group I compared to group II. Conclusion: Tubularised incised plate urethroplasty was better and superior than onlay island flap repair in terms of less operative time, complication rate and satisfactory cosmetic results for mid and proximal penile hypospadias. (author)

  13. Effects of post-treatment incubation on recombinogenesis in incision-proficient and incision-deficient strains of saccharomyces cerevisiae, 2

    International Nuclear Information System (INIS)

    Saeki, Tetsuya; Machida, Isamu

    1991-01-01

    After the photoaddition of mono- and bifunctional furocoumarins to G1 phase cells, most gene conversion and crossing-over occurred without post-irradiation incubation of these cells in incision-proficient strains. In contrast, incision-deficient cells showed marked induction of both recombinational events only after treated cells had been incubated for several hours before selection. These results indicate that when furocoumarins are photoadded to G1 cells, initiation of recombinational events occurs during the same G1 phase in the incision-proficient cells; whereas, it occurs only after post-irradiation DNA replication in incision-deficient cells. The action of the PSO2 gene product specific for the repair of DNA crosslinks in recombination induction is discussed and compared to the actions of the excision repair genes RAD1 and RAD2. (author)

  14. Long-Term Incisal Relationships After Palatoplasty in Patients With Isolated Cleft Palate.

    Science.gov (United States)

    Odom, Elizabeth B; Woo, Albert S; Mendonca, Derick A; Huebener, Donald V; Nissen, Richard J; Skolnick, Gary B; Patel, Kamlesh B

    2016-06-01

    Various palatoplasty techniques have limited incisions in the hard palate due to concerns that these incisions may limit maxillary growth. There is little convincing long-term evidence to support this. Our purpose is to determine incisal relationships, an indicator for future orthognathic procedure, in patients after repair of an isolated cleft of the secondary palate. Our craniofacial database was used to identify patients aged 10 years or greater with an isolated cleft of the secondary palate who underwent palatoplasty between 1985 and 2002. Data collected included age at palatoplasty and follow-up, cleft type, associated syndrome, Robin sequence, surgeon, repair technique, number of operations, and occlusion. Incisal relationship was determined through clinical observation by a pediatric dentist and orthodontist. Seventy eligible patients operated on by 9 surgeons were identified. Class III incisal relationship was seen in 5 patients (7.1%). Palatoplasty techniques over the hard palate (63 of 70 patients) included 2-flap palatoplasty, VY-pushback, and Von Langenbeck repair. There was an association between class III incisal relationship and syndromic diagnosis (P <0.001). Other study variables were not associated with class III incisal relationships. In patients with an isolated cleft of the secondary palate, there was no association between class III incisal relationship and surgeon, age at repair, cleft type, palatoplasty technique, or number of operations. Increased likelihood of class III incisal relationship was associated primarily with syndromic diagnosis.

  15. Evidence that novobiocin and nalidixic acid do not inhibit excision repair in u.v.-irradiated human skin fibroblasts at a pre-incision

    International Nuclear Information System (INIS)

    Keyse, S.M.; Tyrrell, R.M.

    1985-01-01

    The effects of novobiocin and nalidixic acid on the specific toxicity of aphidicolin towards u.v. irradiated arrested human skin fibroblasts have been determined. Contrary to the result expected if either drug were causing inhibition of excision repair at a pre-incision step the sector of toxicity due to a combined treatment of 300 μg ml -1 nalidixic acid and 1.0 μg ml -1 aphidicolin is unchanged when compared with that due to treatment with 1.0 μg ml -1 aphidicolin alone, while that for 150 μg ml -1 novobiocin + 1.0 μg ml -1 aphidicolin was slightly increased. In parallel measurements of the inhibition of u.v.-induced DNA repair synthesis in arrested fibroblasts by these drugs, 150 μg ml -1 novobiocin inhibited repair synthesis by approx.60% over the fluence range employed. Nalidixic acid (300 μg ml -1 ) caused no detectable inhibition of repair synthesis. It was concluded that the mode of action of novobiocin in the inhibition of DNA excision repair is not via the inhibition of a pre-incision step and the data do not support the hypothesis that a type II topoisomerase mediated change in DNA supercoiling is an essential early step in excision repair of u.v.-induced damage. (author)

  16. Evidence that novobiocin and nalidixic acid do not inhibit excision repair in u.v.-irradiated human skin fibroblasts at a pre-incision step

    International Nuclear Information System (INIS)

    Keyse, S.M.; Tyrrell, R.M.

    1985-01-01

    The effects of novobiocin and nalidixic acid on the specific toxicity of aphidicolin towards u.v. irradiated arrested (nondividing) human skin fibroblasts have been determined. Contrary to the result expected if either drug were causing inhibition of excision repair at a pre-incision step the sector of toxicity due to a combined treatment of 300 micrograms ml -1 nalidixic acid and 1.0 micrograms ml -1 aphidicolin is unchanged when compared with that due to treatment with 1.0 micrograms ml -1 aphidicolin alone, while that for 150 micrograms ml -1 novobiocin + 1.0 micrograms ml -1 aphidicolin was slightly increased. In parallel measurements of the inhibition of u.v.-induced DNA repair synthesis in arrested fibroblasts by these drugs, 150 micrograms ml -1 novobiocin inhibited repair synthesis by approximately 60% over the fluence range employed. Nalidixic acid at a concentration of 300 micrograms ml -1 caused no detectable inhibition of repair synthesis. The authors conclude that the mode of action of novobiocin in the inhibition of DNA excision repair is not via the inhibition of a pre-incision step and the data do not support the hypothesis that a type II topoisomerase mediated change in DNA supercoiling is an essential early step in excision repair of u.v.-induced damage

  17. Higher Incision at Upper Part of Lower Segment Caesarean Section

    Directory of Open Access Journals (Sweden)

    Yong Shao

    2014-06-01

    Conclusions: An incision at the upper part of the lower segment reduces blood loss, enhances uterine retraction, predisposes to fewer complications, is easier to repair, precludes bladder adhesion to the suture line and reduces operation time. Keywords: caesarean section; higher incision technique; traditional uterine incision technique.

  18. Repair of a submucous cleft palate by W-pushback and levator repositioning without incision to the nasal mucosa.

    Science.gov (United States)

    Hwang, Kun

    2012-03-01

    The author created an innovative method of W-pushback and levator repositioning without having to make an incision to the nasal mucosa for submucous cleft palate repair.The W-shaped mucoperiosteal flap is outlined where the 2 peaks of W are the alveolar processes of both canine teeth and the midpoint of W is the anterior limit of the cleft notch of the hard palate. A short incision, medial to and behind the maxillary tuberosity and curved forward onto the palate and extended forward just medial to the alveolar process, is joined by a second incision from the apex of the cleft to the region of the canine tooth. The W-shaped mucoperiosteal flap is raised until the midline notch of the hard palate is exposed. The nasal mucosa and abnormally inserted levator veli palatini muscle to the posterior border of the hard palate bone are detached. By leaving the nasal mucosa intact, the detached levator veli palatini muscle is approximated at the midline and so the zona pellucida is obliterated. The cleft uvulas are cut in half and closed. The approximated W-flap is joined to the small anterior flap by 1 or more sutures (the W-pushback).Three patients were operated on with this technique without serious complications.The author believes that this method can make the levator sling and increase the length of the soft palate without making an incision to the nasal mucosa.

  19. Human FAN1 promotes strand incision in 5'-flapped DNA complexed with RPA.

    Science.gov (United States)

    Takahashi, Daisuke; Sato, Koichi; Hirayama, Emiko; Takata, Minoru; Kurumizaka, Hitoshi

    2015-09-01

    Fanconi anaemia (FA) is a human infantile recessive disorder. Seventeen FA causal proteins cooperatively function in the DNA interstrand crosslink (ICL) repair pathway. Dual DNA strand incisions around the crosslink are critical steps in ICL repair. FA-associated nuclease 1 (FAN1) is a DNA structure-specific endonuclease that is considered to be involved in DNA incision at the stalled replication fork. Replication protein A (RPA) rapidly assembles on the single-stranded DNA region of the stalled fork. However, the effect of RPA on the FAN1-mediated DNA incision has not been determined. In this study, we purified human FAN1, as a bacterially expressed recombinant protein. FAN1 exhibited robust endonuclease activity with 5'-flapped DNA, which is formed at the stalled replication fork. We found that FAN1 efficiently promoted DNA incision at the proper site of RPA-coated 5'-flapped DNA. Therefore, FAN1 possesses the ability to promote the ICL repair of 5'-flapped DNA covered by RPA. © The Authors 2015. Published by Oxford University Press on behalf of the Japanese Biochemical Society. All rights reserved.

  20. The DNA Repair Repertoire of Mycobacterium smegmatis FenA Includes the Incision of DNA 5' Flaps and the Removal of 5' Adenylylated Products of Aborted Nick Ligation.

    Science.gov (United States)

    Uson, Maria Loressa; Ghosh, Shreya; Shuman, Stewart

    2017-09-01

    We characterize Mycobacterium smegmatis FenA as a manganese-dependent 5'-flap endonuclease homologous to the 5'-exonuclease of DNA polymerase I. FenA incises a nicked 5' flap between the first and second nucleotides of the duplex segment to yield a 1-nucleotide gapped DNA, which is then further resected in dinucleotide steps. Initial FenA cleavage at a Y-flap or nick occurs between the first and second nucleotides of the duplex. However, when the template 3' single strand is eliminated to create a 5'-tailed duplex, FenA incision shifts to between the second and third nucleotides. A double-flap substrate with a mobile junction (mimicking limited strand displacement synthesis during gap repair) is preferentially incised as the 1-nucleotide 3'-flap isomer, with the scissile phosphodiester shifted by one nucleotide versus a static double flap. FenA efficiently removes the 5' App(dN) terminus of an aborted nick ligation reaction intermediate, thereby highlighting FenA as an agent of repair of such lesions, which are formed under a variety of circumstances by bacterial NAD + -dependent DNA ligases and especially by mycobacterial DNA ligases D and C. IMPORTANCE Structure-specific DNA endonucleases are implicated in bacterial DNA replication, repair, and recombination, yet there is scant knowledge of the roster and catalytic repertoire of such nucleases in Mycobacteria This study identifies M. smegmatis FenA as a stand-alone endonuclease homologous to the 5'-exonuclease domain of mycobacterial DNA polymerase 1. FenA incises 5' flaps, 5' nicks, and 5' App(dN) intermediates of aborted nick ligation. The isolated N-terminal domain of M. smegmatis Pol1 is also shown to be a flap endonuclease. Copyright © 2017 American Society for Microbiology.

  1. Repair of single-strand breaks induced in the DNA of Proteus mirabilis by excision repair after UV-irradiation

    International Nuclear Information System (INIS)

    Stoerl, K.; Mund, C.

    1977-01-01

    Single-strand breaks have been produced in the DNA of P. mirabilis after UV-irradiation in dependence on the incident UV-doses. It has been found that there exists a discrepancy between the single-strand breaks estimated from sedimentation in alkaline sucrose gradients and the expected single-strand breaks approximated from measurements of dimer excision. The low number in incision breaks observed by sedimentation experiments is an indication that the cells are able to repair the excision-induced breaks as fast as they are formed. Toluenized cells have been used for investigation of the incision step independently of subsequent repair processes. In presence of NMN the appearance of more single-strand breaks in the DNA has been observed. Furthermore, the number of incision breaks in toluenized cells increased in presence of exogenous ATP. The completion of the excision repair process has been investigated by observing the rejoining of incision breaks. After irradiation with UV-doses higher than approximately 240 erg/mm 2 the number of single-strand breaks remaining unrepaired in the DNA increased. Studies of the influence of nutrition conditions on the repair process have shown approximately the same capacity for repair of single-strand breaks in growth medium as well as in buffer. Progress in the excision repair was also followed by investigation of the DNA synthesized at the template-DNA containing the pyrimidine dimers. In comparison with E. coli, P. mirabilis showed a somewhat lower efficiency for the repair of single-strand breaks during the excision repair. (author)

  2. A feasibility of single-incision laparoscopic percutaneous extraperitoneal closure for treatment of incarcerated inguinal hernia in children: our preliminary outcome and review of the literature.

    Science.gov (United States)

    Murase, Naruhiko; Uchida, Hiroo; Seki, Takashi; Hiramatsu, Kiyoshi

    2016-02-01

    The purpose of this study is to examine the feasibility of single-incision laparoscopic percutaneous extraperitoneal closure (LPEC) for incarcerated inguinal hernia (IIH) repair. 6 single-incision LPEC procedures were performed for IIH repair and 60 procedures were performed for reducible inguinal hernia (RIH) in the same period of time in one hospital. The laparoscope and one pair of grasping forceps were placed through the same umbilical incision. In IIH repair, the herniated organ was gently pulled using the grasping forceps with external manual pressure. If it was difficult to reduce the herniated organ with one pair of forceps, another pair of forceps were inserted through a multi-channel port without extending the umbilical incidion. Using the LPEC needle, the hernia orifice was closed extraperitoneally. We performed a retrospective analysis to compare the outcomes of single-incision LPEC for IIH repair or reducible inguinal hernia. All procedures were completed by single-incision without open conversion. A multi-channel port with another pair of forceps was needed in three cases. The operation time and the length of stay were significantly longer with IIH repair than with RIH repair. There were no major complications and there was no evidence of early recurrence in any patient. In conclusion, single-incision LPEC with a multi-channel port is feasible and safe for IIH repair.

  3. DNA-repair measurements by use of the modified comet assay

    DEFF Research Database (Denmark)

    Godschalk, Roger W L; Ersson, Clara; Riso, Patrizia

    2013-01-01

    The measurement of DNA-repair activity by extracts from cells or tissues by means of the single-cell gel electrophoresis (comet) assay has a high potential to become widely used in biomonitoring studies. We assessed the inter-laboratory variation in reported values of DNA-repair activity...... on substrate cells that had been incubated with Ro19-8022 plus light to generate oxidatively damaged DNA. Eight laboratories assessed the DNA-repair activity of three cell lines (i.e. one epithelial and two fibroblast cell lines), starting with cell pellets or with cell extracts provided by the coordinating...... laboratory. There was a large inter-laboratory variation, as evidenced by the range in the mean level of repair incisions between the laboratory with the lowest (0.002incisions/10(6)bp) and highest (0.988incisions/10(6)bp) incision activity. Nevertheless, six out of eight laboratories reported the same cell...

  4. Open fenestration of the distal landing zone via a subxyphoid incision for subsequent endovascular repair of a dissecting thoracic aneurysm.

    Science.gov (United States)

    Konings, Renske; de Bruin, Jorg L; Wisselink, Willem

    2013-02-01

    To describe a novel hybrid technique to address two challenges in endovascular repair of chronic dissecting thoracic aortic aneurysm (dTAA): obtaining an adequate seal of the stent-graft in a half-moon-shaped fibrotic aortic lumen and preserving flow into the distal true and false lumens. The technique is demonstrated in a 52-year-old man who presented with progressive asymptomatic dilatation of the thoracic aorta 9 years after undergoing a Bentall procedure for a Stanford type A dissection followed by arch replacement and elephant trunk construction. Imaging at this admission showed a 6.8-cm dissecting aneurysm extending distally to ∼4 cm above the celiac trunk; the dissection included both common iliac arteries. The patient refused a thoracotomy, so a hybrid procedure was devised to resect the intimal flap via a median subxyphoid incision and transperitoneal approach through the lesser sac. Two overlapping Zenith TX-2 stent-grafts were deployed into the elephant trunk, terminating just above the surgically created "flow divider" at the level of the celiac trunk. Imaging showed adequate sealing at both ends of the stent-graft and a type II endoleak that persisted into follow-up, but the aneurysm diameter decreased to 6.4 cm, and there was unobstructed flow into the visceral, renal, and iliac arteries. In this case of chronic dTAA, open surgical removal of a segment of the dissection flap via a subxyphoid incision provided a distal landing zone for subsequent endoluminal repair, with exclusion of the aneurysm and preservation of antegrade flow in both true and false lumens.

  5. Cleft Palate Repair Using a Double Opposing Z-Plasty.

    Science.gov (United States)

    Moores, Craig; Shah, Ajul; Steinbacher, Derek M

    2016-07-01

    Cleft palate is a common congenital defect with several described surgical repairs. The most successful treatment modality remains a controversy. The goals of repair focus on achievement of normal speech and optimizing velopharyngeal function while minimizing both fistula formation and facial growth restriction. In this video, the authors demonstrate use of the double opposing Z-plasty technique in the repair of a Veau II type cleft palate. The video demonstrates the marking, incisions, dissection, and repair of the cleft. It also examines the use of von Langenbeck-type relaxing incisions and demonstrates a specific approach to the repair of this particular cleft. The authors believe that the Furlow double opposing Z-plasty with the von Langenbeck relaxing incision can provide the best postoperative outcome by combining the benefits of each individual operation. The Z-plasty technique works to correct the aberrant muscle of the soft palate while increasing the length of the palate. The authors believe that this results in better velopharyngeal function.

  6. Tubularized incised plate technique for recurrent hypospadias: a ...

    African Journals Online (AJOL)

    management of recurrent hypospadias. Summary background ... The potential advantages of tubularized incised plate .... after a mean duration of 4.9 ± 3.1 years from the previous repair (Table 2). .... erection and the risk of infection, especially in patients older than 15 .... However, previous surgery often limits the availability ...

  7. The inverted Batman incision: a new incision in transcolumellar incision for open rhinoplasty.

    Science.gov (United States)

    Nakanishi, Yuji; Nagasao, Tomohisa; Shimizu, Yusuke; Miyamoto, Junpei; Fukuta, Keizo; Kishi, Kazuo

    2013-12-01

    Columellar and nostril shapes often present irregularity after transcolumellar incision for open rhinoplasty, because of the contracture of the incised wound. The present study introduces a new technique to prevent this complication, and verifies its efficacy in improving cosmetic appearance. In our new method, a zig-zag incision with three small triangular flaps is made on the columella and in the pericolumellar regions of the bilateral nostril rims. Since the shape of the incision resembles the contour of an inverted "batman", we term our new method the "Inverted Batman" incision. To verify the effectiveness of the Inverted Batman incision, aesthetic evaluation was conducted for 21 patients operated on using the conventional transcolumellar incision (Conventional Group) and 19 patients operated on using the Inverted Batman incision (Inverted Batman Group). The evaluation was performed by three plastic surgeons, using a four-grade scale to assess three separate items: symmetry of bilateral soft triangles, symmetry of bilateral margins of the columella, and evenness of the columellar surface. The scores of the two groups for these three items were compared using a non-parametric test (Mann-Whitney U-test). With all three items, the Inverted Batman group patients present higher scores than Conventional Group patients. The Inverted Batman incision is effective in preserving the correct anatomical structure of the columella, soft triangle, and nostril rims. Hence, we recommend the Inverted Batman incision as a useful technique for open rhinoplasty.

  8. Repair of UV-irradiated plasmid DNA in excision repair deficient mutants of Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Ikai, K.; Tano, K.; Ohnishi, T.; Nozu, K.

    1985-01-01

    The repair of UV-irradiated DNA of plasmid YEp13 was studied in the incision defective strains by measurement of cell transformation frequency. In Saccharomyces cerevisiae, rad1,2,3 and 4 mutants could repair UV-damaged plasmid DNA. In Escherichia coli, uvrA mutant was unable to repair UV-damaged plasmid DNA; however, pretreatment of the plasmid with Micrococcus luteus endonuclease increased repair. It was concluded that all the mutations of yeast were probably limited only to the nuclear DNA. (author)

  9. Temperature-controlled laser-soldering system and its clinical application for bonding skin incisions

    Science.gov (United States)

    Simhon, David; Gabay, Ilan; Shpolyansky, Gregory; Vasilyev, Tamar; Nur, Israel; Meidler, Roberto; Hatoum, Ossama Abu; Katzir, Abraham; Hashmonai, Moshe; Kopelman, Doron

    2015-12-01

    Laser tissue soldering is a method of repairing incisions. It involves the application of a biological solder to the approximated edges of the incision and heating it with a laser beam. A pilot clinical study was carried out on 10 patients who underwent laparoscopic cholecystectomy. Of the four abdominal incisions in each patient, two were sutured and two were laser soldered. Cicatrization, esthetical appearance, degree of pain, and pruritus in the incisions were examined on postoperative days 1, 7, and 30. The soldered wounds were watertight and healed well, with no discharge from these wounds or infection. The total closure time was equal in both methods, but the net soldering time was much shorter than suturing. There was no difference between the two types of wound closure with respect to the pain and pruritus on a follow-up of one month. Esthetically, the soldered incisions were estimated as good as the sutured ones. The present study confirmed that temperature-controlled laser soldering of human skin incisions is clinically feasible, and the results obtained were at least equivalent to those of standard suturing.

  10. The fourth incision: a cosmetic autopsy incision technique.

    Science.gov (United States)

    Patowary, Amarjyoti

    2010-03-01

    Autopsy procedure includes thorough external examination as well as internal examination including opening of all the body cavities for proper visualization of all the visceral organs. As such, there remains incision marks with stitches which harts the sentiment of the already traumatized relatives of the deceased. Moreover, it looks odd especially in cases of otherwise healthy dead bodies. So, autopsy incisions should be such that, we can get maximum possible visualization of the body cavities, particularly the thorax and abdomen, and at the same time the incision as well as the stitch marks are also hidden. This article is aimed to describe few modifications in the autopsy incisions for opening the thorax and abdomen and also proper visualization of the neck structures during autopsy where the incisions and the stitches are kept hidden.

  11. In vivo near infrared (NIRS) sensor attachment using fibrin bioadhesive

    Science.gov (United States)

    Macnab, Andrew; Pagano, Roberto; Kwon, Brian; Dumont, Guy; Shadgan, Babak

    2018-02-01

    Background: `Tisseel' (Baxter Healthcare, Deerfield, IL) is a fibrin-based sealant that is commonly used during spine surgery to augment dural repairs. We wish to intra-operatively secure a near infrared spectroscopy (NIRS) sensor to the dura in order to monitor the tissue hemodynamics of the underlying spinal cord. To determine if `Tisseel' sealant adversely attenuates NIR photon transmission. Methods: We investigated `Tisseel' in both an in vitro and in vivo paradigm. For in vitro testing, we used a 1 mm pathlength cuvette containing either air or `Tisseel' interposed between a NIR light source (760 and 850 nm) and a photodiode detector and compared transmittance. For in vivo testing, a continuous wave (760 and 850 nm) spatiallyresolved NIRS device was placed over the triceps muscle using either conventional skin apposition (overlying adhesive bandage) or bioadhesion with `Tisseel'. Raw optical data and tissue saturation index (TSI%) collected at rest were compared. Results: In-vitro NIR light absorption by `Tisseel' was very high, with transmittance reduced by 95% compared to air. In-vivo muscle TSI% values were 80% with conventional attachment and 20% using fibrin glue. Conclusion: The optical properties of `Tisseel' significantly attenuate NIR light during in-vitro transmittance and critically compromise photon transmission in-vivo.

  12. Tubularized proximally-incised plate in distal/midshaft hypospadias repair

    Directory of Open Access Journals (Sweden)

    Antonio Marte

    2017-06-01

    Full Text Available The aim of this study was to verify the validity, feasibility, and the functional results, by uroflowmetry, of Tubularized proximallyincised plate technique in selected case of distal/midshaft hypospadias. Out of 120 patients scheduled to undergo TIP (or Snodgrass procedure, 23 were selected between January 2013 and January 2016 (19.1%. This case series comprised 16 patients with distal and 7 with midshaft hypospadias. Mean age at surgery was 2.9 years. The inclusion criteria were a deep and wide glandular groove and a proximal narrow urethral plate. The procedure was carried out as described by Snodgrass but the incision of the urethral plate, including the mucosal and submucosal tissue, was made only proximally, between the original meatus and the glandular groove in no case extending to the entire length of the plate. Postoperatively a foley catheter was left in place from 4 to 7 days. Uroflowmetry was performed when the patients age ranged from 2.5 to 5.7 years (mean age 3.11 years and mean follow-up 1.8 years, body surface 2. No patient presented fistulas nor perioperative complications. At uroflowmetry, eighteen patients presented values above the 25th percentile and 5 showed a borderline flow. All patients in this group remained stable without urinary symptoms. In selected cases, the tubularized proximally-incised plate yields satisfactory cosmetic and functional results for the treatment of midshaft proximal hypospadias. A long-term follow-up study is needed for further evaluation. Patient selection is crucial for the success of this technique.

  13. Transconjunctival incision for total maxillectomy--an alternative for subciliary incision.

    Science.gov (United States)

    Goyal, Amit; Tyagi, Isha; Jain, Shilpa; Syal, Rajan; Singh, Alok Pratap; Kapila, Rajeev

    2011-09-01

    A subciliary incision may be associated with various complications of the lower eyelid when it is used during a total maxillectomy. The use of the transconjunctival incision instead is an alternative in suitable patients. The records of 17 patients were reviewed in whom a transconjunctival incision was used during total maxillectomy. These included 13 in whom the Weber-Ferguson incision was used, and 4 who had a sublabial incision. There was mild conjunctival oedema in all the cases during the immediate postoperative period but it did not last for more than two days. Four patients had mild to moderate oedema of the lid that resolved within two days. One had mild ectropion with transient epiphora, which was caused by early removal of the medial canthal sutures. We found the approach to be cosmetically acceptable as it avoids a scar in the subciliary region. The transconjunctival incision can be used in place of the subciliary incision for lateral exposure during total maxillectomy. There are few complications associated with the lower lid, and it has good cosmetic results; if it is combined with a sublabial incision in suitable patients, the maxillectomy is virtually scar-free. Copyright © 2010 British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. DNA repair in ultraviolet-irradiated spores of Bacillus subtilis

    International Nuclear Information System (INIS)

    Wang, T.C.V.

    1976-01-01

    It has been shown previously by others that at least two independent repair mechanisms are present in Bacillus subtilis for removing ''spore photoproduct'' from DNA of ultraviolet (254 nm)-irradiated spores after germination. One of these, designated as ''spore repair,'' is shown in this study to restore ''spore photoproduct'' to two thymine residues, leaving the DNA backbone intact at the end of the process in vivo. The circumstances under which this repair can occur and some characteristics of its energy requirements have been clarified. The second repair process is identified as excision repair, which can excise both ''spore photoproduct'' from DNA of irradiated spores and cyclobutane-type pyrimidine dimers from DNA of irradiated vegetative cells. In this study it is shown that the gene hcr 1 affects an enzyme activity for the incision step initiating this repair, while the gene hcr 42 affects a step subsequent to incision in the mechanism. In addition a third, independent repair system, termed ''germinative excision repair,'' is discovered and shown to be specific for excising only cyclobutane-type pyrimidine dimers but not ''spore photoproduct.'' This repair system is responsible for the observed high ultraviolet-resistance and temporary capacity for host cell reactivation on recently germinated spores of Bacillus subtilis HCR - strains

  15. Excision of thymine dimers from specifically incised DNA by extracts of xeroderma pigmentosum cells

    Energy Technology Data Exchange (ETDEWEB)

    Cook, K; Friedberg, E C; Slor, H; Cleaver, J E

    1975-07-17

    DNA repair defects as exhibited in fibroblasts from patients with xeroderma pigmentosa were studied. Five complementation groups for excision-repair defects were examined to test the hypothesis that a defective endonuclease or exonuclease may be the cause. No evidence was found to indicate that the enzyme activity functions in dimer excision. Since ultraviolet irradiated E. coli DNA incised with an endonuclease purified from phage-infected cells were used, it is possible that other factors may be involved in human UV endonuclease action. (JWP)

  16. Conserved structural chemistry for incision activity in structurally non-homologous apurinic/apyrimidinic endonuclease APE1 and endonuclease IV DNA repair enzymes.

    Energy Technology Data Exchange (ETDEWEB)

    Tsutakawa, Susan E.; Shin, David S.; Mol, Clifford D.; Izum, Tadahide; Arvai, Andrew S.; Mantha, Anil K.; Szczesny, Bartosz; Ivanov, Ivaylo N.; Hosfield, David J.; Maiti, Buddhadev; Pique, Mike E.; Frankel, Kenneth A.; Hitomi, Kenichi; Cunningham, Richard P.; Mitra, Sankar; Tainer, John A.

    2013-03-22

    Non-coding apurinic/apyrimidinic (AP) sites in DNA form spontaneously and as DNA base excision repair intermediates are the most common toxic and mutagenic in vivo DNA lesion. For repair, AP sites must be processed by 5' AP endonucleases in initial stages of base repair. Human APE1 and bacterial Nfo represent the two conserved 5' AP endonuclease families in the biosphere; they both recognize AP sites and incise the phosphodiester backbone 5' to the lesion, yet they lack similar structures and metal ion requirements. Here, we determined and analyzed crystal structures of a 2.4 ? resolution APE1-DNA product complex with Mg(2+) and a 0.92 Nfo with three metal ions. Structural and biochemical comparisons of these two evolutionarily distinct enzymes characterize key APE1 catalytic residues that are potentially functionally similar to Nfo active site components, as further tested and supported by computational analyses. We observe a magnesium-water cluster in the APE1 active site, with only Glu-96 forming the direct protein coordination to the Mg(2+). Despite differences in structure and metal requirements of APE1 and Nfo, comparison of their active site structures surprisingly reveals strong geometric conservation of the catalytic reaction, with APE1 catalytic side chains positioned analogously to Nfo metal positions, suggesting surprising functional equivalence between Nfo metal ions and APE1 residues. The finding that APE1 residues are positioned to substitute for Nfo metal ions is supported by the impact of mutations on activity. Collectively, the results illuminate the activities of residues, metal ions, and active site features for abasic site endonucleases.

  17. Ultraviolet and chemical induced DNA repair in human cells assayed by bromodeoxyuridine photolysis or cytosine arabinoside arrest

    International Nuclear Information System (INIS)

    Regan, J.D.; Dunn, W.C.

    1979-01-01

    The bromodeoxyuridine photolysis assay of DNA damage in human cells permits an estimate of both the number of repaired regions in the DNA and the size of the average repaired region - the patch size. The antineoplastic agent arabinofuranosyl cytosine (ara-C) can also be employed to assay the magnitude of repair since this agent appears to block rejoining of single-strand incisions made in the DNA during the initial step of repair. Thus, the number of incisions can be accumulated. The ara-C effect is dependent on the presence of hydroxyurea. Both assays can be employed for the study of physical or chemical DNA damages. Results comparing these assays are presented

  18. Immediate and repair induced DNA double strand breaks in mammalian cells

    International Nuclear Information System (INIS)

    Bryant, P.E.

    1986-01-01

    It seems logical to postulate that double strand breaks (dsb) arising both at the time of irradiation and via repair processes are potentially equally damaging for a cell in terms of the potential to induce chromosomal aberrations. However, in some cell systems the repair of double es or es-ssb sites may run concurrently with the incision so that these lesions do not remain open for long: hence the lack of accumulation of dsb during repair. The rate of incision will thus determine both the accumulation and the probability of exchanges leading to chromosomal aberrations between these and other frank dsb. Rapid incision leading to a large additional pool of dsb appears to be the case in Chinese hamster V79 cells. Some evidence also exists for the conversion of base damage, via dsb, into deletion type chromatid aberrations which accumulate in irradiated G2 human cells treated with ara C. A small fraction of dsb, probably arising both at the time of irradiation as well as enzymatically during repair of base or sugar damage, appears to be either left unrepaired, yielding deletion type chromosomal aberrations, or is misrepaired, yielding exchange aberrations. The induction of these aberrations appears to be of central importance in the biological effects of ionizing radiation such as mutations, oncogenic transformation, and cell death. 52 refs., 5 figs

  19. Comparison of surgically induced astigmatism in various incisions in manual small incision cataract surgery.

    Science.gov (United States)

    Jauhari, Nidhi; Chopra, Deepak; Chaurasia, Rajan Kumar; Agarwal, Ashutosh

    2014-01-01

    To determine the surgically induced astigmatism (SIA) in Straight, Frown and Inverted V shape (Chevron) incisions in manual small incision cataract surgery (SICS). A prospective cross sectional study was done on a total of 75 patients aged 40y and above with senile cataract. The patients were randomly divided into three groups (25 each). Each group received a particular type of incision (Straight, Frown or Inverted V shape incisions). Manual SICS with intraocular lens (IOL) implantation was performed. The patients were compared 4wk post operatively for uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA) and SIA. All calculations were performed using the SIA calculator version 2.1, a free software program. The study was analyzed using SPSS version 15.0 statistical analysis software. The study found that 89.5% of patients in Straight incision group, 94.2% in Frown incision group and 95.7% in Inverted V group attained BCVA post-operatively in the range of 6/6 to 6/18. Mean SIA was minimum (-0.88±0.61D×90 degrees) with Inverted V incision which was statistically significant. Inverted V (Chevron) incision gives minimal SIA.

  20. COMPARISON OF POSTOP SIA IN MSICS WITH STRAIGHT INCISION VERSUS FROWN INCISION

    Directory of Open Access Journals (Sweden)

    Shayana Bhumbla

    2017-05-01

    Full Text Available BACKGROUND Surgically-Induced Astigmatism (SIA is one of the commonest causes of poor postoperative vision even after uneventful cataract surgery. Recent advances have led to a newer concept of “refractive cataract surgery.” The aim of the study is to study the comparison of postop SIA in Manual Small Incision Cataract Surgery (MSICS with straight versus frown incision. MATERIALS AND METHODS 50 patients of cataract were divided into 2 groups (25 each - group A underwent MSICS with 6 mm straight incision, group B underwent MSICS with 6 mm frown incision. BCVA, keratometry readings were recorded with auto kerato-refractometer preop, at 1 week, 1 month, 3 months and SIA was calculated with SIA calculator version 2.1, a free software program. RESULTS Mean SIA in group A and B were - 1.14D versus 0.92D at 1 week; 1.26D versus 0.97D at 1 month; 1.29D versus 0.95D at 3 months. The difference was statistically significant at each follow up visit (p<0.05. CONCLUSION Frown incision gives lesser SIA than straight incision in MSICS.

  1. Mast Quadrant-assisted Minimally Invasive Modified Transforaminal Lumbar Interbody Fusion: Single Incision Versus Double Incision

    Directory of Open Access Journals (Sweden)

    Xin-Lei Xia

    2015-01-01

    Full Text Available Background: The concept of minimally invasive techniques is to make every effort to reduce tissue damage. Certainly, reducing skin incision is an important part of these techniques. This study aimed to investigate the clinical feasibility of Mast Quadrant-assisted modified transforaminal lumbar interbody fusion (TLIF with a small single posterior median incision. Methods: During the period of March 2011 to March 2012, 34 patients with single-segment degenerative lumbar disease underwent the minimally invasive modified TLIF assisted by Mast Quadrant with a small single posterior median incision (single incision group. The cases in this group were compared to 37 patients with single-segment degenerative lumbar disease in the double incision group. The perioperative conditions of patients in these two groups were statistically analyzed and compared. The Oswestry Disability Index (ODI scores, Visual Analog Scale (VAS scores, and sacrospinalis muscle damage evaluation indicators before operation and 3, 12 months postoperation were compared. Results: A total of 31 and 35 cases in the single incision and double incision groups, respectively, completed at least 12 months of systemic follow-up. The differences in perioperative conditions between the two groups were not statistically significant. The incision length of the single incision group was significantly shorter than that of the double incision group (P < 0.01. The ODI and VAS scores of patients in both groups improved significantly at 3 and 12 months postoperation. However, these two indicators at 3 and 12 months postoperation and the sacrospinalis muscle damage evaluation indicators at 3 months postoperation did not differ significantly between the two groups (P ≥ 0.05. Conclusions: Mast Quadrant-assisted modified TLIF with a small single posterior median incision has excellent clinical feasibility compared to minimally invasive TLIF with a double paramedian incision.

  2. Comparison of electrocautery incision with scalpel incision in midline abdominal surgery - A double blind randomized controlled trial.

    Science.gov (United States)

    Prakash, Lalgudi Dorairajan; Balaji, Nitesh; Kumar, Sathasivam Suresh; Kate, Vikram

    2015-07-01

    To compare the electrocautery incision with scalpel incision in patients undergoing abdominal surgery using a midline incision with respect to incision time, blood loss during incision, postoperative incision site pain and wound infection. Patients undergoing midline abdominal surgery were randomized into electrocautery and scalpel groups. The incision dimensions, incision time and blood loss during incision were noted intraoperatively. Postoperative pain and wound infection were recorded on every postoperative day for one week. 41 patients in each of the two groups were analyzed. Gender and age distribution was similar in both the groups. The mean incision time per unit wound area in the electrocautery group and scalpel group was 9.40 ± 3.37 s/cm(2) and 9.07 ± 3.40 s/cm(2) (p = 0.87) respectively. The mean blood loss per unit wound area was significantly lower in the electrocautery group at 6.46 ± 3.94 ml when compared to that of 23.40 ± 15.28 ml in the scalpel group (p= electrocautery and scalpel groups (14.63% vs. 12.19%; p = 0.347). With a comparable Postoperative incision site pain, wound infection rate and significantly lower blood loss with the equal time taken for the incision, electrocautery can be considered safe and effective in making skin incision in midline laparotomy compared to scalpel incision. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  3. Craniosynostosis incision: scalpel or cautery?

    Science.gov (United States)

    Wood, Jeyhan S; Kittinger, Benjamin J; Perry, Victor L; Adenola, Adeyemi; van Aalst, John A

    2014-07-01

    There is an ongoing debate regarding the optimal instrument for scalp incisions: the scalpel or electrocautery. The argument generally focuses on improved healing after an incision made with a knife and decreased bleeding when using electrocautery. This study compares the use of scalpel and electrocautery in making coronal incisions for patients undergoing surgical correction of craniosynostosis. The outcome metric used is wound healing within 6 months after surgery. All patients presenting to the University of North Carolina Children's Hospital with craniosynostosis between July 1, 2007 and January 1, 2010 requiring a coronal incision for surgical correction were prospectively enrolled. In all of these patients, half of the coronal incision was made with knife; the other half, with needle tip cautery. Side of the incision was specified at the time of surgery in the operative report. Patients were excluded from the study if the instrument for incision was not specified or if only 1 modality was used for the entire incision. Sixty-eight patients underwent cranial vault reconstruction, of which 58 met inclusion criteria. Of the 58 matched pairs, 55 were analyzed statistically. The 3 excluded cases were those who had midline complications. There were 17 wound complications (15%): 8 in the knife group, 6 in the cautery group, and 3 at midline (with indeterminate side for the problem). We found no statistically significant difference in wound healing between incisions made with a knife or with electrocautery.

  4. Overlapping sphincteroplasty and posterior repair.

    Science.gov (United States)

    Crane, Andrea K; Myers, Erinn M; Lippmann, Quinn K; Matthews, Catherine A

    2014-12-01

    Knowledge of how to anatomically reconstruct extensive posterior-compartment defects is variable among gynecologists. The objective of this video is to demonstrate an effective technique of overlapping sphincteroplasty and posterior repair. In this video, a scripted storyboard was constructed that outlines the key surgical steps of a comprehensive posterior compartment repair: (1) surgical incision that permits access to posterior compartment and perineal body, (2) dissection of the rectovaginal space up to the level of the cervix, (3) plication of the rectovaginal muscularis, (4) repair of internal and external anal sphincters, and (5) reconstruction of the perineal body. Using a combination of graphic illustrations and live video footage, tips on repair are highlighted. The goals at the end of repair are to: (1) have improved vaginal caliber, (2) increase rectal tone along the entire posterior vaginal wall, (3) have the posterior vaginal wall at a perpendicular plane to the perineal body, (4) reform the hymenal ring, and (5) not have an overly elongated perineal body. This video provides a step-by-step guide on how to perform an overlapping sphincteroplasty and posterior repair.

  5. Laparoendoscopic single-site extraperitoneal inguinal hernia repair: initial experience in 10 patients.

    Science.gov (United States)

    Do, Minh; Liatsikos, Evangelos; Beatty, John; Haefner, Tim; Dunn, Ian; Kallidonis, Panagiotis; Stolzenburg, Jens-Uwe

    2011-06-01

    Recent technical advances and a trend toward laparoscopic single incision surgery have led us to explore the feasibility of laparoendoscopic single-site (LESS) hernia repair. We present our technique and initial experience with LESS extraperitoneal inguinal hernia repair in 10 consecutive men with unilateral inguinal hernias. Age range was 43.7 (28-64) years. Mean body mass index was 28 (range 24-30). Six were left inguinal hernias. There were six indirect and four direct hernias. Three patients had undergone previous open appendectomy. Incarcerated or bilateral hernias were excluded from our initial series. All cases were performed by three surgeons who were experienced in conventional totally extraperitoneal laparoscopic hernia repair as well as experienced in LESS. A literature review of current single-port inguinal hernia repair data is also presented. The mean operative time was 53 minutes (range 45-65  min). The average length of skin incision was 2.8  cm (range 2.3-3.2  cm). No drain was necessary in any of the patients, while no recordable bleeding was observed. There were no intraoperative or immediate postoperative complications. Hospitalization period was 2 days for all patients. After a limited follow-up of 1 month, there have been no recurrences and no complaints of testicular pain. The results of the current series compare favorably with those found in a literature review. LESS extraperitoneal inguinal hernia repair is both feasible and safe, although more technically demanding than its conventional laparoscopic counterpart. Although the cosmetic result with the former approach may prove superior, there are standing questions regarding the complications and long-term outcome. Randomized and if possible blinded trials that compare conventional and single-incision laparoscopic hernia repair may help to distinguish the most advantageous technique.

  6. The cutting edges in DNA repair, licensing, and fidelity: DNA and RNA repair nucleases sculpt DNA to measure twice, cut once.

    Science.gov (United States)

    Tsutakawa, Susan E; Lafrance-Vanasse, Julien; Tainer, John A

    2014-07-01

    To avoid genome instability, DNA repair nucleases must precisely target the correct damaged substrate before they are licensed to incise. Damage identification is a challenge for all DNA damage response proteins, but especially for nucleases that cut the DNA and necessarily create a cleaved DNA repair intermediate, likely more toxic than the initial damage. How do these enzymes achieve exquisite specificity without specific sequence recognition or, in some cases, without a non-canonical DNA nucleotide? Combined structural, biochemical, and biological analyses of repair nucleases are revealing their molecular tools for damage verification and safeguarding against inadvertent incision. Surprisingly, these enzymes also often act on RNA, which deserves more attention. Here, we review protein-DNA structures for nucleases involved in replication, base excision repair, mismatch repair, double strand break repair (DSBR), and telomere maintenance: apurinic/apyrimidinic endonuclease 1 (APE1), Endonuclease IV (Nfo), tyrosyl DNA phosphodiesterase (TDP2), UV Damage endonuclease (UVDE), very short patch repair endonuclease (Vsr), Endonuclease V (Nfi), Flap endonuclease 1 (FEN1), exonuclease 1 (Exo1), RNase T and Meiotic recombination 11 (Mre11). DNA and RNA structure-sensing nucleases are essential to life with roles in DNA replication, repair, and transcription. Increasingly these enzymes are employed as advanced tools for synthetic biology and as targets for cancer prognosis and interventions. Currently their structural biology is most fully illuminated for DNA repair, which is also essential to life. How DNA repair enzymes maintain genome fidelity is one of the DNA double helix secrets missed by James Watson and Francis Crick, that is only now being illuminated though structural biology and mutational analyses. Structures reveal motifs for repair nucleases and mechanisms whereby these enzymes follow the old carpenter adage: measure twice, cut once. Furthermore, to measure

  7. Incision integrity and postoperative outcomes after microcoaxial phacoemulsification performed using 2 incision-dependent systems.

    Science.gov (United States)

    Vasavada, Vaishali; Vasavada, Abhay R; Vasavada, Viraj A; Srivastava, Samaresh; Gajjar, Devarshi U; Mehta, Siddharth

    2013-04-01

    To compare incision integrity and clinical outcomes of 2 microcoaxial phacoemulsification systems. Iladevi Cataract & IOL Research Centre, Ahmedabad, India. Prospective randomized clinical trial. Eyes were randomized to have phacoemulsification using a 1.8 mm clear corneal incision (CCI) system (Group 1, Stellaris system) or a 2.2 mm CCI system (Group 2, Intrepid Infiniti system). Incision enlargement at end of surgery was measured. At the conclusion of surgery, trypan blue was applied over the conjunctival surface, anterior chamber aspirate withdrawn, and ingress into anterior chamber measured. Postoperative observations included evaluation of the CCI using anterior segment optical coherence tomography (AS-OCT), change in central corneal thickness (CCT), and anterior segment inflammation at 1 day, 1 week, and 1 month and endothelial cell loss and surgically induced astigmatism (SIA) at 3 months. Incision enlargement (P.05). At the end of surgery, it is not the initial incision size alone but also the distortion of the incision during subsequent stages of surgery that determine the integrity of the CCI. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Assessment and reduction of diaphragmatic tension during hiatal hernia repair.

    Science.gov (United States)

    Bradley, Daniel Davila; Louie, Brian E; Farivar, Alexander S; Wilshire, Candice L; Baik, Peter U; Aye, Ralph W

    2015-04-01

    During hiatal hernia repair there are two vectors of tension: axial and radial. An optimal repair minimizes the tension along these vectors. Radial tension is not easily recognized. There are no simple maneuvers like measuring length that facilitate assessment of radial tension. The aims of this project were to: (1) establish a simple intraoperative method to evaluate baseline tension of the diaphragmatic hiatal muscle closure; and, (2) assess if tension is reduced by relaxing maneuvers and if so, to what degree. Diaphragmatic characteristics and tension were assessed during hiatal hernia repair with a tension gage. We compared tension measured after hiatal dissection and after relaxing maneuvers were performed. Sixty-four patients (29 M:35F) underwent laparoscopic hiatal hernia repair. Baseline hiatal width was 2.84 cm and tension 13.6 dag. There was a positive correlation between hiatal width and tension (r = 0.55) but the strength of association was low (r (2) = 0.31). Four different hiatal shapes (slit, teardrop, "D", and oval) were identified and appear to influence tension and the need for relaxing incision. Tension was reduced by 35.8 % after a left pleurotomy (12 patients); by 46.2 % after a right crural relaxing incision (15 patients); and by 56.1 % if both maneuvers were performed (6 patients). Tension on the diaphragmatic hiatus can be measured with a novel device. There was a limited correlation with width of the hiatal opening. Relaxing maneuvers such as a left pleurotomy or a right crural relaxing incision reduced tension. Longer term follow-up will determine whether outcomes are improved by quantifying and reducing radial tension.

  9. Benzene-derived N2-(4-hydroxyphenyl)-deoxyguanosine adduct: UvrABC incision and its conformation in DNA

    Energy Technology Data Exchange (ETDEWEB)

    Hang, Bo; Rodriguez, Ben; Yang, Yanu; Guliaev, Anton B.; Chenna, Ahmed

    2010-06-14

    Benzene, a ubiquitous human carcinogen, forms DNA adducts through its metabolites such as p-benzoquinone (p-BQ) and hydroquinone (HQ). N(2)-(4-Hydroxyphenyl)-2'-deoxyguanosine (N(2)-4-HOPh-dG) is the principal adduct identified in vivo by (32)P-postlabeling in cells or animals treated with p-BQ or HQ. To study its effect on repair specificity and replication fidelity, we recently synthesized defined oligonucleotides containing a site-specific adduct using phosphoramidite chemistry. We here report the repair of this adduct by Escherichia coli UvrABC complex, which performs the initial damage recognition and incision steps in the nucleotide excision repair (NER) pathway. We first showed that the p-BQ-treated plasmid was efficiently cleaved by the complex, indicating the formation of DNA lesions that are substrates for NER. Using a 40-mer substrate, we found that UvrABC incises the DNA strand containing N(2)-4-HOPh-dG in a dose- and time-dependent manner. The specificity of such repair was also compared with that of DNA glycosylases and damage-specific endonucleases of E. coli, both of which were found to have no detectable activity toward N(2)-4-HOPh-dG. To understand why this adduct is specifically recognized and processed by UvrABC, molecular modeling studies were performed. Analysis of molecular dynamics trajectories showed that stable G:C-like hydrogen bonding patterns of all three Watson-Crick hydrogen bonds are present within the N(2)-4-HOPh-G:C base pair, with the hydroxyphenyl ring at an almost planar position. In addition, N(2)-4-HOPh-dG has a tendency to form more stable stacking interactions than a normal G in B-type DNA. These conformational properties may be critical in differential recognition of this adduct by specific repair enzymes.

  10. Upconverting and NIR emitting rare earth based nanostructures for NIR-bioimaging

    Science.gov (United States)

    Hemmer, Eva; Venkatachalam, Nallusamy; Hyodo, Hiroshi; Hattori, Akito; Ebina, Yoshie; Kishimoto, Hidehiro; Soga, Kohei

    2013-11-01

    In recent years, significant progress was achieved in the field of nanomedicine and bioimaging, but the development of new biomarkers for reliable detection of diseases at an early stage, molecular imaging, targeting and therapy remains crucial. The disadvantages of commonly used organic dyes include photobleaching, autofluorescence, phototoxicity and scattering when UV (ultraviolet) or visible light is used for excitation. The limited penetration depth of the excitation light and the visible emission into and from the biological tissue is a further drawback with regard to in vivo bioimaging. Lanthanide containing inorganic nanostructures emitting in the near-infrared (NIR) range under NIR excitation may overcome those problems. Due to the outstanding optical and magnetic properties of lanthanide ions (Ln3+), nanoscopic host materials doped with Ln3+, e.g. Y2O3:Er3+,Yb3+, are promising candidates for NIR-NIR bioimaging. Ln3+-doped gadolinium-based inorganic nanostructures, such as Gd2O3:Er3+,Yb3+, have a high potential as opto-magnetic markers allowing the combination of time-resolved optical imaging and magnetic resonance imaging (MRI) of high spatial resolution. Recent progress in our research on over-1000 nm NIR fluorescent nanoprobes for in vivo NIR-NIR bioimaging will be discussed in this review.In recent years, significant progress was achieved in the field of nanomedicine and bioimaging, but the development of new biomarkers for reliable detection of diseases at an early stage, molecular imaging, targeting and therapy remains crucial. The disadvantages of commonly used organic dyes include photobleaching, autofluorescence, phototoxicity and scattering when UV (ultraviolet) or visible light is used for excitation. The limited penetration depth of the excitation light and the visible emission into and from the biological tissue is a further drawback with regard to in vivo bioimaging. Lanthanide containing inorganic nanostructures emitting in the near

  11. Structural and Functional Studies on Nucleotide Excision Repair From Recognition to Incision.

    Energy Technology Data Exchange (ETDEWEB)

    Caroline Kisker

    2001-01-01

    Maintenance of the correct genetic information is crucial for all living organisms because mutations are the primary cause of hereditary diseases, as well as cancer and may also be involved in aging. The importance of genomic integrity is underscored by the fact that 80 to 90% of all human cancers are ultimately due to DNA damage. Among the different repair mechanisms that have evolved to protect the genome, nucleotide excision repair (NER) is a universal pathway found in all organisms. NER removes a wide variety of bulky DNA adducts including the carcinogenic cyclobutane pyrimidine dimers induced by UV radiation, benzo(a)pyrene-guanine adducts caused by smoking and the guanine-cisplatin adducts induced by chemotherapy. The importance of this repair mechanism is reflected by three severe inherited diseases in humans, which are due to defects in NER: xeroderma pigmentosum, Cockayne's syndrome and trichothiodystrophy.

  12. Relative Contribution of nirK- and nirS- Bacterial Denitrifiers as Well as Fungal Denitrifiers to Nitrous Oxide Production from Dairy Manure Compost.

    Science.gov (United States)

    Maeda, Koki; Toyoda, Sakae; Philippot, Laurent; Hattori, Shohei; Nakajima, Keiichi; Ito, Yumi; Yoshida, Naohiro

    2017-12-19

    The relative contribution of fungi, bacteria, and nirS and nirK denirifiers to nitrous oxide (N 2 O) emission with unknown isotopic signature from dairy manure compost was examined by selective inhibition techniques. Chloramphenicol (CHP), cycloheximide (CYH), and diethyl dithiocarbamate (DDTC) were used to suppress the activity of bacteria, fungi, and nirK-possessing denitrifiers, respectively. Produced N 2 O were surveyed to isotopocule analysis, and its 15 N site preference (SP) and δ 18 O values were compared. Bacteria, fungi, nirS, and nirK gene abundances were compared by qPCR. The results showed that N 2 O production was strongly inhibited by CHP addition in surface pile samples (82.2%) as well as in nitrite-amended core samples (98.4%), while CYH addition did not inhibit the N 2 O production. N 2 O with unknown isotopic signature (SP = 15.3-16.2‰), accompanied by δ 18 O (19.0-26.8‰) values which were close to bacterial denitrification, was also suppressed by CHP and DDTC addition (95.3%) indicating that nirK denitrifiers were responsible for this N 2 O production despite being less abundant than nirS denitrifiers. Altogether, our results suggest that bacteria are important for N 2 O production with different SP values both from compost surface and pile core. However, further work is required to decipher whether N 2 O with unknown isotopic signature is mostly due to nirK denitrifiers that are taxonomically different from the SP-characterized strains and therefore have different SP values rather than also being interwoven with the contribution of the NO-detoxifying pathway and/or of co-denitrification.

  13. Single-incision total laparoscopic hysterectomy

    Directory of Open Access Journals (Sweden)

    Sinha Rakesh

    2011-01-01

    Full Text Available Single-incision laparoscopic surgery is an alternative to conventional multiport laparoscopy. Single-access laparoscopy using a transumbilical port affords maximum cosmetic benefits because the surgical incision is hidden in the umbilicus. The advantages of single-access laparoscopic surgery may include less bleeding, infection, and hernia formation and better cosmetic outcome and less pain. The disadvantages and limitations include longer surgery time, difficulty in learning the technique, and the need for specialized instruments. Ongoing refinement of the surgical technique and instrumentation is likely to expand its role in gynecologic surgery in the future. We perform single-incision total laparoscopic hysterectomy using three ports in the single transumbilical incision.

  14. Sharp incision of the anterior mitral leaflet due to penetrating trauma - Report of a case and long-term follow-up

    NARCIS (Netherlands)

    de Boer, HD; Hamer, HPM; Ebels, T

    A case is described of sharp incision of the anterior leaflet of the mitral valve, due to penetrating trauma to the chest with a knife. The lesion of the mitral leaflet was diagnosed with echocardiography and successfully repaired with autologous pericardial tissue. Follow up after 15 years showed

  15. Postoperative Granulomas at Liposuction Incision Sites.

    Science.gov (United States)

    Weniger, Frederick G; White, Peter F; Barrero Castedo, Carlos E

    2016-02-01

    Since most liposuction incisions heal uneventfully, difficult healing in such incisions must be investigated. In the cases of two gynecomastia liposuction patients in which a water-based lubricating gel was used on the liposuction incisions, the incisions failed to heal. For both patients, workup uncovered palisading granulomas at the lateral inframammary fold incision sites several months after otherwise successful surgeries. These two cases are presented and the previous literature is reviewed, with consideration given to the etiology and prevention of such granulomas. LEVEL OF EVIDENCE 5: Risk. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  16. Single incision pediatric endoscopic surgery: advantages of relatively large incision

    International Nuclear Information System (INIS)

    Yilmaz, E.; Afsarlar, E.; Karaman, I.

    2015-01-01

    To describe Single Incision Pediatric Endoscopic Surgery (SIPES) performed on children with various diagnoses, emphasizing its advantages. Study Design: An observational case series. Place and Duration of Study: Department of Pediatric Surgery, Dr. Sami Ulus Maternity and Child Health Hospital, Ankara, Turkey, from January 2011 to November 2014. Methodology: A review of patient charts was conducted in which SIPES was preferred as the surgical procedure. Patient demographics, operative details, operative time, clinical outcomes, postoperative pain and cosmesis were analyzed. Results: SIPES was performed on 45 patients (21 girls, 24 boys). Thirty-three appendectomies, 5 varicocelectomies, 3 oophorectomies, 2 ovarian and one paratubal cyst excision, and one fallopian tube excision were performed. All except one procedures were performed through our standard 2cm umbilical vertical or smile incision. In 18 cases, abdominal irrigation/aspiration was easily performed through the existing larger incision, as is done with open surgical technique. None of the patients had early postoperative shoulder/back pain since complete disinflation of CO/sub 2/ could be ensured. All of the patients/parents were satisfied with the cosmesis. Conclusion: SIPES has the advantages of limiting the surgical scar to within the umbilicus and providing easy disinflation of CO/sub 2/, allowing intraabdominal cleaning and extraction of large volume tissue samples through a single large umbilical incision. (author)

  17. Assessment of corneal astigmatism following frown and straight incision forms in sutureless manual small incision cataract surgery

    Directory of Open Access Journals (Sweden)

    Amedo AO

    2016-04-01

    Full Text Available Angela Ofeibea Amedo, Kwadwo Amoah, Nana Yaa Koomson, David Ben Kumah, Eugene Appenteng Osae Department of Optometry and Visual Science, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana Abstract: To investigate which of two tunnel incision forms (frown versus straight in sutureless manual small incision cataract surgery creates more corneal astigmatism. Sixty eyes of 60 patients who had consented to undergo cataract surgery and to partake in this study were followed from baseline through >12-week postoperative period. Values of preoperative and postoperative corneal astigmatism for the 60 eyes, measured with a Bausch and Lomb keratometer, were extracted from the patients’ cataract surgery records. Residual astigmatism was computed as the difference between preoperative and postoperative keratometry readings. Visual acuity was assessed during the preoperative period and at each postoperative visit with a Snellen chart at 6 m. Fifty eyes of 50 patients were successfully followed-up on. Overall, the mean residual astigmatism was 0.75±0.12 diopters. The differences in mean residual astigmatism between the two different incision groups were statistically significant (t [48]=6.33, P<0.05; frown incision group recorded 1.00±0.12 diopters, whereas the straight incision group recorded 0.50±0.12 diopters. No significant difference was observed between male and female groups (t [48]=0.24, P>0.05. Residual corneal astigmatism in the frown incision group was significantly higher than in the straight incision group. Fisher’s exact test did not reveal a significant association between incision forms and visual acuity during the entire postoperative period (P>0.05. Keywords: cataract, residual corneal astigmatism, frown incision, straight incision

  18. Small Incision Cataract Surgery (SICS with Clear Corneal Incision and SICS with Scleral Incision – A Comparative Study

    Directory of Open Access Journals (Sweden)

    Md Shafiqul Alam

    2014-01-01

    Full Text Available Background: Age related cataract is the leading cause of blindness and visual impairment throughout the world. With the advent of microsurgical facilities simple cataract extraction surgery has been replaced by small incision cataract surgery (SICS with posterior chamber intra ocular lens implant, which can be done either with clear corneal incision or scleral incision. Objective: To compare the post operative visual outcome in these two procedures of cataract surgery. Materials and method: This comparative study was carried out in the department of Ophthalmology, Delta Medical College & Hospital, Dhaka, Bangladesh, during the period of January 2010 to December 2012. Total 60 subjects indicated for age related cataract surgery irrespective of sex with the age range of 40-80 years with predefined inclusion and exclusion criteria were enrolled in the study. Subjects were randomly and equally distributed in 2 groups; Group A for SICS with clear corneal incision and group B for SICS with scleral incision. Post operative visual out come was evaluated by determining visual acuity and astigmatism in different occasions and was compared between groups. Statistical analysis was done by SPSS for windows version12. Results: The highest age incidence (43.3% was found between 61 to 70 years of age group. Among study subjects 40 were male and 20 were female. Preoperative visual acuity and astigmatism were evenly distributed between groups. Regarding postoperative unaided visual outcome, 6/12 or better visual acuity was found in 19.98% cases in group A and 39.6% cases in group B at 1st week. At 6th week 6/6 vision was found in 36.3% in Group A and 56.1% in Group B and 46.2% in group A and 66% in group B without and with correction respectively. With refractive correction, 6/6 vision was attained in 60% subjects of group A and 86.67% of group B at 8th week. Post operative visual acuity was statistically significant in all occasions. Postoperative astigmatism of

  19. Inhibition of nucleotide excision repair by fludarabine in normal lymphocytes in vitro, measured by the alkaline single cell gel electrophoresis (comet) assay

    Energy Technology Data Exchange (ETDEWEB)

    Yamauchi, Takahiro; Kawai, Yasukazu; Ueda, Takanori [Fukui Medical Univ., Matsuoka (Japan)

    2002-05-01

    Alkylating agents or platinum analogues initiate several excision repair mechanisms, which involve incision of the DNA strand, excision of the damaged nucleotide, gap filling by DNA resynthesis, and rejoining by ligation. The previous study described that nucleotide excision repair permitted incorporation of fludarabine nucleoside (F-area-A) into the repair patch, thereby inhibiting the DNA resynthesis. In the present study, to clarify the repair kinetics in view of the inhibition by F-ara-A, normal lymphocytes were stimulated to undergo nucleotide excision repair by ultraviolet C (UV) irradiation in the presence or absence of F-ara-A. The repair kinetics were determined as DNA single strand breaks resulting from the incision and the rejoining using the alkaline single cell gel electrophoresis (comet) assay. DNA resynthesis was evaluated in terms of the uptake of tritiated thymidine into DNA. The lymphocytes initiated the incision step maximally at 1 h, and completed the rejoining process within 4 h after UV exposure. UV also initiated thymidine uptake, which increased time-dependently and reached a plateau at 4 h. A 2-h pre-incubation with F-ara-A inhibited the repair in a concentration-dependent manner, with the maximal inhibition by 5 {mu}M. This inhibitory effect was demonstrated by the reduction of the thymidine uptake and by the inhibition of the rejoining. A DNA polymerase inhibitor, aphidicolin, and a ribonucleotide reductase inhibitor, hydroxyurea, were not so inhibitory to the repair process as F-ara-A at equimolar concentrations. The present findings suggest that inhibition of nucleotide excision repair may represent a novel therapeutic strategy against cancer, especially in the context of resistant cells with an increased repair capacity. (author)

  20. Lateral Nail Fold Incision Technique for Venous Anastomosis in Fingertip Replantation.

    Science.gov (United States)

    Jeon, Byung-Joon; Yang, Jae-Won; Roh, Si Young; Ki, Sae Hwi; Lee, Dong Chul; Kim, Jin Soo

    2016-01-01

    Successful venous anastomosis is one of the most important factors in fingertip replantation. Volar veins in the fingertip course proximally in a random pattern, which makes it difficult to find out the exact locations. Although dorsal veins in the lateral nail fold have constant location and adequate diameter for anastomosis, they have been known as hard to dissect from the immobile subcutaneous tissue. The authors present a new lateral nail fold incision technique for venous anastomosis in the fingertip amputations. From February 2010 to October 2010, 9 replantations using the new incision and venous anastomosis technique were performed in 9 patients. The levels of amputations were from the nail base to half of the nail bed. After repairing the proper digital arteries, a skin incision was made along the junction between the lateral nail fold and nail bed. Careful dissection was performed to isolate the veins in the lateral nail fold. After evaluation of the suitability of the vessel, venous anastomosis was performed. Seven male and 2 female patients were enrolled in this study. Appropriate dorsal veins for anastomosis could be found in 8 of 9 patients. All the replanted stumps survived without venous congestion and following additional procedures. A sizable volar or dorsal vein could not be found in 1 patient. The salvage technique was required in this patient. Dorsal veins in the lateral nail fold can be found easily because of the constant anatomical location. The new incision on the lateral nail fold provides not only sufficient operative field for anastomosis but also additional opportunity of successful venous anastomosis in the selected cases. The authors, therefore, propose this technique as an effective method for an alternative venous anastomosis in the zone I replantation.

  1. Human DNA repair and recombination genes

    International Nuclear Information System (INIS)

    Thompson, L.H.; Weber, C.A.; Jones, N.J.

    1988-09-01

    Several genes involved in mammalian DNA repair pathways were identified by complementation analysis and chromosomal mapping based on hybrid cells. Eight complementation groups of rodent mutants defective in the repair of uv radiation damage are now identified. At least seven of these genes are probably essential for repair and at least six of them control the incision step. The many genes required for repair of DNA cross-linking damage show overlap with those involved in the repair of uv damage, but some of these genes appear to be unique for cross-link repair. Two genes residing on human chromosome 19 were cloned from genomic transformants using a cosmid vector, and near full-length cDNA clones of each gene were isolated and sequenced. Gene ERCC2 efficiently corrects the defect in CHO UV5, a nucleotide excision repair mutant. Gene XRCC1 normalizes repair of strand breaks and the excessive sister chromatid exchange in CHO mutant EM9. ERCC2 shows a remarkable /approximately/52% overall homology at both the amino acid and nucleotide levels with the yeast RAD3 gene. Evidence based on mutation induction frequencies suggests that ERCC2, like RAD3, might also be an essential gene for viability. 100 refs., 4 tabs

  2. Improving NIR snow pit stratigraphy observations by introducing a controlled NIR light source

    Science.gov (United States)

    Dean, J.; Marshall, H.; Rutter, N.; Karlson, A.

    2013-12-01

    Near-infrared (NIR) photography in a prepared snow pit measures mm-/grain-scale variations in snow structure, as reflectivity is strongly dependent on microstructure and grain size at the NIR wavelengths. We explore using a controlled NIR light source to maximize signal to noise ratio and provide uniform incident, diffuse light on the snow pit wall. NIR light fired from the flash is diffused across and reflected by an umbrella onto the snow pit; the lens filter transmits NIR light onto the spectrum-modified sensor of the DSLR camera. Lenses are designed to refract visible light properly, not NIR light, so there must be a correction applied for the subsequent NIR bright spot. To avoid interpolation and debayering algorithms automatically performed by programs like Adobe's Photoshop on the images, the raw data are analyzed directly in MATLAB. NIR image data show a doubling of the amount of light collected in the same time for flash over ambient lighting. Transitions across layer boundaries in the flash-lit image are detailed by higher camera intensity values than ambient-lit images. Curves plotted using median intensity at each depth, normalized to the average profile intensity, show a separation between flash- and ambient-lit images in the upper 10-15 cm; the ambient-lit image curve asymptotically approaches the level of the flash-lit image curve below 15cm. We hypothesize that the difference is caused by additional ambient light penetrating the upper 10-15 cm of the snowpack from above and transmitting through the wall of the snow pit. This indicates that combining NIR ambient and flash photography could be a powerful technique for studying penetration depth of radiation as a function of microstructure and grain size. The NIR flash images do not increase the relative contrast at layer boundaries; however, the flash more than doubles the amount of recorded light and controls layer noise as well as layer boundary transition noise.

  3. [EFFECTIVENESS OF ADVANCED SKIN FLAP AND V-SHAPED VENTRAL INCISION ALONG THE ROOT OF PENILE SHAFT FOR CONCEALED PENIS].

    Science.gov (United States)

    Lin, Junshan; Li, Dumiao; Zhang, Jianxing; Wu, Qiang; Xu, Yali; Lin, Li

    2015-09-01

    To investigate effectiveness of advanced skin flap and V-shaped ventral incision along the root of penile shaft for concealed penis in children. Between July 2007 and January 2015, 121 boys with concealed penis were treated with advanced skin flap and V-shaped ventral incision along the root of penile shaft. The age varied from 18 months to 13 years (mean, 7.2 years). Repair was based on a vertical incision in median raphe, complete degloving of penis and tacking its base to the dermis of the skin. Advanced skin flap and a V-shaped ventral incision along the root of penile shaft were used to cover the penile shaft. The operation time ranged from 60 to 100 minutes (mean, 75 minutes). Disruption of wound occurred in 1 case, and was cured after dressing change; and primary healing of incision was obtained in the others. The follow-up period ranged from 3 months to 7 years (median, 24 months). All patients achieved good to excellent cosmetic results with a low incidence of complications. The results were satisfactory in exposure of penis and prepuce appearance. No obvious scar was observed. The penis had similar appearance to that after prepuce circumcision. A combination of advanced skin flap and V-shaped ventral incision along the root of penile shaft is a simple, safe, and effective procedure for concealed penis with a similar appearance result to the prepuce circumcision.

  4. The Gift Box Open Achilles Tendon Repair Method: A Retrospective Clinical Series.

    Science.gov (United States)

    Labib, Sameh A; Hoffler, C Edward; Shah, Jay N; Rolf, Robert H; Tingan, Alexis

    2016-01-01

    Previous biomechanical studies have shown that the gift box technique for open Achilles tendon repair is twice as strong as a Krackow repair. The technique incorporates a paramedian skin incision with a midline paratenon incision, and a modification of the Krackow stitch is used to reinforce the repair. The wound is closed in layers such that the paratenon repair is offset from paramedian skin incision, further protecting the repair. The present study retrospectively reviews the clinical results for a series of patients who underwent the gift box technique for treatment of acute Achilles tendon ruptures from March 2002 to April 2007. The patients completed the Foot Function Index and the American Orthopaedic Foot and Ankle Society ankle-hindfoot scale. The tendon width and calf circumference were measured bilaterally and compared using paired t tests with a 5% α level. A total of 44 subjects, mean age 37.5 ± 8.6 years, underwent surgery approximately 10.8 ± 6.5 days after injury. The response rate was 35 (79.54%) patients for the questionnaire and 20 (45.45%) for the examination. The mean follow-up period was 35.7 ± 20.1 months. The complications included one stitch abscess, persistent pain, and keloid formation. One (2.86%) respondent reported significant weakness. Five (14.29%) respondents indicated persistent peri-incisional numbness. The range of motion was full or adequate. The mean American Orthopaedic Foot and Ankle Society ankle-hindfoot scale score was 93.2 ± 6.8) and the mean Foot Function Index score was 7.0 ± 10.5. The calf girth and tendon width differences were statistically significantly between the limbs. The patients reported no repeat ruptures, sural nerve injuries, dehiscence, or infections. We present the outcomes data from patients who had undergone this alternative technique for Achilles tendon repair. The technique is reproducible, with good patient satisfaction and return to activity. The results compared well with the historical

  5. Laparoscopic hernia repair and bladder injury.

    Science.gov (United States)

    Dalessandri, K M; Bhoyrul, S; Mulvihill, S J

    2001-01-01

    Bladder injury is a complication of laparoscopic surgery with a reported incidence in the general surgery literature of 0.5% and in the gynecology literature of 2%. We describe how to recognize and treat the injury and how to avoid the problem. We report two cases of bladder injury repaired with a General Surgical Interventions (GSI) trocar and a balloon device used for laparoscopic extraperitoneal inguinal hernia repair. One patient had a prior appendectomy; the other had a prior midline incision from a suprapubic prostatectomy. We repaired the bladder injury, and the patients made a good recovery. When using the obturator and balloon device, it is important to stay anterior to the preperitoneal space and bladder. Prior lower abdominal surgery can be considered a relative contraindication to extraperitoneal laparoscopic hernia repair. Signs of gas in the Foley bag or hematuria should alert the surgeon to a bladder injury. A one- or two-layer repair of the bladder injury can be performed either laparoscopically or openly and is recommended for a visible injury. Mesh repair of the hernia can be completed provided no evidence exists of urinary tract infection. A Foley catheter is placed until healing occurs.

  6. Modified incision for maxillectomy: our experience.

    Science.gov (United States)

    Bhavana, Kranti; Tyagi, Isha; Ramani, Mukesh Kumar

    2012-06-01

    Radical maxillectomy has usually been done by the classical Weber Ferguson incision since age old times and still is being used widely due to its advantage of excellent exposure and minimal scarring as the incision follows the natural skin crease. In our modification of radical maxillectomy incision we avoid a scar on the midface by performing a midface degloving and combining it with a subconjunctival eye incision thus avoiding any cosmetic deformity and associated eye complication. It also avoids the late complication of cutaneous fistula following radiotherapy to these areas and due to early healing of the wound, early radiotherapy can be started.

  7. Penetrating and Intrastromal Corneal Arcuate Incisions in Rabbit and Human Cadaver Eyes: Manual Diamond Blade and Femtosecond Laser-Created Incisions.

    Science.gov (United States)

    Gray, Brad; Binder, Perry S; Huang, Ling C; Hill, Jim; Salvador-Silva, Mercedes; Gwon, Arlene

    2016-07-01

    To compare morphologic differences between freehand diamond or femtosecond laser-assisted penetrating and intrastromal arcuate incisions. Freehand diamond blade, corneal arcuate incisions (180° apart, 60° arc lengths) and 150 kHz femtosecond laser (80% scheimpflug pachymetry depth corneal thickness) arcuate incisions were performed in rabbits. Intrastromal arcuate incisions (100 μm above Descemet's membrane, 100 μm below epithelium) were performed in rabbit corneas (energy 1.2 μJ, spot line separation 3 × 3 μm, 90° side cut angle). Eyes were examined by slit lamp and light microscopy up to 47 days post-procedure. Freehand diamond blade penetrating incisions, and femtosecond laser penetrating and intrastromal arcuate incisions (energy 1.8 μJ, spot line separation 2 × 2 μm) were performed in cadaver eyes. Optical coherence tomography was performed immediately after surgery and the corneas were fixed for light scanning and transmission electron microscopy. The rabbit model showed anterior stromal inflammation with epithelial hyperplasia in penetrating blade and laser penetrating wounds. The laser intrastromal and penetrating incisions showed localized constriction of the stromal layers of the cornea near the wound. In cadaver eyes, penetrating wound morphology was similar between blade and laser whereas intrastromal wounds did not affect the cornea above or below incisions. Penetrating femtosecond laser arcuate incisions have more predictable and controlled outcomes shown by less post-operative scarring than incisions performed with a diamond blade. Intrastromal incisions do not affect uncut corneal layers as demonstrated by histopathology. The femtosecond laser has significant advantages in its ability to make intrastromal incisions which are not achievable by traditional freehand or mechanical diamond blades.

  8. Formulation and Evaluation of Exotic Fat Based Cosmeceuticals for Skin Repair

    OpenAIRE

    Mandawgade, S. D.; Patravale, Vandana B.

    2008-01-01

    Mango butter was explored as a functional, natural supplement and active skin ingredient in skin care formulations. A foot care cream was developed with mango butter to evaluate its medicinal value and protective function in skin repair. Qualitative comparison and clinical case studies of the product were carried out. Wound healing potential of foot care cream was investigated on the rat excision and incision wound models. Results of the clinical studies demonstrated complete repair of worn a...

  9. Influence of Incision Location on Transmitter Loss, Healing, Incision Lengths, Suture Retention, and Growth of Juvenile Chinook Salmon

    Energy Technology Data Exchange (ETDEWEB)

    Panther, Jennifer L.; Brown, Richard S.; Gaulke, Greggory L.; Woodley, Christa M.; Deters, Katherine A.

    2010-05-11

    In this study, conducted by Pacific Northwest National Laboratory for the U.S. Army Corps of Engineers, Portland District, we measured differences in survival and growth, incision openness, transmitter loss, wound healing, and erythema among abdominal incisions on the linea alba, lateral and parallel to the linea alba (muscle-cutting), and following the underlying muscle fibers (muscle-sparing). A total of 936 juvenile Chinook salmon were implanted with both Juvenile Salmon Acoustic Tracking System transmitters (0.43 g dry) and passive integrated transponder tags. Fish were held at 12°C (n = 468) or 20°C (n = 468) and examined once weekly over 98 days. We found survival and growth did not differ among incision groups or between temperature treatment groups. Incisions on the linea alba had less openness than muscle-cutting and muscle-sparing incisions during the first 14 days when fish were held at 12°C or 20°C. Transmitter loss was not different among incision locations by day 28 when fish were held at 12°C or 20°C. However, incisions on the linea alba had greater transmitter loss than muscle-cutting and muscle-sparing incisions by day 98 at 12°C. Results for wound closure and erythema differed among temperature groups. Results from our study will be used to improve fish-tagging procedures for future studies using acoustic or radio transmitters.

  10. An analysis of the repair processes in ultraviolet-irradiated Micrococcus luteus using purified ultraviolet-endonuclease

    International Nuclear Information System (INIS)

    Tomilin, N.V.; Zherebtsov, S.V.

    1982-01-01

    The measurement of the frequency of endonucleolytic incisions in ultraviolet-irradiated DNA serves as the test for the presence of pyrimidine dimers. In accordance with this approach, the lysates of three Micrococcus luteus strains containing radioactively labeled chromosomes were treated with purified M. luteus ultraviolet-endonuclease to trace segregation of dimers amongst parental and newly synthesized DNA and their removal during postreplication and excision DNA repair. A considerable proportion of the dimers in all strains tested proved to be insensitive to the action of exogenous incising enzyme. The use of chloramphenicol as an inhibitor of postirradiation protein synthesis in combination with ultraviolet-endonuclease treatment of DNA allowed to reveal at least two alternative pathways of postreplication repair: constitutively active recombinational pathway and inducible nonrecombinational one. (Auth.)

  11. T-Fix endoscopic meniscal repair: technique and approach to different types of tears.

    Science.gov (United States)

    Barrett, G R; Richardson, K; Koenig, V

    1995-04-01

    Endoscopic meniscus repair using the T-Fix suture device (Acufex Microsurgical, Inc, Mansfield, MA) allows ease of suture placement for meniscus stability without the problems associated with ancillary incisions such as neurovascular compromise. It is ideal for the central posterior horn tears that are difficult using conventional techniques. Vertical tears, bucket handle tears, flap tears, and horizontal tears can be approached using a temporary "anchor stitch" to stabilize the meniscus before T-Fix repair. The basic method of repair and our approach to these different types of tears is presented.

  12. The formation of double-strand breaks at multiply damaged sites is driven by the kinetics of excision/incision at base damage in eukaryotic cells

    International Nuclear Information System (INIS)

    Kozmin, S.G.; Sedletska, Y.; Reynaud-Angelin, A.; Sage, E.; Kozmin, S.G.; Sedletska, Y.; Reynaud-Angelin, A.; Sage, E.; Gasparutto, D.

    2009-01-01

    It has been stipulated that repair of clustered DNA lesions may be compromised, possibly leading to the formation of double-strand breaks (DSB) and, thus, to deleterious events. Using a variety of model multiply damaged sites (MDS), we investigated parameters that govern the formation of DSB during the processing of MDS. Duplexes carrying MDS were inserted into replicative or integrative vectors, and used to transform yeast Saccharomyces cerevisiae. Formation of DSB was assessed by a relevant plasmid survival assay. Kinetics of excision/incision and DSB formation at MDS was explored using yeast cell extracts. We show that MDS composed of two uracils or abasic sites, were rapidly incised and readily converted into DSB in yeast cells. In marked contrast, none of the MDS carrying opposed oG and hU separated by 38 bp gave rise to DSB, despite the fact that some of them contained preexisting single-strand break (a 1-nt gap). Interestingly, the absence of DSB formation in this case correlated with slow excision/incision rates of lesions. We propose that the kinetics of the initial repair steps at MDS is a major parameter that direct towards the conversion of MDS into DSB. Data provides clues to the biological consequences of MDS in eukaryotic cells. (authors)

  13. Recruitment and positioning determine the specific role of the XPF-ERCC1 endonuclease in interstrand crosslink repair.

    Science.gov (United States)

    Klein Douwel, Daisy; Hoogenboom, Wouter S; Boonen, Rick Acm; Knipscheer, Puck

    2017-07-14

    XPF-ERCC1 is a structure-specific endonuclease pivotal for several DNA repair pathways and, when mutated, can cause multiple diseases. Although the disease-specific mutations are thought to affect different DNA repair pathways, the molecular basis for this is unknown. Here we examine the function of XPF-ERCC1 in DNA interstrand crosslink (ICL) repair. We used Xenopus egg extracts to measure both ICL and nucleotide excision repair, and we identified mutations that are specifically defective in ICL repair. One of these separation-of-function mutations resides in the helicase-like domain of XPF and disrupts binding to SLX4 and recruitment to the ICL A small deletion in the same domain supports recruitment of XPF to the ICL, but inhibited the unhooking incisions most likely by disrupting a second, transient interaction with SLX4. Finally, mutation of residues in the nuclease domain did not affect localization of XPF-ERCC1 to the ICL but did prevent incisions on the ICL substrate. Our data support a model in which the ICL repair-specific function of XPF-ERCC1 is dependent on recruitment, positioning and substrate recognition. © 2017 The Authors. Published under the terms of the CC BY 4.0 license.

  14. On children's dyslexia with NIRS

    Science.gov (United States)

    Gan, Zhuo; Li, Chengjun; Gong, Hui; Luo, Qingming; Yao, Bin; Song, Ranran; Wu, Hanrong

    2003-12-01

    Developmental dyslexia is a kind of prevalent psychologic disease. Some functional imaging technologies, such as FMRI and PET, have been used to study the brain activities of dyslexics. NIRS is a kind of novel technology which is more and more widely being used for study of the cognitive psychology. However, there aren"t reports about the dyslexic research using NIRS to be found until now. This paper introduces a NIRS system of four measuring channels. Brain activities of dyslexic subjects and normal subjects during reading task were studied with the NIRS system. Two groups of subjects, the group of dyslexia and the group of normal, were appointed to perform two reading tasks. At the same time, their cortical activities were measured with the NIRS system. This experimental result indicates that the brain activities of the dyslexic group were significantly higher than the control group in BA 48 and that NIRS can be used for the study of human brain activity.

  15. Current Status of Single-incision Laparoscopic Surgery

    DEFF Research Database (Denmark)

    Ahmed, Irfan; Ciancio, Fabio; Ferrara, Vincenzo

    2012-01-01

    Recent advances in minimally invasive surgery have centered on reducing the number of incisions required, which has led to the development of the single-incision laparoscopic technique. A panel of European single-incision laparoscopy experts met to discuss the current status of, and the future...

  16. Electrocautery skin incision for neurosurgery procedures--technical note.

    Science.gov (United States)

    Nitta, Naoki; Fukami, Tadateru; Nozaki, Kazuhiko

    2011-01-01

    The reluctance to incise skin with electrocautery is partly attributable to concerns about excessive scarring and poor wound healing. However, recently no difference was reported in wound complications between the cold scalpel and electrocautery scalpel. We assessed the safety and efficacy of electrocautery skin incision in 22 scalp incisions, including 4 cases of reoperation. Electrocautery skin incisions were created using a sharp needle electrode. The generator unit was set on cutting mode, with power of 6 W and 330 kHz sinusoid waveform. Subcutaneous dissections also used the sharp needle electrode, set on coagulating mode, with power of 10 W and 1 MHz pulse-modulated waveform. Galea incisions used a standard blade tip, set on coagulating mode, with power of 20 W and 1 MHz pulse-modulated waveform. Skin incision with the sharp needle electrode caused no charring of the wound. Little bleeding or oozing were observed and skin clips were not necessary. No wound complication such as necrosis or infection occurred. Electrocautery skin incisions for re-operations were also performed safely without complications. Electrocautery skin incision is sufficiently safe procedure not only for first operation but also for re-operation. Electrocautery skin incision is efficacious, especially for extended operation times, because of little blood loss from the edges of skin incision and possible avoidance of skin edge necrosis or alopecia caused by skin clips.

  17. Comparison of the Keratometric Corneal Astigmatic Power after Phacoemulsification: Clear Temporal Corneal Incision versus Superior Scleral Tunnel Incision

    Directory of Open Access Journals (Sweden)

    Yongqi He

    2009-01-01

    Full Text Available Objective. This is prospective randomized control trial to compare the mean keratometric corneal astigmatism diopter power (not surgical induced astigmatism among preop and one-month and three-month postop phacoemulcification of either a clear temporal corneal incision or a superior scleral tunnel Incision, using only keratometric astigmatic power reading to evaluate the difference between the two cataract surgery incisions. Methods. 120 patients (134 eyes underwent phacoemulcification were randomly assigned to two groups: Group A, the clear temporal corneal incision group, and Group B, the superior scleral tunnel incision group. SPSS11.5 Software was used for statistical analysis to compare the postsurgical changes of cornea astigmatism on keratometry. Results. The changes of corneal astigmatic diopter in Groups A and B after 3 month postop from keratometric reading were 1.04 + 0.76 and 0.94 + 0.27, respectively (=.84>.05, which showed no statistic significance difference. Conclusion. The incision through either temporal clear cornea or superior scleral tunnel in phacoemulcification shows no statistic difference in astigmatism change on keratometry 3-month postop.

  18. Inhibition of DNA repair by trifluoperazine

    Energy Technology Data Exchange (ETDEWEB)

    Charp, P.A.; Regan, J.D.

    1985-01-01

    The authors examined the possible role of calmodulin in the excision repair of ultraviolet light-induced pyrimidine dimers in damaged DNA by means of specialized assay systems. These assays included bromodeoxyuridine photolysis, dimer chromatography and cytosine arabinoside incorporation in conjunction with hydroxyurea. The calmodulin antagonist, trifluoperazine, and the calcium-chelating agent, EGTA, were employed to ascertain what affect calmodulin played in the repair process. Normal human fibroblast cells are used in all studies described in this report. After exposure to 10 J/m2 of 254 nm light, the authors observed a decrease of about 30% in the number of single-strand breaks produced in the presence of 25 M trifluoperazine (1.9 vs. 3.3) in controls although the numbers of bases re-inserted in the repaired regions were similar (64 vs. 72). Measurement of thymine-containing dimers remaining throughout a 24 h time period indicated a 30% difference decrease in the number of cytosine arabinoside arrested repair sites in the presence of either EGTA or trifluoperazine. The results are discussed with relation to the possibility of calmodulin altering the initial incision by repair endonuclease. 27 references, 3 figures.

  19. Single scrotal incision orchiopexy - a systematic review

    Directory of Open Access Journals (Sweden)

    Hugo Fabiano Fernandes Novaes

    2013-06-01

    Full Text Available Objective To conduct a systematic review on single scrotal incision orchiopexy. Materials and Methods A search was performed using Pubmed, through which 16 articles were selected out of a total of 133. The following conditions were considered exclusion criteria: other surgical methods such as an inguinal procedure or a laparoscopic approach, retractile testes, or patients with previous testicular or inguinal surgery. Results A total of 1558 orchiopexy surgeries initiated with a transcrotal incision were analyzed. Patients' ages ranged between 5 months and 21 years. Thirteen studies used high scrotal incisions, and low scrotal incisions were performed in the remainder of the studies. In 55 cases (3.53%, there was a need for inguinal incision. Recurrence was observed in 9 cases, testicular atrophy in 3, testicular hypotrophy in 2, and surgical site infections in 13 cases. High efficacy rates were observed, varying between 88% and 100%. Conclusions Single scrotal incision orchiopexy proved to be an effective technique and is associated with low rates of complications.

  20. Flexible single-incision surgery: a fusion technique.

    Science.gov (United States)

    Noguera, José F; Dolz, Carlos; Cuadrado, Angel; Olea, José; García, Juan

    2013-06-01

    The development of natural orifice transluminal endoscopic surgery has led to other techniques, such as single-incision surgery. The use of the flexible endoscope for single-incision surgery paves the way for further refinement of both surgical methods. To describe a new, single-incision surgical technique, namely, flexible single-incision surgery. Assessment of the safety and effectiveness of endoscopic cholecystectomy in a series of 30 patients. This technique consists of a single umbilical incision through which a flexible endoscope is introduced and consists of 2 parallel entry ports that provide access to nonarticulated laparoscopic instruments. The technique was applied in all patients for whom it was prescribed. No general or surgical wound complications were noted. Surgical time was no longer than usual for single-port surgery. Flexible single-incision surgery is a new single-site surgical technique offering the same level of patient safety, with additional advantages for the surgeon at minimal cost.

  1. Proteomics reveals dynamic assembly of repair complexes during bypass of DNA cross-links

    DEFF Research Database (Denmark)

    Räschle, Markus; Smeenk, Godelieve; Hansen, Rebecca K

    2015-01-01

    DNA interstrand cross-links (ICLs) block replication fork progression by inhibiting DNA strand separation. Repair of ICLs requires sequential incisions, translesion DNA synthesis, and homologous recombination, but the full set of factors involved in these transactions remains unknown. We devised ...

  2. Repair of abasic sites in DNA

    Energy Technology Data Exchange (ETDEWEB)

    Dianov, Grigory L.; Sleeth, Kate M.; Dianova, Irina I.; Allinson, Sarah L

    2003-10-29

    Repair of both normal and reduced AP sites is activated by AP endonuclease, which recognizes and cleaves a phosphodiester bond 5' to the AP site. For a short period of time an incised AP site is occupied by poly(ADP-ribose) polymerase and then DNA polymerase {beta} adds one nucleotide into the repair gap and simultaneously removes the 5'-sugar phosphate. Finally, the DNA ligase III/XRCC1 complex accomplishes repair by sealing disrupted DNA ends. However, long-patch BER pathway, which is involved in the removal of reduced abasic sites, requires further DNA synthesis resulting in strand displacement and the generation of a damage-containing flap that is later removed by the flap endonuclease. Strand-displacement DNA synthesis is accomplished by DNA polymerase {delta}/{epsilon} and DNA ligase I restores DNA integrity. DNA synthesis by DNA polymerase {delta}/{epsilon} is dependent on proliferating cell nuclear antigen, which also stimulates the DNA ligase I and flap endonuclease. These repair events are supported by multiple protein-protein interactions.

  3. Repair of DNA damage in Deinococcus radiodurans

    International Nuclear Information System (INIS)

    Evans, D.M.

    1984-01-01

    The repair of DNA lesions in Deinococcus radiodurans was examined with particular reference to DNA excision repair of ultraviolet light (UV) induced pyrimidine dimers. The characteristics of excision repair via UV endonucleases α and β in vivo varied with respect to (a) the substrate range of the enzymes, (b) the rate of repair of DNA damage (c) the requirement for a protein synthesised in response to DNA damage to attenuate exonuclease action at repairing regions. UV endonuclease α is postulated to incise DNA in a different manner from UV endonuclease β thus defining the method of subsequent repair. Several DNA damage specific endonuclease activities independent of α and β are described. Mutations of the uvsA, uvsF and uvsG genes resulted in an increase in single-strand breaks in response to DNA damage producing uncontrolled DNA degradation. Evidence is presented that these genes have a role in limiting the access of UV endonuclease β to DNA lesions. uvsF and uvsG are also shown to be linked to the mtoA gene. Mutation of uvsH and reo-1 produces further distinct phenotypes which are discussed. An overall model of excision repair of DNA damage in Deinococcus radiodurans is presented. (author)

  4. Differential effects of procaine and phenethyl alcohol on excision repair of DNA in u.v.-irradiated Escherichia coli

    International Nuclear Information System (INIS)

    Tomiyama, H.; Tachibana, A.; Yonei, S.

    1986-01-01

    Experiments were performed to investigate the involvement of the cell membrane in the excision DNA repair process in Escherichia coli. Two membrane-binding drugs, procaine and phenethyl alcohol (PEA), inhibited liquid-holding recovery (LBR) in u.v.-irradiated E. coli wild-type and recA strains. In uvrB and polA strains where, after u.v.-irradiation, LHR was absent the two drugs had no effect. Both drugs markedly reduced the removal of u.v.-induced thymine dimers in the DNA of wild-type cells (H/r30). Analysis by alkaline sucrose gradients revealed that PEA inhibited the incision step in excision repair. In contrast, procaine had no effect on incision but apparently inhibited the late steps in excision repair. PEA dissociated DNA from the cell membrane, whereas procaine did not. The results suggest that the two drugs PEA and procaine inhibit LHR and the excision repair process operating on u.v.-induced damage in E. coli by at least two different mechanisms each of which may involve the cell membrane. (author)

  5. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  6. Laparoscopic repair of large suprapubic hernias.

    Science.gov (United States)

    Sikar, Hasan Ediz; Çetin, Kenan; Eyvaz, Kemal; Kaptanoglu, Levent; Küçük, Hasan Fehmi

    2017-09-01

    Suprapubic hernia is the term to describe ventral hernias located less than 4 cm above the pubic arch in the midline. Hernias with an upper margin above the arcuate line encounter technical difficulties, and the differences in repair methods forced us to define them as large suprapubic hernias. To present our experience with laparoscopic repair of large suprapubic hernias that allows adequate mesh overlap. Nineteen patients with suprapubic incisional hernias who underwent laparoscopic repair between May 2013 and January 2015 were included in the study. Patients with laparoscopic extraperitoneal repair who had a suprapubic hernia with an upper margin below the arcuate line were excluded. Two men and 17 women, with a mean age of 58.2, underwent laparoscopic repair. Most of the incisions were midline vertical (13/68.4%). Twelve (63.1%) of the patients had previous incisional hernia repair (PIHR group); the mean number of previous incisional hernia repair was 1.4. Mean defect size of the PIHR group was higher than in patients without previous repair - 107.3 cm 2 vs. 50.9 cm 2 (p < 0.05). Mean operating time of the PIHR group was higher than in patients without repair - 126 min vs. 77.9 min (p < 0.05). Although all complications occurred in the PIHR group, there was no statistically significant difference. Laparoscopic repair of large suprapubic hernias can be considered as the first option in treatment. The low recurrence rates reported in the literature and the lack of recurrence, as observed in our study, support this view.

  7. Characterization of a mutant rat kangaroo cell line with alterations in the cell cycle and DNA repair

    OpenAIRE

    Miyaji, E.N.; Johnson, R.T.; Downes, C.S.; Eveno, E.; Mezzina, M.; Sarasin, A.; Menck, C.F.M.

    2000-01-01

    Using a positive selection system for isolating DNA replication and repair related mutants, we isolated a clone from a rat kangaroo cell line (PtK2) that has increased sensitivity to UV light. Characterization of this clone indicated normal post-replication repair after UV irradiation, and normal removal rates of cyclobutane pyrimidine dimers and pyrimidine(6-4)pyrimidone photoproducts by excision repair. However, this cell line has decreased ability to make early incisions on damaged DNA, po...

  8. Regulation of nucleotide excision repair through ubiquitination

    Institute of Scientific and Technical Information of China (English)

    Jia Li; Audesh Bhat; Wei Xiao

    2011-01-01

    Nucleotide excision repair (NER) is the most versatile DNA-repair pathway in all organisms.While bacteria require only three proteins to complete the incision step of NER,eukaryotes employ about 30 proteins to complete the same step.Here we summarize recent studies demonstrating that ubiquitination,a post-translational modification,plays critical roles in regulating the NER activity either dependent on or independent of ubiquitin-proteolysis.Several NER components have been shown as targets of ubiquitination while others are actively involved in the ubiquitination process.We argue through this analysis that ubiquitination serves to coordinate various steps of NER and meanwhile connect NER with other related pathways to achieve the efficient global DNA-damage response.

  9. Cytochrome cd1-containing nitrite reductase encoding gene nirS as a new functional biomarker for detection of anaerobic ammonium oxidizing (Anammox) bacteria.

    Science.gov (United States)

    Li, Meng; Ford, Tim; Li, Xiaoyan; Gu, Ji-Dong

    2011-04-15

    A newly designed primer set (AnnirS), together with a previously published primer set (ScnirS), was used to detect anammox bacterial nirS genes from sediments collected from three marine environments. Phylogenetic analysis demonstrated that all retrieved sequences were clearly different from typical denitrifiers' nirS, but do group together with the known anammox bacterial nirS. Sequences targeted by ScnirS are closely related to Scalindua nirS genes recovered from the Peruvian oxygen minimum zone (OMZ), whereas sequences targeted by AnnirS are more closely affiliated with the nirS of Candidatus 'Kuenenia stuttgartiensis' and even form a new phylogenetic nirS clade, which might be related to other genera of the anammox bacteria. Analysis demonstrated that retrieved sequences had higher sequence identities (>60%) with known anammox bacterial nirS genes than with denitrifiers' nirS, on both nucleotide and amino acid levels. Compared to the 16S rRNA and hydrazine oxidoreductase (hzo) genes, the anammox bacterial nirS not only showed consistent phylogenetic relationships but also demonstrated more reliable quantification of anammox bacteria because of the single copy of the nirS gene in the anammox bacterial genome and the specificity of PCR primers for different genera of anammox bacteria, thus providing a suitable functional biomarker for investigation of anammox bacteria.

  10. A simple novel technique [PUIT] for closure of urethrocutaneous fistula after hypospadias repair: Preliminary results

    Directory of Open Access Journals (Sweden)

    Awad M

    2005-01-01

    Full Text Available Urethrocutaneous fistula is a common complication of urethroplasty for severe hypospadias, even when a microsurgical technique is applied, the closure of the fistula is a challenging problem. We present a simple surgical procedure, posterior urethral incision technique [PUIT] to close the fistula in our department. Between February 2001 and December 2004 we prospectively evaluated 32 patients, 26 patients with initial hypospadias fistulas and 6 with recurrent fistulas who underwent closure of urethrocutaneous fistula after hypospadias repair. The mean age of patients was 5 years, the operation consisted of trimming the fistula edge after mobilization of the skin all-around then a midline posterior urethral incision was done 2 mm above and 2 mm below the fistula opening then re-approximation of the urethral edges using 6/0 vicryl sutures with loop magnification. The timing of fistula repair was between 6 and 13 months after it was formed, all of these were effectively closed except three cases with stricture and fistula. Of these, two were completely relieved after repeated urethral dilatation, three times a week for 2 weeks. The third failed case will need another sitting after 6 months. The posterior midline urethral incision gives a good opportunity for repair without tension with a good cosmetic outcome. This may be done under local anesthesia in adults. The procedure is considered simple rapid and easy to be done for variable fistulas types whatever of its site and the age.

  11. Microbeam facility at NIRS

    International Nuclear Information System (INIS)

    Sato, Yukio; Yamaguchi, Hiroshi

    2000-01-01

    Radiation biophysics or microdosimetry has suggested radiation effect mechanism. Full understanding of it has not yet been obtained. There are vast variety of events in physical, chemical and biological processes from at the time of irradiation to biological endpoints. Analysis of RBE-LET relation for biological endpoints like survival, mutation and transformation in cultured mammalian cells is still the leading subject to study the physical processes. The biological and repair processes have been studied phenomenologically through dose rate effect or fractionation experiment. Human genome project has accelerated biological sciences as a whole taking methodology of the molecular biology, where the mechanism is explained by molecules involved. We have thus to know entity and its (biological) function in every single process. Molecular biological approach in radiation biology has started and revealed several proteins being involved in the repair processes. Quantitative relation between phenomenological data like cell survivals and molecular processes, however, has been little known yet. A promising approach to fill this gap should be the study by microbeam, which enables us to see, for example, a deletion in chromosomal level by a single particle traverse of cell nucleus and may suggest possible molecular processes. Under this motivation we started feasibility study on installation of a microbeam port in our Tandem accelerator (5.1 MeV 4 He 2+ ). We have planned to adopt a lens focusing and a scanning system developed (by the Oxford microbeam Ltd) for the existing micro PIXE system in NIRS, which has basically achieved irradiation to a cell within a position resolution of 2 micrometer. There are two practical requirements, i.e. precise positioning and faster irradiation. These are described including research subjects planned. (author)

  12. Gamma-ray induced inhibition of DNA synthesis in ataxia telangiectasia fibroblasts is a function of excision repair capacity

    International Nuclear Information System (INIS)

    Smith, P.J.; Paterson, M.C.

    1980-01-01

    The extent of the deficiency in γ-ray induced DNA repair synthesis in an ataxia telangiectasia (AT) human fibroblast strain was found to show no oxygen enhancement, consistent with a defect in the repair of base damage. Repair deficiency, but not repair proficiency, in AT cells was accompanied by a lack of inhibition of DNA synthesis by either γ-rays or the radiomimetic drug bleomycin. Experiments with 4-nitroquinoline 1-oxide indicated that lack of inhibition was specific for radiogenic-type damage. Thus excision repair, perhaps by DNA strand incision or chromatin modification, appears to halt replicon initiation in irradiated repair proficient cells whereas in repair defective AT strains this putatively important biological function is inoperative

  13. Vertical compared with transverse incisions in abdominal surgery

    DEFF Research Database (Denmark)

    Grantcharov, T P; Rosenberg, J

    2001-01-01

    , and late complications (incisional hernia). RESULTS: Eleven randomised controlled trials and seven retrospective studies were identified. The transverse incision offers as good an access to most intra-abdominal structures as a vertical incision. The transverse incision results in significantly less......OBJECTIVE: To reach an evidence-based consensus on the relative merits of vertical and transverse laparotomy incisions. DESIGN: Review of all published randomised controlled trials that compared the postoperative complications after the two main types of abdominal incisions, vertical and transverse....... SETTING: Teaching hospital, Denmark. SUBJECTS: Patients undergoing open abdominal operations. INTERVENTIONS: For some of the variables (burst abdomen and incisional hernia) it was considered adequate to include retrospective studies. Studies were identified through Medline, Cochrane library, Embase...

  14. Two-Step Incision for Periarterial Sympathectomy of the Hand

    Directory of Open Access Journals (Sweden)

    Seung Bae Jeon

    2015-11-01

    Full Text Available BackgroundSurgical scars on the palmar surface of the hand may lead to functional and also aesthetic and psychological consequences. The objective of this study was to introduce a new incision technique for periarterial sympathectomy of the hand and to compare the results of the new two-step incision technique with those of a Koman incision by using an objective questionnaire.MethodsA total of 40 patients (17 men and 23 women with intractable Raynaud's disease or syndrome underwent surgery in our hospital, conducted by a single surgeon, between January 2008 and January 2013. Patients who had undergone extended sympathectomy or vessel graft were excluded. Clinical evaluation of postoperative scars was performed in both groups one year after surgery using the patient and observer scar assessment scale (POSAS and the Wake Forest University rating scale.ResultsThe total patient score was 8.59 (range, 6-15 in the two-step incision group and 9.62 (range, 7-18 in the Koman incision group. A significant difference was found between the groups in the total PS score (P-value=0.034 but not in the total observer score. Our analysis found no significant difference in preoperative and postoperative Wake Forest University rating scale scores between the two-step and Koman incision groups. The time required for recovery prior to returning to work after surgery was shorter in the two-step incision group, with a mean of 29.48 days in the two-step incision group and 34.15 days in the Koman incision group (P=0.03.ConclusionsCompared to the Koman incision, the new two-step incision technique provides better aesthetic results, similar symptom improvement, and a reduction in the recovery time required before returning to work. Furthermore, this incision allows the surgeon to access a wide surgical field and a sufficient exposure of anatomical structures.

  15. Liquid in the major incision

    International Nuclear Information System (INIS)

    Herrera Jaramillo, Diego Alberto; Ortega Jaramillo, Hector

    2003-01-01

    We present the case of a patient with spill pleural extending in the left major incision. In the chest thorax PA, we could observe one of the complex radiographic appearances that take the reconfiguration of fluid in this localization, being this appearance dependent of the patient's position. Some points are also discussed on the anatomy of the major incisions and some of their radiographic characteristics

  16. The longitudinal epineural incision and complete nerve transection method for modeling sciatic nerve injury

    Directory of Open Access Journals (Sweden)

    Xing-long Cheng

    2015-01-01

    Full Text Available Injury severity, operative technique and nerve regeneration are important factors to consider when constructing a model of peripheral nerve injury. Here, we present a novel peripheral nerve injury model and compare it with the complete sciatic nerve transection method. In the experimental group, under a microscope, a 3-mm longitudinal incision was made in the epineurium of the sciatic nerve to reveal the nerve fibers, which were then transected. The small, longitudinal incision in the epineurium was then sutured closed, requiring no stump anastomosis. In the control group, the sciatic nerve was completely transected, and the epineurium was repaired by anastomosis. At 2 and 4 weeks after surgery, Wallerian degeneration was observed in both groups. In the experimental group, at 8 and 12 weeks after surgery, distinct medullary nerve fibers and axons were observed in the injured sciatic nerve. Regular, dense myelin sheaths were visible, as well as some scarring. By 12 weeks, the myelin sheaths were normal and intact, and a tight lamellar structure was observed. Functionally, limb movement and nerve conduction recovered in the injured region between 4 and 12 weeks. The present results demonstrate that longitudinal epineural incision with nerve transection can stably replicate a model of Sunderland grade IV peripheral nerve injury. Compared with the complete sciatic nerve transection model, our method reduced the difficulties of micromanipulation and surgery time, and resulted in good stump restoration, nerve regeneration, and functional recovery.

  17. Urinary function after Snodgrass repair of distal hypospadias: comparison with the Mathieu repair.

    Science.gov (United States)

    Scarpa, Maria Grazia; Castagnetti, Marco; Berrettini, Alfredo; Rigamonti, Waifro; Musi, Luciano

    2010-05-01

    To evaluate urinary function in patients with distal hypospadias undergoing repair by the tubularized incised-plate urethroplasty (TIP or Snodgrass), compare the results with those in patients treated by the Mathieu technique, and show the potential issues inherent to the evaluation of such results. A cross-sectional assessment was performed of uncomplicated distal hypospadias operated on during a 3-year period, already toilet trained, and able to void volitionally. Evaluation included clinical assessment urinary symptoms and urinary stream, and uroflowmetry. Out of 83 patients operated on during the study period, 10 (12%) developed complication and 32 were not toilet trained or refused to participate in the study. Median follow-up in the remaining 41 patients included in the study was 20 (3-36) months. None of these patients presented voiding symptoms or urinary stream abnormalities. Uroflowmetry was normal in 30 cases and obstructive in 11 (27%). An obstructive flow pattern was more common in patients undergoing TIP versus Mathieu repair, 8 of 19 (42%) versus 3 of 22 (14%), respectively (P = 0.07). Four TIP cases with an obstructive uroflow pattern were managed conservatively. Although both the TIP and the Mathieu repair allow good results in terms of urinary function after distal hypospadias repairs, the TIP technique seems more likely to be associated with urine flow pattern abnormalities. The actual clinical relevance of this finding remains ill defined.

  18. DNA Methylation Modulates Nociceptive Sensitization after Incision.

    Directory of Open Access Journals (Sweden)

    Yuan Sun

    Full Text Available DNA methylation is a key epigenetic mechanism controlling DNA accessibility and gene expression. Blockade of DNA methylation can significantly affect pain behaviors implicated in neuropathic and inflammatory pain. However, the role of DNA methylation with regard to postoperative pain has not yet been explored. In this study we sought to investigate the role of DNA methylation in modulating incisional pain and identify possible targets under DNA methylation and contributing to incisional pain. DNA methyltranferase (DNMT inhibitor 5-Aza-2'-deoxycytidine significantly reduced incision-induced mechanical allodynia and thermal sensitivity. Aza-2'-deoxycytidine also reduced hindpaw swelling after incision, suggesting an anti-inflammatory effect. Global DNA methylation and DNMT3b expression were increased in skin after incision, but none of DNMT1, DNMT3a or DNMT3b was altered in spinal cord or DRG. The expression of proopiomelanocortin Pomc encoding β-endorphin and Oprm1 encoding the mu-opioid receptor were upregulated peripherally after incision; moreover, Oprm1 expression was further increased under DNMT inhibitor treatment. Finally, local peripheral injection of the opioid receptor antagonist naloxone significantly exacerbated incision-induced mechanical hypersensitivity. These results suggest that DNA methylation is functionally relevant to incisional nociceptive sensitization, and that mu-opioid receptor signaling might be one methylation regulated pathway controlling sensitization after incision.

  19. Association between age and repair of oxidatively damaged DNA in human peripheral blood mononuclear cells

    DEFF Research Database (Denmark)

    Løhr, Mille; Jensen, Annie; Eriksen, Louise

    2015-01-01

    damaged DNA in peripheral blood mononuclear cells (PBMCs). We isolated PBMCs from subjects aged 18-83 years, as part of a health survey of the Danish population that focussed on lifestyle factors. The level of DNA repair activity was measured as incisions on potassium bromate-damaged DNA by the comet...... assay. There was an inverse association between age and DNA repair activity with a 0.65% decline in activity per year from age 18 to 83 (95% confidence interval: 0.16-1.14% per year). Univariate regression analysis also indicated inverse associations between DNA repair activity and waist-hip ratio (P...

  20. Morphodynamic Model of Submarine Canyon Incision by Sandblasting

    Science.gov (United States)

    Zhang, L.; Parker, G.; Izumi, N.; Cartigny, M.; Li, T.; Wang, G.

    2017-12-01

    Submarine canyons are carved by turbidity currents under the deep sea. As opposed to subaerial canyons, the relevant processes are not easy to observe directly. Turbidity currents are bottom-hugging sediment gravity flows of that can incise or deposit on the seafloor to create submarine canyons or fans. The triggers of turbidity currents can be storms, edge waves, internal waves, canyon wall sapping, delta failure, breaching and hyperpycnal flows. The formation and evolution mechanisms of submarine canyons are similar to those of subaerial canyons, but have substantial differences. For example, sandblasting, rather than wear due to colliding gravel clasts is more likely to be the mechanism of bedrock incision. Submarine canyons incise downward, and often develop meander bends and levees within the canyon, so defining "fairways". Here we propose a simple model for canyon incision. The starting point of our model is the Macro Roughness Saltation Abrasion Alluviation model of Zhang et al. [2015], designed for bedrock incision by gravel clasts in mixed bedrock-alluvial rivers. We adapt this formulation to consider sandblasting as a means of wear. We use a layer-averaged model for turbidity current dynamics. The current contains a mixture of mud, which helps drive the flow but which does not cause incision, and sand, which is the agent of incision. We show that the model can successfully model channel downcutting, and indeed illustrate the early formation of net incisional cyclic steps, i.e. upstream-migrating undulations on the bed associated with transcritical (in the Froude sense) flow. These steps can be expected to abet the process of incision.

  1. NIRS in Space?

    Science.gov (United States)

    Peterson, David L.; Condon, Estelle (Technical Monitor)

    2000-01-01

    Proponents of near infrared reflectance spectroscopy (NIRS) have been exceptionally successful in applying NIRS techniques to many instances of organic material analyses. While this research and development began in the 1950s, in recent years, stimulation of advancements in instrumentation is allowing NIRS to begin to find its way into the food processing systems, into food quality and safety, textiles and much more. And, imaging high spectral resolution spectrometers are now being evaluated for the rapid scanning of foodstuffs, such as the inspection of whole chicken carcasses for fecal contamination. The imaging methods are also finding their way into medical applications, such as the non-intrusive monitoring of blood oxygenation in newborns. Can these scientific insights also be taken into space and successfully used to measure the Earth's condition? Is there an analog between the organic analyses in the laboratory and clinical settings and the study of Earth's living biosphere? How are the methods comparable and how do they differ?

  2. Recognition and repair of the CC-1065-(N3-Adenine)-DNA adduct by the UVRABC nuclease

    International Nuclear Information System (INIS)

    Tang, M.; Lee, C.S.; Doisy, R.; Ross, L.; Needham-VanDevanter, D.R.; Hurley, L.H.

    1988-01-01

    The recognition and repair of the helix-stabilizing and relatively nondistortive CC-1065-(N3-adenine)-DNA adduct by UVRABC nuclease has been investigated both in vivo with phi X174RFI DNA by a transfection assay and in vitro by a site-directed adduct in a 117 base pair fragment from M13mp1. CC-1065 is a potent antitumor antibiotic produced by Streptomyces zelensis which binds within the minor groove of DNA through N3 of adenine. In contrast to the helix-destabilizing and distortive modifications of DNA caused by ultraviolet light or N-acetoxy-2-(acetylamino)fluorene, CC-1065 increases the melting point of DNA and decreases the S1 nuclease activity. Using a viral DNA-Escherichia coli transfection system, the authors have found that the uvrA, uvrB, and uvrC genes, which code for the major excision repair proteins for UV- and NAAAF-induced DNA damage, are also involved in the repair of CC-1065-DNA adducts. In contrast, the uvrD gene product, which has been found to be involved in the repair of UV damage, has no effect in repairing CC-1065-DNA adducts. Purified UVRA, UVRB, and UVRC proteins must work in concert to incise the drug-modified phi X174RFI DNA. Using a site-directed and multiple CC-1065 modified (MspI-BstNI) 117 base pair fragment from M13mp1, they have found that UVRABC nuclease incises at the eight phosphodiester bond on the 5' side of the CC-1065-DNA adduct on the drug-modified strand. The enzymes do not cut the noncovalently modified strand. The DNA sequence and/or helix-stabilizing effect of multiple adducts may determine the recognition and/or incision of the drug-DNA adduct by UVRABC nuclease. These results are discussed in relation to the structure of the CC-1065-DNA adduct and the effect of drug binding on local DNA structure

  3. Primary closure of equine laryngotomy incisions

    DEFF Research Database (Denmark)

    Lindegaard, C.; Karlsson, L.; Ekstrøm, Claus Thorn

    2016-01-01

    incision between January 1995 and June 2012 were reviewed. Horses with a laryngotomy incision closed in three layers for primary healing were included. Descriptive data on healing characteristics and complications of laryngotomy wounds were collected from the medical records and via follow......The objective was to report healing characteristics and complications after primary closure of equine laryngotomies and analyse factors potentially associated with complications. This retrospective case series of the medical records of horses (n = 180) undergoing laryngoplasty and laryngotomy...... after primary closure of equine laryngotomy incisions are infrequent and considered of minimal severity and can be performed safely when paying careful attention to the closure of the cricothyroid membrane....

  4. Laser-activated nano-biomaterials for tissue repair and controlled drug release

    International Nuclear Information System (INIS)

    Matteini, P; Ratto, F; Rossi, F; Pini, R

    2014-01-01

    We present recent achievements of minimally invasive welding of biological tissue and controlled drug release based on laser-activated nano-biomaterials. In particular, we consider new advancements in the biomedical application of near-IR absorbing gold nano-chromophores as an original solution for the photothermal repair of surgical incisions and as nanotriggers of controlled drug release from hybrid biopolymer scaffolds. (laser biophotonics)

  5. Incomplete excision repair process after UV-irradiation in MUT-mutants of Proteus mirabillis

    International Nuclear Information System (INIS)

    Stoerl, K.

    1977-01-01

    MUT-mutants of P. mirabilis seem to be able to perform the incision step in the course of excision repair. In contrast to the corresponding wildtype strains with MUT-mutants the number of single-strand breaks formed after UV-irradiation is independent of the UV-dose up to about 720 erg/mm 2 . Incubation in minimal medium over a longer time does not result in completion of excision repair; about 3-6 single-strand breaks in the DNA of these mutants remain open. Likewise, the low molecular weight of the newly synthesized daughter DNA confirms an incompletely proceeding or delayed repair process. As a possible reason for the mutator phenotype an alteration of the DNA-polymerase playing a role in excision and resynthesis steps of excision repair is discussed. (author)

  6. Mini transverse versus longitudinal incision in carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Korkmaz, M.; Cepoglu, M.C.

    2013-01-01

    Objective: To evaluate the effectiveness of mini-transverse compared with mini-longitudinal incision for carpal tunnel release (CTR) with reference to postoperative functional capacity, symptom severity and complication rate. Study Design: Analytical study. Place and Duration of Study: Cumhuriyet University Medical Faculty, Department of Orthopaedics, Tokat State Hospital, Department of Orthopaedics and Medical Park Tokat Hospital, Department of Neurosurgery, from January 2007 to January 2009. Methodology: This study included 93 hands of 79 patients with carpal tunnel syndrome (CTS), which were operated between 2007 and 2009. Patients were divided according to incision types into Group-1 (undergoing mini-longitudinal incision) and Group-2 (undergoing mini-transverse incision). Patients were evaluated initially and at 3 weeks after treatment according to symptom severity and functional status of Boston Questionnaire (BQ). Demographic and clinical data were analyzed and compared statistically between two groups. Results: Statistically significant differences were observed in BQ symptom and functional scores between the pre- and postoperative period (p < 0.0001). BQ symptom and functional scores at postoperative period were better in Group-1 than Group-2 (p = 0.044 and p = 0.023 respectively). The scar hypersensitivity (p = 0.258) and tenderness (p = 1.00) associated with the incision sites were not statistically different. Conclusion: Longitudinal incision is more effective on symptom and functional conditions than transverse incision. However, there was less scar formation with transverse incision. (author)

  7. The current state of eukaryotic DNA base damage and repair.

    Science.gov (United States)

    Bauer, Nicholas C; Corbett, Anita H; Doetsch, Paul W

    2015-12-02

    DNA damage is a natural hazard of life. The most common DNA lesions are base, sugar, and single-strand break damage resulting from oxidation, alkylation, deamination, and spontaneous hydrolysis. If left unrepaired, such lesions can become fixed in the genome as permanent mutations. Thus, evolution has led to the creation of several highly conserved, partially redundant pathways to repair or mitigate the effects of DNA base damage. The biochemical mechanisms of these pathways have been well characterized and the impact of this work was recently highlighted by the selection of Tomas Lindahl, Aziz Sancar and Paul Modrich as the recipients of the 2015 Nobel Prize in Chemistry for their seminal work in defining DNA repair pathways. However, how these repair pathways are regulated and interconnected is still being elucidated. This review focuses on the classical base excision repair and strand incision pathways in eukaryotes, considering both Saccharomyces cerevisiae and humans, and extends to some important questions and challenges facing the field of DNA base damage repair. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  8. Greenhouse cooling by NIR-reflection

    NARCIS (Netherlands)

    Hemming, S.; Kempkes, F.; Braak, van der N.; Dueck, T.A.; Marissen, A.

    2007-01-01

    Wageningen UR investigated the potential of several NIR-filtering methods to be applied in horticulture. In this paper the analysis of the optical properties of available NIR-filtering materials is given including a calculation method to quantify the energy reduction under these materials and to

  9. Single Incision Laparoscopic Splenectomy: Our First Experiences

    Directory of Open Access Journals (Sweden)

    Umut Barbaros

    2011-06-01

    Full Text Available Objective: Most laparoscopic surgeons have attempted to reduce incisional morbidity and improve cosmetic outcomes by using less and smaller trocars. Single incision laparoscopic splenectomy is a new laparoscopic procedure. Herein we would like to present our experiences.Material and Methods: Between January 2009 and June 2009, data of the 7 patients who underwent single incision laparoscopic splenectomy were evaluated retrospectively.Results: There were 7 patients (5 females and 2 males with a mean age of 29.9 years. The most common splenectomy indication was idiopathic thrombocytopenic purpura. Single incision laparoscopic splenectomy was performed successfully in 6 patients. In one patient the operation was converted to an open procedure.Conclusion: With surgeons experienced in minimally invasive surgery, single incision laparoscopic splenectomy could be performed successfully. However, in order to demonstrate the differneces between standard laparoscopic splenectomy and SILS splenetomy, prospective randomized comparative studies are required.

  10. Dual mode NIR long persistent phosphorescence and NIR-to-NIR Stokes luminescence in La{sub 3}Ga{sub 5}GeO{sub 14}: Cr{sup 3+}, Nd{sup 3+} phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Yiling; Li, Yang, E-mail: msliyang@scut.edu.cn; Qin, Xixi; Chen, Ruchun; Wu, Dakun; Liu, Shijian; Qiu, Jianrong, E-mail: qjr@scut.edu.cn

    2015-11-15

    Recently, long persistent phosphors (LPPs) have been considered to be the most prominent candidates for biomedical applications. However, the LPPs suffer from a dramatic decrease in luminescence intensity after incorporation into the tissue. Therefore, it is very necessary to develop the more competitive LPPs and acquire the reproducible tissue imaging. Here, we propose and experimentally demonstrate an effective bifunctional La{sub 3}Ga{sub 5}GeO{sub 14}: Cr{sup 3+}, Nd{sup 3+} phosphor with the interesting characteristic of near-infrared long persistent phosphorescence and NIR-to-NIR Stokes luminescence. Cr{sup 3+} and Nd{sup 3+} ions are simultaneously selected as the emission centers in order to take advantage of the remarkable phosphorescence properties of Cr{sup 3+}, and the appropriate energy level characteristic of NIR-excitation band (808 nm) and NIR-emission (1064 nm), and the ability as the brilliant auxiliary to create more efficient defects of Nd{sup 3+}. The efficient dual-modal emission is, accordingly utilized to realize the convenient, high-resolution global detection and local imaging. - Highlights: • Dual mode phosphor with NIR long afterglow and NIR-to-NIR Stokes luminescence. • Increasing the persistent duration due to the codoping of Nd. • Avoiding the noteworthy overheating effect due to the strong absorption at 980 nm.

  11. Two sides of the same coin: TFIIH complexes in transcription and DNA repair.

    Science.gov (United States)

    Zhovmer, Alexander; Oksenych, Valentyn; Coin, Frédéric

    2010-04-13

    TFIIH is organized into a seven-subunit core associated with a three-subunit Cdk-activating kinase (CAK) module. TFIIH has roles in both transcription initiation and DNA repair. During the last 15 years, several studies have been conducted to identify the composition of the TFIIH complex involved in DNA repair. Recently, a new technique combining chromatin immunoprecipitation and western blotting resolved the hidden nature of the TFIIH complex participating in DNA repair. Following the recruitment of TFIIH to the damaged site, the CAK module is released from the core TFIIH, and the core subsequently associates with DNA repair factors. The release of the CAK is specifically driven by the recruitment of the DNA repair factor XPA and is required to promote the incision/excision of the damaged DNA. Once the DNA lesions have been repaired, the CAK module returns to the core TFIIH on the chromatin, together with the release of the repair factors. These data highlight the dynamic composition of a fundamental cellular factor that adapts its subunit composition to the cell needs.

  12. Two Sides of the Same Coin: TFIIH Complexes in Transcription and DNA Repair

    Directory of Open Access Journals (Sweden)

    Alexander Zhovmer

    2010-01-01

    Full Text Available TFIIH is organized into a seven-subunit core associated with a three-subunit Cdk-activating kinase (CAK module. TFIIH has roles in both transcription initiation and DNA repair. During the last 15 years, several studies have been conducted to identify the composition of the TFIIH complex involved in DNA repair. Recently, a new technique combining chromatin immunoprecipitation and western blotting resolved the hidden nature of the TFIIH complex participating in DNA repair. Following the recruitment of TFIIH to the damaged site, the CAK module is released from the core TFIIH, and the core subsequently associates with DNA repair factors. The release of the CAK is specifically driven by the recruitment of the DNA repair factor XPA and is required to promote the incision/excision of the damaged DNA. Once the DNA lesions have been repaired, the CAK module returns to the core TFIIH on the chromatin, together with the release of the repair factors. These data highlight the dynamic composition of a fundamental cellular factor that adapts its subunit composition to the cell needs.

  13. Increased rate of repair of ultraviolet-induced DNA strand breaks in mitogen stimulated lymphocytes

    Energy Technology Data Exchange (ETDEWEB)

    Hamlet, S.M.; Lavin, M.F.; Jennings, P.A. (Queensland Univ., St. Lucia (Australia). Dept. of Biochemistry; Queensland Univ., St. Lucia (Australia). Dept. of Veterinary Pathology; Queensland Univ. St. Lucia (Australia). Dept. of Public Health)

    1982-05-01

    Previous results have shown that phytohaemagglutinin-stimulated bovine lymphocytes exhibit a peak of ultraviolet-induced DNA repair synthesis 3 to 4 days after addition of mitogen. The level of repair synthesis was approximately tenfold higher than that in unstimulated lymphocytes. These studies have been extended to examine the rate of repair of strand breaks in U.V.-irradiated bovine lymphocytes. The extent of breakage of DNA was shown to be the same in mitogen-stimulated and unstimulated lymphocytes from two breeds of cattle, when determined by sedimentation of nucleoids on sucrose gradients. However, in mitogen-stimulated cells the time taken to repair DNA strand breaks was 6 hours compared with 12 hours in stationary phase lymphocytes after a U.V. dose of 5 J/m/sup 2/. These results suggest that the increased rate of repair of strand breaks is due to the induction of enzymes involved at the post-incision stage of DNA repair. Thus the increased level of repair synthesis observed in earlier work correlates with an increased rate of repair of DNA strand breaks in phytohaemagglutinin-stimulated bovine lymphocytes.

  14. Increased rate of repair of ultraviolet-induced DNA strand breaks in mitogen stimulated lymphocytes

    International Nuclear Information System (INIS)

    Hamlet, S.M.; Lavin, M.F.; Jennings, P.A.; Queensland Univ., St. Lucia; Queensland Univ. St. Lucia

    1982-01-01

    Previous results have shown that phytohaemagglutinin-stimulated bovine lymphocytes exhibit a peak of ultraviolet-induced DNA repair synthesis 3 to 4 days after addition of mitogen. The level of repair synthesis was approximately tenfold higher than that in unstimulated lymphocytes. These studies have been extended to examine the rate of repair of strand breaks in U.V.-irradiated bovine lymphocytes. The extent of breakage of DNA was shown to be the same in mitogen-stimulated and unstimulated lymphocytes from two breeds of cattle, when determined by sedimentation of nucleoids on sucrose gradients. However, in mitogen-stimulated cells the time taken to repair DNA strand breaks was 6 hours compared with 12 hours in stationary phase lymphocytes after a U.V. dose of 5 J/m 2 . These results suggest that the increased rate of repair of strand breaks is due to the induction of enzymes involved at the post-incision stage of DNA repair. Thus the increased level of repair synthesis observed in earlier work correlates with an increased rate of repair of DNA strand breaks in phytohaemagglutinin-stimulated bovine lymphocytes. (author)

  15. Decoding vigilance with NIRS.

    Science.gov (United States)

    Bogler, Carsten; Mehnert, Jan; Steinbrink, Jens; Haynes, John-Dylan

    2014-01-01

    Sustained, long-term cognitive workload is associated with variations and decrements in performance. Such fluctuations in vigilance can be a risk factor especially during dangerous attention demanding activities. Functional MRI studies have shown that attentional performance is correlated with BOLD-signals, especially in parietal and prefrontal cortical regions. An interesting question is whether these BOLD-signals could be measured in real-world scenarios, say to warn in a dangerous workplace whenever a subjects' vigilance is low. Because fMRI lacks the mobility needed for such applications, we tested whether the monitoring of vigilance might be possible using Near-Infrared Spectroscopy (NIRS). NIRS is a highly mobile technique that measures hemodynamics in the surface of the brain. We demonstrate that non-invasive NIRS signals correlate with vigilance. These signals carry enough information to decode subjects' reaction times at a single trial level.

  16. Pharmaceutical applications using NIR technology in the cloud

    Science.gov (United States)

    Grossmann, Luiz; Borges, Marco A.

    2017-05-01

    NIR technology has been available for a long time, certainly more than 50 years. Without any doubt, it has found many niche applications, especially in the pharmaceutical, food, agriculture and other industries due to its flexibility. There are a number of advantages over other existing analytical technologies we can list, for example virtually no need for sample preparation; usually NIR does not demand sample destruction and subsequent discard; NIR provides fast results; NIR does not require extensive operator training and carries small operating costs. However, the key point about NIR technology is the fact that it's more related to statistics than chemistry or, in other words, we are more concerned about analyzing and distinguishing features within the data than looking deep into the chemical entities themselves. A simple scan reading in the NIR range usually involves huge inflows of data points. Usually we decompose the signals into hundreds of predictor variables and use complex algorithms to predict classes or quantify specific content. NIR is all about math, especially by converting chemical information into numbers. Easier said than done. A NIR signal is a very complex one. Usually the signal responses are not specific to a particular material, rather, each grouṕs responses add up, thus providing low specificity of a spectral reading. This paper proposes a simple and efficient method to analyze and compare NIR spectra for the purpose of identifying the presence of active pharmaceutical ingredients in finished products using low cost NIR scanning devices connected to the internet cloud.

  17. True Lies: The Double Life of the Nucleotide Excision Repair Factors in Transcription and DNA Repair

    Directory of Open Access Journals (Sweden)

    Nicolas Le May

    2010-01-01

    Full Text Available Nucleotide excision repair (NER is a major DNA repair pathway in eukaryotic cells. NER removes structurally diverse lesions such as pyrimidine dimers, arising upon UV irradiation or bulky chemical adducts, arising upon exposure to carcinogens and some chemotherapeutic drugs. NER defects lead to three genetic disorders that result in predisposition to cancers, accelerated aging, neurological and developmental defects. During NER, more than 30 polypeptides cooperate to recognize, incise, and excise a damaged oligonucleotide from the genomic DNA. Recent papers reveal an additional and unexpected role for the NER factors. In the absence of a genotoxic attack, the promoters of RNA polymerases I- and II-dependent genes recruit XPA, XPC, XPG, and XPF to initiate gene expression. A model that includes the growth arrest and DNA damage 45α protein (Gadd45α and the NER factors, in order to maintain the promoter of active genes under a hypomethylated state, has been proposed but remains controversial. This paper focuses on the double life of the NER factors in DNA repair and transcription and describes the possible roles of these factors in the RNA synthesis process.

  18. Repair of ultraviolet radiation damage in xeroderma pigmentosum cells belonging to complementation group F

    International Nuclear Information System (INIS)

    Hayakawa, H.; Ishizaki, K.; Yagi, T.; Takebe, H.; Inoue, M.; Sekiguchi, M.; Kyoto Univ.

    1981-01-01

    DNA-repair characteristics of xeroderma pigmentosum belonging to complementation group F were investigated. The cells exhibited an intermediate level of repair as measured in terms of (1) disappearance of T4 endonuclease-V-susceptible sites from DNA, (2) formation of ultraviolet-induced strand breaks in DNA, and (3) ultraviolet-induced unscheduled DNA synthesis during post-irradiation incubation. The impaired ability of XP3YO to perform unscheduled DNA synthesis was restored, to half the normal level, by the concomitant treatment with T4 endonuclease V and ultraviolet-inactivated Sendai virus. It is suggested that xeroderma pigmentosum cells of group F may be defective, at least in part, in the incision step of excision repair. (orig.)

  19. Expanded flap to repair facial scar left by radiotherapy of hemangioma.

    Science.gov (United States)

    Zhao, Donghong; Ma, Xinrong; Li, Jiang; Zhang, Lingfeng; Zhu, Baozhen

    2014-09-01

    This study explored the feasibility and clinical efficacy of expanded flap to repair facial scar left by radiotherapy of hemangioma. From March 2000 to April 2011, 13 cases of facial cicatrices left by radiotherapy of hemangioma have been treated with implantation surgery of facial skin dilator under local anesthesia. After water flood expansion for 1-2 months, resection of facial scar was performed, and wound repairing with expansion flap transfer was done. Thirteen patients were followed up from 5 months to 3 years. All patients tolerated flap transfer well; no contracture occurred during the facial expansion flap transfer. The incision scar was not obvious, and its color and texture were identical to surrounding skin. In conclusion, the use of expanded flap transfer to repair the facial scar left by radiotherapy of hemangioma is advantageous due to its simplicity, flexibility, and large area of repairing. This method does not affect the subsequent facial appearance.

  20. A novel CXCR4-targeted near-infrared (NIR) fluorescent probe (Peptide R-NIR750) specifically detects CXCR4 expressing tumors.

    Science.gov (United States)

    Santagata, Sara; Portella, Luigi; Napolitano, Maria; Greco, Adelaide; D'Alterio, Crescenzo; Barone, Maria Vittoria; Luciano, Antonio; Gramanzini, Matteo; Auletta, Luigi; Arra, Claudio; Zannetti, Antonella; Scala, Stefania

    2017-05-31

    C-X-C chemokine receptor 4 (CXCR4) is over-expressed in multiple human cancers and correlates with tumor aggressiveness, poor prognosis and increased risk for distant metastases. Imaging agents for CXCR4 are thus highly desirable. We developed a novel CXCR4-targeted near-infrared (NIR) fluorescent probe (Peptide R-NIR750) conjugating the new developed CXCR4 peptidic antagonist Peptide R with the NIR fluorescent dye VivoTag-S750. Specific CXCR4 binding was obtained in cells overexpressing human CXCR4 (B16-hCXCR4 and human melanoma cells PES43), but not in CXCR4 low expressing cells (FB-1). Ex vivo evaluation demonstrated that PepR-NIR750 specifically detects B16-hCXCR4-derived subcutaneous tumors and lung metastases. Fluorescence Molecular Tomography (FMT) in vivo imaging was performed on mice carrying subcutaneous CHO and CHO-CXCR4 tumors. PepR-NIR750 accumulates only in CXCR4-positive expressing subcutaneous tumors. Additionally, an intense NIR fluorescence signal was detected in PES43-derived lung metastases of nude mice injected with PepR-NIR750 versus mice injected with VivoTag-S750. With a therapeutic intent, mice bearing PES43-derived lung metastases were treated with Peptide R. A the dramatic reduction in PES43-derived lung metastases was detected through a decrease of the PepR-NIR750 signal. PepR-NIR750 is a specific probe for non-invasive detection of human high CXCR4-expressing tumors and metastatic lesion and thus a valuable tool for cancer molecular imaging.

  1. The Effect of Motion Artifacts on Near-Infrared Spectroscopy (NIRS Data and Proposal of a Video-NIRS System

    Directory of Open Access Journals (Sweden)

    Masayuki Satoh

    2017-11-01

    Full Text Available Aims: The aims of this study were (1 to investigate the influence of physical movement on near-infrared spectroscopy (NIRS data, (2 to establish a video-NIRS system which simultaneously records NIRS data and the subject’s movement, and (3 to measure the oxygenated hemoglobin (oxy-Hb concentration change (Δoxy-Hb during a word fluency (WF task. Experiment 1: In 5 healthy volunteers, we measured the oxy-Hb and deoxygenated hemoglobin (deoxy-Hb concentrations during 11 kinds of facial, head, and extremity movements. The probes were set in the bilateral frontal regions. The deoxy-Hb concentration was increased in 85% of the measurements. Experiment 2: Using a pillow on the backrest of the chair, we established the video-NIRS system with data acquisition and video capture software. One hundred and seventy-six elderly people performed the WF task. The deoxy-Hb concentration was decreased in 167 subjects (95%. Experiment 3: Using the video-NIRS system, we measured the Δoxy-Hb, and compared it with the results of the WF task. Δoxy-Hb was significantly correlated with the number of words. Conclusion: Like the blood oxygen level-dependent imaging effect in functional MRI, the deoxy-Hb concentration will decrease if the data correctly reflect the change in neural activity. The video-NIRS system might be useful to collect NIRS data by recording the waveforms and the subject’s appearance simultaneously.

  2. Using Massive Multivariate NIRS Data in Ryegrass

    DEFF Research Database (Denmark)

    Edriss, Vahid; Greve-Pedersen, Morten; Jensen, Christian S

    2015-01-01

    Near infrared spectroscopy (NIRS) analytical techniques is a simple, fast and low cost method of high dimensional phenotyping compared to usual chemical techniques. To use this method there is no need for special sample preparation. The aim of this study is to use NIRS data to predict plant traits...... (e.g. dry matter, protein content, etc.) for the next generation. In total 1984 NIRS data from 995 ryegrass families (first cut) were used. The Absorption of radiation in the region of 960 – 1690 nm in every 2 nm distance produced 366 bins to represent the NIRS spectrum. The amount of genetic...

  3. Decoding vigilance with NIRS.

    Directory of Open Access Journals (Sweden)

    Carsten Bogler

    Full Text Available Sustained, long-term cognitive workload is associated with variations and decrements in performance. Such fluctuations in vigilance can be a risk factor especially during dangerous attention demanding activities. Functional MRI studies have shown that attentional performance is correlated with BOLD-signals, especially in parietal and prefrontal cortical regions. An interesting question is whether these BOLD-signals could be measured in real-world scenarios, say to warn in a dangerous workplace whenever a subjects' vigilance is low. Because fMRI lacks the mobility needed for such applications, we tested whether the monitoring of vigilance might be possible using Near-Infrared Spectroscopy (NIRS. NIRS is a highly mobile technique that measures hemodynamics in the surface of the brain. We demonstrate that non-invasive NIRS signals correlate with vigilance. These signals carry enough information to decode subjects' reaction times at a single trial level.

  4. Simultaneous demonstration of UV-type and ionizing radiation-type DNA repair by the nucleoid sedimentation technique

    International Nuclear Information System (INIS)

    Aldenhoff, P.; Sperling, K.

    1984-01-01

    The nucleoid sedimentation technique is one of the most sensitive methods for measuring DNA excision repair. With this technique, it is shown that both UV- and ionizing radiation-type repair (the latter induced by bleomycin) can be discriminated in HeLa and normal diploid cells using 1-β-D-arabinofuranosylcytosine. The latter compound inhibits UV-type repair synthesis, and thus causes DNA breaks due to enzymic incision to persist, but has no effect on rejoining DNA after ionizing radiation-type damage. It was then possible to prove that 4-nitroquinoline-1-oxide induces both types of lesions which are repaired simultaneously. This effect could be demonstrated in HeLa and normal human diploid cells in a single experimental set-up. (Auth.)

  5. An Osteoinductive Polymer Composite for Cranial and Maxillofacial Bone Repair,

    Science.gov (United States)

    1985-01-01

    a suitable level of anesthesia , a semi-lunar incision was made in the midline from the superior sagittal crest to the middle of the nasal bone. The...internal fixation of Fractures, and as intraosseous bone repair materials. A promising use for these polymers has been as carriers for osteogenic...acids. Oral Surg. 37:142, 1974. 7. Getter, L., Cutright, D.E., Bhaskar, S.N., and Augsburg, J.K. A biodegradable intraosseous apliance in the

  6. Incisive canal deflation for correct implant placement: case report.

    Science.gov (United States)

    Spin-Neto, Rubens; Bedran, Telma Blanca Lombardo; de Paula, Wagner Nunes; de Freitas, Rubens Moreno; de Oliveira Ramalho, Lizeti Toledo; Marcantonio, Elcio

    2009-12-01

    This article is a case report of a patient in whom the prosthetic planning indicated the necessity of an incisive canal deflation for the correct installation of an implant that is to be osseointegrated. In the reopening phase after the bone graft installation, the incisive canal deflation (biopsy of its content) was done and titanium implants were installed with one of them invading the anatomical space occupied previously by the incisive canal. The biopsy analysis showed fragments of the incisive artery and nerve, which are responsible for the anterior upper-tooth pulp, the periodontium vascularization and the innervation. From the anastomosis present along with other structures allied with the absence of teeth in the region, there was no detriment to the patient caused by the deflation. Incisive canal deflation is a viable technique in implantology. It can permit ideal prosthetic planning with no detriment to the patient.

  7. Characterization of a mutant rat kangaroo cell line with alterations in the cell cycle and DNA repair

    Directory of Open Access Journals (Sweden)

    Miyaji E.N.

    2000-01-01

    Full Text Available Using a positive selection system for isolating DNA replication and repair related mutants, we isolated a clone from a rat kangaroo cell line (PtK2 that has increased sensitivity to UV light. Characterization of this clone indicated normal post-replication repair after UV irradiation, and normal removal rates of cyclobutane pyrimidine dimers and pyrimidine(6-4pyrimidone photoproducts by excision repair. However, this cell line has decreased ability to make early incisions on damaged DNA, possibly indicating a defect in preferential repair of actively transcribed genes, and a slower cell proliferation rate, including a longer S-phase. This phenotype reinforces the present notion that control of key mechanisms in cell metabolism, such as cell cycle control, repair, transcription and cell death, can be linked.

  8. Removal of misincorporated ribonucleotides from prokaryotic genomes: an unexpected role for nucleotide excision repair.

    Directory of Open Access Journals (Sweden)

    Alexandra Vaisman

    2013-11-01

    Full Text Available Stringent steric exclusion mechanisms limit the misincorporation of ribonucleotides by high-fidelity DNA polymerases into genomic DNA. In contrast, low-fidelity Escherichia coli DNA polymerase V (pol V has relatively poor sugar discrimination and frequently misincorporates ribonucleotides. Substitution of a steric gate tyrosine residue with alanine (umuC_Y11A reduces sugar selectivity further and allows pol V to readily misincorporate ribonucleotides as easily as deoxynucleotides, whilst leaving its poor base-substitution fidelity essentially unchanged. However, the mutability of cells expressing the steric gate pol V mutant is very low due to efficient repair mechanisms that are triggered by the misincorporated rNMPs. Comparison of the mutation frequency between strains expressing wild-type and mutant pol V therefore allows us to identify pathways specifically directed at ribonucleotide excision repair (RER. We previously demonstrated that rNMPs incorporated by umuC_Y11A are efficiently removed from DNA in a repair pathway initiated by RNase HII. Using the same approach, we show here that mismatch repair and base excision repair play minimal back-up roles in RER in vivo. In contrast, in the absence of functional RNase HII, umuC_Y11A-dependent mutagenesis increases significantly in ΔuvrA, uvrB5 and ΔuvrC strains, suggesting that rNMPs misincorporated into DNA are actively repaired by nucleotide excision repair (NER in vivo. Participation of NER in RER was confirmed by reconstituting ribonucleotide-dependent NER in vitro. We show that UvrABC nuclease-catalyzed incisions are readily made on DNA templates containing one, two, or five rNMPs and that the reactions are stimulated by the presence of mispaired bases. Similar to NER of DNA lesions, excision of rNMPs proceeds through dual incisions made at the 8(th phosphodiester bond 5' and 4(th-5(th phosphodiester bonds 3' of the ribonucleotide. Ribonucleotides misinserted into DNA can therefore be

  9. Clear corneal incision leakage after phacoemulsification--detection using povidone iodine 5%.

    Science.gov (United States)

    Chee, Soon-Phaik

    2005-01-01

    The purpose of this work was to study the incidence of clear corneal wound leakage at the conclusion of standard co-axial phacoemulsification in a prospective observational series of 100 consecutive cataract cases in a single surgeon's institutional practice. At the conclusion of standard co-axial phacoemulsification using a 2.75 mm temporal single plane clear corneal incision with a 1 mm clear corneal side-port incision, the wounds were hydrated and checked for water-tightness. Povidone iodine 5% (P-I) was then evenly dripped over the cornea and the wounds were inspected visually. Any leakage of aqueous observed was recorded. The amount of leakage was graded as small or large from each wound. Leaky wounds were further hydrated and retested with P-I until sealed. Wound integrity was reassessed on the first postoperative day by use of fluorescein. Of the 100 cases, wound leakage was observed for 31 eyes (31%)-ten main incisions, nineteen side-port incisions, and both incisions in two cases. Wound leakage was easily detected as a ribbon of clear fluid streaming from the incision amid a pool of brown solution. Povidone iodine was not observed within the tract in any incision. All wound leakage was small except for one from the main incision and two from the side-port incision. None of the eyes developed wound leakage the day after surgery and none developed endophthalmitis. In conclusion, leakage from clear corneal incisions at the conclusion of phacoemulsification occurs in almost a third of cases, predominantly from the side incision. It is easily detected by use of the P-I test.

  10. Effects of two different incision phacoemulsification on corneal astigmatism

    Directory of Open Access Journals (Sweden)

    Lu Huo

    2014-12-01

    Full Text Available AIM:To compare the effect of different incision in corneal astigmatism after phacoemulsification. METHODS: Totally 88 cases(122 eyeswith pure cataract were randomly divided into two groups. Forty cases(60 eyeswere clarity corneal incision in group A, and 48 cases(62 eyeswere sclera tunnel incision in group B. Mean corneal astigmatism, surgically induced astigmatism(SIA, uncorrected visual acuity(UCVAand best correct vision acuity(BCVAwere observed in pre- and post-operation at 1d; 1wk; 1mo.RESULTS: The mean astigmatism had statistically significant difference between two groups at 1d; 1wk; 1mo after operation(PPP>0.05. UCVA≥0.5 and BCVA≥0.8 had statistically significant difference at 1d; 1wk(PP>0.05.CONCLUSION: Phacoemulsification with scleral tunnel incision remove combined intraocular lens(IOLimplantation has small changes to corneal astigmatism. By selecting personalized corneal incision according to the corneal topography might be more beneficial.

  11. Single incision laparoscopic colorectal resection: Our experience

    Directory of Open Access Journals (Sweden)

    Chinnusamy Palanivelu

    2012-01-01

    Full Text Available Background: A prospective case series of single incision multiport laparoscopic colorectal resections for malignancy using conventional laparoscopic trocars and instruments is described. Materials and Methods: Eleven patients (seven men and four women with colonic or rectal pathology underwent single incision multiport laparoscopic colectomy/rectal resection from July till December 2010. Four trocars were placed in a single transumblical incision. The bowel was mobilized laparoscopically and vessels controlled intracorporeally with either intra or extracorporeal anastomosis. Results: Three patients had carcinoma in the caecum, one in the hepatic flexure, two in the rectosigmoid, one in the descending colon, two in the rectum and two had ulcerative pancolitis (one with high grade dysplasia and another with carcinoma rectum. There was no conversion to standard multiport laparoscopy or open surgery. The median age was 52 years (range 24-78 years. The average operating time was 130 min (range 90-210 min. The average incision length was 3.2 cm (2.5-4.0 cm. There were no postoperative complications. The average length of stay was 4.5 days (range 3-8 days. Histopathology showed adequate proximal and distal resection margins with an average lymph node yield of 25 nodes (range 16-30 nodes. Conclusion: Single incision multiport laparoscopic colorectal surgery for malignancy is feasible without extra cost or specialized ports/instrumentation. It does not compromise the oncological radicality of resection. Short-term results are encouraging. Long-term results are awaited.

  12. Diathermy versus scalpel incisions for open cholecystectomy comparative study

    International Nuclear Information System (INIS)

    Ali, M.A.; Niazi, W.A.K.

    2014-01-01

    The aim of the study was to make a comparison between skin incisions made with electrocautery versus scalpel in terms of their safety, efficacy and post-operative complications. Design: A randomized controlled study. Setting: The study was conducted in Combined Military Hospital (CMH) Kharian, Pakistan airforce (PAF) Hospital Sargodha. Duration of Study: May 2008 to August 2011. Patients and Methods: Ninety seven patients who underwent open cholecystectomy were randomly divided into two groups on the basis of the use of electrocautery versus steel scalpel for making skin incision and sub-cutaneous tissue dissection. Parameters recorded were, time taken from skin incision to full incising of the peritoneum, length of the wound, amount of blood loss during this step of surgery in each group. Post-operative pain scoring using visual analogue scale was done. Wound complications such as infection, haematoma/seroma and dehiscence were noted too. One month of follow up was recorded in each group. Subsequently a comparison of these findings was done. Results: Incision time (sec/cm/sub 2/) was longer in scalpel group than in diathermy group (p = 0.001), whereas, incision blood loss (ml/cm/sub 2/) was significantly less in diathermy group than in scalpel group (p = 0.03). There was no difference in post-operative pain perception as delineated by visual pain analogue scoring system between the two groups (p = 0.57). Post-operative wound complications and the final healing of wound at 01 month of follow-up were almost similar in both groups. Conclusion: Electrocautery may be used safely without any untoward complication in making skin incision and sub-cutaneous tissue dissection with an advantage of reduced incision time and and less blood loss. (author)

  13. [Application of the xenogenic acellular dermal matrix membrane application used in the postoperative tissue shortage repair].

    Science.gov (United States)

    Bai, Yanxia; Yan, Liying; Zhang, Shaoqiang; Shao, Yuan; Yao, Xiaobao; Li, Honghui; Zhao, Ruimin; Zhao, Qian; Zhang, Pengfei; Yang, Qi

    2014-09-01

    To observe the short-term and long-term curative effect of the xenogenic acellular dermal matrix membrane (or joint muscle flap transfer) application used in the 82 cases postoperative tissue shortage repair that after the head neck carcinoma resection. To held the 82 cases head neck carcinoma postoperative mucosa shortage repaired after resection by the xenogenic acellular dermal matrix membrane (or joint muscle flap transfer), 65 cases mucosa shortage wound be directly covered by the repair membrane and the other 17 cases mucosa shortage wound be repaired by the tranfered muscle tissue flap with the repair membrane covered; 53 cases underwent additional postoperative radiotherapy between 2-4 weeks and follow-up in 1, 3, 6, 12, 18, 24, 30, 36, 48, 60 months and observed the operation site repair process through the electronic laryngoscope, observed the patients respiration, swallow, phonation function. Seventy-seven cases patients operation incision reached I phase healing standard, another 5 cases patients operation incision reached II phase healing standard because of the wound infection and fully-recovered through the local wound drainage,dressing process. All the patients tracheal cannula,the stomach tube be extubated successfully and without the local cicatricial constriction occurred. Seventy-eight cases follow up period reached 1 year including 53 cases who underwent postoperative radiotherapy, 49 cases follow up period reached 3 years including 32 cases who underwent postoperative radiotherapy, 14 cases follow up period reached 5 years including 12 cases who underwent postoperative radiotherapy. The patients with static local lesions discovered no reaction such as exclusion, allergy. The application of xenogenic acellular dermal matrix membrane (or joint muscle flap transfer used in in the postoperative tissue shortage repair that after the head neck carcinoma resection have several advantage such as comparatively easily implementation, operation safety

  14. Concurrent fNIRS-fMRI measurement to validate a method for separating deep and shallow fNIRS signals by using multidistance optodes

    Science.gov (United States)

    Funane, Tsukasa; Sato, Hiroki; Yahata, Noriaki; Takizawa, Ryu; Nishimura, Yukika; Kinoshita, Akihide; Katura, Takusige; Atsumori, Hirokazu; Fukuda, Masato; Kasai, Kiyoto; Koizumi, Hideaki; Kiguchi, Masashi

    2015-01-01

    Abstract. It has been reported that a functional near-infrared spectroscopy (fNIRS) signal can be contaminated by extracerebral contributions. Many algorithms using multidistance separations to address this issue have been proposed, but their spatial separation performance has rarely been validated with simultaneous measurements of fNIRS and functional magnetic resonance imaging (fMRI). We previously proposed a method for discriminating between deep and shallow contributions in fNIRS signals, referred to as the multidistance independent component analysis (MD-ICA) method. In this study, to validate the MD-ICA method from the spatial aspect, multidistance fNIRS, fMRI, and laser-Doppler-flowmetry signals were simultaneously obtained for 12 healthy adult males during three tasks. The fNIRS signal was separated into deep and shallow signals by using the MD-ICA method, and the correlation between the waveforms of the separated fNIRS signals and the gray matter blood oxygenation level–dependent signals was analyzed. A three-way analysis of variance (signal depth×Hb kind×task) indicated that the main effect of fNIRS signal depth on the correlation is significant [F(1,1286)=5.34, pdeep and shallow signals, and the accuracy and reliability of the fNIRS signal will be improved with the method. PMID:26157983

  15. Treatment of bilateral mammary ptosis and pectus excavatum through the same incision in one surgical stage

    Directory of Open Access Journals (Sweden)

    Fernando Passos Rocha

    Full Text Available CONTEXT: Congenital deformities of the anterior thoracic wall are characterized by unusual development of the costal cartilages. All these medical conditions are frequently associated with a variety of breast deformities. Several surgical techniques have been described for correcting them, going from sternochondroplasty to, nowadays, minimally invasive techniques and silicone prosthesis implantation. CASE REPORT: The present article reports the case of a young female patient who presented bilateral mammary ptosis and moderate pectus excavatum that caused a protrusion between the eighth and the tenth ribs and consequent esthetic disharmony. The proposed surgical treatment included not only subglandular breast implants of polyurethane, but also resection of part of the rib cartilage and a bone segment from the eighth, ninth and tenth ribs by means of a single submammary incision in order to make the scar minimally visible. Correction through a single incision benefited the patient and provided an excellent esthetic result. CONCLUSIONS: The techniques used to repair bilateral mammary ptosis and pectus excavatum by plastic and thoracic surgery teams, respectively, have been shown to be efficient for correcting both deformities. An excellent esthetic and functional result was obtained, with consequent reestablishment of the patient's self-esteem.

  16. Restoration of u.v.-induced excision repair in Xeroderma D cells transfected with the denV gene of bacteriophage T4

    International Nuclear Information System (INIS)

    Arrand, J.E.; Squires, S.; Bone, N.M.; Johnson, R.T.

    1987-01-01

    The heritable DNA repair defect in human Xeroderma D cells, resulting in failure to incise at u.v. light-induced pyrimidine dimers, has been partially but stably corrected by transfection of immortalised cells with the denV pyrimidine dimer glycosylase gene of bacteriophage T4. Transfectants selected either for a dominant marker on the mammalian vector carrying the prokaryotic gene or for dominant marker plus resistance to killing by u.v. light, were shown to express the denV gene to varying degrees. denV expression results in significant phenotypic change in the initially repair-deficient, u.v.-hypersensitive cells. Increased resistance to u.v. light and more rapid recovery of replicative DNA synthesis following u.v. irradiation were correlated with improved repair DNA synthesis and with a novel dimer incision capability present in denV transfected Xeroderma cells but not as evident in transfected normal cells. Most transfectants contain a single integrated copy of the denV gene; increase in denV copy number does not result in either increased gene expression or enhanced survival to u.v. light. Results show that expression of a heterologous prokaryotic repair gene can partially compensate for the genetic defect in a human Xeroderma D cell. (author)

  17. Single-incision laparoscopic cholecystectomy with needle graspers.

    Science.gov (United States)

    Sumiyoshi, Kinjiro; Sato, Norihiro; Akagawa, Shin; Hirano, Tatsuya; Koikawa, Kazuhiro; Horioka, Kohei; Ozono, Keigo; Fujiwara, Kenji; Tanaka, Masao; Sada, Masayuki

    2012-01-01

    Single-incision laparoscopic cholecystectomy (SILC) is a promising alternative to standard multi-incision laparoscopic cholecystectomy (LC). However, generalization of SILC is still hampered by technical difficulties mainly associated with the lack of trocars used for retraction of the gallbladder. We therefore developed a modified method of SILC with the use of needle graspers (SILC-N) for optimal retraction and exposure. In addition to two trocars inserted through a single transumbilical incision, two needle ports were placed on the right subcostal and lateral abdominal wall, through which needle graspers were used for retraction of the gallbladder. Since December, 2009, 12 patients with symptomatic cholelithiasis were treated by SILC-N. SILC-N was successfully performed in all but one patient requiring a conversion to the 4-port LC with a mean operative time of 71.5 (48-107) minutes. None of the patients experienced intraoperative or postoperative complications. The transumbilical incision and pinholes for needle graspers were almost invisible on discharge. Our preliminary results suggest that SILC-N is a simple, safe and feasible technique of cholecystectomy offering similar postoperative recovery and better cosmetic outcome as compared to conventional LC.

  18. Single-incision laparoscopic surgery for pyloric stenosis.

    Science.gov (United States)

    Kozlov, Yury; Novogilov, Vladimir; Podkamenev, Alexey; Rasputin, Andrey; Weber, Irina; Solovjev, Alexey; Yurkov, Pavel

    2012-04-01

    Laparoscopy is the most common procedure for correction of congenital pyloric stenosis. The standard laparoscopic approach is based on the three-port technique. In contrast to the standard laparoscopic technique, the single-incision laparoscopic surgery (SILS) requires only one incision. We report on our experience with this surgical approach. Between September 2009 and August 2010 a total of 24 children underwent a laparoscopic pyloromyotomy, 12 in SILS technique. The single incision was carried through the center of the umbilicus. The working instruments were introduced in a two-dimensional direction into the peritoneal cavity via the same umbilical incision. The two groups were compared for patients' demographics, operative report and early postoperative outcomes. All SILS procedures were performed successfully with no conversion rate. There were no differences in the preoperative parameters between the two groups regarding age before surgery and body weight at operation. Operative time and time of full enteral intake was similar to comparable procedures with usage of a standard laparoscopic approach. There were no operative or postoperative complications. The early experience described in this study confirms that SILS can be applied for treatment of pyloric stenosis with outcomes similar to the standard laparoscopic surgery.

  19. APE1 incision activity at abasic sites in tandem repeat sequences.

    Science.gov (United States)

    Li, Mengxia; Völker, Jens; Breslauer, Kenneth J; Wilson, David M

    2014-05-29

    Repetitive DNA sequences, such as those present in microsatellites and minisatellites, telomeres, and trinucleotide repeats (linked to fragile X syndrome, Huntington disease, etc.), account for nearly 30% of the human genome. These domains exhibit enhanced susceptibility to oxidative attack to yield base modifications, strand breaks, and abasic sites; have a propensity to adopt non-canonical DNA forms modulated by the positions of the lesions; and, when not properly processed, can contribute to genome instability that underlies aging and disease development. Knowledge on the repair efficiencies of DNA damage within such repetitive sequences is therefore crucial for understanding the impact of such domains on genomic integrity. In the present study, using strategically designed oligonucleotide substrates, we determined the ability of human apurinic/apyrimidinic endonuclease 1 (APE1) to cleave at apurinic/apyrimidinic (AP) sites in a collection of tandem DNA repeat landscapes involving telomeric and CAG/CTG repeat sequences. Our studies reveal the differential influence of domain sequence, conformation, and AP site location/relative positioning on the efficiency of APE1 binding and strand incision. Intriguingly, our data demonstrate that APE1 endonuclease efficiency correlates with the thermodynamic stability of the DNA substrate. We discuss how these results have both predictive and mechanistic consequences for understanding the success and failure of repair protein activity associated with such oxidatively sensitive, conformationally plastic/dynamic repetitive DNA domains. Published by Elsevier Ltd.

  20. [In hospital and mid-term outcome of patients with NIR stent implantation: multicenter ESPORT-NIR registry].

    Science.gov (United States)

    Iñiguez, A; García, E; Seabra, R; Bordes, P; Bethencourt, A; Rigla, J

    2001-05-01

    Despite improvements in the results and techniques of catheter-based revascularization, few studies have evaluated the clinical results of the application of new stent designs. We describe the in-hospital and mid-term outcome of patients undergoing a stent NIR implantation. At least 1 Stent NIR was implanted in 1.004 patients (1.136 lesions) recruited from 50 centers in an international, multicenter, prospective, registry (Spain and Portugal NIR stent registry). Inclusion criteria were objective coronary ischemia related to a severe de novo lesion or first restenosis in native vessels with a reference diameter >= 2.75 mm. The primary end-point was the incidence of major adverse cardiac events within the first 7 months of follow-up. The mean age of the patients was 60 years and 82% were male. Angioplasty was indicated due to unstable angina in 61% of the cases. Stent implantation was successfully achieved in 99.6%. Clinical success (angiographic success without in-hospital major events) was achieved in 98.6% of patients. The rate of angiographic restenosis (> 50% stenosis narrowing) was 16% (CI 95%; 11.7-21.2). The accumulated major cardiac adverse event rate at seven months of follow-up was 8.7%: death (0.9%), acute myocardial infarction (1.2%) and target lesion revascularization (6.6%). In the wide setting of the population included in the ESPORT-NIR registry, stent NIR implantation was a highly effective therapy with a good mid-term clinical and angiographic outcome.

  1. Time domain functional NIRS imaging for human brain mapping.

    Science.gov (United States)

    Torricelli, Alessandro; Contini, Davide; Pifferi, Antonio; Caffini, Matteo; Re, Rebecca; Zucchelli, Lucia; Spinelli, Lorenzo

    2014-01-15

    This review is aimed at presenting the state-of-the-art of time domain (TD) functional near-infrared spectroscopy (fNIRS). We first introduce the physical principles, the basics of modeling and data analysis. Basic instrumentation components (light sources, detection techniques, and delivery and collection systems) of a TD fNIRS system are described. A survey of past, existing and next generation TD fNIRS systems used for research and clinical studies is presented. Performance assessment of TD fNIRS systems and standardization issues are also discussed. Main strengths and weakness of TD fNIRS are highlighted, also in comparison with continuous wave (CW) fNIRS. Issues like quantification of the hemodynamic response, penetration depth, depth selectivity, spatial resolution and contrast-to-noise ratio are critically examined, with the help of experimental results performed on phantoms or in vivo. Finally we give an account on the technological developments that would pave the way for a broader use of TD fNIRS in the neuroimaging community. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.

  2. NIRS - Near infrared spectroscopy - investigations in neurovascular diseases

    DEFF Research Database (Denmark)

    Schytz, Henrik Winther

    2015-01-01

    The purpose of this thesis was to explore and develop methods, where continuous wave near infrared spectroscopy (CW-NIRS) can be applied in different neurovascular diseases, in order to find biological markers that are useful in clinical neurology. To develop a new method to detect changes...... tomography (133Xe-SPECT) and the corrected BFI value. It was concluded, that it was not possible to obtain reliable BFI data with the ICG CW-NIRS method. NIRS measurements of low frequency oscillations (LFOs) may be a reliable method to investigate vascular alterations in neurovascular diseases......, but this requires an acceptable LFOs variation between hemispheres and over time in the healthy brain. The second study therefore investigated day-to-day and hemispheric variations in LFOs with NIRS. It was shown that NIRS might be useful in assessing LFOs between hemispheres, as well as interhemispheric phase...

  3. Transurethral incision of urethral diverticulum in the female

    DEFF Research Database (Denmark)

    Miskowiak, J; Honnens de Lichtenberg, M

    1989-01-01

    A new technique of transurethral incision of urethral diverticulum was successfully used in two women. The method described is safe, simple and shortens operating time.......A new technique of transurethral incision of urethral diverticulum was successfully used in two women. The method described is safe, simple and shortens operating time....

  4. Manipulating chromosome structure and metaphase status with ultraviolet light and repair synthesis inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Mullinger, A.M.; Johnson, R.T. (Cambridge Univ. (UK). Dept. of Zoology)

    1985-02-01

    DNA repair occurs in metaphase-arrested cells in response to ultraviolet irradiation. In the presence of the repair synthesis inhibitors, hydroxyurea and 1-..beta..-D-arabinofuranosylcytosine, the chromosomes of such cells are decondensed. The dose response of chromosome decondensation varies between different cell types. In human cells defective in excision repair there is much less chromosome decondensation in response to the same ultraviolet dose and time of repair inhibition. However, a simian virus 40-transformed muntjac cell displays pronounced chromosome decondensation but has limited incision ability. Both chromosome decondensation and single-strand break accumulation in the presence of inhibitors are reversed when DNA precursors are provided, but reversal after higher ultraviolet doses and longer period of incubation leads to recondensed chromosomes that are fragmented. Although the chromosomes of repair-inhibited metaphase cells are decondensed in fixed preparations, their morphology appears normal in intact cells. The cells also retain a capacity to induce prematurely condensed chromosomes (PCC) when fused with interphase cells: compared with control mitotic cells, the speed of induction is sometimes reduced but the final amount of PCC produced is similar.

  5. Minimal abdominal incisions

    Directory of Open Access Journals (Sweden)

    João Carlos Magi

    2017-04-01

    Full Text Available Minimally invasive procedures aim to resolve the disease with minimal trauma to the body, resulting in a rapid return to activities and in reductions of infection, complications, costs and pain. Minimally incised laparotomy, sometimes referred to as minilaparotomy, is an example of such minimally invasive procedures. The aim of this study is to demonstrate the feasibility and utility of laparotomy with minimal incision based on the literature and exemplifying with a case. The case in question describes reconstruction of the intestinal transit with the use of this incision. Male, young, HIV-positive patient in a late postoperative of ileotiflectomy, terminal ileostomy and closing of the ascending colon by an acute perforating abdomen, due to ileocolonic tuberculosis. The barium enema showed a proximal stump of the right colon near the ileostomy. The access to the cavity was made through the orifice resulting from the release of the stoma, with a lateral-lateral ileo-colonic anastomosis with a 25 mm circular stapler and manual closure of the ileal stump. These surgeries require their own tactics, such as rigor in the lysis of adhesions, tissue traction, and hemostasis, in addition to requiring surgeon dexterity – but without the need for investments in technology; moreover, the learning curve is reported as being lower than that for videolaparoscopy. Laparotomy with minimal incision should be considered as a valid and viable option in the treatment of surgical conditions. Resumo: Procedimentos minimamente invasivos visam resolver a doença com o mínimo de trauma ao organismo, resultando em retorno rápido às atividades, reduções nas infecções, complicações, custos e na dor. A laparotomia com incisão mínima, algumas vezes referida como minilaparotomia, é um exemplo desses procedimentos minimamente invasivos. O objetivo deste trabalho é demonstrar a viabilidade e utilidade das laparotomias com incisão mínima com base na literatura e

  6. Shed a light of wireless technology on portable mobile design of NIRS

    Science.gov (United States)

    Sun, Yunlong; Li, Ting

    2016-03-01

    Mobile internet is growing rapidly driven by high-tech companies including the popular Apple and Google. The wireless mini-NIRS is believed to deserve a great spread future, while there is sparse report on wireless NIRS device and even for the reported wireless NIRS, its wireless design is scarcely presented. Here we focused on the wireless design of NIRS devices. The widely-used wireless communication standards and wireless communication typical solutions were employed into our NIRS design and then compared on communication efficiency, distance, error rate, low-cost, power consumption, and stabilities, based on the requirements of NIRS applications. The properly-performed wireless communication methods matched with the characteristics of NIRS are picked out. Finally, we realized one recommended wireless communication in our NIRS, developed a test platform on wireless NIRS and tested the full properties on wireless communication. This study elaborated the wireless communication methods specified for NIRS and suggested one implementation with one example fully illustrated, which support the future mobile design on NIRS devices.

  7. Infectious morbidity, operative blood loss, and length of the operative procedure after cesarean delivery by method of placental removal and site of uterine repair.

    Science.gov (United States)

    Magann, E F; Washburne, J F; Harris, R L; Bass, J D; Duff, W P; Morrison, J C

    1995-12-01

    This study was done to determine the impact of the method of placental removal and the site of uterine repair on postcesarean infectious morbidity rates in women receiving prophylactic antibiotics at cesarean delivery. This prospective study included 284 women who underwent cesarean delivery and who were randomly assigned to four groups based on the method of placental removal and the site of uterine repair: group 1, spontaneous placental removal and in situ uterine repair; group 2, spontaneous placental removal and exteriorized uterine repair; group 3, manual placental removal and in situ uterine repair; and group 4, manual placental removal with exteriorized uterine repair. Exclusion criteria were repeat cesarean deliveries without labor, active infection at the time of cesarean delivery, and patient refusal to participate. There was no significant difference among the groups in maternal age, race, parity, weight, the length of time from rupture of membranes (ROM) or the number of vaginal examinations from ROM to cesarean delivery, or preoperative hematocrit. Intraoperatively, the type of uterine incision, anesthesia administered, incidence of meconium-stained amniotic fluid, Apgar scores, and cord gases were similar between groups. The incidence of postcesarean endometritis was greater in group 4 (32 [45 percent] of 71, p = 0.003) compared with group 1 (17 [24 percent] of 71), group 2 (12 [30 percent] of 71); and group 3 (13 [18 percent] of 71). Manual placental removal and exteriorization of the uterus for repair of the surgical incision increases the infectious morbidity rate in women receiving prophylactic antibiotics at the time of cesarean delivery and increases the length of hospitalization.

  8. Midline versus transverse incision for cesarean delivery in low-income countries

    DEFF Research Database (Denmark)

    Maaløe, Nanna; Aabakke, Anna J M; Secher, Niels J

    2014-01-01

    While transverse incision is the recommended entry technique for cesarean delivery in high-income countries, it is our experience that midline incision is still used routinely in many low-income settings. Accordingly, international guidelines lack uniformity on this matter. Although evidence...... is limited, the literature suggests important advantages of the transverse incision, with lower risk of long-term disabilities such as wound disruption and hernia. Also, potential extra time spent on this incision appears not to impact neonatal outcome. Therefore, we suggest that it is time for a change...

  9. Cosmetic effects of skin-crease camouflage incision versus longitudinal incision following carotid endarterectomy.

    Science.gov (United States)

    Kazimierczak, Arkadiusz; Rybicka, Anita; Rynio, Pawel; Gutowski, Piotr; Wiernicki, Ireneusz

    2018-03-01

    Despite the increasing use of carotid angioplasty and stenting (CAS), carotid endarterectomy (CEA) nonetheless remains a more medically beneficial method of treatment for carotid artery stenosis. Therefore, one possibility for progress within this procedure may be to use minimally invasive carotid surgery, especially when the scar is in plain sight: the use of the natural wrinkles (skin crease) as a camouflage of the skin incision provides significant cosmetic improvements. To compare the cosmetic effects of classic and trans-wrinkle CEA. To assess the distance between the carotid artery bifurcation (CAB) and the skin-crease incision whilst attempting CEA. It was a randomized prospective study with two groups: patients undergoing classic surgery (control group; n = 100) and skin-crease trans-wrinkle camouflaged CEA (study group; n = 100). Follow-up was at 2 months and 1 year. The medical results of the treatment were similar in both groups. The cumulative count of strokes and myocardial infarctions was 0.5% within 30 days, and after one year 3.5% (and 5.5% including cases of death). The superiority of the transverse crease being hidden compared to the conventional longitudinal technique was proven in the Patient and Observer Scar Assessment Scale (POSAS) score, respectively 11.4 ±1.0 vs. 14.1 ±3.4 (p = 0.0001) after 2 months and 13.5 ±2.8 vs. 14.1 ±3.4 (p = 0.039) after a year. Trans-wrinkle incision gives better cosmetic results, can be safely performed in most cases, and offers a comfortable approach during CEA.

  10. In vivo architectural analysis of clear corneal incisions using anterior segment optical coherence tomography.

    Science.gov (United States)

    Dupont-Monod, Sylvère; Labbé, Antoine; Fayol, Nicolas; Chassignol, Alexis; Bourges, Jean-Louis; Baudouin, Christophe

    2009-03-01

    To use anterior segment optical coherence tomography (AS-OCT) to analyze the in vivo architecture of clear corneal incisions after phacoemulsification using different techniques. Department of Ophthalmology, Quinze-Vingts National Ophthalmology Hospital, Paris, France. This prospective observational study analyzed clear corneal incisions used in phacoemulsification. All wounds were evaluated 1 day and 8 days postoperatively by AS-OCT (Visante). Incision architecture and pachymetry at the wound level were analyzed. Thirty-five clear corneal incisions were analyzed. Six eyes had 2.75 mm coaxial phacoemulsification, 19 had 2.20 mm microincision coaxial phacoemulsification, and 10 had 1.30 mm bimanual microincision phacoemulsification. The 1.30 mm incision had a straight-line configuration. The 2.20 mm and 2.75 mm incisions had an arcuate configuration. The angles of incidence of 1.30 mm incisions were greater than those of 2.20 mm incisions (P<.001). All incisions had slight corneal edema limited to the incision area. The edema was slightly greater around 1.30 mm incisions (mean pachymetry 1143 microm +/- 140 [SD]) than around 2.20 mm incisions (mean 1012 +/- 101 microm) (P = .001). Bimanual procedures had satisfactory endothelial apposition in the enlarged areas, where stromal edema was less than that surrounding the unenlarged 1.30 mm incisions. The 3 phacoemulsification techniques induced gaping of the endothelial edge, minor inadequate endothelial apposition, and mild stromal edema in the area of the clear corneal incisions. Bimanual microincision sleeveless phacoemulsification may alter the wound slightly more than coaxial 2.75 mm and microcoaxial 2.20 mm sleeved-tip phacoemulsification.

  11. Radiological findings after endoscopic incision of ureterocele

    International Nuclear Information System (INIS)

    Cheon, Jung Eun; Kim, In One; Seok, Eul Hye; Cha, Joo Hee; Choi, Gook Myung; Kim, Woo Sun; Yeon, Kyung Mo; Kim, Kwang Myung; Choi, Hwang; Cheon, Jung Eun; Seok, Eul Hye; Cha, Joo Hee; Choi, Guk Myung

    2001-01-01

    Endoscopic incision of ureterocele is considered a simple and safe method for decompression of urinary tract obstruction above ureterocele. The purpose of this study was to evaluate the radiological findings after endoscopic incision of ureterocele. We retrospectively reviewed the radiological findings (ultrasonography (US), intravenous urography, and voiding cystourethrography(VCU)) in 16 patients with ureterocele who underwent endoscopic incision (mean age at surgery, 15 months; M:F 3:13; 18 ureteroceles). According to the postoperative results, treatment was classified as successful when medical treatment was still required, and second operation when additional surgical treatment was required. Postoperative US (n=10) showed that in all patients, urinary tract obstruction was relieved: the kidney parenchima was thicker and the ureterocele was smaller. Intravenous urography (n=8), demonstrated that in all patients, urinary tract obstruction and the excretory function of the kidney had improved. Postoperative VCU indicated that in 92% of patients (12 of 13), endoscopic incision of the ureterocele led to vesicoureteral reflux(VUR). Of these twelve, seven (58%) showed VUR of more than grade 3, while newly developed VUR was seen in five of eight patients (63%) who had preoperative VCU. Surgery was successful in four patients (25%), partially successful in three (19%), and a second operation-on account of recurrent urinary tract infection and VUR of more than grase 3 during the follow-up period-was required by nine (56%). Although endoscopic incision of a ureterocele is a useful way of relieving urinary tract obstruction, an ensuing complication may be VUR. Postoperative US and intravenous urography should be used to evaluate parenchymal change in the kidney and improvement of uronary tract obstructon, while to assess the extend of VUR during the follow-up period , postoperative VCU is required

  12. Epoch making NIRS studies seen through citation trends

    International Nuclear Information System (INIS)

    Dan, Ippeita

    2009-01-01

    Near-infrared spectroscopy (NIRS) studies through citation trends are investigated of literature concerning only the brain function measurement and its methodology together with NIRS principle, technological development, present state and future view. Investigation is conducted firstly for the survey of important author name of those concerned papers in Web of Science and Google Scholar with search words of NIRS, brain and optical topography as an option. Second, >100 papers of those authors citing any of them are picked up and their papers are ranked in accordance with Web of Science citation number, of which top-nineteen are presented here. Impact and epoch making papers are reviewed with explanations of: the establishment of measuring technology of cerebral blood flow change and subsequent brain function by NIRS; development with multi-channel detection; simultaneous measurement with other imaging modalities; examination of NIRS validity; spatial analysis of NIRS; and measurement of brain function. The highest times of citation are 1,238 of the paper by F. F. Jobsis in 'Science' (1977). It should be noted that 10 of top 19 papers are those by Japanese authors. However, review articles omitted in the present literature survey are mostly described by foreign authors: an effort to systemize the concerned fields might be required in this country. (K.T.)

  13. Designing and testing a wearable, wireless fNIRS patch.

    Science.gov (United States)

    Abtahi, Mohammadreza; Cay, Gozde; Saikia, Manob Jyoti; Mankodiya, Kunal

    2016-08-01

    Optical brain monitoring using near infrared (NIR) light has got a lot of attention in order to study the complexity of the brain due to several advantages as oppose to other methods such as EEG, fMRI and PET. There are a few commercially available functional NIR spectroscopy (fNIRS) brain monitoring systems, but they are still non-wearable and pose difficulties in scanning the brain while the participants are in motion. In this work, we present our endeavors to design and test a low-cost, wireless fNIRS patch using NIR light sources at wavelengths of 770 and 830nm, photodetectors and a microcontroller to trigger the light sources, read photodetector's output and transfer data wirelessly (via Bluetooth) to a smart-phone. The patch is essentially a 3-D printed wearable system, recording and displaying the brain hemodynamic responses on smartphone, also eliminates the need for complicated wiring of the electrodes. We have performed rigorous lab experiments on the presented system for its functionality. In a proof of concept experiment, the patch detected the NIR absorption on the arm. Another experiment revealed that the patch's battery could last up to several hours with continuous fNIRS recording with and without wireless data transfer.

  14. DSC, FT-IR, NIR, NIR-PCA and NIR-ANOVA for determination of chemical stability of diuretic drugs: impact of excipients

    Directory of Open Access Journals (Sweden)

    Gumieniczek Anna

    2018-03-01

    Full Text Available It is well known that drugs can directly react with excipients. In addition, excipients can be a source of impurities that either directly react with drugs or catalyze their degradation. Thus, binary mixtures of three diuretics, torasemide, furosemide and amiloride with different excipients, i.e. citric acid anhydrous, povidone K25 (PVP, magnesium stearate (Mg stearate, lactose, D-mannitol, glycine, calcium hydrogen phosphate anhydrous (CaHPO4 and starch, were examined to detect interactions. High temperature and humidity or UV/VIS irradiation were applied as stressing conditions. Differential scanning calorimetry (DSC, FT-IR and NIR were used to adequately collect information. In addition, chemometric assessments of NIR signals with principal component analysis (PCA and ANOVA were applied.

  15. Sports hernia repair with adductor tenotomy.

    Science.gov (United States)

    Harr, J N; Brody, F

    2017-02-01

    Sports hernias, or athletic pubalgia, is common in athletes, and primarily involves injury to the fascia, muscles, and tendons of the inguinal region near their insertion onto the pubic bone. However, management varies widely, and rectus and adductor tenotomies have not been adequately described. The purpose of this manuscript is to demonstrate a suture repair and a rectus and adductor longus tenotomy technique for sports hernias. After magnetic-resonance-imaging confirmation of sports hernias with rectus and adductor tendonitis, 22 patients underwent a suture herniorrhaphy with adductor tenotomy. The procedure is performed through a 4-cm incision, and a fascial release of the rectus abdominis and adductor tenotomy is performed to relieve the opposing vector forces on the pubic bone. All 22 patients returned to their respective sports and regained their ability to perform at a high level, including professional status. No further surgery was required. In athletes with MRI confirmation of rectus and adductor longus injuries, tenotomies along with a herniorraphy may improve outcomes. A suture repair to reinforce the inguinal floor prevents mesh-related complications, especially in young athletes.

  16. Deep nirS amplicon sequencing of San Francisco Bay sediments enables prediction of geography and environmental conditions from denitrifying community composition.

    Science.gov (United States)

    Lee, Jessica A; Francis, Christopher A

    2017-12-01

    Denitrification is a dominant nitrogen loss process in the sediments of San Francisco Bay. In this study, we sought to understand the ecology of denitrifying bacteria by using next-generation sequencing (NGS) to survey the diversity of a denitrification functional gene, nirS (encoding cytchrome-cd 1 nitrite reductase), along the salinity gradient of San Francisco Bay over the course of a year. We compared our dataset to a library of nirS sequences obtained previously from the same samples by standard PCR cloning and Sanger sequencing, and showed that both methods similarly demonstrated geography, salinity and, to a lesser extent, nitrogen, to be strong determinants of community composition. Furthermore, the depth afforded by NGS enabled novel techniques for measuring the association between environment and community composition. We used Random Forests modelling to demonstrate that the site and salinity of a sample could be predicted from its nirS sequences, and to identify indicator taxa associated with those environmental characteristics. This work contributes significantly to our understanding of the distribution and dynamics of denitrifying communities in San Francisco Bay, and provides valuable tools for the further study of this key N-cycling guild in all estuarine systems. © 2017 Society for Applied Microbiology and John Wiley & Sons Ltd.

  17. Lateral Erosion Encourages Vertical Incision in a Bimodal Alluvial River

    Science.gov (United States)

    Gran, K. B.

    2015-12-01

    Sand can have a strong impact on gravel transport, increasing gravel transport rates by orders of magnitude as sand content increases. Recent experimental work by others indicates that adding sand to an armored bed can even cause armor to break-up and mobilize. These two elements together help explain observations from a bimodal sand and gravel-bedded river, where lateral migration into sand-rich alluvium breaks up the armor layer, encouraging further incision into the bed. Detailed bedload measurements were coupled with surface and subsurface grain size analyses and cross-sectional surveys in a seasonally-incised channel carved into the upper alluvial fan of the Pasig-Potrero River at Mount Pinatubo, Philippines. Pinatubo erupted in 1991, filling valleys draining the flanks of the volcano with primarily sand-sized pyroclastic flow debris. Twenty years after the eruption, sand-rich sediment inputs are strongly seasonal, with most sediment input to the channel during the rainy season. During the dry season, flow condenses from a wide braided planform to a single-thread channel in most of the upper basin, extending several km onto the alluvial fan. This change in planform creates similar unit discharge ranges in summer and winter. Lower sediment loads in the dry season drive vertical incision until the bed is sufficiently armored. Incision proceeds downstream in a wave, with increasing sediment transport rates and decreasing grain size with distance downstream, eventually reaching a gravel-sand transition and return to a braided planform. Incision depths in the gravel-bedded section exceeded 3 meters in parts of a 4 km-long study reach, a depth too great to be explained by predictions from simple winnowing during incision. Instead, lateral migration into sand-rich alluvium provides sufficient fine sediment to break up the armor surface, allowing incision to start anew and increasing the total depth of the seasonally-incised valley. Lateral migration is recorded in a

  18. Enhanced radiosensitivity and defective DNA repair in cultured fibroblasts derived from Rothmund Thomson syndrome patients

    Energy Technology Data Exchange (ETDEWEB)

    Smith, P J; Paterson, M C [Atomic Energy of Canada Ltd., Chalk River, Ontario. Radiation Biology Branch

    1982-01-01

    Rothmund Thomson syndrome (RTS) is an oculocutaneous and cancer-prone disorder in which enhanced carcinogen sensitivity, mediated through abnormal DNA metabolism, may be an associated factor. Cultured fibroblasts from 4 RTS patients have been examined for their colony-forming abilities and DNA repair capacities following ..gamma..-irradiation. 2 of the 4 RTS strains showed enhanced sensitivity following hypoxic ..gamma..-irradiation, and 1 of these 2 strains also showed enhanced sensitivity under oxic conditions. Defective DNA repair was implicated in the above abnormal responses to ..gamma..-radiation since both strains displayed reduced levels of repair synthesis and slow removal of radiogenic DNA lesions (assayed by their sensitivity to strand-incising activities present in protein extracts of Micrococcus luteus cells). A hypothesis is presented to rationalize the origin and heterogeneity of these laboratory phenotypes of RTS.

  19. The width of the incisive canal and labial alveolar bone of the incisive canal: an assessment on CT images

    International Nuclear Information System (INIS)

    Roh, Yang Gyun; Jang, Hyun Seon; Kim, Byung Ock; Kim, Jin Soo

    2006-01-01

    To assess the width of the labial alveolar bone of the incisive canal and the width of the incisive canal on spiral computed tomographic images of the anterior portion of the maxilla. Study materials included 38 CT scans taken for preoperative planning of implant placement. Axial cross-sectioned image entirely showing the incisive canal at an orifice to the oral cavity, middle portion, and an orifice to the nasal cavity and the diameter of the incisive canal at the middle portion were determined by two specialist using Digora for Windows 2.1. The statistical analyses were carried out using SPSS 12.0.1. When the maxillary central incisors remained, the mean labial alveolar bone width were 6.81±1.41 mm, 6.46±1.33 mm, and 7.91±1.33 mm. When the maxillary central incisors were missed the mean width were 5.42±2.20 mm, 6.23±2.29 mm, and 7.89±2.13 mm. The labial alveolar bone width at middle portion and an orifice to the nasal cavity were of no statistical significant difference according to presence of the maxillary central incisors (P>0.05). The width between oral cavity and nasal cavity, middle portion and to masal cavity revealed statistically significant difference (P<0.05)

  20. Nuclear management in manual small incision cataract surgery by snare technique

    Directory of Open Access Journals (Sweden)

    Bhattacharya Debasish

    2009-01-01

    Full Text Available Manual small incision cataract surgery has evolved into a popular method of cataract surgery in India. However, in supra hard cataract, bringing out the whole nucleus through the sclerocorneal flap valve incision becomes difficult. A bigger incision required in such cataracts loses its value action, as the internal incision and corneal valve slips beyond the limbus into sclera. Struggling with the supra hard cataracts through a regular small incision. Phacofracture in the anterior chamber becomes a useful option in these cases. In the snare technique, a stainless steel wire loop when lassoed around the nucleus in the anterior chamber constricts from the equator, easily dividing the hardest of the nuclei into two halves. The wire loop constricts in a controlled way when the second cannula of snare is pulled. The divided halves can easily be brought out by serrated crocodile forceps. This nuclear management can be safely performed through a smaller sclerocorneal flap valve incision where the corneal valve action is retained within the limbus without sutures, and the endothelium or the incision is not disturbed. However, the technique requires space in the anterior chamber to maneuver the wire loop and anterior chamber depth more than 2.5 mm is recommended. Much evidence to this wonderful technique is not available in literature, as its popularity grew through live surgical workshops and small interactive conferences.

  1. Watershed-scale modeling of streamflow change in incised montane meadows

    Science.gov (United States)

    Essaid, Hedeff I.; Hill, Barry R.

    2014-01-01

    Land use practices have caused stream channel incision and water table decline in many montane meadows of the Western United States. Incision changes the magnitude and timing of streamflow in water supply source watersheds, a concern to resource managers and downstream water users. The hydrology of montane meadows under natural and incised conditions was investigated using watershed simulation for a range of hydrologic conditions. The results illustrate the interdependence between: watershed and meadow hydrology; bedrock and meadow aquifers; and surface and groundwater flow through the meadow for the modeled scenarios. During the wet season, stream incision resulted in less overland flow and interflow and more meadow recharge causing a net decrease in streamflow and increase in groundwater storage relative to natural meadow conditions. During the dry season, incision resulted in less meadow evapotranspiration and more groundwater discharge to the stream causing a net increase in streamflow and a decrease in groundwater storage relative to natural meadow conditions. In general, for a given meadow setting, the magnitude of change in summer streamflow and long-term change in watershed groundwater storage due to incision will depend on the combined effect of: reduced evapotranspiration in the eroded meadow; induced groundwater recharge; replenishment of dry season groundwater storage depletion in meadow and bedrock aquifers by precipitation during wet years; and groundwater storage depletion that is not replenished by precipitation during wet years.

  2. Temporal versus Superior Limbal Incision: Any difference in visual ...

    African Journals Online (AJOL)

    Aim: To compare the visual outcome of a superiorly placed limbal incision with a temporal limbal incision in extracapsular cataract surgery. The main outcome measures are visual acuity and the degree of stigmatism based on refraction. Method: A retrospective non randomized comparative study. Medical records of 40 ...

  3. Meta-analysis of the effectiveness of surgical scalpel or diathermy in making abdominal skin incisions.

    LENUS (Irish Health Repository)

    Ahmad, Nasir Zaheer

    2012-02-01

    BACKGROUND: Surgical scalpels are traditionally used to make skin incisions. Diathermy incisions on contrary are less popular among the surgeons. The aim of this meta-analysis was to compare the effectiveness of both techniques and address the common fallacies about diathermy incisions. METHODS: A literature search of MEDLINE and Cochrane databases was done, using the keywords diathermy, cold scalpel, and incisions. Eleven clinical trials comparing both methods of making skin incisions were selected for meta-analysis. The end points compared included postoperative wound infection, pain in first 24 hours after surgery, time taken to complete the incisions, and incision-related blood loss. RESULTS: Postoperative wound infection rate was comparable in both techniques (P = 0.147, odds ratio = 1.257 and 95% CI = 0.923-1.711). Postoperative pain was significantly less with diathermy incisions in first 24 hours (P = 0.031, weighted mean difference = 0.852 and 95% CI = 0.076-1.628). Similarly, the time taken to complete the incision and incision-related blood loss was significantly less with diathermy incisions (95% CI = 0.245-0.502 and 0.548-1.020, respectively). CONCLUSION: Diathermy incisions are equally prone to get wound infection, as do the incisions made with scalpel. Furthermore, lower incidence of early postoperative pain, swiftness of the technique, and a reduced blood loss are the encouraging facts supporting routine use of diathermy for abdominal skin incisions after taking careful precautions.

  4. Vitamin C deficiency in weanling guinea pigs: differential expression of oxidative stress and DNA repair in liver and brain

    DEFF Research Database (Denmark)

    Lykkesfeldt, Jens; Trueba, Gilberto Perez; Poulsen, Henrik E

    2007-01-01

    Neonates are particularly susceptible to malnutrition due to their limited reserves of micronutrients and their rapid growth. In the present study, we examined the effect of vitamin C deficiency on markers of oxidative stress in plasma, liver and brain of weanling guinea pigs. Vitamin C deficiency...... incision repair (P = 0.014) were all increased, while protein oxidation decreased (P = 0.003). The results show that the selective preservation of brain ascorbate and induction of DNA repair in vitamin C-deficient weanling guinea pigs is not sufficient to prevent oxidative damage. Vitamin C deficiency may...

  5. [TECHNIQUES IN MITRAL VALVE REPAIR VIA A MINIMALLY INVASIVE APPROACH].

    Science.gov (United States)

    Ito, Toshiaki

    2016-03-01

    In mitral valve repair via a minimally invasive approach, resection of the leaflet is technically demanding compared with that in the standard approach. For resection and suture repair of the posterior leaflet, premarking of incision lines is recommended for precise resection. As an alternative to resection and suture, the leaflet-folding technique is also recommended. For correction of prolapse of the anterior leaflet, neochordae placement with the loop technique is easy to perform. Premeasurement with transesophageal echocardiography or intraoperative measurement using a replica of artificial chordae is useful to determine the appropriate length of the loops. Fine-tuning of the length of neochordae is possible by adding a secondary fixation point on the leaflet if the loop is too long. If the loop is too short, a CV5 Gore-Tex suture can be passed through the loop and loosely tied several times to stack the knots, with subsequent fixation to the edge of the leaflet. Finally, skill in the mitral valve replacement technique is necessary as a back-up for surgeons who perform minimally invasive mitral valve repair.

  6. Unilateral microform cleft lip repair: application of muscle tension line group theory.

    Science.gov (United States)

    Yin, Ningbei; Song, Tao; Wu, Jiajun; Chen, Bo; Ma, Hengyuan; Zhao, Zhenmin; Wang, Yongqian; Li, Haidong; Wu, Di

    2015-03-01

    In microform cleft lip repair, reconstructing the elaborate structures is difficult. We describe a new technique of unilateral microform cleft lip repair that is based on the muscle tension line group theory. According to the shape of Cupid bow, a different small incision is used without creating an obvious cutaneous scar. First, the nasolabial muscle around the nasal floor (the first auxiliary tension line group) is reconstructed, and then the orbicularis oris muscle around the philtrum (the second auxiliary tension line group) is reconstructed based on the muscle tension line group theory. From June 2006 to June 2012, the technique was used in 263 unilateral microform cleft lip repairs. For 18 months, 212 patients were followed up. The appearance of the nasal alar, nasal sill, philtrum, and Cupid bow peak improved. Most patients had a satisfactory appearance. Based on the muscle tension line group theory, using this technique offers the ability to adduct the nasal alar effectively to form a good nasal sill and philtrum.

  7. Excision repair in ataxia telangiectasia, Fanconi's anemia, Cockayne syndrome, and Bloom's syndrome after treatment with ultraviolet radiation and N-acetoxy-2-acetylaminofluorene

    International Nuclear Information System (INIS)

    Ahmed, F.E.; Setlow, R.B.

    1978-01-01

    Excision repair of damage due to ultraviolet radiation, N-acetoxy-2-acetylaminofluorene and a combination of both agents was studied in normal human fibroblasts and various cells from cancer prone patients (ataxia telangiectasia, Fanconi's anemia, Cockayne syndrome and Bloom's syndrome). Three methods giving similar results were used: unscheduled DNA synthesis by radioautography, photolysis of bromodeoxyuridine incorporated into parental DNA during repair, and loss of sites sensitive to an ultraviolet endonuclease. All cell lines were proficient in repair of ultraviolet and acetoxy acetylaminofluorene damage and at saturation doses of both agents repair was additive. We interpret these data as indicating that the rate limiting step in excision repair of ultraviolet and acetoxy acetylaminofluorene is different and that there are different enzyme(s) working on incision of both types of damages. (Auth.)

  8. Single scrotal incision orchidopexy for palpable undescended

    International Nuclear Information System (INIS)

    Ahmad, A.; Safdar, C.A.; Yasir, U.; Rasool, N.; Kanwal, S.; Boota, M.; Rehman, J.U.

    2014-01-01

    To retrospectively asses the results of single scrotal incision orchidopexy (SSIO) performed at our centre with ligation of the patent processus vaginalis in children having palpable undescended testes (UDT). Study Design: Quasi-experimental with retrospective data. Place and Duration of Study: Department of Paediatric surgery Military Hospital Rawalpindi, from April 2007 to December 2011. Patients and Methods: After making a single transverse incision at superior scrotal border, the testis was identified; gubernaculums and the sac were dissected to the highest level and divided. The testis was placed into the scrotum and fixed to the scrotal fascia/skin. All patients were assessed at 2 weeks, 2 months and 6 months post operatively, and then yearly. Results: A total of 38 orchidopexies were performed in 33 patients. The patients age ranged from 14 months to 7 years (mean:2.1 years). Bilateral UDT were found in 5 patients (15.1%). Operative time ranged from 20 to 45 minutes (mean: 36 minutes). The single scrotal incision technique was successful in all 38 cases (100%). All testes were easily fixed in the scrotum. Two patients (5.2%) developed scrotal haematoma and one patient (2.6%) developed stitch abscess. All showed good an atomical and cosmetic results up to a minimum of six months of follow-up. Conclusion: Single scrotal incision orchidopexy for palpable undescended testis is a simple and safe technique. It has shown to consume shorter time and give good cosmetic results. (author)

  9. Automatic determination of moisture content in biofuels based on NIR-measurements; Automatisk fukthaltsbestaemning av biobraenslen med NIR-metoden

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Magnus; Wiklund, Sven Erik [AaF-Process AB, Stockholm (Sweden); Karlsson, Mikael; Tryzell, Robert [Bestwood AB, Sundbyberg (Sweden)

    2005-07-01

    The determination of moisture content of biofuel is of large importance for the energy sector. The used methods for moisture determination are based on fuels samples taken from the bulk followed by drying and weighing. To be able to instead determine the moisture content based on a method with good accuracy and with a short response time would be a large improvement. Both for the fuel sampling and the following analysis there are Swedish standards but concerning the fuel sampling the standards are often not followed. The main reason is the difficulties to sample fuel samples from different depth from a delivery. This is one of the reasons that some plants have installed mechanical samplers but the investment cost for these is relatively high. The aim of this project was to investigate the use of the NIR-method for automatic moisture determination in biofuels. Within the project the NIR-method was used to determine the moisture content on withdrawn fuel samples, in addition the possibility to integrate the NIR-method in an automatic sampling system is also described. A large number of samples, in total over 200 samples, have been evaluated with the NIR-method and compared with the reference method, oven drying and gravimetric determination of moisture content. That the NIR-method can be used to determine moisture content in a number of well defined materials have previously been shown. In this report it has moreover been shown that the method can be used under the conditions at the fuel delivery station and for a large spectrum of biofuels. The accuracy that can be achieved with the NIR-method is in the same magnitude as the standard method, i.e. the reference method used for the measurements. Altogether this shows that the NIR-method is an interesting alternative for integration in an automatic measurement system for determination of fuel moisture content in biofuels. To be able to use the NIR-method for automatic determination of fuel moisture content at the

  10. Laparoscopic surgery for esophageal achalasia: Multiport vs single-incision approach.

    Science.gov (United States)

    Fukuda, Shuichi; Nakajima, Kiyokazu; Miyazaki, Yasuhiro; Takahashi, Tsuyoshi; Makino, Tomoki; Kurokawa, Yukinori; Yamasaki, Makoto; Miyata, Hiroshi; Takiguchi, Shuji; Mori, Masaki; Doki, Yuichiro

    2016-02-01

    SILS can potentially improve aesthetic outcomes without adversely affecting treatment outcomes, but these outcomes are uncertain in laparoscopic Heller-Dor surgery. We determined if the degree of patient satisfaction with aesthetic outcomes progressed with the equivalent treatment outcomes after the introduction of a single-incision approach to laparoscopic Heller-Dor surgery. We retrospectively reviewed 20 consecutive esophageal achalasia patients (multiport approach, n = 10; single-incision approach, n = 10) and assessed the treatment outcomes and patient satisfaction with the aesthetic outcomes. In the single-incision approach, thin supportive devices were routinely used to gain exposure to the esophageal hiatus. No statistically significant differences in the operating time (210.2 ± 28.8 vs 223.5 ± 46.3 min; P = 0.4503) or blood loss (14.0 ± 31.7 vs 16.0 ± 17.8 mL; P = 0.8637) were detected between the multiport and single-incision approaches. We experienced no intraoperative complications. Mild dysphagia, which resolved spontaneously, was noted postoperatively in one patient treated with the multiport approach. The reduction rate of the maximum lower esophageal sphincter pressure was 25.1 ± 34.4% for the multiport approach and 21.8 ± 19.2% for the single-incision approach (P = 0.8266). Patient satisfaction with aesthetic outcomes was greater for the single-incision approach than for the multiport approach. When single-incision laparoscopic Heller-Dor surgery was performed adequately and combined with the use of thin supportive devices, patient satisfaction with the aesthetic outcomes was higher and treatment outcomes were equivalent to those of the multiport approach. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  11. Small incision guarded hydroaspiration of iris lesions.

    Science.gov (United States)

    Singh, Arun D

    2017-11-01

    To describe the technique and results of a minimally invasive surgical technique for resection of small iris lesions. Consecutive case series of 22 patients with localised, small iris lesions that were resected using the described surgical technique that composed of multiple, small corneal incisions created to allow for internal iris resection with 23-gauge horizontal vitrectomy scissors, followed by guarded tumour aspiration through a clear plastic tubing (diameter 3.5 mm) primed with viscoelastic agent. The mean largest basal diameter was 3.0 mm (range 1.5-5.0 mm; median 3.0 mm) and mean thickness was 1.3 mm (range 0.5-2.5 mm; median 1.0 mm). Use of multiple (2-4) small corneal incisions (range 2.0-3.0 mm; mean 2.8 mm) allowed reduced postoperative morbidity (significant hyphema (0%), hypotony (0%), wound leak (0%), >2 line change in best corrected visual acuity at postoperative 1 week (4.5%) and mean corneal astigmatism of 1.0 D (range 0.14-2.99 D; median 0.8 D) at postoperative 4-12 weeks. The tumour could be resected with clear surgical margins in all neoplastic cases (benign (2), borderline (1) and malignant (16)). Local recurrence or metastases were not observed in any melanoma case over a mean follow-up of 33.0 months (range 1.0-90.0 months; median 33.5 months). Small incision guarded hydroaspiration is a minimally invasive surgical technique for resection of select small iris lesions. Use of multiple small corneal incisions avoids morbidity associated with a single large corneoscleral incision, and use of guarded aspiration may eliminate the risk of wound contamination by the malignant tumour. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Instrumentation and method for measuring NIR light absorbed in tissue during MR imaging in medical NIRS measurements

    Science.gov (United States)

    Myllylä, Teemu S.; Sorvoja, Hannu S. S.; Nikkinen, Juha; Tervonen, Osmo; Kiviniemi, Vesa; Myllylä, Risto A.

    2011-07-01

    Our goal is to provide a cost-effective method for examining human tissue, particularly the brain, by the simultaneous use of functional magnetic resonance imaging (fMRI) and near-infrared spectroscopy (NIRS). Due to its compatibility requirements, MRI poses a demanding challenge for NIRS measurements. This paper focuses particularly on presenting the instrumentation and a method for the non-invasive measurement of NIR light absorbed in human tissue during MR imaging. One practical method to avoid disturbances in MR imaging involves using long fibre bundles to enable conducting the measurements at some distance from the MRI scanner. This setup serves in fact a dual purpose, since also the NIRS device will be less disturbed by the MRI scanner. However, measurements based on long fibre bundles suffer from light attenuation. Furthermore, because one of our primary goals was to make the measuring method as cost-effective as possible, we used high-power light emitting diodes instead of more expensive lasers. The use of LEDs, however, limits the maximum output power which can be extracted to illuminate the tissue. To meet these requirements, we improved methods of emitting light sufficiently deep into tissue. We also show how to measure NIR light of a very small power level that scatters from the tissue in the MRI environment, which is characterized by strong electromagnetic interference. In this paper, we present the implemented instrumentation and measuring method and report on test measurements conducted during MRI scanning. These measurements were performed in MRI operating rooms housing 1.5 Tesla-strength closed MRI scanners (manufactured by GE) in the Dept. of Diagnostic Radiology at the Oulu University Hospital.

  13. Single incision laparoscopic cholecystectomy using the one-incision three-trocar technique with all straight instruments: how I do it?

    Institute of Scientific and Technical Information of China (English)

    Hongyi Cui

    2011-01-01

    Single incision laparoscopic surgery (SILS) is a novel minimally invasive surgical technique that is gaining popularity around the world.One of the most commonly performed procedures is single incision laparoscopic cholecystectomy (SILC).Most reported techniques utilize special purpose-made access port and articulating instruments,rendering the procedure costly and difficult to learn.This article provides a stepwise description of SILC technique using all straight instruments without the need for a special port.It aims to shorten the learning curve for surgeons wishing to adopt a safe and cost-effective SILC technique to their practice.

  14. Laser incising of wood: Impregnation of columns with water-soluble dye

    International Nuclear Information System (INIS)

    Hattori, N.; Ando, K.; Kitayama, S.; Nakamura, Y.

    1994-01-01

    To know whether or not laser incising is a useful pre-treatment technique in impregnating a chemical fluid into lumber, pin holes were made in columns of hinoki (Chamaecyparis obtusa Endl.), sugi (Cryptomeria japonica D. Don), karamatsu (Larix leptolepis Gordon) and douglas-fir (Pseudo-tsuga menziesii Franco) with 1.7 kW CO2 laser, and a water-soluble dye was impregnated into these columns with a local pressure impregnation device. Retentions, and lengths and widths of penetrations from each hole were measured quantitatively. Referring to the results of the preparatory experiment mentioned above, incising patterns for sugi and douglas-fir were designed, and the same water-soluble dye was impregnated into the laser-incised columns as well as into non-incised ones with the vacuum-pressure method to obtain penetrated layers with the target depths completely. As a result, a retention of 200 kg/m3 of dye could be achieved for a column of douglas-fir even if it is a species difficult to impregnate. The penetrated layer also could be formed completely at the depth of the laser incision. Therefore, it is concluded that laser incising can be used for the pre-treatment before impregnation of wood columns. (author)

  15. Estimation of Anthocyanin Content of Berries by NIR Method

    International Nuclear Information System (INIS)

    Zsivanovits, G.; Ludneva, D.; Iliev, A.

    2010-01-01

    Anthocyanin contents of fruits were estimated by VIS spectrophotometer and compared with spectra measured by NIR spectrophotometer (600-1100 nm step 10 nm). The aim was to find a relationship between NIR method and traditional spectrophotometric method. The testing protocol, using NIR, is easier, faster and non-destructive. NIR spectra were prepared in pairs, reflectance and transmittance. A modular spectrocomputer, realized on the basis of a monochromator and peripherals Bentham Instruments Ltd (GB) and a photometric camera created at Canning Research Institute, were used. An important feature of this camera is the possibility offered for a simultaneous measurement of both transmittance and reflectance with geometry patterns T0/180 and R0/45. The collected spectra were analyzed by CAMO Unscrambler 9.1 software, with PCA, PLS, PCR methods. Based on the analyzed spectra quality and quantity sensitive calibrations were prepared. The results showed that the NIR method allows measuring of the total anthocyanin content in fresh berry fruits or processed products without destroying them.

  16. Diathermy vs. scalpel skin incisions in general surgery: double-blind, randomized, clinical trial.

    Science.gov (United States)

    Shamim, Muhammad

    2009-08-01

    This prospective, double-blind, randomized, controlled trial was designed to compare the outcome of diathermy incisions versus scalpel incisions in general surgery. A total of 369 patients who underwent diathermy incision (group A: 185 patients) or scalpel incision (group B: 184 patients) were analyzed. Variables analyzed were: surgical wound classification, length and depth of incision, incision time, duration of operation, incisional blood loss, postoperative pain, duration of hospital stay, duration of healing, and postoperative complications. The inclusion criteria were all patients who underwent elective or emergency general surgery. The exclusion criteria were only cases with incomplete patients' data and patients who were lost to follow-up. This study was conducted at Fatima Hospital-Baqai Medical University and Shamsi Hospital (Karachi), from January 2006 to December 2007. Incision time was significantly longer for patients in group B (p = 0.001). Incisional blood loss also was more for patients in group B (p = 0.000). Pain perception was found to be markedly reduced during the first 48 h in group A (p = 0.000). Total period of hospital stay (p = 0.129) and time for complete wound healing (p = 0.683) were almost the same for both groups. Postoperative complication rate by wound classification did not differ markedly between the two groups (p = 0.002 vs. p = 0.000). Diathermy incision has significant advantages compared with the scalpel because of reduced incision time, less blood loss, & reduced early postoperative pain.

  17. NIR detects, destroys insect pests

    International Nuclear Information System (INIS)

    McGraw, L.C.

    1998-01-01

    What’s good for Georgia peanuts may also be good for Kansas wheat. An electric eye that scans all food-grade peanuts for visual defects could one day do the same for wheat kernels. For peanuts, it’s a proven method for monitoring quality. In wheat, scanning with near-infrared (NIR) energy can reveal hidden insect infestations that lower wheat quality. ARS entomologists James E. Throne and James E. Baker and ARS agricultural engineer Floyd E. Dowell are the first to combine NIR with an automated grain-handling system to rapidly detect insects hidden in single wheat kernels

  18. Channel incision and suspended sediment delivery at Caspar Creek, Mendocino County, California

    Science.gov (United States)

    Nicholas J. Dewey; Thomas E. Lisle; Leslie M. Reid

    2003-01-01

    Tributary and headwater valleys in the Caspar Creek watershed,in coastal Mendocino County, California,show signs of incision along much of their lengths.An episode of incision followed initial-entry logging which took place between 1860 and 1906. Another episode of incision cut into skid-trails created for second-entry logging in the 1970's.

  19. A study of incisive canal using a cone beam computed tomography

    International Nuclear Information System (INIS)

    Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Sang Rae

    2004-01-01

    To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70 kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. The mean length of incisive canal was 15.87 mm ± 2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm ± 0.76 and 3.89 mm ± 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3 ± 6.96 and 117.45 ± 7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r 0.258). This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  20. A study of incisive canal using a cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-03-15

    To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70 kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. The mean length of incisive canal was 15.87 mm {+-} 2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm {+-} 0.76 and 3.89 mm {+-} 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3 {+-} 6.96 and 117.45 {+-} 7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r 0.258). This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  1. A skin abscess model for teaching incision and drainage procedures.

    Science.gov (United States)

    Fitch, Michael T; Manthey, David E; McGinnis, Henderson D; Nicks, Bret A; Pariyadath, Manoj

    2008-07-03

    Skin and soft tissue infections are increasingly prevalent clinical problems, and it is important for health care practitioners to be well trained in how to treat skin abscesses. A realistic model of abscess incision and drainage will allow trainees to learn and practice this basic physician procedure. We developed a realistic model of skin abscess formation to demonstrate the technique of incision and drainage for educational purposes. The creation of this model is described in detail in this report. This model has been successfully used to develop and disseminate a multimedia video production for teaching this medical procedure. Clinical faculty and resident physicians find this model to be a realistic method for demonstrating abscess incision and drainage. This manuscript provides a detailed description of our model of abscess incision and drainage for medical education. Clinical educators can incorporate this model into skills labs or demonstrations for teaching this basic procedure.

  2. Standardization from a benchtop to a handheld NIR spectrometer using mathematically mixed NIR spectra to determine fuel quality parameters

    DEFF Research Database (Denmark)

    da Silva, Neirivaldo Cavalcante; Cavalcanti, Claudia Jessica; Honorato, Fernanda Araujo

    2017-01-01

    spectral responses of fuel samples (gasoline and biodiesel blends) from a high-resolution benchtop Frontier FT-NIR (PerkinElmer) spectrometer and a handheld MicroNIR™1700 (JDSU). These virtual standards can be created by mathematically mixing spectra from the pure solvents present in gasoline or diesel...... to the handheld MicroNIR using virtual standards as transfer samples...

  3. A multistep damage recognition mechanism for global genomic nucleotide excision repair.

    Science.gov (United States)

    Sugasawa, K; Okamoto, T; Shimizu, Y; Masutani, C; Iwai, S; Hanaoka, F

    2001-03-01

    A mammalian nucleotide excision repair (NER) factor, the XPC-HR23B complex, can specifically bind to certain DNA lesions and initiate the cell-free repair reaction. Here we describe a detailed analysis of its binding specificity using various DNA substrates, each containing a single defined lesion. A highly sensitive gel mobility shift assay revealed that XPC-HR23B specifically binds a small bubble structure with or without damaged bases, whereas dual incision takes place only when damage is present in the bubble. This is evidence that damage recognition for NER is accomplished through at least two steps; XPC-HR23B first binds to a site that has a DNA helix distortion, and then the presence of injured bases is verified prior to dual incision. Cyclobutane pyrimidine dimers (CPDs) were hardly recognized by XPC-HR23B, suggesting that additional factors may be required for CPD recognition. Although the presence of mismatched bases opposite a CPD potentiated XPC-HR23B binding, probably due to enhancement of the helix distortion, cell-free excision of such compound lesions was much more efficient than expected from the observed affinity for XPC-HR23B. This also suggests that additional factors and steps are required for the recognition of some types of lesions. A multistep mechanism of this sort may provide a molecular basis for ensuring the high level of damage discrimination that is required for global genomic NER.

  4. Sensitivity of fNIRS to cognitive state and load

    Directory of Open Access Journals (Sweden)

    Frank Anthony Fishburn

    2014-02-01

    Full Text Available Functional near-infrared spectroscopy (fNIRS is an emerging low-cost noninvasive neuroimaging technique that measures cortical bloodflow. While fNIRS has gained interest as a potential alternative to fMRI for use with clinical and pediatric populations, it remains unclear whether fNIRS has the necessary sensitivity to serve as a replacement for fMRI. The present study set out to examine whether fNIRS has the sensitivity to detect linear changes in activation and functional connectivity in response to cognitive load, and functional connectivity changes when transitioning from a task-free resting state to a task. Sixteen young adult subjects were scanned with a continuous-wave fNIRS system during a 10-minute resting-state scan followed by a letter n-back task with three load conditions. Five optical probes were placed over frontal and parietal cortices, covering bilateral dorsolateral PFC (dlPFC, bilateral ventrolateral PFC (vlPFC, frontopolar cortex (FP, and bilateral parietal cortex. Activation was found to scale linearly with working memory load in bilateral prefrontal cortex. Functional connectivity increased with increasing n-back loads for fronto-parietal, interhemispheric dlPFC, and local connections. Functional connectivity differed between the resting state scan and the n-back scan, with fronto-parietal connectivity greater during the n-back, and interhemispheric vlPFC connectivity greater during rest. These results demonstrate that fNIRS is sensitive to both cognitive load and state, suggesting that fNIRS is well-suited to explore the full complement of neuroimaging research questions and will serve as a viable alternative to fMRI.

  5. NIRS inaugurated as IAEA Collaborating Centre. Its presence and function

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Watanabe, Naoyuki; Sakai, Kazuo; Kamada, Tadashi; Imai, Reiko; Fujibayashi, Yasuhisa; Nakane, Takeshi; Burkart, W.; Chhem, R.; Matsuura, Shojiro

    2010-01-01

    The feature article is the collection of documents commemorating the 2010 designation of National Institute of Radiological Sciences (NIRS) as one of International Atomic Energy Agency (IAEA) Collaborating Centres (CC) again, involving 4 introductory chapters containing 9 sections in total. The IAEA-CC concept, essentially for the 4-year project, started to globally give shape by designating 3 organizations in some countries in 2004, NIRS as a CC worked from 2006 and the present designation is the renewed one. There are 17 IAEA-CCs at present. The title of Chapter 1 of the article is the same as above title by NIRS President and of Chapter 2, ''IAEA-CC scheme'' by NIRS Senior Specialist/ professor of Gunma Pref. College of Health Sciences/ former IAEA staff. Chapter 3 entitled ''Research Development of Next Four Years in Three Collaboration Areas'', contains 3 topics of the very areas mainly responsible to the project, of biological effect and mechanism of low dose radiation by NIRS Director of Res. Center for Radiation Protection, IAEA-CC plan (radiotherapy) by the Director for Charged Particle Therapy, and IAEA-CC activity and research at Molecular Imaging Center by its Director. Chapter 4 entitled ''Expectation to NIRS'' contains four topics; Expectations for the reinforcement of collaboration with IAEA whose new priority is cancer control by the Japanese Ambassador Extraordinary and Plenipotentiary in Vienna; Welcoming NIRS to join IAEA-CC network (an interview with IAEA Deputy Director General and Head of Nuclear Sciences and Applications); Honoured to invite NIRS to establish a new partnership with IAEA (an interview with IAEA Director of Division of Human Health, Dept. of Nuclear Sciences and Applications); Expectation to NIRS in peaceful use of nuclear and radiation by President of the Nuclear Safety Research Association. (T.T.)

  6. Modification of the Nuss Procedure: The Single-incision Technique

    Directory of Open Access Journals (Sweden)

    Tetsushi Aizawa, MD

    2014-11-01

    Full Text Available Summary: The Nuss procedure is a prevalent minimally invasive surgery for pectus excavatum. Although the Nuss procedure has the advantage of leaving less obtrusive scars, the standard technique requires at least 3 skin incisions to insert several instruments. We experienced 7 cases of the modified Nuss procedure using a single incision during a 7-year period. To facilitate passing of the bar, a traction guide was created according to our unique method. There was no need for a bar stabilizer, and no severe intraoperative complications occurred. All patients exhibited satisfactory short-term results; however, 1 patient suffered from bar rotation and required repeat surgery for fixation. Two patients underwent bar removal via the same single incision without any difficulties.

  7. Superficial parotidectomy via facelift incision

    NARCIS (Netherlands)

    Lohuis, Peter J. F. M.; Tan, M. Liane; Bonte, Katrien; van den Brekel, Michiel W. M.; Balm, Alfons J. M.; Vermeersch, Hubert B.

    2009-01-01

    The stigma of a visually prominent facial scar following parotid surgery can be distressing to a young patient. The surgical technique of parotidectomy via a facelift incision is described and evaluated. Thirty patients with a benign lesion of the parotid gland underwent a partial superficial

  8. De Qeurvian Tenosynovitis: Clinical Outcomes of Surgical Treatment with Longitudinal and Transverse Incision

    Directory of Open Access Journals (Sweden)

    Arefah Dehghani Tafti

    2011-03-01

    Full Text Available AbstractObjectives: De Quervain disease is a mechanical tenosynovitis due to inadequacy volume between abductor pollicis longus, extensor pollicis brevis and their tunnel. Treatment methods include immobilization, steroid injections, and operation. For the first time Fritz De Quervain described surgical treatment of this disease. Since then, various ways of treatment have been reported. The purpose of this study is to compare the clinical outcomes of a longitudinal incision with a transverse incision in De Quervain disease.Methods: This was a randomized controlled clinical trial conducted in three hospitals in Iran, Yazd from March 2003 to September 2008. One hundred-twenty patients with De Quervain disease who did not respond to conservative treatment were operated with two different incisions. The patients were followed for three months to compare the surgical outcomes.Results: During a three month follow-up, a significant difference was shown between the two methods (p=0.03. Results of surgical treatment with longitudinal incision were excellent (only 5 hypertrophic scars, but there were 13 postoperative complaints with transverse incision.Conclusion: According to our findings, longitudinal incision in surgical treatment of De Quervain disease is better than transverse incision.

  9. Brain Functional Connectivity in MS: An EEG-NIRS Study

    Science.gov (United States)

    2015-10-01

    1 AWARD NUMBER: W81XWH-14-1-0582 TITLE: Brain Functional Connectivity in MS: An EEG -NIRS Study PRINCIPAL INVESTIGATOR: Heather Wishart...Functional Connectivity in MS: An EEG -NIRS Study 5b. GRANT NUMBER W81XWH-14-1-0582 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER Heather...electrical ( EEG ) and blood volume and blood oxygen-based (NIRS and fMRI) signals, and to use the results to help optimize blood oxygen level

  10. Repair of acute injuries of the lateral ligament complex of the ankle by suture anchors

    Science.gov (United States)

    Liu, Xiang-Fei; Fang, Yang; Cao, Zhong-Hua; Li, Guang-Feng; Yang, Guo-Qing

    2015-01-01

    Objective: The objective of this study was to investigate the clinical curative effect of stage I repair of acute injuries of the lateral ligament complex of the ankle by the application of suture anchors. Methods: We retrospectively analyzed 18 cases of III degree acute injuries of the lateral ligament complex of the ankle. Results: There were statistically significant differences in preoperative and last follow-up VAS pain scores and AOFAS ankle hind-foot function scores. The X-ray talus displacement values in the anterior drawer test and pressure anteroposterior X-ray talar tilt in the ankle talar tilt test also showed statistically significant differences. Complications occurred in 2 patients, incision surface infection in one, and postoperative lateral dorsal skin numbness in one. All these cases were cured after symptomatic treatment. At the last follow-up all patients’ ankle joint activity recovered to their preinjury function levels. Conclusion: The application of suture anchors for small incision stage I repair of the lateral collateral ligament of ankle joint degree III injury, can effectively restored the stability of ankle joint, and prevent the occurrence of chronic ankle instability complications. It is effective and feasible for the treatment of ankle joint lateral collateral ligament injuries. PMID:26885144

  11. Does pilonidal abscess heal quicker with off-midline incision and drainage?

    Science.gov (United States)

    Webb, P M; Wysocki, A P

    2011-06-01

    No clinical trials have been done to guide the surgeon in the optimal technique of draining a pilonidal abscess. The aim of our study was to investigate whether the location of the incision influences wound healing. Electronic records from the surgical database at our 200-bed district general hospital were reviewed for operative technique (midline vs. lateral) for patients who underwent incision and drainage for acute pilonidal abscess between January 2003 and February 2010. These patients were admitted from the Emergency Department with a pilonidal abscess, underwent operative drainage, and returned for follow-up. The main outcome measure was wound healing time. Two hundred and forty-three pilonidal abscesses were drained, 134 with a lateral and 74 with a midline incision. All patients underwent simple longitudinal incision. No patient underwent de-roofing, marsupialisation, or closure. Forty-eight patients with midline drainage who returned for follow-up were matched for gender, age, and microbiology culture results with patients who underwent lateral drainage. Almost all were drained under general anesthesia with a median postoperative stay of 1 day. The overall length of follow-up was the same in both groups (P = 0.13). Abscesses that did not heal were followed-up for the same period of time irrespective of incision type (P = 0.48). Abscesses that healed after midline incision took approximately 3 weeks longer than those drained via a lateral incision (P = 0.02). Our study has limitations since it was a retrospective study that did not capture patients whose abscess drained spontaneously or were drained in the emergency department. Pilonidal abscess should be drained away from the midline.

  12. Towards NIRS-based hand movement recognition.

    Science.gov (United States)

    Paleari, Marco; Luciani, Riccardo; Ariano, Paolo

    2017-07-01

    This work reports on preliminary results about on hand movement recognition with Near InfraRed Spectroscopy (NIRS) and surface ElectroMyoGraphy (sEMG). Either basing on physical contact (touchscreens, data-gloves, etc.), vision techniques (Microsoft Kinect, Sony PlayStation Move, etc.), or other modalities, hand movement recognition is a pervasive function in today environment and it is at the base of many gaming, social, and medical applications. Albeit, in recent years, the use of muscle information extracted by sEMG has spread out from the medical applications to contaminate the consumer world, this technique still falls short when dealing with movements of the hand. We tested NIRS as a technique to get another point of view on the muscle phenomena and proved that, within a specific movements selection, NIRS can be used to recognize movements and return information regarding muscles at different depths. Furthermore, we propose here three different multimodal movement recognition approaches and compare their performances.

  13. Systematic review and meta-analysis of electrocautery versus scalpel for surgical skin incisions.

    Science.gov (United States)

    Aird, Lisa N F; Brown, Carl J

    2012-08-01

    The creation of surgical skin incisions has historically been performed using a cold scalpel. The use of electrocautery for this purpose has been controversial with respect to patient safety and surgical efficacy. A systematic review and meta-analysis of randomized controlled trials (RCTs) was conducted to compare skin incisions made by electrocautery and a scalpel. A systematic electronic literature search was performed using 2 electronic databases (MEDLINE and PubMed), and the methodological quality of included publications was evaluated. Six RCTs were identified comparing electrocautery (n = 606) and a scalpel (n = 628) for skin incisions. No significant difference in wound infection rates or scar cosmesis was identified between the treatment groups. Electrocautery significantly reduced the incision time and postoperative wound pain. A trend toward less incisional blood loss from skin incisions made with electrocautery was noted. Electrocautery is a safe and effective method for performing surgical skin incisions. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Thermal study of bare tips with various system parameters and incision sizes.

    Science.gov (United States)

    Osher, Robert H; Injev, Valentine P

    2006-05-01

    To identify major and minor surgeon-controlled parameters that affect incision temperature when performing microincision lens removal using the Alcon Infiniti Vision System. In vitro research and development laboratory, Alcon Research, Irvine, California, USA. Phacoemulsification was performed in eye-bank cadaver eyes and the following parameters evaluated: incision, duty cycle, ultrasound (US) power, aspiration flow rate (AFR), vacuum, pulse, bottle height and balanced salt solution temperature, and tip design/size. Each parameter was varied while the others remained constant. The resulting temperature of the incision and US tip was measured using a thermal camera. Major contributors to elevated incision temperature included incision size, US power, duty cycle, AFR, vacuum setting, tip design, and presence of an ophthalmic viscosurgical device (OVD). Minor contributors included pulse frequency, bottle height, and temperature of the infusate. Microincision lens removal can be performed at safe temperatures with the knowledgeable selection of surgeon-controlled parameters.

  15. Mesh Plug Repair of Inguinal Hernia; Single Surgeon Experience

    Directory of Open Access Journals (Sweden)

    Ahmet Serdar Karaca

    2013-10-01

    Full Text Available Aim: Mesh repair of inguinal hernia repairs are shown to be an effective and reliable method. In this study, a single surgeon%u2019s experience with plug-mesh method performs inguinal hernia repair have been reported. Material and Method: 587 patients with plug-mesh repair of inguinal hernia, preoperative age, body / mass index, comorbid disease were recorded in terms of form. All of the patients during the preoperative and postoperative hernia classification of information, duration of operation, antibiotics, perioperative complications, and later, the early and late postoperative complications, infection, recurrence rates and return to normal daily activity, verbal pain scales in terms of time and postoperative pain were evaluated. Added to this form of long-term pain ones. The presence of wound infection was assessed by the presence of purulent discharge from the incision. Visual analog scale pain status of the patients was measured. Results: 587 patients underwent repair of primary inguinal hernia mesh plug. One of the patients, 439 (74% of them have adapted follow-ups. Patients%u2019 ages ranged from 18-86. Was calculated as the mean of 47±18:07. Follow-up period of the patients was found to be a minimum of 3 months, maximum 55 months. Found an average of 28.2±13.4 months. Mean duration of surgery was 35.07±4.00 min (min:22mn-max:52mn, respectively. When complication rates of patients with recurrence in 2 patients (0.5%, hematoma development (1.4% in 6 patients, the development of infection in 11 patients (2.5% and long-term groin pain in 4 patients (0.9% appeared. Discussion: In our experience, the plug-mesh repair of primary inguinal hernia repair safe, effective low recurrence and complication rates can be used.

  16. Liposomal Bupivacaine During Robotic Colpopexy and Posterior Repair: A Randomized Controlled Trial.

    Science.gov (United States)

    Yeung, Jennifer; Crisp, Catrina C; Mazloomdoost, Donna; Kleeman, Steven D; Pauls, Rachel N

    2018-01-01

    To evaluate the effect of liposomal bupivacaine on postoperative pain among patients undergoing robotic sacrocolpopexy with posterior repair. This was a randomized, patient-blinded, placebo-controlled trial of women undergoing robotic sacrocolpopexy with posterior repair. Liposomal bupivacaine or normal saline placebo was injected into laparoscopic and vaginal incisions at completion of surgery. Perioperative care was standardized. Visual analog scales were collected at 4, 18, and 24 hours postoperatively in hospital. Starting on postoperative day 1, participants completed twice-daily pain scales and a pain medication diary up until the evening of postoperative day 3. The primary outcome was a 20-mm change in the visual analog scale 18 hours postoperatively. Secondary measures included additional pain scores, satisfaction, and narcotic use. Sample size calculation revealed that 32 patients per arm were required to detect the 20-mm difference with 90% power and an α of 0.05. To allocate for dropout, a goal of 70 was set. Between March 2015 and April 2016, 100 women were screened and 70 women were enrolled: 35 women were randomized to liposomal bupivacaine and 35 to placebo, of whom 64 (91%) were included in the final analysis: 33 liposomal bupivacaine and 31 placebo. No difference in demographics, surgical data, or satisfaction between groups was noted. Median VAS at 18 hours after surgery was not statistically different in those who received liposomal bupivacaine compared with normal saline (15 mm compared with 20 mm; P=.52). Other pain scales and total morphine equivalents were also similar (P=.90). In this study of robotic sacrocolpopexy with posterior repair, there were no differences in pain scores or narcotic use between liposomal bupivacaine and placebo injected into laparoscopic and vaginal incisions. Given its lack of clinical benefit, routine use of liposomal bupivacaine is not supported for this surgical intervention. ClinicalTrials.gov, NCT02449915.

  17. Minimizing surgical skin incision scars with a latex surgical glove.

    Science.gov (United States)

    Han, So-Eun; Ryoo, Suk-Tae; Lim, So Young; Pyon, Jai-Kyung; Bang, Sa-Ik; Oh, Kap-Sung; Mun, Goo-Hyun

    2013-04-01

    The current trend in minimally invasive surgery is to make a small surgical incision. However, the excessive tensile stress applied by the retractors to the skin surrounding the incision often results in a long wound healing time and extensive scarring. To minimize these types of wound problems, the authors evaluated a simple and cost-effective method to minimize surgical incision scars based on the use of a latex surgical glove. The tunnel-shaped part of a powder-free latex surgical glove was applied to the incision and the dissection plane. It was fixed to the full layer of the dissection plane with sutures. The glove on the skin surface then was sealed with Ioban (3 M Health Care, St. Paul, MN, USA) to prevent movement. The operation proceeded as usual, with the retractor running through the tunnel of the latex glove. It was possible to complete the operation without any disturbance of the visual field by the surgical glove, and the glove was neither torn nor separated by the retractors. The retractors caused traction and friction during the operation, but the extent of damage to the postoperative skin incision margin was remarkably less than when the operation was performed without a glove. This simple and cost-effective method is based on the use of a latex surgical glove to protect the surgical skin incision site and improve the appearance of the postoperative scar. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  18. Modified tubularized incised plate urethroplasty

    Directory of Open Access Journals (Sweden)

    Shivaji Mane

    2013-01-01

    Full Text Available Aim: To share our experience of doing tubularized incised plate urethroplasty with modifications. Materials and Methods: This is a single surgeon personal series from 2004 to 2009. One hundred patients of distal hypospadias were subjected for Snodgrass urethroplasty with preputioplasty. The age range was 1 to 5 year with mean age of 2.7 years. Selection criteria were good urethral plate, without chordee and torsion needing complete degloving. Main technical modification from original Snodgrass procedure was spongioplasty, preputioplasty, and dorsal slit when inability to retract prepuce during surgery. Results: Average follow-up period is 23 months. Seven (7% patients developed fistula and one patient had complete preputial dehiscence. Phimosis developed in three (3% patients and required circumcision. Dorsal slit was required in seven patients. One patient developed meatal stenosis in postoperative period. All other patients are passing single urinary stream and have cosmesis that is acceptable. Conclusions: Modified tubularized incised plate urethroplasty with preputioplasty effectively gives cosmetically normal looking penis with low complications.

  19. Penatalaksanaan Repair Palatoplasty dengan Teknik Furlow Double Opposing Z Plasty

    Directory of Open Access Journals (Sweden)

    Pingky Krisna Arindra

    2015-06-01

    metode Furlow double opposing z plasty dengan kombinasi insisi lateral, dan didapatkan hasil menutupnya celah di palatum mole sampai dengan uvula. Telah dilakukan operasi repair palatoplasi dengan metode Furlow double opposing z plasty. Teknik ini dilakukan untuk menghindari insisi yang terlalu luas dikarenakan terdapatnya jaringan fibrous yang tebal pada mukosa palatum pasca operasi sebelumnya. Tujuan studi kasus adalah untuk mengetahui kemampuan teknik Furlow Double Opposing Z Plasty sebagai prosedur repair palatoplasty.   Repair Palatoplasty Management with Furlow Double Opposing Z Plasty Technique. Cases of cleft lip and palate are one of the deformity disorders that often occur. There are variety of clinical appearance ranging from incomplete to complete cases. Clinical appearance with different width requires proper surgical technique. Patients with cleft lip and palate had undergone surgical intervention, so that they needed surgical correction to repair the result or failure of the previous surgery. A Four year old boy complain there was cleft on the soft palate. The patient was diagnosed with labiognatopalatoscisis. The patient had undergone two stages of cleft lip surgery and twice of cleft palate surgery with pushback method and repair with z plasty, however the result was unsatisfactory. Further, the patient underwent repair palatoplasty surgery with Furlow double opposing z plasty method combined with lateral relaxing insicion. The result in the post surgery was the closure of cleft soft palate up to uvula. Repair palataplasty surgery has been done with Furlow double opposing z plasty method. This technique could avoid extended incision due to thick fibrous tissue on the palatum mucosa as the result of serial previous surgery. The aim of this case case study is to determine the technical capabilities of Furlow Double Opposing Z Plasty as palatoplasty repair procedure.

  20. Cochlear implantation with Pulsar Med El: a novel small incision technique.

    Science.gov (United States)

    Cuda, D

    2009-04-01

    Although still widely implanted, Pulsar Med-El is rarely considered for small incision approach. Overall, 30 teen-age and adult patients were operated upon with a novel small incision (4-5 cm). Full insertion of the electrode array was achieved in all cases. No major intra-operative complications occurred. At follow-up, no flap-related complications and no migration of the receiver-stimulator were observed in the "device suture" (14 patients) or "no device suture" groups (16 patients). All patients are full-time users of the device. In conclusion, a small incision for the Pulsar Med-El cochlear implant is feasible, safe and reproducible. Ligature fixation of the device is not critical with this operation. Also with this device, in adult and teen-age patients, it is, therefore, possible to retain several typical advantages of small incision approaches.

  1. The effect of platelet rich fibrin on growth factor levels in urethral repair.

    Science.gov (United States)

    Soyer, Tutku; Ayva, Şebnem; Boybeyi, Özlem; Aslan, Mustafa Kemal; Çakmak, Murat

    2013-12-01

    Platelet rich fibrin (PRF) is an autologous source of growth factors and promotes wound healing. An experimental study was performed to evaluate the effect of PRF on growth factor levels in urethral repair. Eighteen Wistar albino rats were included in the study. Rats were allocated in three groups (n:6): control (CG), sham (SG), and PRF (PRFG). In SG, a 5 mm vertical incision was performed in the penile urethra and repaired with 10/0 Vicryl® under a microscope. In PRFG, during the urethral repair as described in SG, 1 cc of blood was sampled from each rat and centrifuged for 10 minutes at 2400 rpm. PRF obtained from the centrifugation was placed on the repair site during closure. Penile urethras were sampled 24 hours after PRF application in PRFG and after urethral repair in SG. Transforming growth factor beta receptor (TGF-β-R-CD105), vascular endothelial growth factor (VEGF) and its receptor (VEGF-R), as well as endothelial growth factor receptor (EGFR), were evaluated in subepithelia of the penile skin and urethra. Groups were compared for growth factor levels and growth factor receptor expression with the Kruskal Wallis test. TGF-β-R levels were significantly decreased in SG when compared to CG (p0.05). Use of PRF after urethral repair increases TGF-β-R and VEGF expressions in urethral tissue. PRF can be considered as an alternative measure to improve the success of urethral repair. © 2013.

  2. Clinical Outcomes and Complications of Percutaneous Achilles Repair System Versus Open Technique for Acute Achilles Tendon Ruptures.

    Science.gov (United States)

    Hsu, Andrew R; Jones, Carroll P; Cohen, Bruce E; Davis, W Hodges; Ellington, J Kent; Anderson, Robert B

    2015-11-01

    Limited incision techniques for acute Achilles tendon ruptures have been developed in recent years to improve recovery and reduce postoperative complications compared with traditional open repair. The purpose of this retrospective cohort study was to analyze the clinical outcomes and postoperative complications between acute Achilles tendon ruptures treated using a percutaneous Achilles repair system (PARS [Arthrex, Inc, Naples, FL]) versus open repair and evaluate the overall outcomes for operatively treated Achilles ruptures. Between 2005 and 2014, 270 consecutive cases of operatively treated acute Achilles tendon ruptures were reviewed (101 PARS, 169 open). Patients with Achilles tendinopathy, insertional ruptures, chronic tears, or less than 3-month follow-up were excluded. Operative treatment consisted of a percutaneous technique (PARS) using a 2-cm transverse incision with FiberWire (Arthrex, Inc, Naples, FL) sutures or open repair using a 5- to 8-cm posteromedial incision with FiberWire in a Krackow fashion reinforced with absorbable sutures. Patient demographics were recorded along with medical comorbidities, activity at injury, time from injury to surgery, length of follow-up, return to baseline activities by 5 months, and postoperative complications. The most common activity during injury for both groups was basketball (PARS: 39%, open: 47%). A greater number of patients treated with PARS were able to return to baseline physical activities by 5 months compared with the open group (PARS: 98%, open: 82%; P = .0001). There were no significant differences (P > .05) between groups in rates of rerupture (P = 1.0), sural neuritis (P = .16), wound dehiscence (P = .74), superficial (P = .29) and/or deep infection (P = .29), or reoperation (P = .13). There were no deep vein thromboses (DVTs) or reruptures in either group. In the PARS group, there were no cases of sural neuritis, 3 cases (3%) of superficial wound dehiscence, and 2 reoperations (2%) for superficial

  3. Effects of post mortem interval and gender in DNA base excision repair activities in rat brains

    Energy Technology Data Exchange (ETDEWEB)

    Soltys, Daniela Tathiana; Pereira, Carolina Parga Martins; Ishibe, Gabriela Naomi; Souza-Pinto, Nadja Cristhina de, E-mail: nadja@iq.usp.br

    2015-06-15

    Most human tissues used in research are of post mortem origin. This is the case for all brain samples, and due to the difficulty in obtaining a good number of samples, especially in the case of neurodegenerative diseases, male and female samples are often included in the same experimental group. However, the effects of post mortem interval (PMI) and gender differences in the endpoints being analyzed are not always fully understood, as is the case for DNA repair activities. To investigate these effects, in a controlled genetic background, base excision repair (BER) activities were measured in protein extracts obtained from Wistar rat brains from different genders and defined PMI up to 24 hours, using a novel fluorescent-based in vitro incision assay. Uracil and AP-site incision activity in nuclear and mitochondrial extracts were similar in all groups included in this study. Our results show that gender and PMI up to 24 hours have no influence in the activities of the BER proteins UDG and APE1 in rat brains. These findings demonstrate that these variables do not interfere on the BER activities included in these study, and provide a security window to work with UDG and APE1 proteins in samples of post mortem origin.

  4. Effects of post mortem interval and gender in DNA base excision repair activities in rat brains

    International Nuclear Information System (INIS)

    Soltys, Daniela Tathiana; Pereira, Carolina Parga Martins; Ishibe, Gabriela Naomi; Souza-Pinto, Nadja Cristhina de

    2015-01-01

    Most human tissues used in research are of post mortem origin. This is the case for all brain samples, and due to the difficulty in obtaining a good number of samples, especially in the case of neurodegenerative diseases, male and female samples are often included in the same experimental group. However, the effects of post mortem interval (PMI) and gender differences in the endpoints being analyzed are not always fully understood, as is the case for DNA repair activities. To investigate these effects, in a controlled genetic background, base excision repair (BER) activities were measured in protein extracts obtained from Wistar rat brains from different genders and defined PMI up to 24 hours, using a novel fluorescent-based in vitro incision assay. Uracil and AP-site incision activity in nuclear and mitochondrial extracts were similar in all groups included in this study. Our results show that gender and PMI up to 24 hours have no influence in the activities of the BER proteins UDG and APE1 in rat brains. These findings demonstrate that these variables do not interfere on the BER activities included in these study, and provide a security window to work with UDG and APE1 proteins in samples of post mortem origin

  5. NIRS Characterization of Paper Pulps to Predict Kappa Number

    Directory of Open Access Journals (Sweden)

    Ana Moral

    2015-01-01

    Full Text Available Rice is one of the most abundant food crops in the world and its straw stands as an important source of fibres both from an economic and an environmental point of view. Pulp characterization is of special relevance in works involving alternative raw materials, since pulp properties are closely linked to the quality of the final product. One of the analytical techniques that can be used in pulp characterization is near-infrared spectroscopy (NIRS. The use of NIRS has economic and technical advantages over conventional techniques. This paper aims to discuss the convenience of using NIRS to predict Kappa number in rice straw pulps produced under different conditions. We found that the resulting Kappa number can be acceptably estimated by NIRS, as the errors obtained with that method are similar to those found for other techniques.

  6. fNIRS-based brain-computer interfaces: a review

    Directory of Open Access Journals (Sweden)

    Noman eNaseer

    2015-01-01

    Full Text Available A brain-computer interface (BCI is a communication system that allows the use of brain activity to control computers or other external devices. It can, by bypassing the peripheral nervous system, provide a means of communication for people suffering from severe motor disabilities or in a persistent vegetative state. In this paper, brain-signal generation tasks, noise removal methods, feature extraction/selection schemes, and classification techniques for fNIRS-based BCI are reviewed. The most common brain areas for fNIRS BCI are the primary motor cortex and the prefrontal cortex. In relation to the motor cortex, motor imagery tasks were preferred to motor execution tasks since possible proprioceptive feedback could be avoided. In relation to the prefrontal cortex, fNIRS showed a significant advantage due to no hair in detecting the cognitive tasks like mental arithmetic, music imagery, emotion induction, etc. In removing physiological noise in fNIRS data, band-pass filtering was mostly used. However, more advanced techniques like adaptive filtering, independent component analysis, multi optodes arrangement, etc. are being pursued to overcome the problem that a band-pass filter cannot be used when both brain and physiological signals occur within a close band. In extracting features related to the desired brain signal, the mean, variance, peak value, slope, skewness, and kurtosis of the noised-removed hemodynamic response were used. For classification, the linear discriminant analysis method provided simple but good performance among others: support vector machine, hidden Markov model, artificial neural network, etc. fNIRS will be more widely used to monitor the occurrence of neuro-plasticity after neuro-rehabilitation and neuro-stimulation. Technical breakthroughs in the future are expected via bundled-type probes, hybrid EEG-fNIRS BCI, and through the detection of initial dips.

  7. Mouse preferential incising force orientation changes during jaw closing muscle hyperalgesia and is sex dependent.

    Science.gov (United States)

    Widmer, C G; Morris-Wiman, J

    2016-12-01

    Mouse incising is controlled by a central pattern generator and this activity can change in the presence of pain. The incising frequency and maximum force generation decreases with pain. In this study, we used repetitive acidic injections in the left masseter muscle of male and female mice to determine differences between baseline and jaw muscle pain conditions and the effect of sex on preferential incising direction. A within subject design was used to evaluate data previously acquired using multi-axis force data (X, Y and Z) from the 4th baseline recording day and day 7 post-injection (day of maximal pain response) for each mouse of each sex. A total of 34 female and male (age 3-9months) CD-1 mice were evaluated. After mathematically rotating the X and Y axes to align the Y axis to be parallel to the wire struts of the cage top, data were analyzed to determine incising direction preference during baseline (non-pain) and pain (day 7) conditions and between sex. Radar plots of X-Y, X-Z and Y-Z axes depicted the average direction of incising preference between baseline and pain conditions for each sex. Statistical differences among groups were tested using a mixed model ANOVA. Similar to previous findings, female mice had a more robust difference in incising direction preference when comparing male and female pain conditions and this was most evident in the X-Z axes. The incising frequencies most commonly affected were 5.3, 6.2 and 7.6Hz. Male mice varied little in their incising direction preference between the baseline and pain conditions. In addition, statistical comparison of ratios of the percent of time spent incising in the Z versus X axes for each incising frequency found that the incising preference was not different when comparing 5.3 and 7.6Hz frequencies. Finally, female mice used a novel approach to minimize pain while incising by rotating their head and body nearly 180 degrees while males did not use this strategy as frequently. The preferred incising

  8. The Fanconi anemia pathway promotes replication-dependent DNA interstrand cross-link repair.

    Science.gov (United States)

    Knipscheer, Puck; Räschle, Markus; Smogorzewska, Agata; Enoiu, Milica; Ho, The Vinh; Schärer, Orlando D; Elledge, Stephen J; Walter, Johannes C

    2009-12-18

    Fanconi anemia is a human cancer predisposition syndrome caused by mutations in 13 Fanc genes. The disorder is characterized by genomic instability and cellular hypersensitivity to chemicals that generate DNA interstrand cross-links (ICLs). A central event in the activation of the Fanconi anemia pathway is the mono-ubiquitylation of the FANCI-FANCD2 complex, but how this complex confers ICL resistance remains enigmatic. Using a cell-free system, we showed that FANCI-FANCD2 is required for replication-coupled ICL repair in S phase. Removal of FANCD2 from extracts inhibits both nucleolytic incisions near the ICL and translesion DNA synthesis past the lesion. Reversal of these defects requires ubiquitylated FANCI-FANCD2. Our results show that multiple steps of the essential S-phase ICL repair mechanism fail when the Fanconi anemia pathway is compromised.

  9. Relaxation incisions of venomous snake "Japanese mamushi" bites to the hand

    Directory of Open Access Journals (Sweden)

    Sugamata A

    2011-12-01

    Full Text Available Akira Sugamata, Naoki Yoshizawa, Takahiro OkadaDepartment of Plastic and Reconstructive Surgery, Tokyo Medical University Hachioji Medical Center, Tokyo, JapanAbstract: Gloydius blomhoffii, commonly known as Japanese mamushi, is a venomous viper species found widely in Japan. The most frequently bitten regions are the fingers and toes, and severe swelling causes compression of peripheral arteries and/or compartment syndrome of the extremities. We experienced four cases of mamushi bites to the hand, and undertook relaxation incision in the hands of three of these patients. As a result, the patients who underwent relaxation incision did not show any skin necrosis or permanent sensory disturbance in the affected fingers. Relaxation incision can be useful to not only decompress subcutaneous and compartment pressure of the hand, but also to wash out the venom from the bitten region by improving venous and lymphatic drainage.Keywords: mamushi, snakebite, viper, relaxation incision

  10. Towards achieving small-incision cataract surgery 99.8% of the time.

    Directory of Open Access Journals (Sweden)

    Thomas R

    2000-01-01

    Full Text Available A surgical approach designed to reliably attain the modern goal of small incision cataract surgery 99.8% of the time is described. Phacoemulsification as well as a manual small incision technique is utilised to achieve the desired outcome as often as possible and for all types of cataracts. The logic, and required surgical steps are described and illustrated. This surgical technique allows the advantages of small incision surgery to be reliably achieved. The method is flexible and allows decisions and steps to be modified depending on the skill and comfort zone of the individual surgeon.

  11. Circumareolar incision-subdermal tunneling dissection for excision of multiple breast fibroadenomata

    Directory of Open Access Journals (Sweden)

    S O Agodirin

    2017-01-01

    Full Text Available Excision of multiple fibroadenomas (MF in separate breast quadrants presents difficulties of number and location of incision(s and extent of tissue dissection and may be associated with more complications and poorer cosmetic outcome. This is a report of excision of MF in multiple quadrants of the breast using a modification of subcutaneous dissection technique dubbed the circumareolar incision and subdermal tunneling (CAST dissection. After exposure of the superficial fascia with circumareolar incision, subdermal cone-wise dissection was made to allow mobilization of the segment bearing the lump(s. The lump(s were enucleated and removed. MF were removed from four breasts in three young unmarried females. The first patient had multiple adenomas removed from three quadrants of both breasts: 14 on the right and six on the left. The second patient had excision of three lumps in three separate quadrants, and the third patient had excision of two lumps in two separate quadrants. All patients had edema and bruising. One breast had wound infection and dehiscence. There were no skin necrosis, no nipple loss, and no breast distortion. All ensuing scars were camouflaged. CAST dissection was used for excision of MF in multiple quadrants of the breast with preservation of excellent cosmetic outcome of a single circumareolar incision.

  12. Correlations between in situ denitrification activity and nir-gene abundances in pristine and impacted prairie streams

    International Nuclear Information System (INIS)

    Graham, David W.; Trippett, Clare; Dodds, Walter K.; O'Brien, Jonathan M.; Banner, Eric B.K.; Head, Ian M.; Smith, Marilyn S.; Yang, Richard K.; Knapp, Charles W.

    2010-01-01

    Denitrification is a process that reduces nitrogen levels in headwaters and other streams. We compared nirS and nirK abundances with the absolute rate of denitrification, the longitudinal coefficient of denitrification (i.e., K den , which represents optimal denitrification rates at given environmental conditions), and water quality in seven prairie streams to determine if nir-gene abundances explain denitrification activity. Previous work showed that absolute rates of denitrification correlate with nitrate levels; however, no correlation has been found for denitrification efficiency, which we hypothesise might be related to gene abundances. Water-column nitrate and soluble-reactive phosphorus levels significantly correlated with absolute rates of denitrification, but nir-gene abundances did not. However, nirS and nirK abundances significantly correlated with K den , as well as phosphorus, although no correlation was found between K den and nitrate. These data confirm that absolute denitrification rates are controlled by nitrate load, but intrinsic denitrification efficiency is linked to nirS and nirK gene abundances. - Denitrification efficiency best correlated to nirS and nirK gene abundances.

  13. NIR techniques create added values for the pellet and biofuel industry.

    Science.gov (United States)

    Lestander, Torbjörn A; Johnsson, Bo; Grothage, Morgan

    2009-02-01

    A 2(3)-factorial experiment was carried out in an industrial plant producing biofuel pellets with sawdust as feedstock. The aim was to use on-line near infrared (NIR) spectra from sawdust for real time predictions of moisture content, blends of sawdust and energy consumption of the pellet press. The factors varied were: drying temperature and wood powder dryness in binary blends of sawdust from Norway spruce and Scots pine. The main results were excellent NIR calibration models for on-line prediction of moisture content and binary blends of sawdust from the two species, but also for the novel finding that the consumption of electrical energy per unit pelletized biomass can be predicted by NIR reflectance spectra from sawdust entering the pellet press. This power consumption model, explaining 91.0% of the variation, indicated that NIR data contained information of the compression and friction properties of the biomass feedstock. The moisture content model was validated using a running NIR calibration model in the pellet plant. It is shown that the adjusted prediction error was 0.41% moisture content for grinded sawdust dried to ca. 6-12% moisture content. Further, although used drying temperatures influenced NIR spectra the models for drying temperature resulted in low prediction accuracy. The results show that on-line NIR can be used as an important tool in the monitoring and control of the pelletizing process and that the use of NIR technique in fuel pellet production has possibilities to better meet customer specifications, and therefore create added production values.

  14. Incision extension is the optimal method of difficult gallbladder extraction at laparoscopic cholecystectomy.

    Science.gov (United States)

    Bordelon, B M; Hobday, K A; Hunter, J G

    1992-01-01

    An unsolved problem of laparoscopic cholecystectomy is the optimal method of removing the gallbladder with thick walls and a large stone burden. Proposed solutions include fascial dilatation, stone crushing, and ultrasonic, high-speed rotary, or laser lithotripsy. Our observation was that extension of the fascial incision to remove the impacted gallbladder was time efficient and did not increase postoperative pain. We reviewed the narcotic requirements of 107 consecutive patients undergoing laparoscopic cholecystectomy. Fifty-two patients required extension of the umbilical incision, and 55 patients did not have their fascial incision enlarged. Parenteral meperidine use was 39.5 +/- 63.6 mg in the patients requiring fascial incision extension and 66.3 +/- 79.2 mg in those not requiring fascial incision extension (mean +/- standard deviation). Oral narcotic requirements were 1.1 +/- 1.5 doses vs 1.3 +/- 1.7 doses in patients with and without incision extension, respectively. The wide range of narcotic use in both groups makes these apparent differences not statistically significant. We conclude that protracted attempts at stone crushing or expensive stone fragmentation devices are unnecessary for the extraction of a difficult gallbladder during laparoscopic cholecystectomy.

  15. Transverse versus Longitudinal Incisions for Femoral Artery Exposure in Treating Patients with Peripheral Vascular Disease.

    Science.gov (United States)

    Parikh, Punam P; Rubio, Gustavo A; Patel, Kunal; Gupta, Kapil; Jones, Keith; Rey, Jorge; Robinson, Handel

    2018-02-01

    This study evaluates differences in wound complication rate when transverse versus longitudinal incision is utilized to expose femoral vessels in managing patients with peripheral vascular disease. A retrospective review from 2013 to 2015 was conducted of 150 patients undergoing 156 lower extremity revascularizations with femoral artery exposure through a groin incision. Patients were stratified into 2 groups, transverse versus longitudinal groin incision. Data were reviewed for 3 surgeons that utilize either transverse or longitudinal groin incision in patients undergoing common or iliofemoral endarterectomies, or where femoral artery was used as inflow and/or outflow vessel for limb revascularization. Each group had a comparative outcomes analysis based on incision type. The primary outcome was wound complication, defined as any wound infection, lymphocele, hematoma, dehiscence, pseudoaneurysm, or necrosis. Other outcomes studied included unplanned return to operating room for wound complication, wound vacuum therapy, and soft-tissue flap closure. Data were analyzed using 2-tailed chi-squared test and Student's t-test. Patients in the transverse (n = 85 cases) versus longitudinal (n = 71 cases) cohorts were similar in relation to demographics and comorbidities. Overall mean follow-up was 220 days. Patients with a transverse as compared to longitudinal incision had a significantly lower overall wound complication rate, 7% vs. 42%, respectively (P transverse incisions were associated with lower incidence of unplanned return to the operating room to manage wound complications than patients with a longitudinal incision (5% vs. 23%, respectively; P Transverse versus longitudinal incisions were also associated with significantly lower need for wound vacuum therapy (6% vs. 15%, respectively; P Transverse groin incisions for femoral artery exposure may offer a lower risk of wound complications for open procedures as compared to a longitudinal incision

  16. Inroads into base excision repair I. The discovery of apurinic/apyrimidinic (AP) endonuclease. "An endonuclease for depurinated DNA in Escherichia coli B," Canadian Journal of Biochemistry, 1972.

    Science.gov (United States)

    Lindahl, Tomas; Verly, W G; Paquette Y

    2004-11-02

    DNA treated with alkylating agents is incised at sites of damage by cell extracts. A key component of this DNA repair function was shown by Verly and co-workers to be an endonuclease acting at secondary lesions, apurinic sites, rather than directly at alkylated nucleotide residues.

  17. Discussion on the Relevant Factors of General Surgery Incision Infection and Prevention Methods

    Directory of Open Access Journals (Sweden)

    Jin Baotao

    2017-01-01

    Full Text Available There are many reasons that can lead to incision infection of general surgical patients. The main reasons include weight, age, body albumin level, surgical time, observation ward, etc. This paper analyzes the clinic data of patients with incision infection after general surgery based on clinic practice and study on the reasons that have impact on general surgical incision infection and gives relevant prevention countermeasures.

  18. Afroze incision for functional cheiloseptoplasty.

    NARCIS (Netherlands)

    Reddy, G.S.; Reddy, R.R.; Pagaria, N.; Berge, S.J.

    2009-01-01

    Repair of unilateral cleft lip is a fascinating and challenging procedure. Although a great number of operations have been described for the unilateral cleft lip repair, none fulfill all the plastic surgical criteria, and in most cases, cleft lip repairs require secondary operations in an attempt to

  19. A tetrad of bicuspid aortic valve association: A single-stage repair

    Science.gov (United States)

    Barik, Ramachandra; Patnaik, A. N.; Mishra, Ramesh C.; Kumari, N. Rama; Gulati, A. S.

    2012-01-01

    We report a 27 years old male who presented with a combination of both congenital and acquired cardiac defects. This syndrome complex includes congenital bicuspid aortic valve, Seller's grade II aortic regurgitation, juxta- subclavian coarctation, stenosis of ostium of left subclavian artery and ruptured sinus of Valsalva aneurysm without any evidence of infective endocarditis. This type of constellation is extremely rare. Neither coarctation of aorta with left subclavian artery stenosis nor the rupture of sinus Valsalva had a favorable pathology for percutaneus intervention. Taking account into morbidity associated with repeated surgery and anesthesia patient underwent a single stage surgical repair of both the defects by two surgical incisions. The approaches include median sternotomy for rupture of sinus of Valsalva and lateral thoracotomy for coarctation with left subclavian artery stenosis. The surgery was uneventful. After three months follow up echocardiography showed mild residual gradient across the repaired coarctation segment, mild aortic regurgitation and no residual left to right shunt. This patient is under follow up. This is an extremely rare case of single stage successful repair of coarctation and rupture of sinus of Valsalva associated with congenital bicuspid aortic valve. PMID:22629035

  20. Low risk of pulmonary valve implantation after a policy of transatrial repair of tetralogy of Fallot delayed beyond the neonatal period: the Melbourne experience over 25 years.

    Science.gov (United States)

    d'Udekem, Yves; Galati, John C; Rolley, Glenda J; Konstantinov, Igor E; Weintraub, Robert G; Grigg, Leeanne; Ramsay, James M; Wheaton, Gavin R; Hope, Sarah; Cheung, Michael H; Brizard, Christian P

    2014-02-18

    The study sought to evaluate the late outcomes of a policy of transatrial repair delayed beyond the neonatal period. Long-term outcomes of transatrial repair of tetralogy of Fallot are unknown. The records of 675 consecutive patients undergoing a transatrial repair of tetralogy of Fallot between 1980 and 2005 were reviewed, their follow-up updated and survival confirmed from national death registries. One-third (220 of 675) had undergone previous palliation. Median age at repair was 2 years in the first 8 years, and 1 year from 1988 onward. A transannular incision was performed in 75% of cases and autologous pericardium was the material used to patch this incision in 92% of cases. There were 7 hospital deaths (1%). Eight patients died during follow-up (2 sudden unexpected and 6 noncardiac deaths). Mean follow-up was 11.7 ± 6.3 years. Twenty-five years' survival was 97% (95% confidence interval [CI]: 95% to 98%). Twenty-five years' freedom from implantation of a valved conduit was 84.6% (95% CI: 77.8% to 89.5%). By multivariable analysis, prior palliation and younger age at repair were predictive of implantation of a valved conduit (hazard ratio: 2.4, 95% CI: 1.3 to 4.6, p = 0.008; hazard ratio: 0.70, 95% CI: 0.50 to 0.96, p = 0.03, respectively). During long-term follow-up, transatrial repair of tetralogy of Fallot was associated with a minimal risk of sudden death and low rate of reintervention for right ventricular dilation and residual outflow tract obstruction. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Comparing the analytical performances of Micro-NIR and FT-NIR spectrometers in the evaluation of acerola fruit quality, using PLS and SVM regression algorithms.

    Science.gov (United States)

    Malegori, Cristina; Nascimento Marques, Emanuel José; de Freitas, Sergio Tonetto; Pimentel, Maria Fernanda; Pasquini, Celio; Casiraghi, Ernestina

    2017-04-01

    The main goal of this study was to investigate the analytical performances of a state-of-the-art device, one of the smallest dispersion NIR spectrometers on the market (MicroNIR 1700), making a critical comparison with a benchtop FT-NIR spectrometer in the evaluation of the prediction accuracy. In particular, the aim of this study was to estimate in a non-destructive manner, titratable acidity and ascorbic acid content in acerola fruit during ripening, in a view of direct applicability in field of this new miniaturised handheld device. Acerola (Malpighia emarginata DC.) is a super-fruit characterised by a considerable amount of ascorbic acid, ranging from 1.0% to 4.5%. However, during ripening, acerola colour changes and the fruit may lose as much as half of its ascorbic acid content. Because the variability of chemical parameters followed a non-strictly linear profile, two different regression algorithms were compared: PLS and SVM. Regression models obtained with Micro-NIR spectra give better results using SVM algorithm, for both ascorbic acid and titratable acidity estimation. FT-NIR data give comparable results using both SVM and PLS algorithms, with lower errors for SVM regression. The prediction ability of the two instruments was statistically compared using the Passing-Bablok regression algorithm; the outcomes are critically discussed together with the regression models, showing the suitability of the portable Micro-NIR for in field monitoring of chemical parameters of interest in acerola fruits. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Recent, climate-driven river incision rate fluctuations in the Mercantour crystalline massif, southern French Alps

    Science.gov (United States)

    Petit, C.; Goren, L.; Rolland, Y.; Bourlès, D.; Braucher, R.; Saillard, M.; Cassol, D.

    2017-06-01

    We present a new geomorphological analysis of the Tinée River tributaries in the southern French Alps based on numerical inverse and forward modelling of their longitudinal profiles. We model their relative uplift history with respect to the main channel, hence the incision rate history of this channel. Inverse models show that all tributaries have consistent incision rate histories with alternating high and low values. A comparison with global temperature curves shows that these variations correlate with quaternary climate changes. We suggest that during warm periods, a wave of regressive erosion propagates in the Tinée River, while its tributaries deeply incise their substratum to catch up with the falling base-level. We also show that the post 140 ka history of this landscape evolution is dominated by fluvial incision. We then perform forward models of river incision and simulate the incision of the Tinée River system over a time span of 600 ka. This model allows us to extract time and space incision rate variations of the Tinée River. With a background of a few mm.yr-1, incision rate can increase up to more than 1 cm yr-1 during short periods of time due to climatic oscillations. This result is compatible with published cosmogenic nuclide based dating, which evidenced incision rates from 0.2 to 24 mm yr-1. The part of the channel located between 12 and 20 km downstream from the source has undergone several periods of rapid incision rates, which could explain the steep hillslopes and the triggering of a landslide ∼10 ka ago.

  3. Micrococcus luteus correndonucleases. III. Evidence for involvement in repair in vivo of two endonucleases specific for DNA containing pyrimidine dimers

    International Nuclear Information System (INIS)

    Riazuddin, S.; Grossman, L.; Mahler, I.

    1977-01-01

    Involvement of Py--Py correndonucleases I and II in repair of ultraviolet radiation damage in vivo by Micrococcus luteus has been demonstrated by their absence in the ultraviolet-sensitive mutant DB-7 derived by treatment of the wild type parent with N-methyl-N'-nitro-N-nitrosoguanidine. The necessity for their combined action in DNA repair in M. luteus is shown by: (a) reactivation of ultraviolet-damaged phiX174 RFI DNA in incision-defective hosts after in vivo treatment with both enzymes, (b) correlation between survival after ultraviolet irradiation and the level of the two enzymes, and (c) increased levels of repair synthesis after ultraviolet irradiation of toluenized cells DB-400 with wild type correndonuclease levels when compared with the transformant DB-200 and the mutant DB-7, which lack one or both enzymes

  4. [External periareolar incision for subdermal mastectomy in men with gynecomastia].

    Science.gov (United States)

    Montiel-Jarquín, Alvaro; Reyes-Páramo, Pedro; Ramos-Alvarez, Gloria; López-Colombo, Aurelio; Tinajero-Esquivel, Magdalena; Ruiz-León, Betzabé

    2007-01-01

    Gynecomastia describes a benign increase of the mammary gland in men. When medical treatment fails, symptoms and psychological alterations persist. Subdermal mastectomy is the definitive treatment and can be achieved by different incisions, each with potential complications. We undertook this study to present clinical characteristics of 11 patients with gynecomastia and the results obtained with subdermal mastectomy by means of external periareolar incision. A descriptive cohort study in male patients with gynecomastia was carried out in a third-level medical care hospital. Patients were treated with subdermal mastectomy by means of external periareolar incision. There were 11 male patients with an average age of 19 years (range: 11-60 years), 3 patients (27.2%) with bilateral gynecomastia and 8 patients (72.7%) with unilateral gynecomastia. Average time of evolution was 22 months (range: 16-48 months), 9 patients (81.8%) reported pain, 11 patients (100%) reported psychological alterations with cutaneous alteration, 11 patients (100%) had normal secondary sexual characteristics, 1 patient (9%) had supernumerary nipple development, and 11 patients (100%) had well-defined lesions. According to Simon's classification: seven patients (63.6%) were classified as grade 1, three patients (27.2%) as grade 2 and one patient (9.09%) as grade 3. Each patient had a subdermal mastectomy with external periareolar incision, 11 patients (100%) had a histopathological report of gynecomastia; 1 patient (9.09%) displayed keloid healing and none displayed complications inherent to the surgical procedure. Mastectomy by means of external periareolar incision is useful in the treatment of gynecomastia.

  5. Incision of the Jezero Crater Outflow Channel by Fluvial Sediment Transport

    Science.gov (United States)

    Holo, S.; Kite, E. S.

    2017-12-01

    Jezero crater, the top candidate landing site for the Mars 2020 rover, once possessed a lake that over-spilled and eroded a large outflow channel into the Eastern rim. The Western deltaic sediments that would be the primary science target of the rover record a history of lake level, which is modulated by the inflow and outflow channels. While formative discharges for the Western delta exist ( 500 m3/s), little work has been done to see if these flows are the same responsible for outflow channel incision. Other models of the Jezero outflow channel incision assume that a single rapid flood (incision timescales of weeks), with unknown initial hydraulic head and no discharge into the lake (e.g. from the inflow channels or the subsurface), incised an open channel with discharge modulated by flow over a weir. We present an alternate model where, due to an instability at the threshold of sediment motion, the incision of the outflow channel occurs in concert with lake filling. In particular, we assume a simplified lake-channel-valley system geometry and that the channel is hydraulically connected to the filling/draining crater lake. Bed load sediment transport and water discharge through the channel are quantified using the Meyer-Peter and Mueller relation and Manning's law respectively. Mass is conserved for both water and sediment as the lake level rises/falls and the channel incises. This model does not resolve backwater effects or concavity in the alluvial system, but it does capture the non-linear feedbacks between lake draining, erosion rate, channel flow rate, and slope relaxation. We identify controls on incision of the outflow channel and estimate the time scale of outflow channel formation through a simple dynamical model. We find that the observed 300m of channel erosion can be reproduced in decades to centuries of progressive bed load as the delta forming flows fill the lake. This corresponds to time scales on the order of or smaller than the time scale

  6. ON THE DISTANCE OF THE MAGELLANIC CLOUDS USING CEPHEID NIR AND OPTICAL-NIR PERIOD-WESENHEIT RELATIONS

    International Nuclear Information System (INIS)

    Inno, L.; Bono, G.; Buonanno, R.; Genovali, K.; Matsunaga, N.; Caputo, F.; Laney, C. D.; Marconi, M.; Piersimoni, A. M.; Primas, F.; Romaniello, M.

    2013-01-01

    We present the largest near-infrared (NIR) data sets, JHKs, ever collected for classical Cepheids in the Magellanic Clouds (MCs). We selected fundamental (FU) and first overtone (FO) pulsators, and found 4150 (2571 FU, 1579 FO) Cepheids for Small Magellanic Cloud (SMC) and 3042 (1840 FU, 1202 FO) for Large Magellanic Cloud (LMC). Current sample is 2-3 times larger than any sample used in previous investigations with NIR photometry. We also discuss optical VI photometry from OGLE-III. NIR and optical-NIR Period-Wesenheit (PW) relations are linear over the entire period range (0.0 FU ≤ 1.65) and their slopes are, within the intrinsic dispersions, common between the MCs. These are consistent with recent results from pulsation models and observations suggesting that the PW relations are minimally affected by the metal content. The new FU and FO PW relations were calibrated using a sample of Galactic Cepheids with distances based on trigonometric parallaxes and Cepheid pulsation models. By using FU Cepheids we found a true distance moduli of 18.45 ± 0.02(random) ± 0.10(systematic) mag (LMC) and 18.93 ± 0.02(random) ± 0.10(systematic) mag (SMC). These estimates are the weighted mean over 10 PW relations and the systematic errors account for uncertainties in the zero point and in the reddening law. We found similar distances using FO Cepheids (18.60 ± 0.03(random) ± 0.10(systematic) mag (LMC) and 19.12 ± 0.03(random) ± 0.10(systematic) mag (SMC)). These new MC distances lead to the relative distance, Δμ = 0.48 ± 0.03 mag (FU, log P = 1) and Δμ = 0.52 ± 0.03 mag (FO, log P = 0.5), which agrees quite well with previous estimates based on robust distance indicators.

  7. Force modeling for incisions into various tissues with MRF haptic master

    Science.gov (United States)

    Kim, Pyunghwa; Kim, Soomin; Park, Young-Dai; Choi, Seung-Bok

    2016-03-01

    This study proposes a new model to predict the reaction force that occurs in incisions during robot-assisted minimally invasive surgery. The reaction force is fed back to the manipulator by a magneto-rheological fluid (MRF) haptic master, which is featured by a bi-directional clutch actuator. The reaction force feedback provides similar sensations to laparotomy that cannot be provided by a conventional master for surgery. This advantage shortens the training period for robot-assisted minimally invasive surgery and can improve the accuracy of operations. The reaction force modeling of incisions can be utilized in a surgical simulator that provides a virtual reaction force. In this work, in order to model the reaction force during incisions, the energy aspect of the incision process is adopted and analyzed. Each mode of the incision process is classified by the tendency of the energy change, and modeled for realistic real-time application. The reaction force model uses actual reaction force information with three types of actual tissues: hard tissue, medium tissue, and soft tissue. This modeled force is realized by the MRF haptic master through an algorithm based on the position and velocity of a scalpel using two different control methods: an open-loop algorithm and a closed-loop algorithm. The reaction forces obtained from the proposed model are compared with a desired force in time domain.

  8. Force modeling for incisions into various tissues with MRF haptic master

    International Nuclear Information System (INIS)

    Kim, Pyunghwa; Kim, Soomin; Park, Young-Dai; Choi, Seung-Bok

    2016-01-01

    This study proposes a new model to predict the reaction force that occurs in incisions during robot-assisted minimally invasive surgery. The reaction force is fed back to the manipulator by a magneto-rheological fluid (MRF) haptic master, which is featured by a bi-directional clutch actuator. The reaction force feedback provides similar sensations to laparotomy that cannot be provided by a conventional master for surgery. This advantage shortens the training period for robot-assisted minimally invasive surgery and can improve the accuracy of operations. The reaction force modeling of incisions can be utilized in a surgical simulator that provides a virtual reaction force. In this work, in order to model the reaction force during incisions, the energy aspect of the incision process is adopted and analyzed. Each mode of the incision process is classified by the tendency of the energy change, and modeled for realistic real-time application. The reaction force model uses actual reaction force information with three types of actual tissues: hard tissue, medium tissue, and soft tissue. This modeled force is realized by the MRF haptic master through an algorithm based on the position and velocity of a scalpel using two different control methods: an open-loop algorithm and a closed-loop algorithm. The reaction forces obtained from the proposed model are compared with a desired force in time domain. (paper)

  9. Single incision laparoscopic pancreas resection for pancreatic metastasis of renal cell carcinoma.

    Science.gov (United States)

    Barbaros, Umut; Sümer, Aziz; Demirel, Tugrul; Karakullukçu, Nazlı; Batman, Burçin; Içscan, Yalın; Sarıçam, Gülay; Serin, Kürçsat; Loh, Wei-Liang; Dinççağ, Ahmet; Mercan, Selçuk

    2010-01-01

    Transumbilical single incision laparoscopic surgery (SILS) offers excellent cosmetic results and may be associated with decreased postoperative pain, reduced need for analgesia, and thus accelerated recovery. Herein, we report the first transumbilical single incision laparoscopic pancreatectomy case in a patient who had renal cell cancer metastasis on her pancreatic corpus and tail. A 59-year-old female who had metastatic lesions on her pancreas underwent laparoscopic subtotal pancreatectomy through a 2-cm umbilical incision. Single incision pancreatectomy was performed with a special port (SILS port) and articulated equipment. The procedure lasted 330 minutes. Estimated blood loss was 100mL. No perioperative complications occurred. The patient was discharged on the seventh postoperative day with a low-volume (20mL/day) pancreatic fistula that ceased spontaneously. Pathology result of the specimen was renal cell cancer metastases. This is the first reported SILS pancreatectomy case, demonstrating that even advanced surgical procedures can be performed using the SILS technique in well-experienced centers. Transumbilical single incision laparoscopic pancreatectomy is feasible and can be performed safely in experienced centers. SILS may improve cosmetic results and allow accelerated recovery for patients even with malignancy requiring advanced laparoscopic interventions.

  10. Mislocalization of XPF-ERCC1 nuclease contributes to reduced DNA repair in XP-F patients.

    Directory of Open Access Journals (Sweden)

    Anwaar Ahmad

    2010-03-01

    Full Text Available Xeroderma pigmentosum (XP is caused by defects in the nucleotide excision repair (NER pathway. NER removes helix-distorting DNA lesions, such as UV-induced photodimers, from the genome. Patients suffering from XP exhibit exquisite sun sensitivity, high incidence of skin cancer, and in some cases neurodegeneration. The severity of XP varies tremendously depending upon which NER gene is mutated and how severely the mutation affects DNA repair capacity. XPF-ERCC1 is a structure-specific endonuclease essential for incising the damaged strand of DNA in NER. Missense mutations in XPF can result not only in XP, but also XPF-ERCC1 (XFE progeroid syndrome, a disease of accelerated aging. In an attempt to determine how mutations in XPF can lead to such diverse symptoms, the effects of a progeria-causing mutation (XPF(R153P were compared to an XP-causing mutation (XPF(R799W in vitro and in vivo. Recombinant XPF harboring either mutation was purified in a complex with ERCC1 and tested for its ability to incise a stem-loop structure in vitro. Both mutant complexes nicked the substrate indicating that neither mutation obviates catalytic activity of the nuclease. Surprisingly, differential immunostaining and fractionation of cells from an XFE progeroid patient revealed that XPF-ERCC1 is abundant in the cytoplasm. This was confirmed by fluorescent detection of XPF(R153P-YFP expressed in Xpf mutant cells. In addition, microinjection of XPF(R153P-ERCC1 into the nucleus of XPF-deficient human cells restored nucleotide excision repair of UV-induced DNA damage. Intriguingly, in all XPF mutant cell lines examined, XPF-ERCC1 was detected in the cytoplasm of a fraction of cells. This demonstrates that at least part of the DNA repair defect and symptoms associated with mutations in XPF are due to mislocalization of XPF-ERCC1 into the cytoplasm of cells, likely due to protein misfolding. Analysis of these patient cells therefore reveals a novel mechanism to potentially

  11. A preliminary investigation into the extent of increased radioresistance or hyper-radiosensitivity in cells of hamster cell lines known to be deficient in DNA repair

    International Nuclear Information System (INIS)

    Skov, K.; Marples, B.; Matthews, J.B.; Zhou, H.; Joiner, M.C.

    1994-01-01

    The response to low doses of X rays was assessed in cells of three hamster cell lines which are defective in DNA repair and was compared with their parental lines. Cells of the V79-derived double-strand break repair-deficient line XR-V15B showed no radioresistance in the 0.5-Gy range compared with the V79B wild type, but instead showed an exponential response. Cells of the single-strand break repair-deficient line EM9 showed hyper-radiosensitivity and exhibited increased radioresistance. Most interestingly, cells of the UV-20 cell line appeared to respond exponentially, as a continuation of the hyper-radiosensitive portion of the curve, with no evidence of increased radioresistance. This line is defective in an incision step of excision repair and is sensitive to crosslinking agents. Further studies are warranted to address the possible role of single- and double-strand break repair and excision repair in hyper-radiosensitivity and increased radioresistance. 24 refs., 4 figs

  12. NIR: optimerer produktionen af gammeldags modnede sild

    DEFF Research Database (Denmark)

    Svensson, T.; Bro, Rasmus; Nielsen, Henrik Hauch

    2005-01-01

    Måling med nærinfrarødt (NIR) lys er et godt supplement til de nuværende metoder til at følge modningen af sild saltede i tønder. Det viser resultaterne af et forskningsprojekt udført i samarbejde mellem Lykkeberg A/S, Danmarks Fiskeriundersøgelser og Den Kgl Veterinær- og Landbohøjskole. Ved hjælp...... af avanceret matematik er det nemt og hurtigt at bestemme modningsgraden af sild direkte fra en NIR måling....

  13. Related issues in repair of bile duct injury and traumatic biliary stricture

    Directory of Open Access Journals (Sweden)

    WANG Shuguang

    2017-02-01

    Full Text Available Inappropriate treatment of bile duct injury and traumatic biliary stricture may cause serious consequences such as recurrent cholangitis, formation of hepatolithiasis, and biliary cirrhosis. This article elaborates on the influencing factors for the effect of the repair of bile duct injury and traumatic biliary stricture, repair principles, timing of repair or reconstruction, and related methods and techniques. It is pointed out that if there is no significant local infection and the bile duct wall defect is <2 cm, end-to-end anastomosis should be used for repair; if the bile duct wall defect is >2 cm, Roux-en-Y hepaticojejunostomy should be used for reconstruction. If the upper wall of the bile duct had a large defect and the lower wall has an integral structure, pedicled umbilical vein graft, pedicled jejunal wall seromuscular flap, or gastric wall seromuscular flap should be used for repair. The patients with severe congestion and edema at the site of injury should be treated with sufficient external drainage of the injured bile duct and then selective repair or reconstruction. Patients with hepatic duct stenosis in the liver lobe or hepatic segments and liver tissue atrophy can be treated with hepalobectomy or segmental hepatectomy. The key to successful repair is exposure and removal of high hilar bile duct stricture, while segmental hepatectomy of the Ⅳb segment can fully expose the left and right hepatic pedicles and help with the incision of the left and right hepatic ducts and secondary hepatic ducts, and therefore, it is a good method for exposing high bile duct stricture.

  14. 1-{beta}-D-arabinofuranosylcytosine is cytotoxic in quiescent normal lymphocytes undergoing DNA excision repair

    Energy Technology Data Exchange (ETDEWEB)

    Yamauchi, Takahiro; Kawai, Yasukazu; Ueda, Takanori [Fukui Medical Univ., Matsuoka (Japan)

    2002-12-01

    We have sought to clarify the potential activity of the S-phase-specific antileukemic agent 1-{beta}-D-arabinofuranosylcytosine (ara-C), an inhibitor of DNA synthesis, in quiescent cells that are substantially non-sensitive to nucleoside analogues. It was hypothesized that the combination of ara-C with DNA damaging agents that initiate DNA repair will expand ara-C cytotoxicity to non-cycling cells. The repair kinetics, which included incision of damaged DNA, gap-filling by DNA synthesis and rejoining by ligation, were evaluated using the single cell gel electrophoresis (Comet) assay and the thymidine incorporation assay. When normal lymphocytes were treated with ultraviolet C or with 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU), the processes of DNA excision repair were promptly initiated and rapidly completed. When the cells were incubated with ara-C prior to irradiation or BCNU treatment, the steps of DNA synthesis and rejoining in the repair processes were both inhibited. The ara-C-mediated inhibition of the repair processes was concentration-dependent, with the effect peaking at 10{mu}M. The combination of ara-C with these DNA repair initiators exerted subsequent cytotoxicity, which was proportional to the extent of the repair inhibition in the presence of ara-C. In conclusion, ara-C was cytotoxic in quiescent cells undergoing DNA repair. This might be attributed to unrepaired DNA damage that remained in the cells, thereby inducing lethal cytotoxicity. Alternatively, ara-C might exert its own cytotoxicity by inhibiting DNA synthesis in the repair processes. Such a strategy may be effective against a dormant subpopulation in acute leukemia that survives chemotherapy. (author)

  15. 1-β-D-arabinofuranosylcytosine is cytotoxic in quiescent normal lymphocytes undergoing DNA excision repair

    International Nuclear Information System (INIS)

    Yamauchi, Takahiro; Kawai, Yasukazu; Ueda, Takanori

    2002-01-01

    We have sought to clarify the potential activity of the S-phase-specific antileukemic agent 1-β-D-arabinofuranosylcytosine (ara-C), an inhibitor of DNA synthesis, in quiescent cells that are substantially non-sensitive to nucleoside analogues. It was hypothesized that the combination of ara-C with DNA damaging agents that initiate DNA repair will expand ara-C cytotoxicity to non-cycling cells. The repair kinetics, which included incision of damaged DNA, gap-filling by DNA synthesis and rejoining by ligation, were evaluated using the single cell gel electrophoresis (Comet) assay and the thymidine incorporation assay. When normal lymphocytes were treated with ultraviolet C or with 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU), the processes of DNA excision repair were promptly initiated and rapidly completed. When the cells were incubated with ara-C prior to irradiation or BCNU treatment, the steps of DNA synthesis and rejoining in the repair processes were both inhibited. The ara-C-mediated inhibition of the repair processes was concentration-dependent, with the effect peaking at 10μM. The combination of ara-C with these DNA repair initiators exerted subsequent cytotoxicity, which was proportional to the extent of the repair inhibition in the presence of ara-C. In conclusion, ara-C was cytotoxic in quiescent cells undergoing DNA repair. This might be attributed to unrepaired DNA damage that remained in the cells, thereby inducing lethal cytotoxicity. Alternatively, ara-C might exert its own cytotoxicity by inhibiting DNA synthesis in the repair processes. Such a strategy may be effective against a dormant subpopulation in acute leukemia that survives chemotherapy. (author)

  16. Manual small incision extracapsular cataract surgery in Australia.

    Science.gov (United States)

    van Zyl, Lourens; Kahawita, Shyalle; Goggin, Michael

    2014-11-01

    Examination of the results and describing the technique of manual small incision extracapsular cataract extraction on patients with advanced cataracts in urban Australia. A descriptive case series. Thirty-eight patients at three public hospitals, one tertiary and two secondary ophthalmic units in urban Australia. Forty eyes with dense mature cataracts with hand movement vision or worse underwent a planned manual small incision extracapsular cataract extraction instead of traditional phaco-emulsification. Postoperative visual aquity, surgically induced astigmatism and complications. Seventy-eight per cent of patients had an uncorrected visual acuity of 6/12 or better on the first postoperative day. Eighty-three per cent of patients had a distance corrected visual acuity of 6/9 or better 3 months postoperatively. One case was complicated by a posterior capsule rupture. No cases of endophthalmitis were reported. The summated vector mean of the surgically induced astigmatism was 0.089D at 93°. Manual small incision extracapsular cataract extraction is an efficacious cataract surgery technique with good visual outcome and is a safe alternative to phaco-emulsification in suitable cases in a first-world setting. © 2014 Royal Australian and New Zealand College of Ophthalmologists.

  17. Surgically induced astigmatism after 3.0 mm temporal and nasal clear corneal incisions in bilateral cataract surgery

    Directory of Open Access Journals (Sweden)

    Je Hwan Yoon

    2013-01-01

    Full Text Available Aims: To compare the corneal refractive changes induced after 3.0 mm temporal and nasal corneal incisions in bilateral cataract surgery. Materials and Methods: This prospective study comprised a consecutive case series of 60 eyes from 30 patients with bilateral phacoemulsification that were implanted with a 6.0 mm foldable intraocular lens through a 3.0 mm horizontal clear corneal incision (temporal in the right eyes, nasal in the left eyes. The outcome measures were surgically induced astigmatism (SIA and uncorrected visual acuity (UCVA 1 and 3 months, post-operatively. Results: At 1 month, the mean SIA was 0.81 diopter (D for the temporal incisions and 0.92 D for nasal incisions (P = 0.139. At 3 months, the mean SIA were 0.53 D for temporal incisions and 0.62 D for nasal incisions (P = 0.309. The UCVA was similar in the 2 incision groups before surgery, and at 1 and 3 months post-operatively. Conclusion: After bilateral cataract surgery using 3.0 mm temporal and nasal horizontal corneal incisions, the induced corneal astigmatic change was similar in both incision groups. Especially in Asian eyes, both temporal and nasal incisions (3.0 mm or less would be favorable for astigmatism-neutral cataract surgery.

  18. Aorta-atria-septum combined incision for aortic valve re-replacement

    Science.gov (United States)

    Xu, Yiwei; Ye, Xiaofeng; Li, Zhaolong

    2018-01-01

    This case report illustrates a patient who underwent supra-annular mechanical aortic valve replacement then suffered from prosthesis dysfunction, increasing pressure gradient with aortic valve. She was successfully underwent aortic valve re-replacement, sub-annular pannus removing and aortic annulus enlargement procedures through combined cardiac incision passing through aortic root, right atrium (RA), and upper atrial septum. This incision provides optimal visual operative field and simplifies dissection. PMID:29850170

  19. Postoperative analgesic efficiency of transversus abdominis plane block after ventral hernia repair: a prospective, randomized, controlled clinical trial.

    Science.gov (United States)

    Chesov, Ion; Belîi, Adrian

    2017-10-01

    Effective postoperative analgesia is a key element in reducing postoperative morbidity, accelerating recovery and avoiding chronic postoperative pain. The aim of this study was to evaluate the effectiveness of ultrasound-guided Transversus Abdominis Plane (TAP) block, performed before surgical incision, in providing postoperative analgesia for patients undergoing open ventral hernia repair under general anaesthesia. Seventy elective patients scheduled for open ventral hernia repair surgery under general anaesthesia were divided randomly into two equal groups: Group I received bilateral TAP block performed before surgical incision (n = 35); Group II received systemic postoperative analgesia with parenteral opioid (morphine) alone (n = 35). Postoperatively pain scores at rest and with movement, total morphine consumption and opioid related side effects were recorded. Postoperative pain scores at rest and mobilization/cough were significantly higher in patients without TAP block (p consumption was comparable between the two groups: 0.75 ± 0.31 mg in group I (TAP) and 0.86 ± 0.29 mg in group II (MO), p = 0.1299. Patients undergoing preincisional TAP block had reduced morphine requirements during the first 24 hours after surgery, compared to patients from group II, without TAP block (p = 0.0001). There was no difference in the incidence of opioid related side effects (nausea, vomiting) in the both groups during the first 24 postoperative hours. The use of preincisional ultrasound guided TAP block reduced the pain scores at rest and with movement/cough, opioid consumption and opioid-related side effects after ventral hernia repair when compared with opioid-only analgesia.

  20. Biological significance of facilitated diffusion in protein-DNA interactions. Applications to T4 endonuclease V-initiated DNA repair

    International Nuclear Information System (INIS)

    Dowd, D.R.; Lloyd, R.S.

    1990-01-01

    Facilitated diffusion along nontarget DNA is employed by numerous DNA-interactive proteins to locate specific targets. Until now, the biological significance of DNA scanning has remained elusive. T4 endonuclease V is a DNA repair enzyme which scans nontarget DNA and processively incises DNA at the site of pyrimidine dimers which are produced by exposure to ultraviolet (UV) light. In this study we tested the hypothesis that there exists a direct correlation between the degree of processivity of wild type and mutant endonuclease V molecules and the degree of enhanced UV resistance which is conferred to repair-deficient Eshcerichia coli. This was accomplished by first creating a series of endonuclease V mutants whose in vitro catalytic activities were shown to be very similar to that of the wild type enzyme. However, when the mechanisms by which these enzymes search nontarget DNA for its substrate were analyzed in vitro and in vivo, the mutants displayed varying degrees of nontarget DNA scanning ranging from being nearly as processive as wild type to randomly incising dimers within the DNA population. The ability of these altered endonuclease V molecules to enhance UV survival in DNA repair-deficient E. coli then was assessed. The degree of enhanced UV survival was directly correlated with the level of facilitated diffusion. This is the first conclusive evidence directly relating a reduction of in vivo facilitated diffusion with a change in an observed phenotype. These results support the assertion that the mechanisms which DNA-interactive proteins employ in locating their target sites are of biological significance

  1. Novel self-assembled sandwich nanomedicine for NIR-responsive release of NO

    Science.gov (United States)

    Fan, Jing; He, Qianjun; Liu, Yi; Ma, Ying; Fu, Xiao; Liu, Yijing; Huang, Peng; He, Nongyue; Chen, Xiaoyuan

    2015-01-01

    A novel sandwich nanomedicine (GO-BNN6) for near-infrared (NIR) light responsive release of nitric oxide (NO) has been constructed by self-assembling of graphene oxide (GO) nanosheets and a NO donor BNN6 through the π-π stacking interaction. GO-BNN6 nanomedicine has an extraordinarily high drug loading capacity (1.2 mg BNN6 per mg GO), good thermal stability, and high NIR responsiveness. The NO release from GO-BNN6 can be easily triggered and effectively controlled by adjusting the switching, irradiation time and power density of NIR laser. The intracellular NIR-responsive release of NO from GO-BNN6 nanomedicine causes a remarkable anti-cancer effect. PMID:26568270

  2. Minimal incision surgery in strabismus: Modified fornix-based approach.

    Science.gov (United States)

    Pérez-Flores, I

    2016-07-01

    To evaluate the modified fornix-based technique as an approach for minimal incision surgery in strabismus. The medical records of all consecutive patients that underwent strabismus surgery with fornix-based conjunctival incision between 2007 and 2012 were retrospectively reviewed. As a primary variable, an analysis was made of the wound size depending on the number of stitches. A descriptive study was performed on the variables related to patients and to the type of strabismus and surgery. Out of 153patients identified, 138 with 294 surgeries were included. In 200 (68%) interventions, the incision was sutured with one stitch, in 77 (26.2%) with 2, in 13 (4.4%) with 3, and in 4 (1.4%) with 4, with the mean number of stitches being 1.39±0.64. The mean age of the patients was 39years (2-80), and 36 (26.1%) had previous strabismus surgery, with topical anaesthesia being used in 35 (25.4%) cases. At 3months after surgery deviation was ≤10DP in 114 (82.6%) patients. There were no wound-related complications. The modified fornix-based technique is an effective and safe approach for minimal incision surgery in strabismus, in patients at all ages, with previous history of strabismus surgery and with topical anaesthesia. Copyright © 2015 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  3. Outcomes of single-stage total arch replacement via clamshell incision

    Directory of Open Access Journals (Sweden)

    Ishizaka Toru

    2011-09-01

    Full Text Available Abstract Background Treatment of complex aortic pathologies involving the transverse arch with extensive involvement of the descending aorta remains a surgical challenge. Since clamshell incision provides superior exposure of the entire thoracic aorta, we evaluated the use of this technique for single-stage total arch replacement by arch vessel reconstruction. Methods The arch-first technique combined with clamshell incision was used in 38 cases of aneurysm and aortic disease in 2008 and 2009. Extensive total arch replacement was used with clamshell incision for reconstruction of arch vessels under deep hypothermic circulatory arrest. Results Overall 30-day mortality was 13%. The mean operating time was approximately 8 hours. Deep hypothermia resulted in mean CPB time exceeding 4.5 hours and mean duration of circulatory arrest was 25 minutes. The overall postoperative temporary and permanent neurologic dysfunction rates were 3% and 3% for elective and 3% and 0% for emergency surgery, respectively. All patients except the five who died in hospital were discharged without nursing care after an average post-operative hospital stay of 35 days. Conclusions The arch-first technique, combined with clamshell incision, provides expeditious replacement of the thoracic aorta with an acceptable duration of hypothermic circulatory arrest and minimizes the risk of retrograde atheroembolism by using antegrade perfusion.

  4. Present status of the NIRS-ECR ion source for the HIMAC

    International Nuclear Information System (INIS)

    Kitagawa, A.; Matsushita, H.; Shibuya, S.

    1995-01-01

    The present status of NIRS-ECR ion source for the Heavy Ion Medical Accelerator in Chiba (HIMAC) at National Institute of Radiological Sciences (NIRS) is reported. The beam intensity of the NIRS-ECR was increased by modifications on the magnetic field structure, chamber cooling system, vacuum conductance and the extraction configuration. The output current of Ar 6+ reached 365 eμA after improvements. The good stability, easy operation, and good reproducibility were realized. (author)

  5. Evaluation of a new disposable silicon limbal relaxing incision knife by experienced users.

    Science.gov (United States)

    Albanese, John; Dugue, Geoffrey; Parvu, Valentin; Bajart, Ann M; Lee, Edwin

    2009-12-21

    Previous research has suggested that the silicon BD Atomic Edge knife has superior performance characteristics when compared to a metal knife and performance similar to diamond knife when making various incisions. This study was designed to determine whether a silicon accurate depth knife has equivalent performance characteristics when compared to a diamond limbal relaxing incision (LRI) knife and superior performance characteristics when compared to a steel accurate depth knife when creating limbal relaxing incision. Sixty-five ophthalmic surgeons with limbal relaxing incision experience created limbal relaxing incisions in ex-vivo porcine eyes with silicon and steel accurate depth knives and diamond LRI knives. The ophthalmic surgeons rated multiple performance characteristics of the knives on Visual Analog Scales. The observed differences between the silicon knife and diamond knife were found to be insignificant. The mean ratio between the performance of the silicon knife and the diamond knife was shown to be greater than 90% (with 95% confidence). The silicon knife's mean performance was significantly higher than the performance of the steel knife for all characteristics. (p-value knife was found to be equivalent in performance to the diamond LRI knife and superior to the steel accurate depth knife when making limbal relaxing incisions in ex vivo porcine eyes. Disposable silicon LRI knives may be an alternative to diamond LRI knives.

  6. Wound repair in rat urinary bladder following electrocautery or holmium laser incision

    Science.gov (United States)

    Venzi, Giordano; Schmidlin, Franz R.; Gabbiani, Giulio; Delacretaz, Guy P.; Pittet, Brigitte; Leisinger, Hans-Juerg; Iselin, Christoph E.

    1999-06-01

    Woundhealing is a complex phenomenon which varies according the type of tissue but is also depending from the type of tissue injury. Electrocautery mainly induces coagulation necrosis while thermal damages induced by the Holmium laser primarily lead to tissue vaporization which may induce less tissue injury. The aim of this study was to evaluate the healing process of the Holmium laser induced lesions compared to electrocautery induced lesions in urothelial tissue by assessing the inflammatory response and myofibroblast behavior in sequential healing phases. A surgical wound was created in the urinary rat bladder of 32 rats either by electrocautery or by laser (N=16). The inflammatory response, the total lesion depth and the myofibroblast activity during woundhealing was then analyzed on a qualitative basis on days 0/2/4/8. The overall inflammatory response was comparable in both groups up to days two and four. However, at day eight less cellular inflammatory reaction and less myofibroblast activity was found in the specimen of lesions created by the Holmium laser. These results suggest that wound repair may be a less invasive process after Holmium laser than electrocautery.

  7. Delayed Cerebral Ischemia following to Repair of Penetrating Trauma to External Carotid artery Introduction

    Directory of Open Access Journals (Sweden)

    M. Eskandarlou

    2016-01-01

    Full Text Available Introduction: Penetrating trauma to anterior neck can induce cerebral ischemia due to carotid artery injury. Brain ischemia also can present after surgical carotid repairs. Early diagnosis and suitable treatment modality prevent from permanent neurologic deficit post operatively. Case Report: A 30 years old man with stab wound to zone two left side of neck underwent exploration and penrose insertion. Due to excessive bleeding through drain tube, patient was transferred to Besat Hospital of Hamadan. Surgical repair of external carotid artery successfully was done. Four days later patient developed right hemiparesis suddenly. According to MRI and color Doppler sonography finding of thrombosis of left common and internal carotid artery, reoperation was done. After thrombectomy cerebral ischemia and hemi-paralysis improved. Conclusions: Surgical approach to symptomatic penetrating neck trauma is oblique cervical incision, control of bleeding, repair of internal carotid, repair or ligature of external carotid artery base on some factors and preferential repair of internal jugular vein. Meticulous and fine surgical technique for both vascular repair and protection of adjacent normal vessels for avoiding to blunt trauma or compression with retractors is noticeable. Exact postoperative care as repeated clinical examination with goal of early diagnosis of internal carotid artery thrombosis and rapid diagnostic and treatment planning of this complication are important factors for taking of good result in treatment of penetrating trauma to carotid. Sci J Hamadan Univ Med Sci . 2016; 22 (4 :353-357

  8. Climate-sensitive feedbacks between hillslope processes and fluvial erosion in sediment-driven incision models

    Science.gov (United States)

    Skov, Daniel S.; Egholm, David L.

    2016-04-01

    Surface erosion and sediment production seem to have accelerated globally as climate cooled in the Late Cenozoic, [Molnar, P. 2004, Herman et al 2013]. Glaciers emerged in many high mountain ranges during the Quaternary, and glaciation therefore represents a likely explanation for faster erosion in such places. Still, observations and measurements point to increases in erosion rates also in landscapes where erosion is driven mainly by fluvial processes [Lease and Ehlers (2013), Reusser (2004)]. Flume experiments and fieldwork have shown that rates of incision are to a large degree controlled by the sediment load of streams [e.g. Sklar and Dietrich (2001), Beer and Turowski (2015)]. This realization led to the formulation of sediment-flux dependent incision models [Sklar and Dietrich (2004)]. The sediment-flux dependence links incision in the channels to hillslope processes that supply sediment to the channels. The rates of weathering and soil transport on the hillslopes are processes that are likely to respond to changing temperatures, e.g. because of vegetation changes or the occurrence of frost. In this study, we perform computational landscape evolution experiments, where the coupling between fluvial incision and hillslope processes is accounted for by coupling a sediment-flux-dependent model for fluvial incision to a climate-dependent model for weathering and hillslope sediment transport. The computational experiments first of all demonstrate a strong positive feedback between channel and hillslope processes. In general, faster weathering leads to higher rates of channel incision, which further increases the weathering rates, mainly because of hillslope steepening. Slower weathering leads to the opposite result. The experiments also demonstrate, however, that the feedbacks vary significantly between different parts of a drainage network. For example, increasing hillslope sediment production may accelerate incision in the upper parts of the catchment, while at

  9. Comparison of the effects of 23-gauge and 25-gauge microincision vitrectomy blade designs on incision architecture

    Directory of Open Access Journals (Sweden)

    Inoue M

    2014-11-01

    Full Text Available Makoto Inoue,1 Dina Joy K Abulon,2 Akito Hirakata1 1Kyorin Eye Center, School of Medicine, Kyorin University, Tokyo, Japan; 2Alcon Research, Ltd., Irvine, CA, USA Purpose: To compare the effects of different 23- and 25-gauge microincision vitrectomy trocar cannula entry systems on incision architecture.Methods: We tested one ridged microvitreoretinal (MVR, one non-ridged MVR, one pointed beveled, and one round-tipped beveled blade (n=10 per blade design per incision type. Each blade’s straight and oblique incision architecture was assessed in a silicone disc simulating the sclera. Wound leakage under pressure and endoscopic observations were conducted on sclerotomy sites of isolated porcine eyes (n=4 per blade design after simulated vitrectomy.Results: Differences in blade design created distinct incision architecture. Incisions were linear with the ridged MVR blade, flattened “M-shaped” with the non-ridged MVR blade, asymmetrical chevron-shaped with the pointed beveled blade, and curved with the round-tipped beveled blade. With the exception of oblique entry incision thickness, both MVR blade designs created thinner incisions than the beveled blades at entry and exit sites. Only the ridged MVR blade created incisions with no leakage. Vitreous incarceration was observed with all trocar cannula systems.Conclusion: Wound closure in porcine eyes was similar with all blades despite differences in incision architecture. Wound leakage occurred at low to moderate infusion pressures with most blades; no wound leakage was observed with ridged MVR blades. Keywords: entry system, incision closure, leakage, pars plana incision, sclerotomy, trocar blade 

  10. The contemporary role of 1 vs. 2-stage repair for proximal hypospadias.

    Science.gov (United States)

    Dason, Shawn; Wong, Nathan; Braga, Luis H

    2014-12-01

    This review discusses the most commonly employed techniques in the repair of proximal hypospadias, highlighting the advantages and disadvantages of single versus staged surgical techniques. Hypospadias can have a spectrum of severity with a urethral meatus ranging from the perineum to the glans. Associated abnormalities are commonly found with proximal hypospadias and encompass a large spectrum, including ventral curvature (VC) up to 50 degrees or more, ventral skin deficiency, a flattened glans, penile torsion and penoscrotal transposition. Our contemporary understanding of hypospadiology is comprised of a foundation built by experts who have described a number of techniques and their outcomes, combined with survey data detailing practice patterns. The two largest components of hypospadias repair include repair of VC and urethroplasty. VC greater than 20 degrees is considered clinically relevant to warrant surgical correction. To repair VC, the penis is first degloved-a procedure that may reduce or remove curvature by itself in some cases. Residual curvature is then repaired with dorsal plication techniques, transection of the urethral plate, and/or ventral lengthening techniques. Urethroplasty takes the form of 1- or 2-stage repairs. One-stage options include the tubularized incised urethroplasty (TIP) or various graft or flap-based techniques. Two-stage options also include grafts or flaps, including oral mucosal and preputial skin grafting. One stage repairs are an attractive option in that they may reduce cost, hospital stay, anesthetic risks, and time to the final result. The downside is that these repairs require mastery of multiple techniques may be more complex, and-depending on technique-have higher complication rates. Two-stage repairs are preferred by the majority of surveyed hypospadiologists. The 2-stage repair is versatile and has satisfactory outcomes, but necessitates a second procedure. Given the lack of clear high-quality evidence supporting the

  11. HELQ promotes RAD51 paralogue-dependent repair to avert germ cell loss and tumorigenesis

    DEFF Research Database (Denmark)

    Adelman, Carrie A.; Lolo, Rafal L.; Birkbak, Nicolai Juul

    2013-01-01

    Repair of interstrand crosslinks (ICLs) requires the coordinated action of the intra-S-phase checkpoint and the Fanconi anaemia pathway, which promote ICL incision, translesion synthesis and homologous recombination (reviewed in refs 1, 2). Previous studies have implicated the 3'-5' superfamily 2......, phenotype than the null, indicative of haploinsufficiency. We establish that HELQ interacts directly with the RAD51 paralogue complex BCDX2 and functions in parallel to the Fanconi anaemia pathway to promote efficient homologous recombination at damaged replication forks. Thus, our results reveal a critical...

  12. Influence of different phacoemulsification incision on postoperative corneal astigmatism for cataract patients

    Directory of Open Access Journals (Sweden)

    Zhao-Rong Zeng

    2014-05-01

    Full Text Available AIM: To compare the effect of different phacoemulsification incision on postoperative corneal astigmatism for cataract patients. METHODS: The cataract patients were selected in our hospital. The patients were divided into control group(corneal limbus opposite curved scleral tunnel incision groupand observation group(above the top of cornea or temporal transparent corneal incision grouprandomly. At 1wk; 1 and 3mo after surgery, the change of corneal astigmatism and vision of the patients in two groups were compared and analyzed. RESULTS:Compared with control group, 1wk; 1 and 3mo after surgery, the average corneal astigmatism and surgically induced corneal astigmatism of the patients in observation group were decreased significantly. The visual acuity and corrected visual acuity were increased significantly. There was statistically significant(PPCONCLUSION: Center distance and small incision corneal phacoemulsification can reduce postoperative astigmatism and improve postoperative visual acuity for cataract patients. It provides guarantee for further strengthen the clinical treated effect for cataract patients.

  13. Single-cell gel electrophoresis applied to the analysis of UV-C damage and its repair in human cells

    International Nuclear Information System (INIS)

    Gedik, C.M.; Collins, A.R.; Ewen, S.W.B.

    1992-01-01

    The authors have adapted procedure of single cell gel electrophoresis (SCGE) for studying DNA damage and repair induced by UV-C-radiation, using HeLa cells. UV-C itself does not induce DNA breakage, and though cellular repair of UV-C damage produces DNA breaks as intermediates, these are too short-lived to be detected by SCGE. Incubation of UV-C-irradiated cells with the DNA synthesis inhibitor aphidicolin causes accumulation of incomplete repair sites to a level readily detected by SCGE even after doses as low as 0.5 J m -2 and incubation for as little as 5 min. The authors also studied UV-C-dependent incision, repair synthesis and ligation in permeable cells. Finally, key incubated permeable cells, after UV-C-irradiation, with exogenous UV endonuclease, examined consequent breaks both by SCGE and by alkaline unwinding to express results of the electrophoretic method in terms of DNA break frequencies. The sensitivity of the SCGE technique can thus be estimated; as few as 0.1 DNA breaks per 10 9 daltons are detected. (Author)

  14. What can we learn from fluvial incision in high mountains?

    Science.gov (United States)

    Fuchs, Margret; Gloaguen, Richard; Krbetschek, Matthias

    2013-04-01

    High and actively deforming mountain ranges attract the attention of geoscientists as they provide natural laboratories of fast evolving process-response systems. Tectonic compressional settings, often linked to perpendicular extension, control the topographic growth and hence, erosion, transport pathways and sedimentation. High altitude differences within short horizontal distances promote material re-organisation and high rates of surface processes. Furthermore, high mountains constitute orographic barriers that affect atmospheric circulations as well as host different climate regimes similar to those of widely separated latitudinal belts. Both cause a high sensitivity of surface processes to changes in climatic conditions. However, feedbacks between climatic and tectonic forcing are complex. Additionally, the dominance of one or the other varies in space and also over time, inheriting various traces of the paleo-morphodynamic conditions to the subsequent process regimes. To unravel the forces driving the evolution of relief in active mountains, numerous studies employ the drainage network of the corresponding mountains as a proxy of landscape evolution. Especially the rates of river incision provide a powerful tool to characterize the surface response and infer causes behind it. Several parameters of river incision are available to describe the fluvial incision at individual sites (e.g. terrace incision rates), along the river course (e.g. longitudinal river profiles, Hack index) and in its perpendicular dimension (e.g. valley cross sections, valley shape ratios). But they require careful interpretation. They are sensitive to both, climatic and tectonic forcing. Therefore, the synopsis of such indices for fluvial incision is essential to evaluate the role of climatic versus tectonic forcing. Here, we use the Panj river system, the major river draining the Pamir mountains of Central Asia, as an example. The Panj experiences high altitude changes of more than 4000

  15. Visible and NIR image fusion using weight-map-guided Laplacian ...

    Indian Academy of Sciences (India)

    Ashish V Vanmali

    fusion perspective, instead of the conventional haze imaging model. The proposed ... Image dehazing; Laplacian–Gaussian pyramid; multi-resolution fusion; visible–NIR image fusion; weight map. 1. .... Tan's [8] work is based on two assumptions: first, images ... responding colour image, since NIR can penetrate through.

  16. A Precise 6 Ma Start Date for Fluvial Incision of the Northeastern Colorado Plateau Canyonlands

    Science.gov (United States)

    Thomson, S. N.; Soreghan, G. S.; Reiners, P. W.; Peyton, S. L.; Murray, K. E.

    2015-12-01

    Outstanding questions regarding late Cenozoic Colorado Plateau landscape evolution include: (1) the relative roles of isostatic rebound as result Colorado River incision versus longer-term geodynamic processes in driving overall rock uplift of the plateau; and (2) whether incision was triggered by river integration or by a change in deep-seated mantle lithosphere dynamics. A key to answering these questions is to date more precisely the onset of incision to refine previous estimates of between 6 and 10 Ma. We present new low-temperature thermochronologic results from bedrock and deep borehole samples in the northeastern Colorado Plateau to show that rapid river incision began here at 6 Ma (5.93±0.66 Ma) with incision rates increasing from 15-50 m/Myr to 160-200 m/Myr. The onset time is constrained independently by both inverse time-temperature modeling and by the break-in-slope in fission track age-elevation relationships. This new time constraint has several important implications. First, the coincidence in time with 5.97-5.3 Ma integration of the lower Colorado River through the Grand Canyon to the Gulf of California strongly favors downstream river integration triggering carving of the canyonlands of the upper Colorado River system. Second, it implies integration of the entire Colorado River system in less than 2 million years. Third, rock uplift of the plateau driven by the flexural isostatic response to river incision is restricted to just the last 6 Ma, as is associated increased sediment budget. Fourth, incision starting at 6 Ma means that previous estimates of upper Colorado River incision rates based on 10-12 Ma basalt datum levels are too low. This also changes the dependency of measured time interval on incision rate from a non-steady-state negative power-law dependence (exponent of -0.24) to a near steady-state dependence (exponent of 0.07) meaning that long-term upper Colorado river incision rates can provide a reliable proxy for rock uplift rates.

  17. The Development of Novel Near-Infrared (NIR Tetraarylazadipyrromethene Fluorescent Dyes

    Directory of Open Access Journals (Sweden)

    Young-Tae Chang

    2013-05-01

    Full Text Available Novel structures of an near-infrared (NIR tetraarylazadipyrromethene (aza-BODIPY series have been prepared. We designed the core structure containing two amido groups at the para-position of the aromatic rings. The amido group was incorporated to secure insensitivity to pH and to ensure a bathochromic shift to the NIR region. Forty members of aza-BODIPY compounds were synthesized by substitution of the acetyl group with commercial amines on the alpha bromide. The physicochemical properties and photostability were investigated and the fluorescence emission maxima (745~755 nm were found to be in the near infrared (NIR range of fluorescence.

  18. A New Platform for Investigating In-Situ NIR Reflectance in Snow

    Science.gov (United States)

    Johnson, M.; Taubenheim, J. R. L.; Stevenson, R.; Eldred, D.

    2017-12-01

    In-situ near infrared (NIR) reflectance measurements of the snowpack have been shown to have correlations to valuable snowpack properties. To-date many studies take these measurements by digging a pit and setting up a NIR camera to take images of the wall. This setup is cumbersome, making it challenging to investigate things like spatial variability. Over the course of 3 winters, a new device has been developed capable of mitigating some of the downfalls of NIR open pit photography. This new instrument is a NIR profiler capable of taking NIR reflectance measurements without digging a pit, with most measurements taking less than 30 seconds to retrieve data. The latest prototype is built into a ski pole and automatically transfers data wirelessly to the users smartphone. During 2016-2017 winter, the device was used by 37 different users resulting in over 4000 measurements in the Western United States, demonstrating a dramatic reduction in time to data when compared to other methods. Presented here are some initial findings from a full winter of using the ski pole version of this device.

  19. Kualitas Pengeringan Kayu Mahoni pada Berbagai Variasi Kerapatan Incising dengan Dua Skedul Pengeringan Suhu tinggi

    Directory of Open Access Journals (Sweden)

    Tomy Listyanto

    2016-11-01

    Full Text Available Tujuan dari penelitian ini adalah untuk mengetahui pengaruh interaksi variasi kerapatan incising dan dua skedul pengeringan terhadap kecepatan dan cacat-cacat pengeringan kayu mahoni, serta mengetahui pengaruh variasi kerapatan incising terhadap kekuatan lengkung statik kayu mahoni yang telah dikeringkan. Tiga pohon mahoni (Swietenia mahagony berdiameter 300-350 mm ditebang dan selanjutnya dibelah dan dibuat menjadi balok dengan ukuran 60 mm × 100 mm dengan panjang 500 mm untuk dijadikan sampel pengeringan. Di antara masing-masing bagian tersebut, dibuat sampel ukuran 20 mm × 20 mm × 25 mm, yang digunakan untuk penentu kadar air awal dan distribusinya. Sampel pengeringan selanjutnya dibagi menjadi 5 variasi kerapatan incising, yaitu 0 lubang/m2 (tanpa incising, 1000 lubang/m2, 2000 lubang/m2, 3000 lubang/m2, dan 4000 lubang/m2. Setiap variasi kerapatan incising selanjutnya akan dikeringkan dengan 2 skedul pengeringan, yaitu suhu pengeringan 100°C sampai tercapai kadar air akhir 12% dan suhu 60°C pada 8 jam pertama dan selanjutnya dilanjutkan 100°C, sampai tercapai kadar air akhir 12%. Paramater yang diamati adalah kecepatan pengeringan, cacat retak permukaan, dan distribusi kadar air akhir. Hasil analisis menunjukkan bahwa kerapatan incising 3000-4000 lubang/m2 memberikan pengaruh yang cukup nyata di dalam mempercepat proses pengeringan dan distribusi kadar air akhir. Skedul pengeringan dan variasi kerapatan incising tidak berpengaruh pada retak permukaan. Pra perlakuan incising sampai batas 4000 lubang/m2 ini dapat diterapkan untuk mempercepat proses pengeringan dengan penurunan nilai modulus elastisitas dan modulus patah yang tidak berbeda nyata. Kata kunci: incising, pengeringan suhu tinggi, mahoni, lengkung statik, skedul pengeringan   Drying Quality of Mahoni Wood in Various Incising Densities and Two High Temperature-Drying Schedules Abstract The aims of this research were to investigate the effects of interaction

  20. Evaluation of a new disposable silicon limbal relaxing incision knife by experienced users

    Directory of Open Access Journals (Sweden)

    Parvu Valentin

    2009-12-01

    Full Text Available Abstract Background Previous research has suggested that the silicon BD Atomic Edge™ knife has superior performance characteristics when compared to a metal knife and performance similar to diamond knife when making various incisions. This study was designed to determine whether a silicon accurate depth knife has equivalent performance characteristics when compared to a diamond limbal relaxing incision (LRI knife and superior performance characteristics when compared to a steel accurate depth knife when creating limbal relaxing incision. Methods Sixty-five ophthalmic surgeons with limbal relaxing incision experience created limbal relaxing incisions in ex-vivo porcine eyes with silicon and steel accurate depth knives and diamond LRI knives. The ophthalmic surgeons rated multiple performance characteristics of the knives on Visual Analog Scales. Results The observed differences between the silicon knife and diamond knife were found to be insignificant. The mean ratio between the performance of the silicon knife and the diamond knife was shown to be greater than 90% (with 95% confidence. The silicon knife's mean performance was significantly higher than the performance of the steel knife for all characteristics. (p-value Conclusions For experienced users, the silicon accurate depth knife was found to be equivalent in performance to the diamond LRI knife and superior to the steel accurate depth knife when making limbal relaxing incisions in ex vivo porcine eyes. Disposable silicon LRI knives may be an alternative to diamond LRI knives.

  1. Supra-transumbilical laparotomy (STL approach for small bowel atresia repair: Our experience and review of the literature

    Directory of Open Access Journals (Sweden)

    Ernesto Leva

    2013-01-01

    Full Text Available Background: Supra-Transumbilical Laparotomy (STL has been used in paediatric surgery for a broad spectrum of abdominal procedures. We report our experience with STL approach for small bowel atresia repair in newborns and review previous published series on the topic. Patients and Methods: Fourteen patients with small bowel atresia were treated via STL approach at our Institution over a 5-year period and their charts were retrospectively reviewed. Results: STL procedure was performed at mean age of 3.1 day. No malrotation disorders were detected with pre-operative contrast enema. Eight patients (54.1% presented jejunal atresia, five (35.7% ileal atresia, and one (7.1% multiple ileal and jejunal atresias. Standard repair with primary end-to-back anastomosis was performed in all but one patient. In the newborn with multiple atresia, STL incision was converted in supra-umbilical transverse incision due to difficulty of exposition. After surgery, one patient developed anastomotic stricture, and another developed occlusion due to adhesions: Both infants required second laparotomy. No infections of the umbilical site were recorded, and cosmetic results were excellent in all patients. Conclusions: Increasing evidence suggests that STL approach for small bowel atresia is feasible, safe and provides adequate exposure for small bowel atresia surgery. When malrotation and colonic/multiple atresia are pre-operatively ruled out, STL procedure can be choosen as first approach.

  2. Simulation of channel sandstone architecture in an incised valley

    Energy Technology Data Exchange (ETDEWEB)

    Frykman, P.; Johannessen, P.; Andsbjerg, J.

    1998-12-31

    The present report describes a geostatistical modelling study that is aimed at reflecting the architecture of the channel sandstones in an incised valley fill. The example used for this study is a part of the Middle Jurassic sandy succession of the Bryne Formation in the Danish central Graben. The succession consists mainly of fluvial sediments in the lower part, overlain by tidal influenced sediments, which again is overlain by shallow marine sediments. The modelling study has been performed on a sequence of incised valley sediments in the upper part of the Bryne Formation overlying fluvial sediments. (au) EFP-96. 19 refs.

  3. Uptake of gallium-67 citrate in clean surgical incisions after colorectal surgery

    International Nuclear Information System (INIS)

    Lin Wanyu; Wang Shyhjen; Tsai Shihchuan; Chao Tehsin

    2001-01-01

    Non-specific accumulation of gallium-67 citrate (gallium) in uncomplicated surgical incisions is not uncommon. It is important to know the normal pattern of gallium uptake at surgical incision sites in order to properly interpret the gallium scan when investigating possible wound infection in patients who have undergone abdominal surgery. We studied 42 patients without wound infection after colorectal surgery and performed gallium scans within 40 days after surgery. Patients were divided into three groups according to the interval between the operation and the scan. In group A (26 patients) gallium scan was performed within 7 days after surgery, in group B (8 patients) between 8 and 14 days after surgery, and in group C (8 patients) between 15 and 40 days after surgery. Our data showed that in group A, 61.5% had gallium accumulation at the surgical incision site. In group B, 50% had accumulation of gallium at the surgical incision site, while in group C only one patient (12.5%) showed gallium uptake. It is concluded that the incidence of increased gallium uptake at clean surgical incision sites is high after colorectal surgery. Nuclear medicine physicians should bear in mind the high incidence of non-specific gallium uptake at such sites during the interpretation of possible wound infection in patients after colorectal surgery. (orig.)

  4. [Advances of NIR spectroscopy technology applied in seed quality detection].

    Science.gov (United States)

    Zhu, Li-wei; Ma, Wen-guang; Hu, Jin; Zheng, Yun-ye; Tian, Yi-xin; Guan, Ya-jing; Hu, Wei-min

    2015-02-01

    Near infrared spectroscopy (NIRS) technology developed fast in recent years, due to its rapid speed, less pollution, high-efficiency and other advantages. It has been widely used in many fields such as food, chemical industry, pharmacy, agriculture and so on. The seed is the most basic and important agricultural capital goods, and seed quality is important for agricultural production. Most methods presently used for seed quality detecting were destructive, slow and needed pretreatment, therefore, developing one kind of method that is simple and rapid has great significance for seed quality testing. This article reviewed the application and trends of NIRS technology in testing of seed constituents, vigor, disease and insect pests etc. For moisture, starch, protein, fatty acid and carotene content, the model identification rates were high as their relative contents were high; for trace organic, the identification rates were low as their relative content were low. The heat-damaged seeds with low vigor were discriminated by NIRS, the seeds stored for different time could also been identified. The discrimination of frost-damaged seeds was impossible. The NIRS could be used to identify health and infected disease seeds, and did the classification for the health degree; it could identify parts of the fungal pathogens. The NIRS could identify worm-eaten and health seeds, and further distinguished the insect species, however the identification effects for small larval and low injury level of insect pests was not good enough. Finally, in present paper existing problems and development trends for NIRS in seed quality detection was discussed, especially the single seed detecting technology which was characteristic of the seed industry, the standardization of its spectral acquisition accessories will greatly improve its applicability.

  5. Single-incision laparoscopic surgery through an ostomy site: a natural approach by an unnatural orifice.

    Science.gov (United States)

    Lopez, Nicole E; Peterson, Carrie Y; Ramamoorthy, Sonia L; McLemore, Elisabeth C; Sedrak, Michael F; Lowy, Andrew M; Horgan, Santiago; Talamini, Mark A; Sicklick, Jason K

    2015-02-01

    Single-incision laparoscopic surgery (SILS) is gaining popularity for a wide variety of surgical operations and capitalizes on the benefits of traditional laparoscopic surgery without incurring multiple incision sites. Traditionally, SILS is performed by a midline periumbilical approach. However, such a minimally invasive approach may be utilized in patients who already have an abdominal incision. Our series retrospectively reviews 7 cases in which we utilized the fascial defect at the time of after ostomy reversal as our SILS incision site. In turn, we performed a variety of concurrent intra-abdominal procedures with excellent technical success and outcomes. Our study is the largest single-institution case series of this novel approach and suggests that utilizing an existing ostomy-site abdominal incision is a safe and effective location for SILS port placement and should be considered in patients undergoing concurrent procedures.

  6. Steady incision of Grand Canyon at the million year timeframe: a case for mantle-driven differential uplift

    Science.gov (United States)

    Crow, Ryan S.; Karl Karlstrom,; Laura Crossey,; Richard Young,; Michael Ort,; Yemane Asmerom,; Victor Polyak,; Andrew Darling,

    2014-01-01

    The Grand Canyon region provides an excellent laboratory to examine the interplay between river incision, magmatism, and the geomorphic and tectonic processes that shape landscapes. Here we apply U-series, Ar–Ar, and cosmogenic burial dating of river terraces to examine spatial variations in incision rates along the 445 km length of the Colorado River through Grand Canyon. We also analyze strath terrace sequences that extend to heights of several hundred meters above the river, and integrate these with speleothem constrained maximum incision rates in several reaches to examine any temporal incision variations at the million-year time frame. This new high-resolution geochronology shows temporally steady long-term incision in any given reach of Grand Canyon but significant variations along its length from 160 m/Ma in the east to 101 m/Ma in the west. Spatial and temporal patterns of incision, and the long timescale of steady incision rule out models where geomorphic controls such as climate oscillations, bedrock strength, sediment load effects, or isostatic response to differential denudation are the first order drivers of canyon incision. The incision pattern is best explained by a model of Neogene and ongoing epeirogenic uplift due to an eastward propagating zone of increased upper mantle buoyancy that we infer from propagation of Neogene basaltic volcanism and a strong lateral gradient in modern upper mantle seismic structure.

  7. Arthroscopic Broström repair with Gould augmentation via an accessory anterolateral port for lateral instability of the ankle.

    Science.gov (United States)

    Matsui, Kentaro; Takao, Masato; Miyamoto, Wataru; Innami, Ken; Matsushita, Takashi

    2014-10-01

    Although several arthroscopic surgical techniques for the treatment of lateral instability of the ankle have been introduced recently, some concern remains over their procedural complexity, complications, and unclear clinical outcomes. We have simplified the arthroscopic technique of Broström repair with Gould augmentation. This technique requires only two small skin incisions for two ports (medial midline and accessory anterolateral ports), without needing a percutaneous procedure or extension of the skin incisions. The anterior talofibular ligament is reattached to its anatomical footprint on the fibula with suture anchor, under arthroscopic view. The inferior extensor retinaculum is directly visualized through the accessory anterolateral port and is attached to the fibula with another suture anchor under arthroscopic view via the anterolateral port. The use of two small ports offers a procedure that is simple to perform and less morbid for patients.

  8. Umbilical cord sparing technique for repair of congenital hernia into the cord and small omphalocele.

    Science.gov (United States)

    Ceccanti, Silvia; Falconi, Ilaria; Frediani, Simone; Boscarelli, Alessandro; Musleh, Layla; Cozzi, Denis A

    2017-01-01

    Current repair of small omphaloceles and hernias into the umbilical cord is a straightforward procedure, whose repair may result in a suboptimal cosmetic outcome. We describe a novel repair technique retaining the umbilical cord elements in an attempt to improve the cosmetic appearance of the umbilicus. Eight neonates were consecutively treated more than a ten-year period. Size of the fascial defects ranged 1 to 3cm (median, 2). Present technique entails incision of the amniotic sac without its detachment from the skin, reduction of the extruded contents under direct vision, and closure of the abdominal wall defect by circumferential suturing of peritoneum and fascia around the base of the amniotic sac. The amniotic sac is then re-approximated and folded to create an umbilical stump, which is trimmed and left to shed naturally. All patients achieved a scarless abdomen with a normal appearing umbilicus in 6. The remaining 2 patients are awaiting surgery for persisting umbilical hernia repair and umbilicoplasty, respectively. Poor esthetic outcome was significantly associated with initial fascial defect ≥2.5cm in size (p=0.03). Present technique is a simple and cosmetically appealing repair for umbilical cord hernias and small omphaloceles, especially effective when the size of the fascial defect is less than 2.5cm. IV (Treatment Study). Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Efficiency of soft tissue incision with a novel 445-nm semiconductor laser.

    Science.gov (United States)

    Braun, Andreas; Kettner, Moritz; Berthold, Michael; Wenzler, Johannes-Simon; Heymann, Paul Günther Baptist; Frankenberger, Roland

    2018-01-01

    Using a 445-nm semiconductor laser for tissue incision, an effective cut is expected due to the special absorption properties of blue laser light in soft tissues. The aim of the present study was the histological evaluation of tissue samples after incision with a 445-nm diode laser. Forty soft tissue specimens were obtained from pork oral mucosa and mounted on a motorized linear translation stage. The handpiece of a high-frequency surgery device, a 970-nm semiconductor laser, and a 445-nm semiconductor laser were connected to the slide, allowing a constant linear movement (2 mm/s) and the same distance of the working tip to the soft tissue's surface. Four incisions were made each: (I) 970-nm laser with conditioned fiber tip, contact mode at 3-W cw; (II-III): 445-nm laser with non-conditioned fiber tip, contact mode at 2-W cw, and non-contact mode (1 mm) at 2 W; and (IV): high-frequency surgery device with straight working tip, 90° angulation, contact mode at 50 W. Histological analysis was performed after H&E staining of the embedded specimens at 35-fold magnification. The comparison of the incision depths showed a significant difference depending on the laser wavelength and the selected laser parameters. The highest incision depth was achieved with the 445-nm laser contact mode (median depth 0.61 mm, min 0.26, max 1.17, interquartile range 0.58) (p laser, a higher cutting efficiency can be expected when compared with a 970-nm diode laser and high-frequency surgery. Even the 445-nm laser application in non-contact mode shows clinically acceptable incision depths without signs of extensive soft tissue denaturation.

  10. Incision and stress regulation in borderline personality disorder: neurobiological mechanisms of self-injurious behaviour.

    Science.gov (United States)

    Reitz, Sarah; Kluetsch, Rosemarie; Niedtfeld, Inga; Knorz, Teresa; Lis, Stefanie; Paret, Christian; Kirsch, Peter; Meyer-Lindenberg, Andreas; Treede, Rolf-Detlef; Baumgärtner, Ulf; Bohus, Martin; Schmahl, Christian

    2015-08-01

    Patients with borderline personality disorder frequently show non-suicidal self-injury (NSSI). In these patients, NSSI often serves to reduce high levels of stress. Investigation of neurobiological mechanisms of NSSI in borderline personality disorder. In total, 21 women with borderline personality disorder and 17 healthy controls underwent a stress induction, followed by either an incision into the forearm or a sham treatment. Afterwards participants underwent resting-state functional magnetic resonance imaging while aversive tension, heart rate and heart rate variability were assessed. We found a significant influence of incision on subjective and objective stress levels with a stronger decrease of aversive tension in the borderline personality disorder group following incision than sham. Amygdala activity decreased more and functional connectivity with superior frontal gyrus normalised after incision in the borderline personality disorder group. Decreased stress levels and amygdala activity after incision support the assumption of an influence of NSSI on emotion regulation in individuals with borderline personality disorder and aids in understanding why these patients use self-inflicted pain to reduce inner tension. © The Royal College of Psychiatrists 2015.

  11. Toward Adaptation of fNIRS Instrumentation to Airborne Environments

    Science.gov (United States)

    Adamovsky, Grigory; Mackey, Jeffrey; Harrivel, Angela; Hearn, Tristan; Floyd, Bertram

    2014-01-01

    The paper reviews potential applications of functional Near-Infrared Spectroscopy (fNIRS), a well-known medical diagnostic technique, to monitoring the cognitive state of pilots with a focus on identifying ways to adopt this technique to airborne environments. We also discuss various fNIRS techniques and the direction of technology maturation of associated hardware in view of their potential for miniaturization, maximization of data collection capabilities, and user friendliness.

  12. A single incision transaxillary thoracoscopic sympathectomy

    Directory of Open Access Journals (Sweden)

    Marić Nebojša

    2014-01-01

    Full Text Available Background/Aim. Primary hyperhidrosis causes are unknown. The disorder begins in early childhood. It intensifies in puberty and maturity. It is equally present in both sexes. The symptoms exacerbate when the body temperature rises and due to emotional stimuli affecting the sympathetic nerve system. The aim of this study was to demonstrate that videoassisted thoracoscopic surgery (VATS sympathectomy is a method for primary focal hyperhidrosis permanent treatment. The single incision method in properly selected patients maximizes the intervention effectiveness and minimizes aesthetic side effects. Methods. This prospective study analysed the findings in patients who had been operated on due to primary focal hyperhidrosis (face, palms, and armpits using a single small transaxilarry incision in the third inter-rib space at the level of the anterior axillary line with two 5 mm flexible ports. All the patients, with T2-T5 thoracoscopic sympathectomy of the sympathetic chain using a single small incision in the third inter-rib space in the anterior axillary line, were analysed in the period from September 2009 to November 2010 regarding the postoperative morbidity and outcomes of the operation (clinical evaluation and visual analogue scale with a view to assessing the effectiveness of the surgery conducted in this manner. Results. A total of 47 patients (18 men, 29 women, 18 to 48 years old (29 on average had underwent 94 bilateral video-assisted thoracoscopic sympathectomies. The sympathectomy was indicated in cases of facial blushing and sweating (6.38%, palmary sweating (34.04%, axillary sweating (14.89% or both palmary and axillary sweating (44.68%. The largest percentage of patients (98.6% had left the hospital the following day. The postoperative 30 day’s mortality was 0 and the conversion into open surgery was not necessary. As for complications, there had been an occurrence of partial pneumothorax in two patients treated by means of

  13. Ultrasonographic evaluation of the healing of ventral midline abdominal incisions in the horse.

    Science.gov (United States)

    Wilson, D A; Badertscher, R R; Boero, M J; Baker, G J; Foreman, J H

    1989-06-01

    Ultrasonography was used to evaluate the ventral midline incisions of 21 ponies following exploratory laparotomy. The incisions were evaluated before surgery and at weekly intervals from one to seven weeks after surgery. Both 5.0 and 7.5 MHz linear array and 7.5 MHz sector transducers were used for the evaluations. The incisional complications observed were drainage, oedema, suture sinus formation, suture abscess, superficial dehiscence and incisional hernia. Ultrasonographic imaging of the ventral midline incision was an easy, reliable and objective method for detecting and monitoring the progression of incisional complications in a non-invasive manner.

  14. Turbine repair process, repaired coating, and repaired turbine component

    Science.gov (United States)

    Das, Rupak; Delvaux, John McConnell; Garcia-Crespo, Andres Jose

    2015-11-03

    A turbine repair process, a repaired coating, and a repaired turbine component are disclosed. The turbine repair process includes providing a turbine component having a higher-pressure region and a lower-pressure region, introducing particles into the higher-pressure region, and at least partially repairing an opening between the higher-pressure region and the lower-pressure region with at least one of the particles to form a repaired turbine component. The repaired coating includes a silicon material, a ceramic matrix composite material, and a repaired region having the silicon material deposited on and surrounded by the ceramic matrix composite material. The repaired turbine component a ceramic matrix composite layer and a repaired region having silicon material deposited on and surrounded by the ceramic matrix composite material.

  15. Processing closely spaced lesions during Nucleotide Excision Repair triggers mutagenesis in E. coli

    Science.gov (United States)

    Isogawa, Asako; Fujii, Shingo

    2017-01-01

    It is generally assumed that most point mutations are fixed when damage containing template DNA undergoes replication, either right at the fork or behind the fork during gap filling. Here we provide genetic evidence for a pathway, dependent on Nucleotide Excision Repair, that induces mutations when processing closely spaced lesions. This pathway, referred to as Nucleotide Excision Repair-induced Mutagenesis (NERiM), exhibits several characteristics distinct from mutations that occur within the course of replication: i) following UV irradiation, NER-induced mutations are fixed much more rapidly (t ½ ≈ 30 min) than replication dependent mutations (t ½ ≈ 80–100 min) ii) NERiM specifically requires DNA Pol IV in addition to Pol V iii) NERiM exhibits a two-hit dose-response curve that suggests processing of closely spaced lesions. A mathematical model let us define the geometry (infer the structure) of the toxic intermediate as being formed when NER incises a lesion that resides in close proximity of another lesion in the complementary strand. This critical NER intermediate requires Pol IV / Pol II for repair, it is either lethal if left unrepaired or mutation-prone when repaired. Finally, NERiM is found to operate in stationary phase cells providing an intriguing possibility for ongoing evolution in the absence of replication. PMID:28686598

  16. [A modified Onizuka cheiloplasty for repairing the unilateral cleft lip].

    Science.gov (United States)

    Zhang, Bin; Wang, Chao; Liu, Qiang; Li, Zengjian; Xu, Xianyi

    2011-08-01

    To explore the surgical technique of a modified Onizuka cheiloplasty for repairing the unilateral cleft lip. 24 patients with unilateral cleft lip were repaired by modified Onizuka cheiloplasty. The rotation flap ended at the midpoint of nasal columella crease. A small triangle skin flap was formed above the vermilion border of the advancement flap. The small triangle flap was inserted to the medial side after the Cupid's bow was built. The skin of the flap C was denuded along the nasal columella crease and the muscle was sutured to the alar base for augmentation of nostril floor on the cleft side. The tip of the advancement flap was sutured at the midpoint of nasal columella crease and the skin of nasal floor was trimmed to hide the incision line around the nasal columella base. It was found that the Cupid's bow was rebuilt in a natural form and the configuration of the upper lip was reconstructed symmetrically. The long term follow up studies showed that the philtrum column was not disturbed by the small triangle flap and the nasal floor was rebuilt without obvious scars. The modified Onizuka cheiloplasty is an easy learning technique and efficient for repairing the unilateral cleft lip. This technique can satisfy the patients by reducing the length of scar as well as rebuilding a natural form of upper lip and nostril floor.

  17. Panoramic radiographs underestimate extensions of the anterior loop and mandibular incisive canal

    International Nuclear Information System (INIS)

    De Brito, Ana Caroline Ramos; Nejaim, Yuri; De Freitas, Deborah Queiroz; De Oliveira Santos, Christiano

    2016-01-01

    The purpose of this study was to detect the anterior loop of the mental nerve and the mandibular incisive canal in panoramic radiographs (PAN) and cone-beam computed tomography (CBCT) images, as well as to determine the anterior/mesial extension of these structures in panoramic and cross-sectional reconstructions using PAN and CBCT images. Images (both PAN and CBCT) from 90 patients were evaluated by 2 independent observers. Detection of the anterior loop and the incisive canal were compared between PAN and CBCT. The anterior/mesial extension of these structures was compared between PAN and both cross-sectional and panoramic CBCT reconstructions. In CBCT, the anterior loop and the incisive canal were observed in 7.7% and 24.4% of the hemimandibles, respectively. In PAN, the anterior loop and the incisive canal were detected in 15% and 5.5% of cases, respectively. PAN presented more difficulties in the visualization of structures. The anterior/mesial extensions ranged from 0.0 mm to 19.0 mm on CBCT. PAN underestimated the measurements by approximately 2.0 mm. CBCT appears to be a more reliable imaging modality than PAN for preoperative workups of the anterior mandible. Individual variations in the anterior/mesial extensions of the anterior loop of the mental nerve and the mandibular incisive canal mean that is not prudent to rely on a general safe zone for implant placement or bone surgery in the interforaminal region

  18. Panoramic radiographs underestimate extensions of the anterior loop and mandibular incisive canal

    Energy Technology Data Exchange (ETDEWEB)

    De Brito, Ana Caroline Ramos; Nejaim, Yuri; De Freitas, Deborah Queiroz [Dept. of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Sao Paulo (Brazil); De Oliveira Santos, Christiano [Dept. of Stomatology, Public Oral Health and Forensic Dentistry, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Sao Paulo (Brazil)

    2016-09-15

    The purpose of this study was to detect the anterior loop of the mental nerve and the mandibular incisive canal in panoramic radiographs (PAN) and cone-beam computed tomography (CBCT) images, as well as to determine the anterior/mesial extension of these structures in panoramic and cross-sectional reconstructions using PAN and CBCT images. Images (both PAN and CBCT) from 90 patients were evaluated by 2 independent observers. Detection of the anterior loop and the incisive canal were compared between PAN and CBCT. The anterior/mesial extension of these structures was compared between PAN and both cross-sectional and panoramic CBCT reconstructions. In CBCT, the anterior loop and the incisive canal were observed in 7.7% and 24.4% of the hemimandibles, respectively. In PAN, the anterior loop and the incisive canal were detected in 15% and 5.5% of cases, respectively. PAN presented more difficulties in the visualization of structures. The anterior/mesial extensions ranged from 0.0 mm to 19.0 mm on CBCT. PAN underestimated the measurements by approximately 2.0 mm. CBCT appears to be a more reliable imaging modality than PAN for preoperative workups of the anterior mandible. Individual variations in the anterior/mesial extensions of the anterior loop of the mental nerve and the mandibular incisive canal mean that is not prudent to rely on a general safe zone for implant placement or bone surgery in the interforaminal region.

  19. Linear regression models and k-means clustering for statistical analysis of fNIRS data.

    Science.gov (United States)

    Bonomini, Viola; Zucchelli, Lucia; Re, Rebecca; Ieva, Francesca; Spinelli, Lorenzo; Contini, Davide; Paganoni, Anna; Torricelli, Alessandro

    2015-02-01

    We propose a new algorithm, based on a linear regression model, to statistically estimate the hemodynamic activations in fNIRS data sets. The main concern guiding the algorithm development was the minimization of assumptions and approximations made on the data set for the application of statistical tests. Further, we propose a K-means method to cluster fNIRS data (i.e. channels) as activated or not activated. The methods were validated both on simulated and in vivo fNIRS data. A time domain (TD) fNIRS technique was preferred because of its high performances in discriminating cortical activation and superficial physiological changes. However, the proposed method is also applicable to continuous wave or frequency domain fNIRS data sets.

  20. Mini- or Less-open Sublay Operation (MILOS): A New Minimally Invasive Technique for the Extraperitoneal Mesh Repair of Incisional Hernias.

    Science.gov (United States)

    Reinpold, Wolfgang; Schröder, Michael; Berger, Cigdem; Nehls, Jennifer; Schröder, Alexander; Hukauf, Martin; Köckerling, Ferdinand; Bittner, Reinhard

    2018-01-16

    Improvement of ventral hernia repair. Despite the use of mesh and other recent improvements, the currently popular techniques of ventral hernia repair have specific disadvantages and risks. We developed the endoscopically assisted mini- or less-open sublay (MILOS) concept. The operation is performed transhernially via a small incision with light-holding laparoscopic instruments either under direct, or endoscopic visualization. An endoscopic light tube was developed to facilitate this approach (EndotorchTM Wolf Company). Each MILOS operation can be converted to standard total extraperitoneal gas endoscopy once an extraperitoneal space of at least 8 cm has been created. All MILOS operations were prospectively documented in the German Hernia registry with 1 year questionnaire follow-up. Propensity score matching of incisional hernia operations comparing the results of the MILOS operation with the laparoscopic intraperitoneal onlay mesh operation (IPOM) and open sublay repair from other German Hernia registry institutions was performed. Six hundred fifteen MILOS incisional hernia operations were included. Compared with laparoscopic IPOM incisional hernia operation, the MILOS repair is associated with significantly a fewer postoperative surgical complications (P advantages of open sublay and the laparoscopic IPOM repair.ClinicalTrials.gov Identifier NCT03133000.

  1. 2D Vis/NIR correlation spectroscopy of cooked chicken meats

    Science.gov (United States)

    Liu, Yongliang; Chen, Yud-Ren; Ozaki, Yukihiro

    2000-03-01

    Cooking of chicken meats was investigated by the generalized two-dimensional visible/near-infrared (2D Vis/NIR) correlation spectroscopy. Synchronous and asynchronous spectra in the 400-700 nm visible region suggested that the 445 and 560 nm bands be ascribed to deoxymyoglobin and oxymyoglobin, and at least one of the 475, 520, and 585 nm bands is assignable to the denatured species (metmyoglobin). The asynchronous 2D NIR correlation spectrum showed that CH bands change their spectral intensities before the OH/NH groups during the cooking process, indicating that CH fractions are easily oxidized and degraded. In addition, strong correlation peaks were observed correlating the bands in the visible and NIR spectral regions.

  2. Better outcome from arthroscopic partial meniscectomy than skin incisions only?

    DEFF Research Database (Denmark)

    Roos, Ewa M; Hare, Kristoffer Borbjerg; Nielsen, Sabrina Mai

    2018-01-01

    . In total, nine participants experienced 11 adverse events; six in the surgery group and three in the skin-incisions-only group. CONCLUSION: We found greater improvement from arthroscopic partial meniscectomy compared with skin incisions only at 2 years, with the statistical uncertainty of the between......-group difference including what could be considered clinically relevant. Because of the study being underpowered, nearly half in the sham group being non-blinded and one-third crossing over to surgery, the results cannot be generalised to the greater patient population. TRIAL REGISTRATION NUMBER: NCT01264991....

  3. NIR Techniques Create Added Values for the Pellet and Biofuel Industry

    Energy Technology Data Exchange (ETDEWEB)

    Lestander, Torbjoern A. [Swedish Univ of Agricultural Science, Umeaa (Sweden). Unit of Biomass Technology and Chemistry; Johnsson, Bo; Grothage, Morgan [Casco Adhesives AB, Sundsvall (Sweden)

    2006-07-15

    Pelletizing of biomass as biofuels increases energy density, improves storability and reduces transport costs. This process is a major key factor in the transition from fossil fuels to renewable biomass refined as solid biofuels. The fast growing pellet industry is today producing more than 1.2 Gg wood Pellets in Sweden - one of the leading nations to utilize bioenergy in its energy mix. The multitude of raw biomaterials available for fuel pellet production and their widely different characteristics stress the need for rapid characterization methods. A suitable technique for characterization of variation in biomaterials is near infrared (NIR) spectrometry. NIR radiation interacts with polar molecules and especially with structural groups O-H as in water, C-H as in biomass, but also with C-O bonds and C=C double bonds frequently found in biomass. Biomass contains mostly the atoms C, O and H. This means that transmittance or reflectance in the NIR wavelength region covers most of the covalent bonds in biomass, except for the C-C bonds in carbon chains. The NIR technique is also developed for on-line measurement in harsh industrial conditions. Thus, NIR techniques can be applied for on-line and real time characterization of raw biomass as well as in the refinement process of biomass into standardized solid biofuels. Spectral patterns in the NIR region contain chemical and physical information structure that together with reference parameters can be modeled by multivariate calibration methods to obtain predictions. These predictions can be presented to the operators in real time on screens as charts based on multivariate statistical process controls. This improves the possibilities to overview the raw biomass variation and to control the responses of the treatments the biomass undergo in the pelletizing process. The NIR-technique is exemplified by a 23-factorial experiment that was carried out in a pellet plant using sawdust as raw material to produce wood Pellets as

  4. [Induction and analysis for NIR features of frequently-used mineral traditional Chinese medicines].

    Science.gov (United States)

    Chen, Long; Yuan, Ming-Yang; Chen, Ke-Li

    2016-10-01

    In order to provide theoretical basis for the rapid identification of mineral traditional Chinese medicines(TCM) with near infrared (NIR)diffuse reflectance spectroscopy, Characteristic NIR spectra of 51 kinds of mineral TCMs were generalized and compared on the basis of the previous research, and the characteristic spectral bands were determined and analyzed by referring to mineralogical and geological literatures. It turned out that the NIR features of mineral TCMs were mainly at 8 000-4 000 cm ⁻¹ wavebands, which can be assigned as the absorption of water, -OH and[CO3 ²⁻] and so on. Absorption peaks of water has regularity as follows, the structure water and -OH had a combined peak which was strong and keen-edged around 7 000 cm ⁻¹, the crystal water had two strong peak around 7 000 cm ⁻¹ and 5 100 cm ⁻¹, and water only has a broad peak around 5 100 cm ⁻¹. Due to the differences in the crystal form and the contents of water in mineral TCMs, NIR features of water in mineral TCMs which could be used for identification were different. Mineral TCMs containing sulfate are rich in crystal water, mineral TCMs containing silicate generally had structure water, and mineral TCMs containing carbonate merely had a little of water, so it was reasonable for the use of NIR spectroscopy to classify mineral TCMs with anionic type. In addition, because of the differences in cationic type, impurities, crystal form and crystallinity, mineral TCMs have exclusive NIR features at 4 600-4 000 cm ⁻¹, which can be assigned as Al-OH, Mg-OH, Fe-OH, Si-OH,[CO3 ²⁻] and so on. Calcined mineral TCMs are often associated with water and main composition changes, also changes of the NIR features, which could be used for the monitoring of the processing, and to provide references for the quality control of mineral TCMs. The adaptability and limitation of NIR analysis for mineral TCMs were also discussed:the majority of mineral TCMs had noteworthy NIR features which could be

  5. Phage T4 endonuclease V stimulates DNA repair replication in isolated nuclei from ultraviolet-irradiated human cells, including xeroderma pigmentosum fibroblasts

    International Nuclear Information System (INIS)

    Smith, C.A.; Hanawalt, P.C.

    1978-01-01

    The repair mode of DNA replication has been demonstrated in isolated nuclei from uv-irradiated human cells. Nuclei are incubated in a mixture containing [ 3 H]thymidine triphosphate and bromodeoxyuridine triphosphate in a 1:5 ratio. The 3 H at the density of parental DNA in alkaline CsCl density gradients is then a measure of repair. In nuclei prepared from WI38 cells 30 min after irradiation, repair replication is uv-dependent and proceeds at approximately the in vivo rate for 5 min. Repair replication is reduced in irradiated nuclei or in nuclei prepared immediately after irradiation. It is Mg 2+ -dependent and stimulated by added ATP and deoxyribonucleoside triphosphates. No repair replication is observed in nuclei from xeroderma pigmentosum (complementation group A) cells. However, upon addition of coliphage T4 endonuclease V, which specifically nicks DNA containing pyrimidine dimers, repair replication is observed in nuclei from irradiated xeroderma pigmentosum cells and is stimulated in WI38 nuclei. The reaction then persists for an hour and is dependent upon added ATP and deoxyribonucleoside triphosphates. The repair label is in stretches of roughly 35 nucleotides, as it is in intact cells. Added pancreatic DNase does not promote uv-dependent repair synthesis. Our results support the view that xeroderma pigmentosum (group A) cells are defective in the incision step of the DNA excision repair pathway, and demonstrate the utility of this system for probing DNA repair mechanisms

  6. The "Propeller" incision for transpalatal advancement pharyngoplasty: a new approach to reduce post-operative oronasal fistulae.

    Science.gov (United States)

    Shine, Neville Patrick; Lewis, Richard Hamilton

    2008-09-01

    To present a new soft tissue approach for transpalatal advancement pharyngoplasty (TPA), the propeller incision, and to compare the rates of post-operative oronasal fistula in those undergoing TPA with the traditional "Gothic Arch" incision described by Woodson and those with the propeller incision. A prospectively maintained adult sleep apnoea surgery database was used to identify those patients undergoing TPA, either alone or in combination with other procedures, for obstructive sleep apnoea syndrome (OSAS) between February 2001 and September 2006 in a tertiary referral centre by a single surgeon (RHL). In addition to the incision used during TPA, patient demographic data, previous surgery of the upper airways, smoking history, pre-operative body mass index, respiratory disturbance index, oxygen saturation index and the occurrence of oronasal fistula post-operatively, were recorded. The propeller incision technique is described. A total of 89 patients who underwent TPA were identified. A total of 49 patients had a "Gothic Arch" incision and 40 had a "Propeller" incision. The two groups of patients were comparable in age, sex, previous tonsillar and uvulopalatopharyngoplasty surgery, smoking histories and pre-operative disease severity. In the "Gothic Arch" group, eight patients (16%) developed oronasal fistulae in the post-operative period versus only one patient (2.5%) in the "Propeller" group. The difference between the two groups was statistically significant (P=0.038, Fisher's exact test). Of the total cases with post-operative oronasal fistula (n=9), only one patient (from the Gothic Arch incision group) required operative closure which was performed under local anesthesia and healed without complication. The propeller incision provides an anatomically sensible axial-based flap that provides adequate access to perform TPA. It is associated with a lower incidence of oronasal fistula and is recommended by the authors.

  7. Repair of UV damage in Escherichia coli under non-growth conditions

    International Nuclear Information System (INIS)

    Tang, M.-S.; Patrick, M.H.

    1977-01-01

    A large difference in survival occurred between buffered suspensions of E.coli irradiated with UV radiation at a low fluence rate and those irradiated at a high fluence rate. For sufficiently large fluences, the extent of this fluence rate dependent recovery (FRR) was about two orders of magnitude greater than that which could be brought about by liquid holding recovery (LHR) following high fluence rate irradiation in most of the E.coli strains studied. LHR and FRR occurred in excision resynthesis repair proficient (ERR + ) but not ERR - strains of E.coli, although its observation could be masked in strains with complete repair potential upon subsequent growth on nutrient plates. Accumulation of DNA strand interruptions and excision of cyclobutyl dipyrimidine occurred during LHR and FRR but were more extensive for the latter. The data suggest that events beyond incision and excision occurred during LHR and FRR, but differences in the extent of ERR during LHR and FRR could not account for the difference in cell survival between these two phenomena. (author)

  8. Repair of uv damage in Escherichia coli under non-growth conditions

    Energy Technology Data Exchange (ETDEWEB)

    Tang, M S; Patrick, M H [Texas Univ., Dallas (USA)

    1977-09-01

    A large difference in survival occurred between buffered suspensions of E.coli irradiated with uv radiation at a low fluence rate and those irradiated at a high fluence rate. For sufficiently large fluences, the extent of this fluence rate dependent recovery (FRR) was about two orders of magnitude greater than that which could be brought about by liquid holding recovery (LHR) following high fluence rate irradiation in most of the E.coli strains studied. LHR and FRR occurred in excision resynthesis repair proficient (ERR/sup +/) but not ERR/sup -/ strains of E.coli, although its observation could be masked in strains with complete repair potential upon subsequent growth on nutrient plates. Accumulation of DNA strand interruptions and excision of cyclobutyl dipyrimidine occurred during LHR and FRR but were more extensive for the latter. The data suggest that events beyond incision and excision occurred during LHR and FRR, but differences in the extent of ERR during LHR and FRR could not account for the difference in cell survival between these two phenomena.

  9. No difference in incidence of port-site hernia and chronic pain after single-incision laparoscopic cholecystectomy versus conventional laparoscopic cholecystectomy

    DEFF Research Database (Denmark)

    Christoffersen, Mette W; Brandt, Erik; Oehlenschläger, Jacob

    2015-01-01

    and matched 1:2 with patients subjected to CLC using pre-defined criteria. Follow-up data were obtained from the Danish National Patient Registry, mailed patient questionnaires, and clinical examination. A port-site hernia was defined as a repair for a port-site hernia or clinical hernia located at one......BACKGROUND: Conventional laparoscopic cholecystectomy (CLC) is regarded as the gold standard for cholecystectomy. However, single-incision laparoscopic cholecystectomy (SLC) has been suggested to replace CLC. This study aimed at comparing long-term incidences of port-site hernia and chronic pain...... after SLC versus CLC. METHODS: We conducted a matched cohort study based on prospective data (Jan 1, 2009-June 1, 2011) from the Danish Cholecystectomy Database with perioperative information and clinical follow-up. Consecutive patients undergoing elective SLC during the study period were included...

  10. Hybrid EEG-fNIRS Asynchronous Brain-Computer Interface for Multiple Motor Tasks.

    Directory of Open Access Journals (Sweden)

    Alessio Paolo Buccino

    Full Text Available Non-invasive Brain-Computer Interfaces (BCI have demonstrated great promise for neuroprosthetics and assistive devices. Here we aim to investigate methods to combine Electroencephalography (EEG and functional Near-Infrared Spectroscopy (fNIRS in an asynchronous Sensory Motor rhythm (SMR-based BCI. We attempted to classify 4 different executed movements, namely, Right-Arm-Left-Arm-Right-Hand-Left-Hand tasks. Previous studies demonstrated the benefit of EEG-fNIRS combination. However, since normally fNIRS hemodynamic response shows a long delay, we investigated new features, involving slope indicators, in order to immediately detect changes in the signals. Moreover, Common Spatial Patterns (CSPs have been applied to both EEG and fNIRS signals. 15 healthy subjects took part in the experiments and since 25 trials per class were available, CSPs have been regularized with information from the entire population of participants and optimized using genetic algorithms. The different features have been compared in terms of performance and the dynamic accuracy over trials shows that the introduced methods diminish the fNIRS delay in the detection of changes.

  11. Crystal structure of a Fanconi anemia-associated nuclease homolog bound to 5' flap DNA: basis of interstrand cross-link repair by FAN1

    Energy Technology Data Exchange (ETDEWEB)

    Gwon, Gwang Hyeon; Kim, Youngran; Liu, Yaqi; Watson, Adam T.; Jo, Aera; Etheridge, Thomas J.; Yuan, Fenghua; Zhang, Yanbin; Kim, YoungChang; Carr, Anthony M.; Cho, Yunje

    2014-10-15

    Fanconi anemia (FA) is an autosomal recessive genetic disorder caused by defects in any of 15 FA genes responsible for processing DNA interstrand cross-links (ICLs). The ultimate outcome of the FA pathway is resolution of cross-links, which requires structure-selective nucleases. FA-associated nuclease 1 (FAN1) is believed to be recruited to lesions by a monoubiquitinated FANCI–FANCD2 (ID) complex and participates in ICL repair. Here, we determined the crystal structure of Pseudomonas aeruginosa FAN1 (PaFAN1) lacking the UBZ (ubiquitin-binding zinc) domain in complex with 5' flap DNA. All four domains of the right-hand-shaped PaFAN1 are involved in DNA recognition, with each domain playing a specific role in bending DNA at the nick. The six-helix bundle that binds the junction connects to the catalytic viral replication and repair (VRR) nuclease (VRR nuc) domain, enabling FAN1 to incise the scissile phosphate a few bases distant from the junction. The six-helix bundle also inhibits the cleavage of intact Holliday junctions. PaFAN1 shares several conserved features with other flap structure-selective nucleases despite structural differences. A clamping motion of the domains around the wedge helix, which acts as a pivot, facilitates nucleolytic cleavage. The PaFAN1 structure provides insights into how archaeal Holliday junction resolvases evolved to incise 5' flap substrates and how FAN1 integrates with the FA complex to participate in ICL repair.

  12. Heterologous expression of the Aspergillus nidulans regulatory gene nirA in Fusarium oxysporum.

    Science.gov (United States)

    Daboussi, M J; Langin, T; Deschamps, F; Brygoo, Y; Scazzocchio, C; Burger, G

    1991-12-20

    We have isolated strains of Fusarium oxysporum carrying mutations conferring a phenotype characteristic of a loss of function in the regulatory gene of nitrate assimilation (nirA in Aspergillus nidulans, nit-4 in Neurospora crassa). One of these nir- mutants was successfully transformed with a plasmid containing the nirA gene of A. nidulans. The nitrate reductase of the transformants is still inducible, although the maximum activity is lower than in the wild type. Single and multiple integration events were found, as well as a strict correlation between the presence of the nirA gene and the Nir+ phenotype of the F. oxysporum transformants. We also investigated how the A. nidulans structural gene (niaD) is regulated in F. oxysporum. Enzyme assays and Northern experiments show that the niaD gene is subject to nitrate induction and that it responds to nitrogen metabolite repression in a F. oxysporum genetic background. This indicates that both the mechanisms of specific induction, mediated by a gene product isofunctional to nirA, and nitrogen metabolite repression, presumably mediated by a gene product isofunctional to the homologous gene of A. nidulans, are operative in F. oxysporum.

  13. Estimation of Sensory Analysis Cupping Test Arabica Coffee Using NIR Spectroscopy

    Science.gov (United States)

    Safrizal; Sutrisno; Lilik, P. E. N.; Ahmad, U.; Samsudin

    2018-05-01

    Flavors have become the most important coffee quality parameters now day, many coffee consuming countries require certain taste scores for the coffee to be ordered, the currently used cupping method of appraisal is the method designed by The Specialty Coffee Association Of America (SCAA), from several previous studies was found that Near-Infrared Spectroscopy (NIRS) can be used to detect chemical composition of certain materials including those associated with flavor so it is possible also to be applied to coffee powder. The aim of this research is to get correlation between NIRS spectrum with cupping scoring by tester, then look at the possibility of testing coffee taste sensors using NIRS spectrum. The coffee samples were taken from various places, altitudes and postharvest handling methods, then the samples were prepared following the SCAA protocol, for sensory analysis was done in two ways, with the expert tester and with the NIRS test. The calibration between both found that Without pretreatment using PLS get RMSE cross validation 6.14, using Multiplicative Scatter Correction spectra obtained RMSE cross validation 5.43, the best RMSE cross-validation was 1.73 achieved by de-trending correction, NIRS can be used to predict the score of cupping.

  14. Single-incision laparoscopic bariatric surgery

    Directory of Open Access Journals (Sweden)

    Huang Chih-Kun

    2011-01-01

    Full Text Available Background: Bariatric surgery has been established as the best option of treatment for morbid obesity. In recent years single-incision laparoscopic surgery (SILS has emerged as another modality of carrying out the bariatric procedures. While SILS represents an advance, its application in morbid obesity at present is limited. In this article, we review the technique and results of SILS in bariatric surgery. Methods: The PubMed database was searched and totally 11 series reporting SILS in bariatric surgery were identified and analyzed. The case reports were excluded. Since 2008, 114 morbidly obese patients receiving SILS bariatric surgeries were reported. Results: The procedures performed included SILS gastric banding, sleeve gastrectomy and gastric bypass. No mortality was reported in the literatures. Sixteen patients (14.05% needed an additional incision for a liver retractor, a trocar or for conversion. Only one complication of wound infection was reported in these series. All the surgeons reported that the patients were highly satisfied with the scar. Conclusion: Because of abundant visceral and subcutaneous fat and multiple comorbidities in morbid obesity, it is more challenging for surgeons to perform the procedures with SILS. It is clear that extensive development of new instruments and technical aspects of these procedures as well as randomized studies to compare them with traditional laparoscopy are essential before these procedures can be utilized in day-to-day clinical practice.

  15. Treatment for incarcerated indirect hernia with "Cross-Internal Ring" inguinal oblique incision in children.

    Science.gov (United States)

    Yan, Xue-Qiang; Yang, Jun; Zheng, Nan-Nan; Kuang, Hou-Fang; Duan, Xu-Fei; Bian, Hong-Qiang

    2017-01-01

    This study aims to evaluate the utility of the "Cross-Internal Ring" inguinal oblique incision for the surgical treatment of incarcerated indirect hernia (IIH) complicated with severe abdominal distension. Patients of IIH complicated with severe abdominal distension were reviewed retrospectively. All patients received operation through the "Cross-Internal Ring" inguinal oblique incision. There were totally 13 patients were included, male to female ratio was 9-4. The time for patients to resume oral feeding varying from 2 to 5 days after operation, no complications include delayed intestinal perforation, intra-abdominal abscess, and incision infection happened. Average postoperative hospital stay was 5.2 days. All cases were followed up for 6-18 months. No recurrence or iatrogenic cryptorchidism happened. "Cross-Internal Ring" inguinal oblique incision is a simple, safe, and reliable surgical method to treat pediatric IIH complicated with severe abdominal distension.

  16. Cleft palate repair with the use of osmotic expanders: a preliminary report.

    Science.gov (United States)

    Kobus, Kazimierz F

    2007-01-01

    A new method of cleft palate repair by expansion of tissue by means of osmotic expanders implanted in the first stage of treatment is described. Self-expanding expanders manufactured by OSMED (Ilmenau, Germany) were implanted under the mucoperiosteal layer of the hard palate, on purpose to generate more tissue and provide facility for palate repair performed 24-48h later. Nineteen children aged from 2 to 3 years were operated from January 2004 to 15 April 2005. In clefts10mm, cleft palate repair was more difficult and the outcomes were less favourable. Despite more generous dissection of the neurovascular bundles and other adjunctive measures such as mucosal V-Y plasty [Bardach J, Salyer K. Surgical techniques in cleft lip and palate. Chicago, London: Year Book Medical Publishers, Inc.; 1987.] and suturing of the mucosal grafts at the border of the hard and soft palate, seven 2-4mm fistulae were noted, however. Concluding, in spite of some shortcomings and unacceptable rate of fistula in wide clefts, the above-presented method seems to be an attractive concept. Despite some technical problems related mostly to still tested optimal filling phase, tissue expansion makes palate repair easier, probably without relaxing incisions and bone denudation. Consequently, some adverse effects on facial growth may be reduced. So far, there is no evidence for it, however, and since this is a preliminary report, there is a need for longer observations and larger material.

  17. Near-infrared spectroscopy (NIRS) as a new tool for neuroeconomic research

    Science.gov (United States)

    Kopton, Isabella M.; Kenning, Peter

    2014-01-01

    Over the last decade, the application of neuroscience to economic research has gained in importance and the number of neuroeconomic studies has grown extensively. The most common method for these investigations is fMRI. However, fMRI has limitations (particularly concerning situational factors) that should be countered with other methods. This review elaborates on the use of functional Near-Infrared Spectroscopy (fNIRS) as a new and promising tool for investigating economic decision making both in field experiments and outside the laboratory. We describe results of studies investigating the reliability of prototype NIRS studies, as well as detailing experiments using conventional and stationary fNIRS devices to analyze this potential. This review article shows that further research using mobile fNIRS for studies on economic decision making outside the laboratory could be a fruitful avenue helping to develop the potential of a new method for field experiments outside the laboratory. PMID:25147517

  18. Transverse Skin Crease versus Vertical Midline Incision versus Laparoscopy for Right Hemicolectomy: A Systematic Review—Current Status of Right Hemicolectomy

    Directory of Open Access Journals (Sweden)

    Alberto Santoro

    2014-01-01

    Full Text Available Purpose. The right hemicolectomy may be conducted through laparoscopic or laparotomic surgery, transverse or midline incisions. The transverse laparotomy offers some advantages compared to the midline laparotomy and laparoscopy. A literature review was performed to evaluate the possible advantages of the transverse incision versus midline incision or laparoscopic right hemicolectomy. Methods. A systematic research was performed in Medline, Embase, Cochrane Central Register of Controlled Trials, CINAHL, BioMed Central, and the Science Citation Index. Results. Laparotomic right hemicolectomy with transverse incision is preferable to laparotomic hemicolectomy with midline incision. A transverse incision offers a lessened postoperative pain following physical activity, a lessened need to administer analgesic therapy during the post-operative time, better aesthetic results, and a better post-operative pulmonary function. Open surgery with transverse or midline incision ensured a shorter operative time, lower costs and a greater length of the incision compared to the laparoscopic. However, there are no differences in the oncological outcomes. Conclusions. It was not possible to identify significant differences between the open right hemicolectomy with transverse incision versus the open right hemicolectomy with midline incision or laparoscopic hemicolectomy.

  19. Induction and repair of DNA base damage studied in X-irradiated CHO cells using the M. luteus extract

    International Nuclear Information System (INIS)

    Foehe, C.; Dikomey, E.

    1994-01-01

    DNA base damage was measured in Chinese hamster ovary cells X-irradiated under aerobic conditions using an extract of the bacterium Micrococcus luteus. The glycosylases and endonucleases present in this extract recognize damaged bases and convert them into strand breaks (termed endonuclease-sensitive sites, enss). Strand breaks were detected by the alkaline unwinding technique. The induction of enss was measured for X-ray doses ranging up to 45 Gy. The relative frequency of all enss related to all radiation induced strand breaks was 1.7 ± 0.4. Repair of enss was studied for a radiation dose of 45 Gy. The number of enss was found to decrease exponentially with time after irradiation with a half-time of τ enss = 37 ± 8 min. The repair kinetics that were also measured for all X-ray-induced DNA strand breaks were found to consist of three phases: fast, intermediate and slow. The intermediate phase was fitted under the assumption that this phase results from the information and repair of secondary single-strand breaks generated by enzymatic incision at the sites of base damage repair. (author)

  20. Robotic repair of vesicovaginal fistulae with the transperitoneal-transvaginal approach: A case series

    Directory of Open Access Journals (Sweden)

    Luciano A. Nunez Bragayrac

    2014-12-01

    Full Text Available Objective To describe a novel technique of repairing the VVF using the transperitoneal-transvaginal approach. Materials and Methods From June 2011 to October 2013, four patients with symptoms of urine leakage in the vagina underwent robotic repair of VVF with the transperitoneal-transvaginal approach. Cystoscopy revealed the fistula opening on the bladder. A ureteral stent was placed through the fistulous tract. After trocar placement, the omental flap was prepared and mobilized robotically. The vagina was identified and incised. The fistulous tract was excised. Cystorrhaphy was performed in two layers in an interrupted fashion. The vaginal opening was closed with running stitches. The omentum was interposed and anchored between the bladder and vagina. Finally, the ureteral catheters were removed in case they have been placed, and an 18 Fr urethral catheter was removed on the 14th postoperative day. Results The mean age was 46 years (range: 41 to 52 years. The mean fistula diameter was 1.5 cm (range 0.3 to 2 cm. The mean operative time was 117.5 min (range: 100 to 150 min. The estimated blood loss was 100 mL (range: 50 to 150 mL. The mean hospital stay was 1.75 days (range: 1 to 3 days. The mean Foley catheter duration was 15.75 days (range: 10 to 25 days. There was no evidence of recurrence in any of the cases. Conclusions The robot-assisted laparoscopic transperitoneal transvaginal approach for VVF is a feasible procedure when the fistula tract is identified by first intentionally opening the vagina, thereby minimizing the bladder incision and with low morbidity.

  1. Design, construction, and testing of an automated NIR in-line analysis system for potatoes. Part I: Off-line NIR feasibility study for the characterization of potato composition

    NARCIS (Netherlands)

    Brunt, K.; Drost, W.C.

    2010-01-01

    An off-line near-infrared reflectance (NIR) feasibility study was conducted to explore the critical steps in the NIR determination of the major potato constituents (dry matter, starch, and protein) in relatively large (10 kg) potato samples. The results were important for the design of an automated

  2. Minimal Nasolabial Incision Technique for Nasolabial Fold Modification in Patients With Facial Paralysis.

    Science.gov (United States)

    Faris, Callum; Heiser, Alyssa; Jowett, Nate; Hadlock, Tessa

    2018-03-01

    Creation of symmetrical nasolabial folds (NLFs) is important in the management of the paralyzed face. Established techniques use a linear incision in the NLF, and technical refinements now allow the linear incision to be omitted. This retrospective case series was conducted in a tertiary care setting from February 2, 2017, to June 7, 2017. Participants were all patients (N = 21) with peripheral facial paralysis who underwent NLF modification that used the minimal nasolabial incision technique at the Massachusetts Eye and Ear Infirmary Facial Nerve Center from February 1, 2015, through August 31, 2016. Patient-reported outcome measures using the validated, quality-of-life Facial Clinimetric Evaluation (FaCE) Scale; clinician-reported facial function outcomes using a validated electronic clinician-graded facial paralysis assessment (eFACE); layperson assessment of the overall aesthetic outcome of the NLF; and expert-clinician scar assessment of the NLF. Of the 21 patients who underwent NLF modification that used the minimal nasolabial incision technique, 9 patients (43%) were female and 12 (57%) were male. The mean age was 41 (range, 9-90) years; 17 patients (81%) were adults (≥18 years) and 4 (19%) were children (<18 years). Overall, significant improvements were observed after NLF modification in all outcome measures as graded by both clinicians and patients. The mean (SD) scores for total eFACE were 60.7 (14.9) before the operation and 77.2 (8.9) after the operation (mean difference, 16.5 [95% CI, 8.5-24.2]; P < .001). The mean (SD) static eFACE scores were 61.4 (20.6) before the operation and 82.7 (12.4) after the operation (mean difference, 21.3 [95% CI, 10.7-31.9]; P < .001). The mean (SD) FaCE quality-of-life scores were 51.3 (20.1) before the operation and 70.3 (12.6) after the operation (mean difference, 19.0 [95% CI, 6.5-31.6]; P  =  .001). The layperson self-assessment of the overall aesthetic outcome of the NLF modification was

  3. Beer fermentation: monitoring of process parameters by FT-NIR and multivariate data analysis.

    Science.gov (United States)

    Grassi, Silvia; Amigo, José Manuel; Lyndgaard, Christian Bøge; Foschino, Roberto; Casiraghi, Ernestina

    2014-07-15

    This work investigates the capability of Fourier-Transform near infrared (FT-NIR) spectroscopy to monitor and assess process parameters in beer fermentation at different operative conditions. For this purpose, the fermentation of wort with two different yeast strains and at different temperatures was monitored for nine days by FT-NIR. To correlate the collected spectra with °Brix, pH and biomass, different multivariate data methodologies were applied. Principal component analysis (PCA), partial least squares (PLS) and locally weighted regression (LWR) were used to assess the relationship between FT-NIR spectra and the abovementioned process parameters that define the beer fermentation. The accuracy and robustness of the obtained results clearly show the suitability of FT-NIR spectroscopy, combined with multivariate data analysis, to be used as a quality control tool in the beer fermentation process. FT-NIR spectroscopy, when combined with LWR, demonstrates to be a perfectly suitable quantitative method to be implemented in the production of beer. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Hemodynamic Response to Interictal Epileptiform Discharges Addressed by Personalized EEG-fNIRS Recordings

    Science.gov (United States)

    Pellegrino, Giovanni; Machado, Alexis; von Ellenrieder, Nicolas; Watanabe, Satsuki; Hall, Jeffery A.; Lina, Jean-Marc; Kobayashi, Eliane; Grova, Christophe

    2016-01-01

    Objective: We aimed at studying the hemodynamic response (HR) to Interictal Epileptic Discharges (IEDs) using patient-specific and prolonged simultaneous ElectroEncephaloGraphy (EEG) and functional Near InfraRed Spectroscopy (fNIRS) recordings. Methods: The epileptic generator was localized using Magnetoencephalography source imaging. fNIRS montage was tailored for each patient, using an algorithm to optimize the sensitivity to the epileptic generator. Optodes were glued using collodion to achieve prolonged acquisition with high quality signal. fNIRS data analysis was handled with no a priori constraint on HR time course, averaging fNIRS signals to similar IEDs. Cluster-permutation analysis was performed on 3D reconstructed fNIRS data to identify significant spatio-temporal HR clusters. Standard (GLM with fixed HRF) and cluster-permutation EEG-fMRI analyses were performed for comparison purposes. Results: fNIRS detected HR to IEDs for 8/9 patients. It mainly consisted oxy-hemoglobin increases (seven patients), followed by oxy-hemoglobin decreases (six patients). HR was lateralized in six patients and lasted from 8.5 to 30 s. Standard EEG-fMRI analysis detected an HR in 4/9 patients (4/9 without enough IEDs, 1/9 unreliable result). The cluster-permutation EEG-fMRI analysis restricted to the region investigated by fNIRS showed additional strong and non-canonical BOLD responses starting earlier than the IEDs and lasting up to 30 s. Conclusions: (i) EEG-fNIRS is suitable to detect the HR to IEDs and can outperform EEG-fMRI because of prolonged recordings and greater chance to detect IEDs; (ii) cluster-permutation analysis unveils additional HR features underestimated when imposing a canonical HR function (iii) the HR is often bilateral and lasts up to 30 s. PMID:27047325

  5. Hemodynamic response to Interictal Epileptiform Discharges addressed by personalized EEG-fNIRS recordings

    Directory of Open Access Journals (Sweden)

    Giovanni ePellegrino

    2016-03-01

    Full Text Available Objective: We aimed at studying the hemodynamic response (HR to Interictal Epileptic Discharges (IEDs using patient-specific and prolonged simultaneous ElectroEncephaloGraphy (EEG and functional Near InfraRed Spectroscopy (fNIRS recordings. Methods: The epileptic generator was localized using Magnetoencephalography source imaging. fNIRS montage was tailored for each patient, using an algorithm to optimize the sensitivity to the epileptic generator. Optodes were glued using collodion to achieve prolonged acquisition with high quality signal. fNIRS data analysis was handled with no a priori constraint on HR time course, averaging fNIRS signals to similar IEDs. Cluster-permutation analysis was performed on 3D reconstructed fNIRS data to identify significant spatio-temporal HR clusters. Standard (GLM with fixed HRF and cluster-permutation EEG-fMRI analyses were performed for comparison purposes. Results: fNIRS detected HR to IEDs for 8/9 patients. It mainly consisted oxy-hemoglobin increases (7 patients, followed by oxy-hemoglobin decreases (6 patients. HR was lateralized in 6 patients and lasted from 8.5 to 30s. Standard EEG-fMRI analysis detected an HR in 4/9 patients (4/9 without enough IEDs, 1/9 unreliable result. The cluster-permutation EEG-fMRI analysis restricted to the region investigated by fNIRS showed additional strong and non-canonical BOLD responses starting earlier than the IEDs and lasting up to 30s. Conclusions: i EEG-fNIRS is suitable to detect the HR to IEDs and can outperform EEG-fMRI because of prolonged recordings and greater chance to detect IEDs; ii cluster-permutation analysis unveils additional HR features underestimated when imposing a canonical HR function iii the HR is often bilateral and lasts up to 30s.

  6. Antibiotic prophylaxis for episiotomy repair following vaginal birth.

    Science.gov (United States)

    Bonet, Mercedes; Ota, Erika; Chibueze, Chioma E; Oladapo, Olufemi T

    2017-11-02

    Bacterial infections occurring during labour, childbirth, and the puerperium may be associated with considerable maternal and perinatal morbidity and mortality. Antibiotic prophylaxis might reduce wound infection incidence after an episiotomy, particularly in situations associated with a higher risk of postpartum perineal infection, such as midline episiotomy, extension of the incision, or in settings where the baseline risk of infection after vaginal birth is high. However, available evidence is unclear concerning the role of prophylactic antibiotics in preventing infections after an episiotomy. To assess whether routine antibiotic prophylaxis before or immediately after incision or repair of episiotomy for women with an uncomplicated vaginal birth, compared with either placebo or no antibiotic prophylaxis, prevents maternal infectious morbidities and improves outcomes. We searched the Cochrane Pregnancy and Childbirth's Trials Register, LILACS, ClinicalTrials.gov, and the WHO International Clinical Trials Registry Platform (ICTRP) on 24 July 2017, and screened reference lists of retrieved studies. We considered randomised controlled trials, quasi-randomised trials, and cluster-randomised trials that compared the use of routine antibiotic prophylaxis for incision or repair of an episiotomy for women with otherwise normal vaginal births, compared with either placebo or no antibiotic prophylaxis. Two review authors independently assessed trials for inclusion and risk of bias, extracted data, and checked them for accuracy. We only found one quasi-randomised trial that met the inclusion criteria and was included in the analysis, therefore, we did not perform a meta-analysis. We included one quasi-RCT (with data from 73 women) in the review. The trial, which was conducted in a public hospital in Brazil, compared oral chloramphenicol 500 mg four times daily for 72 hours after episiotomy repair (N = 34) and no treatment (N = 39). We assessed most of the domains at high

  7. Tissue oxygenation and haemodynamics measurement with spatially resolved NIRS

    Science.gov (United States)

    Zhang, Y.; Scopesi, F.; Serra, G.; Sun, J. W.; Rolfe, P.

    2010-08-01

    We describe the use of Near Infrared Spectroscopy (NIRS) for the non-invasive investigation of changes in haemodynamics and oxygenation of human peripheral tissues. The goal was to measure spatial variations of tissue NIRS oxygenation variables, namely deoxy-haemoglobin (HHb), oxy-haemoglobin (HbO2), total haemoglobin (HbT), and thereby to evaluate the responses of the peripheral circulation to imposed physiological challenges. We present a skinfat- muscle heterogeneous tissue model with varying fat thickness up to 15mm and a Monte Carlo simulation of photon transport within this model. The mean partial path length and the mean photon visit depth in the muscle layer were derived for different source-detector spacing. We constructed NIRS instrumentation comprising of light-emitting diodes (LED) as light sources at four wavelengths, 735nm, 760nm, 810nm and 850nm and sensitive photodiodes (PD) as the detectors. Source-detector spacing was varied to perform measurements at different depths within forearm tissue. Changes in chromophore concentration in response to venous and arterial occlusion were calculated using the modified Lambert-Beer Law. Studies in fat and thin volunteers indicated greater sensitivity in the thinner subjects for the tissue oxygenation measurement in the muscle layer. These results were consistent with those found using Monte Carlo simulation. Overall, the results of this investigation demonstrate the usefulness of the NIRS instrument for deriving spatial information from biological tissues.

  8. Strength of bone tunnel versus suture anchor and push-lock construct in Broström repair.

    Science.gov (United States)

    Giza, Eric; Nathe, Ryan; Nathe, Tyler; Anderson, Matthew; Campanelli, Valentina

    2012-06-01

    Operative treatment of mechanical ankle instability is indicated for patients who have had multiple sprains and have continued episodes of instability despite bracing and rehabilitation. Anatomic reconstruction has been shown to have improved outcomes and return to sport as compared with nonanatomic reconstruction. The use of 2 suture anchors and a push-lock anchor is equal to 2 bone tunnels in strength to failure for anatomic Broström repair. Controlled laboratory study. In 7 matched pairs of human cadaver ankles, the calcaneofibular ligament (CFL) and anterior talofibular ligament (ATFL) were incised from their origin on the fibula. A No. 2 Fiberwire suture was placed into the CFL and a separate suture into the ATFL in a running Krackow fashion with a total of 4 locking loops. In 1 ankle of the matched pair, the ligaments were repaired to their anatomic insertion with bone tunnels. In the other, 2 suture anchors were used to reattach the ligaments to their anatomic origins, and a push-lock was used proximally to reinforce these suture anchors. The ligaments were cyclically loaded 20 times and then tested to failure. Torque to failure, degrees to failure, and stiffness were measured. The authors performed a matched pair analysis. An a priori power analysis of 0.8 demonstrated 6 pairs were needed to show a difference of 30% with a 15% standard error at a significance level of .05. There was no difference in the degrees to failure, torque to failure, and stiffness. A post hoc power analysis of torque to failure showed a power of .89 with 7 samples. Power for initial stiffness was .97 with 7 samples. Eleven of 14 specimens failed at either the suture anchor or the bone tunnel. There is no statistical difference in strength or stiffness for a suture anchor and push-lock construct as compared with a bone tunnel construct for an anatomic repair of the lateral ligaments of the ankle. The use of suture anchors in lateral ligament stabilization allows for a smaller

  9. Cutting electrocautery versus scalpel for surgical incisions: a systematic review and meta-analysis.

    Science.gov (United States)

    Ismail, Ammar; Abushouk, Abdelrahman Ibrahim; Elmaraezy, Ahmed; Menshawy, Amr; Menshawy, Esraa; Ismail, Mahmoud; Samir, Esraa; Khaled, Anas; Zakarya, Hagar; El-Tonoby, Abdelrahman; Ghanem, Esraa

    2017-12-01

    Although cutting electrocautery can be superior to the scalpel in reducing blood loss and incisional time, several reports associated electrocautery with higher rates of wound infection, impaired healing, and worse cosmesis. We performed this systematic review and meta-analysis to compare cutting electrocautery versus scalpel for surgical incisions. We conducted a computerized literature search of five electronic databases and included all published original studies comparing cutting electrocautery and scalpel surgical incisions. Relevant data were extracted from eligible studies and pooled as odds ratios (ORs) or standardized mean difference (SMD) values in a meta-analysis model, using RevMan and Comprehensive Meta-analysis software. Forty-one studies (36 randomized trials, four observational, and one quasirandom study) were included in the pooled analysis (6422 participants). Compared with the scalpel incision, cutting electrocautery resulted in significantly less blood loss (SMD = -1.16, 95% CI [-1.60 to -0.72]), shorter incisional (SMD = -0.63, 95% CI [-0.96 to -0.29]) and operative times (SMD = -0.59, 95% CI [-1.12 to -0.05]), and lower pain scores (SMD = -0.91, 95% CI [-1.27 to -0.55]) with no significant differences in terms of wound infection rates (OR = 0.92, 95% CI [0.74-1.15]) or overall subjective scar score (SMD = -0.49, 95% CI [-1.72 to 0.75]). Surgical incision using electrocautery can be quicker with less blood loss and postoperative pain scores than the scalpel incision. No statistically significant difference was found between both techniques in terms of postoperative wound complications, hospital stay duration, and wound cosmetic characteristics. Therefore, we recommend routine use of cutting electrocautery for surgical incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. DNA polymerase. beta. reaction with ultraviolet-irradiated DNA incised by correndonuclease

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, R; Zarebska, Z [Instytut Onkologii, Warsaw (Poland); Zmudzka, B [Polska Akademia Nauk, Warsaw. Inst. Biochemii i Biofizyki

    1980-09-19

    Covalently closed circular Col E1 DNA was ultraviolet-irradiated with a dose of 60 J/m/sup 2/, thus introducing about 3.2 pyrimidine dimers per DNA molecule. Treatment of irradiated Col E1 DNA with Micrococcus luteus correndonuclease resulted, in the vicinity of pyrimidine dimers, in an average of 3.3 incisions per DNA molecule, and converted DNA to the open circular form. Incised Col E1 DNA stimulated no reaction with calf thymus DNA polymerase ..cap alpha.. but was recognized as a template by DNA polymerase ..beta... The latter enzyme incorporated about 1.6 molecules of dTMP (corresponding to 6 molecules of dNMP) per one correndonuclease incision. The length of the DNA polymerase ..beta.. product was comparable to the anticipated length of the DNA region within which the hydrogen bonds were disrupted owing to dimer formation. The enzyme required Mg/sup 2 +/ and four dNTPs for reaction and was resistant to N-ethylmaleimide or p-mercuribenzoate.

  11. Acrylamide inverse miniemulsion polymerization: in situ, real-time monitoring using nir spectroscopy

    Directory of Open Access Journals (Sweden)

    M. M. E. Colmán

    2014-12-01

    Full Text Available In this work, the ability of on-line NIR spectroscopy for the prediction of the evolution of monomer concentration, conversion and average particle diameter in acrylamide inverse miniemulsion polymerization was evaluated. The spectral ranges were chosen as those representing the decrease in concentration of monomer. An increase in the baseline shift indicated that the NIR spectra were affected by particle size. Multivariate partial least squares calibration models were developed to relate NIR spectra collected by the immersion probe with off-line conversion and polymer particle size data. The results showed good agreement between off-line data and values predicted by the NIR calibration models and these latter were also able to detect different types of operational disturbances. These results indicate that it is possible to monitor variables of interest during acrylamide inverse miniemulsion polymerizations.

  12. Is there Place for Perfectionism in the NIR Spectral Data Reduction?

    Science.gov (United States)

    Chilingarian, Igor

    2017-09-01

    "Despite the crucial importance of the near-infrared spectral domain for understanding the star formation and galaxy evolution, NIR observations and data reduction represent a significant challenge. The known complexity of NIR detectors is aggravated by the airglow emission in the upper atmosphere and the water absorption in the troposphere so that up until now, the astronomical community is divided on the issue whether ground based NIR spectroscopy has a future or should it move completely to space (JWST, Euclid, WFIRST). I will share my experience of pipeline development for low- and intermediate-resolution spectrographs operated at Magellan and MMT. The MMIRS data reduction pipeline became the first example of the sky subtraction quality approaching the limit set by the Poisson photon noise and demonstrated the feasibility of low-resolution (R=1200-3000) NIR spectroscopy from the ground even for very faint (J=24.5) continuum sources. On the other hand, the FIRE Bright Source Pipeline developed specifically for high signal-to-noise intermediate resolution stellar spectra proves that systematics in the flux calibration and telluric absorption correction can be pushed down to the (sub-)percent level. My conclusion is that even though substantial effort and time investment is needed to design and develop NIR spectroscopic pipelines for ground based instruments, it will pay off, if done properly, and open new windows of opportunity in the ELT era."

  13. Femtosecond laser effect on the self-sealing properties of the corneal incision of various lengths and profile (experimental trial

    Directory of Open Access Journals (Sweden)

    Yulduz Shavkatovna Nizametdinova

    2015-06-01

    Full Text Available An experimental investigation was carried out to study self-sealing properties of corneal incisions of different profile and length carried out with femtosecond laser Victus (Technolas Perfect Vision/Bausch&Lomb. Using femtosecond laser for this purpose allows creating corneal incisions of high precision and predictability. Reproducibility and standardization of the incision profile and length are an advantage of this technology. Obtained results showed that single-profile incisions are less stable and safe when compared to multi-profile ones. It was noted that incision length increase promotes its self-sealing properties.

  14. The role of cell hydration in realization of biological effects of non-ionizing radiation (NIR).

    Science.gov (United States)

    Ayrapetyan, Sinerik

    2015-09-01

    The weak knowledge on the nature of cellular and molecular mechanisms of biological effects of NIR such as static magnetic field, infrasound frequency of mechanical vibration, extremely low frequency of electromagnetic fields and microwave serves as a main barrier for adequate dosimetry from the point of Public Health. The difficulty lies in the fact that the biological effects of NIR depend not only on their thermodynamic characteristics but also on their frequency and intensity "windows", chemical and physical composition of the surrounding medium, as well as on the initial metabolic state of the organism. Therefore, only biomarker can be used for adequate estimation of biological effect of NIR on organisms. Because of the absence of such biomarker(s), organizations having the mission to monitor hazardous effects of NIR traditionally base their instruction on thermodynamic characteristics of NIR. Based on the high sensitivity to NIR of both aqua medium structure and cell hydration, it is suggested that cell bathing medium is one of the primary targets and cell hydration is a biomarker for NIR effects on cells and organisms. The purpose of this article is to present a short review of literature and our own experimental data on the effects of NIR on plants' seeds germination, microbe growth and development, snail neurons and heart muscle, rat's brain and heart tissues.

  15. Radioecological studies in early period of NIRS

    International Nuclear Information System (INIS)

    Ichikawa, Ryushi

    2004-01-01

    Japanese tuna-fishing boat Fukuryumaru No.5 was exposed to heavy radioactive fallout due to the nuclear test explosion carried out by U.S.A. at Bikini Atoll of Marshal Islands in the central part of Pacific Ocean on March 1, 1954. Following this accident, radioactivity was detected in various environmental samples including rain, marine fishes and agricultural crops. Science Council of Japan organized the new research group of many scientists in the field of fisheries, agricultural, medical and biological studies and radiation protection studies. Government of Japan established National Institute of Radiological Sciences (NIRS) in 1957. In this Institute various radioecological studies have been carried out. In this paper, some of these radioecological studies carried out in early period of NIRS are described. (author)

  16. Urinary diversion in hypospadias repair: suprapubic cystostomy versus transurethral catheterization

    International Nuclear Information System (INIS)

    Qamar, S.A.; Pansota, M.S.; Rasool, M.; Ali, S.; Shahzad, M.

    2013-01-01

    Objective: To compare the results of suprapubic with transurethral urinary diversion in hypospadias repair. Data Source: Patients admitted to the Department of Urology and Renal Transplantation with distal or middle hypospadias. Design of Study: Randomized Controlled Trials. Setting: Department of Urology and Renal Transplantation, Quaid-I-Azam Medical College /Bahawal Victoria Hospital, Bahawalpur. Period: From June 2010 to December 2011. Materials and Methods: A total of sixty patients, 1 to 10 years of age with distal or middle hypospadias were included in the study. Patients with history of previous hypospadias repair were excluded. Patients were divided in two groups by using random numbers table, 30 patients in each group. Group I had suprapubic and Group II had transurethral urinary diversion. Tubularized Incised Plate urethroplasty and Mathieu's repair were commonly used techniques. Stent was kept for 7-14 days. Patient discharged from hospital at 72 hours post-operatively with urethral catheter or suprapubic cystostomy intact. Patients were followed for subsequent outcome. Follow up was initially fortnightly and then at 1 month intervals. Minimum follow up period was 3 months and maximum 18 months for these particular patients. Results: Only two patients of Group I had complications as compared to seven patients of Group II. Moreover, patient discomfort and voiding problems was more with group II than group I. Nursing care was easy in group I patients. Complication rate was significantly 10 where in group I as compared to group II. Conclusion: The overall complication rate and patient discomfort were significantly lower with suprapubic urinary diversion in hypospadias repair, which also had a better cosmetic outcome. (author)

  17. A new technique, combined plication-incision (CPI, for correction of penile curvature

    Directory of Open Access Journals (Sweden)

    Hamed Abdalla Hamed

    Full Text Available ABSTRACT Introduction Penile curvature (PC can be surgically corrected by either corporoplasty or plication techniques. These techniques can be complicated by post-operative: penile shortening, recurrent PC, painful/palpable suture knots and erectile dysfunction. Objective To avoid the complications of corporoplasty and plication techniques using a new technique: combined plication-incision (CPI. Materials and Methods Two groups (1&2 were operated upon: group 1 using CPI and group 2 using the 16-dot technique. In CPI, dots were first marked as in 16 dot technique. In each group of 4 dots the superficial layer of tunica albuginea was transversely incised (3-6mm at the first and last dots. Ethibond 2/0, passed through the interior edge of the first incision plicating the intermediate 2 dots and passed out of the interior edge of the last incision, was tightened and ligated. Vicryle 4/0, passed through the exterior edges of the incisions, was tightened and ligated to cover the ethibond knot. Results Twelve (57.1 % participants in group 2 complained of a bothering palpable knot compared to none in group 1 with statistically significant difference (P=0.005. Postoperative shortening (5mm of erect penis, encountered in 9 participants, was doubled in group 2 but with insignificant difference (P>0.05. Post-operative recurrence of PC, was encountered in only 1 (4.8% participant in group 2, compared to none in group 1, with insignificant difference (P>0.05. Post-operative erectile rigidity was normally maintained in all participants. Conclusion The new technique was superior to the 16-dot technique for correction of PC.

  18. Arthroscopic Removal and Tendon Repair for Refractory Rotator Cuff Calcific Tendinitis of the Shoulder.

    Science.gov (United States)

    Hashiguchi, Hiroshi; Iwashita, Satoshi; Okubo, Atsushi; Takai, Shinro

    2017-01-01

    The purpose of this study was to evaluate clinical and radiological outcomes of arthroscopic treatment for refractory rotator cuff calcific tendinitis of the shoulder. Subjects were 37 patients (35 women and 2 men; mean age, 47.8 years; age range 34-61 years) who had undergone arthroscopic treatment for calcific tendinitis of the shoulder. Despite sufficient nonsurgical treatments, all patients had residual calcific deposit with persistent or recurrent pain. Before surgery, all patients underwent 3-directional radiographs of the shoulder and three-dimensional computed tomography to determine the location and size of calcific deposit. Arthroscopic surgery was performed with the patient under general anesthesia in the lateral decubitus position. A 2-cm single longitudinal incision was made with a radiofrequency hook blade on the tendon surface above calcific deposit. Calcific deposit was removed as much as possible with a curette and a motorized shaver. The incised tendon was repaired with a side-to-side suture with strong sutures. The Japanese Orthopaedic Association shoulder score was used to evaluate clinical outcomes. The extent of calcific deposit removal was evaluated with radiographs obtained before surgery, 1 week after the surgery and at the final follow-up examination. The mean follow-up duration was 30.4 (range, 13-72) months. The mean shoulder score significantly improved from 69.7 (range, 58-80) points before surgery to 97.8 (range, 89-100) points at the final follow-up examination. Postoperative radiographs in all patients, showed that the calcific deposit was resolved or reduced and those from 1 week after surgery to the final examination showed no evidence of recurrence or enlargement of calcific deposit. The calcific deposit had completely resolved in 34 patients but remained in 3 patients. When treating calcific tendinitis of the shoulder, it is important to accurately determine the size and location of calcific deposit by radiographs and 3

  19. Full-Thickness Retinochoroidal Incision in the Management of Central Retinal Vein Occlusion

    Directory of Open Access Journals (Sweden)

    San-Ni Chen

    2015-01-01

    Full Text Available Purpose. To evaluate the clinical outcomes in patients with central retinal vein occlusion (CRVO treated with full-thickness retinochoroidal incisions and to compare whether there is difference in treatment response in ischemic and nonischemic CRVO. Methods. Retrospective study of patients of CRVO receiving full-thickness retinochoroidal incisions in Changhua Christian Hospital. Fluorescein angiography (FA, slit-lamp biomicroscopy, indirect funduscopy, best corrected visual acuity, and central macular thickness (CMT measured by optical coherence tomography were performed pre- and postoperatively. Patients were divided into an ischemic and nonischemic group according to the findings of FA. Patients were followed up for at least 1 year. Results. Twenty-eight eyes (14 ischemic and 14 nonischemic CRVO were included. Functional retinochoroidal venous anastomosis (RCVA was achieved in 48 of the 65 retinochoroidal incisions (73.8%. Central macular thickness (CMT and retinal hemorrhage decreased significantly after the surgery. Significant visual gain was observed postoperatively in the nonischemic group, but not in the ischemic group. Postoperative complications included vitreous hemorrhage (17.8%, neovascular glaucoma (7.1%, and preretinal fibrovasular membrane (10.7%, all of which were in the ischemic group. Conclusions. RCVA formation induced by retinochoroidal incisions could improve venous flow, and decrease CMT and retinal hemorrhage. However, only eyes with nonischemic CRVO showed visual improvement.

  20. The Evolution of the Appendectomy: From Open to Laparoscopic to Single Incision

    Directory of Open Access Journals (Sweden)

    Noah J. Switzer

    2012-01-01

    Full Text Available Beginning with its initial description by Fitz in the 19th century, acute appendicitis has been a significant long-standing medical challenge; today it remains the most common gastrointestinal emergency in adults. Already in 1894, McBurney advocated for the surgical removal of the inflamed appendix and is credited with the initial description of an Open Appendectomy (OA. With the introduction of minimally invasive surgery, this classic approach evolved into a procedure with multiple, smaller incisions; a technique termed Laparoscopic Appendectomy (LA. There is much literature describing the advantages of this newer approach. To name a few, patients have significantly less wound infections, reduced pain, and a reduction in ileus compared with the OA. In the past few years, Single Incision Laparoscopic Appendectomy (SILA has gained popularity as the next major evolutionary advancement in the removal of the appendix. Described as a pioneer in the era of “scarless surgery,” it involves only one transumbilical incision. Patients are postulated to have reduced post-operative complications such as infection, hernias, and hematomas, as well as a quicker recovery time and less post-operative pain scores, in comparison to its predecessors. In this review, we explore the advancement of the appendectomy from open to laparoscopic to single incision.

  1. N-Butyrate alters chromatin accessibility to DNA repair enzymes

    International Nuclear Information System (INIS)

    Smith, P.J.

    1986-01-01

    Current evidence suggests that the complex nature of mammalian chromatin can result in the concealment of DNA damage from repair enzymes and their co-factors. Recently it has been proposed that the acetylation of histone proteins in chromatin may provide a surveillance system whereby damaged regions of DNA become exposed due to changes in chromatin accessibility. This hypothesis has been tested by: (i) using n-butyrate to induce hyperacetylation in human adenocarcinoma (HT29) cells; (ii) monitoring the enzymatic accessibility of chromatin in permeabilised cells; (iii) measuring u.v. repair-associated nicking of DNA in intact cells and (iv) determining the effects of n-butyrate on cellular sensitivity to DNA damaging agents. The results indicate that the accessibility of chromatin to Micrococcus luteus u.v. endonuclease is enhanced by greater than 2-fold in n-butyrate-treated cells and that there is a corresponding increase in u.v. repair incision rates in intact cells exposed to the drug. Non-toxic levels of n-butyrate induce a block to G1 phase transit and there is a significant growth delay on removal of the drug. Resistance of HT29 cells to u.v.-radiation and adriamycin is enhanced in n-butyrate-treated cells whereas X-ray sensitivity is increased. Although changes in the responses of cells to DNA damaging agents must be considered in relation to the effects of n-butyrate on growth rate and cell-cycle distribution, the results are not inconsistent with the proposal that increased enzymatic-accessibility/repair is biologically favourable for the resistance of cells to u.v.-radiation damage. Overall the results support the suggested operation of a histone acetylation-based chromatin surveillance system in human cells

  2. Techniques for creating inconspicuous face-lift scars: avoiding visible incisions and loss of temporal hair.

    Science.gov (United States)

    Kridel, Russell W H; Liu, Edmund S

    2003-01-01

    Patients seeking rhytidectomy desire an improved neckline, jawline, and midface, but rarely at the price of signs that betray a face-lift, namely, visible incisions. We describe our face-lift incisional planning and the rationale behind specific surgical maneuvers for preventing unwanted sequelae. The telltale signs of poorly placed incisions include temporal hair loss, conspicuous scars, an unnatural appearance to the tragus, and a posterior hairline distorsion. Special considerations are given to the male patient and to the salvage of readily visible incision lines from previous surgery.

  3. Channel Incision Driven by Suburbanization: Impacts to Riparian Groundwater Flow and Overbank Flow Frequency

    Science.gov (United States)

    Bowles, C. J.; Lawrence, R. L.; Noll, C.; Hancock, G. S.

    2005-12-01

    Channel incision is a widely observed response to increased flow in urbanized watersheds, but the effects of channel lowering on riparian water tables is not well documented. In a rapidly incising suburban stream in the Virginia Coastal Plain, we hypothesize that stream incision has lowered floodplain water tables and decreased the overbank flow frequency. The monitored stream is a tributary to the James River draining 1.3 km2 of which 15% is impervious cover. Incision has occurred largely through upstream migration of a one meter high knickpoint at a rate of ~1.5 m/yr, primarily during high flow events. We installed 63 wells in six stream-perpendicular transects as well as a cluster of wells around the knickpoint to assess water table elevations beneath the floodplain adjacent to the incising stream. Two transects are located 30 and 50 m upstream of the knickpoint in the unincised floodplain, and the remainder are 5, 30, 70, and 100 m downstream in the incised floodplain. In one transect above and two below, pressure transducers attached to dataloggers provide a high-resolution record of water table changes. Erosion pins were installed and channel cross-sections surveyed to determine streambed stability. Significant differences are observed in bank morphology and groundwater flow above vs. below the knickpoint. Above the knickpoint, the banks are stable, ~3 m wide, and ~0.3 m deep, and widen and deepen slightly toward the knickpoint. The water table is relatively flat and is 0.2-0.4 m below the floodplain surface, and groundwater contours suggest flow is parallel to the stream direction. The water table responds immediately to precipitation events, and rises to the floodplain surface in significant rainfall events. Immediately downstream of the knickpoint, channel width increases by about a meter, and stream depth increases to ~1.5 meters. The water table immediately below the knickpoint possesses a steep gradient, and is up to one meter below the floodplain

  4. Repair process and a repaired component

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, III, Herbert Chidsey; Simpson, Stanley F.

    2018-02-20

    Matrix composite component repair processes are disclosed. The matrix composite repair process includes applying a repair material to a matrix composite component, securing the repair material to the matrix composite component with an external securing mechanism and curing the repair material to bond the repair material to the matrix composite component during the securing by the external securing mechanism. The matrix composite component is selected from the group consisting of a ceramic matrix composite, a polymer matrix composite, and a metal matrix composite. In another embodiment, the repair process includes applying a partially-cured repair material to a matrix composite component, and curing the repair material to bond the repair material to the matrix composite component, an external securing mechanism securing the repair material throughout a curing period, In another embodiment, the external securing mechanism is consumed or decomposed during the repair process.

  5. Near-infrared (NIR) optogenetics using up-conversion system

    Science.gov (United States)

    Hososhima, Shoko; Yuasa, Hideya; Ishizuka, Toru; Yawo, Hiromu

    2015-03-01

    Non-invasive remote control technologies designed to manipulate neural functions for a comprehensive and quantitative understanding of the neuronal network in the brain as well as for the therapy of neurological disorders have long been awaited. Recently, it has become possible to optically manipulate the neuronal activity using biological photo-reactive molecules such as channelrhodopsin-2 (ChR2). However, ChR2 and its relatives are mostly reactive to visible light which does not effectively penetrate through biological tissues. In contrast, near-infrared (NIR) light penetrates deep into the tissues because biological systems are almost transparent to light within this so-called `imaging window'. Here we used lanthanide nanoparticles (LNPs), which are composed of rare-earth elements, as luminous bodies to activate channelrhodopsins (ChRs) since they absorb low-energy NIR light to emit high-energy visible light (up-conversion). Neuron-glioma-hybrid ND-7/23 cells were cultured with LNP(NaYF4:Sc/Yb/Er) particles (peak emission, 543 nm) and transfected to express C1V1 (peak absorbance, 539 nm), a chimera of ChR1 and VChR1. The photocurrents were generated in response to NIR laser light (976 nm) to a level comparable to that evoked by a filtered Hg lamp (530-550 nm). NIR light pulses also evoked action potentials in the cultured neurons that expressed C1V1. It is suggested that the green luminescent light emitted from LNPs effectively activated C1V1 to generate the photocurrent. With the optimization of LNPs, acceptor photo-reactive biomolecules and optics, this system could be applied to non-invasively actuate neurons deep in the brain.

  6. Suitability of faecal near-infrared reflectance spectroscopy (NIRS) predictions for estimating gross calorific value

    Energy Technology Data Exchange (ETDEWEB)

    De la Roza-Delgado, B.; Modroño, S.; Vicente, F.; Martínez-Fernández, A.; Soldado, A.

    2015-07-01

    A total of 220 faecal pig and poultry samples, collected from different experimental trials were employed with the aim to demonstrate the suitability of Near Infrared Reflectance Spectroscopy (NIRS) technology for estimation of gross calorific value on faeces as output products in energy balances studies. NIR spectra from dried and grounded faeces samples were analyzed using a Foss NIRSystem 6500 instrument, scanning over the wavelength range 400-2500 nm. Validation studies for quantitative analytical models were carried out to estimate the relevance of method performance associated to reference values to obtain an appropriate, accuracy and precision. The results for prediction of gross calorific value (GCV) of NIRS calibrations obtained for individual species showed high correlation coefficients comparing chemical analysis and NIRS predictions, ranged from 0.92 to 0.97 for poultry and pig. For external validation, the ratio between the standard error of cross validation (SECV) and the standard error of prediction (SEP) varied between 0.73 and 0.86 for poultry and pig respectively, indicating a sufficiently precision of calibrations. In addition a global model to estimate GCV in both species was developed and externally validated. It showed correlation coefficients of 0.99 for calibration, 0.98 for cross-validation and 0.97 for external validation. Finally, relative uncertainty was calculated for NIRS developed prediction models with the final value when applying individual NIRS species model of 1.3% and 1.5% for NIRS global prediction. This study suggests that NIRS is a suitable and accurate method for the determination of GCV in faeces, decreasing cost, timeless and for convenient handling of unpleasant samples.. (Author)

  7. Diseno y construccion de un espectrometro NIR; Design and construction of a NIR spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Barcala Riveira, J M; Fernandez Marron, J L; Alberdi Primicia, J; Molero Menendez, F; Navarrete Marin, J J; Oller Gonzalez, J C

    2003-07-01

    This document describes the design and construction of a NIR spectrometer based on an acoustic-optic tunable filter. The spectrometer will be used for automatic identification of plastics in domestic waste. The system works between 1200 and 1800 nm. Instrument is controlled by a personal computer. Computer receives and analyses data. A software package has been developed to do these tasks. (Author) 27 refs.

  8. Community Structure of Denitrifiers, Bacteria, and Archaea along Redox Gradients in Pacific Northwest Marine Sediments by Terminal Restriction Fragment Length Polymorphism Analysis of Amplified Nitrite Reductase (nirS) and 16S rRNA Genes

    Science.gov (United States)

    Braker, Gesche; Ayala-del-Río, Héctor L.; Devol, Allan H.; Fesefeldt, Andreas; Tiedje, James M.

    2001-01-01

    Steep vertical gradients of oxidants (O2 and NO3−) in Puget Sound and Washington continental margin sediments indicate that aerobic respiration and denitrification occur within the top few millimeters to centimeters. To systematically explore the underlying communities of denitrifiers, Bacteria, and Archaea along redox gradients at distant geographic locations, nitrite reductase (nirS) genes and bacterial and archaeal 16S rRNA genes (rDNAs) were PCR amplified and analyzed by terminal restriction fragment length polymorphism (T-RFLP) analysis. The suitablility of T-RFLP analysis for investigating communities of nirS-containing denitrifiers was established by the correspondence of dominant terminal restriction fragments (T-RFs) of nirS to computer-simulated T-RFs of nirS clones. These clones belonged to clusters II, III, and IV from the same cores and were analyzed in a previous study (G. Braker, J. Zhou, L. Wu, A. H. Devol, and J. M. Tiedje, Appl. Environ. Microbiol. 66:2096–2104, 2000). T-RFLP analysis of nirS and bacterial rDNA revealed a high level of functional and phylogenetic diversity, whereas the level of diversity of Archaea was lower. A comparison of T-RFLPs based on the presence or absence of T-RFs and correspondence analysis based on the frequencies and heights of T-RFs allowed us to group sediment samples according to the sampling location and thus clearly distinguish Puget Sound and the Washington margin populations. However, changes in community structure within sediment core sections during the transition from aerobic to anaerobic conditions were minor. Thus, within the top layers of marine sediments, redox gradients seem to result from the differential metabolic activities of populations of similar communities, probably through mixing by marine invertebrates rather than from the development of distinct communities. PMID:11282647

  9. Laparoscopic repair for vesicouterine fistulae

    Directory of Open Access Journals (Sweden)

    Rafael A. Maioli

    2015-10-01

    Full Text Available ABSTRACT Objective: The purpose of this video is to present the laparoscopic repair of a VUF in a 42-year-old woman, with gross hematuria, in the immediate postoperative phase following a cesarean delivery. The obstetric team implemented conservative management, including Foley catheter insertion, for 2 weeks. She subsequently developed intermittent hematuria and cystitis. The urology team was consulted 15 days after cesarean delivery. Cystoscopy indicated an ulcerated lesion in the bladder dome of approximately 1.0cm in size. Hysterosalpingography and a pelvic computed tomography scan indicated a fistula. Materials and Methods: Laparoscopic repair was performed 30 days after the cesarean delivery. The patient was placed in the lithotomy position while also in an extreme Trendelenburg position. Pneumoperitoneum was established using a Veress needle in the midline infra-umbilical region, and a primary 11-mm port was inserted. Another 11-mm port was inserted exactly between the left superior iliac spine and the umbilicus. Two other 5-mm ports were established under laparoscopic guidance in the iliac fossa on both sides. The omental adhesions in the pelvis were carefully released and the peritoneum between the bladder and uterus was incised via cautery. Limited cystotomy was performed, and the specific sites of the fistula and the ureteral meatus were identified; thereafter, the posterior bladder wall was adequately mobilized away from the uterus. The uterine rent was then closed using single 3/0Vicryl sutures and two-layer watertight closure of the urinary bladder was achieved by using 3/0Vicryl sutures. An omental flap was mobilized and inserted between the uterus and the urinary bladder, and was fixed using two 3/0Vicryl sutures, followed by tube drain insertion. Results: The operative time was 140 min, whereas the blood loss was 100ml. The patient was discharged 3 days after surgery, and the catheter was removed 12 days after surgery

  10. Performance of fast-absorbable suture and histo-glue in closing incisions in Brown trout

    DEFF Research Database (Denmark)

    Jepsen, Niels; Larsen, Martin Hage; Aarestrup, Kim

    2017-01-01

    , growth, tag expulsion rate and incision healing was compared among three groups of dummy transmitter-tagged wild brown trout Salmo trutta where incisions were closed with two types of suture material (absorbable vs. fast absorbable) and Histo-glue. The tagged fish were kept in semi-natural ponds for 20...

  11. Distraction decreases prefrontal oxygenation: A NIRS study.

    Science.gov (United States)

    Ozawa, Sachiyo; Hiraki, Kazuo

    2017-04-01

    When near-infrared spectroscopy (NIRS) is used to measure emotion-related cerebral blood flow (CBF) changes in the prefrontal cortex regions, the functional distinction of CBF changes is often difficult because NIRS is unable to measure neural activity in deeper brain regions that play major roles in emotional processing. The CBF changes could represent cognitive control of emotion and emotional responses to emotional materials. Supposing that emotion-related CBF changes in the prefrontal cortex regions during distraction are emotional responses, we examined whether oxygenated hemoglobin (oxyHb) decreases. Attention-demanding tasks cause blood flow decreases, and we thus compared the effects of visually paced tapping with different tempos, on distraction. The results showed that the oxyHb level induced by emotional stimulation decreased with fast-tempo tapping significantly more than slow-tempo tapping in ventral medial prefrontal cortex regions. Moreover, a Global-Local task following tapping showed significantly greater local-minus-global response time (RT) difference scores in the fast- and mid-tempo condition compared with those in the slow-tempo, suggesting an increased attentional focus, and decreased negative emotion. The overall findings indicate that oxyHb changes in a relatively long distraction task, as measured by NIRS, are associated with emotional responses, and oxyHb can be decreased by successfully performing attention-demanding distraction tasks. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Automatic moisture content determination on biomass with NIR and radio frequency spectroscopy; Automatisk fukthaltsmaetning paa biobraenslen med NIR samt radiofrekvent spektroskopi

    Energy Technology Data Exchange (ETDEWEB)

    Dahlquist, Erik; Nystroem, Jenny; Thorin, Eva; Paz, Ana de la [Maelardalen Univ. (Sweden). Dept. of Public Technology; Axrup, Lars [Stora Enso AB (Sweden)

    2005-08-01

    The goal with the project has been to evaluate two methods for determination of moisture content in biomass fuels and to determine if these methods can be used in practice in connection with delivery control of biomass at power plants. Tests have been performed with different biomass qualities and with two different measurement methods within a large moisture span, 0.6-72%. The two methods have been NIR (Near Infrared spectroscopy), and RF (Radio Frequency spectroscopy). The NIR-method is a surface analysis method, where hydro-carbons like wood have a different absorption pattern than water. The RF-method is a bulk method and utilizes that wood and water have different dielectric constants. Radio waves thus are affected differently by transportation through wet and dry biomass. In this project we have studied how representative sampling can be achieved from a large volume of delivered biomass fuel. We also have performed calibration with mixtures of the different fuels. Sampling has been performed by extracting biomass in a four meter long screw from the large volume as it is poured into a storage vessel. A conveyor belt is then transporting the material to the measurement systems. Two different NIR-instruments, DA (Diod Array) -NIR respective FT (Fourier Transform)- NIR, were placed above the conveyor belt. The material was collected from the belt into the measuring vessel for the RF, a 200 liter 'oil barrel'. The radio waves were sent from the transceiver into the sample from above without direct contact between the biomass and the transceiver antenna. Six different fuels were studied separately. Calibration was performed where the moisture content was varied by mixing relatively dry fuel with humidified biomass in different proportions a day before the measurements. Samples were taken from each mixture in connection with the measurements, from the conveyor belt. The samples were made in such a way that they represented the whole volume as good as

  13. Stratigraphic architecture of back-filled incised-valley systems: Pennsylvanian-Permian lower Cutler beds, Utah, USA

    Science.gov (United States)

    Wakefield, Oliver J. W.; Mountney, Nigel P.

    2013-12-01

    The Pennsylvanian to Permian lower Cutler beds collectively form the lowermost stratigraphic unit of the Cutler Group in the Paradox Basin, southeast Utah. The lower Cutler beds represent a tripartite succession comprising lithofacies assemblages of aeolian, fluvial and shallow-marine origin, in near equal proportion. The succession results from a series of transgressive-regressive cycles, driven by repeated episodes of climatic variation and linked changes in relative sea-level. Relative sea-level changes created a number of incised-valleys, each forming through fluvial incision during lowered base-level. Aeolian dominance during periods of relative sea-level lowstand aids incised-valley identification as the erosive bounding surface juxtaposes incised-valley infill against stacked aeolian faces. Relative sea-level rises resulted in back-flooding of the incised-valleys and their infill via shallow-marine and estuarine processes. Back-flooded valleys generated marine embayments within which additional local accommodation was exploited. Back-filling is characterised by a distinctive suite of lithofacies arranged into a lowermost, basal fill of fluvial channel and floodplain architectural elements, passing upwards into barform elements with indicators of tidal influence, including inclined heterolithic strata and reactivation surfaces. The incised-valley fills are capped by laterally extensive and continuous marine limestone elements that record the drowning of the valleys and, ultimately, flooding and accumulation across surrounding interfluves (transgressive surface). Limestone elements are characterised by an open-marine fauna and represent the preserved expression of maximum transgression.

  14. The boomerang incision for periareolar breast malignancies.

    Science.gov (United States)

    Tan, Mona P

    2007-11-01

    Breast-conservation surgery has been shown to be equivalent to mastectomy in terms of long-term survival for the treatment of breast cancer. Various techniques have been described on how to achieve clear margins and good cosmetic outcomes and therefore expand the indications for breast conservation. A novel incision is detailed to augment the options already available.

  15. Incisional hernia after upper abdominal surgery: A randomised controlled trial of midline versus transverse incision

    NARCIS (Netherlands)

    J.A. Halm (Jens); H. Lip (Harm); P.I.M. Schmitz (Paul); J. Jeekel (Hans)

    2009-01-01

    textabstractObjectives: To determine whether a transverse incision is an alternative to a midline incision in terms of incisional hernia incidence, surgical site infection, postoperative pain, hospital stay and cosmetics in cholecystectomy. Summary background data: Incisional hernias after midline

  16. Phenomenon of mucous retention in the incisive canal.

    Science.gov (United States)

    Keith, D A

    1979-11-01

    Mucous glands are rarely found in the anterior palate but may be observed in the incisive canal. A case history is presented of a lesion that resembled a nasopalatine cyst both clinically and radiographically but which was in fact an intra-bony extravasation phenomenon.

  17. Comparison of first-intention healing of carbon dioxide laser, 4.0-MHz radiosurgery, and scalpel incisions in ball pythons (Python regius).

    Science.gov (United States)

    Hodshon, Rebecca T; Sura, Patricia A; Schumacher, Juergen P; Odoi, Agricola; Steeil, James C; Newkirk, Kim M

    2013-03-01

    To evaluate first-intention healing of CO(2) laser, 4.0-MHz radiowave radiosurgery (RWRS), and scalpel incisions in ball pythons (Python regius). 6 healthy adult ball pythons. A skin biopsy sample was collected, and 2-cm skin incisions (4/modality) were made in each snake under anesthesia and closed with surgical staples on day 0. Incision sites were grossly evaluated and scored daily. One skin biopsy sample per incision type per snake was obtained on days 2, 7, 14, and 30. Necrotic and fibroplastic tissue was measured in histologic sections; samples were assessed and scored for total inflammation, histologic response (based on the measurement of necrotic and fibroplastic tissues and total inflammation score), and other variables. Frequency distributions of gross and histologic variables associated with wound healing were calculated. Gross wound scores were significantly greater (indicating greater separation of wound edges) for laser incisions than for RWRS and scalpel incisions at all evaluated time points. Necrosis was significantly greater in laser and RWRS incisions than in scalpel incision sites on days 2 and 14 and days 2 and 7, respectively; fibroplasia was significantly greater in laser than in scalpel incision sites on day 30. Histologic response scores were significantly lower for scalpel than for other incision modalities on days 2, 14, and 30. In snakes, skin incisions made with a scalpel generally had less necrotic tissue than did CO(2) laser and RWRS incisions. Comparison of the 3 modalities on the basis of histologic response scores indicated that use of a scalpel was preferable, followed by RWRS and then laser.

  18. Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Langberg, H; Olesen, J

    2001-01-01

    , brain and connective tissue, and more recently it has been used in the clinical setting to assess circulatory and metabolic abnormalities. Quantitative measures of blood flow are also possible using NIRS and a light-absorbing tracer, which can be applied to evaluate circulatory responses to exercise......Near infrared spectroscopy (NIRS) is becoming a widely used research instrument to measure tissue oxygen (O2) status non-invasively. Continuous-wave spectrometers are the most commonly used devices, which provide semi-quantitative changes in oxygenated and deoxygenated hemoglobin in small blood...... vessels (arterioles, capillaries and venules). Refinement of NIRS hardware and the algorithms used to deconvolute the light absorption signal have improved the resolution and validity of cytochrome oxidase measurements. NIRS has been applied to measure oxygenation in a variety of tissues including muscle...

  19. Smaller incision size leads to higher predictability in microcoaxial cataract surgery.

    Science.gov (United States)

    Klamann, Matthias K J; Gonnermann, Johannes; Maier, Anna-Karina B; Torun, Necip; Bertelmann, Eckart

    2013-01-01

    The aim of the study was to compare the clinical outcomes of a 1.8 mm, 2.2 mm, and 2.75 mm microcoaxial cataract surgery system. METHODS. In this retrospective study, 129 eyes of 129 patients were included. Patients underwent phacoemulsification using a Stellaris system or an Infiniti system. The incision size was 1.8 mm, 2.2 mm, or 2.75 mm, respectively. Subjects were examined before surgery and 4 weeks after. The surgically induced astigmatism (SIA) was examined. The SIA in the 1.8 mm group was statistically lower compared to the 2.2 mm group (p=0.046) and the 2.75 mm group (p=0.017). There was no significant difference between the 2.2 mm group and the 2.75 mm group. With the use of appropriate support systems, 1.8 mm incisions appear to result in less SIA than 2.2 mm and 2.75 mm incisions. Advantages may arise from this, especially in the implantation of aspheric, toric, or multifocal lenses.

  20. Fuji apple storage time rapid determination method using Vis/NIR spectroscopy

    Science.gov (United States)

    Liu, Fuqi; Tang, Xuxiang

    2015-01-01

    Fuji apple storage time rapid determination method using visible/near-infrared (Vis/NIR) spectroscopy was studied in this paper. Vis/NIR diffuse reflection spectroscopy responses to samples were measured for 6 days. Spectroscopy data were processed by stochastic resonance (SR). Principal component analysis (PCA) was utilized to analyze original spectroscopy data and SNR eigen value. Results demonstrated that PCA could not totally discriminate Fuji apples using original spectroscopy data. Signal-to-noise ratio (SNR) spectrum clearly classified all apple samples. PCA using SNR spectrum successfully discriminated apple samples. Therefore, Vis/NIR spectroscopy was effective for Fuji apple storage time rapid discrimination. The proposed method is also promising in condition safety control and management for food and environmental laboratories. PMID:25874818

  1. Modified tubularized incised plate urethroplasty reduces the risk of fistula and meatal stenosis for proximal hypospadias: a report of 63 cases.

    Science.gov (United States)

    Arshadi, Hamid; Sabetkish, Shabnam; Kajbafzadeh, Abdol-Mohammad

    2017-12-01

    To report the feasibility of modified tubularized incised plate (TIP) urethroplasty technique for proximal hypospadias in 63 cases. From January 2004 to March 2010, 63 patients underwent one-stage TIP urethroplasty (modified Snodgrass technique repair) using 2-3 of three covering layers (corpus spongiosum, dartos, and tunica vaginalis). The primary meatus was proximal penile, penoscrotal, scrotal, and perineal in 38, 13, 10, and 2 patients, respectively. All patients had chordee that was corrected with dorsal plication. Glanuloplasty was performed in all cases. Complications and cosmetic results were documented after 6-72 months of follow-up. A total of 63 boys with proximal hypospadias underwent Snodgrass hypospadias repair at a mean age of 8.5 months (range 6-54). Mean operative time was 210 ± 35 min. Patients were followed up with 6-month intervals for up to 6 years postoperatively. After 6 years of follow-up, nine urethrocutaneous fistulae, four bleeding, four meatal stenoses, and one urethral stricture were reported. Cosmetic result was satisfactory according to parent's opinion and another surgeon. No residual chordee was observed in any cases (without artificial correction). In conclusion, this preliminary report can be estimated as an alternative technique with acceptable complication and cosmetic results for proximal hypospadias correction.

  2. Yeast DNA-repair gene RAD14 encodes a zinc metalloprotein with affinity for ultraviolet-damaged DNA

    International Nuclear Information System (INIS)

    Guzder, S.N.; Sung, P.; Prakash, S.; Prakash, L.

    1993-01-01

    Xeroderma pigmentosum (XP) patients suffer from a high incidence of skin cancers due to a defect in excision repair of UV light-damaged DNA. Of the seven XP complementation groups, A--G, group A represents a severe and frequent form of the disease. The Saccharomyces cerevisiae RAD14 gene is a homolog of the XP-A correcting (XPAC) gene. Like XP-A cells, rad14-null mutants are defective in the incision step of excision repair of UV-damaged DNA. The authors have purified RAD14 protein to homogeneity from extract of a yeast strain genetically tailored to overexpress RAD14. As determined by atomic emission spectroscopy, RAD14 contains one zinc atom. They also show in vitro that RAD14 binds zinc but does not bind other divalent metal ions. In DNA mobility-shift assays, RAD14 binds specifically to UV-damaged DNA. Removal of cyclobutane pyrimidine dimers from damaged DNA by enzymatic photoreactivation has no effect on binding, strongly suggesting that RAD14 recognizes pyrimidine(6-4)pyrimidone photoproduct sites. These findings indicate that RAD14 functions in damage recognition during excision repair. 37 refs., 4 figs

  3. PAT: From Western solid dosage forms to Chinese materia medica preparations using NIR-CI.

    Science.gov (United States)

    Zhou, Luwei; Xu, Manfei; Wu, Zhisheng; Shi, Xinyuan; Qiao, Yanjiang

    2016-01-01

    Near-infrared chemical imaging (NIR-CI) is an emerging technology that combines traditional near-infrared spectroscopy with chemical imaging. Therefore, NIR-CI can extract spectral information from pharmaceutical products and simultaneously visualize the spatial distribution of chemical components. The rapid and non-destructive features of NIR-CI make it an attractive process analytical technology (PAT) for identifying and monitoring critical control parameters during the pharmaceutical manufacturing process. This review mainly focuses on the pharmaceutical applications of NIR-CI in each unit operation during the manufacturing processes, from the Western solid dosage forms to the Chinese materia medica preparations. Finally, future applications of chemical imaging in the pharmaceutical industry are discussed. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Association of Concurrent fNIRS and EEG Signatures in Response to Auditory and Visual Stimuli.

    Science.gov (United States)

    Chen, Ling-Chia; Sandmann, Pascale; Thorne, Jeremy D; Herrmann, Christoph S; Debener, Stefan

    2015-09-01

    Functional near-infrared spectroscopy (fNIRS) has been proven reliable for investigation of low-level visual processing in both infants and adults. Similar investigation of fundamental auditory processes with fNIRS, however, remains only partially complete. Here we employed a systematic three-level validation approach to investigate whether fNIRS could capture fundamental aspects of bottom-up acoustic processing. We performed a simultaneous fNIRS-EEG experiment with visual and auditory stimulation in 24 participants, which allowed the relationship between changes in neural activity and hemoglobin concentrations to be studied. In the first level, the fNIRS results showed a clear distinction between visual and auditory sensory modalities. Specifically, the results demonstrated area specificity, that is, maximal fNIRS responses in visual and auditory areas for the visual and auditory stimuli respectively, and stimulus selectivity, whereby the visual and auditory areas responded mainly toward their respective stimuli. In the second level, a stimulus-dependent modulation of the fNIRS signal was observed in the visual area, as well as a loudness modulation in the auditory area. Finally in the last level, we observed significant correlations between simultaneously-recorded visual evoked potentials and deoxygenated hemoglobin (DeoxyHb) concentration, and between late auditory evoked potentials and oxygenated hemoglobin (OxyHb) concentration. In sum, these results suggest good sensitivity of fNIRS to low-level sensory processing in both the visual and the auditory domain, and provide further evidence of the neurovascular coupling between hemoglobin concentration changes and non-invasive brain electrical activity.

  5. A STUDY ON EFFICACY OF MANUAL SMALL INCISION CATARACT SURGERY BY TEMPORAL APPROACH

    Directory of Open Access Journals (Sweden)

    Vinodhini Kannan

    2018-01-01

    Full Text Available BACKGROUND Manual Small Incision Cataract Surgery (MSICS is a well-known technique of cataract surgery owing to its advantage of a selfsealing suture less incision with least surgically induced astigmatism at a low cost. It is a safe, simple, consistent, stable and cost-effective technique with various modifications that involve site, size, type of incision and method of nucleus delivery. One such modification is Temporal Incision MSICS, where the cataract surgery is done by a temporal approach, which is equally good compared to the superior incision. This study was done retrospectively to analyse the visual outcome of patients operated by Manual SICS - Temporal Approach, using the WHO criteria and to establish its efficacy as a good surgical technique. MATERIALS AND METHODS Records of patients operated for senile cataract by a single surgeon by Temporal MSICS using a temporal sclerocorneal incision of 6-6.5 mm, during a 1-year period, were analysed retrospectively. Post-operative followup records of POD-1 and subsequent follow-ups at 1 st week and 6 th week were recorded for visual outcome. RESULTS Out of the 83 cases analysed retrospectively, majority of them were found to be between 61-70 years with a female Preponderance. Most of the cases were found to have senile immature cataract (55 patients, with Grade III nuclear sclerosis (52 cases. The pre-operative visual acuity was poor <6/60 in 72 cases (86.7% and borderline in 11 cases (14.5%. 55 cases (66.3% had a 6.5 mm scleral incision and the remaining 28 cases (33.7% had a 6 mm incision. Average duration of surgery noted was 8.35 minutes. Striate Keratopathy was the most common 1 st POD complication followed by corneal oedema. Striate keratopathy was the most common complication at the 1 st week followup followed by pigment dispersion. Majority of cases (76 cases were found to have been complication free at the end of 6 weeks. At the end of 6 weeks post-operatively as per records, 80 cases

  6. [Determination of wine original regions using information fusion of NIR and MIR spectroscopy].

    Science.gov (United States)

    Xiang, Ling-Li; Li, Meng-Hua; Li, Jing-Mingz; Li, Jun-Hui; Zhang, Lu-Da; Zhao, Long-Lian

    2014-10-01

    Geographical origins of wine grapes are significant factors affecting wine quality and wine prices. Tasters' evaluation is a good method but has some limitations. It is important to discriminate different wine original regions quickly and accurately. The present paper proposed a method to determine wine original regions based on Bayesian information fusion that fused near-infrared (NIR) transmission spectra information and mid-infrared (MIR) ATR spectra information of wines. This method improved the determination results by expanding the sources of analysis information. NIR spectra and MIR spectra of 153 wine samples from four different regions of grape growing were collected by near-infrared and mid-infrared Fourier transform spe trometer separately. These four different regions are Huailai, Yantai, Gansu and Changli, which areall typical geographical originals for Chinese wines. NIR and MIR discriminant models for wine regions were established using partial least squares discriminant analysis (PLS-DA) based on NIR spectra and MIR spectra separately. In PLS-DA, the regions of wine samples are presented in group of binary code. There are four wine regions in this paper, thereby using four nodes standing for categorical variables. The output nodes values for each sample in NIR and MIR models were normalized first. These values stand for the probabilities of each sample belonging to each category. They seemed as the input to the Bayesian discriminant formula as a priori probability value. The probabilities were substituteed into the Bayesian formula to get posterior probabilities, by which we can judge the new class characteristics of these samples. Considering the stability of PLS-DA models, all the wine samples were divided into calibration sets and validation sets randomly for ten times. The results of NIR and MIR discriminant models of four wine regions were as follows: the average accuracy rates of calibration sets were 78.21% (NIR) and 82.57% (MIR), and the

  7. Estimation of crosstalk in LED fNIRS by photon propagation Monte Carlo simulation

    Science.gov (United States)

    Iwano, Takayuki; Umeyama, Shinji

    2015-12-01

    fNIRS (functional near-Infrared spectroscopy) can measure brain activity non-invasively and has advantages such as low cost and portability. While the conventional fNIRS has used laser light, LED light fNIRS is recently becoming common in use. Using LED for fNIRS, equipment can be more inexpensive and more portable. LED light, however, has a wider illumination spectrum than laser light, which may change crosstalk between the calculated concentration change of oxygenated and deoxygenated hemoglobins. The crosstalk is caused by difference in light path length in the head tissues depending on wavelengths used. We conducted Monte Carlo simulations of photon propagation in the tissue layers of head (scalp, skull, CSF, gray matter, and white matter) to estimate the light path length in each layers. Based on the estimated path lengths, the crosstalk in fNIRS using LED light was calculated. Our results showed that LED light more increases the crosstalk than laser light does when certain combinations of wavelengths were adopted. Even in such cases, the crosstalk increased by using LED light can be effectively suppressed by replacing the value of extinction coefficients used in the hemoglobin calculation to their weighted average over illumination spectrum.

  8. WIRELESS DISTRIBUTED ACQUISITION SYSTEM FOR NEAR INFRARED SPECTROSCOPY – WDA-NIRS

    Directory of Open Access Journals (Sweden)

    J. SAFAIE

    2013-07-01

    Full Text Available The wireless distributed acquisition system for near infrared spectroscopy (WDA-NIRS is a portable, ultra-compact, continuous wave (CW NIRS system. Its main advantage is that it allows continuous synchronized multi-site hemodynamic monitoring. The WDA-NIRS system calculates online changes in hemoglobin concentration based on modified Beer–Lambert law and the tissue oxygenation index based on the spatial-resolved spectroscopy method. It consists of up to seven signal acquisition units, sufficiently small to be easily attached to any part of the body. These units are remotely synchronized by a PC base station for independent acquisition of NIRS signals. Each acquisition module can be freely adapted to individual requirements such as local skin properties and the microcirculation of interest, e.g., different muscles, brain, skin, etc. For this purpose, the light emitted by each LED can be individually, interactively or automatically adjusted to local needs. Furthermore, the user can freely create an emitter time-multiplexing protocol and choose the detector sensitivity most suitable to a particular situation. The potential diagnostic value of this advanced device is demonstrated by three typical applications.

  9. Prediction of pH and color in pork meat using VIS-NIR Near-infrared Spectroscopy (NIRS

    Directory of Open Access Journals (Sweden)

    Elton Jhones Granemann FURTADO

    2018-06-01

    Full Text Available Abstract The potential of near-infrared spectroscopy (NIRS to predict the physicochemical characteristics of the porcine longissimus dorsi (LD muscle was evaluated in comparison to the standard methods of pH and color for meat quality analysis compared to the pH results with Colorimeter and pH meter. Spectral information from each sample (n = 77 was obtained as the average of 32 successive scans acquired over a spectral range from 400 - 2498 nm with a 2 - nm gap for calibration and validation models. Partial least squares (PLS regression was used for each individual model. An R2 and a residual predictive deviation (RPD of 0.67/1.7, 0.86/2, and 0.76/1.9 were estimated for color parameters L*, a *, and b*, respectively. Final pH had an R2 of 0.67 and a RPD of 1.6. NIRS showed great potential to predict color parameter a * of porcine LD muscle. Further studies with larger samples should help improve model quality.

  10. Oral subcutaneous midline leiomyomatous hamartoma presenting as congenital incisive papilla overgrowth in a toddler

    Directory of Open Access Journals (Sweden)

    Ashish Loomba

    2017-01-01

    Full Text Available Congenital soft-tissue tumors of oral cavity are mostly hyperplastic and benign in nature. This article presents an unusual case of congenital subcutaneous hamartoma of incisive papilla in a 2-year-old female child causing feeding and breathing difficulty. Total excisional biopsy was done under local anesthesia. Histopathology of tissue in reticulin-stained slide showed the presence of immature muscle fibers whereas Masson's trichrome stain revealed collagen fibers and smooth muscles confirming the diagnosis of oral midline subcutaneous smooth muscle (leiomyomatous hamartoma of incisive papilla. It is important for dental professionals to be aware of this oral lesion present from birth mimicking overgrowth of incisive papilla, by its presentation, differential diagnosis, histopathology, and management.

  11. Effect of arsenite on the DNA repair of UV-irradiated Chinese hamster ovary cells

    International Nuclear Information System (INIS)

    Lee-Chen, S.F.; Yu, C.T.; Jan, K.Y.

    1992-01-01

    Arsenite, an ubiquitous human carcinogen, has been shown to enhance the cytotoxicity, mutagenicity and clastogenicity of UV light in mammalian cells. Arsenite may exert its co-genotoxic effects by inhibiting DNA repair. Results from alkaline sucrose gradient sedimentation show that arsenite did not accumulate UV-induced DNA strand breaks in Chinese hamster ovary (CHO) K1 cells as aphidicolin plus hydroxyurea (HU) did. These data indicate that arsenite did not inhibit the activity of DNA polymerase α in UV repair. Treatment with arsenite before UV irradiation slightly reduced the DNA strand breaks accumulated by cytosine β-D-arabinofuranoside (AraC) plus HU. This effect implies that arsenite only slightly inhibited the incision of UV-induced DNA adducts. The low molecular weight DNA accumulated by post-UV incubation with AraC plus HU shifted to high molecular weight upon the incubation of cells in drug-free medium, but this shifting was prohibited by the presence of arsenite. This suggests that arsenite inhibited the rejoining of DNA strand breaks. When a pulse-chase labelling procedure was applied on UV-irradiated cells, the chain elongation of nascent DNA was strongly inhibited by post-incubation with arsenite. These data show that arsenite inhibited post-replication repair in UV-irradiated cells. Therefore, the steps inhibited by arsenite in UV-induced cells. Therefore, the steps inhibited by arsenite in UV-induced DNA repair in CHO K1 cells are different from human fibroblasts. (author)

  12. Minilaparoscopic technique for inguinal hernia repair combining transabdominal pre-peritoneal and totally extraperitoneal approaches.

    Science.gov (United States)

    Carvalho, Gustavo L; Loureiro, Marcelo P; Bonin, Eduardo A; Claus, Christiano P; Silva, Frederico W; Cury, Antonio M; Fernandes, Flavio A M

    2012-01-01

    Endoscopic surgical repair of inguinal hernia is currently conducted using 2 techniques: the totally extraperitoneal (TEP) and the transabdominal (TAPP) hernia repair. The TEP procedure is technically advantageous, because of the use of no mesh fixation and the elimination of the peritoneal flap, leading to less postoperative pain and faster recovery. The drawback is that TEP is not performed as frequently, because of its complexity and longer learning curve. In this study, we propose a hybrid technique that could potentially become the gold standard of minimally invasive inguinal hernia surgery. This will be achieved by combining established advantages of TEP and TAPP associated with the precision and cosmetics of minilaparoscopy (MINI). Between January and July 2011, 22 patients were admitted for endoscopic inguinal hernia repair. The combined technique was initiated with TAPP inspection and direct visualization of a minilaparoscopic trocar dissection of the preperitoneum space. A10-mm trocar was then placed inside the previously dissected preperitoneal space, using the same umbilical TAPP skin incision. Minilaparoscopic retroperitoneal dissection was completed by TEP, and the surgical procedure was finalized with intraperitoneal review and correction of the preperitoneal work. The minilaparoscopic TEP-TAPP combined approach for inguinal hernia is feasible, safe, and allows a simple endoscopic repair. This is achieved by combining features and advantages of both TAPP and TEP techniques using precise and sophisticated MINI instruments. Minilaparoscopic preperitoneal dissection allows a faster and easier creation of the preperitoneal space for the TEP component of the procedure.

  13. Effect of arsenite on the DNA repair of UV-irradiated Chinese hamster ovary cells

    Energy Technology Data Exchange (ETDEWEB)

    Lee-Chen, S.F.; Yu, C.T.; Jan, K.Y. (Academia Sinica, Taipei, (Taiwan). Institute of Zoology)

    1992-01-01

    Arsenite, an ubiquitous human carcinogen, has been shown to enhance the cytotoxicity, mutagenicity and clastogenicity of UV light in mammalian cells. Arsenite may exert its co-genotoxic effects by inhibiting DNA repair. Results from alkaline sucrose gradient sedimentation show that arsenite did not accumulate UV-induced DNA strand breaks in Chinese hamster ovary (CHO) K1 cells as aphidicolin plus hydroxyurea (HU) did. These data indicate that arsenite did not inhibit the activity of DNA polymerase [alpha] in UV repair. Treatment with arsenite before UV irradiation slightly reduced the DNA strand breaks accumulated by cytosine [beta]-D-arabinofuranoside (AraC) plus HU. This effect implies that arsenite only slightly inhibited the incision of UV-induced DNA adducts. The low molecular weight DNA accumulated by post-UV incubation with AraC plus HU shifted to high molecular weight upon the incubation of cells in drug-free medium, but this shifting was prohibited by the presence of arsenite. This suggests that arsenite inhibited the rejoining of DNA strand breaks. When a pulse-chase labelling procedure was applied on UV-irradiated cells, the chain elongation of nascent DNA was strongly inhibited by post-incubation with arsenite. These data show that arsenite inhibited post-replication repair in UV-irradiated cells. Therefore, the steps inhibited by arsenite in UV-induced cells. Therefore, the steps inhibited by arsenite in UV-induced DNA repair in CHO K1 cells are different from human fibroblasts. (author).

  14. High transverse skin incisions may reduce wound complications in obese women having cesarean sections: a pilot study.

    Science.gov (United States)

    Walton, Robert B; Shnaekel, Kelsey L; Ounpraseuth, Songthip T; Napolitano, Peter G; Magann, Everett F

    2017-11-01

    Women having cesarean section have a high risk of wound complications. Our objective was to determine whether high transverse skin incisions are associated with a reduced risk of cesarean wound complications in women with BMI greater than 40. A retrospective cohort study was undertaken of parturients ages 18-45 with BMI greater than 40 having high transverse skin incisions from January 2010 to April 2015 at a tertiary maternity hospital. Temporally matched controls had low transverse skin incisions along with a BMI greater than 40. The primary outcome, wound complication, was defined as any seroma, hematoma, dehiscence, or infection requiring opening and evacuating/debriding the wound. Secondary outcomes included rates of endometritis, number of hospital days, NICU admission, Apgar scores, birth weight, and gestational age at delivery. Analysis of outcomes was performed using two-sample t-test or Wilcoxon rank-sum test for continuous variables and Fisher's exact test for categorical variables. Thirty-two women had high transverse incisions and were temporally matched with 96 controls (low transverse incisions). The mean BMI was 49 for both groups. There was a trend toward reduced wound complications in those having high transverse skin incisions, but this did not reach statistical significance (15.63% versus 27.08%, p = .2379). Those having high transverse skin incisions had lower five minute median Apgar scores (8.0 versus 9.0, p = .0021), but no difference in umbilical artery pH values. The high transverse group also had increased NICU admissions (28.13% versus 5.21%, p = .0011), and early gestational age at delivery (36.8 versus 38.0, p = .0272). High transverse skin incisions may reduce the risk of wound complications in parturients with obesity. A study with more power should be considered.

  15. Near-infrared (NIR) emitting conjugated polymers for biomedical applications (Presentation Recording)

    Science.gov (United States)

    Repenko, Tatjana; Kuehne, Alexander J. C.

    2015-10-01

    Fluorescent biomedical markers of today such as dye-infiltrated colloids, microgels and quantum dots suffer from fast bleaching, lack surface functionality (for targets or pharmaceutical agents) and potentially leach heavy metals in case of quantum dots (e.g. Cd). By contrast, conjugated polymer particles are non-cytotoxic, exhibit reduced bleaching, as the entire particle consists of fluorophore, they are hydrophobic and show high quantum yields. Consequently, conjugated polymer particles represent ideal materials for biological applications and imaging. However currently, conjugated polymer particles for biomedical imaging usually lack near-infrared (NIR) emission and are polydisperse. Fluorescent agents with emission in the NIR spectrum are interesting for biomedical applications due to their low photo-damage towards biological species and the ability of NIR radiation to penetrate deep into biological tissue.. I will present the development and synthesis of new conjugated polymers particles with fluorescence in the NIR spectral region for bio-imaging and clinical diagnosis. The particle synthesis proceeds in a one-step Pd or Ni-catalyzed dispersion polymerization of functional NIR emitters. The resulting monodisperse conjugated polymer particles are obtained as a dispersion in a non-hazardous solvent. Different sizes in the sub-micrometer range with a narrow size distribution can be produced. Furthermore biological recognition motifs can be easily attached to the conjugated polymers via thiol-yne click-chemistry providing specific tumor targeting without quenching of the fluorescence. References [1] Kuehne AJC, Gather MC, Sprakel J., Nature Commun. 2012, 3, 1088. [2] Repenko T, Fokong S, De Laporte L, Go D, Kiessling F, Lammers T, Kuehne AJC.,Chem Commun 2015, accepted.

  16. Relationship between muscle oxygenation by NIRS and blood lactate

    International Nuclear Information System (INIS)

    Xu Guodong; Mao Zongzhen; Ye Yanjie; Lv Kunru

    2011-01-01

    The aim of the study was to investigate the relationship of muscle oxygenation in term of oxy-hemoglobin concentration change (ΔHbO 2 ) by NIRS and blood lactate (BLA) in local skeletal muscle and evaluate the capability of NIRS in the research of exercise physiology Twenty-three athlete in the national fin-swimming team took the increasing load training on the power bicycle while their ΔHbO 2 and BLA were simultaneously recorded. The initial powers used in the training were set as 100 w for males and 40 w for females. During the experiment, the power kept constant for 3 min before each abrupt increment of 30 w until the limit of the athlete's capability. Statistical analysis and data visualization were performed. Following the increasing load training, ΔHbO 2 step-likely increased in the phase of aerobic metabolism but linearly decreased in the phase of anaerobic metabolism. The variation tendency of BLA was the same as ΔHbO 2 and the concurrency of crucial turning points between ΔHbO 2 and BLA was revealed. This relationship between ΔHbO 2 and BLA presented in the increasing load training suggested that ΔHbO 2 might be capable for taking the place of the invasively measured parameter BLA. Considering that ΔHbO 2 can be noninvasively measured by NIRS, ΔHbO 2 has the potential in the evaluation of athletes' physiological function and training effect on the athletes and accordingly NIRS can be well used in this field.

  17. S-shaped versus conventional straight skin incision: Impact on primary functional maturation, stenosis and thrombosis of autogenous radiocephalic arteriovenous fistula: Impact of incision on maturation, stenosis & failure of RCAVF. Study design: Prospective observational comparative.

    Science.gov (United States)

    Kordzadeh, Ali; Panayiotopolous, Yiannis

    2017-10-01

    The objective of this study is to test the null hypothesis that an S-shaped surgical incision versus conventional (straight) skin incision in the creation of autogenous radiocephalic arteriovenous fistulas (RCAVFs) have no impact on the primary end-point of primary functional maturation and secondary end points of stenosis and thrombosis. A prospective observational comparative consecutive study with intention-to-treat on individuals undergoing only radiocephalic arteriovenous fistula (RCAVFs) over a period of 12 months was conducted. Variables on patient's demographics, comorbidities, anesthesia type, mean arterial blood pressure, thrill, laterality, cephalic vein and radial artery diameter were collated. The test of probability was assessed through Chi-Square, Kaplan-Meier survival estimator and Log-Rank analysis. Total of n = 83 individuals with median age of 67 years (IQR, 20-89) and male predominance 83% during this period were subjected to RCAVF formation. Total of n = 45 patients in straight skin incision were compared to n = 38 individuals in S-shaped group. Despite equal prevalence of demographics, comorbidities, anesthesia type, mean arterial blood pressure (MAP), thrill, laterality, cephalic vein and radial artery diameter ( p  > 0.05) higher incidence of juxta-anastomotic stenosis was noted in the straight skin incision group ( p  = 0.029) in comparative and survival analysis (Log-Rank, p  = 0.036). The maturation of the entire cohort was 69% (S-shaped 76% vs. straight group 62%) (p > 0.05). The outcome of this study demonstrates that S-shaped surgical skin incision is associated with a lower incidence of stenosis in comparison to straight incision type in RCAVF formation.

  18. Rapid fluvial incision of a late Holocene lava flow: Insights from LiDAR, alluvial stratigraphy, and numerical modeling

    Science.gov (United States)

    Sweeney, Kristin; Roering, Joshua J.

    2016-01-01

    Volcanic eruptions fundamentally alter landscapes, paving over channels, decimating biota, and emplacing fresh, unweathered material. The fluvial incision of blocky lava flows is a geomorphic puzzle. First, high surface permeability and lack of sediment should preclude geomorphically effective surface runoff and dissection. Furthermore, past work has demonstrated the importance of extreme floods in driving incision via column toppling and plucking in columnar basalt, but it is unclear how incision occurs in systems where surface blocks are readily mobile. We examine rapid fluvial incision of the Collier lava flow, an andesitic Holocene lava flow in the High Cascades of Oregon. Since lava flow emplacement ∼1600 yr ago, White Branch Creek has incised bedrock gorges up to 8 m deep into the coherent core of the lava flow and deposited >0.2 km3 of sediment on the lava flow surface. Field observation points to a bimodal discharge regime in the channel, with evidence for both annual snowmelt runoff and outburst floods from Collier glacier, as well as historical evidence of vigorous glacial meltwater. To determine the range of discharge events capable of incision in White Branch Creek, we used a mechanistic model of fluvial abrasion. We show that the observed incision implies that moderate flows are capable of both initiating channel formation and sustaining incision. Our results have implications for the evolution of volcanic systems worldwide, where glaciation and/or mass wasting may accelerate fluvial processes by providing large amounts of sediment to otherwise porous, sediment-starved landscapes.

  19. Study of Vis/NIR spectroscopy measurement on acidity of yogurt

    Science.gov (United States)

    He, Yong; Feng, Shuijuan; Wu, Di; Li, Xiaoli

    2006-09-01

    A fast measurement of pH of yogurt using Vis/NIR-spectroscopy techniques was established in order to measuring the acidity of yogurt rapidly. 27 samples selected separately from five different brands of yogurt were measured by Vis/NIR-spectroscopy. The pH of yogurt on positions scanned by spectrum was measured by a pH meter. The mathematical model between pH and Vis/NIR spectral measurements was established and developed based on partial least squares (PLS) by using Unscramble V9.2. Then 25 unknown samples from 5 different brands were predicted based on the mathematical model. The result shows that The correlation coefficient of pH based on PLS model is more than 0.890, and standard error of calibration (SEC) is 0.037, standard error of prediction (SEP) is 0.043. Through predicting the pH of 25 samples of yogurt from 5 different brands, the correlation coefficient between predictive value and measured value of those samples is more than 0918. The results show the good to excellent prediction performances. The Vis/NIR spectroscopy technique had a significant greater accuracy for determining the value of pH. It was concluded that the VisINIRS measurement technique can be used to measure pH of yogurt fast and accurately, and a new method for the measurement of pH of yogurt was established.

  20. Evaluation of a new disposable silicon limbal relaxing incision knife by experienced users

    OpenAIRE

    Parvu Valentin; Dugue Geoffrey; Albanese John; Bajart Ann M; Lee Edwin

    2009-01-01

    Abstract Background Previous research has suggested that the silicon BD Atomic Edge™ knife has superior performance characteristics when compared to a metal knife and performance similar to diamond knife when making various incisions. This study was designed to determine whether a silicon accurate depth knife has equivalent performance characteristics when compared to a diamond limbal relaxing incision (LRI) knife and superior performance characteristics when compared to a steel accurate dept...

  1. Characteristics of Bone Injuries Resulting from Knife Wounds Incised with Different Forces.

    Science.gov (United States)

    Humphrey, Caitlin; Kumaratilake, Jaliya; Henneberg, Maciej

    2017-11-01

    The aim of this research was to experimentally determine the characteristics of incised bone wounds, which are commonly found in defense injuries. A specially constructed pivoting arm device was used to inflict wounds with controlled forces and direction. Five knives were selected to inflict the wounds on porcine forelimbs. Eight incised wounds were made per knife per force. A larger knife and a greater force caused longer and wider bone wounds. Comparisons of individual knives at the two forces produced varying results in the bone wounds. A correlation was seen between the force and the length (r = 0.69), width (r = 0.63), and depth (r = 0.57) of bone wounds. Serrated-edge and nonserrated knives can be distinguished from the appearance of the wound. The outcomes may be applicable in forensic investigations to ascertain the forces associated with incised wounds and identify the specific knife used. © 2017 American Academy of Forensic Sciences.

  2. NIR spectroscopic properties of aqueous acids solutions.

    Science.gov (United States)

    Omar, Ahmad Fairuz; Atan, Hanafi; Matjafri, Mohd Zubir

    2012-06-15

    Acid content is one of the important quality attributes in determining the maturity index of agricultural product, particularly fruits. Despite the fact that much research on the measurement of acidity in fruits through non-destructive spectroscopy analysis at NIR wavelengths between 700 to 1,000 nm has been conducted, the same response towards individual acids is not well known. This paper presents NIR spectroscopy analysis on aqueous citric, tartaric, malic and oxalic solutions through quantitative analysis by selecting a set of wavelengths that can best be used to measure the pH of the solutions. The aquaphotomics study of the acid solutions has generated R² above 0.9 for the measurement of all acids. The most important wavelengths for pH are located at 918-925 nm and 990-996 nm, while at 975 nm for water.

  3. Small-incision lenticule extraction (SMILE)

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    2016-01-01

    surgery was 0.07 ± 0.03 (logMAR). However, 12 eyes (1.6 %) lost 2 or more lines of CDVA from before surgery to 3 months postoperatively. Simultaneous treatment of up to 3.00 D of astigmatism was not associated with less predictable refractive outcomes. CONCLUSIONS: In the short term, SMILE seemed......PURPOSE: To study the outcomes of small-incision lenticule extraction (SMILE) for treatment of myopia and myopic astigmatism. METHODS: Retrospective study of patients treated for myopia or myopic astigmatism with SMILE, using a VisuMax(®) femtosecond laser (Carl Zeiss Meditec, Jena, Germany...

  4. Dynamic Filtering Improves Attentional State Prediction with fNIRS

    Science.gov (United States)

    Harrivel, Angela R.; Weissman, Daniel H.; Noll, Douglas C.; Huppert, Theodore; Peltier, Scott J.

    2016-01-01

    Brain activity can predict a person's level of engagement in an attentional task. However, estimates of brain activity are often confounded by measurement artifacts and systemic physiological noise. The optimal method for filtering this noise - thereby increasing such state prediction accuracy - remains unclear. To investigate this, we asked study participants to perform an attentional task while we monitored their brain activity with functional near infrared spectroscopy (fNIRS). We observed higher state prediction accuracy when noise in the fNIRS hemoglobin [Hb] signals was filtered with a non-stationary (adaptive) model as compared to static regression (84% +/- 6% versus 72% +/- 15%).

  5. Single incision thoracoscopic sympathectomy for palmar and axillary hyperhidrosis

    Directory of Open Access Journals (Sweden)

    Aram Baram

    2014-02-01

    Full Text Available Background: Primary hyperhidrosis is characterized by excessive sweating beyond physiological needs. It is a common disease (incidence 2.8% that causes intense discomfort for patients. In the last decade, advantages of Single-Incision Thoracoscopic Sympathectomy have become clear, particularly in decreasing morbidity of sympathectomy. Patients and methods: From January 2010 to December 2012, 39 patients (29 females and 10 males with primary palmar or axillary hyperhidrosis were treated by thoracoscopic sympathectomy. The age ranged from 18 to 40 years with a mean of 26.28 years. We used single incision thoracoscopic electrocoagulation through 10 mm incision for thoracic sympathetic chain (T2–T4. Results: The mean follow-up was 23.6 ± 14.2 months (range = 4–24 months. A total of 97.42% of patients were satisfied with the results. A total of 72.5% of patients had cure, one patient (2.5% and another patient (2.5% presented with recurrent axillary hyperhidrosis. The morbidity was 10.2% with no mortality. Percentage of compensatory sweating and gustatory sweating were 5.1% (p = .353 and 2.5% (p = .552, respectively. The result of sympathectomy in patients with both palmar and axillary hyperhidrosis was significantly better (17, 43.58% compared to palmar type (14, 35.89% or axillary type (7, 17.94%. Conclusion: Thoracoscopic sympathectomy is a simple, safe, and cost-effective therapy with good results and low complications.

  6. [Real-time detection of quality of Chinese materia medica: strategy of NIR model evaluation].

    Science.gov (United States)

    Wu, Zhi-sheng; Shi, Xin-yuan; Xu, Bing; Dai, Xing-xing; Qiao, Yan-jiang

    2015-07-01

    The definition of critical quality attributes of Chinese materia medica ( CMM) was put forward based on the top-level design concept. Nowadays, coupled with the development of rapid analytical science, rapid assessment of critical quality attributes of CMM was firstly carried out, which was the secondary discipline branch of CMM. Taking near infrared (NIR) spectroscopy as an example, which is a rapid analytical technology in pharmaceutical process over the past decade, systematic review is the chemometric parameters in NIR model evaluation. According to the characteristics of complexity of CMM and trace components analysis, a multi-source information fusion strategy of NIR model was developed for assessment of critical quality attributes of CMM. The strategy has provided guideline for NIR reliable analysis in critical quality attributes of CMM.

  7. Characterization of oxidative guanine damage and repair in mammalian telomeres.

    Directory of Open Access Journals (Sweden)

    Zhilong Wang

    2010-05-01

    Full Text Available 8-oxo-7,8-dihydroguanine (8-oxoG and 2,6-diamino-4-hydroxy-5-formamidopyrimidine (FapyG are among the most common oxidative DNA lesions and are substrates for 8-oxoguanine DNA glycosylase (OGG1-initiated DNA base excision repair (BER. Mammalian telomeres consist of triple guanine repeats and are subject to oxidative guanine damage. Here, we investigated the impact of oxidative guanine damage and its repair by OGG1 on telomere integrity in mice. The mouse cells were analyzed for telomere integrity by telomere quantitative fluorescence in situ hybridization (telomere-FISH, by chromosome orientation-FISH (CO-FISH, and by indirect immunofluorescence in combination with telomere-FISH and for oxidative base lesions by Fpg-incision/Southern blot assay. In comparison to the wild type, telomere lengthening was observed in Ogg1 null (Ogg1(-/- mouse tissues and primary embryonic fibroblasts (MEFs cultivated in hypoxia condition (3% oxygen, whereas telomere shortening was detected in Ogg1(-/- mouse hematopoietic cells and primary MEFs cultivated in normoxia condition (20% oxygen or in the presence of an oxidant. In addition, telomere length abnormalities were accompanied by altered telomere sister chromatid exchanges, increased telomere single- and double-strand breaks, and preferential telomere lagging- or G-strand losses in Ogg1(-/- mouse cells. Oxidative guanine lesions were increased in telomeres in Ogg1(-/- mice with aging and primary MEFs cultivated in 20% oxygen. Furthermore, oxidative guanine lesions persisted at high level in Ogg1(-/- MEFs after acute exposure to hydrogen peroxide, while they rapidly returned to basal level in wild-type MEFs. These findings indicate that oxidative guanine damage can arise in telomeres where it affects length homeostasis, recombination, DNA replication, and DNA breakage repair. Our studies demonstrate that BER pathway is required in repairing oxidative guanine damage in telomeres and maintaining telomere integrity

  8. Study on feasibility of determination of glucosamine content of fermentation process using a micro NIR spectrometer.

    Science.gov (United States)

    Sun, Zhongyu; Li, Can; Li, Lian; Nie, Lei; Dong, Qin; Li, Danyang; Gao, Lingling; Zang, Hengchang

    2018-08-05

    N-acetyl-d-glucosamine (GlcNAc) is a microbial fermentation product, and NIR spectroscopy is an effective process analytical technology (PAT) tool in detecting the key quality attribute: the GlcNAc content. Meanwhile, the design of NIR spectrometers is under the trend of miniaturization, portability and low-cost nowadays. The aim of this study was to explore a portable micro NIR spectrometer with the fermentation process. First, FT-NIR spectrometer and Micro-NIR 1700 spectrometer were compared with simulated fermentation process solutions. The R c 2 , R p 2 , RMSECV and RMSEP of the optimal FT-NIR and Micro-NIR 1700 models were 0.999, 0.999, 3.226 g/L, 1.388 g/L and 0.999, 0.999, 1.821 g/L, 0.967 g/L. Passing-Bablok regression method and paired t-test results showed there were no significant differences between the two instruments. Then the Micro-NIR 1700 was selected for the practical fermentation process, 135 samples from 10 batches were collected. Spectral pretreatment methods and variables selection methods (BiPLS, FiPLS, MWPLS and CARS-PLS) for PLS modeling were discussed. The R c 2 , R p 2 , RMSECV and RMSEP of the optimal GlcNAc content PLS model of the practical fermentation process were 0.994, 0.995, 2.792 g/L and 1.946 g/L. The results have a positive reference for application of the Micro-NIR spectrometer. To some extent, it could provide theoretical supports in guiding the microbial fermentation or the further assessment of bioprocess. Copyright © 2018. Published by Elsevier B.V.

  9. Treatment for incarcerated indirect hernia with “Cross-Internal Ring” inguinal oblique incision in children

    Directory of Open Access Journals (Sweden)

    Xue-Qiang Yan

    2017-01-01

    Full Text Available Background: This study aims to evaluate the utility of the “Cross-Internal Ring” inguinal oblique incision for the surgical treatment of incarcerated indirect hernia (IIH complicated with severe abdominal distension. Materials and Methods: Patients of IIH complicated with severe abdominal distension were reviewed retrospectively. All patients received operation through the “Cross-Internal Ring” inguinal oblique incision. Results: There were totally 13 patients were included, male to female ratio was 9-4. The time for patients to resume oral feeding varying from 2 to 5 days after operation, no complications include delayed intestinal perforation, intra-abdominal abscess, and incision infection happened. Average postoperative hospital stay was 5.2 days. All cases were followed up for 6–18 months. No recurrence or iatrogenic cryptorchidism happened. Conclusion: “Cross-Internal Ring” inguinal oblique incision is a simple, safe, and reliable surgical method to treat pediatric IIH complicated with severe abdominal distension.

  10. The impact of cleft lip and palate repair on maxillofacial growth.

    Science.gov (United States)

    Shi, Bing; Losee, Joseph E

    2015-03-23

    Surgical correction is central to current team-approached cleft treatment. Cleft surgeons are always concerned about the impact of their surgical maneuver on the growth of the maxilla. Hypoplastic maxilla, concaved mid-face and deformed dental arch have constantly been reported after cleft treatments. It is very hard to completely circumvent these postoperative complications by current surgical protocols. In this paper, we discussed the factors that inhibit the maxillofacial growth on cleft patients. These factors included pre-surgical intervention, the timing of cleft palate and alveolae repair, surgical design and treatment protocol. Also, we made a review about the influence on the maxillary growth in un-operated cleft patients. On the basis of previous researches, we can conclude that most of scholars express identity of views in these aspects: early palatoplasty lead to maxilla growth inhibition in all dimensions; secondary alveolar bone graft had no influence on maxilla sagittal growth; cleft lip repair inhibited maxilla sagittal length in patients with cleft lip and palate; Veau's pushback palatoplasty and Langenbeck's palatoplasty with relaxing incisions were most detrimental to growth; Furlow palatoplasty showed little detrimental effect on maxilla growth; timing of hard palate closure, instead of the sequence of hard or soft palate repair, determined the postoperative growth. Still, scholars hold controversial viewpoints in some issues, for example, un-operated clefts have normal growth potential or not, pre-surgical intervention and pharyngoplasty inhibited maxillofacial growth or not.

  11. The impact of cleft lip and palate repair on maxillofacial growth

    Science.gov (United States)

    Shi, Bing; Losee, Joseph E

    2015-01-01

    Surgical correction is central to current team-approached cleft treatment. Cleft surgeons are always concerned about the impact of their surgical maneuver on the growth of the maxilla. Hypoplastic maxilla, concaved mid-face and deformed dental arch have constantly been reported after cleft treatments. It is very hard to completely circumvent these postoperative complications by current surgical protocols. In this paper, we discussed the factors that inhibit the maxillofacial growth on cleft patients. These factors included pre-surgical intervention, the timing of cleft palate and alveolae repair, surgical design and treatment protocol. Also, we made a review about the influence on the maxillary growth in un-operated cleft patients. On the basis of previous researches, we can conclude that most of scholars express identity of views in these aspects: early palatoplasty lead to maxilla growth inhibition in all dimensions; secondary alveolar bone graft had no influence on maxilla sagittal growth; cleft lip repair inhibited maxilla sagittal length in patients with cleft lip and palate; Veau's pushback palatoplasty and Langenbeck's palatoplasty with relaxing incisions were most detrimental to growth; Furlow palatoplasty showed little detrimental effect on maxilla growth; timing of hard palate closure, instead of the sequence of hard or soft palate repair, determined the postoperative growth. Still, scholars hold controversial viewpoints in some issues, for example, un-operated clefts have normal growth potential or not, pre-surgical intervention and pharyngoplasty inhibited maxillofacial growth or not. PMID:25394591

  12. Fluorescence detection of glutathione and oxidized glutathione in blood with a NIR-excitable cyanine probe

    Science.gov (United States)

    Liu, Chang-hui; Qi, Feng-pei; Wen, Fu-bin; Long, Li-ping; Liu, Ai-juan; Yang, Rong-hua

    2018-04-01

    Cyanine has been widely utilized as a near infrared (NIR) fluorophore for detection of glutathione (GSH). However, the excitation of most of the reported cyanine-based probes was less than 800 nm, which inevitably induce biological background absorption and lower the sensitivity, limiting their use for detection of GSH in blood samples. To address this issue, here, a heptamethine cyanine probe (DNIR), with a NIR excitation wavelength at 804 nm and a NIR emission wavelength at 832 nm, is employed for the detection of GSH and its oxidized form (GSSG) in blood. The probe displays excellent selectivity for GSH over GSSG and other amino acids, and rapid response to GSH, in particular a good property for indirect detection of GSSG in the presence of enzyme glutathione reductase and the reducing agent nicotinamideadenine dinucleotide phosphate, without further separation prior to fluorescent measurement. To the best of our knowledge, this is the first attempt to explore NIR fluorescent approach for the simultaneous assay of GSH and GSSG in blood. As such, we expect that our fluorescence sensors with both NIR excitation and NIR emission make this strategy suitable for the application in complex physiological systems.

  13. Effects of Bank Vegetation and Incision on Erosion Rates in an Urban Stream

    Directory of Open Access Journals (Sweden)

    Emily Arnold

    2018-04-01

    Full Text Available Changing land-use associated with urbanization has resulted in shifts in riparian assemblages, stream hydraulics, and sediment dynamics leading to the degradation of waterways. To combat degradation, restoration and management of riparian zones is becoming increasingly common. However, the relationship between flora, especially the influence of invasive species, on sediment dynamics is poorly understood. Bank erosion and turbidity were monitored in the Tookany Creek and its tributary Mill Run in the greater Philadelphia, PA region. To evaluate the influence of the invasive species Reynoutria japonica (Japanese knotweed on erosion, reaches were chosen based on their riparian vegetation and degree of incision. Bank pins and turbidity loggers were used to estimate sediment erosion. Erosion calculations based on bank pins suggest greater erosion in reaches dominated by knotweed than those dominated by trees. For a 9.5-month monitoring period, there was 29 cm more erosion on banks that were also incised, and 9 cm more erosion in banks with little incision. Turbidity responses to storm events were also higher (77 vs. 54 NTU (nephelometric turbidity unit in reaches with knotweed, although this increase was found when the reach dominated by knotweed was also incised. Thus, this study linked knotweed to increased erosion using multiple methods.

  14. Determination of soil content in chlordecone (organochlorine pesticide) using near infrared reflectance spectroscopy (NIRS)

    International Nuclear Information System (INIS)

    Brunet, Didier; Woignier, Thierry; Lesueur-Jannoyer, Magalie; Achard, Raphael; Rangon, Luc; Barthes, Bernard G.

    2009-01-01

    Chlordecone is a toxic organochlorine insecticide that was used in banana plantations until 1993 in the French West Indies. This study aimed at assessing the potential of near infrared reflectance spectroscopy (NIRS) for determining chlordecone content in Andosols, Nitisols and Ferralsols from Martinique. Using partial least square regression, chlordecone content conventionally determined through gas chromatography-mass spectrometry could be correctly predicted by NIRS (Q 2 = 0.75, R 2 = 0.82 for the total set), especially for samples with chlordecone content -1 or when the sample set was rather homogeneous (Q 2 = 0.91, R 2 = 0.82 for the Andosols). Conventional measures and NIRS predictions were poorly correlated for chlordecone content >12 mg kg -1 , nevertheless ca. 80% samples were correctly predicted when the set was divided into three or four classes of chlordecone content. Thus NIRS could be considered a time- and cost-effective method for characterising soil contamination by chlordecone. - Soil content in chlordecone, an organochlorine insecticide, can be determined time- and cost-effectively using near infrared reflectance spectroscopy (NIRS).

  15. Determination of soil content in chlordecone (organochlorine pesticide) using near infrared reflectance spectroscopy (NIRS)

    Energy Technology Data Exchange (ETDEWEB)

    Brunet, Didier, E-mail: didier.brunet@ird.f [IRD - Institut de Recherche pour le Developpement, UMR Eco and Sols (Ecologie Fonctionnelle et Biogeochimie des Sols), Montpellier SupAgro, Batiment 12, 2 place Viala, 34060 Montpellier Cedex 1 (France); Woignier, Thierry [IRD, UMR Eco and Sols, PRAM (Pole de Recherche Agronomique de la Martinique), BP 213, Petit Morne, 97232 Le Lamentin, Martinique (French West Indies) (France); CNRS - Centre National de la Recherche Scientifique, Universite Montpellier 2, place Eugene Bataillon, 34095 Montpellier Cedex 5 (France); Lesueur-Jannoyer, Magalie; Achard, Raphael [CIRAD (Centre de Cooperation Internationale en Recherche Agronomique pour le Developpement), PRAM, BP 213, Petit Morne, 97232 Le Lamentin, Martinique (French West Indies) (France); Rangon, Luc [IRD, UMR Eco and Sols, PRAM (Pole de Recherche Agronomique de la Martinique), BP 213, Petit Morne, 97232 Le Lamentin, Martinique (French West Indies) (France); Barthes, Bernard G. [IRD - Institut de Recherche pour le Developpement, UMR Eco and Sols (Ecologie Fonctionnelle et Biogeochimie des Sols), Montpellier SupAgro, Batiment 12, 2 place Viala, 34060 Montpellier Cedex 1 (France)

    2009-11-15

    Chlordecone is a toxic organochlorine insecticide that was used in banana plantations until 1993 in the French West Indies. This study aimed at assessing the potential of near infrared reflectance spectroscopy (NIRS) for determining chlordecone content in Andosols, Nitisols and Ferralsols from Martinique. Using partial least square regression, chlordecone content conventionally determined through gas chromatography-mass spectrometry could be correctly predicted by NIRS (Q{sup 2} = 0.75, R{sup 2} = 0.82 for the total set), especially for samples with chlordecone content <12 mg kg{sup -1} or when the sample set was rather homogeneous (Q{sup 2} = 0.91, R{sup 2} = 0.82 for the Andosols). Conventional measures and NIRS predictions were poorly correlated for chlordecone content >12 mg kg{sup -1}, nevertheless ca. 80% samples were correctly predicted when the set was divided into three or four classes of chlordecone content. Thus NIRS could be considered a time- and cost-effective method for characterising soil contamination by chlordecone. - Soil content in chlordecone, an organochlorine insecticide, can be determined time- and cost-effectively using near infrared reflectance spectroscopy (NIRS).

  16. Anterior temporal artery tap to identify systemic interference using short-separation NIRS measurements

    DEFF Research Database (Denmark)

    Sood, Mehak; Jindal, Utkarsh; Chowdhury, Shubhajit Roy

    2015-01-01

    that are also affected by tDCS. An approach may be to use short optode separations to measure systemic hemodynamic fluctuations occurring in the superficial layers which can then be used as regressors to remove the systemic contamination. Here, we demonstrate that temporal artery tap may be used to better...... of neural activity is possible with a measure of cerebral hemoglobin oxygenation using near-infrared spectroscopy (NIRS). In principal accordance, NIRS can capture the hemodynamic response to tDCS but the challenge remains in removing the systemic interference occurring in the superficial layers of the head...... identify systemic interference using this short-separation NIRS. Moreover, NIRS-EEG joint-imaging during anodal tDCS was used to measure changes in mean cerebral haemoglobin oxygen saturation (rSO2) along with changes in the log-transformed mean-power of EEG within 0.5 Hz-11.25 Hz. We found that percent...

  17. [Cleft palate repair with a combined method of mucosal flap pushback of the hard palate].

    Science.gov (United States)

    Zhao, Z; Li, S; Xu, J

    1996-03-01

    From January of 1992, we applied a combined method to repair cleft palate in 20 patients and received satisfactory results. The method is characterized by pushing back the mucosal flap of the hard palate, a Z-plasty on the nasal mucosa, repositioning the levator muscle to lengthen the palate, circumferential pharyng oplasty using denervated extensor hallucis brevis muscle, without making relaxing incisions and elevating the mucoperiosteal flap, avoiding interference to the greater and lesser palatine vessels and nerves, without relaxing palatal aponeurosis. The advantages of this method are preserving the normal anatomy and function of the palate and nasopharyngeal cavity, improving the function of velopharyngeal closure and minimizing secondary deformities.

  18. Characterization of DNA substrate specificities of apurinic/apyrimidinic endonucleases from Mycobacterium tuberculosis.

    Science.gov (United States)

    Abeldenov, Sailau; Talhaoui, Ibtissam; Zharkov, Dmitry O; Ishchenko, Alexander A; Ramanculov, Erlan; Saparbaev, Murat; Khassenov, Bekbolat

    2015-09-01

    Apurinic/apyrimidinic (AP) endonucleases are key enzymes involved in the repair of abasic sites and DNA strand breaks. Pathogenic bacteria Mycobacterium tuberculosis contains two AP endonucleases: MtbXthA and MtbNfo members of the exonuclease III and endonuclease IV families, which are exemplified by Escherichia coli Xth and Nfo, respectively. It has been shown that both MtbXthA and MtbNfo contain AP endonuclease and 3'→5' exonuclease activities. However, it remains unclear whether these enzymes hold 3'-repair phosphodiesterase and nucleotide incision repair (NIR) activities. Here, we report that both mycobacterial enzymes have 3'-repair phosphodiesterase and 3'-phosphatase, and MtbNfo contains in addition a very weak NIR activity. Interestingly, depending on pH, both enzymes require different concentrations of divalent cations: 0.5mM MnCl2 at pH 7.6 and 10 mM at pH 6.5. MtbXthA requires a low ionic strength and 37 °C, while MtbNfo requires high ionic strength (200 mM KCl) and has a temperature optimum at 60 °C. Point mutation analysis showed that D180 and N182 in MtbXthA and H206 and E129 in MtbNfo are critical for enzymes activities. The steady-state kinetic parameters indicate that MtbXthA removes 3'-blocking sugar-phosphate and 3'-phosphate moieties at DNA strand breaks with an extremely high efficiency (kcat/KM=440 and 1280 μM(-1)∙min(-1), respectively), while MtbNfo exhibits much lower 3'-repair activities (kcat/KM=0.26 and 0.65 μM(-1)∙min(-1), respectively). Surprisingly, both MtbXthA and MtbNfo exhibited very weak AP site cleavage activities, with kinetic parameters 100- and 300-fold lower, respectively, as compared with the results reported previously. Expression of MtbXthA and MtbNfo reduced the sensitivity of AP endonuclease-deficient E. coli xth nfo strain to methylmethanesulfonate and H2O2 to various degrees. Taken together, these data establish the DNA substrate specificity of M. tuberculosis AP endonucleases and suggest their possible role

  19. Analysis of the distribution of DNA repair patches in the DNA-nuclear matrix complex from human cells

    International Nuclear Information System (INIS)

    Mullenders, L.H.F.

    1983-01-01

    The distribution of ultraviolet-induced repair patches along DNA loops attached to the nuclear matrix, was investigated by digestion with DNA-degrading enzymes and neutral sucrose gradient centrifugation. When DNA was gradually removed by DNAase 1, pulse label incorporated by ultraviolet-irradiated cells during 10 min in the presence of hydroxyurea or hydroxyurea/arabinosylcytosine showed similar degradation kinetics as prelabelled DNA. No preferential association of pulse label with the nuclear matrix was observed, neither within 30 min nor 13 h after iiradiation. When the pulse label was incorporated by replicative synthesis under the same conditions, a preferential association of newly-synthesized DNA with the nuclear matrix was observed. Single-strand specific digestion with nuclease S 1 of nuclear lysates from ultraviolet-irradiated cells, pulse labelled in the presence of hydroxyurea/arabinosylcytosine, caused a release of about 70% of the prelabelled DNA and 90% of the pulse-labelled DNA from the rapidly sedimenting material in sucrose gradients. The results suggest no specific involvement of the nuclear matrix in repair synthesis, a random distribution of repair patches along the DNA loops, and simultaneously multiple incision events per DNA loop. (Auth.)

  20. Analysis of the distribution of DNA repair patches in the DNA-nuclear matrix complex from human cells

    Energy Technology Data Exchange (ETDEWEB)

    Mullenders, L.H.F. (Rijksuniversiteit Leiden (Netherlands). Lab. voor Stralengenetica en Chemische Mutagenese); Zeeland, A.A. van; Natarajan, A.T. (Cohen (J.A.) Inst. voor Radiopathologie en Stralenbescherming, Leiden (Netherlands))

    1983-09-09

    The distribution of ultraviolet-induced repair patches along DNA loops attached to the nuclear matrix, was investigated by digestion with DNA-degrading enzymes and neutral sucrose gradient centrifugation. When DNA was gradually removed by DNAase 1, pulse label incorporated by ultraviolet-irradiated cells during 10 min in the presence of hydroxyurea or hydroxyurea/arabinosylcytosine showed similar degradation kinetics as prelabelled DNA. No preferential association of pulse label with the nuclear matrix was observed, neither within 30 min nor 13 h after irradiation. When the pulse label was incorporated by replicative synthesis under the same conditions, a preferential association of newly-synthesized DNA with the nuclear matrix was observed. Single-strand specific digestion with nuclease S/sub 1/ of nuclear lysates from ultraviolet-irradiated cells, pulse labelled in the presence of hydroxyurea/arabinosylcytosine, caused a release of about 70% of the prelabelled DNA and 90% of the pulse-labelled DNA from the rapidly sedimenting material in sucrose gradients. The results suggest no specific involvement of the nuclear matrix in repair synthesis, a random distribution of repair patches along the DNA loops, and simultaneously multiple incision events per DNA loop.

  1. Cost assessment of instruments for single-incision laparoscopic cholecystectomy

    DEFF Research Database (Denmark)

    Henriksen, Nadia A; Al-Tayar, Haytham; Rosenberg, Jacob

    2012-01-01

    Specially designed surgical instruments have been developed for single-incision laparoscopic surgery, but high instrument costs may impede the implementation of these procedures. The aim of this study was to compare the cost of operative implements used for elective cholecystectomy performed...

  2. Fluorescence enhancing under UV-NIR simultaneous-excitation in ZnS:Cu,Mn phosphors

    Directory of Open Access Journals (Sweden)

    L. J. Xie

    2012-12-01

    Full Text Available The fluorescence properties of a long-lasting phosphor, ZnS:Cu,Mn was studied for the first time under simultaneously excitation of both UV and NIR light. Up to 20% fluorescence enhancement of the phosphor was observed. In the present simultaneously-excitation process, broad-band NIR light was absorbed and converted to visible photons via a single-photon upconversion path. We propose that a novel kind of spectral-conversion material with the unique ability to simultaneously convert both UV and NIR photons can be developed and is promising in the application of enhancing the EQE of solar cells.

  3. Catheter Ablation of a Complex Atrial Tachycardia after Surgical Repair of Tetralogy of Fallot Guided by Combined Noncontact and Contact Mapping

    Directory of Open Access Journals (Sweden)

    Eitaro Fujii, MD

    2010-01-01

    Full Text Available A 34-year-old man with a surgically repaired Tetralogy of Fallot complained of palpitation, fatigue, and presyncope. A 12-lead ECG showed atrial tachycardia with a cycle length of 250 ms and a P wave morphology positive in leads II, III and aVF, and negative in lead V1. Although the EnSite system (version 6.OJ made use of noncontact mapping to delineate the counterclockwise reentry around the crista tenninalis, it was difficult to rule out the incisional atrial reentry because the location of the surgical incision was far from the multi-electrode array. Since the bipolar contact mapping of the EnSite system revealed the location of the atriotomy incision, entrainment mapping during the tachycardia demonstrated the critical reentry circuit around the crista terminalis. Radiofrequency ablation targeting the critical isthmus from the lower position of the crista terminalis to the posterior dense scar which was continuous with the inferior vena cava, and to the atriotomy scar, eliminated the tachycardia.

  4. Single-trial lie detection using a combined fNIRS-polygraph system

    Science.gov (United States)

    Bhutta, M. Raheel; Hong, Melissa J.; Kim, Yun-Hee; Hong, Keum-Shik

    2015-01-01

    Deception is a human behavior that many people experience in daily life. It involves complex neuronal activities in addition to several physiological changes in the body. A polygraph, which can measure some of the physiological responses from the body, has been widely employed in lie-detection. Many researchers, however, believe that lie detection can become more precise if the neuronal changes that occur in the process of deception can be isolated and measured. In this study, we combine both measures (i.e., physiological and neuronal changes) for enhanced lie-detection. Specifically, to investigate the deception-related hemodynamic response, functional near-infrared spectroscopy (fNIRS) is applied at the prefrontal cortex besides a commercially available polygraph system. A mock crime scenario with a single-trial stimulus is set up as a deception protocol. The acquired data are classified into “true” and “lie” classes based on the fNIRS-based hemoglobin-concentration changes and polygraph-based physiological signal changes. Linear discriminant analysis is utilized as a classifier. The results indicate that the combined fNIRS-polygraph system delivers much higher classification accuracy than that of a singular system. This study demonstrates a plausible solution toward single-trial lie-detection by combining fNIRS and the polygraph. PMID:26082733

  5. Single-trial lie detection using a combined fNIRS-polygraph system

    Directory of Open Access Journals (Sweden)

    M. Raheel eBhutta

    2015-06-01

    Full Text Available Deception is a human behavior that many people experience in daily life. It involves complex neuronal activities in addition to several physiological changes in the body. A polygraph, which can measure some of the physiological responses from the body, has been widely employed in lie-detection. Many researchers, however, believe that lie detection can become more precise if the neuronal changes that occur in the process of deception can be isolated and measured. In this study, we combine both measures (i.e., physiological and neuronal changes for enhanced lie-detection. Specifically, to investigate the deception-related hemodynamic response, functional near-infrared spectroscopy (fNIRS is applied at the prefrontal cortex besides a commercially available polygraph system. A mock crime scenario with a single-trial stimulus is set up as a deception protocol. The acquired data are classified into true and lie classes based on the fNIRS-based hemoglobin-concentration changes and polygraph-based physiological signal changes. Linear discriminant analysis is utilized as a classifier. The results indicate that the combined fNIRS-polygraph system delivers much higher classification accuracy than that of a singular system. This study demonstrates a plausible solution toward single-trial lie-detection by combining fNIRS and the polygraph.

  6. [Pedicled superior gluteal artery perforator bilateral quadrilobed flaps for repair of large sacrococcygeal pressure sores].

    Science.gov (United States)

    Hai, Henglin; Li, Huatao; Chen, Yang; Li, Qiang; Wu, Shenggang; Lili, Wang; Yan, Lei; Xiaoying, Zhou

    2013-03-01

    To investigate the effectiveness of pedicled superior gluteal artery perforator bilateral quadrilobed flaps for repairing large sacrococcygeal pressure sores. Between June 2003 and August 2011, 6 paraplegia patients with large sacrococcygeal pressure sores were repaired with the pedicled superior gluteal artery perforator bilateral quadrilobed flaps. There were 2 males and 4 females with an average age of 45.6 years (range, 37-62 years). The mean disease duration was 8.4 months (range, 3-26 months). According to National Pressure Ulcer Advisory Panel (NPUAP) standard, 6 cases rated as degree IV. The size of pressure sores ranged from 15 cm x 13 cm to 18 cm x 16 cm. The size of flaps ranged from 18 cm x 14 cm to 21 cm x 15 cm. After operation, all flaps survived successfully. The wounds healed by first intention in 5 cases; partial dehiscence of incision occurred in 1 case, which was cured after dressing change for 26 days. Six patients were followed up 6-24 months (mean, 12.5 months). The appearance and texture of the flaps were smooth and soft with good elasticity and no ulceration. Pedicled superior gluteal artery perforator bilateral quadrilobed flaps can repair large sacrococcygeal pressure sores. The appearance of flaps is smooth and has good compression-resistance effect.

  7. Microincision versus small-incision coaxial cataract surgery using different power modes for hard nuclear cataract.

    Science.gov (United States)

    Kim, Eun Chul; Byun, Yong Soo; Kim, Man Soo

    2011-10-01

    To compare the efficacy of microincision and small-incision coaxial phacoemulsification in treating hard cataracts using different ultrasound power modes. Department of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea. Randomized clinical trial. Eyes with hard cataract were randomized to have an initial incision of 1.80 mm, 2.20 mm, or 2.75 mm. The eyes in each group were equally randomized to treatment with burst, pulse, or continuous mode. Ultrasound time (UST), mean cumulative dissipated energy (CDE), corrected distance visual acuity (CDVA), surgically induced corneal astigmatism, incisional and central corneal thickness (CCT), and endothelial cell counts were evaluated. The study enrolled 180 eyes, 60 in each group. Two months postoperatively, there were no statistically significant differences in UST, CDE, CDVA, CCT, or percentage endothelial cell loss between the 3 incision groups. The 2.75 mm incision induced more astigmatism at 2 months and less incisional corneal edema at 1 week than the 1.80 mm or 2.20 mm incision (Phard cataract. The intraoperative energy use and ocular damage was less with the pulse and burst modes than with the continuous mode. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Monitoring of whey quality with NIR spectroscopy

    DEFF Research Database (Denmark)

    Kucheryavskiy, Sergey; Lomborg, Carina

    2015-01-01

    The possibility of using near-infrared (NIR) spectroscopy for monitoring of liquid whey quality parameters during protein production process has been tested. The parameters included total solids, lactose, protein and fat content. The samples for the experiment were taken from real industrial...

  9. Relationship between muscle oxygenation by NIRS and blood lactate

    Energy Technology Data Exchange (ETDEWEB)

    Xu Guodong [School of Physical Education, Jianghan University, Hubei Wuhan 430056 (China); Mao Zongzhen; Ye Yanjie; Lv Kunru, E-mail: xguodong@wipe.edu.cn [School of Health Sciences, Wuhan Institute of Physical Education, Hubei Wuhan 430079 (China)

    2011-01-01

    The aim of the study was to investigate the relationship of muscle oxygenation in term of oxy-hemoglobin concentration change ({Delta}HbO{sub 2}) by NIRS and blood lactate (BLA) in local skeletal muscle and evaluate the capability of NIRS in the research of exercise physiology Twenty-three athlete in the national fin-swimming team took the increasing load training on the power bicycle while their {Delta}HbO{sub 2} and BLA were simultaneously recorded. The initial powers used in the training were set as 100 w for males and 40 w for females. During the experiment, the power kept constant for 3 min before each abrupt increment of 30 w until the limit of the athlete's capability. Statistical analysis and data visualization were performed. Following the increasing load training, {Delta}HbO{sub 2} step-likely increased in the phase of aerobic metabolism but linearly decreased in the phase of anaerobic metabolism. The variation tendency of BLA was the same as {Delta}HbO{sub 2} and the concurrency of crucial turning points between {Delta}HbO{sub 2} and BLA was revealed. This relationship between {Delta}HbO{sub 2} and BLA presented in the increasing load training suggested that {Delta}HbO{sub 2} might be capable for taking the place of the invasively measured parameter BLA. Considering that {Delta}HbO{sub 2} can be noninvasively measured by NIRS, {Delta}HbO{sub 2} has the potential in the evaluation of athletes' physiological function and training effect on the athletes and accordingly NIRS can be well used in this field.

  10. Comparison of incision and drainage against needle aspiration for the treatment of breast abscess.

    Science.gov (United States)

    Naeem, Muhammad; Rahimnajjad, Muhammad Kazim; Rahimnajjad, Nasir Ali; Ahmed, Qazi Jalaluddin; Fazel, Pyar Ali; Owais, Muhammad

    2012-11-01

    We aim to compare the incision and drainage against ultrasound-guided aspiration for the treatment of breast abscesses. Sixty-four patients were randomly allocated to Group A (incision and drainage) and Group B (needle aspiration). Incision and drainage was done under general, whereas aspiration was done under local anesthesia with antibiotic coverage after the pus sample was taken for cultures. Time taken to resolve symptoms including point tenderness, erythema and hyperthermia, recurrence of breast abscess, and healing time was recorded. Patients were followed until 8 weeks. Culture and sensitivity of the pus were done. Data were analyzed in SPSS 16.0. The mean difference of healing time was significant (P = 0.001). A total of 93.3 per cent were healed in Group B and 76.6 per cent in Group A (P = 0.033). Twenty-two samples (34.37%) had no bacterial yield and the remaining 42 samples (65.6%) yielded 11 anaerobic cultures (17.18%) and 31 aerobic cultures (48.4%). Ultrasound-guided aspiration of breast abscesses with the judicious use of antibiotics is a better treatment modality than incision and drainage.

  11. PENENTUAN BAHAN KERING BUAH SAWO SECARA TIDAK MERUSAK MENGGUNAKAN NIR SPECTROSCOPY

    Directory of Open Access Journals (Sweden)

    Diding Suhandy

    2012-12-01

    Full Text Available This work was conducted to develop a new measuring system for nondestructive dry matter prediction in sawo fruit using short wavelength near infrared (SW-NIR spectroscopy. In this research, a number of 100 sawo fruits were used as samples. Spectra were acquired using a portable spectrometer (VIS-NIR USB4000, The Ocean Optics, USA with 100 ms integration time and 50 scans for number of scanning. Dry matter was measured using oven drying. The calibration and validation model was developed using the partial least squares (PLS regression method. The result showed that the best calibration model could be developed for original spectra in the wavelength range of  700-990 nm with F= 8, r = 0.92, SEC = 0.68 and  SEP = 0.86. Keywords:   Absorbance mode, dry matter, nondestructive method, sawo fruit, SW-NIR spectroscopy.

  12. NIR hyperspectral compressive imager based on a modified Fabry–Perot resonator

    Science.gov (United States)

    Oiknine, Yaniv; August, Isaac; Blumberg, Dan G.; Stern, Adrian

    2018-04-01

    The acquisition of hyperspectral (HS) image datacubes with available 2D sensor arrays involves a time consuming scanning process. In the last decade, several compressive sensing (CS) techniques were proposed to reduce the HS acquisition time. In this paper, we present a method for near-infrared (NIR) HS imaging which relies on our rapid CS resonator spectroscopy technique. Within the framework of CS, and by using a modified Fabry–Perot resonator, a sequence of spectrally modulated images is used to recover NIR HS datacubes. Owing to the innovative CS design, we demonstrate the ability to reconstruct NIR HS images with hundreds of spectral bands from an order of magnitude fewer measurements, i.e. with a compression ratio of about 10:1. This high compression ratio, together with the high optical throughput of the system, facilitates fast acquisition of large HS datacubes.

  13. Quantification of fructan concentration in grasses using NIR spectroscopy and PLSR

    DEFF Research Database (Denmark)

    Shetty, Nisha; Gislum, Rene

    2011-01-01

    Near-infrared reflectance (NIR) spectroscopy combined with chemometrics was used to quantify fructan concentration in samples from seven grass species. Savitzky-Golay first derivative with filter width 7 and polynomial order 2 with mean centering was applied as a spectral pre-treatment method...... to remove unimportant baseline signals. In order to model the NIR spectroscopy data the partial least squares regression (PLSR) approach was used on the full spectra. Variable selection based on PLSR by jack-knifing within a cross-model validation (CMV) framework was applied in order to remove non...... quantification of fructans by NIR spectroscopy is possible and that jack-knifing PLSR within a CMV framework is an effective way to eliminate the wavelengths of no interest. Jack-knifing PLSR did not improve the predictive ability because the root mean square error of prediction (RMSEP) increased (1.37) compared...

  14. Non-contact finger vein acquisition system using NIR laser

    Science.gov (United States)

    Kim, Jiman; Kong, Hyoun-Joong; Park, Sangyun; Noh, SeungWoo; Lee, Seung-Rae; Kim, Taejeong; Kim, Hee Chan

    2009-02-01

    Authentication using finger vein pattern has substantial advantage than other biometrics. Because human vein patterns are hidden inside the skin and tissue, it is hard to forge vein structure. But conventional system using NIR LED array has two drawbacks. First, direct contact with LED array raise sanitary problem. Second, because of discreteness of LEDs, non-uniform illumination exists. We propose non-contact finger vein acquisition system using NIR laser and Laser line generator lens. Laser line generator lens makes evenly distributed line laser from focused laser light. Line laser is aimed on the finger longitudinally. NIR camera was used for image acquisition. 200 index finger vein images from 20 candidates are collected. Same finger vein pattern extraction algorithm was used to evaluate two sets of images. Acquired images from proposed non-contact system do not show any non-uniform illumination in contrary with conventional system. Also results of matching are comparable to conventional system. We developed Non-contact finger vein acquisition system. It can prevent potential cross contamination of skin diseases. Also the system can produce uniformly illuminated images unlike conventional system. With the benefit of non-contact, proposed system shows almost equivalent performance compared with conventional system.

  15. Ultrasonic diagnosis and transurethral incision of ureterocele with hydronephrosis

    DEFF Research Database (Denmark)

    Waaddegaard, P; Miskowiak, J; Stage, P

    1991-01-01

    In a 65-year-old woman with right-sided loin pain, ultrasonography revealed a grossly dilated and obstructed right pyelogram due to a 50-mm ureterocele. After transurethral lateral incision of the ureterocele, there was complete recovery without vesicoureteric reflux. Ultrasonography is advantage...

  16. Histomorphological and immunofluorescence evaluation of clear corneal incisions after microcoaxial phacoemulsification with 2.2 mm and 1.8 mm systems.

    Science.gov (United States)

    Vasavada, Abhay R; Johar, Kaid; Praveen, Mamidipudi R; Vasavada, Viraj A; Arora, Anshul I

    2013-04-01

    To compare changes in the incision's histomorphology and denaturation of collagen I in rabbit eyes having microcoaxial phacoemulsification through 2.2 mm and 1.8 mm incision-compatible systems. Randomized experimental trial. Iladevi Cataract & IOL Research Centre, Ahmedabad, India. Thirty rabbit eyes were randomized into Group 1 (microcoaxial phacoemulsification through 2.2 mm incisions using Infiniti system [torsional ultrasound]) and Group 2 (microcoaxial phacoemulsification through 1.8 mm incisions using Stellaris system [longitudinal ultrasound]). Each group was then divided into 3 subgroups of 5 eyes each based on 1 of the 3 intervention options: phacoemulsification only, intraocular lens (IOL) insertion only, and phacoemulsification with IOL insertion. Left eyes were randomized for microcoaxial phacoemulsification, and right eyes were treated as controls. After phacoemulsification, eyes in Group 1 showed loss of epithelium at the roof of the incisions and Descemet membrane detachment at the floor of the incisions. These findings did not change after IOL insertion. After phacoemulsification, eyes in Group 2 showed loss of epithelium, but Descemet membrane remained attached. There was a longitudinal split in the incision's stroma in the direction of internal entry. The stromal damage increased after IOL implantation. Immunofluorescence studies showed no obvious irregularities in the arrangement of collagen I in either group. A dot blot analysis showed significant denaturation of collagen I in Group 2. The histomorphology of the 2.2 mm system incision showed localized Descemet membrane detachment and endothelial cell loss. The 1.8 mm system incision showed exaggerated stromal damage after IOL insertion. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Phosphate steering by Flap Endonuclease 1 promotes 5′-flap specificity and incision to prevent genome instability

    KAUST Repository

    Tsutakawa, Susan E.

    2017-06-27

    DNA replication and repair enzyme Flap Endonuclease 1 (FEN1) is vital for genome integrity, and FEN1 mutations arise in multiple cancers. FEN1 precisely cleaves single-stranded (ss) 5\\'-flaps one nucleotide into duplex (ds) DNA. Yet, how FEN1 selects for but does not incise the ss 5\\'-flap was enigmatic. Here we combine crystallographic, biochemical and genetic analyses to show that two dsDNA binding sites set the 5\\'polarity and to reveal unexpected control of the DNA phosphodiester backbone by electrostatic interactions. Via phosphate steering\\', basic residues energetically steer an inverted ss 5\\'-flap through a gateway over FEN1\\'s active site and shift dsDNA for catalysis. Mutations of these residues cause an 18,000-fold reduction in catalytic rate in vitro and large-scale trinucleotide (GAA) repeat expansions in vivo, implying failed phosphate-steering promotes an unanticipated lagging-strand template-switch mechanism during replication. Thus, phosphate steering is an unappreciated FEN1 function that enforces 5\\'-flap specificity and catalysis, preventing genomic instability.

  18. Single site and conventional totally extraperitoneal techniques for uncomplicated inguinal hernia repair: A comparative study.

    Science.gov (United States)

    de Araújo, Felipe Brandão Corrêa; Starling, Eduardo Simão; Maricevich, Marco; Tobias-Machado, Marcos

    2014-10-01

    To demonstrate the feasibility of endoscopic extraperitoneal single site (EESS) inguinal hernia repair and compare it outcomes with the conventional totally extraperitoneal (TEP) technique. TEP inguinal hernia repair is a widely accepted alternative to conventional open technique with several perioperative advantages. Transumbilical laparoendoscopic singlesite surgery (LESS) is an emerging approach and has been reported for a number of surgical procedures with superior aesthetic results but other advantages need to be proven. Thirty-eight uncomplicated inguinal hernias were repaired by EESS approach between January 2010 and January 2011. All procedures were performed through a 25 cm infraumbilical incision using the Alexis wound retractor attached to a surgical glove and three trocars. Body mass index, age, operative time, blood loss, complications, conversion rate, analgesia requirement, hospital stay, return to normal activities and patient satisfaction with aesthetic results were analysed and compared with the last 38 matched-pair group of patients who underwent a conventional TEP inguinal hernia repair by the same surgeon. All procedures were performed successfully with no conversion. In both unilateral and bilateral EESS inguinal repairs, the mean operative time was longer than conventional TEP (55± 20 vs. 40± 15 min, P = 0.049 and 70± 15 vs. 55± 10 min, P = 0.014). Aesthetic result was superior in the EESS group (2.88± 0.43 vs. 2.79± 0.51, P = 0.042). There was no difference between the two approaches regarding blood loss, complications, hospital stay, time until returns to normal activities and analgesic requirement. EESS inguinal hernia repair is safe and effective, with superior cosmetic results in the treatment of uncomplicated inguinal hernias. Other advantages of this new technique still need to be proven.

  19. [Ladder step strategy for surgical repair of congenital concealed penis in children].

    Science.gov (United States)

    Wang, Fu-Ran; Zhong, Hong-Ji; Chen, Yi; Zhao, Jun-Feng; Li, Yan

    2016-11-01

    To assess the feasibility of the ladder step strategy in surgical repair of congenital concealed penis in children. This study included 52 children with congenital concealed penis treated in the past two years by surgical repair using the ladder step strategy, which consists of five main steps: cutting the narrow ring of the foreskin, degloving the penile skin, fixing the penile skin at the base, covering the penile shaft, and reshaping the prepuce. The perioperative data of the patients were prospectively collected and statistically described. Of the 52 patients, 20 needed remodeling of the frenulum and 27 received longitudinal incision in the penoscrotal junction to expose and deglove the penile shaft. The advanced scrotal flap technique was applied in 8 children to cover the penile shaft without tension, the pedicled foreskin flap technique employed in 11 to repair the penile skin defect, and excision of the webbed skin of the ventral penis performed in another 44 to remodel the penoscrotal angle. The operation time, blood loss, and postoperative hospital stay were 40-100 minutes, 5-30 ml, and 3-6 days, respectively. Wound bleeding and infection occurred in 1 and 5 cases, respectively. Follow-up examinations at 3 and 6 months after surgery showed that all the children had a satisfactory penile appearance except for some minor complications (2 cases of penile retraction, 2 cases of redundant ventral skin, and 1 case of iatrogenic penile curvature). The ladder step strategy for surgical repair of congenital concealed penis in children is a simple procedure with minor injury and satisfactory appearance of the penis.

  20. Clinical symptoms and DNA repair characteristics of xeroderma pigmentosum patients from Germany

    International Nuclear Information System (INIS)

    Thielmann, H.W.; Popanda, O.; Edler, L.; Jung, E.G.

    1991-01-01

    Sixty-one xeroderma pigmentosum (XP) patients living in the Federal Republic of Germany were investigated. Clinical symptoms were correlated with DNA repair parameters measured in fibroblasts grown from skin biopsies. Classification according to the international complementation groups revealed that of the 61 patients 3 belonged to group A, 26 to group C, 16 to group D, 3 to group E, and 2 to group F; 11 were of the XP variant type. A striking clinical aspect was the frequency of histogenetically different skin tumors varying from one XP complementation group to the other: squamous and basal cell carcinomas predominated in XP group C; lentigo maligna melanomas were most frequent in group D; basal cell carcinomas occurred preferentially in group E and XP variants. Three DNA repair parameters were determined for 46 fibroblast strains: colony-forming ability (D0); DNA repair synthesis (G0); and DNA-incising capacity (E0). Dose-response experiments with up to 13 dose levels were performed throughout to achieve sufficient experimental accuracy. DNA-damaging treatments included UV light, the 'UV-like' carcinogen N-acetoxy-2-acetylaminofluorene, and the alkylating carcinogens methyl methanesulfonate and N-methyl-N-nitrosourea. Comparison of clinical signs and repair data was made on the basis of D0, G0, and E0 values of both individual cell strains and weighted means of XP complementation groups. Despite considerable clinical and biochemical heterogeneity within complementation groups distinctive features emerged. In general, D0, G0, and E0 values of all XP strains investigated, including XP variants, were found to be reduced upon treatment with UV light or N-acetoxy-2-acetylaminofluorene

  1. The effect of kidney morcellation on operative time, incision complications, and postoperative analgesia after laparoscopic nephrectomy

    Directory of Open Access Journals (Sweden)

    Affonso H. Camargo

    2006-06-01

    Full Text Available INTRODUCTION: Compare the outcomes between kidney morcellation and two types of open specimen extraction incisions, several covariates need to be taken into consideration that have not yet been studied. MATERIALS AND METHODS: We retrospectively reviewed 153 consecutive patients who underwent laparoscopic nephrectomy at our institution, 107 who underwent specimen morcellation and 46 with intact specimen removal, either those with connected port sites with a muscle-cutting incision and those with a remote, muscle-splitting incision. Operative time, postoperative analgesia requirements, and incisional complications were evaluated using univariate and multivariate analysis, comparing variables such as patient age, gender, body mass index (BMI, laterality, benign versus cancerous renal conditions, estimated blood loss, specimen weight, overall complications, and length of stay. RESULTS: There was no significant difference for operative time between the 2 treatment groups (p = 0.65. Incision related complications occurred in 2 patients (4.4% from the intact specimen group but none in the morcellation group (p = 0.03. Overall narcotic requirement was lower in patients with morcellated (41 mg compared to intact specimen retrieval (66 mg on univariate (p = 0.03 and multivariate analysis (p = 0.049. Upon further stratification, however, there was no significant difference in mean narcotic requirement between the morcellation and muscle-splitting incision subgroup (p = 0.14. CONCLUSION: Morcellation does not extend operative time, and is associated with significantly less postoperative pain compared to intact specimen retrieval overall, although this is not statistically significant if a remote, muscle-splitting incision is made. Morcellation markedly reduces the risk of incisional-related complications.

  2. Three-dimensional observations of the incisive canal and the surrounding bone using cone-beam computed tomography

    International Nuclear Information System (INIS)

    Asaumi, Rieko; Kawai, Taisuke; Sato, Iwao; Yoshida, Shunji; Yosue, Takashi

    2010-01-01

    The shape of the anterior region of the maxilla is critical when planning implant treatment. The purpose of the present study was to assess the typical morphology of the incisive canal and surrounding bone. In total, 70 maxillae of Japanese dry skulls were used after being divided into dentate and edentulous groups. Cone-beam computed tomography (CBCT) images of the maxilla were acquired by using standardized methods. Using the anterior nasal spine as a reference point, the change in position was measured and analyzed statistically. Also, three-dimensional (3-D) images of the incisive canal were classified into five subsets: cylinder, groove, penetration, bifurcation at the superior portion, and bifurcation at the inferior portion. The quantity of alveolar bone in the incisor region was greatly reduced from the alveolar ridge and labial surface. Moreover, the vertical position of the incisive foramen was significantly (P<0.05) superior in the edentulous groups. Regarding the classification of maxillae by the 3-D shape of the incisive canal, many canals were cylindrical. Horizontal bone reduction from the labial side and vertical bone reduction from the alveolar crest were conspicuous; thus, the angle of the anterior alveolar bone changed after the loss of teeth. The incisive canal diameter in the edentulous group was larger than in the dentate group. The nondestructive assessment of the incisive canals and surrounding bone with CBCT showed two typical shapes for the presence or absence of the incisors. These findings indicate the importance of image diagnosis before esthetic restoration. (author)

  3. Filtering natural light at the greenhouse covering - better greenhouse climate and higher production by filtering out NIR?

    NARCIS (Netherlands)

    Hemming, S.; Kempkes, F.; Braak, van der N.; Dueck, T.A.; Marissen, A.

    2006-01-01

    Wageningen UR investigated the potentials of several NIR-filtering methods to be applied in Dutch horticulture. NIR-filtering can be done by the greenhouse covering or by internal or external moveable screens. The objective of this investigation was to quantify the effect of different NIR-filtering

  4. Potable NIR spectroscopy predicting soluble solids content of pears based on LEDs

    Energy Technology Data Exchange (ETDEWEB)

    Liu Yande; Liu Wei; Sun Xudong; Gao Rongjie; Pan Yuanyuan; Ouyang Aiguo, E-mail: jxliuyd@163.com [School of Mechatronics Engineering, East China Jiaotong University, Changbei Open and Developing District, Nanchang, 330013 (China)

    2011-01-01

    A portable near-infrared (NIR) instrument was developed for predicting soluble solids content (SSC) of pears equipped with light emitting diodes (LEDs). NIR spectra were collected on the calibration and prediction sets (145:45). Relationships between spectra and SSC were developed by multivariate linear regression (MLR), partial least squares (PLS) and artificial neural networks (ANNs) in the calibration set. The 45 unknown pears were applied to evaluate the performance of them in terms of root mean square errors of prediction (RMSEP) and correlation coefficients (r). The best result was obtained by PLS with RMSEP of 0.62{sup 0}Brix and r of 0.82. The results showed that the SSC of pears could be predicted by the portable NIR instrument.

  5. Potable NIR spectroscopy predicting soluble solids content of pears based on LEDs

    International Nuclear Information System (INIS)

    Liu Yande; Liu Wei; Sun Xudong; Gao Rongjie; Pan Yuanyuan; Ouyang Aiguo

    2011-01-01

    A portable near-infrared (NIR) instrument was developed for predicting soluble solids content (SSC) of pears equipped with light emitting diodes (LEDs). NIR spectra were collected on the calibration and prediction sets (145:45). Relationships between spectra and SSC were developed by multivariate linear regression (MLR), partial least squares (PLS) and artificial neural networks (ANNs) in the calibration set. The 45 unknown pears were applied to evaluate the performance of them in terms of root mean square errors of prediction (RMSEP) and correlation coefficients (r). The best result was obtained by PLS with RMSEP of 0.62 0 Brix and r of 0.82. The results showed that the SSC of pears could be predicted by the portable NIR instrument.

  6. Water table and overbank flow frequency changes due to suburbanization-induced channel incision, Virginia Coastal Plain, USA

    Science.gov (United States)

    Hancock, G.; Mattell, N.; Christianson, E.; Wacksman, J.

    2004-12-01

    Channel incision is a widely observed response to increased flow in urbanized watersheds, but the effects of channel lowering on riparian water tables is not well documented. In a rapidly incising suburban stream in the Virginia Coastal Plain, we hypothesize that incision has lowered floodplain water tables and decreased the overbank flow frequency, and suggest these changes impact vegetation distribution in a diverse, protected riparian habitat. The monitored stream is a tributary to the James River draining 1.3 km2, of which 15% is impervious cover. Incision has occurred largely through upstream migration of a one m high knickpoint at a rate of 1-2 m/yr, primarily during high flow events. We installed 33 wells in six floodplain transects to assess water table elevations beneath the floodplain adjacent to the incising stream. To document the impacts of incision, two transects are located 30 and 50 m upstream of the knickpoint in unincised floodplain, and the remainder are 5, 30, 70, and 100 m downstream of the knickpoint in incised floodplain. In one transect above and two below, pressure transducers attached to dataloggers provide a high-resolution record of water table response to storm events. Significant differences have been observed in the water table above and below the knickpoint. Above the knickpoint, the water table is relatively flat and is 0.2-0.4 m below the floodplain surface. Water table response to precipitation events is nearly immediate, with the water table rising to the floodplain surface in significant rainfall events. In the transect immediately downstream of the knickpoint, the water table possesses a steep gradient, rising from ~1 m below the floodplain at the stream to 0.3 m below the surface within 20 m. In the most downstream transects, the water table is relatively flat, but is one m below the floodplain surface, equivalent to the depth of incision generated by knickpoint passage. Upstream of the knickpoint, overbank flooding occurs

  7. Differences in the regulation by poly(ADP-ribose) of repair of DNA damage from alkylating agents and ultraviolet light according to cell type

    Energy Technology Data Exchange (ETDEWEB)

    Cleaver, J.E.; Bodell, W.J.; Morgan, W.F.; Zelle, B.

    1983-08-10

    Inhibition of poly(ADP-ribose) synthesis by 3-aminobenzamide in various human and hamster cells influenced the responses to DNA damage from methyl methanesulfonate, but not from ultraviolet light. After exposure to methyl methanesulfonate, 3-aminobenzamide increased the strand break frequency in all cell types studied, but only stimulated repair replication in lymphoid and HeLa cells, suggesting these are independent effects. 3-Aminobenzamide also inhibited the pathway for de novo synthesis of DNA purines, suggesting that some of its effects may be due to disturbance of precursor pathways and irrelevant to the role of poly(ADP-ribose) in repair. Previous claims that 3-aminobenzamide stimulates repair synthesis after exposure to UV light are probably artifacts, because the stimulations are only observed in lymphocytes in the presence of a high concentration of hydroxyurea that itself inhibits repair. The initial inhibition of semiconservative DNA synthesis and the excision of the major alkylation products and pyrimidine dimers were unaffected by 3-aminobenzamide. In general poly(ADP-ribose) synthesis appears to be uniquely involved in regulating the ligation stage of repair of alkylation damage but not ultraviolet damage. By regulating the ligation efficiency, poly(ADP-ribosylation) modulates the dynamic balance between incision and ligation, so as to minimize the frequency of DNA breaks. The ligation stage of repair of UV damage appears different and is not regulated by poly(ADP-ribosylation).

  8. Heterotopic ossification in abdominal incision : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Yoon Sik; Nam, Kung Sook; Hwang, Im Kyung; Kim, Heung Chul [College of Medicine, Hallym Univ., Chuncheon (Korea, Republic of)

    2001-08-01

    Heterotopic ossification in abdominal incision is a rare post-surgical sequala and a subtype of myositis ossificans traumatica. Recognition of this rare condition is important because it may be misinterpreted as a retained foreign body or incisional neoplastic recurrence. We report a case involving a 59-year-old man who presented with a palpable epigastric mass and pronounced fatigability.

  9. An image analysis system for near-infrared (NIR) fluorescence lymph imaging

    Science.gov (United States)

    Zhang, Jingdan; Zhou, Shaohua Kevin; Xiang, Xiaoyan; Rasmussen, John C.; Sevick-Muraca, Eva M.

    2011-03-01

    Quantitative analysis of lymphatic function is crucial for understanding the lymphatic system and diagnosing the associated diseases. Recently, a near-infrared (NIR) fluorescence imaging system is developed for real-time imaging lymphatic propulsion by intradermal injection of microdose of a NIR fluorophore distal to the lymphatics of interest. However, the previous analysis software3, 4 is underdeveloped, requiring extensive time and effort to analyze a NIR image sequence. In this paper, we develop a number of image processing techniques to automate the data analysis workflow, including an object tracking algorithm to stabilize the subject and remove the motion artifacts, an image representation named flow map to characterize lymphatic flow more reliably, and an automatic algorithm to compute lymph velocity and frequency of propulsion. By integrating all these techniques to a system, the analysis workflow significantly reduces the amount of required user interaction and improves the reliability of the measurement.

  10. Determination of the Mechanical Properties of Rubber by FT-NIR

    Directory of Open Access Journals (Sweden)

    Rattapol Pornprasit

    2016-01-01

    Full Text Available Mechanical tests, for example, tensile and hardness tests, are usually used to evaluate the properties of rubber materials. In this work, mechanical properties of selected rubber materials, that is, natural rubber (NR, styrene butadiene rubber (SBR, nitrile butadiene rubber (NBR, and ethylene propylene diene monomer (EPDM, were evaluated using a near infrared (NIR spectroscopy technique. Here, NR/NBR and NR/EPDM blends were first prepared. All of the samples were then scanned using a FT-NIR spectrometer and fitted with an integration sphere working in a diffused reflectance mode. The spectra were correlated with hardness and tensile properties. Partial least square (PLS calibration models were built from the spectra datasets with preprocessing techniques, that is, smoothing and second derivative. This indicated that reasonably accurate models, that is, with a coefficient of determination [R2] of the validation greater than 0.9, could be achieved for the hardness and tensile properties of rubber materials. This study demonstrated that FT-NIR analysis can be applied to determine hardness and tensile values in rubbers and rubber blends effectively.

  11. New laser design for NIR lidar applications

    Science.gov (United States)

    Vogelmann, H.; Trickl, T.; Perfahl, M.; Biggel, S.

    2018-04-01

    Recently, we quantified the very high spatio-temporal short term variability of tropospheric water vapor in a three dimensional study [1]. From a technical point of view this also depicted the general requirement of short integration times for recording water-vapor profiles with lidar. For this purpose, the only suitable technique is the differential absorption lidar (DIAL) working in the near-infrared (NIR) spectral region. The laser emission of most water vapor DIAL systems is generated by Ti:sapphire or alexandrite lasers. The water vapor absorption band at 817 nm is predominated for the use of Ti:sapphire. We present a new concept of transversely pumping in a Ti:Sapphire amplification stage as well as a compact laser design for the generation of single mode NIR pulses with two different DIAL wavelengths inside a single resonator. This laser concept allows for high output power due to repetitions rates up to 100Hz or even more. It is, because of its compactness, also suitable for mobile applications.

  12. Chemical weathering as a mechanism for the climatic control of bedrock river incision

    Science.gov (United States)

    Murphy, Brendan P.; Johnson, Joel P. L.; Gasparini, Nicole M.; Sklar, Leonard S.

    2016-04-01

    Feedbacks between climate, erosion and tectonics influence the rates of chemical weathering reactions, which can consume atmospheric CO2 and modulate global climate. However, quantitative predictions for the coupling of these feedbacks are limited because the specific mechanisms by which climate controls erosion are poorly understood. Here we show that climate-dependent chemical weathering controls the erodibility of bedrock-floored rivers across a rainfall gradient on the Big Island of Hawai‘i. Field data demonstrate that the physical strength of bedrock in streambeds varies with the degree of chemical weathering, which increases systematically with local rainfall rate. We find that incorporating the quantified relationships between local rainfall and erodibility into a commonly used river incision model is necessary to predict the rates and patterns of downcutting of these rivers. In contrast to using only precipitation-dependent river discharge to explain the climatic control of bedrock river incision, the mechanism of chemical weathering can explain strong coupling between local climate and river incision.

  13. Determination of Aluminium Content in Aluminium Hydroxide Formulation by FT-NIR Transmittance Spectroscopy

    DEFF Research Database (Denmark)

    Lai, Xuxin; Zheng, Yiwu; Søndergaard, Ib

    2007-01-01

    A method for determining the aluminium content of an aluminium hydroxide suspension using near infrared (NIR) transmittance spectroscopy has been developed. Inductively coupled plasma-atomic emission spectroscopy (ICP-AES) was used as reference method. The factors influencing the NIR analysis...... aluminium content in aluminium hydroxide suspension. (c) 2007 Elsevier Ltd. All rights reserved....

  14. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study.

    Science.gov (United States)

    Sekundo, Walter; Kunert, Kathleen S; Blum, Marcus

    2011-03-01

    This 6 month prospective multi-centre study evaluated the feasibility of performing myopic femtosecond lenticule extraction (FLEx) through a small incision using the small incision lenticule extraction (SMILE) procedure. Prospective, non-randomised clinical trial. PARTICIPANTS; Ninety-one eyes of 48 patients with myopia with and without astigmatism completed the final 6 month follow-up. The patients' mean age was 35.3 years. Their preoperative mean spherical equivalent (SE) was −4.75±1.56 D. A refractive lenticule of intrastromal corneal tissue was cut utilising a prototype of the Carl Zeiss Meditec AG VisuMax femtosecond laser system. Simultaneously two opposite small ‘pocket’ incisions were created by the laser system. Thereafter, the lenticule was manually dissected with a spatula and removed through one of incisions using modified McPherson forceps. Uncorrected visual acuity (UCVA) and best spectacle corrected visual acuity (BSCVA) after 6 months, objective and manifest refraction as well as slit-lamp examination, side effects and a questionnaire. Six months postoperatively the mean SE was −0.01 D±0.49 D. Most treated eyes (95.6%) were within ±1.0 D, and 80.2% were within ±0.5 D of intended correction. Of the eyes treated, 83.5% had an UCVA of 1.0 (20/20) or better, 53% remained unchanged, 32.3% gained one line, 3.3% gained two lines of BSCVA, 8.8% lost one line and 1.1% lost ≥2 lines of BSCVA. When answering a standardised questionnaire, 93.3% of patients were satisfied with the results obtained and would undergo the procedure again. SMILE is a promising new flapless minimally invasive refractive procedure to correct myopia.

  15. A method of posterior fossa dural incision to minimize hemorrhage from the occipital sinus: the "mosquito" method.

    Science.gov (United States)

    Lee, Hee Chang; Lee, Ji Yeoun; Ryu, Seul Ki; Lim, Jang Mi; Chong, Sangjoon; Phi, Ji Hoon; Kim, Seung-Ki; Wang, Kyu-Chang

    2016-12-01

    The posterior fossa dural opening requires the ligation of the occipital sinus to gain successful exposure. However, there could be a prominent occipital sinus which is functioning as the main drainage route and is harboring the risk of unpredictable massive hemorrhage during the dural opening. We introduce a safe method of posterior fossa dural incision to minimize hemorrhage from the occipital sinus using four curved hemostat clamps. For the dural incision at the midline part of the posterior cranial fossa, we used four curved hemostat clamps to occlude the prominent occipital sinus: one pair of clamps at the proximal part and the other pair at the distal part to occlude the occipital sinus. Dural incision was made between the two pairs of the curved hemostat clamps. By clamping of the sinus, it allows observation of possible brain swelling after occlusion of the occipital sinus as well as minimizes hemorrhage during incision of the midline dura of the posterior fossa. This method allows observation of brain swelling after occipital sinus occlusion and is an easy and safe incision of the midline dura minimizing hemorrhage in selected cases with a prominent occipital sinus.

  16. Age determination of bottled Chinese rice wine by VIS-NIR spectroscopy

    Science.gov (United States)

    Yu, Haiyan; Lin, Tao; Ying, Yibin; Pan, Xingxiang

    2006-10-01

    The feasibility of non-invasive visible and near infrared (VIS-NIR) spectroscopy for determining wine age (1, 2, 3, 4, and 5 years) of Chinese rice wine was investigated. Samples of Chinese rice wine were analyzed in 600 mL square brown glass bottles with side length of approximately 64 mm at room temperature. VIS-NIR spectra of 100 bottled Chinese rice wine samples were collected in transmission mode in the wavelength range of 350-1200 nm by a fiber spectrometer system. Discriminant models were developed based on discriminant analysis (DA) together with raw, first and second derivative spectra. The concentration of alcoholic degree, total acid, and °Brix was determined to validate the NIR results. The calibration result for raw spectra was better than that for first and second derivative spectra. The percentage of samples correctly classified for raw spectra was 98%. For 1-, 2-, and 3-year-old sample groups, the sample were all correctly classified, and for 4- and 5-year-old sample groups, the percentage of samples correctly classified was 92.9%, respectively. In validation analysis, the percentage of samples correctly classified was 100%. The results demonstrated that VIS-NIR spectroscopic technique could be used as a non-invasive, rapid and reliable method for predicting wine age of bottled Chinese rice wine.

  17. [A review on studies and applications of near infrared spectroscopy technique(NIRS) in detecting quality of hay].

    Science.gov (United States)

    Ding, Wu-Rong; Gan, You-Min; Guo, Xu-Sheng; Yang, Fu-Yu

    2009-02-01

    The quality of hay can directly affect the price of hay and also livestock productivity. Many kinds of methods have been developed for detecting the quality of hay and the method of near infrared spectroscopy (NIRS) has been widely used with consideration of its fast, effective and nondestructive characteristics during detecting process. In the present paper, the feasibility and effectiveness of application of NIRS to detecting hay quality were expounded. Meanwhile, the advance in the study of using NIRS to detect chemical compositions, extent of incursion by epiphyte, amount of toxicant excreted by endogenetic epiphyte and some minim components that can not be detected by using chemical methods were also introduced detailedly. Based on the review of the progresses in using NIRS to detect the quality of hay, it can be concluded that using NIRS to detect hay quality can avoid the disadvantages of time wasting, complication and high cost when using traditional chemical method. And for better utilization of NIRS in practice, some more studies still need to be implemented to further perfect and improve the utilization of NIRS for detecting forage quality, and more accurate modes and systematic analysis software need to be established in times to come.

  18. A New Framework for the Assessment of Cerebral Hemodynamics Regulation in Neonates Using NIRS

    NARCIS (Netherlands)

    Caicedo, Alexander; Alderliesten, Thomas; Naulaers, Gunnar; Lemmers, Petra; van Bel, Frank; Van Huffel, Sabine

    2016-01-01

    We present a new framework for the assessment of cerebral hemodynamics regulation (CHR) in neonates using near-infrared spectroscopy (NIRS). In premature infants, NIRS measurements have been used as surrogate variables for cerebral blood flow (CBF) in the assessment of cerebral autoregulation (CA).

  19. Advantages of the modified double ring areolar incision over the traditional areolar incision in multicentric breast fibroadenoma surgery.

    Science.gov (United States)

    Zhang, Mingliang; Shen, Gongjin; Zhang, Song; Cui, Zhen; Qian, Jun

    2017-09-01

    This study was conducted to investigate the clinical advantages of modified double ring areola incision (MDRAI) compared to ordinary areola incision (OAI) in multicentric breast fibroadenoma in women. Sixty cases of multicentric benign breast tumor were recruited from the First Affiliated Hospital of Bengbu Medical College from January to December 2016. The cases were divided into two groups according to surgical approach: MDRAI (n = 20) and OAI (n = 40). The operation duration, intraoperative blood loss, drainage time, and postoperative recurrence rate in the first six months were compared. The mean age and tumor locations were not statistically different between the groups (P > 0.05). However, more lesions and larger tumor diameter were found in the MDRAI group than in the OAI group, with statistical difference (P  0.05). However, the intraoperative blood loss was statistically different between the two groups (P < 0.05). All 60 cases received six months of follow-up. Eight recurrent cases were found in the OAI group, but none in the MDRAI group. The recurrence rate was significantly different (χ 2  = 4.62, P < 0.05). Compared with OAI, MDRAI offers greater advantages in the aspects of blood loss and recurrence for the treatment of breast benign tumor, especially for multicentric larger lesions. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  20. [The NIR spectra based variety discrimination for single soybean seed].

    Science.gov (United States)

    Zhu, Da-Zhou; Wang, Kun; Zhou, Guang-Hua; Hou, Rui-Feng; Wang, Cheng

    2010-12-01

    With the development of soybean producing and processing, the quality breeding becomes more and more important for soybean breeders. Traditional sampling detection methods for soybean quality need to destroy the seed, and does not satisfy the requirement of earlier generation materials sieving for breeding. Near infrared (NIR) spectroscopy has been widely used for soybean quality detection. However, all these applications were referred to mass samples, and they were not suitable for little or single seed detection in breeding procedure. In the present study, the acousto--optic tunable filter (AOTF) NIR spectroscopy was used to measure the single soybean seed. Two varieties of soybean were measured, which contained 60 KENJIANDOU43 seeds and 60 ZHONGHUANG13 seeds. The results showed that NIR spectra combined with soft independent modeling of class analogy (SIMCA) could accurately discriminate the soybean varieties. The classification accuracy for KENJIANDOU43 seeds and ZHONGHUANG13 was 100%. The spectra of single soybean seed were measured at different positions, and it showed that the seed shape has significant influence on the measurement of spectra, therefore, the key point for single seed measurement was how to accurately acquire the spectra and keep their representativeness. The spectra for soybeans with glossy surface had high repeatability, while the spectra of seeds with external defects had significant difference for several measurements. For the fast sieving of earlier generation materials in breeding, one could firstly eliminate the seeds with external defects, then apply NIR spectra for internal quality detection, and in this way the influence of seed shape and external defects could be reduced.

  1. Tuning the sensitivity of lanthanide-activated NIR nanothermometers in the biological windows.

    Science.gov (United States)

    Cortelletti, P; Skripka, A; Facciotti, C; Pedroni, M; Caputo, G; Pinna, N; Quintanilla, M; Benayas, A; Vetrone, F; Speghini, A

    2018-02-01

    Lanthanide-activated SrF 2 nanoparticles with a multishell architecture were investigated as optical thermometers in the biological windows. A ratiometric approach based on the relative changes in the intensities of different lanthanide (Nd 3+ and Yb 3+ ) NIR emissions was applied to investigate the thermometric properties of the nanoparticles. It was found that an appropriate doping with Er 3+ ions can increase the thermometric properties of the Nd 3+ -Yb 3+ coupled systems. In addition, a core containing Yb 3+ and Tm 3+ can generate light in the visible and UV regions upon near-infrared (NIR) laser excitation at 980 nm. The multishell structure combined with the rational choice of dopants proves to be particularly important to control and enhance the performance of nanoparticles as NIR nanothermometers.

  2. Seismic evidence of glacial-age river incision into the Tahaa barrier reef, French Polynesia

    Science.gov (United States)

    Toomey, Michael; Woodruff, Jonathan D.; Ashton, Andrew D.; Perron, J. Taylor

    2016-01-01

    Rivers have long been recognized for their ability to shape reef-bound volcanic islands. On the time-scale of glacial–interglacial sea-level cycles, fluvial incision of exposed barrier reef lagoons may compete with constructional coral growth to shape the coastal geomorphology of ocean islands. However, overprinting of Pleistocene landscapes by Holocene erosion or sedimentation has largely obscured the role lowstand river incision may have played in developing the deep lagoons typical of modern barrier reefs. Here we use high-resolution seismic imagery and core stratigraphy to examine how erosion and/or deposition by upland drainage networks has shaped coastal morphology on Tahaa, a barrier reef-bound island located along the Society Islands hotspot chain in French Polynesia. At Tahaa, we find that many channels, incised into the lagoon floor during Pleistocene sea-level lowstands, are located near the mouths of upstream terrestrial drainages. Steeper antecedent topography appears to have enhanced lowstand fluvial erosion along Tahaa's southwestern coast and maintained a deep pass. During highstands, upland drainages appear to contribute little sediment to refilling accommodation space in the lagoon. Rather, the flushing of fine carbonate sediment out of incised fluvial channels by storms and currents appears to have limited lagoonal infilling and further reinforced development of deep barrier reef lagoons during periods of highstand submersion.

  3. The Problem of the Pannus: Physician Preference Survey and a Review of the Literature on Cesarean Skin Incision in Morbidly Obese Women.

    Science.gov (United States)

    Smid, Marcela C; Smiley, Sarah G; Schulkin, Jay; Stamilio, David M; Edwards, Rodney K; Stuebe, Alison M

    2016-04-01

    This study aims to determine preferences of a nationally representative sample of obstetrician/gynecologists (OB/GYNs) regarding cesarean delivery (CD) incision practices for women with morbid obesity (body mass index ≥ 40 kg/m(2)). We conducted an online survey using the American College of Obstetricians and Gynecologists database. We compared physician demographics, practice characteristics, and CD incision type preference. After exclusion of ineligible participants, 247 OB/GYNs completed the survey (42% response rate). In nonemergency CD of morbidly obese women, 84% of physicians preferred a Pfannenstiel skin incision (67% preferring taping the pannus; 17% without taping the pannus). In emergency CD, 66% preferred a Pfannenstiel incision (46% without taping the pannus; 20% with taping the pannus) and 20% a vertical incision. For both emergency and nonemergency CD, there was no difference in incision type preferences by provider years in practice, practice scope, or number of CD performed each year. Given the preference of a Pfannenstiel incision with taping the pannus during CD of morbidly obese women, further investigation is needed to assess the risks and benefits of this incision and the practice of elevating the pannus. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. FT-NIR: A Tool for Process Monitoring and More.

    Science.gov (United States)

    Martoccia, Domenico; Lutz, Holger; Cohen, Yvan; Jerphagnon, Thomas; Jenelten, Urban

    2018-03-30

    With ever-increasing pressure to optimize product quality, to reduce cost and to safely increase production output from existing assets, all combined with regular changes in terms of feedstock and operational targets, process monitoring with traditional instruments reaches its limits. One promising answer to these challenges is in-line, real time process analysis with spectroscopic instruments, and above all Fourier-Transform Near Infrared spectroscopy (FT-NIR). Its potential to afford decreased batch cycle times, higher yields, reduced rework and minimized batch variance is presented and application examples in the field of fine chemicals are given. We demonstrate that FT-NIR can be an efficient tool for improved process monitoring and optimization, effective process design and advanced process control.

  5. Impact of selective pituitary gland incision or resection on hormonal function after adenoma or cyst resection.

    Science.gov (United States)

    Barkhoudarian, Garni; Cutler, Aaron R; Yost, Sam; Lobo, Bjorn; Eisenberg, Amalia; Kelly, Daniel F

    2015-12-01

    With the resection of pituitary lesions, the anterior pituitary gland often obstructs transsphenoidal access to the lesion. In such cases, a gland incision and/or partial gland resection may be required to obtain adequate exposure. We investigate this technique and determine the associated risk of post-operative hypopituitarism. All patients who underwent surgical resection of a pituitary adenoma or Rathke cleft cyst (RCC) between July 2007 and January 2013 were analyzed for pre- and post-operative hormone function. The cohort of patients with gland incision/resection were compared to a case-matched control cohort of pituitary surgery patients. Total hypophysectomy patients were excluded from outcome analysis. Of 372 operations over this period, an anterior pituitary gland incision or partial gland resection was performed in 79 cases (21.2 %). These include 53 gland incisions, 12 partial hemi-hypophysectomies and 14 resections of thinned/attenuated anterior gland. Diagnoses included 64 adenomas and 15 RCCs. New permanent hypopituitarism occurred in three patients (3.8 %), including permanent DI (3) and growth hormone deficiency (1). There was no significant difference in the rate of worsening gland dysfunction nor gain of function. Compared to a control cohort, there was a significantly lower incidence of transient DI (1.25 vs. 11.1 %, p = 0.009) but no significant difference in permanent DI (3.8 vs. 4.0 %) in the gland incision group. Selective gland incisions and gland resections were performed in over 20 % of our cases. This technique appears to minimize traction on compressed normal pituitary gland during removal of large lesions and facilitates better visualization and removal of cysts, microadenomas and macroadenomas.

  6. Incision of the heart during meat inspection of fattening pigs - A risk-profile approach.

    Science.gov (United States)

    Leps, J; Fries, R

    2009-01-01

    Meat inspection in the EU is based on Regulation (EC) 854/2004. Accordingly a risk based meat inspection should be implemented. In this paper, the incision of the heart in pig meat inspection is discussed with respect to efficacy. The incision especially can reveal the presence of endocarditis. Here, Erysipelothrixrhusiopathiae (E. rhusiopathiae) and/or Streptococcussuis (S. suis) are of particular concern. Both agents are regarded to be zoonotic agents. There is some evidence for infection of humans via an alimentary pathway. Hence, the occurrence of E. rhusiopathiae and S. suis is a concern of public health (PH) as well as veterinary public health (VPH). However, other measures, including on-farm disease prevention and diagnosis, seem to be more important for food safety. It is concluded that the incision and inspection of the heart is not justifiable with respect to PH aspects.

  7. The application of near infrared spectroscopy (NIR technique for

    Directory of Open Access Journals (Sweden)

    Sandor Barabassy

    2001-06-01

    Full Text Available The production of cow’s milk in Hungary fluctuates by 15-20 % annualy. Surplus milk is dried into powder and can also be converted to modified milk powders using techniques such as ultra filtration. From approximetely 20.000 tonnes, of all milk powder types, 3.000 tonnes, is converted using ultra filtration technology. Multivariable near infrared (NIR calibration was performed on powder mixtures of whole milk, skimmed milk, whey, retenate (protein concentrate and lactose for rapid fat, protein, lactose, water and ash content determination. More than 150 samples were prepared and measured in two NIRS labs (Scottish Agriculture College – SAC – Aberdeen and University of Horticulture and Food Science - UHFS – Budapest. The results obtained from the same samples were compared. The aims of the study were: 1. Rapid quantitative and qualitative determination of mixtures of milk powder products using NIR technique. 2. Comparison of the results achieved in Aberdeen (SAC and Budapest (UHFS institutes. The mass per cent varied between 0.0-2.8% for fat, 0.0-80% for protein, 6.6-100 % for lactose, 0.0-5.0 % for water and 0.0-8.0 % for ash. High correlation coefficients (0.97-0.99 were found for all five components.

  8. Hybrid EEG-fNIRS-Based Eight-Command Decoding for BCI: Application to Quadcopter Control.

    Science.gov (United States)

    Khan, Muhammad Jawad; Hong, Keum-Shik

    2017-01-01

    In this paper, a hybrid electroencephalography-functional near-infrared spectroscopy (EEG-fNIRS) scheme to decode eight active brain commands from the frontal brain region for brain-computer interface is presented. A total of eight commands are decoded by fNIRS, as positioned on the prefrontal cortex, and by EEG, around the frontal, parietal, and visual cortices. Mental arithmetic, mental counting, mental rotation, and word formation tasks are decoded with fNIRS, in which the selected features for classification and command generation are the peak, minimum, and mean ΔHbO values within a 2-s moving window. In the case of EEG, two eyeblinks, three eyeblinks, and eye movement in the up/down and left/right directions are used for four-command generation. The features in this case are the number of peaks and the mean of the EEG signal during 1 s window. We tested the generated commands on a quadcopter in an open space. An average accuracy of 75.6% was achieved with fNIRS for four-command decoding and 86% with EEG for another four-command decoding. The testing results show the possibility of controlling a quadcopter online and in real-time using eight commands from the prefrontal and frontal cortices via the proposed hybrid EEG-fNIRS interface.

  9. Closure of Myelomeningocele Defects Using a Limberg Flap or Direct Repair

    Directory of Open Access Journals (Sweden)

    Jung-Hwan Shim

    2016-01-01

    Full Text Available BackgroundThe global prevalence of myelomeningocele has been reported to be 0.8–1 per 1,000 live births. Early closure of the defect is considered to be the standard of care. Various surgical methods have been reported, such as primary skin closure, local skin flaps, musculocutaneous flaps, and skin grafts. The aim of this study was to describe the clinical characteristics of myelomeningocele defects and present the surgical outcomes of recent cases of myelomeningocele at our institution.MethodsPatients who underwent surgical closure of myelomeningocele at our institution from January 2004 to December 2013 were included in this study. A retrospective chart review of their medical records was performed, and comorbidities, defect size, location, surgical procedures, complications, and the final results were analyzed.ResultsA total of 14 patients underwent surgical closure for myelomeningocele defects. Twelve cases were closed with direct skin repair, while two cases required local skin flaps to cover the skin defects. Three cases of infection occurred, requiring incision and either drainage or removal of allogenic materials. One case of partial flap necrosis occurred, requiring secondary revision using a rotational flap and a full-thickness skin graft. Despite these complications, all wounds eventually healed completely.ConclusionsMost myelomeningocele defects can be managed by direct skin repair alone. In cases of large defects, in which direct repair is not possible, local flaps may be used to cover the defect. Complications such as wound dehiscence and partial flap necrosis occurred in this study; however, all such complications were successfully managed with simple ancillary procedures.

  10. New NIR Absorbing DPP-based Polymer for Thick Organic Solar Cells

    KAUST Repository

    Oklem, Gulce

    2018-02-05

    infrared region (NIR) for better photon harvesting in organic solar cells. It has been shown that copolymers compromising diketopyrrolopyrrole based acceptors and simple donors (thiophene or furan) achieve absorption maximum around 800 nm. In this study, the selenophene based donor units coupled with diketopyrrolopyrrole acceptor unit based polymer (PFDPPSe) was synthesized with an absorption maximum at 830 nm and absorption onset of 930 nm. The optimized organic solar cells with PFDDPSe: PC71BM active layer blends of 210 nm showed maximum PCE of 6.16 % (ave. 6.02 %) via solvent additive engineering with inverted device structure. Charge transport, recombination loss mechanism, and morphology are systematically studied. These results demonstrate that highly efficient NIR polymer can be achieved by the introduction of selenophene and a suitable solvent additive process suitable for NIR organic solar cells. PFDPPSe is also one of the rare examples of a polymer with a PCE over 6% that does not contain any thiophene-based unit in its backbone.

  11. No-Drain Single Incision Liposuction Pull-Through Technique for Gynecomastia.

    Science.gov (United States)

    Khalil, Ashraf A; Ibrahim, Amr; Afifi, Ahmed M

    2017-04-01

    Several different methods have been proposed for treatment of gynecomastia, depending on the amount of breast enlargement and skin redundancy. The liposuction pull-through technique has been proposed as an efficacious treatment for many gynecomastia cases. This work aims to study the outcome of this technique when applied as an outpatient procedure, without the use of drains and through a single incision. Fifty-two patients with bilateral gynecomastia without significant skin excess were included in this study. The liposuction pull-through technique was performed through a single incision just above the inframammary fold and without the use of drains. Patients were followed up for 6 months. The proposed technique was able to treat the gynecomastia in all patients, with a revision rate of 1.9% to remove residual glandular tissues. There were no seromas, hematomas, nipple distortion, permanent affection of nipple sensation or wound healing problems. The liposuction pull-through technique is an effective treatment for gynecomastia without significant skin redundancy. It combines the benefits of the direct excision of glandular tissues, with the minimally invasive nature of liposuction. Performing the procedure through a single incision without the use of drains and without general anesthesia is a safe alternative. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors http://www.springer.com/00266 .

  12. Gynecomastia: glandular-liposculpture through a single transaxillary one hole incision.

    Science.gov (United States)

    Lee, Yung Ki; Lee, Jun Hee; Kang, Sang Yoon

    2018-04-01

    Gynecomastia is characterized by the benign proliferation of breast tissue in men. Herein, we present a new method for the treatment of gynecomastia, using ultrasound-assisted liposuction with both conventional and reverse-cutting edge tip cannulas in combination with a pull-through lipectomy technique with pituitary forceps through a single transaxillary incision. Thirty patients were treated with this technique at the author's institution from January 2010 to January 2015. Ten patients were treated with conventional surgical excision of the glandular/fibrous breast tissue combined with liposuction through a periareolar incision before January 2010. Medical records, clinical photographs and linear analog scale scores were analyzed to compare the surgical results and complications. The patients were required to rate their cosmetic outcomes based on the linear analog scale with which they rated their own surgical results; the mean overall average score indicated a good or high level of satisfaction. There were no incidences of skin necrosis, hematoma, infection and scar contracture; however, one case each of seroma and nipple inversion did occur. Operative time was reduced overall using the new technique since it is relatively simple and straightforward. According to the evaluation by the four independent researchers, the patients treated with this new technique showed statistically significant improvements in scar and nipple-areolar complex (NAC) deformity compared to those who were treated using the conventional method. Glandular liposculpture through a single transaxillary incision is an efficient and safe technique that can provide aesthetically satisfying and consistent results.

  13. Triple pelvic osteotomy in Legg-Calve-Perthes disease using a single anterolateral incision: a 4-year review.

    LENUS (Irish Health Repository)

    Conroy, Eimear

    2010-07-01

    Femoral head incongruency at skeletal maturity is associated with the development of osteoarthritis in early adulthood. Containment of the femoral head provides a larger surface area for remodelling of the collapsed femoral head and the development of spherical congruency. Triple pelvic osteotomy has a role to play in Legg-Calve-Perthes\\' disease by improving femoral head containment and preventing subluxation. This is traditionally a two-incision approach with significant associated morbidity. In our unit we perform triple osteotomies through a single anterolateral incision. To retrospectively review the clinical and radiographic outcome of children who had triple osteotomies performed through a single incision over a 4-year period. In our unit from 2003 to 2006 we performed eight triple osteotomies through a single incision in children aged between 6 and 12 years with Legg-Calve-Perthes\\' disease. The procedure was performed through a single anterolateral incision made beneath the middle of the iliac crest and carried forward according to Salter\\'s osteotomy. Image intensification was used to confirm iliac, pubic and ischial cuts. After performing a standard Salter\\'s osteotomy the acetabular fragment was free to rotate anteriorly and laterally. None of the children were casted and all were allowed immediate mobilization nonweight bearing with crutches for 6 weeks. Clinical results and hip function were measured preoperatively and postoperatively using the modified Harris hip score. The average length of hospital stay was 4.7 days. None of the children had a nonunion. The centre edge angle of Wiberg was measured on all preoperative and postoperative anteroposterior pelvic radiographs. In all our patients there was an improvement in the centre edge angle of Wiberg and in the modified Harris hip score. The preoperative modified Harris hip scores ranged from 38 to 60 and postoperatively ranged from 77 to 92. The preoperative centre edge angle of Wiberg ranged

  14. Single seed NIR as a fast method to predict germination ability in Pak Choi

    DEFF Research Database (Denmark)

    Gislum, René; Deleuran, Lise Christina; Olesen, Merete Halkjær

    2012-01-01

    Single seed NIR has further been tested to determine the applicability for prediction of seed viability in radish (Raphanus sativus L.) seeds and spinach (Spinacia oleracea L.) seeds. The studies show the possibility of using NIR spectroscopy in a seed separating process in the future, provided...

  15. Rapid analysis of hay attributes using NIRS. Final report, Task II alfalfa supply system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-24

    This final report provides technical information on the development of a near infrared reflectance spectroscopy (NIRS) system for the analysis of alfalfa hay. The purpose of the system is to provide consistent quality for processing alfalfa stems for fuel and alfalfa leaf meal products for livestock feed. Project tasks were to: (1) develop an NIRS driven analytical system for analysis of alfalfa hay and processed alfalfa products; (2) assist in hiring a qualified NIRS technician and recommend changes in testing equipment necessary to provide accurate analysis; (3) calibrate the NIRS instrument for accurate analyses; and (4) develop prototype equipment and sampling procedures as a first step towards development of a totally automated sampling system that would rapidly sample and record incoming feedstock and outbound product. An accurate hay testing program was developed, along with calibration equations for analyzing alfalfa hay and sun-cured alfalfa pellets. A preliminary leaf steam calibration protocol was also developed. 7 refs., 11 figs., 10 tabs.

  16. Measurement of internal quality of watermelon by Vis/NIR diffuse transmittance technique

    Science.gov (United States)

    Tian, Haiqing; Xu, Huirong; Ying, Yibin; Lu, Huishan; Yu, Haiyan

    2006-10-01

    Watermelon is a popular fruit in the world. Soluble solids content (SSC) is major characteristic used for assessing watermelon internal quality. This study was about a method for nondestructive internal quality detection of watermelons by means of visible/Near Infrared (Vis/NIR) diffuse transmittance technique. Vis/NIR transmittance spectra of intact watermelons were acquired using a low-cost commercially available spectrometer when the watermelon was in motion (1.4m/s) and in static state. Spectra data were analyzed by partial least squares (PLS) method. The influences of different data preprocessing and spectra treatments were also investigated. Performance of different models was assessed in terms of root mean square errors of calibration (RMSEC), root mean square errors of prediction (RMSEP) and correlation coefficient (r) between the predicted and measured parameter values. Results showed that spectra data preprocessing influenced the performance of the calibration models and the PLS method can provide good results. The nondestructive Vis/NIR measurements provided good estimates of SSC index of watermelon both in motion and in static state, and the predicted values were highly correlated with destructively measured values. The results indicated the feasibility of Vis/NIR diffuse transmittance spectral analysis for predicting watermelon internal quality in a nondestructive way.

  17. Two Late Pleistocene climate-driven incision/aggradation rhythms in the middle Dnieper River basin, west-central Russian Plain

    Science.gov (United States)

    Panin, Andrei; Adamiec, Grzegorz; Buylaert, Jan-Pieter; Matlakhova, Ekaterina; Moska, Piotr; Novenko, Elena

    2017-06-01

    In valleys of the River Seim and its tributaries in the middle Dnieper basin (west-central Russian Plain), two low terraces (T1, 10-16 m, and T0, 5-7 m above the river) and a floodplain (2-4 m) with characteristic large and small palaeochannels exist. A range of field and laboratory techniques was applied and ∼30 new numerical ages (OSL and 14C dates) were obtained to establish a chronology of incision and aggradation events that resulted in the current valley morphology. Two full incision/aggradation rhythms and one additional aggradation phase from the previous rhythm were recognized in the Late Pleistocene - Holocene climate cycle. The following events were detected. (1) Late MIS 5 - early MIS 4: aggradation of Terrace T1 following the deep incision at the end of MIS 6. (2) Late MIS 4 (40-30 ka): incision into Terrace T1 below the present-day river, formation of the main scarp in the bottom of the valley between Terrace T1 and Terrace T0/Floodplain levels. (3) MIS 2: aggradation of Terrace T0, lateral migrations of a shallow braided channel located few meters above the present-day river since ∼25 ka through the LGM. (4) 18-13 ka: incision into Terrace T0 below the modern river. Multiple-thread channels concentrated in a single flow that at some places formed large meanders. In the period 15-13 ka, high floods that rose above the present-day floods left large levees and overbank loams on Terrace T0. (5) Younger Dryas - Holocene transition: aggradation up to the modern channel level, transformation of large Late Glacial to small Holocene meanders. The established incision/aggradation rhythms are believed to be manifested over the Central Russian Plain outside the influence of ice sheets in the north and base level changes in the south. The two-phase deepening of the valley occurred in the last quarter of the last glacial epoch but can not be attributed directly to the glacial-interglacial transition. Both the detected incision events correspond to relatively

  18. In vivo architectural analysis of 3.2 mm clear corneal incisions for phacoemulsification using optical coherence tomography.

    Science.gov (United States)

    Torres, Luis F; Saez-Espinola, Fidelia; Colina, Juner M; Retchkiman, Myriam; Patel, Milan R; Agurto, Ricardo; Garcia, Gerardo; Diaz, Jose L; Huang, David; Schanzlin, David J; Chayet, Arturo S

    2006-11-01

    To analyze in vivo the architecture of clear corneal incisions (CCIs) for phacoemulsification using optical coherence tomography (OCT). Anterior Segment Department, Asociacion Para Evitar la Ceguera en Mexico, Hospital Dr Luis Sanchez Bulnes, Mexico. A prospective masked study analyzed 20 unsutured CCIs placed superiorly and created in a uniplanar fashion with a 3.2 mm slit-angled metal keratome. All wounds were evaluated with a retinal OCT model 1, 3, and 30 days postoperatively. Intraocular pressure (IOP) and incision leakage were checked. The architecture was described according to the angle of incidence, apposition of the epithelial and endothelial margins, and wound sealing. No leakage was detected. The angle varied from 33 to 85 degrees; angles greater than 75 degrees were done by a surgeon in training. Wound apposition at the epithelial margin was achieved in all cases. In contrast, imperfect apposition of the endothelial margin was seen in 45% of incisions on day 1 and in 15% on day 30. Incomplete sealing of the wound was seen by OCT in 25% of cases at 24 hours and persisted in 10% of all cases at 1 month. This gaping occurred on the endothelial side and never translated to the epithelial margin. No statistical correlation was found between gaping and the angle of the incision, IOP variations, or surgeon experience. Although in vivo CCIs caused minor anatomic imperfections, they were clinically stable independent of incision angle, IOP variation, and surgeon experience. Incision stability may be related to careful wound construction, epithelial viability, stromal edema, and efficient endothelial pumping.

  19. Quantitative analysis of the relationship between maxillary incisors and the incisive canal by cone-beam computed tomography in an adult Japanese population

    Directory of Open Access Journals (Sweden)

    Tomonari Matsumura

    2017-08-01

    Full Text Available Abstract Background In setting goals for orthodontic treatment, determining the morphologies of the alveolar bone and maxillary incisor root is important for avoiding root resorption, dehiscence, and fenestration. This study aimed to analyze the configurational relationships among maxillary incisors, the alveolar border, and the incisive canal by cone-beam computed tomography (CBCT. Methods Cone-beam CT images of 93 orthodontic patients were evaluated for length of the incisive canal (L; angles between the palatal plane and the maxillary alveolar border (θ1, the incisive canal (θ2, and maxillary incisor (θ3; distance from the left maxillary incisor to the incisive canal (D; and cross-sectional areas of the incisive canal (CSAs at three vertical levels. Comparison of variables between male and female patients was performed with the two-sample t test. Correlations between parameters were examined by Pearson’s correlation analysis and Bonferroni correction for multiple comparisons. Results Male patients exhibited significantly greater values of L than female patients. There were significant positive correlations between θ1 and θ2, θ2 and θ3, and θ3 and θ1. While the value of D was the lowest at the oral opening, that of the cross-sectional area of the incisive canal (CSA was the greatest at the incisal root apex. Conclusions This study demonstrated that the incisive canal had large inter-individual variability, and the proximity between the incisive canal and the incisal root could not be precisely predicted by the conventional cephalograms. Therefore, pre-treatment CBCT examination should be recommended when a large amount of maxillary anterior retraction and/or intrusion is planned in orthodontic diagnosis.

  20. Evaluation of Pleasure-Displeasure Induced by Use of Lipsticks with Near-Infrared Spectroscopy (NIRS): Usefulness of 2-Channel NIRS in Neuromarketing.

    Science.gov (United States)

    Tanida, M; Okabe, M; Tagai, K; Sakatani, K

    2017-01-01

    In order to examine whether near-infrared spectroscopy (NIRS) would be a useful neuromarketing tool, we employed NIRS to evaluate the difference of pleasure-displeasure in women, induced by the use of different types of lipsticks. The subjects used lipsticks A and B; A is softer than B. Concentration changes of oxy-Hb were measured in the bilateral prefrontal cortex (PFC) during use of lipsticks A and B. We evaluated the right and left dominancy of PFC activity by calculating the Laterality Index (LI) (LI = leftΔoxy-Hb - rightΔoxy-Hb); positive LI indicates left-dominant activity while negative LI indicate right-dominant activity. We found a significant interaction between the use of lipsticks A and B, using a two-way factorial analysis of variance [F(1,13) = 9.63, p neuromarketing tool, since it allows objective assessment of pleasure-unpleasure.

  1. Cervical and incisal marginal discrepancy in ceramic laminate veneering materials: A SEM analysis

    Directory of Open Access Journals (Sweden)

    Hemalatha Ranganathan

    2017-01-01

    Full Text Available Context: Marginal discrepancy influenced by the choice of processing material used for the ceramic laminate veneers needs to be explored further for better clinical application. Aims: This study aimed to evaluate the amount of cervical and incisal marginal discrepancy associated with different ceramic laminate veneering materials. Settings and Design: This was an experimental, single-blinded, in vitro trial. Subjects and Methods: Ten central incisors were prepared for laminate veneers with 2 mm uniform reduction and heavy chamfer finish line. Ceramic laminate veneers fabricated over the prepared teeth using four different processing materials were categorized into four groups as Group I - aluminous porcelain veneers, Group II - lithium disilicate ceramic veneers, Group III - lithium disilicate-leucite-based veneers, Group IV - zirconia-based ceramic veneers. The cervical and incisal marginal discrepancy was measured using a scanning electron microscope. Statistical Analysis Used: ANOVA and post hoc Tukey honest significant difference (HSD tests were used for statistical analysis. Results: The cervical and incisal marginal discrepancy for four groups was Group I - 114.6 ± 4.3 μm, 132.5 ± 6.5 μm, Group II - 86.1 ± 6.3 μm, 105.4 ± 5.3 μm, Group III - 71.4 ± 4.4 μm, 91.3 ± 4.7 μm, and Group IV - 123.1 ± 4.1 μm, 142.0 ± 5.4 μm. ANOVA and post hoc Tukey HSD tests observed a statistically significant difference between the four test specimens with regard to cervical marginal discrepancy. The cervical and incisal marginal discrepancy scored F = 243.408, P < 0.001 and F = 180.844, P < 0.001, respectively. Conclusion: This study concluded veneers fabricated using leucite reinforced lithium disilicate exhibited the least marginal discrepancy followed by lithium disilicate ceramic, aluminous porcelain, and zirconia-based ceramics. The marginal discrepancy was more in the incisal region than in the cervical region in all the groups.

  2. Real-time near IR (1310 nm) imaging of CO2 laser ablation of enamel.

    Science.gov (United States)

    Darling, Cynthia L; Fried, Daniel

    2008-02-18

    The high-transparency of dental enamel in the near-IR (NIR) can be exploited for real-time imaging of ablation crater formation during drilling with lasers. NIR images were acquired with an InGaAs focal plane array and a NIR zoom microscope during drilling incisions in human enamel samples with a lambda=9.3-microm CO(2) laser operating at repetition rates of 50-300-Hz with and without a water spray. Crack formation, dehydration and thermal changes were observed during ablation. These initial images demonstrate the potential of NIR imaging to monitor laser-ablation events in real-time to provide information about the mechanism of ablation and to evaluate the potential for peripheral thermal and mechanical damage.

  3. Origin of broad NIR photoluminescence in bismuthate glass and Bi-doped glasses at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Mingying; Zollfrank, Cordt; Wondraczek, Lothar [Lehrstuhl fuer Glas und Keramik, WW3, Friedrich Alexander Universitaet Erlangen-Nuernberg, Martensstrasse 5, D-91058 Erlangen (Germany)], E-mail: mingying.peng@ww.uni-erlangen.de, E-mail: lothar.wondraczek@ww.uni-erlangen.de

    2009-07-15

    Bi-doped glasses with broadband photoluminescence in the near-infrared (NIR) spectral range are presently receiving significant consideration for potential applications in telecommunications, widely tunable fiber lasers and spectral converters. However, the origin of NIR emission remains disputed. Here, we report on NIR absorption and emission properties of bismuthate glass and their dependence on the melting temperature. Results clarify that NIR emission occurs from the same centers as it does in Bi-doped glasses. The dependence of absorption and NIR emission of bismuthate glasses on the melting temperature is interpreted as thermal dissociation of Bi{sub 2}O{sub 3} into elementary Bi. Darkening of bismuthate glass melted at 1300 deg. C is due to the agglomeration of Bi atoms. The presence of Bi nanoparticles is confirmed by transmission electron microscopy, high-resolution energy dispersive x-ray spectroscopy and element distribution mapping. By adding antimony oxide as an oxidation agent to the glass, NIR emission centers can be eliminated and Bi{sup 3+} is formed. By comparing with atomic spectral data, absorption bands at {approx}320 , {approx}500 , 700 , 800 and 1000 nm observed in Bi-doped glasses are assigned to Bi{sup 0} transitions {sup 4}S{sub 3/2}{yields}{sup 2}P{sub 3/2}, {sup 4}S{sub 3/2}{yields}{sup 2}P{sub 1/2}, {sup 4}S{sub 3/2}{yields}{sup 2}D{sub 5/2}, {sup 4}S{sub 3/2}{yields}{sup 2}D{sub 3/2}(2) and {sup 4}S{sub 3/2}{yields}{sup 2}D{sub 3/2}(1), respectively, and broadband NIR emission is assigned to the transition {sup 2}D{sub 3/2}(1){yields}{sup 4}S{sub 3/2}.

  4. Relationship between peri-incisional dysesthesia and the vertical and oblique incisions on the hamstrings harvest in anterior cruciate ligament reconstruction

    Directory of Open Access Journals (Sweden)

    Marcos Laube Leite

    Full Text Available ABSTRACT OBJECTIVE: To compare the incidence of peri-incisional dysesthesia according to the skin incision technique for hamstring tendon graft harvest in anterior cruciate ligament reconstruction. METHODS: Thirty-three patients with ACL rupture were separated in two groups: group 1, with 19 patients submitted to the oblique skin incision to access the hamstrings and group 2-14 patients operated by vertical skin incision technique. The selected patients were assessed after surgery. Demographic data and prevalence of dysesthesia was measured by digital pressure around the skin incision and classified according to the Highet scale. RESULTS: The total rate of dysesthesia was 42% (14 patients. Five patients (26% on the oblique incision group reported dysesthesia symptoms. On the group submitted to the vertical incision technique, the involvement was 64% (nine patients. On the 33 knees evaluated, the superior lateral area was the most affected skin region, while the superior medial and inferior medial regions were affected in only one patient (7.1%. No statistical differences between both groups were observed regarding patients' weight, age, and height¸ as well as skin incision length. CONCLUSION: Patients who underwent reconstruction of the anterior cruciate ligament using the oblique access technique had five times lower incidence of peri-incisional dysesthesia when compared with those in whom the vertical access technique was used.

  5. [Is there a relation between mammaplasties incisions and the final shape of the breast?].

    Science.gov (United States)

    Moufarrège, R; Dionyssopoulos, A; Aymeric, A; Sauvageau, J

    2010-04-01

    The results of reduction mammoplasty and mastopexy demonstrate a great variety of shapes derived from the particularities inherent to each technique. More precisely, it has become apparent to us that the usage of an abnormally long vertical scar leads to a suboptimal final shape of the breast due to the excessive projection compared to its height. Although our clientele continually asks to minimize scars, we have noticed a resurgence in the literature of vertical incision mammoplasty techniques albeit with a scar of an excessive length. The multitude of publications leads to an evident and consistent conclusion: breasts reconstructed with an overly long vertical incision all suffer the same deformity characterized by a banana or squash-shaped breast. We studied the totality of publications on vertical incision technique mammoplasty from the last 15 years and realised they all presented the same problem: an abnormally low height/projection ratio. These numbers have been confronted by the golden ratio established by the first author (2005) [1]. The breast's golden ratio developed by Moufarrège is optimal at a number close to, or superior to 2. Results between 2 and 1.5 are acceptable. All height/projection ratios inferior to 1.5 correspond to suboptimal breast shapes. Furthermore, the totality of results in the vertical scar mammoplasty technique which displayed unsatisfying results had a height/projection ratio inferior to 1.5. Those who promote the vertical incision have the greatest drive to encourage other plastic surgeons to abandon the traditional mutilating boat anchor scar. Nevertheless, they should always remember the deforming effect caused by exaggerated vertical incisions which may be avoided by transforming it into an inverted T with short horizontal branches, a small price to pay to obtain a superior aesthetic result. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  6. High-power diode laser in the circumvestibular incision for Le Fort I osteotomy in orthognathic surgery: a prospective case series study.

    Science.gov (United States)

    Jaeger, Filipe; Chiavaioli, Gustavo Marques; de Toledo, Guilherme Lacerda; Freire-Maia, Belini; Amaral, Marcio Bruno Figueiredo; Mesquita, Ricardo Alves

    2018-01-01

    The incisions during orthognathic surgery are classically performed with conventional scalpel or electrocautery. Considering that the high-power diode laser surgery may provide advantages when compared to conventional incision techniques, the current study aimed to present a prospective case series of patients submitted to circumvestibular incision for Le Fort I osteotomy. Ten patients with dentofacial deformities who underwent to rapid assisted maxillary expansion or bimaxillary orthognathic surgery were enrolled in the study. All incisions were performed by a single surgeon using an 808-nm diode laser, with an optical fiber of 600 μm, at a power of 2.5 W, in a continuous-wave mode. The performance of the incision was evaluated by incision velocity, bleeding, edema, secondary infection, clinical healing, and pain. The velocity of the incision ranged from 0.10 to 0.20 mm/s (mean 0.13 ± 0.03 mm/s). Considering bleeding during the soft tissue incision, all surgeries were classified as absent bleeding. All patients presented a clinical healing of the surgical wound in a period that range from 3 to 5 weeks and experienced swelling during the follow-up period. On average, approximately 50% of the swelling had resolved after the third postoperative week, and 28.8% of swelling remained after 2 months after the surgery. The pain decreased after 2 and 3 days, and 90.0% of the patients reported no pain after 7 postoperative days. High-power diode laser is effective and safety during circumvestibular incisions for Le Fort I osteotomy in orthognathic surgery decreasing bleeding, surgery time, pain, and edema after orthognathic surgery.

  7. HARDERSEN IRTF ASTEROID NIR REFLECTANCE SPECTRA V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset includes average near-infrared (NIR) reflectance spectra for 68 main-belt asteroids that were observed at the NASA Infrared Telescope Facility (IRTF),...

  8. River longitudinal profiles and bedrock incision models: Stream power and the influence of sediment supply

    Science.gov (United States)

    Sklar, Leonard; Dietrich, William E.

    The simplicity and apparent mechanistic basis of the stream power river incision law have led to its wide use in empirical and theoretical studies. Here we identify constraints on its calibration and application, and present a mechanistic theory for the effects of sediment supply on incision rates which spotlights additional limitations on the applicability of the stream power law. On channels steeper than about 20%, incision is probably dominated by episodic debris flows, and on sufficiently gentle slopes, sediment may bury the bedrock and prevent erosion. These two limits bound the application of the stream power law and strongly constrain the possible combination of parameters in the law. In order to avoid infinite slopes at the drainage divide in numerical models of river profiles using the stream power law it is commonly assumed that the first grid cell is unchanneled. We show, however, that the size of the grid may strongly influence the calculated equilibrium relief. Analysis of slope-drainage area relationships for a river network in a Northern California watershed using digital elevation data and review of data previously reported by Hack reveal that non-equilibrium profiles may produce well defined slope-area relationships (as expected in equilibrium channels), but large differences between tributaries may point to disequilibrium conditions. To explore the role of variations in sediment supply and transport capacity in bedrock incision we introduce a mechanistic model for abrasion of bedrock by saltating bedload. The model predicts that incision rates reach a maximum at intermediate levels of sediment supply and transport capacity. Incision rates decline away from the maximum with either decreasing supply (due to a shortage of tools) or increasing supply (due to gradual bed alluviation), and with either decreasing transport capacity (due to less energetic particle movement) or increasing transport capacity (due less frequent particle impacts per unit bed

  9. CO2 temperature-controlled laser soldering of pig trachea incisions in vitro using flexible albumin bands

    Science.gov (United States)

    Sharvit, Dan; Vasilyev, Tamar; Vasserman, Irena; Simhon, David; Kariv, Naam; DeRowe, Ari; Katzir, Abraham

    2005-04-01

    Resection of a segment of the trachea is a procedure applied for the removal of cervical tumors invading the trachea, or for the treatment of severe tracheal stenosis. The current method of anastomosis is based on multiple sutures. The main drawbacks of this method are: 1) A long procedure time, 2) An air leakage, and 3) An inflammatory response to the sutures. In this study we evaluated the feasibility and effectiveness of the use of temperature controlled CO2 laser soldering of incisions in pig tracheas in vitro. A transverse incision was made in a separated pig trachea. A flexible albumin band was prepared and was laser soldered with albumin solder to the outer surface of the trachea, covering the incision. The soldered trachea ends were sealed and the burst pressure was measured. In a series of in vitro experiments, the mean burst pressure was found to be 230 mm Hg. These preliminary results demonstrated that laser soldering using a flexible albumin band may be a useful method for sealing an incision in the trachea.

  10. Single-incision laparoscopic distal gastrectomy for early gastric cancer through a homemade single port access device.

    Science.gov (United States)

    Jiang, Zhi-Wei; Zhang, Shu; Wang, Gang; Zhao, Kun; Liu, Jiang; Ning, Li; Li, Jieshou

    2015-01-01

    We presented a series of single-incision laparoscopic distal gastrectomies for early gastric cancer patients through a type of homemade single port access device and some other conventional laparoscopic instruments. A single-incision laparoscopic distal gastrectomy with D1 + α lymph node dissection was performed on a 46 years old male patient who had an early gastric cancer. This single port access device has facilitated the conventional laparoscopic instruments to accomplish the surgery and we made in only 6 minutes. Total operating time for this surgery was 240 minutes. During the operation, there were about 100 milliliters of blood loss, and 17 lymph-nodes were retrieved. This homemade single port access device shows its superiority in economy and convenience for complex single-incision surgeries. Single-incision laparoscopic distal gastrectomy for early gastric cancer can be conducted by experienced laparoscopic surgeons. Fully take advantage of both SILS and fast track surgery plan can bring to successful surgeries with minimal postoperative pain, quicker mobilization, early recovery of intestinal function, and better cosmesis effect for the patients.

  11. NIR analysis of cellulose and lactose--application to ecstasy tablet analysis.

    Science.gov (United States)

    Baer, Ines; Gurny, Robert; Margot, Pierre

    2007-04-11

    Cellulose and lactose are the most frequently used excipients in illicit ecstasy production. The aim of this project was to use near infrared reflectance spectroscopy (NIRS) for the determination of the different chemical forms of these two substances, as well as for the differentiation of their origin (producer). It was possible to distinguish between the different chemical forms of both compounds, as well as between their origins (producers), although within limits. Furthermore, the possibilities to apply NIR for the analysis of substances such as found in illicit tablets were studied. First, a few cellulose and lactose samples were chosen to make mixtures with amphetamine at three degrees of purity (5, 10 and 15%), in order to study the resulting changes in the spectra as well as to simultaneously quantify amphetamine and identify the excipient. A PLS2 model could be build to predict concentrations and excipient. Secondarily, the technique was to be applied to real ecstasy tablets. About 40 ecstasy seizures were analysed with the aim to determine the excipient and to check them against each other. Identification of the excipients was not always obvious, especially when more than one excipient were present. However, a comparison between tablets appeared to give groups of similar samples. NIR analysis results in spectra representing the tablet blend as a whole taking into account all absorbing compounds. Although NIRS seems to be an appropriate method for ecstasy profiling, little is known about intra- and intervariability of compression batches.

  12. Field detection of CO and CH4 by NIR 2f modulation laser spectroscopy

    Directory of Open Access Journals (Sweden)

    A Khorsandi

    2011-12-01

    Full Text Available   A novel compact fiber-coupled NIR system based on a DFB diode laser source is employed as a portable and sensitive gas sensor for trace detection of combustion pollutant molecules. We demonstrate the performance of such an NIR gas sensor by tracing the absorption lines of CO and CH4 using 2f-WMS technique at moderate temperature of T ~ 600°C in the recuperator channel of an industrial furnace provided by Mobarakeh steel company. This measurement shows the excellent sensitivity of the applied NIR gas sensor to the on-line and in-situ monitoring of such molecular species.

  13. Normalized Urinary Flow at Puberty after Tubularized Incised Plate Urethroplasty for Hypospadias in Childhood.

    Science.gov (United States)

    Andersson, Marie; Doroszkiewicz, Monika; Arfwidsson, Charlotte; Abrahamsson, Kate; Sillén, Ulla; Holmdahl, Gundela

    2015-11-01

    An obstructive urinary flow pattern is frequently seen after tubularized incised plate urethroplasty for hypospadias. However, the significance of this finding has not been determined and long-term results are few. We describe postoperative long-term uroflowmetry results after puberty in males who underwent tubularized incised plate urethroplasty in childhood. A total of 126 boys underwent tubularized incised plate urethroplasty for distal penile to mid shaft hypospadias at Queen Silvia Children's Hospital in Gothenburg between 1999 and 2003. Of the patients 48 were toilet trained at surgery. We report on 40 patients who had data available at 2 and 12 months postoperatively, 7 years postoperatively and at puberty (median age 15.0 years, range 13.7 to 17.1). Of the patients 31 had distal and 9 had mid penile hypospadias. Clinical examination, urinary medical history, uroflowmetry and ultrasound measuring residual urine were performed. Maximum urinary flow was correlated to age and voided volume, using Miskolc nomograms for comparison of percentiles. At 1 year postoperatively 15 boys (37.5%) had normal urinary flow (above 25th percentile), compared to 16 (40%) at 7 years and 38 (95%) at puberty (p puberty for boys with hypospadias treated with tubularized incised plate urethroplasty. Unless symptoms occur, a conservative approach seems preferable. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. Nd:YAG laser incision of the vesical neck in obstructive BPH

    Science.gov (United States)

    Gilbert, Peter T. O.

    2003-06-01

    From February, 1995 through June, 2002, 68 patients underwent laser incision of the prostate at our clinic. By means of a 23 F cytoscope and a 600 micrometer lateral firing quartz fiber the vesical neck was incised at the 5 and 7 o'clock position at 60 W power. Total energy averaged 13648 J. Operative time did not exceed 15 minutes. General anesthesia was employed in all but one patient. 38 patients remained catheter-free whereas 30 patients were catheterized for two hours. Except for three cases, all patients were discharged on the same day, usually after the first micturition. Anti-inflammatory treatment was administered for two weeks, Cotrimoxazole for 5 days. No serious complications were encountered. Minor side effects included urinary retention (1 pat.), urinary infection (3 pat.) and retrograde ejaculation (1 pat.). Considering a mean follow-up of 21 months, the average Qmax improved enormously (25.4 ml/s versus 10.9 ml/s), as did residual urine volume (35 ml versus 95 ml) and IPSS (7.1 versus 20.5). Three patients required TUR-P 2-3 years after laser surgery and one patient underwent radical retropubic prostatectomy for prostate cancer 2 years later. In conclusion, Nd:YAG laser incision of the prostate is a simple, safe, reliable and cost-effective outpatient procedure.

  15. Magnetic resonance imaging in the repair of ruptured Achilles tendons. Morphological difference in healing process between conservative and surgical treatment

    International Nuclear Information System (INIS)

    Nakano, Tetsuo; Tsuruta, Takao; Abe, Yasuyuki; Tani, Akifumi; Koga, Toshimitsu; Shimizu, Yasuhiro

    1996-01-01

    We observed the healing process of ruptured Achilles tendons in a series using magnetic resonance imaging. In six cases, tendons were repaired percutaneously with limited skin incisions. Seven cases were treated conservatively using unique functional braces. MR imaging revealed two different modes of conjoining. In the conservatively treated group, tendons inclined to conjoin in a dumbbell shape. In the surgically treated group, they inclined to conjoin in a spindle shape. The diameters of the ruptured part are wider in the spindle shape compared to the dumbbell shape at all stages. These findings suggest that surgical treatment is favorable for acquiring earlier strength. (author)

  16. nirS-type denitrifying bacterial assemblages respond to environmental conditions of a shallow estuary.

    Science.gov (United States)

    Lisa, Jessica A; Jayakumar, Amal; Ward, Bess B; Song, Bongkeun

    2017-12-01

    Molecular analysis of dissimilatory nitrite reductase genes (nirS) was conducted using a customized microarray containing 165 nirS probes (archetypes) to identify members of sedimentary denitrifying communities. The goal of this study was to examine denitrifying community responses to changing environmental variables over spatial and temporal scales in the New River Estuary (NRE), NC, USA. Multivariate statistical analyses revealed three denitrifier assemblages and uncovered 'generalist' and 'specialist' archetypes based on the distribution of archetypes within these assemblages. Generalists, archetypes detected in all samples during at least one season, were commonly world-wide found in estuarine and marine ecosystems, comprised 8%-29% of the abundant NRE archetypes. Archetypes found in a particular site, 'specialists', were found to co-vary based on site specific conditions. Archetypes specific to the lower estuary in winter were designated Cluster I and significantly correlated by sediment Chl a and porewater Fe 2+ . A combination of specialist and more widely distributed archetypes formed Clusters II and III, which separated based on salinity and porewater H 2 S respectively. The co-occurrence of archetypes correlated with different environmental conditions highlights the importance of habitat type and niche differentiation among nirS-type denitrifying communities and supports the essential role of individual community members in overall ecosystem function. © 2017 Society for Applied Microbiology and John Wiley & Sons Ltd.

  17. Hybrid EEG–fNIRS-Based Eight-Command Decoding for BCI: Application to Quadcopter Control

    Science.gov (United States)

    Khan, Muhammad Jawad; Hong, Keum-Shik

    2017-01-01

    In this paper, a hybrid electroencephalography–functional near-infrared spectroscopy (EEG–fNIRS) scheme to decode eight active brain commands from the frontal brain region for brain–computer interface is presented. A total of eight commands are decoded by fNIRS, as positioned on the prefrontal cortex, and by EEG, around the frontal, parietal, and visual cortices. Mental arithmetic, mental counting, mental rotation, and word formation tasks are decoded with fNIRS, in which the selected features for classification and command generation are the peak, minimum, and mean ΔHbO values within a 2-s moving window. In the case of EEG, two eyeblinks, three eyeblinks, and eye movement in the up/down and left/right directions are used for four-command generation. The features in this case are the number of peaks and the mean of the EEG signal during 1 s window. We tested the generated commands on a quadcopter in an open space. An average accuracy of 75.6% was achieved with fNIRS for four-command decoding and 86% with EEG for another four-command decoding. The testing results show the possibility of controlling a quadcopter online and in real-time using eight commands from the prefrontal and frontal cortices via the proposed hybrid EEG–fNIRS interface. PMID:28261084

  18. NIR monitoring of in-service wood structures

    Science.gov (United States)

    Michela Zanetti; Timothy G. Rials; Douglas Rammer

    2005-01-01

    Near infrared spectroscopy (NIRS) was used to study a set of Southern Yellow Pine boards exposed to natural weathering for different periods of exposure time. This non-destructive spectroscopic technique is a very powerful tool to predict the weathering of wood when used in combination with multivariate analysis (Principal Component Analysis, PCA, and Projection to...

  19. On temporal connectivity of PFC via Gauss-Markov modeling of fNIRS signals.

    Science.gov (United States)

    Aydöre, Sergül; Mihçak, M Kivanç; Ciftçi, Koray; Akin, Ata

    2010-03-01

    Functional near-infrared spectroscopy (fNIRS) is an optical imaging method, which monitors the brain activation by measuring the successive changes in the concentration of oxy- and deoxyhemoglobin in real time. In this study, we present a method to investigate the functional connectivity of prefrontal cortex (PFC) Sby applying a Gauss-Markov model to fNIRS signals. The hemodynamic changes on PFC during the performance of cognitive paradigm are measured by fNIRS for 17 healthy adults. The color-word matching Stroop task is performed to activate 16 different regions of PFC. There are three different types of stimuli in this task, which can be listed as incongruent stimulus (IS), congruent stimulus (CS), and neutral stimulus (NS), respectively. We introduce a new measure, called "information transfer metric" (ITM) for each time sample. The behavior of ITMs during IS are significantly different from the ITMs during CS and NS, which is consistent with the outcome of the previous research, which concentrated on fNIRS signal analysis via color-word matching Stroop task. Our analysis shows that the functional connectivity of PFC is highly relevant with the cognitive load, i.e., functional connectivity increases with the increasing cognitive load.

  20. Infra Patellar Branch of Saphenous Nerve Injury during Hamstring Graft Harvest: Vertical versus Oblique Incisions.

    Science.gov (United States)

    Joshi, A; Kayasth, N; Shrestha, S; Kc, B R

    2016-09-01

    Autologous hamstring grafts are commonly used for anterior cruciate ligament reconstruction. The injury of infrapatellar branch of saphenous nerve is one of the concerns leading to various pattern of sensory loss in the operated leg. An oblique incision to harvest the graft has been reported to be better than the vertical one.The aim of this study was to compare the incidence, recovery of nerve injury and final outcome in patients with hamstring harvest of vertical or oblique incision. A total of 146 patients who underwent hamstring graft harvest for anterior cruciate ligament reconstruction, were included in the study. They were randomized into two (Vertical and Oblique) groups as per the incisions used. The sensory loss along the Infra Patellar Branch of Saphenous Nerve was documented on 3rd day. Recovery of the nerve injury was monitoredat three, six and 12 months follow-ups. At final follow up Tegner Lysholm score and scale was recorded to compare between two groups. The incidence of infrapatellar branch of saphenous nerve injury was 25% in vertical group and 16.36% in oblique group. Recovery of nerve injury started earlier in oblique group compared to vertical group. The mean TegnerLyshom score was not significantly different in both the groups. Oblique incision to harvest hamstring graft has lesser incidence of infrapatellar branch of saphenous nerve injury, recovers earlier and does not have any adverse effect on final outcome compared to the vertical incision.

  1. Near-infrared spectroscopy (NIRS) in a piglet model

    DEFF Research Database (Denmark)

    Clausen, Nicola Groes; Spielmann, Nelly; Ringer, Simone K.

    2017-01-01

    Near-infrared spectroscopy (NIRS) in a piglet model: readings are influenced by the colour of the cover Clausen NG1,2, Spielmann N1,3, Weiss M1,3, Ringer SK4 1Children’s Research Center, University Children’s Hospital of Zurich, Switzerland; 2Department of Anaesthesiology and Intensive Care, Odense....... The rSO2 was measured by placing NIRS sensors in the supra glabellar region. In 12 animals sensors were covered with a uni-coloured pink (P) napkin and a turquoise (T) napkin in a random order (Setting A). In further 13 animals sensors were covered with blue-coloured surgical drape (SD) and a napkin...... with a reddish SantaClaus (SC) motive (Setting B). Uncovered (UC) baseline values were captured and measurements obtained for a period of three minutes. During measurements, the animals were kept in normoterm, normotensive, normoglycaemic and normoxic condition. Inspired oxygen fraction and ventilatory settings...

  2. What's next in carbon ion radiotherapy at NIRS?

    International Nuclear Information System (INIS)

    Kamada, Tadashi

    2011-01-01

    Since its launch by the National Institute of Radiological Sciences (NIRS) in 1994, cancer therapy using heavy ion beams (carbon ion beams) has been used in approximately 5,500 patients. Accumulated clinical experience has identified certain types of malignant tumors that respond exclusively to this treatment. It has also been made clear that this therapy is capable of treating several other types of cancers safely in a relatively short period of time, effecting remission and/or cure without pain or discomfort in a few days or weeks. We can reasonably state that heavy ion radiotherapy has been established as a safe and effective treatment method. NIRS researchers are continuing to make every effort to develop more effective, efficient, and patient-friendly heavy ion irradiation systems. The result of this research and development is also expected to slash the attendant costs of heavy ion radiotherapy. (author)

  3. Staged abdominal closure with intramuscular tissue expanders and modified components separation technique of a giant incisional hernia after repair of a ruptured omphalocele

    Directory of Open Access Journals (Sweden)

    Yukihiro Tatekawa

    2016-07-01

    Full Text Available In patients with omphalocele, several different techniques are performed for repair of the abdominal wall defect. We present the case of a staged abdominal closure of a giant incisional hernia after repair of a ruptured omphalocele. At birth, skin flap coverage associated with silo formation occurred, but the abdominal wall defect remained, resulting in a giant abdominal hernia. To expand the layers of the abdominal wall, tissue expanders were placed between the bilateral internal oblique and transverses abdominis muscles. Postoperatively, a modified components separation technique was performed. The abdominal wall was closed in the midline. Upon closure of the skin in the midline, bilateral relaxing incisions were performed, covering the remaining defect with artificial dermis. At the age of one year and 7 months, the patient had no recurrent incisional hernia nor any wound complications.

  4. Virtual Incision Pattern Planning using Three-Dimensional Images for Optimization of Syndactyly Surgery

    Directory of Open Access Journals (Sweden)

    Inge A. Hoevenaren, MD

    2018-03-01

    Full Text Available Summary:. Syndactyly is a congenital condition characterized by fusion of the fingers. If not treated correctly during infancy, syndactyly may hinder the normal development of hand function. Many surgical techniques have been developed, with the main goal to create a functional hand with the smallest number of operative corrections. Therefore, exact preoperative planning of the reconstructive procedure is essential. An imaging method commonly used for preoperative planning is 3-dimensional (3D surface imaging. The goal of this study was to implement the use of this technique in hand surgery, by designing a virtual planning tool for a desyndactylization procedure based on 3D hand images. A 3D image of a silicon syndactyly model was made on which the incision pattern was virtually designed. A surgical template of this pattern was printed, placed onto the silicon model and delineated. The accuracy of the transfer from the virtual delineation toward the real delineation was calculated, resulting in a mean difference of 0.82 mm. This first step indicates that by using 3D images, a virtual incision pattern can be created and transferred back onto the patient successfully in an easy and accurate way by using a template. Thereafter, 3D hand images of 3 syndactyly patients were made, and individual virtual incision patterns were created. Each pattern was transferred onto the patient by using a 3D printed template. The resulting incision pattern needed minor modifications by the surgeon before the surgery was performed. Further research and validation are necessary to develop the virtual planning of desyndactylization procedures.

  5. [Determination of acidity and vitamin C in apples using portable NIR analyzer].

    Science.gov (United States)

    Yang, Fan; Li, Ya-Ting; Gu, Xuan; Ma, Jiang; Fan, Xing; Wang, Xiao-Xuan; Zhang, Zhuo-Yong

    2011-09-01

    Near infrared (NIR) spectroscopy technology based on a portable NIR analyzer, combined with kernel Isomap algorithm and generalized regression neural network (GRNN) has been applied to establishing quantitative models for prediction of acidity and vitamin C in six kinds of apple samples. The obtained results demonstrated that the fitting and the predictive accuracy of the models with kernel Isomap algorithm were satisfactory. The correlation between actual and predicted values of calibration samples (R(c)) obtained by the acidity model was 0.999 4, and for prediction samples (R(p)) was 0.979 9. The root mean square error of prediction set (RMSEP) was 0.055 8. For the vitamin C model, R(c) was 0.989 1, R(p) was 0.927 2, and RMSEP was 4.043 1. Results proved that the portable NIR analyzer can be a feasible tool for the determination of acidity and vitamin C in apples.

  6. Quantifying incision rates since the early Miocene: novelties, potentialities and limitations

    Science.gov (United States)

    Sartégou, A.; Braucher, R.; Blard, P. H.; Bourlès, D. L.; Zimmermann, L.; Tibari, B.; Voinchet, P.; Bahain, J. J.; Sorriaux, P.; Leanni, L.; Team, A.

    2017-12-01

    The rates and chronologies of valley incision are closely modulated by the tectonic uplift of active mountain ranges and were controlled by repeated climate changes during the Quaternary. The Pyrenees are a continental collision between the Iberian and Eurasian plates induced a double vergence orogen, which has been considered as a mature mountain range in spite of significant seismicity and evidence of neotectonics. Nevertheless, recent studies indicate that the range may have never reached a steady state. One option for resolving this controversy is to quantify the incision rates since the Miocene by reconstructing the vertical movement of geometric markers. However, the few available ages from the Pyrenean terrace systems do not exceed the middle Pleistocene. To enlarge the time span of this dataset, we studied alluvium-filled horizontal epiphreatic passages in limestone karstic networks, which represent former valley floors. They record the transient position of former local base levels during the process of valley deepening. We used various suitable geochronological methods (26Al/10Be, 10Be/21Ne, ESR and OSL burial durations on quartz) on intrakarstic alluvial deposits from three valleys of the central and eastern Pyrenees, as well as on a recent analogue. In the Pyrenean context, under particular conditions, these geochronometers allow us to document incision processes since 16-13 Ma, and to study influences of external forcing and eustatism. In comparison with other studies, it appears that incision rates are higher in the central Pyrenees and for the Spanish slope. However, the density of horizontal levels on an altimetric range, the geodynamical and paleoclimatic contexts, the reorganization of the drainage networks can make the filling stories of the networks more complex than expected. Indeed, these radiometric approaches may be limited when some formations are reworked inside and/or outside the karst. The validity of dosimetric methods in a mountainous

  7. Clinical and biomechanical outcome of minimal invasive and open repair of the Achilles tendon

    Directory of Open Access Journals (Sweden)

    Chan Alexander

    2011-12-01

    Full Text Available Abstract Introduction With evolutions in surgical techniques, minimally invasive surgical (MIS repair with Achillon applicator has been introduced. However, there is still a lack of literature to investigate into the clinical merits of MIS over open surgery. This study aims to investigate the correlation between clinical outcome, gait analysis and biomechanical properties comparing both surgical methods. Materials and methods A single centre retrospective review on all the consecutive operated patients between January 2004 and December 2008 was performed. Twenty-six patients (19 male and 7 female; age 40.4 ± 9.2 years had experienced a complete Achilles tendon rupture with operative repair. Nineteen of the patients, 10 MIS versus 9 open repairs (13 men with a mean age of 40.54 ± 10.43 (range 23-62 yrs and 6 women with a mean age of 45.33 ± 7.71 (range 35-57 yrs were further invited to attend a thorough clinical assessment using Holz's scale and biomechanical evaluation at a mean of 25.3 months after operation. This study utilized the Cybex II isokinetic dynamometer to assess the isokinetic peak force of plantar-flexion and dorsiflexion of both ankles. The patients were also invited to return to our Gait Laboratory for analysis. The eight-infrared camera motion capture system (VICON, UK was utilized for the acquisition of kinematic variables. Their anthropometric data was measured according to the Davis and coworkers' standard. Results The mean operative time and length of hospital stay were shorter in the MIS group. The operative time was 54.55 ± 15.15 minutes versus 68.80 ± 18.23 minutes of the MIS group and Open group respectively (p = 0.045, whereas length of stay was 3.36 ± 1.21 days versus 6.40 ± 3.70 days respectively (p = 0.039. There is statistically significant decrease (p = 0.005 in incision length in MIS group than the open surgery group, 3.23 ± 1.10 cm versus 9.64 ± 2.55 cm respectively. Both groups attained similar Holz

  8. Microsurgical head and neck tissue repair by visceral mini-autografting

    Directory of Open Access Journals (Sweden)

    A. D. Kaprin

    2015-01-01

    Full Text Available Objective. To minimize surgical trauma in patients with head and neck tumors during microsurgical plasty with visceral autografts.Subjects and methods. Clinical experience has been gained in the treatment of 53 patients with locally advanced craniofascial (n = 27 and oropharyngeal (n = 36 cancers. Abdominal organs were used for plastic closure of extensive defects after surgical resection. Paraumbilical incision allowing for an adequate approach into the abdominal cavity with minimal external trauma in the anterior abdominal wall was chosen as an access procedure. Video-assisted techniques were used to excise the midline aponeurosis. Donor organs, such as the omentum, greater curvature of the stomach, transverse colon, small intestine were taken through a mini-laparotomic incision to the anterior abdominal wall, then the vascular pedicle was exposed and a visceral autograft was made. After forming and cutting off the autograft, organ anastomoses were created extracorporeally.Results. Mini-access surgery could be completed in 50 of the 53 cases (4 patients had previously undergone abdominal interventions. Omental (n = 26, colo-omental (n = 15, gastro-omental (n = 7, and entero-omental (n = 5 flaps were made and prepared for autografting. No intra- or postoperative abdominal complications were found.Conclusion. Minimally invasive technologies used to create visceral authografts for head and neck tissue repair can minimize surgical trauma and reduce treatment duration. The indications for this access are the debilitating state of a cancer patient or the young age of a patient who does not wish to have an additional scar in the donor region.

  9. NirN Protein from Pseudomonas aeruginosa is a Novel Electron-bifurcating Dehydrogenase Catalyzing the Last Step of Heme d1 Biosynthesis*

    Science.gov (United States)

    Adamczack, Julia; Hoffmann, Martin; Papke, Ulrich; Haufschildt, Kristin; Nicke, Tristan; Bröring, Martin; Sezer, Murat; Weimar, Rebecca; Kuhlmann, Uwe; Hildebrandt, Peter; Layer, Gunhild

    2014-01-01

    Heme d1 plays an important role in denitrification as the essential cofactor of the cytochrome cd1 nitrite reductase NirS. At present, the biosynthesis of heme d1 is only partially understood. The last step of heme d1 biosynthesis requires a so far unknown enzyme that catalyzes the introduction of a double bond into one of the propionate side chains of the tetrapyrrole yielding the corresponding acrylate side chain. In this study, we show that a Pseudomonas aeruginosa PAO1 strain lacking the NirN protein does not produce heme d1. Instead, the NirS purified from this strain contains the heme d1 precursor dihydro-heme d1 lacking the acrylic double bond, as indicated by UV-visible absorption spectroscopy and resonance Raman spectroscopy. Furthermore, the dihydro-heme d1 was extracted from purified NirS and characterized by UV-visible absorption spectroscopy and finally identified by high-resolution electrospray ionization mass spectrometry. Moreover, we show that purified NirN from P. aeruginosa binds the dihydro-heme d1 and catalyzes the introduction of the acrylic double bond in vitro. Strikingly, NirN uses an electron bifurcation mechanism for the two-electron oxidation reaction, during which one electron ends up on its heme c cofactor and the second electron reduces the substrate/product from the ferric to the ferrous state. On the basis of our results, we propose novel roles for the proteins NirN and NirF during the biosynthesis of heme d1. PMID:25204657

  10. DNA alkylation lesions and their repair in human cells: modification of the comet assay with 3-methyladenine DNA glycosylase (AlkD).

    Science.gov (United States)

    Hašplová, Katarína; Hudecová, Alexandra; Magdolénová, Zuzana; Bjøras, Magnar; Gálová, Eliška; Miadoková, Eva; Dušinská, Mária

    2012-01-05

    3-methyladenine DNA glycosylase (AlkD) belongs to a new family of DNA glycosylases; it initiates repair of cytotoxic and promutagenic alkylated bases (its main substrates being 3-methyladenine and 7-methylguanine). The modification of the comet assay (single cell gel electrophoresis) using AlkD enzyme thus allows assessment of specific DNA alkylation lesions. The resulting baseless sugars are alkali-labile, and under the conditions of the alkaline comet assay they appear as DNA strand breaks. The alkylating agent methyl methanesulfonate (MMS) was used to induce alkylation lesions and to optimize conditions for the modified comet assay method with AlkD on human lymphoblastoid (TK6) cells. We also studied cellular and in vitro DNA repair of alkylated bases in DNA in TK6 cells after treatment with MMS. Results from cellular repair indicate that 50% of DNA alkylation is repaired in the first 60 min. The in vitro repair assay shows that while AlkD recognises most alkylation lesions after 60 min, a cell extract from TK6 cells recognises most of the MMS-induced DNA adducts already in the first 15 min of incubation, with maximum detection of lesions after 60 min' incubation. Additionally, we tested the in vitro repair capacity of human lymphocyte extracts from 5 individuals and found them to be able to incise DNA alkylations in the same range as AlkD. The modification of the comet assay with AlkD can be useful for in vitro and in vivo genotoxicity studies to detect alkylation damage and repair and also for human biomonitoring and molecular epidemiology studies. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  11. DNA repair , cell repair and radiosensitivity

    International Nuclear Information System (INIS)

    Zhestyanikov, V.D.

    1983-01-01

    Data obtained in laboratory of radiation cytology and literature data testifying to a considerable role of DNA repair in cell sensitivity to radiation and chemical DNA-tropic agents have been considered. Data pointing to the probability of contribution of inducible repair of DNA into plant cells sensitivity to X-rays are obtained. Certain violations of DNA repair do not result in the increase of radiosensitivity. It is assumed that in the cases unknown mechanisms of DNA repair operate

  12. Experimental radiation carcinogenesis is studies at NIRS

    International Nuclear Information System (INIS)

    Sado, Toshihiko

    1992-01-01

    Experimental radiation carcinogenesis studies conducted during the past decade at NIRS are briefly reviewed. They include the following: 1) Age dependency of susceptibility to radiation carcinogenesis. 2) Radiation-induced myeloid leukemia. 3) Mechanism of fractionated X-irradiation (FX) induced thymic lymphomas. 4) Significance of radiation-induced immunosuppression in radiation carcinogenesis in vivo. 5) Other ongoing studies. (author)

  13. Type of incision does not predict abdominal wall outcome after emergency surgery for colonic anastomotic leakage

    DEFF Research Database (Denmark)

    Jensen, Kristian Kiim; Oma, Erling; Harling, Henrik

    2017-01-01

    for anastomotic leakage were included with a median follow-up of 5.4 years. Incisional hernia occurred in 41 of 227 (15.3%) patients undergoing midline incision compared with 14 of 81 (14.7%) following transverse incision, P = 1.00. After adjusting for confounders, there was no association between the type...... not predict abdominal wall outcome after emergency surgery for colonic anastomotic leakage....

  14. Corticospinal excitability changes to anodal tDCS elucidated with NIRS-EEG joint-imaging

    DEFF Research Database (Denmark)

    Jindal, Utkarsh; Sood, Mehak; Chowdhury, Shubhajit Roy

    2015-01-01

    Transcranial direct current stimulation (tDCS) has been shown to modulate corticospinal excitability. We used near-infrared spectroscopy (NIRS) - electroencephalography (EEG) joint-imaging during and after anodal tDCS to measure changes in mean cerebral haemoglobin oxygen saturation (rSO2) along...... with changes in the log-transformed mean-power of EEG within 0.5 Hz - 11.25 Hz. In two separate studies, we investigated local post-tDCS alterations from baseline at the site of anodal tDCS using NIRS-EEG/tDCS joint-imaging as well as local post-tDCS alterations in motor evoked potentials (MEP...... that the innovative technologies for portable NIRS-EEG neuroimaging may be leveraged to objectively quantify the progress (e.g., corticospinal excitability alterations) and dose tDCS intervention as an adjuvant treatment during neurorehabilitation....

  15. Can post-sternotomy mediastinitis be prevented by a closed incision management system?

    Directory of Open Access Journals (Sweden)

    Dohmen, Pascal M.

    2014-09-01

    Full Text Available [english] Post-sternotomy mediastinitis is a serious complication after cardiothoracic surgery and contribute significantly to post-operative morbidity, mortality, and healthcare costs. Negative pressure wound therapy is today’s golden standard for post-sternotomy mediastinitis treatment. A systematic literature search was conducted at PubMed until October 2012 to analyse whether vacuum-assisted closure technique prevents mediastinitis after clean surgical incisions closure. Today’s studies showed reduction of post-sternotomy mediastinitis including a beneficial socio-economic impact. Current studies, however included only high-risk patients, hence furthermore, larger randomised controlled trials are warranted to clarify the benefit for using surgical incision vacuum management systems in the general patient population undergoing sternotomy and clarify risk factor interaction.

  16. Solo Single-Incision Laparoscopic Resectional Roux-en-Y Gastric Bypass for Morbid Obesity with Metabolic Syndrome.

    Science.gov (United States)

    Kang, So Hyun; Lee, Yoontaek; Park, Young Suk; Ahn, Sang-Hoon; Park, Do Joong; Kim, Hyung-Ho

    2017-12-01

    With the advancement of laparoscopic devices and surgical technology, the era of minimal invasive surgery has progressed to reduced-port surgery, and finally to single-incision laparoscopic surgery (SILS). Several reports show successful application of SILS to various types of bariatric surgery. Oftentimes, this requires a skilled and experienced scopist to perform the procedure. To overcome the technical difficulties of single-incision Roux-en-Y gastric bypass, a manual scope holder was used instead of an assistant scopist, greatly stabilizing the field of view. This allows the surgery to be performed at any time without being influenced by the need of a highly experienced scopist. In this report, we describe in detail the world's first solo single-incision laparoscopic resectional Roux-en-Y gastric bypass.

  17. Evaluation of PE Films Having NIR-Reflective Additives for Greenhouse Applications in Arid Regions

    Directory of Open Access Journals (Sweden)

    Syed K. H. Gulrez

    2013-01-01

    Full Text Available Linear-low-density-polyethylene- (LLDPE- based formulations with several near-infrared- (NIR- reflective pigments were prepared by melt blending technique and their subsequent films were prepared by blown film extrusion process. Thermal properties of these films were evaluated using differential scanning calorimetry (DSC. The results showed that the melting and crystallization temperatures (Tm and Tc, resp. of these formulations were almost similar to that of control resin. The melt viscosity was measured by stress-controlled rotational rheometer and melt flow index (MFI instruments. Rheological measurements indicated that the blend formulations with NIR-reflective additive have similar melt viscoelastic behavior (storage modulus and dynamic viscosity to the control resin. The mechanical test performed on NIR-reflective films showed similar values of tensile strength for blend samples as that of control resin. The spectral radiometric properties of the blend films were evaluated in the solar wavelength range of 200–1100 nm and found to be improved over the control sample without having NIR-reflective pigment.

  18. Role of DNA repair in repair of cytogenetic damages. Slowly repaired DNA injuries involved in cytogenetic damages repair

    International Nuclear Information System (INIS)

    Zaichkina, S.I.; Rozanova, O.M.; Aptikaev, G.F.; Ganassi, E.Eh.

    1989-01-01

    Caffeine was used to study the kinetics of cytogenetic damages repair in Chinese hamster fibroblasts. Its half-time (90 min) was shown to correlate with that of repair of slowly repaired DNA damages. The caffeine-induced increase in the number of irreparable DNA damages, attributed to inhibition of double-strand break repair, is in a quantitative correlation with the effect of the cytogenetic damage modification

  19. Determination of SFC, FFA, and equivalent reaction time for enzymatically interestified oils using NIRS

    DEFF Research Database (Denmark)

    Houmøller, Lars P.; Kristensen, Dorthe; Rosager, Helle

    2007-01-01

    The use of near infrared spectroscopy (NIRS) for rapid determination of the degree of interesterification of blends of palm stearin, coconut oil, and rapeseed oil obtained using an immobilized Thermomyces lanuginosa lipase at 70 ◦C was investigated. Interesterification was carried out by applying...... that NIRS could be used to replace the traditional methods for determining FFA and SFC in vegetable oils.It was possible to monitor the activity of the immobilized enzyme for interesterification of margarine oils by predicting the equivalent reaction time in a batch reactor from NIR spectra. Root mean...... square errors of prediction for two different oil blends interesterified for 300 and 170 min were 21 and 12 min, respectively....

  20. Laparoendoscopic single-site repair of bladder rupture using a home-made single-port device: initial experience of treatment for a traumatic intraperitoneal bladder rupture.

    Science.gov (United States)

    Lee, Joo Yong; Kang, Dong Hyuk; Lee, Seung Wook

    2012-06-01

    We report our initial experience with a laparoendoscopic single-site (LESS) repair of a bladder rupture using a home-made single-port device. A 37-year-old man presented to the emergency department with complaints of voiding difficulty and gross hematuria after blunt trauma. Cystography and computed tomography revealed an intraperitoneal bladder rupture. The patient underwent LESS repair of a bladder rupture using the Alexis wound retractor, which was inserted through the umbilical incision. A home-made single-port device was made by fixing 6½ surgical gloves to the outer rim of the retractor and securing the glove finger to the end of 3 trocars with a tie. Using the flexible laparoscopic instruments and rigid instruments, LESS surgery was performed using a procedure similar to conventional laparoscopic surgery. The patient did not have any voiding problem after removal of the urethral Foley catheter on the 10th postoperative day. To our knowledge, this is the first published report of LESS repair of a traumatic bladder rupture using a home-made single-port device in the literature.

  1. Pyrimidine dimers in Drosophila chromatin become increasingly accessible after irradiation

    International Nuclear Information System (INIS)

    Harris, P.V.; Boyd, J.B.

    1987-01-01

    A prokaryotic DNA-repair enzyme has been utilized as a probe for changes in the accessibility of pyrimidine dimers in Drosophila chromatin following UV irradiation. The results demonstrate a rapid cellular response to physiologically relevant doses of radiation which results in at least a 40% increase in accessible dimers. This increase occurs in two incision-deficient mutants which indicates that the excision-repair process, at or beyond the incision step, is not required or responsible for the increase. In the absence of excision the increase in accessibility persists for a least 2 days following irradiation. The observed increase in accessibility is inhibited by both novobiocin and coumermycin. These inhibitors do not inhibit the initial rate of incision, but do reduce dimer excision measured over more extended periods. A pre-incision process is proposed which actively exposes DNA lesions to excision repair. A fraction of the genome is postulated to be accessible without the intervention of that process. (Auth.)

  2. Maternal infection rates after cesarean delivery by Pfannenstiel or Joel-Cohen incision: a multicenter surveillance study.

    Science.gov (United States)

    Dumas, Anne Marie; Girard, Raphaële; Ayzac, Louis; Caillat-Vallet, Emmanuelle; Tissot-Guerraz, Françoise; Vincent-Bouletreau, Agnès; Berland, Michel

    2009-12-01

    Our purpose was to evaluate maternal nosocomial infection rates according to the incision technique used for caesarean delivery, in a routine surveillance study. This was a prospective study of 5123 cesarean deliveries (43.2% Joel-Cohen, 56.8% Pfannenstiel incisions) in 35 maternity units (Mater Sud Est network). Data on routine surveillance variables, operative duration, and three additional variables (manual removal of the placenta, uterine exteriorization, and/or cleaning of the parieto-colic gutter) were collected. Multiple logistic regression analysis was used to identify independent risk factors for infection. The overall nosocomial infection and endometritis rates were higher for the Joel-Cohen than Pfannenstiel incision (4.5% vs. 3.3%, 0.8% vs. 0.3%, respectively). The higher rate of nosocomial infections with the Joel-Cohen incision was due to a greater proportion of patients presenting risk factors (i.e., emergency delivery, primary cesarean, blood loss > or =800 mL, no manual removal of the placenta and no uterine exteriorization). However, the Joel-Cohen technique was an independent risk factor for endometritis. The Joel-Cohen technique is faster than the Pfannenstiel technique but is associated with a higher incidence of endometritis.

  3. Addition of rectus sheath relaxation incisions to emergency midline laparotomy for peritonitis to prevent fascial dehiscence.

    Science.gov (United States)

    Marwah, Sanjay; Marwah, Nisha; Singh, Mandeep; Kapoor, Ajay; Karwasra, Rajender Kumar

    2005-02-01

    The incidence of fascial dehiscence and incisional hernia after two methods for abdominal wound closure (rectus sheath relaxation incisions and conventional mass closure) was studied in a randomized prospective clinical trial in a consecutive series of 100 patients undergoing midline laparotomy for peritonitis. The two groups were well matched for etiologies of peritonitis, the surgical procedures performed, and the presence of known risk factors for fascial dehiscence. Fifty patients each were randomized either to the conventional continuous mass closure procedure or the rectus sheath relaxation incision technique (designed to increase wound elasticity and decrease tension in the suture line) using identical polypropylene sutures. The incidence of postoperative complications such as duration of ileus, chest infection, and wound infection were not statistically different between the two groups. The intensity of postoperative pain in the rectus sheath relaxation incision group was significantly less. The incidence of wound hematoma was significantly increased in the rectus sheath relaxation incision group. The incidences of fascial dehiscence (16% vs,28%; p cases of peritonitis using the rectus sheath relaxation technique is safe and less painful, provides increased wound elasticity and decreased tension on the suture line, and significantly decreases the incidence of wound dehiscence.

  4. Application of computer-aided three-dimensional skull model with rapid prototyping technique in repair of zygomatico-orbito-maxillary complex fracture.

    Science.gov (United States)

    Li, Wei Zhong; Zhang, Mei Chao; Li, Shao Ping; Zhang, Lei Tao; Huang, Yu

    2009-06-01

    With the advent of CAD/CAM and rapid prototyping (RP), a technical revolution in oral and maxillofacial trauma was promoted to benefit treatment, repair of maxillofacial fractures and reconstruction of maxillofacial defects. For a patient with zygomatico-facial collapse deformity resulting from a zygomatico-orbito-maxillary complex (ZOMC) fracture, CT scan data were processed by using Mimics 10.0 for three-dimensional (3D) reconstruction. The reduction design was aided by 3D virtual imaging and the 3D skull model was reproduced using the RP technique. In line with the design by Mimics, presurgery was performed on the 3D skull model and the semi-coronal incision was taken for reduction of ZOMC fracture, based on the outcome from the presurgery. Postoperative CT and images revealed significantly modified zygomatic collapse and zygomatic arch rise and well-modified facial symmetry. The CAD/CAM and RP technique is a relatively useful tool that can assist surgeons with reconstruction of the maxillofacial skeleton, especially in repairs of ZOMC fracture.

  5. Feasibility of single-incision laparoscopic surgery for appendicitis in abnormal anatomical locations: A single surgeon′s initial experience

    Directory of Open Access Journals (Sweden)

    Sanoop K Zachariah

    2013-01-01

    Full Text Available Background: Single-incision laparoscopic surgery is considered as a more technically demanding procedure than the standard laparoscopic surgery. Based on an initial and early experience, single-incision laparoscopic appendectomy (LA was found to be technically advantageous for dealing with appendicitis in unusual anatomical locations. This study aims to highlight the technical advantages of single-incision laparoscopic surgery in dealing with the abnormally located appendixes and furthermore report a case of acute appendicitis occurring in a sub-gastric position, which is probably the first such case to be reported in English literature. Materials and Methods: A retrospective analysis of the first 10 cases of single-incision LA which were performed by a single surgeon is presented here. Results: There were seven females and three males. The mean age of the patients was 30.6 (range 18-52 years, mean BMI was 22.7 (range 17-28 kg/m 2 and the mean operative time was 85.5 (range 45-150 min. The mean postoperative stay was 3.6 (range 1-7 days. The commonest position of the appendix was retro-caecal (50% followed by pelvic (30%. In three cases the appendix was found to be in abnormal locations namely sub-hepatic, sub-gastric and deep pelvic or para-vesical or para-rectal. All these cases could be managed with this technique without any conversions Conclusion: Single-incision laparoscopic surgery appears to be a feasible and safe technique for dealing with appendicitis in rare anatomical locations. Appendectomy may be a suitable procedure for the initial training in single-incision laparoscopic surgery.

  6. [Surgical treatment for incisions fat colliquation or infections at early stage after operation of lumbar disc herniation].

    Science.gov (United States)

    Guan, Ting-Jin; Zheng, Liang-Guo; Sun, Peng; Li, Xing-Xue

    2014-05-01

    To explore the reason, key diagnosic point and therapeutic method of the incisions fat colliquation or infections at early stage after operation of lumbar disc herniation. From July 2007 to May 2012, clinical data of 11 patients with incision fat liquefaction or early infection after lumbar discectomy were retrospectively analyzed. There were 5 males and 6 females with an average age of 43.1 years, and the mean time of incisions fat colliquation or infection was 5 days and a half after operation. The main clinical features included local wound pain aggravating, fervescence, fresh seepage in the wound, and blood inflammatory index increased, etc. The wound could heal at the first treatment stage or not was an evaluation standard of curative effect. All patients were followed up with an average period of 21 months. The wounds of 10 cases healed at the first stage without recurrence and complications. In 1 case infected by staphylococcus aureus, distal part of the wound present local red, swelling and with wave motion at 2 months after operation, staphylococcus aureus infection was confirmed after puncture and bacterial culture, and 1 thrum was found after local incision. The wound healed after change dressings for 1 week, without recurrence after followed up for 13 months. Preventing the risk factors before operation, minimizing invasive technique during operation reasonable antibiotics application for the lumbar operation reguiring placement objects, and correctly handling with wound after operation could prevent and reduce the incidence of incisions fat liquefaction or infection after operation of lumbar disc herniation. For incision fat liquefaction or infection, early diagnosis, debridement, VSD negative pressure irrigation and drainage, to choosing sensitive antibiotics according to the results of drug sensitivity, may contribute to wound early healing and decrease complication.

  7. Feasibility of Performing Total Skin-Sparing Mastectomy in Patients With Prior Circumareolar Mastopexy or Reduction Mammoplasty Incisions.

    Science.gov (United States)

    Vaughn, Carolyn J; Peled, Anne Warren; Esserman, Laura J; Foster, Robert D

    2013-06-19

    Total skin-sparing mastectomy (TSSM) techniques with preservation of the nipple-areolar complex (NAC) skin are becoming increasingly popular due to improved cosmesis without compromise in oncologic safety. However, these techniques are not routinely offered to patients who have undergone previous breast surgery involving circumareolar incisions due to concern for NAC viability. We reviewed the outcomes of TSSM in 11 patients who underwent 21 TSSM procedures at our institution between 2008 and 2011. All patients had undergone previous breast surgery including reduction mammaplasty (7 breasts), mastopexy (4 breasts), augmentation (3 breasts), and combined mastopexy-augmentation (7 breasts). Incisions from previous breast surgery included circumareolar (11 cases) and Wise pattern (10 cases) incisions. All patients underwent TSSM through an inframammary incision followed by immediate tissue expander reconstruction and subsequent implant exchange. Patient demographics, previous breast surgery details, tumor and treatment characteristics, and postoperative complications were reviewed. Mean patient age was 43 years (range, 35-53 years) and mean body mass index was 24 kg/m (range, 19-32 kg/m). Mean follow-up was 10.2 months (range, 3-20 months).Indications for TSSM included prophylactic risk reduction in 10 cases, in situ cancer in 2 cases, and invasive cancer in 9 cases. Mean time from previous breast surgery to mastectomy was 6.9 years (range, 6 months-26 years). Major complications requiring operative reintervention included 1 (4.8%) case of cellulitis requiring expander removal and 2 (9.5%) cases of wound breakdown requiring operative closure. There were no complications involving the NAC. Total skin-sparing mastectomy with immediate reconstruction can safely be performed in patients who have undergone previous breast surgery involving circumareolar incisions. Our preferred technique in this group of patients is to perform TSSM through an inframammary incision with 2

  8. Cannabidiol Is a Potential Therapeutic for the Affective-Motivational Dimension of Incision Pain in Rats

    Directory of Open Access Journals (Sweden)

    Karina Genaro

    2017-06-01

    Full Text Available Background: Pain involves different brain regions and is critically determined by emotional processing. Among other areas, the rostral anterior cingulate cortex (rACC is implicated in the processing of affective pain. Drugs that interfere with the endocannabinoid system are alternatives for the management of clinical pain. Cannabidiol (CBD, a phytocannabinoid found in Cannabis sativa, has been utilized in preclinical and clinical studies for the treatment of pain. Herein, we evaluate the effects of CBD, injected either systemically or locally into the rACC, on mechanical allodynia in a postoperative pain model and on the negative reinforcement produced by relief of spontaneous incision pain. Additionally, we explored whether CBD underlies the reward of pain relief after systemic or rACC injection.Methods and Results: Male Wistar rats were submitted to a model of incision pain. All rats had mechanical allodynia, which was less intense after intraperitoneal CBD (3 and 10 mg/kg. Conditioned place preference (CPP paradigm was used to assess negative reinforcement. Intraperitoneal CBD (1 and 3 mg/kg inverted the CPP produced by peripheral nerve block even at doses that do not change mechanical allodynia. CBD (10 to 40 nmol/0.25 μL injected into the rACC reduced mechanical allodynia in a dose-dependent manner. CBD (5 nmol/0.25 μL did not change mechanical allodynia, but reduced peripheral nerve block-induced CPP, and the higher doses inverted the CPP. Additionally, CBD injected systemically or into the rACC at doses that did not change the incision pain evoked by mechanical stimulation significantly produced CPP by itself. Therefore, a non-rewarding dose of CBD in sham-incised rats becomes rewarding in incised rats, presumably because of pain relief or reduction of pain aversiveness.Conclusion: The study provides evidence that CBD influences different dimensions of the response of rats to a surgical incision, and the results establish the rACC as a

  9. Remote Estimation of Chlorophyll-a in Inland Waters by a NIR-Red-Based Algorithm: Validation in Asian Lakes

    Directory of Open Access Journals (Sweden)

    Gongliang Yu

    2014-04-01

    Full Text Available Satellite remote sensing is a highly useful tool for monitoring chlorophyll-a concentration (Chl-a in water bodies. Remote sensing algorithms based on near-infrared-red (NIR-red wavelengths have demonstrated great potential for retrieving Chl-a in inland waters. This study tested the performance of a recently developed NIR-red based algorithm, SAMO-LUT (Semi-Analytical Model Optimizing and Look-Up Tables, using an extensive dataset collected from five Asian lakes. Results demonstrated that Chl-a retrieved by the SAMO-LUT algorithm was strongly correlated with measured Chl-a (R2 = 0.94, and the root-mean-square error (RMSE and normalized root-mean-square error (NRMS were 8.9 mg∙m−3 and 72.6%, respectively. However, the SAMO-LUT algorithm yielded large errors for sites where Chl-a was less than 10 mg∙m−3 (RMSE = 1.8 mg∙m−3 and NRMS = 217.9%. This was because differences in water-leaving radiances at the NIR-red wavelengths (i.e., 665 nm, 705 nm and 754 nm used in the SAMO-LUT were too small due to low concentrations of water constituents. Using a blue-green algorithm (OC4E instead of the SAMO-LUT for the waters with low constituent concentrations would have reduced the RMSE and NRMS to 1.0 mg∙m−3 and 16.0%, respectively. This indicates (1 the NIR-red algorithm does not work well when water constituent concentrations are relatively low; (2 different algorithms should be used in light of water constituent concentration; and thus (3 it is necessary to develop a classification method for selecting the appropriate algorithm.

  10. Biomechanical comparison of an all-soft suture anchor with a modified Broström-Gould suture repair for lateral ligament reconstruction.

    Science.gov (United States)

    Brown, Christopher A; Hurwit, Daniel; Behn, Anthony; Hunt, Kenneth J

    2014-02-01

    Anatomic repair is indicated for patients who have recurrent lateral ankle instability despite nonoperative measures. There is no difference in repair stiffness, failure torque, or failure angle between specimens repaired with all-soft suture anchors versus the modified Broström-Gould technique with sutures only. Controlled laboratory study. In 10 matched pairs of human cadaveric ankles, the anterior talofibular ligament (ATFL) was incised from its origin on the fibula. After randomization, 1 ankle was repaired to its anatomic insertion using two 1.4-mm JuggerKnot all-soft suture anchors; the other ankle was repaired with a modified Broström-Gould technique using 2-0 FiberWire. All were augmented using the inferior extensor retinaculum. All ankles were mounted to the testing machine in 20° of plantar flexion and 15° of internal rotation and loaded to failure after the repair. Stiffness, failure torque, and failure angle were recorded and compared using a paired Student t test with a significance level set at P anchors pulled out of bone. The primary mode of failure was pulling through the ATFL tissue. There was no statistical difference in strength or stiffness between a 1.4-mm all-soft suture anchor and a modified Broström-Gould repair with 2-0 FiberWire. The primary mode of failure was at the tissue level rather than knot failure or anchor pullout. The particular implant choice (suture only, tunnel, anchor) in repairing the lateral ligament complex may not be as important as the time to biological healing. The suture-only construct as described in the Broström-Gould repair was as strong as all-soft suture anchors, and the majority of the ankles failed at the tissue level. For those surgeons whose preference is to use anchor repair, this novel all-soft suture anchor may be an alternative to other larger anchors, as none failed by pullout.

  11. Development of nondestructive sorting method for brown bloody eggs using VIS/NIR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hong Seock; Kim, Dae Yong; Kandpal, Lalit Mohan; Lee, Sang Dae; Cho, Byoung Kwan [Dept. of Biosystems Machinery Engineering, College of Agriculture and Life Science, Chungnam National University, Daejeon (Korea, Republic of); Mo, Chang Yeun; Hong, Soon Jung [Rural Development Administration, Jeonju (Korea, Republic of)

    2014-02-15

    The aim of this study was the non-destructive evaluation of bloody eggs using VIS/NIR spectroscopy. The bloody egg samples used to develop the sorting mode were produced by injecting chicken blood into the edges of egg yolks. Blood amounts of 0.1, 0.7, 0.04, and 0.01 mL were used for the bloody egg samples. The wavelength range for the VIS/NIR spectroscopy was 471 to 1154 nm, and the spectral resolution was 1.5nm. For the measurement system, the position of the light source was set to, and the distance between the light source and samples was set to 100 mm. The minimum exposure time of the light source was set to 30 ms to ensure the fast sorting of bloody eggs and prevent heating damage of the egg samples. Partial least squares-discriminant analysis (PLS-DA) was used for the spectral data obtained from VIS/NIR spectroscopy. The classification accuracies of the sorting models developed with blood samples of 0.1, 0.07, 0.04, and 0.01 mL were 97.9%, 98.9%, 94.8%, and 86.45%, respectively. In this study, a novel nondestructive sorting technique was developed to detect bloody brown eggs using spectral data obtained from VIS/NIR spectroscopy.

  12. Design and development of a blood vessel localization system using a Nir viewer; Diseno y desarrollo de un sistema de localizacion de vasos sanguineos mediante Visor NIR

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez R, A.; Plascencia C, L. E.; Cordova F, T.; Padilla R, N., E-mail: angelicahr@fisica.ugto.mx [Universidad de Guanajuato, 37150 Leon, Guanajuato (Mexico)

    2017-10-15

    In addition to the multiple applications of ionizing radiation in clinical diagnosis there is the possibility of using another part of the electromagnetic spectrum such as near infrared (Nir). This paper presents the design and construction of a Nir Biosensor in a range between 800 and 900 nm, which allows the visualization of blood vessels for the venepuncture procedure with the aim of reducing the trauma of venous access to patients of all ages. The possibility that the device is used in the location of venous ulcers as an alternative to veno grams obtained by X-rays is also explored. (Author)

  13. Disposable skin staplers for closure of linear gastrointestinal incisions in dogs.

    Science.gov (United States)

    Schwartz, Zeev; Coolman, Bradley R

    2018-02-01

    To report the clinical features and outcomes of linear gastrointestinal incisions closed with skin staples in dogs. Historical cohort study. 333 client-owned dogs. Medical records from 1 private referral hospital were searched for dogs that underwent gastrointestinal surgery between November 1999 and October 2015. Cases were included if skin staplers were used to close linear gastrointestinal incisions. Information regarding preoperative, surgical, and postoperative factors was collected. Complications were diagnosed in 8 of 245 (3.27%) dogs, including 3 of 245 (1.22%) dogs that died or were euthanized, 3 of 245 (1.22%) dogs with incisional dehiscence, and 2 of 245 (0.81%) dogs with attachment of a linear foreign body to the staples at the intestinal lumen. Dehiscence was noted at the enterotomy sites in 3 dogs at a mean time of 44 hours after surgery (SD ± 6.93). Two dogs presented with another linear foreign body that was attached to the staples in the intestinal lumen at postoperative days 24 and 42. The risk factors associated with incisional dehiscence included multiple gastrointestinal incisions performed in 1 surgery (χ 2 , P indication for surgical intervention, surgery location in the gastrointestinal tract, or surgeon experience and incisional dehiscence. Skin staplers provide safe and effective closure of gastrotomies, enterotomies, and colonotomies in dogs. This method is reliable, efficient, and affordable in the hands of veterinary surgeons with varying skill levels. © 2017 The American College of Veterinary Surgeons.

  14. Modeling Long-Term Fluvial Incision : Shall we Care for the Details of Short-Term Fluvial Dynamics?

    Science.gov (United States)

    Lague, D.; Davy, P.

    2008-12-01

    Fluvial incision laws used in numerical models of coupled climate, erosion and tectonics systems are mainly based on the family of stream power laws for which the rate of local erosion E is a power function of the topographic slope S and the local mean discharge Q : E = K Qm Sn. The exponents m and n are generally taken as (0.35, 0.7) or (0.5, 1), and K is chosen such that the predicted topographic elevation given the prevailing rates of precipitation and tectonics stay within realistic values. The resulting topographies are reasonably realistic, and the coupled system dynamics behaves somehow as expected : more precipitation induces increased erosion and localization of the deformation. Yet, if we now focus on smaller scale fluvial dynamics (the reach scale), recent advances have suggested that discharge variability, channel width dynamics or sediment flux effects may play a significant role in controlling incision rates. These are not factored in the simple stream power law model. In this work, we study how these short- term details propagate into long-term incision dynamics within the framework of surface/tectonics coupled numerical models. To upscale the short term dynamics to geological timescales, we use a numerical model of a trapezoidal river in which vertical and lateral incision processes are computed from fluid shear stress at a daily timescale, sediment transport and protection effects are factored in, as well as a variable discharge. We show that the stream power law model might still be a valid model but that as soon as realistic effects are included such as a threshold for sediment transport, variable discharge and dynamic width the resulting exponents m and n can be as high as 2 and 4. This high non-linearity has a profound consequence on the sensitivity of fluvial relief to incision rate. We also show that additional complexity does not systematically translates into more non-linear behaviour. For instance, considering only a dynamical width

  15. Effects of Varying Gravity Levels on fNIRS Headgear Performance and Signal Recovery

    Science.gov (United States)

    Mackey, Jeffrey R.; Harrivel, Angela R.; Adamovsky, Grigory; Lewandowski, Beth E.; Gotti, Daniel J.; Tin, Padetha; Floyd, Bertram M.

    2013-01-01

    This paper reviews the effects of varying gravitational levels on functional Near-Infrared Spectroscopy (fNIRS) headgear. The fNIRS systems quantify neural activations in the cortex by measuring hemoglobin concentration changes via optical intensity. Such activation measurement allows for the detection of cognitive state, which can be important for emotional stability, human performance and vigilance optimization, and the detection of hazardous operator state. The technique depends on coupling between the fNIRS probe and users skin. Such coupling may be highly susceptible to motion if probe-containing headgear designs are not adequately tested. The lack of reliable and self-applicable headgear robust to the influence of motion artifact currently inhibits its operational use in aerospace environments. Both NASAs Aviation Safety and Human Research Programs are interested in this technology as a method of monitoring cognitive state of pilots and crew.

  16. TROPOMI and TROPI: UV/VIS/NIR/SWIR instruments

    NARCIS (Netherlands)

    Levelt, P.F.; Oord, G.H.J. van den; Dobber, M.; Eskes, H.; Weele, M. van; Veefkind, P.; Oss, R. van; Aben, I.; Jongma, R.T.; Landgraf, J.; Vries, J. de; Visser, H.

    2006-01-01

    TROPOMI (Tropospheric Ozone-Monitoring Instrument) is a five-channel UV-VIS-NIR-SWIR non-scanning nadir viewing imaging spectrometer that combines a wide swath (114°) with high spatial resolution (10 × 10 km 2). The instrument heritage consists of GOME on ERS-2, SCIAMACHY on Envisat and, especially,

  17. European Hernia Society guidelines on the closure of abdominal wall incisions

    DEFF Research Database (Denmark)

    Muysoms, F E; Antoniou, S A; Bury, K

    2015-01-01

    using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach and methodological guidance was taken from Scottish Intercollegiate Guidelines Network (SIGN). The literature search included publications up to April 2014. The guidelines were written using the AGREE II...... of rapidly absorbable sutures. It is suggested using a slowly absorbable monofilament suture in a single layer aponeurotic closure technique without separate closure of the peritoneum. A small bites technique with a suture to wound length (SL/WL) ratio at least 4/1 is the current recommended method......, it is suggested using the smallest trocar size adequate for the procedure and closure of the fascial defect if trocars larger or equal to 10 mm are used. For single incision laparoscopic surgery, we suggest meticulous closure of the fascial incision to avoid an increased risk of incisional hernias....

  18. The influence of lip form on incisal display with lips in repose on the esthetic preferences of dentists and lay people.

    Science.gov (United States)

    Kim, Jee; Topolski, Richard; Dickinson, Douglas; Ramos, Van

    2017-09-01

    Information is lacking for viewer preferences for incisal display with lips in repose. The purpose of this online survey was to establish measurement parameters to classify and define a lip form and to evaluate the influence of lip form on dentists' and laypersons' preferences for the amount of incisal display with lips in repose. Computer-generated male and female models were created using 3 different lip forms each, straight, moderate, and high. Three images of these models (frontal full face, zoomed-in frontal around the mouth, and oblique zoomed-in image of the mouth) were arranged in an interactive survey that was disseminated on the Websites Facebook, Instagram, DentalTown and by word-of-mouth. Respondents manipulated the incisal display of all 3 images in unison, using a slide bar, and the resulting incisal display was measured in millimeters and served as the primary dependent measure. Survey demographic data were obtained from an online survey site. Data were assessed for skewness, kurtosis, and outliers and analyzed with 5-way ANOVA: 2 sex levels for model, 2 levels for sex of respondent, 3 levels for lip height, 3 levels for occupation, and 5 levels of ethnicity, with multiple comparisons corrected with Bonferroni adjustments and post hoc comparisons performed using the Scheffé test (α=.05 for all comparisons). A total of 1039 individuals consented to the study. A final sample size of 687 respondents was obtained after excluding 352 who failed to complete the survey. The results indicated that lip form affected the esthetic perception of incisal display significantly (P<.001), with a preference for a greater amount of incisal display corresponding with increasing lip forms. Sex of the model was also significant, with greater incisal display being preferred for female faces. A significant difference was found for respondents' ethnicity, with African Americans generally preferring smaller incisal displays than other ethnic groups. No other main effects

  19. Incisive papilla and positions of maxillary anterior teeth among ...

    African Journals Online (AJOL)

    Results: One hundred and twelve maxillary casts generated from participants aged 18-35 years (mean age 22.39±2.00 years), with well aligned arches were studied. The maxillary central incisor exhibited a mean of 14.93±1.52mm from the posterior limit of the incisive papilla while the inter-canine line scored a mean of ...

  20. EXPERIENCE WITH THE OPEN TENSION-FREE HERNIA REPAIR

    Directory of Open Access Journals (Sweden)

    Slavko Rakovec

    2002-03-01

    Full Text Available Background. All old techniques of herniorrhaphy involve approximation of tissues under tension, which accounts for their unreliability. Therefore the recovery time is long and the recurrence rate unacceptably high. The new methods using a mesh patch of polypropylene allow for a tensionfree repair, which is much more reliable. So they are associated with a shorter recovery time and carry a low probability of recurrence. The tension-free repair can be accomplished in an open manner, by placing the mesh through an open incision, or by the endoscopic technique, which involves placing the mesh from within by laparoscopic instruments. The open tension-free procedures can be performed with the use of stitches (according to Lichtenstein or without them (sutureless techniques. Stitching the mesh may cause problems due to maldistribution of tension between the mesh and the patient’s tissues, the occurrence of neuralgia or the development of inflammatory granuloma. Therefore sutureless procedures are increasingly performed. They usually require, besides the use of a mesh patch, also the use of a dart plug made of the same material.Methods. The open tension-free methods of hernia repair have been used at our Department since 1994. The first 77 operations were performed by Lichtenstein technique. The mean postoperative hospital stay was 3.4 days and the mean work restriction period was 3 weeks. In the middle of the year 1995, we shifted to suturless technique. By the end of the year 2000, we had performed 768 operations. The average postoperative hospital stay was 1.2 days and the average recovery time was 10 days.Results. In the first group of 77 hernia repairs performed by the Lichtenstein procedure serious complications were noted in six patients: bleeding in one, long-lasting neuralgia in two, and purulent granuloma, appearing long after discharge from the hospital, in three. There were no recurrences. In the second group of 768 hernia repairs